Science.gov

Sample records for adhesive tape samples

  1. Selection of an adhesive tape suitable for forensic fiber sampling.

    PubMed

    De Wael, Kris; Gason, Fabrice G C S J; Baes, Christiaan A V

    2008-01-01

    Five commercial adhesive tapes were tested for fiber uptake and saturation, for recovery and for ease of analysis. On the basis of the results, a high tack adhesive tape has been selected to be used for forensic fiber sampling. This adhesive tape is used as sampling material in two different micro trace kits. The first tape lifting kit is used mainly for the sampling of cars and the second is a 1:1 tape lifting kit for the collection of fibers on a corpse.

  2. Non-destructive sampling of rock-dwelling microbial communities using sterile adhesive tape.

    PubMed

    Cutler, Nick A; Oliver, Anna E; Viles, Heather A; Whiteley, Andrew S

    2012-12-01

    Building stone provides a habitat for an array of microorganisms, many of which have been demonstrated to have a deleterious effect on the appearance and/or structural integrity of stone masonry. It is essential to understand the composition and structure of stone-dwelling (lithobiontic) microbial communities if successful stone conservation strategies are to be applied, particularly in the face of global environmental change. Ideally, the techniques used to sample such assemblages should be non-destructive due to the sensitive conservation status of many stone buildings. This paper quantitatively assesses the performance of sterile adhesive tape as a non-destructive sampling technique and compares the results of tape sampling with an alternative, destructive, sampling method. We used DNA fingerprinting (TRFLP) to characterise the algal, fungal and bacterial communities living on a stone slab. Our results demonstrate that tape sampling may be used to collect viable quantities of microbial DNA from environmental samples. This technique is ideally suited to the sampling of microbial biofilms, particularly when these communities are dominated by green algae. It provides a good approximation of total community diversity (i.e. the aggregate diversity of epilithic and endolithic communities). Tape sampling is straightforward, rapid and cost effective. When combined with molecular analytical techniques, this sampling method has the potential to make a major contribution to efforts to understand the structure of lithobiontic microbial communities and our ability to predict the response of such communities to future environmental change.

  3. Tape-Smoothing Tool For Adhesion Tests

    NASA Technical Reports Server (NTRS)

    Allen, Peter B.

    1992-01-01

    Small tool smoothes adhesive tape uniformly to ensure consistency and repeatability of tape-peel tests of adhesion of paint to substrate. Includes resilient pad covered with tough, smooth fabric. Internal spring regulates force applied to tape.

  4. Applicability of DNA analysis on adhesive tape in forensic casework.

    PubMed

    Zech, Wolf-Dieter; Malik, Naseem; Thali, Michael

    2012-07-01

    Adhesive tape is commonly used in crimes and is often the subject of forensic evaluation. DNA analysis of adhesive tape can provide DNA profiles of suspects. The object of this study was to evaluate the applicability of DNA analysis on adhesive tape samples in forensic casework. We retrospectively reviewed all cases involving adhesive tape or similar items received by our institute for DNA analysis during the past 11 years. From 100 forensic cases reviewed, 150 adhesive tape samples were examined. A total of 98 DNA profiles were obtained from these samples. Sixty-two of the profiles provided feasible case-relevant information. In conclusion, DNA profiling of adhesive tape samples can be useful in a variety of forensic cases.

  5. Transfer of adhesive tape between calender rolls

    NASA Astrophysics Data System (ADS)

    Johnson, K. L.; Kauzlarich, J. J.

    2004-03-01

    In the calendering process a tape or sheet of deformable material passes through the nip between hard cylindrical rollers. Usually the rolls are driven at the same peripheral speed, but small differences in speed, often referred to as 'creep', can occur if one of the rolls is externally driven and the other is driven by the friction in the contact. In these circumstances it has been observed that a tape that enters the nip adhering to the driven (slower) surface may transfer at exit to the driving (faster) surface but not the other way round. The mechanics of this transfer process is examined theoretically and experimentally in this paper for the case of double sided adhesive tape. It is argued that on emerging from the nip the tape will separate from the surface at which the shear strain in the adhesive is greater and that for transfer to occur the contact load must be sufficient to cause plastic extension of the tape.

  6. Light-Curing Adhesive Repair Tapes

    NASA Technical Reports Server (NTRS)

    Allred, Ronald; Haight, Andrea Hoyt

    2009-01-01

    Adhesive tapes, the adhesive resins of which can be cured (and thereby rigidized) by exposure to ultraviolet and/or visible light, are being developed as repair patch materials. The tapes, including their resin components, consist entirely of solid, low-outgassing, nonhazardous or minimally hazardous materials. They can be used in air or in vacuum and can be cured rapidly, even at temperatures as low as -20 C. Although these tapes were originally intended for use in repairing structures in outer space, they can also be used on Earth for quickly repairing a wide variety of structures. They can be expected to be especially useful in situations in which it is necessary to rigidize tapes after wrapping them around or pressing them onto the parts to be repaired.

  7. High-throughput DNA extraction of forensic adhesive tapes.

    PubMed

    Forsberg, Christina; Jansson, Linda; Ansell, Ricky; Hedman, Johannes

    2016-09-01

    Tape-lifting has since its introduction in the early 2000's become a well-established sampling method in forensic DNA analysis. Sampling is quick and straightforward while the following DNA extraction is more challenging due to the "stickiness", rigidity and size of the tape. We have developed, validated and implemented a simple and efficient direct lysis DNA extraction protocol for adhesive tapes that requires limited manual labour. The method uses Chelex beads and is applied with SceneSafe FAST tape. This direct lysis protocol provided higher mean DNA yields than PrepFiler Express BTA on Automate Express, although the differences were not significant when using clothes worn in a controlled fashion as reference material (p=0.13 and p=0.34 for T-shirts and button-down shirts, respectively). Through in-house validation we show that the method is fit-for-purpose for application in casework, as it provides high DNA yields and amplifiability, as well as good reproducibility and DNA extract stability. After implementation in casework, the proportion of extracts with DNA concentrations above 0.01ng/μL increased from 71% to 76%. Apart from providing higher DNA yields compared with the previous method, the introduction of the developed direct lysis protocol also reduced the amount of manual labour by half and doubled the potential throughput for tapes at the laboratory. Generally, simplified manual protocols can serve as a cost-effective alternative to sophisticated automation solutions when the aim is to enable high-throughput DNA extraction of complex crime scene samples.

  8. Application of infrared spectroscopy and pyrolysis gas chromatography for characterisation of adhesive tapes

    NASA Astrophysics Data System (ADS)

    Zięba-Palus, Janina; Nowińska, Sabina; Kowalski, Rafał

    2016-12-01

    Infrared spectroscopy and pyrolysis GC/MS were applied in the comparative analysis of adhesive tapes. By providing information about the polymer composition, it was possible to classify both backings and adhesives of tapes into defined chemical classes. It was found that samples of the same type (of backings and adhesives) and similar infrared spectra can in most cases be effectively differentiated using Py-GC/MS, sometimes based only on the presence of peaks of very low intensity originating from minor components. The results obtained enabled us to draw the conclusion that Py-GC/MS appears to be a valuable analytical technique for examining tapes, which is complementary to infrared spectroscopy. Identification of pyrolysis products enables discrimination of samples. Both methods also provide crucial information that is useful for identification of adhesive tapes found at the crime scene.

  9. Adhesive Tape and Intravascular-Catheter-Associated Infections

    PubMed Central

    Redelmeier, Donald A; Livesley, Nigel J

    1999-01-01

    Adhesive tape is placed in close contact with intravascular catheters for extended periods and could theoretically contribute to local infections. We found that 74% of specimens of tape collected in one hospital were colonized by pathogenic bacteria. However, only 5% of specimens had significant growth from an inner layer obtained by discarding the outside layer from each roll. We suggest that adhesive tape is a potential source of pathogenic bacteria and that discarding the outer layer from a partially used roll might be a simple method for reducing the risk of infection to patients. PMID:10354258

  10. The use of adhesive tape for recovery of DNA from crime scene items.

    PubMed

    Barash, Mark; Reshef, Ayeleth; Brauner, Paul

    2010-07-01

    The selection of the appropriate method of collection of biological material from crime scene items can be crucial to obtaining a DNA profile. The three techniques commonly used for sampling items are: cutting, swabbing, and taping. The tape sampling technique offers an advantage, in that it enables the collection of a potentially highly informative source of DNA, shed epithelial cells, from selected areas on crime scene items (the inside fingers of a glove, for instance). Furthermore, surface collection of biological material by taping reduces co-sampling of known PCR inhibitors such as clothing dyes. The correct choice of tape for crime scene item sampling is important. Not all tapes are suitable for biological trace evidence collection as well as DNA extraction. We report on one tape that met both these criteria. Three different cases are presented which demonstrate the usefulness of adhesive tape sampling of crime items. Finally, the advantages of the tape collection technique are discussed and guidelines for preferred areas of tape sampling on various casework items are presented.

  11. Leprosy wound healing with ordinary adhesive tape. A preliminary report.

    PubMed

    Stenström, S; Hallmans, G; De Jongh, A; De Wael, T

    1976-01-01

    The use of adhesive tape as wound treatment in leprosy cases is described and found to be superior to the classical dressing as regards security and facility of application, and for the rapidity and quality of healing. Its use as a "preventive" treatment is stressed. The results of this study seem to justify the following conclusions: The adhesive tape is easy to handle, it heals the leprosy wounds in about half the time necessary for the classical dressing and it costs about 50 times less.

  12. 21 CFR 878.4730 - Surgical skin degreaser or adhesive tape solvent.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical skin degreaser or adhesive tape solvent... Surgical skin degreaser or adhesive tape solvent. (a) Identification. A surgical skin degreaser or an... dissolve surface skin oil or adhesive tape. (b) Classification. Class I (general controls). The device...

  13. 21 CFR 878.4730 - Surgical skin degreaser or adhesive tape solvent.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Surgical skin degreaser or adhesive tape solvent... Surgical skin degreaser or adhesive tape solvent. (a) Identification. A surgical skin degreaser or an... dissolve surface skin oil or adhesive tape. (b) Classification. Class I (general controls). The device...

  14. 21 CFR 878.4730 - Surgical skin degreaser or adhesive tape solvent.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Surgical skin degreaser or adhesive tape solvent... Surgical skin degreaser or adhesive tape solvent. (a) Identification. A surgical skin degreaser or an... dissolve surface skin oil or adhesive tape. (b) Classification. Class I (general controls). The device...

  15. 21 CFR 878.4730 - Surgical skin degreaser or adhesive tape solvent.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Surgical skin degreaser or adhesive tape solvent... Surgical skin degreaser or adhesive tape solvent. (a) Identification. A surgical skin degreaser or an... dissolve surface skin oil or adhesive tape. (b) Classification. Class I (general controls). The device...

  16. 21 CFR 878.4730 - Surgical skin degreaser or adhesive tape solvent.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Surgical skin degreaser or adhesive tape solvent... Surgical skin degreaser or adhesive tape solvent. (a) Identification. A surgical skin degreaser or an... dissolve surface skin oil or adhesive tape. (b) Classification. Class I (general controls). The device...

  17. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification... together the skin edges of a wound, to support an injured part of the body, or to secure objects to the skin. (b) Classification. Class I (general controls). The device is exempt from the...

  18. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification... together the skin edges of a wound, to support an injured part of the body, or to secure objects to the skin. (b) Classification. Class I (general controls). The device is exempt from the...

  19. Analysis of particulates on tape lift samples

    NASA Astrophysics Data System (ADS)

    Moision, Robert M.; Chaney, John A.; Panetta, Chris J.; Liu, De-Ling

    2014-09-01

    Particle counts on tape lift samples taken from a hardware surface exceeded threshold requirements in six successive tests despite repeated cleaning of the surface. Subsequent analysis of the particle size distributions of the failed tests revealed that the handling and processing of the tape lift samples may have played a role in the test failures. In order to explore plausible causes for the observed size distribution anomalies, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) were employed to perform chemical analysis on collected particulates. SEM/EDX identified Na and S containing particles on the hardware samples in a size range identified as being responsible for the test failures. ToF-SIMS was employed to further examine the Na and S containing particulates and identified the molecular signature of sodium alkylbenzene sulfonates, a common surfactant used in industrial detergent. The root cause investigation suggests that the tape lift test failures originated from detergent residue left behind on the glass slides used to mount and transport the tape following sampling and not from the hardware surface.

  20. Characterization of Tape Adhesion to Chemical Agent Resistant Coatings

    DTIC Science & Technology

    2015-01-01

    mitigating properties into CARC systems currently in use. The performance of these coatings is evaluated using MIL -DTL-530721. During the coating...application phase and in the field, a tape pull off test is required by MIL -DTL-53072 to gauge adhesive strength of a coating to a primer or substrate...properties into CARC systems currently in use. The performance of these coatings is evaluated using MIL -DTL-53072 1 . During the coating application phase

  1. High Fidelity Tape Transfer Printing Based On Chemically Induced Adhesive Strength Modulation

    PubMed Central

    Sim, Kyoseung; Chen, Song; Li, Yuhang; Kammoun, Mejdi; Peng, Yun; Xu, Minwei; Gao, Yang; Song, Jizhou; Zhang, Yingchun; Ardebili, Haleh; Yu, Cunjiang

    2015-01-01

    Transfer printing, a two-step process (i.e. picking up and printing) for heterogeneous integration, has been widely exploited for the fabrication of functional electronics system. To ensure a reliable process, strong adhesion for picking up and weak or no adhesion for printing are required. However, it is challenging to meet the requirements of switchable stamp adhesion. Here we introduce a simple, high fidelity process, namely tape transfer printing(TTP), enabled by chemically induced dramatic modulation in tape adhesive strength. We describe the working mechanism of the adhesion modulation that governs this process and demonstrate the method by high fidelity tape transfer printing several types of materials and devices, including Si pellets arrays, photodetector arrays, and electromyography (EMG) sensors, from their preparation substrates to various alien substrates. High fidelity tape transfer printing of components onto curvilinear surfaces is also illustrated. PMID:26553110

  2. High Fidelity Tape Transfer Printing Based On Chemically Induced Adhesive Strength Modulation

    NASA Astrophysics Data System (ADS)

    Sim, Kyoseung; Chen, Song; Li, Yuhang; Kammoun, Mejdi; Peng, Yun; Xu, Minwei; Gao, Yang; Song, Jizhou; Zhang, Yingchun; Ardebili, Haleh; Yu, Cunjiang

    2015-11-01

    Transfer printing, a two-step process (i.e. picking up and printing) for heterogeneous integration, has been widely exploited for the fabrication of functional electronics system. To ensure a reliable process, strong adhesion for picking up and weak or no adhesion for printing are required. However, it is challenging to meet the requirements of switchable stamp adhesion. Here we introduce a simple, high fidelity process, namely tape transfer printing(TTP), enabled by chemically induced dramatic modulation in tape adhesive strength. We describe the working mechanism of the adhesion modulation that governs this process and demonstrate the method by high fidelity tape transfer printing several types of materials and devices, including Si pellets arrays, photodetector arrays, and electromyography (EMG) sensors, from their preparation substrates to various alien substrates. High fidelity tape transfer printing of components onto curvilinear surfaces is also illustrated.

  3. New developments for the investigation of hard X-rays emitted by peeling adhesive tapes.

    PubMed

    Krämer, D; Lützenkirchen-Hecht, D; Lühmann, B; Keite-Telgenbüscher, K; Frahm, R

    2013-05-01

    We realized an advanced apparatus for the investigation of emitted X-rays produced by peeling adhesive tape rolls under vacuum conditions. Two stepper motors can unwind and rewind a tape roll, and an additional roller with an optical encoder provides measurement and control of the tape speed. This way reproducible and consecutive experiments are feasible without having to change the tape or break the vacuum. The dependence of the X-ray emission on tape speed, gas pressure, type of adhesive tape, and detector angle has been investigated. The resulting spectra are continuous and span an X-ray energy range of typically 2-60 keV with high intensity. Furthermore, the new apparatus allows the in situ metalization of adhesive tape rolls by a gold sputter source. A significantly increased X-ray emission was observed for adhesive tapes with a metal coating. Thin metal foils have been placed between the tape and the detector, different K- and L-absorption edges could be measured. A considerable enhancement of the emission was achieved under the influence of the magnetic field of an NdFeB permanent magnet.

  4. Endotracheal tube fixation methods for optimal stability: a comparison of adhesive tape, suture, and tape-suture fixation.

    PubMed

    Farbod, Frank; Tuli, Puneet; Robertson, Bernard F; Jackson, Ian T

    2010-07-01

    Accidental extubation of an intubated patient is a serious consideration in the surgical patient. Adequate fixation in the intubated patient is essential to prevent potentially life-threatening complications. Several methods of endotracheal tube fixation have been described in the literature. In this study, we examine 3 common methods of fixation: adhesive tape alone, suture, and tape-suture. Testing occurred in a laboratory setting with 2 fresh cadavers. Endotracheal tubes were inserted, using the methods of fixation in question. We subjected each fixation technique to progressively increasing weight to determine which technique is most resistant to accidental removal. We found that fixation of the tube by combining tape around the tube with a suture through the tape is the best noninvasive technique of the 3 methods evaluated in cases where movement of the head is anticipated.

  5. Securing the endotracheal tube with adhesive tape: an integrative literature review.

    PubMed

    Krug, Lois; Machan, Melissa; Villalba, Jose

    2014-12-01

    The practice of securing the endotracheal tube with adhesive tape appears to be benign. However, evidence-based research suggests it is a high-risk practice. Common elements for the taping practice include the tape, anesthesia gas machine, and anesthesia provider. Researchers have found that adhesive tape outside its original packaging became contaminated with pathogens. The bacteria found on the tape included Pseudomonas, Escherichia coli, Klebsiella, Enterobacter, coagulase-positive staphylococci, methicillin-resistant Staphylococcus aureus and vancomycin-resistant enterococcal organisms. In addition, a patient does not need to have direct contact with the anesthesia gas machine for pathogen transmission to occur. Anesthesia providers were identified as the origin of bacterial transmission in 12% of cases, with pathogens on their hands 66% of the time. Unfortunately, anesthesia providers are often noncompliant with hand hygiene. They failed to practice hand hygiene 82% of the time. Last, the tape can drop to the floor and harbor pathogens despite cleaning 41.6% of the time; it is often retrieved and reused. All the common elements, independently and collectively, involve the tape and its potential to increase the patient's exposure to pathogens and the risk of infection. This literature review presents evidence-based research regarding endotracheal tube taping practice to ensure patient safety.

  6. Autopsy reenactment--a useful technique in the evaluation of adhesive tape asphyxia.

    PubMed

    Herbst, Jonathon; Stanley, Wayne; Byard, Roger W

    2014-05-01

    A 19-year-old woman was found dead with her face and head wrapped in plastic adhesive tape in a cupboard beside an opened helium cylinder. Despite the alleged presence of a suicide message on a social networking website, the unusual circumstances raised the possibility at the time of autopsy of either accidental death from sexual asphyxia or homicide. A carefully monitored reenactment demonstrated, however, that the type of commercial adhesive tape that had been used did not cause complete airway obstruction and that it was possible to wrap a considerable length of tape around the head and neck with the breath held. All of the features at autopsy were, therefore, compatible with self-infliction. Asphyxial death was attributed to the combined effects of smothering from tape and anoxia from helium, an extremely rare combination in young females.

  7. Characterizing acrylic pressure-sensitive adhesive tapes favoring diverse biomedical applications

    NASA Astrophysics Data System (ADS)

    Alhijji, Saleh Mohammed S.

    Strong, self-adhesive acrylic polymer-based tapes have been identified as FDA-approved medical device construction components that might also serve in diverse biological locations as artificial muscles, ligaments, or compressive support discs. After assuring that the tapes themselves were not cytotoxic, they were evaluated as possible low-tension muscle substitutes for eyelids, jaws, and other modest body re-closing needs, and well as for higher-tension applications as artificial ligaments. Self-adhesion of the tapes to representative biomaterials, before and after radio-frequency glow discharge treatment for surface energy modification, illustrated the conditions for maximum attachment strength to nonphysiologic substances. Attachment to bony host parts was challenging but apparently met by the application of acrylic-composite-to-dentin bonding systems that has shown good long-term experience in the mouth. Above all, the compression-relaxation properties of the tape materials were superior and their uses in potential Nucleus Pulposus applications for spinal disc repair were most completely explored. Tests included tape-disc performance longevity, both dry and wet, for over 5000 load-relaxation cycles, with no apparent changes in results for the most dense of the tapes evaluated. Direct abrasion was avoided by insertion of rigid polymeric layers. It is recommended that the compressive loading properties of acrylic tapes be further evaluated for spine repair applications.

  8. A test rig for analysis of adhesive tapes at 4 K cryogenic temperature

    NASA Astrophysics Data System (ADS)

    Funke, Thomas; Germer, Alexander; Haberstroh, Christoph; Mayrhofer, Robert; Stipsitz, Johannes

    2017-02-01

    Cryostats and dewar vessels, in particular those used for liquid helium applications, are usually equipped with multi-layer insulation (MLI). Thereby, multiple foils are wrapped around the respective vessels, tubing and components. As standard, different foils are bonded edge to edge using adhesive tapes either based on aluminized non-metallic films or on aluminum foil. There are a number of standard test procedures for adhesive tapes near ambient temperatures (e.g. AFERA 5012/ISO 29863) allowing a standardized characterization of tapes in terms of holding force and long-term reliability. Unfortunately this does not hold true for adhesive tapes to be used at cryogenic temperatures. In this respect, a test rig comprised of a spring-based traction mechanism has been developed by the authors. Combined with a liquid helium dewar, the fabricated test set-up allows a precise and reproducible application of an adjustable tensile load at 4.2 K and measurements of the respective holding time. In the following, the overall set-up including its significant features is described and first experimental results with aluminum tapes are presented.

  9. Frog tongue acts as muscle-powered adhesive tape

    PubMed Central

    Kleinteich, Thomas; Gorb, Stanislav N.

    2015-01-01

    Frogs are well known to capture fast-moving prey by flicking their sticky tongues out of the mouth. This tongue projection behaviour happens extremely fast which makes frog tongues a biological high-speed adhesive system. The processes at the interface between tongue and prey, and thus the mechanism of adhesion, however, are completely unknown. Here, we captured the contact mechanics of frog tongues by filming tongue adhesion at 2000 frames per second through an illuminated glass. We found that the tongue rolls over the target during attachment. However, during the pulling phase, the tongue retractor muscle acts perpendicular to the target surface and thus prevents peeling during tongue retraction. When the tongue detaches, mucus fibrils form between the tongue and the target. Fibrils commonly occur in pressure-sensitive adhesives, and thus frog tongues might be a biological analogue to these engineered materials. The fibrils in frog tongues are related to the presence of microscopic papillae on the surface. Together with a layer of nanoscale fibres underneath the tongue epithelium, these surface papillae will make the tongue adaptable to asperities. For the first time, to the best of our knowledge, we are able to integrate anatomy and function to explain the processes during adhesion in frog tongues. PMID:26473054

  10. Environmental Research Brief: Pollution prevention assessment for a Manufacturer of pressure-sensitive adhesive tape

    SciTech Connect

    Edwards, H.W.; Kostrzewa, M.F.; Looby, G.P.

    1995-08-01

    The Waste Minimization Assessment Center at Colorado State University performed an assessment at a plant that manufactures three varieties of pressure-sensitive tape. The team report indicated that waste natural rubber adhesive is shipped offsite for disposal in large quantities, and that singificant cost savings could be achieved by redesigning the adhesive applicator on the coater for natural rubber adhesive. This research brief discusses the manufacturing process, existing waste management practices, pollution prevention opportunities, and gives additional recommendations. Tables summarize current waste generation and recommended pollution prevention opportunity.

  11. Using hydrophilic adhesive tape for collection of evidence for forensic DNA analysis.

    PubMed

    Li, Richard C; Harris, Howard A

    2003-11-01

    Known exemplar samples of human DNA have traditionally been body fluids, such as blood, saliva, and semen. In each case, the presence of water is a risk for the bacterial growth, which may degrade the DNA evidence. In this study, the authors have developed a method that employed a hydrophilic adhesive tape (HAT) for collecting DNA evidence. The HAT method was used to remove surface cells from relatively hairless areas on the body. The area examined were ankle, arm, behind the ear, between fingers and back of the neck. The HAT was then dissolved in the extraction buffer. DNA typing was performed at vWA, THo1, F13A1, and FES loci using the short tandem repeat (STR) analysis. Our results show that the samples collected from ear give the best results with a success rate of 100%. All subjects tested by this method had known STR genotypes established from buccal swabs. The authors' results suggest that the HAT method can be used as a less invasive method for collecting biological evidence for forensic DNA analysis. In addition, this collection method should reduce the risk of DNA degradation due to the moisture, which is encountered using conventional collecting methods.

  12. Degradation of the Adhesive Properties of MD-944 Diode Tape by Simulated Low Earth Orbit Environmental Factors

    NASA Technical Reports Server (NTRS)

    Albyn, K.; Finckenor, M.

    2006-01-01

    The International Space Station (ISS) solar arrays utilize MD-944 diode tape with silicone pressure-sensitive adhesive to protect the underlying diodes and also provide a high-emittance surface. On-orbit, the silicone adhesive will be exposed and ultimately convert to a glass-like silicate due to atomic oxygen (AO). The current operational plan is to retract ISS solar array P6 and leave it stored under load for a long duration (6 mo or more). The exposed silicone adhesive must not cause the solar array to stick to itself or cause the solar array to fail during redeployment. The Environmental Effects Branch at Marshall Space Flight Center, under direction from the ISS Program Office Environments Team, performed simulated space environment exposures with 5-eV AO, near ultraviolet radiation and ionizing radiation. The exposed diode tape samples were put under preload and then the resulting blocking force was measured using a tensile test machine. Test results indicate that high-energy AO, ultraviolet radiation, and electron ionizing radiation exposure all reduce the blocking force for a silicone-to-silicone bond. AO exposure produces the most significant reduction in blocking force

  13. A novel method to fabricate parylene-based flexible microfluidic platforms with commercial adhesive tape

    NASA Astrophysics Data System (ADS)

    Kim, Byung Jun; Lee, Donghee; Lee, Jongho; Yang, Sung

    2015-01-01

    We developed a new method to fabricate parylene-based flexible microfluidic platforms using commercial adhesive tape. Most of the previous methods required the preparation of parylene channels via a parylene-to-parylene bonding, which could only be achieved at high pressure and temperature. Instead, our method exploits the adherent property of commercial tape as a substrate for the parylene peel-off process. Once the parylene thin film is deposited by chemical vapour deposition (CVD) on top of the polydimethylsiloxane (PDMS) replica, prepared by conventional lithography process, an adhesive tape peels off the deposited parylene layer with the micro-scale structures from the PDMS replica. We found that the minimum size of the circle posts successfully fabricated by this process is about 10 μm in diameter and 10 μm in height; the maximum value in aspect ratio is about 2.5. In our experimental investigation, pressure in the parylene channels with different wall thicknesses, was measured to estimate the hydraulic resistance of the channel. Our results are comparable with calculated data, with a normalized deviation smaller than 5%. In addition, the hydraulic resistance of the channels on the curved surface obtained with a similar approach showed an increase when the radius of curvature was reduced. Finally, this contribution shows that our method enables a simple and relatively inexpensive fabrication of flexible microfluidic platforms.

  14. Missing physics in stick-slip dynamics of a model for peeling of an adhesive tape.

    PubMed

    De, Rumi; Ananthakrishna, G

    2005-05-01

    It is now known that the equations of motion for the contact point during peeling of an adhesive tape mounted on a roll introduced earlier are singular and do not support dynamical jumps across the two stable branches of the peel force function. By including the kinetic energy of the tape in the Lagrangian, we derive equations of motion that support stick-slip jumps as a natural consequence of the inherent dynamics. In the low mass limit, these equations reproduce solutions obtained using a differential-algebraic algorithm introduced for the earlier equations. Our analysis also shows that the mass of the ribbon has a strong influence on the nature of the dynamics.

  15. Time scales of the stick–slip dynamics of the peeling of an adhesive tape

    PubMed Central

    Mishra, Nachiketa; Parida, Nigam Chandra; Raha, Soumyendu

    2015-01-01

    The stick–slip dynamics of the peeling of an adhesive tape is characterized by bifurcations that have been experimentally well studied. In this work, we investigate the time scale in which the the stick–slips happen leading to the bifurcations. This is fundamental to understanding the triboluminescence and acoustic emissions associated with the bifurcations. We establish a relationship between the time scale of the bifurcations and the inherent mathematical structure of the peeling dynamics by studying a characteristic time quantity associated with the dynamics. PMID:25663802

  16. Development and production of a flame retardant, general purpose, pressure sensitive adhesive tape

    NASA Technical Reports Server (NTRS)

    Monaghan, P. B.; Doggett, R. H.

    1977-01-01

    The specification results for the finished tape properties were as follows: (1) adhesive strength (180 deg peel) on aluminum from 107 to 143 grams per centimeter (0.6 to 0.8 pounds per inch); (2) adhesive strength (180 deg peel) on stainless steel from 71 to 107 grams per centimeter (0.4 to 0.6 pounds per inch); (3) unwind resistance of 536 to 714 grams per centimeter (3 to 4 pounds per inch); (4) tensile strength minimum of 7143 grams per centimeter (40 pounds per inch); (5) elongation from 5 to 10% at break; (6) tear strength, Elmendorf from 200 to 350 grams (0.44 to 0.77 pounds); and (7) tear strength, tongue from 363 to 408 grams (0.8 to 0.9) pounds).

  17. Adhesive-tape soft lithography for patterning mammalian cells: application to wound-healing assays.

    PubMed

    Shrirao, Anil B; Hussain, Ali; Cho, Cheul H; Perez-Castillejos, Raquel

    2012-09-13

    This paper introduces a benchtop method for patterning mammalian cells-i.e., for culturing cells at specific locations-on planar substrates. Compared with standard cell culture techniques, which do not allow the control of what areas of a monolayer are populated by one type of cell or another, techniques of cell patterning open new routes to cell biology. Researchers interested in cell patterning, however, are often times hindered by limited access to photolithographic capabilities. This paper shows how cells can be patterned easily with sub-millimeter precision using a non-photolithographic technique that is based on the use of office adhesive tape and poly(dimethylsiloxane) (PDMS). This method is fast (~4 h to go from a layout to have the cells patterned in the shape of such layout) and only requires materials and tools readily available in a conventional biomedical laboratory. A wound-healing assay is presented here that illustrates the potential of the technique (which we call tape-based soft lithography) for patterning mammalian cells and studying biologically significant questions such as collective cellular migration.

  18. Humidity effects on adhesion of nickel-zinc ferrite in elastic contact with magnetic tape and itself

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.; Kusaka, T.; Maeda, C.

    1985-01-01

    The effects of humidity on the adhesion of Ni-Zn ferrite and magnetic tape in elastic contact with a Ni-Zn ferrite hemispherical pin in moist nitrogen were studied. Adhesion was independent of normal load in dry, humid, and saturated nitrogen. Ferrites adhere to ferrites in a saturated atmosphere primarily from the surface tension effects of a thin film of water adsorbed on the ferrite surfaces. The surface tension of the water film calculated from the adhesion results was 48 times 0.00001 to 56 times 0.00001 N/cm; the accepted value for water is 72.7 x 0.00001 N/cm. The adhesion of ferrite-ferrite contacts increased gradually with increases in relative humidity to 80 percent, but rose rapidly above 80 percent. The adhesion at saturation was 30 times or more greater than that below 80 percent relative humidity. Although the adhesion of magnetic tape - ferrite contacts remained low below 40 percent relative humidity and the effect of humidity was small, the adhesion increased considerably with increasing relative humidity above 40 percent. The changes in adhesion of elastic contacts were reversible on humidifying and dehumidifying.

  19. Raman microspectroscopic chemical mapping and chemometric classification for the identification of gunshot residue on adhesive tape.

    PubMed

    Bueno, Justin; Lednev, Igor K

    2014-07-01

    A novel approach utilizing automated Raman microspectroscopic mapping for gunshot residue (GSR) detection was investigated. A well-established technique for GSR recovery (tape lifting) was utilized for GSR particle collection. Uncontaminated samples of the substrate (tape), organic GSR (OGSR), and inorganic GSR (IGSR) particles were characterized to generate three respective Raman spectroscopic training sets. Automated Raman mapping was used to rapidly collect spectra over areas of the tape substrate populated with GSR particles. Raman spectra collected from the maps were classified against the training sets via partial least squares discriminant analysis (PLS-DA) to determine if GSR was present. We report the application of Raman chemical mapping as a proof of concept for the positive detection of GSR particles of varying morphologies. The estimated size of GSR particles, which could be readily detected by this method, is about 3.4 μm. The efficiency of the classification was quantitated with rates of true positives and negatives. Validation studies scrutinizing the practicality of this approach as a viable tool for potential forensics investigations are currently in progress.

  20. Adhesive-tape recovery combined with molecular and microscopic testing for the detection of Cryptosporidium oocysts on experimentally contaminated fresh produce and a food preparation surface.

    PubMed

    Fayer, Ronald; Santin, Monica; Macarisin, Dumitru; Bauchan, Gary

    2013-04-01

    A proof of concept study was conducted to determine if transparent double-sided adhesive tape could be used to recover and detect [by polymerase chain reaction (PCR) and immunofluorescence microscopy (IFA)] Cryptosporidium parvum oocysts on fresh produce and on a food preparation surface. Oocysts were applied on the surface of ten apples, ten peaches, eight cucumbers, and eight tomatoes within circles drawn with a permanent marker. Approximately 18 h later, skin excised from three uncontaminated and three contaminated circles from each piece of produce was subjected to PCR. Pieces of transparent double-sided adhesive tape were lightly pressed onto the surface of three other contaminated circles and examined by PCR. Other pieces of adhesive tape were pressed against the surfaces of three other circles and examined by IFA. At concentrations of 100 and 50 oocysts per circle, every produce item examined by PCR of contaminated excised skin was found positive, and every item examined by adhesive tape subjected to PCR and IFA was found positive, except one. At ten oocysts per circle, every produce item was found positive by PCR of contaminated excised skin, and all apples, cucumbers, and tomatoes were found positive by adhesive tape subjected to IFA. Detection of low numbers of oocysts on peaches by IFA examination of adhesive tape was problematic because trichomes that cover peaches and impart the fuzzy surface partially restrict the tape from reaching some areas where oocysts adhere. Tape combined with IFA was successful in recovering and identifying oocysts from six areas of laminate countertop where the oocysts had been applied and allowed to dry for 30-60 min. These are the first findings to demonstrate that adhesive tape can be used to recover and identify a protozoan parasite from fresh produce and from a laminate food preparation surface.

  1. Comparison of particle sampling results from tape lifts and solvent rinses

    NASA Astrophysics Data System (ADS)

    Egges, Joanne; Devaud, Genevieve; Rockwell, Christina M.; Matheson, Bruce A.

    2012-10-01

    Historical experience and previously published papers have shown that contamination sampling techniques influence the cleanliness results of spaceflight hardware. Programs rely on this data to show that derived or contractual requirements are met at delivery. Particle sampling using tape lifts and rinses was performed on the James Webb Space Telescope (JWST) Primary Mirror Segment Assemblies (PMSAs) hardware. Sampling was performed on identical hardware with both sampling techniques. The hardware was sampled at comparable stages of assembly which provided hardware with similar levels of particulate contamination. Results from the two sampling techniques are compared. In one technique, sampling was performed by rinsing (with a hand-squeeze bottle with low pressure) followed by a tape lift; the other technique used a tape lift only. The relationship of particle size distribution, types of particles, level of particle contamination, and particle removal rate by sampling technique are examined. Comparison of the particle sampling results provides a basis for interpreting results depending on sampling techniques. Improving the contamination engineer's ability to interpret results is particularly useful when hardware configuration or surface finish dictate which sampling technique can be used. When one can choose the sampling technique, the results of this study can provide guidance on which technique is more appropriate depending on the circumstances. Results show that tape lifts remove more particles than low pressure rinses; furthermore that tape lift only is better than the combined operation of a rinse closely followed by a tape lift. Results also indicate that further work should be performed on different surface finishes, rinsing techniques, and particulate contamination levels.

  2. Thermocouple tape

    NASA Technical Reports Server (NTRS)

    Thomas, R. D. (Inventor)

    1973-01-01

    A thermocouple which may be rolled as a tape until needed and a method of making it are described. Thermoelectrically different metals are applied to a strip of electrically nonconductive material in longitudinally overlapping relationship. Apertures may be provided along the tape in overlapping region at predetermined intervals. An adhesive material is applied to the side of the tape opposite the thermoelectric metals either before or after the thermoelectric metals are deposited. The tape may be cut or torn to form a thermocouple device which is ready for application to a body whose temperature is to be monitored or measured.

  3. Note: Adhesive stamp electrodes using spider silk masks for electronic transport measurements of supra-micron sized samples

    NASA Astrophysics Data System (ADS)

    Steven, E.; Jobiliong, E.; Eugenio, P. M.; Brooks, J. S.

    2012-04-01

    A procedure for fabricating adhesive stamp electrodes based on gold coated adhesive tape used to measure electronic transport properties of supra-micron samples in the lateral range 10-100 μm and thickness >1 μm is described. The electrodes can be patterned with a ˜4 μm separation by metal deposition through a mask using Nephila clavipes spider dragline silk fibers. Ohmic contact is made by adhesive lamination of a sample onto the patterned electrodes. The performance of the electrodes with temperature and magnetic field is demonstrated for the quasi-one-dimensional organic conductor (TMTSF)2PF6 and single crystal graphite, respectively.

  4. Five year magnetic tape for unattended satellite tape recorders

    NASA Technical Reports Server (NTRS)

    Benn, G. S. L.; Gutfreund, K.

    1972-01-01

    The development and fabrication of a quantity of long life magnetic tape with properties selected specifically for unattended operation in spacecraft tape recorders was studied. A detailed analytical consideration of various binder systems was undertaken. This included the chemical aspects of the binders, cohesion and adhesion effects, stability and the mechanical and physical properties. The ability to form free films of these polymers and their combination with various oxide loadings and other additives allowed a rapid selection of four polymer candidates for a five year magnetic tape. Samples were evaluated under actual running conditions which included physical, magnetic, and extensive life testing. These sample tapes withstood 50,000 bidirectional tape passes under fairly harsh operating conditions.

  5. NASA Global Atmospheric Sampling Program (GASP) data report for tape VL0005

    NASA Technical Reports Server (NTRS)

    Holdeman, J. D.; Humenik, F. M.

    1977-01-01

    Atmospheric ozone, water vapor, and related flight and meteorological data were obtained during 214 flights of a United Airlines B-747 and two Pan American World Airways B-747's from March through June 1976. In addition, trichlorofluoromethane data obtained from laboratory analysis of two whole air samples collected in flight are reported. These data are available on GASP tape VL0005 from the National Climatic Center, Asheville, North Carolina. In addition to the GASP data, tropopause pressure fields obtained from NMC archives for the dates of the GASP flights are included on the data tape. Flight routes and dates, instrumentation, data processing procedures, and data tape specifications are described in this report. Selected analyses including ozone and sample bottle data are also presented.

  6. A technique to eliminate subgingival cement adhesion to implant abutments by using polytetrafluoroethylene tape.

    PubMed

    Hess, Timothy A

    2014-08-01

    Residual excess cement adhered subgingivally to an implant abutment has the potential to cause periimplant mucositis or periimplant disease. This article describes a procedure in which polytetrafluoroethylene (PTFE) tape is used to protect dental cements from adhering to the implant abutment. This technique ensures complete removal of cement from the implant abutment after seating of the crown.

  7. Thermocouple tape

    NASA Technical Reports Server (NTRS)

    Mazaris, G. A., Jr.; Thomas, R. D.

    1972-01-01

    Preformed, low cost, thin film thermocouples on adhesive tapes were fabricated. Metal strips of two dissimilar metals were laid on opposite edges of plastic substrate so that they overlap in center portion, forming thermocouple junction. Useful temperature range for polyimide films was 4 to 673 K.

  8. Fatigue study and improve reliability of cantilever type micro piezoelectric energy harvesters reinforced with flexible adhesive conductive tape

    NASA Astrophysics Data System (ADS)

    Lin, T. K.; Hsieh, Y. C.; Chen, C. T.; Chen, J. J.; Wu, W. J.

    2016-04-01

    Cantilever type piezoelectric energy harvester (PEH) is widely adopted in the design of vibration energy harvesters because of simple, effective and easy to fabricate. When the PEH is working under excitation of continuous vibration sources, like mounting on motors, reliability and durability is a major concern. The failure mode and fatigue issues will be important design considerations in field applications. Since the largest strain of a cantilever structure is located in the clamping position of fixed end, the location is therefore the weakest point of the structure and the hot zone of mechanical cracks. The failure mode due to fatigue under long time excitation of vibration sources is typically continuously developing small cracks on the piezoelectric PZT films till tearing the surface electrodes and caused open circuit to the output circuitry. Therefore, extending the lifetime with minimize the surface electrodes cracking becomes a key point for field applications. Previously, we focused on the output performance of PEH. At PowerMEMS 2014 [1], we presented a high performance PEH based on PZT thin films fabricated with a homemade PZT deposition equipment on stainless steel substrates. We confirmed that the stainless steel based PEH can generate better output power than silicon based devices under the same vibration excitation levels, and also the stainless based PEH can have longer lifetime when excited at higher vibration levels due to better mechanical strength. In this study, we tried to further reinforce the PEH with a conductive adhesive tape sticking on the surface electrode near the clamping position. We investigated the change of failure mode and mechanical behaviors, including the frequency bandwidth and non-linearity of the piezoelectric energy harvester. The PEH devices was mounted on a shaker for long time testing with vibration frequency set around 120Hz at 0.5g, 0.6g, and 0.7g acceleration vibration levels. The electrodes of the PEH device were

  9. NASA Global Atmospheric Sampling Program (GASP) data report for tape VL0014

    NASA Technical Reports Server (NTRS)

    Briehl, D.; Dudzinski, T. J.; Liu, D. C.

    1980-01-01

    The data currently available from GASP, including flight routes and dates, instrumentation, data processing procedures, and data tape specifications are described. Measurements of atmospheric ozone, cabin ozine, carbon monoxide, water vapor, particles, clouds, condensation nuclei, filter samples and related meteorological and flight information obtained during 562 flights of aircraft N533PA, N4711U, N655PA, and VH-EBE from October 3, 1977 through January 5, 1978 are reported. Data representing tropopause pressures obtained from time and space interpolation of National Meteorological Center archived data for the dates of the flights are included.

  10. NASA Global Atmospheric Sampling Program (GASP) data report for tape VL0006

    NASA Technical Reports Server (NTRS)

    Gauntner, D. J.; Holdeman, J. D.; Humenik, F. M.

    1977-01-01

    The NASA Global Atmospheric Sampling Program (GASP) is obtaining measurements of atmospheric trace constituents in the upper troposphere and lower stratosphere using fully automated air sampling systems on board several commercial B-747 aircraft in routine airline service. Atmospheric ozone, and related flight and meteorological data were obtained during 245 flights of a Qantas Airways of Australia B-747 and two Pan American World Airways B-747s from July 1976 through September 1976. In addition, whole air samples, obtained during three flights, were analyzed for trichlorofluoromethane, and filter samples, obtained during four flights, were analyzed for sulfates, nitrates, fluorides, and chlorides. Flight routes and dates, instrumentation, data processing procedures, data tape specifications, and selected analyses are discussed.

  11. NASA Global Atmospheric Sampling Program (GASP) data report for tape VL0004

    NASA Technical Reports Server (NTRS)

    Holdeman, J. D.; Humenik, F. M.; Lezberg, E. A.

    1976-01-01

    The NASA Global Atmospheric Sampling Program (GASP) is obtaining measurements of atmospheric trace constituents in the upper troposphere and lower stratosphere using fully automated air sampling systems on board several commercial B-747 aircraft in routine airline service. Atmospheric ozone, water vapor, and related flight and meteorological data were obtained during 139 flights of a United Airlines B-747 and a Pan American World Airways B-747 from December 1975 through March 1976. In addition, sample bottles were exposed during three flights and analyzed for trichlorofluoromethane, and filter samples were exposed during five flights and analyzed for sulfates, nitrates, and chlorides. Flight routes and dates, instrumentation, data processing procedures, data tape specifications, and selected analyses are discussed.

  12. Comparisons of jitter, shimmer, and signal-to-noise ratio from directly digitized versus taped voice samples.

    PubMed

    Gelfer, M P; Fendel, D M

    1995-12-01

    The purpose of this study was to compare jitter, shimmer, and signal-to-noise ratio (SNR) measures obtained from tape-recorded samples with the same measures made on directly digitized voice samples, with use of the CSpeech acoustic analysis program. Subjects included 30 young women who phonated the vowel /a/ at a comfortable pitch and loudness level. Voice samples were simultaneously recorded and digitized, and the resulting perturbation measures for the two conditions were compared. Results indicated that there were small but statistically significant differences between percent jitter, percent shimmer, and SNR calculated from taped samples compared with the same measures calculated from directly digitized samples. It was concluded that direct digitization for clinical measures of vocal perturbation was most desirable, but that taped samples could be used, if necessary, with some caution.

  13. How to Tape an Ankle

    MedlinePlus

    ... Materials needed: 1½" athletic tape, Tuf-Skin/Quick Drying Adhesive, two pads to help prevent blistering (2" ... the start of the calf muscle. Use the spray adhesive to help secure the pre-wrap. Apply ...

  14. An evaluation of adhesive sample holders for advanced crystallographic experiments

    SciTech Connect

    Mazzorana, Marco; Sanchez-Weatherby, Juan Sandy, James; Lobley, Carina M. C.; Sorensen, Thomas

    2014-09-01

    Commercially available adhesives have been evaluated for crystal mounting when undertaking complex macromolecular crystallography experiments. Here, their use as tools for advanced sample mounting and cryoprotection is assessed and their suitability for room-temperature data-collection and humidity-controlled studies is investigated. The hydration state of macromolecular crystals often affects their overall order and, ultimately, the quality of the X-ray diffraction pattern that they produce. Post-crystallization techniques that alter the solvent content of a crystal may induce rearrangement within the three-dimensional array making up the crystal, possibly resulting in more ordered packing. The hydration state of a crystal can be manipulated by exposing it to a stream of air at controlled relative humidity in which the crystal can equilibrate. This approach provides a way of exploring crystal hydration space to assess the diffraction capabilities of existing crystals. A key requirement of these experiments is to expose the crystal directly to the dehydrating environment by having the minimum amount of residual mother liquor around it. This is usually achieved by placing the crystal on a flat porous support (Kapton mesh) and removing excess liquid by wicking. Here, an alternative approach is considered whereby crystals are harvested using adhesives that capture naked crystals directly from their crystallization drop, reducing the process to a one-step procedure. The impact of using adhesives to ease the harvesting of different types of crystals is presented together with their contribution to background scattering and their usefulness in dehydration experiments. It is concluded that adhesive supports represent a valuable tool for mounting macromolecular crystals to be used in humidity-controlled experiments and to improve signal-to-noise ratios in diffraction experiments, and how they can protect crystals from modifications in the sample environment is discussed.

  15. NASA Global Atmospheric Sampling Program (GASP) data report for tapes VL0010 and VL0012

    NASA Technical Reports Server (NTRS)

    Holdeman, J. D.; Dudzinski, T. J.; Tiefermann, M. W.; Nyland, T. W.

    1979-01-01

    The GASP atmospheric trace constituent data currently available are considered. Included on tapes are in-situ measurements of atmospheric ozone, carbon monoxide, water vapor, and clouds, data from laboratory analysis of filters exposed in flight, and related flight and meteorological data. Measurements of ozone levels within the first class cabin of these aircraft are also reported. In addition to the GASP data, tropopause pressures obtained from time and space interpolation of NMC archived data for the dates of the flights are included. Reported herein are the flight routes and dates, instrumentation, data processing procedures, data tape specifications, and analyses of the cabin ozone measurements.

  16. An evaluation of adhesive sample holders for advanced crystallographic experiments.

    PubMed

    Mazzorana, Marco; Sanchez-Weatherby, Juan; Sandy, James; Lobley, Carina M C; Sorensen, Thomas

    2014-09-01

    The hydration state of macromolecular crystals often affects their overall order and, ultimately, the quality of the X-ray diffraction pattern that they produce. Post-crystallization techniques that alter the solvent content of a crystal may induce rearrangement within the three-dimensional array making up the crystal, possibly resulting in more ordered packing. The hydration state of a crystal can be manipulated by exposing it to a stream of air at controlled relative humidity in which the crystal can equilibrate. This approach provides a way of exploring crystal hydration space to assess the diffraction capabilities of existing crystals. A key requirement of these experiments is to expose the crystal directly to the dehydrating environment by having the minimum amount of residual mother liquor around it. This is usually achieved by placing the crystal on a flat porous support (Kapton mesh) and removing excess liquid by wicking. Here, an alternative approach is considered whereby crystals are harvested using adhesives that capture naked crystals directly from their crystallization drop, reducing the process to a one-step procedure. The impact of using adhesives to ease the harvesting of different types of crystals is presented together with their contribution to background scattering and their usefulness in dehydration experiments. It is concluded that adhesive supports represent a valuable tool for mounting macromolecular crystals to be used in humidity-controlled experiments and to improve signal-to-noise ratios in diffraction experiments, and how they can protect crystals from modifications in the sample environment is discussed.

  17. NASA Global Atmospheric Sampling Program (GASP) data report for tape VL0009

    NASA Technical Reports Server (NTRS)

    Holdeman, J. D.; Dudzinski, T. J.; Nyland, T. W.; Tiefermann, M. W.

    1978-01-01

    The GASP atmospheric trace constituent data cover atmospheric ozone, carbon monoxide, condensation nuclei, clouds, and related meteorological and flight information obtained during October 28-31, 1977. Reported herein are flight routes and dates, instrumentation, data processing procedures, and data tape specifications.

  18. A Comparison of the Haider Tube-Guard® Endotracheal Tube Holder Versus Adhesive Tape to Determine if This Novel Device Can Reduce Endotracheal Tube Movement and Prevent Unplanned Extubation

    PubMed Central

    Buckley, Jack C.; Brown, Adam P.; Shin, John S.; Rogers, Kirsten M.

    2016-01-01

    BACKGROUND: Endotracheal tube security is a critical safety issue. We compared the mobility of an in situ endotracheal tube secured with adhesive tape to the one secured with a new commercially available purpose-designed endotracheal tube-holder device (Haider Tube-Guard®). We also observed for the incidence of oropharyngeal or facial trauma associated with the 2 tube fixation methods. METHODS: Thirty adult patients undergoing general anesthesia with neuromuscular blockade were prospectively enrolled. Immediately after intubation, a single study author positioned the endotracheal tube tip in the distal trachea using a bronchoscope. Anesthesiologists caring for patients secured the tube in their normal fashion (always with adhesive tape). A force transducer was used to apply linear force, increasing to 15 N or until the principal investigator deemed that the force be aborted for safety reasons. The displacement of the endotracheal tube was measured with the bronchoscope. Any tape was then removed and the endotracheal tube secured with the Haider Tube-Guard device. The linear force was reapplied and the displacement of the endotracheal tube measured. The Haider Tube-Guard device was left in place for the duration of the case. The patient’s face and oropharynx were examined for any evidence of trauma during surgery and in the recovery room. On discharge from the postanesthesia care unit, the patient answered a brief survey assessing for any subjective evidence of minor facial or oropharyngeal trauma. RESULTS: Under standardized tension, the endotracheal tube withdrew a mean distance of 3.4 cm when secured with adhesive tape versus 0.3 cm when secured with the Haider Tube-Guard (P <0.001). Ninety-seven percent of patients (29/30) experienced clinically significant endotracheal tube movement (>1 cm) when adhesive tape was used to secure the tube versus 3% (1/30) when the Haider Tube-Guard was used (P <0.001). Thirty percent of patients (9/30) were potentially deemed

  19. Quick-release medical tape.

    PubMed

    Laulicht, Bryan; Langer, Robert; Karp, Jeffrey M

    2012-11-13

    Medical tape that provides secure fixation of life-sustaining and -monitoring devices with quick, easy, damage-free removal represents a longstanding unmet medical need in neonatal care. During removal of current medical tapes, crack propagation occurs at the adhesive-skin interface, which is also the interface responsible for device fixation. By designing quick-release medical tape to undergo crack propagation between the backing and adhesive layers, we decouple removal and device fixation, enabling dual functionality. We created an ordered adhesive/antiadhesive composite intermediary layer between the medical tape backing and adhesive for which we achieve tunable peel removal force, while maintaining high shear adhesion to secure medical devices. We elucidate the relationship between the spatial ordering of adhesive and antiadhesive regions to create a fully tunable system that achieves strong device fixation and quick, easy, damage-free device removal. We also described ways of neutralizing the residual adhesive on the skin and have observed that thick continuous films of adhesive are easier to remove than the thin islands associated with residual adhesive left by current medical tapes.

  20. Forensic utility of carbon isotope ratio variations in PVC tape backings.

    PubMed

    Dietz, Marianne E; Stern, Libby A; Mehltretter, Andria Hobbs; Parish, Ashley; McLasky, Velvet; Aranda, Roman

    2012-03-01

    Forensic interest in adhesive tapes with polyvinyl chloride (PVC) backings (electrical tape) derives from their use in a variety of illicit activities. Due to the range of physical characteristics, chemical compositions, and homogeneity within a single roll of tape, traditional microscopic and chemical analyses can offer a high degree of discrimination between tapes, permitting the assessment of potential associations between evidentiary tape samples. The carbon isotope ratios of tapes could provide additional discrimination among tape samples. To evaluate whether carbon isotope ratios may be able to increase discrimination of electrical tapes, particularly with regards to different rolls of tape of the same product, we assessed the δ(13)C values of backings from 87 rolls of PVC-based black electrical tape (~20 brands, >60 products) Prior to analysis, adhesives were removed to prevent contamination by adhering debris, and plasticizers were extracted because of concern over their potential mobility. This result is consistent with each of these tapes having approximately the same plasticizer δ(13)C value and proportion of carbon in these plasticizers. The δ(13)C values of the 87 PVC tape backings ranged between -23.5 and -41.3 (‰, V-PDB), with negligible carbon isotopic variation within single rolls of tape, yet large variations among tape brands and tape products. Within this tape population, carbon isotope ratios permitted an average exclusion power of 93.7%, using a window of +/-0.3‰; the combination of carbon isotope ratio measurement with additional chemical and physical analyses raises the discrimination power to over 98.9%, with only 41 out of a possible 3741 pairs of tape samples being indistinguishable. There was a linear relationship between the δ(13)C value of tape backings and the change in δ(13)C value with the extraction of plasticizers. Analyses of pre- and post-blast tape sample pairs show that carbon isotope signatures are within 0.3‰ of

  1. Pressure Roller For Tape-Lift Tests

    NASA Technical Reports Server (NTRS)

    Abrams, Eve

    1991-01-01

    Rolling device applies nearly constant, uniform pressure to surface. Simple tool exerts nearly constant pressure via compression of sheath by fixed amount. Pins hold wheels on cylinder and cylinder on tangs of handle. Cylinder and handle made of metal or plastic. Sheath press-fit or glued to cylinder. End pins attached to cylinder by adhesive or screw threads. Device intended for use in taking tape-lift samples of particulate contamination on surface.

