  1. Column Liquid Chromatography.

    ERIC Educational Resources Information Center

    Majors, Ronald E.; And Others

    1984-01-01

    Reviews literature covering developments of column liquid chromatography during 1982-83. Areas considered include: books and reviews; general theory; columns; instrumentation; detectors; automation and data handling; multidimensional chromatographic and column switching techniques; liquid-solid chromatography; normal bonded-phase, reversed-phase,…

  2. Measurement of free thyroid hormones in serum by column adsorption chromatography and radioimmunoassay.

    PubMed

    Romelli, P B; Pennisi, F; Vancheri, L

    1979-01-01

    A new method for the assay of free thyroid hormones in human serum is described. This method is based on a chromatographic adsorption process of thyroid hormones onto a Sephadex LH-20 resin column. Protein fractions are eliminated by washing columns, adsorbed hormones are eluted with methanol and determined by radioimmunoassay. It was demonstrated that under the experimental conditions adopted the presence of the resin R does not significantly change the free hormone level in the serum, and the amount of hormone adsorbed onto the resin HR is exclusively in function of the free hormone concentration [H], according to a linear relationship: HR = phi [H], where phi is the resin adsorption constant K ads multiplied by the number of resin binding sites nR. The phi value, experimentally determined, was 32 ml for T3 and 58 ml for T4, when 150 mg resin were used. The method sensitivity was 0.3 pg/ml for FT3 and 0.6 pg/ml for FT4. The within-assay reproducibility was about 5% (CV) and the between-assay reproducibility was about 6% (CV), both for FT3 and FT4. FT3 and FT4 levels, in 96 normal subjects, were 3.9 +/- 0.7 pg/ml (mean +/- SD) and 11.1 +/- 1.9 pg/ml (mean +/- SD) respectively. PMID:489914

  3. Self-regenerating column chromatography

    SciTech Connect

    Park, Woo K.

    1994-12-31

    The present invention provides a process for treating both cations and anions by using a self-regenerating, multi-ionic exchange resin column system which requires no separate regeneration steps. The process involves alternation ion-exchange chromatography for cations and anions in a multi-ionic exchange column packed with a mixture of cation and anion exchange resins. The multi-ionic mixed-charge resin column works as a multifunction column, capable of independently processing either cationic or anionic exchange, or simultaneously processing both cationic and anionic exchanges. The major advantage offered by the alternating multifunction ion exchange process is the self-regeneration of the resins. Applications are to separation of nitrogen and sulfur isotopes.

  4. Self-regenerating column chromatography

    DOEpatents

    Park, W.K.

    1995-05-30

    The present invention provides a process for treating both cations and anions by using a self-regenerating, multi-ionic exchange resin column system which requires no separate regeneration steps. The process involves alternating ion-exchange chromatography for cations and anions in a multi-ionic exchange column packed with a mixture of cation and anion exchange resins. The multi-ionic mixed-charge resin column works as a multi-function column, capable of independently processing either cationic or anionic exchange, or simultaneously processing both cationic and anionic exchanges. The major advantage offered by the alternating multi-function ion exchange process is the self-regeneration of the resins.

  5. Triangular Helical Column for Centrifugal Countercurrent Chromatography.

    PubMed

    Ito, Yoichiro; Yu, Henry

    2009-01-01

    Effective column space and stationary phase retention have been improved by changing the configuration of the helical column originally used for toroidal coil countercurrent chromatography. The use of an equilateral triangular core for the helix column doubles effective column space and retains the stationary phase over 40% of the total column capacity without increasing the column pressure. The present results suggest that the stationary phase retention and the peak resolution will be further improved using new column designs fabricated by a new technology called "laser sintering for rapid prototyping." PMID:20046940

  6. Temperature programmable microfabricated gas chromatography column

    DOEpatents

    Manginell, Ronald P.; Frye-Mason, Gregory C.

    2003-12-23

    A temperature programmable microfabricated gas chromatography column enables more efficient chemical separation of chemical analytes in a gas mixture by the integration of a resistive heating element and temperature sensing on the microfabricated column. Additionally, means are provided to thermally isolate the heated column from their surroundings. The small heat capacity and thermal isolation of the microfabricated column improves the thermal time response and power consumption, both important factors for portable microanalytical systems.

  7. Tritium Isotope Separation Using Adsorption-Distillation Column

    SciTech Connect

    Fukada, Satoshi

    2005-07-15

    In order to miniaturize the height of a distillation tower for the detritiation of waste water from fusion reactors, two experiments were conducted: (1) liquid frontal chromatography of tritium water eluting through an adsorption column and (2) water distillation using a column packed with adsorbent particles. The height of the distillation tower depends on the height equivalent to a theoretical plate, HETP, and the equilibrium isotope separation factor, {alpha}{sub H-T}{sup equi}. The adsorption action improved not only HETP but also {alpha}{sub H-T}{sup equi}. Since the adsorption-distillation method proposed here can shorten the tower height with keeping advantages of the distillation, it may bring an excellent way for miniaturizing the distillation tower to detritiate a large amount of waste water from fusion reactors.

  8. Use of a polystyrene-divinylbenzene-based weakly acidic cation-exchange resin column and propionic acid as an eluent in ion-exclusion/adsorption chromatography of aliphatic carboxylic acids and ethanol in food samples.

    PubMed

    Mori, Masanobu; Hironaga, Takahiro; Kajiwara, Hiroe; Nakatani, Nobutake; Kozaki, Daisuke; Itabashi, Hideyuki; Tanaka, Kazuhiko

    2011-01-01

    We developed an ion-exclusion/adsorption chromatography (IEAC) method employing a polystyrene-divinylbenzene-based weakly acidic cation-exchange resin (PS-WCX) column with propionic acid as the eluent for the simultaneous determination of multivalent aliphatic carboxylic acids and ethanol in food samples. The PS-WCX column well resolved mono-, di-, and trivalent carboxylic acids in the acidic eluent. Propionic acid as the eluent gave a higher signal-to-noise ratio, and enabled sensitive conductimetric detection of analyte acids. We found the optimal separation condition to be the combination of a PS-WCX column and 20-mM propionic acid. Practical applicability of the developed method was confirmed by using a short precolumn with a strongly acidic cation-exchange resin in the H(+)-form connected before the separation column; this was to remove cations from food samples by converting them to hydrogen ions. Consequently, common carboxylic acids and ethanol in beer, wine, and soy sauce were successfully separated by the developed method. PMID:21558657

  9. "Dry-column" chromatography of plant pigments

    NASA Technical Reports Server (NTRS)

    Woeller, F. H.; Lehwalt, M. F.; Oyama, V. I.

    1973-01-01

    Separation of plant pigments which can be accomplished on thin-layer silica plates with mixture of petroleum ether, halocarbon, acetone, and polar solvent can be readily translated into dry-column technique that yields reproducible chromatograms after elution in fashion of liquid chromatography with fluorimeter as detector. Best solvent system was found to be mixture of petroleum ether, dichloromethane, acetone, and ethyl acetate.

  10. Non-planar microfabricated gas chromatography column

    DOEpatents

    Lewis, Patrick R.; Wheeler, David R.

    2007-09-25

    A non-planar microfabricated gas chromatography column comprises a planar substrate having a plurality of through holes, a top lid and a bottom lid bonded to opposite surfaces of the planar substrate, and inlet and outlet ports for injection of a sample gas and elution of separated analytes. A plurality of such planar substrates can be aligned and stacked to provide a longer column length having a small footprint. Furthermore, two or more separate channels can enable multi-channel or multi-dimensional gas chromatography. The through holes preferably have a circular cross section and can be coated with a stationary phase material or packed with a porous packing material. Importantly, uniform stationary phase coatings can be obtained and band broadening can be minimized with the circular channels. A heating or cooling element can be disposed on at least one of the lids to enable temperature programming of the column.

  11. Planar gas chromatography column on aluminum plate with multi-walled carbon nanotubes as stationary phase

    NASA Astrophysics Data System (ADS)

    Platonov, I. A.; Platonov, V. I.; Pavelyev, V. S.

    2016-04-01

    The high selectivity of the adsorption layer for low-boiling alkanes is shown, the separation factor (α) couple iso-butane / butane is 1.9 at a column temperature of 50 °C.The paper presents sorption and selective properties of planar gas chromatography column on aluminum plate with multi-walled carbon nanotubes as the stationary phase.

  12. Critical conditions of polymer adsorption and chromatography on non-porous substrates.

    PubMed

    Cimino, Richard T; Rasmussen, Christopher J; Brun, Yefim; Neimark, Alexander V

    2016-07-15

    We present a novel thermodynamic theory and Monte Carlo simulation model for adsorption of macromolecules to solid surfaces that is applied for calculating the chain partition during separation on chromatographic columns packed with non-porous particles. We show that similarly to polymer separation on porous substrates, it is possible to attain three chromatographic modes: size exclusion chromatography at very weak or no adsorption, liquid adsorption chromatography when adsorption effects prevail, and liquid chromatography at critical conditions that occurs at the critical point of adsorption. The main attention is paid to the analysis of the critical conditions, at which the retention is chain length independent. The theoretical results are verified with specially designed experiments on isocratic separation of linear polystyrenes on a column packed with non-porous particles at various solvent compositions. Without invoking any adjustable parameters related to the column and particle geometry, we describe quantitatively the observed transition between the size exclusion and adsorption separation regimes upon the variation of solvent composition, with the intermediate mode occurring at a well-defined critical point of adsorption. A relationship is established between the experimental solvent composition and the effective adsorption potential used in model simulations. PMID:27089017

  13. Comparison of the adsorption mechanisms of pyridine in hydrophilic interaction chromatography and in reversed-phase aqueous liquid chromatography.

    PubMed

    Gritti, Fabrice; Pereira, Alberto dos Santos; Sandra, Pat; Guiochon, Georges

    2009-11-27

    The adsorption isotherms of pyridine were measured by frontal analysis (FA) on a column packed with shell particles of neat porous silica (Halo), using water-acetonitrile mixtures as the mobile phase at 295K. The isotherm data were measured for pyridine concentrations covering a dynamic range of four millions. The degree of heterogeneity of the surface was characterized by the adsorption energy distribution (AED) function calculated from the raw adsorption data, using the expectation-maximization (EM) procedure. The results showed that two different retention mechanisms dominate in Per aqueous liquid chromatography (PALC) at low acetonitrile concentrations and in hydrophilic interaction chromatography (HILIC) at high acetonitrile concentrations. In the PALC mode, the adsorption mechanism of pyridine on the silica surface is controlled by hydrophobic interactions that take place on very few and ultra-active adsorption sites, which might be pores on the irregular and rugose surface of the porous silica particles. The surface is seriously heterogeneous, with up to five distinct adsorption sites and five different energy peaks on the AED of the packing material. In contrast, in the HILIC mode, the adsorption behavior is quasi-homogeneous and pyridine retention is governed by its adsorption onto free silanol groups. For intermediate mobile phase compositions, the siloxane and the silanol groups are both significantly saturated with acetonitrile and water, respectively, causing a minimum of the retention factor of pyridine on the Halo column. PMID:19853257

  14. Surface modification of polytetrafluoroethylene column for two-stationary phase separations by counter-current chromatography.

    PubMed

    Quan, Kai-jun; Huang, Xin-yi; Li, Xiao-ting; Wang, Gao-hong; Liu, Yan-juan; Duan, Wen-da; Di, Duo-long

    2015-11-27

    To improve the separation capability of CCC, a novel solid-liquid two-stationary phases CCC (ASP-CCC) column was prepared employing graphene oxide (GO) conjugated poly-dopamine (PD) coating (GO/PD) as auxiliary stationary phase (ASP). The results of Scanning electron microscopy (SEM), contact angle and X-ray photoelectron spectroscopy (XPS) indicated that nanostructured GO and PD were successfully grafted on the inner wall of the PTFE column. Three alkaloid compounds were selected as the target analytes to evaluate the performance of the novel column. Because of the intermolecular force (hydrogen bond, electrostatic interaction and π-π interaction) between the ASP and model compounds, three analytes were well separated with this novel ASP-CCC column. Additionally, the novel column exhibited higher stationary phase retention ratio, about 8%, than original column without changing the chromatographic condition. Furthermore, the eluotropic sequence of analytes on novel column was in accordance with that in the original column. This suggested that the novel column is a CCC column with auxiliary stationary phase (ASP) in its own right, and the present separation mode is the combination of partition chromatography and adsorption chromatography. PMID:26518492

  15. Ion Exchange and Liquid Column Chromatography.

    ERIC Educational Resources Information Center

    Walton, Harold F.

    1980-01-01

    Emphasizes recent advances in principles and methodology in ion exchange and chromatography. Two tables list representative examples for inorganic ions and organic compounds. Cites 544 references. (CS)

  16. Combining micro dry column chromatography and mass spectrometry

    NASA Technical Reports Server (NTRS)

    Bauman, A. J.

    1970-01-01

    Dry column chromatography principles applied in microscale produce technique to minimize time in preparing and analyzing colorless constituents of soluble mixtures. Glass pipette microcolumns filled with finely sieved adsorbents permit capillary attraction and separation in 3 to 15 minutes. Technique is adaptable to gas chromatography.

  17. Effects of Cabin Upsets on Adsorption Columns for Air Revitalization

    NASA Technical Reports Server (NTRS)

    LeVan, Douglas

    1999-01-01

    The National Aeronautics and Space Administration (NASA) utilizes adsorption technology as part of contaminant removal systems designed for long term missions. A variety of trace contaminants can be effectively removed from gas streams by adsorption onto activated carbon. An activated carbon adsorption column meets NASA's requirements of a lightweight and efficient means of controlling trace contaminant levels aboard spacecraft and space stations. The activated carbon bed is part of the Trace Contaminant Control System (TCCS) which is utilized to purify the cabin atmosphere. TCCS designs oversize the adsorption columns to account for irregular fluctuations in cabin atmospheric conditions. Variations in the cabin atmosphere include changes in contaminant concentrations, temperature, and relative humidity. Excessively large deviations from typical conditions can result from unusual crew activity, equipment malfunctions, or even fires. The research carried out under this award focussed in detail on the effects of cabin upsets on the performance of activated carbon adsorption columns. Both experiments and modeling were performed with an emphasis on the roll of a change in relative humidity on adsorption of trace contaminants. A flow through fixed-bed apparatus was constructed at the NASA Ames Research Center, and experiments were performed there. Modeling work was performed at the University of Virginia.

  18. A Better Method for Filling Pasteur Pipet Chromatography Columns

    ERIC Educational Resources Information Center

    Ruekberg, Ben

    2006-01-01

    An alternative method for the preparation of Pasteur pipet chromatography columns is presented that allows the column to be filled with solvent without bubbles and allows greater control of fluid flow while the materials to be separated are added. Students are required to wear gloves and goggles and caution should be used while handling glass…

  19. A versatile noninvasive method for adsorber quantification in batch and column chromatography based on the ionic capacity.

    PubMed

    Huuk, Thiemo C; Briskot, Till; Hahn, Tobias; Hubbuch, Jürgen

    2016-05-01

    Within the Quality by Design (QbD) framework proposed by the International Conference on Harmonisation (ICH), high-throughput process development (HTPD) and mechanistic modeling are of outstanding importance for future biopharmaceutical chromatography process development. In order to compare the data derived from different column scales or batch chromatographies, the amount of adsorber has to be quantified with the same noninvasive method. Similarly, an important requirement for the implementation of mechanistic modeling is the reliable determination of column characteristics such as the ionic capacity Λ for ion-exchange chromatography with the same method at all scales and formats. We developed a method to determine the ionic capacity in column and batch chromatography, based on the adsorption/desorption of the natural, uv-detectable amino acid histidine. In column chromatography, this method produces results comparable to those of classical acid-base titration. In contrast to acid-base titration, this method can be adapted to robotic batch chromatographic experiments. We are able to convert the adsorber volumes in batch chromatography to the equivalent volume of a compressed column. In a case study, we demonstrate that this method increases the quality of SMA parameters fitted to batch adsorption isotherms, and the capability to predict column breakthrough experiments. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 32:666-677, 2016. PMID:27324662

  20. Effects of Cabin Upsets on Adsorption Columns for Air Revitalization

    NASA Technical Reports Server (NTRS)

    LeVan, M. Douglas

    1999-01-01

    The National Aeronautics and Space Administration (NASA) utilizes adsorption technology as part of contaminant removal systems designed for long term missions. A variety of trace contaminants can be effectively removed from gas streams by adsorption onto activated carbon. An activated carbon adsorption column meets NASA's requirements of a lightweight and efficient means of controlling trace contaminant levels aboard spacecraft and space stations. The activated carbon bed is part of the Trace Contaminant Control System (TCCS) which is utilized to purify the cabin atmosphere. TCCS designs oversize the adsorption columns to account for irregular fluctuations in cabin atmospheric conditions. Variations in the cabin atmosphere include changes in contaminant concentrations, temperature, and relative humidity. Excessively large deviations from typical conditions can result from unusual crew activity, equipment malfunctions, or even fires. The research carried out under this award focussed in detail on the effects of cabin upsets on the performance of activated carbon adsorption columns. Both experiments and modeling were performed with an emphasis on the roll of a change in relative humidity on adsorption of trace contaminants. A flow through fixed-bed apparatus was constructed at the NASA Ames Research Center, and experiments were performed there by W. Scot Appel under the direction of Dr. John E. Finn. Modeling work was performed at the University of Virginia and at Vanderbilt University by W. Scot Appel under the direction of M. Douglas LeVan. All three participants collaborated in all of the various phases of the research. The most comprehensive document describing the research is the Ph.D. dissertation of W. Scot Appel. Results have been published in several papers and presented in talks at technical conferences. All documents have been transmitted to Dr. John E. Finn.

  1. Modeling Transport in Gas Chromatography Columns for the Micro-ChemLab

    SciTech Connect

    ADKINS,DOUGLAS R.; FRYE-MASON,GREGORY CHARLES; HUDSON,MARY L.; KOTTENSTETTE,RICHARD; MATZKE,CAROLYN M.; SALINGER,ANDREW G.; SHADID,JOHN N.; WONG, CHUNGNIN CHANN

    1999-09-01

    The gas chromatography (GC) column is a critical component in the microsystem for chemical detection ({mu}ChemLab{trademark}) being developed at Sandia. The goal is to etch a meter-long GC column onto a 1-cm{sup 2} silicon chip while maintaining good chromatographic performance. Our design strategy is to use a modeling and simulation approach. We have developed an analytical tool that models the transport and surface interaction process to achieve an optimized design of the GC column. This analytical tool has a flow module and a separation module. The flow module considers both the compressibility and slip flow effects that may significantly influence the gas transport in a long and narrow column. The separation module models analyte transport and physico-chemical interaction with the coated surface in the GC column. It predicts the column efficiency and performance. Results of our analysis will be presented in this paper. In addition to the analytical tool, we have also developed a time-dependent adsorption/desorption model and incorporated this model into a computational fluid dynamics (CFD) code to simulate analyte transport and separation process in GC columns. CFD simulations can capture the complex three-dimensional flow and transport dynamics, whereas the analytical tool cannot. Different column geometries have been studied, and results will be presented in this paper. Overall we have demonstrated that the modeling and simulation approach can guide the design of the GC column and will reduce the number of iterations in the device development.

  2. Design, testing, and simulation of microscale gas chromatography columns

    SciTech Connect

    Hudson, M.L.; Kottenstette, R.; Matzke, C.M.; Frye-Mason, G.C.; Shollenberger, K.A.; Adkins, D.R.; Wong, C.C.

    1998-08-01

    A microscale gas chromatography column is one component in a microscale chemistry laboratory for detecting chemical agents. Several columns were fabricated using the Bosch etch process which allows deep, high aspect ratio channels of rectangular cross-section. A design tool, based on analytical models, was developed to evaluate the effects of operating conditions and column specifications on separation resolution and time. The effects of slip flow, channel configuration, and cross-sectional shape were included to evaluate the differences between conventional round, straight columns and the microscale rectangular, spiral columns. Experimental data were obtained and compared with the predicted flowrates and theoretical number of plates. The design tool was then employed to select more optimum channel dimensions and operating conditions for high resolution separations.

  3. Column Chromatography To Obtain Organic Cation Sorption Isotherms.

    PubMed

    Jolin, William C; Sullivan, James; Vasudevan, Dharni; MacKay, Allison A

    2016-08-01

    Column chromatography was evaluated as a method to obtain organic cation sorption isotherms for environmental solids while using the peak skewness to identify the linear range of the sorption isotherm. Custom packed HPLC columns and standard batch sorption techniques were used to intercompare sorption isotherms and solid-water sorption coefficients (Kd) for four organic cations (benzylamine, 2,4-dichlorobenzylamine, phenyltrimethylammonium, oxytetracycline) with two aluminosilicate clay minerals and one soil. A comparison of Freundlich isotherm parameters revealed isotherm linearity or nonlinearity was not significantly different between column chromatography and traditional batch experiments. Importantly, skewness (a metric of eluting peak symmetry) analysis of eluting peaks can establish isotherm linearity, thereby enabling a less labor intensive means to generate the extensive data sets of linear Kd values required for the development of predictive sorption models. Our findings clearly show that column chromatography can reproduce sorption measures from conventional batch experiments with the benefit of lower labor-intensity, faster analysis times, and allow for consistent sorption measures across laboratories with distinct chromatography instrumentation. PMID:27379799

  4. Polyimide polymer glass-free capillary columns for gas chromatography.

    PubMed

    Webster, Jackie G; Marine, Susan S; Danielson, Neil D

    2011-01-01

    Polymeric polyimide capillary tubing, both uncoated and coated with stationary phases of two polarities, is explored for use as capillary columns for gas chromatography (GC). These glass-free polyimide columns are flexible and their small winding diameter of less than a cm around a solid support makes them compatible for potential use in portable GC instruments. Polyimide columns with dimensions of 0.32 mm i.d. × 3 m are cleaned, annealed at 300°C, and coated using the static method with phenylmethylsilicone (PMS). Separations of volatile organics are investigated isothermally on duplicate sets of polyimide columns by GC with a flame ionization detector using split injection. Unlike the uncoated ones, the coated polyimide columns successfully separate Grob test mix classes of alkanes, amines, and fatty acid methyl esters. The relative standard deviations for retention time and peak area are 0.5 and 2.5 , respectively. With the 3 m PMS-coated column connected to a retention gap to permit operation at its optimum flow rate of 30 cm/s, a plate count of 3200 or plate height of 1 mm is possible. Lack of retention and tailing peaks are evident for the polyimide polymer capillary columns as compared to that of a 3 m commercial cross-linked PMS fused silica capillary. However, headspace analyses of an aromatic hydrocarbon mix and a Clearcoat automotive paint sample are viable applications on the PMS polyimide polymer column. PMID:21682994

  5. Novel Design for Centrifugal Countercurrent Chromatography: I. Zigzag Toroidal Column.

    PubMed

    Yang, Yi; Aisa, Haji Akber; Ito, Yoichiro

    2009-01-01

    The toroidal coil using an equilateral triangular core has improved both retention of the stationary phase and peak resolution of the conventional toroidal coil in centrifugal countercurrent chromatography. To further improve the retention of stationary phase and peak resolution, a novel zigzag toroidal coil was designed and the performance of the system was evaluated at various flow rates. The results indicated that both retention of stationary phase and peak resolution were improved as the flow rate was decreased. Modification of the tubing by pressing at given intervals with a pair of pliers improved the peak resolution without increasing the column pressure. All these separations were performed under low column pressure indicating the separation can be further improved by increasing the column length and/or revolution speed without damaging the separation column. PMID:20046954

  6. Evaluating two process scale chromatography column header designs using CFD.

    PubMed

    Johnson, Chris; Natarajan, Venkatesh; Antoniou, Chris

    2014-01-01

    Chromatography is an indispensable unit operation in the downstream processing of biomolecules. Scaling of chromatographic operations typically involves a significant increase in the column diameter. At this scale, the flow distribution within a packed bed could be severely affected by the distributor design in process scale columns. Different vendors offer process scale columns with varying design features. The effect of these design features on the flow distribution in packed beds and the resultant effect on column efficiency and cleanability needs to be properly understood in order to prevent unpleasant surprises on scale-up. Computational Fluid Dynamics (CFD) provides a cost-effective means to explore the effect of various distributor designs on process scale performance. In this work, we present a CFD tool that was developed and validated against experimental dye traces and tracer injections. Subsequently, the tool was employed to compare and contrast two commercially available header designs. PMID:24616438

  7. Modeling of crystal violet adsorption by bottom ash column.

    PubMed

    Nidheesh, P V; Gandhimathi, R; Ramesh, S T; Singh, T S Anantha

    2013-06-01

    The removal of crystal violet from wastewater, by means of bottom ash, was investigated in a packed bed down-flow column. The bed depth service time (BDST) model was used to analyze the experimental data up to breakthrough time (corresponding to C(t)/C(0) = 0.1). A mass transfer model was used to analyze the mass transfer zone. The breakthrough curve was analyzed by the Thomas, Yoon-Nelson, and Clark models. All models fit well with the experimental data. Results showed that as the flow rate increases, at a constant concentration and bed depth, the value of the adsorption capacity of bottom ash decreases. The adsorption capacity of bottom ash decreases with an increase in depth and initial crystal violet concentration. Error analyses were performed for the Thomas, Yoon-Nelson, and Clark models. Water PMID:23833812

  8. Optimization of preparative separation and purification of total polyphenols from Sargassum tenerrimum by column chromatography

    NASA Astrophysics Data System (ADS)

    Haider, Samee; Li, Zhenxing; Lin, Hong; Jamil, Khalid

    2009-12-01

    Polyphenols from the ethanol extracts of Sargassum tenerrimum (ST) with potent antiallergic effects were studied to optimize separation process through column chromatography. The adsorption and desorption characteristics of three widely used adsorbents: macroporous resin, silica gel, and polyvinylpolypyrrolidone (PVPP), were critically evaluated respectively and studied for the optimization of preparative separation of polyphenols. Static operations on these adsorbents showed that macroporous resin had the best adsorption and desorption capability among the three adsorbents. Dynamic adsorption and desorption with macroporous resin packed column were also conducted to optimize the parameters such as: with the optimal values shown in brackets, the concentration of extract solution (4 times diluted), pH value (6-7), adsorption speed (3 BV h-1, bed volumes/per hour), concentration of ethanol (80%), elution speed (3 BV h-1) and elution volume (7 BV). The chromatographic process so optimized gave a purity of 62.43% from the crude polyphenols, providing a promising basis for large scale preparation of bioactive polyphenols upon further scaling up tests.

  9. Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns.

    PubMed

    Jones, Andrew; Pravadali-Cekic, Sercan; Hua, Stanley; Kocic, Danijela; Camenzuli, Michelle; Dennis, Gary; Shalliker, Andrew

    2016-01-01

    A protocol for the use of reaction flow high performance liquid chromatography columns for methods employing post column derivatization (PCD) is presented. A major difficulty in adapting PCD to modern HPLC systems and columns is the need for large volume reaction coils that enable reagent mixing and then the derivatization reaction to take place. This large post column dead volume leads to band broadening, which results in a loss of observed separation efficiency and indeed detection in sensitivity. In reaction flow post column derivatization (RF-PCD) the derivatization reagent(s) are pumped against the flow of mobile phase into either one or two of the outer ports of the reaction flow column where it is mixed with column effluent inside a frit housed within the column end fitting. This technique allows for more efficient mixing of the column effluent and derivatization reagent(s) meaning that the volume of the reaction loops can be minimized or even eliminated altogether. It has been found that RF-PCD methods perform better than conventional PCD methods in terms of observed separation efficiency and signal to noise ratio. A further advantage of RF-PCD techniques is the ability to monitor effluent coming from the central port in its underivatized state. RF-PCD has currently been trialed on a relatively small range of post column reactions, however, there is currently no reason to suggest that RF-PCD could not be adapted to any existing one or two component (as long as both reagents are added at the same time) post column derivatization reaction. PMID:27168419

  10. Glycolipid class profiling by packed-column subcritical fluid chromatography.

    PubMed

    Deschamps, Frantz S; Lesellier, Eric; Bleton, Jean; Baillet, Arlette; Tchapla, Alain; Chaminade, Pierre

    2004-06-18

    The potential of packed-column subcritical fluid chromatography (SubFC) for the separation of lipid classes has been assessed in this study. Three polar stationary phases were checked: silica, diol, and poly(vinyl alcohol). Carbon dioxide (CO2) with methanol as modifier was used as mobile phase and detection performed by evaporative light scattering detection. The influence of methanol content, temperature, and pressure on the chromatographic behavior of sphingolipids and glycolipids were investigated. A complete separation of lipid classes from a crude wheat lipid extract was achieved using a modifier gradient from 10 to 40% methanol in carbon dioxide. Solute selectivity was improved using coupled silica and diol columns in series. Because the variation of eluotropic strength depending on the fluid density changes, a normalized separation factor product (NSP) was used to select the nature, the number and the order of the columns to reach the optimum glycolipid separation. PMID:15248431

  11. Direct probing of chromatography columns by laser-induced fluorescence

    SciTech Connect

    McGuffin, V.L.

    1992-12-07

    This report summarizes the progress and accomplishments of this research project from September 1, 1989 to February 28, 1993. During this period, we have accomplished all of the primary scientific objectives of the research proposal: (1) constructed and evaluated a laser-induced fluorescence detection system that allows direct examination of the chromatographic column, (2) examined nonequilibrium processes that occur upon solute injection and elution, (3) examined solute retention in liquid chromatography as a function of temperature and pressure, (4) examined solute zone dispersion in liquid chromatography as a function of temperature and pressure, and (5) developed appropriate theoretical models to describe these phenomena. In each of these studies, substantial knowledge has been gained of the fundamental processes that are responsible for chromatographic separations. In addition to these primary research objectives, we have made significant progress in three related areas: (1) examined pyrene as a fluorescent polarity probe insupercritical fluids and liquids as a function of temperature and pressure, (2) developed methods for the class-selective identification of polynuclear aromatic hydrocarbons in coal-derived fluids by microcolumn liquid chromatography with fluorescence quenching detection, and (3) developed methods for the determination of saturated and unsaturated (including omega-3) fatty acids in fish oil extracts by microcolumn liquid chromatography with laser-induced fluorescence detection. In these studies, the advanced separation and detection techniques developed in our laboratory are applied to practical problems of environmental and biomedical significance.

  12. Direct probing of chromatography columns by laser-induced fluorescence

    NASA Astrophysics Data System (ADS)

    McGuffin, V. L.

    1992-12-01

    This report summarizes the progress and accomplishments of this research project from 1 Sep. 1989 to 28 Feb. 1993. During this period, we have accomplished all of the primary scientific objectives of the research proposal: (1) constructed and evaluated a laser-induced fluorescence detection system that allows direct examination of the chromatographic column, (2) examined nonequilibrium processes that occur upon solute injection and elution, (3) examined solute retention in liquid chromatography as a function of temperature and pressure, (4) examined solute zone dispersion in liquid chromatography as a function of temperature and pressure, and (5) developed appropriate theoretical models to describe these phenomena. In each of these studies, substantial knowledge has been gained of the fundamental processes that are responsible for chromatographic separations. In addition to these primary research objectives, we have made significant progress in three related areas: (1) examined pyrene as a fluorescent polarity probe in supercritical fluids and liquids as a function of temperature and pressure, (2) developed methods for the class-selective identification of polynuclear aromatic hydrocarbons in coal-derived fluids by microcolumn liquid chromatography with fluorescence quenching detection, and (3) developed methods for the determination of saturated and unsaturated (including omega-3) fatty acids in fish oil extracts by microcolumn liquid chromatography with laser-induced fluorescence detection. In these studies, the advanced separation and detection techniques developed in our laboratory are applied to practical problems of environmental and biomedical significance.

  13. If You Were a Molecule in a Chromatography Column, What Would You See?

    ERIC Educational Resources Information Center

    Mattice, John

    2008-01-01

    To visualize what takes place in a chromatography column, enlarge the molecules to human size and expand the columns to keep the ratio of size of molecule to size of column the same. If we were molecules, what would the columns be like? A typical gas chromatography (GC) capillary column would be 50 x 10 [superscript 6] 6 km (31 million mi) long,…

  14. Group type analysis of asphalt by column liquid chromatography

    SciTech Connect

    Zhang, C.; Yang, J.; Xue, Y.; Li, Y.

    2008-07-01

    An improved analysis method for characterization of asphalt was established. The method is based on column chromatography technique. The asphalts were separated into four groups: saturates, aromatics, resins, and asphaltenes, quantitatively. About 0.1 g of sample was required in each analysis. About 20 mL of n-heptanes was used to separate out saturates first. Then about 35 mL of n-heptanes/dichloromethane (.5, v/v) mixture was used to separate out aromatics. About 30 mL of dichloromethane/tetrahydrofuran (1/3, v/v) mixture was used to separate out resin. The quality of the separation was confirmed by infrared spectra (IR) and {sup 1}H NMR analysis. The model compounds, tetracosan for saturates, dibenz(o)anthracen for aromatics, and acetanilide for resins were used for verification. The IR and {sup 1}H NMR analysis of the prepared fractions from the column liquid chromatography were in good agreement that of pure reagents.

  15. Methodology for optimally sized centrifugal partition chromatography columns.

    PubMed

    Chollet, Sébastien; Marchal, Luc; Jérémy Meucci; Renault, Jean-Hugues; Legrand, Jack; Foucault, Alain

    2015-04-01

    Centrifugal Partition Chromatography (CPC) is a separation process based on the partitioning of solutes between two partially miscible liquid phases. There is no solid support for the stationary phase. The centrifugal acceleration is responsible for both stationary phase retention and mobile phase dispersion. CPC is thus a process based on liquid-liquid mass transfer. The separation efficiency is mainly influenced by the hydrodynamics of the phases in each cell of the column. Thanks to a visualization system, called "Visual CPC", it was observed that the mobile phase can flow through the stationary phase as a sheet, or a spray. Hydrodynamics, which directly governs the instrument efficiency, is directly affected during scale changes, and non-linear phenomena prevent the successful achievement of mastered geometrical scale changes. In this work, a methodology for CPC column sizing is proposed, based on the characterization of the efficiency of advanced cell shapes, taking into account the hydrodynamics. Knowledge about relationship between stationary phase volume, cell efficiency and separation resolution in CPC allowed calculating the optimum cell number for laboratory and industrial scale CPC application. The methodology is highlighted with results on five different geometries from 25 to 5000 mL, for two applications: the separation of alkylbenzene by partitioning with heptane/methanol/water biphasic system; and the separation of peptides by partitioning with n-butanol/acetic acid/water (4/1/5) biphasic system. With this approach, it is possible to predict the optimal CPC column length leading to highest productivity. PMID:25744547

  16. Effects of Humidity Swings on Adsorption Columns for Air Revitalization: Modeling and Experiments

    NASA Technical Reports Server (NTRS)

    LeVan, M. Douglas; Finn, John E.

    1997-01-01

    Air purification systems are necessary to provide clean air in the closed environments aboard spacecraft. Trace contaminants are removed using adsorption. One major factor concerning the removal of trace contaminants is relative humidity. Water can reduce adsorption capacity and, due to constant fluctuations, its presence is difficult to incorporate into adsorption column designs. The purpose of the research was to allow for better design techniques in trace contaminant adsorption systems, especially for feeds with water present. Experiments and mathematical modeling research on effects of humidity swings on adsorption columns for air revitalization were carried out.

  17. Colorful Column Chromatography: A Classroom Demonstration of a Three-Component Separation

    NASA Astrophysics Data System (ADS)

    Heumann, Lars V.

    2008-04-01

    A classroom demonstration detailing the procedure for the separation of a ternary mixture consisting of intensely colored compounds using silica gel column chromatography is described. The audience can follow the compounds during their passage through the column as individual, colored bands while learning about different tools and techniques used in conjunction with column chromatography. Detailed instructions for column preparation and the elution and collection process are provided and permit the easy replication of this demonstration.

  18. Isolation of Three Components from Spearmint Oil: An Exercise in Column and Thin-Layer Chromatography

    ERIC Educational Resources Information Center

    Davies, Don R.; Johnson, Todd M.

    2007-01-01

    A simple experiment for undergraduate organic chemistry students to separate a colorless mixture using column chromatography and then monitor the outcome of the separation using thin-layer chromatography (TLC) and infrared spectroscopy(IR) is described. The experiment teaches students the principle and techniques of column and thin-layer…

  19. A Continuous Procedure Based on Column Chromatography to Purify Anthocyanins from Schisandra chinensis by a Macroporous Resin plus Gel Filtration Chromatography.

    PubMed

    Yue, Daran; Yang, Lei; Liu, Shouxin; Li, Jian; Li, Wei; Ma, Chunhui

    2016-01-01

    In our previous study, as natural food colorants and antioxidants, the color and content stabilities of Schisandra chinensis (S. chinensis) anthocyanins were investigated. In this work, the purification process parameters of S. chinensis anthocyanins using a macroporous resin and gel filtration chromatography were evaluated. The optimized parameters of static adsorption and desorption were as follows. The selected resin is HPD-300 (nonpolar copolymer styrene type resin), and the anthocyanins adsorption saturation capacity of HPD-300 resin was 0.475 mg/g dry resin. Adsorption time was 4 h, and 0.517 mg/mL of S. chinensis anthocyanins was adsorbed on the resin column with a flow rate of 39 mL/h (3 BV/h). After adsorption, the anthocyanins were completely desorpted with 2.5 BV of 90% (v/v) ethanol solution, and the desorption flow rate was 13 mL/h (1 BV/h). After purification by dynamic adsorption and desorption, the anthocyanins content in the effluent increased from 47.6 mg/g to 128.4 mg/g, the purity of anthocyanins increased six-fold from 5.08% to 30.43%, and the anthocyanins recovery was 96.5%. The major constituent of S. chinensis anthocyanins was isolated with Bio-Gel P2 gel filtration chromatography, and it was detected by liquid chromatography electrospray ionisation tandem mass spectrometry (LC-ESI-MS) as cyanidin-3-O-xylosylrutinoside. Moreover, the antioxidant activities of S. chinensis anthocyanins were investigated. After purification using the HPD-300 resin, the antioxidant activities of anthocyanins were increased 1.2-fold (FRAP) and 1.7-fold (ABTS). PMID:26861279

  20. Cellufine sulfate column chromatography as a simple, rapid, and effective method to purify dengue virus.

    PubMed

    Kanlaya, Rattiyaporn; Thongboonkerd, Visith

    2016-08-01

    Conventional method to purify/concentrate dengue virus (DENV) is time-consuming with low virus recovery yield. Herein, we applied cellufine sulfate column chromatography to purify/concentrate DENV based on the mimicry between heparan sulfate and DENV envelope protein. Comparative analysis demonstrated that this new method offered higher purity (as determined by less contamination of bovine serum albumin) and recovery yield (as determined by greater infectivity). Moreover, overall duration used for cellufine sulfate column chromatography to purify/concentrate DENV was approximately 1/20 of that of conventional method. Therefore, cellufine sulfate column chromatography serves as a simple, rapid, and effective alternative method for DENV purification/concentration. PMID:27155240

  1. PRECISION AND ACCURACY IN THE DETERMINATION OF ORGANICS IN WATER BY FUSED SILICA CAPILLARY COLUMN GAS CHROMOTOGRAPHY/MASS SPECTROMETRY AND PACKED COLUMN GAS CHROMATOGRAPHY/MASS SPECTROMETRY

    EPA Science Inventory

    Two general methods for the identification and measurement of organic compounds in water are compared. One method employs packed column chromatography and the other fused silica capillary column chromatography. The two gas chromatography/mass spectrometry (GC/MS) methods use diff...

  2. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of chlorinated pesticides in aquatic tissue by capillary-column gas chromatography with electron-capture detection

    USGS Publications Warehouse

    Leiker, Thomas J.; Madsen, J.E.; Deacon, J.R.; Foreman, W.T.

    1995-01-01

    A method for the determination of chlorinated organic compounds in aquatic tissue by dual capillary-column gas chromatography with electron-capture detection is described. Whole-body-fish or corbicula tissue is homogenized, Soxhlet extracted, lipid removed by gel permeation chromatography, and fractionated using alumina/silica adsorption chromatography. The extracts are analyzed by dissimilar capillary-column gas chromatography with electron-capture detection. The method reporting limits are 5 micrograms per kilogram (μg/kg) for chlorinated compounds, 50 μg/kg for polychlorinated biphenyls, and 200 μg/kg for toxaphene.

  3. Planar gas chromatography column on glass plate with nanodispersed silica as the stationary phase

    NASA Astrophysics Data System (ADS)

    Platonov, I. A.; Platonov, V. I.; Pavelyev, V. S.; Agafonov, A. N.

    2016-04-01

    The paper presents the GC column in the plane of the glass plate with the adsorption layer nanodispersed silica. Created gas chromatographic column allows to separate a mixture of five alkanes from pentane to nonane in isothermal (90 ° C) mode less than one minute.

  4. The development of an evaluation method for capture columns used in two-dimensional liquid chromatography.

    PubMed

    Cao, Liwei; Yu, Danhua; Wang, Xinliang; Ke, Yanxiong; Jin, Yu; Liang, Xinmiao

    2011-11-01

    Capture columns are important interface tools for on line two-dimensional liquid chromatography (2D-LC). In this study, a systematic method was developed to evaluate and optimize the capture ability of capture columns by off-line method. First, the parameter Δt(R) (Δt(R)=t(2)-t(1)-t(0)-W) was introduced to quantitatively represent the capture ability of the capture column by connecting a capture column behind the first dimensional column. Based on the value of Δt(R), an appropriate capture column was selected after the first dimensional column was fixed. Then, the capture ability of the selected column was promoted by adjusting the mobile phase of the first dimensional column. Capture ability was also optimized using complex sample analysis software system (CSASS) software. Second, the elution mode of the trapped compounds on the capture column was investigated by connecting the capture column before the second dimensional column. More specifically, in mode I, capture column was connected to the second dimension without changing the flow rate direction and the trapped compounds must pass through the capture column and be eluted into the second dimensional column. The contrary connection mode was mode II. It was found that mode I is more suitable method for 2D-LC. Finally, an off-line reversed-phase/hydrophilic interaction liquid chromatography two-dimensional liquid chromatography (RP/HILIC 2D-LC) system with a C18 capture column was developed to demonstrate the practical application of this method. PMID:21995927

  5. Pressure-dependent boron isotopic fractionation observed by column chromatography

    NASA Astrophysics Data System (ADS)

    Musashi, M.; Oi, T.; Matsuo, M.; Nomura, M.

    2007-12-01

    Boron isotopic fractionation factor ( S ) between boron taken up in strongly basic anion exchange resin and boron in aqueous solution was determined by breakthrough column chromatography at 5 and 17 MPa at 25°C, using 0.1 mmol/L boric acid solution as feed solution. The S values obtained were 1.018 and 1.012, respectively, which were smaller than the value reported by using the same chromatographic method at atmospheric pressure at 25°C with the boron concentration of 10 mmol/L, but were larger than the values at the same condition with much higher concentration of 100 and 501 mmol/L, indicating that borate-polymerization reducing the isotopic fractionation was negligible. However, calculations based on the theory of isotope distribution between two phases estimated that 21% (5MPa) and 47% (17MPa) of boron taken up in the resin phase was in the three-coordinated B(OH)3-form, instead of in the four-coordinated B(OH)4--form, at high pressures even with the very diluted solution. We discussed this discrepancy by introducing (1) hydration or (2) a partial molar volume difference between isotopic molecules. It was inferred that borate ions were partially dehydrated upon transfer from the solution phase to the resin phase at high pressures, which resulted in smaller S values compared with those at the atmospheric pressure. Alternatively, it was likely that the S value decreased with increasing pressure, because the difference of the partial isotopic molar volumes between 10B(OH)3 and 11B(OH)3 was larger than that between 10B(OH)4- and 11B(OH)4-. If either will be the case, the influence of a pressure upon the isotope effect may not be negligible for boron isotopic exchange equilibrium. This knowledge is crucial for the principle of the boron isotopic pH-metry reconstructing a chemical variation at the paleo-deep oceanic environment where the early life may have been evolved.

  6. Colorful Column Chromatography: A Classroom Demonstration of a Three-Component Separation

    ERIC Educational Resources Information Center

    Heumann, Lars V.

    2008-01-01

    A classroom demonstration detailing the procedure for the separation of a ternary mixture consisting of intensely colored compounds using silica gel column chromatography is described. The audience can follow the compounds during their passage through the column as individual, colored bands while learning about different tools and techniques used…

  7. Determining the Influence of Groundwater Composition on the Performance of Arsenic Adsorption Columns Using Rapid Small-Scale Column Tests

    NASA Astrophysics Data System (ADS)

    Aragon, A. R.; Siegel, M.

    2004-12-01

    The USEPA has established a more stringent drinking water standard for arsenic, reducing the maximum contaminant level (MCL) from 50 μ g/L to 10 μ g/L. This will affect many small communities in the US that lack the appropriate treatment infrastructure and funding to reduce arsenic to such levels. For such communities, adsorption systems are the preferred technology based on ease of operation and relatively lower costs. The performance of adsorption media for the removal of arsenic from drinking water is dependent on site-specific water quality. At certain concentrations, co-occurring solutes will compete effectively with arsenic for sorption sites, potentially reducing the sorption capacity of the media. Due to the site-specific nature of water quality and variations in media properties, pilot scale studies are typically carried out to ensure that a proposed treatment technique is cost effective before installation of a full-scale system. Sandia National Laboratories is currently developing an approach to utilize rapid small-scale columns in lieu of pilot columns to test innovative technologies that could significantly reduce the cost of treatment in small communities. Rapid small-scale column tests (RSSCTs) were developed to predict full-scale treatment of organic contaminants by adsorption onto granular activated carbon (GAC). This process greatly reduced the time and costs required to verify performance of GAC adsorption columns. In this study, the RSSCT methodology is used to predict the removal of inorganic arsenic using mixed metal oxyhydroxide adsorption media. The media are engineered and synthesized from materials that control arsenic behavior in natural and disturbed systems. We describe the underlying theory and application of RSSCTs for the performance evaluation of novel media in several groundwater compositions. Results of small-scale laboratory columns are being used to predict the performance of pilot-scale systems and ultimately to design full

  8. Novel Designs for Centrifugal Countercurrent chromatography: V. Comparative Studies on Performance of Various Column Configurations.

    PubMed

    Yang, Yi; Gu, Dongyu; Aisa, Haji Akber; Ito, Yoichiro

    2010-01-01

    The conventional toroidal coil in centrifugal countercurrent chromatography has a low level of stationary phase retention, since a half of each helical turn is entirely occupied by the mobile phase. In order to cope with this problem, several new column designs including zigzag, saw-tooth and figure-8 patterns have been introduced and their performance was compared in terms of retention of the stationary phase (Sf), peak resolution (Rs), theoretical plate number (N) and column pressures. Overall results of experiments indicate that the figure-8 column yields the highest Rs when the lower phase is used as the mobile phase. Since the column pressure of all these new columns are much lower than that in the traditional toroidal coil column, the separation efficiency can be improved using a long separation column without a risk of column damage by high back pressure. PMID:21057664

  9. New Method for Evaluating Irreversible Adsorption and Stationary Phase Bleed in Gas Chromatographic Capillary Columns

    SciTech Connect

    Wright, Bob W.; Wright, Cherylyn W.

    2012-10-26

    A novel method for the evaluation of gas chromatographic (GC) column inertness has been developed using a tandem GC approach. Typically column inertness is measured by analyte peak shape evaluation. In general, silica, glass, and metal surfaces are chemically reactive and can cause analyte adsorption, which typically is observed as chromatographic peak tailing. Adsorption processes produce broad, short chromatographic peaks that confound peak area determinations because a significant portion can reside in the noise. In addition, chromatographic surfaces and stationary phases can irreversibly adsorb certain analytes without obvious degradation of peak shape. The inertness measurements described in this work specifically determine the degree of irreversible adsorption behavior of specific target compounds at levels ranging from approximately 50 picograms to 1 nanogram on selected gas chromatographic columns. Chromatographic columns with 5% phenylmethylsiloxane, polyethylene glycol (wax), trifluoropropylsiloxane, and 78% cyanopropylsiloxane stationary phases were evaluated with a variety of phosphorus- and sulfur- containing compounds selected as test compounds due to their ease of adsorption and importance in trace analytical detection. In addition, the method was shown effective for characterizing column bleed.

  10. Modeling and fixed bed column adsorption of As(V) on laterite soil.

    PubMed

    Maji, Sanjoy K; Pal, Anjali; Pal, Tarasankar; Adak, Asok

    2007-09-01

    Laterite soil, an abundant locally available natural adsorbent, has been evaluated for As(V) removal from aqueous solutions in column mode operation. The column studies were conducted using columns of 10, 20, 30 cm bed depth with 2 cm internal diameter. Initial As(V) concentration was 0.5 mg/L and flow rate was 7.75 mL/min. Bohart and Adams sorption model was employed for the determination of different parameters like height of exchange zone, adsorption rate, time required for exchange zone to move, and the adsorption capacity. Effect of flow rate and initial concentration was studied. The adsorption capacity of the laterite soil for 0.5 mg/L of As(V) was found to be 62.32 mg/L, and the adsorption rate constant was 1.0911 L/mg h for the minimum bed depth of 8.47 cm. The column was designed by the BDST model. Freundlich isotherm model was used to compare the theoretical and experimental breakthrough profile in the dynamic process. The bed saturation obtained was 36-80%. Regeneration of the exhausted column was possible with 1M NaOH. PMID:17849300

  11. Stationary phase modulation in liquid chromatography through the serial coupling of columns: A review.

    PubMed

    Alvarez-Segura, T; Torres-Lapasió, J R; Ortiz-Bolsico, C; García-Alvarez-Coque, M C

    2016-06-01

    Liquid chromatography with single columns often does not succeed in the analysis of complex samples, in terms of resolution and analysis time. A relatively simple solution to enhance chromatographic resolution is the modulation of the stationary phase through the serial coupling of columns. This can be implemented with any type of column using compatible elution conditions and conventional instruments. This review describes the key features of column coupling and published procedures, where two or more columns were coupled in series to solve separation problems. In all reports, the authors could not resolve their samples with single columns, whereas significant enhancement in chromatographic performance was obtained when the columns were combined. Particularly interesting is the reduction in the analysis time in the isocratic mode, which alleviates the "general elution problem" of liquid chromatography, and may represent a stimulus for the proposal of new procedures, especially in combination with mass spectrometric, electrochemical and refractometric detection. Developments proposed to make the serial coupling of columns useful in routine and research laboratories are outlined, including optimisation strategies that facilitate the selection of the appropriate column combination and elution conditions (solvent content, flow rate or temperature) in both isocratic and gradient modes. The availability of zero dead volume couplers, able to connect standard columns, and the commercialisation of short columns with multiple lengths, have expanded the possibilities of success. PMID:27155298

  12. Efficiency of supercritical fluid chromatography columns in different thermal environments.

    PubMed

    Kaczmarski, Krzysztof; Poe, Donald P; Tarafder, Abhijit; Guiochon, Georges

    2013-05-24

    The efficiency of a packed column eluted with supercritical carbon dioxide at 323K and outlet pressures from 90 to 150bar was studied with the column in two different thermal environments. The 150mm×2.0mm ID stainless steel column was packed with spherical 5-μm porous silica particles with a covalently bonded nonpolar stationary phase, and the test solutes were normal alkanes. When operated in a convective air bath the column exhibited severe efficiency losses when its outlet pressure was below 120bar. The efficiency of the same column enclosed in a shell made of foam insulation was restored at low outlet pressures down to 100bar. The van Deemter plots showed an abnormal dependence of the plate height (HETP) on the flow rate at low outlet pressures, exhibiting a maximum in the HETP at flow rates around 1mL/min and a 20-bar pressure drop. The large efficiency losses at low outlet pressures are due to radial temperature gradients associated with enthalpic expansion and cooling of the mobile phase. The separations were simulated by a numerical model that accounts for axial and radial gradients in the temperature and density along the column. The abnormal van Deemter plots arise from competing processes affecting the radial distribution of the solute migration velocity along the column. The negative impact on efficiency is greatest when the density profile of the mobile phase along the column is close to the critical isopycnic line. The efficiency improves at increased flow rates because of increased cooling at larger pressure drops and increased density along the entire length of the column. The model predicts the unusual trends in the van Deemter plots, but the calculated results at low outlet pressures are strongly influenced by small variations in the porosity distribution in the column, limiting the accuracy of the predicted HETP values. In spite of these difficulties, the model has enabled a detailed analysis of the effects of temperature, pressure and flow

  13. Generator for ionic gallium-68 based on column chromatography

    DOEpatents

    Neirinckx, Rudi D.; Davis, Michael A.

    1981-01-01

    A physiologically acceptable solution of gallium-68 fluorides, having an activity of 0.1 to 50 millicuries per milliliter of solution is provided. The solution is obtained from a generator comprising germanium-68 hexafluoride bound to a column of an anion exchange resin which forms gallium-68 in situ by eluting the column with an acid solution to form a solution containing .sup.68 Ga-fluorides. The solution then is neutralized prior to administration.

  14. Orthogonal separation on one beta-cyclodextrin column by switching reversed-phase liquid chromatography and hydrophilic interaction chromatography.

    PubMed

    Feng, Jia-tao; Guo, Zhi-mou; Shi, Hui; Gu, Jiang-ping; Jin, Yu; Liang, Xin-miao

    2010-06-15

    A dual retention combined with reversed-phase liquid chromatography (RP-LC) and hydrophilic interaction chromatography (HILIC) has been observed on beta-cyclodextrin (beta-CD) bonded stationary phase. A typical U-shaped retention curve was achieved owing to dual retention mechanism. Based on this observation, a beta-CD column can be operated under reversed-phase liquid chromatography (RP-LC) and hydrophilic interaction chromatography (HILIC) modes. Two-dimensional liquid chromatography (2D-LC) analysis can be realized on just a beta-CD column by switching these two different separation modes. In this study, off-line 2D-LC analysis for a natural product was carried out to prove the orthogonal separation between RP-LC and HILIC modes on a Click beta-CD column. Herba Hedyotis Diffusae, the whole grass of Hedyotis Diffusae wild was extracted with water, pretreated with macroporous resin and then first separated at RP-LC mode on the Click beta-CD column to obtain successive fractions, which were then reanalyzed at HILIC mode on the same Click beta-CD column. The result proved that both separation modes on the Click beta-CD column have good retention and peak shape, and these two separation modes have good orthogonality. 2D-LC analysis revealed abundant information in the natural product. Especially numerous minor components were enriched and separated. The mobile phase used in RP-LC and HILIC modes can be same and the switch between these two separation modes is easily realized by changing the ratio of the acetonitrile and water. Hence the mobile phase in this 2D-LC system is completely compatible. This advantage makes this combination is an appropriate 2D-LC method for the solutes having retention at both separation modes. PMID:20441989

  15. Preparing titania aerogel monolithic chromatography columns using supercritical carbon dioxide.

    PubMed

    Sui, Ruohong; Liu, Suya; Lajoie, Gilles A; Charpentier, Paul A

    2010-06-01

    The search for a method to fabricate monolithic inorganic columns has attracted significant recent attention due to their unique ability in separation applications of various biomolecules. Silica and polymer based monolithic columns have been prepared, but titania and other metal oxide monoliths have been elusive, primarily due to their fragility. This article describes a new approach for preparing nanostructured titania based columns, which offer better performance over conventional particle packed columns for separating a wide variety of biomolecules including phosphopeptides. TiO(2) monolithic aerogels were synthesized in separation columns using in situ sol-gel reactions in supercritical carbon dioxide (scCO(2)) followed by calcination, and compared to those prepared in heptanes. The characterization results show that scCO(2) is a better solvent for the sol-gel reactions, providing lower shrinkage with the anatase TiO(2) monolith composed of nanofibers with very high surface areas. The monolithic columns show the ability to isolate phosphopeptides with little flow resistance compared to conventional titania particle based microcolumns. PMID:20373296

  16. Novel highly hydrophilic zwitterionic monolithic column for hydrophilic interaction chromatography.

    PubMed

    Jiang, Zhengjin; Smith, Norman W; Ferguson, Paul D; Taylor, Mark R

    2009-08-01

    A novel zwitterionic hydrophilic porous poly(SPV-co-MBA) monolithic column was prepared by thermal co-polymerisation of 1-(3-sulphopropyl)-4-vinylpyridinium-betaine (4-SPV) and N,N'-methylenebisacrylamide (MBA). An HILIC/RP dual separation mechanism was observed on this optimised poly(SPV-co-MBA) monolithic column and the composition of the mobile phase corresponding to the transition from the HILIC to the RP mode was around 30% ACN in water. Higher hydrophilicity was achieved on this novel monolithic column compared to the poly(N,N-dimethyl-N-methacryloxyethyl-N-(3-sulphopropyl)ammonium betaine-co-ethylene dimethacrylate) monolithic column. Permeability studies showed slight swelling and/or shrinking with mobile phases of different polarity. As might be anticipated, a weak electrostatic interaction for charged analytes was also observed by studying the influence of mobile phase pH and salt concentration on their retention on the poly(SPV-co-MBA) monolithic column. The final optimised poly(SPV-co-MBA) monolith showed comparable selectivities to commercial ZIC-pHILIC phases for polar test analytes. Fast separation of five pyrimidines and purines was achieved in less than 1 min due to the high permeability of the monolithic column. Additionally, baseline separation of nine benzoic acid derivatives was also observed using either a pH or ACN gradient. PMID:19606441

  17. Preparation and Characterization of a Polymeric Monolithic Column for Use in High-Performance Liquid Chromatography (HPLC)

    ERIC Educational Resources Information Center

    Bindis, Michael P.; Bretz, Stacey Lowery; Danielson, Neil D.

    2011-01-01

    The high-performance liquid chromatography (HPLC) experiment, most often done in the undergraduate analytical instrumentation laboratory course, generally illustrates reversed-phase chromatography using a commercial C[subscript]18 silica column. To avoid the expense of periodic column replacement and introduce a choice of columns with different…

  18. Sum of ranking differences to rank stationary phases used in packed column supercritical fluid chromatography.

    PubMed

    West, Caroline; Khalikova, Maria A; Lesellier, Eric; Héberger, Károly

    2015-08-28

    The identification of a suitable stationary phase in supercritical fluid chromatography (SFC) is a major source of difficulty for those with little experience in this technique. Several protocols have been suggested for column classification in high-performance liquid chromatography (HPLC), gas chromatography (GC), and SFC. However, none of the proposed classification schemes received general acceptance. A fair way to compare columns was proposed with the sum of ranking differences (SRD). In this project, we used the retention data obtained for 86 test compounds with varied polarity and structure, analyzed on 71 different stationary phases encompassing the full range in polarity of commercial packed columns currently available to the SFC chromatographer, with a single set of mobile phase and operating conditions (carbon dioxide-methanol mobile phase, 25°C, 150bar outlet pressure, 3ml/min). First, a reference column was selected and the 70 remaining columns were ranked based on this reference column and the retention data obtained on the 86 analytes. As these analytes previously served for the calculation of linear solvation energy relationships (LSER) on the 71 columns, SRD ranks were compared to LSER methodology. Finally, an external comparison based on the analysis of 10 other analytes (UV filters) related the observed selectivity to SRD ranking. Comparison of elution orders of the UV filters to the SRD rankings is highly supportive of the adequacy of SRD methodology to select similar and dissimilar columns. PMID:26228853

  19. Assessing Arsenic Removal by Metal (Hydr)Oxide Adsorptive Media Using Rapid Small Scale Column Tests

    EPA Science Inventory

    The rapid small scale column test (RSSCT) was use to evaluate the the performance of eight commercially available adsorptive media for the removal of arsenic. Side-by-side tests were conducted using RSSCTs and pilot/full-scale systems either in the field or in the laboratory. ...

  20. Highly crosslinked silicon polymers for gas chromatography columns

    NASA Technical Reports Server (NTRS)

    Shen, Thomas C. (Inventor)

    1994-01-01

    A new highly crosslinked silicone polymer particle for gas chromatography application and a process for synthesizing such copolymer are described. The new copolymer comprises vinyltriethoxysilane and octadecyltrichlorosilane. The copolymer has a high degree of crosslinking and a cool balance of polar to nonpolar sites in the porous silicon polymer assuring fast separation of compounds of variable polarity.

  1. Developing Inquiry-Based Labs Using Micro-Column Chromatography

    ERIC Educational Resources Information Center

    Barden-Gabbei, Laura M.; Moffitt, Deborah L.

    2006-01-01

    Chromatography is a process by which mixtures can be separated or substances can be purified. Biological and chemical laboratories use many different types of chromatographic processes. For example, the pharmaceutical industry uses chromatographic techniques to purify drugs, medical labs use them to identify blood components such as cholesterol,…

  2. Blocking effect of colloids on arsenate adsorption during co-transport through saturated sand columns.

    PubMed

    Ma, Jie; Guo, Huaming; Lei, Mei; Wan, Xiaoming; Zhang, Hanzhi; Feng, Xiaojuan; Wei, Rongfei; Tian, Liyan; Han, Xiaokun

    2016-06-01

    Transport of environmental pollutants through porous media is influenced by colloids. Co-transport of As(V) and soil colloids at different pH were systematically investigated by monitoring breakthrough curves (BTCs) in saturated sand columns. A solute transport model was applied to characterize transport and retention sites of As(V) in saturated sand in the presence of soil colloids. A colloid transport model and the DLVO theory were used to reveal the mechanism and hypothesis of soil colloid-promoted As(V) transport in the columns. Results showed that rapid transport of soil colloids, regulated by pH and ionic strength, promoted As(V) transport by blocking As(V) adsorption onto sand, although soil colloids had low adsorption for As(V). The promoted transport was more significant at higher concentrations of soil colloids (between 25 mg L(-1) and 150 mg L(-1)) due to greater blocking effect on As(V) adsorption onto the sand surfaces. The blocking effect of colloids was explained by the decreases in both instantaneous (equilibrium) As adsorption and first-order kinetic As adsorption on the sand surface sites. The discovery of this blocking effect improves our understanding of colloid-promoted As transport in saturated porous media, which provides new insights into role of colloids, especially colloids with low As adsorption capacity, in As transport and mobilization in soil-groundwater systems. PMID:27017140

  3. [Determination of organic residues in macroporous adsorption resins by gas chromatography].

    PubMed

    Jia, Cunqin; Li, Yangchun; Tu, Pengfei; Zhang, Hongquan

    2005-11-01

    A method has been developed for the simultaneous determination of benzene, toluene, xylene, styrene, decane, diethylbenzene, undecane, divinylbenzene, dodecane and naphthalene residues in macroporous adsorption resins (MARs). The organic residues were extracted from resin samples by ultrasonic extraction with dichloromethane and analyzed by gas chromatography. The chromatographic conditions were as follows: a DB-624 capillary column (30 m x 0.32 mm i.d., 1.8 microm); carrier gas, nitrogen with a flow rate of 2.5 mL/min; column temperature, programmed from 40 degrees C to 200 degrees C at a rate of 14 degrees C /min and kept at 200 degrees C for 1 min; flame ionization detector temperature, 250 degrees C; injector temperature, 220 degrees C; splitless injection, 1 microL. All the 10 organic residues were separated well in 12 min. The recoveries for spiked standards (n = 3) were 73.8% - 107.9%. The relative standard deviations were 1.3% - 4.4%. The limits of detection were 0.007 - 0.03 mg/L. This method is sensitive, accurate and quick. Nine commercial MARs and their pretreated samples were assayed, and the results show that the contents of organic residues varied greatly in two kinds of samples. And the pretreated MARs can be used safely in the production of traditional Chinese medicines. PMID:16499000

  4. Robust naphthyl methacrylate monolithic column for high performance liquid chromatography of a wide range of solutes.

    PubMed

    Jonnada, Murthy; El Rassi, Ziad

    2015-08-28

    An organic monolithic column based on the co-polymerization of 2-naphthyl methacrylate (NAPM) as the functional monomer and trimethylolpropane trimethacrylate (TRIM) as the crosslinker was introduced for high performance reversed-phase liquid chromatography (RPC). The co-polymerization was performed in situ in a stainless steel column of 4.6mm i.d. in the presence of a ternary porogen consisting of 1-dodecanol and cyclohexanol. This monolithic column (referred to as naphthyl methacrylate monolithic column or NMM column) showed high mechanical stability at relatively high mobile phase flow velocity indicating that the column has excellent hydrodynamic characteristics. To characterize the NMM column, different probe molecules including alkyl benzenes, and aniline, benzene, toluene and phenol derivatives were chromatographed on the column and the results in terms of k, selectivity and plate counts were compared to those obtained on an octadecyl silica (ODS) column in order to assess the presence of π-π and hydrophobic interactions on the NMM column under otherwise the same elution conditions. The NMM column offered additional π-π interactions with aromatic molecules in addition to hydrophobic interactions under RPC elution conditions. Run-to-run and column-to-column reproducibility of solute k values were evaluated, and percent relative standard deviation of <1% and ∼2-3.5%, respectively, were obtained. Six standard proteins were readily separated on the NMM column using shallow (30min at 1.0mL/min), steep (10min at 1.0mL/min) and ultra steep (1min at 3.0mL/min) linear gradient elution at increasing ACN concentration in the mobile phase using a 10cm×4.6mm i.d. column in case of shallow and steep linear gradients and a 3cm×4.6mm i.d. column for ultra steep linear gradient. PMID:26228852

  5. Twin-column CaptureSMB: a novel cyclic process for protein A affinity chromatography.

    PubMed

    Angarita, Monica; Müller-Späth, Thomas; Baur, Daniel; Lievrouw, Roel; Lissens, Geert; Morbidelli, Massimo

    2015-04-10

    A twin-column counter-current chromatography processes, CaptureSMB, was used for the protein A affinity capture of a monoclonal antibody (mAb). By means of sequential loading, the process improves the utilization of the stationary phase by achieving loadings much closer to the static binding capacity of the resin in comparison to batch chromatography. Using a mAb capture case study with protein A affinity chromatography, the performance and product quality obtained from CaptureSMB and batch processes were compared. The effect of the flow rate, column length and titer concentration on the process performance and product quality were evaluated. CaptureSMB showed superior performance compared to batch chromatography with respect to productivity, capacity utilization, product concentration and buffer consumption. A simplified economic evaluation showed that CaptureSMB could decrease resin costs of 10-30% depending on the manufacturing scenario. PMID:25748537

  6. Preparative separation of gallocatechin gallate from Camellia ptilophylla using macroporous resins followed by sephadex LH-20 column chromatography.

    PubMed

    Li, Kaikai; Zhou, Xuelin; Liu, Cheuk-Lun; Yang, Xiaorong; Han, Xiaoqiang; Shi, Xianggang; Song, Xiaohong; Ye, Chuangxing; Ko, Chun-hay

    2016-02-01

    Gallocatechin gallate (GCG) possesses multiple potential biological activities. However, the content of GCG in traditional green tea is too low which limits its in-depth pharmacological research and application. In the present study, a simple, efficient and environment-friendly chromatographic separation method was developed for preparative enrichment and separation of GCG from cocoa tea (Camellia ptilophylla) which contains high content of GCG. In the first step, the adsorption properties of selected resins were evaluated, and XAD-7HP resin was chosen by its adsorption and desorption properties for GCG. In order to maximize column efficiency for GCG collection, the operating parameters (e.g., flow rate, ethanol concentration, and bed height) were optimized. We found that the best combination was the feed concentration at 20mg/mL, flow rate at 0.75 BV/h and the ratio of diameter to bed heights as 1:12. Under these conditions, the purity of GCG was 45% with a recovery of 89%. In order to obtain pure target, a second step was established using column chromatography with sephadex LH-20 gel and 55% ethanol-water solution as eluent. After this step, the purity of the GCG was 91% with a recovery of 68% finally. PMID:26744789

  7. Chromatographic behavior of 12 polar pteridines in hydrophilic interaction chromatography using five different HILIC columns coupled with tandem mass spectrometry.

    PubMed

    Xiong, Xin; Liu, Yanmeng

    2016-04-01

    Retention characteristic of 5 hydrophilic interaction chromatography (HILIC) columns, containing neutral and possibly negatively charged support (silica, diol and amide), cationic phase (triazole) and zwitterionic phase (sulfobetaine), that are commercially available were studied for the separation of a group of 12 polar pteridines. The main factors influencing the retention and selectivity of pteridines for these different HILIC systems have been studied in liquid chromatography-tandem mass spectrometry (LC-MS/MS) conditions: mobile phase composition, buffer type, pH and concentration and the separation mechanism was also investigated. Results of the effects of organic modifier, buffer pH and ion strength indicate that the retention mechanism is a mixed-mode of adsorption and ion exchange, and optimization of HILIC analyses depends on the ionization state of the analytes. For silica, diol, amide and sulfobetaine phases, hydrophilic partitioning mainly contributes to the retention, while electrostatic interactions and hydrogen-bonding should be considered to understand the elution orders for triazole phase. An zwitterionic phase (ZIC-HILIC) provided the stronger retention for all pteridines than other tested columns. PMID:26838435

  8. Improved micromachined column design and fluidic interconnects for programmed high-temperature gas chromatography separations.

    PubMed

    Gaddes, David; Westland, Jessica; Dorman, Frank L; Tadigadapa, Srinivas

    2014-07-01

    This work focuses on the development and experimental evaluation of micromachined chromatographic columns for use in a commercial gas chromatography (GC) system. A vespel/graphite ferrule based compression sealing technique is presented using which leak-proof fluidic interconnection between the inlet tubing and the microchannel was achieved. This sealing technique enabled separation at temperatures up to 350°C on a μGC column. This paper reports the first high-temperature separations in microfabricated chromatographic columns at these temperatures. A 2m microfabricated column using a double Archimedean spiral design with a square cross-section of 100μm×100μm has been developed using silicon microfabrication techniques. The microfabricated column was benchmarked against a 2m 100μm diameter commercial column and the performance between the two columns was evaluated in tests performed under identical conditions. High temperature separations of simulated distillation (ASTM2887) and polycyclic aromatic hydrocarbons (EPA8310) were performed using the μGC column in temperature programmed mode. The demonstrated μGC column along with the high temperature fixture offers one more solution toward potentially realizing a portable μGC device for the detection of semi-volatile environmental pollutants and explosives without the thermal limitations reported to date with μGC columns using epoxy based interconnect technology. PMID:24866564

  9. An explanation for differences in the process of colloid adsorption in batch and column studies

    NASA Astrophysics Data System (ADS)

    Treumann, Svantje; Torkzaban, Saeed; Bradford, Scott A.; Visalakshan, Rahul M.; Page, Declan

    2014-08-01

    It is essential to understand the mechanisms that control virus and bacteria removal in the subsurface environment to assess the risk of groundwater contamination with fecal microorganisms. This study was conducted to explicitly provide a critical and systematic comparison between batch and column experiments. The aim was to investigate the underlying factors causing the commonly observed discrepancies in colloid adsorption process in column and batch systems. We examined the colloid adsorption behavior of four different sizes of carboxylate-modified latex (CML) microspheres, as surrogates for viruses and bacteria, on quartz sand in batch and column experiments over a wide range of solution ionic strengths (IS). Our results show that adsorption of colloids in batch systems should be considered as an irreversible attachment because the attachment/detachment model was found to be inadequate in describing the batch results. An irreversible attachment-blocking model was found to accurately describe the results of both batch and column experiments. The rate of attachment was found to depend highly on colloid size, solution IS and the fraction of the sand surface area favorable for attachment (Sf). The rate of attachment and Sf values were different in batch and column experiments due to differences in the hydrodynamic of the system, and the role of surface roughness and pore structure on colloid attachment. Results from column and batch experiments were generally not comparable, especially for larger colloids (≥ 0.5 μm). Predictions based on classical DLVO theory were found to inadequately describe interaction energies between colloids and sand surfaces.

  10. Sub-to super-ambient temperature programmable microfabricated gas chromatography column

    DOEpatents

    Robinson, Alex L.; Anderson, Lawrence F.

    2004-03-16

    A sub- to super-ambient temperature programmable microfabricated gas chromatography column enables more efficient chemical separation of chemical analytes in a gas mixture by combining a thermoelectric cooler and temperature sensing on the microfabricated column. Sub-ambient temperature programming enables the efficient separation of volatile organic compounds and super-ambient temperature programming enables the elution of less volatile analytes within a reasonable time. The small heat capacity and thermal isolation of the microfabricated column improves the thermal time response and power consumption, both important factors for portable microanalytical systems.

  11. Evaluation of the secondary consolidation of columns for liquid chromatography by ultrasonic irradiation.

    PubMed

    Shalliker, R A; Broyles, B S; Guiochon, G

    2000-05-12

    The consolidation of packed analytical chromatography columns was carried out under ultrasonic irradiation. Columns were first packed using a conventional high pressure downward slurry method. Then, they were subjected to further bed consolidation in the presence of ultrasonic vibration. This process of further bed consolidation is referred to as secondary consolidation. Secondary consolidation was observed to occur more readily in solvents of low viscosity and at low flow-rates (low pressures). Column efficiency was not observed to be a factor affecting the process of secondary consolidation of the packed bed. PMID:10866062

  12. Novel Design for Centrifugal Counter-Current Chromatography: III. Saw Tooth Column.

    PubMed

    Yang, Yi; Aisa, Haji Akber; Ito, Yoichiro

    2010-01-01

    The toroidal coil using an equilateral triangular core and zigzag pattern column have improved both retention of the stationary phase and peak resolution of the conventional toroidal coil in centrifugal counter-current chromatography. To further improve the retention of stationary phase and peak resolution, a novel saw tooth column was designed and the performance of the system was evaluated at various flow rates. The results indicated that both retention of the stationary phase and peak resolution were improved as the flow rate was decreased and at a flow rate of 0.005 ml/min the resolution is remarkably increased. Modification of the tubing called flat-twisted tubing further improved the peak resolution without increasing the column pressure. With a decreased column length at a capacity of about 0.2 ml, resolution of the saw tooth column was 1.02. PMID:20543965

  13. Separation of the Carotenoid Bixin from Annatto Seeds Using Thin-Layer and Column Chromatography

    ERIC Educational Resources Information Center

    McCullagh, James V.; Ramos, Nicholas

    2008-01-01

    In this experiment the carotenoid bixin is isolated from annatto ("Bixa orellana") seeds using column chromatography. The experiment has several key advantages over previous pigment separation experiments. First, unlike other experiments significant quantities of the carotenoid (typically 20 to 25 mg) can be isolated from small quantities of plant…

  14. A Computer-Interfaced Drop Counter as an Inexpensive Fraction Collector for Column Chromatography

    ERIC Educational Resources Information Center

    Nash, Barbara T.

    2008-01-01

    A computer-interfaced drop counter is described that serves as an inexpensive alternative to a fraction collector for column chromatography experiments. Undergraduate biochemistry laboratories frequently do not have the budget to purchase fraction collectors. Protocols that call for the manual measurement of fraction volumes as well as the manual…

  15. The fabrication of all-silicon micro gas chromatography columns using gold diffusion eutectic bonding

    NASA Astrophysics Data System (ADS)

    Radadia, A. D.; Salehi-Khojin, A.; Masel, R. I.; Shannon, M. A.

    2010-01-01

    Temperature programming of gas chromatography (GC) separation columns accelerates the elution rate of chemical species through the column, increasing the speed of analysis, and hence making it a favorable technique to speedup separations in microfabricated GCs (micro-GC). Temperature-programmed separations would be preferred in an all-silicon micro-column compared to a silicon-Pyrex® micro-column given that the thermal conductivity and diffusivity of silicon is 2 orders of magnitude higher than Pyrex®. This paper demonstrates how to fabricate all-silicon micro-columns that can withstand the temperature cycling required for temperature-programmed separations. The columns were sealed using a novel bonding process where they were first bonded using a gold eutectic bond, then annealed at 1100 °C to allow gold diffusion into silicon and form what we call a gold diffusion eutectic bond. The gold diffusion eutectic-bonded micro-columns when examined using scanning electron microscopy (SEM), scanning acoustic microscopy (SAM) and blade insertion techniques showed bonding strength comparable to the previously reported anodic-bonded columns. Gas chromatography-based methane injections were also used as a novel way to investigate proper sealing between channels. A unique methane elution peak at various carrier gas inlet pressures demonstrated the suitability of gold diffusion eutectic-bonded channels as micro-GC columns. The application of gold diffusion eutectic-bonded all-silicon micro-columns to temperature-programmed separations (120 °C min-1) was demonstrated with the near-baseline separation of n-C6 to n-C12 alkanes in 35 s.

  16. Evaluation of column hardware on liquid chromatography-mass spectrometry of phosphorylated compounds.

    PubMed

    Sakamaki, Hiroshi; Uchida, Takeharu; Lim, Lee Wah; Takeuchi, Toyohide

    2015-02-13

    The influences of column hardware, such as chromatographic tubes and frits, on liquid chromatography-mass spectrometry (LC-MS) analysis of phosphorylated compounds were evaluated. The signal to noise ratio (S/N) and the intensity of flavin adenine dinucleotide (FAD) using a glass lined tube and polyethylene frit (GL-PE) column was approximately 170 and 90 times higher, respectively, than those using conventional stainless steel tube and stainless steel frit (S-S) column. In addition, the retention time of FAD using GL-PE column was the shortest compared to other columns. Interaction between phosphorylated compounds and metal ions in the flow path in the S-S column was stronger than that between them and the GL-PE column. Thus, the metal ions in the flow path in GL-PE column were low. Since the specific surface area of a pair of frits was 70 times larger than that of a chromatographic tube (150 mm×2.1 mm), the frits were found to have more effective improvement of the S/N as well as the intensity than the chromatographic tubes, when phosphorylated compounds were analyzed by LC-MS. When the evaluated phosphorylated compounds were analyzed by LC-MS(/MS) using a GL-PE column, the intensity and S/N were increased. PMID:25604270

  17. Competitive adsorption of furfural and phenolic compounds onto activated carbon in fixed bed column.

    PubMed

    Sulaymon, Abbas H; Ahmed, Kawther W

    2008-01-15

    For a multicomponent competitive adsorption of furfural and phenolic compounds, a mathematical model was builtto describe the mass transfer kinetics in a fixed bed column with activated carbon. The effects of competitive adsorption equilibrium constant, axial dispersion, external mass transfer, and intraparticle diffusion resistance on the breakthrough curve were studied for weakly adsorbed compound (furfural) and strongly adsorbed compounds (parachlorophenol and phenol). Experiments were carried out to remove the furfural and phenolic compound from aqueous solution. The equilibrium data and intraparticle diffusion coefficients obtained from separate experiments in a batch adsorber, by fitting the experimental data with theoretical model. The results show that the mathematical model includes external mass transfer and pore diffusion using nonlinear isotherms and provides a good description of the adsorption process for furfural and phenolic compounds in a fixed bed adsorber. PMID:18284136

  18. Hexavalent chromium removal performance of anionic functionalized monolithic polymers: column adsorption, regeneration and modelling.

