Science.gov

Sample records for additional samples collected

  1. Sample collection, biobanking, and analysis.

    PubMed

    Ahsman, Maurice J; Tibboel, Dick; Mathot, Ron A A; de Wildt, Saskia N

    2011-01-01

    Pediatric pharmacokinetic studies require sampling of biofluids from neonates and children. Limitations on sampling frequency and sample volume complicate the design of these studies. In addition, strict guidelines, designed to guarantee patient safety, are in place. This chapter describes the practical implications of sample collection and their storage, with special focus on the selection of the appropriate type of biofluid and withdrawal technique. In addition, we describe appropriate measures for storage of these specimens, for example, in the context of biobanking, and the requirements on drug assay methods that they pose. Pharmacokinetic studies in children are possible, but they require careful selection of an appropriate sampling method, specimen volume, and assay method. The checklist provided could help prospective researchers with the design of an appropriate study protocol and infrastructure.

  2. Subsurface Samples: Collection and Processing

    SciTech Connect

    Long, Philip E.; Griffin, W. Timothy; Phelps, Tommy J.

    2002-12-01

    Microbiological data, interpretation, and conclusions from subsurface samples ultimately depend on the quality and representative character of the samples. Subsurface samples for environmental microbiology ideally contain only the microbial community and geochemical properties that are representative of the subsurface environment from which the sample was taken. To that end, sample contamination by exogenous microorganisms or chemical constituents must be eliminated or minimized, and sample analyses need to begin before changes in the microbial community or geochemical characteristics occur. This article presents sampling methods and sample processing techniques for collecting representative samples from a range of subsurface environments. Factors that should be considered when developing a subsurface sampling program are discussed, including potential benefits, costs, and limitations enabling researchers to evaluate the techniques that are presented and match them to their project requirements. Methods and protocols to address coring, sampling, processing and quality assessment issues are presented.

  3. Dynamic Method for Identifying Collected Sample Mass

    NASA Technical Reports Server (NTRS)

    Carson, John

    2008-01-01

    G-Sample is designed for sample collection missions to identify the presence and quantity of sample material gathered by spacecraft equipped with end effectors. The software method uses a maximum-likelihood estimator to identify the collected sample's mass based on onboard force-sensor measurements, thruster firings, and a dynamics model of the spacecraft. This makes sample mass identification a computation rather than a process requiring additional hardware. Simulation examples of G-Sample are provided for spacecraft model configurations with a sample collection device mounted on the end of an extended boom. In the absence of thrust knowledge errors, the results indicate that G-Sample can identify the amount of collected sample mass to within 10 grams (with 95-percent confidence) by using a force sensor with a noise and quantization floor of 50 micrometers. These results hold even in the presence of realistic parametric uncertainty in actual spacecraft inertia, center-of-mass offset, and first flexibility modes. Thrust profile knowledge is shown to be a dominant sensitivity for G-Sample, entering in a nearly one-to-one relationship with the final mass estimation error. This means thrust profiles should be well characterized with onboard accelerometers prior to sample collection. An overall sample-mass estimation error budget has been developed to approximate the effect of model uncertainty, sensor noise, data rate, and thrust profile error on the expected estimate of collected sample mass.

  4. Urine sample collection protocols for bioassay samples

    SciTech Connect

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject`s body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  5. Urine sample collection protocols for bioassay samples

    SciTech Connect

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject's body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  6. Optimising sample collection for placental research.

    PubMed

    Burton, G J; Sebire, N J; Myatt, L; Tannetta, D; Wang, Y-L; Sadovsky, Y; Staff, A C; Redman, C W

    2014-01-01

    Biobanks provide an important repository of samples for research purposes. However, for those samples to reflect the in vivo state, and for experimental reliability and reproducibility, careful attention to collection, processing and storage is essential. This is particularly true for the placenta, which is potentially subjected to stressful conditions during delivery, and sample collection may be delayed owing to routine postpartum inspection by clinical staff. In addition, standardisation of the collection procedure enables samples to be shared among research groups, allowing larger datasets to be established. Here, we provide an evidence-based and experts' review of the factors surrounding collection that may influence data obtained from the human placenta. We outline particular requirements for specific techniques, and propose a protocol for optimal sample collection. We recognise that the relevance of these factors, and of the sample types collected to a particular study will depend on the research questions being addressed. We therefore anticipate that researchers will select from the protocol to meet their needs and resources available. Wherever possible, we encourage researchers to extend their collection to include additional samples that can be shared on an international collaborative basis, with appropriate informed consent, to raise the quality, as well as quantity, of placental research.

  7. Biopolymers for sample collection, protection, and preservation.

    PubMed

    Sorokulova, Iryna; Olsen, Eric; Vodyanoy, Vitaly

    2015-07-01

    One of the principal challenges in the collection of biological samples from air, water, and soil matrices is that the target agents are not stable enough to be transferred from the collection point to the laboratory of choice without experiencing significant degradation and loss of viability. At present, there is no method to transport biological samples over considerable distances safely, efficiently, and cost-effectively without the use of ice or refrigeration. Current techniques of protection and preservation of biological materials have serious drawbacks. Many known techniques of preservation cause structural damages, so that biological materials lose their structural integrity and viability. We review applications of a novel bacterial preservation process, which is nontoxic and water soluble and allows for the storage of samples without refrigeration. The method is capable of protecting the biological sample from the effects of environment for extended periods of time and then allows for the easy release of these collected biological materials from the protective medium without structural or DNA damage. Strategies for sample collection, preservation, and shipment of bacterial, viral samples are described. The water-soluble polymer is used to immobilize the biological material by replacing the water molecules within the sample with molecules of the biopolymer. The cured polymer results in a solid protective film that is stable to many organic solvents, but quickly removed by the application of the water-based solution. The process of immobilization does not require the use of any additives, accelerators, or plastifiers and does not involve high temperature or radiation to promote polymerization.

  8. Fluid sample collection and storage device

    NASA Technical Reports Server (NTRS)

    Cohen, D.; Stone, S. E.

    1969-01-01

    Fluid sampling device collects a sample from a low-pressure fluid system and stores it for an indefinite period, with little risk of contamination of either the sample or the surrounding environment. The collector /a plastic bladder/ is separated from the sampler after a sample is collected.

  9. SAM Companion Documents and Sample Collection Procedures

    EPA Pesticide Factsheets

    SAM Companion Documents and Sample Collection Procedures provide information intended to complement the analytical methods listed in Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  10. Chapter A4. Collection of Water Samples

    USGS Publications Warehouse

    Wilde, Franceska D.

    1999-01-01

    The National Field Manual for the Collection of Water-Quality Data (National Field Manual) describes protocols and provides guidelines for U.S. Geological Survey (USGS) personnel who collect data that are used to assess the quality of the Nation's surface-water and ground-water resources. This chapter addresses preparations and appropriate methods for the collection of surface-water, groundwater, and associated quality-control samples. Among the topics covered are considerations and procedures to prevent sample contamination; establishing site files; instructions for collecting depth-integrated isokinetic and nonisokinetic samples at flowing- and still-water sites; and guidelines for collecting formation water from wells having various types of construction and hydraulic and aquifer characteristics.

  11. Sample collection system for gel electrophoresis

    SciTech Connect

    Olivares, Jose A.; Stark, Peter C.; Dunbar, John M.; Hill, Karen K.; Kuske, Cheryl R.; Roybal, Gustavo

    2004-09-21

    An automatic sample collection system for use with an electrophoretic slab gel system is presented. The collection system can be used with a slab gel have one or more lanes. A detector is used to detect particle bands on the slab gel within a detection zone. Such detectors may use a laser to excite fluorescently labeled particles. The fluorescent light emitted from the excited particles is transmitted to low-level light detection electronics. Upon the detection of a particle of interest within the detection zone, a syringe pump is activated, sending a stream of buffer solution across the lane of the slab gel. The buffer solution collects the sample of interest and carries it through a collection port into a sample collection vial.

  12. Asteroid Redirect Mission: EVA and Sample Collection

    NASA Technical Reports Server (NTRS)

    Abell, Paul; Stich, Steve

    2015-01-01

    Asteroid Redirect Mission (ARM) Overview (1) Notional Development Schedule, (2) ARV Crewed Mission Accommodations; Asteroid Redirect Crewed Mission (ARCM) Mission Summary; ARCM Accomplishments; Sample collection/curation plan (1) CAPTEM Requirements; SBAG Engagement Plan

  13. Pseudothrombocytopenia with multiple anticoagulant sample collection tubes

    PubMed Central

    Kovacs, Ferenc; Varga, Marina; Pataki, Zsolt; Rigo, Erzsebet

    2016-01-01

    The knowledge of pseudothrombocytopenia (PTCP) is important for the accuracy of a clinical assessment and for avoiding unnecessary treatment. An elderly patient was hospitalized with left lung pneumonia. Severe thrombocytopenia [platelet (PLT) number: 18 × 109/L] without any clinical bleeding was found in ethylenediaminetetraacetic acid blood collection tube. PLT measurement was repeated in various anticoagulant [sodium citrate, lithium heparin, disodium oxalate, hirudin, and magnesium sulfate (Mg-sulfate)] sample collection tubes and all of them showed thrombocytopenia except with Mg-sulfate. To the best of our knowledge, PTCP with five anticoagulant sample collection tubes has not been reported earlier. PMID:28180009

  14. Final Report BW Sample Collection& Preparation Device

    SciTech Connect

    Koopman, R P; Belgrader, P; Meyer, G; Benett, W J; Richards, J B; Hadley, D R; Stratton, P L; Milanovich, F P

    2002-01-31

    The objective of this project was to develop the technique needed to prepare a field collected sample for laboratory analysis and build a portable integrated biological detection instrument with new miniaturized and automated sample purification capabilities. The device will prepare bacterial spores, bacterial vegetative cells, and viral particles for PCR amplification.

  15. 75 FR 43989 - Agency Information Collection Activities; Proposed Collection; Comment Request; Sample Collection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-27

    ... Collection; Comment Request; Sample Collection Plan for Dogs Treated With SLENTROL AGENCY: Food and Drug... response to the notice. This notice solicits comments on the sample collection plan for dogs treated with... appropriate, and other forms of information technology. Sample Collection Plan for Dogs Treated With...

  16. Automated Sample collection and Analysis unit

    SciTech Connect

    Latner, Norman; Sanderson, Colin G.; Negro, Vincent C.

    1999-03-31

    Autoramp is an atmospheric radionuclide collection and analysis unit designed for unattended operation. A large volume of air passes through one of 31 filter cartridges which is then moved from a sampling chamber and past a bar code reader, to a shielded enclosure. The collected dust-borne radionuclides are counted with a high resolution germanium gamma-ray detector. An analysis is made and the results are transmitted to a central station that can also remotely control the unit.

  17. 7 CFR 27.25 - Additional samples of cotton; drawing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Additional samples of cotton; drawing. 27.25 Section... CONTAINER REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.25 Additional samples of cotton; drawing. In addition to the samples hereinbefore...

  18. 7 CFR 27.25 - Additional samples of cotton; drawing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Additional samples of cotton; drawing. 27.25 Section... CONTAINER REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.25 Additional samples of cotton; drawing. In addition to the samples hereinbefore...

  19. 7 CFR 27.25 - Additional samples of cotton; drawing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Additional samples of cotton; drawing. 27.25 Section... CONTAINER REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.25 Additional samples of cotton; drawing. In addition to the samples hereinbefore...

  20. 7 CFR 27.25 - Additional samples of cotton; drawing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Additional samples of cotton; drawing. 27.25 Section... CONTAINER REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.25 Additional samples of cotton; drawing. In addition to the samples hereinbefore...

  1. 7 CFR 27.25 - Additional samples of cotton; drawing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Additional samples of cotton; drawing. 27.25 Section... CONTAINER REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.25 Additional samples of cotton; drawing. In addition to the samples hereinbefore...

  2. Avian influenza virus sample types, collection, and handling.

    PubMed

    Killian, Mary Lea

    2014-01-01

    Successful detection of avian influenza (AI) virus, viral antigen, nucleic acid, or antibody is dependent upon the collection of the appropriate sample type, the quality of the sample, and the proper storage and handling of the sample. The diagnostic tests to be performed should be considered prior to sample collection. Sera are acceptable samples for ELISA or agar gel precipitin tests, but not for real-time RT-PCR. Likewise, swabs and/or tissues are acceptable for real-time RT-PCR and virus isolation. The sample type will also depend on the type of birds that are being tested; although it is optimal to collect both oropharyngeal and cloacal swabs, oropharyngeal swabs should be collected from gallinaceous poultry and cloacal swabs should be collected from waterfowl. In addition to collecting the appropriate sample for the tests to be performed, selecting the right materials for sample collection (i.e., type of swab) is very important. This chapter outlines the collection of different specimen types and procedures for proper specimen handling.

  3. 5 CFR 179.218 - Additional administrative collection action.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Additional administrative collection action. 179.218 Section 179.218 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS CLAIMS COLLECTION STANDARDS Salary Offset § 179.218 Additional administrative collection...

  4. Automated collection and processing of environmental samples

    DOEpatents

    Troyer, Gary L.; McNeece, Susan G.; Brayton, Darryl D.; Panesar, Amardip K.

    1997-01-01

    For monitoring an environmental parameter such as the level of nuclear radiation, at distributed sites, bar coded sample collectors are deployed and their codes are read using a portable data entry unit that also records the time of deployment. The time and collector identity are cross referenced in memory in the portable unit. Similarly, when later recovering the collector for testing, the code is again read and the time of collection is stored as indexed to the sample collector, or to a further bar code, for example as provided on a container for the sample. The identity of the operator can also be encoded and stored. After deploying and/or recovering the sample collectors, the data is transmitted to a base processor. The samples are tested, preferably using a test unit coupled to the base processor, and again the time is recorded. The base processor computes the level of radiation at the site during exposure of the sample collector, using the detected radiation level of the sample, the delay between recovery and testing, the duration of exposure and the half life of the isotopes collected. In one embodiment, an identity code and a site code are optically read by an image grabber coupled to the portable data entry unit.

  5. Astronaut John Young photographed collecting lunar samples

    NASA Technical Reports Server (NTRS)

    1972-01-01

    Astronaut John W. Young, commander of the Apollo 16 lunar landing mission, is photographed collecting lunar samples near North Ray crater during the third Apollo 16 extravehicular activity (EVA-3) at the Descartes landing site. This picture was taken by Astronaut Charles M. Duke Jr., lunar module pilot. Young is using the lunar surface rake and a set of tongs. The Lunar Roving Vehicle is parked in the field of large boulders in the background.

  6. Matrix isolation apparatus with extended sample collection capability

    DOEpatents

    Reedy, Gerald T.

    1987-01-01

    A gas-sample collection device provides for the matrix isolation of increased amounts of a sample material for spectrographic analysis from a gas chromatographic separation. The device includes an evacuated sample collection chamber containing a disc-like specular carousel having a generally circular lateral surface upon which the sample is deposited in an inert gas matrix for infrared (IR) spectral analysis. The evacuated sample chamber is mounted in a fixed manner and is coupled to and supports a rotating cryostatic coupler which, in turn, supports the specular carousel within the collection chamber. A rotational drive system connected to the cryostatic coupler provides for its rotational displacement as well as that of the sample collecting carousel. In addition, rotation of the cryostatic coupler effects vertical displacement of the carousel to permit the collection of an extended sample band in a helical configuration on the entire lateral surface of the carousel. The various components of the carousel's angular/linear displacement drive system are located exterior to the cryostatic coupler for easy access and improved operation. The cryostatic coupler includes a 360.degree. rotary union assembly for permitting the delivery of a high pressure working fluid to the cryostatic coupler in a continuous flow manner for maintaining the specular carousel at a low temperature, e.g., 10.degree.-20.degree. K., for improved uninterrupted gas sample collection and analysis.

  7. 45 CFR 33.16 - Additional administrative collection action.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Additional administrative collection action. 33.16 Section 33.16 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION SALARY OFFSET § 33.16 Additional administrative collection action. Nothing contained in this part is intended...

  8. Urine sampling and collection system optimization and testing

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Geating, J. A.; Koesterer, M. G.

    1975-01-01

    A Urine Sampling and Collection System (USCS) engineering model was developed to provide for the automatic collection, volume sensing and sampling of urine from each micturition. The purpose of the engineering model was to demonstrate verification of the system concept. The objective of the optimization and testing program was to update the engineering model, to provide additional performance features and to conduct system testing to determine operational problems. Optimization tasks were defined as modifications to minimize system fluid residual and addition of thermoelectric cooling.

  9. Rapid Remote Sample Collection Mechanism for Near-Earth Asteroid Sample Return

    NASA Astrophysics Data System (ADS)

    Nygren, W. D.

    2000-01-01

    The Rapid Remote Sample Collection (RRSC) system is an innovative approach to the collection of regolith samples from the surface of comets or asteroids without landing the main body of the spacecraft on the surface. The RRSC system rapidly captures and retrieves a sample while the spacecraft momentarily hovers or slowly descends and-or drifts approximately 5 m above the body's surface. In this way the surface is not disturbed by landing thrusters, and the mass, volume, and complexity associated with landing and landing legs is eliminated. The sample collecting mechanism consists of an auger driven by the energy stored in a flywheel and a torroidal sample collection chamber wrapped around and rotating with the auger. The sample collector is deployed and retrieved by a Storable Tubular Extendable Member or STEM manufactured by TRW Astro Aerospace. This mechanism is similar to a motorized carpenters tape measure. Additional information is contained in the original extended abstract.

  10. Importance of sampling frequency when collecting diatoms

    PubMed Central

    Wu, Naicheng; Faber, Claas; Sun, Xiuming; Qu, Yueming; Wang, Chao; Ivetic, Snjezana; Riis, Tenna; Ulrich, Uta; Fohrer, Nicola

    2016-01-01

    There has been increasing interest in diatom-based bio-assessment but we still lack a comprehensive understanding of how to capture diatoms’ temporal dynamics with an appropriate sampling frequency (ASF). To cover this research gap, we collected and analyzed daily riverine diatom samples over a 1-year period (25 April 2013–30 April 2014) at the outlet of a German lowland river. The samples were classified into five clusters (1–5) by a Kohonen Self-Organizing Map (SOM) method based on similarity between species compositions over time. ASFs were determined to be 25 days at Cluster 2 (June-July 2013) and 13 days at Cluster 5 (February-April 2014), whereas no specific ASFs were found at Cluster 1 (April-May 2013), 3 (August-November 2013) (>30 days) and Cluster 4 (December 2013 - January 2014) (<1 day). ASFs showed dramatic seasonality and were negatively related to hydrological wetness conditions, suggesting that sampling interval should be reduced with increasing catchment wetness. A key implication of our findings for freshwater management is that long-term bio-monitoring protocols should be developed with the knowledge of tracking algal temporal dynamics with an appropriate sampling frequency. PMID:27841310

  11. Importance of sampling frequency when collecting diatoms

    NASA Astrophysics Data System (ADS)

    Wu, Naicheng; Faber, Claas; Sun, Xiuming; Qu, Yueming; Wang, Chao; Ivetic, Snjezana; Riis, Tenna; Ulrich, Uta; Fohrer, Nicola

    2016-11-01

    There has been increasing interest in diatom-based bio-assessment but we still lack a comprehensive understanding of how to capture diatoms’ temporal dynamics with an appropriate sampling frequency (ASF). To cover this research gap, we collected and analyzed daily riverine diatom samples over a 1-year period (25 April 2013–30 April 2014) at the outlet of a German lowland river. The samples were classified into five clusters (1–5) by a Kohonen Self-Organizing Map (SOM) method based on similarity between species compositions over time. ASFs were determined to be 25 days at Cluster 2 (June-July 2013) and 13 days at Cluster 5 (February-April 2014), whereas no specific ASFs were found at Cluster 1 (April-May 2013), 3 (August-November 2013) (>30 days) and Cluster 4 (December 2013 - January 2014) (<1 day). ASFs showed dramatic seasonality and were negatively related to hydrological wetness conditions, suggesting that sampling interval should be reduced with increasing catchment wetness. A key implication of our findings for freshwater management is that long-term bio-monitoring protocols should be developed with the knowledge of tracking algal temporal dynamics with an appropriate sampling frequency.

  12. 21 CFR 71.4 - Samples; additional information.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Samples; additional information. 71.4 Section 71.4 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL COLOR... samples of the color additive, articles used as components thereof, or of the food, drug, or cosmetic...

  13. 21 CFR 71.4 - Samples; additional information.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Samples; additional information. 71.4 Section 71.4 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL COLOR... samples of the color additive, articles used as components thereof, or of the food, drug, or cosmetic...

  14. Designing an enhanced groundwater sample collection system

    SciTech Connect

    Schalla, R.

    1994-10-01

    As part of an ongoing technical support mission to achieve excellence and efficiency in environmental restoration activities at the Laboratory for Energy and Health-Related Research (LEHR), Pacific Northwest Laboratory (PNL) provided guidance on the design and construction of monitoring wells and identified the most suitable type of groundwater sampling pump and accessories for monitoring wells. The goal was to utilize a monitoring well design that would allow for hydrologic testing and reduce turbidity to minimize the impact of sampling. The sampling results of the newly designed monitoring wells were clearly superior to those of the previously installed monitoring wells. The new wells exhibited reduced turbidity, in addition to improved access for instrumentation and hydrologic testing. The variable frequency submersible pump was selected as the best choice for obtaining groundwater samples. The literature references are listed at the end of this report. Despite some initial difficulties, the actual performance of the variable frequency, submersible pump and its accessories was effective in reducing sampling time and labor costs, and its ease of use was preferred over the previously used bladder pumps. The surface seals system, called the Dedicator, proved to be useful accessory to prevent surface contamination while providing easy access for water-level measurements and for connecting the pump. Cost savings resulted from the use of the pre-production pumps (beta units) donated by the manufacturer for the demonstration. However, larger savings resulted from shortened field time due to the ease in using the submersible pumps and the surface seal access system. Proper deployment of the monitoring wells also resulted in cost savings and ensured representative samples.

  15. Curating NASA's Past, Present, and Future Astromaterial Sample Collections

    NASA Technical Reports Server (NTRS)

    Zeigler, R. A.; Allton, J. H.; Evans, C. A.; Fries, M. D.; McCubbin, F. M.; Nakamura-Messenger, K.; Righter, K.; Zolensky, M.; Stansbery, E. K.

    2016-01-01

    The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC curation) is responsible for curating all of NASA's extraterrestrial samples. JSC presently curates 9 different astromaterials collections in seven different clean-room suites: (1) Apollo Samples (ISO (International Standards Organization) class 6 + 7); (2) Antarctic Meteorites (ISO 6 + 7); (3) Cosmic Dust Particles (ISO 5); (4) Microparticle Impact Collection (ISO 7; formerly called Space-Exposed Hardware); (5) Genesis Solar Wind Atoms (ISO 4); (6) Stardust Comet Particles (ISO 5); (7) Stardust Interstellar Particles (ISO 5); (8) Hayabusa Asteroid Particles (ISO 5); (9) OSIRIS-REx Spacecraft Coupons and Witness Plates (ISO 7). Additional cleanrooms are currently being planned to house samples from two new collections, Hayabusa 2 (2021) and OSIRIS-REx (2023). In addition to the labs that house the samples, we maintain a wide variety of infra-structure facilities required to support the clean rooms: HEPA-filtered air-handling systems, ultrapure dry gaseous nitrogen systems, an ultrapure water system, and cleaning facilities to provide clean tools and equipment for the labs. We also have sample preparation facilities for making thin sections, microtome sections, and even focused ion-beam sections. We routinely monitor the cleanliness of our clean rooms and infrastructure systems, including measurements of inorganic or organic contamination, weekly airborne particle counts, compositional and isotopic monitoring of liquid N2 deliveries, and daily UPW system monitoring. In addition to the physical maintenance of the samples, we track within our databases the current and ever changing characteristics (weight, location, etc.) of more than 250,000 individually numbered samples across our various collections, as well as more than 100,000 images, and countless "analog" records that record the sample processing records of each individual sample. JSC Curation is co-located with JSC

  16. Evaluation of Vacuum-based Sampling Devices for Collection ...

    EPA Pesticide Factsheets

    Report The existing surface sampling strategy for a biological incident involving B. anthracis spores requires the use of various methods depending on the surface type. This project comparatively evaluated the vacuum sock and two additional vacuum-based collection devices (37 mm filter cassette and 3M™ Trace Evidence Filter) for their sampling efficacy. The 37 mm filter cassette was evaluated with mixed cellulose ester (MCE) filters or polytetrafluoroethylene (PTFE) filters installed, each was considered a unique device. These data were generated so appropriate sampling devices could be selected following a B. anthracis incident. Bacillus atrophaeus was used a surrogate.

  17. 28 CFR 28.12 - Collection of DNA samples.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection, Analysis, and Indexing § 28.12 Collection of DNA samples. (a) The Bureau of Prisons shall collect a...

  18. 28 CFR 28.12 - Collection of DNA samples.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 1 2011-07-01 2011-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection, Analysis, and Indexing § 28.12 Collection of DNA samples. (a) The Bureau of Prisons shall collect a...

  19. 28 CFR 28.12 - Collection of DNA samples.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 1 2014-07-01 2014-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection, Analysis, and Indexing § 28.12 Collection of DNA samples. (a) The Bureau of Prisons shall collect a...

  20. 28 CFR 28.12 - Collection of DNA samples.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 1 2012-07-01 2012-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection, Analysis, and Indexing § 28.12 Collection of DNA samples. (a) The Bureau of Prisons shall collect a...

  1. 28 CFR 28.12 - Collection of DNA samples.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 1 2013-07-01 2013-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection, Analysis, and Indexing § 28.12 Collection of DNA samples. (a) The Bureau of Prisons shall collect a...

  2. Comparison of aquatic macroinvertebrate samples collected using different field methods

    USGS Publications Warehouse

    Lenz, Bernard N.; Miller, Michael A.

    1996-01-01

    Government agencies, academic institutions, and volunteer monitoring groups in the State of Wisconsin collect aquatic macroinvertebrate data to assess water quality. Sampling methods differ among agencies, reflecting the differences in the sampling objectives of each agency. Lack of infor- mation about data comparability impedes data shar- ing among agencies, which can result in duplicated sampling efforts or the underutilization of avail- able information. To address these concerns, com- parisons were made of macroinvertebrate samples collected from wadeable streams in Wisconsin by personnel from the U.S. Geological Survey- National Water Quality Assessment Program (USGS-NAWQA), the Wisconsin Department of Natural Resources (WDNR), the U.S. Department of Agriculture-Forest Service (USDA-FS), and volunteers from the Water Action Volunteer-Water Quality Monitoring Program (WAV). This project was part of the Intergovernmental Task Force on Monitoring Water Quality (ITFM) Wisconsin Water Resources Coordination Project. The numbers, types, and environmental tolerances of the organ- isms collected were analyzed to determine if the four different field methods that were used by the different agencies and volunteer groups provide comparable results. Additionally, this study com- pared the results of samples taken from different locations and habitats within the same streams.

  3. 75 FR 77645 - Agency Information Collection Activities; Proposed Collection; Comment Request; Color Additive...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-13

    ... Collection; Comment Request; Color Additive Certification Requests and Recordkeeping AGENCY: Food and Drug... certification of color additives manufactured for use in foods, drugs, cosmetics or medical devices in the... of information technology. Color Additive Certification Requests and Recordkeeping--21 CFR Part...

  4. Total airborne mold particle sampling: evaluation of sample collection, preparation and counting procedures, and collection devices.

    PubMed

    Godish, Diana; Godish, Thad

    2008-02-01

    This study was conducted to evaluate (i) procedures used to collect, prepare, and count total airborne mold spore/particle concentrations, and (ii) the relative field performance of three commercially available total airborne mold spore/particle sampling devices. Differences between factory and laboratory airflow calibration values of axial fan-driven sampling instruments (used in the study) indicated a need for laboratory calibration using a mass flow meter to ensure that sample results were accurately calculated. An aniline blue-amended Calberla's solution adjusted to a pH of 4.2-4.4 provided good sample mounting/counting results using Dow Corning high vacuum grease, Dow Corning 280A adhesive, and Dow Corning 316 silicone release spray for samples collected using mini-Burkard and Allergenco samplers. Count variability among analysts was most pronounced in 5% counts of relatively low mold particle deposition density samples and trended downward with increased count percentage and particle deposition density. No significant differences were observed among means of 5, 10, and 20% counts and among analysts; a significant interaction effect was observed between analysts' counts and particle deposition densities. Significantly higher mini-Burkard and Air-O-Cell total mold spore/particle counts for 600x vs. 400x (1.9 and 2.3 x higher, respectively), 1000x vs. 600x (1.9 and 2.2 x higher, respectively) and 1000x vs. 400x (3.6 and 4.6 x higher, respectively) comparisons indicated that 1000x magnification counts best quantified total airborne mold spore/particles using light microscopy, and that lower magnification counts may result in unacceptable underreporting of airborne mold spore/particle concentrations. Modest but significantly higher (1.2x) total mold spore concentrations were observed with Allergenco vs. mini-Burkard samples collected in co-located, concurrently operated sampler studies; moderate but significantly higher mini-Burkard count values (1.4x) were

  5. Analysis of the research sample collections of Uppsala biobank.

    PubMed

    Engelmark, Malin T; Beskow, Anna H

    2014-10-01

    Uppsala Biobank is the joint and only biobank organization of the two principals, Uppsala University and Uppsala University Hospital. Biobanks are required to have updated registries on sample collection composition and management in order to fulfill legal regulations. We report here the results from the first comprehensive and overall analysis of the 131 research sample collections organized in the biobank. The results show that the median of the number of samples in the collections was 700 and that the number of samples varied from less than 500 to over one million. Blood samples, such as whole blood, serum, and plasma, were included in the vast majority, 84.0%, of the research sample collections. Also, as much as 95.5% of the newly collected samples within healthcare included blood samples, which further supports the concept that blood samples have fundamental importance for medical research. Tissue samples were also commonly used and occurred in 39.7% of the research sample collections, often combined with other types of samples. In total, 96.9% of the 131 sample collections included samples collected for healthcare, showing the importance of healthcare as a research infrastructure. Of the collections that had accessed existing samples from healthcare, as much as 96.3% included tissue samples from the Department of Pathology, which shows the importance of pathology samples as a resource for medical research. Analysis of different research areas shows that the most common of known public health diseases are covered. Collections that had generated the most publications, up to over 300, contained a large number of samples collected systematically and repeatedly over many years. More knowledge about existing biobank materials, together with public registries on sample collections, will support research collaborations, improve transparency, and bring us closer to the goals of biobanks, which is to save and prolong human lives and improve health and quality of life.

  6. Sample Collection for Investigation of Mars (SCIM): An Early Mars Sample Return Mission Through the Mars Scout Program

    NASA Technical Reports Server (NTRS)

    Leshin, L. A.; Yen, A.; Bomba, J.; Clark, B.; Epp, C.; Forney, L.; Gamber, T.; Graves, C.; Hupp, J.; Jones, S.

    2002-01-01

    The Sample Collection for Investigation of Mars (SCIM) mission is designed to: (1) make a 40 km pass through the Martian atmosphere; (2) collect dust and atmospheric gas; and (3) return the samples to Earth for analysis. Additional information is contained in the original extended abstract.

  7. Issues in Collecting and Transcribing Speech Samples.

    ERIC Educational Resources Information Center

    Louko, Linda J.; Edwards, Mary Louise

    2001-01-01

    This article identifies issues in phonetic transcription of speech samples for speech language pathologists. Important terms and concepts from articulatory/clinical phonetics are reviewed and guidelines are provided for streamlining the process of whole-word live transcriptions and for refining transcriptions by incorporating features from…

  8. Biopolymers for Sample Collection, Protection, and Preservation

    DTIC Science & Technology

    2015-05-19

    biological materials lose their structural integrity and viability. We review applications of a novel bacterial preservation process , which is nontoxic...based solution. The process of immobilization does not require the use of any additives, accelerators, or plastifiers and does not involve high...so that biological materials lose their structural integrity and viability. We review applications of a novel bacterial preservation process , which

  9. 40 CFR 761.286 - Sample size and procedure for collecting a sample.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS Sampling To Verify Completion of Self-Implementing Cleanup and...) § 761.286 Sample size and procedure for collecting a sample. At each selected sampling location for...

  10. Snow White Trench Prepared for Sample Collection

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The informally named 'Snow White' trench is the source for the next sample to be acquired by NASA's Phoenix Mars Lander for analysis by the wet chemistry lab.

    The Surface Stereo Imager on Phoenix took this shadow-enhanced image of the trench, on the eastern end of Phoenix's work area, on Sol 103, or the 103rd day of the mission, Sept. 8, 2008. The trench is about 23 centimeters (9 inches) wide.

    The wet chemistry lab is part of Phoenix's Microscopy, Electrochemistry and Conductivity suite of instruments.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  11. USEPA/USGS Sample Collection Protocol for Bacterial ...

    EPA Pesticide Factsheets

    Report/SOP This Sample Collection Procedure (SCP) describes the activities and considerations for the collection of bacterial pathogens from representative surface soil samples (0-5 cm). This sampling depth can be reached without the use of a drill rig, direct-push technology, or other mechanized equipment. Analizing soil samples for biothreat agents may, for instance, define the extent of contamination or determine whether the concentrations of contaminants present a risk to public health, welfare, or the environment.

  12. The development of a Martian atmospheric Sample collection canister

    NASA Astrophysics Data System (ADS)

    Kulczycki, E.; Galey, C.; Kennedy, B.; Budney, C.; Bame, D.; Van Schilfgaarde, R.; Aisen, N.; Townsend, J.; Younse, P.; Piacentine, J.

    The collection of an atmospheric sample from Mars would provide significant insight to the understanding of the elemental composition and sub-surface out-gassing rates of noble gases. A team of engineers at the Jet Propulsion Laboratory (JPL), California Institute of Technology have developed an atmospheric sample collection canister for Martian application. The engineering strategy has two basic elements: first, to collect two separately sealed 50 cubic centimeter unpressurized atmospheric samples with minimal sensing and actuation in a self contained pressure vessel; and second, to package this atmospheric sample canister in such a way that it can be easily integrated into the orbiting sample capsule for collection and return to Earth. Sample collection and integrity are demonstrated by emulating the atmospheric collection portion of the Mars Sample Return mission on a compressed timeline. The test results achieved by varying the pressure inside of a thermal vacuum chamber while opening and closing the valve on the sample canister at Mars ambient pressure. A commercial off-the-shelf medical grade micro-valve is utilized in the first iteration of this design to enable rapid testing of the system. The valve has been independently leak tested at JPL to quantify and separate the leak rates associated with the canister. The results are factored in to an overall system design that quantifies mass, power, and sensing requirements for a Martian atmospheric Sample Collection (MASC) canister as outlined in the Mars Sample Return mission profile. Qualitative results include the selection of materials to minimize sample contamination, preliminary science requirements, priorities in sample composition, flight valve selection criteria, a storyboard from sample collection to loading in the orbiting sample capsule, and contributions to maintaining “ Earth” clean exterior surfaces on the orbiting sample capsule.

  13. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide...

  14. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide...

  15. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide...

  16. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide...

  17. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide...

  18. Scientific guidelines for preservation of samples collected from Mars

    NASA Technical Reports Server (NTRS)

    Gooding, James L. (Editor)

    1990-01-01

    The maximum scientific value of Martian geologic and atmospheric samples is retained when the samples are preserved in the conditions that applied prior to their collection. Any sample degradation equates to loss of information. Based on detailed review of pertinent scientific literature, and advice from experts in planetary sample analysis, number values are recommended for key parameters in the environmental control of collected samples with respect to material contamination, temperature, head-space gas pressure, ionizing radiation, magnetic fields, and acceleration/shock. Parametric values recommended for the most sensitive geologic samples should also be adequate to preserve any biogenic compounds or exobiological relics.

  19. Additional sampling directions improve detection range of wireless radiofrequency probes

    PubMed Central

    Mada, Marius; Carpenter, T. Adrian; Sawiak, Stephen J.; Williams, Guy B.

    2015-01-01

    Purpose While MRI is enhancing our knowledge about the structure and function of the human brain, subject motion remains a problem in many clinical applications. Recently, the use of wireless radiofrequency markers with three one‐dimensional (1D) navigators for prospective correction was demonstrated. This method is restricted in the range of motion that can be corrected, however, because of limited information in the 1D readouts. Methods Here, the limitation of techniques for disambiguating marker locations was investigated. It was shown that including more sampling directions extends the tracking range for head rotations. The efficiency of trading readout resolution for speed was explored. Results Tracking of head rotations was demonstrated from −19.2 to 34.4°, −2.7 to 10.0°, and −60.9 to 70.9° in the x‐, y‐, and z‐directions, respectively. In the presence of excessive head motion, the deviation of marker estimates from SPM8 was reduced by 17.1% over existing three‐projection methods. This was achieved by using an additional seven directions, extending the time needed for readouts by a factor of 3.3. Much of this increase may be circumvented by reducing resolution, without compromising accuracy. Conclusion Including additional sampling directions extends the range in which markers can be used, for patients who move a lot. Magn Reson Med 76:913–918, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. PMID:26418189

  20. Miniature Blimps for Surveillance and Collection of Samples

    NASA Technical Reports Server (NTRS)

    Jones, Jack

    2004-01-01

    Miniature blimps are under development as robots for use in exploring the thick, cold, nitrogen atmosphere of Saturn's moon, Titan. Similar blimps can also be used for surveillance and collection of biochemical samples in buildings, caves, subways, and other, similar structures on Earth. The widely perceived need for means to thwart attacks on buildings and to mitigate the effects of such attacks has prompted consideration of the use of robots. Relative to rover-type (wheeled) robots that have been considered for such uses, miniature blimps offer the advantage of ability to move through the air in any direction and, hence, to perform tasks that are difficult or impossible for wheeled robots, including climbing stairs and looking through windows. In addition, miniature blimps are expected to have greater range and to cost less, relative to wheeled robots.

  1. CHARACTERIZATION OF CORE SAMPLE COLLECTED FROM THE SALTSTONE DISPOSAL FACILITY

    SciTech Connect

    Cozzi, A.; Duncan, A.

    2010-01-28

    During the month of September 2008, grout core samples were collected from the Saltstone Disposal Facility, Vault 4, cell E. This grout was placed during processing campaigns in December 2007 from Deliquification, Dissolution and Adjustment Batch 2 salt solution. The 4QCY07 Waste Acceptance Criteria sample collected on 11/16/07 represents the salt solution in the core samples. Core samples were retrieved to initiate the historical database of properties of emplaced Saltstone and to demonstrate the correlation between field collected and laboratory prepared samples. Three samples were collected from three different locations. Samples were collected using a two-inch diameter concrete coring bit. In April 2009, the core samples were removed from the evacuated sample container, inspected, transferred to PVC containers, and backfilled with nitrogen. Samples furthest from the wall were the most intact cylindrically shaped cored samples. The shade of the core samples darkened as the depth of coring increased. Based on the visual inspection, sample 3-3 was selected for all subsequent analysis. The density and porosity of the Vault 4 core sample, 1.90 g/cm{sup 3} and 59.90% respectively, were comparable to values achieved for laboratory prepared samples. X-ray diffraction analysis identified phases consistent with the expectations for hydrated Saltstone. Microscopic analysis revealed morphology features characteristic of cementitious materials with fly ash and calcium silicate hydrate gel. When taken together, the results of the density, porosity, x-ray diffraction analysis and microscopic analysis support the conclusion that the Vault 4, Cell E core sample is representative of the expected waste form.

  2. Collection, storage, and electrophoretic analysis of nanoliter microdialysis samples collected from awake animals in vivo

    PubMed Central

    Wang, Meng; Hershey, Neil D.; Mabrouk, Omar S.

    2011-01-01

    Microdialysis sampling is an important tool for chemical monitoring in living systems. Temporal resolution is an important figure of merit that is determined by sampling frequency, assay sensitivity, and dispersion of chemical zones during transport from sampling device to fraction collector or analytical system. Temporal resolution has recently been improved by segmenting flow into plugs, so that nanoliter fractions are collected at intervals of 0.1–2 s, thus eliminating temporal distortion associated with dispersion in continuous flow. Such systems, however, have yet to be used with behaving subjects. Furthermore, long-term storage of nanoliter samples created by segmented flow has not been reported. In this work, we have addressed these challenges. A microdialysis probe was integrated to a plug generator that could be stably mounted onto behaving animals. Long-term storage of dialysate plugs was achieved by collecting plugs into high-purity perfluoroalkoxy tubes, placing the tube into hexane and then freezing at −80°C. Slow warming with even temperatures prevented plug coalescence during sample thawing. As a demonstration of the system, plugs were collected from the striatum of behaving rats using a 0.5-mm-long microdialysis probe. Resulting plugs were analyzed 1–4 days later by chip-based electrophoresis. To improve throughput of plug analysis over previous work, the speed of electrophoretic separation was increased by using forced air cooling and 1-butyl-2,3-dimethylimidazolium tetrafluoroborate as a separation buffer additive, allowing resolution of six neuroactive amino acids in 30 s. Concentration changes induced by K+ microinjections were monitored with 10 s temporal resolution. The improvements reported in this work make it possible to apply segmented flow microdialysis to the study of behaving animals and enable experiments where the analytical system cannot be placed close to the animal. PMID:21465093

  3. Study of Cloud Water Samples Collected over Northern Poland.

    PubMed

    Polkowska, Ż; Błaś, M; Lech, D; Namieśnik, J

    2014-01-01

    The paper gives the results of the first studies on the chemistry of cloud water collected during 3 mo (Aug.-Oct. 2010) in the free atmosphere over the area to the south of the Tri-City (Gdansk-Sopot-Gdynia) conurbation on the Gulf of Gdansk, Poland. Taken from cumulus, stratus, and stratocumulus clouds by means of an aircraft-mounted collector, the water samples were analyzed for the following contaminants: anions (chlorides, fluorides, nitrates, sulfates, and phosphates), cations (lithium, sodium, potassium, ammonium, calcium, and magnesium), and trace metals. In addition, pH values were measured, and the type and composition of suspended particulate matter was determined. We discuss the relationship between the concentration of inorganic ions and the type of cloud from which water was sampled. The chemistry is also likely related to the circulation pattern and inflow of clean air masses from the Baltic Sea. Moreover, a relationship was found between the composition of the samples examined and the location of pollutant emission sources.

  4. A perception and manipulation system for collecting rock samples

    NASA Technical Reports Server (NTRS)

    Choi, T.; Delingette, H.; Deluise, M.; Hsin, Y.; Hebert, M.; Ikeuchi, Katsushi

    1991-01-01

    An important part of a planetary exploration mission is to collect and analyze surface samples. As part of the Carnegie Mellon University Ambler Project, researchers are investigating techniques for collecting samples using a robot arm and a range sensor. The aim of this work is to make the sample collection operation fully autonomous. Described here are the components of the experimental system, including a perception module that extracts objects of interest from range images and produces models of their shapes, and a manipulation module that enables the system to pick up the objects identified by the perception module. The system was tested on a small testbed using natural terrain.

  5. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure for young children wearing diapers, a method for collecting urine samples for analysis of pesticide metabolites is needed. To find a practical method, two possibilities were investigated: (1) analysis of expressed urine from cotton diaper inserts ...

  6. SAMPLE COLLECTION AND HANDLING FOR MICROBIOLOGICAL EXAMINATION OF BIOSOLIDS

    EPA Science Inventory

    The objective of this presentation is to discuss sample collection and handling methods currently in use for detection and enumeration of microorganisms in biosolids and municipal wastewater sludges. Untreated sludges and biosolids are rarely homogeneous and present a challenge ...

  7. Hydrodynamic effects in buccal cell DNA sample collection

    NASA Astrophysics Data System (ADS)

    Aidun, C. K.; Sozer, A. C.

    2003-11-01

    Many different methods can be used for collection of biological samples from individuals for DNA profiling purposes. However, blood and buccal cells are the two most popular sources of DNA. In situations where large numbers of samples have to be collected, buccal cell collection methods are the preferred choice because of minimized health risks and ease of collection, transportation, and storage. The normal practice in buccal cell collection is to rub a cotton swab or a piece of paper through the inner check of the subject in order to release the cells and to attach and collect the cells on the cotton or paper fibers. The problem with the current forms of sample collection and storage is that in some cases up to 20% of the samples collected do not result in a DNA profile of adequate quality to be reported by the laboratory without repeated testing. In this study, we consider the mechanics of a small sheet of paper being rubbed on the surface of the inner check. The process is not too different from coating a paper substrate with highly deformable material. The shear field developed between the paper and the fluid adjacent to the cells are estimated based on the available data. The action of the cell release and the cell adherence to the surface will be outlined.

  8. Collection, chemical analysis, and evaluation of coal samples in 1975

    USGS Publications Warehouse

    Swanson, Vernon Emanuel; Medlin, J.H.; Hatch, J.R.; Coleman, S.L.; Wood, G.H.; Woodruff, S.D.; Hildebrand, R.T.

    1976-01-01

    During 1975, the U.S. Geological Survey, in cooperation with other Federal and State agencies, university groups, and private companies, continued its program to augment and refine information on the composition of coal in the United States. This report includes all analytical data on 799 channel samples of coal beds from major operating mines and core holes in 28 States, collected mainly by State Geological Surveys under a cooperative program funded largely by the U.S. Energy Research and Development Administration. For each sample, the U.S. Geological Survey has quantitatively determined the amounts of 24 major, minor, and trace elements (including AI, As, Cd, Cu, F, Hg, Mn, Na, Pb, Se, U, and Zn), and has semiquantitatively determined the concentrations of 15 to 20 additional trace elements (including B, Be, Cr, Ge, Mo, Ni, and V). In addition, the U.S. Bureau of Mines has provided proximate and ultimate analyses, and Btu and forms-of-sulfur determinations on 488 of the samples. Statistical summaries of the data are given for all coal samples in the United States, for coal divided by rank (53 anthracite, 509 bituminous coal, 183 subbituminous coal, and 54 lignite samples), and the arithmetic means, ranges, and geometric means and deviations are given for the coal in each of seven different major coal areas in the United States. For example, the average coal in the United States contains 11.3 percent ash, 10.0 percent moisture, 2.0 percent sulfur, and has 11,180 Btu per pound; of the 10 major oxides determined on the 525?C ash, the average SiO2 content is 38 percent, Al2O3 20 percent, and Na2O 0.67 percent; the average Cd content is 7.3 ppm, Pb 114 ppm, and Zn 151 ppm (range 1 ppm to 6.0 percent). As determined on the raw coal, the average Hg content is 0.18 ppm (range <0.01 to 63.0 ppm), the Se content 4.1 ppm (range <0.1 to 150 ppm), and the U content 1.8 ppm (range <0.2 to 42.9 ppm).

  9. A direct method for e-cigarette aerosol sample collection.

    PubMed

    Olmedo, Pablo; Navas-Acien, Ana; Hess, Catherine; Jarmul, Stephanie; Rule, Ana

    2016-08-01

    E-cigarette use is increasing in populations around the world. Recent evidence has shown that the aerosol produced by e-cigarettes can contain a variety of toxicants. Published studies characterizing toxicants in e-cigarette aerosol have relied on filters, impingers or sorbent tubes, which are methods that require diluting or extracting the sample in a solution during collection. We have developed a collection system that directly condenses e-cigarette aerosol samples for chemical and toxicological analyses. The collection system consists of several cut pipette tips connected with short pieces of tubing. The pipette tip-based collection system can be connected to a peristaltic pump, a vacuum pump, or directly to an e-cigarette user for the e-cigarette aerosol to flow through the system. The pipette tip-based system condenses the aerosol produced by the e-cigarette and collects a liquid sample that is ready for analysis without the need of intermediate extraction solutions. We tested a total of 20 e-cigarettes from 5 different brands commercially available in Maryland. The pipette tip-based collection system condensed between 0.23 and 0.53mL of post-vaped e-liquid after 150 puffs. The proposed method is highly adaptable, can be used during field work and in experimental settings, and allows collecting aerosol samples from a wide variety of e-cigarette devices, yielding a condensate of the likely exact substance that is being delivered to the lungs.

  10. Collection requirements for trace-element analyses of extraterrestrial samples

    NASA Technical Reports Server (NTRS)

    Flynn, George J.; Sutton, S. R.

    1994-01-01

    Trace-element abundances have proven important in understanding the evolution of and interrelationships between different meteorites. Preliminary investigations of the trace-element contents of interplanetary dust particles indicate that trace-element abundances will prove equally important in distinguishing between micrometeorites of different types, comparing the interplanetary dust to the meteorites, and assessing the degree of thermal alteration experienced either on the parent body or during the collection process. Sample collection, delivery, and curation must be accomplished in a manner to avoid contamination with even trace amounts of the elements to be analyzed. The present SXRF sensitivity for micrometeorite analysis is of order 1 femtogram, but anticipated improvements in sensitivity will require sample contamination substantially below this level. Sample collection and handling equipment should be constructed from materials selected for ultrahigh purity, and serious consideration should be given in selecting the particular set of elements from which the collection apparatus is composed so as not to compromise useful information.

  11. A low cost multi-level sampling device for synchronous aseptic collection of environmental water samples.

    PubMed

    McCormick, Michael L; Banishki, Nikola; Powell, Sarah; Rumack, Amy; Garrett, Jinnie M

    2014-10-01

    We describe a simple device for the aseptic collection of environmental water samples at high spatial resolution to depths of 50m. To demonstrate the utility of this technique we present geochemical and archaeal community data from samples collected throughout the water column of a stratified lake.

  12. Methods for collection and analysis of water samples

    USGS Publications Warehouse

    Rainwater, Frank Hays; Thatcher, Leland Lincoln

    1960-01-01

    This manual contains methods used by the U.S. Geological Survey to collect, preserve, and analyze water samples. Throughout, the emphasis is on obtaining analytical results that accurately describe the chemical composition of the water in situ. Among the topics discussed are selection of sampling sites, frequency of sampling, field equipment, preservatives and fixatives, analytical techniques of water analysis, and instruments. Seventy-seven laboratory and field procedures are given for determining fifty-three water properties.

  13. On the improvement of blood sample collection at clinical laboratories

    PubMed Central

    2014-01-01

    Background Blood samples are usually collected daily from different collection points, such hospitals and health centers, and transported to a core laboratory for testing. This paper presents a project to improve the collection routes of two of the largest clinical laboratories in Spain. These routes must be designed in a cost-efficient manner while satisfying two important constraints: (i) two-hour time windows between collection and delivery, and (ii) vehicle capacity. Methods A heuristic method based on a genetic algorithm has been designed to solve the problem of blood sample collection. The user enters the following information for each collection point: postal address, average collecting time, and average demand (in thermal containers). After implementing the algorithm using C programming, this is run and, in few seconds, it obtains optimal (or near-optimal) collection routes that specify the collection sequence for each vehicle. Different scenarios using various types of vehicles have been considered. Unless new collection points are added or problem parameters are changed substantially, routes need to be designed only once. Results The two laboratories in this study previously planned routes manually for 43 and 74 collection points, respectively. These routes were covered by an external carrier company. With the implementation of this algorithm, the number of routes could be reduced from ten to seven in one laboratory and from twelve to nine in the other, which represents significant annual savings in transportation costs. Conclusions The algorithm presented can be easily implemented in other laboratories that face this type of problem, and it is particularly interesting and useful as the number of collection points increases. The method designs blood collection routes with reduced costs that meet the time and capacity constraints of the problem. PMID:24406140

  14. Development of a Sampling Collection Device with Diagnostic Procedures.

    PubMed

    Cheng, Jhih-Yan; Feng, Mow-Jung; Wu, Chia-Chi; Wang, Jane; Chang, Ting-Chang; Cheng, Chao-Min

    2016-08-02

    Cervicovaginal fluid plays an important role in the detection of many female genital diseases, but the lack of suitable collection devices in the market severely challenges test success rate. Appropriate clinical sampling devices for cervicovaginal fluid collection would help physicians detect diseases and disease states more rapidly, efficiently, and accurately. The objective of this study was to develop a readily usable sampling collection device that would eliminate macromolecular interference and accurately provide specimens for further studies. This study was designed to develop an effective device to collect cervicovaginal fluid from women with symptoms of endometrial lesions, women appearing in the clinic for a routine Papanicolaou smear, and/or women seeking a routine gynecologic checkup. Paper-based assay, ELISA, and qNano were used to provide accurate diagnoses. A total of 103 patients successfully used the developed device to collect cervicovaginal fluid. Some of the collected specimens were used to detect glycogen, lactate, and pH for determining pathogen infection. Other specimen samples were tested for the presence of female genital cancer by comparing interleukin 6 concentration and microvesicle concentration. We proposed a noninvasive screening test for the diagnosis of female genital diseases using a dual-material collection device. The outer, nonwoven fabric portion of this device was designed to filter macromolecules, and the inner cotton portion was designed to absorb cervicovaginal fluid.

  15. 52 additional reference population samples for the 55 AISNP panel.

    PubMed

    Pakstis, Andrew J; Haigh, Eva; Cherni, Lotfi; ElGaaied, Amel Ben Ammar; Barton, Alison; Evsanaa, Baigalmaa; Togtokh, Ariunaa; Brissenden, Jane; Roscoe, Janet; Bulbul, Ozlem; Filoglu, Gonul; Gurkan, Cemal; Meiklejohn, Kelly A; Robertson, James M; Li, Cai-Xia; Wei, Yi-Liang; Li, Hui; Soundararajan, Usha; Rajeevan, Haseena; Kidd, Judith R; Kidd, Kenneth K

    2015-11-01

    Ancestry inference for a person using a panel of SNPs depends on the variation of frequencies of those SNPs around the world and the amount of reference data available for calculation/comparison. The Kidd Lab panel of 55 AISNPs has been incorporated in commercial kits by both Life Technologies and Illumina for massively parallel sequencing. Therefore, a larger set of reference populations will be useful for researchers using those kits. We have added reference population allele frequencies for 52 population samples to the 73 previously entered so that there are now allele frequencies publicly available in ALFRED and FROG-kb for a total of 125 population samples.

  16. Astronaut Harrison Schmitt collects lunar rake samples during EVA

    NASA Technical Reports Server (NTRS)

    1972-01-01

    Scientist-Astronaut Harrison H. Schmitt collects lunar rake samples at Station 1 during the first Apollo 17 extravehicular activity (EVA-1) at the Taurus-Littrow landing site. This picture was taken by Astronatu Eugene Cernan, Apollo 17 commander. Schmitt is the lunar module pilot. The lunar rake, An Apollo lunar geology hand tool, is used to collect discrete samples of rocks and rock chips ranging in size from one-half inch (1.3 cm) to one inch (2.5 cm).

  17. Astronaut Harrison Schmitt collects lunar rake samples during EVA

    NASA Technical Reports Server (NTRS)

    1972-01-01

    Scientist-Astronaut Harrison H. Schmitt collects lunar rake samples at Station 1 during the first Apollo 17 extravehicular activity (EVA-1) at the Taurus-Littrow landing site. This picture was taken by Astronaut Eugene Cernan, Apollo 17 commander. Schmitt is the lunar module pilot. The lunar rake, an Apollo lunar geology hand tool, is used to collect discrete samples of rocks and rock chips ranging in size from one-half inch (1.3 cm) to one inch (2.5 cm).

  18. Apparatus and process for collection of gas and vapor samples

    DOEpatents

    Jackson, Dennis G.; Peterson, Kurt D.; Riha, Brian D.

    2008-04-01

    A gas sampling apparatus and process is provided in which a standard crimping tool is modified by an attached collar. The collar permits operation of the crimping tool while also facilitating the introduction of a supply of gas to be introduced into a storage vial. The introduced gas supply is used to purge ambient air from a collection chamber and an interior of the sample vial. Upon completion of the purging operation, the vial is sealed using the crimping tool.

  19. Macroinvertebrate community sample collection methods and data collected from Sand Creek and Medano Creek, Great Sand Dunes National Park and Preserve, Colorado, 2005–07

    USGS Publications Warehouse

    Ford, Morgan A.; Zuellig, Robert E.; Walters, David M.; Bruce, James F.

    2016-08-11

    This report provides a table of site descriptions, sample information, and semiquantitative aquatic macroinvertebrate data from 105 samples collected between 2005 and 2007 from 7 stream sites within the Sand Creek and Medano Creek watersheds in Great Sand Dunes National Park and Preserve, Saguache County, Colorado. Additionally, a short description of sample collection methods and laboratory sample processing procedures is presented. These data were collected in anticipation of assessing the potential effects of fish toxicants on macroinvertebrates.

  20. 78 FR 77119 - Proposed Information Collection Request; Comment Request; Regulation of Fuels and Fuel Additives...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-20

    ... AGENCY Proposed Information Collection Request; Comment Request; Regulation of Fuels and Fuel Additives: 2011 Renewable Fuel Standards-- Petition for International Aggregate Compliance Approach AGENCY... to submit an information collection request (ICR), ``Regulation of Fuels and Fuel Additives:...

  1. Assembly for collecting samples for purposes of identification or analysis and method of use

    DOEpatents

    Thompson, Cyril V [Knoxville, TN; Smith, Rob R [Knoxville, TN

    2010-02-02

    An assembly and an associated method for collecting a sample of material desired to be characterized with diagnostic equipment includes or utilizes an elongated member having a proximal end with which the assembly is manipulated by a user and a distal end. In addition, a collection tip which is capable of being placed into contact with the material to be characterized is supported upon the distal end. The collection tip includes a body of chemically-inert porous material for binding a sample of material when the tip is placed into contact with the material and thereby holds the sample of material for subsequent introduction to the diagnostic equipment.

  2. 7 CFR 160.22 - Collecting samples; issuing certificates.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Collecting samples; issuing certificates. 160.22 Section 160.22 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) NAVAL...

  3. 40 CFR 761.310 - Collecting the sample.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Collecting the sample. 761.310 Section 761.310 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND...

  4. Experimental Design for the INL Sample Collection Operational Test

    SciTech Connect

    Amidan, Brett G.; Piepel, Gregory F.; Matzke, Brett D.; Filliben, James J.; Jones, Barbara

    2007-12-13

    This document describes the test events and numbers of samples comprising the experimental design that was developed for the contamination, decontamination, and sampling of a building at the Idaho National Laboratory (INL). This study is referred to as the INL Sample Collection Operational Test. Specific objectives were developed to guide the construction of the experimental design. The main objective is to assess the relative abilities of judgmental and probabilistic sampling strategies to detect contamination in individual rooms or on a whole floor of the INL building. A second objective is to assess the use of probabilistic and Bayesian (judgmental + probabilistic) sampling strategies to make clearance statements of the form “X% confidence that at least Y% of a room (or floor of the building) is not contaminated. The experimental design described in this report includes five test events. The test events (i) vary the floor of the building on which the contaminant will be released, (ii) provide for varying or adjusting the concentration of contaminant released to obtain the ideal concentration gradient across a floor of the building, and (iii) investigate overt as well as covert release of contaminants. The ideal contaminant gradient would have high concentrations of contaminant in rooms near the release point, with concentrations decreasing to zero in rooms at the opposite end of the building floor. For each of the five test events, the specified floor of the INL building will be contaminated with BG, a stand-in for Bacillus anthracis. The BG contaminant will be disseminated from a point-release device located in the room specified in the experimental design for each test event. Then judgmental and probabilistic samples will be collected according to the pre-specified sampling plan. Judgmental samples will be selected based on professional judgment and prior information. Probabilistic samples will be selected in sufficient numbers to provide desired confidence

  5. Isotopic analysis of eggs: evaluating sample collection and preparation.

    PubMed

    Rock, Luc; Rowe, Sylwia; Czerwiec, Agnieszka; Richmond, Harold

    2013-02-15

    Egg traceability/authenticity is a worldwide concern. Stable isotope techniques have been suggested as a tool to address this issue. To further validate the use of these techniques, a research project was undertaken to evaluate what effect sample collection and preparation have on the measured isotopic composition of egg components. The timing of egg collection, the timing of egg preparation after collection, and the use of pasteurisation were investigated. The C, N, O, and S isotopic compositions of egg components from 7 different production systems were measured. Two sets of eggs were collected (4 months apart). It was found that the 'isotopic fingerprint' of a particular production system was maintained over time, and that it may be possible to trace liquid egg products based on isotopic data from fresh eggs. The findings from this study support the integration of stable isotope techniques in egg traceability/authenticity systems.

  6. Variability of collagen crosslinks: impact of sample collection period.

    PubMed

    Smith, S M; Dillon, E L; DeKerlegand, D E; Davis-Street, J E

    2004-04-01

    Because of the variability of collagen crosslinks, their use as markers for bone resorption is often criticized. We hypothesized that the variability could be reduced by collecting urine for 24 hours (or longer) instead of using single voids, and by not normalizing to creatinine. Urine samples were collected from 22 healthy subjects during two or more 24-hour periods. Each 24-hour pool and each 2nd void of the day were analyzed for N-telopeptide (NTX), pyridinium (PYD), and deoxypyridinoline (DPD) crosslinks. Data were analyzed by using linear regression. For NTX, R2 for the two, 2nd-void samples (n = 38) was 0.55, whereas R2 for the two 24-hour pools was 0.51 or 0.52, expressed per day or per creatinine. For PYD and DPD, R2 for the 2nd-void samples was 0.26 and 0.18, R2 for the 24-hour pools expressed per day was 0.58 and 0.74, and R2 for the 24-hour pools expressed per creatinine was 0.65 and 0.76, respectively. Regression of the 2nd void and the corresponding 24-hour pool, expressed per day, yielded R2 = 0.19, 0.19, and 0.08, for NTX, PYD, and DPD, respectively (n = 76 each). For the 2nd-void sample and its corresponding 24-hour pool, expressed per creatinine, R2 = 0.24, 0.33, and 0.08, respectively. In a separate study, the coefficient of variation for NTX was reduced (P < 0.05) when data from more than one 24-hour collection were combined. Thus, the variability inherent in crosslink determinations can be reduced by collecting urine for longer periods. In research studies, the high variability of single-void collections, compounded by creatinine normalization, may alter or obscure findings.

  7. Variability of collagen crosslinks: impact of sample collection period

    NASA Technical Reports Server (NTRS)

    Smith, S. M.; Dillon, E. L.; DeKerlegand, D. E.; Davis-Street, J. E.

    2004-01-01

    Because of the variability of collagen crosslinks, their use as markers for bone resorption is often criticized. We hypothesized that the variability could be reduced by collecting urine for 24 hours (or longer) instead of using single voids, and by not normalizing to creatinine. Urine samples were collected from 22 healthy subjects during two or more 24-hour periods. Each 24-hour pool and each 2nd void of the day were analyzed for N-telopeptide (NTX), pyridinium (PYD), and deoxypyridinoline (DPD) crosslinks. Data were analyzed by using linear regression. For NTX, R2 for the two, 2nd-void samples (n = 38) was 0.55, whereas R2 for the two 24-hour pools was 0.51 or 0.52, expressed per day or per creatinine. For PYD and DPD, R2 for the 2nd-void samples was 0.26 and 0.18, R2 for the 24-hour pools expressed per day was 0.58 and 0.74, and R2 for the 24-hour pools expressed per creatinine was 0.65 and 0.76, respectively. Regression of the 2nd void and the corresponding 24-hour pool, expressed per day, yielded R2 = 0.19, 0.19, and 0.08, for NTX, PYD, and DPD, respectively (n = 76 each). For the 2nd-void sample and its corresponding 24-hour pool, expressed per creatinine, R2 = 0.24, 0.33, and 0.08, respectively. In a separate study, the coefficient of variation for NTX was reduced (P < 0.05) when data from more than one 24-hour collection were combined. Thus, the variability inherent in crosslink determinations can be reduced by collecting urine for longer periods. In research studies, the high variability of single-void collections, compounded by creatinine normalization, may alter or obscure findings.

