Sample records for adequate dose coverage

  1. Impact of using different four-dimensional computed tomography data sets to design proton treatment plans for distal esophageal cancer.

    PubMed

    Pan, Xiaoning; Zhang, Xiaodong; Li, Yupeng; Mohan, Radhe; Liao, Zhongxing

    2009-02-01

    To study the impact of selecting different data sets from four-dimensional computed tomography (4D CT) imaging during proton treatment planning in patients with distal esophageal cancer. We examined the effects of changes in 4D CT data set and smearing margins in proton treatment planning for 5 patients with distal esophageal cancer whose diaphragms were in the beam path and could move several centimeters during respiration. Planning strategies based on (1) average, (2) inspiration, and (3) expiration CT were evaluated in terms of their coverage on the internal clinic target volume (ICTV) at the prescribed dose. For Strategy 1, increasing the smearing margin caused an increase in the ICTV prescription dose coverage (PDC) at the end-exhalation phase for all patients, whereas the ICTV PDC decreased for some patients at the end-inhalation phase. For Strategy 2, a smearing margin in the range of 1.0 to 3.5 cm caused the ICTV PDC to remain essentially unchanged, regardless of which phase of 4D CT was used for dose calculation, for all patients. For Strategy 3, the ICTV coverage was adequate for 2 of the 5 patients when a smearing margin of less than 1.0 cm was used, but was not adequate for the other 3 patients regardless of the smearing margin. Using the inspiration CT plus a smearing margin can lead to adequate ICTV coverage in treatment plans for patients with distal esophageal tumors surrounded by tissue that is subject to large changes in density during a proton treatment.

  2. Vaccination Coverage Among Children Aged 2 Years - U.S. Affiliated Pacific Islands, April-October, 2016.

    PubMed

    Tippins, Ashley; Murthy, Neil; Meghani, Mehreen; Solsman, Amy; Apaisam, Carter; Basilius, Merlyn; Eckert, Maribeth; Judicpa, Peter; Masunu, Yolanda; Pistotnik, Kelsey; Pedro, Daisy; Sasamoto, Jeremy; Underwood, J Michael

    2018-05-25

    Vaccine-preventable diseases (VPDs) cause substantial morbidity and mortality in the United States Affiliated Pacific Islands (USAPI).* CDC collaborates with USAPI immunization programs to monitor vaccination coverage. In 2016, † USAPI immunization programs and CDC piloted a method for estimating up-to-date status among children aged 2 years using medical record abstraction to ascertain regional vaccination coverage. This was the first concurrent assessment of childhood vaccination coverage across five USAPI jurisdictions (American Samoa; Chuuk State, Federated States of Micronesia [FSM]; Commonwealth of the Northern Mariana Islands [CNMI]; Republic of the Marshall Islands [RMI]; and Republic of Palau). § Differences in vaccination coverage between main and outer islands ¶ were assessed for two jurisdictions where data were adequate.** Series coverage in this report includes the following doses of vaccines: ≥4 doses of diphtheria and tetanus toxoids and acellular pertussis vaccine (DTaP); ≥3 doses of inactivated poliovirus vaccine (IPV); ≥1 dose of measles, mumps, and rubella vaccine (MMR); ≥3 doses of Haemophilus influenzae type B (Hib) vaccine; ≥3 doses of hepatitis B (HepB) vaccine; and ≥4 doses of pneumococcal conjugate vaccine (PCV); i.e., 4:3:1:3:3:4. Coverage with ≥3 doses of rotavirus vaccine was also assessed. Completion of the recommended series of each of these vaccines †† was <90% in all jurisdictions except Palau. Coverage with the full recommended six-vaccine series (4:3:1:3:3:4) ranged from 19.5% (Chuuk) to 69.1% (Palau). In RMI and Chuuk, coverage was lower in the outer islands than in the main islands for most vaccines, with differences ranging from 0.9 to 66.8 percentage points. Medical record abstraction enabled rapid vaccination coverage assessment and timely dissemination of results to guide programmatic decision-making. Effectively monitoring vaccination coverage, coupled with implementation of data-driven interventions, is essential to maintain protection from VPD outbreaks in the region and the mainland United States.

  3. Impact of Using Different Four-Dimensional Computed Tomography Data Sets to Design Proton Treatment Plans for Distal Esophageal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pan Xiaoning; Zhang Xiaodong; Li Yupeng

    2009-02-01

    Purpose: To study the impact of selecting different data sets from four-dimensional computed tomography (4D CT) imaging during proton treatment planning in patients with distal esophageal cancer. Methods and Materials: We examined the effects of changes in 4D CT data set and smearing margins in proton treatment planning for 5 patients with distal esophageal cancer whose diaphragms were in the beam path and could move several centimeters during respiration. Planning strategies based on (1) average, (2) inspiration, and (3) expiration CT were evaluated in terms of their coverage on the internal clinic target volume (ICTV) at the prescribed dose. Results:more » For Strategy 1, increasing the smearing margin caused an increase in the ICTV prescription dose coverage (PDC) at the end-exhalation phase for all patients, whereas the ICTV PDC decreased for some patients at the end-inhalation phase. For Strategy 2, a smearing margin in the range of 1.0 to 3.5 cm caused the ICTV PDC to remain essentially unchanged, regardless of which phase of 4D CT was used for dose calculation, for all patients. For Strategy 3, the ICTV coverage was adequate for 2 of the 5 patients when a smearing margin of less than 1.0 cm was used, but was not adequate for the other 3 patients regardless of the smearing margin. Conclusion: Using the inspiration CT plus a smearing margin can lead to adequate ICTV coverage in treatment plans for patients with distal esophageal tumors surrounded by tissue that is subject to large changes in density during a proton treatment.« less

  4. Dosimetric comparison between VMAT with different dose calculation algorithms and protons for soft-tissue sarcoma radiotherapy.

    PubMed

    Fogliata, Antonella; Scorsetti, Marta; Navarria, Piera; Catalano, Maddalena; Clivio, Alessandro; Cozzi, Luca; Lobefalo, Francesca; Nicolini, Giorgia; Palumbo, Valentina; Pellegrini, Chiara; Reggiori, Giacomo; Roggio, Antonella; Vanetti, Eugenio; Alongi, Filippo; Pentimalli, Sara; Mancosu, Pietro

    2013-04-01

    To appraise the potential of volumetric modulated arc therapy (VMAT, RapidArc) and proton beams to simultaneously achieve target coverage and enhanced sparing of bone tissue in the treatment of soft-tissue sarcoma with adequate target coverage. Ten patients presenting with soft-tissue sarcoma of the leg were collected for the study. Dose was prescribed to 66.5 Gy in 25 fractions to the planning target volume (PTV) while significant maximum dose to the bone was constrained to 50 Gy. Plans were optimised according to the RapidArc technique with 6 MV photon beams or for intensity modulated protons. RapidArc photon plans were computed with: 1) AAA; 2) Acuros XB as dose to medium; and 3) Acuros XB as dose to water. All plans acceptably met the criteria of target coverage (V95% >90-95%) and bone sparing (D(1 cm3) <50 Gy). Significantly higher PTV dose homogeneity was found for proton plans. Near-to-maximum dose to bone was similar for RapidArc and protons, while volume receiving medium/low dose levels was minimised with protons. Similar results were obtained for the remaining normal tissue. Dose distributions calculated with the dose to water option resulted ~5% higher than corresponding ones computed as dose to medium. High plan quality was demonstrated for both VMAT and proton techniques when applied to soft-tissue sarcoma.

  5. Sensitivity of postplanning target and OAR coverage estimates to dosimetric margin distribution sampling parameters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu Huijun; Gordon, J. James; Siebers, Jeffrey V.

    2011-02-15

    Purpose: A dosimetric margin (DM) is the margin in a specified direction between a structure and a specified isodose surface, corresponding to a prescription or tolerance dose. The dosimetric margin distribution (DMD) is the distribution of DMs over all directions. Given a geometric uncertainty model, representing inter- or intrafraction setup uncertainties or internal organ motion, the DMD can be used to calculate coverage Q, which is the probability that a realized target or organ-at-risk (OAR) dose metric D{sub v} exceeds the corresponding prescription or tolerance dose. Postplanning coverage evaluation quantifies the percentage of uncertainties for which target and OAR structuresmore » meet their intended dose constraints. The goal of the present work is to evaluate coverage probabilities for 28 prostate treatment plans to determine DMD sampling parameters that ensure adequate accuracy for postplanning coverage estimates. Methods: Normally distributed interfraction setup uncertainties were applied to 28 plans for localized prostate cancer, with prescribed dose of 79.2 Gy and 10 mm clinical target volume to planning target volume (CTV-to-PTV) margins. Using angular or isotropic sampling techniques, dosimetric margins were determined for the CTV, bladder and rectum, assuming shift invariance of the dose distribution. For angular sampling, DMDs were sampled at fixed angular intervals {omega} (e.g., {omega}=1 deg., 2 deg., 5 deg., 10 deg., 20 deg.). Isotropic samples were uniformly distributed on the unit sphere resulting in variable angular increments, but were calculated for the same number of sampling directions as angular DMDs, and accordingly characterized by the effective angular increment {omega}{sub eff}. In each direction, the DM was calculated by moving the structure in radial steps of size {delta}(=0.1,0.2,0.5,1 mm) until the specified isodose was crossed. Coverage estimation accuracy {Delta}Q was quantified as a function of the sampling parameters {omega} or {omega}{sub eff} and {delta}. Results: The accuracy of coverage estimates depends on angular and radial DMD sampling parameters {omega} or {omega}{sub eff} and {delta}, as well as the employed sampling technique. Target |{Delta}Q|<1% and OAR |{Delta}Q|<3% can be achieved with sampling parameters {omega} or {omega}{sub eff}=20 deg., {delta}=1 mm. Better accuracy (target |{Delta}Q|<0.5% and OAR |{Delta}Q|<{approx}1%) can be achieved with {omega} or {omega}{sub eff}=10 deg., {delta}=0.5 mm. As the number of sampling points decreases, the isotropic sampling method maintains better accuracy than fixed angular sampling. Conclusions: Coverage estimates for post-planning evaluation are essential since coverage values of targets and OARs often differ from the values implied by the static margin-based plans. Finer sampling of the DMD enables more accurate assessment of the effect of geometric uncertainties on coverage estimates prior to treatment. DMD sampling with {omega} or {omega}{sub eff}=10 deg. and {delta}=0.5 mm should be adequate for planning purposes.« less

  6. Sensitivity of postplanning target and OAR coverage estimates to dosimetric margin distribution sampling parameters.

    PubMed

    Xu, Huijun; Gordon, J James; Siebers, Jeffrey V

    2011-02-01

    A dosimetric margin (DM) is the margin in a specified direction between a structure and a specified isodose surface, corresponding to a prescription or tolerance dose. The dosimetric margin distribution (DMD) is the distribution of DMs over all directions. Given a geometric uncertainty model, representing inter- or intrafraction setup uncertainties or internal organ motion, the DMD can be used to calculate coverage Q, which is the probability that a realized target or organ-at-risk (OAR) dose metric D, exceeds the corresponding prescription or tolerance dose. Postplanning coverage evaluation quantifies the percentage of uncertainties for which target and OAR structures meet their intended dose constraints. The goal of the present work is to evaluate coverage probabilities for 28 prostate treatment plans to determine DMD sampling parameters that ensure adequate accuracy for postplanning coverage estimates. Normally distributed interfraction setup uncertainties were applied to 28 plans for localized prostate cancer, with prescribed dose of 79.2 Gy and 10 mm clinical target volume to planning target volume (CTV-to-PTV) margins. Using angular or isotropic sampling techniques, dosimetric margins were determined for the CTV, bladder and rectum, assuming shift invariance of the dose distribution. For angular sampling, DMDs were sampled at fixed angular intervals w (e.g., w = 1 degree, 2 degrees, 5 degrees, 10 degrees, 20 degrees). Isotropic samples were uniformly distributed on the unit sphere resulting in variable angular increments, but were calculated for the same number of sampling directions as angular DMDs, and accordingly characterized by the effective angular increment omega eff. In each direction, the DM was calculated by moving the structure in radial steps of size delta (=0.1, 0.2, 0.5, 1 mm) until the specified isodose was crossed. Coverage estimation accuracy deltaQ was quantified as a function of the sampling parameters omega or omega eff and delta. The accuracy of coverage estimates depends on angular and radial DMD sampling parameters omega or omega eff and delta, as well as the employed sampling technique. Target deltaQ/ < l% and OAR /deltaQ/ < 3% can be achieved with sampling parameters omega or omega eef = 20 degrees, delta =1 mm. Better accuracy (target /deltaQ < 0.5% and OAR /deltaQ < approximately 1%) can be achieved with omega or omega eff = 10 degrees, delta = 0.5 mm. As the number of sampling points decreases, the isotropic sampling method maintains better accuracy than fixed angular sampling. Coverage estimates for post-planning evaluation are essential since coverage values of targets and OARs often differ from the values implied by the static margin-based plans. Finer sampling of the DMD enables more accurate assessment of the effect of geometric uncertainties on coverage estimates prior to treatment. DMD sampling with omega or omega eff = 10 degrees and delta = 0.5 mm should be adequate for planning purposes.

  7. Human papillomavirus vaccination coverage among females and males, National Health and Nutrition Examination Survey, United States, 2007-2016.

    PubMed

    Lewis, Rayleen M; Markowitz, Lauri E

    2018-05-03

    Human papillomavirus (HPV) vaccination has been routinely recommended at age 11-12 years in the United States for females since 2006 and males since 2011. Coverage can be estimated using self/parent-reported HPV vaccination collected in the National Health and Nutrition Examination Survey (NHANES) for a wider age range than other national surveys. We assessed vaccination coverage in 2015-2016, temporal trends by age, and the validity of self/parent-reported vaccination status. Participants aged 9-59 years completed an interview collecting demographic and vaccination information. Weighted coverage was estimated for two-year NHANES cycles by age group for 2007-2008 to 2015-2016 for females (N = 14318) and 2011-2012 to 2015-2016 for males (N = 7847). Temporal trends in coverage were assessed from 2007-2008 to 2011-2012 for females and from 2011-2012 to 2015-2016 for both sexes. Sensitivity and specificity of self/parent-reported vaccination were assessed using provider-verified vaccination records from a pilot study in 14-29 year-olds. In 2015-2016, ≥1 dose coverage among females was highest in 14-19 (54.7%) and 20-24 (56.0%) year-olds and lower in successively older age groups. Among males, ≥1 dose coverage was highest in 14-19 year-olds (39.5%) and lower at older ages. Coverage was similar in 9-13 year-old females and males. Between 2007-2008 and 2011-2012, there were increases among females younger than 30 years. Between 2011-2012 and 2015-2016, there were increases among female age groups including 20-39 year-olds; male coverage increased among ages 9-13, 14-19, and 20-24 years. Self/parent-reported receipt of ≥1 dose had a sensitivity and specificity of 87.0% and 83.3%. Performance was lower for 3 doses. While overall HPV vaccination coverage remains low, it is higher in females than males, except in 9-13 year-olds. There have been increases in coverage among many age groups, but coverage has stalled in younger females. Adequate validity was demonstrated for self/parent-reported vaccination of ≥1 dose, but not 3 doses, in a pilot study. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Combined photon-electron beams in the treatment of the supraclavicular lymph nodes in breast cancer: A novel technique that achieves adequate coverage while reducing lung dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salem, Ahmed, E-mail: ahmed.salem@doctors.org.uk; Mohamad, Issa; Dayyat, Abdulmajeed

    2015-10-01

    Radiation pneumonitis is a well-documented side effect of radiation therapy for breast cancer. The purpose of this study was to compare combined photon-electron, photon-only, and electron-only plans in the radiation treatment of the supraclavicular lymph nodes. In total, 13 patients requiring chest wall and supraclavicular nodal irradiation were planned retrospectively using combined photon-electron, photon-only, and electron-only supraclavicular beams. A dose of 50 Gy over 25 fractions was prescribed. Chest wall irradiation parameters were fixed for all plans. The goal of this planning effort was to cover 95% of the supraclavicular clinical target volume (CTV) with 95% of the prescribed dosemore » and to minimize the volume receiving ≥ 105% of the dose. Comparative end points were supraclavicular CTV coverage (volume covered by the 95% isodose line), hotspot volume, maximum radiation dose, contralateral breast dose, mean total lung dose, total lung volume percentage receiving at least 20 Gy (V{sub 20} {sub Gy}), heart volume percentage receiving at least 25 Gy (V{sub 25} {sub Gy}). Electron and photon energies ranged from 8 to 18 MeV and 4 to 6 MV, respectively. The ratio of photon-to-electron fractions in combined beams ranged from 5:20 to 15:10. Supraclavicular nodal coverage was highest in photon-only (mean = 96.2 ± 3.5%) followed closely by combined photon-electron (mean = 94.2 ± 2.5%) and lowest in electron-only plans (mean = 81.7 ± 14.8%, p < 0.001). The volume of tissue receiving ≥ 105% of the prescription dose was higher in the electron-only (mean = 69.7 ± 56.1 cm{sup 3}) as opposed to combined photon-electron (mean = 50.8 ± 40.9 cm{sup 3}) and photon-only beams (mean = 32.2 ± 28.1 cm{sup 3}, p = 0.114). Heart V{sub 25} {sub Gy} was not statistically different among the plans (p = 0.999). Total lung V{sub 20} {sub Gy} was lowest in electron-only (mean = 10.9 ± 2.3%) followed by combined photon-electron (mean = 13.8 ± 2.3%) and highest in photon-only plans (mean = 16.2 ± 3%, p < 0.001). As expected, photon-only plans demonstrated the highest target coverage and total lung V{sub 20} {sub Gy}. The superiority of electron-only beams, in terms of decreasing lung dose, is set back by the dosimetric hotspots associated with such plans. Combined photon-electron treatment is a feasible technique for supraclavicular nodal irradiation and results in adequate target coverage, acceptable dosimetric hotspot volume, and slightly reduced lung dose.« less

  9. Properties of model-averaged BMDLs: a study of model averaging in dichotomous response risk estimation.

    PubMed

    Wheeler, Matthew W; Bailer, A John

    2007-06-01

    Model averaging (MA) has been proposed as a method of accounting for model uncertainty in benchmark dose (BMD) estimation. The technique has been used to average BMD dose estimates derived from dichotomous dose-response experiments, microbial dose-response experiments, as well as observational epidemiological studies. While MA is a promising tool for the risk assessor, a previous study suggested that the simple strategy of averaging individual models' BMD lower limits did not yield interval estimators that met nominal coverage levels in certain situations, and this performance was very sensitive to the underlying model space chosen. We present a different, more computationally intensive, approach in which the BMD is estimated using the average dose-response model and the corresponding benchmark dose lower bound (BMDL) is computed by bootstrapping. This method is illustrated with TiO(2) dose-response rat lung cancer data, and then systematically studied through an extensive Monte Carlo simulation. The results of this study suggest that the MA-BMD, estimated using this technique, performs better, in terms of bias and coverage, than the previous MA methodology. Further, the MA-BMDL achieves nominal coverage in most cases, and is superior to picking the "best fitting model" when estimating the benchmark dose. Although these results show utility of MA for benchmark dose risk estimation, they continue to highlight the importance of choosing an adequate model space as well as proper model fit diagnostics.

  10. TU-H-CAMPUS-JeP2-04: Deriving Delivered Doses to Assess the Viability of 2.5 Mm Margins in Head and Neck SBRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, S; Shang, Q; Godley, A

    Purpose: To calculate the delivered dose for head and neck SBRT patients using pre-treatment images. This delivered dose was then used to determine the viability of 2.5 mm margins. Methods: Daily cone beam CTs (CBCTs) were collected for 20 patients along with a planning CT, planned dose, and planning structures. The day 1 CBCT was aligned to the planning CT using the treatment shifts (six degrees of freedom) and then the dose and contours were transferred to the CBCT. The day 1 CBCT becomes the reference image for days 2–5. The day 2–5 CBCTs were also aligned to the planningmore » CT using the treatment shifts given and the dose transferred. The day 2–5 CBCTs were then deformably registered to the day 1 CBCT. The doses delivered on days 2–5 were then deformed to the day 1 CBCT where they could be accumulated. This was achieved with MIM 6.5.1 (MIM Software, Cleveland OH). The accumulated doses for the 20 patients were evaluated against the planned doses using the initial planning criteria as points of comparison. Results: The delivered CTV dose conformed to the planned 98.6% coverage, with an average decrease of 2.6% between planned and delivered coverage. This implies the 2.5 mm margin was sufficient. Larger CTVs correlated to smaller differences between planned and delivered coverage. Delivered dose to critical structures including the spinal cord, mandible, brain, brainstem, and larynx was acceptable, with differences between planned and delivered max dose <5% on average. Similarly for the parotid glands, globes, cochlear, optic nerve, lens, and submandibular glands, differences between planned and delivered doses were generally <5%. Conclusion: The 2.5 mm margin provided acceptable CTV coverage, adequately accounting for setup errors. Organ at risk sparing was also satisfactory. Small tumor volumes (<20 cc) may require a larger margin to treat effectively.« less

  11. SU-F-T-35: Optimization of Bladder and Rectal Doses Using a Multi-Lumen Intracavitary Applicator for Gynecological Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laoui, S; Dietrich, S; Sehgal, V

    2016-06-15

    Purpose: Radiation dose delivery for endometrial cancer using HDR techniques is limited by dose to bladder and rectum. A dosimetric study was performed using Varian Capri vaginal brachytherapy applicator to determine the optimal channel configuration which minimizes dose to bladder and rectum, while providing good target coverage. Methods: A total of 17 patients, 63 plans clinically delivered, and 252 simulated plans using Varian BrachyVision planning system were generated to investigate optimal channel configuration which results in minimum dose to bladder and rectum while providing adequate target coverage. The Capri applicator consists of 13 lumens arranged in two concentric rings, onemore » central lumen and six lumens per ring. Manual dose shaping is invariably required to lower the dose to critical organs. Three-dimensional plans were simulated for 4 channel arrangements, all 13 channels, channel 12 o’clock (close to bladder) and 6 o’clock (close to rectum) deactivated, central channel deactivated, and central channel in addition to 12 o’clock and 6 o’clock deactivated. A relationship between V100, the volume that receives the prescribed dose, and the amount of curie-seconds required to deliver it, was established. Results: Using all 13 channels results in maximum dose to bladder and rectum. Deactivating central channel in addition to 12 o’clock and 6 o’clock resulted in minimizing bladder and rectum doses but compromised target coverage. The relationship between V100, the volume that receives the prescribed dose, and the curie seconds was found to be linear. Conclusion: Deactivating channels 12 o’clock and 6 o’clock was shown to be the optimal configuration leading to minimum dose to bladder and rectum without compromising target coverage. The linear relationship between V100 and the curie- seconds can be used as a verification parameter.« less

  12. Factors influencing utilization of intermittent preventive treatment for pregnancy in the Gushegu district, Ghana, 2013.

    PubMed

    Stephen, Atasige Awin-Irigu; Wurapa, Frederick; Afari, Edwin Andrew; Sackey, Samuel Oko; Malm, Keaziah Laurencia; Nyarko, Kofi Mensah

    2016-01-01

    The coverage of adequate (≥2 doses) IPTp-SP in Ghana is below the national target of 80% and that is a threat to reducing the incidence of malaria in pregnancy. The primary objective of the study was to determine the client and facility related factors associated with adequate uptake of IPTp-SP and suggest approaches for increased uptake. A cross sectional study was conducted among ANC clients and staff in Gushegu, questionnaires was administered to 330 conveniently sampled nursing mothers and all ANC staff present. A checklist and observation were used to collect health facility data. Data was analyzed descriptively and associations between the related factors and adequate uptake of IPTp-SP were determined. A total of 91.5% and 8.5% of respondents took adequate (≥2doses) and inadequate (≤1dose) IPTp-SP respectively. 85.4% respondents were early first ANC attendance and 80% were multiple gravidae. Mean ANC visits was 5.0 (standard deviation = 2.2). The key determinants for inadequate uptake of IPTp were Unemployment [OR= 4.9 95% CI (1.9-13.1], single gravidae [OR= 3.4 95% CI (1.5-7.6)] and late first ANC visit [OR= 6.8 95% CI (3.0-15.4)]. DOT practice, good staff attitude and health talk at the facility were observed and confirmed by ANC clients as satisfactory. adequate uptake of SP among respondents was high. Majorities were unemployed, have had multiple pregnancies and made early first ANC visits. Unemployment and late first ANC visits are significantly associated with taking inadequate SP dose. Adequate uptake of SP among respondents was high. Majorities were unemployed, have had multiple pregnancies and made early first ANC visits. Unemployment and late first ANC visits are significantly associated with taking inadequate SP dose.

  13. Coverage-based constraints for IMRT optimization

    NASA Astrophysics Data System (ADS)

    Mescher, H.; Ulrich, S.; Bangert, M.

    2017-09-01

    Radiation therapy treatment planning requires an incorporation of uncertainties in order to guarantee an adequate irradiation of the tumor volumes. In current clinical practice, uncertainties are accounted for implicitly with an expansion of the target volume according to generic margin recipes. Alternatively, it is possible to account for uncertainties by explicit minimization of objectives that describe worst-case treatment scenarios, the expectation value of the treatment or the coverage probability of the target volumes during treatment planning. In this note we show that approaches relying on objectives to induce a specific coverage of the clinical target volumes are inevitably sensitive to variation of the relative weighting of the objectives. To address this issue, we introduce coverage-based constraints for intensity-modulated radiation therapy (IMRT) treatment planning. Our implementation follows the concept of coverage-optimized planning that considers explicit error scenarios to calculate and optimize patient-specific probabilities q(\\hat{d}, \\hat{v}) of covering a specific target volume fraction \\hat{v} with a certain dose \\hat{d} . Using a constraint-based reformulation of coverage-based objectives we eliminate the trade-off between coverage and competing objectives during treatment planning. In-depth convergence tests including 324 treatment plan optimizations demonstrate the reliability of coverage-based constraints for varying levels of probability, dose and volume. General clinical applicability of coverage-based constraints is demonstrated for two cases. A sensitivity analysis regarding penalty variations within this planing study based on IMRT treatment planning using (1) coverage-based constraints, (2) coverage-based objectives, (3) probabilistic optimization, (4) robust optimization and (5) conventional margins illustrates the potential benefit of coverage-based constraints that do not require tedious adjustment of target volume objectives.

  14. Timely measles vaccination in Tianjin, China: a cross-sectional study of immunization records and mothers.

    PubMed

    Wagner, Abram L; Zhang, Ying; Montgomery, JoLynn P; Ding, Yaxing; Carlson, Bradley F; Boulton, Matthew L

    2014-08-29

    Measles is a highly infectious disease, and timely administration of two doses of vaccine can ensure adequate protection against measles for all ages in a population. This study aims to estimate the proportion of children aged 8 months to 6 years vaccinated on time with measles-containing vaccines (MCV) and vaccinated during the 2008 and 2010 measles supplementary immunization activities. This study also characterizes differences in mean age at vaccination and vaccination timeliness by demographic characteristics, and describes maternal knowledge of measles vaccination. Immunization records were selected from a convenience sample of immunization clinics in Tianjin, China. From the records, overall vaccination coverage and timely vaccination coverage were calculated for different demographic groups. Mothers were also interviewed at these clinics to ascertain their knowledge of measles vaccination. Within the 329 immunization clinic records, child's birth year and district of residence were found to be significant predictors of different measures of vaccine timeliness. Children born in 2009 had a lower age at MCV dose 2 administration (17.96 months) than children born in 2005 (22.00 months). Children living in Hebei, a district in the urban center of Tianjin were less likely to be vaccinated late than children living in districts further from the urban core of Tianjin. From the 31 interviews with mothers, most women believed that timely vaccination was very important and more than one dose was very necessary; most did not know whether their child needed another dose. When reviewing MCV coverage in China, most studies do not consider timeliness. However, this study shows that overall vaccination coverage can greatly overestimate vaccination coverage within certain segments of the population, such as young infants.

  15. Volumetric modulated arc therapy vs. IMRT for the treatment of distal esophageal cancer.

    PubMed

    Van Benthuysen, Liam; Hales, Lee; Podgorsak, Matthew B

    2011-01-01

    Several studies have demonstrated that volumetric modulated arc therapy (VMAT) has the ability to reduce monitor units and treatment time when compared with intensity-modulated radiation therapy (IMRT). This study aims to demonstrate that VMAT is able to provide adequate organs at risk (OAR) sparing and planning target volume (PTV) coverage for adenocarcinoma of the distal esophagus while reducing monitor units and treatment time. Fourteen patients having been treated previously for esophageal cancer were planned using both VMAT and IMRT techniques. Dosimetric quality was evaluated based on doses to several OARs, as well as coverage of the PTV. Treatment times were assessed by recording the number of monitor units required for dose delivery. Body V(5) was also recorded to evaluate the increased volume of healthy tissue irradiated to low doses. Dosimetric differences in OAR sparing between VMAT and IMRT were comparable. PTV coverage was similar for the 2 techniques but it was found that IMRT was capable of delivering a slightly more homogenous dose distribution. Of the 14 patients, 12 were treated with a single arc and 2 were treated with a double arc. Single-arc plans reduced monitor units by 42% when compared with the IMRT plans. Double-arc plans reduced monitor units by 67% when compared with IMRT. The V(5) for the body was found to be 18% greater for VMAT than for IMRT. VMAT has the capability to decrease treatment times over IMRT while still providing similar OAR sparing and PTV coverage. Although there will be a smaller risk of patient movement during VMAT treatments, this advantage comes at the cost of delivering small doses to a greater volume of the patient. Copyright © 2011 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  16. Factors influencing utilization of intermittent preventive treatment for pregnancy in the Gushegu district, Ghana, 2013

    PubMed Central

    Stephen, Atasige Awin-irigu; Wurapa, Frederick; Afari, Edwin Andrew; Sackey, Samuel Oko; Malm, Keaziah Laurencia; Nyarko, Kofi Mensah

    2016-01-01

    Introduction The coverage of adequate (≥2 doses) IPTp-SP in Ghana is below the national target of 80% and that is a threat to reducing the incidence of malaria in pregnancy. The primary objective of the study was to determine the client and facility related factors associated with adequate uptake of IPTp-SP and suggest approaches for increased uptake. Methods A cross sectional study was conducted among ANC clients and staff in Gushegu, questionnaires was administered to 330 conveniently sampled nursing mothers and all ANC staff present. A checklist and observation were used to collect health facility data. Data was analyzed descriptively and associations between the related factors and adequate uptake of IPTp-SP were determined. Results A total of 91.5% and 8.5% of respondents took adequate (≥2doses) and inadequate (≤1dose) IPTp-SP respectively. 85.4% respondents were early first ANC attendance and 80% were multiple gravidae. Mean ANC visits was 5.0 (standard deviation = 2.2). The key determinants for inadequate uptake of IPTp were Unemployment [OR= 4.9 95% CI (1.9-13.1], single gravidae [OR= 3.4 95% CI (1.5-7.6)] and late first ANC visit [OR= 6.8 95% CI (3.0-15.4)]. DOT practice, good staff attitude and health talk at the facility were observed and confirmed by ANC clients as satisfactory. adequate uptake of SP among respondents was high. Majorities were unemployed, have had multiple pregnancies and made early first ANC visits. Unemployment and late first ANC visits are significantly associated with taking inadequate SP dose. Conclusion Adequate uptake of SP among respondents was high. Majorities were unemployed, have had multiple pregnancies and made early first ANC visits. Unemployment and late first ANC visits are significantly associated with taking inadequate SP dose. PMID:28149434

  17. Sci—Thur PM: Planning and Delivery — 04: Respiratory margin derivation and verification in partial breast irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quirk, S; Conroy, L; Smith, WL

    Partial breast irradiation (PBI) following breast-conserving surgery is emerging as an effective means to achieve local control and reduce irradiated breast volume. Patients are planned on a static CT image; however, treatment is delivered while the patient is free-breathing. Respiratory motion can degrade plan quality by reducing target coverage and/or dose homogeneity. A variety of methods can be used to determine the required margin for respiratory motion in PBI. We derive geometric and dosimetric respiratory 1D margin. We also verify the adequacy of the typical 5 mm respiratory margin in 3D by evaluating plan quality for increasing respiratory amplitudes (2–20more » mm). Ten PBI plans were used for dosimetric evaluation. A database of volunteer respiratory data, with similar characteristics to breast cancer patients, was used for this study. We derived a geometric 95%-margin of 3 mm from the population respiratory data. We derived a dosimetric 95%-margin of 2 mm by convolving 1D dose profiles with respiratory probability density functions. The 5 mm respiratory margin is possibly too large when 1D coverage is assessed and could lead to unnecessary normal tissue irradiation. Assessing margins only for coverage may be insufficient; 3D dosimetric assessment revealed degradation in dose homogeneity is the limiting factor, not target coverage. Hotspots increased even for the smallest respiratory amplitudes, while target coverage only degraded at amplitudes greater than 10 mm. The 5 mm respiratory margin is adequate for coverage, but due to plan quality degradation, respiratory management is recommended for patients with respiratory amplitudes greater than 10 mm.« less

  18. Posology of insulins: A review of standard textbooks and product inserts.

    PubMed

    Bhutani, Garima; Kalra, Sanjay

    2015-01-01

    The study is aimed to assess whether the information contained in standard pharmacology, endocrinology, and diabetology textbooks regarding timings of administration, frequency and dose of various insulins is adequate and also to see whether the information contained in these texts is concordant with product inserts. Four standard textbooks of pharmacology, two of diabetology and three of endocrinology were assessed for the published information regarding dose, timing, and frequency of insulin administration. The product inserts of commonly available insulins in India were also studied for the same. Various omissions and disparities could be seen in the coverage of insulins in standard textbooks. Posology information about premixed insulins and basal insulins have been omitted by the majority of the textbooks. Details about dose, frequency and timings of ultra-short acting insulins have also not been covered by all textbooks. Some discrepancies regarding prescribing information was also noted in product inserts, especially in case of newer insulins. Thus, this article stresses upon the need of a uniform source of information for providing adequate and standardized knowledge regarding timing, frequency, and dose of insulins.

  19. Susceptibility to measles in migrant population: implication for policy makers.

    PubMed

    Ceccarelli, Giancarlo; Vita, Serena; Riva, Elisabetta; Cella, Eleonora; Lopalco, Maurizio; Antonelli, Francesca; De Cesaris, Marina; Fogolari, Marta; Dicuonzo, Giordano; Ciccozzi, Massimo; Angeletti, Silvia

    2018-01-01

    Despite a large measles outbreak is taking place in WHO European region, currently no data are available on measles immunization coverage in the asylum seeker and migrants hosted in this area. Two hundred and fifty-six migrants upon their arrival in Italy on March, April and May 2016 were screened for measles virus IgG antibodies by chemiluminescence immunoassay (Liaison XL analyzer, Diasorin, Italy). The virus susceptibility in this cohort, the differences between the official country reported and the observed measles immunization coverage and the impact of current measles outbreak on the asylum seekers hosted in the largest Asylum Seeker centres of Italy, were evaluated. The prevalence of subjects with positive result for measles IgG antibodies ranged between 79.9% and 100%. In Senegal, Mali, Nigeria, Pakistan and Bangladesh, the measles IgG seroprevalence observed was greater than the vaccinal coverage reported by WHO after I dose of vaccine. Based on data regarding the II dose coverage, the ASs population presented a seroprevalence greater to that expected. On the basis of the results obtained, extraordinary screening and vaccination campaigns in the migrant population, especially in the course of large outbreaks, could represent a resource to reach an adequate measles immunization coverage and to control this infectious disease. © International Society of Travel Medicine, 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  20. Whole Brain Irradiation With Hippocampal Sparing and Dose Escalation on Multiple Brain Metastases: A Planning Study on Treatment Concepts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prokic, Vesna, E-mail: vesna.prokic@uniklinik-freiburg.de; Wiedenmann, Nicole; Fels, Franziska

    2013-01-01

    Purpose: To develop a new treatment planning strategy in patients with multiple brain metastases. The goal was to perform whole brain irradiation (WBI) with hippocampal sparing and dose escalation on multiple brain metastases. Two treatment concepts were investigated: simultaneously integrated boost (SIB) and WBI followed by stereotactic fractionated radiation therapy sequential concept (SC). Methods and Materials: Treatment plans for both concepts were calculated for 10 patients with 2-8 brain metastases using volumetric modulated arc therapy. In the SIB concept, the prescribed dose was 30 Gy in 12 fractions to the whole brain and 51 Gy in 12 fractions to individualmore » brain metastases. In the SC concept, the prescription was 30 Gy in 12 fractions to the whole brain followed by 18 Gy in 2 fractions to brain metastases. All plans were optimized for dose coverage of whole brain and lesions, simultaneously minimizing dose to the hippocampus. The treatment plans were evaluated on target coverage, homogeneity, and minimal dose to the hippocampus and organs at risk. Results: The SIB concept enabled more successful sparing of the hippocampus; the mean dose to the hippocampus was 7.55 {+-} 0.62 Gy and 6.29 {+-} 0.62 Gy, respectively, when 5-mm and 10-mm avoidance regions around the hippocampus were used, normalized to 2-Gy fractions. In the SC concept, the mean dose to hippocampus was 9.8 {+-} 1.75 Gy. The mean dose to the whole brain (excluding metastases) was 33.2 {+-} 0.7 Gy and 32.7 {+-} 0.96 Gy, respectively, in the SIB concept, for 5-mm and 10-mm hippocampus avoidance regions, and 37.23 {+-} 1.42 Gy in SC. Conclusions: Both concepts, SIB and SC, were able to achieve adequate whole brain coverage and radiosurgery-equivalent dose distributions to individual brain metastases. The SIB technique achieved better sparing of the hippocampus, especially when a10-mm hippocampal avoidance region was used.« less

  1. Breast conserving treatment for breast cancer: dosimetric comparison of different non-invasive techniques for additional boost delivery

    PubMed Central

    2014-01-01

    Background Today it is unclear which technique for delivery of an additional boost after whole breast radiotherapy for breast conserved patients should be state of the art. We present a dosimetric comparison of different non-invasive treatment techniques for additional boost delivery. Methods For 10 different tumor bed localizations, 7 different non-invasive treatment plans were made. Dosimetric comparison of PTV-coverage and dose to organs at risk was performed. Results The Vero system achieved an excellent PTV-coverage and at the same time could minimize the dose to the organs at risk with an average near-maximum-dose (D2) to the heart of 0.9 Gy and the average volume of ipsilateral lung receiving 5 Gy (V5) of 1.5%. The TomoTherapy modalities delivered an average D2 to the heart of 0.9 Gy for the rotational and of 2.3 Gy for the static modality and an average V5 to the ipsilateral lung of 7.3% and 2.9% respectively. A rotational technique offers an adequate conformity at the cost of more low dose spread and a larger build-up area. In most cases a 2-field technique showed acceptable PTV-coverage, but a bad conformity. Electrons often delivered a worse PTV-coverage than photons, with the planning requirements achieved only in 2 patients and with an average D2 to the heart of 2.8 Gy and an average V5 to the ipsilateral lung of 5.8%. Conclusions We present advices which can be used as guidelines for the selection of the best individualized treatment. PMID:24467916

  2. An optimized posterior axillary boost technique in radiation therapy to supraclavicular and axillary lymph nodes: A comparative study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hernandez, Victor, E-mail: vhernandezmasgrau@gmail.com; Arenas, Meritxell; Müller, Katrin

    2013-01-01

    To assess the advantages of an optimized posterior axillary (AX) boost technique for the irradiation of supraclavicular (SC) and AX lymph nodes. Five techniques for the treatment of SC and levels I, II, and III AX lymph nodes were evaluated for 10 patients selected at random: a direct anterior field (AP); an anterior to posterior parallel pair (AP-PA); an anterior field with a posterior axillary boost (PAB); an anterior field with an anterior axillary boost (AAB); and an optimized PAB technique (OptPAB). The target coverage, hot spots, irradiated volume, and dose to organs at risk were evaluated and a statisticalmore » analysis comparison was performed. The AP technique delivered insufficient dose to the deeper AX nodes. The AP-PA technique produced larger irradiated volumes and higher mean lung doses than the other techniques. The PAB and AAB techniques originated excessive hot spots in most of the cases. The OptPAB technique produced moderate hot spots while maintaining a similar planning target volume (PTV) coverage, irradiated volume, and dose to organs at risk. This optimized technique combines the advantages of the PAB and AP-PA techniques, with moderate hot spots, sufficient target coverage, and adequate sparing of normal tissues. The presented technique is simple, fast, and easy to implement in routine clinical practice and is superior to the techniques historically used for the treatment of SC and AX lymph nodes.« less

  3. Determinants of vaccination coverage in rural Nigeria.

    PubMed

    Odusanya, Olumuyiwa O; Alufohai, Ewan F; Meurice, Francois P; Ahonkhai, Vincent I

    2008-11-05

    Childhood immunization is a cost effective public health strategy. Expanded Programme on Immunisation (EPI) services have been provided in a rural Nigerian community (Sabongidda-Ora, Edo State) at no cost to the community since 1998 through a privately financed vaccination project (private public partnership). The objective of this survey was to assess vaccination coverage and its determinants in this rural community in Nigeria A cross-sectional survey was conducted in September 2006, which included the use of interviewer-administered questionnaire to assess knowledge of mothers of children aged 12-23 months and vaccination coverage. Survey participants were selected following the World Health Organization's (WHO) immunization coverage cluster survey design. Vaccination coverage was assessed by vaccination card and maternal history. A child was said to be fully immunized if he or she had received all of the following vaccines: a dose of Bacille Calmette Guerin (BCG), three doses of oral polio (OPV), three doses of diphtheria, pertussis and tetanus (DPT), three doses of hepatitis B (HB) and one dose of measles by the time he or she was enrolled in the survey, i.e. between the ages of 12-23 months. Knowledge of the mothers was graded as satisfactory if mothers had at least a score of 3 out of a maximum of 5 points. Logistic regression was performed to identify determinants of full immunization status. Three hundred and thirty-nine mothers and 339 children (each mother had one eligible child) were included in the survey. Most of the mothers (99.1%) had very positive attitudes to immunization and > 55% were generally knowledgeable about symptoms of vaccine preventable diseases except for difficulty in breathing (as symptom of diphtheria). Two hundred and ninety-five mothers (87.0%) had a satisfactory level of knowledge. Vaccination coverage against all the seven childhood vaccine preventable diseases was 61.9% although it was significantly higher (p = 0.002) amongst those who had a vaccination card (131/188, 69.7%) than in those assessed by maternal history (79/151, 52.3%). Multiple logistic regression showed that mothers' knowledge of immunization (p = 0.006) and vaccination at a privately funded health facility (p < 0.001) were significantly correlated with the rate of full immunization. Eight years after initiation of this privately financed vaccination project (private-public partnership), vaccination coverage in this rural community is at a level that provides high protection (81%) against DPT/OPV. Completeness of vaccination was significantly correlated with knowledge of mothers on immunization and adequate attention should be given to this if high coverage levels are to be sustained.

  4. Timing of HPV vaccine intervals among United States teens with consideration to the current ACIP schedule and the WHO 2-dose schedule

    PubMed Central

    Cloessner, Emily A.; Stokley, Shannon; Yankey, David; Markowitz, Lauri E.

    2016-01-01

    Abstract The current recommendation for human papillomavirus (HPV) vaccination in the United States is for 3 doses to be administered over a 6 month period. In April 2014, the World Health Organization (WHO) recommended adoption of a 2-dose schedule, with doses spaced a minimum of 6 months apart, for teens who begin the series before age 15. We analyzed data from the 2013 National Immunization Survey-Teen to examine the timing of second and third dose receipt among US adolescents. All analyses were restricted to adolescents age 13–17 y who had adequate provider data. The Wilcoxon–Mann–Whitney test measured differences in time to receive vaccine doses among demographic and socioeconomic groups. Logistic regression identified socioeconomic characteristics associated with receiving the second dose of HPV vaccine at least 6 months after the first dose. The median time for teens to receive the second dose of HPV vaccine was 2.6 months after the first dose, and the median time to receive the third dose was 4.9 months after the second dose. Minority teens and teens living below the poverty level took significantly longer to receive doses. Among teens that initiated the HPV vaccine series before age 15 y, 28.6% received the second dose at least 6 months after the first dose. If these teens, who met the WHO criteria for up-to-date HPV vaccination, were classified as having completed the vaccination series, overall coverage in the US would increase 3.9 percentage points, with African American and Hispanic teens having the greatest increases in coverage. PMID:26587886

  5. Timing of HPV vaccine intervals among United States teens with consideration to the current ACIP schedule and the WHO 2-dose schedule.

    PubMed

    Cloessner, Emily A; Stokley, Shannon; Yankey, David; Markowitz, Lauri E

    2016-06-02

    The current recommendation for human papillomavirus (HPV) vaccination in the United States is for 3 doses to be administered over a 6 month period. In April 2014, the World Health Organization (WHO) recommended adoption of a 2-dose schedule, with doses spaced a minimum of 6 months apart, for teens who begin the series before age 15. We analyzed data from the 2013 National Immunization Survey-Teen to examine the timing of second and third dose receipt among US adolescents. All analyses were restricted to adolescents age 13-17 y who had adequate provider data. The Wilcoxon-Mann-Whitney test measured differences in time to receive vaccine doses among demographic and socioeconomic groups. Logistic regression identified socioeconomic characteristics associated with receiving the second dose of HPV vaccine at least 6 months after the first dose. The median time for teens to receive the second dose of HPV vaccine was 2.6 months after the first dose, and the median time to receive the third dose was 4.9 months after the second dose. Minority teens and teens living below the poverty level took significantly longer to receive doses. Among teens that initiated the HPV vaccine series before age 15 y, 28.6% received the second dose at least 6 months after the first dose. If these teens, who met the WHO criteria for up-to-date HPV vaccination, were classified as having completed the vaccination series, overall coverage in the US would increase 3.9 percentage points, with African American and Hispanic teens having the greatest increases in coverage.

  6. SU-E-T-575: To Analyze the Clinical Impact of Esophageal Sparing on Treatment Plans for Patients with Grade 3 Esophagitis.

    PubMed

    Niedzielski, J; Bluett, J; Williamson, R; Liao, Z; Gomez, D; Court, L

    2012-06-01

    To analyze the clinical impact of esophageal sparing on treatment plans for patients with grade 3 esophagitis. The treatment plans of 8 patients (project total: 20 patients) who were treated with IMRT and exhibited stage 3 esophagitis were re-planned to give a simulated clinical plan with dose distribution that mirrored our current clinical practice (74Gy to the target, and 5mm margins), and a plan that emphasized esophageal sparing. Doses to the esophagus, heart, cord, lung and PTV were compared. Comparing the esophageal sparing plan to the simulated clinical plan, the mean reduction in esophageal volume receiving 50, 55, 60, 65, and 70Gy were 2.0, 3.2, 5.0, 7.2, and 10.9 cm 3 , respectively. The mean reduction in the continuous length of esophagus receiving 50, 55, 60, 65, and 70Gy were 12, 24, 38, 40, and 47mm, respectively. The associated reduction in dose to 90% and 95% of the PTV was 2.2 and 3.8Gy, respectively. Of the 8 patients examined, 2 showed a significant decrease in PTV coverage (4.6Gy, 12.3Gy for 90% of PTV), 4 showed decreases under 1.1Gy, but 2 showed an increase of 1.4Gy and 0.5Gy for 90% PTV. Cord dose was maintained below 50Gy, and there was a slight increase in mean heart dose and mean lung dose of 2.4Gy, and 2.7Gy, respectively. Data will also be presented comparing these plans with the actual treated plans (for which the patients had grade 3 esophagitis) and plans that emphasize PTV coverage. Treatment planning to emphasize esophageal sparing can reduce the volume and continuous length of the esophagus which receives high doses. There is some associated modest reduction in PTV coverage. In summary, in many cases esophageal sparing can be accomplished for lung cancer cases while maintaining adequate PTV coverage, although there is variability between patients. © 2012 American Association of Physicists in Medicine.

  7. A reflection on invasive pneumococcal disease and pneumococcal conjugate vaccination coverage in children in Southern Europe (2009-2016).

    PubMed

    Moreira, Marta; Castro, Olga; Palmieri, Melissa; Efklidou, Sofia; Castagna, Stefano; Hoet, Bernard

    2017-06-03

    Higher-valent pneumococcal conjugate vaccines (PCVs) were licensed from 2009 in Europe; similar worldwide clinical effectiveness was observed for PCVs in routine use. Despite a proven medical need, PCV vaccination in Southern Europe remained suboptimal until 2015/16. We searched PubMed for manuscripts published between 2009 and mid-2016. Included manuscripts had to contain data about invasive pneumococcal disease (IPD) incidence, or vaccination coverage with higher-valent PCVs. This review represents the first analysis of vaccination coverage and impact of higher-valent PCVs on overall IPD in Southern European countries (Portugal, Spain, Italy, Greece, Cyprus). Vaccination coverage in the Portuguese private market peaked around 2008 at 75% (children ≤ 2 years) but declined to 63% in 2012. In Madrid, coverage was 95% (2007-2012) but dropped to 67% (2013/14; children ≤ 2 years) after funding termination in May 2012. PCVs were recently introduced in the national immunisation program (NIP) of Portugal (2015) and Spain (2015/16). In Italy, coverage for the complete PCV schedule (children ≤ 2 years) was 88% in 2013, although highly variable between regions (45-99%). In Greece, in 2013, 82.3% had received 3 PCV doses by 12 months, while 62.3% received the fourth dose by 24 months. Overall IPD (net benefit: effect on vaccine types, vaccine-related types, and non-vaccine types) has decreased; in Greece, pneumococcal meningitis incidence remained stable. Continued IPD surveillance or national registers using ICD-10 codes of clinically suspected IPD are necessary, with timely publicly available reports and adequate national vaccination registers to assess trends in vaccination coverage, allowing evaluation of PCVs in NIPs.

  8. A multicentre 'end to end' dosimetry audit of motion management (4DCT-defined motion envelope) in radiotherapy.

    PubMed

    Palmer, Antony L; Nash, David; Kearton, John R; Jafari, Shakardokht M; Muscat, Sarah

    2017-12-01

    External dosimetry audit is valuable for the assurance of radiotherapy quality. However, motion management has not been rigorously audited, despite its complexity and importance for accuracy. We describe the first end-to-end dosimetry audit for non-SABR (stereotactic ablative body radiotherapy) lung treatments, measuring dose accumulation in a moving target, and assessing adequacy of target dose coverage. A respiratory motion lung-phantom with custom-designed insert was used. Dose was measured with radiochromic film, employing triple-channel dosimetry and uncertainty reduction. The host's 4DCT scan, outlining and planning techniques were used. Measurements with the phantom static and then moving at treatment delivery separated inherent treatment uncertainties from motion effects. Calculated and measured dose distributions were compared by isodose overlay, gamma analysis, and we introduce the concept of 'dose plane histograms' for clinically relevant interpretation of film dosimetry. 12 radiotherapy centres and 19 plans were audited: conformal, IMRT (intensity modulated radiotherapy) and VMAT (volumetric modulated radiotherapy). Excellent agreement between planned and static-phantom results were seen (mean gamma pass 98.7% at 3% 2 mm). Dose blurring was evident in the moving-phantom measurements (mean gamma pass 88.2% at 3% 2 mm). Planning techniques for motion management were adequate to deliver the intended moving-target dose coverage. A novel, clinically-relevant, end-to-end dosimetry audit of motion management strategies in radiotherapy is reported. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. 4D-Listmode-PET-CT and 4D-CT for optimizing PTV margins in gastric lymphoma : Determination of intra- and interfractional gastric motion.

    PubMed

    Reinartz, Gabriele; Haverkamp, Uwe; Wullenkord, Ramona; Lehrich, Philipp; Kriz, Jan; Büther, Florian; Schäfers, Klaus; Schäfers, Michael; Eich, Hans Theodor

    2016-05-01

    New imaging protocols for radiotherapy in localized gastric lymphoma were evaluated to optimize planning target volume (PTV) margin and determine intra-/interfractional variation of the stomach. Imaging of 6 patients was explored prospectively. Intensity-modulated radiotherapy (IMRT) planning was based on 4D/3D imaging of computed tomography (CT) and positron-emission tomography (PET)-CT. Static and motion gross tumor volume (sGTV and mGTV, respectively) were distinguished by defining GTV (empty stomach), clinical target volume (CTV = GTV + 5 mm margin), PTV (GTV + 10/15/20/25 mm margins)  plus paraaortic lymph nodes and proximal duodenum. Overlap of 4D-Listmode-PET-based mCTV with 3D-CT-based PTV (increasing margins) and V95/D95 of mCTV were evaluated. Gastric shifts were determined using online cone-beam CT. Dose contribution to organs at risk was assessed. The 4D data demonstrate considerable intra-/interfractional variation of the stomach, especially along the vertical axis. Conventional 3D-CT planning utilizing advancing PTV margins of 10/15/20/25 mm resulted in rising dose coverage of mCTV (4D-Listmode-PET-Summation-CT) and rising D95 and V95 of mCTV. A PTV margin of 15 mm was adequate in 3 of 6 patients, a PTV margin of 20 mm was adequate in 4 of 6 patients, and a PTV margin of 25 mm was adequate in 5 of 6 patients. IMRT planning based on 4D-PET-CT/4D-CT together with online cone-beam CT is advisable to individualize the PTV margin and optimize target coverage in gastric lymphoma.

  10. SU-F-19A-03: Dosimetric Advantages in Critical Structure Dose Sparing by Using a Multichannel Cylinder in High Dose Rate Brachytherapy to Treat Vaginal Cuff Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Syh, J; Syh, J; Patel, B

    2014-06-15

    Purpose: The multichannel cylindrical vaginal applicator is a variation of traditional single channel cylindrical vaginal applicator. The multichannel applicator has additional peripheral channels that provide more flexibility in the planning process. The dosimetric advantage is to reduce dose to adjacent organ at risk (OAR) such as bladder and rectum while maintaining target coverage with the dose optimization from additional channels. Methods: Vaginal HDR brachytherapy plans are all CT based. CT images were acquired in 2 mm thickness to keep integrity of cylinder contouring. The CTV of 5mm Rind with prescribed treatment length was reconstructed from 5mm expansion of inserted cylinder.more » The goal was 95% of CTV covered by 95% of prescribed dose in both single channel planning (SCP)and multichannel planning (MCP) before proceeding any further optimization for dose reduction to critical structures with emphasis on D2cc and V2Gy . Results: This study demonstrated noticeable dose reduction to OAR was apparent in multichannel plans. The D2cc of the rectum and bladder were showing the reduced dose for multichannel versus single channel. The V2Gy of the rectum was 93.72% and 83.79% (p=0.007) for single channel and multichannel respectively (Figure 1 and Table 1). To assure adequate coverage to target while reducing the dose to the OAR without any compromise is the main goal in using multichannel vaginal applicator in HDR brachytherapy. Conclusion: Multichannel plans were optimized using anatomical based inverse optimization algorithm of inverse planning simulation annealing. The optimization solution of the algorithm was to improve the clinical target volume dose coverage while reducing the dose to critical organs such as bladder, rectum and bowels. The comparison between SCP and MCP demonstrated MCP is superior to SCP where the dwell positions were based on geometric array only. It concluded that MCP is preferable and is able to provide certain features superior to SCP.« less

  11. Evidence-Based Assessment of Depression in Adults

    ERIC Educational Resources Information Center

    Joiner, Thomas E.; Walker, Rheeda L.; Pettit, Jeremy W.; Perez, Marisol; Cukrowicz, Kelly C.

    2005-01-01

    From diverse perspectives, there is little doubt that depressive symptoms cohere to form a valid and distinct syndrome. Research indicates that an evidence-based assessment of depression would include (a) measures with adequate psychometric properties; (b) adequate coverage of symptoms; (c) adequate coverage of depressed mood, anhedonia, and…

  12. Robustness Recipes for Minimax Robust Optimization in Intensity Modulated Proton Therapy for Oropharyngeal Cancer Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Voort, Sebastian van der; Section of Nuclear Energy and Radiation Applications, Department of Radiation, Science and Technology, Delft University of Technology, Delft; Water, Steven van de

    Purpose: We aimed to derive a “robustness recipe” giving the range robustness (RR) and setup robustness (SR) settings (ie, the error values) that ensure adequate clinical target volume (CTV) coverage in oropharyngeal cancer patients for given gaussian distributions of systematic setup, random setup, and range errors (characterized by standard deviations of Σ, σ, and ρ, respectively) when used in minimax worst-case robust intensity modulated proton therapy (IMPT) optimization. Methods and Materials: For the analysis, contoured computed tomography (CT) scans of 9 unilateral and 9 bilateral patients were used. An IMPT plan was considered robust if, for at least 98% of themore » simulated fractionated treatments, 98% of the CTV received 95% or more of the prescribed dose. For fast assessment of the CTV coverage for given error distributions (ie, different values of Σ, σ, and ρ), polynomial chaos methods were used. Separate recipes were derived for the unilateral and bilateral cases using one patient from each group, and all 18 patients were included in the validation of the recipes. Results: Treatment plans for bilateral cases are intrinsically more robust than those for unilateral cases. The required RR only depends on the ρ, and SR can be fitted by second-order polynomials in Σ and σ. The formulas for the derived robustness recipes are as follows: Unilateral patients need SR = −0.15Σ{sup 2} + 0.27σ{sup 2} + 1.85Σ − 0.06σ + 1.22 and RR=3% for ρ = 1% and ρ = 2%; bilateral patients need SR = −0.07Σ{sup 2} + 0.19σ{sup 2} + 1.34Σ − 0.07σ + 1.17 and RR=3% and 4% for ρ = 1% and 2%, respectively. For the recipe validation, 2 plans were generated for each of the 18 patients corresponding to Σ = σ = 1.5 mm and ρ = 0% and 2%. Thirty-four plans had adequate CTV coverage in 98% or more of the simulated fractionated treatments; the remaining 2 had adequate coverage in 97.8% and 97.9%. Conclusions: Robustness recipes were derived that can be used in minimax robust optimization of IMPT treatment plans to ensure adequate CTV coverage for oropharyngeal cancer patients.« less

  13. Proton therapy of prostate cancer by anterior-oblique beams: implications of setup and anatomy variations

    NASA Astrophysics Data System (ADS)

    Moteabbed, M.; Trofimov, A.; Sharp, G. C.; Wang, Y.; Zietman, A. L.; Efstathiou, J. A.; Lu, H.-M.

    2017-03-01

    Proton therapy of prostate by anterior beams could offer an attractive option for treating patients with hip prosthesis and limiting the high-dose exposure to the rectum. We investigated the impact of setup and anatomy variations on the anterior-oblique (AO) proton plan dose, and strategies to manage these effects via range verification and adaptive delivery. Ten patients treated by bilateral (BL) passive-scattering proton therapy (79.2 Gy in 44 fractions) who underwent weekly verification CT scans were selected. Plans with AO beams were additionally created. To isolate the effect of daily variations, initial AO plans did not include range uncertainty margins. The use of fixed planning margins and adaptive range adjustments to manage these effects was investigated. For each case, the planned dose was recalculated on weekly CTs, and accumulated on the simulation CT using deformable registration to approximate the delivered dose. Planned and accumulated doses were compared for each scenario to quantify dose deviations induced by variations. The possibility of estimating the necessary range adjustments before each treatment was explored by simulating the procedure of a diode-based in vivo range verification technique, which would potentially be used clinically. The average planned rectum, penile bulb and femoral heads mean doses were smaller for initial AO compared to BL plans (by 8.3, 16.1 and 25.9 Gy, respectively). After considering interfractional variations in AO plans, the target coverage was substantially reduced. The maximum reduction of V 79.2/D 95/D mean/EUD for AO (without distal margins) (25.3%/10.7/1.6/4.9 Gy, respectively) was considerably larger than BL plans. The loss of coverage was mainly related to changes in water equivalent path length of the prostate after fiducial-based setup, caused by discrepancies in patient anterior surface and bony-anatomy alignment. Target coverage was recovered partially when using fixed planning margins, and fully when applying adaptive range adjustments. The accumulated organs-at-risk dose for AO beams after range adjustment demonstrated full sparing of femoral heads and superior sparing of penile bulb and rectum compared to the conventional BL cases. Our study indicates that using AO beams makes prostate treatment more susceptible to target underdose induced by interfractional variations. Adaptive range verification/adjustment may facilitate the use of anterior beam approaches, and ensure adequate target coverage in every fraction of the treatment.

  14. Determinants of vaccination coverage in rural Nigeria

    PubMed Central

    Odusanya, Olumuyiwa O; Alufohai, Ewan F; Meurice, Francois P; Ahonkhai, Vincent I

    2008-01-01

    Background Childhood immunization is a cost effective public health strategy. Expanded Programme on Immunisation (EPI) services have been provided in a rural Nigerian community (Sabongidda-Ora, Edo State) at no cost to the community since 1998 through a privately financed vaccination project (private public partnership). The objective of this survey was to assess vaccination coverage and its determinants in this rural community in Nigeria Methods A cross-sectional survey was conducted in September 2006, which included the use of interviewer-administered questionnaire to assess knowledge of mothers of children aged 12–23 months and vaccination coverage. Survey participants were selected following the World Health Organization's (WHO) immunization coverage cluster survey design. Vaccination coverage was assessed by vaccination card and maternal history. A child was said to be fully immunized if he or she had received all of the following vaccines: a dose of Bacille Calmette Guerin (BCG), three doses of oral polio (OPV), three doses of diphtheria, pertussis and tetanus (DPT), three doses of hepatitis B (HB) and one dose of measles by the time he or she was enrolled in the survey, i.e. between the ages of 12–23 months. Knowledge of the mothers was graded as satisfactory if mothers had at least a score of 3 out of a maximum of 5 points. Logistic regression was performed to identify determinants of full immunization status. Results Three hundred and thirty-nine mothers and 339 children (each mother had one eligible child) were included in the survey. Most of the mothers (99.1%) had very positive attitudes to immunization and > 55% were generally knowledgeable about symptoms of vaccine preventable diseases except for difficulty in breathing (as symptom of diphtheria). Two hundred and ninety-five mothers (87.0%) had a satisfactory level of knowledge. Vaccination coverage against all the seven childhood vaccine preventable diseases was 61.9% although it was significantly higher (p = 0.002) amongst those who had a vaccination card (131/188, 69.7%) than in those assessed by maternal history (79/151, 52.3%). Multiple logistic regression showed that mothers' knowledge of immunization (p = 0.006) and vaccination at a privately funded health facility (p < 0.001) were significantly correlated with the rate of full immunization. Conclusion Eight years after initiation of this privately financed vaccination project (private-public partnership), vaccination coverage in this rural community is at a level that provides high protection (81%) against DPT/OPV. Completeness of vaccination was significantly correlated with knowledge of mothers on immunization and adequate attention should be given to this if high coverage levels are to be sustained. PMID:18986544

  15. Fast and robust online adaptive planning in stereotactic MR-guided adaptive radiation therapy (SMART) for pancreatic cancer.

    PubMed

    Bohoudi, O; Bruynzeel, A M E; Senan, S; Cuijpers, J P; Slotman, B J; Lagerwaard, F J; Palacios, M A

    2017-12-01

    To implement a robust and fast stereotactic MR-guided adaptive radiation therapy (SMART) online strategy in locally advanced pancreatic cancer (LAPC). SMART strategy for plan adaptation was implemented with the MRIdian system (ViewRay Inc.). At each fraction, OAR (re-)contouring is done within a distance of 3cm from the PTV surface. Online plan re-optimization is based on robust prediction of OAR dose and optimization objectives, obtained by building an artificial neural network (ANN). Proposed limited re-contouring strategy for plan adaptation (SMART 3CM ) is evaluated by comparing 50 previously delivered fractions against a standard (re-)planning method using full-scale OAR (re-)contouring (FULLOAR). Plan quality was assessed using PTV coverage (V 95% , D mean , D 1cc ) and institutional OAR constraints (e.g. V 33Gy ). SMART 3CM required a significant lower number of optimizations than FULLOAR (4 vs 18 on average) to generate a plan meeting all objectives and institutional OAR constraints. PTV coverage with both strategies was identical (mean V 95% =89%). Adaptive plans with SMART 3CM exhibited significant lower intermediate and high doses to all OARs than FULLOAR, which also failed in 36% of the cases to adhere to the V 33Gy dose constraint. SMART 3CM approach for LAPC allows good OAR sparing and adequate target coverage while requiring only limited online (re-)contouring from clinicians. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Correlation between measles vaccine doses: implications for the maintenance of elimination.

    PubMed

    McKee, A; Ferrari, M J; Shea, K

    2018-03-01

    Measles eradication efforts have been successful at achieving elimination in many countries worldwide. Such countries actively work to maintain this elimination by continuing to improve coverage of two routine doses of measles vaccine following measles elimination. While improving measles vaccine coverage is always beneficial, we show, using a steady-state analysis of a dynamical model, that the correlation between populations receiving the first and second routine dose also has a significant impact on the population immunity achieved by a specified combination of first and second dose coverage. If the second dose is administered to people independently of whether they had the first dose, high second-dose coverage improves the proportion of the population receiving at least one dose, and will have a large effect on population immunity. If the second dose is administered only to people who have had the first dose, high second-dose coverage reduces the rate of primary vaccine failure, but does not reach people who missed the first dose; this will therefore have a relatively small effect on population immunity. When doses are administered dependently, and assuming the first dose has higher coverage, increasing the coverage of the first dose has a larger impact on population immunity than does increasing the coverage of the second. Correlation between vaccine doses has a significant impact on the level of population immunity maintained by current vaccination coverage, potentially outweighing the effects of age structure and, in some cases, recent improvements in vaccine coverage. It is therefore important to understand the correlation between vaccine doses as such correlation may have a large impact on the effectiveness of measles vaccination strategies.

  17. A dosimetric comparison of 3D-CRT, IMRT, and static tomotherapy with an SIB for large and small breast volumes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michalski, Andrea; Central Coast Cancer Centre, Gosford Hospital, Gosford, New South Wales; Atyeo, John, E-mail: john.atyeo@sydney.edu.au

    2014-07-01

    Radiation therapy to the breast is a complex task, with many different techniques that can be employed to ensure adequate dose target coverage while minimizing doses to the organs at risk. This study compares the dose planning outcomes of 3 radiation treatment modalities, 3 dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and static tomotherapy, for left-sided whole-breast radiation treatment with a simultaneous integrated boost (SIB). Overall, 20 patients with left-sided breast cancer were separated into 2 cohorts, small and large, based on breast volume. Dose plans were produced for each patient using 3D-CRT, IMRT, and static tomotherapy. Allmore » patients were prescribed a dose of 45 Gy in 20 fractions to the breast with an SIB of 56 Gy in 20 fractions to the tumor bed and normalized so that D{sub 98%} > 95% of the prescription dose. Dosimetric comparisons were made between the 3 modalities and the interaction of patient size. All 3 modalities offered adequate planning target volume (PTV) coverage with D{sub 98%} > 95% and D{sub 2%} < 107%. Static tomotherapy offered significantly improved (p = 0.006) dose homogeneity to the PTV{sub boost} {sub eval} (0.079 ± 0.011) and breast minus the SIB volume (Breast{sub SIB}) (p < 0.001, 0.15 ± 0.03) compared with the PTV{sub boost} {sub eval} (0.085 ± 0.008, 0.088 ± 0.12) and Breast{sub SIB} (0.22 ± 0.05, 0.23 ± 0.03) for IMRT and 3D-CRT, respectively. Static tomotherapy also offered statistically significant reductions (p < 0.001) in doses to the ipsilateral lung mean dose of 6.79 ± 2.11 Gy compared with 7.75 ± 2.54 Gy and 8.29 ± 2.76 Gy for IMRT and 3D-CRT, respectively, and significantly (p < 0.001) reduced heart doses (mean = 2.83 ± 1.26 Gy) compared to both IMRT and 3D-CRT (mean = 3.70 ± 1.44 Gy and 3.91 ± 1.58 Gy). Static tomotherapy is the dosimetrically superior modality for the whole breast with an SIB compared with IMRT and 3D-CRT. IMRT is superior to 3D-CRT in both PTV dose conformity and reduction of mean doses to the ipsilateral lung.« less

  18. Occupational Exposure of the Eye Lens in Interventional Procedures: How to Assess and Manage Radiation Dose.

    PubMed

    Ciraj-Bjelac, Olivera; Carinou, Eleftheria; Ferrari, Paolo; Gingaume, Merce; Merce, Marta Sans; O'Connor, Una

    2016-11-01

    Occupational exposure from interventional x-ray procedures is one of the areas in which increased eye lens exposure may occur. Accurate dosimetry is an important element to investigate the correlation of observed radiation effects with radiation dose, to verify the compliance with regulatory dose limits, and to optimize radiation protection practice. The objective of this work is to review eye lens dose levels in clinical practice that may occur from the use of ionizing radiation. The use of a dedicated eye lens dosimeter is the recommended methodology; however, in practice it cannot always be easily implemented. Alternatively, the eye lens dose could be assessed from measurements of other dosimetric quantities or other indirect parameters, such as patient dose. The practical implementation of monitoring eye lens doses and the use of adequate protective equipment still remains a challenge. The use of lead glasses with a good fit to the face, appropriate lateral coverage, and/or ceiling-suspended screens is recommended in workplaces with potential high eye lens doses. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  19. Cardiac Dose Reduction with Deep-Inspiratory Breath Hold Technique of Radiotherapy for Left-Sided Breast Cancer.

    PubMed

    Sripathi, Lalitha Kameshwari; Ahlawat, Parveen; Simson, David K; Khadanga, Chira Ranjan; Kamarsu, Lakshmipathi; Surana, Shital Kumar; Arasu, Kavi; Singh, Harpreet

    2017-01-01

    Different techniques of radiation therapy have been studied to reduce the cardiac dose in left breast cancer. In this prospective dosimetric study, the doses to heart as well as other organs at risk (OAR) were compared between free-breathing (FB) and deep inspiratory breath hold (DIBH) techniques in intensity modulated radiotherapy (IMRT) and opposed-tangent three-dimensional radiotherapy (3DCRT) plans. Fifteen patients with left-sided breast cancer underwent computed tomography simulation and images were obtained in both FB and DIBH. Radiotherapy plans were generated with 3DCRT and IMRT techniques in FB and DIBH images in each patient. Target coverage, conformity index, homogeneity index, and mean dose to heart (Heart D mean ), left lung, left anterior descending artery (LAD) and right breast were compared between the four plans using the Wilcoxon signed rank test. Target coverage was adequate with both 3DCRT and IMRT plans, but IMRT plans showed better conformity and homogeneity. A statistically significant dose reduction of all OARs was found with DIBH. 3DCRT DIBH decreased the Heart D mean by 53.5% (7.1 vs. 3.3 Gy) and mean dose to LAD by 28% compared to 3DCRT FB . IMRT further lowered mean LAD dose by 18%. Heart D mean was lower with 3DCRT DIBH over IMRT DIBH (3.3 vs. 10.2 Gy). Mean dose to the contralateral breast was also lower with 3DCRT over IMRT (0.32 vs. 3.35 Gy). Mean dose and the V 20 of ipsilateral lung were lower with 3DCRT DIBH over IMRT DIBH (13.78 vs. 18.9 Gy) and (25.16 vs. 32.95%), respectively. 3DCRT DIBH provided excellent dosimetric results in patients with left-sided breast cancer without the need for IMRT.

  20. Cardiac Dose Reduction with Deep-Inspiratory Breath Hold Technique of Radiotherapy for Left-Sided Breast Cancer

    PubMed Central

    Sripathi, Lalitha Kameshwari; Ahlawat, Parveen; Simson, David K; Khadanga, Chira Ranjan; Kamarsu, Lakshmipathi; Surana, Shital Kumar; Arasu, Kavi; Singh, Harpreet

    2017-01-01

    Introduction: Different techniques of radiation therapy have been studied to reduce the cardiac dose in left breast cancer. Aim: In this prospective dosimetric study, the doses to heart as well as other organs at risk (OAR) were compared between free-breathing (FB) and deep inspiratory breath hold (DIBH) techniques in intensity modulated radiotherapy (IMRT) and opposed-tangent three-dimensional radiotherapy (3DCRT) plans. Materials and Methods: Fifteen patients with left-sided breast cancer underwent computed tomography simulation and images were obtained in both FB and DIBH. Radiotherapy plans were generated with 3DCRT and IMRT techniques in FB and DIBH images in each patient. Target coverage, conformity index, homogeneity index, and mean dose to heart (Heart Dmean), left lung, left anterior descending artery (LAD) and right breast were compared between the four plans using the Wilcoxon signed rank test. Results: Target coverage was adequate with both 3DCRT and IMRT plans, but IMRT plans showed better conformity and homogeneity. A statistically significant dose reduction of all OARs was found with DIBH. 3DCRTDIBH decreased the Heart Dmean by 53.5% (7.1 vs. 3.3 Gy) and mean dose to LAD by 28% compared to 3DCRTFB. IMRT further lowered mean LAD dose by 18%. Heart Dmean was lower with 3DCRTDIBH over IMRTDIBH (3.3 vs. 10.2 Gy). Mean dose to the contralateral breast was also lower with 3DCRT over IMRT (0.32 vs. 3.35 Gy). Mean dose and the V20 of ipsilateral lung were lower with 3DCRTDIBH over IMRTDIBH (13.78 vs. 18.9 Gy) and (25.16 vs. 32.95%), respectively. Conclusions: 3DCRTDIBH provided excellent dosimetric results in patients with left-sided breast cancer without the need for IMRT. PMID:28974856

  1. Conformal and intensity modulated irradiation of head and neck cancer: the potential for improved target irradiation, salivary gland function, and quality of life.

    PubMed

    Eisbruch, A; Dawson, L A; Kim, H M; Bradford, C R; Terrell, J E; Chepeha, D B; Teknos, T N; Anzai, Y; Marsh, L H; Martel, M K; Ten Haken, R K; Wolf, G T; Ship, J A

    1999-01-01

    To develop techniques which facilitate sparing of the major salivary glands while adequately treating the targets in patients requiring comprehensive bilateral neck irradiation (RT). Conformal and static, multisegmental intensity modulated (IMRT) techniques have been developed. The salivary flow rates before and periodically after RT have been measured selectively from each major salivary gland and the residual flows correlated with glands' dose volume histograms. Subjective xerostomia questionnaires have been developed and validated. The pattern of local-regional recurrences has been examined using CT scans at the time of recurrence, transferring the recurrence volumes to the planning CT scans and regenerating the dose distributions at the recurrence sites. Target coverage and dose homogeneity in IMRT treatment plans were found to be significantly better than standard RT plans. Significant parotid gland sparing was achieved. The relationships among dose, irradiated volume and saliva flow rates from the parotid glands were characterized by dose and volume thresholds. A mean dose of 26 Gy was found to be the threshold for stimulated saliva. Subjective xerostomia was significantly reduced in patients irradiated with parotid sparing techniques, compared to patients with similar tumors treated with standard RT. The large majority of recurrences occurred inside high-risk targets. Tangible gains in salivary gland sparing and target coverage are being achieved and an improvement in some measures of quality of life is suggested by our findings. A mean parotid gland dose of < or = 26 Gy should be a planning objective if significant parotid function preservation is desired. The pattern of recurrence suggests that careful escalation of the dose to targets judged to be at highest risk may improve tumor control.

  2. An evaluation of voluntary 2-dose varicella vaccination coverage in New York City public schools.

    PubMed

    Doll, Margaret K; Rosen, Jennifer B; Bialek, Stephanie R; Szeto, Hiram; Zimmerman, Christopher M

    2015-05-01

    We assessed coverage for 2-dose varicella vaccination, which is not required for school entry, among New York City public school students and examined characteristics associated with receipt of 2 doses. We measured receipt of either at least 1 or 2 doses of varicella vaccine among students aged 4 years and older in a sample of 336 public schools (n = 223 864 students) during the 2010 to 2011 school year. Data came from merged student vaccination records from 2 administrative data systems. We conducted multivariable regression to assess associations of age, gender, race/ethnicity, and school location with 2-dose prevalence. Coverage with at least 1 varicella dose was 96.2% (95% confidence interval [CI] = 96.2%, 96.3%); coverage with at least 2 doses was 64.8% (95% CI = 64.6%, 64.9%). Increasing student age, non-Hispanic White race/ethnicity, and attendance at school in Staten Island were associated with lower 2-dose coverage. A 2-dose varicella vaccine requirement for school entry would likely improve 2-dose coverage, eliminate coverage disparities, and prevent disease.

  3. Human papillomavirus vaccination coverage using two-dose or three-dose schedule criteria.

    PubMed

    Lin, Xia; Rodgers, Loren; Zhu, Liping; Stokley, Shannon; Meites, Elissa; Markowitz, Lauri E

    2017-10-13

    In October 2016, the Advisory Committee on Immunization Practices (ACIP) updated the human papillomavirus (HPV) vaccination recommendation to include a 2-dose schedule for U.S. adolescents initiating the vaccine series before their 15th birthday. We analyzed records for >4million persons aged 9-17years receiving any HPV vaccine by the end of each quarter during January 1, 2014-September 30, 2016 from six Immunization Information Systems Sentinel Sites, and reclassified HPV vaccination up-to-date coverage according to the updated recommendations. Compared with HPV vaccination up-to-date coverage by the 3-dose schedule only, including criteria for either a 2-dose or 3-dose schedule increased up-to-date coverage in 11-12, 13-14, and 15-17 year-olds by 4.5-8.5 percentage points. The difference between 3-dose up-to-date coverage and 2- or 3-dose up-to-date coverage was greatest in late 2016. These data provide baseline HPV vaccination coverage using current ACIP recommendations. Published by Elsevier Ltd.

  4. Insurance company denial of payment and enforced changes in the type and dose of opioid analgesics for patients with cancer pain.

    PubMed

    Tanco, Kimberson; Bruera, Sofia E; Bruera, Eduardo

    2014-12-01

    Opioids are the mainstay of treatment for moderate to severe cancer pain. The variations in average monthly cost can make it difficult for most patients to procure them without adequate insurance coverage. There are increasing numbers of denials of payment and statements made by insurance agents and other sources regarding inappropriate opioid use, resulting in severe pain and emotional distress for cancer patients and their families. This case series describes five events where the insurer was a major barrier to opioid access.

  5. Three-dimensional conformal simultaneously integrated boost technique for breast-conserving radiotherapy.

    PubMed

    van der Laan, Hans Paul; Dolsma, Wil V; Maduro, John H; Korevaar, Erik W; Hollander, Miranda; Langendijk, Johannes A

    2007-07-15

    To compare the target coverage and normal tissue dose with the simultaneously integrated boost (SIB) and the sequential boost technique in breast cancer, and to evaluate the incidence of acute skin toxicity in patients treated with the SIB technique. Thirty patients with early-stage left-sided breast cancer underwent breast-conserving radiotherapy using the SIB technique. The breast and boost planning target volumes (PTVs) were treated simultaneously (i.e., for each fraction, the breast and boost PTVs received 1.81 Gy and 2.3 Gy, respectively). Three-dimensional conformal beams with wedges were shaped and weighted using forward planning. Dose-volume histograms of the PTVs and organs at risk with the SIB technique, 28 x (1.81 + 0.49 Gy), were compared with those for the sequential boost technique, 25 x 2 Gy + 8 x 2 Gy. Acute skin toxicity was evaluated for 90 patients treated with the SIB technique according to Common Terminology Criteria for Adverse Events, version 3.0. PTV coverage was adequate with both techniques. With SIB, more efficiently shaped boost beams resulted in smaller irradiated volumes. The mean volume receiving > or =107% of the breast dose was reduced by 20%, the mean volume outside the boost PTV receiving > or =95% of the boost dose was reduced by 54%, and the mean heart and lung dose were reduced by 10%. Of the evaluated patients, 32.2% had Grade 2 or worse toxicity. The SIB technique is proposed for standard use in breast-conserving radiotherapy because of its dose-limiting capabilities, easy implementation, reduced number of treatment fractions, and relatively low incidence of acute skin toxicity.

  6. Helical tomotherapy significantly reduces dose to normal tissues when compared to 3D-CRT for locally advanced rectal cancer.

    PubMed

    Jhaveri, Pavan M; Teh, Bin S; Paulino, Arnold C; Smiedala, Mindy J; Fahy, Bridget; Grant, Walter; McGary, John; Butler, E Brian

    2009-10-01

    Combined modality treatment (neoadjuvant chemoradiotherapy followed by surgery) for locally advanced rectal cancer requires special attention to various organs at risk (OAR). As a result, the use of conformal dose delivery methods has become more common in this disease setting. Helical tomotherapy is an image-guided intensity modulated delivery system that delivers dose in a fan-beam manner at 7 degree intervals around the patient and can potentially limit normal tissue from high dose radiation while adequately treating targets. In this study we dosimetrically compare helical tomotherapy to 3D-CRT for stage T3 rectal cancer. The helical tomotherapy plans were optimized in the TomoPlan system to achieve an equivalent uniform dose of 45 Gy for 10 patients with T3N0M0 disease that was at least 5cm from the anal verge. The GTV included the rectal thickening and mass evident on colonoscopy and CT scan as well as with the help of a colorectal surgeon. The CTV included the internal iliac, obturator, and pre-sacral lymphatic chains. The OAR that were outlined included the small bowel, pelvic bone marrow, femoral heads, and bladder. Anatom-e system was used to assist in delineating GTV, CTV and OAR. These 10 plans were then duplicated and optimized into 3-field 3D-CRT plans within the Pinnacle planning system.The V[45], V[40], V[30], V[20], V[10], and mean dose to the OAR were compared between the helical tomotherapy and 3D-CRT plans. Statistically significant differences were achieved in the doses to all OAR, including all volumes and means except for V[10] for the small bowel and the femoral heads. Adequate dosimetric coverage of targets were achieved with both helical tomotherapy and 3D-CRT. Helical tomotherapy reduces the volume of normal tissue receiving high-dose RT when compared to 3D-CRT treatment. Both modalities adequately dose the tumor. Clinical studies addressing the dosimetric benefits are on-going.

  7. Real-time computed tomography dosimetry during ultrasound-guided brachytherapy for prostate cancer.

    PubMed

    Kaplan, Irving D; Meskell, Paul; Oldenburg, Nicklas E; Saltzman, Brian; Kearney, Gary P; Holupka, Edward J

    2006-01-01

    Ultrasound-guided implantation of permanent radioactive seeds is a treatment option for localized prostate cancer. Several techniques have been described for the optimal placement of the seeds in the prostate during this procedure. Postimplantation dosimetric calculations are performed after the implant. Areas of underdosing can only be corrected with either an external beam boost or by performing a second implant. We demonstrate the feasibility of performing computed tomography (CT)-based postplanning during the ultrasound-guided implant and subsequently correcting for underdosed areas. Ultrasound-guided brachytherapy is performed on a modified CT table with general anesthesia. The postplanning CT scan is performed after the implant, while the patient is still under anesthesia. Additional seeds are implanted into "cold spots," and the resultant dosimetry confirmed with CT. Intraoperative postplanning was successfully performed. Dose-volume histograms demonstrated adequate dose coverage during the initial implant, but on detailed analysis, for some patients, areas of underdosing were observed either at the apex or the peripheral zone. Additional seeds were implanted to bring these areas to prescription dose. Intraoperative postplanning is feasible during ultrasound-guided brachytherapy for prostate cancer. Although the postimplant dose-volume histograms for all patients, before the implantation of additional seeds, were adequate according to the American Brachytherapy Society criteria, specific critical areas can be underdosed. Additional seeds can then be implanted to optimize the dosimetry and reduce the risk of underdosing areas of cancer.

  8. An Evaluation of Voluntary 2-Dose Varicella Vaccination Coverage in New York City Public Schools

    PubMed Central

    Rosen, Jennifer B.; Bialek, Stephanie R.; Szeto, Hiram; Zimmerman, Christopher M.

    2015-01-01

    Objectives. We assessed coverage for 2-dose varicella vaccination, which is not required for school entry, among New York City public school students and examined characteristics associated with receipt of 2 doses. Methods. We measured receipt of either at least 1 or 2 doses of varicella vaccine among students aged 4 years and older in a sample of 336 public schools (n = 223 864 students) during the 2010 to 2011 school year. Data came from merged student vaccination records from 2 administrative data systems. We conducted multivariable regression to assess associations of age, gender, race/ethnicity, and school location with 2-dose prevalence. Results. Coverage with at least 1 varicella dose was 96.2% (95% confidence interval [CI] = 96.2%, 96.3%); coverage with at least 2 doses was 64.8% (95% CI = 64.6%, 64.9%). Increasing student age, non-Hispanic White race/ethnicity, and attendance at school in Staten Island were associated with lower 2-dose coverage. Conclusions. A 2-dose varicella vaccine requirement for school entry would likely improve 2-dose coverage, eliminate coverage disparities, and prevent disease. PMID:25521904

  9. Timeliness and risk factors associated with delay for pneumococcal conjugate 10-valent routine immunization in Brazilian children.

    PubMed

    Sartori, Ana Lucia; Minamisava, Ruth; Afonso, Eliane Terezinha; Policena, Gabriela Moreira; Pessoni, Grécia Carolina; Bierrenbach, Ana Luiza; Andrade, Ana Lucia

    2017-02-15

    Vaccination coverage is the usual metrics to evaluate the immunization programs performance. For the 10-valent pneumococcal conjugate (PCV10) vaccine, measuring the delay of vaccination is also important, particularly as younger children are at increased risk of disease. Routinely collected administrative data was used to assess the timeliness of PCV10 vaccination, and the factors associated with delay to receive the first and second doses, and the completion of the PCV10 3+1 schedule. A population-based retrospective cohort study was conducted with children born in 2012 in Central Brazil. Children who received the PCV10 first dose in public health services were followed-up until 23months of age. Timeliness of receiving each PCV10 dose at any given age was defined as receiving the dose within 28days grace period from the recommended age by the National Immunization Program. Log-binomial regression models were used to examine risk factors for delays of the first dose and the completion PCV10 3+1 schedule. In total, 14,282 children were included in the cohort of study. Delayed vaccination occurred in 9.4%, 23.8%, 36.8% and 39.9% children for the first, second, third and the booster doses, respectively. A total of 1912 children (12.8% of the cohort) were not adequately vaccinated at the 6months of life; 1,071 (7%) received the second dose after 6months of age, 784 (5.4%) did not receive the second dose, and 57 (0.4%) received the first dose after six months of life. A considerable delay was found in PCV10 third and booster doses. Almost 2 thousand children had not received the recommended PCV10 doses at 6months of age. Timeliness of vaccination is an issue in Brazil although high vaccination coverages. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. SU-F-T-85: Energy Modulated Electron Postmastectomy Unreconstructed (PU) Chest Wall (CW) Irradiation Technique to Achieve Heart Sparing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong, L; Ballangrud, A; Mechalakos, J

    Purpose: For left-sided PU patients requiring CW and nodal irradiation, sometimes partial wide tangents (PWT) are not feasible due to abnormal chest wall contour or heart position close to the anterior chest wall or unusual wide excision scar. We developed an energy modulated electron chest wall irradiation technique that will achieve heart sparing. Methods: Ten left-sided PU patients were selected for this dosimetry study. If PWT were used, the amount of the ipsilateral lung would be ranged 3.4 to 4.4 cm, and the amount of heart would be ranged 1.3 to 3.8 cm. We used electron paired fields that matchedmore » on the skin to achieve dose conformity to the chest wall. The enface electron fields were designed at extended SSD from a single isocenter and gantry angle with different energy beams using different cutout. Lower energy was used in the central chest wall part and higher energy was used in the periphery of the chest wall. Bolus was used for the electron fields to ensure adequate skin dose coverage. The electron fields were matched to the photon supra-clavicle field in the superior region. Daily field junctions were used to feather the match lines between all the fields. Target volumes and normal tissues were drawn according to institutional protocols. Prescription dose was 2Gy per fraction for a total 50Gy. Dose calculations were done with Eclipse EMC-11031 for Electron and AAA-11031 for photons. Results: Six patients were planned using 6/9MeV, three using 9/12MeV and one 6/12MeV. Target volumes achieved adequate coverage. For heart, V30Gy, V20Gy and Mean Dose were 0.6%±0.6%, 2.7%±1.7%, and 3.0Gy±0.8Gy respectively. For ipsilateral lung, V50Gy, V20Gy, V10Gy and V5Gy were 0.9%±1.1%, 34.3%±5.1%, 51.6%±6.3% and 64.1%±7.5% respectively. Conclusion: For left-sided PU patients with unusual anatomy, energy modulated electron CW irradiation technique can achieve heart sparing with acceptable lung dose.« less

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boehling, Nicholas S.; Grosshans, David R., E-mail: dgrossha@mdanderson.org; Bluett, Jaques B.

    Purpose: Cranial irradiation in pediatric patients is associated with serious long-term adverse effects. We sought to determine whether both three-dimensional conformal proton radiotherapy (3D-PRT) and intensity-modulated proton therapy (IMPT) compared with intensity-modulated radiotherapy (IMRT) decrease integral dose to brain areas known to harbor neuronal stem cells, major blood vessels, and other normal brain structures for pediatric patients with craniopharyngiomas. Methods and Materials: IMRT, forward planned, passive scattering proton, and IMPT plans were generated and optimized for 10 pediatric patients. The dose was 50.4 Gy (or cobalt Gy equivalent) delivered in 28 fractions with the requirement for planning target volume (PTV)more » coverage of 95% or better. Integral dose data were calculated from differential dose-volume histograms. Results: The PTV target coverage was adequate for all modalities. IMRT and IMPT yielded the most conformal plans in comparison to 3D-PRT. Compared with IMRT, 3D-PRT and IMPT plans had a relative reduction of integral dose to the hippocampus (3D-PRT, 20.4; IMPT, 51.3%{sup Asterisk-Operator }), dentate gyrus (27.3, 75.0%{sup Asterisk-Operator }), and subventricular zone (4.5, 57.8%{sup Asterisk-Operator }). Vascular organs at risk also had reduced integral dose with the use of proton therapy (anterior cerebral arteries, 33.3{sup Asterisk-Operator }, 100.0%{sup Asterisk-Operator }; middle cerebral arteries, 25.9%{sup Asterisk-Operator }, 100%{sup Asterisk-Operator }; anterior communicating arteries, 30.8{sup Asterisk-Operator }, 41.7%{sup Asterisk-Operator }; and carotid arteries, 51.5{sup Asterisk-Operator }, 77.6{sup Asterisk-Operator }). Relative reduction of integral dose to the infratentorial brain (190.7{sup Asterisk-Operator }, 109.7%{sup Asterisk-Operator }), supratentorial brain without PTV (9.6, 26.8%{sup Asterisk-Operator }), brainstem (45.6, 22.4%{sup Asterisk-Operator }), and whole brain without PTV (19.4{sup Asterisk-Operator }, 34.4%{sup Asterisk-Operator }) were recorded with the use of proton therapy. ({sup Asterisk-Operator }Differences were significant based on Friedman's test with Bonferroni-Dunn correction, {alpha} = 0.05) Conclusions: The current study found that proton therapy was able to avoid excess integral radiation dose to a variety of normal structures at all dose levels while maintaining equal target coverage. Future studies will examine the clinical benefits of these dosimetric advantages.« less

  12. Realistic respiratory motion margins for external beam partial breast irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conroy, Leigh; Quirk, Sarah; Department of Physics and Astronomy, University of Calgary, Calgary, Alberta T2N 1N4

    Purpose: Respiratory margins for partial breast irradiation (PBI) have been largely based on geometric observations, which may overestimate the margin required for dosimetric coverage. In this study, dosimetric population-based respiratory margins and margin formulas for external beam partial breast irradiation are determined. Methods: Volunteer respiratory data and anterior–posterior (AP) dose profiles from clinical treatment plans of 28 3D conformal radiotherapy (3DCRT) PBI patient plans were used to determine population-based respiratory margins. The peak-to-peak amplitudes (A) of realistic respiratory motion data from healthy volunteers were scaled from A = 1 to 10 mm to create respiratory motion probability density functions. Dosemore » profiles were convolved with the respiratory probability density functions to produce blurred dose profiles accounting for respiratory motion. The required margins were found by measuring the distance between the simulated treatment and original dose profiles at the 95% isodose level. Results: The symmetric dosimetric respiratory margins to cover 90%, 95%, and 100% of the simulated treatment population were 1.5, 2, and 4 mm, respectively. With patient set up at end exhale, the required margins were larger in the anterior direction than the posterior. For respiratory amplitudes less than 5 mm, the population-based margins can be expressed as a fraction of the extent of respiratory motion. The derived formulas in the anterior/posterior directions for 90%, 95%, and 100% simulated population coverage were 0.45A/0.25A, 0.50A/0.30A, and 0.70A/0.40A. The differences in formulas for different population coverage criteria demonstrate that respiratory trace shape and baseline drift characteristics affect individual respiratory margins even for the same average peak-to-peak amplitude. Conclusions: A methodology for determining population-based respiratory margins using real respiratory motion patterns and dose profiles in the AP direction was described. It was found that the currently used respiratory margin of 5 mm in partial breast irradiation may be overly conservative for many 3DCRT PBI patients. Amplitude alone was found to be insufficient to determine patient-specific margins: individual respiratory trace shape and baseline drift both contributed to the dosimetric target coverage. With respiratory coaching, individualized respiratory margins smaller than the full extent of motion could reduce planning target volumes while ensuring adequate coverage under respiratory motion.« less

  13. Assessment of on-time vaccination coverage in population subgroups: A record linkage cohort study.

    PubMed

    Moore, Hannah C; Fathima, Parveen; Gidding, Heather F; de Klerk, Nicholas; Liu, Bette; Sheppeard, Vicky; Effler, Paul V; Snelling, Thomas L; McIntyre, Peter; Blyth, Christopher C

    2018-05-31

    Reported infant vaccination coverage at age 12 months in Australia is >90%. On-time coverage of the 2-4-6 month schedule and coverage in specific populations is rarely reported. We conducted a population-based cohort study of 1.9 million Australian births, 1996-2012, combining individual birth and perinatal records with immunisation records through probabilistic linkage. We assessed on-time coverage across 13 demographic and perinatal characteristics of diphtheria-tetanus-pertussis vaccines (DTP) defined as vaccination 14 days prior to the scheduled due date, to 30 days afterwards. On-time DTP vaccination coverage in non-Aboriginal infants was 88.1% for the 2-month dose, 82.0% for 4-month dose, and 76.7% for 6-month dose; 3-dose coverage was 91.3% when assessed at 12 months. On-time DTP coverage for Aboriginal infants was 77.0%, 66.5%, and 61.0% for the 2-4-6 month dose; 3-dose coverage at 12 months was 79.3%. Appreciable differences in on-time coverage were observed across population subgroups. On-time coverage in non-Aboriginal infants born to mothers with ≥3 previous pregnancies was 62.5% for the 6-month dose (47.9% for Aboriginal infants); up to 23.5 percentage points lower than for first-borns. Infants born to mothers who smoked during pregnancy had coverage 8.7-10.3 percentage points lower than infants born to non-smoking mothers for the 4- and 6-month dose. A linear relationship was apparent between increasing socio-economic disadvantage and decreasing on-time coverage. On-time coverage of the 2-4-6 month schedule is only 50-60% across specific population subgroups representing a significant avoidable public health risk. Aboriginal infants, multiparous mothers, and those who are socio-economically disadvantaged are key groups most likely to benefit from targeted programs addressing vaccine timeliness. Copyright © 2018. Published by Elsevier Ltd.

  14. Dosimetric advantages of a clinical daily adaptive plan selection strategy compared with a non-adaptive strategy in cervical cancer radiation therapy.

    PubMed

    van de Schoot, Agustinus J A J; de Boer, Peter; Visser, Jorrit; Stalpers, Lukas J A; Rasch, Coen R N; Bel, Arjan

    2017-05-01

    Radiation therapy (RT) using a daily plan selection adaptive strategy can be applied to account for interfraction organ motion while limiting organ at risk dose. The aim of this study was to quantify the dosimetric consequences of daily plan selection compared with non-adaptive RT in cervical cancer. Ten consecutive patients who received pelvic irradiation, planning CTs (full and empty bladder), weekly post-fraction CTs and pre-fraction CBCTs were included. Non-adaptive plans were generated based on the PTV defined using the full bladder planning CT. For the adaptive strategy, multiple PTVs were created based on both planning CTs by ITVs of the primary CTVs (i.e., GTV, cervix, corpus-uterus and upper part of the vagina) and corresponding library plans were generated. Daily CBCTs were rigidly aligned to the full bladder planning CT for plan selection. For daily plan recalculation, selected CTs based on initial similarity were deformably registered to CBCTs. Differences in daily target coverage (D 98%  > 95%) and in V 0.5Gy , V 1.5Gy , V 2Gy , D 50% and D 2% for rectum, bladder and bowel were assessed. Non-adaptive RT showed inadequate primary CTV coverage in 17% of the daily fractions. Plan selection compensated for anatomical changes and improved primary CTV coverage significantly (p < 0.01) to 98%. Compared with non-adaptive RT, plan selection decreased the fraction dose to rectum and bowel indicated by significant (p < 0.01) improvements for daily V 0.5Gy , V 1.5Gy , V 2Gy , D 50% and D 2% . However, daily plan selection significantly increased the bladder V 1.5Gy , V 2Gy , D 50% and D 2% . In cervical cancer RT, a non-adaptive strategy led to inadequate target coverage for individual patients. Daily plan selection corrected for day-to-day anatomical variations and resulted in adequate target coverage in all fractions. The dose to bowel and rectum was decreased significantly when applying adaptive RT.

  15. Comparison of treatment plans: a retrospective study by the method of radiobiological evaluation

    NASA Astrophysics Data System (ADS)

    Puzhakkal, Niyas; Kallikuzhiyil Kochunny, Abdullah; Manthala Padannayil, Noufal; Singh, Navin; Elavan Chalil, Jumanath; Kulangarakath Umer, Jamshad

    2016-09-01

    There are many situations in radiotherapy where multiple treatment plans need to be compared for selection of an optimal plan. In this study we performed the radiobiological method of plan evaluation to verify the treatment plan comparison procedure of our clinical practice. We estimated and correlated various radiobiological dose indices with physical dose metrics for a total of 30 patients representing typical cases of head and neck, prostate and brain tumors. Three sets of plans along with a clinically approved plan (final plan) treated by either Intensity Modulated Radiation Therapy (IMRT) or Rapid Arc (RA) techniques were considered. The study yielded improved target coverage for final plans, however, no appreciable differences in doses and the complication probabilities of organs at risk were noticed. Even though all four plans showed adequate dose distributions, from dosimetric point of view, the final plan had more acceptable dose distribution. The estimated biological outcome and dose volume histogram data showed least differences between plans for IMRT when compared to RA. Our retrospective study based on 120 plans, validated the radiobiological method of plan evaluation. The tumor cure or normal tissue complication probabilities were found to be correlated with the corresponding physical dose indices.

  16. SU-F-T-27: A Comparative Case Study Among Four Modalities for the Superficial Treatment of Squamous Cell Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ashenafi, M; Koch, N; Peng, J

    Purpose: We performed a comparative planning study among High Dose Rate (HDR) brachytherapy, superficial electrons, Volume Modulated Arc Therapy (VMAT), and Helical IMRT (Tomotherapy) for squamous cell carcinoma of the abdominal wall with consideration for the underlining bowel. Methods: A 69-year old female presented with squamous cell carcinoma protruding 8mm beyond the anterior skin surface of the midabdomen was considered for treatment. The patient had a ventral hernia which resulted in the reduction of the abdominal wall thickness and the adjacent small bowel being the dose limiting structure. Four plans were generated using different treatment modalities: a) an enface electronmore » field (eMC, Eclipse v. 11), b) Tomotherapy (HI-Art II v.5.0.5), c) VMAT (Acuros, Eclipse v. 11), and d) HDR using a Freiburg applicator (Oncentra v. 4.3). The following plan objectives were used for all four plans: for the CTV target, V90% ≥90% (61.8Gy2/2).For the small bowel, D0.1cc < 56.2 Gy2/2 was a hard constraint and expressed as a percentage of the prescription for comparison to demonstrate the dose fall-off achieved among the modalities.For HDR, V200% <0.1cc was an additional constraint. Multiple dosimetric parameters, including those listed above, were compared among the four modalities. Results: The HDR plan showed comparable target coverage compared to the Tomotherapy plan and better coverage compared to the electron plan. Small bowel doses (D0.1cc) were lower in HDR plan compared to Tomotherapy, electron, & VMAT plans (88.8%, 89.6%, 90.9%, & 96.6%). Integral dose to the whole body (V5%) was much higher for HDR, VMAT, and Tomotherapy when compared to electron plan by factors of seven, eight, and ten, respectively. After reviewing all treatment modalities, the physician selected HDR owing to better control of the small bowel dose while maintaining adequate target coverage. Conclusion: This case study demonstrated HDR can successfully treat superficial lesions with superior sparing of underlying structures.« less

  17. [First confirmed case of laryngeal diphtheria in Djibouti].

    PubMed

    Koeck, J L; Merle, C; Bimet, F; Kiredjian, M; Goullin, B; Teyssou, R

    2000-01-01

    The first bacteriologically confirmed case of laryngeal diphtheria in Djibouti was reported in 1998. It involved a three-year-old native-born infant who had been vaccinated during the first year of life with three doses of a combined vaccine against diphtheria, tetanus, poliomyelitis, and pertussis. A rapid clinical improvement was observed under erythromycin treatment. Other cases of laryngeal diphtheria have been observed. It is important to reverse decreasing vaccinal coverage in Djibouti and to warn incoming travelers of the need to be adequate immunized against diphtheria. Enhanced epidemiologic surveillance of this disease is also needed.

  18. Household Coverage with Adequately Iodized Salt Varies Greatly between Countries and by Residence Type and Socioeconomic Status within Countries: Results from 10 National Coverage Surveys123

    PubMed Central

    Knowles, Jacky M; Garrett, Greg S; Gorstein, Jonathan; Kupka, Roland; Situma, Ruth; Yadav, Kapil; Yusufali, Rizwan; Pandav, Chandrakant; Aaron, Grant J

    2017-01-01

    Background: Household coverage with iodized salt was assessed in 10 countries that implemented Universal Salt Iodization (USI). Objective: The objective of this paper was to summarize household coverage data for iodized salt, including the relation between coverage and residence type and socioeconomic status (SES). Methods: A review was conducted of results from cross-sectional multistage household cluster surveys with the use of stratified probability proportional to size design in Bangladesh, Ethiopia, Ghana, India, Indonesia, Niger, the Philippines, Senegal, Tanzania, and Uganda. Salt iodine content was assessed with quantitative methods in all cases. The primary indicator of coverage was percentage of households that used adequately iodized salt, with an additional indicator for salt with some added iodine. Indicators of risk were SES and residence type. We used 95% CIs to determine significant differences in coverage. Results: National household coverage of adequately iodized salt varied from 6.2% in Niger to 97.0% in Uganda. For salt with some added iodine, coverage varied from 52.4% in the Philippines to 99.5% in Uganda. Coverage with adequately iodized salt was significantly higher in urban than in rural households in Bangladesh (68.9% compared with 44.3%, respectively), India (86.4% compared with 69.8%, respectively), Indonesia (59.3% compared with 51.4%, respectively), the Philippines (31.5% compared with 20.2%, respectively), Senegal (53.3% compared with 19.0%, respectively), and Tanzania (89.2% compared with 57.6%, respectively). In 7 of 8 countries with data, household coverage of adequately iodized salt was significantly higher in high- than in low-SES households in Bangladesh (58.8% compared with 39.7%, respectively), Ghana (36.2% compared with 21.5%, respectively), India (80.6% compared with 70.5%, respectively), Indonesia (59.9% compared with 45.6%, respectively), the Philippines (39.4% compared with 17.3%, respectively), Senegal (50.7% compared with 27.6%, respectively) and Tanzania (80.9% compared with 51.3%, respectively). Conclusions: Uganda has achieved USI. In other countries, access to iodized salt is inequitable. Quality control and regulatory enforcement of salt iodization remain challenging. Notable progress toward USI has been made in Ethiopia and India. Assessing progress toward USI only through household salt does not account for potentially iodized salt consumed through processed foods. PMID:28404840

  19. Household Coverage with Adequately Iodized Salt Varies Greatly between Countries and by Residence Type and Socioeconomic Status within Countries: Results from 10 National Coverage Surveys.