    PubMed

    Barlik, Necla; Keskinler, Bülent; Kocakerim, M Muhtar

    2016-01-01

    Anionic functionalized monolithic macro-porous polymers were used for the removal of hexavalent chromium(VI) anions from aqueous solution in column experiments. At a flux of 1.0 cm min and 30 mg Cr(VI) L(-1) feed concentration, breakthrough capacity and apparent capacity were 0.066 g Cr(VI) g(-1) anionic monolith and 0.144 g Cr(VI) g(-1) anionic monolith, respectively. The degree of column utilization was found to lie in the range 41-46%. Two kinetic models, theoretical and Thomas models, were applied to experimental data to predict the breakthrough curves and to determine the characteristic parameters of the column useful for process design. The simulation of the whole breakthrough curve was effective with the models. At a flux of 1.0 cm min and 30 mg Cr(VI) L(-1) feed concentration, the dispersion coefficient and adsorption equilibrium constant (K) were 3.14 × 10(-7) m s(-1) and 3,840, respectively. Also, Thomas model parameters k1 (rate constant of adsorption) and qm (equilibrium solid-phase concentration of sorbed solute) were 1.08 × 10(-3) L mg(-1) min(-1) and 0.124 g g(-1), respectively. After reaching equilibrium adsorption capacity, the monoliths were regenerated using 1 N HCl and were subsequently re-tested. It was found that the regeneration efficiency reduced from 98% after second usage to 97% after the third usage. PMID:27003067

  19. Adsorption mechanisms and effect of temperature in reversed-phase liquid chromatography. meaning of the classical Van't Hoff plot in chromatography.

    PubMed

    Gritti, Fabrice; Guiochon, Georges

    2006-07-01

    The effect of temperature on the adsorption and retention behaviors of a low molecular weight compound (phenol) on a C18-bonded silica column (C18-Sunfire, Waters) from aqueous solutions of methanol (20%) or acetonitrile (15%) was investigated. The results of the measurements were interpreted successively on the basis of the linear (i.e., overall retention factors) and the nonlinear (i.e., adsorption isotherms, surface heterogeneity, saturation capacities, and equilibrium constants) chromatographic methods. The confrontation of these two approaches confirmed the impossibility of a sound physical interpretation of the conventional Van't Hoff plot. The classical linear chromatography theory assumes that retention is determined by the equilibrium thermodynamics of analytes between a homogeneous stationary phase and a homogeneous mobile phase (although there may be two or several types of interactions). From values of the experimental retention factors in a temperature interval and estimates of the activity coefficients at infinite dilution in the same temperature interval provided by the UNIFAC group contribution method, evidence is provided that such a retention model cannot hold. The classical Van't Hoff plot appears meaningless and its linear behavior a mere accident. Results from nonlinear chromatography confirm these conclusions and provide explanations. The retention factors seem to fulfill the Van't Hoff equation, not the Henry constants corresponding to the different types of adsorption sites. The saturation capacities and the adsorption energies are clearly temperature dependent. The temperature dependence of these characteristics of the different assorption sites are different in aqueous methanol and acetonitrile solutions. PMID:16808477

  20. Post-column labeling techniques in amino acid analysis by liquid chromatography.

    PubMed

    Rigas, Pantelis G

    2013-10-01

    Amino acid analysis (AAA) has always presented an analytical challenge in terms of sample preparation, separation, and detection. Because of the vast number of amino acids, various separation methods have been applied taking into consideration the large differences in their chemical structures, which span from nonpolar to highly polar side chains. Numerous separation methods have been developed in the past 60 years, and impressive achievements have been made in the fields of separation, derivatization, and detection of amino acids (AAs). Among the separation methods, liquid chromatography (LC) prevailed in the AAA field using either pre-column or post-column labeling techniques in order to improve either separation of AAs or selectivity and sensitivity of AAA. Of the two approaches, the post-column technique is a more rugged and reproducible method and provides excellent AAs separation relatively free from interferences. This review considers current separations combined with post-column labeling techniques for AAA, comparison with the pre-column methods, and the strategies used to develop effective post-column methodology. The focus of the article is on LC methods coupled with post-column labeling techniques and studying the reactions to achieve optimum post-column derivatization (PCD) conditions in order to increase sensitivity and selectivity using various types of detectors (UV-Vis, fluorescence, electrochemical etc.) and illustrating the versatility of the PCD methods for practical analysis. PMID:24013667

  1. Poly(HEMA-co-NBMI) monolithic cryogel columns for IgG adsorption.

    PubMed

    Uygun, Murat; Şenay, R Hilal; Avcıbaşı, Nesibe; Akgöl, Sinan

    2014-02-01

    Supermacroporous poly(2-hydroxyethyl methacrylate-co-1,5-naphthalene bismaleimide) [poly(HEMA-co-NBMI)] monolithic cryogel column was prepared by free radical cryo-copolymerization of HEMA with NBMI as a hydrophobic functional comonomer and N,N'-methylene-bisacrylamide as cross-linker directly in a plastic syringe for adsorption of albumin. The monolithic cryogel contained a continuous polymeric matrix which has interconnected pores of 10-100 μm size. Poly(HEMA-co-NBMI) cryogel was characterized by swelling studies, FTIR and scanning electron microscopy. The equilibrium swelling degree of the poly(HEMA-co-NBMI) cryogel was 10.5 g of H₂O/g dry cryogel. Poly(HEMA-co-NBMI) cryogel was used in the adsorption/desorption of IgG from aqueous solutions. The maximum amount of IgG adsorption from aqueous solution in phosphate buffer was 98.20 mg/g polymer at pH 7.0. The nonspecific adsorption of IgG onto plain poly(HEMA) cryogel was very low (2.79 g/g polymer). It was observed that IgG could be repeatedly adsorbed and desorbed with the poly(HEMA-co-NBMI) cryogel without significant loss of adsorption capacity. PMID:24233543

  2. Enhanced interpretation of adsorption data generated by liquid chromatography and by modern biosensors.

    PubMed

    Agmo Hernández, Víctor; Samuelsson, Jörgen; Forssén, Patrik; Fornstedt, Torgny

    2013-11-22

    In this study we demonstrate the importance of proper data processing in adsorption isotherm estimations. This was done by investigating and reprocessing data from five cases on two closely related platforms: liquid chromatography (LC) and biosensors. The previously acquired adsorption data were reevaluated and reprocessed using a three-step numerical procedure: (i) preprocessing of adsorption data, (ii) adsorption data analysis and (iii) final rival model fit. For each case, we will discuss what we really measure and what additional information can be obtained by numerical processing of the data. These cases clearly demonstrate that numerical processing of LC and biosensor data can be used to gain deeper understanding of molecular interactions with adsorption media. This is important because adsorption data, especially from biosensors, is often processed using old and simplified methods. PMID:23928411

  3. Overloading study of basic compounds with a positively charged C18 column in liquid chromatography.

    PubMed

    Wang, Chaoran; Guo, Zhimou; Long, Zhen; Zhang, Xiuli; Liang, Xinmiao

    2013-03-15

    While tailing and overloading of basic compounds remain problematic on most RP columns, a new kind of positively charged RP column named XCharge C18 was found to be superior good for the separation of alkaloids in our practical use. In this work, the surface charge property of the XCharge C18 column was evaluated by the retention of NO(3)(-) under different pH values and buffer concentrations. A considerable and pH-dependent positive charge was confirmed on the column. Then overloading behaviors of bases were systematically studied using amitriptyline as a basic probe. Good peak shapes (Tf<1.5) and extra high loadability with a C(0.5) of about 30,000 mg/L were observed on the column, with commonly used 0.1% formic acid as mobile phase additive. However, increasing the ionic strength of buffer with phosphates led to tailing peaks at high sample amount and sharp decline in loadability (C(0.5) of 2000-3000 mg/L), although it brought higher column efficiency at low sample amount. Higher pH also induced worse performance and lower loadability. The overall results demonstrated the importance of an appropriate level of ionic repulsion for the XCharge C18 column to achieve the good performance for bases, which could be explained by the multiple-site adsorption theory as ionic repulsion would shield the solute from occupying high-energy sites deeper in C18 layer. PMID:23411141

  4. Regenerated silica gel as stationary phase on vacuum column chromatography to purify temulawak’s extracts

    SciTech Connect

    Cahyono, Bambang; Maduwu, Ratna Dewi; Widayat,; Suzery, Meiny

    2015-12-29

    Commercial silica gel only used once by many researchers and affected high cost for purification process, also less support the green chemistry program. This research focused in regeneration silica gel that used purification of temulawak’s extracts (Curcuma xanthorrhiza Roxb) by vacuum column chromatography. Sample extracts (contains 10.1195±0.5971% of curcuminoids) was purified by vacuum column chromatography (pressure: 45 kPa, column: 100mm on length and 16mm on diameter). Ethanol 96% and acetone were compared as eluent. The amount of solvent and yield of curcuminoids used as indicator purification. The silica gel was regenerated with heating in 600°C for 8 hours The silica gels were analyzed by IR spectroscopy and X-ray diffraction. Furthermore, regenerated silica gel was used as the stationary phase in vacuum column chromatography under the same conditions with the previous purification. All the purification experiments were performed in three repetitions. Based on regression equation, y=0.132x+0.0011 (r{sup 2}=0.9997) the yield of curcuminoids on purified products using ethanol as the eluent was improved 4.26% (to 14.3724±0.5749%) and by acetone was improved 3,03% (to 13.1450 ±0.6318%). The IR spectrum of both silica gel showed the same vibration profile and also there were three crystallinity peaks missing on its X-ray diffraction. Regenerated silica gel has the same performance with new silica gel in purification of temulawak’s extract: by ethanol has increased 4.08% (14.1947±0.7415%) and 2.93% (13.0447±0.4822) by acetone. In addition, all purification products showed similar TLC profiles. Purification using regenerated silica gel as the adsorbent on vacuum column chromatography has exactly same potential with the new silica gel.

  5. Regenerated silica gel as stationary phase on vacuum column chromatography to purify temulawak's extracts

    NASA Astrophysics Data System (ADS)

    Cahyono, Bambang; Maduwu, Ratna Dewi; Widayat, Suzery, Meiny

    2015-12-01

    Commercial silica gel only used once by many researchers and affected high cost for purification process, also less support the green chemistry program. This research focused in regeneration silica gel that used purification of temulawak's extracts (Curcuma xanthorrhiza Roxb) by vacuum column chromatography. Sample extracts (contains 10.1195±0.5971% of curcuminoids) was purified by vacuum column chromatography (pressure: 45 kPa, column: 100mm on length and 16mm on diameter). Ethanol 96% and acetone were compared as eluent. The amount of solvent and yield of curcuminoids used as indicator purification. The silica gel was regenerated with heating in 600°C for 8 hours The silica gels were analyzed by IR spectroscopy and X-ray diffraction. Furthermore, regenerated silica gel was used as the stationary phase in vacuum column chromatography under the same conditions with the previous purification. All the purification experiments were performed in three repetitions. Based on regression equation, y=0.132x+0.0011 (r2=0.9997) the yield of curcuminoids on purified products using ethanol as the eluent was improved 4.26% (to 14.3724±0.5749%) and by acetone was improved 3,03% (to 13.1450 ±0.6318%). The IR spectrum of both silica gel showed the same vibration profile and also there were three crystallinity peaks missing on its X-ray diffraction. Regenerated silica gel has the same performance with new silica gel in purification of temulawak's extract: by ethanol has increased 4.08% (14.1947±0.7415%) and 2.93% (13.0447±0.4822) by acetone. In addition, all purification products showed similar TLC profiles. Purification using regenerated silica gel as the adsorbent on vacuum column chromatography has exactly same potential with the new silica gel.

  6. Determination of zearalenone in cereal grains, animal feed, and feed ingredients using immunoaffinity column chromatography and liquid chromatography: interlaboratory study.

    PubMed

    Campbell, Harold M; Armstrong, J Fred

    2007-01-01

    A method using immunoaffinity column chromatography (IAC) and liquid chromatography (LC) for determination of zearalenone in cereal grains, animal feed, and feed ingredients was collaboratively studied. The test portion is extracted by shaking with acetonitrile-water (90 + 10, v/v) and sodium chloride. The extract is diluted and applied to an immunoaffinity column, the column is washed with water or phosphate-buffered saline or methanol-water (30 + 70, v/v), and zearalenone is eluted with methanol. The eluate is evaporated, the residue is dissolved in mobile phase and analyzed by reversed-phase LC with fluorescence detection. The presence of zearalenone can be confirmed using an alternate excitation wavelength or diode array detection. Twenty samples were sent to 13 collaborators (8 in Europe, 2 in the United States, one in Japan, one in Uruguay, and one in Canada). Eighteen samples of naturally contaminated corn, barley, wheat, dried distillers grains, swine feed, and dairy feed were analyzed as blind duplicates, along with blank corn and wheat samples. The analyses were done in 2 sample sets with inclusion of a spiked wheat control sample (0.1 mg/kg) in each set. Spiked samples recoveries were 89-116%, and for the 18 naturally contaminated samples, RSDr values (within-laboratory repeatability) ranged from 6.67 to 12.1%, RSDR values (among-laboratory reproducibility) ranged from 12.5 to 19.7%, and HorRat values ranged from 0.61 to 0.90. PMID:18193738

  7. High Pressure Size Exclusion Chromatography (HPSEC) of humic substances: molecular sizes, analytical parameters, and column performance

    PubMed

    Conte; Piccolo

    1999-02-01

    High Pressure Size Exclusion chromatography (HPSEC) is increasingly used to evaluate molecular sizes of humic substances from different sources. Asymmetry factors (As), number of theoretical plates (N), coefficient of distribution (k(d)), and column resolution (Rs) were determined for two different HPSEC columns (TSK G3000SW and Biosep S2000) and polysaccharides of known molecular weights were used as standards. Calibration curves were equivalent for both columns whereas analytical parameters revealed that the TSK column was only slightly more efficient in separating polysaccharide standards. Mw and Mn values for humic substances differed according to the molecular weight range of each column but relative standard deviation never exceeded 5% for both columns. Variations between columns were attributed to intrinsic humic properties such as the stability of conformational structures. These results suggested that humic substances in solutions are loosely-bound association of small molecules that may be consistently dispersed by diffusion through size-exclusion pores. HPSEC is confirmed to represent a highly precise method to evaluate the relative molecular-size distribution of dissolved humic substances. PMID:10901671

  8. Group-type separation of diesel fuels using packed capillary column supercritical fluid chromatography

    SciTech Connect

    Li, W.; Malik, A.; Lee, M.L. ); Jones, B.A.; Porter, N.L.; Richter, B.E. )

    1995-02-01

    Determination of the aromatic hydrocarbon content of diesel fuels by supercritical fluid chromatography (SFC) has been approved as an American Standard Test Method. Commercially available microbore columns usually used in this application suffer from poor stability and low resolution. In this work, 200 [mu]m i.d. packed capillary SFC columns were prepared, and their chromatographic performances were compared with commercial microbore columns. Various packing materials with different pore sizes were evaluated, and the effects of column temperature and pressure were carefully examined. It was found that the pore size of the packing material and, therefore, the surface area had a significant effect on elution order. Using a 1 m long column, a resolution of as high as 15 for n-hexadecane and toluene was achieved within 5 min at 45[degree]C. The column performance was very reproducible; day-to-day and month-to-month resolution variations were less than 3%, and retention time variations were less than 1%. In this method, no additional columns and valve switching were involved. The method is simple, fast (approximately 10 min), and very suitable for quality control analysis. 35 refs., 5 figs., 7 tabs.

  9. Column chromatography as a useful step in purification of diatom pigments.

    PubMed

    Tokarek, Wiktor; Listwan, Stanisław; Pagacz, Joanna; Leśniak, Piotr; Latowski, Dariusz

    2016-01-01

    Fucoxanthin, diadinoxanthin and diatoxanthin are carotenoids found in brown algae and most other heterokonts. These pigments are involved in photosynthetic and photoprotective reactions, and they have many potential health benefits. They can be extracted from diatom Phaeodactylum tricornutum by sonication, extraction with chloroform : methanol and preparative thin layer chromatography. We assessed the utility of an additional column chromatography step in purification of these pigments. This novel addition to the isolation protocol increased the purity of fucoxanthin and allowed for concentration of diadinoxanthin and diatoxanthin before HPLC separation. The enhanced protocol is useful for obtaining high purity pigments for biochemical studies. PMID:27486920

  10. A soil-column gas chromatography (SCGC) approach to explore the thermal desorption behavior of hydrocarbons from soils.

    PubMed

    Yu, Ying; Liu, Liang; Shao, Ziying; Ju, Tianyu; Sun, Bing; Benadda, Belkacem

    2016-01-01

    A soil-column gas chromatography approach was developed to simulate the mass transfer process of hydrocarbons between gas and soil during thermally enhanced soil vapor extraction (T-SVE). Four kinds of hydrocarbons-methylbenzene, n-hexane, n-decane, and n-tetradecane-were flowed by nitrogen gas. The retention factor k' and the tailing factor T f were calculated to reflect the desorption velocities of fast and slow desorption fractions, respectively. The results clearly indicated two different mechanisms on the thermal desorption behaviors of fast and slow desorption fractions. The desorption velocity of fast desorption fraction was an exponential function of the reciprocal of soil absolute temperature and inversely correlated with hydrocarbon's boiling point, whereas the desorption velocity of slow desorption fraction was an inverse proportional function of soil absolute temperature, and inversely proportional to the log K OW value of the hydrocarbons. The higher activation energy of adsorption was found on loamy soil with higher organic content. The increase of carrier gas flow rate led to a reduction in the apparent activation energy of adsorption of slow desorption fraction, and thus desorption efficiency was significantly enhanced. The obtained results are of practical interest for the design of high-efficiency T-SVE system and may be used to predict the remediation time. PMID:26335523

  11. Selecting the column configuration with lowest media replacement cost for small adsorption systems.

    PubMed

    Bausk, Artem S; Dvorak, Bruce I

    2016-04-15

    A framework was developed for preliminary evaluation of the relative media replacement costs of three alternative column configurations used for adsorption systems with two vessels, such as those serving small systems. The media replacement cost is the cost of fresh media and the replacement service cost (including transportation, labor, and other non-material costs). Cost normalization methods were developed in part based on the data from US EPA Arsenic Treatment Technology Demonstration Program. Adsorption equilibrium and kinetics were modeled using the PSDM model and breakthrough curves were normalized using the target effluent to influent concentration ratio (C/Co) and the mass transfer zone fraction (%MTZBT). Two factors were found to be important for the relative replacement cost of each configuration - the frequency which at least one column needed replacement of media, and the cycle replacement cost (CRCost) which is a combination of the fresh media cost and the replacement service cost. The lead-lag configuration has the lowest annual replacement cost at low target C/Co, high %MTZBT, and high CRCost ratios. The parallel configuration performs better at high target C/Co, high %MTZBT, and high CRCost ratios. Although the single configuration (two columns operated in tandem and replaced simultaneously) has higher media consumption compared to lead-lag and parallel, it can result in the lowest replacement cost at short %MTZBT and very low CRCost ratios due to savings in the replacement service cost. PMID:26894474

  12. Size exclusion chromatography of synthetic polymers and biopolymers on common reversed phase and hydrophilic interaction chromatography columns.

    PubMed

    Caltabiano, Anna M; Foley, Joe P; Barth, Howard G

    2016-03-11

    This work describes the applicability of common reversed phase and HILIC columns for size exclusion chromatography of synthetic and natural polymers. Depending on the nature of the solute and column stationary phase, a "non-retention" condition must be created with the aid of the mobile phase to achieve a unique size-based separation in isocratic mode. The various bonded phases show remarkable differences in size separations that are controlled by mobile phase conditions. Polymer-mobile phase and column-mobile phase solvation interactions determine polymer hydrodynamic volume (or solute bulkiness) and polymer-column steric interaction. Solvation interactions in turn depend on polymer, mobile phase and stationary phase polarities. Column-mobile phase solvation interactions determine the structural order of the bonded ligands that can vary from ordered (extended, aligned away from the silica substrate) to disordered (folded, pointing toward the silica substrate). Chain order increases with increased solvent penetration into the bonded phase. Increased chain order reduces pore volume, and therefore decreases the size-separation efficiency of a column. Conversely, decreased chain order increases pore volume and therefore increases the size-separation efficiency. The thermodynamic quality of the mobile phase also plays a significant role in the separation of polymers. "Poor" solvents can significantly reduce the hydrodynamic diameter of a solute and thus change their retention behavior. Medium polarity stationary phases, such as fluoro-phenyl and cyano, exhibit a unique retention behavior. With an appropriate polarity mobile phase, polar and non-polar synthetic polymers of the same molecular masses can be eluted at the same retention volumes. PMID:26877177

  13. [Analysis of oxygenates from fischer-Tropsch synthesis oil using column liquid chromatography and gas chromatography-mass spectrography].

    PubMed

    Fan, Gaixian; Xu, Yuanyuan; Li, Ying; Li, Ying; Xiang, Hongwei; Li, Yongwang

    2007-11-01

    A liquid chromatographic column filled with silica gel of 100 - 200 mesh was used to separate cold trap oil from Fischer-Tropsch synthesis with dimethylsulfoxide (DMSO) as eluent. With this pretreatment method, the cold trap oil was separated into two major classes, namely, hydrocarbons and oxygenates. Minor components were also enriched and determined, and small peaks adjacent to big peaks and tailings were also well solved. The oxygenates were then analyzed with gas chromatography-mass spectrometry (GC-MS), and 139 components were identified. PMID:18257312

  14. High performance mini-gas chromatography-flame ionization detector system based on micro gas chromatography column

    NASA Astrophysics Data System (ADS)

    Zhu, Xiaofeng; Sun, Jianhai; Ning, Zhanwu; Zhang, Yanni; Liu, Jinhua

    2016-04-01

    Monitoring Volatile organic compounds (VOCs) was a very important measure for preventing environmental pollution, therefore, a mini gas chromatography (GC) flame ionization detector (FID) system integrated with a mini H2 generator and a micro GC column was developed for environmental VOC monitoring. In addition, the mini H2 generator was able to make the system explode from far away due to the abandoned use of a high pressure H2 source. The experimental result indicates that the fabricated mini GC FID system demonstrated high repeatability and very good linear response, and was able to rapidly monitor complicated environmental VOC samples.

  15. High performance mini-gas chromatography-flame ionization detector system based on micro gas chromatography column.

    PubMed

    Zhu, Xiaofeng; Sun, Jianhai; Ning, Zhanwu; Zhang, Yanni; Liu, Jinhua

    2016-04-01

    Monitoring Volatile organic compounds (VOCs) was a very important measure for preventing environmental pollution, therefore, a mini gas chromatography (GC) flame ionization detector (FID) system integrated with a mini H2 generator and a micro GC column was developed for environmental VOC monitoring. In addition, the mini H2 generator was able to make the system explode from far away due to the abandoned use of a high pressure H2 source. The experimental result indicates that the fabricated mini GC FID system demonstrated high repeatability and very good linear response, and was able to rapidly monitor complicated environmental VOC samples. PMID:27131686

  16. Metal-Organic Framework Thin Films as Stationary Phases in Microfabricated Gas-Chromatography Columns.

    SciTech Connect

    Read, Douglas; Sillerud, Colin Halliday

    2016-01-01

    The overarching goal of this project is to integrate Sandia's microfabricated gas-chromatography ( GC) columns with a stationary phase material that is capable of retaining high-volatility chemicals and permanent gases. The successful integration of such a material with GCs would dramatically expand the repertoire of detectable compounds for Sandia's various microanalysis systems. One such promising class of candidate materials is metal-organic frameworks (MOFs). In this report we detail our methods for controlled deposition of HKUST-1 MOF stationary phases within GC columns. We demonstrate: the chromatographic separation of natural gas; a method for determining MOF film thickness from chromatography alone; and the first-reported GC x GC separation of natural gas -- in general -- let alone for two disparate MOF stationary phases. In addition we determine the fundamental thermodynamic constant for mass sorption, the partition coefficient, for HKUST-1 and several light hydrocarbons and select toxic industrial chemicals.

  17. Application of ultrasonic backscattering for level measurement and process monitoring of expanded-bed adsorption columns.

    PubMed

    Thelen, T V; Mairal, A P; Thorsen, C S; Ramirez, W F

    1997-01-01

    Expanded-bed adsorption is a newly commercialized technique for the purification of proteins from cellular debris in downstream processing. An expanded bed presents the possibility of protein recovery in a single step, eliminating the often costly clarification processing steps such as ultrafiltration, centrifugation, and precipitation. A major obstacle to the successful commercialization of this technology is the inability to accurately monitor and control the bed height in these systems. Fluctuations in the feedstock viscosity are common during normal operation and tend to make the operation and control of expanded beds for biological applications complex and difficult. We develop a level measurement technique based upon ultrasonics. It is shown that this technique has great promise for bed-height measurement in expanded-bed adsorption systems. Furthermore, the bed-height measurement can be used in feedback control strategies for bed-height regulation. The proposed ultrasonic sensor is also capable of monitoring for plugging and bubbling in the column. PMID:9336988

  18. Signal analysis of NEMS sensors at the output of a chromatography column

    SciTech Connect

    Bertholon, François; Harant, Olivier; Bourlon, Bertrand; Gerfault, Laurent; Grangeat, Pierre; Jutten, Christian

    2015-01-13

    This article introduces a joined Bayesian estimation of gas samples issued from a gas chromatography column (GC) coupled with a NEMS sensor based on Giddings Eyring microscopic molecular stochastic model. The posterior distribution is sampled using a Monte Carlo Markov Chain and Gibbs sampling. Parameters are estimated using the posterior mean. This estimation scheme is finally applied on simulated and real datasets using this molecular stochastic forward model.

  19. Amine Gradient Stationary Phases on In-House Built Monolithic Columns for Liquid Chromatography.

    PubMed

    Dewoolkar, Veeren C; Jeong, Lena N; Cook, Daniel W; Ashraf, Kayesh M; Rutan, Sarah C; Collinson, Maryanne M

    2016-06-01

    Stationary phase gradients on monolithic silica columns have been successfully and reproducibly prepared and characterized with comparisons made to uniformly modified stationary phases. Stationary phase gradients hold great potential for use in liquid chromatography (LC), both in terms of simplifying analysis as well as providing novel selectivity. In this work, we demonstrate the creation of a continuous stationary phase gradient on in-house synthesized monolithic columns by infusing an aminoalkoxysilane solution through the silica monoliths via controlled rate infusion. The presence of amine and its distribution along the length of gradient and uniformly modified columns were assessed via X-ray photoelectron spectroscopy (XPS). XPS showed a clear gradient in surface coverage along the length of the column for the gradient stationary phases while a near uniform distribution on the uniformly modified stationary phases. To demonstrate the application of these gradient stationary phases, the separations of both nucleobases and weak acids/weak bases on these gradient stationary phases have been compared to uniformly modified and unmodified silica columns. Of particular note, the retention characteristics of 11 gradient columns, 5 uniformly modified columns, and 5 unmodified columns have been tested to establish the reproducibility of the synthetic procedures. Standard deviations of the retention factors were in the range from 0.06 to 0.5, depending on the analyte species. We show that selectivity is achieved with the stationary phase gradients that are significantly different from either uniformly modified amine or unmodified columns. These results indicate the significant promise of this strategy for creating novel stationary phases for LC. PMID:27203513

  20. Isolation and purification of blood group antigens using immuno-affinity chromatography on short monolithic columns.

    PubMed

    Mönster, Andrea; Hiller, Oliver; Grüger, Daniela; Blasczyk, Rainer; Kasper, Cornelia

    2011-02-01

    Monolithic columns have gained increasing attention as stationary phases for the separation of biomolecules and biopharmaceuticals. In the present work the performance of monolithic convective interaction media (CIM(®)) chromatography for the purification of blood group antigens was established. The proteins employed in this study are derived from blood group antigens Knops, JMH and Scianna, equipped both with a His-tag and with a V5-tag by which they can be purified. In a first step a monoclonal antibody directed against the V5-tag was immobilized on a CIM(®) Disk with epoxy chemistry. After this, the immobilized CIM(®) Disk was used in immuno-affinity chromatography to purify the three blood group antigens from cell culture supernatant. Up-scaling of the applied technology was carried out using CIM(®) Tubes. In comparison to conventional affinity chromatography, blood group antigens were also purified via His-tag using a HiTrap(®) metal-affinity column. The two purifications have been compared regarding purity, yield and purification speed. Using the monolithic support, it was possible to isolate the blood group antigens with a higher flow rate than using the conventional bed-packed column. PMID:21194702

  1. Features of the adsorption of naproxen enantiomers on weak chiral anion-exchangers in nonlinear chromatography

    SciTech Connect

    Asnin, Leonid; Kaczmarski, Krzysztof; Guiochon, Georges A

    2008-01-01

    The retention mechanism of the enantiomers of naproxen on a Pirkle-type chiral stationary phase (CSP) was studied. This CSP is made of a porous silica grafted with quinidine carbamate. It can interact with the weak organic electrolyte naproxen either by adsorbing it or by ion-exchange. Using frontal chromatography, we explored the adsorption equilibrium under such experimental conditions that naproxen dissociates or cannot dissociate. Under conditions preventing ionic dissociation, the adsorption isotherms were measured, the adsorption energy distributions determined, and the chromatographic profiles calculated. Three different types of the adsorption sites were found for both enantiomers. The density and the binding energy of these sites depend on the nature of the organic modifier. Different solute species, anions, neutral molecules, solvent-ion associates, and solute dimers can coexist in solution, giving rise to different forms of adsorption. This study showed the unexpected occurrence of secondary steps in the breakthrough profiles of S-naproxen in the adsorption mode at high concentrations. Being enantioselective, this phenomenon was assumed to result from the association of solute molecules involving a chiral selector moiety. A multisite Langmuir adsorption model was used to calculate band profiles. Although this model accounts excellently for the experimental adsorption isotherms, it does not explain all the features of the breakthrough profiles. A comparison between the calculated and experimental profiles allowed useful conclusions concerning the effects of the adsorbate-adsorbate and adsorbate-solvent interactions on the adsorption mechanism.

  2. Core-Shell Columns in High-Performance Liquid Chromatography: Food Analysis Applications

    PubMed Central

    Preti, Raffaella

    2016-01-01

    The increased separation efficiency provided by the new technology of column packed with core-shell particles in high-performance liquid chromatography (HPLC) has resulted in their widespread diffusion in several analytical fields: from pharmaceutical, biological, environmental, and toxicological. The present paper presents their most recent applications in food analysis. Their use has proved to be particularly advantageous for the determination of compounds at trace levels or when a large amount of samples must be analyzed fast using reliable and solvent-saving apparatus. The literature hereby described shows how the outstanding performances provided by core-shell particles column on a traditional HPLC instruments are comparable to those obtained with a costly UHPLC instrumentation, making this novel column a promising key tool in food analysis. PMID:27143972

  3. A micro gas chromatography column with a micro thermal conductivity detector for volatile organic compound analysis.

    PubMed

    Sun, J H; Cui, D F; Chen, X; Zhang, L L; Cai, H Y; Li, H

    2013-02-01

    In this paper, a micro gas chromatography (μGC) system contained a μGC column and a micro thermal conductivity detector (μTCD) was proposed. In order to reduce the volume of the system, some micro heaters were integrated on the surface and backside of the GC column, which could provide a robust temperature programming capability and rapidly increase the temperature of the μGC column. In addition, a silicon-glass μTCD with four-thermistor thermal conductivity cells that can offer significant advantages over previously reported designs including low dead volume, good thermal isolation, and elimination of the thermal noise was proposed in this paper. Experimental results have indicated that the μGC system with a detection limit of several ppm concentration levels separated and detected the benzene, toluene, and styrene in less than 3 min, and the μGC system also exhibited a good linear response in the test range. PMID:23464240

  4. A micro gas chromatography column with a micro thermal conductivity detector for volatile organic compound analysis

    NASA Astrophysics Data System (ADS)

    Sun, J. H.; Cui, D. F.; Chen, X.; Zhang, L. L.; Cai, H. Y.; Li, H.

    2013-02-01

    In this paper, a micro gas chromatography (μGC) system contained a μGC column and a micro thermal conductivity detector (μTCD) was proposed. In order to reduce the volume of the system, some micro heaters were integrated on the surface and backside of the GC column, which could provide a robust temperature programming capability and rapidly increase the temperature of the μGC column. In addition, a silicon-glass μTCD with four-thermistor thermal conductivity cells that can offer significant advantages over previously reported designs including low dead volume, good thermal isolation, and elimination of the thermal noise was proposed in this paper. Experimental results have indicated that the μGC system with a detection limit of several ppm concentration levels separated and detected the benzene, toluene, and styrene in less than 3 min, and the μGC system also exhibited a good linear response in the test range.

  5. Physical properties and structure of fine core-shell particles used as packing materials for chromatography relationships between particle characteristics and column performance

    SciTech Connect

    Gritti, Fabrice; Guiochon, Georges A

    2010-01-01

    The recent development of new brands of packing materials made of fine porous-shell particles, e.g., Halo and Kinetex, has brought great improvements in potential column efficiency, demanding considerable progress in the design of chromatographic instruments. Columns packed with Halo and Kinetex particles provide minimum values of their reduced plate heights of nearly 1.5 and 1.2, respectively. These packing materials have physical properties that set them apart from conventional porous particles. The kinetic performance of 4.6 mm I.D. columns packed with these two new materials is analyzed based on the results of a series of nine independent and complementary experiments: low-temperature nitrogen adsorption (LTNA), scanning electron microscopy (SEM), inverse size-exclusion chromatography (ISEC), Coulter counter particle size distributions, pycnometry, height equivalent to a theoretical plate (HETP), peak parking method (PP), total pore blocking method (TPB), and local electrochemical detection across the column exit section (LED). The results of this work establish links between the physical properties of these superficially porous particles and the excellent kinetic performance of columns packed with them. It clarifies the fundamental origin of the difference in the chromatographic performances of the Halo and the Kinetex columns.

  6. Removal of furan and phenolic compounds from simulated biomass hydrolysates by batch adsorption and continuous fixed-bed column adsorption methods.

    PubMed

    Lee, Sang Cheol; Park, Sunkyu

    2016-09-01

    It has been proposed to remove all potential inhibitors and sulfuric acid in biomass hydrolysates generated from dilute-acid pretreatment of biomass, based on three steps of sugar purification process. This study focused on its first step in which furan and phenolic compounds were selectively removed from the simulated hydrolysates using activated charcoal. Batch adsorption experiments demonstrated that the affinity of activated charcoal for each component was highest in the order of vanillic acid, 4-hydroxybenzoic acid, furfural, acetic acid, sulfuric acid, and xylose. The affinity of activated charcoal for furan and phenolic compounds proved to be significantly higher than that of the other three components. Four separation strategies were conducted with a combination of batch adsorption and continuous fixed-bed column adsorption methods. It was observed that xylose loss was negligible with near complete removal of furan and phenolic compounds, when at least one fixed-bed column adsorption was implemented in the strategy. PMID:27289057

  7. Mechanisms of chain adsorption on porous substrates and critical conditions of polymer chromatography.

    PubMed

    Cimino, Richard T; Rasmussen, Christopher J; Brun, Yefim; Neimark, Alexander V

    2016-11-01

    Polymer adsorption is a ubiquitous phenomenon with numerous technological and healthcare applications. The mechanisms of polymer adsorption on surfaces and in pores are complex owing to a competition between various entropic and enthalpic factors. Due to adsorption of monomers to the surface, the chain gains in enthalpy yet loses in entropy because of confining effects. This competition leads to the existence of critical conditions of adsorption when enthalpy gain and entropy loss are in balance. The critical conditions are controlled by the confining geometry and effective adsorption energy, which depends on the solvent composition and temperature. This phenomenon has important implications in polymer chromatography, since the retention at the critical point of adsorption (CPA) is chain length independent. However, the mechanisms of polymer adsorption in pores are poorly understood and there is an ongoing discussion in the theoretical literature about the very existence of CPA for polymer adsorption on porous substrates. In this work, we examine the mechanisms of chain adsorption on a model porous substrate using Monte Carlo (MC) simulations. We distinguish three adsorption mechanisms depending on the chain location: on external surface, completely confined in pores, and also partially confined in pores in so-called "flower" conformations. The free energies of different conformations of adsorbed chains are calculated by the incremental gauge cell MC method that allows one to determine the partition coefficient as a function of the adsorption potential, pore size, and chain length. We confirm the existence of the CPA for chain length independent separation on porous substrates, which is explained by the dominant contributions of the chain adsorption at the external surface, in particular in flower conformations. Moreover, we show that the critical conditions for porous and nonporous substrates are identical and depend only on the surface chemistry. The theoretical

  8. Determination of Sudan dyes in chili pepper powder by online solid-phase extraction with a butyl methacrylate monolithic column coupled to liquid chromatography with tandem mass spectrometry.

    PubMed

    Liu, Yao; Wang, Man-Man; Ai, Lian-Feng; Zhang, Chang-Kun; Li, Xin; Wang, Xue-Sheng

    2014-07-01

    A poly(butyl methacrylate-co-ethylene dimethacrylate) monolithic column was fabricated and used as a novel sorbent for online solid-phase extraction coupled to liquid chromatography with tandem mass spectrometry for the simultaneous determination of Sudan I-IV in chili pepper powder. The prepared columns were characterized by scanning electron microscopy, nitrogen adsorption-desorption, and pressure drop measurements. Online solid-phase extraction was performed on the synthesized monolithic column using 10 mM ammonium acetate solution as the loading solution with the aid of an online cleanup chromatography system. The desorption of Sudan I-IV was achieved with acetonitrile as the eluting solution at the flow rate of 0.5 mL/min. The extracted analytes were subsequently eluted into a C18 analytical column for chromatographic separation using a mixture of 10% acetonitrile/90% formic acid (0.5%) solution as the mobile phase. Under the optimized conditions, the developed method had linear range of 1.0-50 μg/kg, a detection limit of 0.3 μg/kg, and a quantification limit of 1.0 μg/kg for each analyte. The intraday and interday recoveries of Sudan I-IV in chili pepper powder samples ranged from 94.8 to 100.9% and 94.9 to 99.4%, respectively. The intraday and interday precision were between 3.37-7.01% and 5.01-7.68%, respectively. PMID:24723310

  9. Novel design for centrifugal counter-current chromatography: VI. Ellipsoid column.

    PubMed

    Gu, Dongyu; Yang, Yi; Xin, Xuelei; Aisa, Haji Akber; Ito, Yoichiro

    2015-01-01

    A novel ellipsoid column was designed for centrifugal counter-current chromatography. Performance of the ellipsoid column with a capacity of 3.4 mL was examined with three different solvent systems composed of 1-butanol-acetic acid-water (4:1:5, v/v) (BAW), hexane-ethyl acetate-methanol-0.1 M HCl (1:1:1:1, v/v) (HEMH), and 12.5% (w/w) PEG1000 and 12.5% (w/w) dibasic potassium phosphate in water (PEG-DPP) each with suitable test samples. In dipeptide separation with BAW system, both stationary phase retention (Sf) and peak resolution (Rs) of the ellipsoid column were much higher at 0° column angle (column axis parallel to the centrifugal force) than at 90° column angle (column axis perpendicular to the centrifugal force), where elution with the lower phase at a low flow rate produced the best separation yielding Rs at 2.02 with 27.8% Sf at a flow rate of 0.07 ml/min. In the DNP-amino acid separation with HEMW system, the best results were obtained at a flow rate of 0.05 ml/min with 31.6% Sf yielding high Rs values at 2.16 between DNP-DL-glu and DNP-β-ala peaks and 1.81 between DNP-β-ala and DNP-L-ala peaks. In protein separation with PEG-DPP system, lysozyme and myolobin were resolved at Rs of 1.08 at a flow rate of 0.03 ml/min with 38.9% Sf. Most of those Rs values exceed those obtained from the figure-8 column under similar experimental conditions previously reported. PMID:25309116

  10. Determination of zearalenone content in cereals and feedstuffs by immunoaffinity column coupled with liquid chromatography.

    PubMed

    Fazekas, B; Tar, A

    2001-01-01

    The zearalenone content of maize, wheat, barley, swine feed, and poultry feed samples was determined by immunoaffinity column cleanup followed by liquid chromatography (IAC-LC). Samples were extracted in methanol-water (8 + 2, v/v) solution. The filtered extract was diluted with distilled water and applied to immunoaffinity columns. Zearalenone was eluted with methanol, dried by evaporation, and dissolved in acetonitrile-water (3 + 7, v/v). Zearalenone was separated by isocratic elution of acetonitrile-water (50 + 50, v/v) on reversed-phase C18 column. The quantitative analysis was performed by fluorescence detector and confirmation was based on the UV spectrum obtained by a diode array detector. The mean recovery rate of zearalenone was 82-97% (RSD, 1.4-4.1%) on the original (single-use) immunoaffinity columns. The limit of detection of zearalenone by fluorescence was 10 ng/g at a signal-to-noise ratio of 10:1 and 30 ng/g by spectral confirmation in UV. A good correlation was found (R2 = 0.89) between the results obtained by IAC-LC and by the official AOAC-LC method. The specificity of the method was increased by using fluorescence detection in parallel with UV detection. This method was applicable to the determination of zearalenone content in cereals and other kinds of feedstuffs. Reusability of immunoaffinity columns was examined by washing with water after sample elution and allowing columns to stand for 24 h at room temperature. The zearalenone recovery rate of the regenerated columns varied between 79 and 95% (RSD, 3.2-6.3%). Columns can be regenerated at least 3 times without altering their performance and without affecting the results of repeated determinations. PMID:11601464

  11. The Role of Lactic Acid Adsorption by Ion Exchange Chromatography

    PubMed Central

    Zhang, Tongcun; Zhang, Jian; Jia, Shiru; Yu, Changyan; Jiang, Kunyu; Gao, Nianfa

    2010-01-01

    Background The polyacrylic resin Amberlite IRA-67 is a promising adsorbent for lactic acid extraction from aqueous solution, but little systematic research has been devoted to the separation efficiency of lactic acid under different operating conditions. Methodology/Principal Findings In this paper, we investigated the effects of temperature, resin dose and lactic acid loading concentration on the adsorption of lactic acid by Amberlite IRA-67 in batch kinetic experiments. The obtained kinetic data followed the pseudo-second order model well and both the equilibrium and ultimate adsorption slightly decreased with the increase of the temperature at 293–323K and 42.5 g/liter lactic acid loading concentration. The adsorption was a chemically heterogeneous process with a mean free energy value of 12.18 kJ/mol. According to the Boyd_plot, the lactic acid uptake process was primarily found to be an intraparticle diffusion at a lower concentration (<50 g/liter) but a film diffusion at a higher concentration (>70 g/liter). The values of effective diffusion coefficient Di increased with temperature. By using our Equation (21), the negative values of ΔG° and ΔH° revealed that the adsorption process was spontaneous and exothermic. Moreover, the negative value of ΔS° reflected the decrease of solid-liquid interface randomness at the solid-liquid interface when adsorbing lactic acid on IRA-67. Conclusions/Significance With the weakly basic resin IRA-67, in situ product removal of lactic acid can be accomplished especially from an open and thermophilic fermentation system without sterilization. PMID:21085600

  12. ENANTIOMER SEPARATION OF POLYCHLORINATED BIPHENYL ATROPISOMERS AND POLYCHLORINATED BIPHENYL RETENTION BEHAVIOR ON MODIFIED CYCLODEXTRIN CAPILLARY GAS CHROMATOGRAPHY COLUMNS

    EPA Science Inventory

    Seven commercially-available chiral capillary gas chromatography columns containing modified cyclodextrins were evaluated for their ability to separate enantiomers of the 19 stable chiral polychlorinated biphenyl (PCB) atropisomers, and for their ability to separate these enantio...

  13. High-performance liquid chromatography as a technique to determine protein adsorption onto hydrophilic/hydrophobic surfaces.

    PubMed

    Huang, Tongtong; Anselme, Karine; Sarrailh, Segolene; Ponche, Arnaud

    2016-01-30

    The purpose of this study is to evaluate the potential of simple high performance liquid chromatography (HPLC) setup for quantification of adsorbed proteins on various type of plane substrates with limited area (<3 cm(2)). Protein quantification was investigated with a liquid chromatography chain equipped with a size exclusion column or a reversed-phase column. By evaluating the validation of the method according to guidelines of the International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH), all the results obtained by HPLC were reliable. By simple adsorption test at the contact of hydrophilic (glass) and hydrophobic (polydimethylsiloxane: PDMS) surfaces, kinetics of adsorption were determined and amounts of adsorbed bovine serum albumin, myoglobin and lysozyme were obtained: as expected for each protein, the amount adsorbed at the plateau on glass (between 0.15 μg/cm(2) and 0.4 μg/cm(2)) is lower than for hydrophobic PDMS surfaces (between 0.45 μg/cm(2) and 0.8 μg/cm(2)). These results were consistent with bicinchoninic acid protein determination. According to ICH guidelines, both Reversed Phase and Size Exclusion HPLC can be validated for quantification of adsorbed protein. However, we consider the size exclusion approach more interesting in this field because additional informations can be obtained for aggregative proteins. Indeed, monomer, dimer and oligomer of bovine serum albumin (BSA) were observed in the chromatogram. On increasing the temperature, we found a decrease of peak intensity of bovine serum albumin as well as the fraction of dimer and oligomer after contact with PDMS and glass surface. As the surface can act as a denaturation parameter, these informations can have a huge impact on the elucidation of the interfacial behavior of protein and in particular for aggregation processes in pharmaceutical applications. PMID:26621686

  14. Effects of the surface concentration of fixed charges in C18-bonded stationary phases on the adsorption process and on the preparative chromatography of small ionizable compounds.

    PubMed

    Gritti, Fabrice; Guiochon, Georges

    2014-11-01

    The effects of the surface concentration of positive charges attached to the surface of research BEH-C18 hybrid particles on the overloaded band profiles and the adsorption isotherms of a neutral (caffeine) and a positively charged (nortryptilinium hydrochloride) compounds were measured and investigated. The inverse method (IM) of chromatography was used to determine the isotherm parameters. Three columns were packed with endcapped BEH-C18 particles doped with three different charge densities on their surfaces (LOW, MEDIUM and HIGH). Two other columns packed with unbonded, non-endcapped, and endcapped BEH-C18 particles served as standard reference materials. Minor disturbance method (MDM) experiments were conducted with acetonitrile/water mixtures in order to assess qualitatively the surface densities of the fixed positive charges. A more quantitative approach based on the solution of the linearized Poisson-Boltzmann equation and the decrease of the experimental Henry constant was also applied. The results show that the surface concentrations of the fixed charges in the LOW, MEDIUM and HIGH columns were 0.029, 0.050, and 0.064μmol/m(2), e.g., close to two orders of magnitude smaller than the surface density of bonded C18 chains (2.1μmol/m(2)). The adsorption isotherm of the ionizable compound nortryptilinium onto the BEH-C18 columns is consistent with a two-sites adsorption model. The density of the high energy sites correlates directly to the total amount of the fixed charges and isolated silanols amidst the C18-bonded chains. The amount of low energy sites reflects the specific surface area of the adsorbent. The binding constants on the high- and low-energy adsorption sites are respectively ten and two times lower on the HIGH column than on the reference endcapped column. The active sites are closer to the adsorbent surface than the weak adsorption sites. Finally, a higher production rate of ionizable compounds can be achieved in preparative chromatography with

  15. Treatment of cyanide effluents by oxidation and adsorption in batch and column studies.

    PubMed

    Yazici, E Y; Deveci, H; Alp, I

    2009-07-30

    In this study the removal of free cyanide from aqueous solutions by air oxidation and adsorption was investigated. Effects of air and pure oxygen, and catalyst on the rate and extent of the removal of cyanide were studied. It was found that the oxidative removal of cyanide by air/oxygen was very limited although it tended to improve in the presence of pure oxygen and catalyst such as activated carbon (AC) and copper sulphate. In the presence of continuous aeration, the non-oxidative removal of cyanide was correlated with a decrease in pH effected apparently by the transfer of carbon dioxide from air phase into the medium. The removal of cyanide by adsorption on activated carbon, nut shell (NS) and rice husk (RH) was also examined. Adsorption capacity of activated carbon was shown to be significantly enhanced via impregnation of activated carbons with metals such as copper (AC-Cu) and silver (AC-Ag). In the column tests, the breakthrough capacity of adsorbents was found to be in an increasing order of RH

  16. Continuous adsorption of natural organic matters in a column packed with carbon nanotubes

    PubMed Central

    2013-01-01

    In the present study, continuous adsorption experiments were carried out in an adsorption column to survey the efficiency of the carbon nanotubes (CNTs) for removal of natural organic matters (NOMs) from aqueous solution. Parameters such as mass of CNTs, initial NOMs concentration were evaluated and also the breakthrough curves were obtained. Experiments performed with various initial NOMs concentration and various CNTs masses. The breakthrough period was longer at lower initial NOMs concentration. Increase of the initial NOMs concentration, expectedly, resulted in the faster saturation of the CNTs bed. The adsorption capacities for multi wall carbon nanotubes (MWCNT) and single wall carbon nanotubes (SWCNT) in highest initial NOMs concentration were 53.46 and 66.24 mg/g, respectively. The effect of amount of CNTs on breakthrough time and volume of treated water was investigated and resulted that with an increase in the mass of CNTs, breakthrough time occurs very late and the volume of treated water increased. These findings suggested that CNTs present a great potential in removal of NOMs from aqueous solutions. PMID:24499604

  17. A generic approach to post-column refocusing in liquid chromatography.

    PubMed

    De Vos, Jelle; Desmet, Gert; Eeltink, Sebastiaan

    2014-09-19

    To increase detection sensitivity in liquid chromatography, a generic post-column refocusing strategy has been developed to enrich (target) analytes prior to detection. In this strategy, after separation on the analytical column, the analytes are led to a trap column preferably containing a stationary phase with strong retentive properties (e.g. silica C30). They are then eluted using a strong solvent in a backward-elution mode. A first key element of the proposed strategy is that the trapping time should be at least equal to the time the front of the remobilization solvent needs to cover the entire length of the trap column, divided by the ratio of the flow rates used for trapping and remobilization. This condition is independent of the retention properties of the analytes in the trapping and remobilization solvent. Another essential element is the addition of a third solvent (isopropanol in the present case) to the remobilization solvent to overcome viscous-fingering effects caused by the viscosity difference between the trap and the remobilization solvents. The potential of the proposed post-column refocusing strategy is demonstrated for an isocratic separation of KI (t0 marker), an antibiotic (sulfamethazine), and acetophenone as a case study. Using optimized remobilization conditions a maximum signal-enhancement factor of 8 was achieved. Higher enhancement factors using a remobilization solvent with slightly higher elution strength were prohibited by disturbances of the UV background signal. PMID:25127691

  18. Preparation and evaluation of molecularly imprinted polymer liquid chromatography column for the separation of Cathine enantiomers

    PubMed Central

    Balamurugan, Krishnamoorthy; Gokulakrishnan, Kannan; Prakasam, Tangirala

    2011-01-01

    In this study molecular imprinting technology was employed to prepare a specific affinity sorbent for the resolution of Cathine, a chiral drug product. The molecularly imprinted polymer (MIP) was prepared by non-covalent molecular imprinting with either (+) or (−)-Cathine (threo-2-amino-1-hydroxy-1-phenyl propane; norpseudoephedrine) as the template. Methacrylic acid and ethylene glycol di-methacrylate were copolymerized in the presence of the template molecule. The bulk polymerization was carried out in chloroform with 2,2′-azobisisobutyronitrile as the initiator, at 5 °C and under UV radiation. The resulting MIP was ground into powders, which were slurry packed into analytical columns. After removal of template molecules, the MIP-packed columns were found to be effective for the resolution of (±)-Cathine racemates. The separation factor for the enantiomers ranged between 1.5 and 2.4 when the column was packed with MIP prepared with (+)-Cathine as the template. A separation factor ranging from 1.6 to 2.9 could be achieved from the column packed with MIP, prepared with (−)-Cathine as the template. Although the separation factor was higher with that previously obtained from reversed-phase column chromatography following derivatization with a chiral agent, elution peaks were broader due to the heterogeneity of binding sites on MIP particles and the possible non-specific interaction. PMID:23960776

  19. Comparative Study on the Implication of Three Nanoparticles on the Removal of Trichloroethylene by Adsorption - The Pilot and Rapid Small-Scale Column Tests

    EPA Science Inventory

    The impact of three commercially-available nanoparticles (NPs) on trichloroethylene (TCE) adsorption onto granular activated carbon (GAC) was investigated. TCE Adsorption isotherm and column breakthrough experiments were conducted in the presence and absence of silicon dioxide (S...

  20. Extending the limits of operating pressure of narrow-bore column liquid chromatography instrumentation.

    PubMed

    Pauw, Ruben De; Degreef, Bart; Ritchie, Harald; Eeltink, Sebastiaan; Desmet, Gert; Broeckhoven, Ken

    2014-06-20

    The increase of the operating pressure in Liquid Chromatography, has been one of the crucial steps toward faster and more efficient separations. In the present contribution, it was investigated if the pressure limits for narrow-bore columns (2.1mm ID) could be increased beyond those of commercially available (1300bar) instrumentation without performance loss. Whereas previous studies applying pressures higher than 2000bar were limited to the use of columns with a diameter smaller or equal to 1mm, it is a difficult feat to expand this to 2.1mm ID given that viscous-heating effects increase according to the fifth power of the column radius. A prototype LC set-up was realized, allowing to operate at pressures up to 2600bar (260MPa) for large separation volumes (>5mL). The performance of an in-house-built injector was compared at 800bar to commercially available injectors, yielding equal performance but twice the maximum pressure rating. The performance of (coupled) custom columns packed with fully porous and superficially porous particles were assessed at ultra-high-pressure conditions. Increasing the inlet pressure from 800 to 2400bar and scaling the column length proportionally (from 150mm to 450mm), resulted in the theoretically expected linear increase in plate count from 20,000 to 59,000. A maximum plate number of 81,000 was realized using a 600mm long (coupled) column at 2600bar. Viscous-heating effects were diminished by insulating coupled columns and applying an intermediate-cooling strategy in a forced-air oven. PMID:24797393

  1. Automated hydrophobic interaction chromatography column selection for use in protein purification.

    PubMed

    Murphy, Patrick J M; Stone, Orrin J; Anderson, Michelle E

    2011-01-01

    In contrast to other chromatographic methods for purifying proteins (e.g. gel filtration, affinity, and ion exchange), hydrophobic interaction chromatography (HIC) commonly requires experimental determination (referred to as screening or "scouting") in order to select the most suitable chromatographic medium for purifying a given protein (1). The method presented here describes an automated approach to scouting for an optimal HIC media to be used in protein purification. HIC separates proteins and other biomolecules from a crude lysate based on differences in hydrophobicity. Similar to affinity chromatography (AC) and ion exchange chromatography (IEX), HIC is capable of concentrating the protein of interest as it progresses through the chromatographic process. Proteins best suited for purification by HIC include those with hydrophobic surface regions and able to withstand exposure to salt concentrations in excess of 2 M ammonium sulfate ((NH(4;))(2;)SO(4;)). HIC is often chosen as a purification method for proteins lacking an affinity tag, and thus unsuitable for AC, and when IEX fails to provide adequate purification. Hydrophobic moieties on the protein surface temporarily bind to a nonpolar ligand coupled to an inert, immobile matrix. The interaction between protein and ligand are highly dependent on the salt concentration of the buffer flowing through the chromatography column, with high ionic concentrations strengthening the protein-ligand interaction and making the protein immobile (i.e. bound inside the column) (2). As salt concentrations decrease, the protein-ligand interaction dissipates, the protein again becomes mobile and elutes from the column. Several HIC media are commercially available in pre-packed columns, each containing one of several hydrophobic ligands (e.g. S-butyl, butyl, octyl, and phenyl) cross-linked at varying densities to agarose beads of a specific diameter (3). Automated column scouting allows for an efficient approach for determining

  2. High resolution capillary column development for selective separations in gas chromatography

    SciTech Connect

    Przybyciel, M.

    1985-01-01

    A review of techniques for the preparation of high resolution capillary columns for gas chromatography is presented. Surface roughing, surface deactivation, stationary phase coating, and stationary phase crosslinking are discussed. Criteria for the selection of GC stationary phases and procedures for column evaluation are presented. A method is proposed for the isolation and determination of crude oil contamination in tropical plants and sediments. The method uses Florisil (TM) chromatography for the simultaneous clean-up and fractionation of aliphatic and aromatic hydrocarbons. Crosslinked SE-54 fused silica capillary columns prepared in our laboratory were employed for all GC separations. Mass spectrometry was used to help locate and identify specific oil components despite the intense background of the chromatogram. Crude oil components were identified in extracts of mangrove plant samples collected from the Peck Slip oil spill site at Media Munda, Puerto Rico. Crude oil components were also identified in sediment samples from controlled oil spill of Prudhoe Bay oil at Laguna de Chiriqui, Panama.

  3. In-column ATR-FTIR spectroscopy to monitor affinity chromatography purification of monoclonal antibodies

    NASA Astrophysics Data System (ADS)

    Boulet-Audet, Maxime; Kazarian, Sergei G.; Byrne, Bernadette

    2016-07-01

    In recent years many monoclonal antibodies (mAb) have entered the biotherapeutics market, offering new treatments for chronic and life-threatening diseases. Protein A resin captures monoclonal antibody (mAb) effectively, but the binding capacity decays over repeated purification cycles. On an industrial scale, replacing fouled Protein A affinity chromatography resin accounts for a large proportion of the raw material cost. Cleaning-in-place (CIP) procedures were developed to extend Protein A resin lifespan, but chromatograms cannot reliably quantify any remaining contaminants over repeated cycles. To study resin fouling in situ, we coupled affinity chromatography and Fourier transform infrared (FTIR) spectroscopy for the first time, by embedding an attenuated total reflection (ATR) sensor inside a micro-scale column while measuring the UV 280 nm and conductivity. Our approach quantified the in-column protein concentration in the resin bed and determined protein conformation. Our results show that Protein A ligand leached during CIP. We also found that host cell proteins bound to the Protein A resin even more strongly than mAbs and that typical CIP conditions do not remove all fouling contaminants. The insights derived from in-column ATR-FTIR spectroscopic monitoring could contribute to mAb purification quality assurance as well as guide the development of more effective CIP conditions to optimise resin lifespan.

  4. In-column ATR-FTIR spectroscopy to monitor affinity chromatography purification of monoclonal antibodies

    PubMed Central

    Boulet-Audet, Maxime; Kazarian, Sergei G.; Byrne, Bernadette

    2016-01-01

    In recent years many monoclonal antibodies (mAb) have entered the biotherapeutics market, offering new treatments for chronic and life-threatening diseases. Protein A resin captures monoclonal antibody (mAb) effectively, but the binding capacity decays over repeated purification cycles. On an industrial scale, replacing fouled Protein A affinity chromatography resin accounts for a large proportion of the raw material cost. Cleaning-in-place (CIP) procedures were developed to extend Protein A resin lifespan, but chromatograms cannot reliably quantify any remaining contaminants over repeated cycles. To study resin fouling in situ, we coupled affinity chromatography and Fourier transform infrared (FTIR) spectroscopy for the first time, by embedding an attenuated total reflection (ATR) sensor inside a micro-scale column while measuring the UV 280 nm and conductivity. Our approach quantified the in-column protein concentration in the resin bed and determined protein conformation. Our results show that Protein A ligand leached during CIP. We also found that host cell proteins bound to the Protein A resin even more strongly than mAbs and that typical CIP conditions do not remove all fouling contaminants. The insights derived from in-column ATR-FTIR spectroscopic monitoring could contribute to mAb purification quality assurance as well as guide the development of more effective CIP conditions to optimise resin lifespan. PMID:27470880

  5. In-column ATR-FTIR spectroscopy to monitor affinity chromatography purification of monoclonal antibodies.

    PubMed

    Boulet-Audet, Maxime; Kazarian, Sergei G; Byrne, Bernadette

    2016-01-01

    In recent years many monoclonal antibodies (mAb) have entered the biotherapeutics market, offering new treatments for chronic and life-threatening diseases. Protein A resin captures monoclonal antibody (mAb) effectively, but the binding capacity decays over repeated purification cycles. On an industrial scale, replacing fouled Protein A affinity chromatography resin accounts for a large proportion of the raw material cost. Cleaning-in-place (CIP) procedures were developed to extend Protein A resin lifespan, but chromatograms cannot reliably quantify any remaining contaminants over repeated cycles. To study resin fouling in situ, we coupled affinity chromatography and Fourier transform infrared (FTIR) spectroscopy for the first time, by embedding an attenuated total reflection (ATR) sensor inside a micro-scale column while measuring the UV 280 nm and conductivity. Our approach quantified the in-column protein concentration in the resin bed and determined protein conformation. Our results show that Protein A ligand leached during CIP. We also found that host cell proteins bound to the Protein A resin even more strongly than mAbs and that typical CIP conditions do not remove all fouling contaminants. The insights derived from in-column ATR-FTIR spectroscopic monitoring could contribute to mAb purification quality assurance as well as guide the development of more effective CIP conditions to optimise resin lifespan. PMID:27470880

  6. Tailoring the macroporous structure of monolithic silica-based capillary columns with potential for liquid chromatography.

    PubMed

    Laschober, Stefan; Sulyok, Michael; Rosenberg, Erwin

    2007-03-01

    The present work aims at the optimisation of the synthesis of methyl-silsesquioxane monolithic capillary columns using a sol-gel based protocol. The influence of reaction conditions such as temperature, reaction mixture composition and catalyst concentration has been examined. The morphology of the products was studied by scanning electron microscopy and nitrogen adsorption. Monolithic capillary columns were obtained with a skeleton-like structure with open pores. Pore diameters vary from 0.8 to 15 microm, diameters of the xerogel network vary from 0.4 to 12 microm, respectively. Specific surface areas up to 334 m2/g have been observed, however, many materials did not possess areas above few m2/g which represents the limit of detection of the nitrogen porosimetry measurements. Excellent adhesion to the capillary wall was observed in all cases, and drying was possible at ambient conditions without the formation of cracks. PMID:17241639

  7. Revisiting the Separation of Ferrocene and Acetylferrocene by Adsorption Chromatography: Adding a Third Component

    ERIC Educational Resources Information Center

    Hwa, Rebecca; Weizman, Haim

    2007-01-01

    The separation of ferrocene and acetylferrocene by column chromatography is a widely used experiment in undergraduate organic labs. The experiment was expanded into a three-component mixture to increase the challenge of the experiment and to make TLC analysis necessary. (Contains 2 figures.)

  8. Determination of picogram nitroglycerin plasma concentrations using capillary gas chromatography with on-column injection.

    PubMed

    Noonan, P K; Kanfer, I; Riegelman, S; Benet, L Z

    1984-07-01

    A specific, sensitive, and precise capillary gas chromatographic (GC) assay capable of analyzing picogram concentrations of nitroglycerin in human plasma was developed. The analytical procedure involves a double extraction of 1 mL of plasma with pentane, after the addition of internal standard (1 ng of 2,6-dinitrotoluene), followed by evaporation and reconstitution in 50 microL of heptane. The extract (1 microL) was injected onto a capillary column using the on-column injection technique. The GC oven temperature was programmed from 120 degrees C to 180 degrees C at a rate of 5 degrees C/min. The oven temperature was then programmed to 250 degrees C and was maintained for 10 min. The nitroglycerin and internal standard retention times were 8.6 and 11.4 min, respectively. The position of the end of the capillary column inside the detector is a critical determinant of sensitivity: the column exit must be positioned such that nitroglycerin adsorption to the detector is minimized (i.e., sensitivity maximized). The assay limit of quantitation was 25 pg/mL (CV = 7.6%) using 1 mL of plasma. This GC assay, specific for nitroglycerin in the presence of its metabolites, isosorbide dinitrate, and several other drugs, may be used to quantitate plasma levels obtained after therapeutic nitroglycerin doses. PMID:6432997

  9. Extraction of antibiotic zwittermicin A from Bacillus thuringiensis by macroporous resin and silica gel column chromatography.

    PubMed

    Hao, Zaibin; Yan, Li; Liu, Jianguo; Song, Fuping; Zhang, Jie; Li, Xia

    2015-01-01

    To establish a production process capable of providing refined zwittermicin A (ZwA) on a large scale, the macroporous resin and silica gel column chromatography were used to separate and purify the antibiotic ZwA from the fermentation broth of Bacillus thuringiensis HD-1. The result of high-performance liquid chromatography-mass spectrometry after purification suggests that the samples of ZwA were of high purity, 89%, and the average yield was 20 mg L(-1). Erwinia herbicola LS005, Escherichia coli, Staphylococcus aureus, and Bacillus subtilis were used to assess the toxicity of ZwA. The antibiotic had strong antibacterial activity against E. herbicola LS005 and a color reaction with ninhydrin. PMID:25099664

  10. Evaluation of expanded bed adsorption chromatography for extraction of prothrombin complex from Cohn Supernatant I.

    PubMed

    McCann, Karl B; Gomme, Peter T; Wu, John; Bertolini, Joseph

    2008-07-01

    This study evaluated the feasibility of substituting expanded bed adsorption (EBA) chromatography for an existing chromatographic purification process for the isolation of prothrombin complex concentrate (PCC) from Cohn Supernatant I. The EBA chromatography (Streamline) resins were compared to the current DEAE-cellulose resin for the extraction of PCC from Cohn SNI. EBA chromatography resins efficiently bound PCC from Cohn SNI at a significantly higher flow rate of up to 300 cm/h compared to 30 cm/h for the current DEAE-cellulose process. Composition and yield of the recovered PCC reflected the elution conditions used. The results indicate that EBA chromatography could be used to efficiently produce PCC comparable to existing products. PMID:18329287

  11. Determination of free bile acids in pharmaceutical preparations by packed column supercritical fluid chromatography.

    PubMed

    Scalia, S; Games, D E

    1993-01-01

    A method was developed for the baseline separation of common free bile acids by supercritical fluid chromatography. A phenylbonded silica column, with UV detection at 210 nm, and carbon dioxide modified with methanol as the mobile phase were used. The influence of the stationary phase, modifier concentration, temperature, column pressure, and modifier identity on retention was studied. The separation obtained is at least eight times faster than those achieved for similar mixtures by the existing chromatographic techniques. This new procedure is applicable to the assay of ursodeoxycholic acid and chenodeoxycholic acid in capsule and tablet formulations. Individual dosage forms were disintegrated in methanol and an aliquot of the resulting suspension was filtered for the supercritical fluid chromatographic analysis. The method is rapid, accurate, and reproducible. PMID:8429490

  12. Application of Pre-Column Labeling Liquid Chromatography for Canine Plasma-Free Amino Acid Analysis.

    PubMed

    Azuma, Kazuo; Hirao, Yoshiko; Hayakawa, Yoshihiro; Murahata, Yusuke; Osaki, Tomohiro; Tsuka, Takeshi; Imagawa, Tomohiro; Okamoto, Yoshiharu; Ito, Norihiko

    2016-01-01

    Plasma-free amino acid (PFAA) levels are a useful metric for diagnosing cancer and providing a prognosis. However, the use of analysis of PFAA levels has been limited in the veterinary medicine field. We addressed the application of liquid chromatography (LC) using a pre-column labeling technique for analysis of canine PFAA levels. This method significantly shortened the analysis time relative to conventional methods. No diurnal fluctuations were detected at 9:00 AM in most PFAA levels, and food intake increased the levels of some PFAAs, including valine, leucine, tyrosine, phenylalanine, and proline. These results indicate that LC with pre-column labeling is useful for measuring canine PFAA levels, for which time of day and interval after food intake must be taken into consideration. PMID:26771650

  13. Electrochemically-modulated liquid chromatography (EMLC): Column design, retention processes, and applications

    SciTech Connect

    Ting, E.Y.

    1997-10-08

    This work describes the continued development of a new separation technique, electrochemically-modulated liquid chromatography (EMLC), from column design, retention mechanisms to pharmaceutical applications. The introduction section provides a literature review of the technique as well as a brief overview of the research in each of the chapters. This section is followed by four chapters which investigate the issues of EMLC column design, the retention mechanism of monosubstituted aromatic compounds, and the EMLC-based applications to two important classes of pharmaceutical compounds (i.e., corticosteroids and benzodiazepines). These four sections have been removed to process separately for inclusion on the database. The dissertation concludes with a general summary, a prospectus, and a list of references cited in the General Introduction. 32 refs.

  14. Packed column supercritical fluid chromatography of sodium stearyl fumarate aqueous suspension.

    PubMed

    Gyllenhaal, Olle

    2006-03-01

    A method for the determination of sodium stearyl fumarate aqueous suspension is described. This straightforward method is based on homogenisation of the sample, dilution of a known aliquot with methanol to a suitable clear solution and mixing with an internal standard; (S)-naproxen. Separation and quantification is performed by packed column supercritical fluid chromatography on a commercial tartaric acid network polymeric column (tertbutylbenzoyl) with UV-detection at 214 nm. The precision of the presented method upon repeated analysis of a 20 mg/ml suspension is 0.5% (n = 8), and the yield is near 100%. Less than 5 min is required for the chromatographic separation with a resolution of about 3 to the internal standard. With some modification of the chromatographic conditions water samples can also be analysed. PMID:16174559

  15. Using the column wall itself as resistive heater for fast temperature gradients in liquid chromatography.

    PubMed

    De Pauw, Ruben; Pursch, Matthias; Desmet, Gert

    2015-11-13

    A new system is proposed for applying fast temperature gradients in liquid chromatography. It consists of a 0.7 mm × 150 mm fused-silica column coated with a 50 μm Nickel-layer, which is connecting with a power source and a temperature control system to perform fast and reproducible temperature gradients using the column wall itself as a resistive heater. Applying a current of 4A and passive cooling results in a maximal heating and cooling rate of, respectively, 71 and -21 °C/min. Multi-segment temperature gradients were superimposed on mobile phase gradients to enhance the selectivity for three sets of mixtures (pharmaceutical compounds, a highly complex mixture and an insecticide sample). This resulted in a higher peak count or better selectivities for the various mixtures. PMID:26476853

  16. Application of Pre-Column Labeling Liquid Chromatography for Canine Plasma-Free Amino Acid Analysis

    PubMed Central

    Azuma, Kazuo; Hirao, Yoshiko; Hayakawa, Yoshihiro; Murahata, Yusuke; Osaki, Tomohiro; Tsuka, Takeshi; Imagawa, Tomohiro; Okamoto, Yoshiharu; Ito, Norihiko

    2016-01-01

    Plasma-free amino acid (PFAA) levels are a useful metric for diagnosing cancer and providing a prognosis. However, the use of analysis of PFAA levels has been limited in the veterinary medicine field. We addressed the application of liquid chromatography (LC) using a pre-column labeling technique for analysis of canine PFAA levels. This method significantly shortened the analysis time relative to conventional methods. No diurnal fluctuations were detected at 9:00 AM in most PFAA levels, and food intake increased the levels of some PFAAs, including valine, leucine, tyrosine, phenylalanine, and proline. These results indicate that LC with pre-column labeling is useful for measuring canine PFAA levels, for which time of day and interval after food intake must be taken into consideration. PMID:26771650

  17. Measurement of bromate in bread by liquid chromatography with post-column flow reactor detection.

    PubMed

    Himata, K; Noda, M; Ando, S; Yamada, Y

    2000-01-01

    This method is suitable for the determination of bromate residues in a variety of baked goods. The peer-verified method trial was performed on white bread, multigrain bread, and coffee cake spiked with known levels of potassium bromate. The analytical portion is extracted with deionized water to remove bromate from the bulk of the baked product. The aqueous extract is carried through a series of steps to remove co-extractives that would interfere with the liquid chromatography (LC) in the determinative step or hasten the deterioration of the LC column. The extract is filtered before passing it through a reversed-phase solid-phase extraction (SPE) column and a cation-exchange column in the silver form to remove lipids and chloride, respectively. Ultrafiltration is then used to remove proteins with molecular weights of >30,000 daltons. Finally, a cation-exchange column in the sodium form is used to remove silver ions from the extract. The determinative step uses LC with a reversed-phase column and an ion-pairing agent in the mobile phase. Detection is based on the post-column reaction of bromate with o-dianisidine to form an oxidation product that is quantitated spectrophotometrically at 450 nm. Overall agreement between the submitting and peer laboratories was quite good. For bromate levels of 10-52 ppb, overall mean recoveries were 76.9 and 78.8% for the submitting and peer laboratories, respectively. The standard deviations were higher for the results of the peer laboratory, probably because of the generally higher level of baseline noise present in the chromatograms. The results demonstrate that the method provides adequate accuracy with low-fat as well as high-fat foods. Bromate at levels as low as 5 ppb (ng/g) can be detected with the method. PMID:10772172

  18. Analysis of isoamylase debranched starches with size exclusion chromatography utilizing PFG columns.

    PubMed

    Ciric, Jelena; Woortman, Albert J J; Loos, Katja

    2014-11-01

    Debranched starches were tested with a previously developed method for size exclusion chromatography (SEC) with multi detection utilizing different columns than usually used for the separation of starch in DMSO. A number of debranched starches were analyzed. This system allows good separation of amylose and amylopectin after debranching of starch, and provides quantitative information on the amylose content. Additionally molar mass versus hydrodynamic radii (Rh) distributions of various debranched starches show that the debranching was not 100% and that the differences in the structure of various starches can be followed. PMID:25129767

  19. Simple, specific analysis of organophosphorus and carbamate pesticides in sediments using column extraction and gas chromatography

    USGS Publications Warehouse

    Belisle, A.A.; Swineford, D.M.

    1988-01-01

    A simple, specific procedure was developed for the analysis of organophosphorus and carbamate pesticides in sediment. The wet soil was mixed with anhydrous sodium sulfate to bind water and the residues were column extracted in acetone:methylene chloride (1:l,v/v). Coextracted water was removed by additional sodium sulfate packed below the sample mixture. The eluate was concentrated and analyzed directly by capillary gas chromatography using phosphorus and nitrogen specific detectors. Recoveries averaged 93 % for sediments extracted shortly after spiking, but decreased significantly as the samples aged.

  20. Evaluation of microextraction/capillary column gas chromatography for monitoring industrial outfalls

    SciTech Connect

    Thielen, D.R.; Olsen, G.; Davis, A.; Bajor, E.; Stefanovski, J.; Chodkowski, J.

    1987-01-01

    Microextraction and capillary-column gas chromatography techniques are applied to plant discharge streams for repetitive wastewater discharge permit analyses. This combination allows the analyst to reduce sample preparation since microextraction replaces both purge-and-trap for volatiles and microextraction for semi-volatiles. An additional advantage is the elimination of a concentration step, which is ,ften a major contributor to low method recoveries. The overall procedure is shown to be more precise than purge-and-trap but slightly less precise than conventional extraction. The results of each method are shown to be equivalent.

  1. Inverse gas chromatography. V - Computer simulation of diffusion processes on the column

    NASA Technical Reports Server (NTRS)

    Hattam, Paul; Munk, Petr

    1988-01-01

    The elution behavior of low molecular weight probes on inverse gas chromatography (IGC) columns is simulated using a computer. The IGC model is based on a polymer stationary phase of uniform thickness with a nonnegligible resitance to probe penetration. Three characteristic numbers are found to determine the whole process: Z(p) characterizing the distribution of the probe between phases, Z(f) describing the diffusion in the polymer phase, and Z(g) related to diffusion in the gaseous phase. For situations when Z(p)/Z(f) is less than 2, the standard evaluation procedures are virtually useless. The actual behavior of such systems is described.

  2. Blind column selection protocol for two-dimensional high performance liquid chromatography.

    PubMed

    Burns, Niki K; Andrighetto, Luke M; Conlan, Xavier A; Purcell, Stuart D; Barnett, Neil W; Denning, Jacquie; Francis, Paul S; Stevenson, Paul G

    2016-07-01

    The selection of two orthogonal columns for two-dimensional high performance liquid chromatography (LC×LC) separation of natural product extracts can be a labour intensive and time consuming process and in many cases is an entirely trial-and-error approach. This paper introduces a blind optimisation method for column selection of a black box of constituent components. A data processing pipeline, created in the open source application OpenMS®, was developed to map the components within the mixture of equal mass across a library of HPLC columns; LC×LC separation space utilisation was compared by measuring the fractional surface coverage, fcoverage. It was found that for a test mixture from an opium poppy (Papaver somniferum) extract, the combination of diphenyl and C18 stationary phases provided a predicted fcoverage of 0.48 and was matched with an actual usage of 0.43. OpenMS®, in conjunction with algorithms designed in house, have allowed for a significantly quicker selection of two orthogonal columns, which have been optimised for a LC×LC separation of crude extractions of plant material. PMID:27154652

  3. Ionic liquid-based zwitterionic organic polymer monolithic column for capillary hydrophilic interaction chromatography.

    PubMed

    Wang, Tingting; Chen, Yihui; Ma, Junfeng; Zhang, Xiaodan; Zhang, Lihua; Zhang, Yukui

    2015-08-21

    In the current study, a novel ionic liquid-based zwitterionic organic polymer monolithic column was developed by copolymerizing 1-vinyl-3-(butyl-4-sulfonate) imidazolium, acrylamide and N,N'-methylenebisacrylamide in a quaternary porogenic solvent consisting of formamide, dimethyl sulphoxide, polyethylene glycol 8000 and polyethylene glycol 10,000 for capillary hydrophilic interaction chromatography. The monolithic stationary phase was optimized by adjusting the amount of monomer in the polymerization solution along with the composition of porogenic solvent. The optimized monolith exhibited excellent selectivity and favorable retention for nucleosides and benzoic acid derivatives. The primary factors affecting the separation efficiency of the monolithic column (including acetonitrile content, pH, and buffer salt concentration in the mobile phase) have been thoroughly evaluated. Excellent reproducibility of the retention times for five nucleosides was achieved, with relative standard deviations of run-to-run (n = 3), column-to-column (n = 3) and batch-to-batch (n = 3) in the range of 0.18-0.48%, 2.33-4.20% and 3.07-6.50%, respectively. PMID:26114194

  4. Surfactant-Bound Monolithic Columns for Separation of Proteins in Capillary High Performance Liquid Chromatography

    PubMed Central

    Gu, Congying; He, Jun; Jia, Jinping; Fang, Nenghu; Simmons, Robert; Shamsi, Shahab A.

