  1. Reliability and Reproducibility of Advanced ECG Parameters in Month-to-Month and Year-to-Year Recordings in Healthy Subjects

    NASA Technical Reports Server (NTRS)

    Starc, Vito; Abughazaleh, Ahmed S.; Schlegel, Todd T.

    2014-01-01

    Advanced resting ECG parameters such the spatial mean QRS-T angle and the QT variability index (QTVI) have important diagnostic and prognostic utility, but their reliability and reproducibility (R&R) are not well characterized. We hypothesized that the spatial QRS-T angle would have relatively higher R&R than parameters such as QTVI that are more responsive to transient changes in the autonomic nervous system. The R&R of several conventional and advanced ECG para-meters were studied via intraclass correlation coefficients (ICCs) and coefficients of variation (CVs) in: (1) 15 supine healthy subjects from month-to-month; (2) 27 supine healthy subjects from year-to-year; and (3) 25 subjects after transition from the supine to the seated posture. As hypothesized, for the spatial mean QRS-T angle and many conventional ECG parameters, ICCs we-re higher, and CVs lower than QTVI, suggesting that the former parameters are more reliable and reproducible.

  2. Human ECG signal parameters estimation during controlled physical activity

    NASA Astrophysics Data System (ADS)

    Maciejewski, Marcin; Surtel, Wojciech; Dzida, Grzegorz

    2015-09-01

    ECG signal parameters are commonly used indicators of human health condition. In most cases the patient should remain stationary during the examination to decrease the influence of muscle artifacts. During physical activity, the noise level increases significantly. The ECG signals were acquired during controlled physical activity on a stationary bicycle and during rest. Afterwards, the signals were processed using a method based on Pan-Tompkins algorithms to estimate their parameters and to test the method.

  3. Accuracy of advanced versus strictly conventional 12-lead ECG for detection and screening of coronary artery disease, left ventricular hypertrophy and left ventricular systolic dysfunction

    PubMed Central

    2010-01-01

    Background Resting conventional 12-lead ECG has low sensitivity for detection of coronary artery disease (CAD) and left ventricular hypertrophy (LVH) and low positive predictive value (PPV) for prediction of left ventricular systolic dysfunction (LVSD). We hypothesized that a ~5-min resting 12-lead advanced ECG test ("A-ECG") that combined results from both the advanced and conventional ECG could more accurately screen for these conditions than strictly conventional ECG. Methods Results from nearly every conventional and advanced resting ECG parameter known from the literature to have diagnostic or predictive value were first retrospectively evaluated in 418 healthy controls and 290 patients with imaging-proven CAD, LVH and/or LVSD. Each ECG parameter was examined for potential inclusion within multi-parameter A-ECG scores derived from multivariate regression models that were designed to optimally screen for disease in general or LVSD in particular. The performance of the best retrospectively-validated A-ECG scores was then compared against that of optimized pooled criteria from the strictly conventional ECG in a test set of 315 additional individuals. Results Compared to optimized pooled criteria from the strictly conventional ECG, a 7-parameter A-ECG score validated in the training set increased the sensitivity of resting ECG for identifying disease in the test set from 78% (72-84%) to 92% (88-96%) (P < 0.0001) while also increasing specificity from 85% (77-91%) to 94% (88-98%) (P < 0.05). In diseased patients, another 5-parameter A-ECG score increased the PPV of ECG for LVSD from 53% (41-65%) to 92% (78-98%) (P < 0.0001) without compromising related negative predictive value. Conclusion Resting 12-lead A-ECG scoring is more accurate than strictly conventional ECG in screening for CAD, LVH and LVSD. PMID:20565702

  4. Deployment of an Advanced Electrocardiographic Analysis (A-ECG) to Detect Cardiovascular Risk in Career Firefighters

    NASA Technical Reports Server (NTRS)

    Dolezal, B. A.; Storer, T. W.; Abrazado, M.; Watne, R.; Schlegel, T. T.; Batalin, M.; Kaiser, W.; Smith, D. L.; Cooper, C. B.

    2011-01-01

    INTRODUCTION: Sudden cardiac death is the leading cause of line of duty death among firefighters, accounting for approximately 45% of fatalities annually. Firefighters perform strenuous muscular work while wearing heavy, encapsulating personal protective equipment in high ambient temperatures, under chaotic and emotionally stressful conditions. These factors can precipitate sudden cardiac events like myocardial infarction, serious dysrhythmias, or cerebrovascular accidents in firefighters with underlying cardiovascular disease. PURPOSE: The purpose of this study was to deploy and then evaluate the contribution of resting advanced ECG (A-ECG) in addition to other screening tools (family history, lipid profiles, and cardiopulmonary exercise tests, XT) in assessment of an individual fs cardiac risk profile. METHODS: Forty-four career firefighters were recruited to perform comprehensive baseline assessments including tests of aerobic performance, fasting lipids and glucose. Five-min resting 12-lead A-ECGs were obtained in a subset of firefighters (n=21) and transmitted over a secure networked system to a NASA physician collaborator. Using myocardial perfusion and other imaging as the gold standard, A-ECG scoring has been proven useful in accurately identifying a number of cardiac pathologies including coronary artery disease (CAD), left ventricular hypertrophy, hypertrophic cardiomyopathy, and non-ischemic and ischemic cardiomyopathy. RESULTS: Subjects f mean (SD) age was 43 (8) years, weight 91 (13) kg, and BMI 28 (3) kg/m2. Fifty-one percent of subjects had .3 cardiovascular risk factors. One subject had ST depression on XT ECG, at least one positive A-ECG score for CAD, and documented CAD based on cardiology referral. While all other subjects, including those with fewer risk factors, higher aerobic fitness, and normal exercise ECGs, were classified as healthy by A-ECG, there was no trend for association between risk factors and any of 20 A-ECG parameters in the

  5. Deployment of an Advanced Electrocardiographic Analysis (A-ECG) to Detect Cardiovascular Risk in Career Firefighters

    NASA Technical Reports Server (NTRS)

    Dolezal, B. A.; Storer, T. W.; Abrazado, M.; Watne, R.; Schlegel, T. T.; Batalin, M.; Kaiser, W.; Smith, D. L.; Cooper, C. B.

    2011-01-01

    2Theta) above which lactate accumulates was 23 (8) ml/kg/min. The chronotropic index, a measure of cardiovascular strain during XT was 35 (8) /L compared with reference values for men of 40 /L. Total cholesterol, LDL-C and HDL-C were 202 (34),126 (29), and 55 (15) mg/dl, respectively. Fifty-one percent of subjects had .3 cardiovascular risk factors, 2 subjects had resting hypertension (BP.140/90), and 23 had pre-hypertension (.120/80 but <140/90). Seven had exaggerated exercise induced hypertension but only one had ST depression on XT ECG, at least one positive A-ECG score for CAD, and documented CAD based on cardiology referral. While all other subjects, including those with fewer risk factors, higher aerobic fitness, and normal exercise ECGs, were classified as healthy by A-ECG, there was no trend for association between risk factors and any of 20 A-ECG parameters in the grouped data. CONCLUSIONS A-ECG screening correctly identified the individual with CAD although there was no trend for A-ECG parameters to distinguish those with elevated BP or multiple risk factors but normal XT ECG. We have demonstrated that a new technology, advanced-ECG, can be introduced for remote firefighter risk assessment. This simple, time and cost-effective approach to risk identification that can be acquired remotely and transmitted securely can detect individuals potentially at risk for line-of-duty death. Additional research is needed to further document its value.

  6. Advanced ECG in 2016: is there more than just a tracing?

    PubMed

    Reichlin, Tobias; Abächerli, Roger; Twerenbold, Raphael; Kühne, Michael; Schaer, Beat; Müller, Christian; Sticherling, Christian; Osswald, Stefan

    2016-01-01

    The 12-lead electrocardiogram (ECG) is the most frequently used technology in clinical cardiology. It is critical for evidence-based management of patients with most cardiovascular conditions, including patients with acute myocardial infarction, suspected chronic cardiac ischaemia, cardiac arrhythmias, heart failure and implantable cardiac devices. In contrast to many other techniques in cardiology, the ECG is simple, small, mobile, universally available and cheap, and therefore particularly attractive. Standard ECG interpretation mainly relies on direct visual assessment. The progress in biomedical computing and signal processing, and the available computational power offer fascinating new options for ECG analysis relevant to all fields of cardiology. Several digital ECG markers and advanced ECG technologies have shown promise in preliminary studies. This article reviews promising novel surface ECG technologies in three different fields. (1) For the detection of myocardial ischaemia and infarction, QRS morphology feature analysis, the analysis of high frequency QRS components (HF-QRS) and methods using vectorcardiography as well as ECG imaging are discussed. (2) For the identification and management of patients with cardiac arrhythmias, methods of advanced P-wave analysis are discussed and the concept of ECG imaging for noninvasive localisation of cardiac arrhythmias is presented. (3) For risk stratification of sudden cardiac death and the selection of patients for medical device therapy, several novel markers including an automated QRS-score for scar quantification, the QRS-T angle or the T-wave peak-to-end-interval are discussed. Despite the existing preliminary data, none of the advanced ECG markers and technologies has yet accomplished the transition into clinical practice. Further refinement of these technologies and broader validation in large unselected patient cohorts are the critical next step needed to facilitate translation of advanced ECG technologies

  7. ECG parameters and exposure to carbon ultrafine particles in young healthy subjects.

    PubMed

    Zareba, Wojciech; Couderc, Jean Philippe; Oberdörster, Günter; Chalupa, David; Cox, Christopher; Huang, Li-Shan; Peters, Annette; Utell, Mark J; Frampton, Mark W

    2009-02-01

    The mechanisms underlying the association between air pollution and cardiovascular morbidity and mortality are unknown. This study aimed to determine whether controlled exposure to elemental carbon ultrafine particles (UFP) affects electrocardiogram (ECG) parameters describing heart rate variability; repolarization duration, morphology, and variability; and changes in the ST segment. Two separate controlled studies (12 subjects each) were performed using a crossover design, in which each subject was exposed to filtered air and carbon UFP for 2 hours. The first protocol involved 2 exposures to air and 10 microg/m(3) (approximately 2 x 10(6) particles/cm(3), count median diameter approximately 25 nm, geometric standard deviation approximately 1.6), at rest. The second protocol included 3 exposures to air, 10, and 25 microg/m(3) UFP (approximately 7 x 10(6) particles/cm(3)), with repeated exercise. Each subject underwent a continuous digital 12-lead ECG Holter recording to analyze the above ECG parameters. Repeated measures analysis of variance (ANOVA) was used to compare tested parameters between exposures. The observed responses to UFP exposure were small and generally not significant, although there were trends indicating an increase in parasympathetic tone, which is most likely also responsible for trends toward ST elevation, blunted QTc shortening, and increased variability of T-wave complexity after exposure to UFP. Recovery from exercise showed a blunted response of the parasympathetic system after exposure to UFP in comparison to air exposure. In conclusion, transient exposure to 10-25 microg/m(3) ultrafine carbon particles does not cause marked changes in ECG-derived parameters in young healthy subjects. However, trends are observed indicating that some subjects might be susceptible to air pollution, with a response involving autonomic modulation of the heart and repolarization of the ventricular myocardium.

  8. EMG/ECG Acquisition System with Online Adjustable Parameters Using ZigBee Wireless Technology

    NASA Astrophysics Data System (ADS)

    Kobayashi, Hiroyuki

    This paper deals with a novel wireless bio-signal acquisition system employing ZigBee wireless technology, which consists of mainly two components, that is, intelligent electrode and data acquisition host. The former is the main topic of this paper. It is put on a subject's body to amplify bio-signal such as EMG or ECG and stream its data at upto 2 ksps. One of the most remarkable feature of the intelligent electrode is that it can change its own parameters including both digital and analog ones on-line. The author describes its design first, then introduces a small, light and low cost implementation of the intelligent electrode named as “VAMPIRE-BAT.” And he show some experimental results to confirm its usability and to estimate its practical performances.

  9. On the feasibility of tilt test outcome early prediction using ECG and pressure parameters

    NASA Astrophysics Data System (ADS)

    Gimeno-Blanes, FJ; Rojo-Álvarez, JL; Caamaño, AJ; Flores-Yepes, JA; García-Alberola, A.

    2011-12-01

    The tilt test is a valuable clinical tool for vasovagal syncope (VVS) diagnostic, and its early prediction from simple ECG and blood pressure-based parameters has widely been studied in the literature. However, no practical system is currently used in the clinical setting for the early prediction of the tilt test outcome. The objectives of this study were (1) to benchmark the early prediction performance of all the previously proposed parameters, when nonlinearly combined; (2) to try to improve this performance with the inclusion of additional information and processing techniques. We analyzed a database of 727 consecutive cases of tilt test. Previously proposed features were measured from heart rate and systolic/diastolic pressure tachograms, in several representative signal segments. We aimed to improve the prediction performance: first, using new nonlinear features (detrended fluctuation analysis and sample entropy); second, using a multivariable nonlinear classifier (support vector machine); and finally, including additional physiological signals (stroke volume). The predictive performance of the nonlinearly combined previously proposed features was limited [area under receiver operating characteristic curve (ROC) 0.57 ± 0.12], especially at the beginning of the test, which is the most clinically relevant period. The improvement with additional available physiological information was limited too. We conclude that the use of a system for tilt test outcome prediction with current knowledge and processing should be considered with caution, and that further effort has to be devoted to understand the mechanisms of VVS.

  10. Effects of noise and filtering on SVD-based morphological parameters of the T wave in the ECG.

    PubMed

    Lehtola, L; Karsikas, M; Koskinen, M; Huikuri, H; Seppanen, T

    2008-01-01

    Singular value decomposition (SVD) based electrocardiogram (ECG) morphology analysis is a novel method in the assessment of subtle abnormalities in the T wave morphology of 12-lead ECG. As various types of noise contaminate the ECG signal and create a bias for the morphological analyses, this study was designed to estimate the effects of noise on the SVD method in an experimental setup. Ideal signals were generated by filtering real ECG signals several times with the Savitzky-Golay filter. Random and real noise samples were superimposed on the ideal signals. The noisy signals were filtered with a power line interference filter combined with the Savitzky-Golay or the wavelet filter. Results show that noise increased both the dipolar and non-dipolar components significantly unless filtering was applied. R-TWR (relative T wave residuum) and A-TWR (absolute T wave residuum) were four to eight times higher in noisy signals. The experiments with patient data demonstrated that certain types of noise may even lead to erroneous classification of patients. Filtering brings the median values closer to the correct ones and decreases significantly the variance of the values of parameters.

  11. Effects of electromagnetic radiation from 3G mobile phone on heart rate, blood pressure and ECG parameters in rats.

    PubMed

    Colak, Cengiz; Parlakpinar, Hakan; Ermis, Necip; Tagluk, Mehmet Emin; Colak, Cemil; Sarihan, Ediz; Dilek, Omer Faruk; Turan, Bahadir; Bakir, Sevtap; Acet, Ahmet

    2012-08-01

    Effects of electromagnetic energy radiated from mobile phones (MPs) on heart is one of the research interests. The current study was designed to investigate the effects of electromagnetic radiation (EMR) from third-generation (3G) MP on the heart rate (HR), blood pressure (BP) and ECG parameters and also to investigate whether exogenous melatonin can exert any protective effect on these parameters. In this study 36 rats were randomized and evenly categorized into 4 groups: group 1 (3G-EMR exposed); group 2 (3G-EMR exposed + melatonin); group 3 (control) and group 4 (control + melatonin). The rats in groups 1 and 2 were exposed to 3G-specific MP's EMR for 20 days (40 min/day; 20 min active (speech position) and 20 min passive (listening position)). Group 2 was also administered with melatonin for 20 days (5 mg/kg daily during the experimental period). ECG signals were recorded from cannulated carotid artery both before and after the experiment, and BP and HR were calculated on 1st, 3rd and 5th min of recordings. ECG signals were processed and statistically evaluated. In our experience, the obtained results did not show significant differences in the BP, HR and ECG parameters among the groups both before and after the experiment. Melatonin, also, did not exhibit any additional effects, neither beneficial nor hazardous, on the heart hemodynamics of rats. Therefore, the strategy (noncontact) of using a 3G MP could be the reason for ineffectiveness; and use of 3G MP, in this perspective, seems to be safer compared to the ones used in close contact with the head. However, further study is needed for standardization of such an assumption.

  12. Simulation methods for the online extraction of ECG parameters under Matlab/Simulink.

    PubMed

    von Wagner, G; Kunzmann, U; Schöchlin, J; Bolz, A

    2002-01-01

    The classification of cardiac pathologies in the human ECG greatly depends on the reliable extraction of characteristic features. This work presents a complete simulation environment for testing ECG classification algorithms under Matlab/Simulink. Evaluation of algorithm performance is undertaken in full compliance with the ANSI/AAMI standards EC38 and EC57, and ranges from beat-to-beat analysis to the comparison of episode markers (e.g., for VT/VF detection algorithms). For testing the quality of waveform boundary detection, our own testing methods have been implemented in compliance with existing literature.

  13. An Improved Method for Discriminating ECG Signals using Typical Nonlinear Dynamic Parameters and Recurrence Quantification Analysis in Cardiac Disease Therapy.

    PubMed

    Tang, M; Chang, C Q; Fung, P C W; Chau, K T; Chan, F H Y

    2005-01-01

    The discrimination of ECG signals using nonlinear dynamic parameters is of crucial importance in the cardiac disease therapy and chaos control for arrhythmia defibrillation in the cardiac system. However, the discrimination results of previous studies using features such as maximal Lyapunov exponent (λmax) and correlation dimension (D2) alone are somewhat limited in recognition rate. In this paper, improved methods for computing λmaxand D2are purposed. Another parameter from recurrence quantification analysis is incorporated to the new multi-feature Bayesian classifier with λmaxand D2so as to improve the discrimination power. Experimental results have verified the prediction using Fisher discriminant that the maximal vertical line length (Vmax) from recurrence quantification analysis is the best to distinguish different ECG classes. Experimental results using the MIT-BIH Arrhythmia Database show improved and excellent overall accuracy (96.3%), average sensitivity (96.3%) and average specificity (98.15%) for discriminating sinus, premature ventricular contraction and ventricular flutter signals.

  14. Construction of a Resting High Fidelity ECG "SuperScore" for Management and Screening of Heart Disease

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.; Delgado, Reynolds; Poulin, Greg; Starc, Vito; Arenare, Brian; Rahman, M. A.

    2006-01-01

    Resting conventional ECG is notoriously insensitive for detecting coronary artery disease (CAD) and only nominally useful in screening for cardiomyopathy (CM). Similarly, conventional exercise stress test ECG is both time- and labor-consuming and its accuracy in identifying CAD is suboptimal for use in population screening. We retrospectively investigated the accuracy of several advanced resting electrocardiographic (ECG) parameters, both alone and in combination, for detecting CAD and cardiomyopathy (CM).

  15. ECG (image)

    MedlinePlus

    ... electrocardiogram (ECG, EKG) is used extensively in the diagnosis of heart disease, ranging from congenital heart disease in infants to myocardial infarction and myocarditis in adults. Several different types of ...

  16. The future of remote ECG monitoring systems

    PubMed Central

    Guo, Shu-Li; Han, Li-Na; Liu, Hong-Wei; Si, Quan-Jin; Kong, De-Feng; Guo, Fu-Su

    2016-01-01

    Remote ECG monitoring systems are becoming commonplace medical devices for remote heart monitoring. In recent years, remote ECG monitoring systems have been applied in the monitoring of various kinds of heart diseases, and the quality of the transmission and reception of the ECG signals during remote process kept advancing. However, there remains accompanying challenges. This report focuses on the three components of the remote ECG monitoring system: patient (the end user), the doctor workstation, and the remote server, reviewing and evaluating the imminent challenges on the wearable systems, packet loss in remote transmission, portable ECG monitoring system, patient ECG data collection system, and ECG signals transmission including real-time processing ST segment, R wave, RR interval and QRS wave, etc. This paper tries to clarify the future developmental strategies of the ECG remote monitoring, which can be helpful in guiding the research and development of remote ECG monitoring. PMID:27582770

  17. Can Functional Cardiac Age be Predicted from ECG in a Normal Healthy Population

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd; Starc, Vito; Leban, Manja; Sinigoj, Petra; Vrhovec, Milos

    2011-01-01

    In a normal healthy population, we desired to determine the most age-dependent conventional and advanced ECG parameters. We hypothesized that changes in several ECG parameters might correlate with age and together reliably characterize the functional age of the heart. Methods: An initial study population of 313 apparently healthy subjects was ultimately reduced to 148 subjects (74 men, 84 women, in the range from 10 to 75 years of age) after exclusion criteria. In all subjects, ECG recordings (resting 5-minute 12-lead high frequency ECG) were evaluated via custom software programs to calculate up to 85 different conventional and advanced ECG parameters including beat-to-beat QT and RR variability, waveform complexity, and signal-averaged, high-frequency and spatial/spatiotemporal ECG parameters. The prediction of functional age was evaluated by multiple linear regression analysis using the best 5 univariate predictors. Results: Ignoring what were ultimately small differences between males and females, the functional age was found to be predicted (R2= 0.69, P < 0.001) from a linear combination of 5 independent variables: QRS elevation in the frontal plane (p<0.001), a new repolarization parameter QTcorr (p<0.001), mean high frequency QRS amplitude (p=0.009), the variability parameter % VLF of RRV (p=0.021) and the P-wave width (p=0.10). Here, QTcorr represents the correlation between the calculated QT and the measured QT signal. Conclusions: In apparently healthy subjects with normal conventional ECGs, functional cardiac age can be estimated by multiple linear regression analysis of mostly advanced ECG results. Because some parameters in the regression formula, such as QTcorr, high frequency QRS amplitude and P-wave width also change with disease in the same direction as with increased age, increased functional age of the heart may reflect subtle age-related pathologies in cardiac electrical function that are usually hidden on conventional ECG.

  18. Assessment of extraction parameters on antioxidant capacity, polyphenol content, epigallocatechin gallate (EGCG), epicatechin gallate (ECG) and iriflophenone 3-C-β-glucoside of agarwood (Aquilaria crassna) young leaves.

    PubMed

    Tay, Pei Yin; Tan, Chin Ping; Abas, Faridah; Yim, Hip Seng; Ho, Chun Wai

    2014-08-14

    The effects of ethanol concentration (0%-100%, v/v), solid-to-solvent ratio (1:10-1:60, w/v) and extraction time (30-180 min) on the extraction of polyphenols from agarwood (Aquilaria crassna) were examined. Total phenolic content (TPC), total flavonoid content (TFC) and total flavanol (TF) assays and HPLC-DAD were used for the determination and quantification of polyphenols, flavanol gallates (epigallocatechin gallate--EGCG and epicatechin gallate--ECG) and a benzophenone (iriflophenone 3-C-β-glucoside) from the crude polyphenol extract (CPE) of A. crassna. 2,2'-Diphenyl-1-picrylhydrazyl (DPPH) radical scavenging activity was used to evaluate the antioxidant capacity of the CPE. Experimental results concluded that ethanol concentration and solid-to-solvent ratio had significant effects (p<0.05) on the yields of polyphenol and antioxidant capacity. Extraction time had an insignificant influence on the recovery of EGCG, ECG and iriflophenone 3-C-β-glucoside, as well as radical scavenging capacity from the CPE. The extraction parameters that exhibited maximum yields were 40% (v/v) ethanol, 1:60 (w/v) for 30 min where the TPC, TFC, TF, DPPH, EGCG, ECG and iriflophenone 3-C-β-glucoside levels achieved were 183.5 mg GAE/g DW, 249.0 mg QE/g DW, 4.9 mg CE/g DW, 93.7%, 29.1 mg EGCG/g DW, 44.3 mg ECG/g DW and 39.9 mg iriflophenone 3-C-β-glucoside/g DW respectively. The IC50 of the CPE was 24.6 mg/L.

  19. Extraction of fetal ECG signal by an improved method using extended Kalman smoother framework from single channel abdominal ECG signal.

    PubMed

    Panigrahy, D; Sahu, P K

    2017-02-16

    This paper proposes a five-stage based methodology to extract the fetal electrocardiogram (FECG) from the single channel abdominal ECG using differential evolution (DE) algorithm, extended Kalman smoother (EKS) and adaptive neuro fuzzy inference system (ANFIS) framework. The heart rate of the fetus can easily be detected after estimation of the fetal ECG signal. The abdominal ECG signal contains fetal ECG signal, maternal ECG component, and noise. To estimate the fetal ECG signal from the abdominal ECG signal, removal of the noise and the maternal ECG component presented in it is necessary. The pre-processing stage is used to remove the noise from the abdominal ECG signal. The EKS framework is used to estimate the maternal ECG signal from the abdominal ECG signal. The optimized parameters of the maternal ECG components are required to develop the state and measurement equation of the EKS framework. These optimized maternal ECG parameters are selected by the differential evolution algorithm. The relationship between the maternal ECG signal and the available maternal ECG component in the abdominal ECG signal is nonlinear. To estimate the actual maternal ECG component present in the abdominal ECG signal and also to recognize this nonlinear relationship the ANFIS is used. Inputs to the ANFIS framework are the output of EKS and the pre-processed abdominal ECG signal. The fetal ECG signal is computed by subtracting the output of ANFIS from the pre-processed abdominal ECG signal. Non-invasive fetal ECG database and set A of 2013 physionet/computing in cardiology challenge database (PCDB) are used for validation of the proposed methodology. The proposed methodology shows a sensitivity of 94.21%, accuracy of 90.66%, and positive predictive value of 96.05% from the non-invasive fetal ECG database. The proposed methodology also shows a sensitivity of 91.47%, accuracy of 84.89%, and positive predictive value of 92.18% from the set A of PCDB.

  20. Tissue Doppler Imaging Combined with Advanced 12-Lead ECG Analysis Might Improve Early Diagnosis of Hypertrophic Cardiomyopathy in Childhood

    NASA Technical Reports Server (NTRS)

    Femlund, E.; Schlegel, T.; Liuba, P.

    2011-01-01

    Optimization of early diagnosis of childhood hypertrophic cardiomyopathy (HCM) is essential in lowering the risk of HCM complications. Standard echocardiography (ECHO) has shown to be less sensitive in this regard. In this study, we sought to assess whether spatial QRS-T angle deviation, which has shown to predict HCM in adults with high sensitivity, and myocardial Tissue Doppler Imaging (TDI) could be additional tools in early diagnosis of HCM in childhood. Methods: Children and adolescents with familial HCM (n=10, median age 16, range 5-27 years), and without obvious hypertrophy but with heredity for HCM (n=12, median age 16, range 4-25 years, HCM or sudden death with autopsy-verified HCM in greater than or equal to 1 first-degree relative, HCM-risk) were additionally investigated with TDI and advanced 12-lead ECG analysis using Cardiax(Registered trademark) (IMED Co Ltd, Budapest, Hungary and Houston). Spatial QRS-T angle (SA) was derived from Kors regression-related transformation. Healthy age-matched controls (n=21) were also studied. All participants underwent thorough clinical examination. Results: Spatial QRS-T angle (Figure/ Panel A) and septal E/Ea ratio (Figure/Panel B) were most increased in HCM group as compared to the HCM-risk and control groups (p less than 0.05). Of note, these 2 variables showed a trend toward higher levels in HCM-risk group than in control group (p=0.05 for E/Ea and 0.06 for QRS/T by ANOVA). In a logistic regression model, increased SA and septal E/Ea ratio appeared to significantly predict both the disease (Chi-square in HCM group: 9 and 5, respectively, p less than 0.05 for both) and the risk for HCM (Chi-square in HCM-risk group: 5 and 4 respectively, p less than 0.05 for both), with further increased predictability level when these 2 variables were combined (Chi-square 10 in HCM group, and 7 in HCM-risk group, p less than 0.01 for both). Conclusions: In this small material, Tissue Doppler Imaging and spatial mean QRS-T angle

  1. Heritability of ECG Biomarkers in the Netherlands Twin Registry Measured from Holter ECGs

    PubMed Central

    Hodkinson, Emily C.; Neijts, Melanie; Sadrieh, Arash; Imtiaz, Mohammad S.; Baumert, Mathias; Subbiah, Rajesh N.; Hayward, Christopher S.; Boomsma, Dorret; Willemsen, Gonneke; Vandenberg, Jamie I.; Hill, Adam P.; De Geus, Eco

    2016-01-01

    Introduction: The resting ECG is the most commonly used tool to assess cardiac electrophysiology. Previous studies have estimated heritability of ECG parameters based on these snapshots of the cardiac electrical activity. In this study we set out to determine whether analysis of heart rate specific data from Holter ECGs allows more complete assessment of the heritability of ECG parameters. Methods and Results: Holter ECGs were recorded from 221 twin pairs and analyzed using a multi-parameter beat binning approach. Heart rate dependent estimates of heritability for QRS duration, QT interval, Tpeak–Tend and Theight were calculated using structural equation modeling. QRS duration is largely determined by environmental factors whereas repolarization is primarily genetically determined. Heritability estimates of both QT interval and Theight were significantly higher when measured from Holter compared to resting ECGs and the heritability estimate of each was heart rate dependent. Analysis of the genetic contribution to correlation between repolarization parameters demonstrated that covariance of individual ECG parameters at different heart rates overlap but at each specific heart rate there was relatively little overlap in the genetic determinants of the different repolarization parameters. Conclusions: Here we present the first study of heritability of repolarization parameters measured from Holter ECGs. Our data demonstrate that higher heritability can be estimated from the Holter than the resting ECG and reveals rate dependence in the genetic—environmental determinants of the ECG that has not previously been tractable. Future applications include deeper dissection of the ECG of participants with inherited cardiac electrical disease. PMID:27199769

  2. The Advanced Photon Source list of parameters

    SciTech Connect

    Bizek, H.M.

    1996-07-01

    The Advanced Photon Source (APS) is a third-generation synchrotron radiation source that stores positrons in a storage ring. The choice of positrons as accelerating particles was motivated by the usual reason: to eliminate the degradation of the beam caused by trapping of positively charged dust particles or ions. The third-generation synchrotron radiation sources are designed to have low beam emittance and many straight sections for insertion devices. The parameter list is comprised of three basic systems: the injection system, the storage ring system, and the experimental facilities system. The components of the injection system are listed according to the causal flow of positrons. Below we briefly list the individual components of the injection system, with the names of people responsible for managing these machines in parentheses: the linac system; electron linac-target-positron linac (Marion White); low energy transport line from linac to the PAR (Michael Borland); positron accumulator ring or PAR (Michael Borland); low energy transport line from PAR to injector synchrotron (Michael Borland); injector synchrotron (Stephen Milton); high energy transport line from injector synchrotron to storage ring (Stephen Milton). The storage ring system, managed by Glenn Decker, uses the Chasman-Green lattice. The APS storage ring, 1104 m in circumference, has 40 periodic sectors. Six are used to house hardware and 34 serve as insertion devices. Another 34 beamlines emit radiation from bending magnets. The experimental facilities system`s parameters include parameters for both an undulator and a wiggler.

  3. Competency in ECG Interpretation Among Medical Students

    PubMed Central

    Kopeć, Grzegorz; Magoń, Wojciech; Hołda, Mateusz; Podolec, Piotr

    2015-01-01

    Background Electrocardiogram (ECG) is commonly used in diagnosis of heart diseases, including many life-threatening disorders. We aimed to assess skills in ECG interpretation among Polish medical students and to analyze the determinants of these skills. Material/Methods Undergraduates from all Polish medical schools were asked to complete a web-based survey containing 18 ECG strips. Questions concerned primary ECG parameters (rate, rhythm, and axis), emergencies, and common ECG abnormalities. Analysis was restricted to students in their clinical years (4th–6th), and students in their preclinical years (1st–3rd) were used as controls. Results We enrolled 536 medical students (females: n=299; 55.8%), aged 19 to 31 (23±1.6) years from all Polish medical schools. Most (72%) were in their clinical years. The overall rate of good response was better in students in years 4th–5th than those in years 1st–3rd (66% vs. 56%; p<0.0001). Competency in ECG interpretation was higher in students who reported ECG self-learning (69% vs. 62%; p<0.0001) but no difference was found between students who attended or did not attend regular ECG classes (66% vs. 66%; p=0.99). On multivariable analysis (p<0.0001), being in clinical years (OR: 2.45 [1.35–4.46] and self-learning (OR: 2.44 [1.46–4.08]) determined competency in ECG interpretation. Conclusions Polish medical students in their clinical years have a good level of competency in interpreting the primary ECG parameters, but their ability to recognize ECG signs of emergencies and common heart abnormalities is low. ECG interpretation skills are determined by self-education but not by attendance at regular ECG classes. Our results indicate qualitative and quantitative deficiencies in teaching ECG interpretation at medical schools. PMID:26541993

  4. Piezoelectric extraction of ECG signal.

    PubMed

    Ahmad, Mahmoud Al

    2016-11-17

    The monitoring and early detection of abnormalities or variations in the cardiac cycle functionality are very critical practices and have significant impact on the prevention of heart diseases and their associated complications. Currently, in the field of biomedical engineering, there is a growing need for devices capable of measuring and monitoring a wide range of cardiac cycle parameters continuously, effectively and on a real-time basis using easily accessible and reusable probes. In this paper, the revolutionary generation and extraction of the corresponding ECG signal using a piezoelectric transducer as alternative for the ECG will be discussed. The piezoelectric transducer pick up the vibrations from the heart beats and convert them into electrical output signals. To this end, piezoelectric and signal processing techniques were employed to extract the ECG corresponding signal from the piezoelectric output voltage signal. The measured electrode based and the extracted piezoelectric based ECG traces are well corroborated. Their peaks amplitudes and locations are well aligned with each other.

  5. Piezoelectric extraction of ECG signal

    NASA Astrophysics Data System (ADS)

    Ahmad, Mahmoud Al

    2016-11-01

    The monitoring and early detection of abnormalities or variations in the cardiac cycle functionality are very critical practices and have significant impact on the prevention of heart diseases and their associated complications. Currently, in the field of biomedical engineering, there is a growing need for devices capable of measuring and monitoring a wide range of cardiac cycle parameters continuously, effectively and on a real-time basis using easily accessible and reusable probes. In this paper, the revolutionary generation and extraction of the corresponding ECG signal using a piezoelectric transducer as alternative for the ECG will be discussed. The piezoelectric transducer pick up the vibrations from the heart beats and convert them into electrical output signals. To this end, piezoelectric and signal processing techniques were employed to extract the ECG corresponding signal from the piezoelectric output voltage signal. The measured electrode based and the extracted piezoelectric based ECG traces are well corroborated. Their peaks amplitudes and locations are well aligned with each other.

  6. A novel algorithm for Bluetooth ECG.

    PubMed

    Pandya, Utpal T; Desai, Uday B

    2012-11-01

    In wireless transmission of ECG, data latency will be significant when battery power level and data transmission distance are not maintained. In applications like home monitoring or personalized care, to overcome the joint effect of previous issues of wireless transmission and other ECG measurement noises, a novel filtering strategy is required. Here, a novel algorithm, identified as peak rejection adaptive sampling modified moving average (PRASMMA) algorithm for wireless ECG is introduced. This algorithm first removes error in bit pattern of received data if occurred in wireless transmission and then removes baseline drift. Afterward, a modified moving average is implemented except in the region of each QRS complexes. The algorithm also sets its filtering parameters according to different sampling rate selected for acquisition of signals. To demonstrate the work, a prototyped Bluetooth-based ECG module is used to capture ECG with different sampling rate and in different position of patient. This module transmits ECG wirelessly to Bluetooth-enabled devices where the PRASMMA algorithm is applied on captured ECG. The performance of PRASMMA algorithm is compared with moving average and S-Golay algorithms visually as well as numerically. The results show that the PRASMMA algorithm can significantly improve the ECG reconstruction by efficiently removing the noise and its use can be extended to any parameters where peaks are importance for diagnostic purpose.

  7. Advanced rotorcraft control using parameter optimization

    NASA Technical Reports Server (NTRS)

    Vansteenwyk, Brett; Ly, Uy-Loi

    1991-01-01

    A reliable algorithm for the evaluation of a quadratic performance index and its gradients with respect to the controller design parameters is presented. The algorithm is part of a design algorithm for an optimal linear dynamic output feedback controller that minimizes a finite time quadratic performance index. The numerical scheme is particularly robust when it is applied to the control law synthesis for systems with densely packed modes and where there is a high likelihood of encountering degeneracies in the closed loop eigensystem. This approach through the use of a accurate Pade series approximation does not require the closed loop system matrix to be diagonalizable. The algorithm has been included in a control design package for optimal robust low order controllers. Usefulness of the proposed numerical algorithm has been demonstrated using numerous practical design cases where degeneracies occur frequently in the closed loop system under an arbitrary controller design initialization and during the numerical search.

  8. [The Study of Advanced Fundamental Parameter Method in EDXRFA].

    PubMed

    Cheng, Feng; Zhang, Qing-xian; Ge, Liang-quan; Gu, Yi; Zeng, Guo-qiang; Luo, Yao-yao; Chen, Shuang; Wang, Lei; Zhao, Jian-kun

    2015-07-01

    The X-ray Fluorescence Analysis(XRFA) is an important and efficient method on the element anylsis and is used in geology, industry and environment protection. But XRFA has a backdraw that the determination limit and accuracy are effected by the matrix of the sample. Now the fundamental parameter is usually used to calculate the content of elements in XRFA, and it is an efficient method if the matrix and net area of characteristic X-ray peak are obtained. But this is invalide in in-stu XRFA. Also the method of net area and the "black material" of sample are the key point of the fundamental parameter method when the Energy Dispersive X-ray Fluorescence Analysis(EDXRFA) method is used in the low content sample. In this paper a advanced fundamental parameter method is discussed. The advanced fundamental parameter method includes the spectra analysis and the fundamental parameter method, which inserts the overlapping peaks separation method into the iteration process of the fundamental parameter method. The advanced method can resolve the net area and the quantitative analysis. The advanced method is used to analyse the standard sample. Compare to the content obtained from the coefficient method, the precision of Cu, Ni and Zn is better than coeffieciency method. The result shows that the advanced method could improve the precision of the EDXRFA, so the advanced method is better than the coefficient method.

  9. High Frequency QRS ECG Accurately Detects Cardiomyopathy

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.; Arenare, Brian; Poulin, Gregory; Moser, Daniel R.; Delgado, Reynolds

    2005-01-01

    High frequency (HF, 150-250 Hz) analysis over the entire QRS interval of the ECG is more sensitive than conventional ECG for detecting myocardial ischemia. However, the accuracy of HF QRS ECG for detecting cardiomyopathy is unknown. We obtained simultaneous resting conventional and HF QRS 12-lead ECGs in 66 patients with cardiomyopathy (EF = 23.2 plus or minus 6.l%, mean plus or minus SD) and in 66 age- and gender-matched healthy controls using PC-based ECG software recently developed at NASA. The single most accurate ECG parameter for detecting cardiomyopathy was an HF QRS morphological score that takes into consideration the total number and severity of reduced amplitude zones (RAZs) present plus the clustering of RAZs together in contiguous leads. This RAZ score had an area under the receiver operator curve (ROC) of 0.91, and was 88% sensitive, 82% specific and 85% accurate for identifying cardiomyopathy at optimum score cut-off of 140 points. Although conventional ECG parameters such as the QRS and QTc intervals were also significantly longer in patients than controls (P less than 0.001, BBBs excluded), these conventional parameters were less accurate (area under the ROC = 0.77 and 0.77, respectively) than HF QRS morphological parameters for identifying underlying cardiomyopathy. The total amplitude of the HF QRS complexes, as measured by summed root mean square voltages (RMSVs), also differed between patients and controls (33.8 plus or minus 11.5 vs. 41.5 plus or minus 13.6 mV, respectively, P less than 0.003), but this parameter was even less accurate in distinguishing the two groups (area under ROC = 0.67) than the HF QRS morphologic and conventional ECG parameters. Diagnostic accuracy was optimal (86%) when the RAZ score from the HF QRS ECG and the QTc interval from the conventional ECG were used simultaneously with cut-offs of greater than or equal to 40 points and greater than or equal to 445 ms, respectively. In conclusion 12-lead HF QRS ECG employing

  10. Piezoelectric extraction of ECG signal

    PubMed Central

    Ahmad, Mahmoud Al

    2016-01-01

    The monitoring and early detection of abnormalities or variations in the cardiac cycle functionality are very critical practices and have significant impact on the prevention of heart diseases and their associated complications. Currently, in the field of biomedical engineering, there is a growing need for devices capable of measuring and monitoring a wide range of cardiac cycle parameters continuously, effectively and on a real-time basis using easily accessible and reusable probes. In this paper, the revolutionary generation and extraction of the corresponding ECG signal using a piezoelectric transducer as alternative for the ECG will be discussed. The piezoelectric transducer pick up the vibrations from the heart beats and convert them into electrical output signals. To this end, piezoelectric and signal processing techniques were employed to extract the ECG corresponding signal from the piezoelectric output voltage signal. The measured electrode based and the extracted piezoelectric based ECG traces are well corroborated. Their peaks amplitudes and locations are well aligned with each other. PMID:27853180

  11. Advancing sensitivity analysis to precisely characterize temporal parameter dominance

    NASA Astrophysics Data System (ADS)

    Guse, Björn; Pfannerstill, Matthias; Strauch, Michael; Reusser, Dominik; Lüdtke, Stefan; Volk, Martin; Gupta, Hoshin; Fohrer, Nicola

    2016-04-01

    Parameter sensitivity analysis is a strategy for detecting dominant model parameters. A temporal sensitivity analysis calculates daily sensitivities of model parameters. This allows a precise characterization of temporal patterns of parameter dominance and an identification of the related discharge conditions. To achieve this goal, the diagnostic information as derived from the temporal parameter sensitivity is advanced by including discharge information in three steps. In a first step, the temporal dynamics are analyzed by means of daily time series of parameter sensitivities. As sensitivity analysis method, we used the Fourier Amplitude Sensitivity Test (FAST) applied directly onto the modelled discharge. Next, the daily sensitivities are analyzed in combination with the flow duration curve (FDC). Through this step, we determine whether high sensitivities of model parameters are related to specific discharges. Finally, parameter sensitivities are separately analyzed for five segments of the FDC and presented as monthly averaged sensitivities. In this way, seasonal patterns of dominant model parameter are provided for each FDC segment. For this methodical approach, we used two contrasting catchments (upland and lowland catchment) to illustrate how parameter dominances change seasonally in different catchments. For all of the FDC segments, the groundwater parameters are dominant in the lowland catchment, while in the upland catchment the controlling parameters change seasonally between parameters from different runoff components. The three methodical steps lead to clear temporal patterns, which represent the typical characteristics of the study catchments. Our methodical approach thus provides a clear idea of how the hydrological dynamics are controlled by model parameters for certain discharge magnitudes during the year. Overall, these three methodical steps precisely characterize model parameters and improve the understanding of process dynamics in hydrological

  12. ECG Sensor Card with Evolving RBP Algorithms for Human Verification

    PubMed Central

    Tseng, Kuo-Kun; Huang, Huang-Nan; Zeng, Fufu; Tu, Shu-Yi

    2015-01-01

    It is known that cardiac and respiratory rhythms in electrocardiograms (ECGs) are highly nonlinear and non-stationary. As a result, most traditional time-domain algorithms are inadequate for characterizing the complex dynamics of the ECG. This paper proposes a new ECG sensor card and a statistical-based ECG algorithm, with the aid of a reduced binary pattern (RBP), with the aim of achieving faster ECG human identity recognition with high accuracy. The proposed algorithm has one advantage that previous ECG algorithms lack—the waveform complex information and de-noising preprocessing can be bypassed; therefore, it is more suitable for non-stationary ECG signals. Experimental results tested on two public ECG databases (MIT-BIH) from MIT University confirm that the proposed scheme is feasible with excellent accuracy, low complexity, and speedy processing. To be more specific, the advanced RBP algorithm achieves high accuracy in human identity recognition and is executed at least nine times faster than previous algorithms. Moreover, based on the test results from a long-term ECG database, the evolving RBP algorithm also demonstrates superior capability in handling long-term and non-stationary ECG signals. PMID:26307995

  13. ECG Sensor Card with Evolving RBP Algorithms for Human Verification.

    PubMed

    Tseng, Kuo-Kun; Huang, Huang-Nan; Zeng, Fufu; Tu, Shu-Yi

    2015-08-21

    It is known that cardiac and respiratory rhythms in electrocardiograms (ECGs) are highly nonlinear and non-stationary. As a result, most traditional time-domain algorithms are inadequate for characterizing the complex dynamics of the ECG. This paper proposes a new ECG sensor card and a statistical-based ECG algorithm, with the aid of a reduced binary pattern (RBP), with the aim of achieving faster ECG human identity recognition with high accuracy. The proposed algorithm has one advantage that previous ECG algorithms lack-the waveform complex information and de-noising preprocessing can be bypassed; therefore, it is more suitable for non-stationary ECG signals. Experimental results tested on two public ECG databases (MIT-BIH) from MIT University confirm that the proposed scheme is feasible with excellent accuracy, low complexity, and speedy processing. To be more specific, the advanced RBP algorithm achieves high accuracy in human identity recognition and is executed at least nine times faster than previous algorithms. Moreover, based on the test results from a long-term ECG database, the evolving RBP algorithm also demonstrates superior capability in handling long-term and non-stationary ECG signals.

  14. Computational Analysis of ECGs

    NASA Astrophysics Data System (ADS)

    Waters, Kevin

    2013-03-01

    Electrocardiogram is among the most powerful methods at present to diagnose heart conditions. Here we employed Fourier transform to analyze Electrocardiograms. The goal of the project is to find a way to isolate different wave signals in ways that today's technology is not capable of. Our focus was on building on a code that is capable of filtering out P, QRS, T waves and noise from the ECG, so we created frequency filters that omitted selected amount of data. We first deconstructed and then constructed the ECG this way to find an optimal code assembly for each ECG wave (P-wave, QRS-wave, T-wave). By focusing on one patient, we succeeded to disentangle the complicated ECG signal. We plan to extend this method to more patients.

  15. Highly Reliable Key Generation from Electrocardiogram (ECG).

    PubMed

    Karimian, Nima; Guo, Zimu; Tehranipoor, Mark; Forte, Domenic

    2016-09-08

    Traditional passwords are inadequate as cryptographic keys, as they are easy to forge and are vulnerable to guessing. Human biometrics have been proposed as a promising alternative due to their intrinsic nature. Electrocardiogram (ECG) is an emerging biometric that is extremely difficult to forge and circumvent, but has not yet been heavily investigated for cryptographic key generation. ECG has challenges with respect to immunity to noise, abnormalities, etc. In this paper, we propose a novel key generation approach that extracts keys from real valued ECG features with high reliability and entropy in mind. Our technique, called interval optimized mapping bit allocation (IOMBA), is applied to normal and abnormal ECG signals under multiple session conditions. We also investigate IOMBA in the context of different feature extraction methods, such as wavelet, discrete cosine transform, etc. to find the best method for feature extraction. Experiments of IOMBA show that 217-bit, 38-bit, and 100-bit keys with 99.9%, 97.4%, and 95% average reliability and high entropy can be extracted from normal, abnormal, and multiple session ECG signals, respectively. By allowing more errors or lowering entropy, key lengths can be further increased by tunable parameters of IOMBA which can be useful in other applications. While IOMBA is demonstrated on ECG, it should be useful for other biometrics as well.

  16. Construction and Use of Resting 12-Lead High Fidelity ECG "SuperScores" in Screening for Heart Disease

    NASA Technical Reports Server (NTRS)

    Schlegel, T. T.; Arenare, B.; Greco, E. C.; DePalma, J. L.; Starc, V.; Nunez, T.; Medina, R.; Jugo, D.; Rahman, M.A.; Delgado, R.

    2007-01-01

    We investigated the accuracy of several conventional and advanced resting ECG parameters for identifying obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. Multiple conventional and advanced ECG parameters were studied for their individual and combined retrospective accuracies in detecting underlying disease, the advanced parameters falling within the following categories: 1) Signal averaged ECG, including 12-lead high frequency QRS (150-250 Hz) plus multiple filtered and unfiltered parameters from the derived Frank leads; 2) 12-lead P, QRS and T-wave morphology via singular value decomposition (SVD) plus signal averaging; 3) Multichannel (12-lead, derived Frank lead, SVD lead) beat-to-beat QT interval variability; 4) Spatial ventricular gradient (and gradient component) variability; and 5) Heart rate variability. Several multiparameter ECG SuperScores were derivable, using stepwise and then generalized additive logistic modeling, that each had 100% retrospective accuracy in detecting underlying CM or CAD. The performance of these same SuperScores was then prospectively evaluated using a test set of another 120 individuals (40 new individuals in each of the CM, CAD and control groups, respectively). All 12-lead ECG SuperScores retrospectively generated for CM continued to perform well in prospectively identifying CM (i.e., areas under the ROC curve greater than 0.95), with one such score (containing just 4 components) maintaining 100% prospective accuracy. SuperScores retrospectively generated for CAD performed somewhat less accurately, with prospective areas under the ROC curve typically in the 0.90-0.95 range. We conclude that resting 12-lead

  17. A nonlinear Bayesian filtering framework for ECG denoising.

    PubMed

    Sameni, Reza; Shamsollahi, Mohammad B; Jutten, Christian; Clifford, Gari D

    2007-12-01

    In this paper, a nonlinear Bayesian filtering framework is proposed for the filtering of single channel noisy electrocardiogram (ECG) recordings. The necessary dynamic models of the ECG are based on a modified nonlinear dynamic model, previously suggested for the generation of a highly realistic synthetic ECG. A modified version of this model is used in several Bayesian filters, including the Extended Kalman Filter, Extended Kalman Smoother, and Unscented Kalman Filter. An automatic parameter selection method is also introduced, to facilitate the adaptation of the model parameters to a vast variety of ECGs. This approach is evaluated on several normal ECGs, by artificially adding white and colored Gaussian noises to visually inspected clean ECG recordings, and studying the SNR and morphology of the filter outputs. The results of the study demonstrate superior results compared with conventional ECG denoising approaches such as bandpass filtering, adaptive filtering, and wavelet denoising, over a wide range of ECG SNRs. The method is also successfully evaluated on real nonstationary muscle artifact. This method may therefore serve as an effective framework for the model-based filtering of noisy ECG recordings.

  18. Advanced lithography parameters extraction by using scatterometry system: part II

    NASA Astrophysics Data System (ADS)

    Zhou, Wenzhan; Hsieh, Michael; Koh, Huipeng; Zhou, Meisheng

    2008-03-01

    As the advanced IC device process shrinks to below sub-micron dimensions (65nm, 45 nm and beyond), the overall CD error budget becomes more and more challenging. The impact of lithography process parameters other than exposure energy and defocus on final CD results cannot be ignored any more. In this paper we continue the development of the advanced lithography parameters model which we presented last year. This year we achieved to decouple 4 lithography parameters: exposure, focus, PEB temperature and laser bandwidth (or z-blur). To improve the accuracy and precision of the model, new scatterometry marks are designed to reduce the pitch dependent accuracy impact of sidewall angle and photoresist height for scatterometry metrology. The concept of this kind of scatterometry mark design is from T.A. Brunner's paper "Process Monitor Gating" [SPIE Vol. 6518, 2007]. With this concept, new scatterometry marks are designed to increase the accuracy of scatterometry measurement without sacrificing the process sensitivity and thus improve the model prediction accuracy.

  19. Advanced Electrocardiography Can Identify Occult Cardiomyopathy in Doberman Pinschers

    NASA Technical Reports Server (NTRS)

    Spiljak, M.; Petric, A. Domanjko; Wilberg, M.; Olsen, L. H.; Stepancic, A.; Schlegel, T. T.; Starc, V.

    2011-01-01

    Recently, multiple advanced resting electrocardiographic (A-ECG) techniques have improved the diagnostic value of short-duration ECG in detection of dilated cardiomyopathy (DCM) in humans. This study investigated whether 12-lead A-ECG recordings could accurately identify the occult phase of DCM in dogs. Short-duration (3-5 min) high-fidelity 12-lead ECG recordings were obtained from 31 privately-owned, clinically healthy Doberman Pinschers (5.4 +/- 1.7 years, 11/20 males/females). Dogs were divided into 2 groups: 1) 19 healthy dogs with normal echocardiographic M-mode measurements: left ventricular internal diameter in diastole (LVIDd . 47mm) and in systole (LVIDs . 38mm) and normal 24-hour ECG recordings (<50 ventricular premature complexes, VPCs); and 2) 12 dogs with occult DCM: 11/12 dogs had increased M-mode measurements (LVIDd . 49mm and/or LVIDs . 40mm) and 5/11 dogs had also >100 VPCs/24h; 1/12 dogs had only abnormal 24-hour ECG recordings (>100 VPCs/24h). ECG recordings were evaluated via custom software programs to calculate multiple parameters of high-frequency (HF) QRS ECG, heart rate variability, QT variability, waveform complexity and 3-D ECG. Student's t-tests determined 19 ECG parameters that were significantly different (P < 0.05) between groups. Principal component factor analysis identified a 5-factor model with 81.4% explained variance. QRS dipolar and non-dipolar voltages, Cornell voltage criteria and QRS waveform residuum were increased significantly (P < 0.05), whereas mean HF QRS amplitude was decreased significantly (P < 0.05) in dogs with occult DCM. For the 5 selected parameters the prediction of occult DCM was performed using a binary logistic regression model with Chi-square tested significance (P < 0.01). ROC analyses showed that the five selected ECG parameters could identify occult ECG with sensitivity 89% and specificity 83%. Results suggest that 12-lead A-ECG might improve diagnostic value of short-duration ECG in earlier detection

  20. A Mixed Approach Of Automated ECG Analysis

    NASA Astrophysics Data System (ADS)

    De, A. K.; Das, J.; Majumder, D. Dutta

    1982-11-01

    ECG is one of the non-invasive and risk-free technique for collecting data about the functional state of the heart. However, all these data-processing techniques can be classified into two basically different approaches -- the first and second generation ECG computer program. Not the opposition, but simbiosis of these two approaches will lead to systems with the highest accuracy. In our paper we are going to describe a mixed approach which will show higher accuracy with lesser amount of computational work. Key Words : Primary features, Patients' parameter matrix, Screening, Logical comparison technique, Multivariate statistical analysis, Mixed approach.

  1. Advanced reactor vessel steels for reactors with supercritical coolant parameters

    NASA Astrophysics Data System (ADS)

    Markov, S. I.; Dub, V. S.; Lebedev, A. G.; Kuleshova, E. A.; Balikoev, A. G.; Makarycheva, E. V.; Tolstykh, D. S.; Frolov, A. S.; Krikun, E. V.

    2016-09-01

    A set of studies, tests, and technological works is performed to design promising high-strength vessel steels for reactors with supercritical coolant parameters. Compositions and technological parameters are proposed for the production of reference steel (within the limits of the grade composition of 15Kh2NMFA-A steel) and high-nickel steel. These steels are characterized by high properties, including metallurgical quality and service and technological parameters. Steel of the reference composition has high (higher by 15%) strength properties, improved viscoplastic properties, and ductile-brittle transition temperature t c of at most-125°C. The strength properties of the high-nickel steel are higher than those of the existing steels by 40-50% and higher than those of advanced foreign steels by 15-20% at ductile-brittle transition temperature t c of at most-165°C. Moreover, the designed steels are characterized by a low content of harmful impurity elements and nonmetallic inclusions, a fine-grained structure, and a low susceptibility to thermal embrittlement.

  2. Hybrid ECG signal conditioner

    NASA Technical Reports Server (NTRS)

    Rinard, G. A.; Steffen, D. A.; Sturm, R. E.

    1979-01-01

    Circuit with high common-mode rejection has ability to filter and amplify accepted analog electrocardiogram (ECG) signals of varying amplitude, shape, and polarity. In addition, low power circuit develops standardized pulses that can be counted and averaged by heart/breath rate processor.

  3. Assessment of systolic thickening with thallium-201 ECG-gated single-photon emission computed tomography: A parameter for local left ventricular function

    SciTech Connect

    Mochizuki, T.; Murase, K.; Fujiwara, Y.; Tanada, S.; Hamamoto, K.; Tauxe, W.N. )

    1991-08-01

    The authors measured left ventricular (LV) systolic thickening expressed as a systolic thickening ratio in 28 patients, using 201Tl ECG-gated SPECT. Five normals, 15 patients with prior myocardial infarction, 5 with hypertrophic cardiomyopathy, and 3 with dilated cardiomyopathy were studied. The systolic thickening ratio was calculated as ((end-systolic--end-diastolic pixel counts) divided by end-diastolic pixel counts), using the circumferential profile technique of both end-diastolic and end-systolic short axial images. Functional images of the systolic thickening ratio were also displayed with the bull's-eye method. The mean systolic thickening ratio thus calculated were as follows: normals, 0.53 {plus minus} 0.05 (mean {plus minus} 1 s.d.); non-transmural prior myocardial infarction, 0.33 {plus minus} 0.09; transmural prior myocardial infarction, 0.14 {plus minus} 0.05; hypertrophic cardiomyopathy in relatively nonhypertrophied areas, 0.56 {plus minus} 0.11; hypertrophic cardiomyopathy in hypertrophied areas, 0.23 {plus minus} 0.07; and dilated cardiomyopathy, 0.19 {plus minus} 0.02. The systolic thickening ratio analysis by gated thallium SPECT offers a unique approach for assessing LV function.

  4. Coating parameters of zirconium carbide on advanced TRISO fuels

    NASA Astrophysics Data System (ADS)

    Dulude, Michael C.

    The feasibility of using very high temperature reactors (VHTR) as part of the next generation of nuclear reactors greatly depends on the tri-structural isotropic (TRISO) fuel particles reliability to retain both gaseous and metallic fission products created in irradiated UO2. Most research devoted to TRISO fuel particles has focused on the characteristics and retention ability of silicon carbide as the main barrier against metallic fission products. This work investigates the deposition parameters necessary to create advanced TRISO particles consisting of the standard SiC TRISO coatings with an additional layer of ZrC applied directly to the UO2 fuel kernel. The additional ZrC layer will act as an oxygen getter to prevent failure mechanisms experienced in TRISO particles. Two failure mechanisms that are of the most concern are the over pressurization of the particles and kernel migration within the TRISO particles. In this study successful ZrC coatings were created and the deposition characteristics were analyzed via optical and SEM microscopy techniques. The ZrC layer was confirmed through XRD analysis. This investigation also reduced U3O8 microspheres to UO2 in an argon atmosphere. The oxygen to metal ratio from the reduced U3O8 was back calculated from oxidation analysis performed with a TGA machine. Once consistent repeatability is shown with coating surrogate zirconia kernels, advanced TRISO coatings will be deposited on the UO2 fuel kernels.

  5. High-frequency ECG

    NASA Technical Reports Server (NTRS)

    Tragardh, Elin; Schlegel, Todd T.

    2006-01-01

    The standard ECG is by convention limited to 0.05-150 Hz, but higher frequencies are also present in the ECG signal. With high-resolution technology, it is possible to record and analyze these higher frequencies. The highest amplitudes of the high-frequency components are found within the QRS complex. In past years, the term "high frequency", "high fidelity", and "wideband electrocardiography" have been used by several investigators to refer to the process of recording ECGs with an extended bandwidth of up to 1000 Hz. Several investigators have tried to analyze HF-QRS with the hope that additional features seen in the QRS complex would provide information enhancing the diagnostic value of the ECG. The development of computerized ECG-recording devices that made it possible to record ECG signals with high resolution in both time and amplitude, as well as better possibilities to store and process the signals digitally, offered new methods for analysis. Different techniques to extract the HF-QRS have been described. Several bandwidths and filter types have been applied for the extraction as well as different signal-averaging techniques for noise reduction. There is no standard method for acquiring and quantifying HF-QRS. The physiological mechanisms underlying HF-QRS are still not fully understood. One theory is that HF-QRS are related to the conduction velocity and the fragmentation of the depolarization wave in the myocardium. In a three-dimensional model of the ventricles with a fractal conduction system it was shown that high numbers of splitting branches are associated with HF-QRS. In this experiment, it was also shown that the changes seen in HF-QRS in patients with myocardial ischemia might be due to the slowing of the conduction velocity in the region of ischemia. This mechanism has been tested by Watanabe et al by infusing sodium channel blockers into the left anterior descending artery in dogs. In their study, 60 unipolar ECGs were recorded from the entire

  6. The programmable ECG simulator.

    PubMed

    Caner, Candan; Engin, Mehmet; Engin, Erkan Zeki

    2008-08-01

    This paper reports the design and development of Digital Signal Controller (DSPIC)-based ECG simulator intended to use in testing, calibration and maintenance of electrocardiographic equipment, and to support biomedical engineering students' education. It generates all 12 healthy ECG derivation signals having a profile that varies with heart rate, amplitude, and different noise contamination in a manner which reflects true in vivo conditions. The heart rate can be set at the range of 30 to 120 beats/minute in four steps. The noise and power line interference effects can be set at the range of 0 to 20 dB in three steps. Since standard commercially available electronic components were used to construct the prototype simulator, the proposed design was also relatively inexpensive to produce.

  7. ECG Beats Classification Using Mixture of Features

    PubMed Central

    Ari, Samit

    2014-01-01

    Classification of electrocardiogram (ECG) signals plays an important role in clinical diagnosis of heart disease. This paper proposes the design of an efficient system for classification of the normal beat (N), ventricular ectopic beat (V), supraventricular ectopic beat (S), fusion beat (F), and unknown beat (Q) using a mixture of features. In this paper, two different feature extraction methods are proposed for classification of ECG beats: (i) S-transform based features along with temporal features and (ii) mixture of ST and WT based features along with temporal features. The extracted feature set is independently classified using multilayer perceptron neural network (MLPNN). The performances are evaluated on several normal and abnormal ECG signals from 44 recordings of the MIT-BIH arrhythmia database. In this work, the performances of three feature extraction techniques with MLP-NN classifier are compared using five classes of ECG beat recommended by AAMI (Association for the Advancement of Medical Instrumentation) standards. The average sensitivity performances of the proposed feature extraction technique for N, S, F, V, and Q are 95.70%, 78.05%, 49.60%, 89.68%, and 33.89%, respectively. The experimental results demonstrate that the proposed feature extraction techniques show better performances compared to other existing features extraction techniques. PMID:27350985

  8. Fetal ECG extraction by extended state Kalman filtering based on single-channel recordings.

    PubMed

    Niknazar, Mohammad; Rivet, Bertrand; Jutten, Christian

    2013-05-01

    In this paper, we present an extended nonlinear Bayesian filtering framework for extracting electrocardiograms (ECGs) from a single channel as encountered in the fetal ECG extraction from abdominal sensor. The recorded signals are modeled as the summation of several ECGs. Each of them is described by a nonlinear dynamic model, previously presented for the generation of a highly realistic synthetic ECG. Consequently, each ECG has a corresponding term in this model and can thus be efficiently discriminated even if the waves overlap in time. The parameter sensitivity analysis for different values of noise level, amplitude, and heart rate ratios between fetal and maternal ECGs shows its effectiveness for a large set of values of these parameters. This framework is also validated on the extractions of fetal ECG from actual abdominal recordings, as well as of actual twin magnetocardiograms.

  9. ECG-derived spatial QRS-T angle is associated with ICD implantation, mortality and heart failure admissions in patients with LV systolic dysfunction

    PubMed Central

    Dugo, Clementina; Cave, Andrew; Zhou, Lifeng; Ayar, Zina; Christiansen, Jonathan; Scott, Tony; Dawson, Liane; Gavin, Andrew

    2017-01-01

    Background Increased spatial QRS-T angle has been shown to predict appropriate implantable cardioverter defibrilIator (ICD) therapy in patients with left ventricular systolic dysfunction (LVSD). We performed a retrospective cohort study in patients with left ventricular ejection fraction (LVEF) 31–40% to assess the relationship between the spatial QRS-T angle and other advanced ECG (A-ECG) as well as echocardiographic metadata, with all-cause mortality or ICD implantation for secondary prevention. Methods 534 patients ≤75 years of age with LVEF 31–40% were identified through an echocardiography reporting database. Digital 12-lead ECGs were retrospectively matched to 295 of these patients, for whom echocardiographic and A-ECG metadata were then generated. Data mining was applied to discover novel ECG and echocardiographic markers of risk. Machine learning was used to develop a model to predict possible outcomes. Results 49 patients (17%) had events, defined as either mortality (n = 16) or ICD implantation for secondary prevention (n = 33). 72 parameters (58 A-ECG, 14 echocardiographic) were univariately different (p<0.05) in those with vs. without events. After adjustment for multiplicity, 24 A-ECG parameters and 3 echocardiographic parameters remained different (p<2x10-3). These included the posterior-to-leftward QRS loop ratio from the derived vectorcardiographic horizontal plane (previously associated with pulmonary artery pressure, p = 2x10-6); spatial mean QRS-T angle (134 vs. 112°, p = 1.6x10-4); various repolarisation vectors; and a previously described 5-parameter A-ECG score for LVSD (p = 4x10-6) that also correlated with echocardiographic global longitudinal strain (R2 = - 0.51, P < 0.0001). A spatial QRS-T angle >110° had an adjusted HR of 3.4 (95% CI 1.6 to 7.4) for secondary ICD implantation or all-cause death and adjusted HR of 4.1 (95% CI 1.2 to 13.9) for future heart failure admission. There was a loss of complexity between A-ECG and

  10. Statistical performance evaluation of ECG transmission using wireless networks.

    PubMed

    Shakhatreh, Walid; Gharaibeh, Khaled; Al-Zaben, Awad

    2013-07-01

    This paper presents simulation of the transmission of biomedical signals (using ECG signal as an example) over wireless networks. Investigation of the effect of channel impairments including SNR, pathloss exponent, path delay and network impairments such as packet loss probability; on the diagnosability of the received ECG signal are presented. The ECG signal is transmitted through a wireless network system composed of two communication protocols; an 802.15.4- ZigBee protocol and an 802.11b protocol. The performance of the transmission is evaluated using higher order statistics parameters such as kurtosis and Negative Entropy in addition to the common techniques such as the PRD, RMS and Cross Correlation.