    PubMed

    Knowles, Jacky M; Garrett, Greg S; Gorstein, Jonathan; Kupka, Roland; Situma, Ruth; Yadav, Kapil; Yusufali, Rizwan; Pandav, Chandrakant; Aaron, Grant J

    2017-05-01

    Background: Household coverage with iodized salt was assessed in 10 countries that implemented Universal Salt Iodization (USI). Objective: The objective of this paper was to summarize household coverage data for iodized salt, including the relation between coverage and residence type and socioeconomic status (SES). Methods: A review was conducted of results from cross-sectional multistage household cluster surveys with the use of stratified probability proportional to size design in Bangladesh, Ethiopia, Ghana, India, Indonesia, Niger, the Philippines, Senegal, Tanzania, and Uganda. Salt iodine content was assessed with quantitative methods in all cases. The primary indicator of coverage was percentage of households that used adequately iodized salt, with an additional indicator for salt with some added iodine. Indicators of risk were SES and residence type. We used 95% CIs to determine significant differences in coverage. Results: National household coverage of adequately iodized salt varied from 6.2% in Niger to 97.0% in Uganda. For salt with some added iodine, coverage varied from 52.4% in the Philippines to 99.5% in Uganda. Coverage with adequately iodized salt was significantly higher in urban than in rural households in Bangladesh (68.9% compared with 44.3%, respectively), India (86.4% compared with 69.8%, respectively), Indonesia (59.3% compared with 51.4%, respectively), the Philippines (31.5% compared with 20.2%, respectively), Senegal (53.3% compared with 19.0%, respectively), and Tanzania (89.2% compared with 57.6%, respectively). In 7 of 8 countries with data, household coverage of adequately iodized salt was significantly higher in high- than in low-SES households in Bangladesh (58.8% compared with 39.7%, respectively), Ghana (36.2% compared with 21.5%, respectively), India (80.6% compared with 70.5%, respectively), Indonesia (59.9% compared with 45.6%, respectively), the Philippines (39.4% compared with 17.3%, respectively), Senegal (50.7% compared with 27.6%, respectively) and Tanzania (80.9% compared with 51.3%, respectively). Conclusions: Uganda has achieved USI. In other countries, access to iodized salt is inequitable. Quality control and regulatory enforcement of salt iodization remain challenging. Notable progress toward USI has been made in Ethiopia and India. Assessing progress toward USI only through household salt does not account for potentially iodized salt consumed through processed foods.

  20. Routine Vaccination Coverage in Northern Nigeria: Results from 40 District-Level Cluster Surveys, 2014-2015

    PubMed Central

    Ogbuanu, Ikechukwu U.; Adegoke, Oluwasegun J.; Scobie, Heather M.; Uba, Belinda V.; Wannemuehler, Kathleen A.; Ruiz, Alicia; Elmousaad, Hashim; Ohuabunwo, Chima J.; Mustafa, Mahmud; Nguku, Patrick; Waziri, Ndadilnasiya Endie; Vertefeuille, John F.

    2016-01-01

    Background Despite recent success towards controlling poliovirus transmission, Nigeria has struggled to achieve uniformly high routine vaccination coverage. A lack of reliable vaccination coverage data at the operational level makes it challenging to target program improvement. To reliably estimate vaccination coverage, we conducted district-level vaccine coverage surveys using a pre-existing infrastructure of polio technical staff in northern Nigeria. Methods Household-level cluster surveys were conducted in 40 polio high risk districts of Nigeria during 2014–2015. Global positioning system technology and intensive supervision by a pool of qualified technical staff were used to ensure high survey quality. Vaccination status of children aged 12–23 months was documented based on vaccination card or caretaker’s recall. District-level coverage estimates were calculated using survey methods. Results Data from 7,815 children across 40 districts were analyzed. District-level coverage with the third dose of diphtheria-pertussis-tetanus vaccine (DPT3) ranged widely from 1–63%, with all districts having DPT3 coverage below the target of 80%. Median coverage across all districts for each of eight vaccine doses (1 Bacille Calmette-Guérin dose, 3 DPT doses, 3 oral poliovirus vaccine doses, and 1 measles vaccine dose) was <50%. DPT3 coverage by survey was substantially lower (range: 28%–139%) than the 2013 administrative coverage reported among children aged <12 months. Common reported reasons for non-vaccination included lack of knowledge about vaccines and vaccination services (50%) and factors related to access to routine immunization services (15%). Conclusions Survey results highlighted vaccine coverage gaps that were systematically underestimated by administrative reporting across 40 polio high risk districts in northern Nigeria. Given the limitations of administrative coverage data, our approach to conducting quality district-level coverage surveys and providing data to assess and remediate issues contributing to poor vaccination coverage could serve as an example in countries with sub-optimal vaccination coverage, similar to Nigeria. PMID:27936077

  1. Routine Vaccination Coverage in Northern Nigeria: Results from 40 District-Level Cluster Surveys, 2014-2015.

    PubMed

    Gunnala, Rajni; Ogbuanu, Ikechukwu U; Adegoke, Oluwasegun J; Scobie, Heather M; Uba, Belinda V; Wannemuehler, Kathleen A; Ruiz, Alicia; Elmousaad, Hashim; Ohuabunwo, Chima J; Mustafa, Mahmud; Nguku, Patrick; Waziri, Ndadilnasiya Endie; Vertefeuille, John F

    2016-01-01

    Despite recent success towards controlling poliovirus transmission, Nigeria has struggled to achieve uniformly high routine vaccination coverage. A lack of reliable vaccination coverage data at the operational level makes it challenging to target program improvement. To reliably estimate vaccination coverage, we conducted district-level vaccine coverage surveys using a pre-existing infrastructure of polio technical staff in northern Nigeria. Household-level cluster surveys were conducted in 40 polio high risk districts of Nigeria during 2014-2015. Global positioning system technology and intensive supervision by a pool of qualified technical staff were used to ensure high survey quality. Vaccination status of children aged 12-23 months was documented based on vaccination card or caretaker's recall. District-level coverage estimates were calculated using survey methods. Data from 7,815 children across 40 districts were analyzed. District-level coverage with the third dose of diphtheria-pertussis-tetanus vaccine (DPT3) ranged widely from 1-63%, with all districts having DPT3 coverage below the target of 80%. Median coverage across all districts for each of eight vaccine doses (1 Bacille Calmette-Guérin dose, 3 DPT doses, 3 oral poliovirus vaccine doses, and 1 measles vaccine dose) was <50%. DPT3 coverage by survey was substantially lower (range: 28%-139%) than the 2013 administrative coverage reported among children aged <12 months. Common reported reasons for non-vaccination included lack of knowledge about vaccines and vaccination services (50%) and factors related to access to routine immunization services (15%). Survey results highlighted vaccine coverage gaps that were systematically underestimated by administrative reporting across 40 polio high risk districts in northern Nigeria. Given the limitations of administrative coverage data, our approach to conducting quality district-level coverage surveys and providing data to assess and remediate issues contributing to poor vaccination coverage could serve as an example in countries with sub-optimal vaccination coverage, similar to Nigeria.

  2. SU-E-T-620: Dosimetric Compliance Study for a New Prostate Protocol of Combined High Dose Rate Brachytherapy and Stereotactic Body Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peng, C; Giaddui, T; Den, R

    2014-06-15

    Purpose: To investigate the adherence of treatment plans of prostate cancer patients with the dosimetric compliance criteria of the new in house phase I trial of high dose rate (HDR) brachytherapy combined with stereotactic body radiotherapy (SBRT) for intermediate risk prostate cancer patients. Methods: Ten prostate cancer patients were treated using this trial. They received one fraction of HDR to 15Gy, followed by external beam(EB) boost of 3.2Gy(Level 1, five patients) or 3.94Gy(level 2, five patients) per fraction for 10 or 7 fractions, respectively, both equivalent to EB treatments of 113.5Gy in 2Gy fractions. The EB plans were either IMRTmore » or VMAT plans. DVH analysis was performed to verify the adherence of treatment plans to the dosimetric criteria of the trial. Results: For Level 1 patients, target coverage were adequate, with CTV V32Gy(%) of 99.0±1.0 (mean ± 1 standard deviation), and PTV V31Gy(%) of 99.6±0.3. PTV V32.9Gy(%) is 1.4±3.1 and PTVmax is 32.9±0.2Gy. Rectum, bladder and femoral heads sparing were well within protocol criteria. For Level 2 patients, CTV V27.6Gy(%) is 98.7±1.8; PTV V26.7Gy(%) is 99.0±1.4. PTV V28.4Gy(%) is 1.3±1.4, with three patients having minor deviation from protocol. Again critical structures were spared compliant to the protocol. The analysis of HDR plans show similar results, with adequate dose coverage to the prostate and sparing of critical structures including urethra and rectum. V100(%) and V90(%) of prostate are 96.0±1.1 and 98.9±0.5. Urethra D10(%) is 113.1±2.9. Rectum V80(cc) is 1.4±0.5. Hotspot in prostate is substantially higher than what the protocol specifies. But the criteria for hotspot are only guidelines, serving to lower the dose to urethra . Conclusion: This new high biological equivalent dose prostate trial has been carried out successfully for ten patients. Based on dosimetric analysis, all HDR and external plans were compliant to the protocol criteria, with only minor deviations.« less

  3. Vaccination coverage among foreign-born and U.S.-born adolescents in the United States: Successes and gaps - National Immunization Survey-Teen, 2012-2014.

    PubMed

    Healy, Jessica; Rodriguez-Lainz, Alfonso; Elam-Evans, Laurie D; Hill, Holly A; Reagan-Steiner, Sarah; Yankey, David

    2018-03-20

    An overall increase has been reported in vaccination rates among adolescents during the past decade. Studies of vaccination coverage have shown disparities when comparing foreign-born and U.S.-born populations among children and adults; however, limited information is available concerning potential disparities in adolescents. The National Immunization Survey-Teen is a random-digit-dialed telephone survey of caregivers of adolescents aged 13-17 years, followed by a mail survey to vaccination providers that is used to estimate vaccination coverage among the U.S. population of adolescents. Using the National Immunization Survey-Teen data, we assessed vaccination coverage during 2012-2014 among adolescents for routinely recommended vaccines for this age group (≥1 dose tetanus and diphtheria toxoids and acellular pertussis [Tdap] vaccine, ≥1 dose quadrivalent meningococcal conjugate [MenACWY] vaccine, ≥3 doses human papillomavirus [HPV] vaccine) and for routine childhood vaccination catch-up doses (≥2 doses measles, mumps, and rubella [MMR] vaccine, ≥2 doses varicella vaccine, and ≥3 doses hepatitis B [HepB] vaccine). Vaccination coverage prevalence and vaccination prevalence ratios were estimated. Of the 58,090 respondents included, 3.3% were foreign-born adolescents. Significant differences were observed between foreign-born and U.S.-born adolescents for insurance status, income-to-poverty ratio, education, interview language, and household size. Foreign-born adolescents had significantly lower unadjusted vaccination coverage for HepB (89% vs. 93%), and higher coverage for the recommended ≥3 doses of HPV vaccine among males, compared with U.S.-born adolescents (22% vs. 14%). Adjustment for demographic and socioeconomic factors accounted for the disparity in HPV but not HepB vaccination coverage. We report comparable unadjusted vaccination coverage among foreign-born and U.S.-born adolescents for Tdap, MenACWY, MMR, ≥2 varicella. Although coverage was high for HepB vaccine, it was significantly lower among foreign-born adolescents, compared with U.S.-born adolescents. HPV and ≥2-dose varicella vaccination coverage were low among both groups. Published by Elsevier Ltd.

  4. Vaccination Coverage Disparities Between Foreign-Born and U.S.-Born Children Aged 19-35 Months, United States, 2010-2012.

    PubMed

    Varan, Aiden K; Rodriguez-Lainz, Alfonso; Hill, Holly A; Elam-Evans, Laurie D; Yankey, David; Li, Qian

    2017-08-01

    Healthy People 2020 targets high vaccination coverage among children. Although reductions in coverage disparities by race/ethnicity have been described, data by nativity are limited. The National Immunization Survey is a random-digit-dialed telephone survey that estimates vaccination coverage among U.S. children aged 19-35 months. We assessed coverage among 52,441 children from pooled 2010-2012 data for individual vaccines and the combined 4:3:1:3*:3:1:4 series (which includes ≥4 doses of diphtheria, tetanus, and acellular pertussis vaccine/diphtheria and tetanus toxoids vaccine/diphtheria, tetanus toxoids, and pertussis vaccine, ≥3 doses of poliovirus vaccine, ≥1 dose of measles-containing vaccine, ≥3 or ≥4 doses of Haemophilus influenzae type b vaccine (depending on product type of vaccine; denoted as 3* in the series name), ≥3 doses of hepatitis B vaccine, ≥1 dose of varicella vaccine, and ≥4 doses of pneumococcal conjugate vaccine). Coverage estimates controlling for sociodemographic factors and multivariable logistic regression modeling for 4:3:1:3*:3:1:4 series completion are presented. Significantly lower coverage among foreign-born children was detected for DTaP, hepatitis A, hepatitis B, Hib, pneumococcal conjugate, and rotavirus vaccines, and for the combined series. Series completion disparities persisted after control for demographic, access-to-care, poverty, and language effects. Substantial and potentially widening disparities in vaccination coverage exist among foreign-born children. Improved immunization strategies targeting this population and continued vaccination coverage monitoring by nativity are needed.

  5. Dosimetric comparison between intra-cavitary breast brachytherapy techniques for accelerated partial breast irradiation and a novel stereotactic radiotherapy device for breast cancer: GammaPod™

    NASA Astrophysics Data System (ADS)

    Ödén, Jakob; Toma-Dasu, Iuliana; Yu, Cedric X.; Feigenberg, Steven J.; Regine, William F.; Mutaf, Yildirim D.

    2013-07-01

    The GammaPod™ device, manufactured by Xcision Medical Systems, is a novel stereotactic breast irradiation device. It consists of a hemispherical source carrier containing 36 Cobalt-60 sources, a tungsten collimator with two built-in collimation sizes, a dynamically controlled patient support table and a breast immobilization cup also functioning as the stereotactic frame for the patient. The dosimetric output of the GammaPod™ was modelled using a Monte Carlo based treatment planning system. For the comparison, three-dimensional (3D) models of commonly used intra-cavitary breast brachytherapy techniques utilizing single lumen and multi-lumen balloon as well as peripheral catheter multi-lumen implant devices were created and corresponding 3D dose calculations were performed using the American Association of Physicists in Medicine Task Group-43 formalism. Dose distributions for clinically relevant target volumes were optimized using dosimetric goals set forth in the National Surgical Adjuvant Breast and Bowel Project Protocol B-39. For clinical scenarios assuming similar target sizes and proximity to critical organs, dose coverage, dose fall-off profiles beyond the target and skin doses at given distances beyond the target were calculated for GammaPod™ and compared with the doses achievable by the brachytherapy techniques. The dosimetric goals within the protocol guidelines were fulfilled for all target sizes and irradiation techniques. For central targets, at small distances from the target edge (up to approximately 1 cm) the brachytherapy techniques generally have a steeper dose fall-off gradient compared to GammaPod™ and at longer distances (more than about 1 cm) the relation is generally observed to be opposite. For targets close to the skin, the relative skin doses were considerably lower for GammaPod™ than for any of the brachytherapy techniques. In conclusion, GammaPod™ allows adequate and more uniform dose coverage to centrally and peripherally located targets with an acceptable dose fall-off and lower relative skin dose than the brachytherapy techniques considered in this study.

  6. A Performance Analysis of Public Expenditure on Maternal Health in Mexico.

    PubMed

    Servan-Mori, Edson; Avila-Burgos, Leticia; Nigenda, Gustavo; Lozano, Rafael

    2016-01-01

    We explore the relationship between public expenditure, coverage of adequate ANC (including timing, frequent and content), and the maternal mortality ratio--adjusted by coverage of adequate ANC--observed in Mexico in 2012 at the State level. Additionally, we examine the inequalities and concentration of public expenditure between populations with and without Social Security. Results suggest that in the 2003-2011 period, the public expenditure gap between women with and without Social Security decreased 74%, however, the distribution is less equitable among women without Social Security, across the States. Despite high levels of coverage on each dimension of ANC explored, coverage of adequate ANC was lower among Social Security than non-Social Security women. This variability results in differences up to 1.5 times in State-adjusted maternal mortality rate at the same level of expense and maternal mortality rate, respectively. The increase in the economic resources is only a necessary condition for achieving improved health outcomes. Providing adequate health services and achieving efficient, effective and transparent use of resources in health, are critical elements for health systems performance. The attainment of universal effective coverage of maternal health and reducing maternal mortality in Mexico, requires the adjustment of policy innovations including the rules of allocation and execution of health resources. Health policies should be designed on a more holistic view promoting a balance between accessibility, effective implementation and rigorous stewardship.

  7. A Performance Analysis of Public Expenditure on Maternal Health in Mexico

    PubMed Central

    Servan-Mori, Edson; Avila-Burgos, Leticia; Nigenda, Gustavo; Lozano, Rafael

    2016-01-01

    We explore the relationship between public expenditure, coverage of adequate ANC (including timing, frequent and content), and the maternal mortality ratio -adjusted by coverage of adequate ANC- observed in Mexico in 2012 at the State level. Additionally, we examine the inequalities and concentration of public expenditure between populations with and without Social Security. Results suggest that in the 2003–2011 period, the public expenditure gap between women with and without Social Security decreased 74%, however, the distribution is less equitable among women without Social Security, across the States. Despite high levels of coverage on each dimension of ANC explored, coverage of adequate ANC was lower among Social Security than non-Social Security women. This variability results in differences up to 1.5 times in State-adjusted maternal mortality rate at the same level of expense and maternal mortality rate, respectively. The increase in the economic resources is only a necessary condition for achieving improved health outcomes. Providing adequate health services and achieving efficient, effective and transparent use of resources in health, are critical elements for health systems performance. The attainment of universal effective coverage of maternal health and reducing maternal mortality in Mexico, requires the adjustment of policy innovations including the rules of allocation and execution of health resources. Health policies should be designed on a more holistic view promoting a balance between accessibility, effective implementation and rigorous stewardship. PMID:27043819

  8. [What are the pharmacological options for treating resistant hypertension?

    PubMed

    Martell-Claros, N; Abad-Cardiel, M

    2017-01-01

    When treating a patient with resistant hypertension therapy should be optimize in order to prescribe three antihypertensive drugs at full doses, being powerful drugs, having 24-hour coverage, and showing synergistic effects. Diuretic therapy is of special relevance. The fourth drug should be an aldosterone antagonists. In the case of intolerance, or when control is not achieved, drugs from other type of antihypertensive drugs should be, sometimes allowing adequate blood pressure control. Copyright © 2017 Sociedad Española de Hipertension-Liga Española para la Lucha de la Hipertensión Arterial (SEH-LELHA). Publicado por Elsevier España, S.L.U. All rights reserved.

  9. National, State, and Selected Local Area Vaccination Coverage Among Children Aged 19-35 Months - United States, 2014.

    PubMed

    Hill, Holly A; Elam-Evans, Laurie D; Yankey, David; Singleton, James A; Kolasa, Maureen

    2015-08-28

    The reduction in morbidity and mortality associated with vaccine-preventable diseases in the United States has been described as one of the 10 greatest public health achievements of the first decade of the 21st century. A recent analysis concluded that routine childhood vaccination will prevent 322 million cases of disease and about 732,000 early deaths among children born during 1994-2013, for a net societal cost savings of $1.38 trillion. The National Immunization Survey (NIS) has monitored vaccination coverage among U.S. children aged 19-35 months since 1994. This report presents national, regional, state, and selected local area vaccination coverage estimates for children born from January 2011 through May 2013, based on data from the 2014 NIS. For most vaccinations, there was no significant change in coverage between 2013 and 2014. The exception was hepatitis A vaccine (HepA), for which increases were observed in coverage with both ≥1 and ≥2 doses. As in previous years, <1% of children received no vaccinations. National coverage estimates indicate that the Healthy People 2020 target* of 90% was met for ≥3 doses of poliovirus vaccine (93.3%), ≥1 dose of measles, mumps, and rubella vaccine (MMR) (91.5%), ≥3 doses of hepatitis B vaccine (HepB) (91.6%), and ≥1 dose of varicella vaccine (91.0%). Coverage was below target for ≥4 doses of diphtheria, tetanus, and acellular pertussis vaccine (DTaP), the full series of Haemophilus influenzae type b (Hib) vaccine, hepatitis B (HepB) birth dose,† ≥4 doses pneumococcal conjugate vaccine (PCV), ≥2 doses of HepA, the full series of rotavirus vaccine, and the combined vaccine series.§ Examination of coverage by child's race/ethnicity revealed lower estimated coverage among non-Hispanic black children compared with non-Hispanic white children for several vaccinations, including DTaP, the full series of Hib, PCV, rotavirus vaccine, and the combined series. Children from households classified as below the federal poverty level had lower estimated coverage for almost all of the vaccinations assessed, compared with children living at or above the poverty level. Significant variation in coverage by state¶ was observed for several vaccinations, including HepB birth dose, HepA, and rotavirus. High vaccination coverage must be maintained across geographic and sociodemographic groups if progress in reducing the impact of vaccine-preventable diseases is to be sustained.

  10. Progress toward measles preelimination--African Region, 2011-2012.

    PubMed

    Masresha, Balcha G; Kaiser, Reinhard; Eshetu, Messeret; Katsande, Reggis; Luce, Richard; Fall, Amadou; Dosseh, Annick R G A; Naouri, Boubker; Byabamazima, Charles R; Perry, Robert; Dabbagh, Alya J; Strebel, Peter; Kretsinger, Katrina; Goodson, James L; Nshimirimana, Deo

    2014-04-04

    In 2008, the 46 member states of the World Health Organization (WHO) African Region (AFR) adopted a measles preelimination goal to reach by the end of 2012 with the following targets: 1) >98% reduction in estimated regional measles mortality compared with 2000, 2) annual measles incidence of fewer than five reported cases per million population nationally, 3) >90% national first dose of measles-containing vaccine (MCV1) coverage and >80% MCV1 coverage in all districts, and 4) >95% MCV coverage in all districts by supplementary immunization activities (SIAs). Surveillance performance objectives were to report two or more cases of nonmeasles febrile rash illness per 100,000 population, one or more suspected measles cases investigated with blood specimens in ≥80% of districts, and 100% completeness of surveillance reporting from all districts. This report updates previous reports and describes progress toward the measles preelimination goal during 2011-2012. In 2012, 13 (28%) member states had >90% MCV1 coverage, and three (7%) reported >90% MCV1 coverage nationally and >80% coverage in all districts. During 2011-2012, four (15%) of 27 SIAs with available information met the target of >95% coverage in all districts. In 2012, 16 of 43 (37%) member states met the incidence target of fewer than five cases per million, and 19 of 43 (44%) met both surveillance performance targets. In 2011, the WHO Regional Committee for AFR established a goal to achieve measles elimination by 2020. To achieve this goal, intensified efforts to identify and close population immunity gaps and improve surveillance quality are needed, as well as committed leadership and ownership of the measles elimination activities and mobilization of adequate resources to complement funding from global partners.

  11. Association of Health Insurance Status and Vaccination Coverage among Adolescents 13-17 Years of Age.

    PubMed

    Lu, Peng-Jun; Yankey, David; Jeyarajah, Jenny; O'Halloran, Alissa; Fredua, Benjamin; Elam-Evans, Laurie D; Reagan-Steiner, Sarah

    2018-04-01

    To assess selected vaccination coverage among adolescents by health insurance status and other access-to-care characteristics. The 2015 National Immunization Survey-Teen data were used to assess vaccination coverage disparities among adolescents by health insurance status and other access-to-care variables. Multivariable logistic regression analysis and a predictive marginal modeling were conducted to evaluate associations between health insurance status and vaccination coverage. Overall, vaccination coverage was significantly lower among uninsured compared with insured adolescents for all vaccines assessed for except ≥3 doses of human papillomavirus vaccine (HPV) among male adolescents. Among adolescents 13-17 years of age, vaccination of uninsured compared with insured adolescents, respectively, for tetanus toxoid, reduced content diphtheria toxoid, and acellular pertussis vaccine was 77.4% vs 86.8%; for ≥1 dose of meningococcal conjugate vaccine was 72.9% vs 81.7%; for ≥1 dose of HPV was 38.8% vs 50.2% among male and 42.9% vs 63.8% among female adolescents; for 3 doses of HPV was 24.9% vs 42.8% among female adolescents. In addition, vaccination coverage differed by the following: type of insurance among insured adolescents, having a well-child visit at 11-12 years of age, and number of healthcare provider contacts in the past year. Uninsured were less likely than insured adolescents to be vaccinated for HPV (female: ≥1 dose and 3 doses; and male: ≥1 doses) after adjusting for confounding variables. Overall, vaccination coverage was lower among uninsured adolescents. HPV vaccination coverage was lower than tetanus toxoid, reduced content diphtheria toxoid, and acellular pertussis vaccine Tdap and meningococcal conjugate vaccine in both insured and uninsured adolescents. Wider implementation of effective evidence-based strategies is needed to help improve vaccination coverage among adolescents, particularly for those who are uninsured. Limitation of current federally funded vaccination programs or access to healthcare would be expected to erode vaccine coverage of adolescents. Published by Elsevier Inc.

  12. NSW annual immunisation coverage report, 2011.

    PubMed

    Hull, Brynley; Dey, Aditi; Campbell-Lloyd, Sue; Menzies, Robert I; McIntyre, Peter B

    2012-12-01

    This annual report, the third in the series, documents trends in immunisation coverage in NSW for children, adolescents and the elderly, to the end of 2011. Data from the Australian Childhood Immunisation Register, the NSW School Immunisation Program and the NSW Population Health Survey were used to calculate various measures of population coverage. During 2011, greater than 90% coverage was maintained for children at 12 and 24 months of age. For children at 5 years of age the improvement seen in 2010 was sustained, with coverage at or near 90%. For adolescents, there was improved coverage for all doses of human papillomavirus vaccine, both doses of hepatitis B vaccine, varicella vaccine and the dose of diphtheria, tetanus and acellular pertussis given to school attendees in Years 7 and 10. Pneumococcal vaccination coverage in the elderly has been steadily rising, although it has remained lower than the influenza coverage estimates. This report provides trends in immunisation coverage in NSW across the age spectrum. The inclusion of coverage estimates for the pneumococcal conjugate, varicella and meningococcal C vaccines in the official coverage assessments for 'fully immunised' in 2013 is a welcome initiative.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moteabbed, M; Depauw, N; Kooy, H

    Purpose: To investigate the dosimetric benefits of pencil beam scanning (PBS) compared with passive scattered (PS) proton therapy for treatment of pediatric head&neck patients as a function of the PBS spot size and explore the advantages of using apertures in PBS. Methods: Ten pediatric patients with head&neck cancers treated by PS proton therapy at our institution were retrospectively selected. The histologies included rhabdomyosarcoma, ependymoma, astrocytoma, craniopharyngioma and germinoma. The prescribed dose ranged from 36 to 54 Gy(RBE). Five PBS plans were created for each patient using variable spot size (average sigma at isocenter) and choice of beam specific apertures: (1)more » 10mm spots, (2) 10mm spots with apertures, (3) 6mm spots, (4) 6mm spots with apertures, and (5) 3mm spots. The plans were optimized for intensity modulated proton therapy (IMPT) with no single beam uniformity constraints. Dose volume indices as well as equivalent uniform dose (EUD) were compared between PS and PBS plans. Results: Although target coverage was clinically adequate for all cases, the plans with largest (10mm) spots provide inferior quality compared with PS in terms of dose to organs-at-risk (OAR). However, adding apertures to these plans ensured lower OAR dose than PS. The average EUD difference between PBS and PS plans over all patients and organs at risk were (1) 2.5%, (2) −5.1%, (3) -5%, (4) −7.8%, and (5) −9.5%. As the spot size decreased, more conformal plans were achieved that offered similar target coverage but lower dose to the neighboring healthy organs, while alleviating the need for using apertures. Conclusion: The application of PBS does not always translate to better plan qualities compared to PS depending on the available beam spot size. We recommend that institutions with spot size larger than ∼6mm at isocenter consider using apertures to guarantee clinically comparable or superior dosimetric efficacy to PS treatments.« less

  14. Performance of rapid test kits to assess household coverage of iodized salt.

    PubMed

    Gorstein, Jonathan; van der Haar, Frits; Codling, Karen; Houston, Robin; Knowles, Jacky; Timmer, Arnold

    2016-10-01

    The main indicator adopted to track universal salt iodization has been the coverage of adequately iodized salt in households. Rapid test kits (RTK) have been included in household surveys to test the iodine content in salt. However, laboratory studies of their performance have concluded that RTK are reliable only to distinguish between the presence and absence of iodine in salt, but not to determine whether salt is adequately iodized. The aim of the current paper was to examine the performance of RTK under field conditions and to recommend their most appropriate use in household surveys. Standard performance characteristics of the ability of RTK to detect the iodine content in salt at 0 mg/kg (salt with no iodine), 5 mg/kg (salt with any added iodine) and 15 mg/kg ('adequately' iodized salt) were calculated. Our analysis employed the agreement rate (AR) as a preferred metric of RTK performance. Setting/Subjects Twenty-five data sets from eighteen population surveys which assessed household iodized salt by both the RTK and a quantitative method (i.e. titration or WYD Checker) were obtained from Asian (nineteen data sets), African (five) and European (one) countries. In detecting iodine in salt at 0 mg/kg, the RTK had an AR>90 % in eight of twenty-three surveys, while eight surveys had an AR90 %. The RTK is not suited for assessment of adequately iodized salt coverage. Quantitative assessment, such as by titration or WYD Checker, is necessary for estimates of adequately iodized salt coverage.

  15. 24 CFR 1006.330 - Insurance coverage.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Insurance coverage. 1006.330... DEVELOPMENT NATIVE HAWAIIAN HOUSING BLOCK GRANT PROGRAM Program Requirements § 1006.330 Insurance coverage. (a) In general. As a condition to receiving NHHBG funds, the DHHL must require adequate insurance...

  16. 7 CFR 1735.11 - Area coverage.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 11 2013-01-01 2013-01-01 false Area coverage. 1735.11 Section 1735.11 Agriculture Regulations of the Department of Agriculture (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE... Policies § 1735.11 Area coverage. Borrowers must make adequate telephone service available to the widest...

  17. Intrafractional dose variation and beam configuration in carbon ion radiotherapy for esophageal cancer.

    PubMed

    Haefner, M F; Sterzing, F; Krug, D; Koerber, S A; Jaekel, O; Debus, J; Haertig, M M

    2016-11-15

    In carbon ion radiotherapy (CIR) for esophageal cancer, organ and target motion is a major challenge for treatment planning due to potential range deviations. This study intends to analyze the impact of intrafractional variations on dosimetric parameters and to identify favourable settings for robust treatment plans. We contoured esophageal boost volumes in different organ localizations for four patients and calculated CIR-plans with 13 different beam geometries on a free-breathing CT. Forward calculation of these plans was performed on 4D-CT datasets representing seven different phases of the breathing cycle. Plan quality was assessed for each patient and beam configuration. Target volume coverage was adequate for all settings in the baseline CIR-plans (V 95  > 98% for two-beam geometries, > 94% for one-beam geometries), but reduced on 4D-CT plans (V 95 range 50-95%). Sparing of the organs at risk (OAR) was adequate, but range deviations during the breathing cycle partly caused critical, maximum doses to spinal cord up to 3.5x higher than expected. There was at least one beam configuration for each patient with appropriate plan quality. Despite intrafractional motion, CIR for esophageal cancer is possible with robust treatment plans when an individually optimized beam setup is selected depending on tumor size and localization.

  18. Phasing out of the Universal Mega Dose of Vitamin-A Prophylaxis to Avoid Toxicity.

    PubMed

    Bhattacharya, Sudip; Singh, Amarjeet

    2017-01-01

    Childhood blindness due to corneal ulceration was prevalent among poor Indian children. To tackle this situation, the National Institute of Nutrition (NIN), Hyderabad, India, Vitamin-A (Vit-A) prophylaxis programme was launched nationally in 1970 after field testing. Research of Indian Council for Medical Research (ICMR) documented that prevalence of Vit-A deficiency signs such as Bitot's spot decreased among children, over a period of time. However, this decrease cannot be ascertained is due to mass Vit-A prophylaxis programme. This is because coverage was low and patchy. Improved nutrition status, wider vaccination coverage, increased rate in breast feeding and improvement of healthcare services played a crucial role. Rather many studies revealed that (mass prophylaxis to the child who is having adequate Vit-A level) it may be harmful to certain group of children as a result of acute toxic symptoms. High dose of Vit-A is capable of loss of bone density-hence retarded growth may be observed in susceptible individuals. To tackle this issue food based approach should be promoted (which includes breast feeding) along with timely measles vaccination. The children who have signs of Vit-A deficiency (e.g. night blindness, xeropthalmia, Bitot's spot) or post measles children should receive Vit-A in age specific daily doses for two weeks along with Vit-A rich food, like green leafy vegetables, red palm oil, liver etc. Public spirited citizens, together with scientific community in India, should discourage this "one size fit to all" approach. It will not only avoid the ill effects of high dose of Vit-A but also it will help us optimal utilization of health resources in a resource poor country like India.

  19. Human Papillomavirus Vaccine Coverage and Prevalence of Missed Opportunities for Vaccination in an Integrated Healthcare System.

    PubMed

    Irving, Stephanie A; Groom, Holly C; Stokley, Shannon; McNeil, Michael M; Gee, Julianne; Smith, Ning; Naleway, Allison L

    2018-03-01

    Human papillomavirus (HPV) vaccination has been recommended in the United States for female and male adolescents since 2006 and 2011, respectively. Coverage rates are lower than those for other adolescent vaccines. The objective of this study was to evaluate an assessment and feedback intervention designed to increase HPV vaccination coverage and quantify missed opportunities for HPV vaccine initiation at preventive care visits. We examined changes in HPV vaccination coverage and missed opportunities within the adolescent (11-17 years) population at 9 Oregon-based Kaiser Permanente Northwest outpatient clinics after an assessment and feedback intervention. Quarterly coverage rates were calculated for the adolescent populations at the clinics, according to age group (11-12 and 13-17 years), sex, and department (Pediatrics and Family Medicine). Comparison coverage assessments were calculated at 3 nonintervention (control) clinics. Missed opportunities for HPV vaccine initiation, defined as preventive care visits in which a patient eligible for HPV dose 1 remained unvaccinated, were examined according to sex and age group. An average of 29,021 adolescents were included in coverage assessments. Before the intervention, 1-dose and 3-dose quarterly coverage rates were increasing at intervention as well as at control clinics in both age groups. Postimplementation quarterly trends in 1-dose or 3-dose coverage did not differ significantly between intervention and control clinics for either age group. One-dose coverage rates among adolescents with Pediatrics providers were significantly higher than those with Family Medicine providers (56% vs 41% for 11- to 12-year-old and 82% vs 69% for 13- to 17-year-old girls; 55% vs 40% for 11- to 12-year-old and 78% vs 62% for 13- to 17-year-old boys). No significant differences in HPV vaccine coverage were identified at intervention clinics. However, coverage rates were increasing before the start of the intervention and might have been influenced by ongoing health system best practices. HPV vaccine coverage rates varied significantly according to department, which could allow for targeted improvement opportunities. Copyright © 2017 Academic Pediatric Association. All rights reserved.

  20. Vaccination coverage among children in kindergarten - United States, 2012-13 school year.

    PubMed

    2013-08-02

    State and local school vaccination requirements are implemented to maintain high vaccination coverage and minimize the risk from vaccine preventable diseases. To assess school vaccination coverage and exemptions, CDC annually analyzes school vaccination coverage data from federally funded immunization programs. These awardees include 50 states and the District of Columbia (DC), five cities, and eight U.S.-affiliated jurisdictions. This report summarizes vaccination coverage from 48 states and DC and exemption rates from 49 states and DC for children entering kindergarten for the 2012-13 school year. Forty-eight states and DC reported vaccination coverage, with medians of 94.5% for 2 doses of measles, mumps, and rubella (MMR) vaccine; 95.1% for local requirements for diphtheria, tetanus toxoid, and acellular pertussis (DTaP) vaccination; and 93.8% for 2 doses of varicella vaccine among awardees with a 2-dose requirement. Forty-nine states and DC reported exemption rates, with the median total of 1.8%. Although school entry coverage for most awardees was at or near national Healthy People 2020 targets of maintaining 95% vaccination coverage levels for 2 doses of MMR vaccine, 4 doses of DTaP† vaccine, and 2 doses of varicella vaccine, low vaccination and high exemption levels can cluster within communities, increasing the risk for disease. Reports to CDC are aggregated at the state level; however, local reporting of school vaccination coverage might be accessible by awardees. These local-level data can be used to create evidence-based health communication strategies to help parents understand the risks for vaccine-preventable diseases and the benefits of vaccinations to the health of their children and other kindergarteners.

  1. Vaccination coverage among children in kindergarten - United States, 2013-14 school year.

    PubMed

    Seither, Ranee; Masalovich, Svetlana; Knighton, Cynthia L; Mellerson, Jenelle; Singleton, James A; Greby, Stacie M

    2014-10-17

    State and local vaccination requirements for school entry are implemented to maintain high vaccination coverage and protect schoolchildren from vaccine-preventable diseases. Each year, to assess state and national vaccination coverage and exemption levels among kindergartners, CDC analyzes school vaccination data collected by federally funded state, local, and territorial immunization programs. This report describes vaccination coverage in 49 states and the District of Columbia (DC) and vaccination exemption rates in 46 states and DC for children enrolled in kindergarten during the 2013-14 school year. Median vaccination coverage was 94.7% for 2 doses of measles, mumps, and rubella (MMR) vaccine; 95.0% for varying local requirements for diphtheria, tetanus toxoid, and acellular pertussis (DTaP) vaccine; and 93.3% for 2 doses of varicella vaccine among those states with a 2-dose requirement. The median total exemption rate was 1.8%. High exemption levels and suboptimal vaccination coverage leave children vulnerable to vaccine-preventable diseases. Although vaccination coverage among kindergartners for the majority of reporting states was at or near the 95% national Healthy People 2020 targets for 4 doses of DTaP, 2 doses of MMR, and 2 doses of varicella vaccine, low vaccination coverage and high exemption levels can cluster within communities. Immunization programs might have access to school vaccination coverage and exemption rates at a local level for counties, school districts, or schools that can identify areas where children are more vulnerable to vaccine-preventable diseases. Health promotion efforts in these local areas can be used to help parents understand the risks for vaccine-preventable diseases and the protection that vaccinations provide to their children.

  2. Dosimetric comparison of four different external beams for breast irradiation

    NASA Astrophysics Data System (ADS)

    Lee, Yoon Hee; Chung, Weon Kuu; Kim, Dong Wook; Kwon, Oh Young

    2017-02-01

    An intensity-modulated radiation-therapy (IMRT)-based technique, blocked single iso-centric IMRT (IMRT), is compared to multi-center IMRT (MIRT) and other conventional techniques such as three dimensional conformal radiation therapy (3D-CRT) and volumetric modulated arc therapy (VMAT) for the treatment of breast cancer patients. Four different plans were devised and compared for 15 breast cancer patients, all of whom had early stage disease and had undergone breast conserving surgery. A total dose of 50.4 Gy in 28 fractions was prescribed as the planning target volume in all treatment plans. The doses to the ipsilateral lung, heart, and opposite breast were compared using a dose-volume histogram. The conformity index (CI), homogeneity index (HI), and coverage index (CoVI) were evaluated and compared among the four treatment techniques. The lifetime attributable risk (LAR) associated with each of the four techniques from age at exposure of 30 to 100 years was measured for the organs at risk. We found that MIRT had a better CoVI (1.02 ± 0.13 and 1.01 ± 0.04, respectively) and IMRT had a better CI (0.88 ± 0.04, and 0.87 ± 0.02, respectively) compared to the other three modalities. All four techniques had similar HIs. Moreover, we found that IMRT and MIRT were less likely to cause radiation induced-pneumonitis, 3D-CRT had the lowest LAR, IMRT and MIRT had similar LARs and VMAT had the highest LAR. In study we found that compared to the VMAT, MIRT and IMRT provided adequate the planning target volume (PTV) coverage and reduced the risk of secondary cancers in most of the organs at risk (OARs), while 3D-CRT had the lowest secondary-cancer risks. Therefore, 3D-CRT is still a reasonable choice for whole breast RT except for patients with complex PTV shapes, in which cases IMRT and MIRT may provide better target coverage.

  3. Critical appraisal of volumetric-modulated arc therapy compared with electrons for the radiotherapy of cutaneous Kaposi's sarcoma of lower extremities with bone sparing.

    PubMed

    Nicolini, G; Abraham, S; Fogliata, A; Jordaan, A; Clivio, A; Vanetti, E; Cozzi, L

    2013-03-01

    To evaluate the use of volumetric-modulated arc therapy [VMAT, RapidArc® (RA); Varian Medical Systems, Palo Alto, CA] for the treatment of cutaneous Kaposi's sarcoma (KS) of lower extremities with adequate target coverage and high bone sparing, and to compare VMAT with electron beam therapy. 10 patients were planned with either RA or electron beams. The dose was prescribed to 30 Gy, 10 fractions, to mean the planning target volume (PTV), and significant maximum dose to bone was limited to 30 Gy. Plans were designed for 6-MV photon beams for RA and 6 MeV for electrons. Dose distributions were computed with AcurosXB® (Varian Medical Systems) for photons and with a Monte Carlo algorithm for electrons. V(90%) was 97.3±1.2 for RA plans and 78.2±2.6 for electrons; similarly, V(107%) was 2.5±2.2 and 37.7±3.4, respectively. RA met coverage criteria. Concerning bone sparing, D(2%) was 29.6±1.1 for RA and 31.0±2.4 for electrons. Although acceptable for bone involvement, pronounced target coverage violations were obtained for electron plans. Monitor units were similar for electrons and RA, although for the latter they increased when superior bone sparing was imposed. Delivery times were 12.1±4.0 min for electrons and 4.8±1.3 min for the most modulated RA plans. High plan quality was shown for KS in the lower extremities using VMAT, and this might simplify their management in comparison with the more conventional usage of electrons, particularly in institutes with limited staff resources and heavy workloads. VMAT is also dosimetrically extremely advantageous in a typology of treatments where electron beam therapy is mainly considered to be effective owing to the limited penetration of the beams.

  4. SU-E-T-292: Dosimetric Advantage of Prone Breast Radiotherapy for Korean Left-Sided Breast Cancer Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chung, Y; Shin, J; Yu, J

    Purpose: To evaluate the dosimetric benefit of prone breast radiotherapy for Korean left-sided early-stage breast cancer patients who have relatively small breast Methods: From April to June, 2014, 10 left-sided breast cancer patients received the whole breast irradiation in prone position after partial mastectomy with sentinel lymph node biopsy or axillary lymph node dissection. All patients were pTmi-2N0-1mi. Each patient underwent two computed tomoradiography (CT) simulations in supine and prone positions. The whole breast, ipsilateral lung, heart, and left anterior descending coronary artery (LAD) were contoured on each simulation CT images, and then tangential-fields treatment plan in each position wasmore » designed for the whole breast irradiation with the total dose of 50 Gy in 2 Gy fractions. Dose-volume histograms of two setups were compared for target coverage and radiation dose to normal organs with Wilcoxon signed rank tests. Results: The median age of patients was 47 years (range, 37 to 53). The median chest size was 82.5 cm (range, 75 to 90) and bra cup size was A in 4, B in 4, and C in 2 patients. The radiation dose to the whole breast was similar when comparing mean dose (Dmean) and dose covering 95% of the breast volume, but maximum dose (Dmax) of breast was higher in supine (median 52.3 vs. 52.7 Gy, p=0.013). Prone position reduced significantly the radiation dose in ipsilateral lung, heart, and LAD by median 5.7, 1.1, and 6.9 Gy of Dmean (p=0.005, 0.007, and 0.005) and 28.2, 18.8, and 35.0 Gy of Dmax (p=0.005, 0.005, and 0.007), respectively. Conclusion: Prone breast radiotherapy could be beneficial for Korean breast cancer patients since it substantially spared normal organs while achieving adequate coverage of the breast tissue. Further prospective study is required to validate the potential benefit of prone breast radiotherapy.« less

  5. Health Insurance and Children with Disabilities

    ERIC Educational Resources Information Center

    Szilagyi, Peter G.

    2012-01-01

    Few people would disagree that children with disabilities need adequate health insurance. But what kind of health insurance coverage would be optimal for these children? Peter Szilagyi surveys the current state of insurance coverage for children with special health care needs and examines critical aspects of coverage with an eye to helping policy…

  6. SU-F-T-36: Dosimetric Comparison of Point Based Vs. Target Based Prescription for Intracavitary Brachytherapy in Cancer of the Cervix

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ashenafi, M; McDonald, D; Peng, J

    Purpose: Improved patient imaging used for planning the treatment of cervical cancer with Tandem and Ovoid (T&O) Intracavitary high-dose-rate brachytherapy (HDR) now allows for 3D delineation of target volumes and organs-at-risk. However, historical data relies on the conventional point A-based planning technique. A comparative dosimetric study was performed by generating both target-based (TBP) and point-based (PBP) plans for ten clinical patients. Methods: Treatment plans created using Elekta Oncentra v. 4.3 for ten consecutive cervical cancer patients were analyzed. All patients were treated with HDR using the Utrecht T&O applicator. Both CT and MRI imaging modalities were utilized to delineate clinicalmore » target volume (CTV) and organs-at-risk (rectum, sigmoid, bladder, and small bowel). Point A (left and right), vaginal mucosa, and ICRU rectum and bladder points were defined on CT. Two plans were generated for each patient using two prescription methods (PBP and TBP). 7Gy was prescribed to each point A for each PBP plan and to the target D90% for each TBP plan. Target V90%, V100%, and V200% were evaluated. In addition, D0.1cc and D2cc were analyzed for each organ-at-risk. Differences were assessed for statistical significance (p<0.05) by use of Student’s t-test. Results: Target coverage was comparable for both planning methods, with each method providing adequate target coverage. TBP showed lower absolute dose to the target volume than PBP (D90% = 7.0Gy vs. 7.4Gy, p=0.028), (V200% = 10.9cc vs. 12.8cc, p=0.014), (ALeft = 6.4Gy vs. 7Gy, p=0.009), and (ARight = 6.4Gy vs. 7Gy, p=0.013). TBP also showed a statistically significant reduction in bladder, rectum, small bowel, and sigmoid doses compared to PBP. There was no statistically significant difference in vaginal mucosa or ICRU-defined rectum and bladder dose. Conclusion: Target based prescription resulted in substantially lower dose to delineated organs-at-risk compared to point based prescription, while maintaining similar target coverage.« less

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Yao; Chen, Josephine; Leary, Celeste I.

    Radiation of the low neck can be accomplished using split-field intensity-modulated radiation therapy (sf-IMRT) or extended-field intensity-modulated radiation therapy (ef-IMRT). We evaluated the effect of these treatment choices on target coverage and thyroid and larynx doses. Using data from 14 patients with cancers of the oropharynx, we compared the following 3 strategies for radiating the low neck: (1) extended-field IMRT, (2) traditional split-field IMRT with an initial cord-junction block to 40 Gy, followed by a full-cord block to 50 Gy, and (3) split-field IMRT with a full-cord block to 50 Gy. Patients were planned using each of these 3 techniques.more » To facilitate comparison, extended-field plans were normalized to deliver 50 Gy to 95% of the neck volume. Target coverage was assessed using the dose to 95% of the neck volume (D{sub 95}). Mean thyroid and larynx doses were computed. Extended-field IMRT was used as the reference arm; the mean larynx dose was 25.7 ± 7.4 Gy, and the mean thyroid dose was 28.6 ± 2.4 Gy. Split-field IMRT with 2-step blocking reduced laryngeal dose (mean larynx dose 15.2 ± 5.1 Gy) at the cost of a moderate reduction in target coverage (D{sub 95} 41.4 ± 14 Gy) and much higher thyroid dose (mean thyroid dose 44.7 ± 3.7 Gy). Split-field IMRT with initial full-cord block resulted in greater laryngeal sparing (mean larynx dose 14.2 ± 5.1 Gy) and only a moderately higher thyroid dose (mean thyroid dose 31 ± 8 Gy) but resulted in a significant reduction in target coverage (D{sub 95} 34.4 ± 15 Gy). Extended-field IMRT comprehensively covers the low neck and achieves acceptable thyroid and laryngeal sparing. Split-field IMRT with a full-cord block reduces laryngeal doses to less than 20 Gy and spares the thyroid, at the cost of substantially reduced coverage of the low neck. Traditional 2-step split-field IMRT similarly reduces the laryngeal dose but also reduces low-neck coverage and delivers very high doses to the thyroid.« less

  8. A cross-sectional vaccination coverage study in preschool children attending nurseries-kindergartens: Implications on economic crisis effect

    PubMed Central

    Menegas, Damianos; Katsioulis, Antonis; Theodoridou, Maria; Kremastinou, Jenny; Hadjichristodoulou, Christos

    2017-01-01

    ABSTRACT Vaccination coverage studies are important in determining a population's vaccination status and strategically adjusting national immunization programs. This study assessed full and timely vaccination coverage of preschool children aged 2–3 y attending nurseries-kindergartens (N-K) nationwide at the socioeconomic crisis onset. Geographically stratified cluster sampling was implemented considering prefectures as strata and N-K as clusters. The N-K were selected by simple random sampling from the sampling frame while their number was proportional to the stratum size. In total, 185 N-K (response rate 93.9%) and 2539 children (response rate 81.5%) participated. Coverage with traditional vaccines for diphtheria-tetanus-pertussis, polio and measles-mumps-rubella was very high (>95%), followed by Haemophilus influenzae type b and varicella vaccines. Despite very high final coverage, delayed vaccination was observed for hepatitis B (48.3% completed by 12 months). Significant delay was observed for the booster dose of pneumococcal conjugate vaccines (PCV) and meningococcal C conjugate vaccines (MCC). Of the total population studied, 82.3% received 3 PCV doses by 12 months, while 62.3% received the fourth dose by 24 months and 76.2% by 30 months. However, 89.6% received at least one MCC dose over 12 months. Timely vaccinated for hepatitis A with 2 doses by 24 months were 6.1%. Coverage was significantly low for Rotavirus (<20%) and influenza (23.1% one dose). High vaccination coverage is maintained for most vaccines at the beginning of the crisis in Greece. Coverage and timeliness show an increasing trend compared to previous studies. Sustained efforts are needed to support the preventive medicine system as socioeconomic instability continues. PMID:27669156

  9. A practical application of practice-based learning: development of an algorithm for empiric antibiotic coverage in ventilator-associated pneumonia.

    PubMed

    Miller, Preston R; Partrick, Matthew S; Hoth, J Jason; Meredith, J Wayne; Chang, Michael C

    2006-04-01

    Development of practice-based learning (PBL) is one of the core competencies required for resident education by the Accreditation Council for Graduate Medical Education, and specialty organizations including the American College of Surgeons have formed task forces to understand and disseminate information on this important concept. However, translating this concept into daily practice may be difficult. Our goal was to describe the successful application of PBL to patient care improvement with development of an algorithm for the empiric therapy of ventilator-associated pneumonia (VAP). The algorithm development occurred in two phases. In phase 1, the microbiology and timing of VAP as diagnosed by bronchoalveolar lavage was reviewed over a 2-year period to allow for recognition of patterns of infection. In phase 2, based on these data, an algorithm for empiric antibiotic coverage that would ensure that the large majority of patients with VAP received adequate initial empiric therapy was developed and put into practice. The period of algorithm use was then examined to determine rate of adequate coverage and outcome. : In Phase 1, from January 1, 2000 to December 31 2001, 110 patients were diagnosed with VAP. Analysis of microbiology revealed a sharp increase in the recovery of nosocomial pathogens on postinjury day 7 (19% < day 7 versus 47% > or = day 7, p = 0.003). Adequate initial antibiotic coverage was seen in 74%. In Phase 2, an algorithm employing ampicillin- sulbactam for coverage of community- acquired pathogens before day 7 and cefipime for nosocomial coverage > or =day 7 was then employed from January 1, 2002 to December 31, 2003. Evaluation of 186 VAP cases during this interval revealed a similar distribution of nosocomial cases (13% < day 7 versus 64% > or = day 7, p < 0.0001). Empiric antibiotic therapy was adequate in 82% of cases or =day 7: overall accuracy improved to 83% (p = 0.05). Mortality from phase 1 to phase 2 trended toward a decrease (21% versus 13%, p = 0.1). Application of the concept of PBL allowed for identification of local patterns of infection and development of an institution specific treatment algorithm that resulted in >80% adequate initial empiric coverage for VAP with a trend toward decreased mortality. PBL allows for alteration in practice based on local patterns and outcomes and has the potential to improve patient care.

  10. Estimation of Nationwide Vaccination Coverage and Comparison of Interview and Telephone Survey Methodology for Estimating Vaccination Status

    PubMed Central

    Park, Boyoung; Lee, Yeon-Kyeng; Cho, Lisa Y.; Go, Un Yeong; Yang, Jae Jeong; Ma, Seung Hyun; Choi, Bo-Youl; Lee, Moo-Sik; Lee, Jin-Seok; Choi, Eun Hwa; Lee, Hoan Jong

    2011-01-01

    This study compared interview and telephone surveys to select the better method for regularly estimating nationwide vaccination coverage rates in Korea. Interview surveys using multi-stage cluster sampling and telephone surveys using stratified random sampling were conducted. Nationwide coverage rates were estimated in subjects with vaccination cards in the interview survey. The interview survey relative to the telephone survey showed a higher response rate, lower missing rate, higher validity and a less difference in vaccination coverage rates between card owners and non-owners. Primary vaccination coverage rate was greater than 90% except for the fourth dose of DTaP (diphtheria/tetanus/pertussis), the third dose of polio, and the third dose of Japanese B encephalitis (JBE). The DTaP4: Polio3: MMR1 fully vaccination rate was 62.0% and BCG1:HepB3:DTaP4:Polio3:MMR1 was 59.5%. For age-appropriate vaccination, the coverage rate was 50%-80%. We concluded that the interview survey was better than the telephone survey. These results can be applied to countries with incomplete registry and decreasing rates of landline telephone coverage due to increased cell phone usage and countries. Among mandatory vaccines, efforts to increase vaccination rate for the fourth dose of DTaP, the third dose of polio, JBE and regular vaccinations at recommended periods should be conducted in Korea. PMID:21655054

  11. Impact of the introduction of rotavirus vaccine on the timeliness of other scheduled vaccines: the Australian experience.

    PubMed

    Hull, Brynley P; Menzies, Robert; Macartney, Kristine; McIntyre, Peter B

    2013-04-08

    Strict age limits for receipt of rotavirus vaccines and simultaneous use of vaccines requiring two (Rotarix(®)) and three (RotaTeq(®)) doses in Australia may impact on coverage and timeliness of other vaccines in the infant schedule. Using data from the Australian Childhood Immunisation Register (ACIR), coverage and timeliness of rotavirus vaccines and changes in timeliness of other infant vaccines following rotavirus vaccine introduction was examined, with particular emphasis on Indigenous infants in whom coverage is less optimal. Final dose rotavirus coverage reached 83% within 21 months of program commencement but remained 7% lower than other vaccines due in infancy. Coverage was 11-17% lower in Indigenous infants. Adherence to the first dose upper age limits for rotavirus vaccine was high with >97% of children vaccinated by the recommended age, but for subsequent rotavirus doses, receipt beyond the upper age limits was more common, especially in Indigenous children. Following rotavirus vaccine introduction, there were improvements in timeliness of receipt of all doses of DTPa-containing and 7-valent pneumococcal conjugate vaccines. High population coverage can be attained with rotavirus vaccines, even with adherence to strict upper age restrictions for vaccine dose administration. Rotavirus vaccine introduction appears to have impacted upon the timeliness of other concomitantly scheduled vaccines. These factors should be considered when rotavirus programs are introduced. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. A Clinical Concept for Interfractional Adaptive Radiation Therapy in the Treatment of Head and Neck Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jensen, Alexandra D., E-mail: Alexandra.Jensen@med.uni-heidelberg.de; Nill, Simeon; Huber, Peter E.

    Purpose: To present an approach to fast, interfractional adaptive RT in intensity-modulated radiation therapy (IMRT) of head and neck tumors in clinical routine. Ensuring adequate patient position throughout treatment proves challenging in high-precision RT despite elaborate immobilization. Because of weight loss, treatment plans must be adapted to account for requiring supportive therapy incl. feeding tube or parenteral nutrition without treatment breaks. Methods and Materials: In-room CT position checks are used to create adapted IMRT treatment plans by stereotactic correlation to the initial setup, and volumes are adapted to the new geometry. New IMRT treatment plans are prospectively created on themore » basis of position control scans using the initial optimization parameters in KonRad without requiring complete reoptimization and thus facilitating quick replanning in daily routine. Patients treated for squamous cell head and neck cancer (SCCHN) in 2006-2007 were evaluated as to necessity/number of replannings, weight loss, dose, and plan parameters. Results: Seventy-two patients with SCCHN received IMRT to the primary site and lymph nodes (median dose 70.4 Gy). All patients received concomitant chemotherapy requiring supportive therapy by feeding tube or parenteral nutrition. Median weight loss was 7.8 kg, median volume loss was approximately 7%. Fifteen of 72 patients required adaptation of their treatment plans at least once. Target coverage was improved by up to 10.7% (median dose). The increase of dose to spared parotid without replanning was 11.7%. Replanning including outlining and optimization was feasible within 2 hours for each patient, and treatment could be continued without any interruptions. Conclusion: To preserve high-quality dose application, treatment plans must be adapted to anatomical changes. Replanning based on position control scans therefore presents a practical approach in clinical routine. In the absence of clinically usable online correction methods, this approach allows significant improvement of target volume coverage and continuous parotid sparing without treatment delays.« less

  13. A clinical concept for interfractional adaptive radiation therapy in the treatment of head and neck cancer.

    PubMed

    Jensen, Alexandra D; Nill, Simeon; Huber, Peter E; Bendl, Rolf; Debus, Jürgen; Münter, Marc W

    2012-02-01

    To present an approach to fast, interfractional adaptive RT in intensity-modulated radiation therapy (IMRT) of head and neck tumors in clinical routine. Ensuring adequate patient position throughout treatment proves challenging in high-precision RT despite elaborate immobilization. Because of weight loss, treatment plans must be adapted to account for requiring supportive therapy incl. feeding tube or parenteral nutrition without treatment breaks. In-room CT position checks are used to create adapted IMRT treatment plans by stereotactic correlation to the initial setup, and volumes are adapted to the new geometry. New IMRT treatment plans are prospectively created on the basis of position control scans using the initial optimization parameters in KonRad without requiring complete reoptimization and thus facilitating quick replanning in daily routine. Patients treated for squamous cell head and neck cancer (SCCHN) in 2006-2007 were evaluated as to necessity/number of replannings, weight loss, dose, and plan parameters. Seventy-two patients with SCCHN received IMRT to the primary site and lymph nodes (median dose 70.4 Gy). All patients received concomitant chemotherapy requiring supportive therapy by feeding tube or parenteral nutrition. Median weight loss was 7.8 kg, median volume loss was approximately 7%. Fifteen of 72 patients required adaptation of their treatment plans at least once. Target coverage was improved by up to 10.7% (median dose). The increase of dose to spared parotid without replanning was 11.7%. Replanning including outlining and optimization was feasible within 2 hours for each patient, and treatment could be continued without any interruptions. To preserve high-quality dose application, treatment plans must be adapted to anatomical changes. Replanning based on position control scans therefore presents a practical approach in clinical routine. In the absence of clinically usable online correction methods, this approach allows significant improvement of target volume coverage and continuous parotid sparing without treatment delays. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. SU-F-BRA-04: Prostate HDR Brachytherapy with Multichannel Robotic System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joseph, F Maria; Podder, T; Yu, Y

    Purpose: High-dose-rate (HDR) brachytherapy is gradually becoming popular in treating patients with prostate cancers. However, placement of the HDR needles at desired locations into the patient is challenging. Application of robotic system may improve the accuracy of the clinical procedure. This experimental study is to evaluate the feasibility of using a multichannel robotic system for prostate HDR brachytherapy. Methods: In this experimental study, the robotic system employed was a 6-DOF Multichannel Image-guided Robotic Assistant for Brachytherapy (MIRAB), which was designed and fabricated for prostate seed implantation. The MIRAB has the provision of rotating 16 needles while inserting them. Ten prostatemore » HDR brachytherapy needles were simultaneously inserted using MIRAB into a commercially available prostate phantom. After inserting the needles into the prostate phantom at desired locations, 2mm thick CT slices were obtained for dosimetric planning. HDR plan was generated using Oncetra planning system with a total prescription dose of 34Gy in 4 fractions. Plan quality was evaluated considering dose coverage to prostate and planning target volume (PTV), with 3mm margin around prostate, as well as the dose limit to the organs at risk (OARs) following the American Brachytherapy Society (ABS) guidelines. Results: From the CT scan, it is observed that the needles were inserted straight into the desired locations and they were adequately spaced and distributed for a clinically acceptable HDR plan. Coverage to PTV and prostate were about 91% (V100= 91%) and 96% (V100=96%), respectively. Dose to 1cc of urethra, rectum, and bladder were within the ABS specified limits. Conclusion: The MIRAB was able to insert multiple needles simultaneously into the prostate precisely. By controlling the MIRAB to insert all the ten utilized needles into the prostate phantom, we could achieve the robotic HDR brachytherapy successfully. Further study for assessing the system’s performance and reliability is in progress.« less

  15. Lexical Threshold Revisited: Lexical Text Coverage, Learners' Vocabulary Size and Reading Comprehension

    ERIC Educational Resources Information Center

    Laufer, Batia; Ravenhorst-Kalovski, Geke C.

    2010-01-01

    We explore the relationship between second language (L2) learners' vocabulary size, lexical text coverage that their vocabulary provides and their reading comprehension. We also conceptualize "adequate reading comprehension" and look for the lexical threshold for such reading in terms of coverage and vocabulary size. Vocabulary size was…

  16. [Vaccination coverage against hepatitis B in first-grade children, Paris, 2002-2008].

    PubMed

    Personne, V; Benainous, O; Lévy-Bruhl, D; Gilberg, S

    2015-08-01

    The French controversy over the possible risks of vaccination against hepatitis B seems to have resulted in a slowdown or delay in vaccination of target populations since the mid-1990s. This article reports the results of the analysis of vaccination coverage against hepatitis B of first-grade children in Paris between 2002 and 2008. Retrospective and descriptive study of vaccination status against hepatitis B for children born between 1997 and 2002 and attending first grade in a Paris school between 2002 and 2008, using anonymous data from the prevention service of the city of Paris. The analysis included 108,114 children whose Health Book (carnet de santé) included sociodemographic data and the presence of at least one diphtheria-tetanus-polio vaccination. Among these targeted children, 66,597 (61.6%) had started a vaccination against hepatitis B, 61,190 (56.6%) were considered "vaccinated" (at least three doses), and 47,489 (43.9%) "adequately vaccinated" (at least three doses respecting the prescribed intervals between injections). The sociodemographic factors associated with hepatitis B coverage were as follows: Paris arrondissement where the child attended school, year, and country of birth. Nearly 40% of the children in this cohort had not been vaccinated against hepatitis B before beginning first grade. They have now become adolescents aged 12-17 years. Current data indicate that only one-third of them have benefited from the catch-up campaign. This finding reinforces the need for vigilance on the vaccination status of adolescents against hepatitis B. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  17. Human papillomavirus (HPV) vaccination coverage in young Australian women is higher than previously estimated: independent estimates from a nationally representative mobile phone survey.

    PubMed

    Brotherton, Julia M L; Liu, Bette; Donovan, Basil; Kaldor, John M; Saville, Marion

    2014-01-23

    Accurate estimates of coverage are essential for estimating the population effectiveness of human papillomavirus (HPV) vaccination. Australia has a purpose built National HPV Vaccination Program Register for monitoring coverage, however notification of doses administered to young women in the community during the national catch-up program (2007-2009) was not compulsory. In 2011, we undertook a population-based mobile phone survey of young women to independently estimate HPV vaccination coverage. Randomly generated mobile phone numbers were dialed to recruit women aged 22-30 (age eligible for HPV vaccination) to complete a computer assisted telephone interview. Consent was sought to validate self reported HPV vaccination status against the national register. Coverage rates were calculated based on self report and weighted to the age and state of residence structure of the Australian female population. These were compared with coverage estimates from the register using Australian Bureau of Statistics estimated resident populations as the denominator. Among the 1379 participants, the national estimate for self reported HPV vaccination coverage for doses 1/2/3, respectively, weighted for age and state of residence, was 64/59/53%. This compares with coverage of 55/45/32% and 49/40/28% based on register records, using 2007 and 2011 population data as the denominators respectively. Some significant differences in coverage between the states were identified. 20% (223) of women returned a consent form allowing validation of doses against the register and provider records: among these women 85.6% (538) of self reported doses were confirmed. We confirmed that coverage rates for young women vaccinated in the community (at age 18-26 years) are underestimated by the national register and that under-notification is greater for second and third doses. Using 2011 population estimates, rather than estimates contemporaneous with the program rollout, reduces register-based coverage estimates further because of large population increases due to immigration since the program. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. An Analysis of Plan Robustness for Esophageal Tumors: Comparing Volumetric Modulated Arc Therapy Plans and Spot Scanning Proton Planning.

    PubMed

    Warren, Samantha; Partridge, Mike; Bolsi, Alessandra; Lomax, Anthony J; Hurt, Chris; Crosby, Thomas; Hawkins, Maria A

    2016-05-01

    Planning studies to compare x-ray and proton techniques and to select the most suitable technique for each patient have been hampered by the nonequivalence of several aspects of treatment planning and delivery. A fair comparison should compare similarly advanced delivery techniques from current clinical practice and also assess the robustness of each technique. The present study therefore compared volumetric modulated arc therapy (VMAT) and single-field optimization (SFO) spot scanning proton therapy plans created using a simultaneous integrated boost (SIB) for dose escalation in midesophageal cancer and analyzed the effect of setup and range uncertainties on these plans. For 21 patients, SIB plans with a physical dose prescription of 2 Gy or 2.5 Gy/fraction in 25 fractions to planning target volume (PTV)50Gy or PTV62.5Gy (primary tumor with 0.5 cm margins) were created and evaluated for robustness to random setup errors and proton range errors. Dose-volume metrics were compared for the optimal and uncertainty plans, with P<.05 (Wilcoxon) considered significant. SFO reduced the mean lung dose by 51.4% (range 35.1%-76.1%) and the mean heart dose by 40.9% (range 15.0%-57.4%) compared with VMAT. Proton plan robustness to a 3.5% range error was acceptable. For all patients, the clinical target volume D98 was 95.0% to 100.4% of the prescribed dose and gross tumor volume (GTV) D98 was 98.8% to 101%. Setup error robustness was patient anatomy dependent, and the potential minimum dose per fraction was always lower with SFO than with VMAT. The clinical target volume D98 was lower by 0.6% to 7.8% of the prescribed dose, and the GTV D98 was lower by 0.3% to 2.2% of the prescribed GTV dose. The SFO plans achieved significant sparing of normal tissue compared with the VMAT plans for midesophageal cancer. The target dose coverage in the SIB proton plans was less robust to random setup errors and might be unacceptable for certain patients. Robust optimization to ensure adequate target coverage of SIB proton plans might be beneficial. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  19. An Evaluation of Voluntary Varicella Vaccination Coverage in Zhejiang Province, East China.

    PubMed

    Hu, Yu; Chen, Yaping; Zhang, Bing; Li, Qian

    2016-06-03

    In 2014 a 2-doses varicella vaccine (VarV) schedule was recommended by the Zhejiang Provincial Center for Disease Control and Prevention. We aimed to assess the coverage of the 1st dose of VarV (VarV₁) and the 2nd dose of VarV (VarV₂) among children aged 2-6 years through the Zhejiang Provincial Immunization Information System (ZJIIS) and to explore the determinants associated with the VarV coverage. Children aged 2-6 years (born from 1 January 2009 to 31 December 2013) registered in ZJIIS were enrolled. Anonymized individual records of target children were extracted from the ZJIIS database on 1 January 2016, including their VarV and (measles-containing vaccine) MCV vaccination information. The VarV₁ and VarV₂ coverage rates were evaluated for each birth cohorts. The coverage of VarV also was estimated among strata defined by cities, gender and immigration status. We also evaluated the difference in coverage between VarV and MCV. A total of 3,028,222 children aged 2-6 years were enrolled. The coverage of VarV₁ ranged from 84.8% to 87.9% in the 2009-2013 birth cohorts, while the coverage of VarV₂ increased from 31.8% for the 2009 birth cohort to 48.7% for the 2011 birth cohort. Higher coverage rates for both VarV₁ and VarV₂ were observed among resident children in relevant birth cohorts. The coverage rates of VarV₁ and VarV₂ were lower than those for the 1st and 2nd dose of MCV, which were above 95%. The proportion of children who were vaccinated with VarV₁ at the recommended age increased from 34.6% for the 2009 birth cohort to 75.2% for the 2013 birth cohort, while the proportion of children who were vaccinated with VarV₂ at the recommended age increased from 19.7% for the 2009 birth cohort to 48.7% for the 2011 birth cohort. Our study showed a rapid increasing VarV₂ coverage of children, indicating a growing acceptance of the 2-doses VarV schedule among children's caregivers and physicians after the new recommendation released. We highlighted the necessity for a 2-doses VarV vaccination school-entry requirement to achieve the high coverage of >90% and to eliminate disparities in coverage among sub-populations. We also recommended continuous monitoring of the VarV coverage via ZJIIS over time.

  20. Assessing vaccination coverage in infants, survey studies versus the Flemish immunisation register: achieving the best of both worlds.

    PubMed

    Braeckman, Tessa; Lernout, Tinne; Top, Geert; Paeps, Annick; Roelants, Mathieu; Hoppenbrouwers, Karel; Van Damme, Pierre; Theeten, Heidi

    2014-01-09

    Infant immunisation coverage in Flanders, Belgium, is monitored through repeated coverage surveys. With the increased use of Vaccinnet, the web-based ordering system for vaccines in Flanders set up in 2004 and linked to an immunisation register, this database could become an alternative to quickly estimate vaccination coverage. To evaluate its current accuracy, coverage estimates generated from Vaccinnet alone were compared with estimates from the most recent survey (2012) that combined interview data with data from Vaccinnet and medical files. Coverage rates from registrations in Vaccinnet were systematically lower than the corresponding estimates obtained through the survey (mean difference 7.7%). This difference increased by dose number for vaccines that require multiple doses. Differences in administration date between the two sources were observed for 3.8-8.2% of registered doses. Underparticipation in Vaccinnet thus significantly impacts on the register-based immunisation coverage estimates, amplified by underregistration of administered doses among vaccinators using Vaccinnet. Therefore, survey studies, despite being labour-intensive and expensive, currently provide more complete and reliable results than register-based estimates alone in Flanders. However, further improvement of Vaccinnet's completeness will likely allow more accurate estimates in the nearby future. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Iodine Status of Women of Reproductive Age in Sierra Leone and Its Association with Household Coverage with Adequately Iodized Salt

    PubMed Central

    Rohner, Fabian; Wirth, James P.; Woodruff, Bradley A.; Chiwile, Faraja; Yankson, Hannah; Sesay, Fatmata; Koroma, Aminata S.; Petry, Nicolai; Pyne-Bailey, Solade; Dominguez, Elisa; Kupka, Roland; Hodges, Mary H.; de Onis, Mercedes

    2016-01-01

    Salt iodization programs are a public health success in tackling iodine deficiency. Yet, a large proportion of the world’s population remains at risk for iodine deficiency. In a nationally representative cross-sectional survey in Sierra Leone, household salt samples and women’s urine samples were quantitatively analyzed for iodine content. Salt was collected from 1123 households, and urine samples from 817 non-pregnant and 154 pregnant women. Household coverage with adequately iodized salt (≥15 mg/kg iodine) was 80.7%. The median urinary iodine concentration (UIC) of pregnant women was 175.8 µg/L and of non-pregnant women 190.8 µg/L. Women living in households with adequately iodized salt had higher median UIC (for pregnant women: 180.6 µg/L vs. 100.8 µg/L, respectively, p < 0.05; and for non-pregnant women: 211.3 µg/L vs. 97.8 µg/L, p < 0.001). Differences in UIC by residence, region, household wealth, and women’s education were much smaller in women living in households with adequately iodized salt than in households without. Despite the high household coverage of iodized salt in Sierra Leone, it is important to reach the 20% of households not consuming adequately iodized salt. Salt iodization has the potential for increasing equity in iodine status even with the persistence of other risk factors for deficiency. PMID:26848685

  2. An Analysis of Plan Robustness for Esophageal Tumors: Comparing Volumetric Modulated Arc Therapy Plans and Spot Scanning Proton Planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warren, Samantha, E-mail: samantha.warren@oncology.ox.ac.uk; Partridge, Mike; Bolsi, Alessandra

    Purpose: Planning studies to compare x-ray and proton techniques and to select the most suitable technique for each patient have been hampered by the nonequivalence of several aspects of treatment planning and delivery. A fair comparison should compare similarly advanced delivery techniques from current clinical practice and also assess the robustness of each technique. The present study therefore compared volumetric modulated arc therapy (VMAT) and single-field optimization (SFO) spot scanning proton therapy plans created using a simultaneous integrated boost (SIB) for dose escalation in midesophageal cancer and analyzed the effect of setup and range uncertainties on these plans. Methods andmore » Materials: For 21 patients, SIB plans with a physical dose prescription of 2 Gy or 2.5 Gy/fraction in 25 fractions to planning target volume (PTV){sub 50Gy} or PTV{sub 62.5Gy} (primary tumor with 0.5 cm margins) were created and evaluated for robustness to random setup errors and proton range errors. Dose–volume metrics were compared for the optimal and uncertainty plans, with P<.05 (Wilcoxon) considered significant. Results: SFO reduced the mean lung dose by 51.4% (range 35.1%-76.1%) and the mean heart dose by 40.9% (range 15.0%-57.4%) compared with VMAT. Proton plan robustness to a 3.5% range error was acceptable. For all patients, the clinical target volume D{sub 98} was 95.0% to 100.4% of the prescribed dose and gross tumor volume (GTV) D{sub 98} was 98.8% to 101%. Setup error robustness was patient anatomy dependent, and the potential minimum dose per fraction was always lower with SFO than with VMAT. The clinical target volume D{sub 98} was lower by 0.6% to 7.8% of the prescribed dose, and the GTV D{sub 98} was lower by 0.3% to 2.2% of the prescribed GTV dose. Conclusions: The SFO plans achieved significant sparing of normal tissue compared with the VMAT plans for midesophageal cancer. The target dose coverage in the SIB proton plans was less robust to random setup errors and might be unacceptable for certain patients. Robust optimization to ensure adequate target coverage of SIB proton plans might be beneficial.« less

  3. Salivary gland sparing and improved target irradiation by conformal and intensity modulated irradiation of head and neck cancer.

    PubMed

    Eisbruch, Avraham; Ship, Jonathan A; Dawson, Laura A; Kim, Hyungjin M; Bradford, Carol R; Terrell, Jeffrey E; Chepeha, Douglas B; Teknos, Theodore N; Hogikyan, Norman D; Anzai, Yoshimi; Marsh, Lon H; Ten Haken, Randall K; Wolf, Gregory T

    2003-07-01

    The goals of this study were to facilitate sparing of the major salivary glands while adequately treating tumor targets in patients requiring comprehensive bilateral neck irradiation (RT), and to assess the potential for improved xerostomia. Since 1994 techniques of target irradiation and locoregional tumor control with conformal and intensity modulated radiation therapy (IMRT) have been developed. In patients treated with these modalities, the salivary flow rates before and periodically after RT have been measured selectively from each major salivary gland and the residual flows correlated with glands' dose volume histograms (DVHs). In addition, subjective xerostomia questionnaires have been developed and validated. The pattern of locoregional recurrence has been examined from computed tomography (CT) scans at the time of recurrence, transferring the recurrence volumes to the planning CT scans, and regenerating the dose distributions at the recurrence sites. Treatment plans for target coverage and dose homogeneity using static, multisegmental IMRT were found to be significantly better than standard RT plans. In addition, significant parotid gland sparing was achieved in the conformal plans. The relationships among dose, irradiated volume, and the residual saliva flow rates from the parotid glands were characterized by dose and volume thresholds. A mean radiation dose of 26 Gy was found to be the threshold for preserved stimulated saliva flow. Xerostomia questionnaire scores suggested that xerostomia was significantly reduced in patients irradiated with bilateral neck, parotid-sparing RT, compared to patients with similar tumors treated with standard RT. Examination of locoregional tumor recurrence patterns revealed that the large majority of recurrences occurred inside targets, in areas that had been judged to be at high risk and that had received RT doses according to the perceived risk. Tangible gains in salivary gland sparing and target coverage are being achieved, and an improvement in some measures of quality of life is suggested by our findings. Additional reduction of xerostomia may be achieved by further sparing of the salivary glands and the non-involved oral cavity. A mean parotid gland dose of < or = 26 Gy should be a planning objective if significant parotid function preservation is desired. The pattern of recurrence suggests that careful escalation of the dose to areas judged to be at highest risk may improve tumor control.

  4. An Analysis of Plan Robustness for Esophageal Tumors: Comparing Volumetric Modulated Arc Therapy Plans and Spot Scanning Proton Planning

    PubMed Central

    Warren, Samantha; Partridge, Mike; Bolsi, Alessandra; Lomax, Anthony J.; Hurt, Chris; Crosby, Thomas; Hawkins, Maria A.

    2016-01-01

    Purpose Planning studies to compare x-ray and proton techniques and to select the most suitable technique for each patient have been hampered by the nonequivalence of several aspects of treatment planning and delivery. A fair comparison should compare similarly advanced delivery techniques from current clinical practice and also assess the robustness of each technique. The present study therefore compared volumetric modulated arc therapy (VMAT) and single-field optimization (SFO) spot scanning proton therapy plans created using a simultaneous integrated boost (SIB) for dose escalation in midesophageal cancer and analyzed the effect of setup and range uncertainties on these plans. Methods and Materials For 21 patients, SIB plans with a physical dose prescription of 2 Gy or 2.5 Gy/fraction in 25 fractions to planning target volume (PTV)50Gy or PTV62.5Gy (primary tumor with 0.5 cm margins) were created and evaluated for robustness to random setup errors and proton range errors. Dose–volume metrics were compared for the optimal and uncertainty plans, with P<.05 (Wilcoxon) considered significant. Results SFO reduced the mean lung dose by 51.4% (range 35.1%-76.1%) and the mean heart dose by 40.9% (range 15.0%-57.4%) compared with VMAT. Proton plan robustness to a 3.5% range error was acceptable. For all patients, the clinical target volume D98 was 95.0% to 100.4% of the prescribed dose and gross tumor volume (GTV) D98 was 98.8% to 101%. Setup error robustness was patient anatomy dependent, and the potential minimum dose per fraction was always lower with SFO than with VMAT. The clinical target volume D98 was lower by 0.6% to 7.8% of the prescribed dose, and the GTV D98 was lower by 0.3% to 2.2% of the prescribed GTV dose. Conclusions The SFO plans achieved significant sparing of normal tissue compared with the VMAT plans for midesophageal cancer. The target dose coverage in the SIB proton plans was less robust to random setup errors and might be unacceptable for certain patients. Robust optimization to ensure adequate target coverage of SIB proton plans might be beneficial. PMID:27084641

  5. Immunization coverage among Hispanic ancestry, 2003 National Immunization Survey.

    PubMed

    Darling, Natalie J; Barker, Lawrence E; Shefer, Abigail M; Chu, Susan Y

    2005-12-01

    The Hispanic population is increasing and heterogeneous (Hispanic refers to persons of Spanish, Hispanic, or Latino descent). The objective was to examine immunization rates among Hispanic ancestry for the 4:3:1:3:3 series (> or = 4 doses diphtheria, tetanus toxoids, and pertussis vaccine; > or = 3 doses poliovirus vaccine; > or = 1 doses measles-containing vaccine; > or = 3 doses Haemophilus influenzae type b vaccine; and > or = 3 doses hepatitis B vaccine). The National Immunization Survey measures immunization coverage among 19- to 35-month-old U.S. children. Coverage was compared from combined 2001-2003 data among Hispanics and non-Hispanic whites using t-tests, and among Hispanic ancestry using a chi-square test. Hispanics were categorized as Mexican, Mexican American, Central American, South American, Puerto Rican, Cuban, Spanish Caribbean (primarily Dominican Republic), other, and multiple ancestry. Children of Hispanic ancestry increased from 21% in 1999 to 25% in 2003. These Hispanic children were less well immunized than non-Hispanic whites (77.0%, +/-2.1% [95% confidence interval] compared to 82.5%, +/-1.1% (95% CI) > in 2003). Immunization coverage did not vary significantly among Hispanics of varying ancestries (p=0.26); however, there was substantial geographic variability. In some areas, immunization coverage among Hispanics was significantly higher than non-Hispanic whites. Hispanic children were less well immunized than non-Hispanic whites; however, coverage varied notably by geographic area. Although a chi-square test found no significant differences in coverage among Hispanic ancestries, the range of coverage, 79.2%, +/-5.1% for Cuban Americans to 72.1%, +/-2.4% for Mexican descent, may suggest a need for improved and more localized monitoring among Hispanic communities.

  6. MO-F-CAMPUS-J-05: Using 2D Relative Gamma Analysis From EPID Image as a Predictor of Plan Deterioration Due to Anatomical Changes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piron, O; Varfalvy, N; Archambault, L

    2015-06-15

    Purpose: One of the side effects of radiotherapy for head and neck (H&N) cancer is the patient’s anatomical changes. The changes can strongly affect the planned dose distribution. In this work, our goal is to demonstrate that relative analysis of EPID images is a fast and simple method to detect anatomical changes that can have a strong dosimetric impact on the treatment plan for H&N patients. Methods: EPID images were recorded at every beam and all fractions for 50 H&N patients. Of these, five patients that showed important anatomical changes were selected to evaluate dosimetric impacts of these changes andmore » to correlate them with a 2D relative gamma analysis of EPID images. The planning CT and original contours were deformed onto CBCTs (one mid treatment and one at the end of treatment). By using deformable image registration, it was possible to map accurate CT numbers from the planning CT to the anatomy of the day obtained with CBCTs. Clinical treatment plan were then copied on the deformed dataset and dose was re-computed. In parallel, EPID images were analysed using the gamma index (3%3mm) relative to the first image. Results: It was possible to divide patients in two distinct, statistically different (p<0.001) categories using an average gamma index of 0.5 as a threshold. Below this threshold no significant dosimetric degradation of the plan are observed. Above this threshold two types of plan deterioration were seen: (1) target dose increases, but coverage remains adequate while dose to at least one OAR increases beyond tolerances; (2) the OAR doses remain low, but the target dose is reduced and coverage becomes inadequate. Conclusion: Relative analysis gamma of EPID images could indeed be a fast and simple method to detect anatomical changes that can potentially deteriorates treatment plan for H&N patients. This work was supported in part by Varian Medical System.« less

  7. Inequalities in full immunization coverage: trends in low- and middle-income countries

    PubMed Central

    Barros, Aluísio JD; Wong, Kerry LM; Johnson, Hope L; Pariyo, George; França, Giovanny VA; Wehrmeister, Fernando C; Victora, Cesar G

    2016-01-01

    Abstract Objective To investigate disparities in full immunization coverage across and within 86 low- and middle-income countries. Methods In May 2015, using data from the most recent Demographic and Health Surveys and Multiple Indicator Cluster Surveys, we investigated inequalities in full immunization coverage – i.e. one dose of bacille Calmette-Guérin vaccine, one dose of measles vaccine, three doses of vaccine against diphtheria, pertussis and tetanus and three doses of polio vaccine – in 86 low- or middle-income countries. We then investigated temporal trends in the level and inequality of such coverage in eight of the countries. Findings In each of the World Health Organization’s regions, it appeared that about 56–69% of eligible children in the low- and middle-income countries had received full immunization. However, within each region, the mean recorded level of such coverage varied greatly. In the African Region, for example, it varied from 11.4% in Chad to 90.3% in Rwanda. We detected pro-rich inequality in such coverage in 45 of the 83 countries for which the relevant data were available and pro-urban inequality in 35 of the 86 study countries. Among the countries in which we investigated coverage trends, Madagascar and Mozambique appeared to have made the greatest progress in improving levels of full immunization coverage over the last two decades, particularly among the poorest quintiles of their populations. Conclusion Most low- and middle-income countries are affected by pro-rich and pro-urban inequalities in full immunization coverage that are not apparent when only national mean values of such coverage are reported. PMID:27821882

  8. Coverage, efficacy or dosing interval: which factor predominantly influences the impact of routine childhood vaccination for the prevention of varicella? A model-based study for Italy.

    PubMed

    Holl, Katsiaryna; Sauboin, Christophe; Amodio, Emanuele; Bonanni, Paolo; Gabutti, Giovanni

    2016-10-21

    Varicella is a highly infectious disease with a significant public health and economic burden, which can be prevented with childhood routine varicella vaccination. Vaccination strategies differ by country. Some factors are known to play an important role (number of doses, coverage, dosing interval, efficacy and catch-up programmes), however, their relative impact on the reduction of varicella in the population remains unclear. This paper aims to help policy makers prioritise the critical factors to achieve the most successful vaccination programme with the available budget. Scenarios assessed the impact of different vaccination strategies on reduction of varicella disease in the population. A dynamic transmission model was used and adapted to fit Italian demographics and population mixing patterns. Inputs included coverage, number of doses, dosing intervals, first-dose efficacy and availability of catch-up programmes, based on strategies currently used or likely to be used in different countries. The time horizon was 30 years. Both one- and two-dose routine varicella vaccination strategies prevented a comparable number of varicella cases with complications, but two-doses provided broader protection due to prevention of a higher number of milder varicella cases. A catch-up programme in susceptible adolescents aged 10-14 years old reduced varicella cases by 27-43 % in older children, which are often more severe than in younger children. Coverage, for all strategies, sustained at high levels achieved the largest reduction in varicella. In general, a 20 % increase in coverage resulted in a further 27-31 % reduction in varicella cases. When high coverage is reached, the impact of dosing interval and first-dose vaccine efficacy had a relatively lower impact on disease prevention in the population. Compared to the long (11 years) dosing interval, the short (5 months) and medium (5 years) interval schedules reduced varicella cases by a further 5-13 % and 2-5 %, respectively. Similarly, a 10 % increase in first-dose efficacy (from 65 to 75 % efficacy) prevented 2-5 % more varicella cases, suggesting it is the least influential factor when considering routine varicella vaccination. Vaccination strategies can be implemented differently in each country depending on their needs, infrastructure and healthcare budget. However, ensuring high coverage remains the critical success factor for significant prevention of varicella when introducing varicella vaccination in the national immunisation programme.

  9. Evaluation of dose coverage to target volume and normal tissue sparing in the adjuvant radiotherapy of gastric cancers: 3D-CRT compared with dynamic IMRT.

    PubMed

    Murthy, Kk; Shukeili, Ka; Kumar, Ss; Davis, Ca; Chandran, Rr; Namrata, S

    2010-01-01

    To assess the potential advantage of intensity-modulated radiotherapy (IMRT) over 3D-conformal radiotherapy (3D-CRT) planning in postoperative adjuvant radiotherapy for patients with gastric carcinoma. In a retrospective study, for plan comparison, dose distribution was recalculated in 15 patients treated with 3D-CRT on the contoured structures of same CT images using an IMRT technique. 3D-conformal plans with three fields and four-fields were compared with seven-field dynamic IMRT plans. The different plans were compared by analyzing the dose coverage of planning target volume using TV(95), D(mean), uniformity index, conformity index and homogeneity index parameters. To assess critical organ sparing, D(mean), D(max), dose to one-third and two-third volumes of the OARs and percentage of volumes receiving more than their tolerance doses were compared. The average dose coverage values of PTV with 3F-CRT and 4F-CRT plans were comparable, where as IMRT plans achieved better target coverage(p<0.001) with higher conformity index value of 0.81±0.07 compared to both the 3D-CRT plans. The doses to the liver and bowel reduced significantly (p<0.001) with IMRT plans compared to other 3D-CRT plans. For all OARs the percentage of volumes receiving more than their tolerance doses were reduced with the IMRT plans. This study showed that a better target coverage and significant dose reduction to OARs could be achieved with the IMRT plans. The IMRT can be preferred with caution for organ motion. The authors are currently studying organ motion in the upper abdomen to use IMRT for patient treatment.

  10. Reduction of the unnecessary dose from the over-range area with a spiral dynamic z-collimator: comparison of beam pitch and detector coverage with 128-detector row CT.

    PubMed

    Shirasaka, Takashi; Funama, Yoshinori; Hayashi, Mutsukazu; Awamoto, Shinichi; Kondo, Masatoshi; Nakamura, Yasuhiko; Hatakenaka, Masamitsu; Honda, Hiroshi

    2012-01-01

    Our purpose in this study was to assess the radiation dose reduction and the actual exposed scan length of over-range areas using a spiral dynamic z-collimator at different beam pitches and detector coverage. Using glass rod dosimeters, we measured the unilateral over-range scan dose between the beginning of the planned scan range and the beginning of the actual exposed scan range. Scanning was performed at detector coverage of 80.0 and 40.0 mm, with and without the spiral dynamic z-collimator. The dose-saving ratio was calculated as the ratio of the unnecessary over-range dose, with and without the spiral dynamic z-collimator. In 80.0 mm detector coverage without the spiral dynamic z-collimator, the actual exposed scan length for the over-range area was 108, 120, and 126 mm, corresponding to a beam pitch of 0.60, 0.80, and 0.99, respectively. With the spiral dynamic z-collimator, the actual exposed scan length for the over-range area was 48, 66, and 84 mm with a beam pitch of 0.60, 0.80, and 0.99, respectively. The dose-saving ratios with and without the spiral dynamic z-collimator for a beam pitch of 0.60, 0.80, and 0.99 were 35.07, 24.76, and 13.51%, respectively. With 40.0 mm detector coverage, the dose-saving ratios with and without the spiral dynamic z-collimator had the highest value of 27.23% with a low beam pitch of 0.60. The spiral dynamic z-collimator is important for a reduction in the unnecessary over-range dose and makes it possible to reduce the unnecessary dose by means of a lower beam pitch.

  11. Vaccination coverage survey in Dhaka District.

    PubMed

    Khan, M N A; Rahman, M L; Awal Miah, A; Islam, M S; Musa, S A J M; Tofail, F

    2005-08-01

    A survey was conducted in Dhaka District to measure the level of routine immunization coverage of children (12-23 months), to assess the tetanus toxoid (TT) immunization coverage among mothers of children (12-23 month), to evaluate EPI program continuity (dropout rates) and quality (percent of Invalid doses, vaccination card availability etc.) For this purpose, a thirty cluster cross-sectional survey was conducted in October 2002 to assess the immunization coverage in Dhaka. In this survey 30 clusters were randomly selected from a list of villages in 63 Unions of Dhaka following probability proportion to size (PPS) sampling procedure. A total of 210 children was studied using pre-tested structured questionnaire. Descriptive statistics was employed using software SPSS package for data analysis. The study showed that the routine immunization coverage in Dhaka among children by 12 months of age by card + history was 97% for BCG, 97% for Diphtheria, Pertussis Tetanus (DPT 1) and Oral Polio Vaccine (OPV 1), 75% for DPT3 and OPV3 and 67% for measles. Sixty six percent of all children surveyed had received valid doses of all vaccines by 12 months (fully immunized child). Programme access as measured by crude DPT1 coverage was better in Keranigonj (97%). Vaccination cards retention rate for children was 84%. Invalid DPT (1,2 or 3) doses were given to 25% of vaccinated children; 18% of measles doses were invalid. Surprisingly, major cause for invalid doses were not due to early immunizations or due to card lost but for giving tick in the card, instead of writing a valid date. DPT1 and DPT3 and DPT1- Measles drop out rates were 5% and 13% respectively. Major reason parents gave for never vaccinating their children (zero dose children) was (43%), major reasons for incomplete vaccination was lack of knowledge regarding subsequent doses (46%). TT surveys were also conducted for mothers of the children surveyed for vaccination coverage (mothers between 15-49 year old). Valid TT 1-5 coverage by card+ history was 97%, 55%, 44%, 24% and 11%, respectively. Card retention rate for TT was 67%. The findings of this study revealed that access to child and TT immunizations were good. But high dropouts and invalid doses reduced these percentages of fully immunized child to 66%. Programmatic strategy must be undertaken to reduce the existing high dropout rate in both child and TT immunizations.

  12. Comparison of inflation of third dose diphtheria tetanus pertussis (DTP3) administrative coverage to other vaccine antigens.

    PubMed

    Dolan, Samantha B; MacNeil, Adam

    2017-06-14

    Third dose diphtheria tetanus pertussis (DTP3) administrative coverage is a commonly used indicator for immunization program performance, although studies have demonstrated data quality issues with administrative DTP3 coverage. It is possible that administrative coverage for DTP3 may be inflated more than for other antigens. To examine this, theory, we compiled immunization coverage estimates from recent country surveys (n=71) and paired these with corresponding administrative coverage estimates, by country and cohort year, for DTP3 and 4 other antigens. Median administrative coverage was higher than survey estimates of coverage for all antigens (median differences from 26 to 30%), however this difference was similar for DTP3 as for all other antigens. These findings were consistent when countries were stratified by income level and eligibility for Gavi funding. Our findings demonstrate that while country administrative coverage estimates tend to be higher than survey estimates, DTP3 administrative coverage is not inflated more than other antigens. Published by Elsevier Ltd.

  13. Quantifying the impact of immediate reconstruction in postmastectomy radiation: a large, dose-volume histogram-based analysis.

    PubMed

    Ohri, Nisha; Cordeiro, Peter G; Keam, Jennifer; Ballangrud, Ase; Shi, Weiji; Zhang, Zhigang; Nerbun, Claire T; Woch, Katherine M; Stein, Nicholas F; Zhou, Ying; McCormick, Beryl; Powell, Simon N; Ho, Alice Y

    2012-10-01

    To assess the impact of immediate breast reconstruction on postmastectomy radiation (PMRT) using dose-volume histogram (DVH) data. Two hundred forty-seven women underwent PMRT at our center, 196 with implant reconstruction and 51 without reconstruction. Patients with reconstruction were treated with tangential photons, and patients without reconstruction were treated with en-face electron fields and customized bolus. Twenty percent of patients received internal mammary node (IMN) treatment. The DVH data were compared between groups. Ipsilateral lung parameters included V20 (% volume receiving 20 Gy), V40 (% volume receiving 40 Gy), mean dose, and maximum dose. Heart parameters included V25 (% volume receiving 25 Gy), mean dose, and maximum dose. IMN coverage was assessed when applicable. Chest wall coverage was assessed in patients with reconstruction. Propensity-matched analysis adjusted for potential confounders of laterality and IMN treatment. Reconstruction was associated with lower lung V20, mean dose, and maximum dose compared with no reconstruction (all P<.0001). These associations persisted on propensity-matched analysis (all P<.0001). Heart doses were similar between groups (P=NS). Ninety percent of patients with reconstruction had excellent chest wall coverage (D95 >98%). IMN coverage was superior in patients with reconstruction (D95 >92.0 vs 75.7%, P<.001). IMN treatment significantly increased lung and heart parameters in patients with reconstruction (all P<.05) but minimally affected those without reconstruction (all P>.05). Among IMN-treated patients, only lower lung V20 in those without reconstruction persisted (P=.022), and mean and maximum heart doses were higher than in patients without reconstruction (P=.006, P=.015, respectively). Implant reconstruction does not compromise the technical quality of PMRT when the IMNs are untreated. Treatment technique, not reconstruction, is the primary determinant of target coverage and normal tissue doses. Published by Elsevier Inc.

  14. SU-F-T-395: Evaluation of Best Dosimetry Achievable with VMAT and IMRT Treatment Techniques Targeting Borderline Resectable Pancreatic Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harpool, K; Schnell, E; Herman, T

    Purpose: To determine from retrospective study the most appropriate technique for targeting small borderline operable pancreatic cancer surrounding blood vessels by evaluating the dosimetry and normal tissue sparing achievable using Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT). Methods: Treatment plans from ten patients who have undergone treatment with a prescribed dose of 4950 cGy, at 275 cGy per fraction, were analyzed. All plans were replanned using Eclipse TPS (Varian Medical Systems, Palo Alto, CA) with complementary VMAT or IMRT techniques to obtain paired data sets for comparison. The coverage to at least 95% of the plannedmore » target volume (PTV) was normalized to receive 100% of the prescription dose. The normal tissue constraints followed the quantitative analysis of normal tissue effects in the clinic (QUANTEC) guidelines and the organs at risks (OARs) were liver, kidneys, spinal cord and bowel. The plan evaluation was based on conformity index (CI), homogeneity index (HI), uniformity index (UI), DVH parameters, and student’s-t statistics (2 tails). Results: The VMAT technique delivered less maximum dose to the right kidney, left kidney, total kidney, liver, spinal cord, and bowel by 9.3%, 5.9%, 6.7%, 3.9%, 15.1%, 3.9%, and 4.3%, respectively. The averaged V15 for the total kidney was 10.21% for IMRT and 7.29% for VMAT. The averaged V20 for the bowel was 19.89% for IMRT and 14.06% for VMAT. On average, the CI for IMRT was 1.20 and 1.16 for VMAT (p = 0.20). The HI was 0.08 for both techniques (p = 0.91) and UI was 1.05 and 1.06 for IMRT and VMAT respectively (p = 0.59). Conclusion: Both techniques achieve adequate PTV coverage. Although VMAT techniques show better normal tissue sparing from excessive dose, no significant differences were observed. Slight discrepancies may rise from different versions of calculation algorithms.« less

  15. Mumps vaccine effectiveness and risk factors for disease in households during an outbreak in New York City.

    PubMed

    Livingston, Kara A; Rosen, Jennifer B; Zucker, Jane R; Zimmerman, Christopher M

    2014-01-09

    Mumps outbreaks have been reported among vaccinated populations, and declining mumps vaccine effectiveness (VE) has been suggested as one possible cause. During a large mumps outbreak in New York City, we assessed: (1) VE of measles-mumps-rubella vaccine (MMR) against mumps and (2) risk factors for acquiring mumps in households. Cases of mumps were investigated using standard methods. Additional information on disease and vaccination status of household contacts was collected. Case households completed follow-up phone interviews 78-198 days after initial investigation to ascertain additional cases. Mumps cases meeting the study case definition were included in the analysis. Risk factors for mumps were assessed, and VE was calculated using secondary household attack rates. Three hundred and eleven households with 2176 residents were included in the analysis. The median age of residents was 13 years (range <1-85), and 462 (21.2%) residents met the study mumps case definition. Among 7-17 year olds, 89.7% received one or more doses of MMR vaccine, with 76.7% receiving two doses. Young adults aged 10-14 years (OR=2.4, CI=1.3-4.7) and 15-19 years (OR=2.5, CI=1.3-5.0) were at highest risk of mumps. The overall 2-dose VE for secondary contacts aged five and older was 86.3% (CI 63.3-94.9). The two-dose effectiveness of MMR vaccine against mumps was 86.3%, consistent with other published mumps VE estimates. Many factors likely contributed to this outbreak. Suboptimal MMR coverage in the affected population combined with VE may not have conferred adequate immunity to prevent transmission and may have contributed to this outbreak. Achieving high MMR coverage remains the best available strategy for prevention of mumps outbreaks. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. SU-C-BRB-02: Automatic Planning as a Potential Strategy for Dose Escalation for Pancreas SBRT?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, S; Zheng, D; Ma, R

    Purpose: Stereotactic body radiation therapy (SBRT) has been suggested to provide high rates of local control for locally advanced pancreatic cancer. However, the close proximity of highly radiosensitive normal tissues usually causes the labor-intensive planning process, and may impede further escalation of the prescription dose. The present study evaluates the potential of an automatic planning system as a dose escalation strategy. Methods: Ten pancreatic cancer patients treated with SBRT were studied retrospectively. SBRT was delivered over 5 consecutive fractions with 6 ∼ 8Gy/fraction. Two plans were generated by Pinnacle Auto-Planning with the original prescription and escalated prescription, respectively. Escalated prescriptionmore » adds 1 Gy/fraction to the original prescription. Manually-created planning volumes were excluded in the optimization goals in order to assess the planning efficiency and quality simultaneously. Critical organs with closest proximity were used to determine the plan normalization to ensure the OAR sparing. Dosimetric parameters including D100, and conformity index (CI) were assessed. Results: Auto-plans directly generate acceptable plans for 70% of the cases without necessity of further improvement, and two more iterations at most are necessary for the rest of the cases. For the pancreas SBRT plans with the original prescription, autoplans resulted in favorable target coverage and PTV conformity (D100 = 96.3% ± 1.48%; CI = 0.88 ± 0.06). For the plans with the escalated prescriptions, no significant target under-dosage was observed, and PTV conformity remains reasonable (D100 = 93.3% ± 3.8%, and CI = 0.84 ± 0.05). Conclusion: Automatic planning, without substantial human-intervention process, results in reasonable PTV coverage and PTV conformity on the premise of adequate OAR sparing for the pancreas SBRT plans with escalated prescription. The results highlight the potential of autoplanning as a dose escalation strategy for pancreas SBRT treatment planning. Further investigations with a larger number of patients are necessary. The project is partially supported by Philips Medical Systems.« less

  17. Electron arc therapy for bilateral chest wall irradiation: treatment planning and dosimetric study.

    PubMed

    Sharma, P K; Jamema, S V; Kaushik, K; Budrukkar, A; Jalali, R; Deshpande, D D; Tambe, C M; Sarin, R; Munshi, A

    2011-04-01

    The treatment of patients with synchronous bilateral breast cancer is a challenge. We present a report of dosimetric data of patients with bilateral chest walls as the target treated with electron arc therapy. Ten consecutive patients who had undergone electron arc therapy to the bilateral chest wall for breast cancer were analysed. After positioning and immobilisation, patients underwent computed tomography scans from the neck to the upper abdomen. Electron arc plans were generated using the PLATO RTS (V1.8.2 Nucletron) treatment planning system. Electron energy was chosen depending upon the depth and thickness of the planning target volume (PTV). For all patients, the arc angle ranged between 80 and 280° (start angle 80°, stop angle 280°). The homogeneity index, coverage index and doses to organs at risk were evaluated. The patient-specific output factor and thermoluminescence dosimetry (TLD) measurements were carried out for all patients. The total planned dose to the PTV was 50Gy/25 fractions/5 weeks. The mean PTV (± standard deviation) was 568.9 (±116)cm(3). The mean PTV coverage was 89 (±5.8)% of the prescribed dose. For the right lung, the mean values of D(1) and D(10) were 46 (±7.6) and 30 (±9)Gy, respectively. For the left lung, the mean values of D(1) and D(10) were 45 (±7) and 27 (±8)Gy, respectively. For the heart, the mean values of D(1), D(5) and D(10) were 21 (±15), 13.5 (±12) and 9 (±9)Gy, respectively. The mean values of TLD at various pre-specified locations on the chest wall surface were 1.84, 1.82, 1.82, 1.89 and 1.78Gy, respectively The electron arc technique for treating the bilateral chest wall is a feasible and pragmatic technique. This technique has the twin advantages of adequate coverage of the target volume and sparing of adjacent normal structures. However, compared with other techniques, it needs a firm quality assurance protocol for dosimetry and treatment delivery. Copyright © 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  18. Critical appraisal of volumetric-modulated arc therapy compared with electrons for the radiotherapy of cutaneous Kaposi’s sarcoma of lower extremities with bone sparing

    PubMed Central

    Abraham, S; Fogliata, A; Jordaan, A; Clivio, A; Vanetti, E; Cozzi, L

    2013-01-01

    Objective: To evaluate the use of volumetric-modulated arc therapy [VMAT, RapidArc® (RA); Varian Medical Systems, Palo Alto, CA] for the treatment of cutaneous Kaposi’s sarcoma (KS) of lower extremities with adequate target coverage and high bone sparing, and to compare VMAT with electron beam therapy. Methods: 10 patients were planned with either RA or electron beams. The dose was prescribed to 30 Gy, 10 fractions, to mean the planning target volume (PTV), and significant maximum dose to bone was limited to 30 Gy. Plans were designed for 6-MV photon beams for RA and 6 MeV for electrons. Dose distributions were computed with AcurosXB® (Varian Medical Systems) for photons and with a Monte Carlo algorithm for electrons. Results: V90% was 97.3±1.2 for RA plans and 78.2±2.6 for electrons; similarly, V107% was 2.5±2.2 and 37.7±3.4, respectively. RA met coverage criteria. Concerning bone sparing, D2% was 29.6±1.1 for RA and 31.0±2.4 for electrons. Although acceptable for bone involvement, pronounced target coverage violations were obtained for electron plans. Monitor units were similar for electrons and RA, although for the latter they increased when superior bone sparing was imposed. Delivery times were 12.1±4.0 min for electrons and 4.8±1.3 min for the most modulated RA plans. Conclusion: High plan quality was shown for KS in the lower extremities using VMAT, and this might simplify their management in comparison with the more conventional usage of electrons, particularly in institutes with limited staff resources and heavy workloads. Advances in knowledge: VMAT is also dosimetrically extremely advantageous in a typology of treatments where electron beam therapy is mainly considered to be effective owing to the limited penetration of the beams. PMID:23392192

  19. Integration of comprehensive women's health programmes into health systems: cervical cancer prevention, care and control in Rwanda.