    2011-01-01

    A surfactant bound monolithic stationary phase based on the co-polymerization of 11-acrylamino-undecanoic acid (AAUA) is designed for capillary high performance liquid chromatography (HPLC). Using D-optimal design, the effect of the polymerization mixture (concentrations of monomer, crosslinker and porogens) on the chromatographic performance (resolution and analysis time) of the AAUA-EDMA monolithic column was evaluated. The polymerization mixture was optimized using three proteins as model test solutes. The D-optimal design indicates a strong dependence of chromatographic parameters on the concentration of porogens (1,4-butanediol and water) in the polymerization mixture. Optimized solutions for fast separation and high resolution separation, respectively, were obtained using the proposed multivariate optimization. Differences less than 6.8% between the predicted and the experimental values in terms of resolution and retention time indeed confirmed that the proposed approach is practical. Using the optimized column, fast separation of proteins could be obtained in 2.5 min, and a tryptic digest of myoglobin was successfully separated on the high resolution column. The physical properties (i.e. morphology, porosity and permeability) of the optimized monolithic column were thoroughly investigated. It appears that this surfactant-bound monolith may have a great potential as a new generation of capillary HPLC stationary phase. PMID:20031139

  5. Synthesis and characterization of a cellular membrane affinity chromatography column containing histamine 1 and P2Y1 receptors: A multiple G-protein coupled receptor column

    PubMed Central

    Moaddel, Ruin; Musyimi, Harrison K.; Sanghvi, Mitesh; Bashore, Charlene; Frazier, Chester R.; Khadeer, Mohammad; Bhatia, Prateek; Wainer, Irving W.

    2015-01-01

    A cellular membrane affinity chromatography (CMAC) column has been created using cellular membrane fragments from a 1321N1 cell line stably transfected with the P2Y1 receptor. The CMAC(1321N1P2Y1) column contained functional P2Y1 and histamine 1 receptors, which independently bound receptor-specific ligands. The data obtained with the CMAC(1321N1P2Y1) column demonstrate that multiple-G-protein coupled receptor (GPCR) columns can be developed and used to probe interactions with the immobilized receptors and that endogenously expressed GPCRs can be used to create CMAC columns. The results also establish that the histamine 1 receptor can be immobilized with retention of ligand-specific binding. PMID:19608372

  6. Simulation of the dynamic packing behavior of preparative chromatography columns via discrete particle modeling.

    PubMed

    Dorn, Martin; Hekmat, Dariusch

    2016-03-01

    Preparative packed-bed chromatography using polymer-based, compressible, porous resins is a powerful method for purification of macromolecular bioproducts. During operation, a complex, hysteretic, thus, history-dependent packed bed behavior is often observed but theoretical understanding of the causes is limited. Therefore, a rigorous modeling approach of the chromatography column on the particle scale has been made which takes into account interparticle micromechanics and fluid-particle interactions for the first time. A three-dimensional deterministic model was created by applying Computational Fluid Dynamics (CFD) coupled with the Discrete Element Method (DEM). The column packing behavior during either flow or mechanical compression was investigated in-silico and in laboratory experiments. A pronounced axial compression-relaxation profile was identified that differed for both compression strategies. Void spaces were clearly visible in the packed bed after compression. It was assumed that the observed bed inhomogeneity was because of a force-chain network at the particle scale. The simulation satisfactorily reproduced the measured behavior regarding packing compression as well as pressure-flow dependency. Furthermore, the particle Young's modulus and particle-wall friction as well as interparticle friction were identified as crucial parameters affecting packing dynamics. It was concluded that compaction of the chromatographic bed is rather because of particle rearrangement than particle deformation. © 2015 American Institute of Chemical Engineers Biotechnol. Prog., 32:363-371, 2016. PMID:26588806

  7. [Determination of major carbonyls in mainstream smoke by rapid column high performance liquid chromatography].

    PubMed

    Huang, Yun; Wang, Yigeng; Miao, Mingming; Zhao, Qihua; Yang, Guangyu

    2007-03-01

    Abstract: The determination of major carbonyl compounds in mainstream cigarette smoke by rapid column high performance liquid chromatography was investigated. The cigarette smoke was collected using a Cambridge filter treated with acidic solution of 2, 4-dinitrophenyl-hydrazine. Formaldehyde, acetaldehyde, acetone, acrolein, propionaldehyde, crotonaldehyde, 2-butanone and butyraldehyde were extracted from the Cambridge filter with 50 mL of 2% pyridine acetonitrile solution. The carbonyl compounds in samples were separated on a ZORBAX Stable Bound rapid column (50 mm x 4. 6 mm, 1. 8 microm) in approximately seven minutes and then determined by high performance liquid chromatography with a diode array detector. The average recoveries were in the range of 89. 1% to 99. 2% and the relative standard deviations (RSDs) were generally below 6. 0%. The eight carbonyl compounds in the mainstream smoke of five brands of cigarettes were determined using this method. This method is faster, simpler and consumes less solvent. It is suitable for rapid analysis of carbonyl compounds in mainstream cigarette smoke. PMID:17580693

  8. Reaction flow chromatography for rapid post column derivatisations: the analysis of antioxidants in natural products.

    PubMed

    Camenzuli, M; Ritchie, H J; Dennis, G R; Shalliker, R A

    2013-08-16

    The analysis of antioxidants from complex samples is conveniently achieved using liquid chromatography, which provides sample fraction, coupled with an on-line antioxidant assay, which provides detection. One particularly useful on-line antioxidant assay that has routinely been coupled with HPLC involves the diphenylpicrylhydrazyl radical (DPPH), which provides a positive test for phenolic antioxidants through a decolorisation of the DPPH reagent. A limitation of this assay, however, is the need to employ a reaction coil, which is often large with respect to the peak volume, consequently adding substantial band broadening to the separation. In this study we introduce a new concept that can be employed for systems requiring post column derivatisations, such as the DPPH assay. We have termed this 'reaction flow' chromatography, whereby, the derivatisation reagent can be added directly into one of the outlet ports of a parallel segmented flow column. Subsequently, the mixing between the derivatising reagent and the solute is very efficient removing the need to employ reaction coils. The concept is tested here using the DPPH assay for the analysis of antioxidants in samples derived from natural origin. PMID:23849586

  9. Behavior of short silica monolithic columns in high pressure gas chromatography.

    PubMed

    Maniquet, Adrien; Bruyer, Nicolas; Raffin, Guy; Baco-Antoniali, Franck; Demesmay, Claire; Dugas, Vincent; Randon, Jérôme

    2016-08-19

    In order to analyze light hydrocarbons mixtures with silica monolithic columns, a conventional gas chromatograph was modified to work with carrier gas pressure as high as 60bar. To understand hydrodynamic flow and retention with short columns (less than 30cm), special attention was required due to the temperature difference between the oven area and the FID detector which contain a significant length of the column. Efficiency and selectivity using various carrier gases (helium, nitrogen and carbon dioxide) at different inlet pressure for different oven temperature were studied. Carrier gas nature was a very significant parameter: on one side, linked to adsorption mechanism for gases like nitrogen and carbon dioxide onto the stationary phase modifying retention and selectivity, on the other side in relation to the minimum theoretical plate height which was as low as 15μm (66 000 platem(-1)) using carbon dioxide as carrier gas. The chromatographic system was then used to separate methane, ethane, ethylene, acetylene, propane, cyclopropane, and butane in less than 30s. PMID:27432790

  10. Column study of chromium(VI) adsorption from electroplating industry by coconut coir pith.

    PubMed

    Suksabye, Parinda; Thiravetyan, Paitip; Nakbanpote, Woranan

    2008-12-15

    The removal of Cr(VI) from electroplating wastewater by coir pith was investigated in a fixed-bed column. The experiments were conducted to study the effect of important parameters such as bed depth (40-60cm) and flow rate (10-30ml min(-1)). At 0.05 C(t)/C(0), the breakthrough volume increased as flow rate decreased or a bed depth increased due to an increase in empty bed contact time (EBCT). The bed depth service time model (BDST) fit well with the experimental data in the initial region of the breakthrough curve, while the simulation of the whole curve using non-linear regression analysis was effective using the Thomas model. The adsorption capacity estimated from the BDST model was reduced with increasing flow rate, which was 16.40mg cm(-3) or 137.91mg Cr(VI)g(-1) coir pith for the flow rates of 10ml min(-1) and 14.05mg cm(-3) or 118.20mg Cr(VI)g(-1) coir pith for the flow rates of 30ml min(-1). At the highest bed depth (60cm) and the lowest flow rate (10mlmin(-1)), the maximum adsorption reached 201.47mg Cr(VI)g(-1) adsorbent according to the Thomas model. The column was regenerated by eluting chromium using 2M HNO(3) after adsorption studies. The desorption of Cr(III) in each of three cycles was about 67-70%. The desorption of Cr(III) in each cycle did not reach 100% due to the fact that Cr(V) was present through the reduction of Cr(VI), and was still in coir pith, possibly bound to glucose in the cellulose part of coir pith. Therefore, the Cr(V) complex cannot be desorbed in solution. The evidence of Cr(V) signal was observed in coir pith, alpha-cellulose and holocellulose extracted from coir pith using electron spin resonance (ESR). PMID:18406058

  11. Advantages of core-shell particle columns in Sequential Injection Chromatography for determination of phenolic acids.

    PubMed

    Chocholouš, Petr; Vacková, Jana; Srámková, Ivana; Satínský, Dalibor; Solich, Petr

    2013-01-15

    Currently, for Sequential Injection Chromatography (SIC), only reversed phase C18 columns have been used for chromatographic separations. This article presents the first use of three different stationary phases: three core-shell particle-packed reversed phase columns in flow systems. The aim of this work was to extend the chromatographic capabilities of the SIC system. Despite the particle-packed columns reaching system pressures of ≤ 610 PSI, their conditions matched those of a commercially produced and optimised SIC system (SIChrom™ (FIAlab(®), USA)) with a 8-port high-pressure selection valve and medium-pressure Sapphire™ syringe pump with a 4 mL reservoir and maximum system pressure of ≤ 1000 PSI. The selectivity of each of the tested columns, Ascentis(®) Express RP-Amide, Ascentis(®) Express Phenyl-Hexyl and Ascentis(®) Express C18 (30 mm × 4.6mm, core-shell particle size 2.7 μm), was compared by their ability to separate seven phenolic acids that are secondary metabolite substances widely distributed in plants. The separations of all of the components were performed by isocratic elution using binary mobile phases composed of acetonitrile and 0.065% phosphoric acid at pH 2.4 (a specific ratio was used for each column) at a flow-rate of 0.60 mL/min. The volume of the mobile phase was 3.8 mL for each separation. The injection volume of the sample was 10 μL for each separation. The UV detection wavelengths were set to 250, 280 and 325 nm. The RP-Amide column provided the highest chromatographic resolution and allowed for complete baseline separation of protocatechuic, syringic, vanillic, ferulic, sinapinic, p-coumaric and o-coumaric acids. The Phenyl-Hexyl and C18 columns were unable to completely separate the tested mixture, syringic and vanillic acid and ferulic and sinapinic acids could not be separated from one another. The analytical parameters were a LOD of 0.3 mg L(-1), a LOQ of 1.0 mg L(-1), a calibration range of 1.0-50.0 (100.0) mg L(-1

  12. Evaluating the long-term performance of low-cost adsorbents using small-scale adsorption column experiments.

    PubMed

    Callery, O; Healy, M G; Rognard, F; Barthelemy, L; Brennan, R B

    2016-09-15

    This study investigated a novel method of predicting the long-term phosphorus removal performance of large-scale adsorption filters, using data derived from short-term, small-scale column experiments. The filter media investigated were low-cost adsorbents such as aluminum sulfate drinking water treatment residual, ferric sulfate drinking water treatment residual, and fine and coarse crushed concretes. Small-bore adsorption columns were loaded with synthetic wastewater, and treated column effluent volume was plotted against the mass of phosphorus adsorbed per unit mass of filter media. It was observed that the curve described by the data strongly resembled that of a standard adsorption isotherm created from batch adsorption data. Consequently, it was hypothesized that an equation following the form of the Freundlich isotherm would describe the relationship between filter loading and media saturation. Moreover, the relationship between filter loading and effluent concentration could also be derived from this equation. The proposed model was demonstrated to accurately predict the performance of large-scale adsorption filters over a period of up to three months with a very high degree of accuracy. Furthermore, the coefficients necessary to produce said model could be determined from just 24 h of small-scale experimental data. PMID:27295617

  13. Direct coupling of packed column supercritical fluid chromatography to continuous corona discharge ion mobility spectrometry.

    PubMed

    Rahmanian, A; Ghaziaskar, H S; Khayamian, T

    2013-01-11

    In this study, packed column supercritical fluid chromatography (SFC) was directly coupled to a continuous corona discharge (CD) ion mobility spectrometer (IMS) with several modifications. The main advantage of the developed detector is its capability to introduce full column effluent up to 2000 mL min(-1) CO(2) gas directly into the IMS cell relative to 40 mL min(-1) CO(2) gas as a maximum tolerance, reported for the previous IMS detectors. This achievement was made possible because of using corona discharge instead of (63)Ni as an ionization source and locating the inlet and outlet of the CO(2) gas in the counter electrode of the CD in opposite direction. In addition, a heated interface was placed between back pressure regulator (BPR) and the IMS cell to heat the output of the BPR for introducing sample as the gas phase into the IMS cell. Furthermore, a make-up methanol flow was introduced between the column outlet and BPR to provide a more uniform flow through the BPR and also to prevent freezing and deposition of the analytes in the BPR. The performance of the SFC-CD-IMS was evaluated by analysis of testosterone, medroxyprogesterone, caffeine, and theophylline as test compounds and figures of merit for these compounds have been calculated. PMID:23261285

  14. Separation of uremic toxins from urine with resorcinarene-based ion chromatography columns.

    PubMed

    Panahi, Tayyebeh; Weaver, Douglas J; Lamb, John D; Harrison, Roger G

    2015-01-01

    People with chronic kidney disease suffer from uremic toxins which accumulate in their bodies. Detection and quantification of uremic toxins help diagnose kidney problems and start patient care. The aim of this research was to seek a new method to assist this diagnosis by trace level detection and separation of guanidine containing uremic toxins in water and urine. To detect and quantify the uremic toxins, new stationary phases for ion chromatography (IC) columns based on glutamic acid functionalized resorcinarenes bound to divinylbenzene macroporous resin were prepared. The new column packing material afforded separation of the five compounds: guanidinoacetic acid, guanidine, methylguanidine, creatinine, and guanidinobenzoic acid in 30min. Peak resolutions ranged from 7.6 to 1.3. Gradient elutions at ambient temperature with methanesulfonic acid (MSA) solution as eluent resulted in detection levels in water from 10 to 47ppb and in synthetic urine from 28 to 180ppb. Limits of quantification for the analytes using pulsed amperometric detection were 30-160ppb in water and 93-590ppb in urine. Trace levels of creatinine (1ppm) were detected in the urine of a healthy individual using the columns. PMID:25537175

  15. Retention behavior of hydrophobic organic chemicals as a function of temperature in soil leaching column chromatography.

    PubMed

    Liang, Xinmiao; Xu, Feng; Lin, Bingcheng; Su, Fan; Schramm, Karl-Werner; Kettrup, Antonius

    2002-11-01

    To study the transport mechanism of hydrophobic organic chemicals (HOCs) and the energy change in soil/solvent system, a soil leaching column chromatographic (SLCC) experiment at an environmental temperature range of 20-40 degrees C was carried out, which utilized a reference soil (SP 14696) packed column and a methanol-water (1:4 by volume ratio) eluent. The transport process quickens with the increase of column temperature. The ratio of retention factors at 30 and 40 degrees C (k'30/k'40) ranged from 1.08 to 1.36. The lower enthalpy change of the solute transfer in SLCC (from eluent to soil) than in conventional reversed-phase liquid chromatography (e.g., from eluent to C18) is consistent with the hypothesis that HOCs were dominantly and physically partitioned between solvent and soil. The results were also verified by the linear solvation energy relationships analysis. The chief factor controlling the retention was found to be the solute solvophobic partition, and the second important factor was the solute hydrogen-bond basicity, while the least important factors were the solute polarizability-dipolarity and hydrogen-bond acidity. With the increase of temperature, the contributions of the solute solvophobic partition and hydrogen-bond basicity gradually decrease, and the latter decreases faster than the former. PMID:12430644

  16. Analysis of fifteen estrogen metabolites using packed column supercritical fluid chromatography-mass spectrometry.

    PubMed

    Xu, Xia; Roman, John M; Veenstra, Timothy D; Van Anda, Jennifer; Ziegler, Regina G; Issaq, Haleem J

    2006-03-01

    Packed column supercritical fluid chromatography with tandem mass spectrometry was used for the separation of estrone, estradiol, estriol, 16-epiestriol, 17-epiestriol, 16-ketoestradiol, 16alpha-hydroxyestrone, 2-methoxyestrone, 4-methoxyestrone, 2-hydroxyestrone-3-methyl ether, 2-methoxyestradiol, 4-methoxyestradiol, 2-hydroxyestrone, 4-hydroxyestrone, and 2-hydroxyestradiol. A gradient of methanol in carbon dioxide (0-30% methanol in 15 min, 2% change/min) at a flow rate of 2 mL/min and cyanopropyl silica column connected in series with a diol column, both 2.1 mm i.d. x 150 mm long, packed with 5-mum spherical silica-based particles, resulted in the separation and quantification of all 15 estrogens in less than 10 min. The limit of detection (LOD) and limit of quantitation (LOQ) of this pSFC MS/MS method was determined to be 0.5 (S/N = 3), and 5 pg, respectively. Compared with RP-HPLC MS analysis of the same mixture in terms of speed of analysis and sensitivity, pSFC MS is much faster, 10 versus 70 min, with comparable LOD and LOQ. PMID:16503607

  17. Isolation of human beta-interferon receptor by wheat germ lectin affinity and immunosorbent column chromatographies

    SciTech Connect

    Zhang, Z.Q.; Fournier, A.; Tan, Y.H.

    1986-06-15

    Radioiodinated human beta-interferon-Ser 17 (Betaseron) was reversibly cross-linked to Daudi cells by dithiobis(succinimidylpropionate). The radioactive ligand was cross-linked to three macromolecules forming labeled complexes of apparent Mr values of 130,000, 220,000, and 320,000. Betaseron, human alpha-interferon, human interleukin 2 but not recombinant human gamma-interferon competed with the labeled ligand for binding to these putative receptor(s). Human leukocyte-produced gamma-interferon competed weakly with /sup 125/I-Betaseron for binding to Daudi cells. The Betaseron-receptor complex(es) was purified by passage through a wheat germ lectin column followed by chromatography on an anti-interferon immunosorbent column and semipreparative gel electrophoresis. The cross-linked ligand-receptor complex was shown to be highly purified by sodium dodecyl sulfate and acetic acid:urea:Triton X-100 polyacrylamide gel electrophoresis. It can be dissociated into the labeled Betaseron (Mr = 17,000) ligand and a receptor moiety which has an apparent molecular weight of 110,000. The chromatographic behavior of the ligand-receptor complex on wheat germ lectin column suggests that the receptor is a glycoprotein. The described procedure yielded about 1 microgram of Betaseron receptor from 10(10) Daudi cells, estimated to contain a maximum of about 15 micrograms of the receptor.

  18. Effect of the mobile phase composition on the adsorption behavior of tryptophan in reversed-phase liquid chromatography

    SciTech Connect

    Ahmad, Tarab; Guiochon, Georges A

    2006-03-01

    Single-component adsorption isotherm data of l-tryptophan on a C{sub 18}-bonded silica column were acquired by frontal analysis (FA), with aqueous mobile phases containing 2.5, 5, and 7.5% of acetonitrile (ACN) or 7, 10, 15, and 20% of methanol (MeOH). Most of these isotherms have two inflection points and three different parts. The low and the high concentration parts exhibit langmuirian behavior. The intermediate part exhibits anti-langmuirian behavior. The inflection points shift toward higher concentrations with increasing mobile phase concentration in ACN or MeOH, which causes the differences in the isotherm profiles. The nature of the organic modifier and its concentration affect only the isotherm profile and the numerical values of its parameters, not the nature of the best model, which is the bi-Moreau model in all cases. The isotherm profiles depend on the experimental conditions because they affect the intensity of the adsorbate-adsorbate interactions. Overloaded band profiles of tryptophan were recorded with the seven mobile phase compositions. They were used to determine the best values of the isotherm coefficients by the inverse method (IM) of chromatography. There is an excellent agreement between the values of these parameters obtained by FA and by IM. Increasing the concentration of either ACN or MeOH in the mobile phase causes a slight decrease in the saturation capacities of the low and the high energy sites, and in the adsorption constant of the low energy sites. The adsorption constant of the high energy sites increases with increasing concentration of either solvent or is little affected. The adsorbate-adsorbate interaction constants of both low and high energy sites increase for both solvents. Saturation capacities of the high energy sites are higher for ACN than for MeOH.

  19. Efficiency of short, small-diameter columns for reversed-phase liquid chromatography under practical operating conditions.

    PubMed

    Ma, Yan; Chassy, Alexander W; Miyazaki, Shota; Motokawa, Masanori; Morisato, Kei; Uzu, Hideyuki; Ohira, Masayoshi; Furuno, Masahiro; Nakanishi, Kazuki; Minakuchi, Hiroyoshi; Mriziq, Khaled; Farkas, Tivadar; Fiehn, Oliver; Tanaka, Nobuo

    2015-02-27

    Prototype small-size (1.0mm I.D., 5cm long) columns for reversed-phase HPLC were evaluated in relation to instrument requirements. The performance of three types of columns, monolithic silica and particulate silica (2μm, totally porous and 2.6μm, core-shell particles) was studied in the presence of considerable or minimal extra-column effects, while the detector contribution to band broadening was minimized by employing a small size UV-detector cell (6- or 90nL). A micro-LC instrument having small system volume (<1μL) provided extra-column band variance of only 0.01-0.02μL(2). The three columns generated about 8500 theoretical plates for solutes with retention factor, k>1-3 (depending on the column), in acetonitrile/water mobile phase (65/35=vol/vol) at 0.05mL/min, with the instrument specified above. The column efficiency was lower by up to 30% than that observed with a 2.1mm I.D. commercial column. The small-size columns also provided 8000-8500 theoretical plates for well retained solutes with a commercial ultrahigh-pressure liquid chromatography (UHPLC) instrument when extra-column contributions were minimized. While a significant extra-column effect was observed for early eluting solutes (k<2-4, depending on column) with methanol/water (20/80=vol/vol) as weak-wash solvent, the use of methanol/water=50/50 as wash solvent affected the column efficiency for most analytes. The results suggest that the band compression effect by the weak-wash solvent associated with partial-loop injection may provide a practical means to reducing the extra-column effect for small-size columns, while the use of an instrument with minimum extra-column effect is highly desirable. PMID:25648581

  20. Comprehensive and Reproducible Phosphopeptide Enrichment Using Iron Immobilized Metal Ion Affinity Chromatography (Fe-IMAC) Columns

    PubMed Central

    Ruprecht, Benjamin; Koch, Heiner; Medard, Guillaume; Mundt, Max; Kuster, Bernhard; Lemeer, Simone

    2015-01-01

    Advances in phosphopeptide enrichment methods enable the identification of thousands of phosphopeptides from complex samples. Current offline enrichment approaches using TiO2, Ti, and Fe immobilized metal ion affinity chromatography (IMAC) material in batch or microtip format are widely used, but they suffer from irreproducibility and compromised selectivity. To address these shortcomings, we revisited the merits of performing phosphopeptide enrichment in an HPLC column format. We found that Fe-IMAC columns enabled the selective, comprehensive, and reproducible enrichment of phosphopeptides out of complex lysates. Column enrichment did not suffer from bead-to-sample ratio issues and scaled linearly from 100 μg to 5 mg of digest. Direct measurements on an Orbitrap Velos mass spectrometer identified >7500 unique phosphopeptides with 90% selectivity and good quantitative reproducibility (median cv of 15%). The number of unique phosphopeptides could be increased to more than 14,000 when the IMAC eluate was subjected to a subsequent hydrophilic strong anion exchange separation. Fe-IMAC columns outperformed Ti-IMAC and TiO2 in batch or tip mode in terms of phosphopeptide identification and intensity. Permutation enrichments of flow-throughs showed that all materials largely bound the same phosphopeptide species, independent of physicochemical characteristics. However, binding capacity and elution efficiency did profoundly differ among the enrichment materials and formats. As a result, the often quoted orthogonality of the materials has to be called into question. Our results strongly suggest that insufficient capacity, inefficient elution, and the stochastic nature of data-dependent acquisition in mass spectrometry are the causes of the experimentally observed complementarity. The Fe-IMAC enrichment workflow using an HPLC format developed here enables rapid and comprehensive phosphoproteome analysis that can be applied to a wide range of biological systems. PMID

  1. Gas chromatography using a resistively heated column with mass spectrometric detection for rapid analysis of pyridine released from Bacillus spores.

    PubMed

    Smith, Philip A; MacDonald, Stephen

    2004-05-21

    Gas chromatography using a resistively heated analytical column with full scan electron impact mass spectrometry (EI-MS) was used to detect pyridine generated from heating Bacillus spores in a custom designed furnace inlet, along with gasoline range aromatic (GRA) hydrocarbons representing an environmental contaminant that could interfere with detection of the biologically-derived compound. Gas phase materials from the furnace inlet were collected onto a section of cooled open tubular column, and carrier gas flow was then routed through the trapping column onto the analytical column. Both sections of column were contained within low thermal mass tubular metal sheaths, with each independently and resistively heated allowing rapid temperature ramps and cooling. An analysis time of 2 min resolved spore-derived pyridine from the other organics, and allowed identification by mass spectrum match. Throughput of 20 analyses per hour was shown to be possible with a 1-min column cool-down time between analyses. PMID:15146930

  2. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of organochlorine pesticides and polychlorinated biphenyls in bottom sediment by dual capillary-column gas chromatography with electron-capture detection

    USGS Publications Warehouse

    Foreman, William T.; Connor, Brooke F.; Furlong, Edward T.; Vaught, Deborah G.; Merten, Leslie M.

    1995-01-01

    A method for the determination of 30 individual organochlorine pesticides, total toxaphene, and total polychlorinated biphenyls (PCBs) in bottom sediment is described. The method isolates the pesticides and PCBs by solvent extraction with dichlorobenzene, removes inorganic sulfur, large naturally occurring molecules, and other unwanted interferences by gel permeation chromatography, and further cleans up and class fractionates the extract using adsorption chromatography. The com- pounds then are instrumentally determined using dual capillary-column gas chromatography with electron-capture detection. Reporting limits range from 1 to 5 micrograms per kilogram for 30 individual pesticides, 50 micrograms per kilogram for total PCBs, and 200 micrograms per kilogram for total toxaphene. The method also is designed to allow the simultaneous isolation of 79 other semivolatile organic compounds from the sediment, which are separately quantified using gas chromatography with mass spectrometric detection. The method was developed in support of the U.S. Geological Survey's National Water-Quality Assessment program.

  3. Intrinsic advantages of packed capillaries over narrow-bore columns in very high-pressure gradient liquid chromatography.

    PubMed

    Gritti, Fabrice; McDonald, Thomas; Gilar, Martin

    2016-06-17

    250μm×100mm fused silica glass capillaries were packed with 1.8μm high-strength silica (HSS) fully porous particles. They were prepared without bulky stainless steel endfittings and metal frits, which both generate significant sample dispersion. The isocratic efficiencies and gradient peak capacities of these prototype capillary columns were measured for small molecules (n-alkanophenones) using a home-made ultra-low dispersive micro-HPLC instrument. Their resolution power was compared to that of standard 2.1mm×100mm very high-pressure liquid chromatography (vHPLC) narrow-bore columns packed with the same particles. The results show that, for the same column efficiency (25000 plates) and gradient steepness (0.04min(-1)), the peak capacity of the 250μm i.d. capillary columns is systematically 15-20% higher than that of the 2.1mm i.d. narrow-bore columns. A validated model of gradient chromatography enabled one to predict accurately the observed peak capacities of the capillary columns for non-linear solvation strength retention behavior and under isothermal conditions. Thermodynamics applied to the eluent quantified the temperature difference for the thermal gradients in both capillary and narrow-bore columns. Experimental data revealed that the gradient peak capacity is more affected by viscous heating than the column efficiency. Unlike across 2.1mm i.d. columns, the changes in eluent composition across the 250μm i.d. columns during the gradient is rapidly relaxed by transverse dispersion. The combination of (1) the absence of viscous heating and (2) the high uniformity of the eluent composition across the diameter of capillary columns explains the intrinsic advantage of capillary over narrow-bore columns in gradient vHPLC. PMID:27185055

  4. Preparative separation and purification of rosmarinic acid from perilla seed meal via combined column chromatography.

    PubMed

    Tang, Weizhuo; Sun, Baoshan; Zhao, Yuqing

    2014-02-01

    In this study, the preparative separation and purification of rosmarinic acid (RA) from perilla seed meal (PSM), which is a by-product of edible oil production, was achieved using combined column chromatography over macroporous and polyamide resins. To optimize the RA enrichment process, the performance and separation characteristics of nine selected macroporous resins with different chemical and physical properties were investigated. SP825 resin was the most effective: the content of RA increased from 0.27% in the original extract to 16.58% in the 50% ethanol fraction (a 61.4-fold increase). During further purification treatment on polyamide resin, 90.23% pure RA could be obtained in the 70% ethanol fraction. RA with a higher purity (>95%) could also be easily obtained using one crystallization operation. The proposed method is simple, easily operated, cost-effective, and environmentally friendly and is suitable for both large-scale RA production and waste management. PMID:24381020

  5. Separation of Be and Al for AMS using single-step column chromatography

    NASA Astrophysics Data System (ADS)

    Binnie, Steven A.; Dunai, Tibor J.; Voronina, Elena; Goral, Tomasz; Heinze, Stefan; Dewald, Alfred

    2015-10-01

    With the aim of simplifying AMS target preparation procedures for TCN measurements we tested a new extraction chromatography approach which couples an anion exchange resin (WBEC) to a chelating resin (Beryllium resin) to separate Be and Al from dissolved quartz samples. Results show that WBEC-Beryllium resin stacks can be used to provide high purity Be and Al separations using a combination of hydrochloric/oxalic and nitric acid elutions. 10Be and 26Al concentrations from quartz samples prepared using more standard procedures are compared with results from replicate samples prepared using the coupled WBEC-Beryllium resin approach and show good agreement. The new column procedure is performed in a single step, reducing sample preparation times relative to more traditional methods of TCN target production.

  6. Column studies for the adsorption of cationic surfactant onto an organic polymer resin and a granular activated carbon.

    PubMed

    Vergili, Ilda; Kaya, Yasemin; Gönder, Zeren Beril; Barlas, Hulusi

    2010-03-01

    Adsorption beds containing granular activated carbon and organic polymer resin are used widely to remove organic pollutants from wastewaters and water streams. Adsorption polymers are becoming alternatives to activated carbon for removal of surfactants by adsorption techniques. This study investigated the adsorption characteristics of cetyl trimethylammonium bromide (CTAB) as a cationic surfactant for selected concentrations below and above critical micelle concentration (CMC). A series of column tests were performed to determine the breakthrough curves by using two different adsorbents: (1) Hydraffin CC 8 x 30 as a commercial granular activated carbon (GAC) and (2) Lewatit VPOC 1064 MD PH as a commercial organic polymer resin. In the experiments, the volumetric flow rate was maintained at 10.5 mL/min (approximately 2 m3/ m2 x h). Loading of adsorbents was continued until breakthrough was 10% of the feed concentration. The breakthrough took place at 488 bed volume (BV) below CMC (C0 = 40 mg/L) and 39 BV above CMC (C0 = 400 mg/ L) onto GAC. The organic polymer resin, however, showed a higher adsorption capacity than GAC (1412 BV below CMC and 287 BV above CMC). From the Logit method, the value of adsorption rate coefficient (K) and adsorption capacity coefficient (N) were obtained. PMID:20369564

  7. pH Transients in hydroxyapatite chromatography columns-experimental evidence and phenomenological modeling.

    PubMed

    Bankston, Theresa E; Dattolo, Laura; Carta, Giorgio

    2010-04-01

    Hydroxyapatite (HAP) columns, widely used for chromatographic separation of proteins and other biomolecules because of their unique selectivity and ability to resolve complex mixtures, exhibit limited stability at acidic conditions requiring careful control of pH. Even with buffered solutions, however, unintended pH transients can occur when the salt concentration varies. For example, the pH temporarily decreases below the feed value when the salt concentration increases and increases above the feed value when the salt concentration is decreased. The intensity and duration of these transients depend on the particular buffer used and the magnitude of the salt concentration step, but in extreme cases the pH can drop by as much as 1.5 pH units creating conditions where the HAP stability is potentially compromised. This work examines the mechanisms leading to pH transients in HAP columns generated by salt steps. The pH excursions are similar to those observed for weak cation exchange columns, but are accompanied by a transient evolution of phosphate which temporarily decreases below the feed value when the salt concentration is increased and increases sharply when the salt concentration is reduced before returning to the feed value. A phenomenological model is developed to describe this behavior by considering the reversible uptake of sodium ions by the P-sites and binding of phosphate ions by the C-sites. The interplay of these two adsorption mechanisms results in complex pH patterns that are consistent with those observed experimentally. In addition to helping understand the underlying mechanisms, the model also provides a useful tool to predict the effects of different buffers and salt concentration and develop corrective measures that can reduce the intensity and duration of the pH transients such as the addition of unretained co-buffers. PMID:20193952

  8. Preparation of porous polymer monolithic column using functionalized graphene oxide as a functional crosslinker for high performance liquid chromatography separation of small molecules.

    PubMed

    Li, Yaping; Qi, Li; Ma, Huimin

    2013-09-21

    A newly developed porous polymer monolith was prepared through copolymerization of 3-(trimethoxysilyl)propylmethacrylate modified graphene oxide with glycidyl methacrylate and ethylene dimethacrylate as a functional crosslinker, which was synthesized through silanization reaction of graphene oxide prepared by Hummers method with 3-(trimethoxysilyl)propylmethacrylate. The monolith was characterized by Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, transmission electron microscopy, scanning electron microscopy, mercury intrusion porosimetry and nitrogen adsorption measurement. The monolith column was applied as the stationary phase of high performance liquid chromatography and its chromatographic performance was evaluated by separation of small molecules in the isocratic reversed-phase mode. The chromatograms of hydrophobic steroids and polar aromatic amines on the prepared monolith displayed the enhanced separation performance over those on the parent monolith. The reproducibility of the column was less than 3.5% in terms of relative standard deviation of retention time. The results demonstrate that copolymerization of functionalized graphene oxide into porous polymer monolith was an effective tool for chromatography separation enhancement of small molecules in an isocratic mode. PMID:23884304

  9. Particle size effects on protein and virus-like particle adsorption on perfusion chromatography media.

    PubMed

    Wu, Yige; Abraham, Dicky; Carta, Giorgio

    2015-01-01

    The resin structure, chromatographic behavior, and adsorption kinetics of proteins and virus-like-particles (VLPs) are studied for POROS HS 20 and POROS HS 50 (23 and 52 μm mean diameter, respectively) to determine the effects of particle size on perfusion chromatography and to determine the predictive ability of available models. Transmission electron microscopy (TEM) and inverse size-exclusion chromatography (iSEC) show similar structures for the two resins, both containing 200-1000 nm pores that transect a network of much smaller pores. For non-binding conditions, trends of the height equivalent to a theoretical plate (HETP) as a function of reduced velocity are consistent with perfusion. The estimated intraparticle flow fractions for these conditions are 0.0018 and 0.00063 for POROS HS 20 and HS 50, respectively. For strong binding conditions, confocal laser scanning microscopy (CLSM) shows asymmetrical intraparticle concentrations profiles and enhanced rates of IgG adsorption on POROS HS 20 at 1000 cm/h. The corresponding effective diffusivity under flow is 2-3 times larger than for non-flow conditions and much larger than observed for POROS HS 50, consistent with available models. For VLPs, however, adsorption is confined to a thin layer near the particle surface for both resins, suggesting that the bound VLPs block the pores. PMID:25512122

  10. Temperature-assisted On-column Solute Focusing: A General Method to Reduce Pre-column Dispersion in Capillary High Performance Liquid Chromatography

    PubMed Central

    Groskreutz, Stephen R.; Weber, Stephen G.

    2014-01-01

    Solvent-based on-column focusing is a powerful and well known approach for reducingthe impact of pre-column dispersion in liquid chromatography. Here we describe an orthogonal temperature-based approach to focusing called temperature-assisted on-column solute focusing (TASF). TASF is founded on the same principles as the more commonly used solvent-based method wherein transient conditions are created thatlead to high solute retention at the column inlet. Combining the low thermal mass of capillary columns and the temperature dependence of solute retentionTASF is used effectivelyto compress injection bands at the head of the column through the transient reduction in column temperature to 5 °C for a defined 7 mm segment of a 6 cm long 150 μm I.D. column. Following the 30 second focusing time, the column temperature is increased rapidly to the separation temperature of 60 °C releasing the focused band of analytes. We developed a model tosimulate TASF separations based on solute retention enthalpies, focusing temperature, focusing time, and column parameters. This model guides the systematic study of the influence of sample injection volume on column performance.All samples have solvent compositions matching the mobile phase. Over the 45 to 1050 nL injection volume range evaluated, TASF reducesthe peak width for all soluteswith k’ greater than or equal to 2.5, relative to controls. Peak widths resulting from injection volumes up to 1.3 times the column fluid volume with TASF are less than 5% larger than peak widths from a 45 nL injection without TASF (0.07 times the column liquid volume). The TASF approach reduced concentration detection limits by a factor of 12.5 relative to a small volume injection for low concentration samples. TASF is orthogonal to the solvent focusing method. Thus, it canbe used where on-column focusing is required, but where implementation of solvent-based focusing is difficult. PMID:24973805

  11. Laboratory column experiments for radionuclide adsorption studies of the Culebra dolomite member of the Rustler Formation

    SciTech Connect

    Lucero, D.A.; Heath, C.E.; Brown, G.O.

    1998-04-01

    Radionuclide transport experiments were carried out using intact cores obtained from the Culebra member of the Rustler Formation inside the Waste Isolation Pilot Plant, Air Intake Shaft. Twenty-seven separate tests are reported here and include experiments with {sup 3}H, {sup 22}Na, {sup 241}Am, {sup 239}Np, {sup 228}Th, {sup 232}U and {sup 241}Pu, and two brine types, AIS and ERDA 6. The {sup 3}H was bound as water and provides a measure of advection, dispersion, and water self-diffusion. The other tracers were injected as dissolved ions at concentrations below solubility limits, except for americium. The objective of the intact rock column flow experiments is to demonstrate and quantify transport retardation coefficients, (R) for the actinides Pu, Am, U, Th and Np, in intact core samples of the Culebra Dolomite. The measured R values are used to estimate partition coefficients, (kd) for the solute species. Those kd values may be compared to values obtained from empirical and mechanistic adsorption batch experiments, to provide predictions of actinide retardation in the Culebra. Three parameters that may influence actinide R values were varied in the experiments; core, brine and flow rate. Testing five separate core samples from four different core borings provided an indication of sample variability. While most testing was performed with Culebra brine, limited tests were carried out with a Salado brine to evaluate the effect of intrusion of those lower waters. Varying flow rate provided an indication of rate dependent solute interactions such as sorption kinetics.

  12. Rapid separation of polysaccharides using a novel spiral coil column by high-speed countercurrent chromatography.

    PubMed

    Li, Weili; Wu, Tao

    2016-04-01

    The separation of polysaccharides is time consuming. We developed and optimized a type-J counter-current chromatography system with a novel tri-rotor spiral coil column for the rapid separation of polysaccharides. The optimal composition of an aqueous PEG1000/K2 HPO4 /KH2 PO4 system was found to be 14:16:14 w/w/w where the lower phase was the mobile phase. Optimal performance was achieved at a column rotational speed, temperature, and flow rate of 1200 rpm, 45°C, and 3.0 mL/min, respectively. The mobile phase was pumped from the inner terminal in a ''head-to-tail'' elution mode. Polysaccharide LCP-1 (10.7 mg) was successfully obtained in high purity in one step from 50.0 mg of a crude polysaccharide extracted from the lychee fruit (Litchi chinensis) within 100 min. LCP-1 possess a number-average molecular weight and weight-average molecular weight of 1.05 × 10(5) and 1.59 × 10(5) kDa, respectively. The monosaccharide composition consists of the molar ratio of glucose, galactose, and arabinose of 1.3:3.5:1. PMID:26857207

  13. The development of mitochondrial membrane affinity chromatography columns for the study of mitochondrial transmembrane proteins.

    PubMed

    Habicht, K-L; Singh, N S; Indig, F E; Wainer, I W; Moaddel, R; Shimmo, R

    2015-09-01

    Mitochondrial membrane fragments from U-87 MG (U87MG) and HEK-293 cells were successfully immobilized onto immobilized artificial membrane (IAM) chromatographic support and surface of activated open tubular (OT) silica capillary, resulting in mitochondrial membrane affinity chromatography (MMAC) columns. Translocator protein (TSPO), located in mitochondrial outer membrane as well as sulfonylurea and mitochondrial permeability transition pore (mPTP) receptors, localized to the inner membrane, were characterized. Frontal displacement experiments with multiple concentrations of dipyridamole (DIPY) and PK-11195 were run on MMAC (U87MG) column, and the binding affinities (Kd) determined were 1.08±0.49 and 0.0086±0.0006μM, respectively, consistent with previously reported values. Furthermore, binding affinities (Ki) for DIPY binding site were determined for TSPO ligands, PK-11195, mesoporphyrin IX, protoporphyrin IX, and rotenone. In addition, the relative ranking of these TSPO ligands based on single displacement studies using DIPY as marker on MMAC (U87MG) was consistent with the obtained Ki values. The immobilization of mitochondrial membrane fragments was also confirmed by confocal microscopy. PMID:26049098

  14. The development of mitochondrial membrane affinity chromatography columns for the study of mitochondrial transmembrane proteins

    PubMed Central

    Habicht, K-L.; Singh, N.S.; Indig, F.E.; Wainer, I.W.; Moaddel, R.; Shimmo, R.

    2015-01-01

    Mitochondrial membrane fragments from U-87 MG (U87MG) and HEK-293 cells were successfully immobilized on to Immobilized Artificial Membrane (IAM) chromatographic support and surface of activated open tubular (OT) silica capillary resulting in mitochondrial membrane affinity chromatography (MMAC) columns. Translocator protein (TSPO), located in mitochondrial outer membrane as well as sulfonylurea and mitochondrial permeability transition pore (mPTP) receptors, localized to the inner membrane, were characterized. Frontal displacement experiments with multiple concentrations of dipyridamole (DIPY) and PK-11195 were run on MMAC-(U87MG) column and the binding affinities (Kd) determined were 1.08 ± 1.49 and 0.0086 ± 0.0006 μM respectively, which was consistent with previously reported values. Further, binding affinities (Ki) for DIPY binding site were determined for TSPO ligands, PK-11195, mesoporphyrin IX, protoporphyrin IX and rotenone. Additionally, the relative ranking of these TSPO ligands based on single displacement studies using DIPY as marker on MMAC-(U87MG) was consistent with the obtained Ki values. The immobilization of mitochondrial membrane fragments was also confirmed by confocal microscopy. PMID:26049098

  15. Separation of proteins by cation-exchange sequential injection chromatography using a polymeric monolithic column.

    PubMed

    Masini, Jorge Cesar

    2016-02-01

    Since sequential injection chromatography (SIC) emerged in 2003, it has been used for separation of small molecules in diverse samples, but separations of high molar mass compounds such as proteins have not yet been described. In the present work a poly(glycidyl methacrylate-co-ethylene dimethacrylate) (GMA-co-EDMA) monolithic column was prepared by free radical polymerization inside a 2.1-mm-i.d. activated fused silica-lined stainless steel tubing and modified with iminodiacetic acid (IDA). The column was prepared from a mixture of 24% GMA, 16% EDMA, 20% cyclohexanol, and 40% 1-dodecanol (all% as w/w) containing 1% of azobisisobutyronitrile (AIBN) (in relation to monomers). Polymerization was done at 60 °C for 24 h. The polymer was modified with 1.0 M IDA (in 2 M Na2CO3, pH 10.5) at 80 °C for 16 h. Separation of myoglobin, ribonuclease A, cytochrome C, and lysozyme was achieved at pH 7.0 (20 mM KH2PO4/K2HPO4) using a salt gradient (NaCl). Myoglobin was not retained, and the other proteins were separated by a gradient of NaCl created inside the holding coil (4 m of 0.8-mm-i.d. PTFE tubing) by sequential aspiration of 750 and 700 μL of 0.2 and 0.1 M NaCl, respectively. As the flow was reversed toward the column (5 μL s(-1)) the interdispersion of these solutions created a reproducible gradient which separated the proteins in 10 min, with the following order of retention: ribonuclease A < cytochrome C < lysozyme. The elution order was consistent with a cation-exchange mechanism as the retention increased with the isoelectric points. PMID:26677024

  16. Understanding and diminishing the extra-column band broadening effects in supercritical fluid chromatography.

    PubMed

    De Pauw, Ruben; Shoykhet Choikhet, Konstantin; Desmet, Gert; Broeckhoven, Ken

    2015-07-17

    Supercritical fluid chromatography, where a low-viscosity mobile phase such as carbon dioxide is used, proves to be an excellent technique for fast and efficient separations, especially when sub-2μm particles are used. However, to achieve high velocities when using these small particles, and in order to stay within the flow rate range of current SFC-instruments, narrow columns (e.g. 2.1mm ID) must be used. Unfortunately, state-of-the-art instrumentation is limiting the full separation power of these narrower columns due to significant extra-column band broadening effects. The present work identifies and quantifies the different contributions to extra-column band broadening in SFC such as the influence of the sample solvent, injection volume, extra-column volumes and detector cell volume/design. When matching the sample solvent to the mobile phase in terms of elution strength and polarity (e.g. using hexane/ethanol/isopropanol 85/10/5vol%) and lowering the injection volume to 0.4μL, the plate count can be increased from 7600 to 21,300 for a low-retaining compound (k'=2.3) on a 2.1mm×150mm column (packed with 1.8μm particles). The application of a water/acetonitrile mixture as sample solvent was also investigated. It was found that when the volumetric ratio of water/acetonitrile was optimized, only a slightly lower plate count was measured compared to the hexane-based solvent when minimizing injection and extra-column volume. This confirms earlier results that water/acetonitrile can be used if water-soluble samples are considered or when a less volatile solvent is preferred. Minimizing the ID of the connection capillaries from 250 to 65μm, however, gives no further improvement in obtained efficiency for early-eluting compounds when a standard system configuration with optimized sample solvent was used. When switching to a state-of-the-art detector design with reduced (dispersion) volume (1.7-0.6μL), an increase in plate count is observed (from 11,000 to 14

  17. Effect of pre- and post-column band broadening on the performance of high-speed chromatography columns under isocratic and gradient conditions.

    PubMed

    Vanderlinden, Kim; Broeckhoven, Ken; Vanderheyden, Yoachim; Desmet, Gert

    2016-04-15

    We report on the results of an experimental and theoretical study of the effect of the extra-column band broadening (ECBB) on the performance of narrow-bore columns filled with the smallest particles that are currently commercially available. Emphasis is on the difference between the effect of ECBB under gradient and isocratic conditions, as well as on the ability to model and predict the ECBB effects using well-established band broadening expressions available from the theory of chromatography. The fine details and assumptions that need to be taken into account when using these expressions are discussed. The experiments showed that, the steeper the gradient, the more pronounced the extra-column band broadening losses become. Whereas the pre-column band broadening can in both isocratic and gradient elution be avoided by playing on the possibilities to focus the analytes on top of the column (e.g. by using the POISe injection method when running isocratic separations), the post-column extra-column band broadening is inescapable in both cases. Inducing extra-column band broadening by changing the inner diameter of the post-column tubing from 65 to 250 μm, we found that all peaks in the chromatogram are strongly affected (around a factor of 1.9 increase in relative peak width) when running steep gradients, while usually only the first eluting peak was affected in the isocratic mode or when running shallow gradients (factor 1.6-1.8 increase in relative peak width for the first eluting analyte). PMID:26987413

  18. Column affinity chromatography for bound/free separation in ligand assays. I. Radioimmunoassay of choriomammotropin (human placental lactogen).

    PubMed

    Cornale, P; Bonazzi, M; Multinu, C; Romelli, P; Vancheri, L; Pennisi, F

    1981-06-01

    A method is described for separating antibody-bound from free fractions in ligand assays by column affinity chromatography, and its application to radioimmunoassay of choriomammotropin. In the method, 70 x 10 mm (i.d.) polypropylene columns containing about 150 mg of immunosorbent (goat anti-rabbit gamma-globulins covalently linked to Sepharose CL-4B) are used. Standards or unknowns, tracer and antiserum, pipetted into bottom-capped columns, are kept separated from the immunosorbent bed by a porous polyethylene disc and allowed to react for 15 min at room temperature. The reaction mixture is then allowed to pass through the columns by removing the bottom caps. Free antigen is eluted by washing the column, and discarded; antibody-bound fractions remain bound to the immunosorbent. The radioactivity in the columns is counted. The major advantages of the present technique, arising from the liquid-phase reaction combined with the solid-phase separation by column affinity chromatography, are the very low nonspecific binding (less than 1%), good sensitivity (0.02 mg/L), good precision (CV 3.4%), and simple and fast (30-min) assay. For 50 clinical samples so assayed (gamma) and compared with a polyethylene glycol precipitation technique (x), the regression equation was: y - 0.14 + 0.98x (r = 0.994). The assay method was clinical validated by 3493 determinations. PMID:7237770

  19. Characterization of column packing materials in high-performance liquid chromatography by charge-detection quadrupole ion trap mass spectrometry.

    PubMed

    Xiong, Caiqiao; Zhou, Xiaoyu; Chen, Rui; Zhang, Yiming; Peng, Wen-Ping; Nie, Zongxiu; Chang, Huan-Cheng; Liu, Huwei; Chen, Yi

    2011-07-01

    This article reports an application of charge-detection quadrupole ion trap mass spectrometry (CD-ITMS) to characterize the column packing materials in high-performance liquid chromatography (HPLC). Both the mean mass and the mass distribution of the packing materials are obtained and used to calculate the specific surface area of unbonded silica, the carbon load of the bonded silica, and their particle size distributions. The obtained specific surface areas and carbon loads are consistent with those measured independently by nitrogen sorption and elemental analysis respectively, whereas the derived size distributions show better resolution than that measured by a laser particle size analyzer. Furthermore, we evaluate the uniformity of particle size, which is the key parameter for column efficiency of the liquid chromatography by analyzing the mass distribution of the packing materials at the top and bottom of the column. A broader mass distribution, which yields decreased column efficiency, is observed for the column top because of the excessive use of the column. Our results suggest that CD-ITMS can serve as an alternative means for the characterization of the packing materials in HPLC and is potentially useful for column quality control. PMID:21612293

  20. A protocol for the measurement of all the parameters of the mass transfer kinetics in columns used in liquid chromatography

    SciTech Connect

    Gritti, Fabrice; Guiochon, Georges A

    2010-01-01

    Band broadening in chromatography results from the combination of the dispersive effects that are associated with the different steps involved in the migration of compound bands along the column. These steps include longitudinal diffusion, trans-particle mass transfer, external film mass transfer, overall eddy diffusion, including trans-column, short-range inter-channel, trans-channel eddy diffusion, and the possible, additional mass transfer contributions arising from heat friction and the thermal heterogeneity of the column. We describe a series of experiments that provide the data needed to determine the coefficients of the contributions to band broadening of each one of these individual mass transfer steps. This specifically designed protocol can provide key information regarding the kinetic performance of columns used in liquid chromatography and explain why different columns behave so differently. The limitations, accuracy and precision of these methods are discussed. Further avenues of research that could improve the characterization of the mass transfer mechanisms in chromatographic columns, possibly contributing to the development of better columns, are suggested.

  1. Using Artificial Soil and Dry-Column Flash Chromatography to Simulate Organic Substance Leaching Process: A Colorful Environmental Chemistry Experiment

    ERIC Educational Resources Information Center

    de Avellar, Isa G. J.; Cotta, Tais A. P. G.; Neder, Amarilis de V. Finageiv

    2012-01-01

    Soil is an important and complex environmental compartment and soil contamination contributes to the pollution of aquifers and other water basins. A simple and low-cost experiment is described in which the mobility of three organic compounds in an artificial soil is examined using dry-column flash chromatography. The compounds were applied on top…

  2. A filtration and column-adsorption system for onsite concentration and fractionation of organic substances from large volumes of water

    USGS Publications Warehouse

    Leenheer, J.A.; Noyes, T.I.

    1984-01-01

    A portable filtration and column-adsorption system which can concentrate suspended sediment and dissolved-aqueous organic substances onsite was developed. Organic solutes also are fractionated into hydrophobic- and hydrophilic-acid, base, and neutral fractions. Subsequent isolation of organic solutes from fraction concentrates and extraction of organic constituents in suspended sediment entrained on filter tubes is performed by a variety of procedures in the laboratory. Three surface-water samples and one ground-water sample ranging in volume from 300 to 1,100 liters were processed through the filtration and column-adsorption system, yielding from about 0.8 to 3.0 grams of recovered organic carbon per sample.

  3. Adsorption of lead at variable pH onto a natural porous medium: Modeling of batch and column experiments

    SciTech Connect

    Papini, M.P.; Kahie, Y.D.; Troia, B.; Majone, M.

    1999-12-15

    The surface complexation approach has been applied to describe the adsorption of lead and proton onto a heterogeneous natural porous medium at constant ionic strength. Acid-base titration experiments were used to determine the minimum number of sites needed to describe the surface heterogeneity. Lead adsorption tests at several pH and total lead concentration were used to complete the model structure, whose adjustable parameters (site concentration and apparent formation constants) were determined by nonlinear multivariate regression of titration and adsorption data. The final model represents the acid-base properties of the surface by the presence of two amphoteric sites, SOH and TOH, and a monoprotic one, MOH; whereas lead adsorption is considered only onto SOH and MOH sites. The model allows a good representation of the experimental behavior in the whole experimental range. Theoretical surface speciation shows that lead adsorption occurs mostly onto site MOH at low pH level and on both SOH and MOH sites at higher values. The model was independently validated by simulating Pb and pH breakthrough experiments performed in small chromatographic columns. Experimental breakthroughs are well predicted by an advection-dispersion transport model coupled with the chemical equilibrium routine (IMPACT), without any parameter adjustment. A large spreading of Pb and pH breakthroughs was calculated and experimentally observed, even in the absence of any kinetic effect. That spreading is explained in terms of the concomitant presence of competitive adsorption and surface heterogeneity.

  4. Optimal performance of single-column chromatography and simulated moving bed processes for the separation of optical isomers

    NASA Astrophysics Data System (ADS)

    Medi, Bijan; Kazi, Monzure-Khoda; Amanullah, Mohammad

    2013-06-01

    Chromatography has been established as the method of choice for the separation and purification of optically pure drugs which has a market size of about 250 billion USD. Single column chromatography (SCC) is commonly used in the development and testing phase of drug development while multi-column Simulated Moving Bed (SMB) chromatography is more suitable for large scale production due to its continuous nature. In this study, optimal performance of SCC and SMB processes for the separation of optical isomers under linear and overloaded separation conditions has been investigated. The performance indicators, namely productivity and desorbent requirement have been compared under geometric similarity for the separation of a mixture of guaifenesin, and Tröger's base enantiomers. SCC process has been analyzed under equilibrium assumption i.e., assuming infinite column efficiency, and zero dispersion, and its optimal performance parameters are compared with the optimal prediction of an SMB process by triangle theory. Simulation results obtained using actual experimental data indicate that SCC may compete with SMB in terms of productivity depending on the molecules to be separated. Besides, insights into the process performances in terms of degree of freedom and relationship between the optimal operating point and solubility limit of the optical isomers have been ascertained. This investigation enables appropriate selection of single or multi-column chromatographic processes based on column packing properties and isotherm parameters.

  5. Trend analysis of performance parameters of pre-packed columns for protein chromatography over a time span of ten years.

    PubMed

    Scharl, Theresa; Jungreuthmayer, Christian; Dürauer, Astrid; Schweiger, Susanne; Schröder, Tim; Jungbauer, Alois

    2016-09-23

    Pre-packed small scale chromatography columns are increasingly used for process development, for determination of design space in bioprocess development, and for post-licence process verifications. The packing quality of 30,000 pre-packed columns delivered to customers over a period 10 years has been analyzed by advanced statistical tools. First, the data were extracted and checked for inconsistencies, and then were tabulated and made ready for statistical processing using the programming language Perl (https://www.perl.org/) and the statistical computing environment R (https://www.r-project.org/). Reduced HETP and asymmetry were plotted over time to obtain a trend of packing quality over 10 years. The obtained data were used as a visualized coefficient of variation analysis (VCVA), a process that has often been applied in other industries such as semiconductor manufacturing. A typical fluctuation of reduced HETP was seen. A Tsunami effect in manufacturing, the effect of propagation of manufacturing deviations leading to out-of-specification products, was not observed with these pre-packed columns. Principal component analysis (PCA) showed that all packing materials cluster. Our data analysis showed that the current commercially available chromatography media used for biopharmaceutical manufacturing can be reproducibly and uniformly packed in polymer-based chromatography columns, which are designed for ready-to-use purposes. Although the number of packed columns has quadrupled over one decade the packing quality has remained stable. PMID:27575920

  6. Aqueous phase adsorption of cephalexin by walnut shell-based activated carbon: A fixed-bed column study

    NASA Astrophysics Data System (ADS)

    Nazari, Ghadir; Abolghasemi, Hossein; Esmaieli, Mohamad; Sadeghi Pouya, Ehsan

    2016-07-01

    The walnut shell was used as a low cost adsorbent to produce activated carbon (AC) for the removal of cephalexin (CFX) from aqueous solution. A fixed-bed column adsorption was carried out using the walnut shell AC. The effect of various parameters like bed height (1.5, 2 and 2.5 cm), flow rate (4.5, 6 and 7.5 mL/min) and initial CFX concentration (50, 100 and 150 mg/L) on the breakthrough characteristics of the adsorption system was investigated at optimum pH 6.5. The highest bed capacity of 211.78 mg/g was obtained using 100 mg/L inlet drug concentration, 2 cm bed height and 4.5 mL/min flow rate. Three kinetic models, namely Adam's-Bohart, Thomas and Yoon-Nelson were applied for analysis of experimental data. The Thomas and Yoon-Nelson models were appropriate for walnut shell AC column design under various conditions. The experimental adsorption capacity values were fitted to the Bangham and intra-particle diffusion models in order to propose adsorption mechanisms. The effect of temperature on the degradation of CFX was also studied.

  7. Analysis of drugs in plasma samples from schizophrenic patients by column-switching liquid chromatography-tandem mass spectrometry with organic-inorganic hybrid cyanopropyl monolithic column.

    PubMed

    Domingues, Diego Soares; Souza, Israel Donizeti de; Queiroz, Maria Eugênia Costa

    2015-07-01

    This study reports on the development of a rapid, selective, and sensitive column-switching liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to analyze sixteen drugs (antidepressants, anticonvulsants, anxiolytics, and antipsychotics) in plasma samples from schizophrenic patients. The developed organic-inorganic hybrid monolithic column with cyanopropyl groups was used for the first dimension of the column-switching arrangement. This arrangement enabled online pre-concentration of the drugs (monolithic column) and their subsequent analytical separation on an XSelect SCH C18 column. The drugs were detected on a triple quadrupole tandem mass spectrometer (multiple reactions monitoring mode) with an electrospray ionization source in the positive ion mode. The developed method afforded adequate linearity for the sixteen target drugs; the coefficients of determination (R(2)) lay above 0.9932, the interassay precision had coefficients of variation lower than 6.5%, and the relative standard error values of the accuracy ranged from -14.0 to 11.8%. The lower limits of quantification in plasma samples ranged from 63 to 1250pgmL(-1). The developed method successfully analyzed the target drugs in plasma samples from schizophrenic patients for therapeutic drug monitoring (TDM). PMID:25984963

  8. Adsorption of hexavalent chromium from synthetic and electroplating effluent on chemically modified Swietenia mahagoni shell in a packed bed column.

    PubMed

    Rangabhashiyam, S; Nandagopal, M S Giri; Nakkeeran, E; Selvaraju, N

    2016-07-01

    Packed bed column studies were carried out to evaluate the performance of chemically modified adsorbents for the sequestration of hexavalent chromium from synthetic and electroplating industrial effluent. The effects of parameters such as bed height (3-9 cm), inlet flow rate (5-15 mL/min), and influent Cr(VI) concentration (50-200 mg/L) on the percentage removal of Cr(VI) and the adsorption capacity of the adsorbents in a packed bed column were investigated. The breakthrough time increased with increasing bed height and decreased with the increase of inlet flow rate and influent Cr(VI) concentration. The adsorption column models such as Thomas, Adams-Bohart, Yoon-Nelson, and bed depth service time (BDST) were successfully correlated with the experimental data. The Yoon-Nelson and BDST model showed good agreement with the experimental data for all the studied parameter conditions. Results of the present study indicated that the chemically modified Swietenia mahagoni shell can be used as an adsorbent for the removal of Cr(VI) from industrial wastewater in a packed bed column. PMID:27312254

  9. A reduced order model for the study of asymmetries in linear gas chromatography for homogeneous tubular columns.

    SciTech Connect

    Whiting, Joshua J.; Romero, Louis Anthony; Parks, Michael L.

    2005-08-01

    In gas chromatography, a chemical sample separates into its constituent components as it travels along a long thin column. As the component chemicals exit the column they are detected and identified, allowing the chemical makeup of the sample to be determined. For correct identification of the component chemicals, the distribution of the concentration of each chemical along the length of the column must be nearly symmetric. The prediction and control of asymmetries in gas chromatography has been an active research area since the advent of the technique. In this paper, we develop from first principles a general model for isothermal linear chromatography. We use this model to develop closed-form expressions for terms related to the first, second, and third moments of the distribution of the concentration, which determines the velocity, diffusion rate, and asymmetry of the distribution. We show that for all practical experimental situations, only fronting peaks are predicted by this model, suggesting that a nonlinear chromatography model is required to predict tailing peaks. For situations where asymmetries arise, we analyze the rate at which the concentration distribution returns to a normal distribution. Numerical examples are also provided.

  10. Fabrication of electrolytic cell for online post-column electrochemical derivatization in ion chromatography.

    PubMed

    Wu, Shuchao; Xu, Wei; Yang, Bingcheng; Ye, Mingli; Zhang, Peimin; Shen-Tu, Chao; Zhu, Yan

    2012-07-20

    An electrolytic cell (EC), composed of two ruthenium-plated titanium electrodes separated by cation-exchange membranes, was fabricated and evaluated for online postcolumn derivatization in ion chromatography (IC). Folic acid (FA) and methotrexate (MTX) were preliminarily used as prototype analytes to test the performance of EC. After separation by an anion exchange column, FA and MTX, which emit very weak fluorescence when excited, were electrochemically oxidized online in the anode chamber of the EC. The compounds with strong fluorescence, which are oxidation products, were detected by the fluorescence detector. The phosphate buffer solution (100 mM KH(2)PO(4)) served as an optimal eluent for anion exchange chromatographic separation and a suitable supporting electrolyte for electro-oxidation, leading to ideal compatibility between IC separation and the postcolumn electrochemical derivatization. For the presently proposed method, the linear ranges were from 0.01 mg L(-1) to 5 mg L(-1) for both FA and MTX. The detection limits of FA and MTX were 1.8 and 2.1 μg L(-1), and the relative standard deviations (RSD, n=7) were 2.9% and 3.6%, respectively. The method was applied for the simultaneous determination of FA and MTX in the plasma of patients being treated for rheumatoid arthritis. The determination of MTX in the urine of the patients of diffuse large B cell lymphoma was also demonstrated. PMID:22713918

  11. High purity isolation and quantification of semiconducting carbon nanotubes via column chromatography.

    PubMed

    Tulevski, George S; Franklin, Aaron D; Afzali, Ali

    2013-04-23

    The isolation of semiconducting carbon nanotubes (CNTs) to ultrahigh (ppb) purity is a prerequisite for their integration into high-performance electronic devices. Here, a method employing column chromatography is used to isolate semiconducting nanotubes to 99.9% purity. The study finds that by modifying the solution preparation step, both the metallic and semiconducting fraction are resolved and elute using a single surfactant system, allowing for multiple iterations. Iterative processing enables a far more rapid path to achieving the level of purities needed for high performance computing. After a single iteration, the metallic peak in the absorption spectra is completely attenuated. Although absorption spectroscopy is typically used to characterize CNT purity, it is found to be insufficient in quantifying solutions of high purity (>98 to 99%) due to low signal-to-noise in the metallic region of ultrahigh purity solutions. Therefore, a high throughput electrical testing method was developed to quantify the degree of separation by characterizing ∼4000 field-effect transistors fabricated from the separated nanotubes after multiple iterations of the process. The separation and characterization methods described here provide a path to produce the ultrahigh purity semiconducting CNT solutions needed for high performance electronics. PMID:23484490

  12. The fabrication of monolithic capillary column based on poly (bisphenol A epoxy vinyl ester resin-co-ethylene glycol dimethacrylate) and its applications for the separation of small molecules in high performance liquid chromatography.

    PubMed

    Niu, Wenjing; Wang, Lijuan; Bai, Ligai; Yang, Gengliang

    2013-07-01

    A new polymeric monolith was synthesized in fused-silica capillary by in situ polymerization technique. In the polymerization, bisphenol A epoxy vinyl ester resin (VER) was used as the functional monomer, ethylene glycol dimethacrylate (EDMA) as the crosslinking monomer, 1,4-butanediol, 1-propanol and water as the co-porogens, and azobisisobutyronitrile (AIBN) as the initiator. The conditions of polymerization have been optimized. Morphology of the prepared poly (VER-co-EDMA) monolith was investigated by the scanning electron microscopy (SEM); pore properties were assayed by mercury porosimetry and nitrogen adsorption. The optimized poly (VER-co-EDMA) monolith showed a uniform structure, good permeability and mechanical stability. Then, the column was used as the stationary phase of high performance liquid chromatography (HPLC) to separate the mixture of benzene derivatives. The best column efficiency achieved for phenol was 235790 theoretical plates per meter. Baseline separations of benzene derivatives and halogenated benzene compounds under optimized isocratic mode conditions were achieved with high column efficiency. The column showed good reproducibility: the relative standard deviation (RSD) values based on the retention times (n=3) for run-to-run, column-to-column and batch-to-batch were less than 0.98, 1.68, 5.48%, respectively. Compared with poly (BMA-co-EDMA) monolithic column, the proposed monolith exhibited more efficiency in the separation of small molecules. PMID:23726080

  13. Studies on the Performance of Different Coiled Column Configurations for Compact Type-I Counter-current Chromatography

    PubMed Central

    Yang, Yi; Gu, Dongyu; Aisa, Haji Akber; Ito, Yoichiro

    2011-01-01

    Three types of novel coiled column configurations, i.e., a triangular coiled column and elliptical coiled columns I and II, were designed for type-I countercurrent chromatography and their performances were evaluated with two solvent systems each with suitable test samples. Three DNP-amino acids (DNP-DL-glu, DNP-β-ala and DNP-L-ala) were separated with a moderately hydrophobic two-phase solvent system composed of hexane-ethyl acetate-metanol-0.1M hydrochloric acid (1:1:1:1, v/v), while two dipeptides (tryptophyl tyrosine and valyl-tyrosine) were separated with a polar solvent system composed of 1-butanol-acetic acid-water (4.75:0.25:5, v/v). The overall results indicated that the performance of compact type-I counter-current chromatography was improved by elliptical coiled column II which was mounted with its maximum coil diameter perpendicular to the surface of the column holder. Hydrodynamic effects involved in these separations were discussed. PMID:21491597

  14. Adsorption of Methyl Tertiary Butyl Ether on Granular Zeolites: Batch and Column Studies

    PubMed Central

    Abu-Lail, Laila; Bergendahl, John A.; Thompson, Robert W.

    2010-01-01

    Methyl tertiary butyl ether (MTBE) has been shown to be readily removed from water with powdered zeolites, but the passage of water through fixed beds of very small powdered zeolites produces high friction losses not encountered in flow through larger sized granular materials. In this study, equilibrium and kinetic adsorption of MTBE onto granular zeolites, a coconut shell granular activated carbon (CS-1240), and a commercial carbon adsorbent (CCA) sample was evaluated. In addition, the effect of natural organic matter (NOM) on MTBE adsorption was evaluated. Batch adsorption experiments determined that ZSM-5 was the most effective granular zeolite for MTBE adsorption. Further equilibrium and kinetic experiments verified that granular ZSM-5 is superior to CS-1240 and CCA in removing MTBE from water. No competitive-adsorption effects between NOM and MTBE were observed for adsorption to granular ZSM-5 or CS-1240, however there was competition between NOM and MTBE for adsorption onto the CCA granules. Fixed-bed adsorption experiments for longer run times were performed using granular ZSM-5. The bed depth service time model (BDST) was used to analyze the breakthrough data. PMID:20153106

  15. Synthetic lepidocrocite for phosphorous removal from reclaimed water: optimization using convex optimization method and successive adsorption in fixed bed column.

    PubMed

    Wang, Qin; Zhang, Bo; Wang, Muhua; Wu, Jiang; Li, Yuyou; Gao, Yingxin; Li, Weicheng; Jin, Yong

    2016-11-01

    The batch and column experimental studies on the adsorption of phosphate onto synthetic lepidocrocite from reclaimed water are presented. A second-order polynomial model in the batch study is successfully applied to describe phosphate immobilization performance using the response surface methodology. The model proposed is further linked with the convex optimization method to determine the optimal variables for maximum phosphate uptake since convex method is a global optimization method. Consequently, under optimal parameters determined as pH of 3.88, an initial P concentration of 0.66 mg/L, and a dosage of 0.15 g, the corresponding phosphate removal efficiency can reach up to 97.4%. Adsorption behavior is further revealed by X-ray photoelectron spectroscopy observation and FTIR spectra. A comparative column study indicates that co-existing competing anions in artificial reclaimed water do not significantly interfere with P adsorption under the neutral condition. The experimental results highlight that synthetic lepidocrocite is an excellent absorbent for sustainable P removal from reclaimed water. PMID:27121116

  16. Recombinant protein purification using gradient-assisted simulated moving bed hydrophobic interaction chromatography. Part I: selection of chromatographic system and estimation of adsorption isotherms.

    PubMed

    Palani, Sivakumar; Gueorguieva, Ludmila; Rinas, Ursula; Seidel-Morgenstern, Andreas; Jayaraman, Guhan

    2011-09-16

    The design of gradient simulated moving bed (SMB) chromatographic processes requires an appropriate selection of the chromatographic system followed by the determination of adsorption isotherm parameters in the relevant range of mobile phase conditions. The determination of these parameters can be quite difficult for recombinant target proteins present in complex protein mixtures. The first part of this work includes the estimation of adsorption isotherm parameters for streptokinase and a lumped impurity fraction present in an Escherichia coli cell lysate for a hydrophobic interaction chromatography (HIC) matrix. Perturbation experiments were carried out using a Butyl Sepharose matrix with purified recombinant protein on buffer equilibrated columns as well as with crude cell lysate saturated columns. The Henry constants estimated for streptokinase were found to exhibit in a wide range a linear dependence on the salt concentration in the mobile phase. These parameters were applied in subsequent investigations to design a simulated moving bed (SMB) process capable to purify in a continuous manner recombinant streptokinase from the E. coli cell lysate. PMID:21816402

  17. Porous molecularly imprinted monolithic capillary column for on-line extraction coupled to high-performance liquid chromatography for trace analysis of antimicrobials in food samples.

    PubMed

    Zhang, Qianchun; Xiao, Xiaohua; Li, Gongke

    2014-06-01

    A novel porous molecularly imprinted monolithic capillary column (MIMCC) based on ternary porogen was synthesized by in situ technique with sulfaquinoxaline as the template molecule. The characteristics of the MIMCC were investigated by scanning electron microscopy, infrared spectrum, thermogravimetric analysis and solvent resistance test. The saturated adsorption amount of sulfaquinoxaline on MIMCC was 2.7 times over that on the non-imprinted monolithic capillary column (NIMCC). The MIMCC also exhibited good enrichment ability to its analogs and the enrichment factors were 46-211 for five antimicrobials. High permeability and imprinting factors as well as good stability, reproducibility and long lifetime were obtained. An on-line method based on MIMCC solid-phase microextraction coupled with high-performance liquid chromatography was developed for the determination of trace antimicrobials in complex samples. The good linearity for sulfametoxydiazine, sulamethoxazole and sulfaquinoxaline was 0.05-10 µg/L, the limits of detection (LODs) were 10.0-14.0 ng/L. The linear range for mequindox and quinocetone were 0.10-10.0 µg/L, the LODs were 20.0-27.0 ng/L respectively. The recoveries were 71.0-108.2% with relative standard deviation of 1.6-8.5%, correspondingly. The results showed that MIMCC could effectively enrich antimicrobials from complex matrices. The on-line method based on MIMCC and HPLC was selective, sensitive and convenient for trace determination of antimicrobials in complex samples. PMID:24725865

  18. Adsorption of zwitterionic surfactant on limestone measured with high-performance liquid chromatography: micelle-vesicle influence.

    PubMed

    Nieto-Alvarez, David Aaron; Zamudio-Rivera, Luis S; Luna-Rojero, Erick E; Rodríguez-Otamendi, Dinora I; Marín-León, Adlaí; Hernández-Altamirano, Raúl; Mena-Cervantes, Violeta Y; Chávez-Miyauchi, Tomás Eduardo

    2014-10-21

    Herein is presented a new methodology to determine the static adsorption of a zwitterionic surfactant on limestone in three different aqueous media [high-performance liquid chromatography (HPLC) water, seawater, and connate water] with the use of HPLC at room temperature and 70 °C. The results showed that, in both HPLC water and seawater, the surfactant adsorption followed a monolayer Langmuir tendency. In contrast, for connate water, the surfactant presented a new adsorption profile, characterized by two regions: (i) At surfactant concentrations below 1500 mg L(-1), an increase of adsorption is observed as the amount of divalent cations increases in the aqueous media. (ii) At surfactant concentrations above 1500 mg L(-1), the adsorption decreases because the equilibrium, monomer ⇆ micelle ⇆ vesicle, is shifted to the formation of vesicles, giving as a result a decrease in the concentration of monomers, thus reducing the interaction between the surfactant and the rock, and therefore, lower adsorption values were obtained. The behavior of the surfactant adsorption under different concentrations of divalent cations was well-described by the use of a new modified Langmuir model: (dΓ/dt)ads = k(ads)c(Γ∞ - Γ) - k(cmc)(c - c(cmc))(n)ΓH(c - c(cmc)). It was also observed that, as the temperature increases, the adsorption is reduced because of the exothermic nature of the adsorption processes. PMID:25254947

  19. Study on the Alkaloids in Tibetan Medicine Aconitum pendulum Busch by HPLC-MSn Combined with Column Chromatography.

    PubMed

    Wang, Beibei; Dong, Jie; Ji, Jiaojiao; Yuan, Jiang; Wang, Jiali; Wu, Jiarui; Tan, Peng; Liu, Yonggang

    2016-01-01

    A rapid, convenient and effective identification method of alkaloids was established and an attempt on isolating and analyzing the alkaloids in Aconitum pendulum Busch was conducted successfully. In this article, four high-content components including deoxyaconitine, benzoylaconine, aconine and neoline were isolated by using column chromatography. HPLC-MS(n)was employed to deduce the regulations of fragmentation of diterpenoid alkaloids which displayed a characteristic behavior of loss of CO(28u), CH3COOH(60u), CH3OH(32u), H2O(18u) and C6H5COOH(122u). Then, according to fragmentation regulation of mass spectrometry, 42 alkaloids were found inA. pendulum Among them, 38 compounds were identified and 29 alkaloids were reported for the first time for this herb. Therefore, this means that HPLC-MS(n)combined with column chromatography could work as an effective and reliable tool for rapid identification of the chemical components of herbal medicine. PMID:26896350

  20. Sulfonation of crosslinked styrene/divinyl benzene copolymer beads formed from porous foam and ion adsorption of copper by them: column adsorption modeling.

    PubMed

    Barlik, Necla; Keskinler, Bülent

    2014-01-01

    The porous foam is made by the polymerisation of a high internal phase emulsion and it is a highly porous, low density, open cellular material. Surface properties of the foam were chemically modified via a sulfonation process. Sulfonation added ‒SO3(‒)H(+) groups to the polymer matrix. The ion adsorption behavior of copper ions on sulfonated polymer beads, depending on inlet concentration (10-60 mg/L), pH of inlet solution (2.00-5.20) and flow velocity (1.7-11.4 m/h) was studied. It was shown that the amount of copper adsorbed was not affected with increasing concentration of feed solutions and flow velocity. Also the process was highly pH dependent. The maximum removal was 117.96 mg Cu/g dry adsorbent at flow velocity 11.4 m/h. Column experimental tests were conducted to provide data for theoretical modeling and to verify the system performance of the process. A theoretical column model adopted in this work was found to describe well the ion adsorption breakthrough characteristics. PMID:24473296

  1. Analysis of phytochelatins in plant matrices by pre-column derivatization, high-performance liquid chromatography and fluorescence-detection.

    PubMed

    Döring, S; Korhammer, S; Oetken, M; Markert, B

    2000-02-01

    A sensitive method for the determination of phytochelatins in plant matrices by pre-column derivatization with monobromobimane (mBrB) and high-performance liquid chromatography (HPLC) on reversed phases and fluorescence-detection has been developed and applied to cucumber sprouts (Cucumis sativus) treated with cadmium and to the water moss Fontinalis antipyretica (Cd in environmentally-relevant concentrations). Whereas phytochelatins were found in the Cd-treated sprouts, no phytochelatins were detected in Fontinalis anitipyretica. PMID:11225681

  2. Preparative purification and desalting of bases and nucleosides labeled with tritium by column chromatography on sephadex G-10

    SciTech Connect

    Yalovleva, L.A.; Kaminskii, Y.L.; Kozyreva, O.I.; Nagorskii, A.I.; Patokina, N.A.; Sosnova, L.P.

    1986-03-01

    The authors demonstrate the application of column chromatography on Sephadex G-10 and elution with water for the isolation of tritium labeled components of nucleic acids from reaction mixtures after catalytic dehalogenation or enzymic desoxyribosylation and simultaneous removal from inorganic salts. Distribution constants of 16 bases and nucleosides on elution with water were determined. Comparison of the sorbents with Sephadex G-20 disclosed the undoubted advantages of the latter in processes of desalting and separation of mixtures of bases and nucleosides.

  3. Effects of reactor decontamination complexing agents on soil adsorption-column studies

    SciTech Connect

    Serne, R. Jeffrey; Lindenmeier, Clark W.; Cantrell, Kirk J.; Owen, Antionette T.