  2. Duct Tape Durability Testing

    SciTech Connect

    Sherman, Max H.; Walker, Iain S.

    2004-04-01

    Duct leakage is a major source of energy loss in residential buildings. Most duct leakage occurs at the connections to registers, plenums, or branches in the duct system. At each of these connections, a method of sealing the duct system is required. Typical sealing methods include tapes or mastics applied around the joints in the system. Field examinations of duct systems have shown that taped seals tend to fail over extended periods of time. The Lawrence Berkeley National Laboratory (LBNL) has been testing sealant durability for several years using accelerated test methods and found that typical duct tape (i.e., cloth-backed tapes with natural rubber adhesives) fails more rapidly than other duct sealants. This report summarizes the results of duct sealant durability testing over two years for four UL 181B-FX listed duct tapes (two cloth tapes, a foil tape and an Oriented Polypropylene (OPP) tape). One of the cloth tapes was specifically developed in collaboration with a tape manufacturer to perform better in our durability testing. The tests involved the aging of common ''core-to-collar joints'' of flexible duct to sheet metal collars. Periodic air leakage tests and visual inspection were used to document changes in sealant performance. After two years of testing, the flex-to-collar connections showed little change in air leakage, but substantial visual degradation from some products. A surprising experimental result was failure of most of the clamps used to mechanically fasten the connections. This indicates that the durability of clamps also need to be addressed ensure longevity of the duct connection. An accelerated test method developed during this study has been used as the basis for an ASTM standard (E2342-03).

  3. Forensic utility of the carbon isotope ratio of PVC tape backings

    NASA Astrophysics Data System (ADS)

    Stern, L. A.; Thompson, A. H.; Mehltretter, A. H.; McLaskey, V.; Parish, A.; Aranda, R.

    2008-12-01

    Forensic interest in adhesive tapes with PVC-backings (polyvinyl chloride, electrical tapes) derives from their use in construction of improvised explosive devices, drug packaging and in a variety of other illicit activities. Due to the range of physical characteristics and chemical compositions of such tapes, traditional microscopic and chemical analysis of the tape backings and adhesives offer a high degree of discrimination between tapes from different manufacturers and products. To evaluate whether carbon isotope ratios may be able to increase discrimination of electrical tapes, particularly with regards to different tapes of the same product, we assessed the PVC-backings of 87 rolls of black electrical tape for their δ13C values. The adhesive on these tapes was physically removed with hexane, and plasticizers within the PVC tape backings were removed by three-20 minute extractions with chloroform. The δ13C values of the PVC tape backings ranged between -23.8 and -41.5 (‰ V-PDB). The carbon isotopic variation within a product (identical brand and product identification) is significant, based on five products with at least 3 rolls (ranges of 7.4‰ (n=3), 10.0‰ (n=6), 4.2‰ (n=16), 3.8‰ (n=6), and 11.5‰ (n=8), respectively). There was no measurable carbon isotope variation in regards to the following: a) along the length of a roll (4 samples from 1 roll); b) between the center and edge of a strip of tape (1 pair); c) between rolls assumed to be from the same lot of tape (2 pairs); d) between different rolls from the same batch of tape (same product purchased at the same time and place; 5 pairs); and e) between samples of a tape at room temperature, heated to 50° C and 80° C for 1 week. For each sample within the population of 87 tapes, carbon isotopes alone exclude 80 to 100% of the tapes as a potential match, with an average exclusion power of 92.5%, using a window of ± 0.4‰. Carbon isotope variations originate from variations in starting

  4. Video-taped sample evaporation in hot chambers simulating gas chromatography split and splitless injectors. II. Injection with band formation.

    PubMed

    Grob, K; Biedermann, M

    2000-11-03

    The processes in devices imitating a vaporising injector were video-taped using perylene as a fluorescent marker for non-evaporated sample. Processes are summarised which are observed after the sample liquid passed through a cool needle and left as a band of liquid moving at high velocity (as typical for injection by fast autosamplers). This liquid is shot past the column entrance unless stopped either by a packing, e.g., wool or by suitable obstacles. Packings of low thermal mass are locally cooled to the solvent boiling point and suck in the liquid. Stopping the liquid by obstacles is more difficult because solvent vapours prevent contact of the liquid with the hot surfaces, and was reliably achieved only by the laminar liner. For the same reason, transfer onto the liner wall only occurs for higher boiling liquids.

  5. Adhesions

    MedlinePlus

    Adhesions are bands of scar-like tissue. Normally, internal tissues and organs have slippery surfaces so they can shift easily as the body moves. Adhesions cause tissues and organs to stick together. They ...

  6. Adhesion

    MedlinePlus

    ... the intestines, adhesions can cause partial or complete bowel obstruction . Adhesions inside the uterine cavity, called Asherman syndrome , ... 1. Read More Appendicitis Asherman syndrome Glaucoma Infertility Intestinal obstruction Review Date 4/5/2016 Updated by: Irina ...

  7. Shear wave velocity measurements of thin epoxy adhesive samples using broadband EMATs

    NASA Astrophysics Data System (ADS)

    Dixon, S.; Edwards, C.; Palmer, S. B.

    2002-05-01

    This paper describes an ultrasonic analysis of thin epoxy resin samples using normal incidence radially polarized shear wave ElectroMagnetic Acoustic Transducers (EMATs). The adhesive thickness in the first set of experiments was approximately 0.5 mm. The adhesive used in the first set of experiments was obtained from a 2 component cartridge and it was found that adhesive extruded from such cartridges can be inhomogeneous within the same cartridge. The second experiment described here demonstrated how material property changes of a thin adhesive layer (70 μm) could be ultrasonically measured during cure via spectral analysis.

  8. Tamper tape seals

    SciTech Connect

    Wright, B.W.; Undem, H.A.

    1994-07-01

    Tamper tapes are appealing for many applications due to their ease of use and relative robustness. Applications include seals for temporary area denial, protection of sensitive equipment, chain-of-custody audit trails, and inventory control practices. A next generation of adhesive tamper tapes is being developed that combines the best features of commercially available devices with additional state-of-the-art features in tamper indication, tamper-resistance, and counterfeit-resistance. The additional features are based on U.S. Department of Energy (DOE) research and development (R&D) activities that were originally associated with preparations for the Strategic Arms Reduction Treaty (START). New features include rapid-set, chemical-cure adhesive systems that allow user-friendly application and layered levels of counterfeit-resistance based on unique {open_quotes}fingerprint{close_quotes} characteristics that can be accessed as desired.

  9. Industrial Tape

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Scotch Brand Tape 364 was developed for NASA by 3M Company to protect electrical instrumentation coils and fluid lines from rocket launch blast conditions. It is an aluminized glass cloth tape which can withstand very high temperatures, is easily applied to compound surfaces, has excellent solar energy reflectance, and does not present an electrostatic hazard. It has potential automotive, transportation, and building construction applications.

  10. FGGE/ERBZ tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The FGGE/ERBZ tape contains 5 parameters which are extracted and reformatted from the Nimbus-7 ERB Zonal Means Tape. There are three types of files on a FGGE/ERBZ tape: a tape header file, and data files. Physical characteristics, gross format, and file specifications are given. A sample tape check/document printout (shipping letter) is included.

  11. Importance of a suitable working protocol for tape stripping experiments on porcine ear skin: Influence of lipophilic formulations and strip adhesion impairment.

    PubMed

    Nagelreiter, C; Mahrhauser, D; Wiatschka, K; Skipiol, S; Valenta, C

    2015-08-01

    The tape stripping method is a very important tool for dermopharmacokinetic experiments in vitro and the accurate measurement of the removed corneocytes is key for a reliable calculation of a drug's skin penetration behavior. Therefore, various methods to quantify the amount of corneocytes removed with each tape strip have been employed, ranging from gravimetric approaches to protein assays and recently near infrared densitometry (NIR) has become very widely used. As this method is based on a reduction of light intensity, interference of formulation components seems conceivable, as they could scatter light and change the results. In this study, NIR measurements were compared to a protein assay and in addition, the influence of highly lipophilic formulations on the results of tape stripping experiments was investigated as impairment of the adherence of strips has been reported. To this end, different tape stripping protocols were employed. The obtained results ensure suitability of the NIR method and moreover suggest a more pronounced influence on adherence with increasing lipophilicity in applied formulations. The results show that adaptation of the tape stripping protocol to the specifications of envisioned experiments is important for reliable results. Two protocols were found favorable and are presented in this work.

  12. Magnetic tape

    NASA Technical Reports Server (NTRS)

    Robinson, Harriss

    1992-01-01

    The move to visualization and image processing in data systems is increasing the demand for larger and faster mass storage systems. The technology of choice is magnetic tape. This paper briefly reviews the technology past, present, and projected. A case is made for standards and the value of the standards to users.

  13. Extraction of matrix resistivity from short samples of superconducting multifilamentary composite tapes: influence of strand twist and internal structure

    NASA Astrophysics Data System (ADS)

    Sumption, M. D.; Lee, E.; Dou, S. X.; Collings, E. W.

    2000-06-01

    An expression for loss in untwisted, aspected strands (aspect ratio a/ b) has been used to extract the effective transverse matrix resistivity, ρ⊥, of NbTi/Cu and Bi-based multifilamentary strands with low numbers of filaments in coarse arrays. The ρ⊥ values were significantly higher than expected for both strand types by factors of 5-10. This was attributed to filament array coarseness and geometry, and was predicted to be much more noticeable for untwisted than twisted tapes. Additionally, a loss equation is given for the special case of twisted tapes with resistive cores. Here, the loss is estimated to be about a/ b times lower than the uncored case.

  14. Technique for recovery of voice data from heat damaged magnetic tape

    NASA Technical Reports Server (NTRS)

    Melugin, J. F.; Obrien, D. E., III (Inventor)

    1974-01-01

    A method for conditioning, and thus enabling retrieval of intelligence from, magnetic tapes after damage from heat has caused the tape to wrinkle and curl severely thereby reducing tape width to less than one-half its original size. The damaged tape is superposed on a first piece of splicing tape with the oxide side of the magnetic tape in contact with the adhesive side of the splicing tape and then carefully smoothed by a special tool. A second piece of splicing tape is placed on the backing side of the magnetic tape then the resulting tape stack is trimmed to the original width of the magnetic tape. After the first piece of splicing tape is carefully removed from the oxide side of the damaged magnetic tape, the resulting magnetic tape is then ready to be placed into a recorder for playback.

  15. What's up with duct tape

    SciTech Connect

    Walker, Iain S.; Sherman, Max H.

    2005-03-01

    Recent research suggests that almost any tape can be made to work for a core-to-collar joint when perfectly applied. Given all the better choices available and all the problems that can and do occur in the field, we would not recommend that cloth-backed (natural) rubber-adhesive tapes be used, unless they can pass a suitable E2343 test. If visual degradation is an important factor, Oriented Polypropylene (OPP) and cloth-backed tapes should be avoided. While tapes that fail usually show visual degradation, the converse is not always true. We speculate, however, that visually degraded tapes are more likely to be susceptible to damage from vibration and other mechanical stresses. Conventional nylon straps are quite prone to fail at higher temperatures, but no systematic studies have yet been done across product classes. UL has proposed a new standard for straps, but the protocol for the current UL test does not, however, suggest that it would be a good indicator of durability. Products meeting the new UL standard for straps should be independently tested for the failure modes observed in the field and laboratory to determine if that test is a reasonable indicator of durability. Until a suitable test for strap durability exists, they recommend that only high temperature nylon or metal straps be used--especially in cases where tapes may be sensitive to mechanical stresses.

  16. Enhancing contrast of fingerprints on plastic tape.

    PubMed

    Steele, Charles A; Ball, Mikki S

    2003-11-01

    Many of the currently available fingerprinting methods have limited ability to visualize fingerprints on plastic tape without expensive equipment or significant handling of the sample. This is especially true for visualizing fingerprints on black electrical tape. This study sought a hands-off method to produce easy visualization of fingerprints on different types of plastic tape, including black electrical tape, without the need for expensive equipment. The methods selected were to sublime disperse dyes into the tape, both with and without the fuming of cyanoacrylate, everywhere except for where the fingerprint was applied. The resulting color contrasts provided enough differentiation to visualize fingerprints on plastic tape under ambient light. Sequential fuming with cyanoacrylate followed by disperse dyes provided the best visualizations on all tapes, and cyanoacrylate followed by disperse yellow 211 clearly visualized fingerprints on black electrical tape.

  17. Design and fabrication of gecko-inspired adhesives.

    PubMed

    Jin, Kejia; Tian, Yu; Erickson, Jeffrey S; Puthoff, Jonathan; Autumn, Kellar; Pesika, Noshir S

    2012-04-03

    Recently, there has been significant interest in developing dry adhesives mimicking the gecko adhesive system, which offers several advantages compared to conventional pressure-sensitive adhesives. Specifically, gecko adhesive pads have anisotropic adhesion properties; the adhesive pads (spatulae) stick strongly when sheared in one direction but are non-adherent when sheared in the opposite direction. This anisotropy property is attributed to the complex topography of the array of fine tilted and curved columnar structures (setae) that bear the spatulae. In this study, we present an easy, scalable method, relying on conventional and unconventional techniques, to incorporate tilt in the fabrication of synthetic polymer-based dry adhesives mimicking the gecko adhesive system, which provides anisotropic adhesion properties. We measured the anisotropic adhesion and friction properties of samples with various tilt angles to test the validity of a nanoscale tape-peeling model of spatular function. Consistent with the peel zone model, samples with lower tilt angles yielded larger adhesion forces. The tribological properties of the synthetic arrays were highly anisotropic, reminiscent of the frictional adhesion behavior of gecko setal arrays. When a 60° tilt sample was actuated in the gripping direction, a static adhesion strength of ~1.4 N/cm(2) and a static friction strength of ~5.4 N/cm(2) were obtained. In contrast, when the dry adhesive was actuated in the releasing direction, we measured an initial repulsive normal force and negligible friction.

  18. NASA Global Atmospheric Sampling Program (GASP). Data report for tape VL0001. [data management and data retrieval of information from environmental surveys

    NASA Technical Reports Server (NTRS)

    Holdeman, J. D.; Lezberg, E. A.

    1976-01-01

    Atmospheric trace constituents in the upper troposphere and lower stratosphere are now being measured as part of the NASA Global Atmospheric Sampling Program (GASP), using fully automated air sampling systems on board commercial 747 aircraft in routine airline service. Measurements of atmospheric ozone and related meteorological and flight information obtained during several GASP flights in March 1975 are now available from the National Climatic Center, Asheville, North Carolina. In addition to the data from the aircraft, tropopause pressure data obtained from the National Meteorological Center (NMC) archives for the dates of the flights are included. This report is the first of a series of reports which describes the data currently available from GASP, including flight routes and dates, instrumentation, the data processing procedure used, and data tape specifications.

  19. Tape transport mechanism

    DOEpatents

    Groh, Edward F.; McDowell, William; Modjeski, Norbert S.; Keefe, Donald J.; Groer, Peter

    1979-01-01

    A device is provided for transporting, in a stepwise manner, tape between a feed reel and takeup reel. An indexer moves across the normal path of the tape displacing it while the tape on the takeup reel side of the indexer is braked. After displacement, the takeup reel takes up the displaced tape while the tape on the feed reel side of the indexer is braked, providing stepwise tape transport in precise intervals determined by the amount of displacement caused by the indexer.

  20. NASA Global Atmospheric Sampling Program (GASP) data report for tape VL0015, VL0016, VL0017, VL0018, VL0019, and VL0020

    NASA Technical Reports Server (NTRS)

    Papthakos, L. C.; Briehl, D.

    1981-01-01

    This is the twelfth of a series of reports which describes the data currently available from GASP, including flight routes and dates, instrumentation, data processing procedures, and data tape specifications. In-situ measurements of atmospheric ozone, cabin ozone, carbon monoxide, water vapor, particles, clouds, condensation nuclei, filter samples and related meteorological and flight information obtained during 1732 flights of aircraft N533PA, N4711U, N655PA, and VH-EBE from January 5, 1978 through October 9, 1978 are reported. These data are now available from the National Climatic Center, Asheville, NC, 22801. In addition to the GASP data, tropopause pressures obtained from time ans space interpolation of National Meteorological Center archived data for the dates of the flights are included.

  1. Recovery of recordings from heat damaged magnetic tapes

    NASA Technical Reports Server (NTRS)

    Melugin, J. F.; Obrien, D. E., III

    1973-01-01

    Damaged tapes can now be repaired at home as long as damage does not extend to layer-to-layer adhesion within tape roll. Splice repaired section into good roll or cassette for copying. Every effort should be made to complete copying on first run, because fidelity in repaired section deteriorates with each repetition.

  2. Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar

    NASA Technical Reports Server (NTRS)

    Gaier, James R.; Siamidis, John; Larkin, Elizabeth M.G.

    2008-01-01

    A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10-8 Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust stimulant processing capabilities: heating and cooling while stirring in order to degas and remove absorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions, and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples

  3. Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar

    NASA Technical Reports Server (NTRS)

    Gaier, James R.; Siamidis, John; Larkin, Elizabeth M. G.

    2010-01-01

    A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10(exp -8) Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust simulant processing capabilities: heating and cooling while stirring in order to degas and remove adsorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples.

  4. Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar

    NASA Technical Reports Server (NTRS)

    Gaier, James R.; Siamidis, John; Larkin, Elizabeth M. G.

    2008-01-01

    A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10(exp -8) Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust simulant processing capabilities: heating and cooling while stirring in order to degas and remove adsorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples.

  5. Accuracy testing of steel and electric groundwater-level measuring tapes: Test method and in-service tape accuracy

    USGS Publications Warehouse

    Fulford, Janice M.; Clayton, Christopher S.

    2015-10-09

    The calibration device and proposed method were used to calibrate a sample of in-service USGS steel and electric groundwater tapes. The sample of in-service groundwater steel tapes were in relatively good condition. All steel tapes, except one, were accurate to ±0.01 ft per 100 ft over their entire length. One steel tape, which had obvious damage in the first hundred feet, was marginally outside the accuracy of ±0.01 ft per 100 ft by 0.001 ft. The sample of in-service groundwater-level electric tapes were in a range of conditions—from like new, with cosmetic damage, to nonfunctional. The in-service electric tapes did not meet the USGS accuracy recommendation of ±0.01 ft. In-service electric tapes, except for the nonfunctional tape, were accurate to about ±0.03 ft per 100 ft. A comparison of new with in-service electric tapes found that steel-core electric tapes maintained their length and accuracy better than electric tapes without a steel core. The in-service steel tapes could be used as is and achieve USGS accuracy recommendations for groundwater-level measurements. The in-service electric tapes require tape corrections to achieve USGS accuracy recommendations for groundwater-level measurement.

  6. Magnetic tape user guide

    NASA Technical Reports Server (NTRS)

    Evans, A. B.; Lee, L. L.

    1985-01-01

    This User Guide provides a general introduction to the structure, use, and handling of magnetic tapes at Langley Research Center (LaRC). The topics covered are tape terminology, physical characteristics, error prevention and detection, and creating, using, and maintaining tapes. Supplementary documentation is referenced where it might be helpful. The documentation is included for the tape utility programs, BLOCK, UNBLOCK, and TAPEDMP, which are available at the Central Scientific Computing Complex at LaRC.

  7. Tape reading fixture

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Commercially available roller type desk pad provides an efficient and orderly manner of handling rolled paper tapes for proofreading. The fixture, which is modified to accept Flex-O-Writer or similar tapes and roll them in either direction, reduces the chance of damaging or soiling the tapes through repeated handling.

  8. Design and fabrication of polymer based dry adhesives inspired by the gecko adhesive system

    NASA Astrophysics Data System (ADS)

    Jin, Kejia

    There has been significant interest in developing dry adhesives mimicking the gecko adhesive system, which offers several advantages compared to conventional pressure sensitive adhesives. Specifically, gecko adhesive pads have anisotropic adhesion properties: the adhesive pads (spatulae) stick strongly when sheared in one direction but are non-adherent when sheared in the opposite direction. This anisotropy property is attributed to the complex topography of the array of fine tilted and curved columnar structures (setae) that bear the spatulae. In this thesis, easy, scalable methods, relying on conventional and unconventional techniques are presented to incorporate tilt in the fabrication of synthetic polymer-based dry adhesives mimicking the gecko adhesive system, which provide anisotropic adhesion properties. In the first part of the study, the anisotropic adhesion and friction properties of samples with various tilt angles to test the validity of a nanoscale tape-peeling model of spatular function are measured. Consistent with the Peel Zone model, samples with lower tilt angles yielded larger adhesion forces. Contact mechanics of the synthetic array were highly anisotropic, consistent with the frictional adhesion model and gecko-like. Based on the original design, a new design of gecko-like dry adhesives was developed which showed superior tribological properties and furthermore showed anisotropic adhesive properties without the need for tilt in the structures. These adhesives can be used to reversibly suspend weights from vertical surfaces (e.g., walls) and, for the first time to our knowledge, horizontal surfaces (e.g., ceilings) by simultaneously and judiciously activating anisotropic friction and adhesion forces. Furthermore, adhesion properties between artificial gecko-inspired dry adhesives and rough substrates with varying roughness are studied. The results suggest that both adhesion and friction forces on a rough substrate depends significantly on the

  9. VLBA: Formatter to Tape

    NASA Astrophysics Data System (ADS)

    Rogers, A. E. E. R.

    Introduction; Why Magnetic Tape?; VLBI Recording Systems; The VLBA Data Format; Longitudinal Format; Transverse Track Format; Data and Non-Data Replacement; Track Width and Track Structure; The VLBA Formatter; Switch Board; Header Control Board; Transport Driver Board; Timing and Control Board; DataBuffer Board; Analysis Board; Magnetic Recording Fundamentals; Recording Losses; Wavelength Response; Head-to-Tape Contact and Tribology; The VLBA Recorder; The Tape Transport; The Headstack; The Headstack Positioner; Control Electronics; Signal Electronics and Eye Pattern; Characteristics and Limitations; Error Rate Versus Bit Density; Tape Thickness Interchange; Head Flying; Overwrite; Tracking Errors; Headlife and Humidity; Thin Tape and Edge Damage by Frictional Heating; Tape Reel and Shipping Canister; Future VLBI Recording Systems; Expansion Paths for the VLBA Formatter; Recorder Improvements; Thinner Tape; Higher Data Rates; Next Generation of Heads; Mark IV; Summary and Conclusions

  10. Thermoplastic tape compaction device

    DOEpatents

    Campbell, V.W.

    1994-12-27

    A device is disclosed for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite. 5 figures.

  11. Thermoplastic tape compaction device

    DOEpatents

    Campbell, Vincent W.

    1994-01-01

    A device for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite.

  12. ERTS wideband tape recorder

    NASA Technical Reports Server (NTRS)

    Hayes, J. M.

    1973-01-01

    The ERTS video bandwith tape recorder uses a rotary head to run the tape in transverse mode; the head wheel gives a head-to-tape surface speed of nearly 5080 centimeter per second. The electronics unit handles 15 megabit per second rate with a bit-error rate of 0.00001. An operational unit onboard ERTS A returned images from the 85 to 90 percent of the earth that are not available in real time.

  13. Magnetic Tape Care, Storage, and Error Recovery.

    ERIC Educational Resources Information Center

    Schenck, Thomas

    1984-01-01

    Explains format of data on magnetic tape and process of reading and writing data to tape, and discusses sources of tape errors (physically damaged tape, unclean tape, magnetic alteration of data on tape, unclean or defective tape drive); correcting and/or bypassing tape errors; and care, storage, and shipment of tapes. (EJS)

  14. Carbon Nanotube-Based Synthetic Gecko Tapes

    NASA Astrophysics Data System (ADS)

    Dhinojwala, Ali

    2008-03-01

    Wall-climbing geckos have unique ability to attach to different surfaces without the use of any viscoelastic glues. On coming in contact with any surface, the micron-size gecko foot-hairs deform, enabling molecular contact over large areas, thus translating weak van der Waals (vdW) interactions into enormous shear forces. We will present our recent results on the development of synthetic gecko tape using aligned carbon nanotubes to mimic the keratin hairs found on gecko feet. The patterned carbon nanotube-based gecko tape can support a shear stress (36 N/cm^2) nearly four times higher than the gecko foot and sticks to a variety of surfaces, including Teflon. Both the micron-size setae (replicated by nanotube bundles) and nanometer-size spatulas (individual nanotubes) are necessary to achieve macroscopic shear adhesion and to translate the weak vdW interactions into high shear forces. The carbon nanotube based tape offers an excellent synthetic option as a dry conductive reversible adhesive in microelectronics, robotics and space applications. The mechanism behind these large shear forces and self-cleaning properties of these carbon nanotube based synthetic gecko tapes will be discussed. This work was performed in collaboration with graduate students Liehui Ge, and Sunny Sethi, and collaborators from RPI; Lijie Ci and Professor Pulickel Ajayan.

  15. Caught (Unfortunately) on Tape

    ERIC Educational Resources Information Center

    Young, Jeffrey R.

    2009-01-01

    Recording class sessions so students can view them online is becoming routine on many campuses. But all that taping can lead to "uh-oh moments," such as when a professor's joke about the college dean ends up on YouTube, or a private comment to a student after class is inadvertently broadcast. Some lecture bloopers caught on tape are…

  16. Kinematics of Tape Recording.

    ERIC Educational Resources Information Center

    Coleman, J. J.

    1982-01-01

    Describes mathematics of the nonliner relationships between a constant-speed, capstan-driven magnetic tape transport mechanism and a constant-angular-velocity take-up reel. The relationship, derived from the sum of a partial, serves in recognition of a finite tape. Thickness can serve as an example of rotational kinematics. (Author/SK)

  17. Kinesiology tape does not facilitate muscle performance: A deceptive controlled trial.

    PubMed

    Poon, K Y; Li, S M; Roper, M G; Wong, M K M; Wong, O; Cheung, R T H

    2015-02-01

    Kinesiology tape (KinTape) is a therapeutic tape without much understanding of its mechanism. KinTape claims to increase cutaneous stimulation, which facilitates motor unit firing, and consequently improves functional performance; however these, benefits could be due to placebo effects. This study investigated the true effects of KinTape by a deceptive, randomized, and controlled trial. Thirty healthy participants performed isokinetic testing of three taping conditions: true facilitative KinTape, sham KinTape, and no KinTape. The participants were blindfolded during the evaluation. Under the pretense of applying adhesive muscle sensors, KinTape was applied to their quadriceps in the first two conditions. Normalized peak torque, normalized total work, and time to peak torque were measured at two angular speeds (60°/s and 180°/s) and analyzed with one-way repeated measures ANOVA. Participants were successfully deceived and they were ignorant about KinTape. No significant differences were found between normalized peak torque, normalized total work, and time to peak torque at 60°/s or 180°/s (p = 0.31-0.99) between three taping conditions. The results showed that KinTape did not facilitate muscle performance in generating higher peak torque, yielding a greater total work, or inducing an earlier onset of peak torque. These findings suggest that previously reported muscle facilitatory effects using KinTape may be attributed to placebo effects.

  18. Effect of Water-Glass Coating on HA and HA-TCP Samples for MSCs Adhesion, Proliferation, and Differentiation

    PubMed Central

    Bajpai, Indu; Kim, Duk Yeon; Kyong-Jin, Jung; Song, In-Hwan

    2016-01-01

    Ca-P and silicon based materials have become very popular as bone tissue engineering materials. In this study, water-glass (also known as sodium silicate glass) was coated on sintered hydroxyapatite (HA) and HA-TCP (TCP stands for tricalcium phosphate) samples and subsequently heat-treated at 600°C for 2 hrs. X-rays diffraction showed the presence of β- and α-TCP phases along with HA in the HA-TCP samples. Samples without coating, with water-glass coating, and heat-treated after water-glass coating were used to observe the adhesion and proliferation response of bone marrow derived-mesenchymal stem cells (MSCs). Cell culture was carried out for 4 hrs, 1 day, and 7 days. Interestingly, all samples showed similar response for cell adhesion and proliferation up to 7-day culture but fibronectin, E-cadherin, and osteogenic differentiation related genes (osteocalcin and osteopontin) were significantly induced in heat-treated water-glass coated HA-TCP samples. A water-glass coating on Ca-P samples was not found to influence the cell proliferation response significantly but activated some extracellular matrix genes and induced osteogenic differentiation in the MSCs. PMID:27429988

  19. Investigation of adhesion of functional nanolayers to different substrates

    NASA Astrophysics Data System (ADS)

    Krzemiński, J.; Skalski, A.; Szałapak, J.; Jakubowska, M.

    2016-09-01

    The adhesion test are used in almost any industry. There are many different techniques and tools from scotch tape test to nanoscratch machine. The common test is pull-off test. Authors design the module for the testing machine and presented the researches about the adhesion of spray coated nanosilver layers to different substrates. In the article the main technique problems are discussed. Authors shows the typical graph result and described the separated sections. The experimental model was made and checked. The breaking forces of glass, Kapton and Aluminium samples are presented on the graph and discussed.

  20. Stratum Corneum Tape Stripping: Monitoring of Inflammatory Mediators in Atopic Dermatitis Patients Using Topical Therapy

    PubMed Central

    Koppes, Sjors A.; Brans, Richard; Ljubojevic Hadzavdic, Suzana; Frings-Dresen, Monique H.W.; Rustemeyer, Thomas; Kezic, Sanja

    2016-01-01

    Objective The aim of this study was to explore the tape strip sampling technique in the assessment of stratum corneum levels of inflammatory mediators in a clinical trial setting. Methods Thirty-eight inflammatory mediators were analyzed by a multiplex-assay in the stratum corneum, collected by adhesive tapes before and after 6 weeks of therapy, in mild and moderate atopic dermatitis (AD) patients (n = 90). Treatment was a ceramide- and magnesium-containing emollient. Results Twenty-four mediators could quantitatively be determined. The Th2 mediators interleukin (IL)-4, IL-13, CCL2 (monocyte chemotactic protein-1), CCL22 (macrophage-derived chemokine), and CCL17 [thymus and activation-regulated chemokine (TARC)] were significantly decreased after therapy as well as IL-1β, IL-2, IL-8 (CXCL8), IL-10, acute-phase protein serum amyloid A, C-reactive protein, and vascular adhesion molecule-1. The decrease of CCL17 and IL-8 was correlated with the decrease in disease severity in a subgroup of moderate AD individuals. Conclusion Stratum corneum tape stripping offers a minimally invasive approach for studying local levels of immunomodulatory molecules in the skin. CCL17 (TARC) and IL-8 were found to be the most promising biomarkers of AD and might be useful for investigating the course of skin diseases and the effect of local therapy. PMID:27584583

  1. PHOTOELECTRIC CONTROL FOR TAPE POSITIONING

    DOEpatents

    Woody, J.W. Jr.

    1961-07-25

    A control system is described for producing control impulses which may be used to start, stop, and position a magnetic tape with respect to a transducer, and to locate discrete areas on the tape. Means are provided for positive identification of data blocks, exact positioning of the tape under the magnetic head, drive in either direction, accurate skip-over of imperfect regions of the tape, stopping the tape if equipment malfunction results in a failure to detect the block-identifying signals, and starting and stopping those parts of the tape between of the tape drive clutches.

  2. Adhesive Contact Sweeper

    NASA Technical Reports Server (NTRS)

    Patterson, Jonathan D.

    1993-01-01

    Adhesive contact sweeper removes hair and particles vacuum cleaner leaves behind, without stirring up dust. Also cleans loose rugs. Sweeper holds commercially available spools of inverted adhesive tape. Suitable for use in environments in which air kept free of dust; optics laboratories, computer rooms, and areas inhabited by people allergic to dust. For carpets, best used in tandem with vacuum cleaner; first pass with vacuum cleaner removes coarse particles, and second pass with sweeper extracts fine particles. This practice extends useful life of adhesive spools.

  3. Using nanostructured conductive carbon tape modified with bismuth as the disposable working electrode for stripping analysis in paper-based analytical devices.

    PubMed

    Feng, Qiu-Mei; Zhang, Qing; Shi, Chuan-Guo; Xu, Jing-Juan; Bao, Ning; Gu, Hai-Ying

    2013-10-15

    Low cost disposable working electrodes are specifically desired for practical applications of electrochemical detection considering maturity of electrochemical stations and data collection protocols. In this paper double-sided conductive adhesive carbon tape with nanostructure was applied to fabricate disposable working electrodes. Being supported by indium tin oxide glass, the prepared carbon tape electrodes were coated with bismuth film for stripping analysis of heavy metal ions. By integrating the bismuth modified electrodes with paper-based analytical devices, we were able to differentiate Zn, Cd and Pb ions with the sample volume of around 15 μL. After the optimization of parameters, including modification of bismuth film and the area of the electrodes, etc., Pb ions could be measured in the linear range from 10 to 500 μg/L with the detection limit of 2 μg/L. Our experimental results revealed that the disposable modified electrodes could be used to quantify migrated lead from toys with the results agreed well with that using atomic absorption spectrometry. Although bismuth modification and stripping analysis could be influenced by the low conductivity of the carbon tape, the low cost disposable carbon tape electrodes take the advantages of large-scaled produced double-sided carbon tape, including its reproducible nanostructure and scaled-up fabrication process. In addition, the preparation of disposable electrodes avoids time-consuming pretreatment and experienced operation. This study implied that the carbon tape might be an alternative candidate for practical applications of electrochemical detection.

  4. Aligned Carbon Nanotube Tape for Sensor Applications

    NASA Technical Reports Server (NTRS)

    Tucker, Dennis S.

    2013-01-01

    For this effort, will concentrate on three applications: Vibration Gyroscope utilizes piezoelectric properties of the tape and Coriolis effect Accelerometer utilizes the piezoresistive property Strain Gauge utilizes piezoresistive property Accelerometer and Strain Gauge can also utilize piezoelectric effect Test piezoelectric properties using facilities at the Microfabrication Laboratory (AMRDEC) . Enhance piezoelectric effect using polyvinylidine fluoride and P(VDF ]TrFE) which is readily polarizable .Spray matrix solution while winding fiber; Sandwich of CNT tape and PVDF film (DOE .Two Level) . Construct and test prototype vibration gyroscope . Construct and test prototype accelerometer using cantilever design . Test strain sensitivity of CNT tape against industrial strain gauge . Embed CNT tape in composite samples as well as on surface and test to failure (4 ]point bend) A piezoelectric device exhibits an electrical response from a mechanical applied stress. . A piezoelectric device has both capacitance and resistance properties in which by applying an electric field from a waveform will exert a mechanical stress that can be monitored for a response. . The typical waveform applied is a sinusoidal waveform of a defined voltage for a defined period. The defined voltage is driven from 0 volts to the positive defined volts then back to 0 and driven to negative defined volts then back to 0. . Example. Vmax set to 10V and period set to 10 ms. . Voltage will start at zero, go to 10 volts, return to zero, go to ]10 volts and return to zero during 10 ms. . Applying this electrical field to a DUT, the capacitance response and resistance response can be observed. CNT tape is easier to manufacture and cheaper than micromachining silicon or other ceramic piezoelectric used in gyroscopes and accelerometers CNT tape properties can be modified during manufacture for specific application CNT tape has enhanced mechanical and thermal properties in addition to unique electrical

  5. Performance of thermal control tape in the protection of composite materials to space environmental exposure

    NASA Technical Reports Server (NTRS)

    Kamenetzky, R. R.; Whitaker, A. F.

    1992-01-01

    Thermal control tape flown on the Long Duration Exposure Facility (LDEF) experiment A0171 has shown to be effective in protecting epoxy fiberglass composites from atomic oxygen and ultraviolet degradation. The tape adhesive performed well. The aluminum, however, appeared to have become embrittled by the 5.8 years of space radiation exposure.

  6. The Carbon Monoxide Tape Recorder

    NASA Technical Reports Server (NTRS)

    Schoeberl, M. R.; Duncan, B. N.; Douglass, A. R.; Waters, J.; Livesey, N.; Read, W.; Filipiak, M.

    2006-01-01

    Using Aura MLS data we have identified the stratospheric tape recorder in carbon monoxide (CO). Unlike the water vapor tape recorder, which is controlled by upper troposphere processes, the CO tape recorder is linked to seasonal biomass burning. Since CO has a lifetime of only a few months, the CO tape recorder barely extends above 20 km. The tape head for CO appears to be close to 360K near the same location as the water vapor tape head [Read et al, 20041. Both tape heads are below the equatorial cold point tropopause but above the base of the tropical tropopause layer. The tape recorder signal becomes more distinct from 360K to 380K suggesting that convective detrainment of plays a decreasingly important role with altitude. The Global Modeling Initiative chemical transport model forced by the climatology of biomass burning reproduces the CO tape recorder.

  7. Aluminum Tape Evaluation for Sealable Aluminum Tubes Containing Mark 22 Fuel Tubes

    SciTech Connect

    RHODES, WILLIAM

    2003-01-01

    As part of the HEU Blend Down project, aluminum tape is required to seal aluminum tubes that will hold contaminated Mark 22 fuel tubes for dissolution. From a large field of candidate tapes, Avery Dennison's Fasson 0802 tape (synthetic rubber adhesive system) was found to be acceptable for this application. This tape will disentangle in the normal H-Canyon dissolver solution and have no detrimental effect on the H-Canyon process. Upon placement of Fasson 0802 tape into the dissolver solution, nitric acid will attack and disentangle the block copolymer network and destroy the adhesive nature of the material, resulting in insoluble particles that can be removed via centrifuge operations (cake weight increase of no more than 1 percent). The addition of the tape will not generate off-gas products and the resultant solution characteristics (surface tension, viscosity, density, and disengagement time) will be unaffected. Further, the potential effect on the down-stream evaporation system is negligible. Since the tape will not be placed in a high radiation environment, radiation stability is not an issue. Through detailed discussions with Avery Dennison chemists and based on analytical tests, a fairly detailed understanding of the constituents comprising the proprietary adhesive system has been assembled. Most importantly, chlorine was not detected in the aluminum tape (neutron activation analysis detection limit is 16 ppm). Finally, application of this tape will not impact LEU specifications.

  8. Surface Contamination of Adhesive Bonding Materials.

    DTIC Science & Technology

    1979-12-01

    test is illustrated in Figure 19. The specimen is then exposed to some environment such as high temperature and humidity and monitored for crack growth...bonded and subsequently failed at high humidity and elevated temperatures indicate early crack propagation at the adhesive-oxide interface. Large...Adhesive Tape (A) and a Point Not Exposed to the Tape (B) 21 Positive Secondary Ion Mass Spectra from 44 6AI-4V-Ti at Room Temperature (156-1) and after

  9. Certification of ICI 1012 optical data storage tape

    NASA Technical Reports Server (NTRS)

    Howell, J. M.

    1993-01-01

    ICI has developed a unique and novel method of certifying a Terabyte optical tape. The tape quality is guaranteed as a statistical upper limit on the probability of uncorrectable errors. This is called the Corrected Byte Error Rate or CBER. We developed this probabilistic method because of two reasons why error rate cannot be measured directly. Firstly, written data is indelible, so one cannot employ write/read tests such as used for magnetic tape. Secondly, the anticipated error rates need impractically large samples to measure accurately. For example, a rate of 1E-12 implies only one byte in error per tape. The archivability of ICI 1012 Data Storage Tape in general is well characterized and understood. Nevertheless, customers expect performance guarantees to be supported by test results on individual tapes. In particular, they need assurance that data is retrievable after decades in archive. This paper describes the mathematical basis, measurement apparatus and applicability of the certification method.

  10. Tape Dump and Restore.

    DTIC Science & Technology

    1980-08-28

    VM/ CMS as provided at Virginia Tech and to make it possible to transfer files from this system to other computer systems , possibly machines using the...Technical Memorandum No. 80-5 DTI(-C August 28, 1980 DEC T.77w S DEC23 1980 F ABSTRACT A set of three programs to write CMS disk files on magnetic...tape in a variety of formats suitable for reading on a variety of computing systems and for restoring these tape files to disk within the restrictions

  11. Safety brake for tape reels

    NASA Technical Reports Server (NTRS)

    Carle, C. E.

    1977-01-01

    All-mechanical device senses end of tape and stops reel, even in event of electronic system failure. Assembly includes stop to prevent brake from overriding tape. Recentering mechanism returns brake to neutral position after torque is removed from reels.

  12. Adhesion in ceramics and magnetic media

    NASA Technical Reports Server (NTRS)

    Miyoshi, Kazuhisa

    1989-01-01

    When a ceramic is brought into contact with a metal or a polymeric material such as a magnetic medium, strong bonds form between the materials. For ceramic-to-metal contacts, adhesion and friction are strongly dependent on the ductility of the metals. Hardness of metals plays a much more important role in adhesion and friction than does the surface energy of metals. Adhesion, friction, surface energy, and hardness of a metal are all related to its Young's modulus and shear modulus, which have a marked dependence on the electron configuration of the metal. An increase in shear modulus results in a decrease in area of contact that is greater than the corresponding increase in surface energy (the fond energy) with shear modulus. Consequently, the adhesion and friction decrease with increasing shear modulus. For ceramics in contact with polymeric magnetic tapes, environment is extremely important. For example, a nitrogen environment reduces adhesion and friction when ferrite contacts polymeric tape, whereas a vacuum environment strengthens the ferrite-to-tape adhesion and increases friction. Adhesion and friction are strongly dependent on the particle loading of the tape. An increase in magnetic particle concentration increases the complex modulus of the tape, and a lower real area of contact and lower friction result.

  13. Automated Tape Laying Machine for Composite Structures.

    DTIC Science & Technology

    The invention comprises an automated tape laying machine, for laying tape on a composite structure. The tape laying machine has a tape laying head...neatly cut. The automated tape laying device utilizes narrow width tape to increase machine flexibility and reduce wastage.

  14. Rapid prototyping of microfluidic systems using a PDMS/polymer tape composite.

    PubMed

    Kim, Jungkyu; Surapaneni, Rajesh; Gale, Bruce K

    2009-05-07

    Rapid prototyping of microfluidic systems using a combination of double-sided tape and PDMS (polydimethylsiloxane) is introduced. PDMS is typically difficult to bond using adhesive tapes due to its hydrophobic nature and low surface energy. For this reason, PDMS is not compatible with the xurography method, which uses a knife plotter and various adhesive coated polymer tapes. To solve these problems, a PDMS/tape composite was developed and demonstrated in microfluidic applications. The PDMS/tape composite was created by spinning it to make a thin layer of PDMS over double-sided tape. Then the PDMS/tape composite was patterned to create channels using xurography, and bonded to a PDMS slab. After removing the backing paper from the tape, a complete microfluidic system could be created by placing the construct onto nearly any substrate; including glass, plastic or metal-coated glass/silicon substrates. The bond strength was shown to be sufficient for the pressures that occur in typical microfluidic channels used for chemical or biological analysis. This method was demonstrated in three applications: standard microfluidic channels and reactors, a microfluidic system with an integrated membrane, and an electrochemical biosensor. The PDMS/tape composite rapid prototyping technique provides a fast and cost effective fabrication method and can provide easy integration of microfluidic channels with sensors and other components without the need for a cleanroom facility.

  15. A new approach to ELISA-based anti-glycolipid antibody evaluation of highly adhesive serum samples

    PubMed Central

    Usuki, Seigo; O’Brien, Dawn; Rivner, Michael H.; Yu, Robert K.

    2014-01-01

    The enzyme-linked immunosorbent assay (ELISA) is a standard immunoassay used in measuring antibody reactivity (expressed as titers) for glycosphingolipids (GSLs) such as gangliosides and sulfoglycolipids in the sera of patients with Guillain-Barré syndrome (GBS), variants of GBS, and chronic inflammatory demyelinating polyneuropathy (CIDP). In the present study, anti-GSL antibodies were evaluated using a new formula of affinity parametric complex (APC), calculated from limiting-dilution serum assay data, followed by affinity parametric complex criterion (APCC). Using assay results based on APCC, we analyzed serum samples categorized into acute inflammatory demyelinating polyneuropathy (AIDP), acute motor-sensory axonal neuropathy (AMSAN), CIDP, CIDP with Myasthenia Gravis (MG), and Amyotrophic Lateral Sclerosis (ALS). We were able to determine the affinity strength of antibodies otherwise hidden in the non-specific background activity in highly adhesive serum samples. The thin-layer chromatography (TLC)-immuno-overlay method assured us that this new method is an accurate and reliable way for evaluating anti-GSL antibodies using ELISA serum sample data. PMID:24861939

  16. Conductive carbon tape used for support and mounting of both whole animal and fragile heat-treated tissue sections for MALDI MS imaging and quantitation.

    PubMed

    Goodwin, Richard J A; Nilsson, Anna; Borg, Daniel; Langridge-Smith, Pat R R; Harrison, David J; Mackay, C Logan; Iverson, Suzanne L; Andrén, Per E

    2012-08-30

    Analysis of whole animal tissue sections by MALDI MS imaging (MSI) requires effective sample collection and transfer methods to allow the highest quality of in situ analysis of small or hard to dissect tissues. We report on the use of double-sided adhesive conductive carbon tape during whole adult rat tissue sectioning of carboxymethyl cellulose (CMC) embedded animals, with samples mounted onto large format conductive glass and conductive plastic MALDI targets, enabling MSI analysis to be performed on both TOF and FT-ICR MALDI mass spectrometers. We show that mounting does not unduly affect small molecule MSI detection by analyzing tiotropium abundance and distribution in rat lung tissues, with direct on-tissue quantitation achieved. Significantly, we use the adhesive tape to provide support to embedded delicate heat-stabilized tissues, enabling sectioning and mounting to be performed that maintained tissue integrity on samples that had previously been impossible to adequately prepare section for MSI analysis. The mapping of larger peptidomic molecules was not hindered by tape mounting samples and we demonstrate this by mapping the distribution of PEP-19 in both native and heat-stabilized rat brains. Furthermore, we show that without heat stabilization PEP-19 degradation fragments can detected and identified directly by MALDI MSI analysis.

  17. Tape Placement Head for Applying Thermoplastic Tape to an Object

    NASA Technical Reports Server (NTRS)

    Cope, Ralph D. (Inventor); Funck, Steve B. (Inventor); Gruber, Mark B. (Inventor); Lamontia, Mark A. (Inventor); Johnson, Anthony D. (Inventor)

    2008-01-01

    A tape placement head for applying thermoplastic tape to an object includes a heated feeder which guides the tape/tow to a heated zone. The heated zone has a line compactor having a single row of at least one movable heated member. An area compactor is located in the heated zone downstream from the line compactor. The area compactor includes a plurality of rows of movable feet which are extendable toward the tape/tow different distances with respect to each other to conform to the shape of the object. A shim is located between the heated compactors and the tape/tow. A chilled compactor is in a chilled zone downstream from the heated zone. The chilled zone includes a line chilled compactor and an area chilled compactor. A chilled shim is mounted between the chilled compactor and the tape/tow.

  18. A non-collinear mixing technique to measure the acoustic nonlinearity parameter of an adhesive bond from one side of the sample

    NASA Astrophysics Data System (ADS)

    Ju, Taeho; Achenbach, Jan D.; Jacobs, Laurence J.; Qu, Jianmin

    2017-02-01

    In this study, we developed a non-collinear mixing technique to measure the Acoustic Nonlinearity Parameter (ANLP) of adhesive bonds. One of the most significant features of the new method is that it requires only one-side access to the adhesive bond being measured, which significantly increases its utility in field measurements. To demonstrate the effectiveness of the newly developed technique, an adhesively jointed aluminum sample was measured with different thermal aging times, using the non-collinear mixing technique with a longitudinal and a shear wave as incident waves to obtain the ANLP of the adhesive bond. The measured results clearly show that the ANLP varies with aging time. To verify that the signals received from the shear wave receiver are indeed the mixing wave, the finite element method was used to simulate the wave motion in the test sample. The simulation results clearly show that the signals recorded by the shear wave receiver are the desired mixing wave, whose amplitude is proportional to the ANLP of the adhesive bond.

  19. Magnetic tape lightning current detectors

    NASA Technical Reports Server (NTRS)

    Crouch, K. E.; Jafferis, W.

    1980-01-01

    Development and application tests of a low cost, passive, peak lightning current detector (LCD) found it to provide measurements with accuracies of + or - 5 percent to + or - 10 percent depending on the readout method employed. The LCD uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. The test results showed that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10 percent were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result.

  20. 7 CFR 2902.16 - Adhesive and mastic removers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Adhesive and mastic removers. 2902.16 Section 2902.16... Items § 2902.16 Adhesive and mastic removers. (a) Definition. Solvent products formulated for use in removing asbestos, carpet, and tile mastics as well as adhesive materials, including glue, tape, and...

  1. 7 CFR 2902.16 - Adhesive and mastic removers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 15 2011-01-01 2011-01-01 false Adhesive and mastic removers. 2902.16 Section 2902.16... Items § 2902.16 Adhesive and mastic removers. (a) Definition. Solvent products formulated for use in removing asbestos, carpet, and tile mastics as well as adhesive materials, including glue, tape, and...

  2. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, Eric B.; Muller, Albert C.

    1984-01-01

    A high voltage oil-impregnated electrical cable with fully polymer taped insulation operable to 765 kV. Biaxially oriented, specially processed, polyethylene, polybutene or polypropylene tape with an embossed pattern is wound in multiple layers over a conductive core with a permeable screen around the insulation. Conventional oil which closely matches the dielectric constant of the tape is used, and the cable can be impregnated after field installation because of its excellent impregnation characteristics.

  3. Pillows and Tape.

    PubMed

    Mand, Parandeep; Miller, Kevin M

    2010-03-09

    A 76-year-old man with a severe neck deformity resulting in a facedown posture presented with a visually significant cataract in his right eye. The patient had been scheduled for cataract surgery elsewhere, but the surgery was cancelled in the operating room when he could not be positioned beneath the operating microscope. The patient's surgery was safely and effectively performed by placing 25 to 30 pillows under his buttocks and legs and one pillow and a towel beneath his head and neck. The patient and pillows were taped to the operating table so that they would not move.

  4. Multifilamentary niobium tin superconductor tape

    NASA Technical Reports Server (NTRS)

    Brisbin, P. H.; Coles, W. D.

    1975-01-01

    In the method proposed for fabricating multifilamentary Nb3Sn tape, filamentary superconducting paths are produced in standard commercial superconductor tape by chemical milling of separator slots through the Nb3Sn layer. The multifilament configuration features a matrix of ten 1.2 mm wide parallel helical superconducting paths along the length of the tape. The paths are spaced 0.4 mm apart. Tapes tested as small pancake coils demonstrated the integrity and continuity of the matrix, and showed that critical current was sustained in direct proportion to retained superconductor.

  5. Tape casting of magnesium oxide.

    SciTech Connect

    Ayala, Alicia; Corral, Erica L.; Loehman, Ronald E.; Bencoe, Denise Nora; Reiterer, Markus; Shah, Raja A.

    2008-02-01

    A tape casting procedure for fabricating ceramic magnesium oxide tapes has been developed as a method to produce flat sheets of sintered MgO that are thin and porous. Thickness of single layer tapes is in the range of 200-400 {micro}m with corresponding surface roughness values in the range of 10-20 {micro}m as measured by laser profilometry. Development of the tape casting technique required optimization of pretreatment for the starting magnesium oxide (MgO) powder as well as a detailed study of the casting slurry preparation and subsequent heat treatments for sintering and final tape flattening. Milling time of the ceramic powder, plasticizer, and binder mixture was identified as a primary factor affecting surface morphology of the tapes. In general, longer milling times resulted in green tapes with a noticeably smoother surface. This work demonstrates that meticulous control of the entire tape casting operation is necessary to obtain high-quality MgO tapes.

  6. Tape Cassette Bacteria Detection System

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

  7. Wire and Packing Tape Sandwiches

    ERIC Educational Resources Information Center

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  8. ICI optical data storage tape

    NASA Technical Reports Server (NTRS)

    Mclean, Robert A.; Duffy, Joseph F.

    1991-01-01

    Optical data storage tape is now a commercial reality. The world's first successful development of a digital optical tape system is complete. This is based on the Creo 1003 optical tape recorder with ICI 1012 write-once optical tape media. Several other optical tape drive development programs are underway, including one using the IBM 3480 style cartridge at LaserTape Systems. In order to understand the significance and potential of this step change in recording technology, it is useful to review the historical progress of optical storage. This has been slow to encroach on magnetic storage, and has not made any serious dent on the world's mountains of paper and microfilm. Some of the reasons for this are the long time needed for applications developers, systems integrators, and end users to take advantage of the potential storage capacity; access time and data transfer rate have traditionally been too slow for high-performance applications; and optical disk media has been expensive compared with magnetic tape. ICI's strategy in response to these concerns was to concentrate its efforts on flexible optical media; in particular optical tape. The manufacturing achievements, media characteristics, and media lifetime of optical media are discussed.

  9. Book Selection from MARC Tapes.

    ERIC Educational Resources Information Center

    Wainwright, Jane; Hills, Jacqueline

    In April 1971 the Aslib Research and Development Department began a study on selective dissemination from MARC tapes. The aim of the project was to explore the technical and economic feasibility of providing selective notifications of current books, by extraction from MARC tapes, to specialized libraries. Typical of the potential customers…

  10. An improved magnetic tape recorder

    NASA Technical Reports Server (NTRS)

    Uber, P. W.

    1968-01-01

    Magnetic tape recorder employs a single capstan for simultaneously driving the supply and take-up reels in such a manner that the tape passing between the reels is kept under a predetermined constant tension. This recorder operates with little power and is sufficiently rugged to withstand the severe stresses encountered in high-altitude balloon flight tests.

  11. Sharpen Your Skills: Tape Recording.

    ERIC Educational Resources Information Center

    Perry, Helen

    1984-01-01

    Three short articles provide tape recording instructions for braille transcribers and teachers of the visually handicapped, for transcribing instructional materials. The first article gives instructions for creating a "mini" table of contents, or index, to be inserted at the beginning of each tape. The second article provides…

  12. Tape/head interface study

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Existing high energy tapes, high track density heads, and transport guidance techniques were evaluated and characterized to enable these technologies to be employed in future spacecraft recorders with high confidence. The results of these study efforts demonstrated tracking accuracy tape and head density that will support spacecraft recorders with data rates of a minimum of 150 Mbps and storage capacities ranging from 10 to the 10th to 10 to the 11th bits. Seven high energy tapes of either .25 in width, 1.00 in width, or both, were tested. All tapes were tested at the same speed (30 ips) and the same packing density (33 KBI). The performance of all 1 in tapes was considered superior.

  13. Clinical applications of polytetrafluoroethylene (PTFE) tape in restorative dentistry.

    PubMed

    Sattar, M M; Patel, M; Alani, A

    2017-02-10

    Restorative dental procedures are ever developing; one reason for this can be attributed to newer materials with better handling properties and our ability to manipulate them more effectively. As a result various techniques have been described to aid clinicians in obtaining predictable results in restorative dental procedures. This article aims to review the use of plumber's tape to assist in adhesive, endodontic and implant related dental procedures, when compared to other available materials.

  14. The ultratough peeling of elastic tapes from viscoelastic substrates

    NASA Astrophysics Data System (ADS)

    Afferrante, L.; Carbone, G.