    PubMed

    Binagwaho, Agnes; Ngabo, Fidele; Wagner, Claire M; Mugeni, Cathy; Gatera, Maurice; Nutt, Cameron T; Nsanzimana, Sabin

    2013-09-01

    Although it is highly preventable and treatable, cervical cancer is the most common and most deadly cancer among women in Rwanda. By mobilizing a diverse coalition of partnerships, Rwanda became the first country in Africa to develop and implement a national strategic plan for cervical cancer prevention, screening and treatment. Rwanda - a small, landlocked nation in East Africa with a population of 10.4 million - is well positioned to tackle a number of "high-burden" noncommunicable diseases. The country's integrated response to infectious diseases has resulted in steep declines in premature mortality over the past decade. In 2011-2012, Rwanda vaccinated 227,246 girls with all three doses of the human papillomavirus (HPV) vaccine. Among eligible girls, three-dose coverage rates of 93.2% and 96.6% were achieved in 2011 and 2012, respectively. The country has also initiated nationwide screening and treatment programmes that are based on visual inspection of the cervix with acetic acid, testing for HPV DNA, cryotherapy, the loop electrosurgical excision procedure and various advanced treatment options. Low-income countries should begin to address cervical cancer by integrating prevention, screening and treatment into routine women's health services. This requires political will, cross-sectoral collaboration and planning, innovative partnerships and robust monitoring and evaluation. With external support and adequate planning, high nationwide coverage rates for HPV vaccination and screening for cervical cancer can be achieved within a few years.

  20. MO-FG-CAMPUS-TeP2-04: Optimizing for a Specified Target Coverage Probability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fredriksson, A

    2016-06-15

    Purpose: The purpose of this work is to develop a method for inverse planning of radiation therapy margins. When using this method the user specifies a desired target coverage probability and the system optimizes to meet the demand without any explicit specification of margins to handle setup uncertainty. Methods: The method determines which voxels to include in an optimization function promoting target coverage in order to achieve a specified target coverage probability. Voxels are selected in a way that retains the correlation between them: The target is displaced according to the setup errors and the voxels to include are selectedmore » as the union of the displaced target regions under the x% best scenarios according to some quality measure. The quality measure could depend on the dose to the considered structure alone or could depend on the dose to multiple structures in order to take into account correlation between structures. Results: A target coverage function was applied to the CTV of a prostate case with prescription 78 Gy and compared to conventional planning using a DVH function on the PTV. Planning was performed to achieve 90% probability of CTV coverage. The plan optimized using the coverage probability function had P(D98 > 77.95 Gy) = 0.97 for the CTV. The PTV plan using a constraint on minimum DVH 78 Gy at 90% had P(D98 > 77.95) = 0.44 for the CTV. To match the coverage probability optimization, the DVH volume parameter had to be increased to 97% which resulted in 0.5 Gy higher average dose to the rectum. Conclusion: Optimizing a target coverage probability is an easily used method to find a margin that achieves the desired coverage probability. It can lead to reduced OAR doses at the same coverage probability compared to planning with margins and DVH functions.« less

  1. Socio-economic determinants and inequities in coverage and timeliness of early childhood immunisation in rural Ghana.

    PubMed

    Gram, Lu; Soremekun, Seyi; ten Asbroek, Augustinus; Manu, Alexander; O'Leary, Maureen; Hill, Zelee; Danso, Samuel; Amenga-Etego, Seeba; Owusu-Agyei, Seth; Kirkwood, Betty R

    2014-07-01

    To assess the extent of socio-economic inequity in coverage and timeliness of key childhood immunisations in Ghana. Secondary analysis of vaccination card data collected from babies born between January 2008 and January 2010 who were registered in the surveillance system supporting the ObaapaVita and Newhints Trials was carried out. 20 251 babies had 6 weeks' follow-up, 16 652 had 26 weeks' follow-up, and 5568 had 1 year's follow-up. We performed a descriptive analysis of coverage and timeliness of vaccinations by indicators for urban/rural status, wealth and educational attainment. The association of coverage with socio-economic indicators was tested using a chi-square-test and the association with timeliness using Cox regression. Overall coverage at 1 year of age was high (>95%) for Bacillus Calmette-Guérin (BCG), all three pentavalent diphtheria-pertussis-tetanus-haemophilus influenzae B-hepatitis B (DPTHH) doses and all polio doses except polio at birth (63%). Coverage against measles and yellow fever was 85%. Median delay for BCG was 1.7 weeks. For polio at birth, the median delay was 5 days; all other vaccine doses had median delays of 2-4 weeks. We found substantial health inequity across all socio-economic indicators for all vaccines in terms of timeliness, but not coverage at 1 year. For example, for the last DPTHH dose, the proportion of children delayed more than 8 weeks were 27% for urban children and 31% for rural children (P < 0.001), 21% in the wealthiest quintile and 41% in the poorest quintile (P < 0.001), and 9% in the most educated group and 39% in the least educated group (P < 0.001). However, 1-year coverage of the same dose remained above 90% for all levels of all socio-economic indicators. Ghana has substantial health inequity across urban/rural, socio-economic and educational divides. While overall coverage was high, most vaccines suffered from poor timeliness. We suggest that countries achieving high coverage should include timeliness indicators in their surveillance systems. © 2014 John Wiley & Sons Ltd.

  2. Insuring Your Property. The CIRcular: Consumer Information Report 29.

    ERIC Educational Resources Information Center

    Bank of America NT & SA, San Francisco, CA.

    This report presents guidelines to help homeowners, renters, and condominium owners purchase and maintain adequate insurance coverage for their residences and personal property. Types of property coverage discussed include the following: (1) standard policies and exclusions; (2) special programs (earthquake insurance, federal programs for…

  3. A novel dose-based positioning method for CT image-guided proton therapy

    PubMed Central

    Cheung, Joey P.; Park, Peter C.; Court, Laurence E.; Ronald Zhu, X.; Kudchadker, Rajat J.; Frank, Steven J.; Dong, Lei

    2013-01-01

    Purpose: Proton dose distributions can potentially be altered by anatomical changes in the beam path despite perfect target alignment using traditional image guidance methods. In this simulation study, the authors explored the use of dosimetric factors instead of only anatomy to set up patients for proton therapy using in-room volumetric computed tomographic (CT) images. Methods: To simulate patient anatomy in a free-breathing treatment condition, weekly time-averaged four-dimensional CT data near the end of treatment for 15 lung cancer patients were used in this study for a dose-based isocenter shift method to correct dosimetric deviations without replanning. The isocenter shift was obtained using the traditional anatomy-based image guidance method as the starting position. Subsequent isocenter shifts were established based on dosimetric criteria using a fast dose approximation method. For each isocenter shift, doses were calculated every 2 mm up to ±8 mm in each direction. The optimal dose alignment was obtained by imposing a target coverage constraint that at least 99% of the target would receive at least 95% of the prescribed dose and by minimizing the mean dose to the ipsilateral lung. Results: The authors found that 7 of 15 plans did not meet the target coverage constraint when using only the anatomy-based alignment. After the authors applied dose-based alignment, all met the target coverage constraint. For all but one case in which the target dose was met using both anatomy-based and dose-based alignment, the latter method was able to improve normal tissue sparing. Conclusions: The authors demonstrated that a dose-based adjustment to the isocenter can improve target coverage and/or reduce dose to nearby normal tissue. PMID:23635262

  4. Utilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment.

    PubMed

    Paluska, Petr; Hanus, Josef; Sefrova, Jana; Rouskova, Lucie; Grepl, Jakub; Jansa, Jan; Kasaova, Linda; Hodek, Miroslav; Zouhar, Milan; Vosmik, Milan; Petera, Jiri

    2012-01-01

    To assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction. Implementation of IGRT should influence safety margins. Utilization of cone-beam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution. Seventeen prostate patients were treated with daily bony anatomy image-guidance. Cone-beam CT (CBCT) scans were acquired once a week immediately after bony anatomy alignment. After the prostate, seminal vesicles, rectum and bladder were contoured, the delivered dose distribution was reconstructed. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed a 1 cm safety margin. Alternative plans assuming a smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with the initial ones. Rectal and bladder volumes irradiated with doses higher than 75 Gy, 70 Gy, 60 Gy, 50 Gy and 40 Gy were analyzed. In 12% of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5 patients. Coverage of seminal vesicles was not satisfactory in 3% of plans. Most of the target underdosage corresponded to excessive rectal or bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22% and 11% of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively. Sufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety margin is not acceptable. Initial rectal and bladder volumes cannot be considered representative for subsequent treatment.

  5. Human papillomavirus vaccination coverage in Luxembourg - Implications of lowering and restricting target age groups.

    PubMed

    Latsuzbaia, Ardashel; Arbyn, Marc; Weyers, Steven; Mossong, Joël

    2018-04-25

    In Luxembourg, a national Human Papillomavirus (HPV) vaccination programme was introduced in 2008, targeting 12-17 year old girls offering a choice of bivalent or quadrivalent vaccine free of charge. In 2015, the programme was changed offering the bivalent vaccine only to 11-13 year old girls. The aim of this study was to evaluate the HPV vaccination coverage, to assess the impact of age target changes and compare vaccination coverage to other European countries. Anonymous HPV vaccination records consisting of individual vaccine doses obtained free of charge in pharmacies between 2008 and 2016 were extracted from the Luxembourgish Social Security database. Additional aggregate tables by nationality and municipality were analysed. Of the target cohort of 39,610 girls born between 1991 and 2003 residing in Luxembourg, 24,550 (62.0%) subjects obtained at least one dose, 22,082 (55.7%) obtained at least two doses, and 17,197 (43.4%) obtained three doses of HPV vaccine. The mean age at first dose was 13.7 years during 2008-14 and 12.7 years in 2016 after the age target change. Coverage varied significantly by nationality (p < 0.0001): Portuguese (80%), former Yugoslavs (74%), Luxembourgish (54%), Belgian (52%), German (47%), French (39%) and other nationalities (51%). Coverage varied also by geographical region, with lower rates (<50%) noted in some Northern and Central areas of Luxembourg (range: 38% to 78%). Overall HPV vaccination coverage in Luxembourg is moderate and varied by nationality and region. The policy changes in 2015 did not have a substantial impact except lowering age at initiating vaccination. Options to improve coverage deserve further investigation. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  6. Modelling the impact of a combined varicella and zoster vaccination programme on the epidemiology of varicella zoster virus in England.

    PubMed

    van Hoek, Albert Jan; Melegaro, Alessia; Zagheni, Emelio; Edmunds, W John; Gay, Nigel

    2011-03-16

    This study updates previous work on modelling the incidence of varicella and Herpes Zoster (HZ) following the introduction of childhood vaccination. The updated model includes new data on age-specific contact patterns, as well as data on the efficacy of zoster vaccination in the elderly and allows for HZ among vaccinees. The current study also looks at two-dose varicella childhood programmes, and assesses the combined impact of varicella vaccination in childhood and zoster vaccination of the elderly. The results suggest that a two-dose schedule is likely to reduce the incidence of varicella to very low levels, provided first dose coverage is around 90% and second dose coverage is in excess of 70%. Single dose varicella vaccination programmes are expected to result in large numbers of breakthrough cases. Childhood vaccination is expected to increase the incidence of zoster for more than 40 years after introduction of the programme, the magnitude of this increase being influenced primarily by the duration of boosting following exposure to the varicella zoster virus. Though this increase in zoster incidence can be partly offset by vaccination of the elderly, the effectiveness of this combined strategy is limited, as much of the increase occurs in those adults too young to be vaccinated. Childhood vaccination at intermediate levels of coverage (70% and 60% for first and second dose coverage respectively) is expected to lead to an increase in adult varicella. At high coverage (90% and 80% coverage) this is unlikely to be the case. These results will be used to inform a cost-effectiveness analysis of combined varicella and zoster vaccination programmes. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Survey of distribution of seasonal influenza vaccine doses in 201 countries (2004-2015): The 2003 World Health Assembly resolution on seasonal influenza vaccination coverage and the 2009 influenza pandemic have had very little impact on improving influenza control and pandemic preparedness.

    PubMed

    Palache, A; Abelin, A; Hollingsworth, R; Cracknell, W; Jacobs, C; Tsai, T; Barbosa, P

    2017-08-24

    There is no global monitoring system for influenza vaccination coverage, making it difficult to assess progress towards the 2003 World Health Assembly (WHA) vaccination coverage target. In 2008, the IFPMA Influenza Vaccine Supply International Task Force (IVS) developed a survey method to assess the global distribution of influenza vaccine doses as a proxy for vaccination coverage rates. The latest dose distribution data for 2014 and 2015 was used to update previous analyses. Data were confidentially collected and aggregated by the IFPMA Secretariat, and combined with previous IFPMA IVS survey data (2004-2013). Data were available from 201 countries over the 2004-2015 period. A "hurdle" rate was defined as the number of doses required to reach 15.9% of the population in 2008. Overall, the number of distributed doses progressively increased between 2004 and 2011, driven by a 150% increase in AMRO, then plateaued. One percent fewer doses were distributed in 2015 than in 2011. Twenty-three countries were above the hurdle rate in 2015, compared to 15 in 2004, but distribution was highly uneven in and across all WHO regions. Three WHO regions (AMRO, EURO and WPRO) accounted for about 95% of doses distributed. But in EURO and WPRO, distribution rates in 2015 were only marginally higher than in 2004, and in EURO there was an overall downward trend in dose distribution. The vast majority of countries cannot meet the 2003WHA coverage targets and are inadequately prepared for a global influenza pandemic. With only 5% of influenza vaccine doses being distributed to 50% of the world's population, there is urgency to redress the gross inequities in disease prevention and in pandemic preparedness. The 2003WHA resolution must be reviewed and revised and a call issued for the renewed commitment of Member States to influenza vaccination coverage targets. Copyright © 2017. Published by Elsevier Ltd.

  8. Vaccination coverage according to doses received and timely administered based on an electronic immunization registry, Araraquara-SP, Brazil, 2012-2014.

    PubMed

    Tauil, Márcia de Cantuária; Sato, Ana Paula Sayuri; Costa, Ângela Aparecida; Inenami, Marta; Ferreira, Vinícius Leati de Rossi; Waldman, Eliseu Alves

    2017-01-01

    to describe vaccine coverage by type of vaccine at 12 and 24 months of age. descriptive cohort study with children born in 2012, living in Araraquara-SP, Brazil, recorded in the Information System on Live Births (Sinasc); a manual linkage of Sinasc data with an electronic immunization registry (EIR) was performed; the assessment was based on vaccination status according to São Paulo State recommendations, and on doses received and timely administered. 2,740 children were registered on Sinasc and 99.6% of them were included into EIR; among the 2,612 (95.3%) children studied, the triple viral vaccine (measles, mumps and rubella) had the lowest coverage at 12 months for received dose (74.8%) and at 24 months for timely vaccination (53.5%) and received doses (88.0%). coverage was higher than 90% for most vaccines; however, delayed vaccination was observed, which indicates the need to intensify actions aimed at timely vaccination.

  9. A review of measles supplementary immunization activities and the implications for Pacific Island countries and territories.

    PubMed

    Clements, C John; Soakai, Taniela Sunia; Sadr-Azodi, Nahad

    2017-02-01

    Standard measles control strategies include achieving high levels of measles vaccine coverage using routine delivery systems, supplemented by mass immunization campaigns as needed to close population immunity gaps. Areas covered: This review looks at how supplementary immunization activities (SIAs) have contributed to measles control globally, and asks whether such a strategy has a place in Pacific Islands today. Expert commentary: Very high coverage with two doses of measles vaccine seems to be the optimal strategy for controlling measles. By 2015, all but two Pacific Islands had introduced a second dose in the routine schedule; however, a number of countries have not yet reached high coverage with their second dose. The literature and the country reviews reported here suggest that a high coverage SIA combined with one dose of measles vaccine given in the routine system will also do the job. The arguments for and against the use of SIAs are complex, but it is clear that to be effective, SIAs need to be well designed to meet specific needs, must be carried out effectively and safely with very high coverage, and should, when possible, carry with them other public health interventions to make them even more cost-effective.

  10. Evaluation of Emergency Department Management of Opioid-Tolerant Cancer Patients With Acute Pain.

    PubMed

    Patel, Pina M; Goodman, Lauren F; Knepel, Sheri A; Miller, Charles C; Azimi, Asma; Phillips, Gary; Gustin, Jillian L; Hartman, Amber

    2017-10-01

    There are no previously published studies examining opioid doses administered to opioid-tolerant cancer patients during emergency department (ED) encounters. To determine if opioid-tolerant cancer patients presenting with acute pain exacerbations receive adequate initial doses of as needed (PRN) opioids during ED encounters based on home oral morphine equivalent (OME) use. We performed a retrospective cohort study of opioid-tolerant cancer patients who received opioids in our ED over a two-year period. The percentage of patients who received an adequate initial dose of PRN opioid (defined as ≥10% of total 24-hour ambulatory OME) was evaluated. Logistic regression was used to establish the relationship between 24-hour ambulatory OME and initial ED OME to assess whether higher home usage was associated with higher likelihood of being undertreated. Out of 216 patients, 61.1% of patients received an adequate initial PRN dose of opioids in the ED. Of patients taking <200 OMEs per day at home, 77.4% received an adequate initial dose; however, only 3.2% of patients taking >400 OMEs per day at home received an adequate dose. Patients with ambulatory 24-hour OME greater than 400 had 99% lower odds of receiving an adequate initial dose of PRN opioid in the ED compared to patients with ambulatory 24-hour OME less than 100 (OR <0.01, CI 0.00-0.02, P < 0.001). Patients with daily home use less than 200 OMEs generally received adequate initial PRN opioid doses during their ED visit. However, patients with higher home opioid usage were at increased likelihood of being undertreated. Copyright © 2017 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  11. SU-F-T-204: A Preliminary Approach of Reducing Contralateral Breast and Heart Dose in Left Sided Whole Breast Cancer Patients Utilizing Proton Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Islam, M; Algan, O; Jin, H

    Purpose: To investigate the plan quality and feasibility of a hybrid plan utilizing proton and photon fields for superior coverage in the internal mammary (IM) and supraclavicular (S/C) regions while minimizing heart and contralateral breast dose for the left-sided whole breast cancer patient treatment. Methods: This preliminary study carried out on single left-sided intact breast patient involved IM and S/C nodes. The IM and S/C node fields of the 5-Field 3DCRT photon-electron base plan were replaced by two proton fields. These two along with two Field-in-Field tangential photon fields were optimized for comparable dose coverage. The treatment plans were donemore » using Eclipse TPS for the total dose of 46Gy in 23 fractions with 95% of the prescription dose covering 95% of the RTOG PTV. The 3DCRT photon-electron and 4-Field photon-proton hybrid plans were compared for the PTV dose coverage as well as dose to OARs. Results: The overall RTOG PTV coverage for proton-hybrid and 3DCRT plan was comparable (95% of prescription dose covers 95% PTV volume). In proton-hybrid plan, 99% of IM volume received 100% dose whereas in 3DCRT only 77% received 100% dose. For S/C regions, 97% and 77% volume received 100% prescription dose in proton-hybrid and 3DCRT plans, respectively. The heart mean dose, V3Gy(%), and V5Gy(%) was 2.2Gy, 14.4%, 9.8% for proton-hybrid vs. 4.20 Gy, 21.5%, and 39% for 3DCRT plan, respectively. The maximum dose to the contralateral breast was 39.75Gy for proton-hybrid while 56.87Gy for 3DCRT plan. The mean total lung dose, V20Gy(%), and V30Gy(%) was 5.68Gy, 11.3%, 10.5% for proton-hybrid vs. 5.90Gy, 9.8%, 7.2% for 3DCRT, respectively. Conclusion: The protonhybrid plan can offer better dose coverage to the involved lymphatic tissues while lower doses to the heart and contralateral breast. More treatment plans are currently in progress before being implemented clinically.« less

  12. Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ali, Imad, E-mail: iali@ouhsc.edu; Ahmad, Salahuddin

    2013-10-01

    To compare the doses calculated using the BrainLAB pencil beam (PB) and Monte Carlo (MC) algorithms for tumors located in various sites including the lung and evaluate quality assurance procedures required for the verification of the accuracy of dose calculation. The dose-calculation accuracy of PB and MC was also assessed quantitatively with measurement using ionization chamber and Gafchromic films placed in solid water and heterogeneous phantoms. The dose was calculated using PB convolution and MC algorithms in the iPlan treatment planning system from BrainLAB. The dose calculation was performed on the patient's computed tomography images with lesions in various treatmentmore » sites including 5 lungs, 5 prostates, 4 brains, 2 head and necks, and 2 paraspinal tissues. A combination of conventional, conformal, and intensity-modulated radiation therapy plans was used in dose calculation. The leaf sequence from intensity-modulated radiation therapy plans or beam shapes from conformal plans and monitor units and other planning parameters calculated by the PB were identical for calculating dose with MC. Heterogeneity correction was considered in both PB and MC dose calculations. Dose-volume parameters such as V95 (volume covered by 95% of prescription dose), dose distributions, and gamma analysis were used to evaluate the calculated dose by PB and MC. The measured doses by ionization chamber and EBT GAFCHROMIC film in solid water and heterogeneous phantoms were used to quantitatively asses the accuracy of dose calculated by PB and MC. The dose-volume histograms and dose distributions calculated by PB and MC in the brain, prostate, paraspinal, and head and neck were in good agreement with one another (within 5%) and provided acceptable planning target volume coverage. However, dose distributions of the patients with lung cancer had large discrepancies. For a plan optimized with PB, the dose coverage was shown as clinically acceptable, whereas in reality, the MC showed a systematic lack of dose coverage. The dose calculated by PB for lung tumors was overestimated by up to 40%. An interesting feature that was observed is that despite large discrepancies in dose-volume histogram coverage of the planning target volume between PB and MC, the point doses at the isocenter (center of the lesions) calculated by both algorithms were within 7% even for lung cases. The dose distributions measured with EBT GAFCHROMIC films in heterogeneous phantoms showed large discrepancies of nearly 15% lower than PB at interfaces between heterogeneous media, where these lower doses measured by the film were in agreement with those by MC. The doses (V95) calculated by MC and PB agreed within 5% for treatment sites with small tissue heterogeneities such as the prostate, brain, head and neck, and paraspinal tumors. Considerable discrepancies, up to 40%, were observed in the dose-volume coverage between MC and PB in lung tumors, which may affect clinical outcomes. The discrepancies between MC and PB increased for 15 MV compared with 6 MV indicating the importance of implementation of accurate clinical treatment planning such as MC. The comparison of point doses is not representative of the discrepancies in dose coverage and might be misleading in evaluating the accuracy of dose calculation between PB and MC. Thus, the clinical quality assurance procedures required to verify the accuracy of dose calculation using PB and MC need to consider measurements of 2- and 3-dimensional dose distributions rather than a single point measurement using heterogeneous phantoms instead of homogenous water-equivalent phantoms.« less

  13. SU-E-T-318: The Effect of Patient Positioning Errors On Target Coverage and Cochlear Dose in Stereotactic Radiosurgery Treatment of Acoustic Neuromas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dellamonica, D.; Luo, G.; Ding, G.

    Purpose: Setup errors on the order of millimeters may cause under-dosing of targets and significant changes in dose to critical structures especially when planning with tight margins in stereotactic radiosurgery. This study evaluates the effects of these types of patient positioning uncertainties on planning target volume (PTV) coverage and cochlear dose for stereotactic treatments of acoustic neuromas. Methods: Twelve acoustic neuroma patient treatment plans were retrospectively evaluated in Brainlab iPlan RT Dose 4.1.3. All treatment beams were shaped by HDMLC from a Varian TX machine. Seven patients had planning margins of 2mm, five had 1–1.5mm. Six treatment plans were createdmore » for each patient simulating a 1mm setup error in six possible directions: anterior-posterior, lateral, and superiorinferior. The arcs and HDMLC shapes were kept the same for each plan. Change in PTV coverage and mean dose to the cochlea was evaluated for each plan. Results: The average change in PTV coverage for the 72 simulated plans was −1.7% (range: −5 to +1.1%). The largest average change in coverage was observed for shifts in the patient's superior direction (−2.9%). The change in mean cochlear dose was highly dependent upon the direction of the shift. Shifts in the anterior and superior direction resulted in an average increase in dose of 13.5 and 3.8%, respectively, while shifts in the posterior and inferior direction resulted in an average decrease in dose of 17.9 and 10.2%. The average change in dose to the cochlea was 13.9% (range: 1.4 to 48.6%). No difference was observed based on the size of the planning margin. Conclusion: This study indicates that if the positioning uncertainty is kept within 1mm the setup errors may not result in significant under-dosing of the acoustic neuroma target volumes. However, the change in mean cochlear dose is highly dependent upon the direction of the shift.« less

  14. Evaluation of a poliomyelitis immunization campaign in Madras city.

    PubMed

    Balraj, V; John, T J

    1986-01-01

    An annual pulse immunization campaign with oral polio vaccine (OPV) was evaluated to determine vaccine coverage, relative success of publicity methods and reasons for lack of response. The campaign was directed at 3-36 month olds in Madras city, India, in January-March 1985. The evaluation method was the "30-cluster" sample survey technique, designed by WHO, where surveys were done in 30 districts of the city on 10 children in each age group. The survey was conducted in April 1985 by 5 trained and supervised interviewers. This campaign increased the vaccine coverage to 94%, 88% and 72% for first, second and third doses of OPV. Coverage was higher in older children. Percent coverage decreased slightly over 1-3 doses, and from there rapidly up to 6-7 doses. The campaign accounted for 27% of all the OPV the study children had received. 47% of parents heard about the vaccination through word of mouth, either from health workers, volunteers or "balwadi ayahs," women day-care workers. 17% learned through television or radio. 3% cited mobile loudspeakers, handbills, posters or slides in cinemas. Many parents did not avail themselves of the vaccine because they believed that 3 doses are sufficient. Actually the WHO recommends 4 doses; the Indian Academy of Pediatrics recommends 5 doses; while criteria from research on Indian children would suggest that 5-7 doses are required to raise strong immunity.

  15. Daily and Nondaily Oral Preexposure Prophylaxis in Men and Transgender Women Who Have Sex With Men: The Human Immunodeficiency Virus Prevention Trials Network 067/ADAPT Study.

    PubMed

    Grant, Robert M; Mannheimer, Sharon; Hughes, James P; Hirsch-Moverman, Yael; Loquere, Avelino; Chitwarakorn, Anupong; Curlin, Marcel E; Li, Maoji; Amico, K Rivet; Hendrix, Craig W; Anderson, Peter L; Dye, Bonnie J; Marzinke, Mark A; Piwowar-Manning, Estelle; McKinstry, Laura; Elharrar, Vanessa; Stirratt, Michael; Rooney, James F; Eshleman, Susan H; McNicholl, Janet M; van Griensven, Frits; Holtz, Timothy H

    2018-05-17

    Nondaily dosing of oral preexposure prophylaxis (PrEP) may provide equivalent coverage of sex events compared with daily dosing. At-risk men and transgender women who have sex with men were randomly assigned to 1 of 3 dosing regimens: 1 tablet daily, 1 tablet twice weekly with a postsex dose (time-driven), or 1 tablet before and after sex (event-driven), and were followed for coverage of sex events with pre- and postsex dosing measured by weekly self-report, drug concentrations, and electronic drug monitoring. From July 2012 to May 2014, 357 participants were randomized. In Bangkok, the coverage of sex events was 85% for the daily arm compared with 84% for the time-driven arm (P = .79) and 74% for the event-driven arm (P = .02). In Harlem, coverage was 66%, 47% (P = .01), and 52% (P = .01) for these groups. In Bangkok, PrEP medication concentrations in blood were consistent with use of ≥2 tablets per week in >95% of visits when sex was reported in the prior week, while in Harlem, such medication concentrations occurred in 48.5% in the daily arm, 30.9% in the time-driven arm, and 16.7% in the event-driven arm (P < .0001). Creatinine elevations were more common in the daily arm (P = .050), although they were not dose limiting. Daily dosing recommendations increased coverage and protective drug concentrations in the Harlem cohort, while daily and nondaily regimens led to comparably favorable outcomes in Bangkok, where participants had higher levels of education and employment. NCT01327651.

  16. Immunization rates and timely administration in pre-school and school-aged children.

    PubMed

    Heininger, Ulrich; Zuberbühler, Mirjam

    2006-02-01

    Whereas immunization coverage has been repeatedly assessed in the Swiss population, little is known about the timely administration of universally recommended immunizations in Switzerland and elsewhere. The goal of this study was to determine compliance with official standard immunization recommendations in pre-school and school-aged children in Basel, Switzerland, focusing on coverage rates and timely administration. Of a cohort of children entering kindergarten and third-grade primary school in Basel in 2001, 310 and 310, respectively, were identified in proportion to the overall age-appropriate populations in the four city districts. Foreign-born children were excluded. The data were extracted from immunization records provided voluntarily by parents. Coverage for three doses of diphtheria, tetanus, and poliomyelitis vaccines was >95% and <90% for pertussis and Hib. The rates of age-appropriate booster doses were significantly lower, especially for pertussis and Hib (<60%). Cumulative coverage for measles, mumps, and rubella (MMR) was <90% for the first dose and 33% for the second dose by 10 years of age. All immunizations were administered with significant delays. Coverage for the first three doses of DTP combination vaccines did not reach 90% before 1 year of age and, for the first dose of MMR, a plateau just below 80% was not reached before 3 years of age. Delayed administration of immunizations in childhood, as well as complete lack of booster doses in a significant fraction of children, with important implications for public health have been discovered in this study. This may lead to fatal disease in individuals, epidemics in the community, and threatens national and international targets of disease elimination, such as measles and congenital rubella syndrome.

  17. Role of step size and max dwell time in anatomy based inverse optimization for prostate implants

    PubMed Central

    Manikandan, Arjunan; Sarkar, Biplab; Rajendran, Vivek Thirupathur; King, Paul R.; Sresty, N.V. Madhusudhana; Holla, Ragavendra; Kotur, Sachin; Nadendla, Sujatha

    2013-01-01

    In high dose rate (HDR) brachytherapy, the source dwell times and dwell positions are vital parameters in achieving a desirable implant dose distribution. Inverse treatment planning requires an optimal choice of these parameters to achieve the desired target coverage with the lowest achievable dose to the organs at risk (OAR). This study was designed to evaluate the optimum source step size and maximum source dwell time for prostate brachytherapy implants using an Ir-192 source. In total, one hundred inverse treatment plans were generated for the four patients included in this study. Twenty-five treatment plans were created for each patient by varying the step size and maximum source dwell time during anatomy-based, inverse-planned optimization. Other relevant treatment planning parameters were kept constant, including the dose constraints and source dwell positions. Each plan was evaluated for target coverage, urethral and rectal dose sparing, treatment time, relative target dose homogeneity, and nonuniformity ratio. The plans with 0.5 cm step size were seen to have clinically acceptable tumor coverage, minimal normal structure doses, and minimum treatment time as compared with the other step sizes. The target coverage for this step size is 87% of the prescription dose, while the urethral and maximum rectal doses were 107.3 and 68.7%, respectively. No appreciable difference in plan quality was observed with variation in maximum source dwell time. The step size plays a significant role in plan optimization for prostate implants. Our study supports use of a 0.5 cm step size for prostate implants. PMID:24049323

  18. SU-E-T-615: Plan Comparison Between Photon IMRT and Proton Plans Incorporating Uncertainty Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, C; Wessels, B; Jesseph, F

    2015-06-15

    Purpose: In this study, we investigate the effect of setup uncertainty on DVH calculations which may impact plan comparison. Methods: Treatment plans (6 MV VMAT calculated on Pinnacle TPS) were chosen for different disease sites: brain, prostate, H&N and spine in this retrospective study. A proton plan (PP) using double scattering beams was generated for each selected VMAT plan subject to the same set of dose-volume constraints as in VMAT. An uncertainty analysis was incorporated on the DVH calculations in which isocenter shifts from 1 to 5 mm in each of the ±x, ±y and ±z directions were used tomore » simulate the setup uncertainty and residual positioning errors. A total of 40 different combinations of isocenter shifts were used in the re-calculation of DVH of the PTV and the various OARs for both the VMAT and the corresponding PT. Results: For the brain case, both VMAT and PP are comparable in PTV coverage and OAR sparing, and VMAT is a clear choice for treatment due to its ease of delivery. However, when incorporating isoshifts in DVH calculations, a significant change in dose-volume relationship emerges. For example, both VMAT and PT provide adequate coverage, even with ±3mm isoshift. However, +3mm isoshift results in increase of V40(Lcochlea, VMAT) from 7.2% in the original plan to 45% and V40(R cochlea, VMAT) from 75% to 92%. For protons, V40(Lcochlea, PT) increases from 62% in the initial plan to 75%, while V40(Rcochea, PT) increases from 7% to 26%. Conclusion: DVH alone may not be sufficient to allow an unequivocal decision in plan comparison, especially when two rival plans are very similar in both PTV coverage and OAR sparing. It is a good practice to incorporate uncertainty analysis on photon and proton plan comparison studies to test the plan robustness in plan evaluation.« less

  19. Human papillomavirus (HPV) vaccine coverage achievements in low and middle-income countries 2007-2016.

    PubMed

    Gallagher, Katherine E; Howard, Natasha; Kabakama, Severin; Mounier-Jack, Sandra; Burchett, Helen E D; LaMontagne, D Scott; Watson-Jones, Deborah

    2017-12-01

    Since 2007, HPV vaccine has been available to low and middle income countries (LAMIC) for small-scale 'demonstration projects', or national programmes. We analysed coverage achieved in HPV vaccine demonstration projects and national programmes that had completed at least 6 months of implementation between January 2007-2016. A mapping exercise identified 45 LAMICs with HPV vaccine delivery experience. Estimates of coverage and factors influencing coverage were obtained from 56 key informant interviews, a systematic published literature search of 5 databases that identified 61 relevant full texts and 188 solicited unpublished documents, including coverage surveys. Coverage achievements were analysed descriptively against country or project/programme characteristics. Heterogeneity in data, funder requirements, and project/programme design precluded multivariate analysis. Estimates of uptake, schedule completion rates and/or final dose coverage were available from 41 of 45 LAMICs included in the study. Only 17 estimates from 13 countries were from coverage surveys, most were administrative data. Final dose coverage estimates were all over 50% with most between 70% and 90%, and showed no trend over time. The majority of delivery strategies included schools as a vaccination venue. In countries with school enrolment rates below 90%, inclusion of strategies to reach out-of-school girls contributed to obtaining high coverage compared to school-only strategies. There was no correlation between final dose coverage and estimated recurrent financial costs of delivery from cost analyses. Coverage achieved during joint delivery of HPV vaccine combined with another intervention was variable with little/no evaluation of the correlates of success. This is the most comprehensive descriptive analysis of HPV vaccine coverage in LAMICs to date. It is possible to deliver HPV vaccine with excellent coverage in LAMICs. Further good quality data are needed from health facility based delivery strategies and national programmes to aid policymakers to effectively and sustainably scale-up HPV vaccination. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  20. Maintaining high rates of measles immunization in Africa.

    PubMed

    Lessler, J; Moss, W J; Lowther, S A; Cummings, D A T

    2011-07-01

    Supplementary immunization activities (SIAs) are important in achieving high levels of population immunity to measles virus. Using data from a 2006 survey of measles vaccination in Lusaka, Zambia, we developed a model to predict measles immunity following routine vaccination and SIAs, and absent natural infection. Projected population immunity was compared between the current programme and alternatives, including supplementing routine vaccination with a second dose, or SIAs at 1-, 2-, 3-, 4- and 5-year intervals. Current routine vaccination plus frequent SIAs could maintain high levels of population immunity in children aged <5 years, even if each frequent SIA has low coverage (e.g. ≥ 72% for bi-annual 60% coverage SIAs vs. ≥ 69% for quadrennial 95% coverage SIAs). A second dose at 12 months with current coverage could achieve 81% immunity. Circulating measles virus will only increase population immunity. Public health officials should consider frequent SIAs when resources for a two-dose strategy are unavailable.

  1. Effective coverage of essential inpatient care for small and sick newborns in a high mortality urban setting: a cross-sectional study in Nairobi City County, Kenya.

    PubMed

    Murphy, Georgina A V; Gathara, David; Mwachiro, Jacintah; Abuya, Nancy; Aluvaala, Jalemba; English, Mike

    2018-05-22

    Effective coverage requires that those in need can access skilled care supported by adequate resources. There are, however, few studies of effective coverage of facility-based neonatal care in low-income settings, despite the recognition that improving newborn survival is a global priority. We used a detailed retrospective review of medical records for neonatal admissions to public, private not-for-profit (mission) and private-for-profit (private) sector facilities providing 24×7 inpatient neonatal care in Nairobi City County to estimate the proportion of small and sick newborns receiving nationally recommended care across six process domains. We used our findings to explore the relationship between facility measures of structure and process and estimate effective coverage. Of 33 eligible facilities, 28 (four public, six mission and 18 private), providing an estimated 98.7% of inpatient neonatal care in the county, agreed to partake. Data from 1184 admission episodes were collected. Overall performance was lowest (weighted mean score 0.35 [95% confidence interval or CI: 0.22-0.48] out of 1) for correct prescription of fluid and feed volumes and best (0.86 [95% CI: 0.80-0.93]) for documentation of demographic characteristics. Doses of gentamicin, when prescribed, were at least 20% higher than recommended in 11.7% cases. Larger (often public) facilities tended to have higher process and structural quality scores compared with smaller, predominantly private, facilities. We estimate effective coverage to be 25% (estimate range: 21-31%). These newborns received high-quality inpatient care, while almost half (44.5%) of newborns needed care but did not receive it and a further 30.4% of newborns received an inadequate service. Failure to receive services and gaps in quality of care both contribute to a shortfall in effective coverage in Nairobi City County. Three-quarters of small and sick newborns do not have access to high-quality facility-based care. Substantial improvements in effective coverage will be required to tackle high neonatal mortality in this urban setting with high levels of poverty.

  2. A method for deriving a 4D-interpolated balanced planning target for mobile tumor radiotherapy.

    PubMed

    Roland, Teboh; Hales, Russell; McNutt, Todd; Wong, John; Simari, Patricio; Tryggestad, Erik

    2012-01-01

    Tumor control and normal tissue toxicity are strongly correlated to the tumor and normal tissue volumes receiving high prescribed dose levels in the course of radiotherapy. Planning target definition is, therefore, crucial to ensure favorable clinical outcomes. This is especially important for stereotactic body radiation therapy of lung cancers, characterized by high fractional doses and steep dose gradients. The shift in recent years from population-based to patient-specific treatment margins, as facilitated by the emergence of 4D medical imaging capabilities, is a major improvement. The commonly used motion-encompassing, or internal-target volume (ITV), target definition approach provides a high likelihood of coverage for the mobile tumor but inevitably exposes healthy tissue to high prescribed dose levels. The goal of this work was to generate an interpolated balanced planning target that takes into account both tumor coverage and normal tissue sparing from high prescribed dose levels, thereby improving on the ITV approach. For each 4DCT dataset, 4D deformable image registration was used to derive two bounding targets, namely, a 4D-intersection and a 4D-composite target which minimized normal tissue exposure to high prescribed dose levels and maximized tumor coverage, respectively. Through definition of an "effective overlap volume histogram" the authors derived an "interpolated balanced planning target" intended to balance normal tissue sparing from prescribed doses with tumor coverage. To demonstrate the dosimetric efficacy of the interpolated balanced planning target, the authors performed 4D treatment planning based on deformable image registration of 4D-CT data for five previously treated lung cancer patients. Two 4D plans were generated per patient, one based on the interpolated balanced planning target and the other based on the conventional ITV target. Plans were compared for tumor coverage and the degree of normal tissue sparing resulting from the new approach was quantified. Analysis of the 4D dose distributions from all five patients showed that while achieving tumor coverage comparable to the ITV approach, the new planning target definition resulted in reductions of lung V(10), V(20), and V(30) of 6.3% ± 1.7%, 10.6% ± 3.9%, and 12.9% ± 5.5%, respectively, as well as reductions in mean lung dose, mean dose to the GTV-ring and mean heart dose of 8.8% ± 2.5%, 7.2% ± 2.5%, and 10.6% ± 3.6%, respectively. The authors have developed a simple and systematic approach to generate a 4D-interpolated balanced planning target volume that implicitly incorporates the dynamics of respiratory-organ motion without requiring 4D-dose computation or optimization. Preliminary results based on 4D-CT data of five previously treated lung patients showed that this new planning target approach may improve normal tissue sparing without sacrificing tumor coverage.

  3. Targeting MRS-Defined Dominant Intraprostatic Lesions with Inverse-Planned High Dose Rate Brachytherapy

    DTIC Science & Technology

    2007-02-01

    bladder and the rectum are overprotected while the PTV coverage is undesirably reduced. On the other hand, if their maximum dose is increased and/or...B, the bladder and rectum were overprotected with undesirably low PTV coverage (84.54%). The reduction of their weighting factor increased PTV

  4. What Do All These Numbers Mean? Data Visualization as an Innovative Methodology to Make Program Decisions

    ERIC Educational Resources Information Center

    Porter, Susan G.; Koch, Steven P.; Henderson, Andrew

    2010-01-01

    Background: There is a lack of consistent, comprehensible data collection and analysis methods for evaluating teacher preparation program's coverage of required standards for accreditation. Of particular concern is the adequate coverage of standards and competencies that address the teaching of English learners and teachers of students from…

  5. News Agency Coverage of the United States Withdrawal from UNESCO.

    ERIC Educational Resources Information Center

    Giffard, C. Anthony

    A study was conducted to examine news coverage of the U.S. withdrawal from Unesco. News reports distributed by the Associated Press, United Press International, New York Times News Service, and Washington Post-Los Angeles Times News Service were studied to determine how adequate a foundation they were providing Americans for independent judgment…

  6. A Dosimetric Comparison of Breast Radiotherapy Techniques to Treat Locoregional Lymph Nodes Including the Internal Mammary Chain.

    PubMed

    Ranger, A; Dunlop, A; Hutchinson, K; Convery, H; Maclennan, M K; Chantler, H; Twyman, N; Rose, C; McQuaid, D; Amos, R A; Griffin, C; deSouza, N M; Donovan, E; Harris, E; Coles, C E; Kirby, A

    2018-06-01

    Radiotherapy target volumes in early breast cancer treatment increasingly include the internal mammary chain (IMC). In order to maximise survival benefits of IMC radiotherapy, doses to the heart and lung should be minimised. This dosimetry study compared the ability of three-dimensional conformal radiotherapy, arc therapy and proton beam therapy (PBT) techniques with and without breath-hold to achieve target volume constraints while minimising dose to organs at risk (OARs). In 14 patients' datasets, seven IMC radiotherapy techniques were compared: wide tangent (WT) three-dimensional conformal radiotherapy, volumetric-modulated arc therapy (VMAT) and PBT, each in voluntary deep inspiratory breath-hold (vDIBH) and free breathing (FB), and tomotherapy in FB only. Target volume coverage and OAR doses were measured for each technique. These were compared using a one-way ANOVA with all pairwise comparisons tested using Bonferroni's multiple comparisons test, with adjusted P-values ≤ 0.05 indicating statistical significance. One hundred per cent of WT(vDIBH), 43% of WT(FB), 100% of VMAT(vDIBH), 86% of VMAT(FB), 100% of tomotherapy FB and 100% of PBT plans in vDIBH and FB passed all mandatory constraints. However, coverage of the IMC with 90% of the prescribed dose was significantly better than all other techniques using VMAT(vDIBH), PBT(vDIBH) and PBT(FB) (mean IMC coverage ± 1 standard deviation = 96.0% ± 4.3, 99.8% ± 0.3 and 99.0% ± 0.2, respectively). The mean heart dose was significantly reduced in vDIBH compared with FB for both the WT (P < 0.0001) and VMAT (P < 0.0001) techniques. There was no advantage in target volume coverage or OAR doses for PBT(vDIBH) compared with PBT(FB). Simple WT radiotherapy delivered in vDIBH achieves satisfactory coverage of the IMC while meeting heart and lung dose constraints. However, where higher isodose coverage is required, VMAT(vDIBH) is the optimal photon technique. The lowest OAR doses are achieved by PBT, in which the use of vDIBH does not improve dose statistics. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  7. Reduction of the estimated radiation dose and associated patient risk with prospective ECG-gated 256-slice CT coronary angiography

    NASA Astrophysics Data System (ADS)

    Efstathopoulos, E. P.; Kelekis, N. L.; Pantos, I.; Brountzos, E.; Argentos, S.; Grebáč, J.; Ziaka, D.; Katritsis, D. G.; Seimenis, I.

    2009-09-01

    Computed tomography (CT) coronary angiography has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but high radiation doses have been reported. Prospective ECG-gating using a 'step-and-shoot' axial scanning protocol has been shown to reduce radiation exposure effectively while maintaining diagnostic accuracy. 256-slice scanners with 80 mm detector coverage have been currently introduced into practice, but their impact on radiation exposure has not been adequately studied. The aim of this study was to assess radiation doses associated with CT coronary angiography using a 256-slice CT scanner. Radiation doses were estimated for 25 patients scanned with either prospective or retrospective ECG-gating. Image quality was assessed objectively in terms of mean CT attenuation at selected regions of interest on axial coronary images and subjectively by coronary segment quality scoring. It was found that radiation doses associated with prospective ECG-gating were significantly lower than retrospective ECG-gating (3.2 ± 0.6 mSv versus 13.4 ± 2.7 mSv). Consequently, the radiogenic fatal cancer risk for the patient is much lower with prospective gating (0.0176% versus 0.0737%). No statistically significant differences in image quality were observed between the two scanning protocols for both objective and subjective quality assessments. Therefore, prospective ECG-gating using a 'step-and-shoot' protocol that covers the cardiac anatomy in two axial acquisitions effectively reduces radiation doses in 256-slice CT coronary angiography without compromising image quality.

  8. Measuring Adolescent Human Papillomavirus Vaccine Coverage: A Match of Sexually Transmitted Disease Clinic and Immunization Registry Data.

    PubMed

    Pathela, Preeti; Jamison, Kelly; Papadouka, Vikki; Kabir, Rezaul; Markowitz, Lauri E; Dunne, Eileen F; Schillinger, Julia A

    2016-12-01

    Human papillomavirus (HPV) vaccine is recommended for adolescents. By the end of 2013, 64% of female and 40% of male New York City residents aged 13-18 years had received ≥1 HPV vaccine dose. Adolescents attending sexually transmitted disease (STD) clinics are at high risk for HPV exposure and could benefit from vaccination. Our objective was to estimate HPV vaccination coverage for this population. We matched records of New York City's STD clinic patients aged 13-18 years during 2010-2013 with the Citywide Immunization Registry. We assessed HPV vaccine initiation (≥1 dose) and series completion (≥3 doses among those who initiated) as of clinic visit date and by patient demographics. We compared receipt of ≥1 dose for HPV, tetanus-diphtheria-acellular pertussis, and meningococcal conjugate vaccine. Eighty-two percent of clinic attendees (13,505/16,364) had records in the Citywide Immunization Registry. Receipt of ≥1 HPV dose increased during 2010-2013 (females: 57.6%-69.7%; males: 1.5%-36.3%). Among females, ≥1-dose coverage was lowest among whites (53.4%) and highest among Hispanics (73.3%); among males, ≥1-dose coverage was lowest among whites (6.9%) and highest among Asians (20.9%). Series completion averaged 57.7% (females) and 28.0% (males), with little variation by race/ethnicity or poverty level. Receipt of ≥1 dose was 59.7% for HPV, 82% for tetanus-diphtheria-acellular pertussis, and 76% for meningococcal conjugate vaccines. HPV vaccine initiation and completion were low among adolescent STD clinic patients; coverage was lower compared with other recommended vaccines. STD clinics may be good venues for delivering HPV vaccine, thereby enhancing efforts to improve HPV vaccination. Copyright © 2016 Society for Adolescent Health and Medicine. All rights reserved.

  9. SU-E-T-09: A Clinical Implementation and Optimized Dosimetry Study of Freiberg Flap Skin Surface Treatment in High Dose Rate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Syh, J; Syh, J; Patel, B

    Purpose: This case study was designated to confirm the optimized plan was used to treat skin surface of left leg in three stages. 1. To evaluate dose distribution and plan quality by alternating of the source loading catheters pattern in flexible Freiberg Flap skin surface (FFSS) applicator. 2. To investigate any impact on Dose Volume Histogram (DVH) of large superficial surface target volume coverage. 3. To compare the dose distribution if it was treated with electron beam. Methods: The Freiburg Flap is a flexible mesh style surface mold for skin radiation or intraoperative surface treatments. The Freiburg Flap consists ofmore » multiple spheres that are attached to each other, holding and guiding up to 18 treatment catheters. The Freiburg Flap also ensures a constant distance of 5mm from the treatment catheter to the surface. Three treatment trials with individual planning optimization were employed: 18 channels, 9 channels of FF and 6 MeV electron beam. The comparisons were highlighted in target coverage, dose conformity and dose sparing of surrounding tissues. Results: The first 18 channels brachytherapy plan was generated with 18 catheters inside the skin-wrapped up flap (Figure 1A). A second 9 catheters plan was generated associated with the same calculation points which were assigned to match prescription for target coverage as 18 catheters plan (Figure 1B). The optimized inverse plan was employed to reduce the dose to adjacent structures such as tibia or fibula. The comparison of DVH’s was depicted on Figure 2. External beam of electron RT plan was depicted in Figure 3. Overcall comparisons among these three were illustrated in Conclusion: The 9-channel Freiburg flap flexible skin applicator offers a reasonably acceptable plan without compromising the coverage. Electron beam was discouraged to use to treat curved skin surface because of low target coverage and high dose in adjacent tissues.« less

  10. Dosimetric differences between intraoperative and postoperative plans using Cs-131 in transrectal ultrasound–guided brachytherapy for prostatic carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, Andrew, E-mail: aojones@geisinger.edu; Treas, Jared; Yavoich, Brian

    2014-01-01

    The aim of the study was to investigate the differences between intraoperative and postoperative dosimetry for transrectal ultrasound–guided transperineal prostate implants using cesium-131 ({sup 131}Cs). Between 2006 and 2010, 166 patients implanted with {sup 131}Cs had both intraoperative and postoperative dosimetry studies. All cases were monotherapy and doses of 115 were prescribed to the prostate. The dosimetric properties (D{sub 90}, V{sub 150}, and V{sub 100} for the prostate) of the studies were compared. Two conformity indices were also calculated and compared. Finally, the prostate was automatically sectioned into 6 sectors (anterior and posterior sectors at the base, midgland, and apex)more » and the intraoperative and postoperative dosimetry was compared in each individual sector. Postoperative dosimetry showed statistically significant changes (p < 0.01) in every dosimetric value except V{sub 150}. In each significant case, the postoperative plans showed lower dose coverage. The conformity indexes also showed a bimodal frequency distribution with the index indicating poorer dose conformity in the postoperative plans. Sector analysis revealed less dose coverage postoperatively in the base and apex sectors with an increase in dose to the posterior midgland sector. Postoperative dosimetry overall and in specific sectors of the prostate differs significantly from intraoperative planning. Care must be taken during the intraoperative planning stage to ensure complete dose coverage of the prostate with the understanding that the final postoperative dosimetry will show less dose coverage.« less

  11. Hepatitis B vaccination coverage among adults aged ≥18 years traveling to a country of high or intermediate endemicity, United States, 2015.

    PubMed

    Lu, Peng-Jun; O'Halloran, Alissa C; Williams, Walter W; Nelson, Noele P

    2018-04-28

    Persons from the United States who travel to developing countries are at substantial risk for hepatitis B virus (HBV) infection. Hepatitis B vaccine has been recommended for adults at increased risk for infection, including travelers to high or intermediate hepatitis B endemic countries. To assess hepatitis B vaccination coverage among adults ≥18 years traveling to a country of high or intermediate endemicity from the United States. Data from the 2015 National Health Interview Survey (NHIS) were analyzed to determine hepatitis B vaccination coverage (≥1 dose) and series completion (≥3 doses) among persons aged ≥18 years who reported traveling to a country of high or intermediate hepatitis B endemicity. Multivariable logistic regression and predictive marginal analyses were conducted to identify factors independently associated with hepatitis B vaccination. In 2015, hepatitis B vaccination coverage (≥1 dose) among adults aged ≥18 years who reported traveling to high or intermediate hepatitis B endemic countries was 38.6%, significantly higher compared with 25.9% among non-travelers. Series completion (≥3 doses) was 31.7% and 21.2%, respectively (P < 0.05). On multivariable analysis among all respondents, travel status was significantly associated with hepatitis B vaccination coverage and series completion. Other characteristics independently associated with vaccination (≥1 dose, and ≥3 doses) among travelers included age, race/ethnicity, educational level, duration of US residence, number of physician contacts in the past year, status of ever being tested for HIV, and healthcare personnel status. Although travel to a country of high or intermediate hepatitis B endemicity was associated with higher likelihood of hepatitis B vaccination, hepatitis B vaccination coverage was low among adult travelers to these areas. Healthcare providers should ask their patients about travel plans and recommend and offer travel related vaccinations to their patients or refer them to alternate sites for vaccination. Published by Elsevier Ltd.

  12. Hepatitis B vaccination coverage among adults aged ≥ 18 years traveling to a country of high or intermediate endemicity, United States, 2015.

    PubMed

    Lu, Peng-Jun; O'Halloran, Alissa C; Williams, Walter W; Nelson, Noele P

    2018-04-25

    Persons from the United States who travel to developing countries are at substantial risk for hepatitis B virus (HBV) infection. Hepatitis B vaccine has been recommended for adults at increased risk for infection, including travelers to high or intermediate hepatitis B endemic countries. To assess hepatitis B vaccination coverage among adults ≥ 18 years traveling to a country of high or intermediate endemicity from the United States. Data from the 2015 National Health Interview Survey (NHIS) were analyzed to determine hepatitis B vaccination coverage (≥1 dose) and series completion (≥3 doses) among persons aged ≥ 18 years who reported traveling to a country of high or intermediate hepatitis B endemicity. Multivariable logistic regression and predictive marginal analyses were conducted to identify factors independently associated with hepatitis B vaccination. In 2015, hepatitis B vaccination coverage (≥1 dose) among adults aged ≥ 18 years who reported traveling to high or intermediate hepatitis B endemic countries was 38.6%, significantly higher compared with 25.9% among non-travelers. Series completion (≥3 doses) was 31.7% and 21.2%, respectively (P < 0.05). On multivariable analysis among all respondents, travel status was significantly associated with hepatitis B vaccination coverage and series completion. Other characteristics independently associated with vaccination (≥1 dose, and ≥ 3 doses) among travelers included age, race/ethnicity, educational level, duration of U.S. residence, number of physician contacts in the past year, status of ever being tested for HIV, and healthcare personnel status. Although travel to a country of high or intermediate hepatitis B endemicity was associated with higher likelihood of hepatitis B vaccination, hepatitis B vaccination coverage was low among adult travelers to these areas. Healthcare providers should ask their patients about travel plans and recommend and offer travel related vaccinations to their patients or refer them to alternate sites for vaccination. Published by Elsevier Ltd.

  13. Racial/ethnic differences in health insurance adequacy and consistency among children: Evidence from the 2011/12 National Survey of Children’s Health

    PubMed Central

    Soylu, Tulay G.; Elashkar, Eman; Aloudah, Fatemah; Ahmed, Munir; Kitsantas, Panagiota

    2018-01-01

    Background Surveillance of disparities in healthcare insurance, services and quality of care among children are critical for properly serving the medical/healthcare needs of underserved populations. The purpose of this study was to assess racial/ethnic differences in children’s (0 to 17 years old) health insurance adequacy and consistency (child has insurance coverage for the last 12 months). Design and methods We used data from the 2011/2012 National Survey of Children’s Health (n=79,474). Descriptive statistics and logistic regression analyses were conducted to examine the distribution and influence of several sociodemographic/family related factors on insurance adequacy and consistency across different racial/ethnic groups. Results Stratified analyses by race/ethnicity revealed that white and black children living in households at or below 299% of the Federal Poverty Level (FPL) were approximately 29 to 42% less likely to have adequate insurance compared to children living in families of higher income levels. Regardless of race/ethnicity, we found that children with public health insurance were more likely to have adequate insurance than their privately insured counterparts, while adolescents were at greater risk of inadequate coverage. Hispanic and black children were more likely to lack consistent insurance coverage. Conclusions This study provides evidence that racial/ethnic differences in adequate and consistent health insurance exists with both white and minority children being affected adversely by poverty. Establishing outreach programs for low income families, and cross-cultural education for healthcare providers may help increase health insurance adequacy and consistency within certain underserved populations. Significance for public healthAs the number of minority US children increases, monitoring racial/ethnic differences in health insurance coverage becomes critical in creating insurance programs that can provide adequate and consistent coverage. Using a nationally representative sample, the findings of this study suggest that low income and poor maternal health can adversely affect insurance consistency and adequacy for both minority and white children. This indicates that research studies on inequalities of healthcare coverage should also focus on underserved white populations of children as their insurance coverage is affected by similar factors as those for minority children. Elimination of inequalities may require targeted interventions that include the well-being of the entire family, cross-cultural education of healthcare providers, policy changes to grant low-income children with appropriate and reliable health insurance, and an ongoing monitoring of disparities by health plans. PMID:29780766

  14. The role of helical tomotherapy in the treatment of bone plasmacytoma.

    PubMed

    Chargari, Cyrus; Hijal, Tarek; Bouscary, Didier; Caussa, Lucas; Dendale, Remi; Zefkili, Sofia; Fourquet, Alain; Kirova, Youlia M

    2012-01-01

    We evaluated the early clinical outcome of patients with solitary bone plasmacytoma (SP) or a solitary lesion of multiple myeloma (MM) treated with helical tomotherapy (HT) compared with 3D conformal radiotherapy (3D-CRT), in terms of target coverage and exposure of critical organs. Ten patients with SP and 3 patients with a solitary lesion of MM underwent radiation therapy (RT) delivered by HT, to a dose of 40 Gy in 20 fractions. Treatment planning was then performed with 3D-CRT and the dosimetric parameters of both techniques were compared. Patients were also assessed for response to treatment and acute toxicities. With a median follow-up of 13 months, 78% of patients with pain before RT had resolution of their symptoms. Coverage of target lesion was adequate with both techniques in 12 of 13 patients. Target coverage was significantly lower for HT (V(95%) = 98.55% vs. 97.15%; p = 0.04, for 3D-CRT and HT, respectively). Target overdoses were also lower with HT (V(105%) = 2.01% vs. 0.19%; p= 0.16), although nonsignificant. Finally, there were no significant differences in organs-at-risk irradiation between both techniques. The early treatment tolerance was excellent, with no toxicity higher than grade I. RT of SP and MM with a solitary lesion can be safely delivered with HT, with no major acute side effects and good symptomatic control. Finally, HT provides a dosimetry similar to that of 3D-CRT in terms of organs-at-risk sparing and target volume coverage. Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  15. The challenges of sustainable access to safe drinking water in rural areas of developing countries: case of Zawtar El-Charkieh, Southern Lebanon.

    PubMed

    Massoud, May A; Al-Abady, Abdolmonim; Jurdi, Mey; Nuwayhid, Iman

    2010-06-01

    Adequate and safe water is important for human health and well-being, economic production, and sustainable development. Failure to ensure the safety of drinking water may expose the community to the risk of outbreaks of waterborne and infectious diseases. Although drinking water is a basic human right, many people do not have access to safe and adequate drinking water or proper sanitation facilities. The authors conducted a study to assess the quantity, cost, continuity, coverage, and quality of drinking water in the village of Zawtar El-Charkieh, Lebanon. Their aim was to identify the challenges of sustainable access to safe drinking water in order to determine the short-term management actions and long-term strategies to improve water quality. Results revealed that contamination of the source, absence of any disinfection method or insufficient dose, poor maintenance operations, and aging of the networks are significant factors contributing to water contamination during the storage and distribution process. Establishing a comprehensive drinking water system that integrates water supply, quality, and management as well as associated educational programs in order to ensure the safety and sustainability of drinking water supplies is essential.

  16. Quantification of interplay and gradient effects for lung stereotactic ablative radiotherapy (SABR) treatments.

    PubMed

    Tyler, Madelaine K

    2016-01-08

    This study quantified the interplay and gradient effects on GTV dose coverage for 3D CRT, dMLC IMRT, and VMAT SABR treatments for target amplitudes of 5-30 mm using 3DVH v3.1 software incorporating 4D Respiratory MotionSim (4D RMS) module. For clinically relevant motion periods (5 s), the interplay effect was small, with deviations in the minimum dose covering the target volume (D99%) of less than ± 2.5% for target amplitudes up to 30 mm. Increasing the period to 60 s resulted in interplay effects of up to ± 15.0% on target D99% dose coverage. The gradient effect introduced by target motion resulted in deviations of up to ± 3.5% in D99% target dose coverage. VMAT treatments showed the largest deviation in dose metrics, which was attributed to the long delivery times in comparison to dMLC IMRT. Retrospective patient analysis indicated minimal interplay and gradient effects for patients treated with dMLC IMRT at the NCCI.

  17. Complete immunization coverage and its determinants among children in Malaysia: findings from the National Health and Morbidity Survey (NHMS) 2016.

    PubMed

    Lim, K K; Chan, Y Y; Noor Ani, A; Rohani, J; Siti Norfadhilah, Z A; Santhi, M R

    2017-12-01

    The success of the Expanded Program on Immunization among children will greatly reduce the burden of illness and disability from vaccine preventable diseases. The aim of the study was to evaluate the complete immunization coverage and its determinants among children aged 12-23 months in Malaysia. Cross-sectional study. Data on immunization were extracted from the 2016 National Health and Morbidity Survey. Complete immunization coverage was classified as received all recommended primary vaccine doses by the age of 12 months and verified by vaccination cards, and incompletely immunized if they received partially recommended vaccine dose or not received any recommended vaccine dose or had no vaccination card. The multiple logistic regression analyses were conducted to determine the sociodemographic factors associated with complete immunization coverage. The overall complete immunization coverage among children (verified by cards) was 86.4% (n = 8920, 95% confidence interval: 85.4-87.4). Multivariable logistic regression analyses model revealed that factors significantly associated with complete immunization coverage were ethnicity, occupation of the mother, head of household's education level, and head of household's occupation. While sex, citizenship, household income, mother's age, and marital status were not significantly associated with complete immunization coverage. According to the World Health Organization criteria, the present study demonstrated that the immunization coverage of 86.4% is still unsatisfactory. Thus, the current intervention program should be enhanced in order to achieve the 95% coverage for all antigens in the national vaccination program. Copyright © 2017 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  18. [Medical coverage of a road bicycle race].

    PubMed

    Reifferscheid, Florian; Stuhr, Markus; Harding, Ulf; Schüler, Christine; Thoms, Jürgen; Püschel, Klaus; Kappus, Stefan

    2010-07-01

    Major sport events require adequate expertise and experience concerning medical coverage and support. Medical and ambulance services need to cover both participants and spectators. Likewise, residents at the venue need to be provided for. Concepts have to include the possibility of major incidents related to the event. Using the example of the Hamburg Cyclassics, a road bicycle race and major event for professional and amateur cyclists, this article describes the medical coverage, number of patients, types of injuries and emergencies. Objectives regarding the planning of future events and essential medical coverage are consequently discussed. (c) Georg Thieme Verlag Stuttgart-New York.

  19. Carbon-ion scanning lung treatment planning with respiratory-gated phase-controlled rescanning: simulation study using 4-dimensional CT data.

    PubMed

    Takahashi, Wataru; Mori, Shinichiro; Nakajima, Mio; Yamamoto, Naoyoshi; Inaniwa, Taku; Furukawa, Takuji; Shirai, Toshiyuki; Noda, Koji; Nakagawa, Keiichi; Kamada, Tadashi

    2014-11-11

    To moving lung tumors, we applied a respiratory-gated strategy to carbon-ion pencil beam scanning with multiple phase-controlled rescanning (PCR). In this simulation study, we quantitatively evaluated dose distributions based on 4-dimensional CT (4DCT) treatment planning. Volumetric 4DCTs were acquired for 14 patients with lung tumors. Gross tumor volume, clinical target volume (CTV) and organs at risk (OARs) were delineated. Field-specific target volumes (FTVs) were calculated, and 48Gy(RBE) in a single fraction was prescribed to the FTVs delivered from four beam angles. The dose assessment metrics were quantified by changing the number of PCR and the results for the ungated and gated scenarios were then compared. For the ungated strategy, the mean dose delivered to 95% of the volume of the CTV (CTV-D95) was in average 45.3 ± 0.9 Gy(RBE) even with a single rescanning (1 × PCR). Using 4 × PCR or more achieved adequate target coverage (CTV-D95 = 46.6 ± 0.3 Gy(RBE) for ungated 4 × PCR) and excellent dose homogeneity (homogeneity index =1.0 ± 0.2% for ungated 4 × PCR). Applying respiratory gating, percentage of lung receiving at least 20 Gy(RBE) (lung-V20) and heart maximal dose, averaged over all patients, significantly decreased by 12% (p < 0.05) and 13% (p < 0.05), respectively. Four or more PCR during PBS-CIRT improved dose conformation to moving lung tumors without gating. The use of a respiratory-gated strategy in combination with PCR reduced excessive doses to OARs.

  20. CFD simulation of pesticide spray from air-assisted sprayers in an apple orchard: tree deposition and off-target losses

    USDA-ARS?s Scientific Manuscript database

    The ultimate goal of a pesticide spraying system is to provide adequate coverage on intended canopies with a minimum amount of spray materials and off-target waste. Better spray coverage requires an understanding of the fate and transport of spray droplets carried by turbulent airflows in orchards. ...

  1. Systematic review of the incremental costs of interventions that increase immunization coverage.

    PubMed

    Ozawa, Sachiko; Yemeke, Tatenda T; Thompson, Kimberly M

    2018-05-10

    Achieving and maintaining high vaccination coverage requires investments, but the costs and effectiveness of interventions to increase coverage remain poorly characterized. We conducted a systematic review of the literature to identify peer-reviewed studies published in English that reported interventions aimed at increasing immunization coverage and the associated costs and effectiveness of the interventions. We found limited information in the literature, with many studies reporting effectiveness estimates, but not providing cost information. Using the available data, we developed a cost function to support future programmatic decisions about investments in interventions to increase immunization coverage for relatively low and high-income countries. The cost function estimates the non-vaccine cost per dose of interventions to increase absolute immunization coverage by one percent, through either campaigns or routine immunization. The cost per dose per percent increase in absolute coverage increased with higher baseline coverage, demonstrating increasing incremental costs required to reach higher coverage levels. Future studies should evaluate the performance of the cost function and add to the database of available evidence to better characterize heterogeneity in costs and generalizability of the cost function. Copyright © 2018. Published by Elsevier Ltd.

  2. Determinants of apparent rural-urban differentials in measles vaccination uptake in Indonesia.

    PubMed

    Fernandez, Renae C; Awofeso, Niyi; Rammohan, Anu

    2011-01-01

    Regional differences in vaccination uptake are common in both developed and developing countries, and are often linked to the availability of healthcare services and socioeconomic factors. In 2007, 0.9 million eligible Indonesian children missed measles vaccination, and 19 456 cases of measles were documented among Indonesian children. The authors investigated rural-urban differentials in measles vaccination coverage among young Indonesian children, and sought to identify key factors influencing the probability of a child receiving the first dose of measles vaccination in Indonesia. Data used in the analyses were sourced from the nationally representative Indonesia Demographic and Health Survey 2007. The influence of location of residence, household wealth, maternal and paternal education, total children ever born and use of skilled birth attendants on measles vaccination coverage was investigated using bivariate analysis and chi-square tests. The independent effects of these variables were established using binomial logistic regression analysis. Indonesia's 2007 first-dose measles national vaccination coverage was, at 72.8%, lower than the 2008 global first-dose measles vaccination average coverage of 82%. Bivariate analysis revealed that the first-dose measles vaccination coverage in rural areas of Indonesia was 68.5%, compared with 80.1% in urban regions (p < 0.001). The apparent significance of rural residence in impairing vaccination coverage was marginal after controlling for the sex of the child, maternal age, maternal and paternal education, wealth, and access to skilled health workers. Apart from sustainable initiatives to increase measles vaccination coverage globally, it is important to close the rural-urban gap in Indonesia's measles vaccination uptake. Addressing critical determinants of inferior measles vaccination coverage in Indonesia's rural regions will facilitate major improvements in Indonesia's child health trends. This article suggests initiatives for addressing three of such determinants in Indonesia's rural areas: poverty, parental education and access to skilled health workers.

  3. SU-F-19A-12: Split-Ring Applicator with Interstitial Needle for Improved Volumetric Coverage in HDR Brachytherapy for Cervical Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sherertz, T; Ellis, R; Colussi, V

    2014-06-15

    Purpose: To evaluate volumetric coverage of a Mick Radionuclear titanium Split-Ring applicator (SRA) with/without interstitial needle compared to an intracavitary Vienna applicator (VA), interstitial-intracavitary VA, and intracavitary ring and tandem applicator (RTA). Methods: A 57 year-old female with FIGO stage IIB cervical carcinoma was treated following chemoradiotherapy (45Gy pelvic and 5.4Gy parametrial boost) with highdose- rate (HDR) brachytherapy to 30Gy in 5 fractions using a SRA. A single interstitial needle was placed using the Ellis Interstitial Cap for the final three fractions to increase coverage of left-sided gross residual disease identified on 3T-MRI. High-risk (HR) clinical target volume (CTV) andmore » intermediate-risk (IR) CTV were defined using axial T2-weighted 2D and 3D MRI sequences (Philips PET/MRI unit). Organs-at-risks (OARs) were delineated on CT. Oncentra planning system was used for treatment optimization satisfying GEC-ESTRO guidelines for target coverage and OAR constraints. Retrospectively, treatment plans (additional 20 plans) were simulated using intracavitary SRA (without needle), intracavitary VA (without needle), interstitial-intracavitary VA, and intracavitary RTA with this same patient case. Plans were optimized for each fraction to maintain coverage to HR-CTV. Results: Interstitial-intracavitary SRA achieved the following combined coverage for external radiation and brachytherapy (EQD2): D90 HR-CTV =94.6Gy; Bladder-2cc =88.9Gy; Rectum-2cc =65.1Gy; Sigmoid-2cc =48.9Gy; Left vaginal wall (VW) =103Gy, Right VW =99.2Gy. Interstitial-intracavitary VA was able to achieve identical D90 HR-CTV =94.6Gy, yet Bladder-2cc =91.9Gy (exceeding GEC-ESTRO recommendations of 2cc<90Gy) and Left VW =120.8Gy and Right VW =115.5Gy. Neither the SRA nor VA without interstitial needle could cover HR-CTV adequately without exceeding dose to Bladder-2cc. Conventional RTA was unable to achieve target coverage for the HR-CTV >80Gy without severely overdosing OARs. Conclusion: The Ellis Interstitial Cap for the SRA offered superior dosimetric coverage as compared to the interstitialintracavitary VA. This represents the first reported use for this devise, and further investigation is warranted.« less

  4. A motion phantom study on helical tomotherapy: the dosimetric impacts of delivery technique and motion

    NASA Astrophysics Data System (ADS)

    Kanagaki, Brian; Read, Paul W.; Molloy, Janelle A.; Larner, James M.; Sheng, Ke

    2007-01-01

    Helical tomotherapy (HT) can potentially be used for lung cancer treatment including stereotactic radiosurgery because of its advanced image guidance and its ability to deliver highly conformal dose distributions. However, previous theoretical and simulation studies reported that the effect of respiratory motion on statically planned tomotherapy treatments may cause substantial differences between the calculated and actual delivered radiation isodose distribution, particularly when the treatment is hypofractionated. In order to determine the dosimetric effects of motion upon actual HT treatment delivery, phantom film dosimetry measurements were performed under static and moving conditions using a clinical HT treatment unit. The motion phantom system was constructed using a programmable motor, a base, a moving platform and a life size lung heterogeneity phantom with wood inserts representing lung tissue with a 3.0 cm diameter spherical tumour density equivalent insert. In order to determine the effects of different motion and tomotherapy delivery parameters, treatment plans were created using jaw sizes of 1.04 cm and 2.47 cm, with incremental gantry rotation periods between the minimum allowed (10 s) and the maximum allowed (60 s). The couch speed varied from 0.009 cm s-1 to 0.049 cm s-1, and delivered to a phantom under static and dynamic conditions with peak-to-peak motion amplitudes of 1.2 cm and 2 cm and periods of 3 and 5 s to simulate human respiratory motion of lung tumours. A cylindrical clinical target volume (CTV) was contoured to tightly enclose the tumour insert. 2.0 Gy was prescribed to 95% of the CTV. Two-dimensional dose was measured by a Kodak EDR2 film. Dynamic phantom doses were then quantitatively compared to static phantom doses in terms of axial dose profiles, cumulative dose volume histograms (DVH), percentage of CTV receiving the prescription dose and the minimum dose received by 95% of the CTV. The larger motion amplitude resulted in more under-dosing at the ends of the CTV in the axis of motion, and this effect was greater for the smaller jaw size plans. Due to the size of the penumbra, the 2.47 cm jaw plans provide adequate coverage for smaller amplitudes of motion, ±0.6 cm in our experiment, without adding any additional margin in the axis of motion to the treatment volume. The periodic heterogeneous patterns described by previous studies were not observed from the single fraction of the phantom measurement. Besides the jaw sizes, CTV dose coverage is not significantly dependent on machine and phantom motion periods. The lack of adverse synchronization patterns from both results validate that HT is a safe technique for treating moving target and hypofractionation.

  5. SU-F-J-57: Effectiveness of Daily CT-Based Three-Dimensional Image Guided and Adaptive Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moriya, S; National Cancer Center, Kashiwa, Chiba; Tachibana, H

    Purpose: Daily CT-based three-dimensional image-guided and adaptive (CTIGRT-ART) proton therapy system was designed and developed. We also evaluated the effectiveness of the CTIGRT-ART. Methods: Retrospective analysis was performed in three lung cancer patients: Proton treatment planning was performed using CT image datasets acquired by Toshiba Aquilion ONE. Planning target volume and surrounding organs were contoured by a well-trained radiation oncologist. Dose distribution was optimized using 180-deg. and 270-deg. two fields in passive scattering proton therapy. Well commissioned Simplified Monte Carlo algorithm was used as dose calculation engine. Daily consecutive CT image datasets was acquired by an in-room CT (Toshiba Aquilionmore » LB). In our in-house program, two image registrations for bone and tumor were performed to shift the isocenter using treatment CT image dataset. Subsequently, dose recalculation was performed after the shift of the isocenter. When the dose distribution after the tumor registration exhibits change of dosimetric parameter of CTV D90% compared to the initial plan, an additional process of was performed that the range shifter thickness was optimized. Dose distribution with CTV D90% for the bone registration, the tumor registration only and adaptive plan with the tumor registration was compared to the initial plan. Results: In the bone registration, tumor dose coverage was decreased by 16% on average (Maximum: 56%). The tumor registration shows better coverage than the bone registration, however the coverage was also decreased by 9% (Maximum: 22%) The adaptive plan shows similar dose coverage of the tumor (Average: 2%, Maximum: 7%). Conclusion: There is a high possibility that only image registration for bone and tumor may reduce tumor coverage. Thus, our proposed methodology of image guidance and adaptive planning using the range adaptation after tumor registration would be effective for proton therapy. This research is partially supported by Japan Agency for Medical Research and Development (AMED).« less

  6. Dosimetric comparison of photon and proton treatment techniques for chondrosarcoma of thoracic spine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yadav, Poonam, E-mail: yadav@humonc.wisc.edu; Department of Medical Physics, University of Wisconsin, Madison, WI; University of Wisconsin Riverview Cancer Center, Wisconsin Rapids, WI

    2013-10-01

    Chondrosarcomas are relatively radiotherapy resistant, and also delivering high radiation doses is not feasible owing to anatomic constraints. In this study, the feasibility of helical tomotherapy for treatment of chondrosarcoma of thoracic spine is explored and compared with other available photon and proton radiotherapy techniques in the clinical setting. A patient was treated for high-grade chondrosarcoma of the thoracic spine using tomotherapy. Retrospectively, the tomotherapy plan was compared with intensity-modulated radiation therapy, dynamic arc photon therapy, and proton therapy. Two primary comparisons were made: (1) comparison of normal tissue sparing with comparable target volume coverage (plan-1), and (2) comparison ofmore » target volume coverage with a constrained maximum dose to the cord center (plan-2). With constrained target volume coverage, proton plans were found to yield lower mean doses for all organs at risk (spinal cord, esophagus, heart, and both lungs). Tomotherapy planning resulted in the lowest mean dose to all organs at risk amongst photon-based methods. For cord dose constrained plans, the static-field intensity-modulated radiation therapy and dynamic arc plans resulted target underdosing in 20% and 12% of planning target volume2 volumes, respectively, whereas both proton and tomotherapy plans provided clinically acceptable target volume coverage with no portion of planning target volume2 receiving less than 90% of the prescribed dose. Tomotherapy plans are comparable to proton plans and produce superior results compared with other photon modalities. This feasibility study suggests that tomotherapy is an attractive alternative to proton radiotherapy for delivering high doses to lesions in the thoracic spine.« less

  7. Under-reported dosimetry errors due to interplay effects during VMAT dose delivery in extreme hypofractionated stereotactic radiotherapy.

    PubMed

    Gauer, Tobias; Sothmann, Thilo; Blanck, Oliver; Petersen, Cordula; Werner, René

    2018-06-01

    Radiotherapy of extracranial metastases changed from normofractioned 3D CRT to extreme hypofractionated stereotactic treatment using VMAT beam techniques. Random interaction between tumour motion and dynamically changing beam parameters might result in underdosage of the CTV even for an appropriately dimensioned ITV (interplay effect). This study presents a clinical scenario of extreme hypofractionated stereotactic treatment and analyses the impact of interplay effects on CTV dose coverage. For a thoracic/abdominal phantom with an integrated high-resolution detector array placed on a 4D motion platform, dual-arc treatment plans with homogenous target coverage were created using a common VMAT technique and delivered in a single fraction. CTV underdosage through interplay effects was investigated by comparing dose measurements with and without tumour motion during plan delivery. Our study agrees with previous works that pointed out insignificant interplay effects on target coverage for very regular tumour motion patterns like simple sinusoidal motion. However, we identified and illustrated scenarios that are likely to result in a clinically relevant CTV underdosage. For tumour motion with abnormal variability, target coverage quantified by the CTV area receiving more than 98% of the prescribed dose decreased to 78% compared to 100% at static dose measurement. This study is further proof of considerable influence of interplay effects on VMAT dose delivery in stereotactic radiotherapy. For selected conditions of an exemplary scenario, interplay effects and related motion-induced target underdosage primarily occurred in tumour motion pattern with increased motion variability and VMAT plan delivery using complex MLC dose modulation.

  8. Comparing Treatment Plan in All Locations of Esophageal Cancer

    PubMed Central

    Lin, Jang-Chun; Tsai, Jo-Ting; Chang, Chih-Chieh; Jen, Yee-Min; Li, Ming-Hsien; Liu, Wei-Hsiu

    2015-01-01

    Abstract The aim of this study was to compare treatment plans of volumetric modulated arc therapy (VMAT) with intensity-modulated radiotherapy (IMRT) for all esophageal cancer (EC) tumor locations. This retrospective study from July 2009 to June 2014 included 20 patients with EC who received definitive concurrent chemoradiotherapy with radiation doses >50.4 Gy. Version 9.2 of Pinnacle3 with SmartArc was used for treatment planning. Dosimetric quality was evaluated based on doses to several organs at risk, including the spinal cord, heart, and lung, over the same coverage of gross tumor volume. In upper thoracic EC, the IMRT treatment plan had a lower lung mean dose (P = 0.0126) and lung V5 (P = 0.0037) compared with VMAT; both techniques had similar coverage of the planning target volumes (PTVs) (P = 0.3575). In middle thoracic EC, a lower lung mean dose (P = 0.0010) and V5 (P = 0.0145), but higher lung V20 (P = 0.0034), spinal cord Dmax (P = 0.0262), and heart mean dose (P = 0.0054), were observed for IMRT compared with VMAT; IMRT provided better PTV coverage. Patients with lower thoracic ECs had a lower lung mean dose (P = 0.0469) and V5 (P = 0.0039), but higher spinal cord Dmax (P = 0.0301) and heart mean dose (P = 0.0020), with IMRT compared with VMAT. PTV coverage was similar (P = 0.0858) for the 2 techniques. IMRT provided a lower mean dose and lung V5 in upper thoracic EC compared with VMAT, but exhibited different advantages and disadvantages in patients with middle or lower thoracic ECs. Thus, choosing different techniques for different EC locations is warranted. PMID:25929910

  9. Comparing treatment plan in all locations of esophageal cancer: volumetric modulated arc therapy versus intensity-modulated radiotherapy.

    PubMed

    Lin, Jang-Chun; Tsai, Jo-Ting; Chang, Chih-Chieh; Jen, Yee-Min; Li, Ming-Hsien; Liu, Wei-Hsiu

    2015-05-01

    The aim of this study was to compare treatment plans of volumetric modulated arc therapy (VMAT) with intensity-modulated radiotherapy (IMRT) for all esophageal cancer (EC) tumor locations.This retrospective study from July 2009 to June 2014 included 20 patients with EC who received definitive concurrent chemoradiotherapy with radiation doses >50.4 Gy. Version 9.2 of Pinnacle with SmartArc was used for treatment planning. Dosimetric quality was evaluated based on doses to several organs at risk, including the spinal cord, heart, and lung, over the same coverage of gross tumor volume.In upper thoracic EC, the IMRT treatment plan had a lower lung mean dose (P = 0.0126) and lung V5 (P = 0.0037) compared with VMAT; both techniques had similar coverage of the planning target volumes (PTVs) (P = 0.3575). In middle thoracic EC, a lower lung mean dose (P = 0.0010) and V5 (P = 0.0145), but higher lung V20 (P = 0.0034), spinal cord Dmax (P = 0.0262), and heart mean dose (P = 0.0054), were observed for IMRT compared with VMAT; IMRT provided better PTV coverage. Patients with lower thoracic ECs had a lower lung mean dose (P = 0.0469) and V5 (P = 0.0039), but higher spinal cord Dmax (P = 0.0301) and heart mean dose (P = 0.0020), with IMRT compared with VMAT. PTV coverage was similar (P = 0.0858) for the 2 techniques.IMRT provided a lower mean dose and lung V5 in upper thoracic EC compared with VMAT, but exhibited different advantages and disadvantages in patients with middle or lower thoracic ECs. Thus, choosing different techniques for different EC locations is warranted.

  10. SU-G-BRC-04: Collimator Angle Optimization in Volumetric Modulated Arc Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andersen, A; Johnson, C; Bartlett, G

    2016-06-15

    Purpose: Volumetric modulated arc therapy (VMAT) has revolutionized radiation treatment by decreasing treatment time and monitor units, thus reducing scattered and whole body radiation dose. As the collimator angle changes the apparent leaf gap becomes larger which can impact plan quality, organ at risk (OAR) sparing as well as IMRT QA passing rate which is investigated. Methods: Two sites (prostate and head and neck) that have maximum utilization of VMAT were investigated. Two previously treated VMAT patients were chosen. For each patient 10 plans were created by maintaining constant optimization constraints while varying collimator angles from 0-90 deg at anmore » interval of 10 degrees for the first arc and the appropriate complimentary angle for the second arc. Plans were created with AAA algorithm using 6 MV beam on a Varian IX machine with Millennium 120 MLC. The dose-volume histogram (DVH) for each plan was exported and dosimetric parameters (D98, D95, D50, D2) as well homogeneity index (HI) and conformity index (CI) were computed. Each plan was validated for QA using ArcCheck with gamma index passing criteria of 2%/2 mm and 3%/3 mm. Additionally, normal tissue complication probability (NTCP) for each OAR was computed using Uzan-Nahum software. Results: The CI values for both sites had no impact as target volume coverage in every collimator angle were the same since it was optimized for adequate coverage. The HI which is representative of DVH gradient or dose uniformity in PTV showed a clear trend in both sites. The NTCP for OAR (brain and cochlea) in H&N plan and (bladder and rectum) in prostate plan showed a distinct superiority for collimator angles between 15-30 deg. The gamma passing rates were not correlated with angle. Conclusion: Based on CI, HI, NTCP and gamma passing index, it can be concluded that collimator angles should be maintained within 15–30 deg.« less

  11. Single line source with and without vaginal loading and the impact on target coverage and organ at risk doses for cervix cancer Stages IB, II, and IIIB: treatment planning simulation in patients treated with MRI-guided adaptive brachytherapy in a multicentre study (EMBRACE).

    PubMed

    Nkiwane, Karen S; Pötter, Richard; Tanderup, Kari; Federico, Mario; Lindegaard, Jacob C; Kirisits, Christian

    2013-01-01

    Three-dimensional evaluation and comparison of target and organs at risk (OARs) doses from two traditional standard source loading patterns in the frame of MRI-guided cervical cancer brachytherapy for various clinical scenarios based on patient data collected in a multicenter trial setting. Two nonoptimized three-dimensional MRI-based treatment plans, Plan 1 (tandem and vaginal loading) and Plan 2 (tandem loading only), were generated for 134 patients from seven centers participating in the EMBRACE study. Both plans were normalized to point A (Pt. A). Target and OAR doses were evaluated in terms of minimum dose to 90% of the high-risk clinical target volume (HRCTV D90) grouped by tumor stage and minimum dose to the most exposed 2cm³ of the OARs volume. An HRCTV D90 ≥ Pt. A was achieved in 82% and 44% of the patients with Plans 1 and 2, respectively. Median HRCTV D90 with Plans 1 and 2 was 120% and 90% of Pt. A dose, respectively. Both plans had optimal dose coverage in 88% of Stage IB tumors; however, the tandem-only plan resulted in about 50% of dose reduction to the vagina and rectum. For Stages IIB and IIIB, Plan 1 had on average 35% better target coverage but with significant doses to OARs. Standard tandem loading alone results in good target coverage in most Stage IB tumors without violating OAR dose constraints. For Stage IIB tumors, standard vaginal loading improves the therapeutic window, however needs optimization to fulfill the dose prescription for target and OAR. In Stage IIIB, even optimized vaginal loading often does not fulfill the needs for dose prescription. The significant dose variation across various clinical scenarios for both target and OARs indicates the need for image-guided brachytherapy for optimal dose adaptation both for limited and advanced diseases. Copyright © 2013 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  12. Oral Cholera Vaccine Coverage during an Outbreak and Humanitarian Crisis, Iraq, 2015.

    PubMed

    Lam, Eugene; Al-Tamimi, Wasan; Russell, Steven Paul; Butt, Muhammad Obaid-Ul Islam; Blanton, Curtis; Musani, Altaf Sadrudin; Date, Kashmira

    2017-01-01

    During November-December 2015, as part of the 2015 cholera outbreak response in Iraq, the Iraqi Ministry of Health targeted ≈255,000 displaced persons >1 year of age with 2 doses of oral cholera vaccine (OCV). All persons who received vaccines were living in selected refugee camps, internally displaced persons camps, and collective centers. We conducted a multistage cluster survey to obtain OCV coverage estimates in 10 governorates that were targeted during the campaign. In total, 1,226 household and 5,007 individual interviews were conducted. Overall, 2-dose OCV coverage in the targeted camps was 87% (95% CI 85%-89%). Two-dose OCV coverage in the 3 northern governorates (91%; 95% CI 87%-94%) was higher than that in the 7 southern and central governorates (80%; 95% CI 77%-82%). The experience in Iraq demonstrates that OCV campaigns can be successfully implemented as part of a comprehensive response to cholera outbreaks among high-risk populations in conflict settings.

  13. Estimation of child vaccination coverage at state and national levels in India

    PubMed Central

    Gupta, Satish; Kumar, Rakesh; Haldar, Pradeep; Sethi, Raman; Bahl, Sunil

    2016-01-01

    Abstract Objective To review the data, for 1999–2013, on state-level child vaccination coverage in India and provide estimates of coverage at state and national levels. Methods We collated data from administrative reports, population-based surveys and other sources and used them to produce annual estimates of vaccination coverage. We investigated bacille Calmette–Guérin vaccine, the first and third doses of vaccine against diphtheria, tetanus and pertussis, the third dose of oral polio vaccine and the first dose of vaccine against measles. We obtained relevant data covering the period 1999–2013 for each of 16 states and territories and the period 2001–2013 for the state of Jharkhand – which was only created in 2000. We aggregated the resultant state-level estimates, using a population-weighted approach, to give national values. Findings For each of the vaccinations we investigated, about half of the 253 estimates of annual coverage at state level that we produced were based on survey results. The rest were based on interpolation between – or extrapolation from – so-called anchor points or, more rarely, on administrative data. Our national estimates indicated that, for each of the vaccines we investigated, coverage gradually increased between 1999 and 2010 but then levelled off. Conclusion The delivery of routine vaccination services to Indian children appears to have improved between 1999 and 2013. There remains considerable scope to improve the recording and reporting of childhood vaccination coverage in India and regular systematic reviews of the coverage data are recommended. PMID:27843162

  14. 44 CFR 206.101 - Temporary housing assistance for emergencies and major disasters declared on or before October 14...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... adequate rent-free housing accommodations; or (v) To an applicant who has adequate insurance coverage and.... The exceptions to this are when existing rental resources are not available and repairs to the home... or pending provision of other temporary housing resources. Transient accommodations may be provided...

  15. 44 CFR 206.101 - Temporary housing assistance for emergencies and major disasters declared on or before October 14...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... adequate rent-free housing accommodations; or (v) To an applicant who has adequate insurance coverage and.... The exceptions to this are when existing rental resources are not available and repairs to the home... or pending provision of other temporary housing resources. Transient accommodations may be provided...

  16. 44 CFR 206.101 - Temporary housing assistance for emergencies and major disasters declared on or before October 14...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... adequate rent-free housing accommodations; or (v) To an applicant who has adequate insurance coverage and.... The exceptions to this are when existing rental resources are not available and repairs to the home... or pending provision of other temporary housing resources. Transient accommodations may be provided...

  17. Oral Cholera Vaccine Coverage, Barriers to Vaccination, and Adverse Events following Vaccination, Haiti, 2013.

    PubMed

    Tohme, Rania A; François, Jeannot; Wannemuehler, Kathleen; Iyengar, Preetha; Dismer, Amber; Adrien, Paul; Hyde, Terri B; Marston, Barbara J; Date, Kashmira; Mintz, Eric; Katz, Mark A

    2015-06-01

    In 2013, the first government-led oral cholera vaccination (OCV) campaign in Haiti was implemented in Petite Anse and Cerca Carvajal. To evaluate vaccination coverage, barriers to vaccination, and adverse events following vaccination, we conducted a cluster survey. We enrolled 1,121 persons from Petite Anse and 809 persons from Cerca Carvajal, categorized by 3 age groups (1-4, 5-14, >15 years). Two-dose OCV coverage was 62.5% in Petite Anse and 76.8% in Cerca Carvajal. Two-dose coverage was lowest among persons >15 years of age. In Cerca Carvajal, coverage was significantly lower for male than female respondents (69% vs. 85%; p<0.001). No major adverse events were reported. The main reason for nonvaccination was absence during the campaign. Vaccination coverage after this campaign was acceptable and comparable to that resulting from campaigns implemented by nongovernmental organizations. Future campaigns should be tailored to reach adults who are not available during daytime hours.

  18. Coverage of Adequately Iodized Salt Is Suboptimal and Rice Fortification Using Public Distribution Channels Could Reach Low-Income Households: Findings from a Cross-Sectional Survey of Anganwadi Center Catchment Areas in Telangana, India.

    PubMed

    Wirth, James P; Leyvraz, Magali; Sodani, Prahlad R; Aaron, Grant J; Sharma, Narottam D; Woodruff, Bradley A

    2016-01-01

    Food fortification is a cost-effective approach to prevent and control of micronutrient deficiencies in India. A cross-sectional survey of children 0-35 months of age residing in the catchment areas of anganwadi centers in the state of Telangana was conducted to assess the coverage of adequately iodized salt and the potential for rice fortification. Salt samples were collected and tested for iodine concentration using iodometric titration. Information on demographics, household rice consumption, and Telangana's rice sector was collected and interpreted. In households of selected children, 79% of salt samples were found to be adequately iodized. Salt brand and district were significant predictors of inadequately iodized salt. Daily rice consumption among children and women averaged 122 grams and 321 grams per day, respectively. Approximately 28% of households reported consuming rice produced themselves or purchased from a local farmer, 65% purchased rice from a market or shop, 6% got rice from a public distribution system site, and 2% obtained it from a rice mill. In the catchment areas of Telangana's anganwadi centers, there is significant variation in the coverage of adequately iodized salt by district. Future surveys in Telangana should measure the coverage of salt iodization in the general population using quantitative methods. Nonetheless, increasing the adequacy of iodization of smaller salt manufacturers would help achieve universal salt iodization in Telangana. Despite high consumption of rice, our findings suggest that large-scale market-based rice fortification is not feasible in Telangana due to a large proportion of households producing their own rice and highly fragmented rice distribution. Distributing fortified rice via Telangana's public distribution system may be a viable approach to target low-income households, but would only reach a small proportion of the population in Telangana.

  19. Coverage of Adequately Iodized Salt Is Suboptimal and Rice Fortification Using Public Distribution Channels Could Reach Low-Income Households: Findings from a Cross-Sectional Survey of Anganwadi Center Catchment Areas in Telangana, India

    PubMed Central

    Wirth, James P.; Leyvraz, Magali; Sodani, Prahlad R.; Aaron, Grant J.; Sharma, Narottam D.; Woodruff, Bradley A.

    2016-01-01

    Food fortification is a cost-effective approach to prevent and control of micronutrient deficiencies in India. A cross-sectional survey of children 0–35 months of age residing in the catchment areas of anganwadi centers in the state of Telangana was conducted to assess the coverage of adequately iodized salt and the potential for rice fortification. Salt samples were collected and tested for iodine concentration using iodometric titration. Information on demographics, household rice consumption, and Telangana’s rice sector was collected and interpreted. In households of selected children, 79% of salt samples were found to be adequately iodized. Salt brand and district were significant predictors of inadequately iodized salt. Daily rice consumption among children and women averaged 122 grams and 321 grams per day, respectively. Approximately 28% of households reported consuming rice produced themselves or purchased from a local farmer, 65% purchased rice from a market or shop, 6% got rice from a public distribution system site, and 2% obtained it from a rice mill. In the catchment areas of Telangana’s anganwadi centers, there is significant variation in the coverage of adequately iodized salt by district. Future surveys in Telangana should measure the coverage of salt iodization in the general population using quantitative methods. Nonetheless, increasing the adequacy of iodization of smaller salt manufacturers would help achieve universal salt iodization in Telangana. Despite high consumption of rice, our findings suggest that large-scale market-based rice fortification is not feasible in Telangana due to a large proportion of households producing their own rice and highly fragmented rice distribution. Distributing fortified rice via Telangana’s public distribution system may be a viable approach to target low-income households, but would only reach a small proportion of the population in Telangana. PMID:27447925

  20. SU-E-T-639: Proton Dose Calculation for Irregular Motion Using a Sliding Interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phillips, J; Gueorguiev, G; Grassberger, C

    2015-06-15

    Purpose: While many techniques exist to evaluate dose to regularly moving lung targets, there are few available to calculate dose at tumor positions not present in the 4DCT. We have previously developed a method that extrapolates an existing dose to a new tumor location. In this abstract, we present a novel technique that accounts for relative anatomical shifts at the chest wall interface. We also utilize this procedure to simulate breathing motion functions on a cohort of eleven patients. Amplitudes exceeding the original range of motion were used to evaluate coverage using several aperture and smearing beam settings. Methods: Themore » water-equivalent depth (WED) technique requires an initial dose and CT image at the corresponding tumor position. Each dose volume was converted from its Cartesian geometry into a beam-specific radiological depth space. The sliding chest wall interface was determined by converting the lung contour into this same space. Any dose proximal to the initial boundary of the warped lung contour was held fixed, while the remaining distal dose was moved in the direction of motion along the interface. Results: V95 coverage was computed for each patient using the updated algorithm. Incorporation of the sliding motion yielded large dose differences, with gamma pass rates as low as 69.7% (3mm, 3%) and V95 coverage differences up to 2.0%. Clinical coverage was maintained for most patients with 5 mm excess simulated breathing motion, and up to 10 mm of excess motion was tolerated for a subset of patients and beam settings. Conclusion: We have established a method to determine the maximum allowable excess breathing motion for a given plan on a patient-by-patient basis. By integrating a sliding chest wall interface into our dose calculation technique, we have analyzed the robustness of breathing patterns that differ during treatment from at the time of 4DCT acquisition.« less

  1. Agonistic TAM-163 antibody targeting tyrosine kinase receptor-B: applying mechanistic modeling to enable preclinical to clinical translation and guide clinical trial design.

    PubMed

    Vugmeyster, Yulia; Rohde, Cynthia; Perreault, Mylene; Gimeno, Ruth E; Singh, Pratap

    2013-01-01

    TAM-163, an agonist monoclonal antibody targeting tyrosine receptor kinase-B (TrkB), is currently being investigated as a potential body weight modulatory agent in humans. To support the selection of the dose range for the first-in-human (FIH) trial of TAM-163, we conducted a mechanistic analysis of the pharmacokinetic (PK) and pharmacodynamic (PD) data (e.g., body weight gain) obtained in lean cynomolgus and obese rhesus monkeys following single doses ranging from 0.3 to 60 mg/kg. A target-mediated drug disposition (TMDD) model was used to describe the observed nonlinear PK and Emax approach was used to describe the observed dose-dependent PD effect. The TMDD model development was supported by the experimental determination of the binding affinity constant (9.4 nM) and internalization rate of the drug-target complex (2.08 h(-1)). These mechanistic analyses enabled linking of exposure, target (TrkB) coverage, and pharmacological activity (e.g., PD) in monkeys, and indicated that ≥ 38% target coverage (time-average) was required to achieve significant body weight gain in monkeys. Based on the scaling of the TMDD model from monkeys to humans and assuming similar relationship between the target coverage and pharmacological activity between monkey and humans, subcutaneous (SC) doses of 1 and 15 mg/kg in humans were projected to be the minimally and the fully pharmacologically active doses, respectively. Based on the minimal anticipated biological effect level (MABEL) approach for starting dose selection, the dose of 0.05 mg/kg (3 mg for a 60 kg human) SC was recommended as the starting dose for FIH trials, because at this dose level<10% target coverage was projected at Cmax (and all other time points). This study illustrates a rational mechanistic approach for the selection of FIH dose range for a therapeutic protein with a complex model of action.

