Science.gov

Sample records for additional samples collected

  1. Automated microorganism Sample Collection Module

    NASA Technical Reports Server (NTRS)

    Gall, L. S.; Graham, M. D.; Umbreit, W.

    1969-01-01

    Modified Gelman Sampler obtains representative sample of microorganism population. Proposed Sample Collection Module is based on direct inoculation of selected solid growth media encased in a cartridge at all times except during inoculation. Cartridge can be handled with no danger of contamination to sample or operator.

  2. Dynamic Method for Identifying Collected Sample Mass

    NASA Technical Reports Server (NTRS)

    Carson, John

    2008-01-01

    G-Sample is designed for sample collection missions to identify the presence and quantity of sample material gathered by spacecraft equipped with end effectors. The software method uses a maximum-likelihood estimator to identify the collected sample's mass based on onboard force-sensor measurements, thruster firings, and a dynamics model of the spacecraft. This makes sample mass identification a computation rather than a process requiring additional hardware. Simulation examples of G-Sample are provided for spacecraft model configurations with a sample collection device mounted on the end of an extended boom. In the absence of thrust knowledge errors, the results indicate that G-Sample can identify the amount of collected sample mass to within 10 grams (with 95-percent confidence) by using a force sensor with a noise and quantization floor of 50 micrometers. These results hold even in the presence of realistic parametric uncertainty in actual spacecraft inertia, center-of-mass offset, and first flexibility modes. Thrust profile knowledge is shown to be a dominant sensitivity for G-Sample, entering in a nearly one-to-one relationship with the final mass estimation error. This means thrust profiles should be well characterized with onboard accelerometers prior to sample collection. An overall sample-mass estimation error budget has been developed to approximate the effect of model uncertainty, sensor noise, data rate, and thrust profile error on the expected estimate of collected sample mass.

  3. Urine sample collection protocols for bioassay samples

    SciTech Connect

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject's body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  4. Urine sample collection protocols for bioassay samples

    SciTech Connect

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject`s body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  5. Collection of Samples for DNA Analysis.

    PubMed

    van Oorschot, Roland A H; Verdon, Timothy J; Ballantyne, Kaye N

    2016-01-01

    Effective sampling of biological material is critical to the ability to acquire DNA profiles of probative value. The main methods of collection are swabbing, tapelifting, or direct excision. This chapter describes the key aspects to consider when applying these methods, in addition to suggested procedures for swabbing and tapelifting. Important issues to be considered, such as exhibit triaging, pre-examination preparation, contamination risk reduction, sample localization, sample identification, and sample prioritization as well as aspects of record keeping, packaging, and storage, are also raised. PMID:27259727

  6. Biopolymers for sample collection, protection, and preservation.

    PubMed

    Sorokulova, Iryna; Olsen, Eric; Vodyanoy, Vitaly

    2015-07-01

    One of the principal challenges in the collection of biological samples from air, water, and soil matrices is that the target agents are not stable enough to be transferred from the collection point to the laboratory of choice without experiencing significant degradation and loss of viability. At present, there is no method to transport biological samples over considerable distances safely, efficiently, and cost-effectively without the use of ice or refrigeration. Current techniques of protection and preservation of biological materials have serious drawbacks. Many known techniques of preservation cause structural damages, so that biological materials lose their structural integrity and viability. We review applications of a novel bacterial preservation process, which is nontoxic and water soluble and allows for the storage of samples without refrigeration. The method is capable of protecting the biological sample from the effects of environment for extended periods of time and then allows for the easy release of these collected biological materials from the protective medium without structural or DNA damage. Strategies for sample collection, preservation, and shipment of bacterial, viral samples are described. The water-soluble polymer is used to immobilize the biological material by replacing the water molecules within the sample with molecules of the biopolymer. The cured polymer results in a solid protective film that is stable to many organic solvents, but quickly removed by the application of the water-based solution. The process of immobilization does not require the use of any additives, accelerators, or plastifiers and does not involve high temperature or radiation to promote polymerization.

  7. Sample collection system for gel electrophoresis

    DOEpatents

    Olivares, Jose A.; Stark, Peter C.; Dunbar, John M.; Hill, Karen K.; Kuske, Cheryl R.; Roybal, Gustavo

    2004-09-21

    An automatic sample collection system for use with an electrophoretic slab gel system is presented. The collection system can be used with a slab gel have one or more lanes. A detector is used to detect particle bands on the slab gel within a detection zone. Such detectors may use a laser to excite fluorescently labeled particles. The fluorescent light emitted from the excited particles is transmitted to low-level light detection electronics. Upon the detection of a particle of interest within the detection zone, a syringe pump is activated, sending a stream of buffer solution across the lane of the slab gel. The buffer solution collects the sample of interest and carries it through a collection port into a sample collection vial.

  8. Asteroid Redirect Mission: EVA and Sample Collection

    NASA Technical Reports Server (NTRS)

    Abell, Paul; Stich, Steve

    2015-01-01

    Asteroid Redirect Mission (ARM) Overview (1) Notional Development Schedule, (2) ARV Crewed Mission Accommodations; Asteroid Redirect Crewed Mission (ARCM) Mission Summary; ARCM Accomplishments; Sample collection/curation plan (1) CAPTEM Requirements; SBAG Engagement Plan

  9. Water sample-collection and distribution system

    NASA Technical Reports Server (NTRS)

    Brooks, R. R.

    1978-01-01

    Collection and distribution system samples water from six designated stations, filtered if desired, and delivers it to various analytical sensors. System may be controlled by Water Monitoring Data Acquisition System or operated manually.

  10. Final Report BW Sample Collection& Preparation Device

    SciTech Connect

    Koopman, R P; Belgrader, P; Meyer, G; Benett, W J; Richards, J B; Hadley, D R; Stratton, P L; Milanovich, F P

    2002-01-31

    The objective of this project was to develop the technique needed to prepare a field collected sample for laboratory analysis and build a portable integrated biological detection instrument with new miniaturized and automated sample purification capabilities. The device will prepare bacterial spores, bacterial vegetative cells, and viral particles for PCR amplification.

  11. Automated Sample collection and Analysis unit

    SciTech Connect

    Latner, Norman; Sanderson, Colin G.; Negro, Vincent C.

    1999-03-31

    Autoramp is an atmospheric radionuclide collection and analysis unit designed for unattended operation. A large volume of air passes through one of 31 filter cartridges which is then moved from a sampling chamber and past a bar code reader, to a shielded enclosure. The collected dust-borne radionuclides are counted with a high resolution germanium gamma-ray detector. An analysis is made and the results are transmitted to a central station that can also remotely control the unit.

  12. 7 CFR 27.25 - Additional samples of cotton; drawing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Additional samples of cotton; drawing. 27.25 Section... CONTAINER REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.25 Additional samples of cotton; drawing. In addition to the samples hereinbefore...

  13. 7 CFR 27.25 - Additional samples of cotton; drawing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Additional samples of cotton; drawing. 27.25 Section... CONTAINER REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.25 Additional samples of cotton; drawing. In addition to the samples hereinbefore...

  14. 7 CFR 27.25 - Additional samples of cotton; drawing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Additional samples of cotton; drawing. 27.25 Section... CONTAINER REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.25 Additional samples of cotton; drawing. In addition to the samples hereinbefore...

  15. 7 CFR 27.25 - Additional samples of cotton; drawing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Additional samples of cotton; drawing. 27.25 Section... CONTAINER REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.25 Additional samples of cotton; drawing. In addition to the samples hereinbefore...

  16. 7 CFR 27.25 - Additional samples of cotton; drawing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Additional samples of cotton; drawing. 27.25 Section... CONTAINER REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.25 Additional samples of cotton; drawing. In addition to the samples hereinbefore...

  17. 5 CFR 179.218 - Additional administrative collection action.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Additional administrative collection action. 179.218 Section 179.218 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS CLAIMS COLLECTION STANDARDS Salary Offset § 179.218 Additional administrative collection...

  18. Automated collection and processing of environmental samples

    DOEpatents

    Troyer, Gary L.; McNeece, Susan G.; Brayton, Darryl D.; Panesar, Amardip K.

    1997-01-01

    For monitoring an environmental parameter such as the level of nuclear radiation, at distributed sites, bar coded sample collectors are deployed and their codes are read using a portable data entry unit that also records the time of deployment. The time and collector identity are cross referenced in memory in the portable unit. Similarly, when later recovering the collector for testing, the code is again read and the time of collection is stored as indexed to the sample collector, or to a further bar code, for example as provided on a container for the sample. The identity of the operator can also be encoded and stored. After deploying and/or recovering the sample collectors, the data is transmitted to a base processor. The samples are tested, preferably using a test unit coupled to the base processor, and again the time is recorded. The base processor computes the level of radiation at the site during exposure of the sample collector, using the detected radiation level of the sample, the delay between recovery and testing, the duration of exposure and the half life of the isotopes collected. In one embodiment, an identity code and a site code are optically read by an image grabber coupled to the portable data entry unit.

  19. 77 FR 67655 - Agency Information Collection Activities; Proposed Collection; Comment Request; Food Additive...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-13

    ... Collection; Comment Request; Food Additive Petitions and Investigational Food Additive Exemptions; Extension... comment in response to the notice. This notice solicits comments on food additive petitions regarding... of information technology. Food Additive Petitions and Investigational Food Additive Exemptions,...

  20. Astronaut John Young photographed collecting lunar samples

    NASA Technical Reports Server (NTRS)

    1972-01-01

    Astronaut John W. Young, commander of the Apollo 16 lunar landing mission, is photographed collecting lunar samples near North Ray crater during the third Apollo 16 extravehicular activity (EVA-3) at the Descartes landing site. This picture was taken by Astronaut Charles M. Duke Jr., lunar module pilot. Young is using the lunar surface rake and a set of tongs. The Lunar Roving Vehicle is parked in the field of large boulders in the background.

  1. Matrix isolation apparatus with extended sample collection capability

    DOEpatents

    Reedy, Gerald T.

    1987-01-01

    A gas-sample collection device provides for the matrix isolation of increased amounts of a sample material for spectrographic analysis from a gas chromatographic separation. The device includes an evacuated sample collection chamber containing a disc-like specular carousel having a generally circular lateral surface upon which the sample is deposited in an inert gas matrix for infrared (IR) spectral analysis. The evacuated sample chamber is mounted in a fixed manner and is coupled to and supports a rotating cryostatic coupler which, in turn, supports the specular carousel within the collection chamber. A rotational drive system connected to the cryostatic coupler provides for its rotational displacement as well as that of the sample collecting carousel. In addition, rotation of the cryostatic coupler effects vertical displacement of the carousel to permit the collection of an extended sample band in a helical configuration on the entire lateral surface of the carousel. The various components of the carousel's angular/linear displacement drive system are located exterior to the cryostatic coupler for easy access and improved operation. The cryostatic coupler includes a 360.degree. rotary union assembly for permitting the delivery of a high pressure working fluid to the cryostatic coupler in a continuous flow manner for maintaining the specular carousel at a low temperature, e.g., 10.degree.-20.degree. K., for improved uninterrupted gas sample collection and analysis.

  2. Urine sampling and collection system optimization and testing

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Geating, J. A.; Koesterer, M. G.

    1975-01-01

    A Urine Sampling and Collection System (USCS) engineering model was developed to provide for the automatic collection, volume sensing and sampling of urine from each micturition. The purpose of the engineering model was to demonstrate verification of the system concept. The objective of the optimization and testing program was to update the engineering model, to provide additional performance features and to conduct system testing to determine operational problems. Optimization tasks were defined as modifications to minimize system fluid residual and addition of thermoelectric cooling.

  3. Designing an enhanced groundwater sample collection system

    SciTech Connect

    Schalla, R.

    1994-10-01

    As part of an ongoing technical support mission to achieve excellence and efficiency in environmental restoration activities at the Laboratory for Energy and Health-Related Research (LEHR), Pacific Northwest Laboratory (PNL) provided guidance on the design and construction of monitoring wells and identified the most suitable type of groundwater sampling pump and accessories for monitoring wells. The goal was to utilize a monitoring well design that would allow for hydrologic testing and reduce turbidity to minimize the impact of sampling. The sampling results of the newly designed monitoring wells were clearly superior to those of the previously installed monitoring wells. The new wells exhibited reduced turbidity, in addition to improved access for instrumentation and hydrologic testing. The variable frequency submersible pump was selected as the best choice for obtaining groundwater samples. The literature references are listed at the end of this report. Despite some initial difficulties, the actual performance of the variable frequency, submersible pump and its accessories was effective in reducing sampling time and labor costs, and its ease of use was preferred over the previously used bladder pumps. The surface seals system, called the Dedicator, proved to be useful accessory to prevent surface contamination while providing easy access for water-level measurements and for connecting the pump. Cost savings resulted from the use of the pre-production pumps (beta units) donated by the manufacturer for the demonstration. However, larger savings resulted from shortened field time due to the ease in using the submersible pumps and the surface seal access system. Proper deployment of the monitoring wells also resulted in cost savings and ensured representative samples.

  4. Collecting Fecal Samples for Microbiome Analyses in Epidemiology Studies

    PubMed Central

    Sinha, Rashmi; Chen, Jun; Amir, Amnon; Vogtmann, Emily; Shi, Jianxin; Inman, Kristin S.; Flores, Roberto; Sampson, Joshua; Knight, Rob; Chia, Nicholas

    2016-01-01

    Background The need to develop valid methods for sampling and analyzing fecal specimens for microbiome studies is increasingly important, especially for large population studies. Methods Some of the most important attributes of any sampling method are reproducibility, stability, and accuracy. We compared seven fecal sampling methods (no additive, RNAlater, 70% ethanol, EDTA, dry swab, and pre/post development fecal occult blood test (FOBT)) using 16S rRNA microbiome profiling in two laboratories. We evaluated nine commonly used microbiome metrics: abundance of 3 phyla, two alpha-diversities, and four beta-diversities. We determined the technical reproducibility, stability at ambient temperature, and accuracy. Results While microbiome profiles showed systematic biases according to sample method and time at ambient temperature, the highest source of variation was between individuals. All collection methods showed high reproducibility. FOBT and RNAlater resulted in the highest stability without freezing for four days. In comparison to no-additive samples, swab, FOBT, and 70% ethanol exhibited the greatest accuracy when immediately frozen. Conclusions Overall, optimal stability and reproducibility was achieved using FOBT, making this a reasonable sample collection method for 16s analysis. Impact Having standardized method of collecting and storing stable fecal samples will allow future investigations into the role of gut microbiota in chronic disease etiology in large population studies. PMID:26604270

  5. Curating NASA's Past, Present, and Future Astromaterial Sample Collections

    NASA Technical Reports Server (NTRS)

    Zeigler, R. A.; Allton, J. H.; Evans, C. A.; Fries, M. D.; McCubbin, F. M.; Nakamura-Messenger, K.; Righter, K.; Zolensky, M.; Stansbery, E. K.

    2016-01-01

    The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC curation) is responsible for curating all of NASA's extraterrestrial samples. JSC presently curates 9 different astromaterials collections in seven different clean-room suites: (1) Apollo Samples (ISO (International Standards Organization) class 6 + 7); (2) Antarctic Meteorites (ISO 6 + 7); (3) Cosmic Dust Particles (ISO 5); (4) Microparticle Impact Collection (ISO 7; formerly called Space-Exposed Hardware); (5) Genesis Solar Wind Atoms (ISO 4); (6) Stardust Comet Particles (ISO 5); (7) Stardust Interstellar Particles (ISO 5); (8) Hayabusa Asteroid Particles (ISO 5); (9) OSIRIS-REx Spacecraft Coupons and Witness Plates (ISO 7). Additional cleanrooms are currently being planned to house samples from two new collections, Hayabusa 2 (2021) and OSIRIS-REx (2023). In addition to the labs that house the samples, we maintain a wide variety of infra-structure facilities required to support the clean rooms: HEPA-filtered air-handling systems, ultrapure dry gaseous nitrogen systems, an ultrapure water system, and cleaning facilities to provide clean tools and equipment for the labs. We also have sample preparation facilities for making thin sections, microtome sections, and even focused ion-beam sections. We routinely monitor the cleanliness of our clean rooms and infrastructure systems, including measurements of inorganic or organic contamination, weekly airborne particle counts, compositional and isotopic monitoring of liquid N2 deliveries, and daily UPW system monitoring. In addition to the physical maintenance of the samples, we track within our databases the current and ever changing characteristics (weight, location, etc.) of more than 250,000 individually numbered samples across our various collections, as well as more than 100,000 images, and countless "analog" records that record the sample processing records of each individual sample. JSC Curation is co-located with JSC

  6. 21 CFR 71.4 - Samples; additional information.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... samples of the color additive, articles used as components thereof, or of the food, drug, or cosmetic in... additive, or articles used as components thereof, or of the food, drug, or cosmetic in which the color... respect to the safety of the color additive or the physical or technical effect it produces. The date...

  7. 21 CFR 71.4 - Samples; additional information.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... samples of the color additive, articles used as components thereof, or of the food, drug, or cosmetic in... additive, or articles used as components thereof, or of the food, drug, or cosmetic in which the color... respect to the safety of the color additive or the physical or technical effect it produces. The date...

  8. 7 CFR 1403.12 - Additional administrative collection action.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Additional administrative collection action. 1403.12 Section 1403.12 Agriculture Regulations of the Department of Agriculture (Continued) COMMODITY CREDIT CORPORATION, DEPARTMENT OF AGRICULTURE GENERAL REGULATIONS AND POLICIES DEBT SETTLEMENT POLICIES...

  9. Collecting live ant specimens (colony sampling).

    PubMed

    Smith, Chris R; Tschinkel, Walter R

    2009-07-01

    Because of the great diversity of ants, it is difficult to give a single protocol for the collection of live specimens. Ant body size can be very small or extremely large; the ants can be hard or soft, sting or spray toxic chemicals, live in the open or in hard-to-reach places; and colony size can range from tens of individuals to millions. Thus, collection techniques must be tailored to each particular species. In particular, caution must always be taken when dealing with stinging species, and symptoms and basic first-aid measures, especially for the treatment of anaphylactic shock, should be reviewed before beginning fieldwork. Nonetheless, many species are collectable as whole colonies. This protocol reviews some basic techniques for collecting ground-nesting species and describes how to collect whole live colonies (with queens), which are necessary for long-term laboratory studies and addressing questions of social organization and ecology. PMID:20147204

  10. Comparison of aquatic macroinvertebrate samples collected using different field methods

    USGS Publications Warehouse

    Lenz, Bernard N.; Miller, Michael A.

    1996-01-01

    Government agencies, academic institutions, and volunteer monitoring groups in the State of Wisconsin collect aquatic macroinvertebrate data to assess water quality. Sampling methods differ among agencies, reflecting the differences in the sampling objectives of each agency. Lack of infor- mation about data comparability impedes data shar- ing among agencies, which can result in duplicated sampling efforts or the underutilization of avail- able information. To address these concerns, com- parisons were made of macroinvertebrate samples collected from wadeable streams in Wisconsin by personnel from the U.S. Geological Survey- National Water Quality Assessment Program (USGS-NAWQA), the Wisconsin Department of Natural Resources (WDNR), the U.S. Department of Agriculture-Forest Service (USDA-FS), and volunteers from the Water Action Volunteer-Water Quality Monitoring Program (WAV). This project was part of the Intergovernmental Task Force on Monitoring Water Quality (ITFM) Wisconsin Water Resources Coordination Project. The numbers, types, and environmental tolerances of the organ- isms collected were analyzed to determine if the four different field methods that were used by the different agencies and volunteer groups provide comparable results. Additionally, this study com- pared the results of samples taken from different locations and habitats within the same streams.

  11. 75 FR 77645 - Agency Information Collection Activities; Proposed Collection; Comment Request; Color Additive...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-13

    ... Collection; Comment Request; Color Additive Certification Requests and Recordkeeping AGENCY: Food and Drug... certification of color additives manufactured for use in foods, drugs, cosmetics or medical devices in the... of information technology. Color Additive Certification Requests and Recordkeeping--21 CFR Part...

  12. Total airborne mold particle sampling: evaluation of sample collection, preparation and counting procedures, and collection devices.

    PubMed

    Godish, Diana; Godish, Thad

    2008-02-01

    This study was conducted to evaluate (i) procedures used to collect, prepare, and count total airborne mold spore/particle concentrations, and (ii) the relative field performance of three commercially available total airborne mold spore/particle sampling devices. Differences between factory and laboratory airflow calibration values of axial fan-driven sampling instruments (used in the study) indicated a need for laboratory calibration using a mass flow meter to ensure that sample results were accurately calculated. An aniline blue-amended Calberla's solution adjusted to a pH of 4.2-4.4 provided good sample mounting/counting results using Dow Corning high vacuum grease, Dow Corning 280A adhesive, and Dow Corning 316 silicone release spray for samples collected using mini-Burkard and Allergenco samplers. Count variability among analysts was most pronounced in 5% counts of relatively low mold particle deposition density samples and trended downward with increased count percentage and particle deposition density. No significant differences were observed among means of 5, 10, and 20% counts and among analysts; a significant interaction effect was observed between analysts' counts and particle deposition densities. Significantly higher mini-Burkard and Air-O-Cell total mold spore/particle counts for 600x vs. 400x (1.9 and 2.3 x higher, respectively), 1000x vs. 600x (1.9 and 2.2 x higher, respectively) and 1000x vs. 400x (3.6 and 4.6 x higher, respectively) comparisons indicated that 1000x magnification counts best quantified total airborne mold spore/particles using light microscopy, and that lower magnification counts may result in unacceptable underreporting of airborne mold spore/particle concentrations. Modest but significantly higher (1.2x) total mold spore concentrations were observed with Allergenco vs. mini-Burkard samples collected in co-located, concurrently operated sampler studies; moderate but significantly higher mini-Burkard count values (1.4x) were

  13. Automatic Collection of Rock and Soil Samples

    NASA Technical Reports Server (NTRS)

    Kyrias, G. M.

    1982-01-01

    Proposed machine would sample rock or soil automatically. Mounted on a wheeled or tracked vehicle, machine positions drill for cut at any angle from horizontal to vertical, moves power head to drive drill into cut, and stores drilled core in a container. New concept may also be useful in terrestrial agricultural and geologic surveys.

  14. 7 CFR 160.22 - Collecting samples; issuing certificates.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... analysis, classification, or grading shall be limited to official inspectors and to such other personnel of... REGULATIONS AND STANDARDS FOR NAVAL STORES Methods of Analysis, Inspection, Sampling and Grading § 160.22 Collecting samples; issuing certificates. The collection of official samples for the purpose of putting...

  15. 7 CFR 160.22 - Collecting samples; issuing certificates.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... analysis, classification, or grading shall be limited to official inspectors and to such other personnel of... REGULATIONS AND STANDARDS FOR NAVAL STORES Methods of Analysis, Inspection, Sampling and Grading § 160.22 Collecting samples; issuing certificates. The collection of official samples for the purpose of putting...

  16. Snow White Trench Prepared for Sample Collection

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The informally named 'Snow White' trench is the source for the next sample to be acquired by NASA's Phoenix Mars Lander for analysis by the wet chemistry lab.

    The Surface Stereo Imager on Phoenix took this shadow-enhanced image of the trench, on the eastern end of Phoenix's work area, on Sol 103, or the 103rd day of the mission, Sept. 8, 2008. The trench is about 23 centimeters (9 inches) wide.

    The wet chemistry lab is part of Phoenix's Microscopy, Electrochemistry and Conductivity suite of instruments.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  17. Organic analysis of ambient samples collected near Tank 241-C-103: Results from samples collected on May 12, 1994

    SciTech Connect

    Clauss, T.W.; Ligotke, M.W.; McVeety, B.D.; Lucke, R.B.; Young, J.S.; McCulloch, M.; Fruchter, J.S.; Goheen, S.C.

    1995-06-01

    This report describes organic analyses results from ambient samples collected both upwind and through the vapor sampling system (VSS) near Hanford waste storage Tank 241-C-103 (referred to as Tank C-103). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed. Quantitative results were obtained for organic compounds. Five organic tentatively identified compounds (TICS) were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and the reported concentrations are semiquantitative estimates. In addition, we looked for the 40 standard TO-14 analytes. We observed 39. Of these, only one was observed above the 2-ppbv calibrated instrument detection limit. Dichloromethane was above the detection limits using both methods, but the result from the TO-14 method is traceable to a standard gas mixture and is considered more accurate. Organic analytes were found only in the sample collected through the VSS, suggesting that these compounds were residual contamination from a previous sampling job. Detailed descriptions of the results appear in the text.

  18. The Challenge of Assimilating Older Data and Samples into Digital Datasets and Sample Collections

    NASA Astrophysics Data System (ADS)

    Leinen, M.

    2015-12-01

    The geosciences are especially dependent on past observations of the planet to understand both processes and planetary history. As digital storage became more inexpensive - and conversion of written and published material to digital format became easier - many of us assumed that existing files of data -- and even notebooks and 'shoeboxes' of data would be assimilated into larger curated datasets. While publications are rapidly becoming available digitally, the data in them, no less data that were not published, are not being integrated into readily available datasets. Negative data, while critical are especially at risk. Samples are even more vulnerable because of the space needed and cost of maintenance. Universities are more frequently being called on to manage the data and collections of faculty who are no longer active or to find other collections that are willing to take them on, in most cases with no additional resources. Examples from datasets and collections maintained by Scripps Institution of Oceanography will be used to illustrate challenges.

  19. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide...

  20. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide...

  1. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide...

  2. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide...

  3. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide...

  4. Scientific guidelines for preservation of samples collected from Mars

    NASA Technical Reports Server (NTRS)

    Gooding, James L. (Editor)

    1990-01-01

    The maximum scientific value of Martian geologic and atmospheric samples is retained when the samples are preserved in the conditions that applied prior to their collection. Any sample degradation equates to loss of information. Based on detailed review of pertinent scientific literature, and advice from experts in planetary sample analysis, number values are recommended for key parameters in the environmental control of collected samples with respect to material contamination, temperature, head-space gas pressure, ionizing radiation, magnetic fields, and acceleration/shock. Parametric values recommended for the most sensitive geologic samples should also be adequate to preserve any biogenic compounds or exobiological relics.

  5. Additional sampling directions improve detection range of wireless radiofrequency probes

    PubMed Central

    Mada, Marius; Carpenter, T. Adrian; Sawiak, Stephen J.; Williams, Guy B.

    2015-01-01

    Purpose While MRI is enhancing our knowledge about the structure and function of the human brain, subject motion remains a problem in many clinical applications. Recently, the use of wireless radiofrequency markers with three one‐dimensional (1D) navigators for prospective correction was demonstrated. This method is restricted in the range of motion that can be corrected, however, because of limited information in the 1D readouts. Methods Here, the limitation of techniques for disambiguating marker locations was investigated. It was shown that including more sampling directions extends the tracking range for head rotations. The efficiency of trading readout resolution for speed was explored. Results Tracking of head rotations was demonstrated from −19.2 to 34.4°, −2.7 to 10.0°, and −60.9 to 70.9° in the x‐, y‐, and z‐directions, respectively. In the presence of excessive head motion, the deviation of marker estimates from SPM8 was reduced by 17.1% over existing three‐projection methods. This was achieved by using an additional seven directions, extending the time needed for readouts by a factor of 3.3. Much of this increase may be circumvented by reducing resolution, without compromising accuracy. Conclusion Including additional sampling directions extends the range in which markers can be used, for patients who move a lot. Magn Reson Med 76:913–918, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. PMID:26418189

  6. CHARACTERIZATION OF CORE SAMPLE COLLECTED FROM THE SALTSTONE DISPOSAL FACILITY

    SciTech Connect

    Cozzi, A.; Duncan, A.

    2010-01-28

    During the month of September 2008, grout core samples were collected from the Saltstone Disposal Facility, Vault 4, cell E. This grout was placed during processing campaigns in December 2007 from Deliquification, Dissolution and Adjustment Batch 2 salt solution. The 4QCY07 Waste Acceptance Criteria sample collected on 11/16/07 represents the salt solution in the core samples. Core samples were retrieved to initiate the historical database of properties of emplaced Saltstone and to demonstrate the correlation between field collected and laboratory prepared samples. Three samples were collected from three different locations. Samples were collected using a two-inch diameter concrete coring bit. In April 2009, the core samples were removed from the evacuated sample container, inspected, transferred to PVC containers, and backfilled with nitrogen. Samples furthest from the wall were the most intact cylindrically shaped cored samples. The shade of the core samples darkened as the depth of coring increased. Based on the visual inspection, sample 3-3 was selected for all subsequent analysis. The density and porosity of the Vault 4 core sample, 1.90 g/cm{sup 3} and 59.90% respectively, were comparable to values achieved for laboratory prepared samples. X-ray diffraction analysis identified phases consistent with the expectations for hydrated Saltstone. Microscopic analysis revealed morphology features characteristic of cementitious materials with fly ash and calcium silicate hydrate gel. When taken together, the results of the density, porosity, x-ray diffraction analysis and microscopic analysis support the conclusion that the Vault 4, Cell E core sample is representative of the expected waste form.

  7. Miniature Blimps for Surveillance and Collection of Samples

    NASA Technical Reports Server (NTRS)

    Jones, Jack

    2004-01-01

    Miniature blimps are under development as robots for use in exploring the thick, cold, nitrogen atmosphere of Saturn's moon, Titan. Similar blimps can also be used for surveillance and collection of biochemical samples in buildings, caves, subways, and other, similar structures on Earth. The widely perceived need for means to thwart attacks on buildings and to mitigate the effects of such attacks has prompted consideration of the use of robots. Relative to rover-type (wheeled) robots that have been considered for such uses, miniature blimps offer the advantage of ability to move through the air in any direction and, hence, to perform tasks that are difficult or impossible for wheeled robots, including climbing stairs and looking through windows. In addition, miniature blimps are expected to have greater range and to cost less, relative to wheeled robots.

  8. Study of Cloud Water Samples Collected over Northern Poland.

    PubMed

    Polkowska, Ż; Błaś, M; Lech, D; Namieśnik, J

    2014-01-01

    The paper gives the results of the first studies on the chemistry of cloud water collected during 3 mo (Aug.-Oct. 2010) in the free atmosphere over the area to the south of the Tri-City (Gdansk-Sopot-Gdynia) conurbation on the Gulf of Gdansk, Poland. Taken from cumulus, stratus, and stratocumulus clouds by means of an aircraft-mounted collector, the water samples were analyzed for the following contaminants: anions (chlorides, fluorides, nitrates, sulfates, and phosphates), cations (lithium, sodium, potassium, ammonium, calcium, and magnesium), and trace metals. In addition, pH values were measured, and the type and composition of suspended particulate matter was determined. We discuss the relationship between the concentration of inorganic ions and the type of cloud from which water was sampled. The chemistry is also likely related to the circulation pattern and inflow of clean air masses from the Baltic Sea. Moreover, a relationship was found between the composition of the samples examined and the location of pollutant emission sources.

  9. A perception and manipulation system for collecting rock samples

    NASA Technical Reports Server (NTRS)

    Choi, T.; Delingette, H.; Deluise, M.; Hsin, Y.; Hebert, M.; Ikeuchi, Katsushi

    1991-01-01

    An important part of a planetary exploration mission is to collect and analyze surface samples. As part of the Carnegie Mellon University Ambler Project, researchers are investigating techniques for collecting samples using a robot arm and a range sensor. The aim of this work is to make the sample collection operation fully autonomous. Described here are the components of the experimental system, including a perception module that extracts objects of interest from range images and produces models of their shapes, and a manipulation module that enables the system to pick up the objects identified by the perception module. The system was tested on a small testbed using natural terrain.

  10. Collecting Ground Samples for Balloon-Borne Instruments

    NASA Technical Reports Server (NTRS)

    Jones, Jack; Zimmerman, Wayne; Wu, Jiunn Jenq

    2009-01-01

    A proposed system in a gondola containing scientific instruments suspended by a balloon over the surface of the Saturn moon Titan would quickly acquire samples of rock or ice from the ground below. Prototypes of a sample-collecting device that would be a major part of the system have been tested under cryogenic and non-cryogenic conditions on Earth. Systems like this one could also be used in non-cryogenic environments on Earth to collect samples of rock, soil, ice, mud, or other ground material from such inaccessible or hazardous locations as sites of suspected chemical spills or biological contamination. The sample-collecting device would be a harpoonlike device that would be connected to the balloon-borne gondola by a tether long enough to reach the ground. The device would be dropped from the gondola to acquire a sample, then would be reeled back up to the gondola, where the sample would be analyzed by the onboard instruments. Each prototype of the sample-collecting device has a sharp front (lower) end, a hollow core for retaining a sample, a spring for holding the sample in the hollow core, and a rear (upper) annular cavity for retaining liquid sample material. Aerodynamic fins at the rear help to keep the front end pointed downward. In tests, these prototype devices were dropped from various heights and used to gather samples of dry sand, moist sand, cryogenic water ice, and warmer water ice.

  11. Air sampling filtration media: Collection efficiency for respirable size-selective sampling

    PubMed Central

    Soo, Jhy-Charm; Monaghan, Keenan; Lee, Taekhee; Kashon, Mike; Harper, Martin

    2016-01-01

    The collection efficiencies of commonly used membrane air sampling filters in the ultrafine particle size range were investigated. Mixed cellulose ester (MCE; 0.45, 0.8, 1.2, and 5 μm pore sizes), polycarbonate (0.4, 0.8, 2, and 5 μm pore sizes), polytetrafluoroethylene (PTFE; 0.45, 1, 2, and 5 μm pore sizes), polyvinyl chloride (PVC; 0.8 and 5 μm pore sizes), and silver membrane (0.45, 0.8, 1.2, and 5 μm pore sizes) filters were exposed to polydisperse sodium chloride (NaCl) particles in the size range of 10–400 nm. Test aerosols were nebulized and introduced into a calm air chamber through a diffusion dryer and aerosol neutralizer. The testing filters (37 mm diameter) were mounted in a conductive polypropylene filter-holder (cassette) within a metal testing tube. The experiments were conducted at flow rates between 1.7 and 11.2 l min−1. The particle size distributions of NaCl challenge aerosol were measured upstream and downstream of the test filters by a scanning mobility particle sizer (SMPS). Three different filters of each type with at least three repetitions for each pore size were tested. In general, the collection efficiency varied with airflow, pore size, and sampling duration. In addition, both collection efficiency and pressure drop increased with decreased pore size and increased sampling flow rate, but they differed among filter types and manufacturer. The present study confirmed that the MCE, PTFE, and PVC filters have a relatively high collection efficiency for challenge particles much smaller than their nominal pore size and are considerably more efficient than polycarbonate and silver membrane filters, especially at larger nominal pore sizes. PMID:26834310

  12. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure for young children wearing diapers, a method for collecting urine samples for analysis of pesticide metabolites is needed. To find a practical method, two possibilities were investigated: (1) analysis of expressed urine from cotton diaper inserts ...

  13. SAMPLE COLLECTION AND HANDLING FOR MICROBIOLOGICAL EXAMINATION OF BIOSOLIDS

    EPA Science Inventory

    The objective of this presentation is to discuss sample collection and handling methods currently in use for detection and enumeration of microorganisms in biosolids and municipal wastewater sludges. Untreated sludges and biosolids are rarely homogeneous and present a challenge ...

  14. The ABN Database: Sampling Strategies for Collection Overlap Studies.

    ERIC Educational Resources Information Center

    Rochester, Maxine K.

    1987-01-01

    Reports the methodology and results of a study which explored the potential of three approaches to sampling the Australian Bibliographic Network (ABN) database files for determining collection overlap among Australian libraries. (Author/CLB)

  15. Salivary testosterone measurements: collecting, storing, and mailing saliva samples.

    PubMed

    Dabbs, J M

    1991-04-01

    Salivary testosterone measurements can be especially useful in field studies, but reliable ways of collecting and handling samples need to be established. Using cotton dental rolls to collect saliva leads to inflated testosterone scores. Sugarfree gum can be used satisfactorily to stimulate saliva among both male and female subjects. Leaving unpreserved saliva samples at room temperature for 2 weeks or mailing them unrefrigerated is satisfactory for male subjects but leads to inflated scores for female subjects.

  16. Hydrodynamic effects in buccal cell DNA sample collection

    NASA Astrophysics Data System (ADS)

    Aidun, C. K.; Sozer, A. C.

    2003-11-01

    Many different methods can be used for collection of biological samples from individuals for DNA profiling purposes. However, blood and buccal cells are the two most popular sources of DNA. In situations where large numbers of samples have to be collected, buccal cell collection methods are the preferred choice because of minimized health risks and ease of collection, transportation, and storage. The normal practice in buccal cell collection is to rub a cotton swab or a piece of paper through the inner check of the subject in order to release the cells and to attach and collect the cells on the cotton or paper fibers. The problem with the current forms of sample collection and storage is that in some cases up to 20% of the samples collected do not result in a DNA profile of adequate quality to be reported by the laboratory without repeated testing. In this study, we consider the mechanics of a small sheet of paper being rubbed on the surface of the inner check. The process is not too different from coating a paper substrate with highly deformable material. The shear field developed between the paper and the fluid adjacent to the cells are estimated based on the available data. The action of the cell release and the cell adherence to the surface will be outlined.

  17. Collection, chemical analysis, and evaluation of coal samples in 1975

    USGS Publications Warehouse

    Swanson, Vernon Emanuel; Medlin, J.H.; Hatch, J.R.; Coleman, S.L.; Wood, G.H.; Woodruff, S.D.; Hildebrand, R.T.

    1976-01-01

    During 1975, the U.S. Geological Survey, in cooperation with other Federal and State agencies, university groups, and private companies, continued its program to augment and refine information on the composition of coal in the United States. This report includes all analytical data on 799 channel samples of coal beds from major operating mines and core holes in 28 States, collected mainly by State Geological Surveys under a cooperative program funded largely by the U.S. Energy Research and Development Administration. For each sample, the U.S. Geological Survey has quantitatively determined the amounts of 24 major, minor, and trace elements (including AI, As, Cd, Cu, F, Hg, Mn, Na, Pb, Se, U, and Zn), and has semiquantitatively determined the concentrations of 15 to 20 additional trace elements (including B, Be, Cr, Ge, Mo, Ni, and V). In addition, the U.S. Bureau of Mines has provided proximate and ultimate analyses, and Btu and forms-of-sulfur determinations on 488 of the samples. Statistical summaries of the data are given for all coal samples in the United States, for coal divided by rank (53 anthracite, 509 bituminous coal, 183 subbituminous coal, and 54 lignite samples), and the arithmetic means, ranges, and geometric means and deviations are given for the coal in each of seven different major coal areas in the United States. For example, the average coal in the United States contains 11.3 percent ash, 10.0 percent moisture, 2.0 percent sulfur, and has 11,180 Btu per pound; of the 10 major oxides determined on the 525?C ash, the average SiO2 content is 38 percent, Al2O3 20 percent, and Na2O 0.67 percent; the average Cd content is 7.3 ppm, Pb 114 ppm, and Zn 151 ppm (range 1 ppm to 6.0 percent). As determined on the raw coal, the average Hg content is 0.18 ppm (range <0.01 to 63.0 ppm), the Se content 4.1 ppm (range <0.1 to 150 ppm), and the U content 1.8 ppm (range <0.2 to 42.9 ppm).

  18. 28 CFR 28.12 - Collection of DNA samples.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... lawfully admitted for permanent residence as defined in 8 CFR 1.1(p). Unless otherwise directed by the... 28 Judicial Administration 1 2013-07-01 2013-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample...

  19. 28 CFR 28.12 - Collection of DNA samples.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... lawfully admitted for permanent residence as defined in 8 CFR 1.1(p). Unless otherwise directed by the... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample...

  20. 28 CFR 28.12 - Collection of DNA samples.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... lawfully admitted for permanent residence as defined in 8 CFR 1.1(p). Unless otherwise directed by the... 28 Judicial Administration 1 2011-07-01 2011-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample...

  1. 28 CFR 28.12 - Collection of DNA samples.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... lawfully admitted for permanent residence as defined in 8 CFR 1.1(p). Unless otherwise directed by the... 28 Judicial Administration 1 2012-07-01 2012-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample...

  2. 28 CFR 28.12 - Collection of DNA samples.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... lawfully admitted for permanent residence as defined in 8 CFR 1.1(p). Unless otherwise directed by the... 28 Judicial Administration 1 2014-07-01 2014-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample...

  3. A direct method for e-cigarette aerosol sample collection.

    PubMed

    Olmedo, Pablo; Navas-Acien, Ana; Hess, Catherine; Jarmul, Stephanie; Rule, Ana

    2016-08-01

    E-cigarette use is increasing in populations around the world. Recent evidence has shown that the aerosol produced by e-cigarettes can contain a variety of toxicants. Published studies characterizing toxicants in e-cigarette aerosol have relied on filters, impingers or sorbent tubes, which are methods that require diluting or extracting the sample in a solution during collection. We have developed a collection system that directly condenses e-cigarette aerosol samples for chemical and toxicological analyses. The collection system consists of several cut pipette tips connected with short pieces of tubing. The pipette tip-based collection system can be connected to a peristaltic pump, a vacuum pump, or directly to an e-cigarette user for the e-cigarette aerosol to flow through the system. The pipette tip-based system condenses the aerosol produced by the e-cigarette and collects a liquid sample that is ready for analysis without the need of intermediate extraction solutions. We tested a total of 20 e-cigarettes from 5 different brands commercially available in Maryland. The pipette tip-based collection system condensed between 0.23 and 0.53mL of post-vaped e-liquid after 150 puffs. The proposed method is highly adaptable, can be used during field work and in experimental settings, and allows collecting aerosol samples from a wide variety of e-cigarette devices, yielding a condensate of the likely exact substance that is being delivered to the lungs.

  4. A direct method for e-cigarette aerosol sample collection.

    PubMed

    Olmedo, Pablo; Navas-Acien, Ana; Hess, Catherine; Jarmul, Stephanie; Rule, Ana

    2016-08-01

    E-cigarette use is increasing in populations around the world. Recent evidence has shown that the aerosol produced by e-cigarettes can contain a variety of toxicants. Published studies characterizing toxicants in e-cigarette aerosol have relied on filters, impingers or sorbent tubes, which are methods that require diluting or extracting the sample in a solution during collection. We have developed a collection system that directly condenses e-cigarette aerosol samples for chemical and toxicological analyses. The collection system consists of several cut pipette tips connected with short pieces of tubing. The pipette tip-based collection system can be connected to a peristaltic pump, a vacuum pump, or directly to an e-cigarette user for the e-cigarette aerosol to flow through the system. The pipette tip-based system condenses the aerosol produced by the e-cigarette and collects a liquid sample that is ready for analysis without the need of intermediate extraction solutions. We tested a total of 20 e-cigarettes from 5 different brands commercially available in Maryland. The pipette tip-based collection system condensed between 0.23 and 0.53mL of post-vaped e-liquid after 150 puffs. The proposed method is highly adaptable, can be used during field work and in experimental settings, and allows collecting aerosol samples from a wide variety of e-cigarette devices, yielding a condensate of the likely exact substance that is being delivered to the lungs. PMID:27200479

  5. 78 FR 51265 - 30-Day Notice of Proposed Information Collection: Application for Additional Visa Pages or...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-20

    ... Notice of Proposed Information Collection: Application for Additional Visa Pages or Miscellaneous...: Title of Information Collection: Application for Additional Visa Pages or Miscellaneous Passport... applies for the addition of visa pages to that passport, the Department must confirm the...

  6. Methods for collection and analysis of water samples

    USGS Publications Warehouse

    Rainwater, Frank Hays; Thatcher, Leland Lincoln

    1960-01-01

    This manual contains methods used by the U.S. Geological Survey to collect, preserve, and analyze water samples. Throughout, the emphasis is on obtaining analytical results that accurately describe the chemical composition of the water in situ. Among the topics discussed are selection of sampling sites, frequency of sampling, field equipment, preservatives and fixatives, analytical techniques of water analysis, and instruments. Seventy-seven laboratory and field procedures are given for determining fifty-three water properties.

  7. On the improvement of blood sample collection at clinical laboratories

    PubMed Central

    2014-01-01

    Background Blood samples are usually collected daily from different collection points, such hospitals and health centers, and transported to a core laboratory for testing. This paper presents a project to improve the collection routes of two of the largest clinical laboratories in Spain. These routes must be designed in a cost-efficient manner while satisfying two important constraints: (i) two-hour time windows between collection and delivery, and (ii) vehicle capacity. Methods A heuristic method based on a genetic algorithm has been designed to solve the problem of blood sample collection. The user enters the following information for each collection point: postal address, average collecting time, and average demand (in thermal containers). After implementing the algorithm using C programming, this is run and, in few seconds, it obtains optimal (or near-optimal) collection routes that specify the collection sequence for each vehicle. Different scenarios using various types of vehicles have been considered. Unless new collection points are added or problem parameters are changed substantially, routes need to be designed only once. Results The two laboratories in this study previously planned routes manually for 43 and 74 collection points, respectively. These routes were covered by an external carrier company. With the implementation of this algorithm, the number of routes could be reduced from ten to seven in one laboratory and from twelve to nine in the other, which represents significant annual savings in transportation costs. Conclusions The algorithm presented can be easily implemented in other laboratories that face this type of problem, and it is particularly interesting and useful as the number of collection points increases. The method designs blood collection routes with reduced costs that meet the time and capacity constraints of the problem. PMID:24406140

  8. 21 CFR 71.4 - Samples; additional information.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... respect to the safety of the color additive or the physical or technical effect it produces. The date used for computing the 90-day limit for the purposes of section 721(d)(1) of the act shall be moved...

  9. 21 CFR 71.4 - Samples; additional information.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... respect to the safety of the color additive or the physical or technical effect it produces. The date used for computing the 90-day limit for the purposes of section 721(d)(1) of the act shall be moved...

  10. 52 additional reference population samples for the 55 AISNP panel.

    PubMed

    Pakstis, Andrew J; Haigh, Eva; Cherni, Lotfi; ElGaaied, Amel Ben Ammar; Barton, Alison; Evsanaa, Baigalmaa; Togtokh, Ariunaa; Brissenden, Jane; Roscoe, Janet; Bulbul, Ozlem; Filoglu, Gonul; Gurkan, Cemal; Meiklejohn, Kelly A; Robertson, James M; Li, Cai-Xia; Wei, Yi-Liang; Li, Hui; Soundararajan, Usha; Rajeevan, Haseena; Kidd, Judith R; Kidd, Kenneth K

    2015-11-01

    Ancestry inference for a person using a panel of SNPs depends on the variation of frequencies of those SNPs around the world and the amount of reference data available for calculation/comparison. The Kidd Lab panel of 55 AISNPs has been incorporated in commercial kits by both Life Technologies and Illumina for massively parallel sequencing. Therefore, a larger set of reference populations will be useful for researchers using those kits. We have added reference population allele frequencies for 52 population samples to the 73 previously entered so that there are now allele frequencies publicly available in ALFRED and FROG-kb for a total of 125 population samples. PMID:26355664

  11. APOLLO 12: C.Conrad Jr. collects geological samples

    NASA Technical Reports Server (NTRS)

    1974-01-01

    APOLLO 12: 'Pete' Conrad collects samples from the lunar surface, while at the same time adjusting to, and remarking on, the working conditions. From the film documentary 'APOLLO 12: 'Pinpoint for Science'', part of a documentary series on the APOLLO missions made in the early '70's and narrated by Burgess Meredith. APOLLO 12: Second manned lunar landing and return with Charles 'Pete' Conrad, Jr., Richard F. Gordon, and Alan F. Bean. Landed in the Ocean of Storms on November 19, 1969; deployed television camera and ALSEP experiments; two EVA's performed; collected core samples and lunar materials; photographed and retrieved parts from surveyor 3 spacecraft. Mission duration 244hrs 36min 24sec

  12. Apparatus and process for collection of gas and vapor samples

    DOEpatents

    Jackson, Dennis G.; Peterson, Kurt D.; Riha, Brian D.

    2008-04-01

    A gas sampling apparatus and process is provided in which a standard crimping tool is modified by an attached collar. The collar permits operation of the crimping tool while also facilitating the introduction of a supply of gas to be introduced into a storage vial. The introduced gas supply is used to purge ambient air from a collection chamber and an interior of the sample vial. Upon completion of the purging operation, the vial is sealed using the crimping tool.

  13. Macroinvertebrate community sample collection methods and data collected from Sand Creek and Medano Creek, Great Sand Dunes National Park and Preserve, Colorado, 2005–07

    USGS Publications Warehouse

    Ford, Morgan A.; Zuellig, Robert E.; Walters, David M.; Bruce, James F.

    2016-01-01

    This report provides a table of site descriptions, sample information, and semiquantitative aquatic macroinvertebrate data from 105 samples collected between 2005 and 2007 from 7 stream sites within the Sand Creek and Medano Creek watersheds in Great Sand Dunes National Park and Preserve, Saguache County, Colorado. Additionally, a short description of sample collection methods and laboratory sample processing procedures is presented. These data were collected in anticipation of assessing the potential effects of fish toxicants on macroinvertebrates.

  14. Macroinvertebrate community sample collection methods and data collected from Sand Creek and Medano Creek, Great Sand Dunes National Park and Preserve, Colorado, 2005–07

    USGS Publications Warehouse

    Ford, Morgan A.; Zuellig, Robert E.; Walters, David M.; Bruce, James F.

    2016-08-11

    This report provides a table of site descriptions, sample information, and semiquantitative aquatic macroinvertebrate data from 105 samples collected between 2005 and 2007 from 7 stream sites within the Sand Creek and Medano Creek watersheds in Great Sand Dunes National Park and Preserve, Saguache County, Colorado. Additionally, a short description of sample collection methods and laboratory sample processing procedures is presented. These data were collected in anticipation of assessing the potential effects of fish toxicants on macroinvertebrates.

  15. Assembly for collecting samples for purposes of identification or analysis and method of use

    DOEpatents

    Thompson, Cyril V [Knoxville, TN; Smith, Rob R [Knoxville, TN

    2010-02-02

    An assembly and an associated method for collecting a sample of material desired to be characterized with diagnostic equipment includes or utilizes an elongated member having a proximal end with which the assembly is manipulated by a user and a distal end. In addition, a collection tip which is capable of being placed into contact with the material to be characterized is supported upon the distal end. The collection tip includes a body of chemically-inert porous material for binding a sample of material when the tip is placed into contact with the material and thereby holds the sample of material for subsequent introduction to the diagnostic equipment.

  16. 78 FR 77119 - Proposed Information Collection Request; Comment Request; Regulation of Fuels and Fuel Additives...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-20

    ... AGENCY Proposed Information Collection Request; Comment Request; Regulation of Fuels and Fuel Additives: 2011 Renewable Fuel Standards-- Petition for International Aggregate Compliance Approach AGENCY... to submit an information collection request (ICR), ``Regulation of Fuels and Fuel Additives:...

  17. Experimental Design for the INL Sample Collection Operational Test

    SciTech Connect

    Amidan, Brett G.; Piepel, Gregory F.; Matzke, Brett D.; Filliben, James J.; Jones, Barbara

    2007-12-13

    This document describes the test events and numbers of samples comprising the experimental design that was developed for the contamination, decontamination, and sampling of a building at the Idaho National Laboratory (INL). This study is referred to as the INL Sample Collection Operational Test. Specific objectives were developed to guide the construction of the experimental design. The main objective is to assess the relative abilities of judgmental and probabilistic sampling strategies to detect contamination in individual rooms or on a whole floor of the INL building. A second objective is to assess the use of probabilistic and Bayesian (judgmental + probabilistic) sampling strategies to make clearance statements of the form “X% confidence that at least Y% of a room (or floor of the building) is not contaminated. The experimental design described in this report includes five test events. The test events (i) vary the floor of the building on which the contaminant will be released, (ii) provide for varying or adjusting the concentration of contaminant released to obtain the ideal concentration gradient across a floor of the building, and (iii) investigate overt as well as covert release of contaminants. The ideal contaminant gradient would have high concentrations of contaminant in rooms near the release point, with concentrations decreasing to zero in rooms at the opposite end of the building floor. For each of the five test events, the specified floor of the INL building will be contaminated with BG, a stand-in for Bacillus anthracis. The BG contaminant will be disseminated from a point-release device located in the room specified in the experimental design for each test event. Then judgmental and probabilistic samples will be collected according to the pre-specified sampling plan. Judgmental samples will be selected based on professional judgment and prior information. Probabilistic samples will be selected in sufficient numbers to provide desired confidence

  18. The World of Hidden Biases: From Collection to Sample Processing

    NASA Astrophysics Data System (ADS)

    Maurette, Michel

    Any study of micrometeorites involves a variety of biases, which start right away during their collection, and which have not been suffciently publicized. This section deals with the astonishing folklore of these biases. We shall question whether major differences observed between Antarctic micrometeorites and stratospheric micrometeorites could reflect kinds of complementary biases between the two collections of micrometeorites. Astonishingly, some of them would converge to enrich the SMMs collection in the most fine-grained fluffy dust particles accreted by the Earth. They might be possibly the most primitive material accreted by the Earth. But they would not give a representative sampling of the bulk micrometeorite flux, which is best obtained with the new Concordia micrometeorites collected in central Antarctica. For a change, biases developing around a small metallic plate flying at ~200m/sec in the stratosphere turned out to be quite helpful!

  19. 75 FR 43989 - Agency Information Collection Activities; Proposed Collection; Comment Request; Sample Collection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-27

    ... HUMAN SERVICES Food and Drug Administration Agency Information Collection Activities; Proposed... involves the use of genome-wide analyses to identify genes with altered expression or activation as a... variations associated with the ADEs reported. If this project identifies definite genotype...

  20. Collection, isolation, and flow cytometric analysis of human endocervical samples.

    PubMed

    Juno, Jennifer A; Boily-Larouche, Genevieve; Lajoie, Julie; Fowke, Keith R

    2014-07-06

    Despite the public health importance of mucosal pathogens (including HIV), relatively little is known about mucosal immunity, particularly at the female genital tract (FGT). Because heterosexual transmission now represents the dominant mechanism of HIV transmission, and given the continual spread of sexually transmitted infections (STIs), it is critical to understand the interplay between host and pathogen at the genital mucosa. The substantial gaps in knowledge around FGT immunity are partially due to the difficulty in successfully collecting and processing mucosal samples. In order to facilitate studies with sufficient sample size, collection techniques must be minimally invasive and efficient. To this end, a protocol for the collection of cervical cytobrush samples and subsequent isolation of cervical mononuclear cells (CMC) has been optimized. Using ex vivo flow cytometry-based immunophenotyping, it is possible to accurately and reliably quantify CMC lymphocyte/monocyte population frequencies and phenotypes. This technique can be coupled with the collection of cervical-vaginal lavage (CVL), which contains soluble immune mediators including cytokines, chemokines and anti-proteases, all of which can be used to determine the anti- or pro-inflammatory environment in the vagina.

  1. Collection, isolation, and flow cytometric analysis of human endocervical samples.

    PubMed

    Juno, Jennifer A; Boily-Larouche, Genevieve; Lajoie, Julie; Fowke, Keith R

    2014-01-01

    Despite the public health importance of mucosal pathogens (including HIV), relatively little is known about mucosal immunity, particularly at the female genital tract (FGT). Because heterosexual transmission now represents the dominant mechanism of HIV transmission, and given the continual spread of sexually transmitted infections (STIs), it is critical to understand the interplay between host and pathogen at the genital mucosa. The substantial gaps in knowledge around FGT immunity are partially due to the difficulty in successfully collecting and processing mucosal samples. In order to facilitate studies with sufficient sample size, collection techniques must be minimally invasive and efficient. To this end, a protocol for the collection of cervical cytobrush samples and subsequent isolation of cervical mononuclear cells (CMC) has been optimized. Using ex vivo flow cytometry-based immunophenotyping, it is possible to accurately and reliably quantify CMC lymphocyte/monocyte population frequencies and phenotypes. This technique can be coupled with the collection of cervical-vaginal lavage (CVL), which contains soluble immune mediators including cytokines, chemokines and anti-proteases, all of which can be used to determine the anti- or pro-inflammatory environment in the vagina. PMID:25045942

  2. Variability of collagen crosslinks: impact of sample collection period

    NASA Technical Reports Server (NTRS)

    Smith, S. M.; Dillon, E. L.; DeKerlegand, D. E.; Davis-Street, J. E.

    2004-01-01

    Because of the variability of collagen crosslinks, their use as markers for bone resorption is often criticized. We hypothesized that the variability could be reduced by collecting urine for 24 hours (or longer) instead of using single voids, and by not normalizing to creatinine. Urine samples were collected from 22 healthy subjects during two or more 24-hour periods. Each 24-hour pool and each 2nd void of the day were analyzed for N-telopeptide (NTX), pyridinium (PYD), and deoxypyridinoline (DPD) crosslinks. Data were analyzed by using linear regression. For NTX, R2 for the two, 2nd-void samples (n = 38) was 0.55, whereas R2 for the two 24-hour pools was 0.51 or 0.52, expressed per day or per creatinine. For PYD and DPD, R2 for the 2nd-void samples was 0.26 and 0.18, R2 for the 24-hour pools expressed per day was 0.58 and 0.74, and R2 for the 24-hour pools expressed per creatinine was 0.65 and 0.76, respectively. Regression of the 2nd void and the corresponding 24-hour pool, expressed per day, yielded R2 = 0.19, 0.19, and 0.08, for NTX, PYD, and DPD, respectively (n = 76 each). For the 2nd-void sample and its corresponding 24-hour pool, expressed per creatinine, R2 = 0.24, 0.33, and 0.08, respectively. In a separate study, the coefficient of variation for NTX was reduced (P < 0.05) when data from more than one 24-hour collection were combined. Thus, the variability inherent in crosslink determinations can be reduced by collecting urine for longer periods. In research studies, the high variability of single-void collections, compounded by creatinine normalization, may alter or obscure findings.

  3. Collection of Stratospheric Samples using Balloon-Borne Payload System

    NASA Astrophysics Data System (ADS)

    Prakash, Ajin; Safonova, Margarita; Murthy, Jayant; Sreejith, A. G.; Kumble, Sheshashayi; Mathew, Joice; Sarpotdar, Mayuresh; Kj, Nirmal; Suresh, Ambily; Chakravortty, Dipshikha; Rangarajan, Annapoorni

    2016-07-01

    Earth's atmosphere at stratospheric altitudes contains dust particles from soil lifted by weather, volcanic dust, man-made aerosols, IDP (Interplanetary Dust Particles) - remnants of comets and asteroids, and even interstellar dust. Satellite observations suggest that approximately 100--300 tons of cosmic dust enter Earth's atmosphere every day. However, very little is known about the microbial life in the upper atmosphere, where conditions are very much similar to that on Mars and possibly on some exoplanets. Stratosphere provides a good opportunity to study the existence or survival of biological life in these conditions. Despite the importance of this topic to astrobiology, stratospheric microbial diversity/survival remains largely unexplored, probably due to significant difficulties in the access and ensuring the absence of contamination of the samples. To conduct a detailed study into this, we are developing the balloon-borne payload system SAMPLE (Stratospheric Altitude Microbiology Probe for Life Existence) to collect dust samples from stratosphere and bring them in an hygienic and uncontaminated manner to a suitable laboratory environment, where further study will be conducted to establish the possibility of microbial life in the upper atmosphere. This balloon-borne payload system will rise through the atmosphere till it reaches an altitude of about 25-30 km above sea level. The payload consists of detachable pre-sterilized sampling chambers designed to collect and contain the dust samples and get them back to the surface without contamination during the flight, a microprocessor and a controller which will determine the altitude of the payload system to actively monitor the opening and closing of the sample collection chambers. For contamination control, we will have two extra chambers, one of which will fly but not open, and one will remain closed on the ground. Other onboard devices include environmental sensors, GPS tracking devices, cameras to monitor

  4. Fluid sample collection and distribution system. [qualitative analysis of aqueous samples from several points

    NASA Technical Reports Server (NTRS)

    Brooks, R. L. (Inventor)

    1979-01-01

    A multipoint fluid sample collection and distribution system is provided wherein the sample inputs are made through one or more of a number of sampling valves to a progressive cavity pump which is not susceptible to damage by large unfiltered particles. The pump output is through a filter unit that can provide a filtered multipoint sample. An unfiltered multipoint sample is also provided. An effluent sample can be taken and applied to a second progressive cavity pump for pumping to a filter unit that can provide one or more filtered effluent samples. The second pump can also provide an unfiltered effluent sample. Means are provided to periodically back flush each filter unit without shutting off the whole system.

  5. Device for collecting and analyzing matrix-isolated samples

    DOEpatents

    Reedy, Gerald T.