  11. Digitalis toxicity: ECG vignette.

    PubMed

    Vyas, Aniruddha; Bachani, Neeta; Thakur, Hrishikesh; Lokhandwala, Yash

    2016-09-01

    "Digitalis toxicity, often candidly indexed as poisoning, has plagued the medical profession for over 200 years. The situation qualifies as a professional disgrace on the basis of three items: the situation persists, physicians are often slow to recognize it and, over the decades, writers have been harsh in their denunciation of fellow physicians when toxicity has occurred…." These are the opening remarks of an essay published in 1983 on the 2nd centenary of William Withering's 'magic potion from foxglove's extract for dropsy.' Even today, after many decades, these words appear relevant! We present and discuss an interesting ECG of digitalis toxicity.

  12. High Resolution ECG for Evaluation of Heart Function During Exposure to Subacute Hypobaric Hypoxia

    NASA Technical Reports Server (NTRS)

    Zupet, Petra; Finderle, Zarko; Schlegel, Todd T.; Princi, Tanja; Starc, Vito

    2010-01-01

    High altitude climbing presents a wide spectrum of health risks, including exposure to hypobaric hypoxia. Risks are also typically exacerbated by the difficulty in appropriately monitoring for early signs of organ dysfunction in remote areas. We investigated whether high resolution advanced ECG analysis might be helpful as a non-invasive and easy-to-use tool (e.g., instead of Doppler echocardiography) for evaluating early signs of heart overload in hypobaric hypoxia. Nine non-acclimatized healthy trained alpine rescuers (age 43.7 plus or minus 7.3 years) climbed in four days to the altitude of 4,200 m on Mount Ararat. Five-minute high-resolution 12-lead electrocardiograms (ECGs) were recorded (Cardiosoft) in each subject at rest in the supine position on different days but at the same time of day at four different altitudes: 400 m (reference altitude), 1,700 m, 3,200 m and 4,200 m. Changes in conventional and advanced resting ECG parameters, including in beat-to-beat QT and RR variability, waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG was estimated by calculation of the regression coefficients in independent linear regression models. A p-value of less than 0.05 was adopted as statistically significant. As expected, the RR interval and its variability both decreased with increasing altitude, with trends k = -96 ms/1000 m with p = 0.000 and k = -9 ms/1000 m with p = 0.001, respectively. Significant changes were found in P-wave amplitude, which nearly doubled from the lowest to the highest altitude (k = 41.6 microvolt/1000 m with p = 0.000), and nearly significant changes in P-wave duration (k = 2.9 ms/1000 m with p = 0.059). Changes were less significant or non-significant in other studied parameters including those of waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG. High resolution ECG analysis, particularly of the P wave, shows promise as a tool for monitoring early changes in heart function

  13. Advances in parameter estimation techniques applied to flexible structures

    NASA Technical Reports Server (NTRS)

    Maben, Egbert; Zimmerman, David C.

    1994-01-01

    In this work, various parameter estimation techniques are investigated in the context of structural system identification utilizing distributed parameter models and 'measured' time-domain data. Distributed parameter models are formulated using the PDEMOD software developed by Taylor. Enhancements made to PDEMOD for this work include the following: (1) a Wittrick-Williams based root solving algorithm; (2) a time simulation capability; and (3) various parameter estimation algorithms. The parameter estimations schemes will be contrasted using the NASA Mini-Mast as the focus structure.

  14. Live ECG readings using Google Glass in emergency situations.

    PubMed

    Schaer, Roger; Salamin, Fanny; Jimenez Del Toro, Oscar Alfonso; Atzori, Manfredo; Muller, Henning; Widmer, Antoine

    2015-01-01

    Most sudden cardiac problems require rapid treatment to preserve life. In this regard, electrocardiograms (ECG) shown on vital parameter monitoring systems help medical staff to detect problems. In some situations, such monitoring systems may display information in a less than convenient way for medical staff. For example, vital parameters are displayed on large screens outside the field of view of a surgeon during cardiac surgery. This may lead to losing time and to mistakes when problems occur during cardiac operations. In this paper we present a novel approach to display vital parameters such as the second derivative of the ECG rhythm and heart rate close to the field of view of a surgeon using Google Glass. As a preliminary assessment, we run an experimental study to verify the possibility for medical staff to identify abnormal ECG rhythms from Google Glass. This study compares 6 ECG rhythms readings from a 13.3 inch laptop screen and from the prism of Google Glass. Seven medical residents in internal medicine participated in the study. The preliminary results show that there is no difference between identifying these 6 ECG rhythms from the laptop screen versus Google Glass. Both allow close to perfect identification of the 6 common ECG rhythms. This shows the potential of connected glasses such as Google Glass to be useful in selected medical applications.

  15. Extended Kalman smoother with differential evolution technique for denoising of ECG signal.

    PubMed

    Panigrahy, D; Sahu, P K

    2016-09-01

    Electrocardiogram (ECG) signal gives a lot of information on the physiology of heart. In reality, noise from various sources interfere with the ECG signal. To get the correct information on physiology of the heart, noise cancellation of the ECG signal is required. In this paper, the effectiveness of extended Kalman smoother (EKS) with the differential evolution (DE) technique for noise cancellation of the ECG signal is investigated. DE is used as an automatic parameter selection method for the selection of ten optimized components of the ECG signal, and those are used to create the ECG signal according to the real ECG signal. These parameters are used by the EKS for the development of the state equation and also for initialization of the parameters of EKS. EKS framework is used for denoising the ECG signal from the single channel. The effectiveness of proposed noise cancellation technique has been evaluated by adding white, colored Gaussian noise and real muscle artifact noise at different SNR to some visually clean ECG signals from the MIT-BIH arrhythmia database. The proposed noise cancellation technique of ECG signal shows better signal to noise ratio (SNR) improvement, lesser mean square error (MSE) and percent of distortion (PRD) compared to other well-known methods.

  16. Brugada ECG patterns in athletes.

    PubMed

    Chung, Eugene H

    2015-01-01

    Brugada syndrome is responsible for up to 4% of all sudden cardiac deaths worldwide and up to 20% of sudden cardiac deaths in patients with structurally normal hearts. Heterogeneity of repolarization and depolarization, particularly over the right ventricle and the outflow tract, is responsible for the arrhythmogenic substrate. The coved Type I ECG pattern is considered diagnostic of the syndrome but its prevalence is very low. Distinguishing between a saddle back Type 2 Brugada pattern and one of many "Brugada-like" patterns presents challenges especially in athletes. A number of criteria have been proposed to assess Brugada ECG patterns. Proper precordial ECG lead placement is paramount. This paper reviews Brugada syndrome, Brugada ECG patterns, and recently proposed criteria. Recommendations for evaluating a Brugada ECG pattern are provided.

  17. Advanced Method to Estimate Fuel Slosh Simulation Parameters

    NASA Technical Reports Server (NTRS)

    Schlee, Keith; Gangadharan, Sathya; Ristow, James; Sudermann, James; Walker, Charles; Hubert, Carl

    2005-01-01

    The nutation (wobble) of a spinning spacecraft in the presence of energy dissipation is a well-known problem in dynamics and is of particular concern for space missions. The nutation of a spacecraft spinning about its minor axis typically grows exponentially and the rate of growth is characterized by the Nutation Time Constant (NTC). For launch vehicles using spin-stabilized upper stages, fuel slosh in the spacecraft propellant tanks is usually the primary source of energy dissipation. For analytical prediction of the NTC this fuel slosh is commonly modeled using simple mechanical analogies such as pendulums or rigid rotors coupled to the spacecraft. Identifying model parameter values which adequately represent the sloshing dynamics is the most important step in obtaining an accurate NTC estimate. Analytic determination of the slosh model parameters has met with mixed success and is made even more difficult by the introduction of propellant management devices and elastomeric diaphragms. By subjecting full-sized fuel tanks with actual flight fuel loads to motion similar to that experienced in flight and measuring the forces experienced by the tanks these parameters can be determined experimentally. Currently, the identification of the model parameters is a laborious trial-and-error process in which the equations of motion for the mechanical analog are hand-derived, evaluated, and their results are compared with the experimental results. The proposed research is an effort to automate the process of identifying the parameters of the slosh model using a MATLAB/SimMechanics-based computer simulation of the experimental setup. Different parameter estimation and optimization approaches are evaluated and compared in order to arrive at a reliable and effective parameter identification process. To evaluate each parameter identification approach, a simple one-degree-of-freedom pendulum experiment is constructed and motion is induced using an electric motor. By applying the

  18. Advanced optical techniques for monitoring dosimetric parameters in photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Li, Buhong; Qiu, Zhihai; Huang, Zheng

    2012-12-01

    Photodynamic therapy (PDT) is based on the generation of highly reactive singlet oxygen through interactions of photosensitizer, light and molecular oxygen. PDT has become a clinically approved, minimally invasive therapeutic modality for a wide variety of malignant and nonmalignant diseases. The main dosimetric parameters for predicting the PDT efficacy include the delivered light dose, the quantification and photobleaching of the administrated photosensitizer, the tissue oxygen concentration, the amount of singlet oxygen generation and the resulting biological responses. This review article presents the emerging optical techniques that in use or under development for monitoring dosimetric parameters during PDT treatment. Moreover, the main challenges in developing real-time and noninvasive optical techniques for monitoring dosimetric parameters in PDT will be described.

  19. Noninvasive Fetal ECG analysis

    PubMed Central

    Clifford, Gari D.; Silva, Ikaro; Behar, Joachim; Moody, George B.

    2014-01-01

    Despite the important advances achieved in the field of adult electrocardiography signal processing, the analysis of the non-invasive fetal electrocardiogram (NI-FECG) remains a challenge. Currently no gold standard database exists which provides labelled FECG QRS complexes (and other morphological parameters), and publications rely either on proprietary databases or a very limited set of data recorded from few (or more often, just one) individuals. The PhysioNet/Computing in Cardiology Challenge 2013 enables to tackle some of these limitations by releasing a set of NI-FECG data publicly to the scientific community in order to evaluate signal processing techniques for NI-FECG extraction. The Challenge aim was to encourage development of accurate algorithms for locating QRS complexes and estimating the QT interval in noninvasive FECG signals. Using carefully reviewed reference QRS annotations and QT intervals as a gold standard, based on simultaneous direct FECG when possible, the Challenge was designed to measure and compare the performance of participants’ algorithms objectively. Multiple challenge events were designed to test basic FHR estimation accuracy, as well as accuracy in measurement of inter-beat (RR) and QT intervals needed as a basis for derivation of other FECG features. This editorial reviews the background issues, the design of the Challenge, the key achievements, and the follow-up research generated as a result of the Challenge, published in the concurrent special issue of Physiological Measurement. PMID:25071093

  20. Advances in reactor physics education: Visualization of reactor parameters

    SciTech Connect

    Snoj, L.; Kromar, M.; Zerovnik, G.

    2012-07-01

    Modern computer codes allow detailed neutron transport calculations. In combination with advanced 3D visualization software capable of treating large amounts of data in real time they form a powerful tool that can be used as a convenient modern educational tool for reactor operators, nuclear engineers, students and specialists involved in reactor operation and design. Visualization is applicable not only in education and training, but also as a tool for fuel management, core analysis and irradiation planning. The paper treats the visualization of neutron transport in different moderators, neutron flux and power distributions in two nuclear reactors (TRIGA type research reactor and a typical PWR). The distributions are calculated with MCNP and CORD-2 computer codes and presented using Amira software. (authors)

  1. A view on advances in spheromak understanding and parameters

    SciTech Connect

    Fernandez, J.C.; Chrien, R.E.; Wysocki, F.J.; Mayo, R.M.; Henins, I.

    1990-01-01

    A spheromak is a toroidally-shaped magnetized plasma configuration in which no material (such as coils or vacuum vessels) links the torus, so that the topology of the spheromak boundary is spherical. In the period since the properties of a nearly force-free ({Delta} {times} {rvec B} {approx} {lambda}{rvec B}) spheromak configuration were described using single-fluid MHD theory, and since the first spheromak was formed at the Univ. of Maryland, remarkable theoretical and experimental advances have been made. This paper highlights some of that work. Some of the latest results from the CTX group at Los Alamos are also presented. These include the observation of suprathermal electrons in CTX, evidence by X-ray bursts with photon energies above 1 MeV.

  2. Estimation of Infiltration Parameters and the Irrigation Coefficients with the Surface Irrigation Advance Distance

    PubMed Central

    Beibei, Zhou; Quanjiu, Wang; Shuai, Tan

    2014-01-01

    A theory based on Manning roughness equation, Philip equation and water balance equation was developed which only employed the advance distance in the calculation of the infiltration parameters and irrigation coefficients in both the border irrigation and the surge irrigation. The improved procedure was validated with both the border irrigation and surge irrigation experiments. The main results are shown as follows. Infiltration parameters of the Philip equation could be calculated accurately only using water advance distance in the irrigation process comparing to the experimental data. With the calculated parameters and the water balance equation, the irrigation coefficients were also estimated. The water advance velocity should be measured at about 0.5 m to 1.0 m far from the water advance in the experimental corn fields. PMID:25061664

  3. Non-contact ECG monitoring

    NASA Astrophysics Data System (ADS)

    Smirnov, Alexey S.; Erlikh, Vadim V.; Kodkin, Vladimir L.; Keller, Andrei V.; Epishev, Vitaly V.

    2016-03-01

    The research is dedicated to non-contact methods of electrocardiography. The authors describe the routine of experimental procedure and suggest the approach to solving the problems which arise at indirect signal recording. The paper presents the results of experiments conducted by the authors, covers the flow charts of ECG recorders and reviews the drawbacks of filtering methods used in foreign equivalents.

  4. The evolution of ambulatory ECG monitoring.

    PubMed

    Kennedy, Harold L

    2013-01-01

    Ambulatory Holter electrocardiographic (ECG) monitoring has undergone continuous technological evolution since its invention and development in the 1950s era. With commercial introduction in 1963, there has been an evolution of Holter recorders from 1 channel to 12 channel recorders with increasingly smaller storage media, and there has evolved Holter analysis systems employing increasingly technologically advanced electronics providing a myriad of data displays. This evolution of smaller physical instruments with increasing technological capacity has characterized the development of electronics over the past 50 years. Currently the technology has been focused upon the conventional continuous 24 to 48 hour ambulatory ECG examination, and conventional extended ambulatory monitoring strategies for infrequent to rare arrhythmic events. However, the emergence of the Internet, Wi-Fi, cellular networks, and broad-band transmission has positioned these modalities at the doorway of the digital world. This has led to an adoption of more cost-effective strategies to these conventional methods of performing the examination. As a result, the emergence of the mobile smartphone coupled with this digital capacity is leading to the recent development of Holter smartphone applications. The potential of point-of-care applications utilizing the Holter smartphone and a vast array of new non-invasive sensors is evident in the not too distant future. The Holter smartphone is anticipated to contribute significantly in the future to the field of global health.

  5. Measurement of ventricular function by ECG gating during atrial fibrillation

    SciTech Connect

    Bacharach, S.L.; Green, M.V.; Bonow, R.O.; Findley, S.L.; Ostrow, H.G.; Johnston, G.S.

    1981-03-01

    The assumptions necessary to perform ECG-gated cardiac studies are seemingly not valid for patients in atrial fibrillation (AF). To evaluate the effect of AF on equilibrium gated scintigraphy, beat-by-beat measurements of left-ventricular function were made on seven subjects in AF (mean heart rate 64 bpm), using a high-efficiency nonimaging detector. The parameters evaluated were ejection fraction (EF), time to end-systole (TES), peak rates of ejection and filling (PER,PFR), and their times of occurrence (TPER, TPFR). By averaging together single-beat values of EF, PER, etc., it was possible to determine the true mean values of these parameters. The single-beam mean values were compared with the corresponding parameters calculated from one ECG-gated time-activity curve (TAC) obtained by superimposing all the single-beat TACs irrespective of their length. For this population with slow heart rates, we find that the values for EF, etc., produced from ECG-gated time-activity curves, are very similar to those obtained from the single-beat data. Thus use of ECG gating at low heart rates may allow reliable estimation of average cardiac function even in subjects with AF.

  6. Aerodynamic optimization by simultaneously updating flow variables and design parameters with application to advanced propeller designs

    NASA Technical Reports Server (NTRS)

    Rizk, Magdi H.

    1988-01-01

    A scheme is developed for solving constrained optimization problems in which the objective function and the constraint function are dependent on the solution of the nonlinear flow equations. The scheme updates the design parameter iterative solutions and the flow variable iterative solutions simultaneously. It is applied to an advanced propeller design problem with the Euler equations used as the flow governing equations. The scheme's accuracy, efficiency and sensitivity to the computational parameters are tested.

  7. Wearable ECG Based on Impulse-Radio-Type Human Body Communication.

    PubMed

    Wang, Jianqing; Fujiwara, Takuya; Kato, Taku; Anzai, Daisuke

    2016-09-01

    Human body communication (HBC) provides a promising physical layer for wireless body area networks (BANs) in healthcare and medical applications, because of its low propagation loss and high security characteristics. In this study, we have developed a wearable electrocardiogram (ECG) which employs impulse radio (IR)-type HBC technology for transmitting vital signals on the human body in a wearable BAN scenario. The HBC-based wearable ECG has two excellent features. First, the wideband performance of the IR scheme contributed to very low radiation power so that the transceiver is easy to satisfy the extremely weak radio laws, which does not need a license. This feature can provide big convenience in the use and spread of the wearable ECG. Second, the realization of common use of sensing and transmitting electrodes based on time sharing and capacitive coupling largely simplified the HBC-based ECG structure and contributed to its miniaturization. To verify the validity of the HBC-based ECG, we evaluated its communication performance and ECG acquisition performance. The measured bit error rate, smaller than 10 (-3) at 1.25 Mb/s, showed a good physical layer communication performance, and the acquired ECG waveform and various heart-rate variability parameters in time and frequency domains exhibited good agreement with a commercially available radio-frequency ECG and a Holter ECG. These results sufficiently showed the validity and feasibility of the HBC-based ECG for healthcare applications. This should be the first time to have realized a real-time ECG transmission by using the HBC technology.

  8. [Dynamics of ECG voltage in changing gravity].

    PubMed

    Saltykova, M M; At'kov, O Iu; Capderou, A; Morgun, V V; Gusakov, V A; Kheĭmets, G I; Konovalov, G A; Kondratiuk, L L; Kataev, Iu V; Voronin, L I; Kaspranskiĭ, R R; Vaida, P

    2006-01-01

    Comparative analysis of the QRS voltage response to gravity variations was made using the data about 26 normal human subjects collected in parabolic flights (CNERS-AIRBUS A300 Zero-G, n=23; IL-76MD, n=3) and during the tilt test (head-up tilt at 70 degrees for a min and head-down tilt at-15 degrees for 5 min, n=14). Both the parabolic flights and provocative tilt tests affected R-amplitude in the Z lead. During the hypergravity episodes it was observed in 95% of cases with the mean gain of 16% and maximal--56%. On transition to the horizontal position, the Rz-amplitude showed a rise in each subject (16% on the average). In microgravity, the Rz-amplitude reduced in 95% of the observations. The voltage decline averaged 18% and reached 49% at the maximum. The head-down tilt was conducive to Rz reduction in 78% of observations averaging 2%. Analysis of the ECG records under changing gravity when blood redistribution developed within few seconds not enough for serious metabolic shifts still revealed QRS deviations associated exclusively with the physical factors, i.e., alteration in tissue conduction and distance to electrodes. Our findings can stand in good stead in evaluation of the dynamics of predictive ECG parameters during long-term experiments leading to changes as in tissue conduction, so metabolism.

  9. ECG-based heartbeat classification for arrhythmia detection: A survey.

    PubMed

    Luz, Eduardo José da S; Schwartz, William Robson; Cámara-Chávez, Guillermo; Menotti, David

    2016-04-01

    An electrocardiogram (ECG) measures the electric activity of the heart and has been widely used for detecting heart diseases due to its simplicity and non-invasive nature. By analyzing the electrical signal of each heartbeat, i.e., the combination of action impulse waveforms produced by different specialized cardiac tissues found in the heart, it is possible to detect some of its abnormalities. In the last decades, several works were developed to produce automatic ECG-based heartbeat classification methods. In this work, we survey the current state-of-the-art methods of ECG-based automated abnormalities heartbeat classification by presenting the ECG signal preprocessing, the heartbeat segmentation techniques, the feature description methods and the learning algorithms used. In addition, we describe some of the databases used for evaluation of methods indicated by a well-known standard developed by the Association for the Advancement of Medical Instrumentation (AAMI) and described in ANSI/AAMI EC57:1998/(R)2008 (ANSI/AAMI, 2008). Finally, we discuss limitations and drawbacks of the methods in the literature presenting concluding remarks and future challenges, and also we propose an evaluation process workflow to guide authors in future works.

  10. High Resolution ECG for Evaluation of QT Interval Variability during Exposure to Acute Hypoxia

    NASA Technical Reports Server (NTRS)

    Zupet, P.; Finderle, Z.; Schlegel, Todd T.; Starc, V.

    2010-01-01

    Ventricular repolarization instability as quantified by the index of QT interval variability (QTVI) is one of the best predictors for risk of malignant ventricular arrhythmias and sudden cardiac death. Because it is difficult to appropriately monitor early signs of organ dysfunction at high altitude, we investigated whether high resolution advanced ECG (HR-ECG) analysis might be helpful as a non-invasive and easy-to-use tool for evaluating the risk of cardiac arrhythmias during exposure to acute hypoxia. 19 non-acclimatized healthy trained alpinists (age 37, 8 plus or minus 4,7 years) participated in the study. Five-minute high-resolution 12-lead electrocardiograms (ECGs) were recorded (Cardiosoft) in each subject at rest in the supine position breathing room air and then after breathing 12.5% oxygen for 30 min. For beat-to-beat RR and QT variability, the program of Starc was utilized to derive standard time domain measures such as root mean square of the successive interval difference (rMSSD) of RRV and QTV, the corrected QT interval (QTc) and the QTVI in lead II. Changes were evaluated with paired-samples t-test with p-values less than 0.05 considered statistically significant. As expected, the RR interval and its variability both decreased with increasing altitude, with p = 0.000 and p = 0.005, respectively. Significant increases were found in both the rMSSDQT and the QTVI in lead II, with p = 0.002 and p = 0.003, respectively. There was no change in QTc interval length (p = non significant). QT variability parameters may be useful for evaluating changes in ventricular repolarization caused by hypoxia. These changes might be driven by increases in sympathetic nervous system activity at ventricular level.

  11. Synthetic ECG Generation and Bayesian Filtering Using a Gaussian Wave-Based Dynamical Model

    PubMed Central

    Sayadi, Omid; Shamsollahi, Mohammad B.; Clifford, Gari D.

    2011-01-01

    In this paper, we describe a Gaussian wave-based state space to model the temporal dynamics of electrocardiogram (ECG) signals. It is shown that this model may be effectively used for generating synthetic ECGs as well as separate characteristic waves (CWs) such as the atrial and ventricular complexes. The model uses separate state variables for each CW, i.e. P, QRS and T, and hence is capable of generating individual synthetic CWs as well as realistic ECG signals. The model is therefore useful for generating arrhythmias. Simulations of sinus bradycardia, sinus tachycardia, ventricular flutter, atrial fibrillation, and ventricular tachycardia are presented. In addition, discrete versions of the equations are presented for a model-based Bayesian framework for denoising. This framework, together with an extended Kalman filter (EKF) and extended Kalman smoother (EKS), were used for denoising the ECG for both normal rhythms and arrhythmias. For evaluating the denoising performance the signal-to-noise ratio (SNR) improvement of the filter outputs and clinical parameter stability were studied. The results demonstrate superiority over a wide range of input SNRs, achieving a maximum 12.7 dB improvement. Results indicate that preventing clinically relevant distortion of the ECG is sensitive to the number of model parameters. Models are presented which do not exhibit such distortions. The approach presented in this paper may therefore serve as an effective framework for synthetic ECG generation and model-based filtering of noisy ECG recordings. PMID:20720288

  12. Synthetic ECG generation and Bayesian filtering using a Gaussian wave-based dynamical model.

    PubMed

    Sayadi, Omid; Shamsollahi, Mohammad B; Clifford, Gari D

    2010-10-01

    In this paper, we describe a Gaussian wave-based state space to model the temporal dynamics of electrocardiogram (ECG) signals. It is shown that this model may be effectively used for generating synthetic ECGs as well as separate characteristic waves (CWs) such as the atrial and ventricular complexes. The model uses separate state variables for each CW, i.e. P, QRS and T, and hence is capable of generating individual synthetic CWs as well as realistic ECG signals. The model is therefore useful for generating arrhythmias. Simulations of sinus bradycardia, sinus tachycardia, ventricular flutter, atrial fibrillation and ventricular tachycardia are presented. In addition, discrete versions of the equations are presented for a model-based Bayesian framework for denoising. This framework, together with an extended Kalman filter and extended Kalman smoother, was used for denoising the ECG for both normal rhythms and arrhythmias. For evaluating the denoising performance, the signal-to-noise ratio (SNR) improvement of the filter outputs and clinical parameter stability were studied. The results demonstrate superiority over a wide range of input SNRs, achieving a maximum 12.7 dB improvement. Results indicate that preventing clinically relevant distortion of the ECG is sensitive to the number of model parameters. Models are presented which do not exhibit such distortions. The approach presented in this paper may therefore serve as an effective framework for synthetic ECG generation and model-based filtering of noisy ECG recordings.

  13. Adaptive Fourier decomposition based ECG denoising.

    PubMed

    Wang, Ze; Wan, Feng; Wong, Chi Man; Zhang, Liming

    2016-10-01

    A novel ECG denoising method is proposed based on the adaptive Fourier decomposition (AFD). The AFD decomposes a signal according to its energy distribution, thereby making this algorithm suitable for separating pure ECG signal and noise with overlapping frequency ranges but different energy distributions. A stop criterion for the iterative decomposition process in the AFD is calculated on the basis of the estimated signal-to-noise ratio (SNR) of the noisy signal. The proposed AFD-based method is validated by the synthetic ECG signal using an ECG model and also real ECG signals from the MIT-BIH Arrhythmia Database both with additive Gaussian white noise. Simulation results of the proposed method show better performance on the denoising and the QRS detection in comparing with major ECG denoising schemes based on the wavelet transform, the Stockwell transform, the empirical mode decomposition, and the ensemble empirical mode decomposition.

  14. Mean-shape vector quantizer for ECG signal compression.

    PubMed

    Cárdenas-Barrera, J L; Lorenzo-Ginori, J V

    1999-01-01

    A direct waveform mean-shape vector quantization (MSVQ) is proposed here as an alternative for electrocardiographic (ECG) signal compression. In this method, the mean values for short ECG signal segments are quantized as scalars and compression of the single-lead ECG by average beat substraction and residual differencing their waveshapes coded through a vector quantizer. An entropy encoder is applied to both, mean and vector codes, to further increase compression without degrading the quality of the reconstructed signals. In this paper, the fundamentals of MSVQ are discussed, along with various parameters specifications such as duration of signal segments, the wordlength of the mean-value quantization and the size of the vector codebook. The method is assessed through percent-residual-difference measures on reconstructed signals, whereas its computational complexity is analyzed considering its real-time implementation. As a result, MSVQ has been found to be an efficient compression method, leading to high compression ratios (CR's) while maintaining a low level of waveform distortion and, consequently, preserving the main clinically interesting features of the ECG signals. CR's in excess of 39 have been achieved, yielding low data rates of about 140 bps. This compression factor makes this technique especially attractive in the area of ambulatory monitoring.

  15. Bronchodilator response of advanced lung function parameters depending on COPD severity

    PubMed Central

    Jarenbäck, Linnea; Eriksson, Göran; Peterson, Stefan; Ankerst, Jaro; Bjermer, Leif; Tufvesson, Ellen

    2016-01-01

    Background COPD is defined as partly irreversible airflow obstruction. The response pattern of bronchodilators has not been followed in advanced lung function parameters. Purpose The aim of this study was to investigate bronchodilator response pattern in advanced lung function parameters in a continuous fashion along forced expiratory volume in 1 second (FEV1) percent predicted (%p) in COPD patients and controls. Patients and methods Eighty-one smokers/ex-smokers (41 controls and 40 COPD) performed spirometry, body plethysmography, impulse oscillometry and single-breath helium dilution carbon monoxide diffusion at baseline, after salbutamol inhalation and then after an additional inhalation of ipratropium. Results Most pulmonary function parameters showed a linear increase in response to decreased FEV1%p. The subjects were divided into groups of FEV1%p <65 and >65, and the findings from continuous analysis were verified. The exceptions to this linear response were inspiratory capacity (IC), forced vital capacity (FVC), FEV1/FVC and expiratory resistance (Rex), which showed a segmented response relationship to FEV1%p. IC and FVC, with break points (BP) of 57 and 58 FEV1%p respectively, showed no response above, but an incresed slope below the BP. In addition, in patients with FEV1%p <65 and >65, response of FEV1%p did not correlate to response of volume parameters. Conclusion Response of several advanced lung function parameters differs depending on patients’ baseline FEV1%p, and specifically response of volume parameters is most pronounced in COPD patients with FEV1%p <65. Volume and resistance responses do not follow the flow response measured with FEV1 and may thus be used as a complement to FEV1 reversibility to identify flow, volume and resistance responders. PMID:27932874

  16. Real-time ECG emulation: a multiple dipole model for electrocardiography simulation.

    PubMed

    Abkai, Ciamak; Hesser, Jürgen

    2009-01-01

    A new model for describing electrocardiography (ECG) is presented, which is based on multiple dipoles compared to standard single dipole approaches in vector electrocardiography. The multiple dipole parameters are derived from real data (e.g. four dipoles from 12-channel ECG) by solving the backward problem of ECG numerically. Results are transformed to a waveform description based on Gaussian mixture for every dimension of each dipole. These compact parameterized descriptors are used for a very realistic real-time simulation applying the forward solution of the proposed model.

  17. Novel technical solutions for wireless ECG transmission & analysis in the age of the internet cloud.

    PubMed

    Al-Zaiti, Salah S; Shusterman, Vladimir; Carey, Mary G

    2013-01-01

    Current guidelines recommend early reperfusion therapy for ST-elevation myocardial infarction (STEMI) within 90 min of first medical encounter. Telecardiology entails the use of advanced communication technologies to transmit the prehospital 12-lead electrocardiogram (ECG) to offsite cardiologists for early triage to the cath lab; which has been shown to dramatically reduce door-to-balloon time and total mortality. However, hospitals often find adopting ECG transmission technologies very challenging. The current review identifies seven major technical challenges of prehospital ECG transmission, including: paramedics inconvenience and transport delay; signal noise and interpretation errors; equipment malfunction and transmission failure; reliability of mobile phone networks; lack of compliance with the standards of digital ECG formats; poor integration with electronic medical records; and costly hardware and software pre-requisite installation. Current and potential solutions to address each of these technical challenges are discussed in details and include: automated ECG transmission protocols; annotatable waveform-based ECGs; optimal routing solutions; and the use of cloud computing systems rather than vendor-specific processing stations. Nevertheless, strategies to monitor transmission effectiveness and patient outcomes are essential to sustain initial gains of implementing ECG transmission technologies.

  18. A Review of Fetal ECG Signal Processing; Issues and Promising Directions

    PubMed Central

    Sameni, Reza; Clifford, Gari D.

    2010-01-01

    The field of electrocardiography has been in existence for over a century, yet despite significant advances in adult clinical electrocardiography, signal processing techniques and fast digital processors, the analysis of fetal ECGs is still in its infancy. This is, partly due to a lack of availability of gold standard databases, partly due to the relatively low signal-to-noise ratio of the fetal ECG compared to the maternal ECG (caused by the various media between the fetal heart and the measuring electrodes, and the fact that the fetal heart is simply smaller), and in part, due to the less complete clinical knowledge concerning fetal cardiac function and development. In this paper we review a range of promising recording and signal processing techniques for fetal ECG analysis that have been developed over the last forty years, and discuss both their shortcomings and advantages. Before doing so, however, we review fetal cardiac development, and the etiology of the fetal ECG. A selection of relevant models for the fetal/maternal ECG mixture is also discussed. In light of current understanding of the fetal ECG, we then attempt to justify recommendations for promising future directions in signal processing, and database creation. PMID:21614148

  19. Assurance of energy efficiency and data security for ECG transmission in BASNs.

    PubMed

    Ma, Tao; Shrestha, Pradhumna Lal; Hempel, Michael; Peng, Dongming; Sharif, Hamid; Chen, Hsiao-Hwa

    2012-04-01

    With the technological advancement in body area sensor networks (BASNs), low cost high quality electrocardiographic (ECG) diagnosis systems have become important equipment for healthcare service providers. However, energy consumption and data security with ECG systems in BASNs are still two major challenges to tackle. In this study, we investigate the properties of compressed ECG data for energy saving as an effort to devise a selective encryption mechanism and a two-rate unequal error protection (UEP) scheme. The proposed selective encryption mechanism provides a simple and yet effective security solution for an ECG sensor-based communication platform, where only one percent of data is encrypted without compromising ECG data security. This part of the encrypted data is essential to ECG data quality due to its unequally important contribution to distortion reduction. The two-rate UEP scheme achieves a significant additional energy saving due to its unequal investment of communication energy to the outcomes of the selective encryption, and thus, it maintains a high ECG data transmission quality. Our results show the improvements in communication energy saving of about 40%, and demonstrate a higher transmission quality and security measured in terms of wavelet-based weighted percent root-mean-squared difference.

  20. A comprehensive survey of wearable and wireless ECG monitoring systems for older adults.

    PubMed

    Baig, Mirza Mansoor; Gholamhosseini, Hamid; Connolly, Martin J

    2013-05-01

    Wearable health monitoring is an emerging technology for continuous monitoring of vital signs including the electrocardiogram (ECG). This signal is widely adopted to diagnose and assess major health risks and chronic cardiac diseases. This paper focuses on reviewing wearable ECG monitoring systems in the form of wireless, mobile and remote technologies related to older adults. Furthermore, the efficiency, user acceptability, strategies and recommendations on improving current ECG monitoring systems with an overview of the design and modelling are presented. In this paper, over 120 ECG monitoring systems were reviewed and classified into smart wearable, wireless, mobile ECG monitoring systems with related signal processing algorithms. The results of the review suggest that most research in wearable ECG monitoring systems focus on the older adults and this technology has been adopted in aged care facilitates. Moreover, it is shown that how mobile telemedicine systems have evolved and how advances in wearable wireless textile-based systems could ensure better quality of healthcare delivery. The main drawbacks of deployed ECG monitoring systems including imposed limitations on patients, short battery life, lack of user acceptability and medical professional's feedback, and lack of security and privacy of essential data have been also discussed.

  1. ECG manifestations in acute organophosphorus poisoning.

    PubMed

    Paul, Uttam Kumar; Bhattacharyya, Anup Kumar

    2012-02-01

    A cross-sectional study was conducted to evaluate the electrocardiographic changes in 107 patients of acute organophosphorus poisoning admitted at casuality ward of MGM Medical College, Kisanganj from June 2007 to June 2010. Electrocardiographic changes were recorded before the administration of atropine. Prolonged Q-Tc interval was the commonest ECG abnormality, found in 67 patients (62.6%), followed by sinus tachycardia in 36 patients (33.6%). Sinus bradycardia was found in 33 patients (30.8%). Elevation of ST segment was seen in 27 patients (25.2%). T wave inversion was seen in 21 patients (19.6%). First-degree heart block (P-R interval >0.20 seconds) occurred in 9 cases (8.4%). Atrial fibrillation was seen in 5 patients (4.6%). Ventricular tachycardia was seen in 6 cases (5.6%) and ventricular premature complexes in 3 patients (2.8%). Of these 6 cases of ventricular tachycardia 1 responded to intravenous lignocaine, and the other 5 developed ventricular fibrillation leading to death despite other resuscitative measures. All the electrocardiographical abnormalities returned to normal before the patients were discharged. Seventeen patients died. The cause of death was ventricular fibrillation in 5 patients and non-cardiogenic pulmonary oedema in others. In conclusion it can be said that ECG should be carefully recorded and analysed in all patients of acute organophosphorus poisoning, and depending upon these changes and other clinical and biochemical parameters, the patients should immediately be shifted to well equipped ICU for better care which will reduce the mortality rate caused by these highly lethal poisons.

  2. Basic parameter estimation of binary neutron star systems by the advanced LIGO/Vigro network

    SciTech Connect

    Rodriguez, Carl L.; Farr, Benjamin; Raymond, Vivien; Farr, Will M.; Littenberg, Tyson B.; Fazi, Diego; Kalogera, Vicky

    2014-04-01

    Within the next five years, it is expected that the Advanced LIGO/Virgo network will have reached a sensitivity sufficient to enable the routine detection of gravitational waves. Beyond the initial detection, the scientific promise of these instruments relies on the effectiveness of our physical parameter estimation capabilities. A major part of this effort has been toward the detection and characterization of gravitational waves from compact binary coalescence, e.g., the coalescence of binary neutron stars. While several previous studies have investigated the accuracy of parameter estimation with advanced detectors, the majority have relied on approximation techniques such as the Fisher Matrix which are insensitive to the non-Gaussian nature of the gravitational wave posterior distribution function. Here we report average statistical uncertainties that will be achievable for strong detection candidates (S/N = 20) over a comprehensive sample of source parameters. We use the Markov Chain Monte Carlo based parameter estimation software developed by the LIGO/Virgo Collaboration with the goal of updating the previously quoted Fisher Matrix bounds. We find the recovery of the individual masses to be fractionally within 9% (15%) at the 68% (95%) credible intervals for equal-mass systems, and within 1.9% (3.7%) for unequal-mass systems. We also find that the Advanced LIGO/Virgo network will constrain the locations of binary neutron star mergers to a median uncertainty of 5.1 deg{sup 2} (13.5 deg{sup 2}) on the sky. This region is improved to 2.3 deg{sup 2} (6 deg{sup 2}) with the addition of the proposed LIGO India detector to the network. We also report the average uncertainties on the luminosity distances and orbital inclinations of strong detections that can be achieved by different network configurations.

  3. [A wireless ECG monitor based on ARM].

    PubMed

    Fan, Ai-Hua; Bian, Chun-Hua; Ning, Xin-Bao; He, Ai-Jun; Zhuang, Jian-Jun; Wu, Xu-Hui

    2008-11-01

    This paper presents a novel monitor which uses ARM controller AT91SAM7S64 as its main processor, LCM (Liquid Crystal Display Module) for displaying ECG waves, SD (Secure Digital memory) card for data storage and RF module PTR8000 for radio data transmission. This portable monitor boasts alarm function for abnormality and can provide dynamic ECG monitoring for patients.

  4. III Lead ECG Pulse Measurement Sensor

    NASA Astrophysics Data System (ADS)

    Thangaraju, S. K.; Munisamy, K.

    2015-09-01

    Heart rate sensing is very important. Method of measuring heart pulse by using an electrocardiogram (ECG) technique is described. Electrocardiogram is a measurement of the potential difference (the electrical pulse) generated by a cardiac tissue, mainly the heart. This paper also reports the development of a three lead ECG hardware system that would be the basis of developing a more cost efficient, portable and easy to use ECG machine. Einthoven's Three Lead method [1] is used for ECG signal extraction. Using amplifiers such as the instrumentation amplifier AD620BN and the conventional operational amplifier Ua741 that would be used to amplify the ECG signal extracted develop this system. The signal would then be filtered from noise using Butterworth filter techniques to obtain optimum output. Also a right leg guard was implemented as a safety feature to this system. Simulation was carried out for development of the system using P-spice Program.

  5. ECG signal denoising via empirical wavelet transform.

    PubMed

    Singh, Omkar; Sunkaria, Ramesh Kumar

    2016-12-29

    This paper presents new methods for baseline wander correction and powerline interference reduction in electrocardiogram (ECG) signals using empirical wavelet transform (EWT). During data acquisition of ECG signal, various noise sources such as powerline interference, baseline wander and muscle artifacts contaminate the information bearing ECG signal. For better analysis and interpretation, the ECG signal must be free of noise. In the present work, a new approach is used to filter baseline wander and power line interference from the ECG signal. The technique utilized is the empirical wavelet transform, which is a new method used to compute the building modes of a given signal. Its performance as a filter is compared to the standard linear filters and empirical mode decomposition.The results show that EWT delivers a better performance.

  6. Parameter on chronic periodontitis with advanced loss of periodontal support. American Academy of Periodontology.

    PubMed

    2000-05-01

    The American Academy of Periodontology has developed the following parameter on the treatment of chronic periodontitis with advanced loss of periodontal supporting tissues. Patients should be informed of the disease process, therapeutic alternatives, potential complications, expected results, and their responsibility in treatment. Consequences of no treatment should be explained. Failure to appropriately treat chronic periodontitis can result in progressive loss of periodontal supporting tissues, an adverse change in prognosis, and could result in tooth loss. Given this information, patients should then be able to make informed decisions regarding their periodontal therapy.

  7. ECG Based Heart Arrhythmia Detection Using Wavelet Coherence and Bat Algorithm

    NASA Astrophysics Data System (ADS)

    Kora, Padmavathi; Sri Rama Krishna, K.

    2016-12-01

    Atrial fibrillation (AF) is a type of heart abnormality, during the AF electrical discharges in the atrium are rapid, results in abnormal heart beat. The morphology of ECG changes due to the abnormalities in the heart. This paper consists of three major steps for the detection of heart diseases: signal pre-processing, feature extraction and classification. Feature extraction is the key process in detecting the heart abnormality. Most of the ECG detection systems depend on the time domain features for cardiac signal classification. In this paper we proposed a wavelet coherence (WTC) technique for ECG signal analysis. The WTC calculates the similarity between two waveforms in frequency domain. Parameters extracted from WTC function is used as the features of the ECG signal. These features are optimized using Bat algorithm. The Levenberg Marquardt neural network classifier is used to classify the optimized features. The performance of the classifier can be improved with the optimized features.

  8. Improving ECG Services at a Children's Hospital: Implementation of a Digital ECG System

    PubMed Central

    Osei, Frank A.; Gates, Gregory J.; Choi, Steven J.; Hsu, Daphne T.; Pass, Robert H.; Ceresnak, Scott R.

    2015-01-01

    Background. The use of digital ECG software and services is becoming common. We hypothesized that the introduction of a completely digital ECG system would increase the volume of ECGs interpreted at our children's hospital. Methods. As part of a hospital wide quality improvement initiative, a digital ECG service (MUSE, GE) was implemented at the Children's Hospital at Montefiore in June 2012. The total volume of ECGs performed in the first 6 months of the digital ECG era was compared to 18 months of the predigital era. Predigital and postdigital data were compared via t-tests. Results. The mean ECGs interpreted per month were 53 ± 16 in the predigital era and 216 ± 37 in the postdigital era (p < 0.001), a fourfold increase in ECG volume after introduction of the digital system. There was no significant change in inpatient or outpatient service volume during that time. The mean billing time decreased from 21 ± 27 days in the postdigital era to 12 ± 5 days in the postdigital era (p < 0.001). Conclusion. Implementation of a digital ECG system increased the volume of ECGs officially interpreted and reported. PMID:26451150

  9. An ECG analysis interactive training system for understanding arrhythmias.

    PubMed

    Lessard, Yvon; Sinteff, Jean-Paul; Siregar, Pridi; Julen, Nathalie; Hannouche, Frédéric; Rio, Stéphane; Le Beux, Pierre

    2009-01-01

    The ECG remains a daily diagnostic tool for the detection of numerous cardiovascular diseases. Our goal was to use a computerized qualitative model (QM) of heart in order to build cases of simple arrhythmias dedicated to initial and more advanced medical teaching. The original QM is able to generate videograms of many cardiac disturbances. A Flash player is used to view ECG, synchronous Lewis diagram and chromatic 2D cardiac animation of a specific case. OAAT is a standardized 18 yes/no answers questionnaire which allows the learner to diagnose five main types of arrhythmias that can be compared with normal sinus rhythm (NSR) analysis. This new tool has been recently used by medical students during practical sessions. Based on medical reasoning learning on NSR video and upon trying to recognize an abnormal cardiac rhythm, all users can reach the 100% winning score since they can perform as many attempts as they like. We believe that unlimited case review with questionnaire answering, ECG and Lewis diagram replay and step-by-step visualization of the abnormal propagation of the cardiac impulse on the 2D heart videos are a highly efficient means to help students understand even complex arrhythmic mechanisms.

  10. A configurable and low-power mixed signal SoC for portable ECG monitoring applications.

    PubMed

    Kim, Hyejung; Kim, Sunyoung; Van Helleputte, Nick; Artes, Antonio; Konijnenburg, Mario; Huisken, Jos; Van Hoof, Chris; Yazicioglu, Refet Firat

    2014-04-01

    This paper describes a mixed-signal ECG System-on-Chip (SoC) that is capable of implementing configurable functionality with low-power consumption for portable ECG monitoring applications. A low-voltage and high performance analog front-end extracts 3-channel ECG signals and single channel electrode-tissue-impedance (ETI) measurement with high signal quality. This can be used to evaluate the quality of the ECG measurement and to filter motion artifacts. A custom digital signal processor consisting of 4-way SIMD processor provides the configurability and advanced functionality like motion artifact removal and R peak detection. A built-in 12-bit analog-to-digital converter (ADC) is capable of adaptive sampling achieving a compression ratio of up to 7, and loop buffer integration reduces the power consumption for on-chip memory access. The SoC is implemented in 0.18 μm CMOS process and consumes 32 μ W from a 1.2 V while heart beat detection application is running, and integrated in a wireless ECG monitoring system with Bluetooth protocol. Thanks to the ECG SoC, the overall system power consumption can be reduced significantly.

  11. An efficient unsupervised fetal QRS complex detection from abdominal maternal ECG.

    PubMed

    Varanini, M; Tartarisco, G; Billeci, L; Macerata, A; Pioggia, G; Balocchi, R

    2014-08-01

    Non-invasive fetal heart rate is of great relevance in clinical practice to monitor fetal health state during pregnancy. To date, however, despite significant advances in the field of electrocardiography, the analysis of abdominal fetal ECG is considered a challenging problem for biomedical and signal processing communities. This is mainly due to the low signal-to-noise ratio of fetal ECG and difficulties in cancellation of maternal QRS complexes, motion and electromyographic artefacts. In this paper we present an efficient unsupervised algorithm for fetal QRS complex detection from abdominal multichannel signal recordings combining ICA and maternal ECG cancelling, which outperforms each single method. The signal is first pre-processed to remove impulsive artefacts, baseline wandering and power line interference. The following steps are then applied: maternal ECG extraction through independent component analysis (ICA); maternal QRS detection; maternal ECG cancelling through weighted singular value decomposition; enhancing of fetal ECG through ICA and fetal QRS detection. We participated in the Physionet/Computing in Cardiology Challenge 2013, obtaining the top official scores of the challenge (among 53 teams of participants) of event 1 and event 2 concerning fetal heart rate and fetal interbeat intervals estimation section. The developed algorithms are released as open-source on the Physionet website.

  12. THE ADVANCED CAMERA FOR SURVEYS GENERAL CATALOG: STRUCTURAL PARAMETERS FOR APPROXIMATELY HALF A MILLION GALAXIES

    SciTech Connect

    Griffith, Roger L.; Kirkpatrick, J. Davy; Cooper, Michael C.; Newman, Jeffrey A.; Moustakas, Leonidas A.; Stern, Daniel; Comerford, Julia M.; Davis, Marc; Lotz, Jennifer M.; Koekemoer, Anton M.; Barden, Marco; Conselice, Christopher J.; Capak, Peter L.; Scoville, Nick; Sheth, Kartik; Shopbell, Patrick; Faber, S. M.; Koo, David C.; Willmer, Christopher N. A.; and others

    2012-05-01

    We present the Advanced Camera for Surveys General Catalog (ACS-GC), a photometric and morphological database using publicly available data obtained with the Advanced Camera for Surveys (ACS) instrument on the Hubble Space Telescope. The goal of the ACS-GC database is to provide a large statistical sample of galaxies with reliable structural and distance measurements to probe the evolution of galaxies over a wide range of look-back times. The ACS-GC includes approximately 470,000 astronomical sources (stars + galaxies) derived from the AEGIS, COSMOS, GEMS, and GOODS surveys. GALAPAGOS was used to construct photometric (SEXTRACTOR) and morphological (GALFIT) catalogs. The analysis assumes a single Sersic model for each object to derive quantitative structural parameters. We include publicly available redshifts from the DEEP2, COMBO-17, TKRS, PEARS, ACES, CFHTLS, and zCOSMOS surveys to supply redshifts (spectroscopic and photometric) for a considerable fraction ({approx}74%) of the imaging sample. The ACS-GC includes color postage stamps, GALFIT residual images, and photometry, structural parameters, and redshifts combined into a single catalog.

  13. [A USB-Based Digital ECG Sensor].

    PubMed

    Shi Bol; Kong, Xiangyong; Ma, Xiaozhi; Zhang, Genxuan

    2016-01-01

    Based on the ECG-specific BMD 101 integrated circun chip, this study designed a digital ECG sensor. In practical application, users just need to connect the ECG sensor 'o upper computer (such as PC or mobile phone) through USB interface, to realize the functions including display, alarm, saving, transfer etc. After tests, They demonstrate that the sensor can be applied to the detection of arrhythmia, such as bigeminy coupled rhythm, proiosystole etc. Besides, the sensor has various advantages in monitoring an managing the heart health of people out of hospital, including low cost, small volume, usableness, simplicity of operation etc.

  14. Arrhythmia recognition and classification using combined linear and nonlinear features of ECG signals.

    PubMed

    Elhaj, Fatin A; Salim, Naomie; Harris, Arief R; Swee, Tan Tian; Ahmed, Taqwa

    2016-04-01

    Arrhythmia is a cardiac condition caused by abnormal electrical activity of the heart, and an electrocardiogram (ECG) is the non-invasive method used to detect arrhythmias or heart abnormalities. Due to the presence of noise, the non-stationary nature of the ECG signal (i.e. the changing morphology of the ECG signal with respect to time) and the irregularity of the heartbeat, physicians face difficulties in the diagnosis of arrhythmias. The computer-aided analysis of ECG results assists physicians to detect cardiovascular diseases. The development of many existing arrhythmia systems has depended on the findings from linear experiments on ECG data which achieve high performance on noise-free data. However, nonlinear experiments characterize the ECG signal more effectively sense, extract hidden information in the ECG signal, and achieve good performance under noisy conditions. This paper investigates the representation ability of linear and nonlinear features and proposes a combination of such features in order to improve the classification of ECG data. In this study, five types of beat classes of arrhythmia as recommended by the Association for Advancement of Medical Instrumentation are analyzed: non-ectopic beats (N), supra-ventricular ectopic beats (S), ventricular ectopic beats (V), fusion beats (F) and unclassifiable and paced beats (U). The characterization ability of nonlinear features such as high order statistics and cumulants and nonlinear feature reduction methods such as independent component analysis are combined with linear features, namely, the principal component analysis of discrete wavelet transform coefficients. The features are tested for their ability to differentiate different classes of data using different classifiers, namely, the support vector machine and neural network methods with tenfold cross-validation. Our proposed method is able to classify the N, S, V, F and U arrhythmia classes with high accuracy (98.91%) using a combined support

  15. Advanced system identification techniques for wind turbine structures with special emphasis on modal parameters

    NASA Astrophysics Data System (ADS)

    Bialasiewicz, J. T.

    1995-06-01

    The goal is to develop advanced system identification techniques that can be used to accurately measure the frequency response functions of a wind-turbine structure immersed in wind noise. To allow for accurate identification, the authors have developed a special test signal called the pseudo-random binary sequence (PRBS). The Matlab program that generates this signal allows the user to interactively tailor its parameters for the frequency range of interest based on the response of the wind turbine under test. By controlling NREL's Mobile Hydraulic Shaker System, which is attached to the wind turbine structure, the PRBS signal produces the wide-band excitation necessary to perform system identification in the presence of wind noise. The techniques presented here will enable researchers to obtain modal parameters from an operating wind turbine, including frequencies, damping coefficients, and mode shapes. More importantly, the algorithms they have developed and tested (so far using input-output data from a simulated structure) permit state-space representation of the system under test, particularly the modal state space representation. This is the only system description that reveals the internal behavior of the system, such as the interaction between the physical parameters, and which, in contrast to transfer functions, is valid for non-zero initial conditions.

  16. Wavelets for full reconfigurable ECG acquisition system

    NASA Astrophysics Data System (ADS)

    Morales, D. P.; García, A.; Castillo, E.; Meyer-Baese, U.; Palma, A. J.

    2011-06-01

    This paper presents the use of wavelet cores for a full reconfigurable electrocardiogram signal (ECG) acquisition system. The system is compound by two reconfigurable devices, a FPGA and a FPAA. The FPAA is in charge of the ECG signal acquisition, since this device is a versatile and reconfigurable analog front-end for biosignals. The FPGA is in charge of FPAA configuration, digital signal processing and information extraction such as heart beat rate and others. Wavelet analysis has become a powerful tool for ECG signal processing since it perfectly fits ECG signal shape. The use of these cores has been integrated in the LabVIEW FPGA module development tool that makes possible to employ VHDL cores within the usual LabVIEW graphical programming environment, thus freeing the designer from tedious and time consuming design of communication interfaces. This enables rapid test and graphical representation of results.

  17. CNT/PDMS composite flexible dry electrodes for long-term ECG monitoring.

    PubMed

    Jung, Ha-Chul; Moon, Jin-Hee; Baek, Dong-Hyun; Lee, Jae-Hee; Choi, Yoon-Young; Hong, Joung-Sook; Lee, Sang-Hoon

    2012-05-01

    We fabricated a carbon nanotube (CNT)/ polydimethylsiloxane (PDMS) composite-based dry ECG electrode that can be readily connected to conventional ECG devices, and showed its long-term wearable monitoring capability and robustness to motion and sweat. While the dispersion of CNTs in PDMS is challenging, we optimized the process to disperse untreated CNTs within PDMS by mechanical force only. The electrical and mechanical characteristics of the CNT/PDMS electrode were tested according to the concentration of CNTs and its thickness. The performances of ECG electrodes were evaluated by using 36 types of electrodes which were fabricated with different concentrations of CNTs, and with a differing diameter and thickness. The ECG signals were obtained by using electrodes of diverse sizes to observe the effects of motion and sweat, and the proposed electrode was shown to be robust to both factors. The CNT concentration and diameter of the electrodes were critical parameters in obtaining high-quality ECG signals. The electrode was shown to be biocompatible from the cytotoxicity test. A seven-day continuous wearability test showed that the quality of the ECG signal did not degrade over time, and skin reactions such as itching or erythema were not observed. This electrode could be used for the long-term measurement of other electrical biosignals for ubiquitous health monitoring including EMG, EEG, and ERG.

  18. Smartphone home monitoring of ECG

    NASA Astrophysics Data System (ADS)

    Szu, Harold; Hsu, Charles; Moon, Gyu; Landa, Joseph; Nakajima, Hiroshi; Hata, Yutaka

    2012-06-01

    A system of ambulatory, halter, electrocardiography (ECG) monitoring system has already been commercially available for recording and transmitting heartbeats data by the Internet. However, it enjoys the confidence with a reservation and thus a limited market penetration, our system was targeting at aging global villagers having an increasingly biomedical wellness (BMW) homecare needs, not hospital related BMI (biomedical illness). It was designed within SWaP-C (Size, Weight, and Power, Cost) using 3 innovative modules: (i) Smart Electrode (lowpower mixed signal embedded with modern compressive sensing and nanotechnology to improve the electrodes' contact impedance); (ii) Learnable Database (in terms of adaptive wavelets transform QRST feature extraction, Sequential Query Relational database allowing home care monitoring retrievable Aided Target Recognition); (iii) Smartphone (touch screen interface, powerful computation capability, caretaker reporting with GPI, ID, and patient panic button for programmable emergence procedure). It can provide a supplementary home screening system for the post or the pre-diagnosis care at home with a build-in database searchable with the time, the place, and the degree of urgency happened, using in-situ screening.

  19. The Cardiac Safety Research Consortium ECG database.

    PubMed

    Kligfield, Paul; Green, Cynthia L

    2012-01-01

    The Cardiac Safety Research Consortium (CSRC) ECG database was initiated to foster research using anonymized, XML-formatted, digitized ECGs with corresponding descriptive variables from placebo- and positive-control arms of thorough QT studies submitted to the US Food and Drug Administration (FDA) by pharmaceutical sponsors. The database can be expanded to other data that are submitted directly to CSRC from other sources, and currently includes digitized ECGs from patients with genotyped varieties of congenital long-QT syndrome; this congenital long-QT database is also linked to ambulatory electrocardiograms stored in the Telemetric and Holter ECG Warehouse (THEW). Thorough QT data sets are available from CSRC for unblinded development of algorithms for analysis of repolarization and for blinded comparative testing of algorithms developed for the identification of moxifloxacin, as used as a positive control in thorough QT studies. Policies and procedures for access to these data sets are available from CSRC, which has developed tools for statistical analysis of blinded new algorithm performance. A recently approved CSRC project will create a data set for blinded analysis of automated ECG interval measurements, whose initial focus will include comparison of four of the major manufacturers of automated electrocardiographs in the United States. CSRC welcomes application for use of the ECG database for clinical investigation.

  20. [Study on mobile phone based wireless ECG monitoring technology system realization and performance test].

    PubMed

    Yu, Yang; Liu, Jing

    2010-11-01

    This paper introduces a novel mobile phone based wireless real-time ECG monitoring system. And experiments were conducted to demonstrate the reliability and stability of the device. This novel system not only addresses the contradiction between continuous monitoring and device cost, but also represents advanced concepts of low cost medicine and personal health management.

  1. Quality assessment of digital annotated ECG data from clinical trials by the FDA ECG Warehouse.

    PubMed

    Sarapa, Nenad

    2007-09-01

    The FDA mandates that digital electrocardiograms (ECGs) from 'thorough' QTc trials be submitted into the ECG Warehouse in Health Level 7 extended markup language format with annotated onset and offset points of waveforms. The FDA did not disclose the exact Warehouse metrics and minimal acceptable quality standards. The author describes the Warehouse scoring algorithms and metrics used by FDA, points out ways to improve FDA review and suggests Warehouse benefits for pharmaceutical sponsors. The Warehouse ranks individual ECGs according to their score for each quality metric and produces histogram distributions with Warehouse-specific thresholds that identify ECGs of questionable quality. Automatic Warehouse algorithms assess the quality of QT annotation and duration of manual QT measurement by the central ECG laboratory.

  2. The chaos and order in human ECG under the influence of the external perturbations

    NASA Astrophysics Data System (ADS)

    Ragulskaya, Maria; Valeriy, Pipin

    The results of the many-year telecommunication heliomedical monitoring "Heliomed" show, that space weather and geophysical factor variations serve as a training factor for the adaptation-resistant member of the human population. Here we discuss the specific properties of the human ECG discovered in our experiment. The program "Heliomed" is carried out simultaneously at the different geographical areas that cover the different latitudes. The daily registered param-eters include: the psycho-emotional tests and the 1-st lead ECG, the arterial pressure, the variability cardiac contraction, the electric conduction of bioactive points on skin. The results time series compared with daily values of space weather and geomagnetic parameters. The analysis of ECG signal proceeds as follows. At first step we construct the ECG embedding into 3D phase space using the first 3 Principal Components of the ECG time series. Next, we divide ECG on the separate cycles using the maxima of the ECG's QRS complex. Then, we filter out the non-typical ECG beats by means of the Housdorff distance. Finally, we average the example of the ECG time series along the reference trajectory and study of the dynamical characteristics of the averaged ECG beat. It is found, that the ECG signal embeded in 3D phase space can be considered as a mix of a few states. At the rest, the occurrence of the primary ECG state compare to additional ones is about 8:2. The occurrence of the primary state increases after the stress. The main effect of the external perturbation is observed in structural change of the cardio-cycle and not in the variability of the R-R interval. The num-ber of none-typical cycles increase during an isolated magnetic storm. At the all monitoring centers participating experiment the same type of changes in the cardiac activity parameters is detected to go nearly simultaneously during an isolated magnetic storm. To understand the origin of the standard cardio-cycle changes we use the dynamical

  3. Mass exponent spectrum analysis of human ECG signals and its application to complexity detection

    NASA Astrophysics Data System (ADS)

    Yang, Xiaodong; Du, Sidan; Ning, Xinbao; Bian, Chunhua

    2008-06-01

    The complexity of electrocardiogram (ECG) signal may reflect the physiological function and healthy status of the heart. In this paper, we introduced two novel intermediate parameters of multifractality, the mass exponent spectrum curvature and area, to characterize the nonlinear complexity of ECG signal. These indicators express the nonlinear superposition of the discrepancies of singularity strengths from all the adjacent points of the spectrum curve and thus overall subsets of original fractal structure. The evaluation of binomial multifractal sets validated these two variables were entirely effective in exploring the complexity of this time series. We then studied the ECG mass exponent spectra taken from the cohorts of healthy, ischemia and myocardial infarction (MI) sufferer based on a large sets of 12 leads’ recordings, and took the statistical averages among each crowd. Experimental results suggest the two values from healthy ECG are apparently larger than those from the heart diseased. While the values from ECG of MI sufferer are much smaller than those from the other two groups. As for the ischemia sufferer, they are almost of moderate magnitude. Afterward, we compared these new indicators with the nonlinear parameters of singularity spectrum. The classification indexes and results of total separating ratios (TSR, defined in the paper) both indicated that our method could achieve a better effect. These conclusions may be of some values in early diagnoses and clinical applications.

  4. Parameter Estimation for Binary Neutron-star Coalescences with Realistic Noise during the Advanced LIGO Era

    NASA Astrophysics Data System (ADS)

    Berry, Christopher P. L.; Mandel, Ilya; Middleton, Hannah; Singer, Leo P.; Urban, Alex L.; Vecchio, Alberto; Vitale, Salvatore; Cannon, Kipp; Farr, Ben; Farr, Will M.; Graff, Philip B.; Hanna, Chad; Haster, Carl-Johan; Mohapatra, Satya; Pankow, Chris; Price, Larry R.; Sidery, Trevor; Veitch, John

    2015-05-01

    Advanced ground-based gravitational-wave (GW) detectors begin operation imminently. Their intended goal is not only to make the first direct detection of GWs, but also to make inferences about the source systems. Binary neutron-star mergers are among the most promising sources. We investigate the performance of the parameter-estimation (PE) pipeline that will be used during the first observing run of the Advanced Laser Interferometer Gravitational-wave Observatory (aLIGO) in 2015: we concentrate on the ability to reconstruct the source location on the sky, but also consider the ability to measure masses and the distance. Accurate, rapid sky localization is necessary to alert electromagnetic (EM) observatories so that they can perform follow-up searches for counterpart transient events. We consider PE accuracy in the presence of non-stationary, non-Gaussian noise. We find that the character of the noise makes negligible difference to the PE performance at a given signal-to-noise ratio. The source luminosity distance can only be poorly constrained, since the median 90% (50%) credible interval scaled with respect to the true distance is 0.85 (0.38). However, the chirp mass is well measured. Our chirp-mass estimates are subject to systematic error because we used gravitational-waveform templates without component spin to carry out inference on signals with moderate spins, but the total error is typically less than {{10}-3} {{M}⊙ }. The median 90% (50%) credible region for sky localization is ˜ 600 {{deg }2} (˜ 150 {{deg }2}), with 3% (30%) of detected events localized within 100 {{deg }2}. Early aLIGO, with only two detectors, will have a sky-localization accuracy for binary neutron stars of hundreds of square degrees; this makes EM follow-up challenging, but not impossible.

  5. Intraoperative MRI electrical noise and monitor ECG filters affect arrhythmia detection and identification.

    PubMed

    Bailey, Melissa; Kirchen, Gwynne; Bonaventura, Bridget; Rosborough, Kelly; Abdel-Rasoul, Mahmoud; Dzwonczyk, Roger

    2012-06-01

    anesthetist must be able to effectively monitor a patient in the presence of iMRI-generated EN. Depending on the OR design, the patient may be out of the anesthetist's direct view during a scan procedure. The anesthetist must rely on monitored physiologic parameters to assess patient status during this time. He/she should be familiar with his/her monitor's filtering capabilities and routinely adjust the ECG filters to achieve the best compromise between minimized EN effects and maximized displayed ECG signal quality.