  2. Whole-brain hippocampal sparing radiation therapy: Volume-modulated arc therapy vs intensity-modulated radiation therapy case study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Katrina, E-mail: Trinabena23@gmail.com; Lenards, Nishele; Holson, Janice

    The hippocampus is responsible for memory and cognitive function. An ongoing phase II clinical trial suggests that sparing dose to the hippocampus during whole-brain radiation therapy can help preserve a patient's neurocognitive function. Progressive research and advancements in treatment techniques have made treatment planning more sophisticated but beneficial for patients undergoing treatment. The aim of this study is to evaluate and compare hippocampal sparing whole-brain (HS-WB) radiation therapy treatment planning techniques using volume-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT). We randomly selected 3 patients to compare different treatment techniques that could be used for reducing dose to themore » hippocampal region. We created 2 treatment plans, a VMAT and an IMRT, from each patient's data set and planned on the Eclipse 11.0 treatment planning system (TPS). A total of 6 plans (3 IMRT and 3 VMAT) were created and evaluated for this case study. The physician contoured the hippocampus as per the Radiation Therapy Oncology Group (RTOG) 0933 protocol atlas. The organs at risk (OR) were contoured and evaluated for the plan comparison, which included the spinal cord, optic chiasm, the right and left eyes, lenses, and optic nerves. Both treatment plans produced adequate coverage on the planning target volume (PTV) while significantly reducing dose to the hippocampal region. The VMAT treatment plans produced a more homogenous dose distribution throughout the PTV while decreasing the maximum point dose to the target. However, both treatment techniques demonstrated hippocampal sparing when irradiating the whole brain.« less

  3. Analysis of esophageal-sparing treatment plans for patients with high-grade esophagitis.

    PubMed

    Niedzielski, Joshua; Bluett, Jaques B; Williamson, Ryan T; Liao, Zhongxing; Gomez, Daniel R; Court, Laurence E

    2013-07-08

    We retrospectively generated IMRT plans for 14 NSCLC patients who had experienced grade 2 or 3 esophagitis (CTCAE version 3.0). We generated 11-beam and reduced esophagus dose plan types to compare changes in the volume and length of esophagus receiving doses of 50, 55, 60, 65, and 70 Gy. Changes in planning target volume (PTV) dose coverage were also compared. If necessary, plans were renormalized to restore 95% PTV coverage. The critical organ doses examined were mean lung dose, mean heart dose, and volume of spinal cord receiving 50 Gy. The effect of interfractional motion was determined by applying a three-dimensional rigid shift to the dose grid. For the esophagus plan, the mean reduction in esophagus V50, V55, V60, V65, and V70 Gy was 2.8, 4.1, 5.9, 7.3, and 9.5 cm(3), respectively, compared with the clinical plan. The mean reductions in LE50, LE55, LE60, LE65, and LE70 Gy were 2.0, 3.0, 3.8, 4.0, and 4.6 cm, respectively. The mean heart and lung dose decreased 3.0 Gy and 2.4 Gy, respectively. The mean decreases in 90% and 95% PTV coverage were 1.7 Gy and 2.8 Gy, respectively. The normalized plans' mean reduction of esophagus V50, V55, V60, V65, and V70 Gy were 1.6, 2.0, 2.9, 3.9, and 5.5 cm(3), respectively, compared with the clinical plans. The normalized plans' mean reductions in LE50, LE55, LE60, LE65, and LE70 Gy were 4.9, 5.2, 5.4, 4.9, and 4.8 cm, respectively. The mean reduction in maximum esophagus dose with simulated interfractional motion was 3.0 Gy and 1.4 Gy for the clinical plan type and the esophagus plan type, respectively. In many cases, the esophagus dose can be greatly reduced while maintaining critical structure dose constraints. PTV coverage can be restored by increasing beam output, while still obtaining a dose reduction to the esophagus and maintaining dose constraints.

  4. Analysis of esophageal‐sparing treatment plans for patients with high‐grade esophagitis

    PubMed Central

    Bluett, Jaques B.; Williamson, Ryan T.; Liao, Zhongxing; Gomez, Daniel R.; Court, Laurence E.

    2013-01-01

    We retrospectively generated IMRT plans for 14 NSCLC patients who had experienced grade 2 or 3 esophagitis (CTCAE version 3.0). We generated 11‐beam and reduced esophagus dose plan types to compare changes in the volume and length of esophagus receiving doses of 50, 55, 60, 65, and 70 Gy. Changes in planning target volume (PTV) dose coverage were also compared. If necessary, plans were renormalized to restore 95% PTV coverage. The critical organ doses examined were mean lung dose, mean heart dose, and volume of spinal cord receiving 50 Gy. The effect of interfractional motion was determined by applying a three‐dimensional rigid shift to the dose grid. For the esophagus plan, the mean reduction in esophagus V50, V55, V60, V65, and V70 Gy was 2.8, 4.1, 5.9, 7.3, and 9.5 cm3, respectively, compared with the clinical plan. The mean reductions in LE50, LE55, LE60, LE65, and LE70 Gy were 2.0, 3.0, 3.8, 4.0, and 4.6 cm, respectively. The mean heart and lung dose decreased 3.0 Gy and 2.4 Gy, respectively. The mean decreases in 90% and 95% PTV coverage were 1.7 Gy and 2.8 Gy, respectively. The normalized plans’ mean reduction of esophagus V50, V55, V60, V65, and V70 Gy were 1.6, 2.0, 2.9, 3.9, and 5.5 cm3, respectively, compared with the clinical plans. The normalized plans’ mean reductions in LE50, LE55, LE60, LE65, and LE70 Gy were 4.9, 5.2, 5.4, 4.9, and 4.8 cm, respectively. The mean reduction in maximum esophagus dose with simulated interfractional motion was 3.0 Gy and 1.4 Gy for the clinical plan type and the esophagus plan type, respectively. In many cases, the esophagus dose can be greatly reduced while maintaining critical structure dose constraints. PTV coverage can be restored by increasing beam output, while still obtaining a dose reduction to the esophagus and maintaining dose constraints. PACS number: 87.53 Tf PMID:23835390

  5. Effectiveness of a smartphone app on improving immunization of children in rural Sichuan Province, China: a cluster randomized controlled trial.

    PubMed

    Chen, Li; Du, Xiaozhen; Zhang, Lin; van Velthoven, Michelle Helena; Wu, Qiong; Yang, Ruikan; Cao, Ying; Wang, Wei; Xie, Lihui; Rao, Xiuqin; Zhang, Yanfeng; Koepsell, Jeanne Catherine

    2016-08-31

    The aim of this study was to assess the effectiveness of an EPI smartphone application (EPI app) on improving vaccination coverage in rural Sichuan Province, China. This matched-pair cluster randomized controlled study included 32 village doctors, matched in 16 pairs, and took place from 2013 to 2015. Village doctors in the intervention group used the EPI app and reminder text messages while village doctors in the control group used their usual procedures and text messages. The primary outcome was full vaccination coverage with all five vaccines (1 dose of BCG, 3 doses of hepatitis B, 3 doses of OPV, 3 doses of DPT and 1 dose of measles vaccine), and the secondary outcome was coverage with each dose of the five individual vaccines. We also conducted qualitative interviews with village doctors to understand perceptions on using the EPI app and how this changed their vaccination work. The full vaccination coverage increased statistically significant from baseline to end-line in both the intervention (67 % [95 % CI:58-75 %] to 84 % [95 % CI:76-90 %], P = 0.028) and control group (71 % [95 % CI:62-79 %] to 82 % [95 % CI:74-88 %], P = 0.014). The intervention group had higher increase in full vaccination coverage from baseline to end-line compared to the control group (17 % vs 10 %), but this was not statistically significant (P = 0.164). Village doctors found it more convenient to use the EPI app to manage child vaccination and also reported saving time by looking up information of caregivers and contacting caregivers for overdue vaccinations quicker. However, village doctors found it hard to manage children who migrated out of the counties. This study showed that an app and text messages can be used by village doctors to improve full vaccination coverage, though no significant increase in vaccination coverage was found when assessing the effect of the app on its own. Village doctors using EPI app reported having improved their working efficiency of managing childhood vaccination. Future studies should be conducted to evaluate the impact of more integrated approach of mHealth intervention on child immunization. Chinese Clinical Trials Registry (ChiCTR): ChiCTR-TRC- 13003960 , registered on December 6, 2013.

  6. Estimating treatment coverage for people with substance use disorders: an analysis of data from the World Mental Health Surveys.

    PubMed

    Degenhardt, Louisa; Glantz, Meyer; Evans-Lacko, Sara; Sadikova, Ekaterina; Sampson, Nancy; Thornicroft, Graham; Aguilar-Gaxiola, Sergio; Al-Hamzawi, Ali; Alonso, Jordi; Helena Andrade, Laura; Bruffaerts, Ronny; Bunting, Brendan; Bromet, Evelyn J; Miguel Caldas de Almeida, José; de Girolamo, Giovanni; Florescu, Silvia; Gureje, Oye; Maria Haro, Josep; Huang, Yueqin; Karam, Aimee; Karam, Elie G; Kiejna, Andrzej; Lee, Sing; Lepine, Jean-Pierre; Levinson, Daphna; Elena Medina-Mora, Maria; Nakamura, Yosikazu; Navarro-Mateu, Fernando; Pennell, Beth-Ellen; Posada-Villa, José; Scott, Kate; Stein, Dan J; Ten Have, Margreet; Torres, Yolanda; Zarkov, Zahari; Chatterji, Somnath; Kessler, Ronald C

    2017-10-01

    Substance use is a major cause of disability globally. This has been recognized in the recent United Nations Sustainable Development Goals (SDGs), in which treatment coverage for substance use disorders is identified as one of the indicators. There have been no estimates of this treatment coverage cross-nationally, making it difficult to know what is the baseline for that SDG target. Here we report data from the World Health Organization (WHO)'s World Mental Health Surveys (WMHS), based on representative community household surveys in 26 countries. We assessed the 12-month prevalence of substance use disorders (alcohol or drug abuse/dependence); the proportion of people with these disorders who were aware that they needed treatment and who wished to receive care; the proportion of those seeking care who received it; and the proportion of such treatment that met minimal standards for treatment quality ("minimally adequate treatment"). Among the 70,880 participants, 2.6% met 12-month criteria for substance use disorders; the prevalence was higher in upper-middle income (3.3%) than in high-income (2.6%) and low/lower-middle income (2.0%) countries. Overall, 39.1% of those with 12-month substance use disorders recognized a treatment need; this recognition was more common in high-income (43.1%) than in upper-middle (35.6%) and low/lower-middle income (31.5%) countries. Among those who recognized treatment need, 61.3% made at least one visit to a service provider, and 29.5% of the latter received minimally adequate treatment exposure (35.3% in high, 20.3% in upper-middle, and 8.6% in low/lower-middle income countries). Overall, only 7.1% of those with past-year substance use disorders received minimally adequate treatment: 10.3% in high income, 4.3% in upper-middle income and 1.0% in low/lower-middle income countries. These data suggest that only a small minority of people with substance use disorders receive even minimally adequate treatment. At least three barriers are involved: awareness/perceived treatment need, accessing treatment once a need is recognized, and compliance (on the part of both provider and client) to obtain adequate treatment. Various factors are likely to be involved in each of these three barriers, all of which need to be addressed to improve treatment coverage of substance use disorders. These data provide a baseline for the global monitoring of progress of treatment coverage for these disorders as an indicator within the SDGs. © 2017 World Psychiatric Association.

  7. Estimating treatment coverage for people with substance use disorders: an analysis of data from the World Mental Health Surveys

    PubMed Central

    Degenhardt, Louisa; Glantz, Meyer; Evans‐Lacko, Sara; Sadikova, Ekaterina; Sampson, Nancy; Thornicroft, Graham; Aguilar‐Gaxiola, Sergio; Al‐Hamzawi, Ali; Alonso, Jordi; Helena Andrade, Laura; Bruffaerts, Ronny; Bunting, Brendan; Bromet, Evelyn J.; Miguel Caldas de Almeida, José; de Girolamo, Giovanni; Florescu, Silvia; Gureje, Oye; Maria Haro, Josep; Huang, Yueqin; Karam, Aimee; Karam, Elie G.; Kiejna, Andrzej; Lee, Sing; Lepine, Jean‐Pierre; Levinson, Daphna; Elena Medina‐Mora, Maria; Nakamura, Yosikazu; Navarro‐Mateu, Fernando; Pennell, Beth‐Ellen; Posada‐Villa, José; Scott, Kate; Stein, Dan J.; ten Have, Margreet; Torres, Yolanda; Zarkov, Zahari; Chatterji, Somnath; Kessler, Ronald C.; Adamowski, Tomasz; Aguilar‐Gaxiola, Sergio; Al‐Hamzawi, Ali; Al‐Kaisy, Mohammad; Alonso, Jordi; Altwaijri, Yasmin; Andrade, Laura Helena; Atwoli, Lukoye; Auerbach, Randy P.; Axinn, William G.; Benjet, Corina; Borges, Guilherme; Bromet, Evelyn J.; Bruffaerts, Ronny; Bunting, Brendan; Caldas de Almeida, José Miguel; Cardoso, Graça; Chardoul, Stephanie; Chatterji, Somnath; Filho, Alexandre Chiavegatto; Cia, Alfredo H.; Cuijpers, Pim; Degenhardt, Louisa; de Girolamo, Giovanni; de Graaf, Ron; de Jonge, Peter; Ebert, David D.; Evans‐Lacko, Sara; Fayyad, John; Florescu, Silvia; Galea, Sandro; Germine, Laura; Ghimire, Dirgha J.; Gilman, Stephen E.; Glantz, Meyer D.; Gluzman, Semyon; Gureje, Oye; Haro, Josep Maria; Harris, Meredith G.; He, Yanling; Hinkov, Hristo; Hu, Chi‐Yi; Huang, Yueqin; Karam, Aimee Nasser; Karam, Elie G.; Kawakami, Norito; Kessler, Ronald C.; Kiejna, Andrzej; Koenen, Karestan C.; Kovess‐Masfety, Viviane; Lara, Carmen; Lee, Sing; Lepine, Jean‐Pierre; Levav, Itzhak; Levinson, Daphna; Liu, Zhaorui; Martins, Silvia S.; McGrath, John J.; McLaughlin, Katie A.; Medina‐Mora, Maria Elena; Mneimneh, Zeina; Moskalewicz, Jacek; Navarro‐Mateu, Fernando; Nock, Matthew K.; O'Neill, Siobhan; Ormel, Johan; Pennell, Beth‐Ellen; Piazza, Marina; Piotrowski, Patryk; Posada‐Villa, José; Ruscio, Ayelet M.; Scott, Kate M.; Slade, Tim; Smoller, Jordan W.; Stagnaro, Juan Carlos; Stein, Dan J.; Street, Amy E.; Tachimori, Hisateru; ten Have, Margreet; Thornicroft, Graham; Torres, Yolanda; Vilagut, Gemma; Viana, Maria Carmen; Wells, Elisabeth; Williams, David R.; Williams, Michelle A.; Wojtyniak, Bogdan; Zaslavsky, Alan M.

    2017-01-01

    Substance use is a major cause of disability globally. This has been recognized in the recent United Nations Sustainable Development Goals (SDGs), in which treatment coverage for substance use disorders is identified as one of the indicators. There have been no estimates of this treatment coverage cross‐nationally, making it difficult to know what is the baseline for that SDG target. Here we report data from the World Health Organization (WHO)'s World Mental Health Surveys (WMHS), based on representative community household surveys in 26 countries. We assessed the 12‐month prevalence of substance use disorders (alcohol or drug abuse/dependence); the proportion of people with these disorders who were aware that they needed treatment and who wished to receive care; the proportion of those seeking care who received it; and the proportion of such treatment that met minimal standards for treatment quality (“minimally adequate treatment”). Among the 70,880 participants, 2.6% met 12‐month criteria for substance use disorders; the prevalence was higher in upper‐middle income (3.3%) than in high‐income (2.6%) and low/lower‐middle income (2.0%) countries. Overall, 39.1% of those with 12‐month substance use disorders recognized a treatment need; this recognition was more common in high‐income (43.1%) than in upper‐middle (35.6%) and low/lower‐middle income (31.5%) countries. Among those who recognized treatment need, 61.3% made at least one visit to a service provider, and 29.5% of the latter received minimally adequate treatment exposure (35.3% in high, 20.3% in upper‐middle, and 8.6% in low/lower‐middle income countries). Overall, only 7.1% of those with past‐year substance use disorders received minimally adequate treatment: 10.3% in high income, 4.3% in upper‐middle income and 1.0% in low/lower‐middle income countries. These data suggest that only a small minority of people with substance use disorders receive even minimally adequate treatment. At least three barriers are involved: awareness/perceived treatment need, accessing treatment once a need is recognized, and compliance (on the part of both provider and client) to obtain adequate treatment. Various factors are likely to be involved in each of these three barriers, all of which need to be addressed to improve treatment coverage of substance use disorders. These data provide a baseline for the global monitoring of progress of treatment coverage for these disorders as an indicator within the SDGs. PMID:28941090

  8. Drug Coverage Surveys for Neglected Tropical Diseases: 10 Years of Field Experience

    PubMed Central

    Worrell, Caitlin; Mathieu, Els

    2012-01-01

    Mass drug administration is one of the public health strategies recommended by the World Health Organization for the control and elimination of seven neglected tropical diseases (NTDs). Because adequate coverage is vital to achieve program goals, periodically conducting surveys to validate reported coverage to guide NTD programs is recommended. Over the past decade, the Centers for Disease Control and Prevention (CDC) and collaborators conducted more than 30 two-stage cluster household surveys across three continents. The questionnaires gathered coverage data and information relevant to improving NTD programs including NTD-related attitudes and practices. From the 37 coverage survey estimates obtained in those surveys, 73.3% indicated an over reporting of coverage, including all three that assessed school-based distributions. It took an average of 1 week to conduct a survey. Our experiences led us to conclude that coverage surveys are useful and feasible tools to ensure NTD elimination and control goals are reached. PMID:22855750

  9. Quantification of interplay and gradient effects for lung stereotactic ablative radiotherapy (SABR) treatments

    PubMed Central

    2016-01-01

    This study quantified the interplay and gradient effects on GTV dose coverage for 3D CRT, dMLC IMRT, and VMAT SABR treatments for target amplitudes of 5–30 mm using 3DVH v3.1 software incorporating 4D Respiratory MotionSim (4D RMS) module. For clinically relevant motion periods (5 s), the interplay effect was small, with deviations in the minimum dose covering the target volume (D99%) of less than ±2.5% for target amplitudes up to 30 mm. Increasing the period to 60 s resulted in interplay effects of up to ±15.0% on target D99% dose coverage. The gradient effect introduced by target motion resulted in deviations of up to ±3.5% in D99% target dose coverage. VMAT treatments showed the largest deviation in dose metrics, which was attributed to the long delivery times in comparison to dMLC IMRT. Retrospective patient analysis indicated minimal interplay and gradient effects for patients treated with dMLC IMRT at the NCCI. PACS numbers: 87.55.km, 87.56.Fc PMID:26894347

  10. Intensity-modulated radiotherapy improves lymph node coverage and dose to critical structures compared with three-dimensional conformal radiation therapy in clinically localized prostate cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang-Chesebro, Alice; Xia Ping; Coleman, Joy

    2006-11-01

    Purpose: The aim of this study was to quantify gains in lymph node coverage and critical structure dose reduction for whole-pelvis (WP) and extended-field (EF) radiotherapy in prostate cancer using intensity-modulated radiotherapy (IMRT) compared with three-dimensional conformal radiotherapy (3DCRT) for the first treatment phase of 45 Gy in the concurrent treatment of lymph nodes and prostate. Methods and Materials: From January to August 2005, 35 patients with localized prostate cancer were treated with pelvic IMRT; 7 had nodes defined up to L5-S1 (Group 1), and 28 had nodes defined above L5-S1 (Group 2). Each patient had 2 plans retrospectively generated:more » 1 WP 3DCRT plan using bony landmarks, and 1 EF 3DCRT plan to cover the vascular defined volumes. Dose-volume histograms for the lymph nodes, rectum, bladder, small bowel, and penile bulb were compared by group. Results: For Group 1, WP 3DCRT missed 25% of pelvic nodes with the prescribed dose 45 Gy and missed 18% with the 95% prescribed dose 42.75 Gy, whereas WP IMRT achieved V{sub 45Gy} = 98% and V{sub 42.75Gy} = 100%. Compared with WP 3DCRT, IMRT reduced bladder V{sub 45Gy} by 78%, rectum V{sub 45Gy} by 48%, and small bowel V{sub 45Gy} by 232 cm{sup 3}. EF 3DCRT achieved 95% coverage of nodes for all patients at high cost to critical structures. For Group 2, IMRT decreased bladder V{sub 45Gy} by 90%, rectum V{sub 45Gy} by 54% and small bowel V{sub 45Gy} by 455 cm{sup 3} compared with EF 3DCRT. Conclusion: In this study WP 3DCRT missed a significant percentage of pelvic nodes. Although EF 3DCRT achieved 95% pelvic nodal coverage, it increased critical structure doses. IMRT improved pelvic nodal coverage while decreasing dose to bladder, rectum, small bowel, and penile bulb. For patients with extended node involvement, IMRT especially decreases small bowel dose.« less

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krayenbuehl, Jerome; Hartmann, Matthias; Lomax, Anthony J.

    Purpose: To perform comparative planning for intensity-modulated radiotherapy (IMRT) and proton therapy (PT) for malignant pleural mesothelioma after radical surgery. Methods and Materials: Eight patients treated with IMRT after extrapleural pleuropneumonectomy (EPP) were replanned for PT, comparing dose homogeneity, target volume coverage, and mean and maximal dose to organs at risk. Feasibility of PT was evaluated regarding the dose distribution with respect to air cavities after EPP. Results: Dose coverage and dose homogeneity of the planning target volume (PTV) were significantly better for PT than for IMRT regarding the volume covered by >95% (V95) for the high-dose PTV. The meanmore » dose to the contralateral kidney, ipsilateral kidney, contralateral lung, liver, and heart and spinal cord dose were significantly reduced with PT compared with IMRT. After EPP, air cavities were common (range, 0-850 cm{sup 3}), decreasing from 0 to 18.5 cm{sup 3}/day. In 2 patients, air cavity changes during RT decreased the generalized equivalent uniform dose (gEUD) in the case of using an a value of < - 10 to the PTV2 to <2 Gy in the presence of changing cavities for PT, and to 40 Gy for IMRT. Small changes were observed for gEUD of PTV1 because PTV1 was reached by the beams before air. Conclusion: Both PT and IMRT achieved good target coverage and dose homogeneity. Proton therapy accomplished additional dose sparing of most organs at risk compared with IMRT. Proton therapy dose distributions were more susceptible to changing air cavities, emphasizing the need for adaptive RT and replanning.« less

  12. NSW annual immunisation coverage report, 2010.

    PubMed

    Hull, Brynley; Dey, Aditi; Campbell-Lloyd, Sue; Menzies, Robert I; McIntyre, Peter B

    2011-11-01

    This annual report, the second in the series, documents trends in immunisation coverage in NSW for children, adolescents and the elderly, to the end of 2010. Data from the Australian Childhood Immunisation Register, the NSW School Immunisation Program and the NSW Population Health Survey were used to calculate various measures of population coverage, coverage for Aboriginal children and vaccination timeliness for all children. Over 90% coverage has been reached for children at 12 and 24 months of age. For children at 5 years of age there was an improvement during 2010 in timeliness for vaccines due at 4 years and coverage almost reached 90%. Delayed receipt of vaccines is still an issue for Aboriginal children. For adolescents, there is good coverage for the first and second doses of human papillomavirus vaccine and the dose of diphtheria, tetanus and acellular pertussis. The pneumococcal vaccination rate in the elderly has been steadily rising, although it has remained lower than the influenza coverage estimates. Completion of the recommended immunisation schedule at the earliest appropriate age should be the next public health goal at both the state and local health district level. Official coverage assessments for 'fully immunised' should include the 7-valent pneumococcal conjugate and meningococcal C vaccines, and wider dissemination should be considered.

  13. An Audit to Evaluate the Image Quality of Magnetic Resonance of Knee at Radiology Department of a Tertiary Care Hospital.

    PubMed

    Mansoor, Ali; Ramzan, Amaila; Chaudhary, Aamer Nadeem

    2017-04-01

    light of recommendations of ACR. Aclinical audit. Department of Radiology, Jinnah Hospital, Lahore, from August 2015 to February 2016. Scans of 20 patients who underwent MRI of knee in August 2015 were studied retrospectively to assess the quality of images obtained in the first audit. Based on the findings of this audit, recommendations were made and re audit was done 6 months later in February 2016 to look for improvement in local practice. In the first audit, images were acquired in all the three necessary planes and the sagittal and coronal images had appropriate slice thickness, interslice gap as well as adequate anatomical coverage in all the patients. However, FOV (field of view) was appropriately set in 66% of cases in axial plane, 5% in sagittal plane, and 0% in coronal plane. Also, the anatomical coverage was not upto the mark in axial plane with 13 studies (66%) having adequate superior coverage, and 16 cases (80%) having recommended inferior anatomical coverage. The re audit performed 6 months later showed improvement with 100% compliance to standards. The first audit showed many shortcomings in acquiring of MRI data in patients undergoing knee MRI with FOV requiring a decrease in all planes and anatomical coverage increase in axial plane. These recommendations were made in departmental meetings and re-audit was done after 6 months. This second audit showed 100 % compliance.

  14. SU-F-T-404: Dosimetric Advantages of Flattening Free Beams to Prone Accelerated Partial Breast Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Galavis, P; Barbee, D; Jozsef, G

    2016-06-15

    Purpose: Prone accelerated partial breast irradiation (APBI) results in dose reduction to the heart and lung. Flattening filter free beams (FFF) reduce out of field dose due to the reduced scatter from the removal of the flattening filter and reduce the buildup region. The aim of this work is to evaluate the dosimetric advantages of FFF beams to prone APBI target coverage and reduction in dose to organs at risk. Methods: Fifteen clinical prone APBI cases using flattened photon beams were retrospectively re-planned in Eclipse-TPS using FFF beams. FFF plans were designed to provide equivalent target coverage with similar hotspotsmore » using the same field arrangements, resulting in comparable target DVHs. Both plans were transferred to a prone breast phantom and delivered on Varian-Edge-Linac. GafChromic-film was placed in the coronal plane of the phantom, partially overlapping the treatment field and extending into OARs to compare dose profiles from both plans. Results: FFF plans were comparable to the clinical plans with maximum doses of (108.3±2.3)% and (109.2±2.4)% and mean doses of (104.5±1.0)% and (104.6±1.2)%, respectively. Similar mean dose doses to the heart and contralateral lungs were observed from both plans, whereas the mean dose to the contra-lateral breast was (2.79±1.18) cGy and (2.86±1.40) cGy for FFF and clinical plans respectively. However for both plans the error between calculated and measured doses at 4 cm from the field edge was 10%. Conclusion: The results showed that FFF beams in prone APBI provide dosimetrically equivalent target coverage and improved coverage in superficial target due to softer energy spectra. Film analysis showed that the TPS underestimates dose outside field edges for both cases. The FFF measured plans showed less dose outside the beam that might reduce the probability of secondary cancers in the contralateral breast.« less

  15. Coverage of childhood vaccination among children aged 12-23 months, Tamil Nadu, 2015, India

    PubMed Central

    Murhekar, Manoj V.; Kamaraj, P.; Kanagasabai, K.; Elavarasu, G.; Rajasekar, T. Daniel; Boopathi, K.; Mehendale, Sanjay

    2017-01-01

    Background & objectives: District-Level Household Survey-4 (DLHS-4) indicated that during 2012-2013, only 56 per cent of children aged 12-23 months in Tamil Nadu were fully vaccinated, which were lesser than those reported in earlier national surveys. We, therefore, conducted cluster surveys to estimate coverage of childhood vaccination in the State, and also to identify the factors associated with low coverage. Methods: Cross-sectional surveys were conducted in 15 strata [municipal corporation non-slum (n=1), municipal corporation slum (n=1), hilly (n=1), rural (n=6) and urban (n=6)]. From each stratum, 30 clusters were selected using probability proportional to the population size linear systematic sampling; seven children aged 12-23 months were selected from each cluster and their mothers/care-takers were interviewed to collect information about vaccination status of the child. A child was considered fully vaccinated if he/she received bacillus Calmette-Guérin (BCG), three doses of pentavalent, three doses of oral polio vaccine and one dose of measles vaccine, and appropriately vaccinated if all vaccine doses were given at right age and with right interval. Further, coverage of fully vaccinated children (FVC) as per vaccination cards or mothers’ recall, validated coverage of FVC (V-FVC) among those having cards, and coverage of appropriately vaccinated children (AVC) were estimated using survey data analysis module with appropriate sampling weights. Results: A total of 3150 children were surveyed, of them 2528 (80.3%) had vaccination card. The weighted coverage of FVC, V-FVC and AVC in the State was 79.9 per cent [95% confidence interval (CI): 78.2-81.5], 78.8 per cent (95% CI: 76.9-80.5) and 69.7 per cent (95% CI: 67.7-71.7), respectively. The coverage of individual vaccine ranged between 84 per cent (measles) and 99.8 per cent (BCG). About 12 per cent V-FVC were not vaccinated as per the vaccination schedule. Interpretation & conclusions: The coverage of FVC in Tamil Nadu was high, with about 80 per cent children completing primary vaccination. Efforts to increase vaccination coverage in the State need to focus on educating vaccinators about the need to adhere to the national vaccination schedule and strengthening supervision to ensure that children are vaccinated appropriately. PMID:28749402

  16. Coverage of childhood vaccination among children aged 12-23 months, Tamil Nadu, 2015, India.

    PubMed

    Murhekar, Manoj V; Kamaraj, P; Kanagasabai, K; Elavarasu, G; Rajasekar, T Daniel; Boopathi, K; Mehendale, Sanjay

    2017-03-01

    District-Level Household Survey-4 (DLHS-4) indicated that during 2012-2013, only 56 per cent of children aged 12-23 months in Tamil Nadu were fully vaccinated, which were lesser than those reported in earlier national surveys. We, therefore, conducted cluster surveys to estimate coverage of childhood vaccination in the State, and also to identify the factors associated with low coverage. Cross-sectional surveys were conducted in 15 strata [municipal corporation non-slum (n=1), municipal corporation slum (n=1), hilly (n=1), rural (n=6) and urban (n=6)]. From each stratum, 30 clusters were selected using probability proportional to the population size linear systematic sampling; seven children aged 12-23 months were selected from each cluster and their mothers/care-takers were interviewed to collect information about vaccination status of the child. A child was considered fully vaccinated if he/she received bacillus Calmette-Guérin (BCG), three doses of pentavalent, three doses of oral polio vaccine and one dose of measles vaccine, and appropriately vaccinated if all vaccine doses were given at right age and with right interval. Further, coverage of fully vaccinated children (FVC) as per vaccination cards or mothers' recall, validated coverage of FVC (V-FVC) among those having cards, and coverage of appropriately vaccinated children (AVC) were estimated using survey data analysis module with appropriate sampling weights. A total of 3150 children were surveyed, of them 2528 (80.3%) had vaccination card. The weighted coverage of FVC, V-FVC and AVC in the State was 79.9 per cent [95% confidence interval (CI): 78.2-81.5], 78.8 per cent (95% CI: 76.9-80.5) and 69.7 per cent (95% CI: 67.7-71.7), respectively. The coverage of individual vaccine ranged between 84 per cent (measles) and 99.8 per cent (BCG). About 12 per cent V-FVC were not vaccinated as per the vaccination schedule. The coverage of FVC in Tamil Nadu was high, with about 80 per cent children completing primary vaccination. Efforts to increase vaccination coverage in the State need to focus on educating vaccinators about the need to adhere to the national vaccination schedule and strengthening supervision to ensure that children are vaccinated appropriately.

  17. Stereotactic radiotherapy of intrapulmonary lesions: comparison of different dose calculation algorithms for Oncentra MasterPlan®.

    PubMed

    Troeller, Almut; Garny, Sylvia; Pachmann, Sophia; Kantz, Steffi; Gerum, Sabine; Manapov, Farkhad; Ganswindt, Ute; Belka, Claus; Söhn, Matthias

    2015-02-22

    The use of high accuracy dose calculation algorithms, such as Monte Carlo (MC) and Collapsed Cone (CC) determine dose in inhomogeneous tissue more accurately than pencil beam (PB) algorithms. However, prescription protocols based on clinical experience with PB are often used for treatment plans calculated with CC. This may lead to treatment plans with changes in field size (FS) and changes in dose to organs at risk (OAR), especially for small tumor volumes in lung tissue treated with SABR. We re-evaluated 17 3D-conformal treatment plans for small intrapulmonary lesions with a prescription of 60 Gy in fractions of 7.5 Gy to the 80% isodose. All treatment plans were initially calculated in Oncentra MasterPlan® using a PB algorithm and recalculated with CC (CCre-calc). Furthermore, a CC-based plan with coverage similar to the PB plan (CCcov) and a CC plan with relaxed coverage criteria (CCclin), were created. The plans were analyzed in terms of Dmean, Dmin, Dmax and coverage for GTV, PTV and ITV. Changes in mean lung dose (MLD), V10Gy and V20Gy were evaluated for the lungs. The re-planned CC plans were compared to the original PB plans regarding changes in total monitor units (MU) and average FS. When PB plans were recalculated with CC, the average V60Gy of GTV, ITV and PTV decreased by 13.2%, 19.9% and 41.4%, respectively. Average Dmean decreased by 9% (GTV), 11.6% (ITV) and 14.2% (PTV). Dmin decreased by 18.5% (GTV), 21.3% (ITV) and 17.5% (PTV). Dmax declined by 7.5%. PTV coverage correlated with PTV volume (p < 0.001). MLD, V10Gy, and V20Gy were significantly reduced in the CC plans. Both, CCcov and CCclin had significantly increased MUs and FS compared to PB. Recalculation of PB plans for small lung lesions with CC showed a strong decline in dose and coverage in GTV, ITV and PTV, and declined dose in the lung. Thus, switching from a PB algorithm to CC, while aiming to obtain similar target coverage, can be associated with application of more MU and extension of radiotherapy fields, causing greater OAR exposition.

  18. Uptake and timeliness of rotavirus vaccination in Norway: The first year post-introduction.

    PubMed

    Valcarcel Salamanca, Beatriz; Hagerup-Jenssen, Maria Elisabeth; Flem, Elmira

    2016-09-07

    To minimise vaccine-associated risk of intussusception following rotavirus vaccination, Norway adopted very strict age limits for initiating and completing the vaccine series at the time rotavirus vaccination was included in the national immunisation programme, October 2014. Although Norway has a high coverage for routine childhood vaccines, these stringent age limits could negatively affect rotavirus coverage. We documented the status and impact of rotavirus vaccination on other infant vaccines during the first year after its introduction. We used individual vaccination data from the national immunisation register to calculate coverage for rotavirus and other vaccines and examine adherence with the recommended schedules. We identified factors associated with completing the full rotavirus series by performing multiple logistic regression analyses. We also evaluated potential changes in uptake and timeliness of other routine vaccines after the introduction of rotavirus vaccine using the Kaplan-Meier method. The national coverage for rotavirus vaccine achieved a year after the introduction was 89% for one dose and 82% for two doses, respectively. Among fully rotavirus-vaccinated children, 98% received both doses within the upper age limit and 90% received both doses according to the recommended schedule. The child's age at the initiation of rotavirus series and being vaccinated with diphtheria, tetanus, pertussis, polio and Haemophilus influenzae type b (DTaP/IPV/Hib) and pneumococcal vaccines were the strongest predictors of completing the full rotavirus series. No major changes in uptake and timeliness of other paediatric vaccines were observed after introduction of rotavirus vaccine. Norway achieved a high national coverage and excellent adherence with the strict age limits for rotavirus vaccine administration during the first year of introduction, indicating robustness of the national immunisation programme. Rotavirus vaccination did not impact coverage or timeliness of other infant vaccines. Copyright © 2016. Published by Elsevier Ltd.

  19. Recent resurgence of mumps in the United States.

    PubMed

    Dayan, Gustavo H; Quinlisk, M Patricia; Parker, Amy A; Barskey, Albert E; Harris, Meghan L; Schwartz, Jennifer M Hill; Hunt, Kae; Finley, Carol G; Leschinsky, Dennis P; O'Keefe, Anne L; Clayton, Joshua; Kightlinger, Lon K; Dietle, Eden G; Berg, Jeffrey; Kenyon, Cynthia L; Goldstein, Susan T; Stokley, Shannon K; Redd, Susan B; Rota, Paul A; Rota, Jennifer; Bi, Daoling; Roush, Sandra W; Bridges, Carolyn B; Santibanez, Tammy A; Parashar, Umesh; Bellini, William J; Seward, Jane F

    2008-04-10

    The widespread use of a second dose of mumps vaccine among U.S. schoolchildren beginning in 1990 was followed by historically low reports of mumps cases. A 2010 elimination goal was established, but in 2006 the largest mumps outbreak in two decades occurred in the United States. We examined national data on mumps cases reported during 2006, detailed case data from the most highly affected states, and vaccination-coverage data from three nationwide surveys. A total of 6584 cases of mumps were reported in 2006, with 76% occurring between March and May. There were 85 hospitalizations, but no deaths were reported; 85% of patients lived in eight contiguous midwestern states. The national incidence of mumps was 2.2 per 100,000, with the highest incidence among persons 18 to 24 years of age (an incidence 3.7 times that of all other age groups combined). In a subgroup analysis, 83% of these patients reported current college attendance. Among patients in eight highly affected states with known vaccination status, 63% overall and 84% between the ages of 18 and 24 years had received two doses of mumps vaccine. For the 12 years preceding the outbreak, national coverage of one-dose mumps vaccination among preschoolers was 89% or more nationwide and 86% or more in highly affected states. In 2006, the national two-dose coverage among adolescents was 87%, the highest in U.S. history. Despite a high coverage rate with two doses of mumps-containing vaccine, a large mumps outbreak occurred, characterized by two-dose vaccine failure, particularly among midwestern college-age adults who probably received the second dose as schoolchildren. A more effective mumps vaccine or changes in vaccine policy may be needed to avert future outbreaks and achieve the elimination of mumps. Copyright 2008 Massachusetts Medical Society.

  20. Vaccine exemptions and the kindergarten vaccination coverage gap.

    PubMed

    Smith, Philip J; Shaw, Jana; Seither, Ranee; Lopez, Adriana; Hill, Holly A; Underwood, Mike; Knighton, Cynthia; Zhao, Zhen; Ravanam, Megha Shah; Greby, Stacie; Orenstein, Walter A

    2017-09-25

    Vaccination requirements for kindergarten entry vary by state, but all states require 2 doses of measles containing vaccine (MCV) at kindergarten entry. To assess (i) national MCV vaccination coverage for children who had attended kindergarten; (ii) the extent to which undervaccination after kindergarten entry is attributable to parents' requests for an exemption; (iii) the extent to which undervaccinated children had missed opportunities to be administered missing vaccine doses among children whose parent did not request an exemption; and (iv) the vaccination coverage gap between the "highest achievable" MCV coverage and actual MCV coverage among children who had attended kindergarten. A national survey of 1465 parents of 5-7year-old children was conducted during October 2013 through March 2014. Vaccination coverage estimates are based provider-reported vaccination histories. Children have a "missed opportunity" for MCV if they were not up-to-date and if there were dates on which other vaccines were administered but not MCV. The "highest achievable" MCV vaccination coverage rate is 100% minus the sum of the percentages of (i) undervaccinated children with parents who requested an exemption; and (ii) undervaccinated children with parents who did not request an exemption and whose vaccination statuses were assessed during a kindergarten grace period or period when they were provisionally enrolled in kindergarten. Among all children undervaccinated for MCV, 2.7% were attributable to having a parent who requested an exemption. Among children who were undervaccinated for MCV and whose parent did not request an exemption, 41.6% had a missed opportunity for MCV. The highest achievable MCV coverage was 98.6%, actual MCV coverage was 90.9%, and the kindergarten vaccination gap was 7.7%. Vaccination coverage may be increased by schools fully implementing state kindergarten vaccination laws, and by providers assessing children's vaccination status at every clinic visit, and administering missed vaccine doses. Published by Elsevier Ltd.

  1. A radiotherapy technique to limit dose to neural progenitor cell niches without compromising tumor coverage

    PubMed Central

    Redmond, Kristin J.; Achanta, Pragathi; Grossman, Stuart A.; Armour, Michael; Reyes, Juvenal; Kleinberg, Lawrence; Tryggestad, Erik; Quinones-Hinojosa, Alfredo

    2015-01-01

    Radiation therapy (RT) for brain tumors is associated with neurocognitive toxicity which may be a result of damage to neural progenitor cells (NPCs). We present a novel technique to limit the radiation dose to NPC without compromising tumor coverage. A study was performed in mice to examine the rationale and another was conducted in humans to determine its feasibility. C57BL/6 mice received localized radiation using a dedicated animal irradiation system with on-board CT imaging with either: (1) Radiation which spared NPC containing regions; (2) Radiation which did not spare these niches; or (3) Sham irradiation. Mice were sacrificed 24 h later and the brains were processed for immunohistochemical Ki-67 staining. For the human component of the study, 33 patients with primary brain tumors were evaluated. Two intensity modulated radiotherapy (IMRT) plans were retrospectively compared: a standard clinical plan and a plan which spares NPC regions while maintaining the same dose coverage of the tumor. The change in radiation dose to the contralateral NPC-containing regions was recorded. In the mouse model, non-NPC-sparing radiation treatment resulted in a significant decrease in the number of Ki67+ cells in dentate gyrus (DG) (P = 0.008) and subventricular zone (SVZ) (P = 0.005) compared to NPC-sparing radiation treatment. In NPC-sparing clinical plans, NPC regions received significantly lower radiation dose with no clinically relevant changes in tumor coverage. This novel radiation technique should significantly reduce radiation doses to NPC containing regions of the brain which may reduce neurocognitive deficits following RT for brain tumors. PMID:21327710

  2. The Gradual Expansion Muscle Flap

    DTIC Science & Technology

    2014-01-01

    acute shortening and angulation of the tibia and rotational muscle flap coverage and split thickness skin grafting of the soft tissue defect...is also amenable to split-thickness skin grafting after tissue incorporation.11 In addition to donor site morbidity, free tissue transfer is dependent...necessary soft tissue coverage. In the second stage, after the flap has adequately set and overlying skin graft has full adherence, a Taylor Spatial

  3. Electron intensity modulation for mixed-beam radiation therapy with an x-ray multi-leaf collimator

    NASA Astrophysics Data System (ADS)

    Weinberg, Rebecca

    The current standard treatment for head and neck cancer at our institution uses intensity-modulated x-ray therapy (IMRT), which improves target coverage and sparing of critical structures by delivering complex fluence patterns from a variety of beam directions to conform dose distributions to the shape of the target volume. The standard treatment for breast patients is field-in-field forward-planned IMRT, with initial tangential fields and additional reduced-weight tangents with blocking to minimize hot spots. For these treatment sites, the addition of electrons has the potential of improving target coverage and sparing of critical structures due to rapid dose falloff with depth and reduced exit dose. In this work, the use of mixed-beam therapy (MBT), i.e., combined intensity-modulated electron and x-ray beams using the x-ray multi-leaf collimator (MLC), was explored. The hypothesis of this study was that addition of intensity-modulated electron beams to existing clinical IMRT plans would produce MBT plans that were superior to the original IMRT plans for at least 50% of selected head and neck and 50% of breast cases. Dose calculations for electron beams collimated by the MLC were performed with Monte Carlo methods. An automation system was created to facilitate communication between the dose calculation engine and the treatment planning system. Energy and intensity modulation of the electron beams was accomplished by dividing the electron beams into 2x2-cm2 beamlets, which were then beam-weight optimized along with intensity-modulated x-ray beams. Treatment plans were optimized to obtain equivalent target dose coverage, and then compared with the original treatment plans. MBT treatment plans were evaluated by participating physicians with respect to target coverage, normal structure dose, and overall plan quality in comparison with original clinical plans. The physician evaluations did not support the hypothesis for either site, with MBT selected as superior in 1 out of the 15 head and neck cases (p=1) and 6 out of 18 breast cases (p=0.95). While MBT was not shown to be superior to IMRT, reductions were observed in doses to critical structures distal to the target along the electron beam direction and to non-target tissues, at the expense of target coverage and dose homogeneity.

  4. SU-G-BRA-16: Target Dose Comparison for Dynamic MLC Tracking and Mid- Ventilation Planning in Lung Radiotherapy Subject to Intrafractional Baseline Drifts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Menten, MJ; Fast, MF; Nill, S

    Purpose: Lung tumor motion during radiotherapy can be accounted for by expanded treatment margins, for example using a mid-ventilation planning approach, or by localizing the tumor in real-time and adapting the treatment beam with multileaf collimator (MLC) tracking. This study evaluates the effect of intrafractional changes in the average tumor position (baseline drifts) on these two treatment techniques. Methods: Lung stereotactic treatment plans (9-beam IMRT, 54Gy/3 fractions, mean treatment time: 9.63min) were generated for three patients: either for delivery with MLC tracking (isotropic GTV-to-PTV margin: 2.6mm) or planned with a mid-ventilation approach and delivered without online motion compensation (GTV-to-PTV margin:more » 4.4-6.3mm). Delivery to a breathing patient was simulated using DynaTrack, our in-house tracking and delivery software. Baseline drifts in cranial and posterior direction were simulated at a rate of 0.5, 1.0 or 1.5mm/min. For dose reconstruction, the corresponding 4DCT phase was selected for each time point of the delivery. Baseline drifts were accounted for by rigidly shifting the CT to ensure correct relative beam-to-target positioning. Afterwards, the doses delivered to each 4DCT phase were accumulated deformably on the mid-ventilation phase using research RayStation v4.6 and dose coverage of the GTV was evaluated. Results: When using the mid-ventilation planning approach, dose coverage of the tumor deteriorated substantially in the presence of baseline drifts. The reduction in D98% coverage of the GTV in a single fraction ranged from 0.4-1.2, 0.6-3.3 and 4.5-6.2Gy, respectively, for the different drift rates. With MLC tracking the GTV D98% coverage remained unchanged (+/− 0.1Gy) regardless of drift. Conclusion: Intrafractional baseline drifts reduce the tumor dose in treatments based on mid-ventilation planning. In rare, large target baseline drifts tumor dose coverage may drop below the prescription, potentially affecting clinical outcome in hypofractionated treatment protocols. Dynamic MLC tracking preserves tumor dose coverage even in the presence of extreme baseline drifts. We acknowledge financial and technical support of the MLC tracking research from Elekta AB. Research at ICR is supported by CRUK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR. MFF is supported by CRUK under Programme C33589/A19908.« less

  5. Dosimetric comparison between conventional and conformal radiotherapy for carcinoma cervix: Are we treating the right volumes?

    PubMed Central

    Goswami, Jyotirup; Patra, Niladri B.; Sarkar, Biplab; Basu, Ayan; Pal, Santanu

    2013-01-01

    Background and Purpose: Conventional portals, based on bony anatomy, for external beam radiotherapy for cervical cancer have been repeatedly demonstrated as inadequate. Conversely, with image-based conformal radiotherapy, better target coverage may be offset by the greater toxicities and poorer compliance associated with treating larger volumes. This study was meant to dosimetrically compare conformal and conventional radiotherapy. Materials and Methods: Five patients of carcinoma cervix underwent planning CT scan with IV contrast and targets, and organs at risk (OAR) were contoured. Two sets of plans-conventional and conformal were generated for each patient. Field sizes were recorded, and dose volume histograms of both sets of plans were generated and compared on the basis of target coverage and OAR sparing. Results: Target coverage was significantly improved with conformal plans though field sizes required were significantly larger. On the other hand, dose homogeneity was not significantly improved. Doses to the OARs (rectum, urinary bladder, and small bowel) were not significantly different across the 2 arms. Conclusion: Three-dimensional conformal radiotherapy gives significantly better target coverage, which may translate into better local control and survival. On the other hand, it also requires significantly larger field sizes though doses to the OARs are not significantly increased. PMID:24455584

  6. Immunisation coverage, 2012.

    PubMed

    Hull, Brynley P; Dey, Aditi; Menzies, Rob I; Brotherton, Julia M; McIntyre, Peter B

    2014-09-30

    This, the 6th annual immunisation coverage report, documents trends during 2012 for a range of standard measures derived from Australian Childhood Immunisation Register (ACIR) data, and National Human Papillomavirus (HPV) Vaccination Program Register data. These include coverage at standard age milestones and for individual vaccines included on the National Immunisation Program (NIP) and coverage in adolescents and adults. The proportion of Australian children 'fully vaccinated' at 12, 24 and 60 months of age was 91.7%, 92.5% and 91.2%, respectively. For vaccines available on the NIP but not assessed during 2012 for 'fully vaccinated' status or for eligibility for incentive payments (rotavirus and pneumococcal at 12 months and meningococcal C and varicella at 24 months) coverage varied. Although pneumococcal vaccine had similar coverage at 12 months to other vaccines, coverage was lower for rotavirus at 12 months (83.6%) and varicella at 24 months (84.4%). Although 'fully vaccinated' coverage at 12 months of age was lower among Indigenous children than non-Indigenous children in all jurisdictions, the extent of the difference varied, reaching a 15 percentage point differential in South Australia but only a 0.4 percentage point differential in the Northern Territory. Overall, Indigenous coverage at 24 months of age exceeded that at 12 months of age nationally and for all jurisdictions, but as receipt of varicella vaccine at 18 months is excluded from calculations, this represents delayed immunisation, with some contribution from immunisation incentives. The 'fully vaccinated' coverage estimates for vaccinations due by 60 months of age for Indigenous children exceeded 90% at 91% in 2012. Unlike in 2011, at 60 months of age, there was no dramatic variation in coverage between Indigenous and non-Indigenous children for individual jurisdictions. As previously documented, vaccines recommended for Indigenous children only, hepatitis A and pneumococcal vaccine, had suboptimal coverage at 60.1% and 73.1%, respectively, although there was a considerable improvement in coverage from 2011, 57.7% and 68.2% respectively. On-time receipt (before 49 months of age) of vaccines by Indigenous children at the 60-month milestone age improved substantially between 2011 (19%) and 2012 (38%) but the disparity in on-time vaccination between Indigenous and non-Indigenous children worsened at the 60-month age milestone from 2011 (from 1.8 to 5.4 percentage points) and remained the same for the 12 and 24-month age milestones. By late 2012, the percentage of children who received the 1st dose of DTPa vaccine dose at less than 8 weeks of age was greater than 50% in all but 1 jurisdiction and greater than 70% for New South Wales, the Australian Capital Territory and Tasmania. Further, by late 2012, the percentage of children who received the 4th dose of DTPa vaccine dose at less than 4 years of age was greater than 30% in 3 jurisdictions. The percentage of children whose parents officially objected to vaccination in Australia was 1.7% and this figure varied by jurisdiction. However, there is a further 2.1% of children whose parents don't officially object but whose children have no vaccines recorded on the ACIR. Coverage data for the 3rd dose of HPV from the national HPV register in the school catch up program was similar to 2011 at 71% but was substantially lower for the catch up program for females outside school (44%-69%), although this was an improvement from 2011.

  7. NSW Annual Immunisation Coverage Report, 2009.

    PubMed

    Hull, Brynley; Dey, Aditi; Mahajan, Deepika; Campbell-Lloyd, Sue; Menzies, Robert I; McIntyre, Peter B

    2010-01-01

    This is the first in a series of annual immunisation coverage reports that document trends in NSW for a range of standard measures derived from Australian Childhood Immunisation Register data, including overall coverage at standard age milestones and for individual vaccines. This report includes data up to and including 2009. Data from the Australian Childhood Immunisation Register, the NSW Health Survey and the NSW School Immunisation Program were used to calculate various measures of population coverage relating to childhood vaccines, adult influenza and pneumococcal vaccines and adolescent vaccination, respectively. Immunise Australia Program targets have been reached for children at 12 and 24 months of age but not for children at 5 years of age. Delayed receipt of vaccines is an issue for vaccines recommended for Aboriginal children. Pneumococcal vaccination in the elderly has been steadily rising, although it has remained lower than the influenza coverage estimates. For adolescents, there is better coverage for the first and second doses of human papillomavirus vaccine and the dose of dTpa than for varicella. This comprehensive analysis provides important baseline data for NSW against which future reports can be compared to monitor progress in improving immunisation coverage. Immunisation at the earliest appropriate age should be a public health goal for countries such as Australia where high levels of vaccine coverage at milestone ages have been achieved.

  8. The effects of intra-fraction organ motion on the delivery of intensity-modulated field with a multileaf collimator.

    PubMed

    Chui, Chen-Shou; Yorke, Ellen; Hong, Linda

    2003-07-01

    Intensity-modulated radiation therapy can be conveniently delivered with a multileaf collimator. With this method, the entire field is not delivered at once, but rather it is composed of many subfields defined by the leaf positions as a function of beam on time. At any given instant, only these subfields are delivered. During treatment, if the organ moves, part of the volume may move in or out of these subfields. Due to this interplay between organ motion and leaf motion the delivered dose may be different from what was planned. In this work, we present a method that calculates the effects of organ motion on delivered dose. The direction of organ motion may be parallel or perpendicular to the leaf motion, and the effect can be calculated for a single fraction or for multiple fractions. Three breast patients and four lung patients were included in this study,with the amplitude of the organ motion varying from +/- 3.5 mm to +/- 10 mm, and the period varying from 4 to 8 seconds. Calculations were made for these patients with and without organ motion, and results were examined in terms of isodose distribution and dose volume histograms. Each calculation was repeated ten times in order to estimate the statistical uncertainties. For selected patients, calculations were also made with conventional treatment technique. The effects of organ motion on conventional techniques were compared relative to that on IMRT techniques. For breast treatment, the effect of organ motion primarily broadened the penumbra at the posterior field edge. The dose in the rest of the treatment volume was not significantly affected. For lung treatment, the effect also broadened the penumbra and degraded the coverage of the planning target volume (PTV). However, the coverage of the clinical target volume (CTV) was not much affected, provided the PTV margin was adequate. The same effects were observed for both IMRT and conventional treatment techniques. For the IMRT technique, the standard deviations of ten samples of a 30-fraction calculation were very small for all patients, implying that over a typical treatment course of 30 fractions, the delivered dose was very close to the expected value. Hence, under typical clinical conditions, the effect of organ motion on delivered dose can be calculated without considering the interplay between the organ motion and the leaf motion. It can be calculated as the weighted average of the dose distribution without organ motion with the distribution of organ motion. Since the effects of organ motion on dose were comparable for both IMRT and conventional techniques, the PTV margin should remain the same for both techniques.

  9. Insurance coverage and prenatal care among low-income pregnant women: an assessment of states' adoption of the "Unborn Child" option in Medicaid and CHIP.

    PubMed

    Jarlenski, Marian P; Bennett, Wendy L; Barry, Colleen L; Bleich, Sara N

    2014-01-01

    The "Unborn Child" (UC) option provides state Medicaid/Children's Health Insurance Program (CHIP) programs with a new strategy to extend prenatal coverage to low-income women who would otherwise have difficulty enrolling in or would be ineligible for Medicaid. To examine the association of the UC option with the probability of enrollment in Medicaid/CHIP during pregnancy and probability of receiving adequate prenatal care. We use pooled cross-sectional data from the Pregnancy Risk Assessment Monitoring System from 32 states between 2004 and 2010 (n = 81,983). Multivariable regression is employed to examine the association of the UC option with Medicaid/CHIP enrollment during pregnancy among eligible women who were uninsured preconception (n = 45,082) and those who had insurance (but not Medicaid) preconception (n = 36,901). Multivariable regression is also employed to assess the association between the UC option and receipt of adequate prenatal care, measured by the Adequacy of Prenatal Care Utilization Index. Residing in a state with the UC option is associated with a greater probability of Medicaid enrollment during pregnancy relative to residing in a state without the policy both among women uninsured preconception (88% vs. 77%, P < 0.01) and among women insured (but not in Medicaid) preconception (40% vs. 31%, P < 0.01). Residing in a state with the UC option is not significantly associated with receiving adequate prenatal care, among both women with and without insurance preconception. The UC option provides states a key way to expand or simplify prenatal insurance coverage, but further policy efforts are needed to ensure that coverage improves access to high-quality prenatal care.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bosarge, Christina L., E-mail: cbosarge@umail.iu.edu; Ewing, Marvene M.; DesRosiers, Colleen M.

    To demonstrate the dosimetric advantages and disadvantages of standard anteroposterior-posteroanterior (S-AP/PA{sub AAA}), inverse-planned AP/PA (IP-AP/PA) and volumetry-modulated arc (VMAT) radiotherapies in the treatment of children undergoing whole-lung irradiation. Each technique was evaluated by means of target coverage and normal tissue sparing, including data regarding low doses. A historical approach with and without tissue heterogeneity corrections is also demonstrated. Computed tomography (CT) scans of 10 children scanned from the neck to the reproductive organs were used. For each scan, 6 plans were created: (1) S-AP/PA{sub AAA} using the anisotropic analytical algorithm (AAA), (2) IP-AP/PA, (3) VMAT, (4) S-AP/PA{sub NONE} without heterogeneitymore » corrections, (5) S-AP/PA{sub PB} using the Pencil-Beam algorithm and enforcing monitor units from technique 4, and (6) S-AP/PA{sub AAA[FM]} using AAA and forcing fixed monitor units. The first 3 plans compare modern methods and were evaluated based on target coverage and normal tissue sparing. Body maximum and lower body doses (50% and 30%) were also analyzed. Plans 4 to 6 provide a historic view on the progression of heterogeneity algorithms and elucidate what was actually delivered in the past. Averages of each comparison parameter were calculated for all techniques. The S-AP/PA{sub AAA} technique resulted in superior target coverage but had the highest maximum dose to every normal tissue structure. The IP-AP/PA technique provided the lowest dose to the esophagus, stomach, and lower body doses. VMAT excelled at body maximum dose and maximum doses to the heart, spine, and spleen, but resulted in the highest dose in the 30% body range. It was, however, superior to the S-AP/PA{sub AAA} approach in the 50% range. Each approach has strengths and weaknesses thus associated. Techniques may be selected on a case-by-case basis and by physician preference of target coverage vs normal tissue sparing.« less

  11. SU-F-T-81: Treating Nose Skin Using Energy and Intensity Modulated Electron Beams with Monte Carlo Based Dose Calculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jin, L; Fan, J; Eldib, A

    Purpose: Treating nose skin with an electron beam is of a substantial challenge due to uneven nose surfaces and tissue heterogeneity, and consequently could have a great uncertainty of dose accuracy on the target. This work explored the method using Monte Carlo (MC)-based energy and intensity modulated electron radiotherapy (MERT), which would be delivered with a photon MLC in a standard medical linac (Artiste). Methods: The traditional treatment on the nose skin involves the usage of a bolus, often with a single energy electron beam. This work avoided using the bolus, and utilized mixed energies of electron beams. An in-housemore » developed Monte Carlo (MC)-based dose calculation/optimization planning system was employed for treatment planning. Phase space data (6, 9, 12 and 15 MeV) were used as an input source for MC dose calculations for the linac. To reduce the scatter-caused penumbra, a short SSD (61 cm) was used. A clinical case of the nose skin, which was previously treated with a single 9 MeV electron beam, was replanned with the MERT method. The resultant dose distributions were compared with the plan previously clinically used. The dose volume histogram of the MERT plan is calculated to examine the coverage of the planning target volume (PTV) and critical structure doses. Results: The target coverage and conformality in the MERT plan are improved as compared to the conventional plan. The MERT can provide more sufficient target coverage and less normal tissue dose underneath the nose skin. Conclusion: Compared to the conventional treatment technique, using MERT for the nose skin treatment has shown the dosimetric advantages in the PTV coverage and conformality. In addition, this technique eliminates the necessity of the cutout and bolus, which makes the treatment more efficient and accurate.« less

  12. Policy statement—Professional liability insurance and medicolegal education for pediatric residents and fellows.

    PubMed

    Gonzalez, Jose Luis

    2011-09-01

    The American Academy of Pediatrics believes that pediatric residents and fellows should be fully informed of the scope and limitations of their professional liability insurance coverage while in training. The academy states that residents and fellows should be educated by their training institutions on matters relating to medical liability and the importance of maintaining adequate and continuous professional liability insurance coverage throughout their careers in medicine.

  13. SU-F-J-13: Choosing An IMRT Technique in the Treatment of Head and Neck Cancer with Daily Localization Uncertainties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, T; Wang, L; Galloway, T

    Purpose: Head and Neck cancer treatment with IMRT/VMAT has two choices: split-filed IMRT(SFI), in which the LAN is treated with a separate anterior field and the extended whole-field IMRT(WFI) in which LAN is included with the IMRT/VMAT field. This study shows that under the same dose limit criteria, choosing the technique becomes a critical issue if daily localization and immobilization altered the dose distribution. Methods: Nine common head-and-neck cancer cases were chosen to illustrate how the daily localization and immobilization uncertainties affect to choose between SFI and WFI. Both SFI and WFI at upper target coverage were generated with VMAT.more » For each case, the same planning criteria were applied to the target and critical structures; therefore, similar target coverage and dose falloff can be observed in both techniques. Thirty days of kV cone beam CT(CBCT) images on each case were also delineated with contralateral and ipsilateral target as well as larynx as critical structure. About 300 CBCT images with daily delivered doses were analyzed and compared in a form of dose-volume histograms. Results: While both plans for SFI and WFI with VMAT planning utilized and meet the criteria of D95>prescription dose and for not-involved larynx with mean dose <35Gy and V55<10%, the daily localization and immobilization has a great contribution to the resulted dose delivery. With WFI, the better daily contralateral and ipsilateral neck target coverage can reflect a simpler or shorter localization; however, a much superior avoidance (WFI: mean dose a 42.5Gy; SFI: mean dose a 18.9Gy) of the non-involved larynx from the SFI is preferred. Conclusion: Dosimetrically, SFI and WFI are equally well for head and Neck cancer treatment with VMAT technique; however, if considering the contribution of daily localization(CBCT) method uncertainties, SFI is better with sparing non-involved larynx and WFI has better target coverage.« less

  14. SU-C-202-05: Pilot Study of Online Treatment Evaluation and Adaptive Re-Planning for Laryngeal SBRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mao, W; Henry Ford Health System, Detroit, MI; Liu, C

    Purpose: We have instigated a phase I trial of 5-fraction stereotactic body radiotherapy (SBRT) for advanced-stage laryngeal cancer. We conducted this pilot dosimetric study to confirm the potential utility of online adaptive re-planning to preserve treatment quality. Methods: Ten cases of larynx cancer were evaluated. Baseline and daily SBRT treatment plans were generated per trial protocol. Daily volumetric images were acquired prior to every fraction of treatment. Reference simulation CT images were deformably registered to daily volumetric images using Eclipse. Planning contours were then deformably propagated to daily images. Reference SBRT plans were directly copied to calculate delivered dose distributionsmore » on deformed reference CT images. In-house software platform has been developed to calculate cumulative dose over a course of treatment in four steps: 1) deforming delivered dose grid to reference CT images using deformation information exported from Eclipse; 2) generating tetrahedrons using deformed dose grid as vertices; 3) resampling dose to a high resolution within every tetrahedron; 4) calculating dose-volume histograms. Our inhouse software was benchmarked with a commercial software, Mirada. Results: In all ten cases including 49 fractions of treatments, delivered daily doses were completely evaluated and treatment could be re-planned within 10 minutes. Prescription dose coverage of PTV was less than intended in 53% of fractions of treatment (mean: 94%, range: 84%–98%) while minimum coverage of CTV and GTV was 94% and 97%, respectively. Maximum bystander point dose limits to arytenoids, parotids, and spinal cord remained respected in all cases, although variances in carotid artery doses were observed in a minority of cases. Conclusion: Although GTV and CTV coverage is preserved by in-room 3D image guidance of larynx SBRT, PTV coverage can vary significantly from intended plans. Online adaptive treatment evaluation and re-planning is potentially necessary and our procedure is clinically applicable to fully preserve treatment quality. This project is supported by CPRIT Individual Investigator Research Award RP150386.« less

  15. Analysis of nodal coverage utilizing image guided radiation therapy for primary gynecologic tumor volumes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmed, Faisal; Loma Linda University Medical Center, Department of Radiation Oncology, Loma Linda, CA; Sarkar, Vikren

    Purpose: To evaluate radiation dose delivered to pelvic lymph nodes, if daily Image Guided Radiation Therapy (IGRT) was implemented with treatment shifts based on the primary site (primary clinical target volume [CTV]). Our secondary goal was to compare dosimetric coverage with patient outcomes. Materials and methods: A total of 10 female patients with gynecologic malignancies were evaluated retrospectively after completion of definitive intensity-modulated radiation therapy (IMRT) to their pelvic lymph nodes and primary tumor site. IGRT consisted of daily kilovoltage computed tomography (CT)-on-rails imaging fused with initial planning scans for position verification. The initial plan was created using Varian's Eclipsemore » treatment planning software. Patients were treated with a median radiation dose of 45 Gy (range: 37.5 to 50 Gy) to the primary volume and 45 Gy (range: 45 to 64.8 Gy) to nodal structures. One IGRT scan per week was randomly selected from each patient's treatment course and re-planned on the Eclipse treatment planning station. CTVs were recreated by fusion on the IGRT image series, and the patient's treatment plan was applied to the new image set to calculate delivered dose. We evaluated the minimum, maximum, and 95% dose coverage for primary and nodal structures. Reconstructed primary tumor volumes were recreated within 4.7% of initial planning volume (0.9% to 8.6%), and reconstructed nodal volumes were recreated to within 2.9% of initial planning volume (0.01% to 5.5%). Results: Dosimetric parameters averaged less than 10% (range: 1% to 9%) of the original planned dose (45 Gy) for primary and nodal volumes on all patients (n = 10). For all patients, ≥99.3% of the primary tumor volume received ≥ 95% the prescribed dose (V95%) and the average minimum dose was 96.1% of the prescribed dose. In evaluating nodal CTV coverage, ≥ 99.8% of the volume received ≥ 95% the prescribed dose and the average minimum dose was 93%. In evaluating individual IGRT sessions, we found that 6 patients had an estimated minimal nodal CTV dose less than 90% (range: 78 to 99%) of that planned. With a median follow-up of 42.5 months, 2 patients experienced systemic disease progression at an average of 19.6 months. One patient was found to have a local or regional failure with an average follow-up of 42 months. Conclusion: Using only 3 dimensional IGRT corrections in gynecological radiation allows excellent coverage of the primary target volume and good average nodal CTV coverage. If IGRT corrections are based on alignment to the primary tumor volume, and is only able to be corrected in 3 degrees, this can create situations in which nodal volumes may be under dosed. Utilizing multiple IGRT sessions appears to average out dose discrepancies over the course of treatment. The implication of underdosing in a single IGRT session needs further evaluation in future studies. Based on the concern of minimum dose to a nodal target volume, these findings may signal caution when using IGRT and IMRT in gynecological radiation patients. Possible techniques to overcome this situation may include averaging shifts between tumor and nodal volume, use of a treatment couch with 6° of freedom, deformable registration, or adaptive planning.« less

  16. Patient-specific dose estimation for pediatric abdomen-pelvis CT

    NASA Astrophysics Data System (ADS)

    Li, Xiang; Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Frush, Donald P.

    2009-02-01

    The purpose of this study is to develop a method for estimating patient-specific dose from abdomen-pelvis CT examinations and to investigate dose variation across patients in the same weight group. Our study consisted of seven pediatric patients in the same weight/protocol group, for whom full-body computer models were previously created based on the patients' CT data obtained for clinical indications. Organ and effective dose of these patients from an abdomen-pelvis scan protocol (LightSpeed VCT scanner, 120-kVp, 85-90 mA, 0.4-s gantry rotation period, 1.375-pitch, 40-mm beam collimation, and small body scan field-of-view) was calculated using a Monte Carlo program previously developed and validated for the same CT system. The seven patients had effective dose of 2.4-2.8 mSv, corresponding to normalized effective dose of 6.6-8.3 mSv/100mAs (coefficient of variation: 7.6%). Dose variations across the patients were small for large organs in the scan coverage (mean: 6.6%; range: 4.9%-9.2%), larger for small organs in the scan coverage (mean: 10.3%; range: 1.4%-15.6%), and the largest for organs partially or completely outside the scan coverage (mean: 14.8%; range: 5.7%-27.7%). Normalized effective dose correlated strongly with body weight (correlation coefficient: r = -0.94). Normalized dose to the kidney and the adrenal gland correlated strongly with mid-liver equivalent diameter (kidney: r = -0.97; adrenal glands: r = -0.98). Normalized dose to the small intestine correlated strongly with mid-intestine equivalent diameter (r = -0.97). These strong correlations suggest that patient-specific dose may be estimated for any other child in the same size group who undergoes the abdomen-pelvis scan.

  17. Equity of the premium of the Ghanaian national health insurance scheme and the implications for achieving universal coverage

    PubMed Central

    2013-01-01

    The Ghanaian National Health Insurance Scheme (NHIS) was introduced to provide access to adequate health care regardless of ability to pay. By law the NHIS is mandatory but because the informal sector has to make premium payment before they are enrolled, the authorities are unable to enforce mandatory nature of the scheme. The ultimate goal of the Scheme then is to provide all residents with access to adequate health care at affordable cost. In other words, the Scheme intends to achieve universal coverage. An important factor for the achievement of universal coverage is that revenue collection be equitable. The purpose of this study is to examine the vertical and horizontal equity of the premium collection of the Scheme. The Kakwani index method as well as graphical analysis was used to study the vertical equity. Horizontal inequity was measured through the effect of the premium on redistribution of ability to pay of members. The extent to which the premium could cause catastrophic expenditure was also examined. The results showed that revenue collection was both vertically and horizontally inequitable. The horizontal inequity had a greater effect on redistribution of ability to pay than vertical inequity. The computation of catastrophic expenditure showed that a small minority of the poor were likely to incur catastrophic expenditure from paying the premium a situation that could impede the achievement of universal coverage. The study provides recommendations to improve the inequitable system of premium payment to help achieve universal coverage. PMID:23294982

  18. Cooperative Purchasing of Insurance and Risk Management Services.

    ERIC Educational Resources Information Center

    Maedke, Thomas F.

    1988-01-01

    Self Insurance (pooling) offers premium dollar savings, improved coverage, and adequate limits to school districts, governmental entities, and private-sector groups. Outlines a common and safe pool structure. (MLF)

  19. Neurovascular bundle–sparing radiotherapy for prostate cancer using MRI-CT registration: A dosimetric feasibility study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cassidy, R.J., E-mail: richardjcassidy@emory.edu; Yang, X.; Liu, T.

    Purpose: Sexual dysfunction after radiotherapy for prostate cancer remains an important late adverse toxicity. The neurovascular bundles (NVB) that lie posterolaterally to the prostate are typically spared during prostatectomy, but in traditional radiotherapy planning they are not contoured as an organ-at-risk with dose constraints. Our goal was to determine the dosimetric feasibility of “NVB-sparing” prostate radiotherapy while still delivering adequate dose to the prostate. Methods: Twenty-five consecutive patients with prostate cancer (with no extraprostatic disease on pelvic magnetic resonance imaging [MRI]) who that were treated with external beam radiotherapy, with the same primary planning target volume margins, to a dosemore » of 79.2 Gy were evaluated. Pelvic MRI and simulation computed tomography scans were registered using dedicated software to allow for bilateral NVB target delineation on T2-weighted MRI. A volumetric modulated arc therapy plan was generated using the NVB bilaterally with 2 mm margin as an organ to spare and compared to the patient’s previously delivered plan. Dose-volume histogram endpoints for NVB, rectum, bladder, and planning target volume 79.2 were compared between the 2 plans using a 2-tailed paired t-test. Results: The V70 for the NVB was significantly lower on the NVB-sparing plan (p <0.01), while rectum and bladder endpoints were similar. Target V100% was similar but V{sub 105%} was higher for the NVB-sparing plans (p <0.01). Conclusions: “NVB-sparing” radiotherapy is dosimetrically feasible using CT-MRI registration, and for volumetric modulated arc therapy technology — target coverage is acceptable without increased dose to other normal structures, but with higher target dose inhomogeneity. The clinical impact of “NVB-sparing” radiotherapy is currently under study at our institution.« less

  20. Dosimetrically Triggered Adaptive Intensity Modulated Radiation Therapy for Cervical Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lim, Karen; Stewart, James; Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario

    2014-09-01

    Purpose: The widespread use of intensity modulated radiation therapy (IMRT) for cervical cancer has been limited by internal target and normal tissue motion. Such motion increases the risk of underdosing the target, especially as planning margins are reduced in an effort to reduce toxicity. This study explored 2 adaptive strategies to mitigate this risk and proposes a new, automated method that minimizes replanning workload. Methods and Materials: Thirty patients with cervical cancer participated in a prospective clinical study and underwent pretreatment and weekly magnetic resonance (MR) scans over a 5-week course of daily external beam radiation therapy. Target volumes andmore » organs at risk (OARs) were contoured on each of the scans. Deformable image registration was used to model the accumulated dose (the real dose delivered to the target and OARs) for 2 adaptive replanning scenarios that assumed a very small PTV margin of only 3 mm to account for setup and internal interfractional motion: (1) a preprogrammed, anatomy-driven midtreatment replan (A-IMRT); and (2) a dosimetry-triggered replan driven by target dose accumulation over time (D-IMRT). Results: Across all 30 patients, clinically relevant target dose thresholds failed for 8 patients (27%) if 3-mm margins were used without replanning. A-IMRT failed in only 3 patients and also yielded an additional small reduction in OAR doses at the cost of 30 replans. D-IMRT assured adequate target coverage in all patients, with only 23 replans in 16 patients. Conclusions: A novel, dosimetry-triggered adaptive IMRT strategy for patients with cervical cancer can minimize the risk of target underdosing in the setting of very small margins and substantial interfractional motion while minimizing programmatic workload and cost.« less

  1. Whole-brain hippocampal sparing radiation therapy: Volume-modulated arc therapy vs intensity-modulated radiation therapy case study.

    PubMed

    Lee, Katrina; Lenards, Nishele; Holson, Janice

    2016-01-01

    The hippocampus is responsible for memory and cognitive function. An ongoing phase II clinical trial suggests that sparing dose to the hippocampus during whole-brain radiation therapy can help preserve a patient׳s neurocognitive function. Progressive research and advancements in treatment techniques have made treatment planning more sophisticated but beneficial for patients undergoing treatment. The aim of this study is to evaluate and compare hippocampal sparing whole-brain (HS-WB) radiation therapy treatment planning techniques using volume-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT). We randomly selected 3 patients to compare different treatment techniques that could be used for reducing dose to the hippocampal region. We created 2 treatment plans, a VMAT and an IMRT, from each patient׳s data set and planned on the Eclipse 11.0 treatment planning system (TPS). A total of 6 plans (3 IMRT and 3 VMAT) were created and evaluated for this case study. The physician contoured the hippocampus as per the Radiation Therapy Oncology Group (RTOG) 0933 protocol atlas. The organs at risk (OR) were contoured and evaluated for the plan comparison, which included the spinal cord, optic chiasm, the right and left eyes, lenses, and optic nerves. Both treatment plans produced adequate coverage on the planning target volume (PTV) while significantly reducing dose to the hippocampal region. The VMAT treatment plans produced a more homogenous dose distribution throughout the PTV while decreasing the maximum point dose to the target. However, both treatment techniques demonstrated hippocampal sparing when irradiating the whole brain. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  2. Uptake of oral rotavirus vaccine and timeliness of routine immunization in Brazil’s National Immunization Program

    PubMed Central

    Flannery, Brendan; Samad, Samia; de Moraes, José Cássio; Tate, Jacqueline E.; Danovaro-Holliday, M. Carolina; de Oliveira, Lúcia Helena; Rainey, Jeanette J.

    2015-01-01

    Introduction In March, 2006, oral rotavirus vaccine was added to Brazil’s infant immunization schedule with recommended upper age limits for initiating (by age 14 weeks) and completing (by age 24 weeks) the two-dose series to minimize age-specific risk of intussusception following rotavirus vaccination. Several years after introduction, estimated coverage with rotavirus vaccine (83%) was lower compared to coverage for other recommended childhood immunizations (≥94%). Methods We analyzed data from Brazil’s national immunization program on uptake of oral rotavirus vaccine by geographic region and compared administrative coverage estimates for first and second doses of oral rotavirus vaccine (Rota1 and Rota2) with first and second doses of diphtheria-tetanus-pertussis-Haemophilus influenzae type b vaccine (DTP-Hib1 and DTP-Hib2). For 27 Brazilian cities, we compared differences between estimated rotavirus and DTP-Hib coverage in 2010 with delayed receipt of DTP-Hib vaccine among a cohort of children surveyed before rotavirus introduction. Results In 2010, infant vaccination coverage was 99.0% for DTP-Hib1 versus 95.2% for Rota1 (3.8% difference), and 98.4% for DTP-Hib2 versus 83.0% for Rota2 (15.4% difference), with substantial regional variation. Differences between DTP-Hib and rotavirus vaccination coverage in Brazilian cities correlated with delay in DTP-Hib vaccination among children surveyed. Age restrictions for initiating and completing the rotavirus vaccination series likely contributed to lower coverage with rotavirus vaccine in Brazil. Conclusion To maximize benefits of rotavirus vaccination, strategies are needed to improve timeliness of routine immunizations; monitoring rotavirus vaccine uptake and intussusception risk is needed to guide further recommendations for rotavirus vaccination. PMID:23313652

  3. [Potential coverage and real coverage of ambulatory health care services in the state of Mexico. The case of 3 marginal communities in Atenco and Chalco].

    PubMed

    Nájera-Aguilar, P; Infante-Castañeda, C

    1990-01-01

    Less than a third of the non-insured population studied through a sample in the State of Mexico was covered by the Institute of Health of the State of México. This low coverage was observed in spite the fact that health services were available within 2 kilometer radius. 33 per cent of the non-insured preferred to utilize other services within their own community, and 24 per cent of them traveled to bigger localities to receive care. These results suggest that to attain adequate coverage, utilization patterns should be investigated so that health services can meet the needs of the target population.

  4. Adequate margins for random setup uncertainties in head-and-neck IMRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Astreinidou, Eleftheria; Bel, Arjan; Raaijmakers, Cornelis P.J.

    2005-03-01

    Purpose: To investigate the effect of random setup uncertainties on the highly conformal dose distributions produced by intensity-modulated radiotherapy (IMRT) for clinical head-and-neck cancer patients and to determine adequate margins to account for those uncertainties. Methods and materials: We have implemented in our clinical treatment planning system the possibility of simulating normally distributed patient setup displacements, translations, and rotations. The planning CT data of 8 patients with Stage T1-T3N0M0 oropharyngeal cancer were used. The clinical target volumes of the primary tumor (CTV{sub primary}) and of the lymph nodes (CTV{sub elective}) were expanded by 0.0, 1.5, 3.0, and 5.0 mm inmore » all directions, creating the planning target volumes (PTVs). We performed IMRT dose calculation using our class solution for each PTV margin, resulting in the conventional static plans. Then, the system recalculated the plan for each positioning displacement derived from a normal distribution with {sigma} = 2 mm and {sigma} = 4 mm (standard deviation) for translational deviations and {sigma} = 1 deg for rotational deviations. The dose distributions of the 30 fractions were summed, resulting in the actual plan. The CTV dose coverage of the actual plans was compared with that of the static plans. Results: Random translational deviations of {sigma} = 2 mm and rotational deviations of {sigma} = 1 deg did not affect the CTV{sub primary} volume receiving 95% of the prescribed dose (V{sub 95}) regardless of the PTV margin used. A V{sub 95} reduction of 3% and 1% for a 0.0-mm and 1.5-mm PTV margin, respectively, was observed for {sigma} = 4 mm. The V{sub 95} of the CTV{sub elective} contralateral was approximately 1% and 5% lower than that of the static plan for {sigma} = 2 mm and {sigma} = 4 mm, respectively, and for PTV margins < 5.0 mm. An additional reduction of 1% was observed when rotational deviations were included. The same effect was observed for the CTV{sub elective} ipsilateral but with smaller dose differences than those for the contralateral side. The effect of the random uncertainties on the mean dose to the parotid glands was not significant. The maximal dose to the spinal cord increased by a maximum of 3 Gy. Conclusions: The margins to account for random setup uncertainties, in our clinical IMRT solution, should be 1.5 mm and 3.0 mm in the case of {sigma} = 2 mm and {sigma} = 4 mm, respectively, for the CTV{sub primary}. Larger margins (5.0 mm), however, should be applied to the CTV{sub elective}, if the goal of treatment is a V{sub 95} value of at least 99%.« less

  5. State of equity: childhood immunization in the World Health Organization African Region.

    PubMed

    Casey, Rebecca Mary; Hampton, Lee McCalla; Anya, Blanche-Philomene Melanga; Gacic-Dobo, Marta; Diallo, Mamadou Saliou; Wallace, Aaron Stuart

    2017-01-01

    In 2010, the Global Vaccine Action Plan called on all countries to reach and sustain 90% national coverage and 80% coverage in all districts for the third dose of diphtheria-tetanus-pertussis vaccine (DTP3) by 2015 and for all vaccines in national immunization schedules by 2020. The aims of this study are to analyze recent trends in national vaccination coverage in the World Health Organization African Region andto assess how these trends differ by country income category. We compared national vaccination coverage estimates for DTP3 and the first dose of measles-containing vaccine (MCV) obtained from the World Health Organization (WHO)/United Nations Children's Fund (UNICEF) joint estimates of national immunization coverage for all African Region countries. Using United Nations (UN) population estimates of surviving infants and country income category for the corresponding year, we calculated population-weighted average vaccination coverage by country income category (i.e., low, lower middle, and upper middle-income) for the years 2000, 2005, 2010 and 2015. DTP3 coverage in the African Region increased from 52% in 2000 to 76% in 2015,and MCV1 coverage increased from 53% to 74% during the same period, but with considerable differences among countries. Thirty-six African Region countries were low income in 2000 with an average DTP3 coverage of 50% while 26 were low income in 2015 with an average coverage of 80%. Five countries were lower middle-income in 2000 with an average DTP3 coverage of 84% while 12 were lower middle-income in 2015 with an average coverage of 69%. Five countries were upper middle-income in 2000 with an average DTP3 coverage of 73% and eight were upper middle-income in 2015 with an average coverage of 76%. Disparities in vaccination coverage by country persist in the African Region, with countries that were lower middle-income having the lowest coverage on average in 2015. Monitoring and addressing these disparities is essential for meeting global immunization targets.

  6. Evaluating Different Dimensions of Programme Effectiveness for Private Medicine Retailer Malaria Control Interventions in Kenya

    PubMed Central

    Abuya, Timothy O.; Fegan, Greg; Amin, Abdinasir A.; Akhwale, Willis S.; Noor, Abdisalan M.; Snow, Robert W.; Marsh, Vicki

    2010-01-01

    Background Private medicine retailers (PMRs) are key partners in the home management of fevers in many settings. Current evidence on effectiveness for PMR interventions at scale is limited. This study presents evaluation findings of two different programs implemented at moderate scale targeting PMRs for malaria control in the Kisii and Kwale districts of Kenya. Key components of this evaluation were measurement of program performance, including coverage, PMR knowledge, practices, and utilization based on spatial analysis. Methodology/Principal Findings The study utilized mixed quantitative methods including retail audits and surrogate client surveys based on post-intervention cross-sectional surveys in intervention and control areas and mapping of intervention outlets. There was a large and significant impact on PMR knowledge and practices of the program in Kisii, with 60.5% of trained PMRs selling amodiaquine medicines in adequate doses compared to 2.8% of untrained ones (OR; 53.5: 95% CI 6.7, 428.3), a program coverage of 69.7% targeted outlets, and a potential utilization of about 30,000 children under five. The evaluation in Kwale also indicates a significant impact with 18.8% and 2.3% intervention and control PMRs selling amodiaquine with correct advice, respectively (OR; 9.4: 95% CI 1.1, 83.7), a program coverage of 25.3% targeted outlets, and a potential utilization of about 48,000 children under five. A provisional benchmark of 7.5 km was a reasonable threshold distance for households to access PMR services. Conclusions/Significance This evaluation show that PMR interventions operationalized in the district level settings are likely to impact PMR knowledge and practices and lead to increased coverage of appropriate treatment to target populations. There is value of evaluating different dimensions of public health programs, including quality, spatial access, and implementation practice. This approach strengthens the potential contribution of pragmatic study designs to evaluating public health programs in the real world. PMID:20126620

  7. Development of Automated Moment Tensor Software at the Prototype International Data Center

    DTIC Science & Technology

    2000-09-01

    Berkeley Digital Seismic Network stations in the 100 to 500 km distance range. With sufficient azimuthal coverage this method is found to perform...the solution reported by NIED (http://argent.geo.bosai.go.jp/ freesia /event/hypo/joho.html). The normal mechanism obtained by the three-component...Digital Seismic Network stations. These stations provide more than 100 degrees of azimuthal coverage, which is an adequate sampling of the focal

  8. HPV Vaccination Coverage of Male Adolescents in the United States

    PubMed Central

    Lu, Peng-jun; Yankey, David; Jeyarajah, Jenny; O’Halloran, Alissa; Elam-Evans, Laurie D.; Smith, Philip J.; Stokley, Shannon; Singleton, James A.; Dunne, Eileen F.

    2018-01-01

    Background In 2011, the Advisory Committee for Immunization Practices (ACIP) recommended routine use HPV vaccine for male adolescents. Methods We used the 2013 National Immunization Survey-Teen (NIS-Teen) data to assess HPV vaccine uptake (≥1 dose) and series completion (≥3 doses). Multivariable logistic regression analysis and a predictive marginal model were conducted to identify independent predictors of vaccination among adolescent males aged 13–17 years. Results HPV vaccination coverage with ≥1 dose was 34.6% while series completion (≥3 doses) was 13.9%. Coverage was significantly higher among non-Hispanic blacks and Hispanics compared with non-Hispanic white males. Multivariable logistic regression showed that characteristics independently associated with a higher likelihood of HPV vaccination (≥1 dose) included: being non-Hispanic black race or Hispanic ethnicity, having mothers who were widowed, divorced, or separated, having 1–3 physician contacts in the past 12 months, a well-child visit at age 11–12 years, having one or two vaccination providers, living in urban or suburban areas, and receiving vaccinations from more than one type of facility (p<0.05). Having mothers with some college or college education, having a higher family income to poverty ratio, living in South or Midwest, and receiving vaccinations from all STD/school/teen clinics or other facilities were independently associated with a lower likelihood of HPV vaccination (p<0.05). Conclusions Following recommendations for routine HPV vaccination among male adolescents, uptake in 2013 was low in males. Increased efforts are needed to improve vaccination coverage, especially for those who are least likely to be vaccinated. PMID:26504124

  9. 78 FR 36174 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-17

    ... investigation regarding an accident that occurs in connection with a contract; and to determine whether a contractor performing a service or construction contract in Spain has adequate insurance coverage. Affected...

  10. A practical approach to determine dose metrics for nanomaterials.

    PubMed

    Delmaar, Christiaan J E; Peijnenburg, Willie J G M; Oomen, Agnes G; Chen, Jingwen; de Jong, Wim H; Sips, Adriënne J A M; Wang, Zhuang; Park, Margriet V D Z

    2015-05-01

    Traditionally, administered mass is used to describe doses of conventional chemical substances in toxicity studies. For deriving toxic doses of nanomaterials, mass and chemical composition alone may not adequately describe the dose, because particles with the same chemical composition can have completely different toxic mass doses depending on properties such as particle size. Other dose metrics such as particle number, volume, or surface area have been suggested, but consensus is lacking. The discussion regarding the most adequate dose metric for nanomaterials clearly needs a systematic, unbiased approach to determine the most appropriate dose metric for nanomaterials. In the present study, the authors propose such an approach and apply it to results from in vitro and in vivo experiments with silver and silica nanomaterials. The proposed approach is shown to provide a convenient tool to systematically investigate and interpret dose metrics of nanomaterials. Recommendations for study designs aimed at investigating dose metrics are provided. © 2015 SETAC.

  11. Neighborhood-targeted and case-triggered use of a single dose of oral cholera vaccine in an urban setting: Feasibility and vaccine coverage.

    PubMed

    Parker, Lucy A; Rumunu, John; Jamet, Christine; Kenyi, Yona; Lino, Richard Laku; Wamala, Joseph F; Mpairwe, Allan M; Muller, Vincent; Llosa, Augusto E; Uzzeni, Florent; Luquero, Francisco J; Ciglenecki, Iza; Azman, Andrew S

    2017-06-01

    In June 2015, a cholera outbreak was declared in Juba, South Sudan. In addition to standard outbreak control measures, oral cholera vaccine (OCV) was proposed. As sufficient doses to cover the at-risk population were unavailable, a campaign using half the standard dosing regimen (one-dose) targeted high-risk neighborhoods and groups including neighbors of suspected cases. Here we report the operational details of this first public health use of a single-dose regimen of OCV and illustrate the feasibility of conducting highly targeted vaccination campaigns in an urban area. Neighborhoods of the city were prioritized for vaccination based on cumulative attack rates, active transmission and local knowledge of known cholera risk factors. OCV was offered to all persons older than 12 months at 20 fixed sites and to select groups, including neighbors of cholera cases after the main campaign ('case-triggered' interventions), through mobile teams. Vaccination coverage was estimated by multi-stage surveys using spatial sampling techniques. 162,377 individuals received a single-dose of OCV in the targeted neighborhoods. In these neighborhoods vaccine coverage was 68.8% (95% Confidence Interval (CI), 64.0-73.7) and was highest among children ages 5-14 years (90.0%, 95% CI 85.7-94.3), with adult men being less likely to be vaccinated than adult women (Relative Risk 0.81, 95% CI: 0.68-0.96). In the case-triggered interventions, each lasting 1-2 days, coverage varied (range: 30-87%) with an average of 51.0% (95% CI 41.7-60.3). Vaccine supply constraints and the complex realities where cholera outbreaks occur may warrant the use of flexible alternative vaccination strategies, including highly-targeted vaccination campaigns and single-dose regimens. We showed that such campaigns are feasible. Additional work is needed to understand how and when to use different strategies to best protect populations against epidemic cholera.

  12. Progress Toward Measles Elimination - African Region, 2013-2016.

    PubMed

    Masresha, Balcha G; Dixon, Meredith G; Kriss, Jennifer L; Katsande, Reggis; Shibeshi, Messeret E; Luce, Richard; Fall, Amadou; Dosseh, Annick R G A; Byabamazima, Charles R; Dabbagh, Alya J; Goodson, James L; Mihigo, Richard

    2017-05-05

    In 2011, the 46 World Health Organization (WHO) African Region (AFR) member states established a goal of measles elimination* by 2020, by achieving 1) ≥95% coverage of their target populations with the first dose of measles-containing vaccine (MCV1) at national and district levels; 2) ≥95% coverage with measles-containing vaccine (MCV) per district during supplemental immunization activities (SIAs); and 3) confirmed measles incidence of <1 case per 1 million population in all countries (1). Two key surveillance performance indicator targets include 1) investigating ≥2 cases of nonmeasles febrile rash illness per 100,000 population annually, and 2) obtaining a blood specimen from ≥1 suspected measles case in ≥80% of districts annually (2). This report updates the previous report (3) and describes progress toward measles elimination in AFR during 2013-2016. Estimated regional MCV1 coverage † increased from 71% in 2013 to 74% in 2015. § Seven (15%) countries achieved ≥95% MCV1 coverage in 2015. ¶ The number of countries providing a routine second MCV dose (MCV2) increased from 11 (24%) in 2013 to 23 (49%) in 2015. Forty-one (79%) of 52 SIAs** during 2013-2016 reported ≥95% coverage. Both surveillance targets were met in 19 (40%) countries in 2016. Confirmed measles incidence in AFR decreased from 76.3 per 1 million population to 27.9 during 2013-2016. To eliminate measles by 2020, AFR countries and partners need to 1) achieve ≥95% 2-dose MCV coverage through improved immunization services, including second dose (MCV2) introduction; 2) improve SIA quality by preparing 12-15 months in advance, and using readiness, intra-SIA, and post-SIA assessment tools; 3) fully implement elimination-standard surveillance †† ; 4) conduct annual district-level risk assessments; and 5) establish national committees and a regional commission for the verification of measles elimination.

  13. Cluster Survey Evaluation of a Measles Vaccination Campaign in Jharkhand, India, 2012

    PubMed Central

    Scobie, Heather M.; Ray, Arindam; Routray, Satyabrata; Bose, Anindya; Bahl, Sunil; Sosler, Stephen; Wannemuehler, Kathleen; Kumar, Rakesh; Haldar, Pradeep; Anand, Abhijeet

    2015-01-01

    Introduction India was the last country in the world to implement a two-dose strategy for measles-containing vaccine (MCV) in 2010. As part of measles second-dose introduction, phased measles vaccination campaigns were conducted during 2010–2013, targeting 131 million children 9 months to <10 years of age. We performed a post-campaign coverage survey to estimate measles vaccination coverage in Jharkhand state. Methods A multi-stage cluster survey was conducted 2 months after the phase 2 measles campaign occurred in 19 of 24 districts of Jharkhand during November 2011–March 2012. Vaccination status of children 9 months to <10 years of age was documented based on vaccination card or mother’s recall. Coverage estimates and 95% confidence intervals (95% CI) for 1,018 children were calculated using survey methods. Results In the Jharkhand phase 2 campaign, MCV coverage among children aged 9 months to <10 years was 61.0% (95% CI: 54.4–67.7%). Significant differences in coverage were observed between rural (65.0%; 95% CI: 56.8–73.2%) and urban areas (45.6%; 95% CI: 37.3–53.9%). Campaign awareness among mothers was low (51.5%), and the most commonly reported reason for non-vaccination was being unaware of the campaign (69.4%). At the end of the campaign, 53.7% (95% CI: 46.5–60.9%) of children 12 months to <10 years of age received ≥2 MCV doses, while a large proportion of children remained under-vaccinated (34.0%, 95% CI: 28.0–40.0%) or unvaccinated (12.3%, 95% CI: 9.3–16.2%). Conclusions Implementation of the national measles campaign was a significant achievement towards measles elimination in India. In Jharkhand, campaign performance was below the target coverage of ≥90% set by the Government of India, and challenges in disseminating campaign messages were identified. Efforts towards increasing two-dose MCV coverage are needed to achieve the recently adopted measles elimination goal in India and the South-East Asia region. PMID:26010084

  14. TU-H-CAMPUS-JeP3-05: Adaptive Determination of Needle Sequence HDR Prostate Brachytherapy with Divergent Needle-By-Needle Delivery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borot de Battisti, M; Maenhout, M; Lagendijk, J J W

    Purpose: To develop a new method which adaptively determines the optimal needle insertion sequence for HDR prostate brachytherapy involving divergent needle-by-needle dose delivery by e.g. a robotic device. A needle insertion sequence is calculated at the beginning of the intervention and updated after each needle insertion with feedback on needle positioning errors. Methods: Needle positioning errors and anatomy changes may occur during HDR brachytherapy which can lead to errors in the delivered dose. A novel strategy was developed to calculate and update the needle sequence and the dose plan after each needle insertion with feedback on needle positioning errors. Themore » dose plan optimization was performed by numerical simulations. The proposed needle sequence determination optimizes the final dose distribution based on the dose coverage impact of each needle. This impact is predicted stochastically by needle insertion simulations. HDR procedures were simulated with varying number of needle insertions (4 to 12) using 11 patient MR data-sets with PTV, prostate, urethra, bladder and rectum delineated. Needle positioning errors were modeled by random normally distributed angulation errors (standard deviation of 3 mm at the needle’s tip). The final dose parameters were compared in the situations where the needle with the largest vs. the smallest dose coverage impact was selected at each insertion. Results: Over all scenarios, the percentage of clinically acceptable final dose distribution improved when the needle selected had the largest dose coverage impact (91%) compared to the smallest (88%). The differences were larger for few (4 to 6) needle insertions (maximum difference scenario: 79% vs. 60%). The computation time of the needle sequence optimization was below 60s. Conclusion: A new adaptive needle sequence determination for HDR prostate brachytherapy was developed. Coupled to adaptive planning, the selection of the needle with the largest dose coverage impact increases chances of reaching the clinical constraints. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are fulltime employees of Philips Medical Systems Nederland B.V.« less

  15. Bowel sparing in pediatric cranio-spinal radiotherapy: a comparison of combined electron and photon and helical TomoTherapy techniques to a standard photon method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harron, Elizabeth, E-mail: elizabeth.harron@nuh.nhs.uk; Lewis, Joanne

    2012-07-01

    The aim of this study was to compare the dose to organs at risk (OARs) from different craniospinal radiotherapy treatment approaches available at the Northern Centre for Cancer Care (NCCC), with a particular emphasis on sparing the bowel. Method: Treatment plans were produced for a pediatric medulloblastoma patient with inflammatory bowel disease using 3D conformal 6-MV photons (3DCP), combined 3D 6-MV photons and 18-MeV electrons (3DPE), and helical photon TomoTherapy (HT). The 3DPE plan was a modification of the standard 3DCP technique, using electrons to treat the spine inferior to the level of the diaphragm. The plans were compared inmore » terms of the dose-volume data to OARs and the nontumor integral dose. Results: The 3DPE plan was found to give the lowest dose to the bowel and the lowest nontumor integral dose of the 3 techniques. However, the coverage of the spine planning target volume (PTV) was least homogeneous using this technique, with only 74.6% of the PTV covered by 95% of the prescribed dose. HT was able to achieve the best coverage of the PTVs (99.0% of the whole-brain PTV and 93.1% of the spine PTV received 95% of the prescribed dose), but delivered a significantly higher integral dose. HT was able to spare the heart, thyroid, and eyes better than the linac-based techniques, but other OARs received a higher dose. Conclusions: Use of electrons was the best method for reducing the dose to the bowel and the integral dose, at the expense of compromised spine PTV coverage. For some patients, HT may be a viable method of improving dose homogeneity and reducing selected OAR doses.« less

  16. Progress in global measles control, 2000-2010.

    PubMed

    2012-02-03

    In 1980, before widespread global use of measles vaccine, an estimated 2.6 million measles deaths occurred worldwide. In 2001, to accelerate the reduction in measles cases achieved by vaccination, the World Health Organization (WHO) and the United Nations Children's Fund (UNICEF) developed a strategy to deliver 2 doses of measles-containing vaccine (MCV) to all children through routine services and supplementary immunization activities (SIAs) and improved disease surveillance. After implementation of this strategy, the estimated number of annual measles deaths worldwide decreased from 733,000 in 2000 to 164,000 in 2008. In 2010, the World Health Assembly endorsed the following measles objectives for 2015: 1) raise routine coverage with the first dose of MCV (MCV1) for children aged 1 year to ≥90% nationally and ≥80% in every district or equivalent administrative unit, 2) reduce and maintain annual measles incidence at <5 cases per million, and 3) reduce measles mortality by ≥95% from the 2000 estimate. During 2000-2010, global MCV1 coverage increased from 72% to 85% with approximately 1 billion children vaccinated during measles SIAs. Reported measles cases decreased from 2000 to 2008, remained stable in 2009, and increased in 2010. By the end of 2010, 40% of countries still had not met the incidence target of <5 cases per million. Key challenges must be overcome to meet the 2015 objectives, including 1) declining political and financial commitments to measles control, 2) failure to reach uniform high coverage with 2 doses of MCV through routine services or SIAs, and 3) inadequate monitoring subnationally of coverage with the first and second dose of MCV to guide interventions to increase coverage.

  17. 78 FR 15935 - Information Collection Requirement; Defense Federal Acquisition Regulation Supplement (DFARS...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-13

    ... construction contract in Spain has adequate insurance coverage. Affected Public: Businesses or other for profit... construction contract in Spain. Kortnee Stewart, Editor, Defense Acquisition Regulations System. [FR Doc. 2013...

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matney, Jason; Park, Peter C.; The University of Texas Graduate School of Biomedical Sciences, Houston, Texas

    Purpose: To quantify and compare the effects of respiratory motion on paired passively scattered proton therapy (PSPT) and intensity modulated photon therapy (IMRT) plans; and to establish the relationship between the magnitude of tumor motion and the respiratory-induced dose difference for both modalities. Methods and Materials: In a randomized clinical trial comparing PSPT and IMRT, radiation therapy plans have been designed according to common planning protocols. Four-dimensional (4D) dose was computed for PSPT and IMRT plans for a patient cohort with respiratory motion ranging from 3 to 17 mm. Image registration and dose accumulation were performed using grayscale-based deformable imagemore » registration algorithms. The dose–volume histogram (DVH) differences (4D-3D [3D = 3-dimensional]) were compared for PSPT and IMRT. Changes in 4D-3D dose were correlated to the magnitude of tumor respiratory motion. Results: The average 4D-3D dose to 95% of the internal target volume was close to zero, with 19 of 20 patients within 1% of prescribed dose for both modalities. The mean 4D-3D between the 2 modalities was not statistically significant (P<.05) for all dose–volume histogram indices (mean ± SD) except the lung V5 (PSPT: +1.1% ± 0.9%; IMRT: +0.4% ± 1.2%) and maximum cord dose (PSPT: +1.5 ± 2.9 Gy; IMRT: 0.0 ± 0.2 Gy). Changes in 4D-3D dose were correlated to tumor motion for only 2 indices: dose to 95% planning target volume, and heterogeneity index. Conclusions: With our current margin formalisms, target coverage was maintained in the presence of respiratory motion up to 17 mm for both PSPT and IMRT. Only 2 of 11 4D-3D indices (lung V5 and spinal cord maximum) were statistically distinguishable between PSPT and IMRT, contrary to the notion that proton therapy will be more susceptible to respiratory motion. Because of the lack of strong correlations with 4D-3D dose differences in PSPT and IMRT, the extent of tumor motion was not an adequate predictor of potential dosimetric error caused by breathing motion.« less

  19. The adequate rocuronium dose required for complete block of the adductor muscles of the thigh.

    PubMed

    Fujimoto, M; Kawano, K; Yamamoto, T

    2018-03-01

    Rocuronium can prevent the obturator jerk during transurethral resection of bladder tumors. We investigated the adequate rocuronium dose required for complete block of the thigh adductor muscles, and its correlation with individual responses of the adductor pollicis muscle to rocuronium. Eleven patients scheduled for transurethral resection of bladder tumors under general anesthesia were investigated. After general anesthesia induction, neuromuscular monitoring of the adductor pollicis muscle and ultrasonography-guided stimulation of the obturator nerve was commenced. Rocuronium, 0.15 mg/kg, was repeatedly administered intravenously. The adequate rocuronium dose required for complete block of the thigh muscles, defined as the cumulative dose of rocuronium administered until that time, and its correlation with the first twitch response of the adductor pollicis muscle on train-of-four stimulation after initial rocuronium administration was analyzed. The rocuronium dose found adequate for complete block of the thigh muscles was 0.30 mg/kg in seven patients and 0.45 mg/kg in the remaining four patients, which did not correlate with the first twitch response. At the time of complete block of the thigh muscles, the neuromuscular blockade level of the adductor pollicis muscle varied greatly, although the level was never more profound than a post-tetanic count of 1. Although the response of the adductor pollicis muscle to rocuronium cannot be used to determine the adequate rocuronium dose required for complete block of the thigh muscles, intense blockade, with maintenance of post-tetanic count at ≤ 1 in the adductor pollicis muscle is essential to prevent the obturator jerk. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  20. Reconstruction of posterior neck and skull with vertical trapezius musculocutaneous flap

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mathes, S.J.; Stevenson, T.R.

    1988-10-01

    The vertical trapezius musculocutaneous flap has been successfully utilized for reconstruction in 13 patients with complex posterior skull and neck defects. This flap based on its vascular pedicle, the descending branch of the transverse cervical artery, provides well-vascularized tissue for coverage of defects related to chronic osteomyelitis, tumor extirpation, osteoradionecrosis, and dehisced cervical laminectomy wounds. Emphasis on flap design, including the location of the skin island, allows adequate wound coverage, direct donor site closure, and muscle function preservation. With its large size and wide arc of rotation, the vertical trapezius musculocutaneous flap provides reliable coverage for posterior trunk, cervical, andmore » skull defects.« less

  1. An assessment of mumps vaccine effectiveness by dose during an outbreak in Canada

    PubMed Central

    Deeks, Shelley L.; Lim, Gillian H.; Simpson, Mary Anne; Gagné, Louise; Gubbay, Jonathan; Kristjanson, Erik; Fung, Cecilia; Crowcroft, Natasha S.