    1979-01-01

    A gas-sample collection device is disclosed for matrix isolation of individual gas bands from a gas chromatographic separation and for presenting these distinct samples for spectrometric examination. The device includes a vacuum chamber containing a rotatably supported, specular carrousel having a number of external, reflecting surfaces around its axis of rotation for holding samples. A gas inlet is provided for depositing sample and matrix material on the individual reflecting surfaces maintained at a sufficiently low temperature to cause solidification. Two optical windows or lenses are installed in the vacuum chamber walls for transmitting a beam of electromagnetic radiation, for instance infrared light, through a selected sample. Positioned within the chamber are two concave mirrors, the first aligned to receive the light beam from one of the lenses and focus it to the sample on one of the reflecting surfaces of the carrousel. The second mirror is aligned to receive reflected light from that carrousel surface and to focus it outwardly through the second lens. The light beam transmitted from the sample is received by a spectrometer for determining absorption spectra.

  6. Experimental and Sampling Design for the INL-2 Sample Collection Operational Test

    SciTech Connect

    Piepel, Gregory F.; Amidan, Brett G.; Matzke, Brett D.

    2009-02-16

    This report describes the experimental and sampling design developed to assess sampling approaches and methods for detecting contamination in a building and clearing the building for use after decontamination. An Idaho National Laboratory (INL) building will be contaminated with BG (Bacillus globigii, renamed Bacillus atrophaeus), a simulant for Bacillus anthracis (BA). The contamination, sampling, decontamination, and re-sampling will occur per the experimental and sampling design. This INL-2 Sample Collection Operational Test is being planned by the Validated Sampling Plan Working Group (VSPWG). The primary objectives are: 1) Evaluate judgmental and probabilistic sampling for characterization as well as probabilistic and combined (judgment and probabilistic) sampling approaches for clearance, 2) Conduct these evaluations for gradient contamination (from low or moderate down to absent or undetectable) for different initial concentrations of the contaminant, 3) Explore judgment composite sampling approaches to reduce sample numbers, 4) Collect baseline data to serve as an indication of the actual levels of contamination in the tests. A combined judgmental and random (CJR) approach uses Bayesian methodology to combine judgmental and probabilistic samples to make clearance statements of the form "X% confidence that at least Y% of an area does not contain detectable contamination” (X%/Y% clearance statements). The INL-2 experimental design has five test events, which 1) vary the floor of the INL building on which the contaminant will be released, 2) provide for varying the amount of contaminant released to obtain desired concentration gradients, and 3) investigate overt as well as covert release of contaminants. Desirable contaminant gradients would have moderate to low concentrations of contaminant in rooms near the release point, with concentrations down to zero in other rooms. Such gradients would provide a range of contamination levels to challenge the sampling

  7. Plume Collection Strategies for Icy World Sample Return

    NASA Technical Reports Server (NTRS)

    Neveu, M.; Glavin, D. P.; Tsou, P.; Anbar, A. D.; Williams, P.

    2015-01-01

    Three icy worlds in the solar system display evidence of pluming activity. Water vapor and ice particles emanate from cracks near the south pole of Saturn's moon Enceladus. The plume gas contains simple hydrocarbons that could be fragments of larger, more complex organics. More recently, observations using the Hubble and Herschel space telescopes have hinted at transient water vapor plumes at Jupiter's moon Europa and the dwarf planet Ceres. Plume materials may be ejected directly from possible sub-surface oceans, at least on Enceladus. In such oceans, liquid water, organics, and energy may co-exist, making these environments habitable. The venting of habitable ocean material into space provides a unique opportunity to capture this material during a relatively simple flyby mission and return it to Earth. Plume collection strategies should enable investigations of evidence for life in the returned samples via laboratory analyses of the structure, distribution, isotopic composition, and chirality of the chemical components (including biomolecules) of plume materials. Here, we discuss approaches for the collection of dust and volatiles during flybys through Enceladus' plume, based on Cassini results and lessons learned from the Stardust comet sample return mission. We also highlight areas where sample collector and containment technology development and testing may be needed for future plume sample return missions.

  8. Apollo 17 Astronaut Harrison Schmitt Collects Lunar Rock Samples

    NASA Technical Reports Server (NTRS)

    1972-01-01

    In this Apollo 17 onboard photo, Lunar Module pilot Harrison H. Schmitt collects rock samples from a huge boulder near the Valley of Tourus-Littrow on the lunar surface. The seventh and last manned lunar landing and return to Earth mission, the Apollo 17, carrying a crew of three astronauts: Schmitt; Mission Commander Eugene A. Cernan; and Command Module pilot Ronald E. Evans, lifted off on December 7, 1972 from the Kennedy Space Flight Center (KSC). Scientific objectives of the Apollo 17 mission included geological surveying and sampling of materials and surface features in a preselected area of the Taurus-Littrow region, deploying and activating surface experiments, and conducting in-flight experiments and photographic tasks during lunar orbit and transearth coast (TEC). These objectives included: Deployed experiments such as the Apollo lunar surface experiment package (ALSEP) with a Heat Flow experiment, Lunar seismic profiling (LSP), Lunar surface gravimeter (LSG), Lunar atmospheric composition experiment (LACE) and Lunar ejecta and meteorites (LEAM). The mission also included Lunar Sampling and Lunar orbital experiments. Biomedical experiments included the Biostack II Experiment and the BIOCORE experiment. The mission marked the longest Apollo mission, 504 hours, and the longest lunar surface stay time, 75 hours, which allowed the astronauts to conduct an extensive geological investigation. They collected 257 pounds (117 kilograms) of lunar samples with the use of the Marshall Space Flight Center designed Lunar Roving Vehicle (LRV). The mission ended on December 19, 1972

  9. Predicting species distributions from samples collected along roadsides.

    PubMed

    McCarthy, Kyle P; Fletcher, Robert J; Rota, Christopher T; Hutto, Richard L

    2012-02-01

    Predictive models of species distributions are typically developed with data collected along roads. Roadside sampling may provide a biased (nonrandom) sample; however, it is currently unknown whether roadside sampling limits the accuracy of predictions generated by species distribution models. We tested whether roadside sampling affects the accuracy of predictions generated by species distribution models by using a prospective sampling strategy designed specifically to address this issue. We built models from roadside data and validated model predictions at paired locations on unpaved roads and 200 m away from roads (off road), spatially and temporally independent from the data used for model building. We predicted species distributions of 15 bird species on the basis of point-count data from a landbird monitoring program in Montana and Idaho (U.S.A.). We used hierarchical occupancy models to account for imperfect detection. We expected predictions of species distributions derived from roadside-sampling data would be less accurate when validated with data from off-road sampling than when it was validated with data from roadside sampling and that model accuracy would be differentially affected by whether species were generalists, associated with edges, or associated with interior forest. Model performance measures (kappa, area under the curve of a receiver operating characteristic plot, and true skill statistic) did not differ between model predictions of roadside and off-road distributions of species. Furthermore, performance measures did not differ among edge, generalist, and interior species, despite a difference in vegetation structure along roadsides and off road and that 2 of the 15 species were more likely to occur along roadsides. If the range of environmental gradients is surveyed in roadside-sampling efforts, our results suggest that surveys along unpaved roads can be a valuable, unbiased source of information for species distribution models. PMID:22010858

  10. Appendix C. Collection of Samples for Chemical Agent Analysis

    SciTech Connect

    Koester, C; Thompson, C; Doerr, T; Scripsick, R

    2005-09-23

    This chapter describes procedures for the collection and analysis of samples of various matrices for the purpose of determining the presence of chemical agents in a civilian setting. This appendix is intended to provide the reader with sufficient information to make informed decisions about the sampling and analysis process and to suggest analytical strategies that might be implemented by the scientists performing sampling and analysis. This appendix is not intended to be used as a standard operating procedure to provide detailed instructions as to how trained scientists should handle samples. Chemical agents can be classified by their physical and chemical properties. Table 1 lists the chemical agents considered by this report. In selecting sampling and analysis methods, we have considered procedures proposed by the Organization for Prohibition of Chemical Weapons (OPCW), the U. S. Environmental Protection Agency (EPA), and peer-reviewed scientific literature. EPA analytical methods are good resources describing issues of quality assurance with respect to chain-of-custody, sample handling, and quality control requirements.

  11. Lunar Samples: Apollo Collection Tools, Curation Handling, Surveyor III and Soviet Luna Samples

    NASA Technical Reports Server (NTRS)

    Allton, J.H.

    2009-01-01

    The 6 Apollo missions that landed on the lunar surface returned 2196 samples comprised of 382 kg. The 58 samples weighing 21.5 kg collected on Apollo 11 expanded to 741 samples weighing 110.5 kg by the time of Apollo 17. The main goal on Apollo 11 was to obtain some material and return it safely to Earth. As we gained experience, the sampling tools and a more specific sampling strategy evolved. A summary of the sample types returned is shown in Table 1. By year 1989, some statistics on allocation by sample type were compiled [2]. The "scientific interest index" is based on the assumption that the more allocations per gram of sample, the higher the scientific interest. It is basically a reflection of the amount of diversity within a given sample type. Samples were also set aside for biohazard testing. The samples set aside and used for biohazard testing were represen-tative, as opposed to diverse. They tended to be larger and be comprised of less scientifically valuable mate-rial, such as dust and debris in the bottom of sample containers.

  12. 78 FR 79009 - Proposed Information Collection; Radiation Sampling and Exposure Records (Pertains to Underground...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-27

    ... Safety and Health Administration Proposed Information Collection; Radiation Sampling and Exposure Records... collection for updating Radiation Sampling and Exposure Records. DATES: All comments must be postmarked or... provisions for the Proposed Information Collection Request, Radiation Sampling and Exposure Records. MSHA...

  13. New additions to the National Plant Germplasm System's Beta collection: Southern Morocco collection

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The USDA Agricultural Research Service’s National Plant Germplasm System’s (NPGS) Beta collection is comprised of 2,541 accessions from 14 species. The largest number of accessions is from Beta vulgaris ssp. vulgaris, (domesticated beet crops – table, leaf (Swiss chard), fodder and, primarily, sugar...

  14. Tritium concentrations of blood samples collected throughout Japan

    SciTech Connect

    Hisamatsu, Shun`ichi; Takizawa, Yukio; Inoue, Yoshikazu

    1995-04-01

    Tritium concentrations were measured for blood samples collected from 20 cities throughout Japan during 1989-1990. The mean {sup 3}H concentration was found to be 1.4 {plus_minus} 0.4 Bq L{sup -1} and 1.0 {plus_minus} 0.4 Bq L{sup -1} (combustion water) for free water {sup 3}H and organically-bound {sup 3}H, respectively, excluding the abnormally high data of one city. The organically-bound {sup 3}H contents clearly depended on the latitudes of sampling locations, although the free water {sup 3}H concentrations showed no correlation with the latitudes. Organically-bound {sup 3}H is considered to be more suitable than free water {sup 3}H as an indicator of long time {sup 3}H exposure to human.

  15. A new device for collecting time-integrated water samples from springs and surface water bodies

    USGS Publications Warehouse

    Panno, S.V.; Krapac, I.G.; Keefer, D.A.

    1998-01-01

    A new device termed the 'seepage sampler' was developed to collect representative water samples from springs, streams, and other surface-water bodies. The sampler collects composite, time-integrated water samples over short (hours) or extended (weeks) periods without causing significant changes to the chemical composition of the samples. The water sample within the sampler remains at the ambient temperature of the water body and does not need to be cooled. Seepage samplers are inexpensive to construct and easy to use. A sampling program of numerous springs and/or streams can be designed at a relatively low cost through the use of these samplers. Transient solutes migrating through such flow systems, potentially unnoticed by periodic sampling, may be detected. In addition, the mass loading of solutes (e.g., agrichemicals) may be determined when seepage samplers are used in conjunction with discharge measurements.

  16. Planning Considerations Related to Collecting and Analyzing Samples of the Martian Soils

    NASA Technical Reports Server (NTRS)

    Liu, Yang; Mellon, Mike T.; Ming, Douglas W.; Morris, Richard V.; Noble, Sarah K.; Sullivan, Robert J.; Taylor, Lawrence A.; Beaty, David W.

    2014-01-01

    The Mars Sample Return (MSR) End-to-End International Science Analysis Group (E2E-iSAG [1]) established scientific objectives associ-ated with Mars returned-sample science that require the return and investigation of one or more soil samples. Soil is defined here as loose, unconsolidated materials with no implication for the presence or absence of or-ganic components. The proposed Mars 2020 (M-2020) rover is likely to collect and cache soil in addition to rock samples [2], which could be followed by future sample retrieval and return missions. Here we discuss key scientific consid-erations for sampling and caching soil samples on the proposed M-2020 rover, as well as the state in which samples would need to be preserved when received by analysts on Earth. We are seeking feedback on these draft plans as input to mission requirement formulation. A related planning exercise on rocks is reported in an accompanying abstract [3].

  17. 75 FR 62404 - Agency Information Collection Activities; Proposed Collection; Comment Request; Additional...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-08

    ...-counter (OTC) drugs as generally recognized as safe and effective and not misbranded. DATES: Submit either... additional criteria and procedures for classifying OTC drugs as generally recognized as safe and effective and not misbranded (2002 TEA final rule). The regulations in Sec. 330.14 state that OTC drug...

  18. Extravehicular Activity Asteroid Exploration and Sample Collection Capability

    NASA Technical Reports Server (NTRS)

    Scoville, Zebulon; Sipila, Stephanie; Bowie, Jonathan

    2014-01-01

    NASA's Asteroid Redirect Crewed Mission (ARCM) is challenged with primary mission objectives of demonstrating deep space Extravehicular Activity (EVA) and tools, and obtaining asteroid samples to return to Earth for further study. Although the Modified Advanced Crew Escape Suit (MACES) is used for the EVAs, it has limited mobility which increases fatigue and decreases the crews' capability to perform EVA tasks. Furthermore, previous Shuttle and International Space Station (ISS) spacewalks have benefited from EVA interfaces which have been designed and manufactured on Earth. Rigid structurally mounted handrails, and tools with customized interfaces and restraints optimize EVA performance. For ARCM, some vehicle interfaces and tools can leverage heritage designs and experience. However, when the crew ventures onto an asteroid capture bag to explore the asteroid and collect rock samples, EVA complexity increases due to the uncertainty of the asteroid properties. The variability of rock size, shape and composition, as well as bunching of the fabric bag will complicate EVA translation, tool restraint and body stabilization. The unknown asteroid hardness and brittleness will complicate tool use. The rock surface will introduce added safety concerns for cut gloves and debris control. Feasible solutions to meet ARCM EVA objectives were identified using experience gained during Apollo, Shuttle, and ISS EVAs, terrestrial mountaineering practices, NASA Extreme Environment Mission Operations (NEEMO) 16 mission, and during Neutral Buoyancy Laboratory testing in the MACES suit. The proposed concept utilizes expandable booms and integrated features of the asteroid capture bag to position and restrain the crew at the asteroid worksite. These methods enable the capability to perform both finesse, and high load tasks necessary to collect samples for scientific characterization of the asteroid. This paper will explore the design trade space and options that were examined for EVA, the

  19. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF FLOOR DUST SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.19)

    EPA Science Inventory

    This SOP describes the method for collecting a floor dust sample from carpet. Dust samples will be collected in the room that the child uses most at home and/or at day care using a High Volume Small Surface Sampler (HVS3). In addition, participants will also be asked to donate a ...

  20. Sulfate and nitrate collected by filter sampling near the tropopause

    NASA Technical Reports Server (NTRS)

    Humenik, F. M.; Lezberg, E. A.; Otterson, D. A.

    1980-01-01

    Filter samples collected near the tropopause with an F-106 aircraft and two Boeing 747 aircraft were analyzed for sulfate and nitrate ion content. Within the range of routine commercial flight altitudes (at or below 12.5 km), stratospheric mass mixing ratios for the winter-spring group averaged 0.26 ppbm for sulfate and 0.35 ppbm for nitrate. For the summer-fall group, stratosphere mixing ratios averaged 0.13 ppbm and 0.25 ppbm for sulfate and nitrate, respectively. Winter-spring group tropospheric mass mixing ratios averaged 0.08 ppbm for sulfate and 0.10 ppbm for nitrate, while summer-fall group tropospheric mixing ratios averaged 0.05 ppbm for sulfate and 0.08 ppbm for nitrate. Correlations of the filter data with available ozone data suggest that the sulfate and nitrate are transported from the stratosphere to the troposphere.

  1. DS — Software for analyzing data collected using double sampling

    USGS Publications Warehouse

    Bart, Jonathan; Hartley, Dana

    2011-01-01

    DS analyzes count data to estimate density or relative density and population size when appropriate. The software is available at http://iwcbm.dev4.fsr.com/IWCBM/default.asp?PageID=126. The software was designed to analyze data collected using double sampling, but it also can be used to analyze index data. DS is not currently configured to apply distance methods or methods based on capture-recapture theory. Double sampling for the purpose of this report means surveying a sample of locations with a rapid method of unknown accuracy and surveying a subset of these locations using a more intensive method assumed to yield unbiased estimates. "Detection ratios" are calculated as the ratio of results from rapid surveys on intensive plots to the number actually present as determined from the intensive surveys. The detection ratios are used to adjust results from the rapid surveys. The formula for density is (results from rapid survey)/(estimated detection ratio from intensive surveys). Population sizes are estimated as (density)(area). Double sampling is well-established in the survey sampling literature—see Cochran (1977) for the basic theory, Smith (1995) for applications of double sampling in waterfowl surveys, Bart and Earnst (2002, 2005) for discussions of its use in wildlife studies, and Bart and others (in press) for a detailed account of how the method was used to survey shorebirds across the arctic region of North America. Indices are surveys that do not involve complete counts of well-defined plots or recording information to estimate detection rates (Thompson and others, 1998). In most cases, such data should not be used to estimate density or population size but, under some circumstances, may be used to compare two densities or estimate how density changes through time or across space (Williams and others, 2005). The Breeding Bird Survey (Sauer and others, 2008) provides a good example of an index survey. Surveyors record all birds detected but do not record

  2. Water column and bed-sediment core samples collected from Brownlee Reservoir near Oxbow, Oregon, 2012

    USGS Publications Warehouse

    Fosness, Ryan L.; Naymik, Jesse; Hopkins, Candice B.; DeWild, John F.

    2013-01-01

    The U.S. Geological Survey, in cooperation with Idaho Power Company, collected water-column and bed-sediment core samples from eight sites in Brownlee Reservoir near Oxbow, Oregon, during May 5–7, 2012. Water-column and bed-sediment core samples were collected at each of the eight sites and analyzed for total mercury and methylmercury. Additional bed-sediment core samples, collected from three of the eight sites, were analyzed for pesticides and other organic compounds, trace metals, and physical characteristics, such as particle size. Total mercury and methylmercury were detected in each of the water column and bed-sediment core samples. Only 17 of the 417 unique pesticide and organic compounds were detected in bed-sediment core samples. Concentrations of most organic wastewater compounds detected in bed sediment were less than the reporting level. Trace metals detected were greater than the reporting level in all the bed-sediment core samples submitted for analysis. The particle size distribution of bed-sediment core samples was predominantly clay mixed with silt.

  3. The Importance of Meteorite Collections to Sample Return Missions: Past, Present, and Future Considerations

    NASA Technical Reports Server (NTRS)

    Welzenbach, L. C.; McCoy, T. J.; Glavin, D. P.; Dworkin, J. P.; Abell, P. A.

    2012-01-01

    While much of the scientific community s current attention is drawn to sample return missions, it is the existing meteorite and cosmic dust collections that both provide the paradigms to be tested by these missions and the context for interpreting the results. Recent sample returns from the Stardust and Hayabusa missions provided us with new materials and insights about our Solar System history and processes. As an example, Stardust sampled CAIs among the population of cometary grains, requiring extensive and unexpected radial mixing in the early solar nebula. This finding would not have been possible, however, without extensive studies of meteoritic CAIs that established their high-temperature, inner Solar System formation. Samples returned by Stardust also revealed the first evidence of a cometary amino acid, a discovery that would not have been possible with current in situ flight instrument technology. The Hayabusa mission provided the final evidence linking ordinary chondrites and S asteroids, a hypothesis that developed from centuries of collection and laboratory and ground-based telescopic studies. In addition to these scientific findings, studies of existing meteorite collections have defined and refined the analytical techniques essential to studying returned samples. As an example, the fortuitous fall of the Allende CV3 and Murchison CM2 chondrites within months before the return of Apollo samples allowed testing of new state-of-the-art analytical facilities. The results of those studies not only prepared us to better study lunar materials, but unanticipated discoveries changed many of our concepts about the earliest history and processes of the solar nebula. This synergy between existing collections and future space exploration is certainly not limited to sample return missions. Laboratory studies confirmed the existence of meteorites from Mars and raised the provocative possibility of preservation of ancient microbial life. The laboratory studies in

  4. 49 CFR 199.111 - Retention of samples and additional testing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Retention of samples and additional testing. 199... SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.111 Retention of samples and additional testing. (a... period, the employee or the employee's representative, the operator, the Administrator, or, if...

  5. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF URINE SAMPLES (SOP-2.14)

    EPA Science Inventory

    This SOP describes the method for collecting urine samples from the study participants (children and their primary caregivers). Urine samples will be approximate 48-hr collections, collected as spot urine samples accumulated over the 48-hr sampling period. If the household or da...

  6. The Autism Simplex Collection: an international, expertly phenotyped autism sample for genetic and phenotypic analyses

    PubMed Central

    2014-01-01

    Background There is an urgent need for expanding and enhancing autism spectrum disorder (ASD) samples, in order to better understand causes of ASD. Methods In a unique public-private partnership, 13 sites with extensive experience in both the assessment and diagnosis of ASD embarked on an ambitious, 2-year program to collect samples for genetic and phenotypic research and begin analyses on these samples. The program was called The Autism Simplex Collection (TASC). TASC sample collection began in 2008 and was completed in 2010, and included nine sites from North America and four sites from Western Europe, as well as a centralized Data Coordinating Center. Results Over 1,700 trios are part of this collection, with DNA from transformed cells now available through the National Institute of Mental Health (NIMH). Autism Diagnostic Interview-Revised (ADI-R) and Autism Diagnostic Observation Schedule-Generic (ADOS-G) measures are available for all probands, as are standardized IQ measures, Vineland Adaptive Behavioral Scales (VABS), the Social Responsiveness Scale (SRS), Peabody Picture Vocabulary Test (PPVT), and physical measures (height, weight, and head circumference). At almost every site, additional phenotypic measures were collected, including the Broad Autism Phenotype Questionnaire (BAPQ) and Repetitive Behavior Scale-Revised (RBS-R), as well as the non-word repetition scale, Communication Checklist (Children’s or Adult), and Aberrant Behavior Checklist (ABC). Moreover, for nearly 1,000 trios, the Autism Genome Project Consortium (AGP) has carried out Illumina 1 M SNP genotyping and called copy number variation (CNV) in the samples, with data being made available through the National Institutes of Health (NIH). Whole exome sequencing (WES) has been carried out in over 500 probands, together with ancestry matched controls, and this data is also available through the NIH. Additional WES is being carried out by the Autism Sequencing Consortium (ASC), where the

  7. Atmospheric CO sub 2 concentrations derived from flask samples collected at USSR-operated sampling sites

    SciTech Connect

    Boden, T.A. . Carbon Dioxide Information Analysis Center); Brounshtein, A.M.; Faber, E.V.; Shashkov, A.A. )

    1991-12-01

    This document presents daily atmospheric CO{sub 2} concentrations from four USSR-operated sampling sites (Teriberka Station, Ocean Station Charlie, Bering Island, and Kotelny Island). The period of record varies by station with the earliest measurements dating back to 1983 and recent estimates from early 1991. These CO{sub 2} concentrations are derived from air samples collected in 1.5-L stainless steel electropolished flasks and later analyzed at the Main Geophysical Observatory (St. Petersburg, USSR) using a nondispersive infrared gas analyzer. Measurements not meeting wind direction, wind speed, inter-flask agreement, and climate condition criteria were either discarded or flagged. All measurements have been corrected for drift biases introduced during flask storage. These atmospheric CO{sub 2} concentrations are considered indicative of regional background air conditions and are directly traceable to the World Meteorological Organization's primary CO{sub 2} standards. These measurements support the rising trend in atmospheric CO{sub 2} concentrations measured at other monitoring sites around the world and may be compared with similar measurements made by various monitoring programs at other northern latitude sites. The document presents the atmospheric CO{sub 2} concentrations in graphical and tabular form, describes the sampling methods, defines limitations and restrictions of the data, and describes the information on the magnetic media.

  8. Evidence That Certain Waste Tank Headspace Vapor Samples Were Contaminated by Semivolatile Polymer Additives

    SciTech Connect

    Huckaby, James L.

    2006-02-09

    Vapor samples collected from the headspaces of the Hanford Site high-level radioactive waste tanks in 1994 and 1995 using the Vapor Sampling System (VSS) were reported to contain trace levels of phthalates, antioxidants, and certain other industrial chemicals that did not have a logical origin in the waste. This report examines the evidence these chemicals were sampling artifacts (contamination) and identifies the chemicals reported as headspace constituents that may instead have been contaminants. Specific recommendations are given regarding the marking of certain chemicals as suspect on the basis they were sampling manifold contaminants.

  9. Innovative on-site sample collection and analytical technologies

    SciTech Connect

    McLeod, M.D.; Yantz, C.S.; Marcelletti, N.

    1994-12-31

    Innovative advances in probe sampling and mobile laboratory technologies provide powerful tools which can substantially decrease the cost and shorten the duration of site investigation and remediation projects. Recent probe sampling technology advancements enable probes to obtain representative subsurface samples with the same quality of data as drilling techniques. Probe sampling equipment is specifically designed for environmental sampling and has several advantages over conventional methods for most sampling applications. Innovative mobile laboratory technology is currently available which enables mobile labs to rapidly deploy and generate cost effective regulatory compliant data on-site. The utilization of these technologies together provides a unique synergistic advantage for site assessment projects. It is now possible to fully characterize the extent of contamination of many sites in a single mobilization. Two case studies, a Superfund site and UST site, are included to demonstrate the use and advantages of these technologies.

  10. [From project-based sample collection to biobank].

    PubMed

    Baranyai, Zsolt; Mersich, Tamás; Dede, Kristóf; Besznyák, István; Zaránd, Attila; Teknos, Dániel; Nagy, Péter; Salamon, Ferenc; Nagy, Pál; Nagy, Zsolt; Kótai, Zsuzsanna; Szász, Marcell; Lukács, Lilla; Szállási, Zoltán; Jósa, Valéria; Jakab, Ferenc

    2011-04-10

    The research group takes samples for molecular genetical examinations from tumors removed during operations within ischemic time interval. Samples are stored in liquid nitrogen. Clinical data of these patients are recorded in an informatics system developed by the group. Patients are followed in an out-patient clinic set up for this purpose not financed by the National Health Insurance Fund. Tissue samples and follow up data are used to cooperate with molecular genetical laboratories.

  11. Additives

    NASA Technical Reports Server (NTRS)

    Smalheer, C. V.

    1973-01-01

    The chemistry of lubricant additives is discussed to show what the additives are chemically and what functions they perform in the lubrication of various kinds of equipment. Current theories regarding the mode of action of lubricant additives are presented. The additive groups discussed include the following: (1) detergents and dispersants, (2) corrosion inhibitors, (3) antioxidants, (4) viscosity index improvers, (5) pour point depressants, and (6) antifouling agents.

  12. 75 FR 35119 - 60-Day Notice of Proposed Information Collection: Form DS-4085 Application for Additional Visa...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-21

    ... Notice of Proposed Information Collection: Form DS-4085 Application for Additional Visa Pages or... the Paperwork Reduction Act of 1995. Title of Information Collection: Application for Additional Visa... collection: The information collected on the DS-4085 is used to facilitate the issuance of additional...

  13. 49 CFR 199.111 - Retention of samples and additional testing.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.111 Retention of samples and additional testing. (a) Samples that yield positive results on confirmation must be retained by the laboratory in properly...

  14. 40 CFR 80.8 - Sampling methods for gasoline, diesel fuel, fuel additives, and renewable fuels.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of the Federal Register under 5 U.S.C. 552(a) and 1 CFR part 51. To enforce any edition other than... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Sampling methods for gasoline, diesel... Provisions § 80.8 Sampling methods for gasoline, diesel fuel, fuel additives, and renewable fuels....

  15. MRT letter: Micro- to nanoscale sample collection for high throughput microscopy.

    PubMed

    Cheong, Brandon Huey-Ping; Liew, Oi Wah; Ng, Tuck Wah

    2013-08-01

    In high throughput microscopy, it is often assumed that the objects under investigation are fixed spatially. In addition, it is also presumed that the objects are sufficiently populated, otherwise there will be need to search through vast tracks of field of views before any recording can be done. The ability to collect objects at one location in the hydrated state is thus desirable and this is a challenge when the density of target objects in a sample is very low. In this work, we report that the generation of a squeezing flow from a circular coverslip compressing on suspensions is able to collect particulate (microbeads, fluorescent nanobeads and live algal cells) and non-particulate (EGFP) objects at the rim region of the coverslip. With a coverslip of 13 mm diameter, volumes between 2 µL and 4 µL were found to completely fill the coverslip without breaching the rims. Sample compression speeds between 100 µm/s and 1000 µm/s did not have any effect on object collection outcomes. In effect, the simple placement of coverslips on top the drop of sample by hand without a motorized translator was found to produce similar collection outcomes. Quantitative measurements confirmed that all the objects investigated were displaced and relocated at the rim regions to a very high degree. PMID:23733610

  16. DEVELOPMENT OF A TAMPER RESISTANT/INDICATING AEROSOL COLLECTION SYSTEM FOR ENVIRONMENTAL SAMPLING AT BULK HANDLING FACILITIES

    SciTech Connect

    Sexton, L.

    2012-06-06

    Environmental sampling has become a key component of International Atomic Energy Agency (IAEA) safeguards approaches since its approval for use in 1996. Environmental sampling supports the IAEA's mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a Nation State. Swipe sampling is the most commonly used method for the collection of environmental samples from bulk handling facilities. However, augmenting swipe samples with an air monitoring system, which could continuously draw samples from the environment of bulk handling facilities, could improve the possibility of the detection of undeclared activities. Continuous sampling offers the opportunity to collect airborne materials before they settle onto surfaces which can be decontaminated, taken into existing duct work, filtered by plant ventilation, or escape via alternate pathways (i.e. drains, doors). Researchers at the Savannah River National Laboratory and Oak Ridge National Laboratory have been working to further develop an aerosol collection technology that could be installed at IAEA safeguarded bulk handling facilities. The addition of this technology may reduce the number of IAEA inspector visits required to effectively collect samples. The principal sample collection device is a patented Aerosol Contaminant Extractor (ACE) which utilizes electrostatic precipitation principles to deposit particulates onto selected substrates. Recent work has focused on comparing traditional swipe sampling to samples collected via an ACE system, and incorporating tamper resistant and tamper indicating (TRI) technologies into the ACE system. Development of a TRI-ACE system would allow collection of samples at uranium/plutonium bulk handling facilities in a manner that ensures sample integrity and could be an important addition to the international nuclear safeguards inspector's toolkit. This work was supported by the Next Generation Safeguards Initiative (NGSI), Office

  17. 40 CFR 761.310 - Collecting the sample.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PROHIBITIONS Sampling Non-Porous Surfaces for Measurement-Based Use, Reuse, and On-Site or Off-Site Disposal... a nearly flat, non-porous surface. For small surfaces, use the same procedure as for the...

  18. 40 CFR 761.310 - Collecting the sample.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROHIBITIONS Sampling Non-Porous Surfaces for Measurement-Based Use, Reuse, and On-Site or Off-Site Disposal... a nearly flat, non-porous surface. For small surfaces, use the same procedure as for the...

  19. 40 CFR 761.310 - Collecting the sample.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROHIBITIONS Sampling Non-Porous Surfaces for Measurement-Based Use, Reuse, and On-Site or Off-Site Disposal... a nearly flat, non-porous surface. For small surfaces, use the same procedure as for the...

  20. Apollo Lunar Sample Photographs: Digitizing the Moon Rock Collection

    NASA Technical Reports Server (NTRS)

    Lofgren, Gary E.; Todd, Nancy S.; Runco, S. K.; Stefanov, W. L.

    2011-01-01

    The Acquisition and Curation Office at JSC has undertaken a 4-year data restoration project effort for the lunar science community funded by the LASER program (Lunar Advanced Science and Exploration Research) to digitize photographs of the Apollo lunar rock samples and create high resolution digital images. These sample photographs are not easily accessible outside of JSC, and currently exist only on degradable film in the Curation Data Storage Facility

  1. Clinical pathology and sample collection of exotic small mammals.

    PubMed

    Ness, R D

    1999-09-01

    The clinical pathology of some of the less common and newly emerging small mammal species is detailed in this article. The species covered here include the chinchilla, prairie dog, African hedgehog, and sugar glider. Venipuncture sites and sampling techniques are discussed in general and for each species. Detailed information on the hematology and serum biochemistry values of these animals is presented in numerous tables. Specific information is also provided for urinalysis, fecal analysis, dermatologic sampling, and cytology. PMID:11229045

  2. Analysis of zinc in biological samples by flame atomic absorption spectrometry: use of addition calibration technique.

    PubMed

    Dutra, Rosilene L; Cantos, Geny A; Carasek, Eduardo

    2006-01-01

    The quantification of target analytes in complex matrices requires special calibration approaches to compensate for additional capacity or activity in the matrix samples. The standard addition is one of the most important calibration procedures for quantification of analytes in such matrices. However, this technique requires a great number of reagents and material, and it consumes a considerable amount of time throughout the analysis. In this work, a new calibration procedure to analyze biological samples is proposed. The proposed calibration, called the addition calibration technique, was used for the determination of zinc (Zn) in blood serum and erythrocyte samples. The results obtained were compared with those obtained using conventional calibration techniques (standard addition and standard calibration). The proposed addition calibration was validated by recovery tests using blood samples spiked with Zn. The range of recovery for blood serum and erythrocyte samples were 90-132% and 76-112%, respectively. Statistical studies among results obtained by the addition technique and conventional techniques, using a paired two-tailed Student's t-test and linear regression, demonstrated good agreement among them. PMID:16943611

  3. Curating NASA's Past, Present, and Future Extraterrestrial Sample Collections

    NASA Technical Reports Server (NTRS)

    McCubbin, F. M.; Allton, J. H.; Evans, C. A.; Fries, M. D.; Nakamura-Messenger, K.; Righter, K.; Zeigler, R. A.; Zolensky, M.; Stansbery, E. K.

    2016-01-01

    The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10E "Curation of Extraterrestrial Materials", JSC is charged with "...curation of all extra-terrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "...documentation, preservation, preparation, and distribution of samples for research, education, and public outreach." Here we describe some of the past, present, and future activities of the NASA Curation Office.

  4. 40 CFR 761.310 - Collecting the sample.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) area to represent surface area PCB concentrations of each square meter or fraction of a square meter of a nearly flat, non-porous surface. For small surfaces, use the same procedure as for the standard... PROHIBITIONS Sampling Non-Porous Surfaces for Measurement-Based Use, Reuse, and On-Site or Off-Site...

  5. 40 CFR 761.310 - Collecting the sample.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) area to represent surface area PCB concentrations of each square meter or fraction of a square meter of a nearly flat, non-porous surface. For small surfaces, use the same procedure as for the standard... PROHIBITIONS Sampling Non-Porous Surfaces for Measurement-Based Use, Reuse, and On-Site or Off-Site...

  6. Methodological Issues of Sample Collection and Analysis of Exhaled Breath

    EPA Science Inventory

    Recommended standardized procedures have been developed for measurement of exhaled lower respiratory nitric oxide (NO) and nasal NO. It would be desirable to develop similar guidelines for the sampling of exhaled breath related to other compounds. For such systemic volatile o...

  7. Spectroscopic Characterization of Dust-Fall Samples Collected from Greater Cairo, Egypt.

    PubMed

    Shaltout, Abdallah A; Allam, Mousa A; Mostafa, Nasser Y; Heiba, Zein K

    2016-04-01

    This work aimed to characterize dust-fall samples collected from street's trees in Greater Cairo (GC), Egypt, and its surroundings by different spectroscopic techniques, namely; X-ray diffraction (XRD), attenuated total-reflection Fourier transform infrared (ATR-FTIR), particle-size analyzer, and scanning electron microscopy (SEM) combined with energy dispersive X-ray measurements. Samples were collected from 19 different locations inside and outside of GC. Quantitative phase analysis of the dust-fall samples was performed using the Rietveld method. Results showed that the most frequently observed phases in the dust-fall samples were calcite (CaCO3), dolomite (CaMg(CO3)2), gypsum (CaSO4·2H2O), and quartz (SiO2) with average concentrations of 39 ± 16, 8 ± 7, 22 ± 13, and 33 ± 14 wt%, respectively. The occurrence of these constituents referred to a combination of different anthropogenic and natural sources. The ATR-FTIR results are in good agreements with XRD data of the different observed phases. Based on the SEM and particle-size measurements, quantitative determination of the particle-size distribution was described. It was found that not only the large-sized particles are deposited but also the small-sized ones (PM10 and PM2.5). In addition, the particle size of the collected dust-fall samples varied from 0.1 to 200 µm with an average particle size of 17.36 µm; however, the particle size ranged from 2.5 to 40 µm predominated in all of the dust-fall samples. PMID:26710766

  8. 40 CFR 761.283 - Determination of the number of samples to collect and sample collection locations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the extent sufficient to result in a two-dimensional grid completely overlaying the sampling area. (3... type of bulk PCB remediation waste or porous surface at the cleanup site, there are two options....

  9. 40 CFR 761.283 - Determination of the number of samples to collect and sample collection locations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the extent sufficient to result in a two-dimensional grid completely overlaying the sampling area. (3... type of bulk PCB remediation waste or porous surface at the cleanup site, there are two options....

  10. 40 CFR 761.283 - Determination of the number of samples to collect and sample collection locations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the extent sufficient to result in a two-dimensional grid completely overlaying the sampling area. (3... type of bulk PCB remediation waste or porous surface at the cleanup site, there are two options....

  11. 40 CFR 761.283 - Determination of the number of samples to collect and sample collection locations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the extent sufficient to result in a two-dimensional grid completely overlaying the sampling area. (3... type of bulk PCB remediation waste or porous surface at the cleanup site, there are two options....

  12. 40 CFR 761.283 - Determination of the number of samples to collect and sample collection locations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the extent sufficient to result in a two-dimensional grid completely overlaying the sampling area. (3... type of bulk PCB remediation waste or porous surface at the cleanup site, there are two options....

  13. Characterization Data Package for Containerized Sludge Samples Collected from Engineered Container SCS-CON-210

    SciTech Connect

    Fountain, Matthew S.; Fiskum, Sandra K.; Baldwin, David L.; Daniel, Richard C.; Bos, Stanley J.; Burns, Carolyn A.; Carlson, Clark D.; Coffey, Deborah S.; Delegard, Calvin H.; Edwards, Matthew K.; Greenwood, Lawrence R.; Neiner, Doinita; Oliver, Brian M.; Pool, Karl N.; Schmidt, Andrew J.; Shimskey, Rick W.; Sinkov, Sergey I.; Snow, Lanee A.; Soderquist, Chuck Z.; Thompson, Christopher J.; Trang-Le, Truc LT; Urie, Michael W.

    2013-09-10

    This data package contains the K Basin sludge characterization results obtained by Pacific Northwest National Laboratory during processing and analysis of four sludge core samples collected from Engineered Container SCS-CON-210 in 2010 as requested by CH2M Hill Plateau Remediation Company. Sample processing requirements, analytes of interest, detection limits, and quality control sample requirements are defined in the KBC-33786, Rev. 2. The core processing scope included reconstitution of a sludge core sample distributed among four to six 4-L polypropylene bottles into a single container. The reconstituted core sample was then mixed and subsampled to support a variety of characterization activities. Additional core sludge subsamples were combined to prepare a container composite. The container composite was fractionated by wet sieving through a 2,000 micron mesh and a 500-micron mesh sieve. Each sieve fraction was sampled to support a suite of analyses. The core composite analysis scope included density determination, radioisotope analysis, and metals analysis, including the Waste Isolation Pilot Plant Hazardous Waste Facility Permit metals (with the exception of mercury). The container composite analysis included most of the core composite analysis scope plus particle size distribution, particle density, rheology, and crystalline phase identification. A summary of the received samples, core sample reconstitution and subsampling activities, container composite preparation and subsampling activities, physical properties, and analytical results are presented. Supporting data and documentation are provided in the appendices. There were no cases of sample or data loss and all of the available samples and data are reported as required by the Quality Assurance Project Plan/Sampling and Analysis Plan.

  14. Inherent variability in lead and copper collected during standardized sampling.

    PubMed

    Masters, Sheldon; Parks, Jeffrey; Atassi, Amrou; Edwards, Marc A

    2016-03-01

    Variability in the concentration of lead and copper sampled at consumers' taps poses challenges to assessing consumer health threats and the effectiveness of corrosion control. To examine the minimum variability that is practically achievable, standardized rigs with three lead and copper containing plumbing materials (leaded brass, copper tube with lead solder, and a lead copper connection) were deployed at five utilities and sampled with regimented protocols. Variability represented by relative standard deviation (RSD) in lead release was high in all cases. The brass had the lowest variability in lead release (RSD = 31 %) followed by copper-solder (RSD = 49%) and lead-copper (RSD = 80%). This high inherent variability is due to semi-random detachment of particulate lead to water, and represents a modern reality of water lead problems that should be explicitly acknowledged and considered in all aspects of exposure, public education, and monitoring. PMID:26896965

  15. Inherent variability in lead and copper collected during standardized sampling.

    PubMed

    Masters, Sheldon; Parks, Jeffrey; Atassi, Amrou; Edwards, Marc A

    2016-03-01

    Variability in the concentration of lead and copper sampled at consumers' taps poses challenges to assessing consumer health threats and the effectiveness of corrosion control. To examine the minimum variability that is practically achievable, standardized rigs with three lead and copper containing plumbing materials (leaded brass, copper tube with lead solder, and a lead copper connection) were deployed at five utilities and sampled with regimented protocols. Variability represented by relative standard deviation (RSD) in lead release was high in all cases. The brass had the lowest variability in lead release (RSD = 31 %) followed by copper-solder (RSD = 49%) and lead-copper (RSD = 80%). This high inherent variability is due to semi-random detachment of particulate lead to water, and represents a modern reality of water lead problems that should be explicitly acknowledged and considered in all aspects of exposure, public education, and monitoring.

  16. Extravehicular Activity Asteroid Exploration and Sample Collection Capability

    NASA Technical Reports Server (NTRS)

    Sipila, Stephanie A.; Scoville, Zebulon C.; Bowie, Jonathan T.; Buffington, Jesse A.

    2014-01-01

    One of the challenging primary objectives associated with NASA's Asteroid Redirect Crewed Mission (ARCM) is to demonstrate deep space Extravehicular Activity (EVA) and tools and to obtain asteroid samples to return to Earth for further study. Prior Shuttle and International Space Station (ISS) spacewalks have benefited from engineered EVA interfaces which have been designed and manufactured on Earth. Rigid structurally mounted handrails, and tools with customized interfaces and restraints optimize EVA performance. For ARCM, EVA complexity increases due to the uncertainty of the asteroid properties. The variability of rock size, shape and composition, as well as behavior of the asteroid capture mechanism will complicate EVA translation, tool restraint, and body stabilization. The unknown asteroid hardness and brittleness will complicate tool use. The rock surface will introduce added safety concerns for cut gloves and debris control. Feasible solutions to meet ARCM EVA objectives were identified using experience gained during Apollo, Shuttle, and ISS EVAs, terrestrial mountaineering practices, NASA Extreme Environment Mission Operations (NEEMO) 16 mission, and during Neutral Buoyancy Laboratory testing in the Modified Advanced Crew Escape Suit (MACES) suit. This paper will summarize the overall operational concepts for conducting EVAs for the ARCM mission including translation paths and body restraint methods, potential tools used to extract the samples, design implications for the Asteroid Redirect Vehicle (ARV) for EVA, and the results of early development testing of potential EVA tasks.

  17. Self-Collected versus Clinician-Collected Sampling for Chlamydia and Gonorrhea Screening: A Systemic Review and Meta-Analysis

    PubMed Central

    Lunny, Carole; Taylor, Darlene; Hoang, Linda; Wong, Tom; Gilbert, Mark; Lester, Richard; Krajden, Mel; Ogilvie, Gina

    2015-01-01

    Background The increases in STI rates since the late 1990s in Canada have occurred despite widespread primary care and targeted public health programs and in the setting of universal health care. More innovative interventions are required that would eliminate barriers to STI testing such as internet-based or mail-in home and community service testing for patients that are hard to reach, who refuse to go for clinician-based testing, or who decline an examination. Jurisdictions such as New Zealand and some American states currently use self-collected sampling, but without the required evidence to determine whether self-collected specimens are as accurate as clinician-collected specimens in terms of chlamydia and gonorrhea diagnostic accuracy. The objective of the review is to compare self-collected vaginal, urine, pharyngeal and rectal samples to our reference standard - clinician-collected cervical, urethral, pharyngeal and rectal sampling techniques to identify a positive specimen using nucleic acid amplification test assays. Methods The hierarchical summary receiver operating characteristic and the fixed effect models were used to assess the accuracy of comparable specimens that were collected by patients compared to clinicians. Sensitivity and specificity estimates with 95% confidence intervals (CI) were reported as our main outcome measures. Findings We included 21 studies based on over 6100 paired samples. Fourteen included studies examined chlamydia only, 6 compared both gonorrhea and chlamydia separately in the same study, and one examined gonorrhea. The six chlamydia studies comparing self-collection by vaginal swab to a clinician-collected cervical swab had the highest sensitivity (92%, 95% CI 87-95) and specificity (98%, 95% CI 97-99), compared to other specimen-types (urine/urethra or urine/cervix). Six studies compared urine self-samples to urethra clinician-collected samples in males and produced a sensitivity of 88% (95% CI 83-93) and a specificity of

  18. Additive quantification on polymer thin films by ToF-SIMS: aging sample effects

    NASA Astrophysics Data System (ADS)

    Poleunis, Claude; Médard, Nicolas; Bertrand, Patrick

    2004-06-01

    Thin films (150 nm) of an amorphous polyester (polyethylene(terephthalate-isophthalate)) containing variable concentrations of an antioxidant (Irgafos™ 168) and a UV-stabilizer (Hostavin™ N30) have been prepared by spin-coating. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) results showed, in the case of a single additive system (antioxidant), that the additive intensity increased on the polymer surface during the first five aging days (exudation phenomenon), followed by an intensity decrease, which was related to the adsorption of hydrocarbon contaminations on the sample surface. This kinetic competition was observed whatever the used additive concentration. In the case of the binary additive system (antioxidant and UV-stabilizer), the antioxidant behavior was similar to the single additive system, whereas, the UV-stabilizer evolution corresponded to an additive depletion, followed by an exudation. These results indicate that it is necessary to be very careful when comparing ToF-SIMS data for additive quantification on polymer surfaces. It is strongly recommended to compare samples having the same aging time, because the surface composition was seen to be strongly dependent of the aging time.

  19. 31. VIEW FROM SOUTHWEST TO CORNER WHERE SAMPLING/CRUSHING ADDITIONS ABUT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. VIEW FROM SOUTHWEST TO CORNER WHERE SAMPLING/CRUSHING ADDITIONS ABUT CRUSHED OXIDIZED ORE BIN. INTACT BARREN SOLUTION TANK VISIBLE IN FRONT OF CRUSHED ORE BIN. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD

  20. Studies of levels of biogenic amines in meat samples in relation to the content of additives.

    PubMed

    Jastrzębska, Aneta; Kowalska, Sylwia; Szłyk, Edward

    2016-01-01

    The impact of meat additives on the concentration of biogenic amines and the quality of meat was studied. Fresh white and red meat samples were fortified with the following food additives: citric and lactic acids, disodium diphosphate, sodium nitrite, sodium metabisulphite, potassium sorbate, sodium chloride, ascorbic acid, α-tocopherol, propyl 3,4,5-trihydroxybenzoate (propyl gallate) and butylated hydroxyanisole. The content of spermine, spermidine, putrescine, cadaverine, histamine, tyramine, tryptamine and 2-phenylethylamine was determined by capillary isotachophoretic methods in meat samples (fresh and fortified) during four days of storage at 4°C. The results were applied to estimate the impact of the tested additives on the formation of biogenic amines in white and red meat. For all tested meats, sodium nitrite, sodium chloride and disodium diphosphate showed the best inhibition. However, cadaverine and putrescine were characterised by the biggest changes in concentration during the storage time of all the additives. Based on the presented data for the content of biogenic amines in meat samples analysed as a function of storage time and additives, we suggest that cadaverine and putrescine have a significant impact on meat quality. PMID:26515667

  1. Studies of levels of biogenic amines in meat samples in relation to the content of additives.

    PubMed

    Jastrzębska, Aneta; Kowalska, Sylwia; Szłyk, Edward

    2016-01-01

    The impact of meat additives on the concentration of biogenic amines and the quality of meat was studied. Fresh white and red meat samples were fortified with the following food additives: citric and lactic acids, disodium diphosphate, sodium nitrite, sodium metabisulphite, potassium sorbate, sodium chloride, ascorbic acid, α-tocopherol, propyl 3,4,5-trihydroxybenzoate (propyl gallate) and butylated hydroxyanisole. The content of spermine, spermidine, putrescine, cadaverine, histamine, tyramine, tryptamine and 2-phenylethylamine was determined by capillary isotachophoretic methods in meat samples (fresh and fortified) during four days of storage at 4°C. The results were applied to estimate the impact of the tested additives on the formation of biogenic amines in white and red meat. For all tested meats, sodium nitrite, sodium chloride and disodium diphosphate showed the best inhibition. However, cadaverine and putrescine were characterised by the biggest changes in concentration during the storage time of all the additives. Based on the presented data for the content of biogenic amines in meat samples analysed as a function of storage time and additives, we suggest that cadaverine and putrescine have a significant impact on meat quality.

  2. Collection and analysis of NASA clean room air samples

    NASA Technical Reports Server (NTRS)

    Sheldon, L. S.; Keever, J.

    1985-01-01

    The environment of the HALOE assembly clean room at NASA Langley Research Center is analyzed to determine the background levels of airborne organic compounds. Sampling is accomplished by pumping the clean room air through absorbing cartridges. For volatile organics, cartridges are thermally desorbed and then analyzed by gas chromatography and mass spectrometry, compounds are identified by searching the EPA/NIH data base using an interactive operator INCOS computer search algorithm. For semivolatile organics, cartridges are solvent entracted and concentrated extracts are analyzed by gas chromatography-electron capture detection, compound identification is made by matching gas chromatogram retention times with known standards. The detection limits for the semivolatile organics are; 0.89 ng cu m for dioctylphlhalate (DOP) and 1.6 ng cu m for polychlorinated biphenyls (PCB). The detection limit for volatile organics ranges from 1 to 50 parts per trillion. Only trace quantities of organics are detected, the DOP levels do not exceed 2.5 ng cu m and the PCB levels do not exceed 454 ng cu m.

  3. Study design in qualitative research--2: Sampling and data collection strategies.

    PubMed

    Devers, K J; Frankel, R M

    2000-01-01

    In two prior papers in our series on qualitative research [Frankel & Devers (2000a, 2000b) Qualitative research: a consumer's guide, Education for Health, 13, 113-123; Frankel & Devers (2000) Study design in qualitative research-1: developing research questions and assessing research needs, Education for Health, 13, 251-261], we examine two critical issues in qualitative research design: sampling, including identifying and negotiating access to research sites and subjects, and data collection and management. We describe these two key steps in the qualitative research design process, discuss challenges that often emerge when pursuing these steps, and provide guidelines for addressing them. Qualitative research most often uses "purposive," rather than random, sampling strategies. A good understanding of these sampling strategies and why they are used is central to designing a credible qualitative study. In addition, given the real-world context in which most qualitative research is carried out, identifying and negotiating access to research sites and subjects are critical parts of the process. We also provide suggestions for developing and maintaining productive and mutually satisfying research relationships with sites and subjects. Finally, data collection and management are often neglected subjects in qualitative research. We offer practical advice on how to collect and manage qualitative data, including factors to consider when deciding how structured the data collection process should be, the pros and cons of audio- and/or videotaping compared with note-taking, and tips for writing up field notes and document management. A forthcoming, final paper in the series will focus on qualitative data analysis and the publication of qualitative research results. PMID:14742088

  4. RoboHound:developing sample collection and preconcentration hardware for a remote trace explosives detection system.

    SciTech Connect

    Peterson, David J.; Denning, David J.; Hobart, Clinton G.; Lenz, Michael C.; Anderson, Robert J.; Carlson, Dennis L.; Hunter, John Anthony; Gladwell, T. Scott; Mitchell, Mary-Anne; Hannum, David W.; Baumann, Mark J.

    2005-09-01

    The RoboHound{trademark} Project was a three-year, multiphase project at Sandia National Laboratories to build and refine a working prototype trace explosive detection system as a tool for a commercial robot. The RoboHound system was envisioned to be a tool for emergency responders to test suspicious items (i.e., packages or vehicles) for explosives while maintaining a safe distance. The project investigated combining Sandia's expertise in trace explosives detection with a wheeled robotic platform that could be programmed to interrogate suspicious items remotely for the presence of explosives. All of the RoboHound field tests were successful, especially with regards to the ability to collect and detect trace samples of RDX. The project has gone from remote sampling with human intervention to a fully automatic system that requires no human intervention until the robot returns from a sortie. A proposal is being made for additional work leading towards commercialization.

  5. The use of fecal markers to facilitate sample collection in group-housed cats.

    PubMed

    Griffin, Brenda

    2002-03-01

    The provision of proper social housing is a priority when designing an experiment using domestic cats as laboratory animals. When animals are group-housed, studies requiring analysis of stool samples from individual subjects pose difficulty in sample collection and identification. In this study, commercially available concentrated food colorings (known as bakers pastes) were used as fecal markers in group-housed cats. Cats readily consumed 0.5 ml of bakers paste food coloring once daily in canned cat food. Colorings served as fecal markers by imparting a distinct color to each cat s feces, allowing identification in the litter box. In addition, colored glitter (1/8 teaspoon in canned food) was fed to cats and found to be a reliable fecal marker. Long-term feeding of colorings and glitter was found to be safe and effective at yielding readily identifiable stools. PMID:11958604

  6. 40 CFR 761.286 - Sample size and procedure for collecting a sample.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) TOXIC SUBSTANCES CONTROL ACT POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS Sampling To Verify Completion of Self-Implementing Cleanup...

  7. 7 CFR 52.45 - Inspection fees when charges for sampling have not been collected.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... PROCESSED FRUITS AND VEGETABLES, PROCESSED PRODUCTS THEREOF, AND CERTAIN OTHER PROCESSED FOOD PRODUCTS 1... sampling have not been collected. For any lot of processed products from which a sample is drawn by...

  8. 7 CFR 52.45 - Inspection fees when charges for sampling have not been collected.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... PROCESSED FRUITS AND VEGETABLES, PROCESSED PRODUCTS THEREOF, AND CERTAIN OTHER PROCESSED FOOD PRODUCTS 1... sampling have not been collected. For any lot of processed products from which a sample is drawn by...

  9. Odour and flavour thresholds of gasoline additives (MTBE, ETBE and TAME) and their occurrence in Dutch drinking water collection areas.

    PubMed

    van Wezel, Annemarie; Puijker, Leo; Vink, Cees; Versteegh, Ans; de Voogt, Pim

    2009-07-01

    The use of ETBE (ethyl-tert-butylether) as gasoline additive has recently grown rapidly. Contamination of aquatic systems is well documented for MTBE (methyl-tert-butylether), but less for other gasoline additives. Due to their mobility they may easily reach drinking water collection areas. Odour and flavour thresholds of MTBE are known to be low, but for ETBE and TAME (methyl-tert-amylether) hardly information is available. The objective here is to determine these thresholds for MTBE, ETBE and TAME, and relate these to concentrations monitored in thousands of samples from Dutch drinking water collection areas. For ETBE odour and flavour thresholds are low with 1-2microgL(-1), for MTBE and TAME they range from 7 to 16microg L(-1). In most groundwater collection areas MTBE concentrations are below 0.1microg L(-1). In phreatic groundwaters in sandy soils not covered by a protective soil layer, occasionally MTBE occurs at higher concentrations. For surface water collection areas a minority of the locations is free of MTBE. For river bank and dune infiltrates, at a few locations the odour and flavour threshold is exceeded. For ETBE fewer monitoring data are available. ETBE was found in 2 out of 37 groundwater collection areas, in concentrations below 1microgL(-1). In the surface water collection areas monitored ETBE was found in concentrations near to the odour and flavour thresholds. The low odour and flavour thresholds combined with the high mobility and persistence of these compounds, their high production volumes and their increased use may yield problems with future production of drinking water.

  10. Sample preparation, data collection and preliminary data analysis in biomolecular solution X-ray scattering

    PubMed Central

    Grishaev, Alexander

    2012-01-01

    In addition to the classic methods of structural biology - X-ray crystallography and NMR, solution X-ray scattering (SAXS) is starting to play an important role in experiential structural investigation of biological macromolecules. Ease of SAXS data collection and sophistication of its data analysis tools increasingly used as black boxes can be seen as both a blessing and a curse. On one hand, a sample set aside for solution scattering will always yield experimental data, including cases when macromolecule cannot be crystallized or when it is too large for application of solution NMR. On the other hand, any sample, whether pure or contaminated, whether mono- or polydisperse, will yield scattering data and it is up to the user to ensure the absence of artifacts in them and to choose a proper structural modeling strategy. We will discuss experimental aspects of X-ray solution scattering including sample preparation, data collection, as well as the steps in data processing and preliminary analysis that need to be carried out to ensure the absence of artifacts. Our goal is to summarize everything than can possibly go wrong with SAXS data measurement so that the user can have confidence in the data before they enter structural modeling. PMID:23151743

  11. Effects of atmospheric precipitation additions on phytoplankton photosynthesis in Lake Michigan water samples

    SciTech Connect

    Parker, J.I.; Tisue, G.T.; Kennedy, C.W.; Seils, C.A.

    1981-01-01

    The effects of incremental additions (0.1 to 50% v/v) of atmospheric precipitation on phytoplankton photosynthesis (/sup 14/C uptake) were tested in Lake Michigan water samples. Wet deposition was used in experiments I, III, and IV, and a melted snow core was used in experiment II. Additions of precipitation significantly reduced photosynthesis in the first three experiments, starting at about the 5 to 15% treatment level. No significant difference occurred in experiment IV, but photosynthesis was greater than in the control samples and this precipitation sample appeared to stimulate primary productivity. Soluble reactive phosphate, nitrate, and ammonia levels in the precipitation samples exceeded the lake water averages by factors of 10, 2, and 50, respectively. Silicon levels in precipitation reduced pH very little and no consistent relationship was observed with reduced photosynthesis. Alkalinity was greatly reduced in the treated samples and special precautions were required in ce, Ti, Be, Co, Cu, Mo, Ni, P,f the Pd crystals of about 30 A. Possible mechanisms are discussed for isotope exchange in CO molecules in these catalysts and for the promoting effect of Pd on the activity of CuO.

  12. Additive non-uniform random sampling in superimposed fiber Bragg grating strain gauge

    NASA Astrophysics Data System (ADS)

    Ma, Y. C.; Liu, H. Y.; Yan, S. B.; Yang, Y. H.; Yang, M. W.; Li, J. M.; Tang, J.

    2013-05-01

    This paper demonstrates an additive non-uniform random sampling and interrogation method for dynamic and/or static strain gauge using a reflection spectrum from two superimposed fiber Bragg gratings (FBGs). The superimposed FBGs are designed to generate non-equidistant space of a sensing pulse train in the time domain during dynamic strain gauge. By combining centroid finding with smooth filtering methods, both the interrogation speed and accuracy are improved. A 1.9 kHz dynamic strain is measured by generating an additive non-uniform randomly distributed 2 kHz optical sensing pulse train from a mean 500 Hz triangular periodically changing scanning frequency.

  13. Collecting cometary soil samples? Development of the ROSETTA sample acquisition system

    NASA Technical Reports Server (NTRS)

    Coste, P. A.; Fenzi, M.; Eiden, Michael

    1993-01-01

    In the reference scenario of the ROSETTA CNRS mission, the Sample Acquisition System is mounted on the Comet Lander. Its tasks are to acquire three kinds of cometary samples and to transfer them to the Earth Return Capsule. Operations are to be performed in vacuum and microgravity, on a probably rough and dusty surface, in a largely unknown material, at temperatures in the order of 100 K. The concept and operation of the Sample Acquisition System are presented. The design of the prototype corer and surface sampling tool, and of the equipment for testing them at cryogenic temperatures in ambient conditions and in vacuum in various materials representing cometary soil, are described. Results of recent preliminary tests performed in low temperature thermal vacuum in a cometary analog ice-dust mixture are provided.