  8. 77 FR 67655 - Agency Information Collection Activities; Proposed Collection; Comment Request; Food Additive...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-13

    ...) Moderate Category: For a food additive petition without complex chemistry, manufacturing, efficacy, or...) Complex Category: For a food additive petition with complex chemistry, manufacturing, efficacy, and/or... investigational food additive file without complex chemistry, manufacturing, efficacy, or safety issues,...

  9. Collection of Stratospheric Samples using Balloon-Borne Payload System

    NASA Astrophysics Data System (ADS)

    Prakash, Ajin; Safonova, Margarita; Murthy, Jayant; Sreejith, A. G.; Kumble, Sheshashayi; Mathew, Joice; Sarpotdar, Mayuresh; Kj, Nirmal; Suresh, Ambily; Chakravortty, Dipshikha; Rangarajan, Annapoorni

    2016-07-01

    Earth's atmosphere at stratospheric altitudes contains dust particles from soil lifted by weather, volcanic dust, man-made aerosols, IDP (Interplanetary Dust Particles) - remnants of comets and asteroids, and even interstellar dust. Satellite observations suggest that approximately 100--300 tons of cosmic dust enter Earth's atmosphere every day. However, very little is known about the microbial life in the upper atmosphere, where conditions are very much similar to that on Mars and possibly on some exoplanets. Stratosphere provides a good opportunity to study the existence or survival of biological life in these conditions. Despite the importance of this topic to astrobiology, stratospheric microbial diversity/survival remains largely unexplored, probably due to significant difficulties in the access and ensuring the absence of contamination of the samples. To conduct a detailed study into this, we are developing the balloon-borne payload system SAMPLE (Stratospheric Altitude Microbiology Probe for Life Existence) to collect dust samples from stratosphere and bring them in an hygienic and uncontaminated manner to a suitable laboratory environment, where further study will be conducted to establish the possibility of microbial life in the upper atmosphere. This balloon-borne payload system will rise through the atmosphere till it reaches an altitude of about 25-30 km above sea level. The payload consists of detachable pre-sterilized sampling chambers designed to collect and contain the dust samples and get them back to the surface without contamination during the flight, a microprocessor and a controller which will determine the altitude of the payload system to actively monitor the opening and closing of the sample collection chambers. For contamination control, we will have two extra chambers, one of which will fly but not open, and one will remain closed on the ground. Other onboard devices include environmental sensors, GPS tracking devices, cameras to monitor

  10. 76 FR 80377 - Notice of Submission of Proposed Information Collection to OMB Additional On-Site Data Collection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-23

    ... of Submission of Proposed Information Collection to OMB Additional On-Site Data Collection for the... HCV programs. The proposed data collection will take place through site visits to up to 30 PHAs and... the PHA. The results of the site visits will be used to identify PHAs to participate in a...

  11. The GENESIS Solar-Wind Sample: Summary of In-Situ Spacecraft Measurements During the Sample Collection Period

    NASA Astrophysics Data System (ADS)

    Reisenfeld, D. B.; Steinberg, J. T.; Wiens, R. C.; Barraclough, B. L.; Zurbuchen, T. H.; Burnett, D. S.

    2004-12-01

    The GENESIS mission returned samples of solar wind to earth on September 8. These samples were collected between 30-Nov-2001 and 01-Apr-2004 at the L1 point on ultrapure substrates that are being analyzed using various laboratory techniques. The primary purpose of the GENESIS mission is to determine to unprecedented accuracy (e.g., ±1%-0.1%, 2σ ) the isotopic composition of the solar wind, and by extension, of the Sun, particularly for oxygen, nitrogen, carbon, and the noble gases. In addition to a continuously-collected sample, separate samples of the different regimes-coronal hole (CH), interstream (IS), and coronal mass ejection (CME)-were collected to help deconvolve any fine-scale isotopic fractionation associated with solar-wind ionization and acceleration. The four different samples (3 regimes plus one cumulative sample) are long-term averages over varying solar-wind conditions, and need to be understood within the context of other measurements besides those that can be made on the substrates themselves. These include charge state, v, T, density, and magnetic field data. Additionally, comparisons of in-situ elemental composition measurements with the measurements made on GENESIS samples will be useful in validating the different measurement techniques. For these reasons, we are compiling a database of conditions as measured by in-situ spacecraft instruments stationed at L1 over the time period of the GENESIS sample collection. Comparison with ACE/SWICS elemental and charge-state abundances confirmed early in the GENESIS mission that the GENESIS regime-selection algorithm was successfully isolating the CME material, protecting the CH and IS samples from CME contamination. The data also demonstrate the discrimination between IS and CH flow types based mostly on solar-wind speed, but allowing compensation for evolution effects due to the transit to 1 AU.

  12. Fluid sample collection and distribution system. [qualitative analysis of aqueous samples from several points

    NASA Technical Reports Server (NTRS)

    Brooks, R. L. (Inventor)

    1979-01-01

    A multipoint fluid sample collection and distribution system is provided wherein the sample inputs are made through one or more of a number of sampling valves to a progressive cavity pump which is not susceptible to damage by large unfiltered particles. The pump output is through a filter unit that can provide a filtered multipoint sample. An unfiltered multipoint sample is also provided. An effluent sample can be taken and applied to a second progressive cavity pump for pumping to a filter unit that can provide one or more filtered effluent samples. The second pump can also provide an unfiltered effluent sample. Means are provided to periodically back flush each filter unit without shutting off the whole system.

  13. Device for collecting and analyzing matrix-isolated samples

    DOEpatents

    Reedy, Gerald T.

    1979-01-01

    A gas-sample collection device is disclosed for matrix isolation of individual gas bands from a gas chromatographic separation and for presenting these distinct samples for spectrometric examination. The device includes a vacuum chamber containing a rotatably supported, specular carrousel having a number of external, reflecting surfaces around its axis of rotation for holding samples. A gas inlet is provided for depositing sample and matrix material on the individual reflecting surfaces maintained at a sufficiently low temperature to cause solidification. Two optical windows or lenses are installed in the vacuum chamber walls for transmitting a beam of electromagnetic radiation, for instance infrared light, through a selected sample. Positioned within the chamber are two concave mirrors, the first aligned to receive the light beam from one of the lenses and focus it to the sample on one of the reflecting surfaces of the carrousel. The second mirror is aligned to receive reflected light from that carrousel surface and to focus it outwardly through the second lens. The light beam transmitted from the sample is received by a spectrometer for determining absorption spectra.

  14. Experimental and Sampling Design for the INL-2 Sample Collection Operational Test

    SciTech Connect

    Piepel, Gregory F.; Amidan, Brett G.; Matzke, Brett D.

    2009-02-16

    This report describes the experimental and sampling design developed to assess sampling approaches and methods for detecting contamination in a building and clearing the building for use after decontamination. An Idaho National Laboratory (INL) building will be contaminated with BG (Bacillus globigii, renamed Bacillus atrophaeus), a simulant for Bacillus anthracis (BA). The contamination, sampling, decontamination, and re-sampling will occur per the experimental and sampling design. This INL-2 Sample Collection Operational Test is being planned by the Validated Sampling Plan Working Group (VSPWG). The primary objectives are: 1) Evaluate judgmental and probabilistic sampling for characterization as well as probabilistic and combined (judgment and probabilistic) sampling approaches for clearance, 2) Conduct these evaluations for gradient contamination (from low or moderate down to absent or undetectable) for different initial concentrations of the contaminant, 3) Explore judgment composite sampling approaches to reduce sample numbers, 4) Collect baseline data to serve as an indication of the actual levels of contamination in the tests. A combined judgmental and random (CJR) approach uses Bayesian methodology to combine judgmental and probabilistic samples to make clearance statements of the form "X% confidence that at least Y% of an area does not contain detectable contamination” (X%/Y% clearance statements). The INL-2 experimental design has five test events, which 1) vary the floor of the INL building on which the contaminant will be released, 2) provide for varying the amount of contaminant released to obtain desired concentration gradients, and 3) investigate overt as well as covert release of contaminants. Desirable contaminant gradients would have moderate to low concentrations of contaminant in rooms near the release point, with concentrations down to zero in other rooms. Such gradients would provide a range of contamination levels to challenge the sampling

  15. Apollo 17 Astronaut Harrison Schmitt Collects Lunar Rock Samples

    NASA Technical Reports Server (NTRS)

    1972-01-01

    In this Apollo 17 onboard photo, Lunar Module pilot Harrison H. Schmitt collects rock samples from a huge boulder near the Valley of Tourus-Littrow on the lunar surface. The seventh and last manned lunar landing and return to Earth mission, the Apollo 17, carrying a crew of three astronauts: Schmitt; Mission Commander Eugene A. Cernan; and Command Module pilot Ronald E. Evans, lifted off on December 7, 1972 from the Kennedy Space Flight Center (KSC). Scientific objectives of the Apollo 17 mission included geological surveying and sampling of materials and surface features in a preselected area of the Taurus-Littrow region, deploying and activating surface experiments, and conducting in-flight experiments and photographic tasks during lunar orbit and transearth coast (TEC). These objectives included: Deployed experiments such as the Apollo lunar surface experiment package (ALSEP) with a Heat Flow experiment, Lunar seismic profiling (LSP), Lunar surface gravimeter (LSG), Lunar atmospheric composition experiment (LACE) and Lunar ejecta and meteorites (LEAM). The mission also included Lunar Sampling and Lunar orbital experiments. Biomedical experiments included the Biostack II Experiment and the BIOCORE experiment. The mission marked the longest Apollo mission, 504 hours, and the longest lunar surface stay time, 75 hours, which allowed the astronauts to conduct an extensive geological investigation. They collected 257 pounds (117 kilograms) of lunar samples with the use of the Marshall Space Flight Center designed Lunar Roving Vehicle (LRV). The mission ended on December 19, 1972

  16. Plume Collection Strategies for Icy World Sample Return

    NASA Technical Reports Server (NTRS)

    Neveu, M.; Glavin, D. P.; Tsou, P.; Anbar, A. D.; Williams, P.

    2015-01-01

    Three icy worlds in the solar system display evidence of pluming activity. Water vapor and ice particles emanate from cracks near the south pole of Saturn's moon Enceladus. The plume gas contains simple hydrocarbons that could be fragments of larger, more complex organics. More recently, observations using the Hubble and Herschel space telescopes have hinted at transient water vapor plumes at Jupiter's moon Europa and the dwarf planet Ceres. Plume materials may be ejected directly from possible sub-surface oceans, at least on Enceladus. In such oceans, liquid water, organics, and energy may co-exist, making these environments habitable. The venting of habitable ocean material into space provides a unique opportunity to capture this material during a relatively simple flyby mission and return it to Earth. Plume collection strategies should enable investigations of evidence for life in the returned samples via laboratory analyses of the structure, distribution, isotopic composition, and chirality of the chemical components (including biomolecules) of plume materials. Here, we discuss approaches for the collection of dust and volatiles during flybys through Enceladus' plume, based on Cassini results and lessons learned from the Stardust comet sample return mission. We also highlight areas where sample collector and containment technology development and testing may be needed for future plume sample return missions.

  17. Appendix C. Collection of Samples for Chemical Agent Analysis

    SciTech Connect

    Koester, C; Thompson, C; Doerr, T; Scripsick, R

    2005-09-23

    This chapter describes procedures for the collection and analysis of samples of various matrices for the purpose of determining the presence of chemical agents in a civilian setting. This appendix is intended to provide the reader with sufficient information to make informed decisions about the sampling and analysis process and to suggest analytical strategies that might be implemented by the scientists performing sampling and analysis. This appendix is not intended to be used as a standard operating procedure to provide detailed instructions as to how trained scientists should handle samples. Chemical agents can be classified by their physical and chemical properties. Table 1 lists the chemical agents considered by this report. In selecting sampling and analysis methods, we have considered procedures proposed by the Organization for Prohibition of Chemical Weapons (OPCW), the U. S. Environmental Protection Agency (EPA), and peer-reviewed scientific literature. EPA analytical methods are good resources describing issues of quality assurance with respect to chain-of-custody, sample handling, and quality control requirements.

  18. Lunar Samples: Apollo Collection Tools, Curation Handling, Surveyor III and Soviet Luna Samples

    NASA Technical Reports Server (NTRS)

    Allton, J.H.

    2009-01-01

    The 6 Apollo missions that landed on the lunar surface returned 2196 samples comprised of 382 kg. The 58 samples weighing 21.5 kg collected on Apollo 11 expanded to 741 samples weighing 110.5 kg by the time of Apollo 17. The main goal on Apollo 11 was to obtain some material and return it safely to Earth. As we gained experience, the sampling tools and a more specific sampling strategy evolved. A summary of the sample types returned is shown in Table 1. By year 1989, some statistics on allocation by sample type were compiled [2]. The "scientific interest index" is based on the assumption that the more allocations per gram of sample, the higher the scientific interest. It is basically a reflection of the amount of diversity within a given sample type. Samples were also set aside for biohazard testing. The samples set aside and used for biohazard testing were represen-tative, as opposed to diverse. They tended to be larger and be comprised of less scientifically valuable mate-rial, such as dust and debris in the bottom of sample containers.

  19. 76 FR 34639 - Notice of Proposed Additional Information Collection: Advisory Committee and Research and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-14

    ... Notice of Proposed Additional Information Collection: Advisory Committee and Research and Promotion... approved information collection of the Advisory Committee and Research and Promotion Background Information... . SUPPLEMENTARY INFORMATION: Title: Advisory Committee and Research and Promotion Background Information....

  20. New additions to the National Plant Germplasm System's Beta collection: Southern Morocco collection

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The USDA Agricultural Research Service’s National Plant Germplasm System’s (NPGS) Beta collection is comprised of 2,541 accessions from 14 species. The largest number of accessions is from Beta vulgaris ssp. vulgaris, (domesticated beet crops – table, leaf (Swiss chard), fodder and, primarily, sugar...

  1. Planning Considerations Related to Collecting and Analyzing Samples of the Martian Soils

    NASA Technical Reports Server (NTRS)

    Liu, Yang; Mellon, Mike T.; Ming, Douglas W.; Morris, Richard V.; Noble, Sarah K.; Sullivan, Robert J.; Taylor, Lawrence A.; Beaty, David W.

    2014-01-01

    The Mars Sample Return (MSR) End-to-End International Science Analysis Group (E2E-iSAG [1]) established scientific objectives associ-ated with Mars returned-sample science that require the return and investigation of one or more soil samples. Soil is defined here as loose, unconsolidated materials with no implication for the presence or absence of or-ganic components. The proposed Mars 2020 (M-2020) rover is likely to collect and cache soil in addition to rock samples [2], which could be followed by future sample retrieval and return missions. Here we discuss key scientific consid-erations for sampling and caching soil samples on the proposed M-2020 rover, as well as the state in which samples would need to be preserved when received by analysts on Earth. We are seeking feedback on these draft plans as input to mission requirement formulation. A related planning exercise on rocks is reported in an accompanying abstract [3].

  2. Falcon: Visual analysis of large, irregularly sampled, and multivariate time series data in additive manufacturing

    DOE PAGES

    Steed, Chad A.; Halsey, William; Dehoff, Ryan; ...

    2017-02-16

    Flexible visual analysis of long, high-resolution, and irregularly sampled time series data from multiple sensor streams is a challenge in several domains. In the field of additive manufacturing, this capability is critical for realizing the full potential of large-scale 3D printers. Here, we propose a visual analytics approach that helps additive manufacturing researchers acquire a deep understanding of patterns in log and imagery data collected by 3D printers. Our specific goals include discovering patterns related to defects and system performance issues, optimizing build configurations to avoid defects, and increasing production efficiency. We introduce Falcon, a new visual analytics system thatmore » allows users to interactively explore large, time-oriented data sets from multiple linked perspectives. Falcon provides overviews, detailed views, and unique segmented time series visualizations, all with adjustable scale options. To illustrate the effectiveness of Falcon at providing thorough and efficient knowledge discovery, we present a practical case study involving experts in additive manufacturing and data from a large-scale 3D printer. The techniques described are applicable to the analysis of any quantitative time series, though the focus of this paper is on additive manufacturing.« less

  3. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF FLOOR DUST SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.19)

    EPA Science Inventory

    This SOP describes the method for collecting a floor dust sample from carpet. Dust samples will be collected in the room that the child uses most at home and/or at day care using a High Volume Small Surface Sampler (HVS3). In addition, participants will also be asked to donate a ...

  4. Extravehicular Activity Asteroid Exploration and Sample Collection Capability

    NASA Technical Reports Server (NTRS)

    Scoville, Zebulon; Sipila, Stephanie; Bowie, Jonathan

    2014-01-01

    NASA's Asteroid Redirect Crewed Mission (ARCM) is challenged with primary mission objectives of demonstrating deep space Extravehicular Activity (EVA) and tools, and obtaining asteroid samples to return to Earth for further study. Although the Modified Advanced Crew Escape Suit (MACES) is used for the EVAs, it has limited mobility which increases fatigue and decreases the crews' capability to perform EVA tasks. Furthermore, previous Shuttle and International Space Station (ISS) spacewalks have benefited from EVA interfaces which have been designed and manufactured on Earth. Rigid structurally mounted handrails, and tools with customized interfaces and restraints optimize EVA performance. For ARCM, some vehicle interfaces and tools can leverage heritage designs and experience. However, when the crew ventures onto an asteroid capture bag to explore the asteroid and collect rock samples, EVA complexity increases due to the uncertainty of the asteroid properties. The variability of rock size, shape and composition, as well as bunching of the fabric bag will complicate EVA translation, tool restraint and body stabilization. The unknown asteroid hardness and brittleness will complicate tool use. The rock surface will introduce added safety concerns for cut gloves and debris control. Feasible solutions to meet ARCM EVA objectives were identified using experience gained during Apollo, Shuttle, and ISS EVAs, terrestrial mountaineering practices, NASA Extreme Environment Mission Operations (NEEMO) 16 mission, and during Neutral Buoyancy Laboratory testing in the MACES suit. The proposed concept utilizes expandable booms and integrated features of the asteroid capture bag to position and restrain the crew at the asteroid worksite. These methods enable the capability to perform both finesse, and high load tasks necessary to collect samples for scientific characterization of the asteroid. This paper will explore the design trade space and options that were examined for EVA, the

  5. Sulfate and nitrate collected by filter sampling near the tropopause

    NASA Technical Reports Server (NTRS)

    Humenik, F. M.; Lezberg, E. A.; Otterson, D. A.

    1980-01-01

    Filter samples collected near the tropopause with an F-106 aircraft and two Boeing 747 aircraft were analyzed for sulfate and nitrate ion content. Within the range of routine commercial flight altitudes (at or below 12.5 km), stratospheric mass mixing ratios for the winter-spring group averaged 0.26 ppbm for sulfate and 0.35 ppbm for nitrate. For the summer-fall group, stratosphere mixing ratios averaged 0.13 ppbm and 0.25 ppbm for sulfate and nitrate, respectively. Winter-spring group tropospheric mass mixing ratios averaged 0.08 ppbm for sulfate and 0.10 ppbm for nitrate, while summer-fall group tropospheric mixing ratios averaged 0.05 ppbm for sulfate and 0.08 ppbm for nitrate. Correlations of the filter data with available ozone data suggest that the sulfate and nitrate are transported from the stratosphere to the troposphere.

  6. Seminal plasma anti-sperm antibodies and IVF: the effect of semen sample collection into 50% serum.

    PubMed

    Elder, K T; Wick, K L; Edwards, R G

    1990-02-01

    A retrospective analysis was carried out which studied IVF results for couples in whom the male partner had anti-sperm antibodies in seminal plasma, as judged by a positive MAR test. Of the 59 couples studied over a total of 113 cycles, 30 had IVF semen samples collected into sterile, dry pots. Thirty-eight of the couples had samples collected into medium containing 50% serum, and nine couples underwent separate treatment cycles with samples collected both dry and into 50% serum. The results demonstrate that the addition of serum to sample collection pots significantly improves the oocyte fertilization rate and is followed by a greater chance of conception for these couples.

  7. DS — Software for analyzing data collected using double sampling

    USGS Publications Warehouse

    Bart, Jonathan; Hartley, Dana

    2011-01-01

    DS analyzes count data to estimate density or relative density and population size when appropriate. The software is available at http://iwcbm.dev4.fsr.com/IWCBM/default.asp?PageID=126. The software was designed to analyze data collected using double sampling, but it also can be used to analyze index data. DS is not currently configured to apply distance methods or methods based on capture-recapture theory. Double sampling for the purpose of this report means surveying a sample of locations with a rapid method of unknown accuracy and surveying a subset of these locations using a more intensive method assumed to yield unbiased estimates. "Detection ratios" are calculated as the ratio of results from rapid surveys on intensive plots to the number actually present as determined from the intensive surveys. The detection ratios are used to adjust results from the rapid surveys. The formula for density is (results from rapid survey)/(estimated detection ratio from intensive surveys). Population sizes are estimated as (density)(area). Double sampling is well-established in the survey sampling literature—see Cochran (1977) for the basic theory, Smith (1995) for applications of double sampling in waterfowl surveys, Bart and Earnst (2002, 2005) for discussions of its use in wildlife studies, and Bart and others (in press) for a detailed account of how the method was used to survey shorebirds across the arctic region of North America. Indices are surveys that do not involve complete counts of well-defined plots or recording information to estimate detection rates (Thompson and others, 1998). In most cases, such data should not be used to estimate density or population size but, under some circumstances, may be used to compare two densities or estimate how density changes through time or across space (Williams and others, 2005). The Breeding Bird Survey (Sauer and others, 2008) provides a good example of an index survey. Surveyors record all birds detected but do not record

  8. Water column and bed-sediment core samples collected from Brownlee Reservoir near Oxbow, Oregon, 2012

    USGS Publications Warehouse

    Fosness, Ryan L.; Naymik, Jesse; Hopkins, Candice B.; DeWild, John F.

    2013-01-01

    The U.S. Geological Survey, in cooperation with Idaho Power Company, collected water-column and bed-sediment core samples from eight sites in Brownlee Reservoir near Oxbow, Oregon, during May 5–7, 2012. Water-column and bed-sediment core samples were collected at each of the eight sites and analyzed for total mercury and methylmercury. Additional bed-sediment core samples, collected from three of the eight sites, were analyzed for pesticides and other organic compounds, trace metals, and physical characteristics, such as particle size. Total mercury and methylmercury were detected in each of the water column and bed-sediment core samples. Only 17 of the 417 unique pesticide and organic compounds were detected in bed-sediment core samples. Concentrations of most organic wastewater compounds detected in bed sediment were less than the reporting level. Trace metals detected were greater than the reporting level in all the bed-sediment core samples submitted for analysis. The particle size distribution of bed-sediment core samples was predominantly clay mixed with silt.

  9. The Importance of Meteorite Collections to Sample Return Missions: Past, Present, and Future Considerations

    NASA Technical Reports Server (NTRS)

    Welzenbach, L. C.; McCoy, T. J.; Glavin, D. P.; Dworkin, J. P.; Abell, P. A.

    2012-01-01

    While much of the scientific community s current attention is drawn to sample return missions, it is the existing meteorite and cosmic dust collections that both provide the paradigms to be tested by these missions and the context for interpreting the results. Recent sample returns from the Stardust and Hayabusa missions provided us with new materials and insights about our Solar System history and processes. As an example, Stardust sampled CAIs among the population of cometary grains, requiring extensive and unexpected radial mixing in the early solar nebula. This finding would not have been possible, however, without extensive studies of meteoritic CAIs that established their high-temperature, inner Solar System formation. Samples returned by Stardust also revealed the first evidence of a cometary amino acid, a discovery that would not have been possible with current in situ flight instrument technology. The Hayabusa mission provided the final evidence linking ordinary chondrites and S asteroids, a hypothesis that developed from centuries of collection and laboratory and ground-based telescopic studies. In addition to these scientific findings, studies of existing meteorite collections have defined and refined the analytical techniques essential to studying returned samples. As an example, the fortuitous fall of the Allende CV3 and Murchison CM2 chondrites within months before the return of Apollo samples allowed testing of new state-of-the-art analytical facilities. The results of those studies not only prepared us to better study lunar materials, but unanticipated discoveries changed many of our concepts about the earliest history and processes of the solar nebula. This synergy between existing collections and future space exploration is certainly not limited to sample return missions. Laboratory studies confirmed the existence of meteorites from Mars and raised the provocative possibility of preservation of ancient microbial life. The laboratory studies in

  10. 78 FR 52803 - Agency Information Collection Activities; Submission for OMB Review; Comment Request; Additional...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-26

    ... OMB under the PRA and displays a currently valid OMB Control Number. In addition, notwithstanding any... collection of information that does not display a valid Control Number. See 5 CFR 1320.5(a) and 1320.6. The DOL obtains OMB approval for this information collection under Control Number 1218-0237....

  11. 40 CFR 80.8 - Sampling methods for gasoline, diesel fuel, fuel additives, and renewable fuels.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... fuel, fuel additives, and renewable fuels. 80.8 Section 80.8 Protection of Environment ENVIRONMENTAL... Provisions § 80.8 Sampling methods for gasoline, diesel fuel, fuel additives, and renewable fuels. The..., blendstocks, fuel additives and renewable fuels for purposes of determining compliance with the...

  12. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF URINE SAMPLES (SOP-2.14)

    EPA Science Inventory

    This SOP describes the method for collecting urine samples from the study participants (children and their primary caregivers). Urine samples will be approximate 48-hr collections, collected as spot urine samples accumulated over the 48-hr sampling period. If the household or da...

  13. The Autism Simplex Collection: an international, expertly phenotyped autism sample for genetic and phenotypic analyses

    PubMed Central

    2014-01-01

    Background There is an urgent need for expanding and enhancing autism spectrum disorder (ASD) samples, in order to better understand causes of ASD. Methods In a unique public-private partnership, 13 sites with extensive experience in both the assessment and diagnosis of ASD embarked on an ambitious, 2-year program to collect samples for genetic and phenotypic research and begin analyses on these samples. The program was called The Autism Simplex Collection (TASC). TASC sample collection began in 2008 and was completed in 2010, and included nine sites from North America and four sites from Western Europe, as well as a centralized Data Coordinating Center. Results Over 1,700 trios are part of this collection, with DNA from transformed cells now available through the National Institute of Mental Health (NIMH). Autism Diagnostic Interview-Revised (ADI-R) and Autism Diagnostic Observation Schedule-Generic (ADOS-G) measures are available for all probands, as are standardized IQ measures, Vineland Adaptive Behavioral Scales (VABS), the Social Responsiveness Scale (SRS), Peabody Picture Vocabulary Test (PPVT), and physical measures (height, weight, and head circumference). At almost every site, additional phenotypic measures were collected, including the Broad Autism Phenotype Questionnaire (BAPQ) and Repetitive Behavior Scale-Revised (RBS-R), as well as the non-word repetition scale, Communication Checklist (Children’s or Adult), and Aberrant Behavior Checklist (ABC). Moreover, for nearly 1,000 trios, the Autism Genome Project Consortium (AGP) has carried out Illumina 1 M SNP genotyping and called copy number variation (CNV) in the samples, with data being made available through the National Institutes of Health (NIH). Whole exome sequencing (WES) has been carried out in over 500 probands, together with ancestry matched controls, and this data is also available through the NIH. Additional WES is being carried out by the Autism Sequencing Consortium (ASC), where the

  14. Apollo Lunar Sample Photographs: Digitizing the Moon Rock Collection

    NASA Astrophysics Data System (ADS)

    Lofgren, G. E.; Todd, N. S.; Runco, S. K.; Stefanov, W. L.

    2011-03-01

    JSC curation is digitizing pictures of lunar samples taken during initial sample return and subsequent processing. These images will be available via a searchable database on the Curation website as they are produced; 69% are currently available.

  15. Evidence That Certain Waste Tank Headspace Vapor Samples Were Contaminated by Semivolatile Polymer Additives

    SciTech Connect

    Huckaby, James L.

    2006-02-09

    Vapor samples collected from the headspaces of the Hanford Site high-level radioactive waste tanks in 1994 and 1995 using the Vapor Sampling System (VSS) were reported to contain trace levels of phthalates, antioxidants, and certain other industrial chemicals that did not have a logical origin in the waste. This report examines the evidence these chemicals were sampling artifacts (contamination) and identifies the chemicals reported as headspace constituents that may instead have been contaminants. Specific recommendations are given regarding the marking of certain chemicals as suspect on the basis they were sampling manifold contaminants.

  16. 49 CFR 199.111 - Retention of samples and additional testing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.111 Retention of samples and additional testing. (a...) Since some analytes may deteriorate during storage, detected levels of the drug below the...

  17. 49 CFR 199.111 - Retention of samples and additional testing.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.111 Retention of samples and additional testing. (a...) Since some analytes may deteriorate during storage, detected levels of the drug below the...

  18. Additives

    NASA Technical Reports Server (NTRS)

    Smalheer, C. V.

    1973-01-01

    The chemistry of lubricant additives is discussed to show what the additives are chemically and what functions they perform in the lubrication of various kinds of equipment. Current theories regarding the mode of action of lubricant additives are presented. The additive groups discussed include the following: (1) detergents and dispersants, (2) corrosion inhibitors, (3) antioxidants, (4) viscosity index improvers, (5) pour point depressants, and (6) antifouling agents.

  19. [From project-based sample collection to biobank].

    PubMed

    Baranyai, Zsolt; Mersich, Tamás; Dede, Kristóf; Besznyák, István; Zaránd, Attila; Teknos, Dániel; Nagy, Péter; Salamon, Ferenc; Nagy, Pál; Nagy, Zsolt; Kótai, Zsuzsanna; Szász, Marcell; Lukács, Lilla; Szállási, Zoltán; Jósa, Valéria; Jakab, Ferenc

    2011-04-10

    The research group takes samples for molecular genetical examinations from tumors removed during operations within ischemic time interval. Samples are stored in liquid nitrogen. Clinical data of these patients are recorded in an informatics system developed by the group. Patients are followed in an out-patient clinic set up for this purpose not financed by the National Health Insurance Fund. Tissue samples and follow up data are used to cooperate with molecular genetical laboratories.

  20. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false OTC test sample collection systems for drugs of... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a...

  1. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false OTC test sample collection systems for drugs of... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a...

  2. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false OTC test sample collection systems for drugs of... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a...

  3. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false OTC test sample collection systems for drugs of... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a...

  4. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false OTC test sample collection systems for drugs of... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a...

  5. DEVELOPMENT OF A TAMPER RESISTANT/INDICATING AEROSOL COLLECTION SYSTEM FOR ENVIRONMENTAL SAMPLING AT BULK HANDLING FACILITIES

    SciTech Connect

    Sexton, L.

    2012-06-06

    Environmental sampling has become a key component of International Atomic Energy Agency (IAEA) safeguards approaches since its approval for use in 1996. Environmental sampling supports the IAEA's mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a Nation State. Swipe sampling is the most commonly used method for the collection of environmental samples from bulk handling facilities. However, augmenting swipe samples with an air monitoring system, which could continuously draw samples from the environment of bulk handling facilities, could improve the possibility of the detection of undeclared activities. Continuous sampling offers the opportunity to collect airborne materials before they settle onto surfaces which can be decontaminated, taken into existing duct work, filtered by plant ventilation, or escape via alternate pathways (i.e. drains, doors). Researchers at the Savannah River National Laboratory and Oak Ridge National Laboratory have been working to further develop an aerosol collection technology that could be installed at IAEA safeguarded bulk handling facilities. The addition of this technology may reduce the number of IAEA inspector visits required to effectively collect samples. The principal sample collection device is a patented Aerosol Contaminant Extractor (ACE) which utilizes electrostatic precipitation principles to deposit particulates onto selected substrates. Recent work has focused on comparing traditional swipe sampling to samples collected via an ACE system, and incorporating tamper resistant and tamper indicating (TRI) technologies into the ACE system. Development of a TRI-ACE system would allow collection of samples at uranium/plutonium bulk handling facilities in a manner that ensures sample integrity and could be an important addition to the international nuclear safeguards inspector's toolkit. This work was supported by the Next Generation Safeguards Initiative (NGSI), Office

  6. Optimized sample preparation of endoscopic collected pancreatic fluid for SDS-PAGE analysis.

    PubMed

    Paulo, Joao A; Lee, Linda S; Wu, Bechien; Repas, Kathryn; Banks, Peter A; Conwell, Darwin L; Steen, Hanno

    2010-07-01

    The standardization of methods for human body fluid protein isolation is a critical initial step for proteomic analyses aimed to discover clinically relevant biomarkers. Several caveats have hindered pancreatic fluid proteomics, including the heterogeneity of samples and protein degradation. We aim to optimize sample handling of pancreatic fluid that has been collected using a safe and effective endoscopic collection method (endoscopic pancreatic function test). Using SDS-PAGE protein profiling, we investigate (i) precipitation techniques to maximize protein extraction, (ii) auto-digestion of pancreatic fluid following prolonged exposure to a range of temperatures, (iii) effects of multiple freeze-thaw cycles on protein stability, and (iv) the utility of protease inhibitors. Our experiments revealed that TCA precipitation resulted in the most efficient extraction of protein from pancreatic fluid of the eight methods we investigated. In addition, our data reveal that although auto-digestion of proteins is prevalent at 23 and 37 degrees C, incubation on ice significantly slows such degradation. Similarly, when the sample is maintained on ice, proteolysis is minimal during multiple freeze-thaw cycles. We have also determined the addition of protease inhibitors to be assay-dependent. Our optimized sample preparation strategy can be applied to future proteomic analyses of pancreatic fluid.

  7. 7 CFR 160.22 - Collecting samples; issuing certificates.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Section 160.22 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) NAVAL STORES REGULATIONS AND STANDARDS FOR NAVAL STORES Methods of Analysis, Inspection, Sampling and Grading §...

  8. 40 CFR 761.310 - Collecting the sample.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... ACT POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS Sampling Non-Porous Surfaces for Measurement-Based Use, Reuse, and On-Site or Off-Site...

  9. Apollo Lunar Sample Photographs: Digitizing the Moon Rock Collection

    NASA Technical Reports Server (NTRS)

    Lofgren, Gary E.; Todd, Nancy S.; Runco, S. K.; Stefanov, W. L.

    2011-01-01

    The Acquisition and Curation Office at JSC has undertaken a 4-year data restoration project effort for the lunar science community funded by the LASER program (Lunar Advanced Science and Exploration Research) to digitize photographs of the Apollo lunar rock samples and create high resolution digital images. These sample photographs are not easily accessible outside of JSC, and currently exist only on degradable film in the Curation Data Storage Facility

  10. 40 CFR 761.283 - Determination of the number of samples to collect and sample collection locations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... established in paragraph (b)(1)(i) of this section by moving the origin one meter in the direction of magnetic north and one meter in the direction east of magnetic north. (2) Mark out a series of sampling points 1.5 meters apart oriented to the grid axes. The sampling points shall proceed in every direction...

  11. 40 CFR 761.283 - Determination of the number of samples to collect and sample collection locations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... established in paragraph (b)(1)(i) of this section by moving the origin one meter in the direction of magnetic north and one meter in the direction east of magnetic north. (2) Mark out a series of sampling points 1.5 meters apart oriented to the grid axes. The sampling points shall proceed in every direction...

  12. 40 CFR 761.283 - Determination of the number of samples to collect and sample collection locations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... established in paragraph (b)(1)(i) of this section by moving the origin one meter in the direction of magnetic north and one meter in the direction east of magnetic north. (2) Mark out a series of sampling points 1.5 meters apart oriented to the grid axes. The sampling points shall proceed in every direction...

  13. 40 CFR 761.283 - Determination of the number of samples to collect and sample collection locations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... established in paragraph (b)(1)(i) of this section by moving the origin one meter in the direction of magnetic north and one meter in the direction east of magnetic north. (2) Mark out a series of sampling points 1.5 meters apart oriented to the grid axes. The sampling points shall proceed in every direction...

  14. 40 CFR 761.283 - Determination of the number of samples to collect and sample collection locations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... established in paragraph (b)(1)(i) of this section by moving the origin one meter in the direction of magnetic north and one meter in the direction east of magnetic north. (2) Mark out a series of sampling points 1.5 meters apart oriented to the grid axes. The sampling points shall proceed in every direction...

  15. Curating NASA's Past, Present, and Future Extraterrestrial Sample Collections

    NASA Technical Reports Server (NTRS)

    McCubbin, F. M.; Allton, J. H.; Evans, C. A.; Fries, M. D.; Nakamura-Messenger, K.; Righter, K.; Zeigler, R. A.; Zolensky, M.; Stansbery, E. K.

    2016-01-01

    The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10E "Curation of Extraterrestrial Materials", JSC is charged with "...curation of all extra-terrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "...documentation, preservation, preparation, and distribution of samples for research, education, and public outreach." Here we describe some of the past, present, and future activities of the NASA Curation Office.

  16. Methodological Issues of Sample Collection and Analysis of Exhaled Breath

    EPA Science Inventory

    Recommended standardized procedures have been developed for measurement of exhaled lower respiratory nitric oxide (NO) and nasal NO. It would be desirable to develop similar guidelines for the sampling of exhaled breath related to other compounds. For such systemic volatile o...

  17. Technical Evaluation of Sample-Processing, Collection, and Preservation Methods

    DTIC Science & Technology

    2014-07-01

    policy document entitled The National Strategy for Biosurveillance was released (White House, July 2012) as part of the National Security Strategy...concept of leveraging existing capabilities to “scan and discern the environment,” which implies the use of current technical biosurveillance ...testing of existing sample-processing technologies are expected to enable in silico evaluations of biosurveillance methodologies, equipment, and

  18. Spectroscopic Characterization of Dust-Fall Samples Collected from Greater Cairo, Egypt.

    PubMed

    Shaltout, Abdallah A; Allam, Mousa A; Mostafa, Nasser Y; Heiba, Zein K

    2016-04-01

    This work aimed to characterize dust-fall samples collected from street's trees in Greater Cairo (GC), Egypt, and its surroundings by different spectroscopic techniques, namely; X-ray diffraction (XRD), attenuated total-reflection Fourier transform infrared (ATR-FTIR), particle-size analyzer, and scanning electron microscopy (SEM) combined with energy dispersive X-ray measurements. Samples were collected from 19 different locations inside and outside of GC. Quantitative phase analysis of the dust-fall samples was performed using the Rietveld method. Results showed that the most frequently observed phases in the dust-fall samples were calcite (CaCO3), dolomite (CaMg(CO3)2), gypsum (CaSO4·2H2O), and quartz (SiO2) with average concentrations of 39 ± 16, 8 ± 7, 22 ± 13, and 33 ± 14 wt%, respectively. The occurrence of these constituents referred to a combination of different anthropogenic and natural sources. The ATR-FTIR results are in good agreements with XRD data of the different observed phases. Based on the SEM and particle-size measurements, quantitative determination of the particle-size distribution was described. It was found that not only the large-sized particles are deposited but also the small-sized ones (PM10 and PM2.5). In addition, the particle size of the collected dust-fall samples varied from 0.1 to 200 µm with an average particle size of 17.36 µm; however, the particle size ranged from 2.5 to 40 µm predominated in all of the dust-fall samples.

  19. Characterization Data Package for Containerized Sludge Samples Collected from Engineered Container SCS-CON-210

    SciTech Connect

    Fountain, Matthew S.; Fiskum, Sandra K.; Baldwin, David L.; Daniel, Richard C.; Bos, Stanley J.; Burns, Carolyn A.; Carlson, Clark D.; Coffey, Deborah S.; Delegard, Calvin H.; Edwards, Matthew K.; Greenwood, Lawrence R.; Neiner, Doinita; Oliver, Brian M.; Pool, Karl N.; Schmidt, Andrew J.; Shimskey, Rick W.; Sinkov, Sergey I.; Snow, Lanee A.; Soderquist, Chuck Z.; Thompson, Christopher J.; Trang-Le, Truc LT; Urie, Michael W.

    2013-09-10

    This data package contains the K Basin sludge characterization results obtained by Pacific Northwest National Laboratory during processing and analysis of four sludge core samples collected from Engineered Container SCS-CON-210 in 2010 as requested by CH2M Hill Plateau Remediation Company. Sample processing requirements, analytes of interest, detection limits, and quality control sample requirements are defined in the KBC-33786, Rev. 2. The core processing scope included reconstitution of a sludge core sample distributed among four to six 4-L polypropylene bottles into a single container. The reconstituted core sample was then mixed and subsampled to support a variety of characterization activities. Additional core sludge subsamples were combined to prepare a container composite. The container composite was fractionated by wet sieving through a 2,000 micron mesh and a 500-micron mesh sieve. Each sieve fraction was sampled to support a suite of analyses. The core composite analysis scope included density determination, radioisotope analysis, and metals analysis, including the Waste Isolation Pilot Plant Hazardous Waste Facility Permit metals (with the exception of mercury). The container composite analysis included most of the core composite analysis scope plus particle size distribution, particle density, rheology, and crystalline phase identification. A summary of the received samples, core sample reconstitution and subsampling activities, container composite preparation and subsampling activities, physical properties, and analytical results are presented. Supporting data and documentation are provided in the appendices. There were no cases of sample or data loss and all of the available samples and data are reported as required by the Quality Assurance Project Plan/Sampling and Analysis Plan.

  20. Inherent variability in lead and copper collected during standardized sampling.

    PubMed

    Masters, Sheldon; Parks, Jeffrey; Atassi, Amrou; Edwards, Marc A

    2016-03-01

    Variability in the concentration of lead and copper sampled at consumers' taps poses challenges to assessing consumer health threats and the effectiveness of corrosion control. To examine the minimum variability that is practically achievable, standardized rigs with three lead and copper containing plumbing materials (leaded brass, copper tube with lead solder, and a lead copper connection) were deployed at five utilities and sampled with regimented protocols. Variability represented by relative standard deviation (RSD) in lead release was high in all cases. The brass had the lowest variability in lead release (RSD = 31 %) followed by copper-solder (RSD = 49%) and lead-copper (RSD = 80%). This high inherent variability is due to semi-random detachment of particulate lead to water, and represents a modern reality of water lead problems that should be explicitly acknowledged and considered in all aspects of exposure, public education, and monitoring.

  1. Extravehicular Activity Asteroid Exploration and Sample Collection Capability

    NASA Technical Reports Server (NTRS)

    Sipila, Stephanie A.; Scoville, Zebulon C.; Bowie, Jonathan T.; Buffington, Jesse A.

    2014-01-01

    One of the challenging primary objectives associated with NASA's Asteroid Redirect Crewed Mission (ARCM) is to demonstrate deep space Extravehicular Activity (EVA) and tools and to obtain asteroid samples to return to Earth for further study. Prior Shuttle and International Space Station (ISS) spacewalks have benefited from engineered EVA interfaces which have been designed and manufactured on Earth. Rigid structurally mounted handrails, and tools with customized interfaces and restraints optimize EVA performance. For ARCM, EVA complexity increases due to the uncertainty of the asteroid properties. The variability of rock size, shape and composition, as well as behavior of the asteroid capture mechanism will complicate EVA translation, tool restraint, and body stabilization. The unknown asteroid hardness and brittleness will complicate tool use. The rock surface will introduce added safety concerns for cut gloves and debris control. Feasible solutions to meet ARCM EVA objectives were identified using experience gained during Apollo, Shuttle, and ISS EVAs, terrestrial mountaineering practices, NASA Extreme Environment Mission Operations (NEEMO) 16 mission, and during Neutral Buoyancy Laboratory testing in the Modified Advanced Crew Escape Suit (MACES) suit. This paper will summarize the overall operational concepts for conducting EVAs for the ARCM mission including translation paths and body restraint methods, potential tools used to extract the samples, design implications for the Asteroid Redirect Vehicle (ARV) for EVA, and the results of early development testing of potential EVA tasks.

  2. 31. VIEW FROM SOUTHWEST TO CORNER WHERE SAMPLING/CRUSHING ADDITIONS ABUT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. VIEW FROM SOUTHWEST TO CORNER WHERE SAMPLING/CRUSHING ADDITIONS ABUT CRUSHED OXIDIZED ORE BIN. INTACT BARREN SOLUTION TANK VISIBLE IN FRONT OF CRUSHED ORE BIN. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD

  3. Comparison of self-collected vaginal, vulvar and urine samples with physician-collected cervical samples for human papillomavirus testing to detect high-grade squamous intraepithelial lesions

    PubMed Central

    Sellors, John W.; Lorincz, Attila T.; Mahony, James B.; Mielzynska, Iwona; Lytwyn, Alice; Roth, Paula; Howard, Michelle; Chong, Sylvia; Daya, Dean; Chapman, William; Chernesky, Max

    2000-01-01

    Background Certain types of human papillomavirus (HPV) in cervical samples are strongly associated with squamous intraepithelial lesions (SIL) and invasive cervical carcinoma. We determined and compared the test characteristics of testing for HPV with samples obtained by patients and with samples obtained by their physicians. Methods In a consecutive series of women referred to a colposcopy clinic at a teaching hospital because of abnormalities on cervical cytologic screening, 200 agreed to collect vulvar, vaginal and urine samples for HPV testing. The physician then collected cervical samples for HPV testing, and colposcopy, with biopsy as indicated, was performed. Presence of HPV was evaluated using the hybrid capture II assay (Digene Corp., Silver Spring, Md.) with a probe cocktail for 13 carcinogenic types. Cervical specimens were also tested for HPV by polymerase chain reaction and hybridization with type-specific probes. Cervical smears for cytologic examination were obtained from all women. Results High-grade lesions (high-grade squamous intraepithelial lesions [HSIL], equivalent to cervical intraepithelial neoplasia [CIN] grade 2 or 3, and adenocarcinoma) were found in 58 (29.0%) of the 200 women. Carcinogenic types of HPV were detected in the self-collected vaginal samples of 50 (86.2%) of these 58 women, in the self-collected vulvar samples of 36 (62.1%) and in the self-collected urine samples of 26 (44.8%). Carcinogenic types of HPV were detected in the cervical samples collected by physicians for 57 (98.3%) of these 58 women. The remaining 142 women (71.0%) had normal findings or low-grade squamous intraepithelial lesions (LSIL, CIN grade 1). Test results were negative or noncarcinogenic types of HPV were detected in the self-collected vaginal samples of 76 (53.5%) of these 142 women, in the self-collected vulvar samples of 89 (62.7%) and in the self-collected urine samples of 99 (69.7%). The sensitivity for self-collected samples ranged from 44.8% to

  4. Studies of levels of biogenic amines in meat samples in relation to the content of additives.

    PubMed

    Jastrzębska, Aneta; Kowalska, Sylwia; Szłyk, Edward

    2016-01-01

    The impact of meat additives on the concentration of biogenic amines and the quality of meat was studied. Fresh white and red meat samples were fortified with the following food additives: citric and lactic acids, disodium diphosphate, sodium nitrite, sodium metabisulphite, potassium sorbate, sodium chloride, ascorbic acid, α-tocopherol, propyl 3,4,5-trihydroxybenzoate (propyl gallate) and butylated hydroxyanisole. The content of spermine, spermidine, putrescine, cadaverine, histamine, tyramine, tryptamine and 2-phenylethylamine was determined by capillary isotachophoretic methods in meat samples (fresh and fortified) during four days of storage at 4°C. The results were applied to estimate the impact of the tested additives on the formation of biogenic amines in white and red meat. For all tested meats, sodium nitrite, sodium chloride and disodium diphosphate showed the best inhibition. However, cadaverine and putrescine were characterised by the biggest changes in concentration during the storage time of all the additives. Based on the presented data for the content of biogenic amines in meat samples analysed as a function of storage time and additives, we suggest that cadaverine and putrescine have a significant impact on meat quality.

  5. Collection and analysis of NASA clean room air samples

    NASA Technical Reports Server (NTRS)

    Sheldon, L. S.; Keever, J.

    1985-01-01

    The environment of the HALOE assembly clean room at NASA Langley Research Center is analyzed to determine the background levels of airborne organic compounds. Sampling is accomplished by pumping the clean room air through absorbing cartridges. For volatile organics, cartridges are thermally desorbed and then analyzed by gas chromatography and mass spectrometry, compounds are identified by searching the EPA/NIH data base using an interactive operator INCOS computer search algorithm. For semivolatile organics, cartridges are solvent entracted and concentrated extracts are analyzed by gas chromatography-electron capture detection, compound identification is made by matching gas chromatogram retention times with known standards. The detection limits for the semivolatile organics are; 0.89 ng cu m for dioctylphlhalate (DOP) and 1.6 ng cu m for polychlorinated biphenyls (PCB). The detection limit for volatile organics ranges from 1 to 50 parts per trillion. Only trace quantities of organics are detected, the DOP levels do not exceed 2.5 ng cu m and the PCB levels do not exceed 454 ng cu m.

  6. Study design in qualitative research--2: Sampling and data collection strategies.

    PubMed

    Devers, K J; Frankel, R M

    2000-01-01

    In two prior papers in our series on qualitative research [Frankel & Devers (2000a, 2000b) Qualitative research: a consumer's guide, Education for Health, 13, 113-123; Frankel & Devers (2000) Study design in qualitative research-1: developing research questions and assessing research needs, Education for Health, 13, 251-261], we examine two critical issues in qualitative research design: sampling, including identifying and negotiating access to research sites and subjects, and data collection and management. We describe these two key steps in the qualitative research design process, discuss challenges that often emerge when pursuing these steps, and provide guidelines for addressing them. Qualitative research most often uses "purposive," rather than random, sampling strategies. A good understanding of these sampling strategies and why they are used is central to designing a credible qualitative study. In addition, given the real-world context in which most qualitative research is carried out, identifying and negotiating access to research sites and subjects are critical parts of the process. We also provide suggestions for developing and maintaining productive and mutually satisfying research relationships with sites and subjects. Finally, data collection and management are often neglected subjects in qualitative research. We offer practical advice on how to collect and manage qualitative data, including factors to consider when deciding how structured the data collection process should be, the pros and cons of audio- and/or videotaping compared with note-taking, and tips for writing up field notes and document management. A forthcoming, final paper in the series will focus on qualitative data analysis and the publication of qualitative research results.

  7. RoboHound:developing sample collection and preconcentration hardware for a remote trace explosives detection system.

    SciTech Connect

    Peterson, David J.; Denning, David J.; Hobart, Clinton G.; Lenz, Michael C.; Anderson, Robert J.; Carlson, Dennis L.; Hunter, John Anthony; Gladwell, T. Scott; Mitchell, Mary-Anne; Hannum, David W.; Baumann, Mark J.

    2005-09-01

    The RoboHound{trademark} Project was a three-year, multiphase project at Sandia National Laboratories to build and refine a working prototype trace explosive detection system as a tool for a commercial robot. The RoboHound system was envisioned to be a tool for emergency responders to test suspicious items (i.e., packages or vehicles) for explosives while maintaining a safe distance. The project investigated combining Sandia's expertise in trace explosives detection with a wheeled robotic platform that could be programmed to interrogate suspicious items remotely for the presence of explosives. All of the RoboHound field tests were successful, especially with regards to the ability to collect and detect trace samples of RDX. The project has gone from remote sampling with human intervention to a fully automatic system that requires no human intervention until the robot returns from a sortie. A proposal is being made for additional work leading towards commercialization.

  8. 40 CFR 761.286 - Sample size and procedure for collecting a sample.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) TOXIC SUBSTANCES CONTROL ACT POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS Sampling To Verify Completion of Self-Implementing Cleanup...

  9. Odour and flavour thresholds of gasoline additives (MTBE, ETBE and TAME) and their occurrence in Dutch drinking water collection areas.

    PubMed

    van Wezel, Annemarie; Puijker, Leo; Vink, Cees; Versteegh, Ans; de Voogt, Pim

    2009-07-01

    The use of ETBE (ethyl-tert-butylether) as gasoline additive has recently grown rapidly. Contamination of aquatic systems is well documented for MTBE (methyl-tert-butylether), but less for other gasoline additives. Due to their mobility they may easily reach drinking water collection areas. Odour and flavour thresholds of MTBE are known to be low, but for ETBE and TAME (methyl-tert-amylether) hardly information is available. The objective here is to determine these thresholds for MTBE, ETBE and TAME, and relate these to concentrations monitored in thousands of samples from Dutch drinking water collection areas. For ETBE odour and flavour thresholds are low with 1-2microgL(-1), for MTBE and TAME they range from 7 to 16microg L(-1). In most groundwater collection areas MTBE concentrations are below 0.1microg L(-1). In phreatic groundwaters in sandy soils not covered by a protective soil layer, occasionally MTBE occurs at higher concentrations. For surface water collection areas a minority of the locations is free of MTBE. For river bank and dune infiltrates, at a few locations the odour and flavour threshold is exceeded. For ETBE fewer monitoring data are available. ETBE was found in 2 out of 37 groundwater collection areas, in concentrations below 1microgL(-1). In the surface water collection areas monitored ETBE was found in concentrations near to the odour and flavour thresholds. The low odour and flavour thresholds combined with the high mobility and persistence of these compounds, their high production volumes and their increased use may yield problems with future production of drinking water.

  10. Attic dust and human blood samples collected near a former wood treatment facility.

    PubMed

    Hensley, A R; Scott, A; Rosenfeld, P E; Clark, J J J

    2007-10-01

    A wood treatment facility operating in southern Alabama released dioxins and other hazardous substances into the surrounding community over a period of approximately 35 years. The facility used a variety of chemical insecticides including pentachlorophenol (PCP), chromated copper arsenate (CCA), and creosote (which contains polycyclic aromatic hydrocarbons (PAHs)) to treat wood. The health risks associated with the released contaminants are numerous and significant. To evaluate the historic exposure to the contaminants from the facility, blood samples and health surveys were collected from 21 current and past residents of the adjacent, isolated community and analyzed for concentrations of polychlorinated dibenzo-p-dioxins (dioxins) and polychlorinated dibenzofurans (furans). In addition, attic dust sampling was performed in 11 buildings located within a 1-mile radius of the former wood treatment facility. The average total dioxin toxic equivalent (TEQ) concentration in the residents' blood samples was 36.6 pg/g lipids. In the attic dust, the average total dioxin TEQ concentration, benzo[a]pyrene (PAH) TEQ concentration, and arsenic concentration were 145 ng/kg, 0.98 and 29.8 mg/kg, respectively. The concentrations of dioxins measured in the blood samples exceed the 90th percentile total dioxin levels found in the general US adult population. Concentrations of dioxin, arsenic, and PAHs found in the attic samples exceeded the US Environmental Protection Agency (USEPA) Region 4 soil exposure cancer risk preliminary remediation goal (PRG) values. These findings indicate a very significant potential for related health effects in these communities.

  11. Collecting cometary soil samples? Development of the ROSETTA sample acquisition system

    NASA Technical Reports Server (NTRS)

    Coste, P. A.; Fenzi, M.; Eiden, Michael

    1993-01-01

    In the reference scenario of the ROSETTA CNRS mission, the Sample Acquisition System is mounted on the Comet Lander. Its tasks are to acquire three kinds of cometary samples and to transfer them to the Earth Return Capsule. Operations are to be performed in vacuum and microgravity, on a probably rough and dusty surface, in a largely unknown material, at temperatures in the order of 100 K. The concept and operation of the Sample Acquisition System are presented. The design of the prototype corer and surface sampling tool, and of the equipment for testing them at cryogenic temperatures in ambient conditions and in vacuum in various materials representing cometary soil, are described. Results of recent preliminary tests performed in low temperature thermal vacuum in a cometary analog ice-dust mixture are provided.

  12. 40 CFR 761.286 - Sample size and procedure for collecting a sample.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) TOXIC SUBSTANCES CONTROL ACT POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING... On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6... PCB remediation waste or porous surfaces, collect at least 20 milliliters of waste, or a portion...

  13. 40 CFR 761.286 - Sample size and procedure for collecting a sample.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) TOXIC SUBSTANCES CONTROL ACT POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING... On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6... PCB remediation waste or porous surfaces, collect at least 20 milliliters of waste, or a portion...

  14. 40 CFR 761.286 - Sample size and procedure for collecting a sample.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) TOXIC SUBSTANCES CONTROL ACT POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING... On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6... PCB remediation waste or porous surfaces, collect at least 20 milliliters of waste, or a portion...

  15. Sample data processing in an additive and reproducible taxonomic workflow by using character data persistently linked to preserved individual specimens

    PubMed Central

    Kilian, Norbert; Henning, Tilo; Plitzner, Patrick; Müller, Andreas; Güntsch, Anton; Stöver, Ben C.; Müller, Kai F.; Berendsohn, Walter G.; Borsch, Thomas

    2015-01-01

    We present the model and implementation of a workflow that blazes a trail in systematic biology for the re-usability of character data (data on any kind of characters of pheno- and genotypes of organisms) and their additivity from specimen to taxon level. We take into account that any taxon characterization is based on a limited set of sampled individuals and characters, and that consequently any new individual and any new character may affect the recognition of biological entities and/or the subsequent delimitation and characterization of a taxon. Taxon concepts thus frequently change during the knowledge generation process in systematic biology. Structured character data are therefore not only needed for the knowledge generation process but also for easily adapting characterizations of taxa. We aim to facilitate the construction and reproducibility of taxon characterizations from structured character data of changing sample sets by establishing a stable and unambiguous association between each sampled individual and the data processed from it. Our workflow implementation uses the European Distributed Institute of Taxonomy Platform, a comprehensive taxonomic data management and publication environment to: (i) establish a reproducible connection between sampled individuals and all samples derived from them; (ii) stably link sample-based character data with the metadata of the respective samples; (iii) record and store structured specimen-based character data in formats allowing data exchange; (iv) reversibly assign sample metadata and character datasets to taxa in an editable classification and display them and (v) organize data exchange via standard exchange formats and enable the link between the character datasets and samples in research collections, ensuring high visibility and instant re-usability of the data. The workflow implemented will contribute to organizing the interface between phylogenetic analysis and revisionary taxonomic or monographic work

  16. The use of Vacutainer tubes for collection of soil samples for helium analysis

    USGS Publications Warehouse

    Hinkle, Margaret E.; Kilburn, James E.

    1979-01-01

    Measurements of the helium concentration of soil samples collected and stored in Vacutainer-brand evacuated glass tubes show that Vacutainers are reliable containers for soil collection. Within the limits of reproducibility, helium content of soils appears to be independent of variations in soil temperature, barometric pressure, and quantity of soil moisture present in the sample.

  17. Adaptive Sampling-Based Information Collection for Wireless Body Area Networks.

    PubMed

    Xu, Xiaobin; Zhao, Fang; Wang, Wendong; Tian, Hui

    2016-08-31

    To collect important health information, WBAN applications typically sense data at a high frequency. However, limited by the quality of wireless link, the uploading of sensed data has an upper frequency. To reduce upload frequency, most of the existing WBAN data collection approaches collect data with a tolerable error. These approaches can guarantee precision of the collected data, but they are not able to ensure that the upload frequency is within the upper frequency. Some traditional sampling based approaches can control upload frequency directly, however, they usually have a high loss of information. Since the core task of WBAN applications is to collect health information, this paper aims to collect optimized information under the limitation of upload frequency. The importance of sensed data is defined according to information theory for the first time. Information-aware adaptive sampling is proposed to collect uniformly distributed data. Then we propose Adaptive Sampling-based Information Collection (ASIC) which consists of two algorithms. An adaptive sampling probability algorithm is proposed to compute sampling probabilities of different sensed values. A multiple uniform sampling algorithm provides uniform samplings for values in different intervals. Experiments based on a real dataset show that the proposed approach has higher performance in terms of data coverage and information quantity. The parameter analysis shows the optimized parameter settings and the discussion shows the underlying reason of high performance in the proposed approach.

  18. Adaptive Sampling-Based Information Collection for Wireless Body Area Networks

    PubMed Central

    Xu, Xiaobin; Zhao, Fang; Wang, Wendong; Tian, Hui

    2016-01-01

    To collect important health information, WBAN applications typically sense data at a high frequency. However, limited by the quality of wireless link, the uploading of sensed data has an upper frequency. To reduce upload frequency, most of the existing WBAN data collection approaches collect data with a tolerable error. These approaches can guarantee precision of the collected data, but they are not able to ensure that the upload frequency is within the upper frequency. Some traditional sampling based approaches can control upload frequency directly, however, they usually have a high loss of information. Since the core task of WBAN applications is to collect health information, this paper aims to collect optimized information under the limitation of upload frequency. The importance of sensed data is defined according to information theory for the first time. Information-aware adaptive sampling is proposed to collect uniformly distributed data. Then we propose Adaptive Sampling-based Information Collection (ASIC) which consists of two algorithms. An adaptive sampling probability algorithm is proposed to compute sampling probabilities of different sensed values. A multiple uniform sampling algorithm provides uniform samplings for values in different intervals. Experiments based on a real dataset show that the proposed approach has higher performance in terms of data coverage and information quantity. The parameter analysis shows the optimized parameter settings and the discussion shows the underlying reason of high performance in the proposed approach. PMID:27589758

  19. Metabolite and Lipid Profiling of Biobank Plasma Samples Collected Prior to Onset of Rheumatoid Arthritis

    PubMed Central

    Surowiec, Izabella; Ärlestig, Lisbeth

    2016-01-01

    Objective The early diagnosis of rheumatoid arthritis (RA) is desirable to install treatment to prevent disease progression and joint destruction. Autoantibodies and immunological markers pre-date the onset of symptoms by years albeit not all patients will present these factors, even at disease onset. Additional biomarkers would be of high value to improve early diagnosis and understanding of the process, leading to disease development. Methods Plasma samples donated before the onset of RA were identified in the Biobank of Northern Sweden, a collection within national health survey programs. Thirty samples from pre-symptomatic individuals and nineteen from controls were subjected to liquid chromatography-mass spectrometry (LCMS) metabolite and lipid profiling. Lipid and metabolite profiles discriminating samples from pre-symptomatic individuals from controls were identified after univariate and multivariate OPLS-DA based analyses. Results The OPLS-DA models including pre-symptomatic individuals and controls identified profiles differentiating between the groups that was characterized by lower levels of acyl-carnitines and fatty acids, with higher levels of lysophospatidylcholines (LPCs) and metabolites from tryptophan metabolism in pre-symptomatic individuals compared with controls. Lipid profiling showed that the majority of phospholipids and sphingomyelins were at higher levels in pre-symptomatic individuals in comparison with controls. Conclusions Our LCMS based approach demonstrated that there are changes in small molecule and lipid profiles detectable in plasma samples collected from the pre-symptomatic individuals who subsequently developed RA, which point to an up-regulation of levels of lysophospatidylcholines, and of tryptophan metabolism, perturbation of fatty acid beta-oxidation and increased oxidative stress in pre-symptomatic individuals’ years before onset of symptoms. PMID:27755546

  20. Sampling strategies and post-processing methods for increasing the time resolution of organic aerosol measurements requiring long sample-collection times

    NASA Astrophysics Data System (ADS)

    Modini, Rob L.; Takahama, Satoshi

    2016-07-01

    The composition and properties of atmospheric organic aerosols (OAs) change on timescales of minutes to hours. However, some important OA characterization techniques typically require greater than a few hours of sample-collection time (e.g., Fourier transform infrared (FTIR) spectroscopy). In this study we have performed numerical modeling to investigate and compare sample-collection strategies and post-processing methods for increasing the time resolution of OA measurements requiring long sample-collection times. Specifically, we modeled the measurement of hydrocarbon-like OA (HOA) and oxygenated OA (OOA) concentrations at a polluted urban site in Mexico City, and investigated how to construct hourly resolved time series from samples collected for 4, 6, and 8 h. We modeled two sampling strategies - sequential and staggered sampling - and a range of post-processing methods including interpolation and deconvolution. The results indicated that relative to the more sophisticated and costly staggered sampling methods, linear interpolation between sequential measurements is a surprisingly effective method for increasing time resolution. Additional error can be added to a time series constructed in this manner if a suboptimal sequential sampling schedule is chosen. Staggering measurements is one way to avoid this effect. There is little to be gained from deconvolving staggered measurements, except at very low values of random measurement error (< 5 %). Assuming 20 % random measurement error, one can expect average recovery errors of 1.33-2.81 µg m-3 when using 4-8 h-long sequential and staggered samples to measure time series of concentration values ranging from 0.13-29.16 µg m-3. For 4 h samples, 19-47 % of this total error can be attributed to the process of increasing time resolution alone, depending on the method used, meaning that measurement precision would only be improved by 0.30-0.75 µg m-3 if samples could be collected over 1 h instead of 4 h. Devising a

  1. Collecting Samples in Gale Crater, Mars; an Overview of the Mars Science Laboratory Sample Acquisition, Sample Processing and Handling System

    NASA Astrophysics Data System (ADS)

    Anderson, R. C.; Jandura, L.; Okon, A. B.; Sunshine, D.; Roumeliotis, C.; Beegle, L. W.; Hurowitz, J.; Kennedy, B.; Limonadi, D.; McCloskey, S.; Robinson, M.; Seybold, C.; Brown, K.