  6. Advances in three-dimensional field analysis and evaluation of performance parameters of electrical machines

    NASA Astrophysics Data System (ADS)

    Sivasubramaniam, Kiruba

    This thesis makes advances in three dimensional finite element analysis of electrical machines and the quantification of their parameters and performance. The principal objectives of the thesis are: (1)the development of a stable and accurate method of nonlinear three-dimensional field computation and application to electrical machinery and devices; and (2)improvement in the accuracy of determination of performance parameters, particularly forces and torque computed from finite elements. Contributions are made in two general areas: a more efficient formulation for three dimensional finite element analysis which saves time and improves accuracy, and new post-processing techniques to calculate flux density values from a given finite element solution. A novel three-dimensional magnetostatic solution based on a modified scalar potential method is implemented. This method has significant advantages over the traditional total scalar, reduced scalar or vector potential methods. The new method is applied to a 3D geometry of an iron core inductor and a permanent magnet motor. The results obtained are compared with those obtained from traditional methods, in terms of accuracy and speed of computation. A technique which has been observed to improve force computation in two dimensional analysis using a local solution of Laplace's equation in the airgap of machines is investigated and a similar method is implemented in the three dimensional analysis of electromagnetic devices. A new integral formulation to improve force calculation from a smoother flux-density profile is also explored and implemented. Comparisons are made and conclusions drawn as to how much improvement is obtained and at what cost. This thesis also demonstrates the use of finite element analysis to analyze torque ripples due to rotor eccentricity in permanent magnet BLDC motors. A new method for analyzing torque harmonics based on data obtained from a time stepping finite element analysis of the machine is

  7. Robust human identification using ecg: eigenpulse revisited

    NASA Astrophysics Data System (ADS)

    Jang, Daniel; Wendelken, Suzanne; Irvine, John M.

    2010-04-01

    Biometrics, such as fingerprint, iris scan, and face recognition, offer methods for identifying individuals based on a unique physiological measurement. Recent studies indicate that a person's electrocardiogram (ECG) may also provide a unique biometric signature. Several methods for processing ECG data have appeared in the literature and most approaches rest on an initial detection and segmentation of the heartbeats. Various sources of noise, such as sensor noise, poor sensor placement, or muscle movements, can degrade the ECG signal and introduce errors into the heartbeat segmentation. This paper presents a screening technique for assessing the quality of each segmented heartbeat. Using this technique, a higher quality signal can be extracted to support the identification task. We demonstrate the benefits of this quality screening using a principal component technique known as eigenpulse. The analysis demonstrated the improvement in performance attributable to the quality screening.

  8. Recent Advances on Multi-Parameter Flow Cytometry to Characterize Antimicrobial Treatments

    PubMed Central

    Léonard, Lucie; Bouarab Chibane, Lynda; Ouled Bouhedda, Balkis; Degraeve, Pascal; Oulahal, Nadia

    2016-01-01

    The investigation on antimicrobial mechanisms is a challenging and crucial issue in the fields of food or clinical microbiology, as it constitutes a prerequisite to the development of new antimicrobial processes or compounds, as well as to anticipate phenomenon of microbial resistance. Nowadays it is accepted that a cells population exposed to a stress can cause the appearance of different cell populations and in particular sub-lethally compromised cells which could be defined as viable but non-culturable (VBNC). Recent advances on flow cytometry (FCM) and especially on multi-parameter flow cytometry (MP-FCM) provide the opportunity to obtain high-speed information at real time on damage at single-cell level. This review gathers MP-FCM methodologies based on individual and simultaneous staining of microbial cells employed to investigate their physiological state following different physical and chemical antimicrobial treatments. Special attention will be paid to recent studies exploiting the possibility to corroborate MP-FCM results with additional techniques (plate counting, microscopy, spectroscopy, molecular biology techniques, membrane modeling) in order to elucidate the antimicrobial mechanism of action of a given antimicrobial treatment or compound. The combination of MP-FCM methodologies with these additional methods is namely a promising and increasingly used approach to give further insight in differences in microbial sub-population evolutions in response to antimicrobial treatments. PMID:27551279

  9. Developing a DICOM Middleware to Implement ECG Conversion and Viewing.

    PubMed

    Ling-Ling, Wang; Ni-Ni, Rao; Li-Xin, Pu; Gang, Wang

    2005-01-01

    Nowadays, medical environment is integrated and complicated, involving large amounts of various medical data, such as images, waveforms and other digital data. For the interoperability of images and waveforms in imaging context, the images and waveforms usually need to be interchanged and stored using one standard. DICOM is the best choice, which is an international standard for the communication and storage of medical information. In this paper, we developed a DICOM middleware with capability of converting SCP-ECG, the European standard for resting ECGs, into DICOM ECGs. Then an ECG viewing component is implemented, which can parse and display SCP-ECG records and DICOM ECGs. The research results show that our work can realize seamless workflows in multi-vendor environment, contribute to the harmonization of ECG standards, and facilitate digital ECG applications.

  10. [Implementation of ECG Monitoring System Based on Internet of Things].

    PubMed

    Lu, Liangliang; Chen, Minya

    2015-11-01

    In order to expand the capabilities of hospital's traditional ECG device and enhance medical staff's work efficiency, an ECG monitoring system based on internet of things is introduced. The system can monitor ECG signals in real time and analyze data using ECG sensor, PDA, Web servers, which embeds C language, Android systems, .NET, wireless network and other technologies. After experiments, it can be showed that the system has high reliability and stability and can bring the convenience to medical staffs.

  11. Simplified 2D Bidomain Model of Whole Heart Electrical Activity and ECG Generation

    NASA Astrophysics Data System (ADS)

    Sovilj, Siniša; Magjarević, Ratko; Abed, Amr Al; Lovell, Nigel H.; Dokos, Socrates

    2014-06-01

    The aim of this study was the development of a geometrically simple and highly computationally-efficient two dimensional (2D) biophysical model of whole heart electrical activity, incorporating spontaneous activation of the sinoatrial node (SAN), the specialized conduction system, and realistic surface ECG morphology computed on the torso. The FitzHugh-Nagumo (FHN) equations were incorporated into a bidomain finite element model of cardiac electrical activity, which was comprised of a simplified geometry of the whole heart with the blood cavities, the lungs and the torso as an extracellular volume conductor. To model the ECG, we placed four electrodes on the surface of the torso to simulate three Einthoven leads VI, VII and VIII from the standard 12-lead system. The 2D model was able to reconstruct ECG morphology on the torso from action potentials generated at various regions of the heart, including the sinoatrial node, atria, atrioventricular node, His bundle, bundle branches, Purkinje fibers, and ventricles. Our 2D cardiac model offers a good compromise between computational load and model complexity, and can be used as a first step towards three dimensional (3D) ECG models with more complex, precise and accurate geometry of anatomical structures, to investigate the effect of various cardiac electrophysiological parameters on ECG morphology.

  12. Designing for reliable textile neonatal ECG monitoring using multi-sensor recordings.

    PubMed

    Bouwstra, S; Chen, W; Oetomo, S Bambang; Feijs, L M G; Cluitmans, P J M

    2011-01-01

    When designing an ECG monitoring system embedded with textile electrodes for comfort, it is challenging to ensure reliable monitoring, because textile electrodes suffer from motion artifacts and incidental poor signal quality. For the design of a comfortable monitoring system for prematurely born babies in the Neonatal Intensive Care Unit (NICU), we propose the concepts of 'diversity measurement' and 'context awareness' to improve reliability. Clinical multi-modal sensor data was collected in the NICU with the Smart Jacket connected to a state-of-the-art amplifier. We found that the ECG signals quality varied among sensors and varied over time, and found correlations between ECG signal, acceleration data, and context, which supports the feasibility of the concepts. Our explorative system level approach has lead to design parameters and meta-insights into the role of clinical validation in the design process.

  13. 21 CFR 892.1970 - Radiographic ECG/respirator synchronizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic ECG/respirator synchronizer. 892.1970... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1970 Radiographic ECG/respirator synchronizer. (a) Identification. A radiographic ECG/respirator synchronizer is a device intended to be used...

  14. [Research of DICOM-ECG implementation based on DCMTK].

    PubMed

    Wang, Xiang; Wu, Jian; Ma, Yaquanz; Peng, Cheng

    2013-11-01

    Parsed the ECG descriptions in DICOM 3.0 standard and accomplished a DICOM-ECG file which conforms to the DICOM standard by a toolkit DCMTK. The DICOM-ECG file can communicate with systems which support DICOM standard directly.

  15. Multichannel ECG and Noise Modeling: Application to Maternal and Fetal ECG Signals

    NASA Astrophysics Data System (ADS)

    Sameni, Reza; Clifford, Gari D.; Jutten, Christian; Shamsollahi, Mohammad B.

    2007-12-01

    A three-dimensional dynamic model of the electrical activity of the heart is presented. The model is based on the single dipole model of the heart and is later related to the body surface potentials through a linear model which accounts for the temporal movements and rotations of the cardiac dipole, together with a realistic ECG noise model. The proposed model is also generalized to maternal and fetal ECG mixtures recorded from the abdomen of pregnant women in single and multiple pregnancies. The applicability of the model for the evaluation of signal processing algorithms is illustrated using independent component analysis. Considering the difficulties and limitations of recording long-term ECG data, especially from pregnant women, the model described in this paper may serve as an effective means of simulation and analysis of a wide range of ECGs, including adults and fetuses.

  16. ECG denoising and fiducial point extraction using an extended Kalman filtering framework with linear and nonlinear phase observations.

    PubMed

    Akhbari, Mahsa; Shamsollahi, Mohammad B; Jutten, Christian; Armoundas, Antonis A; Sayadi, Omid

    2016-02-01

    In this paper we propose an efficient method for denoising and extracting fiducial point (FP) of ECG signals. The method is based on a nonlinear dynamic model which uses Gaussian functions to model ECG waveforms. For estimating the model parameters, we use an extended Kalman filter (EKF). In this framework called EKF25, all the parameters of Gaussian functions as well as the ECG waveforms (P-wave, QRS complex and T-wave) in the ECG dynamical model, are considered as state variables. In this paper, the dynamic time warping method is used to estimate the nonlinear ECG phase observation. We compare this new approach with linear phase observation models. Using linear and nonlinear EKF25 for ECG denoising and nonlinear EKF25 for fiducial point extraction and ECG interval analysis are the main contributions of this paper. Performance comparison with other EKF-based techniques shows that the proposed method results in higher output SNR with an average SNR improvement of 12 dB for an input SNR of -8 dB. To evaluate the FP extraction performance, we compare the proposed method with a method based on partially collapsed Gibbs sampler and an established EKF-based method. The mean absolute error and the root mean square error of all FPs, across all databases are 14 ms and 22 ms, respectively, for our proposed method, with an advantage when using a nonlinear phase observation. These errors are significantly smaller than errors obtained with other methods. For ECG interval analysis, with an absolute mean error and a root mean square error of about 22 ms and 29 ms, the proposed method achieves better accuracy and smaller variability with respect to other methods.

  17. The Development of a Portable ECG Monitor Based on DSP

    NASA Astrophysics Data System (ADS)

    Nan, CHI Jian; Tao, YAN Yan; Meng Chen, LIU; Li, YANG

    With the advent of global information, researches of Smart Home system are in the ascendant, the ECG real-time detection, and wireless transmission of ECG become more useful. In order to achieve the purpose we developed a portable ECG monitor which achieves the purpose of cardiac disease remote monitoring, and will be used in the physical and psychological disease surveillance in smart home system, we developed this portable ECG Monitor, based on the analysis of existing ECG Monitor, using TMS320F2812 as the core controller, which complete the signal collection, storage, processing, waveform display and transmission.

  18. Sparse Matrix for ECG Identification with Two-Lead Features

    PubMed Central

    Tseng, Kuo-Kun; Luo, Jiao; Wang, Wenmin; Haiting, Dong

    2015-01-01

    Electrocardiograph (ECG) human identification has the potential to improve biometric security. However, improvements in ECG identification and feature extraction are required. Previous work has focused on single lead ECG signals. Our work proposes a new algorithm for human identification by mapping two-lead ECG signals onto a two-dimensional matrix then employing a sparse matrix method to process the matrix. And that is the first application of sparse matrix techniques for ECG identification. Moreover, the results of our experiments demonstrate the benefits of our approach over existing methods. PMID:25961074

  19. Hyperkalemia Induced Brugada Phenocopy: A Rare ECG Manifestation

    PubMed Central

    Akbar, Ghulam; Mirrani, Ghazi

    2017-01-01

    Brugada syndrome (BrS) is an inherited disorder of cardiac ion channels characterized by peculiar ECG findings predisposing individuals to ventricular arrhythmias, syncope, and sudden cardiac death (SCD). Various electrolyte disturbances and ion channels blocking drugs could also provoke BrS ECG findings without genetic BrS. Clinical differentiation and recognition are essential for guiding the legitimate action. Hyperkalemia is well known to cause a wide variety of ECG manifestations. Severe hyperkalemia can even cause life threatening ventricular arrhythmias and cardiac conduction abnormalities. Most common ECG findings include peaked tall T waves with short PR interval and wide QRS complex. Since it is very commonly encountered disorder, physicians need to be aware of even its rare ECG manifestations, which include ST segment elevation and Brugada pattern ECG (BrP). We are adding a case to the limited literature about hyperkalemia induced reversible Brugada pattern ECG changes. PMID:28326201

  20. Identifying UMLS concepts from ECG Impressions using KnowledgeMap.

    PubMed

    Denny, Joshua C; Spickard, Anderson; Miller, Randolph A; Schildcrout, Jonathan; Darbar, Dawood; Rosenbloom, S Trent; Peterson, Josh F

    2005-01-01

    Electrocardiogram (ECG) impressions represent a wealth of medical information for potential decision support and drug-effect discovery. Much of this information is inaccessible to automated methods in the free-text portion of the ECG report. We studied the application of the KnowledgeMap concept identifier (KMCI) to map Unified Medical Language System (UMLS) concepts from ECG impressions. ECGs were processed by KMCI and the results scored for accuracy by multiple raters. Reviewers also recorded unidentified concepts through the scoring interface. Overall, KMCI correctly identified 1059 out of 1171 concepts for a recall of 0.90. Precision, indicating the proportion of ECG concepts correctly identified, was 0.94. KMCI was particularly effective at identifying ECG rhythms (330/333), perfusion changes (65/66), and noncardiac medical concepts (11/11). In conclusion, KMCI is an effective method for mapping ECG impressions to UMLS concepts.

  1. An awareness approach to analyze ECG streaming data.

    PubMed

    Don, S; Chung, Duckwon; Choi, Eunmi; Min, Dugki

    2013-04-01

    Real-time remote health monitoring systems are experiencing tremendous advancement resulting from improvements in low power, reliable sensors; yet they are still constrained to low-level interpretation. Automatic data analysis continues to be a tedious task due to a lack of efficient, reliable platforms for data analysis. In this paper, we present a system for monitoring patients remotely by emphasizing the strength of Complex Event Processing (CEP) and Situation Awareness. In this approach, the system makes decisions in a declarative way, which helps medical experts to understand the situation in a more realistic manner. The primary objective of this paper is to explicate the different components inside the system. To verify the technical feasibility of each component, the proposed system is implemented and tested using ECG data.

  2. The Moli-sani project: computerized ECG database in a population-based cohort study.

    PubMed

    Iacoviello, Licia; Rago, Livia; Costanzo, Simona; Di Castelnuovo, Augusto; Zito, Francesco; Assanelli, Deodato; Badilini, Fabio; Donati, Maria Benedetta; de Gaetano, Giovanni

    2012-01-01

    Computerized electrocardiogram (ECG) acquisition and interpretation may be extremely useful in handling analysis of data from large cohort studies and exploit research on the use of ECG data as prognostic markers for cardiovascular disease. The Moli-sani project (http://www.moli-sani.org) is a population-based cohort study aiming at evaluating the risk factors linked to chronic-degenerative disease with particular regard to cardiovascular disease and cancer and intermediate metabolic phenotypes such as hypertension, diabetes, dyslipidemia, obesity, and metabolic syndrome. Between March 2005 and April 2010, 24 325 people aged 35 years or older, living in the Molise region (Italy), were randomly recruited. A follow-up based on linkage with hospital discharge records and mortality regional registry and reexamination of the cohort is ongoing and will be repeated at prefixed times. Each subject was administered questionnaires on personal and medical history, food consumption, quality of life (FS36), and psychometry. Plasma serum, cellular pellet, and urinary spots were stored in liquid nitrogen. Subjects were measured blood pressure, weight, height, and waist and hip circumferences, and underwent spirometry to evaluate pulmonary diffusion capacity, gas diffusion, and pulmonary volumes. Standard 12-lead resting ECG was performed by a Cardiette ar2100-view electrocardiograph and tracings stored in digital standard communication protocol format for subsequent analysis. The digital ECG database of the Moli-sani project is currently being used to assess the association between physiologic variables and pathophyiosiologic conditions and parameters derived from the ECG signal. This computerized ECG database represents a unique opportunity to identify and assess prognostic factors associated with cardiovascular and metabolic diseases.

  3. An Advanced User Interface Approach for Complex Parameter Study Process Specification in the Information Power Grid

    NASA Technical Reports Server (NTRS)

    Yarrow, Maurice; McCann, Karen M.; Biswas, Rupak; VanderWijngaart, Rob; Yan, Jerry C. (Technical Monitor)

    2000-01-01

    The creation of parameter study suites has recently become a more challenging problem as the parameter studies have now become multi-tiered and the computational environment has become a supercomputer grid. The parameter spaces are vast, the individual problem sizes are getting larger, and researchers are now seeking to combine several successive stages of parameterization and computation. Simultaneously, grid-based computing offers great resource opportunity but at the expense of great difficulty of use. We present an approach to this problem which stresses intuitive visual design tools for parameter study creation and complex process specification, and also offers programming-free access to grid-based supercomputer resources and process automation.

  4. Single frequency RF powered ECG telemetry system

    NASA Technical Reports Server (NTRS)

    Ko, W. H.; Hynecek, J.; Homa, J.

    1979-01-01

    It has been demonstrated that a radio frequency magnetic field can be used to power implanted electronic circuitry for short range telemetry to replace batteries. A substantial reduction in implanted volume can be achieved by using only one RF tank circuit for receiving the RF power and transmitting the telemetered information. A single channel telemetry system of this type, using time sharing techniques, was developed and employed to transmit the ECG signal from Rhesus monkeys in primate chairs. The signal from the implant is received during the period when the RF powering radiation is interrupted. The ECG signal is carried by 20-microsec pulse position modulated pulses, referred to the trailing edge of the RF powering pulse. Satisfactory results have been obtained with this single frequency system. The concept and the design presented may be useful for short-range long-term implant telemetry systems.

  5. Cardiac Repolarization Abnormalities and Potential Evidence for Loss of Cardiac Sodium Currents on ECGs of Patients with Chagas' Heart Disease

    NASA Technical Reports Server (NTRS)

    Schlegel, T. T.; Medina, R.; Jugo, D.; Nunez, T. J.; Borrego, A.; Arellano, E.; Arenare, B.; DePalma, J. L.; Greco, E. C.; Starc, V.

    2007-01-01

    Some individuals with Chagas disease develop right precordial lead ST segment elevation in response to an ajmaline challenge test, and the prevalence of right bundle branch block (RBBB) is also high in Chagas disease. Because these same electrocardiographic abnormalities occur in the Brugada syndrome, which involves genetically defective cardiac sodium channels, acquired damage to cardiac sodium channels may also occur in Chagas disease. We studied several conventional and advanced resting 12-lead/derived Frank-lead ECG parameters in 34 patients with Chagas -related heart disease (mean age 39 14 years) and in 34 age-/gender-matched healthy controls. All ECG recordings were of 5-10 min duration, obtained in the supine position using high fidelity hardware/software (CardioSoft, Houston, TX). Even after excluding those Chagas patients who had resting BBBs, tachycardia and/or pathologic arrhythmia (n=8), significant differences remained in multiple conventional and advanced ECG parameters between the Chagas and control groups (n=26/group), especially in their respective QT interval variability indices, maximal spatial QRS-T angles and low frequency HRV powers (p=0.0006, p=0.0015 and p=0.0314 respectively). In relation to the issue of potential damage to cardiac sodium channels, the Chagas patients had: 1) greater than or equal to twice the incidence of resting ST segment elevation in leads V1-V3 (n=10/26 vs. n=5/26) and of both leftward (n=5/26 versus n=0/26) and rightward (n=7/26 versus n=3/26) QRS axis deviation than controls; 2) significantly increased filtered (40-250 Hz) QRS interval durations (92.1 8.5 versus 85.3 plus or minus 9.0 ms, p=0.022) versus controls; and 3) significantly decreased QT and especially JT interval durations versus controls (QT interval: 387.5 plus or minus 26.4 versus 408.9 plus or minus 34.6 ms, p=0.013; JT interval: 290.5 plus or minus 26.3 versus 314.8 plus or minus 31.3 ms; p=0.0029). Heart rates and Bazett-corrected QTc/JTc intervals

  6. Fractional dynamical model for the generation of ECG like signals from filtered coupled Van-der Pol oscillators.

    PubMed

    Das, Saptarshi; Maharatna, Koushik

    2013-12-01

    In this paper, an incommensurate fractional order (FO) model has been proposed to generate ECG like waveforms. Earlier investigation of ECG like waveform generation is based on two identical Van-der Pol (VdP) family of oscillators, which are coupled by time delays and gains. In this paper, we suitably modify the three state equations corresponding to the nonlinear cross-product of states, time delay coupling of the two oscillators and low-pass filtering, using the concept of fractional derivatives. Our results show that a wide variety of ECG like waveforms can be simulated from the proposed generalized models, characterizing heart conditions under different physiological conditions. Such generalization of the modelling of ECG waveforms may be useful to understand the physiological process behind ECG signal generation in normal and abnormal heart conditions. Along with the proposed FO models, an optimization based approach is also presented to estimate the VdP oscillator parameters for representing a realistic ECG like signal.

  7. Reliability of Left Ventricular Hypertrophy by ECG Criteria in Children with Syncope: Do the Criteria Need to be Revised?

    PubMed

    Banerjee, Maalika M; Ramesh Iyer, V; Nandi, Deipanjan; Vetter, Victoria L; Banerjee, Anirban

    2016-04-01

    In the outpatient setting, children who present with syncope routinely undergo electrocardiograms (ECG). Because of concerns for hypertrophic cardiomyopathy, children with syncope meeting ECG criteria for left ventricular hypertrophy (LVH) will frequently undergo an echocardiogram. Our objectives were to determine whether Davignon criteria for ECG waves overestimate LVH in children presenting with syncope, and to study the usefulness of echocardiography in these children. We hypothesize that the Davignon criteria presently used for interpretation of ECGs overestimate LVH, resulting in unnecessary echocardiography in this clinical setting. The clinical database of The Children's Hospital of Philadelphia was evaluated from 2002 to 2012 to identify children between 9 and 16 years of age, who presented with non-exercise-induced, isolated syncope. From this group of patients, only those with clear-cut evidence of LVH (by Davignon criteria), who also underwent an echocardiogram, were selected. A total of 136 children with syncope were identified as having LVH by Davignon ECG criteria. None of these patients manifested any evidence of hypertrophic cardiomyopathy, with normal ventricular septum (average Z-score -0.68 ± 0.84), LV posterior wall (average Z-score -0.66 ± 1.18) and LV mass (average Z-score 0.52 ± 1.29). No significant correlation was found between summed RV6 plus SV1 and LV mass. Correlations between additional ECG parameters and measures of LVH by echocardiography were similarly poor. In children presenting with syncope and LVH by ECG, there was no evidence of true LVH by echocardiography. We propose that the Davignon ECG criteria for interpreting LVH in children overestimate the degree of hypertrophy in these children and the yield of echocardiography is extremely low.

  8. Community Introduction of Practice Parameters for Autistic Spectrum Disorders: Advancing Early Recognition

    ERIC Educational Resources Information Center

    Holzer, Laurent; Mihailescu, Raluca; Rodrigues-Degaeff, Catherine; Junier, Laurent; Muller-Nix, Carole; Halfon, Oliver; Ansermet, Francois

    2006-01-01

    Objectives: Within a strong interdisciplinary framework, improvement in the quality of care for children with autistic spectrum disorders through a 2 year implementation program of Practice Parameters, aimed principally at improving early detection and intervention. Method: We developed Practice Parameters (PPs) for Pervasive Developmental…

  9. Geolocation of LTE Subscriber Stations Based on the Timing Advance Ranging Parameter

    DTIC Science & Technology

    2010-12-01

    timing advance range rings (From [8]). ..................6 Figure 3. Functional commonality between SC- FDMA and OFDMA signal chains (From [14... FDMA Single Carrier Frequency Division Multiple Access SDU Service Data Unit SS Subscriber Station SVD Singular Value Decomposition TA...uplink and downlink. They are single-carrier frequency-division multiple access (SC- FDMA ) and orthogonal frequency-division multiple access (OFDMA

  10. Microcontroller-based underwater acoustic ECG telemetry system.

    PubMed

    Istepanian, R S; Woodward, B

    1997-06-01

    This paper presents a microcontroller-based underwater acoustic telemetry system for digital transmission of the electrocardiogram (ECG). The system is designed for the real time, through-water transmission of data representing any parameter, and it was used initially for transmitting in multiplexed format the heart rate, breathing rate and depth of a diver using self-contained underwater breathing apparatus (SCUBA). Here, it is used to monitor cardiovascular reflexes during diving and swimming. The programmable capability of the system provides an effective solution to the problem of transmitting data in the presence of multipath interference. An important feature of the paper is a comparative performance analysis of two encoding methods, Pulse Code Modulation (PCM) and Pulse Position Modulation (PPM).

  11. A model-based approach to human identification using ECG

    NASA Astrophysics Data System (ADS)

    Homer, Mark; Irvine, John M.; Wendelken, Suzanne

    2009-05-01

    Biometrics, such as fingerprint, iris scan, and face recognition, offer methods for identifying individuals based on a unique physiological measurement. Recent studies indicate that a person's electrocardiogram (ECG) may also provide a unique biometric signature. Current techniques for identification using ECG rely on empirical methods for extracting features from the ECG signal. This paper presents an alternative approach based on a time-domain model of the ECG trace. Because Auto-Regressive Integrated Moving Average (ARIMA) models form a rich class of descriptors for representing the structure of periodic time series data, they are well-suited to characterizing the ECG signal. We present a method for modeling the ECG, extracting features from the model representation, and identifying individuals using these features.

  12. Compressed domain ECG biometric with two-lead features

    NASA Astrophysics Data System (ADS)

    Lee, Wan-Jou; Chang, Wen-Whei

    2016-07-01

    This study presents a new method to combine ECG biometrics with data compression within a common JPEG2000 framework. We target the two-lead ECG configuration that is routinely used in long-term heart monitoring. Incorporation of compressed-domain biometric techniques enables faster person identification as it by-passes the full decompression. Experiments on public ECG databases demonstrate the validity of the proposed method for biometric identification with high accuracies on both healthy and diseased subjects.

  13. Denoising of ECG signal during spaceflight using singular value decomposition

    NASA Astrophysics Data System (ADS)

    Li, Zhuo; Wang, Li

    2009-12-01

    The Singular Value Decomposition (SVD) method is introduced to denoise the ECG signal during spaceflight. The theory base of SVD method is given briefly. The denoising process of the strategy is presented combining a segment of real ECG signal. We improve the algorithm of calculating Singular Value Ratio (SVR) spectrum, and propose a constructive approach of analysis characteristic patterns. We reproduce the ECG signal very well and compress the noise effectively. The SVD method is proved to be suitable for denoising the ECG signal.

  14. Arrhythmia ECG Noise Reduction by Ensemble Empirical Mode Decomposition

    PubMed Central

    Chang, Kang-Ming

    2010-01-01

    A novel noise filtering algorithm based on ensemble empirical mode decomposition (EEMD) is proposed to remove artifacts in electrocardiogram (ECG) traces. Three noise patterns with different power—50 Hz, EMG, and base line wander – were embedded into simulated and real ECG signals. Traditional IIR filter, Wiener filter, empirical mode decomposition (EMD) and EEMD were used to compare filtering performance. Mean square error between clean and filtered ECGs was used as filtering performance indexes. Results showed that high noise reduction is the major advantage of the EEMD based filter, especially on arrhythmia ECGs. PMID:22219702

  15. 3-lead acquisition using single channel ECG device developed on AD8232 analog front end for wireless ECG application

    NASA Astrophysics Data System (ADS)

    Agung, Mochammad Anugrah; Basari

    2017-02-01

    Electrocardiogram (ECG) devices measure electrical activity of the heart muscle to determine heart conditions. ECG signal quality is the key factor in determining the diseases of the heart. This paper presents the design of 3-lead acquistion on single channel wireless ECG device developed on AD8232 chip platform using microcontroller. To make the system different from others, monopole antenna 2.4 GHz is used in order to send and receive ECG signal. The results show that the system still can receive ECG signal up to 15 meters by line of sight (LOS) condition. The shape of ECG signals is precisely similar with the expected signal, although some delays occur between two consecutive pulses. For further step, the system will be applied with on-body antenna in order to investigate body to body communication that will give variation in connectivity from the others.

  16. Scoring of Prognostic Parameters in Patients with Unresectable Advanced or Recurrent Colorectal Cancer Undergoing Chemotherapy

    PubMed Central

    Ikeguchi, Masahide; Shimoda, Ryugo; Yamamoto, Manabu; Maeta, Yoshihiko; Ashida, Keigo; Saito, Hiroaki

    2013-01-01

    Background Suitable chemotherapy is needed to prolong the survival of patients with unresectable advanced or recurrent colorectal cancer. We scored the periodical changes of several prognostic markers during chemotherapy in patients with this type of cancer to discern the effectiveness of chemotherapy. Methods Twenty consecutive patients with unresectable advanced or recurrent colorectal cancer were enrolled. All patients underwent combination chemotherapy with oxaliplatin or irinotecan plus 5-fluorouracil/leucovorin. Neutrophil/lymphocyte ratio (NLR), serum C-reactive protein (CRP), serum carcinoembryonic antigen (CEA) and serum albumin (ALB) were compared between the two periods (before chemotherapy and 3 months after it was started) in each patient. The scoring system was as follows: points are added when a patient shows a decrease of NLR, CRP and CEA and an increase of ALB at 3 months after the start of chemotherapy with a possible final score of +4. On the other hand, points are reduced if a patient shows an elevation of NLR, CRP and CEA and a decrease of ALB at 3 months after the start of chemotherapy with a possible final score of −4. Results At 3 months after the start of first line chemotherapy, 13 patients showed positive scores but 7 patients showed zero or minus scores. According to our scoring system, we found the mean survival time (MST) of the 13 patients with plus scores was 34 months and this was significantly better than that of the 7 patients who showed zero or minus scores (P = 0.0008). Conclusion Our new scoring system is useful but when we find that first line chemotherapy is ineffective, we need to change it to second line chemotherapy as soon as possible. That may be the best treatment for patients with unresectable advanced or recurrent colorectal cancer. PMID:24179314

  17. Effect of advanced uncomplicated pregnancy on pulmonary function parameters of North Indian subjects.

    PubMed

    Neeraj; Sodhi, Candy; Pramod, John; Singh, Joydeep; Kaur, Vaneet

    2010-01-01

    The study was conducted on 100 pregnant women in third trimester of uncomplicated pregnancy (Test group) and 100 age-matched non-pregnant women (Control group) in the age group of 25 to 35 years. Pulmonary function test parameters FVC, FEV1, PEFR and FEF25-75% recorded using Medspiror. The FEV1/FVC ratio was calculated. All parameters except FEV1/ FVC ratio were found to decline in the Test group as compared to the Control group. The decrease in FEV1 with pregnancy was not of such amplitude as decrease in FVC, and hence FEV1/FVC ratio was seen to increase. This study validates the physiological changes in pulmonary function brought by pregnancy and highlights the need to compile expected and accepted alterations in predicted values of PFT in comparison with the non gravid states for safer outcome of the pregnancy.

  18. Sensitivity derivatives for advanced CFD algorithm and viscous modelling parameters via automatic differentiation

    NASA Technical Reports Server (NTRS)

    Green, Lawrence L.; Newman, Perry A.; Haigler, Kara J.

    1993-01-01

    The computational technique of automatic differentiation (AD) is applied to a three-dimensional thin-layer Navier-Stokes multigrid flow solver to assess the feasibility and computational impact of obtaining exact sensitivity derivatives typical of those needed for sensitivity analyses. Calculations are performed for an ONERA M6 wing in transonic flow with both the Baldwin-Lomax and Johnson-King turbulence models. The wing lift, drag, and pitching moment coefficients are differentiated with respect to two different groups of input parameters. The first group consists of the second- and fourth-order damping coefficients of the computational algorithm, whereas the second group consists of two parameters in the viscous turbulent flow physics modelling. Results obtained via AD are compared, for both accuracy and computational efficiency with the results obtained with divided differences (DD). The AD results are accurate, extremely simple to obtain, and show significant computational advantage over those obtained by DD for some cases.

  19. Development of advanced techniques for rotorcraft state estimation and parameter identification

    NASA Technical Reports Server (NTRS)

    Hall, W. E., Jr.; Bohn, J. G.; Vincent, J. H.

    1980-01-01

    An integrated methodology for rotorcraft system identification consists of rotorcraft mathematical modeling, three distinct data processing steps, and a technique for designing inputs to improve the identifiability of the data. These elements are as follows: (1) a Kalman filter smoother algorithm which estimates states and sensor errors from error corrupted data. Gust time histories and statistics may also be estimated; (2) a model structure estimation algorithm for isolating a model which adequately explains the data; (3) a maximum likelihood algorithm for estimating the parameters and estimates for the variance of these estimates; and (4) an input design algorithm, based on a maximum likelihood approach, which provides inputs to improve the accuracy of parameter estimates. Each step is discussed with examples to both flight and simulated data cases.

  20. Fault detection in heavy duty wheels by advanced vibration processing techniques and lumped parameter modeling

    NASA Astrophysics Data System (ADS)

    Malago`, M.; Mucchi, E.; Dalpiaz, G.

    2016-03-01

    Heavy duty wheels are used in applications such as automatic vehicles and are mainly composed of a polyurethane tread glued to a cast iron hub. In the manufacturing process, the adhesive application between tread and hub is a critical assembly phase, since it is completely made by an operator and a contamination of the bond area may happen. Furthermore, the presence of rust on the hub surface can contribute to worsen the adherence interface, reducing the operating life. In this scenario, a quality control procedure for fault detection to be used at the end of the manufacturing process has been developed. This procedure is based on vibration processing techniques and takes advantages of the results of a lumped parameter model. Indicators based on cyclostationarity can be considered as key parameters to be adopted in a monitoring test station at the end of the production line due to their not deterministic characteristics.

  1. Parameter identification studies on the NASA/Ames Research Center Advanced Concepts Flight Simulator. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Mckavitt, Thomas P., Jr.

    1990-01-01

    The results of an aircraft parameters identification study conducted on the National Aeronautics and Space Administration/Ames Research Center Advanced Concepts Flight Simulator (ACFS) in conjunction with the Navy-NASA Joint Institute of Aeronautics are given. The ACFS is a commercial airline simulator with a design based on future technology. The simulator is used as a laboratory for human factors research and engineering as applied to the commercial airline industry. Parametric areas examined were engine pressure ratio (EPR), optimum long range cruise Mach number, flap reference speed, and critical take-off speeds. Results were compared with corresponding parameters of the Boeing 757 and 767 aircraft. This comparison identified two areas where improvements can be made: (1) low maximum lift coefficients (on the order of 20-25 percent less than those of a 757); and (2) low optimum cruise Mach numbers. Recommendations were made to those anticipated with the application of future technologies.

  2. Exploring the impact of Advanced LIGO transient noise on the estimation of astrophysical parameters of binary black hole coalescences

    NASA Astrophysics Data System (ADS)

    McIver, Jessica; LIGO Scientific Collaboration

    2017-01-01

    The Advanced LIGO detectors have unprecedented sensitivity to the spacetime strain induced by gravitational waves, but the interferometer data are non-stationary. Instrumental and environmental transient noise artifacts, or `glitches', occur frequently in the data and can mimic transient gravitational wave signals, including compact binary coalescences (CBCs). In addition to limiting the sensitivity of gravitational wave searches, in cases when astrophysical signals occur during or near periods of transient noise, this noise can also contaminate the estimation of the astrophysical parameters of CBC sources, such as spin, mass, and sky location. I will show the rate and common morphologies of transient noise in LIGO data and illustrate the impact of common classes of transient noise on the parameter estimation of observable binary black hole merger signals.

  3. A novel biometric authentication approach using ECG and EMG signals.

    PubMed

    Belgacem, Noureddine; Fournier, Régis; Nait-Ali, Amine; Bereksi-Reguig, Fethi

    2015-05-01

    Security biometrics is a secure alternative to traditional methods of identity verification of individuals, such as authentication systems based on user name and password. Recently, it has been found that the electrocardiogram (ECG) signal formed by five successive waves (P, Q, R, S and T) is unique to each individual. In fact, better than any other biometrics' measures, it delivers proof of subject's being alive as extra information which other biometrics cannot deliver. The main purpose of this work is to present a low-cost method for online acquisition and processing of ECG signals for person authentication and to study the possibility of providing additional information and retrieve personal data from an electrocardiogram signal to yield a reliable decision. This study explores the effectiveness of a novel biometric system resulting from the fusion of information and knowledge provided by ECG and EMG (Electromyogram) physiological recordings. It is shown that biometrics based on these ECG/EMG signals offers a novel way to robustly authenticate subjects. Five ECG databases (MIT-BIH, ST-T, NSR, PTB and ECG-ID) and several ECG signals collected in-house from volunteers were exploited. A palm-based ECG biometric system was developed where the signals are collected from the palm of the subject through a minimally intrusive one-lead ECG set-up. A total of 3750 ECG beats were used in this work. Feature extraction was performed on ECG signals using Fourier descriptors (spectral coefficients). Optimum-Path Forest classifier was used to calculate the degree of similarity between individuals. The obtained results from the proposed approach look promising for individuals' authentication.

  4. Robust quantitative parameter estimation by advanced CMP measurements for vadose zone hydrological studies

    NASA Astrophysics Data System (ADS)

    Koyama, C.; Wang, H.; Khuut, T.; Kawai, T.; Sato, M.

    2015-12-01

    Soil moisture plays a crucial role in the understanding of processes in the vadose zone hydrology. In the last two decades ground penetrating radar (GPR) has been widely discussed has nondestructive measurement technique for soil moisture data. Especially the common mid-point (CMP) technique, which has been used in both seismic and GPR surveys to investigate the vertical velocity profiles, has a very high potential for quantitaive obervsations from the root zone to the ground water aquifer. However, the use is still rather limited today and algorithms for robust quantitative paramter estimation are lacking. In this study we develop an advanced processing scheme for operational soil moisture reetrieval at various depth. Using improved signal processing, together with a semblance - non-normalized cross-correlation sum combined stacking approach and the Dix formula, the interval velocities for multiple soil layers are obtained from the RMS velocities allowing for more accurate estimation of the permittivity at the reflecting point. Where the presence of a water saturated layer, like a groundwater aquifer, can be easily identified by its RMS velocity due to the high contrast compared to the unsaturated zone. By using a new semi-automated measurement technique the acquisition time for a full CMP gather with 1 cm intervals along a 10 m profile can be reduced significantly to under 2 minutes. The method is tested and validated under laboratory conditions in a sand-pit as well as on agricultural fields and beach sand in the Sendai city area. Comparison between CMP estimates and TDR measurements yield a very good agreement with RMSE of 1.5 Vol.-%. The accuracy of depth estimation is validated with errors smaller than 2%. Finally, we demonstrate application of the method in a test site in semi-arid Mongolia, namely the Orkhon River catchment in Bulgan, using commercial 100 MHz and 500 MHz RAMAC GPR antennas. The results demonstrate the suitability of the proposed method for

  5. 3D Finite Element Electrical Model of Larval Zebrafish ECG Signals.

    PubMed

    Crowcombe, James; Dhillon, Sundeep Singh; Hurst, Rhiannon Mary; Egginton, Stuart; Müller, Ferenc; Sík, Attila; Tarte, Edward

    2016-01-01

    Assessment of heart function in zebrafish larvae using electrocardiography (ECG) is a potentially useful tool in developing cardiac treatments and the assessment of drug therapies. In order to better understand how a measured ECG waveform is related to the structure of the heart, its position within the larva and the position of the electrodes, a 3D model of a 3 days post fertilisation (dpf) larval zebrafish was developed to simulate cardiac electrical activity and investigate the voltage distribution throughout the body. The geometry consisted of two main components; the zebrafish body was modelled as a homogeneous volume, while the heart was split into five distinct regions (sinoatrial region, atrial wall, atrioventricular band, ventricular wall and heart chambers). Similarly, the electrical model consisted of two parts with the body described by Laplace's equation and the heart using a bidomain ionic model based upon the Fitzhugh-Nagumo equations. Each region of the heart was differentiated by action potential (AP) parameters and activation wave conduction velocities, which were fitted and scaled based on previously published experimental results. ECG measurements in vivo at different electrode recording positions were then compared to the model results. The model was able to simulate action potentials, wave propagation and all the major features (P wave, R wave, T wave) of the ECG, as well as polarity of the peaks observed at each position. This model was based upon our current understanding of the structure of the normal zebrafish larval heart. Further development would enable us to incorporate features associated with the diseased heart and hence assist in the interpretation of larval zebrafish ECGs in these conditions.

  6. ECG is an inefficient screening-tool for left ventricular hypertrophy in normotensive African children population

    PubMed Central

    Creta, Antonio; Campanale, Cosimo Marco; Fittipaldi, Mario; Giorgino, Riccardo; Quintarelli, Fabio; Satriano, Umberto; Cruciani, Alessandro; Antinolfi, Vincenzo; Di Berardino, Stefano; Costanzo, Davide; Bettini, Ranieri; Mangiameli, Giuseppe; Caricato, Marco; Mottini, Giovanni

    2016-01-01

    Background Left ventricular hypertrophy (LVH) is a marker of pediatric hypertension and predicts development of cardiovascular events. Electrocardiography (ECG) screening is used in pediatrics to detect LVH thanks to major accessibility, reproducibility and easy to use compared to transthoracic echocardiography (TTE), that remains the standard technique. Several diseases were previously investigated, but no data exists regarding our study population. The aim of our study was to evaluate the relationship between electrocardiographic and echocardiographic criteria of LVH in normotensive African children. Methods We studied 313 children (mean age 7,8 ± 3 yo), in north-Madagascar. They underwent ECG and TTE. Sokolow-Lyon index was calculated to identify ECG-LVH (>35 mm). Left ventricle mass (LVM) with TTE was calculated and indexed by height2.7 (LVMI2.7) and weight (LVMIw). We report the prevalence of TTE-LVH using three methods: (1) calculating percentiles age- and sex- specific with values >95th percentile identifying LVH; (2) LVMI2.7 >51 g/m2.7; (3) LVMIw >3.4 g/weight. Results 40 (13%) children showed LVMI values >95th percentile, 24 children (8%) an LVMI2.7 >51 g/m2.7 while 19 children (6%) an LVMIw >3.4 g/kg. LVH-ECG by Sokolow-Lyon index was present in five, three and three children respectively, with poor values of sensitivity (ranging from 13 to 16%), positive predictive value (from 11 to 18%) and high values of specificity (up to 92%). The effects of anthropometrics parameters on Sokolow-Lyon were analyzed and showed poor correlation. Conclusion ECG is a poor screening test for detecting LVH in children. In clinical practice, TTE remains the only tool to be used to exclude LVH. PMID:27651998

  7. 3D Finite Element Electrical Model of Larval Zebrafish ECG Signals

    PubMed Central

    Crowcombe, James; Dhillon, Sundeep Singh; Hurst, Rhiannon Mary; Egginton, Stuart; Müller, Ferenc; Sík, Attila; Tarte, Edward

    2016-01-01

    Assessment of heart function in zebrafish larvae using electrocardiography (ECG) is a potentially useful tool in developing cardiac treatments and the assessment of drug therapies. In order to better understand how a measured ECG waveform is related to the structure of the heart, its position within the larva and the position of the electrodes, a 3D model of a 3 days post fertilisation (dpf) larval zebrafish was developed to simulate cardiac electrical activity and investigate the voltage distribution throughout the body. The geometry consisted of two main components; the zebrafish body was modelled as a homogeneous volume, while the heart was split into five distinct regions (sinoatrial region, atrial wall, atrioventricular band, ventricular wall and heart chambers). Similarly, the electrical model consisted of two parts with the body described by Laplace’s equation and the heart using a bidomain ionic model based upon the Fitzhugh-Nagumo equations. Each region of the heart was differentiated by action potential (AP) parameters and activation wave conduction velocities, which were fitted and scaled based on previously published experimental results. ECG measurements in vivo at different electrode recording positions were then compared to the model results. The model was able to simulate action potentials, wave propagation and all the major features (P wave, R wave, T wave) of the ECG, as well as polarity of the peaks observed at each position. This model was based upon our current understanding of the structure of the normal zebrafish larval heart. Further development would enable us to incorporate features associated with the diseased heart and hence assist in the interpretation of larval zebrafish ECGs in these conditions. PMID:27824910

  8. Smart Helmet: Wearable Multichannel ECG and EEG

    PubMed Central

    Chanwimalueang, Theerasak; Goverdovsky, Valentin; Looney, David; Sharp, David; Mandic, Danilo P.

    2016-01-01

    Modern wearable technologies have enabled continuous recording of vital signs, however, for activities such as cycling, motor-racing, or military engagement, a helmet with embedded sensors would provide maximum convenience and the opportunity to monitor simultaneously both the vital signs and the electroencephalogram (EEG). To this end, we investigate the feasibility of recording the electrocardiogram (ECG), respiration, and EEG from face-lead locations, by embedding multiple electrodes within a standard helmet. The electrode positions are at the lower jaw, mastoids, and forehead, while for validation purposes a respiration belt around the thorax and a reference ECG from the chest serve as ground truth to assess the performance. The within-helmet EEG is verified by exposing the subjects to periodic visual and auditory stimuli and screening the recordings for the steady-state evoked potentials in response to these stimuli. Cycling and walking are chosen as real-world activities to illustrate how to deal with the so-induced irregular motion artifacts, which contaminate the recordings. We also propose a multivariate R-peak detection algorithm suitable for such noisy environments. Recordings in real-world scenarios support a proof of concept of the feasibility of recording vital signs and EEG from the proposed smart helmet. PMID:27957405

  9. Development of advanced techniques for identification of flow stress and friction parameters for metal forming analysis

    NASA Astrophysics Data System (ADS)

    Cho, Hyunjoong

    The accuracy of process simulation in metal forming by finite element method depends on the accuracy of flow stress data and friction value that are input to FEM programs. Therefore, it is essential that these input values are determined using reliable tests and evaluation methods. This study presents the development of inverse analysis methodology and its application to determine flow stress data of bulk and sheet materials at room and elevated temperatures. The inverse problem is defined as the minimization of the differences between the experimental measurements and the corresponding FEM predictions. Rigid-viscoplastic FEM is used to analyze the metal flow while a numerical optimization algorithm adjusts the material parameters used in the simulation until the calculated response matches the measured data within a specified tolerance. The use of the developed inverse analysis methodology has been demonstrated by applying it to the selected reference rheological tests; cylinder compression test, ring compression test, instrumented indentation test, modified limiting dome height test, and sheet hydraulic bulge test. Furthermore, using the determined material property data, full 3-D finite element simulation models, as examples of industrial applications for orbital forming and thermoforming processes have been developed for reliable process simulation. As results of this study, it was shown that the developed inverse analysis methodology could identify both the material parameters and friction factors from one set of tests, simultaneously. Therefore, this technique can offer a systematic and cost effective way for determining material property data for simulation of metal forming processes.

  10. Human ECG indicators for fast screening and evaluation

    NASA Astrophysics Data System (ADS)

    Maciejewski, Marcin; DzierŻak, RóŻa; Surtel, Wojciech; Saran, Tomasz

    2016-09-01

    Telemedical system design and implementation requires numerous steps. It is necessary to evaluate the operation of algorithms responsible for analysis and detection of life-threatening situations. By performing ECG analysis it is possible to obtain information about the overall patient health condition as well as detailed information about the circulatory system condition. To achieve that goal one must gather, filter and process data. Data was gathered using a purposely built device from a group of four volunteers. Available data set was processed to obtain information about the patients condition. Pan-Tompkins algorithm was used to detect R peaks and calculate heart rhythm. Afterward the rest of parameters were extracted in time domain using windowed peak detection and polynomial estimation. The parameters were calculated as delays between appropriate points in the signal. The method proved to be able to extract parameters in some of the cases, and proved limited effectiveness in situations where physical activity was significant. It was nevertheless possible to eliminate noise from the mains, the trend and higher frequency noise Further improvements need to be introduced to increase the method's robustness in the presence of significant muscle noise.

  11. The influence of fluorouracil outcome parameters on tolerance and efficacy in patients with advanced colorectal cancer.

    PubMed

    Capitain, O; Boisdron-Celle, M; Poirier, A-L; Abadie-Lacourtoisie, S; Morel, A; Gamelin, E

    2008-08-01

    The purpose of this study was to determine simple genetic factors helpful to tailor 5-FU administration and determine strategy in first-line chemotherapy of advanced colorectal cancer. In 76 patients initially treated by 5-FU, thymidylate synthase, dihydropyrimidine dehydrogenase and methylene tetrahydrofolate reductase germinal polymorphisms, dihydrouracil/uracil plasma ratio and 5-FU plasma clearance were investigated and correlated for tolerance (10.5% grade 3 and 4 toxicity) and efficacy (32.9% objective response rate and 20 months median overall survival time). Toxicity was linked to performance status >2 (P=0.004), low UH2/U ratio, 2846 A>T, IVS 14+1G>A for DPD (P=0.031), and homozygoty C/C for MTHFR 1298 A>C (P=0.0018). The overall survival of the patients with a 3R/3R TS genotype associated with C/C for 677 C>T or A/A for 1298 A>C was statistically shorter (log-rank test P=0.0065). Genetic factors permit the tailoring of 5-FU treatment. They should occupy center stage in future clinical trials for specifically designing treatment for patients with a given biologic feature.

  12. A novel similarity comparison approach for dynamic ECG series.

    PubMed

    Yin, Hong; Zhu, Xiaoqian; Ma, Shaodong; Yang, Shuqiang; Chen, Liqian

    2015-01-01

    The heart sound signal is a reflection of heart and vascular system motion. Long-term continuous electrocardiogram (ECG) contains important information which can be helpful to prevent heart failure. A single piece of a long-term ECG recording usually consists of more than one hundred thousand data points in length, making it difficult to derive hidden features that may be reflected through dynamic ECG monitoring, which is also very time-consuming to analyze. In this paper, a Dynamic Time Warping based on MapReduce (MRDTW) is proposed to make prognoses of possible lesions in patients. Through comparison of a real-time ECG of a patient with the reference sets of normal and problematic cardiac waveforms, the experimental results reveal that our approach not only retains high accuracy, but also greatly improves the efficiency of the similarity measure in dynamic ECG series.

  13. ECG Signal Analysis and Arrhythmia Detection using Wavelet Transform

    NASA Astrophysics Data System (ADS)

    Kaur, Inderbir; Rajni, Rajni; Marwaha, Anupma

    2016-12-01

    Electrocardiogram (ECG) is used to record the electrical activity of the heart. The ECG signal being non-stationary in nature, makes the analysis and interpretation of the signal very difficult. Hence accurate analysis of ECG signal with a powerful tool like discrete wavelet transform (DWT) becomes imperative. In this paper, ECG signal is denoised to remove the artifacts and analyzed using Wavelet Transform to detect the QRS complex and arrhythmia. This work is implemented in MATLAB software for MIT/BIH Arrhythmia database and yields the sensitivity of 99.85 %, positive predictivity of 99.92 % and detection error rate of 0.221 % with wavelet transform. It is also inferred that DWT outperforms principle component analysis technique in detection of ECG signal.

  14. A method of ECG template extraction for biometrics applications.

    PubMed

    Zhou, Xiang; Lu, Yang; Chen, Meng; Bao, Shu-Di; Miao, Fen

    2014-01-01

    ECG has attracted widespread attention as one of the most important non-invasive physiological signals in healthcare-system related biometrics for its characteristics like ease-of-monitoring, individual uniqueness as well as important clinical value. This study proposes a method of dynamic threshold setting to extract the most stable ECG waveform as the template for the consequent ECG identification process. With the proposed method, the accuracy of ECG biometrics using the dynamic time wraping for difference measures has been significantly improved. Analysis results with the self-built electrocardiogram database show that the deployment of the proposed method was able to reduce the half total error rate of the ECG biometric system from 3.35% to 1.45%. Its average running time on the platform of android mobile terminal was around 0.06 seconds, and thus demonstrates acceptable real-time performance.

  15. Smart ECG Monitoring Patch with Built-in R-Peak Detection for Long-Term HRV Analysis.

    PubMed

    Lee, W K; Yoon, H; Park, K S

    2016-07-01

    Since heart rate variability (HRV) analysis is widely used to evaluate the physiological status of the human body, devices specifically designed for such applications are needed. To this end, we developed a smart electrocardiography (ECG) patch. The smart patch measures ECG using three electrodes integrated into the patch, filters the measured signals to minimize noise, performs analog-to-digital conversion, and detects R-peaks. The measured raw ECG data and the interval between the detected R-peaks can be recorded to enable long-term HRV analysis. Experiments were performed to evaluate the performance of the built-in R-wave detection, robustness of the device under motion, and applicability to the evaluation of mental stress. The R-peak detection results obtained with the device exhibited a sensitivity of 99.29%, a positive predictive value of 100.00%, and an error of 0.71%. The device also exhibited less motional noise than conventional ECG recording, being stable up to a walking speed of 5 km/h. When applied to mental stress analysis, the device evaluated the variation in HRV parameters in the same way as a normal ECG, with very little difference. This device can help users better understand their state of health and provide physicians with more reliable data for objective diagnosis.

  16. Sequential Total Variation Denoising for the Extraction of Fetal ECG from Single-Channel Maternal Abdominal ECG

    PubMed Central

    Lee, Kwang Jin; Lee, Boreom

    2016-01-01

    Fetal heart rate (FHR) is an important determinant of fetal health. Cardiotocography (CTG) is widely used for measuring the FHR in the clinical field. However, fetal movement and blood flow through the maternal blood vessels can critically influence Doppler ultrasound signals. Moreover, CTG is not suitable for long-term monitoring. Therefore, researchers have been developing algorithms to estimate the FHR using electrocardiograms (ECGs) from the abdomen of pregnant women. However, separating the weak fetal ECG signal from the abdominal ECG signal is a challenging problem. In this paper, we propose a method for estimating the FHR using sequential total variation denoising and compare its performance with that of other single-channel fetal ECG extraction methods via simulation using the Fetal ECG Synthetic Database (FECGSYNDB). Moreover, we used real data from PhysioNet fetal ECG databases for the evaluation of the algorithm performance. The R-peak detection rate is calculated to evaluate the performance of our algorithm. Our approach could not only separate the fetal ECG signals from the abdominal ECG signals but also accurately estimate the FHR. PMID:27376296

  17. Wavelet-based low-delay ECG compression algorithm for continuous ECG transmission.

    PubMed

    Kim, Byung S; Yoo, Sun K; Lee, Moon H

    2006-01-01

    The delay performance of compression algorithms is particularly important when time-critical data transmission is required. In this paper, we propose a wavelet-based electrocardiogram (ECG) compression algorithm with a low delay property for instantaneous, continuous ECG transmission suitable for telecardiology applications over a wireless network. The proposed algorithm reduces the frame size as much as possible to achieve a low delay, while maintaining reconstructed signal quality. To attain both low delay and high quality, it employs waveform partitioning, adaptive frame size adjustment, wavelet compression, flexible bit allocation, and header compression. The performances of the proposed algorithm in terms of reconstructed signal quality, processing delay, and error resilience were evaluated using the Massachusetts Institute of Technology University and Beth Israel Hospital (MIT-BIH) and Creighton University Ventricular Tachyarrhythmia (CU) databases and a code division multiple access-based simulation model with mobile channel noise.

  18. Plasma Impedance Spectrum Analyzer (PISA): an advanced impedance probe for measuring plasma density and other parameters

    NASA Astrophysics Data System (ADS)

    Rowland, D. E.; Pfaff, R. F.; Uribe, P.; Burchill, J.

    2006-12-01

    High-accuracy, high-cadence measurements of ionospheric electron density between 100 and a few x 106 / cc and electron temperature from 200 K to a few thousand K are of critical importance for understanding conductivity, Joule heating rates, and instability growth rates. We present results from the development of an impedance probe at NASA GSFC and show its strengths relative to other measurement techniques. Complementary measurement techniques such as Langmuir Probes, while providing extremely high measurement cadence, suffer from uncertainties in calibration, surface contamination effects, and wake/sheath effects. Impedance Probes function by measuring the phase shift between the voltage on a long antenna and the current flowing from the antenna into the plasma as a function of frequency. At frequencies for which the phase shift is zero, a plasma resonance is assumed to exist. These resonances depend on a variety of plasma parameters, including the electron density, electron temperature, and magnetic field strength, as well as the antenna geometry, angle between the antenna and the magnetic field, and sheath / Debye length effects, but do not depend on the surface properties of the antenna. Previous impedance probe designs which "lock" onto the upper hybrid resonance are susceptible to losing lock in low-density environments. Information about other resonances, including the series resonance (which strongly depends on temperature) and other resonances which may occur near the upper hybrid, confounding its identification, are typically not transmitted. The novel features of the GSFC Impedance Probe (PISA) include: 1) A white noise generator that stimulates a wide range of frequencies simultaneously, allowing the instrument to send down the entire impedance frequency spectrum every few milliseconds. This allows identification of all resonance frequencies, including the series resonance which depends on temperature. 2) DC bias voltage stepping to bring the antenna

  19. Wearable real-time ecg monitoring with emergency alert system for scuba diving.

    PubMed

    Cibis, Tobias; Groh, Benjamin H; Gatermann, Heike; Leutheuser, Heike; Eskofier, Bjoern M

    2015-01-01

    Medical diagnosis is the first level for recognition and treatment of diseases. To realize fast diagnosis, we propose a concept of a basic framework for the underwater monitoring of a diver's ECG signal, including an alert system that warns the diver of predefined medical emergency situations. The framework contains QRS detection, heart rate calculation and an alert system. After performing a predefined study protocol, the algorithm's accuracy was evaluated with 10 subjects in a dry environment and with 5 subjects in an underwater environment. The results showed that, in 3 out of 5 dives as well as in dry environment, data transmission remained stable. In these cases, the subjects were able to trigger the alert system. The evaluated data showed a clear ECG signal with a QRS detection accuracy of 90 %. Thus, the proposed framework has the potential to detect and to warn of health risks. Further developments of this sample concept can imply an extension for monitoring different biomedical parameters.

  20. Preliminary results from BCG and ECG measurements in the heart failure clinic.

    PubMed

    Giovangrandi, Laurent; Inan, Omer T; Banerjee, Dipanjan; Kovacs, Gregory T A

    2012-01-01

    We report on the preliminary deployment of a bathroom scale-based ballistocardiogram (BCG) system for the in-hospital monitoring of patients with heart failure. These early trials provided valuable insights into the challenges and opportunities for such monitoring. In particular, the need for robust algorithms and adapted BCG metric is suggested. The system was designed to be robust and user-friendly, with dual ballistocardiogram (BCG) and electrocardiogram (ECG) capabilities. The BCG was measured from a modified bathroom scale, while the ECG (used as timing reference) was measured using dry handlebar electrodes. The signal conditioning and digitization circuits were USB-powered, and data acquisition performed using a netbook. Four patients with a NYHA class III at admission were measured daily for the duration of their treatment at Stanford hospital. A measure of BCG quality, in essence a quantitative implementation of the BCG classes originally defined in the 1950s, is proposed as a practical parameter.

  1. Effect of Head-Down Bed Rest and Artificial Gravity Countermeasure on Cardiac Autonomic and Advanced Electrocardiographic Function

    NASA Technical Reports Server (NTRS)

    Schlegel, T. T.; Platts, S.; Stenger, M.; Ribeiro, C.; Natapoff, A.; Howarth, M.; Evans, J.

    2007-01-01

    To study the effects of 21 days of head-down bed rest (HDBR), with versus without an artificial gravity (AG) countermeasure, on cardiac autonomic and advanced electrocardiographic function. Fourteen healthy men participated in the study: seven experienced 21 days of HDBR alone ("HDBR controls") and seven the same degree and duration of HDBR but with approximately 1hr daily short-arm centrifugation as an AG countermeasure ("AG-treated"). Five minute supine high-fidelity 12-lead ECGs were obtained in all subjects: 1) 4 days before HDBR; 2) on the last day of HDBR; and 3) 7 days after HDBR. Besides conventional 12-lead ECG intervals and voltages, all of the following advanced ECG parameters were studied: 1) both stochastic (time and frequency domain) and deterministic heart rate variability (HRV); 2) beat-to-beat QT interval variability (QTV); 3) T-wave morphology, including signal-averaged T-wave residua (TWR) and principal component analysis ratios; 4) other SAECG-related parameters including high frequency QRS ECG and late potentials; and 5) several advanced ECG estimates of left ventricular (LV) mass. The most important results by repeated measures ANOVA were that: 1) Heart rates, Bazett-corrected QTc intervals, TWR, LF/HF power and the alpha 1 of HRV were significantly increased in both groups (i.e., by HDBR), but with no relevant HDBR*group differences; 2) All purely "vagally-mediated" parameters of HRV (e.g., RMSSD, HF power, Poincare SD1, etc.), PR intervals, and also several parameters of LV mass (Cornell and Sokolow-Lyon voltages, spatial ventricular activation times, ventricular gradients) were all significantly decreased in both groups (i.e., by HDBR), but again with no relevant HDBR*group differences); 3) All "generalized" or "vagal plus sympathetic" parameters of stochastic HRV (i.e., SDNN, total power, LF power) were significantly more decreased in the AG-treated group than in the HDBR-only group (i.e., here there was a relevant HDBR*group difference

  2. Optimization of Process Parameters for High Efficiency Laser Forming of Advanced High Strength Steels within Metallurgical Constraints

    NASA Astrophysics Data System (ADS)

    Sheikholeslami, Ghazal; Griffiths, Jonathan; Dearden, Geoff; Edwardson, Stuart P.

    Laser forming (LF) has been shown to be a viable alternative to form automotive grade advanced high strength steels (AHSS). Due to their high strength, heat sensitivity and low conventional formability show early fractures, larger springback, batch-to-batch inconsistency and high tool wear. In this paper, optimisation of the LF process parameters has been conducted to further understand the impact of a surface heat treatment on DP1000. A FE numerical simulation has been developed to analyse the dynamic thermo-mechanical effects. This has been verified against empirical data. The goal of the optimisation has been to develop a usable process window for the LF of AHSS within strict metallurgical constraints. Results indicate it is possible to LF this material, however a complex relationship has been found between the generation and maintenance of hardness values in the heated zone. A laser surface hardening effect has been observed that could be beneficial to the efficiency of the process.

  3. Diagnostic Role of ECG Recording Simultaneously With EEG Testing.

    PubMed

    Kendirli, Mustafa Tansel; Aparci, Mustafa; Kendirli, Nurten; Tekeli, Hakan; Karaoglan, Mustafa; Senol, Mehmet Guney; Togrol, Erdem

    2015-07-01

    Arrhythmia is not uncommon in the etiology of syncope which mimics epilepsy. Data about the epilepsy induced vagal tonus abnormalities have being increasingly reported. So we aimed to evaluate what a neurologist may gain by a simultaneous electrocardiogram (ECG) and electroencephalogram (EEG) recording in the patients who underwent EEG testing due to prediagnosis of epilepsy. We retrospectively evaluated and detected ECG abnormalities in 68 (18%) of 376 patients who underwent EEG testing. A minimum of 20 of minutes artifact-free recording were required for each patient. Standard 1-channel ECG was simultaneously recorded in conjunction with the EEG. In all, 28% of females and 14% of males had ECG abnormalities. Females (mean age 49 years, range 18-88 years) were older compared with the male group (mean age 28 years, range 16-83 years). Atrial fibrillation was more frequent in female group whereas bradycardia and respiratory sinus arrhythmia was higher in male group. One case had been detected a critical asystole indicating sick sinus syndrome in the female group and treated with a pacemaker implantation in the following period. Simultaneous ECG recording in conjunction with EEG testing is a clinical prerequisite to detect and to clarify the coexisting ECG and EEG abnormalities and their clinical relevance. Potentially rare lethal causes of syncope that mimic seizure or those that could cause resistance to antiepileptic therapy could effectively be distinguished by detecting ECG abnormalities coinciding with the signs and abnormalities during EEG recording.