    1999-12-01

    The effects of picolinate, an organic ligand used to decontaminate nuclear reactor cooling systems, in leachates generated from shallow-land burial (SLB) of low-level nuclear wastes (LLW) on soil adsorption was determined. Using batch adsorption tests and varying the concentration of picolinate, the adsorption tendencies of two metals [Ni(II) and U(VI)] and the ligand were measured as a function of solution pH. We found that when total metal concentrations were fixed at 10^-5 M, picolinate at ligand-to-metal [L:M] ratios $10 did significantly reduce adsorption of Ni but even at a L:M ratio of 100 there was no effect on U(VI) adsorption. These results are compared with data on other metals in the presence of picolinate and for metal adsorption in the presence of EDTA. We conclude that picolinic acid is less of a threat than EDTA in waste leachates to reduce metal adsorption (increase mobility) and that picolinate concentrations must reach or exceed 10^-4 M for the most impacted metals (i.e., those that form the very strongest complexes with picolinate). There are no leachate data on these decontamination agents for the common burial technique (disposal of de-watered resins in high integrity containers) that can be used to evaluate potential hazards of these organo-radionuclide complexes.

  4. Determination of chlorophylls in Taraxacum formosanum by high-performance liquid chromatography-diode array detection-mass spectrometry and preparation by column chromatography.

    PubMed

    Loh, Chin Hoe; Inbaraj, Baskaran Stephen; Liu, Man Hai; Chen, Bing Huei

    2012-06-20

    Taraxacum formosanum, a well-known Chinese herb shown to be protective against hepatic cancer as well as liver and lung damage, may be attributed to the presence of abundant carotenoids and chlorophylls. However, the variety and content of chlorophylls remain uncertain. The objectives of this study were to develop an high-performance liquid chromatography-diode array detection-mass spectrometry method for determination of chlorophylls in T. formosanum and preparation by column chromatography. An HyPURITY C18 column and a gradient mobile phase of water (A), methanol (B), acetonitrile (C), and acetone (D) could resolve 10 chlorophylls and an internal standard Fast Green FCF within 30 min with a flow rate at 1 mL/min and detection at 660 nm. Both chlorophylls a and a' were present in the largest amount (1389.6 μg/g), followed by chlorophylls b and b' (561.2 μg/g), pheophytins a and a' (31.7 μg/g), hydroxychlorophyll b (26.5 μg/g), hydroxychlorophylls a and a' (9.8 μg/g), and chlorophyllides a and a' (0.35 μg/g). A glass column containing 52 g of magnesium oxide-diatomaceous earth (1:3, w/w) could elute chlorophylls with 800 mL of acetone containing 50% ethanol at a flow rate of 10 mL/min. Some new chlorophyll derivatives including chlorophyllide b, pyropheophorbide b, hydroxypheophytin a, and hydroxypheophytin a' were generated during column chromatography but accompanied by a 63% loss in total chlorophylls. Thus, the possibility of chlorophyll fraction prepared from T. formosanum as a raw material for future production of functional food needs further investigation. PMID:22656126

  5. Isolation of organic acids from large volumes of water by adsorption chromatography

    USGS Publications Warehouse

    Aiken, George R.

    1984-01-01

    The concentrations of dissolved organic carbon from most natural waters ranges from 1 to 20 milligrams carbon per liter, of which approximately 75 percent are organic acids. These acids can be chromatographically fractionated into hydrophobic organic acids, such as humic substances, and hydrophilic organic acids. To effectively study any of these organic acids, they must be isolated from other organic and inorganic species, and concentrated. Usually, large volumes of water must be processed to obtain sufficient quantities of material, and adsorption chromatography on synthetic, macroporous resins has proven to be a particularly effective method for this purpose. The use of the nonionic Amberlite XAD-8 and Amberlite XAD-4 resins and the anion exchange resin Duolite A-7 for isolating and concentrating organic acids from water is presented.

  6. Simple automated generation of gradient elution conditions in sequential injection chromatography using monolithic column.

    PubMed

    Koblová, Petra; Sklenářová, Hana; Chocholouš, Petr; Polášek, Miroslav; Solich, Petr

    2011-06-15

    The paper deals with the concept of simple automated creation of gradient profile of the mobile phase for gradient-elution sequential injection chromatography (GE-SIC). The feasibility and merits of this concept are demonstrated on the separation and simultaneous assay of indomethacin as active principle and of its two degradation products (5-methoxy-2-methylindoleacetic acid and 4-chloro-benzoic acid) in a topical pharmaceutical formulation. The GE-SIC separation was performed with a FIAlab(®) 3000 SIC set-up (USA) equipped with an Onyx™ Monolithic C18 (25 mm × 4.6mm, Phenomenex(®)) column, a six-port selection valve, a 5-mL syringe pump and a fiber-optics UV CCD detector. Ketoprofen was used as an internal standard (IS). The gradient elution was achieved by automated reproducible mixing of acetonitrile and aqueous 0.2% phosphoric acid in the holding coil of the SIC system. Different profiles of the gradient elution were tested. The optimal gradient using two mobile phases 30:70 and 50:50 of acetonitrile/0.2% phosphoric acid (v/v) was achieved under the optimum flow rate 1.2 mL min(-1). The chromatographic resolution R between the peaks of all solutes (including the IS) was >2.00. The repeatability of retention times was characterized by the RSD values 0.18-0.30% (n=6). Net separation time was 3.5 min and the mobile phase consumption was 4.5 mL for a single GE-SIC assay. The figures of merit of the novel GE-SIC method compared well with those of conventional HPLC. PMID:21641437

  7. Research on the separation properties of empty-column gas chromatography (EC-GC) and conditions for simulated distillation (SIMDIS).

    PubMed

    Boczkaj, Grzegorz; Kamiński, Marian

    2013-10-01

    Previous studies have revealed it is possible to separate a high-boiling mixture by gas chromatography in empty fused-silica capillary tubing rather than in columns coated with stationary phase. Chromatographic separation occurs solely on the basis of the different boiling points of the substances separated. The high similarity of such separations to those in classic distillation seems advantageous when gas chromatography is used for simulated distillation. This paper presents results from further research on the separation properties of empty fused silica tubing. The efficiency of this chromatographic system has been examined. The usefulness of such conditions has been studied for simulated distillation, i.e. to determine the boiling-point distribution of complex mixtures, mainly petroleum fractions and products, on the basis of their retention relative to reference substances. The results obtained by use of empty-column gas chromatography (EC-GC) and by use of classical simulated distillation columns have been compared for solutes of different polarity. Studies revealed boiling points determined by EC-GC were more accurate than those obtained by the standard method of simulated distillation. PMID:23925798

  8. Simultaneous determination of methamphetamine and its metabolite, amphetamine, in urine using a high performance liquid chromatography column-switching method.

    PubMed

    Kumihashi, Mitsuru; Ameno, Kiyoshi; Shibayama, Takayuki; Suga, Keisuke; Miyauchi, Hiroshi; Jamal, Mostofa; Wang, Weihuan; Uekita, Ikuo; Ijiri, Iwao

    2007-01-01

    We describe here a simple, precise, and highly sensitive method for the simultaneous determination of methamphetamine (MA) and amphetamine (AM) in urine using a high performance liquid chromatography (HPLC) column-switching method. A PK-2A (Shodex) column was used for extraction and deproteinization, and a CAPCELL PAK SCX semi-micro, polymer-coated cation-exchange column was employed for separation. The urine sample was mixed with an equal volume of borate buffer (0.1M, pH 9.4), and then 100 microl of the mixture was injected into the HPLC column. The column was switched for 6 min, and then 10 min later detection was performed at 210 nm. Recovery yields of the MA and AM spiked in the urine were 93.0-100.4% with a coefficient of variation of less than 1%. The calibration curves of MA and AM were in the range of 0.1-10 microg/ml with good linearity (r(2)=0.999), with the limit of qualification being 0.005 microg/ml. This method of using HPLC with column-switching can be used for both qualification and quantification of MA and its metabolite, AM, in urine, especially in forensic cases. PMID:16916628

  9. Radial heterogeneity of some analytical columns used in high-performance liquid chromatography

    SciTech Connect

    Mriziq, Khaled S; Guiochon, Georges A

    2009-01-01

    An on-column electrochemical microdetector was used to determine accurately the radial distribution of the mobile phase velocity and of the column efficiency at the exit of three common analytical columns, namely a 100 mm x 4.6 mm C18 bonded silica-based monolithic column, a 150 mm x 4.6 mm column packed with 2.7 {micro}m porous shell particles of C18 bonded silica (HALO), and a 150 mm x 4.6 mm column packed with 3 {micro}m fully porous C18 bonded silica particles (LUNA). The results obtained demonstrate that all three columns are not radially homogeneous. In all three cases, the efficiency was found to be lower in the wall region of the column than in its core region (the central core with a radius of 1/3 the column inner radius). The decrease in local efficiency from the core to the wall regions was lower in the case of the monolith (ca. 25%) than in that of the two particle-packed columns (ca. 35-50%). The mobile phase velocity was found to be ca. 1.5% higher in the wall than in the core region of the monolithic column while, in contrast, it was ca. 2.5-4.0% lower in the wall region for the two particle-packed columns.

  10. Purification of C70 using charcoal as a stationary phase in a flash chromatography column. Technical report

    SciTech Connect

    Scrivens, W.A.; Cassell, A.M.; Kinsey, K.E.; Tour, J.M.

    1995-06-07

    Described is a method for the purification of C60 and C70 using a flash chromatography column that contains charcoal as the stationary phase. A number of functionalized aromatic solvents are studied and their efficacy for extraction, NMR spectral acquisition, and chromatographic purification of fullerenes is discussed. Ortho-dichlorobenzene was chosen as the best solvent for these applications and examples of its use in the extraction of higher fullerenes (>C84) and in the rapid acquisition of (13)C NMR spectra are given. Finally, single column purification of both C60 and C70 is discussed. Starting with a typical arc-derived mixture of soluble fullerenes, 5.97 g of C60 at >99.9% purity and 1.58 g of C70 at >97% purity were produced in a single column pass.

  11. A closer study of methanol adsorption and its impact on solute retentions in supercritical fluid chromatography.

    PubMed

    Glenne, Emelie; Öhlén, Kristina; Leek, Hanna; Klarqvist, Magnus; Samuelsson, Jörgen; Fornstedt, Torgny

    2016-04-15

    Surface excess adsorption isotherms of methanol on a diol silica adsorbent were measured in supercritical fluid chromatography (SFC) using a mixture of methanol and carbon dioxide as mobile phase. The tracer pulse method was used with deuterium labeled methanol as solute and the tracer peaks were detected using APCI-MS over the whole composition range from neat carbon dioxide to neat methanol. The results indicate that a monolayer (4Å) of methanol is formed on the stationary phase. Moreover, the importance of using the set or the actual methanol fractions and volumetric flows in SFC was investigated by measuring the mass flow respective pressure and by calculations of the actual volume fraction of methanol. The result revealed a significant difference between the value set and the actually delivered volumetric methanol flow rate, especially at low modifier fractions. If relying only on the set methanol fraction in the calculations, the methanol layer thickness should in this system be highly overestimated. Finally, retention times for a set of solutes were measured and related to the findings summarized above concerning methanol adsorption. A strongly non-linear relationship between the logarithms of the retention factors and the modifier fraction in the mobile phase was revealed, prior to the established monolayer. At modifier fractions above that required for establishment of the methanol monolayer, this relationship turns linear which explains why the solute retention factors are less sensitive to changes in modifier content in this region. PMID:26979267

  12. Rapid chemical profiling of saponins in the flower buds of Panax notoginseng by integrating MCI gel column chromatography and liquid chromatography/mass spectrometry analysis.

    PubMed

    Yang, Wen-Zhi; Bo, Tao; Ji, Shuai; Qiao, Xue; Guo, De-An; Ye, Min

    2013-08-15

    The flower buds of Panax notoginseng (Notoginseng flower, FBP) are used as the traditional Chinese medicine San-Qi-Hua. In this study, we conducted column chromatography fractionation and liquid chromatography/mass spectrometry (LC/MS) analysis to comprehensively profile bioactive notoginseng saponins (ginsenosides) in FBP. MCI gel column chromatography allowed separation and enrichment of minor saponins. Electrospray ionization tandem mass spectrometry of [M-H](-) and [M+Na](+) precursor ions of the saponins provided reliable structural information for the sapogenin, and sequence of sugar chains. Confirmed by high-accuracy Q-TOF analysis, 170 notoginseng saponins were characterized from FBP, and 91 of them were reported from Panax species for the first time. The new ginsenosides contain acyl groups on α-chain, malonyl group at 20-OH, or di-malonyl groups. This study also indicated that the flower buds of P. notoginseng contained more protopanaxadiol-type but less protopanaxatriol-type ginsenosides than the roots. PMID:23561171

  13. A fundamental study of the impact of pressure on the adsorption mechanism in reversed-phase liquid chromatography.

    PubMed

    Åsberg, Dennis; Samuelsson, Jörgen; Fornstedt, Torgny

    2016-07-29

    A fundamental investigation of the pressure effect on individual adsorption sites was undertaken based on adsorption energy distribution and adsorption isotherm measurements. For this purpose, we measured adsorption equilibrium data at pressures ranging from 100 to 1000bar at constant flow and over a wide concentration range for three low-molecular-weight solutes, antipyrine, sodium 2-naphthalenesulfonate, and benzyltriethylammonium chloride, on an Eternity C18 stationary phase. The adsorption energy distribution was bimodal for all solutes, remaining clearly so at all pressures. The bi-Langmuir model best described the adsorption in these systems and two types of adsorption sites were identified, one with a low and another with a high energy of interaction. Evidence exists that the low-energy interactions occur at the interface between the mobile and stationary phases and that the high-energy interactions occur nearer the silica surface, deeper in the C18 layer. The contribution of each type of adsorption site to the retention factor was calculated and the change in solute molar volume from the mobile to stationary phase during the adsorption process was estimated for each type of site. The change in solute molar volume was 2-4 times larger at the high-energy site, likely because of the greater loss of solute solvation layer when penetrating deeper into the C18 layer. The association equilibrium constant increased with increasing pressure while the saturation capacity of the low-energy site remained almost unchanged. The observed increase in saturation capacity for the high-energy site did not affect the column loading capacity, which was almost identical at 50- and 950-bar pressure drops over the column. PMID:27357740

  14. Fingerprinting of traditional Chinese medicines on the C18-Diol mixed-mode column in online or offline two-dimensional liquid chromatography on the single column modes.

    PubMed

    Wang, Qing; Tong, Ling; Yao, Lin; Zhang, Peng; Xu, Li

    2016-06-01

    In the present study, a mixed-mode stationary phase, C18-Diol, was applied for fingerprint analysis of traditional Chinese medicines. Hydrophobic, hydrogen bonding and electrostatic interactions were demonstrated to contribute the retention separately or jointly, which endowed the C18-Diol stationary phase with distinct selectivity compared to the bare C18 one. The separation of total alkaloids extracted from Fritillaria hupehensis was compared on the C18-Diol and conventional C18 column with the greater resolving power and better symmetry responses on the former one. Besides, a novel two-dimensional liquid chromatography on the single column (2D-LC-1C) was realized on C18-Diol with the offline mode for the alcohol extract of Fritillaria hupehensis and online mode for Ligusticum chuanxiong Hort. The early co-eluted extracted components with great polarity on the first dimension were reinjected on the same column and well separated on the second dimension. The results exhibited that the two complementary RPLC and HILIC modes on C18-Diol stationary phase enhanced the separation capacity and revealed more abundant chemical information of the sample, which was a powerful tool in analyzing complex herbal medicines. PMID:27031576

  15. Adsorption mechanism in reversed-phase liquid chromatography. Effect of the surface coverage of a monomeric C18-silica stationary phase

    SciTech Connect

    Gritti, Fabrice; Guiochon, Georges A

    2006-04-01

    The effect of the bonding density of the octadecyl chains onto the same silica on the adsorption and retention properties of low molecular weight compounds (phenol, caffeine, and sodium 2-naphthalene sulfonate) was investigated. The same mobile phase (methanol:water, 20:80, v/v) and temperature (T = 298 K) were applied and two duplicate columns (A and B) from each batch of packing material (neat silica, simply endcapped or C{sub 1} phase, 0.42, 1.01, 2.03, and 3.15 {micro}mol/m{sup 2} of C{sub 18} alkyl chains) were tested. Adsorption data of the three compounds were acquired by frontal analysis (FA) and the adsorption energy distributions (AEDs) were calculated using the expectation-maximization method. Results confirmed earlier findings in linear chromatography of a retention maximum at an intermediate bonding density. From a general point of view, the saturation capacity of the adsorbent tends to decrease with increasing bonding density, due to the vanishing space intercalated between the C{sub 18} bonded chains and to the decrease of the specific surface area of the stationary phase. The equilibrium constants are maximum for an intermediary bonding density ({approx}2 {micro}mol/m{sup 2}). An enthalpy-entropy compensation was found for the thermodynamic parameters of the isotherm data. Weak equilibrium constants (small {Delta}H) and high saturation capacities (large {Delta}S) were observed at low bonding densities, higher equilibrium constants and lower saturation capacities at high bonding densities, the combinations leading to similar apparent retention in RPLC. The use of a low surface coverage column is recommended for preparative purposes.

  16. 3D printed titanium micro-bore columns containing polymer monoliths for reversed-phase liquid chromatography.

    PubMed

    Gupta, Vipul; Talebi, Mohammad; Deverell, Jeremy; Sandron, Sara; Nesterenko, Pavel N; Heery, Brendan; Thompson, Fletcher; Beirne, Stephen; Wallace, Gordon G; Paull, Brett

    2016-03-01

    The potential of 3D selective laser melting (SLM) technology to produce compact, temperature and pressure stable titanium alloy chromatographic columns is explored. A micro bore channel (0.9 mm I.D. × 600 mm long) was produced within a 5 × 30 × 30 mm titanium alloy (Ti-6Al-4V) cuboid, in form of a double handed spiral. A poly(butyl methacrylate-co-ethyleneglycoldimethacrylate) (BuMA-co-EDMA) monolithic stationary phase was thermally polymerised within the channel for application in reversed-phase high-performance liquid chromatography. The prepared monolithic column was applied to the liquid chromatographic separation of intact proteins and peptides. Peak capacities of 69-76 (for 6-8 proteins respectively) were observed during isothermal separation of proteins at 44 °C which were further increased to 73-77 using a thermal step gradient with programmed temperature from 60 °C to 35 °C using an in-house built direct-contact heater/cooler platform based upon matching sized Peltier thermoelectric modules. Rapid temperature gradients were possible due to direct-contact between the planar metal column and the Peltier module, and the high thermal conductivity of the titanium column as compared to a similar stainless steel printed column. The separation of peptides released from a digestion of E.coli was also achieved in less than 35 min with ca. 40 distinguishable peaks at 210 nm. PMID:26873472

  17. Simple column-switching ion chromatography method for determining eight monosaccharides and oligosaccharides in honeydew and nectar.

    PubMed

    Ni, Chengzhu; Zhu, Binhe; Wang, Nani; Wang, Muhua; Chen, Suqing; Zhang, Jiajie; Zhu, Yan

    2016-03-01

    Honeydew is excreted by aphids as a sweet waste and nectar is floral honey. Honeydew and nectar are complicated samples which consist of various sugars and amino acids. In this work, a simple ion chromatography with column-switching method was developed for the simultaneous analysis of 8 monosaccharides and oligosaccharides in honeydew and nectar. A reversed-phase column was used as a pretreatment column to eliminate organics on-line and sugars were eluted from a collection loop to analytical column by using column-switching technique. This method showed good linearity (r⩾0.9994) and afforded low limits of detection ranging from 1.55 to 10.17μgL(-1) for all the analytes. Recoveries ranged from 95% to 105% and repeatability results were acceptable with relative standard deviation of less than 3.21% (n=6). This method was successfully applied to quantification of these sugars in honeydew and nectar. These results showed honeydew had much more oligosaccharides than nectar. PMID:26471592

  18. Rapid Screening of Drug-Protein Binding Using High-Performance Affinity Chromatography with Columns Containing Immobilized Human Serum Albumin

    PubMed Central

    Li, Ying-Fei; Zhang, Xiao-Qiong; Hu, Wei-Yu; Li, Zheng; Liu, Ping-Xia; Zhang, Zhen-Qing

    2013-01-01

    For drug candidates, a plasma protein binding (PPB) more than 90% is more meaningful and deserves further investigation in development. In the study, a high-performance liquid chromatography method employing column containing immobilized human serum albumin (HSA) to screen in vitro PPB of leading compounds was established and successfully applied to tested compounds. Good correlation (a coefficient correlation of 0.96) was attained between the reciprocal values (X) of experimentally obtained retention time of reference compounds eluted through HSA column and the reported PPB values (Y) with a correlation equation of Y = 92.03 − 97.01X. The method was successfully applied to six test compounds, and the result was confirmed by the conventional ultrafiltration technique, and both yielded equal results. However, due to the particular protein immobilized to column, the method cannot be applied for all compounds and should be exploited judiciously based on the value of the logarithmic measure of the acid dissociation constant (pKa) as per the requirement. If α1-acid glycoprotein and other plasma proteins could be immobilized like HSA with their actual ratio in plasma to column simultaneously, the result attained using immobilized column may be more accurate, and the method could be applied to more compounds without pKa limitation. PMID:23607050

  19. Displacement chromatography of proteins using a retained pH front in a hydrophobic charge induction chromatography column.

    PubMed

    Pinto, N D S; Frey, Douglas D

    2015-03-27

    The chromatographic separation of two proteins into a displacement train of two adjoined rectangular bands was accomplished using a novel method for hydrophobic charge induction chromatography (HCIC) which employs a self-sharpening pH front as the displacer. This method exploits the fact that protein elution in HCIC is promoted by a pH change, but is relatively independent of salt effects, so that a retained pH front can be used in place of a traditional displacer in displacement chromatography. The retained pH front was produced using the two adsorbed buffering species tricine and acetic acid. The separation of lysozyme and α-chymotrypsinogen A into adjoined, rectangular bands was accomplished with overall recoveries based on the total mass injected greater than 90 and 70%, respectively. The addition of urea to the buffer system increased the sharpness of the pH front by 36% while the yields of lysozyme and α-chymotrypsinogen A based on the total mass eluted increased from 76% to 99% and from 37% to 85%, respectively, when the purities of both proteins in their product fractions were fixed at 85%. The results demonstrate that the method developed in this study is a useful variant of HCIC and is also a useful alternative to other displacement chromatography methods. PMID:25702080

  20. Hydrophilic interaction chromatography of seized drugs and related compounds with sub 2 μm particle columns.

    PubMed

    Lurie, Ira S; Li, Li; Toske, Steven G

    2011-12-30

    The use of hydrophilic interaction chromatography (HILIC) with sub 2 μm particle columns for the analysis of drugs and related compounds of forensic interest is described. This technique uses a high organic/low aqueous buffered mobile phase with a polar stationary phase, and is excellent for the separation of many of the charged solutes that are found in forensic drug exhibits. In this study, HILIC is investigated for 11 solutes of forensic interest, including weak bases, weak acids, and a neutral solute. In addition, for columns containing either ethylene bridged hybrid particles with or without an amide bonded phase, the effects of acetonitrile concentration, buffer type, buffer concentration, linear velocity, and sample concentration were studied. Based on these studies, HILIC with sub 2 μm particle columns can offer highly efficient, selective, and rapid isocratic separations of drugs and related compounds of forensic interest, with excellent peak shapes and low back pressures. This is in contrast to reverse phase chromatography (RPLC), where gradient elution is usually required, which can result in extensive overlap between acidic, neutral, and basic solutes. In addition, since HILIC exhibits a much greater loading capacity than RPLC, it could be a preferred technique for drug profiling. Furthermore, because high organic content mobile phases are highly amenable to mass spectrometric detection, the use of HILIC with tandem mass spectrometric detection for the analysis of seized drugs is described. PMID:22098930

  1. Quasi-adiabatic vacuum-based column housing for very high-pressure liquid chromatography.

    PubMed

    Gritti, Fabrice; Gilar, Martin; Jarrell, Joseph A

    2016-07-22

    A prototype vacuum-based (10(-6)Torr) column housing was built to thermally isolate the chromatographic column from the external air environment. The heat transfer mechanism is solely controlled by surface radiation, which was minimized by wrapping the column with low-emissivity aluminum tape. The adiabaticity of the column housing was quantitatively assessed from the measurement of the operational pressure and fluid temperature at the outlet of a 2.1mm×100mm column (sub-2 μm particles). The pressure drop along the column was raised up to 1kbar. The enthalpy balance of the eluent (water, acetonitrile, and one water/acetonitrile mixture, 70/30, v/v) showed that less than 1% of the viscous heat generated by friction of the fluid against the packed bed was lost to the external air environment. Such a vacuum-based column oven minimizes the amplitude of the radial temperature gradients across the column diameter and maximizes its resolving power. PMID:27324623

  2. Detection of radiation-induced hydrocarbons in Camembert irradiated before and after the maturing process-comparison of florisil column chromatography and on-line coupled liquid chromatography-gas chromatography

    SciTech Connect

    Schulzki, G.; Spiegelberg, A.; Schreiber, G.A.

    1995-02-01

    The influence of the maturing process on the detection of radiation-induced volatile hydrocarbons in the fat of Camembert has been investigated. Two analytical methods for separation of the hydrocarbon fraction from the lipid were applied: Florisil column chromatography with subsequent gas chromatographic-mass spectrometric (GC-MS) determination as well as on-line coupled liquid chromatography-GC-MS. The maturing process had no influence on the detection of radiation-induced volatiles. Comparable results were achieved with both analytical methods. However, preference is given to the more effective on-line coupled LC-GC method. 17 refs., 5 figs., 2 tabs.

  3. Purification of native and recombinant cobra venom factor using thiophilic adsorption chromatography.

    PubMed

    Kölln, Johanna; Braren, Ingke; Bredehorst, Reinhard; Spillner, Edzard

    2007-01-01

    The complement activating venom component Cobra Venom Factor (CVF) forms a stable CVF-dependent C3 convertase complex, which initiates continuous activation of the complement system, consumes all downstream complement components and obliterates functional complement. Therefore, native CVF is routinely used as decomplementing agent in vivo and in vitro. However, in most countries, CVF and even unfractionated cobra venom are now becoming unavailable due to the CITES agreement. Although CVF is a complex molecule with three disulfide linked polypeptide chains and pronounced glycosylation, recombinant expression of the active molecule in eukaryotic host cells may provide an alternative source. In this study we describe a strategy for the production and efficient isolation of recombinant CVF from supernatant of mammalian cells. Thiophilic adsorption chromatography (TAC), an efficient procedure for purification of the human homologue C3, was evaluated for its suitability regarding purification of both native as well as recombinant CVF. Native CVF could be purified by TAC in a one-step procedure from cobra venom with yields of 92% compared to 35% by conventional approaches. After establishment of stably transfected mammalian cells recombinant CVF could be obtained and enriched from CHO supernatants by TAC to a purity of 73%, and up to 90% if an additional affinity chromatography step was included. Subsequent characterization revealed comparable hemolytic and bystander lysis activity and of rCVF and nCVF. These data demonstrate that the functional expression in mammalian cells in combination with TAC for purification renders rCVF a highly attractive substitute for its native counterpart. PMID:17584174

  4. Chromatography.

    ERIC Educational Resources Information Center

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  5. Type of adsorbent and column height in adsorption process of used cooking oil

    NASA Astrophysics Data System (ADS)

    Hasnelly, Hervelly, Taufik, Yusman; Melany, Ivo Nila

    2015-12-01

    The purpose of this research was to find out the best adsorbent and column height that can adsorb color and soluble impurities substances in used cooking oil. This research was meant for knowledge development of refined cooking oil technology. The used of this research was giving out information on the recycling process of used cooking oil. Research design used 2 × 2 factorial pattern in randomized group design with 6 repetitions. The first factor is adsorbent type (J) that consist of activated carbon (J1) and Zeolit (J2). The second factor is column height (K) with variations of 15 cm (k1) and 20 cm (k2). Chemical analysis parameter are free fatty acid, water content and saponification value. Physical parameter measurement was done on color with Hunter Lab system analysis and viscosity using viscometer method. Chemical analysis result of preliminary research on used cooking oil showed water content of 1,9%, free fatty acid 1,58%, saponification value 130,79 mg KOH/g oil, viscosity 0,6 d Pas and color with L value of -27,60, a value 1,04 and b value 1,54. Result on main research showed that adsorbent type only gave effect on water content whereas column height and its interaction was not gave significant effect on water content. Interaction between adsorbent type (J) and column height (K) gave significant effect to free fatty acid, saponification value, viscosity and color for L, a and b value of recycled cooking oil.

  6. An explanation for differences in the process of colloid adsorption in batch and column studies

    Technology Transfer Automated Retrieval System (TEKTRAN)

    It is essential to understand the mechanisms that control virus and bacteria removal in the subsurface environment to assess the risk of groundwater contamination with fecal microorganisms. This study was conducted to explicitly provide a critical and systematic comparison between batch and column e...

  7. Electrically heated, air-cooled thermal modulator and at-column heating for comprehensive two-dimensional gas chromatography.

    PubMed

    Libardoni, Mark; Waite, J Hunter; Sacks, Richard

    2005-05-01

    An instrument for comprehensive two-dimensional gas chromatography (GCxGC) is described using an electrically heated and air-cooled thermal modulator requiring no cryogenic materials or compressed gas for modulator operation. In addition, at-column heating is used to eliminate the need for a convection oven and to greatly reduce the power requirements for column heating. The single-stage modulator is heated by current pulses from a dc power supply and cooled by a conventional two-stage refrigeration unit. The refrigeration unit, together with a heat exchanger and a recirculating pump, cools the modulator to about -30 degrees C. The modulator tube is silica-lined stainless steel with an internal film of dimethylpolysiloxane. The modulator tube is 0.18 mm i.d. x 8 cm in length. The modulator produces an injection plug width as small as 15 ms. PMID:15859594

  8. Direct probing of chromatography columns by laser-induced fluorescence. Technical progress report, September 1, 1989--February 28, 1993

    SciTech Connect

    McGuffin, V.L.

    1992-12-07

    This report summarizes the progress and accomplishments of this research project from September 1, 1989 to February 28, 1993. During this period, we have accomplished all of the primary scientific objectives of the research proposal: (1) constructed and evaluated a laser-induced fluorescence detection system that allows direct examination of the chromatographic column, (2) examined nonequilibrium processes that occur upon solute injection and elution, (3) examined solute retention in liquid chromatography as a function of temperature and pressure, (4) examined solute zone dispersion in liquid chromatography as a function of temperature and pressure, and (5) developed appropriate theoretical models to describe these phenomena. In each of these studies, substantial knowledge has been gained of the fundamental processes that are responsible for chromatographic separations. In addition to these primary research objectives, we have made significant progress in three related areas: (1) examined pyrene as a fluorescent polarity probe insupercritical fluids and liquids as a function of temperature and pressure, (2) developed methods for the class-selective identification of polynuclear aromatic hydrocarbons in coal-derived fluids by microcolumn liquid chromatography with fluorescence quenching detection, and (3) developed methods for the determination of saturated and unsaturated (including omega-3) fatty acids in fish oil extracts by microcolumn liquid chromatography with laser-induced fluorescence detection. In these studies, the advanced separation and detection techniques developed in our laboratory are applied to practical problems of environmental and biomedical significance.

  9. Ion-Exclusion High-Performance Liquid Chromatography of Aliphatic Organic Acids Using a Surfactant-Modified C18 Column.

    PubMed

    Fasciano, Jennifer M; Mansour, Fotouh R; Danielson, Neil D

    2016-07-01

    Ion exclusion chromatography (IELC) of short chain aliphatic carboxylic acids is normally done using a cation exchange column under standard HPLC conditions but not in the ultra-HPLC (UHPLC) mode. A novel IELC method for the separation of this class of carboxylic acids by either HPLC or UHPLC utilizing a C18 column dynamically modified with sodium dodecyl sulfate has been developed. The sample capacity is estimated to be near 10 mM for a 20 µL injection or 0.2 µmol using a 150 × 4.6 mm column. The optimum mobile phase determined for three standard mixtures of organic acids is 1.84 mM sulfuric acid at pH 2.43 and a flow rate of 0.6 mL/min. Under optimized conditions, a HPLC separation of four aliphatic carboxylic acids such as tartaric, malonic, lactic and acetic can be achieved in under 4 min and in <2 min in the UHPLC mode at 2.1 mL/min. A variety of fruit juice and soft drink samples are analyzed. Stability of the column as measured by the retention order of maleic and fumaric acid is estimated to be ∼4,000 column volumes using HPLC and 600 by UHPLC. Reproducible chromatograms are achieved over at least a 2-month period. This study shows that the utility of a C18 column can be easily extended when needed to IELC under either standard or UHPLC conditions. PMID:27006111

  10. Separation of beta-human chorionic gonadotropin and immunoglobulin G by a miniaturized size exclusion chromatography column

    NASA Astrophysics Data System (ADS)

    Yang, Yongmo; Chae, Junseok

    2009-04-01

    This report describes a miniaturized size exclusion chromatography column that effectively preseparates raw samples for medical point-of-care testing (POCT) devices. The minicolumn is constructed of polydimethylsiloxane fabricated on a glass slide. The minicolumn separates 300 ng/ml of beta-human chorionic gonadotropin (β-hCG) from an immunoglobulin G (IgG)-rich solution (100 μg/ml) in 7.7 min, with 2.23 resolution and 0.018 mm plate height. The complete analyte discrimination shows potential for the sample preparation stage of POCT devices for cancer screening, prognosis, and monitoring.

  11. [Rapid determination of trace iodate using monolithic column ion-pair chromatography coupled with direct conductivity detection].

    PubMed

    Liu, Yuzhen; Yu, Hong; Li, Siwen

    2011-10-01

    A method was developed on a monolithic column for the fast determination of trace iodate (IO(3)- ) by ion-pair chromatography with direct conductivity detection. The analytes were separated using a mobile phase of tetrabutylammonium hydroxide (TBA)-phthalic acid-acetonitrile on a reversed-phase silica-based monolithic column. The effects of eluent, flow rate and column temperature on the retention of iodate were investigated. The optimized chromatographic conditions for the determination of the anion were as follows: 0. 25 mmol/L TBA-0. 18 mmol/L phthalic acid-3% acetonitrile (pH 5.5) as mobile phase, a flow rate of 4.0 mL/min and a column temperature of 30 degrees C. Under the optimal conditions, retention time of iodate was less than 0. 5 min and the baseline separation of iodate was achieved without any interference by other anions (Cl-, NO , SO4(2)-, I- ). The detection limit (S/N= 3) was 0.36 mg/L for IO(3)- . Relative standard deviation (RSD, n = 5) of chromatographic peak area and retention time were 0. 35% and 0. 28%, respectively. The proposed method was applied to the determination of trace iodate in iodized medicine. The spiked recovery of iodate was 96. 4%. The method is rapid, simple, accurate, reliable, and practical. PMID:22268363

  12. Direct enantioseparation of nitrogen-heterocyclic pesticides on cellulose-based chiral column by high-performance liquid chromatography.

    PubMed

    Chai, Tingting; Yang, Wenwen; Qiu, Jing; Hou, Shicong

    2015-01-01

    The enantiomeric separation of eight pesticides including bitertanol (), diclobutrazol (), fenbuconazole (), triticonazole (), imazalil (), triapenthenol (), ancymidol (), and carfentrazone-ethyl () was achieved, using normal-phase high-performance liquid chromatography on two cellulosed-based chiral columns. The effects of isopropanol composition from 2% to 30% in the mobile phase and column temperature from 5 to 40 °C were investigated. Satisfactory resolutions were obtained for bitertanol (), triticonazole (), imazalil () with the (+)-enantiomer eluted first and fenbuconazole () with the (-)-enantiomer eluted first on Lux Cellulose-2 and Lux Cellulose-3. (+)-Enantiomers of diclobutrazol () and triapenthenol () were first eluted on Lux Cellulose-2. (-)-Carfentrazone-ethyl () were eluted first on Lux Cellulose-2 and Lux Cellulose-3 with incomplete separation. Reversed elution orders were obtained for ancymidol (7). (+)-Ancymidol was first eluted on Lux Cellulose-2 while on Lux Cellulose-3 (-)-ancymidol was first eluted. The results of the elution order at different column temperatures suggested that column temperature did not affect the optical signals of the enantiomers. These results will be helpful to prepare and analyze individual enantiomers of chiral pesticides. PMID:25331721

  13. The Binding of Biotin to Sepharose-Avidin Column: Demonstration of the Affinity Chromatography Technique

    ERIC Educational Resources Information Center

    Landman, A. D.; Landman, N. N.

    1976-01-01

    Describes a biochemistry experiment that illustrates the methodology of affinity chromatography by attaching avidin, a glycoprotein in egg white, to a Sepharose matrix in order to bind biotin-containing proteins. (MLH)

  14. Polymethacrylate monolithic columns for hydrophilic interaction liquid chromatography prepared using a secondary surface polymerization.

    PubMed

    Currivan, Sinéad; Macak, Jan M; Jandera, Pavel

    2015-07-10

    Zwitterionic methacrylate based polymeric monolithic columns were prepared in two-step polymerizations, with reduced polymerization times. Characteristic properties such as hydrodynamic permeability, porosity, retention factors, and pore size distribution charts were used for column evaluation. A scaffold column was fabricated by polymerization of poly(lauryl methacrylate-co-tetraethyleneglycol dimethacrylate) and was used without further modification as a support for a poly(N,N-dimethyl-N-methacryloxyethyl-N-(3-sulfopropyl)ammonium betaine-co-bisphenol A glycerolate dimethacrylate) second monolith layer with zwitterionic functionality, for HILIC separations. An additional internal structure was formed by the second monolithic layer. The fabrication procedure was reproducible with RSD<5%. Field emission scanning electron microscopy has also been used to investigate column pore morphology, using a novel technique where the polymeric material is imaged directly, without coverage with a conducting film or particles. The new polar monolithic columns were used for HILIC separations of phenolic acids, flavones, nucleosides, and bases of nucleic acids, with similar efficiencies but different selectivities for zwitterionic methacrylate monolithic columns recently prepared by single step polymerization. PMID:26022313

  15. Characteristics of a column suitable for capacity gradient chromatography with a borate eluent.

    PubMed

    Yamamoto, A; Kodama, S; Matsunaga, A; Inoue, Y; Aoyama, T; Kumagai, Y

    2001-04-01

    In capacity gradient elution, the gradient separation of ionic species is achieved by decreasing the ion-exchange capacity of a column during the course of the separation. Diol-type hydroxy groups on the resin surface form anionic complexes with borate as an eluting reagent. Thus, a chemically bonded anion-exchange column enriched with residual hydroxy groups allows the creation of a capacity gradient. An increase in the amount of the complex formed gradually brings about a decrease in the ion-exchange capacity of the column, and strongly bound analyte ions are eluted. We investigated the characteristics of a column suitable for this eluent system. The concentration of borate eluent required to remove the ion-exchange capacity depended inversely on the ratio of the residual hydroxy groups to functional groups. On a column in which this ratio was approximately 100, the ion-exchange capacity could easily be adjusted by using a low concentration of mannitol as a competing reagent. Use of this column led to very small baseline shifts during the borate-mannitol gradients, and to the simultaneous determination of anions with widely varying retention times. PMID:11340979

  16. Affinity-based screening of combinatorial libraries using automated, serial-column chromatography

    SciTech Connect

    Evans, D.M.; Williams, K.P.; McGuinness, B.

    1996-04-01

    The authors have developed an automated serial chromatographic technique for screening a library of compounds based upon their relative affinity for a target molecule. A {open_quotes}target{close_quotes} column containing the immobilized target molecule is set in tandem with a reversed-phase column. A combinatorial peptide library is injected onto the target column. The target-bound peptides are eluted from the first column and transferred automatically to the reversed-phase column. The target-specific peptide peaks from the reversed-phase column are identified and sequenced. Using a monoclonal antibody (3E-7) against {beta}-endorphin as a target, we selected a single peptide with sequence YGGFL from approximately 5800 peptides present in a combinatorial library. We demonstrated the applicability of the technology towards selection of peptides with predetermined affinity for bacterial lipopolysaccharide (LPS, endotoxin). We expect that this technology will have broad applications for high throughput screening of chemical libraries or natural product extracts. 21 refs., 4 figs.

  17. Cr(III) removal from aqueous solutions: a straightforward model approaching of the adsorption in a fixed-bed column.

    PubMed

    Dorado, Antonio David; Gamisans, Xavier; Valderrama, Cesar; Solé, Montse; Lao, Conxita

    2014-01-01

    Prediction of breakthrough curves for continuous sorption characterization is generally performed by means of simple and simplified equations. These expressions hardly have any physical meaning and, also do not allow extrapolation. A novel and simple approach, based on unsteady state mass balances, is presented herein for the simulation of the adsorption of Cr(III) ions from aqueous onto a low-cost adsorbent (leonardite). The proposed model overcomes the limitations of the commonly used analytical solution-based models without the need for complex mathematical methods. A set of experimental breakthrough curves obtained from lab-scale, fixed-bed columns was used to calibrate and validate the proposed model with a minimum number of parameters to be adjusted. PMID:24171417

  18. Adsorption and transformation of ammonium ion in a loose-pore geothermal reservoir: Batch and column experiments

    NASA Astrophysics Data System (ADS)

    Zhao, Li; Li, Yanli; Wang, Shidong; Wang, Xinyi; Meng, Hongqi; Luo, Shaohe

    2016-09-01

    Adsorption kinetics and transformation process of ammonium ion (NH4+) were investigated to advance the understanding of N cycle in a low-temperature loose-pore geothermal reservoir. Firstly, batch experiments were performed in order to determine the sorption capacity and the kinetic mechanism of NH4+ onto a loose-pore geothermal reservoir matrix. Then column experiments were carried out at temperatures from 20 °C to 60 °C in order to determine the transport parameters and transformation mechanism of NH4+ in the studied matrix. The results showed that the adsorption process of NH4+ onto the porous media well followed the pseudo-second-order model. No obvious variation of hydrodynamic dispersion coefficient (D) and retardation factor (R) was observed at different transport distances at a Darcy's flux of 2.27 cm/h, at which nitrification could be neglected. The simulated D obtained by the CDE model in CXTFIT2.1 increased with temperature while R decreased with temperature, indicating that the adsorption capacity of NH4+ onto the matrix decreased with the increasing of temperature. When the Darcy's flux was decreased to 0.014 cm/h, only a little part of NH4+ could be transformed to nitrate, suggesting that low density of nitrifiers existed in the simulated loose-pore geothermal reservoir. Although nitrification rate increased with temperature in the range of 20 °C to 60 °C, it was extremely low and no accumulation of nitrite was observed under the simulated low-temperature geothermal conditions without addition of biomass and oxygen.

  19. Adsorption and transformation of ammonium ion in a loose-pore geothermal reservoir: Batch and column experiments.

    PubMed

    Zhao, Li; Li, Yanli; Wang, Shidong; Wang, Xinyi; Meng, Hongqi; Luo, Shaohe

    2016-09-01

    Adsorption kinetics and transformation process of ammonium ion (NH4(+)) were investigated to advance the understanding of N cycle in a low-temperature loose-pore geothermal reservoir. Firstly, batch experiments were performed in order to determine the sorption capacity and the kinetic mechanism of NH4(+) onto a loose-pore geothermal reservoir matrix. Then column experiments were carried out at temperatures from 20°C to 60°C in order to determine the transport parameters and transformation mechanism of NH4(+) in the studied matrix. The results showed that the adsorption process of NH4(+) onto the porous media well followed the pseudo-second-order model. No obvious variation of hydrodynamic dispersion coefficient (D) and retardation factor (R) was observed at different transport distances at a Darcy's flux of 2.27cm/h, at which nitrification could be neglected. The simulated D obtained by the CDE model in CXTFIT2.1 increased with temperature while R decreased with temperature, indicating that the adsorption capacity of NH4(+) onto the matrix decreased with the increasing of temperature. When the Darcy's flux was decreased to 0.014cm/h, only a little part of NH4(+) could be transformed to nitrate, suggesting that low density of nitrifiers existed in the simulated loose-pore geothermal reservoir. Although nitrification rate increased with temperature in the range of 20°C to 60°C, it was extremely low and no accumulation of nitrite was observed under the simulated low-temperature geothermal conditions without addition of biomass and oxygen. PMID:27356192

  20. Comparison of chromatographic band profiles obtained under microwave irradiated and non-irradiated reversed-phase liquid chromatography column

    SciTech Connect

    Galinada, Wilmer; Guiochon, Georges A

    2005-08-01

    The possible influence of the application of microwave energy to a reversed-phase liquid chromatography column on the mass transfer kinetics and the thermodynamics of equilibrium between mobile and stationary phases was examined. Chromatograms of propylbenzene and phenol were recorded under the same experimental conditions, on the same column, successively irradiated and not. The effect of microwave irradiation on the mass transfer kinetics was determined by measuring the second moment of small pulses of propylbenzene in a 70:30 (v/v) solution of methanol in water and microwave outputs of 15 and 30 W. The effect of microwave irradiation on the equilibrium thermodynamics was determined by measuring the elution time of breakthrough curves of phenol at high concentrations in a 20:80 (v/v) solution of methanol and water and microwave outputs of 15, 50, and 150 W. A qualitative comparison of the profiles of the propylbenzene peaks obtained with and without irradiation suggests that this irradiation affects significantly the peak shapes. However, a qualitative comparison of the profiles of the breakthrough curves of phenol obtained with and without irradiation suggests that this irradiation has no significant effect on their shapes. The peak sharpening observed may be due to an increase in the diffusivity, resulting from the dielectric polarization under microwave irradiation. This effect is directly related to an increase of the rate of mass transfers in the column. In contrast, the similarity of the overloaded band profiles at high concentrations suggests that the equilibrium thermodynamics is unaffected by microwave irradiation. This may be explained by the transparence of the stationary phase to microwaves at 2.45 GHz. The column temperature was measured at the column outlet under irradiation powers of 15, 30, 50, and 150 W. It increases with increasing power, the corresponding effluent temperatures being 25 {+-} 1, 30 {+-} 1, 35 {+-} 1, and 45 {+-} 1 C, respectively.

  1. Generating multiple independent retention index data in dual-secondary column comprehensive two-dimensional gas chromatography.

    PubMed

    Bieri, Stefan; Marriott, Philip J

    2006-12-01

    A method producing simultaneously three retention indexes for compounds has been developed for comprehensive two-dimensional gas chromatography by using a dual secondary column approach (GC x 2GC). For this purpose, the primary flow of the first dimension column was equally diverted into two secondary microbore columns of identical geometry by means of a three-way flow splitter positioned after the longitudinally modulated cryogenic system. This configuration produced a pair of comprehensive two-dimensional chromatograms and generated retention data on three different stationary phases in a single run. First dimension retention indexes were determined on a polar SolGel-Wax column under linear programmed-temperature conditions according to the van den Dool approach using primary alcohol homologues as the reference scale. Calculation of pseudoisothermal retention indexes in both second dimensions was performed on low-polarity 5% phenyl equivalent polysilphenylene/siloxane (BPX5) and 14% cyanopropylphenyl/86% dimethylpolysiloxane (BP10) columns. To construct a retention correlation map in the second dimension separation space upon which KovAts indexes can be derived, two methods exploiting "isovolatility" relationships of alkanes were developed. The first involved 15 sequential headspace samplings of selected n-alkanes by solid-phase microextraction (SPME), with each sampling followed by their injection into the GC at predetermined times during the chromatographic run. The second method extended the second dimension retention map and consisted of repetitive introduction of SPME-sampled alkane mixtures at various isothermal conditions incremented over the temperature program range. Calculated second dimension retention indexes were compared with experimental values obtained in conventional one-dimensional GC. A case study mixture including 24 suspected allergens (i.e., fragrance ingredients) was used to demonstrate the feasibility and potential of retention index

  2. Characterization of a multiple endogenously expressed Adenosine triphosphate-Binding Cassette transporters using nuclear and cellular membrane affinity chromatography columns

    PubMed Central

    Khadeer, M.A.; Shimmo, R.; Wainer, I.W.; Moaddel, R.

    2014-01-01

    Glioblastoma multiforme is an aggressive form of human astrocytoma, with poor prognosis due to multi-drug resistance to a number of anticancer drugs. The observed multi-drug resistance is primarily due to the efflux activity of ATP Binding Cassette (ABC) efflux transporters such as Pgp, MRP1 and BCRP. The expression of these transporters has been demonstrated in nuclear and cellular membranes of the LN-229 human glioblastoma cell line. Nuclear membrane and cellular membrane fragments from LN229 cells were immobilized on the IAM stationary phase to create nuclear and cellular membrane affinity chromatography columns, (NMAC(LN229)) and (CMAC(LN229)), respectively. Pgp, MRP1and BCRP transporters co-immobilized on both columns was characterized and compared by establishing the binding affinities for estrone-3-sulfate (3.8 vs 3.7μM), verapamil (0.6 vs 0.7μM) and prazosin (0.099 vs 0.033μM) on each column and no significant differences were observed. Since the marker ligands had overlapping selectivities, the selective characterization of each transporter was carried out by saturation of the binding sites of the non-targeted transporters. The addition of verapamil (Pgp and MRP1 substrate) to the mobile phase allowed the comparative screening of 8 compounds at the nuclear and cellular BCRP using etoposide as the marker ligand. AZT increased the retention of etoposide (+15%), a positive allosteric interaction, on the CMAC(LN229) column and decreased it (−5%) on the NMAC(LN229), while the opposite effect was produced by rhodamine. The results indicate that there are differences between the cellular and nuclear membrane expressed BCRP and that NMAC and CMAC columns can be used to probe these differences. PMID:24642394

  3. Effects of Humidity Swings on Adsorption Columns for Air Revitalization: Modeling and Experiments

    NASA Technical Reports Server (NTRS)

    LeVan, M. Douglas; Finn, John E.

    1997-01-01

    The goal of this research was to develop a dynamic model which can predict the effect of humidity swings on activated carbon adsorption beds used to remove trace contaminants from the atmosphere in spacecraft. Specifically, the model was to be incorporated into a computer simulation to predict contaminant concentrations exiting the bed as a function of time after a humidity swing occurs. Predicted breakthrough curves were to be compared to experimentally measured results. In all respects the research was successful. The two major aspects of this research were the mathematical model and the experiments. Experiments were conducted by Mr. Appel using a fixed-bed apparatus at NASA-Ames Research Center during the summers of 1994 and 1995 and during the first 8 months of 1996. Mr. Appel conducted most of his mathematical modeling work at the University of Virginia. The simulation code was used to predict breakthrough curves using adsorption equilibrium correlations developed previously by M. D. LeVan's research group at the University of Virginia. These predictions were compared with the experimental measurements, and this led to improvements in both the simulation code and the apparatus.

  4. Gas chromatography-mass spectrometry in the investigation of on-column dehydration of steroid hormones during gas-liquid chromatography.

    PubMed

    Trafford, D J; Coldwell, R D; Makin, H L

    1991-01-01

    Some underivatized steroids when injected onto conventional packed columns for gas-liquid chromatography underwent varying degrees of dehydration. This problem was traced to the presence of small pieces of broken glass on the top of the column at the point of injection. This observation provoked an examination of the effect of pre-column dehydration on a number of different types of steroids. Powdered aluminium was placed in the injection liner of a Hewlett-Packard gas chromatograph fitted with an HP1 capillary column connected to a mass selective detector, and injections were made using a new high temperature septumless injection system at temperatures between 200 and 400 degrees C. 5 alpha-androstan-3 alpha-ol, a simple monofunctional C19 steroid chosen as a model to establish optimum conditions, underwent dehydration at injection temperatures greater than 250 degrees C and the product reached a maximum at 400 degrees C when no unchanged steroid was present. Monohydroxylated androgens and oestrogens underwent dehydration at 400 degrees C producing products whose mass spectra indicated they were monenes, although the position of the double bond could not be assigned. Polyfunctional androgens and oestrogens and corticosteroids underwent complex changes producing a number of products some of whose structures could not be determined. The dehydration products had the advantage that they had relatively intense high mass ions and for suitable steroids this might provide enhanced sensitivity of detection during mass fragmentography. In such cases dehydration was reproducible and straight line standard curves were obtained. C27 and C28 secosteroids (vitamins D2 and D3) and some of their metabolites (e.g. 25-hydroxyvitamin D) underwent efficient dehydration, again producing products with intense molecular ions. In the case of 24,25-dihydroxyvitamin D3 and 25,26-dihydroxyvitamin D3, dehydration produced different products which were easily resolved in the chromatographic

  5. Problems in the size exclusion chromatography of poly( N-isopropylacrylamide) on styragel columns

    NASA Astrophysics Data System (ADS)

    Estrin, Ya. I.; Perepelitsina, E. O.; Grishchuk, A. A.

    2016-07-01

    The molecular weights of poly( N-isopropylacrylamide) (PNIPA), calculated according to polystyrene calibration standards upon the elution of THF on styragel columns, appear to be much lower than their actual values determined using independent approaches. This is likely due to interactions between the nitrogen-containing units of PNIPA polymer chains and the sorbent, so the polymer is eluted in the mode intermediate between exclusion and critical. An effective exclusion mode during the elution of PNIPA on a styragel column can be achieved by using an eluent more polar than tetrahydrofuran (particularly, 1-methylpyrrolidone).

  6. Semi-Automated Hydrophobic Interaction Chromatography Column Scouting Used in the Two-Step Purification of Recombinant Green Fluorescent Protein

    PubMed Central

    Murphy, Patrick J. M.

    2014-01-01

    Background Hydrophobic interaction chromatography (HIC) most commonly requires experimental determination (i.e., scouting) in order to select an optimal chromatographic medium for purifying a given target protein. Neither a two-step purification of untagged green fluorescent protein (GFP) from crude bacterial lysate using sequential HIC and size exclusion chromatography (SEC), nor HIC column scouting elution profiles of GFP, have been previously reported. Methods and Results Bacterial lysate expressing recombinant GFP was sequentially adsorbed to commercially available HIC columns containing butyl, octyl, and phenyl-based HIC ligands coupled to matrices of varying bead size. The lysate was fractionated using a linear ammonium phosphate salt gradient at constant pH. Collected HIC eluate fractions containing retained GFP were then pooled and further purified using high-resolution preparative SEC. Significant differences in presumptive GFP elution profiles were observed using in-line absorption spectrophotometry (A395) and post-run fluorimetry. SDS-PAGE and western blot demonstrated that fluorometric detection was the more accurate indicator of GFP elution in both HIC and SEC purification steps. Comparison of composite HIC column scouting data indicated that a phenyl ligand coupled to a 34 µm matrix produced the highest degree of target protein capture and separation. Conclusions Conducting two-step protein purification using the preferred HIC medium followed by SEC resulted in a final, concentrated product with >98% protein purity. In-line absorbance spectrophotometry was not as precise of an indicator of GFP elution as post-run fluorimetry. These findings demonstrate the importance of utilizing a combination of detection methods when evaluating purification strategies. GFP is a well-characterized model protein, used heavily in educational settings and by researchers with limited protein purification experience, and the data and strategies presented here may aid in

  7. Sugar Determination in Foods with a Radially Compressed High Performance Liquid Chromatography Column.

    ERIC Educational Resources Information Center

    Ondrus, Martin G.; And Others

    1983-01-01

    Advocates use of Waters Associates Radial Compression Separation System for high performance liquid chromatography. Discusses instrumentation and reagents, outlining procedure for analyzing various foods and discussing typical student data. Points out potential problems due to impurities and pump seal life. Suggests use of ribose as internal…

  8. [Determination of trace carbaryl and carbofuran in water by online column enrichment-ultra high performance liquid chromatography].

    PubMed

    Wang, Enzhi; Yang, Xinlei; Ye, Mingli; Wang, Qiong; Cai, Xiaojun

    2011-11-01

    An online column enrichment-ultra high performance liquid chromatography (UHPLC) method was developed to determine trace carbaryl and carbofuran in water. The sample was injected into a UHPLC system directly after filtration with 0.22 microm membrane, and then enriched by online solid phase extraction (SPE) column. The analyte was back-flushed into the analytical column Acclaim RSLC C18 (100 mm x 2.1 mm, 2.2 microm) by valve switching method. The mobile phases were 10 mmol/L ammonium acetate buffer (pH 5.0, adjusted by acetic acid) and acetonitrile in a gradient elution mode with a flow rate of 0.8 mL/min, and detected by a diode array detector with the detection wavelength of 280 nm. The good linear ranges of carbaryl and carbofuran were 1.0 - 100 microg/L with the correlation coefficients (r2) larger than 0.9999, and the limits of detection (S/N = 3) were 0.5 microg/L and 0.25 microg/L, respectively. The average spiked recoveries were in the range of 76.0% - 120.0%. The method has been applied to determine trace carbaryl and carbofuran in water samples with satisfactory results. PMID:22393707

  9. On-column nitrosation of amines observed in liquid chromatography impurity separations employing ammonium hydroxide and acetonitrile as mobile phase.

    PubMed

    Myers, David P; Hetrick, Evan M; Liang, Zhongming; Hadden, Chad E; Bandy, Steven; Kemp, Craig A; Harris, Thomas M; Baertschi, Steven W

    2013-12-01

    The availability of high performance liquid chromatography (HPLC) columns capable of operation at pH values up to 12 has allowed a greater selectivity space to be explored for method development in pharmaceutical analysis. Ammonium hydroxide is of particular value in the mobile phase because it is compatible with direct interfacing to electrospray mass spectrometers. This paper reports an unexpected N-nitrosation reaction that occurs with analytes containing primary and secondary amines when ammonium hydroxide is used to achieve the high pH and acetonitrile is used as the organic modifier. The nitrosation reaction has generality. It has been observed on multiple columns from different vendors and with multiple amine-containing analytes. Ammonia was established to be the source of the nitroso nitrogen. The stainless steel column frit and metal ablated from the frit have been shown to be the sites of the reactions. The process is initiated by removal of the chromium oxide protective film from the stainless steel by acetonitrile. It is hypothesized that the highly active, freshly exposed metals catalyze room temperature oxidation of ammonia to NO but that the actual nitrosating agent is likely N(2)O(3). PMID:24182763

  10. Determination of a major metabolite of tipredane in rat urine by high-performance liquid chromatography with column switching.

    PubMed

    Baker, P R; Bayliss, M A; Wilkinson, D

    1997-06-20

    An automated method, based on column-switching reversed-phase high-performance liquid chromatography, has been developed for the determination of a major metabolite of tipredane in rat urine. Samples are injected directly onto a cyanopropyl extraction column. The portion of eluate containing the metabolite is switched, via an injection loop, onto an octadecylsilane analytical column. The limit of quantification of the method was 25 ng/ml for a 20 microl injection volume of urine. The intra-assay precision (0.7-4.8%) and accuracy (94-105%), and the inter-assay precision (2.7-12.6%) and accuracy (94-105%), were acceptable. The analyte was found to be stable in rat urine when stored at room temperature for six days, in a freezer at or below -20 degrees C for twelve weeks, and when the samples were subjected to two freeze-thaw cycles. No significant interference was observed from tipredane and its major human metabolites, or urine constituents in male and female rats. The method was successfully used to analyse samples from a long-term toxicology study. PMID:9234863

  11. Coupling Isotachophoresis with Affinity Chromatography for Rapid and Selective Purification with High Column Utilization, Part 1: Theory

    PubMed Central

    2015-01-01

    We present a novel technique that couples isotachophoresis (ITP) with affinity chromatography (AC) to achieve rapid, selective purification with high column utilization. ITP simultaneously preconcentrates an analyte and purifies it, based on differences in mobility of sample components, excluding species that may foul or compete with the target at the affinity substrate. ITP preconcentration accelerates the affinity reaction, reducing assay time, improving column utilization, and allowing for capture of targets with higher dissociation constants. Furthermore, ITP-AC separates the target and contaminants into nondiffusing zones, thus achieving high resolution in a short distance and time. We present an analytical model for spatiotemporal dynamics of ITP-AC. We identify and explore the effect of key process parameters, including target distribution width and height, ITP zone velocity, forward and reverse reaction constants, and probe concentration on necessary affinity region length, assay time, and capture efficiency. Our analytical approach shows collapse of these variables to three nondimensional parameters. The analysis yields simple analytical relations for capture length and capture time in relevant ITP-AC regimes, and it demonstrates how ITP greatly reduces assay time and improves column utilization. In the second part of this two-part series, we will present experimental validation of our model and demonstrate ITP-AC separation of the target from 10,000-fold more-abundant contaminants. PMID:24937679

  12. Evaluation of column carryover of phosphorylated peptides and fumonisins by duplicated solvent gradient method in liquid chromatography/tandem mass spectrometry.

    PubMed

    Sakamaki, Hiroshi; Uchida, Takeharu; Lim, Lee Wah; Takeuchi, Toyohide

    2015-01-01

    Columns made of three different materials were evaluated with regard to the carryover of phosphorylated peptides and fumonisins in liquid chromatography/tandem mass spectrometry (LC/MS/MS). In order to eliminate carryover caused by the injection operation in the autosampler, the column carryover was calculated using the duplicated solvent gradient method. A column made of a glass-lined stainless-steel tube and polyethylene frits (GL-PE column) yielded the most significant improvements in the peak shape and the carryover as compared to the other columns. The carryover of fumonisin B1 (FB1) and HLADLSpK (T19p) in the GL-PE column could be reduced; the lower limit of quantitation of T19p, and the range of the calibration curve were also improved. Since carryover peaks with the GL-PE column were symmetrical peaks of the samples, carryover in the column did not occur. The carryover calculated by the duplicated solvent gradient method corresponded to those in the flow path from the injection port to the inlet frit of the column. The carryover value of FB1 in the column with a stainless-steel tube and stainless-steel frits (S-S column) was 1.70%, and that of the flow path was 0.23%. We found that the majority of the carryover in our system occurred in the S-S column. PMID:25746806

  13. Adsorption of water from aqueous acetonitrile on silica-based stationary phases in aqueous normal-phase liquid chromatography.

    PubMed

    Soukup, Jan; Jandera, Pavel

    2014-12-29

    Excess adsorption of water from aqueous acetonitrile mobile phases was investigated on 16 stationary phases using the frontal analysis method and coulometric Karl-Fischer titration. The stationary phases include silica gel and silica-bonded phases with different polarities, octadecyl and cholesterol, phenyl, nitrile, pentafluorophenylpropyl, diol and zwitterionic sulfobetaine and phosphorylcholine ligands bonded on silica, hybrid organic-silica and hydrosilated matrices. Both fully porous and core-shell column types were included. Preferential uptake of water by the columns can be described by Langmuir isotherms. Even though a diffuse rather than a compact adsorbed discrete layer of water on the adsorbent surface can be formed because of the unlimited miscibility of water with acetonitrile, for convenience, the preferentially adsorbed water was expressed in terms of a hypothetical monomolecular water layer equivalent in the inner pores. The uptake of water strongly depends on the polarity and type of the column. Less than one monomolecular water layer equivalent was adsorbed on moderate polar silica hydride-based stationary phases, Ascentis Express F5 and Ascentis Express CN column at the saturation capacity, while on more polar stationary phases, several water layer equivalents were up-taken from the mobile phase. The strongest affinity to water was observed on the ZIC cHILIC stationary phases, where more than nine water layer equivalents were adsorbed onto its surface at its saturation capacity. Columns with bonded hydroxyl and diol ligands show stronger water adsorption in comparison to bare silica. Columns based on hydrosilated silica generally show significantly decreased water uptake in comparison to stationary phases bonded on ordinary silica. Significant correlations were found between the water uptake and the separation selectivity for compounds with strong polarity differences. PMID:25544246

  14. Artificial neural network (ANN) modeling of adsorption of methylene blue by NaOH-modified rice husk in a fixed-bed column system.

    PubMed

    Chowdhury, Shamik; Saha, Papita Das

    2013-02-01

    In this study, rice husk was modified with NaOH and used as adsorbent for dynamic adsorption of methylene blue (MB) from aqueous solutions. Continuous removal of MB from aqueous solutions was studied in a laboratory scale fixed-bed column packed with NaOH-modified rice husk (NMRH). Effect of different flow rates and bed heights on the column breakthrough performance was investigated. In order to determine the most suitable model for describing the adsorption kinetics of MB in the fixed-bed column system, the bed depth service time (BDST) model as well as the Thomas model was fitted to the experimental data. An artificial neural network (ANN)-based model was also developed for describing the dynamic dye adsorption process. An extensive error analysis was carried out between experimental data and data predicted by the models by using the following error functions: correlation coefficient (R(2)), average relative error, sum of the absolute error and Chi-square statistic test (χ(2)). Results show that with increasing bed height and decreasing flow rate, the breakthrough time was delayed. All the error functions yielded minimum values for the ANN model than the traditional models (BDST and Thomas), suggesting that the ANN model is the most suitable model to describe the fixed-bed adsorption of MB by NMRH. It is also more rational and reliable to interpret dynamic dye adsorption data through a process of ANN architecture. PMID:22562342

  15. Tandem column for the simultaneous determination of arginine, ibuprofen and related impurities by liquid chromatography.

    PubMed

    Huidobro, A L; Rupérez, F J; Barbas, C

    2006-06-30

    Ibuprofen arginate is a rapidly absorbed salt designed to promote more rapid onset of analgesia than commercially available forms of ibuprofen. Ibuprofen and arginine have very different polarities and this becomes in a chromatographic problem, further complicated with the determination of related compounds, which is necessary in stability assays of the pharmaceutical forms. The common solution is the employment of two separate methods, but this is time consuming. A LC method has been developed to determinate both compounds and related impurities in one run. Ibuprofen, arginine and three ibuprofen related impurities (B, E and J) have been baseline separated with isocratic conditions at pH 3.0 and run time under 20 min by employing a tandem combination of two different stationary phases: first a ZORBAX SB-C18 column from Agilent (250 mm x 4.6 mm and 5 microm) and downstream a SUPELCOSIL LC-NH2 column from Supelco (150 mm x 4.6 mm and 3 microm). The octadecyldiisobutylsilane column provides the separation of ibuprofen and its impurities by a hydrophobic mechanism, whereas aminopropyl column offers selective retention of arginine by dipolar interaction mechanism. Method has been successfully validated following ICH guidelines and it has been demonstrated to be reliable for arginine, ibuprofen and related impurities determination in sachets of two different dosages as pharmaceutical forms. Moreover, stress test has proved the selectivity of the method for degradation products, such as those that can emerge throughout long-term stability assays. PMID:16364348

  16. Evaluation of liquid chromatography column retentivity using macromolecular probes. IV. Poly(ethylene glycol) bonded phase.

    PubMed

    Berek, Dusan; Mendichi, Raniero

    2004-02-01

    Interaction properties of the novel HPLC silica gel-poly(ethylene glycol) (PEG) bonded phase were evaluated applying polymeric test substances, viz. polystyrenes, poly(methyl methacrylate)s, poly(ethylene oxide)s and poly(2-vinyl pyridine)s, and eluents of different polarities. Silanols on the silica gel surface are well shielded by the PEG phase, and silanophilic adsorption of macromolecules is suppressed in comparison with most silica C(18) bonded phases. The adsorption of solutes on the -OH groups of the PEG phase seems to be low as well. The partition of macromolecules in favor of the PEG phase is inferior to that observed in case of the silica C(18) phases. The volume of the PEG bonded phase is small and it is supposed that the PEG chains assume flat conformation on the silica gel surface. PMID:14698238

  17. Adsorption mechanism of acids and bases in reversed-phase liquid chromatography in weak buffered mobile phases designed for liquid chromatography/mass spectrometry

    SciTech Connect

    Gritti, Fabrice; Guiochon, Georges A

    2009-01-01

    The overloaded band profiles of five acido-basic compounds were measured, using weakly buffered mobile phases. Low buffer concentrations were selected to provide a better understanding of the band profiles recorded in LC/MS analyses, which are often carried out at low buffer concentrations. In this work, 10 {micro}L samples of a 50 mM probe solution were injected into C{sub 18}-bonded columns using a series of five buffered mobile phases at {sub W}{sup S}pH between 2 and 12. The retention times and the shapes of the bands were analyzed based on thermodynamic arguments. A new adsorption model that takes into account the simultaneous adsorption of the acidic and the basic species onto the endcapped adsorbent, predicts accurately the complex experimental profiles recorded. The adsorption mechanism of acido-basic compounds onto RPLC phases seems to be consistent with the following microscopic model. No matter whether the acid or the base is the neutral or the basic species, the neutral species adsorbs onto a large number of weak adsorption sites (their saturation capacity is several tens g/L and their equilibrium constant of the order of 0.1 L/g). In contrast, the ionic species adsorbs strongly onto fewer active sites (their saturation capacity is about 1 g/L and their equilibrium constant of the order of a few L/g). From a microscopic point of view and in agreement with the adsorption isotherm of the compound measured by frontal analysis (FA) and with the results of Monte-Carlo calculations performed by Schure et al., the first type of adsorption sites are most likely located in between C{sub 18}-bonded chains and the second type of adsorption sites are located deeper in contact with the silica surface. The injected concentration (50 mM) was too low to probe the weakest adsorption sites (saturation capacity of a few hundreds g/L with an equilibrium constant of one hundredth of L/g) that are located at the very interface between the C{sub 18}-bonded layer and the bulk

  18. [Simultaneous determination of iodide and thiocyanate powdered milk using ion chromatography with mixed-mode column].

    PubMed

    Li, Jing; Wang, Yu; Liang, Lina

    2010-04-01

    The contents of iodide and thiocyanate are important detection items in powdered milk quality testing. Due to the complexity of the powdered milk matrix, chromatographic analysis is easily subjected to interference. Acclaim Mixed-Mode WAX-1 column incorporated both hydrophobic and weak anion-exchange properties was used to separate iodide and thiocyanate from interfering substances in powdered milk matrix, and detected by Ultraviolet (UV) detection. After powdered milk was dissolved in water, the protein was precipitated by acetonitrile. Then OnGuard RP pre-treatment column was used to remove the organic matters which might pollute the column. The eluent was acetonitrile-100 mmol/L phosphate buffer (pH 6)-water (45:5:50,v/v/v). The UV detection wavelength was 226 nm. The limits of detection of iodide and thiocyanate were 4.6 microg/L and 13.8 microg/L respectively, and the relative standard deviations of peak areas were 1.2% (n = 6) and 1.7% (n = 6) for 0.2 mg/L iodide and thiocyanate standard solutions. The method is accurate and reliable, and has wide linear range, low limit of detection. This method provides a viable approach for powdered milk quality dairy products. PMID:20712128

  19. Determination of nutrients in the presence of high chloride concentrations by column-switching ion chromatography.

    PubMed

    Bruno, P; Caselli, M; de Gennaro, G; De Tommaso, B; Lastella, G; Mastrolitti, S

    2003-06-27

    Determination of inorganic anions in waters of high salinity is one of the most difficult task in analytical chemistry. A simple column-switching method, based on an original chromatographic set-up, for the determination of nutrients (nitrate, nitrite and phosphate) in chloride rich aqueous matrices is presented. A pre-separation system (made of two in line pre-columns, Dionex AG9-HC 4 mm) connected to an analytical column (Dionex AS9-HC 4 mm) by a four way pneumatic valve, allows chloride to be eluted off into the waste and nutrients to be separated and detected by a conductimeter and/or a UV spectrophotometer. Neither chemical pre-treatment nor sample dilution are required; sample matrices presenting a large range of chloride concentrations can be investigated. Moreover by using this technology, automation for routine analysis, low analysis time and low costs can be achieved. LODs of 100, 300, 1000 microg/l for nitrate, nitrite and phosphate, respectively, have been obtained by spiking a synthetic sea water sample containing 20,000 mg/l of chloride and 3000 mg/l of sulphate. Analyte calibration curves of analytes are linear (r>0.99) in the range between the LODs and 60 mg/l. This method was applied to nutrients determination in sea water samples collected near a river outlet. PMID:12899303

  20. Simple determination of terbutaline in dog plasma by column-switching liquid chromatography.

    PubMed

    Zhang, Y; Zhang, Z R

    2004-06-15

    Terbutaline is a beta-adrenergic receptor antagonist that acts as a bronchodilator in the treatment of asthma and chronic bronchitis. In the present work, a column-switching high-performance liquid chromatographic method was developed to monitor terbutaline sulphate in dog plasma. The system consists of a C2 pre-column (PC) and a C18 analytical column connected in series via a switching valve. Atenolol was used as the internal standard. Good linearity was achieved in the range of 5-800 ng/ml plasma. The mean intra- and inter-assay variation coefficients for this analysis were 2.3 and 4.7%, respectively. The average recovery for terbutaline was 87.4% from plasma. The mean concentration after three freeze-thaw cycles was 99.4% of the normal value. The analytical sensitivity and accuracy of this assay is adequate for characterisation of the pharmacokinetics of oral administration of terbutaline to dogs and has been successfully used to provide pharmacokinetic data using pulsatile and immediate-release tablets. PMID:15135092

  1. Study of an electroosmotic pump for liquid delivery and its application in capillary column liquid chromatography.

    PubMed

    Chen, Lingxin; Ma, Jiping; Guan, Yafeng

    2004-03-01

    A packed-bed electroosmotic pump (EOP) was constructed and evaluated. The EOP consisted of three capillary columns packed in parallel, a gas-releasing device, Pt electrodes and a high-voltage power supply. The EOP could generate output pressure above 5.0 MPa and constant flow rate in the range of nl/min to a few microl/min for pure water, pure methanol, 2 mM potassium dihydrogenphosphate buffer, the buffer-methanol mixture and the pure water-methanol mixture at applied potentials less than 20 kV. The composition of solvent before/after pumping was quantitatively determined by using a gas chromatograph equipped with both flame ionization detector and thermal conductivity detector. It was found that there were no apparent changes in composition and relative concentrations after pumping process for a methanol-ethanol-acetonitrile mixture and a methanol-water mixture. Theoretical aspect of the EOP was discussed in detail. An capillary HPLC system consisting of the EOP, an injection valve, a 15 cm x 320 microm i.d., 5 microm Spherigel C18 stainless steel analytical column, and an on-column UV detector was connected to evaluate the performance of the EOP. A comparative study was also carried out with a mechanical capillary HPLC pump on the same system. The results demonstrated that the reproducibility of flow rate and the pulsation-free flow property of the EOP are superior to that of mechanical pump in capillary HPLC application. PMID:14989475

  2. Evolution in miniaturized column liquid chromatography instrumentation and applications: An overview.

    PubMed

    Nazario, Carlos E D; Silva, Meire R; Franco, Maraíssa S; Lanças, Fernando M

    2015-11-20

    The purpose of this article is to underline the miniaturized LC instrumental system and describe the evolution of commercially available systems by discussing their advantages and drawbacks. Nowadays, there are already many miniaturized LC systems available with a great variety of pump design, interface and detectors as well as efficient columns technologies and reduced connections devices. The solvent delivery systems are able to drive the mobile phase without flow splitters and promote gradient elution using either dual piston reciprocating or syringe-type pumps. The mass spectrometry as detection system is the most widely used detection system; among many alternative ionization sources direct-EI LC-MS is a promising alternative to APCI. In addition, capillary columns are now available showing many possibilities of stationary phases, inner diameters and hardware materials. This review provides a discussion about miniaturized LC demonstrating fundamentals and instrumentals' aspects of the commercially available miniaturized LC instrumental system mainly nano and micro LC formats. This review also covers the recent developments and trends in instrumentation, capillary and nano columns, and several applications of this very important and promising field. PMID:26381569

  3. Simultaneous Production and Recovery of Fumaric Acid from Immobilized Rhizopus oryzae with a Rotary Biofilm Contactor and an Adsorption Column

    PubMed Central

    Cao, N.; Du, J.; Gong, C. S.; Tsao, G. T.

    1996-01-01

    An integrated system of simultaneous fermentation-adsorption for the production and recovery of fumaric acid from glucose by Rhizopus oryzae was investigated. The system was constructed such that growing Rhizopus mycelia were self-immobilized on the plastic discs of a rotary biofilm contactor during the nitrogen-rich growth phase. During the nongrowth, production phase, the biofilm was alternately exposed to liquid medium and air upon rotation of the discs in the horizontal fermentation vessel. The product of fermentation, fumaric acid, was removed simultaneously and continuously by a coupled adsorption column, thereby moderating inhibition, enhancing the fermentation rate, and sustaining cell viability. Another beneficial effect of the removal of fumaric acid is release of hydroxyl ions from a polyvinyl pyridine adsorbent into the circulating fermentation broth. This moderates the decrease in pH that would otherwise occur. Polyvinyl pyridine and IRA-900 gave the highest loading for this type of fermentation. This fermentation system is capable of producing fumaric acid with an average yield of 85 g/liter from 100 g of glucose per liter within 20 h under repetitive fed-batch cycles. On a weight yield basis, 91% of the theoretical maximum was obtained with a productivity of 4.25 g/liter/h. This is in contrast to stirred-tank fermentation supplemented with calcium carbonate, whose average weight yield was 65% after 72 h with a productivity of 0.9 g/liter/h. The immobilized reactor was operated repetitively for 2 weeks without loss of biological activity. PMID:16535381

  4. Modern analytical supercritical fluid chromatography using columns packed with sub-2 μm particles: a tutorial.

    PubMed

    Nováková, Lucie; Perrenoud, Alexandre Grand-Guillaume; Francois, Isabelle; West, Caroline; Lesellier, Eric; Guillarme, Davy

    2014-05-01

    This tutorial provides an overview of the possibilities, limitations and analytical conditions of modern analytical supercritical fluid chromatography (SFC) using columns packed with sub-2 μm particles. In particular, it gives a detailed overview of commercially available modern SFC instrumentation and the detectors that can be employed (UV, MS, ELSD, FID, etc.). Some advice on the choice of the stationary phase dimensions and chemistries, the nature of the mobile phase (choice of organic modifier and additives) and its flow rate as well as the backpressure and temperature are also provided. Finally, several groups of potentially problematic compounds, including lipophilic compounds, hydrophilic substances and basic drugs, are discussed in detail. All these families of analytes can be resolved with SFC but require specific analytical conditions. PMID:24759745

  5. Five-column chromatography separation for simultaneous determination of hard-to-detect radionuclides in water and swipe samples.