    2012-09-01

    The Mars Science Laboratory Mission (MSL), scheduled to land on Mars in the summer of 2012, consists of a rover and a scientific payload designed to identify and assess the habitability, geological, and environmental histories of Gale crater. Unraveling the geologic history of the region and providing an assessment of present and past habitability requires an evaluation of the physical and chemical characteristics of the landing site; this includes providing an in-depth examination of the chemical and physical properties of Martian regolith and rocks. The MSL Sample Acquisition, Processing, and Handling (SA/SPaH) subsystem will be the first in-situ system designed to acquire interior rock and soil samples from Martian surface materials. These samples are processed and separated into fine particles and distributed to two onboard analytical science instruments SAM (Sample Analysis at Mars Instrument Suite) and CheMin (Chemistry and Mineralogy) or to a sample analysis tray for visual inspection. The SA/SPaH subsystem is also responsible for the placement of the two contact instruments, Alpha Particle X-Ray Spectrometer (APXS), and the Mars Hand Lens Imager (MAHLI), on rock and soil targets. Finally, there is a Dust Removal Tool (DRT) to remove dust particles from rock surfaces for subsequent analysis by the contact and or mast mounted instruments (e.g. Mast Cameras (MastCam) and the Chemistry and Micro-Imaging instruments (ChemCam)).

  2. On the asymptotic improvement of supervised learning by utilizing additional unlabeled samples - Normal mixture density case

    NASA Technical Reports Server (NTRS)

    Shahshahani, Behzad M.; Landgrebe, David A.

    1992-01-01

    The effect of additional unlabeled samples in improving the supervised learning process is studied in this paper. Three learning processes. supervised, unsupervised, and combined supervised-unsupervised, are compared by studying the asymptotic behavior of the estimates obtained under each process. Upper and lower bounds on the asymptotic covariance matrices are derived. It is shown that under a normal mixture density assumption for the probability density function of the feature space, the combined supervised-unsupervised learning is always superior to the supervised learning in achieving better estimates. Experimental results are provided to verify the theoretical concepts.

  3. Multiplex short tandem repeat amplification of low template DNA samples with the addition of proofreading enzymes.

    PubMed

    Davis, Carey P; Chelland, Lynzee A; Pavlova, Victoria R; Illescas, María J; Brown, Kelly L; Cruz, Tracey Dawson

    2011-05-01

    With <100 pg of template DNA, routine short tandem repeat (STR) analysis often fails, resulting in no or partial profiles and increased stochastic effects. To overcome this, some have investigated preamplification methods that include the addition of proofreading enzymes to the PCR cocktail. This project sought to determine whether adding proofreading polymerases directly in the STR amplification mixture would improve the reaction when little template DNA is available. Platinum Taq High Fidelity and GeneAmp High Fidelity were tested in Profiler Plus™ STR reactions alone and in combination with AmpliTaq(®) Gold. All reactions included the additional step of a post-PCR purification step. With both pristine low template DNA and casework samples, the addition of these polymerases resulted in comparable or no improvement in the STR amplification signal. Further, stochastic effects and artifacts were observed equally across all enzyme conditions. Based on these studies, the addition of these proofreading enzymes to a multiplex STR amplification is not recommended for low template DNA work.

  4. Prototype Device for Computerized Blood Sampling and Data Collection in Freely Moving Swine

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Collecting biofluid samples or physiological and behavioral data from animals presents challenges from excessive human intervention, and the stress of manual sampling. Our objective was to construct a device capable of protecting external leads and tubing used to facilitate automated sampling, dosin...

  5. Chemical fingerprinting of petroleum biomarkers in Deepwater Horizon oil spill samples collected from Alabama shoreline.

    PubMed

    Mulabagal, V; Yin, F; John, G F; Hayworth, J S; Clement, T P

    2013-05-15

    We compare the chromatographic signatures of petroleum biomarkers in Deepwater Horizon (DH) source oil, three other reference crude oils, DH emulsified mousse that arrived on Alabama's shoreline in June 2010, and seven tar balls collected from Alabama beaches from 2011 to 2012. Characteristic hopane and sterane fingerprints show that all the tar ball samples originated from DH oil. In addition, the diagnostic ratios of various hopanes indicate an excellent match. Quantitation data for C₃₀αβ-hopane concentration levels show that most of the weathering observed in DH-related tar balls found on Alabama's beaches is likely the result of natural evaporation and dissolution that occurred during transport across the Gulf of Mexico prior to beach deposition. Based on the physical and biomarker characterization data presented in this study we conclude that virtually all fragile, sticky, brownish tar balls currently found on Alabama shoreline originated from the DH oil spill.

  6. Clinically relevant differences in prothrombin time and INR values related to blood sample collection in plastic vs glass tubes.

    PubMed

    Fiebig, Eberhard W; Etzell, Joan E; Ng, Valerie L

    2005-12-01

    We compared prothrombin times (PTs) and international normalized ratios (INRs) for blood samples drawn into plastic vs glass collection tubes. We collected 60 venous blood samples into 4.5-mL glass and 2 plastic tubes (2.7 and 3.5 mL). An additional 153 samples, including 63 from warfarin-anticoagulated patients, were collected only in glass and 2.7-mL plastic tubes. The PTs and INRs were determined following routine laboratory procedures. A subset of 35 frozen aliquot samples was analyzed with a different instrument-reagent combination. The PTs and INRs for samples in plastic tubes were significantly lower than for samples in glass tubes. The mean INR differences increased with INR magnitude from approximately -0.1 (INR, 1.5) to -0.7 (INR, 4.5). Of the plastic tube INRs, 50% were more than 10% lower than INRs from samples collected in glass tubes. Therapeutic monitoring based on plastic-tube INRs could result in higher doses of warfarin.

  7. A method to determine collection efficiency of particles by swipe sampling

    NASA Astrophysics Data System (ADS)

    Verkouteren, J. R.; Coleman, J. L.; Fletcher, R. A.; Smith, W. J.; Klouda, G. A.; Gillen, G.

    2008-11-01

    A methodology was developed to evaluate particle collection efficiencies from swipe sampling of trace residues. Swipe sampling is used for many applications where trace residues must be collected, including the evaluation of radioactive particle contamination and the analysis of explosives and contraband at screening checkpoints using ion mobility spectrometry (IMS). Collection efficiencies were evaluated for micrometer-sized polystyrene latex (PSL) spheres with respect to the particle size and mode of deposition, collection trap, surface type and swiping force. Test surfaces containing particles were prepared under controlled conditions and swiped with a reproducible technique that allows for the evaluation of frictional forces. Collection efficiencies were determined by optical imaging and particle counting. Of the two IMS collection traps studied, the polytetrafluoroethylene (PTFE) trap has significantly lower collection efficiencies. This is likely to be due to a combination of texture and composition. The larger (42 µm diameter) particles are collected more efficiently than the smaller (9 µm diameter) particles. Particles in a matrix similar to latent fingerprints are collected more efficiently than dry particles. Applying greater force during swiping does not greatly improve collection efficiencies. This fact, coupled with the observation that many particles are detached but not collected, implies that improvements in collection efficiency are dependent on improvements in adhesion of the particles to the collection surface, rather than larger forces to detach the particles.

  8. Clinical forensic sample collection techniques following consensual intercourse in volunteers - cervical canal brush compared to conventional swabs.

    PubMed

    Joki-Erkkilä, Minna; Tuomisto, Sari; Seppänen, Mervi; Huhtala, Heini; Ahola, Arja; Rainio, Juha; Karhunen, Pekka J

    2014-10-01

    The purpose of the research was to evaluate gynecological evidence collection techniques; the benefit of cervical canal brush sample compared to vaginal fornix and cervical swab samples and the time frame for detecting Y-chromosomal material QiAmp DNA Mini Kit(®) and Quantifiler Y Human Male DNA Quantification Kit(®) in adult volunteers following consensual intercourse. Eighty-four adult female volunteers following consensual intercourse were recruited for the study. By combining all sample collecting techniques, 81.0% of the volunteers were Y-DNA positive. Up to 60 h the conventional swab sampling techniques detected more Y-DNA positive samples when compared to the brush technique. However, after 60 h, the cervical canal brush sample technique showed its benefit by detecting 27.3% (6/22) of Y-DNA positive samples, which were Y-DNA negative in both conventional swab sampling techniques. By combining swab and brush techniques, 75% of the volunteers were still Y-DNA positive in 72-144 post-coital hours. The rate of measurable Y-DNA decreased approximately 3% per hour. Despite reported consensual intercourse, 6.8% (3/44) of volunteers were Y-DNA negative within 48 h. Y-DNA was not detected after 144 post-coital hours (6 days). In conclusion, the brush as a forensic evidence collection method may provide additional biological trace evidence from the cervical canal, although the best biological trace evidence collection can be obtained by combining all three sampling techniques. The time frame for gynecological forensic evidence sample collection should be considered to be at least a week if sexual violence is suspected.

  9. Pediatric blood sample collection from a pre-existing peripheral intravenous (PIV) catheter.

    PubMed

    Braniff, Heather; DeCarlo, Ann; Haskamp, Amy Corey; Broome, Marion E

    2014-01-01

    Aiming to minimize pain in a hospitalized child, the purpose of this observational study was to describe characteristics of blood samples collected from pre-existing peripheral intravenous (PIV) catheters in pediatric patients. One hundred and fifty blood samples were reviewed for number of unusable samples requiring a specimen to be re-drawn. Success of the blood draw and prevalence of the loss of the PIV following blood collection was also measured. Findings included one clotted specimen, success rate of 91.3%, and 1.3% of PIVs becoming non-functional after collection. Obtaining blood specimens from a pre-existing PIV should be considered in a pediatric patient.

  10. Statistical inference for the additive hazards model under outcome-dependent sampling.

    PubMed

    Yu, Jichang; Liu, Yanyan; Sandler, Dale P; Zhou, Haibo

    2015-09-01

    Cost-effective study design and proper inference procedures for data from such designs are always of particular interests to study investigators. In this article, we propose a biased sampling scheme, an outcome-dependent sampling (ODS) design for survival data with right censoring under the additive hazards model. We develop a weighted pseudo-score estimator for the regression parameters for the proposed design and derive the asymptotic properties of the proposed estimator. We also provide some suggestions for using the proposed method by evaluating the relative efficiency of the proposed method against simple random sampling design and derive the optimal allocation of the subsamples for the proposed design. Simulation studies show that the proposed ODS design is more powerful than other existing designs and the proposed estimator is more efficient than other estimators. We apply our method to analyze a cancer study conducted at NIEHS, the Cancer Incidence and Mortality of Uranium Miners Study, to study the risk of radon exposure to cancer.

  11. Statistical inference for the additive hazards model under outcome-dependent sampling

    PubMed Central

    Yu, Jichang; Liu, Yanyan; Sandler, Dale P.; Zhou, Haibo

    2015-01-01

    Cost-effective study design and proper inference procedures for data from such designs are always of particular interests to study investigators. In this article, we propose a biased sampling scheme, an outcome-dependent sampling (ODS) design for survival data with right censoring under the additive hazards model. We develop a weighted pseudo-score estimator for the regression parameters for the proposed design and derive the asymptotic properties of the proposed estimator. We also provide some suggestions for using the proposed method by evaluating the relative efficiency of the proposed method against simple random sampling design and derive the optimal allocation of the subsamples for the proposed design. Simulation studies show that the proposed ODS design is more powerful than other existing designs and the proposed estimator is more efficient than other estimators. We apply our method to analyze a cancer study conducted at NIEHS, the Cancer Incidence and Mortality of Uranium Miners Study, to study the risk of radon exposure to cancer. PMID:26379363

  12. A Review of Metal Concentrations Measured in Surface Soil Samples Collected on and Around the Hanford Site

    SciTech Connect

    Fritz, Brad G.

    2009-07-27

    The data used in this report was collected by two separate projects. The Surface Environmental Surveillance Project collected routine samples in 2008 at 41 locations on and around the Hanford Site, and had them analyzed for metals in addition to the normal radiological constituents. In 2004 and 2005, soil samples were collected at 117 locations on the Hanford Reach National Monument (HRNM) in support of the radiological release of that property. In 2008, archived HRNM soil samples were analyzed for metals to supplement the radiological analyses. Concentration results for 30 individual metals were generated by the analytical methods. Selenium and antimony were not measured at detectable concentrations in most of the samples. Mercury was detected in about half of the samples analyzed. All other constituents were measured at detectable concentrations in nearly all samples analyzed. The average concentrations measured in this study were well below the soil cleanup levels for unrestricted land use established by the Model Toxics Control Act (MTCA). In addition to the average concentration being less than the benchmark, the 90th percentile concentration was also lower than the benchmark for the metals included in the MTCA. The results indicate that the measured concentrations of metals in surface soil were within the expected natural range of concentrations.

  13. Mars Rover Sample Return: A sample collection and analysis strategy for exobiology

    NASA Technical Reports Server (NTRS)

    Sims, M. H.; Fischler, M.; Schwartz, D. E.; Rosenthal, Donald A.; Mancinelli, Rocco L.; Nedell, Susan S.; Gamble, E.; Mckay, Christopher P.

    1989-01-01

    For reasons defined elsewhere it is reasonable to search for biological signatures, both chemical and morphological, of extinct life on Mars. Life on Earth requries the presence of liquid water, therefore, it is important to explore sites on Mars where standing bodies of water may have once existed. Outcrops of layered deposits within the Valles Marineris appear to be ancient lake beds. Because the outcrops are well exposed, relatively shallow core samples would be very informative. The most important biological signature to detect would be organics, microfossils, or larger stromato-like structures, although the presence of cherts, carbonates, clays, and shales would be significant. In spite of the limitations of current robotics and pattern recognition, and the limitations of rover power, computation, Earth communication bandwidth, and time delays, a partial scenario was developed to implement such a scientific investigation. The rover instrumentation and the procedures and decisions and IR spectrometer are described in detail. Preliminary results from a collaborative effort are described, which indicate the rover will be able to autonomously detect stratification, and hence will ease the interpretation burden and lead to greater scientific productivity during the rover's lifetime.

  14. A comparison of sampling media for environmental viable fungi collected in a hospital environment.

    PubMed

    Wu, P C; Su, H J; Ho, H M

    2000-03-01

    Quantitative evaluation of fungal exposure is often conducted by analysis of the composition of microbes in air samples and calculation of the concentrations afterward. The collecting medium that favors the growth for most saprophytic fungi is considered to be the ideal choice in most circumstances. Currently, the culture medium most frequently adopted in environmental sampling for airborne fungi is MEA (malt extract agar) recommended by the ACGIH for its suitability for most fungal growth. DG18 (dichloran glycerol-18), developed in 1980, is suggested for growth at lower water activity (a(w)=0.95) specifically and is not as commonly used in general studies. This investigation collected airborne viable fungi using a single stage/N6 Andersen impactor with MEA and DG18 agar plates attached simultaneously to the same set of samplers. The sampling locations were at 17 sites within a central air-conditioned hospital. After incubation and morphological identification, concentrations of airborne fungi and bacteria were expressed as CFU/m(3) (colony forming units/m(3)). There are 405 DG18 plates and 378 plates available for statistical analysis. Results show that the airborne fungal concentrations, shown by geometric mean (GM), are higher from the DG18 plates than from the MEA plates. The total fungal concentrations is 68.6 vs 12.94 CFU/m(3), and for Aspergillus spp., the concentration is 1.58 vs 0.72 CFU/m(3); for Penicillium spp., 3.37 vs 0.71; and for yeast, 5.09 vs 0.49 CFU/m(3). In addition, the number of different genera present is greater on the DG18 plates than on the MEA plates, on average, 2.85 types vs 1.72. This study suggests that in a hospital environment with 24-h, central air conditioning, DG18 plates appear to be more effective in collecting more fungal colonies in terms of both quantity and types of genera. Such a finding is presumed to be attributed to the characteristic of DG18 in slowing colony growth so that the dominating genus will not over occupy

  15. Combined-sewer overflow data and methods of sample collection for selected sites, Detroit, Michigan

    USGS Publications Warehouse

    Sweat, M.J.; Wolf, J.R.

    1997-01-01

    The discharge of untreated sewage is illegal in Michigan unless permitted under Act 245 due to public health concerns. In October, 1992, the Michigan Department of Natural Resources (MDNR, now the Michigan Department of Environmental Quality) issued a discharge permit to Detroit authorizing discharge from the City's 78 combined-sewer overflows (CSOs), and requiring that a long-term control plan be developed to achieve mandated waterquality standards in receiving waters. The U.S. Environmental Protection Agency (USEPA) issued a national CSO policy in April, 1994, which requires (1) operational improvements of existing systems to minimize discharges and prevent their occurrence in dry weather; (2) publicly operated treatment works (POTW) to characterize the frequency and volume of discharges; and (3) construction of CSO discharge control projects where necessary.In 1993, the Southeast Michigan Council of Governments (SEMCOG) requested assistance from the U.S. Geological Survey (USGS), in cooperation with Detroit Water and Sewerage Department (DWSD) and MDNR, Surface Water Quality Division, to address part of the technical data requirements for requirement 2. The USGS scope of services for this interdisciplinary, multiagency investigation consisted of collection, compilation, and interpretation of the necessary hydrologic data, and documentation of results. In addition to USGS personnel, personnel from DWSD assisted with the field collection of samples and in alerting USGS personnel to CSO effluent discharges.From October 1, 1994 through December 31, 1995, four CSOs discharging to the Detroit River in Detroit, Michigan (figure 1) were monitored to characterize storm-related water quantity and quality. Water velocity, stage, and precipitation were measured continuously and recorded at 5-minute intervals. Water-quality samples were collected at discrete times during storms and analyzed for inorganic and organic pollutants. Discharges were sampled between 30 and 78 times

  16. The representativeness of pore water samples collected from the unsaturated zone using pressure-vacuum lysimeters

    USGS Publications Warehouse

    Peters, C.A.; Healy, R.W.

    1988-01-01

    Studies have indicated that the chemistry of water samples may be altered by the collection technique, creating concern about the representativeness of the pore water samples obtained. A study using soil water pressure-vacuum lysimeters in outwash sand and glacial till deposits demonstrates that for non-dilute-solution samples the effect of pH of sampling with lysimeters is minimal, and that measured major cation and anion concentrations are representative of the natural pore water; trace-metal concentrations can be significantly altered by collection procedures at low concentrations. -from Authors

  17. DISTRIBUTION COEFICIENTS (KD) GENERATED FROM A CORE SAMPLE COLLECTED FROM THE SALTSTONE DISPOSAL FACILITY

    SciTech Connect

    Almond, P.; Kaplan, D.

    2011-04-25

    Core samples originating from Vault 4, Cell E of the Saltstone Disposal Facility (SDF) were collected in September of 2008 (Hansen and Crawford 2009, Smith 2008) and sent to SRNL to measure chemical and physical properties of the material including visual uniformity, mineralogy, microstructure, density, porosity, distribution coefficients (K{sub d}), and chemical composition. Some data from these experiments have been reported (Cozzi and Duncan 2010). In this study, leaching experiments were conducted with a single core sample under conditions that are representative of saltstone performance. In separate experiments, reducing and oxidizing environments were targeted to obtain solubility and Kd values from the measurable species identified in the solid and aqueous leachate. This study was designed to provide insight into how readily species immobilized in saltstone will leach from the saltstone under oxidizing conditions simulating the edge of a saltstone monolith and under reducing conditions, targeting conditions within the saltstone monolith. Core samples were taken from saltstone poured in December of 2007 giving a cure time of nine months in the cell and a total of thirty months before leaching experiments began in June 2010. The saltstone from Vault 4, Cell E is comprised of blast furnace slag, class F fly ash, portland cement, and Deliquification, Dissolution, and Adjustment (DDA) Batch 2 salt solution. The salt solution was previously analyzed from a sample of Tank 50 salt solution and characterized in the 4QCY07 Waste Acceptance Criteria (WAC) report (Zeigler and Bibler 2009). Subsequent to Tank 50 analysis, additional solution was added to the tank solution from the Effluent Treatment Project as well as from inleakage from Tank 50 pump bearings (Cozzi and Duncan 2010). Core samples were taken from three locations and at three depths at each location using a two-inch diameter concrete coring bit (1-1, 1-2, 1-3; 2-1, 2-2, 2-3; 3-1, 3-2, 3-3) (Hansen and

  18. Vacuum hand pump apparatus for collecting water samples from a horizontal intragravel pipe

    USGS Publications Warehouse

    Saiki, Michael K.; Martin, Barbara A.

    1996-01-01

    We describe a lightweight, portable vacuum hand pump apparatus for use in collecting water samples from horizontal intragravel pipe samplers buried in the stream bottom. The apparatus is easily fabricated from relatively inexpensive materials available at many laboratory supply houses.

  19. 75 FR 79033 - Proposed Extension of Existing Information Collection; Radiation Sampling and Exposure Records...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-17

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF LABOR Mine Safety and Health Administration Proposed Extension of Existing Information Collection; Radiation Sampling and Exposure Records (Pertains to Underground Metal and Nonmetal Mines) AGENCY: Mine Safety...

  20. Validation of a Novel Collection Device for Non-Invasive Urine Sampling from Free-Ranging Animals

    PubMed Central

    Danish, Lisa Michelle; Heistermann, Michael; Agil, Muhammad; Engelhardt, Antje

    2015-01-01

    Recent advances in non-invasively collected samples have opened up new and exciting opportunities for wildlife research. Different types of samples, however, involve different limitations and certain physiological markers (e.g., C-peptide, oxytocin) can only be reliably measured from urine. Common collection methods for urine to date work best for arboreal animals and large volumes of urine. Sufficient recovery of urine is thus still difficult for wildlife biologists, particularly for terrestrial and small bodied animals. We tested three collection devices (two commercially available saliva swabs, Salivette synthetic and cotton, and cotton First aid swabs) against a control to permit the collection of small volumes of urine from the ground. We collected urine samples from captive and wild macaques, and humans, measured volume recovery, and analyzed concentrates of selected physiological markers (creatinine, C-peptide, and neopterin). The Salivette synthetic device was superior to the two alternative devices. Concentrations of creatinine, absolute C-peptide, C-peptide per creatinine, absolute neopterin, and neopterin per creatinine measured in samples collected with this device did not differ significantly from the control and were also strongly correlated to it. Fluid recovery was also best for this device. The least suitable device is the First aid collection device; we found that while absolute C-peptide and C-peptide per creatinine concentrations did not differ significantly from the control, creatinine concentrations were significantly lower than the control. In addition, these concentrations were either not or weakly correlated to the control. The Salivette cotton device provided intermediate results, although these concentrations were strongly correlated to the control. Salivette synthetic swabs seem to be useful devices for the collection of small amounts of urine from the ground destined for the assessment of physiological parameters. They thus provide new

  1. Validation of a Novel Collection Device for Non-Invasive Urine Sampling from Free-Ranging Animals.

    PubMed

    Danish, Lisa Michelle; Heistermann, Michael; Agil, Muhammad; Engelhardt, Antje

    2015-01-01

    Recent advances in non-invasively collected samples have opened up new and exciting opportunities for wildlife research. Different types of samples, however, involve different limitations and certain physiological markers (e.g., C-peptide, oxytocin) can only be reliably measured from urine. Common collection methods for urine to date work best for arboreal animals and large volumes of urine. Sufficient recovery of urine is thus still difficult for wildlife biologists, particularly for terrestrial and small bodied animals. We tested three collection devices (two commercially available saliva swabs, Salivette synthetic and cotton, and cotton First aid swabs) against a control to permit the collection of small volumes of urine from the ground. We collected urine samples from captive and wild macaques, and humans, measured volume recovery, and analyzed concentrates of selected physiological markers (creatinine, C-peptide, and neopterin). The Salivette synthetic device was superior to the two alternative devices. Concentrations of creatinine, absolute C-peptide, C-peptide per creatinine, absolute neopterin, and neopterin per creatinine measured in samples collected with this device did not differ significantly from the control and were also strongly correlated to it. Fluid recovery was also best for this device. The least suitable device is the First aid collection device; we found that while absolute C-peptide and C-peptide per creatinine concentrations did not differ significantly from the control, creatinine concentrations were significantly lower than the control. In addition, these concentrations were either not or weakly correlated to the control. The Salivette cotton device provided intermediate results, although these concentrations were strongly correlated to the control. Salivette synthetic swabs seem to be useful devices for the collection of small amounts of urine from the ground destined for the assessment of physiological parameters. They thus provide new

  2. The Internet of Samples in the Earth Sciences: Providing Access to Uncurated Collections

    NASA Astrophysics Data System (ADS)

    Carter, M. R.; Lehnert, K. A.

    2014-12-01

    Vast amounts of physical samples have been collected in the Earth Sciences for studies that address a wide range of scientific questions. Only a fraction of these samples are well curated and preserved long-term in sample repositories and museums. Many samples and collections are stored in the offices and labs of investigators, or in basements and sheds of institutions and investigators' homes. These 'uncurated' collections often contain samples that have been well studied, or are unique and irreplaceable. They may also include samples that could reveal new insights if re-analyzed using new techniques, or specimens that could have unanticipated relevance to research being conducted in fields other than the one for which they were collected. Currently, these samples cannot be accessed or discovered online by the broader science community. Investigators and departments often lack the resources to properly catalog and curate the samples and respond to requests for splits. Long-term preservation of and access to these samples is usually not provided for. iSamplES, a recently-funded EarthCube Research Coordination Network (RCN), seeks to integrate scientific samples, including 'uncurated' samples, into digital data and information infrastructure in the Earth Sciences and to facilitate their curation, discovery, access, sharing, and analysis. The RCN seeks to develop and implement best practices that increase digital access to samples with the goal of establishing a comprehensive infrastructure not only for the digital, but also physical curation of samples. The RCN will engage a broad group of individuals from domain scientists to curators to publishers to computer scientists to define, articulate, and address the needs and challenges of digital sample management and recommend community-endorsed best practices and standards for registering, describing, identifying, and citing physical specimens, drawing upon other initiatives and existing or emerging software tools for

  3. Collecting Samples of Workplace Air. Module 8. Vocational Education Training in Environmental Health Sciences.

    ERIC Educational Resources Information Center

    Consumer Dynamics Inc., Rockville, MD.

    This module, one of 25 on vocational education training for careers in environmental health occupations, contains self-instructional materials on collecting samples of workplace air. Following guidelines for students and instructors and an introduction that explains what the student will learn are three lessons: (1) collecting information about…

  4. OSIRIS-REx Touch-and-Go (TAG) Mission Design for Asteroid Sample Collection

    NASA Technical Reports Server (NTRS)

    May, Alexander; Sutter, Brian; Linn, Timothy; Bierhaus, Beau; Berry, Kevin; Mink, Ron

    2014-01-01

    The Origins Spectral Interpretation Resource Identification Security Regolith Explorer (OSIRIS-REx) mission is a NASA New Frontiers mission launching in September 2016 to rendezvous with the near-Earth asteroid Bennu in October 2018. After several months of proximity operations to characterize the asteroid, OSIRIS-REx flies a Touch-And-Go (TAG) trajectory to the asteroid's surface to collect at least 60 g of pristine regolith sample for Earth return. This paper provides mission and flight system overviews, with more details on the TAG mission design and key events that occur to safely and successfully collect the sample. An overview of the navigation performed relative to a chosen sample site, along with the maneuvers to reach the desired site is described. Safety monitoring during descent is performed with onboard sensors providing an option to abort, troubleshoot, and try again if necessary. Sample collection occurs using a collection device at the end of an articulating robotic arm during a brief five second contact period, while a constant force spring mechanism in the arm assists to rebound the spacecraft away from the surface. Finally, the sample is measured quantitatively utilizing the law of conservation of angular momentum, along with qualitative data from imagery of the sampling device. Upon sample mass verification, the arm places the sample into the Stardust-heritage Sample Return Capsule (SRC) for return to Earth in September 2023.

  5. 76 FR 64366 - Notice of Proposed Information Collection for Public Comment: Additional On-Site Data Collection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-18

    ... HCV programs. The proposed data collection will take place through site visits to up to 30 PHAs and... study of administrative fees in the HCV program. The national study of administrative fees will include... administrative fee allocation formula for the HCV program. OMB Approval Number: Pending. Agency form...

  6. Influence of sexual stimulation on sperm parameters in semen samples collected via masturbation from normozoospermic men or cryptozoospermic men participating in an assisted reproduction programme.

    PubMed

    Yamamoto, Y; Sofikitis, N; Mio, Y; Miyagawa, I

    2000-05-01

    To evaluate the influence of sexual stimulation via sexually stimulating videotaped visual images (VIM) on sperm function, two semen samples were collected from each of 19 normozoospermic men via masturbation with VIM. Two additional samples were collected from each man via masturbation without VIM. The volume of seminal plasma, total sperm count, sperm motility, percentage of morphologically normal spermatozoa, outcome of hypo-osmotic swelling test and zona-free hamster oocyte sperm penetration assay, and markers of the secretory function of prostate were significantly larger in semen samples collected via masturbation with VIM than masturbation without VIM. The improved sperm parameters in the samples collected via masturbation with VIM may reflect an enhanced prostatic secretory function and increased loading of the vas deferens at that time. In a similar protocol, two semen samples were collected via masturbation with VIM from each of 22 non-obstructed azoospermic men. Semen samples from these men had been occasionally positive in the past for a very small number of spermatozoa (cryptozoospermic men). Two additional samples were collected from each cryptozoospermic man via masturbation without VIM. The volume of seminal plasma, total sperm count, sperm motility, and a marker of the secretory function of prostate were significantly larger in semen samples collected via masturbation with VIM. Fourteen out of the 22 men were negative for spermatozoa in both samples collected via masturbation without VIM. These men demonstrated spermatozoa in both samples collected via masturbation with VIM. Six men with immotile spermatozoa in both samples collected via masturbation without VIM exposed motile spermatozoa in both samples collected via masturbation with VIM. High sexual stimulation during masturbation with VIM results in recovery of spermatozoa of greater fertilizing potential both in normozoospermic and cryptozoospermic men. The appearance of spermatozoa after

  7. Efficiency of Different Sampling Tools for Aquatic Macroinvertebrate Collections in Malaysian Streams

    PubMed Central

    Ghani, Wan Mohd Hafezul Wan Abdul; Rawi, Che Salmah Md; Hamid, Suhaila Abd; Al-Shami, Salman Abdo

    2016-01-01

    This study analyses the sampling performance of three benthic sampling tools commonly used to collect freshwater macroinvertebrates. Efficiency of qualitative D-frame and square aquatic nets were compared to a quantitative Surber sampler in tropical Malaysian streams. The abundance and diversity of macroinvertebrates collected using each tool evaluated along with their relative variations (RVs). Each tool was used to sample macroinvertebrates from three streams draining different areas: a vegetable farm, a tea plantation and a forest reserve. High macroinvertebrate diversities were recorded using the square net and Surber sampler at the forested stream site; however, very low species abundance was recorded by the Surber sampler. Relatively large variations in the Surber sampler collections (RVs of 36% and 28%) were observed for the vegetable farm and tea plantation streams, respectively. Of the three sampling methods, the square net was the most efficient, collecting a greater diversity of macroinvertebrate taxa and a greater number of specimens (i.e., abundance) overall, particularly from the vegetable farm and the tea plantation streams (RV<25%). Fewer square net sample passes (<8 samples) were sufficient to perform a biological assessment of water quality, but each sample required a slightly longer processing time (±20 min) compared with those gathered via the other samplers. In conclusion, all three apparatuses were suitable for macroinvertebrate collection in Malaysian streams and gathered assemblages that resulted in the determination of similar biological water quality classes using the Family Biotic Index (FBI) and the Biological Monitoring Working Party (BMWP). However, despite a slightly longer processing time, the square net was more efficient (lowest RV) at collecting samples and more suitable for the collection of macroinvertebrates from deep, fast flowing, wadeable streams with coarse substrates. PMID:27019685

  8. Adsorptive Films in Support of In-field UF6 Destructive Assay Sample Collection and Analysis

    SciTech Connect

    Barrett, Christopher A.; Martinez, Alonzo; McNamara, Bruce K.; Cannon, Bret D.; Anheier, Norman C.

    2014-07-20

    International Atom Energy Agency (IAEA) safeguard verification measures in gaseous centrifuge enrichment plants (GCEPs) rely on environmental sampling, non-destructive assay (NDA), and destructive assay (DA) sampling and analysis to determine uranium enrichment. UF6 bias defect measurements are made by DA sampling and analysis to assure that enrichment is consistent with declarations. DA samples are collected from a limited number of cylinders for high precision, offsite mass spectrometer analysis. Samples are typically drawn from a sampling tap into a UF6 sample bottle, then packaged, sealed, and shipped under IAEA chain of custody to an offsite analytical laboratory. Future DA safeguard measures may require improvements in efficiency and effectiveness as GCEP capacities increase and UF6 shipping regulations become increasingly more restrictive. The Pacific Northwest National Laboratory (PNNL) DA sampler concept and Laser Ablation Absorption Ratio Spectrometry (LAARS) assay method are under development to potentially provide DA safeguard tools that increase inspection effectiveness and reduce sample shipping constraints. The PNNL DA sampler concept uses a handheld sampler to collect DA samples for either onsite LAARS assay or offsite laboratory analysis. The DA sampler design will use a small sampling planchet that is coated with an adsorptive film to collect controlled quantities of UF6 gas directly from a cylinder or process sampling tap. Development efforts are currently underway at PNNL to enhance LAARS assay performance to allow high-precision onsite bias defect measurements. In this paper, we report on the experimental investigation to develop adsorptive films for the PNNL DA sampler concept. These films are intended to efficiently capture UF6 and then stabilize the collected DA sample prior to onsite LAARS or offsite laboratory analysis. Several porous material composite films were investigated, including a film designed to maximize the chemical adsorption

  9. Soil sample collection and analysis for the Fugitive Dust Characterization Study

    NASA Astrophysics Data System (ADS)

    Ashbaugh, Lowell L.; Carvacho, Omar F.; Brown, Michael S.; Chow, Judith C.; Watson, John G.; Magliano, Karen C.

    A unique set of soil samples was collected as part of the Fugitive Dust Characterization Study. The study was carried out to establish whether or not source profiles could be constructed using novel analytical methods that could distinguish soil dust sources from each other. The soil sources sampled included fields planted in cotton, almond, tomato, grape, and safflower, dairy and feedlot facilities, paved and unpaved roads (both urban and rural), an agricultural staging area, disturbed land with salt buildup, and construction areas where the topsoil had been removed. The samples were collected using a systematic procedure designed to reduce sampling bias, and were stored frozen to preserve possible organic signatures. For this paper the samples were characterized by particle size (percent sand, silt, and clay), dry silt content (used in EPA-recommended fugitive dust emission factors), carbon and nitrogen content, and potential to emit both PM 10 and PM 2.5. These are not the "novel analytical methods" referred to above; rather, it was the basic characterization of the samples to use in comparing analytical methods by other scientists contracted to the California Air Resources Board. The purpose of this paper is to document the methods used to collect the samples, the collection locations, the analysis of soil type and potential to emit PM 10, and the sample variability, both within field and between fields of the same crop type.

  10. Human Exploration of Near-Earth Asteroids and Sample Collection Considerations

    NASA Technical Reports Server (NTRS)

    Abell, Paul

    2013-01-01

    primitive body would lead to the same kind of breakthroughs for understanding NEAs that the Apollo samples provided for understanding the Earth-Moon system and its formation history. International Participation: In addition, robotic precursor and human exploration missions to NEAs would allow the NASA and its international partners to gain operational experience in performing complex tasks (e.g., sample collection, deployment of payloads, retrieval of payloads, etc.) with crew, robots, and spacecraft under microgravity conditions at or near the surface of a small body. This would provide an important synergy between the worldwide Science and Exploration communities, which will be crucial for development of future international deep space exploration architectures and has potential benefits for future exploration of other destinations beyond low-Earth orbit.

  11. Collecting Comet Samples by ER-2 Aircraft: Cosmic Dust Collection During the Draconid Meteor Shower in October 2012

    NASA Technical Reports Server (NTRS)

    Bastien, Ron; Burkett, P. J.; Rodriquez, M.; Frank, D.; Gonzalez, C.; Robinson, G.-A.; Zolensky, M.; Brown, P.; Campbell-Brown, M.; Broce, S.; Kapitzke, M.; Moes, T.; Steel, D.; Williams, T.; Gearheart, D.

    2014-01-01

    Many tons of dust grains, including samples of asteroids and comets, fall from space into the Earth's atmosphere each day. NASA periodically collects some of these particles from the Earth's stratosphere using sticky collectors mounted on NASA's high-flying aircraft. Sometimes, especially when the Earth experiences a known meteor shower, a special opportunity is presented to associate cosmic dust particles with a known source. NASA JSC's Cosmic Dust Collection Program has made special attempts to collect dust from particular meteor showers and asteroid families when flights can be planned well in advance. However, it has rarely been possible to make collections on very short notice. In 2012, the Draconid meteor shower presented that opportunity. The Draconid meteor shower, originating from Comet 21P/Giacobini-Zinner, has produced both outbursts and storms several times during the last century, but the 2012 event was not predicted to be much of a show. Because of these predictions, the Cosmic Dust team had not targeted a stratospheric collection effort for the Draconids, despite the fact that they have one of the slowest atmospheric entry velocities (23 km/s) of any comet shower, and thus offer significant possibilities of successful dust capture. However, radar measurements obtained by the Canadian Meteor Orbit Radar during the 2012 Draconids shower indicated a meteor storm did occur October 8 with a peak at 16:38 (+/-5 min) UTC for a total duration of approximately 2 hours.

  12. Magnetic Properties of Lunar Samples: an Exhaustive Survey of the Apollo Collection

    NASA Astrophysics Data System (ADS)

    Gattacceca, J.; Andrade Lima, E.; Rochette, P.; Weiss, B. P.; Uehara, M.; Quesnel, Y.; Baratchart, L.; Leblond, J.; Chevillard, S.

    2014-12-01

    Detailed paleomagnetic studies of lunar samples shed light on the existence and timing of the ancient lunar dynamo, with insights to the inner structure and thermal evolution of the Moon, as well as constraints for the lunar dynamo models [e.g., 1-6]. However these studies are usually performed on small cm-scale samples, typically below 100 mg. Such a small size, combined with anisotropy and other spurious effects have been shown to be the source of additional complexity [7]. We measured the natural remanent magnetization and magnetic susceptibility of 105 large Apollo samples (mass range 40 g to 2.9 kg, median mass 350 g). For this, following the approach utilized for the initial paleomagnetic evaluation of Apollo 11 samples [8], we developed a dedicated magnetometer using a fluxgate sensor and a rotating stage, which allowed measuring the bulk samples in their original Teflon and aluminum packaging under nitrogen atmosphere. Despite a number of caveats (no demagnetization steps, existence of viscous magnetization and other soft secondary magnetization), the ratio of natural remanent magnetization to susceptibility gives a rough estimate of the paleointensity. The evolution of the paleointensity with the estimated age of the samples will provide a broad picture of the evolution of the lunar dynamo. Susceptibility, as a proxy to the bulk metal content in lunar rocks [9], is also a valuable source of information per se but is currently available only for a small fraction of the Apollo collection. Our survey will allow identification of rocks with unusual magnetic properties, and therefore potentially unusual petrogenesis. References: [1] Fuller & Cisowski 1987. In Jacobs (Ed.) Geomagnetism, 307-455 [2] Garrick-Bethell et al. 2009. Science 323:356-359 [3] Cournède et al. 2012. EPSL 33:31-42 [4] Shea et al. 2012. Science 335:453-456 [5] Suavet et al. 2013. PNAS 110:8453-8456 [6] Tikoo et al. 2014. EPSL in press [7] Tikoo et al. 2012. EPSL 337:93-103 [8] Doell & Gromm

  13. JSC Advanced Curation: Research and Development for Current Collections and Future Sample Return Mission Demands

    NASA Technical Reports Server (NTRS)

    Fries, M. D.; Allen, C. C.; Calaway, M. J.; Evans, C. A.; Stansbery, E. K.

    2015-01-01

    Curation of NASA's astromaterials sample collections is a demanding and evolving activity that supports valuable science from NASA missions for generations, long after the samples are returned to Earth. For example, NASA continues to loan hundreds of Apollo program samples to investigators every year and those samples are often analyzed using instruments that did not exist at the time of the Apollo missions themselves. The samples are curated in a manner that minimizes overall contamination, enabling clean, new high-sensitivity measurements and new science results over 40 years after their return to Earth. As our exploration of the Solar System progresses, upcoming and future NASA sample return missions will return new samples with stringent contamination control, sample environmental control, and Planetary Protection requirements. Therefore, an essential element of a healthy astromaterials curation program is a research and development (R&D) effort that characterizes and employs new technologies to maintain current collections and enable new missions - an Advanced Curation effort. JSC's Astromaterials Acquisition & Curation Office is continually performing Advanced Curation research, identifying and defining knowledge gaps about research, development, and validation/verification topics that are critical to support current and future NASA astromaterials sample collections. The following are highlighted knowledge gaps and research opportunities.

  14. Comparison of water-quality samples collected by siphon samplers and automatic samplers in Wisconsin

    USGS Publications Warehouse

    Graczyk, David J.; Robertson, Dale M.; Rose, William J.; Steur, Jeffrey J.

    2000-01-01

    In small streams, flow and water-quality concentrations often change quickly in response to meteorological events. Hydrologists, field technicians, or locally hired stream ob- servers involved in water-data collection are often unable to reach streams quickly enough to observe or measure these rapid changes. Therefore, in hydrologic studies designed to describe changes in water quality, a combination of manual and automated sampling methods have commonly been used manual methods when flow is relatively stable and automated methods when flow is rapidly changing. Auto- mated sampling, which makes use of equipment programmed to collect samples in response to changes in stage and flow of a stream, has been shown to be an effective method of sampling to describe the rapid changes in water quality (Graczyk and others, 1993). Because of the high cost of automated sampling, however, especially for studies examining a large number of sites, alternative methods have been considered for collecting samples during rapidly changing stream conditions. One such method employs the siphon sampler (fig. 1). also referred to as the "single-stage sampler." Siphon samplers are inexpensive to build (about $25- $50 per sampler), operate, and maintain, so they are cost effective to use at a large number of sites. Their ability to collect samples representing the average quality of water passing though the entire cross section of a stream, however, has not been fully demonstrated for many types of stream sites.

  15. An instrument for collecting discrete large-volume water samples suitable for ecological studies of microorganisms

    NASA Astrophysics Data System (ADS)

    Wommack, K. Eric; Williamson, Shannon J.; Sundbergh, Arthur; Helton, Rebekah R.; Glazer, Brian T.; Portune, Kevin; Craig Cary, S.

    2004-11-01

    Microbiological investigations utilizing molecular genetic approaches to characterize microbial communities can require large volume water samples, tens to hundreds of liters. The requirement for large volume samples can be especially challenging in deep-sea hydrothermal vent environments of the oceanic ridge system. By and large studies of these environments rely on deep submergence vehicles. However collection of large volume (>100 L) water samples adjacent to the benthos is not feasible due to weight considerations. To address the technical difficulty of collecting large volume water samples from hydrothermal diffuse flow environments, a semi-autonomous large-volume water sampler (LVWS) was designed. The LVWS is capable of reliably collecting and bringing to the surface 120 L water samples from diffuse flow environments. Microscopy, molecular genetic and chemical analyses of water samples taken from 9°N East Pacific Rise are shown to demonstrate the utility of the LVWS for studies of near-benthos environments. To our knowledge this is the first report of virioplankton abundance within diffuse-flow waters of a deep-sea hydrothermal vent environment. Because of its simple design and relatively low cost, the LVWS should be applicable to a variety of studies which require large-volume water samples collected immediately adjacent to the benthos.

  16. Methods for collecting algal samples as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Porter, Stephen D.; Cuffney, Thomas F.; Gurtz, Martin E.; Meador, Michael R.

    1993-01-01

    Benthic algae (periphyton) and phytoplankton communities are characterized in the U.S. Geological Survey's National Water-Quality Assessment Program as part of an integrated physical, chemical, and biological assessment of the Nation's water quality. This multidisciplinary approach provides multiple lines of evidence for evaluating water-quality status and trends, and for refining an understanding of the factors that affect water-quality conditions locally, regionally, and nationally. Water quality can be characterized by evaluating the results of qualitative and quantitative measurements of the algal community. Qualitative periphyton samples are collected to develop of list of taxa present in the sampling reach. Quantitative periphyton samples are collected to measure algal community structure within selected habitats. These samples of benthic algal communities are collected from natural substrates, using the sampling methods that are most appropriate for the habitat conditions. Phytoplankton samples may be collected in large nonwadeable streams and rivers to meet specific program objectives. Estimates of algal biomass (chlorophyll content and ash-free dry mass) also are optional measures that may be useful for interpreting water-quality conditions. A nationally consistent approach provides guidance on site, reach, and habitat selection, as well as information on methods and equipment for qualitative and quantitative sampling. Appropriate quality-assurance and quality-control guidelines are used to maximize the ability to analyze data locally, regionally, and nationally.

  17. Sample collection of virulent and non-virulent B. anthracis and Y. pestis for bioforensics analysis

    SciTech Connect

    Hong-geller, Elizabeth; Valdez, Yolanda E; Shou, Yulin; Yoshida, Thomas M; Marrone, Babetta L; Dunbar, John

    2009-01-01

    Validated sample collection methods are needed for recovery of microbial evidence in the event of accidental or intentional release of biological agents into the environment. To address this need, we evaluated the sample recovery efficiencies of two collection methods -- swabs and wipes -- for both non-virulent and virulent strains of B. anthracis and Y. pestis from four types of non-porous surfaces: two hydrophilic surfaces, stainless steel and glass, and two hydrophobic surfaces, vinyl and plastic. Sample recovery was quantified using Real-time qPCR to assay for intact DNA signatures. We found no consistent difference in collection efficiency between swabs or wipes. Furthermore, collection efficiency was more surface-dependent for virulent strains than non-virulent strains. For the two non-virulent strains, B. anthracis Sterne and Y. pestis A1122, collection efficiency was approximately 100% and 1 %, respectively, from all four surfaces. In contrast, recovery of B. anthracis Ames spores and Y. pestis C092 from vinyl and plastic was generally lower compared to collection from glass or stainless steel, suggesting that surface hydrophobicity may playa role in the strength of pathogen adhesion. The surface-dependent collection efficiencies observed with the virulent strains may arise from strain-specific expression of capsular material or other cell surface receptors that alter cell adhesion to specific surfaces. These findings contribute to validation of standard bioforensics procedures and emphasize the importance of specific strain and surface interactions in pathogen detection.

  18. Establishment of a reference collection of additives and an analytical handbook of reference data to support enforcement of EU regulations on food contact plastics.

    PubMed

    van Lierop, B; Castle, L; Feigenbaum, A; Ehlert, K; Boenke, A

    1998-10-01

    A collection has been made of additives that are required as analytical standards for enforcement of European Union legislation on food contact plastics. The 100 additives have been characterized by mass spectrometry, infra-red spectroscopy and proton nuclear magnetic resonance spectroscopy to provide reference spectra. Gas chromatographic retention times have been recorded to facilitate identification by retention index. This information has been further supplemented by physico-chemical data. Finally, chromatographic methods have been used to indicate the presence of any impurities in the commercial chemicals. Samples of the reference substances are available on request and the collection of spectra and other information will be made available in printed format and on-line through the Internet. This paper gives an overview of the work done to establish the reference collection and the spectral atlas, which together will assist enforcement laboratories in the characterization of plastics and the selection of analytical methods for additives that may migrate.

  19. Insights into explosion dynamics at Stromboli in 2009 from ash samples collected in real-time

    NASA Astrophysics Data System (ADS)

    Taddeucci, J.; Lautze, N.; Andronico, D.; D'Auria, L.; Niemeijer, A.; Houghton, B.; Scarlato, P.

    2012-04-01

    Rapid characterization of tephra during explosive eruptions can provide valuable insights into eruptive mechanisms, also integrating other monitoring systems. Here we reveal a perspective on Stromboli's conduit processes by linking ash textures to geophysical estimates of eruption parameters of observed explosions. A three day campaign at Stromboli was undertaken by Italy's Istituto Nazionale di Geofisica e Vulcanologia (INGV) in October 2009. At this time activity was moderately intense, with an average 4 to 5, both ash-rich and ash-poor, explosions per hour at each the SW and NE vents. A total of fifteen ash samples were collected in real time. We used binocular and scanning electron microscopes to analyze the components, grain size and morphology distributions, and surface chemistry of ash particles within eight selected samples. In addition, the INGV monitoring network provided visual, thermal, and seismic information on the explosions that generated the sampled ash. In each sample, the proportion of fluidal, glassy sideromelane (as opposed to blocky, microcrystalline tachylite plus lithics), the degree of "chemical freshness" (as opposed to chemical alteration), and the average size of particles appear to correlate directly with the maximum height and the seismic amplitude of the corresponding explosion, and inversely correlate with the amount of ash erupted, as estimated by monitoring videos. These observations suggest that more violent explosions (i.e., those driven by the release of larger and more pressurized gas volumes) produce ash via the fragmentation of hotter, more fluid magma, while weaker ones mostly erupt ash-sized particles derived by the fragmentation of colder magma and incorporation of conduit wall debris. The formation of fluidal ash particles (up to Pele's hairs) requires aerodynamic deformation of a relatively low-viscosity magma, in agreement with the strong acceleration imposed upon fragmented magma clots by the rapid expansion of

  20. Additions to the reptile fauna of Paraguay with notes on a small herpetological collection from Amambay

    USGS Publications Warehouse

    McDiarmid, Roy W.; Foster, Mercedes S.

    1987-01-01

    Specimens in a small collections of reptiles and amphibians from Parque Nacional Cerro Cora, Departamento Amambay, Paraguay are reported. Included are the first records of Bachia bresslaui, Phrynops gibbus, and Ololygon fuscomarginata for that country. Brief notes on morphology, distribution, and natural history of species collected are included. The systematic status of Phrynops tuberculatus vanderhaegei is evaluated.

  1. Sample Collection of Ash and Burned Soils from the October 2007 Southern California Wildfires

    USGS Publications Warehouse

    Hoefen, Todd M.; Kokaly, Raymond F.; Martin, Deborah A.; Rochester, Carlton; Plumlee, Geoffrey S.; Mendez, Greg; Reichard, Eric G.; Fisher, Robert N.

    2009-01-01

    Between November 2 through 9, 2007 scientists from the U.S. Geological Survey (USGS) collected samples of ash and burned soils from 28 sites in six areas burned as a result of the Southern California wildfires of October 2007, including the Harris, Witch, Santiago, Ammo, Canyon, and Grass Valley Fires. The primary goal of this sampling and analysis effort was to understand how differences in ash and burned soil composition relate to vegetation type, underlying bedrock geology, burn intensity, and residential versus wildland. Sampling sites were chosen with the input of local experts from the USGS Water Resources and Biological Resources Disciplines to help understand possible effects of the fires on water supplies, ecosystems, and endangered species. The sampling was also carried out in conjunction with detailed field analysis of the spectral reflectance characteristics of the ash, so that chemical and mineralogical characteristics of the field samples could be used to help interpret data collected as part of an airborne, hyperspectral remote-sensing survey of several of the burned areas in mid-late November, 2007. This report presents an overview of the field sampling methodologies used to collect the samples, includes representative photos of the sites sampled, and summarizes important characteristics of each of the collection sites. In this report we use the term 'ash' to refer collectively to white mineral ash, which results from full combustion of vegetation and black charred organic matter from partial combustion of vegetation or other materials. These materials were found to be intermingled as a deposited residue on the soil surface following the Southern California fires of 2007.

  2. Study Design and Percent Recoveries of Anthropogenic Organic Compounds With and Without the Addition of Ascorbic Acid to Preserve Water Samples Containing Free Chlorine, 2004-06

    USGS Publications Warehouse

    Valder, Joshua F.; Delzer, Gregory C.; Price, Curtis V.; Sandstrom, Mark W.

    2008-01-01

    The National Water-Quality Assessment (NAWQA) Program of the U.S. Geological Survey (USGS) began implementing Source Water-Quality Assessments (SWQAs) in 2002 that focus on characterizing the quality of source water and finished water of aquifers and major rivers used by some of the larger community water systems in the United States. As used for SWQA studies, source water is the raw (ambient) water collected at the supply well prior to water treatment (for ground water) or the raw (ambient) water collected from the river near the intake (for surface water). Finished water is the water that is treated, which typically involves, in part, the addition of chlorine or other disinfection chemicals to remove pathogens, and is ready to be delivered to consumers. Finished water is collected before the water enters the distribution system. This report describes the study design and percent recoveries of anthropogenic organic compounds (AOCs) with and without the addition of ascorbic acid to preserve water samples containing free chlorine. The percent recoveries were determined by using analytical results from a laboratory study conducted in 2004 by the USGS's National Water Quality Laboratory (NWQL) and from data collected during 2004-06 for a field study currently (2008) being conducted by the USGS's NAWQA Program. The laboratory study was designed to determine if preserving samples with ascorbic acid (quenching samples) adversely affects analytical performance under controlled conditions. During the laboratory study, eight samples of reagent water were spiked for each of five analytical schedules evaluated. Percent recoveries from these samples were then compared in two ways: (1) four quenched reagent spiked samples analyzed on day 0 were compared with four quenched reagent spiked samples analyzed on day 7 or 14, and (2) the combined eight quenched reagent spiked samples analyzed on day 0, 7, or 14 were compared with eight laboratory reagent spikes (LRSs). Percent

  3. Handbook: Collecting Groundwater Samples from Monitoring Wells in Frenchman Flat, CAU 98

    SciTech Connect

    Chapman, Jenny; Lyles, Brad; Cooper, Clay; Hershey, Ron; Healey, John

    2015-06-01

    CAU. The sampling plan is designed to ensure that monitoring activities occur in compliance with the UGTA Quality Assurance Plan (DOE, 2012). The sampling plan should be referenced for Quality Assurance (QA) elements and procedures governing sampling activities. The NNSS Integrated Sampling Plan specifies the groundwater monitoring that will occur in CAU 98 until the long-term monitoring program is approved in the Closure Report. The plan specifies the wells that must be monitored and categorizes them by their sampling objective with the associated analytical requirements and frequency. Possible sample collection methods and required standard operating procedures are also presented. The intent of this handbook is to augment the NNSS Integrated Sampling Plan by providing well-specific details for the sampling professional implementing the Sampling Plan in CAU 98, Frenchman Flat. This handbook includes each CAU 98 well designated for sampling in the NNSS Integrated Sampling Plan. The following information is provided in the individual well sections: 1. The purpose of sampling. 2. A physical description of the well. 3. The chemical characteristics of the formation water. 4. Recommended protocols for purging and sampling. The well-specific information has been gathered from numerous historical and current sources cited in each section, but two particularly valuable resources merit special mention. These are the USGS NNSS website (http://nevada.usgs.gov/doe_nv/ntsarea5.cfm) and the UGTA Field Operations website (https://ugta.nv.doe.gov/sites/Field%20Operations/default.aspx). 2 Land surface elevation and measuring point for water level measurements in Frenchman Flat were a focus during CAU investigations (see Appendix B, Attachment 1 in Navarro-Intera, 2014). Both websites listed above provide information on the accepted datum for each well. A summary is found on the home page for the well on the USGS website. Additional information is available through a link in the

  4. Multi-element composition of historical lichen collections and bark samples, indicators of changing atmospheric conditions

    NASA Astrophysics Data System (ADS)

    Purvis, O. W.; Chimonides, P. D. J.; Jeffries, T. E.; Jones, G. C.; Rusu, A.-M.; Read, H.

    Thirty six element signatures were compared in historical Parmelia sulcata samples from the Natural History Museum herbarium collected over the period 1797-1967 with those recorded in the same species and tree bark sampled in 2000 from Burnham Beeches, lying 40 km west of London. Nineteen elements reached highest concentrations in herbarium samples, consistent with a pollution legacy and dust contamination in the herbarium. Healthy Parmelia sampled east and down-wind of London at a farm during peak SO 2 emissions in 1967 contained highest V, Ni, Zn, Cd, Se, Ge contents, supporting derivation from fuel combustion; the same sample was previously determined as having a low δ34S and high S and N contents. Lowest V, Co, Ni, Cu, Zn, Sn, Ba, Pb, Mo, Sb, Li, B, Cs, U, Th, Ga contents were recorded in a sample with a high δ34S and low S content collected in 1887 from a remote region from Ross-shire, Scotland. Se and Cd enrichment, never-the-less suggest a transboundary pollution influence. Lichen Pb concentrations from Burnham Beeches were amongst the lowest recorded in spite of lichens being collected close to roads. Herbarium samples help interpret changes in element deposition where few data exist, in spite of dust contamination.

  5. Archival policies and collections database for the Woods Hole Science Center's marine sediment samples

    USGS Publications Warehouse

    Buczkowski, Brian J.; Kelsey, Sarah A.

    2007-01-01

    The Woods Hole Science Center of the U.S. Geological Survey (USGS) has been an active member of the Woods Hole research community, Woods Hole, Massachusetts, for over 40 years. In that time there have been many projects that involved the collection of sediment samples conducted by USGS scientists and technicians for the research and study of seabed environments and processes. These samples were collected at sea or near shore and then brought back to the Woods Hole Science Center (WHSC) for analysis. While at the center, samples are stored in ambient temperature, refrigerated and freezing conditions ranging from +2º Celsius to -18º Celsius, depending on the best mode of preparation for the study being conducted or the duration of storage planned for the samples. Recently, storage methods and available storage space have become a major concern at the WHSC. The core and sediment archive program described herein has been initiated to set standards for the management, methods, and duration of sample storage. A need has arisen to maintain organizational consistency and define storage protocol. This handbook serves as a reference and guide to all parties interested in using and accessing the WHSC's sample archive and also defines all the steps necessary to construct and maintain an organized collection of geological samples. It answers many questions as to the way in which the archive functions.

  6. Investigation of reflectance sampling depth in biological tissues for various common illumination/collection configurations.

    PubMed

    Zonios, George

    2014-09-01

    Knowledge of light penetration characteristics is very important in almost all studies in biomedical optics. In this work, the reflectance sampling depth in biological tissues was investigated using Monte Carlo simulations for various common illumination/collection configurations. The analysis shows that the average sampling depth can be described by two simple empirical analytical expressions over the entire typical ranges of absorption and scattering properties relevant to in vivo biological tissue, regardless of the specific illumination/collection configuration details. These results are promising and helpful for the quick, efficient, and accurate design of reflectance studies for various biological tissue applications.

  7. Satisfaction survey with DNA cards method to collect genetic samples for pharmacogenetics studies

    PubMed Central

    Vidal-Taboada, Jose M; Cucala, Mercedes; Mas Herrero, Sergio; Lafuente, Amalia; Cobos, Albert

    2006-01-01

    Background Pharmacogenetic studies are essential in understanding the interindividual variability of drug responses. DNA sample collection for genotyping is a critical step in genetic studies. A method using dried blood samples from finger-puncture, collected on DNA-cards, has been described as an alternative to the usual venepuncture technique. The purpose of this study is to evaluate the implementation of the DNA cards method in a multicentre clinical trial, and to assess the degree of investigators' satisfaction and the acceptance of the patients perceived by the investigators. Methods Blood samples were collected on DNA-cards. The quality and quantity of DNA recovered were analyzed. Investigators were questioned regarding their general interest, previous experience, safety issues, preferences and perceived patient satisfaction. Results 151 patients' blood samples were collected. Genotyping of GST polymorphisms was achieved in all samples (100%). 28 investigators completed the survey. Investigators perceived patient satisfaction as very good (60.7%) or good (39.3%), without reluctance to finger puncture. Investigators preferred this method, which was considered safer and better than the usual methods. All investigators would recommend using it in future genetic studies. Conclusion Within the clinical trial setting, the DNA-cards method was very well accepted by investigators and patients (in perception of investigators), and was preferred to conventional methods due to its ease of use and safety. PMID:16681846

  8. Application of bar codes to the automation of analytical sample data collection

    SciTech Connect

    Jurgensen, H A

    1986-01-01

    The Health Protection Department at the Savannah River Plant collects 500 urine samples per day for tritium analyses. Prior to automation, all sample information was compiled manually. Bar code technology was chosen for automating this program because it provides a more accurate, efficient, and inexpensive method for data entry. The system has three major functions: sample labeling is accomplished at remote bar code label stations composed of an Intermec 8220 (Intermec Corp.) interfaced to an IBM-PC, data collection is done on a central VAX 11/730 (Digital Equipment Corp.). Bar code readers are used to log-in samples to be analyzed on liquid scintillation counters. The VAX 11/730 processes the data and generates reports, data storage is on the VAX 11/730 and backed up on the plant's central computer. A brief description of several other bar code applications at the Savannah River Plant is also presented.

  9. Collection of a Lifetime: A Practical Approach to Developing a Longitudinal Collection of Women’s Healthcare Biological Samples

    PubMed Central

    Santillan, Mark K.; Leslie, Kimberly K.; Hamilton, Wendy S.; Boese, Brenda J.; Ahuja, Monika; Hunter, Stephen K.; Santillan, Donna A.