    2016-11-01

    The peeling of an elastic thin tape from a flat smooth viscoelastic substrate is investigated. Based on a Green function approach and on the translational invariance, a closed form analytical solution is proposed, which takes into account the viscoelastic dissipation in the substrate material. We find that peeling is prevented from taking place, only when the external force is smaller than the one predicted by Kendall's formula for elastic tapes on rigid substrates. However, we also find that, regardless of the value of the applied force, steady state detachment may occur when the elastic tape is sufficiently stiff. In this case, the constant peeling velocity can be modulated by properly defining the geometrical parameters and the material properties of tape and viscoelastic foundation. On the other hand, for relatively high peeling angles or compliant tapes a threshold value of the peeling force is found, above which the steady-state equilibrium is no longer possible and unstable detachment occurs. The present study contributes to shed light on the behavior of pressure sensitive adhesives in contact with viscoelastic substrates like the human skin. At the same time, it can be considered a first step towards a better understanding of the effect of viscoelastic dissipation on the fracture behavior of solids.

  15. Noncontacting ultrasonic and electromagnetic HTS tape NDE

    SciTech Connect

    Telschow, K.L.; Bruneel, F.W.; Walter, J.B.; Koo, L.S.

    1996-10-01

    Two noncontacting nondestructive evaluation techniques (electromagnetic and ultrasonic) for inspection of high temperature superconducting tapes are described. Results for Ag-clad BSCCO tapes are given.

  16. Migration of odorous compounds from adhesives used in market samples of food packaging materials by chromatography olfactometry and mass spectrometry (GC-O-MS).

    PubMed

    Vera, Paula; Canellas, Elena; Nerín, Cristina

    2014-02-15

    Adhesives are commonly used in the manufacture of multilayer food packaging materials. Although they are not in direct contact with the packed food, their compounds may migrate from the adhesive through the substrates to the food. The aim of this work is to determine the migrant concentration in order to evaluate the possible human risk and also to determine if this migration could affect the organoleptic properties of packed food. For this purpose, a total of 12 market samples of multilayer materials (laminates) for packaging dry food (tomatoes, cakes, cookies, breadcrumbs, flour or salt) or fresh food (pizza and pastry) produced with 5 different adhesives were analysed by GC-O-MS. A total of 25 different compounds from adhesives were detected in these laminates. Seventy-six percentage of these compounds migrated into a dry food simulant (Tenax®). Furthermore, compounds with concentrations below the MS detection limit were detected by sniffers with a high modified frequency (MF%). Acetic acid, butyric acid and cyclohexanol with vinegar, cheese and camphor odours were the most abundant compounds. All migration data were below the specific migration limits (SML) and threshold toxicological concern (TTC) recommended values according to the Cramer classification.

  17. Variable diameter CO2 laser ring-cutting system adapted to a zoom microscope for applications on polymer tapes.

    PubMed

    Förster, Erik; Bohnert, Patrick; Kraus, Matthias; Kilper, Roland; Müller, Ute; Buchmann, Martin; Brunner, Robert

    2016-11-20

    This paper presents the conception and implementation of a variable diameter ring-cutting system for a CO2 laser with a working wavelength of 10.6 μm. The laser-cutting system is adapted to an observation zoom microscope for combined use and is applicable for the extraction of small circular areas from polymer films, such as forensic adhesive tapes in a single shot. As an important characteristic for our application, the variable diameter ring-cutting system provides telecentricity in the target area. Ring diameters are continuously tunable between 500 μm and 2 mm. A minimum width of less than 20 μm was found for the ring profile edge. The basic characteristics of the system, including telecentricity, were experimentally evaluated and demonstrated by cutting experiments on different polymer tapes and further exemplary samples.

  18. Canadian Contemporary Issues on Tape

    ERIC Educational Resources Information Center

    Shapter, Jean

    1974-01-01

    Four tapes with interviews with experts in the designated fields comprise the series: a) Canada's Foreign Relations, 1867-1919; b) Canada's Foreign Relations, 1919-1945; c) Canada and China, and d) Canadian Diplomacy and Foreign Policy. (JA)

  19. String and Sticky Tape Experiments.

    ERIC Educational Resources Information Center

    Edge, R. D., Ed.

    1979-01-01

    Explains how to demonstrate the fundamentals of one dimensional kinematics such as Newton's third law of motion, and collision between bodies, using simple materials of marbles, strings, sticky tape, drinking straws, and rubber bands. (GA)

  20. Recovery of DNA from latent fingerprint tape lifts archived against matte acetate.

    PubMed

    Steadman, Shelly A; Hoofer, Steven R; Geering, Sarah C; King, Stephanie; Bennett, Marc A

    2015-05-01

    This study was driven by court order to examine methods to remove, extract, and STR-type potential DNA entrapped between latent fingerprint lifting tape and matte acetate that was collected from a 1977 crime scene. Results indicate that recovery of appreciable quantities of DNA is more challenging once adhesive is attached to matte acetate cards and even more difficult when fixed following black powder enhancement. STR amplification of extracts from entrapped fingermarks collected following the dusting/lifting procedure did not produce robust profiles, and extraneous peaks not expressed by print donors were detected for some samples. A hearing was set to argue whether there was DNA remaining to be tested, and if so, whether that DNA could be exculpatory in this postconviction matter. The studies herein provided the basis for the court's decision to not require the testing.

  1. Casting Of Multilayer Ceramic Tapes

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr.

    1991-01-01

    Procedure for casting thin, multilayer ceramic membranes, commonly called tapes, involves centrifugal casting at accelerations of 1,800 to 2,000 times normal gravitational acceleration. Layers of tape cast one at a time on top of any previous layer or layers. Each layer cast from slurry of ground ceramic suspended in mixture of solvents, binders, and other components. Used in capacitors, fuel cells, and electrolytic separation of oxygen from air.

  2. Tape Storage Optimization at BNL

    NASA Astrophysics Data System (ADS)

    Yu, David; Lauret, Jérôme

    2011-12-01

    The BNL's RHIC and Atlas Computing Facility (RACF), is supporting the RHIC experiment as its Tier0 center and the Atlas/LHC as a Tier1 center. The RACF had to address the issue of efficient access to data stored to disk and tape storage. Randomly restoring files out of tapes destroys access performance to tape by causing too frequently, high latency and time consuming tape mount and dismount. BNL's mass storage system currently holds more than 16 PB of data on tapes, managed by HPSS. To restore files from HPSS, we make use of a scheduler software, called ERADAT. This scheduler system was originally based on a code from OakRidge National Lab, and then it was renamed to BNL Batch at 2005 after some major modifications and enhancements. The new BNL Batch, ERADAT, provides dynamic HPSS resource management, schedule jobs efficiently, enhanced visibility of real-time staging activities and advanced error handling, to maximize the tape staging performance. ERADAT is the interface between HPSS and other applications such as the DataCarousel, our home developed production system and dCache. Scalla/Xrootd MSS can also be interfaced with HPSS via DataCarousel. ERADAT has demonstrated great performance in BNL and other institute.

  3. Functional taping applied to upper limb of children with hemiplegic cerebral palsy: a pilot study.

    PubMed

    Mazzone, S; Serafini, A; Iosa, M; Aliberti, M N; Gobbetti, T; Paolucci, S; Morelli, D

    2011-12-01

    Functional taping with elastic bandages and adhesive tapes could limit the action of upper limb spastic muscles and sustain that of weaker muscles in children with hemiplegic cerebral palsy (CP). 16 young children with CP (3±2 years old) were enrolled in this pilot study including 5 months of taping in conjunction with conventional physical therapy, followed by 7 months of physical therapy alone (taping wash-out), and other 5 months of taping plus therapy. Large improvements in the Melbourne assessment score were found in the first period in which taping was used (+15.4%, p<0.001) and also in the second one despite 8 drop-outs (+8.4%, p=0.012), but not during the taping wash-out (- 4.6%; p=0.093). These results suggest that children with CP could benefit from the continuous correction provided by taping in order to limit the development of improper upper limb motor schemas and to favour that of proper ones.

  4. Biocompatible Adhesives

    DTIC Science & Technology

    1991-03-01

    pressure sensitive elastomer, polyisobutylene. with water soluble adhesives such as carboxy methyl ceiiulose, pectin and gelatin for adhesion to... cellulose and nylon films, were most often used in 180 peel adhesion tests on the adhesives. Films were cast on one substrate and the other was moistened...irritation. 4. Peel adhesion to hydrated cellulose , nylon and cotton cloth substrates was satisfactory. So too was the peel adhesion as a function of

  5. Evaluation of non-specular reflecting silvered Teflon and filled adhesives

    NASA Technical Reports Server (NTRS)

    Bourland, G.; Cox, R. L.

    1981-01-01

    A non-specular silver-Teflon tape thermal control coating was tested to provide the data necessary to qualify it for use on the Space Shuttle Orbiter radiators. Effects of cure cycle temperature and pressure on optical and mechanical properties on the silver-Teflon tape were evaluated. The baseline Permacel P-223 adhesive, used with the specular silver-Teflon tape initially qualified for the Orbiter radiators, and four alternate metal-filled and unfilled adhesives were evaluated. Tests showed the cure process has no effect on the silver-Teflon optical properties, and that the baseline adhesive cure cycle gives best results. In addition the P-223 adhesive bond is more reproducible than the alternates, and the non-specular tape meets both the mechanical and the optical requirements of the Orbiter radiator coating specification. Existing Orbiter coating techniques were demonstrated to be effective in aplying the non-specular tape to a curved panel simulating the radiators. Author

  6. Magnetization loss for stacks of ReBCO tapes

    NASA Astrophysics Data System (ADS)

    Bykovsky, N.; De Marzi, G.; Uglietti, D.; Bruzzone, P.; Muzzi, L.

    2017-02-01

    The AC loss measurements of the high temperature superconductor (HTS) cable prototype in the EDIPO test facility motivated detailed investigations of the loss contributions from the tape, strand and cable stages of the HTS fusion conductor design proposed at the Swiss Plasma Center. As an initial step of the task, magnetization tests of soldered stacks of HTS tapes were carried out at temperatures of 5 and 77 {{K}} and magnetic fields up to 12 {{T}} using the vibrating sample magnetometer technique. The influence on the magnetization loss of the number of tapes, width of the tape, field’s orientation and tape’s manufacturer is studied experimentally performing both the major and minor magnetization loops with different ramp rates of the applied magnetic field. In order to validate the test results, a numerical model is developed and presented in this work. From the numerical model we also deduced an analytical approach for the magnetization loss in the stacks of tapes with arbitrary number of tapes in the critical state model. Comparison between the measured and estimated magnetization loss of the cable prototypes is reported as well.

  7. Blister Test for Measurements of Adhesion and Adhesion Degradation of Organic Polymers on AA2024-T3

    NASA Astrophysics Data System (ADS)

    Rincon Troconis, Brendy Carolina

    A key parameter for the performance of corrosion protective coatings applied to metals is adhesion. Surface preparation prior to coating application is known to be critical, but there is a lack of understanding of what controls adhesion. Numerous techniques have been developed in the last decades to measure the adhesion strength of coatings to metals. Nonetheless, they are generally non-quantitative, non-reproducible, performed in dry conditions, or overestimate adhesion. In this study, a quantitative and reproducible technique, the Blister Test (BT), is used. The BT offers the ability to study the effects of a range of parameters, including the presence or absence of a wetting liquid, and simulates the stress situation in the coating/substrate interface. The effects of roughness and surface topography were studied by the BT and Optical Profilometry, using AA2024-T3 substrates coated with polyvinyl butyral (PVB). Random abrasion generated a surface with lower average roughness than aligned abrasion due to the continual cross abrasion of the grooves. The BT could discern the effects of different mechanical treatments. An adhesion strength indicator was defined and found to be a useful parameter. The effectiveness of standard adhesion techniques such as ASTM D4541 (Pull-off Test) and ASTM D3359 (Tape Test) was compared to the BT. Also, different attempts to measure adhesion and adhesion degradation of organic polymers to AA2024-T3 were tested. The pull-off test does not produce adhesive failure across the entire interface, while the tape test is a very qualitative technique and does not discern between the effects of different coating systems on the adhesion performance. The BT produces adhesive failure of the primer studied, is very reproducible, and is able to rank different coating systems. Therefore, it was found to be superior to the others. The approaches tested for adhesion degradation were not aggressive enough to have a measurable effect. The effects of

  8. TAPE: A Biodegradable Hemostatic Glue Inspired by a Ubiquitous Compound in Plants for Surgical Application.

    PubMed

    Kim, Keumyeon; Lee, Haeshin; Hong, Seonki

    2016-06-08

    This video describes the simplest protocol for preparing biodegradable surgical glue that has an effective hemostatic ability and greater water-resistant adhesion strength than commercial tissue adhesives. Medical adhesives have attracted great attention as potential alternative tools to sutures and staples due to their convenience in usage with minimal invasiveness. Although there are several protocols for developing tissue adhesives including those commercially available such as fibrin glues and cyanoacrylate-based materials, mostly they require a series of chemical syntheses of organic molecules, or complicated protein-purification methods, in the case of bio-driven materials (i.e., fibrin glue). Also, the development of surgical glues exhibiting high adhesive properties while maintaining biodegradability is still a challenge due to difficulties in achieving good performance in the wet environment of the body. We illustrate a new method to prepare a medical glue, known as TAPE, by the weight-based separation of a water-immiscible supramolecular aggregate formed after a physical mixing of a plant-derived, wet-resistant adhesive molecule, Tannic Acid (TA), and a well-known biopolymer, Poly(Ethylene) glycol (PEG). With our approach, TAPE shows high adhesion strength, which is 2.5-fold more than commercial fibrin glue in the presence of water. Furthermore, TAPE is biodegradable in physiological conditions and can be used as a potent hemostatic glue against tissue bleeding. We expect the widespread use of TAPE in a variety of medical settings and drug delivery applications, such as polymers for muco-adhesion, drug depots, and others.

  9. Grit Blasting Scribes Coats For Tests Of Adhesion

    NASA Technical Reports Server (NTRS)

    Novak, Howard L.

    1991-01-01

    Grit-blasting technique for cutting line gaps in paints, hard coats, lubricants, and other coating films undergoing development. Line gaps cut in chevron patterns, groups of parallel lines, or other prescribed patterns, in preparation for testing adhesions of coats to substrates by attempting to peel patterned areas off with adhesive tapes. Damage to substrate reduced.

  10. Nondestructive Biological Evidence Collection with Alternative Swabs and Adhesive Lifters.

    PubMed

    Plaza, Dane T; Mealy, Jamia L; Lane, J Nicholas; Parsons, M Neal; Bathrick, Abigail S; Slack, Donia P

    2016-03-01

    In forensic science, biological material is typically collected from evidence via wet/dry double swabbing with cotton swabs, which is effective but can visibly damage an item's surface. When an item's appearance must be maintained, dry swabbing and tape-lifting may be employed as collection techniques that are visually nondestructive to substrates' surfaces. This study examined the efficacy of alternative swab matrices and adhesive lifters when collecting blood and fingerprints from glass, painted drywall, 100% cotton, and copy paper. Data were evaluated by determining the percent profile and quality score for each STR profile generated. Hydraflock(®) swabs, BVDA Gellifters(®) , and Scenesafe FAST™ tape performed as well as or better than cotton swabs when collecting fingerprints from painted drywall and 100% cotton. Collection success was also dependent on the type of biological material sampled and the substrate on which it was deposited. These results demonstrated that alternative swabs and adhesive lifters can be effective for nondestructive DNA collection from various substrates.

  11. Novel digital optical tape recorder

    NASA Astrophysics Data System (ADS)

    Oakley, William S.

    1996-01-01

    A novel very high performance digital optical tape recorder is described. Linear tape motion at 4.2 meters per second and simultaneous writing of about 80 parallel bit tracks with a data density of three bits per micron per track enables a data rate of 1,000 Megabits per second, sufficient for a data rate of 100 megabytes per second with error correction. One micron track to track spacing gives a data capacity of one Terabyte (1,000 GB) in a single '3480' style tape cartridge shell. A single beam from a frequency doubled, laser diode pumped, solid state (2X- LDP-SS) laser is split into a multiplicity of like beams, each of which is then independently modulated at 12.5 MHz for recording.

  12. Buddy Taping: Is It a Safe Method for Treatment of Finger and Toe Injuries?

    PubMed Central

    Won, Sung Hun; Lee, Sanglim; Chung, Chin Youb; Sung, Ki Hyuk; Kim, Tae Gyun; Choi, Young; Lee, Sang Hyeong; Kwon, Dae Gyu; Ha, Jae Hong; Lee, Seung Yeol; Park, Moon Seok

    2014-01-01

    Background Buddy taping is a well known and useful method for treating sprains, dislocations, and other injuries of the fingers or toes. However, the authors have often seen complications associated with buddy taping such as necrosis of the skin, infections, loss of fixation, and limited joint motion. To our knowledge, there are no studies regarding the complications of buddy taping. The purpose of this study was to report the current consensus on treating finger and toe injuries and complications of buddy taping by using a specifically designed questionnaire. Methods A questionnaire was designed for this study, which was regarding whether the subjects were prescribed buddy taping to treat finger and toe injuries, reasons for not using it, in what step of injury treatment it was use, indications, complications, kinds of tape for fixation, and special methods for preventing skin injury. Fifty-five surgeons agreed to participate in the study and the survey was performed in a direct interview manner at the annual meetings of the Korean Pediatric Orthopedic Association and Korean Society for Surgery of the Hand, in 2012. Results Forty-eight surgeons (87%) used buddy taping to treat finger and toe injuries, especially proximal interphalangeal (PIP) injuries of the hand, finger fractures, toe fractures, metacarpophalangeal injuries of the hand, and PIP injuries of the foot. Sixty-five percent of the surgeons experienced low compliance. Forty-five percent of the surgeons observed skin injuries on the adhesive area of the tape, and skin injuries between the injured finger and healthy finger were observed by 45% of the surgeons. Conclusions This study sheds light on the current consensus and complications of buddy taping among physicians. Low compliance and skin injury should be considered when the clinician treats finger and toe injuries by using buddy taping. PMID:24605186

  13. High-temperature adhesives for polyimide films

    NASA Technical Reports Server (NTRS)

    St. Clair, A. K.; St. Clair, T. L.; Slemp, W. S.

    1979-01-01

    Linear condensation polyimides which are high-temperature polymers show promise as adhesives which form flexible film coatings compatible with polyimide films. Materials are advantageous since they can be supplied as flexible tape, already B-staged and ready for bonding.

  14. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, E.B.; Muller, A.C.

    1983-07-15

    The present invention is a cable which, although constructed from inexpensive polyolefin tapes and using typical impregnating oils, furnishes high voltage capability up to 765 kV, and has such excellent dielectric characteristics and heat transfer properties that it is capable of operation at capacities equal to or higher than presently available cables at a given voltage. This is accomplished by using polyethylene, polybutene or polypropylene insulating tape which has been specially processed to attain properties which are not generally found in these materials, but are required for their use in impregnated electrical cables. Chief among these properties is compatibility with impregnating oil.

  15. Superconducting flat tape cable magnet

    DOEpatents

    Takayasu, Makoto

    2015-08-11

    A method for winding a coil magnet with the stacked tape cables, and a coil so wound. The winding process is controlled and various shape coils can be wound by twisting about the longitudinal axis of the cable and bending following the easy bend direction during winding, so that sharp local bending can be obtained by adjusting the twist pitch. Stack-tape cable is twisted while being wound, instead of being twisted in a straight configuration and then wound. In certain embodiments, the straight length should be half of the cable twist-pitch or a multiple of it.

  16. Personal miniature electrophysiological tape recorder

    NASA Technical Reports Server (NTRS)

    Green, H.

    1981-01-01

    The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.

  17. Personal miniature electrophysiological tape recorder

    NASA Astrophysics Data System (ADS)

    Green, H.

    1981-11-01

    The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.

  18. RESIDUAL RISK ASSESSMENT: MAGNETIC TAPE ...

    EPA Pesticide Factsheets

    This document describes the residual risk assessment for the Magnetic Tape Manufacturing source category. For stationary sources, section 112 (f) of the Clean Air Act requires EPA to assess risks to human health and the environment following implementation of technology-based control standards. If these technology-based control standards do not provide an ample margin of safety, then EPA is required to promulgate addtional standards. This document describes the methodology and results of the residual risk assessment performed for the Magnetic Tape Manufacturing source category. The results of this analyiss will assist EPA in determining whether a residual risk rule for this source category is appropriate.

  19. The statistical evaluation of duct tape end match as physical evidence

    NASA Astrophysics Data System (ADS)

    Chan, Ka Lok

    Duct tapes are often submitted to crime laboratories as evidence associated with abductions, homicides, or construction of explosive devices. As a result, trace evidence examiners are often asked to analyze and compare commercial duct tapes so that they can establish possible evidentiary links. Duct tape end matches are believed to be the strongest association between exemplar and question samples because they are considered as evidence with unique individual characteristics. While end match analysis and comparison have long been undertaken by trace evidence examiners, there is a significant lack of scientific research for associating two or more segments of duct tapes. This study is designed to obtain statistical inferences on the uniqueness of duct tape tears. Three experiments were devised to compile the basis for a statistical assessment of the probability of duct tape end matches along with a proposed error rate. In one experiment, we conducted the equivalent of 10,000 end match examinations with an error rate of 0%. In the second experiment, we performed 2,704 end match examinations having 0% error rate. In the third experiment, using duct tape by an Elmendorf Tear tester, we conducted 576 end match examinations with an error rate of 0% and having all samples correctly associated. The results of this study indicate that end matches are distinguishable among a single roll of duct tape and between two different rolls of duct tape having very similar surface features and weave pattern.

  20. Adhesion and Thin-Film Module Reliability: Preprint

    SciTech Connect

    McMahon, T. J.; Jorgensen, G. J.

    2006-05-01

    Among the infrequently measured but essential properties for thin-film (T-F) module reliability are the interlayer adhesion and cohesion within a layer. These can be cell contact layers to glass, contact layers to the semiconductor, encapsulant to cell, glass, or backsheet, etc. We use an Instron mechanical testing unit to measure peel strengths at 90{sup o} or 180{sup o} and, in some cases, a scratch and tape pull test to evaluate inter-cell layer adhesion strengths. We present peel strength data for test specimens laminated from the three T-F technologies, before and after damp heat, and in one instance at elevated temperatures. On laminated T-F cell samples, failure can occur uniformly at any one of the many interfaces, or non-uniformly across the peel area at more than one interface. Some peel strengths are << 1 N/mm. This is far below the normal Instron mechanical testing unit Instron mechanical testing unit; glass interface values of >10 N/mm. We measure a wide range of adhesion strengths and suggest that adhesion measured under higher temperature and relative humidity conditions is more relevant for module reliability.

  1. Materials for Heated Head Automated Thermoplastic Tape Placement

    NASA Technical Reports Server (NTRS)

    Jensen, Brian J.; Kinney, Megan C.; Cano, Roberto J.; Grimsley, Brian W.

    2012-01-01

    NASA Langley Research Center (LaRC) is currently pursuing multiple paths to develop out of autoclave (OOA) polymeric composite materials and processes. Polymeric composite materials development includes the synthesis of new and/or modified thermosetting and thermoplastic matrix resins designed for specific OOA processes. OOA processes currently under investigation include vacuum bag only (VBO) prepreg/composite fabrication, resin transfer molding (RTM), vacuum assisted resin transfer molding (VARTM) and heated head automated thermoplastic tape placement (HHATP). This paper will discuss the NASA Langley HHATP facility and capabilities and recent work on characterizing thermoplastic tape quality and requirements for quality part production. Samples of three distinct versions of APC-2 (AS4/PEEK) thermoplastic dry tape were obtained from two materials vendors, TENCATE, Inc. and CYTEC Engineered Materials** (standard grade and an experimental batch). Random specimens were taken from each of these samples and subjected to photo-microscopy and surface profilometry. The CYTEC standard grade of APC-2 tape had the most voids and splits and the highest surface roughness and/or waviness. Since the APC-2 tape is composed of a thermoplastic matrix, it offers the flexibility of reprocessing to improve quality, and thereby improve final quality of HHATP laminates. Discussions will also include potential research areas and future work that is required to advance the state of the art in the HHATP process for composite fabrication.

  2. A Study of Audio Tape: Part II

    ERIC Educational Resources Information Center

    Reen, Noel K.

    1975-01-01

    To evaluate reel audio tape, tests were performed to identify: signal-to-noise ratio, total harmonic distortion, dynamic response, frequency response, biased and virgin tape noise, dropout susceptibility and oxide coating uniformity. (SCC)

  3. Field spectrometer (S191H) preprocessor tape quality test program design document

    NASA Technical Reports Server (NTRS)

    Campbell, H. M.

    1976-01-01

    Program QA191H performs quality assurance tests on field spectrometer data recorded on 9-track magnetic tape. The quality testing involves the comparison of key housekeeping and data parameters with historic and predetermined tolerance limits. Samples of key parameters are processed during the calibration period and wavelength cal period, and the results are printed out and recorded on an historical file tape.

  4. A Study of Audio Tape

    ERIC Educational Resources Information Center

    Reen, Noel K.

    1975-01-01

    This is part I of a report on a study comparing reel and cassette tapes for signal-to-noise ration, total harmonic distortion, dynamic response, frequency response, bias and virgin noise and oxide coating uniformity. Test equipment and procedures are described and results are discussed. Charts detail research findings. (CHK)

  5. Marine Bioinspired Underwater Contact Adhesion.

    PubMed

    Clancy, Sean K; Sodano, Antonio; Cunningham, Dylan J; Huang, Sharon S; Zalicki, Piotr J; Shin, Seunghan; Ahn, B Kollbe

    2016-05-09

    Marine mussels and barnacles are sessile biofouling organisms that adhere to a number of surfaces in wet environments and maintain remarkably strong bonds. Previous synthetic approaches to mimic biological wet adhesive properties have focused mainly on the catechol moiety, present in mussel foot proteins (mfps), and especially rich in the interfacial mfps, for example, mfp-3 and -5, found at the interface between the mussel plaque and substrate. Barnacles, however, do not use Dopa for their wet adhesion, but are instead rich in noncatecholic aromatic residues. Due to this anomaly, we were intrigued to study the initial contact adhesion properties of copolymerized acrylate films containing the key functionalities of barnacle cement proteins and interfacial mfps, for example, aromatic (catecholic or noncatecholic), cationic, anionic, and nonpolar residues. The initial wet contact adhesion of the copolymers was measured using a probe tack testing apparatus with a flat-punch contact geometry. The wet contact adhesion of an optimized, bioinspired copolymer film was ∼15.0 N/cm(2) in deionized water and ∼9.0 N/cm(2) in artificial seawater, up to 150 times greater than commercial pressure-sensitive adhesive (PSA) tapes (∼0.1 N/cm(2)). Furthermore, maximum wet contact adhesion was obtained at ∼pH 7, suggesting viability for biomedical applications.

  6. New optimized DNA extraction protocol for fingerprints deposited on a special self-adhesive security seal and other latent samples used for human identification.

    PubMed

    Kopka, Julieta; Leder, Monika; Jaureguiberry, Stella M; Brem, Gottfried; Boselli, Gabriel O

    2011-09-01

    Obtaining complete short tandem repeat (STR) profiles from fingerprints containing minimal amounts of DNA, using standard extraction techniques, can be difficult. The aim of this study was to evaluate a new kit, Fingerprint DNA Finder (FDF Kit), recently launched for the extraction of DNA and STR profiling from fingerprints placed on a special device known as Self-Adhesive Security Seal Sticker(®) and other latent fingerprints on forensic evidentiary material like metallic guns. The DNA extraction system is based on a reversal of the silica principle, and all the potential inhibiting substances are retained on the surface of a special adsorbent, while nucleic acids are not bound and remain in solution dramatically improving DNA recovery. DNA yield was quite variable among the samples tested, rendering in most of the cases (>90%) complete STR profiles, free of PCR inhibitors, and devoid of artifacts. Even samples with DNA amount below 100 pg could be successfully analyzed.

  7. High density tape/head interface study

    NASA Technical Reports Server (NTRS)

    Csengery, L. C.

    1983-01-01

    The high energy (H sub c approximately or = to 650 oersteds) tapes and high track density (84 tracks per inch) heads investigated had, as its goal, the definition of optimum combinations of head and tape, including the control required of their interfacial dynamics that would enable the manufacture of high rate (150 Mbps) digital tape recorders for unattended space flight.

  8. Analysis of cache for streaming tape drive

    NASA Technical Reports Server (NTRS)

    Chinnaswamy, V.

    1993-01-01

    A tape subsystem consists of a controller and a tape drive. Tapes are used for backup, data interchange, and software distribution. The backup operation is addressed. During a backup operation, data is read from disk, processed in CPU, and then sent to tape. The processing speeds of a disk subsystem, CPU, and a tape subsystem are likely to be different. A powerful CPU can read data from a fast disk, process it, and supply the data to the tape subsystem at a faster rate than the tape subsystem can handle. On the other hand, a slow disk drive and a slow CPU may not be able to supply data fast enough to keep a tape drive busy all the time. The backup process may supply data to tape drive in bursts. Each burst may be followed by an idle period. Depending on the nature of the file distribution in the disk, the input stream to the tape subsystem may vary significantly during backup. To compensate for these differences and optimize the utilization of a tape subsystem, a cache or buffer is introduced in the tape controller. Most of the tape drives today are streaming tape drives. A streaming tape drive goes into reposition when there is no data from the controller. Once the drive goes into reposition, the controller can receive data, but it cannot supply data to the tape drive until the drive completes its reposition. A controller can also receive data from the host and send data to the tape drive at the same time. The relationship of cache size, host transfer rate, drive transfer rate, reposition, and ramp up times for optimal performance of the tape subsystem are investigated. Formulas developed will also show the advantages of cache watermarks to increase the streaming time of the tape drive, maximum loss due to insufficient cache, tradeoffs between cache and reposition times and the effectiveness of cache on a streaming tape drive due to idle times or interruptions due in host transfers. Several mathematical formulas are developed to predict the performance of the tape

  9. Electric currents in REBaCuO superconducting tapes

    NASA Astrophysics Data System (ADS)

    Jirsa, M.; Rameš, M.; Ďuran, I.; Melíšek, T.; Kováč, P.; Viererbl, L.

    2017-04-01

    Magnetic induction and current transport techniques were employed to test the electromagnetic performance of 22 samples of superconducting REBaCuO tapes of several manufacturers with the aim to select the best candidates for wiring new generation superconducting magnets for fusion reactors. An extraordinary shape of pinning force density as a function of magnetic field was observed in ‘advanced pinning, AP’ SuperPower tapes. The induced currents enabled us to classify the tapes and show the best ones, at low temperatures and high magnetic fields on the one hand and at high temperatures and low magnetic fields on the other hand. Transport current experiments confirmed the results. Moreover, they provided information on current anisotropy, which appeared to be specific for each tape type. The present results formed a basis for the ongoing study of neutron irradiation impact on the tapes’ properties. The first experiment showed that neutron irradiation by the fluence of 2.1 E22 m‑2 either enhances, reduces, or has no effect on the tape’s properties, according to the tape pinning structure.

  10. Intrauterine Adhesions

    MedlinePlus

    ... adhesion formation are infections of the uterine lining (endometritis), removal of fibroids in the cavity of the ... to prevent adhesions from reforming. Hormonal treatment with estrogen and NSAIDs are frequently prescribed after surgery to ...

  11. AC loss measurements of twisted and untwisted BSCCO multifilamentary tapes

    NASA Astrophysics Data System (ADS)

    Jiang, Zhenan; Amemiya, Naoyuki; Nishioka, Takamasa; Oh, Sang-Soo

    2005-01-01

    AC losses in twisted and untwisted BSCCO multifilamentary superconducting tapes with Ag matrix developed in DAPAS program were measured by an electrical method. Magnetization and transport losses were measured by a pick-up coil and by a voltage taps. Total AC loss during simultaneous application of AC transport current and an AC transverse magnetic field was given by the sum of the magnetization and transport losses measured during this simultaneous application. The magnetization loss without transport current of untwisted and twisted tapes was measured first to evaluate the effect of twisting to decouple filaments. Then, the total AC loss of the twisted tape was measured in transverse magnetic fields with various amplitudes and orientations, while the amplitude of the transport current was fixed. The measured total AC loss in a parallel transverse magnetic field was compared with some theoretical models to study the detailed characteristics of the measured total AC loss of the sample.

  12. Digital tape unit test facility software

    NASA Technical Reports Server (NTRS)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  13. An experimental study of double-peeling mechanism inspired by biological adhesive systems

    NASA Astrophysics Data System (ADS)

    Heepe, Lars; Raguseo, Saverio; Gorb, Stanislav N.

    2017-02-01

    Double- (or multiple-) peeling systems consist of two (or numerous) tapes adhering to a substrate and having a common hinge, where the pulling force is applied. Biological systems, consisting of tape-like (or spatula-like) contact elements, are widely observed in adhesive pads of flies, beetles, spiders, and geckos. It was previously hypothesized and analytically modeled that the simultaneous use of two or more such tape-like contacts in the opposite movement of contralateral legs during ceiling locomotion leads to enhanced, robust, and stable overall attachment, if compared to independently working contact points. In this paper, this biological solution for smart adhesion is demonstrated in an experiment using elastic adhesive tapes. The obtained results not only aided in explaining the functional mechanism of biological adhesive systems, but also in providing an experimental proof for biological observations and previous theoretical models.

  14. High density tape casting system

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr. (Inventor)

    1989-01-01

    A system is provided for casting thin sheets (or tapes) of particles bound together, that are used for oxygen membranes and other applications, which enables the particles to be cast at a high packing density in a tape of uniform thickness. A slurry contains the particles, a binder, and a solvent, and is cast against the inside walls of a rotating chamber. Prior to spraying the slurry against the chamber walls, a solvent is applied to a container. The solvent evaporates to saturate the chamber with solvent vapor. Only then is the slurry cast. As a result, the slurry remains fluid long enough to spread evenly over the casting surface formed by the chamber, and for the slurry particles to become densely packed. Only then is the chamber vented to remove solvent, so the slurry can dry. The major novel feature is applying solvent vapor to a rotating chamber before casting slurry against the chamber walls.

  15. Multilingual health education tapes project.

    PubMed

    Vryheid, R

    1992-01-01

    The success of Thailand's 1985 malaria education cassette tapes project motivated the Highland Development Program to produce tapes in 6 tribal languages on family planning, maternal and child health, nutrition, and disease prevention. Staff produced tapes using a drama or radio magazine format as a series of short features with music and sound effects. Scriptwriters consulted villagers, broadcasting professionals, research workers, and health officials to tailor messages to the various hill tribes. They tried to avoid conflict between traditional and modern concepts and to minimize distrust of government services. The scriptwriters used basically short, grammatically simple sentences, and colloquial Thai to simplify translation. The staff tried to recruit literate, adult, native speakers of the target languages with some experience in health education in their own languages. Obstacles encountered with translation included some languages used an uncommon alphabet or translators did not know their own alphabet. The program backtranslated the scripts to assure the accuracy of the messages and the appropriateness of the words used. Backtranslation revealed deficiencies in the translated messages. Altering the meaning of technical terms tended to be simple mistakes, words with multiple meanings, and exaggeration of problems and/or solutions. Translators also sometimes failed to adapt cultural ideas to those of their tribes. For example, some persons translated all possible misconceptions about a disease yet the tribes did not have all the misconceptions. As of early 1992, recording, pretesting, distribution, and follow up had not yet taken place. The staff should meet with a recording studio to coordinate production including technicians and translators identifying means to communicate. Staff should be aware of signs of poor translation which they may have missed earlier and surfaces during recording. Pretesting should occur among literate and illiterate members of

  16. Digital terrain tapes: user guide

    USGS Publications Warehouse

    ,

    1980-01-01

    DMATC's digital terrain tapes are a by-product of the agency's efforts to streamline the production of raised-relief maps. In the early 1960's DMATC developed the Digital Graphics Recorder (DGR) system that introduced new digitizing techniques and processing methods into the field of three-dimensional mapping. The DGR system consisted of an automatic digitizing table and a computer system that recorded a grid of terrain elevations from traces of the contour lines on standard topographic maps. A sequence of computer accuracy checks was performed and then the elevations of grid points not intersected by contour lines were interpolated. The DGR system produced computer magnetic tapes which controlled the carving of plaster forms used to mold raised-relief maps. It was realized almost immediately that this relatively simple tool for carving plaster molds had enormous potential for storing, manipulating, and selectively displaying (either graphically or numerically) a vast number of terrain elevations. As the demand for the digital terrain tapes increased, DMATC began developing increasingly advanced digitizing systems and now operates the Digital Topographic Data Collection System (DTDCS). With DTDCS, two types of data elevations as contour lines and points, and stream and ridge lines are sorted, matched, and resorted to obtain a grid of elevation values for every 0.01 inch on each map (approximately 200 feet on the ground). Undefined points on the grid are found by either linear or or planar interpolation.

  17. Hygroscopic properties of magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Cuddihy, E. F.

    1976-01-01

    Relative humidity has been recognized as an important environmental factor in many head-tape interface phenomena such as headwear, friction, staining, and tape shed. Accordingly, the relative humidity is usually specified in many applications of tape use, especially when tape recorders are enclosed in hermetically sealed cases. Normally, the relative humidity is believed regulated by humidification of the fill gas to the specification relative humidity. This study demonstrates that the internal relative humidity in a sealed case is completely controlled by the time-dpendence of the hygroscopic properties of the pack of magnetic recording tape. Differences are found in the hygroscopic properties of the same brand of tape, which apparently result from aging, and which may have an effect on the long-term humidity-regulating behavior in a sealed case, and on the occurrence of head-tape interface phenomena from the long-term use of the tape. Results are presented on the basic hygroscopic properties of magnetic tape, its humidity-regulating behavior in a sealed case, and a theoretical commentary on the relative humidity dependence of head-wear by tape, is included.

  18. Non-contact inline monitoring of thermoplastic CFRP tape quality using air-coupled ultrasound

    NASA Astrophysics Data System (ADS)

    Essig, W.; Fey, P.; Meiler, S.; Kreutzbruck, M.

    2017-02-01

    Beginning with the aerospace industry, fiber reinforced plastics have spread towards many applications such as automotive, civil engineering as well as sports and leisure articles. Their superior strength and stiffness to mass ratio made them the number one material for achieving high performance. Especially continuous fiber reinforced plastics allow for the construction of structures which are custom tailored to their mechanical loads by adjusting the paths of the fibers to the loading direction. The two main constituents of CFRP are carbon fibers and matrix. Two possibilities for matrix material exist: thermosetting and thermoplastic matrix. While thermosetting matrix may yield better properties with respect to thermal loads, thermoplasticity opens a wide range of applications due to weldability, shapeability, and compatibility to e.g. injection molded thermoplastic materials. Thin (0.1 mm) thermoplastic continuous fiber CFRP tapes with a width of 100 mm were examined using air-coupled ultrasound. Transducers were arranged in reflection as well as transmission setup. By slanted incidence of the ultrasound on the tape surface, guided waves were excited in the material in fiber direction and perpendicular to the fiber direction. Artificial defects - fiber cuts, matrix cuts, circular holes, low velocity impacts from tool drop, and sharp bends - were produced. Experiments on a stationary tape showed good detectability of all artificial defects by guided waves. Also the effects of variation in material properties, fiber volume content and fiber matrix adhesion being the most relevant, on guided wave propagation were examined, to allow for quality assessment. Guided wave measurements were supported by destructive analysis. Also an apparatus containing one endless loop of CFRP tape was constructed and built to simulate inline testing of CFRP tapes, as it would be employed in a CFRP tape production environment or at a CFRP tape processing facility. The influences of tape

  19. Numerical and Experimental Investigation of the Electromechanical Behavior of REBCO Tapes

    NASA Astrophysics Data System (ADS)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2015-12-01

    To fully characterize the electromechanical behavior of a Twisted Stacked-Tape Cable (TSTC) it is important to understand the performance of the individual REBCO tapes under various loading conditions. Numerical modeling and experimentation have been used to investigate the electromechanical characteristics of two commercially available REBCO tapes (SuperPower and SuNAM). Tension and combined tension-torsion experiments on single tapes have been continued, from prior preliminary studies, to characterize their critical current behavior and mechanical strength. Additionally, structural finite element analysis was performed on single tapes under tension and combined tension-torsion to investigate the strain dependence of the critical current. The numerical results were compared to the experimental findings for validation. The SuNAM experimental data matched the numerical model very well while the SuperPower tape experienced degradation at lower stress and strain than predicted in the model. The Superpower tape also displayed greater variability in critical current between different samples as compared with the SuNAM tape.

  20. 75 FR 59695 - Foreign-Trade Zone 169-Manatee County, Florida; Extension of Subzone; Aso LLC (Adhesive Bandage...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-28

    ... (Adhesive Bandage Manufacturing); Sarasota County, FL An application has been submitted to the Foreign-Trade... strips per year) was approved by the Board in 2000 for the manufacture of adhesive bandages under FTZ... has at times instead used various duty suspension provisions on adhesive tape. Aso is now...

  1. Carbon nanotube dry adhesives with temperature-enhanced adhesion over a large temperature range

    NASA Astrophysics Data System (ADS)

    Xu, Ming; Du, Feng; Ganguli, Sabyasachi; Roy, Ajit; Dai, Liming

    2016-11-01

    Conventional adhesives show a decrease in the adhesion force with increasing temperature due to thermally induced viscoelastic thinning and/or structural decomposition. Here, we report the counter-intuitive behaviour of carbon nanotube (CNT) dry adhesives that show a temperature-enhanced adhesion strength by over six-fold up to 143 N cm-2 (4 mm × 4 mm), among the strongest pure CNT dry adhesives, over a temperature range from -196 to 1,000 °C. This unusual adhesion behaviour leads to temperature-enhanced electrical and thermal transports, enabling the CNT dry adhesive for efficient electrical and thermal management when being used as a conductive double-sided sticky tape. With its intrinsic thermal stability, our CNT adhesive sustains many temperature transition cycles over a wide operation temperature range. We discover that a `nano-interlock' adhesion mechanism is responsible for the adhesion behaviour, which could be applied to the development of various dry CNT adhesives with novel features.

  2. Carbon nanotube dry adhesives with temperature-enhanced adhesion over a large temperature range

    PubMed Central

    Xu, Ming; Du, Feng; Ganguli, Sabyasachi; Roy, Ajit; Dai, Liming

    2016-01-01

    Conventional adhesives show a decrease in the adhesion force with increasing temperature due to thermally induced viscoelastic thinning and/or structural decomposition. Here, we report the counter-intuitive behaviour of carbon nanotube (CNT) dry adhesives that show a temperature-enhanced adhesion strength by over six-fold up to 143 N cm−2 (4 mm × 4 mm), among the strongest pure CNT dry adhesives, over a temperature range from −196 to 1,000 °C. This unusual adhesion behaviour leads to temperature-enhanced electrical and thermal transports, enabling the CNT dry adhesive for efficient electrical and thermal management when being used as a conductive double-sided sticky tape. With its intrinsic thermal stability, our CNT adhesive sustains many temperature transition cycles over a wide operation temperature range. We discover that a ‘nano-interlock' adhesion mechanism is responsible for the adhesion behaviour, which could be applied to the development of various dry CNT adhesives with novel features. PMID:27849052

  3. Tape-recorded Lectures With Slide Synchronization

    ERIC Educational Resources Information Center

    Goodhue, D.

    1969-01-01

    Describes "Taped Explanation Slide Synchronization" programs used for individual study or group showing in college zoology. Discusses preparation of programs, class organization, equipment, and costs. (EB)

  4. Continuous critical current measurement of high-temperature superconductor tapes with magnetic substrates using magnetic-circuit method.

    PubMed

    Zou, S N; Gu, C; Qu, T M; Han, Z

    2013-10-01

    The critical current (I(c)) of high-temperature superconductor (HTS) tapes has to be examined not only for short samples, but also for the entire tape, because local weak points can possibly lead to the quenching of the whole HTS device. Some methods were reported for continuous I(c) measurement along the length of a HTS tape, but few of them were applicable to tapes with magnetic substrates represented by YBa2Cu3O(7-δ)(YBCO)-coated conductors based on Ni5W alloy substrate by rolling assisted bi-axially textured substrate process. We previously presented a contact-free method using magnetic circuits to measure I(c) continuously of long HTS tapes, namely the magnetic-circuit (MC) method. This method has been previously applied with high speed and resolution to measure I(c) of HTS tapes with non-magnetic substrates, due to its resistance to noise aroused by mechanical vibration. In this work, its ability to measure HTS tapes with magnetic substrates is demonstrated both theoretically and experimentally. A 100 m long commercial YBCO tape based on Ni5W alloy substrate was measured and regular I(c) fluctuations were discovered. The MC method can be a powerful tool for quality control of HTS tapes, especially for tapes with magnetic substrates.

  5. Flexible backbone aromatic polyimide adhesives

    NASA Technical Reports Server (NTRS)

    Progar, Donald J.; St. Clair, Terry L.

    1989-01-01

    Continuing research at Langley Research Center on the synthesis and development of new inexpensive flexible aromatic polyimides as adhesives has resulted in a material identified as LARC-F-SO2 with similarities to polyimidesulfone, PISO2, and other flexible backbone polyimides recently reported by Progar and St. Clair. Also prepared and evaluated was an endcapped version of PISO2. These two polymers were compared with LARC-TPI and LARC-STPI, polyimides research in our laboratory and reported in the literature. The adhesive evaluation, primarily based on lap shear strength (LSS) tests at RT, 177 C and 204 C, involved preparing adhesive tapes, conducting bonding studies and exposing lap shear specimens to 204 C air for up to 1000 hrs and to a 72-hour water boil. The type of adhesive failure as well as the Tg was determined for the fractured specimens. The results indicate that LARC-TPI provides the highest LSSs. LARC-F-SO2, LARC-TPI and LARC-STPI all retain their strengths after thermal exposure for 1000 hrs and PISO2 retains greater than 80 percent of its control strengths. After a 72-hr water boil exposure, most of the four adhesive systems showed reduced strengths for all test temperatures although still retaining a high percentage of their original strength (greater than 60 percent) except for one case. The predominant failure type was cohesive with no significant change in the Tgs.

  6. Flexible backbone aromatic polyimide adhesives

    NASA Technical Reports Server (NTRS)

    Progar, Donald J.; St.clair, Terry L.

    1988-01-01

    Continuing research at Langley Research Center on the synthesis and development of new inexpensive flexible aromatic polyimides as adhesives has resulted in a material identified as LARC-F-SO2 with similarities to polyimidesulfone, PISO2, and other flexible backbone polyimides recently reported by Progar and St. Clair. Also prepared and evaluated was an endcapped version of PISO2. These two polymers were compared with LARC-TPI and LARC-STPI, polyimides research in our laboratory and reported in the literature. The adhesive evaluation, primarily based on lap shear strength (LSS) tests at RT, 177 C and 204 C, involved preparing adhesive tapes, conducting bonding studies and exposing lap shear specimens to 204 C air for up to 1000 hrs and to a 72-hour water boil. The type of adhesive failure as well as the Tg was determined for the fractured specimens. The results indicate that LARC-TPI provides the highest LSSs. LARC-F-SO2, LARC-TPI and LARC-STPI all retain their strengths after thermal exposure for 1000 hrs and PISO2 retains greater than 80 percent of its control strengths. After a 72-hr water boil exposure, most of the four adhesive systems showed reduced strengths for all test temperatures although still retaining a high percentage of their original strength (greater than 60 percent) except for one case. The predominant failure type was cohesive with no significant change in the Tgs.

  7. Roles of Poly(propylene Glycol) During Solvent-Based Lamination of Ceramic Green Tapes

    NASA Technical Reports Server (NTRS)

    Suppakarn, Nitinat; Ishida, Hatsuo; Cawley, James D.; Levine, Stanley R. (Technical Monitor)

    2000-01-01

    Solvent lamination for alumina green tapes is readily accomplished using a mixture of ethanol, toluene and poly(propylene glycol). After lamination, the PPG is clearly present as a discrete film at the interface between the laminated tapes. This condition, however, does not generate delamination during firing. Systematic sets of experiments are undertaken to determine the role of PPG in the lamination process and, specifically, the mechanism by which it is redistributed during subsequent processing. PPG slowly diffuses through the organic binder film at room temperature. The PPG diffusion rapidly increases as temperature is increased to 80 C. The key to the efficiency of adhesives during green-tape lamination is mutual solubility of the nonvolatile component of the glue and the base polymeric binder.

  8. Patterned Taping: A High-Efficiency Soft Lithographic Method for Universal Thin Film Patterning.

    PubMed

    Oh, Sangyoon; Park, Sang Kyu; Kim, Jin Hong; Cho, Illhun; Kim, Hyeong-Ju; Park, Soo Young

    2016-03-22

    As a universal lithographic technique for microscale/nanoscale film patterns, we develop a strategy for the use of soft lithographically patterned pressure-sensitive tape (patterned tape) as a pattern-transporting stamp material. Patterning was successfully implemented through the selective detachment and/or attachment of various thin films, including organic and metallic layers demanding no subsequent physical, thermal, or chemical treatment, as this incurs the risk of the deformation of the thin film and the deterioration of its functionalities. Its features of universal adhesion and flexibility enable pressure-sensitive tapes to form patterns on a variety of surfaces: organic, polymeric, and inorganic surfaces as well as flat, curved, uneven, and flexible substrates. Moreover, the proposed technique boasts the unique and distinct advantages of short operation time, supreme patterning yield, and multilayer stacking capability, which suggest considerable potential for their application to advanced optoelectronic device fabrication.

  9. Contact solid-phase microextraction with uncoated glass and polydimethylsiloxane-coated fibers versus solvent sampling for the determination of hydrocarbons in adhesion secretions of Madagascar hissing cockroaches Gromphadorrhina portentosa (Blattodea) by gas chromatography-mass spectrometry.

    PubMed

    Gerhardt, Heike; Schmitt, Christian; Betz, Oliver; Albert, Klaus; Lämmerhofer, Michael

    2015-04-03

    Molecular profiles of adhesion secretions of Gromphadorrhina portentosa (Madagascar hissing cockroach, Blattodea) were investigated by gas chromatography mass spectrometry with particular focus on a comprehensive analysis of linear and branched hydrocarbons. For this purpose, secretions from the tarsi (feet), possibly contributing to adhesion on smooth surfaces, and control samples taken from the tibiae (lower legs), which contain general cuticular hydrocarbons that are supposed to be not involved in the biological adhesion function, were analyzed and their molecular fingerprints compared. A major analytical difficulty in such a study constitutes the representative, spatially controlled, precise and reproducible sampling from a living insect as well as the minute quantities of insect secretions on both tarsi and tibiae. Thus, three different in vivo sampling methods were compared in terms of sampling reproducibility and extraction efficiency by replicate measurement of samples from tarsi and tibiae. While contact solid-phase microextraction (SPME) with a polydimethylsiloxane (PDMS) fiber showed higher peak intensities, a self-made uncoated glass fiber had the best repeatability in contact-SPME sampling. Chromatographic profiles of these two contact-SPME sampling methods were statistically not significantly different. Inter-individual variances were larger than potentially existing minor differences in molecular patterns of distinct sampling methods. Sampling by solvent extraction was time consuming, showed lower sensitivities and was less reproducible. In general, sampling by contact-SPME with a cheap glass fiber turned out to be a viable alternative to PDMS-SPME sampling. Hydrocarbon patterns of the tarsal adhesion secretions were qualitatively similar to those of epicuticular hydrocarbon profiles of the tibiae. However, hydrocarbons were in general less abundant in tarsal secretions than secretions from tibiae.

  10. Abdominal Adhesions

    MedlinePlus

    ... Adhesions 1 Ward BC, Panitch A. Abdominal adhesions: current and novel therapies. Journal of Surgical Research. 2011;165(1):91–111. Seek Help for ... and how to participate, visit the NIH Clinical Research Trials and You website ... Foundation for Functional Gastrointestinal Disorders 700 West Virginia ...

  11. Seal for permitting transfer of tape from one pressure region to a region of substantially different pressure

    DOEpatents

    Carter, H. Kennon; Mlekodaj, Ronald L.

    1977-01-01

    A seal is provided for allowing a thin flexible tape to be pulled from a high vacuum region (less than 10.sup.-.sup.6 torr) into atmospheric pressure. The tape first passes through a slit in an elastomer and thence through a pool of vacuum pump fluid into a differentially pumped volume. A second slit in an elastomer is the final seal element prior to exit of the tape to atmospheric pressure. The vacuum seal is utilized in a system for the rapid removal of samples, implanted in the surface of the tape, from a vacuum system to atmospheric pressure.

  12. Penetration studies of topically applied substances: Optical determination of the amount of stratum corneum removed by tape stripping.

    PubMed

    Lademann, J; Ilgevicius, A; Zurbau, O; Liess, H D; Schanzer, S; Weigmann, H J; Antoniou, C; Pelchrzim, R V; Sterry, W

    2006-01-01

    Tape stripping is a standard measuring method for the investigation of the dermatopharmacokinetics of topically applied substances using adhesive films. These tape strips are successively applied and removed from the skin after application and penetration of topically applied substances. Thus, layers of corneocytes and some amount of topical applied substances are removed. The amount of substances and the amount of stratum corneum removed with a single tape strip has to be determined for the calculation of the penetration profile. The topically applied substances removed from the skin can be determined by classical analytical methods like high-pressure liquid chromatography, mass spectroscopy, and spectroscopic measurements. The amount of corneocytes on the tape strips can be easily detected by their pseudoabsorption. In the present paper, an easy and cheap corneocyte density analyzer is presented that is based on a slide projector. Comparing the results of the measurements obtained by the corneocyte density analyzer and by uv-visible spectrometry, identical results were obtained.

  13. Three-dimensional microfluidic devices fabricated in layered paper and tape

    PubMed Central

    Martinez, Andres W.; Phillips, Scott T.; Whitesides, George M.

    2008-01-01

    This article describes a method for fabricating 3D microfluidic devices by stacking layers of patterned paper and double-sided adhesive tape. Paper-based 3D microfluidic devices have capabilities in microfluidics that are difficult to achieve using conventional open-channel microsystems made from glass or polymers. In particular, 3D paper-based devices wick fluids and distribute microliter volumes of samples from single inlet points into arrays of detection zones (with numbers up to thousands). This capability makes it possible to carry out a range of new analytical protocols simply and inexpensively (all on a piece of paper) without external pumps. We demonstrate a prototype 3D device that tests 4 different samples for up to 4 different analytes and displays the results of the assays in a side-by-side configuration for easy comparison. Three-dimensional paper-based microfluidic devices are especially appropriate for use in distributed healthcare in the developing world and in environmental monitoring and water analysis. PMID:19064929

  14. Use of a skin adhesive (octyl-2-cyanoacrylate) and the optimum reinforcing combination for suturing wounds.

    PubMed

    Chigira, Miho; Akimoto, Masataka

    2005-01-01

    The adhesion strength of a skin adhesive, octyl-2-cyanoacrylate (Dermabond), was measured under various conditions using porcine skin. The combined use of a skin adhesive and a skin closure tape (n = 5) was significantly stronger than a single application of skin adhesive (n = 5) (p < 0.01). We have tentatively named the wound closure in which a skin adhesive and reinforcement material were combined the Reinforcing Combination Method. To obtain optimum conditions, further studies were done for sequence of application, type of reinforcement material, a number of layers, and width of the suture. The optimum condition for the reinforcement combination was established by applying one layer of skin adhesive over a skin closure tape, over one layer of skin adhesive, with a suture width of 4 cm. This reinforcement combination might be useful in clinical practice.