  14. 40 CFR 761.286 - Sample size and procedure for collecting a sample.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) TOXIC SUBSTANCES CONTROL ACT POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING... On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6... PCB remediation waste or porous surfaces, collect at least 20 milliliters of waste, or a portion...

  15. 40 CFR 761.286 - Sample size and procedure for collecting a sample.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) TOXIC SUBSTANCES CONTROL ACT POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING... On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6... PCB remediation waste or porous surfaces, collect at least 20 milliliters of waste, or a portion...

  16. 40 CFR 761.286 - Sample size and procedure for collecting a sample.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) TOXIC SUBSTANCES CONTROL ACT POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING... On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6... PCB remediation waste or porous surfaces, collect at least 20 milliliters of waste, or a portion...

  17. 40 CFR 761.286 - Sample size and procedure for collecting a sample.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) TOXIC SUBSTANCES CONTROL ACT POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING... On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6... PCB remediation waste or porous surfaces, collect at least 20 milliliters of waste, or a portion...

  18. 75 FR 80072 - Proposed Extension of Existing Information Collection; Radiation Sampling and Exposure Records

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-21

    ... Safety and Health Administration Proposed Extension of Existing Information Collection; Radiation... extension of the information collection for Radiation Sampling and Exposure Records, 30 CFR 57.5037 and 57... for radiation sampling and exposure records. MSHA does not intend to publish the results from...

  19. The use of Vacutainer tubes for collection of soil samples for helium analysis

    USGS Publications Warehouse

    Hinkle, Margaret E.; Kilburn, James E.

    1979-01-01

    Measurements of the helium concentration of soil samples collected and stored in Vacutainer-brand evacuated glass tubes show that Vacutainers are reliable containers for soil collection. Within the limits of reproducibility, helium content of soils appears to be independent of variations in soil temperature, barometric pressure, and quantity of soil moisture present in the sample.

  20. Sample data processing in an additive and reproducible taxonomic workflow by using character data persistently linked to preserved individual specimens

    PubMed Central

    Kilian, Norbert; Henning, Tilo; Plitzner, Patrick; Müller, Andreas; Güntsch, Anton; Stöver, Ben C.; Müller, Kai F.; Berendsohn, Walter G.; Borsch, Thomas

    2015-01-01

    We present the model and implementation of a workflow that blazes a trail in systematic biology for the re-usability of character data (data on any kind of characters of pheno- and genotypes of organisms) and their additivity from specimen to taxon level. We take into account that any taxon characterization is based on a limited set of sampled individuals and characters, and that consequently any new individual and any new character may affect the recognition of biological entities and/or the subsequent delimitation and characterization of a taxon. Taxon concepts thus frequently change during the knowledge generation process in systematic biology. Structured character data are therefore not only needed for the knowledge generation process but also for easily adapting characterizations of taxa. We aim to facilitate the construction and reproducibility of taxon characterizations from structured character data of changing sample sets by establishing a stable and unambiguous association between each sampled individual and the data processed from it. Our workflow implementation uses the European Distributed Institute of Taxonomy Platform, a comprehensive taxonomic data management and publication environment to: (i) establish a reproducible connection between sampled individuals and all samples derived from them; (ii) stably link sample-based character data with the metadata of the respective samples; (iii) record and store structured specimen-based character data in formats allowing data exchange; (iv) reversibly assign sample metadata and character datasets to taxa in an editable classification and display them and (v) organize data exchange via standard exchange formats and enable the link between the character datasets and samples in research collections, ensuring high visibility and instant re-usability of the data. The workflow implemented will contribute to organizing the interface between phylogenetic analysis and revisionary taxonomic or monographic work

  1. Ground-water sample collection and analysis plan for the ground-water surveillance project

    SciTech Connect

    Bryce, R.W.; Evans, J.C.; Olsen, K.B.

    1991-12-01

    The Pacific Northwest Laboratory performs ground-water sampling activities at the US Department of Energy`s (DOE`s) Hanford Site in support of DOE`s environmental surveillance responsibilities. The purpose of this document is to translate DOE`s General Environmental Protection Program (DOE Order 5400.1) into a comprehensive ground-water sample collection and analysis plan for the Hanford Site. This sample collection and analysis plan sets forth the environmental surveillance objectives applicable to ground water, identifies the strategy for selecting sample collection locations, and lists the analyses to be performed to meet those objectives.

  2. Ground-water sample collection and analysis plan for the ground-water surveillance project

    SciTech Connect

    Bryce, R.W.; Evans, J.C.; Olsen, K.B.

    1991-12-01

    The Pacific Northwest Laboratory performs ground-water sampling activities at the US Department of Energy's (DOE's) Hanford Site in support of DOE's environmental surveillance responsibilities. The purpose of this document is to translate DOE's General Environmental Protection Program (DOE Order 5400.1) into a comprehensive ground-water sample collection and analysis plan for the Hanford Site. This sample collection and analysis plan sets forth the environmental surveillance objectives applicable to ground water, identifies the strategy for selecting sample collection locations, and lists the analyses to be performed to meet those objectives.

  3. Extracting samples of high diversity from thematic collections of large gene banks using a genetic-distance based approach

    PubMed Central

    2010-01-01

    Background Breeding programs are usually reluctant to evaluate and use germplasm accessions other than the elite materials belonging to their advanced populations. The concept of core collections has been proposed to facilitate the access of potential users to samples of small sizes, representative of the genetic variability contained within the gene pool of a specific crop. The eventual large size of a core collection perpetuates the problem it was originally proposed to solve. The present study suggests that, in addition to the classic core collection concept, thematic core collections should be also developed for a specific crop, composed of a limited number of accessions, with a manageable size. Results The thematic core collection obtained meets the minimum requirements for a core sample - maintenance of at least 80% of the allelic richness of the thematic collection, with, approximately, 15% of its size. The method was compared with other methodologies based on the M strategy, and also with a core collection generated by random sampling. Higher proportions of retained alleles (in a core collection of equal size) or similar proportions of retained alleles (in a core collection of smaller size) were detected in the two methods based on the M strategy compared to the proposed methodology. Core sub-collections constructed by different methods were compared regarding the increase or maintenance of phenotypic diversity. No change on phenotypic diversity was detected by measuring the trait "Weight of 100 Seeds", for the tested sampling methods. Effects on linkage disequilibrium between unlinked microsatellite loci, due to sampling, are discussed. Conclusions Building of a thematic core collection was here defined by prior selection of accessions which are diverse for the trait of interest, and then by pairwise genetic distances, estimated by DNA polymorphism analysis at molecular marker loci. The resulting thematic core collection potentially reflects the maximum

  4. Adaptive Sampling-Based Information Collection for Wireless Body Area Networks.

    PubMed

    Xu, Xiaobin; Zhao, Fang; Wang, Wendong; Tian, Hui

    2016-08-31

    To collect important health information, WBAN applications typically sense data at a high frequency. However, limited by the quality of wireless link, the uploading of sensed data has an upper frequency. To reduce upload frequency, most of the existing WBAN data collection approaches collect data with a tolerable error. These approaches can guarantee precision of the collected data, but they are not able to ensure that the upload frequency is within the upper frequency. Some traditional sampling based approaches can control upload frequency directly, however, they usually have a high loss of information. Since the core task of WBAN applications is to collect health information, this paper aims to collect optimized information under the limitation of upload frequency. The importance of sensed data is defined according to information theory for the first time. Information-aware adaptive sampling is proposed to collect uniformly distributed data. Then we propose Adaptive Sampling-based Information Collection (ASIC) which consists of two algorithms. An adaptive sampling probability algorithm is proposed to compute sampling probabilities of different sensed values. A multiple uniform sampling algorithm provides uniform samplings for values in different intervals. Experiments based on a real dataset show that the proposed approach has higher performance in terms of data coverage and information quantity. The parameter analysis shows the optimized parameter settings and the discussion shows the underlying reason of high performance in the proposed approach.

  5. Adaptive Sampling-Based Information Collection for Wireless Body Area Networks

    PubMed Central

    Xu, Xiaobin; Zhao, Fang; Wang, Wendong; Tian, Hui

    2016-01-01

    To collect important health information, WBAN applications typically sense data at a high frequency. However, limited by the quality of wireless link, the uploading of sensed data has an upper frequency. To reduce upload frequency, most of the existing WBAN data collection approaches collect data with a tolerable error. These approaches can guarantee precision of the collected data, but they are not able to ensure that the upload frequency is within the upper frequency. Some traditional sampling based approaches can control upload frequency directly, however, they usually have a high loss of information. Since the core task of WBAN applications is to collect health information, this paper aims to collect optimized information under the limitation of upload frequency. The importance of sensed data is defined according to information theory for the first time. Information-aware adaptive sampling is proposed to collect uniformly distributed data. Then we propose Adaptive Sampling-based Information Collection (ASIC) which consists of two algorithms. An adaptive sampling probability algorithm is proposed to compute sampling probabilities of different sensed values. A multiple uniform sampling algorithm provides uniform samplings for values in different intervals. Experiments based on a real dataset show that the proposed approach has higher performance in terms of data coverage and information quantity. The parameter analysis shows the optimized parameter settings and the discussion shows the underlying reason of high performance in the proposed approach. PMID:27589758

  6. Adaptive Sampling-Based Information Collection for Wireless Body Area Networks.

    PubMed

    Xu, Xiaobin; Zhao, Fang; Wang, Wendong; Tian, Hui

    2016-01-01

    To collect important health information, WBAN applications typically sense data at a high frequency. However, limited by the quality of wireless link, the uploading of sensed data has an upper frequency. To reduce upload frequency, most of the existing WBAN data collection approaches collect data with a tolerable error. These approaches can guarantee precision of the collected data, but they are not able to ensure that the upload frequency is within the upper frequency. Some traditional sampling based approaches can control upload frequency directly, however, they usually have a high loss of information. Since the core task of WBAN applications is to collect health information, this paper aims to collect optimized information under the limitation of upload frequency. The importance of sensed data is defined according to information theory for the first time. Information-aware adaptive sampling is proposed to collect uniformly distributed data. Then we propose Adaptive Sampling-based Information Collection (ASIC) which consists of two algorithms. An adaptive sampling probability algorithm is proposed to compute sampling probabilities of different sensed values. A multiple uniform sampling algorithm provides uniform samplings for values in different intervals. Experiments based on a real dataset show that the proposed approach has higher performance in terms of data coverage and information quantity. The parameter analysis shows the optimized parameter settings and the discussion shows the underlying reason of high performance in the proposed approach. PMID:27589758

  7. Metabolite and Lipid Profiling of Biobank Plasma Samples Collected Prior to Onset of Rheumatoid Arthritis

    PubMed Central

    Surowiec, Izabella; Ärlestig, Lisbeth

    2016-01-01

    Objective The early diagnosis of rheumatoid arthritis (RA) is desirable to install treatment to prevent disease progression and joint destruction. Autoantibodies and immunological markers pre-date the onset of symptoms by years albeit not all patients will present these factors, even at disease onset. Additional biomarkers would be of high value to improve early diagnosis and understanding of the process, leading to disease development. Methods Plasma samples donated before the onset of RA were identified in the Biobank of Northern Sweden, a collection within national health survey programs. Thirty samples from pre-symptomatic individuals and nineteen from controls were subjected to liquid chromatography-mass spectrometry (LCMS) metabolite and lipid profiling. Lipid and metabolite profiles discriminating samples from pre-symptomatic individuals from controls were identified after univariate and multivariate OPLS-DA based analyses. Results The OPLS-DA models including pre-symptomatic individuals and controls identified profiles differentiating between the groups that was characterized by lower levels of acyl-carnitines and fatty acids, with higher levels of lysophospatidylcholines (LPCs) and metabolites from tryptophan metabolism in pre-symptomatic individuals compared with controls. Lipid profiling showed that the majority of phospholipids and sphingomyelins were at higher levels in pre-symptomatic individuals in comparison with controls. Conclusions Our LCMS based approach demonstrated that there are changes in small molecule and lipid profiles detectable in plasma samples collected from the pre-symptomatic individuals who subsequently developed RA, which point to an up-regulation of levels of lysophospatidylcholines, and of tryptophan metabolism, perturbation of fatty acid beta-oxidation and increased oxidative stress in pre-symptomatic individuals’ years before onset of symptoms. PMID:27755546

  8. Particle size distribution and chemical composition of total mixed rations for dairy cattle: water addition and feed sampling effects.

    PubMed

    Arzola-Alvarez, C; Bocanegra-Viezca, J A; Murphy, M R; Salinas-Chavira, J; Corral-Luna, A; Romanos, A; Ruíz-Barrera, O; Rodríguez-Muela, C

    2010-09-01

    Four dairy farms were used to determine the effects of water addition to diets and sample collection location on the particle size distribution and chemical composition of total mixed rations (TMR). Samples were collected weekly from the mixing wagon and from 3 locations in the feed bunk (top, middle, and bottom) for 5 mo (April, May, July, August, and October). Samples were partially dried to determine the effect of moisture on particle size distribution. Particle size distribution was measured using the Penn State Particle Size Separator. Crude protein, neutral detergent fiber, and acid detergent fiber contents were also analyzed. Particle fractions 19 to 8, 8 to 1.18, and <1.18 mm were judged adequate in all TMR for rumen function and milk yield; however, the percentage of material>19 mm was greater than recommended for TMR, according to the guidelines of Cooperative Extension of Pennsylvania State University. The particle size distribution in April differed from that in October, but intermediate months (May, July, and August) had similar particle size distributions. Samples from the bottom of the feed bunk had the highest percentage of particles retained on the 19-mm sieve. Samples from the top and middle of the feed bunk were similar to that from the mixing wagon. Higher percentages of particles were retained on >19, 19 to 8, and 8 to 1.18 mm sieves for wet than dried samples. The reverse was found for particles passing the 1.18-mm sieve. Mean particle size was higher for wet than dried samples. The crude protein, neutral detergent fiber, and acid detergent fiber contents of TMR varied with month of sampling (18-21, 40-57, and 21-34%, respectively) but were within recommended ranges for high-yielding dairy cows. Analyses of TMR particle size distributions are useful for proper feed bunk management and formulation of diets that maintain rumen function and maximize milk production and quality. Water addition may help reduce dust associated with feeding TMR. PMID

  9. Sampling strategies and post-processing methods for increasing the time resolution of organic aerosol measurements requiring long sample-collection times

    NASA Astrophysics Data System (ADS)

    Modini, Rob L.; Takahama, Satoshi

    2016-07-01

    The composition and properties of atmospheric organic aerosols (OAs) change on timescales of minutes to hours. However, some important OA characterization techniques typically require greater than a few hours of sample-collection time (e.g., Fourier transform infrared (FTIR) spectroscopy). In this study we have performed numerical modeling to investigate and compare sample-collection strategies and post-processing methods for increasing the time resolution of OA measurements requiring long sample-collection times. Specifically, we modeled the measurement of hydrocarbon-like OA (HOA) and oxygenated OA (OOA) concentrations at a polluted urban site in Mexico City, and investigated how to construct hourly resolved time series from samples collected for 4, 6, and 8 h. We modeled two sampling strategies - sequential and staggered sampling - and a range of post-processing methods including interpolation and deconvolution. The results indicated that relative to the more sophisticated and costly staggered sampling methods, linear interpolation between sequential measurements is a surprisingly effective method for increasing time resolution. Additional error can be added to a time series constructed in this manner if a suboptimal sequential sampling schedule is chosen. Staggering measurements is one way to avoid this effect. There is little to be gained from deconvolving staggered measurements, except at very low values of random measurement error (< 5 %). Assuming 20 % random measurement error, one can expect average recovery errors of 1.33-2.81 µg m-3 when using 4-8 h-long sequential and staggered samples to measure time series of concentration values ranging from 0.13-29.16 µg m-3. For 4 h samples, 19-47 % of this total error can be attributed to the process of increasing time resolution alone, depending on the method used, meaning that measurement precision would only be improved by 0.30-0.75 µg m-3 if samples could be collected over 1 h instead of 4 h. Devising a

  10. 76 FR 64366 - Notice of Proposed Information Collection for Public Comment: Additional On-Site Data Collection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-18

    ... Collection for the Housing Choice Voucher Program Administrative Fee Study AGENCY: Office of the Policy... lists the following information: Title of Proposal: Housing Choice Voucher Program Administrative...

  11. Collecting Samples in Gale Crater, Mars; an Overview of the Mars Science Laboratory Sample Acquisition, Sample Processing and Handling System

    NASA Astrophysics Data System (ADS)

    Anderson, R. C.; Jandura, L.; Okon, A. B.; Sunshine, D.; Roumeliotis, C.; Beegle, L. W.; Hurowitz, J.; Kennedy, B.; Limonadi, D.; McCloskey, S.; Robinson, M.; Seybold, C.; Brown, K.

    2012-09-01

    The Mars Science Laboratory Mission (MSL), scheduled to land on Mars in the summer of 2012, consists of a rover and a scientific payload designed to identify and assess the habitability, geological, and environmental histories of Gale crater. Unraveling the geologic history of the region and providing an assessment of present and past habitability requires an evaluation of the physical and chemical characteristics of the landing site; this includes providing an in-depth examination of the chemical and physical properties of Martian regolith and rocks. The MSL Sample Acquisition, Processing, and Handling (SA/SPaH) subsystem will be the first in-situ system designed to acquire interior rock and soil samples from Martian surface materials. These samples are processed and separated into fine particles and distributed to two onboard analytical science instruments SAM (Sample Analysis at Mars Instrument Suite) and CheMin (Chemistry and Mineralogy) or to a sample analysis tray for visual inspection. The SA/SPaH subsystem is also responsible for the placement of the two contact instruments, Alpha Particle X-Ray Spectrometer (APXS), and the Mars Hand Lens Imager (MAHLI), on rock and soil targets. Finally, there is a Dust Removal Tool (DRT) to remove dust particles from rock surfaces for subsequent analysis by the contact and or mast mounted instruments (e.g. Mast Cameras (MastCam) and the Chemistry and Micro-Imaging instruments (ChemCam)).

  12. On the asymptotic improvement of supervised learning by utilizing additional unlabeled samples - Normal mixture density case

    NASA Technical Reports Server (NTRS)

    Shahshahani, Behzad M.; Landgrebe, David A.

    1992-01-01

    The effect of additional unlabeled samples in improving the supervised learning process is studied in this paper. Three learning processes. supervised, unsupervised, and combined supervised-unsupervised, are compared by studying the asymptotic behavior of the estimates obtained under each process. Upper and lower bounds on the asymptotic covariance matrices are derived. It is shown that under a normal mixture density assumption for the probability density function of the feature space, the combined supervised-unsupervised learning is always superior to the supervised learning in achieving better estimates. Experimental results are provided to verify the theoretical concepts.

  13. Multiplex short tandem repeat amplification of low template DNA samples with the addition of proofreading enzymes.

    PubMed

    Davis, Carey P; Chelland, Lynzee A; Pavlova, Victoria R; Illescas, María J; Brown, Kelly L; Cruz, Tracey Dawson

    2011-05-01

    With <100 pg of template DNA, routine short tandem repeat (STR) analysis often fails, resulting in no or partial profiles and increased stochastic effects. To overcome this, some have investigated preamplification methods that include the addition of proofreading enzymes to the PCR cocktail. This project sought to determine whether adding proofreading polymerases directly in the STR amplification mixture would improve the reaction when little template DNA is available. Platinum Taq High Fidelity and GeneAmp High Fidelity were tested in Profiler Plus™ STR reactions alone and in combination with AmpliTaq(®) Gold. All reactions included the additional step of a post-PCR purification step. With both pristine low template DNA and casework samples, the addition of these polymerases resulted in comparable or no improvement in the STR amplification signal. Further, stochastic effects and artifacts were observed equally across all enzyme conditions. Based on these studies, the addition of these proofreading enzymes to a multiplex STR amplification is not recommended for low template DNA work.

  14. Clinical forensic sample collection techniques following consensual intercourse in volunteers - cervical canal brush compared to conventional swabs.

    PubMed

    Joki-Erkkilä, Minna; Tuomisto, Sari; Seppänen, Mervi; Huhtala, Heini; Ahola, Arja; Rainio, Juha; Karhunen, Pekka J

    2014-10-01

    The purpose of the research was to evaluate gynecological evidence collection techniques; the benefit of cervical canal brush sample compared to vaginal fornix and cervical swab samples and the time frame for detecting Y-chromosomal material QiAmp DNA Mini Kit(®) and Quantifiler Y Human Male DNA Quantification Kit(®) in adult volunteers following consensual intercourse. Eighty-four adult female volunteers following consensual intercourse were recruited for the study. By combining all sample collecting techniques, 81.0% of the volunteers were Y-DNA positive. Up to 60 h the conventional swab sampling techniques detected more Y-DNA positive samples when compared to the brush technique. However, after 60 h, the cervical canal brush sample technique showed its benefit by detecting 27.3% (6/22) of Y-DNA positive samples, which were Y-DNA negative in both conventional swab sampling techniques. By combining swab and brush techniques, 75% of the volunteers were still Y-DNA positive in 72-144 post-coital hours. The rate of measurable Y-DNA decreased approximately 3% per hour. Despite reported consensual intercourse, 6.8% (3/44) of volunteers were Y-DNA negative within 48 h. Y-DNA was not detected after 144 post-coital hours (6 days). In conclusion, the brush as a forensic evidence collection method may provide additional biological trace evidence from the cervical canal, although the best biological trace evidence collection can be obtained by combining all three sampling techniques. The time frame for gynecological forensic evidence sample collection should be considered to be at least a week if sexual violence is suspected.

  15. Human breath analysis: methods for sample collection and reduction of localized background effects.

    PubMed

    Martin, Audrey N; Farquar, George R; Jones, A Daniel; Frank, Matthias

    2010-01-01

    Solid-phase microextraction (SPME) was applied, in conjunction with gas chromatography-mass spectrometry, to the analysis of volatile organic compounds (VOCs) in human breath samples without requiring exhaled breath condensate collection. A new procedure, exhaled breath vapor (EBV) collection, involving the active sampling and preconcentration of a breath sample with a SPME fiber fitted inside a modified commercial breath-collection device, the RTube, is described. Immediately after sample collection, compounds are desorbed from the SPME fiber at 250 degrees C in the GC-MS injector. Experiments were performed using EBV collected at -80 degrees C and at room temperature, and the results compared to the traditional method of collecting exhaled breath condensate at -80 degrees C followed by passive SPME sampling of the collected condensate. Methods are compared in terms of portability, ease-of-use, speed of analysis, and detection limits. The need for a clean air supply for the study subjects is demonstrated using several localized sources of VOC contaminants including nail polish, lemonade, and gasoline. Various simple methods to supply clean inhaled air to a subject are presented. Chemical exposures are used to demonstrate the importance of providing cleaned air (organic vapor respirator) or an external air source (tubing stretched to a separate room). These techniques allow for facile data interpretation by minimizing background contaminants. It is demonstrated herein that this active SPME breath-sampling device provides advantages in the forms of faster sample collection and data analysis, apparatus portability and avoidance of power or cooling requirements, and performance for sample collection in a contaminated environment. PMID:19844696

  16. A Review of Metal Concentrations Measured in Surface Soil Samples Collected on and Around the Hanford Site

    SciTech Connect

    Fritz, Brad G.

    2009-07-27

    The data used in this report was collected by two separate projects. The Surface Environmental Surveillance Project collected routine samples in 2008 at 41 locations on and around the Hanford Site, and had them analyzed for metals in addition to the normal radiological constituents. In 2004 and 2005, soil samples were collected at 117 locations on the Hanford Reach National Monument (HRNM) in support of the radiological release of that property. In 2008, archived HRNM soil samples were analyzed for metals to supplement the radiological analyses. Concentration results for 30 individual metals were generated by the analytical methods. Selenium and antimony were not measured at detectable concentrations in most of the samples. Mercury was detected in about half of the samples analyzed. All other constituents were measured at detectable concentrations in nearly all samples analyzed. The average concentrations measured in this study were well below the soil cleanup levels for unrestricted land use established by the Model Toxics Control Act (MTCA). In addition to the average concentration being less than the benchmark, the 90th percentile concentration was also lower than the benchmark for the metals included in the MTCA. The results indicate that the measured concentrations of metals in surface soil were within the expected natural range of concentrations.

  17. Mars Rover Sample Return: A sample collection and analysis strategy for exobiology

    NASA Technical Reports Server (NTRS)

    Sims, M. H.; Fischler, M.; Schwartz, D. E.; Rosenthal, Donald A.; Mancinelli, Rocco L.; Nedell, Susan S.; Gamble, E.; Mckay, Christopher P.

    1989-01-01

    For reasons defined elsewhere it is reasonable to search for biological signatures, both chemical and morphological, of extinct life on Mars. Life on Earth requries the presence of liquid water, therefore, it is important to explore sites on Mars where standing bodies of water may have once existed. Outcrops of layered deposits within the Valles Marineris appear to be ancient lake beds. Because the outcrops are well exposed, relatively shallow core samples would be very informative. The most important biological signature to detect would be organics, microfossils, or larger stromato-like structures, although the presence of cherts, carbonates, clays, and shales would be significant. In spite of the limitations of current robotics and pattern recognition, and the limitations of rover power, computation, Earth communication bandwidth, and time delays, a partial scenario was developed to implement such a scientific investigation. The rover instrumentation and the procedures and decisions and IR spectrometer are described in detail. Preliminary results from a collaborative effort are described, which indicate the rover will be able to autonomously detect stratification, and hence will ease the interpretation burden and lead to greater scientific productivity during the rover's lifetime.

  18. Occurrence of Leptospira DNA in water and soil samples collected in eastern Poland.

    PubMed

    Wójcik-Fatla, Angelina; Zając, Violetta; Wasiński, Bernard; Sroka, Jacek; Cisak, Ewa; Sawczyn, Anna; Dutkiewicz, Jacek

    2014-01-01

    Leptospira is an important re-emerging zoonotic human pathogen, disseminated by sick and carrier animals, water and soil. Weather calamities, such as flooding or cyclones favour the spreading of these bacteria. To check a potential role of natural water and soil in the persistence and spread of Leptospira on the territory of eastern Poland, 40 samples of natural water and 40 samples of soil were collected from areas exposed to flooding, and 64 samples of natural water and 68 samples of soil were collected from areas not exposed to flooding. Samples of water were taken from various reservoirs (rivers, natural lakes, artificial lakes, canals, ponds, farm wells) and samples of soils were taken at the distance of 1-3 meters from the edge of the reservoirs. The samples were examined for the presence of Leptospira DNA by nested-PCR. Two out of 40 samples of water (5.0%) collected from the area exposed to flooding showed the presence of Leptospira DNA, while all 40 samples of soil from this area were negative. All samples of water and soil (64 and 68, respectively) collected from the areas not exposed to flooding were negative. No significant difference were found between the results obtained in the areas exposed and not exposed to flooding. In conclusion, these results suggest that water and soil have only limited significance in the persistence and dissemination of Leptospira in eastern Poland. PMID:25528911

  19. The representativeness of pore water samples collected from the unsaturated zone using pressure-vacuum lysimeters

    USGS Publications Warehouse

    Peters, C.A.; Healy, R.W.

    1988-01-01

    Studies have indicated that the chemistry of water samples may be altered by the collection technique, creating concern about the representativeness of the pore water samples obtained. A study using soil water pressure-vacuum lysimeters in outwash sand and glacial till deposits demonstrates that for non-dilute-solution samples the effect of pH of sampling with lysimeters is minimal, and that measured major cation and anion concentrations are representative of the natural pore water; trace-metal concentrations can be significantly altered by collection procedures at low concentrations. -from Authors

  20. DISTRIBUTION COEFICIENTS (KD) GENERATED FROM A CORE SAMPLE COLLECTED FROM THE SALTSTONE DISPOSAL FACILITY

    SciTech Connect

    Almond, P.; Kaplan, D.

    2011-04-25

    Core samples originating from Vault 4, Cell E of the Saltstone Disposal Facility (SDF) were collected in September of 2008 (Hansen and Crawford 2009, Smith 2008) and sent to SRNL to measure chemical and physical properties of the material including visual uniformity, mineralogy, microstructure, density, porosity, distribution coefficients (K{sub d}), and chemical composition. Some data from these experiments have been reported (Cozzi and Duncan 2010). In this study, leaching experiments were conducted with a single core sample under conditions that are representative of saltstone performance. In separate experiments, reducing and oxidizing environments were targeted to obtain solubility and Kd values from the measurable species identified in the solid and aqueous leachate. This study was designed to provide insight into how readily species immobilized in saltstone will leach from the saltstone under oxidizing conditions simulating the edge of a saltstone monolith and under reducing conditions, targeting conditions within the saltstone monolith. Core samples were taken from saltstone poured in December of 2007 giving a cure time of nine months in the cell and a total of thirty months before leaching experiments began in June 2010. The saltstone from Vault 4, Cell E is comprised of blast furnace slag, class F fly ash, portland cement, and Deliquification, Dissolution, and Adjustment (DDA) Batch 2 salt solution. The salt solution was previously analyzed from a sample of Tank 50 salt solution and characterized in the 4QCY07 Waste Acceptance Criteria (WAC) report (Zeigler and Bibler 2009). Subsequent to Tank 50 analysis, additional solution was added to the tank solution from the Effluent Treatment Project as well as from inleakage from Tank 50 pump bearings (Cozzi and Duncan 2010). Core samples were taken from three locations and at three depths at each location using a two-inch diameter concrete coring bit (1-1, 1-2, 1-3; 2-1, 2-2, 2-3; 3-1, 3-2, 3-3) (Hansen and

  1. Vacuum hand pump apparatus for collecting water samples from a horizontal intragravel pipe

    USGS Publications Warehouse

    Saiki, Michael K.; Martin, Barbara A.

    1996-01-01

    We describe a lightweight, portable vacuum hand pump apparatus for use in collecting water samples from horizontal intragravel pipe samplers buried in the stream bottom. The apparatus is easily fabricated from relatively inexpensive materials available at many laboratory supply houses.

  2. Validation of a Novel Collection Device for Non-Invasive Urine Sampling from Free-Ranging Animals

    PubMed Central

    Danish, Lisa Michelle; Heistermann, Michael; Agil, Muhammad; Engelhardt, Antje

    2015-01-01

    Recent advances in non-invasively collected samples have opened up new and exciting opportunities for wildlife research. Different types of samples, however, involve different limitations and certain physiological markers (e.g., C-peptide, oxytocin) can only be reliably measured from urine. Common collection methods for urine to date work best for arboreal animals and large volumes of urine. Sufficient recovery of urine is thus still difficult for wildlife biologists, particularly for terrestrial and small bodied animals. We tested three collection devices (two commercially available saliva swabs, Salivette synthetic and cotton, and cotton First aid swabs) against a control to permit the collection of small volumes of urine from the ground. We collected urine samples from captive and wild macaques, and humans, measured volume recovery, and analyzed concentrates of selected physiological markers (creatinine, C-peptide, and neopterin). The Salivette synthetic device was superior to the two alternative devices. Concentrations of creatinine, absolute C-peptide, C-peptide per creatinine, absolute neopterin, and neopterin per creatinine measured in samples collected with this device did not differ significantly from the control and were also strongly correlated to it. Fluid recovery was also best for this device. The least suitable device is the First aid collection device; we found that while absolute C-peptide and C-peptide per creatinine concentrations did not differ significantly from the control, creatinine concentrations were significantly lower than the control. In addition, these concentrations were either not or weakly correlated to the control. The Salivette cotton device provided intermediate results, although these concentrations were strongly correlated to the control. Salivette synthetic swabs seem to be useful devices for the collection of small amounts of urine from the ground destined for the assessment of physiological parameters. They thus provide new

  3. The Internet of Samples in the Earth Sciences: Providing Access to Uncurated Collections

    NASA Astrophysics Data System (ADS)

    Carter, M. R.; Lehnert, K. A.

    2014-12-01

    Vast amounts of physical samples have been collected in the Earth Sciences for studies that address a wide range of scientific questions. Only a fraction of these samples are well curated and preserved long-term in sample repositories and museums. Many samples and collections are stored in the offices and labs of investigators, or in basements and sheds of institutions and investigators' homes. These 'uncurated' collections often contain samples that have been well studied, or are unique and irreplaceable. They may also include samples that could reveal new insights if re-analyzed using new techniques, or specimens that could have unanticipated relevance to research being conducted in fields other than the one for which they were collected. Currently, these samples cannot be accessed or discovered online by the broader science community. Investigators and departments often lack the resources to properly catalog and curate the samples and respond to requests for splits. Long-term preservation of and access to these samples is usually not provided for. iSamplES, a recently-funded EarthCube Research Coordination Network (RCN), seeks to integrate scientific samples, including 'uncurated' samples, into digital data and information infrastructure in the Earth Sciences and to facilitate their curation, discovery, access, sharing, and analysis. The RCN seeks to develop and implement best practices that increase digital access to samples with the goal of establishing a comprehensive infrastructure not only for the digital, but also physical curation of samples. The RCN will engage a broad group of individuals from domain scientists to curators to publishers to computer scientists to define, articulate, and address the needs and challenges of digital sample management and recommend community-endorsed best practices and standards for registering, describing, identifying, and citing physical specimens, drawing upon other initiatives and existing or emerging software tools for

  4. 9 CFR 147.12 - Procedures for collection, isolation, and identification of Salmonella from environmental samples...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... common; e.g., on or near waterers, feeders, nests, or rafters, etc. When the volume of material collected... of fecal material, litter, or dust in a sterile, sealable container. The sample shall consist of several specimens of material taken from a representative location in the pen or house. Collect at...

  5. OSIRIS-REx Touch-and-Go (TAG) Mission Design for Asteroid Sample Collection

    NASA Technical Reports Server (NTRS)

    May, Alexander; Sutter, Brian; Linn, Timothy; Bierhaus, Beau; Berry, Kevin; Mink, Ron

    2014-01-01

    The Origins Spectral Interpretation Resource Identification Security Regolith Explorer (OSIRIS-REx) mission is a NASA New Frontiers mission launching in September 2016 to rendezvous with the near-Earth asteroid Bennu in October 2018. After several months of proximity operations to characterize the asteroid, OSIRIS-REx flies a Touch-And-Go (TAG) trajectory to the asteroid's surface to collect at least 60 g of pristine regolith sample for Earth return. This paper provides mission and flight system overviews, with more details on the TAG mission design and key events that occur to safely and successfully collect the sample. An overview of the navigation performed relative to a chosen sample site, along with the maneuvers to reach the desired site is described. Safety monitoring during descent is performed with onboard sensors providing an option to abort, troubleshoot, and try again if necessary. Sample collection occurs using a collection device at the end of an articulating robotic arm during a brief five second contact period, while a constant force spring mechanism in the arm assists to rebound the spacecraft away from the surface. Finally, the sample is measured quantitatively utilizing the law of conservation of angular momentum, along with qualitative data from imagery of the sampling device. Upon sample mass verification, the arm places the sample into the Stardust-heritage Sample Return Capsule (SRC) for return to Earth in September 2023.

  6. Examination of microbial proteome preservation techniques applicable to autonomous environmental sample collection.

    PubMed

    Saito, Mak A; Bulygin, Vladimir V; Moran, Dawn M; Taylor, Craig; Scholin, Chris

    2011-01-01

    Improvements in temporal and spatial sampling frequency have the potential to open new windows into the understanding of marine microbial dynamics. In recent years, efforts have been made to allow automated samplers to collect microbial biomass for DNA/RNA analyses from moored observatories and autonomous underwater vehicles. Measurements of microbial proteins are also of significant interest given their biogeochemical importance as enzymes that catalyze reactions and transporters that interface with the environment. We examined the influence of five preservatives solutions (SDS-extraction buffer, ethanol, trichloroacetic acid, B-PER, and RNAlater) on the proteome integrity of the marine cyanobacterium Synechococcus WH8102 after 4 weeks of storage at room temperature. Four approaches were used to assess degradation: total protein recovery, band integrity on an SDS detergent polyacrylamide electrophoresis (SDS-PAGE) gel, and number of protein identifications and relative abundances by 1-dimensional LC-MS/MS proteomic analyses. Total protein recoveries from the preserved samples were lower than the frozen control due to processing losses, which could be corrected for with internal standardization. The trichloroacetic acid preserved sample showed significant loss of protein band integrity on the SDS-PAGE gel. The RNAlater preserved sample showed the highest number of protein identifications (103% relative to the control; 520 ± 31 identifications in RNAlater versus 504 ± 4 in the control), equivalent to the frozen control. Relative abundances of individual proteins in the RNAlater treatment were quite similar to that of the frozen control (average ratio of 1.01 ± 0.27 for the 50 most abundant proteins), while the SDS-extraction buffer, ethanol, and B-PER all showed significant decreases in both number of identifications and relative abundances of individual proteins. Based on these findings, RNAlater was an effective proteome preservative, although

  7. 76 FR 80377 - Notice of Submission of Proposed Information Collection to OMB Additional On-Site Data Collection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-23

    ... below has been submitted to the Office of Management and Budget (OMB) for review, as required by the...-performing and efficient HCV programs. The proposed data collection will take place through site visits to up...: HUD Desk Officer, Office of Management and Budget, New Executive Office Building, Washington, DC...

  8. Efficiency of Different Sampling Tools for Aquatic Macroinvertebrate Collections in Malaysian Streams.

    PubMed

    Ghani, Wan Mohd Hafezul Wan Abdul; Rawi, Che Salmah Md; Hamid, Suhaila Abd; Al-Shami, Salman Abdo

    2016-02-01

    This study analyses the sampling performance of three benthic sampling tools commonly used to collect freshwater macroinvertebrates. Efficiency of qualitative D-frame and square aquatic nets were compared to a quantitative Surber sampler in tropical Malaysian streams. The abundance and diversity of macroinvertebrates collected using each tool evaluated along with their relative variations (RVs). Each tool was used to sample macroinvertebrates from three streams draining different areas: a vegetable farm, a tea plantation and a forest reserve. High macroinvertebrate diversities were recorded using the square net and Surber sampler at the forested stream site; however, very low species abundance was recorded by the Surber sampler. Relatively large variations in the Surber sampler collections (RVs of 36% and 28%) were observed for the vegetable farm and tea plantation streams, respectively. Of the three sampling methods, the square net was the most efficient, collecting a greater diversity of macroinvertebrate taxa and a greater number of specimens (i.e., abundance) overall, particularly from the vegetable farm and the tea plantation streams (RV<25%). Fewer square net sample passes (<8 samples) were sufficient to perform a biological assessment of water quality, but each sample required a slightly longer processing time (±20 min) compared with those gathered via the other samplers. In conclusion, all three apparatuses were suitable for macroinvertebrate collection in Malaysian streams and gathered assemblages that resulted in the determination of similar biological water quality classes using the Family Biotic Index (FBI) and the Biological Monitoring Working Party (BMWP). However, despite a slightly longer processing time, the square net was more efficient (lowest RV) at collecting samples and more suitable for the collection of macroinvertebrates from deep, fast flowing, wadeable streams with coarse substrates.

  9. Efficiency of Different Sampling Tools for Aquatic Macroinvertebrate Collections in Malaysian Streams.

    PubMed

    Ghani, Wan Mohd Hafezul Wan Abdul; Rawi, Che Salmah Md; Hamid, Suhaila Abd; Al-Shami, Salman Abdo

    2016-02-01

    This study analyses the sampling performance of three benthic sampling tools commonly used to collect freshwater macroinvertebrates. Efficiency of qualitative D-frame and square aquatic nets were compared to a quantitative Surber sampler in tropical Malaysian streams. The abundance and diversity of macroinvertebrates collected using each tool evaluated along with their relative variations (RVs). Each tool was used to sample macroinvertebrates from three streams draining different areas: a vegetable farm, a tea plantation and a forest reserve. High macroinvertebrate diversities were recorded using the square net and Surber sampler at the forested stream site; however, very low species abundance was recorded by the Surber sampler. Relatively large variations in the Surber sampler collections (RVs of 36% and 28%) were observed for the vegetable farm and tea plantation streams, respectively. Of the three sampling methods, the square net was the most efficient, collecting a greater diversity of macroinvertebrate taxa and a greater number of specimens (i.e., abundance) overall, particularly from the vegetable farm and the tea plantation streams (RV<25%). Fewer square net sample passes (<8 samples) were sufficient to perform a biological assessment of water quality, but each sample required a slightly longer processing time (±20 min) compared with those gathered via the other samplers. In conclusion, all three apparatuses were suitable for macroinvertebrate collection in Malaysian streams and gathered assemblages that resulted in the determination of similar biological water quality classes using the Family Biotic Index (FBI) and the Biological Monitoring Working Party (BMWP). However, despite a slightly longer processing time, the square net was more efficient (lowest RV) at collecting samples and more suitable for the collection of macroinvertebrates from deep, fast flowing, wadeable streams with coarse substrates. PMID:27019685

  10. Efficiency of Different Sampling Tools for Aquatic Macroinvertebrate Collections in Malaysian Streams

    PubMed Central

    Ghani, Wan Mohd Hafezul Wan Abdul; Rawi, Che Salmah Md; Hamid, Suhaila Abd; Al-Shami, Salman Abdo

    2016-01-01

    This study analyses the sampling performance of three benthic sampling tools commonly used to collect freshwater macroinvertebrates. Efficiency of qualitative D-frame and square aquatic nets were compared to a quantitative Surber sampler in tropical Malaysian streams. The abundance and diversity of macroinvertebrates collected using each tool evaluated along with their relative variations (RVs). Each tool was used to sample macroinvertebrates from three streams draining different areas: a vegetable farm, a tea plantation and a forest reserve. High macroinvertebrate diversities were recorded using the square net and Surber sampler at the forested stream site; however, very low species abundance was recorded by the Surber sampler. Relatively large variations in the Surber sampler collections (RVs of 36% and 28%) were observed for the vegetable farm and tea plantation streams, respectively. Of the three sampling methods, the square net was the most efficient, collecting a greater diversity of macroinvertebrate taxa and a greater number of specimens (i.e., abundance) overall, particularly from the vegetable farm and the tea plantation streams (RV<25%). Fewer square net sample passes (<8 samples) were sufficient to perform a biological assessment of water quality, but each sample required a slightly longer processing time (±20 min) compared with those gathered via the other samplers. In conclusion, all three apparatuses were suitable for macroinvertebrate collection in Malaysian streams and gathered assemblages that resulted in the determination of similar biological water quality classes using the Family Biotic Index (FBI) and the Biological Monitoring Working Party (BMWP). However, despite a slightly longer processing time, the square net was more efficient (lowest RV) at collecting samples and more suitable for the collection of macroinvertebrates from deep, fast flowing, wadeable streams with coarse substrates. PMID:27019685

  11. Adsorptive Films in Support of In-field UF6 Destructive Assay Sample Collection and Analysis

    SciTech Connect

    Barrett, Christopher A.; Martinez, Alonzo; McNamara, Bruce K.; Cannon, Bret D.; Anheier, Norman C.

    2014-07-20

    International Atom Energy Agency (IAEA) safeguard verification measures in gaseous centrifuge enrichment plants (GCEPs) rely on environmental sampling, non-destructive assay (NDA), and destructive assay (DA) sampling and analysis to determine uranium enrichment. UF6 bias defect measurements are made by DA sampling and analysis to assure that enrichment is consistent with declarations. DA samples are collected from a limited number of cylinders for high precision, offsite mass spectrometer analysis. Samples are typically drawn from a sampling tap into a UF6 sample bottle, then packaged, sealed, and shipped under IAEA chain of custody to an offsite analytical laboratory. Future DA safeguard measures may require improvements in efficiency and effectiveness as GCEP capacities increase and UF6 shipping regulations become increasingly more restrictive. The Pacific Northwest National Laboratory (PNNL) DA sampler concept and Laser Ablation Absorption Ratio Spectrometry (LAARS) assay method are under development to potentially provide DA safeguard tools that increase inspection effectiveness and reduce sample shipping constraints. The PNNL DA sampler concept uses a handheld sampler to collect DA samples for either onsite LAARS assay or offsite laboratory analysis. The DA sampler design will use a small sampling planchet that is coated with an adsorptive film to collect controlled quantities of UF6 gas directly from a cylinder or process sampling tap. Development efforts are currently underway at PNNL to enhance LAARS assay performance to allow high-precision onsite bias defect measurements. In this paper, we report on the experimental investigation to develop adsorptive films for the PNNL DA sampler concept. These films are intended to efficiently capture UF6 and then stabilize the collected DA sample prior to onsite LAARS or offsite laboratory analysis. Several porous material composite films were investigated, including a film designed to maximize the chemical adsorption

  12. Collecting, archiving and processing DNA from wildlife samples using FTA® databasing paper

    PubMed Central

    Smith, LM; Burgoyne, LA

    2004-01-01

    Background Methods involving the analysis of nucleic acids have become widespread in the fields of traditional biology and ecology, however the storage and transport of samples collected in the field to the laboratory in such a manner to allow purification of intact nucleic acids can prove problematical. Results FTA® databasing paper is widely used in human forensic analysis for the storage of biological samples and for purification of nucleic acids. The possible uses of FTA® databasing paper in the purification of DNA from samples of wildlife origin were examined, with particular reference to problems expected due to the nature of samples of wildlife origin. The processing of blood and tissue samples, the possibility of excess DNA in blood samples due to nucleated erythrocytes, and the analysis of degraded samples were all examined, as was the question of long term storage of blood samples on FTA® paper. Examples of the end use of the purified DNA are given for all protocols and the rationale behind the processing procedures is also explained to allow the end user to adjust the protocols as required. Conclusions FTA® paper is eminently suitable for collection of, and purification of nucleic acids from, biological samples from a wide range of wildlife species. This technology makes the collection and storage of such samples much simpler. PMID:15072582

  13. 77 FR 36567 - Agency Information Collection Activities: Application and Approval To Manipulate, Examine, Sample...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-19

    ... Approval To Manipulate, Examine, Sample, or Transfer Goods AGENCY: U.S. Customs and Border Protection (CBP... burden, CBP invites the general public and other Federal agencies to comment on an information collection requirement concerning the: Application and Approval to Manipulate, Examine, Sample, or Transfer Goods....

  14. Soil sample collection and analysis for the Fugitive Dust Characterization Study

    NASA Astrophysics Data System (ADS)

    Ashbaugh, Lowell L.; Carvacho, Omar F.; Brown, Michael S.; Chow, Judith C.; Watson, John G.; Magliano, Karen C.

    A unique set of soil samples was collected as part of the Fugitive Dust Characterization Study. The study was carried out to establish whether or not source profiles could be constructed using novel analytical methods that could distinguish soil dust sources from each other. The soil sources sampled included fields planted in cotton, almond, tomato, grape, and safflower, dairy and feedlot facilities, paved and unpaved roads (both urban and rural), an agricultural staging area, disturbed land with salt buildup, and construction areas where the topsoil had been removed. The samples were collected using a systematic procedure designed to reduce sampling bias, and were stored frozen to preserve possible organic signatures. For this paper the samples were characterized by particle size (percent sand, silt, and clay), dry silt content (used in EPA-recommended fugitive dust emission factors), carbon and nitrogen content, and potential to emit both PM 10 and PM 2.5. These are not the "novel analytical methods" referred to above; rather, it was the basic characterization of the samples to use in comparing analytical methods by other scientists contracted to the California Air Resources Board. The purpose of this paper is to document the methods used to collect the samples, the collection locations, the analysis of soil type and potential to emit PM 10, and the sample variability, both within field and between fields of the same crop type.

  15. Two red blood cell units collected in SAG-M additive solution with the ALYX component collection system.

    PubMed

    Schooneman, F; Huart, J J; Dernis, D; Tunez, V; Aguettaz, D

    2005-06-01

    The first protocol available for the new ALYX component system (Baxter Healthcare Inc.) allows automated collection of two Red Blood Cell (RBC) units from one donor. The primary objective of our evaluation was to assess donor safety, comfort and to check the quality of blood products collected. 30 procedures were performed on eligible donors according to French best donation practices. Eligibility criteria were defined in order to ensure a post donation hemoglobin concentration of 11 g/dL minimum. Pre donation ferritin level was also checked. 360 ml of absolute RBC were collected from each donor. Donors physiological parameters and haematological profile were measured immediately before and after donation. Adverse events and donors were observed during the procedure and followed daily during 5 days after donation. Hemolysis in RBC was followed until of shelf life (<0.8% on 42 days storage). The evaluation of different parameters during storage show no difference if we compare with the manual technique. The concentration of hemoglobin is good and all ou concentrates are conform. No serious adverse effects were reported during and after donation. All donors confirmed they would agree to donate 2 RBC units again with this system. We have seen a good quality of RBC products. This evaluation indicates that 2 RBC donation is feasible on the ALYX system, comfortable and safe for eligible donors.

  16. Fast egg collection method greatly improves randomness of egg sampling in Drosophila melanogaster.

    PubMed

    Schou, Mads Fristrup

    2013-01-01

    When obtaining samples for population genetic studies, it is essential that the sampling is random. For Drosophila, one of the crucial steps in sampling experimental flies is the collection of eggs. Here an egg collection method is presented, which randomizes the eggs in a water column and diminishes environmental variance. This method was compared with a traditional egg collection method where eggs are collected directly from the medium. Within each method the observed and expected standard deviations of egg-to-adult viability were compared, whereby the difference in the randomness of the samples between the two methods was assessed. The method presented here was superior to the traditional method. Only 14% of the samples had a standard deviation higher than expected, as compared with 58% in the traditional method. To reduce bias in the estimation of the variance and the mean of a trait and to obtain a representative collection of genotypes, the method presented here is strongly recommended when collecting eggs from Drosophila.

  17. Human Exploration of Near-Earth Asteroids and Sample Collection Considerations

    NASA Technical Reports Server (NTRS)

    Abell, Paul

    2013-01-01

    primitive body would lead to the same kind of breakthroughs for understanding NEAs that the Apollo samples provided for understanding the Earth-Moon system and its formation history. International Participation: In addition, robotic precursor and human exploration missions to NEAs would allow the NASA and its international partners to gain operational experience in performing complex tasks (e.g., sample collection, deployment of payloads, retrieval of payloads, etc.) with crew, robots, and spacecraft under microgravity conditions at or near the surface of a small body. This would provide an important synergy between the worldwide Science and Exploration communities, which will be crucial for development of future international deep space exploration architectures and has potential benefits for future exploration of other destinations beyond low-Earth orbit.

  18. Comparison of surgical and endoscopic sample collection for pancreatic cyst fluid biomarker identification.

    PubMed

    Partyka, Katie; McDonald, Mitchell; Maupin, Kevin A; Brand, Randall; Kwon, Richard; Simeone, Diane M; Allen, Peter; Haab, Brian B

    2012-05-01

    Significant efforts are underway to develop new biomarkers from pancreatic cyst fluid. Previous research has made use of cyst fluid collected from surgically removed cysts, but the clinical implementation of biomarkers would use cyst fluid collected by endoscopic ultrasound-guided, fine-needle aspiration (EUS-FNA). The purpose of this study was to investigate the clinical applicability of cyst fluid research obtained using surgical specimens. Matched pairs of operating-room collected (OR) and EUS-FNA samples from 12 patients were evaluated for the levels of three previously described biomarkers, CA 19-9, CEA, and glycan levels detected by wheat germ agglutinin on MUC5AC (MUC5AC-WGA). CA 19-9 and MUC5AC-WGA correlated well between the sample types, although CEA was more variable between the sample types for certain patients. The variability was not due to the time delay between EUS-FNA and OR collection or differences in total protein concentrations but may be caused by contamination of the cyst fluid with blood proteins. The classification of each patient based on thresholds for each marker was perfectly consistent between sample types for CA 19-9 and MUC5AC-WGA and mostly consistent for CEA. Therefore, results obtained using OR-collected pancreatic cyst fluid samples should reliably transfer to the clinical setting using EUS-FNA samples.

  19. Collecting Comet Samples by ER-2 Aircraft: Cosmic Dust Collection During the Draconid Meteor Shower in October 2012

    NASA Technical Reports Server (NTRS)

    Bastien, Ron; Burkett, P. J.; Rodriquez, M.; Frank, D.; Gonzalez, C.; Robinson, G.-A.; Zolensky, M.; Brown, P.; Campbell-Brown, M.; Broce, S.; Kapitzke, M.; Moes, T.; Steel, D.; Williams, T.; Gearheart, D.

    2014-01-01

    Many tons of dust grains, including samples of asteroids and comets, fall from space into the Earth's atmosphere each day. NASA periodically collects some of these particles from the Earth's stratosphere using sticky collectors mounted on NASA's high-flying aircraft. Sometimes, especially when the Earth experiences a known meteor shower, a special opportunity is presented to associate cosmic dust particles with a known source. NASA JSC's Cosmic Dust Collection Program has made special attempts to collect dust from particular meteor showers and asteroid families when flights can be planned well in advance. However, it has rarely been possible to make collections on very short notice. In 2012, the Draconid meteor shower presented that opportunity. The Draconid meteor shower, originating from Comet 21P/Giacobini-Zinner, has produced both outbursts and storms several times during the last century, but the 2012 event was not predicted to be much of a show. Because of these predictions, the Cosmic Dust team had not targeted a stratospheric collection effort for the Draconids, despite the fact that they have one of the slowest atmospheric entry velocities (23 km/s) of any comet shower, and thus offer significant possibilities of successful dust capture. However, radar measurements obtained by the Canadian Meteor Orbit Radar during the 2012 Draconids shower indicated a meteor storm did occur October 8 with a peak at 16:38 (+/-5 min) UTC for a total duration of approximately 2 hours.

  20. Magnetic Properties of Lunar Samples: an Exhaustive Survey of the Apollo Collection

    NASA Astrophysics Data System (ADS)

    Gattacceca, J.; Andrade Lima, E.; Rochette, P.; Weiss, B. P.; Uehara, M.; Quesnel, Y.; Baratchart, L.; Leblond, J.; Chevillard, S.

    2014-12-01

    Detailed paleomagnetic studies of lunar samples shed light on the existence and timing of the ancient lunar dynamo, with insights to the inner structure and thermal evolution of the Moon, as well as constraints for the lunar dynamo models [e.g., 1-6]. However these studies are usually performed on small cm-scale samples, typically below 100 mg. Such a small size, combined with anisotropy and other spurious effects have been shown to be the source of additional complexity [7]. We measured the natural remanent magnetization and magnetic susceptibility of 105 large Apollo samples (mass range 40 g to 2.9 kg, median mass 350 g). For this, following the approach utilized for the initial paleomagnetic evaluation of Apollo 11 samples [8], we developed a dedicated magnetometer using a fluxgate sensor and a rotating stage, which allowed measuring the bulk samples in their original Teflon and aluminum packaging under nitrogen atmosphere. Despite a number of caveats (no demagnetization steps, existence of viscous magnetization and other soft secondary magnetization), the ratio of natural remanent magnetization to susceptibility gives a rough estimate of the paleointensity. The evolution of the paleointensity with the estimated age of the samples will provide a broad picture of the evolution of the lunar dynamo. Susceptibility, as a proxy to the bulk metal content in lunar rocks [9], is also a valuable source of information per se but is currently available only for a small fraction of the Apollo collection. Our survey will allow identification of rocks with unusual magnetic properties, and therefore potentially unusual petrogenesis. References: [1] Fuller & Cisowski 1987. In Jacobs (Ed.) Geomagnetism, 307-455 [2] Garrick-Bethell et al. 2009. Science 323:356-359 [3] Cournède et al. 2012. EPSL 33:31-42 [4] Shea et al. 2012. Science 335:453-456 [5] Suavet et al. 2013. PNAS 110:8453-8456 [6] Tikoo et al. 2014. EPSL in press [7] Tikoo et al. 2012. EPSL 337:93-103 [8] Doell & Gromm

  1. Analyses of tipple and delivered samples of coal collected during fiscal year 1985

    SciTech Connect

    Schultz, H.; Retcofsky, H.L.; Davis, L.R.

    1988-01-01

    This Department of Energy (DOE) publication updates a series of Topical Reports (formerly ''Reports of Investigation'') on the quality of coal purchases under specifications for government use. Listed in alphabetical order by state, county, town, and mine are analytical data on the composition and quality of tipple and delivered samples of coal collected during the fiscal year 1985. Tipple samples were collected by certified commercial laboratories in accordance with instructions given by the Analytical Research Branch (ARB), Coal Science Division (CSD). The delivered samples were collected at destination by installation personnel, and all samples were analyzed under the supervision of the DOE-CSD located at the Pittsburgh Energy Technology Center (PETC), Pittsburgh, Pennsylvania, or the US Army General Material and Petroleum Activity Laboratory, located at New Cumberland, Pennsylvania.

  2. The CERN antiproton source: Controls aspects of the additional collector ring and fast sampling devices

    NASA Astrophysics Data System (ADS)

    Chohan, V.

    1990-08-01

    The upgrade of the CERN antiproton source, meant to gain an order of magnitude in antiproton flux, required the construction of an additional ring to complement the existing antiproton accumulator (AA) and an entire rebuild of the target zone. The AA also needed major modifications to handle the increased flux and perform purely as an accumulator, preceded by collection in the collector ring (AC). The upgrade, known as the ACOL (antiproton collector) project, was approved under strict time and budgetary constraints and the existing AA control system, based on the Proton Synchrotron (PS) Divisional norms of CAMAC and Norsk-Data computers, had to be extended in the light of this. The limited (9 months) installation period for the whole upgrade meant that substantial preparatory and planning activities had to be carried out during the normal running of the AA. Advantage was taken of the upgrade to improve and consolidate the AA. Some aspects of the control system related to this upgrade are discussed together with the integration of new applications and instrumentation. The overall machine installation and running-in was carried out within the defined milestones and the project has now achieved the physics design goals.

  3. JSC Advanced Curation: Research and Development for Current Collections and Future Sample Return Mission Demands

    NASA Technical Reports Server (NTRS)

    Fries, M. D.; Allen, C. C.; Calaway, M. J.; Evans, C. A.; Stansbery, E. K.

    2015-01-01

    Curation of NASA's astromaterials sample collections is a demanding and evolving activity that supports valuable science from NASA missions for generations, long after the samples are returned to Earth. For example, NASA continues to loan hundreds of Apollo program samples to investigators every year and those samples are often analyzed using instruments that did not exist at the time of the Apollo missions themselves. The samples are curated in a manner that minimizes overall contamination, enabling clean, new high-sensitivity measurements and new science results over 40 years after their return to Earth. As our exploration of the Solar System progresses, upcoming and future NASA sample return missions will return new samples with stringent contamination control, sample environmental control, and Planetary Protection requirements. Therefore, an essential element of a healthy astromaterials curation program is a research and development (R&D) effort that characterizes and employs new technologies to maintain current collections and enable new missions - an Advanced Curation effort. JSC's Astromaterials Acquisition & Curation Office is continually performing Advanced Curation research, identifying and defining knowledge gaps about research, development, and validation/verification topics that are critical to support current and future NASA astromaterials sample collections. The following are highlighted knowledge gaps and research opportunities.

  4. A sampling system for collecting gas-tight time-series hydrothermal fluids

    NASA Astrophysics Data System (ADS)

    Wu, S.; Yang, C.; Ding, K.

    2012-12-01

    It is known that the hydrothermal venting has temporal variations associated with tectonic and geochemical processes. To date, the methods for long-term monitoring of the seafloor hydrothermal systems are rare. A new sampling system has been designed to be deployed at seafloor for long term to collect gas-tight time-series samples from hydrothermal vents. Based on the modular design principle, the sampling system is currently composed of a control module and six sampling modules, which is convenient to be upgraded by adding more sampling modules if needed. The control module consists of a rechargeable battery pack and a circuit board with functions of sampling control, temperature measurement, data storage and communication. Each sampling module has an independent sampling valve, a valve actuator and a sampling cylinder. The sampling cylinder consists of a sample chamber and an accumulator chamber. Compressed nitrogen gas is used to maintain the sample at in-situ pressure. A prototype of the sampling system has been constructed and tested. First, the instrument was tested in a high-pressure vessel at a pressure of 40 MPa. Six sampling modules were successfully triggered and water samples were collected and kept at in-situ pressure after experiment. Besides, the instrument was field tested at the shallow hydrothermal field near off Kueishantao islet (24°51'N, 121°55'E), which is located offshore of northeastern Taiwan, from May 25 to May 28, 2011. The sampling system worked at an automatic mode. Each sampling module was triggered according to the preset time. Time-series hydrothermal fluids have been collected from a shallow hydrothermal vent with a depth of 16 m. The preliminary tests indicated the success of the design and construction of the prototype of the sampling system. Currently, the sampling system is being upgraded by integration of a DC-DC power conversion and serial-to-Ethernet conversion module, so that it can utilize the continuous power supply and

  5. Specific activities of 60Co and 152Eu in samples collected from the Atomic-Bomb Dome in Hiroshima.

    PubMed

    Shizuma, K; Iwatani, K; Hashi, H; Oka, T; Morishima, H; Hoshi, M

    1992-06-01

    Neutron-induced activities 60Co and 152Eu have been measured for samples collected from the Atomic-Bomb Dome locating at 161 m from the hypocenter of the Hiroshima Bomb. Specific activities 60Co/Co and 152Eu/Eu at the time of the detonation have been determined as 10.0 +/- 1.0 Bq mg-1 (steel sample S4) and 80 +/- 9 Bq mg-1 (granite sample G1), respectively. Detailed measurements of 60Co and 152Eu activities for samples collected from various locations of the Dome show almost no directional dependence whether the sample faced to the epicenter or not, nor vertical height dependence between 17 m height and the ground level. In addition, 152Eu was not detected in the sample collected from the basement. It has been shown that the present 60Co activity value, the nearest steel one to the hypocenter, as well as other short distance data are systematically lower than the calculated values based on the neutron fluence of the DS86.