    2011-01-01

    Background This investigation was done to assess vaccine effectiveness of one and two doses of the measles, mumps and rubella (MMR) vaccine during an outbreak of mumps in Ontario. The level of coverage required to reach herd immunity and interrupt community transmission of mumps was also estimated. Methods Information on confirmed cases of mumps was retrieved from Ontario’s integrated Public Health Information System. Cases that occurred between Sept. 1, 2009, and June 10, 2010, were included. Selected health units supplied coverage data from the Ontario Immunization Record Information System. Vaccine effectiveness by dose was calculated using the screening method. The basic reproductive number (R0) represents the average number of new infections per case in a fully susceptile population, and R0 values of between 4 and 10 were considered for varying levels of vaccine effectiveness. Results A total of 134 confirmed cases of mumps were identified. Information on receipt of MMR vaccine was available for 114 (85.1%) cases, of whom 63 (55.3%) reported having received only one dose of vaccine; 32 (28.1%) reported having received two doses. Vaccine effectiveness of one dose of the MMR vaccine ranged from 49.2% to 81.6%, whereas vaccine effectiveness of two doses ranged from 66.3% to 88.0%. If we assume vaccine effectiveness of 85% for two doses of the vaccine, vaccine coverage of 88.2% and 98.0% would be needed to interrupt community transmission of mumps if the corresponding reproductive values were four and six. Interpretation Our estimates of vaccine effectiveness of one and two doses of mumps-containing vaccine were consistent with the estimates that have been reported in other outbreaks. Outbreaks occurring in Ontario and elsewhere serve as a warning against complacency over vaccination programs. PMID:21576295

  2. An assessment of mumps vaccine effectiveness by dose during an outbreak in Canada.

    PubMed

    Deeks, Shelley L; Lim, Gillian H; Simpson, Mary Anne; Gagné, Louise; Gubbay, Jonathan; Kristjanson, Erik; Fung, Cecilia; Crowcroft, Natasha S

    2011-06-14

    This investigation was done to assess vaccine effectiveness of one and two doses of the measles, mumps and rubella (MMR) vaccine during an outbreak of mumps in Ontario. The level of coverage required to reach herd immunity and interrupt community transmission of mumps was also estimated. Information on confirmed cases of mumps was retrieved from Ontario's integrated Public Health Information System. Cases that occurred between Sept. 1, 2009, and June 10, 2010, were included. Selected health units supplied coverage data from the Ontario Immunization Record Information System. Vaccine effectiveness by dose was calculated using the screening method. The basic reproductive number (R(0)) represents the average number of new infections per case in a fully susceptible population, and R(0) values of between 4 and 10 were considered for varying levels of vaccine effectiveness. A total of 134 confirmed cases of mumps were identified. Information on receipt of MMR vaccine was available for 114 (85.1%) cases, of whom 63 (55.3%) reported having received only one dose of vaccine; 32 (28.1%) reported having received two doses. Vaccine effectiveness of one dose of the MMR vaccine ranged from 49.2% to 81.6%, whereas vaccine effectiveness of two doses ranged from 66.3% to 88.0%. If we assume vaccine effectiveness of 85% for two doses of the vaccine, vaccine coverage of 88.2% and 98.0% would be needed to interrupt community transmission of mumps if the corresponding reproductive values were four and six. Our estimates of vaccine effectiveness of one and two doses of mumps-containing vaccine were consistent with the estimates that have been reported in other outbreaks. Outbreaks occurring in Ontario and elsewhere serve as a warning against complacency over vaccination programs.

  3. Impact of Adverse Events Following Immunization in Viet Nam in 2013 on chronic hepatitis B infection.

    PubMed

    Li, Xi; Wiesen, Eric; Diorditsa, Sergey; Toda, Kohei; Duong, Thi Hong; Nguyen, Lien Huong; Nguyen, Van Cuong; Nguyen, Tran Hien

    2016-02-03

    Adverse Events Following Immunization in Viet Nam in 2013 led to substantial reductions in hepatitis B vaccination coverage (both the birth dose and the three-dose series). In order to estimate the impact of the reduction in vaccination coverage on hepatitis B transmission and future mortality, a widely-used mathematical model was applied to the data from Viet Nam. Using the model, we estimated the number of chronic infections and deaths that are expected to occur in the birth cohort in 2013 and the number of excessive infections and deaths attributable to the drop in immunization coverage in 2013. An excess of 90,137 chronic infections and 17,456 future deaths were estimated to occur in the 2013 birth cohort due to the drop in vaccination coverage. This analysis highlights the importance of maintaining high vaccination coverage and swiftly responding to reported Adverse Events Following Immunization in order to regain consumer confidence in the hepatitis B vaccine. Copyright © 2015 World Health Organization; licensee Elsevier. Published by Elsevier Ltd.. All rights reserved.

  4. Marked increase in measles vaccination coverage among young adults in Switzerland: a campaign or cohort effect?

    PubMed

    Altpeter, Ekkehardt; Wymann, Monica N; Richard, Jean-Luc; Mäusezahl-Feuz, Mirjam

    2018-06-01

    To evaluate the impact of the Swiss measles elimination strategy-including a mass media campaign-on vaccination coverage and awareness among young adults aged 20-29 years. Comparison of the results of two cross-sectional population surveys in 2012 and 2015. Documented vaccination coverage increased from 77 to 88% for two doses of measles vaccine. Major determinants of complete vaccination were survey year, birth cohort, sex and the absence of prior measles disease. If birth cohort and prior history of measles disease are included as factors in a multivariate model, the difference between 2012 and 2015 vanishes. The marked increase in complete measles vaccination coverage is due to a cohort effect, owing to the introduction of the second dose of vaccine in 1996. Most of the vaccinations were administered before the national strategy was implemented and vaccination catch-ups did not increase during the campaign in young adults. Nevertheless, this study provides evidence of an improvement in the awareness of measles and measles vaccination in young adults, which may result in an impact on measles vaccination coverage in the near future.

  5. Applications of tissue heterogeneity corrections and biologically effective dose volume histograms in assessing the doses for accelerated partial breast irradiation using an electronic brachytherapy source.

    PubMed

    Shi, Chengyu; Guo, Bingqi; Cheng, Chih-Yao; Eng, Tony; Papanikolaou, Nikos

    2010-09-21

    A low-energy electronic brachytherapy source (EBS), the model S700 Axxent x-ray device developed by Xoft Inc., has been used in high dose rate (HDR) intracavitary accelerated partial breast irradiation (APBI) as an alternative to an Ir-192 source. The prescription dose and delivery schema of the electronic brachytherapy APBI plan are the same as the Ir-192 plan. However, due to its lower mean energy than the Ir-192 source, an EBS plan has dosimetric and biological features different from an Ir-192 source plan. Current brachytherapy treatment planning methods may have large errors in treatment outcome prediction for an EBS plan. Two main factors contribute to the errors: the dosimetric influence of tissue heterogeneities and the enhancement of relative biological effectiveness (RBE) of electronic brachytherapy. This study quantified the effects of these two factors and revisited the plan quality of electronic brachytherapy APBI. The influence of tissue heterogeneities is studied by a Monte Carlo method and heterogeneous 'virtual patient' phantoms created from CT images and structure contours; the effect of RBE enhancement in the treatment outcome was estimated by biologically effective dose (BED) distribution. Ten electronic brachytherapy APBI cases were studied. The results showed that, for electronic brachytherapy cases, tissue heterogeneities and patient boundary effect decreased dose to the target and skin but increased dose to the bones. On average, the target dose coverage PTV V(100) reduced from 95.0% in water phantoms (planned) to only 66.7% in virtual patient phantoms (actual). The actual maximum dose to the ribs is 3.3 times higher than the planned dose; the actual mean dose to the ipsilateral breast and maximum dose to the skin were reduced by 22% and 17%, respectively. Combining the effect of tissue heterogeneities and RBE enhancement, BED coverage of the target was 89.9% in virtual patient phantoms with RBE enhancement (actual BED) as compared to 95.2% in water phantoms without RBE enhancement (planned BED). About 10% increase in the source output is required to raise BED PTV V(100) to 95%. As a conclusion, the composite effect of dose reduction in the target due to heterogeneities and RBE enhancement results in a net effect of 5.3% target BED coverage loss for electronic brachytherapy. Therefore, it is suggested that about 10% increase in the source output may be necessary to achieve sufficient target coverage higher than 95%.

  6. Applications of tissue heterogeneity corrections and biologically effective dose volume histograms in assessing the doses for accelerated partial breast irradiation using an electronic brachytherapy source

    NASA Astrophysics Data System (ADS)

    Shi, Chengyu; Guo, Bingqi; Cheng, Chih-Yao; Eng, Tony; Papanikolaou, Nikos

    2010-09-01

    A low-energy electronic brachytherapy source (EBS), the model S700 Axxent™ x-ray device developed by Xoft Inc., has been used in high dose rate (HDR) intracavitary accelerated partial breast irradiation (APBI) as an alternative to an Ir-192 source. The prescription dose and delivery schema of the electronic brachytherapy APBI plan are the same as the Ir-192 plan. However, due to its lower mean energy than the Ir-192 source, an EBS plan has dosimetric and biological features different from an Ir-192 source plan. Current brachytherapy treatment planning methods may have large errors in treatment outcome prediction for an EBS plan. Two main factors contribute to the errors: the dosimetric influence of tissue heterogeneities and the enhancement of relative biological effectiveness (RBE) of electronic brachytherapy. This study quantified the effects of these two factors and revisited the plan quality of electronic brachytherapy APBI. The influence of tissue heterogeneities is studied by a Monte Carlo method and heterogeneous 'virtual patient' phantoms created from CT images and structure contours; the effect of RBE enhancement in the treatment outcome was estimated by biologically effective dose (BED) distribution. Ten electronic brachytherapy APBI cases were studied. The results showed that, for electronic brachytherapy cases, tissue heterogeneities and patient boundary effect decreased dose to the target and skin but increased dose to the bones. On average, the target dose coverage PTV V100 reduced from 95.0% in water phantoms (planned) to only 66.7% in virtual patient phantoms (actual). The actual maximum dose to the ribs is 3.3 times higher than the planned dose; the actual mean dose to the ipsilateral breast and maximum dose to the skin were reduced by 22% and 17%, respectively. Combining the effect of tissue heterogeneities and RBE enhancement, BED coverage of the target was 89.9% in virtual patient phantoms with RBE enhancement (actual BED) as compared to 95.2% in water phantoms without RBE enhancement (planned BED). About 10% increase in the source output is required to raise BED PTV V100 to 95%. As a conclusion, the composite effect of dose reduction in the target due to heterogeneities and RBE enhancement results in a net effect of 5.3% target BED coverage loss for electronic brachytherapy. Therefore, it is suggested that about 10% increase in the source output may be necessary to achieve sufficient target coverage higher than 95%.

  7. Parent Preferences and Perceptions of Milliliters and Teaspoons: Role of Health Literacy and Experience.

    PubMed

    Torres, Alejandro; Parker, Ruth M; Sanders, Lee M; Wolf, Michael S; Bailey, Stacy Cooper; Patel, Deesha A; Jimenez, Jessica J; Kim, Kwang-Youn A; Dreyer, Benard P; Mendelsohn, Alan L; Yin, H Shonna

    A recent American Academy of Pediatrics policy statement recommends milliliter-exclusive dosing for pediatric liquid medications. Little is known about parent preferences regarding units, perceptions about moving to milliliters only, and the role of health literacy and prior milliliter-dosing experience. Cross-sectional analysis of data collected as part of a randomized controlled study in 3 urban pediatric clinics (SAFE Rx for Kids study). English- and Spanish-speaking parents (n = 493) of children aged ≤8 years were randomized to 1 of 4 study arms and given labels and dosing tools which varied in label instruction format (text plus pictogram, text only) and units (milliliter only ["mL"], milliliter/teaspoon ["mL"/"tsp"]). Outcomes included teaspoon preference in dosing instructions and perceived difficulty with milliliter-only dosing. The predictor variable was health literacy (Newest Vital Sign; low [0-1], marginal [2-3], adequate [4-6]). The mediating variable was prior milliliter-dosing experience. Over two-thirds of parents had low or marginal health literacy. The majority (>70%) preferred to use milliliters, perceived milliliter-only dosing to be easy, and had prior milliliter-dosing experience; 11.5% had a teaspoon preference, 18.1% perceived milliliter-only dosing will be difficult, and 17.7% had no prior milliliter-dosing experience. Parents with lower health literacy had a higher odds of having a teaspoon preference (low vs adequate: adjusted odds ratio [AOR] = 2.9 [95% confidence interval [CI] 1.3-6.2]), and greater odds of perceiving difficulty with milliliter-only dosing (low vs adequate: AOR = 13.9 [95% CI 4.8-40.6], marginal vs adequate: AOR = 7.1 [95% CI 2.5-20.4]). Lack of experience with milliliter dosing partially mediated the impact of health literacy. Most parents were comfortable with milliliter-only dosing. Parents with low health literacy were more likely to perceive milliliter-only dosing to be difficult; educational efforts will need to target this group to ensure safe medication use. Copyright © 2017 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  8. Bilateral implant reconstruction does not affect the quality of postmastectomy radiation therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, Alice Y., E-mail: hoa1234@mskcc.org; Patel, Nisha; Ohri, Nisha

    To determine if the presence of bilateral implants, in addition to other anatomic and treatment-related variables, affects coverage of the target volume and dose to the heart and lung in patients receiving postmastectomy radiation therapy (PMRT). A total of 197 consecutive women with breast cancer underwent mastectomy and immediate tissue expander (TE) placement, with or without exchange for a permanent implant (PI) before radiation therapy at our center. PMRT was delivered with 2 tangential beams + supraclavicular lymph node field (50 Gy). Patients were grouped by implant number: 51% unilateral (100) and 49% bilateral (97). The planning target volume (PTV)more » (defined as implant + chest wall + nodes), heart, and ipsilateral lung were contoured and the following parameters were abstracted from dose-volume histogram (DVH) data: PTV D{sub 95%} > 98%, Lung V{sub 20}Gy > 30%, and Heart V{sub 25}Gy > 5%. Univariate (UVA) and multivariate analyses (MVA) were performed to determine the association of variables with these parameters. The 2 groups were well balanced for implant type and volume, internal mammary node (IMN) treatment, and laterality. In the entire cohort, 90% had PTV D{sub 95%} > 98%, indicating excellent coverage of the chest wall. Of the patients, 27% had high lung doses (V{sub 20}Gy > 30%) and 16% had high heart doses (V{sub 25}Gy > 5%). No significant factors were associated with suboptimal PTV coverage. On MVA, IMN treatment was found to be highly associated with high lung and heart doses (both p < 0.0001), but implant number was not (p = 0.54). In patients with bilateral implants, IMN treatment was the only predictor of dose to the contralateral implant (p = 0.001). In conclusion, bilateral implants do not compromise coverage of the target volume or increase lung and heart dose in patients receiving PMRT. The most important predictor of high lung and heart doses in patients with implant-based reconstruction, whether unilateral or bilateral, is treatment of the IMNs. Refinement of radiation techniques in reconstructed patients who require comprehensive nodal irradiation is warranted.« less

  9. Selective robust optimization: A new intensity-modulated proton therapy optimization strategy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Yupeng; Niemela, Perttu; Siljamaki, Sami

    2015-08-15

    Purpose: To develop a new robust optimization strategy for intensity-modulated proton therapy as an important step in translating robust proton treatment planning from research to clinical applications. Methods: In selective robust optimization, a worst-case-based robust optimization algorithm is extended, and terms of the objective function are selectively computed from either the worst-case dose or the nominal dose. Two lung cancer cases and one head and neck cancer case were used to demonstrate the practical significance of the proposed robust planning strategy. The lung cancer cases had minimal tumor motion less than 5 mm, and, for the demonstration of the methodology,more » are assumed to be static. Results: Selective robust optimization achieved robust clinical target volume (CTV) coverage and at the same time increased nominal planning target volume coverage to 95.8%, compared to the 84.6% coverage achieved with CTV-based robust optimization in one of the lung cases. In the other lung case, the maximum dose in selective robust optimization was lowered from a dose of 131.3% in the CTV-based robust optimization to 113.6%. Selective robust optimization provided robust CTV coverage in the head and neck case, and at the same time improved controls over isodose distribution so that clinical requirements may be readily met. Conclusions: Selective robust optimization may provide the flexibility and capability necessary for meeting various clinical requirements in addition to achieving the required plan robustness in practical proton treatment planning settings.« less

  10. Restricted Field IMRT Dramatically Enhances IMRT Planning for Mesothelioma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allen, Aaron M.; Schofield, Deborah; Hacker, Fred

    2007-12-01

    Purpose: To improve the target coverage and normal tissue sparing of intensity-modulated radiotherapy (IMRT) for mesothelioma after extrapleural pneumonectomy. Methods and Materials: Thirteen plans from patients previously treated with IMRT for mesothelioma were replanned using a restricted field technique. This technique was novel in two ways. It limited the entrance beams to 200{sup o} around the target and three to four beams per case had their field apertures restricted down to the level of the heart or liver to further limit the contralateral lung dose. New constraints were added that included a mean lung dose of <9.5 Gy and volumemore » receiving {>=}5 Gy of <55%. Results: In all cases, the planning target volume coverage was excellent, with an average of 97% coverage of the planning target volume by the target dose. No change was seen in the target coverage with the new technique. The heart, kidneys, and esophagus were all kept under tolerance in all cases. The average mean lung dose, volume receiving {>=}20 Gy, and volume receiving {>=}5 Gy with the new technique was 6.6 Gy, 3.0%, and 50.8%, respectively, compared with 13.8 Gy, 15%, and 90% with the previous technique (p < 0.0001 for all three comparisons). The maximal value for any case in the cohort was 8.0 Gy, 7.3%, and 57.5% for the mean lung dose, volume receiving {>=}20 Gy, and volume receiving {>=}5 Gy, respectively. Conclusion: Restricted field IMRT provides an improved method to deliver IMRT to a complex target after extrapleural pneumonectomy. An upcoming Phase I trial will provide validation of these results.« less

  11. Parental knowledge of paediatric vaccination

    PubMed Central

    Borràs, Eva; Domínguez, Àngela; Fuentes, Miriam; Batalla, Joan; Cardeñosa, Neus; Plasencia, Antoni

    2009-01-01

    Background Although routine vaccination is a major tool in the primary prevention of some infectious diseases, there is some reluctance in a proportion of the population. Negative parental perceptions of vaccination are an important barrier to paediatric vaccination. The aim of this study was to investigate parental knowledge of paediatric vaccines and vaccination in Catalonia. Methods A retrospective, cross-sectional study was carried out in children aged < 3 years recruited by random sampling from municipal districts of all health regions of Catalonia. The total sample was 630 children. Parents completed a standard questionnaire for each child, which included vaccination coverage and knowledge about vaccination. The level of knowledge of vaccination was scored according to parental answers. Results An association was observed between greater vaccination coverage of the 4:4:4:3:1 schedule (defined as: 4 DTPa/w doses, 4 Hib doses, 4 OPV doses, 3 MenC doses and 1 MMR dose) and maternal age >30 years (OR: 2.30; 95% CI: 1.20–4.43) and with a knowledge of vaccination score greater than the mean (OR: 0.45; 95% CI: 0.28–0.72). The score increased with maternal educational level and in parents of vaccinated children. A total of 20.47% of parents stated that vaccines could have undesirable consequences for their children. Of these, 23.26% had no specific information and 17.83% stated that vaccines can cause adverse reactions and the same percentage stated that vaccines cause allergies and asthma. Conclusion Higher vaccination coverage is associated with older maternal age and greater knowledge of vaccination. Vaccination coverage could be raised by improving information on vaccines and vaccination. PMID:19473498

  12. Predicting and comparing long-term measles antibody profiles of different immunization policies.

    PubMed

    Lee, M S; Nokes, D J

    2001-01-01

    Measles outbreaks are infrequent and localized in areas with high coverage of measles vaccine. The need is to assess long-term effectiveness of coverage. Since 1991, no measles epidemic affecting the whole island has occurred in Taiwan, China. Epidemiological models are developed to predict the long-term measles antibody profiles and compare the merits of different immunization policies on the island. The current measles immunization policy in Taiwan, China, is 1 dose of measles vaccine at 9 months of age and 1 dose of measles, mumps and rubella (MMR) vaccine at 15 months of age, plus a 'mop-up' of MMR-unvaccinated schoolchildren at 6 years of age. Refinements involve a change to a two-dose strategy. Five scenarios based on different vaccination strategies are compared. The models are analysed using Microsoft Excel. First, making the assumption that measles vaccine-induced immunity will not wane, the predicted measles IgG seroprevalences in preschool children range from 81% (lower bound) to 94% (upper bound) and in schoolchildren reach 97-98% in all strategy scenarios. Results are dependent on the association of vaccine coverage between the first and second dose of vaccine. Second, if it is assumed that vaccine-induced antibody titres decay, the long-term measles seroprevalence will depend on the initial titres post vaccination, decay rates of antibody titres and cut-off of seropositivity. If MMR coverage at 12 months of age can reach > 90%, it would be worth changing the current policy to 2 doses at 12 months and 6 years of age to induce higher antibody titres. These epidemiological models could be applied wherever a similar stage of measles elimination has been reached.

  13. Overview of Global, Regional, and National Routine Vaccination Coverage Trends and Growth Patterns From 1980 to 2009: Implications for Vaccine-Preventable Disease Eradication and Elimination Initiatives

    PubMed Central

    Wallace, Aaron S.; Ryman, Tove K.; Dietz, Vance

    2015-01-01

    Background Review of the historical growth in annual vaccination coverage across countries and regions can better inform decision makers’ development of future goals and strategies to improve routine vaccination services. Methods Using the World Health Organization (WHO) and the United Nations Children's Fund estimates of annual national third dose of diphtheria-tetanus-pertussis–containing vaccine (DTP3) and third dose of polio vaccine (POL3) coverage for 1980–2009, we calculated the mean absolute annual rate of change in national DTP3 coverage among all countries (globally) and among countries within each WHO region, as well as the number of years taken by each region to reach specific regional coverage levels. Last, we assessed differences in mean absolute annual rate of change in DTP3 coverage, stratified by baseline level of DTP3 coverage. Results During the 1980s, global DTP3 coverage increased a mean of 5.3 percentage points/year. Annual rate of change decreased to 0.5 percentage points/year in the 1990s and then increased to 0.9 percentage points/year during the 2000s. Mean annual rate of change in coverage across all countries was highest (9.2 percentage points) when national coverage levels were 26%–30% and lowest (−0.9 percentage points) when national coverage levels were 96%–100%. Regional differences existed as both WHO South-East Asia Region and WHO African Region countries experienced mean negative DTP3 coverage growth at lower coverage levels (81%–85%) than other regions. The regions that have achieved 95% DTP3 coverage (Americas, Western Pacific, and European) took 25–29 years to reach that level from a level of 50% DTP3 coverage. POL3 coverage change trends were similar to described DTP3 coverage change trends. Conclusions Mean national coverage growth patterns across all regions are nonlinear as coverage levels increase. Saturation points of mean 0 percentage-point growth in annual coverage varies by region and require further investigation. The achievement of >90% routine coverage is observed to take decades, which has implications for disease eradication and elimination initiatives. PMID:25316875

  14. Treatment of acute bacterial rhinosinusitis caused by antimicrobial-resistant Streptococcus pneumoniae.

    PubMed

    Anon, Jack B

    2004-08-02

    Acute bacterial rhinosinusitis (ABRS) is a secondary bacterial infection of the nose and paranasal sinuses, usually preceded by a viral upper respiratory infection or allergy, with symptoms that have not improved after 10 days or that have worsened after 5 to 7 days. Streptococcus pneumoniae and Haemophilus influenzae are the most common causes of ABRS in adults. Increasing rates of antimicrobial resistance among S. pneumoniae and beta-lactamase production among H. influenzae are formidable challenges to the successful treatment of infections caused by these organisms. To this end, various formulations of amoxicillin-clavulanate have been developed, the most recent of which is pharmacokinetically enhanced and provides a total daily dose of 4,000 mg of amoxicillin and 250 mg of clavulanate. This formulation has been shown to be safe and effective in the treatment of infections caused by penicillin-resistant S. pneumoniae (minimum inhibitory concentration 2 microg/mL); the clavulanate component provides adequate coverage of beta-lactamase-producing pathogens.

  15. Maternal Tetanus Toxoid Vaccination and Neonatal Mortality in Rural North India

    PubMed Central

    Singh, Abhishek; Pallikadavath, Saseendran; Ogollah, Reuben; Stones, William

    2012-01-01

    Objectives Preventable neonatal mortality due to tetanus infection remains common. We aimed to examine antenatal vaccination impact in a context of continuing high neonatal mortality in rural northern India. Methods and Findings Using the third round of the Indian National Family Health Survey (NFHS) 2005–06, mortality of most recent singleton births was analysed in discrete-time logistic model with maternal tetanus vaccination, together with antenatal care utilisation and supplementation with iron and folic acid. 59% of mothers reported receiving antenatal care, 48% reported receiving iron and folic acid supplementation and 68% reported receiving two or more doses of tetanus toxoid (TT) vaccination. The odds of all-cause neonatal death were reduced following one or more antenatal dose of TT with odds ratios (OR) of 0.46 (95% CI 0.26 to 0.78) after one dose and 0.45 (95% CI 0.31 to 0.66) after two or more doses. Reported utilisation of antenatal care and iron-folic acid supplementation did not influence neonatal mortality. In the statistical model, 16% (95% CI 5% to 27%) of neonatal deaths could be attributed to a lack of at least two doses of TT vaccination during pregnancy, representing an estimated 78,632 neonatal deaths in absolute terms. Conclusions Substantial gains in newborn survival could be achieved in rural North India through increased coverage of antenatal TT vaccination. The apparent substantial protective effect of a single antenatal dose of TT requires further study. It may reflect greater population vaccination coverage and indicates that health programming should prioritise universal antenatal coverage with at least one dose. PMID:23152814

  16. Maternal tetanus toxoid vaccination and neonatal mortality in rural north India.

    PubMed

    Singh, Abhishek; Pallikadavath, Saseendran; Ogollah, Reuben; Stones, William

    2012-01-01

    Preventable neonatal mortality due to tetanus infection remains common. We aimed to examine antenatal vaccination impact in a context of continuing high neonatal mortality in rural northern India. Using the third round of the Indian National Family Health Survey (NFHS) 2005-06, mortality of most recent singleton births was analysed in discrete-time logistic model with maternal tetanus vaccination, together with antenatal care utilisation and supplementation with iron and folic acid. 59% of mothers reported receiving antenatal care, 48% reported receiving iron and folic acid supplementation and 68% reported receiving two or more doses of tetanus toxoid (TT) vaccination. The odds of all-cause neonatal death were reduced following one or more antenatal dose of TT with odds ratios (OR) of 0.46 (95% CI 0.26 to 0.78) after one dose and 0.45 (95% CI 0.31 to 0.66) after two or more doses. Reported utilisation of antenatal care and iron-folic acid supplementation did not influence neonatal mortality. In the statistical model, 16% (95% CI 5% to 27%) of neonatal deaths could be attributed to a lack of at least two doses of TT vaccination during pregnancy, representing an estimated 78,632 neonatal deaths in absolute terms. Substantial gains in newborn survival could be achieved in rural North India through increased coverage of antenatal TT vaccination. The apparent substantial protective effect of a single antenatal dose of TT requires further study. It may reflect greater population vaccination coverage and indicates that health programming should prioritise universal antenatal coverage with at least one dose.

  17. Comparative evaluation of two-dimensional radiography and three dimensional computed tomography based dose-volume parameters for high-dose-rate intracavitary brachytherapy of cervical cancer: a prospective study.

    PubMed

    Madan, Renu; Pathy, Sushmita; Subramani, Vellaiyan; Sharma, Seema; Mohanti, Bidhu Kalyan; Chander, Subhash; Thulkar, Sanjay; Kumar, Lalit; Dadhwal, Vatsla

    2014-01-01

    Dosimetric comparison of two dimensional (2D) radiography and three-dimensional computed tomography (3D-CT) based dose distributions with high-dose-rate (HDR) intracavitry radiotherapy (ICRT) for carcinoma cervix, in terms of target coverage and doses to bladder and rectum. Sixty four sessions of HDR ICRT were performed in 22 patients. External beam radiotherapy to pelvis at a dose of 50 Gray in 27 fractions followed by HDR ICRT, 21 Grays to point A in 3 sessions, one week apart was planned . All patients underwent 2D-orthogonal and 3D-CT simulation for each session. Treatment plans were generated using 2D-orthogonal images and dose prescription was made at point A. 3D plans were generated using 3D-CT images after delineating target volume and organs at risk. Comparative evaluation of 2D and 3D treatment planning was made for each session in terms of target coverage (dose received by 90%, 95% and 100% of the target volume: D90, D95 and D100 respectively) and doses to bladder and rectum: ICRU-38 bladder and rectum point dose in 2D planning and dose to 0.1cc, 1cc, 2cc, 5cc, and 10cc of bladder and rectum in 3D planning. Mean doses received by 100% and 90% of the target volume were 4.24 ± 0.63 and 4.9 ± 0.56 Gy respectively. Doses received by 0.1cc, 1cc and 2cc volume of bladder were 2.88 ± 0.72, 2.5 ± 0.65 and 2.2 ± 0.57 times more than the ICRU bladder reference point. Similarly, doses received by 0.1cc, 1cc and 2cc of rectum were 1.80 ± 0.5, 1.48 ± 0.41 and 1.35 ± 0.37 times higher than ICRU rectal reference point. Dosimetric comparative evaluation of 2D and 3D CT based treatment planning for the same brachytherapy session demonstrates underestimation of OAR doses and overestimation of target coverage in 2D treatment planning.

  18. State of equity: childhood immunization in the World Health Organization African Region

    PubMed Central

    Casey, Rebecca Mary; Hampton, Lee McCalla; Anya, Blanche-philomene Melanga; Gacic-Dobo, Marta; Diallo, Mamadou Saliou; Wallace, Aaron Stuart

    2017-01-01

    Introduction In 2010, the Global Vaccine Action Plan called on all countries to reach and sustain 90% national coverage and 80% coverage in all districts for the third dose of diphtheria-tetanus-pertussis vaccine (DTP3) by 2015 and for all vaccines in national immunization schedules by 2020. The aims of this study are to analyze recent trends in national vaccination coverage in the World Health Organization African Region andto assess how these trends differ by country income category. Methods We compared national vaccination coverage estimates for DTP3 and the first dose of measles-containing vaccine (MCV) obtained from the World Health Organization (WHO)/United Nations Children’s Fund (UNICEF) joint estimates of national immunization coverage for all African Region countries. Using United Nations (UN) population estimates of surviving infants and country income category for the corresponding year, we calculated population-weighted average vaccination coverage by country income category (i.e., low, lower middle, and upper middle-income) for the years 2000, 2005, 2010 and 2015. Results DTP3 coverage in the African Region increased from 52% in 2000 to 76% in 2015,and MCV1 coverage increased from 53% to 74% during the same period, but with considerable differences among countries. Thirty-six African Region countries were low income in 2000 with an average DTP3 coverage of 50% while 26 were low income in 2015 with an average coverage of 80%. Five countries were lower middle-income in 2000 with an average DTP3 coverage of 84% while 12 were lower middle-income in 2015 with an average coverage of 69%. Five countries were upper middle-income in 2000 with an average DTP3 coverage of 73% and eight were upper middle-income in 2015 with an average coverage of 76%. Conclusion Disparities in vaccination coverage by country persist in the African Region, with countries that were lower middle-income having the lowest coverage on average in 2015. Monitoring and addressing these disparities is essential for meeting global immunization targets. PMID:29296140

  19. Immunisation coverage of adults: a vaccination counselling campaign in the pharmacies in Switzerland.

    PubMed

    Valeri, Fabio; Hatz, Christoph; Jordan, Dominique; Leuthold, Claudine; Czock, Astrid; Lang, Phung

    2014-01-01

    To assess vaccination coverage for adults living in Switzerland. Through a media campaign, the general population was invited during 1 month to bring their vaccination certificates to the pharmacies to have their immunisation status evaluated with the software viavac©, and to complete a questionnaire. A total of 496 pharmacies in Switzerland participated in the campaign, of which 284 (57%) submitted valid vaccination information. From a total of 3,634 participants in the campaign, there were 3,291 valid cases (participants born ≤ 1992) and 1,011 questionnaires completed. Vaccination coverage for the participants was 45.9% and 34.6% for five and six doses of diphtheria, 56.4% and 44.0% for tetanus and 66.3% and 48.0% for polio, respectively. Coverage estimates for one and two doses of measles vaccine were 76.5% and 49.4%, respectively, for the birth cohort 1967-1992 and 4.0% and 0.8%, respectively, for the cohort ≤ 1966. There was a significant difference in coverage for most vaccinations between the two aforementioned birth cohorts. A plot of the measles vaccine coverage over time shows that the increase in coverage correlated with policy changes in the Swiss Immunisation Schedule. Despite selection bias and low participation, this study indicates that vaccination coverage for the basic recommended immunisations in the adult population in Switzerland is suboptimal. More efforts using various means and methods are needed to increase immunisation coverage in adolescents before they leave school. An established method to determine vaccination coverage for the general population could provide invaluable insights into the effects of changes in vaccination policies and disease outbreaks.

  20. Increased immunization coverage addresses the equity gap in Nepal

    PubMed Central

    Nelin, Viktoria; Raaijmakers, Hendrikus; Kim, Hyung Joon; Singh, Chahana; Målqvist, Mats

    2017-01-01

    Abstract Objective To compare immunization coverage and equity distribution of coverage between 2001 and 2014 in Nepal. Methods We used data from the Demographic and Health Surveys carried out in 2001, 2006 and 2011 together with data from the 2014 Multiple Indicator Cluster Survey. We calculated the proportion, in mean percentage, of children who had received bacille Calmette–Guérin (BCG) vaccine, three doses of polio vaccine, three doses of diphtheria–pertussis–tetanus (DPT) vaccine and measles vaccine. To measure inequities between wealth quintiles, we calculated the slope index of inequality (SII) and relative index of inequality (RII) for all surveys. Findings From 2001 to 2014, the proportion of children who received all vaccines at the age of 12 months increased from 68.8% (95% confidence interval, CI: 67.5–70.1) to 82.4% (95% CI: 80.7–84.0). While coverage of BCG, DPT and measles immunization statistically increased during the study period, the proportion of children who received the third dose of polio vaccine decreased from 93.3% (95% CI: 92.7–93.9) to 88.1% (95% CI: 86.8–89.3). The poorest wealth quintile showed the greatest improvement in immunization coverage, from 58% to 77.9%, while the wealthiest quintile only improved from 84.8% to 86.0%. The SII for children who received all vaccines improved from 0.070 (95% CI: 0.061–0.078) to 0.026 (95% CI: 0.013–0.039) and RII improved from 1.13 to 1.03. Conclusion The improvement in immunization coverage between 2001 and 2014 in Nepal can mainly be attributed to the interventions targeting the disadvantaged populations. PMID:28479621

  1. Doses per vaccine vial container: An understated and underestimated driver of performance that needs more evidence.

    PubMed

    Heaton, Alexis; Krudwig, Kirstin; Lorenson, Tina; Burgess, Craig; Cunningham, Andrew; Steinglass, Robert

    2017-04-19

    The widespread use of multidose vaccine containers in low and middle income countries' immunization programs is assumed to have multiple benefits and efficiencies for health systems, yet the broader impacts on immunization coverage, costs, and safety are not well understood. To document what is known on this topic, how it has been studied, and confirm the gaps in evidence that allow us to assess the complex system interactions, the authors undertook a review of published literature that explored the relationship between doses per container and immunization systems. The relationships examined in this study are organized within a systems framework consisting of operational costs, timely coverage, safety, product costs/wastage, and policy/correct use, with the idea that a change in dose per container affects all of them, and the optimal solution will depend on what is prioritized and used to measure performance. Studies on this topic are limited and largely rely on modeling to assess the relationship between doses per container and other aspects of immunization systems. Very few studies attempt to look at how a change in doses per container affects vaccination coverage rates and other systems components simultaneously. This article summarizes the published knowledge on this topic to date and suggests areas of current and future research to ultimately improve decision making around vaccine doses per container and increase understanding of how this decision relates to other program goals. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  2. The Influence of Changes in Tumor Hypoxia on Dose-Painting Treatment Plans Based on {sup 18}F-FMISO Positron Emission Tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin Zhixiong; Mechalakos, James; Nehmeh, Sadek

    2008-03-15

    Purpose: To evaluate how changes in tumor hypoxia, according to serial fluorine-18-labeled fluoro-misonidazole ({sup 18}F-FMISO) positron emission tomography (PET) imaging, affect the efficacy of intensity-modulated radiotherapy (IMRT) dose painting. Methods and Materials: Seven patients with head and neck cancers were imaged twice with FMISO PET, separated by 3 days, before radiotherapy. Intensity-modulated radiotherapy plans were designed, on the basis of the first FMISO scan, to deliver a boost dose of 14 Gy to the hypoxic volume, in addition to the 70-Gy prescription dose. The same plans were then applied to hypoxic volumes from the second FMISO scan, and the efficacymore » of dose painting evaluated by assessing coverage of the hypoxic volumes using D{sub max}, D{sub min}, D{sub mean}, D{sub 95}, and equivalent uniform dose (EUD). Results: Similar hypoxic volumes were observed in the serial scans for 3 patients but dissimilar ones for the other 4. There was reduced coverage of hypoxic volumes of the second FMISO scan relative to that of the first scan (e.g., the average EUD decreased from 87 Gy to 80 Gy). The decrease was dependent on the similarity of the hypoxic volumes of the two scans (e.g., the average EUD decrease was approximately 4 Gy for patients with similar hypoxic volumes and approximately 12 Gy for patients with dissimilar ones). Conclusions: The changes in spatial distribution of tumor hypoxia, as detected in serial FMISO PET imaging, compromised the coverage of hypoxic tumor volumes achievable by dose-painting IMRT. However, dose painting always increased the EUD of the hypoxic volumes.« less

  3. Receipt of human papillomavirus vaccine among privately insured adult women in a U.S. Midwestern Health Maintenance Organization.

    PubMed

    Kharbanda, Elyse Olshen; Parker, Emily; Nordin, James D; Hedblom, Brita; Rolnick, Sharon J

    2013-11-01

    To describe human papillomavirus (HPV) vaccine coverage among adult privately insured women including variation in coverage by race/ethnicity. This cross-sectional, observational study included women 18-26 years of age with continuous enrollment in a U.S. Midwestern health insurance plan and at least one visit to a plan affiliated practice. Vaccination data came from insurance claims and the electronic medical record. Primary outcomes were: receipt of at least 1 HPV vaccine (HPV1) and completion of the 3-dose HPV vaccine series (HPV3). Coverage was described for the entire cohort and stratified by race/ethnicity. For a subset of women, automated data was compared to personal recall. As of June 2010, among 2546 privately insured women 18-26 years, 72.7% had received their first HPV vaccine and 57.9% completed the 3-dose series. Compared to white women, African American and Asian women had significantly lower coverage for HPV1 and HPV3. There was 94.5% (95% CI: 88.5-100%) agreement between personal recall and claims/EMR for receiving HPV1. In this cohort of privately insured women, a majority received HPV1 and more than half completed the 3-dose vaccine series. Marked disparities in receipt of HPV vaccine by race/ethnicity were observed. © 2013.

  4. Evaluating which plan quality metrics are appropriate for use in lung SBRT.

    PubMed

    Yaparpalvi, Ravindra; Garg, Madhur K; Shen, Jin; Bodner, William R; Mynampati, Dinesh K; Gafar, Aleiya; Kuo, Hsiang-Chi; Basavatia, Amar K; Ohri, Nitin; Hong, Linda X; Kalnicki, Shalom; Tome, Wolfgang A

    2018-02-01

    Several dose metrics in the categories-homogeneity, coverage, conformity and gradient have been proposed in literature for evaluating treatment plan quality. In this study, we applied these metrics to characterize and identify the plan quality metrics that would merit plan quality assessment in lung stereotactic body radiation therapy (SBRT) dose distributions. Treatment plans of 90 lung SBRT patients, comprising 91 targets, treated in our institution were retrospectively reviewed. Dose calculations were performed using anisotropic analytical algorithm (AAA) with heterogeneity correction. A literature review on published plan quality metrics in the categories-coverage, homogeneity, conformity and gradient was performed. For each patient, using dose-volume histogram data, plan quality metric values were quantified and analysed. For the study, the radiation therapy oncology group (RTOG) defined plan quality metrics were: coverage (0.90 ± 0.08); homogeneity (1.27 ± 0.07); conformity (1.03 ± 0.07) and gradient (4.40 ± 0.80). Geometric conformity strongly correlated with conformity index (p < 0.0001). Gradient measures strongly correlated with target volume (p < 0.0001). The RTOG lung SBRT protocol advocated conformity guidelines for prescribed dose in all categories were met in ≥94% of cases. The proportion of total lung volume receiving doses of 20 Gy and 5 Gy (V 20 and V 5 ) were mean 4.8% (±3.2) and 16.4% (±9.2), respectively. Based on our study analyses, we recommend the following metrics as appropriate surrogates for establishing SBRT lung plan quality guidelines-coverage % (ICRU 62), conformity (CN or CI Paddick ) and gradient (R 50% ). Furthermore, we strongly recommend that RTOG lung SBRT protocols adopt either CN or CI Padddick in place of prescription isodose to target volume ratio for conformity index evaluation. Advances in knowledge: Our study metrics are valuable tools for establishing lung SBRT plan quality guidelines.

  5. The value of male human papillomavirus vaccination in preventing cervical cancer and genital warts in a low-resource setting.

    PubMed

    Sharma, M; Sy, S; Kim, J J

    2016-05-01

    To estimate health benefits and incremental cost-effectiveness of human papillomavirus (HPV) vaccination of pre-adolescent boys and girls compared with girls alone for preventing cervical cancer and genital warts. Model-based economic evaluation. Southern Vietnam. Males and females aged ≥9 years. We simulated dynamic HPV transmission to estimate cervical cancer and genital warts cases. Models were calibrated to epidemiological data from south Vietnam. Incremental cost-effectiveness ratios (ICERs): cost per quality-adjusted life-year (QALY). Vaccinating girls alone was associated with reductions in lifetime cervical cancer risk ranging from 20 to 56.9% as coverage varied from 25 to 90%. Adding boys to the vaccination programme yielded marginal incremental benefits (≤3.6% higher absolute cervical cancer risk reduction), compared with vaccinating girls alone at all coverages. At ≤25 international dollars (I$) per vaccinated adolescent (I$5 per dose), HPV vaccination of boys was below the threshold of Vietnam's per-capita GDP (I$2800), with ICERs ranging from I$734 per QALY at 25% coverage to I$2064 per QALY for 90% coverage. Including health benefits from averting genital warts yielded more favourable ICERs, and vaccination of boys at I$10/dose became cost-effective at or below 75% coverage. Using a lower cost-effectiveness threshold of 50% of Vietnam's GDP (I$1400), vaccinating boys was no longer attractive at costs above I$5 per dose regardless of coverage. Vaccination of boys may be cost-effective at low vaccine costs, but provides little benefit over vaccinating girls only. Focusing on achieving high vaccine coverage of girls may be more efficient for southern Vietnam and similar low-resource settings. Limited cervical cancer reduction from including boys in HPV vaccination of girls in low-resource settings. © 2015 Royal College of Obstetricians and Gynaecologists.

  6. Analysis of incidental radiation dose to uninvolved mediastinal/supraclavicular lymph nodes in patients with limited-stage small cell lung cancer treated without elective nodal irradiation.

    PubMed

    Ahmed, Irfan; DeMarco, Marylou; Stevens, Craig W; Fulp, William J; Dilling, Thomas J

    2011-01-01

    Classic teaching states that treatment of limited-stage small cell lung cancer (L-SCLC) requires large treatment fields covering the entire mediastinum. However, a trend in modern thoracic radiotherapy is toward more conformal fields, employing positron emission tomography/computed tomography (PET/CT) scans to determine the gross tumor volume (GTV). This analysis evaluates the dosimetric results when using selective nodal irradiation (SNI) to treat a patient with L-SCLC, quantitatively comparing the results to standard Intergroup treatment fields. Sixteen consecutive patients with L-SCLC and central mediastinal disease who also underwent pretherapy PET/CT scans were studied in this analysis. For each patient, we created SNI treatment volumes, based on the PET/CT-based criteria for malignancy. We also created 2 ENI plans, the first without heterogeneity corrections, as per the Intergroup 0096 study (ENI(off)) and the second with heterogeneity corrections while maintaining constant the number of MUs delivered between these latter 2 plans (ENI(on)). Nodal stations were contoured using published guidelines, then placed into 4 "bins" (treated nodes, 1 echelon away, >1 echelon away within the mediastinum, contralateral hilar/supraclavicular). These were aggregated across the patients in the study. Dose to these nodal bins and to tumor/normal structures were compared among these plans using pairwise t-tests. The ENI(on) plans demonstrated a statistically significant degradation in dose coverage compared with the ENI(off) plans. ENI and SNI both created a dose gradient to the lymph nodes across the mediastinum. Overall, the gradient was larger for the SNI plans, although the maximum dose to the "1 echelon away" nodes was not statistically different. Coverage of the GTV and planning target volume (PTV) were improved with SNI, while simultaneously reducing esophageal and spinal cord dose though at the expense of modestly reduced dose to anatomically distant lymph nodes within the mediastinum. The ENI(on) plans demonstrate that intergroup-style treatments, as actually delivered, had statistically reduced coverage to the mediastinum and tumor volumes than was reported. Furthermore, SNI leads to improved tumor coverage and reduced esophageal/spinal cord dose, which suggests the possibility of dose escalation using SNI. Copyright © 2011 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  7. Achieving high uptake of human papillomavirus vaccine in Cameroon: lessons learned in overcoming challenges.

    PubMed

    Ogembo, Javier Gordon; Manga, Simon; Nulah, Kathleen; Foglabenchi, Lily H; Perlman, Stacey; Wamai, Richard G; Welty, Thomas; Welty, Edith; Tih, Pius

    2014-07-31

    Cameroon has the highest age-standardized incidence rate of cervical cancer (30/100,000 women) in Central Africa. In 2010-2011, the Cameroon Baptist Convention Health Services (CBCHS) received donated human papillomavirus (HPV) vaccine, Gardasil, from Merck & Co. Inc. through Axios Healthcare Development to immunize 6400 girls aged 9-13 years. The aim was to inform the Cameroon Ministry of Health (MOH) of the acceptability, feasibility, and optimal delivery strategies for HPV vaccine. Following approval by the MOH, CBCHS nurses educated girls, parents, and communities about HPV, cervical cancer, and HPV vaccine through multimedia coverage, brochures, posters, and presentations. Because educators were initially reluctant to allow immunization in schools, due to fear of adverse events, the nurses performed 40.7% of vaccinations in the clinics, 34.5% in community venues, and only 24.7% in schools. When no adverse events were reported, more schools and communities permitted HPV vaccine immunization on their premises. To recover administrative costs, CBCHS charged a fee of US$8 per 3-dose series only to those who were able to pay. Despite the fee, 84.6% of the 6,851 girls who received the first dose received all three doses. With adequate education of all stakeholders, HPV vaccination is acceptable and feasible in Cameroon. Following this demonstration project, in 2014 the Global Access to Vaccines and Immunization (GAVI) Alliance awarded the Cameroon MOH HPV vaccine at a price of US$4.50 per dose to immunize sixth grade girls and girls aged 10 years who are not in school in two districts of Cameroon. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Analysis of Intensity-Modulated Radiation Therapy (IMRT), Proton and 3D Conformal Radiotherapy (3D-CRT) for Reducing Perioperative Cardiopulmonary Complications in Esophageal Cancer Patients.

    PubMed

    Ling, Ted C; Slater, Jerry M; Nookala, Prashanth; Mifflin, Rachel; Grove, Roger; Ly, Anh M; Patyal, Baldev; Slater, Jerry D; Yang, Gary Y

    2014-12-05

    Background. While neoadjuvant concurrent chemoradiotherapy has improved outcomes for esophageal cancer patients, surgical complication rates remain high. The most frequent perioperative complications after trimodality therapy were cardiopulmonary in nature. The radiation modality utilized can be a strong mitigating factor of perioperative complications given the location of the esophagus and its proximity to the heart and lungs. The purpose of this study is to make a dosimetric comparison of Intensity-Modulated Radiation Therapy (IMRT), proton and 3D conformal radiotherapy (3D-CRT) with regard to reducing perioperative cardiopulmonary complications in esophageal cancer patients. Materials. Ten patients with esophageal cancer treated between 2010 and 2013 were evaluated in this study. All patients were simulated with contrast-enhanced CT imaging. Separate treatment plans using proton radiotherapy, IMRT, and 3D-CRT modalities were created for each patient. Dose-volume histograms were calculated and analyzed to compare plans between the three modalities. The organs at risk (OAR) being evaluated in this study are the heart, lungs, and spinal cord. To determine statistical significance, ANOVA and two-tailed paired t-tests were performed for all data parameters. Results. The proton plans showed decreased dose to various volumes of the heart and lungs in comparison to both the IMRT and 3D-CRT plans. There was no difference between the IMRT and 3D-CRT plans in dose delivered to the lung or heart. This finding was seen consistently across the parameters analyzed in this study. Conclusions. In patients receiving radiation therapy for esophageal cancer, proton plans are technically feasible while achieving adequate coverage with lower doses delivered to the lungs and cardiac structures. This may result in decreased cardiopulmonary toxicity and less morbidity to esophageal cancer patients.

  9. Quality Control of Involved Field Radiotherapy in Patients With Early-Favorable (HD10) and Early-Unfavorable (HD11) Hodgkin's Lymphoma: An Analysis of the German Hodgkin Study Group

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eich, Hans Theodor; Engenhart-Cabillic, Rita; Hansemann, Katja

    2008-08-01

    Purpose: The German Hodgkin Study Group (GHSG) set up a radiotherapy (RT) reference center within the Department of Radiation Oncology at University of Cologne to undertake quality assurance of the group's clinical studies. In the HD10 trial (early-favorable stages) and HD11 trial (early-unfavorable stages) all patients received involved field (IF)-RT (30 Gy vs. 20 Gy) within a combined-modality approach. For these patients a central prospective review of all diagnostic imaging was performed by expert radiation oncologists to control disease extension and to define IF treatment volume. Methods and Materials: On the basis of simulation films, verification films, and radiotherapy casemore » report form (CRF) an expert panel evaluated retrospectively the adequacy of irradiated IF treatment portals according to the RT prescription, applied radiation doses, treatment time, and technical parameters. Results: Between 1999 and 2006 a total of 825 of 1370 randomized patients of the HD10 trial (60%) and 954 of 1422 patients of the HD11 trial (67%) were evaluated by the panel. Radiotherapy was rated as suboptimal in 47% of all reviewed cases. Although the participating RT centers received a precise RT prescription, most difficulties occurred in the adequate coverage of the IF (40%), followed by technical faults (12%). Deviations from the prescribed single daily dose (1.8-2 Gy), weekly dose, and total reference dose were rare (1%). Conclusions: As a consequence of these findings, radiation oncologists were trained on the definition of IF-RT at GHSG meetings and at the annual meetings of the German Society for Therapeutic Radiation Oncology. Possible correlations between RT quality and relapse rate will be investigated.« less

  10. Analysis of Intensity-Modulated Radiation Therapy (IMRT), Proton and 3D Conformal Radiotherapy (3D-CRT) for Reducing Perioperative Cardiopulmonary Complications in Esophageal Cancer Patients

    PubMed Central

    Ling, Ted C.; Slater, Jerry M.; Nookala, Prashanth; Mifflin, Rachel; Grove, Roger; Ly, Anh M.; Patyal, Baldev; Slater, Jerry D.; Yang, Gary Y.

    2014-01-01

    Background. While neoadjuvant concurrent chemoradiotherapy has improved outcomes for esophageal cancer patients, surgical complication rates remain high. The most frequent perioperative complications after trimodality therapy were cardiopulmonary in nature. The radiation modality utilized can be a strong mitigating factor of perioperative complications given the location of the esophagus and its proximity to the heart and lungs. The purpose of this study is to make a dosimetric comparison of Intensity-Modulated Radiation Therapy (IMRT), proton and 3D conformal radiotherapy (3D-CRT) with regard to reducing perioperative cardiopulmonary complications in esophageal cancer patients. Materials. Ten patients with esophageal cancer treated between 2010 and 2013 were evaluated in this study. All patients were simulated with contrast-enhanced CT imaging. Separate treatment plans using proton radiotherapy, IMRT, and 3D-CRT modalities were created for each patient. Dose-volume histograms were calculated and analyzed to compare plans between the three modalities. The organs at risk (OAR) being evaluated in this study are the heart, lungs, and spinal cord. To determine statistical significance, ANOVA and two-tailed paired t-tests were performed for all data parameters. Results. The proton plans showed decreased dose to various volumes of the heart and lungs in comparison to both the IMRT and 3D-CRT plans. There was no difference between the IMRT and 3D-CRT plans in dose delivered to the lung or heart. This finding was seen consistently across the parameters analyzed in this study. Conclusions. In patients receiving radiation therapy for esophageal cancer, proton plans are technically feasible while achieving adequate coverage with lower doses delivered to the lungs and cardiac structures. This may result in decreased cardiopulmonary toxicity and less morbidity to esophageal cancer patients. PMID:25489937

  11. Racial/ethnic differences in health insurance adequacy and consistency among children: Evidence from the 2011/12 National Survey of Children's Health.

    PubMed

    Soylu, Tulay G; Elashkar, Eman; Aloudah, Fatemah; Ahmed, Munir; Kitsantas, Panagiota

    2018-02-05

    Surveillance of disparities in healthcare insurance, services and quality of care among children are critical for properly serving the medical/healthcare needs of underserved populations. The purpose of this study was to assess racial/ethnic differences in children's (0 to 17 years old) health insurance adequacy and consistency (child has insurance coverage for the last 12 months). We used data from the 2011/2012 National Survey of Children's Health (n=79,474). Descriptive statistics and logistic regression analyses were conducted to examine the distribution and influence of several sociodemographic/family related factors on insurance adequacy and consistency across different racial/ethnic groups. Stratified analyses by race/ethnicity revealed that white and black children living in households at or below 299% of the Federal Poverty Level (FPL) were approximately 29 to 42% less likely to have adequate insurance compared to children living in families of higher income levels. Regardless of race/ethnicity, we found that children with public health insurance were more likely to have adequate insurance than their privately insured counterparts, while adolescents were at greater risk of inadequate coverage. Hispanic and black children were more likely to lack consistent insurance coverage. This study provides evidence that racial/ethnic differences in adequate and consistent health insurance exists with both white and minority children being affected adversely by poverty. Establishing outreach programs for low income families, and cross-cultural education for healthcare providers may help increase health insurance adequacy and consistency within certain underserved populations.

  12. SU-E-T-175: Clinical Evaluations of Monte Carlo-Based Inverse Treatment Plan Optimization for Intensity Modulated Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chi, Y; Li, Y; Tian, Z

    2015-06-15

    Purpose: Pencil-beam or superposition-convolution type dose calculation algorithms are routinely used in inverse plan optimization for intensity modulated radiation therapy (IMRT). However, due to their limited accuracy in some challenging cases, e.g. lung, the resulting dose may lose its optimality after being recomputed using an accurate algorithm, e.g. Monte Carlo (MC). It is the objective of this study to evaluate the feasibility and advantages of a new method to include MC in the treatment planning process. Methods: We developed a scheme to iteratively perform MC-based beamlet dose calculations and plan optimization. In the MC stage, a GPU-based dose engine wasmore » used and the particle number sampled from a beamlet was proportional to its optimized fluence from the previous step. We tested this scheme in four lung cancer IMRT cases. For each case, the original plan dose, plan dose re-computed by MC, and dose optimized by our scheme were obtained. Clinically relevant dosimetric quantities in these three plans were compared. Results: Although the original plan achieved a satisfactory PDV dose coverage, after re-computing doses using MC method, it was found that the PTV D95% were reduced by 4.60%–6.67%. After re-optimizing these cases with our scheme, the PTV coverage was improved to the same level as in the original plan, while the critical OAR coverages were maintained to clinically acceptable levels. Regarding the computation time, it took on average 144 sec per case using only one GPU card, including both MC-based beamlet dose calculation and treatment plan optimization. Conclusion: The achieved dosimetric gains and high computational efficiency indicate the feasibility and advantages of the proposed MC-based IMRT optimization method. Comprehensive validations in more patient cases are in progress.« less

  13. SU-F-T-198: Dosimetric Comparison of Carbon and Proton Radiotherapy for Recurrent Nasopharynx Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheng, Y; Zhao, J; Wang, W

    2016-06-15

    Purpose: Various radiotherapy planning methods for locally recurrent nasopharynx carcinoma (R-NPC) have been proposed. The purpose of this study was to compare carbon and proton therapy for the treatment of R-NPC in terms of dose coverage for target volume and sparing for organs at risk (OARs). Methods: Six patients who were suffering from R-NPC and treated using carbon therapy were selected for this study. Treatment plans with a total dose of 57.5Gy (RBE) in 23 fractions were made using SIEMENS Syngo V11. An intensity-modulated radiotherapy optimization method was chosen for carbon plans (IMCT) while for proton plans both intensity-modulated radiotherapymore » (IMPT) and single beam optimization (proton-SBO) methods were chosen. Dose distributions, dose volume parameters, and selected dosimetric indices for target volumes and OARs were compared for all treatment plans. Results: All plans provided comparable PTV coverage. The volume covered by 95% of the prescribed dose was comparable for all three plans. The average values were 96.11%, 96.24% and 96.11% for IMCT, IMPT, and proton-SBO respectively. A significant reduction of the 80% and 50% dose volumes were observed for the IMCT plans compared to the IMPT and proton-SBO plans. Critical organs lateral to the target such as brain stem and spinal cord were better spared by IMPT than by proton-SBO, while IMCT spared those organs best. For organs in the beam path, such as parotid glands, the mean dose results were similar for all three plans. Conclusion: Carbon plans yielded better dose conformity than proton plans. They provided similar or better target coverage while significantly lowering the dose for normal tissues. Dose sparing for critical organs in IMPT plans was better than proton-SBO, however, IMPT is known to be more sensitive to range uncertainties. For proton plans it is essential to find a balance between the two optimization methods.« less

  14. SU-F-T-520: Dosimetric Comparison of Radiation Treatment Plans for Whole Breast Irradiation Between 3D Conformal in Prone and Supine Positions Vs. VMAT and IMRT in Supine Positions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bejarano Buele, A; Parsai, E

    Purpose: The target volume for Whole Breast Irradiation (WBI) is dictated by location of tumor mass, breast tissue distribution, and involvement of lymph nodes. Dose coverage and Organs at Risk (OARs) sparing can be difficult to achieve in patients with unfavorable thoracic geometries. For these cases, inverse-planned and 3D-conformal prone treatments can be alternatives to traditional supine 3D-conformal plans. A dosimetric comparison can determine which of these techniques achieve optimal target coverage while sparing OARs. Methods: This study included simulation datasets for 8 patients, 5 of whom were simulated in both supine and prone positions. Positioning devices included breast boardsmore » and Vaclok bags for the supine position, and prone breast boards for the prone position. WBI 3-D conformal plans were created for patients simulated in both positions. Additional VMAT and IMRT WBI plans were made for all patients in the supine position. Results: Prone and supine 3D conformal plans had comparable PTV coverage. Prone 3D conformal plans received a significant 50% decrease to V20, V10, V5 and V30% for the ipsilateral lung in contrast to the supine plans. The heart also experienced a 10% decrease in maximum dose in the prone position, and V20, V10, V5 and V2 had significantly lower values than the supine plan. Supine IMRT and VMAT breast plans obtained comparable PTV coverage. The heart experienced a 10% decrease in maximum dose with inverse modulated plans when compared to the supine 3D conformal plan, while V20, V10, V5 and V2 showed higher values with inverse modulated plans than with supine 3D conformal plans. Conclusion: Prone 3D-conformal, and supine inverse planned treatments were generally superior in sparing OARs to supine plans with comparable PTV coverage. IMRT and VMAT plans offer sparing of OARs from high dose regions with an increase of irradiated volume in the low dose regions.« less

  15. SU-E-J-86: Functional Conformal Planning for Stereotactic Body Radiation Therapy with CT-Pulmonary Ventilation Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurosawa, T; Moriya, S; Sato, M

    2015-06-15

    Purpose: To evaluate the functional planning using CT-pulmonary ventilation imaging for conformal SBRT. Methods: The CT-pulmonary ventilation image was generated using the Jacobian metric in the in-house program with the NiftyReg software package. Using the ventilation image, the normal lung was split into three lung regions for functionality (high, moderate and low). The anatomical plan (AP) and functional plan (FP) were made for ten lung SBRT patients. For the AP, the beam angles were optimized with the dose-volume constraints for the normal lung sparing and the PTV coverage. For the FP, the gantry angles were also optimized with the additionalmore » constraint for high functional lung. The MLC aperture shapes were adjusted to the PTV with the additional 5 mm margin. The dosimetric parameters for PTV, the functional volumes, spinal cord and so on were compared in both plans. Results: Compared to the AP, the FP showed better dose sparing for high- and moderate-functional lungs with similar PTV coverage while not taking care of the low functional lung (High:−12.9±9.26% Moderate: −2.0±7.09%, Low: +4.1±12.2%). For the other normal organs, the FP and AP showed similar dose sparing in the eight patients. However, the FP showed that the maximum doses for spinal cord were increased with the significant increment of 16.4Gy and 21.0Gy in other two patients, respectively. Because the beam direction optimizer chose the unexpected directions passing through the spinal cord. Conclusion: Even the functional conformal SBRT can selectively reduce high- and moderatefunctional lung while keeping the PTV coverage. However, it would be careful that the optimizer would choose unexpected beam angles and the dose sparing for the other normal organs can be worse. Therefore, the planner needs to control the dose-volume constraints and also limit the beam angles in order to achieve the expected dose sparing and coverage.« less

  16. SU-E-T-625: Potential for Reduced Radiation Induced Toxicity for the Treatment of Inoperable Non-Small-Cell Lung Cancer Using RapidArc Planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pokhrel, D; Sood, S; Badkul, R

    2015-06-15

    Purpose: To investigate the feasibility of using RapidArc (RA) treatment planning to reduce irradiation volume of normal lung and other organs at risk (OARs) in the treatment of inoperable non-small-cell lung cancer (NSCLC) patients. Methods: A retrospective treatment planning and delivery study was performed to compare target coverage and the volumes of the normal lung, spinal cord, heart and esophagus on 4D-CT scan above their dose tolerances delivered by RA vs. IMRT for ten inoperable NSCLC patients (Stage I-IIIB). RA plans consisted of either one-full or two-partial co-planar arcs used to treat 95% of the planning target volume (PTV) withmore » 6MV beam to a prescription of 66Gy in 33 fractions. IMRT plans were generated using 5–7 co-planar fields with 6MV beam. PTV coverage, dose-volume histograms, homogeneity/conformity indices (CI), total number of monitor units(MUs), beam-on time and delivery accuracy were compared between the two treatment plans. Results: Similar target coverage was obtained between the two techniques. RA (CI=1.02) provided more conformal plans without loss of homogeneity compared to IMRT plans (CI=1.12). Compared to IMRT, RA achieved a significant median dose reduction in V10 (3%), V20 (8%), and mean lung dose (3%) on average, respectively. On average, V5 was comparable between the two treatment plans. RA reduced mean esophagus (6%), mean heart (18%), and maximum spinal cord dose (7%), on average, respectively. Total number of MUs and beam-on time were each reduced almost by a factor of 2 when compared to IMRT-patient comfort, reduced intra-fraction-motion and leakage dose. The average IMRT and RA QA pass rate was about 98% for both types of plans for 3%/3mm criterion. Conclusion: Compared to IMRT plans, RA provided not only comparable target coverage, but also improved conformity, treatment time, and significant reduction in irradiation of OARs. This may potentially allow for target dose escalation without increase in normal tissue toxicity.« less

  17. The impact of active breathing control on internal mammary lymph node coverage and normal tissue exposure in breast cancer patients planned for left-sided postmastectomy radiation therapy.

    PubMed

    Barry, Aisling; Rock, Kathy; Sole, Claudio; Rahman, Mohammad; Pintilie, Melania; Lee, Grace; Fyles, Anthony; Koch, C Anne

    The purpose of this study was to evaluate the impact of the active breathing control (ABC) technique on IMN coverage and organs at risk in patients planned for postmastectomy radiation therapy (PMRT), with the inclusion of the internal mammary lymph nodes (IMNs). The effect of body mass index (BMI) on recorded dosimetric parameters was examined in the same patient cohort. Fifty left-sided postmastectomy patients with breast cancer who underwent free-breathing (FB) and ABC-Elekta CT simulation scans were selected at random from an institutional breast cancer database between 2008 and 2014. The ABC plans were directly compared with FB plans from the same patient. The IMN planning target volume coverage met dosimetric criteria for coverage of receiving more than 90% of the prescribed dose (V90) >90%, although it decreased with ABC compared with FB (94.5% vs 98%, P < .001). Overall, ABC significantly reduced doses to all measured heart and left anterior descending coronary artery parameters, ipsilateral lung V20, and mean lung dose compared with FB (P < .001). There was no difference seen between the ABC and FB plans with respect to the dose to contralateral lung or contralateral breast. There was no correlation identified between BMI and any of the dosimetric parameters recorded from the ABC and FB plans. Our results suggest that ABC reduces IMN coverage in left-sided breast cancer patients planned for PMRT; however, dosimetric criteria for IMN coverage were still met, suggesting that this is not likely to be clinically significant. ABC led to significant sparing of organs at risk compared with FB conditions and was not affected by BMI. Collectively, the results support the use of ABC for breast cancer patients undergoing left-sided PMRT requiring regional nodal irradiation that includes the IMNs. Further prospective clinical studies are required to determine the impact of these results on late normal tissue effects. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  18. Quality of radiotherapy reporting in randomized controlled trials of prostate cancer.

    PubMed

    Soon, Yu Yang; Chen, Desiree; Tan, Teng Hwee; Tey, Jeremy

    2018-06-07

    Good radiotherapy reporting in clinical trials of prostate radiotherapy is important because it will allow accurate reproducibility of radiotherapy treatment and minimize treatment variations that can affect patient outcomes. The aim of our study is to assess the quality of prostate radiotherapy (RT) treatment reporting in randomized controlled trials in prostate cancer. We searched MEDLINE for randomized trials of prostate cancer, published from 1996 to 2016 and included prostate RT as one of the intervention arms. We assessed if the investigators reported the ten criteria adequately in the trial reports: RT dose prescription method; RT dose-planning procedures; organs at risk (OAR) dose constraints; target volume definition, simulation procedures; treatment verification procedures; total RT dose; fractionation schedule; conduct of quality assurance (QA) as well as presence or absence of deviations in RT treatment planning and delivery. We performed multivariate logistic regression to determine the factors that may influence the quality of reporting. We found 59 eligible trials. There was significant variability in the quality of reporting. Target volume definition, total RT dose and fractionation schedule were reported adequately in 97% of included trials. OAR constraints, simulation procedures and presence or absence of deviations in RT treatment planning and delivery were reported adequately in 30% of included trials. Twenty-four trials (40%) reported seven criteria or more adequately. Multivariable logistic analysis showed that trials that published their quality assurance results and cooperative group trials were more likely to have adequate quality in reporting in at least seven criteria. There is significant variability in the quality of reporting on prostate radiotherapy treatment in randomized trials of prostate cancer. We need to have consensus guidelines to standardize the reporting of radiotherapy treatment in randomized trials.

  19. SU-E-T-309: Dosimetric Comparison of Simultaneous Integrated Boost Treatment Plan Between Intensity Modulated Radiotherapies (IMRTs), Dual Arc Volumetric Modulated Arc Therapy (DA-VMAT) and Single Arc Volumetric Modulated Arc Therapy (SA-VMAT) for Nasopharyngeal Carcinoma (NPC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sivakumar, R; Janardhan, N; Bhavani, P

    Purpose: To compare the plan quality and performance of Simultaneous Integrated Boost (SIB) Treatment plan between Seven field (7F) and Nine field(9F) Intensity Modulated Radiotherapies and Single Arc (SA) and Dual Arc (DA) Volumetric Modulated Arc Therapy( VMAT). Methods: Retrospective planning study of 16 patients treated in Elekta Synergy Platform (mlci2) by 9F-IMRT were replanned with 7F-IMRT, Single Arc VMAT and Dual Arc VMAT using CMS, Monaco Treatment Planning System (TPS) with Monte Carlo simulation. Target delineation done as per Radiation Therapy Oncology Protocols (RTOG 0225&0615). Dose Prescribed as 70Gy to Planning Target Volumes (PTV70) and 61Gy to PTV61 inmore » 33 fraction as a SIB technique. Conformity Index(CI), Homogeneity Index(HI) were used as analysis parameter for Target Volumes as well as Mean dose and Max dose for Organ at Risk(OAR,s).Treatment Delivery Time(min), Monitor unit per fraction (MU/fraction), Patient specific quality assurance were also analysed. Results: A Poor dose coverage and Conformity index (CI) was observed in PTV70 by 7F-IMRT among other techniques. SA-VMAT achieved poor dose coverage in PTV61. No statistical significance difference observed in OAR,s except Spinal cord (P= 0.03) and Right optic nerve (P=0.03). DA-VMAT achieved superior target coverage, higher CI (P =0.02) and Better HI (P=0.03) for PTV70 other techniques (7F-IMRT/9F-IMRT/SA-VMAT). A better dose spare for Parotid glands and spinal cord were seen in DA-VMAT. The average treatment delivery time were 5.82mins, 6.72mins, 3.24mins, 4.3mins for 7F-IMRT, 9F-IMRT, SA-VMAT and DA-VMAT respectively. Significance difference Observed in MU/fr (P <0.001) and Patient quality assurance pass rate were >95% (Gamma analysis (Γ3mm, 3%). Conclusion: DA-VAMT showed better target dose coverage and achieved better or equal performance in sparing OARs among other techniques. SA-VMAT offered least Treatment Time than other techniques but achieved poor target coverage. DA-VMAT offered shorter delivery time than 7F-IMRT and 9F-IMRT without compromising the plan quality.« less

  20. Clinical decision tool for optimal delivery of liver stereotactic body radiation therapy: Photons versus protons.

    PubMed

    Gandhi, Saumil J; Liang, Xing; Ding, Xuanfeng; Zhu, Timothy C; Ben-Josef, Edgar; Plastaras, John P; Metz, James M; Both, Stefan; Apisarnthanarax, Smith

    2015-01-01

    Stereotactic body radiation therapy (SBRT) for treatment of liver tumors is often limited by liver dose constraints. Protons offer potential for more liver sparing, but clinical situations in which protons may be superior to photons are not well described. We developed and validated a treatment decision model to determine whether liver tumors of certain sizes and locations are more suited for photon versus proton SBRT. Six spherical mock tumors from 1 to 6 cm in diameter were contoured on computed tomography images of 1 patient at 4 locations: dome, caudal, left medial, and central. Photon and proton plans were generated to deliver 50 Gy in 5 fractions to each tumor and optimized to deliver equivalent target coverage and maximal liver sparing. Using these plans, we developed a hypothesis-generating model to predict the optimal modality for maximal liver sparing based on tumor size and location. We then validated this model in 10 patients with liver tumors. Protons spared significantly more liver than photons for dome or central tumors ≥3 cm (dome: 134 ± 21 cm(3), P = .03; central: 108 ± 4 cm(3), P = .01). Our model correctly predicted the optimal SBRT modality for all 10 patients. For patients with dome or central tumors ≥3 cm, protons significantly increased the volume of liver spared (176 ± 21 cm(3), P = .01) and decreased the mean liver dose (8.4 vs 12.2 Gy, P = .01) while offering no significant advantage for tumors <3 cm at any location or for caudal and left medial tumors of any size. When feasible, protons should be considered as the radiation modality of choice for dome and central tumors >3 cm to allow maximal liver sparing and potentially reduce radiation toxicity. Protons should also be considered for any tumor >5 cm if photon plans fail to achieve adequate coverage or exceed the mean liver threshold. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  1. [Varicella vaccine effectiveness in schoolchildren in outbreaks in a semi-urban area].

    PubMed

    Romera-Guirado, F J; Molina-Salas, Y; Pérez-Martín, J J; Ruzafa-Martínez, M

    2016-01-01

    To estimate the effectiveness of the varicella vaccine in school outbreaks during the academic year 2009-2010. Retrospective cohort study in public day-care centers and/or schools in an area in the region of Murcia. Spain. The participants were all children of 1 to 12 years who were in the same classroom where there was an outbreak of varicella. The main measurements were the sociodemographic, clinical and vaccination data, as well as variables related to varicella disease obtained through a questionnaire self-completed by parents, and from the computerized regional immunization registry (VACUSAN). A total of 51 varicella outbreaks were detected, with a median of 3 cases per outbreak at both educational levels. The overall vaccination coverage was 10.7% (95% CI 8.63 to 13.18), always being higher in Spanish schoolchildren versus foreign (OR: 21.21, 95% CI: 2.92 to 153.92, P<.001). Discrepancies were found between the vaccine questionnaire data and vaccination program (kappa=0.50, 95% CI: 0.43 to 0.58, P<.001). According to VACUSAN, the overall attack rate was 59.7 (95% CI: 55.82 to 63.43) in unvaccinated and 6.5 (95% CI: 2.54 to 15.45) in vaccinated children. An overall effectiveness of 89.1% (95% CI: 74.55 to 95.35) and 100% was obtained for 1 and 2 doses of vaccine, respectively. There is a high effectiveness of varicella vaccine, emphasizing that the administration of two doses of vaccine produces an adequate and optimal protection against varicella disease. A discrepancy was found between the information provided by parents and official records. Finally, there was a lower vaccination coverage in the immigrant community. Copyright © 2014 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  2. Single-Isocenter Multiple-Target Stereotactic Radiosurgery: Risk of Compromised Coverage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roper, Justin, E-mail: justin.roper@emory.edu; Department of Biostatistics and Bioinformatics, Winship Cancer Institute of Emory University, Atlanta, Georgia; Chanyavanich, Vorakarn

    2015-11-01

    Purpose: To determine the dosimetric effects of rotational errors on target coverage using volumetric modulated arc therapy (VMAT) for multitarget stereotactic radiosurgery (SRS). Methods and Materials: This retrospective study included 50 SRS cases, each with 2 intracranial planning target volumes (PTVs). Both PTVs were planned for simultaneous treatment to 21 Gy using a single-isocenter, noncoplanar VMAT SRS technique. Rotational errors of 0.5°, 1.0°, and 2.0° were simulated about all axes. The dose to 95% of the PTV (D95) and the volume covered by 95% of the prescribed dose (V95) were evaluated using multivariate analysis to determine how PTV coverage was relatedmore » to PTV volume, PTV separation, and rotational error. Results: At 0.5° rotational error, D95 values and V95 coverage rates were ≥95% in all cases. For rotational errors of 1.0°, 7% of targets had D95 and V95 values <95%. Coverage worsened substantially when the rotational error increased to 2.0°: D95 and V95 values were >95% for only 63% of the targets. Multivariate analysis showed that PTV volume and distance to isocenter were strong predictors of target coverage. Conclusions: The effects of rotational errors on target coverage were studied across a broad range of SRS cases. In general, the risk of compromised coverage increased with decreasing target volume, increasing rotational error and increasing distance between targets. Multivariate regression models from this study may be used to quantify the dosimetric effects of rotational errors on target coverage given patient-specific input parameters of PTV volume and distance to isocenter.« less

  3. Extended release amoxicillin/clavulanate: optimizing a product for respiratory infections based on pharmacodynamic principles.

    PubMed

    Jacobs, Michael R

    2005-06-01

    Acute bacterial respiratory tract infections cause a great deal of human morbidity and mortality. Treatment guidelines for these infections include macrolides, doxycycline, beta-lactams and beta-lactam/beta-lactamase inhibitor combinations such as amoxicillin/clavulanic acid to provide coverage for the common respiratory pathogens, including penicillin and macrolide nonsusceptible Streptococcus pneumoniae, as well as beta-lactamase-producing Haemophilus influenzae and Moraxella catarrhalis. In response to recent guidelines recommending higher dose amoxicillin to extend coverage to a higher percentage of S. pneumoniae, a new formulation of amoxicillin/clavulanic acid was developed. This formulation includes a higher amoxicillin dose, with part of the amoxicillin dose being in an extended release formulation, without increasing the clavulanate dose, for twice-daily oral treatment of these infections. Clinical studies of community-acquired pneumonia and acute rhinosinusitis have shown that the new formulation is well tolerated and highly efficacious, with clinical outcomes equivalent to comparators.

  4. Infantry Weapons Test Methodology Study. Volume 3. Light Machine Gun Test Methodology

    DTIC Science & Technology

    1972-06-01

    Trajjectnry and marionim ordiwate. to the target increases beyond 500 meters, the beaten zone will become shorter and wider. When fires are de - livered into...traversing amount of elevation change is de - handwheel. To insure adequate tar- termined by the slope of the terrain get coverage, a burst is fired after and...to the traversing handwheel. The 6-mii increments on the traversing amount of elevation change Is de - handwheel. To insure adequate tar- termined by

  5. Initial Report of a Prospective Dosimetric and Clinical Feasibility Trial Demonstrates the Potential of Protons to Increase the Therapeutic Ratio in Breast Cancer Compared With Photons.

    PubMed

    Bradley, Julie A; Dagan, Roi; Ho, Meng Wei; Rutenberg, Michael; Morris, Christopher G; Li, Zuofeng; Mendenhall, Nancy P

    2016-05-01

    To compare dosimetric endpoints between proton therapy (PT) and conventional radiation and determine the feasibility of PT for regional nodal irradiation (RNI) in women with breast cancer. From 2012 to 2014, 18 women (stage IIA-IIIB) requiring RNI prospectively enrolled on a pilot study. Median age was 51.8 years (range, 42-73 years). The cohort included breast-conserving therapy (BCT) and mastectomy patients and right- and left-sided cancers. Treatment targets and organs at risk were delineated on computed tomography scans, and PT and conventional plans were developed. Toxicity was prospectively recorded using Common Terminology Criteria for Adverse Events version 4.0. A Wilcoxon signed-rank sum test compared the dose-volume parameters. The primary endpoint was a reduction in cardiac V5. Median follow-up was 20 months (range, 2-31 months). For all patients, the PT plan better met the dosimetric goals and was used for treatment. Proton therapy alone was used for 10 patients (9 postmastectomy, 1 after BCT) and combined proton-photon in 8 (6 BCT, 2 postmastectomy with immediate expander reconstruction). Proton therapy improved coverage of level 2 axilla (P=.0005). Adequate coverage of internal mammary nodes was consistently achieved with PT (median D95, 50.3 Gy; range, 46.6-52.1 Gy) but not with conventional radiation therapy (median D95, 48.2 Gy; range, 40.8-55 Gy; P=.0005). Median cardiac V5 was 0.6% with PT and 16.3% with conventional radiation (P<.0001). Median ipsilateral lung V5 and V20 were improved with PT (median V5 35.3% vs 60.5% [P<.0001]; and median V20, 21.6% vs 35.5% [P<.0001]). Grade 3 dermatitis developed in 4 patients (22%), which was the only grade 3 toxicity. No grade 4+ toxicities developed. Proton therapy for RNI after mastectomy or BCT significantly improves cardiac dose, especially for left-sided patients, and lung V5 and V20 in all patients without excessive acute toxicity. Proton therapy simultaneously improves target coverage for the internal mammary nodes and level 2 axilla, which may positively impact long-term survival in breast cancer patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Coverage Root after Removing Peripheral Ossifying Fibroma: 5-Year Follow-Up Case Report

    PubMed Central

    Okajima, Luciana S.; Nunes, Marcelo P.; Montalli, Victor A. M.

    2016-01-01

    When lesions in soft tissue reach the gingival margin, they can produce aesthetic defects during its permanence and after its removal. Periodontal plastic surgery allows the correction of the gingival contour using different techniques. This paper is a case report of a peripheral ossifying fibroma removal in the interproximal area of teeth 21 and 22 in addition to root coverage of the affected area through two surgical phases: keratinized gingival tissue augmentation surgery with free gingival graft concurrent with removal of the lesion and, in a second stage, root coverage by performing coronally advanced flap technique with a follow-up of five years. The initial results achieved, which were root coverage of 100% after 6 months, promoted an adequate gingival contour and prevented the development of a mucogingival defect or a root exposure with its functional and aesthetic consequences. After five years, the results showed long term success of the techniques, where the margin remained stable with complete root coverage and tissues were stable and harmonic in color. PMID:27891263

  7. Coverage Root after Removing Peripheral Ossifying Fibroma: 5-Year Follow-Up Case Report.

    PubMed

    Henriques, Paulo S G; Okajima, Luciana S; Nunes, Marcelo P; Montalli, Victor A M

    2016-01-01

    When lesions in soft tissue reach the gingival margin, they can produce aesthetic defects during its permanence and after its removal. Periodontal plastic surgery allows the correction of the gingival contour using different techniques. This paper is a case report of a peripheral ossifying fibroma removal in the interproximal area of teeth 21 and 22 in addition to root coverage of the affected area through two surgical phases: keratinized gingival tissue augmentation surgery with free gingival graft concurrent with removal of the lesion and, in a second stage, root coverage by performing coronally advanced flap technique with a follow-up of five years. The initial results achieved, which were root coverage of 100% after 6 months, promoted an adequate gingival contour and prevented the development of a mucogingival defect or a root exposure with its functional and aesthetic consequences. After five years, the results showed long term success of the techniques, where the margin remained stable with complete root coverage and tissues were stable and harmonic in color.

  8. Mumps Outbreak at a University and Recommendation for a Third Dose of Measles-Mumps-Rubella Vaccine - Illinois, 2015-2016.

    PubMed

    Albertson, Justin P; Clegg, Whitney J; Reid, Heather D; Arbise, Benjamin S; Pryde, Julie; Vaid, Awais; Thompson-Brown, Rachella; Echols, Fredrick

    2016-07-29

    Mumps is an acute viral disease characterized by fever and swelling of the parotid or other salivary glands. On May 1, 2015, the Illinois Department of Public Health (IDPH) confirmed a mumps outbreak at the University of Illinois at Urbana-Champaign. IDPH and the Champaign-Urbana Public Health District (C-UPHD) conducted an investigation and identified 317 cases of mumps during April 2015-May 2016. Because of sustained transmission in a population with high 2-dose coverage with measles-mumps-rubella (MMR) vaccine, a third MMR dose was recommended by IDPH, C-UPHD, and the university's McKinley Health Center. No formal recommendation for or against the use of a third MMR dose has been issued by the Advisory Committee on Immunization Practices (ACIP) (1). However, CDC has provided guidelines for use of a third dose as a control measure during mumps outbreaks in settings in which persons are in close contact with one another, where transmission is sustained despite high 2-dose MMR coverage, and when traditional control measures fail to slow transmission (2).

  9. Rural water supply and sanitation (RWSS) coverage in Swaziland: Toward achieving millennium development goals

    NASA Astrophysics Data System (ADS)

    Mwendera, E. J.

    An assessment of rural water supply and sanitation (RWSS) coverage in Swaziland was conducted in 2004/2005 as part of the Rural Water Supply and Sanitation Initiative (RWSSI). The initiative was developed by the African Development Bank with the aim of implementing it in the Regional Member Countries (RMCs), including Swaziland. Information on the RWSS sector programmes, costs, financial requirements and other related activities was obtained from a wide range of national documents, including sector papers and project files and progress reports. Interviews were held with staff from the central offices and field stations of Government of Swaziland (GOS) ministries and departments, non-governmental organizations (NGOs), bilateral and multilateral external support agencies, and private sector individuals and firms with some connection to the sector and/or its programmes. The assessment also involved field visits to various regions in order to obtain first hand information about the various technologies and institutional structures used in the provision of water supplies and sanitation services in the rural areas of the country. The results showed that the RWSS sector has made significant progress towards meeting the national targets of providing water and sanitation to the entire rural population by the year 2022. The assessment indicated that rural water supply coverage was 56% in 2004 while sanitation coverage was 63% in the same year. The results showed that there is some decline in the incidence of water-related diseases, such as diarrhoeal diseases, probably due to improved water supply and sanitation coverage. The study also showed that, with adequate financial resources, Swaziland is likely to achieve 100% coverage of both water supply and sanitation by the year 2022. It was concluded that in achieving its own national goals Swaziland will exceed the Millennium Development Goals (MDGs). However, such achievement is subject to adequate financial resources being made available for the RWSS sector.

  10. Vaccination coverage and factors influencing routine vaccination status in 12 high risk health zones in the Province of Kinshasa City, Democratic Republic of Congo (DRC), 2015.

    PubMed

    Mwamba, Guillaume Ngoie; Yoloyolo, Norbert; Masembe, Yolande; Nsambu, Muriel Nzazi; Nzuzi, Cathy; Tshekoya, Patrice; Dah, Barthelemy; Kaya, Guylain

    2017-01-01

    Vaccination coverage of the first dose of diphtheria-tetanus-pertussis-hepatitis B- Haemophilus influenza type b (pentavalent) vaccine for the City-Province of Kinshasain the years 2012 - 2014 wasbelow the national objective of 92%, with coverage less than 80% reported in 12 of the 35 health zones (HZ). The purpose of this study was to discern potential contributing factors to low vaccination coverage in Kinshasa. We conducted a multi-stage cluster household study of children 6 - 11 months in households residing in their current neighborhood for at least 3 months in the 12 high risk HZ in Kinshasa. Additional information on vaccination status of the children was collected at the health facility. Of the 1,513 households with a child 6-11 months old, 81% were eligible and participated. Among the 1224 children surveyed, 96% had received the first dose of pentavalent vaccine; 84% had received the third dose; and 71% had received all recommended vaccines for their age. Longer travel time to get to health facility (p=0.04) and shorter length of residence in the neighborhood (p=0.04) showed significant differences in relation to incomplete vaccination. Forty percent of children received their most recent vaccination in a facility outside of their HZ of residence. This survey found vaccination coverage in 12 HZs in Kinshasa was higher than estimates derived from administrative reports. The large percentage of children vaccinated outside of their HZ of residence demonstrates the challenge to use of the Reaching Every District strategy in urban areas.

  11. Human Papillomavirus Vaccination Uptake before and after the Affordable Care Act: Variation According to Insurance Status, Race, and Education (NHANES 2006-2014).

    PubMed

    Corriero, Rosemary; Gay, Jennifer L; Robb, Sara Wagner; Stowe, Ellen W

    2018-02-01

    The purpose of the study was to compare human papillomavirus (HPV) vaccination rates before and after Affordable Care Act (ACA) implementation among women, and examine differences according to insurance status and other sociodemographic variables. This was a cross-sectional analysis of the National Health and Nutrition Examination Survey questionnaire data. Participants (n = 4599) were from a random sample of the United States population. HPV vaccination status and number of doses received according to age, income, education, race, and insurance coverage. Over time, the proportion of women reporting HPV vaccination increased from 16.4% to 27.6%, and reporting vaccination completion (3 doses) increased from 56.8% to 67.2%. After ACA implementation, respondents were 3.3 times more likely to be vaccinated compared with before ACA implementation (95% confidence interval [CI], 2.0-5.5) adjusting for age, race, and insurance coverage. Similarly, respondents were more likely to have received 2 (odds ratio, 2.8; 95% CI, 1.5-5.3) or 3 doses (odds ratio, 5.8; 95% CI, 2.5-13.6). Vaccination uptake increased in a comparison of waves of data from before and after ACA implementation. This increase in vaccination coverage could be related to the increased preventative service coverage, which includes vaccines, required by the ACA. Future studies might focus on the role insurance has on vaccination uptake, and meeting Healthy People 2020 objectives for vaccination coverage. Copyright © 2017 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  12. Radiation Dose Reduction by Indication-Directed Focused z-Direction Coverage for Neck CT.

    PubMed

    Parikh, A K; Shah, C C

    2016-06-01

    The American College of Radiology-American Society of Neuroradiology-Society for Pediatric Radiology Practice Parameter for a neck CT suggests that coverage should be from the sella to the aortic arch. It also recommends using CT scans judiciously to achieve the clinical objective. Our purpose was to analyze the potential dose reduction by decreasing the scan length of a neck CT and to assess for any clinically relevant information that might be missed from this modified approach. This retrospective study included 126 children who underwent a neck CT between August 1, 2013, and September 30, 2014. Alteration of the scan length for the modified CT was suggested on the topographic image on the basis of the indication of the study, with the reader blinded to the images and the report. The CT dose index volume of the original scan was multiplied by the new scan length to calculate the dose-length product of the modified study. The effective dose was calculated for the original and modified studies by using age-based conversion factors from the American Association of Physicists in Medicine Report No. 96. Decreasing the scan length resulted in an average estimated dose reduction of 47%. The average reduction in scan length was 10.4 cm, decreasing the overall coverage by 48%. The change in scan length did not result in any missed findings that altered management. Of the 27 abscesses in this study, none extended to the mediastinum. All of the lesions in question were completely covered. Decreasing the scan length of a neck CT according to the indication provides a significant savings in radiation dose, while not altering diagnostic ability or management. © 2016 by American Journal of Neuroradiology.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, Y; Chang, A; Liu, Y

    Purpose: Electron beams are commonly used for boost radiation following whole breast irradiation (WBI) to improve the in-breast local control. Proton beams have a finite range and a sharper distal dose falloff compared to electron beams, thus potentially sparing more heart and lung in breast treatment. The purpose of the study is to compare protons with electrons for boost breast treatment in terms of target coverage and normal tissue sparing. Methods: Six breast cancer patients were included in this study. All women received WBI to 45–50 Gy, followed by a 10–16.2 Gy boost with standard fractionation. If proton beams weremore » used for the boost treatment, an electron plan was retrospectively generated for comparison using the same CT set and structures, and vice versa if electron beams were used for treatment. Proton plans were generated using the treatment planning system (TPS) with two to three uniform scanning proton beams. Electron plans were generated using the Pinnacle TPS with one single en face beam. Dose-volume histograms (DVH) were calculated and compared between proton and electron boost plans. Results: Proton plans show a similar boost target coverage, similar skin dose, and much better heart and lung sparing. For an example patient, V95% for PTV was 99.98% and skin (5 mm shell) received a max dose close to the prescription dose for both protons and electrons; however, V2 and V5 for the ipsilateral lung and heart were 37.5%, 17.9% and 19.9%, 4.9% respectively for electrons, but were essentially 0 for protons. Conclusions: This dosimetric comparison demonstrates that while both proton therapy and electron therapy provided similar coverage and skin dose, proton therapy could largely reduce the dose to lung and heart, thus leading to potential less side effects.« less

  14. 20 CFR 722.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... States which have in effect a workers' compensation law which provides adequate coverage for death or...' Benefits EMPLOYMENT STANDARDS ADMINISTRATION, DEPARTMENT OF LABOR FEDERAL COAL MINE HEALTH AND SAFETY ACT OF 1969, AS AMENDED CRITERIA FOR DETERMINING WHETHER STATE WORKERS' COMPENSATION LAWS PROVIDE...

  15. The Status of Long-Term Disability Plans in Higher Education.

    ERIC Educational Resources Information Center

    Cook, Thomas J.

    1981-01-01

    Long-term disability income coverage is seen as the most rapidly growing staff benefit in recent years. A Teachers Insurance and Annuity Association's survey of existing long-term disability plans, which provide adequate income replacement, is discussed. (MLW)

  16. TH-CD-209-04: Fuzzy Robust Optimization in Intensity-Modulated Proton Therapy Planning to Account for Range and Patient Setup Uncertainties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    An, Y; Bues, M; Schild, S

    Purpose: We propose to apply a robust optimization model based on fuzzy-logic constraints in the intensity-modulated proton therapy (IMPT) planning subject to range and patient setup uncertainties. The purpose is to ensure the plan robustness under uncertainty and obtain the best trade-off between tumor dose coverage and organ-at-risk(OAR) sparing. Methods: Two IMPT plans were generated for 3 head-and-neck cancer patients: one used the planning target volume(PTV) method; the other used the fuzzy robust optimization method. In the latter method, nine dose distributions were computed - the nominal one and one each for ±3mm setup uncertainties along three cardinal axes andmore » for ±3.5% range uncertainty. For tumors, these nine dose distributions were explicitly controlled by adding hard constraints with adjustable parameters. For OARs, fuzzy constraints that allow the dose to vary within a certain range were used so that the tumor dose distribution was guaranteed by minimum compromise of that of OARs. We rendered this model tractable by converting the fuzzy constraints to linear constraints. The plan quality was evaluated using dose-volume histogram(DVH) indices such as tumor dose coverage(D95%), homogeneity(D5%-D95%), plan robustness(DVH band at D95%), and OAR sparing like D1% of brain and D1% of brainstem. Results: Our model could yield clinically acceptable plans. The fuzzy-logic robust optimization method produced IMPT plans with comparable target dose coverage and homogeneity compared to the PTV method(unit: Gy[RBE]; average[min, max])(CTV D95%: 59 [52.7, 63.5] vs 53.5[46.4, 60.1], CTV D5% - D95%: 11.1[5.3, 18.6] vs 14.4[9.2, 21.5]). It also generated more robust plans(CTV DVH band at D95%: 3.8[1.2, 5.6] vs 11.5[6.2, 16.7]). The parameters of tumor constraints could be adjusted to control the tradeoff between tumor coverage and OAR sparing. Conclusion: The fuzzy-logic robust optimization generates superior IMPT with minimum compromise of OAR sparing. This research was supported by the National Cancer Institute Career Developmental Award K25CA168984, by the Fraternal Order of Eagles Cancer Research Fund Career Development Award, by The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, by Mayo Arizona State University Seed Grant, and by The Kemper Marley Foundation. eRA Person ID(s) for the Principal Investigator: 11017970 (Research Supported by National Institutes of Health)« less

  17. Immunisation coverage annual report, 2011.

    PubMed

    Hull, Brynley P; Dey, Aditi; Menzies, Rob I; Brotherton, Julia M; McIntyre, Peter B

    2013-12-31

    This, the 5th annual immunisation coverage report, documents trends during 2011 for a range of standard measures derived from Australian Childhood Immunisation Register data, and National Human Papillomavirus (HPV) Vaccination Program Register data. The proportion of children 'fully vaccinated' at 12, 24 and 60 months of age was 91.4%, 92.2% and 89.5% respectively. Although pneumococcal vaccine had similar coverage at 12 months to other vaccines, coverage was lower for rotavirus at 12 months (83.8%) and varicella at 24 months (83.9%). By late 2011, the percentage of children who received the 1st dose of DTPa vaccine dose at less than 8 weeks of age was greater than 50% in 3 jurisdictions, the Australian Capital Territory, Victoria, and Queensland and at 70% for New South Wales and Tasmania. Although coverage at 12 months of age was lower among Indigenous children than non-Indigenous children in all jurisdictions, the extent of the difference varied. Overall, coverage at 24 months of age exceeded that at 12 months of age nationally. At 60 months of age, there was dramatic variation between individual jurisdictions, ranging from coverage 8% lower in Indigenous children in South Australia to 6% higher in the Northern Territory. As previously documented, vaccines recommended for Indigenous children only (hepatitis A and pneumococcal polysaccharide vaccine) had suboptimal coverage at 60% and 68%, respectively. On-time receipt (before 49 months of age) of vaccines by Indigenous children at the 60-month milestone age improved between 2010 (18%) and 2011 (19%) but the disparity in on-time vaccination between Indigenous and non-Indigenous children increased at all 3 age milestones. The percentage of vaccine objectors in 2011 (1.7%) has increased from 2007 when it was 1.1%. Coverage data for the 3rd dose of HPV from the national HPV register in the school catch up program was 71% but was substantially lower for the catch-up program for women outside school (39%-67%), although this was an improvement from 2010. This work is copyright. Apart from any use as permitted under the Copyright Act 1968, no part may be reproduced by any process without prior written permission from the Commonwealth. Requests and inquiries concerning reproduction and rights should be addressed to the Commonwealth Copyright Administration, Attorney General's Department, Robert Garran Offices, National Circuit, Barton ACT 2600 or posted at http://www.ag.gov.au/cca.

  18. Coverage and cost of a large oral cholera vaccination program in a high-risk cholera endemic urban population in Dhaka, Bangladesh.

    PubMed

    Khan, Iqbal Ansary; Saha, Amit; Chowdhury, Fahima; Khan, Ashraful Islam; Uddin, Md Jasim; Begum, Yasmin A; Riaz, Baizid Khoorshid; Islam, Sanjida; Ali, Mohammad; Luby, Stephen P; Clemens, John D; Cravioto, Alejandro; Qadri, Firdausi

    2013-12-09

    A feasibility study of an oral cholera vaccine was carried out to test strategies to reach high-risk populations in urban Mirpur, Dhaka, Bangladesh. The study was cluster randomized, with three arms: vaccine, vaccine plus safe water and hand washing practice, and no intervention. High risk people of age one year and above (except pregnant woman) from the two intervention arms received two doses of the oral cholera vaccine, Shanchol™. Vaccination was conducted between 17th February and 16th April 2011, with a minimum interval of fourteen days between two doses. Interpersonal communication preceded vaccination to raise awareness amongst the target population. The number of vaccine doses used, the population vaccinated, left-out, drop out, vaccine wastage and resources required were documented. Fixed outreach site vaccination strategy was adopted as the mode of vaccine delivery. Additionally, mobile vaccination sites and mop-up activities were carried out to reach the target communities. Of the 172,754 target population, 141,839 (82%) and 123,666 (72%) received complete first and second doses of the vaccine, respectively. Dropout rate from the first to the second dose was 13%. Two complete doses were received by 123,661 participants. Vaccine coverage in children was 81%. Coverage was significantly higher in females than in males (77% vs. 66%, P<0.001). Vaccine wastage for delivering the complete doses was 1.2%. The government provided cold-chain related support at no cost to the project. Costs for two doses of vaccine per-person were US$3.93, of which US$1.63 was spent on delivery. Cost for delivering a single dose was US$0.76. We observed no serious adverse events. Mass vaccination with oral cholera vaccine is feasible for reaching high risk endemic population through the existing national immunization delivery system employed by the government. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Seasonal influenza vaccine dose distribution in 157 countries (2004-2011).

    PubMed

    Palache, Abraham; Oriol-Mathieu, Valerie; Abelin, Atika; Music, Tamara

    2014-11-12

    Globally there are an estimated 3-5 million cases of severe influenza illness every year, resulting in 250,000-500,000 deaths. At the World Health Assembly in 2003, World Health Organization (WHO) resolved to increase influenza vaccine coverage rates (VCR) for high-risk groups, particularly focusing on at least 75% of the elderly by 2010. But systematic worldwide data have not been available to assist public health authorities to monitor vaccine uptake and review progress toward vaccination coverage targets. In 2008, the International Federation of Pharmaceutical Manufacturers and Associations Influenza Vaccine Supply task force (IFPMA IVS) developed a survey methodology to assess global influenza vaccine dose distribution. The current survey results represent 2011 data and demonstrate the evolution of the absolute number distributed between 2004 and 2011 inclusive, and the evolution in the per capita doses distributed in 2008-2011. Global distribution of IFPMA IVS member doses increased approximately 86.9% between 2004 and 2011, but only approximately 12.1% between 2008 and 2011. The WHO's regions in Eastern Mediterranean (EMRO), Southeast Asian (SEARO) and Africa (AFRO) together account for about 47% of the global population, but only 3.7% of all IFPMA IVS doses distributed. While distributed doses have globally increased, they have decreased in EURO and EMRO since 2009. Dose distribution can provide a reasonable proxy of vaccine utilization. Based on the dose distribution, we conclude that seasonal influenza VCR in many countries remains well below the WHA's VCR targets and below the recommendations of the Council of the European Union in EURO. Inter- and intra-regional disparities in dose distribution trends call into question the impact of current vaccine recommendations at achieving coverage targets. Additional policy measures, particularly those that influence patients adherence to vaccination programs, such as reimbursement, healthcare provider knowledge, attitudes, practices, and communications, are required for VCR targets to be met and benefit public health. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Fetal radiation monitoring and dose minimization during intensity modulated radiation therapy for glioblastoma in pregnancy.

    PubMed

    Horowitz, David P; Wang, Tony J C; Wuu, Cheng-Shie; Feng, Wenzheng; Drassinower, Daphnie; Lasala, Anita; Pieniazek, Radoslaw; Cheng, Simon; Connolly, Eileen P; Lassman, Andrew B

    2014-11-01

    We examined the fetal dose from irradiation of glioblastoma during pregnancy using intensity modulated radiation therapy (IMRT), and describe fetal dose minimization using mobile shielding devices. A case report is described of a pregnant woman with glioblastoma who was treated during the third trimester of gestation with 60 Gy of radiation delivered via a 6 MV photon IMRT plan. Fetal dose without shielding was estimated using an anthropomorphic phantom with ion chamber and diode measurements. Clinical fetal dose with shielding was determined with optically stimulated luminescent dosimeters and ion chamber. Clinical target volume (CTV) and planning target volume (PTV) coverage was 100 and 98 % receiving 95 % of the prescription dose, respectively. Normal tissue tolerances were kept below quantitative analysis of normal tissue effects in the clinic (QUANTEC) recommendations. Without shielding, anthropomorphic phantom measurements showed a cumulative fetal dose of 0.024 Gy. In vivo measurements with shielding in place demonstrated a cumulative fetal dose of 0.016 Gy. The fetal dose estimated without shielding was 0.04 % and with shielding was 0.026 % of the target dose. In vivo estimation of dose equivalent received by the fetus was 24.21 mSv. Using modern techniques, brain irradiation can be delivered to pregnant patients in the third trimester with very low measured doses to the fetus, without compromising target coverage or normal tissue dose constraints. Fetal dose can further be reduced with the use of shielding devices, in keeping with the principle of as low as reasonably achievable.

  1. Can Turkey's general health insurance system achieve universal coverage?

    PubMed

    Yasar, Gulbiye Yenimahalleli; Ugurluoglu, Ece

    2011-01-01

    This study aims to evaluate the General Health Insurance System (GHIS) in Turkey implemented since 1 October 2008, in order to assess whether the GHIS will be able to achieve its objective of universal coverage. Both the breadth and depth of coverage will be taken into account. The study notes out that some socio-economic problems, such as a significant informal economy, high unemployment rate, inefficiency in the creation of adequate employment opportunities, inequitable income distribution, and widespread poverty, are the main problems preventing the GHIS from reaching breadth of coverage in Turkey. Contribution conditions for entitlement to health services prevent the GHIS from providing breadth of coverage too. Outof- pocket payments, which are higher than in European and OECD countries, narrow the depth of coverage, but the GHIS brings additional user fees. Statistics show that despite its objective, the GHIS struggles to provide universal coverage. It seems the GHIS will not be able to provide universal coverage in the near future because of the socio-economic conditions and conditions for entitlement to health services. In this case the government will either introduce radical arrangements to cope with the socio-economic problems and issues with the funding system or should consider switching from an insurance-based system towards a tax-based system.

  2. The epidemiology of rabies in Zimbabwe. 1. Rabies in dogs (Canis familiaris).

    PubMed

    Bingham, J; Foggin, C M; Wandeler, A I; Hill, F W

    1999-03-01

    The epidemiology of rabies in dogs in Zimbabwe is described using data from 1950, when rabies was re-introduced after a 37-year absence, to 1996. Dogs constituted 45.7% of all laboratory-confirmed rabies cases and were the species most frequently diagnosed with the disease. Slightly more cases were diagnosed from June to November than in other months. From 1950 to the early 1980s, most dog cases were recorded from commercial farming areas, but since the early 1980s most have been recorded from communal (subsistence farming) areas. This change appears to be due to improved surveillance in communal areas and not to any change in the prevalence of rabies. Dog rabies therefore appears to be maintained mainly in communal area dog populations, particularly the large communal area blocks. Urban rabies was not important except in the city of Mutare. Where dog rabies prevalence was high, the disease was cyclic with periods between peak prevalence ranging from 4-7 years. Dog rabies cases were, on the whole, independent of jackal rabies and rabies in other carnivores. There was a significant negative relationship between the annual number of rabies vaccine doses administered nationally to dogs and the annual number of dog rabies cases lagged by one year, indicating that the past levels of immunisation coverage have had a significant effect on the number of rabies cases. However, dog vaccination coverage has clearly not been adequate to prevent the regular occurrence of rabies in dogs.