    PubMed

    Dai, Xiongxin; Kramer-Tremblay, Sheila

    2014-06-01

    There is a growing demand for the rapid determination of hard-to-detect radionuclides in environmental and biological samples for environmental monitoring, radiological protection, and nuclear forensic reasons. A new method using five-column chromatography separation has been developed for the simultaneous determination of Pu, Np, Th, U, Am, Cm, Pm, Y, and Sr isotopes, as well as iron-55, by inductively coupled mass spectrometry (ICPMS), α spectrometry, Čerenkov and liquid scintillation (LS) counting. Spiked swipe and water samples as well as proficient testing water standards were analyzed to validate the separation procedure, and the results are in good agreement with the expected values. The method provides quick sample turnaround time and high analysis throughput with low analysis cost. The flexibility of the method also allows for its easy adaptation to various emergency and routine radioassays. PMID:24802776

  6. Removal of BPA model compounds and related substances by means of column chromatography using Octolig®.

    PubMed

    Alessio, Rachael J; Li, Xiao; Martin, Dean F

    2012-01-01

    Octolig®, a polyethylenediimine ligand covalently attached to high-surface area silica gel, was used to study the removal of phenolic compounds from aqueous samples by column chromatography. Model phenolic compounds of Bisphenol A (BPA), 4-isopropylphenol and 4-(t-butyl) phenol, were selected for this study due to their similarities in pKa and log P values. The percent removal of these compounds by Octolig® was 26 ± 2 and 22 ± 2, respectively. Furthermore, the three isomers of nitrophenol were investigated as well as additional phenolic compounds, such as amoxicillin and five phenolic dyes. These compounds have a pKa range of 2-10.2. The compounds that have pKa values less than 8.3 were able to be completely removed by Octolig®, yet compounds with pKa values of 8.3 and higher resulted in approximately 20-26% removal. PMID:22934990

  7. Preparation of cyclodextrin-modified monolithic hybrid columns for the fast enantioseparation of hydroxy acids in capillary liquid chromatography.

    PubMed

    Szwed, Kamila; Ou, Junjie; Huang, Guang; Lin, Hui; Liu, Zhongshan; Wang, Hongwei; Zou, Hanfa

    2016-03-01

    Cyclodextrins and their derivatives are one of the most common and successful chiral selectors. However, there have been few publications about the use of cyclodextrin-modified monoliths. In this study, organic hybrid monoliths were prepared by the immobilization of derivatized β-cyclodextrin alone or with l-2-allylglycine hydrochloride to the polyhedral oligomeric silsesquioxane methacryl substituted monolith. The main topic of this study is a combined system with dual chiral selectors (l-2-allylglycine hydrochloride and β-cyclodextrin) as monolithic chiral stationary phase. The effect of l-2-allylglycine hydrochloride concentration on enantioseparation was investigated. The enantioseparation of the four acidic compounds with resolutions up to 2.87 was achieved within 2.5 min on the prepared chiral monolithic column in capillary liquid chromatography. Moreover, the possible mechanism of enantioseparation was discussed. PMID:27027591

  8. Reversed-phase liquid chromatography column testing: robustness study of the test.

    PubMed

    Le Mapihan, K; Vial, J; Jardy, A

    2004-12-24

    Choosing the right RPLC column for an actual separation among the more than 600 commercially available ones still represents a real challenge for the analyst particularly when basic solutes are involved. Many tests dedicated to the characterization and the classification of stationary phases have been proposed in the literature and some of them highlighted the need of a better understanding of retention properties to lead to a rational choice of columns. However, unlike classical chromatographic methods, the problem of their robustness evaluation has often been left unaddressed. In the present study, we present a robustness study that was applied to the chromatographic testing procedure we had developed and optimized previously. A design of experiment (DoE) approach was implemented. Four factors, previously identified as potentially influent, were selected and subjected to small controlled variations: solvent fraction, temperature, pH and buffer concentration. As our model comprised quadratic terms instead of a simple linear model, we chose a D-optimal design in order to minimize the experiment number. As a previous batch-to-batch study [K. Le Mapihan, Caractérisation et classification des phases stationnaires utilisées pour l'analyse CPL de produits pharmaceutiques, Ph.D. Thesis, Pierre and Marie Curie University, 2004] had shown a low variability on the selected stationary phase, it was then possible to split the design into two parts, according to the solvent nature, each using one column. Actually, our testing procedure involving assays both with methanol and with acetonitrile as organic modifier, such an approach enabled to avoid a possible bias due to the column ageing considering the number of experiments required (16 + 6 center points). Experimental results were computed thanks to a Partial Least Squares regression procedure, more adapted than the classical regression to handle factors and responses not completely independent. The results showed the

  9. Application of isothermal titration calorimetry and column chromatography for identification of biomolecular targets.

    PubMed

    Zhou, Xingding; Kini, R Manjunatha; Sivaraman, J

    2011-02-01

    This protocol describes a method for identifying unknown target proteins from a mixture of biomolecules for a given drug or a lead compound. This method is based on a combination of chromatography and isothermal titration calorimetry (ITC) where ITC is used as a tracking tool. The first step involves the use of ITC to confirm the binding of ligand to a component in the biomolecular mixture. Subsequently, the biomolecular mixture is fractionated by chromatography, and the binding of the ligand with individual fractions (or subfractions) is verified by ITC. The iteration of chromatographic purification on the fractions combined with ITC results in identifying the target protein. This method is useful when the target protein or ligand is unknown and/or not amenable to labeling, chemical modification or immobilization. This protocol has been successfully used by our team and by others to identify both low-abundance and highly abundant target proteins present in biomolecular mixtures. With this protocol, it takes approximately 3-5 d to identify the target protein from a mixture. PMID:21293457

  10. Residual on column host cell protein analysis during lifetime studies of protein A chromatography.

    PubMed

    Lintern, Katherine; Pathak, Mili; Smales, C Mark; Howland, Kevin; Rathore, Anurag; Bracewell, Daniel G

    2016-08-26

    Capacity reduction in protein A affinity chromatography with extended cycling during therapeutic antibody manufacture is well documented. Identification of which residual proteins remain from previous cycles during the lifetime of these adsorbent materials is required to understand their role in this ageing process, but represents a significant metrological challenge. Scanning electron microscopy (SEM) and liquid chromatography mass spectrometry (LC-MS/MS) are combined to detect and map this phenomenon of protein carry-over. We show that there is a morphological change at the surface of the agarose resin, revealing deposits on the polymer fibres increasing with cycle number. The amount of residual host cell proteins (HCPs) by LC-MS/MS present on the resin is shown to increase 10-fold between 50 and 100 cycles. During this same period the functional class of the predominant HCPs associated with the resin increased in diversity, with number of proteins identified increasing 5-fold. This ageing is observed in the context of the product quality of the eluate HCP and protein A leachate concentration remaining constant with cycle number. PMID:27473513

  11. Closed-loop optimization of chromatography column sizing strategies in biopharmaceutical manufacture

    PubMed Central

    Allmendinger, Richard; Simaria, Ana S; Turner, Richard; Farid, Suzanne S

    2014-01-01

    BACKGROUND This paper considers a real-world optimization problem involving the identification of cost-effective equipment sizing strategies for the sequence of chromatography steps employed to purify biopharmaceuticals. Tackling this problem requires solving a combinatorial optimization problem subject to multiple constraints, uncertain parameters, and time-consuming fitness evaluations. RESULTS An industrially-relevant case study is used to illustrate that evolutionary algorithms can identify chromatography sizing strategies with significant improvements in performance criteria related to process cost, time and product waste over the base case. The results demonstrate also that evolutionary algorithms perform best when infeasible solutions are repaired intelligently, the population size is set appropriately, and elitism is combined with a low number of Monte Carlo trials (needed to account for uncertainty). Adopting this setup turns out to be more important for scenarios where less time is available for the purification process. Finally, a data-visualization tool is employed to illustrate how user preferences can be accounted for when it comes to selecting a sizing strategy to be implemented in a real industrial setting. CONCLUSION This work demonstrates that closed-loop evolutionary optimization, when tuned properly and combined with a detailed manufacturing cost model, acts as a powerful decisional tool for the identification of cost-effective purification strategies. © 2013 The Authors. Journal of Chemical Technology & Biotechnology published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry. PMID:25506115

  12. Comparison of antioxidant and antiproliferative activity between Kunlun Chrysanthemum flowers polysaccharides (KCCP) and fraction PII separated by column chromatography.

    PubMed

    Jing, Siqun; Chai, Wenjie; Guo, Gai; Zhang, Xiaoming; Dai, Jun; Yan, Liang-Jun

    2016-04-15

    The aim of the present study was to compare the antioxidant and antiproliferative effects on cancer cells between Kunlun Chrysanthemum flowers polysaccharides (KCCP) and its fraction PII that were separated by Biologic low pressure (LP) chromatography system followed by DEAE cellulose column chromatography. Results of in vitro experiments showed that the reducing power and the scavenging capacity of KCCP towards hydroxyl radicals (OH) and 1,1-diphenyl-2-picrylhydrazyl (DPPH) radicals increased in a concentration dependent manner and were stronger than that of fraction PII. Results of the antiproliferative effect of KCCP and fraction PII on cervical cancer HeLa cells, esophagus cancer Eca109 cells, and mouse ascites hepatomas H22 cells indicated that both KCCP and its fraction PII possessed inhibitory activity on all the tested cancer cells at a dose- and time-dependent manner, with KCCP showing higher inhibitory activity than that of fraction PII. The present study demonstrates that KCCP and its fraction PII have antioxidant properties that may help fight cancers. PMID:26809376

  13. Kinetic performance of a 50mm long 1.8μm chiral column in supercritical fluid chromatography.

    PubMed

    Berger, Terry A

    2016-08-12

    Reduced plate heights (hr) of <2 were observed for the first time during the chiral separation of enantiomers, on sub-2μm particles with supercritical fluid chromatography (SFC). The enantiomers of trans-stilbene oxide, were separated on a 4.6×50mm, 1.8μm R,R-Whelk-O1 column, with hr as low as 1.93. The plumbing of a commercial SFC instrument was modified to create a low dispersion version. Without the modification performance was considerably worse. vanDeemter like plots of reduced plate height vs. flow rate, for trans-stilbene oxide, indicate that the optimum flow varied with% modifier. On a 4.6×250mm, 5μm R,R- Whelk-O1 column, the optimum flow was >4mL/min for 5% methanol in CO2, decreasing to <2mL/min for 40% methanol (more than a factor of 2). For a 4.6×50mm column packed with 1.8μm particles the optimum appeared to be near, or >5mL/min with 2.5%, 5%, and 10% methanol, decreasing to between 3 and 3.5mL/min at 40% methanol. This is the first time such shifts have been characterized. Since the solutes were the same in all cases, the differences are likely due to changes in solute diffusion coefficients caused by changes in modifier concentration, and pressure. Pump pressure requirements sometimes exceeded 500bar. It is shown that a 5mL/min flow rate is inadequate for use with 1.8μm particles in a 4.6mm ID column format. Instead, it is suggested to decrease the ID of the column to 3mm, where the optimum flow rates are on the order of 2mL/min with decreased tubing variance. Nevertheless, a number of sub-1min chromatograms are presented. PMID:27423775

  14. Detailed kinetic performance analysis of micromachined radially elongated pillar array columns for liquid chromatography.

    PubMed

    Callewaert, Manly; Desmet, Gert; Ottevaere, Heidi; De Malsche, Wim

    2016-02-12

    The individual factors that determine the kinetic performance (B- and C-term band broadening and bed permeability Kv) of radially elongated pillar (REP) columns are studied. To this end, columns with REPs having 4 different aspect ratios (AR=9, 12, 15, 20) were characterized experimentally and by means of numerical simulations. A tortuosity and retention based plate height equation was established, enabling a good global fit for all studied conditions. The B-term plate height contribution appears to decrease with a factor equaling the square of the flow path tortuosity τ. Going from AR=12 to AR=20 (τ=5.7 and τ=9.0 respectively), this resulted in a shift in plate height expressed in axial coordinates from Hmin=0.42 μm to Hmin=0.25 for non-retained conditions and from H=0.77 μm to H=0.57 μm for a component with k=1.0. The obtained parameters were combined to predict optimal time-efficiency combinations for all possible channel lengths. This revealed an efficiency limit of N=10(7) plates for a non-retained component and N=7-8 × 10(6) for k=1 for a channel with an AR=20, corresponding to a channel length of 2.5m and a void time of 2.4h. PMID:26795281

  15. Analysis of metal ions in crude oil by reversed-phase high performance liquid chromatography using short column.

    PubMed

    Salar Amoli, H; Porgam, A; Bashiri Sadr, Z; Mohanazadeh, F

    2006-06-16

    In this study a rapid, simultaneous analysis of V, Ni, Fe and Cu in crude oil was achieved by high performance liquid chromatography using 10 cm length reversed-phase C18 column. Since the amount of metal ions is at a very low level, in this work, solvent extraction of metals by a ligand such as 8-hydroxyquinoline from acidic media was investigated with some modification to previous procedures. Average extraction recoveries were 99, 85, 94 and 96 for V, Ni, Fe and Cu, respectively. The proposed method was successfully applied to the crude oil which was obtained from Koshk area in southern Iran. Fast analysis of metal ion in reversed-phase short column was achieved with methanol/water (55/45, v/v) and the detection limits measured as three times the background noise were obtained. Also it was shown that if small amount of 8-hydroxyquinoline was added to the mobile phase, the peak height and the peak symmetry were improved. A typical chromatogram for the separation of the 8-hydroxyquinoline complexes of V (V), Ni (II), Fe (III) and Cu (II) in crude oil was obtained in less than 4 min. PMID:16723133

  16. Packing of large-scale chromatography columns with irregularly shaped glass based resins using a stop-flow method

    PubMed Central

    Siu, Sun Chau; Chia, Celeste; Mok, Yanglin; Pattnaik, Priyabrata

    2014-01-01

    Rigid chromatography resins, such as controlled pore glass based adsorbents, offer the advantage of high permeability and a linear pressure-flow relationship irrespective of column diameter which improves process time and maximizes productivity. However, the rigidity and irregularly shaped nature of these resins often present challenges in achieving consistent and uniform packed beds as formation of bridges between resin particles can hinder bed consolidation. The standard flow-pack method when applied to irregularly shaped particles does not yield well-consolidated packed beds, resulting in formation of a head space and increased band broadening during operation. Vibration packing methods requiring the use of pneumatically driven vibrators are recommended to achieve full packed bed consolidation but limitations in manufacturing facilities and equipment may prevent the implementation of such devices. The stop-flow packing method was developed as an improvement over the flow-pack method to overcome these limitations and to improve bed consolidation without the use of vibrating devices. Transition analysis of large-scale columns packed using the stop-flow method over multiple cycles has shown a two- to three-fold reduction of change in bed integrity values as compared to a flow-packed bed demonstrating an improvement in packed bed stability in terms of the height equivalent to a theoretical plate (HETP) and peak asymmetry (As). PMID:25080096

  17. Packing of large-scale chromatography columns with irregularly shaped glass based resins using a stop-flow method.

    PubMed

    Siu, Sun Chau; Chia, Celeste; Mok, Yanglin; Pattnaik, Priyabrata

    2014-01-01

    Rigid chromatography resins, such as controlled pore glass based adsorbents, offer the advantage of high permeability and a linear pressure-flow relationship irrespective of column diameter which improves process time and maximizes productivity. However, the rigidity and irregularly shaped nature of these resins often present challenges in achieving consistent and uniform packed beds as formation of bridges between resin particles can hinder bed consolidation. The standard flow-pack method when applied to irregularly shaped particles does not yield well-consolidated packed beds, resulting in formation of a head space and increased band broadening during operation. Vibration packing methods requiring the use of pneumatically driven vibrators are recommended to achieve full packed bed consolidation but limitations in manufacturing facilities and equipment may prevent the implementation of such devices. The stop-flow packing method was developed as an improvement over the flow-pack method to overcome these limitations and to improve bed consolidation without the use of vibrating devices. Transition analysis of large-scale columns packed using the stop-flow method over multiple cycles has shown a two- to three-fold reduction of change in bed integrity values as compared to a flow-packed bed demonstrating an improvement in packed bed stability in terms of the height equivalent to a theoretical plate (HETP) and peak asymmetry (As ). PMID:25080096

  18. Rapid quantitative enrichment of carnosic acid from rosemary (Rosmarinus officinalis L.) by isoelectric focused adsorptive bubble chromatography.

    PubMed

    Backleh, Marlène; Leupold, Günther; Parlar, Harun

    2003-02-26

    For the first time, the potent but unstable antioxidative diterpene carnosic acid could be enriched from an aqueous extract of rosemary (Rosmarinus officinalis L.) by isoelectric focused adsorptive bubble chromatography. Enrichment of carnosic acid in the foam was influenced by the pH value and the flow rate of the foam-forming gas. Efficiency was highest with diluted samples at pH 4. Under these conditions, the conversion of carnosic acid to carnosol was negligible. Transfer of carnosic acid to the foam from a standard solution in the presence of saponin as surfactive substance was similar to that from the aqueous rosemary extract. PMID:12590472

  19. [Determination of 14 sulfonamide residues in shrimps by high performance liquid chromatography coupled with post-column derivatization].

    PubMed

    Huang, Dongmei; Huang, Xuanyun; Gu, Runrun; Hui, Yunhua; Tian, Liangliang; Feng, Bing; Zhang, Xuan; Yu, Huijuan

    2014-08-01

    A method for the determination of 14 sulfonamide residues in shrimps by high performance liquid chromatography coupled with post-column derivatization was established. The sulfonamide residues were extracted with ethyl acetate after adding sulfapyridine as internal standard. The extracts were vacuum-concentrated and reverse-extracted by 2 mol/L hydrochloric acid solution for clean-up, and then the hydrochloric acid solution was defatted with n-hex- ane. The solution after filtration was blended with a mixed solution of methanol, acetonitrile and 3. 5 mol/L sodium acetate solution (5:5:20, v/v/v). The sulfonamides were separated on a C18 column by RP-HPLC and on-line derivatized with a fluorescamine and detected with a fluorescence detector. The standard addition method was used for quantitative analysis. The parameters of post-column derivatization system, such as concentration of fluorescamine solution, velocity of reagent solution and reaction temperature, were optimized. The calibration curves of the method showed good linearity in the range of 5 - 200 μg/L. The limits of quantification (LOQ, S/N= 10) were 1.0-5.0 μg/kg for the 14 sulfonamides. The recoveries were 77.8%- 103. 6% in the spiked range of 1. 0-100.0 μg/kg in shrimps with the relative standard deviations of 2.9%-9.1% (n= 6). The results indicated that the method is sensitive, efficient and more accurate. It is suitable for the simultaneous determination of the 14 sulfonamide residues in shrimps. PMID:25434125

  20. Immunoaffinity column cleanup with liquid chromatography for determination of aflatoxin B1 in corn samples: interlaboratory study.

    PubMed

    Brera, Carlo; Debegnach, Francesca; Minardi, Valentina; Pannunzi, Elena; De Santis, Barbara; Miraglia, Marina

    2007-01-01

    An interlaboratory study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for the determination of aflatoxin B1 levels in corn samples, enforced by European Union legislation. A test portion was extracted with methanol-water (80 + 20); the extract was filtered, diluted with phosphate-buffered saline solution, filtered on a microfiber glass filter, and applied to an immunoaffinity column. The column was washed with deionized water to remove interfering compounds, and the purified aflatoxin B1 was eluted with methanol. Aflatoxin B1 was separated and determined by reversed-phase LC with fluorescence detection after either pre- or postcolumn derivatization. Precolumn derivatization was achieved by generating the trifluoroacetic acid derivative, used by 8 laboratories. The postcolumn derivatization was achieved either with pyridinium hydrobromide perbromide, used by 16 laboratories, or with an electrochemical cell by the addition of bromide to the mobile phase, used by 5 laboratories. The derivatization techniques used were not significantly different when compared by the Student's t-test; the method was statistically evaluated for all the laboratories. Five corn sample materials, both spiked and naturally contaminated, were sent to 29 laboratories (22 Italian and 7 European). Test portions were spiked with aflatoxin B1 at levels of 2.00 and 5.00 ng/g. The mean values for recovery were 82% for the low level and 84% for the high contamination level. Based on results for spiked samples (blind pairs at 2 levels) as well as naturally contaminated samples (blind pairs at 3 levels), the values for relative standard deviation for repeatability (RSDr) ranged from 9.9 to 28.7%. The values for relative standard deviation for reproducibility (RSDR) ranged from 18.6 to 36.8%. The method demonstrated acceptable within- and between-laboratory precision for this matrix, as evidenced by the HorRat values. PMID:17580628

  1. Determination of sulfathiazole in type C medicated swine feed by reversed-phase liquid chromatography with post-column derivatization.

    PubMed

    Albert, Kendrick; Riter, Ken L; Smallidge, Robert L

    2003-01-01

    A convenient method was developed for determination of sulfathiazole (STZ) in Type C medicated swine feed by reversed-phase liquid chromatography (LC) with post-column derivatization. Addition of extractant solution (0.2N HCl and 1.5% diethylamine in 25% methanol) and an internal standard (IS), sulfamethylthiazole (SMZ), to 5 g sample was followed by mechanical shaking for 1 h. The extract was clarified by chilling, centrifugation, and filtering before injection onto a C18 reversed-phase column. The mobile phase components were 2% acetic acid and 1:1 acetonitrile-methanol (83 + 17%, v/v). Run time was about 20 min. Determination and, largely, the method's selectivity were based on detection at 450 nm of the derivative formed by the post-column reaction of dimethylaminobenzaldehyde with the primary amine of the analyte and IS. The IS, SMZ, differs from STZ by a single substituent methyl group, is stable, and is readily resolved from STZ. Although SMZ is not commercially available, it can be synthesized with relative ease from purchased reagents and will be supplied by the authors to interested laboratories. In single-laboratory validation, linearity was demonstrated over the range of 0.055-550 microg/mL, well beyond the target concentration of 5.5 microg/mL. The estimated limit of detection was 0.04 microg/mL; the calculated limit of quantitation was 0.13 microg/mL (feed concentration of 2.4 g/T or 2.7 mg/kg). Wet-spiking trials with a variety of swine feed matrixes showed recovery to be 100-102% for the intended concentration range, 50-200 g/T, with coefficient of variation (CV) < 2%. The method ruggedness was verified with an overall CV of 2.9%. PMID:14509417

  2. Balancing Size Exclusion and Adsorption of Methacrylate Polymers in Nanoporous Silica

    NASA Astrophysics Data System (ADS)

    Abdulahad, Asem; Lee, Sekyung; Chang, Taihyun; Ryu, Chang

    2010-03-01

    Liquid chromatography at the critical condition (LCCC) is a high performance liquid chromatography (HPLC) technique that lies between size exclusion chromatography (SEC) and adsorption-based interaction chromatography (IC) where the elution of polymers becomes independent of polymer molecular weight. At LCCC, the balance between the entropic exclusion and the enthalpic adsorption interactions between polymers and stationary phases results in the simultaneous elution of polymers regardless of molecular weight. Using C18-bonded silica chromatographic columns we demonstrate the LCCC elution of a series of methacrylate polymers and discuss how the alkyl side groups in methacrylate polymers affects the adsorption of polymer chains against the size exclusion in nanopores.

  3. A hybrid fluorous monolithic capillary column with integrated nanoelectrospray ionization emitter for determination of perfluoroalkyl acids by nano-liquid chromatography-nanoelectrospray ionization-mass spectrometry/mass spectrometry.

    PubMed

    Zhang, Haiyang; Ou, Junjie; Wei, Yinmao; Wang, Hongwei; Liu, Zhongshan; Zou, Hanfa

    2016-04-01

    A hybrid fluorous monolithic column was simply prepared via photo-initiated free radical polymerization of an acrylopropyl polyhedral oligomeric silsesquioxane (acryl-POSS) and a perfluorous monomer (2,2,3,3,4,4,5,5,6,6,7,7-dodecafluoroheptyl acrylate) in UV-transparent fused-silica capillaries within 5min. The physical characterization of hybrid fluorous monolith, including scanning electron microscopy (SEM), Fourier transform infrared (FT-IR) spectroscopy, mercury intrusion porosimetry (MIP) and nitrogen adsorption/desorption measurement was performed. Chromatographic performance was also evaluated by capillary liquid chromatography (cLC). Due to the fluorous-fluorous interaction between fluorous monolith and analytes, fluorobenzenes could well be separated, and the column efficiencies reached 86,600-92,500plates/m at the velocity of 0.87mm/s for alkylbenzenes and 51,900-76,000plates/m at the velocity of 1.10mm/s for fluorobenzenes. Meanwhile, an approach to integrate nanoelectrospray ionization (ESI) emitter with hybrid fluorous monolithic column was developed for quantitative determination of perfluoroalkyl acids by nanoHPLC-ESI-MS/MS. The integration design could minimize extracolumn volume, thus excluding undesirable peak broadening and improving separation performance. PMID:26916593

  4. Chromatography

    MedlinePlus

    Chromatography is a way of separating two or more chemical compounds. Chemical compounds are chemicals that are ... of chemical compound. There are different kinds of chromatography. These include gas, high pressure liquid, or ion ...

  5. Separation of the Components of a Commercial Analgesic Tablet: A Two-Week Sequence Comparing Purification by Two-Base Extraction and Column Chromatography

    ERIC Educational Resources Information Center

    Revell, Kevin D.

    2011-01-01

    A new laboratory experiment is described in which students compare two benchtop separation methods to isolate the three active components of the commercial analgesic Excedrin. In the two-week sequence, aspirin, acetaminophen, and caffeine are separated using either a two-base liquid-liquid extraction or silica column chromatography. Students then…

  6. Determination of citrus limonoid glucosides by high performance liquid chromatography coupled to post-column reaction with Ehrlich’s Reagent

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A method for the identification and quantification of citrus limonoid glucosides in juices based upon high performance liquid chromatography (HPLC) separation coupled to post-column reaction with Ehrlichs’s reagent has been developed. This method utilizes a phenyl stationary phase and an isocratic ...

  7. The Trace Analysis of DEET in Water using an On-line Preconcentration Column and Liquid Chromatography with UV Photodiode Array Detection

    EPA Science Inventory

    A method for the detection of trace levels of N,N-diethyl-m-toluamide (DEET) in water is discussed. The method utilizes an on-line preconcentration column in series with high performance liquid chromatography (HPLC) and UV photodiode array detection. DEET, a common insect repel...

  8. Characterization of a Multiple Ligand-Gated Ion Channel Cellular Membrane Affinity Chromatography Column and Identification of Endogenously Expressed Receptors in Astrocytoma Cell Lines

    PubMed Central

    Kitabatake, T.; Moaddel, R.; Cole, R.; Gandhari, M.; Frazier, C.; Hartenstein, J.; Rosenberg, A.; Bernier, M.; Wainer, I. W.

    2008-01-01

    Cellular membranes obtained from the 1321N1 and A172 astrocytoma cell lines were immobilized on a chromatographic phase to create cellular membrane affinity chromatography (CMAC) columns, CMAC(1321N1) and CMAC(A172). The columns were characterized using frontal affinity chromatography with [3H]-epibatidine as the marker ligand and epibatidine, nicotine, and methyllycaconitine as the displacers. The results indicated that the columns contained homomeric α7 nicotinic acetylcholine receptors (α7 nAChR) and heteromeric nicotinic acetylcholine receptors (αxβy nAChRs), which was confirmed by the addition of subtype-specific inhibitors, κ-bungarotoxin (α7 nAChR) and K-bungarotoxin (αxβy nAChR) to the mobile phase. The presence of two additional ligand-gated ion channels (LGICs), γ-aminobutyric acid (GABAA) and N-methyl-d-aspartic acid (NMDA), was established using frontal affinity chromatography with flunitrazepam and diazepam (GABAA receptor) and MK-801 and NMDA (NMDA receptor). The presence of the four LGICs was confirmed using confocal microscopy and flow cytometry. The results indicate that the CMAC(1321N1) and CMAC(A172) columns contain four independently functioning LGICs, that the columns can be used to characterize binding affinities of small molecules to each of the receptors, and that the CMAC approach can be used to probe the expression of endogenous membrane receptors. PMID:18847217

  9. Characterization of a multiple ligand-gated ion channel cellular membrane affinity chromatography column and identification of endogenously expressed receptors in astrocytoma cell lines.

    PubMed

    Kitabatake, T; Moaddel, R; Cole, R; Gandhari, M; Frazier, C; Hartenstein, J; Rosenberg, A; Bernier, M; Wainer, I W

    2008-11-15

    Cellular membranes obtained from the 1321N1 and A172 astrocytoma cell lines were immobilized on a chromatographic phase to create cellular membrane affinity chromatography (CMAC) columns, CMAC(1321N1) and CMAC(A172). The columns were characterized using frontal affinity chromatography with [(3)H]-epibatidine as the marker ligand and epibatidine, nicotine, and methyllycaconitine as the displacers. The results indicated that the columns contained homomeric alpha7 nicotinic acetylcholine receptors (alpha7 nAChR) and heteromeric nicotinic acetylcholine receptors (alpha(x)beta(y) nAChRs), which was confirmed by the addition of subtype-specific inhibitors, alpha-bungarotoxin (alpha7 nAChR) and kappa-bungarotoxin (alpha(x)beta(y) nAChR) to the mobile phase. The presence of two additional ligand-gated ion channels (LGICs), gamma-aminobutyric acid (GABA(A)) and N-methyl-D-aspartic acid (NMDA), was established using frontal affinity chromatography with flunitrazepam and diazepam (GABA(A) receptor) and MK-801 and NMDA (NMDA receptor). The presence of the four LGICs was confirmed using confocal microscopy and flow cytometry. The results indicate that the CMAC(1321N1) and CMAC(A172) columns contain four independently functioning LGICs, that the columns can be used to characterize binding affinities of small molecules to each of the receptors, and that the CMAC approach can be used to probe the expression of endogenous membrane receptors. PMID:18847217

  10. Synthesis and characterization of a SIRT6 open tubular column: predicting deacetylation activity using frontal chromatography.

    PubMed

    Singh, Nagendra; Ravichandran, Sarangan; Norton, Darrell D; Fugmann, Sebastian D; Moaddel, Ruin

    2013-05-15

    SIRT6 is a histone deacetylase that has been proposed as a potential therapeutic target for metabolic disorders and the prevention of age-associated diseases. Thus the identification of compounds that modulate SIRT6 activity could be of great therapeutic importance. We have previously reported on the identification of quercetin and vitexin as SIRT6 inhibitors, using SIRT6-coated magnetic beads. In this study, we have immobilized SIRT6 onto the surface of an open tubular capillary and characterized the quercetin binding site using frontal displacement chromatography. Structurally related flavonoids were tested for their activity on SIRT6, including apigenin, naringenin, luteolin, and kaempferol. In addition to obtaining their binding activity using frontal affinity chromatographic techniques, we also ranked the compounds based on their ability to displace quercetin. The data suggest that a single displacement curve is representative of the enzymatic activity of the tested ligand. In addition, using the inhibition data obtained in this study, we developed a preliminary pharmacophore model that confirmed the experimental data. PMID:23376017

  11. Synthesis and Characterization of a SIRT6 Open Tubular Column: Predicting Deacetylation Activity using Frontal Chromatography

    PubMed Central

    Singh, Nagendra; Ravichandran, Sarangan; Norton, Darrell D.; Fugmann, Sebastian D.; Moaddel, Ruin

    2014-01-01

    SIRT6 is a histone deacetylase that has been proposed as a potential therapeutic target for metabolic disorders and the prevention of age-associated diseases. Thus the identification of compounds that modulate SIRT6 activity could be of great therapeutic importance. We have previously reported on the identification of quercetin and vitexin as SIRT6 inhibitors, using SIRT6-coated magnetic beads. In this study, we have immobilized SIRT6 onto the surface of an open tubular capillary and characterized the quercetin binding site using frontal displacement chromatography. Structurally related flavonoids were tested for their activity on SIRT6, including apigenin, naringenin, luteolin and kaempferol. In addition to obtaining their binding activity using frontal affinity chromatographic techniques, we also ranked the compounds based on their ability to displace quercetin. The data suggest that a single displacement curve is representative of the enzymatic activity of the tested ligand. In addition, using the inhibition data obtained in this study, we developed a preliminary pharmacophore model that confirmed the experimental data. PMID:23376017

  12. Application of gas-liquid chromatography to the analysis of essential oils. Part XVII. Fingerprinting of essential oils by temperature-programmed gas-liquid chromatography using capillary columns with non-polar stationary phases. Analytical methods committee.

    PubMed

    1997-10-01

    Problems in obtaining reproducible results when 'fingerprinting' essential oils by temperature-programmed gas-liquid chromatography have been reported on in Parts VII and VIII of this series. Those reports were concerned with the general problems and the use of packed columns. This report is concerned with the use of capillary columns and non-polar stationary phases. A collaborative study using capillary columns with non-polar stationary phases has resulted in a method which specifies the 'g-pack value' of a column and gives reproducible relative retention indices for the test compounds limonene, acetophenone, linalol, naphthalene, linalyl acetate and cinnamyl alcohol. The method has been applied successfully to the examination of oil of rosemary. A recommended method is given for the reproducible temperature-programmed gas-liquid chromatographic fingerprinting of essential oils using capillary columns with non-polar stationary phases. PMID:9463975

  13. Solid-phase microextraction/gas chromatography-mass spectrometry method optimization for characterization of surface adsorption forces of nanoparticles.

    PubMed

    Omanovic-Miklicanin, Enisa; Valzacchi, Sandro; Simoneau, Catherine; Gilliland, Douglas; Rossi, Francois

    2014-10-01

    A complete characterization of the different physico-chemical properties of nanoparticles (NPs) is necessary for the evaluation of their impact on health and environment. Among these properties, the surface characterization of the nanomaterial is the least developed and in many cases limited to the measurement of surface composition and zetapotential. The biological surface adsorption index approach (BSAI) for characterization of surface adsorption properties of NPs has recently been introduced (Xia et al. Nat Nanotechnol 5:671-675, 2010; Xia et al. ACS Nano 5(11):9074-9081, 2011). The BSAI approach offers in principle the possibility to characterize the different interaction forces exerted between a NP's surface and an organic--and by extension biological--entity. The present work further develops the BSAI approach and optimizes a solid-phase microextraction gas chromatography-mass spectrometry (SPME/GC-MS) method which, as an outcome, gives a better-defined quantification of the adsorption properties on NPs. We investigated the various aspects of the SPME/GC-MS method, including kinetics of adsorption of probe compounds on SPME fiber, kinetic of adsorption of probe compounds on NP's surface, and optimization of NP's concentration. The optimized conditions were then tested on 33 probe compounds and on Au NPs (15 nm) and SiO2 NPs (50 nm). The procedure allowed the identification of three compounds adsorbed by silica NPs and nine compounds by Au NPs, with equilibrium times which varied between 30 min and 12 h. Adsorption coefficients of 4.66 ± 0.23 and 4.44 ± 0.26 were calculated for 1-methylnaphtalene and biphenyl, compared to literature values of 4.89 and 5.18, respectively. The results demonstrated that the detailed optimization of the SPME/GC-MS method under various conditions is a critical factor and a prerequisite to the application of the BSAI approach as a tool to characterize surface adsorption properties of NPs and therefore to draw any further

  14. Application of ultra-performance columns in high-performance liquid chromatography for determination of albendazole and its metabolites in turkeys.

    PubMed

    Grabowski, Tomasz; Jaroszewski, Jerzy Jan; Swierczewska, Anna; Sawicka, Renata; Maślanka, Tomasz; Markiewicz, Włodzimierz; Ziółkowski, Hubert

    2011-10-01

    Methods for determination of albendazole (ALB), albendazole sulfoxide (SOX) and albendazole sulfone (SON) in turkey blood plasma, using high-performance liquid chromatography (HPLC) with fluorescence detection, were developed. Moreover, comparison of HPLC columns with ultra-performance liquid chromatography (UPLC) columns was performed. Albendazol was administered orally in 5-week-old birds (n = 18) at a dose of 25 mg/kg b.w. Accuracy and precision of the developed method were satisfactory and stability studies showed acceptable variation (below 15%) in ALB, SOX and SON concentrations when the samples were stored at -75°C for 15 days. UPLC(®) columns gave higher peaks from typical HPLC columns retaining high quality of analysis. Pharmacokinetic analysis indicated quick elimination of ALB from turkey blood plasma. The mean residence time of SON was at least two times longer than that of SOX and four times longer than that of ALB. The elimination half-lives for ALB, SOX and SON were 0.7 ± 0.27, 5.37 ± 6.03, 9.17 ± 5.12 h, respectively. The obtained results indicate that the described method allows for precise determination of albendazole and its metabolites in turkey plasma. Moreover, using UPLC columns in HPLC apparatus results in higher sensitivity as compared with the classical HPLC columns. PMID:21294142

  15. Scale-up protein separation on stainless steel wide bore toroidal columns in the type-J counter-current chromatography.

    PubMed

    Guan, Yue Hugh; Hewitson, Peter; van den Heuvel, Remco N A M; Zhao, Yan; Siebers, Rick P G; Zhuang, Ying-Ping; Sutherland, Ian

    2015-12-11

    Manufacturing high-value added biotech biopharmaceutical products (e.g. therapeutic proteins) requires quick-to-develop, GMP-compliant, easy-to-scale and cost effective preparatory chromatography technologies. In this work, we describe the construction and testing of a set of 5-mm inner diameter stainless steel toroidal columns for use on commercially available preparatory scale synchronous J-type counter-current chromatography (CCC) machinery. We used a 20.2m long column with an aqueous two-phase system containing 14% (w/w) PEG1000 and 14% (w/w) potassium phosphate at pH 7, and tested a sample loading of 5% column volume and a mobile phase flow rate of 20ml/min. We then satisfactorily demonstrated the potential for a weekly protein separation and preparation throughput of ca. 11g based on a normal weekly routine for separating a pair of model proteins by making five stacked injections on a single portion of stationary phase with no stripping. Compared to our previous 1.6mm bore PTFE toroidal column, the present columns enlarged the nominal column processing throughput by nearly 10. For an ideal model protein injection modality, we observed a scaling up factor of at least 21. The 2 scales of protein separation and purification steps were realized on the same commercial CCC device. PMID:25818556

  16. Integrated system for temperature-controlled fast protein liquid chromatography. II. Optimized adsorbents and 'single column continuous operation'.

    PubMed

    Cao, Ping; Müller, Tobias K H; Ketterer, Benedikt; Ewert, Stephanie; Theodosiou, Eirini; Thomas, Owen R T; Franzreb, Matthias

    2015-07-17

    Continued advance of a new temperature-controlled chromatography system, comprising a column filled with thermoresponsive stationary phase and a travelling cooling zone reactor (TCZR), is described. Nine copolymer grafted thermoresponsive cation exchangers (thermoCEX) with different balances of thermoresponsive (N-isopropylacrylamide), hydrophobic (N-tert-butylacrylamide) and negatively charged (acrylic acid) units were fashioned from three cross-linked agarose media differing in particle size and pore dimensions. Marked differences in grafted copolymer composition on finished supports were sourced to base matrix hydrophobicity. In batch binding tests with lactoferrin, maximum binding capacity (qmax) increased strongly as a function of charge introduced, but became increasingly independent of temperature, as the ability of the tethered copolymer networks to switch between extended and collapsed states was lost. ThermoCEX formed from Sepharose CL-6B (A2), Superose 6 Prep Grade (B2) and Superose 12 Prep Grade (C1) under identical conditions displayed the best combination of thermoresponsiveness (qmax,50°C/qmax,10°C ratios of 3.3, 2.2 and 2.8 for supports 'A2', 'B2' and 'C1' respectively) and lactoferrin binding capacity (qmax,50°C∼56, 29 and 45mg/g for supports 'A2', 'B2' and 'C1' respectively), and were selected for TCZR chromatography. With the cooling zone in its parked position, thermoCEX filled columns were saturated with lactoferrin at a binding temperature of 35°C, washed with equilibration buffer, before initiating the first of 8 or 12 consecutive movements of the cooling zone along the column at 0.1mm/s. A reduction in particle diameter (A2→B2) enhanced lactoferrin desorption, while one in pore diameter (B2→C1) had the opposite effect. In subsequent TCZR experiments conducted with thermoCEX 'B2' columns continuously fed with lactoferrin or 'lactoferrin+bovine serum albumin' whilst simultaneously moving the cooling zone, lactoferrin was

  17. Coupling isotachophoresis with affinity chromatography for rapid and selective purification with high column utilization, part 2: experimental study.

    PubMed

    Shkolnikov, Viktor; Santiago, Juan G

    2014-07-01

    We present an experimental study of coupling of isotachophoresis (ITP) and affinity chromatography (AC) to effect rapid, selective purification with high column utilization and high resolution. We provide a detailed protocol for performing ITP-AC and describe the design of a buffer system to perform sequence specific separation of nucleic acids. We describe the synthesis and functionalization of our affinity substrate, poly(glycidyl methacrylate-co-ethylene dimethacrylate) porous polymer monolith (GMA-EDMA PPM). This substrate allows easy immobilization of affinity probes, is nonsieving (even to macromolecules), and exhibits negligible nonspecific binding. We demonstrate ITP-AC with 25 nt, Cy5 labeled DNA target and a DNA probe and study the spatiotemporal dynamics using epifluorescence imaging. We make qualitative and quantitative comparisons between these data and the model presented in the first part of this two-paper series. We vary the target concentration from 1 pg μL(-1) to 100 pg μL(-1) and ITP velocity over the range of 10-50 μm s(-1), and thereby explore over 4 orders of magnitude of scaled target amount. We observe very good agreement between predictions and experimental data for the spatiotemporal behavior of the coupled ITP and affinity process, and for key figures of merit, including scaled capture length and maximum capture efficiency. Lastly, we demonstrate that the resolution of ITP-AC increases linearly with time and purify 25 nt target DNA from 10,000-fold higher abundance background (contaminating) genomic fish sperm DNA. We perform this capture from 200 μL of sample in under 1 mm column length and within <10 min. PMID:24937777

  18. [Determination of free formaldehyde in cosmetics by pre-column derivatization, extraction inhibition and high performance liquid chromatography].

    PubMed

    Lü, Chunhua; Huang, Chaoqun; Chen, Mei; Xie, Wen; Chen, Xiaomei

    2012-12-01

    Pre-column derivatization and inhibition by solvent extraction were applied to determine free formaldehyde in cosmetics by high performance liquid chromatography (HPLC). Due to the rapid decomposition of formaldehyde donors in the derivatization, it is hard to detect the amount of the free formaldehyde in cosmetics. The formaldehyde directly reacted with 2,4-dinitrophenylhydrazine in acetonitrile-phosphate buffer (pH 2) (1:1, v/v) solution for 2 min, then dichloromethane extraction was used to induce the decomposition of formaldehyde donors. The extract was diluted with acetonitrile and then determined by HPLC. The formaldehyde derivative was separated on an Agilent C18 column (250 mm x 4.6 mm, 5 microm) at 30 degrees C with acetonitrile-water (60:40, v/v) as mobile phase at a flow rate of 1.0 mL/min, and detected at the wavelength of 355 nm. The recoveries were from 81% to 106% at the spiked levels of 50, 100, 500, 1 000 microg/g of formaldehyde in shampoo, milk, cream, hand cleaner, toothpaste, nail polish, powder separately, and the relative standard deviations (n = 6) were less than 5.0%. The limit of quantification of the formaldehyde in cosmetics was 50 microg/g. The method has been applied to the determination of free formaldehyde in real samples and the results showed that the release by formaldehyde donors was inhibited. The method has the advantages of simple operation, good accuracy and meets the requirement of determination of free formaldehyde in cosmetics. PMID:23593888

  19. Coupling Isotachophoresis with Affinity Chromatography for Rapid and Selective Purification with High Column Utilization, Part 2: Experimental Study

    PubMed Central

    2015-01-01

    We present an experimental study of coupling of isotachophoresis (ITP) and affinity chromatography (AC) to effect rapid, selective purification with high column utilization and high resolution. We provide a detailed protocol for performing ITP-AC and describe the design of a buffer system to perform sequence specific separation of nucleic acids. We describe the synthesis and functionalization of our affinity substrate, poly(glycidyl methacrylate-co-ethylene dimethacrylate) porous polymer monolith (GMA-EDMA PPM). This substrate allows easy immobilization of affinity probes, is nonsieving (even to macromolecules), and exhibits negligible nonspecific binding. We demonstrate ITP-AC with 25 nt, Cy5 labeled DNA target and a DNA probe and study the spatiotemporal dynamics using epifluorescence imaging. We make qualitative and quantitative comparisons between these data and the model presented in the first part of this two-paper series. We vary the target concentration from 1 pg μL–1 to 100 pg μL–1 and ITP velocity over the range of 10–50 μm s–1, and thereby explore over 4 orders of magnitude of scaled target amount. We observe very good agreement between predictions and experimental data for the spatiotemporal behavior of the coupled ITP and affinity process, and for key figures of merit, including scaled capture length and maximum capture efficiency. Lastly, we demonstrate that the resolution of ITP-AC increases linearly with time and purify 25 nt target DNA from 10 000-fold higher abundance background (contaminating) genomic fish sperm DNA. We perform this capture from 200 μL of sample in under 1 mm column length and within <10 min. PMID:24937777

  20. Quantitation of triacylglycerols in edible oils by off-line comprehensive two-dimensional liquid chromatography-atmospheric pressure chemical ionization mass spectrometry using a single column.

    PubMed

    Wei, Fang; Hu, Na; Lv, Xin; Dong, Xu-Yan; Chen, Hong

    2015-07-24

    In this investigation, off-line comprehensive two-dimensional liquid chromatography-atmospheric pressure chemical ionization mass spectrometry using a single column has been applied for the identification and quantification of triacylglycerols in edible oils. A novel mixed-mode phenyl-hexyl chromatographic column was employed in this off-line two-dimensional separation system. The phenyl-hexyl column combined the features of traditional C18 and silver-ion columns, which could provide hydrophobic interactions with triacylglycerols under acetonitrile conditions and can offer π-π interactions with triacylglycerols under methanol conditions. When compared with traditional off-line comprehensive two-dimensional liquid chromatography employing two different chromatographic columns (C18 and silver-ion column) and using elution solvents comprised of two phases (reversed-phase/normal-phase) for triacylglycerols separation, the novel off-line comprehensive two-dimensional liquid chromatography using a single column can be achieved by simply altering the mobile phase between acetonitrile and methanol, which exhibited a much higher selectivity for the separation of triacylglycerols with great efficiency and rapid speed. In addition, an approach based on the use of response factor with atmospheric pressure chemical ionization mass spectrometry has been developed for triacylglycerols quantification. Due to the differences between saturated and unsaturated acyl chains, the use of response factors significantly improves the quantitation of triacylglycerols. This two-dimensional liquid chromatography-mass spectrometry system was successfully applied for the profiling of triacylglycerols in soybean oils, peanut oils and lord oils. A total of 68 triacylglycerols including 40 triacylglycerols in soybean oils, 50 triacylglycerols in peanut oils and 44 triacylglycerols in lord oils have been identified and quantified. The liquid chromatography-mass spectrometry data were analyzed

  1. Gas Chromatography.

    ERIC Educational Resources Information Center

    Karasek, Francis W.; And Others

    1984-01-01

    This review covers fundamental developments in gas chromatography during 1982 and 1983. Literature is considered under these headings: columns; liguid phases; solid supports; sorption processes and solvents; open tubular column gas chromatography; instrumentation; high-resolution columns and applications; other techniques; qualitative and…

  2. Effect of pressure pulses at the interface valve on the stability of second dimension columns in online comprehensive two-dimensional liquid chromatography.

    PubMed

    Talus, Eric S; Witt, Klaus E; Stoll, Dwight R

    2015-01-23

    Users of online comprehensive two-dimensional liquid chromatography (LCxLC) frequently acknowledge that the mechanical instability of HPLC columns installed in these systems, particularly in the second dimension, is a significant impediment to its use. Such instability is not surprising given the strenuous operating environment to which these columns are subjected, including the large number (thousands per day) of fast and large pressure pulses resulting from interface valve switches (on the timescale of tens of milliseconds) associated with very fast second dimension separations. There appear to be no published reports of systematic studies of the relationship between second dimension column lifetime and any of these variables. In this study we focused on the relationship between the lifetimes of commercially available columns and the pressure pulses observed at the inlet of the second dimension column that occur during the switching of the valve that interfaces the two dimensions of a LCxLC system. We find that the magnitude of the pressure drop at the inlet of the second dimension column during the valve switch, which may vary between 10 and 95% of the column inlet pressure, is dependent on valve switching speed and design, and has a dramatic impact on column lifetime. In the worst case, columns fail within the first few hours of use in an LCxLC system. In the best case, using a valve that exhibits much smaller pressure pulses, the same columns exhibit much improved lifetimes and have been used continuously under LCxLC conditions for several days with no degradation in performance. This result represents a first step in understanding the factors that affect second dimension column lifetime, and will significantly improve the usability of the LCxLC technique in general. PMID:25553909

  3. Implementation of high slurry concentration and sonication to pack high-efficiency, meter-long capillary ultrahigh pressure liquid chromatography columns.

    PubMed

    Godinho, Justin M; Reising, Arved E; Tallarek, Ulrich; Jorgenson, James W

    2016-09-01

    Slurry packing capillary columns for ultrahigh pressure liquid chromatography is complicated by many interdependent experimental variables. Previous results have suggested that combination of high slurry concentration and sonication during packing would create homogeneous bed microstructures and yield highly efficient capillary columns. Herein, the effect of sonication while packing very high slurry concentrations is presented. A series of six, 1m×75μm internal diameter columns were packed with 200mg/mL slurries of 2.02μm bridged-ethyl hybrid silica particles. Three of the columns underwent sonication during packing and yielded highly efficient separations with reduced plate heights as low as 1.05. PMID:27499108

  4. Tracing novel hemostatic compounds from heating products of total flavonoids in Flos Sophorae by spectrum-effect relationships and column chromatography.

    PubMed

    Chen, Yeqing; Yu, Hongli; Wu, Hao; Pan, Yaozong; Wang, Kuilong; Liu, Liping; Jin, Yangping; Zhang, Chenchao

    2015-05-01

    Flos Sophorae and its processed product have been clinically used to treat hemorrhage. In this study, the total ion chromatographic fingerprints of the heating products of total flavonoids in Flos Sophorae were established by high-performance liquid chromatography with tandem mass spectrometry and the hemostatic activities were studied by hemostatic screening tests in vivo. The spectrum-effect relationships between fingerprints and hemostatic activities were investigated using canonical correlation analysis to trace the peaks responsible for the hemostatic effects. The predicted active peaks in fingerprints were isolated by column chromatography and their structures were identified by NMR spectroscopy and mass spectrometry. The hemostatic activities of them were verified by platelet aggregation and procoagulation assays in vitro. Canonical correlation analysis results showed that peak 8 and peak 11 were correlated most closely, thus probably being the main hemostatic compounds. Through column chromatography separation, peak 8 (compound I) and peak 11 (compound II) were obtained with purities of 95.61 and 93.38%, respectively, and were discovered new hemostatic compounds named as huaicarbon A (I) and huaicarbon B (II), respectively. This study provides a universal model to trace the active compounds of other herbs which have bioactivity enhancement after processing by spectrum-effect relationships and column chromatography. PMID:25764522

  5. Separation and purification of phosphatidylcholine and phosphatidylethanolamine from soybean degummed oil residues by using solvent extraction and column chromatography.

    PubMed

    Zhang, Weinong; He, Haibo; Feng, Yuqi; Da, Shilu

    2003-12-25

    Natural phosphatidylcholine (PC) and phosphatidylethanolamine (PE) were separated and purified from soybean degummed oil residues in this work. Crude PC and PE were first separated from degummed oil residues by extraction with 95% ethanol, and then the crude PC and PE were used as raw materials to prepare high purity PC and PE by using column chromatography of silica gel (100-200 mesh) with different eluents and elution modes. The high purity PC (content > 90%) was obtained from the crude PC by using isocratic elution with methanol as eluent. Compared with the methods reported by using isocratic elution with mixed solvents as eluent or gradient elution, the procedure proposed exhibits low cost and industry potentialities because of some advantages, such as operation simplicity, cheap equipment and solvent to be recovered easily. The purity of the PE product prepared from the crude PE was more than 75%. The gradient elution was preferable to isocratic elution for reducing the elution time and eluent consumption when to prepare PE from the crude PE. The effects of loading amount and the flow-rate on separation efficiency were also investigated. For obtaining high separation efficiency, the loading amount should be less than 2.0 g crude PC or PE/100 g silica gel, and the flow-rate should be controlled under 4 ml/min for crude PC and 3 ml/min for crude PE, respectively. PMID:14643513

  6. Determination of sulfonamides by packed column supercritical fluid chromatography with atmospheric pressure chemical ionisation mass spectrometric detection.

    PubMed

    Dost, K; Jones, D C; Davidson, G

    2000-07-01

    Sulfonamide antibiotics are widely used to prevent bacterial infections in livestock, and residues are commonly found in milk and meat. Packed column supercritical fluid chromatography (pSFC) with detection using ultra violet (UV) and atmospheric pressure chemical ionisation (APCI) mass spectrometry (MS) provides a versatile method for the detection and quantification of six major sulfonamides. The APCI mass spectra for all the sulfonamides consisted of protonated molecules at low cone voltages. Increasing the cone voltage led to informative fragmentation patterns, which provided structural information for identification purposes. The pSFC-APCI-MS technique was shown to be linear (r2 > or = 0.999) over the concentration range 0.1-50 micrograms ml-1 using total ion current. The precision and the accuracy of the system and validation of sample preparation are acceptable, with RSD < 2% and relative error 8%. Selected ion monitoring gave detection limits as follows: sulfadiazine 41, sulfamethoxazole 45, sulfamerazine 47, sulfamethizole 59, sulfamethazine 181 and sulfadimethoxine 96 micrograms l-1, which are lower than the amounts permitted in milk products. The APCI pSFC-MS system was shown to have a high degree of reproducibility. The technique was then applied to determine the above sulfonamides in milk. The results obtained show that there are no matrix effects from the milk and that the detection limits remained as stated for the standard solutions. PMID:10984919

  7. Quantification of monosaccharides through multiple-reaction monitoring liquid chromatography/mass spectrometry using an aminopropyl column.

    PubMed

    Hammad, Loubna A; Derryberry, Dakota Z; Jmeian, Yazen R; Mechref, Yehia

    2010-06-15

    A simple, sensitive, and reproducible quantitative liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was designed for the simultaneous quantification of monosaccharides derived from glycoprotein and blood serum using a multiple-reaction monitoring (MRM) approach. Sialic acids and neutral monosaccharides were efficiently separated using an amino-bonded silica phase column. Neutral monosaccharide molecules were detected as their aldol acetate anion adducts [M + CH(3)CO(2)](-) using electrospray ionization in negative ion MRM mode, while sialic acids were detected as deprotonated ions [M-H](-). The new method did not require a reduction step, and exhibited very high sensitivity to carbohydrates with limits of detection of 1 pg for the sugars studied. The linearity of the described approach spanned over three orders of magnitude (pg to ng). The method was validated for monosaccharides originating from N-linked glycans attached to glycoproteins and glycoproteins found in human blood serum. The method effectively quantified monosaccharides originating from as little as 1 microg of glycoprotein and 5 microL of blood serum. The method was robust, reproducible, and highly sensitive. It did not require reduction, derivatization or postcolumn addition of reagents. PMID:20486252

  8. Investigation of the preparation and use of low-capacity anion exchangers in single-column ion chromatography

    SciTech Connect

    Barron, R.E.

    1984-01-01

    The preparation and uses of strong-base anion exchangers of low capacity are reviewed. A new adaptation of known reactions is presented for the reproducible preparation of Type I anion exchangers of low capacity and it is explored in some detail. The resins are based on the macroreticular copolymer known as XAD-1. It is shown that the same reaction scheme may be used on any porous styrene-divinylbenzene copolymer. Procedures are described for the preparation of twelve other strong-base resins with various structural differences in the quaternary ammonium functional group. These resins are then evaluated to determine the effect of chemical structure on selectivity for a number of common monovalent and divalent anions. It is shown that the structure of the quaternary ammonium ion has a definite effect on selectivity. It is also shown that surface modification can affect selectivity. The implications for single-column ion chromatography are discussed and some examples are given where a change in the chemical structure of the functional group is of practical value in the separation of anions. The factors influencing the choice of an eluent acid are outlined and it is shown that some acids are better than others on the basis on their lack of interaction with the copolymer matrix.

  9. Comparison of dieldrin, lindane, and DDT extractions from serum, and gas-liquid chromatography using glass capillary columns.

    PubMed

    Franken, J J; Luyten, B J

    1976-11-01

    Rats were given an oral dose of 14C-labeled chlorinated pesticides to obtain serum containing p,p'-DDT, dieldrin, or lindane. Simple hexane and formic acid-hexane extraction methods, involving pretreatment of the serum with formic acid, were compared by radiometric and by paper chromatographic and gas chromatographic analysis. In vivo binding of chlorinated pesticides to constituents of the serum does not necessarily prohibit their isolation by simple hexane extractions, provided that the extraction is very vigorous and at least 5 min long. Stable emulsions were broken by cooling in liquid nitrogen or Dry Ice-acetone. The hexane extraction method described yields quantitative recovery of the pesticides studied, whereas the formic acid-hexane method is quantitative for p,p'-DDT, 93% for dieldrin, and 89% for lindane. Gas chromatographic comparison of both methods, using human serum, shows that the hexane method extracts 16% more beta-BHC, 7% more dieldrin and HCB, and 4% more p,p'-DDE from serum than does the formic acid-hexane method. The difference for p,p'-DDT is not significant. Gas chromatography with glass capillary columns and an all-glass solids injection system yielded detection limits as low as 15 fg. Data show that the use of an internal standard considerably improves the precision of quantitation. PMID:62748

  10. A new approach for trace analysis of guanidine compounds in surface water with resorcinarene-based ion chromatography columns.

    PubMed

    Panahi, Tayyebeh; Weaver, Douglas J; Lamb, John D; Harrison, Roger G

    2016-02-01

    Trace levels of pharmaceuticals have been detected in surface water and may pose a health risk to humans and other organisms. New chromatographic materials will help identify and quantify these contaminants. We introduce a new ion chromatographic (IC) material designed to separate cationic pharmaceuticals and report its ability to separate a group of guanidine compounds. Guanidine moieties are strongly basic and protonated under acid conditions, and therefore can potentially be separated on the newly designed stationary phase and detected by ion exchange chromatography. The new column packing material is based on glutamic acids bonded to resorcinarene moieties that in turn are bound to divinylbenzene macroporous resin. Detection limits in the range of 5-30 μg L(-1) were achieved using integrated pulsed amperometric detection (IPAD) for guanidine (G), methylguanidine (MG), 1,1-dimethylbiguanide (DMG), agmatine (AGM), guanidinobenzoic acid (GBA) and cimetidine (CIM). Suppressed conductivity (CD) and UV-vis detection resulted in limits of detection similar to IPAD, in the range of 2-66 μg L(-1), but were not able to detect all of the analytes. Three water sources, river, lake, and marsh, were analyzed and despite matrix effects, sensitivity for guanidine compounds was in the 100 μg L(-1) range and apparent recoveries were 80-96%. The peak area precision was 0.01-2.89% for IPAD, CD and UV-vis detection. PMID:26649362

  11. High-performance liquid chromatography method for ferric iron chelators using a post-column reaction with Calcein Blue.

    PubMed

    Ariga, Tomoko; Ito, Kyoko; Imura, Yuki; Yoshimura, Etsuro

    2015-03-15

    Iron (Fe) is an essential element for higher plants, which take it up from the soil at the root surface and transport it to shoots through the xylem. Fe(III) chelators, such as organic acids and phytosiderophores, play important roles in the acquisition and transportation of Fe(III). Therefore, a selective and sensitive method for analyzing Fe(III) chelators is required to study the many Fe-related physiological mechanisms in plants. A novel analytical approach employing a high-performance liquid chromatography post-column method with fluorescence detection was developed to separate and detect Fe(III) chelators. This method takes advantage of the quenching of the fluorescence of Calcein Blue (CB) that occurs with the formation of an Fe(III)-CB complex and the dequenching that occurs with the release of CB as a result of competition for Fe(III) between CB and an Fe(III) chelator. This simple experimental method does not require complicated pretreatments and can selectively detect Fe(III) chelators according to their Fe(III)-chelating ability. The detection limit for citric acid using this method was 72pmol. Furthermore, this method can also detect unknown Fe(III) chelators that exhibit a high affinity for Fe(III). The method was evaluated with xylem sap of barley, which was shown to contain several Fe(III) chelators. PMID:25658515

  12. Adsorption in a Fixed-Bed Column and Stability of the Antibiotic Oxytetracycline Supported on Zn(II)-[2-Methylimidazolate] Frameworks in Aqueous Media

    PubMed Central

    Anceski Bataglion, Giovana; Nogueira Eberlin, Marcos; Machado Ronconi, Célia

    2015-01-01

    A metal-organic framework, Zn-[2-methylimidazolate] frameworks (ZIF-8), was used as adsorbent material to remove different concentrations of oxytetracycline (OTC) antibiotic in a fixed-bed column. The OTC was studied at concentrations of 10, 25 and 40 mg L-1. At 40 mg L-1, the breakthrough point was reached after approximately 10 minutes, while at 10 and 25 mg L-1 this point was reached in about 30 minutes. The highest removal rate of 60% for the 10 mg L-1 concentration was reached after 200 minutes. The highest adsorption capacity (28.3 mg g-1) was attained for 25 mg L-1 of OTC. After the adsorption process, a band shift was observed in the UV-Vis spectrum of the eluate. Additional studies were carried out to determine the cause of this band shift, involving a mass spectrometry (MS) analysis of the supernatant liquid during the process. This investigation revealed that the main route of adsorption consisted of the coordination of OTC with the metallic zinc centers of ZIF-8. The materials were characterized by thermal analysis (TA), scanning electron microscopy (SEM), powder X-ray diffraction (XRD), and infrared spectroscopy (IR) before and after adsorption, confirming the presence of OTC in the ZIF-8 and the latter’s structural stability after the adsorption process. PMID:26057121

  13. Improved Thermal Modulator for Gas Chromatography

    NASA Technical Reports Server (NTRS)

    Hasselbrink, Ernest Frederick, Jr.; Hunt, Patrick J.; Sacks, Richard D.

    2008-01-01

    An improved thermal modulator has been invented for use in a variant of gas chromatography (GC). The variant in question denoted as two-dimensional gas chromatography (2DGC) or GC-GC involves the use of three series-connected chromatographic columns, in the form of capillary tubes coated interiorly with suitable stationary phases (compounds for which different analytes exhibit different degrees of affinity). The two end columns are relatively long and are used as standard GC columns. The thermal modulator includes the middle column, which is relatively short and is not used as a standard GC column: instead, its temperature is modulated to affect timed adsorption and desorption of analyte gases between the two end columns in accordance with a 2DGC protocol.

  14. Trace analysis of heavy metals in groundwater samples by ion chromatography with post-column reaction and ultraviolet-visible detection.

    PubMed

    Santoyo, E; Santoyo-Gutiérrez, S; Verma, S P

    2000-07-01

    Groundwaters originating from local and regional aquifers surrounding ash deposits produced by a coal-fired power plant were collected. These water samples were chemically analyzed for quantifying their heavy metal composition at trace levels. A highly sensitive analytical technique based on ion chromatography with a UV-Vis detector and under isocratic eluent flow-rate conditions was used. In order to quantify the major heavy metals (Pb, Cu, Cd, Co, Zn and Ni), three ionic separation column systems were evaluated: (1) a cationic column (HPIC-CS2, Dionex) tested with two eluents (10 mM oxalic acid-7.5 mM citric acid; and 40 mM D-tartaric acid-12 mM citric acid); (2) an anionic column (HPIC-AS4, Dionex) evaluated with 25 mM oxalic acid as eluent: and (3) a bifunctional ion-exchange column (Ionpac CS5, Dionex) which was also tested with two eluents (6 mM pyridine, 2,6-dicarboxylic acid; and 50 mM oxalic acid/95 mM lithium hydroxide). The lowest detection limits achieved with the Ionpac CS5 column and the 50 mM oxalic acid-95 mM lithium hydroxide eluent enabled the heavy metal analysis in groundwater samples to be reliably performed. Details of this comparative study, including the ion chromatography procedure selected and its application to heavy metal analysis of groundwater samples, are presented in this work. PMID:10917442

  15. A strategy for identification and structural characterization of compounds from Gardenia jasminoides by integrating macroporous resin column chromatography and liquid chromatography-tandem mass spectrometry combined with ion-mobility spectrometry.

    PubMed

    Wang, Lu; Liu, Shu; Zhang, Xueju; Xing, Junpeng; Liu, Zhiqiang; Song, Fengrui

    2016-06-24

    In this paper, an analysis strategy integrating macroporous resin (AB-8) column chromatography and high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) combined with ion mobility spectrometry (IMS) was proposed and applied for identification and structural characterization of compounds from the fruits of Gardenia jasminoides. The extracts of G. jasminoides were separated by AB-8 resin column chromatography combined with reversed phase liquid chromatography (C18 column) and detected by electrospray ionization tandem mass spectrometry. Additionally, ion mobility spectrometry (IMS) was employed as a supplementary separation technique to discover previously undetected isomers from the fruits of G. jasminoides. A total of 71 compounds, including iridoids, flavonoids, triterpenes, monoterpenoids, carotenoids and phenolic acids were identified by the characteristic high resolution mass spectrometry and the ESI-MS/MS fragmentations. In conclusion, the IMS-MS technique achieved the separation of isomers in crocin-3 and crocin-4 according to their acquired mobility drift times differing from classical analysis by mass spectrometry. The proposed strategy can be used as a highly sensitive and efficient procedure for identification and separation isomeric components in extracts of herbal medicines. PMID:27208986

  16. BRIEF COMMUNICATIONS: Laser chromatography (negative results)

    NASA Astrophysics Data System (ADS)

    Kuz'menko, V. A.

    1989-11-01

    An experimental study was made of the influence of cw CO2 laser radiation on gas-adsorption chromatography of SF6, CH2Cl2, and BCl3. Resonant excitation of molecules by laser radiation did not alter the duration of their retention in a chromatograph column. A reduction in the retention time was attributed to nonresonant heating of the column walls by laser radiation.

  17. A Microfluidic Device for Preparing Next Generation DNA Sequencing Libraries and for Automating Other Laboratory Protocols That Require One or More Column Chromatography Steps

    PubMed Central

    Tan, Swee Jin; Phan, Huan; Gerry, Benjamin Michael; Kuhn, Alexandre; Hong, Lewis Zuocheng; Min Ong, Yao; Poon, Polly Suk Yean; Unger, Marc Alexander; Jones, Robert C.; Quake, Stephen R.; Burkholder, William F.

    2013-01-01

    Library preparation for next-generation DNA sequencing (NGS) remains a key bottleneck in the sequencing process which can be relieved through improved automation and miniaturization. We describe a microfluidic device for automating laboratory protocols that require one or more column chromatography steps and demonstrate its utility for preparing Next Generation sequencing libraries for the Illumina and Ion Torrent platforms. Sixteen different libraries can be generated simultaneously with significantly reduced reagent cost and hands-on time compared to manual library preparation. Using an appropriate column matrix and buffers, size selection can be performed on-chip following end-repair, dA tailing, and linker ligation, so that the libraries eluted from the chip are ready for sequencing. The core architecture of the device ensures uniform, reproducible column packing without user supervision and accommodates multiple routine protocol steps in any sequence, such as reagent mixing and incubation; column packing, loading, washing, elution, and regeneration; capture of eluted material for use as a substrate in a later step of the protocol; and removal of one column matrix so that two or more column matrices with different functional properties can be used in the same protocol. The microfluidic device is mounted on a plastic carrier so that reagents and products can be aliquoted and recovered using standard pipettors and liquid handling robots. The carrier-mounted device is operated using a benchtop controller that seals and operates the device with programmable temperature control, eliminating any requirement for the user to manually attach tubing or connectors. In addition to NGS library preparation, the device and controller are suitable for automating other time-consuming and error-prone laboratory protocols requiring column chromatography steps, such as chromatin immunoprecipitation. PMID:23894273

  18. Determination of trans-10-hydroxy-2-decenoic acid content in pure royal jelly and royal jelly products by column liquid chromatography.

    PubMed

    Genç, M; Aslan, A

    1999-04-16

    In this research, several royal jellies and commercial products containing royal jelly were analysed for their trans-10-hydroxy-2-decenoic acid (10-HDA) content by using a column liquid chromatography technique. Ten samples claimed to be pure royal jelly, containing 10-HDA between 0.75 and 2.54%. Seven samples claimed to contain royal jelly as an ingredient which ranged from non-detectable to 0.054%. The technique was found to be rapid with high recovery. PMID:10327631

  19. Chromatography

    MedlinePlus

    ... a way of separating two or more chemical compounds. Chemical compounds are chemicals that are bonded together. For example, ... and hydrogen. Proteins are another type of chemical compound. There are different kinds of chromatography. These include ...

  20. Capillary ion chromatography with on-column focusing for ultra-trace analysis of methanesulfonate and inorganic anions in limited volume Antarctic ice core samples.

    PubMed

    Rodriguez, Estrella Sanz; Poynter, Sam; Curran, Mark; Haddad, Paul R; Shellie, Robert A; Nesterenko, Pavel N; Paull, Brett

    2015-08-28

    Preservation of ionic species within Antarctic ice yields a unique proxy record of the Earth's climate history. Studies have been focused until now on two proxies: the ionic components of sea salt aerosol and methanesulfonic acid. Measurement of the all of the major ionic species in ice core samples is typically carried out by ion chromatography. Former methods, whilst providing suitable detection limits, have been based upon off-column preconcentration techniques, requiring larger sample volumes, with potential for sample contamination and/or carryover. Here, a new capillary ion chromatography based analytical method has been developed for quantitative analysis of limited volume Antarctic ice core samples. The developed analytical protocol applies capillary ion chromatography (with suppressed conductivity detection) and direct on-column sample injection and focusing, thus eliminating the requirement for off-column sample preconcentration. This limits the total sample volume needed to 300μL per analysis, allowing for triplicate sample analysis with <1mL of sample. This new approach provides a reliable and robust analytical method for the simultaneous determination of organic and inorganic anions, including fluoride, methanesulfonate, chloride, sulfate and nitrate anions. Application to composite ice-core samples is demonstrated, with coupling of the capillary ion chromatograph to high resolution mass spectrometry used to confirm the presence and purity of the observed methanesulfonate peak. PMID:26206628

  1. [Purification of enramycin by macroporous resin adsorption and reversed phase chromatography purification].

    PubMed

    Jiaxin, Wu; Yongdong, Huang; Peng, Qi; Jihong, He; Ping, Li; Guodong, Zhang; Meixian, Zhao

    2014-11-01

    Enramycin is a polypeptide antibiotic and new, safe animal feed additive. A new purification process was developed, based on pre-purification by macroporous resin and refining by reversed phase chromatography. AB-8 macroporous resin was used for the pre-purification process of enramycin, with an elution buffer of 0.012 mol/L aqueous HCl solution-methanol (50: 50, V/V). Then, enramycin a and enramycin b were separated effectively by C18 reversed phase chromatography, with a elution buffer of 0.05 mol/L aqueous KH2PO4 solution-acetonitrile (70: 30, V/V, pH 4.5). The purities of enramycin a and enramycin b were up to 98.5% and 98.0%, respectively. The yield reached 29.2%. This study would provide a useful reference for the preparation of enramycin a and enramycin b with a high purity. PMID:25985521

  2. Online micro-solid-phase extraction based on boronate affinity monolithic column coupled with high-performance liquid chromatography for the determination of monoamine neurotransmitters in human urine.

    PubMed

    Yang, Xiaoting; Hu, Yufei; Li, Gongke

    2014-05-16

    Quantification of monoamine neurotransmitters is very important in diagnosing and monitoring of patients with neurological disorders. We developed an online analytical method to selectively determine urinary monoamine neurotransmitters, which coupled the boronate affinity monolithic column micro-solid-phase extraction with high-performance liquid chromatography (HPLC). The boronate affinity monolithic column was prepared by in situ polymerization of vinylphenylboronic acid (VPBA) and N,N'-methylenebisacrylamide (MBAA) in a stainless capillary column. The prepared monolithic column showed good permeability, high extraction selectivity and capacity. The column-to-column reproducibility was satisfactory and the enrichment factors were 17-243 for four monoamine neurotransmitters. Parameters that influence the online extraction efficiency, including pH of sample solution, flow rate of extraction and desorption, extraction volume and desorption volume were investigated. Under the optimized conditions, the developed method exhibited low limit of detection (0.06-0.80μg/L), good linearity (with R(2) between 0.9979 and 0.9993). The recoveries in urine samples were 81.0-105.5% for four monoamine neurotransmitters with intra- and inter-day RSDs of 2.1-8.2% and 3.7-10.6%, respectively. The online analytical method was sensitive, accurate, selective, reliable and applicable to analysis of trace monoamine neurotransmitters in human urine sample. PMID:24703360

  3. Development and characterization of a chitosan-supported immunoaffinity chromatography column for the selective extraction of methandrostenolone from food and feed samples.

    PubMed

    Wang, Yun; Xu, Yan; Zhang, Xun; Wang, Enlan; Dong, Ying

    2011-10-01

    The development of a chitosan-supported immunoaffinity chromatography (IAC) column and its application to the selective extraction of methandrostenolone (MA) from food and feed samples were described in this paper. Using hybridoma technique, a monoclonal antibody (mAb) against MA was produced. The IAC column was prepared by coupling the produced antibody with crosslinked chitosan. Scanning electron microscopy and IR spectroscopy was used to characterize the chitosan crosslinking and antibody coupling. 2% and 90% methanol were respectively selected as loading and eluting solution by optimization. The maximum capacity of the column for MA was 1790ng/mL gel. The extraction recoveries of the column for MA at three different spiked concentrations ranged from 83.7 to 98.5%. After 2 cycles of usage, the column capacity and extraction recovery still remained 84.6% and 80.5%. To further verify the effect of matrix on the IAC cleanup, MA-fortified food and feed samples were extracted using the prepared IAC column, and MA recovery rates were found to be 86.2% and 70.4%, respectively. PMID:21664371

  4. Development of an immunoaffinity chromatography column for selective extraction of a new agonist phenylethylamine A from feed, meat and liver samples.

    PubMed

    Mei, Liyun; Cao, Biyun; Yang, Hong; Xie, Yun; Xu, Shouming; Deng, Anping

    2014-01-15

    Phenylethanolamine A (PA) is a new emerged β-adrenergic agonist that has been illegally used as an animal feed additive for growth promotion in China. In this study, an immunoaffinity chromatography (IAC) column for selective extraction of PA from swine feed, meat and liver samples was developed. The IAC column was constructed by covalently coupling specific polyclonal antibody (Ab) against PA to CNBr-activated Sepharose 4B and packed into a common solid phase extraction (SPE) cartridge. The extraction conditions including loading, washing and eluting solutions were carefully optimized. Under optimal conditions, the IAC column was characterized in terms of maximum capacity, selectivity, extraction recovery and stability. The maximum capacity of the ICA for PA extraction was found to be 239.4ng. For selectivity testing, 100ng of other three β-adrenergic agonists (clenbuterol, ractopamine and salbutamol) was separately loaded onto the column, and it was observed that the tested compounds could not be captured on the column, e.g. the column could only selectively recognize PA. The recovery of the IAC for PA extraction was found within 96.47-101.98% when 10, 50 and 100ng PA were separately loaded onto IAC column. The IAC column was also applied to real sample extraction. Swine feed, meat and liver samples were collected and spiked with PA in range of 1.0-20ngg(-1). The spiked and unspiked samples were extracted by IAC column and measured by high performance liquid chromatography (HPLC). It was found that there was no detectable PA in the blank samples, and the extraction recoveries of the IAC for PA from the spiked samples were within 89.48-104.89%. The stability of the column was also tested. It was showed that after 35 times repeated usage, 60% of the maximum capacity was still remained. The proposed IAC was proven to be a feasible extraction method for PA from different matrices with the properties of high maximum capacity, selectivity, extraction efficiency and

  5. [Determination of 11 anabolic hormones in fish tissue by multi-function impurity adsorption solid-phase extraction-ultrafast liquid chromatography-tandem mass spectrometry].

    PubMed

    Yao, Shanshan; Zhao, Yonggang; Li, Xiaoping; Chen, Xiaohong; Jin, Micong

    2012-06-01

    A method was developed for the determination of 11 anabolic hormones (boldenone, androstenedione, nandrolone, methandrostenolone, methyltestosterone, testosterone, testosterone acetate, trenbolone, testosterone propionate, stanozolol, fluoxymesterone) in fish by multi-function impurity adsorption solid-phase extraction-ultrafast liquid chromatography-tandem mass spectrometry. After the sample was extracted by methanol, the extract was cleaned-up quickly by C18 adsorbent, neutral alumina adsorbent and amino-functionalized nano-adsorbent. The separation was performed on a Shim-Pack XR-ODS II column (100 mm x 2.0 mm, 2.2 microm) using the mobile phases of 0.1% (v/v) formic acid in acetonitrile and 0.1% (v/v) formic acid solution in a gradient elution mode. The identification and quantification were achieved by using electrospray ionization in positive ion mode (ESI+) in multiple reaction monitoring (MRM) mode. The matrix-matched external standard calibration curves were used for quantitative determination. The results showed that the calibration curves were in good linearity for the eleven analytes with the correlation coefficients (r) more than 0.999. The limits of detection (LODs, S/N > 3) for the 11 anabolic hormones were from 0.03 microg/kg to 0.4 microg/kg and the limits of quantification (LOQs, S/N > 10) were from 0.1 microg/kg to 1.5 microg/kg. The average recoveries ranged from 80.9% to 98.1% with the relative standard deviations between 5.2% and 11.5%. The method is simple, rapid, sensitive, accurate and suitable for the quantitative determination and confirmation of the 11 anabolic hormones in fish. PMID:23016290

  6. Screening and confirmation of thyreostatics in urine by gas chromatography with nitrogen-phosphorus detection and gas chromatography-mass spectrometry after sample clean-up with a mercurated affinity column.

    PubMed

    Schilt, R; Weseman, J M; Hooijerink, H; Korbee, H J; Traag, W A; van Steenbergen, M J; Haasnoot, W

    1989-04-01

    Methods are described for the screening and confirmation of residues of the thyreostatics thiouracil, methylthiouracil and propylthiouracil in urine samples of cattle at levels down to 25 micrograms/l. After a selective preconcentration of the thiol-containing thyreostatics on a mercurated affinity column, the analytes are derivatized by extractive alkylation and analysed by gas chromatography with nitrogen-phosphorus or mass spectrometric detection. PMID:2745644

  7. Amphiphilic agarose-based adsorbents for chromatography. Comparative study of adsorption capacities and desorption efficiencies.

    PubMed

    Oscarsson, S; Angulo-Tatis, D; Chaga, G; Porath, J

    1995-01-01

    A number of hydrophobic derivatives attached to cross-linked agarose were studied as protein adsorbents. Differences in the adsorption and desorption behaviour were determined as functions of type and concentration of selected salts. Whereas octyl- and phenyl-Sepharose adsorb serum albumin preferentially, pyridyl-S-agarose shows a much stronger preferential affinity for IgG in the presence of high concentrations of lyotropic salts, such as sulphates. In contrast to pyridyl-S-agarose, a large portion of proteins remained fixed to octyl- and phenyl-Sepharose after extensive washing with 1 M NaOH. PMID:7881534

  8. Relating pressure tuned coupled column ensembles with the solvation parameter model for tunable selectivity in gas chromatography.