  6. Comparison of water-quality samples collected by siphon samplers and automatic samplers in Wisconsin

    USGS Publications Warehouse

    Graczyk, David J.; Robertson, Dale M.; Rose, William J.; Steur, Jeffrey J.

    2000-01-01

    In small streams, flow and water-quality concentrations often change quickly in response to meteorological events. Hydrologists, field technicians, or locally hired stream ob- servers involved in water-data collection are often unable to reach streams quickly enough to observe or measure these rapid changes. Therefore, in hydrologic studies designed to describe changes in water quality, a combination of manual and automated sampling methods have commonly been used manual methods when flow is relatively stable and automated methods when flow is rapidly changing. Auto- mated sampling, which makes use of equipment programmed to collect samples in response to changes in stage and flow of a stream, has been shown to be an effective method of sampling to describe the rapid changes in water quality (Graczyk and others, 1993). Because of the high cost of automated sampling, however, especially for studies examining a large number of sites, alternative methods have been considered for collecting samples during rapidly changing stream conditions. One such method employs the siphon sampler (fig. 1). also referred to as the "single-stage sampler." Siphon samplers are inexpensive to build (about $25- $50 per sampler), operate, and maintain, so they are cost effective to use at a large number of sites. Their ability to collect samples representing the average quality of water passing though the entire cross section of a stream, however, has not been fully demonstrated for many types of stream sites.

  7. Methods for collecting algal samples as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Porter, Stephen D.; Cuffney, Thomas F.; Gurtz, Martin E.; Meador, Michael R.

    1993-01-01

    Benthic algae (periphyton) and phytoplankton communities are characterized in the U.S. Geological Survey's National Water-Quality Assessment Program as part of an integrated physical, chemical, and biological assessment of the Nation's water quality. This multidisciplinary approach provides multiple lines of evidence for evaluating water-quality status and trends, and for refining an understanding of the factors that affect water-quality conditions locally, regionally, and nationally. Water quality can be characterized by evaluating the results of qualitative and quantitative measurements of the algal community. Qualitative periphyton samples are collected to develop of list of taxa present in the sampling reach. Quantitative periphyton samples are collected to measure algal community structure within selected habitats. These samples of benthic algal communities are collected from natural substrates, using the sampling methods that are most appropriate for the habitat conditions. Phytoplankton samples may be collected in large nonwadeable streams and rivers to meet specific program objectives. Estimates of algal biomass (chlorophyll content and ash-free dry mass) also are optional measures that may be useful for interpreting water-quality conditions. A nationally consistent approach provides guidance on site, reach, and habitat selection, as well as information on methods and equipment for qualitative and quantitative sampling. Appropriate quality-assurance and quality-control guidelines are used to maximize the ability to analyze data locally, regionally, and nationally.

  8. Sample collection of virulent and non-virulent B. anthracis and Y. pestis for bioforensics analysis

    SciTech Connect

    Hong-geller, Elizabeth; Valdez, Yolanda E; Shou, Yulin; Yoshida, Thomas M; Marrone, Babetta L; Dunbar, John

    2009-01-01

    Validated sample collection methods are needed for recovery of microbial evidence in the event of accidental or intentional release of biological agents into the environment. To address this need, we evaluated the sample recovery efficiencies of two collection methods -- swabs and wipes -- for both non-virulent and virulent strains of B. anthracis and Y. pestis from four types of non-porous surfaces: two hydrophilic surfaces, stainless steel and glass, and two hydrophobic surfaces, vinyl and plastic. Sample recovery was quantified using Real-time qPCR to assay for intact DNA signatures. We found no consistent difference in collection efficiency between swabs or wipes. Furthermore, collection efficiency was more surface-dependent for virulent strains than non-virulent strains. For the two non-virulent strains, B. anthracis Sterne and Y. pestis A1122, collection efficiency was approximately 100% and 1 %, respectively, from all four surfaces. In contrast, recovery of B. anthracis Ames spores and Y. pestis C092 from vinyl and plastic was generally lower compared to collection from glass or stainless steel, suggesting that surface hydrophobicity may playa role in the strength of pathogen adhesion. The surface-dependent collection efficiencies observed with the virulent strains may arise from strain-specific expression of capsular material or other cell surface receptors that alter cell adhesion to specific surfaces. These findings contribute to validation of standard bioforensics procedures and emphasize the importance of specific strain and surface interactions in pathogen detection.

  9. Insights into explosion dynamics at Stromboli in 2009 from ash samples collected in real-time

    NASA Astrophysics Data System (ADS)

    Taddeucci, J.; Lautze, N.; Andronico, D.; D'Auria, L.; Niemeijer, A.; Houghton, B.; Scarlato, P.

    2012-04-01

    Rapid characterization of tephra during explosive eruptions can provide valuable insights into eruptive mechanisms, also integrating other monitoring systems. Here we reveal a perspective on Stromboli's conduit processes by linking ash textures to geophysical estimates of eruption parameters of observed explosions. A three day campaign at Stromboli was undertaken by Italy's Istituto Nazionale di Geofisica e Vulcanologia (INGV) in October 2009. At this time activity was moderately intense, with an average 4 to 5, both ash-rich and ash-poor, explosions per hour at each the SW and NE vents. A total of fifteen ash samples were collected in real time. We used binocular and scanning electron microscopes to analyze the components, grain size and morphology distributions, and surface chemistry of ash particles within eight selected samples. In addition, the INGV monitoring network provided visual, thermal, and seismic information on the explosions that generated the sampled ash. In each sample, the proportion of fluidal, glassy sideromelane (as opposed to blocky, microcrystalline tachylite plus lithics), the degree of "chemical freshness" (as opposed to chemical alteration), and the average size of particles appear to correlate directly with the maximum height and the seismic amplitude of the corresponding explosion, and inversely correlate with the amount of ash erupted, as estimated by monitoring videos. These observations suggest that more violent explosions (i.e., those driven by the release of larger and more pressurized gas volumes) produce ash via the fragmentation of hotter, more fluid magma, while weaker ones mostly erupt ash-sized particles derived by the fragmentation of colder magma and incorporation of conduit wall debris. The formation of fluidal ash particles (up to Pele's hairs) requires aerodynamic deformation of a relatively low-viscosity magma, in agreement with the strong acceleration imposed upon fragmented magma clots by the rapid expansion of

  10. Meteorites and microbes: meteorite collection and ice sampling at Patriot Hills, Thiel Mountains, and South Pole, Antarctica

    NASA Astrophysics Data System (ADS)

    Sipiera, Paul P.; Hoover, Richard B.; Jerman, Gregory A.

    2000-12-01

    In 1998, the Patriot Hills area of the Ellsworth Mountains of Antarctica was selected by the Planetary Studies Foundation (PSF) of Algonquin, Illinois USA as a potential site for the collection of meteorites. The eight person expedition searched several sites in and around the Patriot Hills, but met with little success in finding meteorites. In January 2000, the PSF chose to continue its efforts in the Thiel Mountains, an area of known meteorite concentrations. The goal was to collect as many meteorites as possible by extending the previously searched blue ice areas at the Moulton Escarpment. Earlier search teams collectively recovered 36 meteorites. In the five days of fieldwork at the Moulton Escarpment, the PSF team collected 19 confirmed stone meteorites, and 2 possible achondrites. Upon return to Patriot Hills another small stone meteorite, consisting of 6 small fragments totalling 1.7 grams, was collected in the Morris Moraine where a 23 mg meteorite fragment was found in 1998. In addition, ice samples were collected at Patriot Hills, Thiel Mountains, and the South Pole. The presence of several micro-organisms has been identified in these samplings and will be evaluated as possible contaminants of Antarctic meteorites.

  11. Sample Collection of Ash and Burned Soils from the October 2007 Southern California Wildfires

    USGS Publications Warehouse

    Hoefen, Todd M.; Kokaly, Raymond F.; Martin, Deborah A.; Rochester, Carlton; Plumlee, Geoffrey S.; Mendez, Greg; Reichard, Eric G.; Fisher, Robert N.

    2009-01-01

    Between November 2 through 9, 2007 scientists from the U.S. Geological Survey (USGS) collected samples of ash and burned soils from 28 sites in six areas burned as a result of the Southern California wildfires of October 2007, including the Harris, Witch, Santiago, Ammo, Canyon, and Grass Valley Fires. The primary goal of this sampling and analysis effort was to understand how differences in ash and burned soil composition relate to vegetation type, underlying bedrock geology, burn intensity, and residential versus wildland. Sampling sites were chosen with the input of local experts from the USGS Water Resources and Biological Resources Disciplines to help understand possible effects of the fires on water supplies, ecosystems, and endangered species. The sampling was also carried out in conjunction with detailed field analysis of the spectral reflectance characteristics of the ash, so that chemical and mineralogical characteristics of the field samples could be used to help interpret data collected as part of an airborne, hyperspectral remote-sensing survey of several of the burned areas in mid-late November, 2007. This report presents an overview of the field sampling methodologies used to collect the samples, includes representative photos of the sites sampled, and summarizes important characteristics of each of the collection sites. In this report we use the term 'ash' to refer collectively to white mineral ash, which results from full combustion of vegetation and black charred organic matter from partial combustion of vegetation or other materials. These materials were found to be intermingled as a deposited residue on the soil surface following the Southern California fires of 2007.

  12. Swabs as DNA collection devices for sampling different biological materials from different substrates.

    PubMed

    Verdon, Timothy J; Mitchell, Robert J; van Oorschot, Roland A H

    2014-07-01

    Currently, there is a variety of swabs for collection of biological evidence from crime scenes, but their comparative efficiency is unknown. Here, we report the results of an investigation into the efficiency of different swab types to collect blood, saliva and touch DNA from a range of substrates. The efficiency of extracting blood and saliva from each swab type was also tested. Some swabs were significantly more effective than others for sampling biological materials from different substrates. Swabs with the highest sampling efficiency, however, often did not have the highest extraction efficiency. Observations were recorded regarding practicality of each swab in a variety of situations. Our study demonstrates that selection of sampling device impacts greatly upon successful collection and extraction of DNA. We present guidelines to assist in evaluation of swab choice. PMID:24502761

  13. Handbook: Collecting Groundwater Samples from Monitoring Wells in Frenchman Flat, CAU 98

    SciTech Connect

    Chapman, Jenny; Lyles, Brad; Cooper, Clay; Hershey, Ron; Healey, John

    2015-06-01

    CAU. The sampling plan is designed to ensure that monitoring activities occur in compliance with the UGTA Quality Assurance Plan (DOE, 2012). The sampling plan should be referenced for Quality Assurance (QA) elements and procedures governing sampling activities. The NNSS Integrated Sampling Plan specifies the groundwater monitoring that will occur in CAU 98 until the long-term monitoring program is approved in the Closure Report. The plan specifies the wells that must be monitored and categorizes them by their sampling objective with the associated analytical requirements and frequency. Possible sample collection methods and required standard operating procedures are also presented. The intent of this handbook is to augment the NNSS Integrated Sampling Plan by providing well-specific details for the sampling professional implementing the Sampling Plan in CAU 98, Frenchman Flat. This handbook includes each CAU 98 well designated for sampling in the NNSS Integrated Sampling Plan. The following information is provided in the individual well sections: 1. The purpose of sampling. 2. A physical description of the well. 3. The chemical characteristics of the formation water. 4. Recommended protocols for purging and sampling. The well-specific information has been gathered from numerous historical and current sources cited in each section, but two particularly valuable resources merit special mention. These are the USGS NNSS website (http://nevada.usgs.gov/doe_nv/ntsarea5.cfm) and the UGTA Field Operations website (https://ugta.nv.doe.gov/sites/Field%20Operations/default.aspx). 2 Land surface elevation and measuring point for water level measurements in Frenchman Flat were a focus during CAU investigations (see Appendix B, Attachment 1 in Navarro-Intera, 2014). Both websites listed above provide information on the accepted datum for each well. A summary is found on the home page for the well on the USGS website. Additional information is available through a link in the

  14. Multi-element composition of historical lichen collections and bark samples, indicators of changing atmospheric conditions

    NASA Astrophysics Data System (ADS)

    Purvis, O. W.; Chimonides, P. D. J.; Jeffries, T. E.; Jones, G. C.; Rusu, A.-M.; Read, H.

    Thirty six element signatures were compared in historical Parmelia sulcata samples from the Natural History Museum herbarium collected over the period 1797-1967 with those recorded in the same species and tree bark sampled in 2000 from Burnham Beeches, lying 40 km west of London. Nineteen elements reached highest concentrations in herbarium samples, consistent with a pollution legacy and dust contamination in the herbarium. Healthy Parmelia sampled east and down-wind of London at a farm during peak SO 2 emissions in 1967 contained highest V, Ni, Zn, Cd, Se, Ge contents, supporting derivation from fuel combustion; the same sample was previously determined as having a low δ34S and high S and N contents. Lowest V, Co, Ni, Cu, Zn, Sn, Ba, Pb, Mo, Sb, Li, B, Cs, U, Th, Ga contents were recorded in a sample with a high δ34S and low S content collected in 1887 from a remote region from Ross-shire, Scotland. Se and Cd enrichment, never-the-less suggest a transboundary pollution influence. Lichen Pb concentrations from Burnham Beeches were amongst the lowest recorded in spite of lichens being collected close to roads. Herbarium samples help interpret changes in element deposition where few data exist, in spite of dust contamination.

  15. Archival policies and collections database for the Woods Hole Science Center's marine sediment samples

    USGS Publications Warehouse

    Buczkowski, Brian J.; Kelsey, Sarah A.

    2007-01-01

    The Woods Hole Science Center of the U.S. Geological Survey (USGS) has been an active member of the Woods Hole research community, Woods Hole, Massachusetts, for over 40 years. In that time there have been many projects that involved the collection of sediment samples conducted by USGS scientists and technicians for the research and study of seabed environments and processes. These samples were collected at sea or near shore and then brought back to the Woods Hole Science Center (WHSC) for analysis. While at the center, samples are stored in ambient temperature, refrigerated and freezing conditions ranging from +2º Celsius to -18º Celsius, depending on the best mode of preparation for the study being conducted or the duration of storage planned for the samples. Recently, storage methods and available storage space have become a major concern at the WHSC. The core and sediment archive program described herein has been initiated to set standards for the management, methods, and duration of sample storage. A need has arisen to maintain organizational consistency and define storage protocol. This handbook serves as a reference and guide to all parties interested in using and accessing the WHSC's sample archive and also defines all the steps necessary to construct and maintain an organized collection of geological samples. It answers many questions as to the way in which the archive functions.

  16. Pesticide content in drinking water samples collected from orchard areas in central Poland.

    PubMed

    Badach, Hanna; Nazimek, Teresa; Kamińska, Iwona A

    2007-01-01

    Samples of drinking water collected in Warka-Grójec region of central Poland were tested for the presence of pesticides. Data obtained from analysis of water samples will be used for future epidemiological and environmental studies in the region. Samples were collected during spring and autumn of 2002-2003 from dug wells, deep wells and water mains in 81 randomly-selected rural households scattered throughout this region of extensive agriculture. The concentration of pesticides from four main chemical groups was determined by gas chromatography: organochlorines (lindane, DDT, methoxychlor), triazines (atrazine, simazine), organophosphates (acephate, diazinon, fenitrothion) and pyrethroids (alpha-cypermethrin, deltamethrin). Two-year monitoring of drinking water samples indicated the presence of DDT and methoxychlor contamination. Pyrethroids were generally not detected, with the exception of alpha-cypermethrin found in only a few samples. Triazines were also found in water samples collected in the course of the study with higher incidence during spring period. Organophosphates were by far the most common contaminants of drinking water in this region. Almost all samples were contaminated by significant amounts of fenitrothion. The present study reveals an urgent need for systematic monitoring of drinking water quality in regions of intensive agriculture, since they are highly vulnerable to pesticide contamination. Consumption of pesticide-contaminated water may have a negative impact on the population living in this area, which also requires scientific assessment.

  17. Study Design and Percent Recoveries of Anthropogenic Organic Compounds With and Without the Addition of Ascorbic Acid to Preserve Water Samples Containing Free Chlorine, 2004-06

    USGS Publications Warehouse

    Valder, Joshua F.; Delzer, Gregory C.; Price, Curtis V.; Sandstrom, Mark W.

    2008-01-01

    The National Water-Quality Assessment (NAWQA) Program of the U.S. Geological Survey (USGS) began implementing Source Water-Quality Assessments (SWQAs) in 2002 that focus on characterizing the quality of source water and finished water of aquifers and major rivers used by some of the larger community water systems in the United States. As used for SWQA studies, source water is the raw (ambient) water collected at the supply well prior to water treatment (for ground water) or the raw (ambient) water collected from the river near the intake (for surface water). Finished water is the water that is treated, which typically involves, in part, the addition of chlorine or other disinfection chemicals to remove pathogens, and is ready to be delivered to consumers. Finished water is collected before the water enters the distribution system. This report describes the study design and percent recoveries of anthropogenic organic compounds (AOCs) with and without the addition of ascorbic acid to preserve water samples containing free chlorine. The percent recoveries were determined by using analytical results from a laboratory study conducted in 2004 by the USGS's National Water Quality Laboratory (NWQL) and from data collected during 2004-06 for a field study currently (2008) being conducted by the USGS's NAWQA Program. The laboratory study was designed to determine if preserving samples with ascorbic acid (quenching samples) adversely affects analytical performance under controlled conditions. During the laboratory study, eight samples of reagent water were spiked for each of five analytical schedules evaluated. Percent recoveries from these samples were then compared in two ways: (1) four quenched reagent spiked samples analyzed on day 0 were compared with four quenched reagent spiked samples analyzed on day 7 or 14, and (2) the combined eight quenched reagent spiked samples analyzed on day 0, 7, or 14 were compared with eight laboratory reagent spikes (LRSs). Percent

  18. Methods for collection and analysis of aquatic biological and microbiological samples

    USGS Publications Warehouse

    Greeson, Phillip E., (Edited By); Ehlke, T.A.; Irwin, G.A.; Lium, B.W.; Slack, K.V.

    1977-01-01

    Chapter A4 contains methods used by the U.S. Geological Survey to collect, preserve, and analyze waters to determine their biological and microbiological properties. Part 1 discusses biological sampling and sampling statistics. The statistical procedures are accompanied by examples. Part 2 consists of detailed descriptions of more than 45 individual methods, including those for bacteria, phytoplankton, zooplankton, seston, periphyton, macrophytes, benthic invertebrates, fish and other vertebrates, cellular contents, productivity, and bioassays. Each method is summarized, and the application, interferences, apparatus, reagents, collection, analysis, calculations, reporting of results, precision and references are given. Part 3 consists of a glossary. Part 4 is a list of taxonomic references.

  19. Sample collection and preparation of biofluids and extracts for gas chromatography-mass spectrometry.

    PubMed

    Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Kharbatia, Najeh M

    2015-01-01

    To maximize the utility of gas chromatography-mass spectrometry (GC-MS) in metabonomics research, all stages of the experimental design should be standardized, including sample collection, storage, preparation, and sample separation. Moreover, the prerequisite for any GC-MS analysis is that a compound must be volatile and thermally stable if it is to be analyzed using this technique. Since many metabolites are nonvolatile and polar in nature, they are not readily amenable to analysis by GC-MS and require initial chemical derivatization of the polar functional groups in order to reduce the polarity and to increase the thermal stability and volatility of the analytes. In this chapter, an overview is presented of the optimum approach to sample collection, storage, and preparation for gas chromatography-mass spectrometry-based metabonomics with particular focus on urine samples as example of biofluids.

  20. An unmanned mission to Mars with sample collection and in-situ resource utilization

    NASA Astrophysics Data System (ADS)

    1994-05-01

    The design for the Mars Analysis and Return Vehicle with In-Situ Resource Utilization (MARVIN) project is outlined. The MARVIN mission is designed to collect samples of the Martian environment; to produce fuel from local Martian resources; and to use the fuel produced to return the samples to earth. It uses only existing technologies. Exploratory Technologies' mission-design efforts have focused on methods of orbit determination, sample collection, fuel production, power, communications, control, and structural design. Lambert Targeting provided Delta-V's, launch dates, and travel times. The landing site is the Tharsis Plateau, to the southeast of Olympus Mons, chosen for its substantial scientific value. Samples of soil, dust, and atmosphere are collected with lander-based collection devices: the soil sample, with a robotic arm similar to those used in the Viking missions; the atmospheric sample, from a bleed line to the compressor in the fuel-production facility; a dust sample, from the dust-collection container in the fuel-production facility; and a redundant dust sample, with a with a passive filter system, which relies upon neither a power source nor other collection methods. The sample-return capsule (SRC) houses these samples, which are triply contained to prevent contamination. Proven technology can be used to produce methane and oxygen for fuel with relative ease at the landing site: the Sabatier reactor produces methane and water by combining carbon dioxide and hydrogen (brought from earth); the Reverse Water-Gas Shift unit combines carbon dioxide and hydrogen to form carbon monoxide and water; a water-electrolysis unit splits the water into hydrogen and oxygen. The Mars-lander vehicle (MLV) transports the equipment from earth to Mars. The Mars-ascent vehicle (MAV) contains the SRC and the engine, which is the same for both the MLV and the MAV. All equipment that is unnecessary for the Mars-Earth trajectory remains on Mars. This report presents detailed

  1. An unmanned mission to Mars with sample collection and in-situ resource utilization

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The design for the Mars Analysis and Return Vehicle with In-Situ Resource Utilization (MARVIN) project is outlined. The MARVIN mission is designed to collect samples of the Martian environment; to produce fuel from local Martian resources; and to use the fuel produced to return the samples to earth. It uses only existing technologies. Exploratory Technologies' mission-design efforts have focused on methods of orbit determination, sample collection, fuel production, power, communications, control, and structural design. Lambert Targeting provided Delta-V's, launch dates, and travel times. The landing site is the Tharsis Plateau, to the southeast of Olympus Mons, chosen for its substantial scientific value. Samples of soil, dust, and atmosphere are collected with lander-based collection devices: the soil sample, with a robotic arm similar to those used in the Viking missions; the atmospheric sample, from a bleed line to the compressor in the fuel-production facility; a dust sample, from the dust-collection container in the fuel-production facility; and a redundant dust sample, with a with a passive filter system, which relies upon neither a power source nor other collection methods. The sample-return capsule (SRC) houses these samples, which are triply contained to prevent contamination. Proven technology can be used to produce methane and oxygen for fuel with relative ease at the landing site: the Sabatier reactor produces methane and water by combining carbon dioxide and hydrogen (brought from earth); the Reverse Water-Gas Shift unit combines carbon dioxide and hydrogen to form carbon monoxide and water; a water-electrolysis unit splits the water into hydrogen and oxygen. The Mars-lander vehicle (MLV) transports the equipment from earth to Mars. The Mars-ascent vehicle (MAV) contains the SRC and the engine, which is the same for both the MLV and the MAV. All equipment that is unnecessary for the Mars-Earth trajectory remains on Mars. This report presents detailed

  2. Field Methods and Sample Collection Techniques for the Surveillance of West Nile Virus in Avian Hosts.

    PubMed

    Wheeler, Sarah S; Boyce, Walter M; Reisen, William K

    2016-01-01

    Avian hosts play an important role in the spread, maintenance, and amplification of West Nile virus (WNV). Avian susceptibility to WNV varies from species to species thus surveillance efforts can focus both on birds that survive infection and those that succumb. Here we describe methods for the collection and sampling of live birds for WNV antibodies or viremia, and methods for the sampling of dead birds. Target species and study design considerations are discussed. PMID:27188560

  3. Sample collection and platelet function testing: influence of vacuum or aspiration principle on PFA-100 test results.

    PubMed

    Lippi, Giuseppe; Ippolito, Luigi; Zobbi, Valentina; Sandei, Franca; Favaloro, Emmanuel J

    2013-09-01

    As for other tests of hemostasis, the investigation of platelet function is highly vulnerable to a broad series of preanalytical variables, which span from patient preparation to the final analysis of the specimen and issuance of test results. In particular, there remains much controversy about the influence of manual or vacuum aspiration of blood into primary collection tubes on platelet function testing. Accordingly, we investigated this for the PFA-100. In 12 healthy volunteers, a sample labeled as 'BD-V' was drawn into a 2.7 ml BD Vacutainer tube, whereas two additional samples were collected from the opposite arm into 5.0 ml Sarstedt S-Monovette tubes by vacuum (SD-V) or manual aspiration (SD-A). All sample were tested on PFA-100 with collagen and ADP (CADP) or collagen and epinephrine (CEPI). The values of both CEPI and CADP obtained in SD-A samples were significantly lower than those obtained in SD-V and BD-V tubes, whereas those of the two evacuated tubes did not significantly differ. On average, CEPI values were prolonged by 11% in SD-V and 13% in BD-V, whereas those of CADP were prolonged by 14% in SD-V and 10% in BD-V, respectively. These findings suggests that the lower shear stress generated by the manual aspiration of blood into the primary collection tube would prevent spurious hyper-activation of platelets, thus, preserving the integrity of their function for subsequent testing on PFA-100. This study underscores the need to define or validate local reference ranges for the PFA-100 based on the collection tube used. Different reference ranges of both CEPI and CADP may also be advisable when venous blood samples are collected with manual aspiration or vacuum principle.

  4. 21 CFR 809.40 - Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... OTC test sample collection systems for drugs of abuse testing. 809.40 Section 809.40 Food and Drugs... Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs of abuse testing. (a) Over-the-counter (OTC) test sample collection systems for drugs of abuse testing (§...

  5. 21 CFR 809.40 - Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... OTC test sample collection systems for drugs of abuse testing. 809.40 Section 809.40 Food and Drugs... Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs of abuse testing. (a) Over-the-counter (OTC) test sample collection systems for drugs of abuse testing (§...

  6. Field guidelines for collection, treatment, and analysis of water samples, Montana district

    USGS Publications Warehouse

    Knapton, J.R.

    1985-01-01

    This manual provides a set of standardized guidelines and quality-control procedures for the collection and preservation of water samples and defines procedures for field analyses of unstable constituents or properties. Seldom is the water being samples of such uniformity that a single grab sample is representative of the whole. For this reason a variety of sampler types and sampling methods have been devised. Descriptions and procedures for field use are given for a number of sampler types. Several methods of sampling are described for which these samplers can be used. Sample-processing devices such as sample splitters and filtration apparatus are discussed along with methods of cleaning. Depending on the type of analysis to be performed in the laboratory, samples may need to be preserved shortly after collection. Various types of preservation are described in detail. Analyses for unstable constituents or properties are of necessity accomplished in the field. This manual addresses analytical techniques and quality assurance for: (1) Water temperature, (2) specific conductance, (3) pH, (4) alkalinity, (5) dissolved oxygen, and (6) bacteria. Examples of field report forms are given as attachments. Information pertinent to certain field calculations is also presented. (USGS)

  7. Flue gas conditioning for improved particle collection in electrostatic precipitators. First topical report, Results of laboratory screening of additives

    SciTech Connect

    Durham, M.D.

    1993-04-16

    Several tasks have been completed in a program to evaluate additives to improve fine particle collection in electrostatic precipitators. Screening tests and laboratory evaluations of additives are summarized in this report. Over 20 additives were evaluated; four were found to improve flyash precipitation rates. The Insitec particle analyzer was also evaluated; test results show that the analyzer will provide accurate sizing and counting information for particles in the size range of {le} 10 {mu}m dia.

  8. Curating NASA's future extraterrestrial sample collections: How do we achieve maximum proficiency?

    NASA Astrophysics Data System (ADS)

    McCubbin, Francis; Evans, Cynthia; Allton, Judith; Fries, Marc; Righter, Kevin; Zolensky, Michael; Zeigler, Ryan

    2016-07-01

    Introduction: The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10E "Curation of Extraterrestrial Materials", JSC is charged with "The curation of all extraterrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "…documentation, preservation, preparation, and distribution of samples for research, education, and public outreach." Here we describe some of the ongoing efforts to ensure that the future activities of the NASA Curation Office are working to-wards a state of maximum proficiency. Founding Principle: Curatorial activities began at JSC (Manned Spacecraft Center before 1973) as soon as design and construction planning for the Lunar Receiving Laboratory (LRL) began in 1964 [1], not with the return of the Apollo samples in 1969, nor with the completion of the LRL in 1967. This practice has since proven that curation begins as soon as a sample return mission is conceived, and this founding principle continues to return dividends today [e.g., 2]. The Next Decade: Part of the curation process is planning for the future, and we refer to these planning efforts as "advanced curation" [3]. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of collections as envisioned by NASA exploration goals. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, curation of organically- and biologically-sensitive samples, and the use of minimally invasive analytical techniques (e.g., micro-CT, [4]) to characterize samples. These efforts will be useful for Mars Sample Return

  9. Starting a European Space Agency Sample Analogue Collection for Robotic Exploration Missions

    NASA Astrophysics Data System (ADS)

    Smith, C. L.; Mavris, C.; Michalski, J. R.; Rumsey, M. S.; Russell, S. S.; Jones, C.; Schroeven-Deceuninck, H.

    2015-12-01

    The Natural History Museum is working closely with the European Space Agency (ESA) and the UK Space Agency to develop a European collection of analogue materials with appropriate physical/mechanical and chemical (mineralogical) properties which can support the development and verification of both spacecraft and scientific systems for potential science and exploration missions to Phobos/Deimos, Mars, C-type asteroids and the Moon. As an ESA Collection it will be housed at the ESA Centre based at Harwell, UK. The "ESA Sample Analogues Collection" will be composed of both natural and artificial materials chosen to (as closely as possible) replicate the surfaces and near-surfaces of different Solar System target bodies of exploration interest. The analogue samples will be fully characterised in terms of both their physical/mechanical properties (compressive strength, bulk density, grain shape, grain size, cohesion and angle of internal friction) and their chemical/mineralogical properties (texture, modal mineralogy, bulk chemical composition - major, minor and trace elements and individual mineralogical compositions). The Collection will be fully curated to international standards including implementation of a user-friendly database and will be available for use by engineers and scientists across the UK and Europe. Enhancement of the initial Collection will be possible through collaborations with other ESA and UK Space Agency supported activities, such as the acquisition of new samples during field trials.

  10. Starting a European Space Agency Sample Analogue Collection for Robotic Exploration Missions

    NASA Astrophysics Data System (ADS)

    Sherwood Lollar, B.; Sutcliffe, C. N.; Ballentine, C. J.; Onstott, T. C.; Lau, C. Y. M.; Magnabosco, C.; Slater, G.; Moser, D. P.

    2014-12-01

    The Natural History Museum is working closely with the European Space Agency (ESA) and the UK Space Agency to develop a European collection of analogue materials with appropriate physical/mechanical and chemical (mineralogical) properties which can support the development and verification of both spacecraft and scientific systems for potential science and exploration missions to Phobos/Deimos, Mars, C-type asteroids and the Moon. As an ESA Collection it will be housed at the ESA Centre based at Harwell, UK. The "ESA Sample Analogues Collection" will be composed of both natural and artificial materials chosen to (as closely as possible) replicate the surfaces and near-surfaces of different Solar System target bodies of exploration interest. The analogue samples will be fully characterised in terms of both their physical/mechanical properties (compressive strength, bulk density, grain shape, grain size, cohesion and angle of internal friction) and their chemical/mineralogical properties (texture, modal mineralogy, bulk chemical composition - major, minor and trace elements and individual mineralogical compositions). The Collection will be fully curated to international standards including implementation of a user-friendly database and will be available for use by engineers and scientists across the UK and Europe. Enhancement of the initial Collection will be possible through collaborations with other ESA and UK Space Agency supported activities, such as the acquisition of new samples during field trials.

  11. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false OTC test sample collection systems for drugs of abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES...

  12. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false OTC test sample collection systems for drugs of abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES...

  13. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false OTC test sample collection systems for drugs of abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES...

  14. 7 CFR 52.44 - Inspection fees when charges for sampling have been collected.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946 AND THE EGG PRODUCTS INSPECTION ACT PROCESSED FRUITS AND VEGETABLES, PROCESSED PRODUCTS THEREOF, AND CERTAIN OTHER PROCESSED FOOD PRODUCTS 1 Regulations... have been collected. For any lot of processed products from which a sample in drawn by a...

  15. 7 CFR 52.44 - Inspection fees when charges for sampling have been collected.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946 AND THE EGG PRODUCTS INSPECTION ACT PROCESSED FRUITS AND VEGETABLES, PROCESSED PRODUCTS THEREOF, AND CERTAIN OTHER PROCESSED FOOD PRODUCTS 1 Regulations... have been collected. For any lot of processed products from which a sample in drawn by a...

  16. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN USING GAUZE FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure, urine samples are often needed to analyze pesticide metabolites. However, this is difficult for children wearing diapers because simple and feasible techniques suitable for field collection are not available. The objectives of this study were to te...

  17. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN USING COTTON GAUZE FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure, urine samples are often needed to analyze pesticide metabolites. However, this is difficult for children wearing diapers because simple and feasible techniques suitable for field collection are not available. The objectives of this study were to t...

  18. Collecting Stream Samples for Water Quality. Module 16. Vocational Education Training in Environmental Health Sciences.

    ERIC Educational Resources Information Center

    Consumer Dynamics Inc., Rockville, MD.

    This module, one of 25 on vocational education training for careers in environmental health occupations, contains self-instructional materials on collecting stream samples for water quality. Following guidelines for students and instructors and an introduction that explains what the student will learn are three lessons: (1) using a job aid to…

  19. 78 FR 25308 - Proposed Collection; Comment Request; Coal Mine Dust Sampling Devices

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-30

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF LABOR Mine Safety and Health Administration Proposed Collection; Comment Request; Coal Mine Dust Sampling Devices AGENCY: Mine Safety and Health Administration, Labor. ACTION: 60-Day Notice. SUMMARY: The Department...

  20. 9 CFR 147.12 - Procedures for collection, isolation, and identification of Salmonella from environmental samples...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., litter, dust, or floor litter surface or nest box drag swab samples to be submitted for bacteriological... common; e.g., on or near waterers, feeders, nests, or rafters, etc. When the volume of material collected... the surface of random, flock-representative floor litter and nest box areas. The sampler pads shall...

  1. College Students' Perceptions of Collective Efficacy: Results from a Nonurban Sample

    ERIC Educational Resources Information Center

    Domoff, Sarah E.; Hayman, Jennifer; Tompsett, Carolyn J.

    2012-01-01

    Although the relationship between neighborhood characteristics and collective efficacy is well established in urban populations with community samples, it is unclear if this relationship holds in rural areas. The current study fills this gap by assessing the perceptions of adolescents from nonurban areas to examine the relationships between…

  2. Gene banking: A quality control perspective on collection, and analysis of samples for a national repository

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The National Animal Germplasm Program (NAGP) is developing a national repository for germplasm (semen, oocytes, embryos, blood, DNA, tissue) for all agricultural species in the United States. Currently, the swine collection consists of 127,479 samples from 886 boars representing 20 major, minor and...

  3. Astronauts Young and Duke collect rock samples along simulated lunar traverse

    NASA Technical Reports Server (NTRS)

    1971-01-01

    Astronauts John W. Young, left, prime crew commander for Apollo 16, and Charles M. Duke Jr., lunar module pilot, collect rock samples along a simulated lunar traverse route in the Coso Hills, near Ridgecrest, California. Astronaut Eugene A. Cernan, right background, prime crew commander for Apollo 17, looks on. The astronauts trained at the U.S. Naval Ordnance Test Station.

  4. Method for rapid screening analysis of Sr-90 in edible plant samples collected near Fukushima, Japan.

    PubMed

    Amano, Hikaru; Sakamoto, Hideaki; Shiga, Norikatsu; Suzuki, Kaori

    2016-06-01

    A screening method for measuring (90)Sr in edible plant samples by focusing on (90)Y in equilibrium with (90)Sr is reported. (90)Y was extracted from samples with acid, co-precipitated with iron hydroxide, and precipitated with oxalic acid. The dissolved oxalate precipitate was loaded on an extraction chromatography resin, and the (90)Y-enriched eluate was analyzed by Cherenkov counting with a TDCR liquid scintillation counter. (90)Sr ((90)Y) concentration was determined in plant samples collected near the damaged Fukushima Daiichi Nuclear Power Plants with this method. PMID:27043171

  5. Implementing Self-collection of Biological Specimens With a Diverse Sample

    PubMed Central

    Fernandes, April; Skinner, Martie L.; Woelfel, Tiffany; Carpenter, Thomas; Haggerty, Kevin P.

    2013-01-01

    Collecting saliva is the most noninvasive way to detect changing levels of cortisol (Adam & Kumari, 2009; Soo-Quee Koh & Choon-Huat Koh, 2007), a stress hormone of interest to behavioral and health scientists, where there are benefits from multiple samples taken over a period of days. Various self-collection strategies have been employed, ranging from treated cards to cotton swabs and passive drool methods. The current study investigates the effectiveness of a variety of reminder techniques in encouraging adherence with procedures requiring 4 samples per day on 3 separate days of passive drool collection among African American and European American young adults. The findings suggest that direct texts were associated with the greatest level of adherence, while phone reminders were most effective when controlling for total number of contacts. Results indicate that both traditional and novel reminder methods can positively influence adherence, even with challenging populations. PMID:24376374

  6. 19 CFR 151.11 - Request for samples or additional examination packages after release of merchandise.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING... of this chapter. For purposes of determining admissibility, representatives of the Food and Drug Administration may obtain samples of any food, drug, device, or cosmetic, the importation of which is governed...

  7. 19 CFR 151.11 - Request for samples or additional examination packages after release of merchandise.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING... of this chapter. For purposes of determining admissibility, representatives of the Food and Drug Administration may obtain samples of any food, drug, device, or cosmetic, the importation of which is governed...

  8. 19 CFR 151.11 - Request for samples or additional examination packages after release of merchandise.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING... of this chapter. For purposes of determining admissibility, representatives of the Food and Drug Administration may obtain samples of any food, drug, device, or cosmetic, the importation of which is governed...

  9. 19 CFR 151.11 - Request for samples or additional examination packages after release of merchandise.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING... of this chapter. For purposes of determining admissibility, representatives of the Food and Drug Administration may obtain samples of any food, drug, device, or cosmetic, the importation of which is governed...

  10. New additions to the National Plant Germplasm System’s Beta collection: Southern Morocco expedition

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The USDA Agricultural Research Service’s National Plant Germplasm System’s (NPGS) Beta collection is comprised of 2,541 accessions from 14 species. The largest number of accessions is from Beta vulgaris ssp. vulgaris, (domesticated beet crops – table, leaf (Swiss chard), fodder and, primarily, sugar...

  11. 78 FR 22937 - 60-Day Notice of Proposed Information Collection: Application for Additional Visa Pages or...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-17

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF STATE 60-Day... Passport Services ACTION: Notice of request for public comment. SUMMARY: The Department of State is seeking Office of Management and ] Budget (OMB) approval for the information collection described below....

  12. Toward Lower Organic Environments in Astromaterial Sample Curation for Diverse Collections

    NASA Technical Reports Server (NTRS)

    Allton, J. H.; Allen, C. C.; Burkett, P. J.; Calaway, M. J.; Oehler, D. Z.

    2012-01-01

    Great interest was taken during the frenzied pace of the Apollo lunar sample return to achieve and monitor organic cleanliness. Yet, the first mission resulted in higher organic contamination to samples than desired. But improvements were accomplished by Apollo 12 [1]. Quarantine complicated the goal of achieving organic cleanliness by requiring negative pressure glovebox containment environments, proximity of animal, plant and microbial organic sources, and use of organic sterilants in protocols. A special low organic laboratory was set up at University of California Berkeley (UCB) to cleanly subdivide a subset of samples [2, 3, 4]. Nevertheless, the basic approach of handling rocks and regolith inside of a positive pressure stainless steel glovebox and restrict-ing the tool and container materials allowed in the gloveboxes was established by the last Apollo sample re-turn. In the last 40 years, the collections have grown to encompass Antarctic meteorites, Cosmic Dust, Genesis solar wind, Stardust comet grains and Hayabusa asteroid grains. Each of these collections have unique curation requirements for organic contamination monitor-ing and control. Here is described some changes allowed by improved technology or driven by changes in environmental regulations and economy, concluding with comments on organic witness wafers. Future sample return missions (OSIRIS-Rex; Mars; comets) will require extremely low levels of organic contamination in spacecraft collection and thus similarly low levels in curation. JSC Curation is undertaking a program to document organic baseline levels in current operations and devise ways to reduce those levels.

  13. Modeling and enhanced sampling of molecular systems with smooth and nonlinear data-driven collective variables

    NASA Astrophysics Data System (ADS)

    Hashemian, Behrooz; Millán, Daniel; Arroyo, Marino

    2013-12-01

    Collective variables (CVs) are low-dimensional representations of the state of a complex system, which help us rationalize molecular conformations and sample free energy landscapes with molecular dynamics simulations. Given their importance, there is need for systematic methods that effectively identify CVs for complex systems. In recent years, nonlinear manifold learning has shown its ability to automatically characterize molecular collective behavior. Unfortunately, these methods fail to provide a differentiable function mapping high-dimensional configurations to their low-dimensional representation, as required in enhanced sampling methods. We introduce a methodology that, starting from an ensemble representative of molecular flexibility, builds smooth and nonlinear data-driven collective variables (SandCV) from the output of nonlinear manifold learning algorithms. We demonstrate the method with a standard benchmark molecule, alanine dipeptide, and show how it can be non-intrusively combined with off-the-shelf enhanced sampling methods, here the adaptive biasing force method. We illustrate how enhanced sampling simulations with SandCV can explore regions that were poorly sampled in the original molecular ensemble. We further explore the transferability of SandCV from a simpler system, alanine dipeptide in vacuum, to a more complex system, alanine dipeptide in explicit water.

  14. PIXE Analysis of Aerosol and Soil Samples Collected in the Adirondack Mountains

    NASA Astrophysics Data System (ADS)

    Yoskowitz, Joshua; Ali, Salina; Nadareski, Benjamin; Labrake, Scott; Vineyard, Michael

    2014-09-01

    We have performed an elemental analysis of aerosol and soil samples collected at Piseco Lake in Upstate New York using proton induced X-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the aerosol samples near Piseco Lake and distribute the particulate matter onto Kapton foils by particle size. The soil samples were also collected at Piseco Lake and pressed into cylindrical pellets for experimentation. PIXE analysis of the aerosol and soil samples were performed with 2.2-MeV proton beams from the 1.1-MV Pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. There are higher concentrations of sulfur at smaller particle sizes (0.25-1 μm), suggesting that it could be suspended in the air for days and originate from sources very far away. Other elements with significant concentrations peak at larger particle sizes (1-4 μm) and are found in the soil samples, suggesting that these elements could originate in the soil. The PIXE analysis will be described and the resulting data will be presented.

  15. Modeling and enhanced sampling of molecular systems with smooth and nonlinear data-driven collective variables.

    PubMed

    Hashemian, Behrooz; Millán, Daniel; Arroyo, Marino

    2013-12-01

    Collective variables (CVs) are low-dimensional representations of the state of a complex system, which help us rationalize molecular conformations and sample free energy landscapes with molecular dynamics simulations. Given their importance, there is need for systematic methods that effectively identify CVs for complex systems. In recent years, nonlinear manifold learning has shown its ability to automatically characterize molecular collective behavior. Unfortunately, these methods fail to provide a differentiable function mapping high-dimensional configurations to their low-dimensional representation, as required in enhanced sampling methods. We introduce a methodology that, starting from an ensemble representative of molecular flexibility, builds smooth and nonlinear data-driven collective variables (SandCV) from the output of nonlinear manifold learning algorithms. We demonstrate the method with a standard benchmark molecule, alanine dipeptide, and show how it can be non-intrusively combined with off-the-shelf enhanced sampling methods, here the adaptive biasing force method. We illustrate how enhanced sampling simulations with SandCV can explore regions that were poorly sampled in the original molecular ensemble. We further explore the transferability of SandCV from a simpler system, alanine dipeptide in vacuum, to a more complex system, alanine dipeptide in explicit water. PMID:24320358

  16. Atmospheric CO{sub 2} concentrations derived from flask samples collected at USSR-operated sampling sites

    SciTech Connect

    Boden, T.A.; Brounshtein, A.M.; Faber, E.V.; Shashkov, A.A.

    1991-12-01

    This document presents daily atmospheric CO{sub 2} concentrations from four USSR-operated sampling sites (Teriberka Station, Ocean Station Charlie, Bering Island, and Kotelny Island). The period of record varies by station with the earliest measurements dating back to 1983 and recent estimates from early 1991. These CO{sub 2} concentrations are derived from air samples collected in 1.5-L stainless steel electropolished flasks and later analyzed at the Main Geophysical Observatory (St. Petersburg, USSR) using a nondispersive infrared gas analyzer. Measurements not meeting wind direction, wind speed, inter-flask agreement, and climate condition criteria were either discarded or flagged. All measurements have been corrected for drift biases introduced during flask storage. These atmospheric CO{sub 2} concentrations are considered indicative of regional background air conditions and are directly traceable to the World Meteorological Organization`s primary CO{sub 2} standards. These measurements support the rising trend in atmospheric CO{sub 2} concentrations measured at other monitoring sites around the world and may be compared with similar measurements made by various monitoring programs at other northern latitude sites. The document presents the atmospheric CO{sub 2} concentrations in graphical and tabular form, describes the sampling methods, defines limitations and restrictions of the data, and describes the information on the magnetic media.

  17. Comparison of blood chemistry values for samples collected from juvenile chinook salmon by three methods

    USGS Publications Warehouse

    Congleton, J.L.; LaVoie, W.J.

    2001-01-01

    Thirteen blood chemistry indices were compared for samples collected by three commonly used methods: caudal transection, heart puncture, and caudal vessel puncture. Apparent biases in blood chemistry values for samples obtained by caudal transection were consistent with dilution with tissue fluids: alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), creatine kinase (CK), triglyceride, and K+ were increased and Na+ and Cl- were decreased relative to values for samples obtained by caudal vessel puncture. Some enzyme activities (ALT, AST, LDH) and K+ concentrations were also greater in samples taken by heart puncture than in samples taken by caudal vessel puncture. Of the methods tested, caudal vessel puncture had the least effect on blood chemistry values and should be preferred for blood chemistry studies on juvenile salmonids.

  18. Determination of multiple toxins in whelk and clam samples collected from the Chukchi and Bering seas.

    PubMed

    Li, Aifeng; Chen, Huidan; Qiu, Jiangbing; Lin, Heshan; Gu, Haifeng

    2016-01-01

    Buccinidae whelk Neptunea varicifera (Dall), Cardiidae clam Serripes laperousii (Deshayes), and two unknown species of whelk and clam were collected from the Arctic Chukchi Sea and sub-Arctic Bering Sea in July 2014. In this study, the mollusk samples were analyzed by different liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS) methods for multiple shellfish toxins, including okadaic acid (OA), pectenotoxin (PTX), yessotoxin (YTX), azaspiracid (AZA), cyclic imines (CI), and saxitoxin (STX) groups. PTX2 (≈2.0 μg kg(-1) whole tissues) was detected exclusively in the clam S. laperousii collected from the Chukchi Sea. OA and dinophysistoxin-1 (DTX1) were restricted to mollusk samples collected from the Bering Sea, and OA was the dominant component of the whelk N. varicifera (63 μg kg(-1) digestive gland) and an unknown species of whelk (6.8 μg kg(-1) digestive gland). Spirolide-1 (SPX1) was confirmed in most samples except for the whelk N. varicifera collected from the Bering Sea. The highest content of SPX1 (≈18.5 μg kg(-1) digestive gland) occurred in the whelk N. varicifera collected from the Chukchi Sea, along with the suspected presence of SPX-C, SPX-D and didesMe-SPX-C. YTX, as well as its derivatives 45-OH-YTX and 45,46,47-Trinor-YTX, were found in all samples, with the highest YTX content (66 μg kg(-1) digestive gland) present in the whelk N. varicifera collected from the Chukchi Sea. Interestingly, STX and dcSTX were measured only in the whelk N. varicifera and unknown species of clam collected from the Chukchi Sea. No AZA-group toxins, gymnodimine (GYM), or pinnatoxin G were found in any samples analyzed. Results demonstrated that the mollusk samples were contaminated by multiple shellfish toxins in the Chukchi and Bering seas. This study highlights the need to monitor potentially toxic microalgae in the Arctic and sub-Arctic regions, as well as species of mollusk that may be included in future commercial or

  19. Optimizing detection of noble gas emission at a former UNE site: sample strategy, collection, and analysis

    NASA Astrophysics Data System (ADS)

    Kirkham, R.; Olsen, K.; Hayes, J. C.; Emer, D. F.

    2013-12-01

    Underground nuclear tests may be first detected by seismic or air samplers operated by the CTBTO (Comprehensive Nuclear-Test-Ban Treaty Organization). After initial detection of a suspicious event, member nations may call for an On-Site Inspection (OSI) that in part, will sample for localized releases of radioactive noble gases and particles. Although much of the commercially available equipment and methods used for surface and subsurface environmental sampling of gases can be used for an OSI scenario, on-site sampling conditions, required sampling volumes and establishment of background concentrations of noble gases require development of specialized methodologies. To facilitate development of sampling equipment and methodologies that address OSI sampling volume and detection objectives, and to collect information required for model development, a field test site was created at a former underground nuclear explosion site located in welded volcanic tuff. A mixture of SF-6, Xe127 and Ar37 was metered into 4400 m3 of air as it was injected into the top region of the UNE cavity. These tracers were expected to move towards the surface primarily in response to barometric pumping or through delayed cavity pressurization (accelerated transport to minimize source decay time). Sampling approaches compared during the field exercise included sampling at the soil surface, inside surface fractures, and at soil vapor extraction points at depths down to 2 m. Effectiveness of various sampling approaches and the results of tracer gas measurements will be presented.

  20. Transient thermal envelope for rovers and sample collecting devices on the Moon

    NASA Astrophysics Data System (ADS)

    Hager, P. B.; Parzinger, S.; Haarmann, R.; Walter, U.

    2015-03-01

    The requirements for the design of rovers and sample collecting devices for the Moon are driven by the harsh and diverse thermal lunar environment. Local lunar surface temperatures are governed by boulders and craters. The present work quantifies the changes in solar and infrared heat fluxes q˙Sol and q˙IR impinging on a rover or a sample collecting device, on the surface of the Moon, by combining lunar surface models, spacecraft and manipulator models, and transient thermal calculations. The interaction between a rover, boulders, and craters was simulated for three solar elevation angles (θ = 2°, 10°, and 90°), resembling lunar surface temperatures of Treg = 170, 248, and 392 K, respectively. Infrared and solar heat fluxes for paths in the vicinity of a single boulder, a field of five boulders, and a single crater were compared to a path on an unobstructed surface. The same heat fluxes were applied to closed and open sample collecting devices to investigate the temperature development of the transported regolith sample. The results show how total received infrared heat on a rover may increase by up to 331%, over the course of a transit in front of sunlit boulders compared to the same transit over an unobstructed plane. Temporary this leads to a 12-fold increased infrared heat flux at closest distance to the obstacle. A transit through a small bowl shaped crater on the other hand may decrease total received solar heat by as much as 86%. Relative as well as absolute influence of surface features on received heat fluxes increases significantly towards smaller solar elevation angles. The temperature of pristine samples, transported in closed or open sample collecting devices, increase from 120 to 150 K within 1 to 1.3 h if exposed to direct solar illumination and infrared heat. Protection from solar illumination yields in 8-fold and 5-fold increased transport times for closed and open sample devices, respectively. Closed sample transporters dampen short exposure

  1. Macroinvertebrate and algal community sample collection methods and data collected at selected sites in the Eagle River watershed, Colorado, 2000-07

    USGS Publications Warehouse

    Zuellig, Robert E.; Bruce, James F.

    2010-01-01

    State and local agencies are concerned about the effects of increasing urban development and human population growth on water quality and the biological condition of regional streams in the Eagle River watershed. In response to these needs, the U.S. Geological Survey initiated a study in cooperation with the Colorado River Water Conservation District, Eagle County, Eagle River Water and Sanitation District, Upper Eagle Regional Water Authority, Colorado Department of Transportation, City of Aurora, Town of Eagle, Town of Gypsum, Town of Minturn, Town of Vail, Vail Resorts, Colorado Springs Utilities, Denver Water, and the U.S. Department of Agriculture Forest Service. As part of this study, previously collected macroinvertebrate and algal data from the Eagle River watershed were compiled. This report includes macroinvertebrate data collected by the U.S. Geological Survey and(or) the U.S. Department of Agriculture Forest Service from 73 sites from 2000 to 2007 and algal data collected from up to 26 sites between 2000 and 2001 in the Eagle River watershed. Additionally, a brief description of the sample collection methods and data processing procedures are presented.

  2. Aerosol Sampling System for Collection of Capstone Depleted Uranium Particles in a High-Energy Environment

    SciTech Connect

    Holmes, Thomas D.; Guilmette, Raymond A.; Cheng, Yung-Sung; Parkhurst, MaryAnn; Hoover, Mark D.

    2009-03-01

    The Capstone Depleted Uranium Aerosol Study was undertaken to obtain aerosol samples resulting from a kinetic-energy cartridge with a large-caliber depleted uranium (DU) penetrator striking an Abrams or Bradley test vehicle. The sampling strategy was designed to (1) optimize the performance of the samplers and maintain their integrity in the extreme environment created during perforation of an armored vehicle by a DU penetrator, (2) collect aerosols as a function of time post-impact, and (3) obtain size-classified samples for analysis of chemical composition, particle morphology, and solubility in lung fluid. This paper describes the experimental setup and sampling methodologies used to achieve these objectives. Custom-designed arrays of sampling heads were secured to the inside of the target in locations approximating the breathing zones of the vehicle commander, loader, gunner, and driver. Each array was designed to support nine filter cassettes and nine cascade impactors mounted with quick-disconnect fittings. Shielding and sampler placement strategies were used to minimize sampler loss caused by the penetrator impact and the resulting fragments of eroded penetrator and perforated armor. A cyclone train was used to collect larger quantities of DU aerosol for chemical composition and solubility. A moving filter sample was used to obtain semicontinuous samples for depleted uranium concentration determination. Control for the air samplers was provided by five remotely located valve control and pressure monitoring units located inside and around the test vehicle. These units were connected to a computer interface chassis and controlled using a customized LabVIEW engineering computer control program. The aerosol sampling arrays and control systems for the Capstone study provided the needed aerosol samples for physicochemical analysis, and the resultant data were used for risk assessment of exposure to DU aerosol.

  3. Chemical analyses of soil samples collected from the Sandia National Laboratories/NM, Tonopah Test Range environs, 1994-2005.

    SciTech Connect

    Deola, Regina Anne; Oldewage, Hans D.; Herrera, Heidi M.; Miller, Mark Laverne

    2006-05-01

    From 1994 through 2005, the Environmental Management Department of Sandia National Laboratories (SNL) at the Tonopah Test Range (TTR), NV, has collected soil samples at numerous locations on-site, on the perimeter, and off-site for the purpose of determining potential impacts to the environs from operations at TTR. These samples were submitted to an analytical laboratory of metal-in-soil analyses. Intercomparisons of these results were then made to determine if there was any statistical difference between on-site, perimeter, and off-site samples, or if there were increasing or decreasing trends which indicated that further investigation may be warranted. This work provided the SNL Environmental Management Department with a sound baseline data reference against which to compare future operational impacts. In addition, it demonstrates the commitment that the Laboratories have to go beyond mere compliance to achieve excellence in its operations. This data is presented in graphical format with narrative commentaries on particular items of interest.

  4. Alkylphenol polyethoxylate derivatives in groundwater and blood samples collected from pig herds in Taiwan.

    PubMed

    Chiu, Tai-Shun; Hsieh, Chi-Ying; Miaw, Chang-Ling; Lin, Chao-Nan; Chang, Tsung-Chou; Yen, Chia-Hung; Chiou, Ming-Tang

    2014-07-01

    Alkylphenol polyethoxylate (APEO) derivatives, such as nonylphenol monoethoxylate (NP1EO), nonylphenol diethoxylate (NP2EO), nonylphenol (NP) and octylphenol (OP), have been detected in the surface water, sediment, food and groundwater of numerous countries. Because groundwater is the main source of water for pig herds, the aim of this study was to measure the concentrations of APEO derivatives in groundwater and blood samples that were collected from pig herds raised near the Wuluo River in Southern Taiwan. The mean concentrations of NP, OP, NP1EO and NP2EO in the groundwater supply for 10 pig herds were 0.04 µg/l, 0.26 ± 0.23 µg/l, 0.74 ± 0.69 µg/l and 0.17 ± 0.22 µg/l, respectively. NP was detected in all blood samples collected from 5 of the 10 pig herds. The highest concentrations detected in the blood samples collected from six-week-old piglets and sows were 12.00 µg/l and 56.94 µg/l, respectively. Blood samples from 4 of the 5 herds showed OP contamination. The highest OP concentrations detected in 6-week-old piglets and sows were 275.58 µg/l and 566.32 µg/l, respectively. These results indicate that APEO derivatives accumulated in the groundwater supply and the bloodstreams of the pigs.

  5. A supplement to "Methods for collection and analysis of aquatic biological and microbiological samples"

    USGS Publications Warehouse

    1979-01-01

    The report contains methods used by the U.S. Geological Survey to collect, preserve, and analyze waters to determine their biological and microbiological properties. It supplements, "Methods for Collection and Analysis of Aquatic Biological and Microbiological Samples" (TWRI, Book 5, Chapter A4, 1977, edited by P. E. Greeson, T. A. Ehlke, G. A. Irwin, B. W. Lium, and K. V. Slack). Included in the supplement are 5 new methods, a new section of selected taxonomic references for Ostracoda, and 6 revised methods.

  6. Curating NASA's future extraterrestrial sample collections: How do we achieve maximum proficiency?

    NASA Astrophysics Data System (ADS)

    McCubbin, Francis; Evans, Cynthia; Allton, Judith; Fries, Marc; Righter, Kevin; Zolensky, Michael; Zeigler, Ryan

    2016-07-01

    Introduction: The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10E "Curation of Extraterrestrial Materials", JSC is charged with "The curation of all extraterrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "…documentation, preservation, preparation, and distribution of samples for research, education, and public outreach." Here we describe some of the ongoing efforts to ensure that the future activities of the NASA Curation Office are working to-wards a state of maximum proficiency. Founding Principle: Curatorial activities began at JSC (Manned Spacecraft Center before 1973) as soon as design and construction planning for the Lunar Receiving Laboratory (LRL) began in 1964 [1], not with the return of the Apollo samples in 1969, nor with the completion of the LRL in 1967. This practice has since proven that curation begins as soon as a sample return mission is conceived, and this founding principle continues to return dividends today [e.g., 2]. The Next Decade: Part of the curation process is planning for the future, and we refer to these planning efforts as "advanced curation" [3]. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of collections as envisioned by NASA exploration goals. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, curation of organically- and biologically-sensitive samples, and the use of minimally invasive analytical techniques (e.g., micro-CT, [4]) to characterize samples. These efforts will be useful for Mars Sample Return

  7. 76 FR 24854 - Proposed Information Collection; Comment Request; Additional Protocol Report Forms

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-03

    ... International Atomic Energy Agency (IAEA) on a number of commercial nuclear and nuclear-related items, materials... for a nuclear weapons program. These forms provides the IAEA with information about additional aspects...; buildings on sites of facilities selected by the IAEA from the U.S. Eligible Facilities List;...

  8. The U.S. Geological Survey Geologic Collections Management System (GCMS)—A master catalog and collections management plan for U.S. Geological Survey geologic samples and sample collections

    USGS Publications Warehouse

    ,

    2015-01-01

    The general consideration for implementation of the GCMS is that all active USGS geologic sample repositories will form the core of GCMS and that participating science centers will develop procedures based on proposed GCMS methodologies. The GCMS is a collective resource for the entire USGS community and the users who discover the geologic materials kept in these repositories and seek to access them.

  9. Multiple Approaches to Down Sizing of the Lunar Sample Return Collection

    NASA Technical Reports Server (NTRS)

    Lofgren, Gary E.; Horz, F.