  3. Definition of the supraclavicular and infraclavicular nodes: implications for three-dimensional CT-based conformal radiation therapy.

    PubMed

    Madu, C N; Quint, D J; Normolle, D P; Marsh, R B; Wang, E Y; Pierce, L J

    2001-11-01

    To delineate with computed tomography (CT) the anatomic regions containing the supraclavicular (SCV) and infraclavicular (IFV) nodal groups, to define the course of the brachial plexus, to estimate the actual radiation dose received by these regions in a series of patients treated in the traditional manner, and to compare these doses to those received with an optimized dosimetric technique. Twenty patients underwent contrast material-enhanced CT for the purpose of radiation therapy planning. CT scans were used to study the location of the SCV and IFV nodal regions by using outlining of readily identifiable anatomic structures that define the nodal groups. The brachial plexus was also outlined by using similar methods. Radiation therapy doses to the SCV and IFV were then estimated by using traditional dose calculations and optimized planning. A repeated measures analysis of covariance was used to compare the SCV and IFV depths and to compare the doses achieved with the traditional and optimized methods. Coverage by the 90% isodose surface was significantly decreased with traditional planning versus conformal planning as the depth to the SCV nodes increased (P < .001). Significantly decreased coverage by using the 90% isodose surface was demonstrated for traditional planning versus conformal planning with increasing IFV depth (P = .015). A linear correlation was found between brachial plexus depth and SCV depth up to 7 cm. Conformal optimized planning provided improved dosimetric coverage compared with standard techniques.

  4. Multi-Body Orbit Architectures for Lunar South Pole Coverage

    NASA Technical Reports Server (NTRS)

    Grebow, D. J.; Ozimek, M. T.; Howell, K. C.; Folta, D. C.

    2006-01-01

    A potential ground station at the lunar south pole has prompted studies of orbit architectures that ensure adequate coverage. Constant communications can be achieved with two spacecraft in different combinations of Earth-Moon libration point orbits. Halo and vertical families, as well as other orbits near L1 and L2 are considered. The investigation includes detailed results using nine different orbits with periods ranging from 7 to 16 days. Natural solutions are generated in a full ephemeris model, including solar perturbations. A preliminary station-keeping analysis is also completed.

  5. Mixing weld gases offers advantages

    NASA Technical Reports Server (NTRS)

    May, J. L.; Mendenhall, M. M.

    1969-01-01

    Argon added to helium during gas tungsten arc cover-pass welding in the horizontal position results in a better controlled wider bead width, increased arc stability, and reduction in heat input. Adequate filler material wetness and penetration pass coverage is possible with only one pass.

  6. Standard dosing of amikacin and gentamicin in critically ill patients results in variable and subtherapeutic concentrations.

    PubMed

    Roger, Claire; Nucci, Bastian; Molinari, Nicolas; Bastide, Sophie; Saissi, Gilbert; Pradel, Gael; Barbar, Saber; Aubert, Clément; Lloret, Sophie; Elotmani, Loubna; Polge, Anne; Lefrant, Jean-Yves; Roberts, Jason A; Muller, Laurent

    2015-07-01

    Low peak plasma concentrations (Cmax) of amikacin and gentamicin are reported in intensive care unit (ICU) patients after administration of the first dose. The present study aimed to describe the proportion of ICU patients in whom an adequate Cmax was achieved throughout the course of therapy. Septic ICU patients with an indication for intravenous amikacin or gentamicin were eligible for inclusion in this single-centre observational study. The first and subsequent doses and the corresponding Cmax values were recorded. The target Cmax was ≥60mg/L for amikacin and ≥30mg/L for gentamicin. Amikacin and gentamicin plasma concentrations were available in 66 and 24 patients, respectively (59±17 years; 79±19kg; height 169±12cm; SAPS II score 46±19). Pulmonary, abdominal and urinary tract infections were diagnosed in 64 patients. Culture-positive infection was confirmed in 65 patients (72%). A target first Cmax was achieved in 17/90 patients (19%). For amikacin, the target Cmax was achieved in 16/66 patients (24%) after the initial dose. In the 50 remaining patients, a change in dosing was performed in 14 patients, leading adequate peak plasma level in 2 patients. For gentamicin, the targeted Cmax was achieved in only 1/24 patient (4%) after the initial dose and was never achieved after the third dose. In conclusion, standard dosing of amikacin or gentamicin led to adequate Cmax in only 19% of patients. Subtherapeutic Cmax were not significantly corrected after subsequent doses. Copyright © 2015 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.

  7. Characteristics of coordinated ongoing comprehensive care within a medical home in Maine.

    PubMed

    Tippy, Kathy; Meyer, Katie; Aronson, Richard; Wall, Toni

    2005-06-01

    Access to coordinated, ongoing comprehensive care in a medical home (CCMH) is a national health objective and a federal performance measure. The National Survey of Children With Special Health Care Needs (National Survey of CSHCN) provides state level data on this Maternal Child Health Bureau performance measure. In Maine, only 60% of CSHCN received CCMH in 2001. Here we described characteristics of receiving comprehensive care in a medical home for CSHCN, in Maine. Data from the National Survey of CSHCN were used for the analysis. We examined associations between receiving CCMH and demographic factors, severity of a condition or problem, and having adequate insurance coverage for services in univariate and multivariate logistic regression models. The distribution of children who received CCMH did not differ across gender, race, age, or poverty level. Children with adequate insurance were more likely to have received this care than those without adequate insurance and those with a more severe condition or problem were less likely to receive CCMH. We found that receiving CCMH was positively related to adequate insurance, independent of poverty. We also found that CSHCN with more severe conditions have more unmet needs than those with less severe conditions. CSHCN programs, which have a responsibility to assure that CSHCN receive CCMH, must work to maximize insurance coverage. Programs can also work to raise awareness among providers of the complexity of CCMH and the role it plays in maximizing the health of the child and family.

  8. A way to improve dose rate laser simulation adequacy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Skorobogatov, P.K.; Nikiforov, A.Y.; Demidov, A.A.

    1998-12-01

    A method for improving laser simulation of dose rate radiation in silicon IC`s (Integrated Circuit) is analyzed based on the application of noncoherent laser radiation. Experimental validation was performed using test structures with up to 90% surface metallization coverage.

  9. SU-E-T-622: Planning Technique for Passively-Scattered Involved-Node Proton Therapy of Mediastinal Lymphoma with Consideration of Cardiac Motion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flampouri, S; Li, Z; Hoppe, B

    2015-06-15

    Purpose: To develop a treatment planning method for passively-scattered involved-node proton therapy of mediastinal lymphoma robust to breathing and cardiac motions. Methods: Beam-specific planning treatment volumes (bsPTV) are calculated for each proton field to incorporate pertinent uncertainties. Geometric margins are added laterally to each beam while margins for range uncertainty due to setup errors, breathing, and calibration curve uncertainties are added along each beam. The calculation of breathing motion and deformation effects on proton range includes all 4DCT phases. The anisotropic water equivalent margins are translated to distances on average 4DCT. Treatment plans are designed so each beam adequately coversmore » the corresponding bsPTV. For targets close to the heart, cardiac motion effects on dosemaps are estimated by using a library of anonymous ECG-gated cardiac CTs (cCT). The cCT, originally contrast-enhanced, are partially overridden to allow meaningful proton dose calculations. Targets similar to the treatment targets are drawn on one or more cCT sets matching the anatomy of the patient. Plans based on the average cCT are calculated on individual phases, then deformed to the average and accumulated. When clinically significant dose discrepancies occur between planned and accumulated doses, the patient plan is modified to reduce the cardiac motion effects. Results: We found that bsPTVs as planning targets create dose distributions similar to the conventional proton planning distributions, while they are a valuable tool for visualization of the uncertainties. For large targets with variability in motion and depth, integral dose was reduced because of the anisotropic margins. In most cases, heart motion has a clinically insignificant effect on target coverage. Conclusion: A treatment planning method was developed and used for proton therapy of mediastinal lymphoma. The technique incorporates bsPTVs compensating for all common sources of uncertainties and estimation of the effects of cardiac motion not commonly performed.« less

  10. Evaluation and mitigation of the interplay effects for intensity modulated proton therapy for lung cancer in a clinical setting

    PubMed Central

    Kardar, Laleh; Li, Yupeng; Li, Xiaoqiang; Li, Heng; Cao, Wenhua; Chang, Joe Y.; Liao, Li; Zhu, Ronald X.; Sahoo, Narayan; Gillin, Michael; Liao, Zhongxing; Komaki, Ritsuko; Cox, James D.; Lim, Gino; Zhang, Xiaodong

    2015-01-01

    Purpose The primary aim of this study was to evaluate the impact of interplay effects for intensity-modulated proton therapy (IMPT) plans for lung cancer in the clinical setting. The secondary aim was to explore the technique of iso-layered re-scanning for mitigating these interplay effects. Methods and Materials Single-fraction 4D dynamic dose without considering re-scanning (1FX dynamic dose) was used as a metric to determine the magnitude of dosimetric degradation caused by 4D interplay effects. The 1FX dynamic dose was calculated by simulating the machine delivery processes of proton spot scanning on moving patient described by 4D computed tomography (4DCT) during the IMPT delivery. The dose contributed from an individual spot was fully calculated on the respiratory phase corresponding to the life span of that spot, and the final dose was accumulated to a reference CT phase by using deformable image registration. The 1FX dynamic dose was compared with the 4D composite dose. Seven patients with various tumor volumes and motions were selected. Results The CTV prescription coverage for the 7 patients were 95.04%, 95.38%, 95.39%, 95.24%, 95.65%, 95.90%, and 95.53%, calculated with use of the 4D composite dose, and were 89.30%, 94.70%, 85.47%, 94.09%, 79.69%, 91.20%, and 94.19% with use of the 1FX dynamic dose. For the 7 patients, the CTV coverage, calculated by using single-fraction dynamic dose, were 95.52%, 95.32%, 96.36%, 95.28%, 94.32%, 95.53%, and 95.78%, using maximum MU limit value of 0.005. In other words, by increasing the number of delivered spots in each fraction, the degradation of CTV coverage improved up to 14.6%. Conclusions Single-fraction 4D dynamic dose without re-scanning was validated as a surrogate to evaluate the interplay effects for IMPT for lung cancer in the clinical setting. The interplay effects can be potentially mitigated by increasing the number of iso-layered re-scanning in each fraction delivery. PMID:25407877

  11. Evaluation and mitigation of the interplay effects of intensity modulated proton therapy for lung cancer in a clinical setting.

    PubMed

    Kardar, Laleh; Li, Yupeng; Li, Xiaoqiang; Li, Heng; Cao, Wenhua; Chang, Joe Y; Liao, Li; Zhu, Ronald X; Sahoo, Narayan; Gillin, Michael; Liao, Zhongxing; Komaki, Ritsuko; Cox, James D; Lim, Gino; Zhang, Xiaodong

    2014-01-01

    The primary aim of this study was to evaluate the impact of the interplay effects of intensity modulated proton therapy (IMPT) plans for lung cancer in the clinical setting. The secondary aim was to explore the technique of isolayered rescanning to mitigate these interplay effects. A single-fraction 4-dimensional (4D) dynamic dose without considering rescanning (1FX dynamic dose) was used as a metric to determine the magnitude of dosimetric degradation caused by 4D interplay effects. The 1FX dynamic dose was calculated by simulating the machine delivery processes of proton spot scanning on a moving patient, described by 4D computed tomography during IMPT delivery. The dose contributed from an individual spot was fully calculated on the respiratory phase that corresponded to the life span of that spot, and the final dose was accumulated to a reference computed tomography phase by use of deformable image registration. The 1FX dynamic dose was compared with the 4D composite dose. Seven patients with various tumor volumes and motions were selected for study. The clinical target volume (CTV) prescription coverage for the 7 patients was 95.04%, 95.38%, 95.39%, 95.24%, 95.65%, 95.90%, and 95.53% when calculated with the 4D composite dose and 89.30%, 94.70%, 85.47%, 94.09%, 79.69%, 91.20%, and 94.19% when calculated with the 1FX dynamic dose. For these 7 patients, the CTV coverage calculated by use of a single-fraction dynamic dose was 95.52%, 95.32%, 96.36%, 95.28%, 94.32%, 95.53%, and 95.78%, with a maximum monitor unit limit value of 0.005. In other words, by increasing the number of delivered spots in each fraction, the degradation of CTV coverage improved up to 14.6%. A single-fraction 4D dynamic dose without rescanning was validated as a surrogate to evaluate the interplay effects of IMPT for lung cancer in the clinical setting. The interplay effects potentially can be mitigated by increasing the amount of isolayered rescanning in each fraction delivery.

  12. Human Papillomavirus Vaccination Coverage Among Girls Before 13 Years: A Birth Year Cohort Analysis of the National Immunization Survey-Teen, 2008-2013.

    PubMed

    Jeyarajah, Jenny; Elam-Evans, Laurie D; Stokley, Shannon; Smith, Philip J; Singleton, James A

    2016-09-01

    Routine human papillomavirus (HPV) vaccination is recommended at 11 or 12 years by the Advisory Committee on Immunization Practices. National Immunization Survey-Teen data were analyzed to evaluate, among girls, coverage with one or more doses of HPV vaccination, missed opportunities for HPV vaccination, and potential achievable coverage before 13 years. Results were stratified by birth year cohorts. HPV vaccination coverage before 13 years (≥1 HPV dose) increased from 28.4% for girls born in 1995 to 46.8% for girls born in 2000. Among girls born during 1999-2000 who had not received HPV vaccination before 13 years (57.2%), 80.1% had at least 1 missed opportunity to receive HPV vaccination before 13 years. Opportunities to vaccinate for HPV at age 11 to 12 years are missed. Strategies are needed to decrease these missed opportunities for HPV vaccination. This can be facilitated by the administration of all vaccines recommended for adolescents at the same visit. © The Author(s) 2015.

  13. Pharmacokinetics and Target Attainment of Ceftobiprole in Asian and Non-Asian Subjects.

    PubMed

    Muller, A E; Punt, N; Engelhardt, M; Schmitt-Hoffmann, A H; Mouton, J W

    2018-05-16

    Ceftobiprole is a broad-spectrum cephalosporin. The objective of this study was to test the hypothesis that the pharmacokinetics (PK) and exposure of ceftobiprole in Asian subjects are similar to those in non-Asian subjects. Three approaches were followed. The first compared the individual PK estimates between the 2 subgroups derived from a population PK model previously built. Next, it was determined whether "Asian subject" was a significant covariate. Finally, a pharmacodynamic analysis was performed by comparing measures of exposure and target attainment. No significant differences were found between PK parameter estimates for Asian and non-Asian subjects, with median values (range) for clearance of 4.82 L/h (2.12-10.47) and 4.97 L/h (0.493-20.6), respectively (P = .736). "Asian subject" was not a significant covariate in the population PK model. There were no significant differences between the measures of exposure. The geometric mean ratio for the fAUC was 1.022 (90%CI, 0.91-1.15), indicating bioequivalence. Taking a target of 60% coverage of the dose interval, more than 90% of the population in both subgroups was adequately exposed. This analysis demonstrated that there are no PK or pharmacodynamic differences between Asian and non-Asian subjects for a ceftobiprole dose of 500 mg every 8 hours as a 2-hour infusion. © 2018, The American College of Clinical Pharmacology.

  14. Vaccination coverage and its determinants among migrant children in Guangdong, China

    PubMed Central

    2014-01-01

    Background Guangdong province attracted more than 31 million migrants in 2010. But few studies were performed to estimate the complete and age-appropriate immunization coverage and determine risk factors of migrant children. Methods 1610 migrant children aged 12–59 months from 70 villages were interviewed in Guangdong. Demographic characteristics, primary caregiver’s knowledge and attitude toward immunization, and child’s immunization history were obtained. UTD and age-appropriate immunization rates for the following five vaccines and the overall series (1:3:3:3:1 immunization series) were assessed: one dose of BCG, three doses of DTP, OPV and HepB, one dose of MCV. Risk factors for not being UTD for the 1:3:3:3:1 immunization series were explored. Results For each antigen, the UTD immunization rate was above 71%, but the age-appropriate immunization rates for BCG, HepB, OPV, DPT and MCV were only 47.8%, 45.1%, 47.1%, 46.8% and 37.2%, respectively. The 1st dose was most likely to be delayed within them. For the 1:3:3:3:1 immunization series, the UTD immunization rate and age-appropriate immunization rate were 64.9% and 12.4% respectively. Several factors as below were significantly associated with UTD immunization. The primary caregiver’s determinants were their occupation, knowledge and attitude toward immunization. The child’s determinants were sex, Hukou, birth place, residential buildings and family income. Conclusions Alarmingly low immunization coverage of migrant children should be closely monitored by NIISS. Primary caregiver and child’s determinants should be considered when taking measures. Strategies to strengthen active out-reach activities and health education for primary caregivers needed to be developed to improve their immunization coverage. PMID:24568184

  15. Local discrepancies in measles vaccination opportunities: results of population-based surveys in Sub-Saharan Africa

    PubMed Central

    2014-01-01

    Background The World Health Organization recommends African children receive two doses of measles containing vaccine (MCV) through routine programs or supplemental immunization activities (SIA). Moreover, children have an additional opportunity to receive MCV through outbreak response immunization (ORI) mass campaigns in certain contexts. Here, we present the results of MCV coverage by dose estimated through surveys conducted after outbreak response in diverse settings in Sub-Saharan Africa. Methods We included 24 household-based surveys conducted in six countries after a non-selective mass vaccination campaign. In the majority (22/24), the survey sample was selected using probability proportional to size cluster-based sampling. Others used Lot Quality Assurance Sampling. Results In total, data were collected on 60,895 children from 2005 to 2011. Routine coverage varied between countries (>95% in Malawi and Kirundo province (Burundi) while <35% in N’Djamena (Chad) in 2005), within a country and over time. SIA coverage was <75% in most settings. ORI coverage ranged from >95% in Malawi to 71.4% [95% CI: 68.9-73.8] in N’Djamena (Chad) in 2005. In five sites, >5% of children remained unvaccinated after several opportunities. Conversely, in Malawi and DRC, over half of the children eligible for the last SIA received a third dose of MCV. Conclusions Control pre-elimination targets were still not reached, contributing to the occurrence of repeated measles outbreak in the Sub-Saharan African countries reported here. Although children receiving a dose of MCV through outbreak response benefit from the intervention, ensuring that programs effectively target hard to reach children remains the cornerstone of measles control. PMID:24559281

  16. Trends in Childhood Influenza Vaccination Coverage—U.S., 2004–2012

    PubMed Central

    Lu, Peng-Jun; O'Halloran, Alissa; Meghani, Ankita; Grabowsky, Mark; Singleton, James A.

    2014-01-01

    Objective We compared estimates of childhood influenza vaccination coverage by health status, age, and racial/ethnic group across eight consecutive influenza seasons (2004 through 2012) based on two survey systems to assess trends in childhood influenza vaccination coverage in the U.S. Methods We used National Health Interview Survey (NHIS) and National Immunization Survey-Flu (NIS-Flu) data to estimate receipt of at least one dose of influenza vaccination among children aged 6 months to 17 years based on parental report. We computed estimates using Kaplan-Meier survival analysis methods. Results Based on the NHIS, overall influenza vaccination coverage with at least one dose of influenza vaccine among children increased from 16.2% during the 2004–2005 influenza season to 47.1% during the 2011–2012 influenza season. Children with health conditions that put them at high risk for complications from influenza had higher influenza vaccination coverage than children without these health conditions for all the seasons studied. In seven of the eight seasons studied, there were no significant differences in influenza vaccination coverage between non-Hispanic black and non-Hispanic white children. Influenza vaccination coverage estimates for children were slightly higher based on NIS-Flu data compared with NHIS data for the 2010–2011 and 2011–2012 influenza seasons (4.1 and 4.4 percentage points higher, respectively); both NIS-Flu and NHIS estimates had similar patterns of decreasing vaccination coverage with increasing age. Conclusions Although influenza vaccination coverage among children continued to increase, by the 2011–2012 influenza season, only slightly less than half of U.S. children were vaccinated against influenza. Much improvement is needed to ensure all children aged ≥6 months are vaccinated annually against influenza. PMID:25177053

  17. Repeated sugammadex reversal of muscle relaxation during lumbar spine surgery with intraoperative neurophysiological multimodal monitoring.

    PubMed

    Errando, C L; Blanco, T; Díaz-Cambronero, Ó

    2016-11-01

    Intraoperative neurophysiological monitoring during spine surgery is usually acomplished avoiding muscle relaxants. A case of intraoperative sugammadex partial reversal of the neuromuscular blockade allowing adequate monitoring during spine surgery is presented. A 38 year-old man was scheduled for discectomy and vertebral arthrodesis throughout anterior and posterior approaches. Anesthesia consisted of total intravenous anesthesia plus rocuronium. Intraoperatively monitoring was needed, and the muscle relaxant reverted twice with low dose sugammadex in order to obtain adequate responses. The doses of sugammadex used were conservatively selected (0.1mg/kg boluses increases, total dose needed 0.4mg/kg). Both motor evoqued potentials, and electromyographic responses were deemed adequate by the neurophysiologist. If muscle relaxation was needed in the context described, this approach could be useful to prevent neurological sequelae. This is the first study using very low dose sugammadex to reverse rocuronium intraoperatively and to re-establish the neuromuscular blockade. Copyright © 2016 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Immunisation status and determinants of left-behind children aged 12-72 months in central China.

    PubMed

    Ni, Z L; Tan, X D; Shao, H Y; Wang, Y

    2017-07-01

    Many parents move from rural China to urban areas in search of job opportunities, and leave their children behind to be raised by relatives. We aimed to assess the immunisation coverage, including the 1:3:3:3:1 vaccine series (one dose of Bacilli Chalmette-Guérin vaccine; three doses of live attenuated oral poliomyelitis vaccine; three doses of diphtheria, tetanus and pertussis combined; three doses of hepatitis B vaccine; and one dose of measles-containing vaccine), in children aged 12-72 months and identify the determinants of immunisation uptake among left-behind children in Hubei Province, Central China, in 2014. In this cross-sectional study using the World Health Organization's cluster sampling technique, we surveyed 1368 children from 44 villages in 11 districts of Hubei Province. The socio-demographic and vaccination status data were collected by interviewing primary caregivers using a semi-structured questionnaire and reviewing the immunisation cards of the children. Univariate and multivariate analyses were used to identify the determinants of complete vaccination and age-appropriate vaccination. For each dose of the five vaccines, the vaccination coverage in the left-behind and non-left-behind children was >90%; however, the age-appropriate vaccination coverage for each vaccine was lower in left-behind than in non-left-behind children. For the five vaccines, the fully vaccinated rate of left-behind children were lower than those of non-left-behind children (89·1%, 92·7%; P = 0·013) and age-appropriate immunisation rate of left-behind children were lower than those of non-left-behind children (65·7%, 79·9%; P < 0·001). After controlling for potential confounders, we found that the parenting pattern, annual household income and attitude of the primary caregiver towards vaccination significantly influenced the vaccination status of children. Moreover, we noted a relatively high prevalence of delayed vaccination among left-behind children. Hence, we believe that the age-appropriate immunisation coverage rate among left-behind children in rural areas should be further improved by delivering and sustaining primary care services.

  19. Fully immunized child: coverage, timing and sequencing of routine immunization in an urban poor settlement in Nairobi, Kenya.

    PubMed

    Mutua, Martin Kavao; Kimani-Murage, Elizabeth; Ngomi, Nicholas; Ravn, Henrik; Mwaniki, Peter; Echoka, Elizabeth

    2016-01-01

    More efforts have been put in place to increase full immunization coverage rates in the last decade. Little is known about the levels and consequences of delaying or vaccinating children in different schedules. Vaccine effectiveness depends on the timing of its administration, and it is not optimal if given early, delayed or not given as recommended. Evidence of non-specific effects of vaccines is well documented and could be linked to timing and sequencing of immunization. This paper documents the levels of coverage, timing and sequencing of routine childhood vaccines. The study was conducted between 2007 and 2014 in two informal urban settlements in Nairobi. A total of 3856 children, aged 12-23 months and having a vaccination card seen were included in analysis. Vaccination dates recorded from the cards seen were used to define full immunization coverage, timeliness and sequencing. Proportions, medians and Kaplan-Meier curves were used to assess and describe the levels of full immunization coverage, vaccination delays and sequencing. The findings indicate that 67 % of the children were fully immunized by 12 months of age. Missing measles and third doses of polio and pentavalent vaccine were the main reason for not being fully immunized. Delays were highest for third doses of polio and pentavalent and measles. About 22 % of fully immunized children had vaccines in an out-of-sequence manner with 18 % not receiving pentavalent together with polio vaccine as recommended. Results show higher levels of missed opportunities and low coverage of routine childhood vaccinations given at later ages. New strategies are needed to enable health care providers and parents/guardians to work together to increase the levels of completion of all required vaccinations. In particular, more focus is needed on vaccines given in multiple doses (polio, pentavalent and pneumococcal conjugate vaccines).

  20. Findings from a hepatitis B birth dose assessment in health facilities in the Philippines: opportunities to engage the private sector.

    PubMed

    Patel, Minal K; Capeding, Rosario Z; Ducusin, Joyce U; de Quiroz Castro, Maricel; Garcia, Luzviminda C; Hennessey, Karen

    2014-09-03

    Hepatitis B vaccination in the Philippines was introduced in 1992 to reduce the high burden of chronic hepatitis B virus (HBV) infection in the population; in 2007, a birth dose (HepB-BD) was introduced to decrease perinatal HBV transmission. Timely HepB-BD coverage, defined as doses given within 24h of birth, was 40% nationally in 2011. A first step in improving timely HepB-BD coverage is to ensure that all newborns born in health facilities are vaccinated. In order to assess ways of improving the Philippines' HepB-BD program, we evaluated knowledge, attitudes, and practices surrounding HepB-BD administration in health facilities. Teams visited selected government clinics, government hospitals, and private hospitals in regions with low reported HepB-BD coverage and interviewed immunization and maternity staff. HepB-BD coverage was calculated in each facility for a 3-month period in 2011. Of the 142 health facilities visited, 12 (8%) did not provide HepB-BD; seven were private hospitals and five were government hospitals. Median timely HepB-BD coverage was 90% (IQR 80%-100%) among government clinics, 87% (IQR 50%-97%) among government hospitals, and 50% (IQR 0%-90%) among private hospitals (p=0.02). The private hospitals were least likely to receive supervision (53% vs. 6%-31%, p=0.0005) and to report vaccination data to the national Expanded Programme on Immunization (36% vs. 96%-100%, p<0.0001). Private sector hospitals in the Philippines, which deliver 18% of newborns, had the lowest timely HepB-BD coverage. Multiple avenues exist to engage the private sector in hepatitis B prevention including through existing laws, newborn health initiatives, hospital accreditation processes, and raising awareness of the government's free vaccine program. Copyright © 2013 World Health Organization (WHO). Published by Elsevier Ltd.. All rights reserved.

  1. Evaluation of potentially achievable vaccination coverage of the second dose of measles containing vaccine with simultaneous administration and risk factors for missed opportunities among children in Zhejiang province, east China.

    PubMed

    Hu, Yu; Chen, Yaping; Wang, Ying; Liang, Hui

    2018-04-03

    This study aimed to evaluate the potential achievable coverage of the second dose of measles containing vaccine (MCV2) when the protocol of simultaneous administration of childhood vaccines was fully implemented. Risk factors for missed opportunity (MO) for simultaneous administration of MCV2 were also investigated. Children born from 1 January 2005 to 31 December 2014 and registered in Zhejiang provincial immunization information system were enrolled in this study. The MO of simultaneous administration of MCV2, the actual age-appropriate coverage (AAC) of MCV2 and the potentially achievable coverage (PAC) of MCV2 were evaluated and compared across different birth cohorts, by different socio-demographic variables. For the 2014 birth cohort, logistic regression model was used to detect the risk factors of MOs, from both socio-demographic and vaccination service providing aspects. Compared to the AAC, the PAC of MCV2 increased significantly from 2005 birth cohort to 2014 birth cohort (p<0.001), with a median of 12.7 percentage points. Higher birth order of children, resident children, higher maternal education background, higher socio-economic development level of resident areas, less frequent vaccination service, and shorter vaccination service time were significant risk factors of MO for simultaneous administration of MCV2, with all p-value < 0.05. The findings in this study suggest that fully utilization of all opportunities for simultaneous administration of all age-eligible vaccine doses at the same vaccination visit is critical for achieving the coverage target of 95% for MCV2. Future interventions focusing on the group with risk factors observed could substantially eliminate MOs for simultaneous administration of MCV2, further to improve the coverage of fully immunization of MCV, and finally achieve the goal of eliminating measles.

  2. Generalizable Class Solutions for Treatment Planning of Spinal Stereotactic Body Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weksberg, David C.; Palmer, Matthew B.; Vu, Khoi N.

    2012-11-01

    Purpose: Spinal stereotactic body radiation therapy (SBRT) continues to emerge as an effective therapeutic approach to spinal metastases; however, treatment planning and delivery remain resource intensive at many centers, which may hamper efficient implementation in clinical practice. We sought to develop a generalizable class solution approach for spinal SBRT treatment planning that would allow confidence that a given plan provides optimal target coverage, reduce integral dose, and maximize planning efficiency. Methods and Materials: We examined 91 patients treated with spinal SBRT at our institution. Treatment plans were categorized by lesion location, clinical target volume (CTV) configuration, and dose fractionation scheme,more » and then analyzed to determine the technically achievable dose gradient. A radial cord expansion was subtracted from the CTV to yield a planning CTV (pCTV) construct for plan evaluation. We reviewed the treatment plans with respect to target coverage, dose gradient, integral dose, conformality, and maximum cord dose to select the best plans and develop a set of class solutions. Results: The class solution technique generated plans that maintained target coverage and improved conformality (1.2-fold increase in the 95% van't Riet Conformation Number describing the conformality of a reference dose to the target) while reducing normal tissue integral dose (1.3-fold decrease in the volume receiving 4 Gy (V{sub 4Gy}) and machine output (19% monitor unit (MU) reduction). In trials of planning efficiency, the class solution technique reduced treatment planning time by 30% to 60% and MUs required by {approx}20%: an effect independent of prior planning experience. Conclusions: We have developed a set of class solutions for spinal SBRT that incorporate a pCTV metric for plan evaluation while yielding dosimetrically superior treatment plans with increased planning efficiency. Our technique thus allows for efficient, reproducible, and high-quality spinal SBRT treatment planning.« less

  3. SU-F-T-443: Quantification of Dosimetric Effects of Dental Metallic Implant On VMAT Plans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, C; Jiang, W; Feng, Y

    Purpose: To evaluate the dosimetric impact of metallic implant that correlates with the size of targets and metallic implants and distance in between on volumetric-modulated arc therapy (VMAT) plans for head and neck (H&N) cancer patients with dental metallic implant. Methods: CT images of H&N cancer patients with dental metallic implant were used. Target volumes with different sizes and locations were contoured. Metal artifact regions excluding surrounding critical organs were outlined and assigned with CT numbers close to water (0HU). VMAT plans with half-arc, one-full-arc and two-full-arcs were constructed and same plans were applied to structure sets with and withoutmore » CT number assignment of metal artifact regions and compared. D95% was utilized to investigate PTV dose coverage and SNC Patient− Software was used for the analysis of dose distribution difference slice by slice. Results: For different targets sizes, variation of PTV dose coverage (Delta-D95%) with and without CT number replacement reduced with larger target volume for all half-arc, one-arc and two-arc VMAT plans even though there were no clinically significant differences. Additionally, there were no significant variations of the maximum percent difference (max.%diff) of dose distribution. With regard to the target location, Delta-D95% and max. %diff dropped with increasing distance between target and metallic implant. Furthermore, half-arc plans showed greater impact than one-arc plans, and two-arc plans had smallest influence for PTV dose coverage and dose distribution. Conclusion: The target size has less correlation of doseimetric impact than the target location relative to metallic implants. Plans with more arcs alleviate the dosimetric effect of metal artifact because of less contribution to the target dose from beams going through the regions with metallic artifacts. Incorrect CT number causes inaccurate dose distribution, therefore appropriately overwriting metallic artifact regions with reasonable CT numbers is recommended. More patient data are collected and under further analysis.« less

  4. SU-E-T-10: A Clinical Implementation and the Dosimetric Evidence in High Dose Rate Vaginal Multichannel Applicator Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Syh, J; Syh, J; Patel, B

    2015-06-15

    Purpose: The multichannel cylindrical applicator has a distinctive modification of the traditional single channel cylindrical applicator. The novel multichannel applicator has additional peripheral channels that provide more flexibility both in treatment planning process and outcomes. To protect by reducing doses to adjacent organ at risk (OAR) while maintaining target coverage with inverse plan optimization are the goals for such novel Brachytherapy device. Through a series of comparison and analysis of reults in more than forty patients who received HDR Brachytherapy using multichannel vaginal applicator, this procedure has been implemented in our institution. Methods: Multichannel planning was CT image based. Themore » CTV of 5mm vaginal cuff rind with prescribed length was well reconstructed as well as bladder and rectum. At least D95 of CTV coverage is 95% of prescribed dose. Multichannel inverse plan optimization algorithm not only shapes target dose cloud but set dose avoids to OAR’s exclusively. The doses of D2cc, D5cc and D5; volume of V2Gy in OAR’s were selected to compare with single channel results when sole central channel is only possibility. Results: Study demonstrates plan superiorly in OAR’s doe reduction in multi-channel plan. The D2cc of the rectum and bladder were showing a little lower for multichannel vs. single channel. The V2Gy of the rectum was 93.72% vs. 83.79% (p=0.007) for single channel vs. multichannel respectively. Absolute reduced mean dose of D5 by multichannel was 17 cGy (s.d.=6.4) and 44 cGy (s.d.=15.2) in bladder and rectum respectively. Conclusion: The optimization solution in multichannel was to maintain D95 CTV coverage while reducing the dose to OAR’s. Dosimetric advantage in sparing critical organs by using a multichannel applicator in HDR Brachytherapy treatment of the vaginal cuff is so promising and has been implemented clinically.« less

  5. Immunisation coverage annual report, 2014.

    PubMed

    Hull, Brynley P; Hendry, Alexandra J; Dey, Aditi; Beard, Frank H; Brotherton, Julia M; McIntyre, Peter B

    2017-03-31

    This 8th annual immunisation coverage report shows data for 2014 derived from the Australian Childhood Immunisation Register and the National Human Papillomavirus Vaccination Program Register. This report includes coverage data for 'fully immunised' and by individual vaccines at standard age milestones and timeliness of receipt at earlier ages according to Indigenous status. Overall, 'fully immunised' coverage has been mostly stable at the 12- and 24-month age milestones since late 2003, but at 60 months of age, it has increased by more than 10 percentage points since 2009. As in previous years, coverage for 'fully immunised' at 12 months of age among Indigenous children was 3.7% lower than for non-Indigenous children overall, varying from 6.9 percentage points in Western Australia to 0.3 of a percentage point in the Australian Capital Territory. In 2014, 73.4% of Australian females aged 15 years had 3 documented doses of human papillomavirus vaccine (jurisdictional range 67.7% to 77.4%), and 82.7% had at least 1 dose, compared with 71.4% and 81.5%, respectively, in 2013. The disparity in on-time vaccination between Indigenous and non-Indigenous children in 2014 diminished progressively from 20.2% for vaccines due by 12 months to 11.5% for those due by 24 months and 3.0% at 60 months of age.

  6. Implementation of a human papillomavirus vaccination demonstration project in Malawi: successes and challenges.

    PubMed

    Msyamboza, Kelias Phiri; Mwagomba, Beatrice Matanje; Valle, Moussa; Chiumia, Hastings; Phiri, Twambilire

    2017-06-26

    Cervical cancer is a major public health problem in Malawi. The age-standardized incidence and mortality rates are estimated to be 75.9 and 49.8 per 100,000 population, respectively. The availability of the human papillomavirus (HPV) vaccine presents an opportunity to reduce the morbidity and mortality associated with cervical cancer. In 2013, the country introduced a school-class-based HPV vaccination pilot project in two districts. The aim of this study was to evaluate HPV vaccine coverage, lessons learnt and challenges identified during the first three years of implementation. This was an evaluation of the HPV vaccination project targeting adolescent girls aged 9-13 years conducted in Malawi from 2013 to 2016. We analysed programme data, supportive supervision reports and minutes of National HPV Task Force meetings to determine HPV vaccine coverage, reasons for partial or no vaccination and challenges. Administrative coverage was validated using a community-based coverage survey. A total of 26,766 in-school adolescent girls were fully vaccinated in the two pilot districts during the first three years of the programme. Of these; 2051 (7.7%) were under the age of 9 years, 884 (3.3%) were over the age of 13 years, and 23,831 (89.0%) were aged 9-13 years (the recommended age group). Of the 765 out-of-school adolescent girls aged 9-13 who were identified during the period, only 403 (52.7%) were fully vaccinated. In Zomba district, the coverage rates of fully vaccinated were 84.7%, 87.6% and 83.3% in year 1, year 2 and year 3 of the project, respectively. The overall coverage for the first three years was 82.7%, and the dropout rate was 7.7%. In Rumphi district, the rates of fully vaccinated coverage were 90.2% and 96.2% in year 1 and year 2, respectively, while the overall coverage was 91.3%, and the dropout rate was 4.9%. Administrative (facility-based) coverage for the first year was validated using a community-based cluster coverage survey. The majority of the coverage results were statistically similar, except for in Rumphi district, where community-based 3-dose coverage was higher than the corresponding administrative-coverage (94.2% vs 90.2%, p < 0.05), and overall (in both districts), facility-based 1-dose coverage was higher than the corresponding community-based (94.6% vs 92.6%, p < 0.05). Transferring out of the district, dropping out of school and refusal were some of the reasons for partial or no uptake of the vaccine. In Malawi, the implementation of a school-class-based HPV vaccination strategy was feasible and produced high (>80%) coverage. However, this strategy may be associated with the vaccination of under- and over-aged adolescent girls who are outside of the vaccine manufacturer's stipulated age group (9-13 years). The health facility-based coverage for out-of-school adolescent girls produced low coverage, with only half of the target population being fully vaccinated. These findings highlight the need to assess the immunogenicity associated with the administration of a two-dose schedule to adolescent girls younger or older than 9-13 years and effectiveness of health facility-based strategy before rolling out the programme.

  7. Vaccination coverage and factors influencing routine vaccination status in 12 high risk health zones in the Province of Kinshasa City, Democratic Republic of Congo (DRC), 2015

    PubMed Central

    Mwamba, Guillaume Ngoie; Yoloyolo, Norbert; Masembe, Yolande; Nsambu, Muriel Nzazi; Nzuzi, Cathy; Tshekoya, Patrice; Dah, Barthelemy; Kaya, Guylain

    2017-01-01

    Introduction Vaccination coverage of the first dose of diphtheria-tetanus-pertussis-hepatitis B-Haemophilus influenza type b (pentavalent) vaccine for the City-Province of Kinshasain the years 2012 – 2014 wasbelow the national objective of 92%, with coverage less than 80% reported in 12 of the 35 health zones (HZ). The purpose of this study was to discern potential contributing factors to low vaccination coverage in Kinshasa. Methods We conducted a multi-stage cluster household study of children 6 – 11 months in households residing in their current neighborhood for at least 3 months in the 12 high risk HZ in Kinshasa. Additional information on vaccination status of the children was collected at the health facility. Results Of the 1,513 households with a child 6-11 months old, 81% were eligible and participated. Among the 1224 children surveyed, 96% had received the first dose of pentavalent vaccine; 84% had received the third dose; and 71% had received all recommended vaccines for their age. Longer travel time to get to health facility (p=0.04) and shorter length of residence in the neighborhood (p=0.04) showed significant differences in relation to incomplete vaccination. Forty percent of children received their most recent vaccination in a facility outside of their HZ of residence. Conclusion This survey found vaccination coverage in 12 HZs in Kinshasa was higher than estimates derived from administrative reports. The large percentage of children vaccinated outside of their HZ of residence demonstrates the challenge to use of the Reaching Every District strategy in urban areas. PMID:29296142

  8. Progress Toward Measles Elimination - Western Pacific Region, 2013-2017.

    PubMed

    Hagan, José E; Kriss, Jennifer L; Takashima, Yoshihiro; Mariano, Kayla Mae L; Pastore, Roberta; Grabovac, Varja; Dabbagh, Alya J; Goodson, James L

    2018-05-04

    In 2005, the Regional Committee for the World Health Organization (WHO) Western Pacific Region (WPR)* established a goal for measles elimination † by 2012 (1). To achieve this goal, the 37 WPR countries and areas implemented the recommended strategies in the WPR Plan of Action for Measles Elimination (2) and the Field Guidelines for Measles Elimination (3). The strategies include 1) achieving and maintaining ≥95% coverage with 2 doses of measles-containing vaccine (MCV) through routine immunization services and supplementary immunization activities (SIAs), when required; 2) conducting high-quality case-based measles surveillance, including timely and accurate testing of specimens to confirm or discard suspected cases and detect measles virus for genotyping and molecular analysis; and 3) establishing and maintaining measles outbreak preparedness to ensure rapid response and appropriate case management. This report updates the previous report (4) and describes progress toward measles elimination in WPR during 2013-2017. During 2013-2016, estimated regional coverage with the first MCV dose (MCV1) decreased from 97% to 96%, and coverage with the routine second MCV dose (MCV2) increased from 91% to 93%. Eighteen (50%) countries achieved ≥95% MCV1 coverage in 2016. Seven (39%) of 18 nationwide SIAs during 2013-2017 reported achieving ≥95% administrative coverage. After a record low of 5.9 cases per million population in 2012, measles incidence increased during 2013-2016 to a high of 68.9 in 2014, because of outbreaks in the Philippines and Vietnam, as well as increased incidence in China, and then declined to 5.2 in 2017. To achieve measles elimination in WPR, additional measures are needed to strengthen immunization programs to achieve high population immunity, maintain high-quality surveillance for rapid case detection and confirmation, and ensure outbreak preparedness and prompt response to contain outbreaks.

  9. Using health-facility data to assess subnational coverage of maternal and child health indicators, Kenya.

    PubMed

    Maina, Isabella; Wanjala, Pepela; Soti, David; Kipruto, Hillary; Droti, Benson; Boerma, Ties

    2017-10-01

    To develop a systematic approach to obtain the best possible national and subnational statistics for maternal and child health coverage indicators from routine health-facility data. Our approach aimed to obtain improved numerators and denominators for calculating coverage at the subnational level from health-facility data. This involved assessing data quality and determining adjustment factors for incomplete reporting by facilities, then estimating local target populations based on interventions with near-universal coverage (first antenatal visit and first dose of pentavalent vaccine). We applied the method to Kenya at the county level, where routine electronic reporting by facilities is in place via the district health information software system. Reporting completeness for facility data were well above 80% in all 47 counties and the consistency of data over time was good. Coverage of the first dose of pentavalent vaccine, adjusted for facility reporting completeness, was used to obtain estimates of the county target populations for maternal and child health indicators. The country and national statistics for the four-year period 2012/13 to 2015/16 showed good consistency with results of the 2014 Kenya demographic and health survey. Our results indicated a stagnation of immunization coverage in almost all counties, a rapid increase of facility-based deliveries and caesarean sections and limited progress in antenatal care coverage. While surveys will continue to be necessary to provide population-based data, web-based information systems for health facility reporting provide an opportunity for more frequent, local monitoring of progress, in maternal and child health.

  10. A case study of IMRT planning (Plan B) subsequent to a previously treated IMRT plan (Plan A)

    NASA Astrophysics Data System (ADS)

    Cao, F.; Leong, C.; Schroeder, J.; Lee, B.

    2014-03-01

    Background and purpose: Treatment of the contralateral neck after previous ipsilateral intensity modulated radiation therapy (IMRT) for head and neck cancer is a challenging problem. We have developed a technique that limits the cumulative dose to the spinal cord and brainstem while maximizing coverage of a planning target volume (PTV) in the contralateral neck. Our case involves a patient with right tonsil carcinoma who was given ipsilateral IMRT with 70Gy in 35 fractions (Plan A). A left neck recurrence was detected 14 months later. The patient underwent a neck dissection followed by postoperative left neck radiation to a dose of 66 Gy in 33 fractions (Plan B). Materials and Methods: The spinal cord-brainstem margin (SCBM) was defined as the spinal cord and brainstem with a 1.0 cm margin. Plan A was recalculated on the postoperative CT scan but the fluence outside of SCBM was deleted. A further modification of Plan A resulted in a base plan that was summed with Plan B to evaluate the cumulative dose received by the spinal cord and brainstem. Plan B alone was used to evaluate for coverage of the contralateral neck PTV. Results: The maximum cumulative doses to the spinal cord with 0.5cm margin and brainstem with 0.5cm margin were 51.96 Gy and 45.60 Gy respectively. For Plan B, 100% of the prescribed dose covered 95% of PTVb1. Conclusion: The use of a modified ipsilateral IMRT plan as a base plan is an effective way to limit the cumulative dose to the spinal cord and brainstem while enabling coverage of a PTV in the contralateral neck.

  11. Vitamin A-first dose supplement coverage evaluation amongst children aged 12–23 months residing in slums of Delhi, India

    PubMed Central

    Sachdeva, Sandeep; Datta, Utsuk

    2009-01-01

    Objective: To determine vitamin A-first dose supplement coverage in children aged 12–23 months and to find out its correlates with selected variables. Materials and Methods: The 30-cluster sampling technique based on probability proportional to size advocated by the World Health Organization was used to assess vitamin A-first dose supplement amongst 210 children in the age group of 12–23 months residing in slums of a randomly selected municipal zone of Delhi during October to November 2005. Results: Only 79 (37.6%) children out of 210 had received vitamin A-first dose supplement. Further analysis of 79 children was carried out with regard to selected variables like religion, gender, birth order, place of birth, immunization status and literacy of mother. These analyses showed that 71 (89.9%) were Hindu and eight (10.1%) were non-Hindu (P = 0.04). Nearly 44 (55.7%) males and 35 (44.3%) females had received vitamin A (P = 0.74). The proportion of children born in a health institution who received first dose (57%) of vitamin A supplementation was significantly higher than of those who were born at home (43%) (P < 0.001). Similarly, higher proportion of children with birth order-one (48.1%) in comparison to birth order-three or above (26.6%) received vitamin A (P < 0.001). Thirty children though fully immunized for vaccine-preventable disease up to the age-of-one year had not received vitamin A-first dose supplement, suggesting that an opportunity had been missed. The association between receipt of vitamin A by the child and literacy status of mother was found to be significant (P < 0.001). Conclusion: The study reflects low coverage of Vitamin A supplement. PMID:19574699

  12. IMRT vs. 3D Noncoplanar Treatment Plans for Maxillary Sinus Tumors: A New Tool for Quantitative Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levin, Daphne; Menhel, Janna; Alezra, Dror

    2008-01-01

    We compared 9-field, equispaced intensity modulated radiation therapy (IMRT), 4- to 5-field, directionally optimized IMRT, and 3-dimensional (3D) noncoplanar planning approaches for tumors of the maxillary sinus. Ten patients were planned retrospectively to compare the different treatment techniques. Prescription doses were 60 to 70 Gy. Critical structures contoured included optic nerves and chiasm, lacrimal glands, lenses, and retinas. As an aid for plan assessment, we introduced a new tool: Critical Organ Scoring Index (COSI), which allows quantitative evaluation of the tradeoffs between target coverage and critical organ sparing. This index was compared with other, commonly used conformity indices. For amore » reliable assessment of both tumor coverage and dose to critical organs in the different planning techniques, we introduced a 2D, graphical representation of COSI vs. conformity index (CI). Dose-volume histograms and mean, maximum, and minimum organ doses were also compared. IMRT plans delivered lower doses to ipsilateral structures, but were unable to spare them. 3D plans delivered less dose to contralateral structures, and were more homogeneous, as well. Both IMRT approaches gave similar results. In cases where choice of optimal plan was difficult, the novel 2D COSI-CI representation gave an accurate picture of the tradeoffs between target coverage and organ sparing, even in cases where other conformity indices failed. Due to their unique anatomy, maxillary sinus tumors may benefit more from a noncoplanar approach than from IMRT. The new graphical representation proposed is a quick, visual, reliable tool, which may facilitate the physician's choice of best treatment plan for a given patient.« less

  13. Introduction of Inactivated Poliovirus Vaccine and Impact on Vaccine-Associated Paralytic Poliomyelitis - Beijing, China, 2014-2016.

    PubMed

    Zhao, Dan; Ma, Rui; Zhou, Tao; Yang, Fan; Wu, Jin; Sun, Hao; Liu, Fang; Lu, Li; Li, Xiaomei; Zuo, Shuyan; Yao, Wei; Yin, Jian

    2017-12-15

    When included in a sequential polio vaccination schedule, inactivated polio vaccine (IPV) reduces the risk for vaccine-associated paralytic poliomyelitis (VAPP), a rare adverse event associated with receipt of oral poliovirus vaccine (OPV). During January 2014, the World Health Organization (WHO) recommended introduction of at least 1 IPV dose into routine immunization schedules in OPV-using countries (1). The Polio Eradication and Endgame Strategic Plan 2013-2018 recommended completion of IPV introduction in 2015 and globally synchronized withdrawal of OPV type 2 in 2016 (2). Introduction of 1 dose of IPV into Beijing's Expanded Program on Immunization (EPI) on December 5, 2014 represented China's first province-wide IPV introduction. Coverage with the first dose of polio vaccine was maintained from 96.2% to 96.9%, similar to coverage with the first dose of diphtheria and tetanus toxoids and pertussis vaccine (DTP) (96.5%-97.2%); the polio vaccine dropout rate (the percentage of children who received the first dose of polio vaccine but failed to complete the series) was 1.0% in 2015 and 0.4% in 2016. The use of 3 doses of private-sector IPV per child decreased from 18.1% in 2014, to 17.4% in 2015, and to 14.8% in 2016. No cases of VAPP were identified during 2014-2016. Successful introduction of IPV into the public sector EPI program was attributed to comprehensive planning, preparation, implementation, robust surveillance for adverse events after immunization (AEFI), and monitoring of vaccination coverage. This evaluation provided information that helped contribute to the expansion of IPV use in China and in other OPV-using countries.

  14. Head and Neck Margin Reduction With Adaptive Radiation Therapy: Robustness of Treatment Plans Against Anatomy Changes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kranen, Simon van; Hamming-Vrieze, Olga; Wolf, Annelisa

    Purpose: We set out to investigate loss of target coverage from anatomy changes in head and neck cancer patients as a function of applied safety margins and to verify a cone beam computed tomography (CBCT)–based adaptive strategy with an average patient anatomy to overcome possible target underdosage. Methods and Materials: For 19 oropharyngeal cancer patients, volumetric modulated arc therapy treatment plans (2 arcs; simultaneous integrated boost, 70 and 54.25 Gy; 35 fractions) were automatically optimized with uniform clinical target volume (CTV)–to–planning target volume margins of 5, 3, and 0 mm. We applied b-spline CBCT–to–computed tomography (CT) deformable registration to allow recalculation ofmore » the dose on modified CT scans (planning CT deformed to daily CBCT following online positioning) and dose accumulation in the planning CT scan. Patients with deviations in primary or elective CTV coverage >2 Gy were identified as candidates for adaptive replanning. For these patients, a single adaptive intervention was simulated with an average anatomy from the first 10 fractions. Results: Margin reduction from 5 mm to 3 mm to 0 mm generally led to an organ-at-risk (OAR) mean dose (D{sub mean}) sparing of approximately 1 Gy/mm. CTV shrinkage was mainly seen in the elective volumes (up to 10%), likely related to weight loss. Despite online repositioning, substantial systematic errors were present (>3 mm) in lymph node CTV, the parotid glands, and the larynx. Nevertheless, the average increase in OAR dose was small: maximum of 1.2 Gy (parotid glands, D{sub mean}) for all applied margins. Loss of CTV coverage >2 Gy was found in 1, 3, and 7 of 73 CTVs, respectively. Adaptive intervention in 0-mm plans substantially improved coverage: in 5 of 7 CTVs (in 6 patients) to <2 Gy of initially planned. Conclusions: Volumetric modulated arc therapy head and neck cancer treatment plans with 5-mm margins are robust for anatomy changes and show a modest increase in OAR dose. Margin reduction improves OAR sparing with approximately 1 Gy/mm at the expense of target coverage in a subgroup of patients. Patients at risk of CTV underdosage >2 Gy in 0-mm plans may be identified early in treatment using dose accumulation. A single intervention with an average anatomy derived from CBCT effectively mitigates discrepancies.« less

  15. WE-AB-209-08: Novel Beam-Specific Adaptive Margins for Reducing Organ-At-Risk Doses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsang, H; Kamerling, CP; Ziegenhein, P

    2016-06-15

    Purpose: Current practice of using 3D margins in radiotherapy with high-energy photon beams provides larger-than-required target coverage. According to the photon depth-dose curve, target displacements in beam direction result in minute changes in dose delivered. We exploit this behavior by generating margins on a per-beam basis which simultaneously account for the relative distance of the target and adjacent organs-at-risk (OARs). Methods: For each beam, we consider only geometrical uncertainties of the target location perpendicular to beam direction. By weighting voxels based on its proximity to an OAR, we generate adaptive margins that yield similar overall target coverage probability and reducedmore » OAR dose-burden, at the expense of increased target volume. Three IMRT plans, using 3D margins and 2D per-beam margins with and without adaptation, were generated for five prostate patients with a prescription dose Dpres of 78Gy in 2Gy fractions using identical optimisation constraints. Systematic uncertainties of 1.1, 1.1, 1.5mm in the LR, SI, and AP directions, respectively, and 0.9, 1.1, 1.0mm for the random uncertainties, were assumed. A verification tool was employed to simulate the effects of systematic and random errors using a population size of 50,000. The fraction of the population that satisfies or violates a given DVH constraint was used for comparison. Results: We observe similar target coverage across all plans, with at least 97.5% of the population meeting the D98%>95%Dpres constraint. When looking at the probability of the population receiving D5<70Gy for the rectum, we observed median absolute increases of 23.61% (range, 2.15%–27.85%) and 6.97% (range, 0.65%–17.76%) using per-beam margins with and without adaptation, respectively, relative to using 3D margins. Conclusion: We observed sufficient and similar target coverage using per-beam margins. By adapting each per-beam margin away from an OAR, we can further reduce OAR dose without significantly lowering target coverage probability by irradiating more less-important tissues. This work is supported by Cancer Research UK under Programme C33589/A19908. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR.« less

  16. Comparison of Dose Decrement from Intrafraction Motion for Prone and Supine Prostate Radiotherapy

    PubMed Central

    Olsen, Jeffrey; Parikh, Parag J; Watts, Michael; Noel, Camille E; Baker, Kenneth W; Santanam, Lakshmi; Michalski, Jeff M

    2012-01-01

    Background and Purpose Dose effects of intrafraction motion during prone prostate radiotherapy are unknown. We compared prone and supine treatment using real-time tracking data to model dose coverage. Material and Methods Electromagnetic tracking data was analyzed for 10 patients treated prone, and 15 treated supine, with IMRT for localized prostate cancer. Plans were generated using 0, 3, and 5 mm PTV expansions. Manual beam-hold interventions were applied to reposition the patient when translations exceeded a predetermined threshold. A custom software application (SWIFTER) used intrafraction tracking data acquired during beam-on to model delivered prostate dose, by applying rigid body transformations to the prostate structure contoured at simulation within the planned dose cloud. The delivered minimum prostate dose as a percentage of planned dose (Dmin%), and prostate volume covered by the prescription dose as a percentage of the planned volume (VRx%) were compared for prone and supine treatment. Results Dmin% was reduced for prone treatment for 0 (p=0.02) and 3 mm (p=0.03) PTV margins. VRx% was reduced for prone treatment only for 0 mm margins (p=0.002). No significant differences were found using 5 mm margins. Conclusions Intrafraction motion has a greater impact on target coverage for prone compared to supine prostate radiotherapy. PTV margins of 3 mm or less correlate with a significant decrease in delivered dose for prone treatment. PMID:22809590

  17. Comparison of dose decrement from intrafraction motion for prone and supine prostate radiotherapy.

    PubMed

    Olsen, Jeffrey R; Parikh, Parag J; Watts, Michael; Noel, Camille E; Baker, Kenneth W; Santanam, Lakshmi; Michalski, Jeff M

    2012-08-01

    Dose effects of intrafraction motion during prone prostate radiotherapy are unknown. We compared prone and supine treatment using real-time tracking data to model dose coverage. Electromagnetic tracking data were analyzed for 10 patients treated prone, and 15 treated supine, with IMRT for localized prostate cancer. Plans were generated using 0 mm, 3 mm, and 5mm PTV expansions. Manual beam-hold interventions were applied to reposition the patient when translations exceeded a predetermined threshold. A custom software application (SWIFTER) used intrafraction tracking data acquired during beam-on model delivered prostate dose, by applying rigid body transformations to the prostate structure contoured at simulation within the planned dose cloud. The delivered minimum prostate dose as a percentage of planned dose (Dmin%), and prostate volume covered by the prescription dose as a percentage of the planned volume (VRx%) were compared for prone and supine treatment. Dmin% was reduced for prone treatment for 0 (p=0.02) and 3 mm (p=0.03) PTV margins. VRx% was reduced for prone treatment only for 0mm margins (p=0.002). No significant differences were found using 5 mm margins. Intrafraction motion has a greater impact on target coverage for prone compared to supine prostate radiotherapy. PTV margins of 3 mm or less correlate with a significant decrease in delivered dose for prone treatment. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  18. Evaluation of delivered dose for a clinical daily adaptive plan selection strategy for bladder cancer radiotherapy.

    PubMed

    Lutkenhaus, Lotte J; Visser, Jorrit; de Jong, Rianne; Hulshof, Maarten C C M; Bel, Arjan

    2015-07-01

    To account for variable bladder size during bladder cancer radiotherapy, a daily plan selection strategy was implemented. The aim of this study was to calculate the actually delivered dose using an adaptive strategy, compared to a non-adaptive approach. Ten patients were treated to the bladder and lymph nodes with an adaptive full bladder strategy. Interpolated delineations of bladder and tumor on a full and empty bladder CT scan resulted in five PTVs for which VMAT plans were created. Daily cone beam CT (CBCT) scans were used for plan selection. Bowel, rectum and target volumes were delineated on these CBCTs, and delivered dose for these was calculated using both the adaptive plan, and a non-adaptive plan. Target coverage for lymph nodes improved using an adaptive strategy. The full bladder strategy spared the healthy part of the bladder from a high dose. Average bowel cavity V30Gy and V40Gy significantly reduced with 60 and 69ml, respectively (p<0.01). Other parameters for bowel and rectum remained unchanged. Daily plan selection compared to a non-adaptive strategy yielded similar bladder coverage and improved coverage for lymph nodes, with a significant reduction in bowel cavity V30Gy and V40Gy only, while other sparing was limited. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. Impact of Spot Size and Spacing on the Quality of Robustly Optimized Intensity Modulated Proton Therapy Plans for Lung Cancer.

    PubMed

    Liu, Chenbin; Schild, Steven E; Chang, Joe Y; Liao, Zhongxing; Korte, Shawn; Shen, Jiajian; Ding, Xiaoning; Hu, Yanle; Kang, Yixiu; Keole, Sameer R; Sio, Terence T; Wong, William W; Sahoo, Narayan; Bues, Martin; Liu, Wei

    2018-06-01

    To investigate how spot size and spacing affect plan quality, robustness, and interplay effects of robustly optimized intensity modulated proton therapy (IMPT) for lung cancer. Two robustly optimized IMPT plans were created for 10 lung cancer patients: first by a large-spot machine with in-air energy-dependent large spot size at isocenter (σ: 6-15 mm) and spacing (1.3 σ), and second by a small-spot machine with in-air energy-dependent small spot size (σ: 2-6 mm) and spacing (5 mm). Both plans were generated by optimizing radiation dose to internal target volume on averaged 4-dimensional computed tomography scans using an in-house-developed IMPT planning system. The dose-volume histograms band method was used to evaluate plan robustness. Dose evaluation software was developed to model time-dependent spot delivery to incorporate interplay effects with randomized starting phases for each field per fraction. Patient anatomy voxels were mapped phase-to-phase via deformable image registration, and doses were scored using in-house-developed software. Dose-volume histogram indices, including internal target volume dose coverage, homogeneity, and organs at risk (OARs) sparing, were compared using the Wilcoxon signed-rank test. Compared with the large-spot machine, the small-spot machine resulted in significantly lower heart and esophagus mean doses, with comparable target dose coverage, homogeneity, and protection of other OARs. Plan robustness was comparable for targets and most OARs. With interplay effects considered, significantly lower heart and esophagus mean doses with comparable target dose coverage and homogeneity were observed using smaller spots. Robust optimization with a small spot-machine significantly improves heart and esophagus sparing, with comparable plan robustness and interplay effects compared with robust optimization with a large-spot machine. A small-spot machine uses a larger number of spots to cover the same tumors compared with a large-spot machine, which gives the planning system more freedom to compensate for the higher sensitivity to uncertainties and interplay effects for lung cancer treatments. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume.

    PubMed

    Admiraal, Marjan A; Schuring, Danny; Hurkmans, Coen W

    2008-01-01

    The purpose of this study was to determine the 4D accumulated dose delivered to the CTV in stereotactic radiotherapy of lung tumours, for treatments planned on an average CT using an ITV derived from the Maximum Intensity Projection (MIP) CT. For 10 stage I lung cancer patients, treatment plans were generated based on 4D-CT images. From the 4D-CT scan, 10 time-sorted breathing phases were derived, along with the average CT and the MIP. The ITV with a margin of 0mm was used as a PTV to study a worst case scenario in which the differences between 3D planning and 4D dose accumulation will be largest. Dose calculations were performed on the average CT. Dose prescription was 60Gy to 95% of the PTV, and at least 54Gy should be received by 99% of the PTV. Plans were generated using the inverse planning module of the Pinnacle(3) treatment planning system. The plans consisted of nine coplanar beams with two segments each. After optimisation, the treatment plan was transferred to all breathing phases and the delivered dose per phase was calculated using an elastic body spline model available in our research version of Pinnacle (8.1r). Then, the cumulative dose to the CTV over all breathing phases was calculated and compared to the dose distribution of the original treatment plan. Although location, tumour size and breathing-induced tumour movement varied widely between patients, the PTV planning criteria could always be achieved without compromising organs at risk criteria. After 4D dose calculations, only very small differences between the initial planned PTV coverage and resulting CTV coverage were observed. For all patients, the dose delivered to 99% of the CTV exceeded 54Gy. For nine out of 10 patients also the criterion was met that the volume of the CTV receiving at least the prescribed dose was more than 95%. When the target dose is prescribed to the ITV (PTV=ITV) and dose calculations are performed on the average CT, the cumulative CTV dose compares well to the planned dose to the ITV. Thus, the concept of treatment plan optimisation and evaluation based on the average CT and the ITV is a valid approach in stereotactic lung treatment. Even with a zero ITV to PTV margin, no significantly different dose coverage of the CTV arises from the breathing motion induced dose variation over time.

  1. The Norwegian immunisation register--SYSVAK.

    PubMed

    Trogstad, L; Ung, G; Hagerup-Jenssen, M; Cappelen, I; Haugen, I L; Feiring, B

    2012-04-19

    The Norwegian immunisation register, SYSVAK, is a national electronic immunisation register. It became nationwide in 1995. The major aim was to register all vaccinations in the Childhood Immunisation Programme to ensure that all children are offered adequate vaccination according to schedule in the programme, and to secure high vaccination coverage. Notification to SYSVAK is mandatory, based on personal identification numbers. This allows follow up of individual vaccination schedules and linkage of SYSVAK data to other national health registers for information on outcome diagnoses, such as the surveillance system for communicable diseases. Information from SYSVAK is used to determine vaccine coverage in a timely manner. Coverage can be broken down to regional/local levels and used for active surveillance of vaccination coverage and decisions about interventions. During the 2009 influenza A(H1N1)pdm09 pandemic, an adaptation of SYSVAK enabled daily surveillance of vaccination coverage on national and regional levels. Currently, data from SYSVAK are used, among others, in studies on adverse events related to pandemic vaccination. Future challenges include maximising usage of collected data in surveillance and research, and continued improvement of data quality. Immunisation registers are rich sources for high quality surveillance of vaccination coverage, effectiveness, vaccine failure and adverse events, and gold mines for research.

  2. Implementing the communication for development strategy to improve knowledge and coverage of measles vaccination in western Chinese immunization programs: a before-and-after evaluation.

    PubMed

    Lu, Ming; Chu, Yao-Zhu; Yu, Wen-Zhou; Scherpbier, Robert; Zhou, Yu-Qing; Zhu, Xu; Su, Qi-Ru; Duan, Meng-Juan; Zhang, Xuan; Cui, Fu-Qiang; Wang, Hua-Qing; Zhou, Yi-Biao; Jiang, Qing-Wu

    2017-04-24

    Communication for Development (C4D) is a strategy promoted by the United Nations Children's Fund to foster positive and measurable changes at the individual, family, community, social, and policy levels of society. In western China, C4D activities have previously been conducted as part of province-level immunization programs. In this study, we evaluated the association of C4D with changes in parental knowledge of immunization services, measles disease, and measles vaccine, and changes in their children's measles vaccine coverage. From April 2013 to April 2014, C4D activities were implemented as part of provincial immunization programs in the Inner Mongolia, Guangxi, Chongqing, Guizhou, Tibet, Shaanxi, Gansu, Ningxia, and Qinghai provinces. We used a before-and-after study design and employed face-to-face interviews to assess changes in parental knowledge and vaccination coverage. We surveyed 2 107 households at baseline and 2 070 households after 1 year of C4D activities. Following C4D, 95% of caregivers were aware of the vaccination record check requirement for entry into kindergarten and primary school; 80% of caregivers were aware that migrant children were eligible for free vaccination; more than 70% of caregivers knew that measles is a respiratory infectious disease; and 90% of caregivers knew the symptoms of measles. Caregivers' willingness to take their children to the clinic for vaccination increased from 51.3% at baseline to 67.4% in the post-C4D survey. Coverage of one-dose measles-containing vaccine (MCV) increased from 83.8% at baseline to 90.1% after C4D. One-dose MCV coverage was greater than 95% in the Guangxi, Shaanxi, and Gansu provinces. Two-dose MCV coverage increased from 68.5 to 77.6%. House-to-house communication was the most popular C4D activity among caregivers (91.6% favoring), followed by posters and educational talks (64.8 and 49.9% favoring). C4D is associated with increased caregiver knowledge about measles, increased willingness to seek immunization services for their children, and increased measles vaccination coverage. Tailored communication strategies based on insights gained from these analyses may be able to increase vaccination coverage in hard-to-reach areas. C4D should be considered for larger scale implementation in China.

  3. Dose coverage calculation using a statistical shape model—applied to cervical cancer radiotherapy

    NASA Astrophysics Data System (ADS)

    Tilly, David; van de Schoot, Agustinus J. A. J.; Grusell, Erik; Bel, Arjan; Ahnesjö, Anders

    2017-05-01

    A comprehensive methodology for treatment simulation and evaluation of dose coverage probabilities is presented where a population based statistical shape model (SSM) provide samples of fraction specific patient geometry deformations. The learning data consists of vector fields from deformable image registration of repeated imaging giving intra-patient deformations which are mapped to an average patient serving as a common frame of reference. The SSM is created by extracting the most dominating eigenmodes through principal component analysis of the deformations from all patients. The sampling of a deformation is thus reduced to sampling weights for enough of the most dominating eigenmodes that describe the deformations. For the cervical cancer patient datasets in this work, we found seven eigenmodes to be sufficient to capture 90% of the variance in the deformations of the, and only three eigenmodes for stability in the simulated dose coverage probabilities. The normality assumption of the eigenmode weights was tested and found relevant for the 20 most dominating eigenmodes except for the first. Individualization of the SSM is demonstrated to be improved using two deformation samples from a new patient. The probabilistic evaluation provided additional information about the trade-offs compared to the conventional single dataset treatment planning.

  4. Beyond new vaccine introduction: the uptake of pneumococcal conjugate vaccine in the African Region.

    PubMed

    Olayinka, Folake; Ewald, Leah; Steinglass, Robert

    2017-01-01

    The number of vaccines available to low-income countries has increased dramatically over the last decade. Overall infant immunization coverage in the WHO African region has stagnated in the past few years while countries' ability to maintain high immunization coverage rates following introduction of new vaccines has been uneven. This case study examines post-introduction coverage among African countries that introduced PCV between 2008 and 2013 and the factors affecting Pneumococcal Conjugate Vaccine (PCV) introduction. Nearly one-third of countries did not achieve 80% infant PCV3 coverage by two years post-introduction and 58% of countries experienced a decline in coverage between post introduction years two and four. Major factors affecting coverage rates included introduction without adequate preparation, insufficient supply chain capacity and management, poor communication between organizations and with the public, and data collection systems that were insufficient to meet information needs. Deliberately addressing these issues as well as longstanding weaknesses during new vaccine introduction can strengthen the immunization and broader health system. Further study is required to identify and address factors that affect maintenance of high coverage following introduction of new vaccines in the African region. Immunization with PCV is one of the most important interventions protecting against pneumonia, the second leading cause of death for children under five globally.

  5. Trends in, and projections of, indicators of universal health coverage in Bangladesh, 1995-2030: a Bayesian analysis of population-based household data.

    PubMed

    Rahman, Md Shafiur; Rahman, Md Mizanur; Gilmour, Stuart; Swe, Khin Thet; Krull Abe, Sarah; Shibuya, Kenji

    2018-01-01

    Many countries are implementing health system reforms to achieve universal health coverage (UHC) by 2030. To understand the progress towards UHC in Bangladesh, we estimated trends in indicators of the health service and of financial risk protection. We also estimated the probability of Bangladesh's achieving of UHC targets of 80% essential health-service coverage and 100% financial risk protection by 2030. We estimated the coverage of UHC indicators-13 prevention indicators and four treatment indicators-from 19 nationally representative population-based household surveys done in Bangladesh from Jan 1, 1991, to Dec 31, 2014. We used a Bayesian regression model to estimate the trend and to predict the coverage of UHC indicators along with the probabilities of achieving UHC targets of 80% coverage of health services and 100% coverage of financial risk protection from catastrophic and impoverishing health payments by 2030. We used the concentration index and relative index of inequality to assess wealth-based inequality in UHC indicators. If the current trends remain unchanged, we estimated that coverage of childhood vaccinations, improved water, oral rehydration treatment, satisfaction with family planning, and non-use of tobacco will achieve the 80% target by 2030. However, coverage of four antenatal care visits, facility-based delivery, skilled birth attendance, postnatal checkups, care seeking for pneumonia, exclusive breastfeeding, non-overweight, and adequate sanitation were not projected to achieve the target. Quintile-specific projections showed wide wealth-based inequality in access to antenatal care, postnatal care, delivery care, adequate sanitation, and care seeking for pneumonia, and this inequality was projected to continue for all indicators. The incidence of catastrophic health expenditure and impoverishment were projected to increase from 17% and 4%, respectively, in 2015, to 20% and 9%, respectively, by 2030. Inequality analysis suggested that wealthiest households would disproportionately face more financial catastrophe than the most disadvantaged households. Despite progress, Bangladesh will not achieve the 2030 UHC targets unless the country scales up interventions related to maternal and child health services, and reforms health financing systems to avoid high dependency on out-of-pocket payments. The introduction of a national health insurance system, increased public funding for health care, and expansion of community-based clinics in rural areas could help to move the country towards UHC. Japan Ministry of Health, Labour, and Welfare. Copyright © 2018 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY-NC-ND 4.0 license. Published by Elsevier Ltd.. All rights reserved.

  6. Continued midazolam versus diphenhydramine in difficult-to-sedate patients: a randomized double-blind trial.

    PubMed

    Sachar, Hamita; Pichetshote, Nipaporn; Nandigam, Kavitha; Vaidya, Keta; Laine, Loren

    2018-05-01

    Current guidelines recommend diphenhydramine in patients undergoing endoscopy who are not adequately sedated with a benzodiazepine and opioid combination. Because this practice has not been adequately assessed, we performed a randomized, double-blind trial comparing diphenhydramine with continued midazolam in such patients. Patients undergoing elective colonoscopy with moderate sedation were eligible. Sedation was measured with the Modified Observer's Assessment of Alertness/Sedation (MOAA/S) score with adequate sedation defined as 3 on a 0- to 5-point scale. Patients not adequately sedated with midazolam 5 mg and fentanyl 100 μg were randomly assigned to diphenhydramine 25 mg versus continued midazolam 1.5 mg. Adequacy of sedation was assessed 3 minutes after each study medication dose. If MOAA/S was 4 to 5, study medication was repeated, to a maximum of 3 doses. The primary endpoint was adequate sedation. The planned enrollment of 200 patients (100 in each study group) was attained. Adequate sedation was achieved less often with diphenhydramine than midazolam (27% vs 65%, difference = -38%; 95% CI, -50% to -24%; P < .0001). After study medications were completed, more patients required additional medication for sedation or analgesia with diphenhydramine versus midazolam (84% vs 68%, P = .008), whereas the time to discharge from the recovery unit was similar (134 vs 129 minutes). Treatment effect was consistent across subgroups including age ≤55, substance abuse, benzodiazepine use, opioid use, and psychiatric medication use. Endoscopists performing moderate sedation should continue midazolam rather than switching to diphenhydramine in patients who do not achieve adequate sedation with usual doses of midazolam and an opioid. (Clinical trial registration number: NCT01769586.). Published by Elsevier Inc.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mwidu, U; Devic, S; Shehadeh, M

    Purpose: A retrospective comparison of dose distributions achievable by High dose rate brachytherapy (HDRBT), Helical TomoTherapy (TOMO), CyberKnife (CK) and RapidArc (RA) in locally advanced inoperable cervical cancer patients is presented. Methods: Five patients with advanced stage cervical carcinoma were selected for this study after a full course of external beam radiotherapy (EBRT), chemotherapy and HDR Brachytherapy. To highlight any significant similarities/differences in dose distributions, high-risk clinical target volume (HRCTV) coverage, organs at risk (OAR) sparing, and machine specific delivery limitations, we used D90 (dose received by 90% of the volume) as the parameter for HRCTV coverage as recommended bymore » the GEC-ESTRO Working Group. We also compared both integral and differential dose volume histograms (DVH) between different dose distributions treatment modalities for HRCTV and OAR. Results: TOMO and RA provided the most conformal dose distributions to HRCTV. Median doses (in Gy) to organs at risk were; for rectal wall: 1.7±0.6, 2.5±0.6,1.2±0.3, and 1.5±0.6, and for bladder wall: 1.6±0.1, 2.4±0.4, 0.8±0.6, and 1.5±0.5, for HDRBT, TOMO, CK, and RA, respectively. Conclusion: Contemporary EBRT modalities might be able to replace brachytherapy treatments for cervix cancer. While brachytherapy dose distributions feature high dose gradients, EBRT modalities provide highly conformal dose distributions to the target. However, it is still not clear whether a highly conformal dose or high gradient dose is more clinically relevant for the HRCTV in cervix cancer patients.« less

  8. Organ dose conversion coefficients for tube current modulated CT protocols for an adult population

    NASA Astrophysics Data System (ADS)

    Fu, Wanyi; Tian, Xiaoyu; Sahbaee, Pooyan; Zhang, Yakun; Segars, William Paul; Samei, Ehsan

    2016-03-01

    In computed tomography (CT), patient-specific organ dose can be estimated using pre-calculated organ dose conversion coefficients (organ dose normalized by CTDIvol, h factor) database, taking into account patient size and scan coverage. The conversion coefficients have been previously estimated for routine body protocol classes, grouped by scan coverage, across an adult population for fixed tube current modulated CT. The coefficients, however, do not include the widely utilized tube current (mA) modulation scheme, which significantly impacts organ dose. This study aims to extend the h factors and the corresponding dose length product (DLP) to create effective dose conversion coefficients (k factor) database incorporating various tube current modulation strengths. Fifty-eight extended cardiac-torso (XCAT) phantoms were included in this study representing population anatomy variation in clinical practice. Four mA profiles, representing weak to strong mA dependency on body attenuation, were generated for each phantom and protocol class. A validated Monte Carlo program was used to simulate the organ dose. The organ dose and effective dose was further normalized by CTDIvol and DLP to derive the h factors and k factors, respectively. The h factors and k factors were summarized in an exponential regression model as a function of body size. Such a population-based mathematical model can provide a comprehensive organ dose estimation given body size and CTDIvol. The model was integrated into an iPhone app XCATdose version 2, enhancing the 1st version based upon fixed tube current modulation. With the organ dose calculator, physicists, physicians, and patients can conveniently estimate organ dose.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meyer, Jeff, E-mail: jmeye3@utsouthwestern.ed; Bluett, Jaques; Amos, Richard

    Purpose: Conventional proton therapy with passively scattered beams is used to treat a number of tumor sites, including prostate cancer. Spot scanning proton therapy is a treatment delivery means that improves conformal coverage of the clinical target volume (CTV). Placement of individual spots within a target is dependent on traversed tissue density. Errors in patient alignment perturb dose distributions. Moreover, there is a need for a rational planning approach that can mitigate the dosimetric effect of random alignment errors. We propose a treatment planning approach and then analyze the consequences of various simulated alignment errors on prostate treatments. Methods andmore » Materials: Ten control patients with localized prostate cancer underwent treatment planning for spot scanning proton therapy. After delineation of the clinical target volume, a scanning target volume (STV) was created to guide dose coverage. Errors in patient alignment in two axes (rotational and yaw) as well as translational errors in the anteroposterior direction were then simulated, and dose to the CTV and normal tissues were reanalyzed. Results: Coverage of the CTV remained high even in the setting of extreme rotational and yaw misalignments. Changes in the rectum and bladder V45 and V70 were similarly minimal, except in the case of translational errors, where, as a result of opposed lateral beam arrangements, much larger dosimetric perturbations were observed. Conclusions: The concept of the STV as applied to spot scanning radiation therapy and as presented in this report leads to robust coverage of the CTV even in the setting of extreme patient misalignments.« less

  10. A Social Potential Fields Approach for Self-Deployment and Self-Healing in Hierarchical Mobile Wireless Sensor Networks

    PubMed Central

    González-Parada, Eva; Cano-García, Jose; Aguilera, Francisco; Sandoval, Francisco; Urdiales, Cristina

    2017-01-01

    Autonomous mobile nodes in mobile wireless sensor networks (MWSN) allow self-deployment and self-healing. In both cases, the goals are: (i) to achieve adequate coverage; and (ii) to extend network life. In dynamic environments, nodes may use reactive algorithms so that each node locally decides when and where to move. This paper presents a behavior-based deployment and self-healing algorithm based on the social potential fields algorithm. In the proposed algorithm, nodes are attached to low cost robots to autonomously navigate in the coverage area. The proposed algorithm has been tested in environments with and without obstacles. Our study also analyzes the differences between non-hierarchical and hierarchical routing configurations in terms of network life and coverage. PMID:28075364

  11. A Social Potential Fields Approach for Self-Deployment and Self-Healing in Hierarchical Mobile Wireless Sensor Networks.

    PubMed

    González-Parada, Eva; Cano-García, Jose; Aguilera, Francisco; Sandoval, Francisco; Urdiales, Cristina

    2017-01-09

    Autonomous mobile nodes in mobile wireless sensor networks (MWSN) allow self-deployment and self-healing. In both cases, the goals are: (i) to achieve adequate coverage; and (ii) to extend network life. In dynamic environments, nodes may use reactive algorithms so that each node locally decides when and where to move. This paper presents a behavior-based deployment and self-healing algorithm based on the social potential fields algorithm. In the proposed algorithm, nodes are attached to low cost robots to autonomously navigate in the coverage area. The proposed algorithm has been tested in environments with and without obstacles. Our study also analyzes the differences between non-hierarchical and hierarchical routing configurations in terms of network life and coverage.

  12. 24 CFR 401.460 - Modification or refinancing of first mortgage.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... modification under the Restructuring Plan. The debt service coverage used by the PAE must be adequate for... RESTRUCTURING, DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT MULTIFAMILY HOUSING MORTGAGE AND HOUSING ASSISTANCE RESTRUCTURING PROGRAM (MARK-TO-MARKET) Restructuring Plan § 401.460 Modification or refinancing of first...

  13. Improving birth dose coverage of hepatitis B vaccine.

    PubMed Central

    Hipgrave, David B.; Maynard, James E.; Biggs, Beverley-Ann

    2006-01-01

    Administration of a birth dose of hepatitis B vaccine (HepB vaccine) to neonates is recommended to prevent mother-to-infant transmission and chronic infection with the hepatitis B virus (HBV). Although manufacturers recommend HepB vaccine distribution and storage at 2-8 degrees C, recognition of the heat stability of hepatitis B surface antigen stimulated research into its use after storage at, or exposure to, ambient or high temperatures. Storage of HepB vaccine at ambient temperatures would enable birth dosing for neonates delivered at home in remote areas or at health posts lacking refrigeration. This article reviews the current evidence on the thermostability of HepB vaccine when stored outside the cold chain (OCC). The reports reviewed show that the vaccines studied were safe and effective whether stored cold or OCC. Field and laboratory data also verifies the retained potency of the vaccine after exposure to heat. The attachment of a highly stable variety of a vaccine vial monitor (measuring cumulative exposure to heat) on many HepB vaccines strongly supports policies allowing their storage OCC, when this will benefit birth dose coverage. We recommend that this strategy be introduced to improve birth dose coverage, especially in rural and remote areas. Concurrent monitoring and evaluation should be undertaken to affirm the safe implementation of this strategy, and assess its cost, feasibility and effect on reducing HBV infection rates. Meanwhile, release of manufacturer data verifying the potency of currently available HepB vaccines after exposure to heat will increase confidence in the use of vaccine vial monitors as a managerial tool during storage of HepB vaccine OCC. PMID:16501717

  14. Does closure of children's medical home impact their immunization coverage?

    PubMed

    Kolasa, M S; Stevenson, J; Ossa, A; Lutz, J

    2014-12-01

    Little is known about the impact closing a health care facility has on immunization coverage of children utilizing that facility as a medical home. The authors assessed the impact of closing a Medicaid managed care facility in Philadelphia on immunization coverage of children, primarily low income children from racial/ethnic minority groups, utilizing that facility for routine immunizations. Observational longitudinal cohort case study. Eligible children were born 03/01/05-06/30/07, present in Philadelphia's immunization information system (IIS), and were active clients of the facility before it closed in September 2007. IIS-recorded immunization coverage at ages 5, 7, 13, 16 and 19 months through January 2009 was compared between clinic children age-eligible to receive specific vaccines before clinic closing (preclosure cohorts) and children not age-eligible to receive those vaccines prior to closing (postclosure cohorts). Of 630 eligible children, 99 (16%) had no additional IIS-recorded immunizations. Third dose DTaP vaccine coverage at age seven months among preclosure cohorts was 54.4% vs. 40.3% among postclosure cohorts [risk ratio 1.31 (1.15,1.49)]. Fourth dose DTaP coverage at 19 months was 65.9% vs. 57.7% [risk ratio 1.24 (1.08,1.42)]. MMR coverage at 16 months was 79.5% vs. 69.9% [risk ratio 1.47 (1.22, 1.76)]. Coverage for the 431331 vaccination series at 19 months was 63.8% vs. 53.8% [risk ratio 1.28 (1.12,1.88)]. Immunization coverage declined at key age milestones for active clients of a Medicaid managed care that closed as compared with preclosure cohorts of clients from the same facility. When a primary health care facility closes, efforts should be made to ensure that children who had received vaccinations at that facility quickly establish a new medical home. Published by Elsevier Ltd.

  15. Impact of the addition of new vaccines in the early childhood schedule on vaccine coverage by 24 months of age from 2006 to 2016 in Quebec, Canada.

    PubMed

    Kiely, Marilou; Boulianne, Nicole; Talbot, Denis; Ouakki, Manale; Guay, Maryse; Landry, Monique; Zafack, Joseline; Sauvageau, Chantal; De Serres, Gaston

    2018-07-05

    Between 2004 and 2016, in the province of Quebec (Canada), 4 new antigens were added in the early childhood vaccine schedule from birth to 18 months, increasing the number of injections or doses needed from 7 to 12. These additions may have decreased the proportion of children who had received all recommended vaccines. To assess the impact of the introduction of new vaccines to the childhood schedule on the 24-month vaccine coverage from 2006 to 2016 and identify factors associated with incomplete vaccination status by 24 months of age. We used the data from six cross-sectional vaccine coverage surveys conducted every two years which included a total of 3515 children aged 2 years old and randomly selected from the Quebec public health insurance database. Factors associated with an incomplete vaccine status by 24 months were identified with multivariable logistic regression. Despite the addition of 4 new vaccine antigens since 2004, the vaccine coverage remained high from 2006 (82.4%) through 2016 (88.3%) for vaccines present in the schedule since 2006. In 2016, vaccine coverage was 78.2% for all vaccines included in the schedule. The vaccine coverage of new vaccines increases rapidly within 2 years of their introduction. For both new and older vaccines, incomplete vaccine status by 24 months of age is associated with a delay of 30 days or more in receiving the vaccines scheduled at 2 and 12 months of age. Increasing to 12 the number of doses in the recommended schedule has slightly reduced the vaccine coverage by 24 months of age and the vaccine coverage of vaccines already in the schedule remained stable over the years. Future additions to the vaccine schedule may not be similarly accepted by the population and this will require continuing the monitoring of vaccine coverage. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Crude childhood vaccination coverage in West Africa: Trends and predictors of completeness.

    PubMed

    Kazungu, Jacob S; Adetifa, Ifedayo M O

    2017-02-15

    Background : Africa has the lowest childhood vaccination coverage worldwide. If the full benefits of childhood vaccination programmes are to be enjoyed in sub-Saharan Africa, all countries need to improve on vaccine delivery to achieve and sustain high coverage. In this paper, we review trends in vaccination coverage, dropouts between vaccine doses and explored the country-specific predictors of complete vaccination in West Africa.  Methods : We utilized datasets from the Demographic and Health Surveys Program, available for Benin, Burkina Faso, The Gambia, Ghana, Guinea, Cote d'Ivoire, Liberia, Mali, Niger, Nigeria, Senegal, Sierra Leone and Togo, to obtain coverage for Bacillus Calmette-Guerin, polio, measles, and diphtheria, pertussis and tetanus (DPT) vaccines in children aged 12 - 23 months. We also calculated the DPT1-to-DPT3 and DPT1-to-measles dropouts, and proportions of the fully immunised child (FIC). Factors predictive of FIC were explored using Chi-squared tests and multivariable logistic regression.  Results : Overall, there was a trend of increasing vaccination coverage. The proportion of FIC varied significantly by country (range 24.1-81.4%, mean 49%). DPT1-to-DPT3 dropout was high (range 5.1% -33.9%, mean 16.3%). Similarly, DPT1-measles dropout exceeded 10% in all but four countries. Although no single risk factor was consistently associated with FIC across these countries, maternal education, delivery in a health facility, possessing a vaccine card and a recent post delivery visit to a health facility were the key predictors of complete vaccination.  Conclusions : The low numbers of fully immunised children and high dropout between vaccine doses highlights weaknesses and the need to strengthen the healthcare and routine immunization delivery systems in this region. Country-specific correlates of complete vaccination should be explored further to identify interventions required to increase vaccination coverage. Despite the promise of an increasing trend in vaccination coverage in West African countries, more effort is required to attain and maintain global vaccination coverage targets.

  17. Estimating Benzathine Penicillin Need for the Treatment of Pregnant Women Diagnosed with Syphilis during Antenatal Care in High-Morbidity Countries

    PubMed Central

    Taylor, Melanie M.; Nurse-Findlay, Stephen; Zhang, Xiulei; Hedman, Lisa; Kamb, Mary L.; Broutet, Nathalie; Kiarie, James

    2016-01-01

    Background Congenital syphilis continues to be a preventable cause of global stillbirth and neonatal morbidity and mortality. Shortages of injectable penicillin, the only recommended treatment for pregnant women and infants with syphilis, have been reported by high-morbidity countries. We sought to estimate current and projected annual needs for benzathine penicillin in antenatal care settings for 30 high morbidity countries that account for approximately 33% of the global burden of congenital syphilis. Methods Proportions of antenatal care attendance, syphilis screening coverage in pregnancy, syphilis prevalence among pregnant women, and adverse pregnancy outcomes due to untreated maternal syphilis reported to WHO were applied to 2012 birth estimates for 30 high syphilis burden countries to estimate current and projected benzathine penicillin need for prevention of congenital syphilis. Results Using current antenatal care syphilis screening coverage and seroprevalence, we estimated the total number of women requiring treatment with at least one injection of 2.4 MU of benzathine penicillin in these 30 countries to be 351,016. Syphilis screening coverage at or above 95% for all 30 countries would increase the number of women requiring treatment with benzathine penicillin to 712,030. Based on WHO management guidelines, 351,016 doses of weight-based benzathine penicillin would also be needed for the live-born infants of mothers who test positive and are treated for syphilis in pregnancy. Assuming availability of penicillin and provision of treatment for all mothers diagnosed with syphilis, an estimated 95,938 adverse birth outcomes overall would be prevented including 37,822 stillbirths, 15,814 neonatal deaths, and 34,088 other congenital syphilis cases. Conclusion Penicillin need for maternal and infant syphilis treatment is high among this group of syphilis burdened countries. Initiatives to ensure a stable and adequate supply of benzathine penicillin for treatment of maternal syphilis are important for congenital syphilis prevention, and will be increasingly critical in the future as more countries move toward elimination targets. PMID:27434236

  18. Estimating Benzathine Penicillin Need for the Treatment of Pregnant Women Diagnosed with Syphilis during Antenatal Care in High-Morbidity Countries.

    PubMed

    Taylor, Melanie M; Nurse-Findlay, Stephen; Zhang, Xiulei; Hedman, Lisa; Kamb, Mary L; Broutet, Nathalie; Kiarie, James

    2016-01-01

    Congenital syphilis continues to be a preventable cause of global stillbirth and neonatal morbidity and mortality. Shortages of injectable penicillin, the only recommended treatment for pregnant women and infants with syphilis, have been reported by high-morbidity countries. We sought to estimate current and projected annual needs for benzathine penicillin in antenatal care settings for 30 high morbidity countries that account for approximately 33% of the global burden of congenital syphilis. Proportions of antenatal care attendance, syphilis screening coverage in pregnancy, syphilis prevalence among pregnant women, and adverse pregnancy outcomes due to untreated maternal syphilis reported to WHO were applied to 2012 birth estimates for 30 high syphilis burden countries to estimate current and projected benzathine penicillin need for prevention of congenital syphilis. Using current antenatal care syphilis screening coverage and seroprevalence, we estimated the total number of women requiring treatment with at least one injection of 2.4 MU of benzathine penicillin in these 30 countries to be 351,016. Syphilis screening coverage at or above 95% for all 30 countries would increase the number of women requiring treatment with benzathine penicillin to 712,030. Based on WHO management guidelines, 351,016 doses of weight-based benzathine penicillin would also be needed for the live-born infants of mothers who test positive and are treated for syphilis in pregnancy. Assuming availability of penicillin and provision of treatment for all mothers diagnosed with syphilis, an estimated 95,938 adverse birth outcomes overall would be prevented including 37,822 stillbirths, 15,814 neonatal deaths, and 34,088 other congenital syphilis cases. Penicillin need for maternal and infant syphilis treatment is high among this group of syphilis burdened countries. Initiatives to ensure a stable and adequate supply of benzathine penicillin for treatment of maternal syphilis are important for congenital syphilis prevention, and will be increasingly critical in the future as more countries move toward elimination targets.

  19. Coverage of Nutrition Interventions Intended for Infants and Young Children Varies Greatly across Programs: Results from Coverage Surveys in 5 Countries.

    PubMed

    Leyvraz, Magali; Aaron, Grant J; Poonawala, Alia; van Liere, Marti J; Schofield, Dominic; Myatt, Mark; Neufeld, Lynnette M

    2017-05-01

    Background: The efficacy of a number of interventions that include fortified complementary foods (FCFs) or other products to improve infant and young child feeding (IYCF) is well established. Programs that provide such products free or at a subsidized price are implemented in many countries around the world. Demonstrating the impact at scale of these programs has been challenging, and rigorous information on coverage and utilization is lacking. Objective: The objective of this article is to review key findings from 11 coverage surveys of IYCF programs distributing or selling FCFs or micronutrient powders in 5 countries. Methods: Programs were implemented in Ghana, Cote d'Ivoire, India, Bangladesh, and Vietnam. Surveys were implemented at different stages of program implementation between 2013 and 2015. The Fortification Assessment Coverage Toolkit (FACT) was developed to assess 3 levels of coverage (message: awareness of the product; contact: use of the product ≥1 time; and effective: regular use aligned with program-specific goals), as well as barriers and factors that facilitate coverage. Analyses included the coverage estimates, as well as an assessment of equity of coverage between the poor and nonpoor, and between those with poor and adequate child feeding practices. Results: Coverage varied greatly between countries and program models. Message coverage ranged from 29.0% to 99.7%, contact coverage from 22.6% to 94.4%, and effective coverage from 0.8% to 88.3%. Beyond creating awareness, programs that achieved high coverage were those with effective mechanisms in place to overcome barriers for both supply and demand. Conclusions: Variability in coverage was likely due to the program design, delivery model, quality of implementation, and product type. Measuring program coverage and understanding its determinants is essential for program improvement and to estimate the potential for impact of programs at scale. Use of the FACT can help overcome this evidence gap.

  20. Coverage of Nutrition Interventions Intended for Infants and Young Children Varies Greatly across Programs: Results from Coverage Surveys in 5 Countries123

    PubMed Central

    Aaron, Grant J; Poonawala, Alia; van Liere, Marti J; Schofield, Dominic; Myatt, Mark

    2017-01-01

    Background: The efficacy of a number of interventions that include fortified complementary foods (FCFs) or other products to improve infant and young child feeding (IYCF) is well established. Programs that provide such products free or at a subsidized price are implemented in many countries around the world. Demonstrating the impact at scale of these programs has been challenging, and rigorous information on coverage and utilization is lacking. Objective: The objective of this article is to review key findings from 11 coverage surveys of IYCF programs distributing or selling FCFs or micronutrient powders in 5 countries. Methods: Programs were implemented in Ghana, Cote d’Ivoire, India, Bangladesh, and Vietnam. Surveys were implemented at different stages of program implementation between 2013 and 2015. The Fortification Assessment Coverage Toolkit (FACT) was developed to assess 3 levels of coverage (message: awareness of the product; contact: use of the product ≥1 time; and effective: regular use aligned with program-specific goals), as well as barriers and factors that facilitate coverage. Analyses included the coverage estimates, as well as an assessment of equity of coverage between the poor and nonpoor, and between those with poor and adequate child feeding practices. Results: Coverage varied greatly between countries and program models. Message coverage ranged from 29.0% to 99.7%, contact coverage from 22.6% to 94.4%, and effective coverage from 0.8% to 88.3%. Beyond creating awareness, programs that achieved high coverage were those with effective mechanisms in place to overcome barriers for both supply and demand. Conclusions: Variability in coverage was likely due to the program design, delivery model, quality of implementation, and product type. Measuring program coverage and understanding its determinants is essential for program improvement and to estimate the potential for impact of programs at scale. Use of the FACT can help overcome this evidence gap. PMID:28404839

  1. SU-F-J-194: Development of Dose-Based Image Guided Proton Therapy Workflow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pham, R; Sun, B; Zhao, T

    Purpose: To implement image-guided proton therapy (IGPT) based on daily proton dose distribution. Methods: Unlike x-ray therapy, simple alignment based on anatomy cannot ensure proper dose coverage in proton therapy. Anatomy changes along the beam path may lead to underdosing the target, or overdosing the organ-at-risk (OAR). With an in-room mobile computed tomography (CT) system, we are developing a dose-based IGPT software tool that allows patient positioning and treatment adaption based on daily dose distributions. During an IGPT treatment, daily CT images are acquired in treatment position. After initial positioning based on rigid image registration, proton dose distribution is calculatedmore » on daily CT images. The target and OARs are automatically delineated via deformable image registration. Dose distributions are evaluated to decide if repositioning or plan adaptation is necessary in order to achieve proper coverage of the target and sparing of OARs. Besides online dose-based image guidance, the software tool can also map daily treatment doses to the treatment planning CT images for offline adaptive treatment. Results: An in-room helical CT system is commissioned for IGPT purposes. It produces accurate CT numbers that allow proton dose calculation. GPU-based deformable image registration algorithms are developed and evaluated for automatic ROI-delineation and dose mapping. The online and offline IGPT functionalities are evaluated with daily CT images of the proton patients. Conclusion: The online and offline IGPT software tool may improve the safety and quality of proton treatment by allowing dose-based IGPT and adaptive proton treatments. Research is partially supported by Mevion Medical Systems.« less

  2. SU-E-T-27: A Dosimetric Evaluation of Boney Anatomy Versus Fiducial Marker Alignment for the Treatment of Prostate Cancer Using Scanned Beam Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freund, D; Ding, X; Zhang, J

    Purpose: In prostate proton radiotherapy, three fiducial markers are used for patient daily alignment. However fiducial alignment can change beamline heterogeneity in proton therapy. The purpose of this study is to determine the difference in fiducial and boney anatomy alignment for patient treatment. Methods and materials: Prostate cancer patients who received proton treatment were included in this study. 3 fiducial markers were implanted before the initial CT. All the patients were re-CT’d every 2 weeks to check the fiducial marker position reproducibility as well as dosimetric consistence of target coverage. In geometry study, re-CT were fused to the initial CTmore » base on the boney anatomy and the average fiducial marker displacement was measured the centers of the fiducials. Dosimetrically, the initial plan was recalculated directly to re-CT image set based on the boney alignment and fiducial alignment to determine the difference from daily treatment. Prostate coverage and hotspots were evaluated using the dose to 98% of the CTV (D98) and dose to 2% (D2), respectively. Results: The shift from the initial 6 patient CT image sets resulted in an average change in the fiducial location of 5.70 +/− 3 mm. Dosimetric comparison from a single patient revealed that differences from the planned dose resulted from both boney and fiducial alignment. Planned clinical treatment volume coverage resulted in a D98 of 70.44Gy and D2 of 70.84Gy compared to a D98 of 70.13Gy and D2 70.94Gy for boney alignment and a D98 of 70.08Gy and D2 71.18Gy for fiducial alignment respectively. Conclusion: This study demonstrates that with boney anatomy alignment there is little change to CTV coverage and only slightly worse CTV coverage and hotspot production with fiducial alignment. An increase patient cohort and further investigation is necessary to determine the whether boney alignment can help better control dose heterogeneity.« less

  3. A novel two-step optimization method for tandem and ovoid high-dose-rate brachytherapy treatment for locally advanced cervical cancer.

    PubMed

    Sharma, Manju; Fields, Emma C; Todor, Dorin A

    2015-01-01

    To present a novel method allowing fast volumetric optimization of tandem and ovoid high-dose-rate treatments and to quantify its benefits. Twenty-seven CT-based treatment plans from 6 consecutive cervical cancer patients treated with four to five intracavitary tandem and ovoid insertions were used. Initial single-step optimized plans were manually optimized, approved, and delivered plans created with a goal to cover high-risk clinical target volume (HR-CTV) with D90 >90% and minimize rectum, bladder, and sigmoid D2cc. For the two-step optimized (TSO) plan, each single-step optimized plan was replanned adding a structure created from prescription isodose line to the existent physician delineated HR-CTV, rectum, bladder, and sigmoid. New, more rigorous dose-volume histogram constraints for the critical organs at risks (OARs) were used for the optimization. HR-CTV D90 and OAR D2ccs were evaluated in both plans. TSO plans had consistently smaller D2ccs for all three OARs while preserving HR-CTV D90. On plans with "excellent" CTV coverage, average D90 of 96% (91-102%), sigmoid, bladder, and rectum D2cc, respectively, reduced on average by 37% (16-73%), 28% (20-47%), and 27% (15-45%). Similar reductions were obtained on plans with "good" coverage, average D90 of 93% (90-99%). For plans with "inferior" coverage, average D90 of 81%, the coverage increased to 87% with concurrent D2cc reductions of 31%, 18%, and 11% for sigmoid, bladder, and rectum, respectively. The TSO can be added with minimal planning time increase but with the potential of dramatic and systematic reductions in OAR D2ccs and in some cases with concurrent increase in target dose coverage. These single-fraction modifications would be magnified over the course of four to five intracavitary insertions and may have real clinical implications in terms of decreasing both acute and late toxicities. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  4. Vaccination coverage among social and healthcare workers in ten countries of Samu-social international sites.