    PubMed

    Sharif, Khan M; Kulsing, Chadin; Chin, Sung-Tong; Marriott, Philip J

    2016-07-15

    The differential pressure drop of carrier gas by tuning the junction point pressure of a coupled column gas chromatographic system leads to a unique selectivity of the overall separation, which can be tested using a mixture of compounds with a wide range of polarity. This study demonstrates a pressure tuning (PT) GC system employing a microfluidic Deans switch located at the mid-point of the two capillary columns. This PT system allowed variations of inlet-outlet pressure differences of the two columns in a range of 52-17psi for the upstream column and 31-11psi for the downstream column. Peak shifting (differential migration) of compounds due to PT difference are related to a first order regression equation in a Plackett-Burman factorial study. Increased first (upstream) column pressure drop makes the second column characteristics more significant in the coupled column retention behavior, and conversely increased second (downstream) column pressure drop makes the first column characteristics more apparent; such variation can result in component swapping between polar and non-polar compounds. The coupled column system selectivity was evaluated in terms of linear solvation energy relationship (LSER) parameters, and their relation with different pressure drop effects has been constructed by applying multivariate principle component analysis (PCA). It has been found that the coupled column PT system descriptors provide a result that shows a clear clustering of different pressure settings, somewhat intermediate between those of the two commercial columns. This is equivalent to that obtained from a conventional single-column GC analysis where the interaction energy contributed from the stationary phases can be significantly adjusted by choice of midpoint PT. This result provides a foundation for pressure differentiation for selectivity enhancement. PMID:27302688

  9. Monolithic stationary phases with incorporated fumed silica nanoparticles. Part II. Polymethacrylate-based monolithic column with "covalently" incorporated modified octadecyl fumed silica nanoparticles for reversed-phase chromatography.

    PubMed

    Aydoğan, Cemil; El Rassi, Ziad

    2016-05-01

    This study is concerned with the incorporation of surface modified fumed silica nanoparticles (FSNPs) into polymethacrylate based monolithic columns for use in reversed phase chromatography (RPC) of small solutes and proteins. First, FSNPs were modified with 3-(trimethoxysilyl)propylmethacrylate (TMSPM) to yield the "hybrid" methacryloyl fumed silica nanoparticle (MFSNP) monomer. The resulting MFSNP was then mixed with glyceryl monomethacrylate (GMM) and ethylene dimethacrylate (EDMA) in a binary porogenic solvent composed of cyclohexanol and dodecanol, and the in situ copolymerization of MFSNP, GMM and EDMA was performed in a stainless steel column of 4.6 mm i.d. The silanol groups of the hybrid monolith thus obtained were grafted with octadecyl ligands by perfusing the hybrid monolithic column with a solution of 4% w/v of dimethyloctadecylchlorosilane (DODCS) in toluene while the column was maintained at 110°C for 6h (in a heated HPLC oven). One of the originalities of this study was to demonstrate MFSNP as a novel derivatized "hybrid monomer" in making RPC monolithic columns with surface bound octadecyl ligands. In this respect, the RPC behavior of the monolithic column with "covalently" incorporated FNSPs having surface grafted octadecyl ligands was evaluated with alkylbenzenes, aniline derivatives and phenolic compounds. The results showed that the hybrid poly(GMA-EDMA-MFSNP) having surface bound octadecyl ligands exhibited hydrophobic interactions under reversed phase elution conditions. Furthermore, six standard proteins were baseline separated on the column using a 10min linear gradient elution at increasing ACN concentration in the mobile phase at a flow rate of 1.0mL/min using a 10 cm×4.6mm i.d. column. The relative standard deviations (RSDs) for the retention times of the tested solutes were lower than 2.1% and 2.4% under isocratic elution and gradient elution conditions, respectively. PMID:27059396

  10. Column dynamic studies and breakthrough curve analysis for Cd(II) and Cu(II) ions adsorption onto palm oil boiler mill fly ash (POFA).

    PubMed

    Aziz, Abdul Shukor Abdul; Manaf, Latifah Abd; Man, Hasfalina Che; Kumar, Nadavala Siva

    2014-01-01

    This paper investigates the adsorption characteristics of palm oil boiler mill fly ash (POFA) derived from an agricultural waste material in removing Cd(II) and Cu(II) from aqueous solution via column studies. The performance of the study is described through the breakthrough curves concept under relevant operating conditions such as column bed depths (1, 1.5, and 2 cm) and influent metal concentrations (5, 10, and 20 mg/L). The Cd(II) and Cu(II) uptake mechanism is particularly bed depth- and concentration-dependant, favoring higher bed depth and lower influent metal concentration. The highest bed capacity of 34.91 mg Cd(II)/g and 21.93 mg Cu(II)/g of POFA was achieved at 20 mg/L of influent metal concentrations, column bed depth of 2 cm, and flow rate of 5 mL/min. The whole breakthrough curve simulation for both metal ions were best described using the Thomas and Yoon–Nelson models, but it is apparent that the initial region of the breakthrough for Cd(II) was better described using the BDST model. The results illustrate that POFA could be utilized effectively for the removal of Cd(II) and Cu(II) ions from aqueous solution in a fixed-bed column system. PMID:24659435

  11. Simultaneous determination of iodide and iodate in povidone iodine solution by ion chromatography with homemade and exchange capacity controllable columns and column-switching technique.

    PubMed

    Huang, Zhongping; Zhu, Zuoyi; Subhani, Qamar; Yan, Wenwu; Guo, Weiqiang; Zhu, Yan

    2012-08-17

    A simple ion chromatographic method for simultaneous detection of iodide and iodate in a single running was proposed, with columns packed with homemade functionalized polystyrene-divinylbenzene (PS-DVB) resins and column-switching technique. Homemade resins were functionalized with controllable amounts of quaternary ammonium groups. The low-capacity anion-exchange column and high-capacity anion-exchange column were prepared, due to the resins having different exchange capacities. With this method, iodide and iodate in povidone iodine solution were detected simultaneously in a short time with iodide being eluted off first. A series of standard solutions consisting of target anions of various concentrations from 0.01 mg/L to 100 mg/L were analyzed. Each anion exhibited satisfactory linearity, with correlation coefficient r ≥ 0.9990. The detection limits (LODs) for iodide and iodate obtained by injecting 100 μL of sample were 5.66 and 14.83 μg/L (S/N=3), respectively. A spiking study was performed with satisfactory recoveries between 101.2% and 100.6% for iodide and iodate. PMID:22771256

  12. Serum acetaminophen assay using activated charcoal adsorption and gas chromatography without derivatization.

    PubMed

    Jeevanandam, M; Novic, B; Savich, R; Wagman, E

    1980-01-01

    A quantitative assay of acetaminophen in serum has been developed. The drug, together with an internal standard 2-acetamidophenol, is adsorbed on activated charcoal and then extracted into a mixture of ethyl acetate and isopropanol. This extract is then analyzed, without any derivatization, by gas chromatography. The isothermal analysis yielded a good, highly reproducible separation. The drug peak was symmetrical and without any tailing. The peak height response ratio was found to be linear with concentrations ranging from 25-500 ng/L. No interference was observed with the various drugs or metabolites which are commonly encountered in human serum. PMID:7421146

  13. Determination of adsorbable organic fluorine from aqueous environmental samples by adsorption to polystyrene-divinylbenzene based activated carbon and combustion ion chromatography.

    PubMed

    Wagner, Andrea; Raue, Brigitte; Brauch, Heinz-Jürgen; Worch, Eckhard; Lange, Frank T

    2013-06-21

    A new method for the determination of trace levels of adsorbable organic fluorine (AOF) in water is presented. Even if the individual contributing target compounds are widely unknown, this surrogate parameter is suited to identify typical organofluorine contaminations, such as with polyfluorinated chemicals (PFCs), and represents a lower boundary of the organofluorine concentration in water bodies. It consists of the adsorption of organofluorine chemicals on a commercially available synthetic polystyrene-divinylbenzene based activated carbon (AC) followed by analysis of the loaded AC by hydropyrolysis combustion ion chromatography (CIC). Inorganic fluorine is displaced by excess nitrate during the extraction step and by washing the loaded activated carbon with an acidic sodium nitrate solution. Due to its high purity the synthetic AC had a very low and reproducible fluorine blank (0.3 μg/g) compared to natural ACs (up to approximately 9 μg/g). Using this AC, fluoride and the internal standard phosphate could be detected free of chromatographic interferences. With a sample volume of 100 mL and 2× 100 mg of AC packed into two extraction columns combined in series, a limit of quantification (LOQ), derived according to the German standard method DIN 32645, of 0.3 μg/L was achieved. The recoveries of six model PFCs were determined from tap water and a municipal wastewater treatment plant (WWTP) effluent. Except for the extremely polar perfluoroacetic acid (recovery of approximately 10%) the model substances showed fairly good (50% for perfluorobutanoic acid (PFBA)) to very good fluorine recoveries (100±20% for perfluorooctanoic acid (PFOA), perfluorobutanesulfonate (PFBS), 6:2 fluorotelomersulfonate (6:2 FTS)), both from tap water and wastewater matrix. This new analytical protocol was exemplarily applied to several surface water and groundwater samples. The obtained AOF values were compared to the fluorine content of 19 target PFCs analyzed by high performance

  14. Low-coverage adsorption properties of the metal-organic framework MIL-47 studied by pulse chromatography and Monte Carlo simulations.

    PubMed

    Finsy, Vincent; Calero, Sofia; García-Pérez, Elena; Merkling, Patrick J; Vedts, Gill; De Vos, Dirk E; Baron, Gino V; Denayer, Joeri F M

    2009-05-14

    Low-coverage adsorption properties of the metal-organic framework MIL-47 were determined by a combined experimental and simulation study. Henry constants and low coverage adsorption enthalpies of C5-C8 linear and branched alkanes, cyclohexane and benzene were measured from 120 to 240 degrees C using pulse gas chromatography. An adapted force field for linear and branched alkanes in MIL-47 was used to compute the adsorption properties of those molecules. A new set of charges was developed for simulations with benzene in MIL-47. The adsorption enthalpy of linear alkanes increases with about 7.6 kJ mol(-1) per additional -CH2- group. Henry adsorption constants of iso-alkanes are slightly lower than those of the linear chains but the MIL-47 framework is not imposing steric constraints on the branched chains. Benzene and cyclohexane are adsorbed less strongly than n-hexane as they have less hydrogen atoms. For the studied non-polar molecules, the adsorption energies are dominated by van der Waals interactions and benzene adsorption is additionally influenced by Coulombic interactions. The simulated tendencies are in good agreement with the experiments. PMID:19421556

  15. Determination of the two major human metabolites of tipredane in human urine by high-performance liquid chromatography with column switching.

    PubMed

    Bayliss, M A; Baker, P R; Wilkinson, D

    1997-06-20

    An automated method based on column-switching reversed-phase in high-performance liquid chromatography the heart-cutting mode has been developed for the simultaneous determination of the two major human metabolites of tipredane, FPL 66365XX and FPL 66366XX, in human urine. The limit of quantification of the method was 25 ng/ml for both analytes from a urine injection volume of 100 microl. The intra- and inter-assay precision and accuracy were acceptable between 25 and 5000 ng/ml. No significant interferences were observed from either tipredane or a selection of its putative metabolites, or urine constituents in samples from male and female volunteers. Both analytes were found to be stable in human urine when stored at room temperature for two days, at 4 degrees C for six days, in a freezer at or below -20 degrees C for three weeks, and when the urine samples were subjected to three freeze-thaw cycles The method was unusual in that the initial separation was performed on a non-polar, octadecylsilane, column and the final separation on a more polar, trimethylsilane column. These columns were selected only after the investigation of a wide range of reversed-phase columns. The method's success was based on the greatly differing selectivities shown towards the two analytes by the organic modifiers, methanol and acetonitrile, present in the mobile phases used for the extraction and analytical stages PMID:9234864

  16. Colloidal activated carbon for in-situ groundwater remediation--Transport characteristics and adsorption of organic compounds in water-saturated sediment columns.

    PubMed

    Georgi, Anett; Schierz, Ariette; Mackenzie, Katrin; Kopinke, Frank-Dieter

    2015-08-01

    Colloidal activated carbon can be considered as a versatile adsorbent and carrier material for in-situ groundwater remediation. In analogy to other nanoremediation approaches, activated carbon colloids (ACC) can be injected into the subsurface as aqueous suspensions. Deposition of ACC on the sediment creates a sorption barrier against further spreading of hydrophobic pollutants. This study deals with the optimization of ACC and their suspensions with a focus on suspension stability, ACC mobility in saturated porous media and sorption efficiency towards organic contaminants. ACC with an appropriate particle size range (d50=0.8μm) were obtained from a commercial powdered activated carbon product by means of wet-grinding. Among the various methods tested for stabilization of ACC suspensions, addition of humic acid (HA) and carboxymethyl cellulose (CMC) showed the best results. Due to electrosteric stabilization by adsorption of CMC, suspensions remained stable even at high ACC concentrations (11gL(-1)) and conditions typical of very hard water (5mM divalent cations). Furthermore, CMC-stabilized ACC showed high mobility in a water-saturated sandy sediment column (filter coefficient λ=0.2m(-1)). Such mobility is a pre-requisite for in-situ installation of sorption or reaction barriers by simple injection-well or direct-push application of ACC suspensions. Column experiments with organic model compounds proved the efficacy of ACC deposits on sediment for contaminant adsorption and retardation under flow-through conditions. PMID:26070009

  17. Highly Sensitive Determination of 2,4,6-Trinitrotoluene and Related Byproducts Using a Diol Functionalized Column for High Performance Liquid Chromatography

    PubMed Central

    Gumuscu, Burcu; Erdogan, Zeynep; Guler, Mustafa O.; Tekinay, Turgay

    2014-01-01

    In this work, a new detection method for complete separation of 2,4,6-trinitrotoluene (TNT); 2,4-dinitrotoluene (2,4-DNT); 2,6-dinitrotoluene (2,6-DNT); 2-aminodinitrotoluene (2-ADNT) and 4-aminodinitrotoluene (4-ADNT) molecules in high-performance liquid-chromatography (HPLC) with UV sensor has been developed using diol column. This approach improves on cost, time, and sensitivity over the existing methods, providing a simple and effective alternative. Total analysis time was less than 13 minutes including column re-equilibration between runs, in which water and acetonitrile were used as gradient elution solvents. Under optimized conditions, the minimum resolution between 2,4-DNT and 2,6-DNT peaks was 2.06. The recovery rates for spiked environmental samples were between 95–98%. The detection limits for diol column ranged from 0.78 to 1.17 µg/L for TNT and its byproducts. While the solvent consumption was 26.4 mL/min for two-phase EPA and 30 mL/min for EPA 8330 methods, it was only 8.8 mL/min for diol column. The resolution was improved up to 49% respect to two-phase EPA and EPA 8330 methods. When compared to C-18 and phenyl-3 columns, solvent usage was reduced up to 64% using diol column and resolution was enhanced approximately two-fold. The sensitivity of diol column was afforded by the hydroxyl groups on polyol layer, joining the formation of charge-transfer complexes with nitroaromatic compounds according to acceptor-donor interactions. Having compliance with current requirements, the proposed method demonstrates sensitive and robust separation. PMID:24905826

  18. Monolithic stationary phases with incorporated fumed silica nanoparticles. Part I. Polymethacrylate-based monolithic column with incorporated bare fumed silica nanoparticles for hydrophilic interaction liquid chromatography.

    PubMed

    Aydoğan, Cemil; El Rassi, Ziad

    2016-05-01

    Fumed silica nanoparticles (FSNPs), were incorporated for the first time into a polymethacrylate monolithic column containing glyceryl monomethacrylate (GMM) and ethylene dimethacrylate (EDMA) in order to develop a new monolithic column for hydrophilic interaction high performance liquid chromatography (HILIC). When compared to poly(GMM-EDMA) monolithic column without FSNPs, the same monolithic column with incorporated FSNPs yielded important effects on HILIC separations. The effects of monomers and FSNPs content of the polymerization mixture on the performance of the monolithic column were examined in details, and the optimized stationary phase was investigated over a wide range of mobile phase composition with polar acidic, weakly basic and neutral analytes including hydroxy benzoic acids, nucleotides, nucleosides, dimethylformamide, formamide and thiourea. The retention of these analytes was mainly controlled by hydrophilic interactions with the FSNPs and electrostatic repulsion from the negatively charged silica surface in the case of hydroxy benzoic acids and nucleotides. The electrostatic repulsion was minimized by decreasing the pH of the aqueous component of the mobile phase, which in turn enhanced the retention of acidic solutes. Nucleotides were best separated using step gradient elution at decreasing pH as well as ACN concentration in the mobile phase. Improved peak shape and faster analysis of nucleosides were attained by a fast linear gradient elution with a shallow decrease in the ACN content of the ACN-rich mobile phase. The run-to-run and column-to-column reproducibility were satisfactory. The percent relative standard deviations (%RSDs) for the retention times of tested solutes were lower than 2.5% under isocratic conditions and lower than 3.5 under gradient conditions. PMID:27059399

  19. Evaluation of the separation characteristics of application-specific (volatile organic compounds) open-tubular columns for gas chromatography.

    PubMed

    Poole, Colin F; Qian, Jing; Kiridena, Waruna; Dekay, Colleen; Koziol, Wladyslaw W

    2006-11-17

    The solvation parameter model is used to characterize the separation characteristics of two application-specific open-tubular columns (Rtx-Volatiles and Rtx-VGC) and a general purpose column for the separation of volatile organic compounds (DB-WAXetr) at five equally spaced temperatures over the range 60-140 degrees C. System constant differences and retention factor correlation plots are then used to determine selectivity differences between the above columns and their closest neighbors in a large database of system constants and retention factors for forty-four open-tubular columns. The Rtx-Volatiles column is shown to have separation characteristics predicted for a poly(dimethyldiphenylsiloxane) stationary phase containing about 16% diphenylsiloxane monomer. The Rtx-VGC column has separation properties similar to the poly(cyanopropylphenyldimethylsiloxane) stationary phase containing 14% cyanopropylphenylsiloxane monomer DB-1701 for non-polar and dipolar/polarizable compounds but significantly different characteristics for the separation of hydrogen-bond acids. For all practical purposes the DB-WAXetr column is shown to be selectivity equivalent to poly(ethylene glycol) columns prepared using different chemistries for bonding and immobilizing the stationary phase. Principal component analysis and cluster analysis are then used to classify the system constants for the above columns and a sub-database of eleven open-tubular columns (DB-1, HP-5, DB-VRX, Rtx-20, DB-35, Rtx-50, Rtx-65, DB-1301, DB-1701, DB-200, and DB-624) commonly used for the separation of volatile organic compounds. A rationale basis for column selection based on differences in intermolecular interactions is presented as an aid to method development for the separation of volatile organic compounds. PMID:16996069

  20. Determination of some aliphatic carboxylic acids in anaerobic digestion process waters by ion-exclusion chromatography with conductimetric detection on a weakly acidic cation-exchange resin column.

    PubMed

    Ito, Kazuaki; Takayama, Yohichi; Ikedo, Mikaru; Mori, Masanobu; Taoda, Hiroshi; Xu, Qun; Hu, Wenzhi; Sunahara, Hiroshi; Hayashi, Tsuneo; Sato, Shinji; Hirokawa, Takeshi; Tanaka, Kazuhiko

    2004-06-11

    The determination of seven aliphatic carboxylic acids, formic, acetic, propionic, isobutyric, n-butyric, isovaleric and n-valeric acids in anaerobic digestion process waters was examined using ion-exclusion chromatography with conductimetric detection. The analysis of these biologically important carboxylic acids is necessary as a measure for evaluating and controlling the process. The ion-exclusion chromatography system employed consisted of polymethacrylate-based weakly acidic cation-exchange resin columns (TSKgel OApak-A or TSKgel Super IC-A/C). weakly acidic eluent (benzoic acid), and conductimetric detection. Particle size and cation-exchange capacity were 5 microm and 0.1 meq./ml for TSKgel OApak-A and 3 microm and 0.2 meq./ml for TSKgel Super IC-A/C, respectively. A dilute eluent (1.0-2.0 mM) of benzoic acid was effective for the high resolution and highly conductimetric detection of the carboxylic acids. The good separation of isobutyric and n-butyric acids was performed using the TSKgel Super IC-A/C column (150 mm x 6.0 mm i.d. x 2). The simple and good chromatograms were obtained by the optimized ion-exclusion chromatography conditions for real samples from mesophilic anaerobic digestors, thus the aliphatic carboxylic acids were successfully determined without any interferences. PMID:15250416

  1. Determination of coumarin anticoagulant rodenticide residues in animal tissue by high-performance liquid chromatography. I. Fluorescence detection using post-column techniques.

    PubMed

    Hunter, K

    1983-11-18

    A multi-residue method was developed for the determination of the rodenticides warfarin, coumatetralyl, bromadiolone, difenacoum and brodifacoum in animal tissues by high-performance liquid chromatography with fluorescence detection. Extracts were cleaned-up by gel permeation chromatography on Bio-Beads SX-3 and residues determined by normal and reversed-phase high-performance liquid chromatography using post-column pH-switching, with chloroform -sec.-butylamine and borate buffer (pH 10.4) respectively, to maximise the native fluorimetric responses. Confirmation of identification was possible by re-chromatographing extracts in the absence of the post-column reagent. Chloroform-acetone (1:1) was significantly better than chloroform for the extraction of residues of these rodenticides from liver tissues. Recoveries from spiked liver tissue were generally greater than 90% at levels of 0.05-1 mg kg-1. Detection limits in animal tissues of 0.002 mg kg-1 for coumatetratyl, difenacoum and brodifacoum, 0.01 mg kg-1 for bromadiolone and 0.02 mg kg-1 for warfarin and could be routinely achieved. PMID:6655019

  2. An Eco-Friendly Direct Injection HPLC Method for Methyldopa Determination in Serum by Mixed-Mode Chromatography Using a Single Protein-Coated Column.

    PubMed

    Emara, Samy; Masujima, Tsutomu; Zarad, Walaa; Kamal, Maha; Fouad, Marwa; El-Bagary, Ramzia

    2015-09-01

    A simple, rapid and environment-friendly direct injection HPLC method for the determination of methyldopa (MTD) in human serum has been developed and validated. The method was based on cleanup and separation of MTD from serum by mixed-mode liquid chromatography using a single protein-coated TSK gel ODS-80 TM analytical column (50 × 4.0 mm i.d., 5 µm). The protein-coated column exhibited excellent resolution, selectivity and functioned in two chromatographic modes: size-exclusion chromatography [i.e., solid-phase extraction (SPE) for serum proteins] and reversed-phase chromatography for the final separation of MTD. SPE and HPLC separation were carried out simultaneously with a green mobile phase consisting of acetate buffer (0.1 M, pH 2.4) at a flow rate of 1 mL/min and at room temperature (23 ± 1°C). The eluent was monitored at emission and excitation wavelengths of 320 and 270 nm, respectively. A calibration curve was linear over the range of 0.1-30 µg/mL with a detection limit of 0.027 µg/mL. This online SPE method was successfully applied to real samples obtained from patients receiving MTD therapy. PMID:25834172

  3. Phosphate Adsorption using Modified Iron Oxide-based Sorbents in Lake Water: Kinetics, Equilibrium, and Column Tests

    EPA Science Inventory

    Adsorption behavior of Bayoxide ® E33 (E33) and three E33-modified sorbents for the removal of phosphate from lake water was investigated in this study. E33-modified sorbents were synthesized by coating with manganese (E33/Mn) and silver (E33/AgI and E33/AgII) nanoparticles. Adso...

  4. Towards high peak capacity separations in normal pressure nanoflow liquid chromatography using meter long packed capillary columns.

    PubMed

    Han, Jing; Ye, Linquan; Xu, Lingjia; Zhou, Zhuoheng; Gao, Fan; Xiao, Zhiliang; Wang, Qiuquan; Zhang, Bo

    2014-12-10

    Single shot proteomics is a promising approach to high throughput proteomics analysis. In this strategy, long capillary columns are needed to perform long and shallow gradients to achieve high peak capacity and good peak width for informative mass spectrometric detection. Herein, we report that meter long capillary columns, packed with 5 μm particulate material, can be facilely fabricated based on single particle fritting technology. The long columns could reliably generate high peak capacities of 800 in 10 h long gradients for protein digest separations. The operation was within the pressure range (40 MPa) of the most widely used normal pressure nanoLC systems. Due to the excellent life time (>100 injections) and inter-column performance consistency, the meter long capillary columns reported here should be of practical usefulness in single shot proteomics without the need for ultra-high pressure instrumentation. PMID:25441907

  5. Conventional and enantioselective gas chromatography with microfabricated planar columns for analysis of real-world samples of plant volatile fraction.

    PubMed

    Cagliero, C; Galli, S; Galli, M; Elmi, I; Belluce, M; Zampolli, S; Sgorbini, B; Rubiolo, P; Bicchi, C

    2016-01-15

    Within a project exploring the application of lab-on-chip GC to in-field analysis of the plant volatile fraction, this study evaluated the performance of a set of planar columns (also known as microchannels, MEMS columns, or microfabricated columns) of different dimensions installed in a conventional GC unit. Circular double-spiral-shaped-channel planar columns with different square/rectangular sections up to 2m long were applied to the analysis of both essential oils and headspace samples of a group of medicinal and aromatic plants (chamomile, peppermint, sage, rosemary, lavender and bergamot) and of standard mixtures of related compounds; the results were compared to those obtained with reference narrow-bore columns (l:5m, dc:0.1mm, df:0.1 μm). The above essential oils and headspaces were first analyzed quali-and quantitatively with planar columns statically coated with conventional stationary phases (5%-phenyl-polymethylsiloxane and auto-bondable nitroterephthalic-acid-modified polyethylene glycol), and then submitted to chiral recognition of their diagnostic markers, by enantioselective GC with a planar columns coated with a cyclodextrin derivative (30% 6(I-VII)-O-TBDMS-3(I-VII)-O-ethyl-2(I-VII)-O-ethyl-β-cyclodextrin in PS-086). Column characteristics and analysis conditions were first optimized to obtain suitable retention and efficiency for the samples investigated. The planar columns tested showed performances close to the reference conventional narrow-bore columns, with theoretical plate numbers per meter (N/m) ranging from 6100 to 7200 for those coated with the conventional stationary phases, and above 5600 for those with the chiral selector. PMID:26733393

  6. Batch and column studies of adsorption of Li, Ni and Br by a reference sand for contaminant transport experiments

    SciTech Connect

    Seigel, M.D.; Ward, D.B.; Bryan, C.R.

    1995-09-01

    A processed quartz sand (Wedron 510), mined from the St. Peter sandstone, has been characterized by a variety of chemical and physical methods for use as a reference porous media in transport model validation experiments. Wedron 510 sand was used in an intermediate-scale experiment involving migration of Ni, Li and Br through a 6-m high x 3-m diameter caisson. Ni and Li adsorption/desorption, and Li/Ni site-competition experiments yielded information on the importance of the trace mineral phases to adsorption of Li and Ni by the sand. The presence of an iron hydroxide coating similar to goethite on the sand grains is suggested by visual observation and leaching experiments. Kaolinite was identified by SEM and XRD as a significant trace mineral phase in the sand and occurs as small particles coating the sand grains. Quartz, the predominant constituent of the sand by weight, does not appear to contribute significantly to the adsorption properties of the sand. Qualitatively, the adsorption properties of the sand can be adequately modeled as a two-mineral system (goethite and kaolinite). The studies described in this report should provide a basis for understanding transport of Ni, Li and Br through porous media similar to the reference sand. Techniques were developed for obtaining parameter values for surface complexation and kinetic adsorption models for the sand and its mineral components. These constants can be used directly in coupled hydrogeochemical transport codes. The techniques should be useful for characterization of other natural materials and elements in high-level nuclear waste in support of coupled hydrogeochemical transport calculations for Yucca Mountain.

  7. Purification of Single-Stranded cDNA Based on RNA Degradation Treatment and Adsorption Chromatography.

    PubMed

    Trujillo-Esquivel, Elías; Franco, Bernardo; Flores-Martínez, Alberto; Ponce-Noyola, Patricia; Mora-Montes, Héctor M

    2016-08-01

    Analysis of gene expression is a common research tool to study networks controlling gene expression, the role of genes with unknown function, and environmentally induced responses of organisms. Most of the analytical tools used to analyze gene expression rely on accurate cDNA synthesis and quantification to obtain reproducible and quantifiable results. Thus far, most commercial kits for isolation and purification of cDNA target double-stranded molecules, which do not accurately represent the abundance of transcripts. In the present report, we provide a simple and fast method to purify single-stranded cDNA, exhibiting high purity and yield. This method is based on the treatment with RNase H and RNase A after cDNA synthesis, followed by separation in silica spin-columns and ethanol precipitation. In addition, our method avoids the use of DNase I to eliminate genomic DNA from RNA preparations, which improves cDNA yield. As a case report, our method proved to be useful in the purification of single-stranded cDNA from the pathogenic fungus Sporothrix schenckii. PMID:27352216

  8. Streamlined pentafluorophenylpropyl column liquid chromatography-tandem quadrupole mass spectrometry and global 13C-labeled internal standards improve performance for quantitative metabolomics in bacteria

    PubMed Central

    Yang, Song; Sadilek, Martin; Lidstrom, Mary E.

    2010-01-01

    Streamlined quantitative metabolomics in central metabolism of bacteria would be greatly facilitated by a high-efficiency liquid chromatography (LC) method in conjunction with accurate quantitation. To achieve this goal, a methodology for LC-tandem quadrupole mass spectrometry (LC-MS/MS) involving a pentafluorophenylpropyl (PFPP) column and culture-derived global 13C-labeled internal standards (I.Ss.) has been developed and compared to hydrophilic interaction liquid chromatography (HILIC)-MS/MS and published combined two-dimensional gas chromatography and LC methods. All 50 tested metabolite standards from 5 classes (amino acids, carboxylic acids, nucleotides, acyl-CoAs and sugar phosphates) displayed good chromatographic separation and sensitivity on the PFPP column. In addition, many important critical pairs such as isomers / isobars (e.g. isoleucine / leucine, methylsuccinic acid / ethylmalonic acid and malonyl-CoA / 3-hydroxybutyryl-CoA) and metabolites of similar structure (e.g. malate / fumarate) were resolved better on the PFPP than on the HILIC column. Compared to only one 13C-labeled I.S., the addition of global 13C-labeled I.Ss. improved quantitative linearity and accuracy. PFPP-MS/MS with global 13C-labeled I.Ss. allowed the absolute quantitation of 42 metabolite pool sizes in M. extorquens AM1. A comparison of metabolite level changes published previously for ethylamine (C2) versus succinate (C4) cultures of Methylobacterium extorquens AM1 indicated a good consistency with the data obtained by PFPP-MS/MS, suggesting this single approach has the capability of providing comprehensive metabolite profiling similar to the combination of methods. The more accurate quantification obtained by this method forms a fundamental basis for flux measurements and can be used for metabolism modeling in bacteria in future studies. PMID:20950815

  9. Electron beam triggered, free radical polymerization-derived monolithic capillary columns for high-performance liquid chromatography.

    PubMed

    Schlemmer, Bettina; Bandari, Rajendar; Rosenkranz, Lutz; Buchmeiser, Michael R

    2009-03-27

    Monolithic capillary columns were prepared via electron beam triggered free radical polymerization within the confines of 0.2 and 0.1mm I.D. capillary columns using ethyl methacrylate and trimethylolpropane triacrylate as monomers as well as 2-propanol, 1-dodecanol and toluene as porogenic system. The influence of column diameter on reproducibility and separation performance was investigated. For evaluation, a protein standard consisting of five proteins in the range of 5800-66,000 g mol(-1) was used. Reproducibility was checked by determining the relative standard deviations in retention times, peak widths at half height, asymmetry and resolution. Excellent run-to-run reproducibility was found for both 0.2 and 0.1mm I.D. columns; batch-to-batch reproducibility was good for both column types. In order to enhance the non-polar character of the monolithic columns, lauryl methacrylate-based capillary columns were prepared. These were successfully used for the separation of proteins and a cytochrome c digest. PMID:18809181

  10. Isolation and identification of arctiin and arctigenin in leaves of burdock (Arctium lappa L.) by polyamide column chromatography in combination with HPLC-ESI/MS.

    PubMed

    Liu, Shiming; Chen, Kaoshan; Schliemann, Willibald; Strack, Dieter

    2005-01-01

    A simple method involving polyamide column chromatography in combination with HPLC-PAD and HPLC-ESI/MS for isolating and identifying two kinds of lignans, arctiin and arctigenin, in the leaves of burdock (Arctium lappa L.) has been established. After extraction of burdock leaves with 80% methanol, the aqueous phase of crude extracts was partitioned between water and chloroform and the aqueous phase was fractionated on a polyamide glass column. The fraction, eluting with 100% methanol, was concentrated and gave a white precipitate at 4 degrees C from which two main compounds were purified by semi-preparative HPLC. In comparison with the UV and ESI-MS spectra and the HPLC retention time of authentic standards, the compounds were determined to be arctiin and arctigenin. The extraction/separation technique was validated using an internal standard method. PMID:15881114

  11. Elution profile of di-peptides on a sulfonated ethylstyrene-divinylbenzene copolymer resin column by high-performance liquid chromatography.

    PubMed

    Guo, Jian; Saiki, Tomomi; Thanutchaporn, Kumrungsee; Liu, Wanying; Shimura, Akihiro; Matsui, Toshiro

    2015-01-01

    This study investigates the characteristics of a partially sulfonated ethylstyrene-divinylbenzene copolymer for the separation of di-peptides by high-performance liquid chromatography. Di-peptides (VE, VA, VH, VK, and VR) with different isoelectric points (pI, 4.0 to 9.7) and log P values (-1.63 to -0.72) were used to optimize the separation conditions of the columns packed with sulfonated copolymer resin. The retention factor (k) of the di-peptides on the column with a 0.81 wt% sulfo group content decreased with increasing concentrations of phosphate salts (2.5 - 20 mmol L(-1)) in the mobile phase. The complete separation of the five di-peptides was obtained with a gradient of 10% methanol containing 5 mmol L(-1) NaH2PO4 (pH 4.8) to 50% methanol containing 5 mmol L(-1) Na2HPO4 (pH 8.9) for 60 min at 0.5 mL min(-1) at 50°C. Under the optimal conditions, a good relationship between the k and pI values of the di-peptides, with the exception of VE (pI 4.0), was observed, suggesting that the retention of the di-peptides on the column packed with sulfonated copolymer resin was dependent on the pI value, when it was greater than 5. The log P value also influenced the separation characteristics of the column; peptides possessing the same pI value (6.4 for GH, VH, IH, and FH) showed a higher retention on the column with increasing log P values. In conclusion, the prototype sulfonated ethylstyrene-divinylbenzene copolymer column was applicable for the separation of basic di-peptides, and the separation depended on the pI and hydrophobicity of the di-peptides. PMID:25792273

  12. Simultaneous determination of bromate, chlorite and haloacetic acids by two-dimensional matrix elimination ion chromatography with coupled conventional and capillary columns.

    PubMed

    Teh, Hui Boon; Li, Sam Fong Yau

    2015-02-27

    A new, highly sensitive and reliable two-dimensional matrix elimination ion chromatography (IC) method was developed for simultaneous detection of bromate, chlorite and five haloacetic acids. This method combined the conventional IC in first dimension with capillary IC in the second dimension coupled with suppressed conductivity detection. The first dimension utilizes a high capacity column to partially resolve matrix from target analytes. By optimizing the cut window, the target analytes were selectively cut and trapped in a trap column through the use of a six-port valve, while the separated matrix were diverted to waste. The trapped target analytes were delivered on to the capillary column for further separation and detection. Temperature programming was used to improve selectivity in second dimension column to obtain complete resolution of the target analytes. Compared to the performance of one-dimensional IC, the two-dimensional approach resulted in a significant increase in sensitivity for all target analytes with limit of detection ranging from 0.30 to 0.64μg/L and provided more reliable analysis due to second column confirmation. Good linearity was obtained for all the target analytes with correlation coefficients >0.998. The proposed method was successfully applied to the determination of oxyhalides and haloacetic acids in various matrices with recoveries ranging from 90 to 116% and RSD less than 6.1%. The method allows direct injection of samples and the use of columns with different selectivity, thus significantly reduces the level of false positive results. The method is fully automated and simple, making it practical for routine monitoring of water quality. The satisfactory results also demonstrated that the two-dimensional matrix elimination method coupled with capillary IC is a promising approach for detection of trace substances in complex matrices. PMID:25650354

  13. New method for the determination of carbamate and pyrethroid insecticides in water samples using on-line SPE fused core column chromatography.

    PubMed

    Fernández-Ramos, C; Satínský, D; Solich, P

    2014-11-01

    A new HPLC column-switching method using large volume sample injection and fused-core columns for on-line solid phase extraction have been developed for the determination of the following carbamates and pyrethroids: aldicarb, carbaryl, pirimicarb, carbofuran, kadethrin, flumethrin, fenpropathrin, fenoxycarb, tau-fluvalinate and fenvalerate, in surface water samples. Sudan I was used as internal standard. The proposed method was performed using 100 µl sample injection followed by an on-line solid phase extraction procedure and finally the compounds were identified and quantified by liquid chromatography with ultraviolet detection. The separation was carried out on C-18 reversed phase column based on fused-core particle technology. The influence of the injected sample volume, the variables affecting to SPE process and the conditions for the separation on an analytical column, were studied and optimized. The limits of detection ranged from 5.5 to 8.9 µg L(-1), and limits of quantification from 18.4 to 29.7 µg L(-1), while inter- and intra-day variability was under 15%. This new analytical procedure was satisfactorily applied for the determination of these organic pollutants in surface water samples located in Czech Republic. Concentration levels were found for some of these pollutants up to 26.11 µg L(-1) in the river Elbe and up to 34.53 µg L(-1) in the closed lakes samples. PMID:25127636

  14. Development of a simple column-switching high-performance liquid chromatography (HPLC) method for rapid and simultaneous routine serum monitoring of lamotrigine, oxcarbazepine and 10-monohydroxycarbazepine (MHD).

    PubMed

    Greiner, Christine; Haen, Ekkehard

    2007-07-01

    Using isocratic column-switching high-performance liquid chromatography (HPLC) we established a group method for automated quantitative analysis of the antiepileptic drugs lamotrigine, oxcarbazepine and its metabolite 10-monohydroxycarbazepine (MHD) that are also used in psychiatry as mood stabilizers. Samples were cleaned from interfering proteins and lipids by transfer onto a pre-column, using a PerfectBond C-8 material, with 8% acetonitrile in water as a pre-column eluent. Separation was performed by elution onto the analytical column (Betasil C6 5 microm, 250 mm x 4.6 mm) at a flow rate of 1.0 ml/min with potassium dihydrogenphosphate buffer (20 mmol/l, pH3.0)/acetonitrile (70/30; v/v) as analytical eluent. UV-spectrophotometric detection was set to 215 nm for all three compounds. The analytical run was finished within 18 min. Detection limit was 30 ng/ml for lamotrigine, 35 ng/ml for oxcarbazepine and 25 ng/ml for 10-monohydroxycarbazepine. The method was found to be suitable for automated analysis of serum samples of patients treated with lamotrigine and oxcarbazepine. PMID:17478128

  15. Determination of benzalkonium chloride in eye care products by high-performance liquid chromatography and solid-phase extraction or on-line column switching.

    PubMed

    Elrod, L; Golich, T G; Morley, J A

    1992-11-20

    Benzalkonium chloride (BAK) is a mixture of alkylbenzyldimethylammonium chlorides, which is commonly used as a bacteriostat. In this work, the three major homologues of BAK are quantitated in the over-the-counter eye care products Murine and Murine Plus using high-performance liquid chromatography (HPLC). The analytes are separated from various product excipients and concentrated by either solid-phase extraction onto Sep-Pak C18 cartridges or by an on-line column-switching technique using 1-cm reversed-phase precolumns. Absolute recoveries of BAK homologues by the solid-phase extraction technique ranged from 97.2 to 98.7% for standards and from 98.0 to 98.4% for samples. Absolute recovery of the BAK homologues by the column-switching technique was 101.3% for standards and ranged from 99.9 to 103.7% for samples. Relative recoveries were quantitative by both techniques. Assay precision (R.S.D. values) were +/- 2.2% to +/- 2.6% and +/- 0.4% to +/- 0.8% by solid-phase extraction and column-switching techniques, respectively. The method provides advantages of high sample throughput, excellent column life and automation. PMID:1474126

  16. Chemometrics-assisted high performance liquid chromatography-diode array detection strategy to solve varying interfering patterns from different chromatographic columns and sample matrices for beverage analysis.

    PubMed

    Yin, Xiao-Li; Wu, Hai-Long; Gu, Hui-Wen; Hu, Yong; Wang, Li; Xia, Hui; Xiang, Shou-Xia; Yu, Ru-Qin

    2016-02-26

    This work reports a chemometrics-assisted high performance liquid chromatography-diode array detection (HPLC-DAD) strategy to solve varying interfering patterns from different chromatographic columns and sample matrices for the rapid simultaneous determination of six synthetic colorants in five kinds of beverages with little sample pretreatment. The investigation was performed using two types of LC columns under the same elution conditions. Although analytes using different columns have different co-elution patterns that appear more seriously in complex backgrounds, all colorants were properly resolved by alternating trilinear decomposition (ATLD) method and accurate chromatographic elution profiles, spectral profiles as well as relative concentrations were obtained. The results were confirmed by those obtained from traditional HPLC-UV method at a particular wavelength and the results of both methods were consistent with each other. All results demonstrated that the proposed chemometrics-assisted HPLC-DAD method is accurate, economical and universal, and can be promisingly applied to solve varying interfering patterns from different chromatographic columns and sample matrices for the analysis of complex food samples. PMID:26830638

  17. Systematic evaluation of commercially available ultra-high performance liquid chromatography columns for drug metabolite profiling: optimization of chromatographic peak capacity.

    PubMed

    Dubbelman, Anne-Charlotte; Cuyckens, Filip; Dillen, Lieve; Gross, Gerhard; Hankemeier, Thomas; Vreeken, Rob J

    2014-12-29

    The present study investigated the practical use of modern ultra-high performance liquid chromatography (UHPLC) separation techniques for drug metabolite profiling, aiming to develop a widely applicable, high-throughput, easy-to-use chromatographic method, with a high chromatographic resolution to accommodate simultaneous qualitative and quantitative analysis of small-molecule drugs and metabolites in biological matrices. To this end, first the UHPLC system volume and variance were evaluated. Then, a mixture of 17 drugs and various metabolites (molecular mass of 151-749Da, logP of -1.04 to 6.7), was injected on six sub-2μm particle columns. Five newest generation core shell technology columns were compared and tested against one column packed with porous particles. Two aqueous (pH 2.7 and 6.8) and two organic mobile phases were evaluated, first with the same flow and temperature and subsequently at each column's individual limit of temperature and pressure. The results demonstrated that pre-column dead volume had negligible influence on the peak capacity and shape. In contrast, a decrease in post-column volume of 57% resulted in a substantial (47%) increase in median peak capacity and significantly improved peak shape. When the various combinations of stationary and mobile phases were used at the same flow rate (0.5mL/min) and temperature (45°C), limited differences were observed between the median peak capacities, with a maximum of 26%. At higher flow though (up to 0.9mL/min), a maximum difference of almost 40% in median peak capacity was found between columns. The finally selected combination of solid-core particle column and mobile phase composition was chosen for its selectivity, peak capacity, wide applicability and peak shape. The developed method was applied to rat hepatocyte samples incubated with the drug buspirone and demonstrated to provide a similar chromatographic resolution, but a 6 times higher signal-to-noise ratio than a more traditional UHPLC

  18. Assessment of the selectivity equivalence of DB-608 and DB-624 open-tubular columns for gas chromatography.

    PubMed

    Kiridena, Waruna; Patchett, Cheryl C; Koziol, Wladyslaw W; Poole, Colin F

    2004-11-01

    The solvation parameter model is used to characterize the selectivity of DB-608 and DB-624 open-tubular columns at five equally spaced temperatures over the range 60 to 140 degrees C. The system constants for the DB-608 and DB-624 columns were used as selectivity parameters to search a database of open-tubular columns to identify columns with similar selectivity. The search was refined using the absolute deviation of the system constants and retention factor regression models for varied compounds. For method development it is shown that the selectivity of the poly(cyanopropylphenyldimethylsiloxane) stationary phase containing 6% cyanopropylphenylsiloxane monomer (DB-1301) is equivalent to DB-624 and the poly(dimethyldiphenylsiloxane) stationary phases containing either 50 or 65% diphenylsiloxane monomer (Rtx-50 and Rtx-65) are suitable choices for DB-608. PMID:15587283

  19. Selectivity differences between sol-gel coated and immobilized liquid film open-tubular columns for gas chromatography.

    PubMed

    Kiridena, Waruna; Poole, Colin F; Koziol, Wiadyslaw W

    2002-12-01

    The solvation parameter model is used to determine the system constants for two sol-gel coated open-tubular columns at five equally spaced temperatures in the range 60-140 degrees C. Differences in the system constants as a function of temperature are used to determine the affect of sol-gel structure on the selectivity of SolGel-l and SolGel-Wax columns compared with conventionally coated and immobilized poly(dimethylsiloxane) and poly(ethylene glycol) stationary phases. The sol-gel columns should be suitable for similar separations to those presently performed on conventional immobilized liquid film columns of the same type but selectivity differences for polar compounds, which depend on temperature, should be anticipated. PMID:12537368

  20. Enhancing detection sensitivity in gradient liquid chromatography via post-column refocusing and strong-solvent remobilization.

    PubMed

    De Vos, Jelle; Desmet, Gert; Eeltink, Sebastiaan

    2016-07-15

    We developed earlier the post-column refocusing strategy for isocratic separations, which employs trapping target analytes after an analytical separation and additionally focusing them using a strong remobilization solvent prior to detection, and have now extended it to high-speed gradient LC. A gradient separation of antibiotics and its metabolites, applying a linear aqueous acetonitrile gradient from 2 to 65% (v/v) ACN containing 0.1% FA in 10min, performed on an analytical column was selected as an application. Eluted heart-cut fractions were directed from the analytical silica C18 column to a trap column packed with Hypercarb particles. The remobilization of the target analytes was performed in back-flush mode using solvent mixtures tuned to maximize the solvent strength by mixing isopropanol into the remobilization solvent containing acetonitrile. Additionally, a viscosity-calibration experiment showed that the viscosity difference between trapping and remobilization solvents should be smaller than 0.15mPa·s to prevent viscous fingering. To keep the viscosity difference below this limit, during the gradient separation performed on the analytical column, the composition of the remobilization solvent was changed in time. An empirical equation is provided that allows for the selection of the optimal remobilization-solvent composition. To maximize the signal enhancement, the loading time of target analytes on the trap column should be optimized. Peak dispersion was further minimized by applying a flow rate that corresponded to the optimal van-Deemter flow rate of the trap column (20μL/min). Finally, decreasing the diameter of the trap column from 1mm to 0.3mm led to a significant enhancement of the detection sensitivity with more than one order of magnitude. Using an optimized trap configuration and elution/remobilization conditions, a signal enhancement of a factor of 14 was achieved for sulfaguanidine (early-eluting compound in the gradient separation) and 7

  1. Determination of tetracyclines in food samples by molecularly imprinted monolithic column coupling with high performance liquid chromatography.

    PubMed

    Sun, Xiangli; He, Xiwen; Zhang, Yukui; Chen, Langxing

    2009-08-15

    A novel solid phase extraction (SPE) method for determination of tetracyclines (TCs) in milk and honey samples by molecularly imprinted monolithic column was developed. Using tetracycline (TC) as the template, methacrylic acid (MAA) as the functional monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linker, methanol as the solvent, cyclohexanol and dodecanol as the mixed porogenic solvents, a TC imprinted monolithic column was prepared by in situ molecular imprinting technique for the first time, and the optimal synthesis conditions and the selectivity of TC imprinted monolithic column were investigated. The interfering substances in food samples and TCs can be separated successfully on imprinted column. Molecularly imprinted solid phase extraction (MISPE) coupling with C18 column was used to determinate the TCs in milk and honey. The recoveries of this method for six tetracyclines antibiotics such as tetracycline (TC), oxytetracycline (OTC), minocycline (MINO), chlortetracycline (CTC), metacycline (MTC) and doxycycline (DTC) were investigated, and high recoveries of 73.3-90.6% from milk samples and 62.6-82.3% from honey samples were obtained. A method for determination of TCs at low concentration level in milk and honey samples was successfully developed by using the monolithic column as the precolumn for solid phase extraction of six TCs compounds. PMID:19576466

  2. Determination of Gonyautoxin-4 in Echinoderms and Gastropod Matrices by Conversion to Neosaxitoxin Using 2-Mercaptoethanol and Post-Column Oxidation Liquid Chromatography with Fluorescence Detection

    PubMed Central

    Silva, Marisa; Rey, Verónica; Botana, Ana; Vasconcelos, Vitor; Botana, Luis

    2015-01-01

    Paralytic Shellfish Toxin blooms are common worldwide, which makes their monitoring crucial in the prevention of poisoning incidents. These toxins can be monitored by a variety of techniques, including mouse bioassay, receptor binding assay, and liquid chromatography with either mass spectrometric or pre- or post-column fluorescence detection. The post-column oxidation liquid chromatography with fluorescence detection method, used routinely in our laboratory, has been shown to be a reliable method for monitoring paralytic shellfish toxins in mussel, scallop, oyster and clam species. However, due to its high sensitivity to naturally fluorescent matrix interferences, when working with unconventional matrices, there may be problems in identifying toxins because of naturally fluorescent interferences that co-elute with the toxin peaks. This can lead to erroneous identification. In this study, in order to overcome this challenge in echinoderm and gastropod matrices, we optimized the conversion of Gonyautoxins 1 and 4 to Neosaxitoxin with 2-mercaptoethanol. We present a new and less time-consuming method with a good recovery (82.2%, RSD 1.1%, n = 3), requiring only a single reaction step. PMID:26729166

  3. Pre-column dilution large volume injection ultra-high performance liquid chromatography-tandem mass spectrometry for the analysis of multi-class pesticides in cabbages.

    PubMed

    Zhong, Qisheng; Shen, Lingling; Liu, Jiaqi; Yu, Dianbao; Li, Siming; Yao, Jinting; Zhan, Song; Huang, Taohong; Hashi, Yuki; Kawano, Shin-ichi; Liu, Zhaofeng; Zhou, Ting

    2016-04-15

    Pre-column dilution large volume injection (PD-LVI), a novel sample injection technique for reverse phase ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), was developed in this study. The PD-LVI UHPLC-MS/MS system was designed by slightly modifying the commercial UHPLC-MS/MS equipment with a mixer chamber. During the procedure of PD-LVI, sample solution of 200μL was directly carried by the organic mobile phase to the mixer and diluted with the aqueous mobile phase. After the mixture was introduced to the UHPLC column in a mobile phase of acetonitrile-water (15/85, v/v), the target analytes were stacked on the head of the column until following separation. Using QuEChERS extraction, no additional steps such as solvent evaporation or residue redissolution were needed before injection. The features of PD-LVI UHPLC-MS/MS system were systematically investigated, including the injection volume, the mixer volume, the precondition time and the gradient elution. The efficiency of this approach was demonstrated by direct analysis of 24 pesticides in cabbages. Under the optimized conditions, low limits of detection (0.00074-0.8 ng/kg) were obtained. The recoveries were in the range of 63.3-109% with relative standard deviations less than 8.1%. Compared with common UHPLC-MS/MS technique, PD-LVI UHPLC-MS/MS showed significant advantages such as excellent sensitivity and reliability. The mechanism of PD-LVI was demonstrated to be based on the column-head stacking effect with pre-column dilution. Based on the results, PD-LVI as a simple and effective sample injection technique of reverse phase UHPLC-MS/MS for the analysis of trace analytes in complex samples showed a great promising prospect. PMID:26979268

  4. Preparation of hybrid monolithic columns via "one-pot" photoinitiated thiol-acrylate polymerization for retention-independent performance in capillary liquid chromatography.

    PubMed

    Zhang, Haiyang; Ou, Junjie; Liu, Zhongshan; Wang, Hongwei; Wei, Yinmao; Zou, Hanfa

    2015-09-01

    A novel "one-pot" approach was developed for ultrarapid preparation of various hybrid monolithic columns in UV-transparent fused-silica capillaries via photoinitiated thiol-acrylate polymerization of an acrylopropyl polyhedral oligomertic silsesquioxane (acryl-POSS) and a monothiol monomer (1-octadecanethiol or sodium 3-mercapto-1-propanesulfonate) within 5 min, in which the acrylate not only homopolymerizes, but also couples with the thiol. This unique combination of two types of free-radical reaction mechanisms offers a simple way to fabricate various acrylate-based hybrid monoliths. The physical characterization, including scanning electron microscopy (SEM), Fourier transform infrared (FT-IR) spectroscopy, and thermal gravimetric analysis was performed. The results indicated that the monothiol monomers were successfully incorporated into acryl-POSS-based hybrid monoliths. The column efficiencies for alkylbenzenes on the C18-functionalized hybrid monolithic column reached to 60 000-73 500 plates/m at the velocity of 0.33 mm/s in capillary liquid chromatography, which was far higher than that of previously reported POSS-based columns prepared via thermal-initiated free-radical polymerization without adding any thiol monomers. By plotting the plate height (H) of the alkylbenzenes versus the linear velocity (u) of the mobile phase, the results revealed a retention-independent efficient performance of small molecules in the isocratic elution. These results indicated that more homogeneous hybrid monoliths formed via photoinitiated thiol-acrylate polymerization; particularly, the use of the multifunctional cross-linker possibly prevented the generation of gel-like micropores, reducing mass transfer resistance (C-term). Another sulfonate-containing hybrid monolithic column also exhibited hydrophobicity and ion-exchange mechanism, and the dynamic binding capacity was calculated as 71.1 ng/cm (75 μm i.d.). PMID:26223285

  5. Parallel dual secondary column-dual detection: a further way of enhancing the informative potential of two-dimensional comprehensive gas chromatography.

    PubMed

    Nicolotti, Luca; Cordero, Chiara; Bressanello, Davide; Cagliero, Cecilia; Liberto, Erica; Magagna, Federico; Rubiolo, Patrizia; Sgorbini, Barbara; Bicchi, Carlo

    2014-09-19

    Comprehensive two-dimensional gas chromatography (GC×GC) coupled with Mass Spectrometry (MS) is one of today's most powerful analytical platforms for detailed analysis of medium-to-high complexity samples. The column set usually consists of a long, conventional-inner-diameter first dimension ((1)D) (typically 15-30m long, 0.32-0.25mm dc), and a short, narrow-bore second dimension ((2)D) column (typically 0.5-2m, 0.1mm dc) where separation is run in a few seconds. However, when thermal modulation is used, since the columns of a set are coupled in series, a flow mismatch occurs between the two dimensions, making it impossible to operate simultaneously at optimized flow conditions. Further, short narrow-bore capillaries can easily be overloaded, because of their lower loadability, limiting the effectiveness of (2)D separation. In this study, improved gas linear velocities in both chromatographic dimensions were achieved by coupling the (1)D column with two parallel (2)D columns, having identical inner diameter, stationary phase chemistry, and film thickness. In turn, these were connected to two detectors: a fast quadrupole Mass Spectrometer (MS) and a Flame Ionization Detector (FID). Different configurations were tested and performances compared to a conventional set-up; experimental results on two model mixtures (n-alkanes and fourteen medium-to-high polarity volatiles of interest in the flavor and fragrance field) and on the essential oil of Artemisia umbelliformis Lam., show the system provides consistent results, in terms of analyte identification (reliability of spectra and MS matching) and quantitation, also affording an internal cross-validation of quantitation accuracy. PMID:25130094

  6. Numerical determination of non-Langmuirian adsorption isotherms of ibuprofen enantiomers on Chiralcel OD column using ultraviolet-circular dichroism dual detector.

    PubMed

    Li, Hui; Jiang, Xiaoxiao; Xu, Wei; Chen, Yongtao; Yu, Weifang; Xu, Jin

    2016-02-26

    Competitive adsorption isotherm of ibuprofen enantiomers on Chiralcel OD stationary phase at 298K was determined by the application of inverse method. Transport dispersive (TD) chromatography model was used to describe mass balances of the enatiomers. Axial dispersion and mass transfer coefficients were estimated from a series of linear pulse experiments. It was found that the overloaded elution profile of total concentration of racemic ibuprofen cannot be satisfactorily fitted by substituting bi-Langmuir model, the most widely used isotherm model for enantiomers, into TD model and tuning the isotherm parameters. UV-CD dual detector setup was then applied to obtain the individual overloaded elution profiles of both enantiomers. The more informative experimental data revealed non-Langmuirian adsorption behavior of ibuprofen enantiomers on chiralcel OD stationary phase. Two analytical binary isotherm models, both accounting for adsorbate-adsorbate interactions and having the feature of inflection points, were then evaluated. A comparison between quadratic model and Moreau model showed that the former gives better fitting results. The six parameters involved in quadratic model were determined stepwisely. Three of them were first obtained by fitting overloaded elution profiles of S-ibuprofen. The other three were then acquired by fitting overloaded elution profiles of both enantiomers recorded by UV-CD dual detector for racemic ibuprofen. A further attempt was also made at reducing the number of quadratic model parameters. PMID:26846132

  7. Enhanced adsorption of cesium on PVA-alginate encapsulated Prussian blue-graphene oxide hydrogel beads in a fixed-bed column system.

    PubMed

    Jang, Jiseon; Lee, Dae Sung

    2016-10-01

    A continuous fixed-bed column study was performed using PVA-alginate encapsulated Prussian blue-graphene oxide (PB-GO) hydrogel beads as a novel adsorbent for the removal of cesium from aqueous solutions. The effects of different operating parameters, such as initial cesium concentration, pH, bed height, flow rate, and bead size, were investigated. The maximum adsorption capacity of the PB-GO hydrogel beads was 164.5mg/g at an initial cesium concentration of 5mM, bed height of 20cm, and flow rate of 0.83mL/min at pH 7. The Thomas, Adams-Bohart, and Yoon-Nelson models were applied to the experimental data to predict the breakthrough curves using non-linear regression. Although both the Thomas and Yoon-Nelson models showed good agreement with the experimental data, the Yoon-Nelson model was found to provide the best representation for cesium adsorption on the adsorbent, based on the χ(2) analysis. PMID:27372009

  8. Coupled-column liquid chromatography combined with postcolumn photochemical derivatization and fluorescence detection for the determination of herbicides in groundwater.

    PubMed

    Mughari, Ahmed R; Galera, María Martínez; Vázquez, Piedad Parrilla; Valverde, Rosario Santiago

    2007-03-01

    This study examines the application of coupled-column LC-photochemically induced fluorimetry-fluorescence detection (LC-LC-PIF-FD), demonstrating its potential for the quantitative and selective detection of six herbicides, including propanil and the phenylureas monuron, monolinuron, chlorotoluron, diuron and neburon in groundwater samples. An AQUASIL C18 50 x 4.6 mm(2) id column coupled to an AQUASIL C18 150 x 4.6 mm(2) id column for analyte clean-up and determination were used, respectively. A simple SPE with Cl8 cartridges was carried out, yielding average recoveries between 80 and 112% (n = 6) with RSDs between 0.5 and 9%. The LODs ranged from 0.0083 to 0.0833 microg/L in the groundwater samples. PMID:17461105

  9. Solid phase extraction of chromium(VI) from aqueous solutions by adsorption of its diphenylcarbazide complex on a mixed bed adsorbent (acid activated montmorillonite-silica gel) column.

    PubMed

    Rajesh, N; Mishra, Braja Gopal; Pareek, Pawan Kumar

    2008-02-01

    A novel approach has been developed for the solid phase extraction of chromium(VI) based on the adsorption of its diphenylcarbazide complex on a mixture of acid activated montmorillonite (AAM)-silica gel column. The effect of various parameters such as acidity, stability of the column, sample volume, interfering ions, etc., were studied in detail. The adsorbed complex could be easily eluted using polyethylene glycol-sulfuric acid mixture and the concentration of chromium has been determined using visible spectrophotometry. The calibration graph was linear in the range 0-1microgmL(-1) chromium(VI) with a detection limit of 6microgL(-1). A highest preconcentration factor of 25 could be obtained for 250mL sample volume using glass wool as support for the mixed bed adsorbent. Chromium(VI) could be effectively separated from other ions such as nickel, copper, zinc, chloride, sulfate, nitrate, etc., and the method has been successfully applied to study the recovery of chromium in electroplating waste water and spiked water samples. PMID:17604681

  10. Solid phase extraction of chromium(VI) from aqueous solutions by adsorption of its diphenylcarbazide complex on a mixed bed adsorbent (acid activated montmorillonite-silica gel) column

    NASA Astrophysics Data System (ADS)

    Rajesh, N.; Mishra, Braja Gopal; Pareek, Pawan Kumar

    2008-02-01

    A novel approach has been developed for the solid phase extraction of chromium(VI) based on the adsorption of its diphenylcarbazide complex on a mixture of acid activated montmorillonite (AAM)-silica gel column. The effect of various parameters such as acidity, stability of the column, sample volume, interfering ions, etc., were studied in detail. The adsorbed complex could be easily eluted using polyethylene glycol-sulfuric acid mixture and the concentration of chromium has been determined using visible spectrophotometry. The calibration graph was linear in the range 0-1 μg mL -1 chromium(VI) with a detection limit of 6 μg L -1. A highest preconcentration factor of 25 could be obtained for 250 mL sample volume using glass wool as support for the mixed bed adsorbent. Chromium(VI) could be effectively separated from other ions such as nickel, copper, zinc, chloride, sulfate, nitrate, etc., and the method has been successfully applied to study the recovery of chromium in electroplating waste water and spiked water samples.

  11. Production and purification of human papillomavirus type 33 L1 virus-like particles from Spodoptera frugiperda 9 cells using two-step column chromatography.

    PubMed

    Baek, Jin-Oh; Seo, Jeong-Woo; Kim, Ik-Hwan; Kim, Chul Ho

    2011-02-01

    The major capsid protein L1 of human papillomavirus (HPV) is essential in construction of recombinant antigen vaccines against cervical cancer. HPV type 33 accounts for about 10% of all HPV infections in Asia. The gene encoding the major capsid protein L1 of the high-risk HPV type 33 was isolated from a Korean patient and expressed in Sf-9 insect cells using a baculovirus expression system. HPV33 L1 protein was isolated by two-step chromatographic purification using strong-cation exchange and ceramic hydroxyapatite chromatography. Strong-cation-exchange chromatography was performed to achieve initial purification of HPV33 L1 and to remove most contaminating proteins, and secondary ceramic hydroxyapatite chromatography yielded pure HPV33 L1 virus-like particles (VLPs). Ceramic hydroxyapatite columns are particularly useful in the purification of antibodies, antigens, human viruses, and VLPs, and we thus used this system. The expression of HPV L1 protein in Sf-9 cells was examined by SDS-PAGE, Western-blotting, and ELISA analyses, and the data showed that HPV33 L1 VLPs were determined to > 98% purity and 58.7% recovery by a quantitative immuno-ELISA assay. Transmission electron microscopy analysis revealed that the HPV VLPs were approximately 50-60 nm in diameter and created by self-assembly of HPV L1 protein. The efficient and simple purification process described here should be useful in production of a cervical cancer vaccine. PMID:20716445

  12. RAPID ANALYSIS OF CYNANURIC ACID IN SWIMMING POOL WATERS BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY USING POROUS GRAPHITIC CARBON COLUMN

    EPA Science Inventory

    An innovative approach is presented for reducing analysis times of cyanuric acid in swimming pool waters by high performance liquid chromatography (HPLC). The HPLC method exploits the unique selectivity of porous graphitic carbon (PGC) to fully resolve cyanuric acid from other p...

  13. Analysis of ethereal extracts of wines and other alcoholic beverages by high-performance liquid chromatography with microbore columns.

    PubMed

    Cartoni, G P; Coccioli, F; Spagnoli, M

    1997-10-10

    The ethereal extracts of wines, beer and vermouth were analysed by high-performance liquid chromatography. The following three characteristic peaks were first identified using GC-MS and then quantitatively determined: 5-hydroxy-methyl-2-furaldehyde, 2-(4-hydroxyphenyl)ethanol and 3-(2-hydroxyethyl)indole. PMID:9440923

  14. DETERMINATION OF VOLATILE ORGANIC COMPOUNDS IN SOILS USING EQUILIBRIUM HEADSPACE ANALYSIS AND CAPILLARY COLUMN GAS CHROMATOGRAPHY/MASS SPECTROMETRY

    EPA Science Inventory

    Existing methods for determination of volatile organic compounds (VOCs) in soil matrices using the purge and trap technique with gas chromatography/mass spectrometry (GC/MS) have several problems, which include preserving sample integrity from collection to analysis and efficient...

  15. Single column comprehensive analysis of pharmaceutical preparations using dual-injection mixed-mode (ion-exchange and reversed-phase) and hydrophilic interaction liquid chromatography.

    PubMed

    Kazarian, Artaches A; Taylor, Mark R; Haddad, Paul R; Nesterenko, Pavel N; Paull, Brett

    2013-12-01

    The comprehensive separation and detection of hydrophobic and hydrophilic active pharmaceutical ingredients (APIs), their counter-ions (organic, inorganic) and excipients, using a single mixed-mode chromatographic column, and a dual injection approach is presented. Using a mixed-mode Thermo Fisher Acclaim Trinity P1 column, APIs, their counter-ions and possible degradants were first separated using a combination of anion-exchange, cation-exchange and hydrophobic interactions, using a mobile phase consisting of a dual organic modifier/salt concentration gradient. A complementary method was also developed using the same column for the separation of hydrophilic bulk excipients, using hydrophilic interaction liquid chromatography (HILIC) under high organic solvent mobile phase conditions. These two methods were then combined within a single gradient run using dual sample injection, with the first injection at the start of the applied gradient (mixed-mode retention of solutes), followed by a second sample injection at the end of the gradient (HILIC retention of solutes). Detection using both ultraviolet absorbance and refractive index enabled the sensitive detection of APIs and UV-absorbing counter-ions, together with quantitative determination of bulk excipients. The developed approach was applied successfully to the analysis of a dry powder inhalers (Flixotide(®), Spiriva(®)), enabling comprehensive quantification of all APIs and excipients in the sample. PMID:24001905

  16. Rapid and simultaneous determination of tetrafluoroborate, thiocyanate and hexafluorophosphate by high-performance liquid chromatography using a monolithic column and direct conductivity detection.

    PubMed

    Yang, Ling; Yu, Hong; Wang, Yaqin

    2010-01-01

    A method was developed for fast and simultaneous determination of tetrafluoroborate (BF(4)(-)), thiocyanate (SCN(-)) and hexafluorophosphate (PF(6)(-)) by high-performance liquid chromatography using a silica-based monolithic column and direct (non-suppressed) conductivity detection. Chromatographic separation was performed on a Chromolith Speed ROD RP-18e column with tetrabutylammonium hydroxide (TBA) + citric acid + acetonitrile as eluent. The effects of the types of eluent, TBA concentration, acetonitrile volume fraction, eluent pH, column temperature and flow rate on the retention of anions were investigated. The optimized chromatographic conditions were selected. Under the optimal conditions, the baseline separation of BF(4)(-), SCN(-) and PF(6)(-) was achieved without any interference by other anions (F(-), Cl(-), Br(-), I(-), NO(3)(-), ClO(3)(-) and SO(4)(2-)). The detection limit (S/N = 3) was 0.42, 0.46 and 1.42 mg L(-1) for BF(4)(-), SCN(-) and PF(6)(-), respectively. The present method was successfully applied to the determination of BF(4)(-), SCN(-) and PF(6)(-) in ionic liquids. PMID:20702939

  17. Determination of diazepam and its metabolites in human urine by liquid chromatography/tandem mass spectrometry using a hydrophilic polymer column.

    PubMed

    Umezawa, Hironobu; Lee, Xiao-Pen; Arima, Yoshiko; Hasegawa, Chika; Marumo, Akemi; Kumazawa, Takeshi; Sato, Keizo

    2008-08-01

    Diazepam and its major metabolites, nordazepam, temazepam and oxazepam, in human urine samples, were analyzed by liquid chromatography (LC)/tandem mass spectrometry (MS/MS) using a hydrophilic polymer column (MSpak GF-310 4B), which enables direct injection of crude biological samples. Matrix compounds in urine were eluted first from the column, while the target compounds were retained on the polymer stationary phase. The analytes retained on the column were then eluted into an acetonitrile-rich mobile phase using a gradient separation technique. All compounds showed base-peak ions due to [M+H]+ ions on LC/MS with positive ion electrospray ionization, and product ions were produced from each [M+H]+ ion by LC/MS/MS. Quantification was performed by selected reaction monitoring. All compounds spiked into urine showed method recoveries of 50.1-82.0%. The regression equations for all compounds showed excellent linearity in the range of 0.5-500 ng/mL of urine. The limits of detection and quantification for each compound were 0.1 and 0.5 ng/mL of urine, respectively. The intra- and inter-day coefficients of variation for all compounds in urine were not greater than 9.6%. The data obtained from actual determination of diazepam and its three metabolites, oxazepam, nordazepam and temazepam, in human urine after oral administration of diazepam, are also presented. PMID:18618924

  18. Automated analysis of fluvoxamine in rat plasma using a column-switching system and ion-pair high-performance liquid chromatography.

    PubMed

    Liu, Shicheng; Shinkai, Norihiro; Kakubari, Ikuhiro; Saitoh, Hideo; Noguchi, Ken-ichi; Saitoh, Takashi; Yamauchi, Hitoshi

    2008-12-01

    We have established a robust, fully automated analytical method for the analysis of fluvoxamine in rat plasma using a column-switching ion-pair high-performance chromatography system. The plasma sample was injected onto a precolumn packed with Shim-pack MAYI-ODS (50 microm), where the drug was automatically purified and enriched by on-line solid-phase extraction. After elution of the plasma proteins, the analyte was back-flushed from the precolumn and then separated isocratically on a reversed-phase C18 column (L-column ODS) with a mobile phase (acetonitrile-0.1% phosphoric acid, 36:64, v/v) containing 2 mM sodium 1-octanesulfonate. The analyte was monitored by a UV detector at a wavelength of 254 nm. The calibration line for fluvoxamine showed good linearity in the range of 5-5000 ng/mL (r > 0.999) with the limit of quantification of 5 ng/mL (RSD = 6.51%). Accuracy ranged from -2.94 to 4.82%, and the within- and between-day precision of the assay was better than 8% across the calibration range. The analytical sensitivity and accuracy of this assay is suitable for characterization of the pharmacokinetics of orally-administered fluvoxamine in rats. PMID:18655223

  19. On-column entrapment of alpha1-acid glycoprotein for studies of drug-protein binding by high-performance affinity chromatography.

    PubMed

    Anguizola, Jeanethe; Bi, Cong; Koke, Michelle; Jackson, Abby; Hage, David S

    2016-08-01

    An on-column approach for protein entrapment was developed to immobilize alpha1-acid glycoprotein (AGP) for drug-protein binding studies based on high-performance affinity chromatography. Soluble AGP was physically entrapped by using microcolumns that contained hydrazide-activated porous silica and by employing mildly oxidized glycogen as a capping agent. Three on-column entrapment methods were evaluated and compared to a previous slurry-based entrapment method. The final selected method was used to prepare 1.0 cm × 2.1 mm I.D. affinity microcolumns that contained up to 21 (±4) μg AGP and that could be used over the course of more than 150 sample applications. Frontal analysis and zonal elution studies were performed on these affinity microcolumns to examine the binding of various drugs with the entrapped AGP. Site-selective competition studies were also conducted for these drugs. The results showed good agreement with previous observations for these drug-protein systems and with binding constants that have been reported in the literature. The entrapment method developed in this study should be useful for future work in the area of personalized medicine and in the high-throughput screening of drug interactions with AGP or other proteins. Graphical abstract On-column protein entrapment using a hydrazide-activated support and oxidized glycogen as a capping agent. PMID:27289464

  20. [Simultaneous determination of zeranols and chloramphenicol in foodstuffs of animal origin by combination immunoaffinity column clean-up and liquid chromatography-tandem mass spectrometry].

    PubMed

    Wang, Qing; Wang, Guomin; Xi, Cunxian; Li, Xianliang; Chen, Dongdong; Tang, Bobin; Zhang, Lei; Zhao, Hua

    2014-06-01

    A combination immunoaffinity column (IAC-CZ) clean-up and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analytical method was successfully developed for zearalenol, beta-zearalenol and zearalenone) and chloramphenicol (CAP) in foodstuffs of animal origin. The samples (fish, liver, milk and honey) were enzymatically digested by beta-glucuronidase/sulfatase for about 16 h and then extracted with ether. The extracts were evaporated to dryness and then the residues were dissolved by 1.0 mL of 50% acetonitrile solution. After filtered and diluted with PBS buffer, the reconstituted solution were cleaned-up with a IAC-CZ and then analyzed by LC-MS/MS in multiple reaction monitoring (MRM) mode. The chromatographic separation was performed on a Shimadzu Shim-pack VP-ODS column with gradient elution by acetonitrile and 2 mmol/L ammonium acetate solution. The detection was carried out by electrospray negative ionization mass spectrometry in MRM mode. The proposed method was validated by the limit of detection (0.04-0.10 microg/kg), linearity (R2 > or = 0.999 0), average recoveries (70.9%-95.6%) and precisions (2.0% - 11.8%). The developed method is reliable, sensitive and has good applicability. The combination immunoaffinity column was proved to be an effective pretreatment technique to decrease the matrix effect, and it met the requirements of residue analysis of co-occurring zeranols and chloramphenicol. PMID:25269264

  1. Adsorption performance of packed bed column for nitrate removal using PAN-oxime-nano Fe2O3

    PubMed Central

    2014-01-01

    A continuous fixed bed study was carried out by using PAN-oxime-nano Fe2O3 as a sorbent for the removal of nitrate from aqueous solution. The effect of factors, such as flow rate (2, 5 and 7 mL/min) and bed depth (5, 10 and 15 cm) were studied. Data confirmed that the breakthrough curves were dependent on flow rate and bed depth. The adsoption capacities observed in diffent conditions of flow rates (2,5 and 7 mL/min) were 11.65, 24.38 and 25.89, respectively. Thomas model was applied to experimental data to predict the breakthrough curves using linear regression and to determine the characteristic parameters of the packed bed column. Bed depth/service time analysis (BDST) model was used to investigate the effect of bed depth on breakthrough curves. The results showed that Thomas model was suitable for the normal description of breakthrough curve at the experimental condition. The data were in good agreement with BDST model with R2 > 0.98. Statistical analyses were performed on fluoride removal obtained from different flow rates using SPSS16 software by applying Kruskal- Wallis test. These findings suggested that PAN-oxime-nano Fe2O3 in the column structure presents a great potential in removal of nitrate from aqueous solutions. PMID:25045525

  2. Adsorption performance of packed bed column for nitrate removal using PAN-oxime-nano Fe2O3.

    PubMed

    Jahangiri-Rad, Mahsa; Jamshidi, Arsalan; Rafiee, Mohammad; Nabizadeh, Ramin

    2014-01-01

    A continuous fixed bed study was carried out by using PAN-oxime-nano Fe2O3 as a sorbent for the removal of nitrate from aqueous solution. The effect of factors, such as flow rate (2, 5 and 7 mL/min) and bed depth (5, 10 and 15 cm) were studied. Data confirmed that the breakthrough curves were dependent on flow rate and bed depth. The adsoption capacities observed in diffent conditions of flow rates (2,5 and 7 mL/min) were 11.65, 24.38 and 25.89, respectively. Thomas model was applied to experimental data to predict the breakthrough curves using linear regression and to determine the characteristic parameters of the packed bed column. Bed depth/service time analysis (BDST) model was used to investigate the effect of bed depth on breakthrough curves. The results showed that Thomas model was suitable for the normal description of breakthrough curve at the experimental condition. The data were in good agreement with BDST model with R(2) > 0.98. Statistical analyses were performed on fluoride removal obtained from different flow rates using SPSS16 software by applying Kruskal- Wallis test. These findings suggested that PAN-oxime-nano Fe2O3 in the column structure presents a great potential in removal of nitrate from aqueous solutions. PMID:25045525

  3. Dynamics of capillary electrochromatography. II. Comparison of column efficiency parameters in microscale high-performance liquid chromatography and capillary electrochromatography.

    PubMed

    Wen, E; Asiaie, R; Horváth, C

    1999-09-10

    In capillary electrochromatography (CEC) the flow of the mobile phase is generated by electrosmotic means in high electric field. This work compares band spreading measured experimentally in several packed capillaries with electrosmotic flow (EOF) and viscous flow under otherwise identical conditions. The data were fitted to the simplified van Deemter equation for the theoretical plate height, H = A + B/u + Cu, in order to evaluate parameters A and C in each mode of flow in the different columns. The ratio of these two parameters obtained with the same column in microscale HPLC (mu-HPLC) and CEC was used to quantify the attenuation of their contribution to band spreading upon changing from viscous flow (in mu-HPLC) to electrosmotic flow (in CEC). The capillary columns used in this study were packed with stationary phases of different pore sizes as well as retentive properties and measurements were carried out under different mobile phase conditions to examine the effects of the retention factor and buffer concentration. In the CEC mode, the value of both column parameters A and C was invariably by a factor of two to four lower than in the mu-HPLC mode. This effect may be attributed to the peculiarities of the EOF flow profile in the interstitial space and to the generation of intraparticle EOF inside the porous particles of the column packing. Thus, band spreading due to flow maldistribution and mass transfer resistances is significantly lower when the mobile phase flow is driven by voltage as in CEC, rather than by pressure as in mu-HPLC. PMID:10519080

  4. Separation of 2,3-butylene glycol and acetoin in fermented cheese whey permeate by liquid column chromatography

    SciTech Connect

    Lippi, M.S.

    1987-01-01

    While use of 2,3-butylene glycol could relieve pressure on consumption of petroleum-derived feedstocks, the economics of producing 2,3-butylene glycol by fermentation are still cost prohibitive. One of the main reasons for this is the high cost of recovering the 2,3-butylene glycol from the aqueous fermentation broth. The research presented here involves utilizing a low cost liquid column chromatographic operation for separating 2,3-butylene glycol and acetoin (another major by-product of the fermentation), in fermented cheese whey permeate. The procedure involves prewashing the column with an inexpensive solvent (aqueous sodium borate solution), and eluting samples with distilled and deionized water. Plain tap water was also shown to work equally well as the eluent. Separating 2,3-butylene glycol into the water eluent should improve the economics of the recovery process. The lower boiling water can be evaporated and distilled leaving the high boiling 2,3-butylene glycol (boiling point of 183 C). Steam generation and equipment specifications would be reduced thereby decreasing both capital and maintenance expenditures. Studies were performed and parameters were optimized on a laboratory scale and then scaled-up. Best results on the lab-scale was that a 54 ml separation was obtained from a 100 ml sample of the two compounds on a column 15 cm by 2.6 cm. Best results on the larger column showed that a one liter sample of ultrafiltered fermented cheese whey permeate containing 900 micrograms/ml of 2,3-butylene glycol and 300 micrograms/ml of acetoin was completely separated on a 20 cm by 11.4 cm column bed of Dowex 1-X8 anion-exchange resin.