    2014-01-01

    Objective The objective is to develop a biorepository of samples that represent all stages of a women’s life. Importantly, our goal is to collect longitudinal physical specimens as well as the associated short and long-term clinical information. Study Design The Women’s Health Tissue Repository was established to encompass four tissue banks: Well Women Tissue Bank, Reproductive Endocrinology & Infertility Tissue Bank, Maternal Fetal Tissue Bank, and the long-established Gynecologic Malignancies Tissue Bank. Based on their health status, women being seen in Women’s Health at the University of Iowa are recruited to contribute samples and grant access to their electronic medical record to the biorepository. Samples are coded, processed, and stored for use by investigators. Results The Maternal Fetal Tissue Bank was the first expansion of our department’s biobanking efforts. Approximately 75% of the women approached consent to participate in the Maternal Fetal Tissue Bank. Enrollment has steadily increased. Samples have been used for over 20 projects in the first 3 years and are critical to 7 funded grants and 3 patent applications. Conclusion Patient samples with corresponding clinical data are initially important to women’s health research. Our model demonstrates that many research projects by faculty, fellows, and residents have benefited from the existence of the Women’s Health Tissue Repository. While challenging to achieve, longitudinal sampling allows for the greatest opportunity to study normal and pathological changes throughout all phases of a women’s life, including pregnancy. This bank facilitates and accelerates the development of novel research, technologies, and possible therapeutic options in women’s health. The establishment of more longitudinal biorepositories based on our model would enhance women’s health research. PMID:24965987

  10. An unmanned mission to Mars with sample collection and in-situ resource utilization

    NASA Astrophysics Data System (ADS)

    1994-05-01

    The design for the Mars Analysis and Return Vehicle with In-Situ Resource Utilization (MARVIN) project is outlined. The MARVIN mission is designed to collect samples of the Martian environment; to produce fuel from local Martian resources; and to use the fuel produced to return the samples to earth. It uses only existing technologies. Exploratory Technologies' mission-design efforts have focused on methods of orbit determination, sample collection, fuel production, power, communications, control, and structural design. Lambert Targeting provided Delta-V's, launch dates, and travel times. The landing site is the Tharsis Plateau, to the southeast of Olympus Mons, chosen for its substantial scientific value. Samples of soil, dust, and atmosphere are collected with lander-based collection devices: the soil sample, with a robotic arm similar to those used in the Viking missions; the atmospheric sample, from a bleed line to the compressor in the fuel-production facility; a dust sample, from the dust-collection container in the fuel-production facility; and a redundant dust sample, with a with a passive filter system, which relies upon neither a power source nor other collection methods. The sample-return capsule (SRC) houses these samples, which are triply contained to prevent contamination. Proven technology can be used to produce methane and oxygen for fuel with relative ease at the landing site: the Sabatier reactor produces methane and water by combining carbon dioxide and hydrogen (brought from earth); the Reverse Water-Gas Shift unit combines carbon dioxide and hydrogen to form carbon monoxide and water; a water-electrolysis unit splits the water into hydrogen and oxygen. The Mars-lander vehicle (MLV) transports the equipment from earth to Mars. The Mars-ascent vehicle (MAV) contains the SRC and the engine, which is the same for both the MLV and the MAV. All equipment that is unnecessary for the Mars-Earth trajectory remains on Mars. This report presents detailed

  11. An unmanned mission to Mars with sample collection and in-situ resource utilization

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The design for the Mars Analysis and Return Vehicle with In-Situ Resource Utilization (MARVIN) project is outlined. The MARVIN mission is designed to collect samples of the Martian environment; to produce fuel from local Martian resources; and to use the fuel produced to return the samples to earth. It uses only existing technologies. Exploratory Technologies' mission-design efforts have focused on methods of orbit determination, sample collection, fuel production, power, communications, control, and structural design. Lambert Targeting provided Delta-V's, launch dates, and travel times. The landing site is the Tharsis Plateau, to the southeast of Olympus Mons, chosen for its substantial scientific value. Samples of soil, dust, and atmosphere are collected with lander-based collection devices: the soil sample, with a robotic arm similar to those used in the Viking missions; the atmospheric sample, from a bleed line to the compressor in the fuel-production facility; a dust sample, from the dust-collection container in the fuel-production facility; and a redundant dust sample, with a with a passive filter system, which relies upon neither a power source nor other collection methods. The sample-return capsule (SRC) houses these samples, which are triply contained to prevent contamination. Proven technology can be used to produce methane and oxygen for fuel with relative ease at the landing site: the Sabatier reactor produces methane and water by combining carbon dioxide and hydrogen (brought from earth); the Reverse Water-Gas Shift unit combines carbon dioxide and hydrogen to form carbon monoxide and water; a water-electrolysis unit splits the water into hydrogen and oxygen. The Mars-lander vehicle (MLV) transports the equipment from earth to Mars. The Mars-ascent vehicle (MAV) contains the SRC and the engine, which is the same for both the MLV and the MAV. All equipment that is unnecessary for the Mars-Earth trajectory remains on Mars. This report presents detailed

  12. Contamination Knowledge Strategy for the Mars 2020 Sample-Collecting Rover

    NASA Technical Reports Server (NTRS)

    Farley, K. A.; Williford, K.; Beaty, D W.; McSween, H. Y.; Czaja, A. D.; Goreva, Y. S.; Hausrath, E.; Herd, C. D. K.; Humayun, M.; McCubbin, F. M.; McLennan, S. M.; Pratt, L. M.; Sephton, M. A.; Steele, A.; Weiss, B. P.; Hays, L. E.

    2017-01-01

    The Mars 2020 rover will collect carefully selected samples of rock and regolith as it explores a potentially habitable ancient environment on Mars. Using the drill, rock cores and regolith will be collected directly into ultraclean sample tubes that are hermetically sealed and, later, deposited on the surface of Mars for potential return to Earth by a subsequent mission. Thorough characterization of any contamination of the samples at the time of their analysis will be essential for achieving the objectives of Mars returned sample science (RSS). We refer to this characterization as contamination knowledge (CK), which is distinct from contamination control (CC). CC is the set of activities that limits the input of contaminating species into a sample, and is specified by requirement thresholds. CK consists of identifying and characterizing both potential and realized contamination to better inform scientific investigations of the returned samples. Based on lessons learned by other sample return missions with contamination-sensitive scientific objectives, CC needs to be "owned" by engineering, but CK needs to be "owned" by science. Contamination present at the time of sample analysis will reflect the sum of contributions from all contamination vectors up to that point in time. For this reason, understanding the integrated history of contamination may be crucial for deciphering potentially confusing contaminant-sensitive observations. Thus, CK collected during the Mars sample return (MSR) campaign must cover the time period from the initiation of hardware construction through analysis of returned samples in labs on Earth. Because of the disciplinary breadth of the scientific objectives of MSR, CK must include a broad spectrum of contaminants covering inorganic (i.e., major, minor, and trace elements), organic, and biological molecules and materials.

  13. Sources of variability in collection and preparation of paint and lead-coating samples.

    PubMed

    Harper, S L; Gutknecht, W F

    2001-06-01

    Chronic exposure of children to lead (Pb) can result in permanent physiological impairment. Since surfaces coated with lead-containing paints and varnishes are potential sources of exposure, it is extremely important that reliable methods for sampling and analysis be available. The sources of variability in the collection and preparation of samples were investigated to improve the performance and comparability of methods and to ensure that data generated will be adequate for its intended use. Paint samples of varying sizes (areas and masses) were collected at different locations across a variety of surfaces including metal, plaster, concrete, and wood. A variety of grinding techniques were compared. Manual mortar and pestle grinding for at least 1.5 min and mechanized grinding techniques were found to generate similar homogenous particle size distributions required for aliquots as small as 0.10 g. When 342 samples were evaluated for sample weight loss during mortar and pestle grinding, 4% had 20% or greater loss with a high of 41%. Homogenization and sub-sampling steps were found to be the principal sources of variability related to the size of the sample collected. Analysis of samples from different locations on apparently identical surfaces were found to vary by more than a factor of two both in Pb concentration (mg cm-2 or %) and areal coating density (g cm-2). Analyses of substrates were performed to determine the Pb remaining after coating removal. Levels as high as 1% Pb were found in some substrate samples, corresponding to more than 35 mg cm-2 Pb. In conclusion, these sources of variability must be considered in development and/or application of any sampling and analysis methodologies.

  14. Technical note: Bacterial diversity and fermentation end products in rumen fluid samples collected via oral lavage or rumen cannula.

    PubMed

    Lodge-Ivey, S L; Browne-Silva, J; Horvath, M B

    2009-07-01

    A study was conducted to determine if sampling rumen contents via a ruminal cannula or oral lavage tube would yield similar denaturing gradient gel electrophoresis profiles of the bacterial community. Two species of ruminally cannulated animals were used for this study (cattle, n = 2; sheep, n = 3). All animals were allowed ad libitum access to feed. Cattle were fed baled unprocessed sorghum-sudan hay (12% CP, 68% NDF; DM basis), whereas sheep were maintained on chopped alfalfa (18% CP, 40% NDF; DM basis). Ruminal fluid was collected (approximately 20 mL) once per week for 3 wk from each animal using a poly tube equipped with a suction strainer with a hand-held suction pump through the rumen cannula or oral cavity. The denaturing gradient gel electrophoresis analysis demonstrates that yield of bacterial diversity was not different between the 2 sampling methods (P = 0.73). When samples were grouped according to band pattern similarity, groups were most stable according to individual animal and species rather than sampling method. Total VFA and molar proportions of individual VFA did not differ by sampling method (P > 0.40). Additionally, rumen ammonia concentrations were similar for both sampling methods (19.3 vs. 19.1 mM +/- 8.0 for cannula vs. lavage, respectively; P = 0.98). These data indicate that rumen samples collected via oral lavage or rumen cannula yield similar results. This knowledge will allow sample collection from a greater population of animals and an ability to maintain the value of research livestock that can be lost due to the surgical implantation of a ruminal cannula.

  15. Flue gas conditioning for improved particle collection in electrostatic precipitators. First topical report, Results of laboratory screening of additives

    SciTech Connect

    Durham, M.D.

    1993-04-16

    Several tasks have been completed in a program to evaluate additives to improve fine particle collection in electrostatic precipitators. Screening tests and laboratory evaluations of additives are summarized in this report. Over 20 additives were evaluated; four were found to improve flyash precipitation rates. The Insitec particle analyzer was also evaluated; test results show that the analyzer will provide accurate sizing and counting information for particles in the size range of {le} 10 {mu}m dia.

  16. Starting a European Space Agency Sample Analogue Collection for Robotic Exploration Missions

    NASA Astrophysics Data System (ADS)

    Smith, C. L.; Mavris, C.; Michalski, J. R.; Rumsey, M. S.; Russell, S. S.; Jones, C.; Schroeven-Deceuninck, H.

    2015-12-01

    The Natural History Museum is working closely with the European Space Agency (ESA) and the UK Space Agency to develop a European collection of analogue materials with appropriate physical/mechanical and chemical (mineralogical) properties which can support the development and verification of both spacecraft and scientific systems for potential science and exploration missions to Phobos/Deimos, Mars, C-type asteroids and the Moon. As an ESA Collection it will be housed at the ESA Centre based at Harwell, UK. The "ESA Sample Analogues Collection" will be composed of both natural and artificial materials chosen to (as closely as possible) replicate the surfaces and near-surfaces of different Solar System target bodies of exploration interest. The analogue samples will be fully characterised in terms of both their physical/mechanical properties (compressive strength, bulk density, grain shape, grain size, cohesion and angle of internal friction) and their chemical/mineralogical properties (texture, modal mineralogy, bulk chemical composition - major, minor and trace elements and individual mineralogical compositions). The Collection will be fully curated to international standards including implementation of a user-friendly database and will be available for use by engineers and scientists across the UK and Europe. Enhancement of the initial Collection will be possible through collaborations with other ESA and UK Space Agency supported activities, such as the acquisition of new samples during field trials.

  17. Starting a European Space Agency Sample Analogue Collection for Robotic Exploration Missions

    NASA Astrophysics Data System (ADS)

    Sherwood Lollar, B.; Sutcliffe, C. N.; Ballentine, C. J.; Onstott, T. C.; Lau, C. Y. M.; Magnabosco, C.; Slater, G.; Moser, D. P.

    2014-12-01

    The Natural History Museum is working closely with the European Space Agency (ESA) and the UK Space Agency to develop a European collection of analogue materials with appropriate physical/mechanical and chemical (mineralogical) properties which can support the development and verification of both spacecraft and scientific systems for potential science and exploration missions to Phobos/Deimos, Mars, C-type asteroids and the Moon. As an ESA Collection it will be housed at the ESA Centre based at Harwell, UK. The "ESA Sample Analogues Collection" will be composed of both natural and artificial materials chosen to (as closely as possible) replicate the surfaces and near-surfaces of different Solar System target bodies of exploration interest. The analogue samples will be fully characterised in terms of both their physical/mechanical properties (compressive strength, bulk density, grain shape, grain size, cohesion and angle of internal friction) and their chemical/mineralogical properties (texture, modal mineralogy, bulk chemical composition - major, minor and trace elements and individual mineralogical compositions). The Collection will be fully curated to international standards including implementation of a user-friendly database and will be available for use by engineers and scientists across the UK and Europe. Enhancement of the initial Collection will be possible through collaborations with other ESA and UK Space Agency supported activities, such as the acquisition of new samples during field trials.

  18. College Students' Perceptions of Collective Efficacy: Results from a Nonurban Sample

    ERIC Educational Resources Information Center

    Domoff, Sarah E.; Hayman, Jennifer; Tompsett, Carolyn J.

    2012-01-01

    Although the relationship between neighborhood characteristics and collective efficacy is well established in urban populations with community samples, it is unclear if this relationship holds in rural areas. The current study fills this gap by assessing the perceptions of adolescents from nonurban areas to examine the relationships between…

  19. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN USING GAUZE FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure, urine samples are often needed to analyze pesticide metabolites. However, this is difficult for children wearing diapers because simple and feasible techniques suitable for field collection are not available. The objectives of this study were to te...

  20. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN USING COTTON GAUZE FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure, urine samples are often needed to analyze pesticide metabolites. However, this is difficult for children wearing diapers because simple and feasible techniques suitable for field collection are not available. The objectives of this study were to t...

  1. The GENESIS Mission Solar Wind Samples: Collection Times, Estimated Fluences, and Solar-Wind Conditions

    NASA Astrophysics Data System (ADS)

    Reisenfeld, D. B.; Wiens, R. C.; Barraclough, B. L.; Steinberg, J. E.; Dekoning, C.; Zurbuchen, T. H.; Burnett, D. S.

    2005-03-01

    We have correlated the GENESIS sample collection times for the different solar-wind regimes with compositional data from GENESIS/GIM and ACE/SWICS instruments. We discuss GENESIS regime selection and new results in solar-wind elemental fractionation.

  2. Astronauts Young and Duke collect rock samples along simulated lunar traverse

    NASA Technical Reports Server (NTRS)

    1971-01-01

    Astronauts John W. Young, left, prime crew commander for Apollo 16, and Charles M. Duke Jr., lunar module pilot, collect rock samples along a simulated lunar traverse route in the Coso Hills, near Ridgecrest, California. Astronaut Eugene A. Cernan, right background, prime crew commander for Apollo 17, looks on. The astronauts trained at the U.S. Naval Ordnance Test Station.

  3. 77 FR 51818 - Agency Information Collection Activities; Application and Approval To Manipulate, Examine, Sample...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-27

    ..., Office of Management and Budget. Comments should be addressed to the OMB Desk Officer for U.S. Customs... SECURITY U.S. Customs and Border Protection Agency Information Collection Activities; Application and Approval To Manipulate, Examine, Sample, or Transfer Goods AGENCY: U.S. Customs and Border...

  4. Collecting Stream Samples for Water Quality. Module 16. Vocational Education Training in Environmental Health Sciences.

    ERIC Educational Resources Information Center

    Consumer Dynamics Inc., Rockville, MD.

    This module, one of 25 on vocational education training for careers in environmental health occupations, contains self-instructional materials on collecting stream samples for water quality. Following guidelines for students and instructors and an introduction that explains what the student will learn are three lessons: (1) using a job aid to…

  5. 21 CFR 111.80 - What representative samples must you collect?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What representative samples must you collect? 111.80 Section 111.80 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION CURRENT GOOD MANUFACTURING PRACTICE IN...

  6. Collective Socialization and Child Conduct Problems: A Multilevel Analysis with an African American Sample

    ERIC Educational Resources Information Center

    Simons, Leslie Gordon; Simons, Ronald L.; Conger, Rand D.; Brody, Gene H.

    2004-01-01

    This article uses hierarchical linear modeling with a sample of African American children and their primary caregivers to examine the association between various community factors and child conduct problems. The analysis revealed a rather strong inverse association between level of collective socialization and conduct problems. This relationship…

  7. 78 FR 25308 - Proposed Collection; Comment Request; Coal Mine Dust Sampling Devices

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-30

    ... Safety and Health Administration Proposed Collection; Comment Request; Coal Mine Dust Sampling Devices...) determine the concentration of respirable dust in coal mines. CPDMs must be designed and constructed for coal miners to wear and operate without impeding their ability to perform their work safely...

  8. Use of aspiration method for collecting brain samples for rabies diagnosis in small wild animals.

    PubMed

    Iamamoto, K; Quadros, J; Queiroz, L H

    2011-02-01

    In developing countries such as Brazil, where canine rabies is still a considerable problem, samples from wildlife species are infrequently collected and submitted for screening for rabies. A collaborative study was established involving environmental biologists and veterinarians for rabies epidemiological research in a specific ecological area located at the Sao Paulo State, Brazil. The wild animals' brains are required to be collected without skull damage because the skull's measurements are important in the identification of the captured animal species. For this purpose, samples from bats and small mammals were collected using an aspiration method by inserting a plastic pipette into the brain through the magnum foramen. While there is a progressive increase in the use of the plastic pipette technique in various studies undertaken, it is also appreciated that this method could foster collaborative research between wildlife scientists and rabies epidemiologists thus improving rabies surveillance.

  9. New additions to the National Plant Germplasm System’s Beta collection: Southern Morocco expedition

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The USDA Agricultural Research Service’s National Plant Germplasm System’s (NPGS) Beta collection is comprised of 2,541 accessions from 14 species. The largest number of accessions is from Beta vulgaris ssp. vulgaris, (domesticated beet crops – table, leaf (Swiss chard), fodder and, primarily, sugar...

  10. 76 FR 24854 - Proposed Information Collection; Comment Request; Additional Protocol Report Forms

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-03

    ... of the U.S. commercial nuclear fuel cycle, including: Mining and milling of nuclear materials... locations where these activities occur in order to verify the data on the form. II. Method of Collection Submitted electronically or paper format. III. Data OMB Control Number: 0694-0135. Form Number(s): AP-A,...

  11. Prospective Collection of Tissue Samples at Autopsy in Children with Diffuse Intrinsic Pontine Glioma

    PubMed Central

    Broniscer, Alberto; Baker, Justin N.; Baker, Suzanne J.; Chi, Susan N.; Geyer, J. Russell; Morris, E. Brannon; Gajjar, Amar

    2010-01-01

    BACKGROUND Brain tissue obtained at autopsy has been used in research for non-oncological disorders. However, this tool has never been systematically used in large investigational studies for cancer. We conducted a prospective, multicenter study to assess the feasibility of tissue collection at autopsy and its suitability for molecular analyses in children with diffuse intrinsic pontine glioma. METHODS Tumor tissue was collected at diagnosis, if clinically indicated, or at autopsy. Normal brain tissue was also collected at autopsy. The integrity of DNA and RNA was evaluated in all samples. Logistical data about autopsies were recorded. The feasibility of tissue collection at autopsy was assessed for patients treated at a single institution over a 43-month period. RESULTS Tumor samples were collected at diagnosis (n=3) or at autopsy (n=38) at 29 centers across the US; samples were obtained at diagnosis and autopsy in two cases. The median interval from death to autopsy was 7.7 hours. DNA and RNA with minimal or partial degradation, which were suitable for genome-wide analysis, were obtained from 100% and 63% of tumor samples, respectively. At the coordinating institution, approximately 40% of parents consented to autopsy and 40% declined. During the study period, 12 autopsies were obtained from patients who did not receive therapy at the coordinating center. CONCLUSIONS Multicenter, biological studies based on tissue obtained at autopsy are feasible in children with brain cancer. Our experience established a new paradigm for brain tissue collection which may increase the potential for research studies in patients with cancer. PMID:20589749

  12. Salmonella Prevalence and Antimicrobial Susceptibility Among Dairy Farm Environmental Samples Collected in Texas.

    PubMed

    Rodriguez-Rivera, Lorraine D; Cummings, Kevin J; Loneragan, Guy H; Rankin, Shelley C; Hanson, Devin L; Leone, William M; Edrington, Thomas S

    2016-04-01

    Dairy cattle are a reservoir of several Salmonella serovars that are leading causes of human salmonellosis. The objectives of this study were to estimate the environmental prevalence of Salmonella on dairy farms in Texas and to characterize the antimicrobial susceptibility of the isolates. Eleven dairy farms throughout Texas were sampled from August through October 2013, using a cross-sectional approach. Samples were collected from four locations within each farm (hospital pen, maternity pen, cow housing area, and calf housing area), and feces were collected from cull cows as available. Environmental and fecal samples were processed for Salmonella, and isolates were tested for susceptibility to 15 antimicrobial agents. Serovar characterization was performed on a subset of these isolates. Salmonella was isolated from 67.0% (236/352) of the environmental samples and 64.2% (43/67) of the cull cow fecal samples. Environmental samples from the maternity pen were significantly more likely to be Salmonella positive than samples from the cow and calf housing areas. Multidrug resistance was evident in 11.9% (27/226) of environmental isolates and 19.5% (8/41) of fecal isolates. Salmonella isolates from the calf housing area and maternity pen were significantly more likely to be multidrug resistant (MDR) than isolates from the cow housing area. The most common serovars found among the MDR isolates were Newport, Muenchen, and Typhimurium. These results help provide a focus for efforts to mitigate the burden of antimicrobial-resistant Salmonella at the preharvest level.

  13. PIXE Analysis of Aerosol and Soil Samples Collected in the Adirondack Mountains

    NASA Astrophysics Data System (ADS)

    Yoskowitz, Joshua; Ali, Salina; Nadareski, Benjamin; Labrake, Scott; Vineyard, Michael

    2014-09-01

    We have performed an elemental analysis of aerosol and soil samples collected at Piseco Lake in Upstate New York using proton induced X-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the aerosol samples near Piseco Lake and distribute the particulate matter onto Kapton foils by particle size. The soil samples were also collected at Piseco Lake and pressed into cylindrical pellets for experimentation. PIXE analysis of the aerosol and soil samples were performed with 2.2-MeV proton beams from the 1.1-MV Pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. There are higher concentrations of sulfur at smaller particle sizes (0.25-1 μm), suggesting that it could be suspended in the air for days and originate from sources very far away. Other elements with significant concentrations peak at larger particle sizes (1-4 μm) and are found in the soil samples, suggesting that these elements could originate in the soil. The PIXE analysis will be described and the resulting data will be presented.

  14. Toward Lower Organic Environments in Astromaterial Sample Curation for Diverse Collections

    NASA Technical Reports Server (NTRS)

    Allton, J. H.; Allen, C. C.; Burkett, P. J.; Calaway, M. J.; Oehler, D. Z.

    2012-01-01

    Great interest was taken during the frenzied pace of the Apollo lunar sample return to achieve and monitor organic cleanliness. Yet, the first mission resulted in higher organic contamination to samples than desired. But improvements were accomplished by Apollo 12 [1]. Quarantine complicated the goal of achieving organic cleanliness by requiring negative pressure glovebox containment environments, proximity of animal, plant and microbial organic sources, and use of organic sterilants in protocols. A special low organic laboratory was set up at University of California Berkeley (UCB) to cleanly subdivide a subset of samples [2, 3, 4]. Nevertheless, the basic approach of handling rocks and regolith inside of a positive pressure stainless steel glovebox and restrict-ing the tool and container materials allowed in the gloveboxes was established by the last Apollo sample re-turn. In the last 40 years, the collections have grown to encompass Antarctic meteorites, Cosmic Dust, Genesis solar wind, Stardust comet grains and Hayabusa asteroid grains. Each of these collections have unique curation requirements for organic contamination monitor-ing and control. Here is described some changes allowed by improved technology or driven by changes in environmental regulations and economy, concluding with comments on organic witness wafers. Future sample return missions (OSIRIS-Rex; Mars; comets) will require extremely low levels of organic contamination in spacecraft collection and thus similarly low levels in curation. JSC Curation is undertaking a program to document organic baseline levels in current operations and devise ways to reduce those levels.

  15. Comparison of blood chemistry values for samples collected from juvenile chinook salmon by three methods

    USGS Publications Warehouse

    Congleton, J.L.; LaVoie, W.J.

    2001-01-01

    Thirteen blood chemistry indices were compared for samples collected by three commonly used methods: caudal transection, heart puncture, and caudal vessel puncture. Apparent biases in blood chemistry values for samples obtained by caudal transection were consistent with dilution with tissue fluids: alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), creatine kinase (CK), triglyceride, and K+ were increased and Na+ and Cl- were decreased relative to values for samples obtained by caudal vessel puncture. Some enzyme activities (ALT, AST, LDH) and K+ concentrations were also greater in samples taken by heart puncture than in samples taken by caudal vessel puncture. Of the methods tested, caudal vessel puncture had the least effect on blood chemistry values and should be preferred for blood chemistry studies on juvenile salmonids.

  16. Improved explosive collection and detection with rationally assembled surface sampling materials

    SciTech Connect

    Chouyyok, Wilaiwan; Bays, J. Timothy; Gerasimenko, Aleksandr A.; Cinson, Anthony D.; Ewing, Robert G.; Atkinson, David A.; Addleman, R. Shane

    2016-01-01

    Sampling and detection of trace explosives is a key analytical process in modern transportation safety. In this work we have explored some of the fundamental analytical processes for collection and detection of trace level explosive on surfaces with the most widely utilized system, thermal desorption IMS. The performance of the standard muslin swipe material was compared with chemically modified fiberglass cloth. The fiberglass surface was modified to include phenyl functional groups. When compared to standard muslin, the phenyl functionalized fiberglass sampling material showed better analyte release from the sampling material as well as improved response and repeatability from multiple uses of the same swipe. The improved sample release of the functionalized fiberglass swipes resulted in a significant increase in sensitivity. Various physical and chemical properties were systematically explored to determine optimal performance. The results herein have relevance to improving the detection of other explosive compounds and potentially to a wide range of other chemical sampling and field detection challenges.

  17. Measured phenol concentrations in air and rain water samples collected near a wood preserving facility

    SciTech Connect

    Allen, S.K.; Allen, C.W.

    1995-12-31

    Phenol concentrations were determined in air and rain water samples collected downwind from a coal tar creosote wood preserving facility in Terre Haute, IN. Coal tar creosote is known to contain a large number of constituents and is composed chiefly of polycyclic aromatic hydrocarbons (PAH), phenols, and N-, S-, and O-heterocycles. Phenol was chosen as a marker compound for coal tar creosote emissions because it is present at a large mole fraction in coal tar creosote. Phenol was determined by HPLC with UV-Visible detection. Phenol in collected rain water samples was determined directly by HPLC after acidification and filtration. Phenol concentrations in collected air samples ranged from 4.1 to 15.7 {micro}g/m3 while rain water concentrations ranged from 7.9 to 28.2 {micro}g/L. Using a value for the thermodynamic Henry`s law constant of K{sub H} = 4.5 {times} 10{sup {minus}4} L atm/mole at 20 C for phenol and measured gas-phase phenol concentrations, even higher rain water concentrations would be expected if equilibrium was established. This indicates that the amount of phenol present in the air parcels sampled exceeded the amount that could be scavenged by rain drops under the conditions prevailing at the time of sampling. The values for phenol concentrations reported here are roughly two orders of magnitude higher than results from previous studies where phenol concentrations in air and rain water samples collected in urban areas were reported. It is likely that other more toxic constituents of coal tar creosote are also present at high concentrations in air parcels that receive emissions from wood treatment facilities.

  18. Determination of multiple toxins in whelk and clam samples collected from the Chukchi and Bering seas.

    PubMed

    Li, Aifeng; Chen, Huidan; Qiu, Jiangbing; Lin, Heshan; Gu, Haifeng

    2016-01-01

    Buccinidae whelk Neptunea varicifera (Dall), Cardiidae clam Serripes laperousii (Deshayes), and two unknown species of whelk and clam were collected from the Arctic Chukchi Sea and sub-Arctic Bering Sea in July 2014. In this study, the mollusk samples were analyzed by different liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS) methods for multiple shellfish toxins, including okadaic acid (OA), pectenotoxin (PTX), yessotoxin (YTX), azaspiracid (AZA), cyclic imines (CI), and saxitoxin (STX) groups. PTX2 (≈2.0 μg kg(-1) whole tissues) was detected exclusively in the clam S. laperousii collected from the Chukchi Sea. OA and dinophysistoxin-1 (DTX1) were restricted to mollusk samples collected from the Bering Sea, and OA was the dominant component of the whelk N. varicifera (63 μg kg(-1) digestive gland) and an unknown species of whelk (6.8 μg kg(-1) digestive gland). Spirolide-1 (SPX1) was confirmed in most samples except for the whelk N. varicifera collected from the Bering Sea. The highest content of SPX1 (≈18.5 μg kg(-1) digestive gland) occurred in the whelk N. varicifera collected from the Chukchi Sea, along with the suspected presence of SPX-C, SPX-D and didesMe-SPX-C. YTX, as well as its derivatives 45-OH-YTX and 45,46,47-Trinor-YTX, were found in all samples, with the highest YTX content (66 μg kg(-1) digestive gland) present in the whelk N. varicifera collected from the Chukchi Sea. Interestingly, STX and dcSTX were measured only in the whelk N. varicifera and unknown species of clam collected from the Chukchi Sea. No AZA-group toxins, gymnodimine (GYM), or pinnatoxin G were found in any samples analyzed. Results demonstrated that the mollusk samples were contaminated by multiple shellfish toxins in the Chukchi and Bering seas. This study highlights the need to monitor potentially toxic microalgae in the Arctic and sub-Arctic regions, as well as species of mollusk that may be included in future commercial or

  19. Optimizing detection of noble gas emission at a former UNE site: sample strategy, collection, and analysis

    NASA Astrophysics Data System (ADS)

    Kirkham, R.; Olsen, K.; Hayes, J. C.; Emer, D. F.

    2013-12-01

    Underground nuclear tests may be first detected by seismic or air samplers operated by the CTBTO (Comprehensive Nuclear-Test-Ban Treaty Organization). After initial detection of a suspicious event, member nations may call for an On-Site Inspection (OSI) that in part, will sample for localized releases of radioactive noble gases and particles. Although much of the commercially available equipment and methods used for surface and subsurface environmental sampling of gases can be used for an OSI scenario, on-site sampling conditions, required sampling volumes and establishment of background concentrations of noble gases require development of specialized methodologies. To facilitate development of sampling equipment and methodologies that address OSI sampling volume and detection objectives, and to collect information required for model development, a field test site was created at a former underground nuclear explosion site located in welded volcanic tuff. A mixture of SF-6, Xe127 and Ar37 was metered into 4400 m3 of air as it was injected into the top region of the UNE cavity. These tracers were expected to move towards the surface primarily in response to barometric pumping or through delayed cavity pressurization (accelerated transport to minimize source decay time). Sampling approaches compared during the field exercise included sampling at the soil surface, inside surface fractures, and at soil vapor extraction points at depths down to 2 m. Effectiveness of various sampling approaches and the results of tracer gas measurements will be presented.

  20. Transient thermal envelope for rovers and sample collecting devices on the Moon

    NASA Astrophysics Data System (ADS)

    Hager, P. B.; Parzinger, S.; Haarmann, R.; Walter, U.

    2015-03-01

    The requirements for the design of rovers and sample collecting devices for the Moon are driven by the harsh and diverse thermal lunar environment. Local lunar surface temperatures are governed by boulders and craters. The present work quantifies the changes in solar and infrared heat fluxes q˙Sol and q˙IR impinging on a rover or a sample collecting device, on the surface of the Moon, by combining lunar surface models, spacecraft and manipulator models, and transient thermal calculations. The interaction between a rover, boulders, and craters was simulated for three solar elevation angles (θ = 2°, 10°, and 90°), resembling lunar surface temperatures of Treg = 170, 248, and 392 K, respectively. Infrared and solar heat fluxes for paths in the vicinity of a single boulder, a field of five boulders, and a single crater were compared to a path on an unobstructed surface. The same heat fluxes were applied to closed and open sample collecting devices to investigate the temperature development of the transported regolith sample. The results show how total received infrared heat on a rover may increase by up to 331%, over the course of a transit in front of sunlit boulders compared to the same transit over an unobstructed plane. Temporary this leads to a 12-fold increased infrared heat flux at closest distance to the obstacle. A transit through a small bowl shaped crater on the other hand may decrease total received solar heat by as much as 86%. Relative as well as absolute influence of surface features on received heat fluxes increases significantly towards smaller solar elevation angles. The temperature of pristine samples, transported in closed or open sample collecting devices, increase from 120 to 150 K within 1 to 1.3 h if exposed to direct solar illumination and infrared heat. Protection from solar illumination yields in 8-fold and 5-fold increased transport times for closed and open sample devices, respectively. Closed sample transporters dampen short exposure

  1. Macroinvertebrate and algal community sample collection methods and data collected at selected sites in the Eagle River watershed, Colorado, 2000-07

    USGS Publications Warehouse

    Zuellig, Robert E.; Bruce, James F.

    2010-01-01

    State and local agencies are concerned about the effects of increasing urban development and human population growth on water quality and the biological condition of regional streams in the Eagle River watershed. In response to these needs, the U.S. Geological Survey initiated a study in cooperation with the Colorado River Water Conservation District, Eagle County, Eagle River Water and Sanitation District, Upper Eagle Regional Water Authority, Colorado Department of Transportation, City of Aurora, Town of Eagle, Town of Gypsum, Town of Minturn, Town of Vail, Vail Resorts, Colorado Springs Utilities, Denver Water, and the U.S. Department of Agriculture Forest Service. As part of this study, previously collected macroinvertebrate and algal data from the Eagle River watershed were compiled. This report includes macroinvertebrate data collected by the U.S. Geological Survey and(or) the U.S. Department of Agriculture Forest Service from 73 sites from 2000 to 2007 and algal data collected from up to 26 sites between 2000 and 2001 in the Eagle River watershed. Additionally, a brief description of the sample collection methods and data processing procedures are presented.

  2. Aerosol Sampling System for Collection of Capstone Depleted Uranium Particles in a High-Energy Environment

    SciTech Connect

    Holmes, Thomas D.; Guilmette, Raymond A.; Cheng, Yung-Sung; Parkhurst, MaryAnn; Hoover, Mark D.

    2009-03-01

    The Capstone Depleted Uranium Aerosol Study was undertaken to obtain aerosol samples resulting from a kinetic-energy cartridge with a large-caliber depleted uranium (DU) penetrator striking an Abrams or Bradley test vehicle. The sampling strategy was designed to (1) optimize the performance of the samplers and maintain their integrity in the extreme environment created during perforation of an armored vehicle by a DU penetrator, (2) collect aerosols as a function of time post-impact, and (3) obtain size-classified samples for analysis of chemical composition, particle morphology, and solubility in lung fluid. This paper describes the experimental setup and sampling methodologies used to achieve these objectives. Custom-designed arrays of sampling heads were secured to the inside of the target in locations approximating the breathing zones of the vehicle commander, loader, gunner, and driver. Each array was designed to support nine filter cassettes and nine cascade impactors mounted with quick-disconnect fittings. Shielding and sampler placement strategies were used to minimize sampler loss caused by the penetrator impact and the resulting fragments of eroded penetrator and perforated armor. A cyclone train was used to collect larger quantities of DU aerosol for chemical composition and solubility. A moving filter sample was used to obtain semicontinuous samples for depleted uranium concentration determination. Control for the air samplers was provided by five remotely located valve control and pressure monitoring units located inside and around the test vehicle. These units were connected to a computer interface chassis and controlled using a customized LabVIEW engineering computer control program. The aerosol sampling arrays and control systems for the Capstone study provided the needed aerosol samples for physicochemical analysis, and the resultant data were used for risk assessment of exposure to DU aerosol.

  3. Aerosol sampling system for collection of Capstone depleted uranium particles in a high-energy environment.

    PubMed

    Holmes, Thomas D; Guilmette, Raymond A; Cheng, Yung Sung; Parkhurst, Mary Ann; Hoover, Mark D

    2009-03-01

    The Capstone Depleted Uranium (DU) Aerosol Study was undertaken to obtain aerosol samples resulting from a large-caliber DU penetrator striking an Abrams or Bradley test vehicle. The sampling strategy was designed to (1) optimize the performance of the samplers and maintain their integrity in the extreme environment created during perforation of an armored vehicle by a DU penetrator, (2) collect aerosols as a function of time post perforation, and (3) obtain size-classified samples for analysis of chemical composition, particle morphology, and solubility in lung fluid. This paper describes the experimental setup and sampling methodologies used to achieve these objectives. Custom-designed arrays of sampling heads were secured to the inside of the target in locations approximating the breathing zones of the crew locations in the test vehicles. Each array was designed to support nine filter cassettes and nine cascade impactors mounted with quick-disconnect fittings. Shielding and sampler placement strategies were used to minimize sampler loss caused by the penetrator impact and the resulting fragments of eroded penetrator and perforated armor. A cyclone train was used to collect larger quantities of DU aerosol for measurement of chemical composition and solubility. A moving filter sample was used to obtain semicontinuous samples for DU concentration determination. Control for the air samplers was provided by five remotely located valve control and pressure monitoring units located inside and around the test vehicle. These units were connected to a computer interface chassis and controlled using a customized LabVIEW engineering computer control program. The aerosol sampling arrays and control systems for the Capstone study provided the needed aerosol samples for physicochemical analysis, and the resultant data were used for risk assessment of exposure to DU aerosol.

  4. Chemical analyses of soil samples collected from the Sandia National Laboratories/NM, Tonopah Test Range environs, 1994-2005.

    SciTech Connect

    Deola, Regina Anne; Oldewage, Hans D.; Herrera, Heidi M.; Miller, Mark Laverne

    2006-05-01

    From 1994 through 2005, the Environmental Management Department of Sandia National Laboratories (SNL) at the Tonopah Test Range (TTR), NV, has collected soil samples at numerous locations on-site, on the perimeter, and off-site for the purpose of determining potential impacts to the environs from operations at TTR. These samples were submitted to an analytical laboratory of metal-in-soil analyses. Intercomparisons of these results were then made to determine if there was any statistical difference between on-site, perimeter, and off-site samples, or if there were increasing or decreasing trends which indicated that further investigation may be warranted. This work provided the SNL Environmental Management Department with a sound baseline data reference against which to compare future operational impacts. In addition, it demonstrates the commitment that the Laboratories have to go beyond mere compliance to achieve excellence in its operations. This data is presented in graphical format with narrative commentaries on particular items of interest.

  5. Salivary cortisol results obtainable within minutes of sample collection correspond with traditional immunoassays

    PubMed Central

    Shirtcliff, E.A.; Buck, R.L.; Laughlin, M.; Hart, T.; Cole, C.R.; Slowey, P.D.

    2015-01-01

    Purpose Cortisol is frequently assayed as a stress-responsive biomarker which changes over the course of minutes to meet the demands of an individual’s social context. Salivary cortisol is often utilized as a non-invasive sampling methodology which possesses important health implications. A critical barrier to psychobiological research involving salivary cortisol is a time-delay of days to months before cortisol results are obtained via immunoassay, long after the individual is no longer proximate to the social context in which they provided the sample. The current study was designed to address this critical barrier through creation of a lateral flow technology (LFT) cortisol device capable of measuring salivary cortisol within minutes of sample collection. LFT is frequently used within commercial point-of-care settings to obtain rapid answers to the presence/absence of a biomarker. The present study extends LFT into the research domain by presenting performance characteristics of a quantitative LFT which measures salivary cortisol within 20 minutes of sample collection. Methods Saliva samples on N=29 adults (15 males) were obtained in the morning and afternoon using Passive Drool and then the Super•SAL™ Extra Collection Device (hereafter Super•SAL™) and later assayed with LFT and a commercially available enzyme-immunoassay. Findings Results show LFT correlated well with these collection methods (R=.872 with Super•SAL™; R=.739 with Passive Drool, p-values<.0001) and at comparable levels to correspondence of Super•SAL™ with Passive Drool (R=.798, p<.0001) which were measured with the same assay. Implications These results open up an exciting new possibility to integrate this technological advance into stress research, including knowing and potentially changing the individual’s social context in a time-sensitive manner. Methodological improvements such as this have the possibility of refining conceptual models of stress reactivity and regulation

  6. Curating NASA's future extraterrestrial sample collections: How do we achieve maximum proficiency?

    NASA Astrophysics Data System (ADS)

    McCubbin, Francis; Evans, Cynthia; Allton, Judith; Fries, Marc; Righter, Kevin; Zolensky, Michael; Zeigler, Ryan

    2016-07-01

    Introduction: The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10E "Curation of Extraterrestrial Materials", JSC is charged with "The curation of all extraterrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "…documentation, preservation, preparation, and distribution of samples for research, education, and public outreach." Here we describe some of the ongoing efforts to ensure that the future activities of the NASA Curation Office are working to-wards a state of maximum proficiency. Founding Principle: Curatorial activities began at JSC (Manned Spacecraft Center before 1973) as soon as design and construction planning for the Lunar Receiving Laboratory (LRL) began in 1964 [1], not with the return of the Apollo samples in 1969, nor with the completion of the LRL in 1967. This practice has since proven that curation begins as soon as a sample return mission is conceived, and this founding principle continues to return dividends today [e.g., 2]. The Next Decade: Part of the curation process is planning for the future, and we refer to these planning efforts as "advanced curation" [3]. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of collections as envisioned by NASA exploration goals. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, curation of organically- and biologically-sensitive samples, and the use of minimally invasive analytical techniques (e.g., micro-CT, [4]) to characterize samples. These efforts will be useful for Mars Sample Return

  7. 49 CFR 199.111 - Retention of samples and additional testing.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... request, the sample may be discarded following the end of the 365-day period. (b) If the medical review officer (MRO) determines there is no legitimate medical explanation for a confirmed positive test result... and Human Services. The operator may require the employee to pay in advance the cost of shipment...

  8. The U.S. Geological Survey Geologic Collections Management System (GCMS)—A master catalog and collections management plan for U.S. Geological Survey geologic samples and sample collections

    USGS Publications Warehouse

    ,

    2015-01-01

    The general consideration for implementation of the GCMS is that all active USGS geologic sample repositories will form the core of GCMS and that participating science centers will develop procedures based on proposed GCMS methodologies. The GCMS is a collective resource for the entire USGS community and the users who discover the geologic materials kept in these repositories and seek to access them.

  9. Multiple Approaches to Down Sizing of the Lunar Sample Return Collection

    NASA Technical Reports Server (NTRS)

    Lofgren, Gary E.; Horz, F.

    2010-01-01

    Future Lunar missions are planned for at least 7 days, significantly longer than the 3 days of the later Apollo missions. The last of those missions, A-17, returned 111 kg of samples plus another 20 kg of containers. The current Constellation program requirements for return weight for science is 100 kg with the hope of raising that limit to near 250 kg including containers and other non-geological materials. The estimated return weight for rock and soil samples will, at best, be about 175 kg. One method proposed to accomplish down-sizing of the collection is the use of a Geo-Lab in the lunar habitat to complete a preliminary examination of selected samples and facilitate prioritizing the return samples.

  10. Hematological Assessment in Pet Guinea Pigs (Cavia porcellus): Blood Sample Collection and Blood Cell Identification.

    PubMed

    Zimmerman, Kurt; Moore, David M; Smith, Stephen A

    2015-09-01

    Pet guinea pigs are presented to veterinary clinics for routine care and treatment of clinical diseases. In addition to obtaining clinical history and exam findings, diagnostic testing may be required, including hematological assessments. This article describes common blood collection methods, including venipuncture sites, the volume of blood that can be safely collected, and handling of the blood. Hematological parameters for normal guinea pigs are provided for comparison with in-house or commercial test results. A description of the morphology of guinea pig leukocytes is provided to assist in performing a differential count.

  11. Hematological assessment in pet guinea pigs (Cavia porcellus): blood sample collection and blood cell identification.

    PubMed

    Zimmerman, Kurt; Moore, David M; Smith, Stephen A

    2015-01-01

    Pet guinea pigs are presented to veterinary clinics for routine care and treatment of clinical diseases. In addition to obtaining clinical history and exam findings, diagnostic testing may be required, including hematological assessments. This article describes common blood collection methods, including venipuncture sites, the volume of blood that can be safely collected, and handling of the blood. Hematological parameters for normal guinea pigs are provided for comparison with in-house or commercial test results. A description of the morphology of guinea pig leukocytes is provided to assist in performing a differential count.

  12. Microcontroller-based system for collecting anaerobic blood samples from a running greyhound.

    PubMed

    Schmalzried, R T; Toll, P W; Devore, J J; Fedde, M R

    1992-04-01

    Many physiological variables change rapidly in the blood during sprint exercise. To characterize the dynamics and extent of these changes, blood samples must be obtained during exercise. We describe herein a portable, microcontroller-based system used to automatically obtain repeated, anaerobic, arterial blood samples from greyhounds before, during, and following a race on a track. In addition, the system also records the blood temperature in the pulmonary artery each time a blood sample is taken. The system has been tested for more than 2 years and has proven to be reliable and effective.

  13. Efficient Genome-Wide Sequencing and Low-Coverage Pedigree Analysis from Noninvasively Collected Samples.

    PubMed

    Snyder-Mackler, Noah; Majoros, William H; Yuan, Michael L; Shaver, Amanda O; Gordon, Jacob B; Kopp, Gisela H; Schlebusch, Stephen A; Wall, Jeffrey D; Alberts, Susan C; Mukherjee, Sayan; Zhou, Xiang; Tung, Jenny

    2016-06-01

    Research on the genetics of natural populations was revolutionized in the 1990s by methods for genotyping noninvasively collected samples. However, these methods have remained largely unchanged for the past 20 years and lag far behind the genomics era. To close this gap, here we report an optimized laboratory protocol for genome-wide capture of endogenous DNA from noninvasively collected samples, coupled with a novel computational approach to reconstruct pedigree links from the resulting low-coverage data. We validated both methods using fecal samples from 62 wild baboons, including 48 from an independently constructed extended pedigree. We enriched fecal-derived DNA samples up to 40-fold for endogenous baboon DNA and reconstructed near-perfect pedigree relationships even with extremely low-coverage sequencing. We anticipate that these methods will be broadly applicable to the many research systems for which only noninvasive samples are available. The lab protocol and software ("WHODAD") are freely available at www.tung-lab.org/protocols-and-software.html and www.xzlab.org/software.html, respectively.

  14. Efficient Genome-Wide Sequencing and Low-Coverage Pedigree Analysis from Noninvasively Collected Samples

    PubMed Central

    Snyder-Mackler, Noah; Majoros, William H.; Yuan, Michael L.; Shaver, Amanda O.; Gordon, Jacob B.; Kopp, Gisela H.; Schlebusch, Stephen A.; Wall, Jeffrey D.; Alberts, Susan C.; Mukherjee, Sayan; Zhou, Xiang; Tung, Jenny

    2016-01-01

    Research on the genetics of natural populations was revolutionized in the 1990s by methods for genotyping noninvasively collected samples. However, these methods have remained largely unchanged for the past 20 years and lag far behind the genomics era. To close this gap, here we report an optimized laboratory protocol for genome-wide capture of endogenous DNA from noninvasively collected samples, coupled with a novel computational approach to reconstruct pedigree links from the resulting low-coverage data. We validated both methods using fecal samples from 62 wild baboons, including 48 from an independently constructed extended pedigree. We enriched fecal-derived DNA samples up to 40-fold for endogenous baboon DNA and reconstructed near-perfect pedigree relationships even with extremely low-coverage sequencing. We anticipate that these methods will be broadly applicable to the many research systems for which only noninvasive samples are available. The lab protocol and software (“WHODAD”) are freely available at www.tung-lab.org/protocols-and-software.html and www.xzlab.org/software.html, respectively. PMID:27098910

  15. Potential contamination of forensic entomology samples collected in the mortuary: a case report.

    PubMed

    Archer, M S; Ranson, D L

    2005-01-01

    Carrion insects originating from infested bodies may establish small mortuary populations. Two Victorian Institute of Forensic Medicine cases are presented to illustrate how these insects can potentially contaminate forensic entomology samples collected in the mortuary. The first case proves that bodies can be colonised in the mortuary: when a decomposed body in freezer storage was thawed for a procedure in the main mortuary, it was colonised within five minutes of exposure by the beetle Necrobia rufipes De Geer (Cleridae, Coleoptera). The second case illustrates that immobile juvenile insects can be transferred between bodies, and describes the transfer of an Eristalis sp. (Syrphidae, Diptera) pupa from a decomposed to a fresh body. While the contamination risk is slight, it can be further minimised by checking mortuary-collected samples against those taken from the body discovery site, by mortuary pest control, and by checking previous mortuary admittance records for possible contamination sources.

  16. Enhanced Conformational Sampling Using Replica Exchange with Collective-Variable Tempering

    PubMed Central

    2015-01-01

    The computational study of conformational transitions in RNA and proteins with atomistic molecular dynamics often requires suitable enhanced sampling techniques. We here introduce a novel method where concurrent metadynamics are integrated in a Hamiltonian replica-exchange scheme. The ladder of replicas is built with different strengths of the bias potential exploiting the tunability of well-tempered metadynamics. Using this method, free-energy barriers of individual collective variables are significantly reduced compared with simple force-field scaling. The introduced methodology is flexible and allows adaptive bias potentials to be self-consistently constructed for a large number of simple collective variables, such as distances and dihedral angles. The method is tested on alanine dipeptide and applied to the difficult problem of conformational sampling in a tetranucleotide. PMID:25838811

  17. STS-55 Payload Specialist Schlegel collects fungi sample at SL-D2 Rack 1

    NASA Technical Reports Server (NTRS)

    1993-01-01

    STS-55 German Payload Specialist 2 Hans Schlegel, wearing lightweight headset, collects fungi sample while working at Spacelab Deutsche 2 (SL-D2) science module Rack 1 Work Bench. Schlegel is conducting these procedures in conjunction with the 'Fruiting Body Development of Fungi' experiment. Pieces of the experiment casing freefloat in the workstation.Schlegel represents the German Aerospace Research Establishment (DLR) on the 10-day spacelab mission.

  18. STS-55 Payload Specialist Schlegel collects fungi sample at SL-D2 Rack 1

    NASA Technical Reports Server (NTRS)

    1993-01-01

    STS-55 German Payload Specialist 2 Hans Schlegel, wearing lightweight headset, collects fungi sample while working at Spacelab Deutsche 2 (SL-D2) science module Rack 1 Work Bench. Schlegel is conducting these procedures in conjunction with the 'Fruiting Body Development of Fungi' experiment. Schlegel was one of two payload specialists representing the German Aerospace Research Establishment (DLR) on the 10-day spacelab mission.

  19. LC-ESI-MS determination of diethylene glycol pollution in sea water samples collected around gas extraction platform plants.

    PubMed

    Cappiello, A; Famiglini, G; Palma, P; Termopoli, V; Trufelli, H; Di Mento, R; Mannozzi, M

    2009-11-15

    Produced formation waters (PFWs) represent the largest aqueous wastes that are normally discharged into the marine environment during the offshore gas production processes. The chemical additive diethylene glycol (DEG) is widely used in the gas production line and therefore can be found in the PFW, becoming of environmental concern. In this study, a new method has been developed for trace determination of DEG in sea water samples collected around offshore gas platforms. The method is based on liquid chromatography coupled to electrospray ionization mass spectrometry (LC-ESI-MS). Prior to analysis, water samples were derivatized using the Schotten-Baumann method for the benzoylation of glycols. The derivatization procedure allowed us to maximize the ESI-MS response of DEG and minimize the influence of interfering compounds. The method was validated and allowed a quantification of DEG in sea water samples with a method LOD of 0.4 ng/mL. The applicability of the procedure was demonstrated by analyzing sea water samples collected around eight gas platforms located in the Adriatic Sea (Italy).

  20. Tank 241-C-110 headspace gas and vapor characterization results for samples collected in August 1994

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  1. Tank 241-C-102 headspace gas and vapor characterization results for samples collected in August 1994

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  2. Tank 241-SX-103 headspace gas and vapor characterization results for samples collected in March 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  3. Tank 241-B-103 headspace gas and vapor characterization results for samples collected in February 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-27

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  4. Tank 241-U-103 headspace gas and vapor characterization results for samples collected in February 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-27

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  5. Tank 241-S-102 headspace gas and vapor characterization results for samples collected in March 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-26

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  6. Tank 241-U-105 headspace gas and vapor characterization results for samples collected in February 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  7. Tank 241-U-106 headspace gas and vapor characterization results for samples collected in March 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-26

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  8. Tank 241-S-111 headspace gas and vapor characterization results for samples collected in March 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  9. Tank 241-SX-106 headspace gas and vapor characterization results for samples collected in March 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  10. Urine concentrations of oral salbutamol in samples collected after intense exercise in endurance athletes.

    PubMed

    Hostrup, Morten; Kalsen, Anders; Auchenberg, Michael; Rzeppa, Sebastian; Hemmersbach, Peter; Bangsbo, Jens; Backer, Vibeke

    2014-06-01

    Our objective was to investigate urine concentrations of 8 mg oral salbutamol in samples collected after intense exercise in endurance athletes. Nine male endurance athletes with a VO2max of 70.2 ± 5.9 mL/min/kg (mean ± SD) took part in the study. Two hours after administration of 8 mg oral salbutamol, subjects performed submaximal exercise for 15 min followed by two, 2-min exercise bouts at an intensity corresponding to 110% of VO2max and a bout to exhaustion at same intensity. Urine samples were collected 4, 8, and 12 h following administration of salbutamol. Samples were analyzed by the Norwegian World Anti-doping Agency (WADA) laboratory. Adjustment of urine concentrations of salbutamol to a urine specific gravity (USG) of 1.020 g/mL was compared with no adjustment according to WADA's technical documents. We observed greater (P = 0.01) urine concentrations of salbutamol 4 h after administration when samples were adjusted to a USG of 1.020 g/mL compared with no adjustment (3089 ± 911 vs. 1918 ± 1081 ng/mL). With the current urine decision limit of 1200 ng/mL for salbutamol on WADA's 2013 list of prohibited substances, fewer false negative urine samples were observed when adjusted to a USG of 1.020 g/mL compared with no adjustment. In conclusion, adjustment of urine samples to a USG of 1.020 g/mL decreases risk of false negative doping tests after administration of oral salbutamol. Adjusting urine samples for USG might be useful when evaluating urine concentrations of salbutamol in doping cases.

  11. Determination of trace elements in volcanic rock samples collected from cenozoic lava eruption sites using LIBS.

    PubMed

    Gondal, Mohammed A; Nasr, Mohamed M; Ahmed, Zulfiqar; Yamani, Zain H

    2009-04-01

    Trace elements of environmental significance present in the volcanic rock samples collected from sites of the Cenozoic era flood basalt flows and eruptions were detected using locally developed laser-induced breakdown spectrometer. For spectro-chemical analysis of these samples, the plasma was generated by focusing a pulsed Nd: YAG laser radiation at 1064 nm wavelength on the target rock samples. These samples were collected from four widely separated locations surrounding the volcanic eruption sites belonging to the Harrat Hutaymah volcanic field in the vicinity of Taba town, situated to the east of Hail city of northern Saudi Arabia. These samples represent the scoria basalt lava flows as well as a large tuff-ring crater and it contains xenoliths. These flows occur widespread over the Earth's surface in this region, and their contained xenoliths are brought up from depths of a few tens of kilometers. This volcanic field has received much less attention in the previous geological studies; and consequently, its effects on the environment are not well defined. The concentration of different elements of environmental significance like Cr, Pb, Mn, Cd, Sr and other trace metals like Cu, Al, Ca, Mg, Zn, Ti and Fe in these rock samples were determined by spectral analysis. Parametric dependence for improvement of LIBS sensitivity for detection of these elements was also carried out. The highest concentration detected of environmentally significant elements like Cr, Mn, Pb, Sr and Ni are 1910, 1399, 90.5, 12412 and 461.5 ppm, respectively in four different lava samples which are considered to be much higher than the safe permissible limits. The LIBS results were compared with the results obtained using other analytical techniques such as the inductively coupled plasma atomic emission spectroscopy (ICP-AES).

  12. Microbeam Characterization of Corning Archeological Reference Glasses: New Additions to the Smithsonian Microbeam Standard Collection

    PubMed Central

    Vicenzi, Edward P.; Eggins, Stephen; Logan, Amelia; Wysoczanski, Richard

    2002-01-01

    An initial study of the minor element, trace element, and impurities in Corning archeological references glasses have been performed using three microbeam techniques: electron probe microanalysis (EPMA), laser ablation ICP-mass spectrometry (LA ICP-MS), and secondary ion mass spectrometry (SIMS). The EPMA results suggest a significant level of heterogeneity for a number of metals. Conversely, higher precision and a larger sampling volume analysis by LA ICP-MS indicates a high degree of chemical uniformity within all glasses, typically <2 % relative (1 σ). SIMS data reveal that small but measurable quantities of volatile impurities are present in the glasses, including H at roughly the 0.0001 mass fraction level. These glasses show promise for use as secondary standards for minor and trace element analyses of insulating materials such as synthetic ceramics, minerals, and silicate glasses. PMID:27446764

  13. Microbeam Characterization of Corning Archeological Reference Glasses: New Additions to the Smithsonian Microbeam Standard Collection.

    PubMed

    Vicenzi, Edward P; Eggins, Stephen; Logan, Amelia; Wysoczanski, Richard

    2002-01-01

    An initial study of the minor element, trace element, and impurities in Corning archeological references glasses have been performed using three microbeam techniques: electron probe microanalysis (EPMA), laser ablation ICP-mass spectrometry (LA ICP-MS), and secondary ion mass spectrometry (SIMS). The EPMA results suggest a significant level of heterogeneity for a number of metals. Conversely, higher precision and a larger sampling volume analysis by LA ICP-MS indicates a high degree of chemical uniformity within all glasses, typically <2 % relative (1 σ). SIMS data reveal that small but measurable quantities of volatile impurities are present in the glasses, including H at roughly the 0.0001 mass fraction level. These glasses show promise for use as secondary standards for minor and trace element analyses of insulating materials such as synthetic ceramics, minerals, and silicate glasses.

  14. Pesticide-sampling equipment, sample-collection and processing procedures, and water-quality data at Chicod Creek, North Carolina, 1992

    USGS Publications Warehouse

    Manning, T.K.; Smith, K.E.; Wood, C.D.; Williams, J.B.

    1994-01-01

    Water-quality samples were collected from Chicod Creek in the Coastal Plain Province of North Carolina during the summer of 1992 as part of the U.S. Geological Survey's National Water-Quality Assessment Program. Chicod Creek is in the Albemarle-Pamlico drainage area, one of four study units designated to test equipment and procedures for collecting and processing samples for the solid-phase extraction of selected pesticides, The equipment and procedures were used to isolate 47 pesticides, including organonitrogen, carbamate, organochlorine, organophosphate, and other compounds, targeted to be analyzed by gas chromatography/mass spectrometry. Sample-collection and processing equipment equipment cleaning and set-up procedures, methods pertaining to collecting, splitting, and solid-phase extraction of samples, and water-quality data resulting from the field test are presented in this report Most problems encountered during this intensive sampling exercise were operational difficulties relating to equipment used to process samples.

  15. Sampling and Selection Factors that Enhance the Diversity of Microbial Collections: Application to Biopesticide Development

    PubMed Central

    Park, Jun-Kyung; Lee, Seung-Hwan; Lee, Jang-Hoon; Han, Songhee; Kang, Hunseung; Kim, Jin-Cheol; Kim, Young Cheol; Gardener, Brian McSpadden

    2013-01-01

    Diverse bacteria are known to colonize plants. However, only a small fraction of that diversity has been evaluated for their biopesticide potential. To date, the criteria for sampling and selection in such bioprospecting endeavors have not been systematically evaluated in terms of the relative amount of diversity they provide for analysis. The present study aimed to enhance the success of bio-prospecting efforts by increasing the diversity while removing the genotypic redundancy often present in large collections of bacteria. We developed a multivariate sampling and marker-based selection strategy that significantly increase the diversity of bacteria recovered from plants. In doing so, we quantified the effects of varying sampling intensity, media composition, incubation conditions, plant species, and soil source on the diversity of recovered isolates. Subsequent sequencing and high-throughput phenotypic analyses of a small fraction of the collected isolates revealed that this approach led to the recovery of over a dozen rare and, to date, poorly characterized genera of plant-associated bacteria with significant biopesticide activities. Overall, the sampling and selection approach described led to an approximately 5-fold improvement in efficiency and the recovery of several novel strains of bacteria with significant biopesticide potential. PMID:25288941

  16. [Analysis of lead in unknown samples based on the standard addition method using laser induced breakdown spectroscopy].

    PubMed

    Fang, Li; Zhao, Nan-jing; Meng, De-shuo; Yuan, Jing; Tang, Jie; Wang, Yin; Yu, Yang; Ma, Ming-jun; Hu, Li; Zhang, Da-hai; Xiao, Xue; Wang, Yu; Liu, Jian-guo; Liu, Wen-qing

    2015-01-01

    The standard addition method with laser induced breakdown spectroscopy was used to analyze an unknown sample taken from a lead battery factory. the matrix influence on the results was effectively avoided when the external or internal standard method was used, and the pretreatment of samples was simple and quick. The Nd ' YAG pulse laser with wavelength 1 064 nm was used as the excitation source. The echelle spectroscopy with high resolution and wide spectral range was used as the spectral separation device, and the intensified charge coupled device (ICCD) as the spectral detection device in the experiment. The characteristic line at 405. 78 nrn was chosen as the analysis line to measure Pb concentration. Fe I : 404. 58 line was chosen as the internal standard. Pre-experiment was carried out to confirm the appropriate condition. Under the laser energy of 128. 5 mJ, the delay time of 2. 5 tps, and the gate width of 3 ps, it was determined that with the addition of Pb to the sample in the range of 0 and 25 000 mg . kg-1, there wasn't self-absorption. There was a good linear relationship between the intensity of the spectral line of 405. 78 nm and the addition of Pb. The appropriate concentration of Pb added into the sample for analysis was determined by this series of samples. On this basis, four samples were prepared with three parallel samples for each sample in order to verify the repeatability and reliability of the method, i. e. 5 000, 10 000, 15 000, 20 000 mg . kg-1 Pb was added into the original sample. The results were compared with the result of ICP-MS. The twelve samples' relative errors were between -24. 6% and 17. 6%. The average result was 43 069 mg . kg-1 with the relative error -2. 44%.