    PubMed

    Marshall, Esaie; Salmon, Dominique; Bousfiha, Nadia; Togola, Yacouba; Ouedraogo, François; Santantonio, Maud; Dieng, Coumba Khadidja; Tartière, Suzanne; Emmanuelli, Xavier

    2017-09-18

    We aim to determine the vaccination coverage of social and healthcare workers in International sites of Samusocial, providing emergency care to homeless people, and to assess factors associated with having received necessary doses at adulthood. Data on immunization coverage of social and healthcare workers were provided by a cross-sectional survey, conducted from February to April 2015 among 252 Samusocial workers in 10 countries. Vaccination status and characteristics of participants were collected through a self-administered questionnaire. Prevalence rate ratio (PRR) of vaccination status was calculated using Poisson regression models. Among 252 Samusocial social and health workers who felt a questionnaire, median age was 39years, 42.1% were female, 88.9% were in contact with homeless beneficiaries (19.1% health workers). Overall, 90.1% of Samusocial staff felt adult vaccinations was useful and 70.2% wished to receive booster doses in future. Vaccination coverage at adulthood was satisfactory for diphtheria and poliomyelitis (96%), but low for influenza (20.8%), meningococcus (50.5%), hepatitis B (56.3%), yellow fever (58.1%), measles (81.3%) and pertussis (90.7%). The main reasons for not having received vaccination booster doses were forgetting the dates of booster doses (38.4%) and not having received the information (13.5%). In adjusted analysis, prevalence of up-to-date for vaccination schedule was 35% higher among health workers than among social workers (aPRR=1.35, 95%CI: 1.01-1.82, P=0.05) and was 56% higher among workers who had a documentary evidence of vaccination than in those who did not (aPRR=1.56, 95%CI: 1.19-2.02, P=0.001). The Samusocial International workers vaccine coverage at adulthood was insufficient and disparate by region. It is necessary to strengthen the outreach of this staff and increase immunization policy for hepatitis B, diphtheria, tetanus, and measles, as well as for yellow fever, rabies and meningococcal ACYW135 vaccines in at risk regions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chau, Ricky; Teo, Peter; Kam, Michael

    The aim of this study is to evaluate the deficiencies in target coverage and organ protection of 2-dimensional radiation therapy (2DRT) in the treatment of advanced T-stage (T3-4) nasopharyngeal carcinoma (NPC), and assess the extent of improvement that could be achieved with intensity modulated radiation therapy (IMRT), with special reference to of the dose to the planning organ-at-risk volume (PRV) of the brainstem and spinal cord. A dosimetric study was performed on 10 patients with advanced T-stage (T3-4 and N0-2) NPC. Computer tomography (CT) images of 2.5-mm slice thickness of the head and neck were acquired with the patient immobilizedmore » in semi-extended-head position. A 2D plan based on Ho's technique, and an IMRT plan based on a 7-coplanar portals arrangement, were established for each patient. 2DRT was planned with the field borders and shielding drawn on the simulator radiograph with reference to bony landmarks, digitized, and entered into a planning computer for reconstruction of the 3D dose distribution. The 2DRT and IMRT treatment plans were evaluated and compared with respect to the dose-volume histograms (DVHs) of the targets and the organs-at-risk (OARs), tumor control probability (TCP), and normal tissue complication probabilities (NTCPs). With IMRT, the dose coverage of the target was superior to that of 2DRT. The mean minimum dose of the GTV and PTV were increased from 33.7 Gy (2DRT) to 62.6 Gy (IMRT), and 11.9 Gy (2DRT) to 47.8 Gy (IMRT), respectively. The D{sub 95} of the GTV and PTV were also increased from 57.1 Gy (2DRT) to 67 Gy (IMRT), and 45 Gy (2DRT) to 63.6 Gy (IMRT), respectively. The TCP was substantially increased to 78.5% in IMRT. Better protection of the critical normal organs was also achieved with IMRT. The mean maximum dose delivered to the brainstem and spinal cord were reduced significantly from 61.8 Gy (2DRT) to 52.8 Gy (IMRT) and 56 Gy (2DRT) to 43.6 Gy (IMRT), respectively, which were within the conventional dose limits of 54 Gy for brainstem and of 45 Gy for spinal cord. The mean maximum doses deposited on the PRV of the brainstem and spinal cord were 60.7 Gy and 51.6 Gy respectively, which were above the conventional dose limits. For the chiasm, the mean dose maximum and the dose to 5% of its volume were reduced from 64.3 Gy (2DRT) to 53.7 Gy (IMRT) and from 62.8 Gy (2DRT) to 48.7 Gy (IMRT), respectively, and the corresponding NTCP was reduced from 18.4% to 2.1%. For the temporal lobes, the mean dose to 10% of its volume (about 4.6 cc) was reduced from 63.8 Gy (2DRT) to 55.4 Gy (IMRT) and the NTCP was decreased from 11.7% to 3.4%. The therapeutic ratio for T3-4 NPC tumors can be significantly improved with IMRT treatment technique due to improvement both in target coverage and the sparing of the critical normal organ. Although the maximum doses delivered to the brainstem and spinal cord in IMRT can be kept at or below their conventional dose limits, the maximum doses deposited on the PRV often exceed these limits due to the close proximity between the target and OARs. In other words, ideal dosimetric considerations cannot be fulfilled in IMRT planning for T3-4 NPC tumors. A compromise of the maximal dose limit to the PRV of the brainstem and spinal cord would need be accepted if dose coverage to the targets is not to be unacceptably compromised. Dosimetric comparison with 2DRT plans show that these dose limits to PRV were also frequently exceeded in 2DRT plans for locally advanced NPC. A dedicated retrospective study on the incidence of clinical injury to neurological organs in a large series of patients with T3-4 NPC treated by 2DRT may provide useful reference data in exploring how far the PRV dose constraints may be relaxed, to maximize the target coverage without compromising the normal organ function.« less

  6. Volumetric-modulated arc therapy for the treatment of a large planning target volume in thoracic esophageal cancer.

    PubMed

    Abbas, Ahmar S; Moseley, Douglas; Kassam, Zahra; Kim, Sun Mo; Cho, Charles

    2013-05-06

    Recently, volumetric-modulated arc therapy (VMAT) has demonstrated the ability to deliver radiation dose precisely and accurately with a shorter delivery time compared to conventional intensity-modulated fixed-field treatment (IMRT). We applied the hypothesis of VMAT technique for the treatment of thoracic esophageal carcinoma to determine superior or equivalent conformal dose coverage for a large thoracic esophageal planning target volume (PTV) with superior or equivalent sparing of organs-at-risk (OARs) doses, and reduce delivery time and monitor units (MUs), in comparison with conventional fixed-field IMRT plans. We also analyzed and compared some other important metrics of treatment planning and treatment delivery for both IMRT and VMAT techniques. These metrics include: 1) the integral dose and the volume receiving intermediate dose levels between IMRT and VMATI plans; 2) the use of 4D CT to determine the internal motion margin; and 3) evaluating the dosimetry of every plan through patient-specific QA. These factors may impact the overall treatment plan quality and outcomes from the individual planning technique used. In this study, we also examined the significance of using two arcs vs. a single-arc VMAT technique for PTV coverage, OARs doses, monitor units and delivery time. Thirteen patients, stage T2-T3 N0-N1 (TNM AJCC 7th edn.), PTV volume median 395 cc (range 281-601 cc), median age 69 years (range 53 to 85), were treated from July 2010 to June 2011 with a four-field (n = 4) or five-field (n = 9) step-and-shoot IMRT technique using a 6 MV beam to a prescribed dose of 50 Gy in 20 to 25 F. These patients were retrospectively replanned using single arc (VMATI, 91 control points) and two arcs (VMATII, 182 control points). All treatment plans of the 13 study cases were evaluated using various dose-volume metrics. These included PTV D99, PTV D95, PTV V9547.5Gy(95%), PTV mean dose, Dmax, PTV dose conformity (Van't Riet conformation number (CN)), mean lung dose, lung V20 and V5, liver V30, and Dmax to the spinal canal prv3mm. Also examined were the total plan monitor units (MUs) and the beam delivery time. Equivalent target coverage was observed with both VMAT single and two-arc plans. The comparison of VMATI with fixed-field IMRT demonstrated equivalent target coverage; statistically no significant difference were found in PTV D99 (p = 0.47), PTV mean (p = 0.12), PTV D95 and PTV V9547.5Gy (95%) (p = 0.38). However, Dmax in VMATI plans was significantly lower compared to IMRT (p = 0.02). The Van't Riet dose conformation number (CN) was also statistically in favor of VMATI plans (p = 0.04). VMATI achieved lower lung V20 (p = 0.05), whereas lung V5 (p = 0.35) and mean lung dose (p = 0.62) were not significantly different. The other OARs, including spinal canal, liver, heart, and kidneys showed no statistically significant differences between the two techniques. Treatment time delivery for VMATI plans was reduced by up to 55% (p = 5.8E-10) and MUs reduced by up to 16% (p = 0.001). Integral dose was not statistically different between the two planning techniques (p = 0.99). There were no statistically significant differences found in dose distribution of the two VMAT techniques (VMATI vs. VMATII) Dose statistics for both VMAT techniques were: PTV D99 (p = 0.76), PTV D95 (p = 0.95), mean PTV dose (p = 0.78), conformation number (CN) (p = 0.26), and MUs (p = 0.1). However, the treatment delivery time for VMATII increased significantly by two-fold (p = 3.0E-11) compared to VMATI. VMAT-based treatment planning is safe and deliverable for patients with thoracic esophageal cancer with similar planning goals, when compared to standard IMRT. The key benefit for VMATI was the reduction in treatment delivery time and MUs, and improvement in dose conformality. In our study, we found no significant difference in VMATII over single-arc VMATI for PTV coverage or OARs doses. However, we observed significant increase in delivery time for VMATII compared to VMATI.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumaran Nair, C; Hoffman, D; Wright, C

    Purpose: We aim to evaluate a new commercial dose mimicking inverse-planning application that was designed to provide cross-platform treatment planning, for its dosimetric quality and efficiency. The clinical benefit of this application allows patients treated on O-shaped linac to receive an equivalent plan on conventional L-shaped linac as needed for workflow or machine downtime. Methods: The dose mimicking optimization process seeks to create a similar DVH of an O-shaped linac-based plans with an alternative treatment technique (IMRT or VMAT), by maintaining target conformity, and penalizing dose falloff outside the target. Ten head and neck (HN) helical delivery plans, including simplemore » and complex cases were selected for re-planning with the dose mimicking application. All plans were generated for a 6 MV beam model, using 7-field/ 9-field IMRT and VMAT techniques. PTV coverage (D1, D99 and homogeneity index [HI]), and OARs avoidance (Dmean / Dmax) were compared. Results: The resulting dose mimicked HN plans achieved acceptable PTV coverage for HI (VMAT 7.0±2.3, 7-fld 7.3±2.4, and 9-fld 7.0±2.4), D99 (98.0%±0.7%, 97.8%±0.7%, and 98.0%±0.7%), as well as D1 (106.4%±2.1%, 106.5%±2.2%, and 106.4%±2.1%), respectively. The OAR dose discrepancy varied: brainstem (2% to 4%), cord (3% to 6%), esophagus (−4% to −8%), larynx (−4% to 2%), and parotid (4% to 14%). Mimicked plans would typically be needed for 1–5 fractions of a treatment course, and we estimate <1% variance would be introduced in target coverage while maintaining comparable low dose to OARs. All mimicked plans were approved by independent physician and passed patient specific QA within our established tolerance. Conclusion: Dose mimicked plans provide a practical alternative for responding to clinical workflow issues, and provide reliability for patient treatment. The quality of dose mimicking for HN patients highly depends on the delivery technique, field numbers and angles, as well as user selection of structures.« less

  8. SU-E-T-216: Comparison of Volumetrically Modulated Arc Therapy Treatment Using Flattening Filter Free Beams Vs. Flattened Beams for Partial Brain Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, S; Roa, D; Hanna, N

    2015-06-15

    Purpose: Flattening Filter Free (FFF) beams offer the potential for higher dose rates, short treatment time, and lower out of field dose. Therefore, the aim of this study was to investigate the dosimetric effects and out of field dose of Volumetric Modulated Arc Therapy (VMAT) plans using FFF vs Flattening Filtering (FF) beams for partial brain irradiation. Methods: Ten brain patients treated with a 6FF beam from a Truebeam STX were analyzed retrospectively for this study. These plans (46Gy at 2 Gy per fraction) were re-optimized for 6FFF beams using the same dose constraints as the original plans. PTV coverage,more » PTV Dmax, total MUs, and mean dose to organs-at-risk (OAR) were evaluated. In addition, the out-of-field dose for 6FF and 6FFF plans for one patient was measured on an anthropomorphic phantom. TLDs were placed inside (central axis) and outside (surface) the phantom at distances ranging from 0.5 cm to 17 cm from the field edge. Paired T-test was used for statistical analysis. Results: PTV coverage and PTV Dmax were comparable for the FF and FFF plans with 95.9% versus 95.6% and 111.2% versus 111.9%, respectively. Mean dose to the OARs were 3.7% less for FFF than FF plans (p<0.0001). Total MUs were, on average, 12.5% greater for FFF than FF plans with 481±55 MU (FFF) versus 429±50 MU (FF), p=0.0003. On average, the measured out of field dose was 24% less for FFF compared to FF, p<0.0001. A similar beam-on time was observed for the FFF and FF treatment. Conclusion: It is beneficial to use 6FFF beams for regular fractionated brain VMAT treatments. VMAT treatment plans using FFF beams can achieve comparable PTV coverage but with more OAR sparing. The out of field dose is significant less with mean reduction of 24%.« less

  9. Dynamic simulation of motion effects in IMAT lung SBRT.

    PubMed

    Zou, Wei; Yin, Lingshu; Shen, Jiajian; Corradetti, Michael N; Kirk, Maura; Munbodh, Reshma; Fang, Penny; Jabbour, Salma K; Simone, Charles B; Yue, Ning J; Rengan, Ramesh; Teo, Boon-Keng Kevin

    2014-11-01

    Intensity modulated arc therapy (IMAT) has been widely adopted for Stereotactic Body Radiotherapy (SBRT) for lung cancer. While treatment dose is optimized and calculated on a static Computed Tomography (CT) image, the effect of the interplay between the target and linac multi-leaf collimator (MLC) motion is not well described and may result in deviations between delivered and planned dose. In this study, we investigated the dosimetric consequences of the inter-play effect on target and organs at risk (OAR) by simulating dynamic dose delivery using dynamic CT datasets. Fifteen stage I non-small cell lung cancer (NSCLC) patients with greater than 10 mm tumor motion treated with SBRT in 4 fractions to a dose of 50 Gy were retrospectively analyzed for this study. Each IMAT plan was initially optimized using two arcs. Simulated dynamic delivery was performed by associating the MLC leaf position, gantry angle and delivered beam monitor units (MUs) for each control point with different respiratory phases of the 4D-CT using machine delivery log files containing time stamps of the control points. Dose maps associated with each phase of the 4D-CT dose were calculated in the treatment planning system and accumulated using deformable image registration onto the exhale phase of the 4D-CT. The original IMAT plans were recalculated on the exhale phase of the CT for comparison with the dynamic simulation. The dose coverage of the PTV showed negligible variation between the static and dynamic simulation. There was less than 1.5% difference in PTV V95% and V90%. The average inter-fraction and cumulative dosimetric effects among all the patients were less than 0.5% for PTV V95% and V90% coverage and 0.8 Gy for the OARs. However, in patients where target is close to the organs, large variations were observed on great vessels and bronchus for as much as 4.9 Gy and 7.8 Gy. Limited variation in target dose coverage and OAR constraints were seen for each SBRT fraction as well as over all four fractions. Large dose variations were observed on critical organs in patients where these organs were closer to the target.

  10. SU-E-T-25: A Dosimetric Comparison of Three-Dimension Conformal and Intensity-Modulated Radiation Therapy in Esophageal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gallardo, N; Maneru, F; Fuentemilla, N

    2015-06-15

    Purpose: dosimetric comparison of 3DCRT and IMRT in 9 esophageal cancer. The aim of this paper is to know which of these two techniques is dosimetrically more favorable dosimetrically at both the CTV coverage and dose obtained in the relevant organs at risk, in this case, lungs and heart, as the spinal cord received in all cases below 45 Gy. Methods: we chose 9 patients from our center (CHN) with the same type of esophageal cancer and in which the prescribed dose was the same, 54 Gy. For these treatments we have used the same fields and the same anglesmore » (AP (0 °), OPD (225°–240°) and OPI (125°–135°)).All plans have been implemented using Eclipse (version 11.0) with AAA( Analytical Anisotropic Algorithm )(Version 11.0.31). Results: To analyze the coverage of the CTV, we have evaluated the D99% and found that the average dose received by 99% of CTV with IMRT is 53.8 ± 0.4 Gy (99.6% of the prescribed dose) and the mean value obtained with 3DCRT is 52.3 ± 0.6 Gy (96.8% of the prescribed dose).The last data analyzed was the D2% of PTV, a fact that gives us information on the maximum dose received by our PTV. D2% of the PTV for IMRT planning is 55.4 ± 0.4 Gy (102.6% of the prescribed dose) and with 3DCRT is 56.8 ± 0.7 Gy (105.2% of the prescribed dose).All parameters analyzed at risk organs (V30, V40, V45 and V50 for the case of heart and V5, V10, V15 and V20 for the case of the lungs) provide us irradiated volume percentages lower in IMRT than 3DCRT. Conclusion: IMRT provides a considerable improvement in the coverage of the CTV and the doses to organs at risk.« less

  11. SU-E-T-513: Investigating Dose of Internal Target Volume After Correcting for Tissue Heterogeneity in SBRT Lung Plans with Homogeneity Calculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qi, P; Zhuang, T; Magnelli, A

    2015-06-15

    Purpose It was recommended to use the prescription of 54 Gy/3 with heterogeneity corrections for previously established dose scheme of 60 Gy/3 with homogeneity calculation. This study is to investigate dose coverage for the internal target volume (ITV) with and without heterogeneity correction. Methods Thirty patients who received stereotactic body radiotherapy (SBRT) to a dose of 60 Gy in 3 fractions with homogeneous planning for early stage non-small-cell lung cancer (NSCLC) were selected. ITV was created either from 4DCT scans or a fusion of multi-phase respiratory scans. Planning target volume (PTV) was a 5 mm expansion of the ITV. Formore » this study, we recalculated homogeneous clinical plans using heterogeneity corrections with monitor units set as clinically delivered. All plans were calculated with 3 mm dose grids and collapsed cone convolution algorithm. To account for uncertainties from tumor delineation and image-guided radiotherapy, a structure ITV2mm was created by expanding ITV with 2 mm margins. Dose coverage to the PTV, ITV and ITV2mm were compared with a student paired t-test. Results With heterogeneity corrections, the PTV V60Gy decreased by 10.1% ± 18.4% (p<0.01) while the maximum dose to the PTV increased by 3.7 ± 4.3% (p<0.01). With and without corrections, D99% was 65.8 ± 4.0 Gy and 66.7 ± 4.8 Gy (p=0.15) for the ITV, and 63.9 ± 3.4 Gy and 62.9 ± 4.6 Gy for the ITV2mm (p=0.22), respectively. The mean dose to the ITV and ITV2mm increased 3.6% ± 4.7% (p<0.01) and 2.3% ± 5.2% (p=0.01) with heterogeneity corrections. Conclusion After heterogeneity correction, the peripheral coverage of the PTV decreased to approximately 54 Gy, but D99% of the ITV and ITV2mm was unchanged and the mean dose to the ITV and ITV2mm was increased. Clinical implication of these results requires more investigation.« less

  12. Seasonal influenza vaccine dose distribution in 195 countries (2004-2013): Little progress in estimated global vaccination coverage.

    PubMed

    Palache, Abraham; Oriol-Mathieu, Valerie; Fino, Mireli; Xydia-Charmanta, Margarita

    2015-10-13

    Seasonal influenza is an important disease which results in 250,000-500,000 annual deaths worldwide. Global targets for vaccination coverage rates (VCRs) in high-risk groups are at least 75% in adults ≥65 years and increased coverage in other risk groups. The International Federation of Pharmaceutical Manufacturers and Associations Influenza Vaccine Supply (IFPMA IVS) International Task Force developed a survey methodology in 2008, to assess the global distribution of influenza vaccine doses as a proxy for VCRs. This paper updates the previous survey results on absolute numbers of influenza vaccine doses distributed between 2004 and 2013 inclusive, and dose distribution rates per 1000 population, and provides a qualitative assessment of the principal enablers and barriers to seasonal influenza vaccination. The two main findings from the quantitative portion of the survey are the continued negative trend for dose distribution in the EURO region and the perpetuation of appreciable differences in scale of dose distribution between WHO regions, with no observed convergence in the rates of doses distributed per 1000 population over time. The main findings from the qualitative portion of the survey were that actively managing the vaccination program in real-time and ensuring political commitment to vaccination are important enablers of vaccination, whereas insufficient access to vaccination and lack of political commitment to seasonal influenza vaccination programs are likely contributing to vaccination target failures. In all regions of the world, seasonal influenza vaccination is underutilized as a public health tool. The survey provides evidence of lost opportunity to protect populations against potentially serious influenza-associated disease. We call on the national and international public health communities to re-evaluate their political commitment to the prevention of the annual influenza disease burden and to develop a systematic approach to improve vaccine distribution equitably. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. SU-F-T-519: Is Geometry Based Setup Sufficient for All of the Head and Neck Treatment Cases?: A Feasibility Study Towards the Dose Based Setup

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, S; Chen, S; Zhang, B

    Purpose: This study compares the geometric-based setup (GBS) which is currently used in the clinic to a novel concept of dose-based setup (DBS) of head and neck (H&N) patients using cone beam CT (CBCT) of the day; and evaluates the clinical advantages. Methods: Ten H&N patients who underwent re-simulation and re-plan due to noticeable anatomic changes during the course of the treatments were retrospectively reviewed on dosimetric changes in the assumption of no plan modification was performed. RayStation planning system (RaySearch Laboratories AB, Sweden) was used to match (ROI fusion module) between prescribed isodoseline (IDL) in the CBCT imported alongmore » with ROIs from re-planned CT and the IDL of original plan (Dose-based setup: DBS). Then, the CBCT plan based on daily setup using the GBS (previously used for a patient) and the DBS CBCT plan recalculated in RayStation compared against the original CT-sim plan. Results: Most of patients’ tumor coverage and OAR doses got generally worsen when the CBCT plans were compared with original CT-sim plan with GBS. However, when DBS intervened, the OAR dose and tumor coverage was better than the GBS. For example, one of patients’ daily average doses of right parotid and oral cavity increased to 26% and 36%, respectively from the original plan to the GBS planning. However, it only increased by 13% and 24%, respectively with DBS. GTV D95 coverage also decreased by 16% with GBS, but only 2% decreased with DBS. Conclusion: DBS method is superior to GBS to prevent any abrupt dose changes to OARs as well as PTV/CTV or GTV at least for some H&N cases. Since it is not known when the DBS is beneficial to the GBS, a system which enables the on-line DBS may be helpful for better treatment of H&N.« less

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, H; Cape Breton Cancer Centre, Sydney, NS

    Purpose: To perform the comparison of dose distributions and dosevolume- histograms generated by VMAT and conventional field-in-field technique for left-sided breast and chestwall cancers; to determine whether VMAT offers more dosimetric benefits than does the field-in-field technique. Methods: All VMAT and field-in-filed plans were produced in Eclipse(version 10). Five plans were generated for left-sided breast and leftsided chestwall with supraclavicular nodes, respectively. A clockwise arc (CW) and a counter-clockwise arc (CCW) were used with start and stop angles being 310o±10o and 140o±10o. Collimator angles were 30o for CW and 330o for CCW. The conformity index (CI) is the ratio ofmore » V95% over PTV. The homogeneity index (HI) is the ratio of the difference between D2% and D98% over the prescribed dose. The V5, as an indicator of low dose bath to organs-at-risk, was used for ipsilateral lung, heart, contralateral lung, and contralateral breast. The V20, as an indicator of radiation pneumonitis, was used for ipsilateral lung. Results: Breast/chestwall VMAT delivers much higher low dose bath to ipsilateral lung, contralateral lung and contralateral breast/chestwall for both intact breast and chestwall with nodes. V5 for heart is increased in VMAT plans. V20 for ipsilateral lung is lower in VMAT plans. PTV coverage is similar for both techniques. For one particular chestwall patient with supraclavicular and internal mammary nodes, VMAT offers superior dose coverage of PTVs with slightly more low-dose-wash to heart, contralateral lung and contralateral breast. Conclusion: This study indicates that there is generally no benefit using VMAT for left-sided intact breast, due to large low-dose-bath (5Gy) to normal tissues with insignificant improvement in PTV coverage. Dosimetric benefits will be seen in VMAT plans for some chestwall patients with large size, and/or internal mammary nodes, etc. Whether a chestwall patient is treated with VMAT should be carefully analyzed on an individual basis.« less

  15. 20 CFR 722.4 - The Secretary's list.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false The Secretary's list. 722.4 Section 722.4... ADEQUATE COVERAGE FOR PNEUMOCONIOSIS AND LISTING OF APPROVED STATE LAWS § 722.4 The Secretary's list. (a) The Secretary has determined that publication of the Secretary's list in the Code of Federal...

  16. 3 CFR 8609 - Proclamation 8609 of November 30, 2010. World AIDS Day, 2010

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... orientation, gender identity, or socio-economic circumstance—will have unfettered access to high-quality, life... have endured great difficulties in obtaining adequate health insurance coverage and quality care. The... continue to focus on saving lives through effective prevention activities, as well as other smart...

  17. Trial by Fire (and Tornado) Taught Us to Plan for Crises.

    ERIC Educational Resources Information Center

    Caylor, Mary Jane

    1991-01-01

    Based on Huntsville (Alabama) schools' experience with a devastating fire, the superintendent later ensured adequate fire insurance coverage, promoted regular fire drills, and developed an emergency response plan that delineated staff responsibilities, communication modes, and training and updating procedures. The plan served the district well…

  18. 42 CFR 488.18 - Documentation of findings.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... conditions of participation, requirements (for SNFs and NFs), or conditions for coverage must be adequately... with the conditions or requirements (for SNFs and NFs), and therefore not eligible to participate in... requirements (for SNFs and NFs) or as meeting the requirements for special certification (see § 488.54), with...

  19. 42 CFR 488.18 - Documentation of findings.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... conditions of participation, requirements (for SNFs and NFs), or conditions for coverage must be adequately... with the conditions or requirements (for SNFs and NFs), and therefore not eligible to participate in... requirements (for SNFs and NFs) or as meeting the requirements for special certification (see § 488.54), with...

  20. 42 CFR 488.18 - Documentation of findings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... conditions of participation, requirements (for SNFs and NFs), or conditions for coverage must be adequately... with the conditions or requirements (for SNFs and NFs), and therefore not eligible to participate in... requirements (for SNFs and NFs) or as meeting the requirements for special certification (see § 488.54), with...

  1. 42 CFR 488.18 - Documentation of findings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... conditions of participation, requirements (for SNFs and NFs), or conditions for coverage must be adequately... with the conditions or requirements (for SNFs and NFs), and therefore not eligible to participate in... requirements (for SNFs and NFs) or as meeting the requirements for special certification (see § 488.54), with...

  2. 42 CFR 488.18 - Documentation of findings.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... conditions of participation, requirements (for SNFs and NFs), or conditions for coverage must be adequately... with the conditions or requirements (for SNFs and NFs), and therefore not eligible to participate in... requirements (for SNFs and NFs) or as meeting the requirements for special certification (see § 488.54), with...

  3. Disease and spray coverage in pecan trees

    USDA-ARS?s Scientific Manuscript database

    Pecan scab (Fusicladium effusum G. Winter) is the major disease of pecan in the southeastern U.S., and severe epidemics on susceptible cultivars can result in complete yield loss. Anecdotal evidence indicates adequate scab control in the tops of tall trees in mature orchards is difficult, but no dat...

  4. Your Insurance Dollar. Money Management.

    ERIC Educational Resources Information Center

    Baran, Nancy H., Ed.

    This booklet provides some practical guidelines for determining total insurance needs, examining options, and comparing costs. It discusses how to fit insurance costs into an overall financial plan, the necessity of adequate liability coverage, and the importance of keeping policies up to date. The next four sections highlight the basic types of…

  5. 24 CFR 242.33 - Covenant for malpractice, fire, and other hazard insurance.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... for malpractice, fire, and other hazard insurance. The mortgage shall contain a covenant binding the mortgagor to maintain adequate liability, fire, and extended coverage insurance on the property. The... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Covenant for malpractice, fire, and...

  6. 20 CFR 722.4 - The Secretary's list.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 3 2011-04-01 2011-04-01 false The Secretary's list. 722.4 Section 722.4... PROVIDE ADEQUATE COVERAGE FOR PNEUMOCONIOSIS AND LISTING OF APPROVED STATE LAWS § 722.4 The Secretary's list. (a) The Secretary has determined that publication of the Secretary's list in the Code of Federal...

  7. APPLICATION OF A MULTIPURPOSE UNEQUAL-PROBABILITY STREAM SURVEY IN THE MID-ATLANTIC COASTAL PLAIN

    EPA Science Inventory

    A stratified random sample with unequal-probability selection was used to design a multipurpose survey of headwater streams in the Mid-Atlantic Coastal Plain. Objectives for data from the survey include unbiased estimates of regional stream conditions, and adequate coverage of un...

  8. Shape and Steepness of Toxicological Dose-Response Relationships of Continuous Endpoints

    EPA Science Inventory

    A re-analysis of a large number of historical dose-response data for continuous endpoints indicates that an exponential or a Hill model with four parameters both adequately describe toxicological dose-responses. The four parameters relate to the background response, the potency o...

  9. Determinants of geographic inequalities in HPV vaccination in the most populated region of France.

    PubMed

    Héquet, Delphine; Rouzier, Roman

    2017-01-01

    In France, there are recommendations and reimbursements for human papillomavirus (HPV) vaccination but no HPV vaccination programs. Therefore, vaccination is largely determined by parents' initiative, which can lead to inequalities. The objective of this study was to determine the factors associated with poorer vaccination coverage rates in the most populated region of France. The data of this study were obtained from the National Health Insurance between 2011 and 2013. Correlations between vaccination initiation rate (at least 1 dose reimbursed) and socio-demographic/cultural factors were assessed using Pearson's product-moment correlation coefficient. Multivariate analyses were performed using logistic regression. In total, 121,636 girls received at least one HPV vaccine dose. The vaccination rate for girls born from 1996 to 1999 was 18.7%. Disparities in vaccination coverage rates were observed between the 8 departments of the region, ranging from 12.9% to 22.6%. At the department level, unemployment, proportion of immigrants and foreigners, and coverage by CMU health insurance ("Couverture Maladie Universelle", a health insurance plan for those who are not otherwise covered through business or employment and who have a low income) were significantly inversely correlated with vaccination rates, whereas urban residence, medical density, income and use of medical services were not related to coverage. In the multivariate model, only the percentage of foreigners remained independently associated with lower vaccination coverage. At the individual level, the use of medical services was a strong driver of HPV vaccination initiation. We observed geographic disparities in HPV vaccination initiation coverage. Even if no clear factor was identified as a vaccination determinant, we observed a failure of vaccination only based on parents' initiative. Therefore, an organized policy on HPV vaccination, such as school-based programs, can help improve coverage rates.

  10. The varicella vaccination pattern among children under 5 years old in selected areas in China.

    PubMed

    Yue, Chenyan; Li, Yan; Wang, Yamin; Liu, Yan; Cao, Linsheng; Zhu, Xu; Martin, Kathryn; Wang, Huaqing; An, Zhijie

    2017-07-11

    Vaccine is the most effective way to protect susceptible children from varicella. Few published literature or reports on varicella vaccination of Chinese children exist. Thus, in order to obtain specific information on varicella vaccination of this population, we conducted this survey. We first used purposive sampling methods to select 6 provinces 10 counties from eastern, middle and western parts of China with high quality of Immunization Information Management System (IIMS), and then randomly select children from population in the IIMS, then we checked vaccination certificate on-site. Based on the varicella vaccination information collected from 481 children's vaccination certificates from all ten selected counties in China, overall coverage of the first dose of varicella vaccine was 73.6%. There is a positive linear correlation between per capita GDP and vaccine coverage at county level (r=0.929, P < 0.01). The cumulative vaccine coverage among children at 1 year, 2 years and ≥3 years old were 67.6%, 71.9% and 73.6% respectively (X2=4.53, P =0.10). The age of vaccination was mainly concentrated in 12-17 months. The coverage rate of the first dose of varicella vaccine in selected areas was lower than that recommended by WHO position paper. The coverage rate was relatively low in areas of low social-economic status. The cumulative coverage had no significant statistical difference among different age group. Most children received varicella vaccine before 3 years old. We suggest introducing the varicella vaccine into routine immunization program, to ensure universal high coverage among children in China. We also suggest that varicella vaccination information should be checked before entering school, in order to control and prevent varicella outbreaks in schools.

  11. Fully automated treatment planning for head and neck radiotherapy using a voxel-based dose prediction and dose mimicking method

    NASA Astrophysics Data System (ADS)

    McIntosh, Chris; Welch, Mattea; McNiven, Andrea; Jaffray, David A.; Purdie, Thomas G.

    2017-08-01

    Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present a probabilistic, atlas-based approach which predicts the dose for novel patients using a set of automatically selected most similar patients (atlases). The output is a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces the need to specify and tune dose-volume objectives. Voxel-based dose mimicking optimization then converts the predicted dose distribution to a complete treatment plan with dose calculation using a collapsed cone convolution dose engine. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients by evaluating 14 clinical dose evaluation criteria. Our preliminary results are promising and demonstrate that automated methods can generate comparable dose distributions to clinical. Overall, automated plans achieved an average of 0.6% higher dose for target coverage evaluation criteria, and 2.4% lower dose at the organs at risk criteria levels evaluated compared with clinical. There was no statistically significant difference detected in high-dose conformity between automated and clinical plans as measured by the conformation number. Automated plans achieved nine more unique criteria than clinical across the 12 patients tested and automated plans scored a significantly higher dose at the evaluation limit for two high-risk target coverage criteria and a significantly lower dose in one critical organ maximum dose. The novel dose prediction method with dose mimicking can generate complete treatment plans in 12-13 min without user interaction. It is a promising approach for fully automated treatment planning and can be readily applied to different treatment sites and modalities.

  12. Fully automated treatment planning for head and neck radiotherapy using a voxel-based dose prediction and dose mimicking method.

    PubMed

    McIntosh, Chris; Welch, Mattea; McNiven, Andrea; Jaffray, David A; Purdie, Thomas G

    2017-07-06

    Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present a probabilistic, atlas-based approach which predicts the dose for novel patients using a set of automatically selected most similar patients (atlases). The output is a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces the need to specify and tune dose-volume objectives. Voxel-based dose mimicking optimization then converts the predicted dose distribution to a complete treatment plan with dose calculation using a collapsed cone convolution dose engine. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients by evaluating 14 clinical dose evaluation criteria. Our preliminary results are promising and demonstrate that automated methods can generate comparable dose distributions to clinical. Overall, automated plans achieved an average of 0.6% higher dose for target coverage evaluation criteria, and 2.4% lower dose at the organs at risk criteria levels evaluated compared with clinical. There was no statistically significant difference detected in high-dose conformity between automated and clinical plans as measured by the conformation number. Automated plans achieved nine more unique criteria than clinical across the 12 patients tested and automated plans scored a significantly higher dose at the evaluation limit for two high-risk target coverage criteria and a significantly lower dose in one critical organ maximum dose. The novel dose prediction method with dose mimicking can generate complete treatment plans in 12-13 min without user interaction. It is a promising approach for fully automated treatment planning and can be readily applied to different treatment sites and modalities.

  13. Performance of the Lot Quality Assurance Sampling Method Compared to Surveillance for Identifying Inadequately-performing Areas in Matlab, Bangladesh

    PubMed Central

    Hanifi, S.M.A.; Roy, Nikhil; Streatfield, P. Kim

    2007-01-01

    This paper compared the performance of the lot quality assurance sampling (LQAS) method in identifying inadequately-performing health work-areas with that of using health and demographic surveillance system (HDSS) data and examined the feasibility of applying the method by field-level programme supervisors. The study was carried out in Matlab, the field site of ICDDR,B, where a HDSS has been in place for over 30 years. The LQAS method was applied in 57 work-areas of community health workers in ICDDR,B-served areas in Matlab during July-September 2002. The performance of the LQAS method in identifying work-areas with adequate and inadequate coverage of various health services was compared with those of the HDSS. The health service-coverage indicators included coverage of DPT, measles, BCG vaccination, and contraceptive use. It was observed that the difference in the proportion of work-areas identified to be inadequately performing using the LQAS method with less than 30 respondents, and the HDSS was not statistically significant. The consistency between the LQAS method and the HDSS in identifying work-areas was greater for adequately-performing areas than inadequately-performing areas. It was also observed that the field managers could be trained to apply the LQAS method in monitoring their performance in reaching the target population. PMID:17615902

  14. Performance of the lot quality assurance sampling method compared to surveillance for identifying inadequately-performing areas in Matlab, Bangladesh.

    PubMed

    Bhuiya, Abbas; Hanifi, S M A; Roy, Nikhil; Streatfield, P Kim

    2007-03-01

    This paper compared the performance of the lot quality assurance sampling (LQAS) method in identifying inadequately-performing health work-areas with that of using health and demographic surveillance system (HDSS) data and examined the feasibility of applying the method by field-level programme supervisors. The study was carried out in Matlab, the field site of ICDDR,B, where a HDSS has been in place for over 30 years. The LQAS method was applied in 57 work-areas of community health workers in ICDDR,B-served areas in Matlab during July-September 2002. The performance of the LQAS method in identifying work-areas with adequate and inadequate coverage of various health services was compared with those of the HDSS. The health service-coverage indicators included coverage of DPT, measles, BCG vaccination, and contraceptive use. It was observed that the difference in the proportion of work-areas identified to be inadequately performing using the LQAS method with less than 30 respondents, and the HDSS was not statistically significant. The consistency between the LQAS method and the HDSS in identifying work-areas was greater for adequately-performing areas than inadequately-performing areas. It was also observed that the field managers could be trained to apply the LQAS method in monitoring their performance in reaching the target population.

  15. Addressing the workplace needs of Western Australian midwives: a Delphi study.

    PubMed

    Hauck, Yvonne L; Bayes, Sara J; Robertson, Jeanette M

    2012-05-01

    To determine the workplace needs of Western Australian midwives working in public metropolitan secondary hospitals. Using a three-round Delphi approach, Round 1 incorporated focus groups and a questionnaire. Fifteen focus groups were conducted with midwives also having the option of contributing through an open-ended questionnaire. During Round 2, 38 items reflecting seven themes were prioritised with a final ranking performed in Round 3. In total, 114 midwives participated in Round 1, 72 in Round 2 and 89 in Round 3. During Round 1, workplace needs identified as being met included: working across all areas of midwifery; ability to work in areas of interest; opportunity to work with low to moderate risk women; supportive colleagues; accessible parking; hospital close to home and friendly work atmosphere. Round 2 items revealed the five top unmet needs as: adequate midwifery staff coverage; access to maintained equipment; competitive pay scales; patient safety issues and opportunities to implement midwifery models. The top ranked needs from Round 3 included: recognising the unpredictable nature of midwifery services; provision of competent medical coverage, and adequate midwifery staff coverage. Demand for maternity services is unpredictable; however, in order to maintain a sustainable maternity workforce, WA midwives' prioritised needs would suggest health management focus upon expanding the availability of midwifery models of care, fostering flexible working conditions and ensuring collaboration between maternity health professionals occurs within clinically safe staffing levels.

  16. [Coverage by the Family Health Strategy and diagnosis of syphilis in pregnancy and congenital syphilis].

    PubMed

    Saraceni, Valéria; Miranda, Angélica Espinosa

    2012-03-01

    This paper aimed to correlate syphilis in pregnancy and congenital syphilis with coverage of the Family Health Strategy (FHS), based on available data in the national health information systems. The syphilis notification estimates were calculated according to the Sentinel Childbirth Study for 2004 under the Ministry of Health and the data were obtained from the websites of the Health Surveillance Secretariat and Healthcare Secretariat, for the year 2008. The ratios between observed and estimated gestational syphilis and congenital syphilis were not statistically correlated with population coverage by the FHS (r = -0.28 and r = -0.40, respectively). The FHS is a privileged area for prenatal care and logically a source of compulsory notification of syphilis in pregnancy. By combining diagnosis with adequate treatment of syphilis in pregnant women and their partners, the FHS becomes a prime instrument for eliminating congenital syphilis in Brazil. Expanding the FHS coverage and quality of care are essential for achieving this goal.

  17. Influenza vaccination coverage among US children from 2004/2005 to 2015/2016.

    PubMed

    Tian, Changwei; Wang, Hua; Wang, Wenming; Luo, Xiaoming

    2018-05-15

    Quantify the influenza vaccine coverage is essential to identify emerging concerns and to immunization programs for targeting interventions. Data from National Health Interview Survey were used to estimate receipt of at least one dose of influenza vaccination among children 6 months to 17 years of age. Influenza vaccination coverage increased from 16.70% during 2004/2005 to 49.43% during 2015/2016 (3.18% per year, P < 0.001); however, the coverage increased slightly after 2010/2011. Children at high risk of influenza complications had higher influenza vaccination coverage than non at-risk children. Boys and girls had similar coverage each year. While the coverage increased from 2004/2005 to 2015/2016 for all age groups, the coverage decreased with age each year (-0.64 to -1.58% per age group). There was a higher and rapid increase of coverage in Northeast than Midwest, South and West. American Indian or Alaskan Native and Asian showed higher coverage than other race groups (White, Black/African American, Multiple race). Multivariable analysis showed that high-risk status and region had the greatest associations with levels of vaccine coverage. Although the influenza vaccination coverage among children had increased remarkably since 2004/2005, establishing more effective immunization programs are warranted to achieve the Healthy People 2020 target.

  18. Assessment of targeting accuracy of a low-energy stereotactic radiosurgery treatment for age-related macular degeneration

    NASA Astrophysics Data System (ADS)

    Taddei, Phillip J.; Chell, Erik; Hansen, Steven; Gertner, Michael; Newhauser, Wayne D.

    2010-12-01

    Age-related macular degeneration (AMD), a leading cause of blindness in the United States, is a neovascular disease that may be controlled with radiation therapy. Early patient outcomes of external beam radiotherapy, however, have been mixed. Recently, a novel multimodality treatment was developed, comprising external beam radiotherapy and concomitant treatment with a vascular endothelial growth factor inhibitor. The radiotherapy arm is performed by stereotactic radiosurgery, delivering a 16 Gy dose in the macula (clinical target volume, CTV) using three external low-energy x-ray fields while adequately sparing normal tissues. The purpose of our study was to test the sensitivity of the delivery of the prescribed dose in the CTV using this technique and of the adequate sparing of normal tissues to all plausible variations in the position and gaze angle of the eye. Using Monte Carlo simulations of a 16 Gy treatment, we varied the gaze angle by ±5° in the polar and azimuthal directions, the linear displacement of the eye ±1 mm in all orthogonal directions, and observed the union of the three fields on the posterior wall of spheres concentric with the eye that had diameters between 20 and 28 mm. In all cases, the dose in the CTV fluctuated <6%, the maximum dose in the sclera was <20 Gy, the dose in the optic disc, optic nerve, lens and cornea were <0.7 Gy and the three-field junction was adequately preserved. The results of this study provide strong evidence that for plausible variations in the position of the eye during treatment, either by the setup error or intrafraction motion, the prescribed dose will be delivered to the CTV and the dose in structures at risk will be kept far below tolerance doses.

  19. Evaluating Childhood Vaccination Coverage of NIP Vaccines: Coverage Survey versus Zhejiang Provincial Immunization Information System.

    PubMed

    Hu, Yu; Chen, Yaping

    2017-07-11

    Vaccination coverage in Zhejiang province, east China, is evaluated through repeated coverage surveys. The Zhejiang provincial immunization information system (ZJIIS) was established in 2004 with links to all immunization clinics. ZJIIS has become an alternative to quickly assess the vaccination coverage. To assess the current completeness and accuracy on the vaccination coverage derived from ZJIIS, we compared the estimates from ZJIIS with the estimates from the most recent provincial coverage survey in 2014, which combined interview data with verified data from ZJIIS. Of the enrolled 2772 children in the 2014 provincial survey, the proportions of children with vaccination cards and registered in ZJIIS were 94.0% and 87.4%, respectively. Coverage estimates from ZJIIS were systematically higher than the corresponding estimates obtained through the survey, with a mean difference of 4.5%. Of the vaccination doses registered in ZJIIS, 16.7% differed from the date recorded in the corresponding vaccination cards. Under-registration in ZJIIS significantly influenced the coverage estimates derived from ZJIIS. Therefore, periodic coverage surveys currently provide more complete and reliable results than the estimates based on ZJIIS alone. However, further improvement of completeness and accuracy of ZJIIS will likely allow more reliable and timely estimates in future.

  20. Developing and implementing a high precision setup system

    NASA Astrophysics Data System (ADS)

    Peng, Lee-Cheng

    The demand for high-precision radiotherapy (HPRT) was first implemented in stereotactic radiosurgery using a rigid, invasive stereotactic head frame. Fractionated stereotactic radiotherapy (SRT) with a frameless device was developed along a growing interest in sophisticated treatment with a tight margin and high-dose gradient. This dissertation establishes the complete management for HPRT in the process of frameless SRT, including image-guided localization, immobilization, and dose evaluation. The most ideal and precise positioning system can allow for ease of relocation, real-time patient movement assessment, high accuracy, and no additional dose in daily use. A new image-guided stereotactic positioning system (IGSPS), the Align RT3C 3D surface camera system (ART, VisionRT), which combines 3D surface images and uses a real-time tracking technique, was developed to ensure accurate positioning at the first place. The uncertainties of current optical tracking system, which causes patient discomfort due to additional bite plates using the dental impression technique and external markers, are found. The accuracy and feasibility of ART is validated by comparisons with the optical tracking and cone-beam computed tomography (CBCT) systems. Additionally, an effective daily quality assurance (QA) program for the linear accelerator and multiple IGSPSs is the most important factor to ensure system performance in daily use. Currently, systematic errors from the phantom variety and long measurement time caused by switching phantoms were discovered. We investigated the use of a commercially available daily QA device to improve the efficiency and thoroughness. Reasonable action level has been established by considering dosimetric relevance and clinic flow. As for intricate treatments, the effect of dose deviation caused by setup errors remains uncertain on tumor coverage and toxicity on OARs. The lack of adequate dosimetric simulations based on the true treatment coordinates from the treatment planning system (TPS) has limited adaptive treatments. A reliable and accurate dosimetric simulation using TPS and in-house software in uncorrected errors has been developed. In SRT, the calculated dose deviation is compared to the original treatment dose with the dose-volume histogram to investigate the dose effect of rotational errors. In summary, this work performed a quality assessment to investigate the overall accuracy of current setup systems. To reach the ideal HPRT, the reliable dosimetric simulation, an effective daily QA program and effective, precise setup systems were developed and validated.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morrison, Hali, E-mail: hamorris@ualberta.ca; Meno

    Purpose: To estimate the total dosimetric uncertainty at the tumor apex for ocular brachytherapy treatments delivered using 16 mm Collaborative Ocular Melanoma Study (COMS) and Super9 plaques loaded with {sup 125}I seeds in order to determine the size of the apex margin that would be required to ensure adequate dosimetric coverage of the tumor. Methods: The total dosimetric uncertainty was assessed for three reference tumor heights: 3, 5, and 10 mm, using the Guide to the expression of Uncertainty in Measurement/National Institute of Standards and Technology approach. Uncertainties pertaining to seed construction, source strength, plaque assembly, treatment planning calculations, tumormore » height measurement, plaque placement, and plaque tilt for a simple dome-shaped tumor were investigated and quantified to estimate the total dosimetric uncertainty at the tumor apex. Uncertainties in seed construction were determined using EBT3 Gafchromic film measurements around single seeds, plaque assembly uncertainties were determined using high resolution microCT scanning of loaded plaques to measure seed positions in the plaques, and all other uncertainties were determined from the previously published studies and recommended values. All dose calculations were performed using PLAQUESIMULATOR v5.7.6 ophthalmic treatment planning system with the inclusion of plaque heterogeneity corrections. Results: The total dosimetric uncertainties at 3, 5, and 10 mm tumor heights for the 16 mm COMS plaque were 17.3%, 16.1%, and 14.2%, respectively, and for the Super9 plaque were 18.2%, 14.4%, and 13.1%, respectively (all values with coverage factor k = 2). The apex margins at 3, 5, and 10 mm tumor heights required to adequately account for these uncertainties were 1.3, 1.3, and 1.4 mm, respectively, for the 16 mm COMS plaque, and 1.8, 1.4, and 1.2 mm, respectively, for the Super9 plaque. These uncertainties and associated margins are dependent on the dose gradient at the given prescription depth, thus resulting in the changing uncertainties and margins with depth. Conclusions: The margins determined in this work can be used as a guide for determining an appropriate apex margin for a given treatment, which can be chosen based on the tumor height. The required margin may need to be increased for more complex scenarios (mushroom shaped tumors, tumors close to the optic nerve, oblique muscle related tilt, etc.) than the simple dome-shaped tumor examined and should be chosen on a case-by-case basis. The sources of uncertainty contributing most significantly to the total dosimetric uncertainty are seed placement within the plaques, treatment planning calculations, tumor height measurement, and plaque tilt. This work presents an uncertainty-based, rational approach to estimating an appropriate apex margin.« less

  2. Patient-specific dose estimation for pediatric chest CT

    PubMed Central

    Li, Xiang; Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Frush, Donald P.

    2008-01-01

    Current methods for organ and effective dose estimations in pediatric CT are largely patient generic. Physical phantoms and computer models have only been developed for standard/limited patient sizes at discrete ages (e.g., 0, 1, 5, 10, 15years old) and do not reflect the variability of patient anatomy and body habitus within the same size/age group. In this investigation, full-body computer models of seven pediatric patients in the same size/protocol group (weight: 11.9–18.2kg) were created based on the patients’ actual multi-detector array CT (MDCT) data. Organs and structures in the scan coverage were individually segmented. Other organs and structures were created by morphing existing adult models (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. Organ and effective dose of these patients from a chest MDCT scan protocol (64 slice LightSpeed VCT scanner, 120kVp, 70 or 75mA, 0.4s gantry rotation period, pitch of 1.375, 20mm beam collimation, and small body scan field-of-view) was calculated using a Monte Carlo program previously developed and validated to simulate radiation transport in the same CT system. The seven patients had normalized effective dose of 3.7–5.3mSv∕100mAs (coefficient of variation: 10.8%). Normalized lung dose and heart dose were 10.4–12.6mGy∕100mAs and 11.2–13.3mGy∕100mAs, respectively. Organ dose variations across the patients were generally small for large organs in the scan coverage (<7%), but large for small organs in the scan coverage (9%–18%) and for partially or indirectly exposed organs (11%–77%). Normalized effective dose correlated weakly with body weight (correlation coefficient:r=−0.80). Normalized lung dose and heart dose correlated strongly with mid-chest equivalent diameter (lung: r=−0.99, heart: r=−0.93); these strong correlation relationships can be used to estimate patient-specific organ dose for any other patient in the same size/protocol group who undergoes the chest scan. In summary, this work reported the first assessment of dose variations across pediatric CT patients in the same size/protocol group due to the variability of patient anatomy and body habitus and provided a previously unavailable method for patient-specific organ dose estimation, which will help in assessing patient risk and optimizing dose reduction strategies, including the development of scan protocols. PMID:19175138

  3. Patient-specific dose estimation for pediatric chest CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li Xiang; Samei, Ehsan; Segars, W. Paul

    2008-12-15

    Current methods for organ and effective dose estimations in pediatric CT are largely patient generic. Physical phantoms and computer models have only been developed for standard/limited patient sizes at discrete ages (e.g., 0, 1, 5, 10, 15 years old) and do not reflect the variability of patient anatomy and body habitus within the same size/age group. In this investigation, full-body computer models of seven pediatric patients in the same size/protocol group (weight: 11.9-18.2 kg) were created based on the patients' actual multi-detector array CT (MDCT) data. Organs and structures in the scan coverage were individually segmented. Other organs and structuresmore » were created by morphing existing adult models (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. Organ and effective dose of these patients from a chest MDCT scan protocol (64 slice LightSpeed VCT scanner, 120 kVp, 70 or 75 mA, 0.4 s gantry rotation period, pitch of 1.375, 20 mm beam collimation, and small body scan field-of-view) was calculated using a Monte Carlo program previously developed and validated to simulate radiation transport in the same CT system. The seven patients had normalized effective dose of 3.7-5.3 mSv/100 mAs (coefficient of variation: 10.8%). Normalized lung dose and heart dose were 10.4-12.6 mGy/100 mAs and 11.2-13.3 mGy/100 mAs, respectively. Organ dose variations across the patients were generally small for large organs in the scan coverage (<7%), but large for small organs in the scan coverage (9%-18%) and for partially or indirectly exposed organs (11%-77%). Normalized effective dose correlated weakly with body weight (correlation coefficient: r=-0.80). Normalized lung dose and heart dose correlated strongly with mid-chest equivalent diameter (lung: r=-0.99, heart: r=-0.93); these strong correlation relationships can be used to estimate patient-specific organ dose for any other patient in the same size/protocol group who undergoes the chest scan. In summary, this work reported the first assessment of dose variations across pediatric CT patients in the same size/protocol group due to the variability of patient anatomy and body habitus and provided a previously unavailable method for patient-specific organ dose estimation, which will help in assessing patient risk and optimizing dose reduction strategies, including the development of scan protocols.« less

  4. Expansion of Vaccination Services and Strengthening Vaccine-Preventable Diseases Surveillance in Haiti, 2010–2016

    PubMed Central

    Tohme, Rania A.; Francois, Jeannot; Cavallaro, Kathleen F.; Paluku, Gilson; Yalcouye, Idrissa; Jackson, Ernsley; Wright, Tracie; Adrien, Paul; Katz, Mark A.; Hyde, Terri B.; Faye, Pape; Kimanuka, Francine; Dietz, Vance; Vertefeuille, John; Lowrance, David; Dahl, Benjamin; Patel, Roopal

    2017-01-01

    Abstract. Following the 2010 earthquake, Haiti was at heightened risk for vaccine-preventable diseases (VPDs) outbreaks due to the exacerbation of long-standing gaps in the vaccination program and subsequent risk of VPD importation from other countries. Therefore, partners supported the Haitian Ministry of Health and Population to improve vaccination services and VPD surveillance. During 2010–2016, three polio, measles, and rubella vaccination campaigns were implemented, achieving a coverage > 90% among children and maintaining Haiti free of those VPDs. Furthermore, Haiti is on course to eliminate maternal and neonatal tetanus, with 70% of communes achieving tetanus vaccine two-dose coverage > 80% among women of childbearing age. In addition, the vaccine cold chain storage capacity increased by 91% at the central level and 285% at the department level, enabling the introduction of three new vaccines (pentavalent, rotavirus, and pneumococcal conjugate vaccines) that could prevent an estimated 5,227 deaths annually. Haiti moved from the fourth worst performing country in the Americas in 2012 to the sixth best performing country in 2015 for adequate investigation of suspected measles/rubella cases. Sentinel surveillance sites for rotavirus diarrhea and meningococcal meningitis were established to estimate baseline rates of those diseases prior to vaccine introduction and to evaluate the impact of vaccination in the future. In conclusion, Haiti significantly improved vaccination services and VPD surveillance. However, high dependence on external funding and competing vaccination program priorities are potential threats to sustaining the improvements achieved thus far. Political commitment and favorable economic and legal environments are needed to maintain these gains. PMID:29064356

  5. The global pertussis initiative: Meeting report from the Regional Latin America Meeting, Costa Rica, 5-6 December, 2008.

    PubMed

    Ulloa-Gutierrez, Rolando; Hozbor, Daniela; Avila-Aguero, Maria L; Caro, Jaime; Wirsing von König, Carl-Heinz; Tan, Tina; Plotkin, Stanley

    2010-11-01

    Pertussis remains endemic across the world, with an estimated 279,000 deaths in 2002, the majority in infants under 1 year of age. Worldwide epidemiologic data indicates increasing infection rates in older children and adults, which act as a source of infection to young infants. The Global Pertussis Initiative (GPI) is an expert scientific forum, which has published consensus recommendations for the monitoring, prevention, and treatment of the disease. This paper reports the proceedings of a regional meeting, held in Costa Rica in December 2008. The meeting gathered information on regional epidemiological, diagnostic capabilities and the ability to introduce GPI recommended vaccine strategies in Latin America. The capacity of Latin American countries to conduct vaccination programs is high and there is considerable government support. Whole-cell pertussis vaccines are used across Latin America, which appear to be quite effective. A 4-dose schedule is typically used (2, 4, 6, and 18 months), and a booster given at 4 to 6 years of age, with coverage often above 90%, but with regions of low coverage due to political and geographical difficulties. Adequate surveillance is lacking in many countries, giving insufficient data to guide vaccination policy. Improvements are being made, with countries such as Costa Rica, Panama, and Argentina introducing polymerase chain reaction (PCR) diagnosis. Those countries that do not currently use a preschool booster should launch one. Implementing vaccination programs in adolescents and/or adults to reduce exposure to infants would be beneficial and possible in most countries, given their current infrastructure.

  6. A Changing Landscape for Vitamin A Programs: Implications for Optimal Intervention Packages, Program Monitoring, and Safety.

    PubMed

    Klemm, Rolf D W; Palmer, Amanda C; Greig, Alison; Engle-Stone, Reina; Dalmiya, Nita

    2016-06-01

    Vitamin A deficiency (VAD) remains a widespread public health problem in the developing world, despite changes in under-5 mortality rates, morbidity patterns, and intervention options. This article considers the implications of a changing epidemiologic and programmatic landscape for vitamin A (VA) programs. We review progress to prevent VAD and its health consequences, assess gaps in VA status and intervention coverage data, and assess data needed to guide decisions regarding the optimal mix, targeting, and dose of VA interventions to maximize benefit and minimize risk. Vitamin A supplementation programs have contributed to the reduction in under-5 mortality rates, but alone, do not address the underlying problem of inadequate dietary VA intakes and VAD among preschool-aged children in the developing world. A combination of VA interventions (eg, supplementation, fortified foods, multiple micronutrient powders, and lipid-based nutrient supplements) will be required to achieve VA adequacy in most settings. Current efforts to measure the coverage of multiple VA interventions, as well as whether and how much VA children are receiving, are few and fragmented. Where intervention overlap exists, further effort is needed to monitor VA intakes, ensuring that targeted groups are consuming adequate amounts but not exceeding the tolerable upper intake level. Vitamin A status data will also be critical for navigating the changing landscape of VA programs. Data from these monitoring efforts will help to guide decisions on the optimal mix, targeting, and exposure to VA interventions to maximize public health benefit while minimizing any potential risk. © The Author(s) 2016.

  7. Breast Radiotherapy with Mixed Energy Photons; a Model for Optimal Beam Weighting.

    PubMed

    Birgani, Mohammadjavad Tahmasebi; Fatahiasl, Jafar; Hosseini, Seyed Mohammad; Bagheri, Ali; Behrooz, Mohammad Ali; Zabiehzadeh, Mansour; Meskani, Reza; Gomari, Maryam Talaei

    2015-01-01

    Utilization of high energy photons (>10 MV) with an optimal weight using a mixed energy technique is a practical way to generate a homogenous dose distribution while maintaining adequate target coverage in intact breast radiotherapy. This study represents a model for estimation of this optimal weight for day to day clinical usage. For this purpose, treatment planning computed tomography scans of thirty-three consecutive early stage breast cancer patients following breast conservation surgery were analyzed. After delineation of the breast clinical target volume (CTV) and placing opposed wedge paired isocenteric tangential portals, dosimeteric calculations were conducted and dose volume histograms (DVHs) were generated, first with pure 6 MV photons and then these calculations were repeated ten times with incorporating 18 MV photons (ten percent increase in weight per step) in each individual patient. For each calculation two indexes including maximum dose in the breast CTV (Dmax) and the volume of CTV which covered with 95% Isodose line (VCTV, 95%IDL) were measured according to the DVH data and then normalized values were plotted in a graph. The optimal weight of 18 MV photons was defined as the intersection point of Dmax and VCTV, 95%IDL graphs. For creating a model to predict this optimal weight multiple linear regression analysis was used based on some of the breast and tangential field parameters. The best fitting model for prediction of 18 MV photons optimal weight in breast radiotherapy using mixed energy technique, incorporated chest wall separation plus central lung distance (Adjusted R2=0.776). In conclusion, this study represents a model for the estimation of optimal beam weighting in breast radiotherapy using mixed photon energy technique for routine day to day clinical usage.

  8. Seasonal influenza vaccine coverage among high-risk populations in Thailand, 2010-2012.

    PubMed

    Owusu, Jocelynn T; Prapasiri, Prabda; Ditsungnoen, Darunee; Leetongin, Grit; Yoocharoen, Pornsak; Rattanayot, Jarowee; Olsen, Sonja J; Muangchana, Charung

    2015-01-29

    The Advisory Committee on Immunization Practice of Thailand prioritizes seasonal influenza vaccinations for populations who are at highest risk for serious complications (pregnant women, children 6 months-2 years, persons ≥65 years, persons with chronic diseases, obese persons), and healthcare personnel and poultry cullers. The Thailand government purchases seasonal influenza vaccine for these groups. We assessed vaccination coverage among high-risk groups in Thailand from 2010 to 2012. National records on persons who received publicly purchased vaccines from 2010 to 2012 were analyzed by high-risk category. Denominator data from multiple sources were compared to calculate coverage. Vaccine coverage was defined as the proportion of individuals in each category who received the vaccine. Vaccine wastage was defined as the proportion of publicly purchased vaccines that were not used. From 2010 to 2012, 8.18 million influenza vaccines were publicly purchased (range, 2.37-3.29 million doses/year), and vaccine purchases increased 39% over these years. Vaccine wastage was 9.5%. Approximately 5.7 million (77%) vaccine doses were administered to persons ≥65 years and persons with chronic diseases, 1.4 million (19%) to healthcare personnel/poultry cullers, 82,570 (1.1%) to children 6 months-2 years, 78,885 (1.1%) to obese persons, 26,481 (0.4%) to mentally disabled persons, and 17,787 (0.2%) to pregnant women. Between 2010 and 2012, coverage increased among persons with chronic diseases (8.6% versus 14%; p<0.01) and persons ≥65 years (12%, versus 20%; p<0.01); however, coverage decreased for mentally disabled persons (6.1% versus 4.9%; p<0.01), children 6 months-2 years (2.3% versus 0.9%; p<0.01), pregnant women (1.1% versus 0.9%; p<0.01), and obese persons (0.2% versus 0.1%; p<0.01). From 2010 to 2012, the availability of publicly purchased vaccines increased. While coverage remained low for all target groups, coverage was highest among persons ≥65 years and persons with chronic diseases. Annual coverage assessments are necessary to promote higher coverage among high-risk groups in Thailand. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. Seasonal influenza vaccine coverage among high-risk populations in Thailand, 2010–2012

    PubMed Central

    Owusu, Jocelynn T.; Prapasiri, Prabda; Ditsungnoen, Darunee; Leetongin, Grit; Yoocharoen, Pornsak; Rattanayot, Jarowee; Olsen, Sonja J.; Muangchana, Charung

    2015-01-01

    Background The Advisory Committee on Immunization Practice of Thailand prioritizes seasonal influenza vaccinations for populations who are at highest risk for serious complications (pregnant women, children 6 months–2 years, persons ≥65 years, persons with chronic diseases, obese persons), and health-care personnel and poultry cullers. The Thailand government purchases seasonal influenza vaccine for these groups. We assessed vaccination coverage among high-risk groups in Thailand from 2010 to 2012. Methods National records on persons who received publicly purchased vaccines from 2010 to 2012 were analyzed by high-risk category. Denominator data from multiple sources were compared to calculate coverage. Vaccine coverage was defined as the proportion of individuals in each category who received the vaccine. Vaccine wastage was defined as the proportion of publicly purchased vaccines that were not used. Results From 2010 to 2012, 8.18 million influenza vaccines were publicly purchased (range, 2.37–3.29 million doses/year), and vaccine purchases increased 39% over these years. Vaccine wastage was 9.5%. Approximately 5.7 million (77%) vaccine doses were administered to persons ≥65 years and persons with chronic diseases, 1.4 million (19%) to healthcare personnel/poultry cullers, 82,570 (1.1%) to children 6 months–2 years, 78,885 (1.1%) to obese persons, 26,481 (0.4%) to mentally disabled persons, and 17,787 (0.2%) to pregnant women. Between 2010 and 2012, coverage increased among persons with chronic diseases (8.6% versus 14%; p < 0.01) and persons ≥65 years (12%, versus 20%; p < 0.01); however, coverage decreased for mentally disabled persons (6.1% versus 4.9%; p < 0.01), children 6 months–2 years (2.3% versus 0.9%; p < 0.01), pregnant women (1.1% versus 0.9%; p < 0.01), and obese persons (0.2% versus 0.1%; p < 0.01). Conclusions From 2010 to 2012, the availability of publicly purchased vaccines increased. While coverage remained low for all target groups, coverage was highest among persons ≥65 years and persons with chronic diseases. Annual coverage assessments are necessary to promote higher coverage among high-risk groups in Thailand. PMID:25454853

  10. Hepatitis B Virus Infection in Indonesia 15 Years After Adoption of a Universal Infant Vaccination Program: Possible Impacts of Low Birth Dose Coverage and a Vaccine-Escape Mutant.

    PubMed

    Purwono, Priyo Budi; Juniastuti; Amin, Mochamad; Bramanthi, Rendra; Nursidah; Resi, Erika Maria; Wahyuni, Rury Mega; Yano, Yoshihiko; Soetjipto; Hotta, Hak; Hayashi, Yoshitake; Utsumi, Takako; Lusida, Maria Inge

    2016-09-07

    A universal hepatitis B vaccination program for infants was adopted in Indonesia in 1997. Before its implementation, the prevalence of hepatitis B surface antigen (HBsAg)-positive individuals in the general population was approximately 5-10%. The study aimed to investigate the hepatitis B virus (HBV) serological status and molecular profile among children, 15 years after adoption of a universal infant vaccination program in Indonesia. According to the Local Health Office data in five areas, the percentages of children receiving three doses of hepatitis B vaccine are high (73.9-94.1%), whereas the birth dose coverage is less than 50%. Among 967 children in those areas, the seropositive rate of HBsAg in preschool- and school-aged children ranged from 2.1% to 4.2% and 0% to 5.9%, respectively. Of the 61 HBV DNA-positive samples, the predominant genotype/subtype was B/adw2 Subtype adw3 was identified in genotype C for the first time in this population. Six samples (11.5%) had an amino acid substitution within the a determinant of the S gene region, and one sample had T140I that was suggested as a vaccine-escape mutant type. The low birth dose coverage and the presence of a vaccine-escape mutant might contribute to the endemicity of HBV infection among children in Indonesia. © The American Society of Tropical Medicine and Hygiene.

  11. Hepatitis B Virus Infection in Indonesia 15 Years after Adoption of a Universal Infant Vaccination Program: Possible Impacts of Low Birth Dose Coverage and a Vaccine-Escape Mutant

    PubMed Central

    Purwono, Priyo Budi; Juniastuti; Amin, Mochamad; Bramanthi, Rendra; Nursidah; Resi, Erika Maria; Wahyuni, Rury Mega; Yano, Yoshihiko; Soetjipto; Hotta, Hak; Hayashi, Yoshitake; Utsumi, Takako; Lusida, Maria Inge

    2016-01-01

    A universal hepatitis B vaccination program for infants was adopted in Indonesia in 1997. Before its implementation, the prevalence of hepatitis B surface antigen (HBsAg)–positive individuals in the general population was approximately 5–10%. The study aimed to investigate the hepatitis B virus (HBV) serological status and molecular profile among children, 15 years after adoption of a universal infant vaccination program in Indonesia. According to the Local Health Office data in five areas, the percentages of children receiving three doses of hepatitis B vaccine are high (73.9–94.1%), whereas the birth dose coverage is less than 50%. Among 967 children in those areas, the seropositive rate of HBsAg in preschool- and school-aged children ranged from 2.1% to 4.2% and 0% to 5.9%, respectively. Of the 61 HBV DNA–positive samples, the predominant genotype/subtype was B/adw2. Subtype adw3 was identified in genotype C for the first time in this population. Six samples (11.5%) had an amino acid substitution within the a determinant of the S gene region, and one sample had T140I that was suggested as a vaccine-escape mutant type. The low birth dose coverage and the presence of a vaccine-escape mutant might contribute to the endemicity of HBV infection among children in Indonesia. PMID:27402524

  12. SU-F-T-389: Validation in 4D Dosimetry Using Dynamic Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, C; Lin, C; Tu, P

    2016-06-15

    Purpose: Tumor motion due to respiration causes the uncertainties during the radiotherapy. This study aims to find the differences between planning dose by treatment planning and the received dose using dynamic phantom. Methods: Respiratory motion was simulated by the DYNAMIC THORAX PHANTOM (Model 008A). 4D-CT scans and maximum intensity projection (MIP) images for GTV were acquired for analysis. The amplitude of craniocaudal tumor motion including 2mm, 5mm, 10mm and 20mm with 3cm2 tumor size were performed in this study. The respiratory cycles of 4-seconds and 6-seconds were included as the different breathing modes. IMRT, VAMT, and Tomotherapy were utilized formore » treatment planning. Ion chamber and EBT3 were used to measure the point dose and planar dose. Dose distributions with different amplitudes, respiratory cycles, and planning techniques were all measured and compared to calculations. Results: The variations between the does measurements and calculation dose by treatment planning system were found in both point dose and dose distribution. The 0.83% and 5.46 % differences in dose average were shown on phantom with motions using 2mm amplitude in 4 second respiratory cycle, and 20mm amplitude in 4 second respiratory cycle, respectively. The most point dose overestimation as compared of the calculations was shown the plan generated by Tomotherapy. The underestimations of planar dose as compared of calculations was found in the 100% coverage doses for GTV. Conclusion: The loss of complete (100%) GTV coverage was the predominant effect of respiratory motion observed in this study. Motion amplitude and treatment planning system were the major factors leading the dose measurement variation as compared of planning calculations.« less

  13. Successful respiratory immunization with dry powder live-attenuated measles virus vaccine in rhesus macaques

    PubMed Central

    Lin, Wen-Hsuan; Griffin, Diane E.; Rota, Paul A.; Papania, Mark; Cape, Stephen P.; Bennett, David; Quinn, Brian; Sievers, Robert E.; Shermer, Charles; Powell, Kenneth; Adams, Robert J.; Godin, Steven; Winston, Scott

    2011-01-01

    Measles remains an important cause of childhood mortality worldwide. Sustained high vaccination coverage is the key to preventing measles deaths. Because measles vaccine is delivered by injection, hurdles to high coverage include the need for trained medical personnel and a cold chain, waste of vaccine in multidose vials and risks associated with needle use and disposal. Respiratory vaccine delivery could lower these barriers and facilitate sustained high coverage. We developed a novel single unit dose, dry powder live-attenuated measles vaccine (MVDP) for respiratory delivery without reconstitution. We tested the immunogenicity and protective efficacy in rhesus macaques of one dose of MVDP delivered either with a mask or directly intranasal with two dry powder inhalers, PuffHaler and BD Solovent. MVDP induced robust measles virus (MeV)-specific humoral and T-cell responses, without adverse effects, which completely protected the macaques from infection with wild-type MeV more than one year later. Respiratory delivery of MVDP was safe and effective and could aid in measles control. PMID:21282608

  14. Successful respiratory immunization with dry powder live-attenuated measles virus vaccine in rhesus macaques.

    PubMed

    Lin, Wen-Hsuan; Griffin, Diane E; Rota, Paul A; Papania, Mark; Cape, Stephen P; Bennett, David; Quinn, Brian; Sievers, Robert E; Shermer, Charles; Powell, Kenneth; Adams, Robert J; Godin, Steven; Winston, Scott

    2011-02-15

    Measles remains an important cause of childhood mortality worldwide. Sustained high vaccination coverage is the key to preventing measles deaths. Because measles vaccine is delivered by injection, hurdles to high coverage include the need for trained medical personnel and a cold chain, waste of vaccine in multidose vials and risks associated with needle use and disposal. Respiratory vaccine delivery could lower these barriers and facilitate sustained high coverage. We developed a novel single unit dose, dry powder live-attenuated measles vaccine (MVDP) for respiratory delivery without reconstitution. We tested the immunogenicity and protective efficacy in rhesus macaques of one dose of MVDP delivered either with a mask or directly intranasal with two dry powder inhalers, PuffHaler and BD Solovent. MVDP induced robust measles virus (MeV)-specific humoral and T-cell responses, without adverse effects, which completely protected the macaques from infection with wild-type MeV more than one year later. Respiratory delivery of MVDP was safe and effective and could aid in measles control.

  15. Improved normal tissue sparing in head and neck radiotherapy using biological cost function based-IMRT.

    PubMed

    Anderson, N; Lawford, C; Khoo, V; Rolfo, M; Joon, D L; Wada, M

    2011-12-01

    Intensity-modulated radiotherapy (IMRT) has reduced the impact of acute and late toxicities associated with head and neck radiotherapy. Treatment planning system (TPS) advances in biological cost function based optimization (BBO) and improved segmentation techniques have increased organ at risk (OAR) sparing compared to conventional dose-based optimization (DBO). A planning study was undertaken to compare OAR avoidance in DBO and BBO treatment planning. Simultaneous integrated boost treatment plans were produced for 10 head and neck patients using both planning systems. Plans were compared for tar get coverage and OAR avoidance. Comparisons were made using the BBO TPS Monte Carlo dose engine to eliminate differences due to inherent algorithms. Target coverage (V95%) was maintained for both solutions. BBO produced lower OAR doses, with statistically significant improvement to left (12.3%, p = 0.005) and right parotid mean dose (16.9%, p = 0.004), larynx V50_Gy (71.0%, p = 0.005), spinal cord (21.9%, p < 0.001) and brain stem dose maximums (31.5%, p = 0.002). This study observed improved OAR avoidance with BBO planning. Further investigations will be undertaken to review any clinical benefit of this improved planned dosimetry.

  16. Improved Normal Tissue Sparing in Head and Neck Radiotherapy Using Biological Cost Function Based-IMRT

    PubMed Central

    Anderson, N.; Lawford, C.; Khoo, V.; Rolfo, M.; Joon, D. Lim; Wada, M.

    2011-01-01

    Intensity-modulated radiotherapy (IMRT) has reduced the impact of acute and late toxicities associated with head and neck radiotherapy. Treatment planning system (TPS) advances in biological cost function based optimization (BBO) and improved segmentation techniques have increased organ at risk (OAR) sparing compared to conventional dose-based optimization (DBO). A planning study was undertaken to compare OAR avoidance in DBO and BBO treatment planning. Simultaneous integrated boost treatment plans were produced for 10 head and neck patients using both planning systems. Plans were compared for tar get coverage and OAR avoidance. Comparisons were made using the BBO TPS Monte Carlo dose engine to eliminate differences due to inherent algorithms. Target coverage (V95%) was maintained for both solutions. BBO produced lower OAR doses, with statistically significant improvement to left (12.3%, p = 0.005) and right parotid mean dose (16.9%, p = 0.004), larynx V50 Gy (71.0%, p = 0.005), spinal cord (21.9%, p < 0.001) and brain stem dose maximums (31.5%, p = 0.002). This study observed improved OAR avoidance with BBO planning. Further investigations will be undertaken to review any clinical benefit of this improved planned dosimetry. PMID:22066597

  17. [Radiotherapy volume delineation based on (18F)-fluorodeoxyglucose positron emission tomography for locally advanced or inoperable oesophageal cancer].

    PubMed

    Encaoua, J; Abgral, R; Leleu, C; El Kabbaj, O; Caradec, P; Bourhis, D; Pradier, O; Schick, U

    2017-06-01

    To study the impact on radiotherapy planning of an automatically segmented target volume delineation based on ( 18 F)-fluorodeoxy-D-glucose (FDG)-hybrid positron emission tomography-computed tomography (PET-CT) compared to a manually delineation based on computed tomography (CT) in oesophageal carcinoma patients. Fifty-eight patients diagnosed with oesophageal cancer between September 2009 and November 2014 were included. The majority had squamous cell carcinoma (84.5 %), and advanced stage (37.9 % were stade IIIA) and 44.8 % had middle oesophageal lesion. Gross tumour volumes were retrospectively defined based either manually on CT or automatically on coregistered PET/CT images using three different threshold methods: standard-uptake value (SUV) of 2.5, 40 % of maximum intensity and signal-to-background ratio. Target volumes were compared in length, volume and using the index of conformality. Radiotherapy plans to the dose of 50Gy and 66Gy using intensity-modulated radiotherapy were generated and compared for both data sets. Planification target volume coverage and doses delivered to organs at risk (heart, lung and spinal cord) were compared. The gross tumour volume based manually on CT was significantly longer than that automatically based on signal-to-background ratio (6.4cm versus 5.3cm; P<0.008). Doses to the lungs (V20, D mean ), heart (V40), and spinal cord (D max ) were significantly lower on plans using the PTV SBR . The PTV SBR coverage was statistically better than the PTV CT coverage on both plans. (50Gy: P<0.0004 and 66Gy: P<0.0006). The automatic PET segmentation algorithm based on the signal-to-background ratio method for the delineation of oesophageal tumours is interesting, and results in better target volume coverage and decreased dose to organs at risk. This may allow dose escalation up to 66Gy to the gross tumour volume. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  18. Cost-effectiveness of malaria preventive treatment for HIV-infected pregnant women in sub-Saharan Africa.

    PubMed

    Choi, Sung Eun; Brandeau, Margaret L; Bendavid, Eran

    2017-10-06

    Malaria is a leading cause of morbidity and mortality among HIV-infected pregnant women in sub-Saharan Africa: at least 1 million pregnancies among HIV-infected women are complicated by co-infection with malaria annually, leading to increased risk of premature delivery, severe anaemia, delivery of low birth weight infants, and maternal death. Current guidelines recommend either daily cotrimoxazole (CTX) or intermittent preventive treatment with sulfadoxine-pyrimethamine (IPTp-SP) for HIV-infected pregnant women to prevent malaria and its complications. The cost-effectiveness of CTX compared to IPTp-SP among HIV-infected pregnant women was assessed. A microsimulation model of malaria and HIV among pregnant women in five malaria-endemic countries in sub-Saharan Africa was constructed. Four strategies were compared: (1) 2-dose IPTp-SP at current IPTp-SP coverage of the country ("2-IPT Low"); (2) 3-dose IPTp-SP at current coverage ("3-IPT Low"); (3) 3-dose IPTp-SP at the same coverage as antiretroviral therapy (ART) in the country ("3-IPT High"); and (4) daily CTX at ART coverage. Outcomes measured include maternal malaria, anaemia, low birth weight (LBW), and disability-adjusted life years (DALYs). Sensitivity analyses assessed the effect of adherence to CTX. Compared with the 2-IPT Low Strategy, women receiving CTX had 22.5% fewer LBW infants (95% CI 22.3-22.7), 13.5% fewer anaemia cases (95% CI 13.4-13.5), and 13.6% fewer maternal malaria cases (95% CI 13.6-13.7). In all simulated countries, CTX was the preferred strategy, with incremental cost-effectiveness ratios ranging from cost-saving to $3.9 per DALY averted from a societal perspective. CTX was less effective than the 3-IPT High Strategy when more than 18% of women stopped taking CTX during the pregnancy. In malarious regions of sub-Saharan Africa, daily CTX for HIV-infected pregnant women regardless of CD4 cell count is cost-effective compared with 3-dose IPTp-SP as long as more than 82% of women adhere to daily dosing.

  19. Predicting Optimal Dihydroartemisinin-Piperaquine Regimens to Prevent Malaria During Pregnancy for Human Immunodeficiency Virus-Infected Women Receiving Efavirenz.

    PubMed

    Wallender, Erika; Vucicevic, Katarina; Jagannathan, Prasanna; Huang, Liusheng; Natureeba, Paul; Kakuru, Abel; Muhindo, Mary; Nakalembe, Mirium; Havlir, Diane; Kamya, Moses; Aweeka, Francesca; Dorsey, Grant; Rosenthal, Philip J; Savic, Radojka M

    2018-03-05

    A monthly treatment course of dihydroartemisinin-piperaquine (DHA-PQ) effectively prevents malaria during pregnancy. However, a drug-drug interaction pharmacokinetic (PK) study found that pregnant human immunodeficiency virus (HIV)-infected women receiving efavirenz-based antiretroviral therapy (ART) had markedly reduced piperaquine (PQ) exposure. This suggests the need for alternative DHA-PQ chemoprevention regimens in this population. Eighty-three HIV-infected pregnant women who received monthly DHA-PQ and efavirenz contributed longitudinal PK and corrected QT interval (QTc) (n = 25) data. Population PK and PK-QTc models for PQ were developed to consider the benefits (protective PQ coverage) and risks (QTc prolongation) of alternative DHA-PQ chemoprevention regimens. Protective PQ coverage was defined as maintaining a concentration >10 ng/mL for >95% of the chemoprevention period. PQ clearance was 4540 L/day. With monthly DHA-PQ (2880 mg PQ), <1% of women achieved defined protective PQ coverage. Weekly (960 mg PQ) or low-dose daily (320 or 160 mg PQ) regimens achieved protective PQ coverage for 34% and >96% of women, respectively. All regimens were safe, with ≤2% of women predicted to have ≥30 msec QTc increase. For HIV-infected pregnant women receiving efavirenz, low daily DHA-PQ dosing was predicted to improve protection against parasitemia and reduce risk of toxicity compared to monthly dosing. NCT02282293. © The Author(s) 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  20. Evaluation of Larynx-Sparing Techniques With IMRT When Treating the Head and Neck

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Webster, Gareth J.; Rowbottom, Carl G.; Ho, Kean F.

    2008-10-01

    Purpose: Concern exists that widespread implementation of whole-field intensity-modulated radiotherapy (IMRT) for the treatment of head-and-neck cancer has resulted in increased levels of dysphagia relative to those seen with conventional planning. Other investigators have suggested an alternative junctioned-IMRT (J-IMRT) method, which matches an IMRT plan to a centrally blocked neck field to restrict the laryngeal dose and reduce dysphagia. The effect on target coverage and sparing of organs at risk, including laryngeal sparing, in the optimization was evaluated and compared with that achieved using a J-IMRT technique. Methods and Materials: A total of 13 oropharyngeal cancer whole-field IMRT plans weremore » planned with and without including laryngeal sparing in the optimization. A comparison of the target coverage and sparing of organs at risk was made using the resulting dose-volume histograms and dose distribution. The nine plans with disease located superior to the level of the larynx were replanned using a series of J-IMRT techniques to compare the two laryngeal-sparing techniques. Results: An average mean larynx dose of 29.1 Gy was achieved if disease did not extend to the level of the larynx, with 38.8 Gy for disease extending inferiorly and close to the larynx (reduced from 46.2 and 47.7 Gy, respectively, without laryngeal sparing). Additional laryngeal sparing could be achieved with J-IMRT (mean dose 24.4 Gy), although often at the expense of significantly reduced coverage of the target volume and with no improvement to other areas of the IMRT plan. Conclusion: The benefits of J-IMRT can be achieved with whole-field IMRT if laryngeal sparing is incorporated into the class solution. Inclusion of laryngeal sparing had no effect on other parameters in the plan.« less

  1. SU-E-T-333: Dosimetric Impact of Rotational Error On the Target Coverage in IMPT Lung Cancer Plans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rana, S; Zheng, Y

    2015-06-15

    Purpose: The main purpose of this study was to investigate the impact of rotational (yaw, roll, and pitch) error on the planning target volume (PTV) coverage in lung cancer plans generated by intensity modulated proton therapy (IMPT). Methods: In this retrospective study, computed tomography (CT) dataset of previously treated lung case was used. IMPT plan were generated on the original CT dataset using left-lateral (LL) and posterior-anterior (PA) beams for a total dose of 74 Gy[RBE] with 2 Gy[RBE] per fraction. In order to investigate the dosimetric impact of rotational error, 12 new CT datasets were generated by re-sampling themore » original CT dataset for rotational (roll, yaw, and pitch) angles ranged from −5° to +5°, with an increment of 2.5°. A total of 12 new IMPT plans were generated based on the re-sampled CT datasets using beam parameters identical to the ones in the original IMPT plan. All treatment plans were generated in XiO treatment planning system. The PTV coverage (i.e., dose received by 95% of the PTV volume, D95) in new IMPT plans were then compared with the PTV coverage in the original IMPT plan. Results: Rotational errors caused the reduction in the PTV coverage in all 12 new IMPT plans when compared to the original IMPT lung plan. Specifically, the PTV coverage was reduced by 4.94% to 50.51% for yaw, by 4.04% to 23.74% for roll, and by 5.21% to 46.88% for pitch errors. Conclusion: Unacceptable dosimetric results were observed in new IMPT plans as the PTV coverage was reduced by up to 26.87% and 50.51% for rotational error of 2.5° and 5°, respectively. Further investigation is underway in evaluating the PTV coverage loss in the IMPT lung cancer plans for smaller rotational angle change.« less

  2. Pertussis vaccination coverage among French parents of infants after 10years of cocoon strategy.

    PubMed

    Cohen, R; Gaudelus, J; Denis, F; Stahl, J-P; Chevaillier, O; Pujol, P; Martinot, A

    2016-06-01

    The cocoon strategy against pertussis has been recommended in France since 2004 to indirectly protect young infants who are not yet vaccinated. We aimed to measure vaccination coverage among French parents of infants. A representative sample of 300 mothers and 200 fathers of infants aged <12 months completed a self-administered online questionnaire. They all provided their own vaccination records. Overall, 87% of mothers believed vaccination against pertussis to be important; 83% reported being immunized against pertussis but their vaccination records showed that a third of them was wrong (34%). On the basis of our sample, the 2009-2014 vaccination coverage against pertussis among mothers increased from 22 to 61% (P<0.005); over the same period of time, vaccination coverage against diphtheria, tetanus, and polio remained stable (80%). Vaccination coverage against pertussis among fathers increased from 21 to 42% between 2010 and 2013 (P=0.009). In 2013, one couple out of four (26%) was adequately immunized against pertussis. The cocoon strategy was implemented 10years ago in France but vaccination coverage remains suboptimal among parents of young infants. Healthcare professionals must recommend vaccination against pertussis to young adults and check that their vaccination status is up to date. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  3. SU-E-T-62: Cardiac Toxicity in Dynamic Conformal Arc Therapy, Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy of Lung Cancers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ming, X; Zhang, Y; Yale University, New Haven, CT, US

    2014-06-01

    Purpose: The cardiac toxicity for lung cancer patients, each treated with dynamic conformal arc therapy (DAT), intensity-modulated radiation therapy (IMRT), or volumetric modulated arc therapy (VMAT) is investigated. Methods: 120 lung patients were selected for this study: 25 treated with DAT, 50 with IMRT and 45 with VMAT. For comparison, all plans were generated in the same treatment planning system, normalized such that the 100% isodose lines encompassed 95% of planning target volume. The plan quality was evaluated in terms of homogeneity index (HI) and 95% conformity index (%95 CI) for target dose coverage and mean dose, maximum dose, V{submore » 30} Gy as well as V{sub 5} Gy for cardiac toxicity analysis. Results: When all the plans were analyzed, the VMAT plans offered the best target coverage with 95% CI = 0.992 and HI = 1.23. The DAT plans provided the best heart sparing with mean heart dose = 2.3Gy and maximum dose = 11.6Gy, as compared to 5.7 Gy and 31.1 Gy by IMRT as well as 4.6 Gy and 30.9 Gy by VMAT. The mean V30Gy and V5Gy of the heart in the DAT plans were up to 11.7% lower in comparison to the IMRT and VMAT plans. When the tumor volume was considered, the VMAT plans spared up to 70.9% more doses to the heart when the equivalent diameter of the tumor was larger than 4cm. Yet the maximum dose to the heart was reduced the most in the DAT plans with up to 139.8% less than that of the other two plans. Conclusion: Overall, the VMAT plans achieved the best target coverage among the three treatment modalities, and would spare the heart the most for the larger tumors. The DAT plans appeared advantageous in delivering the least maximum dose to the heart as compared to the IMRT and VMAT plans.« less

  4. Volumetric modulated arc therapy planning for primary prostate cancer with selective intraprostatic boost determined by 18F-choline PET/CT.

    PubMed

    Kuang, Yu; Wu, Lili; Hirata, Emily; Miyazaki, Kyle; Sato, Miles; Kwee, Sandi A

    2015-04-01

    This study evaluated expected tumor control and normal tissue toxicity for prostate volumetric modulated arc therapy (VMAT) with and without radiation boosts to an intraprostatically dominant lesion (IDL), defined by (18)F-choline positron emission tomography/computed tomography (PET/CT). Thirty patients with localized prostate cancer underwent (18)F-choline PET/CT before treatment. Two VMAT plans, plan79 Gy and plan100-105 Gy, were compared for each patient. The whole-prostate planning target volume (PTVprostate) prescription was 79 Gy in both plans, but plan100-105 Gy added simultaneous boost doses of 100 Gy and 105 Gy to the IDL, defined by 60% and 70% of maximum prostatic uptake on (18)F-choline PET (IDLsuv60% and IDLsuv70%, respectively, with IDLsuv70% nested inside IDLsuv60% to potentially enhance tumor specificity of the maximum point dose). Plan evaluations included histopathological correspondence, isodose distributions, dose-volume histograms, tumor control probability (TCP), and normal tissue complication probability (NTCP). Planning objectives and dose constraints proved feasible in 30 of 30 cases. Prostate sextant histopathology was available for 28 cases, confirming that IDLsuv60% adequately covered all tumor-bearing prostate sextants in 27 cases and provided partial coverage in 1 case. Plan100-105 Gy had significantly higher TCP than plan79 Gy across all prostate regions for α/β ratios ranging from 1.5 Gy to 10 Gy (P<.001 for each case). There were no significant differences in bladder and femoral head NTCP between plans and slightly lower rectal NTCP (endpoint: grade ≥ 2 late toxicity or rectal bleeding) was found for plan100-105 Gy. VMAT can potentially increase the likelihood of tumor control in primary prostate cancer while observing normal tissue tolerances through simultaneous delivery of a steep radiation boost to a (18)F-choline PET-defined IDL. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Safety and Immunogenicity of the HPV-16/18 AS04-adjuvanted Vaccine in 4-6-year-old Girls: Results to Month 12 From a Randomized Trial.

    PubMed

    Lin, Lan; Parra, Mercedes Macias; Sierra, Victor Y; Cespedes, Albino Salas; Granados, Maria Angelica; Luque, Adriana; Damaso, Silvia; Castrejon Alba, Maria Mercedes; Romano-Mazzotti, Luis; Struyf, Frank

    2018-04-01

    The burden of cervical cancer caused by human papillomavirus (HPV) is high in Latin America. The suboptimal HPV vaccination coverage in adolescents could be improved by pediatric immunization. HPV vaccination has not yet been reported in girls <9 years of age. This ongoing phase III, controlled, randomized, single-blind, multicenter study conducted in Colombia, Mexico and Panama (NCT01627561) evaluated the safety and immunogenicity of AS04-HPV-16/18 vaccine in 4-6-year-old girls. Healthy girls (randomized 1:1) received either 2 doses of AS04-HPV-16/18 vaccine (HPV group, N=74) or 1 dose of each measles-mumps-rubella and diphtheria-tetanus-acellular-pertussis vaccines (control group, N=74) 6 months apart. We report the safety and serum anti-HPV-16 and anti-HPV-18 antibodies (measured by enzyme-linked immunosorbent assay) up to 6 months postvaccination, that is, month (M) 12. Injection site pain was the most frequently reported solicited local symptom in HPV vaccinees. The incidence of other solicited and unsolicited symptoms after each vaccination was similar between the HPV and control group. Until M12, 1 girl in the HPV group and 2 in the control group reported serious adverse events; all serious adverse events were assessed as unrelated to study vaccines. No potential immune-mediated diseases were identified. All girls seroconverted for both antigens after 2 doses of AS04-HPV-16/18. In initially seronegative girls, anti-HPV-16 geometric mean concentrations were 20080.0 enzyme-linked immunosorbent assay units (EU)/mL at M7 and 3246.5 EU/mL at M12; anti-HPV-18 geometric mean concentrations were 10621.8 EU/mL at M7 and 1216.6 EU/mL at M12. Two-dose vaccination with AS04-HPV-16/18 was well tolerated and induced adequate antibody responses in 4-6-year-old girls.

  6. SU-C-210-02: Impact of Intrafractional Motion On TomoTherapy Stereotactic Body Radiotherapy (SBRT) 4D Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lian, J; Matney, J; Chao, E

    2015-06-15

    Purpose: TomoTherapy treatment has unique challenges in handling intrafractional motion compared to conventional LINAC. This study is aimed to gain a realistic and quantitative understanding of motion impact on TomoTherapy SBRT treatment of lung and prostate cancer patients. Methods: A 4D dose engine utilizing GPUs and including motion during treatment was developed for the efficient simulation of TomoTherapy delivered dosimetry. Two clinical CyberKnife lung cases with respiratory motion tracking and two prostate cases with a slower non-periodical organ motion treated by LINAC plus Calypso tracking were used in the study. For each disease site, one selected case has an averagemore » motion (6mm); the other has a large motion (10mm for lung and 15mm for prostate). SBRT of lung and prostate cases were re-planned on TomoTherapy with 12 Gyx4 fractions and 7Gyx5 fractions, respectively, all with 95% PTV coverage. Each case was planned with 4 jaw settings: 1) conventional 1cm static, 2) 2.5cm static, 3) 2.5cm dynamic, and 4) 5cm dynamic. The intrafractional rigid motion of the target was applied in the dose calculation of individual fractions of each plan and total dose was accumulated from multiple fractions. Results: For 1cm static jaw plans with motions applied, PTV coverage is related to motion type and amplitude. For SBRT patients with average motion (6mm), the PTV coverage remains > 95% for lung case and 74% for prostate case. For cases with large motion, PTV coverage drops to 61% for lung SBRT and 49% for prostate SBRT. Plans with other jaws improve uniformity of moving target, but still suffer from poor PTV coverage (< 70%). Conclusion: TomoTherapy lung SBRT is less motion-impacted when average amplitude of respiratory-induced intrafractional motion is present (6mm). When motion is large and/or non-periodic (prostate), all studied plans lead to significantly decreased target coverage in actual delivered dosimetry.« less

  7. TU-AB-BRB-01: Coverage Evaluation and Probabilistic Treatment Planning as a Margin Alternative

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siebers, J.

    The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. Themore » treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.« less

  8. TU-AB-BRB-03: Coverage-Based Treatment Planning to Accommodate Organ Deformable Motions and Contouring Uncertainties for Prostate Treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, H.

    The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. Themore » treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.« less

  9. TU-AB-BRB-00: New Methods to Ensure Target Coverage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2015-06-15

    The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. Themore » treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.« less

  10. Three-dimensional dose verification of the clinical application of gamma knife stereotactic radiosurgery using polymer gel and MRI.

    PubMed

    Papagiannis, P; Karaiskos, P; Kozicki, M; Rosiak, J M; Sakelliou, L; Sandilos, P; Seimenis, I; Torrens, M

    2005-05-07

    This work seeks to verify multi-shot clinical applications of stereotactic radiosurgery with a Leksell Gamma Knife model C unit employing a polymer gel-MRI based experimental procedure, which has already been shown to be capable of verifying the precision and accuracy of dose delivery in single-shot gamma knife applications. The treatment plan studied in the present work resembles a clinical treatment case of pituitary adenoma using four 8 mm and one 14 mm collimator helmet shots to deliver a prescription dose of 15 Gy to the 50% isodose line (30 Gy maximum dose). For the experimental dose verification of the treatment plan, the same criteria as those used in the clinical treatment planning evaluation were employed. These included comparison of measured and GammaPlan calculated data, in terms of percentage isodose contours on axial, coronal and sagittal planes, as well as 3D plan evaluation criteria such as dose-volume histograms for the target volume, target coverage and conformity indices. Measured percentage isodose contours compared favourably with calculated ones despite individual point fluctuations at low dose contours (e.g., 20%) mainly due to the effect of T2 measurement uncertainty on dose resolution. Dose-volume histogram data were also found in a good agreement while the experimental results for the percentage target coverage and conformity index were 94% and 1.17 relative to corresponding GammaPlan calculations of 96% and 1.12, respectively. Overall, polymer gel results verified the planned dose distribution within experimental uncertainties and uncertainty related to the digitization process of selected GammaPlan output data.

  11. A mystery caller evaluation of Medicaid staff responses about state coverage of abortion care.

    PubMed

    Dennis, Amanda; Blanchard, Kelly

    2012-03-01

    The Hyde Amendment prohibits federal Medicaid funding for abortion except when a woman is seeking an abortion for a pregnancy that is the result of rape or incest, or that threatens her life. We investigated how Medicaid staff in 17 states responded to inquiries about coverage for abortion in the few circumstances that qualify for federal Medicaid funding. Using a mystery caller approach, we surveyed Medicaid staff about the availability of abortion coverage, the process for obtaining coverage, and the associated costs for an abortion in circumstances of rape and life endangerment in five states where Medicaid coverage should be available to cover most abortions and in 12 states with restrictions on the circumstances under which Medicaid funding can be used for abortion. We were able to complete 82% of surveys. Medicaid staff definitively provided information about the availability of coverage that was consistent with state policies in 64% of surveys. However, 52% of staff reported that coverage could be difficult to obtain and that rigorous documentation of the circumstances of the abortion was required. Information about copays for abortion was given in 78% of surveys. We subjectively rated the caller's experience with Medicaid staff as excellent during 32% of the surveys, adequate in 61% of surveys, and poor in 7% of surveys. Medicaid staff provided inconsistent information that was often discouraging of women seeking abortion coverage, suggesting that women may have difficulties obtaining accurate information about Medicaid coverage of abortion, which may deter access to care. Copyright © 2012 Jacobs Institute of Women

  12. Pediatric chest and abdominopelvic CT: organ dose estimation based on 42 patient models.

    PubMed

    Tian, Xiaoyu; Li, Xiang; Segars, W Paul; Paulson, Erik K; Frush, Donald P; Samei, Ehsan

    2014-02-01

    To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. The institutional review board approved this HIPAA-compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0-16 years; weight range, 2-80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDI(vol)). The relationships between CTDI(vol)-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. For organs within the image coverage, CTDI(vol)-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R(2) > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%-32%) mainly because of the effect of overranging. It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDI(vol). These CTDI(vol)-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice. © RSNA, 2013.

  13. Social mobilisation, consent and acceptability: a review of human papillomavirus vaccination procedures in low and middle-income countries.

    PubMed

    Kabakama, Severin; Gallagher, Katherine E; Howard, Natasha; Mounier-Jack, Sandra; Burchett, Helen E D; Griffiths, Ulla K; Feletto, Marta; LaMontagne, D Scott; Watson-Jones, Deborah

    2016-08-19

    Social mobilisation during new vaccine introductions encourages acceptance, uptake and adherence to multi-dose schedules. Effective communication is considered especially important for human papillomavirus (HPV) vaccine, which targets girls of an often-novel age group. This study synthesised experiences and lessons learnt around social mobilisation, consent, and acceptability during 55 HPV vaccine demonstration projects and 8 national programmes in 37 low and middle-income countries (LMICs) between January 2007 and January 2015. A qualitative study design included: (i) a systematic review, in which 1,301 abstracts from five databases were screened and 41 publications included; (ii) soliciting 124 unpublished documents from governments and partner institutions; and (iii) conducting 27 key informant interviews. Data were extracted and analysed thematically. Additionally, first-dose coverage rates were categorised as above 90 %, 90-70 %, and below 70 %, and cross-tabulated with mobilisation timing, message content, materials and methods of delivery, and consent procedures. All but one delivery experience achieved over 70 % first-dose coverage; 60 % achieved over 90 %. Key informants emphasized the benefits of starting social mobilisation early and actively addressing rumours as they emerged. Interactive communication with parents appeared to achieve higher first-dose coverage than non-interactive messaging. Written parental consent (i.e., opt-in), though frequently used, resulted in lower reported coverage than implied consent (i.e., opt-out). Protection against cervical cancer was the primary reason for vaccine acceptability, whereas fear of adverse effects, exposure to rumours, lack of project/programme awareness, and schoolgirl absenteeism were major reasons for non-vaccination. Despite some challenges in obtaining parental consent and addressing rumours, experiences indicated effective social mobilisation and high HPV vaccine acceptability in LMICs. Social mobilisation, consent, and acceptability lessons were consistent across world regions and HPV vaccination projects/programmes. These can be used to guide HPV vaccination communication strategies without additional formative research.

  14. Dosimetric comparison between step-shoot intensity-modulated radiotherapy and volumetric-modulated arc therapy for upper thoracic and cervical esophageal carcinoma.

    PubMed

    Gao, Min; Li, Qilin; Ning, Zhonghua; Gu, Wendong; Huang, Jin; Mu, Jinming; Pei, Honglei

    2016-01-01

    To compare and analyze the dosimetric characteristics of volumetric modulated arc therapy (VMAT) vs step-shoot intensity-modulated radiation therapy (sIMRT) for upper thoracic and cervical esophageal carcinoma. Single-arc VMAT (VMAT1), dual-arc VMAT (VMAT2), and 7-field sIMRT plans were designed for 30 patients with upper thoracic or cervical esophageal carcinoma. Planning target volume (PTV) was prescribed to 50.4Gy in 28 fractions, and PTV1 was prescribed to 60Gy in 28 fractions. The parameters evaluated included dose homogeneity and conformality, dose to organs at risk (OARs), and delivery efficiency. (1) In comparison to sIMRT, VMAT provided a systematic improvement in PTV1 coverage. The homogeneity index of VMAT1 was better than that of VMAT2. There were no significant differences among sIMRT, VMAT1, and VMAT2 in PTV coverage. (2) VMAT1 and VMAT2 reduced the maximum dose of spinal cord as compared with sIMRT (p < 0.05). The rest dose-volume characteristics of OARs were similar. (3) Monitor units of VMAT2 and VMAT1 were more than sIMRT. However, the treatment time of VMAT1, VMAT2, and sIMRT was (2.0 ± 0.2), (2.8 ± 0.3), and (9.8 ± 0.8) minutes, respectively. VMAT1 was the fastest, and the difference was statistically significant. In the treatment of upper thoracic and cervical esophageal carcinoma by the AXESSE linac, compared with 7-field sIMRT, VMAT showed better PTV1 coverage and superior spinal cord sparing. Single-arc VMAT had similar target volume coverage and the sparing of OAR to dual-arc VMAT, with shortest treatment time and highest treatment efficiency in the 3 kinds of plans. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  15. Theoretical Benefits of Dynamic Collimation in Pencil Beam Scanning Proton Therapy for Brain Tumors: Dosimetric and Radiobiological Metrics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moignier, Alexandra, E-mail: alexandra-moignier@uiowa.edu; Gelover, Edgar; Wang, Dongxu

    Purpose: To quantify the dosimetric benefit of using a dynamic collimation system (DCS) for penumbra reduction during the treatment of brain tumors by pencil beam scanning proton therapy (PBS PT). Methods and Materials: Collimated and uncollimated brain treatment plans were created for 5 patients previously treated with PBS PT and retrospectively enrolled in an institutional review board–approved study. The in-house treatment planning system, RDX, was used to generate the plans because it is capable of modeling both collimated and uncollimated beamlets. The clinically delivered plans were reproduced with uncollimated plans in terms of target coverage and organ at risk (OAR) sparingmore » to ensure a clinically relevant starting point, and collimated plans were generated to improve the OAR sparing while maintaining target coverage. Physical and biological comparison metrics, such as dose distribution conformity, mean and maximum doses, normal tissue complication probability, and risk of secondary brain cancer, were used to evaluate the plans. Results: The DCS systematically improved the dose distribution conformity while preserving the target coverage. The average reduction of the mean dose to the 10-mm ring surrounding the target and the healthy brain were 13.7% (95% confidence interval [CI] 11.6%-15.7%; P<.0001) and 25.1% (95% CI 16.8%-33.4%; P<.001), respectively. This yielded an average reduction of 24.8% (95% CI 0.8%-48.8%; P<.05) for the brain necrosis normal tissue complication probability using the Flickinger model, and 25.1% (95% CI 16.8%-33.4%; P<.001) for the risk of secondary brain cancer. A general improvement of the OAR sparing was also observed. Conclusion: The lateral penumbra reduction afforded by the DCS increases the normal tissue sparing capabilities of PBS PT for brain cancer treatment while preserving target coverage.« less

  16. 4D CT-based Treatment Planning for Intensity-Modulated Radiation Therapy and Proton Therapy for Distal Esophagus Cancer

    PubMed Central

    Zhang, Xiaodong; Zhao, Kuai-Le; Guerrero, Thomas M.; McGuire, Sean E.; Yaremko, Brian; Komaki, Ritsuko; Cox, James D.; Hui, Zhouguang; Li, Yupeng; Newhauser, Wayne D.; Mohan, Radhe; Liao, Zhongxing

    2008-01-01

    Purpose To compare three-dimensional (3D) and 4D computed tomography (CT)– based treatment plans for proton therapy or intensity-modulated radiation therapy (IMRT) for esophageal cancer in terms of doses to the lung, heart, and spinal cord and variations in target coverage and normal tissue sparing. Materials and Methods IMRT and proton plans for 15 patients with distal esophageal cancer were designed from the 3D average CT scans and then recalculated on 10 4D CT data sets. Dosimetric data were compared for tumor coverage and normal tissue sparing. Results Compared with IMRT, median lung volumes exposed to 5,10, and 20 Gy and mean lung dose were reduced by 35.6%, 20.5%,5.8%, and 5.1 Gy for a two-beam proton plan and by 17.4%,8.4%,5%, and 2.9 Gy for a three-beam proton plan. The greater lung sparing in the two-beam proton plan was achieved at the expense of less conformity to the target (conformity index CI=1.99) and greater irradiation of the heart (heart-V40=41.8%) compared with the IMRT plan(CI=1.55, heart-V40=35.7%) or the three-beam proton plan (CI=1.46, heart-V40=27.7%). Target coverage differed by more than 2% between the 3D and 4D plans for patients with substantial diaphragm motion in the three-beam proton and IMRT plans. The difference in spinal cord maximum dose between 3D and 4D plans could exceed 5 Gy for the proton plans partly owing to variations in stomach gas-filling. Conclusions Proton therapy provided significantly better sparing of lung than did IMRT. Diaphragm motion and stomach gas-filling must be considered in evaluating target coverage and cord doses. PMID:18722278

  17. Health and economic impact of human papillomavirus 16 and 18 vaccination of preadolescent girls and cervical cancer screening of adult women in Peru.