  5. Adsorbents and columns in analytical high-performance liquid chromatography: a perspective with regard to development and understanding.

    PubMed

    Unger, Klaus K; Liapis, Athanasios I

    2012-06-01

    A brief historical survey is presented on the evaluation of silica adsorbents in analytical HPLC. The theory of analytical HPLC is mostly still being based on the height equivalent to a theoretical plate concept and the van Deemter equation that was derived from gas phase adsorption involving a linear adsorption isotherm and fast mass transfer kinetics. One can obviously wonder whether the use of the van Deemter equation is relevant and valid for the evaluation of the performance of HPLC systems, where most often the liquid solutes involve charged molecules in electrolytes and in very many cases the adsorbates are macromolecules having diffusion coefficients of small magnitude. Instead of the van Deemter equation, a multi-scale modelling approach that involves microscopic and macroscopic dynamic non-linear mass-transfer-rate models should be employed. Furthermore, advanced experimental methods for the characterisation of porous media and the distribution of the density of immobilised active sites (e.g., ligands) on surfaces as well as microscopic pore-network modelling and molecular dynamics modelling and simulation methods could be used for the design of novel adsorbents whose porous structures and immobilised active sites would provide effective mass transport and adsorption rates for realising efficient separations as well as high dynamic capacities when larger throughputs are required. PMID:22555863

  6. Programmed temperature vaporizing injector to filter off disturbing high boiling and involatile material for on-line high performance liquid chromatography gas chromatography with on-column transfer.

    PubMed

    Biedermann, Maurus; Grob, Koni

    2013-03-15

    Insertion of a programmed temperature vaporizing (PTV) injector under conditions of concurrent solvent recondensation (CSR) into the on-line HPLC-GC interface for on-column transfer (such as the retention gap technique with partially concurrent eluent evaporation) enables filtering off high boiling or involatile sample constituents by a desorption temperature adjusted to the required cut-off. Details of this technique were investigated and optimized. Memory effects, observed when transferred liquid was sucked backwards between the transfer line and the wall of the injector liner, can be kept low by a small purge flow rate through the transfer line at the end of the transfer and the release of the liquid through a narrow bore capillary kept away from the liner wall. The column entrance should be within the well heated zone of the injector to prevent losses of solute material retained on the liner wall during the splitless period. The desorption temperature must be maintained until an elevated oven temperature is reached to prevent peak broadening resulting of a cool inlet section in the bottom part of the injector. PMID:23394744

  7. Fast speciation of mercury in seawater by short-column high-performance liquid chromatography hyphenated to inductively coupled plasma spectrometry after on-line cation exchange column preconcentration.

    PubMed

    Jia, Xiao-Yu; Gong, Di-Rong; Han, Yi; Wei, Chao; Duan, Tai-Cheng; Chen, Hang-Ting

    2012-01-15

    A simple and fast method for trace speciation analysis of mercury (Hg(2+)), methylmercury (MeHg(+)) and ethylmercury (EtHg(+)) in seawater has been developed by short-column high-performance liquid chromatography hyphenated to inductively coupled plasma spectrometry (HPLC-ICP-MS) after on-line cation-exchange column (CEC) preconcentration. The analytes were firstly adsorbed on the CEC without any extraneous reagent, and then were eluted rapidly (within seconds) and completely with a very low concentration of l-cysteine solution, which provides the conveniency for the on-line coupling of the preconcentration method and detection technique. To our best knowledge, it is for the first time to employ the CEC preconcentration technique to trap all of the three mercury species simultaneously at their positive charged status for the purpose of speciation analysis. Under the optimized conditions, a very high preconcentration factor up to 1250 has been obtained with 30mL sample solution, which leads to the very low detection limits of 0.042ngL(-1) for Hg(2+), 0.016ngL(-1) for MeHg(+) and 0.008ngL(-1) for EtHg(+) (as Hg), respectively. With the established method, three seawater samples were also analyzed, and all the three mercury species have been found in each sample, albeit at a very low concentration. PMID:22265565

  8. Simultaneous determinations of Cr(VI) and Cr(III) by ion-exclusion/cation-exchange chromatography with an unmodified silica-gel column.

    PubMed

    Hirata, Shizuko; Kozaki, Daisuke; Sakanishi, Kinya; Nakagoshi, Nobukazu; Tanaka, Kazuhiko

    2010-01-01

    In order to characterize the ion-exclusion and cation-exchange properties of an unmodified silica-gel column, the retention behaviors of Cr(VI) and Cr(III) ions were investigated using a Develosil 30-5 (150 x 4.6 mm i.d.) in the acidic region. Cr(VI) was separated from other anions by an ion-exclusion and ion-adsorption mechanism, and Cr(III) was separated from other cations with a cation-exchange mechanism. When using 2.0 mM oxalic acid (pH 2.6) as an eluent, a good separation of Cr(VI) and Cr(III) was obtained using conductimetric detection in 12 min. The method was successfully applied to the simultaneous determinations of Cr(VI) and Cr(III) added into tap-water and river-water samples. PMID:20215693

  9. Quantitation of efletirizine in human plasma and urine using automated solid-phase extraction and column-switching high-performance liquid chromatography.

    PubMed

    Coe, R A; DeCesare, L S; Lee, J W

    1999-07-01

    A heart-cut column-switching, ion-pair, reversed-phase HPLC system was used for the quantitation of efletirizine (EFZ) in biological fluids. The analyte and an internal standard (I.S.) were extracted from human EDTA plasma by C18 solid-phase extraction (SPE) using a RapidTrace workstation. The eluent from the SPE was evaporated, reconstituted and injected onto the HPLC column. Urine samples were diluted and injected directly without the need of extraction. The compounds of interest were separated from most of the extraneous matrix materials by the first C18 column, and switched onto a second C18 column for further separation using a mobile phase of stronger eluting capability. Linearity range was 10-2000 ng ml(-1) for plasma and 0.05-10 microg ml(-1) for urine. The lower limit of quantitation (LOQ) was 10 ng from 1 ml of plasma, with a signal-to-noise ratio of 15:1. Inter-day precision and bias of quality control samples (QCs) were <5% for plasma and <7% for urine. Selectivity was established against six other antihistamines, three analogs of efletirizine, and on 12 control plasma lots and nine control urine lots. Recovery was 90.0% for EFZ and 89.5% for I.S. from plasma. One hundred samples can be processed in every 2.75 h on a 10-module RapidTrace workstation with minimal human attention. Method ruggedness were tested on three brands of SPE and six different lots of one SPE brand. Performance ruggedness was demonstrated by different analysts on multiple HPLC systems. Analyte stability through sample storage, extraction process (benchtop, freeze-thaw, refrigeration after extraction) and chromatography (on-system, reinjection) was established. PMID:10448959

  10. High-performance liquid chromatography with chemiluminescence detection of serum levels of pre-column derivatized fluoropyrimidine compounds.

    PubMed

    Yoshida, S; Urakami, K; Kito, M; Takeshima, S; Hirose, S

    1990-08-24

    7-(Diethylamino)-3-[4-[iodoacetyl)amino)phenyl]-4-methylcoumarin (DCIA) and 4-(bromomethyl)-7-methoxycoumarin have been evaluated as fluoropyrimidine-derivatizing agents to be detected using peroxyoxalate chemiluminescence with high-performance liquid chromatography. The derivatization procedure required only one step. No chemiluminescence was observed from the bromo derivatives, and the detection limits of fluoropyrimidine compounds derivatized with the iodo compound and detected with peroxyoxalate chemiluminescence were in the low femtomole range. PMID:2148941

  11. Optimization for speed and sensitivity in capillary high performance liquid chromatography. The importance of column diameter in online monitoring of serotonin by microdialysis.

    PubMed

    Zhang, Jing; Liu, Yansheng; Jaquins-Gerstl, Andrea; Shu, Zhan; Michael, Adrian C; Weber, Stephen G

    2012-08-17

    The speed of a separation defines the best time resolution possible in online measurements using chromatography. The desired time resolution multiplied by the flow rate of the stream of analyte being sampled defines the maximum volume of sample per injection. The best concentration sensitivity in chromatography is obtained by injecting the largest volume of sample that is consistent with achieving a satisfactory separation, and thus measurement accuracy. Taking these facts together, it is easy to understand that separation speed and concentration sensitivity are linked in this type of measurement. To address the problem of how to achieve the best sensitivity and shortest measurement time simultaneously, we have combined recent approaches to the optimization of the separation itself with an analysis of method sensitivity. This analysis leads to the column diameter becoming an important parameter in the optimization process. We use these ideas in one particular problem presented by online microdialysis sampling/liquid chromatography/electrochemical detection for measuring concentrations of serotonin in the dialysate. In this case the problem becomes the optimization of conditions to yield maximum signal for a given sample volume under the highest speed conditions with a certain required number of theoretical plates. It turns out that the observed concentration sensitivity at an electrochemical detector can be regulated by temperature, particle size, injection volume/column diameter, and void time. The theory was successfully used for optimization of neurotransmitter serotonin measurement by capillary HPLC when sampling from a microdialysis flow stream. The final conditions are: 150 μm i.d., 3.1cm long columns with 1.7 μm particle diameter working at a flow rate of 12 μL/min, an injection volume of 500 nL, and a temperature of 343 K. The retention time for serotonin is 22.7s, the analysis time is about 36 s (which allows for determination of 3-methoxytyramine), and

  12. Stage-frit: A straightforward sub-2 μm nano-liquid chromatography column fabrication for proteomic analysis.

    PubMed

    Hsieh, Ming-Yueh; Hsiao, He-Hsuan

    2015-07-30

    In this work we demonstrated a facile method for the fabrication of C18 coordination polymer gel in a capillary, called stage-frit, which was efficiently applied to pack sub-2 μm C18 beads into the capillary by a high pressure bomb for the online separation of proteolytic peptides. The back pressure of the column with 10 cm × 75 μm i.d. is regularly lower than 170 bar at a flow rate of 300 nl/min, which could be operated on a common nanoLC system instead of nanoUPLC system due to the good permeability, low back pressure and high mechanical stress of the frit that will totally reduce the cost for the purchase of instrument. The stage-frit allows long-term continuous flow of the solvent and no significant beads loss or pressure instability was observed during the period. The repeatability of retention time for fifteen BSA tryptic peaks was found to be less than 1.08% (RSD) in six time nanoLC-ESI-MS/MS experiments. The average full width at half maximum (FWHM) of peptide peaks is 5.87 s. The sub-2 μm stage-frit nanoLC column showed better sensitivity than the commercial available for large scale proteomic analysis of total tissue proteins from human spleen. The number of identified peptides is approximately 0.4-fold and 0.2-fold higher than that obtained by utilizing commercial columns packed with 3 μm and 1.8 μm C18 materials, respectively. In the field of analytical chemistry, particularly the use of nanoLC systems, stage-frit nanoLC column offers a great potential for the separation of complex mixtures. PMID:26320654

  13. Alignment of retention time obtained from multicapillary column gas chromatography used for VOC analysis with ion mobility spectrometry

    PubMed Central

    Bödeker, Bertram; Jünger, Melanie; Nolte, Jürgen; Vautz, Wolfgang

    2010-01-01

    Multicapillary column (MCC) ion mobility spectrometers (IMS) are increasingly in demand for medical diagnosis, biological applications and process control. In a MCC-IMS, volatile compounds are differentiated by specific retention time and ion mobility when rapid preseparation techniques are applied, e.g. for the analysis of complex and humid samples. Therefore, high accuracy in the determination of both parameters is required for reliable identification of the signals. The retention time in the MCC is the subject of the present investigation because, for such columns, small deviations in temperature and flow velocity may cause significant changes in retention time. Therefore, a universal correction procedure would be a helpful tool to increase the accuracy of the data obtained from a gas-chromatographic preseparation. Although the effect of the carrier gas flow velocity and temperature on retention time is not linear, it could be demonstrated that a linear alignment can compensate for the changes in retention time due to common minor deviations of both the carrier gas flow velocity and the column temperature around the MCC-IMS standard operation conditions. Therefore, an effective linear alignment procedure for the correction of those deviations has been developed from the analyses of defined gas mixtures under various experimental conditions. This procedure was then applied to data sets generated from real breath analyses obtained in clinical studies using different instruments at different measuring sites for validation. The variation in the retention time of known signals, especially for compounds with higher retention times, was significantly improved. The alignment of the retention time—an indispensable procedure to achieve a more precise identification of analytes—using the proposed method reduces the random error caused by small accidental deviations in column temperature and flow velocity significantly. PMID:20512565

  14. Immunoaffinity column coupled with liquid chromatography for determination of fumonisin B1 in canned and frozen sweet corn.

    PubMed

    Trucksess, M W; Stack, M E; Allen, S; Barrion, N

    1995-01-01

    A modified liquid chromatographic (LC) method for determining fumonisin B1 (FB1) in corn was applied to canned and frozen sweet corn. The corn is extracted with methanol-water (8 + 2), and the extract is filtered. The filtrate is diluted with water and passed through an immunoaffinity column. After the column is washed with water, FB1 is eluted with methanol-water (8 + 2). The eluate is evaporated to dryness by using a vacuum concentrator, and the residue is dissolved in acetonitrile-water (1 + 1). FB1 is derivatized with o-phthaldialdehyde. The derivative is separated on a reversed-phase C18 LC column using acetonitrile-water-acetic acid (50 + 50 + 1) and quantitated with a fluorescence detector. Recoveries of FB1 from canned and frozen corn spiked over the range of 50-200 ng/g were 76-88%. The limit of determination was about 25 ng/g, and the limit of detection was about 4 ng/g. The method was applied to 97 commercial canned and frozen sweet corn samples collected from different areas of the United States. Sixty samples contained no FB1. Low levels (trace-82 ng FB1/g corn) were found in 35 samples; 235 ng FB1/g was found in 1 canned corn sample, and 350 ng FB1/g was found in 1 frozen corn sample. PMID:7756885

  15. Aqueous size exclusion chromatography in semimicro and micro-columns by newly synthesized monodisperse macroporous hydrophilic beads as a stationary phase.

    PubMed

    Gölgelioğlu, Ciğdem; Bayraktar, Aslıhan; Celebi, Bekir; Uğuzdoğan, Erdal; Tuncel, Ali

    2012-02-10

    A new class of monodisperse macroporous beads in the hydrophilic form were synthesized by seeded microsuspension copolymerization of two acrylic crosslinking agents, glycerol dimethacrylate (GDMA) and glycerol-1,3-diglycerolate diacrylate (GDGDA). The monodisperse porous poly(glycerol dimethacrylate-co-glycerol-1,3-diglycerolate diacrylate), poly(GDMA-co-GDGDA) beads were highly hydrophilic in nature due to hydroxyl functionality resulting from both crosslinking agents. The beads with different particle sizes between 4.5 and 6.7 μm and with different porous properties were obtained by changing the seed latex to monomer ratio. The bead size decreased, the average pore size increased and the specific surface area decreased with increasing seed latex to monomer ratio. Poly(GDMA-co-GDGDA) beads were slurry packed in microbore and semimicro-HPLC columns and successfully used as a stationary phase in aqueous size exclusion chromatography (SEC) mode in a micro-liquid chromatography system. The aqueous SEC runs were performed by using dextran standards in the molecular weight range of 1000-670,000 Da. SEC calibration curves exhibiting linearity in a wider range of molecular weight were obtained with the semi-micro and micro-HPLC columns packed with the poly(GDMA-co-GDGDA) beads synthesized with the seed latex to monomer ratios of 0.038 and 0.058 g/mL. The dextran standards could be eluted in an analysis time shorter than 2 min using micro or semi-micro columns packed with poly(GDMA-co-GDGDA) beads as stationary medium. These packings are suitable for molecular weight determination between 5×10(3) and 5×10(5) Da in the aqueous medium by using mobile phase flow rates in the range of 25-250 μL/min. The average molecular weight determinations of different water soluble polymers, an ionic polymer, poly(2-dimethylaminoethyl methacrylate), a zwitterionic polymer, poly([2-(methacryloyloxy)ethyl]dimethyl-(3-sulfopropyl)ammonium hydroxide), and a non-ionic polymer, poly

  16. Evaluation and comparison of the kinetic performance of ultra-high performance liquid chromatography and high-performance liquid chromatography columns in hydrophilic interaction and reversed-phase liquid chromatography conditions.

    PubMed

    Song, Huiying; Adams, Erwin; Desmet, Gert; Cabooter, Deirdre

    2014-11-21

    An intrinsic performance comparison is made of the reduction in analysis time that can be obtained when switching from HPLC to UHPLC column formats in HILIC and reversed-phase conditions. A detailed overview of the packing characteristics of both stationary phase types is given first. It is demonstrated that HILIC columns demonstrate higher external porosity values than their reversed-phase counterparts resulting in lower flow resistance values. Column total porosity values determined from the elution time of a small marker molecule are shown to depend strongly on the composition of the mobile phase. To omit errors that might arise from an over- or underestimation of the column void time, all plate height and kinetic plot data are therefore expressed as a function of the interstitial velocity. Although only a limited number of columns are evaluated in this study, it is shown that the column efficiency of the HILIC columns is lower than that of their reversed-phase counterparts, at least for the compounds evaluated here. Despite this lower efficiency, the kinetic performance of both stationary phase types is similar, due to the much lower viscosity of the mobile phases typically used in HILIC conditions. Finally, it is demonstrated that a similar, yet slightly larger reduction in analysis time can be obtained when switching from HPLC column formats to UHPLC formats in HILIC compared to reversed-phase conditions. PMID:25441074

  17. Separation of phthalate esters from bio-oil derived from rice husk by a basification-acidification process and column chromatography.

    PubMed

    Zeng, Fanxin; Liu, Wujun; Jiang, Hong; Yu, Han-Qing; Zeng, Raymond J; Guo, Qingxiang

    2011-01-01

    Solid precipitate containing phthalate esters was obtained from rice-husk-derived oil through a basification-acidification process. After separation by column chromatography, the solid precipitate was divided into two mono-component fractions, two bi-component fractions and a tetra-component fraction. The major compounds of the five fractions were all consisted of phthalate esters. Especially, phthalate esters accounted for a proportion higher than 80% in both Fractions I and II. The generation and precipitation mechanisms of phthalate esters were proposed. Phthalate esters were considered to be derived from a series of complicated chemical reactions of small molecules in the biomass pyrolysis process, and precipitated from bio-oil by catalytic hydrolysis and esterification. PMID:20884201

  18. Analysis of illicit drugs in human urine by micellar electrokinetic capillary chromatography with on-column fast scanning polychrome absorption detection.

    PubMed

    Wernly, P; Thormann, W

    1991-12-15

    Using micellar electrokinetic capillary chromatography (MECC) with a borate/phosphate buffer containing 75 mM SDS (pH 9.1), common drugs of abuse and/or their metabolites, including opioids, benzoylecgonine, amphetamines, and methaqualone, can easily be analyzed. After solid-phase extraction of 5 mL of urine, drug concentrations down to about 100 ng/mL can be unambiguously monitored with on-column multiwavelength detection. Peak assignment is achieved through comparison of retention times and absorption spectra of eluting peaks with those of computer-stored model runs. The effectiveness of the approach is demonstrated with data obtained from different patient urines which tested positively for one or several drugs using nonisotopic immunoassays. Results suggest that MECC of illicit drugs is a highly specific and sensitive instrumental approach suitable for confirmation testing following a positive response of a toxicological screening procedure. PMID:1789451

  19. Simultaneous multi-mycotoxin determination in nutmeg by ultrasound-assisted solid-liquid extraction and immunoaffinity column clean-up coupled with liquid chromatography and on-line post-column photochemical derivatization-fluorescence detection.

    PubMed

    Kong, Wei-Jun; Liu, Shu-Yu; Qiu, Feng; Xiao, Xiao-He; Yang, Mei-Hua

    2013-05-01

    A simple and sensitive analytical method based on ultrasound-assisted solid-liquid extraction and immunoaffinity column clean-up coupled with high performance liquid chromatography and on-line post-column photochemical derivatization-fluorescence detection (USLE-IAC-HPLC-PCD-FLD) has been developed for simultaneous multi-mycotoxin determination of aflatoxins B1, B2, G1, G2 (AFB1, AFB2, AFG1, AFG2) and ochratoxin A (OTA) in 13 edible and medicinal nutmeg samples marketed in China. AFs and OTA were extracted from nutmeg samples by ultrasonication using a methanol : water (80 : 20, v/v) solution, followed by an IAC clean-up step. Different USL extraction conditions, pre-processing ways for nutmeg sample and clean-up columns for mycotoxins, as well as HPLC-PCD-FLD parameters (mobile phase, column temperature, elution procedure, excitation and emission wavelengths) were optimized. This method, which was appraised for analyzing nutmeg samples, showed satisfactory results with reference to limits of detection (LODs) (from 0.02 to 0.25 μg kg(-1)), limits of quantification (LOQs) (from 0.06 to 0.8 μg kg(-1)), linear ranges (up to 30 ng mL(-1) for AFB1, AFG1 and OTA and 9 ng mL(-1) for AFB2 and AFG2), intra- and inter-day variability (all <2%) and average recoveries (from 79.6 to 90.8% for AFs and from 93.6 to 97.3% for OTA, respectively). The results of the application of developed method in nutmeg samples have elucidated that four samples were detected with contamination of AFs and one with OTA. AFB1 was the most frequently found mycotoxin in 30.8% of nutmeg samples at contamination levels of 0.73-16.31 μg kg(-1). At least two different mycotoxins were co-occurred in three samples, and three AFs were simultaneously detected in one sample. PMID:23486692

  20. Protein adsorption and transport in dextran-modified ion-exchange media. II. Intraparticle uptake and column breakthrough.

    PubMed

    Bowes, Brian D; Lenhoff, Abraham M

    2011-07-22

    Protein transport behavior was compared for the traditional SP Sepharose Fast Flow and the dextran-modified SP Sepharose XL and Capto S resins. Examination of the dynamic binding capacities (DBCs) revealed a fundamental difference in the balance between transport and equilibrium capacity limitations when comparing the two resin classes, as reflected by differences in the locations of the maximum DBCs as a function of salt. In order to quantitatively compare transport behavior, confocal microscopy and batch uptake experiments were used to obtain estimates of intraparticle protein diffusivities. For the traditional particle, such diffusivity estimates could be used to predict column breakthrough behavior accurately. However, for the dextran-modified media, neither the pore- nor the homogeneous-diffusion model was adequate, as experimental dynamic binding capacities were consistently lower than predicted. In examining the shapes of breakthrough curves, it was apparent that the model predictions failed to capture two features observed for the dextran-modified media, but never seen for the traditional resin. Comparison of estimated effective pore diffusivities from confocal microscopy and batch uptake experiments revealed a discrepancy that led to the hypothesis that protein uptake in the dextran-modified resins could occur with a shrinking-core-like sharp uptake front, but with incomplete saturation. The reason for the incomplete saturation is speculated to be that protein initially fills the dextran layer with inefficient packing, but can rearrange over time to accommodate more protein. A conceptual model was developed to account for the partial shrinking-core uptake to test whether the physical intuition led to predictions consistent with experimental behavior. The model could correctly reproduce the two unique features of the breakthrough curves and, in sample applications, parameters found from the fit of one breakthrough curve could be used to adequately match

  1. Monitoring of enzymatic hydrolysis of starch by microdialysis sampling coupled on-line to anion exchange chromatography and integrated pulsed electrochemical detection using post-column switching

    SciTech Connect

    Torto, N.; Gorton, L.; Emneus, J.; Laurell, T.; Marko-Varga, G.; Akerberg, C.; Zacchi, G. |

    1997-12-05

    A quantitative evaluation of the hydrolysis of wheat starch using Termamyl, a thermostable {alpha}-amylase, is reported. Data from the monitoring of the hydrolysis of wheat starch indicated that, after 1 h, glucose and maltooligosaccharides up to DP 7 were the main hydrolysis products and thus enabled optimization of a liquefaction step during the production of L-lactic acid. The monitoring system used, both in the on- and off-line mode, was based on continuous flow microdialysis sampling (CFMS) coupled to anion exchange chromatography and integrated pulsed electrochemical detection (IPED). A microdialysis probe equipped with a 5-mm polysulfone (SPS 4005) membrane, with a molecular-weight cut-off of 5 kDa, was used to sample the hydrolysis products of native wheat starch at 90 C. Characteristic fingerpoint separations were achieved by anion exchange chromatography after enzymatic hydrolysis. Post-column switching improved the detection and, consequently, also quantification of the hydrolysates as fouling of the electrode could be reduced. Maltooligosaccharide standards were used for quantification and to verify the elution of the hydrolysates by spiking the off-line samples.

  2. Robust method for the analysis of phytochelatins in rice by high-performance liquid chromatography coupled with electrospray tandem mass spectrometry based on polymeric column materials.

    PubMed

    Yu, Shasha; Bian, Yingfang; Zhou, Rong; Mou, Renxiang; Chen, Mingxue; Cao, Zhaoyun

    2015-12-01

    A sensitive and robust high-performance liquid chromatography coupled with electrospray tandem mass spectrometry method for the identification and quantification of glutathione and phytochelatins from rice was developed. Homogenized samples were extracted with water containing 100 mM dithiothreitol, and solid-phase extraction using polymer anion exchange resin was employed for sample purification. Chromatography was performed on a polymeric column with acetonitrile and water containing 0.1% formic acid as the mobile phase at the flow rate of 300 μL/min. The limit of quantitation was 6-100 nM. This assay showed excellent linearity for both glutathione and phytochelatins over physiological normal ranges, with correlation coefficients (r) > 0.9976. Recoveries for four biothiols were within the range of 76-118%, within relative standard deviations less than 15%. The intraday precision (n = 7) was 2.1-13.3%, and the interday precision over 15 days was 4.3-15.2%. The optimized method was applied to analyze tissue samples from rice grown using nutrient solutions with three different cadmium concentrations (0, 50, and 100 μM). With increasing cadmium concentrations, the content of phytochelatin 2 and phytochelatin 3 in rice roots increased, in contrast to most phytochelatins, and the content of glutathione in rice stems and roots decreased significantly. PMID:26541262

  3. High-throughput sample preparation and simultaneous column regeneration liquid chromatography-tandem mass spectrometry method for determination of nitrogen mustard metabolites in human urine.

    PubMed

    Reddy, Muntha K; Mills, Grier; Nixon, Christopher; Wyatt, Shane A; Croley, Timothy R

    2011-08-15

    Nitrogen mustards (NMs) are known to have DNA alkylation and strong vesicant properties. Their availability to terrorist organizations makes them a potential choice for chemical attacks on civilian populations. After an exposure, it is difficult to measure NMs directly because of their rapid metabolism in the human body. Therefore to determine an individual's level of exposure to NMs, it is necessary to analyze for NM metabolites being excreted by the body. The metabolites of NMs are generated by a hydrolysis reaction, and are easily detectable by liquid chromatography tandem mass spectrometry (LC-MS/MS). This work is focused on the development of a high-throughput assay for the quantitation of N-ethyldiethanolamine (EDEA) and N-methyldiethanolamine (MDEA) metabolites of bis (2-chloroethyl) ethylethanamine (HN1) and bis (2-chloroethyl) methylethanamine (HN2), respectively. The method uses automated 96-well plate sample preparation of human urine samples and a 2-position 10-port switching valve to allow for simultaneous regeneration of the liquid chromatography (LC) columns. Using this method, over 18 h was saved through the reduction of sample preparation and analysis time when compared to a conventional method for 96 samples. The validated method provided excellent accuracy for both EDEA (100.9%) and MDEA (100.6%) with precision better than 5.27% for each analyte. PMID:21764395

  4. Acaricidal activity of petroleum ether extract of neem (Azadirachta indica) oil and its four fractions separated by column chromatography against Sarcoptes scabiei var. cuniculi larvae in vitro.

    PubMed

    Deng, Yunxia; Shi, Dongxia; Yin, Zhongqiong; Guo, Jianhong; Jia, Renyong; Xu, Jiao; Song, Xu; Lv, Cheng; Fan, Qiaojia; Liang, Xiaoxia; Shi, Fei; Ye, Gang; Zhang, Wei

    2012-04-01

    The petroleum ether extract of neem oil and its four fractions separated by column chromatography was diluted at different concentrations with liquid paraffin. The acaricidal bioassay was conducted using a dipping method. The results indicated that the median lethal concentration (LC50) of the petroleum ether extract (at the concentration of 500.0ml/l) was 70.9ml/l, 24h after treatment. At concentrations of 500.0, 250.0, 125.0, 62.5 and 31.2ml/l, the median lethal times (LT50) of the petroleum ether extract were 8.7, 8.8, 10.8, 11.5 and 13.1h, respectively. Thin-layer chromatography (TLC) showed that the petroleum ether extract of neem oil separated into four fractions (F1-F4). Acaricidal activity of 68.3% and 100.0% in the F2 and F4 was confirmed. These results suggest that petroleum ether extracts of neem oil and its four fractions possess useful acaricidal activity in vitro. PMID:22349080

  5. Fast analysis of isoflavones by high-performance liquid chromatography using a column packed with fused-core particles.

    PubMed

    Manchón, N; D'Arrigo, M; García-Lafuente, A; Guillamón, E; Villares, A; Ramos, A; Martínez, J A; Rostagno, M A

    2010-10-15

    The recent development of fused-core technology in HPLC columns is enabling faster and highly efficient separations. This technology was evaluated for the development of an fast analysis method for the most relevant soy isoflavones. A step-by-step strategy was used to optimize temperature (25-50°C), flow rate (1.2-2.7 mL/min), mobile phase composition and equilibration time (1-5 min). Optimized conditions provided a method for the separation of all isoflavones in less than 5.8 min and total analysis time (sample-to-sample) of 11.5 min. Evaluation of chromatographic performance revealed excellent reproducibility, resolution, selectivity, peak symmetry and low limits of detection and quantification levels. The use of a fused-core column allows highly efficient, sensitive, accurate and reproducible determination of isoflavones with an outstanding sample throughout and resolution. The developed method was validated with different soy samples with a total isoflavone concentration ranging from 1941.53 to 2460.84 μg g(-1) with the predominant isoflavones being isoflavone glucosides and malonyl derivatives. PMID:20875606

  6. Separation and detection of ammonia, amines, and alkanolamines with single-column ion chromatography. [Alkylamines, ethanolamine and methyldiethanolamine

    SciTech Connect

    Poulson, R.E.; Borg, H.M.

    1986-03-01

    A single-column ion chromatographic method was developed for separation and detection of aqueous ammonia, C/sub 1/-, C/sub 2/-, and C/sub 3/- alkylamines, ethanolamine, and methyldiethanolamine. A precolumn concentrator was used to take detection of ammonium ion by electrical conductivity to fractional ppB levels and detection of the organic cations to ppB levels. Analysis of ppM ammonia levels in 3 wt % alkanolamine scrubber-type solutions was possible, but resolution of alkylamines was lost. A post-column reaction system for fluorescence detection of primary amine o-phthalaldehyde derivatives with reversed-phase separation allowed amine separation in the presence of large amounts of ammonia. The same system might be used in place of concentration and conductivity for determination of the alkylamine levels. A large variety of oil shale retort by-product waters and one underground coal gasification condensate were screened for alkylamines, but none were detected. 7 refs., 8 figs., 1 tab.

  7. Express analysis of explosives, chemical warfare agents and drugs with multicapillary column gas chromatography and ion mobility increment spectrometry.

    PubMed

    Buryakov, Igor A

    2004-02-01

    Description of a gas chromatograph designed for express analysis of explosives (2,4-dinitrotoluene, 2,4,6-trinitrotoluene, pentaerythritol tetranitrate), chemical warfare agents (mustard gas, lewisite, sarin) and drugs (heroin, cocaine hydrochloride, crack) is given. The devices comprises a multicapillary chromatographic column and an ion mobility increment spectrometer (MCC-IMIS). The main analytical characteristics of an IMIS (estimated detection limit (DL), linear dynamic range (LDR), speed of response) and a chromatographic column (separation power, degree of separation, a number of possible peaks at a chromatogram section, divided by analysis time) are determined. The maximum value of DL equal to 5 pg/ml was registered for cis-alpha-LW, and the lowest one of 0.001 pg/ml was for cocaine. The maximum value of LDR equal to 1000 was registered for sarin and the lowest one of 150 was for the ions of lewisite. Speed of response of one compound detection with the IMIS was 0.7 s. PMID:14698239

  8. Measuring Ochratoxin A Concentrations in Coffee Beverages with Immunoaffinity Columns and Ultra-Performance Liquid Chromatography/Tandem Mass Spectrometry.

    PubMed

    Chen, Wen-Ling; Chang, Chiung-Wen; Chen, Chia-Yang

    2016-01-01

    This study developed and validated a method for measuring concentrations of ochratoxin A (OTA) in coffee beverages, not coffee beans. The new method involved extraction using immunoaffinity columns and ultra-performance LC (UPLC)-MS/MS using isotope-dilution techniques. The combination of a fused-core column and UPLC significantly shortened chromatographic time to 3 min compared to reported UPLC methods. The method was sensitive, with an LOD and LOQ of 0.52 and 1.73 pg/mL, respectively. Quantitative intraday (n = 4) and interday (n = 4) biases and RSD were both below 15%. The OTA levels in 40 samples of freshly brewed coffee from chain stores, 24 samples of canned ready-to-drink coffee, and 6 beverages made from instant coffee granules ranged from 1.60 to 93.2 pg/mL (90% positive), 6.00 to 131 pg/mL (100% positive), and 21.8 to 59.0 pg/mL (100% positive), respectively. Based on published tolerable daily intake, men and women in Taiwan should consume no more than 6.3 and 5.1 fifteen gram packages of instant coffee per day, respectively. Specific suggestions were not made for brewed coffee and canned coffee because of their large variation in OTA concentrations. This study should be more relevant to actual human exposure than those studying OTA in green, roasted, and ground coffee beans alone. PMID:26965577

  9. Monolithic metal-organic framework MIL-53(Al)-polymethacrylate composite column for the reversed-phase capillary liquid chromatography separation of small aromatics.

    PubMed

    Yusuf, Kareem; Badjah-Hadj-Ahmed, Ahmed Yacine; Aqel, Ahmad; ALOthman, Zeid Abdullah

    2016-03-01

    A monolithic capillary column containing a composite of metal-organic framework MIL-53(Al) incorporated into hexyl methacrylate-co-ethylene dimethacrylate was prepared to enhance the separation of mixtures of small aromatic compounds by using capillary liquid chromatography. The addition of 10 mg/mL MIL-53(Al) microparticles increased the micropore content in the monolithic matrix and increased the Brunauer-Emmett-Teller surface area from 26.92 to 85.12 m(2) /g. The presence of 1,4-benzenedicarboxylate moieties within the structure of MIL-53(Al) as an organic linker greatly influenced the separation of aromatic mixtures through π-π interactions. High-resolution separation was obtained for a series of alkylbenzenes (with resolution factors in the range 0.96-1.75) in less than 8 min, with 14 710 plates/m efficiency for propylbenzene, using a binary polar mobile phase of water/acetonitrile in isocratic mode. A reversed-phase separation mechanism was indicated by the increased retention factor and resolution as the water percentage in the mobile phase increased. A stability study on the composite column showed excellent mechanical stability under various conditions. The higher resolution and faster separation observed at increased temperature indicated an exothermic separation, whereas the negative values for the free energy change of transfer indicated a spontaneous process. PMID:26711438

  10. The analysis of beta-agonists by packed-column supercritical fluid chromatography with ultra-violet and atmospheric pressure chemical ionisation mass spectrometric detection.

    PubMed

    Jones, D C; Dost, K; Davidson, G; George, M W

    1999-06-01

    Packed-column supercritical fluid chromatography (pSFC) using ultra-violet (UV) and atmospheric pressure chemical ionisation (APCI) mass spectrometry (MS) provides a versatile method for the identification and quantification of beta-agonists. We have achieved good separation of clenbuterol, salbutamol, terbutaline and fenoterol with good resolution and reasonable retention times using a high concentration of methanol modifier in the supercritical CO2, together with small amounts of both acidic (trifluoroacetic acid, TFAA) and basic (triethylamine, TEA, or diethylamine, DEA) additives. APCI-MS gave unambiguous identification of the 4 analytes, and increasing cone voltage provided informative fragmentation patterns. The pSFC-MS technique was shown to be linear (R2 > or = 0.996) over the concentration range 1-50 micrograms ml-1. Single ion monitoring (SIM) gave detection limits (on-column) of 2.5 ng (clenbuterol), 0.83 ng (terbutaline), 7.6 ng (salbutamol) and 2.7 ng (fenoterol). The pSFC-MS system was shown to be reproducible within a day, between days, and between restrictors. Analysis of milk samples 'spiked' with beta-agonists showed that the matrix caused no interference, with detection limits of approximately 500 micrograms l-1 of beta-agonists. More dilute solutions could be analysed by pre-concentration before the SFC stage. PMID:10736867

  11. Preparative isolation of alkaloids from Dactylicapnos scandens using pH-zone-refining counter-current chromatography by changing the length of the separation column.

    PubMed

    Wang, Xiao; Dong, Hongjing; Yang, Bin; Liu, Dahui; Duan, Wenjuan; Huang, Luqi

    2011-12-01

    pH-Zone-refining counter-current chromatography was successfully applied for the preparative separation of alkaloids from Dactylicapnos scandens. The two-phase solvent system was composed of petroleum ether-ethyl acetate-methanol-water (3:7:1:9, v/v), where 20 mM of triethylamine (TEA) was added to the upper phase as a retainer and 5 mM of hydrochloric acid (HCl) to the aqueous phase as an eluter. In this experiment, the apparatus with an adjustable length of the separation column was used for the separation of alkaloids from D. scandens and the resolution of the compounds can be remarkably improved by increasing the length of the separation column. As a result, 70 mg protopin, 30 mg (+) corydine, 120 mg (+) isocorydine and 40 mg (+) glaucine were obtained from 1.0 g of the crude extracts and each with 99.2%, 96.5%, 99.3%, 99.5% purity as determined by HPLC. The chemical structures of these compounds were confirmed by positive ESI-MS and (1)H NMR. PMID:22056347

  12. Elution behavior of short dsDNA strands in silicon micropillar array columns in ion pair reversed-phase chromatography mode.

    PubMed

    Zhang, Lei; Majeed, Bivragh; Lynen, Frederic; Van Hoof, Chris; De Malsche, Wim

    2012-11-01

    In the present paper, dsDNA separation has been studied in a silicon micropillar array column using ion-pair RP-HPLC (IP-RP-HPLC). The deep-etched (32.0 μm) silicon micropillar array was fabricated by advanced deep UV lithography and by a dedicated Bosch etch process and then sealed by anodic bonding to a Pyrex glass. The pillar surface was subsequently conditioned hydrophobic. Working in isocratic mode under nonretained conditions, van Deemter curves of dsDNA and coumarin were established to assess the performance of the micropillar array column, resulting in plate heights of only a few micrometers. Working in gradient mode, separations of dsDNA fragments were evaluated. The relevant gradient operation parameters were studied to understand their influence on dsDNA separations. The correlation between DNA length and retention was measured and theoretically described in a length range of 50-500 bp, promising for the determination of DNA of an unknown length. Finally, a separation example demonstrated the excellent separation power of on-chip IP-RP chromatography by achieving a large operation range of DNA length (10-300 bp) with a 5-bp difference among 11 dsDNA fragments. PMID:22949311

  13. Development of a high-performance liquid chromatography method based on a core-shell column approach for the rapid determination of multiclass polyphenols in grape pomaces.

    PubMed

    Fontana, Ariel R; Antoniolli, Andrea; Bottini, Rubén

    2016-02-01

    A rapid and economically affordable reverse-phase chromatographic approach based on a core-shell column with high-performance liquid chromatography multi-wavelength detector (HPLC-MWD) is proposed for the quantification and quality control of multiclass polyphenols (PPs). The separation of 20 relevant polyphenols from grape pomace extracts (GPEs) was achieved in less than 12 min by using a Kinetex C18 column (3.0 mm × 100 mm, 2.6 μm) with a gradient system of ultrapure water (0.1% formic acid) and acetonitrile, a temperature of 35 °C and a flow rate of 0.8 mL min(-1). The maximum backpressure reached was 327 bar, meaning the developed method is adequate for standard HPLC instruments. The applicability of the method was demonstrated by the determination of PPs in GPEs of different red grape varieties. Cabernet Sauvignon GPE showed the highest content of studied PPs (9804.2 μg g(-1)GPE) followed by Bonarda GPE (7302.0 μg g(-1)GPE). Besides the methodological development for a high throughput routine quality control of GPEs, this is the first report of PPs content for Bonarda and Aspirant Bouchet GPE, so the results add knowledge for these grape varieties cultivated in Argentina. PMID:26304313

  14. Determination of cobalt, nickel and iron at trace level in natural water samples by in-column chelation-reversed phase high-performance liquid chromatography.

    PubMed

    Hol, Aysen; Divrikli, Umit; Elci, Latif

    2012-06-01

    This paper reports the utilization of 4-(2-pyridylazo) resorcinol (PAR) as a chelating reagent for in-column derivatization and the determination of trace Co, Fe, and Ni ions by reversed-phase high-performance liquid chromatography with photodiode array detector. A good separation of Co, Fe, and Ni chelates were achieved by using an Inertsil ODS-3 column and a mobile phase, consisted of methanol-THF-water mixture (50:5:45) containing ammonium acetate buffer (pH 5.0) and PAR. After full optimization, good repeatability of retention times (relative standard deviation (RSD) < 0.05%) and peak areas (RSD < 1.7%) was achieved as well as a good linearity (r (2) > 0.9991). The detection limits (S/N = 3), expressed as micrograms per liter, were 0.50 (Co), 9.07 (Fe), and 2.00 (Ni). The applicability and the accuracy of the developed method were estimated by the analysis of spiked water samples and certified reference material BCR 715 wastewater-SRM. PMID:21701886

  15. [Analysis of rice leaves proteomes by liquid chromatography-tandem, mass spectrometry based on the purification using a novel affinity detergent removal spin column].

    PubMed

    Cao, Xiaolin; Gong, Jiadi; Chen, Mingxue; Yu, Shasha; Bian, Yingfang; Cao, Zhaoyun

    2014-11-01

    A purification method was established for the analysis of proteomes in rice leaves based on a novel detergent removal spin column (DRSC). The proteins were extracted by phenol protein extraction method followed by sodium dodecyl sulfate (SDS) lysis. The lysate was purified by the detergent removal spin column and the enzymolytic peptides were detected by the nanoflow liquid chromatography-hybrid linear trap quadrupole orbitrap mass spectrometry (nanoLC-LTQ/Orbitrap). In terms of SDS removal efficiencies and protein identification, the method of DRSC was compared with those of filter aided sample preparation (FASP) and acetone precipitation. As a result, there were good efficiencies ( > 95%) of SDS removal for the three methods. With the DRSC purification strategy, 563 proteins were identified from rice leaves, while only 196 and 306 proteins were identified by FASP and acetone precipitation procedures respectively, in spite of certain complementarities among these identified proteins by the three methods. DRSC is suitable for proteins with various relative molecular masses and pI values. However, there were similar losses of proteins with different relative molecular masses and pI values with the other two methods. Using the established method, 588 proteins were identified by once injection analysis. According to the molecular functions, 296 proteins with at least two identified peptides can be classified into eight categories with binding activity, enzyme activity, transporter activity, inhibitor activity, structural constitute, catalytic activity, other and unknown functions. The method provides technical reference for conducting rice proteomes. PMID:25764651

  16. Simultaneous determination of N-acetylaspartylglutamate and N-acetylaspartate in rat brain homogenate using high-performance liquid chromatography with pre-column fluorescence derivatization.

    PubMed

    Arai, Kotaro; Fukushima, Takeshi; Tomiya, Masayuki; Mitsuhashi, Shogo; Sasaki, Tsukasa; Toyo'oka, Toshimasa

    2008-11-15

    Simultaneous determination method of N-acetyl-l-aspartyl-l-glutamate (NAAG), an endogenous agonist at type 3 metabotropic glutamate receptor, and its degradation product, N-acetyl-l-aspartate (NAA) was developed by using reversed-phase high-performance liquid chromatography (HPLC) with pre-column fluorescence derivatization using 4-N,N-dimethylaminosulfonyl-7-N-(2-aminoethyl)amino-2,1,3-benzoxadiazole. The detection limits of NAAG and NAA were approximately 12 and 34 fmol on the column, respectively (signal to noise ratio 3). The proposed HPLC method was applied to determine NAAG and NAA simultaneously in the rat brain homogenate. Both concentrations of NAAG and NAA in the male rat cerebrum (13 weeks old) were 5.7+/-0.30 and 2.1 x 10(2)+/-9.2 nmol/mg protein, respectively (n=6), while those in the hippocampus were 6.8+/-0.48 and 1.9 x 10(2)+/-8.5 nmol/mg protein, respectively (n=5). Hippocampal NAA concentration was significantly increased in the ketamine-treated rats as compared to the control rats (p<0.01). PMID:18835755

  17. The application of phospholipid removal columns and ultra-high performance liquid chromatography-tandem quadrupole mass spectrometry for quantification of multi-class antibiotics in aquaculture samples.

    PubMed

    Reinholds, Ingars; Pugajeva, Iveta; Perkons, Ingus; Bartkevics, Vadims

    2016-09-01

    In this study a robust and sensitive method based on a proposed sample purification procedure, using zirconia-coated Phree™ columns and analysis by ultra-high performance liquid chromatography with triple quadrupole tandem mass spectrometry are presented for the assessment of multi-class antibiotics in farmed fish species. The sample preparation procedure benefited from combined precipitation of proteins and selective removal of phospholipids by Phree™ columns, resulting in a high sensitivity of the method (LOQ 0.3-9mgkg(-1)). The in-house validation results (precision, repeatability, decision limit CCα, detection capability CCβ, etc.) indicate that the elaborated method is fully suitable for the analysis of the main classes of antibiotics in accordance with the European Union (EU) Commission Decision 2002/657/EC. The method was applied to the analysis of antibiotics in trout and sturgeon samples obtained from the local inland aquacultures in Latvia. The results revealed the presence of two antibiotics (enrofloxacin and trimethoprim) in 12 out of the 20 analysed fish samples at concentrations (0.33-12.2μgkg(-1)) below the MRLs, thus causing no acute risks to consumers. PMID:27258648

  18. Temperature-based on-column solute focusing in capillary liquid chromatography reduces peak broadening from precolumn dispersion and volume overload when used alone or with solvent-based focusing

    PubMed Central

    Groskreutz, Stephen R.; Horner, Anthony R.; Weber, Stephen G.

    2015-01-01

    On-column focusing is essential for satisfactory performance using capillary scale columns. On-column focusing results from generating transient conditions at the head of the column that lead to high solute retention. Solvent-based on-column focusing is a well-known approach to achieve this. Temperature-assisted on-column focusing (TASF) can also be effective. TASF improves focusing by cooling a short segment of the column inlet to a temperature that is lower than the column temperature during the injection and then rapidly heating the focusing segment to the match the column temperature. A troublesome feature of an earlier implementation of TASF was the need to leave the capillary column unpacked in that portion of the column inside the fitting connecting it to the injection valve. We have overcome that problem in this work by packing the head of the column with solid silica spheres. In addition, technical improvements to the TASF instrumentation include: selection of a more powerful thermo-electric cooler to create faster temperature changes and electronic control for easy incorporation into conventional capillary instruments. Used in conjunction with solvent-based focusing and with isocratic elution, volumes of paraben samples (esters of p-hydroxybenzoic acid) up to 4.5-times the column liquid volume can be injected without significant bandspreading due to volume overload. Interestingly, the shapes of the peaks from the lowest volume injections that we can make, 30 nL, are improved when using TASF. TASF is very effective at reducing the detrimental effects of precolumn dispersion using isocratic elution. Finally, we show that TASF can be used to focus the neuropeptide galanin in a sample solvent with elution strength stronger than the mobile phase. Here, the stronger solvent is necessitated by the need to prevent peptide adsorption prior to and during analysis. PMID:26091787

  19. Fast separation ultra-performance liquid chromatography for determination of pre-column derivative abamectin and ivermectin residues in vegetable.

    PubMed

    Liu, Hongcheng; Zhang, Ying; Liu, Lianliang; Li, Qiwan; Shao, Jinliang; Zou, Yanhong

    2011-03-01

    A new residue method for quantification of abamectin and ivermectin in vegetable is described in the article. The derivative process is devised that acylating chemical is firstly performed by N-methylimidazole (MI) and trifluoroacetic anhydride (TFAA), then which reacted with hydroxyl function of abamerctin to make fluorescence. The influence of triethylamin (TEA) is examined. Separation is resolute by a short column of 1.7 μm size and operated at high pressure values (10.000 psi). The optimal chromatographic condition and the highest sensitivity are achieved by acetonitrile: water (95: 5), 0.4 mL/min, 0.2 μL injector. The detection limits of abamectin and ivermectin are 1 μg/kg respectively. PMID:20936332

  20. [Determination of six main components in compound theophylline tablet by convolution curve method after prior separation by column partition chromatography

    NASA Technical Reports Server (NTRS)

    Zhang, S. Y.; Wang, G. F.; Wu, Y. T.; Baldwin, K. M. (Principal Investigator)

    1993-01-01

    On a partition chromatographic column in which the support is Kieselguhr and the stationary phase is sulfuric acid solution (2 mol/L), three components of compound theophylline tablet were simultaneously eluted by chloroform and three other components were simultaneously eluted by ammonia-saturated chloroform. The two mixtures were determined by computer-aided convolution curve method separately. The corresponding average recovery and relative standard deviation of the six components were as follows: 101.6, 1.46% for caffeine; 99.7, 0.10% for phenacetin; 100.9, 1.31% for phenobarbitone; 100.2, 0.81% for theophylline; 99.9, 0.81% for theobromine and 100.8, 0.48% for aminopyrine.

  1. Dielectrophoretic Assembly of Semiconducting Carbon Nanotubes Separated and Enriched by Spin Column Chromatography and Its Application to Gas Sensing

    NASA Astrophysics Data System (ADS)

    Nakano, Michihiko; Fujioka, Masahiro; Mai, Kaori; Watanabe, Hideaki; Martin, Yul; Suehiro, Junya

    2012-04-01

    The present authors have previously demonstrated the electrokinetic fabrication of a single-walled carbon nanotube (SWCNT) gas sensor by employing dielectrophoresis. Because this method employs mass-produced SWCNTs, it can realize cheaper and more flexible SWCNT gas sensor fabrication than that based on the on-site synthesis of SWCNTs. In this study, a new protocol was proposed and tested for the separation and enrichment of semiconducting SWCNTs, aiming to improve the SWCNT gas sensor sensitivity. The protocol employed a spin column filled with size-exclusion dextran-based gel beads as well as two surfactants (sodium dodecyl sulfate and sodium deoxycholate), which had different affinities to metallic and semiconducting SWCNTs. The separation and enrichment of the semiconducting SWCNTs were confirmed by measuring their optical and electrical properties. The CNT gas sensor fabricated using enriched semiconducting SWCNTs was highly sensitive to nitrogen dioxide (NO2) gas, - more sensitive by 10 times than that fabricated using the pristine SWCNT mixture.

  2. Determination of the rodenticide difenacoum in biological materials by high-pressure liquid chromatography with confirmation of identity by mass spectrometry.

    PubMed

    Mundy, D E; Machin, A F

    1977-09-21

    A method for determining difenacoum in liver, plasma, urine and feedingstuffs by high-pressure liquid chromatography is described. Samples are cleaned up by molecular exclusion chromatography on porous glass. In some cases this also serves for determination; if not, the separated difenacoum is determined on an adsorption column. Identity is confirmed by chemical ionisation mass spectrometry. Recoveries at levels of 0.025-5 ppm from plasma were 101-113% by exclusion chromatography alone and 93-101% after adsorption chromatography. Recoveries from liver after both chromatographic steps were 62-86%. Reasons for the lower recoveries from liver are suggested. PMID:893620

  3. Column Experiments for Radionuclide Adsorption Studies of the Culebra Dolomite: Retardation Parameter Estimation for Non-Eluted Actinide Species

    SciTech Connect

    Brown, G.O.; Lucero, D.A.; Perkins, W.G.

    1999-01-01

    The U.S. Department of Energy (DOE) has been developing a nuclear waste disposal facility, the Waste Isolation Pilot Plant (WIPP), located approximately 42 km east of Carlsbad, New Mexico. The WIPP is designed to demonstrate the safe disposal of transuranic wastes produced by the defense nuclear-weapons program. Performance assessment analyses (U.S. DOE, 1996) indicate that human intrusion by inadvertent and intermittent drilling for resources provide the only credible mechanisms for significant releases of radionuclides horn the disposal system. These releases may occur by five mechanisms: (1) cuttings, (2) cavings, (3) spallings, (4) direct brine releases, and (5) long-term brine releases. The first four mechanisms could result in immediate release of contaminant to the accessible environment. For the last mechanism, migration pathways through the permeable layers of rock above the Salado are important, and major emphasis is placed on the Culebra Member of the Rustler Formation because this is the most transmissive geologic layer in the disposal system. For reasons of initial quantity, half-life, and specific radioactivity, certain isotopes of Th, U, Am, and Pu would dominate calculated releases from the WIPP. In order to help quanti~ parameters for the calculated releases, radionuclide transport experiments have been carried out using five intact-core columns obtained from the Culebra dolomite member of the Rustler Formation within the Waste Isolation Pilot Plant (WIPP) site in southeastern New Mexico. This report deals primarily with results of mathematical analyses related to the retardation of %J%, 24%, and 24'Am in two of these cores (B-Core - VPX26-11A and C-Core - VPX28-6C). All B-Core transport experiments were done using Culebra-simukmt brine relevant to the core recovery location (the WIPP air-intake shaft - AIS). Most experiments with C-Core were done with AIS brine with some admixture of a brine composition (ERDA-6) that simulated deeper formation

  4. A Laboratory Experiment To Measure Henry's Law Constants of Volatile Organic Compounds with a Bubble Column and a Gas Chromatography Flame Ionization Detector (GC-FID)

    ERIC Educational Resources Information Center

    Lee, Shan-Hu; Mukherjee, Souptik; Brewer, Brittany; Ryan, Raphael; Yu, Huan; Gangoda, Mahinda

    2013-01-01

    An undergraduate laboratory experiment is described to measure Henry's law constants of organic compounds using a bubble column and gas chromatography flame ionization detector (GC-FID). This experiment is designed for upper-division undergraduate laboratory courses and can be implemented in conjunction with physical chemistry, analytical…

  5. Analytical approach to determining human biogenic amines and their metabolites using eVol microextraction in packed syringe coupled to liquid chromatography mass spectrometry method with hydrophilic interaction chromatography column.

    PubMed

    Konieczna, Lucyna; Roszkowska, Anna; Synakiewicz, Anna; Stachowicz-Stencel, Teresa; Adamkiewicz-Drożyńska, Elżbieta; Bączek, Tomasz

    2016-04-01

    Analysis of biogenic amines (BAs) in different human samples provides insight into the mechanisms of various biological processes, including pathological conditions, and thus may be very important in diagnosing and monitoring several neurological disorders and cancerous tumors. In this work, we developed a simple and fast procedure using a digitally controlled microextraction in packed syringe (MEPS) coupled to liquid chromatography mass spectrometry (LC-MS) method for simultaneous determination of biogenic amines, their precursors and metabolites in human plasma and urine samples. The separation of 12 low molecular weight and hydrophilic molecules with a wide range of polarities was achieved with hydrophilic interaction chromatography (HILIC) column without derivatization step in 12 min. MEPS was implemented using the APS sorbent in semi-automated analytical syringe (eVol(®)) and small volume of urine and plasma samples, 5 0µL and 100 μL, respectively. We evaluated important parameters influencing MEPS efficiency, including stationary phase selection, sample pH and volume, number of extraction cycles, and washing and elution volumes. In optimized MEPS conditions, the analytes were eluted by 3 × 50 μL of methanol with 0.1% formic acid. The chromatographic separation of analytes was performed on XBridge Amide™ BEH analytical column (3.0mm × 100 mm, 3.5 µm) using gradient elution with mobile phase consisting of phase A: 10mM ammonium formate buffer in water pH 3.0 and phase B: 10mM ammonium formate buffer in acetonitrile pH 3.0. The LC-HILIC-MS method was validated and, in optimum conditions, presented good linearity in concentration range within 10-2000 ng/mL for all the analytes with a determination coefficient (r(2)) higher than 0.999 for plasma and urine samples. Method recovery ranged within 87.6-104.3% for plasma samples and 84.2-98.6% for urine samples. The developed method utilizing polar APS sorbent along with polar HILIC column was applied for

  6. Luminescent determination of quinolones in milk samples by liquid chromatography/post-column derivatization with terbium oxide nanoparticles.

    PubMed

    Yánez-Jácome, G S; Aguilar-Caballos, M P; Gómez-Hens, A

    2015-07-31

    The usefulness of terbium oxide nanoparticles (Tb4O7NPs) as post-column derivatizing reagent for the liquid chromatographic determination of residues of quinolone antibiotics in milk samples has been studied. Seven quinolones of veterinary use have been chosen as model analytes to develop this method. The derivatization step is based on the formation of luminescent chelates of quinolones with Tb4O7NPs, which are monitored at λex=340nm and λem=545nm. Another relevant feature of the method is that the use of a 10-cm column and a ternary mixture of methanol, acetonitrile and acetic acid as mobile phase in gradient elution mode allow the chromatographic separation of the quinolones in about 13min, whereas previously described chromatographic methods require about 20min. The dynamic ranges of the calibration graphs and limits of detection are, respectively: 65-900ngmL(-1) and 35ngmL(-1) for marbofloxacin, 7.2-900ngmL(-1) and 2.5ngmL(-1) for ciprofloxacin, 6-900ngmL(-1) and 2ngmL(-1) for danofloxacin, 50-900ngmL(-1) and 20ngmL(-1) for enrofloxacin, 35-900ngmL(-1) and 12ngmL(-1) for sarafloxacin, 5-900ngmL(-1) and 2ngmL(-1) for oxolinic acid, and 7-900ngmL(-1) and 2.5ngmL(-1) for flumequine. The precision, established at two concentration levels of each analyte and expressed as the percentage of the relative standard deviation is in the range of 1.9-8.1% using standards, and of 3.4-10.7% in the presence of milk samples. The method has been satisfactorily applied to the analysis of skimmed, semi-skimmed and whole milk samples, with recoveries ranging from 89.0 to 106.5%. PMID:26077970

  7. Loss of bonded phase in reversed-phase liquid chromatography in acidic eluents and practical ways to improve column stability.

    PubMed

    Ma, Lianjia; Carr, Peter W

    2007-06-15

    Silica-based, reversed-phase liquid chromatographic (RPLC) stationary phases are very widely used to separate basic compounds in acidic eluents due to their high efficiency, good mechanical strength, and the versatile selectivity offered by different functional groups and the chemistry on the silica surface. However, the stability in acid of most silica-based stationary phases is poor, especially at elevated temperatures, due to hydrolysis of the siloxane bonds, which hold silanes on the silica substrate. This hydrolysis is commonly believed to be solely the result of catalysis by protons. However, we show that various metal cations (principally Fe3+/Fe2+, Ni2+, and Cr3+) released from acid corrosion of the stainless steel inlet frit greatly accelerate the hydrolysis of the siloxane bond. Furthermore, these metal cations, and not the high acidity per se, are mainly responsible for column instability. We show that removing the stainless steel inlet frit, or use of a titanium frit, greatly reduces or totally eliminates corrosion of the inlet frit and radically improves retention stability. The effects of various acids and types of organic modifier were also studied. These observations suggest a number of practical approaches that can significantly extend the lifetime of any RPLC stationary phase in acidic media at elevated temperature. PMID:17506522

  8. High-performance liquid chromatography separation of phthalate acid esters with a MIL-53(Al)-packed column.

    PubMed

    Shu, Lun; Chen, Sha; Zhao, Wei-Wei; Bai, Yan; Ma, Xing-Chen; Li, Xiao-Xin; Li, Jian-Rong; Somsundaran, P

    2016-08-01

    In this study, a MIL-53(Al)-packed column was successfully prepared and firstly applied to separate phthalate acid esters (butyl benzyl phthalate, di-n-butyl phthalate, diethyl phthalate, bis(2-ethylhexyl) phthalate, and dimethyl phthalate). Their baseline separation could be achieved within 12 min with a mobile phase of methanol/H2 O ratio at 92:8, and the temperature and flow rate was 40°C and 0.6 mL/min, respectively. The stacking effect and electrostatic force were the key factors in the separation. Moreover, there was a substantial linear relation between the peak height, peak area, and the analyte mass, and the relative standard deviations of retention time, peak height, peak area, and half peak width for five replicate separations of the analytes were within the ranges 0.31-0.88%, 0.72-1.52%, 1.33-1.53%, and 0.46-0.95%, respectively. The results of the calculation of the thermodynamics parameters showed that the separation of phthalate acid esters was controlled by both enthalpy change (ΔH) and entropy change (ΔS). PMID:27357380

  9. A liquid chromatography method using a monolithic column for the determination of corticoids in animal feed and animal feeding water.

    PubMed

    Muñiz-Valencia, R; Ceballos-Magaña, S G; Gonzalo-Lumbreras, R; Santos-Montes, A; Izquierdo-Hornillos, R

    2008-08-01

    An HPLC-DAD method for determining corticoids in calf feed and in animal feeding water samples using a monolithic column has been developed and validated. The method optimization included the study of binary mobile phases of water and acetonitrile. The optimum separation was achieved at 40 degrees C, with acetonitrile:H(2)O 29:71 v/v used as mobile phase and a 3 ml/min flow-rate, which resulted in their separation in about 5 min. Two reported sample procedures were applied to feed and for animal feeding water samples prior to HPLC. Method validation was carried out according to the EU criteria established for quantitative screening methods. The results indicate that this method is highly specific, reproducible and accurate. The proposed method was found to be robust and unaffected by small variations in the extraction procedure and in HPLC conditions. The developed method for the determination of corticoids in feed and water samples was also found to be suitable for different kinds of feeds and waters. PMID:18506427

  10. Determination of pesticides in vegetables using large-volume injection column liquid chromatography-electrospray tandem mass spectrometry.

    PubMed

    Hogenboom, A C; Hofman, M P; Kok, S J; Niessen, W M; Brinkman, U A

    2000-09-15

    Direct injection of a large volume (900 microl) of a sample extract onto a liquid chromatographic (LC) column, LC separation and electrospray tandem mass spectrometric detection were used for the quantitative analysis of a wide polarity range of pesticides in carrots and potatoes. Rapid sample preparation involved extraction of a small amount of sample (2 g) with a small volume of organic solvent (3 ml), clean-up over a filter and dilution of the organic extract with the aqueous LC eluent. The extraction efficiency for the selected pesticides was studied using methanol, acetone and acetonitrile as solvents. Evaluation of the performance of the overall method, using extraction with acetonitrile and detection in the selected-reaction-monitoring mode, showed excellent linearity in the range of 2-100 microg/kg with limits of detection of 0.5-2 microg/kg for both types of vegetable. With relative standard deviations of the MS peak area measurements of less than 6.5% (n=8) the repeatability of the method was fully satisfactory. PMID:11045499

  11. Emerging contaminant determination in water samples by liquid chromatography using a monolithic column coupled with a photodiode array detector.

    PubMed

    Salvatierra-Stamp, Vilma Del C; Ceballos-Magaña, Silvia G; Gonzalez, Jorge; Jurado, Jose M; Muñiz-Valencia, Roberto

    2015-06-01

    Concern about the presence of emerging contaminants in the environment has increased because biological activity at low concentrations has been observed. The difficulty of detecting and quantifying these compounds encourages the development of analytical methods with highly sensitive and selective analytical procedures. Pharmaceuticals, pesticides, and industrial chemicals are used and finally discarded to the environment. This paper provides a rapid and sensitive analytical method for the quantification of eight emerging contaminants (carbamazepine, carbofuran, bisphenol A, diuron, 17 α ethinylestradiol, ametryn, carbazole, and triclosan). A two-level full factorial design for optimization of chromatographic separation and sample preparation was performed. The separation using a monolithic column (Onyx C18) achieved baseline resolution for all compounds in 4.6 min. The optimized sample treatment involved a preconcentration step by means of solid-phase extraction using HF Bond Elut-C18 cartridges, achieving an enrichment factor of 2222. Under optimum conditions, good linearity was obtained with a correlation coefficient higher than 0.999. The limits of detection and quantification for carbamazepine, carbofuran, bisphenol A, diuron, 17 α ethinylestradiol, ametryn, and carbazole were in the range of 0.01-208.7 and 0.03-695.7 ng L(-1), respectively, and for triclosan, the limit of detection and quantification was 0.67 and 2.25 μg L(-1), respectively. Precision evaluated as relative standard deviations was lower than 15 %. The proposed method was found robust. Finally, the method was successfully applied to superficial water samples. PMID:25860655

  12. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of semivolatile organic compounds in bottom sediment by solvent extraction, gel permeation chromatographic fractionation, and capillary-column gas chromatography/mass spectrometry

    USGS Publications Warehouse

    Furlong, E.T.; Vaught, D.G.; Merten, L.M.; Foreman, W.T.; Gates, Paul M.

    1996-01-01

    A method for the determination of 79 semivolatile organic compounds (SOCs) and 4 surrogate compounds in soils and bottom sediment is described. The SOCs are extracted from bottom sediment by solvent extraction, followed by partial isolation using high-performance gel permeation chromatography (GPC). The SOCs then are qualitatively identified and quantitative concentrations determined by capillary-column gas chromatography/mass spectrometry (GC/MS). This method also is designed for an optional simultaneous isolation of polychlorinated biphenyls (PCBs) and organochlorine (OC) insecticides, including toxaphene. When OCs and PCBs are determined, an additional alumina- over-silica column chromatography step follows GPC cleanup, and quantitation is by dual capillary- column gas chromatography with electron-capture detection (GC/ECD). Bottom-sediment samples are centrifuged to remove excess water and extracted overnight with dichloromethane. The extract is concentrated, centrifuged, and then filtered through a 0.2-micrometer polytetrafluoro-ethylene syringe filter. Two aliquots of the sample extract then are quantitatively injected onto two polystyrene- divinylbenzene GPC columns connected in series. The SOCs are eluted with dichloromethane, a fraction containing the SOCs is collected, and some coextracted interferences, including elemental sulfur, are separated and discarded. The SOC-containing GPC fraction then is analyzed by GC/MS. When desired, a second aliquot from GPC is further processed for OCs and PCBs by combined alumina-over-silica column chromatography. The two fractions produced in this cleanup then are analyzed by GC/ECD. This report fully describes and is limited to the determination of SOCs by GC/MS.

  13. Effect of the endcapping of reversed-phase high-performance liquid chromatography adsorbents on the adsorption isotherm

    SciTech Connect

    Gritti, Fabrice; Guiochon, Georges A

    2005-09-01

    The retention mechanisms of n-propylbenzoate, 4-t ert-butylphenol, and caffeine on the endcapped Symmetry-C{sub 18} and the non-endcapped Resolve-C{sub 18} are compared. The adsorption isotherms were measured by frontal analysis (FA), using as the mobile phase mixtures of methanol or acetonitrile and water of various compositions. The isotherm data were modeled and the adsorption energy distributions calculated. The surface heterogeneity increases faster with decreasing methanol concentration on the non-endcapped than on the endcapped adsorbent. For instance, for methanol concentrations exceeding 30% (v/v), the adsorption of caffeine is accounted for by assuming three and two different types of adsorption sites on Resolve-C{sub 18} and Symmetry-C{sub 18}, respectively. This is explained by the effect of the mobile phase composition on the structure of the C{sub 18}-bonded layer. The bare surface of bonded silica appears more accessible to solute molecules at high water contents in the mobile phase. On the other hand, replacing methanol by a stronger organic modifier like acetonitrile dampens the differences between non-endcapped and endcapped stationary phase and decreases the degree of surface heterogeneity of the adsorbent. For instance, at acetonitrile concentrations exceeding 20%, the surface appears nearly homogeneous for the adsorption of caffeine.

  14. [Determination of seven biothiols in rice by high performance liquid chromatography-fluorescence detection with pre-column derivatization].

    PubMed

    Zhou, Rong; Cao, Zhaoyun; Mou, Renxiang; Li, Zhengxiang; Chen, Mingxue

    2015-01-01

    A high performance liquid chromatographic method with fluorescence detection and precolumn derivatization (HPLC-FLD) has been developed for the determination of seven biothiols including Cys, GSH, and phytochelatins (PCs: PC2, PC3, PC4, PC5 and PC6) in rice. The samples were ultrasonically extracted with 0.1% trifluoroacetic acid (TFA) containing 6. 3 mmol/L diethylenetriaminepentaacetic acid (DTPA), and then the seven biothiols were derivatized with monobromobimane (mBrB) as derivatization agent in 4-(2-hydroxyethyl)-1-piperazine propanesulfonic acid (HEPPS) buffer solution (pH 8.0). The separation was performed on an Agilent Eclipse Plus C18 column (50 mm x 4.6 mm, 5 microm) with gradient elution of 0.1% TFA solution (the pH value was adjusted to 2.5 with hydrochloric acid) and acetonitrile as mobile phases at a flow rate of 0.8 mL/min. The detection was performed at 380 nm for excitation and 470 nm for emission. The calibration curves of the seven biothiols showed good linearity in the concentration range of 0.7-100.0 mg/L with the correlation coefficients (r2) > or = 0.9991. The limits of detection were 0.03-0.20 mg/L. The recoveries of standard addition were in the range of 89.26%-99.42% with the relative standard deviations (RSDs, n = 6) of 2.05%-5.87%. The method is sensitive, accurate, reproducible and suitable for the simultaneous determination of Cys, GSH, PC2, PC3, PC4, PC5 and PC6 in rice. PMID:25958665

  15. Investigation of the adsorption mechanism of a peptide in reversed phase liquid chromatography, from pH controlled and uncontrolled solutions

    SciTech Connect

    Gritti, Fabrice; Guiochon, Georges A

    2009-01-01

    The single-component equilibrium adsorption of the tripeptide Leucyl-Leucyl-Leucine (LLL) on a high-efficiency Jupiter Proteo column (C{sub 12}) was investigated experimentally and modeled theoretically. The experimental equilibrium isotherms of LLL for adsorption on a C{sub 12} packing material from an aqueous solution of methanol (48%) and trifluoroacetic acid (0.1%) were measured by frontal analysis (FA). The FA measurements were done with two solutions, one in which the pH was controlled, the other in which it was not. Two solutions of LLL in the mobile phase were prepared (4.3 and 5.4 g/L) and their pH measured (2.94 and 2.88), respectively. The first solution was titrated with TFA to match the pH of the mobile phase (2.03), so its pH was controlled. The pH of the other solution was left uncontrolled. In both cases the isotherms could be modeled by a bi-Langmuir equation, a choice consistent with the bimodal affinity energy distribution (AED) obtained for LLL. The isotherm parameters derived from the inverse method (IM) of isotherm determination under controlled pH conditions (by fitting calculated profiles to experimental breakthrough profiles) are in a good agreement with those derived from the FA data. Under uncontrolled pH conditions, the application of IM suggests the coexistence of two different adsorption mechanisms. According to the isotherm parameters found by these three methods (FA, AED and IM), the C{sub 12}-bonded silica can adsorb around 500 and 70 g/L of LLL under controlled and uncontrolled pH conditions, respectively. The adsorption of LLL on the C{sub 12} material strongly depends on the pH of the mobile phase and on the quantity of TFA added, which plays the role of an ion-pairing agent.

  16. Identification of the AntiListerial Constituents in Partially Purified Column Chromatography Fractions of Garcinia kola Seeds and Their Interactions with Standard Antibiotics

    PubMed Central

    Penduka, D.; Buwa, L.; Mayekiso, B.; Basson, A. K.; Okoh, A. I.

    2014-01-01

    Partially purified fractions of the n-hexane extract of Garcinia kola seeds were obtained through column chromatography and their constituents were identified through the use of gas chromatography coupled to mass spectrometry (GC-MS). Three fractions were obtained by elution with benzene as the mobile phase and silica gel 60 as the stationery phase and these were named Benz1, Benz2, and Benz3 in the order of their elution. The antiListerial activities of these fractions were assessed through MIC determination and only Benz2 and Benz3 were found to be active with MIC's ranging from 0.625 to 2.5 mg/mL. The results of the GC-MS analysis showed Benz2 to have 9 compounds whilst Benz3 had 7 compounds, with the major compounds in both fractions being 9,19-Cyclolanost-24-en-3-ol, (3.β.) and 9,19-Cyclolanostan-3-ol,24-methylene-, (3.β.). The Benz2 fraction was found to have mainly indifferent interactions with ampicillin and penicillin G whilst mainly additive interactions were observed with ciprofloxacin. The Benz3 fraction's interactions were found to be 50% synergistic with penicillin G and 25% synergistic with ciprofloxacin and ampicillin. A commercially available 9,19-Cyclolanost-24-en-3-ol, (3.β.) was found not to exhibit any antiListerial activities at maximum test concentrations of 5 mg/mL, suggesting that the compound could be acting in synergy with the other compounds in the eluted fractions of Garcinia kola seeds. PMID:24527056

  17. Identification of the AntiListerial Constituents in Partially Purified Column Chromatography Fractions of Garcinia kola Seeds and Their Interactions with Standard Antibiotics.

    PubMed

    Penduka, D; Buwa, L; Mayekiso, B; Basson, A K; Okoh, A I

    2014-01-01

    Partially purified fractions of the n-hexane extract of Garcinia kola seeds were obtained through column chromatography and their constituents were identified through the use of gas chromatography coupled to mass spectrometry (GC-MS). Three fractions were obtained by elution with benzene as the mobile phase and silica gel 60 as the stationery phase and these were named Benz1, Benz2, and Benz3 in the order of their elution. The antiListerial activities of these fractions were assessed through MIC determination and only Benz2 and Benz3 were found to be active with MIC's ranging from 0.625 to 2.5 mg/mL. The results of the GC-MS analysis showed Benz2 to have 9 compounds whilst Benz3 had 7 compounds, with the major compounds in both fractions being 9,19-Cyclolanost-24-en-3-ol, (3. β .) and 9,19-Cyclolanostan-3-ol,24-methylene-, (3. β .). The Benz2 fraction was found to have mainly indifferent interactions with ampicillin and penicillin G whilst mainly additive interactions were observed with ciprofloxacin. The Benz3 fraction's interactions were found to be 50% synergistic with penicillin G and 25% synergistic with ciprofloxacin and ampicillin. A commercially available 9,19-Cyclolanost-24-en-3-ol, (3. β .) was found not to exhibit any antiListerial activities at maximum test concentrations of 5 mg/mL, suggesting that the compound could be acting in synergy with the other compounds in the eluted fractions of Garcinia kola seeds. PMID:24527056

  18. Development of an Enzyme-Linked Immunosorbent Assay and Immunoaffinity Column Chromatography for Saikosaponin d Using an Anti-Saikosaponin d Monoclonal Antibody.

    PubMed

    Sai, Jiayang; Zhao, Yan; Shan, Wenchao; Qu, Baoping; Zhang, Yue; Cheng, Jinjun; Qu, Huihua; Wang, Qingguo

    2016-03-01

    This work developed a novel immunochemical approach for the quality control of saikosaponin d using an enzyme-linked immunosorbent assay. Splenocytes from mice immunized with the saikosaponin d-bovine serum albumin conjugate were fused with the hypoxanthine-aminopterin-thymidine-sensitive mouse myeloma SP2/0 cell line, and a hybridoma secreting monoclonal antibody against saikosaponin d was successfully obtained. The prepared anti-saikosaponin d monoclonal antibody 1E7F3 has a novel characteristic, showing weak reactivity with compounds that are structurally related to saikosaponin d. Using monoclonal antibody 1E7F3, a specific and reliable enzyme-linked immunosorbent assay was developed to detect saikosaponin d. The system shows a full measurement range from 156.25 to 5000.00 ng × mL(-1). Both intra-assay and inter-assay repeatability and precision were achieved, with relative standard deviations lower than 10.00 %. The recovery rates ranged from 92.36 % to 101.00 %, meeting the requirements for biological samples. There was a good correlation between the enzyme-linked immunosorbent assay and high-performance liquid chromatography analyses of saikosaponin d, and the saikosaponin d levels in formulated Chinese medicines were successfully determined. Furthermore, immunoaffinity column chromatography was established using this anti-saikosaponin d monoclonal antibody, and the elution profile of saikosaponin d was detected by a Bio-Rad QuadTec UV/Vis detector at 203 nm. The results demonstrate that we generated a reliable and more efficient assay system for measuring saikosaponin d and provide a potential approach for purifying and separating saikosaponin d. PMID:26824622

  19. A high-performance liquid chromatography assay with a triazole-bonded column for evaluation of d-amino acid oxidase activity.

    PubMed

    Iwasaki, Megumi; Kashiwaguma, Yoshiyuki; Nagashima, Chihiro; Izumi, Mao; Uekusa, Ayano; Iwasa, Sumiko; Onozato, Mayu; Ichiba, Hideaki; Fukushima, Takeshi

    2016-03-01

    Elution profiles of kynurenic acid (KYNA) and 7-chlorokynurenic acid (Cl-KYNA) were examined by high-performance liquid chromatography (HPLC) using a triazole-bonded stationary phase column (Cosmosil® HILIC) under isocratic elution of a mobile phase consisting of CH3 CN-aqueous 10 mm ammonium formate between pH 3.0 and 6.0. The capacity factors of KYNA and Cl-KYNA varied with both the CH3 CN content and the pH of the mobile phase. The elution order of KYNA and Cl-KYNA was reversed between the CH3 CN- and H2 O-rich mobile phases, suggesting that hydrophilic interactions and anion-exchange interactions caused retention of KYNA and Cl-KYNA in the CH3 CN- and H2 O-rich mobile phases, respectively. The present HPLC method using a triazole-bonded column and fluorescence detection (excitation 250 nm, emission 398 nm) was applied to monitor in vitro production of KYNA from d-kynurenine (d-KYN) by d-amino acid oxidase (DAO) using Cl-KYNA as an internal standard. A single KYNA peak was clearly observed after enzymatic reaction of d-KYN with DAO. Production of KYNA from d-KYN was suppressed by the addition of commercial DAO inhibitors. The present HPLC method can be used to evaluate DAO activity and DAO inhibitory effects in candidate drugs for the treatment of schizophrenia. PMID:26174062

  20. Determination of phenolic acids and flavonoids in Taraxacum formosanum Kitam by liquid chromatography-tandem mass spectrometry coupled with a post-column derivatization technique.