    2010-01-01

    Future Lunar missions are planned for at least 7 days, significantly longer than the 3 days of the later Apollo missions. The last of those missions, A-17, returned 111 kg of samples plus another 20 kg of containers. The current Constellation program requirements for return weight for science is 100 kg with the hope of raising that limit to near 250 kg including containers and other non-geological materials. The estimated return weight for rock and soil samples will, at best, be about 175 kg. One method proposed to accomplish down-sizing of the collection is the use of a Geo-Lab in the lunar habitat to complete a preliminary examination of selected samples and facilitate prioritizing the return samples.

  10. Efficient Genome-Wide Sequencing and Low-Coverage Pedigree Analysis from Noninvasively Collected Samples

    PubMed Central

    Snyder-Mackler, Noah; Majoros, William H.; Yuan, Michael L.; Shaver, Amanda O.; Gordon, Jacob B.; Kopp, Gisela H.; Schlebusch, Stephen A.; Wall, Jeffrey D.; Alberts, Susan C.; Mukherjee, Sayan; Zhou, Xiang; Tung, Jenny

    2016-01-01

    Research on the genetics of natural populations was revolutionized in the 1990s by methods for genotyping noninvasively collected samples. However, these methods have remained largely unchanged for the past 20 years and lag far behind the genomics era. To close this gap, here we report an optimized laboratory protocol for genome-wide capture of endogenous DNA from noninvasively collected samples, coupled with a novel computational approach to reconstruct pedigree links from the resulting low-coverage data. We validated both methods using fecal samples from 62 wild baboons, including 48 from an independently constructed extended pedigree. We enriched fecal-derived DNA samples up to 40-fold for endogenous baboon DNA and reconstructed near-perfect pedigree relationships even with extremely low-coverage sequencing. We anticipate that these methods will be broadly applicable to the many research systems for which only noninvasive samples are available. The lab protocol and software (“WHODAD”) are freely available at www.tung-lab.org/protocols-and-software.html and www.xzlab.org/software.html, respectively. PMID:27098910

  11. Efficient Genome-Wide Sequencing and Low-Coverage Pedigree Analysis from Noninvasively Collected Samples.

    PubMed

    Snyder-Mackler, Noah; Majoros, William H; Yuan, Michael L; Shaver, Amanda O; Gordon, Jacob B; Kopp, Gisela H; Schlebusch, Stephen A; Wall, Jeffrey D; Alberts, Susan C; Mukherjee, Sayan; Zhou, Xiang; Tung, Jenny

    2016-06-01

    Research on the genetics of natural populations was revolutionized in the 1990s by methods for genotyping noninvasively collected samples. However, these methods have remained largely unchanged for the past 20 years and lag far behind the genomics era. To close this gap, here we report an optimized laboratory protocol for genome-wide capture of endogenous DNA from noninvasively collected samples, coupled with a novel computational approach to reconstruct pedigree links from the resulting low-coverage data. We validated both methods using fecal samples from 62 wild baboons, including 48 from an independently constructed extended pedigree. We enriched fecal-derived DNA samples up to 40-fold for endogenous baboon DNA and reconstructed near-perfect pedigree relationships even with extremely low-coverage sequencing. We anticipate that these methods will be broadly applicable to the many research systems for which only noninvasive samples are available. The lab protocol and software ("WHODAD") are freely available at www.tung-lab.org/protocols-and-software.html and www.xzlab.org/software.html, respectively. PMID:27098910

  12. Enhanced Conformational Sampling Using Replica Exchange with Collective-Variable Tempering.

    PubMed

    Gil-Ley, Alejandro; Bussi, Giovanni

    2015-03-10

    The computational study of conformational transitions in RNA and proteins with atomistic molecular dynamics often requires suitable enhanced sampling techniques. We here introduce a novel method where concurrent metadynamics are integrated in a Hamiltonian replica-exchange scheme. The ladder of replicas is built with different strengths of the bias potential exploiting the tunability of well-tempered metadynamics. Using this method, free-energy barriers of individual collective variables are significantly reduced compared with simple force-field scaling. The introduced methodology is flexible and allows adaptive bias potentials to be self-consistently constructed for a large number of simple collective variables, such as distances and dihedral angles. The method is tested on alanine dipeptide and applied to the difficult problem of conformational sampling in a tetranucleotide.

  13. Enhanced Conformational Sampling Using Replica Exchange with Collective-Variable Tempering

    PubMed Central

    2015-01-01

    The computational study of conformational transitions in RNA and proteins with atomistic molecular dynamics often requires suitable enhanced sampling techniques. We here introduce a novel method where concurrent metadynamics are integrated in a Hamiltonian replica-exchange scheme. The ladder of replicas is built with different strengths of the bias potential exploiting the tunability of well-tempered metadynamics. Using this method, free-energy barriers of individual collective variables are significantly reduced compared with simple force-field scaling. The introduced methodology is flexible and allows adaptive bias potentials to be self-consistently constructed for a large number of simple collective variables, such as distances and dihedral angles. The method is tested on alanine dipeptide and applied to the difficult problem of conformational sampling in a tetranucleotide. PMID:25838811

  14. Design of a multi-level monitoring well for continuous sample collection

    SciTech Connect

    Ayers, J.F.; Gosselin, D.C.

    1995-12-31

    As part of a study of the flow dynamics and sampling environment around a high-capacity irrigation well, it was necessary to design and install a multi-level monitoring well network close to the production well. A requirement of the monitoring well network was the capability of continuous pumping over periods typical of those used during water sample collection. This was accomplished through the uses of a control valve and air manifold system connected to a common gasoline engine-operated ar compressor. The system provided adequate air pressure to operate 24 half-size bladder pumps to depths between 21 feet (6.4 m) and 56 feet (17.1 m) below the surface. Preliminary data collected from the monitoring well network indicate that the system will meet the requirements of the high-capacity well study.

  15. [Methods for sampling, collecting, preserving and carrying materials for parasitic tests (author's transl)].

    PubMed

    Penna, R

    1977-01-01

    A review is made of the methods of sampling, collecting, preserving and carrying materials to search directly (by microscopical, cultural or biological tests) the most common human parasites: protozoa, helminths and arthropods, with some references of indirect, specific (immunological) and aspecific (hematological, biochemical, immunochemical) procedures to search signs of parasitoses. The aim of this paper is to propose a standardization of these procedures for protozoa, helminth and arthropod infections. PMID:356770

  16. STS-55 Payload Specialist Schlegel collects fungi sample at SL-D2 Rack 1

    NASA Technical Reports Server (NTRS)

    1993-01-01

    STS-55 German Payload Specialist 2 Hans Schlegel, wearing lightweight headset, collects fungi sample while working at Spacelab Deutsche 2 (SL-D2) science module Rack 1 Work Bench. Schlegel is conducting these procedures in conjunction with the 'Fruiting Body Development of Fungi' experiment. Schlegel was one of two payload specialists representing the German Aerospace Research Establishment (DLR) on the 10-day spacelab mission.

  17. STS-55 Payload Specialist Schlegel collects fungi sample at SL-D2 Rack 1

    NASA Technical Reports Server (NTRS)

    1993-01-01

    STS-55 German Payload Specialist 2 Hans Schlegel, wearing lightweight headset, collects fungi sample while working at Spacelab Deutsche 2 (SL-D2) science module Rack 1 Work Bench. Schlegel is conducting these procedures in conjunction with the 'Fruiting Body Development of Fungi' experiment. Pieces of the experiment casing freefloat in the workstation.Schlegel represents the German Aerospace Research Establishment (DLR) on the 10-day spacelab mission.

  18. Vapor space characterization of waste tank 241-C-105: Results from samples collected on 2/16/94

    SciTech Connect

    Clauss, T.W.; Lucke, R.B.; McVeety, B.D.

    1995-06-01

    This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-C-105 (referred to as Tank C-105). Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace. For organic analyses, six SUMMA{trademark} canisters were delivered to WHC on COC 0061 11 on 2/14/94. At the request of WHC, an additional six SUMMA{trademark} canisters were supplied on COC 005127 on 2/16/94. Samples were collected by WHC from the headspace of Tank C-105 through the VSS on 2/16/94, but only three SUMMA{sup {trademark}} canisters were returned to PNL using COC 0061 11 on 2/18/94. The canisters were stored in the 326/23B laboratory at ambient (25{degrees}C) temperature until the time of the analysis. Analyses described in this report were performed at PNL in the 300 area of the Hanford Reservation. Analytical methods that were used are described in the text. In summary, sorbent traps for inorganic analyses containing sample materials were either weighed (for water analysis) or desorbed with the appropriate aqueous solutions. The aqueous extracts were analyzed either by selective electrode or by ion chromatography (IC). Organic analyses were performed using cryogenic preconcentration followed by gas chromatography/mass spectrometry (GC/MS).

  19. Tank 241-TY-104 headspace gas and vapor characterization results for samples collected in April 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  20. Tank 241-C-104 headspace gas and vapor characterization results for samples collected in March 1994

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-28

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  1. Tank 241-AX-102 headspace gas and vapor characterization results for samples collected in June 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  2. Tank 241-SX-106 headspace gas and vapor characterization results for samples collected in March 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  3. Tank 241-SX-103 headspace gas and vapor characterization results for samples collected in March 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  4. Tank 241-A-101 headspace gas and vapor characterization results for samples collected in June 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  5. Tank 241-T-107 Headspace Gas and Vapor Characterization Results for Samples Collected in January 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-26

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  6. Tank 241-T-111 headspace gas and vapor characterization results for samples collected in January 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  7. Tank 241-C-101 headspace gas and vapor characterization results for samples collected in September 1994

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  8. Tank 241-S-111 headspace gas and vapor characterization results for samples collected in March 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  9. Tank 241-U-107 headspace gas and vapor characterization results for samples collected in February 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  10. Tank 241-U-111 headspace gas and vapor characterization results for samples collected in February 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  11. Tank 241-U-103 headspace gas and vapor characterization results for samples collected in February 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-27

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  12. Tank 241-C-110 headspace gas and vapor characterization results for samples collected in August 1994

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  13. Determination of trace elements in volcanic rock samples collected from cenozoic lava eruption sites using LIBS.

    PubMed

    Gondal, Mohammed A; Nasr, Mohamed M; Ahmed, Zulfiqar; Yamani, Zain H

    2009-04-01

    Trace elements of environmental significance present in the volcanic rock samples collected from sites of the Cenozoic era flood basalt flows and eruptions were detected using locally developed laser-induced breakdown spectrometer. For spectro-chemical analysis of these samples, the plasma was generated by focusing a pulsed Nd: YAG laser radiation at 1064 nm wavelength on the target rock samples. These samples were collected from four widely separated locations surrounding the volcanic eruption sites belonging to the Harrat Hutaymah volcanic field in the vicinity of Taba town, situated to the east of Hail city of northern Saudi Arabia. These samples represent the scoria basalt lava flows as well as a large tuff-ring crater and it contains xenoliths. These flows occur widespread over the Earth's surface in this region, and their contained xenoliths are brought up from depths of a few tens of kilometers. This volcanic field has received much less attention in the previous geological studies; and consequently, its effects on the environment are not well defined. The concentration of different elements of environmental significance like Cr, Pb, Mn, Cd, Sr and other trace metals like Cu, Al, Ca, Mg, Zn, Ti and Fe in these rock samples were determined by spectral analysis. Parametric dependence for improvement of LIBS sensitivity for detection of these elements was also carried out. The highest concentration detected of environmentally significant elements like Cr, Mn, Pb, Sr and Ni are 1910, 1399, 90.5, 12412 and 461.5 ppm, respectively in four different lava samples which are considered to be much higher than the safe permissible limits. The LIBS results were compared with the results obtained using other analytical techniques such as the inductively coupled plasma atomic emission spectroscopy (ICP-AES).

  14. Analysis of Tank 43H Samples at the Conclusion of Uranyl Carbonate Addition

    SciTech Connect

    Oji, L.N.

    2002-10-15

    Tank 43H serves as the feed Tank to the 2H evaporator. In the months of July and August 2001, about 21,000 gallons of a depleted uranyl carbonate solution were added to Tank 43H and agitated with two Flygt mixers. The depleted uranium addition served to decrease the U-235 enrichment in the Tank 43H supernate so that the supernate could be evaporated with no risk of accumulating enriched uranium.

  15. Microbeam Characterization of Corning Archeological Reference Glasses: New Additions to the Smithsonian Microbeam Standard Collection

    PubMed Central

    Vicenzi, Edward P.; Eggins, Stephen; Logan, Amelia; Wysoczanski, Richard

    2002-01-01

    An initial study of the minor element, trace element, and impurities in Corning archeological references glasses have been performed using three microbeam techniques: electron probe microanalysis (EPMA), laser ablation ICP-mass spectrometry (LA ICP-MS), and secondary ion mass spectrometry (SIMS). The EPMA results suggest a significant level of heterogeneity for a number of metals. Conversely, higher precision and a larger sampling volume analysis by LA ICP-MS indicates a high degree of chemical uniformity within all glasses, typically <2 % relative (1 σ). SIMS data reveal that small but measurable quantities of volatile impurities are present in the glasses, including H at roughly the 0.0001 mass fraction level. These glasses show promise for use as secondary standards for minor and trace element analyses of insulating materials such as synthetic ceramics, minerals, and silicate glasses. PMID:27446764

  16. Non-uniform sampling: post-Fourier era of NMR data collection and processing.

    PubMed

    Kazimierczuk, Krzysztof; Orekhov, Vladislav

    2015-11-01

    The invention of multidimensional techniques in the 1970s revolutionized NMR, making it the general tool of structural analysis of molecules and materials. In the most straightforward approach, the signal sampling in the indirect dimensions of a multidimensional experiment is performed in the same manner as in the direct dimension, i.e. with a grid of equally spaced points. This results in lengthy experiments with a resolution often far from optimum. To circumvent this problem, numerous sparse-sampling techniques have been developed in the last three decades, including two traditionally distinct approaches: the radial sampling and non-uniform sampling. This mini review discusses the sparse signal sampling and reconstruction techniques from the point of view of an underdetermined linear algebra problem that arises when a full, equally spaced set of sampled points is replaced with sparse sampling. Additional assumptions that are introduced to solve the problem, as well as the shape of the undersampled Fourier transform operator (visualized as so-called point spread function), are shown to be the main differences between various sparse-sampling methods.

  17. Non-uniform sampling: post-Fourier era of NMR data collection and processing.

    PubMed

    Kazimierczuk, Krzysztof; Orekhov, Vladislav

    2015-11-01

    The invention of multidimensional techniques in the 1970s revolutionized NMR, making it the general tool of structural analysis of molecules and materials. In the most straightforward approach, the signal sampling in the indirect dimensions of a multidimensional experiment is performed in the same manner as in the direct dimension, i.e. with a grid of equally spaced points. This results in lengthy experiments with a resolution often far from optimum. To circumvent this problem, numerous sparse-sampling techniques have been developed in the last three decades, including two traditionally distinct approaches: the radial sampling and non-uniform sampling. This mini review discusses the sparse signal sampling and reconstruction techniques from the point of view of an underdetermined linear algebra problem that arises when a full, equally spaced set of sampled points is replaced with sparse sampling. Additional assumptions that are introduced to solve the problem, as well as the shape of the undersampled Fourier transform operator (visualized as so-called point spread function), are shown to be the main differences between various sparse-sampling methods. PMID:26290057

  18. Standard addition flow method for potentiometric measurements at low concentration levels: application to the determination of fluoride in food samples.

    PubMed

    Galvis-Sánchez, Andrea C; Santos, João Rodrigo; Rangel, António O S S

    2015-02-01

    A standard addition method was implemented by using a flow manifold able to perform automatically multiple standard additions and in-line sample treatment. This analytical strategy was based on the in-line mixing of sample and standard addition solutions, using a merging zone approach. The flow system aimed to exploit the standard addition method to quantify the target analyte particularly in cases where the analyte concentration in the matrix is below the lower limit of linear response of the detector. The feasibility of the proposed flow configuration was assessed through the potentiometric determination of fluoride in sea salts of different origins and different types of coffee infusions. The limit of quantification of the proposed manifold was 5×10(-6) mol L(-1), 10-fold lower than the lower limit of linear response of the potentiometric detector used. A determination rate of 8 samples h(-1) was achieved considering an experimental procedure based on three standard additions per sample. The main advantage of the proposed strategy is the simple approach to perform multiple standard additions, which can be implemented with other ion selective electrodes, especially in cases when the primary ion is below the lower limit of linear response of the detector.

  19. Pesticide-sampling equipment, sample-collection and processing procedures, and water-quality data at Chicod Creek, North Carolina, 1992

    USGS Publications Warehouse

    Manning, T.K.; Smith, K.E.; Wood, C.D.; Williams, J.B.

    1994-01-01

    Water-quality samples were collected from Chicod Creek in the Coastal Plain Province of North Carolina during the summer of 1992 as part of the U.S. Geological Survey's National Water-Quality Assessment Program. Chicod Creek is in the Albemarle-Pamlico drainage area, one of four study units designated to test equipment and procedures for collecting and processing samples for the solid-phase extraction of selected pesticides, The equipment and procedures were used to isolate 47 pesticides, including organonitrogen, carbamate, organochlorine, organophosphate, and other compounds, targeted to be analyzed by gas chromatography/mass spectrometry. Sample-collection and processing equipment equipment cleaning and set-up procedures, methods pertaining to collecting, splitting, and solid-phase extraction of samples, and water-quality data resulting from the field test are presented in this report Most problems encountered during this intensive sampling exercise were operational difficulties relating to equipment used to process samples.

  20. Regression modeling of particle size distributions in urban storm water: advancements through improved sample collection methods

    USGS Publications Warehouse

    Fienen, Michael N.; Selbig, William R.

    2012-01-01

    A new sample collection system was developed to improve the representation of sediment entrained in urban storm water by integrating water quality samples from the entire water column. The depth-integrated sampler arm (DISA) was able to mitigate sediment stratification bias in storm water, thereby improving the characterization of suspended-sediment concentration and particle size distribution at three independent study locations. Use of the DISA decreased variability, which improved statistical regression to predict particle size distribution using surrogate environmental parameters, such as precipitation depth and intensity. The performance of this statistical modeling technique was compared to results using traditional fixed-point sampling methods and was found to perform better. When environmental parameters can be used to predict particle size distributions, environmental managers have more options when characterizing concentrations, loads, and particle size distributions in urban runoff.

  1. Presence of aflatoxin M1 in raw, reconstituted, and powdered milk samples collected in Algeria.

    PubMed

    Redouane-Salah, S; Morgavi, D P; Arhab, R; Messaï, A; Boudra, H

    2015-06-01

    Aflatoxins are potent toxic metabolites produced by Aspergillus spp. Aflatoxin M1 (AFM1) is a metabolite of aflatoxin B1 that can be present in milk, and it is a public health concern. There is scarce information on the incidence of aflatoxin M1 contamination in milk consumed in Algeria. The presence of AFM1 was investigated in raw milk samples collected between February and October 2011 from 11 dairy farms representative of Algerian production conditions and that were located around Constantine city. Reconstituted and powdered milk samples were purchased from local supermarkets. The analysis was performed by liquid chromatography-fluorescence detection after immunoaffinity purification. AFM1 was detected in 5 out of 47 samples (11 %) at levels ranging from 9 to 103 ng/L, with one sample exceeding the limit of 50 ng/L set by European regulations. Traces of AFM1 (less than 8 ng/L) were also found in 11 other samples. The incidence of AFM1 contamination was higher in imported powdered milk (29 %) than in raw milk (5 %). Although the concentration of AFM1 in contaminated samples was low, the relatively considerable prevalence found in this exploratory study justifies more detailed and continuous monitoring to reduce consumers' exposure to AFM1.

  2. Aqueous Processing of Atmospheric Organic Particles in Cloud Water Collected via Aircraft Sampling.

    PubMed

    Boone, Eric J; Laskin, Alexander; Laskin, Julia; Wirth, Christopher; Shepson, Paul B; Stirm, Brian H; Pratt, Kerri A

    2015-07-21

    Cloudwater and below-cloud atmospheric particle samples were collected onboard a research aircraft during the Southern Oxidant and Aerosol Study (SOAS) over a forested region of Alabama in June 2013. The organic molecular composition of the samples was studied to gain insights into the aqueous-phase processing of organic compounds within cloud droplets. High resolution mass spectrometry (HRMS) with nanospray desorption electrospray ionization (nano-DESI) and direct infusion electrospray ionization (ESI) were utilized to compare the organic composition of the particle and cloudwater samples, respectively. Isoprene and monoterpene-derived organosulfates and oligomers were identified in both the particles and cloudwater, showing the significant influence of biogenic volatile organic compound oxidation above the forested region. While the average O:C ratios of the organic compounds were similar between the atmospheric particle and cloudwater samples, the chemical composition of these samples was quite different. Specifically, hydrolysis of organosulfates and formation of nitrogen-containing compounds were observed for the cloudwater when compared to the atmospheric particle samples, demonstrating that cloud processing changes the composition of organic aerosol.

  3. Aqueous Processing of Atmospheric Organic Particles in Cloud Water Collected via Aircraft Sampling

    SciTech Connect

    Boone, Eric J.; Laskin, Alexander; Laskin, Julia; Wirth, Christopher; Shepson, Paul B.; Stirm, Brian H.; Pratt, Kerri A.

    2015-07-21

    Cloud water and below-cloud atmospheric particle samples were collected onboard a research aircraft during the Southern Oxidant and Aerosol Study (SOAS) over a forested region of Alabama in June 2013. The organic molecular composition of the samples was studied to gain insights into the aqueous-phase processing of organic compounds within cloud droplets. High resolution mass spectrometry with nanospray desorption electrospray ionization and direct infusion electrospray ionization were utilized to compare the organic composition of the particle and cloud water samples, respectively. Isoprene and monoterpene-derived organosulfates and oligomers were identified in both the particles and cloud water, showing the significant influence of biogenic volatile organic compound oxidation above the forested region. While the average O:C ratios of the organic compounds were similar between the atmospheric particle and cloud water samples, the chemical composition of these samples was quite different. Specifically, hydrolysis of organosulfates and formation of nitrogen-containing compounds were observed for the cloud water when compared to the atmospheric particle samples, demonstrating that cloud processing changes the composition of organic aerosol.

  4. Aqueous Processing of Atmospheric Organic Particles in Cloud Water Collected via Aircraft Sampling.

    PubMed

    Boone, Eric J; Laskin, Alexander; Laskin, Julia; Wirth, Christopher; Shepson, Paul B; Stirm, Brian H; Pratt, Kerri A

    2015-07-21

    Cloudwater and below-cloud atmospheric particle samples were collected onboard a research aircraft during the Southern Oxidant and Aerosol Study (SOAS) over a forested region of Alabama in June 2013. The organic molecular composition of the samples was studied to gain insights into the aqueous-phase processing of organic compounds within cloud droplets. High resolution mass spectrometry (HRMS) with nanospray desorption electrospray ionization (nano-DESI) and direct infusion electrospray ionization (ESI) were utilized to compare the organic composition of the particle and cloudwater samples, respectively. Isoprene and monoterpene-derived organosulfates and oligomers were identified in both the particles and cloudwater, showing the significant influence of biogenic volatile organic compound oxidation above the forested region. While the average O:C ratios of the organic compounds were similar between the atmospheric particle and cloudwater samples, the chemical composition of these samples was quite different. Specifically, hydrolysis of organosulfates and formation of nitrogen-containing compounds were observed for the cloudwater when compared to the atmospheric particle samples, demonstrating that cloud processing changes the composition of organic aerosol. PMID:26068538

  5. The Apollo Lunar Sample Image Collection: Digital Archiving and Online Access

    NASA Technical Reports Server (NTRS)

    Todd, Nancy S.; Lofgren, Gary E.; Stefanov, William L.; Garcia, Patricia A.

    2014-01-01

    The primary goal of the Apollo Program was to land human beings on the Moon and bring them safely back to Earth. This goal was achieved during six missions - Apollo 11, 12, 14, 15, 16, and 17 - that took place between 1969 and 1972. Among the many noteworthy engineering and scientific accomplishments of these missions, perhaps the most important in terms of scientific impact was the return of 382 kg (842 lb.) of lunar rocks, core samples, pebbles, sand, and dust from the lunar surface to Earth. Returned samples were curated at JSC (then known as the Manned Spacecraft Center) and, as part of the original processing, high-quality photographs were taken of each sample. The top, bottom, and sides of each rock sample were photographed, along with 16 stereo image pairs taken at 45-degree intervals. Photographs were also taken whenever a sample was subdivided and when thin sections were made. This collection of lunar sample images consists of roughly 36,000 photographs; all six Apollo missions are represented.

  6. Effects of sample collection and storage methods on antipneumococcal immunoglobulin A in saliva.

    PubMed

    Nurkka, A; Obiero, J; Käyhty, H; Scott, J A G

    2003-05-01

    Saliva contains components of both the mucosal and systemic immune systems. Variable flow rates, immunoglobulin proteases, and variation in collection and storage methods all introduce differences in the estimated concentrations of antibodies. We evaluated the effect of four collection methods and three storage protocols on the concentrations of immunoglobulin A (IgA) antibodies to pneumococcal capsular antigens 1, 5, 6B, and 14 and to pneumococcal surface adhesin A (PsaA) in saliva. Specimens were collected from 30 healthy Kenyan adults by collecting drool, by pipette suction, and with two commercial kits, OraSure and Oracol. Aliquots from each specimen were snap-frozen with glycerol in liquid nitrogen or stored for 4 to 8 h at +4 degrees C either with or without the addition of protease enzyme inhibitors prior to storage at -70 degrees C. Anticapsular IgA concentrations were not significantly different with different collection methods, but snap-freezing the specimens in liquid nitrogen led to concentrations 41 to 47% higher than those of specimens stored by the other methods (P < 0.0005).

  7. Levels of organochlorine pesticide residues in butter samples collected from the Black Sea Region of Turkey.

    PubMed

    Aksoy, Abdurrahman; Dervisoglu, Muhammed; Guvenc, Dilek; Gul, Osman; Yazici, Fehmi; Atmaca, Enes

    2013-01-01

    The aim of the present study was to evaluate the levels of 9 organochlorine compounds (aldrin, hexachlorobenzene, 2,4-DDE, 4,4-DDE, 2,4-DDT, 4,4-DDT, and α-, β-, and γ-HCH) in butter samples collected in the Eastern, Middle and Western Black Sea Regions of Turkey between October 2009 and June 2010. The liquid-liquid extraction method was used to extract the organochlorine compounds from the samples and the measurements were performed by using a gas chromatograph-electron capture detector system. DDT metabolites, aldrin, hexachlorobenzene (HCB), and α-, and γ-HCH were not detected in the samples but β-HCH was detected in 3 of a total of 88 samples. In the first period, only one sample from the West Black Sea Region was β-HCH positive (0.014 mg kg(-1)). The other β-HCH positive samples collected in Middle and West Black Sea Regions in the second period had a concentration of 0.066 and 0.019 mg kg(-1), respectively. All concentrations of the detected compounds exceeded the legal limits of 0.003 mg kg(-1) for β-HCH, as prescribed by the Turkish Food Codex, and therefore pose a potential health risk for consumers. The contamination detected is most likely due to the past usage of β-HCH in agriculture and its long term persistence in the environment. These results strongly suggest that further research should be focused on the detection of pesticide residues in agricultural areas across the nation.

  8. Inactivation of Geobacillus stearothermophilus in canned food and coconut milk samples by addition of enterocin AS-48.

    PubMed

    Viedma, Pilar Martínez; Abriouel, Hikmate; Ben Omar, Nabil; López, Rosario Lucas; Valdivia, Eva; Gálvez, Antonio

    2009-05-01

    The cyclic bacteriocin enterocin AS-48 was tested on a cocktail of two Geobacillus stearothermophilus strains in canned food samples (corn and peas), and in coconut milk. AS-48 (7 microg/g) reduced viable cell counts below detection levels in samples from canned corn and peas stored at 45 degrees C for 30 days. In coconut milk, bacterial inactivation by AS-48 (1.75 microg/ml) was even faster. In all canned food and drink samples inoculated with intact G. stearothermophilus endospores, bacteriocin addition (1.75 microg per g or ml of food sample) rapidly reduced viable cell counts below detection levels and avoided regrowth during storage. After a short-time bacteriocin treatment of endospores, trypsin addition markedly increased G. stearothermophilus survival, supporting the effect of residual bacteriocin on the observed loss of viability for endospores. Results from this study support the potential of enterocin AS-48 as a biopreservative against G. stearothermophilus. PMID:19269571

  9. Estimation of actinide skeletal content in humans based on bone samples collected at autopsy.

    PubMed

    Filipy, R E; Alldredge, J R; Hall, C A; McInroy, J F; Glover, S E; Qualls, S

    2003-01-01

    The USTUR has developed simple linear and multiple regression models for estimating skeletal actinide concentrations on the basis of bone samples collected at autopsies of non-whole body tissue donors. Bone samples usually collected include a clavicle, the patella(e), one or more ribs, the sternum, and a vertebral wedge cut from within the abdominal cavity. The described models were derived by regression analyses with the analytical results from those bones and the entire skeletons of eight whole body donations to the USTUR. With the model, skeletal concentrations of 238Pu, (239+240)Pu, and 241Am can be estimated from wet or ashed actinide concentrations in one to five of the bones usually collected at autopsy and analyzed. Application of the models to a selected USTUR non-whole body donation (Case 0240) indicated that the skeletal actinide concentration estimates were reasonably precise and that there was good agreement between the results from individual bones with wet or ashed actinide concentrations. The USTUR will apply the model that is based on wet concentrations of bones to estimate skeletal concentrations of actinides in all non-whole body autopsy cases for the sake of consistency because of the large number of early cases for which ashed weights of bones were not recorded.

  10. [Logistics of collection and transportation of biological samples and the organization of the central laboratory in the ELSA-Brasil].

    PubMed

    Fedeli, Ligia G; Vidigal, Pedro G; Leite, Claudia Mendes; Castilhos, Cristina D; Pimentel, Robércia Anjos; Maniero, Viviane C; Mill, Jose Geraldo; Lotufo, Paulo A; Pereira, Alexandre C; Bensenor, Isabela M

    2013-06-01

    The ELSA (Estudo Longitudinal de Saúde do Adulto - Brazilian Longitudinal Study for Adult Health) is a multicenter cohort study which aims at the identification of risk factors associated with type 2 diabetes and cardiovascular diseases in the Brazilian population. The paper describes the strategies for the collection, processing, transportation, and quality control of blood and urine tests in the ELSA. The study decided to centralize the tests at one single laboratory. The processing of the samples was performed at the local laboratories, reducing the weight of the material to be transported, and diminishing the costs of transportation to the central laboratory at the Universidade de São Paulo Hospital. The study included tests for the evaluation of diabetes, insulin resistance, dyslipidemia, electrolyte abnormalities, thyroid hormones, uric acid, hepatic enzyme abnormalities, inflammation, and total blood cell count. In addition, leukocyte DNA, urine, plasma and serum samples were stored. The central laboratory performed approximately 375,000 tests.

  11. Determination of boron contents in water samples collected from the Neelum valley, Azad Kashmir, Pakistan.

    PubMed

    Akram, Muhammad; Matiullah; Iqbal, Arshid; Husaini, S N; Malik, Fariha

    2011-03-01

    Intake of boron from food and drinking water may pose a risk to the public health above a certain concentration level. Therefore, knowledge of boron concentration in drinking water and food items is essential. In this context, samples of drinking water were collected from natural springs of the Neelum valley, Azad Kashmir, hit by devastating earthquake in 2005. In these samples, boron concentration was determined using neutron-induced radiography technique. To do so, unknown water samples, along with standard of known boron dried on CR-39 detectors, were irradiated with thermal neutrons. After exposure, CR-39 detectors were etched in 6 M NaOH at 70°C. The tracks produced due to the alpha particles and (7)Li ions as a result of (10)B(n,α)(7)Li reaction were counted under an optical microscope. The tracks produced in theses samples were then related to the boron contents. The measured boron concentration in water samples was found to vary from 0.105 ± 0.005 to 0.247 ± 0.013 mg/l with an average value of 0.17 ± 0.04 mg/l, which are within the acceptable limits.

  12. Comparative evaluation of vacuum-based surface sampling methods for collection of Bacillus spores.

    PubMed

    Calfee, M Worth; Rose, Laura J; Morse, Stephen; Mattorano, Dino; Clayton, Matt; Touati, Abderrahmane; Griffin-Gatchalian, Nicole; Slone, Christina; McSweeney, Neal

    2013-12-01

    In this study, four commonly-used sampling devices (vacuum socks, 37 mm 0.8 μm mixed cellulose ester (MCE) filter cassettes, 37 mm 0.3 μm polytetrafluoroethylene (PTFE) filter cassettes, and 3M™ forensic filters) were comparatively evaluated for their ability to recover surface-associated spores. Aerosolized spores (~10(5)CFUcm(-2)) of a Bacillus anthracis surrogate were allowed to settle onto three material types (concrete, carpet, and upholstery). Ten replicate samples were collected using each vacuum method, from each material type. Stainless steel surfaces, inoculated simultaneously with test materials, were sampled with pre-moistened wipes. Wipe recoveries were utilized to normalize vacuum-based recoveries across trials. Recovery (CFUcm(-2)) and relative recovery (vacuum recovery/wipe recovery) were determined for each method and material type. Recoveries and relative recoveries ranged from 3.8 × 10(3) to 7.4 × 10(4)CFUcm(-2) and 0.035 to 1.242, respectively. ANOVA results indicated that the 37 mm MCE method exhibited higher relative recoveries than the other methods when used for sampling concrete or upholstery. While the vacuum sock resulted in the highest relative recoveries on carpet, no statistically significant difference was detected. The results of this study may be used to guide selection of sampling approaches following biological contamination incidents.

  13. Diffraction cartography: applying microbeams to macromolecular crystallography sample evaluation and data collection.

    PubMed

    Bowler, Matthew W; Guijarro, Matias; Petitdemange, Sebastien; Baker, Isabel; Svensson, Olof; Burghammer, Manfred; Mueller-Dieckmann, Christoph; Gordon, Elspeth J; Flot, David; McSweeney, Sean M; Leonard, Gordon A

    2010-08-01

    Crystals of biological macromolecules often exhibit considerable inter-crystal and intra-crystal variation in diffraction quality. This requires the evaluation of many samples prior to data collection, a practice that is already widespread in macromolecular crystallography. As structural biologists move towards tackling ever more ambitious projects, new automated methods of sample evaluation will become crucial to the success of many projects, as will the availability of synchrotron-based facilities optimized for high-throughput evaluation of the diffraction characteristics of samples. Here, two examples of the types of advanced sample evaluation that will be required are presented: searching within a sample-containing loop for microcrystals using an X-ray beam of 5 microm diameter and selecting the most ordered regions of relatively large crystals using X-ray beams of 5-50 microm in diameter. A graphical user interface developed to assist with these screening methods is also presented. For the case in which the diffraction quality of a relatively large crystal is probed using a microbeam, the usefulness and implications of mapping diffraction-quality heterogeneity (diffraction cartography) are discussed. The implementation of these techniques in the context of planned upgrades to the ESRF's structural biology beamlines is also presented.

  14. Miniature CVD-diamond corning drills for robotic sample collection and analysis.

    SciTech Connect

    Vaniman, D. T.; Trava-Airoldi, V.J.; Bish, D. L.; Chipera, S. J.

    2003-01-01

    Coring tools have been used etlectivelv on the Moon, but to date no such tools have been used on any other extraterrestrial surface. The lunar experience includes both manual (Apollo) and robotic (Luna) systems . These coring systems were concerned primarily with acquiring samples from depth for return to Earth or for the creation of instrument emplacement holes (e .g ., heat probes). Current designs for planetary drills differ from the lunar tools primarily in that they are integrated with robotic instrumentation for remote analysis, but the role of the drilling or coring system remains one of acquiring samples that must be extracted from the core barrel for analysis . Missing from current sample collection systems is a tool that can double as both a conng device and a sample holder. This dual utility can minimize the number of motions, the mass, and the power required for several classes of instruments in planetary surface exploration. To be effective, such a system must be durable and simple in operation. Hollow CVD diamond drills possess the hardness, excellent cutting properties, and heat resistance required for drilling into a wide variety of rocks and minerals. Because CVD diamond is also unreactive and transparent to infrared radiation and to X-rays of moderate to high energry, it can be used as a sample holder in various instruments for X-ray diffraction (XRD), Xray fluorescence (XRF), infrared spectroscopy, Raman spectroscopy, and thermal analysis.

  15. Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure with image analysis

    DOEpatents

    Van Berkel, Gary J.; Kertesz, Vilmos

    2011-08-09

    A system and method utilizes an image analysis approach for controlling the collection instrument-to-surface distance in a sampling system for use, for example, with mass spectrometric detection. Such an approach involves the capturing of an image of the collection instrument or the shadow thereof cast across the surface and the utilization of line average brightness (LAB) techniques to determine the actual distance between the collection instrument and the surface. The actual distance is subsequently compared to a target distance for re-optimization, as necessary, of the collection instrument-to-surface during an automated surface sampling operation.

  16. Elemental analysis of Ginkgo biloba leaf samples collected during one vegetation period.

    PubMed

    Czigle, Szilvia; Háznagy-Radnai, Erzsébet; Pintye-Hódi, Klára; Tóth, Jaroslav; Tekel'ová, Daniela; Máthé, Imre

    2013-08-01

    The object of our work was the identification and quantification of inorganic elements in Ginkgo biloba L. leaves (Ginkgonis folium, Ginkgoaceae) by X-ray fluorescence analysis. The plant material was obtained from a 50-years-old female tree at the Comenius University Botanical Garden (Bratislava, Slovakia). Leaves were collected from early May to late September, with the last sample consisting of fallen leaves. The elements analyzed were: phosphorus, sulfur, potassium, calcium, scandium, iron, zinc, yttrium, molybdenum, tellurium, samarium, gadolinium, dysprosium, iridium, thallium and lead. The amounts of the monitored heavy metals were below the limits specified in Ph. Eur. 7 and PhS 1. PMID:24079191

  17. Percent recoveries of anthropogenic organic compounds with and without the addition of ascorbic acid to preserve finished-water samples containing free chlorine, 2004-10

    USGS Publications Warehouse

    Valder, Joshua F.; Delzer, Gregory C.; Bender, David A.; Price, Curtis V.

    2011-01-01

    This report presents finished-water matrix-spike recoveries of 270 anthropogenic organic compounds with and without the addition of ascorbic acid to preserve water samples containing free chlorine. Percent recoveries were calculated using analytical results from a study conducted during 2004-10 for the National Water-Quality Assessment (NAWQA) Program of the U.S. Geological Survey (USGS). The study was intended to characterize the effect of quenching on finished-water matrix-spike recoveries and to better understand the potential oxidation and transformation of 270 anthropogenic organic compounds. The anthropogenic organic compounds studied include those on analytical schedules 1433, 2003, 2033, 2060, 2020, and 4024 of the USGS National Water Quality Laboratory. Three types of samples were collected from 34 NAWQA locations across the Nation: (1) quenched finished-water samples (not spiked), (2) quenched finished-water matrix-spike samples, and (3) nonquenched finished-water matrix-spike samples. Percent recoveries of anthropogenic organic compounds in quenched and nonquenched finished-water matrix-spike samples are presented. Comparisons of percent recoveries between quenched and nonquenched spiked samples can be used to show how quenching affects finished-water samples. A maximum of 18 surface-water and 34 groundwater quenched finished-water matrix-spike samples paired with nonquenched finished-water matrix-spike samples were analyzed. Percent recoveries for the study are presented in two ways: (1) finished-water matrix-spike samples supplied by surface-water or groundwater, and (2) by use (or source) group category for surface-water and groundwater supplies. Graphical representations of percent recoveries for the quenched and nonquenched finished-water matrix-spike samples also are presented.

  18. Geochemistry of Rock Samples Collected from the Iron Hill Carbonatite Complex, Gunnison County, Colorado

    USGS Publications Warehouse

    Van Gosen, Bradley S.

    2008-01-01

    A study conducted in 2006 by the U.S. Geological Survey collected 57 surface rock samples from nine types of intrusive rock in the Iron Hill carbonatite complex. This intrusive complex, located in Gunnison County of southwestern Colorado, is known for its classic carbonatite-alkaline igneous geology and petrology. The Iron Hill complex is also noteworthy for its diverse mineral resources, including enrichments in titanium, rare earth elements, thorium, niobium (columbium), and vanadium. This study was performed to reexamine the chemistry and metallic content of the major rock units of the Iron Hill complex by using modern analytical techniques, while providing a broader suite of elements than the earlier published studies. The report contains the geochemical analyses of the samples in tabular and digital spreadsheet format, providing the analytical results for 55 major and trace elements.

  19. Effects of the number of people on efficient capture and sample collection: a lion case study.

    PubMed

    Ferreira, Sam M; Maruping, Nkabeng T; Schoultz, Darius; Smit, Travis R

    2013-01-01

    Certain carnivore research projects and approaches depend on successful capture of individuals of interest. The number of people present at a capture site may determine success of a capture. In this study 36 lion capture cases in the Kruger National Park were used to evaluate whether the number of people present at a capture site influenced lion response rates and whether the number of people at a sampling site influenced the time it took to process the collected samples. The analyses suggest that when nine or fewer people were present, lions appeared faster at a call-up locality compared with when there were more than nine people. The number of people, however, did not influence the time it took to process the lions. It is proposed that efficient lion capturing should spatially separate capture and processing sites and minimise the number of people at a capture site.

  20. Methods for collecting benthic invertebrate samples as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Cuffney, Thomas F.; Gurtz, Martin E.; Meador, Michael R.

    1993-01-01

    Benthic invertebrate communities are evaluated as part of the ecological survey component of the U.S. Geological Survey's National Water-Quality Assessment Program. These biological data are collected along with physical and chemical data to assess water-quality conditions and to develop an understanding of the factors that affect water-quality conditions locally, regionally, and nationally. The objectives of benthic invertebrate community characterizations are to (1) develop for each site a list of tax a within the associated stream reach and (2) determine the structure of benthic invertebrate communities within selected habitats of that reach. A nationally consistent approach is used to achieve these objectives. This approach provides guidance on site, reach, and habitat selection and methods and equipment for qualitative multihabitat sampling and semi-quantitative single habitat sampling. Appropriate quality-assurance and quality-control guidelines are used to maximize the ability to analyze data within and among study units.

  1. Ram-air sample collection device for a chemical warfare agent sensor

    DOEpatents

    Megerle, Clifford A.; Adkins, Douglas R.; Frye-Mason, Gregory C.

    2002-01-01

    In a surface acoustic wave sensor mounted within a body, the sensor having a surface acoustic wave array detector and a micro-fabricated sample preconcentrator exposed on a surface of the body, an apparatus for collecting air for the sensor, comprising a housing operatively arranged to mount atop the body, the housing including a multi-stage channel having an inlet and an outlet, the channel having a first stage having a first height and width proximate the inlet, a second stage having a second lower height and width proximate the micro-fabricated sample preconcentrator, a third stage having a still lower third height and width proximate the surface acoustic wave array detector, and a fourth stage having a fourth height and width proximate the outlet, where the fourth height and width are substantially the same as the first height and width.

  2. Apparatus for direct addition of reagents into a nuclear magnetic resonance (NMR) sample in the NMR probe

    NASA Astrophysics Data System (ADS)

    Perrin, Charles L.; Rivero, Ignacio A.

    1999-04-01

    Nuclear magnetic resonance (NMR) is a widely used tool in chemistry and biochemistry. It is occasionally necessary to add small aliquots of solvents or reagents repeatedly into the NMR tube. Ordinarily this is accomplished only by ejecting the sample and carrying out the addition outside the probe. It would be preferable to add the aliquot directly into the sample. We have designed and implemented a delivery system to accomplish this. This apparatus is particularly applicable to a recent NMR titration method for measuring relative pK's and to experiments where temperature must also be varied. This apparatus provides a safe, simple, and inexpensive method for repeated aliquot addition directly into the sample in the NMR probe.

  3. Combined-sewer overflow data and methods of sample collection for selected sites, Detroit, Michigan

    USGS Publications Warehouse

    Sweat, M.J.; Wolf, J.R.

    1997-01-01

    From October 1, 1994 through December 31, 1995, four combined-sewer discharging to the Detroit River in Detroit, Michigan were monitored to characterize storm-related water quantity and quality. Water velocity, stage, discharge, and precipitation were measured continuously and recorded at 5-minute intervals. Water-quality samples were collected at discrete times during each storm and analyzed for inorganic and organic pollutants. This report includes the sampling approach, field collection and processing techniques, and methods of chemical analysis, as well as a compilation of combined sewer discharge volumes, chemical data, and quality control data. These data may be used by resource managers and scientists (1) to describe temporal variation for pollutant concentrations in combined-sewage for various overflow events; (2) to describe spatial distribution of selected pollutants in the four combined-sewer overflows discharging to the Detroit River; (3) to calculate pollutant loads to the Detroit River from the four overflow sites for the monitored storm events; (4) to estimate pollutant loadings form other overflow sites; and, (5) to provide data and information which can be used to define appropriate management methods to reduce or eliminate untreated combined-sewer overflows. Selected combined-sewers were sampled between 30 and 82 times for inorganic pollutants, and between 14 and 22 times for organic pollutants, depending on the site. These samples represented between 8 and 17 storms during which one or more combined-sewers overflowed. The monitored pollutants included fecal coliform, fecal streptococci, and Escherichia coli; antimony, arsenic, beryllium, cadmium, hexavalent chromium, total chromium, cobalt, copper, iron, lead, manganese, mercury, nickel, silver, thallium and zinc; and polychlorinated biphenyl congeners, volatile organic compounds, and polynuclear aromatic hydrocarbons. In general, metal and non-metal inorganic pollutants were detected at all

  4. Molecular epidemiology of the human papillomavirus infection in self-collected samples from young women.

    PubMed

    de Almeida, Flávia Gatto; Machado, Ana Paula; Fernandes, Carlos Eurico Dos Santos; Ferreira, Alda Teixeira; Padovani, Cacilda Tezelli Junqueira; Tozetti, Inês Aparecida

    2014-02-01

    The prevalence of human papillomavirus (HPV) infection is the highest in young, sexually active women less than 35 years of age. Direct diagnosis of infection by enabling genotyping methods is important considering that the viral types are divided into high (HR-HPV) and low (LR-HPV) oncogenic risk. This study aimed to evaluate the epidemiological and molecular characteristics of HPV infection in self-collected samples from young women. A cross-sectional study of 245 sexually active students (18 to 35 years of age) was undertaken with self-collected samples. Extracted DNA was analyzed by polymerase chain reaction (PCR) with the PGMY 09/11 and PC04/GH20 primers for the detection of HPV DNA and the β-globin gene, respectively. Viral genotyping was performed by type-specific PCR (TS-PCR) and restriction fragment length polymorphism (RFLP). Of the 236 valid samples, 68 (28.9%) were positive for HPV DNA, as genotyped by TS-PCR and RFLP. The HR-HPV were most prevalent, especially HPV-16, -31, -33, and -45, and the most prevalent LR-HPV were HPV-6 and -83. Multi-type HPV infections were detected in 17 (25%) samples. HPV infection was statistically more prevalent among younger women with lower educational levels and who had more partners in the past 2 years. A high prevalence of HPV infection was found in the age group examined, especially HR-HPV types, as well as the presence of risk behaviors associated with HPV infection were observed. Considering these results, vaccinating females before the onset of sexual activity in Brazil should be emphasized.

  5. Vapor space characterization of Waste Tank 241-U-106 (in situ): Results from samples collected on 8/25/94

    SciTech Connect

    Ligotke, M.W.; Lucke, R.B.; Pool, K.H.

    1995-10-01

    This report describes inorganic and organic analyses results from in situ samples obtained from the headspace of the Hanford waste storage Tank 241-U-106 (referred to as Tank U-106). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water (H{sub 2}O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not performed. In addition, the authors looked for the 39 TO-14 compounds plus an additional 14 target analytes. Of these, six were observed above the 5-ppbv reporting cutoff. Ten organic tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv in two or more of the three samples collected and are reported with concentrations that are semiquantitative estimates based on internal standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 89% of the total organic components in Tank U-106. Methyl isocyanate, a compound of possible concern in Tank U-106, was not detected. Tank U-106 is on the Organic Watch List.

  6. EFFECT OF STORAGE TIME AND STORAGE CONDITIONS ON ANTIBODY DETECTION IN BLOOD SAMPLES COLLECTED ON FILTER PAPER.

    PubMed

    Bevins, Sarah; Pappert, Ryan; Young, John; Schmit, Brandon; Kohler, Dennis; Baeten, Laurie

    2016-07-01

    Using filter paper to collect blood from wildlife for antibody analysis can be a powerful technique to simplify the collection, transport, and storage of blood samples. Despite these advantages, there are limited data that detail how long these samples can be stored and how storage conditions affect antibody longevity. We used blood samples collected on filter paper from coyotes experimentally infected with Yersinia pestis to determine optimum sample storage conditions over time. Blood samples collected on filter paper were stored for 454 d or more in four groups: 1) at ambient temperature and at ambient relative humidity, 2) at ambient temperature with desiccant, 3) at 4 C with desiccant, and 4) at -20 C with desiccant. Samples stored at 4 C or -20 C with desiccant had detectable antibody for a longer period of time than the samples stored at room temperature. PMID:27187032

  7. Radon exhalation rate from the soil, sand and brick samples collected from NWFP and FATA, Pakistan.

    PubMed

    Rahman, Said; Mati, N; Matiullah; Ghauri, Badar

    2007-01-01

    In order to characterise the building materials as an indoor radon source, knowledge of the radon exhalation rate from these materials is very important. In this regard, soil, sand and brick samples were collected from different places of the North West Frontier Province (NWFP) and Federally Administered Tribal Areas (FATA), Pakistan. The samples were processed and placed in plastic containers. NRPB radon dosemeters were installed in it at heights of 25 cm above the surface of the samples and containers were then hermetically sealed. After 40-80 d of exposure to radon, CR-39 detectors were removed from the dosemeter holders and etched in 25% NaOH at 80 degrees C for 16 h. From the measured radon concentration values, (222)Rn exhalation rates were determined. Exhalation rate form soil, sand and brick samples was found to vary from 114 +/- 11 to 416 +/- 9 mBq m(-2) h(-1), 205 +/- 16 to 291 +/- 13 mBq m(-2) h(-1) and 245 +/- 12 to 365 +/- 11 mBq m(-2) h(-1), respectively.

  8. Activity concentrations of environmental samples collected in Fukushima Prefecture immediately after the Fukushima nuclear accident

    PubMed Central

    Hosoda, Masahiro; Tokonami, Shinji; Tazoe, Hirofumi; Sorimachi, Atsuyuki; Monzen, Satoru; Osanai, Minoru; Akata, Naofumi; Kakiuchi, Hideki; Omori, Yasutaka; Ishikawa, Tetsuo; Sahoo, Sarata K.; Kovács, Tibor; Yamada, Masatoshi; Nakata, Akifumi; Yoshida, Mitsuaki; Yoshino, Hironori; Mariya, Yasushi; Kashiwakura, Ikuo

    2013-01-01

    Radionuclide concentrations in environmental samples such as surface soils, plants and water were evaluated by high purity germanium detector measurements. The contribution rate of short half-life radionuclides such as 132I to the exposure dose to residents was discussed from the measured values. The highest values of the 131I/137Cs activity ratio ranged from 49 to 70 in the environmental samples collected at Iwaki City which is located to the south of the F1-NPS. On the other hand, the 132I/131I activity ratio in the same environmental samples had the lowest values, ranging from 0.01 to 0.02. By assuming that the 132I/131I activity ratio in the atmosphere was equal to the ratio in the environmental samples, the percent contribution to the thyroid equivalent dose by 132I was estimated to be less than 2%. Moreover, the contribution to the thyroid exposure by 132I might be negligible if 132I contamination was restricted to Iwaki City. PMID:23887080

  9. FWT and OBT concentrations in pine needle samples collected at Toki, Japan (1998-2012).

    PubMed

    Akata, N; Kakiuchi, H; Tamari, T; Tanaka, M; Kawano, T; Miyake, H; Uda, T; Nishimura, K

    2015-11-01

    Free water tritium (FWT) and organically bound tritium (OBT) concentrations in pine needles have been investigated to understand the regional background tritium concentration in Toki City. Samples were regularly collected from pine trees on the National Institute for Fusion Science campus (1998-2012) and the nearby Shiomi Park (SP; 2002-12). FWT and OBT concentrations of the former samples ranged from 0.33 to 0.92 and 0.41 to 1.10 Bq l(-1), respectively, while those of the latter samples ranged from 0.32 to 0.86 and 0.33 to 0.79 Bq l(-1), respectively. Results of both sampling sites were almost the same, and they have been gradually decreased year by year. Concentration level of tritium for Toki City was close to the average background level in Japan. The OBT/FWT ratios were almost 1.0. The apparent half-life of FWT in this period was estimated as almost 10 y, and that of OBT was estimated as almost 12 y; these values were almost the same as the physical half-life.

  10. Preliminary assessment of an economical fugitive road dust sampler for the collection of bulk samples for geochemical analysis.

    PubMed

    Witt, Emitt C; Wronkiewicz, David J; Shi, Honglan

    2013-01-01

    Fugitive road dust collection for chemical analysis and interpretation has been limited by the quantity and representativeness of samples. Traditional methods of fugitive dust collection generally focus on point-collections that limit data interpretation to a small area or require the investigator to make gross assumptions about the origin of the sample collected. These collection methods often produce a limited quantity of sample that may hinder efforts to characterize the samples by multiple geochemical techniques, preserve a reference archive, and provide a spatially integrated characterization of the road dust health hazard. To achieve a "better sampling" for fugitive road dust studies, a cyclonic fugitive dust (CFD) sampler was constructed and tested. Through repeated and identical sample collection routes at two collection heights (50.8 and 88.9 cm above the road surface), the products of the CFD sampler were characterized using particle size and chemical analysis. The average particle size collected by the cyclone was 17.9 μm, whereas particles collected by a secondary filter were 0.625 μm. No significant difference was observed between the two sample heights tested and duplicates collected at the same height; however, greater sample quantity was achieved at 50.8 cm above the road surface than at 88.9 cm. The cyclone effectively removed 94% of the particles >1 μm, which substantially reduced the loading on the secondary filter used to collect the finer particles; therefore, suction is maintained for longer periods of time, allowing for an average sample collection rate of about 2 g mi.

  11. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF SOIL SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.20)

    EPA Science Inventory

    This SOP describes the method for collecting soil samples from the child's outdoor play area to measure for persistent organic pollutants. Soil samples are collected by scraping up the top 0.5 cm of soil in a 0.095 m2 (1 ft2) area in the middle of the child's play area.

  12. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF DISLODGEABLE RESIDUES -- PUF ROLLER SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.18)

    EPA Science Inventory

    This SOP describes the method to collect transferable residues from indoor floor surfaces. The sampling procedures described are applicable to bare floors or covered floor surfaces, e.g., carpeting and vinyl flooring. The samples will be collected only in the day care centers o...

  13. Ground-Water Data-Collection Protocols and Procedures for the National Water-Quality Assessment Program: Collection and Documentation of Water-Quality Samples and Related Data

    USGS Publications Warehouse

    Koterba, Michael T.; Wilde, Franceska D.; Lapham, Wayne W.

    1995-01-01

    Protocols for ground-water sampling are described in a report written in 1989 as part of the pilot program for the National Water-Quality Assessment (NAWQA) Program of the U.S. Geological Survey (USGS). These protocols have been reviewed and revised to address the needs of the full-scale implementation of the NAWQA Program that began in 1991. This report, which is a collaborative effort between the NAWQA Program and the USGS Office of Water Quality, is the result of that review and revision. This report describes protocols and recommended procedures for the collection of water-quality samples and related data from wells for the NAWQA Program. Protocols and recommended procedures discussed include (1) equipment setup and other preparations for data collection; (2) well purging and field measurements; (3) collecting and processing ground-water-quality samples; (4) equipment decontamination; (5) quality-control sampling; and (6) sample handling and shipping.

  14. High volume electrostatic field-sampler for collection of fine particle bulk samples

    NASA Astrophysics Data System (ADS)

    Kumar Sharma, Anoop; Wallin, Håkan; Alstrup Jensen, Keld

    A high volume electrostatic field-sampler was developed for collection of fine particles, which easily can be recovered for subsequent sample characterisation and bioassays. The sampler was based on a commercial office air cleaner and consisted of a prefilter followed by electrostatic collection plates operating at 2.7 kV. The sampler performance was characterised for 26 nm to 5.4 μm-size particles in urban street air. The collection efficiency reached a maximum (60-70%) between 0.2 and 0.8 μm and dropped to ˜25% at 30 nm and 2.5 μm, respectively. After extraction in water, the particle loss was<2%. The extraction efficiency for dry lyophilised particulate matter was above 80%, allowing retrievement of ˜12 mg day -1 in urban street air at PM 10 levels of ˜24 μg m -3. The ozone generating capacity of the corona discharge during operation was on the order of 10 ppb. A polycyclic aromatic hydrocarbons (PAH) degradation test using benzo[a]pyrene as a model showed that ˜85% was degraded after 24 h. However, similar results were observed when the corona discharge was switched off. Hence, the ozone and other corona discharge reactants do not appear to contribute considerably to PAH-degradation. The overall results show that the sampler type is a promising alternative to traditional sampling of fine particles for bulk analysis and bioassays. The main advantages are simple operation, high stability, high quantifiable particle recovery rates and low cost.

  15. Extending the Collection Duration of Breath Samples for Enteric Methane Emission Estimation Using the SF6 Tracer Technique

    PubMed Central

    Pinares-Patiño, César; Gere, José; Williams, Karen; Gratton, Roberto; Juliarena, Paula; Molano, German; MacLean, Sarah; Sandoval, Edgar; Taylor, Grant; Koolaard, John

    2012-01-01

    Simple Summary Extended sample collection for the SF6 tracer technique is desirable for extensive grazing systems. Breath samples from eight cows were collected while lucerne silage was fed to achieve fixed intakes among the cows. Samples were collected over a 10-day period, using either apparatuses used in New Zealand (NZL) or Argentina (ARG), and either daily, over two consecutive 5-day periods or over a 10-day period (in duplicate). The NZL system had a greater sampling success and more consistent CH4 emission estimates than the ARG system, with no differences in mean emissions among sample collection periods. This study showed that extended sample collection is feasible, but definitive evaluation under grazing situation is required before a decision on recommendation can be made. Abstract The daily sample collection protocol of the sulphur hexafluoride (SF6) tracer technique for the estimation of methane (CH4) emissions from ruminants may not be practical under extensive grazing systems. Here, under controlled conditions, we evaluated extended periods of sampling as an alternative to daily sample collections. Eight rumen-fistulated cows were housed and fed lucerne silage to achieve common daily feed intakes of 6.4 kg dry matter per cow. Following SF6 permeation tube dosing, eight sampling lines were fitted to the breath collection harness, so that a common gas mix was available to each line. Half of the lines collected samples into PVC yokes using a modified capillary system as commonly used in New Zealand (NZL), and half collected samples into stainless steel cylinders using a ball-bearing flow restrictor as used in Argentina (ARG), all within a 10-day time frame, either daily, across two consecutive 5-day periods or across one 10-day period (in duplicate). The NZL system had greater sampling success (97.3 vs. 79.5%) and yielded more consistent CH4 emission estimates than the ARG system. Emission estimates from NZL daily, NZL 5-day and NZL 10-day samplings

  16. Fiber-based solid phase microextraction using fused silica lined bottles to collect, store, and stabilize a multianalyte headspace gas sample for offline analyses.

    PubMed

    Harvey, Chris A; Carter, J Chance; Ertel, John R; Alviso, Cindy T; Chinn, Sarah C; Maxwell, Robert S

    2015-07-01

    We have developed a solid phase microextraction (SPME) sampling method using fused silica lined bottles (400 ml) to collect, store, and stabilize a headspace subsample from the source for subsequent offline, repetitive analyses of the gas using fiber-based SPME. The method enables long-term stability for repeated offline analysis of the organic species collected from the source headspace and retains all the advantages of fiber SPME sampling (e.g. rapid extraction, solvent free, simple and inexpensive) while providing additional advantages. Typically, the analytes collected on the SPME fiber must be desorbed and analyzed immediately to mitigate analyte loss or contamination. The new SPME sampling method, conducted offline using carboxen/polydimethylsiloxane (carboxen/PDMS - 85 μm) coated fibers, has been shown to be identical to in situ SPME sampling of a headspace acquired from an 80 component organic matrix with reproducibility demonstrated to be less than %RSD=7.0% for replicate samples measured over a 30-day period. In addition, repetitive samplings from one headspace aliquot are possible using one or more fibers and fiber types as well as quantitative options such as internal standard addition as demonstrated in a feasibility study using a benzene/toluene/xylene (BTX; 1 ppmv) certified gas standard, in which the SPME measurement precision (%RSD) was improved by a factor of 1.5-1.9 compared to the use of an external standard.