  15. Properties of textured silicon nitride ceramics produced by seeded tape-casting

    NASA Astrophysics Data System (ADS)

    Blanton, William T.

    Previous studies have shown preferred orientation in silicon nitride (Si3N4) imparts anisotropic properties to the material as a result of both anisotropy in the Si3N4 single crystal and the morphology of the Si3N4 grains. In this study, oriented Si3N4 materials were produced by the seeded tape-casting method wherein elongated beta-Si3N4 "seeds" were added to predominately alpha-Si3N4 ceramic slurries. The tapes were subsequently cut, stacked, laminated and hot-pressed with various stacking sequences. Through x-ray pole figure measurements and the calculation of the orientation distribution function (ODF), planar textures were measured when individual seeded layers were stacked randomly and an orthotropic texture was observed when the layers were aligned in the tape-casting direction. Maximum (002) multiples of a random distribution (MRD) for these two sample types were measured as 2.1 and 5.8, respectively. Comparing these results with those of unseeded samples indicates the beta-Si3N4 seeds are entirely responsible for the orthotropic texture recorded in the seeded tape-cast materials. Property anisotropy in the textured samples was found to be subtle. Indentation toughness measurements showed slightly higher values normal to the tape-casting plane (9.5 MPa·m1/2) compared to values in the tape-casting direction (8.0 MPa·m1/2) and the elastic constants normal to the tape-casting plane are generally lower than those in the tape-cast and cross-cast sample directions. The R-curve behavior of these samples showed only a slight increase in toughness with increasing crack length and no difference in toughness between sample types, all falling within the range of 4.5 to 5.8 MPa·m 1/2.

  16. Tongue adhesion in the horned frog Ceratophrys sp.

    NASA Astrophysics Data System (ADS)

    Kleinteich, Thomas; Gorb, Stanislav N.

    2014-06-01

    Frogs are well-known to capture elusive prey with their protrusible and adhesive tongues. However, the adhesive performance of frog tongues and the mechanism of the contact formation with the prey item remain unknown. Here we measured for the first time adhesive forces and tongue contact areas in living individuals of a horned frog (Ceratophrys sp.) against glass. We found that Ceratophrys sp. generates adhesive forces well beyond its own body weight. Surprisingly, we found that the tongues adhered stronger in feeding trials in which the coverage of the tongue contact area with mucus was relatively low. Thus, besides the presence of mucus, other features of the frog tongue (surface profile, material properties) are important to generate sufficient adhesive forces. Overall, the experimental data shows that frog tongues can be best compared to pressure sensitive adhesives (PSAs) that are of common technical use as adhesive tapes or labels.

  17. Tongue adhesion in the horned frog Ceratophrys sp.

    PubMed Central

    Kleinteich, Thomas; Gorb, Stanislav N.

    2014-01-01

    Frogs are well-known to capture elusive prey with their protrusible and adhesive tongues. However, the adhesive performance of frog tongues and the mechanism of the contact formation with the prey item remain unknown. Here we measured for the first time adhesive forces and tongue contact areas in living individuals of a horned frog (Ceratophrys sp.) against glass. We found that Ceratophrys sp. generates adhesive forces well beyond its own body weight. Surprisingly, we found that the tongues adhered stronger in feeding trials in which the coverage of the tongue contact area with mucus was relatively low. Thus, besides the presence of mucus, other features of the frog tongue (surface profile, material properties) are important to generate sufficient adhesive forces. Overall, the experimental data shows that frog tongues can be best compared to pressure sensitive adhesives (PSAs) that are of common technical use as adhesive tapes or labels. PMID:24921415

  18. Multi-filamentary REBCO tapes fabricated by scratching a buffer layer along the tape longitudinal direction

    NASA Astrophysics Data System (ADS)

    Kurihara, Chihaya; Fujita, Shinji; Nakamura, Naonori; Igarashi, Mitsunori; Iijima, Yasuhiro; Higashikawa, Kohei; Uetsuhara, Dai; Kiss, Takanobu; Iwakuma, Masataka

    2016-11-01

    A method for making multi-filamentary REBCO tapes by only scratching buffer layer was developed for coil application which requires accurate magnetic fields. By continuous Ic measurement, we found that our new multi-filamentary tape could provide almost equal Ic compared to conventional tapes. Then, using EBSD and RTR-SHPM methods, a divided structure of REBCO layer was surely confirmed. AC loss was also decreased. Furthermore, the result of delamination test of our new multi-filamentary tape showed enough mechanical property. As a result, we have succeeded in developing 100 m class multi-filamentary tape for superconducting coil.

  19. Bandaging and taping considerations for the dancer.

    PubMed

    Ewalt, Katherine L

    2010-01-01

    Although widely disputed, bandaging and taping techniques are common practice in sports medicine. This article reviews literature related to the efficacy of bandaging and taping procedures and their role in sport and dance medicine. It further examines dance-specific application principles, and outlines selected techniques for treatment of common dance-related pathologies.

  20. 21 CFR 886.1905 - Nystagmus tape.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... OPHTHALMIC DEVICES Diagnostic Devices § 886.1905 Nystagmus tape. (a) Identification. Nystagmus tape is a device that is a long, narrow strip of fabric or other flexible material on which a series of objects are... nystagmus (abnormal and irregular eye movements) and to test for blindness. (b) Classification. Class...

  1. 21 CFR 886.1905 - Nystagmus tape.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... OPHTHALMIC DEVICES Diagnostic Devices § 886.1905 Nystagmus tape. (a) Identification. Nystagmus tape is a device that is a long, narrow strip of fabric or other flexible material on which a series of objects are... nystagmus (abnormal and irregular eye movements) and to test for blindness. (b) Classification. Class...

  2. The Effect of the Kinesio Taping and Spiral Taping on Menstrual Pain and Premenstrual Syndrome

    PubMed Central

    Lim, Chaegil; Park, Yongnam; Bae, Youngsook

    2013-01-01

    [Purpose] The purpose of this study was to compare the effects of Kinesio taping and spiral taping on menstrual pain and premenstrual syndrome, to investigate the efficacy of the two types of taping as methods for alleviating menstrual pain and premenstrual syndrome. [Subjects and Methods] The subjects of this study were 34 unmarried women. The subjects were randomly divided into a Kinesio taping group, a spiral taping group and a control group. Subjects with a regular menstrual cycle underwent taping a total of six times; twice a week for about three weeks, starting from 14 days before menstruation and continuing until its end. Degrees of menstrual pain and premenstrual syndrome were measured before the application of taping. [Results] The results revealed that Kinesio taping had significant effects on menstrual pain, while spiral taping was effective at alleviating both menstrual pain and premenstrual syndrome. [Conclusion] Both taping methods before menstruation brought significant relief to menstrual pain, which suggests that spiral taping is an effective method of alleviating premenstrual symptoms. PMID:24259847

  3. Mechanical stabilization of BSCCO-2223 superconducting tapes

    SciTech Connect

    King, C.G.; Grey, D.A.; Mantone, A.

    1996-12-31

    A system to provide mechanical stabilization to high temperature BSCCO-2223 superconducting tape by laminating 0.081 mm thick, spring hard, copper foil to both sides with lead-tin eutectic solder has been successfully optimized. This system has been applied as a method to create a strong, windable composite from pure silver BSCCO tapes with a minimum of critical current (I{sub c}) degradation. The {open_quotes}as received{close_quotes} conductor is evaluated for physical consistency of width and thickness over the 3000 meters that were later strengthened, insulated and wound into a demonstration coil. Electrical degradation in the strengthened tape as a result of lamination was found to average 24 percent with a range from 4 to 51 percent. This was less than the degradation that would have occurred in an unstrengthened tape during subsequent insulation and coil winding processes. Additional work was performed to evaluate the mechanical properties of the strengthened tapes. The copper can double the ultimate tensile strength of the pure silver tapes. Additionally, pure silver and dispersion strengthened silver matrix tapes are laminated with 0.025 mm thick copper and 304 stainless steel foil to investigate minimization of the cross sectional area of the strengthening component. The stainless steel can increase the UTS of the pure silver tapes sixfold. Metallography is used to examine the laminate and the conductor. Mechanical properties and critical currents of these tapes are also reported both before and after strengthening. The I{sub c} is also measured as a function of strain on the laminated tapes.

  4. Demonstration project cuts red tape

    NASA Astrophysics Data System (ADS)

    Katzoff, Judith A.

    Results from a demonstration project aimed at cutting red tape in federal grants for basic research at universities are "very encouraging" so far, according to Don I. Phillips, executive director of the Government-University-Industry Research Roundtable. The roundtable is coordinating the experimental effort, with the participation of five major federal agencies as well as the Florida state university system and the University of Miami (a private institution in Coral Gables, Fla.).Under the project, special conditions apply to grants from the participating agencies to individual researchers at the participating universities: Investigators do not have to ask the agency's permission for changes in budget allocations, purchases of permanent equipment, or foreign travel. Grant money can be spent up to a year after the grant ends without a special request. Under this plan, researchers, with agency approval, can also ask to have their entire research program covered as a single administrative entity, rather than as several individual projects.

  5. Processing and properties of Ag/BSCCO PIT tapes containing different proportions of silver metal powder

    NASA Astrophysics Data System (ADS)

    dos Santos, Dayse I.; Rodrigues, Durval; Rubo, Elisabete Ap. A.; Cursino, Eliana

    2004-08-01

    Monofilamentary tapes (150 μm thickness) were prepared by swaging and rolling silver tubes containing the Bi:2212 ceramic (granulation below 20 μm) and the silver powder (about 0.8 μm). The study has been made, among other samples, on tapes with nominal proportions of 0, 10 and 20 wt.% of silver. The samples were characterized by SEM, and by electrical measurements under varying applied magnetic field. The measurements of Jc showed that the addition of 10 wt.% silver powder is very beneficent to this property, doubling the obtained values at 60 K, while the 20 wt.% tape presented very low Jc. The tape with no silver content showed to have a Jc as high as 2.2 × 10 5 A/cm 2, at 4.2 K, zero applied magnetic field.

  6. The spectroscopic detection of drugs of abuse in fingerprints after development with powders and recovery with adhesive lifters

    NASA Astrophysics Data System (ADS)

    West, Matthew J.; Went, Michael J.

    2009-01-01

    The application of powders to fingerprints has long been established as an effective and reliable method for developing latent fingerprints. Fingerprints developed in situ at a crime scene routinely undergo lifting with specialist tapes and are then stored in evidence bags to allow secure transit and also to preserve the chain of evidence. In a previous study we have shown that exogenous material within a fingerprint can be detected using Raman spectroscopy following development with powders and lifting with adhesive tapes. Other reports have detailed the use of Raman spectroscopy to the detection of drugs of abuse in latent fingerprints including cyanoacrylate-fumed fingerprints. This study involves the application of Raman spectroscopy for the analysis of drugs of abuse in latent fingerprints for fingerprints that had been treated with powders and also subsequently lifted with adhesive tapes. Samples of seized ecstasy, cocaine, ketamine and amphetamine were supplied by East Sussex Police and by the TICTAC unit at St. Georges Hospital Tooting. Contaminated fingerprints were deposited on clean glass slides. The application of aluminium or iron based powders to contaminated fingerprints did not interfere with the Raman spectra obtained for the contaminants. Contaminated fingerprints developed with powders and then lifted with lifting tapes were also examined. The combination of these two techniques did not interfere with the successful analysis. The lifting process was repeated using hinge lifters. As the hinge lifters exhibited strong Raman bands the spectroscopic analysis was more complex and an increase in the number of exposures to the detector allowed for improved clarification. Spectral subtraction was performed to remove peaks due to the hinge lifters using OMNIC software. Raman spectra of developed and lifted fingerprints recorded through evidence bags were obtained and it was found that the detection process was not compromised. Although the application of

  7. The spectroscopic detection of drugs of abuse in fingerprints after development with powders and recovery with adhesive lifters.

    PubMed

    West, Matthew J; Went, Michael J

    2009-01-01

    The application of powders to fingerprints has long been established as an effective and reliable method for developing latent fingerprints. Fingerprints developed in situ at a crime scene routinely undergo lifting with specialist tapes and are then stored in evidence bags to allow secure transit and also to preserve the chain of evidence. In a previous study we have shown that exogenous material within a fingerprint can be detected using Raman spectroscopy following development with powders and lifting with adhesive tapes. Other reports have detailed the use of Raman spectroscopy to the detection of drugs of abuse in latent fingerprints including cyanoacrylate-fumed fingerprints. This study involves the application of Raman spectroscopy for the analysis of drugs of abuse in latent fingerprints for fingerprints that had been treated with powders and also subsequently lifted with adhesive tapes. Samples of seized ecstasy, cocaine, ketamine and amphetamine were supplied by East Sussex Police and by the TICTAC unit at St. Georges Hospital Tooting. Contaminated fingerprints were deposited on clean glass slides. The application of aluminium or iron based powders to contaminated fingerprints did not interfere with the Raman spectra obtained for the contaminants. Contaminated fingerprints developed with powders and then lifted with lifting tapes were also examined. The combination of these two techniques did not interfere with the successful analysis. The lifting process was repeated using hinge lifters. As the hinge lifters exhibited strong Raman bands the spectroscopic analysis was more complex and an increase in the number of exposures to the detector allowed for improved clarification. Spectral subtraction was performed to remove peaks due to the hinge lifters using OMNIC software. Raman spectra of developed and lifted fingerprints recorded through evidence bags were obtained and it was found that the detection process was not compromised. Although the application of

  8. Effects of spiral taping applied to the neck and ankle on the body balance index

    PubMed Central

    Lee, Byung Hoon; Lee, Hye Rim; Kim, Kyeong Mi; Lee, Jeong Hun; Kim, Kyung Yoon

    2015-01-01

    [Purpose] This study was performed to investigate the changes in the body balance index when spiral taping is applied to the neck and ankle. The findings are expected to serve as evidence of the usefulness of taping the neck instead of the ankle when ankle taping is not feasible in clinical practice. [Subjects and Methods] Twenty healthy male students at A university were enrolled in this study. Balance measurements were made under three conditions: no intervention, ankle intervention and neck intervention. Static balance was measured with subjects’ eyes open and closed, and dynamic balance was measured with subjects’ eyes closed. [Results] There were significant differences in dynamic balance assessed by the Overall Balance Index (OBI), and the Anteroposterior Balance Index (ABI) with subjects’ eyes open when ankle or neck taping was applied compared to no intervention. The static balance (OBI) of subjects with eyes open showed significant differences from the no intervention condition in both the ankle and neck intervention. The static balance (OBI) with subjects’ eyes closed also showed significant differences in both the ankle and neck interventions compared to the no intervention condition. [Conclusion] Our results indicate that neck taping stimulates the somatic senses around the neck and increase proprioception, resulting in balance improvement similar to that elicited by ankle taping. Further studies with larger sample sizes various experimental conditions should be performed to more systematically and objectively elucidate the effects of neck taping. PMID:25642043

  9. Effect of filament twist on the structure and properties of Ag-sheathed Bi2223 tape

    NASA Astrophysics Data System (ADS)

    Nakamura, Y.; Kurihara, C.; Machida, T.; Inada, R.; Oota, A.

    2009-10-01

    Ag-sheathed Bi2223 tapes show good performances and are ready for many prototype applications. However, drastic reduction of AC loss is strongly required for practical AC power applications. To reduce the AC loss under AC external magnetic field, the introduction of filament twisting with high resistive barrier is effective, but the filament twisting tends to decrease the Jc value. This decrease in Jc is a problem to balance low AC loss with high Ic value. In this study, the effect of filament twisting on the microstructure and Jc property was investigated to overcome the Jc reduction. The Bi2223 tapes sheathed with Ag-Cu alloy were fabricated with a standard PIT method. Although the formation of Bi2223 phase was not affected by filament twisting from the XRD analysis and SEM observation, the Jc values of the twisted tapes decreased about 30% compared to that of non-twisted tape. In the case of the same twist pitch, the sample rolled under large pass reduction ratio showed relatively high Jc value. This high Jc would be caused by the high aspect ratio of the filament of those tapes, in which the grain alignment along the filament interface would be well. On the other hand, a reason for the Jc reduction of twist tapes is proposed to be the misorientation at grain boundaries of Bi2223 grains in the transference region near the edges of the tape, where the filaments move up and down in the thickness direction.

  10. Delamination behaviour of GdBCO coated conductor tapes under transverse tension

    NASA Astrophysics Data System (ADS)

    Gorospe, A.; Nisay, A.; Dizon, J. R.; Shin, H. S.

    2013-11-01

    The electromechanical property behaviour of 2G coated conductor (CC) tapes fabricated by multi-layer deposition process both in the in-plane and transverse direction should be understood. The CC tapes are used in the fabrication of epoxy resin-impregnated coils. In such case, the Lorentz force due to the high magnetic field applied as well as the thermal stress due to the difference in coefficient of thermal expansion (CTE) among constituent layers during cooling to cryogenic temperature will induce transversely applied load to the surface of CC tapes in coils. Hence, the CC tape should have a good mechanical property in the transverse direction in order to maintain its superior performance under magnetic field. In this study, a test frame which gives precisely aligned transverse load was devised. Using the fixture, the delamination behaviours including the delamination strength of the GdBCO CC tapes under transverse tensile loading were investigated. Large variation on the delamination strength of the CC tapes was recorded and might have resulted from the slit edge effect and the inhomogeneity of the CC tapes. The Ic degradation behaviour under transverse load was related to the location where delamination occurred in the sample.

  11. Design and implementation of scalable tape archiver

    NASA Technical Reports Server (NTRS)

    Nemoto, Toshihiro; Kitsuregawa, Masaru; Takagi, Mikio

    1996-01-01

    In order to reduce costs, computer manufacturers try to use commodity parts as much as possible. Mainframes using proprietary processors are being replaced by high performance RISC microprocessor-based workstations, which are further being replaced by the commodity microprocessor used in personal computers. Highly reliable disks for mainframes are also being replaced by disk arrays, which are complexes of disk drives. In this paper we try to clarify the feasibility of a large scale tertiary storage system composed of 8-mm tape archivers utilizing robotics. In the near future, the 8-mm tape archiver will be widely used and become a commodity part, since recent rapid growth of multimedia applications requires much larger storage than disk drives can provide. We designed a scalable tape archiver which connects as many 8-mm tape archivers (element archivers) as possible. In the scalable archiver, robotics can exchange a cassette tape between two adjacent element archivers mechanically. Thus, we can build a large scalable archiver inexpensively. In addition, a sophisticated migration mechanism distributes frequently accessed tapes (hot tapes) evenly among all of the element archivers, which improves the throughput considerably. Even with the failures of some tape drives, the system dynamically redistributes hot tapes to the other element archivers which have live tape drives. Several kinds of specially tailored huge archivers are on the market, however, the 8-mm tape scalable archiver could replace them. To maintain high performance in spite of high access locality when a large number of archivers are attached to the scalable archiver, it is necessary to scatter frequently accessed cassettes among the element archivers and to use the tape drives efficiently. For this purpose, we introduce two cassette migration algorithms, foreground migration and background migration. Background migration transfers cassettes between element archivers to redistribute frequently accessed

  12. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... of surgical dressing without a disinfectant. The device is used to cover and protect wounds, to hold together the skin edges of a wound, to support an injured part of the body, or to secure objects to...

  13. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... of surgical dressing without a disinfectant. The device is used to cover and protect wounds, to hold together the skin edges of a wound, to support an injured part of the body, or to secure objects to...

  14. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... of surgical dressing without a disinfectant. The device is used to cover and protect wounds, to hold together the skin edges of a wound, to support an injured part of the body, or to secure objects to...

  15. Non-destructive evaluation of longitudinal uniformity for twisted Bi2223 tapes using scanning Hall-probe microscopy

    NASA Astrophysics Data System (ADS)

    Inada, R.; Makihara, T.; Araki, Y.; Baba, S.; Nakamura, Y.; Oota, A.; Sakamoto, S.; Li, C. S.; Zhang, P. X.

    2010-11-01

    In general, shorter filament twisting should be required for substantial AC loss reduction of Bi2223 tapes under an AC external field. However, the longitudinal uniformity of both transport property and wire structure of a tightly twisted tape could be easily deteriorated. To qualify the uniformity of twisted tape, simple and non-destructive evaluation techniques should be urgently required. In this study, we non-destructively measured the remanent magnetic field distributions for twisted Bi2223 tapes using scanning Hall-probe microscopy (SHM) with an active area of 50 μm × 50 μm. Twist pitch lengths of the tapes used for the measurements were 10 mm and 6 mm. After the tape was fixed on the sample holder at 77 K and zero fields, the magnetic field in perpendicular to the broader face of the tape was applied by a rectangular permanent magnet moving along a tape length. After removing the field, the distributions of remanent field Brz in perpendicular to tape surface were measured by SHM at a fixed distance of 0.5 mm away from a tape surface. For tightly twisted tape with twist pitch length of 6 mm, the longitudinal uniformity of Brz and transport critical current Ic were degraded remarkably and the local positions at which Brz greatly drops were well corresponding to low Ic region. It was also confirmed that the defects in filaments caused by tight twisting strongly affect on the intensity and shape of Brz profiles. The results suggest that SHM has the potential for simple and non-destructive characterization to qualify the longitudinal uniformity of twisted tapes.

  16. Shuttle active thermal control system development testing. Volume 7: Improved radiator coating adhesive tests

    NASA Technical Reports Server (NTRS)

    Reed, M. W.

    1973-01-01

    Silver/Teflon thermal control coatings have been tested on a modular radiator system projected for use on the space shuttle. Seven candidate adhesives have been evaluated in a thermal vacuum test on radiator panels similar to the anticipated flight hardware configuration. Several classes of adhesives based on polyester, silicone, and urethane resin systems were tested. These included contact adhesives, heat cured adhesives, heat and pressure cured adhesives, pressure sensitive adhesives, and two part paint on or spray on adhesives. The coatings attached with four of the adhesives, two silicones and two urethanes, had no changes develop during the thermal vacuum test. The two silicone adhesives, both of which were applied to the silver/Teflon as transfer laminates to form a tape, offered the most promise based on application process and thermal performance. Each of the successful silicone adhesives required a heat and pressure cure to adhere during the cryogenic temperature excursion of the thermal-vacuum test.

  17. Tape cast bioactive metal-ceramic laminates for structural application

    NASA Astrophysics Data System (ADS)

    Clupper, Daniel Christopher

    Bioglass 45S5, is a silica based glass which is able to rapidly form strong bonds with bone and soft tissue in vivo. It is used clinically to replace damaged ear ossicles and in dental surgery to help maintain the structural integrity of the jaw bone. The goal of the research was to demonstrate that Bioglass can be toughened by lamination with metallic layers while maintaining bioactivity. Improvement of the mechanical properties of Bioglass 45SS would allow for additional clinical applications, such as fracture fixation plates, or vertebral spacers. Bioglass 45S5 was tape cast and laminated with clinically relevant metals (316L, stainless steel and titanium) as well as copper in an effort to demonstrate that the effective toughness, or area under the load-deflection diagram can be increased significantly through ductile layer lamination. The average strength of monolithic tape cast sintered Bioglass was as high as 150 MPa and the toughness measured approximately 1.0 MPa m1/2. Copper-Bioglass laminates clearly demonstrated the toughening effect of metal layers on tape cast sintered Bioglass 45S5. Steel-Bioglass laminates, although less tough than the copper-Bioglass laminates, showed higher strengths. In vitro bioactivity tests of both titanium and steel Bioglass laminates showed the formation of mature and thick hydroxyapatite layers after 24 hours in Tris buffer solution. Under the standard test conditions, the bioactivity of monolithic tape cast sintered Bioglass increased with increasing sintering temperature. For samples sintered at 1000°C, thick crystalline layers of hydroxyapatite formed within 24 hours in Tris buffer solution. The bioactivity of these samples approached that of amorphous bulk Bioglass. Samples processed at 800°C were able to form thick crystalline hydroxyapatite layer after 24 hours when the test solution volume was increased by eight times.

  18. Ferromagnetic resonance of particulate magnetic recording tapes

    NASA Astrophysics Data System (ADS)

    Netzelmann, U.

    1990-08-01

    The room-temperature ferromagnetic resonance (FMR) spectra of γ-Fe2O3, CrO2, and barium ferrite particulate magnetic recording tapes have been measured at microwave frequencies of 9.35 and 35 GHz for various orientations of the static and high-frequency magnetic fields with respect to the tape. For CrO2 tapes, the influence of the width of the angular distribution of the particle orientations on the FMR spectra has been studied from the nearly isotropic case up to the highly oriented case. Hysteretic behavior for a CrO2 tape as well as the effect of tape calendering for a γ-Fe2O3 tape has been observed by FMR. Experimental results are found to be in reasonable agreement with results of theoretical calculations based on a model of an ellipsoidal single-domain particle with both shape and magnetocrystalline anisotropy. Magnetostatic interaction inside the magnetic film has been introduced by expressing the total magnetostatic energy as a combination of a part dependent on particle shape and a part dependent on the shape of the tape. As a result of a comparison of experimental data with calculated data from the model, the magnetocrystalline easy axis of the CrO2 particles is found to be parallel with the particle axis.

  19. Effect of 3 Different Applications of Kinesio Taping Denko® on Electromyographic Activity: Inhibition or Facilitation of the Quadriceps of Males During Squat Exercise.

    PubMed

    Serrão, Júlio C; Mezêncio, Bruno; Claudino, João G; Soncin, Rafael; Miyashiro, Pedro L Sampaio; Sousa, Eric P; Borges, Eduardo; Zanetti, Vinícius; Phillip, Igor; Mochizuki, Luiz; Amadio, Alberto C

    2016-09-01

    Kinesio taping consists of a technique which uses the application of an elastic adhesive tape. It has become a widely used rehabilitation modality for the prevention and treatment of musculoskeletal disorders. The objective of this study was to verify the effect of the application of Kinesio Taping Denko(®) in three conditions (facilitation, inhibition, and placebo) on the electromyographic activity of the quadriceps and hamstrings muscles on facilitating or inhibiting the muscle function and on the perceived exertion during the barbell back squat exercise in healthy male subjects.

  20. An automatic monitor of formaldehyde in air by a monitoring tape method.

    PubMed

    Nakano, N; Nagashima, K

    1999-06-01

    An automatic monitor has been developed for measuring formaldehyde in air using a sensitive tape for formaldehyde. It is based on the color change of the tape on reaction with formaldehyde. The porous cellulose tape, containing silica gel as an absorbent and impregnated with the processing solution containing hydroxylamine sulfate, Methyl Yellow (pH indicator; pH 2.9-4.0, red-yellow), glycerin and methanol, was found to be a highly sensitive means of detecting formaldehyde and maintains a stable sensitivity. When the tape was exposed to a sample of air containing formaldehyde, the color of the tape changed from yellow to red. The degree of color change was proportional to the concentration of formaldehyde at a constant sampling time and flow rate, and it could be recorded by measuring the intensity of reflected light (555 nm). The tape could be used to detect down to 0.08 ppm (World Health Organization standard) of formaldehyde with a sampling time of 30 min and a flow rate of 100 mL min-1. Reproducibility tests showed that the relative standard deviation of response (n = 10) was 3.8% for 0.1 ppm formaldehyde. The monitor is simple, specific, capable of unattended operation and is recommended for both laboratory and field operation.

  1. Optimal heating trajectories of controlling green tapes of YSZ electrolyte deformation using TMA during thermal processing

    NASA Astrophysics Data System (ADS)

    Liau, Leo Chau-Kuang; Chen, Chung-Chun

    The optimal heating trajectories to minimize the time required for the organic additives removal in yttria-stabilized zirconia (YSZ) green tapes were determined using a dynamic optimization method. The removal process model was described by the mass transport of the volatile gas evolved from the thermal decomposition of the organic additives inside the tapes and the kinetics of the decomposition. The pressure buildup of the sample tapes formed by the volatile gas can be estimated by a numerical simulation method; meanwhile, the deformation (strain) of the tape caused by the pressure buildup was measured by a thermal mechanical analyzer (TMA) during the thermal processing. Results show that the formation of the maximum pressure buildup at the center of the cubic tape is influenced by the sample size and heating conditions. In addition, the dynamic strain at the center of the sample measured by TMA agrees with the formation of the pressure buildup estimated by the numerical calculation. Moreover, the optimal heating trajectories determined by the dynamic optimization scheme with the constraint of the formation of the maximum pressure buildup were verified from the tape deformation analysis by the TMA tests.

  2. Kinesio Taping Fundamentals for the Equine Athlete.

    PubMed

    Molle, Sybille

    2016-04-01

    The Kinesio taping method was developed in Japan for use in humans in 1979. The use of complementary therapies is becoming common in equine athletes and the discovery of Kinesio taping potential brought it into the animal world. Kinesio taping can be used to treat a wide range of clinical conditions, from tendon injuries to neurologic disorders and from muscle contractures to postural insufficiencies. Its use in veterinary medicine is promising, but relies heavily on evidence-based clinical reports. Further scientific research is needed to fully understand the real effectiveness of application.

  3. High-Density-Tape Casting System

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr.

    1987-01-01

    Centrifuge packs solids from slurry into uniform, dense layer. New system produces tapes of nearly theoretical packing density. Centrifugal system used to cast thin tapes for capacitors, fuel cells, and filters. Cylindrical rotary casting chamber mounted on high-speed bearings and connected to motor. Liquid for vapor-pressure control and casting slurry introduced from syringes through rotary seal. During drying step, liquid and vapor vented through feed tubes or other openings. Laminated tapes produced by adding more syringes to cast additional layers of different materials.

  4. Ankle inversion taping using kinesiology tape for treating medial ankle sprain in an amateur soccer player

    PubMed Central

    Lee, Sun-Min; Lee, Jung-Hoon

    2015-01-01

    [Purpose] The purpose of this study was to report the effects of ankle inversion taping using kinesiology tape in a patient with a medial ankle sprain. [Subject] A 28-year-old amateur soccer player suffered a Grade 2 medial ankle sprain during a match. [Methods] Ankle inversion taping was applied to the sprained ankle every day for 2 months. [Results] His symptoms were reduced after ankle inversion taping application for 2 months. The self-reported function score, the reach distances in the Star Excursion Balance Test, and the weight-bearing ankle dorsiflexion were increased. [Conclusion] This study showed that ankle inversion taping using kinesiology tape may be an effective therapy for a patient with a medial ankle sprain. PMID:26311991

  5. Effects of ankle eversion taping using kinesiology tape in a patient with ankle inversion sprain

    PubMed Central

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    [Purpose] The aim of this study was to report the effects of ankle eversion taping using kinesiology tape on ankle inversion sprain. [Subject] The subject was a 21-year-old woman with Grade 2 ankle inversion sprain. [Methods] Ankle eversion taping was applied to the sprained left ankle using kinesiology tape for 4 weeks (average, 15 h/day). [Results] Ankle instability and pain were reduced, and functional dynamic balance was improved after ankle eversion taping for 4 weeks. The Cumberland Ankle Instability Tool score and reach distances in the Y-Balance and lunge tests were increased. [Conclusion] Repeated ankle eversion taping may be an effective treatment intervention for ankle inversion sprain. PMID:27064668

  6. Study on the limiting factor of critical current in Ag-Bi2223 tapes

    NASA Astrophysics Data System (ADS)

    Liu, Y.; Ding, S. Y.; Luo, H.; Leng, X.; Lin, J. W.

    2003-04-01

    The silver sheathed tapes of Ag-Bi 2- xPb xSr 2Ca 2-Cu 3O 7- y (Ag-Bi2223) were fabricated by usual process. The limiting factor of the critical current density jc of the tapes was studied. V- I characteristic was performed for the tapes immersed in liquid nitrogen with and without magnetic fields. Hysteresis loop of V- I curve was observed. A model based on polycrystalline superconductors was proposed to account for this kind of hysteresis. The result shows that in our Ag-Bi2223 tapes the weak link is the key factor limiting the global critical current. The measurement of V- I loop can be an effective method to check whether there exist harmful weak links in polycrystalline samples.

  7. New energy storage concept uses tapes

    NASA Technical Reports Server (NTRS)

    Gruber, A.; Kafesjian, R. R.

    1966-01-01

    Energy storage system uses movable permeable tapes with cathode and electrolyte material that is drawn across an anode to produce electric power. The system features long shelf life, high efficiency, and flexible operation.

  8. Video Tape and the Mentally Retarded

    ERIC Educational Resources Information Center

    Weisbord, H. F.

    1972-01-01

    Three uses of video tape recordings with the mentally retarded; discussed briefly are staff training or teacher education, parental involvement in the child's education, and therapeutic uses by psychiatrists and psychologists. (CB)

  9. Operating time meter for tape recorder

    NASA Astrophysics Data System (ADS)

    Ganzburg, M.; Dyuffel, O.

    1985-03-01

    As an alternative to standard tape counters for popular tape recorders, a photo-electric device for measuring operating time so as to give a precise reading of expended and available operating time. The device consists of two optical components in a slotted cylinder attached to the rubberized free-wheeling tension wheel. The first, third and fourth discharge circuits have a calculation coefficient of 10, the second, of 6. Technical features are diagrammed and described. The three components include the mechanical tension wheel and the plate on which the light- and photodiodes are mounted, the basic meter plate and light diode indicators and related components. If quality parts are properly mounted, no calibration is required. Features of mechanical tape regulation permitting smooth monitoring of tape movement may make the photoelectric device described unnecessary.

  10. Urinary incontinence - tension-free vaginal tape

    MedlinePlus

    ... place) Damage to the urethra, bladder, or vagina Erosion of the tape into surrounding normal tissues (urethra ... told to take with a small sip of water. Your doctor or nurse will tell you when ...

  11. User's guide and tape specification for ERB 7 DELMAT

    NASA Technical Reports Server (NTRS)

    Ardanuy, P.; Penn, L.

    1985-01-01

    Guidance is provided to the DELMAT user in the areas of purpose, use and limitations of DELMAT tapes and software. The DELMAT tape specifications is also provided. The ERB-7, ERB MAT and tape characteristics applicable to the DELMAT tapes are also summarized.

  12. Structural modeling of HTS tapes and cables

    NASA Astrophysics Data System (ADS)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2016-12-01

    Structural finite element analysis (FEA) has been used as an insightful tool to investigate the electromechanical behavior of HTS REBCO tapes and twisted stacked-tape cables under tension, torsion, bending and combined loads. A novel technique was developed for modeling the layered composite structure of the 2G tapes with structural solid-shell elements in ANSYS®. The FEA models produced detailed strain information for the REBCO superconducting layer which was then paired with an analytical model to predict the critical current performance of the 2G HTS tapes under various loads. Two commercially available HTS tapes (SuperPower and SuNAM) under tension, torsion and combined tension-torsion were first analyzed with FEA and compared with available experimental results at 77 K. A sharp critical current degradation was experienced at the yield strength of the tapes under tension and below a 100 mm twist-pitch under torsion. Combined tension-torsion loads had a more gradual degradation of critical current for twist-pitches of 115 mm or shorter but had a negligible difference compared to pure tension for longer twist-pitches. Using the structural solid-shell technique for modeling 2G tapes in ANSYS®, an FEA methodology for simulating full scale three-dimensional HTS stacked-tape cables under pure bending was created. A model of a Twisted-Stacked Tape Cable (TSTC), a configuration first proposed at MIT, was initially developed and then adapted to the slotted-core HTS Cable-In-Conduit Conductor produced by the ENEA laboratory in Italy. The numerical axial strain of the HTS REBCO tapes within the cables as calculated by FEA were found to agree with an analytical model for two cases: perfect-slip (frictionless) and no-slip (bonded). The ENEA CICC model was also compared with recent experimental critical current data at 77 K and was found to match best using a low friction coefficient of 0.02 indicating that the tapes within the cable freely slide with respect to each other

  13. Effects of ankle balance taping with kinesiology tape for a patient with chronic ankle instability.

    PubMed

    Kim, Byeong-Jo; Lee, Jung-Hoon; Kim, Chang-Tae; Lee, Sun-Min

    2015-07-01

    [Purpose] To report the effects of ankle balance taping for a patient with chronic ankle instability (CAI). [Subject] A 33-year-old man with a 10 year history of chronic ankle stability. [Methods] ABT with kinesiology tape was performed for 2 months (average, 16 h/day) around the right ankle. [Results] At the end of two months, no ankle instability was noted when ascending and descending the stairs, jumping, turning, operating the pedals while driving, and lifting heavy objects. [Conclusion] The repeated use of kinesiology tape in ankle balance taping may be an effective treatment for recovering the ankle stability of patients with chronic ankle instability.

  14. Read/write head for a magnetic tape device having grooves for reducing tape floating

    DOEpatents

    Aoki, Kenji

    2005-08-09

    A read/write head for a magnetic tape includes an elongated chip assembly and a tape running surface formed in the longitudinal direction of the chip assembly. A pair of substantially spaced parallel read/write gap lines for supporting read/write elements extend longitudinally along the tape running surface of the chip assembly. Also, at least one groove is formed on the tape running surface on both sides of each of the read/write gap lines and extends substantially parallel to the read/write gap lines.

  15. Effects of ankle balance taping with kinesiology tape for a patient with chronic ankle instability

    PubMed Central

    Kim, Byeong-Jo; Lee, Jung-Hoon; Kim, Chang-Tae; Lee, Sun-Min

    2015-01-01

    [Purpose] To report the effects of ankle balance taping for a patient with chronic ankle instability (CAI). [Subject] A 33-year-old man with a 10 year history of chronic ankle stability. [Methods] ABT with kinesiology tape was performed for 2 months (average, 16 h/day) around the right ankle. [Results] At the end of two months, no ankle instability was noted when ascending and descending the stairs, jumping, turning, operating the pedals while driving, and lifting heavy objects. [Conclusion] The repeated use of kinesiology tape in ankle balance taping may be an effective treatment for recovering the ankle stability of patients with chronic ankle instability. PMID:26311206

  16. Thermally Conductive Tape Based on Carbon Nanotube Arrays

    NASA Technical Reports Server (NTRS)

    Kashani, Ali

    2011-01-01

    To increase contact conductance between two mating surfaces, a conductive tape has been developed by growing dense arrays of carbon nanotubes (CNTs, graphite layers folded into cylinders) on both sides of a thermally conductive metallic foil. When the two mating surfaces are brought into contact with the conductive tape in between, the CNT arrays will adhere to the mating surface. The van der Waals force between the contacting tubes and the mating surface provides adhesion between the two mating surfaces. Even though the thermal contact conductance of a single tube-to-tube contact is small, the tremendous amount of CNTs on the surface leads to a very large overall contact conductance. Interface contact thermal resistance rises from the microroughness and the macroscopic non-planar quality of mating surfaces. When two surfaces come into contact with each other, the actual contact area may be much less than the total area of the surfaces. The real area of contact depends on the load, the surface roughness, and the elastic and inelastic properties of the surface. This issue is even more important at cryogenic temperatures, where materials become hard and brittle and vacuum is used, which prevents any gas conduction through the interstitial region. A typical approach to increase thermal contact conductance is to use thermally conducting epoxies or greases, which are not always compatible with vacuum conditions. In addition, the thermal conductivities of these compounds are often relatively low. The CNTs used in this approach can be metallic or semiconducting, depending on the folding angle and diameter. The electrical resistivity of multiwalled carbon nanotubes (MWCNTs) has been reported. MWCNTs can pass a current density and remain stable at high temperatures in air. The thermal conductivity of a MWCNT at room temperature is measured to be approximately 3,000 W/m-K, which is much larger than that of diamond. At room temperature, the thermal conductance of a 0.3 sq cm

  17. Program Documentation Report: STD Tape Copy Programs,

    DTIC Science & Technology

    Berman Model 9040 STD probe and 1014 data logger. The programs are written in FORTRAN IV and IBM 360 ASSEMBLAR COMPUTER LANGUAGES. Data tapes from the... STD in 7 track format are read in ASSEMBLAR Language and a 9 track FORTRAN readable tape produced. Printouts from the programs record the number of data points recovered and also list the bad data points (if any). (Author)

  18. FGGE/ERBM tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The Nimbus-7 FGGE/ERBM tape contains 27 ERB parameters which are extracted and reformatted from the Nimbus-7 ERB-MATRIX tape. There are four types of files on a FGGE/ERBM tape: a test file; tape-header file which describes the data set characteristics and the contents of the tape; a grid-descriptor file which contains the information of the ERB scanning channel target number and their associated latitude limits and longitude intervals; and one or more data files. A single end-of-file (EOF) tape mark is written after each file, and two EOF marks are written after the last data file on the tape.

  19. Effect of skin surface lipid on the skin permeation of lidocaine from pressure sensitive adhesives.

    PubMed

    Cheng, Y H; Hosoya, O; Sugibayashi, K; Morimoto, Y

    1994-12-01

    Pressure sensitive adhesives (PSA) tapes containing different concentrations of lidocaine were prepared by a general casting method using styrene-isoprene-styrene block copolymer, and the in vitro skin permeation of lidocaine from each tape was evaluated using diffusion cell and excised hairless rat skin. The skin permeation was proportionally increased by up to 40% lidocaine in the PSA tape and did not change after this concentration. Although the bending point of the steady-state flux via skin concentration curve was found at 40%, saturated concentration or solubility of lidocaine in the tape was estimated to be about 20% by differential scanning calorimetry (DSC) measurement. In addition, the steady-state flux of lidocaine through skin from water or silicone fluid suspension (92 or 120 micrograms/cm2.h, respectively) was very similar to those of 40, 50 and 60% tapes (105, 101 and 112 micrograms/cm2.h, respectively). Decrease in the concentration in tapes during the permeation experiment explained only part of these phenomena. To analyze them further, the drug free PSA tape with or without (control) skin surface lipid was affixed to 50% lidocaine PSA tape for 48 h, and the amount of lidocaine crystal in the layered tapes was measured by DSC. The amount was found to be lower in the lipid-containing tape than in the lipid-free tape, suggesting that skin surface lipid can dissolve lidocaine crystal or solid in PSA tape to decrease its thermodynamic activity. Thus it is important to follow the concentration and thermodynamic activity of lidocaine in PSA tape, skin and the interface between the two layers to exactly assess its skin permeation flux.

  20. Magnetic tape recorder for long operating life in space.

    NASA Technical Reports Server (NTRS)

    Bahm, E. J.; Hoffman, J. K.

    1971-01-01

    Magnetic tape recorders have long been used on satellites and spacecraft for onboard storage of large quantities of data. As satellites enter into commercial service, long operating life at high reliability becomes important. Also, the presently planned long-duration space flights to the outer planets require long-life tape recorders. Past satellite tape recorders have achieved a less than satisfactory performance record and the operating life of other spacecraft tape recorders has been relatively short and unpredictable. Most failures have resulted from malfunctions of the mechanical tape transport. Recent advances in electric motors and static memories have allowed the development of a new tape recorder which uses a very simple tape transport with few possible failure modes. It consists only of two brushless dc motors, two tape guides, and the recording heads. Relatively low tape tension, wide torque capability, and precise speed control facilitate design for mechanical reliability to match that of tape-recorder electronics.

  1. Enhanced adhesion by gecko-inspired hierarchical fibrillar adhesives.

    PubMed

    Murphy, Michael P; Kim, Seok; Sitti, Metin

    2009-04-01

    The complex structures that allow geckos to repeatably adhere to surfaces consist of multilevel branching fibers with specialized tips. We present a novel technique for fabricating similar multilevel structures from polymer materials and demonstrate the fabrication of arrays of two- and three-level structures, wherein each level terminates in flat mushroom-type tips. Adhesion experiments are conducted on two-level fiber arrays on a 12-mm-diameter glass hemisphere, which exhibit both increased adhesion and interface toughness over one-level fiber samples and unstructured control samples. These adhesion enhancements are the result of increased surface conformation as well as increased extension during detachment.

  2. Fatigue Behavior of Adhesively Bonded Joints. Volume I.

    DTIC Science & Technology

    1980-04-01

    electron spectroscopy (AES) and/or XPS scans. The adhesive used is FM-73M, a 2500F-cure tape from American Cyanamid of Havre de Grace, MD. This...34PABST Technical Bulletin No. 1", March 28, 1975. 14. FM 73 Adhesive Film, Data Bulletin BPT 20B, Cyanamid Bloom- ingdale Aerospace Products, Havre de...Joints," J. Appl. Mech. 11, 1944 , A17-A27. 29. Hart-Smith, L. C., Adhesive-Bonded Single-Lap Joints, NASA, CR-11236, January 1973. 30. Quarterly Progress

  3. Strategy for robot motion and path planning in robot taping

    NASA Astrophysics Data System (ADS)

    Yuan, Qilong; Chen, I.-Ming; Lembono, Teguh Santoso; Landén, Simon Nelson; Malmgren, Victor

    2016-06-01

    Covering objects with masking tapes is a common process for surface protection in processes like spray painting, plasma spraying, shot peening, etc. Manual taping is tedious and takes a lot of effort of the workers. The taping process is a special process which requires correct surface covering strategy and proper attachment of the masking tape for an efficient surface protection. We have introduced an automatic robot taping system consisting of a robot manipulator, a rotating platform, a 3D scanner and specially designed taping end-effectors. This paper mainly talks about the surface covering strategies for different classes of geometries. The methods and corresponding taping tools are introduced for taping of following classes of surfaces: Cylindrical/extended surfaces, freeform surfaces with no grooves, surfaces with grooves, and rotational symmetrical surfaces. A collision avoidance algorithm is introduced for the robot taping manipulation. With further improvements on segmenting surfaces of taping parts and tape cutting mechanisms, such taping solution with the taping tool and the taping methodology can be combined as a very useful and practical taping package to assist humans in this tedious and time costly work.

  4. Immediate and Delayed Effects of Forearm Kinesio Taping on Grip Strength

    PubMed Central

    Kouhzad Mohammadi, Hosein; Khademi Kalantari, Khosro; Naeimi, Sedighe Sadat; Pouretezad, Mohammad; Shokri, Esmaeil; Tafazoli, Mojdeh; Dastjerdi, Mahboobeh; Kardooni, Leila

    2014-01-01

    Background: Due to the fundamental role of gripping in most upper limb activities, grip strength promotion is a chief goal in the treatment of patients with upper limb musculoskeletal disorders. Kinesio taping is a novel and effective therapeutic technique believed to facilitate muscle contraction through stimulating mechanoreceptors and increasing the sensory feedback around the taped region. Objectives: The present study aimed to identify the best region (flexor, extensor and flexor/extensor regions) and time (immediate, 0.5, 1, 1.5, and 2 hours) of forearm Kinesio taping to obtain the maximum improvement in grip strength. Materials and Methods: In this longitudinal study, 40 healthy men and women (the mean age of 22.3 ± 2.19 years) were selected among students of Shahid Beheshti University of Medical Sciences, Tehran, Iran by simple, nonrandom sampling method. A dynamometer was used to measure grip strength immediately and every 30 minutes during the two hours after I-shaped application of tape (with 50% stretch) to the flexor, extensor, and flexor/extensor forearm muscles. Results: Grip strength was significantly increased in various muscle groups for males (P = 0.002) and females (P = 0.000) of the forearm and at different intervals for males (P = 0.000) and females (P = 0.000). Moreover, in both men and women, tape application to the extensor region provided greater grip strength compared to taping of the flexor and flexor/extensor regions (P = 0.000 for both). Furthermore, the maximum increase in grip strength were 0.5 (10.8% increase, P = 0.001) and 1.5 h (23.9% increase, P = 0.000) after taping in males and females, respectively. Conclusions: Taping the extensor region of forearm is recommended to achieve higher grip strength. Although grip strength increased at a slower pace in females than males, the final values were higher in women. PMID:25389492

  5. Effects of kinesio tape compared with non-elastic tape on hand grip strength.

    PubMed

    Kim, Ji Young; Kim, Seong Yeol

    2016-05-01

    [Purpose] Many assumptions have been made about taping and several studies have considered tape application methods; however, the true effect of taping on muscle strength remains unclear. Most previous studies compared application techniques using Kinesio tape (KT), but studies that compared muscle strength using non-elastic tape (NT) are limited. Moreover, no studies have applied KT and NT in the same way to assess grip strength in normal subjects. The purpose of this study was to evaluate the immediate effect of application of two tapes with different elastic properties on maximal grip strength in healthy adults. [Subjects and Methods] Twenty healthy adults were divided into two groups (KT and NT). Maximal grip strength was measured with a dynamometer. Forearm extensor muscles of the dominant hand were then taped and subjects were immediately asked to perform hand grip movement with maximum strength in the same standardized manner. [Results] In the KT group, maximal grip strength was significantly increased compared to the initial value; however, in the NT group, there was no significant difference in maximal grip strength. [Conclusion] This study suggests that only Kinesio tape can increase maximal grip strength immediately after application on the extensor region of the forearm.

  6. Effects of kinesio tape compared with non-elastic tape on hand grip strength

    PubMed Central

    Kim, Ji Young; Kim, Seong Yeol

    2016-01-01

    [Purpose] Many assumptions have been made about taping and several studies have considered tape application methods; however, the true effect of taping on muscle strength remains unclear. Most previous studies compared application techniques using Kinesio tape (KT), but studies that compared muscle strength using non-elastic tape (NT) are limited. Moreover, no studies have applied KT and NT in the same way to assess grip strength in normal subjects. The purpose of this study was to evaluate the immediate effect of application of two tapes with different elastic properties on maximal grip strength in healthy adults. [Subjects and Methods] Twenty healthy adults were divided into two groups (KT and NT). Maximal grip strength was measured with a dynamometer. Forearm extensor muscles of the dominant hand were then taped and subjects were immediately asked to perform hand grip movement with maximum strength in the same standardized manner. [Results] In the KT group, maximal grip strength was significantly increased compared to the initial value; however, in the NT group, there was no significant difference in maximal grip strength. [Conclusion] This study suggests that only Kinesio tape can increase maximal grip strength immediately after application on the extensor region of the forearm. PMID:27313372

  7. Krytox Lubrication Tape Study. [fluorinated lubricating oil for video tape recorders

    NASA Technical Reports Server (NTRS)

    Lee, F.

    1978-01-01

    The use of Krytox, a fluorinated oil, as a tape surface lubricant was studied for a wideband video tape recorder. In spite of the 5 to 1 head wear reduction credited to the surface lubricant, the resultant head life fell short of the 1500 hour goal.

  8. Simulated Space Environment Effects on the Blocking Force of Silicone Adhesive

    NASA Technical Reports Server (NTRS)

    Boeder, Paul; Mikatarian, Ron; Koontz, Steve; Albyn, Keith; Finckenor, Miria

    2005-01-01

    The International Space Station (ISS) solar arrays utilize MD-944 diode tape to protect the underlying diodes in the solar array panel circuit and also provide thermal conditioning and mechanical support. The diode tape consists of silicone pressure sensitive adhesive (Dow Coming QC-7725) with a protective Kapton over-layer. On-orbit, the Kapton over-layer will erode under exposure to atomic oxygen (AO) and the underlying exposed silicone adhesive will ultimately convert, under additional AO exposure, to a glass like silicate. The current operational plan is to retract ISS solar array P6 and leave it stored under load for a long duration (6 months or more) during ISS assembly. With the Kapton over-layer eroded away, the exposed silicone adhesive must not cause the solar array to stick to itself or cause the solar array to fail during redeployment. Previous testing by Lockheed-Martin Space Systems (LMSS) characterized silicone blocking following exposure to low energy atomic oxygen (AO) in an asher facility, but this is believed to be conservative. An additional series of tests was performed by the Environmental Effects Group at MSFC under direction from the ISS Program Office Environments Team. This test series included high energy AO (5 eV), near ultraviolet (NUV) radiation and ionizing radiation, singly and in combination. Additional samples were exposed to thermal energy AO (<0.1 ev) for comparison to the LMSS tests. Diode tape samples were exposed to each environment constituent individually, put under preload for seven days and then the resulting blocking force was measured using a tensile machine. Additional samples were exposed to AO, NUV and electrons in series and then put under long term (three to ten months) preload to determine the effect of preload duration on the resulting blocking force of the silicone-to-silicone bond. Test results indicate that high energy AO, ultraviolet radiation and electron ionizing radiation exposure all reduce the blocking

  9. Identification and comparison of electrical tapes using instrumental and statistical techniques: I. Microscopic surface texture and elemental composition.

    PubMed

    Goodpaster, John V; Sturdevant, Amanda B; Andrews, Kristen L; Brun-Conti, Leanora

    2007-05-01

    Comparisons of polyvinyl chloride electrical tape typically rely upon evaluating class characteristics such as physical dimensions, surface texture, and chemical composition. Given the various techniques that are available for this purpose, a comprehensive study has been undertaken to establish an optimal analytical scheme for electrical tape comparisons. Of equal importance is the development of a quantitative means for sample discrimination. In this study, 67 rolls of black electrical tape representing 34 different nominal brands were analyzed via scanning electron microscopy and energy dispersive spectroscopy. Differences in surface roughness, calendering marks, and filler particle size were readily apparent, including between some rolls of the same nominal brand. The relative amounts of magnesium, aluminum, silicon, sulfur, lead, chlorine, antimony, calcium, titanium, and zinc varied greatly between brands and, in some cases, could be linked to the year of manufacture. For the first time, quantitative differentiation of electrical tapes was achieved through multivariate statistical techniques, with 36 classes identified within the sample population. A single-blind study was also completed where questioned tape samples were correctly associated with known exemplars. Finally, two case studies are presented where tape recovered from an improvised explosive device is compared with tape recovered from a suspect.

  10. Torsion Strain Effects on Critical Currents of Hts Superconducting Tapes

    NASA Astrophysics Data System (ADS)

    Takayasu, Makoto; Minervini, Joseph V.; Bromberg, Leslie

    2010-04-01

    A torsional twist strain effect on the critical current of a thin HTS tape has been found to be well described by a longitudinal strain model taking into account the internal shortening compressive strains accompanied with the tensile longitudinal strains due to a torsional twist. The critical current of a twisted tape is given by the integration of the critical current densities corresponding to the strain distribution over the tape cross-section using axial strain data of the tape. The model is supported with experimental results of YBCO and BSCCO-2223 tapes. It has been also found that torsional twisting effects on the critical currents of a tape composing of the conventional lapped-tape cable and the twisted stacked-tape cable are described by the same equation as that of a twisted single tape.

  11. Adhesive plasters

    DOEpatents

    Holcombe, Jr., Cressie E.; Swain, Ronald L.; Banker, John G.; Edwards, Charlene C.

    1978-01-01

    Adhesive plaster compositions are provided by treating particles of Y.sub.2 O.sub.3, Eu.sub.2 O.sub.3, Gd.sub.2 O.sub.3 or Nd.sub.2 O.sub.3 with dilute acid solutions. The resulting compositions have been found to spontaneously harden into rigid reticulated masses resembling plaster of Paris. Upon heating, the hardened material is decomposed into the oxide, yet retains the reticulated rigid structure.