    PubMed

    Chen, Hung-Ju; Inbaraj, Baskaran Stephen; Chen, Bing-Huei

    2012-01-01

    A liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed for the determination of phenolic acids and flavonoids in a medicinal Chinese herb Taraxacum formosanum Kitam. Initially, both phenolic acids and flavonoids were extracted with 50% ethanol in a water-bath at 60 °C for 3 h and eventually separated into acidic fraction and neutral fraction by using a C(18) cartridge. A total of 29 compounds were separated within 68 min by employing a Gemini C(18) column and a gradient solvent system of 0.1% formic acid and acetonitrile at a flow rate of 1.0 mL/min. Based on the retention behavior as well as absorption and mass spectra, 19 phenolic acids and 10 flavonoids were identified and quantified in T. formosanum, with the former ranging from 14.1 μg/g to 10,870.4 μg/g, and the latter from 9.9 μg/g to 325.8 μg/g. For further identification of flavonoids, a post-column derivatization method involving shift reagents such as sodium acetate or aluminum chloride was used and the absorption spectral characteristics without or with shift reagents were compared. An internal standard syringic acid was used for quantitation of phenolic acids, whereas (±) naringenin was found suitable for quantitation of flavonoids. The developed LC-MS/MS method showed high reproducibility, as evident from the relative standard deviation (RSD) values for intra-day and inter-day variability being 1.0-6.8% and 2.0-7.7% for phenolic acids and 3.7-7.4% and 1.5-8.1% for flavonoids, respectively, and thus may be applied for simultaneous determination of phenolic acids and flavonoids in Chinese herb and nutraceuticals. PMID:22312251

  1. Determination of Myo-Inositol in Infant, Pediatric, and Adult Formulas by Liquid Chromatography-Pulsed Amperometric Detection with Column Switching: Collaborative Study, Final Action 2011.18.

    PubMed

    Butler-Thompson, Linda D; Jacobs, Wesley A; Schimpf, Karen J

    2015-01-01

    AOAC First Action Method 2011.18, Myo-Inositol (Free and Bound as Phosphatidylinositol) in Infant and Pediatric Formulas and Adult Nutritionals, was collaboratively studied. With this method free myo-inositol and phosphatidylinositol bound myo-inositol are extracted using two different sample preparation procedures, separated by ion chromatography using a combination of Dionex Carbo Pac PA1 and MA1 columns with column switching, and detected with pulsed amperometry using a gold electrode. Free myo-inositol is extracted from samples with dilute hydrochloric acid and water. Phosphatidylinositol is extracted from samples with chloroform and separated from other fats with silica SPE cartridges. Myo-inositol is then released from the glycerol backbone with concentrated acetic and hydrochloric acids at 120°C. During this collaborative study, nine laboratories from five different countries analyzed blind duplicates of nine infant and pediatric nutritional formulas for both free and phosphatidylinositol bound myo-inositol, and one additional laboratory only completed the free myo-inositol analyses. The method demonstrated acceptable repeatability and reproducibility and met the AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN) Standard Method Performance Requirements (SMPRs®) for free myo-inositol plus phosphatidylinositol bound myo-inositol for all the matrixes analyzed. SMPRs for repeatability were ≤5% RSD at myo-inositol concentrations of 2-68 mg/100 g ready-to-feed (RTF) liquid. SMPRs for reproducibility were ≤8% RSD in products with myo-inositol concentrations ranging from 2 to 68 mg/100 g RTF liquid. During this collaborative study, repeatability RSDs ranged from 0.51 to 3.22%, and RSDs ranged from 2.66 to 7.55% for free myo-inositol plus phosphatidylinositol bound myo-inositol. PMID:26651580

  2. Determination of Phenolic Acids and Flavonoids in Taraxacum formosanum Kitam by Liquid Chromatography-Tandem Mass Spectrometry Coupled with a Post-Column Derivatization Technique

    PubMed Central

    Chen, Hung-Ju; Inbaraj, Baskaran Stephen; Chen, Bing-Huei

    2012-01-01

    A liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed for the determination of phenolic acids and flavonoids in a medicinal Chinese herb Taraxacum formosanum Kitam. Initially, both phenolic acids and flavonoids were extracted with 50% ethanol in a water-bath at 60 °C for 3 h and eventually separated into acidic fraction and neutral fraction by using a C18 cartridge. A total of 29 compounds were separated within 68 min by employing a Gemini C18 column and a gradient solvent system of 0.1% formic acid and acetonitrile at a flow rate of 1.0 mL/min. Based on the retention behavior as well as absorption and mass spectra, 19 phenolic acids and 10 flavonoids were identified and quantified in T. formosanum, with the former ranging from 14.1 μg/g to 10,870.4 μg/g, and the latter from 9.9 μg/g to 325.8 μg/g. For further identification of flavonoids, a post-column derivatization method involving shift reagents such as sodium acetate or aluminum chloride was used and the absorption spectral characteristics without or with shift reagents were compared. An internal standard syringic acid was used for quantitation of phenolic acids, whereas (±) naringenin was found suitable for quantitation of flavonoids. The developed LC-MS/MS method showed high reproducibility, as evident from the relative standard deviation (RSD) values for intra-day and inter-day variability being 1.0–6.8% and 2.0–7.7% for phenolic acids and 3.7–7.4% and 1.5–8.1% for flavonoids, respectively, and thus may be applied for simultaneous determination of phenolic acids and flavonoids in Chinese herb and nutraceuticals. PMID:22312251

  3. A new method for rapid determination of indole-3-carbinol and its condensation products in nutraceuticals using core-shell column chromatography method.

    PubMed

    Fibigr, Jakub; Šatínský, Dalibor; Havlíková, Lucie; Solich, Petr

    2016-02-20

    Indole-3-carbinol is a natural glucosinolate known for prevention of human breast, prostate and other types of cancer and it started to be used in commercial preparations, as food supplements. However no analytical method has been proposed for quality control of nutraceuticals with this substance yet. In this paper a new high-performance liquid chromatography (HPLC) method using core-shell column for separation of indole-3-carbinol and its condensation/degradation products was developed and used for the quantitative determination of indole-3-carbinol in nutraceuticals. Separation of indole-3-carbinol, its condensation/degradation products and internal standard ethylparaben was performed on the core-shell column Kinetex 5μ XB-C18 100A (100×4.6mm), particle size 5.0μm, with mobile phase acetonitrile/water according to the gradient program at a flow rate of 1.25mLmin(-1) and at temperature 50°C. The detection wavelength was set at 270nm. Under the optimal chromatographic conditions good linearity of determination was achieved. Available commercial samples of nutraceuticals were extracted with 100% methanol using ultrasound bath. A 5-μL sample volume of the supernatant was directly injected into the HPLC system. The developed method provided rapid and accurate tool for quality control of nutraceuticals based on cruciferous vegetable extracts with indole-3-carbinol content. The presented study showed that the declared content of indole-3-carbinol significantly varied in the different nutraceuticals available on the market. Two analyzed preparations showed the presence of condensation/degradation products of indole-3-carbinol which were not officially declared by the manufacturer. Moreover, further two analyzed nutraceutical preparations showed absolutely no content of declared amount of indole-3-carbinol. PMID:26795880

  4. Separation of intact proteins on γ-ray-induced polymethacrylate monolithic columns: A highly permeable stationary phase with high peak capacity for capillary high-performance liquid chromatography with high-resolution mass spectrometry.

    PubMed

    Simone, Patrizia; Pierri, Giuseppe; Foglia, Patrizia; Gasparrini, Francesca; Mazzoccanti, Giulia; Capriotti, Anna Laura; Ursini, Ornella; Ciogli, Alessia; Laganà, Aldo

    2016-01-01

    Polymethacrylate-based monolithic capillary columns, prepared by γ-radiation-induced polymerization, were used to optimize the experimental conditions (nature of the organic modifiers, the content of trifluoroacetic acid and the column temperature) in the separation of nine standard proteins with different hydrophobicities and a wide range of molecular weights. Because of the excellent permeability of the monolithic columns, an ion-pair reversed-phase capillary liquid chromatography with high-resolution mass spectrometry method has been developed by coupling the column directly to the mass spectrometer without a flow-split and using a standard electrospray interface. Additionally, the high working flow and concomitant high efficiency of these columns allowed us to employ a longer column (up to 50 cm) and achieve a peak capacity value superior to 1000. This work is motivated by the need to develop new materials for high-resolution chromatographic separation that combine chemical stability at elevated temperatures (up to 75°C) and a broad pH range, with a high peak capacity value. The advantage of the γ-ray-induced monolithic column lies in the batch-to-batch reproducibility and long-term high-temperature stability. Their proven high loading capacity, recovery, good selectivity and high permeability, moreover, compared well with that of a commercially available poly(styrene-divinylbenzene) monolithic column, which confirms that such monolithic supports might facilitate analysis in proteomics. PMID:26530449

  5. Preparative reversed-phase high-performance liquid chromatography collection efficiency for an antimicrobial peptide on columns of varying diameters (1 mm to 9.4 mm I.D.)

    PubMed Central

    Chen, Yuxin; Mant, Colin T.; Hodges, Robert S.

    2009-01-01

    The present study examines the effect of reversed-phase high-performance liquid chromatography (RP-HPLC) column diameter (1 mm to 9.4 mm I.D.) on the one-step slow gradient preparative purification of a 26-residue synthetic antimicrobial peptide. When taken together, the semi-preparative column (9.4 mm I.D.) provided the highest yields of purified product (an average of 90.7% recovery from hydrophilic and hydrophobic impurities) over a wide range of sample load (0.75–200 mg). Columns with smaller diameters, such as narrowbore columns (150 × 2.1 mm I.D.) and microbore columns (150 × 1.0 mm I.D.), can be employed to purify peptides with reasonable recovery of purified product but the range of the crude peptide that can be applied to the column is limited. In addition, the smaller diameter columns require more extensive fraction analysis to locate the fractions of pure product than the larger diameter column with the same load. Our results show the excellent potential of the one-step slow gradient preparative protocol as a universal method for purification of synthetic peptides. PMID:17156789

  6. The use of biopartitioning micellar chromatography and immobilized artificial membrane column for in silico and in vitro determination of blood-brain barrier penetration of phenols.

    PubMed

    Stępnik, Katarzyna E; Malinowska, Irena

    2013-04-19

    Biopartitioning Micellar Chromatography (BMC) is a mode of micellar liquid chromatography that uses C18 stationary phases and micellar mobile phases of Brij35 under adequate experimental conditions and can be useful to mimic human drug absorption, blood-brain barrier distribution or partitioning processes in biological systems. BMC system can be useful in constructing good predictive models because the characteristics of the BMC system are similar to biological barriers and extracellular fluids. Immobilized Artificial Membrane (IAM) chromatography uses stationary phase which consists of a monolayer of phosphatidylcholine covalently immobilized on an inert silica support. IAM columns are thought to mimic very closely a membrane bilayer and are used in a HPLC system with a physiological buffer as eluent. In this paper the usefulness of BMC and IAM system for in silico and in vitro determination of blood-brain barrier (BBB) penetration of phenols has been demonstrated. The most important pharmacokinetic parameters of brain have been obtained for the determination of BBB penetration, i.e. BBB permeability - surface area product (PS), usually given as a logPS, brain/plasma equilibration rate (log(PS×fu,brain)) and fraction unbound in plasma (Fu). Moreover, the relationships between retention of eighteen phenols and different parameters of molecular size, lipophilicity and BBB penetration were studied. Extrapolated to pure water values of the logarithms of retention factors (logkw) have been compared with the corresponding octanol-water partition coefficient (logPo-w) values of the solutes. In addition, different physicochemical parameters from Foley's equation for BMC system have been collated with the chromatographic data. The Linear Solvation Energy Relationship (LSER) using Abraham model for the describing of phenols penetration across BBB has been used. Four equations were developed as a multiple linear regression using retention data from IAM and BMC system (QRAR

  7. Preparative Isolation of Two Prenylated Biflavonoids from the Roots and Rhizomes of Sinopodophyllum emodi by Sephadex LH-20 Column and High-Speed Counter-Current Chromatography.

    PubMed

    Sun, Yan-Jun; Pei, Li-Xin; Wang, Kai-Bo; Sun, Yin-Shi; Wang, Jun-Min; Zhang, Yan-Li; Gao, Mei-Ling; Ji, Bao-Yu

    2015-01-01

    Two prenylated biflavonoids, podoverines B-C, were isolated from the dried roots and rhizomes of Sinopodophyllum emodi using a Sephadex LH-20 column (SLHC) and high-speed counter-current chromatography (HSCCC). The 95% ethanol extract was partitioned with ethyl acetate in water. Target compounds from the ethyl acetate fraction were further enriched and purified by the combined application of SLHC and HSCCC. n-Hexane-ethyl acetate-methanol-water (3.5:5:3.5:5, v/v) was chosen as the two phase solvent system. The flow rate of mobile phase was optimized at 2.0 mL·min(-1). Finally, under optimized conditions, 13.8 mg of podoverine B and 16.2 mg of podoverine C were obtained from 200 mg of the enriched sample. The purities of podoverines B and C were 98.62% and 99.05%, respectively, as determined by HPLC. For the first time, podoverins B and C were found in the genus Sinopodophyllum. Their structures were determined by spectroscopic methods (HR-ESI-MS, ¹H-NMR, (13)C-NMR, HSQC, HMBC). Their absolute configurations were elucidated by comparison of their experimental and calculated ECD spectra. The cytotoxic activities were evaluated against MCF-7 and HepG2 cell lines. The separation procedures proved to be practical and economical, especially for trace prenylated biflavonoids from traditional Chinese medicine. PMID:26703555

  8. Simultaneous determination of 13 quinolones in eggs using column high-performance liquid chromatography/electrospray ionization-tandem mass spectrometry and depletion of pefloxacin methanesulfonate in eggs.

    PubMed

    Shen, Jianzhong; Li, Haiyan; Jiang, Haiyang; Zhou, Degang; Xu, Fei; Li, Jiancheng; Ding, Shuangyang

    2008-01-01

    An efficient method was developed for simultaneous determination of 13 quinolones--namely, enoaxacin (ENO), marbofloxacin (MAR), ciprofloxacin (CIP), norfloxacin (NOR), ofloxacin (OFL), pefloxacin methanesulfonate (PEF), danofloxacin (DAN), enrofloxacin (ENR), lomefloxacin (LOM), difloxacin (DIF), sarafloxacin (SAR), oxolinic acid (OXO), and flumequine (FLU)--in eggs by column liquid chromatography/electrospray ionization-tandem mass spectrometry. Samples were extracted with a phosphoric acid-phosphate buffer followed by purification with a solid-phase extraction cartridge. Recoveries for the 13 quinolones were 67-93% with intraday and interday coefficients of variation ranging from 4 to 9% and 2 to 18%, respectively. The limit of determination was 0.05 microg/kg for OXO and FLU; 0.1 microg/kg for MAR, OFL, CIP, LOM, DAN, SAR, DIF, NOR, and ENR; and 0.2 microg/kg for ENO and PEF. The method was also applied to study the depletion of PEF in eggs. The concentration of PEF increased and reached a maximum value on the third day, and then decreased rapidly until it could not be detected on day 32; its metabolite NOR was detectable on the second day, and then reached a maximum on the sixth day, after which it could not be detected until day 15. PMID:19202815

  9. Rapid determination of 12 antibiotics and caffeine in sewage and bioreactor effluent by online column-switching liquid chromatography/tandem mass spectrometry.

    PubMed

    Lima Gomes, Paulo C F; Tomita, Inês N; Santos-Neto, Álvaro J; Zaiat, Marcelo

    2015-11-01

    This study presents a column-switching solid-phase extraction online-coupled to a liquid chromatography/tandem mass spectrometry (SPE-LC-MS/MS) method for simultaneous analysis of 12 antibiotics (7 sulfonamides and 5 fluoroquinolones) and caffeine detected in the sewage and effluent of a pilot anaerobic reactor used in sewage treatment. After acidification and filtration, the samples were directly injected into a simple and conventional LC system. Backflush and foreflush modes were compared based on the theoretical plates and peak asymmetry observed. The method was tested in terms of detection (MDL) and quantification limit (MQL), linearity, relative recovery, and precision intra- and inter-day in lab-made sewage samples. The method presented suitable figures of merit in terms of detection, varying from 8.00 × 10(-5) to 6.00 × 10(-2) ng (0.800 up to 600 ng L(-1); caffeine) with direct injection volume of only 100 μL and 13 min of total analysis time (sample preparation and chromatographic run). When the method was applied in the analysis of sewage and effluent of the anaerobic reactor (n = 15), six antibiotics and caffeine were detected in concentrations ranging from 0.018 to 1097 μg L(-1). To guarantee a reliable quantification, standard addition was used to overcome the matrix effect. PMID:26446896

  10. Determination of Wastewater Compounds in Whole Water by Continuous Liquid-Liquid Extraction and Capillary-Column Gas Chromatography/Mass Spectrometry

    USGS Publications Warehouse

    Zaugg, Steven D.; Smith, Steven G.; Schroeder, Michael P.

    2006-01-01

    A method for the determination of 69 compounds typically found in domestic and industrial wastewater is described. The method was developed in response to increasing concern over the impact of endocrine-disrupting chemicals on aquatic organisms in wastewater. This method also is useful for evaluating the effects of combined sanitary and storm-sewer overflow on the water quality of urban streams. The method focuses on the determination of compounds that are indicators of wastewater or have endocrine-disrupting potential. These compounds include the alkylphenol ethoxylate nonionic surfactants, food additives, fragrances, antioxidants, flame retardants, plasticizers, industrial solvents, disinfectants, fecal sterols, polycyclic aromatic hydrocarbons, and high-use domestic pesticides. Wastewater compounds in whole-water samples were extracted using continuous liquid-liquid extractors and methylene chloride solvent, and then determined by capillary-column gas chromatography/mass spectrometry. Recoveries in reagent-water samples fortified at 0.5 microgram per liter averaged 72 percent ? 8 percent relative standard deviation. The concentration of 21 compounds is always reported as estimated because method recovery was less than 60 percent, variability was greater than 25 percent relative standard deviation, or standard reference compounds were prepared from technical mixtures. Initial method detection limits averaged 0.18 microgram per liter. Samples were preserved by adding 60 grams of sodium chloride and stored at 4 degrees Celsius. The laboratory established a sample holding-time limit prior to sample extraction of 14 days from the date of collection.

  11. Hydrophilic interaction liquid chromatography-tandem mass spectrometry methylphosponic and alkyl methylphosphonic acids determination in environmental samples after pre-column derivatization with p-bromophenacyl bromide.

    PubMed

    Baygildiev, T M; Rodin, I A; Stavrianidi, A N; Braun, A V; Lebedev, A T; Rybalchenko, I V; Shpigun, O A

    2016-04-15

    Once exposed to the environment organophosphate nerve agents readily degrade by rapid hydrolysis to the corresponding alkyl methylphosphonic acids which do not exist in nature. These alkyl methylphosphonic acids are finally slowly hydrolyzed to methylphosphonic acid. Methylphosphonic acid is the most stable hydrolysis product of organophosphate nerve agents, persisting in environment for a long time. A highly sensitive method of methylphosphonic acid and alkyl methylphosphonic acids detection in dust and ground mixed samples has been developed and validated. The fact that alkyl methylphosphonic acids unlike methylphosphonic acid did not react with p-bromophenacyl bromide under chosen conditions was discovered. This allowed simultaneous chromatographic separation and mass spectrometric detection of derivatized methylphosphonic acid and underivatized alkyl methylphosphonic acids using HILIC-MS/MS method. Very simple sample pretreatment with high recoveries for each analyte was developed. Methylphosphonic acid pre-column derivate and alkyl methylphosphonic acids were detected using tandem mass spectrometry with electrospray ionization after hydrophilic interaction liquid chromatography separation. The developed approach allows achieving ultra-low detection limits: 200 pg mL(-1) for methylphosphonic acid, 70 pg mL(-1) for ethyl methylphosphonic acid, 8 pg mL(-1) for i-propyl methylphosphonic acid, 8 pg mL(-1) for i-butyl methylphosphonic acid, 5 pg mL(-1) for pinacolyl methylphosphonic acid in the extracts of dust and ground mixed samples. This approach was successfully applied to the dust and ground mixed samples from decommissioned plant for the production of chemical weapons. PMID:26965649

  12. Determination of seven neonicotinoid insecticides in beeswax by liquid chromatography coupled to electrospray-mass spectrometry using a fused-core column.

    PubMed

    Yáñez, Karen P; Bernal, José L; Nozal, María J; Martín, María T; Bernal, José

    2013-04-12

    A new method has been developed to measure seven neonicotinoid insecticides (acetamiprid, clothianidin, dinotefuran, imidacloprid, nitenpyram, thiacloprid and thiamethoxam) in beeswax using liquid chromatography (LC) coupled to electrospray ionization mass spectrometry (ESI-MS) detection. Beeswax was melted and diluted in an n-hexane/isopropanol (8:2, v/v) mixture. After this, liquid extraction with water was performed followed by a clean-up on diatomaceous material based cartridges. The compounds were eluted with acetone, and the resulting solution was evaporated until dry and reconstituted with a mixture of water and acetonitrile 50:50 (v/v). The separation of all compounds was achieved in less than 15 min using a C18 reverse-phase fused-core column (Kinetex C18, 150 mm × 4.6 mm i.d.) and a mobile phase composed of a mixture of 0.1% formic acid in water and acetonitrile in gradient elution mode at 0.5 mL/min. This method was fully validated in terms of selectivity, linearity, precision and recovery. Low limits of detection and quantification could be achieved for all analytes ranging from 0.4 to 2.3 μg/kg, and from 1.5 to 7.0 μg/kg, respectively. Finally, the proposed method was applied to an analysis of neonicotinoid residues in beeswax samples from apiaries located close to fruit orchards. PMID:23473513

  13. Development and characterization of the α3β4α5 nicotinic receptor cellular membrane affinity chromatography column and its application for on line screening of plant extracts.

    PubMed

    Ciesla, L; Okine, M; Rosenberg, A; Dossou, K S S; Toll, L; Wainer, I W; Moaddel, R

    2016-01-29

    The α3β4α5 nAChR has been recently shown to be a useful target for smoking cessation pharmacotherapies. Herein, we report on the development and characterization of the α3β4α5 nicotinic receptor column by frontal displacement chromatography. The binding affinity of the nicotine and minor alkaloids found in tobacco smoke condensates were determined for both the α3β4 and α3β4α5 nicotinic receptors. It was demonstrated that while no subtype selectivity was observed for nicotine and nornicotine, anabasine was selective for the α3β4α5 nicotinic receptor. The non-competitive inhibitor binding site was also studied and it was demonstrated while mecamylamine was not selective between subtypes, buproprion showed subtype selectivity for the α3β4 nicotinic receptor. The application of this methodology to complex mixtures was then carried out by screening aqueous-alcoholic solutions of targeted plant extracts, including Lycopodium clavatum L. (Lycopodiaceae) and Trigonella foenum graecum L. (Fabaceae) against both the α3β4 and α3β4α5 nAChRs. PMID:26774122

  14. Fast simultaneous determination of prominent polyphenols in vegetables and fruits by reversed phase liquid chromatography using a fused-core column.

    PubMed

    Martí, Raúl; Valcárcel, Mercedes; Herrero-Martínez, José Manuel; Cebolla-Cornejo, Jaime; Roselló, Salvador

    2015-02-15

    A reversed-phase high-performance liquid chromatography method with photodiode array detection has been developed enabling the joint determination of 17 prominent flavonoids and phenolic acids in vegetables and fruits. A multi-segmented gradient program using a fused-core column for the separation of several phenolic classes (phenolic acids and flavonoids) has been optimised. The influence of extraction conditions (sample freeze-drying, ultrasound extraction, solvent composition and extraction time) has been also optimised using response surface methodology with tomato samples as a model. Complete recoveries (76-108%) were obtained for the phenolic compounds present in tomato. The developed method provided satisfactory repeatability in terms of peak area (RSD<2.9%) and retention time (RSD<0.2%) both for standards and real samples. Detection limits ranged between 3 and 44μgkg(-1) for the detected polyphenols. This method is recommended for routine analysis of large number of samples typical of production quality systems or plant breeding programs. PMID:25236213

  15. A Method for Simultaneous Determination of 20 Fusarium Toxins in Cereals by High-Resolution Liquid Chromatography-Orbitrap Mass Spectrometry with a Pentafluorophenyl Column

    PubMed Central

    Tamura, Masayoshi; Mochizuki, Naoki; Nagatomi, Yasushi; Harayama, Koichi; Toriba, Akira; Hayakawa, Kazuichi

    2015-01-01

    A high-resolution liquid chromatography-Orbitrap mass spectrometry (LC-Orbitrap MS) method was developed for simultaneous determination of 20 Fusarium toxins (nivalenol, fusarenon-X, deoxynivalenol, 3-acetyl deoxynivalenol, 15-acetyl deoxynivalenol, HT-2 toxin, T-2 toxin, neosolaniol, diacetoxyscirpenol, fumonisin B1, fumonisin B2, fumonisin B3, fumonisin A1, fumonisin A2, fumonisin A3, zearalenone, α-zearalenol, β-zearalenol, α-zearalanol, and β-zearalanol) in cereals. The separation of 20 Fusarium toxins with good peak shapes was achieved using a pentafluorophenyl column, and Orbitrap MS was able to detect accurately from cereal matrix components within ±0.77 ppm. The samples were prepared using a QuEChERS kit for extraction and a multifunctional cartridge for purification. The linearity, repeatability, and recovery of the method were >0.9964, 0.8%–14.7%, and 71%–106%, respectively. Using this method, an analysis of 34 commercially available cereals detected the presence of deoxynivalenol, 15-acetyl deoxynivalenol, fumonisin B1, fumonisin B2, fumonisin B3, fumonisn A1, fumonisin A2, fumonisin A3, and zearalenone in corn samples with high concentration and frequency. Trichothecenes was detected from wheat samples with high frequency; in particular, the concentration of deoxynivalenol was high. Conversely, α-zearalenol, β-zearalenol, α-zearalanol, and β-zearalanol were not detected in any of the samples. PMID:26008230

  16. C18 silica packed capillary columns with monolithic frits prepared with UV light emitting diode: usefulness in nano-liquid chromatography and capillary electrochromatography.

    PubMed

    D'Orazio, Giovanni; Fanali, Salvatore

    2012-04-01

    In this paper the potential of fused silica capillaries packed with RP18 silica particles entrapped with monolithic frits using both nano-liquid chromatography (nano-LC) and capillary electrochromatography (CEC) was investigated. Frits were prepared after removing a short part of the polyimide layer on the capillary wall and irradiating the polymerization mixture with an UV-light emitter diode (LED) at 370 nm. The capillary, was rotated during the polymerization procedure in order to obtain a homogeneous monolith. The distance of the LED from the capillary and the exposure time to UV light were studied in order to obtain frits with good porosity and high robustness. A mixture containing five alkylbenzenes was selected as sample and analyzed by both nano-LC and CEC. The standard mixture was baseline separated with good efficiency in the range 78,000-93,000 and 99,000-113,000 plates/m in nano-LC and CEC, respectively. The columns resulted to be very robust and the prepared monolithic frits allowed working with backpressure as high as 400 bar (nano-LC). In addition high voltages were applied in CEC (25-30 kV) without bubbles formation in absence of pressure assistance during runs. PMID:22189300

  17. Instrumentation: Ion Chromatography.

    ERIC Educational Resources Information Center

    Fritz, James S.

    1987-01-01

    Discusses the importance of ion chromatography in separating and measuring anions. The principles of ion exchange are presented, along with some applications of ion chromatography in industry. Ion chromatography systems are described, as well as ion pair and ion exclusion chromatography, column packings, detectors, and programming. (TW)

  18. Development of a method based on on-line reversed phase liquid chromatography and gas chromatography coupled by means of an adsorption-desorption interface for the analysis of selected chiral volatile compounds in methyl jasmonate treated strawberries.

    PubMed

    de la Peña Moreno, Fernando; Blanch, Gracia Patricia; Flores, Gema; Ruiz Del Castillo, Maria Luisa

    2010-02-12

    A method based on the use of the through oven transfer adsorption-desorption (TOTAD) interface in on-line coupling between reversed phase liquid chromatography and gas chromatography (RPLC-GC) for the determination of chiral volatile compounds was developed. In particular, the method was applied to the study of the influence of methyl jasmonate (MJ) treatment on the production and enantiomeric composition of selected aroma compounds in strawberry. The compounds studied were ethyl 2-methylbutanoate, linalool and 4-hydroxy-2,5-dimethyl-3(2H)-furanone (i.e. furaneol), which were examined on days 3, 6 and 9 after treatment. The method developed resulted in relative standard deviations (RSDs) of 21.6%, 8.1% and 9.8% and limits of detection (LD) of 0.04, 0.07 and 0.02mg/l for ethyl 2-methylbutanoate, linalool and furaneol, respectively. The application of the RPLC-TOTAD-GC method allowed higher levels of ethyl 2-methylbutanoate, linalool and furaneol to be detected, particularly after 9 days of treatment. Besides, MJ demonstrated to affect the enantiomeric distribution of ethyl 2-methylbutanoate. On the contrary, the enantiomeric composition of linalool and furaneol kept constant in both control and MJ-treated strawberries throughout the study. These results are discussed. PMID:19878953

  19. Combined Yamamoto approach for simultaneous estimation of adsorption isotherm and kinetic parameters in ion-exchange chromatography.

    PubMed

    Rüdt, Matthias; Gillet, Florian; Heege, Stefanie; Hitzler, Julian; Kalbfuss, Bernd; Guélat, Bertrand

    2015-09-25

    Application of model-based design is appealing to support the development of protein chromatography in the biopharmaceutical industry. However, the required efforts for parameter estimation are frequently perceived as time-consuming and expensive. In order to speed-up this work, a new parameter estimation approach for modelling ion-exchange chromatography in linear conditions was developed. It aims at reducing the time and protein demand for the model calibration. The method combines the estimation of kinetic and thermodynamic parameters based on the simultaneous variation of the gradient slope and the residence time in a set of five linear gradient elutions. The parameters are estimated from a Yamamoto plot and a gradient-adjusted Van Deemter plot. The combined approach increases the information extracted per experiment compared to the individual methods. As a proof of concept, the combined approach was successfully applied for a monoclonal antibody on a cation-exchanger and for a Fc-fusion protein on an anion-exchange resin. The individual parameter estimations for the mAb confirmed that the new approach maintained the accuracy of the usual Yamamoto and Van Deemter plots. In the second case, offline size-exclusion chromatography was performed in order to estimate the thermodynamic parameters of an impurity (high molecular weight species) simultaneously with the main product. Finally, the parameters obtained from the combined approach were used in a lumped kinetic model to simulate the chromatography runs. The simulated chromatograms obtained for a wide range of gradient lengths and residence times showed only small deviations compared to the experimental data. PMID:26306913

  20. Liquid Chromatography with a Fluorimetric Detection Method for Analysis of Paralytic Shellfish Toxins and Tetrodotoxin Based on a Porous Graphitic Carbon Column

    PubMed Central

    Rey, Veronica; Botana, Ana M.; Alvarez, Mercedes; Antelo, Alvaro; Botana, Luis M.

    2016-01-01

    Paralytic shellfish toxins (PST) traditionally have been analyzed by liquid chromatography with either pre- or post-column derivatization and always with a silica-based stationary phase. This technique resulted in different methods that need more than one run to analyze the toxins. Furthermore, tetrodotoxin (TTX) was recently found in bivalves of northward locations in Europe due to climate change, so it is important to analyze it along with PST because their signs of toxicity are similar in the bioassay. The methods described here detail a new approach to eliminate different runs, by using a new porous graphitic carbon stationary phase. Firstly we describe the separation of 13 PST that belong to different groups, taking into account the side-chains of substituents, in one single run of less than 30 min with good reproducibility. The method was assayed in four shellfish matrices: mussel (Mytillus galloprovincialis), clam (Pecten maximus), scallop (Ruditapes decussatus) and oyster (Ostrea edulis). The results for all of the parameters studied are provided, and the detection limits for the majority of toxins were improved with regard to previous liquid chromatography methods: the lowest values were those for decarbamoyl-gonyautoxin 2 (dcGTX2) and gonyautoxin 2 (GTX2) in mussel (0.0001 mg saxitoxin (STX)·diHCl kg−1 for each toxin), decarbamoyl-saxitoxin (dcSTX) in clam (0.0003 mg STX·diHCl kg−1), N-sulfocarbamoyl-gonyautoxins 2 and 3 (C1 and C2) in scallop (0.0001 mg STX·diHCl kg−1 for each toxin) and dcSTX (0.0003 mg STX·diHCl kg−1 ) in oyster; gonyautoxin 2 (GTX2) showed the highest limit of detection in oyster (0.0366 mg STX·diHCl kg−1). Secondly, we propose a modification of the method for the simultaneous analysis of PST and TTX, with some minor changes in the solvent gradient, although the detection limit for TTX does not allow its use nowadays for regulatory purposes. PMID:27367728

  1. Liquid Chromatography with a Fluorimetric Detection Method for Analysis of Paralytic Shellfish Toxins and Tetrodotoxin Based on a Porous Graphitic Carbon Column.

    PubMed

    Rey, Veronica; Botana, Ana M; Alvarez, Mercedes; Antelo, Alvaro; Botana, Luis M

    2016-01-01

    Paralytic shellfish toxins (PST) traditionally have been analyzed by liquid chromatography with either pre- or post-column derivatization and always with a silica-based stationary phase. This technique resulted in different methods that need more than one run to analyze the toxins. Furthermore, tetrodotoxin (TTX) was recently found in bivalves of northward locations in Europe due to climate change, so it is important to analyze it along with PST because their signs of toxicity are similar in the bioassay. The methods described here detail a new approach to eliminate different runs, by using a new porous graphitic carbon stationary phase. Firstly we describe the separation of 13 PST that belong to different groups, taking into account the side-chains of substituents, in one single run of less than 30 min with good reproducibility. The method was assayed in four shellfish matrices: mussel (Mytillus galloprovincialis), clam (Pecten maximus), scallop (Ruditapes decussatus) and oyster (Ostrea edulis). The results for all of the parameters studied are provided, and the detection limits for the majority of toxins were improved with regard to previous liquid chromatography methods: the lowest values were those for decarbamoyl-gonyautoxin 2 (dcGTX2) and gonyautoxin 2 (GTX2) in mussel (0.0001 mg saxitoxin (STX)·diHCl kg(-1) for each toxin), decarbamoyl-saxitoxin (dcSTX) in clam (0.0003 mg STX·diHCl kg(-1)), N-sulfocarbamoyl-gonyautoxins 2 and 3 (C1 and C2) in scallop (0.0001 mg STX·diHCl kg(-1) for each toxin) and dcSTX (0.0003 mg STX·diHCl kg(-1) ) in oyster; gonyautoxin 2 (GTX2) showed the highest limit of detection in oyster (0.0366 mg STX·diHCl kg(-1)). Secondly, we propose a modification of the method for the simultaneous analysis of PST and TTX, with some minor changes in the solvent gradient, although the detection limit for TTX does not allow its use nowadays for regulatory purposes. PMID:27367728

  2. Minimizing ultraviolet noise due to mis-matches between detector flow cell and post column mobile phase temperatures in supercritical fluid chromatography: effect of flow cell design.

    PubMed

    Berger, Terry A

    2014-10-17

    A mis-match between the post-column mobile phase temperature and the UV detector flow cell temperature can cause significant UV noise in supercritical fluid chromatography (SFC). Deviations as little as 5 °C can increase noise as much as 5 times, making the detector unsuited for trace analysis. Two approaches were used to minimize this noise. When a flow cell was in direct thermal contact (metal on metal) with the detector optical bench, the mobile phase temperature was actively controlled to the measured flow cell temperature, by using one of the heat exchangers (HX) in the column compartment. However, with some older, but still widely used flow cell designs, this required repeated, hourly monitoring of the flow cell temperature and repeated manual adjustment of the heat exchanger temperature, due to thermal drift. Flow cell design had a strong influence on susceptibility to this thermally induced noise. Thermally insulating the flow cell from the optical bench made some cells much less susceptible to such thermally induced noise. Five different flow cells, some insulated, some un-insulated, were evaluated. Most had a truncated conical flow path, but one had a cylindrical flow path. Using either approach, the ASTM noise, with a 10mm, 13 μL conical flow cell, could be optimized to ≈0.007 mAU at 2.5 Hz, in SFC, which is very near the 0.006 mAU manufacturer's specification for HPLC. The insulated version of this flow cell required far less optimization, compared to the un-insulated version. At 150 bar, an experimental 3mm, 2 μL flow cell, with only one side insulated, yielded noise slightly too high (≈0.16-0.18 mAU) for trace analysis, at 80 Hz. However, at 200 bar, noise at 80 Hz was <0.06 mAU, which should allow quantification of a 1 mAU tall trace component with a signal to noise ratio (S/N) >10. Even partially un-insulated, this flow cell design was much less susceptible to thermally induced noise. Further insulating this flow cell design failed to improve

  3. Development and validation of a high-performance liquid chromatography method with post-column derivatization for the detection of aflatoxins in cereals and grains.

    PubMed

    Asghar, Muhammad Asif; Iqbal, Javed; Ahmed, Aftab; Khan, Mobeen Ahmed; Shamsuddin, Zuzzer Ali; Jamil, Khalid

    2016-06-01

    A novel, reliable and rapid high-performance liquid chromatography (HPLC) method with post-column derivatization was developed and validated. The HPLC method was used for the simultaneous determination of aflatoxin B1 (AFB1), B2 (AFB2), G1 (AFG1) and G2 (AFG2) in various cereals and grains. Samples were extracted with 80:20 (v/v) methanol:water and purified using C18 (40-63 μm) solid-phase extraction cartridges. AFs were separated using a LiChroCART-RP-18 (5 μm, 250 × 4.0 mm(2)) column. The mobile phase consisted of methanol:acetonitrile:buffer (17.5:17.5:65 v/v) (pH 7.4) delivered at the flow rate of 1.0 mL min(-1) The fluorescence of each AF was detected at λex = 365 nm and λem = 435 nm. All four AFs were properly resolved within the total run time of 20 min. The established method was extensively validated as a final verification of the method development by the evaluation of selectivity (AFB1, AFB2, AFG1 and AFG2), linearity (R(2) ≥ 0.9994), precision (average SD ≤ 2.79), accuracy (relative mean error ≤ -5.51), robustness (p < 0.0080), ruggedness (p < 0.0100) and average recoveries (89.2-97.8%). The limits of quantification of AFB1, AFB2, AFG1 and AFG2 were 0.080, 0.073, 0.062 and 0.066 ng g(-1), respectively. Finally, the developed method was applied for the analysis of AFs in 45 samples comprising rice (n = 20), wheat (n = 15) and maize (n = 10). The results showed that 65% of rice, 20% of wheat and 80% of maize samples were found contaminated with AFs. Thus, according to the achieved results, it is suggested that the newly developed HPLC method could be effectively applied for the routine analysis of the AFs in different cereals and grains. PMID:25227226

  4. Direct aqueous determination of glyphosate and related compounds by liquid chromatography/tandem mass spectrometry using reversed-phase and weak anion-exchange mixed-mode column.

    PubMed

    Hao, Chunyan; Morse, David; Morra, Franca; Zhao, Xiaoming; Yang, Paul; Nunn, Brian

    2011-08-19

    Analysis of the broad-spectrum herbicide glyphosate and its related compounds is quite challenging. Tedious and time-consuming derivatization is often required for these substances due to their high polarity, high water solubility, low volatility and molecular structure which lacks either a chromophore or fluorophore. A novel liquid chromatography/tandem mass spectrometry (LC/MS-MS) method has been developed for the determination of glyphosate, aminomethylphosphonic acid (AMPA) and glufosinate using a reversed-phase and weak anion-exchange mixed-mode Acclaim® WAX-1 column. Aqueous environmental samples are directly injected and analyzed in 12 min with no sample concentration or derivatization steps. Two multiple reaction monitoring (MRM) channels are monitored in the method for each target compound to achieve true positive identification, and ¹³C, ¹⁵N-glyphosate is used as an internal standard to carry out isotope dilution mass spectrometric (IDMS) measurement for glyphosate. The instrument detection limits (IDLs) for glyphosate, AMPA and glufosinate are 1, 2 and 0.9 μg/L, respectively. Linearity of the detector response with a minimum coefficient of determination (R² value (R² > 0.995) was demonstrated in the range of ∼10 to 10³ μg/L for each analytes. Spiked drinking water, surface water and groundwater samples were analyzed using this method and the average recoveries of analytes in three matrices ranged from 77.0 to 102%, 62.1 to 101%, 66.1 to 93.7% while relative standard deviation ranged from 6.3 to 10.2%, 2.7 to 14.8%, 2.9 to 10.7%, respectively. Factors that may affect method performance, such as metal ions, sample preservation, and storage time, are also discussed. PMID:21752384

  5. Method validation for aflatoxin M1 determination in yoghurt using immunoaffinity column clean-up prior to high-performance liquid chromatography.

    PubMed

    Tabari, Mahsa; Karim, Guity; Ghavami, Mehrdad; Chamani, Mohammad

    2011-08-01

    Yoghurt is a popular dairy product in Iran because of its beneficial influence on human health and nutritional value. Aflatoxin M1 (AFM1) is the metabolite of potential carcinogen aflatoxin B1, which can contaminate milk through the feed and is not eliminated by common processing heat treatment. An analytical method using immunoaffinity column for extraction and a high-performance liquid chromatography (HPLC) for quantification was developed for AFM1 in this study. An HPLC method with fluorimetric detection for the determination of AFM1 in yoghurt milk has been optimized and validated according to Commission Decision BS EN ISO 14501: 2007 by using the conventional validation approach. The procedure for determining selectivity, recovery, precision, decision limit (CCα) and detection capability (CCβ) of the method has been reported. The results of the validation process demonstrate the agreement of the method with the provisions of Commission Regulation 401: 2006:EC. A new HPLC method with fluorescence detection was developed to determine aflatoxin M1. The detection limit was 1 ng/kg for yoghurt. The calibration curve was linear from 0.1 to 3.0 μg l⁻¹ injected. The method includes a preliminary clean-up and the average recoveries determined on three different days at the concentration levels of 0.025, 0.050 and 0.075 μg kg⁻¹ were in the range of 72.57%-86.66% with RSD in the range of 2.56%-8.41%. The interday and interlevel mean recovery value, which has been used to correct routine analysis results, was 80%. The method is rapid, easily automatable and therefore useful for accurate and precise screening of aflatoxin M1 in yoghurt. PMID:21385770

  6. Lewisite Metabolites in Urine by Solid Phase Extraction-Dual Column Reversed-Phase Liquid Chromatography-Isotope Dilution Tandem Mass Spectrometry.

    PubMed

    Palcic, Jason D; Donovan, Stephen F; Jones, Janet S; Flagg, E Lindsay; Salonga, Redentor A; Mock, Walter E; Asirvatham, Victor S

    2016-07-01

    Lewisite (2-chlorovinyldichloroarsine) is a chemical warfare agent developed during World War I. A quantitative method using solid phase extraction (SPE) followed by dual column liquid chromatography (LC)-isotope dilution tandem mass spectrometry (MS-MS) was developed for the determination of (2-chlorovinyl)arsonic acid (CVAOA), a metabolite of Lewisite, in human urine. The sample was treated with hydrogen peroxide to oxidize any (2-chlorovinyl)arsonous acid (CVAA) that remained in the trivalent arsenic oxidation state. There was 1.19% (arsenic purity) of bis-(2-chlorovinyl)arsinic acid (BCVAOA), a minor Lewisite metabolite, in the stock CVAA material. The high-throughput method qualitatively assessed BCVAOA simultaneously utilizing normal-phase silica SPE followed by reversed-phase C18 LC for an orthogonal separation. The chromatographic method results in a 5.8-min cycle time with adequate retention (k' = 2.4) of CVAOA. The mass spectrometer was operated in positive electrospray ionization mode with quantitative m/z 186.9→61.0 and confirmation 186.9→91.0 mass transitions. This selective method demonstrated linearity, accuracy and reproducibility for the clinically relevant calibration range (25-3,200 µg/L as CVAA). The method detection limit was 3.3 µg/L as CVAA from a 10 µL injection. This LC-MS-MS emergency response method has a throughput of >240 samples (2.5 extracted 96-well plates) per day. PMID:27339483

  7. Vitamin D analysis in plasma by high performance liquid chromatography (HPLC) with C(30) reversed phase column and UV detection--easy and acetonitrile-free.

    PubMed

    Hymøller, Lone; Jensen, Søren Krogh

    2011-04-01

    Two physiologically important forms of vitamin D exist: vitamin D(2) and vitamin D(3), which by liver based hydroxylase enzymes are converted to 25-hydroxyvitamin D(2) and 25-hydroxyvitamin D(3), respectively. These hydroxylated metabolites of vitamin D are measured in plasma to assess the vitamin D status of animals and humans. Therefore cheap and reliable analytical methods are very much in demand in nutritional and physiological research. After saponification and extraction of plasma or serum samples the current method uses reverse phase high performance liquid chromatography on a C(30) column and with UV detection at 265nm for quantifying vitamin D(2), vitamin D(3), 25-hydroxyvitamin D(2), and 25-hydroxyvitamin D(3). The method proved versatile with respect to plasma lipid content, sample amount, and plasma concentration of the vitamin D metabolites as it was tested using plasma from six different species: cattle, pigs, poultry, mink, horses, and humans. In cattle plasma recoveries were between 86.6 and 101.0%, within day error between 0.9 and 5.9%, and between day error between 0.2 and 1.7%. However, depending on species and sample amount error percentages varied. When running the method on standard reference material® 972 "Vitamin D in human serum" from the National Institute of Standards and Technology (NIST) (Gaithersburg, USA) the results for 25-hydroxyvitamin D(2) and 25-hydroxyvitamin D(3) concentrations were within the boundaries provided by NIST, reflected by Z-scores between 0.1 and 0.9. PMID:21342692

  8. Simultaneous determination of imidacloprid and carbendazim in water samples by ion chromatography with fluorescence detector and post-column photochemical reactor.

    PubMed

    Subhani, Qamar; Huang, Zhongping; Zhu, Zuoyi; Zhu, Yan

    2013-11-15

    A new analytical method has been developed and validated for the simultaneous determination of pesticides from different classes using ion chromatography-online photochemical derivatisation-fluorescence detector (IC-hv-FD). Fluorimetric detection was performed at λex/λem=332 nm/367 nm for imidacloprid and then detector was set at λex/λem=247 nm/470 nm for carbendazim. The two pesticides imidacloprid and carbendazim were successfully separated isocratically on an IonPac(®) AS11 (250 mm × 4 mm i.d; 13 µm particle size, Dionex) anion-exchange column using 40 mM KOH with 10% (v/v) acetonitrile and pumped at a flow rate of 1.0 mL min(-1). Under the optimized conditions, the limit of detection (LOD, S/N=3) of imidacloprid and carbendazim were 7.8 µg L(-1) and 67 µg L(-1), respectively. The experimental results showed that there was good linearity with a correlation coefficient (r)≥0.9966 over the range of 0.05-10 mg L(-1) for imidacloprid and 0.2-15 mg L(-1) for carbendazim. Good reproducibility with a relative standard deviation (RSD, n=7) less than 4.5%. Finally, the proposed method was applied with satisfactory results to the analysis of these pesticides in ground water, lake water and river water without any pre-treatment of samples. The average spiked recoveries were in the range of 90-104%. PMID:24148383

  9. [Simultaneous determination of glyphosate and glufosinate-ammonium residues in tea by ultra performance liquid chromatography-tandem mass spectrometry coupled with pre-column derivatization].

    PubMed

    Wu, Xiaogang; Chen, Xiaoquan; Xiao, Haijun; Liu, Binqiu

    2015-10-01

    A method was developed for the determination of glyphosate (GLY) and glufosinate-ammonium (GLUF) in tea using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The sample was extracted with ultrapure water and dichloromethane for 30 min under ultrasonication, followed by a simple cleanup with a C18 solid phase extraction (SPE) cartridge, and then GLY and GLUF were derivatized using 9-fluorenylmethoxycarbonyl (FMOC-Cl) in borate buffer for 2 h. The derivatives of GLY and GLUF were separated on a Waters C18 column (50 mm x 2.1 mm, 1.7 μm) in a gradient elution mode, and finally detected with positive electrospray ionization-mass spectrometry (ESI-MS/MS ) in multiple reaction monitoring (MRM) mode. The quantification analysis was performed by external standard method. The method showed a good linearity (r > 0. 990) in the range of 0.003 125-0.1 mg/L. The limits of detection (LODs) of GLY and GLUF were 0.03 mg/kg. At the spiked levels of 0.375, 1.5 and 4.5 mg/kg, the recoveries of GLY and GLUF were 87.37%-99.11% and 81.44% -86.17% respectively, and the relative standard deviations (RSDs) (n = 6) of GLY and GLUF were 0.68%-1.35% and 1.01%-2.33%, respectively. This method is simple, rapid and characterized with acceptable sensitivity and accuracy to meet the requirements for the analysis of GLY and GLUF simultaneously in tea. PMID:26930967

  10. Enrichment of the Glycyrrhizic Acid from Licorice Roots (Glycyrrhiza glabra L.) by Isoelectric Focused Adsorptive Bubble Chromatography

    PubMed Central

    Karaoğul, Eyyüp; Parlar, Perihan; Parlar, Harun; Alma, M. Hakkı

    2016-01-01

    The main aim of this study was to enrich glycyrrhizic acid ammonium salt known as one of the main compounds of licorice roots (Glycyrrhiza glabra L.) by isoelectric focused adsorptive bubble separation technique with different foaming agents. In the experiments, four bubble separation parameters were used with β-lactoglobulin, albumin bovine, and starch (soluble) preferred as foaming agents and without additives. The enrichment of glycyrrhizic acid ammonium salt into the foam was influenced by different additive substances. The results showed that highest enrichment values were obtained from β-lactoglobulin as much as 368.3 times. The lowest enrichment values (5.9 times) were determined for the application without additive. After enrichment, each experiment of glycyrrhizic acid ammonium salt confirmed that these substances could be quantitatively enriched into the collection vessel with isoelectric focused adsorptive bubble separation technique. The transfer of glycyrrhizic acid ammonium salt into the foam from standard solution in the presence of additive was more efficient than aqueous licorice extract. PMID:26949562

  11. DEVELOPMENT AND APPLICATION OF IMMUNOAFFINITY COLUMN CHROMATOGRAPHY AS A CLEANUP METHOD FOR THE DETERMINATION OF ATRAZINE IN COMPLEX ENVIRONMENTAL SAMPLE MEDIA

    EPA Science Inventory

    A rabbit antibody immunoaffinity (IA) column procedure was evaluated as a cleanup method for the determination of atrazine in soil, sediment, and food. Four IA columns were prepared by immobilizing a polyclonal rabbit anti-atrazine antibody solution to HiTrap Sepharose columns. A...

  12. The synthesis and characterization of cellular membrane affinity chromatography columns for the study of human multidrug resistant proteins MRP1, MRP2 and human breast cancer resistant protein BCRP using membranes obtained from Spodoptera frugiperda (Sf9) insect cells

    PubMed Central

    Bhatia, Prateek A.; Moaddel, Ruin; Wainer, Irving W.

    2010-01-01

    CMAC (cellular membrane affinity chromatography columns) have been developed for the study of the human multidrug transporters MRP1, MRP2 and the breast cancer resistance protein (BCRP). The columns were constructed using the immobilized artificial membrane (IAM) stationary phase and cellular membrane fragments obtained from Spodopetra frugiperda (Sf9) cells that had been stably transfected with human Mrp1, Mrp2 or Bcrp c-DNA, using a baculovirus expression system. The resulting CMAC(Sf9MRP1), CMAC(Sf9MRP2) and CMAC(Sf9BCRP) columns and a control column produced using membrane fragments from non-transfected Sf9 cells, CMAC(Sf9), were characterized using frontal affinity chromatography using [3H]-etoposide as the marker ligand and etoposide, benzbromarone and MK571 as the displacers on the CMAC(Sf9MRP1) column, etoposide and furosemide on the CMAC(Sf9MRP2) column and etoposide and fumitremorgin C on the CMAC(Sf9BCPR) column The binding affinities (Ki values) obtained from the chromatographic studies were consistent with the data obtained using non-chromatographic techniques and the results indicate that the immobilized MRP1, MRP2 and BCRP transporters retained their ability to selectively bind known ligands. (S)-verapamil displaced [3H]-etoposide on the CMAC(Sf9MRP1) column to a greater extent than (R)-verapamil and the relative IC50 values of the enantiomers were calculated using the changes in the retention times of the marker. The observed enantioselectivity and calculated IC50 values were consistent with previously reported data. The results indicated that the CMAC(Sf9MRP1), CMAC(Sf9MRP2) and CMAC(Sf9BCRP) columns can be used for the study of binding to the MRP1, MRP2 and BCRP transporters and that membranes from the Sf9 cell line can be used to prepare CMAC columns. This is the first example of the use of membranes from a non-mammalian cell line in an affinity chromatographic system. PMID:20441926

  13. Cost-effective nanoporous Agar-Agar polymer/Nickel powder composite particle for effective bio-products adsorption by expanded bed chromatography.

    PubMed

    Asgari, Setareh; Jahanshahi, Mohsen; Rahimpour, Ahmad

    2014-09-26

    In the present work a novel kind of dense nanoporous composite matrix for expanded bed application has been successfully first prepared with Nickel powder as a densifier and was covered with Agar-Agar layer as a skeleton, through the method of water-in-oil emulsification. Agar-Agar is a porous and inexpensive polymer. In order to fabricate cost-effective adsorbent with favorable qualities Agar-Agar polymer was used. Thereafter, the customized composite particle was modified by pseudo-affinity dye-ligand, Reactive Blue 4 (RB4), aimed at preparing a pseudo-affinity adsorbent (RB4-Agar-Ni) for bioprodut adsorption from aqueous solution. Bovine Serum Albumin (BSA) was selected as a model protein to investigate the adsorption behavior in batchwise and expanded bed chromatography, and the obtained results were evaluated with that of Streamline™ (Amersham-Pharmacia Biotech, Sweden). Spherical appearance and porous structure of composite particles were observed by the optical microscope (OM) and scanning electronic microscope (SEM). The results suggested that the matrices followed the logarithmic normal size distribution with the range of 65-300 μm and average diameter of 126.81-151.47 μm, proper wet density of 1.64-2.78 g/ml, water content of 62.74-34%, porosity of 98-90% and pore size of about 38-130 nm. For better comprehension of the impact of solid phase properties on the performance of the expanded bed, the expansion and hydrodynamic properties of a composite matrix with a series of densities was evaluated and estimated by the retention time distribution method (RTD) in an expanded bed and was compared with that of other matrices. According to obtained results the expansion factors under the same fluid velocity decreased by increasing the matrix density. Moreover, the axial dispersion coefficient (Dax) is the most appropriate parameter for evaluating the stability of expanded bed, on various operating conditions, such as different flow velocity, bed expansion

  14. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of pesticides in water by C-18 solid-phase extraction and capillary-column gas chromatography/mass spectrometry with selected-ion monitoring

    USGS Publications Warehouse

    Zaugg, Steven D.; Sandstrom, Mark W.; Smith, Steven G.; Fehlberg, Kevin M.

    1995-01-01

    A method for the isolation of 41 pesticides and pesticide metabolites in natural-water samples using C-18 solid-phase extraction and determination by capillary-column gas chromatography/mass spectrometry with selected-ion monitoring is described. Water samples are filtered to remove suspended particulate matter and then are pumped through disposable solid-phase extraction columns containing octadecyl-bonded porous silica to extract the pesticides. The columns are dried using carbon dioxide or nitrogen gas, and adsorbed pesticides are removed from the columns by elution with 3.0 milliliters of hexane-isopropanol (3:1). Extracted pesticides are determined by capillary- column gas chromatography/mass spectrometry with selected-ion monitoring of three characteristic ions. The upper concentration limit is 4 micrograms per liter (g/L) for most pesticides, with the exception of widely used corn herbicides--atrazine, alachlor, cyanazine, and metolachlor--which have upper concentration limits of 20 g/L. Single- operator method detection limits in reagent-water samples range from 0.001 to 0.018 g/L. Average short-term single-operator precision in reagent- water samples is 7 percent at the 0.1- and 1.0-g/L levels and 8 percent at the 0.01-g/L level. Mean recoveries in reagent-water samples are 73 percent at the 0.1- and 1.0-g/L levels and 83 percent at the 0.01-g/L level. The estimated holding time for pesticides after extraction on the solid-phase extraction columns was 7 days. An optional on-site extraction procedure allows for samples to be collected and processed at remote sites where it is difficult to ship samples to the laboratory within the recommended pre-extraction holding time.

  15. Improvement of separation efficiencies of anion-exchange chromatography using monolithic silica capillary columns modified with polyacrylates and polymethacrylates containing tertiary amino or quaternary ammonium groups.

    PubMed

    Watanabe, Yuta; Ikegami, Tohru; Horie, Kanta; Hara, Takeshi; Jaafar, Jafariah; Tanaka, Nobuo

    2009-10-30

    Anion-exchange (AEX) columns were prepared by on-column polymerization of acrylates and methacrylates containing tertiary amino or quaternary ammonium groups on monolithic silica in a fused silica capillary modified with anchor groups. The columns provided a plate height (H) of less than 10 microm at optimum linear velocity (u) with keeping their high permeability (K=9-12 x 10(-14) m2). Among seven kinds of AEX columns, a monolithic silica column modified with poly(2-hydroxy-3-(4-methylpiperazin-1-yl)propyl methacrylates) (HMPMA) showed larger retentions and better selectivities for nucleotides and inorganic anions than the others. The HMPMA column of 410 mm length produced 42,000-55,000 theoretical plates (N) at a linear velocity of 0.97 mm/s with a backpressure of 3.8 MPa. The same column could be employed for a fast separation of inorganic anions in 1.8 min at a linear velocity of 5.3 mm/s with a backpressure of 20 MPa. In terms of van Deemter plot and separation impedance, the HMPMA column showed higher performance than a conventional particle-packed AEX column. The HMPMA column showed good recovery of a protein, trypsin inhibitor, and it was applied to the separation of proteins and tryptic digest of bovine serum albumin (BSA) in a gradient elution, to provide better separation compared to a conventional particle-packed AEX column. PMID:19683243

  16. Amino-functionalized mesoporous MCM-41 silica as an efficient adsorbent for water treatment: batch and fixed-bed column adsorption of the nitrate anion

    NASA Astrophysics Data System (ADS)

    Ebrahimi-Gatkash, Mehdi; Younesi, Habibollah; Shahbazi, Afsaneh; Heidari, Ava

    2015-11-01

    In the present study, amino-functionalized Mobil Composite Material No. 41 (MCM-41) was used as an adsorbent to remove nitrate anions from aqueous solutions. Mono-, di- and tri-amino functioned silicas (N-MCM-41, NN-MCM-41 and NNN-MCM-41) were prepared by post-synthesis grafting method. The samples were characterized by means of X-ray powder diffraction, FTIR spectroscopy, thermogravimetric analysis, scanning electron microscopy and nitrogen adsorption-desorption. The effects of pH, initial concentration of anions, and adsorbent loading were examined in batch adsorption system. Results of adsorption experiments showed that the adsorption capacity increased with increasing adsorbent loading and initial anion concentration. It was found that the Langmuir mathematical model indicated better fit to the experimental data than the Freundlich. According to the constants of the Langmuir equation, the maximum adsorption capacity for nitrate anion by N-MCM-41, NN-MCM-41 and NNN-MCM-41 was found to be 31.68, 38.58 and 36.81 mg/g, respectively. The adsorption kinetics were investigated with pseudo-first-order and pseudo-second-order model. Adsorption followed the pseudo-second-order rate kinetics. The coefficients of determination for pseudo-second-order kinetic model are >0.99. For continuous adsorption experiments, NNN-MCM-41 adsorbent was used for the removal of nitrate anion from solutions. Breakthrough curves were investigated at different bed heights, flow rates and initial nitrate anion concentrations. The Thomas and Yan models were utilized to calculate the kinetic parameters and to predict the breakthrough curves of different bed height. Results from this study illustrated the potential utility of these adsorbents for nitrate removal from water solution.

  17. Exposure of unsuspecting workers to deadly atmospheres in below-ground confined spaces and investigation of related whole-air sample composition using adsorption gas chromatography.

    PubMed

    Smith, Philip A; Lockhart, Bonnie; Besser, Brett W; Michalski, Michael A R

    2014-01-01

    Hazardous atmospheres in confined spaces may be obvious when a source of air contamination or oxygen (O2) deficiency is recognized. Such is often the case in general industry settings, especially with work processes which create hazardous atmospheres that may be anticipated. Hazards present in active sewers are also well recognized; but the possibility that O2 deficiency or high airborne contaminant concentrations may exist in new construction sewers or storm drains has been repeatedly ignored with deadly results. Low O2 and high carbon dioxide (CO2) concentrations may exist in new construction manholes that have not yet been connected to an active sewer or drain system, and these concentrations have been shown to vary over time. A recent incident is described where workers repeatedly entered such a confined space without incident, but subsequent entry resulted in a fatality and a near-miss for a co-worker rescuer. Additional cases are discussed, with an emphasis placed on elevated CO2 concentrations as a causative factor. A description is provided for the adsorptive gas chromatography whole-air analysis methodology used to quantitatively determine atmospheric conditions present at this type of fatality site or others after an incident, and for the gas chromatography-mass spectrometry method used to provide confirmation of analyte identity with high certainty. Many types of confined spaces may be encountered in addition to the underground varieties discussed, and many possible atmospheric hazards are possible. The definitive whole-air analysis approach described here may be of use and should be considered to investigate many confined space fatality and near-miss cases, and to better understand the causes of dangerous atmosphere conditions that may arise in confined spaces. PMID:24856640

  18. Sensitivity improvement in hydrophilic interaction chromatography negative mode electrospray ionization mass spectrometry using 2-(2-methoxyethoxy)ethanol as a post-column modifier for non-targeted metabolomics.

    PubMed

    Koch, Wendelin; Forcisi, Sara; Lehmann, Rainer; Schmitt-Kopplin, Philippe

    2014-09-26

    The application of ammonia acetate buffered liquid chromatography (LC) eluents is known to concomitantly lead to ion suppression when electrospray ionization mass spectrometry (ESI-MS) detection is used. In negative ESI mode, post column infusion of 2-(2-methoxyethoxy)ethanol (2-MEE) was shown in the literature to help to compensate this adverse effect occurring in reversed phase liquid chromatography mass spectrometry (RP-LC-MS) analyses. Here a setup of direct infusion and hydrophilic interaction chromatography (HILIC) post-column infusion experiments was established in order to investigate systematically the beneficial effects of 2-MEE. We demonstrate that, 2-MEE can help to improve ESI-MS sensitivity in HILIC too and reveal analyte structure specific behaviors. Our study indicates that 2-MEE especially improves ESI response for small and polar molecules. The ESI response of stable isotope labeled amino acids spiked into biological matrices increases up to 50-fold (i.e. D5-l-glutamic acid) when post column infusion of 2-MEE is applied. A non-targeted analysis of a pooled urine sample via HILIC-ESI-QTOF-MS supports this hypothesis. In direct infusion, the combined application of an ammonia acetate buffered solution together with 2-MEE results in an improved ESI response compared to a non-buffered solution. We observed up to 60-fold increased ESI response of l-lysine. We propose this effect is putatively caused by the formation of smaller ESI droplets and stripping of positive charge from ESI droplets due to evaporation of acetic acid anions. In summary, post-column infusion of 2-MEE especially enhances ESI response of small and polar molecules. Therefore it can be regarded as a valuable add-on in targeted or non-targeted metabolomic HILIC-MS studies since this method sets a focus on this molecule category. PMID:25160955

  19. Gas Chromatography

    NASA Astrophysics Data System (ADS)

    Qian, Michael C.; Peterson, Devin G.; Reineccius, Gary A.

    The first publication on gas chromatography (GC) was in 1952 (1), while the first commercial instruments were manufactured in 1956. James and Martin (1) separated fatty acids by GC, collected the column effluent, and titrated the individual fatty acids for quantitation. GC has advanced greatly since that early work and is now considered to be a mature field that is approaching theoretical limitations.

  20. Detection of ketamine and its metabolites in human hair using an integrated nanoflow liquid chromatography column and electrospray emitter fritted with a single porous 10 μm bead.

    PubMed

    Parkin, Mark C; Longmoore, Alana M; Turfus, Sophie C; Braithwaite, Robin A; Cowan, David A; Elliott, Simon; Kicman, Andrew T

    2013-02-15

    Targeting metabolites incorporated into hair following drug administration is useful for evidential purposes as this approach can aid in differentiating between administration and passive exposure. Greater analytical sensitivity is required than for targeting the parent drug alone. A 20 μm i.d. fused silica capillary column with an integrated electrospray emitter fritted with a single porous 10 μm polymeric bead has been successfully fabricated to facilitate this purpose. The sensitivity gains through the use of these integrated single fritted columns coupled to a nanoelectrospray source (nanoflow-LC nanoESI) over conventional liquid chromatography-tandem mass spectrometry (LC-MS/MS) columns was explored by their application to the detection of ketamine and its phase I metabolites in human hair. Hair was collected from 4 volunteers following the administration of a small oral dose of ketamine (50 mg) and subsequently analysed by the capillary-LC nanoESI approach. The drug and its metabolites were extracted from hair using solid phase extraction following a methanolic wash, pulverisation with a ball mill and acid digestion. From a 50 μL extract, 1 μL was injected and the method provided a limit of detection estimated to be 5 fg on column for ketamine and norketamine and 10 fg for dehydronorketamine. The single porous frit minimises extra column band broadening and offers an alternative fritting approach which reduces the blocking of the electrospray emitter, in comparison with other approaches such as sintering and polymerisation. PMID:23332304

  1. Assay of glyceryl trinitrate, isosorbide dinitrate, and their metabolites in plasma by large-bore capillary column gas-liquid chromatography.

    PubMed

    Booth, B P; Bennett, B M; Brien, J F; Elliott, D A; Marks, G S; McCans, J L; Nakatsu, K

    1990-11-01

    Two large-bore capillary columns, one with dimethyl polysiloxane (HP-1) as the stationary phase and the other with phenyl (50 per cent) methyl (50 per cent) polysiloxane (DB-17), were used to develop gas-liquid chromatographic (GLC) assays for measuring isosorbide dinitrate (ISDN), glyceryl trinitrate (GTN), and their metabolites. ISDN, isosorbide-2-mononitrate (2-ISMN), and isosorbide-5-mononitrate (5-ISMN) in plasma, ranging in concentration from 1 to 300 nM, and GTN, glyceryl-1,2-dinitrate (1,2-GDN), and glyceryl-1,3-dinitrate (1,3-GDN), ranging in concentration from 3 to 60 nM in plasma, were analysed on both columns. GLC analysis yielded baseline resolution of the analytes. The method using the dimethyl polysiloxane column gave a lower limit of detectability for GTN of 0.75 nM (signal/noise (s/n) = 2), and the procedure using the phenyl-methyl column provided a lower limit of detectability for ISDN of 81 pM (s/n = 2). The large-bore column GLC procedures exhibited shorter retention times for both ISDN and GTN than those previously reported for capillary-column assays. The chromatographic resolution of analytes and column efficiency of the large-bore capillary columns were comparable to the results previously found using capillary-column GC. The assays for ISDN and GTN have been shown to be appropriate for pharmacokinetic studies in volunteers and patients. We determined that the HP-1 column is appropriate for the analysis of GTN and metabolites, and the DB-17 column is suitable for analysis of ISDN and its metabolites. We conclude that the use of large-bore capillary columns provides rapid and reliable GLC assays for organic nitrates. PMID:2125512

  2. Determination of co-administrated opioids and benzodiazepines in urine using column-switching solid-phase extraction and liquid chromatography-tandem mass spectrometry.

    PubMed

    Xiong, Lingjuan; Wang, Rong; Liang, Chen; Teng, Xiaomei; Jiang, Fengli; Zeng, Libo; Ye, Haiying; Ni, Chunfang; Yuan, Xiaoliang; Rao, Yulan; Zhang, Yurong

    2015-05-22

    Co-administration of opioids with benzodiazepines is very common around the world. A semi-automated method was developed for the determination of four opioids and two benzodiazepines as well as their metabolites (including glucuronide metabolites) in human urine, based on on-line column-switching-solid-phase extraction (CS-SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The CS-SPE was performed by loading 200μL of urine sample to an Oasis HLB cartridge. Detection was achieved using a LC-MS/MS system equipped with an electrospray ionization source (ESI). For unequivocal identification and confirmation, two selected reaction monitoring transitions were registered for each compound, and no co-elution of interferences was observed at the expected retention time. Significant ion suppressions were observed for most analytes during chromatographic runs, but isotope-labeled internal standards (ISs) were used and found to be useful to compensate for the determination error caused by the matrix effect. The assay's linearity ranged from 1-20ng/mL to 800-1000ng/mL for 23 compounds, except for lorazepam (LOR), whose linearity was in the range of 1-100ng/mL. This method showed to be precise and accurate. The relative standard deviation (RSD) % values of within-run precision, between-run precision and total precision were not greater than 10.4% (n=3), 12.9% (n=5) and 15.1% (n=15), respectively. Accuracy values were in the range of 87.5-110%. Limits of detection (LODs) ranged from 0.2ng/mL to 5ng/mL, and limits of quantification (LOQs) ranged from 1ng/mL to 20ng/mL. The method was applied to the assay of 12 samples from forensic cases, which exemplified the co-administration of benzodiazepines (BZDs) by some heroin abusers. This method was of high sensitivity, selectivity and reliability, minimum sample manipulation, semi-automation, and fairly high throughput (analysis time per sample was 20min). The method developed will be useful for the detection of co

  3. Pre-column incubation followed by fast liquid chromatography analysis for rapid screening of natural methylglyoxal scavengers directly from herbal medicines: case study of Polygonum cuspidatum.

    PubMed

    Tang, Dan; Zhu, Jia-Xiao; Wu, An-Guo; Xu, You-Hua; Duan, Ting-Ting; Zheng, Zhao-Guang; Wang, Ru-Shang; Li, Dan; Zhu, Quan

    2013-04-19

    Methylglyoxal (MGO), a very reactive metabolite of glucose, plays a pivotal role in the pathogenesis of several chronic diseases associated with diabetes, and it has been validated as an attractive target for them. In the present study, a simple and effective method, namely pre-column incubation followed by fast high performance liquid chromatography based on superficially porous particles (shell), coupled with diode array detection and tandem mass spectrometry (UHPLC-DAD-MS(n)), was proposed for rapid and high-throughput screening of natural MGO scavengers directly from the crude extract of Polygonum cuspidatum Sieb. et Zucc, a well-known traditional Chinese medicine which was used for treatment of diabetic complications. The hypothesis is that upon reaction with MGO, the peak areas of components with MGO scavenging potency in the chromatogram will be significantly reduced or disappear, and the structural characterization could be achieved by UHPLC-DAD-MS(n) hyphenated technique. First of all, 12 compounds in P. cuspidatum were well separated within shorter time (~12 min) than previous methods and identified, and two of them, i.e. 3,5,4'-trihydroxystilbene-3-O-(6″-galloyl)-glucoside (3) and emodin-8-O-(6'-malonyl)-glucoside (8) were firstly reported ingredients. After incubation with MGO, four stilbene derivatives were demonstrated to possess potential MGO trapping activities. Furthermore, it was proved that both polydatin (piceid) and resveratrol exhibited effective MGO-trapping capacity by UHPLC analysis, and they could significantly inhibit the formation of advanced glycation end products (AGEs) in the human serum albumin (HSA)-MGO assay, indicating that they were potential candidate agents for delaying and preventing diabetic complications. Additionally, MGO trapping mechanism exploration by UHPLC-MS(n) showed that the positions 2 and 4 of the A ring of stilbene were major active sites for trapping MGO to form both mono- and di-MGO adducts, however, the

  4. Determination of Wastewater Compounds in Sediment and Soil by Pressurized Solvent Extraction, Solid-Phase Extraction, and Capillary-Column Gas Chromatography/Mass Spectrometry

    USGS Publications Warehouse

    Burkhardt, Mark R.; Zaugg, Steven D.; Smith, Steven G.; ReVello, Rhiannon C.

    2006-01-01

    A method for the determination of 61 compounds in environmental sediment and soil samples is described. The method was developed in response to increasing concern over the effects of endocrine-disrupting chemicals in wastewater and wastewater-impacted sediment on aquatic organisms. This method also may be used to evaluate the effects of combined sanitary and storm-sewer overflow on the water and sediment quality of urban streams. Method development focused on the determination of compounds that were chosen on the basis of their endocrine-disrupting potential or toxicity. These compounds include the alkylphenol ethoxylate nonionic surfactants and their degradates, food additives, fragrances, antioxidants, flame retardants, plasticizers, industrial solvents, disinfectants, fecal sterols, polycyclic aromatic hydrocarbons, and high-use domestic pesticides. Sediment and soil samples are extracted using a pressurized solvent extraction system. The compounds of interest are extracted from interfering matrix components by high-pressure water/isopropyl alcohol extraction. The compounds were isolated using disposable solid-phase extraction (SPE) cartridges containing chemically modified polystyrene-divinylbenzene resin. The cartridges were dried with nitrogen gas, and then sorbed compounds were eluted with methylene chloride (80 percent)-diethyl ether (20 percent) through Florisil/sodium sulfate SPE cartridge, and then determined by capillary-column gas chromatography/mass spectrometry. Recoveries in reagent-sand samples fortified at 4 to 72 micrograms averaged 76 percent ?13 percent relative standard deviation for all method compounds. Initial method reporting levels for single-component compounds ranged from 50 to 500 micrograms per kilogram. The concentrations of 20 out of 61 compounds initially will be reported as estimated with the 'E' remark code for one of three reasons: (1) unacceptably low-biased recovery (less than 60 percent) or highly variable method performance

  5. Tartaric acid induced conversion of protopanaxadiol to ginsenosides Rg3 and Rg5 and their in situ recoveries by integrated expanded bed adsorption chromatography.

    PubMed

    Huang, Dan; Li, Yang; Zhang, Min; Ruan, Shengli; Zhang, Hongyang; Wang, Yuerong; Hu, Ping

    2016-08-01

    Panax ginseng has been applied in traditional Chinese medicine for over 2000 years. It is still one of the most popular herbs in recent decades. The prescribed ginseng-containing medicines consist of protopanaxadiol and protopanaxatriol ginsenosides, which are the major constituents of the herb. Minor ginsenosides at low levels in the herb, such as Rg3 and Rg5 , have attracted more rising attention than the major ones. The existing approaches to prepare Rg3 and Rg5 usually rely on either steamed red ginseng as the source or chemical/enzymatic conversion of protopanaxadiol to the targets. It is still highly desirable to effectively achieve such minor components. In this paper, a method integrated extraction of protopanaxadiol and conversion of it to Rg3 and Rg5 has been proposed. Protopanaxadiol was extracted and simultaneously converted to Rg3 and Rg5 by d,l-tartaric acid. The targets were absorbed by resins on expanded bed adsorption chromatography and were then separated from other ginsenosides in different stages. Compared with conventional methods, the developed process has advantages in shortening time consumption and improving the conversion ratio of protopanaxadiol, which is promising in directly achieving Rg3 and Rg5 from P. ginseng. PMID:27288199

  6. Development of a bar adsorptive micro-extraction-large-volume injection-gas chromatography-mass spectrometric method for pharmaceuticals and personal care products in environmental water matrices.

    PubMed

    Neng, N R; Nogueira, J M F

    2012-01-01

    The combination of bar adsorptive micro-extraction using activated carbon (AC) and polystyrene-divinylbenzene copolymer (PS-DVB) sorbent phases, followed by liquid desorption and large-volume injection gas chromatography coupled to mass spectrometry, under selected ion monitoring mode acquisition, was developed for the first time to monitor pharmaceutical and personal care products (PPCPs) in environmental water matrices. Assays performed on 25 mL water samples spiked (100 ng L(-1)) with caffeine, gemfibrozil, triclosan, propranolol, carbamazepine and diazepam, selected as model compounds, yielded recoveries ranging from 74% to 99% under optimised experimental conditions (equilibrium time, 16 h (1,000 rpm); matrix characteristics: pH 5, 5% NaCl for AC phase; LD: methanol/acetonitrile (1:1), 45 min). The analytical performance showed good precision (RSD < 18%), convenient detection limits (5-20 ng L(-1)) and excellent linear dynamic range (20-800 ng L(-1)) with remarkable determination coefficients (r(2) > 0.99), where the PS-DVB sorbent phase showed a much better efficiency. By using the standard addition methodology, the application of the present analytical approach on tap, ground, sea, estuary and wastewater samples allowed very good performance at the trace level. The proposed method proved to be a suitable sorption-based micro-extraction alternative for the analysis of priority pollutants with medium-polar to polar characteristics, showing to be easy to implement, reliable, sensitive and requiring a low sample volume to monitor PPCPs in water matrices. PMID:22076312

  7. "Supermarket Column Chromatography of Leaf Pigments" Revisited: Simple and Ecofriendly Separation of Plant Carotenoids, Chlorophylls, and Flavonoids from Green and Red Leaves

    ERIC Educational Resources Information Center

    Dias, Alice M.; Ferreira, Maria La Salete

    2015-01-01

    A simple and ecofriendly procedure was developed in order to prepare extracts from red and green leaves. This procedure enables the separation of yellow, green, and red band pigments and optimizes the previously reported baking soda "supermarket column". The same extract also led to a novel and colorful potato starch column, which can…

  8. Multi-residue analytical method for the determination of endocrine disruptors and related compounds in river and waste water using dual column liquid chromatography switching system coupled to mass spectrometry.

    PubMed

    Gorga, Marina; Petrovic, Mira; Barceló, Damià

    2013-06-21

    The present study describes a novel, fully automated method, based on column switching using EQuan™ columns for an integrated sample preconcentration and liquid chromatography coupled to tandem mass spectrometry (LC-LC-MS/MS). The method allows the unequivocal identification and quantification of the most relevant environmental endocrine disruptors compounds (EDCs) and compounds suspected to be EDCs, such as natural and synthetic estrogens and their conjugates, antimicrobials, parabens, bisphenol A, alkylphenolic compounds, benzotriazoles, and organophosphorus flame retardants, in surface river water and wastewater samples. Applying this technique, water samples were directly injected into the chromatographic system and the target compounds were concentrated into the loading column. Thereafter, the analytes were transferred into the analytical column for subsequent detection by MS-MS (QqQ). A comparative study employing three types of columns, with different chemical modifications, was performed in order to determine the optimal column that allowed maximum retention and subsequent e