  17. The CUPID (Cultural and Psychosocial Influences on Disability) Study: Methods of Data Collection and Characteristics of Study Sample

    PubMed Central

    Coggon, David; Ntani, Georgia; Palmer, Keith T.; Felli, Vanda E.; Harari, Raul; Barrero, Lope H.; Felknor, Sarah A.; Gimeno, David; Cattrell, Anna; Serra, Consol; Bonzini, Matteo; Solidaki, Eleni; Merisalu, Eda; Habib, Rima R.; Sadeghian, Farideh; Kadir, Masood; Warnakulasuriya, Sudath S. P.; Matsudaira, Ko; Nyantumbu, Busisiwe; Sim, Malcolm R.; Harcombe, Helen; Cox, Ken; Marziale, Maria H.; Sarquis, Leila M.; Harari, Florencia; Freire, Rocio; Harari, Natalia; Monroy, Magda V.; Quintana, Leonardo A.; Rojas, Marianela; Salazar Vega, Eduardo J.; Harris, E. Clare; Vargas-Prada, Sergio; Martinez, J. Miguel; Delclos, George; Benavides, Fernando G.; Carugno, Michele; Ferrario, Marco M.; Pesatori, Angela C.; Chatzi, Leda; Bitsios, Panos; Kogevinas, Manolis; Oha, Kristel; Sirk, Tuuli; Sadeghian, Ali; Peiris-John, Roshini J.; Sathiakumar, Nalini; Wickremasinghe, A. Rajitha; Yoshimura, Noriko; Kielkowski, Danuta; Kelsall, Helen L.; Hoe, Victor C. W.; Urquhart, Donna M.; Derett, Sarah; McBride, David; Gray, Andrew

    2012-01-01

    Background The CUPID (Cultural and Psychosocial Influences on Disability) study was established to explore the hypothesis that common musculoskeletal disorders (MSDs) and associated disability are importantly influenced by culturally determined health beliefs and expectations. This paper describes the methods of data collection and various characteristics of the study sample. Methods/Principal Findings A standardised questionnaire covering musculoskeletal symptoms, disability and potential risk factors, was used to collect information from 47 samples of nurses, office workers, and other (mostly manual) workers in 18 countries from six continents. In addition, local investigators provided data on economic aspects of employment for each occupational group. Participation exceeded 80% in 33 of the 47 occupational groups, and after pre-specified exclusions, analysis was based on 12,426 subjects (92 to 1018 per occupational group). As expected, there was high usage of computer keyboards by office workers, while nurses had the highest prevalence of heavy manual lifting in all but one country. There was substantial heterogeneity between occupational groups in economic and psychosocial aspects of work; three- to five-fold variation in awareness of someone outside work with musculoskeletal pain; and more than ten-fold variation in the prevalence of adverse health beliefs about back and arm pain, and in awareness of terms such as “repetitive strain injury” (RSI). Conclusions/Significance The large differences in psychosocial risk factors (including knowledge and beliefs about MSDs) between occupational groups should allow the study hypothesis to be addressed effectively. PMID:22792189

  18. Volatile organic components of air samples collected from Vertical Launch Missile capsules. Summary report

    SciTech Connect

    Tappan, D.V.; Knight, D.R.; Heyder, E.; Weathersby, P.K.

    1988-09-27

    Gas chromatographic/mass spectroscopic analyses are presented for the volatile organic components found in air samples collected from the inboard vents from Vertical Launch System (VLS) missile capsules aboard a 688 class submarine. Similar analyses were also conducted for a sample of the ship's high pressure air used to fill the missile tubes. A wide variety of organics was detected in the air from the missile capsules; and while no unique components have yet been identified, a significant contribution has been shown to be made by pressure-ventilation of the VLS capsules into the submarine atmosphere which is already heavily laden with volatile organic compounds. The most apparent conclusion from these preliminary analyses is that the mixtures of organic components in the air within VLS missile capsules vary greatly from capsule to capsule (and probably from time to time). Many such samples need to be investigated to provide sufficient information to judge the seriousness of the possibility of venting toxic components into the submarine atmosphere during the maintenance or firing of VLS missiles.

  19. Guidance Regarding Sample Collection and Refinement of Fecal Flotation Exam for the Isolation of Aspiculuris tetraptera.

    PubMed

    Goodroe, Anna E; Baxter, Victoria K; Watson, Julie

    2016-01-01

    Aspiculuris tetraptera continues to be a problem in rodent vivaria, in part due to difficulties in parasite detection. Although PCR testing is highly sensitive, it is expensive and does not always provide immediate results. Consequently, many institutions rely on passive fecal flotation as a quick inhouse exam for diagnosing A. tetraptera infections. To increase the sensitivity of this test, we examined multiple parameters to determine the optimal test protocol. A 30-min soaking period prior to fecal flotation for 15 min allowed fecal pellets to soften and facilitated efficient egg isolation. We also evaluated the effect of time of day, sample size, age, sex, and housing status on egg isolation. No evidence of cyclical egg shedding was found, and although larger fecal sample sizes did not result in more eggs isolated, their use reduced the incidence of false-negative exams. The most eggs were isolated from 8- and 12-wk-old mice, and as mice aged, the number of eggs isolated declined. Overall, neither sex nor housing status influenced the number of eggs isolated. Finally, examination of multiple diagnostic tests (fecal flotation exam, direct examination of cecal and colonic contents, and fecal PCR) revealed that no single test was definitive, thus indicating that multiple tests might be required to successfully screen mice with low pinworm burdens. These findings provide guidance regarding sample selection, collection, and processing to efficiently detect A. tetraptera. PMID:27657708

  20. Analytical results from samples collected during coal-bed methane exploration drilling in Caldwell Parish, Louisiana

    USGS Publications Warehouse

    Warwick, Peter D.; Breland, F. Clayton; Hackley, Paul C.; Dulong, Frank T.; Nichols, Douglas J.; Karlsen, Alexander W.; Bustin, R. Marc; Barker, Charles E.; Willett, Jason C.; Trippi, Michael H.

    2006-01-01

    In 2001, and 2002, the U.S. Geological Survey (USGS) and the Louisiana Geological Survey (LGS), through a Cooperative Research and Development Agreement (CRADA) with Devon SFS Operating, Inc. (Devon), participated in an exploratory drilling and coring program for coal-bed methane in north-central Louisiana. The USGS and LGS collected 25 coal core and cuttings samples from two coal-bed methane test wells that were drilled in west-central Caldwell Parish, Louisiana. The purpose of this report is to provide the results of the analytical program conducted on the USGS/LGS samples. The data generated from this project are summarized in various topical sections that include: 1. molecular and isotopic data from coal gas samples; 2. results of low-temperature ashing and X-ray analysis; 3. palynological data; 4. down-hole temperature data; 5. detailed core descriptions and selected core photographs; 6. coal physical and chemical analytical data; 7. coal gas desorption results; 8. methane and carbon dioxide coal sorption data; 9. coal petrographic results; and 10. geophysical logs.

  1. Preparation of polyethylene sacks for collection of precipitation samples for chemical analysis

    USGS Publications Warehouse

    Schroder, L.J.; Bricker, A.W.

    1985-01-01

    Polyethylene sacks are used to collect precipitation samples. Washing polyethylene with acetone, hexane, methanol, or nitric acid can change the adsorptive characteristics of the polyethylene. In this study, simulated precipitation at pH 4.5 was in contact with the polyethylene sacks for 21 days; subsamples were removed for chemical analysis at 7, 14, and 21 days after intitial contact. Sacks washed with acetone adsorbed iron and lithium; sacks washed with hexane adsorbed barium, iron , and lithium; sacks washed with methanol adsorbed calcium and iron; and sacks washed with 0.30 N nitric acid adsorbed iron. Leaching the plastic sacks with 0.15 N nitric acid did not result in 100-percent recovery of any of the adsorbed metals. Washing polyethylene sacks with dilute nitric acid caused the pH of the simulated precipitation to be decreased by 0.2 pH unit after 1 week of contact with the polyethylene. The specific conductance increased by 10 microsiemens per centimeter. Contamination of precipitation samples by lead was determined to be about 0.1 microgram per liter from contact with precleaned polyethylene sacks. No measurable contamination of precipitation samples by zinc occurred. (USGS)

  2. Mobile on-site sample collection, preparation, and analysis in Iraq. Final report, January-April 1995

    SciTech Connect

    Swahn, I.D.; Brzezinski, J.H.

    1996-11-01

    The U.S. Army Edgewood Research, Development and Engineering Center has developed mobile on-site sample collection, preparation, and analysis equipment to collect environmental samples in highly contaminated areas. This equipment is being used by the United Nations Special Commission at the Baghdad Monitoring and Verification Center (BMVC), which provides long-term monitoring of dual-purpose chemical sites in Iraq, especially those with potential for chemical warfare (CW) production. A mobile laboratory was set-up in the BMVC to prepare and analyze samples collected throughout Iraq. Automatic air samplers were installed at various sites to collect vapor samples on absorption tubes that were analyzed using a gas chromatographic (GC) flame photometric detector (FPD). Mobile sample collection kits were used to collect solid, liquid, air, and wipe samples during challenge inspections. These samples were prepared using a sample preparation kit, which concentrates CW agent, breakdown products, and their precursors in complex matrices down to sub part per million levels for chemical analysis by a GC mass selective detector (MSD). This report describes the problems and solutions encountered with setting up a self-sufficient mobile analytical laboratory. Details of the various components associated with the laboratory and the collection kits are included.

  3. Temporal and spatial trends of chemical composition of wet deposition samples collected in Austria

    NASA Astrophysics Data System (ADS)

    Schreiner, Elisabeth; Kasper-Giebl, Anne; Lohninger, Hans

    2016-04-01

    Triggered by the occurrence of acid rain a sampling network for the collection of wet deposition samples was initiated in Austria in the early 1980s. Now the data set covers a time period of slightly more than 30 years for the stations being operable since the beginning. Sampling of rain water and snow was and is performed with Wet and Dry Only Samplers (WADOS) on a daily basis. Chemical analysis of rain water and snow samples comprised anions (chloride, nitrate, sulfate) and cations (sodium, ammonium, potassium, calcium and magnesium) as well as pH and electrical conductivity. Here we evaluate and discuss temporal trends of both, ion concentrations and wet deposition data for twelve sampling stations, which were operable for most of the observation period of 30 years. As expected concentrations and wet deposition loads of sulfate and acidity decreased significantly during the last three decades - which is also reflected by a strong decrease of sulfur emissions in Austria and neighboring countries. Regarding nitrate the decrease of concentrations and wet deposition loads is less pronounced. Again this is in accordance with changes in emission data. In case of ammonium even less stations showed a significant decrease of annual average concentrations and depositions. Reasons for that might be twofold. On one hand emissions of ammonia did not decrease as strongly as e.g. sulfur emissions. Furthermore local sources will be more dominant and can influence the year to year variability. Seasonality of ion concentrations and deposition loads were investigated using Fourier analysis. Sulfate, nitrate, ammonium, acidity and also precipitation amount showed characteristic seasonal patterns for most of the sites and for concentrations as well as deposition loads. However the maxima in ion concentrations and deposition loads were observed during different times of the year. Concentrations of basic cations and chloride, on the contrary, hardly showed any seasonality. However, as

  4. Plutonium in Colorado residents: results of autopsy bone samples collected during 1975-1979.

    PubMed

    Ibrahim, S A; Warren, G M; Whicker, F W; Efurd, D W

    2002-08-01

    Concentrations of (239,240)Pu and the 240Pu/239Pu atom ratios were measured in rib samples from 55 non-occupationally exposed Colorado residents. Samples were collected at autopsy during 1975-1979 under an earlier study intended to compare plutonium levels in liver and lung of people who lived at various proximities to the Rocky Flats Environmental Technology Site (RFETS) near Denver. Overall, median (239,240)Pu concentrations from rib samples were 100, 80, and 57 microBq g(-1) ash weight for area locations A, B, and C, respectively. Area A encompassed subjects who lived within 25 km of RFETS, area B was between 25 and 50 km from RFETS, and area C included all of Colorado outside 50 km from the site and east of the continental divide. The corresponding median plutonium skeletal burdens estimated for these area locations were 146, 93, and 71 mBq, respectively. A statistically significant difference was noted only between plutonium concentrations in male rib samples and their skeletal burdens from area A compared to area C. However, based on a regression analysis of all study subjects, distance from RFETS was not statistically correlated to plutonium rib concentrations or skeletal burdens in this sample. Overall, median 240Pu/239Pu atom ratios were 0.20, 0.18, and 0.17 for areas A, B, and C, respectively. Although higher (239,240)Pu concentrations and skeletal burdens were indicated in area A males than area C males, we cannot conclude that RFETS releases may have caused this difference. The decreasing trends in the 240Pu/239Pu ratios with distance from RFETS are contrary with such a conclusion and strongly indicate that the material was primarily global fallout rather than weapons-grade plutonium that was processed at RFETS. Furthermore, there are other plausible explanations for the differences observed between area A and C residents. These include a decreasing trend in global fallout from the Rocky Mountain foothills eastward, smoking history differences, sample

  5. Pre-Mission Input Requirements to Enable Successful Sample Collection by a Remote Field/EVA Team

    NASA Technical Reports Server (NTRS)

    Cohen, B. A.; Young, K. E.; Lim, D. S.

    2015-01-01

    objectives than samples collected in the absence of this premission information. We conducted three tests of this hypothesis. Our investigation was designed to document processes, tools and procedures for crew sampling of planetary targets. This is not meant to be a blind, controlled test of crew efficacy, but rather an effort to recognize the relevant variables that enter into sampling protocol and to develop recommendations for crew and backroom training in future endeavors. Methods: One of the primary FINESSE field deployment objectives was to collect impact melt rocks and impact melt-bearing breccias from a number of locations around the WCIS structure to enable high precision geochronology of the crater to be performed [1]. We conducted three tests at WCIS after two full days of team participation in field site activities, including using remote sensing data and geologic maps, hiking overland to become familiar with the terrain, and examining previously-collected samples from other islands. In addition, the team members shared their projects and techniques with the entire team. We chose our "crew members" as volunteers from the team, all of whom had had moderate training in geologic fieldwork and became familiar with the general field setting. The first two tests were short, focused tests of our hypothesis. Test A was to obtain hydrothermal vugs; Test B was to obtain impact melt and intrusive rock as well as the contact between the two to check for contact metamorphism and age differences. In both cases, the test director had prior knowledge of the site geology and had developed a study-specific objective for sampling prior to deployment. Prior to the field deployment, the crewmember was briefed on the sampling objective and the laboratory techniques that would be used on the samples. At the field sites (Fig. 2), the crewmember was given 30 minutes to survey a small section of outcrop (10-15 m) and acquire a suite of three samples. The crewmember talked through his

  6. The Consistency of Isotopologues of Ambient Atmospheric Nitric Acid in Passively Collected Samples

    NASA Astrophysics Data System (ADS)

    Bell, M. D.; Sickman, J. O.; Bytnerowicz, A.; Padgett, P.; Allen, E. B.

    2012-12-01

    Anthropogenic sources of nitrogen oxides have previously been shown to have distinctive isotopic signatures of oxygen and nitrogen. Nylon filters are currently used in passive sampling arrays to measure ambient atmospheric nitric acid concentrations and estimate deposition rates. This experiment measured the ability of nylon filters to consistently collect isotopologues of atmospheric nitric acid in the same ratios as they are present in the atmosphere. Samplers were deployed in continuous stirred tank reactors (CSTR) and at field sites across a nitrogen deposition gradient in Southern California. Filters were exposed over a four week period with individual filters being subjected to 1-4 week exposure times. Extracted nitric acid were measured for δ18O and δ15N ratios and compared for consistency based on length of exposure and amount of HNO3 collected. Filters within the CSTRs collected HNO3 at a consistent rate in both high and low concentration chambers. After two weeks of exposure, the mean δ18O values were within 0.5‰ of the δ18O of the source HNO3 solution. The mean of all weekly exposures were within 0.5‰ of the δ15N of the source solution, but after three weeks, the mean δ15N of adsorbed HNO3 was within 0.2‰. As the length of the exposure increased, the variability of measured delta values decreased for both elements. The field samplers collected HNO3 consistent with previously measured values along a deposition gradient. The mean δ18O at high deposition sites was 52.2‰ compared to 35.7‰ at the low deposition sites. Mean δ15N values were similar at all sites across the deposition gradient. Due to precipitation events occurring during the exposure period, the δ15N and δ18O of nitric acid were highly variable at all field sites. At single sites, changes in δ15N and δ18O were negatively correlated, consistent with two-sourcing mixing dynamics, but the slope of the regressions differed between high and low deposition sites. Anthropogenic

  7. Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure using a laser sensor

    DOEpatents

    Van Berkel, Gary J.; Kertesz, Vilmos

    2012-02-21

    A system and method utilizes distance-measuring equipment including a laser sensor for controlling the collection instrument-to-surface distance during a sample collection process for use, for example, with mass spectrometric detection. The laser sensor is arranged in a fixed positional relationship with the collection instrument, and a signal is generated by way of the laser sensor which corresponds to the actual distance between the laser sensor and the surface. The actual distance between the laser sensor and the surface is compared to a target distance between the laser sensor and the surface when the collection instrument is arranged at a desired distance from the surface for sample collecting purposes, and adjustments are made, if necessary, so that the actual distance approaches the target distance.

  8. Aspergillus, Penicillium and Talaromyces isolated from house dust samples collected around the world.

    PubMed

    Visagie, C M; Hirooka, Y; Tanney, J B; Whitfield, E; Mwange, K; Meijer, M; Amend, A S; Seifert, K A; Samson, R A

    2014-06-01

    As part of a worldwide survey of the indoor mycobiota, dust was collected from nine countries. Analyses of dust samples included the culture-dependent dilution-to-extinction method and the culture-independent 454-pyrosequencing. Of the 7 904 isolates, 2 717 isolates were identified as belonging to Aspergillus, Penicillium and Talaromyces. The aim of this study was to identify isolates to species level and describe the new species found. Secondly, we wanted to create a reliable reference sequence database to be used for next-generation sequencing projects. Isolates represented 59 Aspergillus species, including eight undescribed species, 49 Penicillium species of which seven were undescribed and 18 Talaromyces species including three described here as new. In total, 568 ITS barcodes were generated, and 391 β-tubulin and 507 calmodulin sequences, which serve as alternative identification markers. PMID:25492981

  9. Aspergillus, Penicillium and Talaromyces isolated from house dust samples collected around the world

    PubMed Central

    Visagie, C.M.; Hirooka, Y.; Tanney, J.B.; Whitfield, E.; Mwange, K.; Meijer, M.; Amend, A.S.; Seifert, K.A.; Samson, R.A.

    2014-01-01

    As part of a worldwide survey of the indoor mycobiota, dust was collected from nine countries. Analyses of dust samples included the culture-dependent dilution-to-extinction method and the culture-independent 454-pyrosequencing. Of the 7 904 isolates, 2 717 isolates were identified as belonging to Aspergillus, Penicillium and Talaromyces. The aim of this study was to identify isolates to species level and describe the new species found. Secondly, we wanted to create a reliable reference sequence database to be used for next-generation sequencing projects. Isolates represented 59 Aspergillus species, including eight undescribed species, 49 Penicillium species of which seven were undescribed and 18 Talaromyces species including three described here as new. In total, 568 ITS barcodes were generated, and 391 β-tubulin and 507 calmodulin sequences, which serve as alternative identification markers. PMID:25492981

  10. Aspergillus, Penicillium and Talaromyces isolated from house dust samples collected around the world.

    PubMed

    Visagie, C M; Hirooka, Y; Tanney, J B; Whitfield, E; Mwange, K; Meijer, M; Amend, A S; Seifert, K A; Samson, R A

    2014-06-01

    As part of a worldwide survey of the indoor mycobiota, dust was collected from nine countries. Analyses of dust samples included the culture-dependent dilution-to-extinction method and the culture-independent 454-pyrosequencing. Of the 7 904 isolates, 2 717 isolates were identified as belonging to Aspergillus, Penicillium and Talaromyces. The aim of this study was to identify isolates to species level and describe the new species found. Secondly, we wanted to create a reliable reference sequence database to be used for next-generation sequencing projects. Isolates represented 59 Aspergillus species, including eight undescribed species, 49 Penicillium species of which seven were undescribed and 18 Talaromyces species including three described here as new. In total, 568 ITS barcodes were generated, and 391 β-tubulin and 507 calmodulin sequences, which serve as alternative identification markers.

  11. Training in metabolomics research. I. Designing the experiment, collecting and extracting samples and generating metabolomics data.

    PubMed

    Barnes, S; Benton, H P; Casazza, K; Cooper, S J; Cui, X; Du, X; Engler, J A; Kabarowski, J H; Li, S; Pathmasiri, W; Prasain, J K; Renfrow, M B; Tiwari, H K

    2016-07-01

    Metabolomics is perhaps the most challenging of the -omics fields, given the complexity of an organism's metabolome and the rapid rate at which it changes. When one sets out to study metabolism there are numerous dynamic variables that can influence metabolism that must be considered. Recognizing the experimental challenges confronting researchers who undertake metabolism studies, workshops like the one at University of Alabama at Birmingham have been established to offer instructional guidance. A summary of the UAB course training materials is being published as a two-part Special Feature Tutorial. In this month's Part I the authors discuss details of good experimental design and sample collection and handling. In an upcoming Part II, the authors discuss in detail the various aspects of data analysis.

  12. Lessons Learned for Geologic Data Collection and Sampling: Insights from the Desert RATS 2010 Geologist Crewmembers

    NASA Technical Reports Server (NTRS)

    Hurtado, J. M., Jr.; Bleacher, J. E.; Rice, J.; Young, K.; Garry, W. B.; Eppler, D.

    2011-01-01

    Since 1997, Desert Research and Technology Studies (D-RATS) has conducted hardware and operations tests in the Arizona desert that advance human and robotic planetary exploration capabilities. D-RATS 2010 (8/31-9/13) simulated geologic traverses through a terrain of cinder cones, lava flows, and underlying sedimentary units using a pair of crewed rovers and extravehicular activities (EVAs) for geologic fieldwork. There were two sets of crews, each consisting of an engineer/commander and an experienced field geologist drawn from the academic community. A major objective of D-RATS was to examine the functions of a science support team, the roles of geologist crewmembers, and protocols, tools, and technologies needed for effective data collection and sample documentation. Solutions to these problems must consider how terrestrial field geology must be adapted to geologic fieldwork during EVAs

  13. A model for improving student confidence and experience in diagnostic sample collection and interpretation.

    PubMed

    Williams, Laurel E; Nettifee-Osborne, Julie A; Johnson, Jeffrey L

    2006-01-01

    Confidence and proficiency in diagnosing and treating a variety of diseases is of obvious importance to veterinary students. Traditional teaching methods relying on live-animal laboratories or teaching-hospital cases may not provide the breadth and depth of experience necessary to promote optimal development of confidence and skills. These settings also raise concerns about expense, about animal welfare when animals are used in teaching laboratories, and about the stress and potential risks associated with client-owned pets in the teaching hospital. A one-week course implemented in our veterinary curriculum provides the opportunity for students to develop self-assurance and experience in sample collection and interpretation skills in a realistic, clinical-model setting. This course provides students with significantly improved levels of confidence when performing procedures and interpreting results from a variety of procedures and helps prepare them to become clinicians entering the practice of veterinary medicine. PMID:16767653

  14. Iodide sorption and partitioning in solid, liquid and gas phases in soil samples collected from Japanese paddy fields.

    PubMed

    Ishikawa, Nao K; Uchida, Shigeo; Tagami, Keiko

    2011-07-01

    Sorption kinetics of iodide (I(-)), which is one of the major inorganic chemical forms of iodine in soil environments, were studied under four sets of experimental conditions characterised by temperature or biological activity. We compared partitioning ratios in solid, liquid and gas phases in soils as well as soil-soil solution distribution coefficients (K(d)s) at two different temperatures 4 and 23 °C, for 63 paddy soil samples collected throughout Japan. Interestingly, (125)I emission from soil was observed; the partitioning ratios in gas phase ranged from 0 to 27 % at 4 °C and from 0 to 42 % at 23 °C. In addition, the authors found that K(d) values at 23 °C had good correlation with pH though there was no correlation between K(d) values at 4 °C and pH because of the difference in biological activity.

  15. Evaluation of novel assays for the detection of human papilloma virus in self-collected samples for cervical cancer screening.

    PubMed

    Chen, Q; Du, H; Zhang, R; Zhao, J H; Hu, Q C; Wang, C; Wang, G X; Tang, J L; Wu, R F

    2016-01-01

    The aim of this study was to evaluate the performance of three new high-risk human papillomavirus (HPV) assays for primary cervical cancer screening, by using self-collected samples, and to identify an HPV assay that could overcome the major obstacles faced during large-scale population-based screening. Two hundred and ten women showing abnormal cervical cytology (and referred for a colposcopy) were recruited in this study. Self-collected samples obtained from all women were tested with the Cobas, Seq, and BioPerfectus Multiplex Real Time HPV assays; simultaneously, clinician-collected samples (from the same women) were tested with the gold-standard Cobas HPV assay. The results of all the assays were consistent. The sensitivity, positive predictive value, and negative predictive value for cervical intraepithelial neoplasia 2+ (CIN2+) and CIN3+ were comparable between the self-collected samples tested with the three new assays and the clinician-collected samples tested with the Cobas HPV assay (P > 0.05). The single-genotype HPV load per sample did not differ significantly between the self- and clinician-collected samples (P = 0.195). In conclusion, the results of this study demonstrated the applicability of the three new HPV assays for primary cervical cancer screening based on self-collection. PMID:27420961

  16. Gene Expression Analysis of the Irrigation Solution Samples Collected during Vitrectomy for Idiopathic Epiretinal Membrane

    PubMed Central

    Myojin, Sayaka; Yoshida, Shigeo; Takeda, Atsunobu; Murakami, Yusuke; Kawano, Yoichi; Oshima, Yuji; Ishibashi, Tatsuro; Sonoda, Koh-Hei

    2016-01-01

    Purpose The analysis of gene expression in idiopathic epiretinal membranes (iERMs) may help elucidate ERM formation and its pathology. Here, we conducted a case-control study, in order to determine the expression levels of cytokines and other genes in eyes with macular hole (MH) or iERM. Methods Twenty eyes, obtained from seven male and 13 female patients, were included in the study. The average age of the study subjects was 69.1 ± 7.67 years, and 15 eyes had iERM, while five eyes had MH. Irrigation solution samples were collected during vitrectomy, centrifuged, and the levels of cytokine and other mRNAs in the sediment were assessed using real-time PCR. The expression level of 11 cytokine genes, four transcription factor genes, two cytoskeletal genes, and genes encoding two extracellular matrix proteins in eyes with MH or iERM were determined and compared. Results The expression levels of interleukin 6 (IL6), tumor growth factor B2 (TGFB2), vascular endothelial growth factor A (VEGFA), chemokine C-X-C motif ligand 1 (CXCL1), v-rel avian reticuloendotheliosis viral oncogene homolog A (RELA), glial fibrillary acidic protein (GFAP), and tenascin C (TNC) were significantly higher in eyes with iERM than in eyes with MH. The expression of these genes was not associated with the preoperative visual acuity of the investigated patients. Conclusions The obtained results indicate that real-time PCR analysis of irrigation solution samples collected during vitrectomy can help assess the expression levels of several genes, and that iERM is associated with the expression of pro-inflammatory genes and the genes expressed during angiogenesis and wound healing process (IL6, TGFB2, VEGFA, CXCL1, RELA, GFAP, and TNC). PMID:27736918

  17. Training in metabolomics research. I. Designing the experiment, collecting and extracting samples and generating metabolomics data

    PubMed Central

    Barnes, Stephen; Benton, H. Paul; Casazza, Krista; Cooper, Sara J.; Cui, Xiangqin; Du, Xiuxia; Engler, Jeffrey; Kabarowski, Janusz H.; Li, Shuzhao; Pathmasiri, Wimal; Prasain, Jeevan K.; Renfrow, Matthew B.; Tiwari, Hemant K.

    2016-01-01

    The study of metabolism has had a long history. Metabolomics, a systems biology discipline representing analysis of known and unknown pathways of metabolism, has grown tremendously over the past 20 years. Because of its comprehensive nature, metabolomics requires careful consideration of the question(s) being asked, the scale needed to answer the question(s), collection and storage of the sample specimens, methods for extraction of the metabolites from biological matrices, the analytical method(s) to be employed and the quality control of the analyses, how collected data are correlated, the statistical methods to determine metabolites undergoing significant change, putative identification of metabolites and the use of stable isotopes to aid in verifying metabolite identity and establishing pathway connections and fluxes. The National Institutes of Health Common Fund Metabolomics Program was established in 2012 to stimulate interest in the approaches and technologies of metabolomics. To deliver one of the program’s goals, the University of Alabama at Birmingham has hosted an annual 4-day short course in metabolomics for faculty, postdoctoral fellows and graduate students from national and international institutions. This paper is the first part of a summary of the training materials presented in the course to be used as a resource for all those embarking on metabolomics research. PMID:27434804

  18. Training in metabolomics research. I. Designing the experiment, collecting and extracting samples and generating metabolomics data.

    PubMed

    Barnes, Stephen; Benton, H Paul; Casazza, Krista; Cooper, Sara J; Cui, Xiangqin; Du, Xiuxia; Engler, Jeffrey; Kabarowski, Janusz H; Li, Shuzhao; Pathmasiri, Wimal; Prasain, Jeevan K; Renfrow, Matthew B; Tiwari, Hemant K

    2016-07-01

    The study of metabolism has had a long history. Metabolomics, a systems biology discipline representing analysis of known and unknown pathways of metabolism, has grown tremendously over the past 20 years. Because of its comprehensive nature, metabolomics requires careful consideration of the question(s) being asked, the scale needed to answer the question(s), collection and storage of the sample specimens, methods for extraction of the metabolites from biological matrices, the analytical method(s) to be employed and the quality control of the analyses, how collected data are correlated, the statistical methods to determine metabolites undergoing significant change, putative identification of metabolites and the use of stable isotopes to aid in verifying metabolite identity and establishing pathway connections and fluxes. The National Institutes of Health Common Fund Metabolomics Program was established in 2012 to stimulate interest in the approaches and technologies of metabolomics. To deliver one of the program's goals, the University of Alabama at Birmingham has hosted an annual 4-day short course in metabolomics for faculty, postdoctoral fellows and graduate students from national and international institutions. This paper is the first part of a summary of the training materials presented in the course to be used as a resource for all those embarking on metabolomics research. The complete set of training materials including slide sets and videos can be viewed at http://www.uab.edu/proteomics/metabolomics/workshop/workshop_june_2015.php. Copyright © 2016 John Wiley & Sons, Ltd. PMID:27434804

  19. Chemical analyses of soil samples collected from the Sandia National Laboratories, New Mexico environs, 1993-2005.

    SciTech Connect

    Deola, Regina Anne; Oldewage, Hans D.; Herrera, Heidi; Miller, Mark Laverne

    2006-03-01

    From 1993 through 2005, the Environmental Management Department of Sandia National Laboratories in Albuquerque, New Mexico (SNL/NM), has collected soil and sediment samples at numerous locations on-site, on the perimeter, and off-site for the purpose of determining potential impacts to the environs from operations at the Laboratories. These samples were submitted to an analytical laboratory for metal-in-soil analyses. Intercomparisons of these results were then made to determine if there was any statistical difference between on-site, perimeter, and off-site samples, or if there were year-to-year increasing or decreasing trends which indicated that further investigation may be warranted. This work provided the SNL Environmental Management Department with a sound baseline data reference against which to assess potential current operational impacts or to compare future operational impacts. In addition, it demonstrates the commitment that the Laboratories have to go beyond mere compliance to achieve excellence in its operations. This data is presented in graphical format with narrative commentaries on particular items of interest.

  20. Chemical analyses of soil samples collected from the Sandia National Laboratories, Kauai Test Facility, HI, 1999-2007.

    SciTech Connect

    Miller, Mark Laverne

    2007-11-01

    In 1999, 2002, and 2007, the Environmental Programs and Assurance Department of Sandia National Laboratories (SNL) at the Kauai Test Facility (KTF), HI, has collected soil samples at numerous locations on-site, on the perimeter, and off-site for determining potential impacts to the environs from operations at KTF. These samples were submitted to an analytical laboratory for metal-in-soil analyses. Intercomparisons of these results were then made to determine if there was any statistical difference between on-site, perimeter, and off-site samples, or if there were increasing or decreasing trends that indicated that further investigation might be warranted. This work provided the SNL Environmental Programs and Assurance Department with a sound baseline data reference against which to compare future operational impacts. In addition, it demonstrates the commitment that the Laboratories have to go beyond mere compliance to achieve excellence in its operations. This data is presented in graphical format with narrative commentaries on particular items of interest.

  1. The cross-sectional GRAS sample: A comprehensive phenotypical data collection of schizophrenic patients

    PubMed Central

    2010-01-01

    Background Schizophrenia is the collective term for an exclusively clinically diagnosed, heterogeneous group of mental disorders with still obscure biological roots. Based on the assumption that valuable information about relevant genetic and environmental disease mechanisms can be obtained by association studies on patient cohorts of ≥ 1000 patients, if performed on detailed clinical datasets and quantifiable biological readouts, we generated a new schizophrenia data base, the GRAS (Göttingen Research Association for Schizophrenia) data collection. GRAS is the necessary ground to study genetic causes of the schizophrenic phenotype in a 'phenotype-based genetic association study' (PGAS). This approach is different from and complementary to the genome-wide association studies (GWAS) on schizophrenia. Methods For this purpose, 1085 patients were recruited between 2005 and 2010 by an invariable team of traveling investigators in a cross-sectional field study that comprised 23 German psychiatric hospitals. Additionally, chart records and discharge letters of all patients were collected. Results The corresponding dataset extracted and presented in form of an overview here, comprises biographic information, disease history, medication including side effects, and results of comprehensive cross-sectional psychopathological, neuropsychological, and neurological examinations. With >3000 data points per schizophrenic subject, this data base of living patients, who are also accessible for follow-up studies, provides a wide-ranging and standardized phenotype characterization of as yet unprecedented detail. Conclusions The GRAS data base will serve as prerequisite for PGAS, a novel approach to better understanding 'the schizophrenias' through exploring the contribution of genetic variation to the schizophrenic phenotypes. PMID:21067598

  2. Quality Sample Collection, Handling, and Preservation for an Effective Microbial Forensics Program

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The collection and preservation of microbial forensic evidence are paramount to effeceint and successful investigation and attribution. If evidence, when available, is not collected, degrades, or is contaminated during collection, handling, transport, or storage, the downstream characterization and...

  3. Specific activity and hazards of granite samples collected from the Eastern Desert of Egypt.

    PubMed

    Arafa, Wafaa

    2004-01-01

    Fifty granitic rock samples were collected from different plutons in the central part of the Eastern Desert of Egypt and were analyzed for specific concentrations of (238)U, (232)Th and (40)K radionuclei. The measurements were carried out using a high performance and stability Nomad Plus spectroscopy system attached to a 1.7 keV (FWHM) HPGe detector. The spectra were analyzed using the direct gamma counting comparison method as well as the traditional absolute efficiency curve method. The highest average value of (238)U concentration (1184 Bq kg(-1)) was observed at EI Misikat region whereas the highest average values of (40)K and (232)Th concentration (2301.8 and 162.5 Bq kg(-1) respectively), were detected at Gabal Homret Waggat area. The radium equivalent activity (Ra(eq)), the absorbed dose rate (D), the external hazard index (H(ex)) and the annual gonadal dose equivalent were also calculated and compared to the international recommended values. Radon exhalation rate from the rock samples were measured using the activated charcoal canister method. The average value of radon exhalation varies from 0.052 to 0.69 Bq m(-2) h(-1) and depends on the specific concentration of uranium.

  4. A microfluidic cigarette smoke collecting platform for simultaneous sample extraction and multiplex analysis.

    PubMed

    Hu, Shan-Wen; Xu, Bi-Yi; Qiao, Shu; Zhao, Ge; Xu, Jing-Juan; Chen, Hong-Yuan; Xie, Fu-Wei

    2016-04-01

    In this work, we report a novel microfluidic gas collecting platform aiming at simultaneous sample extraction and multiplex mass spectrometry (MS) analysis. An alveolar-mimicking elastic polydimethylsiloxane (PDMS) structures was designed to move dynamically driven by external pressure. The movement was well tuned both by its amplitude and rhythm following the natural process of human respiration. By integrating the alveolar units into arrays and assembling them to gas channels, a cyclic contraction/expansion system for gas inhale and exhale was successfully constructed. Upon equipping this system with a droplet array on the alveolar array surface, we were able to get information of inhaled smoke in a new strategy. Here, with cigarette smoke as an example, analysis of accumulation for target molecules during passive smoking is taken. Relationships between the breathing times, distances away from smokers and inhaled content of nicotine are clarified. Further, by applying different types of extraction solvent droplets on different locations of the droplet array, simultaneous extraction of nicotine, formaldehyde and caproic acid in sidestream smoke (SS) are realized. Since the extract droplets are spatially separated, they can be directly analyzed by MS which is fast and can rid us of all complex sample separation and purification steps. Combining all these merits, this small, cheap and portable platform might find wide application in inhaled air pollutant analysis both in and outdoors.

  5. Automated biowaste sampling system improved feces collection, mass measurement and sampling. [by use of a breadboard model

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Young, R.

    1974-01-01

    The capability of the basic automated Biowaste Sampling System (ABSS) hardware was extended and improved through the design, fabrication and test of breadboard hardware. A preliminary system design effort established the feasibility of integrating the breadboard concepts into the ABSS.

  6. Field guide for collecting and processing stream-water samples for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.

    1994-01-01

    The U.S. Geological Survey's National Water-Quality Assessment program includes extensive data- collection efforts to assess the quality of the Nations's streams. These studies require analyses of stream samples for major ions, nutrients, sediments, and organic contaminants. For the information to be comparable among studies in different parts of the Nation, consistent procedures specifically designed to produce uncontaminated samples for trace analysis in the laboratory are critical. This field guide describes the standard procedures for collecting and processing samples for major ions, nutrients, organic contaminants, sediment, and field analyses of conductivity, pH, alkalinity, and dissolved oxygen. Samples are collected and processed using modified and newly designed equipment made of Teflon to avoid contamination, including nonmetallic samplers (D-77 and DH-81) and a Teflon sample splitter. Field solid-phase extraction procedures developed to process samples for organic constituent analyses produce an extracted sample with stabilized compounds for more accurate results. Improvements to standard operational procedures include the use of processing chambers and capsule filtering systems. A modified collecting and processing procedure for organic carbon is designed to avoid contamination from equipment cleaned with methanol. Quality assurance is maintained by strict collecting and processing procedures, replicate sampling, equipment blank samples, and a rigid cleaning procedure using detergent, hydrochloric acid, and methanol.

  7. 9 CFR 147.12 - Procedures for collection, isolation, and identification of Salmonella from environmental samples...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... each sample with a sterile tongue depressor or similar uncontaminated instrument. The samples shall... with a sterile tongue depressor or similar uncontaminated instrument. The samples should vary in...

  8. Location and Age Database for Selected Foraminifer Samples Collected by Exxon Petroleum Geologists in California

    USGS Publications Warehouse

    Brabb, Earl E.; Parker, John M.

    2003-01-01

    Most of the geologic maps published for central California before 1960 were made without the benefit of age determinations from microfossils. The ages of Cretaceous and Tertiary rocks in the mostly poorly exposed and structurally complex sedimentary rocks represented in the Coast Ranges are critical in determining stratigraphic succession or lack of it, and in determining whether the juxtaposition of similar appearing but different age formations means a fault is present. Since the 1930’s, at least, oil company geologists have used microfossils to assist them in geologic mapping and in determining the environments of deposition of the sediment containing the microfossils. This information has been so confidential that some companies even coded the names of foraminifers to prevent disclosure. In the past 20 years, however, the attitude of petroleum companies about this information has changed, and many of the formerly confidential materials and reports are now available. We report here on 1,964 Exxon foraminifer samples mostly from surface localities in the San Francisco Bay region, and elsewhere in California. Most but not all the samples were plotted on U. S. Geological Survey (USGS) 7.5’ topographic maps or on obsolete USGS 15’ maps. The information from the slides can be used to update geologic maps prepared without the benefit of microfossil data, to analyze the depth and temperature of ocean water covering parts of California during the Mesozoic and Cenozoic Eras, and for solving nomenclature and other scientific problems. A similar report on more than 30,000 slides for surface samples collected by Chevron geologists has been released (Brabb and Parker, 2003), and another report provides information on slides for more than 2000 oil test wells in Northern California (Brabb, Powell, and Brocher, 2001).

  9. Antibiotic resistance among bacteria isolated from seawater and penguin fecal samples collected near Palmer Station, Antarctica.

    PubMed

    Miller, Robert V; Gammon, Katharine; Day, Martin J

    2009-01-01

    Antibiotic resistance in aquatic bacteria has increased steadily as a consequence of the widespread use of antibiotics, but practice and international treaty should have limited antibiotic contamination in Antarctica. We estimated antibiotic resistance in microorganisms isolated from the Antarctic marine waters and a penguin rookery, for 2 reasons: (i) as a measure of human impact and (ii) as a potential "snapshot" of the preantibiotic world. Samples were taken at 4 established sampling sites near Palmer Station, which is situated at the southern end of the Palmer Archipelago (64 degrees 10'S, 61 degrees 50'W). Sites were chosen to provide different potentials for human contamination. Forty 50 mL samples of seawater were collected and colony-forming units (CFU)/mL were determined at 6 and 20 degrees C. For this study, presumed psychrophiles (growth at 6 degrees C) were assumed to be native to Antarctic waters, whereas presumed mesophiles (growth at 20 degrees C but not at 6 degrees C) were taken to represent introduced organisms. The 20-6 degrees C CFU/mL ratio was used as a measure of the relative impact to the ecosystem of presumably introduced organisms. This ratio was highest at the site nearest to Palmer Station and decreased with distance from it, suggesting that human presence has impacted the natural microbial flora of the site. The frequency of resistance to 5 common antibiotics was determined in each group of isolates. Overall drug resistance was higher among the presumed mesophiles than the presumed psychrophiles and increased with proximity to Palmer Station, with the presumed mesophiles showing higher frequencies of single and multiple drug resistance than the psychrophile population. The frequency of multidrug resistance followed the same pattern. It appears that multidrug resistance is low among native Antarctic bacteria but is increased by human habitation.

  10. {sup 222}Rn in water: A comparison of two sample collection methods and two sample transport methods, and the determination of temporal variation in North Carolina ground water

    SciTech Connect

    Hightower, J.H. III

    1994-12-31

    Objectives of this field experiment were: (1) determine whether there was a statistically significant difference between the radon concentrations of samples collected by EPA`s standard method, using a syringe, and an alternative, slow-flow method; (2) determine whether there was a statistically significant difference between the measured radon concentrations of samples mailed vs samples not mailed; and (3) determine whether there was a temporal variation of water radon concentration over a 7-month period. The field experiment was conducted at 9 sites, 5 private wells, and 4 public wells, at various locations in North Carolina. Results showed that a syringe is not necessary for sample collection, there was generally no significant radon loss due to mailing samples, and there was statistically significant evidence of temporal variations in water radon concentrations.

  11. Analyses of water, core material, and elutriate samples collected near Sicily Island, Louisiana (Sicily Island area levee project)

    USGS Publications Warehouse

    Demcheck, Dennis K.; Dupuy, Alton J.

    1980-01-01

    Samples consisting of composited core material were collected from five areas by the U.S. Army Corps of Engineers and analyzed by the U.S. Geological Survey to provide data on the impact of proposed channel excavation and levee construction in the Sicily Island area, Louisiana. Samples of receiving water from the five areas, selected to represent the water that will contact the proposed dredged material of the levee fill material, also were collected. Chemical and physical analyses were performed on samples of core material and native water and on elutriate samples of specific core material-receiving water mixtures. The results of these analyses are presented without interpretation. (USGS)

  12. Geochemical results from stream-water and stream-sediment samples collected in Colorado and New Mexico

    USGS Publications Warehouse

    Hageman, Philip L.; Todd, Andrew S.; Smith, Kathleen S.; DeWitt, Ed; Zeigler, Mathew P.

    2013-01-01

    Scientists from the U.S. Geological Survey are studying the relationship between watershed lithology and stream-water chemistry. As part of this effort, 60 stream-water samples and 43 corresponding stream-sediment samples were collected in 2010 and 2011 from locations in Colorado and New Mexico. Sample sites were selected from small to midsize watersheds composed of a high percentage of one rock type or geologic unit. Stream-water and stream-sediment samples were collected, processed, preserved, and analyzed in a consistent manner. This report releases geochemical data for this phase of the study.

  13. Variation in aluminum, iron, and particle concentrations in oxic ground-water samples collected by use of tangential-flow ultrafiltration with low-flow sampling

    USGS Publications Warehouse

    Szabo, Z.; Oden, J.H.; Gibs, J.; Rice, D.E.; Ding, Y.; ,

    2001-01-01

    Particulates that move with ground water and those that are artificially mobilized during well purging could be incorporated into water samples during collection and could cause trace-element concentrations to vary in unfiltered samples, and possibly in filtered samples (typically 0.45-um (micron) pore size) as well, depending on the particle-size fractions present. Therefore, measured concentrations may not be representative of those in the aquifer. Ground water may contain particles of various sizes and shapes that are broadly classified as colloids, which do not settle from water, and particulates, which do. In order to investigate variations in trace-element concentrations in ground-water samples as a function of particle concentrations and particle-size fractions, the U.S. Geological Survey, in cooperation with the U.S. Air Force, collected samples from five wells completed in the unconfined, oxic Kirkwood-Cohansey aquifer system of the New Jersey Coastal Plain. Samples were collected by purging with a portable pump at low flow (0.2-0.5 liters per minute and minimal drawdown, ideally less than 0.5 foot). Unfiltered samples were collected in the following sequence: (1) within the first few minutes of pumping, (2) after initial turbidity declined and about one to two casing volumes of water had been purged, and (3) after turbidity values had stabilized at less than 1 to 5 Nephelometric Turbidity Units. Filtered samples were split concurrently through (1) a 0.45-um pore size capsule filter, (2) a 0.45-um pore size capsule filter and a 0.0029-um pore size tangential-flow filter in sequence, and (3), in selected cases, a 0.45-um and a 0.05-um pore size capsule filter in sequence. Filtered samples were collected concurrently with the unfiltered sample that was collected when turbidity values stabilized. Quality-assurance samples consisted of sequential duplicates (about 25 percent) and equipment blanks. Concentrations of particles were determined by light scattering

  14. Variation in aluminum, iron, and particle concentrations in oxic groundwater samples collected by use of tangential-flow ultrafiltration with low-flow sampling

    NASA Astrophysics Data System (ADS)

    Szabo, Zoltan; Oden, Jeannette H.; Gibs, Jacob; Rice, Donald E.; Ding, Yuan

    2002-02-01

    Particulates that move with ground water and those that are artificially mobilized during well purging could be incorporated into water samples during collection and could cause trace-element concentrations to vary in unfiltered samples, and possibly in filtered samples (typically 0.45-um (micron) pore size) as well, depending on the particle-size fractions present. Therefore, measured concentrations may not be representative of those in the aquifer. Ground water may contain particles of various sizes and shapes that are broadly classified as colloids, which do not settle from water, and particulates, which do. In order to investigate variations in trace-element concentrations in ground-water samples as a function of particle concentrations and particle-size fractions, the U.S. Geological Survey, in cooperation with the U.S. Air Force, collected samples from five wells completed in the unconfined, oxic Kirkwood-Cohansey aquifer system of the New Jersey Coastal Plain. Samples were collected by purging with a portable pump at low flow (0.2-0.5 liters per minute and minimal drawdown, ideally less than 0.5 foot). Unfiltered samples were collected in the following sequence: (1) within the first few minutes of pumping, (2) after initial turbidity declined and about one to two casing volumes of water had been purged, and (3) after turbidity values had stabilized at less than 1 to 5 Nephelometric Turbidity Units. Filtered samples were split concurrently through (1) a 0.45-um pore size capsule filter, (2) a 0.45-um pore size capsule filter and a 0.0029-um pore size tangential-flow filter in sequence, and (3), in selected cases, a 0.45-um and a 0.05-um pore size capsule filter in sequence. Filtered samples were collected concurrently with the unfiltered sample that was collected when turbidity values stabilized. Quality-assurance samples consisted of sequential duplicates (about 25 percent) and equipment blanks. Concentrations of particles were determined by light scattering.

  15. Effects on animal wellbeing and sample quality of 2 techniques for collecting blood from the facial vein of mice.

    PubMed

    Francisco, Cassie C; Howarth, Gordon S; Whittaker, Alexandra L

    2015-01-01

    When sampling blood from mice, several different techniques can be used, with retroorbital sinus sampling traditionally being the most common. Given the severe tissue trauma caused by retroorbital sampling, alternative methods such as the facial vein route have been developed. The aim of this study was to evaluate 2 techniques for facial vein bleeding in conscious mice to ascertain whether differences in clinical outcomes, practicability of sample collection, and hematologic parameters were apparent. Blood samples were obtained from the facial vein of 40 BALB/c mice by using either a 21-gauge needle or a lancet. Subsequently, the protocol was repeated with isoflurane-anesthetized mice sampled by using the lancet method (n = 20). Behavior immediately after sampling was observed, and sample quantity, sampling time, and time until bleeding ceased were measured. Clinical pathology data and hematoma diameter at necropsy were analyzed also. The mean sample quantity collected (approximately 0.2 mL) was comparable among methods, but sampling was much more rapid when mice were anesthetized by using isoflurane. The only other noteworthy finding was a significantly reduced number of platelets in samples from anesthetized mice. Adverse, ongoing clinical signs were rare regardless of the method used. The results revealed no significant differences in welfare implications or blood sample quality among the methods or between conscious and anesthetized mice. Therefore, any of the methods we evaluated for obtaining blood samples from the facial vein are appropriate for use in research studies.

  16. Effects on Animal Wellbeing and Sample Quality of 2 Techniques for Collecting Blood from the Facial Vein of Mice

    PubMed Central

    Francisco, Cassie C; Howarth, Gordon S; Whittaker, Alexandra L

    2015-01-01

    When sampling blood from mice, several different techniques can be used, with retroorbital sinus sampling traditionally being the most common. Given the severe tissue trauma caused by retroorbital sampling, alternative methods such as the facial vein route have been developed. The aim of this study was to evaluate 2 techniques for facial vein bleeding in conscious mice to ascertain whether differences in clinical outcomes, practicability of sample collection, and hematologic parameters were apparent. Blood samples were obtained from the facial vein of 40 BALB/c mice by using either a 21-gauge needle or a lancet. Subsequently, the protocol was repeated with isoflurane-anesthetized mice sampled by using the lancet method (n = 20). Behavior immediately after sampling was observed, and sample quantity, sampling time, and time until bleeding ceased were measured. Clinical pathology data and hematoma diameter at necropsy were analyzed also. The mean sample quantity collected (approximately 0.2 mL) was comparable among methods, but sampling was much more rapid when mice were anesthetized by using isoflurane. The only other noteworthy finding was a significantly reduced number of platelets in samples from anesthetized mice. Adverse, ongoing clinical signs were rare regardless of the method used. The results revealed no significant differences in welfare implications or blood sample quality among the methods or between conscious and anesthetized mice. Therefore, any of the methods we evaluated for obtaining blood samples from the facial vein are appropriate for use in research studies. PMID:25651095

  17. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF FOOD PREPARATION SURFACE WIPE SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.17)

    EPA Science Inventory

    This SOP describes the method for collection of the food preparation surface wipe samples for the measurement of persistent organic pollutants (POP). This method uses a wipe to collect POP residues from a surface where a study participant prepares food the most often (i.e., kitch...

  18. Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography Electrospray Ionization Mass Spectrometry

    SciTech Connect

    Ovchinnikova, Olga S; Kertesz, Vilmos; Van Berkel, Gary J

    2011-01-01

    This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection method for surface sampling and ionization with subsequent mass spectral analysis. A commercially available autosampler was adapted to produce a liquid droplet at the end of the syringe injection needle while in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collection was followed by either flow injection or a high performance liquid chromatography (HPLC) separation of the extracted components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the analytical utility of this coupling, thin films of a commercial ink sample containing rhodamine 6G and of mixed isobaric rhodamine B and 6G dyes on glass microscope slides were analyzed. The flow injection and HPLC/ESI-MS analysis revealed successful laser ablation, capture and, with HPLC, the separation of the two compounds. The ablated circular area was about 70 m in diameter for these experiments. The spatial sampling resolution afforded by the laser ablation, as well as the ability to use sample processing methods like HPLC between the sample collection and ionization steps, makes this combined surface sampling/ionization technique a highly versatile analytical tool.

  19. New Staphylinidae (Coleoptera) records with new collection data from New Brunswick and an addition to the fauna of Quebec: Staphylininae

    PubMed Central

    Webster, Reginald P.; Smetana, Aleš; Sweeney, Jon D.; DeMerchant, Ian

    2012-01-01

    Abstract Forty-four species of Staphylininae are newly reported from New Brunswick, bringing the total number of species known from the province to 126. Quedius criddlei (Casey) is reported for the first time from Quebec. Bisnius cephalotes (Gravenhorst) is removed from the faunal list of New Brunswick due to a lack of supporting voucher specimens. Additional locality data are presented for seven species either recently recorded from the province or with few previous records and little habitat data. We provide the first documented records of Atrecus americanus (Casey), Quedius erythrogaster Mannerheim, Quedius labradorensis labradorensis Smetana, Quedius plagiatus (Mannerheim), and Neobisnius terminalis (LeConte) from New Brunswick. Collection and habitat data are presented and discussed for all species. PMID:22577325

  20. Dynamic simulation tools for the analysis and optimization of novel collection, filtration and sample preparation systems

    SciTech Connect

    Clague, D; Weisgraber, T; Rockway, J; McBride, K

    2006-02-12

    The focus of research effort described here is to develop novel simulation tools to address design and optimization needs in the general class of problems that involve species and fluid (liquid and gas phases) transport through sieving media. This was primarily motivated by the heightened attention on Chem/Bio early detection systems, which among other needs, have a need for high efficiency filtration, collection and sample preparation systems. Hence, the said goal was to develop the computational analysis tools necessary to optimize these critical operations. This new capability is designed to characterize system efficiencies based on the details of the microstructure and environmental effects. To accomplish this, new lattice Boltzmann simulation capabilities where developed to include detailed microstructure descriptions, the relevant surface forces that mediate species capture and release, and temperature effects for both liquid and gas phase systems. While developing the capability, actual demonstration and model systems (and subsystems) of national and programmatic interest were targeted to demonstrate the capability. As a result, where possible, experimental verification of the computational capability was performed either directly using Digital Particle Image Velocimetry or published results.

  1. Radiometric assessment of natural radioactivity levels of agricultural soil samples collected in Dakahlia, Egypt.

    PubMed

    Issa, Shams A M

    2013-01-01

    Determination of the natural radioactivity has been carried out, by using a gamma-ray spectrometry [NaI (Tl) 3″ × 3″] system, in surface soil samples collected from various locations in Dakahlia governorate, Egypt. These locations form the agriculturally important regions of Egypt. The study area has many industries such as chemical, paper, organic fertilisers and construction materials, and the soils of the study region are used as a construction material. Therefore, it becomes necessary to study the natural radioactivity levels in soil to assess the dose for the population in order to know the health risks. The activity concentrations of (226)Ra, (232)Th and (40)K in the soil ranged from 5.7 ± 0.3 to 140 ± 7, from 9.0 ± 0.4 to 139 ± 7 and from 22 ± 1 to 319 ± 16 Bq kg(-1), respectively. The absorbed dose rate, annual effective dose rate, radium equivalent (Req), excess lifetime cancer risk, hazard indices (Hex and Hin) and annual gonadal dose equivalent, which resulted from the natural radionuclides in the soil were calculated.

  2. Collection and processing of plant, animal and soil samples from Bikini, Enewetak and Rongelap Atolls

    SciTech Connect

    Stuart, M.L.

    1995-09-01

    The United States used the Marshall Islands for its nuclear weapons program testing site from 1946 to 1958. The BRAVO test was detonated at Bikini Atoll on March 1, 1954. Due to shifting wind conditions at the time of the nuclear detonation, many of the surrounding Atolls became contaminated with fallout (radionuclides carried by the wind currents). Lawrence Livermore National Laboratory`s (LLNL) Marshall Islands Project has been responsible for the collecting, processing, and analyzing of food crops, vegetation, soil, water, animals, and marine species to characterize the radionuclides in the environment, and to estimate dose at atolls that may have been contaminated. Tropical agriculture experiments reducing the uptake of {sup 137}Cs have been conducted on Bikini Atoll. The Marshall Islands field team and laboratory processing team play an important role in the overall scheme of the Marshall Islands Dose Assessment and Radioecology Project. This report gives a general description of the Marshall Islands field sampling and laboratory processing procedures currently used by our staff.

  3. Distribution of vibrio species in shellfish and water samples collected from the atlantic coastline of south-east Nigeria.

    PubMed

    Eyisi, Onyedikachukwu A L; Nwodo, Uchechukwu U; Iroegbu, Christian U

    2013-09-01

    Crayfish, lobster, and sea-water samples collected from five fishing islands on the Atlantic coast-Bight of Biafra (Bonny)-belonging to Ibaka Local Government Area of Akwa-Ibom State of Nigeria were bacteriologically evaluated on thiosulphate citrate bile-salt sucrose (TCBS) agar for Vibrio load and pathotypes. Mean log10 Vibrio counts of 7.64+/-2.78 cfu/g (in crayfish), 5.07+/-3.21 cfu/g (in lobster), and 3.06+/-2.27 cfu/mL (in sea-water) were obtained in rainy season (June-July) while counts in the dry season (November-December) were 6.25+/-1.93 cfu/g, 5.99+/-1.54 cfu/g, and 3.84+/-1.78 cfu/mL respectively. The physicochemical measurements (temperature, pH, and total dissolved solutes) of the sea-water did not vary significantly in the two seasons across all five islands. Vibrio species isolated were Vibrio cholerae (both O1 and non-O1 serotypes), V parahaemolyticus, V vulnificus, V mimicus, and V fluvialis. Both Ogawa and Inaba subtypes of V cholerae O1 serotype were found. In addition, the Hikojima subtype, which had not been previously reported in the region, was isolated in two samples. The results show that these Vibrio species are endemic in the area.

  4. Estimation of a partially linear additive model for data from an outcome-dependent sampling design with a continuous outcome.

    PubMed

    Tan, Ziwen; Qin, Guoyou; Zhou, Haibo

    2016-10-01

    Outcome-dependent sampling (ODS) designs have been well recognized as a cost-effective way to enhance study efficiency in both statistical literature and biomedical and epidemiologic studies. A partially linear additive model (PLAM) is widely applied in real problems because it allows for a flexible specification of the dependence of the response on some covariates in a linear fashion and other covariates in a nonlinear non-parametric fashion. Motivated by an epidemiological study investigating the effect of prenatal polychlorinated biphenyls exposure on children's intelligence quotient (IQ) at age 7 years, we propose a PLAM in this article to investigate a more flexible non-parametric inference on the relationships among the response and covariates under the ODS scheme. We propose the estimation method and establish the asymptotic properties of the proposed estimator. Simulation studies are conducted to show the improved efficiency of the proposed ODS estimator for PLAM compared with that from a traditional simple random sampling design with the same sample size. The data of the above-mentioned study is analyzed to illustrate the proposed method.

  5. Estimation of a partially linear additive model for data from an outcome-dependent sampling design with a continuous outcome.

    PubMed

    Tan, Ziwen; Qin, Guoyou; Zhou, Haibo

    2016-10-01

    Outcome-dependent sampling (ODS) designs have been well recognized as a cost-effective way to enhance study efficiency in both statistical literature and biomedical and epidemiologic studies. A partially linear additive model (PLAM) is widely applied in real problems because it allows for a flexible specification of the dependence of the response on some covariates in a linear fashion and other covariates in a nonlinear non-parametric fashion. Motivated by an epidemiological study investigating the effect of prenatal polychlorinated biphenyls exposure on children's intelligence quotient (IQ) at age 7 years, we propose a PLAM in this article to investigate a more flexible non-parametric inference on the relationships among the response and covariates under the ODS scheme. We propose the estimation method and establish the asymptotic properties of the proposed estimator. Simulation studies are conducted to show the improved efficiency of the proposed ODS estimator for PLAM compared with that from a traditional simple random sampling design with the same sample size. The data of the above-mentioned study is analyzed to illustrate the proposed method. PMID:27006375

  6. Airborne detection and quantification of swine influenza a virus in air samples collected inside, outside and downwind from swine barns.