  12. Using magnetic tape technology for data migration

    NASA Technical Reports Server (NTRS)

    Therrien, David; Cheung, Yim-Ling

    1993-01-01

    Magnetic tape and optical disk library units (jukeboxes) are satisfying the demand for high-capacity cost-effective storage. The choice between optical disk and magnetic tape technology must take into account the cost limitations as well as the performance and reliability requirements of the user environment. Library units require data management software in order to function in an automated and user-transparent way. The most common data management applications are backup and recovery, data migration, and archiving. The medium access patterns that these applications create will be described. Since the most user visible application is data migration, a queue simulator was developed to model its performance against a variety of library units. The major subject of this paper is the design and implementation of this simulator as well as some simulation results. The relative cost and reliability of magnetic tape versus optical disk library units is presented for completeness.

  13. Digital optical tape: Technology and standardization issues

    NASA Technical Reports Server (NTRS)

    Podio, Fernando L.

    1996-01-01

    During the coming years, digital data storage technologies will continue an aggressive growth to satisfy the user's need for higher storage capacities, higher data transfer rates and long-term archival media properties. Digital optical tape is a promising technology to satisfy these user's needs. As any emerging data storage technology, the industry faces many technological and standardization challenges. The technological challenges are great, but feasible to overcome. Although it is too early to consider formal industry standards, the optical tape industry has decided to work together by initiating prestandardization efforts that may lead in the future to formal voluntary industry standards. This paper will discuss current industry optical tape drive developments and the types of standards that will be required for the technology. The status of current industry prestandardization efforts will also be discussed.

  14. Pressure Sensitive Tape in the Manufacture of Reusable Solid Rocket Motors

    NASA Technical Reports Server (NTRS)

    Champneys, Jeff

    2007-01-01

    ATK Launch Systems Inc. manufactures the reusable solid rocket motor (RSRM) for NASA's Space Shuttle program. They are used in pairs to launch the Space Shuttle. Pressure sensitive tape (PST) is used throughout the RSRM manufacturing process. A few PST functions are: 1) Secure labels; 2) Provide security seals; and 3) Protect tooling and flight hardware during various inert and live operations. Some of the PSTs used are: Cloth, Paper, Reinforced Teflon, Double face, Masking, and Vinyl. Factors given consideration for determining the type of tape to be used are: 1) Ability to hold fast; 2) Ability to release easily; 3) Ability to endure abuse; 4) Strength; and 5) Absence of adhesive residue after removal.

  15. Effect of filament twist and high resistive barrier on the properties of Ag-sheathed Bi2223 tape

    NASA Astrophysics Data System (ADS)

    Nakamura, Y.; Fujiwara, Y.; Nagaoka, A.; Machida, T.; Inada, R.; Oota, A.

    2010-11-01

    Although the introduction of filament twisting with high resistive barrier between the filaments is effective to reduce the AC loss, the Jc value of the tape was easily decreased by the filament twisting and insertion of high resistive barrier. This decrease in Jc is a problem to achieve low AC loss and high Ic tape. In this study, the effects of filament twist and high resistive barrier on the microstructure and Jc property were investigated to overcome the Jc reduction. The Bi2223 tapes with filament twist or oxide barrier were fabricated by powder-in-tube method. The Jc value of twist tape gradually decreased as decreasing the twist pitch, and the degree of Jc reduction was small in slim tape compared to wide tape. This reduction would attribute to the small actual cross sectional area of the filament perpendicular to the current direction because the filament has a tilt angle from the tape axis. On the other hand, the conversion ratio of Bi2223 became small as increasing the thickness of SZO barrier layer. Since the SZO barrier has less reactivity with 2223 filament, this suppression of the Bi2223 formation would not be caused by the formation of impurity phase but would be caused by the suppression of gas release from the filaments by oxide barrier. The conversion ratio of Bi2223 increased in the short sample where the gas could be released from the both end of the tape. These results suggest that the gas diffusion from filaments would be important for the formation of Bi2223. Hence, the use of slim tape for decreasing the tilt angle of the filament and keeping the diffusion path of gas from the filaments may improve the Jc value of twist and barrier tapes.

  16. Effects of Kinesio taping and Mcconnell taping on balance and walking speed of hemiplegia patients

    PubMed Central

    Choi, Yong-Kyu; Park, Young-Han; Lee, Jung-Ho

    2016-01-01

    [Purpose] The aim of this study was to evaluate the overlap effect of the PNF following the application of Kinesio taping and the McConnell taping, and also the impact of the taping application method on the balance and walking speed of the patients with stroke. [Subjects and Methods] Thirty-six patients who were diagnosed with hemiplegia due to stroke were selected as subjects of this study. They were randomly and evenly divided into experiment group 1 (Kinesio taping group), experiment group 2 (McConnell taping group), and the control group; each group had 12 patients. [Results] The Berg balance scale (BBS) was used to evaluate balance, and the ability in this study. A 10 m walking test (10MWT) was performed to measure the walking speed. Experiment group 1 showed a statistically significant improvement in balance and walking speed compared to experiment group 2, and the control group in week 4 and week 8. [Conclusion] Application of Kinesio taping had a more beneficial effect on the balance and walking speed than joint-fixation taping of the patients with stroke. PMID:27190448

  17. Adhesion enhancement of biomimetic dry adhesives by nanoparticle in situ synthesis

    NASA Astrophysics Data System (ADS)

    Díaz Téllez, J. P.; Harirchian-Saei, S.; Li, Y.; Menon, C.

    2013-10-01

    A novel method to increase the adhesion strength of a gecko-inspired dry adhesive is presented. Gold nanoparticles are synthesized on the tips of the microfibrils of a polymeric dry adhesive to increase its Hamaker constant. Formation of the gold nanoparticles is qualitatively studied through a colour change in the originally transparent substance and quantitatively analysed using ultraviolet-visible spectrophotometry. A pull-off force test is employed to quantify the adhesion enhancement. Specifically, adhesion forces of samples with and without embedded gold nanoparticles are measured and compared. The experimental results indicate that an adhesion improvement of 135% can be achieved.

  18. Textured substrate tape and devices thereof

    DOEpatents

    Goyal, Amit

    2006-08-08

    A method for forming a sharply biaxially textured substrate, such as a single crystal substrate, includes the steps of providing a deformed metal substrate, followed by heating above the secondary recrystallization temperature of the deformed substrate, and controlling the secondary recrystallization texture by either using thermal gradients and/or seeding. The seed is selected to shave a stable texture below a predetermined temperature. The sharply biaxially textured substrate can be formed as a tape having a length of 1 km, or more. Epitaxial articles can be formed from the tapes to include an epitaxial electromagnetically active layer. The electromagnetically active layer can be a superconducting layer.

  19. Elastic therapeutic tape: do they have the same material properties?

    PubMed Central

    Boonkerd, Chuanpis; Limroongreungrat, Weerawat

    2016-01-01

    [Purpose] Elastic therapeutic tape has been widely used for rehabilitation and treatment of sports injuries. Tapes with different elastic properties serve different treatment purposes with inappropriate tension reducing tape effectiveness. Many tapes are available in the market, but studies on tape properties are limited. The aim of this study was to examine the material properties of elastic therapeutic tape. [Subjects and Methods] Brands of elastic therapeutic tape included KinesioTex®, ATex, Mueller, 3M, and ThaiTape. The Material Testing System Insight® 1 Electromechanical Testing Systems was used to apply a tensile force on elastic therapeutic tape. Ten specimens of each brand were tested. Stress, load, and Young’s modulus at 25%, 50%, 75%, 100%, and maximum point were collected. One-way analysis of variance with post hoc testing was used to analyze tape parameters. [Results] Maximum elongation and Young’s modulus at all percentages were significantly different between brands. There were no differences in maximum load and maximum stress. [Conclusion] Mechanical properties are different for commercial elastic therapeutic tapes. Physiotherapists and other clinicians should be aware of mechanical tape properties to correctly apply kinesio tape. PMID:27190472

  20. Elastic therapeutic tape: do they have the same material properties?

    PubMed

    Boonkerd, Chuanpis; Limroongreungrat, Weerawat

    2016-04-01

    [Purpose] Elastic therapeutic tape has been widely used for rehabilitation and treatment of sports injuries. Tapes with different elastic properties serve different treatment purposes with inappropriate tension reducing tape effectiveness. Many tapes are available in the market, but studies on tape properties are limited. The aim of this study was to examine the material properties of elastic therapeutic tape. [Subjects and Methods] Brands of elastic therapeutic tape included KinesioTex(®), ATex, Mueller, 3M, and ThaiTape. The Material Testing System Insight(®) 1 Electromechanical Testing Systems was used to apply a tensile force on elastic therapeutic tape. Ten specimens of each brand were tested. Stress, load, and Young's modulus at 25%, 50%, 75%, 100%, and maximum point were collected. One-way analysis of variance with post hoc testing was used to analyze tape parameters. [Results] Maximum elongation and Young's modulus at all percentages were significantly different between brands. There were no differences in maximum load and maximum stress. [Conclusion] Mechanical properties are different for commercial elastic therapeutic tapes. Physiotherapists and other clinicians should be aware of mechanical tape properties to correctly apply kinesio tape.

  1. Short-Term Effects of Kinesio Taping and Cross Taping Application in the Treatment of Latent Upper Trapezius Trigger Points: A Prospective, Single-Blind, Randomized, Sham-Controlled Trial

    PubMed Central

    Halski, Tomasz; Ptaszkowski, Kuba; Słupska, Lucyna; Paprocka-Borowicz, Małgorzata; Dymarek, Robert; Taradaj, Jakub; Bidzińska, Gabriela; Marczyński, Daniel; Cynarska, Aleksandra; Rosińczuk, Joanna

    2015-01-01

    Kinesio taping (KT) may be a new treatment in patients with myofascial trigger points (MTrPs). A new method available for taping practitioners is cross taping (CT). The main objective was to determine how CT, KT, and medical adhesive tape (sham group) affect the subjective assessment of resting bioelectrical activity and pain of the upper trapezius muscle (UT) in patients with MTrPs. 105 volunteers were recruited to participate. The primary outcome was resting bioelectrical activity of UT muscle as assessed by surface electromyography (sEMG) in each group and pain intensity on a visual analog scale (VAS). Assessments were collected before and after intervention and after the 24-hours follow-up. No significant differences were observed in bioelectrical activity of UT between pre-, post-, and follow-up results. In three groups patients had significantly lower pain VAS score after the intervention (CT—p < 0.001, KT—p < 0.001, and sham—p < 0.01). The Kruskal-Wallis ANOVA showed no significant differences in almost all measurements between groups. The application of all three types of tapes does not influence the resting bioelectrical activity of UT muscle and may not lead to a reduction in muscle tone in the case of MTrPs. PMID:26491458

  2. An Inexpensive, Easy to Build Slide-Tape Programmer

    ERIC Educational Resources Information Center

    Lukas, Terrence

    1975-01-01

    This article discusses the construction and use of a slide/tape programer that is simple to build and use, costs a fraction of the cheapest commercial models, and can be used with any tape recorder/player. (Author)

  3. FGGE/SMMR-30 tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The Nimbus-7 FGGE/SMMR-30 tape which contains sea ice concentration data in 30 km resolution which are extracted and reformatted from Nimbus-7 SMMR PARM-30 tapes in accordance with the FGGE level II International Exchange Format Specification is outlined. There are three types of files on a FGGE/SMMR-30 tape. The first file on the tape is a test file. The second file on the tape is a tape header file. The remaining one or more files are data files. All files are terminated with a single end of file (EOP) tape mark. The last file is terminated with two EOF tape marks. All files are made up of one or more physical records. Each physical record contains 2960 bytes. Each data file contains all available values for a 6 hour synoptic time period.

  4. Distanced Data: Transcribing Other People's Research Tapes

    ERIC Educational Resources Information Center

    Tilley, Susan A.; Powick, Kelly D.

    2004-01-01

    In this article, we report on our qualitative study involving eight individuals hired to transcribe research tapes in university contexts. We consider issues of data analysis and data trustworthiness and the implications for both when transcription is assigned to someone other than the researcher. We explore the challenges transcribers faced…

  5. Red Tape: Its Origins, Uses, and Abuses.

    ERIC Educational Resources Information Center

    Kaufman, Herbert

    Red tape, particularly with reference to administration in the federal government, is described, and suggestions that have been proposed for improvement are explored. Among the frustrations that are met in dealing with government are duplicative and contradictory requirements of different agencies, restrictions imposed for announced ends that are…

  6. Tape Recording and the End Product.

    ERIC Educational Resources Information Center

    England, A. W.

    1970-01-01

    Intended to provide intense and immediate classroom experiences, tape recording projects of students can take several different forms: (1) unscripted plays and improvised situations (e.g., such "biographies" as "The Life of Charlie MacHerckumdingle: An Awkward Cuss"); (2) plays based on stories or poems (e.g., dramatizations of episodes from "The…

  7. Artificial Intelligence Controls Tape-Recording Sequence

    NASA Technical Reports Server (NTRS)

    Schwuttke, Ursula M.; Otamura, Roy M.; Zottarelli, Lawrence J.

    1989-01-01

    Developmental expert-system computer program intended to schedule recording of large amounts of data on limited amount of magnetic tape. Schedules recording using two sets of rules. First set incorporates knowledge of locations for recording of new data. Second set incorporates knowledge about issuing commands to recorder. Designed primarily for use on Voyager Spacecraft, also applicable to planning and sequencing in industry.

  8. "Space slitter" for film or tape

    NASA Technical Reports Server (NTRS)

    Johnson, W. H.

    1978-01-01

    Device cuts film or tape into strips by guiding film in channel under cutting blades. Device is operated by lifting pressure bar to insert blades into film. Film is then pulled through blades. Cutter has potential uses in advertising, commercial art, and publishing fields.

  9. Digital Audio Tape: Yet Another Archival Media?

    ERIC Educational Resources Information Center

    Vanker, Anthony D.

    1989-01-01

    Provides an introduction to the technical aspects of digital audiotape and compares it to other computer storage devices such as optical data disks and magnetic tape cartridges in terms of capacity, transfer rate, and cost. The current development of digital audiotape standards is also discussed. (five references) (CLB)

  10. Heat reflecting tape for thermoelectric converter

    DOEpatents

    Purdy, David L.

    1977-01-01

    Threads are interlaced with thermoelectric wires to provide a woven cloth in tape form, there being an intermediate layer of heat radiation reflecting material (e.g., aluminum foil) insulated electrically from said wires, which are of opposite thermoelectric polarity and connected as a plurality of thermocouples.

  11. Idea Bank: Duct Tape Note Twister

    ERIC Educational Resources Information Center

    McHenry, Molly

    2008-01-01

    In this article, the author relates how she observed a middle school math teacher deliver a miserable class. She realized that she did the same thing to her music students. To engage her students, she developed "Note Twister," a music reading game using duct tape to form musical notes and the basic premise behind the game,…

  12. Directory of Federal Agency Education Data Tapes.

    ERIC Educational Resources Information Center

    Feller, Barbara A.

    This directory is the initial result of a Congressional mandate to the National Center for Education Statistics (NCES) to improve coordination among Federal agencies concerned with the collection and use of education data. It identifies and describes education data bases, predominantly quantitiative, available on computer tape from Federal…

  13. Immediate Effects of Lumbopelvic Manipulation and Lateral Gluteal Kinesio Taping on Unilateral Patellofemoral Pain Syndrome

    PubMed Central

    Miller, Joseph; Westrick, Richard; Diebal, Angela; Marks, Christopher; Gerber, J. Parry

    2013-01-01

    Objectives: To determine the immediate effects of Kinesio taping directed to the hip and manipulation directed to the lumbopelvic region in individuals with unilateral patellofemoral pain syndrome (PFPS). Background: PFPS affects up to 25% of the general population. Despite the high prevalence, this condition is not clearly understood, as evidenced by the numerous proposed causes and recommended treatments. Notwithstanding, recent evidence suggests that treatments directed at the hip or spine may lead to beneficial results. Methods: A convenience sample of 18 participants (12 men and 6 women, 19.5 ± 1.15 years old) with unilateral PFPS was recruited. Participants were randomized by sex to 1 of 3 groups: Kinesio taping, manipulation, and control taping. The main outcome measures included the Y-balance test, squatting range of motion (ROM), and the Lower Extremity Functional Scale. Results: Compared with the lumbopelvic manipulation and control groups, those in the Kinesio taping group performed significantly better on the Y-balance test (F = 5.59, P = 0.02) and with squatting ROM (F = 3.93, P = 0.04). The Kinesio taping and lumbopelvic groups were also significantly better than the control (sham) group with double-leg squatting ROM performance 3 days later. Conclusion: Kinesio taping may facilitate gluteus medius activation and improve postural stability and a double-leg squat. Clinical Relevance: The improvement in affected limb reach and double-leg squatting ROM highlights the potential for Kinesio taping to improve gluteus medius activation. Lumbopelvic manipulation may also immediately improve rehabilitation programs for PFPS. PMID:24427391

  14. Effect of Kinesio Tape Application on Calf Pain and Ankle Range of Motion in Duathletes

    PubMed Central

    Merino-Marban, Rafael; Mayorga-Vega, Daniel; Fernandez-Rodriguez, Emilio

    The purpose of this study was to examine the effect of the kinesio tape immediately after its application and after a duathlon competition on calf pain and the ankle range of motion in duathletes. A sample of 28 duathletes (age 29.11 ± 10.35 years; body height 172.57 ± 6.17 cm; body mass 66.63 ± 9.01 kg; body mass index 22.29 ± 2.00 kg/m 2 ) were recruited from the competitors in a duathlon sprint. The Numerical Pain Rating Scale and ankle dorsiflexion range of motion measures were obtained at baseline, immediately after taping and 10 to 15 minutes after ending the duathlon competition. The kinesio tape was applied on the calf of duathletes 20 to 90 minutes before the competition, only on one of their legs (experimental leg) with the other leg acting as a control (control leg) in a randomized order. According to the between-group comparison, no differences were found immediately after the application of the kinesio tape and after the competition in the ankle range of motion and calf pain. However, a significant difference from baseline to immediately after taping was found in the ankle range of motion in the experimental leg. Applying the kinesio tape on the calf seems to immediately increase ankle dorsiflexion range of motion, but not after a duathlon competition. Applying the kinesio tape on the calf does not reduce muscle pain immediately or after a duathlon competition, but it appears to control an increase in pain. PMID:24146713

  15. Taping patients with clinical signs of subacromial impingement syndrome: the design of a randomized controlled trial

    PubMed Central

    2011-01-01

    Background Shoulder problems are a common complaint of the musculoskeletal system. Physical therapists treat these patients with different modalities such as exercise, massage, and shoulder taping. Although different techniques have been described, the effectiveness of taping has not yet been established. The aim of this study is to assess the effectiveness and cost-effectiveness of usual physical therapy care in combination with a particular tape technique for subacromial impingement syndrome of the shoulder compared to usual physical therapy care without this tape technique in a primary healthcare setting. Methods and design An economic evaluation alongside a randomized controlled trial will be conducted. A sample of 140 patients between 18 and 65 years of age with a diagnosis of subacromial impingement syndrome (SAIS) as assessed by physical therapists will be recruited. Eligible patients will be randomized to either the intervention group (usual care in combination with the particular tape technique) or the control group (usual care without this tape technique). In both groups, usual care will consist of individualized physical therapy care. The primary outcomes will be shoulder-specific function (the Simple Shoulder Test) and pain severity (11-point numerical rating scale). The economic evaluation will be performed using a societal perspective. All relevant costs will be registered using cost diaries. Utilities (Quality Adjusted Life Years) will be measured using the EuroQol. The data will be collected at baseline, and 4, 12, and 26 weeks follow-up. Discussion This pragmatic study will provide information about the effectiveness and cost-effectiveness of taping in patients presenting with clinical signs of SAIS. Trial registration Trial registration number: NTR2575 PMID:21849055

  16. Effect of kinesio tape application on calf pain and ankle range of motion in duathletes.

    PubMed

    Merino-Marban, Rafael; Mayorga-Vega, Daniel; Fernandez-Rodriguez, Emilio

    2013-01-01

    The purpose of this study was to examine the effect of the kinesio tape immediately after its application and after a duathlon competition on calf pain and the ankle range of motion in duathletes. A sample of 28 duathletes (age 29.11 ± 10.35 years; body height 172.57 ± 6.17 cm; body mass 66.63 ± 9.01 kg; body mass index 22.29 ± 2.00 kg/m(2)) were recruited from the competitors in a duathlon sprint. The Numerical Pain Rating Scale and ankle dorsiflexion range of motion measures were obtained at baseline, immediately after taping and 10 to 15 minutes after ending the duathlon competition. The kinesio tape was applied on the calf of duathletes 20 to 90 minutes before the competition, only on one of their legs (experimental leg) with the other leg acting as a control (control leg) in a randomized order. According to the between-group comparison, no differences were found immediately after the application of the kinesio tape and after the competition in the ankle range of motion and calf pain. However, a significant difference from baseline to immediately after taping was found in the ankle range of motion in the experimental leg. Applying the kinesio tape on the calf seems to immediately increase ankle dorsiflexion range of motion, but not after a duathlon competition. Applying the kinesio tape on the calf does not reduce muscle pain immediately or after a duathlon competition, but it appears to control an increase in pain.

  17. Editing of EIA coded, numerically controlled, machine tool tapes

    NASA Technical Reports Server (NTRS)

    Weiner, J. M.

    1975-01-01

    Editing of numerically controlled (N/C) machine tool tapes (8-level paper tape) using an interactive graphic display processor is described. A rapid technique required for correcting production errors in N/C tapes was developed using the interactive text editor on the IMLAC PDS-ID graphic display system and two special programs resident on disk. The correction technique and special programs for processing N/C tapes coded to EIA specifications are discussed.

  18. Adhesion and Cohesion

    PubMed Central

    von Fraunhofer, J. Anthony

    2012-01-01

    The phenomena of adhesion and cohesion are reviewed and discussed with particular reference to dentistry. This review considers the forces involved in cohesion and adhesion together with the mechanisms of adhesion and the underlying molecular processes involved in bonding of dissimilar materials. The forces involved in surface tension, surface wetting, chemical adhesion, dispersive adhesion, diffusive adhesion, and mechanical adhesion are reviewed in detail and examples relevant to adhesive dentistry and bonding are given. Substrate surface chemistry and its influence on adhesion, together with the properties of adhesive materials, are evaluated. The underlying mechanisms involved in adhesion failure are covered. The relevance of the adhesion zone and its importance with regard to adhesive dentistry and bonding to enamel and dentin is discussed. PMID:22505913

  19. Quantum dot (QD)-modified carbon tape electrodes for reproducible electrochemiluminescence (ECL) emission on a paper-based platform.

    PubMed

    Shi, Chuan-Guo; Shan, Xia; Pan, Zhong-Qin; Xu, Jing-Juan; Lu, Chang; Bao, Ning; Gu, Hai-Ying

    2012-03-20

    Stable and sensitive electrochemiluminescence (ECL) detection relies on successful immobilization of quantum dots (QDs) on working electrodes. Herein, we report a new technique to apply double-sided carbon adhesive tape as the working electrode to improve the stability and reproducibility of QD-based ECL emission. CdS QD-modified electrodes were prepared by dropping and drying CdS QD suspension on the carbon adhesive tape supported by indium tin oxide (ITO) glass. The ECL detection was performed with the prepared electrode on a paper-based platform. We tested our system using H(2)O(2) of various concentrations and demonstrated that consistent ECL emission could be obtained. We attribute stable and reproducible ECL emission to the robust attachment of CdS QDs on the carbon adhesive tape. The proposed method could be used to quantify the concentration of dopamine from 1 μM to 10 mM based on the quenching effect of dopamine on ECL emission of CdS QD system using H(2)O(2) as the coreactant. Our approach addressed the problem in the integration of stable QD-based ECL detection with portable paper-based analytical devices. The similar design offers great potential for low-cost electrochemical and ECL analytical instruments.

  20. Critical current degradation behaviour of GdBCO CC tapes in pure torsion and combined tension-torsion modes

    NASA Astrophysics Data System (ADS)

    Gorospe, Alking; Bautista, Zhierwinjay; Shin, Hyung-Seop

    2016-10-01

    Coated conductor (CC) tapes utilized in high-current-density superconducting cables are commonly subjected to different loading modes, primarily torsion and tension especially in the case of twisted stacked-tape cable. Torsion load can occur due to twisting along the length or when winding the CC tapes around a former, while tension load can occur due to pre-tension when coiled and as a hoop stress when the coil is energized. In this study, electromechanical properties of single CC tapes under torsion load were investigated using a new test apparatus. The results could provide basic information for cable designers to fully characterize stacked cables. Copper-electroplated and brass-laminated CC tapes fabricated with different deposition techniques were subjected to pure torsion and combined tension-torsion loading. The critical current, I c degradation behaviours of CC tapes under torsional deformation were examined. Also, the effect of further external lamination on the I c degradation behaviour of the CC tapes under such loading conditions was investigated. In the case of the combined tension-torsion test, short samples were subjected to twist pitches of 200 mm and 100 mm. Critical parameters including reversible axial stress and strain in such twist pitch conditions were also investigated.

  1. Full tape thickness feature conductors for EMI structures

    DOEpatents

    Peterson, Kenneth A.; Knudson, Richard T.; Smith, Frank R.; Barner, Gregory

    2014-06-10

    Generally annular full tape thickness conductors are formed in single or multiple tape layers, and then stacked to produce an annular solid conductive wall for enclosing an electromagnetic isolation cavity. The conductors may be formed using punch and fill operations, or by flowing conductor-containing material onto the tape edge surfaces that define the interior sidewalls of the cavity.

  2. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical magnetic tape recorder. 870.2800 Section 870.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record...

  3. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical magnetic tape recorder. 870.2800 Section 870.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record...

  4. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical magnetic tape recorder. 870.2800 Section 870.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record...

  5. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical magnetic tape recorder. 870.2800 Section 870.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record...

  6. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape...

  7. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical magnetic tape recorder. 870.2800 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2800 Medical magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record...

  8. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape...

  9. Tester automatically checks paper tape punch and reader after maintenance

    NASA Technical Reports Server (NTRS)

    Mazer, L.; Mc Murchy, D. D.

    1967-01-01

    Device automatically bench tests paper tape punches and readers in a simulated operating environment following routine maintenance. The reader and punch operate back-to-back and the paper tape output feeds the reader. The tape leader is prepunched with an arbitrary pattern that is continuously reproduced during the check.

  10. Dialects for the Stage: A Manual and Two Casette Tapes.

    ERIC Educational Resources Information Center

    Machlin, Evangeline

    This document contains a manual and two cassette tapes designed to help actors and actresses learn to speak various dialects. The tapes and the manual are arranged for the play-it-and-say-it method of dialect acquisition. The first three parts discuss the tapes and the manual in general, the dialect texts and dialect data, and the steps involved…

  11. A compact and bendable, hook-and-loop tape-based membraneless device for energy conversion

    NASA Astrophysics Data System (ADS)

    Ortiz-Ortega, E.; Gurrola, M. P.; Arjona, N.; Ledesma-García, J.; Arriaga, L. G.

    2016-12-01

    The new concept of a hook-and-loop tape-based membraneless device constructed on adhesive polyester film, which is fabricated using non-sophisticated and inexpensive fabrication techniques at room temperature, is presented. This concept overcomes the concerns about the reliability, versatility, weight, cost, lifetime and high performance of microfluidic fuel cell devices to satisfy the needs of portable energy applications. Current densities from 150 to 600 mA cm-2 and power densities from 40 to 132 mW cm-2 were achieved by varying the formic acid concentration, flow rates and by using air and dissolved oxygen as an oxidant.

  12. Electromagnetic properties of Bi-2223/Ag concentric tapes

    SciTech Connect

    Majoros, M.; Polak, M.; Kvitkovic, J.; Suchon, D.; Martini, L.; Ottoboni, V.; Zannella, S.

    1996-07-01

    It is well established that near the silver interface highly textured Bi-2223 layers compared to the inner ceramic core may be obtained. Thus Bi-2223 multilayered concentric tapes with silver matrix are very promising in increasing transport critical current densities. In the present work the authors report on the electromagnetic characterization of short tapes having in their cross-section a very thin HTS flattened ring with Ag inside and outside of it. The samples were prepared by the powder in tube method and have self-field critical current densities J{sub c} of the order of 3 {times} 10{sup 4} A/cm{sup 2} at 77 K. Transport and SQUID magnetization measurements revealed weak link nature of the samples in low magnetic fields. Large transport J{sub c}(B) hysteresis was observed at 4.2 K and magnetic fields up to 20 T. Magnetic field profiles measurements with miniature Hall sensors are in qualitative accordance with model calculations supposing homogeneous current density distribution across the superconducting core.

  13. Effects of balance taping using kinesiology tape in a patient with moderate hallux valgus

    PubMed Central

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    Abstract Background: Hallux valgus, an increased angle of lateral deviation in the big toe, can cause pain and difficulties in balancing and walking. This study aimed to investigate the effects of balance taping using elastic therapeutic tape on moderate hallux valgus. Methods: When she walked with shoes, she complained of pain over the medial eminence of the hallux metatarsophalangeal (MTP) joint. Balance taping using kinesiology tape was applied for 3 months (average, 16hours/d) to both big toes of a 26-year-old woman with moderate hallux valgus. Results: On the right side, the hallux valgus angle (HVA) decreased from 21° to 14° and the intermetatarsal angle (IMA) decreased from 15° to 14.5°. On the left side, the HVA decreased from 22° to 11° and the IMA decreased from 15° to 12°. Furthermore, the patient was able to walk long distances in shoes without pain in the medial eminence of the hallux metatarsophalangeal joint. Conclusion: This study suggested that repeated balance taping with kinesiology tape could be used as a complementary treatment method for moderate hallux valgus. PMID:27861365

  14. Effects of Tape and Exercise on Dynamic Ankle Inversion

    PubMed Central

    Ricard, Mark D.; Sherwood, Stephen M.; Schulthies, Shane S.; Knight, Kenneth L.

    2000-01-01

    Objective: To compare the effects of tape, with and without prewrap, on dynamic ankle inversion before and after exercise. Design and Setting: Doubly multivariate analyses of variance were used to compare the taping and exercise conditions. Subjects were randomly assigned to a fixed treatment order as determined by a balanced latin square. The independent variables were tape application (no tape, tape with prewrap, tape to skin) and exercise (before and after). The dependent variables were average inversion velocity, total inversion, maximum inversion velocity, and time to maximum inversion. Subjects: Thirty college-age male and female students (17 males, 13 females; mean age = 24.9 ± 4.3 years, range, 19 to 39 years) were tested. Subjects were excluded from the study if they exhibited a painful gait or painful range of motion or had a past history of ankle surgery or an ankle sprain within the past 4 weeks. Measurements: We collected data using electronic goniometers while subjects balanced on the right leg on an inversion platform tilted about the medial-lateral axis to produce 15° of plantar flexion. Sudden ankle inversion was induced by pulling the inversion platform support, allowing the platform support base to rotate 37°. Ten satisfactory trials were recorded on the inversion platform before and after a prescribed exercise bout. We calculated total inversion, time to maximum inversion, average inversion velocity, and maximum inversion velocity after sudden inversion. Results: We found no significant differences between taping to the skin and taping over prewrap for any of the variables measured. There were significant differences between both taping conditions and no-tape postexercise for average inversion velocity, maximum inversion, maximum inversion velocity, and time to maximum inversion. The total inversion mean for no-tape postexercise was 38.8° ± 6.3°, whereas the means for tape and skin and for tape and prewrap were 28.3° ± 4.6° and 29.1°

  15. Anisotropic thermal transport in double-pancake coil wound with DI-BSCCO® tape

    NASA Astrophysics Data System (ADS)

    Naito, T.; Fujishiro, H.; Yamada, Y.

    2010-11-01

    We have measured the temperature dependence of the thermal resistances Rr(T) and Rz(T) of the parallelepiped samples cut from a double-pancake coil along the radial (r) and the thickness (z) directions, respectively. The double-pancake coil was wound with DI-BSCCO® tape fabricated by Sumitomo Electric Industries, Ltd. DI-BSCCO is a (Bi, Pb)2Sr2Ca2Cu3O10+x tape sheathed with silver. Both Rr(T) and Rz(T) increase monotonically with decreasing temperature. We analyze the thermal transport in the coil by use of the parallel and series heat current circuit of DI-BSCCO tapes and insulators.

  16. Anomalous anisotropy of critical currents in (Sr, K)Fe2As2 tapes

    NASA Astrophysics Data System (ADS)

    Awaji, Satoshi; Nakazawa, Yushiro; Oguro, Hidetoshi; Tsuchiya, Yuji; Watanabe, Kazuo; Shimada, Yusuke; Lin, He; Yao, Chao; Zhang, Xianping; Ma, Yanwei

    2017-03-01

    We measured critical currents and irreversibility fields of Ag-sheath (Sr, K)Fe2As2 tapes at various temperatures, magnetic fields and magnetic field directions. The sample tapes were made by a powder-in-tube with a hot-press process in the final heat treatments. The inverse anisotropy in J c in comparison with the effective mass anisotropy can be found in the hot-pressed (Sr, K)Fe2As2 tapes. We found that the broad c-axis peak in angular dependence of J c appears in a low field region and it decreases with increasing field and temperature. In addition, the crossover of J c anisotropy appears around 10 T at 4.2 K and the crossover field decreases with increasing temperature. It is considered that these unusual anisotropic J c behaviors may be originated by the strong random pinning center which is larger than the coherence length,

  17. AAMFT Master Series Tapes: An Analysis of the Inclusion of Feminist Principles into Family Therapy Practice.

    ERIC Educational Resources Information Center

    Haddock, Shelley A.; MacPhee, David; Zimmerman, Toni Schindler

    2001-01-01

    Content analysis of 23 American Association for Marriage and Family Therapy Master Series tapes was used to determine how well feminist behaviors have been incorporated into ideal family therapy practice. Feminist behaviors were infrequent, being evident in fewer than 3% of time blocks in event sampling and 10 of 39 feminist behaviors of the…

  18. Census of Population and Housing, 1980: Summary Tape File 3F. Technical Documentation.

    ERIC Educational Resources Information Center

    Bureau of the Census (DOC), Washington, DC. Data User Services Div.

    This report provides technical documentation associated with a 1980 Census of Population and Housing Summary Tape File (STF) 3F--which contains responses to the extended questionnaire summarized in STF 3, aggregated by school district. The file contains sample data inflated to represent the total population, 100% counts, and unweighted sample…

  19. Influence of composition on the adhesive strength and initial viscosity of denture adhesives.

    PubMed

    Han, Jian-min; Hong, Guang; Hayashida, Kentaro; Maeda, Takeshi; Murata, Hiroshi; Sasaki, Keiichi

    2014-01-01

    To investigate the effect of composition on the initial viscosity and adhesive strength between denture adhesives and the denture base. Two types of water-soluble polymers (methoxy ethylene maleic anhydride copolymer [PVM-MA] and sodium carboxymethyl cellulose [CMC]) were used. Samples were divided into three groups. Group 1 contained only PVM-MA; Group 2 contained only CMC; and Group 3 contained PVM-MA and CMC. The initial viscosity and adhesive strength were measured. For Group 1, the initial viscosity increased significantly as PVM-MA content increased. The adhesive strength of Group 1 lasted longer than Group 2. The adhesive strength of Group 3 varied greatly. The ratio of CMC and PVM-MA has a significant effect on the initial viscosity and adhesive strength of denture adhesives. Our results suggest that it is possible to improve the durability of a denture adhesive by combining different water-soluble polymers.

  20. Effect of starting materials on the superconducting properties of SmFeAsO1-xFx tapes

    NASA Astrophysics Data System (ADS)

    Wang, Chunlei; Yao, Chao; Zhang, Xianping; Gao, Zhaoshun; Wang, Dongliang; Wang, Chengduo; Lin, He; Ma, Yanwei; Awaji, Satoshi; Watanabe, Kazuo

    2012-03-01

    SmFeAsO1-xFx tapes were prepared using three kinds of starting materials. This showed that the starting materials have an obvious effect on the impurity phases in the final superconducting tapes. Compared with the other samples, the samples fabricated with SmAs, FeO, Fe2As, and SmF3 have the smallest arsenide impurity phases and voids. As a result, these samples possess much denser structures and better grain connectivities. Moreover, among the three kinds of sample fabricated in this work, this kind of sample has the highest zero resistivity temperature, ˜40 K, and the largest critical current density, ˜4600 A cm-2, in self-field at 4.2 K. This is the highest Jc value reported so far for SmFeAsO1-xFx wires and tapes.

  1. Energy Data Base: output magnetic tape description

    SciTech Connect

    Busse, A.E.

    1982-06-01

    This document describes a format for disseminating bibliographic citations, abstracts and subject content indicators for energy information on computer readable magnetic tape issued after July 1976. The magnetic tapes contain information incorporated into the DOE data base. This base is used by TIC to generate multiple publications and to support information retrieval activities. Information, or data, pertinent to one bibliographic reference will be called an entry. The entries are logically composed of data elements (such as title, authors, etc.). This format supersedes a previous version, used since 1974, as described in Report TID-4581-R4. The format has been revised to permit incorporation of DOE/TIC bibliographic data encompassing the broader scope of information related to the development or use of energy resources.

  2. Deployable Hexapod Using Tape-Springs

    DTIC Science & Technology

    2005-07-13

    main advantages of this concept compared to classical hyper-stable telescope structures are: - a reduced volume during launch allowing large systems...The main advantages of a deployable and active telescope structure compared to classical hyperstable telescope structures are a reduced volume...developed and manufactured by IWF TÜ Braunschweig who already applied them to motorised applications. The steel tape-spring can be rolled in the coiling

  3. Software Computes Tape-Casting Parameters

    NASA Technical Reports Server (NTRS)

    deGroh, Henry C., III

    2003-01-01

    Tcast2 is a FORTRAN computer program that accelerates the setup of a process in which a slurry containing metal particles and a polymeric binder is cast, to a thickness regulated by a doctor blade, onto fibers wound on a rotating drum to make a green precursor of a metal-matrix/fiber composite tape. Before Tcast2, setup parameters were determined by trial and error in time-consuming multiple iterations of the process. In Tcast2, the fiber architecture in the final composite is expressed in terms of the lateral distance between fibers and the thickness-wise distance between fibers in adjacent plies. The lateral distance is controlled via the manner of winding. The interply spacing is controlled via the characteristics of the slurry and the doctor-blade height. When a new combination of fibers and slurry is first cast and dried to a green tape, the shrinkage from the wet to the green condition and a few other key parameters of the green tape are measured. These parameters are provided as input to Tcast2, which uses them to compute the doctor-blade height and fiber spacings needed to obtain the desired fiber architecture and fiber volume fraction in the final composite.

  4. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 3 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 6 and 7. The activities from other flight days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). Flight day 6 features a very complicated EVA (extravehicular activity) to service the HST (Hubble Space Telescope). Astronauts Grunsfeld and Linnehan replace the HST's power control unit, disconnecting and reconnecting 36 tiny connectors. The procedure includes the HST's first ever power down. The cleanup of spilled water from the coollant system in Grunsfeld's suit is shown. The pistol grip tool, and two other space tools are also shown. On flight day 7, Newman and Massimino conduct an EVA. They replace the HST's FOC (Faint Object Camera) with the ACS (Advanced Camera for Surveys). The video ends with crew members playing in the shuttle's cabin with a model of the HST.

  5. Multifunctional Carbon Fibre Tapes for Automotive Composites

    NASA Astrophysics Data System (ADS)

    Koncherry, V.; Potluri, P.; Fernando, A.

    2017-04-01

    Cabon fibre composites are used where mechanical performance such as strength, stiffness and impact properties at low density is a critical parameter for engineering applications. Carbon fibre flat tape is one material which is traditionally used to manufacture three-dimensional composites in this area. Modifying the carbon fibre tape to incorporate other functions such as stealth, electromagnetic interference, shielding, de-icing, self-repair, energy storage, allows us to create multi-functional carbon fibre tape. Researchers have been developing such material and the technology for their manufacture in order to produce multifunctional carbon fibre based components more economically and efficiently. This paper presents the manufacturing process of a metallised carbon fibre material for a chopped fibre preforming process that uses electromagnets for preforming instead of traditional suction airflow fibre deposition. In addition, the paper further presents mechanical and magneto-static modelling that is carried out to investigate the bending properties of the material produced and its suitability for creating 3D preforms.

  6. Multifunctional Carbon Fibre Tapes for Automotive Composites

    NASA Astrophysics Data System (ADS)

    Koncherry, V.; Potluri, P.; Fernando, A.

    2016-11-01

    Cabon fibre composites are used where mechanical performance such as strength, stiffness and impact properties at low density is a critical parameter for engineering applications. Carbon fibre flat tape is one material which is traditionally used to manufacture three-dimensional composites in this area. Modifying the carbon fibre tape to incorporate other functions such as stealth, electromagnetic interference, shielding, de-icing, self-repair, energy storage, allows us to create multi-functional carbon fibre tape. Researchers have been developing such material and the technology for their manufacture in order to produce multifunctional carbon fibre based components more economically and efficiently. This paper presents the manufacturing process of a metallised carbon fibre material for a chopped fibre preforming process that uses electromagnets for preforming instead of traditional suction airflow fibre deposition. In addition, the paper further presents mechanical and magneto-static modelling that is carried out to investigate the bending properties of the material produced and its suitability for creating 3D preforms.

  7. Current Distribution in Wide YBCO Tapes

    NASA Astrophysics Data System (ADS)

    Carrera, M.; Granados, X.; Amorós, J.; Puig, T.; Obradors, X.

    The need of a better mechanical behaviour and the stabilization of coated conductors for applications, as Magnets, cables or Fault Current Limiters, has motivated the lamination of tapes with stainless steel or copper alloys, increasing so the elastic modulus of the conductors and their mechanical performance. Some of the stainless steels used are magnetic, thus introducing some perturbations of the current flow when energizing the conductor. In order to detect these possible perturbations, the magnetic self field in the surface of the tape has been explored by Hall mapping technique at several current loads in a monotonically driven cyclic sequence. By increasing current steps when loading up, crossing the critical field threshold, and decreasing down to remanent state. Deviation from the expected magnetic map has been observed. In this work, we will report on the resulting measurements, and the current flow is calculated by solving the inverse problem for a 12 mm wide stainless steel reinforced Coated Conductor tape. We discuss on the likely origin of the observed perturbations.

  8. Kinesio taping in treatment and prevention of sports injuries: a meta-analysis of the evidence for its effectiveness.

    PubMed

    Williams, Sean; Whatman, Chris; Hume, Patria A; Sheerin, Kelly

    2012-02-01

    Kinesio tape (KT) is an elastic therapeutic tape used for treating sports injuries and a variety of other disorders. Chiropractor, Dr Kenso Kase, developed KT taping techniques in the 1970s. It is claimed that KT supports injured muscles and joints and helps relieve pain by lifting the skin and allowing improved blood and lymph flow. The profile of KT rose after the tape was donated to 58 countries for use during the 2008 Olympic Games, and was seen on high-profile athletes. Practitioners are asking whether they should use KT over other elastic adhesive tapes. The aim of this review was to evaluate, using meta-analysis, the effectiveness of KT in the treatment and prevention of sports injuries. Electronic databases including SPORTDiscus, Scopus, MEDLINE, ScienceDirect and sports medicine websites were searched using keywords 'kinesio taping/tape'. From 97 articles, ten met the inclusion criteria (article reported data for effect of KT on a musculoskeletal outcome and had a control group) and were retained for meta-analyses. Magnitude-based inferences were used to assess clinical worth of positive outcomes reported in studies. Only two studies investigated sports-related injuries (shoulder impingement), and just one of these involved injured athletes. Studies attending to musculoskeletal outcomes in healthy participants were included on the basis that these outcomes may have implications for the prevention of sporting injuries. The efficacy of KT in pain relief was trivial given there were no clinically important results. There were inconsistent range-of-motion outcome results, with at least small beneficial results seen in two studies, but trivial results in two other studies across numerous joint measurements. There was a likely beneficial effect for proprioception regarding grip force sense error, but no positive outcome for ankle proprioception. Seven outcomes relating to strength were beneficial, although there were numerous trivial findings for quadriceps and

  9. The spectroscopic detection of exogenous material in fingerprints after development with powders and recovery with adhesive lifters.

    PubMed

    West, Matthew J; Went, Michael J

    2008-01-15

    The application of powders to fingerprints has long been established as an effective and reliable method for developing latent fingerprints. The powders adhere to the ridge pattern of the fingerprint only, thus allowing the image to be visualised. Fingerprints developed in situ at a crime scene routinely undergo lifting with specialist tapes to facilitate subsequent laboratory analysis. As with all recovered evidence these samples would be stored in evidence bags to allow secure transit from the scene to the laboratory and also to preserve the chain of evidence. In this paper, the application of Raman spectroscopy for the analysis of exogenous material in latent fingerprints is reported for contaminated fingerprints that had been treated with powders and also subsequently lifted with adhesive tapes. A selection of over the counter (OTC) analgesics were used as samples for the analysis and contaminated fingerprints were deposited on clean glass slides. The application of aluminium or iron based powders to contaminated fingerprints did not interfere with the Raman spectra obtained for the contaminants. In most cases background fluorescence attributed to the sebaceous content of the latent fingerprint was reduced by the application of the powder thus reducing spectral interference. Contaminated fingerprints developed with powders and then lifted with lifting tapes were also examined. The combination of these two techniques did not interfere with the successful analysis of exogenous contaminants by Raman spectroscopy. The lifting process was repeated using hinge lifters. As the hinge lifters exhibited strong Raman bands the spectroscopic analysis was more complex and an increase in the number of exposures to the detector allowed for improved clarification. Raman spectra of developed and lifted fingerprints recorded through evidence bags were obtained and it was found that the detection process was not compromised in any way. Although the application of powders did not

  10. Anisotropic shrinkage characteristics of tape cast alumina

    NASA Astrophysics Data System (ADS)

    Patwardhan, Jaideep Suresh

    Dimensional control during sintering is a major issue in ceramics processing to avoid high post-sintering costs associated with machining of the fired ceramic part to desired tolerances and dimensions. Ceramic forming processes such as tape casting, injection molding, and extrusion involve shear of anisotropic particles resulting in preferential alignment of the particles in the green body. This preferential alignment causes directionality in mechanical, electrical, optical, and magnetic properties and most importantly warpage or distortion during sintering. A large effort has been devoted to synthesizing ceramic green bodies with minimal density gradients and uniform packing and modeling the sintering behavior evolution but little effort has been devoted to characterizing orientation of particles and the effect of preferential alignment on sintering shrinkage anisotropy. A systematic study was initiated to study the effect of processing variables such as shear rate, solids loading, temperature, and binder content on aqueous tape cast alumina. Three different alumina systems: A16-SG, Baikowski RC-UFX DBM and RC-LS DBM were investigated. Aqueous tapes of high solids loading alumina (56 vol. %) were tape cast at various speeds and thicknesses and assuming plane Couette flow a shear rate regime of 21--270 s-1 was investigated. Higher shear rates and high solids loading resulted in higher in-plane anisotropy whereas the anisotropy in the thickness direction was higher for low solids loading systems. The anisotropy was found to be fairly constant above a certain critical shear rate (˜100 s-1) irrespective of the temperature and the solids loading and this correlated with the viscosity-shear rate relationship of the cast slips. The higher shrinkage anisotropy in the thickness direction for the low solids loading systems (35 and 45 vol. %) was attributed to the higher amount of organics in the slip required to sustain the suitable viscosity for tape casting and

  11. Urethane/Silicone Adhesives for Bonding Flexing Metal Parts

    NASA Technical Reports Server (NTRS)

    Edwards, Paul D.

    2004-01-01

    Adhesives that are blends of commercially available urethane and silicone adhesives have been found to be useful for bonding metal parts that flex somewhat during use. These urethane/silicone adhesives are formulated for the specific metal parts to be bonded. The bonds formed by these adhesives have peel and shear strengths greater than those of bonds formed by double-sided tapes and by other adhesives, including epoxies and neat silicones. In addition, unlike the bonds formed by epoxies, the bonds formed by these adhesives retain flexibility. In the initial application for which the urethane/silicone adhesives were devised, there was a need to bond spring rings, which provide longitudinal rigidity for inflatable satellite booms, with the blades that provide the booms axial strength. The problem was to make the bonds withstand the stresses, associated with differences in curvature between the bonded parts, that arose when the booms were deflated and the springs were compressed. In experiments using single adhesives (that is, not the urethane/ silicone blends), the bonds were broken and, in each experiment, it was found that the adhesive bonded well with either the ring or with the blade, but not both. After numerous experiments, the adhesive that bonded best with the rings and the adhesive that bonded best with the blades were identified. These adhesives were then blended and, as expected, the blend bonded well with both the rings and the blades. The two adhesives are Kalex (or equivalent) high-shear-strength urethane and Dow Corning 732 (or equivalent) silicone. The nominal mixture ratio is 5 volume parts of the urethane per 1 volume part of the silicone. Increasing the proportion of silicone makes the bond weaker but more flexible, and decreasing the proportion of silicone makes the bond stronger but more brittle. The urethane/silicone blend must be prepared and used quickly because of the limited working time of the urethane: The precursor of the urethane

  12. Thermoelectric instability induced by single pulses and alternating currents in second-generation superconducting tapes

    NASA Astrophysics Data System (ADS)

    Degtyarenko, P. N.; Dul'kin, I. N.; Fisher, L. M.; Kalinov, A. V.; Voloshin, I. F.; Yampol'skii, V. A.

    2011-02-01

    We have studied current flow instabilities in a second-generation superconducting tapes and the transition of the tapes into the resistive state. Contrary to the usual quasisteady instability regimes, here we consider the adiabatic case in which the sample is heated rapidly. Two kinds of measurements of the current-voltage characteristics (CVC) have been made, specifically, with excitation of the tape by a single sinusoidal current pulse I (t)=I0sin(ωt) at different amplitudes I0 and by a continuous ac current. The main results were obtained for current amplitudes I0 exceeding the critical current Ic. We find that the dynamic CVC are essentially reversible for low amplitudes, whereas they become irreversible and acquire an N-shape for higher current amplitudes. The dynamic CVC change radically if the dissipated energy attains a threshold value Wth roughly equal to 5mJ/cm for our tapes. When this energy is reached, the tape undergoes a transition to the resistive state owing to formation of normal domains. The development of the instability with steady ac currents was studied at relatively small amplitudes such that the energy dissipated per half cycle is much lower than Wth. Even in this case, a tape undergoes a transition to the resistive state because of energy accumulation (heat pumping). With this pumping, the transition takes place after a definite number of ac cycles, when the total accumulated energy reaches the same threshold value Wth. The specific features of the dynamic CVC are interpreted qualitatively, with the appearance of resistive domains taken into account. Estimates based on the CVC agree well with our experimental data. These results can be useful in the design of superconducting fault current limiters.

  13. Plasma polymerization for cell adhesive/anti-adhesive implant coating

    NASA Astrophysics Data System (ADS)

    Meichsner, Juergen; Testrich, Holger; Rebl, Henrike; Nebe, Barbara

    2015-09-01

    Plasma polymerization of ethylenediamine (C2H8N2, EDA) and perfluoropropane (C3F8, PFP) with admixture of argon and hydrogen, respectively, was studied using an asymmetric 13.56 MHz CCP. The analysis of the plasma chemical gas phase processes for stable molecules revealed consecutive reactions: C2H8N2 consumption, intermediate product NH3, and main final product HCN. In C3F8- H2 plasma the precursor molecule C3F8 and molecular hydrogen are consumed and HF as well as CF4 and C2F6 are found as main gaseous reaction products. The deposited plasma polymer films on the powered electrode are strongly cross-linked due to ion bombardment. The stable plasma polymerized films from EDA are characterized by high content of nitrogen with N/C ratio of about 0.35. The plasma polymerized fluorocarbon film exhibit a reduced F/C ratio of about 1.2. Adhesion tests with human osteoblast cell line MG-63 on coated Ti6Al4V samples (polished) compared with uncoated reference sample yielded both, the enhanced cell adhesion for plasma polymerized EDA and significantly reduced cell adhesion for fluorocarbon coating, respectively. Aging of the plasma polymerized EDA film, in particular due to the reactions with oxygen from air, showed no significant change in the cell adhesion. The fluorocarbon coating with low cell adhesion is of interest for temporary implants. Funded by the Campus PlasmaMed.

  14. Chemical Analyses of Silicon Aerogel Samples

    SciTech Connect

    van der Werf, I.; Palmisano, F.; De Leo, Raffaele; Marrone, Stefano

    2008-04-01

    After five years of operating, two Aerogel counters: A1 and A2, taking data in Hall A at Jefferson Lab, suffered a loss of performance. In this note possible causes of degradation have been studied. In particular, various chemical and physical analyses have been carried out on several Aerogel tiles and on adhesive tape in order to reveal the presence of contaminants.

  15. Effects of Kinesio Taping versus McConnell Taping for Patellofemoral Pain Syndrome: A Systematic Review and Meta-Analysis

    PubMed Central

    Chang, Wen-Dien; Chen, Fu-Chen; Lee, Chia-Lun; Lin, Hung-Yu; Lai, Ping-Tung

    2015-01-01

    Objectives. To conduct a systematic review comparing the effects of Kinesio taping with McConnell taping as a method of conservative management of patients with patellofemoral pain syndrome (PFPS). Methods. MEDLINE, PUBMED, EMBASE, AMED, and the Cochrane Central Register of Control Trials electronic databases were searched through July 2014. Controlled studies evaluating the effects of Kinesio or McConnell taping in PFPS patients were retrieved. Results. Ninety-one articles were selected from the articles that were retrieved from the databases, and 11 articles were included in the analysis. The methods, evaluations, and results of the articles were collected, and the outcomes of patellar tapings were analyzed. Kinesio taping can reduce pain and increase the muscular flexibility of PFPS patients, and McConnell taping also had effect in pain relief and patellar alignment. Meta-analysis showed small effect in pain reduction and motor function improvement and moderate effect in muscle activity change among PFPS patients using Kinesio taping. Conclusions. Kinesio taping technique used for muscles can relieve pain but cannot change patellar alignment, unlike McConnell taping. Both patellar tapings are used differently for PFPS patients and substantially improve muscle activity, motor function, and quality of life. PMID:26185517

  16. Thermal Characterization of Adhesive

    NASA Technical Reports Server (NTRS)

    Spomer, Ken A.

    1999-01-01

    The current Space Shuttle Reusable Solid Rocket Motor (RSRM) nozzle adhesive bond system is being replaced due to obsolescence. Down-selection and performance testing of the structural adhesives resulted in the selection of two candidate replacement adhesives, Resin Technology Group's Tiga 321 and 3M's EC2615XLW. This paper describes rocket motor testing of these two adhesives. Four forty-pound charge motors were fabricated in configurations that would allow side by side comparison testing of the candidate replacement adhesives and the current RSRM adhesives. The motors provided an environment where the thermal performance of adhesives in flame surface bondlines was compared. Results of the FPC testing show that: 1) The phenolic char depths on radial bond lines is approximately the same and vary depending on the position in the blast tube regardless of which adhesive was used; 2) The adhesive char depth of the candidate replacement adhesives is less than the char depth of the current adhesives; 3) The heat-affected depth of the candidate replacement adhesives is less than the heat-affected depth of the current adhesives; and 4) The ablation rates for both replacement adhesives are slower than that of the current adhesives.