  4. Flexible Graphene Electrodes for Prolonged Dynamic ECG Monitoring

    PubMed Central

    Lou, Cunguang; Li, Ruikai; Li, Zhaopeng; Liang, Tie; Wei, Zihui; Run, Mingtao; Yan, Xiaobing; Liu, Xiuling

    2016-01-01

    This paper describes the development of a graphene-based dry flexible electrocardiography (ECG) electrode and a portable wireless ECG measurement system. First, graphene films on polyethylene terephthalate (PET) substrates and graphene paper were used to construct the ECG electrode. Then, a graphene textile was synthesized for the fabrication of a wearable ECG monitoring system. The structure and the electrical properties of the graphene electrodes were evaluated using Raman spectroscopy, scanning electron microscopy (SEM), and alternating current impedance spectroscopy. ECG signals were then collected from healthy subjects using the developed graphene electrode and portable measurement system. The results show that the graphene electrode was able to acquire the typical characteristics and features of human ECG signals with a high signal-to-noise (SNR) ratio in different states of motion. A week-long continuous wearability test showed no degradation in the ECG signal quality over time. The graphene-based flexible electrode demonstrates comfortability, good biocompatibility, and high electrophysiological detection sensitivity. The graphene electrode also combines the potential for use in long-term wearable dynamic cardiac activity monitoring systems with convenience and comfort for use in home health care of elderly and high-risk adults. PMID:27809270

  5. Wireless Self-Acquistion of 12-Lead ECG via Android Smart Phone

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.

    2012-01-01

    -rested arms of the subject; 6) sufficient distal placement of the arm electrodes achieves good electrode abutment to the arms without the need for adhesives, straps, bands, bracelets, or gloves; 7) padding over the sternum avoids "tenting" in the V1 through V3 (and, when present, the V3R) electrode positions; 8) easy-to-don, one-piece design with an adjustable, front-side single point of connection and an adjustable shoulder strap; and 9) Lund or "modified Lund" placement of the dry electrodes, the results of which more effectively reproduce results from "standard" 12-lead ECG placements than do results from Mason-Likar placements. The main limitation of the harness is that "one size does not fit all", meaning that an appropriately sized harness (small, medium, large, etc) must be chosen on the basis of an individual's size. To facilitate the use of the harness with inexpensive, commodity-grade cell phones and tablet devices, 12-lead ECG software is also being developed to accompany the harness for wireless use with Android. For this part of the project, NASA has teamed with TopCoder, Inc and the Harvard-affiliated NASA Tournament Lab in sponsoring java-based software programming contests through TopCoder. While ECG signals from the harness can already be wirelessly received and thoroughly processed (locally or remotely) by commercial-grade conventional (as well as advanced) 12-lead ECG software running on Microsoft Windows(TM), the Android-based software, once completed, will "cast a wider net" by allowing for a greater percentage of cell phone owners to participate in inexpensive, store-and-forward recordings of 12-lead ECGs worldwide, including for example Android cell phone users in many remote, third-world locations. At the time of writing, the Android 12-lead ECG software platform consists of a basic but expanding graphical user interface and accompanying software that: 1) wirelessly receives the 12-lead ECG data stream from a Bluetooth-based, FDA-cleared 12-lea

  6. Advanced Electrocardiographic Predictors of Sudden Death in Familial Dysautonomia

    NASA Technical Reports Server (NTRS)

    Solaimanzadeh, I.; Schlegel, T. T.; Greco, E. C.; DePalma, J. L.; Starc, V.; Marthol, H.; Tutaj, M.; Buechner, S.; Axelrod, F. B.; Hilz, M. J.

    2007-01-01

    To identify accurate predictors for the risk of sudden death in patients with familial dysautonomia (FD). Ten-minute resting high-fidelity 12-lead ECGs were obtained from 14 FD patients and 14 age/gender-matched healthy subjects. Multiple conventional and advanced ECG parameters were studied for their ability to predict sudden death in FD over a subsequent 4.5-year period, including multiple indices of linear and non-linear heart rate variability (HRV); QT variability; waveform complexity; high frequency QRS; and derived Frank-lead parameters. Four of the 14 FD patients died suddenly during the follow-up period, usually with concomitant pulmonary disorder. The presence of low vagally-mediated HRV was the ECG finding most predictive of sudden death. Concomitant left ventricular hypertrophy and other ECG abnormalities such as increased QTc and JTc intervals, spatial QRS-T angles, T-wave complexity, and QT variability were also present in FD patients, suggesting that structural heart disease is fairly common in FD. Although excessive or unopposed cardiac vagal (relative to sympathetic) activity has been postulated as a contributor to sudden death in FD, the presence of low vagally-mediated HRV was paradoxically the best predictor of sudden death. However, we suggest that low vagally-mediated HRV be construed not as a direct cause of sudden death in FD, but rather as an effect of concurrent pathological processes, especially hypoxia due to pulmonary disorders and sleep apnea, that themselves increase the risk of sudden death in FD and simultaneously diminish HRV. We speculate that adenosine may play a role in sudden death in FD, possibly independently of vagal activity, and that adenosine inhibitors such as theophylline might therefore be useful as prophylaxis in this disorder.

  7. The 24-lead ECG display for enhanced recognition of STEMI-equivalent patterns in the 12-lead ECG.

    PubMed

    Pahlm, Ulrika; Pahlm, Olle; Wagner, Galen S

    2014-01-01

    In a patient with chest pain and suspected acute coronary syndrome, the electrocardiogram (ECG) is the only readily available diagnostic tool. It is important to maximize its usefulness to detect acute myocardial ischemia that may evolve to myocardial infarction unless the patient is treated expediently with reperfusion therapy. Since diagnostic guidelines have usually included only ST-elevation myocardial infarction (STEMI) as the entity that should be diagnosed and treated urgently, a patient with coronary occlusion represented on ECG as ST depression is likely not to be considered a candidate for receiving immediate coronary angiography and coronary intervention. ECG criteria for STEMI detection require that ST elevation meet predetermined millivolt thresholds and appear in at least two spatially contiguous ECG leads. The typical ECG reader recognizes only three contiguous pairs: aVL and I; II and aVF; aVF and III. However, viewing the "orderly sequenced" 12-lead ECG display, two more contiguous pairs become obvious in the frontal plane: +I and -aVR; -aVR and +II. The 24-lead ECG is a display of the standard 12-lead ECG as both the classical positive leads and their negative (inverted) counterparts. Leads +V1, +V2, +V3, +V4, +V5, and +V6 and their inverted counterparts are used to generate a "clock-face display" for the transverse plane. Similarly, +aVL, +I, -aVR, +II, +aVF, +III in the frontal plane and their inverted counterparts are used to generate a clock-face display for the frontal plane. Optimum results, 78% sensitivity and 93% specificity, were obtained using the following 19 ECG leads: frontal plane: +aVR, -III, +aVL, +I, -aVR, +II, +aVF, +III, -aVL; transverse plane: +V1, +V2, +V3, +V4, +V5, +V6, -V1, -V2, -V3.

  8. A Differential ECG Amplifier with Single-Ended Output

    NASA Technical Reports Server (NTRS)

    Katchis, L.

    1972-01-01

    Three-stage amplifier is used for ECG measurements which require conversion of differential input to single-ended output. Circuit may be useful in biological telemetry for amplification of signals from specimen-implanted sensors.

  9. Visualization of multivariate physiological data for cardiorespiratory fitness assessment through ECG (R-peak) analysis.

    PubMed

    Munoz, J E; Bermudez I Badia, S; Rubio, E; Cameirao, M S

    2015-01-01

    The recent rise and popularization of wearable and ubiquitous fitness sensors has increased our ability to generate large amounts of multivariate data for cardiorespiratory fitness (CRF) assessment. Consequently, there is a need to find new methods to visualize and interpret CRF data without overwhelming users. Current visualizations of CRF data are mainly tabular or in the form of stacked univariate plots. Moreover, normative data differs significantly between gender, age and activity, making data interpretation yet more challenging. Here we present a CRF assessment tool based on radar plots that provides a way to represent multivariate cardiorespiratory data from electrocardiographic (ECG) signals within its normative context. To that end, 5 parameters are extracted from raw ECG data using R-peak information: mean HR, SDNN, RMSSD, HRVI and the maximal oxygen uptake, VO2max. Our tool processes ECG data and produces a visualization of the data in a way that it is easy to compare between the performance of the user and normative data. This type of representation can assist both health professionals and non-expert users in the interpretation of CRF data.

  10. The ISCE ECG genome pilot challenge: a 2004 progress report.

    PubMed

    Kligfield, Paul; Badilini, Fabio; Brown, Barry; Helfenbein, Erich; Kohls, Mark

    2004-01-01

    The International Society for Computerized Electrocardiography (ISCE) "genome project" began in 2000 as an open-ended discussion of ECG database needs and opportunities. Cooperation within ISCE led to a "pilot challenge" of the database concept, which called for establishment of methodology for transmission, storage, and integrated re-analysis of digitized waveforms of three different ECG manufacturers. The present report documents the early implementation of that goal.

  11. Recent advances in computational predictions of NMR parameters for the structure elucidation of carbohydrates: methods and limitations.

    PubMed

    Toukach, Filip V; Ananikov, Valentine P

    2013-11-07

    All living systems are comprised of four fundamental classes of macromolecules--nucleic acids, proteins, lipids, and carbohydrates (glycans). Glycans play a unique role of joining three principal hierarchical levels of the living world: (1) the molecular level (pathogenic agents and vaccine recognition by the immune system, metabolic pathways involving saccharides that provide cells with energy, and energy accumulation via photosynthesis); (2) the nanoscale level (cell membrane mechanics, structural support of biomolecules, and the glycosylation of macromolecules); (3) the microscale and macroscale levels (polymeric materials, such as cellulose, starch, glycogen, and biomass). NMR spectroscopy is the most powerful research approach for getting insight into the solution structure and function of carbohydrates at all hierarchical levels, from monosaccharides to oligo- and polysaccharides. Recent progress in computational procedures has opened up novel opportunities to reveal the structural information available in the NMR spectra of saccharides and to advance our understanding of the corresponding biochemical processes. The ability to predict the molecular geometry and NMR parameters is crucial for the elucidation of carbohydrate structures. In the present paper, we review the major NMR spectrum simulation techniques with regard to chemical shifts, coupling constants, relaxation rates and nuclear Overhauser effect prediction applied to the three levels of glycomics. Outstanding development in the related fields of genomics and proteomics has clearly shown that it is the advancement of research tools (automated spectrum analysis, structure elucidation, synthesis, sequencing and amplification) that drives the large challenges in modern science. Combining NMR spectroscopy and the computational analysis of structural information encoded in the NMR spectra reveals a way to the automated elucidation of the structure of carbohydrates.

  12. Chest conduction properties and ECG equalization.

    PubMed

    Delle Cave, G; Fabricatore, G; Nolfe, G; Petrosino, M; Pizzuti, G P

    2000-01-01

    In common practice of detecting and recording biomedical signals, it is often implicitly assumed that the propagation, through the whole circuit human body-electrodes recording devices, is frequency and voltage independent. As a consequence, clinicians are not aware that recorded signals do not correspond faithfully to the original electrical activity of organs under investigation. We have studied the transmission of electrical signals in human body at various voltages and frequencies to understand if and to which extent the most diffused stimulating and recording techniques used in medicine are affected by global body conduction properties. Our results show that, in order to obtain a more faithful detection of electrical activity produced or evoked by human organs (e.g. EGG, electromyography, etc.), it is convenient to 'equalize'' recorded signals. To this purpose, two equalization techniques are proposed, based, respectively, on a simple hardware filtering during acquisition, or FFT post-processing of the acquired signals. As an application, we have studied the transmission of electrical signal in human chest and have compared equalized high frequency ECG signals with raw (original) recordings.

  13. Variability in surface ECG morphology: signal or noise?

    NASA Technical Reports Server (NTRS)

    Smith, J. M.; Rosenbaum, D. S.; Cohen, R. J.

    1988-01-01

    Using data collected from canine models of acute myocardial ischemia, we investigated two issues of major relevance to electrocardiographic signal averaging: ECG epoch alignment, and the spectral characteristics of the beat-to-beat variability in ECG morphology. With initial digitization rates of 1 kHz, an iterative a posteriori matched filtering alignment scheme, and linear interpolation, we demonstrated that there is sufficient information in the body surface ECG to merit alignment to a precision of 0.1 msecs. Applying this technique to align QRS complexes and atrial pacing artifacts independently, we demonstrated that the conduction delay from atrial stimulus to ventricular activation may be so variable as to preclude using atrial pacing as an alignment mechanism, and that this variability in conduction time be modulated at the frequency of respiration and at a much lower frequency (0.02-0.03Hz). Using a multidimensional spectral technique, we investigated the beat-to-beat variability in ECG morphology, demonstrating that the frequency spectrum of ECG morphological variation reveals a readily discernable modulation at the frequency of respiration. In addition, this technique detects a subtle beat-to-beat alternation in surface ECG morphology which accompanies transient coronary artery occlusion. We conclude that physiologically important information may be stored in the variability in the surface electrocardiogram, and that this information is lost by conventional averaging techniques.

  14. Unveiling the Biometric Potential of Finger-Based ECG Signals

    PubMed Central

    Lourenço, André; Silva, Hugo; Fred, Ana

    2011-01-01

    The ECG signal has been shown to contain relevant information for human identification. Even though results validate the potential of these signals, data acquisition methods and apparatus explored so far compromise user acceptability, requiring the acquisition of ECG at the chest. In this paper, we propose a finger-based ECG biometric system, that uses signals collected at the fingers, through a minimally intrusive 1-lead ECG setup recurring to Ag/AgCl electrodes without gel as interface with the skin. The collected signal is significantly more noisy than the ECG acquired at the chest, motivating the application of feature extraction and signal processing techniques to the problem. Time domain ECG signal processing is performed, which comprises the usual steps of filtering, peak detection, heartbeat waveform segmentation, and amplitude normalization, plus an additional step of time normalization. Through a simple minimum distance criterion between the test patterns and the enrollment database, results have revealed this to be a promising technique for biometric applications. PMID:21837235

  15. Optimal ECG Electrode Sites and Criteria for Detection of Asymptomatic Coronary Artery Disease - Update 1990. Multilead ECG Changes at Rest, with Exercise, and with Coronary Angioplasty

    DTIC Science & Technology

    1992-02-01

    AD-A248 613 OPTIMAL ECG ELECTRODE SITES AND CRITERIA CORONARY ARTERY DISEASE -UPDATE 1990 MULILEAD ECG CHANGES AT REST, WITH A EXERCISE, AND WITH...5. FUNDING NUMBERS Optimal ECG Electrode Sites and Criteria for Detection of Asymptomatic C - F33615-87-D-0609/0023 Coronary Artery Disease --Update...improve the detection of asymptomatic coronary disease . Three ECG recording systems with signal processing of 30 simultaneous leads (30SL) have been

  16. Standard-compliant real-time transmission of ECGs: harmonization of ISO/IEEE 11073-PHD and SCP-ECG.

    PubMed

    Trigo, Jesús D; Chiarugi, Franco; Alesanco, Alvaro; Martínez-Espronceda, Miguel; Chronaki, Catherine E; Escayola, Javier; Martínez, Ignacio; García, José

    2009-01-01

    Ambient assisted living and integrated care in an aging society is based on the vision of the lifelong Electronic Health Record calling for HealthCare Information Systems and medical device interoperability. For medical devices this aim can be achieved by the consistent implementation of harmonized international interoperability standards. The ISO/IEEE 11073 (x73) family of standards is a reference standard for medical device interoperability. In its Personal Health Device (PHD) version several devices have been included, but an ECG device specialization is not yet available. On the other hand, the SCP-ECG standard for short-term diagnostic ECGs (EN1064) has been recently approved as an international standard ISO/IEEE 11073-91064:2009. In this paper, the relationships between a proposed x73-PHD model for an ECG device and the fields of the SCP-ECG standard are investigated. A proof-of-concept implementation of the proposed x73-PHD ECG model is also presented, identifying open issues to be addressed by standards development for the wider interoperability adoption of x73-PHD standards.

  17. Countermeasures (iRED, ARED CEVIS, MEC, TVIS, T2, Periodic Fitness Evaluation, BP-ECG, HRM). Critical Readiness Review Increment 23 and 24

    NASA Technical Reports Server (NTRS)

    Toder, Carly; Gipson, Iona; Conly, Danielle; Nieschwitz, Linda; Perk, Austin

    2010-01-01

    This slide presentation reviews attempts to counteract the effects of being in space. It includes information on the Resistive Exercise Device (RED), the Advanced Resistive Exercise Device (ARED), Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS), Treadmill with Vibration Isolation and Stabilization (TVIS) and periodic fitness evaluation with specific information on BP/ECG, heart rate monitor 2 and data distribution.

  18. An adaptive Kalman filter for ECG signal enhancement.

    PubMed

    Vullings, Rik; de Vries, Bert; Bergmans, Jan W M

    2011-04-01

    The ongoing trend of ECG monitoring techniques to become more ambulatory and less obtrusive generally comes at the expense of decreased signal quality. To enhance this quality, consecutive ECG complexes can be averaged triggered on the heartbeat, exploiting the quasi-periodicity of the ECG. However, this averaging constitutes a tradeoff between improvement of the SNR and loss of clinically relevant physiological signal dynamics. Using a bayesian framework, in this paper, a sequential averaging filter is developed that, in essence, adaptively varies the number of complexes included in the averaging based on the characteristics of the ECG signal. The filter has the form of an adaptive Kalman filter. The adaptive estimation of the process and measurement noise covariances is performed by maximizing the bayesian evidence function of the sequential ECG estimation and by exploiting the spatial correlation between several simultaneously recorded ECG signals, respectively. The noise covariance estimates thus obtained render the filter capable of ascribing more weight to newly arriving data when these data contain morphological variability, and of reducing this weight in cases of no morphological variability. The filter is evaluated by applying it to a variety of ECG signals. To gauge the relevance of the adaptive noise-covariance estimation, the performance of the filter is compared to that of a Kalman filter with fixed, (a posteriori) optimized noise covariance. This comparison demonstrates that, without using a priori knowledge on signal characteristics, the filter with adaptive noise estimation performs similar to the filter with optimized fixed noise covariance, favoring the adaptive filter in cases where no a priori information is available or where signal characteristics are expected to fluctuate.

  19. The prevalence of abnormal ECG in trained sportsmen

    PubMed Central

    Malhotra, V.K.; Singh, Navreet; Bishnoi, R.S.; Chadha, D.S.; Bhardwaj, P.; Madan, H.; Dutta, R.; Ghosh, A.K.; Sengupta, S.; Perumal, P.

    2015-01-01

    Background Competitive sports training causes structural and conductive system changes manifesting by various electrocardiographic alterations. We undertook this study to assess the prevalence of abnormal ECG in trained Indian athletes and correlate it with the nature of sports training, that is endurance or strength training. Methods We evaluated a standard resting, lying 12 lead Electrocardiogram (ECG) in 66 actively training Indian athletes. Standard diagnostic criteria were used to define various morphological ECG abnormalities. Results 33/66 (50%) of the athletes were undertaking endurance training while the other 33 (50%) were involved in a strength-training regimen. Overall 54/66 (81%) sportsmen had significant ECG changes. 68% of these changes were considered as normal training related features, while the remaining 32% were considered abnormal. There were seven common training related ECG changes–Sinus Bradycardia (21%), Sinus Arrhythmia (16%), 1st degree Atrioventricular Heart Block (6%), Type 1 2nd-degree Atrioventicular Heart Block (3%), Incomplete Right bundle branch block (RBBB) (24%), Early Repolarization (42%), Left Ventricular Hypertrophy (LVH) (14%); while three abnormal ECG changes--T-wave inversion (13%), RBBB(4%), Right ventricular hypertrophy (RVH) with strain (29%) were noted. Early repolarization (commonest change), sinus bradycardia, and incomplete RBBB were the commoner features noticed, with a significantly higher presence in the endurance trained athletes. Conclusion A high proportion of athletes undergoing competitive level sports training are likely to have abnormal ECG recordings. Majority of these are benign, and related to the physiological adaptation to the extreme levels of exertion. These changes are commoner during endurance training (running) than strength training (weightlifting). PMID:26663958

  20. ECG derived respiration: comparison of time-domain approaches and application to altered breathing patterns of patients with schizophrenia.

    PubMed

    Schmidt, Marcus; Schumann, Andy; Müller, Jonas; Bär, Karl-Jürgen; Rose, Georg

    2017-04-01

    In life-threatening diseases and in several clinical interventions, monitoring of vital parameters is essential to guarantee the safety of patients. Besides monitoring the electrocardiogram (ECG), it is helpful to assess respiratory activity. If the respiration signal itself is not recorded, it can be extracted from the ECG (i.e. ECG derived respiration, EDR). In the present paper, we compared six EDR approaches, namely RS-decline quantified by central moments, respiratory sinus arrhythmia (RSA), R-wave amplitude, QRS area, RS-distance and maximum RS-slope. In order to evaluate the performance of each approach, we applied each method to a database of ECGs and reference respiration signals of 41 healthy subjects. All considered methods revealed relatively small absolute mean errors of the breathing rate (BR) at rest (0.75-1.3 Bpm). The method based on higher order central moments revealed a minimum mean absolute error of 0.75 Bpm (4.40%) and a maximum correlation and concordance with the reference BR (r p  =  0.97, r c  =  0.97). Using this technique, we analyzed changes of respiration in patients suffering from acute schizophrenia. An increased respiration rate of about 4 Bpm was found. Additionally, alteration of respiratory ratio and reduced respiratory sinus arrhythmia was demonstrated. We conclude that a precise dynamic monitoring of breathing and the investigation of changes in breathing patterns is possible without recording respiration per se.

  1. A mobile phone-based ECG monitoring system.

    PubMed

    Iwamoto, Junichi; Yonezawa, Yoshiharu; Maki, Hiromichi; Ogawa, Hidekuni; Ninomiya, Ishio; Sada, Kouji; Hamada, Shingo; Hahn, Allen W; Caldwell, W Morton

    2006-01-01

    We have developed a telemedicine system for monitoring a patient's electrocardiogram during daily activities. The recording system consists of three ECG chest electrodes, a variable gain instrumentation amplifier, a low power 8-bit single-chip microcomputer, a 256 KB EEPROM and a 2.4 GHz low transmitting power mobile phone (PHS). The complete system is mounted on a single, lightweight, chest electrode array. When a heart discomfort is felt, the patient pushes the data transmission switch on the recording system. The system sends the recorded ECG waveforms of the two prior minutes and ECG waveforms of the two minutes after the switch is pressed, directly in the hospital server computer via the PHS. The server computer sends the data to the physician on call. The data is displayed on the doctor's Java mobile phone LCD (Liquid Crystal Display), so he or she can monitor the ECG regardless of their location. The developed ECG monitoring system is not only applicable to at-home patients, but should also be useful for monitoring hospital patients.

  2. A controlled study of a new ECG electrode system.

    PubMed

    Sheffield, L T; Roitman, D I; Kansal, S

    1978-07-01

    A newly marketed resting ECG electrode system was compared with conventional metal suction and plate electrodes, electrode cream and patient cable. Two experienced technicians were given special training in the use of the new electrode, electrolyte and patient cable system and alternated daily in using new and conventional equipment. Nearly equal numbers of perfect-scoring ECGs were recorded with each system, attesting to the impartiality of the technicians. A total of 1,062 ECGs were evaluated, 554 with the new system and 508 with the conventional one. ECG tracings were evaluated by electrocardiographers unaware of which system was used for each. A quantitative scoring system was used to measure the technical quality of each tracing in terms of baseline drift, powerline artifact and myographic plus miscellaneous artifacts. The new system received mean scores of 2.33, 3.08, and 2.72, respectively, while the conventional electrodes received scores of 2.56, 3.03 and 2.79. We concluded that the two types of electrodes produced ECGs of essentially equal quality.

  3. Fast multi-scale feature fusion for ECG heartbeat classification

    NASA Astrophysics Data System (ADS)

    Ai, Danni; Yang, Jian; Wang, Zeyu; Fan, Jingfan; Ai, Changbin; Wang, Yongtian

    2015-12-01

    Electrocardiogram (ECG) is conducted to monitor the electrical activity of the heart by presenting small amplitude and duration signals; as a result, hidden information present in ECG data is difficult to determine. However, this concealed information can be used to detect abnormalities. In our study, a fast feature-fusion method of ECG heartbeat classification based on multi-linear subspace learning is proposed. The method consists of four stages. First, baseline and high frequencies are removed to segment heartbeat. Second, as an extension of wavelets, wavelet-packet decomposition is conducted to extract features. With wavelet-packet decomposition, good time and frequency resolutions can be provided simultaneously. Third, decomposed confidences are arranged as a two-way tensor, in which feature fusion is directly implemented with generalized N dimensional ICA (GND-ICA). In this method, co-relationship among different data information is considered, and disadvantages of dimensionality are prevented; this method can also be used to reduce computing compared with linear subspace-learning methods (PCA). Finally, support vector machine (SVM) is considered as a classifier in heartbeat classification. In this study, ECG records are obtained from the MIT-BIT arrhythmia database. Four main heartbeat classes are used to examine the proposed algorithm. Based on the results of five measurements, sensitivity, positive predictivity, accuracy, average accuracy, and t-test, our conclusion is that a GND-ICA-based strategy can be used to provide enhanced ECG heartbeat classification. Furthermore, large redundant features are eliminated, and classification time is reduced.

  4. Shannon's Energy Based Algorithm in ECG Signal Processing.

    PubMed

    Beyramienanlou, Hamed; Lotfivand, Nasser

    2017-01-01

    Physikalisch-Technische Bundesanstalt (PTB) database is electrocardiograms (ECGs) set from healthy volunteers and patients with different heart diseases. PTB is provided for research and teaching purposes by National Metrology Institute of Germany. The analysis method of complex QRS in ECG signals for diagnosis of heart disease is extremely important. In this article, a method on Shannon energy (SE) in order to detect QRS complex in 12 leads of ECG signal is provided. At first, this algorithm computes the Shannon energy (SE) and then makes an envelope of Shannon energy (SE) by using the defined threshold. Then, the signal peaks are determined. The efficiency of the algorithm is tested on 70 cases. Of all 12 standard leads, ECG signals include 840 leads of the PTB Diagnostic ECG Database (PTBDB). The algorithm shows that the Shannon energy (SE) sensitivity is equal to 99.924%, the detection error rate (DER) is equal to 0.155%, Positive Predictivity (+P) is equal to 99.922%, and Classification Accuracy (Acc) is equal to 99.846%.

  5. Exploiting prior knowledge in compressed sensing wireless ECG systems.

    PubMed

    Polanía, Luisa F; Carrillo, Rafael E; Blanco-Velasco, Manuel; Barner, Kenneth E

    2015-03-01

    Recent results in telecardiology show that compressed sensing (CS) is a promising tool to lower energy consumption in wireless body area networks for electrocardiogram (ECG) monitoring. However, the performance of current CS-based algorithms, in terms of compression rate and reconstruction quality of the ECG, still falls short of the performance attained by state-of-the-art wavelet-based algorithms. In this paper, we propose to exploit the structure of the wavelet representation of the ECG signal to boost the performance of CS-based methods for compression and reconstruction of ECG signals. More precisely, we incorporate prior information about the wavelet dependencies across scales into the reconstruction algorithms and exploit the high fraction of common support of the wavelet coefficients of consecutive ECG segments. Experimental results utilizing the MIT-BIH Arrhythmia Database show that significant performance gains, in terms of compression rate and reconstruction quality, can be obtained by the proposed algorithms compared to current CS-based methods.

  6. Shannon's Energy Based Algorithm in ECG Signal Processing

    PubMed Central

    2017-01-01

    Physikalisch-Technische Bundesanstalt (PTB) database is electrocardiograms (ECGs) set from healthy volunteers and patients with different heart diseases. PTB is provided for research and teaching purposes by National Metrology Institute of Germany. The analysis method of complex QRS in ECG signals for diagnosis of heart disease is extremely important. In this article, a method on Shannon energy (SE) in order to detect QRS complex in 12 leads of ECG signal is provided. At first, this algorithm computes the Shannon energy (SE) and then makes an envelope of Shannon energy (SE) by using the defined threshold. Then, the signal peaks are determined. The efficiency of the algorithm is tested on 70 cases. Of all 12 standard leads, ECG signals include 840 leads of the PTB Diagnostic ECG Database (PTBDB). The algorithm shows that the Shannon energy (SE) sensitivity is equal to 99.924%, the detection error rate (DER) is equal to 0.155%, Positive Predictivity (+P) is equal to 99.922%, and Classification Accuracy (Acc) is equal to 99.846%. PMID:28197213

  7. Acute “Pseudoischemic” ECG Abnormalities after Right Pneumonectomy

    PubMed Central

    Dimic-Janjic, Sanja; Stevic, Ruza; Milenkovic, Branislava; Djukanovic, Verica

    2017-01-01

    New onset of electrocardiographic (ECG) abnormalities can occur after lung surgery due to the changes in the position of structures and organs in the chest cavity. The most common heart rhythm disorder is atrial fibrillation. So-called “pseudoischemic” ECG changes that mimic classic ECG signs of acute myocardial ischemia are also often noticed. We report the case of a 68-year-old male, with no prior cardiovascular disease, who underwent extensive surgical resection for lung cancer. On a second postoperative day, clinical and electrocardiographic signs of acute myocardial ischemia occurred. According to clinical course, diagnostic procedures, and therapeutic response, we excluded acute coronary syndrome. We concluded that physical lesion of the pericardium, caused by extended pneumonectomy with resection of the pericardium, provoked the symptoms and ECG signs that mimic acute coronary syndrome. Our final diagnosis was postpericardiotomy syndrome after extended pneumonectomy and further treatment with nonsteroidal anti-inflammatory drugs (NSAIDs) was recommended. It is necessary to consider possibility that nature of ECG changes after extended pneumonectomy could be “pseudoischemic.” PMID:28197356

  8. A system for intelligent home care ECG upload and priorisation.

    PubMed

    D'Angelo, Lorenzo T; Tarita, Eugeniu; Zywietz, Tosja K; Lueth, Tim C

    2010-01-01

    In this contribution, a system for internet based, automated home care ECG upload and priorisation is presented for the first time. It unifies the advantages of existing telemonitoring ECG systems adding functionalities such as automated priorisation and usability for home care. Chronic cardiac diseases are a big group in the geriatric field. Most of them can be easily diagnosed with help of an electrocardiogram. A frequent or long-term ECG analysis allows early diagnosis of e.g. a cardiac infarction. Nevertheless, patients often aren't willing to visit a doctor for prophylactic purposes. Possible solutions of this problem are home care devices, which are used to investigate patients at home without the presence of a doctor on site. As the diffusion of such systems leads to a huge amount of data which has to be managed and evaluated, the presented approach focuses on an easy to use software for ECG upload from home, a web based management application and an algorithm for ECG preanalysis and priorisation.

  9. PIC microcontroller-based RF wireless ECG monitoring system.

    PubMed

    Oweis, R J; Barhoum, A

    2007-01-01

    This paper presents a radio-telemetry system that provides the possibility of ECG signal transmission from a patient detection circuit via an RF data link. A PC then receives the signal through the National Instrument data acquisition card (NIDAQ). The PC is equipped with software allowing the received ECG signals to be saved, analysed, and sent by email to another part of the world. The proposed telemetry system consists of a patient unit and a PC unit. The amplified and filtered ECG signal is sampled 360 times per second, and the A/D conversion is performed by a PIC16f877 microcontroller. The major contribution of the final proposed system is that it detects, processes and sends patients ECG data over a wireless RF link to a maximum distance of 200 m. Transmitted ECG data with different numbers of samples were received, decoded by means of another PIC microcontroller, and displayed using MATLAB program. The designed software is presented in a graphical user interface utility.

  10. A new mobile phone-based ECG monitoring system.

    PubMed

    Iwamoto, Junichi; Yonezawa, Yoshiharu; Ogawa, Hiromichi Maki Hidekuni; Ninomiya, Ishio; Sada, Kouji; Hamada, Shingo; Hahn, Allen W; Caldwell, W Morton

    2007-01-01

    We have developed a system for monitoring a patient's electrocardiogram (ECG) and movement during daily activities. The complete system is mounted on chest electrodes and continuously samples the ECG and three axis accelerations. When the patient feels a heart discomfort, he or she pushes the data transmission switch on the recording system and the system sends the recorded ECG waveforms and three axis accelerations of the two prior minutes, and for two minutes after the switch is pressed. The data goes directly to a hospital server computer via a 2.4 GHz low power mobile phone. These data are stored on a server computer and downloaded to the physician's Java mobile phone. The physician can display the data on the phone's liquid crystal display.

  11. Chaos control applied to cardiac rhythms represented by ECG signals

    NASA Astrophysics Data System (ADS)

    Borem Ferreira, Bianca; Amorim Savi, Marcelo; Souza de Paula, Aline

    2014-10-01

    The control of irregular or chaotic heartbeats is a key issue in cardiology. In this regard, chaos control techniques represent a good alternative since they suggest treatments different from those traditionally used. This paper deals with the application of the extended time-delayed feedback control method to stabilize pathological chaotic heart rhythms. Electrocardiogram (ECG) signals are employed to represent the cardiovascular behavior. A mathematical model is employed to generate ECG signals using three modified Van der Pol oscillators connected with time delay couplings. This model provides results that qualitatively capture the general behavior of the heart. Controlled ECG signals show the ability of the strategy either to control or to suppress the chaotic heart dynamics generating less-critical behaviors.

  12. ECG Holter monitor with alert system and mobile application

    NASA Astrophysics Data System (ADS)

    Teron, Abigail C.; Rivera, Pedro A.; Goenaga, Miguel A.

    2016-05-01

    This paper proposes a new approach on the Holter monitor by creating a portable Electrocardiogram (ECG) Holter monitor that will alert the user by detecting abnormal heart beats using a digital signal processing software. The alarm will be triggered when the patient experiences arrhythmias such as bradycardia and tachycardia. The equipment is simple, comfortable and small in size that fit in the hand. It can be used at any time and any moment by placing three leads to the person's chest which is connected to an electronic circuit. The ECG data will be transmitted via Bluetooth to the memory of a selected mobile phone using an application that will store the collected data for up to 24 hrs. The arrhythmia is identified by comparing the reference signals with the user's signal. The diagnostic results demonstrate that the ECG Holter monitor alerts the user when an arrhythmia is detected thru the Holter monitor and mobile application.

  13. Convolutional Neural Networks for patient-specific ECG classification.

    PubMed

    Kiranyaz, Serkan; Ince, Turker; Hamila, Ridha; Gabbouj, Moncef

    2015-01-01

    We propose a fast and accurate patient-specific electrocardiogram (ECG) classification and monitoring system using an adaptive implementation of 1D Convolutional Neural Networks (CNNs) that can fuse feature extraction and classification into a unified learner. In this way, a dedicated CNN will be trained for each patient by using relatively small common and patient-specific training data and thus it can also be used to classify long ECG records such as Holter registers in a fast and accurate manner. Alternatively, such a solution can conveniently be used for real-time ECG monitoring and early alert system on a light-weight wearable device. The experimental results demonstrate that the proposed system achieves a superior classification performance for the detection of ventricular ectopic beats (VEB) and supraventricular ectopic beats (SVEB).

  14. Non-contact ECG sensing employing gradiometer electrodes.

    PubMed

    Peng, GuoChen; Bocko, Mark F

    2013-01-01

    Noncontact, capacitive electrocardiogram (ECG) measurements are complicated by motion artifacts from the relative movement between the ECG electrodes and the subject. To compensate for such motion we propose to employ first and second order gradiometer electrode designs. A MATLAB-based simulation tool to enable assessment of different electrode configurations and placements on human subjects has been developed to guide the refinement of electrode designs. Experimental measurements of the sensitivity, motion artifact cancellation, and common mode rejection for various prototype designs were conducted with human subjects. Second order gradiometer electrode designs appear to give the best performance as measured by signal to noise plus distortion ratio. Finally, both gradiometer designs were compared with standard ECG recording methods and showed less than 1% beat detection mismatch employing an open source beat detection algorithm.

  15. ECG Interpretation Using the CRISP Method: A Guide for Nurses.

    PubMed

    Atwood, Denise; Wadlund, Diana L

    2015-10-01

    Nurses often struggle with identifying electrocardiogram (ECG) rhythms, but rapidly interpreting these rhythms is an essential skill that every nurse should master, especially in the perioperative setting. The CRISP (Cardiac Rhythm Identification for Simple People) method is an algorithm designed to help nurses rapidly interpret ECGs. Key aspects of assisting patients with suspected cardiac issues include the nursing assessment, correct three-lead ECG placement, and calculation of the heart rate. Then the perioperative nurse can use the steps of the CRISP method to identify nursing actions related to specific arrhythmias, including determining whether QRS complexes are present, P waves are present, and QRS complexes are wide or narrow or whether there are more P waves than QRS complexes.

  16. Design intelligent wheelchair with ECG measurement and wireless transmission function.

    PubMed

    Chou, Hsi-Chiang; Wang, Yi-Ming; Chang, Huai-Yuan

    2015-01-01

    The phenomenon of aging populations has produced widespread health awareness and magnified the need for improved medical quality and technologies. Statistics show that ischemic heart disease is the leading cause of death for older people and people with reduced mobility; therefore, wheelchairs have become their primary means of transport. Hence, an arrhythmia-detecting smart wheelchair was proposed in this study to provide real-time electrocardiography (ECG)-monitoring to patients with heart disease and reduced mobility. A self-developed, handheld ECG-sensing instrument was integrated with a wheelchair and a lab-written, arrhythmia-detecting program. The measured ECG data were transmitted through a Wi-Fi module and analyzed and diagnosed using the human-machine interface.

  17. The ECG vertigo in diabetes and cardiac autonomic neuropathy.

    PubMed

    Voulgari, Christina; Tentolouris, Nicholas; Stefanadis, Christodoulos

    2011-01-01

    The importance of diabetes in the epidemiology of cardiovascular diseases cannot be overemphasized. About one third of acute myocardial infarction patients have diabetes, and its prevalence is steadily increasing. The decrease in cardiac mortality in people with diabetes is lagging behind that of the general population. Cardiovascular disease is a broad term which includes any condition causing pathological changes in blood vessels, cardiac muscle or valves, and cardiac rhythm. The ECG offers a quick, noninvasive clinical and research screen for the early detection of cardiovascular disease in diabetes. In this paper, the clinical and research value of the ECG is readdressed in diabetes and in the presence of cardiac autonomic neuropathy.

  18. Noninvasive fetal ECG estimation using adaptive comb filter.

    PubMed

    Wei, Zheng; Xueyun, Wei; Jian jian, Zhong; Hongxing, Liu

    2013-10-01

    This paper describes a robust and simple algorithm for fetal electrocardiogram (FECG) estimation from abdominal signal using adaptive comb filter (ACF). The ACF can adjust itself to the temporal variations in fundamental frequency, which makes it qualified for the estimation of quasi-periodic component from physiologic signal, such as ECG. The validity and performance of the described method are confirmed through experiments on real fetal ECG data. A comparison with the well-known independent component analysis (ICA) method has also been presented.

  19. A World Wide Web accessible multi-species ECG database.

    PubMed

    Hammann, H P; Suedmeyer, W K; Hahn, A W

    1997-01-01

    We have developed a system for remotely accessible secure electronic storage of electrocardiographic (ECG) and other associated data. It allows entry of data from any authorized remote user and is specifically built to accommodate the ECGs of multiple species. The present system is implemented on a Sun Sparc Solaris 2.5 platform using Oracle 7.3.2, and the Oracle 7.3.2 Web server. It may be easily ported to any other UNIX or Windows NT platform. No client is needed other than an Internet Protocol connected computer using a web browser such as Netscape Navigator or Microsoft Internet Explorer.

  20. A Novel Automatic Detection System for ECG Arrhythmias Using Maximum Margin Clustering with Immune Evolutionary Algorithm

    PubMed Central

    Zhu, Bohui; Ding, Yongsheng; Hao, Kuangrong

    2013-01-01

    This paper presents a novel maximum margin clustering method with immune evolution (IEMMC) for automatic diagnosis of electrocardiogram (ECG) arrhythmias. This diagnostic system consists of signal processing, feature extraction, and the IEMMC algorithm for clustering of ECG arrhythmias. First, raw ECG signal is processed by an adaptive ECG filter based on wavelet transforms, and waveform of the ECG signal is detected; then, features are extracted from ECG signal to cluster different types of arrhythmias by the IEMMC algorithm. Three types of performance evaluation indicators are used to assess the effect of the IEMMC method for ECG arrhythmias, such as sensitivity, specificity, and accuracy. Compared with K-means and iterSVR algorithms, the IEMMC algorithm reflects better performance not only in clustering result but also in terms of global search ability and convergence ability, which proves its effectiveness for the detection of ECG arrhythmias. PMID:23690875

  1. ECG Identification System Using Neural Network with Global and Local Features

    ERIC Educational Resources Information Center

    Tseng, Kuo-Kun; Lee, Dachao; Chen, Charles

    2016-01-01

    This paper proposes a human identification system via extracted electrocardiogram (ECG) signals. Two hierarchical classification structures based on global shape feature and local statistical feature is used to extract ECG signals. Global shape feature represents the outline information of ECG signals and local statistical feature extracts the…

  2. Robust and Accurate Anomaly Detection in ECG Artifacts Using Time Series Motif Discovery

    PubMed Central

    Sivaraks, Haemwaan

    2015-01-01

    Electrocardiogram (ECG) anomaly detection is an important technique for detecting dissimilar heartbeats which helps identify abnormal ECGs before the diagnosis process. Currently available ECG anomaly detection methods, ranging from academic research to commercial ECG machines, still suffer from a high false alarm rate because these methods are not able to differentiate ECG artifacts from real ECG signal, especially, in ECG artifacts that are similar to ECG signals in terms of shape and/or frequency. The problem leads to high vigilance for physicians and misinterpretation risk for nonspecialists. Therefore, this work proposes a novel anomaly detection technique that is highly robust and accurate in the presence of ECG artifacts which can effectively reduce the false alarm rate. Expert knowledge from cardiologists and motif discovery technique is utilized in our design. In addition, every step of the algorithm conforms to the interpretation of cardiologists. Our method can be utilized to both single-lead ECGs and multilead ECGs. Our experiment results on real ECG datasets are interpreted and evaluated by cardiologists. Our proposed algorithm can mostly achieve 100% of accuracy on detection (AoD), sensitivity, specificity, and positive predictive value with 0% false alarm rate. The results demonstrate that our proposed method is highly accurate and robust to artifacts, compared with competitive anomaly detection methods. PMID:25688284

  3. Robust and accurate anomaly detection in ECG artifacts using time series motif discovery.

    PubMed

    Sivaraks, Haemwaan; Ratanamahatana, Chotirat Ann

    2015-01-01

    Electrocardiogram (ECG) anomaly detection is an important technique for detecting dissimilar heartbeats which helps identify abnormal ECGs before the diagnosis process. Currently available ECG anomaly detection methods, ranging from academic research to commercial ECG machines, still suffer from a high false alarm rate because these methods are not able to differentiate ECG artifacts from real ECG signal, especially, in ECG artifacts that are similar to ECG signals in terms of shape and/or frequency. The problem leads to high vigilance for physicians and misinterpretation risk for nonspecialists. Therefore, this work proposes a novel anomaly detection technique that is highly robust and accurate in the presence of ECG artifacts which can effectively reduce the false alarm rate. Expert knowledge from cardiologists and motif discovery technique is utilized in our design. In addition, every step of the algorithm conforms to the interpretation of cardiologists. Our method can be utilized to both single-lead ECGs and multilead ECGs. Our experiment results on real ECG datasets are interpreted and evaluated by cardiologists. Our proposed algorithm can mostly achieve 100% of accuracy on detection (AoD), sensitivity, specificity, and positive predictive value with 0% false alarm rate. The results demonstrate that our proposed method is highly accurate and robust to artifacts, compared with competitive anomaly detection methods.

  4. Accurate Interpretation of the 12-Lead ECG Electrode Placement: A Systematic Review

    ERIC Educational Resources Information Center

    Khunti, Kirti

    2014-01-01

    Background: Coronary heart disease (CHD) patients require monitoring through ECGs; the 12-lead electrocardiogram (ECG) is considered to be the non-invasive gold standard. Examples of incorrect treatment because of inaccurate or poor ECG monitoring techniques have been reported in the literature. The findings that only 50% of nurses and less than…

  5. ECG Monitoring in Cardiac Rehabilitation: Is It Needed?

    ERIC Educational Resources Information Center

    Greenland, Philip; Pomilla, Paul V.

    1989-01-01

    Discusses the controversial use of continuous electrocardiogram (ECG) monitoring as a safety measure in cardiac rehabilitation exercise programs. Little evidence substantiates its value for all patients during exercise. In the absence of empirical evidence documenting the worth of this expensive procedure, it is recommended for use with high-risk…

  6. 21 CFR 892.1970 - Radiographic ECG/respirator synchronizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Radiographic ECG/respirator synchronizer. 892.1970 Section 892.1970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1970 Radiographic...

  7. 21 CFR 892.1970 - Radiographic ECG/respirator synchronizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Radiographic ECG/respirator synchronizer. 892.1970 Section 892.1970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1970 Radiographic...

  8. 21 CFR 892.1970 - Radiographic ECG/respirator synchronizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Radiographic ECG/respirator synchronizer. 892.1970 Section 892.1970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1970 Radiographic...

  9. 21 CFR 892.1970 - Radiographic ECG/respirator synchronizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Radiographic ECG/respirator synchronizer. 892.1970 Section 892.1970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1970 Radiographic...

  10. Cardiac Electrophysiology: Normal and Ischemic Ionic Currents and the ECG

    ERIC Educational Resources Information Center

    Klabunde, Richard E.

    2017-01-01

    Basic cardiac electrophysiology is foundational to understanding normal cardiac function in terms of rate and rhythm and initiation of cardiac muscle contraction. The primary clinical tool for assessing cardiac electrical events is the electrocardiogram (ECG), which provides global and regional information on rate, rhythm, and electrical…

  11. ECG gated NMR-CT for cardiovascular diseases

    SciTech Connect

    Nishikawa, J.; Ohtake, T.; Machida, K.; Iio, M.; Yoshimoto, N.; Sugimoto, T.

    1985-05-01

    The authors have been applying ECG gated NMR-CT to mainly patients with myocardial infarction (MI), and hypertrophic cardiomyopathy (HCM). Thirteen patients with MI, 8 with HCM and 5 without any heart diseases were studied by ECG gated NMR imaging (spin-echo technique, TR: depends on patient heart rate, TE: 35 and 70 msec.) with 0.35 T superconducting magnet. On NMR images (MRI), the authors examined the wall thickness, wall motion and T/sub 2/ relaxation time in the area of diseased myocardium. The lesions of old MI were depicted as the area of thin wall and T/sub 2/ relaxation time of those lesions were similar to the area of non-infarcted myocardium. The lesions of recent MI (up to 3.5 months from the recent attack) were shown as the same wall thickness as the non-infarcted myocardium and the area of prolonged T/sub 2/ relaxation time compared with that of non-infarcted myocardium. MRI demonstrated diffusely thick myocardium in all patients with HCM. T/sub 2/ relaxation time of the areas of HCM was almost the same as that of normal myocardium, and it's difference among each ventricular wall in patients with HCM was not statistically significant. The authors conclude that ECG gated NMR-CT offers 3-D morphological information of the heart without any contrast material nor radioisotopes. ECG gated MRI provides the useful informations to diagnose MI, especially in the differential diagnosis between old and recent MI.

  12. Noninvasive ECG as a tool for predicting termination of paroxysmal atrial fibrillation.

    PubMed

    Chiarugi, Franco; Varanini, Maurizio; Cantini, Federico; Conforti, Fabrizio; Vrouchos, Giorgos

    2007-08-01

    Atrial fibrillation (AF) is the most common cardiac arrhythmia and entails an increased risk of thromboembolic events. Prediction of the termination of an AF episode, based on noninvasive techniques, can benefit patients, doctors and health systems. The method described in this paper is based on two-lead surface electrocardiograms (ECGs): 1-min ECG recordings of AF episodes including N-type (not terminating within an hour after the end of the record), S-type (terminating 1 min after the end of the record) and T-type (terminating immediately after the end of the record). These records are organised into three learning sets (N, S and T) and two test sets (A and B). Starting from these ECGs, the atrial and ventricular activities were separated using beat classification and class averaged beat subtraction, followed by the evaluation of seven parameters representing atrial or ventricular activity. Stepwise discriminant analysis selected the set including dominant atrial frequency (DAF, index of atrial activity) and average HR (HRmean, index of ventricular activity) as optimal for discrimination between N/T-type episodes. The linear classifier, estimated on the 20 cases of the N and T learning sets, provided a performance of 90% on the 30 cases of a test set for the N/T-type discrimination. The same classifier led to correct classification in 89% of the 46 cases for N/S-type discrimination. The method has shown good results and seems to be suitable for clinical application, although a larger dataset would be very useful for improvement and validation of the algorithms and the development of an earlier predictor of paroxysmal AF spontaneous termination time.

  13. Water-Exchange-Modified Kinetic Parameters from Dynamic Contrast-Enhanced MRI as Prognostic Biomarkers of Survival in Advanced Hepatocellular Carcinoma Treated with Antiangiogenic Monotherapy

    PubMed Central

    Lee, Sang Ho; Hayano, Koichi; Zhu, Andrew X.; Sahani, Dushyant V.; Yoshida, Hiroyuki

    2015-01-01

    Background To find prognostic biomarkers in pretreatment dynamic contrast-enhanced MRI (DCE-MRI) water-exchange-modified (WX) kinetic parameters for advanced hepatocellular carcinoma (HCC) treated with antiangiogenic monotherapy. Methods Twenty patients with advanced HCC underwent DCE-MRI and were subsequently treated with sunitinib. Pretreatment DCE-MRI data on advanced HCC were analyzed using five different WX kinetic models: the Tofts-Kety (WX-TK), extended TK (WX-ETK), two compartment exchange, adiabatic approximation to tissue homogeneity (WX-AATH), and distributed parameter (WX-DP) models. The total hepatic blood flow, arterial flow fraction (γ), arterial blood flow (BFA), portal blood flow, blood volume, mean transit time, permeability-surface area product, fractional interstitial volume (vI), extraction fraction, mean intracellular water molecule lifetime (τC), and fractional intracellular volume (vC) were calculated. After receiver operating characteristic analysis with leave-one-out cross-validation, individual parameters for each model were assessed in terms of 1-year-survival (1YS) discrimination using Kaplan-Meier analysis, and association with overall survival (OS) using univariate Cox regression analysis with permutation testing. Results The WX-TK-model-derived γ (P = 0.022) and vI (P = 0.010), and WX-ETK-model-derived τC (P = 0.023) and vC (P = 0.042) were statistically significant prognostic biomarkers for 1YS. Increase in the WX-DP-model-derived BFA (P = 0.025) and decrease in the WX-TK, WX-ETK, WX-AATH, and WX-DP-model-derived vC (P = 0.034, P = 0.038, P = 0.028, P = 0.041, respectively) were significantly associated with an increase in OS. Conclusions The WX-ETK-model-derived vC was an effective prognostic biomarker for advanced HCC treated with sunitinib. PMID:26366997

  14. Some regularity on how to locate electrodes for higher fECG SNRs

    NASA Astrophysics Data System (ADS)

    Zhang, Jie-Min; Huang, Xiao-Lin; Guan, Qun; Liu, Tie-Bing; Li, Ping; Zhao, Ying; Liu, Hong-Xing

    2015-03-01

    The electrocardiogram (ECG) recorded from the abdominal surface of a pregnant woman is a composite of maternal ECG, fetal ECG (fECG) and other noises, while only the fECG component is always needed by us. With different locations of electrode pairs on the maternal abdominal surface to measure fECGs, the signal-to-noise ratios (SNRs) of the recorded abdominal ECGs are also correspondingly different. Some regularity on how to locate electrodes to obtain higher fECG SNRs is needed practically. In this paper, 343 groups of abdominal ECG records were acquired from 78 pregnant women with different electrode pairs locating, and an appropriate extended research database is formed. Then the regularity on fECG SNRs corresponding to different electrode pairs locating was studied. Based on statistical analysis, it is shown that the fECG SNRs are significantly higher in certain locations than others. Reasonable explanation is also provided to the statistical result using the theories of the fetal cardiac electrical axis and the signal phase delay. Project supported by the National Natural Science Foundation of China (Grant No. 61271079) and the Supporting Plan Project of Jiangsu Province, China (Grant No. BE2010720).

  15. Demonstration of a fully differential VGA chip with small THD for ECG acquisition system

    NASA Astrophysics Data System (ADS)

    Gongli, Xiao; Yuliang, Qin; Weilin, Xu; Baolin, Wei; Jihai, Duan; Xueming, Wei

    2015-10-01

    We present both a theoretical and experimental demonstration of a fully differential variable gain amplifier (VGA) with small total harmonic distortion (THD) for an electrocardiogram (ECG) acquisition system. Capacitive feedback technology is adopted to reduce the nonlinearity of VGA. The fully differential VGA has been fabricated in SMIC 0.18-μm CMOS process, and it only occupies 0.11 mm2. The measurements are in good agreement with simulation results. Experimental results show that the gain of VGA changes from 6.17 to 43.75 dB with a gain step of 3 dB. The high-pass corner frequency and low-pass corner frequency are around 0.22 Hz and 7.9 kHz, respectively. For each gain configuration, a maximal THD of 0.13% is obtained. The fully differential VGA has a low THD and its key performance parameters are well satisfied with the demands of ECG acquisition system application in the UWB wireless body area network. Project supported by the National Natural Science Foundation of China (Nos. 61264001, 61465004, 61161003, 61166004), the Guangxi Natural Science Foundation (Nos. 2013GXNSFAA019333, 2013GXNSFAA019338), the Science and Technology Research Key Project of Guangxi Department of Education (No. 2013ZD026), and the Innovation Project of GUET Graduate Education (No. GDYCSZ201457).

  16. PocketECG: A New Noninvasive Method for Continuous and Real-Time ECG Monitoring-Initial Results in Children and Adolescents.

    PubMed

    Bieganowska, Katarzyna; Kaszuba, Agnieszka; Bieganowski, Maciej; Kaczmarek, Krzysztof

    2017-03-01

    Long-term ECG is widely used in diagnosis and assessment of many cardiac symptoms which may be caused by dangerous arrhythmias that sometimes can be difficult to document. The PocketECG system is a new technological solution for a long-term, noninvasive, continuous and real-time ECG monitoring that provides automatic diagnosis of dysrhythmias. ECG data transmission occurs over a mobile network. The goal of this study was to assess the reliability of long-term ECG recordings acquired with the PocketECG system. One hundred and fifteen patients (43 girls and 72 boys) of an average age of 15.5 ± 2.5 years were examined at the Department of Cardiology at the Children's Memorial Health Institute. Two simultaneous 24-h ECG recordings were conducted: one with a Holter monitor and one with the PocketECG system. A linear correlation was demonstrated between the two methods with regard to the recorded QRS complexes [H = 1173.0 (-1946.40; 4838.50) + PocketECG*0.98 (0.94; 1.02)]. Mean diurnal heart rhythms were comparable (p > 0.05) despite the fact that the slowest and the fastest rates were different. The rate of detection for ventricular, supraventricular dysrhythmias and pauses in ventricular rhythm were comparable in both methods. The PocketECG system for continuous and real-time ECG recording is a reliable method for the assessment of heart rhythm and dysrhythmias in children and adolescents.

  17. QRS complex detection in ECG signal for wearable devices.

    PubMed

    Arefin, M Riadh; Tavakolian, Kouhyar; Fazel-Rezai, Reza

    2015-01-01

    This paper presents QRS complex detection algorithm based on dual slope technique, which is suitable for wearable electrocardiogram (ECG) applications. For cardiac patients of different arrhythmias, ECG signals are needed to be monitored over an extensive period of time. Thus, the wearable heart monitoring system needs computationally efficient QRS detection technique with good accuracy. In this paper, a method of QRS detection based on two slopes on both sides of an R peak is presented which is computationally efficient. Based on the slopes, first, a variable measuring steepness is developed, then by introducing an adjustable R-R interval based window and adaptive thresholding techniques, depending on the number of peaks detected in such window, R peaks are detected. The algorithm was evaluated against MIT/BIH arrhythmia database and achieved 99.16% detection rate with sensitivity of 0.9935 and positive predictivity of 0.9981. The method was compared with two widely used R peaks detection algorithms.

  18. Patient ECG recording control for an automatic implantable defibrillator

    NASA Technical Reports Server (NTRS)

    Fountain, Glen H. (Inventor); Lee, Jr., David G. (Inventor); Kitchin, David A. (Inventor)

    1986-01-01

    An implantable automatic defibrillator includes sensors which are placed on or near the patient's heart to detect electrical signals indicative of the physiology of the heart. The signals are digitally converted and stored into a FIFO region of a RAM by operation of a direct memory access (DMA) controller. The DMA controller operates transparently with respect to the microprocessor which is part of the defibrillator. The implantable defibrillator includes a telemetry communications circuit for sending data outbound from the defibrillator to an external device (either a patient controller or a physician's console or other) and a receiver for sensing at least an externally generated patient ECG recording command signal. The patient recording command signal is generated by the hand held patient controller. Upon detection of the patient ECG recording command, DMA copies the contents of the FIFO into a specific region of the RAM.

  19. Using ordinal partition transition networks to analyze ECG data

    NASA Astrophysics Data System (ADS)

    Kulp, Christopher W.; Chobot, Jeremy M.; Freitas, Helena R.; Sprechini, Gene D.

    2016-07-01

    Electrocardiogram (ECG) data from patients with a variety of heart conditions are studied using ordinal pattern partition networks. The ordinal pattern partition networks are formed from the ECG time series by symbolizing the data into ordinal patterns. The ordinal patterns form the nodes of the network and edges are defined through the time ordering of the ordinal patterns in the symbolized time series. A network measure, called the mean degree, is computed from each time series-generated network. In addition, the entropy and number of non-occurring ordinal patterns (NFP) is computed for each series. The distribution of mean degrees, entropies, and NFPs for each heart condition studied is compared. A statistically significant difference between healthy patients and several groups of unhealthy patients with varying heart conditions is found for the distributions of the mean degrees, unlike for any of the distributions of the entropies or NFPs.

  20. [Changes in ECG examination of patients with trichinosis].

    PubMed

    Siwak, E; Droń, D; Pancewicz, S; Zajkowska, J; Snarska, I; Szpakowicz, T; Januszkiewicz, E

    1994-07-01

    In the years 1963-1992, 560 patients with the diagnosis of trichinosis were treated in the Department of Parasitic Diseases and Neuroinfections, including 310 women (55.3%) and 250 men (44.7%) aged from 6 to 75 years. Out of this number of patients in 59 cases (10.5%) myocardial damage was found in the course of the disease. The most frequently found changes in ECG record were ventricular repolarization disturbances (66.1%) which persisted in 18.6% of cases before discharge from the hospital. Depolarization disturbances accounted for 32.2% of cases and persisted before discharge from the hospital in 10.1% of patients. In 6.7% of patients, persistence of pathological ECG record was found during the 4th month after the hospitalization which may be an evidence of prolongation of the inflammatory process within the myocardium.

  1. Using ordinal partition transition networks to analyze ECG data.

    PubMed

    Kulp, Christopher W; Chobot, Jeremy M; Freitas, Helena R; Sprechini, Gene D

    2016-07-01

    Electrocardiogram (ECG) data from patients with a variety of heart conditions are studied using ordinal pattern partition networks. The ordinal pattern partition networks are formed from the ECG time series by symbolizing the data into ordinal patterns. The ordinal patterns form the nodes of the network and edges are defined through the time ordering of the ordinal patterns in the symbolized time series. A network measure, called the mean degree, is computed from each time series-generated network. In addition, the entropy and number of non-occurring ordinal patterns (NFP) is computed for each series. The distribution of mean degrees, entropies, and NFPs for each heart condition studied is compared. A statistically significant difference between healthy patients and several groups of unhealthy patients with varying heart conditions is found for the distributions of the mean degrees, unlike for any of the distributions of the entropies or NFPs.

  2. ECG contamination of EEG signals: effect on entropy.

    PubMed

    Chakrabarti, Dhritiman; Bansal, Sonia

    2016-02-01

    Entropy™ is a proprietary algorithm which uses spectral entropy analysis of electroencephalographic (EEG) signals to produce indices which are used as a measure of depth of hypnosis. We describe a report of electrocardiographic (ECG) contamination of EEG signals leading to fluctuating erroneous Entropy values. An explanation is provided for mechanism behind this observation by describing the spread of ECG signals in head and neck and its influence on EEG/Entropy by correlating the observation with the published Entropy algorithm. While the Entropy algorithm has been well conceived, there are still instances in which it can produce erroneous values. Such erroneous values and their cause may be identified by close scrutiny of the EEG waveform if Entropy values seem out of sync with that expected at given anaesthetic levels.

  3. DCE-MRI Perfusion and Permeability Parameters as predictors of tumor response to CCRT in Patients with locally advanced NSCLC

    PubMed Central

    Tao, Xiuli; Wang, Lvhua; Hui, Zhouguang; Liu, Li; Ye, Feng; Song, Ying; Tang, Yu; Men, Yu; Lambrou, Tryphon; Su, Zihua; Xu, Xiao; Ouyang, Han; Wu, Ning

    2016-01-01

    In this prospective study, 36 patients with stage III non-small cell lung cancers (NSCLC), who underwent dynamic contrast-enhanced MRI (DCE-MRI) before concurrent chemo-radiotherapy (CCRT) were enrolled. Pharmacokinetic analysis was carried out after non-rigid motion registration. The perfusion parameters [including Blood Flow (BF), Blood Volume (BV), Mean Transit Time (MTT)] and permeability parameters [including endothelial transfer constant (Ktrans), reflux rate (Kep), fractional extravascular extracellular space volume (Ve), fractional plasma volume (Vp)] were calculated, and their relationship with tumor regression was evaluated. The value of these parameters on predicting responders were calculated by receiver operating characteristic (ROC) curve. Multivariate logistic regression analysis was conducted to find the independent variables. Tumor regression rate is negatively correlated with Ve and its standard variation Ve_SD and positively correlated with Ktrans and Kep. Significant differences between responders and non-responders existed in Ktrans, Kep, Ve, Ve_SD, MTT, BV_SD and MTT_SD (P < 0.05). ROC indicated that Ve < 0.24 gave the largest area under curve of 0.865 to predict responders. Multivariate logistic regression analysis also showed Ve was a significant predictor. Baseline perfusion and permeability parameters calculated from DCE-MRI were seen to be a viable tool for predicting the early treatment response after CCRT of NSCLC. PMID:27762331

  4. [Development of a portable dynamic state ECG based on DSP].

    PubMed

    Song, Li; Meng, Qing-jian; Zhang, Guang-yu; Cao, Wei-fang

    2009-11-01

    The Portable dynamic state electrocardiogram collecting system is introduced by using TMS302VC5402, TLC320AD50C, liquid crystal display model, and so on. This dissertation describes the work principle of the system and uses the united algorithm based on wavelet to identify and locate the ECG characteristic waves. This system has as follows of advantages: big memory, low noise,high common mode rejection ratio, the low power consume,the long record time etc.

  5. Clinical disease presentation and ECG characteristics of LMNA mutation carriers

    PubMed Central

    Ollila, Laura; Nikus, Kjell; Holmström, Miia; Jalanko, Mikko; Jurkko, Raija; Kaartinen, Maija; Koskenvuo, Juha; Kuusisto, Johanna; Kärkkäinen, Satu; Palojoki, Eeva; Reissell, Eeva; Piirilä, Päivi; Heliö, Tiina

    2017-01-01

    Objective Mutations in the LMNA gene encoding lamins A and C of the nuclear lamina are a frequent cause of cardiomyopathy accounting for 5–8% of familial dilated cardiomyopathy (DCM). Our aim was to study disease onset, presentation and progression among LMNA mutation carriers. Methods Clinical follow-up data from 27 LMNA mutation carriers and 78 patients with idiopathic DCM without an LMNA mutation were collected. In addition, ECG data were collected and analysed systematically from 20 healthy controls. Results Kaplan-Meier analysis revealed no difference in event-free survival (death, heart transplant, resuscitation and appropriate implantable cardioverter-defibrillator therapy included as events) between LMNA mutation carriers and DCM controls (p=0.5). LMNA mutation carriers presented with atrial fibrillation at a younger age than the DCM controls (47 vs 57 years, p=0.003). Male LMNA mutation carriers presented with clinical manifestations roughly a decade earlier than females. In close follow-up non-sustained ventricular tachycardia was detected in 78% of LMNA mutation carriers. ECG signs of septal remodelling were present in 81% of the LMNA mutation carriers, 21% of the DCM controls and none of the healthy controls giving a high sensitivity and specificity for the standard ECG in distinguishing LMNA mutation carriers from patients with DCM and healthy controls. Conclusions Male LMNA mutation carriers present clinical manifestations at a younger age than females. ECG septal remodelling appears to distinguish LMNA mutation carriers from healthy controls and patients with DCM without LMNA mutations. PMID:28123761

  6. Discussion of "Computational Electrocardiography: Revisiting Holter ECG Monitoring".

    PubMed

    Baumgartner, Christian; Caiani, Enrico G; Dickhaus, Hartmut; Kulikowski, Casimir A; Schiecke, Karin; van Bemmel, Jan H; Witte, Herbert

    2016-08-05

    This article is part of a For-Discussion-Section of Methods of Information in Medicine about the paper "Computational Electrocardiography: Revisiting Holter ECG Monitoring" written by Thomas M. Deserno and Nikolaus Marx. It is introduced by an editorial. This article contains the combined commentaries invited to independently comment on the paper of Deserno and Marx. In subsequent issues the discussion can continue through letters to the editor.