    PubMed

    Corzo, Cesar A; Culhane, Marie; Dee, Scott; Morrison, Robert B; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m³ of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m³ of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m³. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions.

  7. Airborne Detection and Quantification of Swine Influenza A Virus in Air Samples Collected Inside, Outside and Downwind from Swine Barns

    PubMed Central

    Corzo, Cesar A.; Culhane, Marie; Dee, Scott; Morrison, Robert B.; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m3 of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m3 of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m3. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions. PMID:23951164

  8. Impact of collection container material and holding times on sample integrity for mercury and methylmercury in water

    SciTech Connect

    Riscassi, Ami L; Miller, Carrie L; Brooks, Scott C

    2014-01-01

    Mercury (Hg) and methylmercury (MeHg) concentrations in streamwater can vary on short timescales (hourly or less) during storm flow and on a diel cycle; the frequency and timing of sampling required to accurately characterize these dynamics may be difficult to accomplish manually. Automated sampling can assist in sample collection; however use has been limited for Hg and MeHg analysis due to stability concerns of trace concentrations during extended storage times. We examined the viability of using automated samplers with disposable low-density polyethylene (LDPE) sample bags to collect industrially contaminated streamwater for unfiltered and filtered Hg and MeHg analysis. Specifically we investigated the effect of holding times ranging from hours to days on streamwater collected during baseflow and storm flow. Unfiltered and filtered Hg and MeHg concentrations decreased with increases in time prior to sample processing; holding times of 24 hours or less resulted in concentration changes (mean 11 7% different) similar to variability in duplicates collected manually during analogous field conditions (mean 7 10% different). Comparisons of samples collected with manual and automated techniques throughout a year for a wide range of stream conditions were also found to be similar to differences observed between duplicate grab samples. These results demonstrate automated sampling into LDPE bags with holding times of 24 hours or less can be effectively used to collect streamwater for Hg and MeHg analysis, and encourage the testing of these materials and methods for implementation in other aqueous systems where high-frequency sampling is warranted.

  9. Results of chemical and stable isotopic analyses of water samples collected in the Patagonia Mountains, southern Arizona

    USGS Publications Warehouse

    Wanty, Richard B.; Shanks, Wayne C.; Lamothe, Paul; Meier, A.L.; Lichte, Fred; Briggs, Paul H.; Berger, Byron R.

    2001-01-01

    Water samples were collected in the Patagonia Mountains in February, 1997. Most of the samples were collected from portals of abandoned mines, or from stream drainages immediately downstream from abandoned mines. Most of the samples have low pH ( 1000 mg/L). Anion composition of the water samples is dominated by sulfate, while cation compositions range from calcium-dominated to mixed calcium-magnesium or calcium-sodium-dominated waters. Metals such as iron, manganese, copper, zinc, and aluminum contribute a significant portion (>10%) of the cation content to the water samples. Because of the low pH?s, protons contribute up to several percent of the cation character of the waters in some of the samples. The data are presented in tabular and graphical formats, with descriptions of data quality and brief descriptions of results.

  10. (Collection of North Pacific Ocean surface seawater samples from a container ship): Foreign trip report, January 24--March 4, 1989

    SciTech Connect

    Goddard, J.G.

    1989-03-16

    This trip was a continuation of the sampling program undertaken during 1984--1985 to study the seasonal and regional variability of CO/sub 2/ chemistry in high-latitude deep water formation areas of the North Pacific. The work is conducted by Columbia University (Dr. Taro Takahashi, Principal Investigator) for the Department of Energy's Energy Systems Program managed by Oak Ridge National Laboratory. Aboard the President Eisenhower, we collected surface seawater samples at forty-two stations along the route from Oakland, California, to Keelung, Taiwan, via Guam. On the return trip, samples were collected from thirty-nine stations during transit from Kaohsiung, Taiwan, to Los Angeles, California.

  11. (Collection of North Pacific Ocean surface seawater samples for chemical analysis): Foreign trip report, January 26--February 27, 1988

    SciTech Connect

    Goddard, J.G.

    1988-03-04

    This trip was a continuation of the sampling program undertaken during 1984--1985 to study the seasonal and regional variability of CO/sub 2/ chemistry in high latitude deep water formation areas of the North Pacific. The work is conducted by Columbia University (Dr. Taro Takahashi, Principal Investigator) for the Department of Energy's Energy Systems Program managed by Oak Ridge National Laboratory. Aboard the PRESIDENT ARTHUR, surface seawater samples were collected at forty-one stations along the route from Oakland, California, to Keeling, Taiwan, via Guam. On the return trip, samples were collected from thirty-seven stations during transit from Keelung to Los Angeles, California.

  12. Waste tank vapor project: Vapor space characterization of waste tank 241-BY-104: Results from samples collected on June 24, 1994

    SciTech Connect

    Clauss, T.W.; Ligotke, M.W.; McVeety, B.D.; Pool, K.H.; Lucke, R.B.; Fruchter, J.S.; Goheen, S.C.

    1994-11-01

    This report describes results of the analyses of tank-headspace samples taken from Hanford waste Tank 241-BY-104 (referred to as Tank BY-104) on June 24, 1994. The Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze inorganic and organic samples collected from the tank headspace. The sample job was designated S4019 and was performed by WHC on June 24, 1994 using the vapor sampling system (VSS). The results of the analyses are expected to be used in the determination of safety and toxicological issues related to the tank-headspace gas as described in the WHC report entitled Data Quality Objectives for Generic In-Tank Health and Safety Vapor Issue Resolution, WHC-SD-WM-DQO-002, Rev. 0. Sampling devices, including 16 sorbent trains (for inorganic analyses), and 5 SUMMA{trademark} canisters (for organic analyses), were supplied to the WHC sampling staff on June 20, 1994. Samples were taken (by WHC) on June 24. The samples were returned from the field on June 27. The inorganic samples delivered to PNL on chain-of-custody (COC) 006893 included 16 sorbent trains as described in Tables 2.2, 2.3, and 2.4. Additional inorganic blank spikes were obtained from related sample jobs. SUMMA{trademark} samples delivered to PNL on COC 006896 included one ambient air sample, one ambient-air sample through the sampling system, and three tank-headspace SUMMA{trademark} canister samples. The samples were inspected upon delivery to the 326/23B laboratory and logged into PNL laboratory record book 55408. Custody of the sorbent trains was transferred to PNL personnel performing the inorganic analysis and stored at refrigerated ({le}10{degrees}C) temperature until the time of analysis. Access to the 326/23B laboratory is limited to PNL personnel working on the waste-tank safety program.

  13. Levels of PCDD/Fs in local and non-local food samples collected from a highly polluted area in Turkey.

    PubMed

    Aslan, Seda; Kemal Korucu, M; Karademir, Aykan; Durmusoglu, Ertan

    2010-08-01

    A sampling and analysis program were conducted to determine the PCDD/F levels in various food samples collected in Kocaeli, one of the highly polluted areas in Turkey. Several food samples including animal (egg, chicken, meat and cow's milk) and plant (fruits, leafy vegetables, fruiting vegetables, rooty vegetables and flour) products were collected from both local and non-local (commercial) sources. The local food samples were taken from 20 sampling points selected by taking into account the location of the possible PCDD/F sources, dominant wind directions and representing the major part of the Turkish daily diet The PCDD/F concentrations in local eggs and milk samples were ranged from <1.16 to 10.94 pg TEQ g(-1) fat and from <0.43 to 3.29 pg TEQ g(-1) fat, respectively. On the other hand, the PCDD/F concentrations were measured between 0.28-1.81 pg EQ g(-1) fat in local meat samples and 0.15-2.92 pg TEQ g(-1) fat in local chicken samples. The PCDD/F concentrations in the plant products were relatively low and most of the congeners were measured below the detection limits except for the leafy vegetables. In addition, several commercial samples were analyzed in order to evaluate the differences of PCDD/F levels in samples collected from both the local and non-local sources. The results showed that the local animal products have higher PCDD/F concentrations than the non-local ones. Moreover, the commercial plant products showed undetectable concentrations for most of the congeners. Finally, the PCDD/F levels in some animal products were found to be higher than the national limit values.

  14. Towards a phylogenetic generic classification of Thelypteridaceae: Additional sampling suggests alterations of neotropical taxa and further study of paleotropical genera.

    PubMed

    Almeida, Thaís Elias; Hennequin, Sabine; Schneider, Harald; Smith, Alan R; Batista, João Aguiar Nogueira; Ramalho, Aline Joseph; Proite, Karina; Salino, Alexandre

    2016-01-01

    Thelypteridaceae is one of the largest fern families, having about 950 species and a cosmopolitan distribution but with most species occurring in tropical and subtropical regions. Its generic classification remains controversial, with different authors recognizing from one up to 32 genera. Phylogenetic relationships within the family have not been exhaustively studied, but previous studies have confirmed the monophyly of the lineage. Thus far, sampling has been inadequate for establishing a robust hypothesis of infrafamilial relationships within the family. In order to understand phylogenetic relationships within Thelypteridaceae and thus to improve generic reclassification, we expand the molecular sampling, including new samples of Old World taxa and, especially, many additional neotropical representatives. We also explore the monophyly of exclusively or mostly neotropical genera Amauropelta, Goniopteris, Meniscium, and Steiropteris. Our sampling includes 68 taxa and 134 newly generated sequences from two plastid genomic regions (rps4-trnS and trnL-trnF), plus 73 rps4 and 72 trnL-trnF sequences from GenBank. These data resulted in a concatenated matrix of 1980 molecular characters for 149 taxa. The combined data set was analyzed using maximum parsimony and bayesian inference of phylogeny. Our results are consistent with the general topological structure found in previous studies, including two main lineages within the family: phegopteroid and thelypteroid. The thelypteroid lineage comprises two clades; one of these included the segregates Metathelypteris, Coryphopteris, and Amauropelta (including part of Parathelypteris), whereas the other comprises all segregates of Cyclosorus s.l., such as Goniopteris, Meniscium, and Steiropteris (including Thelypteris polypodioides, previously incertae sedis). The three mainly neotropical segregates were found to be monophyletic but nested in a broadly defined Cyclosorus. The fourth mainly neotropical segregate, Amauropelta

  15. Towards a phylogenetic generic classification of Thelypteridaceae: Additional sampling suggests alterations of neotropical taxa and further study of paleotropical genera.

    PubMed

    Almeida, Thaís Elias; Hennequin, Sabine; Schneider, Harald; Smith, Alan R; Batista, João Aguiar Nogueira; Ramalho, Aline Joseph; Proite, Karina; Salino, Alexandre

    2016-01-01

    Thelypteridaceae is one of the largest fern families, having about 950 species and a cosmopolitan distribution but with most species occurring in tropical and subtropical regions. Its generic classification remains controversial, with different authors recognizing from one up to 32 genera. Phylogenetic relationships within the family have not been exhaustively studied, but previous studies have confirmed the monophyly of the lineage. Thus far, sampling has been inadequate for establishing a robust hypothesis of infrafamilial relationships within the family. In order to understand phylogenetic relationships within Thelypteridaceae and thus to improve generic reclassification, we expand the molecular sampling, including new samples of Old World taxa and, especially, many additional neotropical representatives. We also explore the monophyly of exclusively or mostly neotropical genera Amauropelta, Goniopteris, Meniscium, and Steiropteris. Our sampling includes 68 taxa and 134 newly generated sequences from two plastid genomic regions (rps4-trnS and trnL-trnF), plus 73 rps4 and 72 trnL-trnF sequences from GenBank. These data resulted in a concatenated matrix of 1980 molecular characters for 149 taxa. The combined data set was analyzed using maximum parsimony and bayesian inference of phylogeny. Our results are consistent with the general topological structure found in previous studies, including two main lineages within the family: phegopteroid and thelypteroid. The thelypteroid lineage comprises two clades; one of these included the segregates Metathelypteris, Coryphopteris, and Amauropelta (including part of Parathelypteris), whereas the other comprises all segregates of Cyclosorus s.l., such as Goniopteris, Meniscium, and Steiropteris (including Thelypteris polypodioides, previously incertae sedis). The three mainly neotropical segregates were found to be monophyletic but nested in a broadly defined Cyclosorus. The fourth mainly neotropical segregate, Amauropelta

  16. Global requirements for DNA sample collections: results of a survey of 204 ethics committees in 40 countries.

    PubMed

    Ricci, D S; Broderick, E D; Tchelet, A; Hong, F; Mayevsky, S; Mohr, D M; Schaffer, M E; Warner, A W; Hakkulinen, P; Snapir, A

    2011-04-01

    The Industry Pharmacogenomics Working Group has an interest in attaining a better understanding of global requirements for sample collections intended for pharmacogenetics research. To have adequately powered pharmacogenetics studies representative of the clinical trial population, it is important to collect DNA samples from a majority of consenting study participants under many institutional review board/ethics committee (IRB/EC) jurisdictions. A survey was distributed to gather information from local and central IRBs/ECs. The survey included questions related to the approval of pharmacogenetics studies, collection and banking of samples, and return of data to subjects. A total of 204 responses were received from global IRBs/ECs with pharmacogenetic experience. The data show that requirements for approval of pharmacogenetic research differ between IRBs/ECs within and between countries but not between regions of the United States. A better understanding of differing requirements should facilitate global sample collection of DNA for pharmacogenetics research and may provide the basis for harmonized regulations for collection of genetic samples in the future. PMID:21346753

  17. Euromet-A Programme for the Collection of New Extraterrestrial Samples: Progress, Plans, or Pipe-Dreams?

    NASA Astrophysics Data System (ADS)

    Pillinger, C. T.

    1992-07-01

    EUROMET came into being in the wake of the Meteoritical Society Conference held in Vienna in 1989. It is now funded by the European Community Science Programme (Contract No. SC1* - CT91- 0618 (SSMA)) until November 1993, to collect and curate new meteorites and cosmic dust and distribute samples of the material on a worldwide basis. Although the progress towards fully operational status may seem slow, a great many people have contributed substantial amounts of time and effort to establishing a many-faceted project. EUROMET has held three very successful field expeditions to the Frontier Mountains (courtesy of the Italian Progetto Antartide), Dumont d'Urville together with Expeditions Polaires Francaises; Terres Australes et Antarctiques Francaises, and to the Nullarbor Plain (in conjunction with Dr. Alex Bevan, Western Australian Museum WAMET). The curatorial responsibilities extend to over 900 meteorite specimens and in excess of 10,000 cosmic dust grains. More information about these collections is provided elsewhere (several abstracts, this volume) with future updates to be published in the Meteoritical Bulletin. An electronic newsletter will be coming on line for rapid dissemination of information concerning sample characterisation and availability. Information regarding submission of sample requests can be found published in Meteoritics 27, 110 (1992). The EUROMET Council is actively pursuing a number of possibilities to ensure a long-term commitment to meteorite and micrometeorite recovery. Although many of the plans are still tentative they are moving towards fruition. Future Antarctic activities will hopefully include a 1992/3 mission to Frontier Mountains and other locations in Victoria Land and a more sophisticated cosmic dust factory (1994/5) with sponsors as before. Additionally we are exploring the possibility of a joint EUROMET/Indian expedition to Wohlthat Massif, which will be followed up via the German Georg Forster base in conjunction with Ganovex

  18. Growth and parameters of microflora in intestinal and faecal samples of piglets due to application of a phytogenic feed additive.

    PubMed

    Muhl, A; Liebert, F

    2007-10-01

    A commercial phytogenic feed additive (PFA), containing the fructopolysaccharide inulin, an essential oil mix (carvacrol, thymol), chestnut meal (tannins) and cellulose powder as carrier substance, was examined for effects on growth and faecal and intestinal microflora of piglets. Two experiments (35 days) were conducted, each with 40 male castrated weaned piglets. In experiment 1, graded levels of the PFA were supplied (A1: control; B1: 0.05% PFA; C1: 0.1% PFA; D1: 0.15% PFA) in diets based on wheat, barley, soybean meal and fish meal with lysine as the limiting amino acid. In experiment 2, a similar diet with 0.1% of the PFA (A2: control; B2: 0.1% PFA; C2: +0.35% lysine; D2: 0.1% PFA + 0.35% lysine) and lysine supplementation was utilized. During experiment 1, no significant effect of the PFA on growth, feed intake and feed conversion rate was observed (p > 0.05). Lysine supplementation in experiment 2 improved growth performance significantly, but no significant effect of the PFA was detected. Microbial counts in faeces (aerobes, Gram negatives, anaerobes and lactobacilli) during the first and fifth week did not indicate any significant PFA effect (p > 0.05). In addition, microflora in intestinal samples was not significantly modified by supplementing the PFA (p > 0.05). Lysine supplementation indicated lysine as limiting amino acid in the basal diet, but did not influence the microbial counts in faeces and small intestine respectively.

  19. 26 CFR 31.6001-5 - Additional records in connection with collection of income tax at source on wages.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... collection of income tax at source on wages. 31.6001-5 Section 31.6001-5 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) EMPLOYMENT TAXES AND COLLECTION OF INCOME TAX AT SOURCE EMPLOYMENT TAXES AND COLLECTION OF INCOME TAX AT SOURCE Administrative Provisions of Special Application...

  20. 26 CFR 31.6001-5 - Additional records in connection with collection of income tax at source on wages.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... collection of income tax at source on wages. 31.6001-5 Section 31.6001-5 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) EMPLOYMENT TAXES AND COLLECTION OF INCOME TAX AT SOURCE EMPLOYMENT TAXES AND COLLECTION OF INCOME TAX AT SOURCE Administrative Provisions of Special Application...

  1. 9 CFR 147.12 - Procedures for collection, isolation, and identification of Salmonella from environmental samples...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...: For Federal Register citations affecting § 147.12, see the List of CFR Sections Affected, which... each sample with a sterile tongue depressor or similar uncontaminated instrument. The samples shall... with a sterile tongue depressor or similar uncontaminated instrument. The samples should vary in...

  2. 9 CFR 147.12 - Procedures for collection, isolation, and identification of Salmonella from environmental samples...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...: For Federal Register citations affecting § 147.12, see the List of CFR Sections Affected, which... each sample with a sterile tongue depressor or similar uncontaminated instrument. The samples shall... with a sterile tongue depressor or similar uncontaminated instrument. The samples should vary in...

  3. MACRO- MICRO-PURGE SOIL GAS SAMPLING METHODS FOR THE COLLECTION OF CONTAMINANT VAPORS

    EPA Science Inventory

    Purging influence on soil gas concentrations for volatile organic compounds (VOCs), as affected by sampling tube inner diameter and sampling depth (i.e., dead-space purge volume), was evaluated at different field sites. A macro-purge sampling system consisted of a standard hollo...

  4. Analytical results for 544 water samples collected in the Attean Quartz Monzonite in the vicinity of Jackman, Maine

    USGS Publications Warehouse

    Ficklin, W.H.; Nowlan, G.A.; Preston, D.J.

    1983-01-01

    Water samples were collected in the vicinity of Jackman, Maine as a part of the study of the relationship of dissolved constituents in water to the sediments subjacent to the water. Each sample was analyzed for specific conductance, alkalinity, acidity, pH, fluoride, chloride, sulfate, phosphate, nitrate, sodium, potassium, calcium, magnesium, and silica. Trace elements determined were copper, zinc, molybdenum, lead, iron, manganese, arsenic, cobalt, nickel, and strontium. The longitude and latitude of each sample location and a sample site map are included in the report as well as a table of the analytical results.

  5. A study on the levels of a polybrominated biphenyl in Chinese human milk samples collected in 2007 and 2011.

    PubMed

    Liu, Xiao; Wen, Sheng; Li, Jingguang; Zhang, Lei; Zhao, Yunfeng; Wu, Yongning

    2016-09-01

    The levels of a 2,2',4,4',5,5'-hexabromobiphenyl (BB-153) were measured in human milk samples collected in 2007 and 2011 from residents in China by high-resolution gas chromatography-high-resolution mass chromatography (HRGC-HRMS) with isotope dilution. The median concentrations of BB-153 from the samples collected in 2007 and 2011 were 8.3 and 7.2 pg/g lipid weight, respectively. The levels of BB-153 in the human milk collected from rural areas were not significantly different to those collected from the urban areas in China. Meanwhile, significant positive correlations were found between the levels of BB-153 in human milk and the consumption of animal-origin foods. In the present study, the mean levels of BB-153 in human milk from Chinese mothers were found to be lower than those from European and American mothers.

  6. A study on the levels of a polybrominated biphenyl in Chinese human milk samples collected in 2007 and 2011.

    PubMed

    Liu, Xiao; Wen, Sheng; Li, Jingguang; Zhang, Lei; Zhao, Yunfeng; Wu, Yongning

    2016-09-01

    The levels of a 2,2',4,4',5,5'-hexabromobiphenyl (BB-153) were measured in human milk samples collected in 2007 and 2011 from residents in China by high-resolution gas chromatography-high-resolution mass chromatography (HRGC-HRMS) with isotope dilution. The median concentrations of BB-153 from the samples collected in 2007 and 2011 were 8.3 and 7.2 pg/g lipid weight, respectively. The levels of BB-153 in the human milk collected from rural areas were not significantly different to those collected from the urban areas in China. Meanwhile, significant positive correlations were found between the levels of BB-153 in human milk and the consumption of animal-origin foods. In the present study, the mean levels of BB-153 in human milk from Chinese mothers were found to be lower than those from European and American mothers. PMID:27521000

  7. Sample Collection from Small Airless Bodies: Examination of Temperature Constraints for the TGIP Sample Collector for the Hera Near-Earth Asteroid Sample Return Mission

    NASA Technical Reports Server (NTRS)

    Franzen, M. A.; Roe, L. A.; Buffington, J. A.; Sears, D. W. G.

    2005-01-01

    There have been a number of missions that have explored the solar system with cameras and other instruments but profound questions remain that can only be addressed through the analysis of returned samples. However, due to lack of appropriate technology, high cost, and high risk, sample return has only recently become a feasible part of robotic solar system exploration. One specific objective of the President s new vision is that robotic exploration of the solar system should enhance human exploration as it discovers and understands the the solar system, and searches for life and resources [1]. Missions to small bodies, asteroids and comets, will partially fill the huge technological void between missions to the Moon and missions to Mars. However, such missions must be low cost and inherently simple, so they can be applied routinely to many missions. Sample return from asteroids, comets, Mars, and Jupiter s moons will be an important and natural part of the human exploration of space effort. Here we describe the collector designed for the Hera Near-Earth Asteroid Sample Return Mission. We have built a small prototype for preliminary evaluation, but expect the final collector to gather approx.100 g of sample of dust grains to centimeter sized clasts on each application to the surface of the asteroid.

  8. Molecular Epidemiology of HIV-1 in Panama: Origin of Non-B Subtypes in Samples Collected from 2007 to 2013

    PubMed Central

    Mendoza, Yaxelis; Bello, Gonzalo; Castillo Mewa, Juan; Martínez, Alexander A.; González, Claudia; García-Morales, Claudia; Avila-Ríos, Santiago; Reyes-Terán, Gustavo; Pascale, Juan M.

    2014-01-01

    Phylogenetic studies have suggested that the HIV-1 epidemic in the Americas is mainly dominated by HIV subtype B. However, countries of South America and the Caribbean have recently reported changes in their circulating HIV-1 genetic profiles. The aim of this study was to characterize the molecular profile of the HIV-1 epidemic in Panama by the analysis of 655 polymerase gene (pol) sequences that were obtained from HIV-infected Panamanians diagnosed between 1987 and 2013. Blood samples were collected from recently infected, antiretroviral drug-naïve and treatment-experienced subjects since mid-2007 to 2013. Viral RNA from plasma was extracted and sequences of HIV protease and reverse transcriptase genes were obtained. Bootscanning and phylogenetic methods were used for HIV subtyping and to trace the putative origin of non-B subtype strains. Our results showed that HIV-1 infections in Panama are dominated by subtype B (98.9%). The remaining 1.1% is represented by a diverse collection of recombinant variants including: three URFs_BC, one CRF20_BG, and one CRF28/29_BF, in addition to one subtype F1 and one subtype C, none of which were previously reported in Panama. The non-B subtype variants detected in Panama were probably introduced from Brazil (subtype F1 and CRF28/29_BF), Cuba (CRF20_BG), Dominican Republic (URFs_BC) and India (subtype C). Panama is the geographical vertex that connects the North with South America and the Caribbean through trade and cultural relations, which may explain the observed introductions of non-B subtype HIV-1 variants from both the Caribbean and South America into this Central American country. PMID:24454808

  9. Molecular epidemiology of HIV-1 in Panama: origin of non-B subtypes in samples collected from 2007 to 2013.

    PubMed

    Mendoza, Yaxelis; Bello, Gonzalo; Castillo Mewa, Juan; Martínez, Alexander A; González, Claudia; García-Morales, Claudia; Avila-Ríos, Santiago; Reyes-Terán, Gustavo; Pascale, Juan M

    2014-01-01

    Phylogenetic studies have suggested that the HIV-1 epidemic in the Americas is mainly dominated by HIV subtype B. However, countries of South America and the Caribbean have recently reported changes in their circulating HIV-1 genetic profiles. The aim of this study was to characterize the molecular profile of the HIV-1 epidemic in Panama by the analysis of 655 polymerase gene (pol) sequences that were obtained from HIV-infected Panamanians diagnosed between 1987 and 2013. Blood samples were collected from recently infected, antiretroviral drug-naïve and treatment-experienced subjects since mid-2007 to 2013. Viral RNA from plasma was extracted and sequences of HIV protease and reverse transcriptase genes were obtained. Bootscanning and phylogenetic methods were used for HIV subtyping and to trace the putative origin of non-B subtype strains. Our results showed that HIV-1 infections in Panama are dominated by subtype B (98.9%). The remaining 1.1% is represented by a diverse collection of recombinant variants including: three URFs_BC, one CRF20_BG, and one CRF28/29_BF, in addition to one subtype F1 and one subtype C, none of which were previously reported in Panama. The non-B subtype variants detected in Panama were probably introduced from Brazil (subtype F1 and CRF28/29_BF), Cuba (CRF20_BG), Dominican Republic (URFs_BC) and India (subtype C). Panama is the geographical vertex that connects the North with South America and the Caribbean through trade and cultural relations, which may explain the observed introductions of non-B subtype HIV-1 variants from both the Caribbean and South America into this Central American country.

  10. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    NASA Astrophysics Data System (ADS)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  11. The effect of nocturnal sampling on semen quality and the efficiency of collection in bovine species.

    PubMed

    Yates, Jennifer H; Chandler, John E; Canal, Anita L; Braden Paul, J

    2003-12-01

    This study evaluated night and day semen collection regimes in Holstein and Brahman bulls (four bulls of each breed) that were collected weekly, each during a morning and a night collection. Ejaculates (n=64) were obtained via artificial vagina over 4 weeks. The first collection of each week alternated between night and day. Two collection teams were employed. Bull behavior parameters included reaction time to first mount, time to ejaculation, a refractory period test, and a thrust intensity test. The numbers of interruptions were counted as a managerial parameter. Pre-freeze semen parameters included total volume, initial motility and concentration. Post-freeze semen parameters measured were: 0- and 3-h post-thaw motility; percent intact acrosomes; and percent sperm abnormalities. Data were analyzed by least squares methods. The bull within breed effect differed (P<0.05) for behavior parameters. The bull within breed effect for total motile sperm harvested was not significant. The bull within breed response was mixed for post-freeze semen viability parameters. Bull within breed was not significant for sperm abnormalities. The night versus day treatment was significant for the managerial parameter (P=0.002). Although a different collection schedule for Bos indicus cattle was not warranted, the efficiency of the collection process was affected by extraneous environmental conditions. PMID:14580649

  12. The focus on sample quality: Influence of colon tissue collection on reliability of qPCR data

    PubMed Central

    Korenkova, Vlasta; Slyskova, Jana; Novosadova, Vendula; Pizzamiglio, Sara; Langerova, Lucie; Bjorkman, Jens; Vycital, Ondrej; Liska, Vaclav; Levy, Miroslav; Veskrna, Karel; Vodicka, Pavel; Vodickova, Ludmila; Kubista, Mikael; Verderio, Paolo

    2016-01-01

    Successful molecular analyses of human solid tissues require intact biological material with well-preserved nucleic acids, proteins, and other cell structures. Pre-analytical handling, comprising of the collection of material at the operating theatre, is among the first critical steps that influence sample quality. The aim of this study was to compare the experimental outcomes obtained from samples collected and stored by the conventional means of snap freezing and by PAXgene Tissue System (Qiagen). These approaches were evaluated by measuring rRNA and mRNA integrity of the samples (RNA Quality Indicator and Differential Amplification Method) and by gene expression profiling. The collection procedures of the biological material were implemented in two hospitals during colon cancer surgery in order to identify the impact of the collection method on the experimental outcome. Our study shows that the pre-analytical sample handling has a significant effect on the quality of RNA and on the variability of qPCR data. PAXgene collection mode proved to be more easily implemented in the operating room and moreover the quality of RNA obtained from human colon tissues by this method is superior to the one obtained by snap freezing. PMID:27383461

  13. The 'Prof. Dr. Rómulo Lambre' Collection: an Argentinian sample of modern skeletons.

    PubMed

    Salceda, S A; Desántolo, B; Mancuso, R García; Plischuk, M; Inda, A M

    2012-08-01

    This paper describes the 'Prof. Dr. Rómulo Lambre' skeletal collection. The Lambre Collection is housed in the School of Medical Sciences of the National University of La Plata and it consists of skeletal remains ceded by the Municipal Cemetery of La Plata. The collection has more than four hundred skeletons, with information on age, sex, nationality, date and cause of death. It was created for teaching and research purposes in compliance with current legislation, and its management meets guidelines specified in the Declaration of the Argentinian Association for Biological Anthropology on Research Ethics on Human Remains (2007).

  14. Challenges in collecting clinical samples for research from pregnant women of South Asian origin: evidence from a UK study

    PubMed Central

    Neelotpol, Sharmind; Hay, Alastair W M; Jolly, A Jim; Woolridge, Mike W

    2016-01-01

    Objective To recruit South Asian pregnant women, living in the UK, into a clinicoepidemiological study for the collection of lifestyle survey data and antenatal blood and to retain the women for the later collection of cord blood and meconium samples from their babies for biochemical analysis. Design A longitudinal study recruiting pregnant women of South Asian and Caucasian origin living in the UK. Setting Recruitment of the participants, collection of clinical samples and survey data took place at the 2 sites within a single UK Northern Hospital Trust. Participants Pregnant women of South Asian origin (study group, n=98) and of Caucasian origin (comparison group, n=38) living in Leeds, UK. Results Among the participants approached, 81% agreed to take part in the study while a ‘direct approach’ method was followed. The retention rate of the participants was a remarkable 93.4%. The main challenges in recruiting the ethnic minority participants were their cultural and religious conservativeness, language barrier, lack of interest and feeling of extra ‘stress’ in taking part in research. The chief investigator developed an innovative participant retention method, associated with the women's cultural and religious practices. The method proved useful in retaining the participants for about 5 months and in enabling successful collection of clinical samples from the same mother–baby pairs. The collection of clinical samples and lifestyle data exceeded the calculated sample size required to give the study sufficient power. The numbers of samples obtained were: maternal blood (n=171), cord blood (n=38), meconium (n=176), lifestyle questionnaire data (n=136) and postnatal records (n=136). Conclusions Recruitment and retention of participants, according to the calculated sample size, ensured sufficient power and success for a clinicoepidemiological study. Results suggest that development of trust and confidence between the participant and the researcher is the

  15. Development and characterization of an electrostatic particle sampling system for the selective collection of trace explosives.

    PubMed

    Beer, Sebastian; Müller, Gerhard; Wöllenstein, Jürgen

    2012-01-30

    Detection of trace explosives residues at people and cargo control points has become a key security challenge. A severe obstacle is that all commercial and military high explosives have low to extremely low vapor pressures which make them very hard to detect. With detectable vapors not being present, explosives detection needs to proceed through a series of sequential steps including particle collection, thermal vapor conversion and vapor detection. The present paper describes the design and test of an electrostatic particle precipitator which allows particle residue to be collected from the environment, the collected particle residue to be separated into high- and low-electron affinity fractions and the high-electron-affinity one to be concentrated onto a small-area collector surface for later vaporization. The selectivity of this particle collection and separation process is demonstrated and a full-chain demonstration of a DNT detection experiment is presented (DNT: di-nitro-toluene).

  16. 76 FR 24862 - Proposed Information Collection; Comment Request; Protocol for Access to Tissue Specimen Samples...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-03

    ... information collection instrument and instructions should be directed to Patricia Lawson, 301-713-2289 or at Patricia.Lawson@noaa.gov . SUPPLEMENTARY INFORMATION: I. Abstract In 1989, the National Marine...

  17. Microbiological quality and sample collection policy for dairy products in Ramallah and Al-Bireh district, Palestine.

    PubMed

    Al-Khatib, I A; Al-Mitwalli, S M

    2009-01-01

    We aimed to identify bacterial pathogens/contaminants in dairy product samples collected by environmental health inspectors of the Palestinian Ministry of Health from 2001-04. A total of 722 samples of dairy products were randomly collected from different sources in Ramallah and Al-Bireh district. The percentages of unacceptable samples for the combined years were: 23.0% for total aerobic count, 21.0% for total coliforms, 15.2% for faecal coliforms, 1.0% for Staphylococcus aureus, 10.3% for moulds, 2.3% for yeasts and 14.3% for Escherichia coli. All the examined samples tested negative for Salmonella spp. Total aerobic counts rose continuously between 2001 and 2004.

  18. Detection of Vibrio cholerae and Acanthamoeba species from same natural water samples collected from different cholera endemic areas in Sudan

    PubMed Central

    2011-01-01

    Background Vibrio cholerae O1 and V. cholerae O139 infect humans, causing the diarrheal and waterborne disease cholera, which is a worldwide health problem. V. cholerae and the free-living amoebae Acanthamoeba species are present in aquatic environments, including drinking water and it has shown that Acanthamoebae support bacterial growth and survival. Recently it has shown that Acanthamoeba species enhanced growth and survival of V. cholerae O1 and O139. Water samples from different cholera endemic areas in Sudan were collected with the aim to detect both V. cholerae and Acanthamoeba species from same natural water samples by polymerase chain reaction (PCR). Findings For the first time both V. cholerae and Acanthamoeba species were detected in same natural water samples collected from different cholera endemic areas in Sudan. 89% of detected V. cholerae was found with Acanthamoeba in same water samples. Conclusions The current findings disclose Acanthamoedae as a biological factor enhancing survival of V. cholerae in nature. PMID:21470437

  19. Evidence for microorganisms in stratosphere air samples collected at a height of 41km

    NASA Astrophysics Data System (ADS)

    Wainwright, Milton; Wickramasinghe, Nalin C.; Narlikar, J. V.; Rajaratnam, P.

    2003-02-01

    Samples of air removed from the stratosphere, at an altitude of 41km, were previously found to contain viable, but non-cultureable bacteria (cocci and rods). Here, we describe experiments aimed at growing these organisms, together with any others, present in the samples. Two bacteria (Bacillus simplex and Staphylococcus pasteuri) and a single fungus, Engyodontium albus (limber)de Hoog were isolated from the samples. Contamination can never be ruled out when space-derived samples are studied on earth, however, we are confident that the organisms isolated here originated from the stratosphere.

  20. Analyses of Gas, Steam and Water Samples Collected in and Around Lassen Volcanic National Park, California, 1975-2002

    USGS Publications Warehouse

    Janik, Cathy J.; Bergfeld, D.

    2010-01-01

    This report contains physical and chemical data from gas, steam, and water samples collected between July 1975 and September 2002 from locations in and around Lassen Volcanic National Park, California. Data are compiled as tables in Excel spreadsheets and are organized by locale. Most data are keyed to 1 of 107 site codes that are shown on local- and regional-scale maps. Brief descriptions of terminology, sampling, and analytical methods are provided.

  1. Investigation into Alternative Sample Preparation Techniques for the Determination of Heavy Metals in Stationary Source Emission Samples Collected on Quartz Filters

    PubMed Central

    Goddard, Sharon L.; Brown, Richard J. C.

    2014-01-01

    Monitoring stationary source emissions for heavy metals generally requires the use of quartz filters to collect samples because of the high temperature and high moisture sampling environment. The documentary standard method sample preparation technique in Europe, EN 14385, uses digestion in hydrofluoric acid and nitric acid (HF/HNO3) followed by complexing with boric acid (H3BO3) prior to analysis. However, the use of this method presents a number of problems, including significant instrumental drift during analysis caused by the matrix components, often leading to instrument breakdown and downtime for repairs, as well as posing significant health and safety risks. The aim of this work was to develop an alternative sample preparation technique for emissions samples on quartz filters. The alternative techniques considered were: (i) acid digestion in a fluoroboric acid (HBF4) and HNO3 mixture and (ii) acid extraction in an aqua regia (AR) mixture (HCl and HNO3). Assessment of the effectiveness of these options included determination of interferences and signal drift, as well as validating the different methods by measurement of matrix certified reference materials (CRMs), and comparing the results obtained from real test samples and sample blanks to determine limits of detection. The results showed that the HBF4/HNO3 mixture provides the most viable alternative to the documentary standard preparation technique. PMID:25407906

  2. Preconcentration of diluted mixed-species samples following separation and collection in a micro-nanofluidic device.

    PubMed

    Chen, Yi-Ying; Chiu, Ping-Hsien; Weng, Chen-Hsun; Yang, Ruey-Jen

    2016-01-01

    A microfluidic device consisting of a nanoscale Nafion membrane and a polydimethylsiloxane microchannel is proposed for the preconcentration of diluted multi-mixed species samples then following separation and collection. When an electric field is applied across the microchip, an accumulation of the mixed-species sample occurs at the junction between the microchannel and the membrane by means of ion concentration polarization effect. A separation of the sample then takes place due to the difference in the electrophoretic mobilities of the sample components. Finally, the component of interest is guided to a collection reservoir by manipulating the external potential configuration and is trapped in place by means of a magnetically actuated valve. The preconcentration performance of the proposed device is evaluated in both straight and convergent microchannels using a fluorescein isothiocyanate labeled bovine serum albumin (FITC-BSA) sample. It is shown that a preconcentration factor of 40 times can be achieved using a straight microchannel. By contrast, the preconcentration factor increases to 50 times when using a convergent channel. The practical feasibility of the proposed device is demonstrated by performing the preconcentration, separation, and collection of a mixed FITC-BSA and Tetramethylrhodamine sample. PMID:26909125

  3. Homologue and isomer distribution of dioxins observed in water samples collected from Kahokugata Lagoon and inflowing rivers, Japan.

    PubMed

    Kakimoto, Hitoshi; Oka, Hideo; Miyata, Yoshiaki; Yonezawa, Yumiko; Niikawa, Akiko; Kyudo, Hirohisa; Tang, Ning; Toriba, Akira; Kizu, Ryoichi; Hayakawa, Kazuichi

    2006-06-01

    Water samples were collected at 17 sites in Kahokugata Water Basin, a closed water basin in central Japan. We determined the concentration of dioxins of the water samples. Linear relationships between toxic equivalent (TEQ) concentrations of dioxin and concentrations of suspended solid (SS) were obtained at sites in Kahokugata Lagoon and in the rivers flowing into the lagoon. Homologue composition of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) indicated that all the water samples were still strongly influenced by chlorinated herbicides, such as chloronitrofen (CNP) and pentachlorophenol (PCP) that had been widely used in rice fields. The main isomer distributions of the PCDD homologues were not significantly different among the sampling sites, while the main isomer distributions of the PCDF homologues were considerably different among the sampling sites. At a few sampling points in the downstream part of one of the rivers, high concentrations of 1,3,6,7,8-pentachloro dibenzofuran (1,3,6,7,8-PeCDF) and its related isomers (1,3,6,8-chlorine-substituted PCDFs) were traced to a dye manufacturing plant. These non-toxic isomers are usually only minor constituents in environmental water samples and are not indicators of any known dioxin sources. The dyeing discharge was found to make a contribution only in the water samples collected near the plant and the seasonal variation of the contribution might depend on the flow rate of the river.

  4. Detection of environmental DNA of Bigheaded Carps in samples collected from selected locations in the St. Croix River and in the Mississippi River

    USGS Publications Warehouse

    Amberg, Jon J.; McCalla, S. Grace; Miller, Loren; Sorensen, Peter; Gaikowski, Mark P.

    2013-01-01

    Assurance Project Plan with minor deviations designed to enhance the rigor of our data. Presence of DNA in PCR-positive samples was confirmed by Sanger sequencing (forward and reverse) and sequences were considered positive only if sequences (forward and reverse) of ≥150 base pairs had a match of ≥95% to those of published sequences for bighead carp or silver carp. The DNA of bighead carp and silver carp was not detected in environmental samples collected above and below St. Croix Falls Dam on the St. Croix River, above and below the Coon Rapids Dam and below Lock and Dam 1 on the Upper Mississippi River, and from two negative control lakes, Square Lake and Lake Riley. The DNA of silver carp was detected in environmental samples collected below Lock and Dam 19 at Keokuk, Iowa, a reach of the river with high silver carp abundance. The portion (68%) of environmental samples taken below Lock and Dam 19 that were determined to contain the DNA of silver carp was similar to that reported in the scientific literature for other abundant species. The DNA of bighead carp, however, was not detected in environmental samples collected below Lock and Dam 19, a reach of the river known to have bighead carp. Previous reported detections of the DNA of silver carp in samples collected in 2011 were not replicated in this study. Additional analyses are planned for the DNA extracted from the samples collected in 2012. Those analyses may provide additional information regarding the lack of amplification of bighead carp DNA and the lengths of the sequences of silver carp DNA present in samples taken below Lock and Dam 19. These additional analyses may help inform the use of eDNA monitoring in large, complex systems like the Mississippi River.

  5. 77 FR 51818 - Agency Information Collection Activities; Application and Approval To Manipulate, Examine, Sample...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-27

    ... Approval To Manipulate, Examine, Sample, or Transfer Goods AGENCY: U.S. Customs and Border Protection... Approval to Manipulate, Examine, Sample, or Transfer Goods. This is a proposed extension of an information... change to the burden hours. This document is published to obtain comments from the public and...

  6. 7 CFR 52.45 - Inspection fees when charges for sampling have not been collected.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946 PROCESSED FRUITS AND VEGETABLES, PROCESSED PRODUCTS THEREOF, AND CERTAIN OTHER PROCESSED FOOD PRODUCTS 1 Regulations Governing Inspection and... any lot of processed products from which a sample is drawn by a licensed sampler and the sampling...

  7. 7 CFR 52.44 - Inspection fees when charges for sampling have been collected.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946 PROCESSED FRUITS AND VEGETABLES, PROCESSED PRODUCTS THEREOF, AND CERTAIN OTHER PROCESSED FOOD PRODUCTS 1 Regulations Governing Inspection and Certification... processed products from which a sample in drawn by a licensed sampler and the applicable sampling fee...

  8. 7 CFR 52.45 - Inspection fees when charges for sampling have not been collected.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946 PROCESSED FRUITS AND VEGETABLES, PROCESSED PRODUCTS THEREOF, AND CERTAIN OTHER PROCESSED FOOD PRODUCTS 1 Regulations Governing Inspection and... any lot of processed products from which a sample is drawn by a licensed sampler and the sampling...

  9. 7 CFR 52.44 - Inspection fees when charges for sampling have been collected.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946 PROCESSED FRUITS AND VEGETABLES, PROCESSED PRODUCTS THEREOF, AND CERTAIN OTHER PROCESSED FOOD PRODUCTS 1 Regulations Governing Inspection and Certification... processed products from which a sample in drawn by a licensed sampler and the applicable sampling fee...

  10. Analysis of Biodiesel Blends Samples Collected in the United States in 2008 (Revised)

    SciTech Connect

    Alleman, T. L.; Fouts, L.; McCormick, R. L.

    2010-12-01

    NREL sampled and tested the quality of U.S. B20 (20% biodiesel, 80% petroleum diesel) in 2008; 32 samples from retail locations and fleets were tested against a proposed ASTM D7467 B6-B20 specification, now in effect.

  11. Maximizing collection and minimizing risk: does vacuum suction sampling increase the likelihood for misinterpretation of food web connections?

    PubMed

    Chapman, Eric G; Romero, Susan A; Harwood, James D

    2010-11-01

    Molecular tools that characterize the structure of complex food webs and identify trophic connectedness in the field have become widely adopted in recent years. However, characterizing the intensity of predator-prey interactions can be prone to error. Maximizing collection success of small, fast-moving predators with vacuum suction samplers has the potential to increase the likelihood of prey DNA detection either through surface-level contamination with damaged prey or direct consumption within the sampling device. In this study, we used PCR to test the hypothesis that vacuum suction sampling will not cause an erroneous increase in the detection of 'predation', thereby incorrectly assigning trophic linkages when evaluating food web structure. We utilized general (1) Aphidoidea and (2) Collembola primers to measure the predation rates of Glenognatha foxi (Araneae: Tetragnathidae) on these prey collected by hand versus those sampled with a vacuum suction device. With both primer pairs, there was no significant increase in predators screening positive for prey DNA when sampled by vacuum suction versus those predators collected, in parallel, by hand. These results clearly validate the application of vacuum suction sampling during molecular gut-content analysis of predator-prey feeding linkages in the field. Furthermore, we found no evidence that predation was occurring inside the suction sampler because specimens collected were never observed to be feeding nor did they screen positive at greater frequencies than hand-collected individuals. Therefore, it can be concluded that the use of vacuum suction sampling devices (in this case a Modified CDC Backpack Aspirator Model 1412) is suitable for molecular gut-content analysis.

  12. Predictors of victim disclosure in child sexual abuse: Additional evidence from a sample of incarcerated adult sex offenders.

    PubMed

    Leclerc, Benoit; Wortley, Richard

    2015-05-01

    The under-reporting of child sexual abuse by victims is a serious problem that may prolong the suffering of victims and leave perpetrators free to continue offending. Yet empirical evidence indicates that victim disclosure rates are low. In this study, we perform regression analysis with a sample of 369 adult child sexual offenders to examine potential predictors of victim disclosure. Specifically, we extend the range of previously examined potential predictors of victim disclosure and investigate interaction effects in order to better capture under which circumstances victim disclosure is more likely. The current study differs from previous studies in that it examines the impact of victim and offense variables on victim disclosure from the perspective of the offender. In line with previous studies, we found that disclosure increased with the age of the victim and if penetration had occurred. In addition, we found that disclosure increased when the victim came from a non-dysfunctional family and resisted the abuse. The presence of an interaction effect highlighted the impact of the situation on victim disclosure. This effect indicated that as victims get older, they are more likely to disclose the abuse when they are not living with the offender at the time of abuse, but less likely to do so when they are living with the offender at the time of abuse. These findings are discussed in relation to previous studies and the need to facilitate victim disclosure.

  13. A Future Moon Mission: Curatorial Statistics on Regolith Fragments Applicable to Sample Collection by Raking

    NASA Technical Reports Server (NTRS)

    Allton, J. H.; Bevill, T. J.

    2003-01-01

    The strategy of raking rock fragments from the lunar regolith as a means of acquiring representative samples has wide support due to science return, spacecraft simplicity (reliability) and economy [3, 4, 5]. While there exists widespread agreement that raking or sieving the bulk regolith is good strategy, there is lively discussion about the minimum sample size. Advocates of consor-tium studies desire fragments large enough to support petrologic and isotopic studies. Fragments from 5 to 10 mm are thought adequate [4, 5]. Yet, Jolliff et al. [6] demonstrated use of 2-4 mm fragments as repre-sentative of larger rocks. Here we make use of cura-torial records and sample catalogs to give a different perspective on minimum sample size for a robotic sample collector.

  14. Illuminating the NARS data entry black box: what happens between sample collection and data availability for use in assessments?

    EPA Science Inventory

    The steps between field collection of data and samples and availability of the resulting data from National Aquatic Resource Surveys (NARS) can appear to be a black box. This presentation is intended to shed some light on that process. The pathway for data depends on their source...

  15. EVALUATING COMMERCIALLY AVAILABLE DERMAL WIPES, COTTON SUITES, AND ALTERNATIVE URINARY COLLECTION MATERIALS FOR PESTICIDE SAMPLING FROM INFANTS

    EPA Science Inventory

    As the Human Exposure Program focuses on the exposure of children to pesticides, there are concerns about the effect, or perceived effect, of components of the sampling procedure on the health and well-being of the infant and the ability to collect pesticide residues.

    One...

  16. RECOMMENDED OPERATING PROCEDURE NO. 56: COLLECTION OF GASEOUS GRAB SAMPLES FROM COMBUSTION SOURCES FOR NITROUS OXIDE MEASUREMENT

    EPA Science Inventory

    The document is a recommended operating procedure, prepare or use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). The procedure applies to the collection of gaseous grab samples from fossil fuel combustion sources for subsequent a...

  17. Detection of Group B Streptococcus Directly from Collected ESwab Samples by Use of the BD Max GBS Assay

    PubMed Central

    Rocchetti, Talita T.; Gostnell, Alicia; Kubasek, Carly; Widen, Raymond

    2016-01-01

    Group B Streptococcus detection directly from Copan ESwab collected samples, using the BD Max GBS assay, was evaluated on receipt in the laboratory and after 24 h at room temperature. Results were compared to those using Lim broth enrichment PCR and culture. No significant difference was observed between 24 h ESwab and Lim broth PCRs. PMID:27053670

  18. Swine gene banking: A quality control perspective on collection, and analysis of samples for a national repository

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The National Animal Germplasm Program (NAGP) is developing a national repository for germplasm (semen, oocytes, embryos, blood, DNA, tissue) for all agricultural species in the United States. Currently, the swine collection consists of 127,479 samples from 886 boars representing 20 major, minor and...

  19. Impact of 2'-hydroxyl sampling on the conformational properties of RNA: update of the CHARMM all-atom additive force field for RNA.

    PubMed

    Denning, Elizabeth J; Priyakumar, U Deva; Nilsson, Lennart; Mackerell, Alexander D

    2011-07-15

    Here, we present an update of the CHARMM27 all-atom additive force field for nucleic acids that improves the treatment of RNA molecules. The original CHARMM27 force field parameters exhibit enhanced Watson-Crick base pair opening which is not consistent with experiment, whereas analysis of molecular dynamics (MD) simulations show the 2'-hydroxyl moiety to almost exclusively sample the O3' orientation. Quantum mechanical (QM) studies of RNA related model compounds indicate the energy minimum associated with the O3' orientation to be too favorable, consistent with the MD results. Optimization of the dihedral parameters dictating the energy of the 2'-hydroxyl proton targeting the QM data yielded several parameter sets, which sample both the base and O3' orientations of the 2'-hydroxyl to varying degrees. Selection of the final dihedral parameters was based on reproduction of hydration behavior as related to a survey of crystallographic data and better agreement with experimental NMR J-coupling values. Application of the model, designated CHARMM36, to a collection of canonical and noncanonical RNA molecules reveals overall improved agreement with a range of experimental observables as compared to CHARMM27. The results also indicate the sensitivity of the conformational heterogeneity of RNA to the orientation of the 2'-hydroxyl moiety and support a model whereby the 2'-hydroxyl can enhance the probability of conformational transitions in RNA.

  20. Analyses of water, core material, and elutriate samples collected near Yazoo City, Mississippi (Yazoo Headwater Project)

    USGS Publications Warehouse

    Leone, Harold L.; Dupuy, Alton J.

    1978-01-01

    Five core-material-sampling sites near Yazoo City, Miss., were chosen by the U.S. Army Corps of Engineers to represent areas of proposed dredging activity. Four receiving-water sites also were selected to represent the water that will contact the proposed dredged material. Chemical and physical analyses were performed upon core material and native-water samples from these sites as well as upon elutriate samples of specific sediment-receiving water systems. The results of these analyses are presented without interpretation. (Woodard-USGS)

  1. Analyses of native water, core material, and elutriate samples collected from the Atchafalaya River and Atchafalaya Bay

    USGS Publications Warehouse

    Demas, Charles R.

    1977-01-01

    During October and November 1976 the U.S. Geological Survey, in cooperation with the U.S. Army Corps of Engineers, collected native water and core material from 14 sites along the Atchafalya River in Louisiana (from the head of Whiskey Bay Pilot Channel to American Pass) and 5 sites in Atchafalya Bay for evaluation of possible environmental effects of a proposed channel-enlargement project. Core material from all river sites and one bay site was collected to a depth of 50 feet (15 meters). At the remaining bay sites, samples were collected to a depth of less than 6 inches (15 centimeters) using a pipe dredge. Core material and native water were analyzed (separately and as elutriate samples prepared from mixtures) for selected metals, nutrients, organic compounds, and physical characteristics. No interpretation of the data is given. (Woodard-USGS)

  2. Performance of Self-Collected Cervical Samples in Screening for Future Precancer Using Human Papillomavirus DNA Testing

    PubMed Central

    Hildesheim, Allan; González, Paula; Schiffman, Mark; Rodríguez, Ana Cecilia; Wacholder, Sholom; Jiménez, Silvia; Quint, Wim; Guillen, Diego; Kreimer, Aimée R.; Herrero, Rolando

    2015-01-01

    Background: Self-collected human papillomavirus (HPV) testing could reduce barriers to cervical cancer screening, with performance comparable to clinician-collected specimens. The ability of self-collected specimens to cross-sectionally and prospectively detect precursor lesions was investigated in an HPV vaccine randomized trial in Costa Rica. Methods: In the trial, 7466 women age 18 to 25 years received an HPV16/18 or control vaccine and were followed at least annually for four years. In this secondary analysis, we included all women who provided a self-collected cervicovaginal specimen six months after enrollment (5109 women = full analytical cohort). A subset (615 women = restricted cohort) also had clinician-collected specimens at the six-month postenrollment visit. High-grade squamous intraepithelial lesion or repeat low-grade squamous intraepithelial lesion prompted colposcopic referral throughout the study. HPV testing was performed with SPF10PCR/DEIA/LiPA25. Cross-sectional and prospective sensitivity, specificity, and predictive values were estimated. Results: In the full cohort, one-time HPV testing on self-collected samples detected prevalent CIN2+ with a sensitivity of 88.7% (95% confidence interval [CI] =77.0% to 95.7%) and a specificity of 68.9% (95% CI = 67.6% to 70.1%). For predicting incident CIN2+ in the subsequent four years, sensitivity was 73.9% (95% CI = 65.8% to 81.0%) and specificity 69.4% (95% CI = 68.1% to 70.7%). In the restricted cohort, for incident CIN2+, self-collected HPV was much more sensitive than cytology (80.0% vs 10.0%); relative sensitivity was 0.1 (95% CI = 0.03% to 0.5%). Furthermore, three times more women with normal baseline cytology developed incident CIN2+ than those with negative self-collected HPV. Self-collected and clinician-collected HPV testing had comparable performance. Agreement between self- and clinician-collected samples was 89.7% (kappa = 0.78, McNemar χ2 = 0.62) for carcinogenic HPV types. Conclusions

  3. The brominated flame retardants, PBDEs and HBCD, in Canadian human milk samples collected from 1992 to 2005; concentrations and trends.

    PubMed

    Ryan, John Jake; Rawn, Dorothea F K

    2014-09-01

    Human milk samples were collected from individuals residing in various regions across Canada mostly in the years 1992 to 2005. These included five large cities in southern Canada as well as samples from Nunavik in northern Quebec. Comparative samples were also collected from residents of Austin, Texas, USA in 2002 and 2004. More than 300 milk samples were analysed for the brominated flame retardants (BFRs), PBDEs and HBCD, by extraction, purification and quantification using either isotope dilution gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-MS. The Canadian total PBDE values in the years 2002-2005 show median levels of about 20μg/kg on a lipid basis; a value significantly higher than in the 1980s and 1990s. Milk samples from Inuit donors in the northern region of Nunavik were slightly lower in PBDE concentrations than those from populated regions in the south of Quebec. Milk samples from Ontario contained slightly lower amounts of PBDEs in two time periods than those from Texas. HBCD levels in most milk samples were usually less than 1ppb milk lipid and dominated by the α-isomer. This large data set of BFRs in Canadian human milk demonstrates an increase in the last few decades in human exposure to BFRs which now appears to have stabilized.

  4. Evaluation of a novel tagging and tissue preservation system for potential use in forensic sample collection.

    PubMed

    Grassberger, Martin; Stein, Christina; Hanslik, Stefan; Hochmeister, Manfred

    2005-07-16

    The authors describe a new, easy-to-use barcode-based tissue collection, preservation and body tracking system, which might prove instrumental in the containment of mass fatalities such as aircraft accidents, war related accidents, environmental disasters (e.g. earthquakes, hurricanes, and floods) terrorist bombings or mass murders.

  5. CTEPP DATA COLLECTION FORM 01: RECRUITMENT SURVEY FOR DAY CARE CENTER SAMPLE SUBJECTS

    EPA Science Inventory

    This data collection form is used to identify eligible preschool children who attend day care during the day and recruit them into the study.

    The Children's Total Exposure to Persistent Pesticides and Other Persistent Pollutant (CTEPP) study was one of the largest aggregate ex...

  6. CTEPP DATA COLLECTION FORM 01_RDD: RECRUITMENT SURVEY FOR HOME SAMPLE SUBJECTS

    EPA Science Inventory

    This data collection form is used to identify eligible preschool children who stay home during the day with their primary adult care giver and recruit them into the study.

    The Children's Total Exposure to Persistent Pesticides and Other Persistent Pollutant (CTEPP) study was o...

  7. Evaluation of a novel tagging and tissue preservation system for potential use in forensic sample collection.

    PubMed

    Grassberger, Martin; Stein, Christina; Hanslik, Stefan; Hochmeister, Manfred

    2005-07-16

    The authors describe a new, easy-to-use barcode-based tissue collection, preservation and body tracking system, which might prove instrumental in the containment of mass fatalities such as aircraft accidents, war related accidents, environmental disasters (e.g. earthquakes, hurricanes, and floods) terrorist bombings or mass murders. PMID:15939157

  8. Operational Procedures for Collecting Water-Quality Samples at Monitoring Sites on Maple Creek Near Nickerson and the Platte River at Louisville, Eastern Nebraska

    USGS Publications Warehouse

    Johnson, Steven M.; Swanson, Robert B.

    1994-01-01

    Prototype stream-monitoring sites were operated during part of 1992 in the Central Nebraska Basins (CNBR) and three other study areas of the National Water-Quality Assessment (NAWQ) Program of the U.S. Geological Survey. Results from the prototype project provide information needed to operate a net- work of intensive fixed station stream-monitoring sites. This report evaluates operating procedures for two NAWQA prototype sites at Maple Creek near Nickerson and the Platte River at Louisville, eastern Nebraska. Each site was sampled intensively in the spring and late summer 1992, with less intensive sampling in midsummer. In addition, multiple samples were collected during two high- flow periods at the Maple Creek site--one early and the other late in the growing season. Water-samples analyses included determination of pesticides, nutrients, major ions, suspended sediment, and measurements of physical properties. Equipment and protocols for the water-quality sampling procedures were evaluated. Operation of the prototype stream- monitoring sites included development and comparison of onsite and laboratory sample-processing proce- dures. Onsite processing was labor intensive but allowed for immediate preservation of all sampled constituents. Laboratory processing required less field labor and decreased the risk of contamination, but allowed for no immediate preservation of the samples.

  9. Extent of sample loss on the sampling device and the resulting experimental biases when collecting volatile fatty acids (VFAs) in air using sorbent tubes.

    PubMed

    Kim, Yong-Hyun; Kim, Ki-Hyun

    2013-08-20

    Not all volatile organic compounds (VOCs) are suitable for sampling from air onto sorbent tubes (ST) with subsequent analysis by thermal desorption (TD) with gas chromatography (GC). Some compounds (such as C2 hydrocarbons) are too volatile for quantitative retention by sorbents at ambient temperature, while others are too reactive - either for storage stability on the tubes (post-sampling) or for thermal desorption/GC analysis. Volatile fatty acids (VFAs) are one of the compound groups that present a challenge to sorbent tube sampling. In this study, we evaluated sample losses on the inner wall surface of the sorbent tube sampler. The sorptive losses of five VFA (acetic, propionic, n-butyric, i-valeric, and n-valeric acid) were tested using two types of tubes (stainless steel and quartz), each packed with three sorbent beds arranged in order of sorbent strength from the sampling end of the tube (Tenax TA, Carbopack B, and Carbopack X). It showed significantly higher losses of VFAs in both liquid phase and vapor phase when using stainless steel tube samplers. These losses were also seen if vapor-phase fatty acids were passed through empty stainless steel tubing and increased dramatically with increasing molecular weight, e.g., losses of 33.6% (acetic acid) to 97.5% (n-valeric acid). Similar losses of VFAs were also observed from headspace sampling of cheese products. Considering that stainless steel sampling tubes are still used extensively by many researchers, their replacement with quartz tubes is recommended to reduce systematic biases in collecting VFA samples or in their calibration. PMID:23869450

  10. Evidence of 'CHOl' in sediment core samples of pacific ocean collected among FGGE

    SciTech Connect

    Han-chang, P.; Kui-huan, Z.; Sui-tian, C.