  17. A remotely operated serial sampler for collecting gas-tight fluid samples

    NASA Astrophysics Data System (ADS)

    Wu, Shi-jun; Yang, Can-jun; Ding, Kang; Tan, Chun-yang

    2015-10-01

    This paper describes the design, construction and preliminary test results for a gas-tight serial sampler intended to be deployed at seafloor for long-term operation to take time-series fluid samples from deep-sea environments such as cold seeps, water column and hydrothermal vents. The serial sampler is a modular system that is based on independent and identical sampling modules, which are designed to collect six 160 ml gas-tight fluid samples maintained at high pressure to a depth of 4000 meters. With two working modes, the sampler can be deployed either with seafloor cabled observatory for remote control or as a stand-alone device for autonomous operation. A prototype of the instrument has been constructed and tested on the MARS cabled observatory for two months. The laboratory and field tests proved the success of the design and construction of the serial sampler, and indicated the potential for future ocean sciences.

  18. Regression modeling of particle size distributions in urban storm water: advancements through improved sample collection methods

    USGS Publications Warehouse

    Fienen, Michael N.; Selbig, William R.

    2012-01-01

    A new sample collection system was developed to improve the representation of sediment entrained in urban storm water by integrating water quality samples from the entire water column. The depth-integrated sampler arm (DISA) was able to mitigate sediment stratification bias in storm water, thereby improving the characterization of suspended-sediment concentration and particle size distribution at three independent study locations. Use of the DISA decreased variability, which improved statistical regression to predict particle size distribution using surrogate environmental parameters, such as precipitation depth and intensity. The performance of this statistical modeling technique was compared to results using traditional fixed-point sampling methods and was found to perform better. When environmental parameters can be used to predict particle size distributions, environmental managers have more options when characterizing concentrations, loads, and particle size distributions in urban runoff.

  19. Comparative Evaluation of Drug Deposition in Hair Samples Collected from Different Anatomical Body Sites.

    PubMed

    Tzatzarakis, Manolis N; Alegakis, Athanasios K; Kavvalakis, Matthaios P; Vakonaki, Elena; Stivaktakis, Polychronis D; Kanaki, Katerina; Vardavas, Alexander I; Barbounis, Emmanouil G; Tsatsakis, Aristidis M

    2016-12-15

    In this study, we focused on the validation of a method for the simultaneous detection and quantification of cannabinoids, cocaine and opiates in hair as well as on the distribution of the drugs deposition in hair collected from different anatomical body sites. The proposed analytical procedure was validated for various parameters such as selectivity, linearity, limit of quantification, precision, accuracy, matrix effect and recovery. Four hundred and eighty-one samples were collected during 2010-2015 from 231 drug abusers. A 6-h ultrasonic-assisted methanolic extraction was applied for the isolation of the drugs. The analysis was performed in an liquid chromatography-mass spectrometry system for the opiates and cocaine and in a gas chromatography-mass spectrometry system for the cannabinoids. Cocaine was the most frequent detected drug (68.8-80.5%) followed by cannabinoids (47.6-63.3%) and opiates (34.7-46.7%) depending on the body site that the samples were collected. The mean concentrations of Δ(9)-tetrahydrocannabinol (THC) were 0.63 ± 2.11 for head, 0.54 ± 1.03 for pubic, 0.34 ± 0.51 for axillary and 0.18 ± 0.18 ng/mg for chest hair samples. The values of cocaine were 6.52 ± 15.98, 4.64 ± 10.77, 6.96 ± 38.21 and 3.94 ± 6.35 ng/mg, while the values of 6-monoacetylmorphine (MAM) were 3.33 ± 5.89, 3.06 ± 9.33, 1.37 ± 1.37 and 16.4 ± 1.77 ng/mg for head, pubic, axillary and chest samples, respectively. Differences between the detected concentrations of cocaine and opiates between the hair samples of different anatomical sites, as well as the ratio of drug metabolites to the parent compounds were observed in some cases. Statistically significant differences in the mean detected levels were noticed for morphine and heroin between head and pubic hair and also for cocaine and benzoylecgonine, between head and axillary hair samples. Moreover, the ratio of MAM to morphine and THC to cannabinol seems to correlate statistically with the total opiate or

  20. The Apollo Lunar Sample Image Collection: Digital Archiving and Online Access

    NASA Technical Reports Server (NTRS)

    Todd, Nancy S.; Lofgren, Gary E.; Stefanov, William L.; Garcia, Patricia A.

    2014-01-01

    The primary goal of the Apollo Program was to land human beings on the Moon and bring them safely back to Earth. This goal was achieved during six missions - Apollo 11, 12, 14, 15, 16, and 17 - that took place between 1969 and 1972. Among the many noteworthy engineering and scientific accomplishments of these missions, perhaps the most important in terms of scientific impact was the return of 382 kg (842 lb.) of lunar rocks, core samples, pebbles, sand, and dust from the lunar surface to Earth. Returned samples were curated at JSC (then known as the Manned Spacecraft Center) and, as part of the original processing, high-quality photographs were taken of each sample. The top, bottom, and sides of each rock sample were photographed, along with 16 stereo image pairs taken at 45-degree intervals. Photographs were also taken whenever a sample was subdivided and when thin sections were made. This collection of lunar sample images consists of roughly 36,000 photographs; all six Apollo missions are represented.

  1. Parameters of oxidative stress status in healthy subjects: their correlations and stability after sample collection.

    PubMed

    Firuzi, Omidreza; Mladenka, Premysl; Riccieri, Valeria; Spadaro, Antonio; Petrucci, Rita; Marrosu, Giancarlo; Saso, Luciano

    2006-01-01

    It has been proposed that sample storage may have some influence on the parameters of oxidative stress status (OSS) in biological fluids. We measured four important OSS parameters in plasma of 23 healthy subjects and repeated the measurements in the same samples kept at -70 degrees C after different time intervals. Hydroperoxides and total antioxidant capacity (TAC) were determined by ferrous ion oxidation in presence of xylenol orange (FOX) and ferric reducing antioxidant power (FRAP) assays, respectively. Sulfhydryls and carbonyls were measured spectrophotometrically. In fresh samples, OSS seemed to increase with age and relatively good correlations were found among different parameters. The mean values of hydroperoxides (6.08 microM), TAC (0.334 mM Trolox equivalent), and sulfhydryls (0.562 mM) in fresh samples did not show any significant change after 1, 7, and 30 days of storage. Mean carbonyl concentration determined after 1 day storage (2.0 nmol/mg protein) did not change after 30 days. However, extents of changes in hydroperoxide concentrations varied considerably from one individual to another, even after 1 day. A similar phenomenon was observed in TAC, but after 7 days. We suggest measuring hydroperoxides in fresh samples and TAC maximally after 1 week. Sulfhydryls and carbonyls showed more stability and can be measured at least 1 month after sample collection.

  2. Aqueous Processing of Atmospheric Organic Particles in Cloud Water Collected via Aircraft Sampling.

    PubMed

    Boone, Eric J; Laskin, Alexander; Laskin, Julia; Wirth, Christopher; Shepson, Paul B; Stirm, Brian H; Pratt, Kerri A

    2015-07-21

    Cloudwater and below-cloud atmospheric particle samples were collected onboard a research aircraft during the Southern Oxidant and Aerosol Study (SOAS) over a forested region of Alabama in June 2013. The organic molecular composition of the samples was studied to gain insights into the aqueous-phase processing of organic compounds within cloud droplets. High resolution mass spectrometry (HRMS) with nanospray desorption electrospray ionization (nano-DESI) and direct infusion electrospray ionization (ESI) were utilized to compare the organic composition of the particle and cloudwater samples, respectively. Isoprene and monoterpene-derived organosulfates and oligomers were identified in both the particles and cloudwater, showing the significant influence of biogenic volatile organic compound oxidation above the forested region. While the average O:C ratios of the organic compounds were similar between the atmospheric particle and cloudwater samples, the chemical composition of these samples was quite different. Specifically, hydrolysis of organosulfates and formation of nitrogen-containing compounds were observed for the cloudwater when compared to the atmospheric particle samples, demonstrating that cloud processing changes the composition of organic aerosol.

  3. ISOLATION OF Cryptococcus neoformans FROM ENVIRONMENTAL SAMPLES COLLECTED IN SOUTHEASTERN NIGERIA

    PubMed Central

    NWEZE, Emeka I.; KECHIA, Fred A.; DIBUA, Uju E.; EZE, Charles; ONOJA, Uwakwe S.

    2015-01-01

    SUMMARY Cryptococcosis caused by Cryptococcus neoformans is the second most common fungal opportunistic pathogen and a lifethreatening infection with serious clinical manifestations especially in HIV/AIDS and other immunocompromised patients. In Nigeria, HIV/AIDS infection has reached an alarming level. Despite this, information on the presence of this fungus in clinical and environmental samples is very scanty in Nigeria and many other parts of Africa. We set out to evaluate the presence of Cryptococcus neoformans or C. gattii in pigeon droppings obtained from Southeastern Nigeria. One hundred and seventy-seven samples of pigeon droppings from six sample types were collected. The area covered comprised of ten cities and other locations spanning across five States in Nigeria. Using established techniques, Cryptococcus neoformans was isolated from 39 of the 177 (22.0%) samples overall. No C. gattiiwas isolated. Most of the isolates (32.4%) were recovered from dovecotes (11 of 34) followed closely by samples taken from markets (31.8%; seven of 22) and least from the church (4.0%; one of 25). The highest isolation rate (38.9%) was found in samples from Enugu-Ezike(seven of 23) while the least came from Afikpoand the other locations each with 9.1% isolation rate. This is the first large-scale screening of Cryptococcus neoformans from pigeon droppings in Nigeria. The ecological and epidemiological significance of these findings are discussed. PMID:26422152

  4. Aqueous Processing of Atmospheric Organic Particles in Cloud Water Collected via Aircraft Sampling

    SciTech Connect

    Boone, Eric J.; Laskin, Alexander; Laskin, Julia; Wirth, Christopher; Shepson, Paul B.; Stirm, Brian H.; Pratt, Kerri A.

    2015-07-21

    Cloud water and below-cloud atmospheric particle samples were collected onboard a research aircraft during the Southern Oxidant and Aerosol Study (SOAS) over a forested region of Alabama in June 2013. The organic molecular composition of the samples was studied to gain insights into the aqueous-phase processing of organic compounds within cloud droplets. High resolution mass spectrometry with nanospray desorption electrospray ionization and direct infusion electrospray ionization were utilized to compare the organic composition of the particle and cloud water samples, respectively. Isoprene and monoterpene-derived organosulfates and oligomers were identified in both the particles and cloud water, showing the significant influence of biogenic volatile organic compound oxidation above the forested region. While the average O:C ratios of the organic compounds were similar between the atmospheric particle and cloud water samples, the chemical composition of these samples was quite different. Specifically, hydrolysis of organosulfates and formation of nitrogen-containing compounds were observed for the cloud water when compared to the atmospheric particle samples, demonstrating that cloud processing changes the composition of organic aerosol.

  5. Levels of organochlorine pesticide residues in butter samples collected from the Black Sea Region of Turkey.

    PubMed

    Aksoy, Abdurrahman; Dervisoglu, Muhammed; Guvenc, Dilek; Gul, Osman; Yazici, Fehmi; Atmaca, Enes

    2013-01-01

    The aim of the present study was to evaluate the levels of 9 organochlorine compounds (aldrin, hexachlorobenzene, 2,4-DDE, 4,4-DDE, 2,4-DDT, 4,4-DDT, and α-, β-, and γ-HCH) in butter samples collected in the Eastern, Middle and Western Black Sea Regions of Turkey between October 2009 and June 2010. The liquid-liquid extraction method was used to extract the organochlorine compounds from the samples and the measurements were performed by using a gas chromatograph-electron capture detector system. DDT metabolites, aldrin, hexachlorobenzene (HCB), and α-, and γ-HCH were not detected in the samples but β-HCH was detected in 3 of a total of 88 samples. In the first period, only one sample from the West Black Sea Region was β-HCH positive (0.014 mg kg(-1)). The other β-HCH positive samples collected in Middle and West Black Sea Regions in the second period had a concentration of 0.066 and 0.019 mg kg(-1), respectively. All concentrations of the detected compounds exceeded the legal limits of 0.003 mg kg(-1) for β-HCH, as prescribed by the Turkish Food Codex, and therefore pose a potential health risk for consumers. The contamination detected is most likely due to the past usage of β-HCH in agriculture and its long term persistence in the environment. These results strongly suggest that further research should be focused on the detection of pesticide residues in agricultural areas across the nation.

  6. [Logistics of collection and transportation of biological samples and the organization of the central laboratory in the ELSA-Brasil].

    PubMed

    Fedeli, Ligia G; Vidigal, Pedro G; Leite, Claudia Mendes; Castilhos, Cristina D; Pimentel, Robércia Anjos; Maniero, Viviane C; Mill, Jose Geraldo; Lotufo, Paulo A; Pereira, Alexandre C; Bensenor, Isabela M

    2013-06-01

    The ELSA (Estudo Longitudinal de Saúde do Adulto - Brazilian Longitudinal Study for Adult Health) is a multicenter cohort study which aims at the identification of risk factors associated with type 2 diabetes and cardiovascular diseases in the Brazilian population. The paper describes the strategies for the collection, processing, transportation, and quality control of blood and urine tests in the ELSA. The study decided to centralize the tests at one single laboratory. The processing of the samples was performed at the local laboratories, reducing the weight of the material to be transported, and diminishing the costs of transportation to the central laboratory at the Universidade de São Paulo Hospital. The study included tests for the evaluation of diabetes, insulin resistance, dyslipidemia, electrolyte abnormalities, thyroid hormones, uric acid, hepatic enzyme abnormalities, inflammation, and total blood cell count. In addition, leukocyte DNA, urine, plasma and serum samples were stored. The central laboratory performed approximately 375,000 tests.

  7. Estimation of actinide skeletal content in humans based on bone samples collected at autopsy.

    PubMed

    Filipy, R E; Alldredge, J R; Hall, C A; McInroy, J F; Glover, S E; Qualls, S

    2003-01-01

    The USTUR has developed simple linear and multiple regression models for estimating skeletal actinide concentrations on the basis of bone samples collected at autopsies of non-whole body tissue donors. Bone samples usually collected include a clavicle, the patella(e), one or more ribs, the sternum, and a vertebral wedge cut from within the abdominal cavity. The described models were derived by regression analyses with the analytical results from those bones and the entire skeletons of eight whole body donations to the USTUR. With the model, skeletal concentrations of 238Pu, (239+240)Pu, and 241Am can be estimated from wet or ashed actinide concentrations in one to five of the bones usually collected at autopsy and analyzed. Application of the models to a selected USTUR non-whole body donation (Case 0240) indicated that the skeletal actinide concentration estimates were reasonably precise and that there was good agreement between the results from individual bones with wet or ashed actinide concentrations. The USTUR will apply the model that is based on wet concentrations of bones to estimate skeletal concentrations of actinides in all non-whole body autopsy cases for the sake of consistency because of the large number of early cases for which ashed weights of bones were not recorded.

  8. Conceptual study and key technology development for Mars Aeroflyby sample collection

    NASA Astrophysics Data System (ADS)

    Fujita, K.; Ozawa, T.; Okudaira, K.; Mikouchi, T.; Suzuki, T.; Takayanagi, H.; Tsuda, Y.; Ogawa, N.; Tachibana, S.; Satoh, T.

    2014-01-01

    Conceptual study of Mars Aeroflyby Sample Collection (MASC) is conducted as a part of the next Mars exploration mission currently entertained in Japan Aerospace Exploration Agency. In the mission scenario, an atmospheric entry vehicle is flown into the Martian atmosphere, collects the Martian dust particles as well as atmospheric gases during the guided hypersonic flight, exits the Martian atmosphere, and is inserted into a parking orbit from which a return system departs for the earth to deliver the dust and gas samples. In order to accomplish a controlled flight and a successful orbit insertion, aeroassist orbit transfer technologies are introduced into the guidance and control system. System analysis is conducted to assess the feasibility and to make a conceptual design, finding that the MASC system is feasible at the minimum system mass of 600 kg approximately. The aerogel, which is one of the candidates for the dust sample collector, is assessed by arcjet heating tests to examine its behavior when exposed to high-temperature gases, as well as by particle impingement tests to evaluate its dust capturing capability.

  9. Miniature CVD-diamond corning drills for robotic sample collection and analysis.

    SciTech Connect

    Vaniman, D. T.; Trava-Airoldi, V.J.; Bish, D. L.; Chipera, S. J.

    2003-01-01

    Coring tools have been used etlectivelv on the Moon, but to date no such tools have been used on any other extraterrestrial surface. The lunar experience includes both manual (Apollo) and robotic (Luna) systems . These coring systems were concerned primarily with acquiring samples from depth for return to Earth or for the creation of instrument emplacement holes (e .g ., heat probes). Current designs for planetary drills differ from the lunar tools primarily in that they are integrated with robotic instrumentation for remote analysis, but the role of the drilling or coring system remains one of acquiring samples that must be extracted from the core barrel for analysis . Missing from current sample collection systems is a tool that can double as both a conng device and a sample holder. This dual utility can minimize the number of motions, the mass, and the power required for several classes of instruments in planetary surface exploration. To be effective, such a system must be durable and simple in operation. Hollow CVD diamond drills possess the hardness, excellent cutting properties, and heat resistance required for drilling into a wide variety of rocks and minerals. Because CVD diamond is also unreactive and transparent to infrared radiation and to X-rays of moderate to high energry, it can be used as a sample holder in various instruments for X-ray diffraction (XRD), Xray fluorescence (XRF), infrared spectroscopy, Raman spectroscopy, and thermal analysis.

  10. Diffraction cartography: applying microbeams to macromolecular crystallography sample evaluation and data collection.

    PubMed

    Bowler, Matthew W; Guijarro, Matias; Petitdemange, Sebastien; Baker, Isabel; Svensson, Olof; Burghammer, Manfred; Mueller-Dieckmann, Christoph; Gordon, Elspeth J; Flot, David; McSweeney, Sean M; Leonard, Gordon A

    2010-08-01

    Crystals of biological macromolecules often exhibit considerable inter-crystal and intra-crystal variation in diffraction quality. This requires the evaluation of many samples prior to data collection, a practice that is already widespread in macromolecular crystallography. As structural biologists move towards tackling ever more ambitious projects, new automated methods of sample evaluation will become crucial to the success of many projects, as will the availability of synchrotron-based facilities optimized for high-throughput evaluation of the diffraction characteristics of samples. Here, two examples of the types of advanced sample evaluation that will be required are presented: searching within a sample-containing loop for microcrystals using an X-ray beam of 5 microm diameter and selecting the most ordered regions of relatively large crystals using X-ray beams of 5-50 microm in diameter. A graphical user interface developed to assist with these screening methods is also presented. For the case in which the diffraction quality of a relatively large crystal is probed using a microbeam, the usefulness and implications of mapping diffraction-quality heterogeneity (diffraction cartography) are discussed. The implementation of these techniques in the context of planned upgrades to the ESRF's structural biology beamlines is also presented.

  11. Comparative evaluation of vacuum-based surface sampling methods for collection of Bacillus spores

    PubMed Central

    Calfee, M. Worth; Rose, Laura J.; Morse, Stephen; Mattorano, Dino; Clayton, Matt; Touati, Abderrahmane; Griffin-Gatchalian, Nicole; Slone, Christina; McSweeney, Neal

    2016-01-01

    In this study, four commonly-used sampling devices (vacuum socks, 37 mm 0.8 μm mixed cellulose ester (MCE) filter cassettes, 37 mm 0.3 μm polytetrafluoroethylene (PTFE) filter cassettes, and 3M™ forensic filters) were comparatively evaluated for their ability to recover surface-associated spores. Aerosolized spores (~105 CFU cm−2) of a Bacillus anthracis surrogate were allowed to settle onto three material types (concrete, carpet, and upholstery). Ten replicate samples were collected using each vacuum method, from each material type. Stainless steel surfaces, inoculated simultaneously with test materials, were sampled with pre-moistened wipes. Wipe recoveries were utilized to normalize vacuum-based recoveries across trials. Recovery (CFU cm−2) and relative recovery (vacuum recovery/wipe recovery) were determined for each method and material type. Recoveries and relative recoveries ranged from 3.8 × 103 to 7.4 × 104 CFU cm−2 and 0.035 to 1.242, respectively. ANOVA results indicated that the 37 mm MCE method exhibited higher relative recoveries than the other methods when used for sampling concrete or upholstery. While the vacuum sock resulted in the highest relative recoveries on carpet, no statistically significant difference was detected. The results of this study may be used to guide selection of sampling approaches following biological contamination incidents. PMID:24184017

  12. Comparative evaluation of vacuum-based surface sampling methods for collection of Bacillus spores.

    PubMed

    Calfee, M Worth; Rose, Laura J; Morse, Stephen; Mattorano, Dino; Clayton, Matt; Touati, Abderrahmane; Griffin-Gatchalian, Nicole; Slone, Christina; McSweeney, Neal

    2013-12-01

    In this study, four commonly-used sampling devices (vacuum socks, 37 mm 0.8 μm mixed cellulose ester (MCE) filter cassettes, 37 mm 0.3 μm polytetrafluoroethylene (PTFE) filter cassettes, and 3M™ forensic filters) were comparatively evaluated for their ability to recover surface-associated spores. Aerosolized spores (~10(5)CFUcm(-2)) of a Bacillus anthracis surrogate were allowed to settle onto three material types (concrete, carpet, and upholstery). Ten replicate samples were collected using each vacuum method, from each material type. Stainless steel surfaces, inoculated simultaneously with test materials, were sampled with pre-moistened wipes. Wipe recoveries were utilized to normalize vacuum-based recoveries across trials. Recovery (CFUcm(-2)) and relative recovery (vacuum recovery/wipe recovery) were determined for each method and material type. Recoveries and relative recoveries ranged from 3.8 × 10(3) to 7.4 × 10(4)CFUcm(-2) and 0.035 to 1.242, respectively. ANOVA results indicated that the 37 mm MCE method exhibited higher relative recoveries than the other methods when used for sampling concrete or upholstery. While the vacuum sock resulted in the highest relative recoveries on carpet, no statistically significant difference was detected. The results of this study may be used to guide selection of sampling approaches following biological contamination incidents.

  13. Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure with image analysis

    DOEpatents

    Van Berkel, Gary J.; Kertesz, Vilmos

    2011-08-09

    A system and method utilizes an image analysis approach for controlling the collection instrument-to-surface distance in a sampling system for use, for example, with mass spectrometric detection. Such an approach involves the capturing of an image of the collection instrument or the shadow thereof cast across the surface and the utilization of line average brightness (LAB) techniques to determine the actual distance between the collection instrument and the surface. The actual distance is subsequently compared to a target distance for re-optimization, as necessary, of the collection instrument-to-surface during an automated surface sampling operation.

  14. The heavy metal content of wild edible mushroom samples collected in canakkale province, Turkey.

    PubMed

    Cayir, Akin; Coşkun, Münevver; Coşkun, Mahmut

    2010-05-01

    In this study, concentrations of heavy metals (Cd, Cr, Cu, Pb, and Zn) were determined in three edible mushroom species (Lactarius deliciosus, Russula delica, and Rhizopogon roseolus) collected in five sampling sites in Canakkale province, Turkey. Mean values of Cd, Cr, Cu, Pb, and Zn were 0.72, 0.26, 28.34, 1.53, and 64.62 mg/kg, respectively. The highest concentrations of Cd, Cu, Pb, and Zn were determined in species R. delica, while Cr was observed in L. deliciosus. In terms of the nutritional aspect, taking into account the concentration of Provisional Tolerable Weekly Intake recommended by FAO/WHO, the maximum concentration of Cd is a restrictive factor for consumption of the collected mushroom species. The concentrations of the other elements have no health risks when consumed at optimal levels.

  15. Percent recoveries of anthropogenic organic compounds with and without the addition of ascorbic acid to preserve finished-water samples containing free chlorine, 2004-10

    USGS Publications Warehouse

    Valder, Joshua F.; Delzer, Gregory C.; Bender, David A.; Price, Curtis V.

    2011-01-01

    This report presents finished-water matrix-spike recoveries of 270 anthropogenic organic compounds with and without the addition of ascorbic acid to preserve water samples containing free chlorine. Percent recoveries were calculated using analytical results from a study conducted during 2004-10 for the National Water-Quality Assessment (NAWQA) Program of the U.S. Geological Survey (USGS). The study was intended to characterize the effect of quenching on finished-water matrix-spike recoveries and to better understand the potential oxidation and transformation of 270 anthropogenic organic compounds. The anthropogenic organic compounds studied include those on analytical schedules 1433, 2003, 2033, 2060, 2020, and 4024 of the USGS National Water Quality Laboratory. Three types of samples were collected from 34 NAWQA locations across the Nation: (1) quenched finished-water samples (not spiked), (2) quenched finished-water matrix-spike samples, and (3) nonquenched finished-water matrix-spike samples. Percent recoveries of anthropogenic organic compounds in quenched and nonquenched finished-water matrix-spike samples are presented. Comparisons of percent recoveries between quenched and nonquenched spiked samples can be used to show how quenching affects finished-water samples. A maximum of 18 surface-water and 34 groundwater quenched finished-water matrix-spike samples paired with nonquenched finished-water matrix-spike samples were analyzed. Percent recoveries for the study are presented in two ways: (1) finished-water matrix-spike samples supplied by surface-water or groundwater, and (2) by use (or source) group category for surface-water and groundwater supplies. Graphical representations of percent recoveries for the quenched and nonquenched finished-water matrix-spike samples also are presented.

  16. Strategy to obtain axenic cultures from field-collected samples of the cyanobacterium Phormidium animalis.

    PubMed

    Vázquez-Martínez, Guadalupe; Rodriguez, Mario H; Hernández-Hernández, Fidel; Ibarra, Jorge E

    2004-04-01

    An efficient strategy, based on a combination of procedures, was developed to obtain axenic cultures from field-collected samples of the cyanobacterium Phormidium animalis. Samples were initially cultured in solid ASN-10 medium, and a crude separation of major contaminants from P. animalis filaments was achieved by washing in a series of centrifugations and resuspensions in liquid medium. Then, manageable filament fragments were obtained by probe sonication. Fragmentation was followed by forceful washing, using vacuum-driven filtration through an 8-microm pore size membrane and an excess of water. Washed fragments were cultured and treated with a sequential exposure to four different antibiotics. Finally, axenic cultures were obtained from serial dilutions of treated fragments. Monitoring under microscope examination and by inoculation in Luria-Bertani (LB) agar plates indicated either axenicity or the degree of contamination throughout the strategy.

  17. Ram-air sample collection device for a chemical warfare agent sensor

    DOEpatents

    Megerle, Clifford A.; Adkins, Douglas R.; Frye-Mason, Gregory C.

    2002-01-01

    In a surface acoustic wave sensor mounted within a body, the sensor having a surface acoustic wave array detector and a micro-fabricated sample preconcentrator exposed on a surface of the body, an apparatus for collecting air for the sensor, comprising a housing operatively arranged to mount atop the body, the housing including a multi-stage channel having an inlet and an outlet, the channel having a first stage having a first height and width proximate the inlet, a second stage having a second lower height and width proximate the micro-fabricated sample preconcentrator, a third stage having a still lower third height and width proximate the surface acoustic wave array detector, and a fourth stage having a fourth height and width proximate the outlet, where the fourth height and width are substantially the same as the first height and width.

  18. Methods for collecting benthic invertebrate samples as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Cuffney, Thomas F.; Gurtz, Martin E.; Meador, Michael R.

    1993-01-01

    Benthic invertebrate communities are evaluated as part of the ecological survey component of the U.S. Geological Survey's National Water-Quality Assessment Program. These biological data are collected along with physical and chemical data to assess water-quality conditions and to develop an understanding of the factors that affect water-quality conditions locally, regionally, and nationally. The objectives of benthic invertebrate community characterizations are to (1) develop for each site a list of tax a within the associated stream reach and (2) determine the structure of benthic invertebrate communities within selected habitats of that reach. A nationally consistent approach is used to achieve these objectives. This approach provides guidance on site, reach, and habitat selection and methods and equipment for qualitative multihabitat sampling and semi-quantitative single habitat sampling. Appropriate quality-assurance and quality-control guidelines are used to maximize the ability to analyze data within and among study units.

  19. Biobanks for research. Ethical and legal aspects in human biological samples collections in France.

    PubMed

    Noiville, Christine

    2012-06-01

    Because they gather huge quantities of human biological samples and information allowing for better understanding of diseases, biobanks appear as a very powerful tool for boosting both medical research and public health as a whole. Although France does not really appear as a leader in biobanking compared to China or UK, biobanks and other samples collections abound in our country and have then been regulated, even though french law does not use the term biobank as such. The present article gives an overview of the current legal framework and explores the remaining ethical and legal issues, concerning particularly the protection of donors, the sharing of biobanks content and the sharing of biobanks benefits. The article explains how these universal questions arise in this country and what answers (sometimes specific) they get or could get in the following years.

  20. Geochemistry of Rock Samples Collected from the Iron Hill Carbonatite Complex, Gunnison County, Colorado

    USGS Publications Warehouse

    Van Gosen, Bradley S.

    2008-01-01

    A study conducted in 2006 by the U.S. Geological Survey collected 57 surface rock samples from nine types of intrusive rock in the Iron Hill carbonatite complex. This intrusive complex, located in Gunnison County of southwestern Colorado, is known for its classic carbonatite-alkaline igneous geology and petrology. The Iron Hill complex is also noteworthy for its diverse mineral resources, including enrichments in titanium, rare earth elements, thorium, niobium (columbium), and vanadium. This study was performed to reexamine the chemistry and metallic content of the major rock units of the Iron Hill complex by using modern analytical techniques, while providing a broader suite of elements than the earlier published studies. The report contains the geochemical analyses of the samples in tabular and digital spreadsheet format, providing the analytical results for 55 major and trace elements.

  1. Effects of the number of people on efficient capture and sample collection: a lion case study.

    PubMed

    Ferreira, Sam M; Maruping, Nkabeng T; Schoultz, Darius; Smit, Travis R

    2013-05-24

    Certain carnivore research projects and approaches depend on successful capture of individuals of interest. The number of people present at a capture site may determine success of a capture. In this study 36 lion capture cases in the Kruger National Park were used to evaluate whether the number of people present at a capture site influenced lion response rates and whether the number of people at a sampling site influenced the time it took to process the collected samples. The analyses suggest that when nine or fewer people were present, lions appeared faster at a call-up locality compared with when there were more than nine people. The number of people, however, did not influence the time it took to process the lions. It is proposed that efficient lion capturing should spatially separate capture and processing sites and minimise the number of people at a capture site.

  2. Extending the Collection Duration of Breath Samples for Enteric Methane Emission Estimation Using the SF₆ Tracer Technique.

    PubMed

    Pinares-Patiño, César; Gere, José; Williams, Karen; Gratton, Roberto; Juliarena, Paula; Molano, German; MacLean, Sarah; Sandoval, Edgar; Taylor, Grant; Koolaard, John

    2012-06-08

    The daily sample collection protocol of the sulphur hexafluoride (SF₆) tracer technique for the estimation of methane (CH₄) emissions from ruminants may not be practical under extensive grazing systems. Here, under controlled conditions, we evaluated extended periods of sampling as an alternative to daily sample collections. Eight rumen-fistulated cows were housed and fed lucerne silage to achieve common daily feed intakes of 6.4 kg dry matter per cow. Following SF₆ permeation tube dosing, eight sampling lines were fitted to the breath collection harness, so that a common gas mix was available to each line. Half of the lines collected samples into PVC yokes using a modified capillary system as commonly used in New Zealand (NZL), and half collected samples into stainless steel cylinders using a ball-bearing flow restrictor as used in Argentina (ARG), all within a 10-day time frame, either daily, across two consecutive 5-day periods or across one 10-day period (in duplicate). The NZL system had greater sampling success (97.3 vs. 79.5%) and yielded more consistent CH₄ emission estimates than the ARG system. Emission estimates from NZL daily, NZL 5-day and NZL 10-day samplings were 114, 110 and 111 g d(-1), respectively. Extended sample collection protocol may be feasible, but definitive evaluation of this alternative as well as sample collection systems is required under grazing situations before a decision on recommendation can be made.

  3. Organophosphate esters in dust samples collected from Danish homes and daycare centers.

    PubMed

    Langer, Sarka; Fredricsson, Malin; Weschler, Charles J; Bekö, Gabriel; Strandberg, Bo; Remberger, Mikael; Toftum, Jørn; Clausen, Geo

    2016-07-01

    Organophosphates are used in a wide range of materials and consumer products and are ubiquitous in indoor environments. Certain organophosphates have been associated with various adverse health effects. The present paper reports mass fractions of organophosphates in dust samples collected from 500 bedrooms and 151 daycare centers of children living in Odense, Denmark. The identified compounds include: tris(isobutyl) phosphate (TIBP), tri-n-butyl phosphate (TNBP), tris(2-chloroethyl) phosphate (TCEP), tris(2-chloroisopropyl) phosphate (TCIPP), tris(1,3-dichloroisopropyl) phosphate (TDCIPP), tris(2-butoxyethyl) phosphate (TBOEP), triphenylphosphate (TPHP), 2-ethylhexyl-diphenyl phosphate (EHDPP), tris(2-ethylhexyl) phosphate (TEHP) and tris(methylphenyl) phosphate (TMPP). Both the number of organophosphates with median values above the limit of detection and the median values were higher for samples from daycare centers than for samples from homes. Organophosphates with median mass fractions above the limit of detection were: TCEP from homes (6.9 μg g(-1)), and TCEP (16 μg g(-1)), TCIPP (5.6 μg g(-1)), TDCIPP (7.1 μg g(-1)), TBOEP (26 μg g(-1)), TPHP (2.0 μg g(-1)) and EHDPP (2.1 μg g(-1)) from daycare centers. When present, TBOEP was typically the most abundant of the identified OPs. The sum of the organophosphate dust mass fractions measured in this study was roughly in the mid-range of summed mass fractions reported for dust samples collected in other countries. On a global scale, the geographical distribution of organophosphates in indoor dust is quite variable, with higher concentrations in industrialized countries. This trend differs from that for phthalate esters, whose geographic distribution is more homogeneous. Exposure to organophosphates via dust ingestion is relatively low, although there is considerable uncertainly in this assessment.

  4. The role of variations in growth rate and sample collection on interpreting results of segmental analyses of hair.

    PubMed

    LeBeau, Marc A; Montgomery, Madeline A; Brewer, Jason D

    2011-07-15

    corresponds to hair formed 1.3±0.2 to 2.2±0.4 months (95% confidence) earlier. The impact of these findings as it relates to the corresponding time for each additional segment is demonstrated. As a result, we recommend that hair collection be delayed 8 weeks after a suspected ingestion to ensure that the sample fully represents the exposure period. The results of this study suggest that the variability in the growth rate of human head hair, as well as the inconsistent collection of hair, significantly affect the interpretation of results from segmental analysis of hair.

  5. Activity concentrations of environmental samples collected in Fukushima Prefecture immediately after the Fukushima nuclear accident

    PubMed Central

    Hosoda, Masahiro; Tokonami, Shinji; Tazoe, Hirofumi; Sorimachi, Atsuyuki; Monzen, Satoru; Osanai, Minoru; Akata, Naofumi; Kakiuchi, Hideki; Omori, Yasutaka; Ishikawa, Tetsuo; Sahoo, Sarata K.; Kovács, Tibor; Yamada, Masatoshi; Nakata, Akifumi; Yoshida, Mitsuaki; Yoshino, Hironori; Mariya, Yasushi; Kashiwakura, Ikuo

    2013-01-01

    Radionuclide concentrations in environmental samples such as surface soils, plants and water were evaluated by high purity germanium detector measurements. The contribution rate of short half-life radionuclides such as 132I to the exposure dose to residents was discussed from the measured values. The highest values of the 131I/137Cs activity ratio ranged from 49 to 70 in the environmental samples collected at Iwaki City which is located to the south of the F1-NPS. On the other hand, the 132I/131I activity ratio in the same environmental samples had the lowest values, ranging from 0.01 to 0.02. By assuming that the 132I/131I activity ratio in the atmosphere was equal to the ratio in the environmental samples, the percent contribution to the thyroid equivalent dose by 132I was estimated to be less than 2%. Moreover, the contribution to the thyroid exposure by 132I might be negligible if 132I contamination was restricted to Iwaki City. PMID:23887080

  6. Journal: A Review of Some Tracer-Test Design Equations for Tracer-Mass Estimation and Sample Collection Frequency

    EPA Science Inventory

    Determination of necessary tracer mass, initial sample-collection time, and subsequent sample-collection frequency are the three most difficult aspects to estimate for a proposed tracer test prior to conducting the tracer test. To facilitate tracer-mass estimation, 33 mass-estima...

  7. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF SOIL SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.20)

    EPA Science Inventory

    This SOP describes the method for collecting soil samples from the child's outdoor play area to measure for persistent organic pollutants. Soil samples are collected by scraping up the top 0.5 cm of soil in a 0.095 m2 (1 ft2) area in the middle of the child's play area.

  8. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF DISLODGEABLE RESIDUES -- PUF ROLLER SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.18)

    EPA Science Inventory

    This SOP describes the method to collect transferable residues from indoor floor surfaces. The sampling procedures described are applicable to bare floors or covered floor surfaces, e.g., carpeting and vinyl flooring. The samples will be collected only in the day care centers o...

  9. PIXE Analysis of Atmospheric Aerosol Samples Collected in the Adirondack Mountains

    NASA Astrophysics Data System (ADS)

    Yoskowitz, Josh; Ali, Salina; Nadareski, Benjamin; Safiq, Alexandrea; Smith, Jeremy; Labrake, Scott; Vineyard, Michael

    2013-10-01

    We have performed an elemental analysis of atmospheric aerosol samples collected at Piseco Lake in Upstate New York using proton induced x-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the samples and distribute the particulate matter onto Kapton foils by particle size. The PIXE experiments were performed with 2.2-MeV proton beams from the 1.1-MV pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. X-Ray energy spectra were measured with a silicon drift detector and analyzed with GUPIX software to determine the elemental concentrations of the aerosols. A broad range of elements from silicon to zinc were detected with significant sulfur concentrations measured for particulate matter between 0.25 and 0.5 μm in size. The PIXE analysis will be described and preliminary results will be presented.

  10. Ground-Water Data-Collection Protocols and Procedures for the National Water-Quality Assessment Program: Collection and Documentation of Water-Quality Samples and Related Data

    USGS Publications Warehouse

    Koterba, Michael T.; Wilde, Franceska D.; Lapham, Wayne W.

    1995-01-01

    Protocols for ground-water sampling are described in a report written in 1989 as part of the pilot program for the National Water-Quality Assessment (NAWQA) Program of the U.S. Geological Survey (USGS). These protocols have been reviewed and revised to address the needs of the full-scale implementation of the NAWQA Program that began in 1991. This report, which is a collaborative effort between the NAWQA Program and the USGS Office of Water Quality, is the result of that review and revision. This report describes protocols and recommended procedures for the collection of water-quality samples and related data from wells for the NAWQA Program. Protocols and recommended procedures discussed include (1) equipment setup and other preparations for data collection; (2) well purging and field measurements; (3) collecting and processing ground-water-quality samples; (4) equipment decontamination; (5) quality-control sampling; and (6) sample handling and shipping.

  11. Extending the Collection Duration of Breath Samples for Enteric Methane Emission Estimation Using the SF6 Tracer Technique

    PubMed Central

    Pinares-Patiño, César; Gere, José; Williams, Karen; Gratton, Roberto; Juliarena, Paula; Molano, German; MacLean, Sarah; Sandoval, Edgar; Taylor, Grant; Koolaard, John

    2012-01-01

    Simple Summary Extended sample collection for the SF6 tracer technique is desirable for extensive grazing systems. Breath samples from eight cows were collected while lucerne silage was fed to achieve fixed intakes among the cows. Samples were collected over a 10-day period, using either apparatuses used in New Zealand (NZL) or Argentina (ARG), and either daily, over two consecutive 5-day periods or over a 10-day period (in duplicate). The NZL system had a greater sampling success and more consistent CH4 emission estimates than the ARG system, with no differences in mean emissions among sample collection periods. This study showed that extended sample collection is feasible, but definitive evaluation under grazing situation is required before a decision on recommendation can be made. Abstract The daily sample collection protocol of the sulphur hexafluoride (SF6) tracer technique for the estimation of methane (CH4) emissions from ruminants may not be practical under extensive grazing systems. Here, under controlled conditions, we evaluated extended periods of sampling as an alternative to daily sample collections. Eight rumen-fistulated cows were housed and fed lucerne silage to achieve common daily feed intakes of 6.4 kg dry matter per cow. Following SF6 permeation tube dosing, eight sampling lines were fitted to the breath collection harness, so that a common gas mix was available to each line. Half of the lines collected samples into PVC yokes using a modified capillary system as commonly used in New Zealand (NZL), and half collected samples into stainless steel cylinders using a ball-bearing flow restrictor as used in Argentina (ARG), all within a 10-day time frame, either daily, across two consecutive 5-day periods or across one 10-day period (in duplicate). The NZL system had greater sampling success (97.3 vs. 79.5%) and yielded more consistent CH4 emission estimates than the ARG system. Emission estimates from NZL daily, NZL 5-day and NZL 10-day samplings

  12. Self-collected breath sampling for monitoring low-level benzene exposures among automobile mechanics.

    PubMed

    Egeghy, Peter P; Nylander-French, Leena; Gwin, Kristin K; Hertz-Picciotto, Irva; Rappaport, Stephen M

    2002-07-01

    Automobile mechanics are exposed to benzene through their contact with gasoline vapor and engine exhaust. This study investigated the benzene uptake associated with these exposures. We first evaluated the reliability of self-collected breath samples among a subset of subjects and found good agreement between these samples and those collected under expert supervision (intraclass correlation coefficient 0.79, n = 69). We then used self-monitoring together with a longitudinal sampling design (with up to three measurements per worker) to measure benzene in air and benzene in end-exhaled breath among 81 workers from 12 automobile repair garages in North Carolina. A statistically significant difference (P < 0.0001, Mann-Whitney rank sum test) was observed between non-smokers and smokers for post-exposure benzene concentration in breath (median values of 18.9 and 39.1 micro g/m(3), respectively). Comparing pre- and post-exposure breath concentrations within these two groups, the difference was significant among non-smokers (P < 0.0001) but not significant among smokers (P > 0.05). Mixed effects regression analysis using backwards elimination yielded five significant predictors of benzene concentration in breath, namely benzene exposure (P < 0.0001), pre-exposure benzene concentration in breath (P = 0.021), smoking status (P < 0.0001), fuel system work (P = 0.0043) and carburetor cleaner use (P < 0.0001). The between-person variance component comprised only 28% of the total variance in benzene levels in breath, indicating that differences among individuals related to physiological and metabolic characteristics had little influence on benzene uptake among these workers.

  13. Detection of hepatitis E virus in samples of animal origin collected in Hungary.

    PubMed

    Forgách, Petra; Nowotny, Norbert; Erdélyi, Károly; Boncz, Attila; Zentai, János; Szucs, György; Reuter, Gábor; Bakonyi, Tamás

    2010-07-14

    Hepatitis E virus (HEV) is an enterically transmitted human pathogen. HEV infections are mainly associated with acute, self-limited, icteric hepatitis with an average mortality rate of 1%. Animal reservoirs are considered to play an important role in the maintenance of the virus and in the spread of HEV to humans. HEV-induced seroconversion was described in several species, however clinical hepatitis in animals has not been observed to date. HEV strains from animals are genetically closely related to human HEV isolates, which supports the opinions on the zoonotic transmission of the virus. In this expansive study the occurrence of HEV was investigated in Hungarian wild and domesticated animal samples. HEV RNA was detected by reverse transcription-polymerase chain reaction in liver samples of wild boars, roe deer, and deer. The investigations of domestic swine samples detected HEV in 39% of the investigated Hungarian pig farms. Simultaneous investigation revealed no definite difference between liver and faeces samples of domestic pigs in the frequency of HEV positivity. The highest (36%) incidence of HEV infection was found among the 11-16-week-old pigs. Samples from domestic cattle and rodents collected in pig farms, forests and meadows were tested negative for HEV RNA. Phylogenetic analysis of partial sequences amplified within the ORF1 and ORF2 regions of selected strains revealed that the detected viruses belong to three subgroups of the third genogroup of HEV, and are closely related to human and swine HEV strains detected in different countries. The investigations revealed widespread distribution of HEV in Hungarian wild ungulate and domesticated swine populations, with considerable genetic diversity among the strains.

  14. Fiber-based solid phase microextraction using fused silica lined bottles to collect, store, and stabilize a multianalyte headspace gas sample for offline analyses.

    PubMed

    Harvey, Chris A; Carter, J Chance; Ertel, John R; Alviso, Cindy T; Chinn, Sarah C; Maxwell, Robert S

    2015-07-03

    We have developed a solid phase microextraction (SPME) sampling method using fused silica lined bottles (400 ml) to collect, store, and stabilize a headspace subsample from the source for subsequent offline, repetitive analyses of the gas using fiber-based SPME. The method enables long-term stability for repeated offline analysis of the organic species collected from the source headspace and retains all the advantages of fiber SPME sampling (e.g. rapid extraction, solvent free, simple and inexpensive) while providing additional advantages. Typically, the analytes collected on the SPME fiber must be desorbed and analyzed immediately to mitigate analyte loss or contamination. The new SPME sampling method, conducted offline using carboxen/polydimethylsiloxane (carboxen/PDMS - 85 μm) coated fibers, has been shown to be identical to in situ SPME sampling of a headspace acquired from an 80 component organic matrix with reproducibility demonstrated to be less than %RSD=7.0% for replicate samples measured over a 30-day period. In addition, repetitive samplings from one headspace aliquot are possible using one or more fibers and fiber types as well as quantitative options such as internal standard addition as demonstrated in a feasibility study using a benzene/toluene/xylene (BTX; 1 ppmv) certified gas standard, in which the SPME measurement precision (%RSD) was improved by a factor of 1.5-1.9 compared to the use of an external standard.

  15. The CUPID (Cultural and Psychosocial Influences on Disability) Study: Methods of Data Collection and Characteristics of Study Sample

    PubMed Central

    Coggon, David; Ntani, Georgia; Palmer, Keith T.; Felli, Vanda E.; Harari, Raul; Barrero, Lope H.; Felknor, Sarah A.; Gimeno, David; Cattrell, Anna; Serra, Consol; Bonzini, Matteo; Solidaki, Eleni; Merisalu, Eda; Habib, Rima R.; Sadeghian, Farideh; Kadir, Masood; Warnakulasuriya, Sudath S. P.; Matsudaira, Ko; Nyantumbu, Busisiwe; Sim, Malcolm R.; Harcombe, Helen; Cox, Ken; Marziale, Maria H.; Sarquis, Leila M.; Harari, Florencia; Freire, Rocio; Harari, Natalia; Monroy, Magda V.; Quintana, Leonardo A.; Rojas, Marianela; Salazar Vega, Eduardo J.; Harris, E. Clare; Vargas-Prada, Sergio; Martinez, J. Miguel; Delclos, George; Benavides, Fernando G.; Carugno, Michele; Ferrario, Marco M.; Pesatori, Angela C.; Chatzi, Leda; Bitsios, Panos; Kogevinas, Manolis; Oha, Kristel; Sirk, Tuuli; Sadeghian, Ali; Peiris-John, Roshini J.; Sathiakumar, Nalini; Wickremasinghe, A. Rajitha; Yoshimura, Noriko; Kielkowski, Danuta; Kelsall, Helen L.; Hoe, Victor C. W.; Urquhart, Donna M.; Derett, Sarah; McBride, David; Gray, Andrew

    2012-01-01

    Background The CUPID (Cultural and Psychosocial Influences on Disability) study was established to explore the hypothesis that common musculoskeletal disorders (MSDs) and associated disability are importantly influenced by culturally determined health beliefs and expectations. This paper describes the methods of data collection and various characteristics of the study sample. Methods/Principal Findings A standardised questionnaire covering musculoskeletal symptoms, disability and potential risk factors, was used to collect information from 47 samples of nurses, office workers, and other (mostly manual) workers in 18 countries from six continents. In addition, local investigators provided data on economic aspects of employment for each occupational group. Participation exceeded 80% in 33 of the 47 occupational groups, and after pre-specified exclusions, analysis was based on 12,426 subjects (92 to 1018 per occupational group). As expected, there was high usage of computer keyboards by office workers, while nurses had the highest prevalence of heavy manual lifting in all but one country. There was substantial heterogeneity between occupational groups in economic and psychosocial aspects of work; three- to five-fold variation in awareness of someone outside work with musculoskeletal pain; and more than ten-fold variation in the prevalence of adverse health beliefs about back and arm pain, and in awareness of terms such as “repetitive strain injury” (RSI). Conclusions/Significance The large differences in psychosocial risk factors (including knowledge and beliefs about MSDs) between occupational groups should allow the study hypothesis to be addressed effectively. PMID:22792189

  16. Preparation of polyethylene sacks for collection of precipitation samples for chemical analysis

    USGS Publications Warehouse

    Schroder, L.J.; Bricker, A.W.

    1985-01-01

    Polyethylene sacks are used to collect precipitation samples. Washing polyethylene with acetone, hexane, methanol, or nitric acid can change the adsorptive characteristics of the polyethylene. In this study, simulated precipitation at pH 4.5 was in contact with the polyethylene sacks for 21 days; subsamples were removed for chemical analysis at 7, 14, and 21 days after intitial contact. Sacks washed with acetone adsorbed iron and lithium; sacks washed with hexane adsorbed barium, iron , and lithium; sacks washed with methanol adsorbed calcium and iron; and sacks washed with 0.30 N nitric acid adsorbed iron. Leaching the plastic sacks with 0.15 N nitric acid did not result in 100-percent recovery of any of the adsorbed metals. Washing polyethylene sacks with dilute nitric acid caused the pH of the simulated precipitation to be decreased by 0.2 pH unit after 1 week of contact with the polyethylene. The specific conductance increased by 10 microsiemens per centimeter. Contamination of precipitation samples by lead was determined to be about 0.1 microgram per liter from contact with precleaned polyethylene sacks. No measurable contamination of precipitation samples by zinc occurred. (USGS)

  17. Volatile organic components of air samples collected from Vertical Launch Missile capsules. Summary report

    SciTech Connect

    Tappan, D.V.; Knight, D.R.; Heyder, E.; Weathersby, P.K.

    1988-09-27

    Gas chromatographic/mass spectroscopic analyses are presented for the volatile organic components found in air samples collected from the inboard vents from Vertical Launch System (VLS) missile capsules aboard a 688 class submarine. Similar analyses were also conducted for a sample of the ship's high pressure air used to fill the missile tubes. A wide variety of organics was detected in the air from the missile capsules; and while no unique components have yet been identified, a significant contribution has been shown to be made by pressure-ventilation of the VLS capsules into the submarine atmosphere which is already heavily laden with volatile organic compounds. The most apparent conclusion from these preliminary analyses is that the mixtures of organic components in the air within VLS missile capsules vary greatly from capsule to capsule (and probably from time to time). Many such samples need to be investigated to provide sufficient information to judge the seriousness of the possibility of venting toxic components into the submarine atmosphere during the maintenance or firing of VLS missiles.

  18. Guidance Regarding Sample Collection and Refinement of Fecal Flotation Exam for the Isolation of Aspiculuris tetraptera.

    PubMed

    Goodroe, Anna E; Baxter, Victoria K; Watson, Julie

    2016-01-01

    Aspiculuris tetraptera continues to be a problem in rodent vivaria, in part due to difficulties in parasite detection. Although PCR testing is highly sensitive, it is expensive and does not always provide immediate results. Consequently, many institutions rely on passive fecal flotation as a quick inhouse exam for diagnosing A. tetraptera infections. To increase the sensitivity of this test, we examined multiple parameters to determine the optimal test protocol. A 30-min soaking period prior to fecal flotation for 15 min allowed fecal pellets to soften and facilitated efficient egg isolation. We also evaluated the effect of time of day, sample size, age, sex, and housing status on egg isolation. No evidence of cyclical egg shedding was found, and although larger fecal sample sizes did not result in more eggs isolated, their use reduced the incidence of false-negative exams. The most eggs were isolated from 8- and 12-wk-old mice, and as mice aged, the number of eggs isolated declined. Overall, neither sex nor housing status influenced the number of eggs isolated. Finally, examination of multiple diagnostic tests (fecal flotation exam, direct examination of cecal and colonic contents, and fecal PCR) revealed that no single test was definitive, thus indicating that multiple tests might be required to successfully screen mice with low pinworm burdens. These findings provide guidance regarding sample selection, collection, and processing to efficiently detect A. tetraptera.

  19. Analytical results from samples collected during coal-bed methane exploration drilling in Caldwell Parish, Louisiana

    USGS Publications Warehouse

    Warwick, Peter D.; Breland, F. Clayton; Hackley, Paul C.; Dulong, Frank T.; Nichols, Douglas J.; Karlsen, Alexander W.; Bustin, R. Marc; Barker, Charles E.; Willett, Jason C.; Trippi, Michael H.

    2006-01-01

    In 2001, and 2002, the U.S. Geological Survey (USGS) and the Louisiana Geological Survey (LGS), through a Cooperative Research and Development Agreement (CRADA) with Devon SFS Operating, Inc. (Devon), participated in an exploratory drilling and coring program for coal-bed methane in north-central Louisiana. The USGS and LGS collected 25 coal core and cuttings samples from two coal-bed methane test wells that were drilled in west-central Caldwell Parish, Louisiana. The purpose of this report is to provide the results of the analytical program conducted on the USGS/LGS samples. The data generated from this project are summarized in various topical sections that include: 1. molecular and isotopic data from coal gas samples; 2. results of low-temperature ashing and X-ray analysis; 3. palynological data; 4. down-hole temperature data; 5. detailed core descriptions and selected core photographs; 6. coal physical and chemical analytical data; 7. coal gas desorption results; 8. methane and carbon dioxide coal sorption data; 9. coal petrographic results; and 10. geophysical logs.

  20. Guidance Regarding Sample Collection and Refinement of Fecal Flotation Exam for the Isolation of Aspiculuris tetraptera

    PubMed Central

    Goodroe, Anna E; Baxter, Victoria K; Watson, Julie

    2016-01-01

    Aspiculuris tetraptera continues to be a problem in rodent vivaria, in part due to difficulties in parasite detection. Although PCR testing is highly sensitive, it is expensive and does not always provide immediate results. Consequently, many institutions rely on passive fecal flotation as a quick inhouse exam for diagnosing A. tetraptera infections. To increase the sensitivity of this test, we examined multiple parameters to determine the optimal test protocol. A 30-min soaking period prior to fecal flotation for 15 min allowed fecal pellets to soften and facilitated efficient egg isolation. We also evaluated the effect of time of day, sample size, age, sex, and housing status on egg isolation. No evidence of cyclical egg shedding was found, and although larger fecal sample sizes did not result in more eggs isolated, their use reduced the incidence of false-negative exams. The most eggs were isolated from 8- and 12-wk-old mice, and as mice aged, the number of eggs isolated declined. Overall, neither sex nor housing status influenced the number of eggs isolated. Finally, examination of multiple diagnostic tests (fecal flotation exam, direct examination of cecal and colonic contents, and fecal PCR) revealed that no single test was definitive, thus indicating that multiple tests might be required to successfully screen mice with low pinworm burdens. These findings provide guidance regarding sample selection, collection, and processing to efficiently detect A. tetraptera. PMID:27657708

  1. Pre-Mission Input Requirements to Enable Successful Sample Collection by a Remote Field/EVA Team

    NASA Technical Reports Server (NTRS)

    Cohen, B. A.; Young, K. E.; Lim, D. S.

    2015-01-01

    objectives than samples collected in the absence of this premission information. We conducted three tests of this hypothesis. Our investigation was designed to document processes, tools and procedures for crew sampling of planetary targets. This is not meant to be a blind, controlled test of crew efficacy, but rather an effort to recognize the relevant variables that enter into sampling protocol and to develop recommendations for crew and backroom training in future endeavors. Methods: One of the primary FINESSE field deployment objectives was to collect impact melt rocks and impact melt-bearing breccias from a number of locations around the WCIS structure to enable high precision geochronology of the crater to be performed [1]. We conducted three tests at WCIS after two full days of team participation in field site activities, including using remote sensing data and geologic maps, hiking overland to become familiar with the terrain, and examining previously-collected samples from other islands. In addition, the team members shared their projects and techniques with the entire team. We chose our "crew members" as volunteers from the team, all of whom had had moderate training in geologic fieldwork and became familiar with the general field setting. The first two tests were short, focused tests of our hypothesis. Test A was to obtain hydrothermal vugs; Test B was to obtain impact melt and intrusive rock as well as the contact between the two to check for contact metamorphism and age differences. In both cases, the test director had prior knowledge of the site geology and had developed a study-specific objective for sampling prior to deployment. Prior to the field deployment, the crewmember was briefed on the sampling objective and the laboratory techniques that would be used on the samples. At the field sites (Fig. 2), the crewmember was given 30 minutes to survey a small section of outcrop (10-15 m) and acquire a suite of three samples. The crewmember talked through his

  2. Temporal and spatial trends of chemical composition of wet deposition samples collected in Austria

    NASA Astrophysics Data System (ADS)

    Schreiner, Elisabeth; Kasper-Giebl, Anne; Lohninger, Hans

    2016-04-01

    Triggered by the occurrence of acid rain a sampling network for the collection of wet deposition samples was initiated in Austria in the early 1980s. Now the data set covers a time period of slightly more than 30 years for the stations being operable since the beginning. Sampling of rain water and snow was and is performed with Wet and Dry Only Samplers (WADOS) on a daily basis. Chemical analysis of rain water and snow samples comprised anions (chloride, nitrate, sulfate) and cations (sodium, ammonium, potassium, calcium and magnesium) as well as pH and electrical conductivity. Here we evaluate and discuss temporal trends of both, ion concentrations and wet deposition data for twelve sampling stations, which were operable for most of the observation period of 30 years. As expected concentrations and wet deposition loads of sulfate and acidity decreased significantly during the last three decades - which is also reflected by a strong decrease of sulfur emissions in Austria and neighboring countries. Regarding nitrate the decrease of concentrations and wet deposition loads is less pronounced. Again this is in accordance with changes in emission data. In case of ammonium even less stations showed a significant decrease of annual average concentrations and depositions. Reasons for that might be twofold. On one hand emissions of ammonia did not decrease as strongly as e.g. sulfur emissions. Furthermore local sources will be more dominant and can influence the year to year variability. Seasonality of ion concentrations and deposition loads were investigated using Fourier analysis. Sulfate, nitrate, ammonium, acidity and also precipitation amount showed characteristic seasonal patterns for most of the sites and for concentrations as well as deposition loads. However the maxima in ion concentrations and deposition loads were observed during different times of the year. Concentrations of basic cations and chloride, on the contrary, hardly showed any seasonality. However, as

  3. Comparison of Toxocara eggs in hair and faecal samples from owned dogs and cats collected in Ankara, Turkey.

    PubMed

    Öge, Hatice; Öge, Semih; Özbakış, Gökben; Gürcan, Safa

    2014-12-15

    This study was undertaken to determine the prevalence of Toxocara eggs on hair and in faeces of healthy owned cats and dogs and to make comparisons between data (sex, age, host factor, etc.) collected from dogs and cats. Toxocara eggs were found on the hair of 14% of 100 dogs and 22% of 100 cats. In total, 58 and 136 eggs were recovered from the hair samples of examined cats and dogs, respectively. Of the total number of eggs, 2 were classified as embryonated in cats. One of the eggs recovered was embryonating in dogs. The maximum number of eggs was found in the tail bottom of cats (28 eggs) and dogs (58 eggs). As well as finding Toxocara eggs in dogs and cats hair, we also found eggs of some helminthic parasites; such as Dicrocoelium sp., Fasciola sp., Taenia sp., Dipylidium caninum and Toxascaris leonina. In addition, faecal samples of same dogs and cats were also examined by two techniques (centrifugal flotation and sedimentation): Toxocara eggs were found in 5% and 13% of dogs and cats faeces, respectively. But, 14% of the dogs and 22% of the cats were positive for Toxocara eggs on hair. The prevalence of eggs in faecal samples was lower than those detected from hair samples (P < 0.05). Two techniques for recovering Toxocara eggs from faecal samples were tested for efficiency and suitability for routine use. The results were expressed as the percentage rate of recovery of Toxocara eggs in positive faecal samples. The recovery rate was better with the method of sedimentation than with the method of flotation (P < 0.05). This study indicates that dogs and cats without internal infections were shown to have eggs on their hair and so uninfected animals also pose a threat in terms of the eggs present on their hair, albeit a small risk.

  4. Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure using a laser sensor

    DOEpatents

    Van Berkel, Gary J [Clinton, TN; Kertesz, Vilmos [Knoxville, TN

    2012-02-21

    A system and method utilizes distance-measuring equipment including a laser sensor for controlling the collection instrument-to-surface distance during a sample collection process for use, for example, with mass spectrometric detection. The laser sensor is arranged in a fixed positional relationship with the collection instrument, and a signal is generated by way of the laser sensor which corresponds to the actual distance between the laser sensor and the surface. The actual distance between the laser sensor and the surface is compared to a target distance between the laser sensor and the surface when the collection instrument is arranged at a desired distance from the surface for sample collecting purposes, and adjustments are made, if necessary, so that the actual distance approaches the target distance.

  5. The Consistency of Isotopologues of Ambient Atmospheric Nitric Acid in Passively Collected Samples

    NASA Astrophysics Data System (ADS)

    Bell, M. D.; Sickman, J. O.; Bytnerowicz, A.; Padgett, P.; Allen, E. B.

    2012-12-01

    Anthropogenic sources of nitrogen oxides have previously been shown to have distinctive isotopic signatures of oxygen and nitrogen. Nylon filters are currently used in passive sampling arrays to measure ambient atmospheric nitric acid concentrations and estimate deposition rates. This experiment measured the ability of nylon filters to consistently collect isotopologues of atmospheric nitric acid in the same ratios as they are present in the atmosphere. Samplers were deployed in continuous stirred tank reactors (CSTR) and at field sites across a nitrogen deposition gradient in Southern California. Filters were exposed over a four week period with individual filters being subjected to 1-4 week exposure times. Extracted nitric acid were measured for δ18O and δ15N ratios and compared for consistency based on length of exposure and amount of HNO3 collected. Filters within the CSTRs collected HNO3 at a consistent rate in both high and low concentration chambers. After two weeks of exposure, the mean δ18O values were within 0.5‰ of the δ18O of the source HNO3 solution. The mean of all weekly exposures were within 0.5‰ of the δ15N of the source solution, but after three weeks, the mean δ15N of adsorbed HNO3 was within 0.2‰. As the length of the exposure increased, the variability of measured delta values decreased for both elements. The field samplers collected HNO3 consistent with previously measured values along a deposition gradient. The mean δ18O at high deposition sites was 52.2‰ compared to 35.7‰ at the low deposition sites. Mean δ15N values were similar at all sites across the deposition gradient. Due to precipitation events occurring during the exposure period, the δ15N and δ18O of nitric acid were highly variable at all field sites. At single sites, changes in δ15N and δ18O were negatively correlated, consistent with two-sourcing mixing dynamics, but the slope of the regressions differed between high and low deposition sites. Anthropogenic

  6. Lessons Learned for Geologic Data Collection and Sampling: Insights from the Desert RATS 2010 Geologist Crewmembers

    NASA Technical Reports Server (NTRS)

    Hurtado, J. M., Jr.; Bleacher, J. E.; Rice, J.; Young, K.; Garry, W. B.; Eppler, D.