  17. Effects of two different knee tape procedures on lower-limb kinematics and kinetics in recreational runners.

    PubMed

    Howe, A; Campbell, A; Ng, L; Hall, T; Hopper, D

    2015-08-01

    The purpose of this study was to compare the effects of Mulligan's tape (MT) and kinesio tape (KT) with no tape (NT) on hip and knee kinematics and kinetics during running. Twenty-nine female recreational runners performed a series of 'run-throughs' along a 10-m runway under the three taping conditions. Two force plates and a 14-camera Vicon motion analysis system (Oxford Metrics, Inc., Oxford, UK) captured kinematic and kinetic data for each dependent variable from ground contact to toe off. Comparisons of each dependent variable under three taping conditions were assessed through Statistical Package for the Social Sciences (SPSS; SPSS, Inc., Chicago, Illinois, USA; P-value < 0.01) using repeated measure analyses of variance. For each dependent variable with a P-value < 0.01, repeated measures with pairwise comparisons and Bonferroni adjustment were conducted to compare the three taping conditions. MT induced a significant reduction in anterior and posterior hip forces, knee flexion angular velocity, knee extensor moments, and hip flexion and extension moments compared with NT and KT (P = 0.001). There was no difference in hip or knee, kinematics or kinetics, between KT and NT (P = 1.000). MT appears to influence hip and knee biomechanics during running in an asymptomatic sample, whereas KT appeared to be biomechanically not different from NT.

  18. Selective laser densification of lithium aluminosilicate glass ceramic tapes

    NASA Astrophysics Data System (ADS)

    Zocca, Andrea; Colombo, Paolo; Günster, Jens; Mühler, Thomas; Heinrich, Jürgen G.

    2013-01-01

    Tapes, cast by blade deposition of a lithium aluminosilicate glass slurry, were sintered using a YAG-fiber laser, with the aim of finding suitable parameters for an additive manufacturing process based on layer-wise slurry deposition and selective laser densification. The influence of the laser parameters (output power and scan velocity) on the sintering was evaluated, by scanning electron microscopy and by X-ray diffraction, on the basis of the quality of the processed layer. Well densified samples could be obtained only in a small window of values for the output power and the scan velocity. The measurement of the width of a set of single scanned lines allowed also to estimate the minimum resolution of the system along the layer plane.

  19. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    SciTech Connect

    Goyal, Amit

    2013-07-09

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  20. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    SciTech Connect

    Goyal, Amit

    2012-07-24

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  1. Kinetics of the humid aging of magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Bertram, H. N.; Cuddihy, E. F.

    1982-01-01

    The kinetics of the hydrolysis of polyester urethane binders of magnetic recording tape is described. Kinetic data were generated from measurements of acetone-extractable hydrolyzed binder products versus time for various humidity-temperature environments. These data can be described by a linear, single product, reversible rate equation. This equation, coupled with measurements on the effect of hydrolysis on recorded tape performance, is used to predict proper environmental storage conditions for magnetic tape.

  2. GSFC specification electronic data processing magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Tinari, D. F.; Perry, J. L.

    1980-01-01

    The design requirements are given for magnetic oxide coated, electronic data processing tape, wound on reels. Magnetic recording tape types covered by this specification are intended for use on digital tape transports using the Non-Return-to-Zero-change-on-ones (NRZI) recording method for recording densities up to and including 800 characters per inch (cpi) and the Phase-Encoding (PE) recording method for a recording density of 1600 cpi.

  3. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 2 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 4 and 5. The activities from other flights days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139476), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). The primary activities during these days were EVAs (extravehicular activities) to replace two solar arrays on the HST (Hubble Space Telescope). Footage from flight day 4 records an EVA by Grunsfeld and Linnehan, including their exit from Columbia's payload bay airlock, their stowing of the old HST starboard rigid array on the rigid array carrier in Columbia's payload bay, their attachment of the new array on HST, the installation of a new starboard diode box, and the unfolding of the new array. The pistol grip space tool used to fasten the old array in its new location is shown in use. The video also includes several shots of the HST with Earth in the background. On flight day 5 Newman and Massimino conduct an EVA to change the port side array and diode box on HST. This EVA is very similar to the one on flight day 4, and is covered similarly in the video. A hand operated ratchet is shown in use. In addition to a repeat of the previous tasks, the astronauts change HST's reaction wheel assembly, and because they are ahead of schedule, install installation and lubricate an instrument door on the telescope. The Earth views include a view of Egypt and Israel, with the Nile River, Red Sea, and Mediterranean Sea.

  4. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 1 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 1 through 3. The activities from other flight days can be seen on 'STS 109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), 'STS 109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139471), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). The main activity recorded during flight day 1 is the liftoff of Columbia. Attention is given to suit-up, boarding, and pre-flight procedures. The pre-launch crew meal has no sound. The crew members often wave to the camera before liftoff. The jettisoning of the solid rocket boosters is shown, and the External Tank is seen as it falls to Earth, moving over African dunes in the background. There are liftoff replays, including one from inside the cockpit. The opening of the payload bay doors is seen from the rear of the shuttle's cockpit. The footage from flight day 2 shows the Flight Support System for bearthing the HST (Hubble Space Telescope). Crew preparations for the bearthing are shown. Flight day 3 shows the tracking of and approach to the HST by Columbia, including orbital maneuvers, the capture of the HST, and its lowering onto the Flight Support System. Many views of the HST are shown, including one which reveals an ocean and cloud background as the HST retracts a solar array.

  5. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 4 of 4, shows footage of crew activities from flight days 8 through 12 of STS-109. The crew included: Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, Richard Linnehan, James Newman, Michael Massimino, Mission Speicalists. The activities from other flights days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), and 'STS-109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139476). The primary activity on flight day 8 was an EVA (extravehicular activity) by Grunsfeld and Linnehan to install a cryocooler and radiator for the NICMOS (Near Infrared Camera and Multi-Object Spectrometer) on the HST (Hubble Space Telescope). Before returning to Columbia's airlock, the astronauts, with a cloudy background, hold onto the orbiter and offer their thoughts on the significance of their mission, the HST, and spaceflight. Footage from flight day 9 includes the grappling, unbearthing, and deployment of the HST from Columbia, and the crew coordinating and videotaping Columbia's departure. Flight day 10 was a relatively inactive day, and flight day 11 includes a checkout of Columbia's aerodynamic surfaces. Columbia landed on flight day 12, which is covered by footage of the crew members speaking during reentry, and their night landing, primarily shown through the orbiter's head-up display. The video includes numerous views of the HST, as well as views of the the Galapagos Islands, Madagascar, and Southern Africa with parts of the Atlantic, Indian, and Pacific Oceans, and part of the coast of Chile. The pistol grip space tool is shown in use, and the crew answers two messages from the public, including a message to Massimino from the Fire Department of New York.

  6. STS-111 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-08-01

    This video, Part 1 of 4, shows the activities of the STS-111 crew (Kenneth Cockrell, Commander; Paul Lockhart, Pilot; Franklin Chang-Diaz, Phillipe Perrin, Mission Specialists) during flight days 1 through 4. Also shown are the incoming Expedition 5 (Valeri Korzun, Commander; Peggy Whitson, NASA ISS Science Officer; Sergei Treschev, Flight Engineer) and outgoing Expedition 4 (Yuri Onufriyenko, Commander; Carl Walz, Daniel Bursch, Flight Engineers) crews of the ISS (International Space Station). The activities from other flight days can be seen on 'STS-111 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002139469), 'STS-111 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139468), and 'STS-111 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002139474). The primary activity of flight day 1 is the launch of Space Shuttle Endeavour. The crew is seen before the launch at a meal and suit-up, and some pre-flight procedures are shown. Perrin holds a sign with a personalized message. The astronauts communicate with Mission Control extensively after launch, and an inside view of the shuttle cabin is shown. The replays of the launch include close-ups of the nozzles at liftoff, and the fall of the solid rocket boosters and the external fuel tank. Flight day 2 shows footage of mainland Asia at night, and daytime views of the eastern United States and Lake Michigan. Flight day three shows the Endeavour orbiter approaching and docking with the ISS. After the night docking, the crews exchange greetings, and a view of the Nile river and Egypt at night is shown. On flight day 4, the MPLM (Multi-Purpose Logistics Module) Leonardo was temporarily transferred from Endeavour's payload bay to the ISS.

  7. Bond strength of adhesive resin cement with different adhesive systems

    PubMed Central

    Lorenzoni e Silva, Fabrizio; Pamato, Saulo; Kuga, Milton-Carlos; Só, Marcus-Vinicius-Reis

    2017-01-01

    Background To assess the immediate bond strength of a dual-cure adhesive resin cement to the hybridized dentin with different bonding systems. Material and Methods Fifty-six healthy human molars were randomly divided into 7 groups (n=8). After 3 longitudinal sections, the central cuts were included in PVC matrix and were submitted to dentin hybridization according to the groups: G1 - etch & rinse system with 3-step (Apder™ Scotchbond™ Multi-Purpose, 3M ESPE), G2 - etch & rinse system with 3-step (Optibond™ FL, Kerr), G3 - etch & rinse system with 3-step (All-Bond 3®, Bisco), G4 - etch & rinse simplified system (Adper™ Single Bond 2, 3M ESPE), G5 - self-etching system with one step (Bond Force, Tokuyama), G6 - universal system in moist dentin (Single Bond Universal, 3M ESPE), G7 - universal system in dry dentin (Single Bond Universal, 3M ESPE). Then all groups received the cementing of a self-adhesive resin cement cylinder (Duo-link, Bisco) made from a polypropylene matrix. In the evaluation of bond strength, the samples were subjected to the microshear test and evaluated according to the fracture pattern by optical microscopy. Results The Kruskal-Wallis test suggests a statistically significant difference between groups (p=0,039), and Tukey for multiple comparisons, indicating a statistically significant difference between G3 and G4 (p<0.05). It was verified high prevalence of adhesive failures, followed by mixed failure and cohesive in dentin. Conclusions The technique and the system used to dentin hybridization are able to affect the immediate bond strength of resin cement dual adhesive. Key words:Adhesion, adhesive resin cement, adhesive systems, microshear. PMID:28149471

  8. Superior high-field current density in slightly Mg-deficient MgB2 tapes

    NASA Astrophysics Data System (ADS)

    Jiang, C. H.; Nakane, T.; Kumakura, H.

    2005-12-01

    A series of Fe-clad MgxB2 tapes with x varying from 0.5 to 1.2 was prepared by the in situ powder-in-tube method. Slightly Mg-deficient samples showed higher Jc in high magnetic fields, whereas samples with stoichiometric Mg or a slight excess of Mg exhibited better Jc in the low-field region. The sample with x =0.9 showed the best Jc in the applied magnetic field. The MgB2 core was porous in Mg-deficient tapes but with smaller grain sizes than the samples with a slight Mg excess due to insufficient grain growth. Some fine nanometer size grains were also observed in the B-rich samples. The enhanced grain boundary pinning due to the smaller grain size may explain the superior high-field Jc property of the slightly Mg-deficient MgB2 tapes. Our results indicate that preparing MgB2 samples with a slight excess of Mg may not be advantageous when developing devices for high-field applications.

  9. Understanding Marine Mussel Adhesion

    SciTech Connect

    H. G. Silverman; F. F. Roberto

    2007-12-01

    In addition to identifying the proteins that have a role in underwater adhesion by marine mussels, research efforts have focused on identifying the genes responsible for the adhesive proteins, environmental factors that may influence protein production, and strategies for producing natural adhesives similar to the native mussel adhesive proteins. The production-scale availability of recombinant mussel adhesive proteins will enable researchers to formulate adhesives that are waterimpervious and ecologically safe and can bind materials ranging from glass, plastics, metals, and wood to materials, such as bone or teeth, biological organisms, and other chemicals or molecules. Unfortunately, as of yet scientists have been unable to duplicate the processes that marine mussels use to create adhesive structures. This study provides a background on adhesive proteins identified in the blue mussel, Mytilus edulis, and introduces our research interests and discusses the future for continued research related to mussel adhesion.

  10. Understanding Marine Mussel Adhesion

    PubMed Central

    Roberto, Francisco F.

    2007-01-01

    In addition to identifying the proteins that have a role in underwater adhesion by marine mussels, research efforts have focused on identifying the genes responsible for the adhesive proteins, environmental factors that may influence protein production, and strategies for producing natural adhesives similar to the native mussel adhesive proteins. The production-scale availability of recombinant mussel adhesive proteins will enable researchers to formulate adhesives that are water-impervious and ecologically safe and can bind materials ranging from glass, plastics, metals, and wood to materials, such as bone or teeth, biological organisms, and other chemicals or molecules. Unfortunately, as of yet scientists have been unable to duplicate the processes that marine mussels use to create adhesive structures. This study provides a background on adhesive proteins identified in the blue mussel, Mytilus edulis, and introduces our research interests and discusses the future for continued research related to mussel adhesion. PMID:17990038

  11. Affine transformations from aerial photos to computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Peet, F. G.; Mack, A. R.; Crosson, L. S.

    1974-01-01

    During the development of a project to estimate wheat production, it became necessary to pull data, corresponding to particular fields in a test site, off an ERTS computer compatible tape. Aerial photographs and topographic maps were on hand for the test site. A method was devised, using an affine transformation, to relate the aerial photographs or topographic maps to the tapes. One can thereby access data on the tape corresponding to regions covered by only a few pixels. The theory can be used for the registration of two tapes for the same area and for the geometric correction of images.

  12. Specification for wide channel bandwidth one-inch video tape

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1988-01-01

    Standards and controls are established for the procurement of wide channel bandwidth one inch video magnetic recording tapes for Very Long Base Interferometer (VLBI) system applications. The Magnetic Tape Certification Facility (MTCF) currently maintains three specifications for the Quality Products List (QPL) and acceptance testing of magnetic tapes. NASA-TM-79724 is used for the QPL and acceptance testing of new analog tapes; NASA-TM-80599 is used for QPL and acceptance testing of new digital tapes; and NASA-TM-100702 is used for the QPL and acceptance testing of new IBM/IBM compatible 3480 magnetic tape cartridges. This specification will be used for the QPL and acceptance testing of new wide channel bandwidth one inch video magnetic recording tapes. The one inch video tapes used by the Jet Propulsion Lab., the Deep Space Network and the Haystack Observatory will be covered by this specification. These NASA stations will use the video tapes for their VLBI system applications. The VLBI system is used for the tracking of quasars and the support of interplanetary exploration.

  13. Reel-to-reel substrate tape polishing system

    DOEpatents

    Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei

    2005-06-21

    Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.

  14. Tape-cast sensors and method of making

    DOEpatents

    Mukundan, Rangachary; Brosha, Eric L.; Garzon, Fernando H.

    2009-08-18

    A method of making electrochemical sensors in which an electrolyte material is cast into a tape. Prefabricated electrodes are then partially embedded between two wet layers of the electrolyte tape to form a green sensor, and the green sensor is then heated to sinter the electrolyte tape around the electrodes. The resulting sensors can be used in applications such as, but not limited to, combustion control, environmental monitoring, and explosive detection. A electrochemical sensor formed by the tape-casting method is also disclosed.

  15. Mechanism for the uniaxial strain dependence of the critical current in practical REBCO tapes

    NASA Astrophysics Data System (ADS)

    Osamura, Kozo; Machiya, Shutaro; Hampshire, Damian P.

    2016-06-01

    In order to elucidate the effect of uniaxial strain on the critical current of practical REBCO tapes (REBa2Cu3O7-d , RE = Y and Gd) fabricated by Superpower and SuNAM, two types of critical current measurements were carried out. In the first, the tape sample was attached directly to a universal testing machine and pulled under a tensile load. In the second, the tape was soldered to a Cu-Be springboard and then attached to the testing machine and then pushed or pulled in order to apply both tensile and compressive strains to the tape sample. An inverse parabolic behaviour was observed for the uniaxial strain dependence of the critical current of both tapes. Using synchrotron radiation, the local strain exerted on the REBCO layer was measured at room temperature under the conditions used for the two techniques for making I c measurements. On the basis of these room temperature data, the local strain exerted on the REBCO layer at 77 K was numerically evaluated. A one-dimensional chain model for current flow in the REBCO material with fractional lengths of A-domains and B-domains oriented along the uniaxial strain direction is proposed. The model can explain the parabolic strain behaviour of the critical current and shows that the strain at which the peak in I c occurs, is not only determined by pre-compression or pre-tension on the superconductor at the operating temperature, but also by the ratio of the fractional amounts of the two domains.

  16. Micrometric periodic assembly of magnetotactic bacteria and magnetic nanoparticles using audio tapes

    NASA Astrophysics Data System (ADS)

    Godoy, M.; Moreno, A. J.; Jorge, G. A.; Ferrari, H. J.; Antonel, P. S.; Mietta, J. L.; Ruiz, M.; Negri, R. M.; Pettinari, M. J.; Bekeris, V.

    2012-02-01

    We report micrometric periodic assembly of live and dead magnetotactic bacteria, Magnetospirillum magneticum AMB-1, which synthesize chains of magnetic nanoparticles inside their bodies, and of superparamagnetic Fe3O4 and ferromagnetic CoFe2O4 nanoparticles in aqueous suspensions using periodically magnetized audio tapes. The distribution of the stray magnetic field at the surface of the tapes was determined analytically and experimentally by magneto-optic imaging. Calculations showed that the magnetic field close to the tape surface was of the order of 100 mT, and the magnetic field gradient was larger than 1 T mm-1. Drops of aqueous solutions were deposited on the tapes, and bacteria and particles were trapped at locations where magnetic energy is minimized, as observed using conventional optical microscopy. Suspensions of M. magneticum AMB-1 treated with formaldehyde and kanamycin were studied, and patterns of trapped dead bacteria indicated that magnetic forces dominate over self-propelling forces in these experiments, in accordance with calculated values. The behavior of the different types of samples is discussed.

  17. Effects of elastic taping, non-elastic taping and static stretching on recovery after intensive eccentric exercise.

    PubMed

    Boobphachart, Disaphon; Manimmanakorn, Nuttaset; Manimmanakorn, Apiwan; Thuwakum, Worrawut; Hamlin, Michael J

    2017-01-25

    The purpose of this study was to compare the effect of elastic tape (Kinesio tape) to placebo tape or static stretching on delayed onset muscle soreness. Fifty-one untrained female healthy volunteers were randomly assigned into three groups (n = 17/group), elastic tape, placebo tape and stretching group. Muscle soreness was induced by 4 sets of 25 maximal isokinetic (60°.s(-1)) eccentric contractions of dominant quadriceps on an isokinetic dynamometer. Compared with placebo tape, the elastic tape participants had less muscle soreness at 72 h post-exercise (p = 0.01). The elastic tape also increased isometric strength at 72 h post-exercise compared with the placebo (p = 0.03) and stretching group (p = 0.02). However, there was little effect between groups for changes in thigh circumference, jumping, pressure pain threshold, rate of perceived exertion, creatine kinase activity and joint motion. Elastic taping increased muscle strength recovery and reduced muscle soreness after intensive exercise.

  18. Design parameters and current fabrication approaches for developing bioinspired dry adhesives.

    PubMed

    del Campo, Aránzazu; Arzt, Eduard

    2007-02-12

    The attachment pads of some beetles, spiders, flies, and geckos are covered by a dense array of long hairs with characteristic geometries. This curious surface topography allows them to firmly attach to and easily release from almost any kind of surface. In a technological context, such reversible adhesion could enable robots to walk along walls or ceilings, or lead to new medical devices, disposable plasters, reusable adhesive tapes, etc. Artificial fibrillar surfaces mimicking nature's design have been recently fabricated, but their adhesion performance is still far from that of natural systems. This review describes the progress in this field during the last few years and discusses the issues pending for the future.

  19. Fabrication and characterization of Ag-clad Bi-2223 tapes.

    SciTech Connect

    Balachandran, U.

    1999-04-20

    The powder-in-tube (PIT) technique was used to fabricate multifilament (Bi,Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub y} (Bi-2223) superconducting tapes. Transport current properties of these tapes were enhanced by increasing the packing density of the precursor powder and improving the mechanical deformation condition. A critical current (I{sub c}) of > 35 A in long lengths (> 200 m) tapes has been achieved. In measuring the dependence of critical current density on magnetic field and temperature for the optimally processed tapes, we found a J{sub c} of > 10{sup 4} A/cm{sup 2} at 20 K in magnetic fields up to 3 T and parallel to the c-axis, which is of interest for use in refrigerator-cooled magnets. I{sub c} declined exponentially when an external field was applied perpendicular to the tape surface at 77 K. Mechanical stability was tested for tapes sheathed with pure Ag and Ag-Mg alloy. Tapes made with pure Ag sheathing can withstand a tensile stress of {approx}20 MPa with no detrimental effect on I{sub c} values. Mechanical performance was improved by using Ag-Mg alloy sheathing: values of transport critical current began to decrease at the tensile stress of {approx} 100 MPa. Transport current measurements on tapes wound on a mandrel of 3.81 cm (1.5 in.) diameter at 30{degree} to the longitudinal axis, showed a reduction of {approx} 10% in I{sub c} values for pure Ag-sheathed tapes and 5% reduction in I{sub c} values for Ag-Mg sheathed tapes, compared with the I{sub c} values of as-coiled tapes.

  20. Micro/Nanostructured Films and Adhesives for Biomedical Applications.

    PubMed

    Lee, Jungkyu K; Kang, Sung Min; Yang, Sung Ho; Cho, Woo Kyung

    2015-12-01

    The advanced technologies available for micro/nanofabrication have opened new avenues for interdisciplinary approaches to solve the unmet medical needs of regenerative medicine and biomedical devices. This review highlights the recent developments in micro/nanostructured adhesives and films for biomedical applications, including waterproof seals for wounds or surgery sites, drug delivery, sensing human body signals, and optical imaging of human tissues. We describe in detail the fabrication processes required to prepare the adhesives and films, such as tape-based adhesives, nanofilms, and flexible and stretchable film-based electronic devices. We also discuss their biomedical functions, performance in vitro and in vivo, and the future research needed to improve the current systems.

  1. Tape Recorders and the Commuter Student: Bypassing the Red Pen.

    ERIC Educational Resources Information Center

    Kates, Ronald

    1998-01-01

    Discusses several ways in which tape-recorded responses by the instructor to student writing can benefit commuter students. Discusses how the audio cassette responses are paired with a series of questions on the writing process and how the author shapes his tape-recorded comments. Notes student responses about the advantages of this approach. (SR)

  2. Design Your Organization's Own Slide-Tape Show

    ERIC Educational Resources Information Center

    Tilden, Scott W.

    1975-01-01

    Slide-tape shows offer a relatively inexpensive, easy-to-assemble means of informing a wide variety of groups interested in education. This article outlines a seven-step procedure to produce a coherent, professional-looking slide-tape presentation. (DS)

  3. 75 FR 14628 - Pressure Sensitive Plastic Tape From Italy; Determination

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-26

    ... COMMISSION Pressure Sensitive Plastic Tape From Italy; Determination On the basis of the record \\1\\ developed... antidumping duty finding on pressure sensitive plastic tape from Italy would be likely to lead to continuation... Commission are contained in USITC Publication 4128 (March 2010), entitled Pressure Sensitive Plastic...

  4. Library and Reference Applications: Census Tapes and Printed Reports.

    ERIC Educational Resources Information Center

    Anders, Mary Edna

    Census tapes are not a ready reference tool and must be supported by appropriate program tapes. However, census materials provide the single, most important sources of information and measures which, properly used, provide a better understanding of our society. In utilizing census products, librarians need to fill the role of a user, as well as…

  5. A CLASSIFICATION AND RETRIEVAL SYSTEM FOR RECORDED FOREIGN LANGUAGE TAPES.

    ERIC Educational Resources Information Center

    KAY, J.B.; JAMESON, A.

    A CLASSIFICATION SYSTEM FOR FOREIGN LANGUAGE RECORDINGS, DEVISED FOR USE AT THE UNIVERSITY OF ESSEX, IS DESCRIBED IN THIS ARTICLE. CODING AND CROSS-REFERENCE SYSTEMS FOR THE VARIOUS CATEGORIES OF TAPES ARE OUTLINED, AND SPECIFIC EXAMPLES ARE INCLUDED. APPENDED IS A LIST OF TAPE REFERENCE CODES. THE SYSTEM OUTLINED IS NOT CONSIDERED IDEAL, BUT IT…

  6. Tape the Teacher: Easier Field Trips for Large Classes

    ERIC Educational Resources Information Center

    Carter, Lynne; And Others

    1974-01-01

    Describes a tape-guided field trip that has been used successfully with college biology students in the University of California Botanical Garden. This program enables large numbers of students to make individual biological observations in the field with the aid of a specially tailored, taped guide. (JR)

  7. OCLC-MARC Tape Processing: A Functional Analysis.

    ERIC Educational Resources Information Center

    Miller, Bruce Cummings

    1984-01-01

    Analyzes structure of, and data in, the OCLC-MARC record in the form delivered via OCLC's Tape Subscription Service, and outlines important processing functions involved: "unreadable tapes," duplicate records and deduping, match processing, choice processing, locations processing, "automatic" and "input" stamps,…

  8. A Tape Method for Fast Characterization and Identification of Active Pharmaceutical Ingredients in the 2-18 THz Spectral Range

    NASA Astrophysics Data System (ADS)

    Kissi, Eric Ofosu; Bawuah, Prince; Silfsten, Pertti; Peiponen, Kai-Erik

    2015-03-01

    In order to find counterfeit drugs quickly and reliably, we have developed `tape method' a transmission spectroscopic terahertz (THz) measurement technique and compared it with a standard attenuated total reflection (ATR) THz spectroscopic measurement. We used well-known training samples, which include commercial paracetamol and aspirin tablets to check the validity of these two measurement techniques. In this study, the spectral features of some active pharmaceutical ingredients (APIs), such as aspirin and paracetamol are characterized for identification purpose. This work covers a wide THz spectral range namely, 2-18 THz. This proposed simple but novel technique, the tape method, was used for characterizing API and identifying their presence in their dosage forms. By comparing the spectra of the APIs to their dosage forms (powder samples), all distinct fingerprints present in the APIs are also present in their respective dosage forms. The positions of the spectral features obtained with the ATR techniques were akin to that obtained from the tape method. The ATR and the tape method therefore, complement each other. The presence of distinct fingerprints in this spectral range has highlighted the possibility of developing fast THz sensors for the screening of pharmaceuticals. It is worth noting that, the ATR method is applicable to flat faced tablets whereas the tape method is suitable for powders in general (e.g. curved surface tablets that require milling before measurement). Finally, we have demonstrated that ATR techniques can be used to screen counterfeit antimalarial tablets.

  9. Fabrication and characteristics of a test magnet from HTS Bi-2223 silver-clad tapes

    SciTech Connect

    Haldar, P.; Hoehn, J.G. Jr.; Motowidlo, L.R.; Iwasa, Y.

    1993-07-01

    Critical currents of powder-in-tube processed silver-clad Bi-2223 short tape samples and coils have been measured at liquid nitrogen (77 K), liquid neon (27 K) and liquid helium (4.2 K) temperatures. The short samples have been characterized in fields up to 20 T and indicate a large anisotropy at 27 K with resistive behavior above 15 T in the worst field direction. A test magnet consisting of pancake coils generated magnetic fields greater than 1.0, 0.7 and 0.11 T at 4.2 K, 27 K and 77 K respectively. The ctest magnet generates significant self-fields in background fields up to 14.5 T at 4.2 K and 27 K. Optimization of thermo-mechanical process parameters have yielded J{sub c}`s in the superconducting core > 4.0 {times} 10{sup 4} A/cm{sup 2} at 77 K, zero field and > 2.0 {times} 10{sup 5} A/cm{sup 2} at 4.2 K, zero field for short tape samples. Long lengths (>30 m) of silver-clad tape superconductors have also been fabricated and tested to carry significant amounts of current (J{sub c} core > 10,000 A/cm{sup 2}) at 77 K. Overall J{sub c} of short and long samples and characteristics of the test magnet are reported.

  10. Functionally Graded Adhesives

    DTIC Science & Technology

    2009-11-01

    ASTM 907-05. Standard Terminology of Adhesives. West Conshohocken, PA, May 2005. 4. 3M Scotch-Grip Nitrile High Performance Rubber & Gasket Adhesive...distribution is unlimited. 13. SUPPLEMENTARY NOTES 14. ABSTRACT The goal of this project was to increase rubber to metal adhesion in Army materials using...1 Figure 2. Steel and rubber

  11. PH dependent adhesive peptides

    SciTech Connect

    Tomich, John; Iwamoto, Takeo; Shen, Xinchun; Sun, Xiuzhi Susan

    2010-06-29

    A novel peptide adhesive motif is described that requires no receptor or cross-links to achieve maximal adhesive strength. Several peptides with different degrees of adhesive strength have been designed and synthesized using solid phase chemistries. All peptides contain a common hydrophobic core sequence flanked by positively or negatively charged amino acids sequences.

  12. Portable digital pressure indicator for calibrating magnetic tape recorders

    NASA Technical Reports Server (NTRS)

    Mccormick, Royce F.; Leighty, Bradley D.

    1989-01-01

    The design of a portable Digital Pressure Indicator (DPI) to be used for calibrating the pressure systems on Langley's magnetic tape recorders is described. High-speed magnetic tape recorders require pressure (0 to 20 psig) for providing an air cushion across the tape guides and a slight vacuum (30 inch H2O) for maintaining the proper number of tape loops in the advance and feed chamber. The DPI is a hand-held device that can be quickly coupled to a magnetic tape recorder and includes a two-position switch for selecting either measured pressure or vacuum, to be displayed digitally in engineering units (psig or inches H2O). The DPI is currently in use in Langley's Analysis and Computation Division.

  13. Mini-review: barnacle adhesives and adhesion.

    PubMed

    Kamino, Kei

    2013-01-01

    Barnacles are intriguing, not only with respect to their importance as fouling organisms, but also in terms of the mechanism of underwater adhesion, which provides a platform for biomimetic and bioinspired research. These aspects have prompted questions regarding how adult barnacles attach to surfaces under water. The multidisciplinary and interdisciplinary nature of the studies makes an overview covering all aspects challenging. This mini-review, therefore, attempts to bring together aspects of the adhesion of adult barnacles by looking at the achievements of research focused on both fouling and adhesion. Biological and biochemical studies, which have been motivated mainly by understanding the nature of the adhesion, indicate that the molecular characteristics of barnacle adhesive are unique. However, it is apparent from recent advances in molecular techniques that much remains undiscovered regarding the complex event of underwater attachment. Barnacles attached to silicone-based elastomeric coatings have been studied widely, particularly with respect to fouling-release technology. The fact that barnacles fail to attach tenaciously to silicone coatings, combined with the fact that the mode of attachment to these substrata is different to that for most other materials, indicates that knowledge about the natural mechanism of barnacle attachment is still incomplete. Further research on barnacles will enable a more comprehensive understanding of both the process of attachment and the adhesives used. Results from such studies will have a strong impact on technology aimed at fouling prevention as well as adhesion science and engineering.

  14. Investigating Delamination Migration in Composite Tape Laminates

    NASA Technical Reports Server (NTRS)

    Ratcliffe, James G.; DeCarvalho, Nelson V.

    2014-01-01

    A modification to a recently developed test specimen designed to investigate migration of a delamination between neighboring ply interfaces in tape laminates is presented. The specimen is a cross-ply laminated beam consisting of 40 plies with a polytetrafluoroethylene insert spanning part way along its length. The insert is located between a lower 0-degree ply (specimen length direction) and a stack of four 90-degree plies (specimen width direction). The modification involved a stacking sequence that promotes stable delamination growth prior to migration, and included a relocation of the insert from the specimen midplane to the interface between plies 14 and 15. Specimens were clamped at both ends onto a rigid baseplate and loaded on their upper surface via a piano hinge assembly, resulting in a predominantly flexural loading condition. Tests were conducted with the load-application point positioned at various locations along a specimen's span. This position affected the sequence of damage events during a test.

  15. BACKUP -- Recovering from incremental tape backups

    NASA Astrophysics Data System (ADS)

    Allan, P. M.

    The importance of making regular backups of your disks in well known, but it can be very frustrating to have a head crash and then discover that you cannot recover from your backups because the manuals do not tell you what to do. The DEC documentation covers most possibilities, but not the case where a removable pack is copied to a new pack, the new pack is then used as the current pack, and incremental backups to tape are then made. This situation is a fairly common one when you have two or more removable disk drives. This note covers backup and recovery in general terms, and details exactly what to do in the above mentioned case.

  16. Adhesion of microchannel-based complementary surfaces.

    PubMed

    Singh, Arun K; Bai, Ying; Nadermann, Nichole; Jagota, Anand; Hui, Chung-Yuen

    2012-03-06

    We show that highly enhanced and selective adhesion can be achieved between surfaces patterned with complementary microchannel structures. An elastic material, poly(dimethylsiloxane) (PDMS), was used to fabricate such surfaces by molding into a silicon master with microchannel profiles patterned by photolithography. We carried out adhesion tests on both complementary and mismatched microchannel/micropillar surfaces. Adhesion, as measured by the energy release rate required to propagate an interfacial crack, can be enhanced by up to 40 times by complementary interfaces, compared to a flat control, and slightly enhanced for some special noncomplementary samples, despite the nearly negligible adhesion for other mismatched surfaces. For each complementary surface, we observe defects in the form of visible striations, where pillars fail to insert fully into the channels. The adhesion between complementary microchannel surfaces is enhanced by a combination of a crack-trapping mechanism and friction between a pillar and channel and is attenuated by the presence of defects.

  17. Effect of 3 Different Applications of Kinesio Taping Denko® on Electromyographic Activity: Inhibition or Facilitation of the Quadriceps of Males During Squat Exercise

    PubMed Central

    Serrão, Júlio C.; Mezêncio, Bruno; Claudino, João G.; Soncin, Rafael; Miyashiro, Pedro L. Sampaio; Sousa, Eric P.; Borges, Eduardo; Zanetti, Vinícius; Phillip, Igor; Mochizuki, Luiz; Amadio, Alberto C.

    2016-01-01

    Kinesio taping consists of a technique which uses the application of an elastic adhesive tape. It has become a widely used rehabilitation modality for the prevention and treatment of musculoskeletal disorders. The objective of this study was to verify the effect of the application of Kinesio Taping Denko® in three conditions (facilitation, inhibition, and placebo) on the electromyographic activity of the quadriceps and hamstrings muscles on facilitating or inhibiting the muscle function and on the perceived exertion during the barbell back squat exercise in healthy male subjects. Methods: It was a randomized, single-blinded and controlled study in which 18 males (28.0 ± 6.7 years old; 85.8 ± 8.2 kg mass; 1.80 ± 0.07 m tall; 0.97 ± 0.04 m lower limb length) performed barbell back squat exercise with different conditions of Kinesio Taping Denko® applications: Facilitation, inhibition and placebo. Previous to the mentioned conditions, all individuals were assessed without applying kinesio Taping Denko® during the exercise. OMNI scale was used after each set for perceived exertion evaluation. No differences (p < 0.05) in the electromyographic activity of the biceps femoris, vastus lateralis and vastus medialis or OMNI scale were recorded under any conditions. The results show that the kinesio taping denko®may not alter the magnitude of the electromyography activity of vastus lateralis, vastus medialis, and biceps femoris during the squat exercise. Furthermore, the perceived exertion was not affected by the kinesio taping denko® application. Key points Researchers involved in collecting data in this study have no financial or personal interest in the outcome of results or the sponsor. The perceived exertion was not affected by the kinesiology taping application. Kinesiology taping application may not alter the magnitude of EMG activity of vastuslateralis, vastusmedialis, and biceps femoris during the barbell back squat exercise. Electromyographic activity of

  18. Nanosized Cr2O3 as pinning center in (Bi,Pb)-Sr-Ca-Cu-O superconductor tapes

    NASA Astrophysics Data System (ADS)

    Lee, G. H.; Abd-Shukor, R.

    2013-05-01

    Nanosized Cr2O3 (6 nm) has been introduced into (Bi,Pb)-Sr-Ca-Cu-O/Ag tapes fabricated by the powderin-tube method. The starting powder with composition (Bi,Pb)2Sr2Ca2Cu3O10(Cr2O3)0.05 was prepared by the solid state reaction method. The superconductor tapes with thickness of about 0.3 mm and length about 2 cm were heated at 845°C for 96, 144, 192 and 240 h. The samples were characterized by the four point probe electrical measurements, X-ray powder diffraction method and scanning electron microscopy. The transport critical current density, Jc was measured from 30 to 65 K using the 1 μ/cm criterion. The highest Jc was obtained for the tape heated for 240 h with Jc = 1700 A/cm2 at 30 K. XRD patterns showed that the samples consisted of the 2212 and 2223 phase. SEM micrographs showed the plat-like structure. The role of nano-Cr2O3 in the superconductor system is discussed. The size of the nanoparticle (R) was larger than the coherence length, ξ but smaller than the penetration depth, λ(ξ< R <λ). The temperature dependent Jc from 30 to 65 K showed a linear relation for all except for the tapes heated at 240 h. Using the self-field approximation together with the Jc dependence on temperature, it was observed that between 30 and 65 K the characteristic length (Lc) associated with the pinning force Fp is approximately the same as the average grain size (Rg) in all samples except for the tapes heated for 240 h where Rg < Lc. This shows that a change in the flux pinning mechanism occurred in the tapes when the heating time was prolonged.

  19. Whole animal measurements of shear and adhesive forces in adult tree frogs: insights into underlying mechanisms of adhesion obtained from studying the effects of size and scale.

    PubMed

    Barnes, W Jon P; Oines, Christine; Smith, Joanna M

    2006-11-01

    This allometric study of adhesion in 15 Trinidadian tree frog species investigates how relationships between length, area and mass limit the ability of adult frog species of different sizes to adhere to inclined and overhanging surfaces. Our experiments show that hylid frogs possess an area-based wet adhesive system in which larger species are lighter than expected from isometry and adhere better than expected from their toe pad area. However, in spite of these adaptations, larger species adhere less well than smaller species. In addition to these adhesive forces, tree frogs also generate significant shear forces that scale with mass, suggesting that they are frictional forces. Toe pads detach by peeling and frogs have strategies to prevent peeling from taking place while they are adhering to surfaces, including orienting themselves head-up on slopes. The scaling of tree frog adhesion is also used to distinguish between different models for adhesion, including classic formulae for capillarity and Stefan adhesion. These classic equations grossly overestimate the adhesive forces that tree frogs produce. More promising are peeling models, designed to predict the pull-off forces of adhesive tape. However, more work is required before we can qualitatively and quantitatively describe the adhesive mechanism of tree frogs.

  20. Fabrication and characterization of high-T(sub c) tapes and coils made from Ag-clad Bi-2223 superconductors

    NASA Astrophysics Data System (ADS)

    Balachandran, U.; Iyer, A. N.; Youngdahl, C. A.; Motowidlo, L. R.; Hoehn, J. G., Jr.; Haldar, P.

    1993-07-01

    Prereacted Pb-doped Bi-Sr-Ca-Cu-O powders were packed into Ag tubes, drawn, rolled, and given intermediate heat treatment to prepare long lengths of Ag-clad Bi-2223 superconductor tapes. With the use of improved process conditions, transport critical current density (J(sub c)) values exceeding 10(exp 5) A/sq cm at 4.2 K and 27 K, and greater than 4 x 10(exp 4) A/sq cm at 77 K, were obtained in zero applied field with short tape samples. Detailed microstructural analysis and J(sub c) measurements in applied fields up to 20 T are reported. Rolled tapes were cut into lengths of up to 10 m, and several such tapes were used in parallel to fabricate small superconducting pancake coils by the 'wind-and-react' technique. Recently, we fabricated a test magnet with six pancake coils, each containing three 10-m lengths of rolled tapes and tested at 4.2, 27, and 77 K as a function of applied fields up to 14.5 T. A maximum generated field of 1.25 T was measured in zero applied field at 4.2 T. Detailed measurements made on the pancake coils and test magnets are reported in this paper.

  1. An Experimental Investigation of Damaged Arresting Gear Tapes for the Langley Aircraft Landing Dynamics Facility

    NASA Technical Reports Server (NTRS)

    Mason, Angela J.

    1999-01-01

    An experimental investigation was performed on damaged arresting gear tapes at the Langley Aircraft Landing Dynamics Facility. The arrestment system uses five pairs of tapes to bring the test carriage to a halt. The procedure used to determine when to replace the tapes consists of a close evaluation of each of the 10 tapes after each run. During this evaluation, each tape is examined thoroughly and any damage observed on the tape is recorded. If the damaged tape does not pass the inspection, the tape is replaced with a new one. For the past 13 years, the most commonly seen damage types are edge fray damage and transverse damage. Tests were conducted to determine the maximum tensile strength of a damaged arresting gear tape specimen. The data indicate that tapes exhibiting transverse damage can withstand higher loads than tapes with edge fray damage.

  2. Improving the Spacelab mass memory unit tape layout with a simulation model

    NASA Technical Reports Server (NTRS)

    Noneman, S. R.

    1984-01-01

    A tape drive called the Mass Memory Unit (MMU) stores software used by Spacelab computers. MMU tape motion must be minimized during typical flight operations to avoid a loss of scientific data. A projection of the tape motion is needed for evaluation of candidate tape layouts. A computer simulation of the scheduled and unscheduled MMU tape accesses is developed for this purpose. This simulation permits evaluations of candidate tape layouts by tracking and summarizing tape movements. The factors that affect tape travel are investigated and a heuristic is developed to find a good tape layout. An improved tape layout for Spacelab I is selected after the evaluation of fourteen candidates. The simulation model will provide the ability to determine MMU layouts that substantially decrease the tape travel on future Spacelab flights.

  3. Tape Transfer Atomization Patterning of Liquid Alloys for Microfluidic Stretchable Wireless Power Transfer

    PubMed Central

    Jeong, Seung Hee; Hjort, Klas; Wu, Zhigang

    2015-01-01

    Stretchable electronics offers unsurpassed mechanical compliance on complex or soft surfaces like the human skin and organs. To fully exploit this great advantage, an autonomous system with a self-powered energy source has been sought for. Here, we present a new technology to pattern liquid alloys on soft substrates, targeting at fabrication of a hybrid-integrated power source in microfluidic stretchable electronics. By atomized spraying of a liquid alloy onto a soft surface with a tape transferred adhesive mask, a universal fabrication process is provided for high quality patterns of liquid conductors in a meter scale. With the developed multilayer fabrication technique, a microfluidic stretchable wireless power transfer device with an integrated LED was demonstrated, which could survive cycling between 0% and 25% strain over 1,000 times. PMID:25673261

  4. High-Throughput Method of Whole-Brain Sectioning, Using the Tape-Transfer Technique

    PubMed Central

    Pinskiy, Vadim; Jones, Jamie; Tolpygo, Alexander S.; Franciotti, Neil; Weber, Kevin; Mitra, Partha P.

    2015-01-01

    Cryostat sectioning is a popular but labor-intensive method for preparing histological brain sections. We have developed a modification of the commercially available CryoJane tape collection method that significantly improves the ease of collection and the final quality of the tissue sections. The key modification involves an array of UVLEDs to achieve uniform polymerization of the glass slide and robust adhesion between the section and slide. This report presents system components and detailed procedural steps, and provides examples of end results; that is, 20μm mouse brain sections that have been successfully processed for routine Nissl, myelin staining, DAB histochemistry, and fluorescence. The method is also suitable for larger brains, such as rat and monkey. PMID:26181725

  5. Tape extensometer sensitivity and reliability. [Climax fuel storage at NTS

    SciTech Connect

    Yow, J.L. Jr.; Wilder, D.G.

    1981-09-21

    The Spent Fuel Test-Climax is a test of retrievable storage in granite of spent nuclear reactor fuel. The rock has been instrumented to measure temperatures, stress changes, and displacements. Periodic tape extensometer readings provide test drift convergence data. Vertical and horizontal tape readings are made at five locations in each of two 3.4m x 3.4m (11 ft x 11 ft) drifts and six locations in a 4.6m x 6.2m (15 ft x 20.5 ft) drift. The sensitivity of the readings to temperature effects, errors in temperature corrections, change of steel tape, and change of operator has been examined. Calculated corrections for temperature-induced changes in distance range from 0.001 in. to 0.003 in.//sup 0/C. A tape changeout evidenced both a systematic error apparently due to slight changes in tape registration during punching and to nonidentical location of punched holes in the two tapes and a random error due to variability of reading and punching operations. These errors were corrected by making duplicate measurements for the tapes. Tape readings by the same operator have been repeatable within +-0.001 in. in the smaller drifts and +-0.002 in. in the larger. Different operators have been able to repeat readings to within +-0.004 in. (usually within +-0.002 in.) with generally consistent direction of offset between operators. Corrections of readings and review of plotted data show the tape extensometer to be a reliable instrument for tunnel convergence measurements.

  6. Japanese Science Films; a Descriptive and Evaluative Catalog of: 16mm Motion Pictures, 8mm Cartridges, and Video Tapes.

    ERIC Educational Resources Information Center

    Newren, Edward F., Ed.

    One hundred and eighty Japanese 16mm motion pictures, 8mm cartridges, and video tapes produced and judged appropriate for a variety of audience levels are listed in alphabetical order by title with descriptive and evaluative information. A subject heading list and a subject index to the film titles are included, as well as a sample of the…

  7. On the mechanical properties of bovine serum albumin (BSA) adhesives.

    PubMed

    Berchane, N S; Andrews, M J; Kerr, S; Slater, N K H; Jebrail, F F

    2008-04-01

    Biological adhesives, natural and synthetic, are of current active interest. These adhesives offer significant advantages over traditional sealant techniques, in particular, they are easier to use, and can play an integral part in the healing mechanism of tissue. Thus, biological adhesives can play a major role in medical applications if they possess adequate mechanical behavior and stability over time. In this work, we report on the method of preparation of bovine serum albumin (BSA) into a biological adhesive. We present quantitative measurements that show the effect of BSA concentration and cross-linker content on the bonding strength of BSA adhesive to wood. A comparison is then made with synthetic poly(glycidyl methacrylate) (PGMA) adhesive, and a commercial cyanoacrylate glue, which was used as a control adhesive. In addition, BSA samples were prepared and characterized for their water content, tensile strength, and elasticity. We show that on dry surface, BSA adhesive exhibits a high bonding strength that is comparable with non-biological commercial cyanoacrylate glues, and synthetic PGMA adhesive. Tensile testing on wet wood showed a slight increase in the bonding strength of BSA adhesive, a considerable decrease in the bonding strength of cyanoacrylate glue, and negligible adhesion of PGMA. Tests performed on BSA samples demonstrate that initial BSA concentration and final water content have a significant effect on the stress-strain behavior of the samples.

  8. Shear Strength of Conductive Adhesive Joints on Rigid and Flexible Substrates Depending on Adhesive Quantity

    NASA Astrophysics Data System (ADS)

    Hirman, Martin; Steiner, Frantisek

    2016-05-01

    This article deals with the impact of electrically conductive adhesive quantity on the shear strength of joints glued by adhesives "EPO-TEKⓇ H20S" and "MG8331S" on three types of substrates (FR-4, MELINEXⓇST504, DuPont™ PyraluxⓇAC). These joints were made by gluing chip resistors 1206, 0805 and 0603, with two curing profiles for each adhesive. Different thicknesses of stencil and reductions in the size of the hole in stencils were used for this experiment. These differences have an effect on the quantity of conductive adhesives which must be used on the samples. Samples were measured after the curing process by using a shear strength test applied by the device LabTest 3.030. This article presents the effects of different curing profiles, various types of substrates, and different quantities of adhesives on the mechanical strength of the joint.

  9. Freeze Tape Casting of Functionally Graded Porous Ceramics

    NASA Technical Reports Server (NTRS)

    Sofie, Stephen W.

    2007-01-01

    Freeze tape casting is a means of making preforms of ceramic sheets that, upon subsequent completion of fabrication processing, can have anisotropic and/or functionally graded properties that notably include aligned and graded porosity. Freeze tape casting was developed to enable optimization of the microstructures of porous ceramic components for use as solid oxide electrodes in fuel cells: Through alignment and grading of pores, one can tailor surface areas and diffusion channels for flows of gas and liquid species involved in fuel-cell reactions. Freeze tape casting offers similar benefits for fabrication of optimally porous ceramics for use as catalysts, gas sensors, and filters.

  10. Ice adhesion on super-hydrophobic surfaces

    NASA Astrophysics Data System (ADS)

    Kulinich, S. A.; Farzaneh, M.

    2009-06-01

    In this study, ice adhesion strength on flat hydrophobic and rough super-hydrophobic coatings with similar surface chemistry (based on same fluoropolymer) is compared. Glaze ice, similar to naturally accreted, was prepared on the surfaces by spraying super-cooled water microdroplets at subzero temperature. Ice adhesion was evaluated by spinning the samples at constantly increasing speed until ice delamination occurred. Super-hydrophobic surfaces with different contact angle hysteresis were tested, clearly showing that the latter, along with the contact angle, also influences the ice-solid adhesion strength.

  11. Desmosomal adhesion in vivo.

    PubMed

    Berika, Mohamed; Garrod, David

    2014-02-01

    Desmosomes are intercellular junctions that provide strong adhesion or hyper-adhesion in tissues. Here, we discuss the molecular and structural basis of this with particular reference to the desmosomal cadherins (DCs), their isoforms and evolution. We also assess the role of DCs as regulators of epithelial differentiation. New data on the role of desmosomes in development and human disease, especially wound healing and pemphigus, are briefly discussed, and the importance of regulation of the adhesiveness of desmosomes in tissue dynamics is considered.

  12. Reversible Thermoset Adhesives

    NASA Technical Reports Server (NTRS)

    Mac Murray, Benjamin C. (Inventor); Tong, Tat H. (Inventor); Hreha, Richard D. (Inventor)

    2016-01-01

    Embodiments of a reversible thermoset adhesive formed by incorporating thermally-reversible cross-linking units and a method for making the reversible thermoset adhesive are provided. One approach to formulating reversible thermoset adhesives includes incorporating dienes, such as furans, and dienophiles, such as maleimides, into a polymer network as reversible covalent cross-links using Diels Alder cross-link formation between the diene and dienophile. The chemical components may be selected based on their compatibility with adhesive chemistry as well as their ability to undergo controlled, reversible cross-linking chemistry.

  13. Adhesion at metal interfaces

    NASA Technical Reports Server (NTRS)

    Banerjea, Amitava; Ferrante, John; Smith, John R.

    1991-01-01

    A basic adhesion process is defined, the theory of the properties influencing metallic adhesion is outlined, and theoretical approaches to the interface problem are presented, with emphasis on first-principle calculations as well as jellium-model calculations. The computation of the energies of adhesion as a function of the interfacial separation is performed; fully three-dimensional calculations are presented, and universality in the shapes of the binding energy curves is considered. An embedded-atom method and equivalent-crystal theory are covered in the framework of issues involved in practical adhesion.

  14. Adhesives, silver amalgam.

    PubMed

    1995-09-01

    The most recent advancement in silver amalgam is use of resin formulations to bond metal to tooth both chemically &/or physically, Since, historically, amalgam has been used successfully without adhesion to tooth, obvious clinical question is: Why is bonding now desirable? Two major clinical reasons to bond are: (1) Adhesive can increase fracture resistance of amalgam restored teeth & decrease cusp fractures; & (2) Seal provided by adhesive can greatly decrease, & often eliminate post-operative sensitivity. Following report summarizes CRA laboratory study of shear bond strength & sealing capability of 23 commercial adhesives used to bond 2 types of silver amalgam to tooth structure.

  15. 13 point video tape quality guidelines

    SciTech Connect

    Gaunt, R.

    1997-05-01

    Until high definition television (ATV) arrives, in the U.S. we must still contend with the National Television Systems Committee (NTSC) video standard (or PAL or SECAM-depending on your country). NTSC, a 40-year old standard designed for transmission of color video camera images over a small bandwidth, is not well suited for the sharp, full-color images that todays computers are capable of producing. PAL and SECAM also suffers from many of NTSC`s problems, but to varying degrees. Video professionals, when working with computer graphic (CG) images, use two monitors: a computer monitor for producing CGs and an NTSC monitor to view how a CG will look on video. More often than not, the NTSC image will differ significantly from the CG image, and outputting it to NTSC as an artist works enables the him or her to see the images as others will see it. Below are thirteen guidelines designed to increase the quality of computer graphics recorded onto video tape. Viewing your work in NTSC and attempting to follow the below tips will enable you to create higher quality videos. No video is perfect, so don`t expect to abide by every guideline every time.

  16. Shuttle-Data-Tape XML Translator

    NASA Technical Reports Server (NTRS)

    Barry, Matthew R.; Osborne, Richard N.

    2005-01-01

    JSDTImport is a computer program for translating native Shuttle Data Tape (SDT) files from American Standard Code for Information Interchange (ASCII) format into databases in other formats. JSDTImport solves the problem of organizing the SDT content, affording flexibility to enable users to choose how to store the information in a database to better support client and server applications. JSDTImport can be dynamically configured by use of a simple Extensible Markup Language (XML) file. JSDTImport uses this XML file to define how each record and field will be parsed, its layout and definition, and how the resulting database will be structured. JSDTImport also includes a client application programming interface (API) layer that provides abstraction for the data-querying process. The API enables a user to specify the search criteria to apply in gathering all the data relevant to a query. The API can be used to organize the SDT content and translate into a native XML database. The XML format is structured into efficient sections, enabling excellent query performance by use of the XPath query language. Optionally, the content can be translated into a Structured Query Language (SQL) database for fast, reliable SQL queries on standard database server computers.

  17. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    SciTech Connect

    Grin, A.; Lstiburek, J.

    2014-09-01

    The goal of this research is to provide durable and long-term water management solutions using exterior insulating sheathing as part of the water management system. It is possible to tape or seal the joints in insulating sheathing to create a drainage plane and even an air control layer. There exists the material durability component of the tape as well as the system durability component being the taped insulating sheathing as the drainage plane. This measure guideline provides best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant issues were discussed with the group, which are required to make taped insulating sheathing a simple, long-term, and durable drainage plane: horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists use superior materials; and frequent installation inspection and regular trade training are required to maintain proper installation.

  18. Creating and Using Video Tapes for Cartographic Demonstrations.

    ERIC Educational Resources Information Center

    Andrews, Sona K.; Gersmehl, Philip J.

    1986-01-01

    Offers nine suggestions for video tape production and instructional use in a student laboratory for a cartography course. Briefly discusses costs and benefits, including more time for instructors to focus on specific techniques and individual questions. (TRS)

  19. Solar cell interconnection and packaging using tape carrier

    SciTech Connect

    Kim, N.P.; Stanbery, B.J.