  7. Evaluation of repolarization dynamics using the QT-RR regression line slope and intercept relationship during 24-h Holter ECG.

    PubMed

    Fujiki, Akira; Yoshioka, Ryozo; Sakabe, Masao

    2015-03-01

    QT-RR linear regression consists of two parameters, slope and intercept, and the aim of this study was to evaluate repolarization dynamics using the QT-RR linear regression slope and intercept relationship during 24-h Holter ECG. This study included 466 healthy subjects (54.6 ± 14.6 years; 200 men and 266 women) and 17 patients with ventricular arrhythmias, consisted of 10 patients with idiopathic ventricular fibrillation (IVF) and 7 patients with torsades de pointes (TDP). QT and RR intervals were measured from ECG waves based on a 15-s averaged ECG during 24-h Holter recording using an automatic QT analyzing system. The QT interval dependence on the RR interval was analyzed using a linear regression line for each subject ([QT] = A[RR] + B; where A is the slope and B is the y-intercept). The slope of the QT-RR regression line in healthy subjects was significantly greater in women than in men (0.185 ± 0.036 vs. 0.161 ± 0.033, p < 0.001) and the intercept was significantly smaller in women than in men (0.229 ± 0.028 vs. 0.240 ± 0.027, p < 0.001). A scatter diagram of the QT-RR regression line slope and intercept among healthy subjects demonstrated a statistically significant negative correlation (B = -0.62A + 0.34, r = -0.79). Distribution of both scatter diagrams of the slope and the intercept of the QT-RR regression line in patients with IVF and TDP was different from healthy subjects (left corner for IVF and upward shift for TDP). The slope and intercept relationship of the QT-RR linear regression line based on 24-h Holter ECG may become a simple useful marker for abnormality of ventricular repolarization dynamics.

  8. Comparative Analysis of the Equivital EQ02 Lifemonitor with Holter Ambulatory ECG Device for Continuous Measurement of ECG, Heart Rate, and Heart Rate Variability: A Validation Study for Precision and Accuracy.

    PubMed

    Akintola, Abimbola A; van de Pol, Vera; Bimmel, Daniel; Maan, Arie C; van Heemst, Diana

    2016-01-01

    Background: The Equivital (EQ02) is a multi-parameter telemetric device offering both real-time and/or retrospective, synchronized monitoring of ECG, HR, and HRV, respiration, activity, and temperature. Unlike the Holter, which is the gold standard for continuous ECG measurement, EQO2 continuously monitors ECG via electrodes interwoven in the textile of a wearable belt. Objective: To compare EQ02 with the Holter for continuous home measurement of ECG, heart rate (HR), and heart rate variability (HRV). Methods: Eighteen healthy participants wore, simultaneously for 24 h, the Holter and EQ02 monitors. Per participant, averaged HR, and HRV per 5 min from the two devices were compared using Pearson correlation, paired T-test, and Bland-Altman analyses. Accuracy and precision metrics included mean absolute relative difference (MARD). Results: Artifact content of EQ02 data varied widely between (range 1.93-56.45%) and within (range 0.75-9.61%) participants. Comparing the EQ02 to the Holter, the Pearson correlations were respectively 0.724, 0.955, and 0.997 for datasets containing all data and data with < 50 or < 20% artifacts respectively. For datasets containing respectively all data, data with < 50, or < 20% artifacts, bias estimated by Bland-Altman analysis was -2.8, -1.0, and -0.8 beats per minute and 24 h MARD was 7.08, 3.01, and 1.5. After selecting a 3-h stretch of data containing 1.15% artifacts, Pearson correlation was 0.786 for HRV measured as standard deviation of NN intervals (SDNN). Conclusions: Although the EQ02 can accurately measure ECG and HRV, its accuracy and precision is highly dependent on artifact content. This is a limitation for clinical use in individual patients. However, the advantages of the EQ02 (ability to simultaneously monitor several physiologic parameters) may outweigh its disadvantages (higher artifact load) for research purposes and/ or for home monitoring in larger groups of study participants. Further studies can be aimed at

  9. Comparative Analysis of the Equivital EQ02 Lifemonitor with Holter Ambulatory ECG Device for Continuous Measurement of ECG, Heart Rate, and Heart Rate Variability: A Validation Study for Precision and Accuracy

    PubMed Central

    Akintola, Abimbola A.; van de Pol, Vera; Bimmel, Daniel; Maan, Arie C.; van Heemst, Diana

    2016-01-01

    Background: The Equivital (EQ02) is a multi-parameter telemetric device offering both real-time and/or retrospective, synchronized monitoring of ECG, HR, and HRV, respiration, activity, and temperature. Unlike the Holter, which is the gold standard for continuous ECG measurement, EQO2 continuously monitors ECG via electrodes interwoven in the textile of a wearable belt. Objective: To compare EQ02 with the Holter for continuous home measurement of ECG, heart rate (HR), and heart rate variability (HRV). Methods: Eighteen healthy participants wore, simultaneously for 24 h, the Holter and EQ02 monitors. Per participant, averaged HR, and HRV per 5 min from the two devices were compared using Pearson correlation, paired T-test, and Bland-Altman analyses. Accuracy and precision metrics included mean absolute relative difference (MARD). Results: Artifact content of EQ02 data varied widely between (range 1.93–56.45%) and within (range 0.75–9.61%) participants. Comparing the EQ02 to the Holter, the Pearson correlations were respectively 0.724, 0.955, and 0.997 for datasets containing all data and data with < 50 or < 20% artifacts respectively. For datasets containing respectively all data, data with < 50, or < 20% artifacts, bias estimated by Bland-Altman analysis was −2.8, −1.0, and −0.8 beats per minute and 24 h MARD was 7.08, 3.01, and 1.5. After selecting a 3-h stretch of data containing 1.15% artifacts, Pearson correlation was 0.786 for HRV measured as standard deviation of NN intervals (SDNN). Conclusions: Although the EQ02 can accurately measure ECG and HRV, its accuracy and precision is highly dependent on artifact content. This is a limitation for clinical use in individual patients. However, the advantages of the EQ02 (ability to simultaneously monitor several physiologic parameters) may outweigh its disadvantages (higher artifact load) for research purposes and/ or for home monitoring in larger groups of study participants. Further studies can be aimed

  10. Real-time ECG transmission via Internet for nonclinical applications.

    PubMed

    Hernández, A I; Mora, F; Villegas, G; Passariello, G; Carrault, G

    2001-09-01

    Telemedicine is producing a great impact in the monitoring of patients located in remote nonclinical environments such as homes, elder communities, gymnasiums, schools, remote military bases, ships, and the like. A number of applications, ranging from data collection, to chronic patient surveillance, and even to the control of therapeutic procedures, are being implemented in many parts of the world. As part of this growing trend, this paper discusses the problems in electrocardiogram (ECG) real-time data acquisition, transmission, and visualization over the Internet. ECG signals are transmitted in real time from a patient in a remote nonclinical environment to the specialist in a hospital or clinic using the current capabilities and availability of the Internet. A prototype system is composed of a portable data acquisition and preprocessing module connected to the computer in the remote site via its RS-232 port, a Java-based client-server platform, and software modules to handle communication protocols between data acquisition module and the patient's personal computer, and to handle client-server communication. The purpose of the system is the provision of extended monitoring for patients under drug therapy after infarction, data collection in some particular cases, remote consultation, and low-cost ECG monitoring for the elderly.

  11. Compressive sensing exploiting wavelet-domain dependencies for ECG compression

    NASA Astrophysics Data System (ADS)

    Polania, Luisa F.; Carrillo, Rafael E.; Blanco-Velasco, Manuel; Barner, Kenneth E.

    2012-06-01

    Compressive sensing (CS) is an emerging signal processing paradigm that enables sub-Nyquist sampling of sparse signals. Extensive previous work has exploited the sparse representation of ECG signals in compression applications. In this paper, we propose the use of wavelet domain dependencies to further reduce the number of samples in compressive sensing-based ECG compression while decreasing the computational complexity. R wave events manifest themselves as chains of large coefficients propagating across scales to form a connected subtree of the wavelet coefficient tree. We show that the incorporation of this connectedness as additional prior information into a modified version of the CoSaMP algorithm can significantly reduce the required number of samples to achieve good quality in the reconstruction. This approach also allows more control over the ECG signal reconstruction, in particular, the QRS complex, which is typically distorted when prior information is not included in the recovery. The compression algorithm was tested upon records selected from the MIT-BIH arrhythmia database. Simulation results show that the proposed algorithm leads to high compression ratios associated with low distortion levels relative to state-of-the-art compression algorithms.

  12. Robust electrocardiogram (ECG) beat classification using discrete wavelet transform.

    PubMed

    Minhas, Fayyaz-ul-Amir Afsar; Arif, Muhammad

    2008-05-01

    This paper presents a robust technique for the classification of six types of heartbeats through an electrocardiogram (ECG). Features extracted from the QRS complex of the ECG using a wavelet transform along with the instantaneous RR-interval are used for beat classification. The wavelet transform utilized for feature extraction in this paper can also be employed for QRS delineation, leading to reduction in overall system complexity as no separate feature extraction stage would be required in the practical implementation of the system. Only 11 features are used for beat classification with the classification accuracy of approximately 99.5% through a KNN classifier. Another main advantage of this method is its robustness to noise, which is illustrated in this paper through experimental results. Furthermore, principal component analysis (PCA) has been used for feature reduction, which reduces the number of features from 11 to 6 while retaining the high beat classification accuracy. Due to reduction in computational complexity (using six features, the time required is approximately 4 ms per beat), a simple classifier and noise robustness (at 10 dB signal-to-noise ratio, accuracy is 95%), this method offers substantial advantages over previous techniques for implementation in a practical ECG analyzer.

  13. Unsupervised feature relevance analysis applied to improve ECG heartbeat clustering.

    PubMed

    Rodríguez-Sotelo, J L; Peluffo-Ordoñez, D; Cuesta-Frau, D; Castellanos-Domínguez, G

    2012-10-01

    The computer-assisted analysis of biomedical records has become an essential tool in clinical settings. However, current devices provide a growing amount of data that often exceeds the processing capacity of normal computers. As this amount of information rises, new demands for more efficient data extracting methods appear. This paper addresses the task of data mining in physiological records using a feature selection scheme. An unsupervised method based on relevance analysis is described. This scheme uses a least-squares optimization of the input feature matrix in a single iteration. The output of the algorithm is a feature weighting vector. The performance of the method was assessed using a heartbeat clustering test on real ECG records. The quantitative cluster validity measures yielded a correctly classified heartbeat rate of 98.69% (specificity), 85.88% (sensitivity) and 95.04% (general clustering performance), which is even higher than the performance achieved by other similar ECG clustering studies. The number of features was reduced on average from 100 to 18, and the temporal cost was a 43% lower than in previous ECG clustering schemes.

  14. Fast clustering algorithm for large ECG data sets based on CS theory in combination with PCA and K-NN methods.

    PubMed

    Balouchestani, Mohammadreza; Krishnan, Sridhar

    2014-01-01

    Long-term recording of Electrocardiogram (ECG) signals plays an important role in health care systems for diagnostic and treatment purposes of heart diseases. Clustering and classification of collecting data are essential parts for detecting concealed information of P-QRS-T waves in the long-term ECG recording. Currently used algorithms do have their share of drawbacks: 1) clustering and classification cannot be done in real time; 2) they suffer from huge energy consumption and load of sampling. These drawbacks motivated us in developing novel optimized clustering algorithm which could easily scan large ECG datasets for establishing low power long-term ECG recording. In this paper, we present an advanced K-means clustering algorithm based on Compressed Sensing (CS) theory as a random sampling procedure. Then, two dimensionality reduction methods: Principal Component Analysis (PCA) and Linear Correlation Coefficient (LCC) followed by sorting the data using the K-Nearest Neighbours (K-NN) and Probabilistic Neural Network (PNN) classifiers are applied to the proposed algorithm. We show our algorithm based on PCA features in combination with K-NN classifier shows better performance than other methods. The proposed algorithm outperforms existing algorithms by increasing 11% classification accuracy. In addition, the proposed algorithm illustrates classification accuracy for K-NN and PNN classifiers, and a Receiver Operating Characteristics (ROC) area of 99.98%, 99.83%, and 99.75% respectively.

  15. Capacitive ECG system with direct access to standard leads and body surface potential mapping.

    PubMed

    Oehler, Martin; Schilling, Meinhard; Esperer, Hans Dieter

    2009-12-01

    Capacitive electrodes provide the same access to the human electrocardiogram (ECG) as galvanic electrodes, but without the need of direct electrical skin contact and even through layers of clothing. Thus, potential artifacts as a result of poor electrode contact to the skin are avoided and preparation time is significantly reduced. Our system integrates such capacitive electrodes in a 15 sensor array, which is combined with a Tablet PC. This integrated lightweight ECG system (cECG) is easy to place on the chest wall and allows for simultaneous recordings of 14 ECG channels, even if the patient is slightly dressed, e.g., with a t-shirt. In this paper, we present preliminary results on the performance of the cECG regarding the capability of recording body surface potential maps (BSPMs) and obtaining reconstructed standard ECG leads including Einthoven, Goldberger and, with some limitations, Wilson leads. All signals were measured having the subject lie in a supine position and wear a cotton shirt. Signal quality and diagnostic ECG information of the extracted leads are compared with standard ECG measurements. The results show a very close correlation between both types of ECG measurements. It is concluded that the cECG lends itself to rapid screening in clinically unstable patients.

  16. Measurements on wireless transmission of ECG signals

    NASA Astrophysics Data System (ADS)

    Gabrielli, A.; Lax, I.

    2016-12-01

    The scope of this research is to design an electronic prototype, an operative system as a proof of concept, to transmit and receive biological parameters, in particular electrocardiogram signals, through dedicated wireless circuits. The apparatus features microelectronics chips that were developed for more general biomedical applications, here adapted to deal with cardiac signals. The paper mainly focuses on the electronic aspects, as in this study we do not face medical or clinical aspects of the system. The transmitter circuit uses a commercial instrumentation amplifier and the receiver has been equipped with wide-band amplifiers along with made-in-the-lab band-pass filters centered at the carrier. We have been able to mount the entire system prototype into a preliminary data acquisition chain that reads out the electrocardiogram signal. The prototype allows acquiring the waveform, converting it to a digital pattern and open the transmission through a series of high-frequency packets exploiting the Ultra Wide Band protocol. The sensor value is embedded in the transmission through the rate of the digital packets. In fact, these are sent wireless at a specific packet-frequency that depends on the sensor amplitude and are detected into a receiver circuit that recovers the information.

  17. Fast QRS Detection with an Optimized Knowledge-Based Method: Evaluation on 11 Standard ECG Databases

    PubMed Central

    Elgendi, Mohamed

    2013-01-01

    The current state-of-the-art in automatic QRS detection methods show high robustness and almost negligible error rates. In return, the methods are usually based on machine-learning approaches that require sufficient computational resources. However, simple-fast methods can also achieve high detection rates. There is a need to develop numerically efficient algorithms to accommodate the new trend towards battery-driven ECG devices and to analyze long-term recorded signals in a time-efficient manner. A typical QRS detection method has been reduced to a basic approach consisting of two moving averages that are calibrated by a knowledge base using only two parameters. In contrast to high-accuracy methods, the proposed method can be easily implemented in a digital filter design. PMID:24066054

  18. Simultaneous powerline interference and baseline wander removal from ECG and EMG signals by sinusoidal modeling.

    PubMed

    Zivanovic, Miroslav; González-Izal, Miriam

    2013-10-01

    We present a compact approach to joint modeling of powerline interference (PLI) and baseline wonder (BW) for denoising of biopotential signals. Both PLI and BW are modeled by a set of harmonically related sinusoids modulated by low-order time polynomials. The sinusoids account on the harmonicity and mean instantaneous frequency of the PLI in the analysis window, while the polynomials capture the frequency and amplitude deviations from their nominal values and characterize the BW at the same time. The resulting model is linear-in-parameters and the solution to the corresponding linear system is estimated in a simple and efficient way through linear least-squares. The proposed modeling method was evaluated on real electrocardiographic (ECG) and electromyographic (EMG) signals against three reference methods for different analysis scenarios. The comparative study suggests that the proposed method outperforms the reference methods in terms of residual interference energy in the denoised biopotential signals.

  19. Temporal and spatial gait parameters in patients dependent on walking assistance after stroke: reliability and agreement between simple and advanced methods of assessment.

    PubMed

    Høyer, Ellen; Opheim, Arve; Strand, Liv Inger; Moe-Nilssen, Rolf

    2014-01-01

    The aim of this study was to investigate the reliability of temporal and spatial gait parameters in patients dependent on walking assistance after severe stroke, and to examine agreement between simple and advanced methods. Twenty-one patients, admitted for in-patient multidisciplinary rehabilitation, were assessed repeatedly for walking function, both in a test corridor and a gait laboratory (3D camera system) before and after 11 weeks of rehabilitation. The test-retest reliability was examined using intraclass correlation (ICC1.1), and measurement error was reported by within-subject standard deviation (Sw). The agreement between different methods for assessing walking speed, cadence and step length was explored by Bland-Altman plots. High to excellent test-retest reliability was found between trials, both when assessed in the corridor (ICC: 0.93-0.99) and in the laboratory (ICC: 0.88-0.99). Agreement between methods was satisfactory at baseline and was higher after the rehabilitation period. Agreement was found to be slightly better at lower walking speeds and for shorter step lengths. The results implicate that temporal-spatial gait parameters may be measured reliably by both simple and advanced methods in dependent walkers after stroke. A high level of agreement was found between the two methods for walking speed, cadence and average step length at both test points.

  20. Noise and baseline wandering suppression of ECG signals by morphological filter.

    PubMed

    Taouli, S A; Bereksi-Reguig, F

    2010-02-01

    Electrocardiogram (ECG) signals describe the electrical activity of the heart, and are universally by physicists in the diagnosis of cardiac pathologies. However, during the acquisition of ECGs they are often contaminated with different sources of noise, making interpretation difficult. Different techniques have been used to filter the ECG signal, in order to optimize the signal to noise ratio (S/N). In this paper, an approach based on morphological filtering is developed in order to filter the ECG. Morphological filtering is concerned with the detection of the ECG morphology, therefore allowing the suppression of noises and particularly baseline wandering. The implemented filter is evaluated using signals taken from the MIT-BIH ECG universal database. The results show that the performance of this filter is good compared with other filtering techniques.

  1. Software design of a remote real-time ECG monitoring system

    NASA Astrophysics Data System (ADS)

    Yu, Chengbo; Tao, Hongyan

    2005-12-01

    Heart disease is one of the main diseases that threaten the health and lives of human beings. At present, the normal remote ECG monitoring system has the disadvantages of a short testing distance and limitation of monitoring lines. Because of accident and paroxysmal disease, ECG monitoring has extended from the hospital to the family. Therefore, remote ECG monitoring through the Internet has the actual value and significance. The principle and design method of software of the remote dynamic ECG monitor was presented and discussed. The monitoring software is programmed with Delphi software based on client-sever interactive mode. The application program of the system, which makes use of multithreading technology, is shown to perform in an excellent manner. The program includes remote link users and ECG processing, i.e. ECG data's receiving, real-time displaying, recording and replaying. The system can connect many clients simultaneously and perform real-time monitoring to patients.

  2. Short-term ECG recording for the identification of cardiac autonomic neuropathy in people with diabetes mellitus

    NASA Astrophysics Data System (ADS)

    Jelinek, Herbert F.; Pham, Phuong; Struzik, Zbigniew R.; Spence, Ian

    2007-07-01

    Diabetes mellitus (DM) is a serious and increasing health problem worldwide. Compared to non-diabetics, patients experience an increased risk of all cardiovascular diseases, including dysfunctional neural control of the heart. Poor diagnoses of cardiac autonomic neuropathy (CAN) may result in increased incidence of silent myocardial infarction and ischaemia, which can lead to sudden death. Traditionally the Ewing battery of tests is used to identify CAN. The purpose of this study is to examine the usefulness of heart rate variability (HRV) analyses of short-term ECG recordings as a method for detecting CAN. HRV may be able to identify asymptomatic individuals, which the Ewing battery is not able to do. Several HRV parameters are assessed, including time and frequency domain, as well as nonlinear parameters. Eighteen out of thirty-eight individuals with diabetes were positive for two or more of the Ewing battery of tests indicating CAN. Approximate Entropy (ApEn), log normalized total power (LnTP) and log normalized high frequency (LnHF) power demonstrate a significant difference at p < 0.05 between CAN+ and CAN-. This indicates that nonlinear scaling parameters are able to identify people with cardiac autonomic neuropathy in short ECG recordings. Our study paves the way to assess the utility of nonlinear parameters in identifying asymptomatic CAN.

  3. Approximating large resonance parameter covariance matrices with group-wise covariance matrices for advanced nuclear fuel cycle applications

    SciTech Connect

    Dunn, Michael E; Leal, Luiz C; Wiarda, Dorothea; Arbanas, Goran

    2008-01-01

    The large size of resonance parameter covariance matrices (RPCM) in the actinide region often renders them impractical for dissemination via ENDF. Therefore, a method of approximating the RPCM by a much smaller group-wise covariance matrix (GWCM) is described, implemented, and examined. In this work, 233U RPCM is used to generate GWCM's for the 44 group AMPX, 100 group GE, 171 group VITAMIN-C, and 240 group CSWEG. Each of these GWCM's is then used to compute group-wise uncertainties for the groups of the remaining group structures. The group-wise uncertainties thus obtained are compared with those obtained from a full RPCM, i.e. without the approximation. A systematic comparison of group-wise uncertainties based on GWCM's vs. RPCM, for a variety of group structures, will shed light on the validity of this approximation and may suggest which group structure(s) yield a GWCM that could be used in lieu of the RPCM.

  4. On the improved correlative prediction scheme for aliased electrocardiogram (ECG) data compression.

    PubMed

    Gao, Xin

    2012-01-01

    An improved scheme for aliased electrocardiogram (ECG) data compression has been constructed, where the predictor exploits the correlative characteristics of adjacent QRS waveforms. The twin-R correlation prediction and lifting wavelet transform (LWT) for periodical ECG waves exhibits feasibility and high efficiency to achieve lower distortion rates with realizable compression ratio (CR); grey predictions via GM(1, 1) model have been adopted to evaluate the parametric performance for ECG data compression. Simulation results illuminate the validity of our approach.

  5. Development of a portable wireless system for bipolar concentric ECG recording

    NASA Astrophysics Data System (ADS)

    Prats-Boluda, G.; Ye-Lin, Y.; Bueno Barrachina, J. M.; Senent, E.; Rodriguez de Sanabria, R.; Garcia-Casado, J.

    2015-07-01

    Cardiovascular diseases (CVDs) remain the biggest cause of deaths worldwide. ECG monitoring is a key tool for early diagnosis of CVDs. Conventional monitors use monopolar electrodes resulting in poor spatial resolution surface recordings and requiring extensive wiring. High-spatial resolution surface electrocardiographic recordings provide valuable information for the diagnosis of a wide range of cardiac abnormalities, including infarction and arrhythmia. The aim of this work was to develop and test a wireless recording system for acquiring high spatial resolution ECG signals, based on a flexible tripolar concentric electrode (TCE) without cable wiring or external reference electrode which would make more comnfortable its use in clinical practice. For this, a portable, wireless sensor node for analogue conditioning, digitalization and transmission of a bipolar concentric ECG signal (BC-ECG) using a TCE and a Mason-likar Lead-I ECG (ML-Lead-I ECG) signal was developed. Experimental results from a total of 32 healthy volunteers showed that the ECG fiducial points in the BC-ECG signals, recorded with external and internal reference electrode, are consistent with those of simultaneous ML-Lead-I ECG. No statistically significant difference was found in either signal amplitude or morphology, regardless of the reference electrode used, being the signal-to-noise similar to that of ML-Lead-I ECG. Furthermore, it has been observed that BC-ECG signals contain information that could not available in conventional records, specially related to atria activity. The proposed wireless sensor node provides non-invasive high-local resolution ECG signals using only a TCE without additional wiring, which would have great potential in medical diagnosis of diseases such as atrial or ventricular fibrillations or arrhythmias that currently require invasive diagnostic procedures (catheterization).

  6. Brugada ECG Pattern Unmasked by IV Flecainide in an Individual with Idiopathic Fascicular Ventricular Tachycardia.

    PubMed

    Gavin, Andrew R; Young, Glenn D; McGavigan, Andrew D

    2013-01-01

    A 45-year old man presents with stable monomorphic ventricular tachycardia. He had previously been diagnosed with idiopathic fascicular ventricular tachycardia. Intravenous flecainide results in termination of his tachycardia but unmasks a latent type 1 Brugada ECG pattern not seen on his resting ECG. We discuss his subsequent management and the need to consider an alternative diagnosis in individuals with a Brugada type ECG pattern who present with stable monomorphic ventricular tachycardia.

  7. Prognostic Value of Baseline 18F-FDG PET/CT Functional Parameters in Patients with Advanced Lung Adenocarcinoma Stratified by EGFR Mutation Status

    PubMed Central

    Wang, Dalong; Zhang, Minghui; Gao, Xuan; Yu, Lijuan

    2016-01-01

    The study objective was to retrospectively analyze the metabolic variables derived from 18 F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) as predictors of progression-free survival (PFS) and overall survival (OS) in advanced lung adenocarcinoma stratified by epidermal growth factor receptor (EGFR) mutation status. A total of 176 patients (91, EGFR mutation; 85, wild-type EGFR) who underwent 18F-FDG PET/CT before treatment were enrolled. The main 18F-FDG PET/CT-derived variables: primary tumor maximum standardized uptake value (SUVmaxT), primary tumor total lesion glycolysis (TLGT), the maximum SUVmax of all selected lesions in whole body determined using the Response Evaluation Criteria In Solid Tumors (RECIST) 1.1 criteria (SUVmaxWBR), and whole-body total TLG determined using the RECIST 1.1 criteria (TLGWBR) were measured. Survival analysis regarding TLGWBR, and other factors in advanced lung adenocarcinoma patients stratified using EGFR mutation status, were evaluated. The results indicated that high TLGWBR (≥259.85), EGFR wild-type, and high serum LDH were independent predictors of worse PFS and OS in all patients with advanced lung adenocarcinoma. Among patients with wild-type EGFR, only TLGWBR retained significance as an independent predictor of both PFS and OS. Among patients with the EGFR mutation, high serum LDH level was an independent predictor of worse PFS and OS, and high TLGWBR (≥259.85) was an independent predictor of worse PFS but not worse OS. In conclusion, TLGWBR is a promising parameter for prognostic stratification of patients with advanced lung adenocarcinoma and EGFR status; however, it cannot be used to further stratify the risk of worse OS for patients with the EGFR mutation. Further prospective studies are needed to validate our findings. PMID:27336755

  8. Wavelet-based ECG compression by bit-field preserving and running length encoding.

    PubMed

    Chan, Hsiao-Lung; Siao, You-Chen; Chen, Szi-Wen; Yu, Shih-Fan

    2008-04-01

    Efficient electrocardiogram (ECG) compression can reduce the payload of real-time ECG transmission as well as reduce the amount of data storage in long-term ECG recording. In this paper an ECG compression/decompression architecture based on the bit-field preserving (BFP) and running length encoding (RLE)/decoding schemes incorporated with the discrete wavelet transform (DWT) is proposed. Compared to complex and repetitive manipulations in the set partitioning in hierarchical tree (SPIHT) coding and the vector quantization (VQ), the proposed algorithm has advantages of simple manipulations and a feedforward structure that would be suitable to implement on very-large-scale integrated circuits and general microcontrollers.

  9. ECG De-noising: A comparison between EEMD-BLMS and DWT-NN algorithms.

    PubMed

    Kærgaard, Kevin; Jensen, Søren Hjøllund; Puthusserypady, Sadasivan

    2015-08-01

    Electrocardiogram (ECG) is a widely used non-invasive method to study the rhythmic activity of the heart and thereby to detect the abnormalities. However, these signals are often obscured by artifacts from various sources and minimization of these artifacts are of paramount important. This paper proposes two adaptive techniques, namely the EEMD-BLMS (Ensemble Empirical Mode Decomposition in conjunction with the Block Least Mean Square algorithm) and DWT-NN (Discrete Wavelet Transform followed by Neural Network) methods in minimizing the artifacts from recorded ECG signals, and compares their performance. These methods were first compared on two types of simulated noise corrupted ECG signals: Type-I (desired ECG+noise frequencies outside the ECG frequency band) and Type-II (ECG+noise frequencies both inside and outside the ECG frequency band). Subsequently, they were tested on real ECG recordings. Results clearly show that both the methods works equally well when used on Type-I signals. However, on Type-II signals the DWT-NN performed better. In the case of real ECG data, though both methods performed similar, the DWT-NN method was a slightly better in terms of minimizing the high frequency artifacts.

  10. A Low Power Linear Phase Digital FIR Filter for Wearable ECG Devices.

    PubMed

    Lian, Yong; Yu, Jianghong

    2005-01-01

    In this paper we present a low power linear phase digital FIR filter which is a part of an ECG-on-Chip. The ECG-on-Chip can be embedded into clothing to acquire the electrocardiogram (ECG) signal and send a warning message to a mobile phone or PDA if an abnormal ECG is detected. The proposed new filter structure significantly reduces the arithmetic operations for each sample which in turn lowers the power consumption. The filter is developed based on the interpolated finite impulse filter technique and is very attractive for a low cost and low power VLSI implementation.

  11. Arrhythmia Classification Based on Multi-Domain Feature Extraction for an ECG Recognition System

    PubMed Central

    Li, Hongqiang; Yuan, Danyang; Wang, Youxi; Cui, Dianyin; Cao, Lu

    2016-01-01

    Automatic recognition of arrhythmias is particularly important in the diagnosis of heart diseases. This study presents an electrocardiogram (ECG) recognition system based on multi-domain feature extraction to classify ECG beats. An improved wavelet threshold method for ECG signal pre-processing is applied to remove noise interference. A novel multi-domain feature extraction method is proposed; this method employs kernel-independent component analysis in nonlinear feature extraction and uses discrete wavelet transform to extract frequency domain features. The proposed system utilises a support vector machine classifier optimized with a genetic algorithm to recognize different types of heartbeats. An ECG acquisition experimental platform, in which ECG beats are collected as ECG data for classification, is constructed to demonstrate the effectiveness of the system in ECG beat classification. The presented system, when applied to the MIT-BIH arrhythmia database, achieves a high classification accuracy of 98.8%. Experimental results based on the ECG acquisition experimental platform show that the system obtains a satisfactory classification accuracy of 97.3% and is able to classify ECG beats efficiently for the automatic identification of cardiac arrhythmias. PMID:27775596

  12. Embedding patients confidential data in ECG signal for healthcare information systems.

    PubMed

    Ibaida, Ayman; Khalil, Ibrahim; Al-Shammary, Dhiah

    2010-01-01

    In Wireless tele-cardiology applications, ECG signal is widely used to monitor cardiac activities of patients. Accordingly, in most e-health applications, ECG signals need to be combined with patient confidential information. Data hiding and watermarking techniques can play a crucial role in ECG wireless tele-monitoring systems by combining the confidential information with the ECG signal since digital ECG data is huge enough to act as host to carry tiny amount of additional secret data. In this paper, a new steganography technique is proposed that helps embed confidential information of patients into specific locations (called special range numbers) of digital ECG host signal that will cause minimal distortion to ECG, and at the same time, any secret information embedded is completely extractable. We show that there are 2.1475 × 10(9) possible special range numbers making it extremely difficult for intruders to identify locations of secret bits. Experiments show that percentage residual difference (PRD) of watermarked ECGs can be as low as 0.0247% and 0.0678% for normal and abnormal ECG segments (taken from MIT-BIH Arrhythmia database) respectively.

  13. The Telemetric and Holter ECG Warehouse (THEW): the first three years of development and research.

    PubMed

    Couderc, Jean-Philippe

    2012-01-01

    The Telemetric and Holter ECG Warehouse (THEW) hosts more than 3700 digital 24-Holter ECG recordings from 13 independent studies. In addition to the ECGs, the repository includes patient information in separate clinical database with content varying according to the study focus. In its third year of activities, the THEW database has been accessed by researchers from 37 universities and 16 corporations located in 16 countries worldwide. Twenty publications were released primarily focusing on the development and validation of ECG-based technologies. This communication describes the content of the databases of the repository with brief summary of the research and development projects completed using these data.

  14. A novel approach to ECG classification based upon two-layered HMMs in body sensor networks.

    PubMed

    Liang, Wei; Zhang, Yinlong; Tan, Jindong; Li, Yang

    2014-03-27

    This paper presents a novel approach to ECG signal filtering and classification. Unlike the traditional techniques which aim at collecting and processing the ECG signals with the patient being still, lying in bed in hospitals, our proposed algorithm is intentionally designed for monitoring and classifying the patient's ECG signals in the free-living environment. The patients are equipped with wearable ambulatory devices the whole day, which facilitates the real-time heart attack detection. In ECG preprocessing, an integral-coefficient-band-stop (ICBS) filter is applied, which omits time-consuming floating-point computations. In addition, two-layered Hidden Markov Models (HMMs) are applied to achieve ECG feature extraction and classification. The periodic ECG waveforms are segmented into ISO intervals, P subwave, QRS complex and T subwave respectively in the first HMM layer where expert-annotation assisted Baum-Welch algorithm is utilized in HMM modeling. Then the corresponding interval features are selected and applied to categorize the ECG into normal type or abnormal type (PVC, APC) in the second HMM layer. For verifying the effectiveness of our algorithm on abnormal signal detection, we have developed an ECG body sensor network (BSN) platform, whereby real-time ECG signals are collected, transmitted, displayed and the corresponding classification outcomes are deduced and shown on the BSN screen.

  15. A Practical and Cheap Circuit for ECG Sensing and Heart Frequency Alarm

    NASA Astrophysics Data System (ADS)

    Aviña-Cervantes, J. G.; González-García, A. E.; Alvarado-Méndez, E.; Trejo-Durán, M.; Torres-Cisneros, M.; Sánchez-Yáñez, R.; Ayala-Ramírez, V.

    2006-09-01

    A practical electronic circuit for ECG sensing, using high gain instrumentation amplifiers, a PIC microcontroller and two electrodes is presented. It allows to identify and to amplify a well-delimited ECG signal for a further wave analysis, and using a zero crossing detector a heart frequency detector is also implemented. By the moment, the conventional electrocardiogram (ECG) configurations making use of separate electrical connections to the arms and legs (bipolar limb lead 1) is exploited. This device is a practical and cheap way to monitoring ECG signal and some heart anomalies (e.g., arrhythmias, tachycardia) that can be used in a network to communicate anytime with a far health supervisor.

  16. A Study on the Optimal Positions of ECG Electrodes in a Garment for the Design of ECG-Monitoring Clothing for Male.

    PubMed

    Cho, Hakyung; Lee, Joo Hyeon

    2015-09-01

    Smart clothing is a sort of wearable device used for ubiquitous health monitoring. It provides comfort and efficiency in vital sign measurements and has been studied and developed in various types of monitoring platforms such as T-shirt and sports bra. However, despite these previous approaches, smart clothing for electrocardiography (ECG) monitoring has encountered a serious shortcoming relevant to motion artifacts caused by wearer movement. In effect, motion artifacts are one of the major problems in practical implementation of most wearable health-monitoring devices. In the ECG measurements collected by a garment, motion artifacts are usually caused by improper location of the electrode, leading to lack of contact between the electrode and skin with body motion. The aim of this study was to suggest a design for ECG-monitoring clothing contributing to reduction of motion artifacts. Based on the clothing science theory, it was assumed in this study that the stability of the electrode in a dynamic state differed depending on the electrode location in an ECG-monitoring garment. Founded on this assumption, effects of 56 electrode positions were determined by sectioning the surface of the garment into grids with 6 cm intervals in the front and back of the bodice. In order to determine the optimal locations of the ECG electrodes from the 56 positions, ECG measurements were collected from 10 participants at every electrode position in the garment while the wearer was in motion. The electrode locations indicating both an ECG measurement rate higher than 80.0 % and a large amplitude during motion were selected as the optimal electrode locations. The results of this analysis show four electrode locations with consistently higher ECG measurement rates and larger amplitudes amongst the 56 locations. These four locations were abstracted to be least affected by wearer movement in this research. Based on this result, a design of the garment-formed ECG monitoring platform

  17. UV254 absorbance as real-time monitoring and control parameter for micropollutant removal in advanced wastewater treatment with powdered activated carbon.

    PubMed

    Altmann, Johannes; Massa, Lukas; Sperlich, Alexander; Gnirss, Regina; Jekel, Martin

    2016-05-01

    This study investigates the applicability of UV absorbance measurements at 254 nm (UVA254) to serve as a simple and reliable surrogate parameter to monitor and control the removal of organic micropollutants (OMPs) in advanced wastewater treatment applying powdered activated carbon (PAC). Correlations between OMP removal and corresponding UVA254 reduction were determined in lab-scale adsorption batch tests and successfully applied to a pilot-scale PAC treatment stage to predict OMP removals in aggregate samples with good accuracy. Real-time UVA254 measurements were utilized to evaluate adapted PAC dosing strategies and proved to be effective for online monitoring of OMP removal. Furthermore, active PAC dosing control according to differential UVA254 measurements was implemented and tested. While precise removal predictions based on real-time measurements were not accurate for all OMPs, UVA254-controlled dynamic PAC dosing was capable of achieving stable OMP removals. UVA254 can serve as an effective surrogate parameter for OMP removal in technical PAC applications. Even though the applicability as control parameter to adjust PAC dosing to water quality changes might be limited to applications with fast response between PAC adjustment and adsorptive removal (e.g. direct filtration), UVA254 measurements can also be used to monitor the adsorption efficiency in more complex PAC applications.

  18. Real–Time ECG Algorithms for Ambulatory Patient Monitoring

    PubMed Central

    Pino, Esteban; Ohno–Machado, Lucila; Wiechmann, Eduardo; Curtis, Dorothy

    2005-01-01

    Brigham & Women’s Hospital is designing a wireless monitoring system for patients in the waiting area of the Emergency Department. A real–time ECG algorithm is required to monitor and alert changes in patients that have not yet been admitted to the Emergency Room. For this purpose, three simple algorithms are compared in terms of processing time, beat detection accuracy and heart rate (HR) estimation. Varying amounts of noise were added to records from the MIT-BIH Arrhythmia Database [1] to mimic expected waiting room conditions. Some recommendations regarding selection of an algorithm and further processing of HR series are presented. PMID:16779111

  19. Effect of intravenous zoledronic acid infusion on electrocardiographic parameters in patients with osteoporosis.

    PubMed

    Aktas, I; Nazikoglu, C; Kepez, A; Ozkan, F U; Kaysin, M Y; Akpinar, P; Dogan, Z; Ileri, C; Saymaz, S; Erdogan, O

    2016-12-01

    We evaluated the effects of zoledronic acid (ZA) therapy on electrocardiographic (ECG) parameters for the first time in the literature. Measurements were performed on ECGs obtained before and after ZA infusion on the same day as well as 1 month after the infusion. ZA infusion did not have any short- or long-term effect on any parameter that might be associated with the tendency for atrial fibrillation or ventricular arrhythmias.

  20. A novel, fully implantable, multichannel biotelemetry system for measurement of blood flow, pressure, ECG, and temperature.

    PubMed

    Axelsson, M; Dang, Q; Pitsillides, K; Munns, S; Hicks, J; Kassab, G S

    2007-03-01

    Biotelemetry provides high-quality data in awake, free-ranging animals without the effects of anesthesia and surgery. Although many biological parameters can be measured using biotelemetry, simultaneous telemetric measurements of pressure and flow have not been available. The objective of this study was to evaluate simultaneous measurements of blood flow, pressure, ECG, and temperature in a fully implantable system. This novel system allows the measurement of up to four channels of blood flow, up to three channels of pressure, and a single channel each of ECG and temperature. The system includes a bidirectional radio-frequency link that allows the implant to send data and accept commands to perform various tasks. The system is controlled by a base station decoder/controller that decodes the data stream sent by the implant into analog signals. The system also converts the data into a digital data stream that can be sent via ethernet to a remote computer for storage and/or analysis. The system was chronically implanted in swine and alligators for up to 5 wk. Both bench and in vivo animal tests were performed to evaluate system performance. Results show that this biotelemetry system is capable of long-term accurate monitoring of simultaneous blood flow and pressure. The system allows, within the room, recordings, since the implant transmission range is between 6 and 10 m, and, with a relay, backpack transmission distance of up to 500 m can be achieved. This system will have significant utility in chronic models of cardiovascular physiology and pathology.

  1. An XML based middleware for ECG format conversion.

    PubMed

    Li, Xuchen; Vojisavljevic, Vuk; Fang, Qiang

    2009-01-01

    With the rapid development of information and communication technologies, various e-health solutions have been proposed. The digitized medical images as well as the mono-dimension medical signals are two major forms of medical information that are stored and manipulated within an electronic medical environment. Though a variety of industrial and international standards such as DICOM and HL7 have been proposed, many proprietary formats are still pervasively used by many Hospital Information System (HIS) and Picture Archiving and Communication System (PACS) vendors. Those proprietary formats are the big hurdle to form a nationwide or even worldwide e-health network. Thus there is an imperative need to solve the medical data integration problem. Moreover, many small clinics, many hospitals in developing countries and some regional hospitals in developed countries, which have limited budget, have been shunned from embracing the latest medical information technologies due to their high costs. In this paper, we propose an XML based middleware which acts as a translation engine to seamlessly integrate clinical ECG data from a variety of proprietary data formats. Furthermore, this ECG translation engine is designed in a way that it can be integrated into an existing PACS to provide a low cost medical information integration and storage solution.

  2. A Mobile Device System for Early Warning of ECG Anomalies

    PubMed Central

    Szczepański, Adam; Saeed, Khalid

    2014-01-01

    With the rapid increase in computational power of mobile devices the amount of ambient intelligence-based smart environment systems has increased greatly in recent years. A proposition of such a solution is described in this paper, namely real time monitoring of an electrocardiogram (ECG) signal during everyday activities for identification of life threatening situations. The paper, being both research and review, describes previous work of the authors, current state of the art in the context of the authors' work and the proposed aforementioned system. Although parts of the solution were described in earlier publications of the authors, the whole concept is presented completely for the first time along with the prototype implementation on mobile device—a Windows 8 tablet with Modern UI. The system has three main purposes. The first goal is the detection of sudden rapid cardiac malfunctions and informing the people in the patient's surroundings, family and friends and the nearest emergency station about the deteriorating health of the monitored person. The second goal is a monitoring of ECG signals under non-clinical conditions to detect anomalies that are typically not found during diagnostic tests. The third goal is to register and analyze repeatable, long-term disturbances in the regular signal and finding their patterns. PMID:24955946

  3. Ubiquitous wireless ECG recording: a powerful tool physicians should embrace.

    PubMed

    Saxon, Leslie A

    2013-04-01

    The use of smart phones has increased dramatically and there are nearly a billion users on 3G and 4G networks worldwide. Nearly 60% of the U.S. population uses smart phones to access the internet, and smart phone sales now surpass those of desktop and laptop computers. The speed of wireless communication technology on 3G and 4G networks and the widespread adoption and use of iOS equipped smart phones (Apple Inc., Cupertino, CA, USA) provide infrastructure for the transmission of wireless biomedical data, including ECG data. These technologies provide an unprecedented opportunity for physicians to continually access data that can be used to detect issues before symptoms occur or to have definitive data when symptoms are present. The technology also greatly empowers and enables the possibility for unprecedented patient participation in their own medical education and health status as well as that of their social network. As patient advocates, physicians and particularly cardiac electrophysiologists should embrace the future and promise of wireless ECG recording, a technology solution that can truly scale across the global population.

  4. Effects of fluorocarbon propellants on respiratory flow and ECG.

    PubMed Central

    Valić, F; Skurić, Z; Bantić, Z; Rudar, M; Hećej, M

    1977-01-01

    Ten subjects were exposed to the propellants freon 11, freon 12, freon 114, to two mixtures of freon 11 and 12 and to a mixture of freon 12 and 114. The length of exposure was 15, 45 or 60 seconds. Maximum expiratory flow-volume (MEF) curves and ECG were recorded before, and intermittently up to 1 hour after, exposure. Breathing level concentrations of propellants during exposure were determined by gas chromatography. All freons induced biphasic reduction of ventilatory capacity on inhalation. The first fall occurred within a few minutes of exposure while the second was delayed 13-30 minutes after exposure. The effects of mixtures were greater than those of individual freons. The relative fall in MEF 75% was more pronounced than that in MEF 50%. No clear-cut pathological changes in ECG were found. Nevertheless, most subjects developed variations in heart rate exceeding those noted before exposure. In a few cases inversion of the T wave, and in one case atrioventricular block, were observed. PMID:871444

  5. Diagnosing Stroke in Acute Vertigo: The HINTS Family of Eye Movement Tests and the Future of the "Eye ECG".

    PubMed

    Newman-Toker, David E; Curthoys, Ian S; Halmagyi, G Michael

    2015-10-01

    Patients who present to the emergency department with symptoms of acute vertigo or dizziness are frequently misdiagnosed. Missed opportunities to promptly treat dangerous strokes can result in poor clinical outcomes. Inappropriate testing and incorrect treatments for those with benign peripheral vestibular disorders leads to patient harm and unnecessary costs. Over the past decade, novel bedside approaches to diagnose patients with the acute vestibular syndrome have been developed and refined. A battery of three bedside tests of ocular motor physiology known as "HINTS" (head impulse, nystagmus, test of skew) has been shown to identify acute strokes more accurately than even magnetic resonance imaging with diffusion-weighted imaging (MRI-DWI) when applied in the early acute period by eye-movement specialists. Recent advances in lightweight, high-speed video-oculography (VOG) technology have made possible a future in which HINTS might be applied by nonspecialists in frontline care settings using portable VOG. Use of technology to measure eye movements (VOG-HINTS) to diagnose stroke in the acute vestibular syndrome is analogous to the use of electrocardiography (ECG) to diagnose myocardial infarction in acute chest pain. This "eye ECG" approach could transform care for patients with acute vertigo and dizziness around the world. In the United States alone, successful implementation would likely result in improved quality of emergency care for hundreds of thousands of peripheral vestibular patients and tens of thousands of stroke patients, as well as an estimated national health care savings of roughly $1 billion per year. In this article, the authors review the origins of the HINTS approach, empiric evidence and pathophysiologic principles supporting its use, and possible uses for the eye ECG in teleconsultation, teaching, and triage.

  6. Application of Lead Field Theory and Computerized Thorax Modeling for the ECG Inverse Problem

    DTIC Science & Technology

    2007-11-02

    Takano, P. Laarne, J. Malmivuo Ragnar Granit Institute, Tampere University of Technology, Finland Abstract – The ECG inverse problem is a...Performing Organization Name(s) and Address(es) Ragnar Granit Institute, Tampere University of Technology, Finland Performing Organization Report Number...computational load for calculating ECG inverse solutions. ACKNOWLEDGMENTS This work has been kindly supported by The Ragnar Granit Foundation, The

  7. Effects of electrocardiography contamination and comparison of ECG removal methods on upper trapezius electromyography recordings.

    PubMed

    Marker, Ryan J; Maluf, Katrina S

    2014-12-01

    Electromyography (EMG) recordings from the trapezius are often contaminated by the electrocardiography (ECG) signal, making it difficult to distinguish low-level muscle activity from muscular rest. This study investigates the influence of ECG contamination on EMG amplitude and frequency estimations in the upper trapezius during muscular rest and low-level contractions. A new method of ECG contamination removal, filtered template subtraction (FTS), is described and compared to 30 Hz high-pass filter (HPF) and averaged template subtraction (ATS) methods. FTS creates a unique template of each ECG artifact using a low-pass filtered copy of the contaminated signal, which is subtracted from contaminated periods in the original signal. ECG contamination results in an over-estimation of EMG amplitude during rest in the upper trapezius, with negligible effects on amplitude and frequency estimations during low-intensity isometric contractions. FTS and HPF successfully removed ECG contamination from periods of muscular rest, yet introduced errors during muscle contraction. Conversely, ATS failed to fully remove ECG contamination during muscular rest, yet did not introduce errors during muscle contraction. The relative advantages and disadvantages of different ECG contamination removal methods should be considered in the context of the specific motor tasks that require analysis.

  8. Interactive Videoconference Supported Teaching in Undergraduate Nursing: A Case Study for ECG

    ERIC Educational Resources Information Center

    Celikkan, Ufuk; Senuzun, Fisun; Sari, Dilek; Sahin, Yasar Guneri

    2013-01-01

    This paper describes how interactive videoconference can benefit the Electrocardiography (ECG) skills of undergraduate nursing students. We have implemented a learning system that interactively transfers the visual and practical aspects of ECG from a nursing skills lab into a classroom where the theoretical part of the course is taught. The…

  9. Anomaly Detection using Multi-channel FLAC for Supporting Diagnosis of ECG

    NASA Astrophysics Data System (ADS)

    Ye, Jiaxing; Kobayashi, Takumi; Murakawa, Masahiro; Higuchi, Tetsuya; Otsu, Nobuyuki

    In this paper, we propose an approach for abnormality detection in multi-channel ECG signals. This system serves as front end to detect the irregular sections in ECG signals, where symptoms may be observed. Thereby, the doctor can focus on only the detected suspected symptom sections, ignoring the disease-free parts. Hence the workload of the inspection by the doctors is significantly reduced and the diagnosis efficiency can be sharply improved. For extracting the predominant characteristics of multi-channel ECG signals, we propose multi-channel Fourier local auto-correlations (m-FLAC) features on multi-channel complex spectrograms. The method characterizes the amplitude and phase information as well as temporal dynamics of the multi-channel ECG signal. At the anomaly detection stage, we employ complex subspace method for statistically modeling the normal (healthy) ECG patterns as in one-class learning. Then, we investigate the input ECG signals by measuring its deviation distance to the trained subspace. The ECG sections with disordered spectral distributions can be effectively discerned based on such distance metric. To validate the proposed approach, we conducted experiments on ECG dataset. The experimental results demonstrated the effectiveness of the proposed approach including promising performance and high efficiency, compared to conventional methods.

  10. Interoperability in digital electrocardiography: harmonization of ISO/IEEE x73-PHD and SCP-ECG.

    PubMed

    Trigo, Jesús D; Chiarugi, Franco; Alesanco, Alvaro; Martínez-Espronceda, Miguel; Serrano, Luis; Chronaki, Catherine E; Escayola, Javier; Martínez, Ignacio; García, José

    2010-11-01

    The ISO/IEEE 11073 (x73) family of standards is a reference frame for medical device interoperability. A draft for an ECG device specialization (ISO/IEEE 11073-10406-d02) has already been presented to the Personal Health Device (PHD) Working Group, and the Standard Communications Protocol for Computer-Assisted ElectroCardioGraphy (SCP-ECG) Standard for short-term diagnostic ECGs (EN1064:2005+A1:2007) has recently been approved as part of the x73 family (ISO 11073-91064:2009). These factors suggest the coordinated use of these two standards in foreseeable telecardiology environments, and hence the need to harmonize them. Such harmonization is the subject of this paper. Thus, a mapping of the mandatory attributes defined in the second draft of the ISO/IEEE 11073-10406-d02 and the minimum SCP-ECG fields is presented, and various other capabilities of the SCP-ECG Standard (such as the messaging part) are also analyzed from an x73-PHD point of view. As a result, this paper addresses and analyzes the implications of some inconsistencies in the coordinated use of these two standards. Finally, a proof-of-concept implementation of the draft x73-PHD ECG device specialization is presented, along with the conversion from x73-PHD to SCP-ECG. This paper, therefore, provides recommendations for future implementations of telecardiology systems that are compliant with both x73-PHD and SCP-ECG.

  11. Simple electrocardiogram (ECG) signal analyzer for homecare system among the elderly.

    PubMed

    Lin, Liuh-Chii; Yeh, Yun-Chi; Ho, Kuei-Jung

    2015-09-10

    This study presents a simple electrocardiogram (ECG) signal analyzer for homecare system among the elderly. It can transmit ECG signals of patient around his/her house through Bluetooth to computers in house. ECG signals are analyzed by the computer. If abnormal case of heartbeat is found, the emergency call is automatically dialed. Meanwhile, the determined heartbeat case of ECG signals will be forwarded to patient's MD through internet. Therefore, the patient can do whatever he/she wants around his/her house with our proposed simple cardiac arrhythmias signal analyzer. The proposed consists of five major processing stages: (i) preprocessing stage for enlarging ECG signals' amplitude and eliminating noises; (ii) ECG signal transmitter/receiver stage, ECG signals are transmitted through Bluetooth to the signal receiver in patient's house; (iii) QRS extraction stage for detecting QRS waveform using the Difference Operation Method (DOM) method; (iv) qualitative features stage for qualitative feature selection on ECG signals; and (v) classification stage for determining patient's heartbeat cases using the Principal Component Analysis (PCA) method. In the experiment, the total classification accuracy (TCA) was approximately 93.19% in average.

  12. Simple electrocardiogram (ECG) signal analyzer for homecare system among the elderly.

    PubMed

    Lin, Liuh-Chii; Yeh, Yun-Chi; Ho, Kuei-Jung

    2015-01-01

    This study presents a simple electrocardiogram (ECG) signal analyzer for homecare system among the elderly. It can transmit ECG signals of patient around his/her house through Bluetooth to computers in house. ECG signals are analyzed by the computer. If abnormal case of heartbeat is found, the emergency call is automatically dialed. Meanwhile, the determined heartbeat case of ECG signals will be forwarded to patient's MD through internet. Therefore, the patient can do whatever he/she wants around his/her house with our proposed simple cardiac arrhythmias signal analyzer. The proposed consists of five major processing stages: (i) preprocessing stage for enlarging ECG signals' amplitude and eliminating noises; (ii) ECG signal transmitter/receiver stage, ECG signals are transmitted through Bluetooth to the signal receiver in patient's house; (iii) QRS extraction stage for detecting QRS waveform using the Difference Operation Method (DOM) method; (iv) qualitative features stage for qualitative feature selection on ECG signals; and (v) classification stage for determining patient's heartbeat cases using the Principal Component Analysis (PCA) method. In the experiment, the total classification accuracy (TCA) was approximately 93.19% in average.

  13. A review on digital ECG formats and the relationships between them.

    PubMed

    Trigo, Jesús Daniel; Alesanco, Alvaro; Martínez, Ignacio; García, José

    2012-05-01

    A plethora of digital ECG formats have been proposed and implemented. This heterogeneity hinders the design and development of interoperable systems and entails critical integration issues for the healthcare information systems. This paper aims at performing a comprehensive overview on the current state of affairs of the interoperable exchange of digital ECG signals. This includes 1) a review on existing digital ECG formats, 2) a collection of applications and cardiology settings using such formats, 3) a compilation of the relationships between such formats, and 4) a reflection on the current situation and foreseeable future of the interoperable exchange of digital ECG signals. The objectives have been approached by completing and updating previous reviews on the topic through appropriate database mining. 39 digital ECG formats, 56 applications, tools or implantation experiences, 47 mappings/converters, and 6 relationships between such formats have been found in the literature. The creation and generalization of a single standardized ECG format is a desirable goal. However, this unification requires political commitment and international cooperation among different standardization bodies. Ongoing ontology-based approaches covering ECG domain have recently emerged as a promising alternative for reaching fully fledged ECG interoperability in the near future.

  14. Wavelet analysis and time-frequency distributions of the body surface ECG before and after angioplasty.

    PubMed

    Gramatikov, B; Brinker, J; Yi-chun, S; Thakor, N V

    2000-06-01

    In a pilot study, electrocardiographic (ECG) recordings of patients with left and right coronary stenosis taken before and after angioplasty were analyzed using the continuous wavelet transform. Time-frequency distributions were obtained for different leads in order to examine the dynamics of the QRS-spectrum and establish features specific of ischemia in the time-frequency domain. We found relevant changes in the mid-frequency range, reflecting the ECG's response to percutaneous transluminal coronary angioplasty (PTCA). The changes appeared in ECG leads close to ischemic zones of the myocardium. Time-frequency distributions of the ECG during the QRS may thus become another electrocardiographic indicator of ischemia, alternative to ST-level in standard ECG or body surface mapping. The paper demonstrates the ability of the continuous wavelet transform to detect short lasting events of low amplitude superimposed on large signal deflections.

  15. Relative Amplitude based Features of characteristic ECG-Peaks for Identification of Coronary Artery Disease

    NASA Astrophysics Data System (ADS)

    Gohel, Bakul; Tiwary, U. S.; Lahiri, T.

    Coronary artery disease or Myocardial Infarction is the leading cause of death and disability in the world. ECG is widely used as a cheap diagnostic tool for diagnosis of coronary artery disease but has low sensitivity with the present criteria based on ST-segment, T wave and Q wave changes. So to increase the sensitivity of the ECG we have introduced relative amplitude based new features of characteristic ‘R’ and ‘S’ ECG-peaks between two leads. Relative amplitude based features shows remarkable capability in discriminating Myocardial Infarction and Healthy pattern using backpropogation neural network classifier yield results with 81.82% sensitivity and 81.82% specificity. Also relative amplitude might be an efficient method in minimizing the effect of body composition on ECG amplitude based features without use of any information from other than ECG

  16. Performance of human body communication-based wearable ECG with capacitive coupling electrodes.

    PubMed

    Sakuma, Jun; Anzai, Daisuke; Wang, Jianqing

    2016-09-01

    Wearable electrocardiogram (ECG) is attracting much attention in daily healthcare applications, and human body communication (HBC) technology provides an evident advantage in making the sensing electrodes of ECG also working for transmission through the human body. In view of actual usage in daily life, however, non-contact electrodes to the human body are desirable. In this Letter, the authors discussed the ECG circuit structure in the HBC-based wearable ECG for removing the common mode noise when employing non-contact capacitive coupling electrodes. Through the comparison of experimental results, they have shown that the authors' proposed circuit structure with the third electrode directly connected to signal ground can provide an effect on common mode noise reduction similar to the usual drive-right-leg circuit, and a sufficiently good acquisition performance of ECG signals.

  17. Left Ventricular Hypertrophy: An allometric comparative analysis of different ECG markers

    NASA Astrophysics Data System (ADS)

    Bonomini, M. P.; Ingallina, F.; Barone, V.; Valentinuzzi, M. E.; Arini, P. D.

    2011-12-01

    Allometry, in general biology, measures the relative growth of a part in relation to the whole living organism. Left ventricular hypertrophy (LVH) is the heart adaptation to excessive load (systolic or diastolic). The increase in left ventricular mass leads to an increase in the electrocardiographic voltages. Based on clinical data, we compared the allometric behavior of three different ECG markers of LVH. To do this, the allometric fit AECG = δ + β (VM) relating left ventricular mass (estimated from ecocardiographic data) and ECG amplitudes (expressed as the Cornell-Voltage, Sokolow and the ECG overall voltage indexes) were compared. Besides, sensitivity and specifity for each index were analyzed. The more sensitive the ECG criteria, the better the allometric fit. In conclusion: The allometric paradigm should be regarded as the way to design new and more sensitive ECG-based LVH markers.

  18. Utility of Electrocardiography (ECG)-Gated Computed Tomography (CT) for Preoperative Evaluations of Thymic Epithelial Tumors

    PubMed Central

    Ozawa, Yoshiyuki; Hara, Masaki; Nakagawa, Motoo; Shibamoto, Yuta

    2016-01-01

    Summary Background Preoperative evaluation of invasion to the adjacent organs is important for the thymic epithelial tumors on CT. The purpose of our study was to evaluate the utility of electrocardiography (ECG)-gated CT for assessing thymic epithelial tumors with regard to the motion artifacts produced and the preoperative diagnostic accuracy of the technique. Material/Methods Forty thymic epithelial tumors (36 thymomas and 4 thymic carcinomas) were examined with ECG-gated contrast-enhanced CT using a dual source scanner. The scan delay after the contrast media injection was 30 s for the non-ECG-gated CT and 100 s for the ECG-gated CT. Two radiologists blindly evaluated both the non-ECG-gated and ECG-gated CT images for motion artifacts and determined whether the tumors had invaded adjacent structures (mediastinal fat, superior vena cava, brachiocephalic veins, aorta, pulmonary artery, pericardium, or lungs) on each image. Motion artifacts were evaluated using a 3-grade scale. Surgical and pathological findings were used as a reference standard for tumor invasion. Results Motion artifacts were significantly reduced for all structures by ECG gating (p=0.0089 for the lungs and p<0.0001 for the other structures). Non-ECG-gated CT and ECG-gated CT demonstrated 79% and 95% accuracy, respectively, during assessments of pericardial invasion (p=0.03). Conclusions ECG-gated CT reduced the severity of motion artifacts and might be useful for preoperative assessment whether thymic epithelial tumors have invaded adjacent structures. PMID:27920842

  19. Personalized USB Biosensor Module for Effective ECG Monitoring.

    PubMed

    Sladojević, Srdjan; Arsenović, Marko; Lončar-Turukalo, Tatjana; Sladojević, Miroslava; Ćulibrk, Dubravko

    2016-01-01

    The burden of chronic disease and associated disability present a major threat to financial sustainability of healthcare delivery systems. The need for cost-effective early diagnosis and disease prevention is evident driving the development of personalized home health solutions. The proposed solution presents an easy to use ECG monitoring system. The core hardware component is a biosensor dongle with sensing probes at one end, and micro USB interface at the other end, offering reliable and unobtrusive sensing, preprocessing and storage. An additional component is a smart phone, providing both the biosensor's power supply and an intuitive user application for the real-time data reading. The system usage is simplified, with innovative solutions offering plug and play functionality avoiding additional driver installation. Personalized needs could be met with different sensor combinations enabling adequate monitoring in chronic disease, during physical activity and in the rehabilitation process.

  20. Ambulatory measurement of the ECG T-wave amplitude.

    PubMed

    van Lien, René; Neijts, Melanie; Willemsen, Gonneke; de Geus, Eco J C

    2015-02-01

    Ambulatory recording of the preejection period (PEP) can be used to measure changes in cardiac sympathetic nervous system (SNS) activity under naturalistic conditions. Here, we test the ECG T-wave amplitude (TWA) as an alternative measure, using 24-h ambulatory monitoring of PEP and TWA in a sample of 564 healthy adults. The TWA showed a decrease in response to mental stress and a monotonic decrease from nighttime sleep to daytime sitting and more physically active behaviors. Within-participant changes in TWA were correlated with changes in the PEP across the standardized stressors (r = .42) and the unstandardized naturalistic conditions (mean r = .35). Partialling out changes in heart rate and vagal effects attenuated these correlations, but they remained significant. Ambulatory TWA cannot replace PEP, but simultaneous recording of TWA and PEP provides a more comprehensive picture of changes in cardiac SNS activity in real-life settings.

  1. Usefulness of Derived Frank Lead Parameters in Screening for Coronary Artery Disease and Cardiomyopathy

    NASA Technical Reports Server (NTRS)

    DePalma, J. L.; Schlegel, T. T.; Arenare, B.; Greco, E. C.; Starc, V.; Rahman, M. A.; Delgado, R.

    2007-01-01

    We investigated the accuracy of several known as well as newly-introduced derived Frank-lead ECG parameters in differentiating healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. The following derived Frank lead parameters were studied for their accuracy in detecting CAD and CM: the spatial ventricular gradient (VG), including its beat-to-beat coefficient of variability (VG CV); the spatial mean QRS (SM-QRS) and T-waves (SM-T) and their beat-to-beat coefficients of variability; the spatial ventricular activation time (VAT); the mean and maximum spatial QRS-T angles; and standard late potentials parameters (RMS40, fQRSD and LAS). Several of these parameters were accurate in discriminating between the control group and both diseased groups at p less than 0.0001. For example the fQRSD, VG CV, mean spatial QRS-T angle and VG minus SM-QRS (which is similar to the SM-T) had retrospective areas under the ROC curve of 0.78, 0.78, 0.80, and 0.84 (CAD vs. controls) and 0.93, 0.88, 0.98 and 0.99 (CM vs. controls), respectively. The single most effective parameter in discriminating between the CAD and CM groups was the spatial VAT (44 plus or minus 5.8 vs. 53 plus or minus 9.9 ms, p less than 0.0001), with an area under the ROC curve of 0.80. Since subsequent prospective analyses using new groups of patients and healthy subjects have yielded only slightly less accurate results, we conclude that derived Frank-lead parameters show great promise for potentially contributing to the development of a rapid and inexpensive resting ECG-based screening test for heart disease.