    2011-01-01

    Since 1997, Desert Research and Technology Studies (D-RATS) has conducted hardware and operations tests in the Arizona desert that advance human and robotic planetary exploration capabilities. D-RATS 2010 (8/31-9/13) simulated geologic traverses through a terrain of cinder cones, lava flows, and underlying sedimentary units using a pair of crewed rovers and extravehicular activities (EVAs) for geologic fieldwork. There were two sets of crews, each consisting of an engineer/commander and an experienced field geologist drawn from the academic community. A major objective of D-RATS was to examine the functions of a science support team, the roles of geologist crewmembers, and protocols, tools, and technologies needed for effective data collection and sample documentation. Solutions to these problems must consider how terrestrial field geology must be adapted to geologic fieldwork during EVAs

  7. Efficient isolation of multiphoton processes and detection of collective resonances in dilute samples

    NASA Astrophysics Data System (ADS)

    Bruder, Lukas; Binz, Marcel; Stienkemeier, Frank

    2015-11-01

    A phase modulation technique to sensitively and selectively isolate multiple-quantum coherences in a femtosecond pump-probe setup is presented. By detecting incoherent observables and incorporating lock-in amplification, even weak signals of highly dilute samples can be acquired. Applying this method, efficient isolation of one- and two-photon quantum beats in a rubidium-doped helium droplet beam experiment is demonstrated and collective resonances are observed in a potassium vapor for the first time up to fourth order. Our approach provides promising perspectives for coherent time-resolved experiments in the deep UV and multidimensional spectroscopy schemes, in particular when mass-selective detection of particles in dilute gas-phase targets is possible.

  8. Floating sample-collection platform with stage-activated automatic water sampler for streams with large variation in stage

    USGS Publications Warehouse

    Tarte, Stephen R.; Schmidt, A.R.; Sullivan, Daniel J.

    1992-01-01

    A floating sample-collection platform is described for stream sites where the vertical or horizontal distance between the stream-sampling point and a safe location for the sampler exceed the suction head of the sampler. The platform allows continuous water sampling over the entire storm-runoff hydrogrpah. The platform was developed for a site in southern Illinois.

  9. Comparison of glucose determinations on blood samples collected in three types of tubes.

    PubMed

    Li, Geling; Cabanero, Michael; Wang, Zhenglong; Wang, Huiying; Huang, Tao; Alexis, Herol; Eid, Ikram; Muth, Gilad; Pincus, Matthew R

    2013-01-01

    Because of the metabolism of serum glucose in collection tubes containing blood samples, serum glucose levels may be found to decrease over time. Several types of collection tubes have been designed to, at least partially, block glucose metabolism by red blood cells in blood collection tubes that may not be analyzed immediately after blood collection. These include red-top collection tubes with serum separator, grey-top tubes with a fluoride glycolysis inhibitor, and heparin-containing green-top tubes which prevent clot formation. As part of a quality assurance project, we investigated whether glucose levels differed in the three tube types from each of 18 volunteers on a prolonged standing of 4 hours. We then determined the glucose concentrations of all three tubes from each of the 18 volunteers. We used refrigerated samples over a five-day period to determine if the initial values were reproducible. Surprisingly, after standing for four hours at room temperature, we found that the glucose levels in the three tubes from each volunteer were statistically indistinguishable from one another using the two-tailed paired t-test. Also, a linear regression analysis showed that the values of glucose for the three pairs of two tube types were closely correlated with one another, with correlation coefficients of >0.97, slopes close to 1, and Y-intercepts close to 0. These results suggest that blood collection in any of these tubes will render similar values for serum glucose even after standing for four hours. The tubes were then refrigerated at 4°C and re-analyzed after another six hours and then once per day for the next four days. Beginning at the first day at the six-hour determination, the glucose levels in the red- and grey-top tubes were statistically indistinguishable from one another but not in the red- and green-top tubes and in the grey- and green-top tubes. This was due to a steady decrease in the glucose levels in the green-top tubes. The glucose levels in the

  10. Gene Expression Analysis of the Irrigation Solution Samples Collected during Vitrectomy for Idiopathic Epiretinal Membrane

    PubMed Central

    Myojin, Sayaka; Yoshida, Shigeo; Takeda, Atsunobu; Murakami, Yusuke; Kawano, Yoichi; Oshima, Yuji; Ishibashi, Tatsuro; Sonoda, Koh-Hei

    2016-01-01

    Purpose The analysis of gene expression in idiopathic epiretinal membranes (iERMs) may help elucidate ERM formation and its pathology. Here, we conducted a case-control study, in order to determine the expression levels of cytokines and other genes in eyes with macular hole (MH) or iERM. Methods Twenty eyes, obtained from seven male and 13 female patients, were included in the study. The average age of the study subjects was 69.1 ± 7.67 years, and 15 eyes had iERM, while five eyes had MH. Irrigation solution samples were collected during vitrectomy, centrifuged, and the levels of cytokine and other mRNAs in the sediment were assessed using real-time PCR. The expression level of 11 cytokine genes, four transcription factor genes, two cytoskeletal genes, and genes encoding two extracellular matrix proteins in eyes with MH or iERM were determined and compared. Results The expression levels of interleukin 6 (IL6), tumor growth factor B2 (TGFB2), vascular endothelial growth factor A (VEGFA), chemokine C-X-C motif ligand 1 (CXCL1), v-rel avian reticuloendotheliosis viral oncogene homolog A (RELA), glial fibrillary acidic protein (GFAP), and tenascin C (TNC) were significantly higher in eyes with iERM than in eyes with MH. The expression of these genes was not associated with the preoperative visual acuity of the investigated patients. Conclusions The obtained results indicate that real-time PCR analysis of irrigation solution samples collected during vitrectomy can help assess the expression levels of several genes, and that iERM is associated with the expression of pro-inflammatory genes and the genes expressed during angiogenesis and wound healing process (IL6, TGFB2, VEGFA, CXCL1, RELA, GFAP, and TNC). PMID:27736918

  11. Training in metabolomics research. I. Designing the experiment, collecting and extracting samples and generating metabolomics data

    PubMed Central

    Barnes, Stephen; Benton, H. Paul; Casazza, Krista; Cooper, Sara J.; Cui, Xiangqin; Du, Xiuxia; Engler, Jeffrey; Kabarowski, Janusz H.; Li, Shuzhao; Pathmasiri, Wimal; Prasain, Jeevan K.; Renfrow, Matthew B.; Tiwari, Hemant K.

    2016-01-01

    The study of metabolism has had a long history. Metabolomics, a systems biology discipline representing analysis of known and unknown pathways of metabolism, has grown tremendously over the past 20 years. Because of its comprehensive nature, metabolomics requires careful consideration of the question(s) being asked, the scale needed to answer the question(s), collection and storage of the sample specimens, methods for extraction of the metabolites from biological matrices, the analytical method(s) to be employed and the quality control of the analyses, how collected data are correlated, the statistical methods to determine metabolites undergoing significant change, putative identification of metabolites and the use of stable isotopes to aid in verifying metabolite identity and establishing pathway connections and fluxes. The National Institutes of Health Common Fund Metabolomics Program was established in 2012 to stimulate interest in the approaches and technologies of metabolomics. To deliver one of the program’s goals, the University of Alabama at Birmingham has hosted an annual 4-day short course in metabolomics for faculty, postdoctoral fellows and graduate students from national and international institutions. This paper is the first part of a summary of the training materials presented in the course to be used as a resource for all those embarking on metabolomics research. PMID:27434804

  12. Chemical analyses of soil samples collected from the Sandia National Laboratories, New Mexico environs, 1993-2005.

    SciTech Connect

    Deola, Regina Anne; Oldewage, Hans D.; Herrera, Heidi; Miller, Mark Laverne

    2006-03-01

    From 1993 through 2005, the Environmental Management Department of Sandia National Laboratories in Albuquerque, New Mexico (SNL/NM), has collected soil and sediment samples at numerous locations on-site, on the perimeter, and off-site for the purpose of determining potential impacts to the environs from operations at the Laboratories. These samples were submitted to an analytical laboratory for metal-in-soil analyses. Intercomparisons of these results were then made to determine if there was any statistical difference between on-site, perimeter, and off-site samples, or if there were year-to-year increasing or decreasing trends which indicated that further investigation may be warranted. This work provided the SNL Environmental Management Department with a sound baseline data reference against which to assess potential current operational impacts or to compare future operational impacts. In addition, it demonstrates the commitment that the Laboratories have to go beyond mere compliance to achieve excellence in its operations. This data is presented in graphical format with narrative commentaries on particular items of interest.

  13. The cross-sectional GRAS sample: A comprehensive phenotypical data collection of schizophrenic patients

    PubMed Central

    2010-01-01

    Background Schizophrenia is the collective term for an exclusively clinically diagnosed, heterogeneous group of mental disorders with still obscure biological roots. Based on the assumption that valuable information about relevant genetic and environmental disease mechanisms can be obtained by association studies on patient cohorts of ≥ 1000 patients, if performed on detailed clinical datasets and quantifiable biological readouts, we generated a new schizophrenia data base, the GRAS (Göttingen Research Association for Schizophrenia) data collection. GRAS is the necessary ground to study genetic causes of the schizophrenic phenotype in a 'phenotype-based genetic association study' (PGAS). This approach is different from and complementary to the genome-wide association studies (GWAS) on schizophrenia. Methods For this purpose, 1085 patients were recruited between 2005 and 2010 by an invariable team of traveling investigators in a cross-sectional field study that comprised 23 German psychiatric hospitals. Additionally, chart records and discharge letters of all patients were collected. Results The corresponding dataset extracted and presented in form of an overview here, comprises biographic information, disease history, medication including side effects, and results of comprehensive cross-sectional psychopathological, neuropsychological, and neurological examinations. With >3000 data points per schizophrenic subject, this data base of living patients, who are also accessible for follow-up studies, provides a wide-ranging and standardized phenotype characterization of as yet unprecedented detail. Conclusions The GRAS data base will serve as prerequisite for PGAS, a novel approach to better understanding 'the schizophrenias' through exploring the contribution of genetic variation to the schizophrenic phenotypes. PMID:21067598

  14. Automated biowaste sampling system improved feces collection, mass measurement and sampling. [by use of a breadboard model

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Young, R.

    1974-01-01

    The capability of the basic automated Biowaste Sampling System (ABSS) hardware was extended and improved through the design, fabrication and test of breadboard hardware. A preliminary system design effort established the feasibility of integrating the breadboard concepts into the ABSS.

  15. Specific activity and hazards of granite samples collected from the Eastern Desert of Egypt.

    PubMed

    Arafa, Wafaa

    2004-01-01

    Fifty granitic rock samples were collected from different plutons in the central part of the Eastern Desert of Egypt and were analyzed for specific concentrations of (238)U, (232)Th and (40)K radionuclei. The measurements were carried out using a high performance and stability Nomad Plus spectroscopy system attached to a 1.7 keV (FWHM) HPGe detector. The spectra were analyzed using the direct gamma counting comparison method as well as the traditional absolute efficiency curve method. The highest average value of (238)U concentration (1184 Bq kg(-1)) was observed at EI Misikat region whereas the highest average values of (40)K and (232)Th concentration (2301.8 and 162.5 Bq kg(-1) respectively), were detected at Gabal Homret Waggat area. The radium equivalent activity (Ra(eq)), the absorbed dose rate (D), the external hazard index (H(ex)) and the annual gonadal dose equivalent were also calculated and compared to the international recommended values. Radon exhalation rate from the rock samples were measured using the activated charcoal canister method. The average value of radon exhalation varies from 0.052 to 0.69 Bq m(-2) h(-1) and depends on the specific concentration of uranium.

  16. Uranium analysis in some food samples collected from Bathinda area of Punjab, India

    NASA Astrophysics Data System (ADS)

    Kumar, Mukesh; Prasher, Sangeeta; Singh, Surinder

    2009-07-01

    To strengthen the radiation protection infrastructure in Bathinda, the uranium concentration in daily diet of the residents has been measured and its associated radiation risks were estimated for the adult population. Food samples were collected from major cancer prone areas of the district, from which daily diets were prepared. These diet samples were analyzed using fission track technique. The measured values of the uranium content were found to vary from 0.38 mBq/g in mustard seeds to 4.60 mBq/g in wheat. In case of milk the uranium content is found to vary from 28.57-213.36 mBq/ℓ with mean concentration of 61.35 mBq/ℓ. This leads to a daily dietary intake of 0.90 Bq/day. The measured value of 0.90 Bq d-1, contributes to 1.12 mSv to the cumulative effective dose to the population. This dose is much large than the International Commission for Radiological Protection (ICRP) annual effective dose limit of 1 mSv for the general public [1]. Therefore, it would pose significant health hazard.

  17. A microfluidic cigarette smoke collecting platform for simultaneous sample extraction and multiplex analysis.

    PubMed

    Hu, Shan-Wen; Xu, Bi-Yi; Qiao, Shu; Zhao, Ge; Xu, Jing-Juan; Chen, Hong-Yuan; Xie, Fu-Wei

    2016-04-01

    In this work, we report a novel microfluidic gas collecting platform aiming at simultaneous sample extraction and multiplex mass spectrometry (MS) analysis. An alveolar-mimicking elastic polydimethylsiloxane (PDMS) structures was designed to move dynamically driven by external pressure. The movement was well tuned both by its amplitude and rhythm following the natural process of human respiration. By integrating the alveolar units into arrays and assembling them to gas channels, a cyclic contraction/expansion system for gas inhale and exhale was successfully constructed. Upon equipping this system with a droplet array on the alveolar array surface, we were able to get information of inhaled smoke in a new strategy. Here, with cigarette smoke as an example, analysis of accumulation for target molecules during passive smoking is taken. Relationships between the breathing times, distances away from smokers and inhaled content of nicotine are clarified. Further, by applying different types of extraction solvent droplets on different locations of the droplet array, simultaneous extraction of nicotine, formaldehyde and caproic acid in sidestream smoke (SS) are realized. Since the extract droplets are spatially separated, they can be directly analyzed by MS which is fast and can rid us of all complex sample separation and purification steps. Combining all these merits, this small, cheap and portable platform might find wide application in inhaled air pollutant analysis both in and outdoors.

  18. Field guide for collecting and processing stream-water samples for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.

    1994-01-01

    The U.S. Geological Survey's National Water-Quality Assessment program includes extensive data- collection efforts to assess the quality of the Nations's streams. These studies require analyses of stream samples for major ions, nutrients, sediments, and organic contaminants. For the information to be comparable among studies in different parts of the Nation, consistent procedures specifically designed to produce uncontaminated samples for trace analysis in the laboratory are critical. This field guide describes the standard procedures for collecting and processing samples for major ions, nutrients, organic contaminants, sediment, and field analyses of conductivity, pH, alkalinity, and dissolved oxygen. Samples are collected and processed using modified and newly designed equipment made of Teflon to avoid contamination, including nonmetallic samplers (D-77 and DH-81) and a Teflon sample splitter. Field solid-phase extraction procedures developed to process samples for organic constituent analyses produce an extracted sample with stabilized compounds for more accurate results. Improvements to standard operational procedures include the use of processing chambers and capsule filtering systems. A modified collecting and processing procedure for organic carbon is designed to avoid contamination from equipment cleaned with methanol. Quality assurance is maintained by strict collecting and processing procedures, replicate sampling, equipment blank samples, and a rigid cleaning procedure using detergent, hydrochloric acid, and methanol.

  19. Location and Age Database for Selected Foraminifer Samples Collected by Exxon Petroleum Geologists in California

    USGS Publications Warehouse

    Brabb, Earl E.; Parker, John M.

    2003-01-01

    Most of the geologic maps published for central California before 1960 were made without the benefit of age determinations from microfossils. The ages of Cretaceous and Tertiary rocks in the mostly poorly exposed and structurally complex sedimentary rocks represented in the Coast Ranges are critical in determining stratigraphic succession or lack of it, and in determining whether the juxtaposition of similar appearing but different age formations means a fault is present. Since the 1930’s, at least, oil company geologists have used microfossils to assist them in geologic mapping and in determining the environments of deposition of the sediment containing the microfossils. This information has been so confidential that some companies even coded the names of foraminifers to prevent disclosure. In the past 20 years, however, the attitude of petroleum companies about this information has changed, and many of the formerly confidential materials and reports are now available. We report here on 1,964 Exxon foraminifer samples mostly from surface localities in the San Francisco Bay region, and elsewhere in California. Most but not all the samples were plotted on U. S. Geological Survey (USGS) 7.5’ topographic maps or on obsolete USGS 15’ maps. The information from the slides can be used to update geologic maps prepared without the benefit of microfossil data, to analyze the depth and temperature of ocean water covering parts of California during the Mesozoic and Cenozoic Eras, and for solving nomenclature and other scientific problems. A similar report on more than 30,000 slides for surface samples collected by Chevron geologists has been released (Brabb and Parker, 2003), and another report provides information on slides for more than 2000 oil test wells in Northern California (Brabb, Powell, and Brocher, 2001).

  20. Antibiotic resistance among bacteria isolated from seawater and penguin fecal samples collected near Palmer Station, Antarctica.

    PubMed

    Miller, Robert V; Gammon, Katharine; Day, Martin J

    2009-01-01

    Antibiotic resistance in aquatic bacteria has increased steadily as a consequence of the widespread use of antibiotics, but practice and international treaty should have limited antibiotic contamination in Antarctica. We estimated antibiotic resistance in microorganisms isolated from the Antarctic marine waters and a penguin rookery, for 2 reasons: (i) as a measure of human impact and (ii) as a potential "snapshot" of the preantibiotic world. Samples were taken at 4 established sampling sites near Palmer Station, which is situated at the southern end of the Palmer Archipelago (64 degrees 10'S, 61 degrees 50'W). Sites were chosen to provide different potentials for human contamination. Forty 50 mL samples of seawater were collected and colony-forming units (CFU)/mL were determined at 6 and 20 degrees C. For this study, presumed psychrophiles (growth at 6 degrees C) were assumed to be native to Antarctic waters, whereas presumed mesophiles (growth at 20 degrees C but not at 6 degrees C) were taken to represent introduced organisms. The 20-6 degrees C CFU/mL ratio was used as a measure of the relative impact to the ecosystem of presumably introduced organisms. This ratio was highest at the site nearest to Palmer Station and decreased with distance from it, suggesting that human presence has impacted the natural microbial flora of the site. The frequency of resistance to 5 common antibiotics was determined in each group of isolates. Overall drug resistance was higher among the presumed mesophiles than the presumed psychrophiles and increased with proximity to Palmer Station, with the presumed mesophiles showing higher frequencies of single and multiple drug resistance than the psychrophile population. The frequency of multidrug resistance followed the same pattern. It appears that multidrug resistance is low among native Antarctic bacteria but is increased by human habitation.

  1. Reproducibility of expired breath hydrogen levels in the neonate: a comparison of two methods for sample collection.

    PubMed

    Broadbent, R; Robb, T A; Davidson, G P

    1983-02-07

    We have compared a nasopharyngeal catheter method for breath sampling and a valved collection device. Sample quality was assessed by simultaneous oxygen measurement and reproducibility was checked by the analysis of 50 pairs of samples from four premature neonates. Both collection methods produced samples of highly variable quality suggesting a variable mixture of alveolar and non-alveolar air as well as differences in expired oxygen levels between babies. The mean oxygen levels were similar for both sampling techniques. Linear regression analysis of paired hydrogen results showed a highly significant correlation coefficient r = 0.73. This was improved markedly to r = 0.94 by normalization of hydrogen values based on observed oxygen levels, and so supports the earlier article by Robb and Davidson [1]. All breath hydrogen analyses require a measure of sample quality. Reproducible results and meaningful changes in hydrogen concentration in breath samples can only be achieved by correction according to sample quality. Correction to a common oxygen value should allow quantitative comparisons between patients. Samples were best collected from neonates by the nasopharyngeal catheter method, which least disturbed the patient, allowed multiple sample collection and gave lower oxygen and higher hydrogen values where large differences between pairs occurred.

  2. Geochemical results from stream-water and stream-sediment samples collected in Colorado and New Mexico

    USGS Publications Warehouse

    Hageman, Philip L.; Todd, Andrew S.; Smith, Kathleen S.; DeWitt, Ed; Zeigler, Mathew P.

    2013-01-01

    Scientists from the U.S. Geological Survey are studying the relationship between watershed lithology and stream-water chemistry. As part of this effort, 60 stream-water samples and 43 corresponding stream-sediment samples were collected in 2010 and 2011 from locations in Colorado and New Mexico. Sample sites were selected from small to midsize watersheds composed of a high percentage of one rock type or geologic unit. Stream-water and stream-sediment samples were collected, processed, preserved, and analyzed in a consistent manner. This report releases geochemical data for this phase of the study.

  3. Additional variability at the D12S391 STR locus in an Austrian population sample: sequencing data and allele distribution.

    PubMed

    Glock, B; Dauber, E M; Schwartz, D W; Mayr, W R

    1997-12-01

    The highly polymorphic STR locus D12S391 was investigated in an Austrian population sample (N = 150) by PCR-amplification, comparative detection on native and denaturing polyacrylamide gels and solid phase single stranded sequencing of three size variant alleles and several additional alleles. A total of 15 alleles, distinguishable by size under denaturing conditions, could be detected. No deviations from Hardy-Weinberg equilibrium were observed in the population investigated (P = 0.52). Sequencing of size variants designated 17.3 and 18.3 showed an incomplete (GAT) repeat unit at position two of the tandem region. Additional new sequence variants due to varying compositions of the number of (AGAT) and (AGAC) repeats could be identified. Due to distinct electrophoretical mobilities of alleles of the same size but different sequence structures, denaturing detection conditions should be employed when the aim is standardization.

  4. Variation in aluminum, iron, and particle concentrations in oxic ground-water samples collected by use of tangential-flow ultrafiltration with low-flow sampling

    USGS Publications Warehouse

    Szabo, Z.; Oden, J.H.; Gibs, J.; Rice, D.E.; Ding, Y.; ,

    2001-01-01

    Particulates that move with ground water and those that are artificially mobilized during well purging could be incorporated into water samples during collection and could cause trace-element concentrations to vary in unfiltered samples, and possibly in filtered samples (typically 0.45-um (micron) pore size) as well, depending on the particle-size fractions present. Therefore, measured concentrations may not be representative of those in the aquifer. Ground water may contain particles of various sizes and shapes that are broadly classified as colloids, which do not settle from water, and particulates, which do. In order to investigate variations in trace-element concentrations in ground-water samples as a function of particle concentrations and particle-size fractions, the U.S. Geological Survey, in cooperation with the U.S. Air Force, collected samples from five wells completed in the unconfined, oxic Kirkwood-Cohansey aquifer system of the New Jersey Coastal Plain. Samples were collected by purging with a portable pump at low flow (0.2-0.5 liters per minute and minimal drawdown, ideally less than 0.5 foot). Unfiltered samples were collected in the following sequence: (1) within the first few minutes of pumping, (2) after initial turbidity declined and about one to two casing volumes of water had been purged, and (3) after turbidity values had stabilized at less than 1 to 5 Nephelometric Turbidity Units. Filtered samples were split concurrently through (1) a 0.45-um pore size capsule filter, (2) a 0.45-um pore size capsule filter and a 0.0029-um pore size tangential-flow filter in sequence, and (3), in selected cases, a 0.45-um and a 0.05-um pore size capsule filter in sequence. Filtered samples were collected concurrently with the unfiltered sample that was collected when turbidity values stabilized. Quality-assurance samples consisted of sequential duplicates (about 25 percent) and equipment blanks. Concentrations of particles were determined by light scattering

  5. Adaptive free energy sampling in multidimensional collective variable space using boxed molecular dynamics.

    PubMed

    O'Connor, Mike; Paci, Emanuele; McIntosh-Smith, Simon; Glowacki, David R

    2016-12-22

    The past decade has seen the development of a new class of rare event methods in which molecular configuration space is divided into a set of boundaries/interfaces, and then short trajectories are run between boundaries. For all these methods, an important concern is how to generate boundaries. In this paper, we outline an algorithm for adaptively generating boundaries along a free energy surface in multi-dimensional collective variable (CV) space, building on the boxed molecular dynamics (BXD) rare event algorithm. BXD is a simple technique for accelerating the simulation of rare events and free energy sampling which has proven useful for calculating kinetics and free energy profiles in reactive and non-reactive molecular dynamics (MD) simulations across a range of systems, in both NVT and NVE ensembles. Two key developments outlined in this paper make it possible to automate BXD, and to adaptively map free energy and kinetics in complex systems. First, we have generalized BXD to multidimensional CV space. Using strategies from rigid-body dynamics, we have derived a simple and general velocity-reflection procedure that conserves energy for arbitrary collective variable definitions in multiple dimensions, and show that it is straightforward to apply BXD to sampling in multidimensional CV space so long as the Cartesian gradients ∇CV are available. Second, we have modified BXD to undertake on-the-fly statistical analysis during a trajectory, harnessing the information content latent in the dynamics to automatically determine boundary locations. Such automation not only makes BXD considerably easier to use; it also guarantees optimal boundaries, speeding up convergence. We have tested the multidimensional adaptive BXD procedure by calculating the potential of mean force for a chemical reaction recently investigated using both experimental and computational approaches - i.e., F + CD3CN → DF + D2CN in both the gas phase and a strongly coupled explicit CD3CN solvent

  6. Variation in aluminum, iron, and particle concentrations in oxic groundwater samples collected by use of tangential-flow ultrafiltration with low-flow sampling

    NASA Astrophysics Data System (ADS)

    Szabo, Zoltan; Oden, Jeannette H.; Gibs, Jacob; Rice, Donald E.; Ding, Yuan

    2002-02-01

    Particulates that move with ground water and those that are artificially mobilized during well purging could be incorporated into water samples during collection and could cause trace-element concentrations to vary in unfiltered samples, and possibly in filtered samples (typically 0.45-um (micron) pore size) as well, depending on the particle-size fractions present. Therefore, measured concentrations may not be representative of those in the aquifer. Ground water may contain particles of various sizes and shapes that are broadly classified as colloids, which do not settle from water, and particulates, which do. In order to investigate variations in trace-element concentrations in ground-water samples as a function of particle concentrations and particle-size fractions, the U.S. Geological Survey, in cooperation with the U.S. Air Force, collected samples from five wells completed in the unconfined, oxic Kirkwood-Cohansey aquifer system of the New Jersey Coastal Plain. Samples were collected by purging with a portable pump at low flow (0.2-0.5 liters per minute and minimal drawdown, ideally less than 0.5 foot). Unfiltered samples were collected in the following sequence: (1) within the first few minutes of pumping, (2) after initial turbidity declined and about one to two casing volumes of water had been purged, and (3) after turbidity values had stabilized at less than 1 to 5 Nephelometric Turbidity Units. Filtered samples were split concurrently through (1) a 0.45-um pore size capsule filter, (2) a 0.45-um pore size capsule filter and a 0.0029-um pore size tangential-flow filter in sequence, and (3), in selected cases, a 0.45-um and a 0.05-um pore size capsule filter in sequence. Filtered samples were collected concurrently with the unfiltered sample that was collected when turbidity values stabilized. Quality-assurance samples consisted of sequential duplicates (about 25 percent) and equipment blanks. Concentrations of particles were determined by light scattering.

  7. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF FOOD PREPARATION SURFACE WIPE SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.17)

    EPA Science Inventory

    This SOP describes the method for collection of the food preparation surface wipe samples for the measurement of persistent organic pollutants (POP). This method uses a wipe to collect POP residues from a surface where a study participant prepares food the most often (i.e., kitch...

  8. New Staphylinidae (Coleoptera) records with new collection data from New Brunswick and an addition to the fauna of Quebec: Staphylininae

    PubMed Central

    Webster, Reginald P.; Smetana, Aleš; Sweeney, Jon D.; DeMerchant, Ian

    2012-01-01

    Abstract Forty-four species of Staphylininae are newly reported from New Brunswick, bringing the total number of species known from the province to 126. Quedius criddlei (Casey) is reported for the first time from Quebec. Bisnius cephalotes (Gravenhorst) is removed from the faunal list of New Brunswick due to a lack of supporting voucher specimens. Additional locality data are presented for seven species either recently recorded from the province or with few previous records and little habitat data. We provide the first documented records of Atrecus americanus (Casey), Quedius erythrogaster Mannerheim, Quedius labradorensis labradorensis Smetana, Quedius plagiatus (Mannerheim), and Neobisnius terminalis (LeConte) from New Brunswick. Collection and habitat data are presented and discussed for all species. PMID:22577325

  9. Mercury speciation in wet deposition samples collected from a coastal area of Minamata Bay

    NASA Astrophysics Data System (ADS)

    Marumoto, Kohji; Matsuyama, Akito

    2014-04-01

    To better understand the methylation and demethylation of mercury (Hg) in the atmosphere, monomethyl mercury (MMHg) concentrations in wet deposition samples collected in the Minamata Bay area from September, 2009 to August, 2010 were determined. The concentrations of total Hg (dissolved Hg + particulate Hg) and dissolved reactive Hg were also measured. The volume-weighted mean concentrations of dissolved MMHg and total Hg were 0.061 and 5.9 ng L-1, respectively. Almost 90% of total Hg was in the dissolved phase and dissolved reactive Hg was the dominant Hg species in the wet deposition. The wet deposition fluxes of total Hg and reactive Hg increased in the rainy season (summer and fall), while the concentrations and wet deposition fluxes of MMHg were higher in winter and spring than in summer. Factors affecting this seasonal variation of MMHg were also considered. The MMHg in wet depositions may be decomposed by the increased levels of UV radiation in summer months, although MMHg can also be emitted from anthropogenic and biogenic sources and/or produced by photochemical reactions. Long-range transport from the Asian continent may also contribute to the seasonal variation of the wet MMHg deposition flux.

  10. Collection and processing of plant, animal and soil samples from Bikini, Enewetak and Rongelap Atolls

    SciTech Connect

    Stuart, M.L.

    1995-09-01

    The United States used the Marshall Islands for its nuclear weapons program testing site from 1946 to 1958. The BRAVO test was detonated at Bikini Atoll on March 1, 1954. Due to shifting wind conditions at the time of the nuclear detonation, many of the surrounding Atolls became contaminated with fallout (radionuclides carried by the wind currents). Lawrence Livermore National Laboratory`s (LLNL) Marshall Islands Project has been responsible for the collecting, processing, and analyzing of food crops, vegetation, soil, water, animals, and marine species to characterize the radionuclides in the environment, and to estimate dose at atolls that may have been contaminated. Tropical agriculture experiments reducing the uptake of {sup 137}Cs have been conducted on Bikini Atoll. The Marshall Islands field team and laboratory processing team play an important role in the overall scheme of the Marshall Islands Dose Assessment and Radioecology Project. This report gives a general description of the Marshall Islands field sampling and laboratory processing procedures currently used by our staff.

  11. Radiometric assessment of natural radioactivity levels of agricultural soil samples collected in Dakahlia, Egypt.

    PubMed

    Issa, Shams A M

    2013-01-01

    Determination of the natural radioactivity has been carried out, by using a gamma-ray spectrometry [NaI (Tl) 3″ × 3″] system, in surface soil samples collected from various locations in Dakahlia governorate, Egypt. These locations form the agriculturally important regions of Egypt. The study area has many industries such as chemical, paper, organic fertilisers and construction materials, and the soils of the study region are used as a construction material. Therefore, it becomes necessary to study the natural radioactivity levels in soil to assess the dose for the population in order to know the health risks. The activity concentrations of (226)Ra, (232)Th and (40)K in the soil ranged from 5.7 ± 0.3 to 140 ± 7, from 9.0 ± 0.4 to 139 ± 7 and from 22 ± 1 to 319 ± 16 Bq kg(-1), respectively. The absorbed dose rate, annual effective dose rate, radium equivalent (Req), excess lifetime cancer risk, hazard indices (Hex and Hin) and annual gonadal dose equivalent, which resulted from the natural radionuclides in the soil were calculated.

  12. Dynamic simulation tools for the analysis and optimization of novel collection, filtration and sample preparation systems

    SciTech Connect

    Clague, D; Weisgraber, T; Rockway, J; McBride, K

    2006-02-12

    The focus of research effort described here is to develop novel simulation tools to address design and optimization needs in the general class of problems that involve species and fluid (liquid and gas phases) transport through sieving media. This was primarily motivated by the heightened attention on Chem/Bio early detection systems, which among other needs, have a need for high efficiency filtration, collection and sample preparation systems. Hence, the said goal was to develop the computational analysis tools necessary to optimize these critical operations. This new capability is designed to characterize system efficiencies based on the details of the microstructure and environmental effects. To accomplish this, new lattice Boltzmann simulation capabilities where developed to include detailed microstructure descriptions, the relevant surface forces that mediate species capture and release, and temperature effects for both liquid and gas phase systems. While developing the capability, actual demonstration and model systems (and subsystems) of national and programmatic interest were targeted to demonstrate the capability. As a result, where possible, experimental verification of the computational capability was performed either directly using Digital Particle Image Velocimetry or published results.

  13. Simultaneous quantification of stevioside and rebaudioside A in different stevia samples collected from the Indian subcontinent

    PubMed Central

    Chester, Karishma; Tamboli, Ennus T.; Singh, Mhaveer; Ahmad, Sayeed

    2012-01-01

    Background: A high performance thin layer chromatographic (HPTLC) method was developed for simultaneous estimation of stevioside and rebaudioside A in Stevia rebaudiana samples collected from different regions of Indian subcontinent. Materials and Methods: The separation was achieved by using acetone: ethyl acetate: water (5:4:1, v/v/v) as the solvent system on precoated silica gel 60 F254 TLC plates. The densitometric quantification of stevia glycosides was carried out at wavelength 360 nm in absorption mode after spraying with anisaldehyde sulphuric acid as detecting reagent. Results: The well resolved peaks for stevioside and rebaudioside A were observed at Rf values 0.31± 0.02 and 0.21± 0.02 respectively. The calibration curves were found linear with a wide range of concentration 100 - 2000 ng spot-1 with good correlation coefficient 0.996 and 0.991 for stevioside and rebaudioside A, respectively. Conclusions: The proposed method was validated as per the ICH (International Conferences on Harmonization) guidelines and found simple, sensitive, economic, reproducible, robust and accurate for quantitative analysis of stevia glycosides, which can be applied for quality control of stevia as well as to check. PMID:23248559

  14. Distribution of vibrio species in shellfish and water samples collected from the atlantic coastline of south-east Nigeria.

    PubMed

    Eyisi, Onyedikachukwu A L; Nwodo, Uchechukwu U; Iroegbu, Christian U

    2013-09-01

    Crayfish, lobster, and sea-water samples collected from five fishing islands on the Atlantic coast-Bight of Biafra (Bonny)-belonging to Ibaka Local Government Area of Akwa-Ibom State of Nigeria were bacteriologically evaluated on thiosulphate citrate bile-salt sucrose (TCBS) agar for Vibrio load and pathotypes. Mean log10 Vibrio counts of 7.64+/-2.78 cfu/g (in crayfish), 5.07+/-3.21 cfu/g (in lobster), and 3.06+/-2.27 cfu/mL (in sea-water) were obtained in rainy season (June-July) while counts in the dry season (November-December) were 6.25+/-1.93 cfu/g, 5.99+/-1.54 cfu/g, and 3.84+/-1.78 cfu/mL respectively. The physicochemical measurements (temperature, pH, and total dissolved solutes) of the sea-water did not vary significantly in the two seasons across all five islands. Vibrio species isolated were Vibrio cholerae (both O1 and non-O1 serotypes), V parahaemolyticus, V vulnificus, V mimicus, and V fluvialis. Both Ogawa and Inaba subtypes of V cholerae O1 serotype were found. In addition, the Hikojima subtype, which had not been previously reported in the region, was isolated in two samples. The results show that these Vibrio species are endemic in the area.

  15. Variability of Organophosphorous Pesticide Metabolite Levels in Spot and 24-hr Urine Samples Collected from Young Children during 1 Week

    PubMed Central

    Kogut, Katherine; Eisen, Ellen A.; Jewell, Nicholas P.; Quirós-Alcalá, Lesliam; Castorina, Rosemary; Chevrier, Jonathan; Holland, Nina T.; Barr, Dana Boyd; Kavanagh-Baird, Geri; Eskenazi, Brenda

    2012-01-01

    Background: Dialkyl phosphate (DAP) metabolites in spot urine samples are frequently used to characterize children’s exposures to organophosphorous (OP) pesticides. However, variable exposure and short biological half-lives of OP pesticides could result in highly variable measurements, leading to exposure misclassification. Objective: We examined within- and between-child variability in DAP metabolites in urine samples collected during 1 week. Methods: We collected spot urine samples over 7 consecutive days from 25 children (3–6 years of age). On two of the days, we collected 24-hr voids. We assessed the reproducibility of urinary DAP metabolite concentrations and evaluated the sensitivity and specificity of spot urine samples as predictors of high (top 20%) or elevated (top 40%) weekly average DAP metabolite concentrations. Results: Within-child variance exceeded between-child variance by a factor of two to eight, depending on metabolite grouping. Although total DAP concentrations in single spot urine samples were moderately to strongly associated with concentrations in same-day 24-hr samples (r ≈ 0.6–0.8, p < 0.01), concentrations in spot samples collected > 1 day apart and in 24-hr samples collected 3 days apart were weakly correlated (r ≈ –0.21 to 0.38). Single spot samples predicted high (top 20%) and elevated (top 40%) full-week average total DAP excretion with only moderate sensitivity (≈ 0.52 and ≈ 0.67, respectively) but relatively high specificity (≈ 0.88 and ≈ 0.78, respectively). Conclusions: The high variability we observed in children’s DAP metabolite concentrations suggests that single-day urine samples provide only a brief snapshot of exposure. Sensitivity analyses suggest that classification of cumulative OP exposure based on spot samples is prone to type 2 classification errors. PMID:23052012

  16. Airborne Detection and Quantification of Swine Influenza A Virus in Air Samples Collected Inside, Outside and Downwind from Swine Barns

    PubMed Central

    Corzo, Cesar A.; Culhane, Marie; Dee, Scott; Morrison, Robert B.; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m3 of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m3 of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m3. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions. PMID:23951164

  17. Results of chemical and stable isotopic analyses of water samples collected in the Patagonia Mountains, southern Arizona

    USGS Publications Warehouse

    Wanty, Richard B.; Shanks, Wayne C.; Lamothe, Paul; Meier, A.L.; Lichte, Fred; Briggs, Paul H.; Berger, Byron R.

    2001-01-01

    Water samples were collected in the Patagonia Mountains in February, 1997. Most of the samples were collected from portals of abandoned mines, or from stream drainages immediately downstream from abandoned mines. Most of the samples have low pH ( 1000 mg/L). Anion composition of the water samples is dominated by sulfate, while cation compositions range from calcium-dominated to mixed calcium-magnesium or calcium-sodium-dominated waters. Metals such as iron, manganese, copper, zinc, and aluminum contribute a significant portion (>10%) of the cation content to the water samples. Because of the low pH?s, protons contribute up to several percent of the cation character of the waters in some of the samples. The data are presented in tabular and graphical formats, with descriptions of data quality and brief descriptions of results.

  18. (Collection of North Pacific Ocean surface seawater samples from a container ship): Foreign trip report, January 24--March 4, 1989

    SciTech Connect

    Goddard, J.G.

    1989-03-16

    This trip was a continuation of the sampling program undertaken during 1984--1985 to study the seasonal and regional variability of CO/sub 2/ chemistry in high-latitude deep water formation areas of the North Pacific. The work is conducted by Columbia University (Dr. Taro Takahashi, Principal Investigator) for the Department of Energy's Energy Systems Program managed by Oak Ridge National Laboratory. Aboard the President Eisenhower, we collected surface seawater samples at forty-two stations along the route from Oakland, California, to Keelung, Taiwan, via Guam. On the return trip, samples were collected from thirty-nine stations during transit from Kaohsiung, Taiwan, to Los Angeles, California.

  19. (Collection of North Pacific Ocean surface seawater samples for chemical analysis): Foreign trip report, January 26--February 27, 1988

    SciTech Connect

    Goddard, J.G.

    1988-03-04

    This trip was a continuation of the sampling program undertaken during 1984--1985 to study the seasonal and regional variability of CO/sub 2/ chemistry in high latitude deep water formation areas of the North Pacific. The work is conducted by Columbia University (Dr. Taro Takahashi, Principal Investigator) for the Department of Energy's Energy Systems Program managed by Oak Ridge National Laboratory. Aboard the PRESIDENT ARTHUR, surface seawater samples were collected at forty-one stations along the route from Oakland, California, to Keeling, Taiwan, via Guam. On the return trip, samples were collected from thirty-seven stations during transit from Keelung to Los Angeles, California.

  20. Brevibacillus halotolerans sp. nov., isolated from saline soil sample collected from paddy field.

    PubMed

    Song, Jinlong; Wang, Yanwei; Song, Yi; Zhao, Bingqiang; Wang, Huimin; Zhou, Shan; Kong, Delong; Guo, Xiang; Li, Yanting; He, Mingxiong; Ma, Kedong; Ruan, Zhiyong; Yan, Yanchun

    2016-10-17

    Two novel aerobic bacteria, designated strains LAM0312T and LAM0313, were isolated from saline soil sample collected from paddy field in Dezhou city, Shandong Province in China. The Cells of these strains were Gram-stain positive, sporogenous, rod-shaped and motile with peritrichous flagella. The optimal growth temperature and pH were 30 ºC and pH 7.0-8.0, repesctively. Strain LAM0312T was found to be able to grow in the presence of 12 % (w/v) NaCl. The major fatty acids of strains were identified as anteiso-C15:0 and iso-C15:0. The dominant polar lipids were diphosphatidylglycerol, phosphatidylethanolamine, phosphatidylglycerol, glycolipids, five unidentitied lipids and phosphatidylmonomethylethanolamine. The cell wall peptidoglycan was found to contain meso-diaminopimelic acid. The predominant menaquinone was identified as menaquinone-7. The G+C content of genomic DNA of strains LAM0312T and LAM0313 were 45.0 mol% and 46.0 mol%, respectively as determined by the Tm method. The 16S rRNA gene sequence similarity analysis indicated that the strains were closely related to Brevibacillus laterosporus DSM 25T and Brevibacillus fluminis JCM 15716T with 98.5 % and 96.4 % sequence similarity, respectively. The DNA-DNA hybridization values between strain LAM0312T and LAM0313 was 92 ± 0.6 % (reciprocal 90 ± 0.2 %)and the value between LAM0312T andBrevibacillus laterosporus DSM 25T was 48 ± 0.5 % (reciprocal 40 ± 0.4 %). On the basis of the phenotypic, phylogenetic and chemotaxonomic characteristics, the strains are proposed to represent a novel species of the genus Brevibacillus, for which the name Brevibacillus halotolerans sp. nov. is proposed. The type strain is LAM0312T (=ACCC 06527T =JCM 30849T).

  1. Towards a phylogenetic generic classification of Thelypteridaceae: Additional sampling suggests alterations of neotropical taxa and further study of paleotropical genera.

    PubMed

    Almeida, Thaís Elias; Hennequin, Sabine; Schneider, Harald; Smith, Alan R; Batista, João Aguiar Nogueira; Ramalho, Aline Joseph; Proite, Karina; Salino, Alexandre

    2016-01-01

    Thelypteridaceae is one of the largest fern families, having about 950 species and a cosmopolitan distribution but with most species occurring in tropical and subtropical regions. Its generic classification remains controversial, with different authors recognizing from one up to 32 genera. Phylogenetic relationships within the family have not been exhaustively studied, but previous studies have confirmed the monophyly of the lineage. Thus far, sampling has been inadequate for establishing a robust hypothesis of infrafamilial relationships within the family. In order to understand phylogenetic relationships within Thelypteridaceae and thus to improve generic reclassification, we expand the molecular sampling, including new samples of Old World taxa and, especially, many additional neotropical representatives. We also explore the monophyly of exclusively or mostly neotropical genera Amauropelta, Goniopteris, Meniscium, and Steiropteris. Our sampling includes 68 taxa and 134 newly generated sequences from two plastid genomic regions (rps4-trnS and trnL-trnF), plus 73 rps4 and 72 trnL-trnF sequences from GenBank. These data resulted in a concatenated matrix of 1980 molecular characters for 149 taxa. The combined data set was analyzed using maximum parsimony and bayesian inference of phylogeny. Our results are consistent with the general topological structure found in previous studies, including two main lineages within the family: phegopteroid and thelypteroid. The thelypteroid lineage comprises two clades; one of these included the segregates Metathelypteris, Coryphopteris, and Amauropelta (including part of Parathelypteris), whereas the other comprises all segregates of Cyclosorus s.l., such as Goniopteris, Meniscium, and Steiropteris (including Thelypteris polypodioides, previously incertae sedis). The three mainly neotropical segregates were found to be monophyletic but nested in a broadly defined Cyclosorus. The fourth mainly neotropical segregate, Amauropelta

  2. Purposeful Sampling for Qualitative Data Collection and Analysis in Mixed Method Implementation Research.

    PubMed

    Palinkas, Lawrence A; Horwitz, Sarah M; Green, Carla A; Wisdom, Jennifer P; Duan, Naihua; Hoagwood, Kimberly

    2015-09-01

    Purposeful sampling is widely used in qualitative research for the identification and selection of information-rich cases related to the phenomenon of interest. Although there are several different purposeful sampling strategies, criterion sampling appears to be used most commonly in implementation research. However, combining sampling strategies may be more appropriate to the aims of implementation research and more consistent with recent developments in quantitative methods. This paper reviews the principles and practice of purposeful sampling in implementation research, summarizes types and categories of purposeful sampling strategies and provides a set of recommendations for use of single strategy or multistage strategy designs, particularly for state implementation research.

  3. Euromet-A Programme for the Collection of New Extraterrestrial Samples: Progress, Plans, or Pipe-Dreams?

    NASA Astrophysics Data System (ADS)

    Pillinger, C. T.

    1992-07-01

    EUROMET came into being in the wake of the Meteoritical Society Conference held in Vienna in 1989. It is now funded by the European Community Science Programme (Contract No. SC1* - CT91- 0618 (SSMA)) until November 1993, to collect and curate new meteorites and cosmic dust and distribute samples of the material on a worldwide basis. Although the progress towards fully operational status may seem slow, a great many people have contributed substantial amounts of time and effort to establishing a many-faceted project. EUROMET has held three very successful field expeditions to the Frontier Mountains (courtesy of the Italian Progetto Antartide), Dumont d'Urville together with Expeditions Polaires Francaises; Terres Australes et Antarctiques Francaises, and to the Nullarbor Plain (in conjunction with Dr. Alex Bevan, Western Australian Museum WAMET). The curatorial responsibilities extend to over 900 meteorite specimens and in excess of 10,000 cosmic dust grains. More information about these collections is provided elsewhere (several abstracts, this volume) with future updates to be published in the Meteoritical Bulletin. An electronic newsletter will be coming on line for rapid dissemination of information concerning sample characterisation and availability. Information regarding submission of sample requests can be found published in Meteoritics 27, 110 (1992). The EUROMET Council is actively pursuing a number of possibilities to ensure a long-term commitment to meteorite and micrometeorite recovery. Although many of the plans are still tentative they are moving towards fruition. Future Antarctic activities will hopefully include a 1992/3 mission to Frontier Mountains and other locations in Victoria Land and a more sophisticated cosmic dust factory (1994/5) with sponsors as before. Additionally we are exploring the possibility of a joint EUROMET/Indian expedition to Wohlthat Massif, which will be followed up via the German Georg Forster base in conjunction with Ganovex

  4. 9 CFR 147.12 - Procedures for collection, isolation, and identification of Salmonella from environmental samples...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... premises. Disposable caps should be provided and discarded after use on each premises. After collection... retaining the upper half for future disposal. Replace the cap on the inoculated tube and continue the... transport them, on ice or otherwise refrigerated, to a laboratory within 48 hours of collection. The...

  5. 9 CFR 147.12 - Procedures for collection, isolation, and identification of Salmonella from environmental samples...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... premises. Disposable caps should be provided and discarded after use on each premises. After collection... retaining the upper half for future disposal. Replace the cap on the inoculated tube and continue the... transport them, on ice or otherwise refrigerated, to a laboratory within 48 hours of collection. The...

  6. 9 CFR 147.12 - Procedures for collection, isolation, and identification of Salmonella from environmental samples...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... premises. Disposable caps should be provided and discarded after use on each premises. After collection... retaining the upper half for future disposal. Replace the cap on the inoculated tube and continue the... transport them, on ice or otherwise refrigerated, to a laboratory within 48 hours of collection. The...

  7. 9 CFR 147.12 - Procedures for collection, isolation, and identification of Salmonella from environmental samples...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... premises. Disposable caps should be provided and discarded after use on each premises. After collection... retaining the upper half for future disposal. Replace the cap on the inoculated tube and continue the... transport them, on ice or otherwise refrigerated, to a laboratory within 48 hours of collection. The...

  8. 9 CFR 147.12 - Procedures for collection, isolation, and identification of Salmonella from environmental samples...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... premises. Disposable caps should be provided and discarded after use on each premises. After collection... retaining the upper half for future disposal. Replace the cap on the inoculated tube and continue the... transport them, on ice or otherwise refrigerated, to a laboratory within 48 hours of collection. The...

  9. MACRO- MICRO-PURGE SOIL GAS SAMPLING METHODS FOR THE COLLECTION OF CONTAMINANT VAPORS

    EPA Science Inventory

    Purging influence on soil gas concentrations for volatile organic compounds (VOCs), as affected by sampling tube inner diameter and sampling depth (i.e., dead-space purge volume), was evaluated at different field sites. A macro-purge sampling system consisted of a standard hollo...

  10. Sample Collection from Small Airless Bodies: Examination of Temperature Constraints for the TGIP Sample Collector for the Hera Near-Earth Asteroid Sample Return Mission

    NASA Technical Reports Server (NTRS)

    Franzen, M. A.; Roe, L. A.; Buffington, J. A.; Sears, D. W. G.

    2005-01-01

    There have been a number of missions that have explored the solar system with cameras and other instruments but profound questions remain that can only be addressed through the analysis of returned samples. However, due to lack of appropriate technology, high cost, and high risk, sample return has only recently become a feasible part of robotic solar system exploration. One specific objective of the President s new vision is that robotic exploration of the solar system should enhance human exploration as it discovers and understands the the solar system, and searches for life and resources [1]. Missions to small bodies, asteroids and comets, will partially fill the huge technological void between missions to the Moon and missions to Mars. However, such missions must be low cost and inherently simple, so they can be applied routinely to many missions. Sample return from asteroids, comets, Mars, and Jupiter s moons will be an important and natural part of the human exploration of space effort. Here we describe the collector designed for the Hera Near-Earth Asteroid Sample Return Mission. We have built a small prototype for preliminary evaluation, but expect the final collector to gather approx.100 g of sample of dust grains to centimeter sized clasts on each application to the surface of the asteroid.

  11. A study on the levels of a polybrominated biphenyl in Chinese human milk samples collected in 2007 and 2011.

    PubMed

    Liu, Xiao; Wen, Sheng; Li, Jingguang; Zhang, Lei; Zhao, Yunfeng; Wu, Yongning

    2016-09-01

    The levels of a 2,2',4,4',5,5'-hexabromobiphenyl (BB-153) were measured in human milk samples collected in 2007 and 2011 from residents in China by high-resolution gas chromatography-high-resolution mass chromatography (HRGC-HRMS) with isotope dilution. The median concentrations of BB-153 from the samples collected in 2007 and 2011 were 8.3 and 7.2 pg/g lipid weight, respectively. The levels of BB-153 in the human milk collected from rural areas were not significantly different to those collected from the urban areas in China. Meanwhile, significant positive correlations were found between the levels of BB-153 in human milk and the consumption of animal-origin foods. In the present study, the mean levels of BB-153 in human milk from Chinese mothers were found to be lower than those from European and American mothers.

  12. Analytical results for 544 water samples collected in the Attean Quartz Monzonite in the vicinity of Jackman, Maine

    USGS Publications Warehouse

    Ficklin, W.H.; Nowlan, G.A.; Preston, D.J.

    1983-01-01

    Water samples were collected in the vicinity of Jackman, Maine as a part of the study of the relationship of dissolved constituents in water to the sediments subjacent to the water. Each sample was analyzed for specific conductance, alkalinity, acidity, pH, fluoride, chloride, sulfate, phosphate, nitrate, sodium, potassium, calcium, magnesium, and silica. Trace elements determined were copper, zinc, molybdenum, lead, iron, manganese, arsenic, cobalt, nickel, and strontium. The longitude and latitude of each sample location and a sample site map are included in the report as well as a table of the analytical results.

  13. Molecular Epidemiology of HIV-1 in Panama: Origin of Non-B Subtypes in Samples Collected from 2007 to 2013

    PubMed Central

    Mendoza, Yaxelis; Bello, Gonzalo; Castillo Mewa, Juan; Martínez, Alexander A.; González, Claudia; García-Morales, Claudia; Avila-Ríos, Santiago; Reyes-Terán, Gustavo; Pascale, Juan M.

    2014-01-01

    Phylogenetic studies have suggested that the HIV-1 epidemic in the Americas is mainly dominated by HIV subtype B. However, countries of South America and the Caribbean have recently reported changes in their circulating HIV-1 genetic profiles. The aim of this study was to characterize the molecular profile of the HIV-1 epidemic in Panama by the analysis of 655 polymerase gene (pol) sequences that were obtained from HIV-infected Panamanians diagnosed between 1987 and 2013. Blood samples were collected from recently infected, antiretroviral drug-naïve and treatment-experienced subjects since mid-2007 to 2013. Viral RNA from plasma was extracted and sequences of HIV protease and reverse transcriptase genes were obtained. Bootscanning and phylogenetic methods were used for HIV subtyping and to trace the putative origin of non-B subtype strains. Our results showed that HIV-1 infections in Panama are dominated by subtype B (98.9%). The remaining 1.1% is represented by a diverse collection of recombinant variants including: three URFs_BC, one CRF20_BG, and one CRF28/29_BF, in addition to one subtype F1 and one subtype C, none of which were previously reported in Panama. The non-B subtype variants detected in Panama were probably introduced from Brazil (subtype F1 and CRF28/29_BF), Cuba (CRF20_BG), Dominican Republic (URFs_BC) and India (subtype C). Panama is the geographical vertex that connects the North with South America and the Caribbean through trade and cultural relations, which may explain the observed introductions of non-B subtype HIV-1 variants from both the Caribbean and South America into this Central American country. PMID:24454808

  14. Improved method for collection of sputum for tuberculosis testing to ensure adequate sample volumes for molecular diagnostic testing.

    PubMed

    Fisher, Mark; Dolby, Tania; Surtie, Shireen; Omar, Gaironesa; Hapeela, Nchimunya; Basu, Debby; DeWalt, Abby; Kelso, David; Nicol, Mark; McFall, Sally

    2017-04-01

    The quality and quantity of sputum collected has an important impact on the laboratory diagnosis of pulmonary TB. We conducted a pilot study to assess a new collection cups for the collection of sputum for the diagnosis of pulmonary tuberculosis. The pilot study utilized the standard collection cup in South Africa demonstrating a mean collection volume of 2.86±2.36SDml for 198 samples; 19% of the specimens contained <1ml and 12% contained >5ml. We designed and tested two novel sputum cups with a narrow bottom section and clear minimum and maximum markings to allow patients and clinicians to know whether sufficient sputum volume has been produced. The cups differed in their shape and manufacturing approach. The two options also support different mixing approaches being considered for a highly sensitive companion TB-screening assay being developed at Northwestern University (XtracTB assay). Sputum was collected from 102 patients at Nolungile Youth Centre, Khayelitsha, Cape Town, South Africa for a total of 204 samples. The mean volumes collected from the two cups were 2.70±0.88SDml and 2.88±0.89SDml. While the mean volumes of current and novel cups are similar, the volume ranges collected with the novel cups were narrower, and 98% of the specimen volumes were within the target range. Only 4 samples contained >5ml, but none were >6ml, and none of the specimens contained <1ml. The number of coughs that produced the samples, patient HIV and TB status plus qualitative descriptions of the sputum specimens were also evaluated.

  15. Sample Collection Information Document for Chemical & Radiochemical Analytes – Companion to Selected Analytical Methods for Environmental Remediation and Recovery (SAM) 2012

    EPA Pesticide Factsheets

    Sample Collection Information Document is intended to provide sampling information to be used during site assessment, remediation and clearance activities following a chemical or radiological contamination incident.

  16. Sample Collection Information Document for Pathogens and Biotoxins − Companion to Standardized Analytical Methods for Environmental Restoration Following Homeland Security Events (SAM) Revision 5.0

    EPA Pesticide Factsheets

    Sample Collection Information Document is intended to provide sampling information to be used during site assessment, remediation and clearance activities following a biological or biotoxin contamination incident.

  17. Apparatus for Collection of Fecal Samples from Undisturbed Spiny Mice (Acomys cahirinus) Living in a Complex Social Group

    PubMed Central

    Frynta, Daniel; Nováková, Marcela; Kutalová, Hana; Palme, Rupert; Sedláček, František

    2009-01-01

    Assessment of fecal glucocorticoid metabolites has become a widely used method for monitoring stress responses. Because most small rodents are social animals whose physiologic parameters are affected by social stimuli, individual housing may compromise these data. Nevertheless, housing rodents in families or social groups may be an important limitation to the experimental design. The challenge is to collect samples from individual rodents while avoiding stress-associated effects from the sampling method itself. Here we present an apparatus and protocol allowing routine repeated collection of an individual rodent's fresh fecal samples without noticeable disturbance of any of the study animals; continuous maintenance of studied animals in a familiar environment; group housing; and uninterrupted visual and olfactory communication among group members during sampling. The apparatus consists of 1 central and 4 lateral compartments. The experimental animal was allowed to enter a lateral compartment voluntarily, where it remained for the short (4 h) period necessary for sample collection before rejoining the rest of the group. Evaluations involved Egyptian spiny mice, a social rodent increasingly studied in laboratories. The results confirmed the repeatability of the assessment of baseline levels of glucocorticoid metabolites. Moreover, keeping the animals in our experimental apparatus did not induce any increase in the levels of glucocorticoid metabolites, even when isolation in the compartment was relatively prolonged. We interpret these results as confirmation that our sampling procedure allows repeated individual sampling within a nearly undisturbed social unit. PMID:19383218

  18. Apparatus for collection of fecal samples from undisturbed spiny mice (Acomys cahirinus) living in a complex social group.

    PubMed

    Frynta, Daniel; Nováková, Marcela; Kutalová, Hana; Palme, Rupert; Sedlácek, Frantisek

    2009-03-01

    Assessment of fecal glucocorticoid metabolites has become a widely used method for monitoring stress responses. Because most small rodents are social animals whose physiologic parameters are affected by social stimuli, individual housing may compromise these data. Nevertheless, housing rodents in families or social groups may be an important limitation to the experimental design. The challenge is to collect samples from individual rodents while avoiding stress-associated effects from the sampling method itself. Here we present an apparatus and protocol allowing routine repeated collection of an individual rodent's fresh fecal samples without noticeable disturbance of any of the study animals; continuous maintenance of studied animals in a familiar environment; group housing; and uninterrupted visual and olfactory communication among group members during sampling. The apparatus consists of 1 central and 4 lateral compartments. The experimental animal was allowed to enter a lateral compartment voluntarily, where it remained for the short (4 h) period necessary for sample collection before rejoining the rest of the group. Evaluations involved Egyptian spiny mice, a social rodent increasingly studied in laboratories. The results confirmed the repeatability of the assessment of baseline levels of glucocorticoid metabolites. Moreover, keeping the animals in our experimental apparatus did not induce any increase in the levels of glucocorticoid metabolites, even when isolation in the compartment was relatively prolonged. We interpret these results as confirmation that our sampling procedure allows repeated individual sampling within a nearly undisturbed social unit.

  19. Bridging the Gap between Sample Collection and Laboratory Analysis: Using Dried Blood Spots to Identify Human Exposure to Chemical Agents.

    PubMed

    Hamelin, Elizabeth I; Blake, Thomas A; Perez, Jonas W; Crow, Brian S; Shaner, Rebecca L; Coleman, Rebecca M; Johnson, Rudolph C

    2016-05-13

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  20. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    NASA Astrophysics Data System (ADS)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  1. The 'Prof. Dr. Rómulo Lambre' Collection: an Argentinian sample of modern skeletons.

    PubMed

    Salceda, S A; Desántolo, B; Mancuso, R García; Plischuk, M; Inda, A M

    2012-08-01

    This paper describes the 'Prof. Dr. Rómulo Lambre' skeletal collection. The Lambre Collection is housed in the School of Medical Sciences of the National University of La Plata and it consists of skeletal remains ceded by the Municipal Cemetery of La Plata. The collection has more than four hundred skeletons, with information on age, sex, nationality, date and cause of death. It was created for teaching and research purposes in compliance with current legislation, and its management meets guidelines specified in the Declaration of the Argentinian Association for Biological Anthropology on Research Ethics on Human Remains (2007).

  2. Challenges in collecting clinical samples for research from pregnant women of South Asian origin: evidence from a UK study

    PubMed Central

    Neelotpol, Sharmind; Hay, Alastair W M; Jolly, A Jim; Woolridge, Mike W

    2016-01-01

    Objective To recruit South Asian pregnant women, living in the UK, into a clinicoepidemiological study for the collection of lifestyle survey data and antenatal blood and to retain the women for the later collection of cord blood and meconium samples from their babies for biochemical analysis. Design A longitudinal study recruiting pregnant women of South Asian and Caucasian origin living in the UK. Setting Recruitment of the participants, collection of clinical samples and survey data took place at the 2 sites within a single UK Northern Hospital Trust. Participants Pregnant women of South Asian origin (study group, n=98) and of Caucasian origin (comparison group, n=38) living in Leeds, UK. Results Among the participants approached, 81% agreed to take part in the study while a ‘direct approach’ method was followed. The retention rate of the participants was a remarkable 93.4%. The main challenges in recruiting the ethnic minority participants were their cultural and religious conservativeness, language barrier, lack of interest and feeling of extra ‘stress’ in taking part in research. The chief investigator developed an innovative participant retention method, associated with the women's cultural and religious practices. The method proved useful in retaining the participants for about 5 months and in enabling successful collection of clinical samples from the same mother–baby pairs. The collection of clinical samples and lifestyle data exceeded the calculated sample size required to give the study sufficient power. The numbers of samples obtained were: maternal blood (n=171), cord blood (n=38), meconium (n=176), lifestyle questionnaire data (n=136) and postnatal records (n=136). Conclusions Recruitment and retention of participants, according to the calculated sample size, ensured sufficient power and success for a clinicoepidemiological study. Results suggest that development of trust and confidence between the participant and the researcher is the

  3. 7 CFR 52.44 - Inspection fees when charges for sampling have been collected.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... collected. 52.44 Section 52.44 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946 PROCESSED FRUITS AND VEGETABLES, PROCESSED...

  4. Predictors of victim disclosure in child sexual abuse: Additional evidence from a sample of incarcerated adult sex offenders.