    1991-06-04

    This paper describes an array of photovoltaic cells. It comprises: photovolatic cells having a ratio of mass to surface area of less than 60 milligrams/square centimeter; a dielectric tape having a carrier surface for supporting the photovoltaic cells; interconnect means including an electrical circuit for electrically interconnecting the photovoltaic cells, the interconnect means supported by the dielectric tape on the carrier surface, the electrical circuit including contact fingers; and means defining primary openings in the dielectric tape, a primary opening being associated with a contact finger and positioned such that the contact finger can be directed from below the carrier surface in the direction of the photovoltaic cells and electrically connected to a photovoltaic cell, a portion of both sides of the contact finger being substantially free of the dielectric tape. This patent also describes the array of the above claim, wherein the photovoltaic cells are tandem cells including an upper subcell and a lower subcell.

  20. 4. INTERIOR VIEW SHOWING CURRENT USE AS MAGNETIC TAPE STORAGE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. INTERIOR VIEW SHOWING CURRENT USE AS MAGNETIC TAPE STORAGE FACILITY; VIEW TO NORTHEAST. - Cape Canaveral Air Station, Launch Complex 17, Facility 36002, East end of Lighthouse Road, Cape Canaveral, Brevard County, FL

  1. ICI optical data storage tape: An archival mass storage media

    NASA Technical Reports Server (NTRS)

    Ruddick, Andrew J.

    1993-01-01

    At the 1991 Conference on Mass Storage Systems and Technologies, ICI Imagedata presented a paper which introduced ICI Optical Data Storage Tape. This paper placed specific emphasis on the media characteristics and initial data was presented which illustrated the archival stability of the media. More exhaustive analysis that was carried out on the chemical stability of the media is covered. Equally important, it also addresses archive management issues associated with, for example, the benefits of reduced rewind requirements to accommodate tape relaxation effects that result from careful tribology control in ICI Optical Tape media. ICI Optical Tape media was designed to meet the most demanding requirements of archival mass storage. It is envisaged that the volumetric data capacity, long term stability and low maintenance characteristics demonstrated will have major benefits in increasing reliability and reducing the costs associated with archival storage of large data volumes.

  2. 11. PAINTERS REMOVING MASKING TAPE, VIEW LOOKING SOUTH FROM BOTTOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. PAINTERS REMOVING MASKING TAPE, VIEW LOOKING SOUTH FROM BOTTOM FLOOR OF DRYDOCK NO. 5. - Naval Base Philadelphia-Philadelphia Naval Shipyard, Dry Dock No. 5, League Island, Philadelphia, Philadelphia County, PA

  3. 75 FR 8114 - Pressure Sensitive Plastic Tape From Italy

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-23

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Pressure Sensitive Plastic Tape From Italy AGENCY: United States International Trade Commission. ACTION: Revised schedule for the subject review. DATES: Effective Date: February 16, 2010. FOR...

  4. Accuracy testing of electric groundwater-level measurement tapes

    USGS Publications Warehouse

    Jelinski, Jim; Clayton, Christopher S.; Fulford, Janice M.

    2015-01-01

    The accuracy tests demonstrated that none of the electric-tape models tested consistently met the suggested USGS accuracy of ±0.01 ft. The test data show that the tape models in the study should give a water-level measurement that is accurate to roughly ±0.05 ft per 100 ft without additional calibration. To meet USGS accuracy guidelines, the electric-tape models tested will need to be individually calibrated. Specific conductance also plays a part in tape accuracy. The probes will not work in water with specific conductance values near zero, and the accuracy of one probe was unreliable in very high conductivity water (10,000 microsiemens per centimeter).

  5. Magnetic Imaging of Superconducting Tapes to Determine Current Flow

    NASA Astrophysics Data System (ADS)

    Mueller, Fred M.; Brown, David J.; Hawley, Marilyn E.; Brown, Geoffrey W.; Yates Coulter, J.

    2000-03-01

    We have developed a magnetic imaging system which yields quantitative information about the magnetic field near the surface of a superconducting tape while it is carrying current at liquid nitrogen temperatures. The imaging system is based on a mechanical scanner with motion coupled into a dewar and uses standard magnetoresistive read heads from computer hard disk drives as the sensor elements. We have numerically inverted the external magnetic field data from silver-coated YBCO tapes to derive the internal tape current densities. Preliminary results are consistent with the expected patterns in the tapes, obey sum rules, and exhibit time reversal symmetry. Preliminary current flow paths suggest that the current density can be non-uniform.

  6. 34. Perimeter acquisition radar building room #325, tape handler room ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    34. Perimeter acquisition radar building room #325, tape handler room - Stanley R. Mickelsen Safeguard Complex, Perimeter Acquisition Radar Building, Limited Access Area, between Limited Access Patrol Road & Service Road A, Nekoma, Cavalier County, ND

  7. Generation and physical characteristics of the LANDSAT-1, -2 and -3 MSS computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1977-01-01

    The generation and format of the LANDSAT 1, 2, and 3 system corrected multispectral scanner computer compatible tapes are discussed. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes. Also included in the discussion are geometric and radiometric corrections, tape formats, and the physical characteristics of the tape.

  8. 75 FR 17124 - Pressure Sensitive Plastic Tape from Italy: Notice of Continuation of Antidumping Duty Finding

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-05

    ... International Trade Administration Pressure Sensitive Plastic Tape from Italy: Notice of Continuation of... plastic tape (PSP Tape) from Italy would be likely to lead to continuation or recurrence of dumping and of... to be revoked. See Pressure Sensitive Plastic Tape from Italy: Final Results of Expedited...

  9. VIEW OF CABLES AND TAPES ASSOCIATED WITH ADRIVE CONTROL ROD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF CABLES AND TAPES ASSOCIATED WITH A-DRIVE CONTROL ROD SYSTEM, AT LEVEL +15’, DIRECTLY ABOVE PDP CONTROL ROOM, LOOKING NORTHWEST. THE CABLES FROM THE PDP ROOM GO THROUGH THE CONCRETE WALL, MAKE A RIGHT ANGLE TURN DOWNWARD, AND DESCEND INTO THE PDP CONTROL ROOM AS VERTICAL TAPES - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  10. Empirical Characterization of Unconstrained Tape Spring Deployment Dynamics

    DTIC Science & Technology

    2012-03-22

    panded from simple homogeneous materials into the lighter, stiffer composites such as S-glass and carbon fiber reinforced plastic (CFRP). Allowable...stiffer composites such as S-Glass and carbon fiber reinforced plastic (CFRP). Allowable thickness, layup count and layup orienta- tion continue to be...205 GPa for Young’s Modulus, and 0.29 for Poisson’s Ratio. E ν 3.1.1.2 CFRP Tape Springs. The carbon fiber reinforced plastic (CFRP) tape springs used

  11. FGGE/SBUV tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The FGGE/SBUV Level 2C data set consists of 12 9-track data tapes, each of which contains total ozone and ozone profile data for one calendar month grouped in files containing the data in a 6 hour synoptic time block. The data flow and quality checks in the production of this data set are described as well as the format of the data tapes and the accompanying shipping documents.

  12. Biomechanics of shear-sensitive adhesion in climbing animals: peeling, pre-tension and sliding-induced changes in interface strength

    PubMed Central

    2016-01-01

    Many arthropods and small vertebrates use adhesive pads for climbing. These biological adhesives have to meet conflicting demands: attachment must be strong and reliable, yet detachment should be fast and effortless. Climbing animals can rapidly and reversibly control their pads' adhesive strength by shear forces, but the mechanisms underlying this coupling have remained unclear. Here, we show that adhesive forces of stick insect pads closely followed the predictions from tape peeling models when shear forces were small, but strongly exceeded them when shear forces were large, resulting in an approximately linear increase of adhesion with friction. Adhesion sharply increased at peel angles less than ca 30°, allowing a rapid switch between attachment and detachment. The departure from classic peeling theory coincided with the appearance of pad sliding, which dramatically increased the peel force via a combination of two mechanisms. First, partial sliding pre-stretched the pads, so that they were effectively stiffer upon detachment and peeled increasingly like inextensible tape. Second, pad sliding reduces the thickness of the fluid layer in the contact zone, thereby increasing the stress levels required for peeling. In combination, these effects can explain the coupling between adhesion and friction that is fundamental to adhesion control across all climbing animals. Our results highlight that control of adhesion is not solely achieved by direction-dependence and morphological anisotropy, suggesting promising new routes for the development of controllable bio-inspired adhesives. PMID:27605165

  13. Calibration tests on magnetic tape lightning current detectors

    NASA Technical Reports Server (NTRS)

    Crouch, K. E.

    1980-01-01

    The low cost, passive, peak lightning current detector (LCD) invented at the NASA/Kennedy Space Center, uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. Test results show that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10% were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. The stopwatch technique is a simple, low cost means of obtaining LCD readouts and can be used in the field to obtain immediate results. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result. If the shape of the conductor is other than circular (i.e., angle, channel, H-beam), an analysis of the magnetic field is required to use an LCD, especially at low current levels.

  14. Kinesio Taping effects on knee extension force among soccer players

    PubMed Central

    Serra, Maysa V. G. B.; Vieira, Edgar R.; Brunt, Denis; Goethel, Márcio F.; Gonçalves, Mauro; Quemelo, Paulo R. V.

    2015-01-01

    Background: Kinesio Taping (KT) is widely used, however the effects of KT on muscle activation and force are contradictory. Objective: To evaluate the effects of KT on knee extension force in soccer players. Method: This is a clinical trial study design. Thirty-four subjects performed two maximal isometric voluntary contractions of the lower limbs pre, immediately post, and 24 hours after tape application on the lower limbs. Both lower limbs were taped, using K-Tape and 3M Micropore tape randomly on the right and left thighs of the participants. Isometric knee extension force was measured for dominant side using a strain gauge. The following variables were assessed: peak force, time to peak force, rate of force development until peak force, time to peak rate of force development, and 200 ms pulse. Results: There were no statistically significant differences in the variables assessed between KT and Micropore conditions (F=0.645, p=0.666) or among testing sessions (pre, post, and 24h after) (F=0.528, p=0.868), and there was no statistical significance (F=0.271, p=0.986) for interaction between tape conditions and testing session. Conclusion: KT did not affect the force-related measures assessed immediately and 24 hours after the KT application compared with Micropore application, during maximal isometric voluntary knee extension. PMID:25789557

  15. The effect of Kinesio Taping on handgrip strength

    PubMed Central

    Lemos, Thiago Vilela; Pereira, Kelice Cristina; Protássio, Carina Celedonio; Lucas, Lorrane Barbosa; Matheus, Joao Paulo C.

    2015-01-01

    [Purpose] The purpose of this research was to evaluate the change in muscle function induced by a Kinesio Tape application with no or moderate tension, to the dominant and non-dominant arms. [Subjects and Methods] This research was a quantitative study, in which 75 women participated. The subjects, aged 18–30 years, were divided into 3 groups, Kinesio, Kinesio without Tension, and Control, and they were assessed before the taping intervention and after 30 minutes, 24 hours, and 48 hours of taping. [Results] The Kinesio group subjects demonstrated an increase in handgrip strength after 30 minutes, 24 hours, and 48 hours of tape application compared to control. A statistically significant increase in strength was observed in the Kinesio group comparison to the Control after 24 hours and 48 hours for the right hand, and after 48 hours for the left hand. Improvement in the Kinesio group compared to the Kinesio without Tension was observed only after 24 hours of taping application, and only in the right hand. [Conclusion] The Kinesio Taping method augmented the handgrip strength of healthy women, and the increase in grip strength was maintained for 48 hours after its application; the dominant hand demonstrated the greatest strength values. PMID:25931682

  16. The effect of Kinesio Taping on handgrip strength.

    PubMed

    Lemos, Thiago Vilela; Pereira, Kelice Cristina; Protássio, Carina Celedonio; Lucas, Lorrane Barbosa; Matheus, Joao Paulo C

    2015-03-01

    [Purpose] The purpose of this research was to evaluate the change in muscle function induced by a Kinesio Tape application with no or moderate tension, to the dominant and non-dominant arms. [Subjects and Methods] This research was a quantitative study, in which 75 women participated. The subjects, aged 18-30 years, were divided into 3 groups, Kinesio, Kinesio without Tension, and Control, and they were assessed before the taping intervention and after 30 minutes, 24 hours, and 48 hours of taping. [Results] The Kinesio group subjects demonstrated an increase in handgrip strength after 30 minutes, 24 hours, and 48 hours of tape application compared to control. A statistically significant increase in strength was observed in the Kinesio group comparison to the Control after 24 hours and 48 hours for the right hand, and after 48 hours for the left hand. Improvement in the Kinesio group compared to the Kinesio without Tension was observed only after 24 hours of taping application, and only in the right hand. [Conclusion] The Kinesio Taping method augmented the handgrip strength of healthy women, and the increase in grip strength was maintained for 48 hours after its application; the dominant hand demonstrated the greatest strength values.

  17. Development of the industrial scale Ag/Bi-2223 tape

    NASA Astrophysics Data System (ADS)

    Fujikami, J.; Kaneko, T.; Ayai, N.; Kobayashi, S.; Hayashi, K.; Takei, H.; Sato, K.

    2002-10-01

    Tape shaped silver-sheathed Bi-2223 superconducting wire (Bi-2223 tape) technologies are reported. The operations of superconducting apparatus at liquid nitrogen temperature or at 20-30 K are expectable by using Bi-2223-tapes. The reduction of AC loss at 77 K is critical for power cable application, such as electric transmission cable and transformer prototypes. Thinning of the tape thickness and twisting of the tapes are the main techniques for the reduction of AC loss. For the power transformer application, coating technology is investigated to have good electrical insulation. The refrigerator-cooled magnet for industrial use is another example of the superconducting apparatus operating at 20-30 K. It is important to know the critical current density dependence on the applied magnetic field ( Jc- B dependence) for the magnet design. It was confirmed that Jc of the Bi-2223 tape, which shows Jc=30 kA/cm 2 at 77 K in self-magnetic field, exceeds 100 kA/cm 2 at 20 K, and 1 T.

  18. Longitudinal magnetization loss in twisted multifilamentary Bi2223 tape

    NASA Astrophysics Data System (ADS)

    Amemiya, N.; Rabbers, J.-J.; Krooshoop, B. E.; ten Haken, B.; ten Kate, H.; Ayai, N.; Hayashi, K.

    2002-08-01

    Multifilamentary Bi2223 tapes are exposed to the longitudinal magnetic field as well as the transverse one in some electrical power apparatuses such as multilayer power transmission cables. Here, we define the longitudinal and transverse magnetic fields as the field components parallel and perpendicular to the tape axis, respectively. If the filament-bundle is twisted, it can couple to the AC longitudinal magnetic field to generate the longitudinal magnetization loss. Furthermore, the AC transport current flowing spirally in the twisted filament-bundle possibly influences the longitudinal magnetization. The longitudinal magnetization loss was measured in a twisted multifilamentary Bi2223 tape exposed to longitudinal magnetic field and carrying the transport current. The measured longitudinal magnetization loss in the twisted tape exposed to the longitudinal magnetic field is larger than that in another untwisted tape. Supplying the AC transport current changes the longitudinal magnetization loss in the twisted tape exposed to the AC longitudinal magnetic field. The influence of the transport current depends on the phase relation between the longitudinal magnetic field and the transport current. If their phase difference is 0°, the longitudinal magnetization loss decreases remarkably with increasing amplitude of the transport current. It means that the change in the current distribution due to the transport current results in the decrease in the power flow from the magnet power supply. But, a preliminary measurement of the transport loss shows that the total loss increases with increasing transport current.

  19. Tape blisters after hip surgery: can they be eliminated completely?

    PubMed

    Koval, Kenneth J; Egol, Kenneth A; Hiebert, Rudi; Spratt, Kevin F

    2007-05-01

    It was recently reported that use of a perforated, stretchable cloth tape instead of silk tape reduced the incidenc of postoperative blisters around the hip from 41% to 10%. The present prospective randomized study was conducted to determine whether use of spica bandage (vs the cloth tape) could further reduce or eliminate the incidence of these blisters. Patients were randomized to 2 treatmen groups: perforated, stretchable cloth tape (Hypafix; Smit & Nephew, Memphis, Tenn) and elastic spica bandage tha was started at the lower thigh and was extended aroun the hip and abdomen. After surgery, cloth tape or spic bandage was applied over the postoperative dressing, with care taken not to produce skin tension. At the first dressing change, presence or absence of blisters was recorded, along with their number, size, location, and type. All subsequent dressing changes were done much as they wer at surgery, using the assigned type of dressing. Presence or absence of blisters was recorded at each subsequent dressing change. Two hundred ninety-four patients (300 hips) were enrolled. Twenty-two (7.33%) of the 300 hips developed a blister. Risk for developing a blister was 10% with the cloth tape versus 4.67% with the elastic spica bandage (P < .09). Surgery type (arthroplasty vs open reduction and internal fixation [ORIF], P < .03) and surgery duration (P < .05) had more of an effect on postoperative blister formation than dressing type.

  20. Staying sticky: contact self-cleaning of gecko-inspired adhesives

    PubMed Central

    Mengüç, Yiğit; Röhrig, Michael; Abusomwan, Uyiosa; Hölscher, Hendrik; Sitti, Metin

    2014-01-01

    The exceptionally adhesive foot of the gecko remains clean in dirty environments by shedding contaminants with each step. Synthetic gecko-inspired adhesives have achieved similar attachment strengths to the gecko on smooth surfaces, but the process of contact self-cleaning has yet to be effectively demonstrated. Here, we present the first gecko-inspired adhesive that has matched both the attachment strength and the contact self-cleaning performance of the gecko's foot on a smooth surface. Contact self-cleaning experiments were performed with three different sizes of mushroom-shaped elastomer microfibres and five different sizes of spherical silica contaminants. Using a load–drag–unload dry contact cleaning process similar to the loads acting on the gecko foot during locomotion, our fully contaminated synthetic gecko adhesives could recover lost adhesion at a rate comparable to that of the gecko. We observed that the relative size of contaminants to the characteristic size of the microfibres in the synthetic adhesive strongly determined how and to what degree the adhesive recovered from contamination. Our approximate model and experimental results show that the dominant mechanism of contact self-cleaning is particle rolling during the drag process. Embedding of particles between adjacent fibres was observed for particles with diameter smaller than the fibre tips, and further studied as a temporary cleaning mechanism. By incorporating contact self-cleaning capabilities, real-world applications of synthetic gecko adhesives, such as reusable tapes, clothing closures and medical adhesives, would become feasible. PMID:24554579

  1. Staying sticky: contact self-cleaning of gecko-inspired adhesives.

    PubMed

    Mengüç, Yigit; Röhrig, Michael; Abusomwan, Uyiosa; Hölscher, Hendrik; Sitti, Metin

    2014-05-06

    The exceptionally adhesive foot of the gecko remains clean in dirty environments by shedding contaminants with each step. Synthetic gecko-inspired adhesives have achieved similar attachment strengths to the gecko on smooth surfaces, but the process of contact self-cleaning has yet to be effectively demonstrated. Here, we present the first gecko-inspired adhesive that has matched both the attachment strength and the contact self-cleaning performance of the gecko's foot on a smooth surface. Contact self-cleaning experiments were performed with three different sizes of mushroom-shaped elastomer microfibres and five different sizes of spherical silica contaminants. Using a load-drag-unload dry contact cleaning process similar to the loads acting on the gecko foot during locomotion, our fully contaminated synthetic gecko adhesives could recover lost adhesion at a rate comparable to that of the gecko. We observed that the relative size of contaminants to the characteristic size of the microfibres in the synthetic adhesive strongly determined how and to what degree the adhesive recovered from contamination. Our approximate model and experimental results show that the dominant mechanism of contact self-cleaning is particle rolling during the drag process. Embedding of particles between adjacent fibres was observed for particles with diameter smaller than the fibre tips, and further studied as a temporary cleaning mechanism. By incorporating contact self-cleaning capabilities, real-world applications of synthetic gecko adhesives, such as reusable tapes, clothing closures and medical adhesives, would become feasible.

  2. Instant acting adhesive system

    NASA Technical Reports Server (NTRS)

    Davis, T. R.; Haines, R. C.

    1971-01-01

    Adhesive developes 80 percent of minimum bond strength of 250 psi less than 30 sec after activation is required. Adhesive is stable, handles easily, is a low toxic hazard, and is useful in industrial and domestic prototype bonding and clamping operations.

  3. Acetylene-terminated polyimide adhesives

    NASA Technical Reports Server (NTRS)

    Hanky, A. O.

    1983-01-01

    The nadic-encapped LARC-13 addition polyimide exhibits excellent flow, is easy to process, and can be utilized for short terms at temperatures up to 593 C. It retains good lap shear strength as an adhesive for titanium after aging in air up to 125 hours at 316 C; but lap shear strength degrades with longer exposures at that temperature. Thermid 600, an addition polyimide that is acetylene encapped, exhibits thermomechanical properties even after long term exposure in at air at 316 C. An inherent drawback of this system is that it has a narrow processing window. An acetylene encapped, addition polyimide which is a hybrid of these two systems was developed. It has good retention of strength after long term aging and is easily processed. The synthesis and characterization of various molecular weight oligomers of this system are discussed as well as the bonding, aging, and testing of lap shear adhesive samples.

  4. Niobium-germanium superconducting tapes for high-field magnet applications

    NASA Technical Reports Server (NTRS)

    Braginski, A. I.; Roland, G. W.; Daniel, M. R.; Woolam, J. A.

    1977-01-01

    A process of fabricating superconducting Nb3Ge tapes by chemical vapor deposition (CVD) has been developed and tapes up to 10 meters long fabricated. The typical properties achieved were: critical temperature T sub c = 20 K, upper critical field H sub c2 = 29 tesla at 4.2 K, and J sub c = 3 to 4 x 10 to the 8th power A m(-2) at 4.2 K, 18 tesla. The relative depression of T sub c and H sub c2 compared with the best thin film samples sputtered on sapphire was due to the presence of Nb5Ge3 second-phase particles used as flux pinning centers and to strains induced by thermal mixmatch with Hastelloy B tape substrates. A peculiar field dependence of flux pinning force that was observed in both CVD and sputtered Nb3Ge indicated a premature pin-breaking mechanism or a phase inhomogeneity. Directions of further optimization work were defined.

  5. Continuous YBa 2Cu 3O 7-tape deposition by thermal evaporation

    NASA Astrophysics Data System (ADS)

    Nemetschek, R.; Prusseit, W.; Holzapfel, B.; Eickemeyer, J.; DeBoer, B.; Miller, U.; Maher, E.

    2002-08-01

    Ni and Ni-alloy rolling assisted biaxially textured substrates provided both from IFW Dresden and an industrial partner (Plansee GmbH) were employed for the deposition of YBCO-coated conductors by thermal evaporation. The main advantages of this process are high volume deposition rates and relatively low substrate temperatures of 680 °C. As a consequence, a simple, economic, and very thin 100 nm CeO 2 buffer layer has turned out to be sufficient for high quality YBCO growth. For samples up to 20 cm long, critical current densities of 1.2 MA/cm 2 were achieved at 77 K and 2 μm thick films sustained transport currents beyond 150 A. Recently, the first continuously operating prototype tape deposition system based on thermal evaporation has been put into operation. A reel-to-reel tape winding mechanism is capable of handling YBCO and buffer layer deposition on tape 10 mm wide and up to 100 m long has been implemented. The YBCO-deposition speed of 4 m/h for a 1 μm layer.

  6. Variable tension control for discontinuous tape winding of composites based on constant extension ratio

    NASA Astrophysics Data System (ADS)

    Shi, Yaoyao; Yan, Long; He, Xiaodong

    2012-09-01

    Discontinuous tape winding, which has obvious advantages in large extension ratio winding, is widely used in the molding of composites. Therefore, the research on technological parameters becomes the focus of many scholars. However, how to accomplish the variable tension control is usually not fully considered. Accordingly, the constant extension ratio and the smoothness of winding process cannot be ensured. Aiming at the problem of tension control, this paper first gives a comparatively deep research on the control method and the interaction mechanism of tension, extension ratio, automatic lap and automatic rectification. Then, according to the winding process features, the mechanical device and the mathematical model of tension control system are established respectively. With regard to the characteristics of PID controller and fuzzy controller, the fuzzy self-tuning PID controller is designed. As a result, the variable tension control is realized during the winding and lapping process, and the constant extension ratio is guaranteed. Finally, a sample application is presented for demonstration. By presenting the variable tension control techniques for discontinuous tape winding, the constant extension ratio of tapes is achieved, the consecution and the automation degree of winding process is improved as well. Thus, the quality of wound products is guaranteed.

  7. LARC-13 adhesive development

    NASA Technical Reports Server (NTRS)

    Hill, S. G.; Sheppard, C. H.; Johnson, J. C.

    1980-01-01

    A LARC-13 type adhesive system was developed and property data obtained that demonstrated improved thermomechanical properties superior to base LARC-13 adhesive. An improved adhesive for 589 K (600 F) use was developed by physical or chemical modification of LARC-13. The adhesive was optimized for titanium and composite bonding, and a compatible surface preparation for titanium and composite substrates was identified. The data obtained with the improved adhesive system indicated it would meet the 589 K (600 F) properties desired for application on space shuttle components. Average titanium lap shear data were: (1) 21.1 MPa (3355 psi) at RT, (2) 13.0 MPa (1881 psi) at 600 F, and (3) 16.4 MPa (2335) after aging 125 hours at 600 F and tested at 600 F.

  8. Transparent layered YAG ceramics with structured Yb doping produced via tape casting

    NASA Astrophysics Data System (ADS)

    Hostaša, Jan; Piancastelli, Andreana; Toci, Guido; Vannini, Matteo; Biasini, Valentina

    2017-03-01

    The flexibility of the ceramic production process, in particular in terms of shaping and spatial control of distribution of active ions, is one of the strong points in favor of transparent ceramics. In high power lasers in particular, where thermal management is a critical issue, the finely controlled design of spatial distribution of the doping ions within the laser gain media can reduce undesired thermally induced effects and large temperature gradients, and thus enhance the efficiency and laser beam quality especially under increased thermal load. In the present work transparent structured YAG ceramics with Yb doping were produced by tape casting followed by thermal compression of assembled tapes and sintered under high vacuum. The thermal compression of variously doped tape cast layers is a very promising method because it allows a high precision and good control over dopant distribution in the sintered material. After sintering, the distribution of Yb across the layers was characterized by SEM-EDX and the thickness of Yb diffusion zones between the layers with different Yb content was measured. Optical homogeneity was assessed by means of optical transmittance mapping of the samples and by 2D scanning of laser output. The effect of structured dopant distribution on laser performance was measured in quasi-CW and CW regime with different duty factors. Slope efficiency values higher than 50% were measured both in quasi-CW and in CW lasing conditions. The results are in good agreement with previously calculated predictions, confirming the beneficial effect of structured doping on laser performances and enlightening the impact of the residual scattering losses. Compared to other processing methods, such as the pressing of granulated powders, tape casting followed by thermal compression leads to straight and narrow interfaces between layers with different composition and allows to build structures composed of extremely thin layers with defined dopant content.

  9. Influence of different operating conditions on irrigation uniformity with microperforated tapes

    NASA Astrophysics Data System (ADS)

    Moreno Pizani, María Alejandra; Jesús Farías Ramírez, Asdrúbal

    2013-04-01

    Irrigated agriculture is a safe alternative to meet the growing demand for food. Numerous studies show that proper management of localized irrigation can increase crop yields and reduce soil salinization. Therefore, periodic field systems irrigation assessments are needed in order to optimize the use efficiency of irrigation water, as well as, to increase the agricultural area covered by the same amount of water and to reduce the environmental impact. It was assessed the behavior of micro perforated tapes under different operating conditions, crops and regions of Venezuela. Evaluations were made on irrigated areas using Santeno ® Type I tape with the following crops: Banana (Musa sp), lettuce (Lactuca sativa L.), carrot (Daucus carota L) and forage sugar cane (Saccharum officinarum). In the other hand, Santeno ® Type II tape was used with papaya (Carica papaya L.) and melon (Cucumis melo L.) crops (the last crop using inverted irrigation tape). The procedures used for sampling and determining the uniformity indices of the system were performed using a series of adjustments to the methodology proposed by Keller and Karmeli (1975), Deniculi (1980) and De Santa and De Juan (1993), in order to increase the number of observations as a function of irrigation time. The calculated irrigation uniformity indices were as follow: Distribution Coefficient (UD), Uniformity Coefficient (CUC), Coefficient of Variation of Flows (CV) and Statistical Uniformity Coefficient (Us). The indices characterization was made according to Merrian and Keller (1978); Bralts (1986); Pizarro (1990) y ASAE (1996), respectively. The results showed that the irrigation uniformity for the evaluated systems varied from excellent to unacceptable, mainly due to the lack of maintenance and the absent of manometric connectors. Among the findings, it is possible to highlight the need for technical support to farmers, both in the installation, management and maintenance of irrigation systems. In this sense

  10. Characterization of the morphology of co-extruded, thermoplastic/rubber multi-layer tapes.

    PubMed

    l'Abee, R M A; Vissers, A M J T; Goossens, J G P; Spoelstra, A B; van Duin, M

    2009-11-03

    Tapes with alternating semi-crystalline thermoplastic/rubber layers with thicknesses varying from 100 nm up to several microm were prepared by multi-layer co-extrusion. The variation in layer thickness was obtained by varying the thermoplastic/rubber feed ratio. A systematic study on the use of various microscopy techniques to visualize the morphology of the layered systems is presented. The relatively large length scales and the sample preparation make optical microscopy (OM) unsuitable to study the morphology of the multi-layer tapes. Although excellent contrast between the thermoplastic and rubber layers can be obtained, the usually applied, relatively large magnifications limit the use of transmission electron microscopy (TEM) and atomic force microscopy (AFM) to small sample areas. The large range of applicable magnifications makes scanning electron microscopy (SEM) the most suitable technique to study the morphology of the multi-layer tapes. The sample preparation for SEM with a secondary electron (SE) detector is often based on the removal of one of the components, which may induce changes in the morphology. SEM with a back-scattered electron (BSE) detector is a very convenient method to study the morphology over a wide range of length scales, where the contrast between the different layers can be enhanced by chemical staining. Finally, the nucleation behavior (homogeneous versus heterogeneous) of the semi-crystalline layers, as probed by differential scanning calorimetry (DSC), provides valuable information on the layered morphology. The use of relatively straightforward DSC measurements shows a clear advantage with respect to the discussed microscopy techniques, since no sample preparation is required and relatively large samples can be studied, which are more representative for the bulk.

  11. Obituary: Gerald Frederick Tape, 1915-2005

    NASA Astrophysics Data System (ADS)

    Hughes, Robert E.

    2007-12-01

    Gerald Frederick Tape, a distinguished science statesman and administrator, died on November 20, 2005. Jerry, as he was known to all, took on many diverse and important responsibilities throughout his life and dealt with them with quiet authority and grace. This was the hallmark of his life. The Board of Trustees of Associated Universities, Inc., which he served for many years, expressed this in its condolences, writing "Jerry personified integrity, thoroughness and dedication. His sensitivity for the views of others, his sincerity, his personal commitment, his calm approach and his unfailing good humor were all greatly admired and respected." Jerry was born in Ann Arbor, Michigan on May 29, 1915 but grew up in Milan, a nearby country farm community, and in Ypsilanti where his father was Principal of Michigan State Normal College, which later became Eastern Michigan University (EMU). It was there that he first became interested in physics. It was there also that he met and courted Josephine Waffen, who later would become his wife for more than sixty-six years and fill their lives with three loving sons, Walter, James, and Thomas. Upon graduation from EMU, Jerry was awarded a scholarship that took him to the University of Michigan where he earned a Ph.D. in Physics, researching the decay modes of the radioisotopes of iodine. In the Fall of 1939, during the waning days of the Great Depression, he was offered an Instructorship in the Physics Department of Cornell University, a promising start for a fruitful academic career. He brought his bride Jo to Ithaca and joined the cyclotron group under Robert Bacher and Willy Higginbotham while devising a laboratory course in nuclear techniques for graduate students. Bacher and Higginbotham soon left Cornell to join a new wartime laboratory at the Massachusetts Institute of Technology (MIT) and many other colleagues were "drafted" for war work. Bacher persuaded Jerry to join him at the MIT Radiation Laboratory in February

  12. The use of McConnell taping to correct abnormal biomechanics and muscle activation patterns in subjects with anterior knee pain: a systematic review

    PubMed Central

    Leibbrandt, Dominique C; Louw, Quinette A

    2015-01-01

    [Purpose] The aim of this review was to present the available evidence for the effect of McConnell taping on knee biomechanics in individuals with anterior knee pain. [Methods] The PubMed, Medline, Cinahl, SPORTDiscus, PEDro and ScienceDirect electronic databases were searched from inception until September 2014. Experimental research on knee biomechanical or EMG outcomes of McConnell taping compared with no tape or placebo tape were included. Two reviewers completed the searches, selected the full text articles, and assessed the risk of bias of eligible studies. Authors were contacted for missing data. [Results] Eight heterogeneous studies with a total sample of 220 were included in this review. All of the studies had a moderate to low risk of bias. Pooling of data was possible for three outcomes: average knee extensor moment, average VMO/VL ratio and average VMO-VL onset timing. None of these outcomes revealed significant differences. [Conclusion] The evidence is currently insufficient to justify routine use of the McConnell taping technique in the treatment of anterior knee pain. There is a need for more evidence on the aetiological pathways of anterior knee pain, level one evidence, and studies investigating other potential mechanisms of McConnell taping. PMID:26311990

  13. Kinesio Tape and Shoulder-Joint Position Sense

    PubMed Central

    Aarseth, Lindsay M.; Suprak, David N.; Chalmers, Gordon R.; Lyon, Lonnie; Dahlquist, Dylan T.

    2015-01-01

    Context Joint position sense (JPS) is a key neuromuscular factor for developing and maintaining control of muscles around a joint. It is important when performing specialized tasks, especially at the shoulder. No researchers have studied how Kinesio Tape (KT) application affects JPS. Objective To investigate the effects of KT application and no tape on shoulder JPS at increasing shoulder elevations in athletes. Design Cross-sectional study. Setting University laboratory. Patients or Other Participants A total of 27 healthy athletes who did not participate in overhead sports (age = 20.44 ± 1.05 years, height = 175.02 ± 11.67 cm, mass = 70.74 ± 9.65 kg) with no previous pathologic shoulder conditions volunteered for the study. All participants were from 1 university. Intervention(s) Shoulder JPS was assessed at increasing elevations with and without KT application. Participants attempted to actively replicate 3 target positions with and without the KT and without visual guidance. Main Outcome Measure(s) We examined absolute and variable repositioning errors at increasing shoulder-elevation levels with and without KT application. Results Data revealed an interaction between tape and position for absolute error (F2,52 = 4.07, P = .02); simple effects revealed an increase in error, with KT demonstrating a 2.65° increase in error at 90° of elevation compared with no tape (t26 = 2.65, P = .01). The effect size was medium (ω2 = .135). Variable error showed no interaction of tape and position (F2,52 = .709, P = .50). Further analysis of simple effects was not needed. However, we still calculated the effect size and observed small effect sizes for tape (ω2 = .002), position (ω2 = .072), and tape by position (ω2 = .027). Conclusions At 90° of elevation, shoulder JPS was impaired by the application of KT. PMID:26090707

  14. Cyanoacrylate Adhesives in Eye Wounds.

    DTIC Science & Technology

    EYE, *WOUNDS AND INJURIES), (*ADHESIVES, EYE), (*ACRYLIC RESINS, ADHESIVES), CORNEA , HEALING, TISSUES(BIOLOGY), TOLERANCES(PHYSIOLOGY), NECROSIS, SURGICAL SUPPLIES, STRENGTH(PHYSIOLOGY), SURGERY, THERAPY

  15. Thermal and tensile strength testing of thermally-conductive adhesives and carbon foam

    NASA Astrophysics Data System (ADS)

    Chertok, M.; Fu, M.; Irving, M.; Neher, C.; Shi, M.; Tolfa, K.; Tripathi, M.; Vinson, Y.; Wang, R.; Zheng, G.

    2017-01-01

    Future collider detectors, including silicon tracking detectors planned for the High Luminosity LHC, will require components and mechanical structures providing unprecedented strength-to-mass ratios, thermal conductivity, and radiation tolerance. This paper studies carbon foam used in conjunction with thermally conductive epoxy and thermally conductive tape for such applications. Thermal performance and tensile strength measurements of aluminum-carbon foam-adhesive stacks are reported, along with initial radiation damage test results.

  16. Cytotoxicity of denture adhesives.

    PubMed

    de Gomes, Pedro Sousa; Figueiral, Maria Helena; Fernandes, Maria Helena R; Scully, Crispian

    2011-12-01

    Ten commercially available denture adhesives, nine soluble formulations (six creams, three powders) and one insoluble product (pad), were analyzed regarding the cytotoxicity profile in direct and indirect assays using L929 fibroblast cells. In the direct assay, fibroblasts were seeded over the surface of a thick adhesive gel (5%, creams; 2.5%, powders and pad). In the indirect assay, cells were cultured in the presence of adhesive extracts prepared in static and dynamic conditions (0.5-2%, creams; 0.25-1%, powders and pad). Cell toxicity was assessed for cell viability/proliferation (MTT assay) and cell morphology (observation of the F-actin cytoskeleton organization by confocal laser scanning microscopy). Direct contact of the L929 fibroblasts with the thick adhesive gels caused no, or only a slight, decrease in cell viability/proliferation. The adhesive extracts (especially those prepared in dynamic conditions) caused significantly higher growth inhibition of fibroblasts and, in addition, caused dose- and time-dependent effects, throughout the 6-72 h exposure time. Also, dose-dependent effects on cell morphology, with evident disruption of the F-actin cytoskeleton organization, were seen in the presence of most adhesives. In conclusion, the adhesives possessed different degrees of cytotoxicity, but similar dose- and time-dependent biological profiles.

  17. Evaluation of adhesive materials used on the Long Duration Exposure Facility

    NASA Technical Reports Server (NTRS)

    Dursch, H. W.; Keough, B. K.; Pippin, H. G.

    1995-01-01

    The adhesive and adhesive-like materials flown on LDEF included epoxies and silicones (including lap shear specimens), conformal coatings, potting compounds, and several tapes and transfer films. With the exception of the lap shear specimens, these materials were used in the fabrication and assembly of the experiments such as bonding thermal control surfaces to other hardware and holding individual specimens in place, similar to applications on other spacecraft. Typically, the adhesives were not exposed to solar radiation or atomic oxygen. Only one adhesive system was used in a structural application. This report documents all results of the Materials and Systems SIG investigation into the effect of long term low Earth orbit (LEO) exposure of these materials. Results of this investigation show that if the material was shielded from exposure to LDEF's external environment, the 69 month exposure to LEO had, in most cases, minimal effect on the material.

  18. Adhesive and Elastic Properties of DOPA-Containing Hydrogels

    NASA Astrophysics Data System (ADS)

    Webber, Rebecca; Shull, Ken; Messersmith, Phillip; Madhav, Priti

    2001-03-01

    It was recently determined that L-3,4-dihydroxyphenylalanine (DOPA) is primarily responsible for both the adhesion and crosslinking that occurs in mussel adhesive proteins (MAPs). In wet environments, MAPs form strong adhesive bonds to a large variety of substrates, making DOPA-modified polymers very interesting for adhesion studies. Polymer materials modified from or modeled after DOPA have large potential as biomedical adhesives and as adhesives in aqueous environments. The mechanical and adhesive properties of a DOPA-containing hydrogel were tested using an axisymmetric adhesion test modified from the method of Johnson, Kendall and Roberts. In accordance with this technique, a rigid, hemispherical indenter was brought into contact with hydrogel samples, generating load and displacement data. In addition, images were taken of the contact between the sample and indenter. Using the collected data and images, the adhesive properties of the material were calculated. Separate experiments were conducted in conditions of varying humidity and aqueous environments in order to determine any changes in the adhesive behavior of the hydrogel. Data resulting from experiments in each type of environment will be presented.

  19. Atomic scale enhancement of the adhesion of beryllium films to carbon substrates

    SciTech Connect

    Musket, R.G.; Wirtenson, G.R.

    1995-12-01

    We have used 200 keV carbon ions to enhance the adhesion of 240-nm thick Be films to polished, vitreous carbon substrates. Adhesion of the as-deposited films was below that necessary to pass the scotch-tape test. Carbon ion fluences less than 1.6x10{sup 14} C/cm{sup 2} were sufficient to ensure the passage of the tape test without affecting the optical properties of the films. Adhesion failure of the as-deposited film was attributed to an inner oxide layer between the Be and the carbon. Because this oxide ({approximately}5 nm of BeO) was not measurably changed by the irradiation process, these results are consistent with adhesion enhancement occurring on the atomic scale at the interface between the inner oxide and the carbon substrate. This conclusion was supported by Rutherford backscattering (RBS) data, and potential adhesion mechanisms are discussed with consideration of relative contributions from electronic and nuclear stopping.

  20. The NT digital micro tape recorder

    NASA Technical Reports Server (NTRS)

    Sasaki, Toshikazu; Alstad, John; Younker, Mike

    1993-01-01

    The description of an audio recorder may at first glance seem out of place in a conference which has been dedicated to the discussion of the technology and requirements of mass data storage. However, there are several advanced features of the NT system which will be of interest to the mass storage technologist. Moreover, there are a sufficient number of data storage formats in current use which have evolved from their audio counterparts to recommend a close attention to major innovative introductions of audio storage formats. While the existing analog micro-cassette recorder has been (and will continue to be) adequate for various uses, there are significant benefits to be gained through the application of digital technology. The elimination of background tape hiss and the availability of two relatively wide band channels (for stereo recording), for example, would greatly enhance listenability and speech intelligibility. And with the use of advanced high-density recording and LSI circuit technologies, a digital micro recorder can realize unprecedented compactness with excellent energy efficiency. This is what was accomplished with the NT-1 Digital Micro Recorder. Its remarkably compact size contributes to its portability. The high-density NT format enables up to two hours of low-noise digital stereo recording on a cassette the size of a postage stamp. Its highly energy-efficient mechanical and electrical design results in low power consumption; the unit can be operated up to 7 hours (for continuous recording) on a single AA alkaline battery. Advanced user conveniences include a multifunction LCD readout. The unit's compactness and energy-efficiency, in particular, are attributes that cannot be matched by existing analog and digital audio formats. The size, performance, and features of the NT format are of benefit primarily to those who desire improved portability and audio quality in a personal memo product. The NT Recorder is the result of over ten years of

  1. Focal adhesions in osteoneogenesis

    PubMed Central

    Biggs, M.J.P; Dalby, M.J

    2010-01-01

    As materials technology and the field of tissue engineering advances, the role of cellular adhesive mechanisms, in particular the interactions with implantable devices, becomes more relevant in both research and clinical practice. A key tenet of medical device technology is to use the exquisite ability of biological systems to respond to the material surface or chemical stimuli in order to help develop next-generation biomaterials. The focus of this review is on recent studies and developments concerning focal adhesion formation in osteoneogenesis, with an emphasis on the influence of synthetic constructs on integrin mediated cellular adhesion and function. PMID:21287830

  2. [Endothelial cell adhesion molecules].

    PubMed

    Ivanov, A N; Norkin, I A; Puchin'ian, D M; Shirokov, V Iu; Zhdanova, O Iu

    2014-01-01

    The review presents current data concerning the functional role of endothelial cell adhesion molecules belonging to different structural families: integrins, selectins, cadherins, and the immunoglobulin super-family. In this manuscript the regulatory mechanisms and factors of adhesion molecules expression and distribution on the surface of endothelial cells are discussed. The data presented reveal the importance of adhesion molecules in the regulation of structural and functional state of endothelial cells in normal conditions and in pathology. Particular attention is paid to the importance of these molecules in the processes of physiological and pathological angiogenesis, regulation of permeability of the endothelial barrier and cell transmigration.

  3. Adhesion of Polymer Vesicles

    NASA Astrophysics Data System (ADS)

    Lin, John J.; Bates, Frank S.; Hammer, Daniel A.; Silas, James A.

    2005-07-01

    The adhesion and bending modulus of polybutadiene-poly(ethylene oxide) block copolymer vesicles made from a bidisperse mixture of polymers is measured using micropipette aspiration. The adhesion energy between biotinylated vesicles and avidin beads is modeled by incorporating the extension of the adhesive ligands above the surface brush of the vesicle according to the blob model of bidisperse polymer mixtures of Komura and Safran assuming the polymer brush at the surface of the vesicle is compact. The same model accurately reproduces the scaling of the bending modulus with polymer composition.

  4. Adhesive Bonding for Shelters

    DTIC Science & Technology

    1980-12-01

    weru uvaluated, the type of etch bath " sweetener " and the type of rinse\\water used. The type of etch bath " sweetener " was found to have a dramatic effect...EA9601NW Adhesives on 50521134 Bare Adherenas 39 13 Stress-Durability Behavior Sun-mary 40 14 Effect of Ltch Bath Sweetening Alloy on Interracial Durability...34"’ -,,• , •’• •"• " ,,,,, 9 Adhesive/Primer/Adherend Alloy/Surface Preparation Combinations Adherend OFPL Sweetening Rinse Adhesive:Primer Alloy Alloy

  5. AC transport current losses of multifilamentary Bi(2223) tapes with varying filament geometries

    NASA Astrophysics Data System (ADS)

    Eckelmann, H.; Däumling, M.; Quilitz, M.; Goldacker, W.

    1998-02-01

    We have measured the ac transport current loss of eight different Bi(2223) tapes with varying filament geometries in the frequency range from 13 to 500 Hz at 77 K. The investigated tapes have an Ag sheath (i.e. 37 or 703 filaments) or a modified sheath using AgMg. Furthermore tapes with novel geometries such as multifilamentary wire-in-tube (WIT) tapes and jelly-roll tapes have been studied. In addition we have investigated twisted tapes with a twist-pitch of 1.4 cm in the 37 filamentary Ag and the 85 filamentary AgMg tapes. To compare these tapes with different Ic values we calculated the loss factors of the tapes. We find that all the loss factors lay within the limits given for an elliptical or a strip like conductor. Furthermore we find differences in the loss factors due to the filament geometries.

  6. The effective resistance between twisted superconducting filaments in tapes

    NASA Astrophysics Data System (ADS)

    Takács, S.; Iwakuma, M.; Funaki, K.

    2001-05-01

    We consider two mechanisms, which influence the effective resistance between crossing strands on flat cables or filaments in twisted tapes. The one-layer classical Rutherford-type cable and the tapes with twisted BSCCO filaments in silver matrix are taken as analogous cases. The amount of the matrix between strands or filaments increases the effective conductance compared with the direct current paths (determined by the touching area of the filaments). The increase factor is about two and can easily be suppressed by other effects, like the contact resistance between the superconductor and the matrix. The second mechanism is due to the existence of induced voltage between any points of crossing filaments. This leads to an additional effective conductance, proportional to the square of the total number of filaments. Both effects are not very important for isotropic superconductors, but due to the strong anisotropy of critical parameters they can dominate for high temperature superconductors. The first one may partially compensate the influence of the usually weaker critical current density perpendicular to the tape. The contribution due to the second effect can explain the higher resistivity of the matrix in BSCCO tapes compared with pure silver. It seems that to obtain low AC coupling losses in BSCCO tapes, structures with small filament number are required.

  7. Application of Kinesio Taping method for newborn swallowing difficultly

    PubMed Central

    Lin, Chien-Lin; Wu, Wei-Ting; Chang, Ke-Vin; Lin, Hong-Yi; Chou, Li-Wei

    2016-01-01

    Abstract Background: Preterm infants are at an increased risk of sucking problems, swallowing difficulty, and poor nourishment. During the neonatal period, the neurobehavioral organization of a preterm baby is poor compared with that of appropriate gestational age infants. Kinesio Taping has been widely used for edema control, joint protection, and proprioception training. With the help of augmentation of the sensory input for muscle facilitation and inhibition through tapping, the coordination of the target muscle groups can be improved. Until now, no research is available on the use of Kinesio Taping for the swallowing difficulty of infant. Methods: We reported a preterm infant suffering from brain edema at birth and swallowing difficultly until 40 weeks. The swallowing reflex was delayed. Moreover, lip closure and rooting reflex combined with the dysfunction grade of jaw movement were poor. We performed KT methods on the baby under the theory of the direction of the tape for facilitate or inhibit the muscle. Result: After the Kinesio Taping treatment, the sucking function was improved with good lip closure.One week later, the baby was discharged without the use of an oral gastric tube. Conclusion: Kinesio Taping contributed significantly to the improvement of impaired sucking and swallowing and could be implemented as a regular rehabilitative approach for infants suffering from these difficulties. PMID:27495080

  8. Induction Bonding of Prepreg Tape and Titanium Foil

    NASA Technical Reports Server (NTRS)

    Messier, Bernadette C.; Hinkley, Jeffrey A.; Johnston, Norman J.

    1998-01-01

    Hybrid structural laminates made of titanium foil and carbon fiber reinforced polymer composite offer a potential for improved performance in aircraft structural applications. To obtain information needed for the automated fabrication of hybrid laminates, a series of bench scale tests were conducted of the magnetic induction bonding of titanium foil and thermoplastic prepreg tape. Foil and prepreg specimens were placed in the gap of a toroid magnet mounted in a bench press. Several magnet power supplies were used to study power at levels from 0.5 to 1.75 kW and frequencies from 50 to 120 kHz. Sol-gel surface-treated titanium foil, 0.0125 cm thick, and PIXA/IM7 prepreg tape were used in several lay-up configurations. Data were obtained on wedge peel bond strength, heating rate, and temperature ramp over a range of magnet power levels and frequencies at different "power-on" times for several magnet gap dimensions. These data will be utilized in assessing the potential for automated processing. Peel strengths of foil-tape bonds depended on the maximum temperature reached during heating and on the applied pressure. Maximum peel strengths were achieved at 1.25kW and 8OkHz. Induction heating of the foil appears to be capable of good bonding up to 10 plies of tape. Heat transfer calculations indicate that a 20-40 C temperature difference exists across the tape thickness during heat-up.

  9. Combinatorial study of ceramic tape-casting slurries.

    PubMed

    Liu, Zhifu; Wang, Yiling; Li, Yongxiang

    2012-03-12

    Ceramic tape-casting slurries are complex systems composed of ceramic powder, solvent, and a number of organic components. Conventionally, the development of ceramic tape-casting slurries is time-consuming and of low efficiency. In this work, combinatorial approaches were applied to screen the ethanol and ethyl-acetate binary solvent based slurry for ceramic green tape-casting. The combinatorial libraries were designed considering the variation of the amount of PVB (Poly vinyl-butyral) binder, polyethylene-400, and butyl-benzyl-phthalate plasticizers, and glyceryl triacetate dispersant. A parallel magnetic stirring process was used to make the combinatorial slurry library. The properties mapping of the slurry library was obtained by investigating the sedimentation and rheological characteristics of the slurries. The slurry composition was refined by scaling up the experiments and comparing the microstructure, mechanical property, and sintering behavior of green tapes made from the selected slurries. Finally, a kind of ethanol-ethyl acetate binary solvent based slurry system suitable for making X7R dielectric ceramic green tapes was achieved.

  10. Raman Imaging of Dental Adhesive Diffusion

    NASA Astrophysics Data System (ADS)

    Wieliczka, D. M.; Kruger, M. B.; Spencer, P.

    1997-03-01

    In this project the dentin/adhesive interface was studied using micro-Raman spectroscopy in conjunction with laser light that is optimized to minimize the sample fluorescence. The commercial dentin adhesives Scotchbond Multi-Purpose Plus(3M) and Superbond (Sun Medical) were placed on coronal dentin substrates that were cut from extracted, unerupted third molars. The Raman spectra were obtained using a Dilor spectrometer with a resolution of 4 cm-1 over the spectral range of 100 to 2000 cm-1. All data were obtained using a Kr+ laser operating at 647 nm, a microscope with a 100x objective and with the sample mounted on a precision linear stage allowing for 0.5 (m positioning. Data were obtained from successive positions on the sample providing a spectral record of the interface from the pure adhesive to the pure dentin. Adhesive penetration into the dentin was determined by comparing the relative intensities of spectral bands attributable to the dentin versus the adhesive.

  11. The Effect of Skin Debris on Gunshot Residue Sampling and Detection.

    PubMed

    Burnett, Bryan R

    2016-11-01

    These experiments were designed to determine whether skin debris (desquamated epithelial cells and apparent skin oils) affects gunshot residue (GSR) particle detection on the sticky tape lift samples prepared for scanning electron microscopy (SEM). A dabbing experiment showed that GSR particles accumulate not only on the adhesive surface of the sampler, but also on the epithelial cell surfaces. Samplers were loaded with target GSR followed by dabbing 30 times on the back of a hand. Backscatter electron images were taken at 20 kV and for some at 30 kV of the same areas. The samplers were then treated with a sodium/calcium hypochlorite solution (bleach) to remove skin debris and again imaged in the SEM. Comparison of these images shows more GSR particles will likely be revealed at 30 kV than 20 kV and more particles revealed by the bleach treatment in an automated SEM system.

  12. Adhesives for Aerospace

    NASA Technical Reports Server (NTRS)

    Meade, L. E.

    1985-01-01

    The industry is hereby challenged to integrate adhesive technology with the total structure requirements in light of today's drive into automation/mechanization. The state of the art of adhesive technology is fairly well meeting the needs of the structural designers, the processing engineer, and the inspector, each on an individual basis. The total integration of these needs into the factory of the future is the next collective hurdle to be achieved. Improved processing parameters to fit the needs of automation/mechanization will necessitate some changes in the adhesive forms, formulations, and chemistries. Adhesives have, for the most part, kept up with the needs of the aerospace industry, normally leading the rest of the industry in developments. The wants of the aerospace industry still present a challenge to encompass all elements, achieving a totally integrated joined and sealed structural system. Better toughness with hot-wet strength improvements is desired. Lower cure temperatures, longer out times, and improved corrosion inhibition are desired.

  13. Optical adhesive property study

    SciTech Connect

    Sundvold, P.D.

    1996-01-01

    Tests were performed to characterize the mechanical and thermal properties of selected optical adhesives to identify the most likely candidate which could survive the operating environment of the Direct Optical Initiation (DOI) program. The DOI system consists of a high power laser and an optical module used to split the beam into a number of channels to initiate the system. The DOI requirements are for a high shock environment which current military optical systems do not operate. Five candidate adhesives were selected and evaluated using standardized test methods to determine the adhesives` physical properties. EC2216, manufactured by 3M, was selected as the baseline candidate adhesive based on the test results of the physical properties.

  14. Adhesion of Lunar Dust

    NASA Technical Reports Server (NTRS)

    Walton, Otis R.

    2007-01-01

    This paper reviews the physical characteristics of lunar dust and the effects of various fundamental forces acting on dust particles on surfaces in a lunar environment. There are transport forces and adhesion forces after contact. Mechanical forces (i.e., from rover wheels, astronaut boots and rocket engine blast) and static electric effects (from UV photo-ionization and/or tribo-electric charging) are likely to be the major contributors to the transport of dust particles. If fine regolith particles are deposited on a surface, then surface energy-related (e.g., van der Walls) adhesion forces and static-electric-image forces are likely to be the strongest contributors to adhesion. Some measurement techniques are offered to quantify the strength of adhesion forces. And finally some dust removal techniques are discussed.