  2. ECG findings after myocardial infarction in children after Kawasaki disease

    SciTech Connect

    Nakanishi, T.; Takao, A.; Kondoh, C.; Nakazawa, M.; Hiroe, M.; Matsumoto, Y.

    1988-10-01

    Standard 12-lead ECGs were evaluated in 17 children with myocardial infarction and 78 children without myocardial infarction after Kawasaki disease; sensitivity and specificity of the ECG infarction criteria were determined. The presence or absence of myocardial infarction was determined from either clinical examination results (coronary angiography, ventriculography, and thallium-201 myocardial imaging) or autopsy findings. Of seven patients with inferior infarction, abnormally deep Q waves in lead II, III, or aVF were observed in six, but the duration was greater than 0.04 second in only one (14%). The sensitivity and specificity of inferior infarction criteria based on Q wave amplitude were 86% and 97%, respectively. Of eight patients with anterior infarction, seven (88%) had abnormally deep and wide (greater than or equal to 0.04 second) Q waves in anterior chest leads. The sensitivity and specificity of the infarction criteria based on the amplitude and duration of the Q wave were 75% and 99%, respectively. Of seven patients with lateral infarction, Q waves were observed in lead I, aVL, or both in four patients, and in all of these patients Q waves were wider than 0.04 second. In two patients with both inferior and anterior infarction, Q waves were observed only in leads II, III, and aVF; in only one patient were the Q waves wider than 0.04 second. Thus deep Q waves in lead II, III, or aVF that are not wider than 0.04 second may indicate inferior infarction in children. Q waves in lead I, aVL, and chest leads associated with anterolateral infarction are in most instances deep and wide.

  3. Dry Electrodes for ECG and Pulse Transit Time for Blood Pressure: A Wearable Sensor and Smartphone Communication Approach

    NASA Astrophysics Data System (ADS)

    Shyamkumar, Prashanth

    Cardiovascular Diseases (CVDs) have been a major cause for deaths in both men and women in United States. Cerebrovascular Diseases like Strokes are known to have origins in CVDs as well. Moreover, nearly 18 Million Americans have a history of myocardial infarction and are currently undergoing cardiac rehabilitation. Consequently, CVDs are the highest costing disease groups and cost more than all types of cancer combined. However, significant cost reduction is possible through the effective use of the vast advances in embedded and pervasive electronic devices for healthcare. These devices can automate and move a significant portion of disease management to the patient's home through cyber connectivity, a concept known as point-of-care (POC) diagnostics and healthcare services. POC can minimize hospital visits and potentially avoid admission altogether with prognostic tools that give advanced notice of any abnormalities or chronic illnesses so that the treatment can be planned in advance. The POC concept requires continuous remote health monitoring. Therefore, the various sensors needed for comprehensive monitoring need to be worn daily and throughout the day. Moreover, true "roaming" capability is necessary so that it does not restrict the user's travel or his/her quotidian activities. Two biomedical signals namely, Electrocardiogram (ECG) and Blood Pressure are important diagnostic tests in assessing the cardiac health of a person. To that end, the research presented in this thesis: First , describes the development of a remote monitoring solution based on Bluetooth(TM), smartphones and cyber infrastructure for cardiac care called e-nanoflex. Second, Sensors for ECG that are compatible with everyday life style namely, (a) dry, gel-less vertically aligned gold nanowire electrodes, (b) dry textile-based conductive sensor electrodes to address the need for this technology to monitor cardiovascular diseases in women are tested with e-nanoflex and discussed. Third, non

  4. Unsupervised learning applied in MER and ECG signals through Gaussians mixtures with the Expectation-Maximization algorithm and Variational Bayesian Inference.

    PubMed

    Vargas Cardona, Hernán Darío; Orozco, Álvaro Ángel; Álvarez, Mauricio A

    2013-01-01

    Automatic identification of biosignals is one of the more studied fields in biomedical engineering. In this paper, we present an approach for the unsupervised recognition of biomedical signals: Microelectrode Recordings (MER) and Electrocardiography signals (ECG). The unsupervised learning is based in classic and bayesian estimation theory. We employ gaussian mixtures models with two estimation methods. The first is derived from the frequentist estimation theory, known as Expectation-Maximization (EM) algorithm. The second is obtained from bayesian probabilistic estimation and it is called variational inference. In this framework, both methods are used for parameters estimation of Gaussian mixtures. The mixtures models are used for unsupervised pattern classification, through the responsibility matrix. The algorithms are applied in two real databases acquired in Parkinson's disease surgeries and electrocardiograms. The results show an accuracy over 85% in MER and 90% in ECG for identification of two classes. These results are statistically equal or even better than parametric (Naive Bayes) and nonparametric classifiers (K-nearest neighbor).

  5. Bivariable analysis of ventricular late potentials in high resolution ECG records

    NASA Astrophysics Data System (ADS)

    Orosco, L.; Laciar, E.

    2007-11-01

    In this study the bivariable analysis for ventricular late potentials detection in high-resolution electrocardiographic records is proposed. The standard time-domain analysis and the application of the time-frequency technique to high-resolution ECG records are briefly described as well as their corresponding results. In the proposed technique the time-domain parameter, QRSD and the most significant time-frequency index, ENQRS are used like variables. A bivariable index is defined, that combines the previous parameters. The propose technique allows evaluating the risk of ventricular tachycardia in post-myocardial infarct patients. The results show that the used bivariable index allows discriminating between the patient's population with ventricular tachycardia and the subjects of the control group. Also, it was found that the bivariable technique obtains a good valuation as diagnostic test. It is concluded that comparatively, the valuation of the bivariable technique as diagnostic test is superior to that of the time-domain method and the time-frequency technique evaluated individually.

  6. Parameters of Stromal Activation and Epithelial to Mesenchymal Transition as Predictive Biomarkers for Induction Chemotherapy in Patients With Locally Advanced Oral Cavity and Oropharyngeal Squamous Cell Cancer

    PubMed Central

    Geweiler, Jana; Inhestern, Johanna; Berndt, Alexander; Guntinas-Lichius, Orlando

    2016-01-01

    Objectives Induction chemotherapy (IC) is likely to be effective for biologically distinct subgroups of oral cancer and biomarker development may lead to identification of those patients. Methods We evaluated immune cell infiltration, stroma formation and structure of the invasive front as well as the immunohistochemical expression of alpha smooth muscle actin (ASMA), CD163, E-cadherin, N-cadherin, and the laminin gamma 2 chain in pretreatment biopsy specimens and surgical resections after IC in 20 patients with locally advanced oral cancer who were treated in a prospective, ongoing, phase II trial on IC using docetaxel, cisplatin, and 5-fluorouracil (TPF). Results Significant negative prognostic factors for incomplete pathological tumor response to IC were alcohol abuse (P=0.032), cN+ (P=0.042), and <30% tumor reduction after first cycle of IC (P=0.034). Of the investigated histological parameters and biomarkers only a low membrane-bound expression of E-cadherin showed a trend to be associated with incomplete response to IC (P=0.061). Low expression of ASMA in stromal vessels and a strong tumor invasion front were significantly associated to tumor recurrence (P=0.024 and P=0.004, respectively). The median follow-up of all patients was 35 months. Alcohol abuse (P<0.001), <30% tumor reduction after first cycle of IC (P=0.005), and a strong tumor invasion front (P=0.019) were negative prognostic factors for overall survival. Conclusion A strong predictive biomarker among the investigated parameters for benefitting from TPF IC could not be found. The extent of the tumor invasion front was a negative prognostic marker for recurrence and survival in oral cancer treated by TPF IC followed by surgery and postoperative radiochemotherapy. PMID:27416733

  7. Classification of a Driver's cognitive workload levels using artificial neural network on ECG signals.

    PubMed

    Tjolleng, Amir; Jung, Kihyo; Hong, Wongi; Lee, Wonsup; Lee, Baekhee; You, Heecheon; Son, Joonwoo; Park, Seikwon

    2017-03-01

    An artificial neural network (ANN) model was developed in the present study to classify the level of a driver's cognitive workload based on electrocardiography (ECG). ECG signals were measured on 15 male participants while they performed a simulated driving task as a primary task with/without an N-back task as a secondary task. Three time-domain ECG measures (mean inter-beat interval (IBI), standard deviation of IBIs, and root mean squared difference of adjacent IBIs) and three frequencydomain ECG measures (power in low frequency, power in high frequency, and ratio of power in low and high frequencies) were calculated. To compensate for individual differences in heart response during the driving tasks, a three-step data processing procedure was performed to ECG signals of each participant: (1) selection of two most sensitive ECG measures, (2) definition of three (low, medium, and high) cognitive workload levels, and (3) normalization of the selected ECG measures. An ANN model was constructed using a feed-forward network and scaled conjugate gradient as a back-propagation learning rule. The accuracy of the ANN classification model was found satisfactory for learning data (95%) and testing data (82%).

  8. A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition.

    PubMed

    Fong, Ee-May; Chung, Wan-Young

    2015-08-05

    A capacitive electrocardiography (cECG) technique using a non-invasive ECG measuring technology that does not require direct contact between the sensor and the skin has attracted much interest. The system encounters several challenges when the sensor electrode and subject's skin are weakly coupled. Because there is no direct physical contact between the subject and any grounding point, there is no discharge path for the built-up electrostatic charge. Subsequently, the electrostatic charge build-up can temporarily contaminate the ECG signal from being clearly visible; a stabilization period (3-15 min) is required for the measurement of a clean, stable ECG signal at low humidity levels (below 55% relative humidity). Therefore, to obtain a clear ECG signal without noise and to reduce the ECG signal stabilization time to within 2 min in a dry ambient environment, we have developed a fabric electrode with embedded polymer (FEEP). The designed hygroscopic FEEP has an embedded superabsorbent polymer layer. The principle of FEEP as a conductive electrode is to provide humidity to the capacitive coupling to ensure strong coupling and to allow for the measurement of a stable, clear biomedical signal. The evaluation results show that hygroscopic FEEP is capable of rapidly measuring high-accuracy ECG signals with a higher SNR ratio.

  9. An IoT-cloud Based Wearable ECG Monitoring System for Smart Healthcare.

    PubMed

    Yang, Zhe; Zhou, Qihao; Lei, Lei; Zheng, Kan; Xiang, Wei

    2016-12-01

    Public healthcare has been paid an increasing attention given the exponential growth human population and medical expenses. It is well known that an effective health monitoring system can detect abnormalities of health conditions in time and make diagnoses according to the gleaned data. As a vital approach to diagnose heart diseases, ECG monitoring is widely studied and applied. However, nearly all existing portable ECG monitoring systems cannot work without a mobile application, which is responsible for data collection and display. In this paper, we propose a new method for ECG monitoring based on Internet-of-Things (IoT) techniques. ECG data are gathered using a wearable monitoring node and are transmitted directly to the IoT cloud using Wi-Fi. Both the HTTP and MQTT protocols are employed in the IoT cloud in order to provide visual and timely ECG data to users. Nearly all smart terminals with a web browser can acquire ECG data conveniently, which has greatly alleviated the cross-platform issue. Experiments are carried out on healthy volunteers in order to verify the reliability of the entire system. Experimental results reveal that the proposed system is reliable in collecting and displaying real-time ECG data, which can aid in the primary diagnosis of certain heart diseases.

  10. A low-power portable ECG sensor interface with dry electrodes

    NASA Astrophysics Data System (ADS)

    Xiaofei, Pu; Lei, Wan; Hui, Zhang; Yajie, Qin; Zhiliang, Hong

    2013-05-01

    This paper describes a low-power portable sensor interface dedicated to sensing and processing electrocardiogram (ECG) signals. Dry electrodes were employed in this ECG sensor, which eliminates the need of conductive gel and avoids complicated and mandatory skin preparation before electrode attachment. This ECG sensor system consists of two ICs, an analog front-end (AFE) and a successive approximation register analog-to-digital converter (SAR ADC) containing a relaxation oscillator. This proposed design was fabricated in a 0.18 μm 1P6M standard CMOS process. The AFE for extracting the biopotential signals is essential in this ECG sensor. In measurements, the AFE obtains a mid-band gain of 45 dB, a bandwidth from 0.6 to 160 Hz, and a total input referred noise of 2.8 μV rms while consuming 1 μW from the 1.8 V supply. The noise efficiency factor (NEF) of our design is 3.4. After conditioning, the amplified ECG signal is digitized by a 12-bit SAR ADC with 61.8 dB SNDR and 220 fJ/conversion-step. Finally, a complete ECG sensor interface with three dry copper electrodes is demonstrated in real-word setting, showing successful recordings of a capture ECG waveform.

  11. An Investigation on the Effect of Extremely Low Frequency Pulsed Electromagnetic Fields on Human Electrocardiograms (ECGs)

    PubMed Central

    Fang, Qiang; Mahmoud, Seedahmed S.; Yan, Jiayong; Li, Hui

    2016-01-01

    For this investigation, we studied the effects of extremely low frequency pulse electromagnetic fields (ELF-PEMF) on the human cardiac signal. Electrocardiograms (ECGs) of 22 healthy volunteers before and after a short duration of ELF-PEMF exposure were recorded. The experiment was conducted under single-blind conditions. The root mean square (RMS) value of the recorded data was considered as comparison criteria. We also measured and analysed four important ECG time intervals before and after ELF-PEMF exposure. Results revealed that the RMS value of the ECG recordings from 18 participants (81.8% of the total participants) increased with a mean value of 3.72%. The increase in ECG voltage levels was then verified by a second experimental protocol with a control exposure. In addition to this, we used hyperbolic T-distributions (HTD) in the analysis of ECG signals to verify the change in the RR interval. It was found that there were small shifts in the frequency-domain signal before and after EMF exposure. This shift has an influence on all frequency components of the ECG signals, as all spectrums were shifted. It is shown from this investigation that a short time exposure to ELF-PEMF can affect the properties of ECG signals. Further study is needed to consolidate this finding and discover more on the biological effects of ELF-PEMF on human physiological processes. PMID:27886102

  12. Compressed sensing for real-time energy-efficient ECG compression on wireless body sensor nodes.

    PubMed

    Mamaghanian, Hossein; Khaled, Nadia; Atienza, David; Vandergheynst, Pierre

    2011-09-01

    Wireless body sensor networks (WBSN) hold the promise to be a key enabling information and communications technology for next-generation patient-centric telecardiology or mobile cardiology solutions. Through enabling continuous remote cardiac monitoring, they have the potential to achieve improved personalization and quality of care, increased ability of prevention and early diagnosis, and enhanced patient autonomy, mobility, and safety. However, state-of-the-art WBSN-enabled ECG monitors still fall short of the required functionality, miniaturization, and energy efficiency. Among others, energy efficiency can be improved through embedded ECG compression, in order to reduce airtime over energy-hungry wireless links. In this paper, we quantify the potential of the emerging compressed sensing (CS) signal acquisition/compression paradigm for low-complexity energy-efficient ECG compression on the state-of-the-art Shimmer WBSN mote. Interestingly, our results show that CS represents a competitive alternative to state-of-the-art digital wavelet transform (DWT)-based ECG compression solutions in the context of WBSN-based ECG monitoring systems. More specifically, while expectedly exhibiting inferior compression performance than its DWT-based counterpart for a given reconstructed signal quality, its substantially lower complexity and CPU execution time enables it to ultimately outperform DWT-based ECG compression in terms of overall energy efficiency. CS-based ECG compression is accordingly shown to achieve a 37.1% extension in node lifetime relative to its DWT-based counterpart for "good" reconstruction quality.

  13. A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition

    PubMed Central

    Fong, Ee-May; Chung, Wan-Young

    2015-01-01

    A capacitive electrocardiography (cECG) technique using a non-invasive ECG measuring technology that does not require direct contact between the sensor and the skin has attracted much interest. The system encounters several challenges when the sensor electrode and subject’s skin are weakly coupled. Because there is no direct physical contact between the subject and any grounding point, there is no discharge path for the built-up electrostatic charge. Subsequently, the electrostatic charge build-up can temporarily contaminate the ECG signal from being clearly visible; a stabilization period (3–15 min) is required for the measurement of a clean, stable ECG signal at low humidity levels (below 55% relative humidity). Therefore, to obtain a clear ECG signal without noise and to reduce the ECG signal stabilization time to within 2 min in a dry ambient environment, we have developed a fabric electrode with embedded polymer (FEEP). The designed hygroscopic FEEP has an embedded superabsorbent polymer layer. The principle of FEEP as a conductive electrode is to provide humidity to the capacitive coupling to ensure strong coupling and to allow for the measurement of a stable, clear biomedical signal. The evaluation results show that hygroscopic FEEP is capable of rapidly measuring high-accuracy ECG signals with a higher SNR ratio. PMID:26251913

  14. Low-power analog integrated circuits for wireless ECG acquisition systems.

    PubMed

    Tsai, Tsung-Heng; Hong, Jia-Hua; Wang, Liang-Hung; Lee, Shuenn-Yuh

    2012-09-01

    This paper presents low-power analog ICs for wireless ECG acquisition systems. Considering the power-efficient communication in the body sensor network, the required low-power analog ICs are developed for a healthcare system through miniaturization and system integration. To acquire the ECG signal, a low-power analog front-end system, including an ECG signal acquisition board, an on-chip low-pass filter, and an on-chip successive-approximation analog-to-digital converter for portable ECG detection devices is presented. A quadrature CMOS voltage-controlled oscillator and a 2.4 GHz direct-conversion transmitter with a power amplifier and upconversion mixer are also developed to transmit the ECG signal through wireless communication. In the receiver, a 2.4 GHz fully integrated CMOS RF front end with a low-noise amplifier, differential power splitter, and quadrature mixer based on current-reused folded architecture is proposed. The circuits have been implemented to meet the specifications of the IEEE 802.15.4 2.4 GHz standard. The low-power ICs of the wireless ECG acquisition systems have been fabricated using a 0.18 μm Taiwan Semiconductor Manufacturing Company (TSMC) CMOS standard process. The measured results on the human body reveal that ECG signals can be acquired effectively by the proposed low-power analog front-end ICs.

  15. System for unconstrained ECG measurement on a toilet seat using capacitive coupled electrodes : the efficacy and practicality.

    PubMed

    Baek, Hyun Jae; Kim, Jung Soo; Kim, Ko Keun; Park, Kwang Suk

    2008-01-01

    Home healthcare is a common matter of concern to modern people. For the successful home healthcare, unconstrained bio-signal monitoring is important. Previously, unconstrained lavatory typed ECG measurement system was developed. It is enough to measure subject's ECG signal non-intrusively, but not practical because of moist environment of toilet. In this study, capacitive coupled electrode was employed for overcome above disadvantages. ECG was obtained by capacitive coupled electrode and compared with ECGs obtained from conventional Ag/AgCl electrode. Possible motion artifacts were investigated. Experimental results showed that toilet based capacitive coupled ECG signal was measured successfully.

  16. Detection of Cardiac Abnormalities from Multilead ECG using Multiscale Phase Alternation Features.

    PubMed

    Tripathy, R K; Dandapat, S

    2016-06-01

    The cardiac activities such as the depolarization and the relaxation of atria and ventricles are observed in electrocardiogram (ECG). The changes in the morphological features of ECG are the symptoms of particular heart pathology. It is a cumbersome task for medical experts to visually identify any subtle changes in the morphological features during 24 hours of ECG recording. Therefore, the automated analysis of ECG signal is a need for accurate detection of cardiac abnormalities. In this paper, a novel method for automated detection of cardiac abnormalities from multilead ECG is proposed. The method uses multiscale phase alternation (PA) features of multilead ECG and two classifiers, k-nearest neighbor (KNN) and fuzzy KNN for classification of bundle branch block (BBB), myocardial infarction (MI), heart muscle defect (HMD) and healthy control (HC). The dual tree complex wavelet transform (DTCWT) is used to decompose the ECG signal of each lead into complex wavelet coefficients at different scales. The phase of the complex wavelet coefficients is computed and the PA values at each wavelet scale are used as features for detection and classification of cardiac abnormalities. A publicly available multilead ECG database (PTB database) is used for testing of the proposed method. The experimental results show that, the proposed multiscale PA features and the fuzzy KNN classifier have better performance for detection of cardiac abnormalities with sensitivity values of 78.12 %, 80.90 % and 94.31 % for BBB, HMD and MI classes. The sensitivity value of proposed method for MI class is compared with the state-of-art techniques from multilead ECG.

  17. Association between obesity and ECG variables in children and adolescents: A cross-sectional study

    PubMed Central

    SUN, GUO-ZHE; LI, YANG; ZHOU, XING-HU; GUO, XIAO-FAN; ZHANG, XIN-GANG; ZHENG, LI-QIANG; LI, YUAN; JIAO, YUN-DI; SUN, YING-XIAN

    2013-01-01

    Obesity exhibits a wide variety of electrocardiogram (ECG) abnormalities in adults, which often lead to cardiovascular events. However, there is currently no evidence of an association between obesity and ECG variables in children and adolescents. The present study aimed to explore the associations between obesity and ECG intervals and axes in children and adolescents. A cross-sectional observational study of 5,556 students aged 5–18 years was performed. Anthropometric data, blood pressure and standard 12-lead ECGs were collected for each participant. ECG variables were measured manually based on the temporal alignment of simultaneous 12 leads using a CV200 ECG Work Station. Overweight and obese groups demonstrated significantly longer PR intervals, wider QRS durations and leftward shifts of frontal P-wave, QRS and T-wave axes, while the obese group also demonstrated significantly higher heart rates, compared with normal weight groups within normotensive or hypertensive subjects (P<0.05). Abdominal obesity was also associated with longer PR intervals, wider QRS duration and a leftward shift of frontal ECG axes compared with normal waist circumference (WC) within normotensive or hypertensive subjects (P<0.05). Gender was a possible factor affecting the ECG variables. Furthermore, the ECG variables, including PR interval, QRS duration and frontal P-wave, QRS and T-wave axes, were significantly linearly correlated with body mass index, WC and waist-to-height ratio adjusted for age, gender, ethnicity and blood pressure. However, there was no significant association between obesity and the corrected QT interval (P>0.05). The results of the current study indicate that in children and adolescents, general and abdominal obesity is associated with longer PR intervals, wider QRS duration and a leftward shift of frontal P-wave, QRS and T-wave axes, independent of age, gender, ethnicity and blood pressure. PMID:24255675

  18. Diagnostic quality of time-averaged ECG-gated CT data

    NASA Astrophysics Data System (ADS)

    Klein, Almar; Oostveen, Luuk J.; Greuter, Marcel J. W.; Hoogeveen, Yvonne; Schultze Kool, Leo J.; Slump, Cornelis H.; Renema, W. Klaas Jan

    2009-02-01

    Purpose: ECG-gated CTA allows visualization of the aneurysm and stentgraft during the different phases of the cardiac cycle, although with a lower SNR per cardiac phase than without ECG gating using the same dose. In our institution, abdominal aortic aneurysm (AAA) is evaluated using non-ECG-gated CTA. Some common CT scanners cannot reconstruct a non-gated volume from ECG-gated acquired data. In order to obtain the same diagnostic image quality, we propose offline temporal averaging of the ECG-gated data. This process, though straightforward, is fundamentally different from taking a non-gated scan, and its result will certainly differ as well. The purpose of this study is to quantitatively investigate how good off-line averaging approximates a non-gated scan. Method: Non-gated and ECG-gated CT scans have been performed on a phantom (Catphan 500). Afterwards the phases of the ECG-gated CTA data were averaged to create a third dataset. The three sets are compared with respect to noise properties (NPS) and frequency response (MTF). To study motion artifacts identical scans were acquired on a programmable dynamic phantom. Results and Conclusions: The experiments show that the spatial frequency content is not affected by the averaging process. The minor differences observed for the noise properties and motion artifacts are in favor of the averaged data. Therefore the averaged ECG-gated phases can be used for diagnosis. This enables the use of ECG-gating for research on stentgrafts in AAA, without impairing clinical patient care.

  19. Remote sensing of cirrus cloud parameters using advanced very-high-resolution radiometer 3.7- and 1 O.9-microm channels.

    PubMed

    Ou, S C; Liou, K N; Gooch, W M; Takano, Y

    1993-04-20

    We develop a retrieval scheme by using advanced very-high-resolution radiometer (AVHRR) 3.7- and 10.9-microm data to compute simultaneously the temperature, optical depth, and mean effective ice-crystal size for cirrus clouds. The methodology involves the numerical solution of a set of nonlinear algebraic equations derived from the theory of radiative transfer. The solution requires the correlation of emissivities of two channels in terms of the effective extinction ratio. The dependence of this ratio on ice-crystal size distribution is examined by using an adding-doubling radiative transfer program. Investigation of the effects of cirrus parameters on upwelling radiances reveals that the brightnesstemperature difference between the two channels becomes larger for colder cirrus and smaller ice-crystal sizes. We apply the current retrieval scheme to satellite data collected at 0930 UTC, 28 October 1986, over the region of the First International Satellite Cloud Climatology Project Regional Experiment CirrusIntesive Field Observation. We select the data over an area (~ 44 degrees N, 92 degrees W) near Fort McCoy, Wisconsin, for analysis. The retrieved cirrus heights compare reasonably well with lidar measurements taken at Fort McCoy 2 h after a satellite overpass at the target region. The retrieved mean effective crystal size is close to that derived from in situ aircraft measurements over Madison, Wisconsin, six hours after a satellite overpass.

  20. A scoring system basing pathological parameters to predict regional lymph node metastasis after preoperative chemoradiotherapy for locally advanced rectal cancer: implication for local excision

    PubMed Central

    Wang, Xiao-Jie; Chi, Pan; Lin, Hui-Ming; Lu, Xing-Rong; Huang, Ying; Xu, Zong-Bin; Huang, Sheng-Hui; Sun, Yan-Wu; Ye, Dao-Xiong; Yu, Qian

    2016-01-01

    Local excision is an alternative to radical surgery that is indicated in patients with locally advanced rectal cancer (LARC) who have a good response to chemoradiotherapy (CRT). Regional lymph node status is a major uncertainty during local excision of LARC following CRT. We retrospectively reviewed clinicopathologic variables for 244 patients with LARC who were treated at our institute between December 2000 and December 2013 in order to identify independent predictors of regional lymph node metastasis. Multivariate analysis of the training sample demonstrated that histopathologic type, tumor size, and the presence of lymphovascular invasion were significant predictors of regional nodal metastasis. These variables were then incorporated into a scoring system in which the total scores were calculated based on the points assigned for each parameter. The area under the curve in the receiver operating characteristic analysis was 0.750, and the cutoff value for the total score to predict regional nodal metastasis was 7.5. The sensitivity of our system was 73.2% and the specificity was 69.4%. The sensitivity was 77.8% and the specificity was 51.2% when the scoring system was applied to the testing sample. Using this system, we could accurately predict regional nodal metastases in LARC patients following CRT, which may be useful for stratifying patients in clinical trials and selecting potential candidates for organ-sparing surgery following CRT for LARC PMID:27489356

  1. Analysis of Dosimetric Parameters Associated With Acute Gastrointestinal Toxicity and Upper Gastrointestinal Bleeding in Locally Advanced Pancreatic Cancer Patients Treated With Gemcitabine-Based Concurrent Chemoradiotherapy

    SciTech Connect

    Nakamura, Akira; Shibuya, Keiko; Matsuo, Yukinori; Nakamura, Mitsuhiro; Shiinoki, Takehiro; Mizowaki, Takashi; Hiraoka, Masahiro

    2012-10-01

    Purpose: To identify the dosimetric parameters associated with gastrointestinal (GI) toxicity in patients with locally advanced pancreatic cancer (LAPC) treated with gemcitabine-based chemoradiotherapy. Methods and Materials: The data from 40 patients were analyzed retrospectively. Chemoradiotherapy consisted of conventional fractionated three-dimensional radiotherapy and weekly gemcitabine. Treatment-related acute GI toxicity and upper GI bleeding (UGB) were graded according to the Common Toxicity Criteria Adverse Events, version 4.0. The dosimetric parameters (mean dose, maximal absolute dose which covers 2 cm{sup 3} of the organ, and absolute volume receiving 10-50 Gy [V{sub 10-50}]) of the stomach, duodenum, small intestine, and a composite structure of the stomach and duodenum (StoDuo) were obtained. The planning target volume was also obtained. Univariate analyses were performed to identify the predictive factors for the risk of grade 2 or greater acute GI toxicity and grade 3 or greater UGB, respectively. Results: The median follow-up period was 15.7 months (range, 4-37). The actual incidence of acute GI toxicity was 33%. The estimated incidence of UGB at 1 year was 20%. Regarding acute GI toxicity, a V{sub 50} of {>=}16 cm{sup 3} of the stomach was the best predictor, and the actual incidence in patients with V{sub 50} <16 cm{sup 3} of the stomach vs. those with V{sub 50} of {>=}16 cm{sup 3} was 9% vs. 61%, respectively (p = 0.001). Regarding UGB, V{sub 50} of {>=}33 cm{sup 3} of the StoDuo was the best predictor, and the estimated incidence at 1 year in patients with V{sub 50} <33 cm{sup 3} of the StoDuo vs. those with V{sub 50} {>=}33 cm{sup 3} was 0% vs. 44%, respectively (p = 0.002). The dosimetric parameters correlated highly with one another. Conclusion: The irradiated absolute volume of the stomach and duodenum are important for the risk of acute GI toxicity and UGB. These results could be helpful in escalating the radiation doses using novel

  2. TU-C-12A-09: Modeling Pathologic Response of Locally Advanced Esophageal Cancer to Chemo-Radiotherapy Using Quantitative PET/CT Features, Clinical Parameters and Demographics

    SciTech Connect

    Zhang, H; Chen, W; Kligerman, S; D’Souza, W; Suntharalingam, M; Lu, W; Tan, S; Kim, G

    2014-06-15

    Purpose: To develop predictive models using quantitative PET/CT features for the evaluation of tumor response to neoadjuvant chemo-radiotherapy (CRT) in patients with locally advanced esophageal cancer. Methods: This study included 20 patients who underwent tri-modality therapy (CRT + surgery) and had {sup 18}F-FDG PET/CT scans before initiation of CRT and 4-6 weeks after completion of CRT but prior to surgery. Four groups of tumor features were examined: (1) conventional PET/CT response measures (SUVmax, tumor diameter, etc.); (2) clinical parameters (TNM stage, histology, etc.) and demographics; (3) spatial-temporal PET features, which characterize tumor SUV intensity distribution, spatial patterns, geometry, and associated changes resulting from CRT; and (4) all features combined. An optimal feature set was identified with recursive feature selection and cross-validations. Support vector machine (SVM) and logistic regression (LR) models were constructed for prediction of pathologic tumor response to CRT, using cross-validations to avoid model over-fitting. Prediction accuracy was assessed via area under the receiver operating characteristic curve (AUC), and precision was evaluated via confidence intervals (CIs) of AUC. Results: When applied to the 4 groups of tumor features, the LR model achieved AUCs (95% CI) of 0.57 (0.10), 0.73 (0.07), 0.90 (0.06), and 0.90 (0.06). The SVM model achieved AUCs (95% CI) of 0.56 (0.07), 0.60 (0.06), 0.94 (0.02), and 1.00 (no misclassifications). Using spatial-temporal PET features combined with conventional PET/CT measures and clinical parameters, the SVM model achieved very high accuracy (AUC 1.00) and precision (no misclassifications), significantly better than using conventional PET/CT measures or clinical parameters and demographics alone. For groups with a large number of tumor features (groups 3 and 4), the SVM model achieved significantly higher accuracy than the LR model. Conclusion: The SVM model using all features

  3. Evaluation of novel ECG signal processing on quantification of transient ischemia and baseline wander suppression.

    PubMed

    Kostic, Marko N; Fakhar, Sina; Foxall, Tom; Drakulic, Budimir S; Krucoff, Mitchell W

    2007-01-01

    The performance assessment of a novel ECG signal processing technology in Fidelity 100 (test) and four modern ECG systems (controls) was conducted. A quantitative evaluation for one control and a test system was done by simultaneous recordings on 54 patients undergoing percutaneous coronary intervention (PCI) and on a biological reference signal from an ECG simulator. A qualitative performance of baseline wander suppression was done on all five systems. The results showed that the Fidelity 100 system provided excellent detection and quantification of transient ischemia and baseline wander suppression.

  4. Principal component analysis of atrial fibrillation: Inclusion of posterior ECG leads does not improve correlation with left atrial activity

    PubMed Central

    Raine, Daniel; Langley, Philip; Shepherd, Ewen; Lord, Stephen; Murray, Stephen; Murray, Alan; Bourke, John P.

    2015-01-01

    Background Lead V1 is routinely analysed due to its large amplitude AF waveform. V1 correlates strongly with right atrial activity but only moderately with left atrial activity. Posterior lead V9 correlates strongest with left atrial activity. Aims (1) To establish whether surface dominant AF frequency (DAF) calculated using principal component analysis (PCA) of a modified 12-lead ECG (including posterior leads) has a stronger correlation with left atrial activity compared to the standard ECG. (2) To assess the contribution of individual ECG leads to the AF principal component in both ECG configurations. Methods Patients were assigned to modified or standard ECG groups. In the modified ECG, posterior leads V8 and V9 replaced V4 and V6. AF waveform was extracted from one-minute surface ECG recordings using PCA. Surface DAF was correlated with intracardiac DAF from the high right atrium (HRA), coronary sinus (CS) and pulmonary veins (PVs). Results 96 patients were studied. Surface DAF from the modified ECG did not have a stronger correlation with left atrial activity compared to the standard ECG. Both ECG configurations correlated strongly with HRA, CS and right PVs but only moderately with left PVs. V1 contributed most to the AF principal component in both ECG configurations. PMID:25619612

  5. R-Peak Detection using Daubechies Wavelet and ECG Signal Classification using Radial Basis Function Neural Network

    NASA Astrophysics Data System (ADS)

    Rai, H. M.; Trivedi, A.; Chatterjee, K.; Shukla, S.

    2014-01-01

    This paper employed the Daubechies wavelet transform (WT) for R-peak detection and radial basis function neural network (RBFNN) to classify the electrocardiogram (ECG) signals. Five types of ECG beats: normal beat, paced beat, left bundle branch block (LBBB) beat, right bundle branch block (RBBB) beat and premature ventricular contraction (PVC) were classified. 500 QRS complexes were arbitrarily extracted from 26 records in Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) arrhythmia database, which are available on Physionet website. Each and every QRS complex was represented by 21 points from p1 to p21 and these QRS complexes of each record were categorized according to types of beats. The system performance was computed using four types of parameter evaluation metrics: sensitivity, positive predictivity, specificity and classification error rate. The experimental result shows that the average values of sensitivity, positive predictivity, specificity and classification error rate are 99.8%, 99.60%, 99.90% and 0.12%, respectively with RBFNN classifier. The overall accuracy achieved for back propagation neural network (BPNN), multilayered perceptron (MLP), support vector machine (SVM) and RBFNN classifiers are 97.2%, 98.8%, 99% and 99.6%, respectively. The accuracy levels and processing time of RBFNN is higher than or comparable with BPNN, MLP and SVM classifiers.

  6. Assessment of chaotic parameters in nonstationary electrocardiograms by use of empirical mode decomposition.

    PubMed

    Salisbury, John I; Sun, Ying

    2004-10-01

    This study addressed the issue of assessing chaotic parameters from nonstationary electrocardiogram (ECG) signals. The empirical mode decomposition (EMD) was proposed as a method to extract intrinsic mode functions (IMFs) from ECG signals. Chaos analysis methods were then applied to the stationary IMFs without violating the underlying assumption of stationarity. Eight ECG data sets representing normal and various abnormal rhythms were obtained from the American Heart Associate Ventricular Arrhythmia database. The chaotic parameters including Lyapunov exponent, entropy, and correlation dimension were computed. The results consistently showed that the 10th IMF (IMF-10) was stationary and preserved sufficient nonlinearity of the ECG signals. Each IMF-10 from the data sets (n = 8) gave a positive dominate Lyapunov exponent (0.29-0.64, p < 0.0001), a positive entropy (0.039-0.061, p < 0.0001), and a noninteger correlation dimension (1.1-1.9). These were evidences of a chaotic dynamic system. We therefore concluded that the original ECG signals must also have chaotic properties. The chaotic parameters did not show significant differences among the eight data sets representing normal sinus rhythm and various abnormalities. This study has demonstrated an effective way to characterize nonlinearities in nonstationary ECG signals by combining the empirical mode decomposition and the chaos analysis methods.

  7. CinC Challenge 2013: comparing three algorithms to extract fetal ECG

    NASA Astrophysics Data System (ADS)

    Loja, Juan; Velecela, Esteban; Palacio-Baus, Kenneth; Astudillo, Darwin; Medina, Rubén.; Wong, Sara

    2015-12-01

    This paper reports a comparison between three fetal ECG (fECG) detectors developed during the CinC 2013 challenge for fECG detection. Algorithm A1 is based on Independent Component Analysis, A2 is based on fECG detection of RS Slope and A3 is based on Expectation-Weighted Estimation of Fiducial Points. The proposed methodology was validated using the annotated database available for the challenge. Each detector was characterized in terms of its performance by using measures of sensitivity, (Se), positive predictive value (P+) and delay time (td). Additionally, the database was contaminated with white noise for two SNR conditions. Decision fusion was tested considering the most common types of combination of detectors. Results show that the decision fusion of A1 and A2 improves fQRS detection, maintaining high Se and P+ even under low SNR conditions without a significant td increase.

  8. Design and implementation of a 3-lead ECG wireless remote monitoring system

    NASA Astrophysics Data System (ADS)

    Zhang, Shi; Jia, Xiaonan; Shang, Shuai

    2006-11-01

    Cardiovascular disease is one of the main diseases that menaces human health. It is necessary to monitor the patient's real-time electrocardiograph (ECG) for a long time to realize diagnosis and salvage. Remote ECG monitoring system is the solution. This paper introduces the design and implement of a 3-lead ECG wireless remote monitoring system. It collects, stores and transmits user's ECG which can be received by hospital and diagnosed by doctors. The development of the whole system contains three parts, the hardware and embedded software implementation of MONITOR, software of the MONITORING CENTER, and the routing software of NETWORK CENTER. According to the clinic experimentation, this system has high reliability and utility. There will be great social and economic benefit if this system is put into use.

  9. Segmentation of ECG from Surface EMG Using DWT and EMD: A Comparison Study

    NASA Astrophysics Data System (ADS)

    Shahbakhti, Mohammad; Heydari, Elnaz; Luu, Gia Thien

    2014-10-01

    The electrocardiographic (ECG) signal is a major artifact during recording the surface electromyography (SEMG). Removal of this artifact is one of the important tasks before SEMG analysis for biomedical goals. In this paper, the application of discrete wavelet transform (DWT) and empirical mode decomposition (EMD) for elimination of ECG artifact from SEMG is investigated. The focus of this research is to reach the optimized number of decomposed levels using mean power frequency (MPF) by both techniques. In order to implement the proposed methods, ten simulated and three real ECG contaminated SEMG signals have been tested. Signal-to-noise ratio (SNR) and mean square error (MSE) between the filtered and the pure signals are applied as the performance indexes of this research. The obtained results suggest both techniques could remove ECG artifact from SEMG signals fair enough, however, DWT performs much better and faster in real data.

  10. An ECG ambulatory system with mobile embedded architecture for ST-segment analysis.

    PubMed

    Miranda-Cid, Alejandro; Alvarado-Serrano, Carlos

    2010-01-01

    A prototype of a ECG ambulatory system for long term monitoring of ST segment of 3 leads, low power, portability and data storage in solid state memory cards has been developed. The solution presented is based in a mobile embedded architecture of a portable entertainment device used as a tool for storage and processing of bioelectric signals, and a mid-range RISC microcontroller, PIC 16F877, which performs the digitalization and transmission of ECG. The ECG amplifier stage is a low power, unipolar voltage and presents minimal distortion of the phase response of high pass filter in the ST segment. We developed an algorithm that manages access to files through an implementation for FAT32, and the ECG display on the device screen. The records are stored in TXT format for further processing. After the acquisition, the system implemented works as a standard USB mass storage device.

  11. A PD control-based QRS detection algorithm for wearable ECG applications.

    PubMed

    Choi, Changmok; Kim, Younho; Shin, Kunsoo

    2012-01-01

    We present a QRS detection algorithm for wearable ECG applications using a proportional-derivative (PD) control. ECG data of arrhythmia have irregular intervals and magnitudes of QRS waves that impede correct QRS detection. To resolve the problem, PD control is applied to avoid missing a small QRS wave followed from a large QRS wave and to avoid falsely detecting noise as QRS waves when an interval between two adjacent QRS waves is large (e.g. bradycardia, pause, and arioventricular block). ECG data was obtained from 78 patients with various cardiovascular diseases and tested for the performance evaluation of the proposed algorithm. The overall sensitivity and positive predictive value were 99.28% and 99.26%, respectively. The proposed algorithm has low computational complexity, so that it can be suitable to apply mobile ECG monitoring system in real time.

  12. Check your biosignals here: a new dataset for off-the-person ECG biometrics.

    PubMed

    da Silva, Hugo Plácido; Lourenço, André; Fred, Ana; Raposo, Nuno; Aires-de-Sousa, Marta

    2014-02-01

    The Check Your Biosignals Here initiative (CYBHi) was developed as a way of creating a dataset and consistently repeatable acquisition framework, to further extend research in electrocardiographic (ECG) biometrics. In particular, our work targets the novel trend towards off-the-person data acquisition, which opens a broad new set of challenges and opportunities both for research and industry. While datasets with ECG signals collected using medical grade equipment at the chest can be easily found, for off-the-person ECG data the solution is generally for each team to collect their own corpus at considerable expense of resources. In this paper we describe the context, experimental considerations, methods, and preliminary findings of two public datasets created by our team, one for short-term and another for long-term assessment, with ECG data collected at the hand palms and fingers.

  13. Misinterpretation of the mouse ECG: ‘musing the waves of Mus musculus’

    PubMed Central

    Boukens, Bastiaan J; Rivaud, Mathilde R; Rentschler, Stacey; Coronel, Ruben

    2014-01-01

    The ECG is a primary diagnostic tool in patients suffering from heart disease, underscoring the importance of understanding factors contributing to normal and abnormal electrical patterns. Over the past few decades, transgenic mouse models have been increasingly used to study pathophysiological mechanisms of human heart diseases. In order to allow extrapolation of insights gained from murine models to the human condition, knowledge of the similarities and differences between the mouse and human ECG is of crucial importance. In this review, we briefly discuss the physiological mechanisms underlying differences between the baseline ECG of humans and mice, and provide a framework for understanding how these inherent differences are relevant to the interpretation of the mouse ECG during pathology and to the translation of the results from the mouse to man. PMID:25260630

  14. An innovative non-contact ECG sensor for monitoring heart disease

    NASA Astrophysics Data System (ADS)

    Sun, Ye; Yu, Xiong (Bill); Berilla, Jim

    2011-06-01

    This paper describes the development of a non-contact sensing platform to monitor the ECG signals. The non-contact sensing will be based on capacitive coupling the bioelectricity produced by cardiovascular activities around the heart. High sensitivity sensor and electronics are designed to amplify the signals. Our preliminary study has pointed to the promise of this sensing concept. A sensor prototype was able to clearly detect the ECG signals from 10 cm away from the body. Research tasks continue improving the sensor design to detect the polarization in the ECG signals. The final goal is a non-contact sensing platform for ECG signals and for real time diagnostics of the mental distress and cardiovascular diseases.

  15. Adaptive sensing of ECG signals using R-R interval prediction.

    PubMed

    Nakaya, Shogo; Nakamura, Yuichi

    2013-01-01

    There is growing demand for systems consisting of tiny sensor nodes powered with small batteries that acquire electrocardiogram (ECG) data and wirelessly transmit the data to remote base stations or mobile phones continuously over a long period. Conserving electric power in the wireless sensor nodes (WSNs) is essential in such systems. Adaptive sensing is promising for this purpose since it can reduce the energy consumed not only for data transmission but also for sensing. However, the basic method of adaptive sensing, referred to here as "plain adaptive sensing," is not suitable for ECG signals because it sometimes capture the R waves defectively. We introduce an improved adaptive sensing method for ECG signals by incorporating R-R interval prediction. Our method improves the characteristics of ECG compression and drastically reduces the total energy consumption of the WSNs.

  16. A Human ECG Identification System Based on Ensemble Empirical Mode Decomposition

    PubMed Central

    Zhao, Zhidong; Yang, Lei; Chen, Diandian; Luo, Yi

    2013-01-01

    In this paper, a human electrocardiogram (ECG) identification system based on ensemble empirical mode decomposition (EEMD) is designed. A robust preprocessing method comprising noise elimination, heartbeat normalization and quality measurement is proposed to eliminate the effects of noise and heart rate variability. The system is independent of the heart rate. The ECG signal is decomposed into a number of intrinsic mode functions (IMFs) and Welch spectral analysis is used to extract the significant heartbeat signal features. Principal component analysis is used reduce the dimensionality of the feature space, and the K-nearest neighbors (K-NN) method is applied as the classifier tool. The proposed human ECG identification system was tested on standard MIT-BIH ECG databases: the ST change database, the long-term ST database, and the PTB database. The system achieved an identification accuracy of 95% for 90 subjects, demonstrating the effectiveness of the proposed method in terms of accuracy and robustness. PMID:23698274

  17. A Primary Study of Indirect ECG Monitor Embedded in a Bed for Home Health Care

    NASA Astrophysics Data System (ADS)

    Ueno, Akinori; Shiogai, Yuuki; Ishiyama, Yoji

    A system for monitoring electrocardiogram (ECG) through clothes inserted between the measuring electrodes and the body surface of a subject when lying on a mattress has been proposed. The principle of the system is based on capacitive coupling involving the electrode, the clothes, and the skin. Validation of the system revealed the following: (1) In spite of the gain attenuation in the pass band of the system, distortion of the detected signal was subtle even when clothes thicker than 1mm were inserted, (2) The system was able to yield a stable ECG from a subject particularly during sound sleep, (3) The system succeeded in detecting ECG after changing the posture into any of supine, right lateral, or left lateral positions by adopting a newly devised electrode configuration. Therefore, the proposed system appears promising for application to bedding as a non-invasive and awareness-free system for ECG monitoring during sleep.

  18. [Study on mobile phone based wireless ECG monitoring technology system typical demonstration applications].

    PubMed

    Yu, Yang; Liu, Jing

    2011-01-01

    Based on the mobile phone platform with wireless real-time ECG monitoring system developed in our lab, this article is dedicated to evaluate its practical value in people test. A series of new conceptual experiments were designed and performed. Particularly, ECG characteristics under different age, gender, health and motion conditions are evaluated. Effects of living habits such as drinking wine, coffee including various psychological conditions such as excitation, anxiety etc. to the ECG response are investigated. The human ECG under different time in a day such as morning, afternoon and late-night was evaluated. These conceptual experiments, which are hard to conduct otherwise using conventional devices, demonstrate the pervasive merits of the new system for fundamental study of heart disease as well as daily healthcare.

  19. Treatment of Locally Advanced Vaginal Cancer With Radiochemotherapy and Magnetic Resonance Image-Guided Adaptive Brachytherapy: Dose-Volume Parameters and First Clinical Results

    SciTech Connect

    Dimopoulos, Johannes C.A.; Schmid, Maximilian P.; Fidarova, Elena; Berger, Daniel; Kirisits, Christian; Poetter, Richard

    2012-04-01

    Purpose: To investigate the clinical feasibility of magnetic resonance image-guided adaptive brachytherapy (IGABT) for patients with locally advanced vaginal cancer and to report treatment outcomes. Methods and Materials: Thirteen patients with vaginal cancer were treated with external beam radiotherapy (45-50.4 Gy) plus IGABT with or without chemotherapy. Distribution of International Federation of Gynecology and Obstetrics stages among patients were as follows: 4 patients had Stage II cancer, 5 patients had Stage III cancer, and 4 patients had Stage IV cancer. The concept of IGABT as developed for cervix cancer was transferred and adapted for vaginal cancer, with corresponding treatment planning and reporting. Doses were converted to the equivalent dose in 2 Gy, applying the linear quadratic model ({alpha}/{beta} = 10 Gy for tumor; {alpha}/{beta} = 3 for organs at risk). Endpoints studied were gross tumor volume (GTV), dose-volume parameters for high-risk clinical target volume (HRCTV), and organs at risk, local control (LC), adverse side effects, and survival. Results: The mean GTV ({+-} 1 standard deviation) at diagnosis was 45.3 ({+-}30) cm{sup 3}, and the mean GTV at brachytherapy was 10 ({+-}14) cm{sup 3}. The mean D90 for the HRCTV was 86 ({+-}13) Gy. The mean D2cc for bladder, urethra, rectum, and sigmoid colon were 80 ({+-}20) Gy, 76 ({+-}16) Gy, 70 ({+-}9) Gy, and 60 ({+-}9) Gy, respectively. After a median follow-up of 43 months (range, 19-87 months), one local recurrence and two distant metastases cases were observed. Actuarial LC and overall survival rates at 3 years were 92% and 85%. One patient with Stage IVA and 1 patient with Stage III disease experienced fistulas (one vesicovaginal, one rectovaginal), and 1 patient developed periurethral necrosis. Conclusions: The concept of IGABT, originally developed for treating cervix cancer, appears to be applicable to vaginal cancer treatment with only minor adaptations. Dose-volume parameters for HRCTV and

  20. MRI-Guided 3D Optimization Significantly Improves DVH Parameters of Pulsed-Dose-Rate Brachytherapy in Locally Advanced Cervical Cancer

    SciTech Connect

    Lindegaard, Jacob C. Tanderup, Kari; Nielsen, Soren Kynde; Haack, Soren; Gelineck, John

    2008-07-01

    Purpose: To compare dose-volume histogram parameters of standard Point A and magnetic resonance imaging-based three-dimensional optimized dose plans in 21 consecutive patients who underwent pulsed-dose-rate brachytherapy (PDR-BT) for locally advanced cervical cancer. Methods and Materials: All patients received external beam radiotherapy (elective target dose, 45 Gy in 25-30 fractions; tumor target dose, 50-60 Gy in 25-30 fractions). PDR-BT was applied with a tandem-ring applicator. Additional ring-guided titanium needles were used in 4 patients and a multichannel vaginal cylinder in 2 patients. Dose planning was done using 1.5 Tesla T{sub 1}-weighted and T{sub 2}-weighted paratransversal magnetic resonance imaging scans. T{sub 1}-weighted visible oil-containing tubes were used for applicator reconstruction. The prescribed standard dose for PDR-BT was 10 Gy (1 Gy/pulse, 1 pulse/h) for two to three fractions to reach a physical dose of 80 Gy to Point A. The total dose (external beam radiotherapy plus brachytherapy) was normalized to an equivalent dose in 2-Gy fractions using {alpha}/{beta} = 10 Gy for tumor, {alpha}/{beta} = 3 Gy for normal tissue, and a repair half-time of 1.5 h. The goal of optimization was dose received by 90% of the target volume (D{sub 90}) of {>=}85 Gy{sub {alpha}}{sub /{beta}}{sub 10} in the high-risk clinical target volume (cervix and remaining tumor at brachytherapy), but keeping the minimal dose to 2 cm{sup 3} of the bladder and rectum/sigmoid at <90 and <75 Gy{sub {alpha}}{sub /{beta}}{sub 3}, respectively. Results: Using three-dimensional optimization, all dose-volume histogram constraints were met in 16 of 21 patients compared with 3 of 21 patients with two-dimensional library plans (p < 0.001). Optimization increased the minimal target dose (D{sub 100}) of the high-risk clinical target volume (p < 0.007) and decreased the minimal dose to 2 cm{sup 3} for the sigmoid significantly (p = 0.03). For the high-risk clinical target volume, D

  1. Use of ECG and Other Simple Non-Invasive Tools to Assess Pulmonary Hypertension

    PubMed Central

    Kovacs, Gabor; Avian, Alexander; Foris, Vasile; Tscherner, Maria; Kqiku, Xhylsime; Douschan, Philipp; Bachmaier, Gerhard; Olschewski, Andrea; Matucci-Cerinic, Marco; Olschewski, Horst

    2016-01-01

    Background There is a broad consensus that pulmonary hypertension (PH) is to be diagnosed by right heart catheterization (RHC) and that the most important non-invasive tool is echocardiography. However, the role of simple non-invasive tools in the work-up of PH is not clearly defined. We hypothesized that the use of simple non-invasive techniques may help to guide important decisions in the diagnostics of pulmonary hypertension. Objectives We aimed to develop an algorithm with the use of simple, non-invasive tools in order to identify patients with very high or very low likelihood of PH. Methods We retrospectively analyzed all consecutive patients undergoing RHC between 2005 and 2010 in our center and performed logistic regression of simple non-invasive parameters regarding detection and exclusion of PH and derived a two-step algorithm. In a prospective study we evaluated this algorithm between 2011 and 2013. Results The retrospective cohort consisted of n = 394 patients of which 49% presented with PH. Right axis deviation in the ECG was present in 90/394 patients and had a positive predictive value (PPV) of 93% for PH. The combination of non-right axis deviation, N-terminal pro brain natriuretic peptide (NT-proBNP)<333pg/ml, arterial oxygen saturation (SO2)≥95.5% and WHO functional class I-II was present in 69/394 patients and excluded PH with a negative predictive value (NPV) of 96%. The prospective study confirmed these results in a cohort of n = 168 patients (PPV:92%, NPV:97%). Taken together, simple non-invasive tools allowed a prediction regarding the presence or absence of PH in 42% of patients with suspected PH. Conclusion ECG, NT-proBNP, SO2 and WHO functional class may predict the presence or absence of PH in almost half of the patients with suspected PH, suggesting an important role for these variables in the work-up of patients at risk for PH. Clinical Trial Registration NCT01607502 PMID:28030578

  2. Multifractal properties of ECG patterns of patients suffering from congestive heart failure

    NASA Astrophysics Data System (ADS)

    Dutta, Srimonti

    2010-12-01

    The multifractal properties of two-channel ECG patterns of patients suffering from severe congestive heart failure (New York Heart Association (NYHA) classes III-IV) are studied and are compared with those for normal healthy people using the multifractal detrended fluctuation analysis methodology. Ivanov et al (1999 Nature 399 461) have studied the multifractality of human heart rate dynamics using the wavelet transformation modulus maxima (WTMM) methodology. But it has been observed by several scientists that multifractal detrended fluctuation analysis (MFDFA) works better than the WTMM method in the detection of monofractal and multifractal characteristics of the data. Galaska et al (2008 Ann. Noninvasive Electrocardiol. 13 155) have observed that MFDFA is more sensitive compared to the WTMM method in the differentiation between multifractal properties of the heart rate in healthy subjects and patients with left ventricular systolic dysfunction. In the present work the variation of two parameters of the multifractal spectrum—its width W (related to the degree of multifractality) and the value of the Hölder exponent α0—for the healthy and congestive heart failure patients is studied. α0 is a measure of the degree of correlation. The degree of multifractality varies appreciably (85-90% C.L.) for the normal and the CHF sets for channel I. For channel II no significant change in the values is observed. The degree of correlation is found to be comparatively high for the normal healthy people compared to those suffering from CHF.

  3. [Development of a portable ECG monitor with diagnostic & therapeutic functions and its clinical applications].

    PubMed

    Fan, Shou-nian; Jiang, Chen-xi; Cai, Yun-chang; Liu, Jun-shi; Fan, Yuan-yuan; Liu, Zhi-qin; Zhao, Ning; Wu, Qiang

    2005-01-01

    A portable ECG monitor is introduced in the paper, which has a temporary intravenous and transesophageal fixable rate pacing function. During the PSVT attack, the tachyarrythmia can be stopped by the transesophageal cardiac pacing while the ECG signals are monitored. The instrument has some advantages such as small size, low price and good practicality. It is worth while introducing and popularizing it to all hospitals.

  4. Motion artifact removal algorithm by ICA for e-bra: a women ECG measurement system

    NASA Astrophysics Data System (ADS)

    Kwon, Hyeokjun; Oh, Sechang; Varadan, Vijay K.

    2013-04-01

    Wearable ECG(ElectroCardioGram) measurement systems have increasingly been developing for people who suffer from CVD(CardioVascular Disease) and have very active lifestyles. Especially, in the case of female CVD patients, several abnormal CVD symptoms are accompanied with CVDs. Therefore, monitoring women's ECG signal is a significant diagnostic method to prevent from sudden heart attack. The E-bra ECG measurement system from our previous work provides more convenient option for women than Holter monitor system. The e-bra system was developed with a motion artifact removal algorithm by using an adaptive filter with LMS(least mean square) and a wandering noise baseline detection algorithm. In this paper, ICA(independent component analysis) algorithms are suggested to remove motion artifact factor for the e-bra system. Firstly, the ICA algorithms are developed with two kinds of statistical theories: Kurtosis, Endropy and evaluated by performing simulations with a ECG signal created by sgolayfilt function of MATLAB, a noise signal including 0.4Hz, 1.1Hz and 1.9Hz, and a weighed vector W estimated by kurtosis or entropy. A correlation value is shown as the degree of similarity between the created ECG signal and the estimated new ECG signal. In the real time E-Bra system, two pseudo signals are extracted by multiplying with a random weighted vector W, the measured ECG signal from E-bra system, and the noise component signal by noise extraction algorithm from our previous work. The suggested ICA algorithm basing on kurtosis or entropy is used to estimate the new ECG signal Y without noise component.

  5. ECG Segmentation and P-Wave Feature Extraction: Application to Patients Prone to Atrial Fibrillation

    DTIC Science & Technology

    2007-11-02

    detection of patients prone to atrial fibrillation (AF), one of the most frequent arrhythmias. It focuses first on the segmentation of the...Keywords : atrial fibrillation , ECG segmentation, P-wave, hidden Markov model, wavelets, ECG database I. INTRODUCTION Atrial fibrillation (AF) is a very... atrial thrombosis, with the subsequent risk of a stroke. The aim of this study is to try to automatically detect patients prone to atrial fibrillation (AF

  6. Agreement between a smart-phone pulse sensor application and ECG for determining lnRMSSD.

    PubMed

    Esco, Michael R; Flatt, Andrew A; Nakamura, Fabio Y

    2016-06-27

    The purpose of this study was to determine the agreement between a smartphone pulse finger sensor (SPFS) and electrocardiography (ECG) for determining ultra-short-term heart rate variability (HRV) in three different positions. Thirty college-aged men (n = 15) and women (n = 15) volunteered to participate in this study. Sixty second heart rate measures were simultaneously taken with the SPFS and ECG in supine, seated and standing positions. lnRMSSD was calculated from the SPFS and ECG. The lnRMSSD values were 81.5 ± 11.7 via ECG and 81.6 ± 11.3 via SPFS (p = 0.63, Cohen's d = 0.01) in the supine position, 76.5 ± 8.2 via ECG and 77.5 ± 8.2 via SPFS (p = 0.007, Cohen's d = 0.11) in the seated position, and 66.5 ± 9.2 via ECG and 67.8 ± 9.1 via SPFS (p < 0.001, Cohen's d = 0.15) in the standing positions. The SPFS showed a possibly strong correlation to the ECG in all three positions (r values from 0.98 to 0.99). In addition, the limits of agreement (CE ± 1.98 SD) were -0.13 ± 2.83 for the supine values, -0.94± 3.47 for the seated values, and -1.37 ± 3.56 for the standing values. The results of the study suggest good agreement between the SPFS and ECG for measuring lnRMSSD in supine, seated, and standing positions. Though significant differences were noted between the two methods in the seated and standing positions, the effect sizes were trivial.

  7. ECG Response of Koalas to Tourists Proximity: A Preliminary Study

    PubMed Central

    Ropert-Coudert, Yan; Brooks, Lisa; Yamamoto, Maki; Kato, Akiko

    2009-01-01

    Koalas operate on a tight energy budget and, thus, may not always display behavioral avoidance reaction when placed in a stressful condition. We investigated the physiological response of captive koalas Phascolarctos cinereus in a conservation centre to the presence of tourists walking through their habitat. We compared, using animal-attached data-recorders, the electrocardiogram activity of female koalas in contact with tourists and in a human-free area. One of the koalas in the tourist zone presented elevated heart rate values and variability throughout the recording period. The remaining female in the exhibit area showed a higher field resting heart rates during the daytime than that in the isolated area. In the evening, heart rate profiles changed drastically and both the koalas in the exhibit and in the tourist-free zones displayed similar field resting heart rates, which were lower than those during the day. In parallel, the autonomic nervous systems of these two individuals evolved from sympathetic-dominant during the day to parasympathetic-dominant in the evening. Our results report ECG of free-living koalas for the first time. Although they are preliminary due to the difficulty of having sufficient samples of animals of the same sex and age, our results stress out the importance of studies investigating the physiological reaction of animals to tourists. PMID:19823679

  8. Ambulatory respiratory rate detection using ECG and a triaxial accelerometer.

    PubMed

    Chan, Alexander M; Ferdosi, Nima; Narasimhan, Ravi

    2013-01-01

    Continuous monitoring of respiratory rate in ambulatory conditions has widespread applications for screening of respiratory diseases and remote patient monitoring. Unfortunately, minimally obtrusive techniques often suffer from low accuracy. In this paper, we describe an algorithm with low computational complexity for combining multiple respiratory measurements to estimate breathing rate from an unobtrusive chest patch sensor. Respiratory rates derived from the respiratory sinus arrhythmia (RSA) and modulation of the QRS amplitude of electrocardiography (ECG) are combined with a respiratory rate derived from tri-axial accelerometer data. The three respiration rates are combined by a weighted average using weights based on quality metrics for each signal. The algorithm was evaluated on 15 elderly subjects who performed spontaneous and metronome breathing as well as a variety of activities of daily living (ADLs). When compared to a reference device, the mean absolute error was 1.02 breaths per minute (BrPM) during metronome breathing, 1.67 BrPM during spontaneous breathing, and 2.03 BrPM during ADLs.

  9. Wireless long-term ECG integrated into clothing.

    PubMed

    Despang, Hans Günter; Netz, Steffen; Heinig, Andreas; Holland, Hans Jürgen; Fischer, Wolf Joachim

    2008-12-01

    The integration of electronic devices into clothing to monitor biosignals is demonstrated with the integration of a 3-channel ECG device into a shirt. It is shown that several basic requirements concerning the electronic design must be fulfilled, exceeding the capabilities of conventional portable systems. The application of flexible connection and housing technologies is addressed in the present paper. Printed boards should be flexible enough to adapt to movements of the human body. Small size as well as water-resistant or even washable construction is required. Additional points concern replacing the disturbing loose cable connections with a more integrated solution. A long period of operation without recharging the battery, uploading the data or changing the electrodes has to be achieved. The system should feature an uninterrupted 7-day operation period known as 24/7-monitoring regime. Starting with its specification, the basic design of the prototype is presented. First investigations have shown the washability of the shirt together with the inserted electronics.

  10. Investigations of sensitivity and resolution of ECG and MCG in a realistically shaped thorax model.

    PubMed

    Mäntynen, Ville; Konttila, Teijo; Stenroos, Matti

    2014-12-07

    Solving the inverse problem of electrocardiography (ECG) and magnetocardiography (MCG) is often referred to as cardiac source imaging. Spatial properties of ECG and MCG as imaging systems are, however, not well known. In this modelling study, we investigate the sensitivity and point-spread function (PSF) of ECG, MCG, and combined ECG+MCG as a function of source position and orientation, globally around the ventricles: signal topographies are modelled using a realistically-shaped volume conductor model, and the inverse problem is solved using a distributed source model and linear source estimation with minimal use of prior information. The results show that the sensitivity depends not only on the modality but also on the location and orientation of the source and that the sensitivity distribution is clearly reflected in the PSF. MCG can better characterize tangential anterior sources (with respect to the heart surface), while ECG excels with normally-oriented and posterior sources. Compared to either modality used alone, the sensitivity of combined ECG+MCG is less dependent on source orientation per source location, leading to better source estimates. Thus, for maximal sensitivity and optimal source estimation, the electric and magnetic measurements should be combined.

  11. Real-time CHF detection from ECG signals using a novel discretization method.

    PubMed

    Orhan, Umut

    2013-10-01

    This study proposes a new method, equal frequency in amplitude and equal width in time (EFiA-EWiT) discretization, to discriminate between congestive heart failure (CHF) and normal sinus rhythm (NSR) patterns in ECG signals. The ECG unit pattern concept was introduced to represent the standard RR interval, and our method extracted certain features from the unit patterns to classify by a primitive classifier. The proposed method was tested on two classification experiments by using ECG records in Physiobank databases and the results were compared to those from several previous studies. In the first experiment, an off-line classification was performed with unit patterns selected from long ECG segments. The method was also used to detect CHF by real-time ECG waveform analysis. In addition to demonstrating the success of the proposed method, the results showed that some unit patterns in a long ECG segment from a heart patient were more suggestive of disease than the others. These results indicate that the proposed approach merits additional research.

  12. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography.

    PubMed

    Penzel, Thomas; Kantelhardt, Jan W; Bartsch, Ronny P; Riedl, Maik; Kraemer, Jan F; Wessel, Niels; Garcia, Carmen; Glos, Martin; Fietze, Ingo; Schöbel, Christoph

    2016-01-01

    The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However, their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG, and cardio-respiratory couplings in a chronological (historical) sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability (HRV) analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave).