    PubMed

    Leclerc, Benoit; Wortley, Richard

    2015-05-01

    The under-reporting of child sexual abuse by victims is a serious problem that may prolong the suffering of victims and leave perpetrators free to continue offending. Yet empirical evidence indicates that victim disclosure rates are low. In this study, we perform regression analysis with a sample of 369 adult child sexual offenders to examine potential predictors of victim disclosure. Specifically, we extend the range of previously examined potential predictors of victim disclosure and investigate interaction effects in order to better capture under which circumstances victim disclosure is more likely. The current study differs from previous studies in that it examines the impact of victim and offense variables on victim disclosure from the perspective of the offender. In line with previous studies, we found that disclosure increased with the age of the victim and if penetration had occurred. In addition, we found that disclosure increased when the victim came from a non-dysfunctional family and resisted the abuse. The presence of an interaction effect highlighted the impact of the situation on victim disclosure. This effect indicated that as victims get older, they are more likely to disclose the abuse when they are not living with the offender at the time of abuse, but less likely to do so when they are living with the offender at the time of abuse. These findings are discussed in relation to previous studies and the need to facilitate victim disclosure.

  5. Analyses of Gas, Steam and Water Samples Collected in and Around Lassen Volcanic National Park, California, 1975-2002

    USGS Publications Warehouse

    Janik, Cathy J.; Bergfeld, D.

    2010-01-01

    This report contains physical and chemical data from gas, steam, and water samples collected between July 1975 and September 2002 from locations in and around Lassen Volcanic National Park, California. Data are compiled as tables in Excel spreadsheets and are organized by locale. Most data are keyed to 1 of 107 site codes that are shown on local- and regional-scale maps. Brief descriptions of terminology, sampling, and analytical methods are provided.

  6. Investigation into Alternative Sample Preparation Techniques for the Determination of Heavy Metals in Stationary Source Emission Samples Collected on Quartz Filters

    PubMed Central

    Goddard, Sharon L.; Brown, Richard J. C.

    2014-01-01

    Monitoring stationary source emissions for heavy metals generally requires the use of quartz filters to collect samples because of the high temperature and high moisture sampling environment. The documentary standard method sample preparation technique in Europe, EN 14385, uses digestion in hydrofluoric acid and nitric acid (HF/HNO3) followed by complexing with boric acid (H3BO3) prior to analysis. However, the use of this method presents a number of problems, including significant instrumental drift during analysis caused by the matrix components, often leading to instrument breakdown and downtime for repairs, as well as posing significant health and safety risks. The aim of this work was to develop an alternative sample preparation technique for emissions samples on quartz filters. The alternative techniques considered were: (i) acid digestion in a fluoroboric acid (HBF4) and HNO3 mixture and (ii) acid extraction in an aqua regia (AR) mixture (HCl and HNO3). Assessment of the effectiveness of these options included determination of interferences and signal drift, as well as validating the different methods by measurement of matrix certified reference materials (CRMs), and comparing the results obtained from real test samples and sample blanks to determine limits of detection. The results showed that the HBF4/HNO3 mixture provides the most viable alternative to the documentary standard preparation technique. PMID:25407906

  7. Detection of environmental DNA of Bigheaded Carps in samples collected from selected locations in the St. Croix River and in the Mississippi River

    USGS Publications Warehouse

    Amberg, Jon J.; McCalla, S. Grace; Miller, Loren; Sorensen, Peter; Gaikowski, Mark P.

    2013-01-01

    Assurance Project Plan with minor deviations designed to enhance the rigor of our data. Presence of DNA in PCR-positive samples was confirmed by Sanger sequencing (forward and reverse) and sequences were considered positive only if sequences (forward and reverse) of ≥150 base pairs had a match of ≥95% to those of published sequences for bighead carp or silver carp. The DNA of bighead carp and silver carp was not detected in environmental samples collected above and below St. Croix Falls Dam on the St. Croix River, above and below the Coon Rapids Dam and below Lock and Dam 1 on the Upper Mississippi River, and from two negative control lakes, Square Lake and Lake Riley. The DNA of silver carp was detected in environmental samples collected below Lock and Dam 19 at Keokuk, Iowa, a reach of the river with high silver carp abundance. The portion (68%) of environmental samples taken below Lock and Dam 19 that were determined to contain the DNA of silver carp was similar to that reported in the scientific literature for other abundant species. The DNA of bighead carp, however, was not detected in environmental samples collected below Lock and Dam 19, a reach of the river known to have bighead carp. Previous reported detections of the DNA of silver carp in samples collected in 2011 were not replicated in this study. Additional analyses are planned for the DNA extracted from the samples collected in 2012. Those analyses may provide additional information regarding the lack of amplification of bighead carp DNA and the lengths of the sequences of silver carp DNA present in samples taken below Lock and Dam 19. These additional analyses may help inform the use of eDNA monitoring in large, complex systems like the Mississippi River.

  8. Analysis of Biodiesel Blends Samples Collected in the United States in 2008 (Revised)

    SciTech Connect

    Alleman, T. L.; Fouts, L.; McCormick, R. L.

    2010-12-01

    NREL sampled and tested the quality of U.S. B20 (20% biodiesel, 80% petroleum diesel) in 2008; 32 samples from retail locations and fleets were tested against a proposed ASTM D7467 B6-B20 specification, now in effect.

  9. A Future Moon Mission: Curatorial Statistics on Regolith Fragments Applicable to Sample Collection by Raking

    NASA Technical Reports Server (NTRS)

    Allton, J. H.; Bevill, T. J.

    2003-01-01

    The strategy of raking rock fragments from the lunar regolith as a means of acquiring representative samples has wide support due to science return, spacecraft simplicity (reliability) and economy [3, 4, 5]. While there exists widespread agreement that raking or sieving the bulk regolith is good strategy, there is lively discussion about the minimum sample size. Advocates of consor-tium studies desire fragments large enough to support petrologic and isotopic studies. Fragments from 5 to 10 mm are thought adequate [4, 5]. Yet, Jolliff et al. [6] demonstrated use of 2-4 mm fragments as repre-sentative of larger rocks. Here we make use of cura-torial records and sample catalogs to give a different perspective on minimum sample size for a robotic sample collector.

  10. 21 CFR 809.40 - Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs of abuse testing. 809.40 Section 809.40 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES...

  11. 21 CFR 809.40 - Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs of abuse testing. 809.40 Section 809.40 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES...

  12. 21 CFR 809.40 - Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs of abuse testing. 809.40 Section 809.40 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES...

  13. 21 CFR 809.40 - Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs of abuse testing. 809.40 Section 809.40 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES...

  14. 21 CFR 809.40 - Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs of abuse testing. 809.40 Section 809.40 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES...

  15. Detection of Group B Streptococcus Directly from Collected ESwab Samples by Use of the BD Max GBS Assay

    PubMed Central

    Rocchetti, Talita T.; Gostnell, Alicia; Kubasek, Carly; Widen, Raymond

    2016-01-01

    Group B Streptococcus detection directly from Copan ESwab collected samples, using the BD Max GBS assay, was evaluated on receipt in the laboratory and after 24 h at room temperature. Results were compared to those using Lim broth enrichment PCR and culture. No significant difference was observed between 24 h ESwab and Lim broth PCRs. PMID:27053670

  16. RECOMMENDED OPERATING PROCEDURE NO. 56: COLLECTION OF GASEOUS GRAB SAMPLES FROM COMBUSTION SOURCES FOR NITROUS OXIDE MEASUREMENT

    EPA Science Inventory

    The document is a recommended operating procedure, prepare or use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). The procedure applies to the collection of gaseous grab samples from fossil fuel combustion sources for subsequent a...

  17. EVALUATING COMMERCIALLY AVAILABLE DERMAL WIPES, COTTON SUITES, AND ALTERNATIVE URINARY COLLECTION MATERIALS FOR PESTICIDE SAMPLING FROM INFANTS

    EPA Science Inventory

    As the Human Exposure Program focuses on the exposure of children to pesticides, there are concerns about the effect, or perceived effect, of components of the sampling procedure on the health and well-being of the infant and the ability to collect pesticide residues.

    One...

  18. Illuminating the NARS data entry black box: what happens between sample collection and data availability for use in assessments?

    EPA Science Inventory

    The steps between field collection of data and samples and availability of the resulting data from National Aquatic Resource Surveys (NARS) can appear to be a black box. This presentation is intended to shed some light on that process. The pathway for data depends on their source...

  19. Analyses of native water, core material, and elutriate samples collected from the Atchafalaya River and Atchafalaya Bay

    USGS Publications Warehouse

    Demas, Charles R.

    1977-01-01

    During October and November 1976 the U.S. Geological Survey, in cooperation with the U.S. Army Corps of Engineers, collected native water and core material from 14 sites along the Atchafalya River in Louisiana (from the head of Whiskey Bay Pilot Channel to American Pass) and 5 sites in Atchafalya Bay for evaluation of possible environmental effects of a proposed channel-enlargement project. Core material from all river sites and one bay site was collected to a depth of 50 feet (15 meters). At the remaining bay sites, samples were collected to a depth of less than 6 inches (15 centimeters) using a pipe dredge. Core material and native water were analyzed (separately and as elutriate samples prepared from mixtures) for selected metals, nutrients, organic compounds, and physical characteristics. No interpretation of the data is given. (Woodard-USGS)

  20. Performance of Self-Collected Cervical Samples in Screening for Future Precancer Using Human Papillomavirus DNA Testing

    PubMed Central

    Hildesheim, Allan; González, Paula; Schiffman, Mark; Rodríguez, Ana Cecilia; Wacholder, Sholom; Jiménez, Silvia; Quint, Wim; Guillen, Diego; Kreimer, Aimée R.; Herrero, Rolando

    2015-01-01

    Background: Self-collected human papillomavirus (HPV) testing could reduce barriers to cervical cancer screening, with performance comparable to clinician-collected specimens. The ability of self-collected specimens to cross-sectionally and prospectively detect precursor lesions was investigated in an HPV vaccine randomized trial in Costa Rica. Methods: In the trial, 7466 women age 18 to 25 years received an HPV16/18 or control vaccine and were followed at least annually for four years. In this secondary analysis, we included all women who provided a self-collected cervicovaginal specimen six months after enrollment (5109 women = full analytical cohort). A subset (615 women = restricted cohort) also had clinician-collected specimens at the six-month postenrollment visit. High-grade squamous intraepithelial lesion or repeat low-grade squamous intraepithelial lesion prompted colposcopic referral throughout the study. HPV testing was performed with SPF10PCR/DEIA/LiPA25. Cross-sectional and prospective sensitivity, specificity, and predictive values were estimated. Results: In the full cohort, one-time HPV testing on self-collected samples detected prevalent CIN2+ with a sensitivity of 88.7% (95% confidence interval [CI] =77.0% to 95.7%) and a specificity of 68.9% (95% CI = 67.6% to 70.1%). For predicting incident CIN2+ in the subsequent four years, sensitivity was 73.9% (95% CI = 65.8% to 81.0%) and specificity 69.4% (95% CI = 68.1% to 70.7%). In the restricted cohort, for incident CIN2+, self-collected HPV was much more sensitive than cytology (80.0% vs 10.0%); relative sensitivity was 0.1 (95% CI = 0.03% to 0.5%). Furthermore, three times more women with normal baseline cytology developed incident CIN2+ than those with negative self-collected HPV. Self-collected and clinician-collected HPV testing had comparable performance. Agreement between self- and clinician-collected samples was 89.7% (kappa = 0.78, McNemar χ2 = 0.62) for carcinogenic HPV types. Conclusions

  1. Effects of sampling nozzles on the particle-collection characteristics of inertial sizing devices. Final report

    SciTech Connect

    Williamson, A.D.; Farthing, W.E.; Ward, T.E.; Midgett, M.R.

    1987-05-01

    In several particle-sizing samplers, the sample extraction nozzle is necessarily closely coupled to the first inertial sizing stage. Devices of this type include small sampling cyclones, right-angle impactor precollectors for in-stack impactors, and the first impaction stage of several cascade impactors. In a recent laboratory study of a stack-sampling cyclone with various sampling nozzles, significant perturbations were observed in the actual D50 when some of the nozzles were used. Some nozzles caused the D50 of the cyclone to be reduced from 10 micrometers to less than 6 micrometers. Several alternate nozzle designs were considered to alleviate this behavior. Simple extension of the nozzle length was sufficient to restore the 10-micrometers sampler D50, but at the expense of enhanced deposition of the test-aerosol particles on the nozzle walls.

  2. The brominated flame retardants, PBDEs and HBCD, in Canadian human milk samples collected from 1992 to 2005; concentrations and trends.

    PubMed

    Ryan, John Jake; Rawn, Dorothea F K

    2014-09-01

    Human milk samples were collected from individuals residing in various regions across Canada mostly in the years 1992 to 2005. These included five large cities in southern Canada as well as samples from Nunavik in northern Quebec. Comparative samples were also collected from residents of Austin, Texas, USA in 2002 and 2004. More than 300 milk samples were analysed for the brominated flame retardants (BFRs), PBDEs and HBCD, by extraction, purification and quantification using either isotope dilution gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-MS. The Canadian total PBDE values in the years 2002-2005 show median levels of about 20μg/kg on a lipid basis; a value significantly higher than in the 1980s and 1990s. Milk samples from Inuit donors in the northern region of Nunavik were slightly lower in PBDE concentrations than those from populated regions in the south of Quebec. Milk samples from Ontario contained slightly lower amounts of PBDEs in two time periods than those from Texas. HBCD levels in most milk samples were usually less than 1ppb milk lipid and dominated by the α-isomer. This large data set of BFRs in Canadian human milk demonstrates an increase in the last few decades in human exposure to BFRs which now appears to have stabilized.

  3. Evaluation of a novel tagging and tissue preservation system for potential use in forensic sample collection.

    PubMed

    Grassberger, Martin; Stein, Christina; Hanslik, Stefan; Hochmeister, Manfred

    2005-07-16

    The authors describe a new, easy-to-use barcode-based tissue collection, preservation and body tracking system, which might prove instrumental in the containment of mass fatalities such as aircraft accidents, war related accidents, environmental disasters (e.g. earthquakes, hurricanes, and floods) terrorist bombings or mass murders.

  4. CTEPP DATA COLLECTION FORM 01: RECRUITMENT SURVEY FOR DAY CARE CENTER SAMPLE SUBJECTS

    EPA Science Inventory

    This data collection form is used to identify eligible preschool children who attend day care during the day and recruit them into the study.

    The Children's Total Exposure to Persistent Pesticides and Other Persistent Pollutant (CTEPP) study was one of the largest aggregate ex...

  5. CTEPP DATA COLLECTION FORM 01_RDD: RECRUITMENT SURVEY FOR HOME SAMPLE SUBJECTS

    EPA Science Inventory

    This data collection form is used to identify eligible preschool children who stay home during the day with their primary adult care giver and recruit them into the study.

    The Children's Total Exposure to Persistent Pesticides and Other Persistent Pollutant (CTEPP) study was o...

  6. Operational Procedures for Collecting Water-Quality Samples at Monitoring Sites on Maple Creek Near Nickerson and the Platte River at Louisville, Eastern Nebraska

    USGS Publications Warehouse

    Johnson, Steven M.; Swanson, Robert B.

    1994-01-01

    Prototype stream-monitoring sites were operated during part of 1992 in the Central Nebraska Basins (CNBR) and three other study areas of the National Water-Quality Assessment (NAWQ) Program of the U.S. Geological Survey. Results from the prototype project provide information needed to operate a net- work of intensive fixed station stream-monitoring sites. This report evaluates operating procedures for two NAWQA prototype sites at Maple Creek near Nickerson and the Platte River at Louisville, eastern Nebraska. Each site was sampled intensively in the spring and late summer 1992, with less intensive sampling in midsummer. In addition, multiple samples were collected during two high- flow periods at the Maple Creek site--one early and the other late in the growing season. Water-samples analyses included determination of pesticides, nutrients, major ions, suspended sediment, and measurements of physical properties. Equipment and protocols for the water-quality sampling procedures were evaluated. Operation of the prototype stream- monitoring sites included development and comparison of onsite and laboratory sample-processing proce- dures. Onsite processing was labor intensive but allowed for immediate preservation of all sampled constituents. Laboratory processing required less field labor and decreased the risk of contamination, but allowed for no immediate preservation of the samples.

  7. The evidence of `CHOl' in sediment core samples of pacific ocean collected among FGGE

    NASA Astrophysics Data System (ADS)

    Han-chang, Peng; Kui-huan, Zhao; Sui-tian, Chen

    1982-07-01

    Three new microtektite sites have been identified in addition to the known world distributions. This is of significance for confirming and extending the known range of tektite distributions and for a thorough study of their origin.

  8. Vapor space characterization of waste tank 241-BY-107: Results from samples collected on 10/26/94

    SciTech Connect

    Clauss, T.W.; Ligotke, M.W.; Pool, K.H.

    1995-10-01

    This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-BY-107 (referred to as Tank BY-107). Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The organic analytes for TO-14 compounds were extended to include 15 analytes identified by the Toxicological Review Panel for Tank C-103 and reported in Toxicological Evaluation of Analytes from Tank 241-C-103 PAE-10189. While these analytes are only of toxicological concern for Tank C-103, program management included these analytes for future tank analyses as identified in the fiscal year work plan. This plan is attached to a letter dated 9/30/94 and addressed to Mr. T. J. Kelly of WHC. The plan also requires PNL to analyze for the permanent gases as shown in Table 3.5. The sample job was designated S4077, and samples were collected by WHC on October 26, 1994, using the vapor sampling system (VSS). Sampling devices, including six sorbent trains (for inorganic analyses), and six SUMMA{trademark} canisters (for organic analyses) were supplied to the WHC sampling staff on October 24. Samples were taken (by WHC) from the tank headspace on October 26 and were returned to PNL from the field on November 8. Inorganic (sorbent trap) samples were delivered to PNL on chain of custody (COC) 008071. The SUMMA{trademark} canisters were delivered on COC 008070. Three SUMMA{trademark} canister samples were stored at the PNL 326/23B laboratory pending further instruction from WHC to send them to the Oregon Graduate Institute (OGI) for analysis.

  9. Effect of blood sample handling post-collection on Erysipelothrix rhusiopathiae antibody titres.

    PubMed

    Neumann, Eric J; Bonistalli, Kathryn N

    2009-06-01

    A study was conducted to determine the effect of blood sample mishandling on the performance of an enzyme-linked immunosorbent assay for the detection of antibodies against Erysipelothrix rhusiopathiae. Eleven sample maltreatments (storage at -10 degrees C, storage at 4 degrees C, heat treatment of clotted blood, haemolysis, repetitive freeze-thaw cycling, and substitution of plasma in place of serum) were simulated in a laboratory environment and then run concurrently against a gold standard sample (storage at -80 degrees C). The mishandling treatment groups that simulated high levels of haemolysis had significantly lower optical density (OD) readings when compared to the gold standard. However, the magnitude of the effects was relatively small and only samples with OD values close to the cut-off changed state from positive to negative. Heat treatment had a minor, but non-significant, effect on OD values. Findings from this study suggested that immunoglobulin G antibody was stable in the face of most common sample mishandling events.

  10. Methods for collection and analysis of aquatic biological and microbiological samples

    SciTech Connect

    Britton, L.J.; Greeson P.E.

    1989-01-01

    Chapter A4 contains methods used by the US Geological Survey to collect, preserve, and analyze waters to determine their biological and microbiological properties. Part 1 consists of detailed descriptions of more than 45 individual methods, including those for bacteria, phytoplankton, zooplankton, seston, periphyton, macrophytes, benthic invertebrates, fish and other vertebrates, cellular contents, productivity, and bioassays; Part 2 consists of a glossary; and Part 3 is a list of taxonomic references.

  11. Hematologic Assessment in Pet Rats, Mice, Hamsters, and Gerbils: Blood Sample Collection and Blood Cell Identification.

    PubMed

    Lindstrom, Nicole M; Moore, David M; Zimmerman, Kurt; Smith, Stephen A

    2015-09-01

    Hamsters, gerbils, rats, and mice are presented to veterinary clinics and hospitals for prophylactic care and treatment of clinical signs of disease. Physical examination, history, and husbandry practice information can be supplemented greatly by assessment of hematologic parameters. As a resource for veterinarians and their technicians, this article describes the methods for collection of blood, identification of blood cells, and interpretation of the hemogram in mice, rats, gerbils, and hamsters.

  12. Hematologic assessment in pet rats, mice, hamsters, and gerbils: blood sample collection and blood cell identification.

    PubMed

    Lindstrom, Nicole M; Moore, David M; Zimmerman, Kurt; Smith, Stephen A

    2015-01-01

    Hamsters, gerbils, rats, and mice are presented to veterinary clinics and hospitals for prophylactic care and treatment of clinical signs of disease. Physical examination, history, and husbandry practice information can be supplemented greatly by assessment of hematologic parameters. As a resource for veterinarians and their technicians, this article describes the methods for collection of blood, identification of blood cells, and interpretation of the hemogram in mice, rats, gerbils, and hamsters.

  13. Collection Methods and Laboratory Processing of Samples from Donnelly Training Area Firing Points, Alaska, 2003

    DTIC Science & Technology

    2005-03-01

    centration and variance in 10-g subsamples from 500-g samples of Ottawa sand spiked with either a fiber of M1 propellant or grains of SARM 2,4-DNT...Material ( SARM ) 2,4-DNT. Each spiked sample was ground on the ring mill for 60 s and twelve 10-g subsamples taken for analysis. Then the remainder of the...totaling less than 1 mg) of 2,4-DNT (Standard Analytical Refer- ence Material [ SARM ]) to another 500 g of Ottawa sand and processed the sand in the

  14. Collection Methods and Laboratory Processing of Samples From Donnelly Training Area Firing Points, Alaska, 2003

    DTIC Science & Technology

    2005-03-01

    centration and variance in 10-g subsamples from 500-g samples of Ottawa sand spiked with either a fiber of M1 propellant or grains of SARM 2,4-DNT...Material ( SARM ) 2,4-DNT. Each spiked sample was ground on the ring mill for 60 s and twelve 10-g subsamples taken for analysis. Then the remainder of the...totaling less than 1 mg) of 2,4-DNT (Standard Analytical Refer- ence Material [ SARM ]) to another 500 g of Ottawa sand and processed the sand in the

  15. Curating NASA's Future Extraterrestrial Sample Collections: How Do We Achieve Maximum Proficiency?

    NASA Technical Reports Server (NTRS)

    McCubbin, Francis; Evans, Cynthia; Zeigler, Ryan; Allton, Judith; Fries, Marc; Righter, Kevin; Zolensky, Michael

    2016-01-01

    The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10E "Curation of Extraterrestrial Materials", JSC is charged with "The curation of all extraterrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "... documentation, preservation, preparation, and distribution of samples for research, education, and public outreach." Here we describe some of the ongoing efforts to ensure that the future activities of the NASA Curation Office are working towards a state of maximum proficiency.

  16. Environmental radioactivity of water samples collected in Higashi-Hiroshima campus, Hiroshima University, Japan.

    PubMed

    Nakashima, S; Sasai, A; Koga, K; Yasuhara, H; Matsushima, A; Inada, K

    2015-11-01

    The relation between concentration of elements and microbial activity in the water samples of Higashi-Hiroshima Campus, Hiroshima University was investigated. Energy dispersive X-ray spectroscopy revealed that microbial mat contains iron, aluminium, silicon and phosphorus. Model experiment revealed that the potassium was adsorbed by living microorganism in the microbial mats, while it was not adsorbed by dead microbial mat. Iron was adsorbed by both living and dead microbial mats. The present results explain the increase in the total β-radioactivity of water sample in summer and the decrease in winter.

  17. Recovery of a fish pathogenic bacterium, Aeromonas salmonicida, from ebonyshell mussels Fusconaia ebena using nondestructive sample collection procedures

    USGS Publications Warehouse

    Starliper, C.E.

    2008-01-01

    Refugia are increasingly being used to maintain and propagate imperiled freshwater mussels for future population augmentations. Success for this endeavor is dependent on good husbandry, including a holistic program of resource health management. A significant aspect to optimal health is the prevention or control of infectious diseases. Describing and monitoring pathogens and diseases in mussels involves examination of tissues or samples collected from an appropriate number of individuals that satisfies a certain confidence level for expected prevalences of infections. In the present study, ebonyshell mussels Fusconaia ebena were infected with a fish pathogenic bacterium, Aeromonas salmonicida, through their cohabitation with diseased brook trout Salvelinus fontinalis. At a 100% prevalence of infection, the F. ebena were removed from the cohabitation tank to clean tanks that were supplied with pathogen-free water, which initiated their depuration of A. salmonicida. Three samples (nondestructive fluid, mantle, hemolymph) collected using nondestructive procedures were compared with fluids and soft tissue homogenates collected after sacrificing the mussels for recovery of the bacterium during this period of depuration. Nondestructive sample collections, especially ND fluid, provide a comparable alternative to sacrificing mussels to determine pathogen status.

  18. Potential and Challenges in Collecting Social and Behavioral Data on Adolescent Alcohol Norms: Comparing Respondent-Driven Sampling and Web-Based Respondent-Driven Sampling

    PubMed Central

    Hildebrand, Janina; Burns, Sharyn; Zhao, Yun; Lobo, Roanna; Howat, Peter; Allsop, Steve

    2015-01-01

    Background Respondent-driven sampling (RDS) is a method successfully used to research hard-to-access populations. Few studies have explored the use of the Internet and social media with RDS, known as Web-based RDS (WebRDS). This study explored the use of combining both “traditional” RDS and WebRDS to examine the influences on adolescent alcohol use. Objective This paper reports on the recruitment processes and the challenges and enablers of both RDS and WebRDS. It details comparative recruitment data and provides a summary of the utility of both methods for recruiting adolescents to participate in an online survey investigating youth alcohol norms. Methods Process evaluation data collected from research staff throughout the study were used to assess the challenges and solutions of RDS and WebRDS. Pearson chi-square test (Fisher’s exact test if applicable) was used to compare the differences in sociodemographics and drinking behavior between data collected by RDS and WebRDS. Results Of the total sample (N=1012), 232 adolescents were recruited by RDS and 780 by WebRDS. A significantly larger proportion of Aboriginal or Torres Strait Islander (P<.001) participants who spoke English as their main language at home (P=.03), and of middle and lower socioeconomic status (P<.001) was found in the RDS sample. The RDS sample was also found to have a higher occurrence of past 7-day drinking (P<.001) and past 7-day risky drinking (P=.004). No significant differences in gender, age, past month alcohol use, and lifetime alcohol use were observed between the RDS and WebRDS samples. This study revealed RDS and WebRDS used similar lengths of chains for recruiting participants; however, WebRDS conducted a faster rate of recruitment at a lower average cost per participant compared to RDS. Conclusions Using WebRDS resulted in significant improvements in the recruitment rate and was a more effective and efficient use of resources than the traditional RDS method. However, Web

  19. Forage nutritive value of plant samples collected by clipping or rumen evacuation

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Knowing nutritive value and intake of forage by an animal is important to understand methane production data from individual animals in a grazed environment. Digestibility of forages is typically evaluated as the in vitro dry matter disappearance (IVDMD) using a clipped forage sample; however, beef...

  20. COLLECTION OF AMBIENT PARTICULATE MATTER BY POROUS VEGETATION BARRIERS: SAMPLING AND CHARACTERIZATION METHODS

    EPA Science Inventory

    This manuscript describes work done by A. Reff as part of a collaboration begun 3 years ago at Rutgers University with A. Tiwary who was then at the University of Nottingham. The work describes sampling and characterization methods for investigating the effects of vegetative bar...

  1. 76 FR 24862 - Proposed Information Collection; Comment Request; Protocol for Access to Tissue Specimen Samples...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-03

    ... unusual mortality events through two projects, the Marine Mammal Health and Stranding Response Program... for Access to Tissue Specimen Samples From the National Marine Mammal Tissue Bank AGENCY: National... Patricia.Lawson@noaa.gov . SUPPLEMENTARY INFORMATION: I. Abstract In 1989, the National Marine...

  2. SOURCES OF VARIABILITY IN COLLECTION AND PREPARATION OF PAINT AND LEAD-COATING SAMPLES

    EPA Science Inventory

    Chronic exposure of children to lead can result in permanent physiologic impairment. Since surfaces coated with lead-containing paints and varnishes are potential sources of exposure, it is extremely important that reliable methods for sampling and analysis be available. The so...

  3. 21 CFR 111.80 - What representative samples must you collect?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... unique lot within each unique shipment); (b) Representative samples of in-process materials for each... manufacturing record where control is necessary to ensure the identity, purity, strength, and composition of dietary supplements to determine whether the in-process materials meet specifications established...

  4. Sampling Participants’ Experience in Laboratory Experiments: Complementary Challenges for More Complete Data Collection

    PubMed Central

    McAuliffe, Alan; McGann, Marek

    2016-01-01

    Speelman and McGann’s (2013) examination of the uncritical way in which the mean is often used in psychological research raises questions both about the average’s reliability and its validity. In the present paper, we argue that interrogating the validity of the mean involves, amongst other things, a better understanding of the person’s experiences, the meaning of their actions, at the time that the behavior of interest is carried out. Recently emerging approaches within Psychology and Cognitive Science have argued strongly that experience should play a more central role in our examination of behavioral data, but the relationship between experience and behavior remains very poorly understood. We outline some of the history of the science on this fraught relationship, as well as arguing that contemporary methods for studying experience fall into one of two categories. “Wide” approaches tend to incorporate naturalistic behavior settings, but sacrifice accuracy and reliability in behavioral measurement. “Narrow” approaches maintain controlled measurement of behavior, but involve too specific a sampling of experience, which obscures crucial temporal characteristics. We therefore argue for a novel, mid-range sampling technique, that extends Hurlburt’s descriptive experience sampling, and adapts it for the controlled setting of the laboratory. This controlled descriptive experience sampling may be an appropriate tool to help calibrate both the mean and the meaning of an experimental situation with one another. PMID:27242588

  5. Sampling Participants' Experience in Laboratory Experiments: Complementary Challenges for More Complete Data Collection.

    PubMed

    McAuliffe, Alan; McGann, Marek

    2016-01-01

    Speelman and McGann's (2013) examination of the uncritical way in which the mean is often used in psychological research raises questions both about the average's reliability and its validity. In the present paper, we argue that interrogating the validity of the mean involves, amongst other things, a better understanding of the person's experiences, the meaning of their actions, at the time that the behavior of interest is carried out. Recently emerging approaches within Psychology and Cognitive Science have argued strongly that experience should play a more central role in our examination of behavioral data, but the relationship between experience and behavior remains very poorly understood. We outline some of the history of the science on this fraught relationship, as well as arguing that contemporary methods for studying experience fall into one of two categories. "Wide" approaches tend to incorporate naturalistic behavior settings, but sacrifice accuracy and reliability in behavioral measurement. "Narrow" approaches maintain controlled measurement of behavior, but involve too specific a sampling of experience, which obscures crucial temporal characteristics. We therefore argue for a novel, mid-range sampling technique, that extends Hurlburt's descriptive experience sampling, and adapts it for the controlled setting of the laboratory. This controlled descriptive experience sampling may be an appropriate tool to help calibrate both the mean and the meaning of an experimental situation with one another.

  6. A Study on the Perceived Risk of Surface Sample Collection Systems in Proposal Formulation

    NASA Technical Reports Server (NTRS)

    Sunday, Cecily M.

    2012-01-01

    This project compares design and proposal elements from multiple proposals and presents conclusions and recommendations for sampling systems. Contributions from this project include a list of common evaluation themes, concept and proposal-related strengths and weaknesses and ways in which self-identified risks relate the evaluation of the mission.

  7. Field geologic observation and sample collection strategies for planetary surface exploration: Insights from the 2010 Desert RATS geologist crewmembers

    NASA Astrophysics Data System (ADS)

    Hurtado, José M.; Young, Kelsey; Bleacher, Jacob E.; Garry, W. Brent; Rice, James W.

    2013-10-01

    Observation is the primary role of all field geologists, and geologic observations put into an evolving conceptual context will be the most important data stream that will be relayed to Earth during a planetary exploration mission. Sample collection is also an important planetary field activity, and its success is closely tied to the quality of contextual observations. To test protocols for doing effective planetary geologic fieldwork, the Desert RATS (Research and Technology Studies) project deployed two prototype rovers for two weeks of simulated exploratory traverses in the San Francisco volcanic field of northern Arizona. The authors of this paper represent the geologist crewmembers who participated in the 2010 field test. We document the procedures adopted for Desert RATS 2010 and report on our experiences regarding these protocols. Careful consideration must be made of various issues that impact the interplay between field geologic observations and sample collection, including time management; strategies related to duplication of samples and observations; logistical constraints on the volume and mass of samples and the volume/transfer of data collected; and paradigms for evaluation of mission success. We find that the 2010 field protocols brought to light important aspects of each of these issues, and we recommend best practices and modifications to training and operational protocols to address them. Underlying our recommendations is the recognition that the capacity of the crew to "flexibly execute" their activities is paramount. Careful design of mission parameters, especially field geologic protocols, is critical for enabling the crews to successfully meet their science objectives.

  8. Phorbol ester and A23187 have additive but mechanistically separate effects on vasopressin action in rabbit collecting tubule.

    PubMed Central

    Ando, Y; Jacobson, H R; Breyer, M D

    1988-01-01

    Activation of protein kinase C (PKC) and elevation of intracellular calcium ion concentration ([Ca++]i) result from phosphatidylinositol biphosphate (PIP2) breakdown. We previously demonstrated that PKC activation inhibits arginine vasopressin (AVP)-induced osmotic water flow in rabbit cortical collecting tubule (CCT) perfused in vitro at 37 degrees C. To estimate the potential significance of PIP2 turnover as a modulator of water transport in this nephron segment, we examined the effect of Ca on AVP action and explored the mechanisms of action of PKC and increased [Ca++]i. In rabbit CCTs perfused at 37 degrees C, pretreatment with bath A23187 (2 x 10(-8) M, 2 x 10(-6) M), a Ca ionophore, almost totally suppressed AVP (10 microU/ml)-induced peak hydraulic conductivity (Lp). The suppression by 2 x 10(-8) M A23187 was as potent as that by 2 x 10(-6) M A23187, and significant even when it was administered 10 min after AVP. When phorbol myristate acetate (PMA, 10(-9) M), a PKC activator, and A23187 (2 x 10(-8) M) were placed in the bath simultaneously, the combined suppressive effect on peak Lp was greater than that of either inhibitor alone. However, the mechanisms of inhibition by PMA and A23187 were different. While both 10(-7) and 10(-9) M PMA suppression are primarily post-cAMP, A23187 predominantly suppressed a pre-cAMP step: 10(-4) M chlorophenylthio-cAMP-induced peak Lp was not affected by 2 x 10(-8) M A23187, and only partially inhibited by 2 x 10(-6) M A23187. The PMA (10(-7) M) suppression of AVP-induced peak Lp was totally reversed by bath staurosporine (10(-7) M), a PKC inhibitor, but not attenuated by either bath indomethacin (5 x 10(-6) M) or low Ca (1-2 x 10(-6) M) bath medium. In contrast, the A23187 (2 x 10(-8) M) suppression of the peak Lp was not affected by staurosporine, but was significantly reversed by indomethacin or low Ca bath medium. We conclude: (a) Elevation of [Ca++]i, as well as activation of PKC, suppresses the hydroosmotic effect of

  9. An Interdisciplinary Method for the Visualization of Novel High-Resolution Precision Photography and Micro-XCT Data Sets of NASA's Apollo Lunar Samples and Antarctic Meteorite Samples to Create Combined Research-Grade 3D Virtual Samples for the Benefit of Astromaterials Collections Conservation, Curation, Scientific Research and Education

    NASA Technical Reports Server (NTRS)

    Blumenfeld, E. H.; Evans, C. A.; Oshel, E. R.; Liddle, D. A.; Beaulieu, K.; Zeigler, R. A.; Hanna, R. D.; Ketcham, R. A.

    2016-01-01

    New technologies make possible the advancement of documentation and visualization practices that can enhance conservation and curation protocols for NASA's Astromaterials Collections. With increasing demands for accessibility to updated comprehensive data, and with new sample return missions on the horizon, it is of primary importance to develop new standards for contemporary documentation and visualization methodologies. Our interdisciplinary team has expertise in the fields of heritage conservation practices, professional photography, photogrammetry, imaging science, application engineering, data curation, geoscience, and astromaterials curation. Our objective is to create virtual 3D reconstructions of Apollo Lunar and Antarctic Meteorite samples that are a fusion of two state-of-the-art data sets: the interior view of the sample by collecting Micro-XCT data and the exterior view of the sample by collecting high-resolution precision photography data. These new data provide researchers an information-rich visualization of both compositional and textural information prior to any physical sub-sampling. Since January 2013 we have developed a process that resulted in the successful creation of the first image-based 3D reconstruction of an Apollo Lunar Sample correlated to a 3D reconstruction of the same sample's Micro- XCT data, illustrating that this technique is both operationally possible and functionally beneficial. In May of 2016 we began a 3-year research period during which we aim to produce Virtual Astromaterials Samples for 60 high-priority Apollo Lunar and Antarctic Meteorite samples and serve them on NASA's Astromaterials Acquisition and Curation website. Our research demonstrates that research-grade Virtual Astromaterials Samples are beneficial in preserving for posterity a precise 3D reconstruction of the sample prior to sub-sampling, which greatly improves documentation practices, provides unique and novel visualization of the sample's interior and

  10. Elemental Compositions of Comet 81P/Wild 2 Samples Collected by Stardust

    NASA Technical Reports Server (NTRS)

    Flynn, G. J.; Bleuet, P.; Borg, J.; Bradley, J.; Brenker, F.; Brennan, S.; Bridges, J.; Brownlee, D. E.; Bullock, E.; Clark, B. C.; Papanastassiou, D. A.; Schwandt, C. S.; See, T. H.; Taylor, S.; Tsou, P.

    2006-01-01

    We measured the chemical compositions of material from 23 particles in aerogel and residue in 7 craters in aluminum foil, collected during passage of the Stardust spacecraft through the coma of Comet 81P/Wild 2. These particles are chemically heterogeneous at the largest size-scale analyzed, 180 nanograms. The mean chemical composition of this Wild 2 material agrees with the CI meteorite composition for the refractory elements Mg, Si, Cr, Fe, and Ni to 35%, and for Ca and Mn to 50%. The data suggest the moderately volatile elements Cu, Zn, and Ga may be enriched in this Wild 2 material.

  11. The post-occipital spinal venous sinus of the Nile crocodile Crocodylus niloticus: its anatomy and use for blood sample collection and intravenous infusions.

    PubMed

    Myburgh, Jan G; Kirberger, Robert M; Steyl, Johan C A; Soley, John T; Booyse, Dirk G; Huchzermeyer, Fritz W; Lowers, Russel H; Guillette, Louis J

    2014-05-05

    The post-occipital sinus of the spinal vein is often used for the collection of blood samples from crocodilians. Although this sampling method has been reported for several crocodilian species, the technique and associated anatomy has not been described in detail in any crocodilian, including the Nile crocodile (Crocodylus niloticus). The anatomy of the cranial neck region was investigated macroscopically, microscopically, radiographically and by means of computed tomography. Latex was injected into the spinal vein and spinal venous sinus of crocodiles to visualise the regional vasculature. The spinal vein ran within the vertebral canal, dorsal to and closely associated with the spinal cord and changed into a venous sinus cranially in the post-occipital region. For blood collection, the spinal venous sinus was accessed through the interarcuate space between the atlas and axis (C1 and C2) by inserting a needle angled just off the perpendicular in the midline through the craniodorsal cervical skin, just cranial to the cranial borders of the first cervical osteoderms. The most convenient method of blood collection was with a syringe and hypodermic needle. In addition, the suitability of the spinal venous sinus for intravenous injections and infusions in live crocodiles was evaluated. The internal diameter of the commercial human epidural catheters used during these investigations was relatively small, resulting in very slow infusion rates. Care should be taken not to puncture the spinal cord or to lacerate the blood vessel wall using this route for blood collection or intravenous infusions.

  12. [Detection of Avian Influenza Virus in Environmental Samples Collected from Live Poultry Markets in China during 2009-2013].

    PubMed

    Zhang, Ye; Li, Xiaodan; Zou, Shumei; Bo, Hong; Dong, Libo; Gao, Rongbao; Wang, Dayan; Shu, Yuelong

    2015-11-01

    Abstract: To investigate the distribution of avian influenza virus in environmental samples from live poultry markets (LPM) in China, samples were collected and tested by nucleic acid during 2009-2013 season. Each sample was tested by real-time RT PCR using flu A specific primers. If any real-time PCR was positive, the sample was inoculated into specific-pathogen-free (SPF) embryonated chicken eggs for viral isolation. The results indicated that the positive rate of nucleic acid in enviromental samples exhibited seasonality. The positive rate of nucleic acid was significantly higher in Winter and Spring. The positive rate of nucleic acid in LPM located in the south of China was higher than in northern China. Samples of Sewage for cleaning poultry and chopping board showed that higher positive rate of nucleic acid than other samples. The Subtype identification showed that H5 and H9 were main subtypes in the enviromental samples. Viral isolation indicated H5 subtypes was more than H9 subtypes between 2009 and 2013 while H9 subtypes increased in 2013. Our findings suggested the significance of public health based on LPM surveillance and provided the basis of prevention and early warning for avian flu infection human.

  13. Prevalence of L. Monocytogenes in Environmental Samples Collected in Dairy Plants of Sassari Province, Italy

    PubMed Central

    Fadda, Antonio; Frongia, Giorgio; Sanna, Antonietta; Melillo, Rita

    2015-01-01

    Listeria (L.) monocytogenes is frequently isolated from food production environment and often persists in dairy plants despite vigorous sanitation regimes. In recent years several alert notifications were sent to Rapid Alert System for Food Products system as a consequence of Listeria monocytogenes contamination of ricotta cheese. After the alert of 2012, competent authority (Local Health Unit of Sassari Province) organised an environmental monitoring plan with the partnership of the Institute for Experimental Veterinary Medicine of Sardinia to verify analysis of dairy plants own-check according to Regulation (EC) N° 2073/05 and further modifications. In 2014 n. 665 processing areas samples of n. 50 dairy plants of Sassari Province were examined. UNI EN ISO 11290-1:2005 for detection of L. monocytogenes was used. Non-compliance in n. 5 diary plants are observed (n. 8 positive samples). Post-non-compliance environmental sanitisation was efficient and own-check plans included appropriate corrective actions. PMID:27800407

  14. A horizontal sampler for collection of water samples near the bottom

    USGS Publications Warehouse

    Joeris, Leonard S.

    1964-01-01

    The need to obtain adequate water samples immediately above a lake bottom or at a precisely defined depth is not new. The problem is of particular concern in a large section of central Lake Erie, where dissolved oxygen concentration may be reduced to 1 ppm or less in the hypolimnion and where the metalimnion frequently extends to or within 30 or 60 cm of the bottom (Becton 1963; Cam 1962).It is impossible to sample the hypolimnrtic waters satisfactorily with the usual Nanscn, Kemmerer, and Frautschy bottles (Carr 1962). Although the 500-ml sampler described here was designed, constructed, and used extensively and successfully to meet the particular problem in Lake Erie, it should be equally useful in a varirty of situations.

  15. Evaluation of surface sampling techniques for collection of Bacillus spores on common drinking water pipe materials.

    PubMed

    Packard, Benjamin H; Kupferle, Margaret J

    2010-01-01

    Drinking water utilities may face biological contamination of the distribution system from a natural incident or deliberate contamination. Determining the extent of contamination or the efficacy of decontamination is a challenge, because it may require sampling of the wetted surfaces of distribution infrastructure. This study evaluated two sampling techniques that utilities might use to sample exhumed pipe sections. Polyvinyl chloride (PVC), cement-lined ductile iron, and ductile iron pipe coupons (3 cm x 14 cm) cut from new water main piping were conditioned for three months in dechlorinated Cincinnati, Ohio tap water. Coupons were spiked with Bacillus atrophaeus subsp. globigii, a surrogate for Bacillus anthracis. Brushing and scraping were used to recover the inoculated spores from the coupons. Mean recoveries for all materials ranged from 37 +/- 30% to 43 +/- 20% for brushing vs. 24 +/- 10% to 51 +/- 29% for scraping. On cement-lined pipe, brushing yielded a significantly different recovery than scraping. No differences were seen between brushing and scraping the PVC and iron pipe coupons. Mean brushing and scraping recoveries from PVC coupons were more variable than mean recoveries from cement-lined and iron coupons. Spore retention differed between pipe materials and the presence of established biofilms also had an impact. Conditioned PVC coupons (with established biofilms) had significantly lower spore retention (31 +/- 11%) than conditioned cement-lined coupons (61 +/- 14%) and conditioned iron coupons (71 +/- 8%).

  16. Evaluation of a wipe surface sample method for collection of Bacillus spores from nonporous surfaces.

    PubMed

    Brown, Gary S; Betty, Rita G; Brockmann, John E; Lucero, Daniel A; Souza, Caroline A; Walsh, Kathryn S; Boucher, Raymond M; Tezak, Mathew; Wilson, Mollye C; Rudolph, Todd

    2007-02-01

    Polyester-rayon blend wipes were evaluated for efficiency of extraction and recovery of powdered Bacillus atrophaeus spores from stainless steel and painted wallboard surfaces. Method limits of detection were also estimated for both surfaces. The observed mean efficiency of polyester-rayon blend wipe recovery from stainless steel was 0.35 with a standard deviation of +/-0.12, and for painted wallboard it was 0.29 with a standard deviation of +/-0.15. Evaluation of a sonication extraction method for the polyester-rayon blend wipes produced a mean extraction efficiency of 0.93 with a standard deviation of +/-0.09. Wipe recovery quantitative limits of detection were estimated at 90 CFU per unit of stainless steel sample area and 105 CFU per unit of painted wallboard sample area. The method recovery efficiency and limits of detection established in this work provide useful guidance for the planning of incident response environmental sampling following the release of a biological agent such as Bacillus anthracis.

  17. Evaluation of a Wipe Surface Sample Method for Collection of Bacillus Spores from Nonporous Surfaces▿

    PubMed Central

    Brown, Gary S.; Betty, Rita G.; Brockmann, John E.; Lucero, Daniel A.; Souza, Caroline A.; Walsh, Kathryn S.; Boucher, Raymond M.; Tezak, Mathew; Wilson, Mollye C.; Rudolph, Todd

    2007-01-01

    Polyester-rayon blend wipes were evaluated for efficiency of extraction and recovery of powdered Bacillus atrophaeus spores from stainless steel and painted wallboard surfaces. Method limits of detection were also estimated for both surfaces. The observed mean efficiency of polyester-rayon blend wipe recovery from stainless steel was 0.35 with a standard deviation of ±0.12, and for painted wallboard it was 0.29 with a standard deviation of ±0.15. Evaluation of a sonication extraction method for the polyester-rayon blend wipes produced a mean extraction efficiency of 0.93 with a standard deviation of ±0.09. Wipe recovery quantitative limits of detection were estimated at 90 CFU per unit of stainless steel sample area and 105 CFU per unit of painted wallboard sample area. The method recovery efficiency and limits of detection established in this work provide useful guidance for the planning of incident response environmental sampling following the release of a biological agent such as Bacillus anthracis. PMID:17122390

  18. Biological sample collections from minors for genetic research: a systematic review of guidelines and position papers

    PubMed Central

    Hens, Kristien; Nys, Herman; Cassiman, Jean-Jacques; Dierickx, Kris

    2009-01-01

    Stored tissue samples are an important resource for epidemiological genetic research. Genetic research on biological material from minors can yield valuable information on the development and genesis of early-onset genetic disorders and the early interaction of environmental and genetic factors. The use of such tissue raises some specific ethical and governance questions, which are not completely covered by the discussion on biological materials from adults. We have retrieved 29 guidelines and position papers pertaining to the storage and use of biological tissue samples for genetic research, originating from 27 different organizations. Five documents have an international scope, three have an European scope and 21 have a national scope. We discovered that 11 of these documents did not contain a section on biological materials from minors. The content of the remaining 18 documents was categorized according to four themes: consent, principles of non-therapeutic research on vulnerable populations, ethics committee approval and difference between anonymous and identifiable samples. We found out that these themes are not consistently mentioned by each document, but that documents discussing the same themes were mostly in agreement with their recommendations. However, a systematic reflection on the ethical and policy issues arising from the participation of minors in biobank research is missing. PMID:19223929

  19. Comparison of Results for Quarter 1 Surface Water Split Samples Collected at the Nuclear Fuel Services Site, Erwin, Tennessee

    SciTech Connect

    David A. King, CHP, PMP

    2012-10-10

    Oak Ridge Associated Universities (ORAU), under the Oak Ridge Institute for Science and Education (ORISE) contract, collected split surface water samples with Nuclear Fuel Services (NFS) representatives on August 22, 2012. Representatives from the U.S. Nuclear Regulatory Commission and Tennessee Department of Environment and Conservation were also in attendance. Samples were collected at four surface water stations, as required in the approved Request for Technical Assistance number 11-018. These stations included Nolichucky River upstream (NRU), Nolichucky River downstream (NRD), Martin Creek upstream (MCU), and Martin Creek downstream (MCD). Both ORAU and NFS performed gross alpha and gross beta analyses. The comparison of results using the duplicate error ratio (DER), also known as the normalized absolute difference. A DER ≤ 3 indicates that, at a 99% confidence interval, split sample results do not differ significantly when compared to their respective one standard deviation (sigma) uncertainty. The NFS split sample report does not specify the confidence level of reported uncertainties. Therefore, standard two sigma reporting is assumed and uncertainty values were divided by 1.96. A comparison of split sample results, using the DER equation, indicates one set with a DER greater than 3. A DER of 3.1 is calculated for gross alpha results from ORAU sample 5198W0003 and NFS sample MCU-310212003. The ORAU result is 0.98 ± 0.30 pCi/L (value ± 2 sigma) compared to the NFS result of -0.08 ± 0.60 pCi/L. Relatively high DER values are not unexpected for low (e.g., background) analyte concentrations analyzed by separate laboratories, as is the case here. It is noted, however, NFS uncertainties are at least twice the ORAU uncertainties, which contributes to the elevated DER value. Differences in ORAU and NFS minimum detectable activities are even more pronounced. comparison of ORAU and NFS split samples produces reasonably consistent results for low (e.g., background

  20. Assessment of selected contaminants in streambed- and suspended-sediment samples collected in Bexar County, Texas, 2007-09

    USGS Publications Warehouse

    Wilson, Jennifer T.

    2011-01-01

    Elevated concentrations of sediment-associated contaminants are typically associated with urban areas such as San Antonio, Texas, in Bexar County, the seventh most populous city in the United States. This report describes an assessment of selected sediment-associated contaminants in samples collected in Bexar County from sites on the following streams: Medio Creek, Medina River, Elm Creek, Martinez Creek, Chupaderas Creek, Leon Creek, Salado Creek, and San Antonio River. During 2007-09, the U.S. Geological Survey periodically collected surficial streambed-sediment samples during base flow and suspended-sediment (large-volume suspended-sediment) samples from selected streams during stormwater runoff. All sediment samples were analyzed for major and trace elements and for organic compounds including halogenated organic compounds and polycyclic aromatic hydrocarbons (PAHs). Selected contaminants in streambed and suspended sediments in watersheds of the eight major streams in Bexar County were assessed by using a variety of methods—observations of occurrence and distribution, comparison to sediment-quality guidelines and data from previous studies, statistical analyses, and source indicators. Trace elements concentrations were low compared to the consensus-based sediment-quality guidelines threshold effect concentration (TEC) and probable effect concentration (PEC). Trace element concentrations were greater than the TEC in 28 percent of the samples and greater than the PEC in 1.5 percent of the samples. Chromium concentrations exceeded sediment-quality guidelines more frequently than concentrations of any other constituents analyzed in this study (greater than the TEC in 69 percent of samples and greater than the PEC in 8 percent of samples). Mean trace element concentrations generally are lower in Bexar County samples compared to concentrations in samples collected during previous studies in the Austin and Fort Worth, Texas, areas, but considering the relatively

  1. An investigation into the concurrent collection of human scent and epithelial skin cells using a non-contact sampling device.

    PubMed

    Caraballo, Norma Iris; Mendel, Julian; Holness, Howard; La Salvia, Joel; Moroose, Tina; Eckenrode, Brian; Stockham, Rex; Furton, Kenneth; Mills, DeEtta

    2016-09-01

    In criminal investigations, the collection of human scent often employs a non-contact, dynamic airflow device, known as the Scent Transfer Unit 100 (STU-100), to transfer volatile organic compounds (VOCs) from an object/person onto a collection material that is subsequently presented to human scent discriminating canines. Human scent is theorized to be linked to epithelial skin cells that are shed at a relatively constant rate allowing both scent and cellular material to be deposited into the environment and/or onto objects. Simultaneous collection of cellular material, with adequate levels of nuclear deoxyribonucleic acid (nDNA), and human scent using a non-invasive methodology would facilitate criminal investigations. This study evaluated the STU-100 for the concurrent collection of human scent and epithelial skin cells from a porous (paper) and non-porous (stainless steel bar) object that was held for a specified period of time in the dominant hand of twenty subjects (10 females and 10 males). Human scent analysis was performed using headspace static solid-phase microextraction with gas chromatography-mass spectrometry (HS-SPME/GC-MS). A polycarbonate filter was used to trap epithelial skin cells which, upon extraction, were subsequently analyzed, inter-laboratory, using the quantitative polymerase chain reaction (qPCR). The STU-100 proved to be inadequate for collecting the minimum number of epithelial skin cells required to obtain nuclear DNA concentrations above the limit of detection for the qPCR kit. With regard to its use for human scent collection, a reduction in the number and mass of compounds was observed when compared to samples that were directly collected. However, when the indirect collection of human scent from the two different objects was compared, a greater number and mass of compounds was observed from the non-porous object than from the porous object. This outcome suggests that the matrix composition of the scent source could affect the

  2. Vapor space characterization of waste Tank 241-BY-111: Results from samples collected on November 15, 1994

    SciTech Connect

    Lucke, R.B.; Ligotke, M.W.; McVeety, B.D.

    1995-06-01

    This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-BY-111 (referred to as Tank By-111). Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The target analytes for TO- 14 compounds were extended to include 14 analytes identified by the Toxicological Review Panel for Tank C-103 and reported by Mahlum et al. (1994). Program management included these analytes for future tank analyses as identified in the fiscal year work plan. This plan is attached to a letter dated 9/30/94 and addressed to Mr. T.J. Kelly of WHC. The plan also requires PNL to analyze for the permanent gases as shown in Table 3.7. The sample job was designated S4083, and samples wee collected by WHC on November 16, 1994, using the vapor sampling system (VSS). The results of the analyses are expected to be used to estimate the potential toxicity of tank-headspace gas as described in Data Quality Objectives for Generic In-Tank Health and Safety Vapor Issue Resolution, WHC-SD-WM-DQO-002, Rev. 0.

  3. Radioactivity measurements in moss (Hypnum cupressiforme) and lichen (Cladonia rangiformis) samples collected from Marmara region of Turkey.

    PubMed

    Belivermiş, Murat; Cotuk, Yavuz

    2010-11-01

    The present study was conducted to compare the (137)Cs, (40)K, (232)Th, and (238)U activity concentrations in epigeic moss (Hypnum cupressiforme) and lichen (Cladonia rangiformis). The activity levels in 37 moss and 38 lichen samples collected from the Marmara region of Turkey were measured using a gamma spectrometer equipped with a high purity germanium (HPGe) detector. The activity concentrations of (137)Cs, (40)K, (232)Th, and (238)U in the moss samples were found to be in the range of 0.36-8.13, 17.1-181.1, 1.51-6.17, and 0.87-6.70 Bq kg(-1) respectively, while these values were below detection limit (BDL)-4.32, 16.6-240.0, 1.32-6.47, and BDL-3.57 Bq kg(-1) respectively in lichen. The average moss/lichen activity ratios of (137)Cs, (40)K, (232)Th, and (238)U were found to be 1.32 +/- 0.57, 2.79 +/- 1.67, 2.11 +/- 0.82, and 2.19 +/- 1.02, respectively. Very low (137)Cs concentrations were observed in moss and lichen samples compared to soil samples collected from the same locations in a previous study. Seasonal variations of the measured radionuclide activities were also examined in the three sampling stations.

  4. Meteorites and Microbes: Meteorite Collection and Ice Sampling at Patriot Hills, Thiel Mountains, and South Pole, Antarctica

    NASA Technical Reports Server (NTRS)

    Sipiera, Paul P.; Hoover, Richard B.; Rose, M. Franklin (Technical Monitor)

    2000-01-01

    During the Antarctica 2000 Expedition, sponsored by the Planetary Studies Foundation, meteorites and ice microbiota were collected from the Patriot Hills, and Thiel Mountains of Antarctica and snow samples were at the South Pole. Psychrophilic and psychrotrophic microbiota were obtained from blue ice, cryoconite and ice-bubble systems. Twenty frozen meteorites were collected using aseptic techniques from the blue ice fields near the Moulton Escarpment of the Thiel Mountains (85 S, 94 W) and from the Morris Moraine of the Patriot Hills (80 S, 81 W) Ellsworth Mountains. These ice and meteorite samples are of potential significance to Astrobiology. They may help refine chemical and morphological biomarkers and refine characteristics of microbial life in one of the harshest environments on Earth. We discuss the Antarctica 2000 Expedition and provide preliminary results of the investigation of the meteorites and ice microbiota recovered.

  5. COMPARISON OF RESULTS FOR QUARTER 5 SURFACE WATER SPLIT SAMPLES COLLECTED AT THE NUCLEAR FUEL SERVICES SITE ERWIN TENNESSEE

    SciTech Connect

    2013-09-23

    Oak Ridge Associated Universities (ORAU), under the Oak Ridge Institute for Science and Education (ORISE) contract, collected split surface water samples with Nuclear Fuel Services (NFS) representatives on August 21, 2013. Representatives from the U.S. Nuclear Regulatory Commission (NRC) and the Tennessee Department of Environment and Conservation were also in attendance. Samples were collected at four surface water stations, as required in the approved Request for Technical Assistance number 11-018. These stations included Nolichucky River upstream (NRU), Nolichucky River downstream (NRD), Martin Creek upstream (MCU), and Martin Creek downstream (MCD). Both ORAU and NFS performed gross alpha and gross beta analyses, and the comparison of results using the duplicate error ratio (DER), also known as the normalized absolute difference, are tabulated. All DER values were less than 3 and results are consistent with low (e.g., background) concentrations.

  6. Geochemical data for core and bottom-sediment samples collected in 2007 from Grand Lake O' the Cherokees, northeast Oklahoma

    USGS Publications Warehouse

    Fey, David L.; Becker, Mark F.; and Smith, Kathleen S.

    2010-01-01

    Grand Lake O' the Cherokees is a large reservoir in northeast Oklahoma, below the confluence of the Neosho and Spring Rivers, both of which drain the Tri-State Mining District to the north. The Tri-State district covers an area of 1,200 mi2 (3,100 km2) and comprises Mississippi Valley-type lead-zinc deposits. A result of 120 years of mining activity is an estimated 75 million tons of processed mine tailings (chat) remaining in the district. Concerns of sediment quality and the possibility of human exposure to cadmium and lead through eating fish have led to several studies of the sediments in the Tri-State district. In order to record the transport and deposition of metals from the Tri-State district by the Spring and Neosho Rivers into Grand Lake O' the Cherokees, the U.S. Geological Survey collected 11 sediment cores and 15 bottom-sediment samples in September 2007. Subsamples from five selected cores and the bottom-sediment samples were analyzed for major and trace elements and forms of carbon. The sediment samples collected from the sediment-water interface had larger average concentrations of zinc, cadmium, and lead than local background. The core collected from the Spring River had the largest concentrations of mining-related elements. A core collected just south of Twin Bridges State Park, at the confluence of the Spring and Neosho Rivers, showed a mixing zone with more mining-related elements coming from the Spring River side. The element zinc showed the most definitive patterns in graphs depicting concentration-versus-depth profiles. A core collected from the main body of the reservoir showed affected sediment down to a depth of 85 cm (33 in). This core and two others appear to have penetrated to below mining-affected sediment.

  7. Quantitative x-ray diffraction phase analysis of coarse airborne particulate collected by cascade impactor sampling

    NASA Astrophysics Data System (ADS)

    Esteve, V.; Rius, J.; Ochando, L. E.; Amigó, J. M.

    Mineralogical composition of Castellon (Spanish Mediterranean coast) atmospheric aerosol was studied by X-ray diffraction by sampling with a cascade impactor without filters. Quantitative phase analysis of natural phases present in the atmospheric coarse aerosol was performed using a modified version of the computer program MENGE, that uses the standardless X-ray method developed by Rius for the quantitative analysis of multiphase mixtures, adapted for PC running. Presence of quartz, calcite and gypsum was identified in the atmospheric aerosol and we have quantified their amounts using the standardless method.

  8. The international Genome sample resource (IGSR): A worldwide collection of genome variation incorporating the 1000 Genomes Project data

    PubMed Central

    Clarke, Laura; Fairley, Susan; Zheng-Bradley, Xiangqun; Streeter, Ian; Perry, Emily; Lowy, Ernesto; Tassé, Anne-Marie; Flicek, Paul

    2017-01-01

    The International Genome Sample Resource (IGSR; http://www.internationalgenome.org) expands in data type and population diversity the resources from the 1000 Genomes Project. IGSR represents the largest open collection of human variation data and provides easy access to these resources. IGSR was established in 2015 to maintain and extend the 1000 Genomes Project data, which has been widely used as a reference set of human variation and by researchers developing analysis methods. IGSR has mapped all of the 1000 Genomes sequence to the newest human reference (GRCh38), and will release updated variant calls to ensure maximal usefulness of the existing data. IGSR is collecting new structural variation data on the 1000 Genomes samples from long read sequencing and other technologies, and will collect relevant functional data into a single comprehensive resource. IGSR is extending coverage with new populations sequenced by collaborating groups. Here, we present the new data and analysis that IGSR has made available. We have also introduced a new data portal that increases discoverability of our data—previously only browseable through our FTP site—by focusing on particular samples, populations or data sets of interest. PMID:27638885

  9. [Comparison of the determination of cyclosporin-A in blood samples collected on filter paper and by the ordinary technique].

    PubMed

    Azevedo, L S; Manrique, R; Sabbaga, E

    1995-01-01

    Monitoring cyclosporin-A (CsA) blood levels is of utmost importance for the rational use of this drug. Although many centers perform transplants, in Brazil there are few laboratories able to measure CsA blood levels. Therefore making blood samples reach the laboratory emerged as a problem. Collection of blood on filter paper has been a technique used for a long time in special cases. PURPOSE--To confirm the usefulness of measuring CsA blood levels in blood samples collected on filter paper and in the usual way. METHOD--We studied twenty renal cadaver kidney recipients who were receiving CsA, azathioprine and prednisone. Ninety five blood samples were collected and divided into two aliquots. One of them was sent routinely to one laboratory to perform whole blood CsA measurements. From the other aliquot, 20 microliters were pipetted on filter paper. When dried they were mailed to the other laboratory, where, after elution, CsA was measured. In both cases radioimmunoassay with polyclonal antibody was used. RESULTS--Linear correlation between both measurements revealed r = 0.81 with no statistical difference. CONCLUSION--The technique showed to be useful in clinical practice. In countries with continental size, as Brazil, it may be very helpful.