  15. Strongly enhanced current densities in Sr0.6K0.4Fe2As2 + Sn superconducting tapes

    PubMed Central

    Lin, He; Yao, Chao; Zhang, Xianping; Zhang, Haitao; Wang, Dongliang; Zhang, Qianjun; Ma, Yanwei; Awaji, Satoshi; Watanabe, Kazuo

    2014-01-01

    Improving transport current has been the primary topic for practical application of superconducting wires and tapes. However, the porous nature of powder-in-tube (PIT) processed iron-based tapes is one of the important reasons for low critical current density (Jc) values. In this work, the superconducting core density of ex-situ Sr0.6K0.4Fe2As2 + Sn tapes, prepared from optimized precursors, was significantly improved by employing a simple hot pressing as an alternative route for final sintering. The resulting samples exhibited optimal critical temperature (Tc), sharp resistive transition, small resistivity and high Vickers hardness (Hv) value. Consequently, the transport Jc reached excellent values of 5.1 × 104 A/cm2 in 10 T and 4.3 × 104 A/cm2 in 14 T at 4.2 K, respectively. Our tapes also exhibited high upper critical field Hc2 and almost field-independent Jc. These results clearly demonstrate that PIT pnictide wire conductors are very promising for high-field magnet applications. PMID:24663054

  16. Removal of an eroded transobturator tape from the bladder using laser cystolithotripsy and cystoscopic resection.

    PubMed

    Feiner, Benny; Auslender, Ron; Mecz, Yoel; Lissak, Arie; Stein, Avi; Abramov, Yoram

    2009-03-01

    This case presentation describes a unique minimally invasive technique of treating transobturator tape erosion into the urinary bladder with calculus growth. A 42-year-old woman was admitted for recurrent urinary tract infections, 9 months after a transobturator tape procedure. Pelvic sonography, followed by cystourethroscopy, demonstrated an eroded tape in the bladder with heavy calculus growth and diffuse mucosal inflammation. The calculus was fragmented by using laser cystolithotripsy, and the tape was excised and removed by using cystoscopic resection. Intravesical tape erosion with calculus growth can complicate transobturator tape procedures, and is amenable to transurethral laser cystolithotripsy and cystoscopic resection.

  17. The ISEE-3 ULEWAT: Flux tape description and heavy ion fluxes 1978-1984. [plasma diagnostics

    NASA Technical Reports Server (NTRS)

    Mason, G. M.; Klecker, B.

    1985-01-01

    The ISEE ULEWAT FLUX tapes contain ULEWAT and ISEE pool tape data summarized over relatively long time intervals (1hr) in order to compact the data set into an easily usable size. (Roughly 3 years of data fit onto one 1600 BPI 9-track magnetic tape). In making the tapes, corrections were made to the ULEWAT basic data tapes in order to, remove rate spikes and account for changes in instrument response so that to a large extent instrument fluxes can be calculated easily from the FLUX tapes without further consideration of instrument performance.

  18. Epithelial adhesive junctions

    PubMed Central

    Capaldo, Christopher T.; Farkas, Attila E.

    2014-01-01

    Epithelial adhesive cell-to-cell contacts contain large, plasma membrane-spanning multiprotein aggregates that perform vital structural and signaling functions. Three prominent adhesive contacts are the tight junction, adherens junction, and the desmosome. Each junction type has unique cellular functions and a complex molecular composition. In this review, we comment on recent and exciting advances in our understanding of junction composition and function. PMID:24592313

  19. Critical Current Measurements in Commercial Tapes, Coils, and Magnets.

    NASA Astrophysics Data System (ADS)

    Gubser, D. U.; Soulen, R. J., Jr.; Fuller-Mora, W. W.; Francavilla, T. L.

    1996-03-01

    We have measured a number of tapes, coils, and magnets produced by commercial vendors and determined their properties as functions of magnetic field and temperature. The tapes were measured at the National High Magnetic Field Laboratory in magnetic fields to 20 tesla and at temperatures of 4.2 K, 27 K, 65 K, and 77 K. For the tapes we report critical currents and current-voltage characteristics. Six inch diameter coils were measured at NRL in zero magnetic field. Critical currents, current-voltage characteristics, and reliability studies are reported for the coils. Larger 10 inch diameter coils, which are to be used in a 200 hp superconducting motor, were also measured and results will be presented. The talk will also review the status of the most recent tests of the superconducting motor.

  20. Experimental Investigations of Woven Textile Tape as Strain Sensor

    NASA Astrophysics Data System (ADS)

    Kannaian, T.; Naveen, V. S.; Muthukumar, N.; Thilagavathi, G.

    2015-10-01

    In this article, a strain sensitive textile based elastomeric tape sensor has been developed and process parameters for sensor development are optimized. Polyester yarns are used as base threads and rubber threads are used as elastomer for the sensor development. The sensor has been developed with the help of narrow width tape loom by introducing the silver coated nylon yarn in the middle of the tape structure. The influence of weave structure, number of conductive threads and rubber thread tension on sensor development has been optimized by using the Box-Behnken method and the results are analyzed using the Design expert software. From the results, it is found that six numbers of conductive threads in a plain weave structure with rubber thread tension of 750 g is suitable for the sensor to give high gauge factor of 1.626.

  1. Cytotoxicity of Dental Adhesives In Vitro

    PubMed Central

    Koulaouzidou, Elisabeth A.; Helvatjoglu-Antoniades, Maria; Palaghias, George; Karanika-Kouma, Artemis; Antoniades, Dimitrios

    2009-01-01

    Objectives The purpose of this study was to evaluate the cytotoxic effect of six dental adhesives (Admira Bond, Clearfil Liner Bond 2V, ED Primer II, Fuji Bond LC, Gluma Comfort Bond, and NanoBond) applied to cell cultures. Methods The experiments were performed on two cell lines, rat pulp cells (RPC-C2A) and human lung fibroblasts (MRC5). Samples of the adhesives were light-cured and placed in culture medium for 24 hours. The extraction media was applied on the RPC-C2A and the MRC5 cells. Complete medium was used as a control. Cytotoxicity was evaluated with a modified sulforhodamine B (SRB) assay after 24 hours of exposure. Results The cell survival of RPC-C2A cells exposed to Fuji Bond LC, NanoBond, Clearfil Liner Bond 2V, ED Primer II, Admira Bond and Gluma Comfort Bond was 73%, 67%, 50%, 20%, 18% and 5% respectively, relative to the cell survival with the control medium. In the MRC5 cell line, the relative survival was 98%, 80%, 72%, 41%, 19% and 7% after exposure to NanoBond, Fuji Bond LC, Clearfil Liner Bond 2V, ED Primer II, Admira Bond and Gluma Comfort Bond, respectively. Conclusions Different types of dental adhesives showed different cytotoxic effects on cells in vitro. The self-etch adhesives were superior in terms of cytotoxicity. The different cytotoxic effects of dental adhesives should be considered when selecting an appropriate adhesive for operative restorations. PMID:19262725

  2. Mirror-touch and ticker tape experiences in synesthesia

    PubMed Central

    Chun, Charlotte A.; Hupé, Jean-Michel

    2013-01-01

    A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia's connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person's arm being stroked can evoke physical touch sensation on one's own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker's mouth. To explore synesthesia's associations with these phenomena, a diverse group (n = 3743) was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1017 eligible respondents, synesthetes (across all subtypes) reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However, effect sizes were small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2–4%) and sequence-space synesthesia (9–14%). Within synesthesia, grapheme-personification, also called ordinal-linguistic personification (OLP) was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect sizes. PMID

  3. Mirror-touch and ticker tape experiences in synesthesia.

    PubMed

    Chun, Charlotte A; Hupé, Jean-Michel

    2013-01-01

    A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia's connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person's arm being stroked can evoke physical touch sensation on one's own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker's mouth. To explore synesthesia's associations with these phenomena, a diverse group (n = 3743) was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1017 eligible respondents, synesthetes (across all subtypes) reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However, effect sizes were small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2-4%) and sequence-space synesthesia (9-14%). Within synesthesia, grapheme-personification, also called ordinal-linguistic personification (OLP) was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect sizes.

  4. Insert Coil Test for HEP High Field Magnets Using YBCO Coated Conductor Tapes

    SciTech Connect

    Lombardo, V.; Barzi, E.; Turrioni, D.; Zlobin, A.V.; /Fermilab

    2011-06-15

    The final beam cooling stages of a Muon Collider may require DC solenoid magnets with magnetic fields of 30-50 T. In this paper we present progress in insert coil development using commercially available YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} Coated Conductor. Technological aspects covered in the development, including coil geometry, insulation, manufacturing process and testing are summarized and discussed. Test results of double pancake coils operated in liquid nitrogen and liquid helium are presented and compared with the performance of YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} tape short samples.

  5. Gecko-Inspired, Controlled Adhesion and Its Applications

    NASA Astrophysics Data System (ADS)

    Menguc, Yigit

    might replace VelcroRTMand zippers in clothing, and might become a critical component in sports gear, e.g. soccer goal keeper and rock climber gloves. The reversible, controllable nature of the adhesion, as well as its incredible bonding strength, suggests more impressive possibilities for gecko-inspired adhesives: perhaps it might act as a fastener for temporary or emergency construction. We might yet see rolls of single-sided and double-sided gecko-tape sold in hardware stores, not as a replacement for duct tape, but as a replacement for nails, staples and screws. (Abstract shortened by UMI.)

  6. STS-97 Mission Highlights Resource Tape. Part 2

    NASA Technical Reports Server (NTRS)

    2001-01-01

    A continuation of 'STS-97 Mission Highlights Resource Tape, Part 1 of 3' (document ID 20010020281), the activities of flight days four through six are seen. Footage includes the spacewalks performed by Noriega and Tanner, the deployment of the Solar Array Blanket Box (SABB), various shots of Endeavour's payload bay and the International Space Station (ISS), and the deployment of the solar radiators on the ISS. Flight days seven through eleven and Endeavour's landing are shown in 'STS-97 Mission Highlights Resource Tape, Part 3 of 3' (document ID 20010020283).

  7. Improvement in performance of heat exchanger fitted with twisted tape

    SciTech Connect

    Sivashanmugam, P.; Sundaram, S.

    1999-04-01

    The improvement in performance of a double pipe heat exchanger fitted with twisted tape as a turbulence promoter with twist ratios of 15.649, 8.54, 5.882, 4.95, and 4.149 was experimentally studied. A maximum percentage gain of 44.7% in energy transfer rate was obtained for the twisted tape of twist ratio 4.149. For all twist ratios, the gain decreases with the Reynolds number and becomes constant for Reynolds numbers greater than 3,000. The smaller the twist ratio is, the larger the gain in energy for a specific Reynolds number.

  8. Overview of Challenger Space Shuttle tape-data recovery study

    NASA Astrophysics Data System (ADS)

    Bhushan, B.; Phelan, R. M.

    1987-09-01

    The Challenger Orbiter's magnetic flight recorder tapes underwent six weeks of deterioration in sea water, and could not be unwound without damage to the recording surface. Attention is presently given to the method used to chemically treat the damaged magnesium tape reels in a wash tank, under partial vacuum, with nitric acid and methanol. The treated reel was relubricated before careful unwinding at 0.15 m/min. Over 90 percent of the data blocks from a recorder were readable, and 100 percent of the voice data blocks were recovered.

  9. Visualizing and quantifying adhesive signals

    PubMed Central

    Sabouri-Ghomi, Mohsen; Wu, Yi; Hahn, Klaus; Danuser, Gaudenz

    2008-01-01

    Understanding the structural adaptation and signaling of adhesion sites in response to mechanical stimuli requires in situ characterization of the dynamic activation of a large number of adhesion components. Here, we review high resolution live cell imaging approaches to measure forces, assembly and interaction of adhesion components, and the activation of adhesion-mediated signals. We conclude by outlining computational multiplexing as a framework for the integration of these data into comprehensive models of adhesion signaling pathways. PMID:18586481

  10. Adhesive characterization in prestressed piezoelectric laminates

    NASA Astrophysics Data System (ADS)

    Hodges, Charles A.; Mossi, Karla M.; Scott, Lisa A.

    2003-08-01

    Pre-stressed piezoelectric laminates, consisting of one or more metal layers and a piezoelectric material bonded together with an adhesive, have been widely studied over the past few years, both numerically and experimentally. Most of the current research has concentrated on the effect of the metal layers, types and geometry, along with variations in the active layer of the laminate. Historically, the adhesive layer has been neglected as a contributing factor in the overall performance of the final device. This paper attempts to address the effect of the adhesive line thickness and its influence on the performance of pre-stressed piezoelectric laminates under specific boundary conditions. All laminates tested were constructed with the following lay-up: 0.354 mm thick stainless steel, adhesive, 0.381 mm PZT ceramic, adhesive, and a 0.0254 mm aluminum layer. The devices having an adhesive line thickness of 0.169 mm were classified as group A, and group B were the devices with an adhesive line thickness of 0.036 mm. The adhesive line thickness for group A was approximately 21% more than the line thickness of group B. The devices were tested in a simply supported, free-free condition under a series of loads at a constant frequency of 5 Hz over a voltage range from 400 to 800 Volts peak-to-peak. Displacement was measured using loads of 25, 50, 75, 100, and 200 grams for each actuator. The data from each group was averaged and compared. The results showed group B generated more displacement at the same "arm weight" applied as compared to group A. However, only three samples for group B were measured since the rest of the samples failed during testing. Failure of the devices of group B may be due to the ultimate stress of the devices and their ability to lift a load under those conditions. The study demonstrated that adhesive layer thickness, along with the manufacturing process, has to be taken into account when developing an application that requires load

  11. The chemistry of stalked barnacle adhesive (Lepas anatifera)

    PubMed Central

    Jonker, Jaimie-Leigh; Morrison, Liam; Lynch, Edward P.; Grunwald, Ingo; von Byern, Janek; Power, Anne Marie

    2015-01-01

    The results of the first chemical analysis of the adhesive of Lepas anatifera, a stalked barnacle, are presented. A variety of elements were identified in scanning electron microscopy with energy dispersive spectrometry (SEM-EDS) of the adhesive, including Na, Mg, Ca, Cl, S, Al, Si, K and Fe; however, protein–metal interactions were not detected in Raman spectra of the adhesive. Elemental signatures from SEM-EDS of L. anatifera adhesive glands were less varied. Phosphorous was mostly absent in adhesive samples; supporting previous studies showing that phosphoserines do not play a significant role in adult barnacle adhesion. Disulfide bridges arising from Cys dimers were also investigated; Raman analysis showed weak evidence for S–S bonds in L. anatifera. In addition, there was no calcium carbonate signal in the attenuated total reflectance Fourier transform infrared spectra of L. anatifera adhesive, unlike several previous studies in other barnacle species. Significant differences were observed between the Raman spectra of L. anatifera and Balanus crenatus; these and a range of Raman peaks in the L. anatifera adhesive are discussed. Polysaccharide was detected in L. anatifera adhesive but the significance of this awaits further experiments. The results demonstrate some of the diversity within barnacle species in the chemistry of their adhesives. PMID:25657841

  12. The chemistry of stalked barnacle adhesive (Lepas anatifera).

    PubMed

    Jonker, Jaimie-Leigh; Morrison, Liam; Lynch, Edward P; Grunwald, Ingo; von Byern, Janek; Power, Anne Marie

    2015-02-06

    The results of the first chemical analysis of the adhesive of Lepas anatifera, a stalked barnacle, are presented. A variety of elements were identified in scanning electron microscopy with energy dispersive spectrometry (SEM-EDS) of the adhesive, including Na, Mg, Ca, Cl, S, Al, Si, K and Fe; however, protein-metal interactions were not detected in Raman spectra of the adhesive. Elemental signatures from SEM-EDS of L. anatifera adhesive glands were less varied. Phosphorous was mostly absent in adhesive samples; supporting previous studies showing that phosphoserines do not play a significant role in adult barnacle adhesion. Disulfide bridges arising from Cys dimers were also investigated; Raman analysis showed weak evidence for S-S bonds in L. anatifera. In addition, there was no calcium carbonate signal in the attenuated total reflectance Fourier transform infrared spectra of L. anatifera adhesive, unlike several previous studies in other barnacle species. Significant differences were observed between the Raman spectra of L. anatifera and Balanus crenatus; these and a range of Raman peaks in the L. anatifera adhesive are discussed. Polysaccharide was detected in L. anatifera adhesive but the significance of this awaits further experiments. The results demonstrate some of the diversity within barnacle species in the chemistry of their adhesives.

  13. Improved critical current density in ex situ processed MgB2 tapes by the size reduction of grains and crystallites by high-energy ball milling

    NASA Astrophysics Data System (ADS)

    Fujii, Hiroki; Ishitoya, Akira; Itoh, Shinji; Ozawa, Kiyoshi; Kitaguchi, Hitoshi

    2017-03-01

    We have fabricated Fe-sheathed MgB2 tapes through an ex situ process in a powder-in-tube (PIT) technique using powders ball milled under various conditions. Although the ex situ processed wires and tapes using the high-energy ball milled MgB2 powders have been studied and the decrease of grain and crystallite sizes of MgB2 and the critical current density (Jc) improvement of those conductors were reported so far, the use of filling powders milled at a higher rotation speed than previously reported further decreases the crystallite size and improves the Jc properties. The improved Jc values at 4.2 K and 10 T were nearly twice as large as those previously reported. Those milled powders and hence as-rolled tapes easily receive contamination in air. Thus, the transport Jc properties are easily deteriorated and scattered unless the samples are handled with care. The optimized heat treatment temperature (Topt) of those tape samples at which best performance in the Jc property is obtained decreases by more than 100 °C, compared with that of tapes using the as-received MgB2 powder.

  14. Prevailing Torque Locking Feature in Threaded Fasteners Using Anaerobic Adhesive

    NASA Technical Reports Server (NTRS)

    Hernandez, Alan; Hess, Daniel P.

    2016-01-01

    This paper presents results from tests to assess the use of anaerobic adhesive for providing a prevailing torque locking feature in threaded fasteners. Test procedures are developed and tests are performed on three fastener materials, four anaerobic adhesives, and both unseated assembly conditions. Five to ten samples are tested for each combination. Tests for initial use, reuse without additional adhesive, and reuse with additional adhesive are performed for all samples. A 48-hour cure time was used for all initial use and reuse tests. Test data are presented as removal torque versus removal angle with the specification required prevailing torque range added for performance assessment. Percent specification pass rates for the all combinations of fastener material, adhesive, and assembly condition are tabulated and reveal use of anaerobic adhesive as a prevailing torque locking feature is viable. Although not every possible fastener material and anaerobic adhesive combination provides prevailing torque values within specification, any combination can be assessed using the test procedures presented. Reuse without additional anaerobic adhesive generally provides some prevailing torque, and in some cases within specification. Reuse with additional adhesive often provides comparable removal torque data as in initial use.

  15. Evaluation of D-1 tape and cassette characteristics: Moisture content of Sony and Ampex D-1 tapes when delivered

    NASA Astrophysics Data System (ADS)

    Ashton, Gary

    Commercial D-1 cassette tapes and their associated recorders were designed to operate in broadcast studios and record in accordance with the International Radio Consultative Committee (CCIR) 607 digital video standards. The D-1 recorder resulted in the Society of Motion Picture and Television Engineers (SMPTE) standards 224 to 228 and is the first digital video recorder to be standardized for the broadcast industry. The D-1 cassette and associated media are currently marketed for broadcast use. The recorder was redesigned for data applications and is in the early stages of being evaluated. The digital data formats used are specified in MIL-STD-2179 and the American National Standards Institute (ANSI) X3.175-190 standard. In early 1990, the National Media Laboratory (NML) was asked to study the effects of time, temperature, and relative humidity on commercial D-1 cassettes. The environmental range to be studied was the one selected for the Advanced Tactical Air Reconnaissance System (ATARS) program. Several discussions between NML personnel, ATARS representatives, recorder contractors, and other interested parties were held to decide upon the experimental plan to be implemented. Review meetings were held periodically during the course of the experiment. The experiments were designed to determine the dimensional stability of the media and cassette since this is one of the major limiting factors of helical recorders when the media or recorders are subjected to non-broadcasting environments. Measurements were also made to characterize each sample of cassettes to give preliminary information on which purchase specifications could be developed. The actual tests performed on the cassettes and media before and after aging fall into the general categories listed.

  16. Computed tomography analysis of wood-adhesive bonds

    NASA Astrophysics Data System (ADS)

    Modzel, Gunter Georg Rolf

    The importance of wood bonding increased in the last decades due to the increased usage of wood composites whose performance depends to a large extent on the adhesive penetration and subsequent bonding of the adherends. The presented research used XMT (x-ray microtomography) to perform a non-destructive, three-dimensional analysis of the adhesive bondline and wood-structure of Southern yellow pine, Douglas-fir and yellow-poplar samples. A phenol-formaldehyde adhesive was used. The sodium hydroxide catalyst was replaced with rubidium hydroxide during resin formulation. This was done to improve the image contrast. The reconstructions of the wood structure of Southern yellow pine showed tracheids, rays, fusiform rays, resin canals and pits. On the Douglas-fir sample tracheids, pits and rays were displayed clearly. The yellow-poplar images showed vessels, fibers, bordered pits, scalariform sieve plates and rays. The renderings of the adhesive-bondline of Southern yellow pine proved the dominant role of tracheids for the adhesive flow and showed rays as a secondary pathway of adhesive flow. The results revealed no adhesive flow occured through bordered pits, while simple pits permitted some adhesive flow through ray parenchyma. The results for Douglas-fir showed a similar result; the tracheids were the predominant path of adhesive penetration, while rays played a secondary role and no adhesive flow through the pit aperture was visible. The adhesive flow through the microstructure of yellow-poplar wood occured mainly through vessels and also through rays, but no adhesive flow through the pits was directly observed. The segmentation of the images in three phases: void space, cell wall substance and adhesive, enabled the calculation of the effective bondline thickness based on the adhesive, as well as the volumetric measurement of all three elements and their share on the sample volume. Subsequent experiments showed that the exposure of the Southern yellow pine and yellow

  17. How To Choose Audio and Video Tape and Cassettes That Best Fit Your Needs

    ERIC Educational Resources Information Center

    Smith, Judson

    1978-01-01

    An audiovisual consultant presents a guide to selecting suitable and cost effective tape and cassettes. He describes and illustrates physical properties of tapes and includes a list of manufacturers and suppliers. (MF)

  18. Platelet Adhesion under Flow

    PubMed Central

    Ruggeri, Zaverio M.

    2011-01-01

    Platelet adhesive mechanisms play a well-defined role in hemostasis and thrombosis, but evidence continues to emerge for a relevant contribution to other pathophysiological processes including inflammation, immune-mediated responses to microbial and viral pathogens, and cancer metastasis. Hemostasis and thrombosis are related aspects of the response to vascular injury, but the former protects from bleeding after trauma while the latter is a disease mechanism. In either situation, adhesive interactions mediated by specific membrane receptors support the initial attachment of single platelets to cellular and extracellular matrix constituents of the vessel wall and tissues. In the subsequent steps of thrombus growth and stabilization, adhesive interactions mediate platelet to platelet cohesion (aggregation) and anchoring to the fibrin clot. A key functional aspect of platelets is their ability to circulate in a quiescent state surveying the integrity of the inner vascular surface, coupled to a prompt reaction wherever alterations are detected. In many respects, therefore, platelet adhesion to vascular wall structures, to one another or to other blood cells are facets of the same fundamental biological process. The adaptation of platelet adhesive functions to the effects of blood flow is the main focus of this review. PMID:19191170

  19. Room Temperature Characteristics of Polymer-Based Low Ice Adhesion Surfaces

    PubMed Central

    He, Zhiwei; Vågenes, Elisabeth T.; Delabahan, Chrisrosemarie; He, Jianying; Zhang, Zhiliang

    2017-01-01

    Ice adhesion is mainly dictated by surface properties, and water wettability is frequently correlated with ice adhesion strength. However, these established correlations are limited to high ice adhesion and become invalid when the ice adhesion strength is low. Here we carried out an experimental study to explore the relationships between low ice adhesion strength and room temperature surface properties. A variety of room temperature properties of 22 polymer-based hydrophilic and hydrophobic samples consisting of both low and high ice adhesion surfaces were analysed. The properties investigated include water adhesion force, water wettability, roughness, elastic modulus and hardness. Our results show that low ice adhesion strength does not correlate well with water contact angle and its variants, surface roughness and hardness. Low elastic modulus does not guarantee low ice adhesion, however, surfaces with low ice adhesion always show low elastic modulus. Low ice adhesion (below 60 kPa) of tested surfaces may be determinative of small water adhesion force (from 180 to 270 μN). Therefore, measurement of water adhesion force may provide an effective strategy for screening anti-icing or icephobic surfaces, and surfaces within specific values of water adhesion force will possibly lead to a low ice adhesion. PMID:28169370

  20. Room Temperature Characteristics of Polymer-Based Low Ice Adhesion Surfaces.

    PubMed

    He, Zhiwei; Vågenes, Elisabeth T; Delabahan, Chrisrosemarie; He, Jianying; Zhang, Zhiliang

    2017-02-07

    Ice adhesion is mainly dictated by surface properties, and water wettability is frequently correlated with ice adhesion strength. However, these established correlations are limited to high ice adhesion and become invalid when the ice adhesion strength is low. Here we carried out an experimental study to explore the relationships between low ice adhesion strength and room temperature surface properties. A variety of room temperature properties of 22 polymer-based hydrophilic and hydrophobic samples consisting of both low and high ice adhesion surfaces were analysed. The properties investigated include water adhesion force, water wettability, roughness, elastic modulus and hardness. Our results show that low ice adhesion strength does not correlate well with water contact angle and its variants, surface roughness and hardness. Low elastic modulus does not guarantee low ice adhesion, however, surfaces with low ice adhesion always show low elastic modulus. Low ice adhesion (below 60 kPa) of tested surfaces may be determinative of small water adhesion force (from 180 to 270 μN). Therefore, measurement of water adhesion force may provide an effective strategy for screening anti-icing or icephobic surfaces, and surfaces within specific values of water adhesion force will possibly lead to a low ice adhesion.

  1. Room Temperature Characteristics of Polymer-Based Low Ice Adhesion Surfaces

    NASA Astrophysics Data System (ADS)

    He, Zhiwei; Vågenes, Elisabeth T.; Delabahan, Chrisrosemarie; He, Jianying; Zhang, Zhiliang

    2017-02-01

    Ice adhesion is mainly dictated by surface properties, and water wettability is frequently correlated with ice adhesion strength. However, these established correlations are limited to high ice adhesion and become invalid when the ice adhesion strength is low. Here we carried out an experimental study to explore the relationships between low ice adhesion strength and room temperature surface properties. A variety of room temperature properties of 22 polymer-based hydrophilic and hydrophobic samples consisting of both low and high ice adhesion surfaces were analysed. The properties investigated include water adhesion force, water wettability, roughness, elastic modulus and hardness. Our results show that low ice adhesion strength does not correlate well with water contact angle and its variants, surface roughness and hardness. Low elastic modulus does not guarantee low ice adhesion, however, surfaces with low ice adhesion always show low elastic modulus. Low ice adhesion (below 60 kPa) of tested surfaces may be determinative of small water adhesion force (from 180 to 270 μN). Therefore, measurement of water adhesion force may provide an effective strategy for screening anti-icing or icephobic surfaces, and surfaces within specific values of water adhesion force will possibly lead to a low ice adhesion.

  2. Harmonic distortion analyzer speeds setup of magnetic tape recorders

    NASA Technical Reports Server (NTRS)

    Tinari, D. F.

    1968-01-01

    Harmonic distortion analyzer effects rapid and accurate setup and calibration of magnetic tape instrumentation recorders. The analyzer is portable, requires no warmup period and need not be calibrated for normal usage. Average setup time with this analyzer is approximately 30 seconds per track.

  3. Theoretical analysis on ac susceptibility measurements of superconductor tapes

    NASA Astrophysics Data System (ADS)

    Chen, Du-Xing; Sun, Yue-Ming; Li, Shuo; Fang, Jin

    2017-02-01

    Perpendicular ac susceptibility χ ={χ\\prime}-j{χ\\prime \\prime} of a superconducting long tape defined by magnetic moment and determined inductively by magnetic flux is calculated using Brandt’s technique from a power-law dependence of electric field on sheet current density. The requirements of χ measurements to the experimental setup and procedure are discussed based on the calculation results.

  4. Tape casting and partial melting of Bi-2212 thick films

    NASA Technical Reports Server (NTRS)

    Buhl, D.; Lang, TH.; Heeb, B.; Gauckler, L. J.

    1995-01-01

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 microns. The orientation of the (a,b)-plane of the grains was parallel to the substrate with a misalignment of less than 6 deg. At 77 K/0T a critical current density of 15, 000 A/sq cm was reached in films of the dimension 1 cm x 2 cm x 20 microns (1 micron V/cm criterion, resistively measured). At 4 K/0T the highest value was 350,000 A/sq cm (1 nV/cm criterion, magnetically measured).

  5. Nucleate boiling of water in twisted-tape swirled flow

    SciTech Connect

    Kudryavtsev, I.S.; Lekakh, B.M.; Paskar, B.L.; Fedorovich, Y.D. )

    1990-01-01

    This paper analyzes nucleate boiling in twisted-tape swirled water flow. The transverse flow velocity in the wall region, generated by the density gradient and acceleration, is estimated. It is concluded that the turbulence has a significant effect on the growth of vapor bubbles, decreasing the rate of nucleate boiling without simultaneously increasing the convective component to compensate for this effect.

  6. A new tape product for optical data storage

    NASA Technical Reports Server (NTRS)

    Larsen, T. L.; Woodard, F. E.; Pace, S. J.

    1993-01-01

    A new tape product has been developed for optical data storage. Laser data recording is based on hole or pit formation in a low melting metallic alloy system. The media structure, sputter deposition process, and media characteristics, including write sensitivity, error rates, wear resistance, and archival storage are discussed.

  7. Influence of technology on magnetic tape storage device characteristics

    NASA Technical Reports Server (NTRS)

    Gniewek, John J.; Vogel, Stephen M.

    1994-01-01

    There are available today many data storage devices that serve the diverse application requirements of the consumer, professional entertainment, and computer data processing industries. Storage technologies include semiconductors, several varieties of optical disk, optical tape, magnetic disk, and many varieties of magnetic tape. In some cases, devices are developed with specific characteristics to meet specification requirements. In other cases, an existing storage device is modified and adapted to a different application. For magnetic tape storage devices, examples of the former case are 3480/3490 and QIC device types developed for the high end and low end segments of the data processing industry respectively, VHS, Beta, and 8 mm formats developed for consumer video applications, and D-1, D-2, D-3 formats developed for professional video applications. Examples of modified and adapted devices include 4 mm, 8 mm, 12.7 mm and 19 mm computer data storage devices derived from consumer and professional audio and video applications. With the conversion of the consumer and professional entertainment industries from analog to digital storage and signal processing, there have been increasing references to the 'convergence' of the computer data processing and entertainment industry technologies. There has yet to be seen, however, any evidence of convergence of data storage device types. There are several reasons for this. The diversity of application requirements results in varying degrees of importance for each of the tape storage characteristics.

  8. Educators Guide to Free Tapes, Scripts, and Transcriptions. Eighteenth Edition.

    ERIC Educational Resources Information Center

    Wittich, Walter A., Ed.; And Others

    This compendium lists 442 tapes, scripts, and transcriptions which are available free of cost to schools and libraries. Of these titles, 259 are new this year. Forty-one of the titles may be kept permanently by the user. Cassettes and videotapes are included in this edition for the first time. The items are listed by topics; accident prevention…

  9. Self-Paced Physics [Talking Book Cassette Tapes].

    ERIC Educational Resources Information Center

    New York Inst. of Tech., Old Westbury.

    As one of three audiovisual media in the U. S. Naval Academy Self-Paced Physics Course, 16 cassette tapes relating to lectures of mechanics, electricity, and magnetism are prepared for enriching and supplementary purposes. The material is designed to be used in combination with the talking book where illustrations, formulas, behavioral objectives,…

  10. The Taped Monologue as Narrative Technique for Reflective Practice

    ERIC Educational Resources Information Center

    Ford, Keith

    2016-01-01

    In this article, I describe how an EFL teacher engaged in a process of reflective practice. As she looked back on her teaching career, she explored the critical incidents, principles, and practices that have informed her present teaching identity. I focus on how a taped monologue narrative technique was used, and on the rationale, practice, and…

  11. STS-46 Special Events Resource Tape, Part 1 of 2

    NASA Technical Reports Server (NTRS)

    1992-01-01

    Footage shows the inflight interviews of the crew of the STS-46 Atlantis Orbiter. An Italian VIP call and press conference (both spoken in Italian) are seen, and Mission Specialist Franklin R. Chang-Diaz participates in a Costa Rican VIP call (spoken in Spanish). See also 'STS-46 Special Events Resource Tape, Part 2 of 2'.

  12. Tape casting and partial melting of Bi-2212 thick films

    SciTech Connect

    Buhl, D.; Lang, T.; Heeb, B.

    1994-12-31

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 {mu}m. The orientation of the (a,b)-plane of the grains were parallel to the substrate with a misalignment of less than 6{degrees}. At 77K/OT a critical current density of 15`000 A/cm{sup 2} was reached in films of the dimension 1cm x 2cm x 20{mu}m (1{mu}V/cm criterion, resistively measured). At 4K/OT the highest value was 350`000 A/cm{sup 2} (1nV/cm criterion, magnetically measured).

  13. Projector Center: Slide-Tape Presentations on a Classroom Budget.

    ERIC Educational Resources Information Center

    Barman, Charles R., Ed.

    1984-01-01

    Presented is a recommended sequence for developing a slide-tape presentation. Steps include selecting a topic, determining objectives for the presentation, constructing a storyboard, writing the script, and recording the script. Comments on use of quotation, sound effects, built-in pauses, and use of student voices are included. (JN)

  14. 16 CFR 1632.7 - Tape edge substitution procedure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Tape edge substitution procedure. 1632.7 Section 1632.7 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT REGULATIONS STANDARD FOR THE FLAMMABILITY OF MATTRESSES AND MATTRESS PADS (FF 4-72, AMENDED) The Standard § 1632.7...

  15. 16 CFR 1632.7 - Tape edge substitution procedure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Tape edge substitution procedure. 1632.7 Section 1632.7 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT REGULATIONS STANDARD FOR THE FLAMMABILITY OF MATTRESSES AND MATTRESS PADS (FF 4-72, AMENDED) The Standard § 1632.7...

  16. Recorded Readings: A Taped Parent-Tutoring Intervention

    ERIC Educational Resources Information Center

    Kupzyk, Sara; McCurdy, Merilee; Hofstadter, Kristi L.; Berger, Laura

    2011-01-01

    Parent tutoring has been successfully used to increase children's oral reading fluency. However, commonly used procedures pose a challenge for parents who are not proficient in reading or who speak English as a second language. A taped reading program that included listening passage preview, repeated reading, and performance feedback was developed…

  17. Self-Help Audiocassette Tapes: Adjunct to Psychological Counseling.

    ERIC Educational Resources Information Center

    Yamauchi, Kent T.

    1987-01-01

    Argues that use of self-help audiocassette tapes in psychological counseling can accelerate the introduction of therapeutic ideas, promote continuity of counseling between sessions, and reinforce behavioral and attitudinal changes. Discussed rationale and description of a program in which this approach is used in brief counseling of college…

  18. Flexible storage medium for write-once optical tape

    NASA Technical Reports Server (NTRS)

    Strandjord, Andrew J. G.; Webb, Steven P.; Perettie, Donald J.; Cipriano, Robert A.

    1993-01-01

    A write-once data storage media was developed which is suitable for optical tape applications. The media is manufactured using a continuous film process to deposit a ternary alloy of tin, bismuth, and copper. This laser sensitive layer is sputter deposited onto commercial plastic web as a single-layer thin film. A second layer is sequentially deposited on top of the alloy to enhance the media performance and act as an abrasion resistant hard overcoat. The media was observed to have laser write sensitivities of less than 2.0 njoules/bit, carrier-to-noise levels of greater than 50dB's, modulation depths of approximately 100 percent, read-margins of greater than 35, uniform grain sizes of less than 200 Angstroms, and a media lifetime that exceeds 10 years. Prototype tape media was produced for use in the CREO drive system. The active and overcoat materials are first sputter deposited onto three mil PET film in a single pass through the vacuum coating system, and then converted down into multiple reels of 35mm x 880m tape. One mil PET film was also coated in this manner and then slit and packaged into 3480 tape cartridges.

  19. Advanced Shuttle Simulation Turbulence Tapes (SSTT) users guide

    NASA Technical Reports Server (NTRS)

    Tatom, F. B.; Smith, S. R.

    1981-01-01

    A nonrecursive model (based on von Karman spectra) for atmospheric turbulence along the flight path of the shuttle orbiter was developed which provides for simulation of instantaneous vertical and horizontal gusts at the vehicle center-of-gravity and also for simulation of instantaneous gust gradients. Based on this model, the time series for both gusts and gust gradients was generated and stored on a series of magnetic tapes which are entitled shuttle simulation turbulence tapes (SSTT). The time series are designed to represent atmospheric turbulence from ground level to an altitude of 120,000 meters. An appropriate description of the characteristics of the simulated turbulence stored on the tapes, as well as instructions regarding their proper use are provided. The characteristics of the turbulence series, including the spectral shape, cutoff frequencies, and variation of turbulence parameters with altitude, are discussed. Information regarding the tapes and their use is presented. Appendices provide results of spectral and statistical analyses of the SSTT and examples of how the SSTT should be used.

  20. Magnetic and Electrical Characteristics of Permalloy Thin Tape Bobbin Cores

    NASA Technical Reports Server (NTRS)

    Schwarze, Gene E.; Wieserman, William R.; Niedra, Janis M.

    2005-01-01

    The core loss, that is, the power loss, of a soft ferromagnetic material is a function of the flux density, frequency, temperature, excitation type (voltage or current), excitation waveform (sine, square, etc.) and lamination or tape thickness. In previously published papers we have reported on the specific core loss and dynamic B-H loop results for several polycrystalline, nanocrystalline, and amorphous soft magnetic materials. In this previous research we investigated the effect of flux density, frequency, temperature, and excitation waveform for voltage excitation on the specific core loss and dynamic B-H loop. In this paper, we will report on an experimental study to investigate the effect of tape thicknesses of 1, 1/2, 1/4, and 1/8-mil Permalloy type magnetic materials on the specific core loss. The test cores were fabricated by winding the thin tapes on ceramic bobbin cores. The specific core loss tests were conducted at room temperature and over the frequency range of 10 kHz to 750 kHz using sine wave voltage excitation. The results of this experimental investigation will be presented primarily in graphical form to show the effect of tape thickness, frequency, and magnetic flux density on the specific core loss. Also, the experimental results when applied to power transformer design will be briefly discussed.

  1. Privacy: The Reporter, the Telephone, and the Tape Recorder.

    ERIC Educational Resources Information Center

    Riley, Sam G.; Wiessler, Joel M.

    Federal and state law provides, for the most part, little specific guidance to persons tape recording their own telephone calls for their own record-keeping purposes. In a specific case, a Pennsylvania newsman was prosecuted in 1972 on charges of wiretapping his own telephone conversations without notice to the other parties in the calls. A review…

  2. User's guide to the UTIL-ODRC tape processing program. [for the Orbital Data Reduction Center

    NASA Technical Reports Server (NTRS)

    Juba, S. M. (Principal Investigator)

    1981-01-01

    The UTIL-ODRC computer compatible tape processing program, its input/output requirements, and its interface with the EXEC 8 operating system are described. It is a multipurpose orbital data reduction center (ODRC) tape processing program enabling the user to create either exact duplicate tapes and/or tapes in SINDA/HISTRY format. Input data elements for PRAMPT/FLOPLT and/or BATCH PLOT programs, a temperature summary, and a printed summary can also be produced.

  3. Generation and physical characteristics of the Landsat 1 and 2 MSS computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1975-01-01

    The generation and format is discussed of the Landsat 1 and 2 system corrected multispectral scanner computer compatible tapes. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes at the NASA Data Processing Facility. Geometric and radiometric corrections, tape formats, and the physical characteristics of the tape are also described.

  4. Playback Station #2 for Cal Net and 5-day-recorder tapes

    USGS Publications Warehouse

    Eaton, Jerry P.

    1978-01-01

    A second system (Playback Station #2) has been set up to play back Cal Net 1" tapes and 5-day-recorder 1/2" tapes. As with the first playback system (Playback Station #1) the tapes are played back on a Bell and Howell VR3700B tape deck and the records are written out on a 16-channel direct-writing Siemens "0scillomink." Separate reproduce heads, tape guides, and tape tension sensor rollers are required for playing back 111 tapes and 1/2" tapes, but changing these tape deck components is a simple task that requires only a few minutes. The discriminators, patch panels, selector switches, filters, time code translators, and signal conditioning circuits for the time code translators and for the tape-speed-compensation signal are all mounted in an equipment rack that stands beside the playback tape deck. Changing playback speeds (15/16 ips or 3 3/4 ips) or changing from Cal Net tapes to 5-day-recorder tapes requires only flipping a few switches and/or changing a few patch cables on the patch panel (in addition to changing the reproduce heads, etc., to change from 1" tape to 1/2" tape). For the Cal Net tapes, the system provides for playback of 9 data channels (680 Hz thru 3060 Hz plus 400 Hz) and 3 time signals (IRIG-E, IRIG-C, and WWVB) at both 15/16 ips (x1 speed) and 3 3/4 ips (x4 speed). Available modes of compensation (using either a 4688 Hz reference or a 3125 Hz reference) are subtractive, capstan, capstan plus subtractive, or no compensation.

  5. Apparatus and method for loading and unloading multiple digital tape cassettes utilizing a removable magazine

    DOEpatents

    Lindenmeyer, C.W.

    1993-01-26

    An apparatus and method to automate the handling of multiple digital tape cassettes for processing by commercially available cassette tape readers and recorders. A removable magazine rack stores a plurality of tape cassettes, and cooperates with a shuttle device that automatically inserts and removes cassettes from the magazine to the reader and vice-versa. Photocells are used to identify and index to the desired tape cassette. The apparatus allows digital information stored on multiple cassettes to be processed without significant operator intervention.

  6. Apparatus and method for loading and unloading multiple digital tape cassettes utilizing a removable magazine

    DOEpatents

    Lindenmeyer, Carl W.

    1993-01-01

    An apparatus and method to automate the handling of multiple digital tape cassettes for processing by commercially available cassette tape readers and recorders. A removable magazine rack stores a plurality of tape cassettes, and cooperates with a shuttle device that automatically inserts and removes cassettes from the magazine to the reader and vice-versa. Photocells are used to identify and index to the desired tape cassette. The apparatus allows digital information stored on multiple cassettes to be processed without significant operator intervention.

  7. Reduction of postoperative adhesion development.

    PubMed

    Diamond, Michael P

    2016-10-01

    Despite use of meticulous surgical techniques, and regardless of surgical access via laparotomy or laparoscopy, postoperative adhesions develop in the vast majority of women undergoing abdominopelvic surgery. Such adhesions represent not only adhesion reformation at sites of adhesiolysis, but also de novo adhesion formation at sites of surgical procedures. Application of antiadhesion adjuvants compliment the benefits of meticulous surgical techniques, providing an opportunity to further reduce postoperative adhesion development. Improved understanding of the pathophysiology of adhesion development and distinguishing variations in the molecular biologic mechanisms from adhesion-free peritoneal repair represent future opportunities to improve the reduction of postoperative adhesions. Optimization of the reduction of postoperative adhesions will likely require identification of unique, personalized approaches in each individual, representing interindividual variation in peritoneal repair processes.

  8. Magnetic field switchable dry adhesives.

    PubMed

    Krahn, Jeffrey; Bovero, Enrico; Menon, Carlo

    2015-02-04

    A magnetic field controllable dry adhesive device is manufactured. The normal adhesion force can be increased or decreased depending on the presence of an applied magnetic field. If the magnetic field is present during the entire normal adhesion test cycle which includes both applying a preloading force and measuring the pulloff pressure, a decrease in adhesion is observed when compared to when there is no applied magnetic field. Similarly, if the magnetic field is present only during the preload portion of the normal adhesion test cycle, a decrease in adhesion is observed because of an increased stiffness of the magnetically controlled dry adhesive device. When the applied magnetic field is present during only the pulloff portion of the normal adhesion test cycle, either an increase or a decrease in normal adhesion is observed depending on the direction of the applied magnetic field.

  9. Adhesion and wetting: Similarities and differences

    SciTech Connect

    Shanahan, M.E.R. )

    1991-10-01

    This article examines what is understood about adhesion and wetting both from the historical and scientific perspectives. Topics covered include mechanical adhesion, specific adhesion, chemical adhesion, adhesion by diffusion, the adsorption or wetting theory, bulk adhesion, the rheological theory, hysteresis effects in rubber adhesion, and hysteresis of wetting.

  10. Mechanisms of self-cleaning in fluid-based smooth adhesive pads of insects.

    PubMed

    Clemente, Christofer J; Federle, Walter

    2012-12-01

    Pressure-sensitive adhesives such as tapes become easily contaminated by dust particles. By contrast, animal adhesive pads are able to self-clean and can be reused millions of times over a lifetime with little reduction in adhesion. However, the detailed mechanisms underlying this ability are still unclear. Here we test in adhesive pads of stick insects (Carausius morosus) (1) whether self-cleaning is enhanced by the liquid pad secretion, and (2) whether alternating push-pull movements aid the removal of particles. We measured attachment forces of insect pads on glass after contamination with 10 µm polystyrene beads. While the amount of fluid present on the pad showed no effect on the pads' susceptibility to contamination, the recovery of adhesive forces after contamination was faster when higher fluid levels were present. However, this effect does not appear to be based on a faster rate of self-cleaning since the number of spheres deposited with each step did not increase with fluid level. Instead, the fluid may aid the recovery of adhesive forces by filling in the gaps between contaminating particles, similar to the fluid's function on rough surfaces. Further, we found no evidence that an alternation of pushing and pulling movements, as found in natural steps, leads to a more efficient recovery of adhesion than repeated pulling slides.

  11. Mapping cell surface adhesion by rotation tracking and adhesion footprinting

    NASA Astrophysics Data System (ADS)

    Li, Isaac T. S.; Ha, Taekjip; Chemla, Yann R.

    2017-03-01

    Rolling adhesion, in which cells passively roll along surfaces under shear flow, is a critical process involved in inflammatory responses and cancer metastasis. Surface adhesion properties regulated by adhesion receptors and membrane tethers are critical in understanding cell rolling behavior. Locally, adhesion molecules are distributed at the tips of membrane tethers. However, how functional adhesion properties are globally distributed on the individual cell’s surface is unknown. Here, we developed a label-free technique to determine the spatial distribution of adhesive properties on rolling cell surfaces. Using dark-field imaging and particle tracking, we extract the rotational motion of individual rolling cells. The rotational information allows us to construct an adhesion map along the contact circumference of a single cell. To complement this approach, we also developed a fluorescent adhesion footprint assay to record the molecular adhesion events from cell rolling. Applying the combination of the two methods on human promyelocytic leukemia cells, our results surprisingly reveal that adhesion is non-uniformly distributed in patches on the cell surfaces. Our label-free adhesion mapping methods are applicable to the variety of cell types that undergo rolling adhesion and provide a quantitative picture of cell surface adhesion at the functional and molecular level.

  12. Mapping cell surface adhesion by rotation tracking and adhesion footprinting

    PubMed Central

    Li, Isaac T. S.; Ha, Taekjip; Chemla, Yann R.

    2017-01-01

    Rolling adhesion, in which cells passively roll along surfaces under shear flow, is a critical process involved in inflammatory responses and cancer metastasis. Surface adhesion properties regulated by adhesion receptors and membrane tethers are critical in understanding cell rolling behavior. Locally, adhesion molecules are distributed at the tips of membrane tethers. However, how functional adhesion properties are globally distributed on the individual cell’s surface is unknown. Here, we developed a label-free technique to determine the spatial distribution of adhesive properties on rolling cell surfaces. Using dark-field imaging and particle tracking, we extract the rotational motion of individual rolling cells. The rotational information allows us to construct an adhesion map along the contact circumference of a single cell. To complement this approach, we also developed a fluorescent adhesion footprint assay to record the molecular adhesion events from cell rolling. Applying the combination of the two methods on human promyelocytic leukemia cells, our results surprisingly reveal that adhesion is non-uniformly distributed in patches on the cell surfaces. Our label-free adhesion mapping methods are applicable to the variety of cell types that undergo rolling adhesion and provide a quantitative picture of cell surface adhesion at the functional and molecular level. PMID:28290531

  13. Adhesive particle shielding

    DOEpatents

    Klebanoff, Leonard Elliott; Rader, Daniel John; Walton, Christopher; Folta, James

    2009-01-06

    An efficient device for capturing fast moving particles has an adhesive particle shield that includes (i) a mounting panel and (ii) a film that is attached to the mounting panel wherein the outer surface of the film has an adhesive coating disposed thereon to capture particles contacting the outer surface. The shield can be employed to maintain a substantially particle free environment such as in photolithographic systems having critical surfaces, such as wafers, masks, and optics and in the tools used to make these components, that are sensitive to particle contamination. The shield can be portable to be positioned in hard-to-reach areas of a photolithography machine. The adhesive particle shield can incorporate cooling means to attract particles via the thermophoresis effect.

  14. The effectiveness of kinesio taping for athletes with medial elbow epicondylar tendinopathy.

    PubMed

    Chang, H-Y; Cheng, S-C; Lin, C-C; Chou, K-Y; Gan, S-M; Wang, C-H

    2013-11-01

    Kinesio taping has also been used for athletes with Medial Elbow Epicondylar Tendinopathy (MET) as an additional treatment method. The purpose of this study was to determine the clinical effectiveness of Kinesio tape on maximal grip strength and absolute and related force sense in athletes with MET when applied to the medial forearm. 27 male athletes who voluntarily participated in this study were divided into a healthy group (n=17) and a MET group (n=10). All subjects were assessed for the maximal grip strength and grip force sense (absolute and related force sense) under 3 taping conditions: 1) without taping; 2) with placebo Kinesio taping; and 3) with Kinesio taping. No significant interaction was found between groups and taping condition in maximal grip force and related force sense error, except for absolute force sense error (p=0.04). Both groups with absolute force sense measurements had significantly decreased errors in the placebo Kinesio taping and Kinesio taping conditions. Both taping may enhance discrimination of magnitude of grip force control (absolute force sense) in both groups when applied to the forearm. However, Kinesio taping did not change maximal grip strength in either group. The effects of Kinesio taping on other muscle functions remain to be studied.

  15. Effect of two different kinesio taping techniques on knee kinematics and kinetics in young females.

    PubMed

    Guner, Senem; Alsancak, Serap; Koz, Mitat

    2015-10-01

    [Purpose] The application of kinesio taping may improve strength and performance, inhibit and facilitate motor activity, and increase range of motion. The aim of this study was to compare the effects of kinesio taping facilitation and inhibition applications on spatiotemporal knee kinematics and kinetics during walking activity in healthy subjects. [Subjects and Methods] A three-dimensional quantitative gait evaluation was performed without tape and with, facilitation and inhibition kinesio taping application on the knee. Sixteen healthy female college students (age, 19.7 ± 0.4 years; height, 1.64 ± 3.4 cm; body mass, 51.5 ± 4.8 kg) participated in the study. [Results] Spatiotemporal parameters (cadence, walking speed, stride length) were significantly different among the trials. Knee joint sagittal plane range of motion was not different with either kinesio taping application. Knee external flexion moment during the early stance phase decreased significantly with facilitation kinesio taping and increased with the inhibition kinesio taping. Knee external extension moment during the mid-stance phase increased with facilitation kinesio taping. Knee power parameters, eccentric activity in the rectus femoris during the pre-swing phase was significantly increased with inhibition kinesio taping application, while eccentric activity of the hamstrings during the terminal swing of gait was decreased. [Conclusion] These findings showed that facilitation kinesio taping application affected the terminal stance phase and that inhibition kinesio taping influenced the terminal swing phase compared with the no tape condition.

  16. Effect of two different kinesio taping techniques on knee kinematics and kinetics in young females

    PubMed Central

    Guner, Senem; Alsancak, Serap; Koz, Mitat

    2015-01-01

    [Purpose] The application of kinesio taping may improve strength and performance, inhibit and facilitate motor activity, and increase range of motion. The aim of this study was to compare the effects of kinesio taping facilitation and inhibition applications on spatiotemporal knee kinematics and kinetics during walking activity in healthy subjects. [Subjects and Methods] A three-dimensional quantitative gait evaluation was performed without tape and with, facilitation and inhibition kinesio taping application on the knee. Sixteen healthy female college students (age, 19.7 ± 0.4 years; height, 1.64 ± 3.4 cm; body mass, 51.5 ± 4.8 kg) participated in the study. [Results] Spatiotemporal parameters (cadence, walking speed, stride length) were significantly different among the trials. Knee joint sagittal plane range of motion was not different with either kinesio taping application. Knee external flexion moment during the early stance phase decreased significantly with facilitation kinesio taping and increased with the inhibition kinesio taping. Knee external extension moment during the mid-stance phase increased with facilitation kinesio taping. Knee power parameters, eccentric activity in the rectus femoris during the pre-swing phase was significantly increased with inhibition kinesio taping application, while eccentric activity of the hamstrings during the terminal swing of gait was decreased. [Conclusion] These findings showed that facilitation kinesio taping application affected the terminal stance phase and that inhibition kinesio taping influenced the terminal swing phase compared with the no tape condition. PMID:26644651

  17. 75 FR 8925 - Pressure Sensitive Plastic Tape from Italy: Preliminary Results of Antidumping Duty Changed...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-26

    ... International Trade Administration Pressure Sensitive Plastic Tape from Italy: Preliminary Results of... pressure sensitive plastic tape from Italy pursuant to section 751(b) of the Tariff Act of 1930, as amended... review request. See Pressure Sensitive Plastic Tape from Italy: Notice of Initiation of Antidumping...

  18. 75 FR 27706 - Pressure Sensitive Plastic Tape From Italy: Final Results of Antidumping Duty Changed...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-18

    ... Sensitive Plastic Tape From Italy: Final Results of Antidumping Duty Changed Circumstances Review AGENCY... Sensitive Plastic Tape from Italy: Preliminary Results of Antidumping Duty Changed Circumstances Review, 75... Plastic Tape from Italy: Notice of Initiation of Antidumping Duty Changed Circumstances Review, 74...

  19. Report of the Tape Recorder Action Plan Committee, 21 March 1972

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A NASA/AF Tape Recorder Action Plan Committee was formed in January 1972 to investigate tape recorder problems and to recommend an action plan to NASA management. The committee collected data on tape recorder failure history, pinpointed problem areas, discussed needed technical and management changes, and proposed an action plan for the recommended approaches.

  20. Parent Education Audiocassettes: Self-Help Tapes for Parents of Preschool and School-Age Children.

    ERIC Educational Resources Information Center

    Achievement, Inc., Hicksville, NY.

    Directed at the parents of preschool and elementary school children, this document consists of a collection of the informational brochures, catalogs, promotional materials, price lists, and order forms for a series of audiocassette tapes. All tapes are commercially available from Achievement Inc. Titles of tapes available are as follows: (1)…