  13. ECG Wave-Maven: a self-assessment program for students and clinicians.

    PubMed Central

    Nathanson, L. A.; Safran, C.; McClennen, S.; Goldberger, A. L.

    2001-01-01

    Proficiency in the interpretation of electrocardiograms (ECGs) is an essential skill for medical students, house officers, and attending physicians. However, resources to develop and upgrade the necessary high level of "ECG literacy" are limited. A small number of centers have attempted to address this challenge by developing "ECG of the week" internet sites. These resources are difficult to maintain and update, and many of them quickly become stagnant. We present "ECG Wave-Maven," an innovative web-based tutorial that overcomes these obstacles via a direct link to the hospital's extensive and increasing clinical ECG repository. By interfacing our educational tool to live data, we can greatly decrease the time and effort required from the time a practitioner notes an interesting case to its inclusion in the program. Users can opt to encounter the test cases sequentially or randomly, or by reviewing a list of questions or diagnoses, making this not just a quiz, but a basic educational reference. This tool may be useful in meeting the challenge of reducing serious medical errors related to ECG misinterpretation. PMID:11825236

  14. Genetic algorithm for the optimization of features and neural networks in ECG signals classification

    NASA Astrophysics Data System (ADS)

    Li, Hongqiang; Yuan, Danyang; Ma, Xiangdong; Cui, Dianyin; Cao, Lu

    2017-01-01

    Feature extraction and classification of electrocardiogram (ECG) signals are necessary for the automatic diagnosis of cardiac diseases. In this study, a novel method based on genetic algorithm-back propagation neural network (GA-BPNN) for classifying ECG signals with feature extraction using wavelet packet decomposition (WPD) is proposed. WPD combined with the statistical method is utilized to extract the effective features of ECG signals. The statistical features of the wavelet packet coefficients are calculated as the feature sets. GA is employed to decrease the dimensions of the feature sets and to optimize the weights and biases of the back propagation neural network (BPNN). Thereafter, the optimized BPNN classifier is applied to classify six types of ECG signals. In addition, an experimental platform is constructed for ECG signal acquisition to supply the ECG data for verifying the effectiveness of the proposed method. The GA-BPNN method with the MIT-BIH arrhythmia database achieved a dimension reduction of nearly 50% and produced good classification results with an accuracy of 97.78%. The experimental results based on the established acquisition platform indicated that the GA-BPNN method achieved a high classification accuracy of 99.33% and could be efficiently applied in the automatic identification of cardiac arrhythmias.

  15. Development of a portable Linux-based ECG measurement and monitoring system.

    PubMed

    Tan, Tan-Hsu; Chang, Ching-Su; Huang, Yung-Fa; Chen, Yung-Fu; Lee, Cheng

    2011-08-01

    This work presents a portable Linux-based electrocardiogram (ECG) signals measurement and monitoring system. The proposed system consists of an ECG front end and an embedded Linux platform (ELP). The ECG front end digitizes 12-lead ECG signals acquired from electrodes and then delivers them to the ELP via a universal serial bus (USB) interface for storage, signal processing, and graphic display. The proposed system can be installed anywhere (e.g., offices, homes, healthcare centers and ambulances) to allow people to self-monitor their health conditions at any time. The proposed system also enables remote diagnosis via Internet. Additionally, the system has a 7-in. interactive TFT-LCD touch screen that enables users to execute various functions, such as scaling a single-lead or multiple-lead ECG waveforms. The effectiveness of the proposed system was verified by using a commercial 12-lead ECG signal simulator and in vivo experiments. In addition to its portability, the proposed system is license-free as Linux, an open-source code, is utilized during software development. The cost-effectiveness of the system significantly enhances its practical application for personal healthcare.

  16. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography

    PubMed Central

    Penzel, Thomas; Kantelhardt, Jan W.; Bartsch, Ronny P.; Riedl, Maik; Kraemer, Jan F.; Wessel, Niels; Garcia, Carmen; Glos, Martin; Fietze, Ingo; Schöbel, Christoph

    2016-01-01

    The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However, their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG, and cardio-respiratory couplings in a chronological (historical) sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability (HRV) analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave). PMID:27826247

  17. Wavelet-Based ECG Steganography for Protecting Patient Confidential Information in Point-of-Care Systems.

    PubMed

    Ibaida, Ayman; Khalil, Ibrahim

    2013-12-01

    With the growing number of aging population and a significant portion of that suffering from cardiac diseases, it is conceivable that remote ECG patient monitoring systems are expected to be widely used as point-of-care (PoC) applications in hospitals around the world. Therefore, huge amount of ECG signal collected by body sensor networks from remote patients at homes will be transmitted along with other physiological readings such as blood pressure, temperature, glucose level, etc., and diagnosed by those remote patient monitoring systems. It is utterly important that patient confidentiality is protected while data are being transmitted over the public network as well as when they are stored in hospital servers used by remote monitoring systems. In this paper, a wavelet-based steganography technique has been introduced which combines encryption and scrambling technique to protect patient confidential data. The proposed method allows ECG signal to hide its corresponding patient confidential data and other physiological information thus guaranteeing the integration between ECG and the rest. To evaluate the effectiveness of the proposed technique on the ECG signal, two distortion measurement metrics have been used: the percentage residual difference and the wavelet weighted PRD. It is found that the proposed technique provides high-security protection for patients data with low (less than 1%) distortion and ECG data remain diagnosable after watermarking (i.e., hiding patient confidential data) and as well as after watermarks (i.e., hidden data) are removed from the watermarked data.

  18. Artificial neural network-based classification of body movements in ambulatory ECG signal.

    PubMed

    Darji, Sachin T; Kher, Rahul K

    2013-11-01

    Abstract Ambulatory ECG monitoring provides electrical activity of the heart when a person is involved in doing normal routine activities. Thus, the recorded ECG signal consists of cardiac signal along with motion artifacts introduced due to a person's body movements during routine activities. Detection of motion artifacts due to different physical activities might help in further cardiac diagnosis. Ambulatory ECG signal analysis for detection of various motion artifacts using adaptive filtering approach is addressed in this paper. We have used BIOPAC MP 36 system for acquiring ECG signal. The ECG signals of five healthy subjects (aged between 22-30 years) were recorded while the person performed various body movements like up and down movement of the left hand, up and down movement of the right hand, waist twisting movement while standing and change from sitting down on a chair to standing up movement in lead I configuration. An adaptive filter-based approach has been used to extract the motion artifact component from the ambulatory ECG signal. The features of motion artifact signal, extracted using Gabor transform, have been used to train the artificial neural network (ANN) for classifying body movements.

  19. Low-cost compact ECG with graphic LCD and phonocardiogram system design.

    PubMed

    Kara, Sadik; Kemaloğlu, Semra; Kirbaş, Samil

    2006-06-01

    Till today, many different ECG devices are made in developing countries. In this study, low cost, small size, portable LCD screen ECG device, and phonocardiograph were designed. With designed system, heart sounds that take synchronously with ECG signal are heard as sensitive. Improved system consist three units; Unit 1, ECG circuit, filter and amplifier structure. Unit 2, heart sound acquisition circuit. Unit 3, microcontroller, graphic LCD and ECG signal sending unit to computer. Our system can be used easily in different departments of the hospital, health institution and clinics, village clinic and also in houses because of its small size structure and other benefits. In this way, it is possible that to see ECG signal and hear heart sounds as synchronously and sensitively. In conclusion, heart sounds are heard on the part of both doctor and patient because sounds are given to environment with a tiny speaker. Thus, the patient knows and hears heart sounds him/herself and is acquainted by doctor about healthy condition.

  20. Electrocardiographic systems with reduced numbers of leads-synthesis of the 12-lead ECG.

    PubMed

    Tomašić, Ivan; Trobec, Roman

    2014-01-01

    Systems with reduced numbers of leads that can synthesize the 12-lead electrocardiogram (ECG) with an insignificant or a small loss of diagnostic information have been proposed. The advantage over standard 12-lead ECG systems is the smaller number of measurement sites (i.e., electrodes) and, consequently, fewer wires. In this paper, we review all the important systems with reduced numbers of leads together with the methodology for synthesizing the leads. The fundamental theoretical background necessary to understand the most important concepts related to the synthesis is included. The presented theoretical and experimental justifications for the synthesis show that it is not necessary to measure a large number of leads directly, because the standard 12-lead ECG and arbitrary additional leads can be synthesized. Various approaches to evaluating the synthesized 12-lead ECG are defined and explained, and a number of systems that synthesize 12-lead ECG are presented as they were introduced in the literature. We cover the developments and improvements from the 1940s to the present day. The systems are classified on the basis of the synthesis method used, the approach to the evaluation of the synthesized ECG (depending on the measurement sites used), and on the number and types of leads employed. Based on a detailed assessment of state-of-the-art systems, open problems and challenges are highlighted, while further developments of electrocardiographic systems are envisaged.

  1. Genetic algorithm for the optimization of features and neural networks in ECG signals classification

    PubMed Central

    Li, Hongqiang; Yuan, Danyang; Ma, Xiangdong; Cui, Dianyin; Cao, Lu

    2017-01-01

    Feature extraction and classification of electrocardiogram (ECG) signals are necessary for the automatic diagnosis of cardiac diseases. In this study, a novel method based on genetic algorithm-back propagation neural network (GA-BPNN) for classifying ECG signals with feature extraction using wavelet packet decomposition (WPD) is proposed. WPD combined with the statistical method is utilized to extract the effective features of ECG signals. The statistical features of the wavelet packet coefficients are calculated as the feature sets. GA is employed to decrease the dimensions of the feature sets and to optimize the weights and biases of the back propagation neural network (BPNN). Thereafter, the optimized BPNN classifier is applied to classify six types of ECG signals. In addition, an experimental platform is constructed for ECG signal acquisition to supply the ECG data for verifying the effectiveness of the proposed method. The GA-BPNN method with the MIT-BIH arrhythmia database achieved a dimension reduction of nearly 50% and produced good classification results with an accuracy of 97.78%. The experimental results based on the established acquisition platform indicated that the GA-BPNN method achieved a high classification accuracy of 99.33% and could be efficiently applied in the automatic identification of cardiac arrhythmias. PMID:28139677

  2. Self-organized neural network for the quality control of 12-lead ECG signals.

    PubMed

    Chen, Yun; Yang, Hui

    2012-09-01

    Telemedicine is very important for the timely delivery of health care to cardiovascular patients, especially those who live in the rural areas of developing countries. However, there are a number of uncertainty factors inherent to the mobile-phone-based recording of electrocardiogram (ECG) signals such as personnel with minimal training and other extraneous noises. PhysioNet organized a challenge in 2011 to develop efficient algorithms that can assess the ECG signal quality in telemedicine settings. This paper presents our efforts in this challenge to integrate multiscale recurrence analysis with a self-organizing map for controlling the ECG signal quality. As opposed to directly evaluating the 12-lead ECG, we utilize an information-preserving transform, i.e. Dower transform, to derive the 3-lead vectorcardiogram (VCG) from the 12-lead ECG in the first place. Secondly, we delineate the nonlinear and nonstationary characteristics underlying the 3-lead VCG signals into multiple time-frequency scales. Furthermore, a self-organizing map is trained, in both supervised and unsupervised ways, to identify the correlations between signal quality and multiscale recurrence features. The efficacy and robustness of this approach are validated using real-world ECG recordings available from PhysioNet. The average performance was demonstrated to be 95.25% for the training dataset and 90.0% for the independent test dataset with unknown labels.

  3. The clinical application of a PACS-dependent 12-lead ECG and image information system in E-medicine and telemedicine.

    PubMed

    Hsieh, Jui-Chien; Lo, Hsiu-Chiung

    2010-08-01

    This study presents a software technology to transform paper-based 12-lead electrocardiography (ECG) examination into (1) 12-lead ECG electronic diagnoses (e-diagnoses) and (2) mobile diagnoses (m-diagnoses) in emergency telemedicine. While Digital Imaging and Communications in Medicine (DICOM)-based images are commonly used in hospitals, the development of computerized 12-lead ECG is impeded by heterogeneous data formats of clinically used 12-lead ECG instrumentations, such as Standard Communications Protocol (SCP) ECG and Extensible Markup Language (XML) ECG. Additionally, there is no data link between clinically used 12-lead ECG instrumentations and mobile devices. To realize computerized 12-lead ECG examination procedures and ECG telemedicine, this study develops a DICOM-based 12-lead ECG information system capable of providing clinicians with medical images and waveform-based ECG diagnoses via Picture Archiving and Communication System (PACS). First, a waveform-based DICOM-ECG converter transforming clinically used SCP-ECG and XML-ECG to DICOM is applied to PACS for image- and waveform-based DICOM file manipulation. Second, a mobile Structured Query Language database communicating with PACS is installed in physicians' mobile phones so that they can retrieve images and waveform-based ECG ubiquitously. Clinical evaluations of this system indicated the following. First, this developed PACS-dependent 12-lead ECG information system improves 12-lead ECG management and interoperability. Second, this system enables the remote physicians to perform ubiquitous 12-lead ECG and image diagnoses, which enhances the efficiency of emergency telemedicine. These findings prove the effectiveness and usefulness of the PACS-dependent 12-lead ECG information system, which can be easily adopted in telemedicine.

  4. Toward full-chip prediction of yield-limiting contact patterning failure: correlation of simulated image parameters to advanced contact metrology metrics

    NASA Astrophysics Data System (ADS)

    Sturtevant, John L.; Chou, Dyiann

    2006-03-01

    Electrical failure due to incomplete contacts or vias has arisen as one of the primary modes of yield loss for 130 nm and below designs in manufacturing. Such failures are generally understood to arise from both random and systematic sources. The addition of redundant vias, where possible, has long been an accepted DFM practice for mitigating the impact of random defects. Incomplete vias are often characterized by having a diameter near the target dimension but a depth of less than 100% of target. As such, it is a difficult problem to diagnose and debug in-line, since bright and dark field optical inspection systems cannot typically distinguish between a closed, partially open and fully open contact. Advanced metrology systems have emerged in recent years to meet this challenge, but no perfect manufacturing solution has yet been identified for full field verification of all contacts. Voltage Contrast (VC) SEM metrology biases the wafer to directly measure electrical conductivity after fill / polish, and can therefore easily discern a lack of electrical connection to the underlying conductor caused by incomplete photo, etch, or fill processing. While an entire wafer can in principal be VC scanned, throughput limitations dictate very sparse sampling in manufacturing. SEM profile grading (PG) leverages the rich content of the secondary electron waveform to decipher information about the bottom of the contact. Several authors have demonstrated an excellent response of the Profile Grade to intentional defocus vectors. However, the SEM can only target discreet or single digit groupings of contacts, and therefore requires intelligent guidance to identify those contacts which are most prone to failure, enabling protection of the fab WIP. An a-priori knowledge of which specific contacts in a layout are most likely to fail would prove very useful for proactive inspection in manufacturing. Model based pre-manufacturing verification allows for such knowledge to be communicated

  5. Transform Domain Robust Variable Step Size Griffiths' Adaptive Algorithm for Noise Cancellation in ECG

    NASA Astrophysics Data System (ADS)

    Hegde, Veena; Deekshit, Ravishankar; Satyanarayana, P. S.

    2011-12-01

    The electrocardiogram (ECG) is widely used for diagnosis of heart diseases. Good quality of ECG is utilized by physicians for interpretation and identification of physiological and pathological phenomena. However, in real situations, ECG recordings are often corrupted by artifacts or noise. Noise severely limits the utility of the recorded ECG and thus needs to be removed, for better clinical evaluation. In the present paper a new noise cancellation technique is proposed for removal of random noise like muscle artifact from ECG signal. A transform domain robust variable step size Griffiths' LMS algorithm (TVGLMS) is proposed for noise cancellation. For the TVGLMS, the robust variable step size has been achieved by using the Griffiths' gradient which uses cross-correlation between the desired signal contaminated with observation or random noise and the input. The algorithm is discrete cosine transform (DCT) based and uses symmetric property of the signal to represent the signal in frequency domain with lesser number of frequency coefficients when compared to that of discrete Fourier transform (DFT). The algorithm is implemented for adaptive line enhancer (ALE) filter which extracts the ECG signal in a noisy environment using LMS filter adaptation. The proposed algorithm is found to have better convergence error/misadjustment when compared to that of ordinary transform domain LMS (TLMS) algorithm, both in the presence of white/colored observation noise. The reduction in convergence error achieved by the new algorithm with desired signal decomposition is found to be lower than that obtained without decomposition. The experimental results indicate that the proposed method is better than traditional adaptive filter using LMS algorithm in the aspects of retaining geometrical characteristics of ECG signal.

  6. A Wearable Context-Aware ECG Monitoring System Integrated with Built-in Kinematic Sensors of the Smartphone

    PubMed Central

    Miao, Fen; Cheng, Yayu; He, Yi; He, Qingyun; Li, Ye

    2015-01-01

    Continuously monitoring the ECG signals over hours combined with activity status is very important for preventing cardiovascular diseases. A traditional ECG holter is often inconvenient to carry because it has many electrodes attached to the chest and because it is heavy. This work proposes a wearable, low power context-aware ECG monitoring system integrated built-in kinetic sensors of the smartphone with a self-designed ECG sensor. The wearable ECG sensor is comprised of a fully integrated analog front-end (AFE), a commercial micro control unit (MCU), a secure digital (SD) card, and a Bluetooth module. The whole sensor is very small with a size of only 58 × 50 × 10 mm for wearable monitoring application due to the AFE design, and the total power dissipation in a full round of ECG acquisition is only 12.5 mW. With the help of built-in kinetic sensors of the smartphone, the proposed system can compute and recognize user’s physical activity, and thus provide context-aware information for the continuous ECG monitoring. The experimental results demonstrated the performance of proposed system in improving diagnosis accuracy for arrhythmias and identifying the most common abnormal ECG patterns in different activities. In conclusion, we provide a wearable, accurate and energy-efficient system for long-term and context-aware ECG monitoring without any extra cost on kinetic sensor design but with the help of the widespread smartphone. PMID:25996508

  7. Reduction of Motion Artifacts and Improvement of R Peak Detecting Accuracy Using Adjacent Non-Intrusive ECG Sensors

    PubMed Central

    Choi, Minho; Jeong, Jae Jin; Kim, Seung Hun; Kim, Sang Woo

    2016-01-01

    Non-intrusive electrocardiogram (ECG) monitoring has many advantages: easy to measure and apply in daily life. However, motion noise in the measured signal is the major problem of non-intrusive measurement. This paper proposes a method to reduce the noise and to detect the R peaks of ECG in a stable manner in a sitting arrangement using non-intrusive sensors. The method utilizes two capacitive ECG sensors (cECGs) to measure ECG, and another two cECGs located adjacent to the sensors for ECG are added to obtain the information on motion. Then, active noise cancellation technique and the motion information are used to reduce motion noise. To verify the proposed method, ECG was measured indoors and during driving, and the accuracy of the detected R peaks was compared. After applying the method, the sum of sensitivity and positive predictivity increased 8.39% on average and 26.26% maximally in the data. Based on the results, it was confirmed that the motion noise was reduced and that more reliable R peak positions could be obtained by the proposed method. The robustness of the new ECG measurement method will elicit benefits to various health care systems that require noninvasive heart rate or heart rate variability measurements. PMID:27196910

  8. An integrated healthcare information system for end-to-end standardized exchange and homogeneous management of digital ECG formats.

    PubMed

    Trigo, Jesús Daniel; Martínez, Ignacio; Alesanco, Alvaro; Kollmann, Alexander; Escayola, Javier; Hayn, Dieter; Schreier, Günter; García, José

    2012-07-01

    This paper investigates the application of the enterprise information system (EIS) paradigm to standardized cardiovascular condition monitoring. There are many specifications in cardiology, particularly in the ECG standardization arena. The existence of ECG formats, however, does not guarantee the implementation of homogeneous, standardized solutions for ECG management. In fact, hospital management services need to cope with various ECG formats and, moreover, several different visualization applications. This heterogeneity hampers the normalization of integrated, standardized healthcare information systems, hence the need for finding an appropriate combination of ECG formats and a suitable EIS-based software architecture that enables standardized exchange and homogeneous management of ECG formats. Determining such a combination is one objective of this paper. The second aim is to design and develop the integrated healthcare information system that satisfies the requirements posed by the previous determination. The ECG formats selected include ISO/IEEE11073, Standard Communications Protocol for Computer-Assisted Electrocardiography, and an ECG ontology. The EIS-enabling techniques and technologies selected include web services, simple object access protocol, extensible markup language, or business process execution language. Such a selection ensures the standardized exchange of ECGs within, or across, healthcare information systems while providing modularity and accessibility.

  9. Online digital filter and QRS detector applicable in low resource ECG monitoring systems.

    PubMed

    Tabakov, Serafim; Iliev, Ivo; Krasteva, Vessela

    2008-11-01

    The present work describes fast computation methods for real-time digital filtration and QRS detection, both applicable in autonomous personal ECG systems for long-term monitoring. Since such devices work under considerable artifacts of intensive body and electrode movements, the input filtering should provide high-quality ECG signals supporting the accurate ECG interpretation. In this respect, we propose a combined high-pass and power-line interference rejection filter, introducing the simple principle of averaging of samples with a predefined distance between them. In our implementation (sampling frequency of 250 Hz), we applied averaging over 17 samples distanced by 10 samples (Filter10x17), thus realizing a comb filter with a zero at 50 Hz and high-pass cut-off at 1.1 Hz. Filter10x17 affords very fast filtering procedure at the price of minimal computing resources. Another benefit concerns the small ECG distortions introduced by the filter, providing its powerful application in the preprocessing module of diagnostic systems analyzing the ECG morphology. Filter10x17 does not attenuate the QRS amplitude, or introduce significant ST-segment elevation/depression. The filter output produces a constant error, leading to uniform shifting of the entire P-QRS-T segment toward about 5% of the R-peak amplitude. Tests with standardized ECG signals proved that Filter10x17 is capable to remove very strong baseline wanderings, and to fully suppress 50 Hz interferences. By changing the number of the averaged samples and the distance between them, a filter design with different cut-off and zero frequency could be easily achieved. The real-time QRS detector is designed with simplified computations over single channel, low-resolution ECGs. It relies on simple evaluations of amplitudes and slopes, including history of their mean values estimated over the preceding beats, smart adjustable thresholds, as well as linear logical rules for identification of the R-peaks in real

  10. ECG pattern in reverse takotsubo cardiomyopathy demonstrated in 5 cases with intracranial hemorrhage.

    PubMed

    Elikowski, Waldemar; Małek-Elikowska, Małgorzata; Kudliński, Bartosz; Skrzywanek, Paweł; Smól, Sławomir; Rzymski, Stanisław

    2016-09-29

    In typical takotsubo cardiomyopathy (TC) apical transient left ventricular dysfunction with concomitant ECG changes mimicking acute anterior myocardial infarction can be observed. Reverse TC (RTC) characterized by contractile disturbances in all basal and often simultaneous mid-ventricular segments is definitely less frequent. ECG pattern of RTC is less known. The authors present ECG findings in 5 cases of RTC in course of intracranial hemorrhage (ICH); 3 patients were diagnosed with subarachnoid hemorrhage (SAH) and the other two with intracerebral hemorrhage or subdural posttraumatic hematoma. In all patients, initial ECG appearance was dominated by ST segment depression in inferior leads (II, III, avF) and/or lateral leads (V4-6). In 4 patients, concurrent ST segment elevation in avR and avL leads was seen, additionally 4 patients had low QRS voltage in high lateral leads (I, avL). Potential normalization of these changes did not influence the patient`s survival. In one woman, immediately before death, early repolarization was recorded. In subjects with an increased risk of TC, for example in intracranial hemorrhage, particularly in SAH, the ECG abnormalities presented may indicate a need for further search of its atypical echocardiographic variants.

  11. ECG changes of cardiac origin in elderly patients with traumatic brain injury

    PubMed Central

    Hashemian, Amir Masoud; Ahmadi, Koorosh; Taherinia, Ali; Sharifi, Mohamad Davood; Ramezani, Javad; Jazayeri, Seyed Behzad; Saadat, Soheil; Rahimi-Movaghar, Vafa

    2015-01-01

    Background: Simultaneous electrocardiographic (ECG) changes are seen in hemorrhagic brain events even in the absence of associated myocardial infarction (MI). This study was designed to assess the role of ECG changes to predict true MI in patients with hemorrhagic brain trauma. Methods: Data of 153 patients with traumatic brain injury and concomitant ECG changes were recorded. Enzyme study was performed for the patients, and a cardiologist confirmed the diagnosis of MI. Results: Overall, 83 females and 70 males older than 50 years of age were enrolled in the study. The most common type of hemorrhagic brain event was subarachnoid hemorrhage, and the most common ECG change was an inverted T wave. MI was confirmed in 15 (9.8%) patients. Patients with intracranial hemorrhage had significantly (p= 0.023) higher rates of associated MI than other types of brain hemorrhages. ST segment elevation was found to have a positive predictive value of 71.4% in males and 25% in females in terms of diagnosing a true MI associated with hemorrhagic brain events. Conclusion: Although simultaneous cardiac changes are seen after sympathetic over- activity in brain hemorrhages, regular ECG screening of elder patients with traumatic brain injury is suggested, particularly in patients with intracranial hemorrhages. PMID:26913269

  12. Wearable technology and ECG processing for fall risk assessment, prevention and detection.

    PubMed

    Melillo, Paolo; Castaldo, Rossana; Sannino, Giovanna; Orrico, Ada; de Pietro, Giuseppe; Pecchia, Leandro

    2015-01-01

    Falls represent one of the most common causes of injury-related morbidity and mortality in later life. Subjects with cardiovascular disorders (e.g., related to autonomic dysfunctions and postural hypotension) are at higher risk of falling. Autonomic dysfunctions increasing the risk of falling in the short and mid-term could be assessed by Heart Rate Variability (HRV) extracted by electrocardiograph (ECG). We developed three trials for assessing the usefulness of ECG monitoring using wearable devices for: risk assessment of falling in the next few weeks; prevention of imminent falls due to standing hypotension; and fall detection. Statistical and data-mining methods are adopted to develop classification and regression models, validated with the cross-validation approach. The first classifier based on HRV features enabled to identify future fallers among hypertensive patients with an accuracy of 72% (sensitivity: 51.1%, specificity: 80.2%). The regression model to predict falls due to orthostatic dropdown from HRV recorded before standing achieved an overall accuracy of 80% (sensitivity: 92%, specificity: 90%). Finally, the classifier to detect simulated falls using ECG achieved an accuracy of 77.3% (sensitivity: 81.8%, specificity: 72.7%). The evidence from these three studies showed that ECG monitoring and processing could achieve satisfactory performances compared to other system for risk assessment, fall prevention and detection. This is interesting as differently from other technologies actually employed to prevent falls, ECG is recommended for many other pathologies of later life and is more accepted by senior citizens.

  13. Discrete wavelet transform and singular value decomposition based ECG steganography for secured patient information transmission.

    PubMed

    Edward Jero, S; Ramu, Palaniappan; Ramakrishnan, S

    2014-10-01

    ECG Steganography provides secured transmission of secret information such as patient personal information through ECG signals. This paper proposes an approach that uses discrete wavelet transform to decompose signals and singular value decomposition (SVD) to embed the secret information into the decomposed ECG signal. The novelty of the proposed method is to embed the watermark using SVD into the two dimensional (2D) ECG image. The embedding of secret information in a selected sub band of the decomposed ECG is achieved by replacing the singular values of the decomposed cover image by the singular values of the secret data. The performance assessment of the proposed approach allows understanding the suitable sub-band to hide secret data and the signal degradation that will affect diagnosability. Performance is measured using metrics like Kullback-Leibler divergence (KL), percentage residual difference (PRD), peak signal to noise ratio (PSNR) and bit error rate (BER). A dynamic location selection approach for embedding the singular values is also discussed. The proposed approach is demonstrated on a MIT-BIH database and the observations validate that HH is the ideal sub-band to hide data. It is also observed that the signal degradation (less than 0.6%) is very less in the proposed approach even with the secret data being as large as the sub band size. So, it does not affect the diagnosability and is reliable to transmit patient information.

  14. Real-Time Online Monitoring of Electrocardiogram (ECG) using Very Low Cost for Developing Countries

    NASA Astrophysics Data System (ADS)

    Singh, Gavendra; Gupta, Varun; Sekharmantri, Anil Kumar; Gupta, Akash; Kumar, Pankaj

    2010-11-01

    An electrocardiogram or ECG (also known as EKG—abbreviated from the German word Elektro-Kardiographie), is an electrical recording of the heart and is used in the investigation of heart disease. `An electrocardiogram (ECG) is a graphic tracing of the electric current generated by the heart muscle during a heartbeat'. The electrocardiogram (ECG)/(EKG) is a surface measurement of the electrical potential generated by electrical activity in cardiac tissue. It has been used extensively in medicine sine its inventions in the early 1900' sand has been proven to be invaluable in various diagnostics applications such as the detection of irregular heartbeat patterns (i.e. fibrillation & arrhythmia), hearts murmurs (other abnormal sounds), tissue/structural damage (such as valve malfunction) and coronary artery blockage. In this paper we made a circuit network by using this circuit we can acquire an ECG signal of the heart electrical activity. This is one of the cheapest circuit to acquire ECG signal. It's whole cost around Rs.250/- only. Instrumentation amplifier AD620AN, notch filter, various resistances, capacitors, wires etc. are used to made this circuit.

  15. A stacked contractive denoising auto-encoder for ECG signal denoising.

    PubMed

    Xiong, Peng; Wang, Hongrui; Liu, Ming; Lin, Feng; Hou, Zengguang; Liu, Xiuling

    2016-12-01

    As a primary diagnostic tool for cardiac diseases, electrocardiogram (ECG) signals are often contaminated by various kinds of noise, such as baseline wander, electrode contact noise and motion artifacts. In this paper, we propose a contractive denoising technique to improve the performance of current denoising auto-encoders (DAEs) for ECG signal denoising. Based on the Frobenius norm of the Jacobean matrix for the learned features with respect to the input, we develop a stacked contractive denoising auto-encoder (CDAE) to build a deep neural network (DNN) for noise reduction, which can significantly improve the expression of ECG signals through multi-level feature extraction. The proposed method is evaluated on ECG signals from the bench-marker MIT-BIH Arrhythmia Database, and the noises come from the MIT-BIH noise stress test database. The experimental results show that the new CDAE algorithm performs better than the conventional ECG denoising method, specifically with more than 2.40 dB improvement in the signal-to-noise ratio (SNR) and nearly 0.075 to 0.350 improvements in the root mean square error (RMSE).

  16. Improved Clinical Risk Stratification in Patients with Long QT Syndrome? Novel Insights from Multi-Channel ECGs

    PubMed Central

    Samol, Alexander; Gönes, Mehmet; Zumhagen, Sven; Bruns, Hans-Jürgen; Paul, Matthias; Vahlhaus, Christian; Waltenberger, Johannes; Schulze-Bahr, Eric; Eckardt, Lars; Mönnig, Gerold

    2016-01-01

    Background We investigated whether multichannel ECG-recordings are useful to risk-stratify patients with congenital long-QT syndrome (LQTS) for risk of sudden cardiac death under optimized medical treatment. Methods In 34 LQTS-patients (11 male; age 31±13 years, QTc 478±51ms; LQT1 n = 8, LQT2 n = 15) we performed a standard 12-channel ECG and a 120-channel body surface potential mapping. The occurrence of clinical events (CE; syncope, torsade de pointes (TdP), sudden cardiac arrest (SCA)) was documented and correlated with different ECG-parameters in all lead positions. Results Seven patients developed TdP, four survived SCA and 12 experienced syncope. 12/34 had at least one CE. CE was associated with a longer QTc-interval (519±43ms vs. 458±42ms; p = 0.001), a lower T-wave integral (TWI) on the left upper chest (-1.2±74.4mV*ms vs. 63.0±29.7mV*ms; p = 0.001), a lower range of T-wave amplitude (TWA) in the region of chest lead V8 (0.10±0.08mV vs. 0.18±0.07mV; p = 0.008) and a longer T-peak-T-end time (TpTe) in lead V1 (98±23ms vs. 78±26ms; p = 0.04). Receiver-operating-characteristic (ROC) analyses revealed a sensitivity of 96% and a specificity of 75% (area under curve (AUC) 0.89±0.06, p = 0.001) at a cut-off value of 26.8mV*ms for prediction of CE by TWI, a sensitivity of 86% and a specificity of 83% at a cut-off value of 0.11mV (AUC 0.83±0.09, p = 0.002) for prediction of CE by TWA and a sensitivity of 83% and a specificity of 73% at a cut-off value of 87ms (AUC 0.80±0.07, p = 0.005) for prediction of CE by TpTe. Conclusions Occurrence of CE in LQTS-patients seems to be associated with a prolonged, low-amplitude T-wave. PMID:27379800

  17. Photo degradation of methyl orange an azo dye by advanced Fenton process using zero valent metallic iron: influence of various reaction parameters and its degradation mechanism.

    PubMed

    Gomathi Devi, L; Girish Kumar, S; Mohan Reddy, K; Munikrishnappa, C

    2009-05-30

    Advanced Fenton process (AFP) using zero valent metallic iron (ZVMI) is studied as a potential technique to degrade the azo dye in the aqueous medium. The influence of various reaction parameters like effect of iron dosage, concentration of H(2)O(2)/ammonium per sulfate (APS), initial dye concentration, effect of pH and the influence of radical scavenger are studied and optimum conditions are reported. The degradation rate decreased at higher iron dosages and also at higher oxidant concentrations due to the surface precipitation which deactivates the iron surface. The rate constant for the processes Fe(0)/UV and Fe(0)/APS/UV is twice compared to their respective Fe(0)/dark and Fe(0)/APS/dark processes. The rate constant for Fe(0)/H(2)O(2)/UV process is four times higher than Fe(0)/H(2)O(2)/dark process. The increase in the efficiency of Fe(0)/UV process is attributed to the cleavage of stable iron complexes which produces Fe(2+) ions that participates in cyclic Fenton mechanism for the generation of hydroxyl radicals. The increase in the efficiency of Fe(0)/APS/UV or H(2)O(2) compared to dark process is due to continuous generation of hydroxyl radicals and also due to the frequent photo reduction of Fe(3+) ions to Fe(2+) ions. Though H(2)O(2) is a better oxidant than APS in all respects, but it is more susceptible to deactivation by hydroxyl radical scavengers. The decrease in the rate constant in the presence of hydroxyl radical scavenger is more for H(2)O(2) than APS. Iron powder retains its recycling efficiency better in the presence of H(2)O(2) than APS. The decrease in the degradation rate in the presence of APS as an oxidant is due to the fact that generation of free radicals on iron surface is slower compared to H(2)O(2). Also, the excess acidity provided by APS retards the degradation rate as excess H(+) ions acts as hydroxyl radical scavenger. The degradation of Methyl Orange (MO) using Fe(0) is an acid driven process shows higher efficiency at pH 3. The

  18. Prolonged corrected QT interval is predictive of future stroke events even in subjects without ECG-diagnosed left ventricular hypertrophy.

    PubMed

    Ishikawa, Joji; Ishikawa, Shizukiyo; Kario, Kazuomi

    2015-03-01

    We attempted to evaluate whether subjects who exhibit prolonged corrected QT (QTc) interval (≥440 ms in men and ≥460 ms in women) on ECG, with and without ECG-diagnosed left ventricular hypertrophy (ECG-LVH; Cornell product, ≥244 mV×ms), are at increased risk of stroke. Among the 10 643 subjects, there were a total of 375 stroke events during the follow-up period (128.7±28.1 months; 114 142 person-years). The subjects with prolonged QTc interval (hazard ratio, 2.13; 95% confidence interval, 1.22-3.73) had an increased risk of stroke even after adjustment for ECG-LVH (hazard ratio, 1.71; 95% confidence interval, 1.22-2.40). When we stratified the subjects into those with neither a prolonged QTc interval nor ECG-LVH, those with a prolonged QTc interval but without ECG-LVH, and those with ECG-LVH, multivariate-adjusted Cox proportional hazards analysis demonstrated that the subjects with prolonged QTc intervals but not ECG-LVH (1.2% of all subjects; incidence, 10.7%; hazard ratio, 2.70, 95% confidence interval, 1.48-4.94) and those with ECG-LVH (incidence, 7.9%; hazard ratio, 1.83; 95% confidence interval, 1.31-2.57) had an increased risk of stroke events, compared with those with neither a prolonged QTc interval nor ECG-LVH. In conclusion, prolonged QTc interval was associated with stroke risk even among patients without ECG-LVH in the general population.

  19. Towards the clinical use of concentric electrodes in ECG recordings: influence of ring dimensions and electrode position

    NASA Astrophysics Data System (ADS)

    Prats-Boluda, G.; Ye-Lin, Y.; Bueno-Barrachina, JM; Rodriguez de Sanabria, R.; Garcia-Casado, J.

    2016-02-01

    To overcome the limited spatial resolution of standard 12-lead ECG recordings, concentric ring electrodes (CRE) have been proposed to provide valuable data for the diagnosis of a wide range of cardiac abnormalities, including infarction and arrhythmia. Although theoretical studies indicate that the dimensions of the CRE regulate the depth of the electric dipoles sensed by these electrodes, this has not been experimentally confirmed. The aim of this work was to analyze the influence of CRE dimensions and position of a wireless multi-CRE sensor node on the cardiac signal recorded. For this, four wireless multichannel ECG recording nodes based on flexible multi-ring electrodes were placed at positions CMV1 (position comparable to V1), CMV2, CMV4R and CMV5; each node providing three bipolar concentric ECG signals (BC-ECG). Standard 12-lead ECG and 12 BC-ECG signals were recorded in 29 volunteers. The results revealed that a ring with an outer diameter of 33.5 mm achieves a balance between the ease-of-use and spatial resolution of smaller electrodes and improved detectability and higher amplitudes of signals from larger ring electrodes. Although a standard 12-lead ECG outperforms BC-ECC recordings in detectability of cardiac waves, if the relative amplitude of the wave is also considered, BC-ECG at CMV1 proved superior at picking up atrial activity. In fact, in most of the BC-ECG signals picked up at CMV1, P1 and P2 atrial activity waves were more clearly identified than in simultaneous 12-Lead ECG signals. Likewise, BC-ECG signals revealed higher spatial resolution in detecting anomalous electrical activity in local regions, such as impaired intraventricular driving, or atrioventricular blocks. Finally, the wireless multi-CRE sensor node provides enhanced comfort and handling to both patient and clinician over wired systems.

  20. A Novel SCN5A Mutation Associated with Drug Induced Brugada Type ECG

    PubMed Central

    Turker, Isik; Makiyama, Takeru; Vatta, Matteo; Itoh, Hideki; Ueyama, Takeshi; Shimizu, Akihiko

    2016-01-01

    Background Class IC antiarrhythmic agents may induce acquired forms of Brugada Syndrome. We have identified a novel mutation in SCN5A, the gene that encodes the α-subunit of the human cardiac sodium channel (hNav1.5), in a patient who exhibited Brugada- type ECG changes during pharmacotherapy of atrial arrhythmias. Objective To assess whether the novel mutation p.V1328M can cause drug induced Brugada Syndrome. Methods Administration of pilsicainide, a class IC antiarrhythmic agent, caused Brugada- type ST elevation in a 66-year-old Japanese male who presented with paroxysmal atrial fibrillation (PAF), type I atrial flutter and inducible ventricular fibrillation (VF) during electrophysiological study. Genetic screening using direct sequencing identified a novel SCN5A variant, p.V1328M. Electrophysiological parameters of WT and p.V1328M and their effects on drug pharmacokinetics were studied using the patch-clamp method. Results Whole-cell sodium current densities were similar for WT and p.V1328M channels. While p.V1328M mutation did not affect the voltage-dependence of the activation kinetics, it caused a positive shift of voltage-dependent steady-state inactivation by 7 mV. The tonic block in the presence of pilsicainide was similar in WT and p.V1328M, when sodium currents were induced by a low frequency pulse protocol (q15s). On the contrary, p.V1328M mutation enhanced pilsicainide induced use-dependent block at 2 Hz. (Ki: WT, 35.8 μM; V1328M, 19.3 μM). Conclusion Our study suggests that a subclinical SCN5A mutation, p.V1328M, might predispose individuals harboring it to drug-induced Brugada Syndrome. PMID:27560382

  1. Pseudo-ischaemic ECG in a patient with amyotrophic lateral sclerosis surviving for a decade

    PubMed Central

    Zhang, Jian; Yang, Shi-Wei; Wang, Zheng; Wei, Guang-Ru; Zhou, Yu-Jie

    2012-01-01

    A 58-year-old female with no history of heart disease was admitted to our hospital for abnormal ECG mimicking myocardial ischaemia. The ECG revealed persistent T-wave inversion in almost all leads, especially in precordial leads V2–V6. The patient had no complaints of chest pain, chest distress, short of breath or other atypical myocardial ischaemia symptoms. She had a history of amyotrophic lateral sclerosis (ALS) with a disease course more than 20 years. Examinations help rule out other diseases causing persistent T-wave inversion. Importantly, cardiac catheterisation showed nearly normal coronary arteries that could rule out myocardial ischaemia. Accordingly, the authors presumed that the pseudo-ischaemic ECG was associated with ALS in this patient. The findings of the present case provide new evidence that autonomic nervous system may involve in the pathophysiological progress of ALS. PMID:22665549

  2. ECG-based PICC tip verification system: an evaluation 5 years on.

    PubMed

    Oliver, Gemma; Jones, Matt

    2016-10-27

    In 2011, the vascular access team at East Kent Hospitals University NHS Foundation Trust safely and successfully incorporated the use of electrocardiogram (ECG) guidance technology for verification of peripherally inserted central catheters (PICC) tip placement into their practice. This study, 5 years on, compared the strengths and limitations of using this ECG method with the previous gold-standard of post-procedural chest X-ray. The study was undertaken using an embedded case study approach, and the cost, accuracy and efficiency of both systems were evaluated and compared. Using ECG to confirm PICC tip position was found to be cheaper, quicker and more accurate than post-procedural chest X-ray.

  3. Scuba diving, acute left anterior descending artery occlusion and normal ECG.

    PubMed

    Doll, Sébastien Xavier; Rigamonti, Fabio; Roffi, Marco; Noble, Stéphane

    2013-01-31

    We report the case of an acute proximal occlusion of the left anterior descending coronary (LAD) artery following a scuba diving decompression accident and associated with normal ECG. Following uneventful thromboaspiration and coronary stenting, the patient was discharged on day 4 with secondary preventative therapies. A transthoracic echocardiography performed at this point showed a complete recovery compared with an initial localised akinesia involving the anterior and apical portion of the left ventricle upon admission. This case highlights that significant acute coronary lesions involving the LAD can occur without any ECG anomaly. The presence of acute and persistent angina associated with troponin elevation should prompt physicians to consider coronary angiography without delay, independently of the ECG results.

  4. High-calcium exposure to frog heart: a simple model representing hypercalcemia-induced ECG abnormalities.

    PubMed

    Kazama, Itsuro

    2017-01-20

    By simply adding a high concentration of calcium solution to the surface of the bullfrog heart, we reproduced electrocardiogram (ECG) abnormalities representing those observed in hypercalcemia, such as Osborn waves and shortening of the QT interval. The rise in extracellular calcium concentration may have activated the outward potassium currents during phase 3 of the action potential, and thus decreased its duration. In addition to the known decrease in the duration of phase 2, such changes in phase 3 were also likely to contribute to the shortening of the QT interval. The dual recordings of the action potential in cardiomyocytes and the ECG waves enabled us to demonstrate the mechanisms of ECG abnormalities induced by hypercalcemia.

  5. A hierarchical method for removal of baseline drift from biomedical signals: application in ECG analysis.

    PubMed

    Luo, Yurong; Hargraves, Rosalyn H; Belle, Ashwin; Bai, Ou; Qi, Xuguang; Ward, Kevin R; Pfaffenberger, Michael Paul; Najarian, Kayvan

    2013-01-01

    Noise can compromise the extraction of some fundamental and important features from biomedical signals and hence prohibit accurate analysis of these signals. Baseline wander in electrocardiogram (ECG) signals is one such example, which can be caused by factors such as respiration, variations in electrode impedance, and excessive body movements. Unless baseline wander is effectively removed, the accuracy of any feature extracted from the ECG, such as timing and duration of the ST-segment, is compromised. This paper approaches this filtering task from a novel standpoint by assuming that the ECG baseline wander comes from an independent and unknown source. The technique utilizes a hierarchical method including a blind source separation (BSS) step, in particular independent component analysis, to eliminate the effect of the baseline wander. We examine the specifics of the components causing the baseline wander and the factors that affect the separation process. Experimental results reveal the superiority of the proposed algorithm in removing the baseline wander.

  6. Labview Based ECG Patient Monitoring System for Cardiovascular Patient Using SMTP Technology.

    PubMed

    Singh, Om Prakash; Mekonnen, Dawit; Malarvili, M B

    2015-01-01

    This paper leads to developing a Labview based ECG patient monitoring system for cardiovascular patient using Simple Mail Transfer Protocol technology. The designed device has been divided into three parts. First part is ECG amplifier circuit, built using instrumentation amplifier (AD620) followed by signal conditioning circuit with the operation amplifier (lm741). Secondly, the DAQ card is used to convert the analog signal into digital form for the further process. Furthermore, the data has been processed in Labview where the digital filter techniques have been implemented to remove the noise from the acquired signal. After processing, the algorithm was developed to calculate the heart rate and to analyze the arrhythmia condition. Finally, SMTP technology has been added in our work to make device more communicative and much more cost-effective solution in telemedicine technology which has been key-problem to realize the telediagnosis and monitoring of ECG signals. The technology also can be easily implemented over already existing Internet.

  7. Using an injection signal to reduce motion artifacts in capacitive ECG measurements.

    PubMed

    Serteyn, Aline; Vullings, Rik; Meftah, Mohammed; Bergmans, Jan

    2013-01-01

    Capacitive electrodes are a promising alternative to the conventional adhesive ECG electrodes. They provide more comfort to the patient when integrated in everyday objects (e.g. beds or seats) for long-term monitoring. However, the application of such electrodes is limited by their high sensitivity to motion artifacts. Artifacts caused by variation of the coupling capacitance are studied here. An injection signal is proposed to track these variations in real-time. An adaptive filter then estimates the motion artifact and cancels it from the recorded ECG. The amplitude of the motion artifact is reduced in average by 29 dB in simulation and by 20 dB in a lab environment. Our method has the advantages that it is able to reduce motion artifacts occurring in the frequency band of the ECG and that it does not require knowledge about the measurement system.

  8. Comparison of JADE and canonical correlation analysis for ECG de-noising.

    PubMed

    Kuzilek, Jakub; Kremen, Vaclav; Lhotska, Lenka

    2014-01-01

    This paper explores differences between two methods for blind source separation within frame of ECG de-noising. First method is joint approximate diagonalization of eigenmatrices, which is based on estimation of fourth order cross-cummulant tensor and its diagonalization. Second one is the statistical method known as canonical correlation analysis, which is based on estimation of correlation matrices between two multidimensional variables. Both methods were used within method, which combines the blind source separation algorithm with decision tree. The evaluation was made on large database of 382 long-term ECG signals and the results were examined. Biggest difference was found in results of 50 Hz power line interference where the CCA algorithm completely failed. Thus main power of CCA lies in estimation of unstructured noise within ECG. JADE algorithm has larger computational complexity thus the CCA perfomed faster when estimating the components.

  9. Powerline interference reduction in ECG signals using empirical wavelet transform and adaptive filtering.

    PubMed

    Singh, Omkar; Sunkaria, Ramesh Kumar

    2015-01-01

    Separating an information-bearing signal from the background noise is a general problem in signal processing. In a clinical environment during acquisition of an electrocardiogram (ECG) signal, The ECG signal is corrupted by various noise sources such as powerline interference (PLI), baseline wander and muscle artifacts. This paper presents novel methods for reduction of powerline interference in ECG signals using empirical wavelet transform (EWT) and adaptive filtering. The proposed methods are compared with the empirical mode decomposition (EMD) based PLI cancellation methods. A total of six methods for PLI reduction based on EMD and EWT are analysed and their results are presented in this paper. The EWT-based de-noising methods have less computational complexity and are more efficient as compared with the EMD-based de-noising methods.

  10. Wavelet-Based Watermarking and Compression for ECG Signals with Verification Evaluation

    PubMed Central

    Tseng, Kuo-Kun; He, Xialong; Kung, Woon-Man; Chen, Shuo-Tsung; Liao, Minghong; Huang, Huang-Nan

    2014-01-01

    In the current open society and with the growth of human rights, people are more and more concerned about the privacy of their information and other important data. This study makes use of electrocardiography (ECG) data in order to protect individual information. An ECG signal can not only be used to analyze disease, but also to provide crucial biometric information for identification and authentication. In this study, we propose a new idea of integrating electrocardiogram watermarking and compression approach, which has never been researched before. ECG watermarking can ensure the confidentiality and reliability of a user's data while reducing the amount of data. In the evaluation, we apply the embedding capacity, bit error rate (BER), signal-to-noise ratio (SNR), compression ratio (CR), and compressed-signal to noise ratio (CNR) methods to assess the proposed algorithm. After comprehensive evaluation the final results show that our algorithm is robust and feasible. PMID:24566636

  11. An ultra-high input impedance ECG amplifier for long-term monitoring of athletes

    PubMed Central

    Gargiulo, Gaetano; Bifulco, Paolo; Cesarelli, Mario; Ruffo, Mariano; Romano, Maria; Calvo, Rafael A; Jin, Craig; van Schaik, André

    2010-01-01

    We present a new, low-power electrocardiogram (ECG) recording system with an ultra-high input impedance that enables the use of long-lasting, dry electrodes. The system incorporates a low-power Bluetooth module for wireless connectivity and is designed to be suitable for long-term monitoring during daily activities. The new system using dry electrodes was compared with a clinically approved ECG reference system using gelled Ag/AgCl electrodes and performance was found to be equivalent. In addition, the system was used to monitor an athlete during several physical tasks, and a good quality ECG was obtained in all cases, including when the athlete was totally submerged in fresh water. PMID:22915916

  12. Application of the Max-Lloyd quantizer for ECG compression in diving mammals.

    PubMed

    Rodríguez, M; Ayala, A; Rodríguez, S; Rosa, F; Díaz-González, Mario

    2004-01-01

    This article presents a practical implementation of an ECG compression algorithm using a Max-Lloyd quantizer, to optimize the low resources of an ECG acquisition and transmission system (telemetry system) for dolphins and human divers. The algorithm scheme is based on a first-order differential pulse code modulation (DPCM) and uses a Max-Lloyd quantizer to code the difference between the current and predicted samples. The use of the non-uniform quantizer instead of a uniform quantizer improves the percent root mean-square difference (PRD), thereby producing a low distortion in the reconstructed signals. Due to its low computational complexity, the compression process can be accomplished on-line during the ECG acquisition process.

  13. High-calcium exposure to frog heart: a simple model representing hypercalcemia-induced ECG abnormalities

    PubMed Central

    KAZAMA, Itsuro

    2016-01-01

    By simply adding a high concentration of calcium solution to the surface of the bullfrog heart, we reproduced electrocardiogram (ECG) abnormalities representing those observed in hypercalcemia, such as Osborn waves and shortening of the QT interval. The rise in extracellular calcium concentration may have activated the outward potassium currents during phase 3 of the action potential, and thus decreased its duration. In addition to the known decrease in the duration of phase 2, such changes in phase 3 were also likely to contribute to the shortening of the QT interval. The dual recordings of the action potential in cardiomyocytes and the ECG waves enabled us to demonstrate the mechanisms of ECG abnormalities induced by hypercalcemia. PMID:27773880

  14. An ECG storage and retrieval system embedded in client server HIS utilizing object-oriented DB.

    PubMed

    Wang, C; Ohe, K; Sakurai, T; Nagase, T; Kaihara, S

    1996-02-01

    In the University of Tokyo Hospital, the improved client server HIS has been applied to clinical practice and physicians can order prescription, laboratory examination, ECG examination and radiographic examination, etc. directly by themselves and read results of these examinations, except medical signal waves, schema and image, on UNIX workstations. Recently, we designed and developed an ECG storage and retrieval system embedded in the client server HIS utilizing object-oriented database to take the first step in dealing with digitized signal, schema and image data and show waves, graphics, and images directly to physicians by the client server HIS. The system was developed based on object-oriented analysis and design, and implemented with object-oriented database management system (OODMS) and C++ programming language. In this paper, we describe the ECG data model, functions of the storage and retrieval system, features of user interface and the result of its implementation in the HIS.

  15. Semisupervised ECG Ventricular Beat Classification With Novelty Detection Based on Switching Kalman Filters.

    PubMed

    Oster, Julien; Behar, Joachim; Sayadi, Omid; Nemati, Shamim; Johnson, Alistair E W; Clifford, Gari D

    2015-09-01

    Automatic processing and accurate diagnosis of pathological electrocardiogram (ECG) signals remains a challenge. As long-term ECG recordings continue to increase in prevalence, driven partly by the ease of remote monitoring technology usage, the need to automate ECG analysis continues to grow. In previous studies, a model-based ECG filtering approach to ECG data from healthy subjects has been applied to facilitate accurate online filtering and analysis of physiological signals. We propose an extension of this approach, which models not only normal and ventricular heartbeats, but also morphologies not previously encountered. A switching Kalman filter approach is introduced to enable the automatic selection of the most likely mode (beat type), while simultaneously filtering the signal using appropriate prior knowledge. Novelty detection is also made possible by incorporating a third mode for the detection of unknown (not previously observed) morphologies, and denoted as X-factor. This new approach is compared to state-of-the-art techniques for the ventricular heartbeat classification in the MIT-BIH arrhythmia and Incart databases. F1 scores of 98.3% and 99.5% were found on each database, respectively, which are superior to other published algorithms' results reported on the same databases. Only 3% of all the beats were discarded as X-factor, and the majority of these beats contained high levels of noise. The proposed technique demonstrates accurate beat classification in the presence of previously unseen (and unlearned) morphologies and noise, and provides an automated method for morphological analysis of arbitrary (unknown) ECG leads.

  16. Non-ECG-Gated Myocardial Perfusion MRI Using Continuous Magnetization-Driven Radial Sampling

    PubMed Central

    Sharif, Behzad; Dharmakumar, Rohan; Arsanjani, Reza; Thomson, Louise; Merz, C. Noel Bairey; Berman, Daniel S.; Li, Debiao

    2014-01-01

    Purpose Establishing a high-resolution non-ECG-gated first-pass perfusion (FPP) cardiac MRI technique may improve accessibility and diagnostic capability of FPP imaging. We propose a non-ECG-gated FPP imaging technique using continuous magnetization-driven golden-angle radial acquisition. The main purpose of this preliminary study is to evaluate whether, in the simple case of single-slice 2D imaging, adequate myocardial contrast can be obtained for accurate visualization of hypoperfused territories in the setting of myocardial ischemia. Methods A T1-weighted pulse sequence with continuous golden-angle radial sampling was developed for non-ECG-gated FPP imaging. A sliding-window scheme with no temporal acceleration was used to reconstruct 8 frames/second. Canines were imaged at 3T with and without coronary stenosis using the proposed scheme and a conventional magnetization-prepared ECG-gated FPP method. Results Our studies showed that the proposed non-ECG-gated method is capable of generating high-resolution (1.7×1.7×6 mm3) artifact-free FPP images of a single slice at high heart rates (92±21 beats/minute), while matching the performance of conventional FPP imaging in terms of hypoperfused-to-normal myocardial contrast-to-noise ratio (proposed: 5.18±0.70, conventional: 4.88±0.43). Furthermore, the detected perfusion defect areas were consistent with the conventional FPP images. Conclusion Non-ECG-gated FPP imaging using optimized continuous golden-angle radial acquisition achieves desirable image quality (i.e., adequate myocardial contrast, high spatial resolution, and minimal artifacts) in the setting of ischemia. PMID:24443160

  17. A computer based wireless system for online acquisition, monitoring and digital processing of ECG waveforms.

    PubMed

    Bansal, Dipali; Khan, Munna; Salhan, Ashok K

    2009-04-01

    Various ECG instruments have addressed a wide variety of clinical and technical issues. However, there is still scope for improvement in them particularly in the area of their susceptibility to noise, lack of universal connectivity and off-line processing. A prototype system has been developed that caters to these limitations. It includes an analog system and a FM transceiver pair interfaced through sound port of the computer. The real time acquired data is viewed and filtered using MATLAB software. The ECG system described captures the bio-signal faithfully in real time wireless mode with minimum noise and has universal connectivity.

  18. Skin-electrode impedance measurement during ECG acquisition: method’s validation

    NASA Astrophysics Data System (ADS)

    Casal, Leonardo; La Mura, Guillermo

    2016-04-01

    Skm-electrode impedance measurement can provide valuable information prior. dunng and post electrocardiographic (ECG) or electroencephalographs (EEG) acquisitions. In this work we validate a method for skm-electrode impedance measurement using test circuits with known resistance and capacitor values, at different frequencies for injected excitation current. Finally the method is successfully used for impedance measurement during ECG acquisition on a subject usmg 125 Hz and 6 nA square wave excitation signal at instrumentation amplifier mput. The method can be used for many electrodes configuration.

  19. ECG Denoising Using Marginalized Particle Extended Kalman Filter with an Automatic Particle Weighting Strategy.

    PubMed

    Hesar, Hamed; Mohebbi, Maryam

    2016-06-20

    In this paper a model-based Bayesian filtering framework called the "marginalized particle-extended Kalman filter (MP-EKF) algorithm" is proposed for electrocardiogram (ECG) denoising. This algorithm does not have the extended Kalman filter (EKF) shortcoming in handling non-Gaussian nonstationary situations because of its nonlinear framework. In addition, it has less computational complexity compared with particle filter. This filter improves ECG denoising performance by implementing marginalized particle filter framework while reducing its computational complexity using EKF framework. An automatic particle weighting strategy is also proposed here that controls the reliance of our framework to the acquired measurements. We evaluated the proposed filter on several normal ECGs selected from MIT-BIH normal sinus rhythm database. To do so, artificial white Gaussian and colored noises as well as nonstationary real muscle artifact (MA) noise over a range of low SNRs from 10 to -5 dB were added to these normal ECG segments. The benchmark methods were the EKF and extended Kalman smoother (EKS) algorithms which are the first model-based Bayesian algorithms introduced in the field of ECG denoising. From SNR viewpoint, the experiments showed that in the presence of Gaussian white noise, the proposed framework outperforms the EKF and EKS algorithms in lower input SNRs where the measurements and state model are not reliable. Owing to its nonlinear framework and particle weighting strategy, the proposed algorithm attained better results at all input SNRs in non-Gaussian non-stationary situations (such as presence of pink noise, brown noise, and real muscle artifacts). In addition, the impact of the proposed filtering method on the distortion of diagnostic features of the ECG was investigated and compared with EKF/EKS methods using an ECG diagnostic distortion measure called the "Multi-Scale Entropy Based Weighted Distortion Measure" or MSEWPRD. The results revealed that our

  20. A 54-year-old woman with premature ventricular complexes and a rapidly changing ECG

    PubMed Central

    Bencharif, Sarah; Leung, Lawrence

    2015-01-01

    Premature ventricular complexes (PVCs) are common findings in asymptomatic participants during ECG recordings. While most PVCs are treated conservatively, some patients may develop adverse cardiac events needing further investigations and definitive ablation by radiofrequency. Spectral strain ultrasonography has demonstrated ventricular dysfunction as a sequel to high burden PVCs, but the exact underlying pathophysiology is still uncertain. Cohort studies have associated PVCs with increased risks for overall cardiovascular morbidity and mortality, and yet consensus is still lacking for threshold in treating PVCs. Our case is that of a 54-year-old woman with an unusual bradycardiac presentation of PVCs and an ECG that changed rapidly within minutes. PMID:25827918

  1. A portable ECG monitoring device with Bluetooth and Holter capabilities for telemedicine applications.

    PubMed

    Lucani, Daniel; Cataldo, Giancarlos; Cruz, Julio; Villegas, Guillermo; Wong, Sara

    2006-01-01

    A prototype of a portable ECG-monitoring device has been developed for clinical and non-clinical environments as part of a telemedicine system to provide remote and continuous surveillance of patients. The device can acquire, store and/or transmit ECG signals to computer-based platforms or specially configured access points (AP) with Intranet/Internet capabilities in order to reach remote monitoring stations. Acquired data can be stored in a flash memory card in FAT16 format for later recovery, or transmitted via Bluetooth or USB to a local station or AP. This data acquisition module (DAM) operates in two modes: Holter and on-line transmission.

  2. Real time reconstruction of quasiperiodic multi parameter physiological signals

    NASA Astrophysics Data System (ADS)

    Ganeshapillai, Gartheeban; Guttag, John

    2012-12-01

    A modern intensive care unit (ICU) has automated analysis systems that depend on continuous uninterrupted real time monitoring of physiological signals such as electrocardiogram (ECG), arterial blood pressure (ABP), and photo-plethysmogram (PPG). These signals are often corrupted by noise, artifacts, and missing data. We present an automated learning framework for real time reconstruction of corrupted multi-parameter nonstationary quasiperiodic physiological signals. The key idea is to learn a patient-specific model of the relationships between signals, and then reconstruct corrupted segments using the information available in correlated signals. We evaluated our method on MIT-BIH arrhythmia data, a two-channel ECG dataset with many clinically significant arrhythmias, and on the CinC challenge 2010 data, a multi-parameter dataset containing ECG, ABP, and PPG. For each, we evaluated both the residual distance between the original signals and the reconstructed signals, and the performance of a heartbeat classifier on a reconstructed ECG signal. At an SNR of 0 dB, the average residual distance on the CinC data was roughly 3% of the energy in the signal, and on the arrhythmia database it was roughly 16%. The difference is attributable to the large amount of diversity in the arrhythmia database. Remarkably, despite the relatively high residual difference, the classification accuracy on the arrhythmia database was still 98%, indicating that our method restored the physiologically important aspects of the signal.

  3. Whole-Chest 64-MDCT of Emergency Department Patients with Nonspecific Chest Pain: Radiation Dose and Coronary Artery Image Quality with Prospective ECG Triggering Versus Retrospective ECG Gating

    PubMed Central

    Shuman, William P.; Branch, Kelley R.; May, Janet M.; Mitsumori, Lee M.; Strote, Jared N.; Warren, Bill H.; Dubinsky, Theodore J.; Lockhart, David W.; Caldwell, James H.

    2012-01-01

    Objective The purpose of this study was to compare the patient radiation dose and coronary artery image quality of long-z-axis whole-chest 64-MDCT performed with retrospective ECG gating with those of CT performed with prospective ECG triggering in the evaluation of emergency department patients with nonspecific chest pain. Subjects and Methods Consecutively registered emergency department patients with nonspecific low-to-moderate-risk chest pain underwent whole-chest CT with retrospective gating (n = 41) or prospective triggering (n = 31). Effective patient radiation doses were estimated and compared by use of unpaired Student's t tests. Two reviewers independently scored the quality of images of the coronary arteries, and the scores were compared by use of ordinal logistic regression. Results Age, heart rate, body mass index, and z-axis coverage were not statistically different between the two groups. For retrospective gating, the mean effective radiation dose was 31.8 ± 5.1 mSv; for prospective triggering, the mean effective radiation dose was 9.2 ± 2.2 mSv (prospective triggering 71% lower, p < 0.001). Two of 512 segments imaged with retrospective gating were nonevaluable (0.4%), and two of 394 segments imaged with prospective triggering were nonevaluable (0.5%). Prospectively triggered images were 2.2 (95% CI, 1.1–4.5) times as likely as retrospectively gated images to receive a high image quality score for each segment after adjustment for segment differences (p < 0.05). Conclusion For long-z-axis whole-chest 64-MDCT of emergency department patients with nonspecific chest pain, use of prospective ECG triggering may result in substantially lower patient radiation doses and better coronary artery image quality than is achieved with retrospective ECG gating. PMID:19457832

  4. Non-contrast-enhanced MR angiography using 3D ECG-synchronized half-Fourier fast spin echo.

    PubMed

    Miyazaki, M; Sugiura, S; Tateishi, F; Wada, H; Kassai, Y; Abe, H

    2000-11-01

    A non-contrast-enhanced three-dimensional (3D) magnetic resonance angiography (MRA) technique, which acquires images in a reasonably short scanning time and requires no contrast agent, is developed. An electrocardiographically (ECG) synchronized 3D half-Fourier fast spin-echo (FSE) technique with an appropriate ECG delay time for every slice encoding in 3D terms was used to examine the thoracic and iliac regions in 16 healthy volunteers at both 0.5 and 1.5 T. Prior to each 3D fresh blood imaging (FBI) experiment, an ECG preparation (ECG-prep) scan was acquired, and an appropriate ECG triggering time was selected for 3D FBI acquisition to optimize visualization of the vessel of interest. In the thoracic and abdominal regions, good-quality 3D MRA images were obtained. Furthermore, the weighted subtraction of two images in different phases provides contrast enhancement between arteries and veins.