    1982-07-10

    Three new microtektite sites have been identified in addition to the known world distributions. This is of significance for confirming and extending the known range of tektite distributions and for a thorough study of their origin.

  11. Do Milk Samples Stored for 12 Days after Collection Exhibit a Change in Composition Related to the Initial Bacterial Load?

    PubMed

    de Freitas, Larissa Nazareth; Cassoli, Laerte Dagher; da Silva, Janielen; de Figueiredo Pantoja, José Carlos; Machado, Paulo Fernando

    2016-05-01

    Total bacterial count (TBC) is a tool used to assess milk quality and is associated with not only the initial sample contamination but also the sample storage time and temperature. Several countries have reported milk samples with a high TBC, and the influence of TBC on milk preservation remains unclear. Thus, the aim of this study was to evaluate the impact of the initial bacterial contamination level on the macrocomponents and somatic cell count (SCC) of raw milk samples preserved with bronopol and maintained at two storage temperatures (7 and 25°C) for up to 12 days. Thus, we collected milk samples from 51 dairy farms, which were divided into two groups according to the initial bacterial load: low TBC (<100,000 CFU/ml) and high TBC (≥100,000 CFU/ml). We analyzed the sample composition for protein, fat, total solids, lactose, milk urea nitrogen, and the SCC. We did not observe an effect from TBC and storage time and temperature on the concentration of protein, fat, total solids, and lactose. SCC changes were not observed for samples maintained under refrigeration (7°C); however, samples maintained at room temperature (25°C) exhibited a decrease in the SCC beginning on day 6 of storage. For milk urea nitrogen, values increased when the samples were maintained at room temperature, beginning on the ninth storage day. Samples with the preservative bronopol added and maintained under refrigeration may be analyzed up to 12 days after collection, regardless of the milk microbial load.

  12. Vapor space characterization of waste tank 241-BY-107: Results from samples collected on 10/26/94

    SciTech Connect

    Clauss, T.W.; Ligotke, M.W.; Pool, K.H.

    1995-10-01

    This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-BY-107 (referred to as Tank BY-107). Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The organic analytes for TO-14 compounds were extended to include 15 analytes identified by the Toxicological Review Panel for Tank C-103 and reported in Toxicological Evaluation of Analytes from Tank 241-C-103 PAE-10189. While these analytes are only of toxicological concern for Tank C-103, program management included these analytes for future tank analyses as identified in the fiscal year work plan. This plan is attached to a letter dated 9/30/94 and addressed to Mr. T. J. Kelly of WHC. The plan also requires PNL to analyze for the permanent gases as shown in Table 3.5. The sample job was designated S4077, and samples were collected by WHC on October 26, 1994, using the vapor sampling system (VSS). Sampling devices, including six sorbent trains (for inorganic analyses), and six SUMMA{trademark} canisters (for organic analyses) were supplied to the WHC sampling staff on October 24. Samples were taken (by WHC) from the tank headspace on October 26 and were returned to PNL from the field on November 8. Inorganic (sorbent trap) samples were delivered to PNL on chain of custody (COC) 008071. The SUMMA{trademark} canisters were delivered on COC 008070. Three SUMMA{trademark} canister samples were stored at the PNL 326/23B laboratory pending further instruction from WHC to send them to the Oregon Graduate Institute (OGI) for analysis.

  13. Vapor space characterization of waste tank 241-C-109: Results from samples collected on 8/10/94

    SciTech Connect

    Pool, K.H.; Clauss, T.W.; Ligotke, M.W.

    1995-06-01

    This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-C-109 (referred to as Tank C-109). Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The sample job was designated S4053, and samples were collected by WHC on August 10, 1994, using the vapor sampling system (VSS). Sampling devices, including six sorbent trains (for inorganic analyses) and five SUMMA{sup {trademark}} canisters (for organic analyses) were supplied to the WHC sampling staff on August 8. Samples were taken (by WHC) from the tank headspace on August 10 and were returned to PNL from the field on August 12. The samples were inspected upon delivery to the 326/23B laboratory and logged into PNL record book 55408 before implementation of PNL Technical Procedure PNL-TVP-07. Custody of the sorbent traps was transferred to PNL personnel performing the inorganic analysis and stored at refrigerated ({<=}10{degrees}C) temperature until the time of analysis. The canister was stored in the 326/23B laboratory at ambient (25{degrees}C) temperature until time of analysis. Access to the 326/23B laboratory is limited to PNL personnel working on the waste-tank safety program. Analyses described in this report were performed at PNL in the 300 area of the Hanford Reservation. Analytical methods that were used are described in the text. In summary, sorbent traps for inorganic analyses containing sample materials were either weighed (for water analysis) or desorbed with the appropriate aqueous solutions (for ammonia (NH{sub 3}) or nitrite (NO{sub 2}) analyses). The aqueous extracts were analyzed either by selective electrode or by ion chromatography (IC). Organic analyses were performed using cryogenic preconcentration followed by gas chromatography/mass spectrometry (GC/MS).

  14. Do Milk Samples Stored for 12 Days after Collection Exhibit a Change in Composition Related to the Initial Bacterial Load?

    PubMed

    de Freitas, Larissa Nazareth; Cassoli, Laerte Dagher; da Silva, Janielen; de Figueiredo Pantoja, José Carlos; Machado, Paulo Fernando

    2016-05-01

    Total bacterial count (TBC) is a tool used to assess milk quality and is associated with not only the initial sample contamination but also the sample storage time and temperature. Several countries have reported milk samples with a high TBC, and the influence of TBC on milk preservation remains unclear. Thus, the aim of this study was to evaluate the impact of the initial bacterial contamination level on the macrocomponents and somatic cell count (SCC) of raw milk samples preserved with bronopol and maintained at two storage temperatures (7 and 25°C) for up to 12 days. Thus, we collected milk samples from 51 dairy farms, which were divided into two groups according to the initial bacterial load: low TBC (<100,000 CFU/ml) and high TBC (≥100,000 CFU/ml). We analyzed the sample composition for protein, fat, total solids, lactose, milk urea nitrogen, and the SCC. We did not observe an effect from TBC and storage time and temperature on the concentration of protein, fat, total solids, and lactose. SCC changes were not observed for samples maintained under refrigeration (7°C); however, samples maintained at room temperature (25°C) exhibited a decrease in the SCC beginning on day 6 of storage. For milk urea nitrogen, values increased when the samples were maintained at room temperature, beginning on the ninth storage day. Samples with the preservative bronopol added and maintained under refrigeration may be analyzed up to 12 days after collection, regardless of the milk microbial load. PMID:27296431

  15. Sample collection and preparation of biofluids and extracts for NMR spectroscopy.

    PubMed

    Le Gall, Gwénaëlle

    2015-01-01

    Metabonomics is a cross-disciplinary science that overlaps with analytical chemistry, biology, and statistical analysis. The techniques commonly used are proton nuclear magnetic resonance ((1)H NMR) spectroscopy and mass spectrometry (MS). Applying (1)H NMR on cell extracts provides a rapid and comprehensive screening of the most abundant metabolites allowing the quantitation of typically 20-70 compounds (depending on the type of sample) including amino and organic acids, sugars, amines, nucleosides, phenolic compounds, osmolytes, and lipids produced at sublevel millimolar concentrations. The sample preparation is usually kept minimal making the method particularly suited to high-throughput analysis (up to 100 samples/24 h with the use of a 60-holder autosampler). This chapter describes procedures for profiling liquids and solids of biological origin from plants, food, microbes, and mammalian systems. PMID:25677143

  16. Optimization of liquid scintillation measurements applied to smears and aqueous samples collected in industrial environments

    NASA Astrophysics Data System (ADS)

    Chapon, Arnaud; Pigrée, Gilbert; Putmans, Valérie; Rogel, Gwendal

    Search for low-energy β contaminations in industrial environments requires using Liquid Scintillation Counting. This indirect measurement method supposes a fine control from sampling to measurement itself. Thus, in this paper, we focus on the definition of a measurement method, as generic as possible, for both smears and aqueous samples' characterization. That includes choice of consumables, sampling methods, optimization of counting parameters and definition of energy windows, using the maximization of a Figure of Merit. Detection limits are then calculated considering these optimized parameters. For this purpose, we used PerkinElmer Tri-Carb counters. Nevertheless, except those relative to some parameters specific to PerkinElmer, most of the results presented here can be extended to other counters.

  17. Comparative genetic activity of samples collected from two different urban waste incinerators

    SciTech Connect

    Vellosi, R.; Galli, A.; Rossi, F.; Morichetti, E.; Bronzetti, G.

    1988-09-01

    Incineration of industrial and urban waste materials is an important problem for the environmental contamination and therefore for human health. Environmental contaminants spread by urban incinerators can contain a complex mixture of toxic compounds such as dioxin, benzofurans, alogenate acids. It is important to evaluate the genetic damage induced by complex mixtures widespread in the environment. In the present work, the genotoxic activity of samples obtained from the urban incinerator of Florence was analyzed. The results were compared with those obtained with samples drawn from the urban Snamprogetti incinerator of Schio (Vicenza), where halogenated acids contained in the smoke are neutralized with the lime wash in a salification column. Samples were tested using prokaryotic (Salmonella typhimurium TA98, TA100 and TA102 strains) and eukaryotic (Saccharomyces cerevisiae, D7 strain) microorganisms. These systems permit one to obtain rapid, reproducible and reliable results in order to evaluate the genotoxic activity of substances present in the environment.

  18. Hematologic Assessment in Pet Rats, Mice, Hamsters, and Gerbils: Blood Sample Collection and Blood Cell Identification.

    PubMed

    Lindstrom, Nicole M; Moore, David M; Zimmerman, Kurt; Smith, Stephen A

    2015-09-01

    Hamsters, gerbils, rats, and mice are presented to veterinary clinics and hospitals for prophylactic care and treatment of clinical signs of disease. Physical examination, history, and husbandry practice information can be supplemented greatly by assessment of hematologic parameters. As a resource for veterinarians and their technicians, this article describes the methods for collection of blood, identification of blood cells, and interpretation of the hemogram in mice, rats, gerbils, and hamsters.

  19. Curating NASA's Future Extraterrestrial Sample Collections: How Do We Achieve Maximum Proficiency?

    NASA Technical Reports Server (NTRS)

    McCubbin, Francis; Evans, Cynthia; Zeigler, Ryan; Allton, Judith; Fries, Marc; Righter, Kevin; Zolensky, Michael

    2016-01-01

    The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10E "Curation of Extraterrestrial Materials", JSC is charged with "The curation of all extraterrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "... documentation, preservation, preparation, and distribution of samples for research, education, and public outreach." Here we describe some of the ongoing efforts to ensure that the future activities of the NASA Curation Office are working towards a state of maximum proficiency.

  20. Recovery of a fish pathogenic bacterium, Aeromonas salmonicida, from ebonyshell mussels Fusconaia ebena using nondestructive sample collection procedures

    USGS Publications Warehouse

    Starliper, C.E.

    2008-01-01

    Refugia are increasingly being used to maintain and propagate imperiled freshwater mussels for future population augmentations. Success for this endeavor is dependent on good husbandry, including a holistic program of resource health management. A significant aspect to optimal health is the prevention or control of infectious diseases. Describing and monitoring pathogens and diseases in mussels involves examination of tissues or samples collected from an appropriate number of individuals that satisfies a certain confidence level for expected prevalences of infections. In the present study, ebonyshell mussels Fusconaia ebena were infected with a fish pathogenic bacterium, Aeromonas salmonicida, through their cohabitation with diseased brook trout Salvelinus fontinalis. At a 100% prevalence of infection, the F. ebena were removed from the cohabitation tank to clean tanks that were supplied with pathogen-free water, which initiated their depuration of A. salmonicida. Three samples (nondestructive fluid, mantle, hemolymph) collected using nondestructive procedures were compared with fluids and soft tissue homogenates collected after sacrificing the mussels for recovery of the bacterium during this period of depuration. Nondestructive sample collections, especially ND fluid, provide a comparable alternative to sacrificing mussels to determine pathogen status.

  1. Vapor space characterization of waste tank 241-C-101: Results from samples collected on 9/1/94

    SciTech Connect

    Lucke, R.B.; Clauss, T.W.; Ligotke, M.W.

    1995-11-01

    This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-C-101 (referred to as Tank C-101) and the ambient air collected - 30 ft upwind near the tank and through the VSS near the tank. Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The sample job was designated S4056, and samples were collected by WHC on September 1, 1994, using the vapor sampling system (VSS). The samples were inspected upon delivery to the 326/23B laboratory and logged into PNL record book 55408 before implementation of PNL Technical Procedure PNL-TVP-07. Custody of the sorbent traps was transferred to PNL personnel performing the inorganic analysis and stored at refrigerated ({le} 10{degrees}C) temperature until the time of analysis. The canisters were stored in the 326/23B laboratory at ambient (25{degrees}C) temperature until the time of the analysis. Access to the 326/23B laboratory is limited to PNL personnel working on the waste-tank safety program. Analyses described in this report were performed at PNL in the 300 area of the Hanford Reservation. Analytical methods that were used are described in the text. In summary, sorbent traps for inorganic analyses containing sample materials were either weighed (for water analysis) or desorbed with the appropriate aqueous solutions (for NH{sub 3}, NO{sub 2}, and NO analyses). The aqueous extracts were analyzed either by selective electrode or by ion chromatography (IC). Organic analyses were performed using cryogenic preconcentration followed by gas chromatography/mass spectrometry (GC/MS).

  2. Potential and Challenges in Collecting Social and Behavioral Data on Adolescent Alcohol Norms: Comparing Respondent-Driven Sampling and Web-Based Respondent-Driven Sampling

    PubMed Central

    Hildebrand, Janina; Burns, Sharyn; Zhao, Yun; Lobo, Roanna; Howat, Peter; Allsop, Steve

    2015-01-01

    Background Respondent-driven sampling (RDS) is a method successfully used to research hard-to-access populations. Few studies have explored the use of the Internet and social media with RDS, known as Web-based RDS (WebRDS). This study explored the use of combining both “traditional” RDS and WebRDS to examine the influences on adolescent alcohol use. Objective This paper reports on the recruitment processes and the challenges and enablers of both RDS and WebRDS. It details comparative recruitment data and provides a summary of the utility of both methods for recruiting adolescents to participate in an online survey investigating youth alcohol norms. Methods Process evaluation data collected from research staff throughout the study were used to assess the challenges and solutions of RDS and WebRDS. Pearson chi-square test (Fisher’s exact test if applicable) was used to compare the differences in sociodemographics and drinking behavior between data collected by RDS and WebRDS. Results Of the total sample (N=1012), 232 adolescents were recruited by RDS and 780 by WebRDS. A significantly larger proportion of Aboriginal or Torres Strait Islander (P<.001) participants who spoke English as their main language at home (P=.03), and of middle and lower socioeconomic status (P<.001) was found in the RDS sample. The RDS sample was also found to have a higher occurrence of past 7-day drinking (P<.001) and past 7-day risky drinking (P=.004). No significant differences in gender, age, past month alcohol use, and lifetime alcohol use were observed between the RDS and WebRDS samples. This study revealed RDS and WebRDS used similar lengths of chains for recruiting participants; however, WebRDS conducted a faster rate of recruitment at a lower average cost per participant compared to RDS. Conclusions Using WebRDS resulted in significant improvements in the recruitment rate and was a more effective and efficient use of resources than the traditional RDS method. However, Web

  3. SOURCES OF VARIABILITY IN COLLECTION AND PREPARATION OF PAINT AND LEAD-COATING SAMPLES

    EPA Science Inventory

    Chronic exposure of children to lead can result in permanent physiologic impairment. Since surfaces coated with lead-containing paints and varnishes are potential sources of exposure, it is extremely important that reliable methods for sampling and analysis be available. The so...

  4. COLLECTION OF AMBIENT PARTICULATE MATTER BY POROUS VEGETATION BARRIERS: SAMPLING AND CHARACTERIZATION METHODS

    EPA Science Inventory

    This manuscript describes work done by A. Reff as part of a collaboration begun 3 years ago at Rutgers University with A. Tiwary who was then at the University of Nottingham. The work describes sampling and characterization methods for investigating the effects of vegetative bar...

  5. Forage nutritive value of plant samples collected by clipping or rumen evacuation

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Knowing nutritive value and intake of forage by an animal is important to understand methane production data from individual animals in a grazed environment. Digestibility of forages is typically evaluated as the in vitro dry matter disappearance (IVDMD) using a clipped forage sample; however, beef...

  6. 21 CFR 111.80 - What representative samples must you collect?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... unique lot within each unique shipment); (b) Representative samples of in-process materials for each... manufacturing record where control is necessary to ensure the identity, purity, strength, and composition of....80 Section 111.80 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND...

  7. 75 FR 79033 - Proposed Extension of Existing Information Collection; Radiation Sampling and Exposure Records...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-17

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF LABOR Mine... Sampling and Exposure Records (Pertains to Underground Metal and Nonmetal Mines) AGENCY: Mine Safety and... assessed. Currently, the Mine Safety and Health Administration (MSHA) is soliciting comments concerning...

  8. Sampling Participants’ Experience in Laboratory Experiments: Complementary Challenges for More Complete Data Collection

    PubMed Central

    McAuliffe, Alan; McGann, Marek

    2016-01-01

    Speelman and McGann’s (2013) examination of the uncritical way in which the mean is often used in psychological research raises questions both about the average’s reliability and its validity. In the present paper, we argue that interrogating the validity of the mean involves, amongst other things, a better understanding of the person’s experiences, the meaning of their actions, at the time that the behavior of interest is carried out. Recently emerging approaches within Psychology and Cognitive Science have argued strongly that experience should play a more central role in our examination of behavioral data, but the relationship between experience and behavior remains very poorly understood. We outline some of the history of the science on this fraught relationship, as well as arguing that contemporary methods for studying experience fall into one of two categories. “Wide” approaches tend to incorporate naturalistic behavior settings, but sacrifice accuracy and reliability in behavioral measurement. “Narrow” approaches maintain controlled measurement of behavior, but involve too specific a sampling of experience, which obscures crucial temporal characteristics. We therefore argue for a novel, mid-range sampling technique, that extends Hurlburt’s descriptive experience sampling, and adapts it for the controlled setting of the laboratory. This controlled descriptive experience sampling may be an appropriate tool to help calibrate both the mean and the meaning of an experimental situation with one another. PMID:27242588

  9. Field geologic observation and sample collection strategies for planetary surface exploration: Insights from the 2010 Desert RATS geologist crewmembers

    NASA Astrophysics Data System (ADS)

    Hurtado, José M.; Young, Kelsey; Bleacher, Jacob E.; Garry, W. Brent; Rice, James W.

    2013-10-01

    Observation is the primary role of all field geologists, and geologic observations put into an evolving conceptual context will be the most important data stream that will be relayed to Earth during a planetary exploration mission. Sample collection is also an important planetary field activity, and its success is closely tied to the quality of contextual observations. To test protocols for doing effective planetary geologic fieldwork, the Desert RATS (Research and Technology Studies) project deployed two prototype rovers for two weeks of simulated exploratory traverses in the San Francisco volcanic field of northern Arizona. The authors of this paper represent the geologist crewmembers who participated in the 2010 field test. We document the procedures adopted for Desert RATS 2010 and report on our experiences regarding these protocols. Careful consideration must be made of various issues that impact the interplay between field geologic observations and sample collection, including time management; strategies related to duplication of samples and observations; logistical constraints on the volume and mass of samples and the volume/transfer of data collected; and paradigms for evaluation of mission success. We find that the 2010 field protocols brought to light important aspects of each of these issues, and we recommend best practices and modifications to training and operational protocols to address them. Underlying our recommendations is the recognition that the capacity of the crew to "flexibly execute" their activities is paramount. Careful design of mission parameters, especially field geologic protocols, is critical for enabling the crews to successfully meet their science objectives.

  10. Environmental radiation levels in soil and sediment samples collected from floating water from a land runway resulting from heavy rains in the Jeddah region, KSA

    NASA Astrophysics Data System (ADS)

    Mohery, M.; Baz, Shadiah; Kelany, Adel M.; Abdallah, A. M.

    2014-04-01

    The natural radiation levels in soil and sediment samples collected from floating water from a land runway resulting from heavy rains in the Jeddah region as well as the activity in the population of its surrounding environments were studied. In the regions surrounding Jeddah, the movements of floating water may increase the concentration of radioactivity due to the movement of soil due to heavy rains. In addition, the technological development of industry, agriculture and other sources around the Jeddah region has increased environmental pollution, resulting in noticeable concentrations of radioactivity. The measured activity concentrations of 214Pb, 214Bi, 228Ac, 208Tl, 40K, 226Ra and 228Ra in the studied area suggest that they are within the world average for soils and sediments, except those for water sample no. 4; the concentration in this sample was five times higher than the world average concentration (this water is not consumable). Herein, the radioactivity concentrations that were obtained from the analysis of soil and sediment samples that were collected from the investigated area are discussed. Additionally, the absorbed dose rate (D), radium equivalent activity (Raeq), external hazard index (Hex), annual gonadal dose equivalent (AGDE) and annual effective dose equivalent (AEDE) were evaluated. For the soil and sediment samples, the average radioactivity concentrations were determined for each site and are expressed in Becquerels per kilogram (Bq/kg) of dry weight, while for the measurement of both the 226Ra and 228Ra isotopes in the water samples, the activity concentration is expressed in picoCuries per liter (pCi/l). The obtained results were compared with other measurements from different countries. The movement of floating water around the Jeddah region increases the concentration of radioactivity due to the movement of soils with heavy rains.

  11. Methods for collection and analysis of aquatic biological and microbiological samples

    USGS Publications Warehouse

    Britton, Linda J., (Edited By); Greeson, Phillip E.

    1989-01-01

    Chapter A4 contains methods used by the U.S. Geological Survey to collect, preserve, and analyze water to determine its biological and microbiological properties. Part 1 consists of detailed descriptions of more than 45 individual methods, including those for bacteria, phytoplankton, zooplankton, seston, periphyton, macrophytes, benthic invertebrates, fish and other vertebrates, cellular contents, productivity, and bioassays. Each method is summarized, and the applications, interferences, apparatus, reagents, analyses, calculations, reporting of results, precisions, and references are given. Part 2 consists of a glossary. Part 3 is a list of taxonomic references.

  12. Elemental Compositions of Comet 81P/Wild 2 Samples Collected by Stardust

    NASA Technical Reports Server (NTRS)

    Flynn, G. J.; Bleuet, P.; Borg, J.; Bradley, J.; Brenker, F.; Brennan, S.; Bridges, J.; Brownlee, D. E.; Bullock, E.; Clark, B. C.; Papanastassiou, D. A.; Schwandt, C. S.; See, T. H.; Taylor, S.; Tsou, P.

    2006-01-01

    We measured the chemical compositions of material from 23 particles in aerogel and residue in 7 craters in aluminum foil, collected during passage of the Stardust spacecraft through the coma of Comet 81P/Wild 2. These particles are chemically heterogeneous at the largest size-scale analyzed, 180 nanograms. The mean chemical composition of this Wild 2 material agrees with the CI meteorite composition for the refractory elements Mg, Si, Cr, Fe, and Ni to 35%, and for Ca and Mn to 50%. The data suggest the moderately volatile elements Cu, Zn, and Ga may be enriched in this Wild 2 material.

  13. [Detection of Avian Influenza Virus in Environmental Samples Collected from Live Poultry Markets in China during 2009-2013].

    PubMed

    Zhang, Ye; Li, Xiaodan; Zou, Shumei; Bo, Hong; Dong, Libo; Gao, Rongbao; Wang, Dayan; Shu, Yuelong

    2015-11-01

    Abstract: To investigate the distribution of avian influenza virus in environmental samples from live poultry markets (LPM) in China, samples were collected and tested by nucleic acid during 2009-2013 season. Each sample was tested by real-time RT PCR using flu A specific primers. If any real-time PCR was positive, the sample was inoculated into specific-pathogen-free (SPF) embryonated chicken eggs for viral isolation. The results indicated that the positive rate of nucleic acid in enviromental samples exhibited seasonality. The positive rate of nucleic acid was significantly higher in Winter and Spring. The positive rate of nucleic acid in LPM located in the south of China was higher than in northern China. Samples of Sewage for cleaning poultry and chopping board showed that higher positive rate of nucleic acid than other samples. The Subtype identification showed that H5 and H9 were main subtypes in the enviromental samples. Viral isolation indicated H5 subtypes was more than H9 subtypes between 2009 and 2013 while H9 subtypes increased in 2013. Our findings suggested the significance of public health based on LPM surveillance and provided the basis of prevention and early warning for avian flu infection human. PMID:26951005

  14. The post-occipital spinal venous sinus of the Nile crocodile Crocodylus niloticus: its anatomy and use for blood sample collection and intravenous infusions.

    PubMed

    Myburgh, Jan G; Kirberger, Robert M; Steyl, Johan C A; Soley, John T; Booyse, Dirk G; Huchzermeyer, Fritz W; Lowers, Russel H; Guillette, Louis J

    2014-05-05

    The post-occipital sinus of the spinal vein is often used for the collection of blood samples from crocodilians. Although this sampling method has been reported for several crocodilian species, the technique and associated anatomy has not been described in detail in any crocodilian, including the Nile crocodile (Crocodylus niloticus). The anatomy of the cranial neck region was investigated macroscopically, microscopically, radiographically and by means of computed tomography. Latex was injected into the spinal vein and spinal venous sinus of crocodiles to visualise the regional vasculature. The spinal vein ran within the vertebral canal, dorsal to and closely associated with the spinal cord and changed into a venous sinus cranially in the post-occipital region. For blood collection, the spinal venous sinus was accessed through the interarcuate space between the atlas and axis (C1 and C2) by inserting a needle angled just off the perpendicular in the midline through the craniodorsal cervical skin, just cranial to the cranial borders of the first cervical osteoderms. The most convenient method of blood collection was with a syringe and hypodermic needle. In addition, the suitability of the spinal venous sinus for intravenous injections and infusions in live crocodiles was evaluated. The internal diameter of the commercial human epidural catheters used during these investigations was relatively small, resulting in very slow infusion rates. Care should be taken not to puncture the spinal cord or to lacerate the blood vessel wall using this route for blood collection or intravenous infusions.

  15. Swine gene banking: a quality control perspective on collection, and analysis of samples for a national repository.

    PubMed

    Purdy, Phillip H

    2008-11-01

    The National Animal Germplasm Program (NAGP) is developing a national repository for germplasm (semen, oocytes, embryos, blood, DNA, tissue) for all agricultural species in the US. Currently, the swine collection consists of 127,479 samples from 886 boars representing 20 major, minor and composite populations. Cryopreservation per se is not an impediment to program success. Rather, the greatest difficulties encountered are in determining the quality of the samples pre- and post-thaw. Robust, broadly applicable, and cost effective quality control methodologies need to be developed and implemented. This overview of the NAGP will discuss the approaches used for cryopreserving boar semen samples, overcoming the challenges of assessing sample quality, and moving toward a quality control strategy. PMID:18640707

  16. Detection of Arcobacter spp. in Mytilus galloprovincialis Samples Collected from Apulia Region

    PubMed Central

    Bonerba, Elisabetta; Parisi, Antonio; Di Pinto, Angela; Serraino, Andrea; Bozzo, Giancarlo; Giacometti, Federica; Ceci, Edmondo; Tantillo, Giuseppina

    2015-01-01

    The aim of the study was to evaluate the occurrence of Arcobacter spp. in 20 samples of Mytilus galloprovincialis purchased at fish markets in Apulia region. The detection of Arcobacter spp. was performed, after selective enrichment, on modified charcoal cefoperazone deoxycholate (mCCD) agar supplemented with Cefoperazone, Amphotericin B and Teicoplanin (CAT). In 6 out of the 20 tested samples the presence of Arcobacter spp. was found and confirmed by genus-based polymerase chain reaction. All the isolates were identified as belonging to the species Arcobacter butzleri using 16S rDNA sequencing and BLAST online. The results represent the first report in Italy of A. butzleri detection in marketed Mytilus galloprovincialis. The survey underlines the epidemiological importance of A. butzleri as an emerging pathogen, and highlights that mussels should be considered as a potential cause of foodborne disease outbreak. PMID:27800382

  17. Calculation of Collective Variable-based PMF by Combining WHAM with Umbrella Sampling

    NASA Astrophysics Data System (ADS)

    Xu, Wei-Xin; Li, Yang; Zhang, John Z. H.

    2012-06-01

    Potential of mean force (PMF) with respect to localized reaction coordinates (RCs) such as distance is often applied to evaluate the free energy profile along the reaction pathway for complex molecular systems. However, calculation of PMF as a function of global RCs is still a challenging and important problem in computational biology. We examine the combined use of the weighted histogram analysis method and the umbrella sampling method for the calculation of PMF as a function of a global RC from the coarse-grained Langevin dynamics simulations for a model protein. The method yields the folding free energy profile projected onto a global RC, which is in accord with benchmark results. With this method rare global events would be sufficiently sampled because the biased potential can be used for restricting the global conformation to specific regions during free energy calculations. The strategy presented can also be utilized in calculating the global intra- and intermolecular PMF at more detailed levels.

  18. Prevalence of L. Monocytogenes in Environmental Samples Collected in Dairy Plants of Sassari Province, Italy

    PubMed Central

    Fadda, Antonio; Frongia, Giorgio; Sanna, Antonietta; Melillo, Rita

    2015-01-01

    Listeria (L.) monocytogenes is frequently isolated from food production environment and often persists in dairy plants despite vigorous sanitation regimes. In recent years several alert notifications were sent to Rapid Alert System for Food Products system as a consequence of Listeria monocytogenes contamination of ricotta cheese. After the alert of 2012, competent authority (Local Health Unit of Sassari Province) organised an environmental monitoring plan with the partnership of the Institute for Experimental Veterinary Medicine of Sardinia to verify analysis of dairy plants own-check according to Regulation (EC) N° 2073/05 and further modifications. In 2014 n. 665 processing areas samples of n. 50 dairy plants of Sassari Province were examined. UNI EN ISO 11290-1:2005 for detection of L. monocytogenes was used. Non-compliance in n. 5 diary plants are observed (n. 8 positive samples). Post-non-compliance environmental sanitisation was efficient and own-check plans included appropriate corrective actions. PMID:27800407

  19. A horizontal sampler for collection of water samples near the bottom

    USGS Publications Warehouse

    Joeris, Leonard S.

    1964-01-01

    The need to obtain adequate water samples immediately above a lake bottom or at a precisely defined depth is not new. The problem is of particular concern in a large section of central Lake Erie, where dissolved oxygen concentration may be reduced to 1 ppm or less in the hypolimnion and where the metalimnion frequently extends to or within 30 or 60 cm of the bottom (Becton 1963; Cam 1962).It is impossible to sample the hypolimnrtic waters satisfactorily with the usual Nanscn, Kemmerer, and Frautschy bottles (Carr 1962). Although the 500-ml sampler described here was designed, constructed, and used extensively and successfully to meet the particular problem in Lake Erie, it should be equally useful in a varirty of situations.

  20. Intercomparison of elemental concentrations in total and size-fractionated aerosol samples collected during the mace head experiment, April 1991

    NASA Astrophysics Data System (ADS)

    François, Filip; Maenhaut, Willy; Colin, Jean-Louis; Losno, Remi; Schulz, Michael; Stahlschmidt, Thomas; Spokes, Lucinda; Jickells, Timothy

    During an intercomparison field experiment, organized at the Atlantic coast station of Mace Head, Ireland, in April 1991, aerosol samples were collected by four research groups. A variety of samplers was used, combining both high- and low-volume devices, with different types of collection substrates: Hi-Vol Whatman 41 filter holders, single Nuclepore filters and stacked filter units, as well as PIXE cascade impactors. The samples were analyzed by each participating group, using in-house analytical techniques and procedures. The intercomparison of the daily concentrations for 15 elements, measured by two or more participants, revealed a good agreement for the low-volume samplers for the majority of the elements, but also indicated some specific analytical problems, owing to the very low concentrations of the non-sea-salt elements at the sampling site. With the Hi-Vol Whatman 41 filter sampler, on the other hand, much higher results were obtained in particular for the sea-salt and crustal elements. The discrepancy was dependent upon the wind speed and was attributed to a higher collection efficiency of the Hi-Vol sampler for the very coarse particles, as compared to the low-volume devices under high wind speed conditions. The elemental mass size distribution, as derived from parallel cascade impactor samplings by two groups, showed discrepancies in the submicrometer aerosol fraction, which were tentatively attributed to differences in stage cut-off diameters and/or to bounce-off or splintering effects on the quartz impactor slides used by one of the groups. However, the atmospheric concentrations (sums over all stages) were rather similar in the parallel impactor samples and were only slightly lower than those derived from stacked filter unit samples taken in parallel.

  1. Evaluation of surface sampling techniques for collection of Bacillus spores on common drinking water pipe materials.

    PubMed

    Packard, Benjamin H; Kupferle, Margaret J

    2010-01-01

    Drinking water utilities may face biological contamination of the distribution system from a natural incident or deliberate contamination. Determining the extent of contamination or the efficacy of decontamination is a challenge, because it may require sampling of the wetted surfaces of distribution infrastructure. This study evaluated two sampling techniques that utilities might use to sample exhumed pipe sections. Polyvinyl chloride (PVC), cement-lined ductile iron, and ductile iron pipe coupons (3 cm x 14 cm) cut from new water main piping were conditioned for three months in dechlorinated Cincinnati, Ohio tap water. Coupons were spiked with Bacillus atrophaeus subsp. globigii, a surrogate for Bacillus anthracis. Brushing and scraping were used to recover the inoculated spores from the coupons. Mean recoveries for all materials ranged from 37 +/- 30% to 43 +/- 20% for brushing vs. 24 +/- 10% to 51 +/- 29% for scraping. On cement-lined pipe, brushing yielded a significantly different recovery than scraping. No differences were seen between brushing and scraping the PVC and iron pipe coupons. Mean brushing and scraping recoveries from PVC coupons were more variable than mean recoveries from cement-lined and iron coupons. Spore retention differed between pipe materials and the presence of established biofilms also had an impact. Conditioned PVC coupons (with established biofilms) had significantly lower spore retention (31 +/- 11%) than conditioned cement-lined coupons (61 +/- 14%) and conditioned iron coupons (71 +/- 8%).

  2. Biological sample collections from minors for genetic research: a systematic review of guidelines and position papers

    PubMed Central

    Hens, Kristien; Nys, Herman; Cassiman, Jean-Jacques; Dierickx, Kris

    2009-01-01

    Stored tissue samples are an important resource for epidemiological genetic research. Genetic research on biological material from minors can yield valuable information on the development and genesis of early-onset genetic disorders and the early interaction of environmental and genetic factors. The use of such tissue raises some specific ethical and governance questions, which are not completely covered by the discussion on biological materials from adults. We have retrieved 29 guidelines and position papers pertaining to the storage and use of biological tissue samples for genetic research, originating from 27 different organizations. Five documents have an international scope, three have an European scope and 21 have a national scope. We discovered that 11 of these documents did not contain a section on biological materials from minors. The content of the remaining 18 documents was categorized according to four themes: consent, principles of non-therapeutic research on vulnerable populations, ethics committee approval and difference between anonymous and identifiable samples. We found out that these themes are not consistently mentioned by each document, but that documents discussing the same themes were mostly in agreement with their recommendations. However, a systematic reflection on the ethical and policy issues arising from the participation of minors in biobank research is missing. PMID:19223929

  3. Comparison of Results for Quarter 1 Surface Water Split Samples Collected at the Nuclear Fuel Services Site, Erwin, Tennessee

    SciTech Connect

    David A. King, CHP, PMP

    2012-10-10

    Oak Ridge Associated Universities (ORAU), under the Oak Ridge Institute for Science and Education (ORISE) contract, collected split surface water samples with Nuclear Fuel Services (NFS) representatives on August 22, 2012. Representatives from the U.S. Nuclear Regulatory Commission and Tennessee Department of Environment and Conservation were also in attendance. Samples were collected at four surface water stations, as required in the approved Request for Technical Assistance number 11-018. These stations included Nolichucky River upstream (NRU), Nolichucky River downstream (NRD), Martin Creek upstream (MCU), and Martin Creek downstream (MCD). Both ORAU and NFS performed gross alpha and gross beta analyses. The comparison of results using the duplicate error ratio (DER), also known as the normalized absolute difference. A DER ≤ 3 indicates that, at a 99% confidence interval, split sample results do not differ significantly when compared to their respective one standard deviation (sigma) uncertainty. The NFS split sample report does not specify the confidence level of reported uncertainties. Therefore, standard two sigma reporting is assumed and uncertainty values were divided by 1.96. A comparison of split sample results, using the DER equation, indicates one set with a DER greater than 3. A DER of 3.1 is calculated for gross alpha results from ORAU sample 5198W0003 and NFS sample MCU-310212003. The ORAU result is 0.98 ± 0.30 pCi/L (value ± 2 sigma) compared to the NFS result of -0.08 ± 0.60 pCi/L. Relatively high DER values are not unexpected for low (e.g., background) analyte concentrations analyzed by separate laboratories, as is the case here. It is noted, however, NFS uncertainties are at least twice the ORAU uncertainties, which contributes to the elevated DER value. Differences in ORAU and NFS minimum detectable activities are even more pronounced. comparison of ORAU and NFS split samples produces reasonably consistent results for low (e.g., background

  4. Assessment of selected contaminants in streambed- and suspended-sediment samples collected in Bexar County, Texas, 2007-09

    USGS Publications Warehouse

    Wilson, Jennifer T.

    2011-01-01

    Elevated concentrations of sediment-associated contaminants are typically associated with urban areas such as San Antonio, Texas, in Bexar County, the seventh most populous city in the United States. This report describes an assessment of selected sediment-associated contaminants in samples collected in Bexar County from sites on the following streams: Medio Creek, Medina River, Elm Creek, Martinez Creek, Chupaderas Creek, Leon Creek, Salado Creek, and San Antonio River. During 2007-09, the U.S. Geological Survey periodically collected surficial streambed-sediment samples during base flow and suspended-sediment (large-volume suspended-sediment) samples from selected streams during stormwater runoff. All sediment samples were analyzed for major and trace elements and for organic compounds including halogenated organic compounds and polycyclic aromatic hydrocarbons (PAHs). Selected contaminants in streambed and suspended sediments in watersheds of the eight major streams in Bexar County were assessed by using a variety of methods—observations of occurrence and distribution, comparison to sediment-quality guidelines and data from previous studies, statistical analyses, and source indicators. Trace elements concentrations were low compared to the consensus-based sediment-quality guidelines threshold effect concentration (TEC) and probable effect concentration (PEC). Trace element concentrations were greater than the TEC in 28 percent of the samples and greater than the PEC in 1.5 percent of the samples. Chromium concentrations exceeded sediment-quality guidelines more frequently than concentrations of any other constituents analyzed in this study (greater than the TEC in 69 percent of samples and greater than the PEC in 8 percent of samples). Mean trace element concentrations generally are lower in Bexar County samples compared to concentrations in samples collected during previous studies in the Austin and Fort Worth, Texas, areas, but considering the relatively

  5. An investigation into the concurrent collection of human scent and epithelial skin cells using a non-contact sampling device.

    PubMed

    Caraballo, Norma Iris; Mendel, Julian; Holness, Howard; La Salvia, Joel; Moroose, Tina; Eckenrode, Brian; Stockham, Rex; Furton, Kenneth; Mills, DeEtta

    2016-09-01

    In criminal investigations, the collection of human scent often employs a non-contact, dynamic airflow device, known as the Scent Transfer Unit 100 (STU-100), to transfer volatile organic compounds (VOCs) from an object/person onto a collection material that is subsequently presented to human scent discriminating canines. Human scent is theorized to be linked to epithelial skin cells that are shed at a relatively constant rate allowing both scent and cellular material to be deposited into the environment and/or onto objects. Simultaneous collection of cellular material, with adequate levels of nuclear deoxyribonucleic acid (nDNA), and human scent using a non-invasive methodology would facilitate criminal investigations. This study evaluated the STU-100 for the concurrent collection of human scent and epithelial skin cells from a porous (paper) and non-porous (stainless steel bar) object that was held for a specified period of time in the dominant hand of twenty subjects (10 females and 10 males). Human scent analysis was performed using headspace static solid-phase microextraction with gas chromatography-mass spectrometry (HS-SPME/GC-MS). A polycarbonate filter was used to trap epithelial skin cells which, upon extraction, were subsequently analyzed, inter-laboratory, using the quantitative polymerase chain reaction (qPCR). The STU-100 proved to be inadequate for collecting the minimum number of epithelial skin cells required to obtain nuclear DNA concentrations above the limit of detection for the qPCR kit. With regard to its use for human scent collection, a reduction in the number and mass of compounds was observed when compared to samples that were directly collected. However, when the indirect collection of human scent from the two different objects was compared, a greater number and mass of compounds was observed from the non-porous object than from the porous object. This outcome suggests that the matrix composition of the scent source could affect the

  6. An investigation into the concurrent collection of human scent and epithelial skin cells using a non-contact sampling device.

    PubMed

    Caraballo, Norma Iris; Mendel, Julian; Holness, Howard; La Salvia, Joel; Moroose, Tina; Eckenrode, Brian; Stockham, Rex; Furton, Kenneth; Mills, DeEtta

    2016-09-01

    In criminal investigations, the collection of human scent often employs a non-contact, dynamic airflow device, known as the Scent Transfer Unit 100 (STU-100), to transfer volatile organic compounds (VOCs) from an object/person onto a collection material that is subsequently presented to human scent discriminating canines. Human scent is theorized to be linked to epithelial skin cells that are shed at a relatively constant rate allowing both scent and cellular material to be deposited into the environment and/or onto objects. Simultaneous collection of cellular material, with adequate levels of nuclear deoxyribonucleic acid (nDNA), and human scent using a non-invasive methodology would facilitate criminal investigations. This study evaluated the STU-100 for the concurrent collection of human scent and epithelial skin cells from a porous (paper) and non-porous (stainless steel bar) object that was held for a specified period of time in the dominant hand of twenty subjects (10 females and 10 males). Human scent analysis was performed using headspace static solid-phase microextraction with gas chromatography-mass spectrometry (HS-SPME/GC-MS). A polycarbonate filter was used to trap epithelial skin cells which, upon extraction, were subsequently analyzed, inter-laboratory, using the quantitative polymerase chain reaction (qPCR). The STU-100 proved to be inadequate for collecting the minimum number of epithelial skin cells required to obtain nuclear DNA concentrations above the limit of detection for the qPCR kit. With regard to its use for human scent collection, a reduction in the number and mass of compounds was observed when compared to samples that were directly collected. However, when the indirect collection of human scent from the two different objects was compared, a greater number and mass of compounds was observed from the non-porous object than from the porous object. This outcome suggests that the matrix composition of the scent source could affect the

  7. Vapor space characterization of waste Tank 241-BY-111: Results from samples collected on November 15, 1994

    SciTech Connect

    Lucke, R.B.; Ligotke, M.W.; McVeety, B.D.

    1995-06-01

    This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-BY-111 (referred to as Tank By-111). Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The target analytes for TO- 14 compounds were extended to include 14 analytes identified by the Toxicological Review Panel for Tank C-103 and reported by Mahlum et al. (1994). Program management included these analytes for future tank analyses as identified in the fiscal year work plan. This plan is attached to a letter dated 9/30/94 and addressed to Mr. T.J. Kelly of WHC. The plan also requires PNL to analyze for the permanent gases as shown in Table 3.7. The sample job was designated S4083, and samples wee collected by WHC on November 16, 1994, using the vapor sampling system (VSS). The results of the analyses are expected to be used to estimate the potential toxicity of tank-headspace gas as described in Data Quality Objectives for Generic In-Tank Health and Safety Vapor Issue Resolution, WHC-SD-WM-DQO-002, Rev. 0.

  8. Sampling protocols for collecting surface water, bed sediment, bivalves, and fish for priority pollutant analysis. Final report

    SciTech Connect

    Not Available

    1982-05-28

    The U.S. Environmental Protection Agency, Office of Water Regulations and Standards, is conducting a program to evaluate exposure and associated risk from the presence of toxic pollutants in our nation's aquatic environment. The program addresses the goals of the Clean Water Act of 1977 by developing exposure profiles for the 129 priority pollutants. The sampling document describes procedures for collecting, preserving, and shipping samples that will be analyzed to provide information on ambient levels of the priority pollutants, which is an essential component of the data base necessary for characterizing exposure.

  9. Monitoring of sulphites levels in shrimps samples collected in Puglia (Italy) by ion-exchange chromatography with conductivity detection.

    PubMed

    Iammarino, Marco; Di Taranto, Aurelia; Ientile, Anna Rita

    2014-01-01

    In shrimps the treatment with sulphiting agents is currently the best option for controlling Melanosis, which is a visual defect of the products that compromises marketability. However, sulphites may cause pseudo-allergic reactions in humans. In this study, 210 samples of shrimps were analysed in order to assess the residual levels of sulphiting agents. A quantifiable sulphites concentration was detected in 76 samples, and these concentrations were higher than the legal limits in eight samples. Considering the important pseudo-allergenic effects caused by these food additives, the non-negligible percentage of 3.8% and the high levels registered in non-compliant samples (up to 1174.1 mg kg(-1)), a strong contrast action based on permanent controls is necessary. Moreover, the levels measured in whole samples were up to four times higher than in the edible parts. These results suggest to consider the introduction of legal limits, related to sulphurous anhydride in the whole product.

  10. Meteorites and Microbes: Meteorite Collection and Ice Sampling at Patriot Hills, Thiel Mountains, and South Pole, Antarctica

    NASA Technical Reports Server (NTRS)

    Sipiera, Paul P.; Hoover, Richard B.; Rose, M. Franklin (Technical Monitor)

    2000-01-01

    During the Antarctica 2000 Expedition, sponsored by the Planetary Studies Foundation, meteorites and ice microbiota were collected from the Patriot Hills, and Thiel Mountains of Antarctica and snow samples were at the South Pole. Psychrophilic and psychrotrophic microbiota were obtained from blue ice, cryoconite and ice-bubble systems. Twenty frozen meteorites were collected using aseptic techniques from the blue ice fields near the Moulton Escarpment of the Thiel Mountains (85 S, 94 W) and from the Morris Moraine of the Patriot Hills (80 S, 81 W) Ellsworth Mountains. These ice and meteorite samples are of potential significance to Astrobiology. They may help refine chemical and morphological biomarkers and refine characteristics of microbial life in one of the harshest environments on Earth. We discuss the Antarctica 2000 Expedition and provide preliminary results of the investigation of the meteorites and ice microbiota recovered.

  11. COMPARISON OF RESULTS FOR QUARTER 5 SURFACE WATER SPLIT SAMPLES COLLECTED AT THE NUCLEAR FUEL SERVICES SITE ERWIN TENNESSEE

    SciTech Connect

    2013-09-23

    Oak Ridge Associated Universities (ORAU), under the Oak Ridge Institute for Science and Education (ORISE) contract, collected split surface water samples with Nuclear Fuel Services (NFS) representatives on August 21, 2013. Representatives from the U.S. Nuclear Regulatory Commission (NRC) and the Tennessee Department of Environment and Conservation were also in attendance. Samples were collected at four surface water stations, as required in the approved Request for Technical Assistance number 11-018. These stations included Nolichucky River upstream (NRU), Nolichucky River downstream (NRD), Martin Creek upstream (MCU), and Martin Creek downstream (MCD). Both ORAU and NFS performed gross alpha and gross beta analyses, and the comparison of results using the duplicate error ratio (DER), also known as the normalized absolute difference, are tabulated. All DER values were less than 3 and results are consistent with low (e.g., background) concentrations.

  12. Geochemical data for core and bottom-sediment samples collected in 2007 from Grand Lake O' the Cherokees, northeast Oklahoma

    USGS Publications Warehouse

    Fey, David L.; Becker, Mark F.; and Smith, Kathleen S.

    2010-01-01

    Grand Lake O' the Cherokees is a large reservoir in northeast Oklahoma, below the confluence of the Neosho and Spring Rivers, both of which drain the Tri-State Mining District to the north. The Tri-State district covers an area of 1,200 mi2 (3,100 km2) and comprises Mississippi Valley-type lead-zinc deposits. A result of 120 years of mining activity is an estimated 75 million tons of processed mine tailings (chat) remaining in the district. Concerns of sediment quality and the possibility of human exposure to cadmium and lead through eating fish have led to several studies of the sediments in the Tri-State district. In order to record the transport and deposition of metals from the Tri-State district by the Spring and Neosho Rivers into Grand Lake O' the Cherokees, the U.S. Geological Survey collected 11 sediment cores and 15 bottom-sediment samples in September 2007. Subsamples from five selected cores and the bottom-sediment samples were analyzed for major and trace elements and forms of carbon. The sediment samples collected from the sediment-water interface had larger average concentrations of zinc, cadmium, and lead than local background. The core collected from the Spring River had the largest concentrations of mining-related elements. A core collected just south of Twin Bridges State Park, at the confluence of the Spring and Neosho Rivers, showed a mixing zone with more mining-related elements coming from the Spring River side. The element zinc showed the most definitive patterns in graphs depicting concentration-versus-depth profiles. A core collected from the main body of the reservoir showed affected sediment down to a depth of 85 cm (33 in). This core and two others appear to have penetrated to below mining-affected sediment.

  13. Elemental Compositions of Comet 81P/Wild 2 Samples Collected by Stardust

    SciTech Connect

    Flynn,G.; Bleuet, P.; Borg, J.; Bradley, J.; Brenker, F.; Brennan, S.; Bridges, J.; Brownlee, D.; Bullock, E.; et al.

    2006-01-01

    We measured the elemental compositions of material from 23 particles in aerogel and from residue in seven craters in aluminum foil that was collected during passage of the Stardust spacecraft through the coma of comet 81P/Wild 2. These particles are chemically heterogeneous at the largest size scale analyzed ({approx}180 ng). The mean elemental composition of this Wild 2 material is consistent with the CI meteorite composition, which is thought to represent the bulk composition of the solar system, for the elements Mg, Si, Mn, Fe, and Ni to 35%, and for Ca and Ti to 60%. The elements Cu, Zn, and Ga appear enriched in this Wild 2 material, which suggests that the CI meteorites may not represent the solar system composition for these moderately volatile minor elements.

  14. Elemental compositions of comet 81P/Wild 2 samples collected by Stardust.

    PubMed

    Flynn, George J; Bleuet, Pierre; Borg, Janet; Bradley, John P; Brenker, Frank E; Brennan, Sean; Bridges, John; Brownlee, Don E; Bullock, Emma S; Burghammer, Manfred; Clark, Benton C; Dai, Zu Rong; Daghlian, Charles P; Djouadi, Zahia; Fakra, Sirine; Ferroir, Tristan; Floss, Christine; Franchi, Ian A; Gainsforth, Zack; Gallien, Jean-Paul; Gillet, Philippe; Grant, Patrick G; Graham, Giles A; Green, Simon F; Grossemy, Faustine; Heck, Philipp R; Herzog, Gregory F; Hoppe, Peter; Hörz, Friedrich; Huth, Joachim; Ignatyev, Konstantin; Ishii, Hope A; Janssens, Koen; Joswiak, David; Kearsley, Anton T; Khodja, Hicham; Lanzirotti, Antonio; Leitner, Jan; Lemelle, Laurence; Leroux, Hugues; Luening, Katharina; Macpherson, Glenn J; Marhas, Kuljeet K; Marcus, Matthew A; Matrajt, Graciela; Nakamura, Tomoki; Nakamura-Messenger, Keiko; Nakano, Tsukasa; Newville, Matthew; Papanastassiou, Dimitri A; Pianetta, Piero; Rao, William; Riekel, Christian; Rietmeijer, Frans J M; Rost, Detlef; Schwandt, Craig S; See, Thomas H; Sheffield-Parker, Julie; Simionovici, Alexandre; Sitnitsky, Ilona; Snead, Christopher J; Stadermann, Frank J; Stephan, Thomas; Stroud, Rhonda M; Susini, Jean; Suzuki, Yoshio; Sutton, Stephen R; Taylor, Susan; Teslich, Nick; Troadec, D; Tsou, Peter; Tsuchiyama, Akira; Uesugi, Kentaro; Vekemans, Bart; Vicenzi, Edward P; Vincze, Laszlo; Westphal, Andrew J; Wozniakiewicz, Penelope; Zinner, Ernst; Zolensky, Michael E

    2006-12-15

    We measured the elemental compositions of material from 23 particles in aerogel and from residue in seven craters in aluminum foil that was collected during passage of the Stardust spacecraft through the coma of comet 81P/Wild 2. These particles are chemically heterogeneous at the largest size scale analyzed ( approximately 180 ng). The mean elemental composition of this Wild 2 material is consistent with the CI meteorite composition, which is thought to represent the bulk composition of the solar system, for the elements Mg, Si, Mn, Fe, and Ni to 35%, and for Ca and Ti to 60%. The elements Cu, Zn, and Ga appear enriched in this Wild 2 material, which suggests that the CI meteorites may not represent the solar system composition for these moderately volatile minor elements.

  15. Elemental composition of Comet 81P/Wild2 samples collected byStardust

    SciTech Connect

    Flynn, G.J.; Bleuet, P.; Borg, J.; Bradley, J.P.; Brenker, F.E.; Brennan, S.; Bridges, J.; Brownlee, D.E.; Bullock, E.S.; Burghammer,Manfred; Clark, B.C.; Dai, Zu Rong; Daghlian, C.P.; Djouadi, Z.; Fakra,S; Ferroir, T.; Floss, C.; Franchi, I.A.; Gainsforth, Z.; Gallien, J.P.; Gillet, P.; Grant, P.G.; Graham, G.A.; Green, S.F.; Grossemy, F.; Heck,P.R.; Herzog, G.F.; Hoppe, P.; Horz, F.; Huth, J.; Ignatyev, K.; Ishii,H.A.; Janssens, K.; Joswiak, D.; Kearsley, A.T.; Khodja, H.; Lanzirotti,A.; Leitner, J.; Lemelle, L.; Leroux, H.; Luening, K.; MacPherson, G.J.; Marhas, K.K.; Marcus, M.A.; Matrajt, G.; Nakamura, T.; Nakamura-Messenger, K.; Nakano, T.; Newville, M.; Papanastassiou, D.A.; Pianette, P.; Rao, William; Riekel, C.; Rietmeijer, F.J.M.; Rost, D.; Schwandt, C.S.; See, T.H.; Sheffield-Parker, J.; Simionovici, A.; Sitnitsky, Ilona; Snead, C.J.; Stadermann, F.J.; Stephan, T.; Stroud,R.M.; Susini, J.; Suzuki, Y.; Sutton, S.R.; Taylor, S.; Teslich, N.; Troadec, D.; Tsou, P.; Tsuchiyama, A.; Uesugi, K.; Vekemans, B.; Vicenzi,E.P.; Vincze, L.; Westphal, A.J.; Wozniakiewicz, P.; Zinner, E.; Zolensky, M.E.

    2006-01-01

    We measured the elemental compositions of material from 23 particles in aerogel and from residue in seven craters in aluminum foil that was collected during passage of the Stardust spacecraft through the coma of comet 81P/Wild 2. These particles are chemically heterogeneous at the largest size scale analyzed ({approx}180 ng). The mean elemental composition of this Wild 2 material is consistent with the CI meteorite composition, which is thought to represent the bulk composition of the solar system, for the elements Mg, Si, Mn, Fe, and Ni to 35%, and for Ca and Ti to 60%. The elements Cu, Zn, and Ga appear enriched in this Wild 2 material, which suggests that the CI meteorites may not represent the solar system composition for these moderately volatile minor elements.

  16. Sample handling and contamination encountered when coupling offline normal phase high performance liquid chromatography fraction collection of petroleum samples to Fourier transform ion cyclotron resonance mass spectrometry.

    PubMed

    Oro, Nicole E; Whittal, Randy M; Lucy, Charles A

    2012-09-01

    Normal phase high performance liquid chromatography (HPLC) is used to separate a gas oil petroleum sample, and the fractions are collected offline and analyzed on a high resolution Fourier Transform Ion Cyclotron Resonance Mass Spectrometer (FT-ICR MS). The separation prior to MS analysis dilutes the sample significantly; therefore the fractions need to be prepared properly to achieve the best signal possible. The methods used to prepare the HPLC fractions for MS analysis are described, with emphasis placed on increasing the concentration of analyte species. The dilution effect also means that contamination in the MS spectra needs to be minimized. The contamination from molecular sieves, plastics, soap, etc. and interferences encountered during the offline fraction collection process are described and eliminated. A previously unreported MS contamination of iron formate clusters with a 0.8 mass defect in positive mode electrospray is also described. This interference resulted from the stainless steel tubing in the HPLC system. Contamination resulting from what has tentatively been assigned as palmitoylglycerol and stearoylglycerol was also observed; these compounds have not previously been reported as contaminant peaks.

  17. Sample handling and contamination encountered when coupling offline normal phase high performance liquid chromatography fraction collection of petroleum samples to Fourier transform ion cyclotron resonance mass spectrometry.

    PubMed

    Oro, Nicole E; Whittal, Randy M; Lucy, Charles A

    2012-09-01

    Normal phase high performance liquid chromatography (HPLC) is used to separate a gas oil petroleum sample, and the fractions are collected offline and analyzed on a high resolution Fourier Transform Ion Cyclotron Resonance Mass Spectrometer (FT-ICR MS). The separation prior to MS analysis dilutes the sample significantly; therefore the fractions need to be prepared properly to achieve the best signal possible. The methods used to prepare the HPLC fractions for MS analysis are described, with emphasis placed on increasing the concentration of analyte species. The dilution effect also means that contamination in the MS spectra needs to be minimized. The contamination from molecular sieves, plastics, soap, etc. and interferences encountered during the offline fraction collection process are described and eliminated. A previously unreported MS contamination of iron formate clusters with a 0.8 mass defect in positive mode electrospray is also described. This interference resulted from the stainless steel tubing in the HPLC system. Contamination resulting from what has tentatively been assigned as palmitoylglycerol and stearoylglycerol was also observed; these compounds have not previously been reported as contaminant peaks. PMID:22840706

  18. Field Geologic Observation and Sample Collection Strategies for Planetary Surface Exploration: Insights from the 2010 Desert RATS Geologist Crewmembers

    NASA Technical Reports Server (NTRS)

    Hurtado, Jose M., Jr.; Young, Kelsey; Bleacher, Jacob E.; Garry, W. Brent; Rice, James W., Jr.

    2012-01-01

    Observation is the primary role of all field geologists, and geologic observations put into an evolving conceptual context will be the most important data stream that will be relayed to Earth during a planetary exploration mission. Sample collection is also an important planetary field activity, and its success is closely tied to the quality of contextual observations. To test protocols for doing effective planetary geologic field- work, the Desert RATS(Research and Technology Studies) project deployed two prototype rovers for two weeks of simulated exploratory traverses in the San Francisco volcanic field of northern Arizona. The authors of this paper represent the geologist crew members who participated in the 2010 field test.We document the procedures adopted for Desert RATS 2010 and report on our experiences regarding these protocols. Careful consideration must be made of various issues that impact the interplay between field geologic observations and sample collection, including time management; strategies relatedtoduplicationofsamplesandobservations;logisticalconstraintson the volume and mass of samples and the volume/transfer of data collected; and paradigms for evaluation of mission success. We find that the 2010 field protocols brought to light important aspects of each of these issues, and we recommend best practices and modifications to training and operational protocols to address them. Underlying our recommendations is the recognition that the capacity of the crew to flexibly execute their activities is paramount. Careful design of mission parameters, especially field geologic protocols, is critical for enabling the crews to successfully meet their science objectives.

  19. Improved Scanning Geometry to Collect 3D-Geometry Data in Flat Samples

    SciTech Connect

    Krueger, P.; Niese, S.; Zschech, E.; Gelb, J.; Feser, M.

    2011-09-09

    3D integration through silicon technology of integrated circuits challenges non-destructive testing methods. 3D x-ray methods are the techniques of choice to localize defects in interconnects. The development of high-power x-ray sources enabled the use of x-ray microscopy in laboratory tools. Those devices are able to resolve features down to 40 nm in an acceptable measurement time. However, the field of view is very limited to 16 {mu}m in high-resolution mode and to 65 {mu}m in large-field-of-view mode. To record tomography data, the size of the samples must not exceed the field of view to circumvent specific artifacts. Semiconductor samples usually do not fulfill the condition mentioned above since they have the shape of flat sheets. Therefore limited-angle tomography is typically used. The missing angles cause typical capping artifacts and poor signal-to-noise ratio. We present a modified scanning geometry that overcomes some of the artifacts and yields a better image quality. The geometry and potential applications are presented in comparison to the traditional limited-angle tomography.

  20. Tank 241-C-111 headspace gas and vapor characterization results for samples collected in August 1993 and September 1994

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.