  10. Field Geologic Observation and Sample Collection Strategies for Planetary Surface Exploration: Insights from the 2010 Desert RATS Geologist Crewmembers

    NASA Technical Reports Server (NTRS)

    Hurtado, Jose M., Jr.; Young, Kelsey; Bleacher, Jacob E.; Garry, W. Brent; Rice, James W., Jr.

    2012-01-01

    Observation is the primary role of all field geologists, and geologic observations put into an evolving conceptual context will be the most important data stream that will be relayed to Earth during a planetary exploration mission. Sample collection is also an important planetary field activity, and its success is closely tied to the quality of contextual observations. To test protocols for doing effective planetary geologic field- work, the Desert RATS(Research and Technology Studies) project deployed two prototype rovers for two weeks of simulated exploratory traverses in the San Francisco volcanic field of northern Arizona. The authors of this paper represent the geologist crew members who participated in the 2010 field test.We document the procedures adopted for Desert RATS 2010 and report on our experiences regarding these protocols. Careful consideration must be made of various issues that impact the interplay between field geologic observations and sample collection, including time management; strategies relatedtoduplicationofsamplesandobservations;logisticalconstraintson the volume and mass of samples and the volume/transfer of data collected; and paradigms for evaluation of mission success. We find that the 2010 field protocols brought to light important aspects of each of these issues, and we recommend best practices and modifications to training and operational protocols to address them. Underlying our recommendations is the recognition that the capacity of the crew to flexibly execute their activities is paramount. Careful design of mission parameters, especially field geologic protocols, is critical for enabling the crews to successfully meet their science objectives.

  11. The international Genome sample resource (IGSR): A worldwide collection of genome variation incorporating the 1000 Genomes Project data.

    PubMed

    Clarke, Laura; Fairley, Susan; Zheng-Bradley, Xiangqun; Streeter, Ian; Perry, Emily; Lowy, Ernesto; Tassé, Anne-Marie; Flicek, Paul

    2017-01-04

    The International Genome Sample Resource (IGSR; http://www.internationalgenome.org) expands in data type and population diversity the resources from the 1000 Genomes Project. IGSR represents the largest open collection of human variation data and provides easy access to these resources. IGSR was established in 2015 to maintain and extend the 1000 Genomes Project data, which has been widely used as a reference set of human variation and by researchers developing analysis methods. IGSR has mapped all of the 1000 Genomes sequence to the newest human reference (GRCh38), and will release updated variant calls to ensure maximal usefulness of the existing data. IGSR is collecting new structural variation data on the 1000 Genomes samples from long read sequencing and other technologies, and will collect relevant functional data into a single comprehensive resource. IGSR is extending coverage with new populations sequenced by collaborating groups. Here, we present the new data and analysis that IGSR has made available. We have also introduced a new data portal that increases discoverability of our data-previously only browseable through our FTP site-by focusing on particular samples, populations or data sets of interest.

  12. Magnetical hollow fiber bar collection of extract in homogenous ionic liquid microextraction of triazine herbicides in water samples.

    PubMed

    Wang, Kun; Jiang, Jia; Kang, Mingqin; Li, Dan; Zang, Shuang; Tian, Sizhu; Zhang, Hanqi; Yu, Aimin; Zhang, Ziwei

    2017-04-01

    The homogeneous ionic liquid microextraction combined with magnetical hollow fiber bar collection was developed for extracting triazine herbicides from water samples. These analytes were separated and determined by high performance liquid chromatography. The triazines were quickly extracted into ionic liquid microdroplets dispersed in solution, and then these microdroplets were completely collected with magnetical hollow fiber bars; the pores of which were impregnated with hydrophobic ionic liquid, which makes the phase separation simplified with no need of centrifugation. Some experimental parameters, such as the type of ionic liquid, ultrasonic immersion time of hollow fiber, pH of sample solution, volume of hydrophilic ionic liquid, amount of ion-pairing agent NH4PF6, NaCl concentration, number of magnetical hollow fiber bar, stirring rate, and collection time were investigated and optimized. When the present method was applied to the analysis of real water samples, the precision and recoveries of six triazine herbicides vary from 0.1 to 9.2% and 73.4 to 118.5%, respectively. The detection limits for terbumeton, ametryn, prometryn, terbutryn, trietazine, and dimethametryn were 0.48, 0.15, 0.15, 0.14, 0.35, and 0.16 μg L(-1), respectively.

  13. Tank 241-C-112 headspace gas and vapor characterization results for samples collected in June 1994 and August 1994

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  14. Tank 241-BY-103 headspace gas and vapor characterization results for samples collected in May 1994 and November 1994

    SciTech Connect

    Bratzel, D.R.

    1995-09-26

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  15. Tank 241-TY-103 headspace gas and vapor characterization results for samples collected in August 1994 and April 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  16. Salivary Cortisol as a Biomarker of Stress in Mothers and their Low Birth Weight Infants and Sample Collecting Challenges

    PubMed Central

    Vujičić, Ana Đorđević; Đukić, Svjetlana Maglajić

    2016-01-01

    Summary Background Salivary cortisol measurement is a non-invasive method suitable for use in neonatal research. Mother-infant separation after birth represents stress and skin-to-skin contact (SSC) has numerous benefits. The aim of the study was to measure salivary cortisol in mothers and newborns before and after SSC in order to assess the effect of SSC on mothers’ and infants’ stress and to estimate the efficacy of collecting small saliva samples in newborns. Methods Salivary cortisol was measured in 35 mother-infant pairs before and after the first and the fifth SSC in small saliva samples (50 μL) using the high sensitivity Quantitative ELISA-Kit (0.0828 nmol/L) for low cortisol levels detection. Samples were collected with eye sponge during 3 to 5 minutes. Results Cortisol level in mothers decreased after SSC: the highest levels were measured before and the lowest after SSC and the differences in values were significant during both the first (p<0.001) and the fifth SSC (p<0.001). During the first SSC the cortisol level decrease was detected in 14 (40%) and an increase in 21 (60%) newborns, and during the fifth SSC a decrease was detected in 16 (45.7%) and an increase in 19 (54.3%) newborns, without confirmed significance of the difference. Saliva sampling efficacy using eye sponge was 75%. Conclusions Cortisol level decrease in mothers proves the stress reduction during SSC, while variable cortisol levels in infants do not indicate stress reduction and imply the need for further research. The used sampling method appeared to be one of the most optimal considering the sample volume, sampling time and efficacy.

  17. Geochemical Data for Samples Collected in 2007 Near the Concealed Pebble Porphyry Cu-Au-Mo Deposit, Southwest Alaska

    USGS Publications Warehouse

    Fey, David L.; Granitto, Matthew; Giles, Stuart A.; Smith, Steven M.; Eppinger, Robert G.; Kelley, Karen D.

    2008-01-01

    In the summer of 2007, the U.S. Geological Survey (USGS) began an exploration geochemical research study over the Pebble porphyry copper-gold-molydenum (Cu-Au-Mo) deposit in southwest Alaska. The Pebble deposit is extremely large and is almost entirely concealed by tundra, glacial deposits, and post-Cretaceous volcanic and volcaniclastic rocks. The deposit is presently being explored by Northern Dynasty Minerals, Ltd., and Anglo-American LLC. The USGS undertakes unbiased, broad-scale mineral resource assessments of government lands to provide Congress and citizens with information on national mineral endowment. Research on known deposits is also done to refine and better constrain methods and deposit models for the mineral resource assessments. The Pebble deposit was chosen for this study because it is concealed by surficial cover rocks, it is relatively undisturbed (except for exploration company drill holes), it is a large mineral system, and it is fairly well constrained at depth by the drill hole geology and geochemistry. The goals of the USGS study are (1) to determine whether the concealed deposit can be detected with surface samples, (2) to better understand the processes of metal migration from the deposit to the surface, and (3) to test and develop methods for assessing mineral resources in similar concealed terrains. This report presents analytical results for geochemical samples collected in 2007 from the Pebble deposit and surrounding environs. The analytical data are presented digitally both as an integrated Microsoft 2003 Access? database and as Microsoft 2003 Excel? files. The Pebble deposit is located in southwestern Alaska on state lands about 30 km (18 mi) northwest of the village of Illiamna and 320 km (200 mi) southwest of Anchorage (fig. 1). Elevations in the Pebble area range from 287 m (940 ft) at Frying Pan Lake just south of the deposit to 1146 m (3760 ft) on Kaskanak Mountain about 5 km (5 mi) to the west. The deposit is in an area of

  18. A Modified Catheterization Procedure to Reduce Bladder Damage when Collecting Urine Samples from Holstein Cows

    PubMed Central

    TAMURA, Tetsuo; NAKAMURA, Hiroshi; SATO, Say; SEKI, Makoto; NISHIKI, Hideto

    2014-01-01

    ABSTRACT This study proposed a modified procedure, using a small balloon catheter (SB catheter, 45 ml), for reducing bladder damage in cows. Holstein cows and the following catheters were prepared: smaller balloon catheter (XSB catheter; 30 ml), SB catheter and standard balloon catheter (NB catheter; 70 ml, as the commonly used, standard size). In experiment 1, each cow was catheterized. The occurrence of catheter-associated hematuria (greater than 50 RBC/HPF) was lower in the SB catheter group (0.0%, n=7) than in the NB catheter group (71.4%, n=7; P<0.05). In experiment 2, general veterinary parameters, urine pH, body temperature and blood values in cows were not affected before or after insertion of SB catheters (n=6). The incidence of urinary tract infection (UTI) was 3.0% per catheterized day (n=22). In experiment 3, feeding profiles, daily excretion of urinary nitrogen (P<0.05) and rate from nitrogen intake in urine (P<0.01), were higher with use of the SB catheter (n=13) than with the use of the vulva urine cup (n=18), indicating that using the SB catheter can provide accurate nutritional data. From this study, we concluded that when using an SB catheter, the following results occur; reduction in bladder damage without any veterinary risks and accuracy in regard to feeding parameters, suggesting this modified procedure using an SB catheter is a useful means of daily urine collection. PMID:24561376

  19. Quality Sample Collection, Handling, and Preservation for an Effective Microbial Forensics Program.

    SciTech Connect

    Budowle, Bruce; Schutzer, Steven E.; Burans, James P.; Beecher, Douglas J.; Cebulla, Thomas; Chakraborty, Ranjit; Cobb, William T.; Fletcher, Jacqueline; Hale, Martha L.; Harris, Robert B.; Heitkamp, Michael; Keller, Frederick P.; Kuske, Cheryl; LeClerc, Joseph E.; Marrone, Babetta L.; McKenna, Thomas S.; Morse, Stephen A.; Rodriguez, Luis L.; Valentine, Nancy B.; Yadev, Jagjit

    2006-10-01

    Science can be part of an effective investigative response to a bioterrorism event or a biocrime by providing capabilities to analyze biological and associated signatures in collected evidence. Microbial forensics, a discipline comprised of several scientific fields, is dedicated to the analysis of evidence from such criminal acts to help determine the responsible party and to exonerate the innocent. A partnership has been formed amount a number of government agencies, academia, and the private sector to better respond and deter potential perpetrators of bioterrorism or biocrimes. This partnership leverages our national scientific and analytical capabilities to support activities of law enforcement agencies. The Department of Homeland Security (DHS), whose mission is, in part, to respond to and to prevent acts of terrorism against the United States, has established the national Bioforensics Analysis Center (NBFAC). The NBFAC, in partnership with the FBI, (1) provides a state-of-the-art central laboratory for the analysis of microbial forensic evidence; and (2) serves as a nexus for integrating the national resources to increase the effectiveness of law enforcement in obtaining the highest level of attribution possible in criminal cases where the weapon is a biological agent.

  20. PCDD/F and metal concentrations in soil and herbage samples collected in the vicinity of a cement plant.

    PubMed

    Schuhmacher, M; Bocio, A; Agramunt, M C; Domingo, J L; de Kok, H A M

    2002-07-01

    In May 2000, the levels of a number of metals (As, Cd, Pb, Hg, Zn, Co, Cu, Mn, Sn, Tl, Cr, Ni and V) were determined in 16 soil and herbage samples collected in the vicinity of a cement plant from Sta. Margarida i els Monjos (Catalonia, Spain). Metal concentrations were also analyzed in air filters from three sampling stations placed nearthe facility. For most metals, concentrations were similar or even lower than previously reported values for other areas from Catalonia. On the other hand, the levels of polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDF) were also determined in four soil and 16 herbage samples. Mean values were 0.37 and 0.16 ng I-TEQ/kg for soils and herbage, respectively, values which in comparison with data from other surveys are rather low. No significant differences between metal and PCDD/F concentrations in samples collected at distances lower or greater than 3.5 km of the facility were noted. The current results show that the cement plant has a low impact on the metal and PCDD/F levels in the environment under direct influence of the facility. These results should be of interest to assess future temporal variations in the levels of metals and PCDD/Fs in this area.

  1. Trends in the levels of metals in soils and vegetation samples collected near a hazardous waste incinerator.

    PubMed

    Nadal, M; Bocio, A; Schuhmacher, M; Domingo, J L

    2005-10-01

    In 1998 and 2001, the levels of a number of elements (As, Be, Cd, Cr, Hg, Mn, Ni, Pb, Sn, Tl, and V) were determined in 40 soil and 40 herbage samples collected near a new hazardous waste incinerator (HWI) (Constantí, Catalonia, Spain). In 2003, soil and herbage samples were again collected at the same sampling points in which samples had been taken in the previous surveys. During the period 1998-2003, As, Be, Cr, Ni, and V levels showed significant increases in soils. In contrast, the levels of Cd, Hg, and Sn significantly decreased. With respect to herbage, while Cr, Mn, and V concentrations significantly increased, those of As levels diminished. On the other hand, human health risks derived from metal ingestion and inhalation of soils were also assessed. In relation to noncarcinogenic risks, all elements presented a value inside the safe interval. In turn, Cd and Cr were also in the safe interval of carcinogenic risks, whereas in contrast As levels clearly exceeded the regulatory limits concerning carcinogenic risks. According to the results of the previous (2001) and current (2003) surveys, the fluctuations in the metal concentrations suggest that the influence of the HWI is minimal in relation to other metal pollution sources in the area.

  2. A Low-Cost Method of Skin Swabbing for the Collection of DNA Samples from Small Laboratory Fish

    PubMed Central

    Breacker, Carl; Barber, Iain; Norton, William H.J.; McDearmid, Jonathan R.

    2017-01-01

    Abstract Fin clipping of live fish under anesthesia is widely used to collect samples for DNA extraction. An alternative, potentially less invasive, approach involves obtaining samples by swabbing the skin of nonanesthetized fish. However, this method has yet to be widely adopted for use in laboratory studies in the biological and biomedical sciences. Here, we compare DNA samples from zebrafish Danio rerio and three-spined sticklebacks Gasterosteus aculeatus collected via fin clipping and skin swabbing techniques, and test a range of DNA extraction methods, including commercially available kits and a lower-cost, in-house method. We verify the method for polymerase chain reaction analysis, and examine the potential risk of cross contamination between individual fish that are netted together. We show that swabbing, which may not require the use of anesthesia or analgesics, offers a reliable alternative to fin clipping. Further work is now required to determine the relative effects of fin clipping and swabbing on the stress responses and subsequent health of fish, and hence the potential of swabbing as a refinement to existing DNA sampling procedures. PMID:27788059

  3. COMPARISON OF RESULTS FOR QUARTER 2 SURFACE WATER SPLIT SAMPLES COLLECTED AT THE NUCLEAR FUEL SERVICES SITE, ERWIN, TENNESSEE

    SciTech Connect

    2013-01-21

    Oak Ridge Associated Universities (ORAU), under the Oak Ridge Institute for Science and Education (ORISE) contract, collected split surface water samples with Nuclear Fuel Services (NFS) representatives on November 15, 2012. Representatives from the U.S. Nuclear Regulatory Commission and Tennessee Department of Environment and Conservation were also in attendance. Samples were collected at four surface water stations, as required in the approved Request for Technical Assistance number 11-018. These stations included Nolichucky River upstream (NRU), Nolichucky River downstream (NRD), Martin Creek upstream (MCU), and Martin Creek downstream (MCD). Both ORAU and NFS performed gross alpha and gross beta analyses, and the results are compared using the duplicate error ratio (DER), also known as the normalized absolute difference. A DER {<=} 3 indicates that, at a 99% confidence interval, split sample results do not differ significantly when compared to their respective one standard deviation (sigma) uncertainty (ANSI N42.22). The NFS split sample report does not specify the confidence level of reported uncertainties (NFS 2012). Therefore, standard two sigma reporting is assumed and uncertainty values were divided by 1.96. In conclusion, all DER values were less than 3 and results are consistent with low (e.g., background) concentrations.

  4. Protocol for the collection and analysis of volatile POHCs (Principal Organic Hazardous Constituents) using VOST (Volatile Organic Sampling Train)

    NASA Astrophysics Data System (ADS)

    Hansen, E. M.

    1984-03-01

    An operating protocol for sampling and analysis of voltatile organic constituents of flue gas from hazardous waste incinerators or other similar combustor systems using the Volatile Organic Sampling Train (VOST) is presented. It is intended to be used for guidance by personnel of the regulatory groups, personnel associated with engineering research and development, and the regulated community. The document is in two parts. Part A describes the key components of the train, the procedures for preparing the sorbent materials, and procedures for sample collection using the VOST. Part B describes the procedures for analyzing VOST sorbent cartridges for volatile principal organic hazardous constituents (POHCs) using purge-trap-desorb gas chromatography/mass spectrometry (P-T-D GC/MS). Quality control procedures are presented in both parts.

  5. Target recognition by maximizing heterogeneity of signal samples collected for discrimination with respect to an observed signal

    NASA Astrophysics Data System (ADS)

    Nechval, Nicholas A.

    1995-07-01

    This paper deals with the problem of how to identify targets or signals in noise, which represents, mathematically, the problem of classifying an observed target data sample as coming from one of several populations. Some of the information about the alternative distributions of populations has been obtained from signal data samples collected for discrimination. Each sample is declared to be realization of a specific stochastic process. By this step each sample is attached to just one out of a set of possible signals with distinct characteristics. We are dealing with the case when the alternative distributions of populations are multivariate normal with different mean vectors and covariance matrices. It is assumed that all parameters are unknown. Also, the univariate case is considered. It is shown how certain tests of homogeneity or normality of several samples of the data can be used to transform a set of signal data samples into some statistic that measures either distance from homogeneity or distance from normality of these samples, respectively. This statistic is then used to construct sample based discriminant rule which either maximizes distance from homogeneity or minimizes distance from normality, respectively, with respect to an observed signal. The above discriminant rules are applied to obtain new procedures of target recognition which are relatively simple to carry out and can be easily used, say, for bird recognition by radar in order to preclude the possibility of collisions between aircraft and birds, etc. In those situations when we deal with small samples of the data, the procedures proposed herein are recommended. An illustrative numerical example is given.

  6. Laboratory evaluation of sample collection methods (organs vs swabs) for Tasmanian salmon reovirus detection in farmed Atlantic salmon, Salmo salar L.

    PubMed

    Zainathan, S C; Carson, J; Crane, M St J; Nowak, B F

    2013-04-01

    The use of swabs relative to organs as a sample collection method for the detection of Tasmanian salmon reovirus (TSRV) in farmed Tasmanian Atlantic salmon, Salmo salar L., was evaluated by RT-qPCR. Evaluation of individual and pooled sample collection (organs vs swabs) was carried out to determine the sensitivity of the collection methods and the effect of pooling of samples for the detection of TSRV. Detection of TSRV in individual samples was as sensitive when organs were sampled compared to swabs, and in pooled samples, organs demonstrated a sensitivity of one 10-fold dilution higher than sampling of pooled swabs. Storage of swabs at 4 °C for t = 24 h demonstrated results similar to those at t = 0. Advantages of using swabs as a preferred sample collection method for the detection of TSRV compared to organ samples are evident from these experimental trials.

  7. Melting Temperature Mapping Method: A Novel Method for Rapid Identification of Unknown Pathogenic Microorganisms within Three Hours of Sample Collection

    PubMed Central

    Niimi, Hideki; Ueno, Tomohiro; Hayashi, Shirou; Abe, Akihito; Tsurue, Takahiro; Mori, Masashi; Tabata, Homare; Minami, Hiroshi; Goto, Michihiko; Akiyama, Makoto; Yamamoto, Yoshihiro; Saito, Shigeru; Kitajima, Isao

    2015-01-01

    Acquiring the earliest possible identification of pathogenic microorganisms is critical for selecting the appropriate antimicrobial therapy in infected patients. We herein report the novel “melting temperature (Tm) mapping method” for rapidly identifying the dominant bacteria in a clinical sample from sterile sites. Employing only seven primer sets, more than 100 bacterial species can be identified. In particular, using the Difference Value, it is possible to identify samples suitable for Tm mapping identification. Moreover, this method can be used to rapidly diagnose the absence of bacteria in clinical samples. We tested the Tm mapping method using 200 whole blood samples obtained from patients with suspected sepsis, 85% (171/200) of which matched the culture results based on the detection level. A total of 130 samples were negative according to the Tm mapping method, 98% (128/130) of which were also negative based on the culture method. Meanwhile, 70 samples were positive according to the Tm mapping method, and of the 59 suitable for identification, 100% (59/59) exhibited a “match” or “broad match” with the culture or sequencing results. These findings were obtained within three hours of whole blood collection. The Tm mapping method is therefore useful for identifying infectious diseases requiring prompt treatment. PMID:26218169

  8. Capture and exploration of sample quality data to inform and improve the management of a screening collection.

    PubMed

    Charles, Isabel; Sinclair, Ian; Addison, Daniel H

    2014-04-01

    A new approach to the storage, processing, and interrogation of the quality data for screening samples has improved analytical throughput and confidence and enhanced the opportunities for learning from the accumulating records. The approach has entailed the design, development, and implementation of a database-oriented system, capturing information from the liquid chromatography-mass spectrometry capabilities used for assessing the integrity of samples in AstraZeneca's screening collection. A Web application has been developed to enable the visualization and interactive annotation of the analytical data, monitor the current sample queue, and report the throughput rate. Sample purity and identity are certified automatically on the chromatographic peaks of interest if predetermined thresholds are reached on key parameters. Using information extracted in parallel from the compound registration and container inventory databases, the chromatographic and spectroscopic profiles for each vessel are linked to the sample structures and storage histories. A search engine facilitates the direct comparison of results for multiple vessels of the same or similar compounds, for single vessels analyzed at different time points, or for vessels related by their origin or process flow. Access to this network of information has provided a deeper understanding of the multiple factors contributing to sample quality assurance.

  9. Melting Temperature Mapping Method: A Novel Method for Rapid Identification of Unknown Pathogenic Microorganisms within Three Hours of Sample Collection.

    PubMed

    Niimi, Hideki; Ueno, Tomohiro; Hayashi, Shirou; Abe, Akihito; Tsurue, Takahiro; Mori, Masashi; Tabata, Homare; Minami, Hiroshi; Goto, Michihiko; Akiyama, Makoto; Yamamoto, Yoshihiro; Saito, Shigeru; Kitajima, Isao

    2015-07-28

    Acquiring the earliest possible identification of pathogenic microorganisms is critical for selecting the appropriate antimicrobial therapy in infected patients. We herein report the novel "melting temperature (Tm) mapping method" for rapidly identifying the dominant bacteria in a clinical sample from sterile sites. Employing only seven primer sets, more than 100 bacterial species can be identified. In particular, using the Difference Value, it is possible to identify samples suitable for Tm mapping identification. Moreover, this method can be used to rapidly diagnose the absence of bacteria in clinical samples. We tested the Tm mapping method using 200 whole blood samples obtained from patients with suspected sepsis, 85% (171/200) of which matched the culture results based on the detection level. A total of 130 samples were negative according to the Tm mapping method, 98% (128/130) of which were also negative based on the culture method. Meanwhile, 70 samples were positive according to the Tm mapping method, and of the 59 suitable for identification, 100% (59/59) exhibited a "match" or "broad match" with the culture or sequencing results. These findings were obtained within three hours of whole blood collection. The Tm mapping method is therefore useful for identifying infectious diseases requiring prompt treatment.

  10. Seed germination from lowland tapir (Tapirus terrestris) fecal samples collected during the dry season in the Northern Brazilian Amazon.

    PubMed

    Barcelos, Adriana Renata; Bobrowiec, Paulo Estefano D; Sanaiotti, Tânia Margarete; Gribel, Rogério

    2013-03-01

    This study evaluated the potential of lowland tapirs as seed dispersers in the northern Brazilian Amazon. The study analyzed the viability of seeds after passage through the gut. Fecal samples were collected from 6 different vegetation physiognomies in Viruá National Park during the dry season. The samples were then kept in a greenhouse for 16 months to allow the seeds to germinate. The seedling species were identified and classified according to the type of fruit, plant habit, seed size and type of ingestion. Of the 111 fecal samples, 94 (84.7%) had viable seeds of 75 species. Melastomataceae was the most frequent family with viable seeds in the fecal samples (69.1% of samples, N= 18 species). The data suggest that the importance of the lowland tapirs as dispersers is not restricted to the species consumed actively by frugivory but also extends to species accidentally consumed during browsing. The occurrence of both large and small viable seeds in the fecal samples as well as a number of large drupes, which probably cannot be transported via endozoochory by any other animal species, provide evidence of the ecological importance of lowland tapirs to the dynamics of the forest-campinarana vegetation mosaic in the region.

  11. Tank 241-U-104 headspace gas and vapor characterization results from samples collected on July 16, 1996

    SciTech Connect

    Pool, K.H.; Evans, J.C.; Hayes, J.C.; Mitroshkov, A.V.; Edwards, J.A.; Julya, J.L.; Thornton, B.M.; Fruchter, J.S.; Silvers, K.L.

    1997-08-01

    This report presents the results from analyses of samples taken from the headspace of waste storage tank 241-U-104 (Tank U-104) at the Hanford Site in Washington State. Tank headspace samples collected by Westinghouse Hanford Company (WHC) were analyzed by Pacific Northwest National Laboratory (PNNL) to determine headspace concentrations of selected non-radioactive analytes. Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Vapor concentrations from sorbent trap samples are based on measured sample volumes provided by WHC. No analytes were determined to be above the immediate notification limits specified by the sampling and analysis plan. None of the flammable constituents were present at concentrations above the analytical instrument detection limits. Total headspace flammability was estimated to be <0.108% of the lower flammability limit. Average measured concentrations of targeted gases, inorganic vapors, and selected organic vapors are provided in a table. A summary of experimental methods, including sampling methodology, analytical procedures, and quality assurance and control methods are presented in Section 2.0. Detailed descriptions of the analytical results are provided in Section 3.0.

  12. Simple Method for High-Sensitivity Determination of Cosmogenic (35)S in Snow and Water Samples Collected from Remote Regions.

    PubMed

    Lin, Mang; Wang, Kun; Kang, Shichang; Thiemens, Mark H

    2017-03-15

    Cosmogenic (35)S is useful in understanding a wide variety of chemical and physical processes in the atmosphere, the hydrosphere, and the cryosphere. The 87.4-day half-life and the ubiquity of sulfur in natural environments renders it an ideal tracer of many phenomena. Measurements of (35)S in snow and water samples are scarce as existing analytical methods require a large volume of sample (>20 L) due to their high analytical activity background and low counting efficiency. Here, we present a new set of snow/water sample collecting and handling procedures for high-sensitivity determination of cosmogenic (35)S using a low-level liquid scintillation spectrometer. Laboratory experiments using diluted (35)S standards (with activities of <5 disintegrations per minute) showed a (35)S recovery percentage of ∼95%, demonstrating a relatively small deviation from the true value. Using this method, we successfully measured (35)S in ∼1 L of fresh snow sample collected from a glacier on the Tibetan Plateau to be 47 ± 7 mBq/L. On the basis of (35)S activities in 9 natural samples measured in this study, a first proof-of-concept approximation for age determinations and source attributions was presented. This new method will provide a powerful tool in studying (35)S in small volumes of snow and water samples, especially those from remote but climatically important regions such as the polar regions and the Tibetan Plateau and Himalayas. The measurements are particularly important as the radioactive sulfur provides an actual clock of glacial melting processes. With the growing rate of glacial loss, the need for measurements from remote locations becomes all the more important.

  13. COMPARISON OF RESULTS FOR QUARTER 4 SURFACE WATER SPLIT SAMPLES COLLECTED AT THE NUCLEAR FUELS SERVICES SITE, ERWIN, TN

    SciTech Connect

    none,

    2013-08-15

    Oak Ridge Associated Universities (ORAU), under the Oak Ridge Institute for Science and Education (ORISE) contract, collected split surface water samples with Nuclear Fuel Services (NFS) representatives on June 12, 2013. Representatives from the U.S. Nuclear Regulatory Commission (NRC) and the Tennessee Department of Environment and Conservation were also in attendance. Samples were collected at four surface water stations, as required in the approved Request for Technical Assistance number 11-018. These stations included Nolichucky River upstream (NRU), Nolichucky River downstream (NRD), Martin Creek upstream (MCU), and Martin Creek downstream (MCD). Both ORAU and NFS performed gross alpha and gross beta analyses, and Table 1 presents the comparison of results using the duplicate error ratio (DER), also known as the normalized absolute difference. A DER ≤ 3 indicates at a 99% confidence interval that split sample results do not differ significantly when compared to their respective one standard deviation (sigma) uncertainty (ANSI N42.22). The NFS split sample report specifies 95% confidence level of reported uncertainties (NFS 2013). Therefore, standard two sigma reporting values were divided by 1.96. In conclusion, most DER values were less than 3 and results are consistent with low (e.g., background) concentrations. The gross beta result for sample 5198W0014 was the exception. The ORAU gross beta result of 6.30 ± 0.65 pCi/L from location NRD is well above NFS's non-detected result of 1.56 ± 0.59 pCi/L. NFS's data package includes no detected result for any radionuclide at location NRD. At NRC's request, ORAU performed gamma spectroscopic analysis of sample 5198W0014 to identify analytes contributing to the relatively elevated gross beta results. This analysis identified detected amounts of naturally-occurring constituents, most notably Ac-228 from the thorium decay series, and does not suggest the presence of site-related contamination.

  14. Collecting Samples of Coronal and Solar Wind Plasma with Solar Probe Plus

    NASA Astrophysics Data System (ADS)

    Kasper, J. C.; Solar Wind Electrons Alphas; Protons (Sweap) Team

    2011-12-01

    The primary science objective of the NASA Solar Probe Plus mission is to determine the structure and dynamics of the Sun's coronal magnetic field and to understand how the corona and solar wind are heated and accelerated and how energetic particles are produced and evolve. To accomplish this, the spacecraft carries a broad payload of in situ and remote sensing instruments and uses a sequence of Venus gravitational assists to dive within 8.5 solar radii of the surface of the Sun, making it the first spacecraft to enter the sub-Alfvénic solar corona. This talk will focus on measurements of the thermal ions and electrons that constitute the bulk of the solar corona and solar wind, covering open questions related to the structure, heating, and acceleration of the solar corona and solar wind. The Solar Wind Electrons Alphas and Protons (SWEAP) Investigation on Solar Probe Plus will be presented, including a description of how measurements from electrostatic analyzers behind the heat shield and a Sun-viewing Faraday Cup are combined to ensure continuous and comprehensive sampling of the corona and wind throughout each encounter. Opportunities for coordinated observations with other spacecraft and ground-based observatories will be presented, along with a discussion of possible contributions from the theory and modeling communities, and from existing observations, as we prepare for this historic mission.

  15. Designing and implementing sample and data collection for an international genetics study: the Type 1 Diabetes Genetics Consortium (T1DGC)

    PubMed Central

    Hilner, Joan E; Perdue, Letitia H; Sides, Elizabeth G; Pierce, June J; Wägner, Ana M; Aldrich, Alan; Loth, Amanda; Albret, Lotte; Wagenknecht, Lynne E; Nierras, Concepcion; Akolkar, Beena

    2010-01-01

    Background and Purpose The Type 1 Diabetes Genetics Consortium (T1DGC) is an international project whose primary aims are to: (a) discover genes that modify type 1 diabetes risk; and (b) expand upon the existing genetic resources for type 1 diabetes research. The initial goal was to collect 2500 affected sibling pair (ASP) families worldwide. Methods T1DGC was organized into four regional networks (Asia-Pacific, Europe, North America, and the United Kingdom) and a Coordinating Center. A Steering Committee, with representatives from each network, the Coordinating Center, and the funding organizations, was responsible for T1DGC operations. The Coordinating Center, with regional network representatives, developed study documents and data systems. Each network established laboratories for: DNA extraction and cell line production; human leukocyte antigen genotyping; and autoantibody measurement. Samples were tracked from the point of collection, processed at network laboratories and stored for deposit at National Institute for Diabetes and Digestive and Kidney Diseases (NIDDK) Central Repositories. Phenotypic data were collected and entered into the study database maintained by the Coordinating Center. Results T1DGC achieved its original ASP recruitment goal. In response to research design changes, the T1DGC infrastructure also recruited trios, cases, and controls. Results of genetic analyses have identified many novel regions that affect susceptibility to type 1 diabetes. T1DGC created a resource of data and samples that is accessible to the research community. Limitations Participation in T1DGC was declined by some countries due to study requirements for the processing of samples at network laboratories and/or final deposition of samples in NIDDK Central Repositories. Re-contact of participants was not included in informed consent templates, preventing collection of additional samples for functional studies. Conclusions T1DGC implemented a distributed

  16. Detection of triazole deicing additives in soil samples from airports with low, mid, and large volume aircraft deicing activities.

    PubMed

    McNeill, K S; Cancilla, D A

    2009-03-01

    Soil samples from three USA airports representing low, mid, and large volume users of aircraft deicing fluids (ADAFs) were analyzed by LC/MS/MS for the presence of triazoles, a class of corrosion inhibitors historically used in ADAFs. Triazoles, specifically the 4-methyl-1H-benzotriazole and the 5-methyl-1H-benzotriazole, were detected in a majority of samples and ranged from 2.35 to 424.19 microg/kg. Previous studies have focused primarily on ground and surface water impacts of larger volume ADAF users. The detection of triazoles in soils at low volume ADAF use airports suggests that deicing activities may have a broader environmental impact than previously considered.

  17. Electrofishing and the effects of depletion sampling on fish health: A review and recommendations for additional study

    USGS Publications Warehouse

    Panek, F.M.; Densmore, Christine L.; Cipriano, R.C.; Bruckner, A.W.; Shchelkunov, I.S.

    2011-01-01

    Depletion sampling in combination with multiple-pass electrofishing is an important fisheries management tool for wadeable streams. This combination of techniques has been used routinely by federal and state fishery management agencies for several decades as a reliable means to obtain quantitative data on trout populations or to describe fish community structure. In this paper we review the effects of electrofishing on fish and discuss this within the context of depletion sampling and multiple exposures of fishes to electric fields. The multiple wave forms most commonly used in sampling (alternating current, direct current, and pulsed direct current) are discussed as well as electrofishing induced response, injury and physiological stress. Fish that survive electrofishing injuries are more likely to suffer short and long-term adverse effects to their behavior, health, growth, or reproduction. Of greatest concern are the native, non-target species that may be subjected to multiple electrical shocks during the course of a 3-pass depletion survey. These exposures and their effects on the non-target species warrant further study as do the overall effects of electrofishing on populations and community structure. 

  18. Diagnosis of Clostridium difficile infection: comparison of four methods on specimens collected in Cary-Blair transport medium and tcdB PCR on fresh versus frozen samples.

    PubMed

    Brown, Noah A; Lebar, William D; Young, Carol L; Hankerd, Rosemary E; Newton, Duane W

    2011-03-08

    Clostridium difficile infection (CDI) caused by toxigenic strains of C. difficile is primarily a nosocomial infection with increasing prevalence. Stool specimens are typically collected in Cary-Blair transport medium to maximize culture-based detection of common stool pathogens. The goal of this study was to establish an analytically accurate and efficient algorithm for the detection of CDI in our patient population using samples collected in Cary-Blair transport medium. In addition, we wished to determine whether the sensitivity and specificity of PCR was affected by freezing samples before testing. Using 357 specimens, we compared four methods: enzyme immunoassay for the antigen glutamate dehydrogenase (Wampole™ C. DIFF CHEK-60 Assay, GDH), toxin A and B enzyme immunoassay (Remel ProSpecT™ C. difficile Toxin A/B Microplate Assay, Toxin EIA), cell culture cytotoxicity neutralization assay (Bartels™ Cytotoxicity Assay, CT), and real-time PCR targeting the toxin B gene (BD GeneOhm™ Cdiff Assay, PCR). The analytic sensitivity and specificity of each as determined using a combined gold standard were as follows: GDH, 100% and 93.2%; Toxin EIA, 82.9% and 82.9%; CT, 100% and 100%; PCR (performed on frozen specimens) 74.3% and 96.6%; respectively. However, the sensitivity and specificity of PCR improved to 100% when performed on 50 fresh stool samples collected in Cary-Blair. While CT remains a sensitive method for the detection of CDI, GDH offers an excellent initial screening method to rule out CDI. While the performance of each assay did not appear to be affected by collection in Cary-Blair medium, PCR performed better using fresh specimens.

  19. Diagnosis of Clostridium difficile infection: comparison of four methods on specimens collected in Cary-Blair transport medium and tcdB PCR on fresh versus frozen samples

    PubMed Central

    Brown, Noah A.; LeBar, William D.; Young, Carol L.; Hankerd, Rosemary E.; Newton, Duane W.

    2011-01-01

    Clostridium difficile infection (CDI) caused by toxigenic strains of C. difficile is primarily a nosocomial infection with increasing prevalence. Stool specimens are typically collected in Cary-Blair transport medium to maximize culture-based detection of common stool pathogens. The goal of this study was to establish an analytically accurate and efficient algorithm for the detection of CDI in our patient population using samples collected in Cary-Blair transport medium. In addition, we wished to determine whether the sensitivity and specificity of PCR was affected by freezing samples before testing. Using 357 specimens, we compared four methods: enzyme immunoassay for the antigen glutamate dehydrogenase (Wampole™ C. DIFF CHEK-60 Assay, GDH), toxin A and B enzyme immunoassay (Remel ProSpecT™ C. difficile Toxin A/B Microplate Assay, Toxin EIA), cell culture cytotoxicity neutralization assay (Bartels™ Cytotoxicity Assay, CT), and real-time PCR targeting the toxin B gene (BD GeneOhm™ Cdiff Assay, PCR). The analytic sensitivity and specificity of each as determined using a combined gold standard were as follows: GDH, 100% and 93.2%; Toxin EIA, 82.9% and 82.9%; CT, 100% and 100%; PCR (performed on frozen specimens) 74.3% and 96.6%; respectively. However, the sensitivity and specificity of PCR improved to 100% when performed on 50 fresh stool samples collected in Cary-Blair. While CT remains a sensitive method for the detection of CDI, GDH offers an excellent initial screening method to rule out CDI. While the performance of each assay did not appear to be affected by collection in Cary-Blair medium, PCR performed better using fresh specimens. PMID:24470904

  20. Vanilmandelic acid and homovanillic acid levels in patients with neural crest tumor: 24-hour urine collection versus random sample.

    PubMed

    Gregianin, L J; McGill, A C; Pinheiro, C M; Brunetto, A L

    1997-01-01

    Neuroblastoma is the most common solid tumor in childhood and is the most frequent neural crest tumor (NCT). More than 90% of the patients excrete high levels of vanilmandelic acid (VMA) and homovanillic acid (HVA) in the urine. Original biochemical methods for measuring these two metabolites of catecholamines employed a collection of urine for 24 hours to avoid errors related to circadian cycle variations. More recently, attempts have been made to replace the 24-hour collections by random samples (RSs). This has practical advantages particularly for young children. The objective of this study is to assess whether urinary VMA related to urinary creatinine levels can be determined reliably by the method of Pisano et al. from RSs in patients with NCT. The determination of the consumption of VMA in urine stored for prolonged periods of time was also studied. We found a good correlation between the values of metabolites of catecholamines in RSs compared with 24-hour urine collections. There was consumption of VMA in urine samples after storage. We conclude that determination of VMA in RSs of urine by Pisano's method may identify NCT production of catecholamines and that the consumption of these catecholamines is an important factor to consider in the interpretation of values obtained with stored urine specimens.

  1. Evaluation of vacuum filter sock surface sample collection method for Bacillus spores from porous and non-porous surfaces.

    PubMed

    Brown, Gary S; Betty, Rita G; Brockmann, John E; Lucero, Daniel A; Souza, Caroline A; Walsh, Kathryn S; Boucher, Raymond M; Tezak, Matthew S; Wilson, Mollye C

    2007-07-01

    Vacuum filter socks were evaluated for recovery efficiency of powdered Bacillus atrophaeus spores from two non-porous surfaces, stainless steel and painted wallboard and two porous surfaces, carpet and bare concrete. Two surface coupons were positioned side-by-side and seeded with aerosolized Bacillus atrophaeus spores. One of the surfaces, a stainless steel reference coupon, was sized to fit into a sample vial for direct spore removal, while the other surface, a sample surface coupon, was sized for a vacuum collection application. Deposited spore material was directly removed from the reference coupon surface and cultured for enumeration of colony forming units (CFU), while deposited spore material was collected from the sample coupon using the vacuum filter sock method, extracted by sonication and cultured for enumeration. Recovery efficiency, which is a measure of overall transfer effectiveness from the surface to culture, was calculated as the number of CFU enumerated from the filter sock sample per unit area relative to the number of CFU enumerated from the co-located reference coupon per unit area. The observed mean filter sock recovery efficiency from stainless steel was 0.29 (SD = 0.14, n = 36), from painted wallboard was 0.25 (SD = 0.15, n = 36), from carpet was 0.28 (SD = 0.13, n = 40) and from bare concrete was 0.19 (SD = 0.14, n = 44). Vacuum filter sock recovery quantitative limits of detection were estimated at 105 CFU m(-2) from stainless steel and carpet, 120 CFU m(-2) from painted wallboard and 160 CFU m(-2) from bare concrete. The method recovery efficiency and limits of detection established in this work provide useful guidance for the planning of incident response environmental sampling for biological agents such as Bacillus anthracis.

  2. Sample collection, preservation and submittal procedures for 10 CFR 50 and 10 CFR 50 and 10 CFR 61 nuclear power plant matrices

    SciTech Connect

    Banavali, A.D.; Moreno, E.M.; McCurdy, D.E.

    1994-12-31

    Sample collection, preservation and submittal procedures are described here for nuclear power plant 10 CFR 50 and 10 CFR 61 samples. While sample collection procedures should ensure that a sample reflects the true media type from a homogeneity standpoint, sample preservation is absolutely necessary to prevent the adsorption of analytes occurring on the walls of the container. After sample collection and preservation, the samples should be shipped to the radioanalytical laboratory as soon as possible to reduce the magnitude of analyte adsorption on the walls of the container. When samples are shipped for analysis, sample transmittal forms should be properly filled out to ensure that instructions are clear as to the isotopic analysis requested and the weight/volume of sample shipped, minimum detectable concentration (MDC) required, station code, etc.

  3. Evaluation of a commercial real-time PCR kit for detection of dengue virus in samples collected during an outbreak in Goiania, Central Brazil, in 2005.

    PubMed

    Levi, José Eduardo; Tateno, Adriana Fumie; Machado, Adriana Freire; Ramalho, Débora Camillo; de Souza, Vanda Akico Ueda Fick; Guilarde, Adriana Oliveira; de Rezende Feres, Valéria Christina; Martelli, Celina Maria Turchi; Turchi, Marília Dalva; Siqueira, João Bosco; Pannuti, Cláudio Sérgio

    2007-06-01

    In the past 2 decades, dengue has reemerged in Brazil as a significant public health problem. Clinicians demand a diagnostic test with high sensitivity that is applicable during the early symptomatic phase. We aimed to test two distinct molecular methods on samples from suspected dengue cases during an outbreak in Central Brazil. Acute-phase serum specimens from 254 patients suspected of having dengue were collected during 2005 in the city of Goiânia, Central Brazil. Samples were blindly evaluated by real-time and multiplex PCR in addition to routine immunoglobulin M serology and virus culture. Overall, acute dengue was confirmed by serology, multiplex PCR, or virus isolation for 80% of patients (203/254). Another four patients presented real-time PCR-positive results as the unique marker of dengue. Higher real-time PCR positivity levels and viral loads were observed in the early symptomatic phase of disease (< or =5 days) than after this period. Multiplex and real-time PCR assays presented a high kappa agreement (0.85). According to multiplex PCR, 60 samples harbored dengue virus type 3 (DEN-3), 4 samples harbored DEN-2, and 1 sample displayed a pattern compatible with a double infection with DEN-2 and -3. The dengue virus real-time kit was found to be practical and adjustable for high throughput, to display the best performance in the early symptomatic phase of dengue cases, and to be valuable for confirming dengue diagnosis in a timely manner.

  4. Temperature accelerated Monte Carlo (TAMC): a method for sampling the free energy surface of non-analytical collective variables.

    PubMed

    Ciccotti, Giovanni; Meloni, Simone

    2011-04-07

    We introduce a new method to simulate the physics of rare events. The method, an extension of the Temperature Accelerated Molecular Dynamics, comes in use when the collective variables introduced to characterize the rare events are either non-analytical or so complex that computing their derivative is not practical. We illustrate the functioning of the method by studying the homogeneous crystallization in a sample of Lennard-Jones particles. The process is studied by introducing a new collective variable that we call Effective Nucleus Size N. We have computed the free energy barriers and the size of critical nucleus, which result in agreement with data available in the literature. We have also performed simulations in the liquid domain of the phase diagram. We found a free energy curve monotonically growing with the nucleus size, consistent with the liquid domain.

  5. An assessment of the isotopic (2H/18O) integrity of water samples collected and stored by unattended precipitation totalizers

    NASA Astrophysics Data System (ADS)

    Terzer, Stefan; Wassenaar, Leonard I.; Douence, Cedric; Araguas-Araguas, Luis

    2016-04-01

    The IAEA-WMO Global Network of Isotopes in Precipitation (GNIP) provides worldwide δ18O and δ2H data for numerous hydrological and climatological studies. The traditional GNIP sample collection method relies on weather station operators to accumulate precipitation obtained from manual rain gauges. Over the past decades, widespread weather station automatization resulted in the increased use of unattended precipitation totalizers that accumulate and store the rainwater in the field for up to one month. Several low-tech measures were adopted to prevent in situ secondary evaporative isotopic enrichment (SEE) of totalized water samples (i.e. disequilibrium isotopic fractionation after precipitation is stored in the collection device). These include: (a) adding a 0.5-1 cm floating layer of paraffin oil to the totalizer bottle, (b) using an intake tube leading from the collection funnel and submerged to the bottom of the totalizer bottle, or (c) placing a table tennis ball in the funnel aiming to reduce evaporation of the collected water from the receiving bottle to the atmosphere. We assessed the isotopic integrity of stored rainwater samples for three totalizers under controlled settings: each aforementioned totalizer was filled with a 100 or 500 mL of isotopically known water and installed in the field with the intake funnels sheltered to prevent rainwater collection. Potential evapotranspiration (PET) was obtained from on-site meteorological recordings. Stored evaporative loss from each totalizer was evaluated on a monthly basis; gravimetrically and by analysing δ18O and δ2H of the stored water, for a period of 6 months and a cumulative PET of ˜500 mm. The gravimetric and isotope results revealed that for smaller water volumes (100 ml, corresponding to ca. 5 mm of monthly precipitation), negligible isotope enrichment (δ18O) was observed in the paraffin-oil based totalizer, whereas unacceptable evaporative isotope effects were observed for the ball

  6. Seasonal associations and atmospheric transport distances of Fusarium collected with unmanned aerial vehicles and ground-based sampling devices

    NASA Astrophysics Data System (ADS)

    Schmale, David; Ross, Shane; Lin, Binbin

    2014-05-01

    Spores of fungi in the genus Fusarium may be transported through the atmosphere over long distances. Members of this genus are important pathogens and mycotoxin producers. New information is needed to characterize seasonal trends in atmospheric loads of Fusarium and to pinpoint the source(s) of inoculum at both local (farm) and regional (state or country) scales. Spores of Fusarium were collected from the atmosphere in an agricultural ecosystem in Blacksburg, VA, USA using a Burkard volumetric sampler (BVS) 1 m above ground level and autonomous unmanned aerial vehicles (UAVs) 100 m above ground level. More than 2,200 colony forming units (CFUs) of Fusarium were collected during 104 BVS sampling periods and 180 UAV sampling periods over four calendar years (2009-2012). Spore concentrations ranged from 0 to 13 and 0 to 23 spores m-3 for the BVS and the UAVs, respectively. Spore concentrations were generally higher in the fall, spring, and summer, and lower in the winter. Spore concentrations from the BVS were generally higher than those from the UAVs for both seasonal and hourly collections. Some of the species of Fusarium identified from our collections have not been previously reported in the state of Virginia. A Gaussian plume transport model was used to estimate distances to the potential inoculum source(s) by season. This work extends previous studies showing an association between atmospheric transport barriers (Lagrangian coherent structures or LCSs) and the movement of Fusarium in the lower atmosphere. An increased understanding of the aerobiology of Fusarium may contribute to new and improved control strategies for diseases causes by fusaria in the future.

  7. "Gateway hypothesis" and early drug use: Additional findings from tracking a population-based sample of adolescents to adulthood.

    PubMed

    Nkansah-Amankra, Stephen; Minelli, Mark

    2016-12-01

    To evaluate the consistency of the relationship between early drug use in adolescence and illegal drug use in adulthood as proposed in the "gateway theory" and to determine whether pre-existing depressive symptoms modifies this relationship. We used contractual data from the National Longitudinal Study of Adolescent to Adult health data spanning a 14 year period. We assessed the relationship between gateway drugs at baseline (age 11-20 years) and drug use in adulthood using generalized estimating equation (GEE) regression models. Gateways drugs used in early adolescence were significantly associated with marijuana use, illegal drugs and cocaine in older adolescence, but over time these relationships were not consistent in adulthood. Changes in the pattern of psychoactive drug use were important predictors of drug use in adulthood. A history of higher depressive symptoms was associated with higher frequencies of psychoactive drug use over time. Users of mental health services in adolescence were less likely to use drugs in older adolescence and in adulthood. Relationships between early drug use and later drug use in adulthood cannot be solely explained by the gateway hypothesis. Collectively, adolescent drug prevention and treatment programs should apply theory-based and evidence-proven multisectoral intervention strategies rather than providing a brief counseling on individual's behaviors. This evidence should include understanding that changes in behavior should involve broader analyses of the underlying social context for drug use and in particular the role of the community social norms in driving a group's behaviors.

  8. Vapor space characterization of waste Tank 241-BY-108: Results from samples collected on 10/27/94

    SciTech Connect

    McVeety, B.D.; Clauss, T.W.; Ligotke, M.W.

    1995-10-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-BY-108 (referred to as Tank BY-108). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water vapor (H{sub 2}O). Trends in NH{sub 3} and H{sub 2}O samples indicated a possible sampling problem. Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not requested. In addition, the authors looked for the 40 TO-14 compounds plus an additional 15 analytes. Of these, 17 were observed above the 5-ppbv reporting cutoff. Also, eighty-one organic tentatively identified compounds (TICs) were observed above the reporting cutoff (ca.) 10 ppbv, and are reported with concentrations that are semiquantitative estimates based on internal standard response factors. The nine organic analytes with the highest estimated concentrations are listed in Summary Table 1 and account for approximately 48% of the total organic components in the headspace of Tank BY-108. Three permanent gases, hydrogen (H{sub 2}), carbon dioxide (CO{sub 2}), and nitrous oxide (N{sub 2}O) were also detected. Tank BY-108 is on the Ferrocyanide Watch List.

  9. Analysis of Dust Samples Collected from an Unused Spent Nuclear Fuel Interim Storage Container at Hope Creek, Delaware.

    SciTech Connect

    Bryan, Charles R.; Enos, David

    2015-03-01

    In July, 2014, the Electric Power Research Institute and industry partners sampled dust on the surface of an unused canister that had been stored in an overpack at the Hope Creek Nuclear Generating Station for approximately one year. The foreign material exclusion (FME) cover that had been on the top of the canister during storage, and a second recently - removed FME cover, were also sampled. This report summarizes the results of analyses of dust samples collected from the unused Hope Creek canister and the FME covers. Both wet and dry samples of the dust/salts were collected, using SaltSmart(TM) sensors and Scotch - Brite(TM) abrasive pads, respectively. The SaltSmart(TM) samples were leached and the leachate analyzed chemically to determine the composition and surface load per unit area of soluble salts present on the canister surface. The dry pad samples were analyzed by X-ray fluorescence and by scanning electron microscopy to determine dust texture and mineralogy; and by leaching and chemical analysis to deter mine soluble salt compositions. The analyses showed that the dominant particles on the canister surface were stainless steel particles, generated during manufacturing of the canister. Sparse environmentally - derived silicates and aluminosilicates were also present. Salt phases were sparse, and consisted of mostly of sulfates with rare nitrates and chlorides. On the FME covers, the dusts were mostly silicates/aluminosilicates; the soluble salts were consistent with those on the canister surface, and were dominantly sulfates. It should be noted that the FME covers were w ashed by rain prior to sampling, which had an unknown effect of the measured salt loads and compositions. Sulfate salts dominated the assemblages on the canister and FME surfaces, and in cluded Ca - SO4 , but also Na - SO4 , K - SO4 , and Na - Al - SO4 . It is likely that these salts were formed by particle - gas conversion reactions, either

  10. COMPARISON OF RESULTS FOR QUARTER 3 SURFACE WATER SPLIT SAMPLES COLLECTED AT THE NUCLEAR FUEL SERVICES SITE, ERWIN, TENNESSEE

    SciTech Connect

    none,

    2013-05-28

    Oak Ridge Associated Universities (ORAU), under the Oak Ridge Institute for Science and Education (ORISE) contract, collected split surface water samples with Nuclear Fuel Services (NFS) representatives on March 20, 2013. Representatives from the U.S. Nuclear Regulatory Commission and the Tennessee Department of Environment and Conservation were also in attendance. Samples were collected at four surface water stations, as required in the approved Request for Technical Assistance number 11-018. These stations included Nolichucky River upstream (NRU), Nolichucky River downstream (NRD), Martin Creek upstream (MCU), and Martin Creek downstream (MCD). Both ORAU and NFS performed gross alpha and gross beta analyses, and Table 1 presents the comparison of results using the duplicate error ratio (DER), also known as the normalized absolute difference. A DER {<=} 3 indicates that at a 99% confidence interval, split sample results do not differ significantly when compared to their respective one standard deviation (sigma) uncertainty (ANSI N42.22). The NFS split sample report does not specify the confidence level of reported uncertainties (NFS 2013). Therefore, standard two sigma reporting is assumed and uncertainty values were divided by 1.96. In conclusion, most DER values were less than 3 and results are consistent with low (e.g., background) concentrations. The gross beta result for sample 5198W0012 was the exception. The ORAU result of 9.23 ± 0.73 pCi/L from location MCD is well above NFS's result of -0.567 ± 0.63 pCi/L (non-detected). NFS's data package included a detected result for U-233/234, but no other uranium or plutonium detection, and nothing that would suggest the presence of beta-emitting radionuclides. The ORAU laboratory reanalyzed sample 5198W0012 using the remaining portion of the sample volume and a result of 11.3 ± 1.1 pCi/L was determined. As directed, the laboratory also counted the filtrate using gamma spectrometry analysis and

  11. Waste tank vapor project: Vapor characterization of Tank 241-C-103: Data report for OVS samples collected from Sample Job 7b, Parts I and II, received 5/18/94 and 5/24/94

    SciTech Connect

    Clauss, T.R.; Edwards, J.A.; Fruchter, J.S.

    1994-09-01

    On 5/18/94, Westinghouse Hanford Company (WHC) delivered samples to Pacific Northwest Laboratory (PNL) that were collected from waste Tank 241-C-103 on 5/16/94. These samples were from Sample Job (SJ) 7b, Part 1. On 5/24/94, WHC delivered samples to PNL that were collected from waste Tank 241-C-103 on 5/18/94. These samples were from SJ7b, Part 2. A summary of data derived from the sampling of waste Tank 241-C-103 for gravimetric (H{sub 2}O) and normal paraffin hydrocarbon (NPH) concentrations are shown for SJ7b. Gravimetric analysis was performed on the samples within 24 hours of receipt by PNL. The NPH concentration of 10 samples collected for Part 1 was slightly higher than the average concentration for 15 samples collected in Part 2, 812 ({+-} 133) mg/m{sup 3} and 659 ({+-} 88) mg/m{sup 3}, respectively. The higher concentrations measured in Part 1 samples may be because the samples in Part 1 were collected at a single level, 0.79 meters above the air-liquid interface. Part 2 samples were collected at three different tank levels, 0.79, 2.92, and 5.05 m above the air-liquid interface. In Part 2, the average NPH concentrations for 5 samples collected at each of three levels was similar: 697 (60) mg/m{sup 3} at the low level, 631 (51) mg/m{sup 3} at the mid level, and 651 (134) mg/m{sup 3} at the high level. It is important to note that the measured tridecane to dodecane concentration remained constant in all samples collected in Parts 1 and 2. That ratio is 1.2 {+-} 0.05. This consistent ratio indicates that there were no random analytical biases towards either compound.

  12. Exposing USGS sample collections for broader discovery and access: collaboration between ScienceBase, IEDA:SESAR, and Paleobiology Database

    NASA Astrophysics Data System (ADS)

    Hsu, L.; Bristol, S.; Lehnert, K. A.; Arko, R. A.; Peters, S. E.; Uhen, M. D.; Song, L.

    2014-12-01

    The U.S. Geological Survey (USGS) is an exemplar of the need for improved cyberinfrastructure for its vast holdings of invaluable physical geoscience data. Millions of discrete paleobiological and geological specimens lie in USGS warehouses and at the Smithsonian Institution. These specimens serve as the basis for many geologic maps and geochemical databases, and are a potential treasure trove of new scientific knowledge. The extent of this treasure is virtually unknown and inaccessible outside a small group of paleogeoscientists and geochemists. A team from the USGS, the Integrated Earth Data Applications (IEDA) facility, and the Paleobiology Database (PBDB) are working to expose information on paleontological and geochemical specimens for discovery by scientists and citizens. This project uses existing infrastructure of the System for Earth Sample Registration (SESAR) and PBDB, which already contains much of the fundamental data schemas that are necessary to accommodate USGS records. The project is also developing a new Linked Data interface for the USGS National Geochemical Database (NGDB). The International Geo Sample Number (IGSN) is the identifier that links samples between all systems. For paleontological specimens, SESAR and PBDB will be the primary repositories for USGS records, with a data syncing process to archive records within the USGS ScienceBase system. The process began with mapping the metadata fields necessary for USGS collections to the existing SESAR and PBDB data structures, while aligning them with the Observations & Measurements and Darwin Core standards. New functionality needed in SESAR included links to a USGS locality registry, fossil classifications, a spatial qualifier attribution for samples with sensitive locations, and acknowledgement of data and metadata licensing. The team is developing a harvesting mechanism to periodically transfer USGS records from within PBDB and SESAR to ScienceBase. For the NGDB, the samples are being

  13. Collections of human biological samples for scientific purposes. Why do current regulation need to be clarified and how?

    PubMed

    Deplanque, Dominique; Birraux, Guillaume; Bertoye, Pierre-Henri; Postaire, Eric

    2009-01-01

    The collection of human biological samples is of major importance for future research in France and Europe. In recent years, new regulatory procedures have been designed to monitor these activities; but they are somewhat complex and some clarifications are needed. The law needs also to be amended. The definition of biobanking activities should be clarified, and regulatory procedures, including consultation of the Ethics Committee, declarations to the Ministry of Research and the protection of personal data, should be simplified. It is also of great importance to correctly define the modalities in which Biobanks are granted their authorisations. The role of Ethics Committees regarding the evaluation of information and the consent procedures should also be clarified, particularly when samples from children are used, or when the samples are used for genetic analyses. As well as scientific and public health aspects, the storage of human biological samples may also have important economic consequences. It is hence crucial to adapt the procedure for submitting patents, particularly when several public or private partners are working together. The possible changes to both French and European laws planned in the next months would be an ideal time to introduce these changes.

  14. Analysis of sequences from field samples reveals the presence of the recently described pepper vein yellows virus (genus Polerovirus) in six additional countries.

    PubMed

    Knierim, Dennis; Tsai, Wen-Shi; Kenyon, Lawrence

    2013-06-01

    Polerovirus infection was detected by reverse transcription polymerase chain reaction (RT-PCR) in 29 pepper plants (Capsicum spp.) and one black nightshade plant (Solanum nigrum) sample collected from fields in India, Indonesia, Mali, Philippines, Thailand and Taiwan. At least two representative samples for each country were selected to generate a general polerovirus RT-PCR product of 1.4 kb length for sequencing. Sequence analysis of the partial genome sequences revealed the presence of pepper vein yellows virus (PeVYV) in all 13 samples. A 1990 Australian herbarium sample of pepper described by serological means as infected with capsicum yellows virus (CYV) was identified by sequence analysis of a partial CP sequence as probably infected with a potato leaf roll virus (PLRV) isolate.

  15. Headspace vapor characterization of Hanford Waste Tank SX-102: Results from samples collected on July 19, 1995. Tank Vapor Characterization Project

    SciTech Connect

    McVeety, B.D.; Evans, J.C.; Clauss, T.W.; Pool, K.H.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-SX-102 (Tank SX-102) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed under the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5046. Samples were collected by WHC on July 19, 1995, using the vapor sampling system (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  16. Headspace vapor characterization of Hanford Waste Tank 241-T-110: Results from samples collected on August 31, 1995. Tank Vapor Characterization Project

    SciTech Connect

    McVeety, B.D.; Thomas, B.L.; Evans, J.C.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-T-110 (Tank T-110) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5056. Samples were collected by WHC on August 31, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  17. Headspace vapor characterization of Hanford Waste Tank AX-101: Results from samples collected on June 15, 1995. Tank Vapor Characterization Project

    SciTech Connect

    Pool, K.H.; Clauss, T.W.; Evans, J.C.; McVeety, B.D.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-AX-101 (Tank AX-101) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) under the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5028. Samples were collected by WHC on June 15, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  18. Headspace vapor characterization of Hanford Waste Tank 241-BX-107: Results from samples collected on November 17, 1995. Tank Vapor Characterization Project

    SciTech Connect

    Evans, J.C.; Thomas, B.L.; Pool, K.H.

    1996-06-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-BX-107 (Tank BX-107) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5080. Samples were collected by WHC on November 17, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  19. Headspace vapor characterization of Hanford Waste Tank 241-S-108: Results from samples collected on December 6, 1995. Tank Vapor Characterization Project

    SciTech Connect

    Thomas, B.L.; Evans, J.C.; McVeety, B.D.

    1996-06-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-S-108 (Tank S-108) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5086. Samples were collected by WHC on December 6, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  20. Headspace vapor characterization of Hanford Waste Tank 241-A-103: Results from samples collected on November 9, 1995. Tank Vapor Characterization Project

    SciTech Connect

    Evans, J.C.; Thomas, B.L.; Pool, K.H.; Olsen, K.B.

    1996-06-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-A-103 (Tank A-103) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5073. Samples were collected by WHC on November 9, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.