    PubMed

    Goldie, Sue J; Levin, Carol; Mosqueira-Lovón, N Rocio; Ortendahl, Jesse; Kim, Jane; O'Shea, Meredith; Diaz Sanchez, Mireia; Mendoza Araujo, Maria Ana

    2012-12-01

    To estimate the benefits, cost-effectiveness (i.e., value for money), and required financial costs (e.g., affordability) of adding human papillomavirus (HPV) vaccination to Peru's cervical cancer screening program. Evidence (e.g., coverage, delivery costs) from an HPV vaccination demonstration project conducted in Peru was combined with epidemiological data in an empirically calibrated mathematical model to assess screening (HPV DNA testing three to five times per lifetime) and HPV vaccination under different cost, coverage, and efficacy assumptions. Model outcomes included lifetime risk of cancer reduction, cancer cases averted, lives saved, average life expectancy gains, short-term financial costs, and discounted long-term economic costs. Status quo low levels of screening (e.g., cytologic screening at 10.0% coverage) reduced lifetime risk of cervical cancer by 11.9%, compared to not screening. Adding vaccination of preadolescent girls at a coverage achieved in the demonstration program (82.0%) produced an additional 46.1% reduction, and would cost less than US$ 500 per year of life saved (YLS) at ~US$ 7/dose or ~US$ 1 300 at ~US$ 20/dose. One year of vaccination was estimated to cost ~US$ 5 million at ~US$ 5/dose or ~US$ 16 million at ~US$ 20/dose, including programmatic costs. Enhanced screening in adult women combined with preadolescent vaccination had incremental cost-effectiveness ratios lower than Peru's 2005 per capita gross domestic product (GDP; US$ 2 852, in 2009 US$), and would be considered cost-effective. Preadolescent HPV vaccination, followed by enhanced HPV DNA screening in adult women, could prevent two out of three cervical cancer deaths. Several strategies would be considered "good value" for resources invested, provided vaccine prices are low. While financial costs imply substantial immediate investments, the high-value payoff should motivate creative mechanisms for financing and scale-up of delivery programs.

  18. Four-dimensional computed tomography-based treatment planning for intensity-modulated radiation therapy and proton therapy for distal esophageal cancer.

    PubMed

    Zhang, Xiaodong; Zhao, Kuai-le; Guerrero, Thomas M; McGuire, Sean E; Yaremko, Brian; Komaki, Ritsuko; Cox, James D; Hui, Zhouguang; Li, Yupeng; Newhauser, Wayne D; Mohan, Radhe; Liao, Zhongxing

    2008-09-01

    To compare three-dimensional (3D) and four-dimensional (4D) computed tomography (CT)-based treatment plans for proton therapy or intensity-modulated radiation therapy (IMRT) for esophageal cancer in terms of doses to the lung, heart, and spinal cord and variations in target coverage and normal tissue sparing. The IMRT and proton plans for 15 patients with distal esophageal cancer were designed from the 3D average CT scans and then recalculated on 10 4D CT data sets. Dosimetric data were compared for tumor coverage and normal tissue sparing. Compared with IMRT, median lung volumes exposed to 5, 10, and 20 Gy and mean lung dose were reduced by 35.6%, 20.5%, 5.8%, and 5.1 Gy for a two-beam proton plan and by 17.4%, 8.4%, 5%, and 2.9 Gy for a three-beam proton plan. The greater lung sparing in the two-beam proton plan was achieved at the expense of less conformity to the target (conformity index [CI], 1.99) and greater irradiation of the heart (heart-V40, 41.8%) compared with the IMRT plan(CI, 1.55, heart-V40, 35.7%) or the three-beam proton plan (CI, 1.46, heart-V40, 27.7%). Target coverage differed by more than 2% between the 3D and 4D plans for patients with substantial diaphragm motion in the three-beam proton and IMRT plans. The difference in spinal cord maximum dose between 3D and 4D plans could exceed 5 Gy for the proton plans partly owing to variations in stomach gas filling. Proton therapy provided significantly better sparing of lung than did IMRT. Diaphragm motion and stomach gas-filling must be considered in evaluating target coverage and cord doses.

  19. Dosimetric comparison between step-shoot intensity-modulated radiotherapy and volumetric-modulated arc therapy for upper thoracic and cervical esophageal carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, Min; Li, Qilin; Ning, Zhonghua

    2016-07-01

    To compare and analyze the dosimetric characteristics of volumetric modulated arc therapy (VMAT) vs step-shoot intensity-modulated radiation therapy (sIMRT) for upper thoracic and cervical esophageal carcinoma. Single-arc VMAT (VMAT1), dual-arc VMAT (VMAT2), and 7-field sIMRT plans were designed for 30 patients with upper thoracic or cervical esophageal carcinoma. Planning target volume (PTV) was prescribed to 50.4 Gy in 28 fractions, and PTV1 was prescribed to 60 Gy in 28 fractions. The parameters evaluated included dose homogeneity and conformality, dose to organs at risk (OARs), and delivery efficiency. (1) In comparison to sIMRT, VMAT provided a systematic improvement in PTV1 coverage.more » The homogeneity index of VMAT1 was better than that of VMAT2. There were no significant differences among sIMRT, VMAT1, and VMAT2 in PTV coverage. (2) VMAT1 and VMAT2 reduced the maximum dose of spinal cord as compared with sIMRT (p < 0.05). The rest dose-volume characteristics of OARs were similar. (3) Monitor units of VMAT2 and VMAT1 were more than sIMRT. However, the treatment time of VMAT1, VMAT2, and sIMRT was (2.0 ± 0.2), (2.8 ± 0.3), and (9.8 ± 0.8) minutes, respectively. VMAT1 was the fastest, and the difference was statistically significant. In the treatment of upper thoracic and cervical esophageal carcinoma by the AXESSE linac, compared with 7-field sIMRT, VMAT showed better PTV1 coverage and superior spinal cord sparing. Single-arc VMAT had similar target volume coverage and the sparing of OAR to dual-arc VMAT, with shortest treatment time and highest treatment efficiency in the 3 kinds of plans.« less

  20. Development and Validation of a Behavioral Screener for Preschool-Age Children

    ERIC Educational Resources Information Center

    DiStefano, Christine A.; Kamphaus, Randy W.

    2007-01-01

    The purpose of this study was to document the development of a short behavioral scale that could be used to assess preschoolers' behavior while still retaining adequate scale coverage, reliability, and validity. Factor analysis and item analysis techniques were applied to data from a nationally representative, normative database to create a…

  1. 78 FR 62506 - TRICARE; Coverage of Care Related to Non-Covered Initial Surgery or Treatment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-22

    ... Supplemental Health Care Program waiver. This proposed rule is necessary to protect TRICARE beneficiaries from...-covered surgery or treatment was necessary to assure adequate availability of health care to the Active... Regulatory Actions Under the TRICARE private sector health care program, certain conditions and treatments...

  2. Access to Health Care: Does Neighborhood Residential Instability Matter?

    ERIC Educational Resources Information Center

    Kirby, James B.; Kaneda, Toshiko

    2006-01-01

    Many Americans do not have access to adequate medical care. Previous research on this problem focuses primarily on individual-level determinants of access such as income and insurance coverage. The role of community-level factors in helping or hindering individuals in obtaining needed medical care, however, has not received much attention. We…

  3. Women and Minorities in Economics Textbooks: Are They Being Adequately Represented?

    ERIC Educational Resources Information Center

    Robson, Denise

    2001-01-01

    Examines 12 recent editions of principles of economics textbooks to determine the quantity of race- and gender-related material. Finds, in general, that there has been an increase in the quantitative coverage of race- and gender-related material as measured by the number of pages, names, and tables in the textbooks. (RLH)

  4. A Textbook Selection Process.

    ERIC Educational Resources Information Center

    Prosser, Daniel R.; Bondavalli, Bonnie J.

    In response to the problem facing college faculties of choosing textbooks that are both "readable" by students and adequate in content coverage, a text selection process has been developed that can be used with or without the aid of a reading specialist. The first step in the process, a preliminary check, examines each proposed text's publication…

  5. ASIS Thesaurus of Information Science and Librarianship. ASIS Monograph Series. Second Edition.

    ERIC Educational Resources Information Center

    Milstead, Jessica L., Ed.

    This thesaurus covers the fields of information science and librarianship to a depth that will adequately support indexing, with coverage of related and peripheral fields as warranted by the strength of their relationship to information science and librarianship. Among the related fields are computer science, linguistics, and behavioral and…

  6. Reporting the "Exodus": News Coverage of Teacher Shortage in Australian Newspapers

    ERIC Educational Resources Information Center

    Shine, Kathryn

    2015-01-01

    Many developed countries, including Australia, struggle to recruit and retain adequate numbers of school teachers. Over the past decade every Australian state has experienced teacher shortages and, at various times, there has been a national shortfall of qualified teaching staff. This paper considers the reporting of teacher shortage in four…

  7. Two Birds With One Stone: Estimating Population Vaccination Coverage From a Test-negative Vaccine Effectiveness Case-control Study.

    PubMed

    Doll, Margaret K; Morrison, Kathryn T; Buckeridge, David L; Quach, Caroline

    2016-10-15

    Vaccination program evaluation includes assessment of vaccine uptake and direct vaccine effectiveness (VE). Often examined separately, we propose a design to estimate rotavirus vaccination coverage using controls from a rotavirus VE test-negative case-control study and to examine coverage following implementation of the Quebec, Canada, rotavirus vaccination program. We present our assumptions for using these data as a proxy for coverage in the general population, explore effects of diagnostic accuracy on coverage estimates via simulations, and validate estimates with an external source. We found 79.0% (95% confidence interval, 74.3%, 83.0%) ≥2-dose rotavirus coverage among participants eligible for publicly funded vaccination. No differences were detected between study and external coverage estimates. Simulations revealed minimal bias in estimates with high diagnostic sensitivity and specificity. We conclude that controls from a VE case-control study may be a valuable resource of coverage information when reasonable assumptions can be made for estimate generalizability; high rotavirus coverage demonstrates success of the Quebec program. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  8. What Explains Divorced Women’s Poorer Health?: The Mediating Role of Health Insurance and Access to Health Care in a Rural Iowan Sample*

    PubMed Central

    Lavelle, Bridget; Lorenz, Frederick O.; Wickrama, K. A. S.

    2012-01-01

    The economic restructuring in rural areas in recent decades has been accompanied by rising marital instability. To examine the implications of the increase in divorce for the health of rural women, we examine how marital status predicts adequacy of health insurance coverage and health care access, and whether these factors help to account for the documented association between divorce and later illness. Analyzing longitudinal data from a cohort of over 400 married and recently divorced rural Iowan women, we decompose the total effect of divorce on physical illness a decade later using structural equation modeling. Divorced women are less likely to report adequate health insurance in the years following divorce, inhibiting their access to medical care and threatening their physical health. Full-time employment acts as a buffer against insurance loss for divorced women. The growth of marital instability in rural areas has had significant ramifications for women’s health; the decline of adequate health insurance coverage following divorce explains a component of the association between divorced status and poorer long-term health outcomes. PMID:23457418

  9. Treatment for preventing bleeding in people with haemophilia or other congenital bleeding disorders undergoing surgery.

    PubMed

    Coppola, Antonio; Windyga, Jerzy; Tufano, Antonella; Yeung, Cindy; Di Minno, Matteo Nicola Dario

    2015-02-09

    In people with haemophilia or other congenital bleeding disorders undergoing surgical interventions, haemostatic treatment is needed in order to correct the underlying coagulation abnormalities and minimise the bleeding risk. This treatment varies according to the specific haemostatic defect, its severity and the type of surgical procedure. The aim of treatment is to ensure adequate haemostatic coverage for as long as the bleeding risk persists and until wound healing is complete. To assess the effectiveness and safety of different haemostatic regimens (type, dose and duration, modality of administration and target haemostatic levels) administered in people with haemophilia or other congenital bleeding disorders for preventing bleeding complications during and after surgical procedures. We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group's Coagulopathies Trials Register, compiled from electronic database searches and handsearching of journals and conference abstract books. We also searched the reference lists of relevant articles and reviews.Date of the last search: 20 November 2014. Randomised and quasi-randomised controlled trials comparing any hemostatic treatment regimen to no treatment or to another active regimen in children and adults with haemophilia or other congenital bleeding disorders undergoing any surgical intervention. Two authors independently assessed trials (eligibility and risks of bias) and extracted data. Meta-analyses were performed on available and relevant data. Of the 16 identified trials, four (112 participants) were eligible for inclusion.Two trials evaluated 59 people with haemophilia A and B undergoing 63 dental extractions. Trials compared the use of a different type (tranexamic acid or epsilon-aminocaproic acid) and regimen of antifibrinolytic agents as haemostatic support to the initial replacement treatment. Neither trial specifically addressed mortality (one of this review's primary outcomes); however, in the frame of safety assessments, no fatal adverse events were reported. The second primary outcome of blood loss was assessed after surgery and these trials showed the reduction of blood loss and requirement of post-operative replacement treatment in people receiving antifibrinolytic agents compared with placebo. The remaining primary outcome of need for re-intervention was not reported by either trial.Two trials reported on 53 people with haemophilia A and B with inhibitors treated with different regimens of recombinant activated factor VII (rFVIIa) for haemostatic coverage of 33 major and 20 minor surgical interventions. Neither of the included trials specifically addressed any of the review's primary outcomes (mortality, blood loss and need for re-intervention). In one trial a high-dose rFVIIa regimen (90 μg/kg) was compared with a low-dose regimen (35 μg/kg); the higher dose showed increased haemostatic efficacy, in particular in major surgery, with shorter duration of treatment, similar total dose of rFVIIa administered and similar safety levels. In the second trial, bolus infusion and continuous infusion of rFVIIa were compared, showing similar haemostatic efficacy, duration of treatment and safety. There is insufficient evidence from randomised controlled trials to assess the most effective and safe haemostatic treatment to prevent bleeding in people with haemophilia or other congenital bleeding disorders undergoing surgical procedures. Ideally large, adequately powered, and well-designed randomised controlled trials would be needed, in particular to address the cost-effectiveness of such demanding treatments in the light of the increasing present economic constraints, and to explore the new challenge of ageing patients with haemophilia or other congenital bleeding disorders. However, performing such trials is always a complex task in this setting and presently does not appear to be a clinical and research priority. Indeed, major and minor surgeries are effectively and safely performed in these individuals in clinical practice, with the numerous national and international recommendations and guidelines providing regimens for treatment in this setting mainly based on data from observational, uncontrolled studies.

  10. β-Lactam Therapy for Methicillin-Susceptible Staphylococcus aureus Bacteremia: A Comparative Review of Cefazolin versus Antistaphylococcal Penicillins.

    PubMed

    Li, Julius; Echevarria, Kelly L; Traugott, Kristi A

    2017-03-01

    Methicillin-susceptible Staphylococcus aureus (MSSA) bacteremia is associated with high morbidity and mortality. Traditionally, antistaphylococcal penicillins (ASPs) have been considered the agents of choice for the treatment of MSSA bacteremia. Vancomycin has been demonstrated to have poorer outcomes in several studies and is only recommended for patients with severe penicillin allergies. Although cefazolin is considered as an alternative to the ASPs for patients with nonsevere penicillin allergies, cefazolin offers several pharmacologic advantages over ASPs, such as more convenient dosing regimens, and antimicrobial stewardship programs are increasingly using cefazolin as the preferential agent for MSSA infections as part of cost-saving initiatives. Concerns about susceptibility to hydrolysis by type A β-lactamases, particularly at high inocula seen in deep-seated infections such as endocarditis; selective pressures from unnecessary gram-negative coverage; and lack of comparative clinical data have precluded recommending cefazolin as a first-line therapy for MSSA bacteremia. Recent clinical studies, however, have suggested similar clinical efficacy but better tolerability, with lower rates of discontinuation due to adverse drug reactions, of cefazolin compared with ASPs. Other variables, such as adequate source control (e.g., intravascular catheter removal, debridement, or drainage) and enhanced pharmacodynamics through aggressive cefazolin dosing, may mitigate the role of cefazolin inoculum effect and factor into determining improved clinical outcomes. In this review, we highlight the utility of cefazolin versus ASPs in the treatment of MSSA bacteremia with a focus on clinical efficacy and safety. © 2017 Pharmacotherapy Publications, Inc.

  11. Outbreak of mumps in a school setting, United Kingdom, 2013.

    PubMed

    Aasheim, Erlend T; Inns, Thomas; Trindall, Amy; Emmett, Lynsey; Brown, Kevin E; Williams, Chris J; Reacher, Mark

    2014-01-01

    Effective protection against mumps can be achieved through 2 doses of the measles-mumps-rubella (MMR) vaccine. However, outbreaks of mumps have recently been described among populations with high vaccination coverage, including 2 doses of MMR. Here we describe an outbreak at a school in the East of England, UK. The school was attended by 540 pupils aged 10-19 years and had 170 staff. In total, 28 cases of mumps (24 pupils and 4 staff) were identified during 10 January to 16 March 2013. Vaccination status was known in 25 of the cases, and among these 21 (84.0%) had a documented history of 2 doses of MMR while the remaining had a history of one dose (2/25 cases, 8.0%) or no doses (2/25, 8.0%) of MMR. An outbreak control team recommended that MMR vaccine should be offered to all pupils whose parents consented to it, regardless of previous vaccination status. Additional MMR vaccines were administered to 103 pupils, including 76 (73.8%) third doses of MMR. Offering an additional dose of MMR appeared to be acceptable to parents, and we found it feasible to administer the intervention in a timely manner with resources from the local Public Health Centre (Primary Care Trust). An additional dose of MMR to all individuals at risk can be considered as an acceptable control measure for mumps outbreaks in schools even if the vaccination coverage is high. However, further evidence on the effectiveness, acceptability, and safety of this intervention is needed.

  12. A case study of radiotherapy planning for Intensity Modulation Radiation Therapy for the whole scalp with matching electron treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sponseller, Patricia, E-mail: sponselp@uw.edu; Department of Radiation Oncology, University of Washington Medical Center, Seattle, WA; Paravathaneni, Upendra

    2013-07-01

    The purpose of this report is to communicate a technique to match an electron field to the dose distribution of an Intensity-Modulated Radiation Therapy (IMRT) plan. A patient with multiple areas of squamous cell carcinoma over the scalp was treated using 60 Gy in 2.0-Gy fractions to the entire scalp and first echelon nodes with multiple 6-MV photon fields. To deliver an adequate dose to the scalp, a custom 1.0-cm bolus helmet was fashioned using a solid piece of aquaplast. Along with the IMRT scalp treatment, a left zygoma area was treated with electrons matching the anterior border of themore » IMRT dose distribution. The border was matched by creating a left lateral field with the multileaf collimator shaped to the IMRT dose distribution. The result indicated an adequate dose to the skin match between the IMRT plan and the electron field. Results were confirmed using optically stimulated luminescence placed at the skin match area, so that the dose matched the prescription within 10%.« less

  13. Space Shuttle Communications Coverage Analysis for Thermal Tile Inspection

    NASA Technical Reports Server (NTRS)

    Kroll, Quin D.; Hwu, Shian U.; Upanavage, Matthew; Boster, John P.; Chavez, Mark A.

    2009-01-01

    The space shuttle ultra-high frequency Space-to-Space Communication System has to provide adequate communication coverage for astronauts who are performing thermal tile inspection and repair on the underside of the space shuttle orbiter (SSO). Careful planning and quantitative assessment are necessary to ensure successful system operations and mission safety in this work environment. This study assesses communication systems performance for astronauts who are working in the underside, non-line-of-sight shadow region on the space shuttle. All of the space shuttle and International Space Station (ISS) transmitting antennas are blocked by the SSO structure. To ensure communication coverage at planned inspection worksites, the signal strength and link margin between the SSO/ISS antennas and the extravehicular activity astronauts, whose line-of-sight is blocked by vehicle structure, was analyzed. Investigations were performed using rigorous computational electromagnetic modeling techniques. Signal strength was obtained by computing the reflected and diffracted fields along the signal propagation paths between transmitting and receiving antennas. Radio frequency (RF) coverage was determined for thermal tile inspection and repair missions using the results of this computation. Analysis results from this paper are important in formulating the limits on reliable communication range and RF coverage at planned underside inspection and repair worksites.

  14. Four-Dimensional Patient Dose Reconstruction for Scanned Ion Beam Therapy of Moving Liver Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richter, Daniel; TU Darmstadt, Darmstadt; Saito, Nami

    2014-05-01

    Purpose: Estimation of the actual delivered 4-dimensional (4D) dose in treatments of patients with mobile hepatocellular cancer with scanned carbon ion beam therapy. Methods and Materials: Six patients were treated with 4 fractions to a total relative biological effectiveness (RBE)–weighted dose of 40 Gy (RBE) using a single field. Respiratory motion was addressed by dedicated margins and abdominal compression (5 patients) or gating (1 patient). 4D treatment dose reconstructions based on the treatment records and the measured motion monitoring data were performed for the single-fraction dose and a total of 17 fractions. To assess the impact of uncertainties in the temporalmore » correlation between motion trajectory and beam delivery sequence, 3 dose distributions for varying temporal correlation were calculated per fraction. For 3 patients, the total treatment dose was formed from the fractional distributions using all possible combinations. Clinical target volume (CTV) coverage was analyzed using the volumes receiving at least 95% (V{sub 95}) and 107% (V{sub 107}) of the planned doses. Results: 4D dose reconstruction based on daily measured data is possible in a clinical setting. V{sub 95} and V{sub 107} values for the single fractions ranged between 72% and 100%, and 0% and 32%, respectively. The estimated total treatment dose to the CTV exhibited improved and more robust dose coverage (mean V{sub 95} > 87%, SD < 3%) and overdose (mean V{sub 107} < 4%, SD < 3%) with respect to the single-fraction dose for all analyzed patients. Conclusions: A considerable impact of interplay effects on the single-fraction CTV dose was found for most of the analyzed patients. However, due to the fractionated treatment, dose heterogeneities were substantially reduced for the total treatment dose. 4D treatment dose reconstruction for scanned ion beam therapy is technically feasible and may evolve into a valuable tool for dose assessment.« less

  15. Progress towards achieving and maintaining maternal and neonatal tetanus elimination in the African region.

    PubMed

    Ridpath, Alison Delano; Scobie, Heather Melissa; Shibeshi, Messeret Eshetu; Yakubu, Ahmadu; Zulu, Flint; Raza, Azhar Abid; Masresha, Balcha; Tohme, Rania

    2017-01-01

    Despite the availability of effective tetanus prevention strategies, as of 2016, Maternal and Neonatal Tetanus Elimination (MNTE) has not yet been achieved in 18 countries globally. In this paper, we review the status of MNTE in the World Health Organization African Region (AFR),and provide recommendations for achieving and maintaining MNTE in AFR. As of November 2016, 37 (79%) AFR countries have achieved MNTE, with 10 (21%) countries remaining. DTP3 coverage increased from 52% in 2000 to 76% in 2015. In 2015, coverage with at least 2 doses of tetanus containing vaccine (TT2+) and proportion of newborns protected at birth (PAB) were 69% and 77%, compared with 44% and 62% in 2000, respectively. Since 1999, over 79 million women of reproductive age (WRA) have been vaccinated with TT2+ through supplementary immunization activities (SIAs). Despite the progress, only 54% of births were attended by skilled birth attendants (SBAs), 5 (11%) countries provided the 3 WHO-recommended booster doses to both sexes, and about 5.5 million WRA still need to be reached with SIAs. Coverage disparities still exist between countries that have achieved MNTE and those that have not. In 2015, coverage with DTP3 and PAB were higher in MNTE countries compared with those yet to achieve MNTE: 84% vs. 68% and 86% vs. 69%, respectively. Challenges to achieving MNTE in the remaining AFR countries include weak health systems, competing priorities, insufficient funding, insecurity, and sub-optimal neonatal tetanus (NT) surveillance. To achieve and maintain MNTE in AFR, increasing SBAs and tetanus vaccination coverage, integrating tetanus vaccination with other opportunities (e.g., polio and measles campaigns, mother and child health days), and providing appropriately spaced booster doses are needed. Strengthening NT surveillance and conducting serosurveys would ensure appropriate targeting of MNTE activities and high-quality information for validating the achievement and maintenance of elimination.

  16. Progress towards achieving and maintaining maternal and neonatal tetanus elimination in the African region

    PubMed Central

    Ridpath, Alison Delano; Scobie, Heather Melissa; Shibeshi, Messeret Eshetu; Yakubu, Ahmadu; Zulu, Flint; Raza, Azhar Abid; Masresha, Balcha; Tohme, Rania

    2017-01-01

    Despite the availability of effective tetanus prevention strategies, as of 2016, Maternal and Neonatal Tetanus Elimination (MNTE) has not yet been achieved in 18 countries globally. In this paper, we review the status of MNTE in the World Health Organization African Region (AFR),and provide recommendations for achieving and maintaining MNTE in AFR. As of November 2016, 37 (79%) AFR countries have achieved MNTE, with 10 (21%) countries remaining. DTP3 coverage increased from 52% in 2000 to 76% in 2015. In 2015, coverage with at least 2 doses of tetanus containing vaccine (TT2+) and proportion of newborns protected at birth (PAB) were 69% and 77%, compared with 44% and 62% in 2000, respectively. Since 1999, over 79 million women of reproductive age (WRA) have been vaccinated with TT2+ through supplementary immunization activities (SIAs). Despite the progress, only 54% of births were attended by skilled birth attendants (SBAs), 5 (11%) countries provided the 3 WHO-recommended booster doses to both sexes, and about 5.5 million WRA still need to be reached with SIAs. Coverage disparities still exist between countries that have achieved MNTE and those that have not. In 2015, coverage with DTP3 and PAB were higher in MNTE countries compared with those yet to achieve MNTE: 84% vs. 68% and 86% vs. 69%, respectively. Challenges to achieving MNTE in the remaining AFR countries include weak health systems, competing priorities, insufficient funding, insecurity, and sub-optimal neonatal tetanus (NT) surveillance. To achieve and maintain MNTE in AFR, increasing SBAs and tetanus vaccination coverage, integrating tetanus vaccination with other opportunities (e.g., polio and measles campaigns, mother and child health days), and providing appropriately spaced booster doses are needed. Strengthening NT surveillance and conducting serosurveys would ensure appropriate targeting of MNTE activities and high-quality information for validating the achievement and maintenance of elimination. PMID:29296159

  17. Dosimetric Implications of Residual Tracking Errors During Robotic SBRT of Liver Metastases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chan, Mark; Tuen Mun Hospital, Hong Kong; Grehn, Melanie

    Purpose: Although the metric precision of robotic stereotactic body radiation therapy in the presence of breathing motion is widely known, we investigated the dosimetric implications of breathing phase–related residual tracking errors. Methods and Materials: In 24 patients (28 liver metastases) treated with the CyberKnife, we recorded the residual correlation, prediction, and rotational tracking errors from 90 fractions and binned them into 10 breathing phases. The average breathing phase errors were used to shift and rotate the clinical tumor volume (CTV) and planning target volume (PTV) for each phase to calculate a pseudo 4-dimensional error dose distribution for comparison with themore » original planned dose distribution. Results: The median systematic directional correlation, prediction, and absolute aggregate rotation errors were 0.3 mm (range, 0.1-1.3 mm), 0.01 mm (range, 0.00-0.05 mm), and 1.5° (range, 0.4°-2.7°), respectively. Dosimetrically, 44%, 81%, and 92% of all voxels differed by less than 1%, 3%, and 5% of the planned local dose, respectively. The median coverage reduction for the PTV was 1.1% (range in coverage difference, −7.8% to +0.8%), significantly depending on correlation (P=.026) and rotational (P=.005) error. With a 3-mm PTV margin, the median coverage change for the CTV was 0.0% (range, −1.0% to +5.4%), not significantly depending on any investigated parameter. In 42% of patients, the 3-mm margin did not fully compensate for the residual tracking errors, resulting in a CTV coverage reduction of 0.1% to 1.0%. Conclusions: For liver tumors treated with robotic stereotactic body radiation therapy, a safety margin of 3 mm is not always sufficient to cover all residual tracking errors. Dosimetrically, this translates into only small CTV coverage reductions.« less

  18. SU-F-19A-11: Retrospective Evaluation of Thermal Coverage by Thermobrachytherapy Seed Arrangements of Clinical LDR Prostate Implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warrell, G; Shvydka, D; Chen, C

    Purpose: The superiority of a properly-administered combination of radiation therapy and hyperthermia over radiation alone in treatment of human cancers has been demonstrated in multiple studies examining radiobiology, local control, and survival. Unfortunately, hyperthermia is not yet a common modality in oncology practice, due in part to the technical difficulty of heating a deep-seated target volume to sufficient temperature. To address this problem, our group has invented a thermobrachytherapy (TB) seed based on a commonly-used low dose-rate permanent brachytherapy seed for implant in solid tumors. Instead of the tungsten radiographic marker of the standard seed, the TB seed contains onemore » of a self-regulating ferromagnetic alloy. Placement of a patient implanted with such seeds in an oscillating magnetic field generates heat via induction of eddy currents. We present the results of studies of the capability of clinically-realistic TB seed arrangements to adequately heat defined target volumes. Methods: Seed distributions for several past LDR prostate permanent implant brachytherapy patients were reproduced in the finite element analysis software package COMSOL Multiphysics 4.4, with the difference that TB seeds were modelled, rather than the radiation-only seeds actually used for their treatments. The implant geometries were mainly of the modified peripheral loading type; a range of prostatic volumes and blood perfusion rates likely to be seen in a clinical setting were examined. Results: According to the simulations, when distributed to optimize radiation dose, TB seeds also produce sufficient heat to provide thermal coverage of the target given proper selection of the magnetic field strength. However, the thermal distributions may be improved by additional use of hyperthermia-only seeds. Conclusion: A dual-modality seed intended as an alternative to and using the same implantation apparatus and technique as the standard LDR permanent implant seed has been successfully evaluated for its ability to provide sufficient hyperthermia in clinically-realistic implants. This work was partially supported by the National Institutes of Health (NIH) STTR Grant No. R41 CA153631-01A1.« less

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Yizhou, E-mail: yizhou.zhao@dal.ca; Moran, Kathryn; Yewondwossen, Mammo

    Three-dimensional (3D) printing is suitable for the fabrication of complex radiotherapy bolus. Although investigated from dosimetric and feasibility standpoints, there are few reports to date of its use for actual patient treatment. This study illustrates the versatile applications of 3D printing in clinical radiation oncology through a selection of patient cases, namely, to create bolus for photon and modulated electron radiotherapy (MERT), as well as applicators for surface high-dose rate (HDR) brachytherapy. Photon boluses were 3D-printed to treat a recurrent squamous cell carcinoma (SCC) of the nasal septum and a basal cell carcinoma (BCC) of the posterior pinna. For amore » patient with a mycosis fungoides involving the upper face, a 3D-printed MERT bolus was used. To treat an SCC of the nose, a 3D-printed applicator for surface brachytherapy was made. The structures' fit to the anatomy and the radiotherapy treatment plans were assessed. Based on the treatment planning computed tomography (CT), the size of the largest air gap at the interface of the 3D-printed structure was 3 mm for the SCC of the nasal septum, 3 mm for the BCC of the pinna, 2 mm for the mycosis fungoides of the face, and 2 mm for the SCC of the nose. Acceptable treatment plans were obtained for the SCC of the nasal septum (95% isodose to 99.8% of planning target volume [PTV]), the BCC of the pinna (95% isodose to 97.7% of PTV), and the mycosis fungoides of the face (90% isodose to 92.5% of PTV). For the latter, compared with a plan with a uniform thickness bolus, the one featuring the MERT bolus achieved relative sparing of all the organs at risk (OARs) distal to the target volume, while maintaining similar target volume coverage. The surface brachytherapy plan for the SCC of the nose had adequate coverage (95% isodose to 95.6% of clinical target volume [CTV]), but a relatively high dose to the left eye, owing to its proximity to the tumor. 3D printing can be implemented effectively in the clinical setting to create highly conformal bolus for photon and MERT, as well as applicators for surface brachytherapy.« less

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, S; Ellis, R; Traughber, B

    Purpose: Treating gynecological cancers with interstitial high-dose-rate (HDR) brachytherapy requires precise reconstruction of catheter positions to obtain accurate dosimetric plans. In this study, we investigated the degree of reproducibility of dosimetric plans for Syed HDR brachytherapy. Methods: We randomly selected five patients having cervix-vaginal cancer who were recently treated in our clinic with interstitial HDR brachytherapy with a prescription dose of 25–30 Gy in five fractions. Interstitial needles/catheters were placed under fluoroscopic guidance and intra-operative 3T MRI scan was performed to confirm the desired catheter placement for adequate target volume coverage. A CT scan was performed and fused with themore » MRI for delineating high-risk CTV (HR-CTV), intermediate-risk CTV (IR-CTV) and OARs. HDR treatment plans were generated using Oncentra planning software. A single plan was used for all five fractions of treatment for each patient. For this study, we took the original clinical plan and removed all the reconstructed catheters from the plan keeping the original contours unchanged. Then, we manually reconstructed all the catheters and entered the same dwell time from the first original clinical plan. The dosimetric parameters studied were: D90 for HR-CTV and IR-CV, and D2cc for bladder, rectum, sigmoid and bowel. Results: The mean of absolute differences in dosimetric coverage (D90) were (range): 1.3% (1.0–2.0%) and 2.0% (0.9–3.6%) for HR-CTV and IR-CTV, respectively. In case of OARs, the mean of absolute variations in D2cc were (range): 4.7% (0.7–8.9%) for bladder, 1.60% (0.3–3.2%) for rectum, 1.6% (0–3.9%) for sigmoid, and 1.8% (0–5.1%) for bowel. Conclusion: Overall, the reproducibility of interstitial HDR plans was within clinically acceptable limit. Observed maximum variation in D2cc for bladder. If number of catchers and dwell points were relatively low or any one catheter was heavily loaded, then reproducibility of the plan was more sensitive to the accuracy of catheter reconstruction.« less

  1. SU-E-J-39: Dosimetric Benefit of Implanted Marker-Based CBCT Setup for Definitive Prostatic Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhen, H; Wu, Z; Bluemenfeld, P

    Purpose Daily setup for definitive prostatic radiotherapy is challenged by suboptimal visibility of the prostate boundary and daily variation of rectum shape and position. For patients with improved bowel preparation, we conducted a dosimetric comparison between prostate implanted marker (IM)-based daily setup and anterior rectal wall (ARW)-based setup, with the hypothesis that the former leads to adequate target coverage with better rectal sparing. Methods Five IMRT/VMAT prostate cases with implanted markers were selected for analysis. Daily CBCT showed improvement of the rectal volume compared to planning CT. For each patient, the prostate and rectum were contoured on three CBCT imagesmore » (fraction 5/15/25) with subsequent physician review. The CBCTs were then registered to a planning CT using IM-based registration. The deviation of ARW positions from planning CT to CBCT were analyzed at various sup-inf levels (−1.8 cm to 1.8 cm from level of prostate center). To estimate the potential dosimetric impact from ARW-based setup, the treatment plans were recalculated using A-P shifts ranging from −1mm to +6mm. Clinically important rectum DVH values including Dmax, D3cc and Dmean were computed. Results For the studied patients, we observed on average 32% rectum volume reduction from planning CT to CBCT. As a Results, the ARW on average shifts posteriorly by −1mm to +5mm, depending on the sup-inf level of observation, with larger shifts observed at more superior levels. Recalculation shows that when ARW shifts 1mm posteriorly, ARW-based CBCT setup leads to a 1.0%, 4.2%, and 3.2% increase in rectum Dmax, D3cc, and Dmean, respectively, compared to IM-based setup. The dosimetric deviations increase to 4.7%, 25.8% and 24.7% when ARW shifts 6mm posteriorly. No significant prostate-only dose difference was observed. Conclusion For patients with improved bowel preparation, IM-based CBCT setup leads to accurate prostate coverage along with significantly lower rectal dose, compared to ARW-based setup.« less

  2. Comparing proton treatment plans of pediatric brain tumors in two pencil beam scanning nozzles with different spot sizes

    PubMed Central

    Kralik, John C.; Xi, Liwen; Solberg, Timothy D.; Simone, Charles B.

    2015-01-01

    Target coverage and organ‐at‐risk sparing were compared for 22 pediatric patients with primary brain tumors treated using two distinct nozzles in pencil beam scanning (PBS) proton therapy. Consecutive patients treated at our institution using a PBS‐dedicated nozzle (DN) were replanned using a universal nozzle (UN) beam model and the original DN plan objectives. Various cranial sites were treated among the patients to prescription doses ranging from 45 to 54 Gy. Organs at risk (OARs) evaluated were patient‐dependent; 15 unique OARs were analyzed, all of which were assessed in at least 10 patients. Clinical target volume (CTV) coverage and organ sparing were compared for the two nozzles using dose‐volume histogram data. Statistical analysis using a confidence‐interval approach demonstrates that CTV coverage is equivalent for UN and DN plans within ±5% equivalence bounds. In contrast, average mean and maximum doses are significantly higher for nearly all 15 OARs in the UN plans. The average median increase over all OARs and patients is approximately 1.7 Gy, with an increase in the 25%–75% of 1.0–2.3 Gy; the median increase to the pituitary gland, temporal lobes, eyes and cochleas are 1.8, 1.7, 0.7, and 2.7 Gy, respectively. The CTV dose distributions fall off slower for UN than for the DN plans; hence, normal tissue structures in close proximity to CTVs receive higher doses in UN plans than in DN plans. The higher OAR doses in the UN plans are likely due to the larger spot profile in plans created with UN beams. In light of the high rates of toxicities in pediatric patients receiving cranial irradiation and in light of selected brain tumor types having high cure rates, this study suggests the smaller DN beam profile is preferable for the advantage of reducing dose to OARs. PACS number: 87.55.D‐ PMID:26699553

  3. Comparison of a new noncoplanar intensity-modulated radiation therapy technique for craniospinal irradiation with 3 coplanar techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, Anders T., E-mail: andehans@rm.dk; Lukacova, Slavka; Lassen-Ramshad, Yasmin

    2015-01-01

    When standard conformal x-ray technique for craniospinal irradiation is used, it is a challenge to achieve satisfactory dose coverage of the target including the area of the cribriform plate, while sparing organs at risk. We present a new intensity-modulated radiation therapy (IMRT), noncoplanar technique, for delivering irradiation to the cranial part and compare it with 3 other techniques and previously published results. A total of 13 patients who had previously received craniospinal irradiation with standard conformal x-ray technique were reviewed. New treatment plans were generated for each patient using the noncoplanar IMRT-based technique, a coplanar IMRT-based technique, and a coplanarmore » volumetric-modulated arch therapy (VMAT) technique. Dosimetry data for all patients were compared with the corresponding data from the conventional treatment plans. The new noncoplanar IMRT technique substantially reduced the mean dose to organs at risk compared with the standard radiation technique. The 2 other coplanar techniques also reduced the mean dose to some of the critical organs. However, this reduction was not as substantial as the reduction obtained by the noncoplanar technique. Furthermore, compared with the standard technique, the IMRT techniques reduced the total calculated radiation dose that was delivered to the normal tissue, whereas the VMAT technique increased this dose. Additionally, the coverage of the target was significantly improved by the noncoplanar IMRT technique. Compared with the standard technique, the coplanar IMRT and the VMAT technique did not improve the coverage of the target significantly. All the new planning techniques increased the number of monitor units (MU) used—the noncoplanar IMRT technique by 99%, the coplanar IMRT technique by 122%, and the VMAT technique by 26%—causing concern for leak radiation. The noncoplanar IMRT technique covered the target better and decreased doses to organs at risk compared with the other techniques. All the new techniques increased the number of MU compared with the standard technique.« less

  4. SU-F-T-392: Superior Brainstem and Cochlea Sparing with VMAT for Glioblastoma Multiforme

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Briere, TM; McAleer, MF; Levy, LB

    Purpose: Volumetric arc therapy (VMAT) can provide similar target coverage and normal tissue sparing as IMRT but with shorter treatment times. At our institution VMAT was adopted for the treatment glioblastoma multiforme (GBM) after a small number of test plans demonstrated its non-inferiority. In this study, we compare actual clinical treatment plans for a larger cohort of patients treated with either VMAT or IMRT. Methods: 90 GBM patients were included in this study, 45 treated with IMRT and 45 with VMAT. All planning target volumes (PTVs) were prescribed a dose of 50 Gy, with a simultaneous integrated boost to 60more » Gy. Most IMRT plans used 5 non-coplanar beams, while most VMAT plans used 2 coplanar beams. Statistical analysis was performed using Fisher’s exact test or the Wilcoxon-Mann-Whitney rank sum test. Included in the analysis were patient and treatment characteristics as well as the doses to the target volumes and organs at risk. Results: Treatment times for the VMAT plans were reduced by 5 minutes compared with IMRT. The PTV coverage was similar, with at least 95% covered for all plans, while the median boost PTV dose differed by 0.1 Gy between the IMRT and VMAT cohorts. The doses to the brain, optic chiasm, optic nerves and eyes were not significantly different. The mean dose to the brainstem, however, was 9.4 Gy less with VMAT (p<0.001). The dose to the ipsilateral and contralateral cochleae were respectively 19.7 and 9.5 Gy less (p<0.001). Conclusion: Comparison of clinical treatment plans for separate IMRT and VMAT cohorts demonstrates that VMAT can save substantial treatment time while providing similar target coverage and superior sparing of the brainstem and cochleae. To our knowledge this is the first study to demonstrate this benefit of VMAT in the management of GBM.« less

  5. Quantitatively Excessive Normal Tissue Toxicity and Poor Target Coverage in Postoperative Lung Cancer Radiotherapy Meta-analysis.

    PubMed

    Abuodeh, Yazan; Naghavi, Arash O; Echevarria, Michelle; DeMarco, MaryLou; Tonner, Brian; Feygelman, Vladimir; Stevens, Craig W; Perez, Bradford A; Dilling, Thomas J

    2018-01-01

    A previous meta-analysis (MA) found postoperative radiotherapy (PORT) in lung cancer patients to be detrimental in N0/N1 patients and equivocal in the N2 setting. We hypothesized that treatment plans generated using MA protocols had worse dosimetric outcomes compared to modern plans. We retrieved plans for 13 patients who received PORT with modern planning. A plan was recreated for each patient using the 8 protocols included in MA. Dosimetric values were then compared between the modern and simulated MA plans. A total of 104 MA plans were generated. Median prescribed dose was 50.4 (range, 50-60) Gy in the modern plans and 53.2 (30-60) Gy in the MA protocols. Median planning volume coverage was 96% (93%-100%) in the modern plans, versus 58% (0%-100%) in the MA plans (P < .001). Internal target volume coverage was 100% (99%-100%) versus 65% (0%-100%), respectively (P < .001). Organs at risk received the following doses: spinal cord maximum dose, 36.8 (4.6-50.4) Gy versus 46.8 (2.9-74.0) Gy (P < .001); esophageal mean dose, 22.9 (5.5-35) Gy versus 30.5 (11.1-52.5) Gy (P = .003); heart V30 (percentage of volume of an organ receiving at least a dose of 30 Gy), 16% (0%-45%) versus 35% (0%-79%) (P = .047); mean lung dose, 12.4 (3.4-24.3) Gy versus 14.8 (4.1-27.4) Gy (P = .008); and lung V20, 18% (4%-34%) versus 25% (8%-67%) (P = .023). We quantitatively confirm the inferiority of the techniques used in the PORT MA. Our analysis showed a lower therapeutic ratio in the MA plans, which may explain the poor outcomes in the MA. The findings of the MA are not relevant in the era of modern treatment planning. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Continuous monitoring and intrafraction target position correction during treatment improves target coverage for patients undergoing SBRT prostate therapy.

    PubMed

    Lovelock, D Michael; Messineo, Alessandra P; Cox, Brett W; Kollmeier, Marisa A; Zelefsky, Michael J

    2015-03-01

    To compare the potential benefits of continuous monitoring of prostate position and intervention (CMI) using 2-mm displacement thresholds during stereotactic body radiation therapy (SBRT) treatment to those of a conventional image-guided procedure involving single localization prior to treatment. Eighty-nine patients accrued to a prostate SBRT dose escalation protocol were implanted with radiofrequency transponder beacons. The planning target volume (PTV) margin was 5 mm in all directions, except for 3 mm in the posterior direction. The prostate was kept within 2 mm of its planned position by the therapists halting dose delivery and, if necessary, correcting the couch position. We computed the number, type, and time required for interventions and where the prostate would have been during dose delivery had there been, instead, a single image-guided setup procedure prior to each treatment. Distributions of prostate displacements were computed as a function of time. After the initial setup, 1.7 interventions per fraction were required, with a concomitant increase in time for dose delivery of approximately 65 seconds. Small systematic drifts in prostate position in the posterior and inferior directions were observed in the study patients. Without CMI, intrafractional motion would have resulted in approximately 10% of patients having a delivered dose that did not meet our clinical coverage requirement, that is, a PTV D95 of >90%. The posterior PTV margin required for 95% of the dose to be delivered with the target positioned within the PTV was computed as a function of time. The margin necessary was found to increase by 2 mm every 5 minutes, starting from the time of the imaging procedure. CMI using a tight 2-mm displacement threshold was not only feasible but was found to deliver superior PTV coverage compared with the conventional image-guided procedure in the SBRT setting. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Continuous Monitoring and Intrafraction Target Position Correction During Treatment Improves Target Coverage for Patients Undergoing SBRT Prostate Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lovelock, D. Michael, E-mail: lovelocm@mskcc.org; Messineo, Alessandra P.; Cox, Brett W.

    2015-03-01

    Purpose: To compare the potential benefits of continuous monitoring of prostate position and intervention (CMI) using 2-mm displacement thresholds during stereotactic body radiation therapy (SBRT) treatment to those of a conventional image-guided procedure involving single localization prior to treatment. Methods and Materials: Eighty-nine patients accrued to a prostate SBRT dose escalation protocol were implanted with radiofrequency transponder beacons. The planning target volume (PTV) margin was 5 mm in all directions, except for 3 mm in the posterior direction. The prostate was kept within 2 mm of its planned position by the therapists halting dose delivery and, if necessary, correcting themore » couch position. We computed the number, type, and time required for interventions and where the prostate would have been during dose delivery had there been, instead, a single image-guided setup procedure prior to each treatment. Distributions of prostate displacements were computed as a function of time. Results: After the initial setup, 1.7 interventions per fraction were required, with a concomitant increase in time for dose delivery of approximately 65 seconds. Small systematic drifts in prostate position in the posterior and inferior directions were observed in the study patients. Without CMI, intrafractional motion would have resulted in approximately 10% of patients having a delivered dose that did not meet our clinical coverage requirement, that is, a PTV D95 of >90%. The posterior PTV margin required for 95% of the dose to be delivered with the target positioned within the PTV was computed as a function of time. The margin necessary was found to increase by 2 mm every 5 minutes, starting from the time of the imaging procedure. Conclusions: CMI using a tight 2-mm displacement threshold was not only feasible but was found to deliver superior PTV coverage compared with the conventional image-guided procedure in the SBRT setting.« less

  8. Relative plan robustness of step-and-shoot vs rotational intensity–modulated radiotherapy on repeat computed tomographic simulation for weight loss in head and neck cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomson, David J.; The University of Manchester, Manchester Academic Health Science Centre, Institute of Cancer Sciences, Manchester; Beasley, William J.

    Introduction: Interfractional anatomical alterations may have a differential effect on the dose delivered by step-and-shoot intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT). The increased degrees of freedom afforded by rotational delivery may increase plan robustness (measured by change in target volume coverage and doses to organs at risk [OARs]). However, this has not been evaluated for head and neck cancer. Materials and methods: A total of 10 patients who required repeat computed tomography (CT) simulation and replanning during head and neck IMRT were included. Step-and-shoot IMRT and VMAT plans were generated from the original planning scan. The initial andmore » second CT simulation scans were fused and targets/OAR contours transferred, reviewed, and modified. The plans were applied to the second CT scan and doses recalculated without repeat optimization. Differences between step-and-shoot IMRT and VMAT for change in target volume coverage and doses to OARs between first and second CT scans were compared by Wilcoxon signed rank test. Results: There were clinically relevant dosimetric changes between the first and the second CT scans for both the techniques (reduction in mean D{sub 95%} for PTV2 and PTV3, D{sub min} for CTV2 and CTV3, and increased mean doses to the parotid glands). However, there were no significant differences between step-and-shoot IMRT and VMAT for change in any target coverage parameter (including D{sub 95%} for PTV2 and PTV3 and D{sub min} for CTV2 and CTV3) or dose to any OARs (including parotid glands) between the first and the second CT scans. Conclusions: For patients with head and neck cancer who required replanning mainly due to weight loss, there were no significant differences in plan robustness between step-and-shoot IMRT and VMAT. This information is useful with increased clinical adoption of VMAT.« less

  9. The new World Health Organization recommendation on the 2-dose measles vaccine schedule and the way forward in African Region

    PubMed Central

    Biellik, Robin Julian; Davis, Robert

    2017-01-01

    The new W.H.O. recommendation, which drops the coverage criterion for adoption of the 2-dose measles vaccine schedule, makes some African countries eligible for the 2-dose schedule which were previously ineligible. We look at the implications of the new recommendation for Ethiopia and Nigeria, the two largest African countries which are eligible under the new recommendation. PMID:29296149

  10. SU-E-T-124: Dosimetric Comparison of HDR Brachytherapy and Intensity Modulated Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, J; Wu, H; Das, I

    2014-06-01

    Purpose: Brachytherapy is known to be able to deliver more radiation dose to tumor while minimizing radiation dose to surrounding normal tissues. Proton therapy also provides superior dose distribution due to Bragg peak. Since both HDR and Intensity Modulated Proton Therapy (IMPT) are beneficial for their quick dose drop off, our goal in this study is to compare the pace of dose gradient drop-off between HDR and IMPT plans based on the same CT image data-set. In addition, normal tissues sparing were also compared among HDR, IMPT and SBRT. Methods: Five cervical cancer cases treated with EBRT + HDR boostmore » combination with Tandem and Ovoid applicator were used for comparison purpose. Original HDR plans with prescribed dose of 5.5 Gy x 5 fractions were generated and optimized. The 100% isodose line of HDR plans was converted to a dose volume, and treated as CTV for IMPT and SBRT planning. The same HDR CT scans were also used for IMPT plan and SBRT plan for direct comparison. The philosophy of the IMPT and SBRT planning was to create the same CTV coverage as HDR plans. All three modalities treatment plans were compared to each other with a set of predetermined criteria. Results: With similar target volume coverage in cervix cancer boost treatment, HDR provides a slightly sharper dose drop-off from 100% to 50% isodose line, averagely in all directions compared to IMPT. However, IMPT demonstrated more dose gradient drop-off at the junction of the target and normal tissues by providing more normal tissue sparing and superior capability to reduce integral dose. Conclusion: IMPT is capable of providing comparable dose drop-off as HDR. IMPT can be explored as replacement for HDR brachytherapy in various applications.« less

  11. SU-E-T-632: Preliminary Study On Treating Nose Skin Using Energy and Intensity Modulated Electron Beams with Monte Carlo Based Dose Calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jin, L; Eldib, A; Li, J

    Purpose: Uneven nose surfaces and air cavities underneath and the use of bolus present complexity and dose uncertainty when using a single electron energy beam to plan treatments of nose skin with a pencil beam-based planning system. This work demonstrates more accurate dose calculation and more optimal planning using energy and intensity modulated electron radiotherapy (MERT) delivered with a pMLC. Methods: An in-house developed Monte Carlo (MC)-based dose calculation/optimization planning system was employed for treatment planning. Phase space data (6, 9, 12 and 15 MeV) were used as an input source for MC dose calculations for the linac. To reducemore » the scatter-caused penumbra, a short SSD (61 cm) was used. Our previous work demonstrates good agreement in percentage depth dose and off-axis dose between calculations and film measurement for various field sizes. A MERT plan was generated for treating the nose skin using a patient geometry and a dose volume histogram (DVH) was obtained. The work also shows the comparison of 2D dose distributions between a clinically used conventional single electron energy plan and the MERT plan. Results: The MERT plan resulted in improved target dose coverage as compared to the conventional plan, which demonstrated a target dose deficit at the field edge. The conventional plan showed higher dose normal tissue irradiation underneath the nose skin while the MERT plan resulted in improved conformity and thus reduces normal tissue dose. Conclusion: This preliminary work illustrates that MC-based MERT planning is a promising technique in treating nose skin, not only providing more accurate dose calculation, but also offering an improved target dose coverage and conformity. In addition, this technique may eliminate the necessity of bolus, which often produces dose delivery uncertainty due to the air gaps that may exist between the bolus and skin.« less

  12. Optimization of Craniospinal Irradiation for Pediatric Medulloblastoma Using VMAT and IMRT.

    PubMed

    Al-Wassia, Rolina K; Ghassal, Noor M; Naga, Adly; Awad, Nesreen A; Bahadur, Yasir A; Constantinescu, Camelia

    2015-10-01

    Intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) provide highly conformal target radiation doses, but also expose large volumes of healthy tissue to low-dose radiation. With improving survival, more children with medulloblastoma (MB) are at risk of late adverse effects of radiotherapy, including secondary cancers. We evaluated the characteristics of IMRT and VMAT craniospinal irradiation treatment plans in children with standard-risk MB to compare radiation dose delivery to target organs and organs at risk (OAR). Each of 10 children with standard-risk MB underwent both IMRT and VMAT treatment planning. Dose calculations used inverse planning optimization with a craniospinal dose of 23.4 Gy followed by a posterior fossa boost to 55.8 Gy. Clinical and planning target volumes were demarcated on axial computed tomography images. Dose distributions to target organs and OAR for each planning technique were measured and compared with published dose-volume toxicity data for pediatric patients. All patients completed treatment planning for both techniques. Analyses and comparisons of dose distributions and dose-volume histograms for the planned target volumes, and dose delivery to the OAR for each technique demonstrated the following: (1) VMAT had a modest, but significantly better, planning target volume-dose coverage and homogeneity compared with IMRT; (2) there were different OAR dose-sparing profiles for IMRT versus VMAT; and (3) neither IMRT nor VMAT demonstrated dose reductions to the published pediatric dose limits for the eyes, the lens, the cochlea, the pituitary, and the brain. The use of both IMRT and VMAT provides good target tissue coverage and sparing of the adjacent tissue for MB. Both techniques resulted in OAR dose delivery within published pediatric dose guidelines, except those mentioned above. Pediatric patients with standard-risk MB remain at risk for late endocrinologic, sensory (auditory and visual), and brain functional impairments.

  13. Evaluating Childhood Vaccination Coverage of NIP Vaccines: Coverage Survey versus Zhejiang Provincial Immunization Information System

    PubMed Central

    Hu, Yu; Chen, Yaping

    2017-01-01

    Vaccination coverage in Zhejiang province, east China, is evaluated through repeated coverage surveys. The Zhejiang provincial immunization information system (ZJIIS) was established in 2004 with links to all immunization clinics. ZJIIS has become an alternative to quickly assess the vaccination coverage. To assess the current completeness and accuracy on the vaccination coverage derived from ZJIIS, we compared the estimates from ZJIIS with the estimates from the most recent provincial coverage survey in 2014, which combined interview data with verified data from ZJIIS. Of the enrolled 2772 children in the 2014 provincial survey, the proportions of children with vaccination cards and registered in ZJIIS were 94.0% and 87.4%, respectively. Coverage estimates from ZJIIS were systematically higher than the corresponding estimates obtained through the survey, with a mean difference of 4.5%. Of the vaccination doses registered in ZJIIS, 16.7% differed from the date recorded in the corresponding vaccination cards. Under-registration in ZJIIS significantly influenced the coverage estimates derived from ZJIIS. Therefore, periodic coverage surveys currently provide more complete and reliable results than the estimates based on ZJIIS alone. However, further improvement of completeness and accuracy of ZJIIS will likely allow more reliable and timely estimates in future. PMID:28696387

  14. Safety and Efficacy of Stereotactic Ablative Radiation Therapy for Renal Cell Carcinoma Extracranial Metastases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Chiachien Jake; Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas; Christie, Alana

    Purpose: Renal cell carcinoma is refractory to conventional radiation therapy but responds to higher doses per fraction. However, the dosimetric data and clinical factors affecting local control (LC) are largely unknown. We aimed to evaluate the safety and efficacy of stereotactic ablative radiation therapy (SAbR) for extracranial renal cell carcinoma metastases. Methods and Materials: We reviewed 175 metastatic lesions from 84 patients treated with SAbR between 2005 and 2015. LC and toxicity after SAbR were assessed with Response Evaluation Criteria in Solid Tumors (RECIST) version 1.1 and Common Terminology Criteria for Adverse Events (CTCAE) version 4.0. Predictors of local failure weremore » analyzed with χ{sup 2}, Kaplan-Meier, and log-rank tests. Results: In most cases (74%), SAbR was delivered with total doses of 40 to 60 Gy, 30 to 54 Gy, and 20 to 40 Gy in 5 fractions, 3 fractions, and a single fraction, respectively. The median biologically effective dose (BED) using the universal survival model was 134.5 Gy. The 1-year LC rate after SAbR was 91.2% (95% confidence interval, 84.9%-95.0%; median follow-up, 16.7 months). Local failures were associated with prior radiation therapy (hazard ratio [HR], 10.49; P<.0001), palliative-intent radiation therapy (HR, 4.63; P=.0189), spinal location (HR, 5.36; P=.0041), previous systemic therapy status (0-1 vs >1; HR, 3.52; P=.0217), and BED <115 Gy (HR, 3.45; P=.0254). Dose received by 99% of the target volume was the strongest dosimetric predictor for LC. Upon multivariate analysis, dose received by 99% of the target volume greater than BED of 98.7 Gy and systemic therapy status remained significant (HR, 0.12 and 3.64, with P=.0014 and P=.0472, respectively). Acute and late grade 3 toxicities attributed to SAbR were observed in 3 patients (1.7%) and 5 patients (2.9%), respectively. Conclusions: SAbR demonstrated excellent LC of metastatic renal cell carcinoma with a favorable safety profile when an adequate dose and coverage were applied. Multimodality treatment with surgery should be considered for reirradiation or vertebral metastasis. A higher radiation dose may be required in patients who received previous systemic therapies.« less

  15. Implementation research: reactive mass vaccination with single-dose oral cholera vaccine, Zambia.

    PubMed

    Poncin, Marc; Zulu, Gideon; Voute, Caroline; Ferreras, Eva; Muleya, Clara Mbwili; Malama, Kennedy; Pezzoli, Lorenzo; Mufunda, Jacob; Robert, Hugues; Uzzeni, Florent; Luquero, Francisco J; Chizema, Elizabeth; Ciglenecki, Iza

    2018-02-01

    To describe the implementation and feasibility of an innovative mass vaccination strategy - based on single-dose oral cholera vaccine - to curb a cholera epidemic in a large urban setting. In April 2016, in the early stages of a cholera outbreak in Lusaka, Zambia, the health ministry collaborated with Médecins Sans Frontières and the World Health Organization in organizing a mass vaccination campaign, based on single-dose oral cholera vaccine. Over a period of 17 days, partners mobilized 1700 health ministry staff and community volunteers for community sensitization, social mobilization and vaccination activities in 10 townships. On each day, doses of vaccine were delivered to vaccination sites and administrative coverage was estimated. Overall, vaccination teams administered 424 100 doses of vaccine to an estimated target population of 578 043, resulting in an estimated administrative coverage of 73.4%. After the campaign, few cholera cases were reported and there was no evidence of the disease spreading within the vaccinated areas. The total cost of the campaign - 2.31 United States dollars (US$) per dose - included the relatively low cost of local delivery - US$ 0.41 per dose. We found that an early and large-scale targeted reactive campaign using a single-dose oral vaccine, organized in response to a cholera epidemic within a large city, to be feasible and appeared effective. While cholera vaccines remain in short supply, the maximization of the number of vaccines in response to a cholera epidemic, by the use of just one dose per member of an at-risk community, should be considered.

  16. How Important Is a Reproducible Breath Hold for Deep Inspiration Breath Hold Breast Radiation Therapy?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiant, David, E-mail: David.wiant@conehealth.com; Wentworth, Stacy; Liu, Han

    Purpose: Deep inspiration breath hold (DIBH) for left-sided breast cancer has been shown to reduce heart dose. Surface imaging helps to ensure accurate breast positioning, but it does not guarantee a reproducible breath hold (BH) at DIBH treatments. We examine the effects of variable BH positions for DIBH treatments. Methods and Materials: Twenty-five patients who underwent free breathing (FB) and DIBH scans were reviewed. Four plans were created for each patient: FB, DIBH, FB-DIBH (the DIBH plans were copied to the FB images and recalculated, and image registration was based on breast tissue), and P-DIBH (a partial BH with themore » heart shifted midway between the FB and DIBH positions). The FB-DIBH plans give a “worst-case” scenario for surface imaging DIBH, where the breast is aligned by surface imaging but the patient is not holding their breath. Kolmogorov-Smirnov tests were used to compare the dose metrics. Results: The DIBH plans gave lower heart dose and comparable breast coverage versus FB in all cases. The FB-DIBH plans showed no significant difference versus FB plans for breast coverage, mean heart dose, or maximum heart dose (P≥.10). The mean heart dose differed between FB-DIBH and FB by <2 Gy for all cases, and the maximum heart dose differed by <2 Gy for 21 cases. The P-DIBH plans showed significantly lower mean heart dose than FB (P<.01). The mean heart doses for the P-DIBH plans were« less

  17. Positioning accuracy and daily dose assessment for prostate cancer treatment using in-room CT image guidance at a proton therapy facility.

    PubMed

    Maeda, Yoshikazu; Sato, Yoshitaka; Minami, Hiroki; Yasukawa, Yutaka; Yamamoto, Kazutaka; Tamamura, Hiroyasu; Shibata, Satoshi; Bou, Sayuri; Sasaki, Makoto; Tameshige, Yuji; Kume, Kyo; Ooto, Hiroshi; Kasahara, Shigeru; Shimizu, Yasuhiro; Saga, Yusuke; Omoya, Akira; Saitou, Makoto

    2018-05-01

    To evaluate the effectiveness of CT image-guided proton radiotherapy for prostate cancer by analyzing the positioning uncertainty and assessing daily dose change due to anatomical variations. Patients with prostate cancer were treated by opposed lateral proton beams based on a passive scattering method using an in-room CT image-guided system. The system employs a single couch for both CT scanning and beam delivery. The patient was positioned by matching the boundary between the prostate and the rectum's anterior region identified in the CT images to the corresponding boundary in the simulator images after bone matching. We acquired orthogonal kV x-ray images after couch movement and confirmed the body position by referring to the bony structure prior to treatment. In offline analyses, we contoured the targeted anatomical structures on 375 sets of daily in-room CT images for 10 patients. The uncertainty of the image-matching procedure was evaluated using the prostate contours and actual couch corrections. We also performed dose calculations using the same set of CT images, and evaluated daily change of dose-volume histograms (DVHs) to compare the effectiveness of the treatment using prostate matching to the bone-matching procedure. The isocenter shifts by prostate matching after bone matching were 0.5 ± 1.8 and -0.8 ± 2.6 mm along the superior-inferior (SI) and anterior-posterior (AP) directions, respectively. The body movement errors (σ) after couch movement were 0.7, 0.5, and 0.3 mm along the lateral, SI and AP direction, respectively, for 30 patients. The estimated errors (σ) in the prostate matching were 1.0 and 1.3 mm, and, in conjunction with the movement errors, the total positioning uncertainty was estimated to be 1.0 and 1.4 mm along the SI and AP directions, respectively. Daily DVH analyses showed that in the prostate matching, 98.7% and 86.1% of the total 375 irradiations maintained a dose condition of V 95%  > 95% for the prostate and a dose constraint of V 77%  < 18% for the rectum, whereas 90.4% and 66.1% of the total irradiations did so when bone matching was used. The dose constraint of the rectum and dose coverage of the prostate were better maintained by prostate matching than bone matching (P < 0.001). The daily variation in the dose to the seminal vesicles (SVs) was large, and only 40% of the total irradiations maintained the initial planned values of V 95% for high-risk treatment. Nevertheless, the deviations from the original value were -4 ± 7% and -5 ± 11% in the prostate and bone matching, respectively, and a better dose coverage of the SV was achieved by the prostate matching. The correction of repositioning along the AP and SI direction from conventional bone matching in CT image-guided proton therapy was found to be effective to maintain the dose constraint of the rectum and the dose coverage of the prostate. This work indicated that prostate cancer treatment by prostate matching using CT image guidance may be effective to reduce the rectal complications and achieve better tumor control of the prostate. However, an adaptive approach is desirable to maintain better dose coverage of the SVs. © 2018 American Association of Physicists in Medicine.

  18. A New Way to Measure the World's Protected Area Coverage

    PubMed Central

    Barr, Lissa M.; Pressey, Robert L.; Fuller, Richard A.; Segan, Daniel B.; McDonald-Madden, Eve; Possingham, Hugh P.

    2011-01-01

    Protected areas are effective at stopping biodiversity loss, but their placement is constrained by the needs of people. Consequently protected areas are often biased toward areas that are unattractive for other human uses. Current reporting metrics that emphasise the total area protected do not account for this bias. To address this problem we propose that the distribution of protected areas be evaluated with an economic metric used to quantify inequality in income— the Gini coefficient. Using a modified version of this measure we discover that 73% of countries have inequitably protected their biodiversity and that common measures of protected area coverage do not adequately reveal this bias. Used in combination with total percentage protection, the Gini coefficient will improve the effectiveness of reporting on the growth of protected area coverage, paving the way for better representation of the world's biodiversity. PMID:21957458

  19. Field trips local and abroad: What every field trip leader needs to know about insurance coverage

    NASA Astrophysics Data System (ADS)

    Jovanelly, T.

    2016-12-01

    Leading field trips locally or internationally is an essential part of being a geoscience educator. Being a field trip guide and coordinator often means that you will be responsible for minors (under the age of 21), transportation, and touring (e.g. hiking, exploring) in unique and sometimes rugged environments. Professors, and alike, at universities and colleges may not have adequate insurance covered should a student(s) render maladies, or worse death, under your advisement. This poster outlines questions that could be presented to your university or college's lawyer to ensure field trip guides are properly covered for liability in most situations. Additionally, it will provide explanation for common legal terms often used when explaining insurance coverage relating to university or college employment. Lastly, this poster will provide suggestions on how to pursue professional coverage polices that can protect you both in the field and in the classroom/laboratory.

  20. Modernizing Medicare's Benefit Design and Low-Income Subsidies to Ensure Access and Affordability.

    PubMed

    Schoen, Cathy; Davis, Karen; Buttorff, Christine; Andersen, Martin

    2015-07-01

    Insurance coverage through the traditional Medicare program is complex, fragmented, and incomplete. Beneficiaries must purchase supplemental private insurance to fill in the gaps. While impoverished beneficiaries may receive supplemental coverage through Medicaid and subsidies for prescription drugs, help is limited for people with incomes above the poverty level. This patchwork quilt leads to confusion for beneficiaries and high administrative costs, while also undermining coverage and care coordination. Most important, Medicare's benefits fail to limit out-of-pocket costs or ensure adequate financial protection, especially for beneficiaries with low incomes and serious health problems. This brief, part of a series about Medicare's past, present, and future, presents options for an integrated benefit for enrollees in traditional Medicare. The new benefit would not only reduce cost burdens but also could potentially strengthen the Medicare program and enhance its role in stimulating and supporting innovations throughout the health care delivery system.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Girigesh, Y; Kumar, L; Raman, K

    Purpose: Aim of this study is to determine the dosimetric influence of Filtered and Flatting Filter Free Photon Beam of 10 MV energy on RA planning for Ca. Cervix. Methods: CT data sets of eleven patients reported with carcinoma cervix were used for RA planning for 10MV -FFB and 10MV-FFFB. RA plans were generated using two full arcs.All RA plans were generated to deliver a dose of 50.4Gy in 28 fractions for PTV and ALARA for OAR’s. All plans were analysed for PTV Coverage, conformity Index, homogeneity index, dose to OAR’s, integral dose to normal tissue and total monitor unitsmore » were studied. Results: DVH was used to evaluate RA plans for both 10MV-FFB and 10MV-FFFB photon beam. Planning results show a comparable PTV coverage for both energies. Results shows volume of PTV receiving prescription dose were 95.10+ 0.09% and 95.09 +0.11%, and volume of PTV receiving a dose of 107% is 0.45+0.96% and 5.25+8.9%, homogeneity index (HI) were 1.051+0.007 and 1.066+0.008, Conformity Index(CI) were 1.003+0.019 and 1.012+0.013, Mean Integral dose were 2.65+0.34 and 2.60+0.33(*10−5Gy.cm3) for 10MV-FFB and 10MV-FFFB respectively. 10MV-FB shows statistically significant (p<0.05) improvement in mean doses to bladder, rectum, bowel and mean total number of MU’s and also shows remarkable decrease in mean total no. of MU’s by 43.7% in comparison to 10MV-FFFB. There is statistically significant (p<0.05) difference found in CI and HI for 10MV-FB in comparison to 10MV -FFF beam. 10MV-FFFB shows statistically significant (p<0.05) for mean NTID and delivers 1.65 % less NTID in comparison to 10 MV- FB. Conclusion: 10MV-FB is superior to 10MV-FFFB for rapid arc planning in case of Cervix carcinomas, it offers better target coverage and OAR’s sparing, comparable mean Integral dose to normal tissues and 10 MV- FB also produced highly conformal and homogeneous dose distribution in comparison to 10MV-FFFB.« less

  2. Estimating human papillomavirus vaccination coverage among young women in Victoria and reasons for non-vaccination.

    PubMed

    Brotherton, Julia M L; Piers, Leonard S; Vaughan, Loretta

    2016-04-01

    Background Adult Australian women aged 18 to 26 years were offered human papillomavirus (HPV) vaccine in a mass catch up campaign between 2007 and 2009. Not all doses administered were notified to Australia's HPV vaccine register and not all young women commenced or completed the vaccine course. We surveyed vaccine age-eligible women as part of the Victorian Population Health Survey 2011-2012, a population based telephone survey, to ascertain self-reported vaccine uptake and reasons for non-vaccination or non-completion of vaccination among young women resident in the state of Victoria, Australia. Among 956 women surveyed, 62.3 per cent (57.8-66.6%) had been vaccinated against HPV and coverage with three doses was estimated at 53.7 per cent (49.1-58.2%). These estimates are higher than register-based estimates for the same cohort, which were 57.8 per cent and 37.2 per cent respectively. A lack of awareness about needing three doses and simply forgetting, rather than fear or experience of side effects, were the most common reasons for failure to complete all three doses. Among women who were not vaccinated, the most frequent reasons were not knowing the vaccine was available, perceiving they were too old to benefit, or not being resident in Australia at the time. It is likely that at least half of Victoria's young women were vaccinated during the catch-up program. This high level of coverage is likely to explain the marked reductions in HPV infection, genital warts and cervical disease already observed in young women in Victoria.

  3. Progress toward measles elimination--Eastern Mediterranean Region, 2008-2012.

    PubMed

    Teleb, Nadia; Lebo, Emmaculate; Ahmed, Hinda; Hossam, Abdel Rahman; El Sayed, El Tayeb; Dabbagh, Alya; Strebel, Peter; Rota, Paul; Alexander, James

    2014-06-13

    In 1997, the 22 countries in the World Health Organization (WHO) Eastern Mediterranean Region (EMR) adopted a goal of measles elimination by 2010. To achieve this goal, the WHO Regional Office for the Eastern Mediterranean Region (EMRO) developed a four-pronged strategy: 1) achieve ≥ 95% vaccination coverage of children with the first dose of measles-containing vaccine (MCV1) in every district of each country through routine immunization services, 2) achieve ≥ 95% vaccination coverage with the second dose of measles-containing vaccine (MCV2) in every district of each country either through a routine 2-dose vaccination schedule or through supplementary immunization activities (SIAs), 3) conduct high-quality, case-based surveillance in all countries, and 4) provide optimal clinical case management, including supplementing diets with vitamin A. Although significant progress was made toward measles elimination in the EMR during 1997-2007, the measles elimination goal was not reached by the target date of 2010, and the date was revised to 2015. This report updates previous reports and summarizes the progress made toward measles elimination in EMR during 2008-2012. From 2008 to 2012, large outbreaks occurred in countries with a high incidence of measles, and reported annual measles cases in EMR increased from 12,186 to 36,456. To achieve measles elimination in EMR, efforts are needed to increase 2-dose vaccination coverage, especially in countries with high incidence of measles and in conflict-affected countries, and to implement innovative strategies to reach populations at high risk in areas with poor access to vaccination services or with civil strife.

  4. Adequacy of Fixed-Dose Heparin Infusions for Venous Thromboembolism Prevention after Microsurgical Procedures.

    PubMed

    Bertolaccini, Corinne M; Prazak, Ann Marie B; Agarwal, Jayant; Goodwin, Isak A; Rockwell, W Bradford; Pannucci, Christopher J

    2018-05-22

     In microvascular surgery, patients often receive unfractionated heparin infusions to minimize risk for microvascular thrombosis. Patients who receive intravenous (IV) heparin are believed to have adequate prophylaxis against venous thromboembolism (VTE). Whether a fixed dose of IV heparin provides detectable levels of anticoagulation, or whether the "one size fits all" approach provides adequate prophylaxis against VTE remains unknown. This study examined the pharmacodynamics of fixed-dose heparin infusions and the effects of real-time, anti-factor Xa (aFXa) level driven heparin dose adjustments.  This prospective clinical trial recruited adult microvascular surgery patients placed on a fixed-dose (500 units/h) unfractionated heparin infusion during their initial microsurgical procedure. Steady-state aFXa levels, a marker of unfractionated heparin efficacy and safety, were monitored. Patients with out-of-range aFXa levels received protocol-driven real-time dose adjustments. Outcomes of interest included aFXa levels in response to heparin 500 units/h, number of dose adjustments required to achieve goal aFXa levels, time to reach goal aFXa level, and 90-day clinically relevant bleeding and VTE.  Twenty patients were recruited prospectively. None of 20 patients had any detectable level of anticoagulation in response to heparin infusions at 500 units/h. The median number of dose adjustments required to reach goal level was five, and median weight-based dose to reach goal level was 11.8 units/kg/h. Real-time dose adjustments significantly increased the proportion of patients with in-range levels (60 vs. 0%, p  = 0.0001). The 90-day VTE rate was 5% and 90-day clinically relevant bleeding rate was 5%.  Fixed-dose heparin infusions at a rate of 500 units/h do not provide a detectable level of anticoagulation after microsurgical procedures and are insufficient for the majority of patients who require VTE prophylaxis. Weight-based heparin infusions at 10 to 12 units/kg/h deserve future study in patients undergoing microsurgical procedures to increase the proportion of patients receiving adequate VTE prophylaxis. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  5. Adolescent vaccination: coverage achieved by ages 13-15 years, and vaccinations received as recommended during ages 11-12 years, National Health Interview Survey 1997-2003.

    PubMed

    McCauley, Mary Mason; Stokley, Shannon; Stevenson, John; Fishbein, Daniel B

    2008-12-01

    To present progress toward Healthy People 2010 vaccination objectives for adolescents aged 13-15 years, and to determine how much catch-up and routine vaccination was administered at the recommended ages of 11-12 years. Data from the 1997-2003 National Health Interview Survey were evaluated. In the first analysis, vaccination coverage levels for adolescents aged 13-15 years were determined for each survey year. Main outcome measures include the percent of adolescents who had received the three-dose hepatitis B vaccine (Hep B) series, the two-dose measles/mumps/rubella vaccine (MMR) series, the tetanus and diphtheria toxoids (Td) booster, and one dose of varicella vaccine. In the second analysis, data from all survey years were combined and vaccination dates were analyzed to determine the percentage of adolescents who were missing any vaccines at ages 11-12 and received them at that age. Data for varicella vaccine were sufficient only for the first analysis. Among the approximately 15%-20% of respondents who reported vaccination history from records in the home and who were reporting on a 13-15-year-old, coverage with three doses of Hep B increased significantly during 1997-2001, from 15.2% to 55.0%. Coverage with MMR and Td fluctuated, with no significant increase; highs were 76.7% for MMR in 2003 and 36.2% for Td in 2002. Examination of vaccination dates for all surveyed adolescents showed that among 11-12-year-olds who needed catch-up vaccine, 0.6%-31.3% were brought up to date for Hep B and 22.1%-31.8% were brought up to date for MMR. For Td, 2.6%-15.4% of 11-12-year-olds who had not previously received Td received the vaccine. Vaccination coverage among adolescents aged 13-15 years was below the Healthy People 2010 goals of 90%, but generally increased over the survey years. However, the suboptimal delivery of needed vaccines during ages 11 and 12 is concerning in light of recent vaccine recommendations targeted at this age. Continuing to focus on strategies to make adolescent preventive care, including vaccination, a new norm is essential.

  6. Methods used for immunization coverage assessment in Canada, a Canadian Immunization Research Network (CIRN) study.

    PubMed

    Wilson, Sarah E; Quach, Susan; MacDonald, Shannon E; Naus, Monika; Deeks, Shelley L; Crowcroft, Natasha S; Mahmud, Salaheddin M; Tran, Dat; Kwong, Jeff; Tu, Karen; Gilbert, Nicolas L; Johnson, Caitlin; Desai, Shalini

    2017-08-03

    Accurate and complete immunization data are necessary to assess vaccine coverage, safety and effectiveness. Across Canada, different methods and data sources are used to assess vaccine coverage, but these have not been systematically described. Our primary objective was to examine and describe the methods used to determine immunization coverage in Canada. The secondary objective was to compare routine infant and childhood coverage estimates derived from the Canadian 2013 Childhood National Immunization Coverage Survey (cNICS) with estimates collected from provinces and territories (P/Ts). We collected information from key informants regarding their provincial, territorial or federal methods for assessing immunization coverage. We also collected P/T coverage estimates for select antigens and birth cohorts to determine absolute differences between these and estimates from cNICS. Twenty-six individuals across 16 public health organizations participated between April and August 2015. Coverage surveys are conducted regularly for toddlers in Quebec and in one health authority in British Columbia. Across P/Ts, different methodologies for measuring coverage are used (e.g., valid doses, grace periods). Most P/Ts, except Ontario, measure up-to-date (UTD) coverage and 4 P/Ts also assess on-time coverage. The degree of concordance between P/T and cNICS coverage estimates varied by jurisdiction, antigen and age group. In addition to differences in the data sources and processes used for coverage assessment, there are also differences between Canadian P/Ts in the methods used for calculating immunization coverage. Comparisons between P/T and cNICS estimates leave remaining questions about the proportion of children fully vaccinated in Canada.

  7. Methods used for immunization coverage assessment in Canada, a Canadian Immunization Research Network (CIRN) study

    PubMed Central

    Quach, Susan; MacDonald, Shannon E.; Naus, Monika; Deeks, Shelley L.; Crowcroft, Natasha S.; Mahmud, Salaheddin M.; Tran, Dat; Kwong, Jeff; Tu, Karen; Johnson, Caitlin; Desai, Shalini

    2017-01-01

    ABSTRACT Accurate and complete immunization data are necessary to assess vaccine coverage, safety and effectiveness. Across Canada, different methods and data sources are used to assess vaccine coverage, but these have not been systematically described. Our primary objective was to examine and describe the methods used to determine immunization coverage in Canada. The secondary objective was to compare routine infant and childhood coverage estimates derived from the Canadian 2013 Childhood National Immunization Coverage Survey (cNICS) with estimates collected from provinces and territories (P/Ts). We collected information from key informants regarding their provincial, territorial or federal methods for assessing immunization coverage. We also collected P/T coverage estimates for select antigens and birth cohorts to determine absolute differences between these and estimates from cNICS. Twenty-six individuals across 16 public health organizations participated between April and August 2015. Coverage surveys are conducted regularly for toddlers in Quebec and in one health authority in British Columbia. Across P/Ts, different methodologies for measuring coverage are used (e.g., valid doses, grace periods). Most P/Ts, except Ontario, measure up-to-date (UTD) coverage and 4 P/Ts also assess on-time coverage. The degree of concordance between P/T and cNICS coverage estimates varied by jurisdiction, antigen and age group. In addition to differences in the data sources and processes used for coverage assessment, there are also differences between Canadian P/Ts in the methods used for calculating immunization coverage. Comparisons between P/T and cNICS estimates leave remaining questions about the proportion of children fully vaccinated in Canada. PMID:28708945

  8. Influence of Population Demography and Immunization History on the Impact of an Antenatal Pertussis Program

    PubMed Central

    Campbell, Patricia Therese; McVernon, Jodie; McIntyre, Peter; Geard, Nicholas

    2016-01-01

    Background. Antenatal pertussis vaccination is being considered as a means to reduce the burden of infant pertussis in low- and middle-income countries (LMICs), but its likely impact in such settings is yet to be quantified. Methods. An individual-based model was used to simulate the demographic structure and dynamics of a population with characteristics similar to those of LMICs. Transmission of pertussis within this population was simulated to capture the incidence of infection in (1) the absence of vaccination; (2) with a primary course only (three doses of diphtheria, tetanus, and pertussis vaccines [DTP3] commencing in 1985, 1995, or 2005 at 20%, 50%, or 80% coverage); and (3) with the addition of an antenatal pertussis program. Results. Modeled annual incidence averaged over the period 2015–2024 reduced with increasing DTP3 coverage, regardless of the year childhood vaccination commenced. Over the same period, the proportion of infants born with passive protection did not change substantially compared with the prevaccination situation, regardless of DTP3 coverage and start year. We found minimal impact of antenatal vaccination on infection in all infants when mothers were eligible for a single antenatal dose. When mothers were eligible for multiple antenatal doses, incidence in infants aged 0–2 months was reduced by around 30%. This result did not hold for the full 0- to 1-year age group, for whom antenatal vaccination did not reduce infection levels. Conclusions. While antenatal vaccination could potentially reduce infant mortality in LMICs, broader gains at the population level are likely to be achieved by focusing efforts on increasing DTP3 coverage. PMID:27838675

  9. Dosimetric Advantages of Midventilation Compared With Internal Target Volume for Radiation Therapy of Pancreatic Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lens, Eelco, E-mail: e.lens@amc.uva.nl; Horst, Astrid van der; Versteijne, Eva

    2015-07-01

    Purpose: The midventilation (midV) approach can be used to take respiratory-induced pancreatic tumor motion into account during radiation therapy. In this study, the dosimetric consequences for organs at risk and tumor coverage of using a midV approach compared with using an internal target volume (ITV) were investigated. Methods and Materials: For each of the 18 patients, 2 treatment plans (25 × 2.0 Gy) were created, 1 using an ITV and 1 using a midV approach. The midV dose distribution was blurred using the respiratory-induced motion from 4-dimensional computed tomography. The resulting planning target volume (PTV) coverage for this blurred dosemore » distribution was analyzed; PTV coverage was required to be at least V{sub 95%} >98%. In addition, the change in PTV size and the changes in V{sub 10Gy}, V{sub 20Gy}, V{sub 30Gy}, V{sub 40Gy}, D{sub mean} and D{sub 2cc} for the stomach and for the duodenum were analyzed; differences were tested for significance using the Wilcoxon signed-rank test. Results: Using a midV approach resulted in sufficient target coverage. A highly significant PTV size reduction of 13.9% (P<.001) was observed. Also, all dose parameters for the stomach and duodenum, except the D{sub 2cc} of the duodenum, improved significantly (P≤.002). Conclusions: By using the midV approach to account for respiratory-induced tumor motion, a significant PTV reduction and significant dose reductions to the stomach and to the duodenum can be achieved when irradiating pancreatic tumors.« less

  10. Informing rubella vaccination strategies in East Java, Indonesia through transmission modelling.

    PubMed

    Wu, Yue; Wood, James; Khandaker, Gulam; Waddington, Claire; Snelling, Thomas

    2016-11-04

    An estimated 110,000 babies are born with congenital rubella syndrome (CRS) worldwide annually; a significant proportion of cases occur in Southeast Asia. Rubella vaccine programs have led to successful control of rubella and CRS, and even the elimination of disease in many countries. However, if vaccination is poorly implemented it might increase the number of women reaching childbearing age who remain susceptible to rubella and thereby paradoxically increase CRS. We used an age-structured transmission model to compare seven alternative vaccine strategies for their impact on reducing CRS disease burden in East Java, a setting which is yet to implement a rubella vaccine program. We also investigated the robustness of model predictions to variation in vaccine coverage and other key epidemiological factors. Without rubella vaccination, approximately 700 babies are estimated to be born with CRS in East Java every year at an incidence of 0.77 per 1000live births. This incidence could be reduced to 0.0045 per 1000 live births associated with 99.9% annual reduction in rubella infections after 20 years if the existing two doses of measles vaccine are substituted with two doses of measles plus rubella combination vaccine with the same coverage (87.8% of 9-month-old infants and 80% of 6-year-old children). By comparison a single dose of rubella vaccine will take longer to reduce the burden of rubella and CRS and will be less robust to lower vaccine coverage. While the findings of this study should be informative for settings similar to East Java, the conclusions are dependent on vaccine coverage which would need consideration before applying to all of Indonesia and elsewhere in Asia. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Progress Toward Measles Elimination - Bangladesh, 2000-2016.

    PubMed

    Khanal, Sudhir; Bohara, Rajendra; Chacko, Stephen; Sharifuzzaman, Mohammad; Shamsuzzaman, Mohammad; Goodson, James L; Dabbagh, Alya; Kretsinger, Katrina; Dhongde, Deepak; Liyanage, Jayantha; Bahl, Sunil; Thapa, Arun

    2017-07-21

    In 2013, at the 66th session of the Regional Committee of the World Health Organization (WHO) South-East Asia Region (SEAR), a regional goal was established to eliminate measles and control rubella and congenital rubella syndrome* by 2020 (1). WHO-recommended measles elimination strategies in SEAR countries include 1) achieving and maintaining ≥95% coverage with 2 doses of measles-containing vaccine (MCV) in every district, delivered through the routine immunization program or through supplementary immunization activities (SIAs) † ; 2) developing and sustaining a sensitive and timely measles case-based surveillance system that meets targets for recommended performance indicators; and 3) developing and maintaining an accredited measles laboratory network (2). In 2014, Bangladesh, one of 11 countries in SEAR, adopted a national goal for measles elimination by 2018 (2,3). This report describes progress and challenges toward measles elimination in Bangladesh during 2000-2016. Estimated coverage with the first MCV dose (MCV1) increased from 74% in 2000 to 94% in 2016. The second MCV dose (MCV2) was introduced in 2012, and MCV2 coverage increased from 35% in 2013 to 93% in 2016. During 2000-2016, approximately 108.9 million children received MCV during three nationwide SIAs conducted in phases. During 2000-2016, reported confirmed measles incidence decreased 82%, from 34.2 to 6.1 per million population. However, in 2016, 56% of districts did not meet the surveillance performance target of ≥2 discarded nonmeasles, nonrubella cases § per 100,000 population. Additional measures that include increasing MCV1 and MCV2 coverage to ≥95% in all districts with additional strategies for hard-to-reach populations, increasing sensitivity of measles case-based surveillance, and ensuring timely transport of specimens to the national laboratory will help achieve measles elimination.

  12. Interactive dose shaping part 2: proof of concept study for six prostate patients

    NASA Astrophysics Data System (ADS)

    Kamerling, Cornelis Ph; Ziegenhein, Peter; Sterzing, Florian; Oelfke, Uwe

    2016-03-01

    Recently we introduced interactive dose shaping (IDS) as a new IMRT planning strategy. This planning concept is based on a hierarchical sequence of local dose modification and recovery operations. The purpose of this work is to provide a feasibility study for the IDS planning strategy based on a small set of six prostate patients. The IDS planning paradigm aims to perform interactive local dose adaptations of an IMRT plan without compromising already established valuable dose features in real-time. Various IDS tools were developed in our in-house treatment planning software Dynaplan and were utilized to create IMRT treatment plans for six patients with an adeno-carcinoma of the prostate. The sequenced IDS treatment plans were compared to conventionally optimized clinically approved plans (9 beams, co-planar). For each patient, several IDS plans were created, with different trade-offs between organ sparing and target coverage. The reference dose distributions were imported into Dynaplan. For each patient, the IDS treatment plan with a similar or better trade-off between target coverage and OAR sparing was selected for plan evaluation, guided by a physician. For this initial study we were able to generate treatment plans for prostate geometries in 15-45 min. Individual local dose adaptations could be performed in less than one second. The average differences compared to the reference plans were for the mean dose: 0.0 Gy (boost) and 1.2 Gy (PTV), for {{D}98%}:-1.1 Gy and for {{D}2%}:1.1 Gy (both target volumes). The dose-volume quality indicators were well below the Quantec constraints. However, we also observed limitations of our currently implemented approach. Most prominent was an increase of the non-tumor integral dose by 16.4% on average, demonstrating that further developments of our planning strategy are required.

  13. Exploratory Study of 4D Versus 3D Robust Optimization in Intensity-Modulated Proton Therapy for Lung Cancer

    PubMed Central

    Liu, Wei; Schild, Steven E.; Chang, Joe Y.; Liao, Zhongxing; Chang, Yu-Hui; Wen, Zhifei; Shen, Jiajian; Stoker, Joshua B.; Ding, Xiaoning; Hu, Yanle; Sahoo, Narayan; Herman, Michael G.; Vargas, Carlos; Keole, Sameer; Wong, William; Bues, Martin

    2015-01-01

    Background To compare the impact of uncertainties and interplay effect on 3D and 4D robustly optimized intensity-modulated proton therapy (IMPT) plans for lung cancer in an exploratory methodology study. Methods IMPT plans were created for 11 non-randomly selected non-small-cell lung cancer (NSCLC) cases: 3D robustly optimized plans on average CTs with internal gross tumor volume density overridden to irradiate internal target volume, and 4D robustly optimized plans on 4D CTs to irradiate clinical target volume (CTV). Regular fractionation (66 Gy[RBE] in 33 fractions) were considered. In 4D optimization, the CTV of individual phases received non-uniform doses to achieve a uniform cumulative dose. The root-mean-square-dose volume histograms (RVH) measured the sensitivity of the dose to uncertainties, and the areas under the RVH curve (AUCs) were used to evaluate plan robustness. Dose evaluation software modeled time-dependent spot delivery to incorporate interplay effect with randomized starting phases of each field per fraction. Dose-volume histogram indices comparing CTV coverage, homogeneity, and normal tissue sparing were evaluated using Wilcoxon signed-rank test. Results 4D robust optimization plans led to smaller AUC for CTV (14.26 vs. 18.61 (p=0.001), better CTV coverage (Gy[RBE]) [D95% CTV: 60.6 vs 55.2 (p=0.001)], and better CTV homogeneity [D5%–D95% CTV: 10.3 vs 17.7 (p=0.002)] in the face of uncertainties. With interplay effect considered, 4D robust optimization produced plans with better target coverage [D95% CTV: 64.5 vs 63.8 (p=0.0068)], comparable target homogeneity, and comparable normal tissue protection. The benefits from 4D robust optimization were most obvious for the 2 typical stage III lung cancer patients. Conclusions Our exploratory methodology study showed that, compared to 3D robust optimization, 4D robust optimization produced significantly more robust and interplay-effect-resistant plans for targets with comparable dose distributions for normal tissues. A further study with a larger and more realistic patient population is warranted to generalize the conclusions. PMID:26725727

  14. Forward treatment planning techniques to reduce the normalization effect in Gamma Knife radiosurgery.

    PubMed

    Cheng, Hao-Wen; Lo, Wei-Lun; Kuo, Chun-Yuan; Su, Yu-Kai; Tsai, Jo-Ting; Lin, Jia-Wei; Wang, Yu-Jen; Pan, David Hung-Chi

    2017-11-01

    In Gamma Knife forward treatment planning, normalization effect may be observed when multiple shots are used for treating large lesions. This effect can reduce the proportion of coverage of high-value isodose lines within targets. The aim of this study was to evaluate the performance of forward treatment planning techniques using the Leksell Gamma Knife for the normalization effect reduction. We adjusted the shot positions and weightings to optimize the dose distribution and reduce the overlap of high-value isodose lines from each shot, thereby mitigating the normalization effect during treatment planning. The new collimation system, Leksell Gamma Knife Perfexion, which contains eight movable sectors, provides an additional means to reduce the normalization effect by using composite shots. We propose different techniques in forward treatment planning that can reduce the normalization effect. Reducing the normalization effect increases the coverage proportion of higher isodose lines within targets, making the high-dose region within targets more uniform and increasing the mean dose to targets. Because of the increase in the mean dose to the target after reducing the normalization effect, we can set the prescribed marginal dose at a higher isodose level and reduce the maximum dose, thereby lowering the risk of complications. © 2017 Shuang Ho Hospital-Taipei Medical University. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  15. Financial considerations insurance and coverage issues in intestinal transplantation.

    PubMed

    Chaney, Michael

    2004-12-01

    To increase healthcare workers' knowledge of reimbursement concerns. Chronological survey of transplants reimbursed at the University of Nebraska Medical Center from December 1997 to October 2003, which include accounts of 30 patients who received intestine transplants. Gross billed hospital charges for the past 30 transplantations ranged from dollars 112094 to dollars 667597. Length of stay ranged from 18 to 119 days. Charges include organ procurement fees. All 30 intestine transplants were reimbursed by third-party healthcare coverage; combination of coverage; and/or patient and family payments, which resulted in adherence to financial guidelines prearranged by the hospital. Financial guidelines are usually cost plus a percentage. Thirteen transplantations occurred after April 2001, when Medicare made a national coverage decision to reimburse this form of transplantation. Since then, obtaining surgical authorization and reimbursement is easier. Most insurance companies and state public health agencies accept intestinal transplantations as a form of treatment. Researching transplant coverage before evaluation is essential to be compensated adequately. Financial guidelines will secure the fiscal success of the program. Educating patients to insurance and entitlements may reduce the out-of-pocket cost to patients. Transplant financial coordinators coordinate these efforts for the facility. The best coverage option for the patient and transplant programs is a combination of commercial healthcare coverage, secondary entitlement program, and fund-raising. With length of stay ranging up to 119 days and a lifetime of posttransplant outpatient follow-up care, it is beneficial for the facility to also have a fundraising program to assist patients.

  16. 20 CFR 722.3 - General criteria; inclusion in and removal from the Secretary's list.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false General criteria; inclusion in and removal... APPROVED STATE LAWS § 722.3 General criteria; inclusion in and removal from the Secretary's list. (a) The... providing adequate coverage for total disability or death due to pneumoconiosis. Each such request shall...

  17. Dosimetric evaluation of high-dose-rate interstitial brachytherapy boost treatments for localized prostate cancer.

    PubMed

    Fröhlich, Georgina; Agoston, Péter; Lövey, József; Somogyi, András; Fodor, János; Polgár, Csaba; Major, Tibor

    2010-07-01

    To quantitatively evaluate the dose distributions of high-dose-rate (HDR) prostate implants regarding target coverage, dose homogeneity, and dose to organs at risk. Treatment plans of 174 implants were evaluated using cumulative dose-volume histograms (DVHs). The planning was based on transrectal ultrasound (US) imaging, and the prescribed dose (100%) was 10 Gy. The tolerance doses to rectum and urethra were 80% and 120%, respectively. Dose-volume parameters for target (V90, V100, V150, V200, D90, D(min)) and quality indices (DNR [dose nonuniformity ratio], DHI [dose homogeneity index], CI [coverage index], COIN [conformal index]) were calculated. Maximum dose in reference points of rectum (D(r)) and urethra (D(u)), dose to volume of 2 cm(3) of the rectum (D(2ccm)), and 0.1 cm(3) and 1% of the urethra (D(0.1ccm) and D1) were determined. Nonparametric correlation analysis was performed between these parameters. The median number of needles was 16, the mean prostate volume (V(p)) was 27.1 cm(3). The mean V90, V100, V150, and V200 were 99%, 97%, 39%, and 13%, respectively. The mean D90 was 109%, and the D(min) was 87%. The mean doses in rectum and urethra reference points were 75% and 119%, respectively. The mean volumetric doses were D(2ccm) = 49% for the rectum, D(0.1ccm) = 126%, and D1 = 140% for the urethra. The mean DNR was 0.37, while the DHI was 0.60. The mean COIN was 0.66. The Spearman rank order correlation coefficients for volume doses to rectum and urethra were R(D(r),D(2ccm)) = 0.69, R(D(u),D0.(1ccm)) = 0.64, R(D(u),D1) = 0.23. US-based treatment plans for HDR prostate implants based on the real positions of catheters provided acceptable dose distributions. In the majority of the cases, the doses to urethra and rectum were kept below the defined tolerance levels. For rectum, the dose in reference points correlated well with dose-volume parameters. For urethra dose characterization, the use of D1 volumetric parameter is recommended.

  18. Primary care practice and health professional determinants of immunisation coverage.

    PubMed

    Grant, Cameron C; Petousis-Harris, Helen; Turner, Nikki; Goodyear-Smith, Felicity; Kerse, Ngaire; Jones, Rhys; York, Deon; Desmond, Natalie; Stewart, Joanna

    2011-08-01

    To identify primary care factors associated with immunisation coverage. A survey during 2005-2006 of a random sample of New Zealand primary care practices, with over-sampling of practices serving indigenous children. An immunisation audit was conducted for children registered at each practice. Practice characteristics and the knowledge and attitudes of doctors, nurses and caregivers were measured. Practice immunisation coverage was defined as the percentage of registered children from 6 weeks to 23 months old at each practice who were fully immunised for age. Associations of practice, doctor, nurse and caregiver factors with practice immunisation coverage were determined using multiple regression analyses. One hundred and twenty-four (61%) of 205 eligible practices were recruited. A median (25th-75th centile) of 71% (57-77%) of registered children at each practice was fully immunised. In multivariate analyses, immunisation coverage was higher at practices with no staff shortages (median practice coverage 76% vs 67%, P = 0.004) and where doctors were confident in their immunisation knowledge (72% vs 67%, P= 0.005). Coverage was lower if the children's parents had received information antenatally, which discouraged immunisation (67% vs 73%, P = 0.008). Coverage decreased as socio-economic deprivation of the registered population increased (P < 0.001) and as the children's age (P = 0.001) and registration age (P = 0.02) increased. CONCLUSIONS Higher immunisation coverage is achieved by practices that establish an early relationship with the family and that are adequately resourced with stable and confident staff. Immunisation promotion should begin antenatally. © 2011 The Authors. Journal of Paediatrics and Child Health © 2011 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  19. Radiographic Underestimation of In Vivo Cup Coverage Provided by Total Hip Arthroplasty for Dysplasia.

    PubMed

    Nie, Yong; Wang, HaoYang; Huang, ZeYu; Shen, Bin; Kraus, Virginia Byers; Zhou, Zongke

    2018-01-01

    The accuracy of using 2-dimensional anteroposterior pelvic radiography to assess acetabular cup coverage among patients with developmental dysplasia of the hip after total hip arthroplasty (THA) remains unclear in retrospective clinical studies. A group of 20 patients with developmental dysplasia of the hip (20 hips) underwent cementless THA. During surgery but after acetabular reconstruction, bone wax was pressed onto the uncovered surface of the acetabular cup. A surface model of the bone wax was generated with 3-dimensional scanning. The percentage of the acetabular cup that was covered by intact host acetabular bone in vivo was calculated with modeling software. Acetabular cup coverage also was determined from a postoperative supine anteroposterior pelvic radiograph. The height of the hip center (distance from the center of the femoral head perpendicular to the inter-teardrop line) also was determined from radiographs. Radiographic cup coverage was a mean of 6.93% (SD, 2.47%) lower than in vivo cup coverage for these 20 patients with developmental dysplasia of the hip (P<.001). However, both methods yielded highly correlated measurements for cup coverage (Pearson r=0.761, P<.001). The size of the acetabular cup (P=.001) but not the position of the hip center (high vs normal) was significantly associated with the difference between radiographic and in vivo cup coverage. Two-dimensional radiographically determined cup coverage conservatively reflects in vivo cup coverage and remains an important index (taking 7% underestimation errors and the effect of greater underestimation of larger cup size into account) for assessing the stability of the cup and monitoring for adequate ingrowth of bone. [Orthopedics. 2018; 41(1):e46-e51.]. Copyright 2017, SLACK Incorporated.

  20. TH-A-19A-06: Site-Specific Comparison of Analytical and Monte Carlo Based Dose Calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schuemann, J; Grassberger, C; Paganetti, H

    2014-06-15

    Purpose: To investigate the impact of complex patient geometries on the capability of analytical dose calculation algorithms to accurately predict dose distributions and to verify currently used uncertainty margins in proton therapy. Methods: Dose distributions predicted by an analytical pencilbeam algorithm were compared with Monte Carlo simulations (MCS) using TOPAS. 79 complete patient treatment plans were investigated for 7 disease sites (liver, prostate, breast, medulloblastoma spine and whole brain, lung and head and neck). A total of 508 individual passively scattered treatment fields were analyzed for field specific properties. Comparisons based on target coverage indices (EUD, D95, D90 and D50)more » were performed. Range differences were estimated for the distal position of the 90% dose level (R90) and the 50% dose level (R50). Two-dimensional distal dose surfaces were calculated and the root mean square differences (RMSD), average range difference (ARD) and average distal dose degradation (ADD), the distance between the distal position of the 80% and 20% dose levels (R80- R20), were analyzed. Results: We found target coverage indices calculated by TOPAS to generally be around 1–2% lower than predicted by the analytical algorithm. Differences in R90 predicted by TOPAS and the planning system can be larger than currently applied range margins in proton therapy for small regions distal to the target volume. We estimate new site-specific range margins (R90) for analytical dose calculations considering total range uncertainties and uncertainties from dose calculation alone based on the RMSD. Our results demonstrate that a reduction of currently used uncertainty margins is feasible for liver, prostate and whole brain fields even without introducing MC dose calculations. Conclusion: Analytical dose calculation algorithms predict dose distributions within clinical limits for more homogeneous patients sites (liver, prostate, whole brain). However, we recommend treatment plan verification using Monte Carlo simulations for patients with complex geometries.« less

Top