  5. Fusion beat in patients with heart failure treated with left ventricular pacing: may ECG morphology relate to mechanical synchrony? A pilot study

    PubMed Central

    Gianfranchi, Lorella; Bettiol, Katia; Sassone, Biagio; Verlato, Roberto; Corbucci, Giorgio; Alboni, Paolo

    2008-01-01

    Background Electrical fusion between left ventricular pacing and spontaneous right ventricular activation is considered the key to resynchronisation in sinus rhythm patients treated with single-site left ventricular pacing. Aim Use of QRS morphology to optimize device programming in patients with heart failure (HF), sinus rhythm (SR), left bundle branch block (LBBB), treated with single-site left ventricular pacing. Methods and Results We defined the "fusion band" (FB) as the range of AV intervals within which surface ECG showed an intermediate morphology between the native LBBB and the fully paced right bundle branch block patterns. Twenty-four patients were enrolled. Echo-derived parameters were collected in the FB and compared with the basal LBBB condition. Velocity time integral and ejection time did not improve significantly. Diastolic filling time, ejection fraction and myocardial performance index showed a statistically significant improvement in the FB. Interventricular delay and mitral regurgitation progressively and significantly decreased as AV delay shortened in the FB. The tissue Doppler asynchrony index (Ts-SD-12-ejection) showed a non significant decreasing trend in the FB. The indications provided by the tested parameters were mostly concordant in that part of the FB corresponding to the shortest AV intervals. Conclusion Using ECG criteria based on the FB may constitute an attractive option for a safe, simple and rapid optimization of resynchronization therapy in patients with HF, SR and LBBB. PMID:18167164

  6. High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging

    NASA Technical Reports Server (NTRS)

    Rahman, Atiar

    2006-01-01

    Background: Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). Methods and Results: 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (P<0.001). Conclusions: Analysis of 12-lead HF QRS ECG is highly sensitive and specific for detecting ischemic perfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.

  7. High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging

    NASA Technical Reports Server (NTRS)

    2004-01-01

    Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (P less than 0.00l). Analysis of 12-lead HF QRS ECG is highly sensitive and specific for detecting ischemic perfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.

  8. ECG Rhythm Analysis with Expert and Learner-Generated Schemas in Novice Learners

    ERIC Educational Resources Information Center

    Blissett, Sarah; Cavalcanti, Rodrigo; Sibbald, Matthew

    2015-01-01

    Although instruction using expert-generated schemas is associated with higher diagnostic performance, implementation is resource intensive. Learner-generated schemas are an alternative, but may be limited by increases in cognitive load. We compared expert- and learner-generated schemas for learning ECG rhythm interpretation on diagnostic accuracy,…

  9. A modular low-complexity ECG delineation algorithm for real-time embedded systems.

    PubMed

    Bote, Jose Manuel; Recas, Joaquin; Rincon, Francisco; Atienza, David; Hermida, Roman

    2017-02-17

    This work presents a new modular and lowcomplexity algorithm for the delineation of the different ECG waves (QRS, P and T peaks, onsets and end). Involving a reduced number of operations per second and having a small memory footprint, this algorithm is intended to perform realtime delineation on resource-constrained embedded systems. The modular design allows the algorithm to automatically adjust the delineation quality in run time to a wide range of modes and sampling rates, from a Ultra-low power mode when no arrhythmia is detected, in which the ECG is sampled at low frequency, to a complete High-accuracy delineation mode in which the ECG is sampled at high frequency and all the ECG fiducial points are detected, in case of arrhythmia. The delineation algorithm has been adjusted using the QT database, providing very high sensitivity and positive predictivity, and validated with the MIT database. The errors in the delineation of all the fiducial points are below the tolerances given by the Common Standards for Electrocardiography (CSE) committee in the High-accuracy mode, except for the P wave onset, for which the algorithm is above the agreed tolerances by only a fraction of the sample duration. The computational load for the ultra-low-power 8-MHz TI MSP430 series microcontroller ranges from 0.2 to 8.5% according to the mode used.

  10. Consistent quality control in ECG compression by means of direct metrics.

    PubMed

    Hernando-Ramiro, Carlos; Blanco-Velasco, Manuel; Lovisolo, Lisandro; Cruz-Roldán, Fernando

    2015-09-01

    The aim of electrocardiogram (ECG) compression is to reduce the amount of data as much as possible while preserving the significant information for diagnosis. Objective metrics that are derived directly from the signal are suitable for controlling the quality of the compressed ECGs in practical applications. Many approaches have employed figures of merit based on the percentage root mean square difference (PRD) for this purpose. The benefits and drawbacks of the PRD measures, along with other metrics for quality assessment in ECG compression, are analysed in this work. We propose the use of the root mean square error (RMSE) for quality control because it provides a clearer and more stable idea about how much the retrieved ECG waveform, which is the reference signal for establishing diagnosis, separates from the original. For this reason, the RMSE is applied here as the target metric in a thresholding algorithm that relies on the retained energy. A state of the art compressor based on this approach, and its PRD-based counterpart, are implemented to test the actual capabilities of the proposed technique. Both compression schemes are employed in several experiments with the whole MIT-BIH Arrhythmia Database to assess both global and local signal distortion. The results show that, using the RMSE for quality control, the distortion of the reconstructed signal is better controlled without reducing the compression ratio.

  11. Application of computerized exercise ECG digitization. Interpretation in large clinical trials.

    PubMed

    Caralis, D G; Shaw, L; Bilgere, B; Younis, L; Stocke, K; Wiens, R D; Chaitman, B R

    1992-04-01

    The authors report on a semiautomated program that incorporates both visual identification of fiducial points and digital determination of the ST-segment at 60 ms and 80 ms from the J point, ST slope, changes in R wave, and baseline drift. The off-line program can enhance the accuracy of detecting electrocardiographic (ECG) changes, as well as reproducibility of the exercise and postexercise ECG, as a marker of myocardial ischemia. The analysis program is written in Microsoft QuickBASIC 2.0 for an IBM personal computer interfaced to a Summagraphics mm1201 microgrid II digitizer. The program consists of the following components: (1) alphanumeric data entry, (2) ECG wave form digitization, (2) calculation of test results, (4) physician overread, and (5) editor function for remeasurements. This computerized exercise ECG digitization-interpretation program is accurate and reproducible for the quantitative assessment of ST changes and requires minimal time allotment for physician overread. The program is suitable for analysis and interpretation of large volumes of exercise tests in multicenter clinical trials and is currently utilized in the TIMI II, TIMI III, and BARI studies sponsored by the National Institutes of Health.

  12. Wireless Sensor-Based Smart-Clothing Platform for ECG Monitoring.

    PubMed

    Wang, Jie; Lin, Chung-Chih; Yu, Yan-Shuo; Yu, Tsang-Chu

    2015-01-01

    The goal of this study is to use wireless sensor technologies to develop a smart clothes service platform for health monitoring. Our platform consists of smart clothes, a sensor node, a gateway server, and a health cloud. The smart clothes have fabric electrodes to detect electrocardiography (ECG) signals. The sensor node improves the accuracy of QRS complexes detection by morphology analysis and reduces power consumption by the power-saving transmission functionality. The gateway server provides a reconfigurable finite state machine (RFSM) software architecture for abnormal ECG detection to support online updating. Most normal ECG can be filtered out, and the abnormal ECG is further analyzed in the health cloud. Three experiments are conducted to evaluate the platform's performance. The results demonstrate that the signal-to-noise ratio (SNR) of the smart clothes exceeds 37 dB, which is within the "very good signal" interval. The average of the QRS sensitivity and positive prediction is above 99.5%. Power-saving transmission is reduced by nearly 1980 times the power consumption in the best-case analysis.

  13. The new FAA national automated ECG network: some aviation medical examiner experiences.

    PubMed

    Beers, K N; Mohler, S R

    1991-01-01

    The Federal Aviation Administration (FAA) has required, since August 1, 1987, that aviation medical examiners (AMEs) transmit by telephone all electrocardiograms (ECGs) necessary for airman "Class I" medical certification. This relatively new airman certification requirement is centralized at the Civil Aeromedical Institute (CAMI) in Oklahoma City. In calendar year 1989, the FAA received 69,000 electronically transmitted electrocardiograms. CAMI uses Marquette Electronics software to interpret the ECG signals that are received from multi-channel equipment. The single-channel transmitted ECGs are hand screened at present. The FAA "automated" screening program is unique among governmental airman medical certification programs throughout the world. This paper presents, for potential future users, the authors' experiences with the new airman automated electrocardiographic certification requirement, and covers positive and negative features involved in the implementation and operation of the program. We conclude that while the new FAA automated ECG screening program has satisfactorily replaced the former "physician-intensive" manual screening process, the new system increases the AME's equipment and operation costs. These are passed on to the airman who is seeking certification.

  14. Switching Kalman filter based methods for apnea bradycardia detection from ECG signals.

    PubMed

    Montazeri Ghahjaverestan, Nasim; Shamsollahi, Mohammad B; Ge, Di; Hernández, Alfredo I

    2015-09-01

    Apnea bradycardia (AB) is an outcome of apnea occurrence in preterm infants and is an observable phenomenon in cardiovascular signals. Early detection of apnea in infants under monitoring is a critical challenge for the early intervention of nurses. In this paper, we introduce two switching Kalman filter (SKF) based methods for AB detection using electrocardiogram (ECG) signal.The first SKF model uses McSharry's ECG dynamical model integrated in two Kalman filter (KF) models trained for normal and AB intervals. Whereas the second SKF model is established by using only the RR sequence extracted from ECG and two AR models to be fitted in normal and AB intervals. In both SKF approaches, a discrete state variable called a switch is considered that chooses one of the models (corresponding to normal and AB) during the inference phase. According to the probability of each model indicated by this switch, the model with larger probability determines the observation label at each time instant.It is shown that the method based on ECG dynamical model can be effectively used for AB detection. The detection performance is evaluated by comparing statistical metrics and the amount of time taken to detect AB compared with the annotated onset. The results demonstrate the superiority of this method, with sensitivity and specificity 94.74[Formula: see text] and 94.17[Formula: see text], respectively. The presented approaches may therefore serve as an effective algorithm for monitoring neonates suffering from AB.

  15. Extracting the respiration cycle lengths from ECG signal recorded with bed sheet electrodes

    NASA Astrophysics Data System (ADS)

    Vehkaoja, A.; Peltokangas, M.; Lekkala, J.

    2013-09-01

    A method for recognizing the respiration cycle lengths from the electrocardiographic (ECG) signal recorded with textile electrodes that are attached to a bed sheet is proposed. The method uses two features extracted from the ECG that are affected by the respiration: respiratory sinus arrhythmia and the amplitude of the R-peaks. The proposed method was tested in one hour long recordings with ten healthy young adults. A relative mean absolute error of 5.6 % was achieved when the algorithm was able to provide a result for approximately 40 % of the time. 90 % of the values were within 0.5 s and 97 % within 1 s from the reference respiration value. In addition to the instantaneous respiration cycle lengths, also the mean values during 1 and 5 minutes epochs are calculated. The effect of the ECG signal source is evaluated by calculating the result also from the simultaneously recorded reference ECG signal. The acquired respiration information can be used in the estimation of sleep quality and the detection of sleep disorders.

  16. Cancelling ECG Artifacts in EEG Using a Modified Independent Component Analysis Approach

    NASA Astrophysics Data System (ADS)

    Devuyst, Stéphanie; Dutoit, Thierry; Stenuit, Patricia; Kerkhofs, Myriam; Stanus, Etienne

    2008-12-01

    We introduce a new automatic method to eliminate electrocardiogram (ECG) noise in an electroencephalogram (EEG) or electrooculogram (EOG). It is based on a modification of the independent component analysis (ICA) algorithm which gives promising results while using only a single-channel electroencephalogram (or electrooculogram) and the ECG. To check the effectiveness of our approach, we compared it with other methods, that is, ensemble average subtraction (EAS) and adaptive filtering (AF). Tests were carried out on simulated data obtained by addition of a filtered ECG on a visually clean original EEG and on real data made up of 10 excerpts of polysomnographic (PSG) sleep recordings containing ECG artifacts and other typical artifacts (e.g., movement, sweat, respiration, etc.). We found that our modified ICA algorithm had the most promising performance on simulated data since it presented the minimal root mean-squared error. Furthermore, using real data, we noted that this algorithm was the most robust to various waveforms of cardiac interference and to the presence of other artifacts, with a correction rate of 91.0%, against 83.5% for EAS and 83.1% for AF.

  17. Unusual QRS morphology on ECG: a rare condition and an interesting response to pacing.

    PubMed

    Gula, Lorne J; Eckart, Robert E; Klein, George J; Peralta, Adelqui

    2005-08-01

    We present the interesting case of a young man with borderline wide QRS complexes noted on electrocardiogram (ECG). The diagnosis of an unusual form of preexcitation was reached using observations from intracardiac tracings at electrophysiology study. Atrial pacing consistently resulted in further widening of the first conducted QRS complex, and the physiology underlying this unusual finding is explored.

  18. An ultra-low power (ULP) bandage-type ECG sensor for efficient cardiac disease management.

    PubMed

    Shin, Kunsoo; Park, G G; Kim, J P; Lee, T H; Ko, B H; Kim, Y H

    2013-01-01

    This paper proposed an ultra-low power bandage-type ECG sensor (the size: 76 × 34 × 3 (mm(3)) and the power consumption: 1 mW) which allows for a continuous and real-time monitoring of a user's ECG signals over 24h during daily activities. For its compact size and lower power consumption, we designed the analog front-end, the SRP (Samsung Reconfigurable Processor) based DSP of 30 uW/MHz, and the ULP wireless RF of 1 nJ/bit. Also, to tackle motion artifacts(MA), a MA monitoring technique based on the HCP (Half-cell Potential) is proposed which resulted in the high correlation between the MA and the HCP, the correlation coefficient of 0.75 ± 0.18. To assess its feasibility and validity as a wearable health monitor, we performed the comparison of two ECG signals recorded form it and a conventional Holter device. As a result, the performance of the former is a little lower as compared with the latter, although showing no statistical significant difference (the quality of the signal: 94.3% vs 99.4%; the accuracy of arrhythmia detection: 93.7% vs 98.7%). With those results, it has been confirmed that it can be used as a wearable health monitor due to its comfortability, its long operation lifetime and the good quality of the measured ECG signal.

  19. FPGA-core defibrillator using wavelet-fuzzy ECG arrhythmia classification.

    PubMed

    Nambakhsh, Mohammad; Tavakoli, Vahid; Sahba, Nima

    2008-01-01

    An electrocardiogram (ECG) feature extraction and classification system has been developed and evaluated using Quartus II 7.1 belong to Altera Ltd. In wavelet domain QRS complexes were detected and each complex was used to locate the peaks of the individual waves. Then, fuzzy classifier block used these features to classify ECG beats. Three types of arrhythmias and abnormalities were detected using the procedure. The completed algorithm was embedded into Field Programmable Gate Array (FPGA). The completed prototype was tested through software-generated signals, in which test scenarios covering several kinds of ECG signals on MIT-BIH Database. For the purpose of feeding signals into the FPGA, a software was designed to read signal files and import them to the LPT port of computer that was connected to FPGA. From the results, it was achieved that the proposed prototype could do real time monitoring of ECG signal for arrhythmia detection. We also implemented algorithm in a sequential structure device like AVR microcontroller with 16 MHZ clock for the same purpose. External clock of FPGA is 50 MHZ and by utilizing of Phase Lock Loop (PLL) component inside device, it was possible to increase the clock up to 1.2 GHZ in internal blocks. Final results compare speed and cost of resource usage in both devices. It shows that in cost of more resource usage, FPGA provides higher speed of computation; because FPGA makes the algorithm able to compute most parts in parallel manner.

  20. Stability of computer ECG amplitude measurements in the presence of noise. The CSE Working Party.

    PubMed

    Zywietz, C; Willems, J L; Arnaud, P; van Bemmel, J H; Degani, R; Macfarlane, P W

    1990-02-01

    An important feature of an ECG analysis program is its ability to provide reliable measurements under various operating conditions, e.g., on noise-free and noisy ECGs. Therefore, within the European cooperative project "Common Standards For Quantitative Electrocardiography" (CSE), the accuracy and stability of ECG measurements obtained by several computer programs has been compared. To investigate the stability of measurements two sets of 10 ECGs with and without seven different high- and low-frequency types of noise--altogether 160 electrocardiograms and 160 vectorcardiograms--have been analyzed by eight electrocardiographic and five vectorcardiographic computer programs. The stability of measurement was tested with respect to results obtained for the noise-free recordings. In a previous paper, the influence of noise on wave boundary recognition has been reported. In the present paper, the effect of noise on amplitude measurements and on problems of waveform definitions within the QRS complex are described. The results indicate that programs analyzing an averaged beat exhibit less variability than programs which measure every complex or a selected beat. Comparability and stability of measurements could be improved if a standardized procedure for amplitude references were to be introduced. In addition, the stability of QRS waveform labelling could be improved if waveforms' minimum amplitude and duration were to be validated against the noise level which itself should be determined by a standardized procedure.

  1. Food and Insulin Effect on QT/QTC Interval of ECG

    ClinicalTrials.gov

    2014-08-19

    Effects of Different Meals on the QT/QTc Interval; Insulin and Oral Hypoglycemic [Antidiabetic] Drugs Causing Adverse Effects in Therapeutic Use; C-Peptide Effects on the QT/QTc Interval; Moxifloxacin ECG Profile in Fed and Fasted State; Japanese vs. Caucasian TQT Comparison

  2. Wireless Sensor-Based Smart-Clothing Platform for ECG Monitoring

    PubMed Central

    Wang, Jie; Lin, Chung-Chih; Yu, Yan-Shuo; Yu, Tsang-Chu

    2015-01-01

    The goal of this study is to use wireless sensor technologies to develop a smart clothes service platform for health monitoring. Our platform consists of smart clothes, a sensor node, a gateway server, and a health cloud. The smart clothes have fabric electrodes to detect electrocardiography (ECG) signals. The sensor node improves the accuracy of QRS complexes detection by morphology analysis and reduces power consumption by the power-saving transmission functionality. The gateway server provides a reconfigurable finite state machine (RFSM) software architecture for abnormal ECG detection to support online updating. Most normal ECG can be filtered out, and the abnormal ECG is further analyzed in the health cloud. Three experiments are conducted to evaluate the platform's performance. The results demonstrate that the signal-to-noise ratio (SNR) of the smart clothes exceeds 37 dB, which is within the “very good signal” interval. The average of the QRS sensitivity and positive prediction is above 99.5%. Power-saving transmission is reduced by nearly 1980 times the power consumption in the best-case analysis. PMID:26640512

  3. ECG monitoring of heart failure and pilot load/overload by the Vesla seat pad.

    PubMed

    Sem-Jacobsen, C W

    1976-04-01

    Heart failure has caused sudden incapacitation of pilots in command of commerical airliners. These fatal episodes have occurred in connection with takeoffs and landings, and have resulted in incidents as well as major accidents in which more than 300 people have been killed. Coronary attack may be verified later at autopsy. Sudden cardiac arrest or serious episodes, such as ventricular tachycardia, usually cannot be detected at autopsy. A number of accidents due to unknown reasons or to "pilot error" can be due to, and some probably are, cardiac breakdown. It is today possible, with the Vesla Seat Pad, to monitor the pilot's ECG. The Vesla Seat Pad is a device for biomedical monitoring of ECG signals from human subjects without attachment to the subjects of any leads or sensor devices. The Vesla pad on which a human subject may rest, requires no power source. It is capable of obtaining appropriate ECG signals, transmitted to the pad through the medium of the subject's perspiration, for monitoring the subject's heart action. ECG signals, together with other data, can be electronically processed and used to warn the co-pilot and tower of impending hazard. The "dead man's button" with an OVERLOAD warning system could greatly, when taken into use, improve flying safety.

  4. A mobile phone-based ecg and heart sound monitoring system - biomed 2011.

    PubMed

    Iwamoto, Junichi; Ogawa, Hidekuni; Maki, Hiromichi; Yonezawa, Yoshiharu; Hahn, Allen W; Caldwell, W Morton

    2011-01-01

    We have developed a telemedicine system to monitor a patient’s electrocardiogram (ECG) and heart sounds (PCG) during daily activity. The complete system, consisting of an ECG recorder, an accelerometer and a 2.4 GHz low power mobile phone, is mounted on three chest sensing electrodes. The accelerometer records the PCG produced by closing of the mitral and aortic valves (S1 and S2). The sampled ECG and PCG are stored in the system for two minutes and continuously updated. When a patient feels heart discomfort such as angina or an arrhythmia, he/she pushes the data transmission switch on the system. The ECG and PCG for the next two minutes are stored in the system, and then the system then sends the four minutes of stored data directly to a hospital server computer via the 1.9 GHz low power mobile phone. These data are stored on the server and then downloaded to the physician’s Java configured mobile phone. The physician can then check the patient’s cardiac condition, regardless of patient or physician locations, and then take appropriate actions.

  5. Evaluation of Digital Compressed Sensing for Real-Time Wireless ECG System with Bluetooth low Energy.

    PubMed

    Wang, Yishan; Doleschel, Sammy; Wunderlich, Ralf; Heinen, Stefan

    2016-07-01

    In this paper, a wearable and wireless ECG system is firstly designed with Bluetooth Low Energy (BLE). It can detect 3-lead ECG signals and is completely wireless. Secondly the digital Compressed Sensing (CS) is implemented to increase the energy efficiency of wireless ECG sensor. Different sparsifying basis, various compression ratio (CR) and several reconstruction algorithms are simulated and discussed. Finally the reconstruction is done by the android application (App) on smartphone to display the signal in real time. The power efficiency is measured and compared with the system without CS. The optimum satisfying basis built by 3-level decomposed db4 wavelet coefficients, 1-bit Bernoulli random matrix and the most suitable reconstruction algorithm are selected by the simulations and applied on the sensor node and App. The signal is successfully reconstructed and displayed on the App of smartphone. Battery life of sensor node is extended from 55 h to 67 h. The presented wireless ECG system with CS can significantly extend the battery life by 22 %. With the compact characteristic and long term working time, the system provides a feasible solution for the long term homecare utilization.

  6. Manual and semi-automatic registration vs retrospective ECG gating for correction of cardiac motion

    NASA Astrophysics Data System (ADS)

    So, Aaron; Adam, Vincent; Acharya, Kishor; Pan, Tin-Su; Lee, Ting-Yim

    2003-05-01

    A manual and a semi-automatic image registration method were compared with retrospective ECG (rECG) gating to correct for cardiac motion in myocardial perfusion (MBF) measurement. 5 beagles were used in 11 experiments. For each experiment a 30 s cine CT scan of the heart was acquired after contrast injection. For the manual method, a reference end-diastole (ED) image was selected from the first cardiac cycle. ED images in subsequent cardiac cycles were manually selected to match the shape of the reference ED image. For each cardiac cycle in the semi-automatic method, the image with the maximum area and the most similar shape to the selected image of the previous cardiac cycle was chosen as ED image. MBFs were calculated from the images registered by the three methods and compared. The averages of the difference of MBFmanual and MBFsemi-auto and MBFrECG in the lateral free wall of LV were 3.6 and 3.4 ml/min/100g respectively. The corresponding standard deviations from the mean were 9.1 and 28.3 ml/min/100g respectively. We concluded from these preliminary results that image registration methods were better than rECG gating for correcting heart, which should facilitate more precise measurement of MBF.

  7. Effect of Heart Rate and Body Mass Index on the Interscan and Interobserver Variability of Coronary Artery Calcium Scoring at Prospective ECG-Triggered 64-Slice CT

    PubMed Central

    Matsuura, Noriaki; Yamamoto, Hideya; Kiguchi, Masao; Fujioka, Chikako; Kitagawa, Toshiro; Ito, Katsuhide

    2009-01-01

    Objective To test the effects of heart rate, body mass index (BMI) and noise level on interscan and interobserver variability of coronary artery calcium (CAC) scoring on a prospective electrocardiogram (ECG)-triggered 64-slice CT. Materials and Methods One hundred and ten patients (76 patients with CAC) were scanned twice on prospective ECG-triggered scans. The scan parameters included 120 kV, 82 mAs, a 2.5 mm thickness, and an acquisition center at 45% of the RR interval. The interscan and interobserver variability on the CAC scores (Agatston, volume, and mass) was calculated. The factors affecting the variability were determined by plotting it against heart rate, BMI, and noise level (defined as the standard deviation: SD). Results The estimated effective dose was 1.5 ± 0.2 mSv. The mean heart rate was 63 ± 12 bpm (range, 44-101 bpm). The patient BMIs were 24.5 ± 4.5 kg/m2 (range, 15.5-42.3 kg/m2). The mean and median interscan variabilities were 11% and 6%, respectively by volume, and 11% and 6%, respectively, by mass. Moreover, the mean and median of the algorithms were lower than the Agatston algorithm (16% and 9%, respectively). The mean and median interobserver variability was 10% and 4%, respectively (average of algorithms). The mean noise levels were 15 ± 4 Hounsfield unit (HU) (range, 8-25 HU). The interscan and interobserver variability was not correlated with heart rate, BMI, or noise level. Conclusion The interscan and interobserver variability of CAC on a prospective ECG-triggered 64-slice CT with high image quality and 45% of RR acquisition is not significantly affected by heart rate, BMI, or noise level. The volume or mass algorithms show reduced interscan variability compared to the Agatston scoring (p < 0.05). PMID:19568461

  8. Implementation and verification of an enhanced algorithm for the automatic computation of RR-interval series derived from 24 h 12-lead ECGs.

    PubMed

    Hagmair, Stefan; Braunisch, Matthias C; Bachler, Martin; Schmaderer, Christoph; Hasenau, Anna-Lena; Bauer, Axel; Rizas, Kostantinos D; Wassertheurer, Siegfried; Mayer, Christopher C

    2017-01-01

    An important tool in early diagnosis of cardiac dysfunctions is the analysis of electrocardiograms (ECGs) obtained from ambulatory long-term recordings. Heart rate variability (HRV) analysis became a significant tool for assessing the cardiac health. The usefulness of HRV assessment for the prediction of cardiovascular events in end-stage renal disease patients was previously reported. The aim of this work is to verify an enhanced algorithm to obtain an RR-interval time series in a fully automated manner. The multi-lead corrected R-peaks of each ECG lead are used for RR-series computation and the algorithm is verified by a comparison with manually reviewed reference RR-time series. Twenty-four hour 12-lead ECG recordings of 339 end-stage renal disease patients from the ISAR (rISk strAtification in end-stage Renal disease) study were used. Seven universal indicators were calculated to allow for a generalization of the comparison results. The median score of the indicator of synchronization, i.e. intraclass correlation coefficient, was 96.4% and the median of the root mean square error of the difference time series was 7.5 ms. The negligible error and high synchronization rate indicate high similarity and verified the agreement between the fully automated RR-interval series calculated with the AIT Multi-Lead ECGsolver and the reference time series. As a future perspective, HRV parameters calculated on this RR-time series can be evaluated in longitudinal studies to ensure clinical benefit.

  9. Acute chest pain in emergency room. Preliminary findings with 40-64-slice CT ECG-gated of the whole chest.

    PubMed

    Coche, E

    2007-01-01

    ECG-gated MDCT of the entire chest represents the latest technical advance in the diagnostic work-up of atypical chest pain. The authors report their preliminary experience with the use of 40 and 64-slice CT in the emergency room and recommend to study only patients with moderate likelihood of coronary artery disease. ECG-gated MDCT of the entire chest will be preferentially performed on 64-slice MDCT rather than 40-slice MDCT because it enable to reduce the scan time (18 seconds versus 28 seconds acquisition time), the volume of contrast medium (82 mL + 15 mL versus 97 mL + 15 mL of highly concentrated contrast agent for a patient of 70 kgs) and radiation exposure (17 mSv versus 19 mSv). Approximately 1500 to 2000 of images are produced and need to be analysed on a dedicated workstation by a radiologist expert in cardiac and thoracic disorders. At the present time, only a few studies exist in the literature showing some promising results but further large clinical studies are needed before to implement such sophisticated protocol in emergency room.

  10. An ECG-based Algorithm for the Automatic Identification of Autonomic Activations Associated with Cortical Arousal

    PubMed Central

    Basner, Mathias; Griefahn, Barbara; Müller, Uwe; Plath, Gernot; Samel, Alexander

    2007-01-01

    Objectives: EEG arousals are associated with autonomic activations. Visual EEG arousal scoring is time consuming and suffers from low interobserver agreement. We hypothesized that information on changes in heart rate alone suffice to predict the occurrence of cortical arousal. Methods: Two visual AASM EEG arousal scorings of 56 healthy subject nights (mean age 37.0 ± 12.8 years, 26 male) were obtained. For each of 5 heartbeats following the onset of 3581 consensus EEG arousals and of an equal number of control conditions, differences to a moving median were calculated and used to estimate likelihood ratios (LRs) for 10 categories of heartbeat differences. Comparable to 5 consecutive diagnostic tests, these LRs were used to calculate the probability of heart rate responses being associated with cortical arousals. Results: EEG and ECG arousal indexes agreed well across a wide range of decision thresholds, resulting in a receiver operating characteristic (ROC) with an area under the curve of 0.91. For the decision threshold chosen for the final analyses, a sensitivity of 68.1% and a specificity of 95.2% were obtained. ECG and EEG arousal indexes were poorly correlated (r = 0.19, P <0.001, ICC = 0.186), which could in part be attributed to 3 outliers. The Bland-Altman plot showed an unbiased estimation of EEG arousal indexes by ECG arousal indexes with a standard deviation of ± 7.9 arousals per hour sleep. In about two-thirds of all cases, ECG arousal scoring was matched by at least one (22.2%) or by both (42.5%) of the visual scorings. Sensitivity of the algorithm increased with increasing duration of EEG arousals. The ECG algorithm was also successfully validated with 30 different nights of 10 subjects (mean age 35.3 ▯ 13.6 years, 5 male). Conclusions: In its current version, the ECG algorithm cannot replace visual EEG arousal scoring. Sensitivity for detecting <10-s EEG arousals needs to be improved. However, in a nonclinical population, it may be valuable to

  11. Agreement between clinical and portable EMG/ECG diagnosis of sleep bruxism.

    PubMed

    Castroflorio, T; Bargellini, A; Rossini, G; Cugliari, G; Deregibus, A; Manfredini, D

    2015-10-01

    The aim of this study was to compare clinical sleep bruxism (SB) diagnosis with an instrumental diagnosis obtained with a device providing electromyography/electrocardiography (EMG/ECG) recordings. Forty-five (N = 45) subjects (19 males and 26 females, mean age 28 ± 11 years) were selected among patients referring to the Gnathology Unit of the Dental School of the University of Torino. An expert clinician assessed the presence of SB based on the presence of one or more signs/symptoms (i.e., transient jaw muscle pain in the morning, muscle fatigue at awakening, presence of tooth wear, masseter hypertrophy). Furthermore, all participants underwent an instrumental recording at home with a portable device (Bruxoff; OT Bioelettronica, Torino, Italy) allowing a simultaneous recording of EMG signals from both the masseter muscles as well as heart frequency. Statistical procedures were performed with the software Statistical Package for the Social Science v. 20.0 (SPSS 20.0; IBM, Milan, Italy). Based on the EMG/ECG analysis, 26 subjects (11 males, 15 females, mean age 28 ± 10 years) were diagnosed as sleep bruxers, whilst 19 subjects (7 males, 12 females, mean age 30 ± 10 years) were diagnosed as non-bruxers. The correlation between the clinical and EMG/ECG SB diagnoses was low (ϕ value = 0.250), with a 62.2% agreement (28/45 subjects) between the two approaches (kappa = 0.248). Assuming instrumental EMG/ECG diagnosis as the standard of reference for definite SB diagnosis in this investigation, the false-positive and false-negative rates were unacceptable for all clinical signs/symptoms. In conclusion, findings from clinical assessment are not related with SB diagnosis performed with a portable EMG/ECG recorder.

  12. A machine learning approach to multi-level ECG signal quality classification.

    PubMed

    Li, Qiao; Rajagopalan, Cadathur; Clifford, Gari D

    2014-12-01

    Current electrocardiogram (ECG) signal quality assessment studies have aimed to provide a two-level classification: clean or noisy. However, clinical usage demands more specific noise level classification for varying applications. This work outlines a five-level ECG signal quality classification algorithm. A total of 13 signal quality metrics were derived from segments of ECG waveforms, which were labeled by experts. A support vector machine (SVM) was trained to perform the classification and tested on a simulated dataset and was validated using data from the MIT-BIH arrhythmia database (MITDB). The simulated training and test datasets were created by selecting clean segments of the ECG in the 2011 PhysioNet/Computing in Cardiology Challenge database, and adding three types of real ECG noise at different signal-to-noise ratio (SNR) levels from the MIT-BIH Noise Stress Test Database (NSTDB). The MITDB was re-annotated for five levels of signal quality. Different combinations of the 13 metrics were trained and tested on the simulated datasets and the best combination that produced the highest classification accuracy was selected and validated on the MITDB. Performance was assessed using classification accuracy (Ac), and a single class overlap accuracy (OAc), which assumes that an individual type classified into an adjacent class is acceptable. An Ac of 80.26% and an OAc of 98.60% on the test set were obtained by selecting 10 metrics while 57.26% (Ac) and 94.23% (OAc) were the numbers for the unseen MITDB validation data without retraining. By performing the fivefold cross validation, an Ac of 88.07±0.32% and OAc of 99.34±0.07% were gained on the validation fold of MITDB.

  13. Changes in ischaemic ECG abnormalities and subsequent risk of cardiovascular disease

    PubMed Central

    Sawai, Takeshi; Imano, Hironori; Muraki, Isao; Hayama-Terada, Mina; Shimizu, Yuji; Cui, Renzhe; Kitamura, Akihiko; Kiyama, Masahiko; Okada, Takeo; Ohira, Tetsuya; Yamagishi, Kazumasa; Umesawa, Mitsumasa; Sankai, Tomoko; Iso, Hiroyasu

    2017-01-01

    Objective The prognostic importance of changes in ischaemic ECG abnormalities over time (especially ST-T abnormalities) among Asians has not been fully investigated. We examined the associations between changes in ischaemic abnormalities upon serial ECG (improvement, persistence, deterioration) and cardiovascular disease (CVD) risk. Methods A prospective study cohort was conducted with 9374 men and women aged 40–69 years in four communities. Participants had multiple ECGs at study entry and during the next 10 years, and were followed up for a median period of 23.0 years. Total CVD (stroke and coronary heart disease) was ascertained under systematic surveillance. ECG abnormalities were defined by the Minnesota Code, ST depression (Code4), abnormal T wave (Code5) and categorised into nine groups (no–no, no–minor, no–major, minor–no, minor–minor, minor–major, major–no, major–minor, major–major) by comparison with the point of entrance and maximum change. Results We documented 1196 CVD events. Compared with no–no abnormality, no–minor, minor–major and major–major in Code4, HRs (95% CI) adjusted for cardiovascular risk factors were 1.19 (1.00–1.42), 1.57 (1.15–2.12) and 1.87 (1.42–2.47). Similar results were observed in Code5. Conclusions Changes in ischaemic ECG abnormalities from none to minor, and minor to major, as well as persistent major abnormalities, were associated with an increased risk of CVD. PMID:28176973

  14. Heart-rate variability (HRV) in the ECG trace of routine EEGs: fast monitoring for the anticholinergic effects of clozapine and olanzapine?

    PubMed

    Eschweiler, G W; Bartels, M; Längle, G; Wild, B; Gaertner, I; Nickola, M

    2002-05-01

    Drug monitoring in psychiatry usually serves psychoactive drug plasma concentration measurement. Anticholinergic properties offer a faster approach to monitoring pharmacodynamic intraindividual effects of the drug by measuring their effects on heart rate variability (HRV), which is sympathetically and parasympathetically controlled via cholinergic synapses. The plasma concentrations of the atypical antipsychotics clozapine and olanzapine correlated with parameters of HRV in 59 patients suffering from schizophrenia or schizoaffective disorder. HRV during 4 minutes at rest was extracted from the ECG trace of a routine digital EEG registration in addition to blood sampling for plasma concentration measurement (HPLC method). We calculated sympathetically and parasympathetically controlled heart frequency bands (low, medium and high frequency) and other HRV parameters, coefficient of variation (CV), and root mean square of successive differences (RMSSD). All HRV parameters were significantly more impaired in clozapine patients (n = 33, mean clozapine plasma concentration 331 +/- 294 ng/ml) than in olanzapine patients (n = 26, mean olanzapine plasma concentration 42 +/- 32 ng/ml) and demonstrated 1.7 - 4.8 times the cardiac anticholinergic properties of clozapine in vivo. 14 out of 14 patients with a CV beyond 3.2 % had clozapine plasma concentrations below the proposed optimal therapeutic concentration of 350 ng/ml. All HRV parameters were inversely and significantly correlated with the clozapine plasma concentrations (such as lgCV: r = - 0.73, p < 0.001) and, to a lesser extent, with the olanzapine plasma concentrations (lgCV r = - 0.44, p < 0.05). These results underline the potential clinical value of HRV parameter extraction from routine ECGs in predicting plasma concentrations and objective individual neurocardiac effects of drugs with anticholinergic properties.

  15. 1.5 Tesla MRI-Conditional 12-lead ECG for MR Imaging and Intra-MR Intervention

    PubMed Central

    Tse, Zion Tsz Ho; Dumoulin, Charles L.; Clifford, Gari D.; Schweitzer, Jeff; Qin, Lei; Oster, Julien; Jerosch-Herold, Michael; Kwong, Raymond Y.; Michaud, Gregory; Stevenson, William G.; Schmidt, Ehud J.

    2013-01-01

    Propose High-fidelity 12-lead Electrocardiogram (ECG) is important for physiological monitoring of patients during MR-guided intervention and cardiac MR imaging. Issues in obtaining non-corrupted ECGs inside MRI include a superimposed Magneto-Hydro-Dynamic (MHD) voltage, gradient-switching induced-voltages, and radiofrequency (RF) heating. These problems increase with magnetic field. We intended to develop and clinically validate a 1.5T MRI-conditional 12-lead ECG system. Methods The system was constructed, including transmission-lines to reduce radio-frequency induction, and switching-circuits to remove induced voltages. Adaptive filters, trained by 12-lead measurements outside MRI and in two orientations inside MRI, were used to remove MHD. The system was tested on ten (one exercising) volunteers and four arrhythmia patients. Results Switching circuits removed most imaging-induced voltages (residual noise <3% of the R-wave). MHD removal provided intra-MRI ECGs that varied by <3.8% from those outside the MRI, preserving the true ST segment. In premature-ventricular-contraction (PVC) patients, clean ECGs separated PVC and sinus-rhythm beats. Measured heating was <1.5 C0. The system reliably acquired multiphase (SSFP) wall-motion-cine and phase-contrast-cine scans, including in subjects where 4-lead gating failed. The system required a minimum TR of 4ms to allow robust ECG processing. Conclusion High-fidelity intra-MRI 12-lead ECG is possible. PMID:23580148

  16. Computerized epileptiform transient detection in the scalp electroencephalogram: obstacles to progress and the example of computerized ECG interpretation.

    PubMed

    Halford, Jonathan J

    2009-11-01

    Computerized detection of epileptiform transients (ETs), also called spikes and sharp waves, in the electroencephalogram (EEG) has been a research goal for the last 40years. A reliable method for detecting ETs could improve efficiency in reviewing long EEG recordings and assist physicians in interpreting routine EEGs. Computer algorithms developed so far for detecting ETs are not as reliable as human expert interpreters, mostly due to the large number of false positive detections. Typical methods for ET detection include measuring waveform morphology, detecting signal non-stationarity, and power spectrum analysis. Some progress has been made by using more advanced algorithmic approaches including wavelet analysis, artificial neural networks, and dipole analysis. Comparing the performance of different algorithms is difficult since each study uses its own EEG test dataset. In order to overcome this problem, European researchers in the field of computerized electrocardiogram interpretation organized a large multi-center research workgroup to create a standardized dataset of ECG recordings which were interpreted by a large group of cardiologists. EEG researchers need to follow this as a model and seek funding for the creation of a standardized EEG research dataset to develop ET detection algorithms and certify commercial software.

  17. Pseudoaneurysm of the thoracic aorta sustained during exposure to a tornado diagnosed with ECG-synchronized CT aortography.

    PubMed

    Chakraborty, Amit; von Herrmann, Paul F; Embertson, Ryan E; Landwehr, Kevin P; Winkler, Michael A

    2016-01-01

    A case of a tornado victim with a delayed presentation of injury to the aortic isthmus is discussed. Tornado forces resemble the forces of high energy explosions, and the injuries that can occur as a result of these forces can be bizarre. The patient presented with the unique computed tomography (CT) findings of isolated pseudoaneurysm of the thoracic aorta in the absence of other traumatic injury to the thorax. Equivocal results of the initial CT aortogram (CTA) were confirmed with ECG-synchronized CTA (ECG-CTA), demonstrating the superiority of ECG-CTA as compared to standard CTA.

  18. Erroneous cardiac ECG-gated PET list-mode trigger events can be retrospectively identified and replaced by an offline reprocessing approach: first results in rodents.

    PubMed

    Böning, Guido; Todica, Andrei; Vai, Alessandro; Lehner, Sebastian; Xiong, Guoming; Mille, Erik; Ilhan, Harun; la Fougère, Christian; Bartenstein, Peter; Hacker, Marcus

    2013-11-21

    The assessment of left ventricular function, wall motion and myocardial viability using electrocardiogram (ECG)-gated [(18)F]-FDG positron emission tomography (PET) is widely accepted in human and in preclinical small animal studies. The nonterminal and noninvasive approach permits repeated in vivo evaluations of the same animal, facilitating the assessment of temporal changes in disease or therapy response. Although well established, gated small animal PET studies can contain erroneous gating information, which may yield to blurred images and false estimation of functional parameters. In this work, we present quantitative and visual quality control (QC) methods to evaluate the accuracy of trigger events in PET list-mode and physiological data. Left ventricular functional analysis is performed to quantify the effect of gating errors on the end-systolic and end-diastolic volumes, and on the ejection fraction (EF). We aim to recover the cardiac functional parameters by the application of the commonly established heart rate filter approach using fixed ranges based on a standardized population. In addition, we propose a fully reprocessing approach which retrospectively replaces the gating information of the PET list-mode file with appropriate list-mode decoding and encoding software. The signal of a simultaneously acquired ECG is processed using standard MATLAB vector functions, which can be individually adapted to reliably detect the R-peaks. Finally, the new trigger events are inserted into the PET list-mode file. A population of 30 mice with various health statuses was analyzed and standard cardiac parameters such as mean heart rate (119 ms ± 11.8 ms) and mean heart rate variability (1.7 ms ± 3.4 ms) derived. These standard parameter ranges were taken into account in the QC methods to select a group of nine optimal gated and a group of eight sub-optimal gated [(18)F]-FDG PET scans of mice from our archive. From the list-mode files of the optimal gated group

  19. Erroneous cardiac ECG-gated PET list-mode trigger events can be retrospectively identified and replaced by an offline reprocessing approach: first results in rodents

    NASA Astrophysics Data System (ADS)

    Böning, Guido; Todica, Andrei; Vai, Alessandro; Lehner, Sebastian; Xiong, Guoming; Mille, Erik; Ilhan, Harun; la Fougère, Christian; Bartenstein, Peter; Hacker, Marcus

    2013-11-01

    The assessment of left ventricular function, wall motion and myocardial viability using electrocardiogram (ECG)-gated [18F]-FDG positron emission tomography (PET) is widely accepted in human and in preclinical small animal studies. The nonterminal and noninvasive approach permits repeated in vivo evaluations of the same animal, facilitating the assessment of temporal changes in disease or therapy response. Although well established, gated small animal PET studies can contain erroneous gating information, which may yield to blurred images and false estimation of functional parameters. In this work, we present quantitative and visual quality control (QC) methods to evaluate the accuracy of trigger events in PET list-mode and physiological data. Left ventricular functional analysis is performed to quantify the effect of gating errors on the end-systolic and end-diastolic volumes, and on the ejection fraction (EF). We aim to recover the cardiac functional parameters by the application of the commonly established heart rate filter approach using fixed ranges based on a standardized population. In addition, we propose a fully reprocessing approach which retrospectively replaces the gating information of the PET list-mode file with appropriate list-mode decoding and encoding software. The signal of a simultaneously acquired ECG is processed using standard MATLAB vector functions, which can be individually adapted to reliably detect the R-peaks. Finally, the new trigger events are inserted into the PET list-mode file. A population of 30 mice with various health statuses was analyzed and standard cardiac parameters such as mean heart rate (119 ms ± 11.8 ms) and mean heart rate variability (1.7 ms ± 3.4 ms) derived. These standard parameter ranges were taken into account in the QC methods to select a group of nine optimal gated and a group of eight sub-optimal gated [18F]-FDG PET scans of mice from our archive. From the list-mode files of the optimal gated group, we

  20. On the use of advanced numerical models for the evaluation of dosimetric parameters and the verification of exposure limits at workplaces.

    PubMed

    Catarinucci, L; Tarricone, L

    2009-12-01

    With the next transposition of the 2004/40/EC Directive, employers will become responsible for the electromagnetic field level at the workplace. To make this task easier, the scientific community is compiling practical guidelines to be followed. This work aims at enriching such guidelines, especially for the dosimetric issues. More specifically, some critical aspects related to the application of numerical dosimetric techniques for the verification of the safety limit compliance have been highlighted. In particular, three different aspects have been considered: the dosimetric parameter dependence on the shape and the inner characterisation of the exposed subject as well as on the numerical algorithm used, and the correlation between reference limits and basic restriction. Results and discussions demonstrate how, even by using sophisticated numerical techniques, in some cases a complex interpretation of the result is mandatory.

  1. Technically Extended MultiParameter Optimization (TEMPO): An Advanced Robust Scoring Scheme To Calculate Central Nervous System Druggability and Monitor Lead Optimization.

    PubMed

    Ghose, Arup K; Ott, Gregory R; Hudkins, Robert L

    2017-01-18

    At the discovery stage, it is important to understand the drug design concepts for a CNS drug compared to those for a non-CNS drug. Previously, we published on ideal CNS drug property space and defined in detail the physicochemical property distribution of CNS versus non-CNS oral drugs, the application of radar charting (a graphical representation of multiple physicochemical properties used during CNS lead optimization), and a recursive partition classification tree to differentiate between CNS- and non-CNS drugs. The objective of the present study was to further understand the differentiation of physicochemical properties between CNS and non-CNS oral drugs by the development and application of a new CNS scoring scheme: Technically Extended MultiParameter Optimization (TEMPO). In this multiparameter method, we identified eight key physicochemical properties critical for accurately assessing CNS druggability: (1) number of basic amines, (2) carbon-heteroatom (non-carbon, non-hydrogen) ratio, (3) number of aromatic rings, (4) number of chains, (5) number of rotatable bonds, (6) number of H-acceptors, (7) computed octanol/water partition coefficient (AlogP), and (8) number of nonconjugated C atoms in nonaromatic rings. Significant features of the CNS-TEMPO penalty score are the extension of the multiparameter approach to generate an accurate weight factor for each physicochemical property, the use of limits on both sides of the computed property space range during the penalty calculation, and the classification of CNS and non-CNS drug scores. CNS-TEMPO significantly outperformed CNS-MPO and the Schrödinger QikProp CNS parameter (QP_CNS) in evaluating CNS drugs and has been extensively applied in support of CNS lead optimization programs.

  2. Complementary Bandwidth Extension Method Using Analog Forward and Digital Inverse Filters and Its Application to Noncontact ECG Measurement

    NASA Astrophysics Data System (ADS)

    Kowada, Daisuke; Ueno, Akinori

    In this paper, we propose a novel method for extending bandwidth of ECG measuring device without deteriorating the baseline tolerance for body motion. The proposed method is realized by synthesizing a two-stage analog forward filter with two different corner frequencies and a digital inverse filter having a corner frequency identical with the higher one of the analog filter. We applied the method to bed-type capacitive ECG sensor which can detect electrocardiographic potential non-intrusively and indirectly. The results demonstrated that the proposed method could precisely recover low-frequency components like T-wave. Furthermore, we confirmed that QTc (corrected QT interval) could be estimated from the recovered wave and that the QTc correlated 0.81 on the average with that obtained from Lead II ECG for seven subjects. These results indicate that the proposed method is useful to screening of long QT syndrome by combining the method with the bed-type capacitive ECG sensor.

  3. CardioGuard: A Brassiere-Based Reliable ECG Monitoring Sensor System for Supporting Daily Smartphone Healthcare Applications

    PubMed Central

    Kwon, Sungjun; Kim, Jeehoon; Kang, Seungwoo; Lee, Youngki; Baek, Hyunjae

    2014-01-01

    Abstract We propose CardioGuard, a brassiere-based reliable electrocardiogram (ECG) monitoring sensor system, for supporting daily smartphone healthcare applications. It is designed to satisfy two key requirements for user-unobtrusive daily ECG monitoring: reliability of ECG sensing and usability of the sensor. The system is validated through extensive evaluations. The evaluation results showed that the CardioGuard sensor reliably measure the ECG during 12 representative daily activities including diverse movement levels; 89.53% of QRS peaks were detected on average. The questionnaire-based user study with 15 participants showed that the CardioGuard sensor was comfortable and unobtrusive. Additionally, the signal-to-noise ratio test and the washing durability test were conducted to show the high-quality sensing of the proposed sensor and its physical durability in practical use, respectively. PMID:25405527

  4. An optimized compression algorithm for real-time ECG data transmission in wireless network of medical information systems.

    PubMed

    Cho, Gyoun-Yon; Lee, Seo-Joon; Lee, Tae-Ro

    2015-01-01

    Recent medical information systems are striving towards real-time monitoring models to care patients anytime and anywhere through ECG signals. However, there are several limitations such as data distortion and limited bandwidth in wireless communications. In order to overcome such limitations, this research focuses on compression. Few researches have been made to develop a specialized compression algorithm for ECG data transmission in real-time monitoring wireless network. Not only that, recent researches' algorithm is not appropriate for ECG signals. Therefore this paper presents a more developed algorithm EDLZW for efficient ECG data transmission. Results actually showed that the EDLZW compression ratio was 8.66, which was a performance that was 4 times better than any other recent compression method widely used today.

  5. Fetal ECG Extraction from Abdominal Signals: A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics

    PubMed Central

    Ţarălungă, Dragoş-Daniel; Ungureanu, Georgeta-Mihaela; Gussi, Ilinca; Strungaru, Rodica; Wolf, Werner

    2014-01-01

    Interference of power line (PLI) (fundamental frequency and its harmonics) is usually present in biopotential measurements. Despite all countermeasures, the PLI still corrupts physiological signals, for example, electromyograms (EMG), electroencephalograms (EEG), and electrocardiograms (ECG). When analyzing the fetal ECG (fECG) recorded on the maternal abdomen, the PLI represents a particular strong noise component, being sometimes 10 times greater than the fECG signal, and thus impairing the extraction of any useful information regarding the fetal health state. Many signal processing methods for cancelling the PLI from biopotentials are available in the literature. In this review study, six different principles are analyzed and discussed, and their performance is evaluated on simulated data (three different scenarios), based on five quantitative performance indices. PMID:24660020

  6. VLSI implementation of a new LMS-based algorithm for noise removal in ECG signal

    NASA Astrophysics Data System (ADS)

    Satheeskumaran, S.; Sabrigiriraj, M.

    2016-06-01

    Least mean square (LMS)-based adaptive filters are widely deployed for removing artefacts in electrocardiogram (ECG) due to less number of computations. But they posses high mean square error (MSE) under noisy environment. The transform domain variable step-size LMS algorithm reduces the MSE at the cost of computational complexity. In this paper, a variable step-size delayed LMS adaptive filter is used to remove the artefacts from the ECG signal for improved feature extraction. The dedicated digital Signal processors provide fast processing, but they are not flexible. By using field programmable gate arrays, the pipelined architectures can be used to enhance the system performance. The pipelined architecture can enhance the operation efficiency of the adaptive filter and save the power consumption. This technique provides high signal-to-noise ratio and low MSE with reduced computational complexity; hence, it is a useful method for monitoring patients with heart-related problem.

  7. Semia: semi-automatic interactive graphic editing tool to annotate ambulatory ECG records.

    PubMed

    Dorn, Roman; Jager, Franc

    2004-09-01

    We designed and developed a special purpose interactive graphic editing tool semi-automatic (Semia) to annotate transient ischaemic ST segment episodes and other non-ischaemic ST segment events in 24h ambulatory electrocardiogram (ECG) records. The tool allows representation and viewing of the data, interaction with the data globally and locally at different resolutions, examining data at any point, manual adjustment of heart-beat fiducial points, and manual and automatic editing of annotations. Efficient and fast display of ambulatory ECG signal waveforms, display of diagnostic and morphology feature-vector time-series, dynamic interface controls, and automated procedures to help annotate, made the tool efficient, user friendly and usable. Human expert annotators used the Semia tool to successfully annotate the Long-Term ST database (LTST DB), a result of a multinational effort. The tool supported paperless editing of annotations at dislocated geographical sites. We present design, characteristic "look and feel", functionality, and development of Semia annotating tool.

  8. Improving ECG Classification Accuracy Using an Ensemble of Neural Network Modules

    PubMed Central

    Javadi, Mehrdad; Ebrahimpour, Reza; Sajedin, Atena; Faridi, Soheil; Zakernejad, Shokoufeh

    2011-01-01

    This paper illustrates the use of a combined neural network model based on Stacked Generalization method for classification of electrocardiogram (ECG) beats. In conventional Stacked Generalization method, the combiner learns to map the base classifiers' outputs to the target data. We claim adding the input pattern to the base classifiers' outputs helps the combiner to obtain knowledge about the input space and as the result, performs better on the same task. Experimental results support our claim that the additional knowledge according to the input space, improves the performance of the proposed method which is called Modified Stacked Generalization. In particular, for classification of 14966 ECG beats that were not previously seen during training phase, the Modified Stacked Generalization method reduced the error rate for 12.41% in comparison with the best of ten popular classifier fusion methods including Max, Min, Average, Product, Majority Voting, Borda Count, Decision Templates, Weighted Averaging based on Particle Swarm Optimization and Stacked Generalization. PMID:22046232

  9. Numerical simulation of motion-induced dynamic noise in a ubiquitous ECG application.

    PubMed

    Kim, Young Tae; Lim, Ki Moo; Hong, Seong Bae; Ryu, Ah Jin; Ko, Byung Hoon; Bae, Sang Kon; Shin, Kun Soo; Shim, Eun Bo

    2011-01-01

    Wearable ubiquitous biomedical applications, such as ECG monitors, can generate dynamic noise as a person moves. However, the source of this noise is not clear. We postulated that the dynamic ECG noise has two causes: the change in displacement of the heart during motion and the change in the electrical impedance of the skin-gel interface due to motion-induced deformation of the skin-gel interface. Using a three-dimensional electrophysiological heart model coupled with a torso model, dynamic noise was simulated, while the displacement of the heart was changed in the vertical and horizontal directions, independently and while the skin-gel interface was deformed during motion. To determine the deformation rate of the skin and sol-gel layers, motion-induced deformation of the two layers was simulated using a three-dimensional finite element method.

  10. An ECG recording front-end with continuous-time level-crossing sampling.

    PubMed

    Li, Yongjia; Mansano, Andre L; Yuan, Yuan; Zhao, Duan; Serdijn, Wouter A

    2014-10-01

    An ECG recording front-end with a continuous- time asynchronous level-crossing analog-to-digital converter (LC-ADC) is proposed. The system is a voltage and current mixed-mode system, which comprises a low noise amplifier (LNA), a programmable voltage-to-current converter (PVCC) as a programmable gain amplifier (PGA) and an LC-ADC with calibration DACs and an RC oscillator. The LNA shows an input referred noise of 3.77 μVrms over 0.06 Hz-950 Hz bandwidth. The total harmonic distortion (THD) of the LNA is 0.15% for a 10 mVPP input. The ECG front-end consumes 8.49 μW from a 1 V supply and achieves an ENOB up to 8 bits. The core area of the proposed front-end is 690 ×710 μm2, fabricated in a 0.18 μm CMOS technology.

  11. A level-crossing based QRS-detection algorithm for wearable ECG sensors.

    PubMed

    Ravanshad, Nassim; Rezaee-Dehsorkh, Hamidreza; Lotfi, Reza; Lian, Yong

    2014-01-01

    In this paper, an asynchronous analog-to-information conversion system is introduced for measuring the RR intervals of the electrocardiogram (ECG) signals. The system contains a modified level-crossing analog-to-digital converter and a novel algorithm for detecting the R-peaks from the level-crossing sampled data in a compressed volume of data. Simulated with MIT-BIH Arrhythmia Database, the proposed system delivers an average detection accuracy of 98.3%, a sensitivity of 98.89%, and a positive prediction of 99.4%. Synthesized in 0.13 μm CMOS technology with a 1.2 V supply voltage, the overall system consumes 622 nW with core area of 0.136 mm (2), which make it suitable for wearable wireless ECG sensors in body-sensor networks.

  12. Toward Improving Electrocardiogram (ECG) Biometric Verification using Mobile Sensors: A Two-Stage Classifier Approach.

    PubMed

    Tan, Robin; Perkowski, Marek

    2017-02-20

    Electrocardiogram (ECG) signals sensed from mobile devices pertain the potential for biometric identity recognition applicable in remote access control systems where enhanced data security is demanding. In this study, we propose a new algorithm that consists of a two-stage classifier combining random forest and wavelet distance measure through a probabilistic threshold schema, to improve the effectiveness and robustness of a biometric recognition system using ECG data acquired from a biosensor integrated into mobile devices. The proposed algorithm is evaluated using a mixed dataset from 184 subjects under different health conditions. The proposed two-stage classifier achieves a total of 99.52% subject verification accuracy, better than the 98.33% accuracy from random forest alone and 96.31% accuracy from wavelet distance measure algorithm alone. These results demonstrate the superiority of the proposed algorithm for biometric identification, hence supporting its practicality in areas such as cloud data security, cyber-security or remote healthcare systems.

  13. Custom FPGA processing for real-time fetal ECG extraction and identification.

    PubMed

    Torti, E; Koliopoulos, D; Matraxia, M; Danese, G; Leporati, F

    2017-01-01

    Monitoring the fetal cardiac activity during pregnancy is of crucial importance for evaluating fetus health. However, there is a lack of automatic and reliable methods for Fetal ECG (FECG) monitoring that can perform this elaboration in real-time. In this paper, we present a hardware architecture, implemented on the Altera Stratix V FPGA, capable of separating the FECG from the maternal ECG and to correctly identify it. We evaluated our system using both synthetic and real tracks acquired from patients beyond the 20th pregnancy week. This work is part of a project aiming at developing a portable system for FECG continuous real-time monitoring. Its characteristics of reduced power consumption, real-time processing capability and reduced size make it suitable to be embedded in the overall system, that is the first proposed exploiting Blind Source Separation with this technology, to the best of our knowledge.

  14. Implementation of a Data Packet Generator Using Pattern Matching for Wearable ECG Monitoring Systems

    PubMed Central

    Noh, Yun Hong; Jeong, Do Un

    2014-01-01

    In this paper, a packet generator using a pattern matching algorithm for real-time abnormal heartbeat detection is proposed. The packet generator creates a very small data packet which conveys sufficient crucial information for health condition analysis. The data packet envelopes real time ECG signals and transmits them to a smartphone via Bluetooth. An Android application was developed specifically to decode the packet and extract ECG information for health condition analysis. Several graphical presentations are displayed and shown on the smartphone. We evaluate the performance of abnormal heartbeat detection accuracy using the MIT/BIH Arrhythmia Database and real time experiments. The experimental result confirm our finding that abnormal heart beat detection is practically possible. We also performed data compression ratio and signal restoration performance evaluations to establish the usefulness of the proposed packet generator and the results were excellent. PMID:25029280

  15. A real-time ECG data compression algorithm for a digital holter system.

    PubMed

    Lee, Sangjoon; Lee, Myoungho

    2008-01-01

    This paper describes a real time ECG compression algorithm for a digital holter system. Proposed algorithm consists of five main procedures. First procedure is to differentiate signals, second is to choose a period of the differentiated signals and store them in memory, third is to perform the DCT(Discrete Cosine Transform) on the stored data, fourth is to apply a window filter, and fifth procedure is to apply Huffman Coding compression method on the data. This developed algorithm has been tested by applying 12 ECGs(electrocardiograms) from the MIT-BIH database and the PRD(Percent RMS Difference) and the CR(Compression Ratio) are calculated. It is found that the algorithm achieved a high level of compression performance with 1.82 of PRD and 8.82:1 of CR in average.

  16. Toward Improving Electrocardiogram (ECG) Biometric Verification using Mobile Sensors: A Two-Stage Classifier Approach

    PubMed Central

    Tan, Robin; Perkowski, Marek

    2017-01-01

    Electrocardiogram (ECG) signals sensed from mobile devices pertain the potential for biometric identity recognition applicable in remote access control systems where enhanced data security is demanding. In this study, we propose a new algorithm that consists of a two-stage classifier combining random forest and wavelet distance measure through a probabilistic threshold schema, to improve the effectiveness and robustness of a biometric recognition system using ECG data acquired from a biosensor integrated into mobile devices. The proposed algorithm is evaluated using a mixed dataset from 184 subjects under different health conditions. The proposed two-stage classifier achieves a total of 99.52% subject verification accuracy, better than the 98.33% accuracy from random forest alone and 96.31% accuracy from wavelet distance measure algorithm alone. These results demonstrate the superiority of the proposed algorithm for biometric identification, hence supporting its practicality in areas such as cloud data security, cyber-security or remote healthcare systems. PMID:28230745

  17. [A rapid fetal ECG acquisition system based on FT245RL].

    PubMed

    Fu, Binggen; Yang, Zuyuan; Cai, Kun; Xie, Shengli

    2014-11-01

    A rapid fetal ECG signal acquisition system is designed, which includes three modules: a front-end signal acquisition module, a micro control module and a PC software application module. The first two modules are accomplished through the ADS1294 and the STM32F103 chips, respectively, and the third one is developed in VC++ platform. By using the FT245RL chip, the proposed system implements the serial-parallel conversion communication between ARM and PC, improving the data transmission rate largely. Also, it has a simple structure, with low power consumption and high precision. Furthermore, it can collect fetal ECG signals from mother's abdominal wall and convert them into the 24-bit digital signals.

  18. Solving the ECG forward problem by means of a meshless finite element method.

    PubMed

    Li, Z S; Zhu, S A; He, Bin

    2007-07-07

    The conventional numerical computational techniques such as the finite element method (FEM) and the boundary element method (BEM) require laborious and time-consuming model meshing. The new meshless FEM only uses the boundary description and the node distribution and no meshing of the model is required. This paper presents the fundamentals and implementation of meshless FEM and the meshless FEM method is adapted to solve the electrocardiography (ECG) forward problem. The method is evaluated on a single-layer torso model, in which the analytical solution exists, and tested in a realistic geometry homogeneous torso model, with satisfactory results being obtained. The present results suggest that the meshless FEM may provide an alternative for ECG forward solutions.

  19. Clinical applications of T-wave alternans assessed during exercise stress testing and ambulatory ECG monitoring.

    PubMed

    Verrier, Richard L; Malik, Marek

    2013-01-01

    Analytical methods to measure T-wave alternans (TWA), a beat-to-beat fluctuation in the morphology of the ST-segment and T wave in the electrocardiogram (ECG), have been developed to address the unmet challenge of identifying individuals at increased risk for sudden cardiac death. Conventional noninvasive markers including left ventricular ejection fraction have significant limitations as many individuals who die suddenly have relatively preserved ventricular mechanical function. TWA is an attractive marker as it is closely linked to ECG heterogeneity and abnormalities in calcium handling, key factors in arrhythmogenesis. The objectives of this review are to summarize the clinical evidence supporting use of TWA in risk stratification and to discuss its current and potential applications in guiding device and medical therapy.

  20. Sleep stage classification with ECG and respiratory effort.

    PubMed

    Fonseca, Pedro; Long, Xi; Radha, Mustafa; Haakma, Reinder; Aarts, Ronald M; Rolink, Jérôme

    2015-10-01

    Automatic sleep stage classification with cardiorespiratory signals has attracted increasing attention. In contrast to the traditional manual scoring based on polysomnography, these signals can be measured using advanced unobtrusive techniques that are currently available, promising the application for personal and continuous home sleep monitoring. This paper describes a methodology for classifying wake, rapid-eye-movement (REM) sleep, and non-REM (NREM) light and deep sleep on a 30 s epoch basis. A total of 142 features were extracted from electrocardiogram and thoracic respiratory effort measured with respiratory inductance plethysmography. To improve the quality of these features, subject-specific Z-score normalization and spline smoothing were used to reduce between-subject and within-subject variability. A modified sequential forward selection feature selector procedure was applied, yielding 80 features while preventing the introduction of bias in the estimation of cross-validation performance. PSG data from 48 healthy adults were used to validate our methods. Using a linear discriminant classifier and a ten-fold cross-validation, we achieved a Cohen's kappa coefficient of 0.49 and an accuracy of 69% in the classification of wake, REM, light, and deep sleep. These values increased to kappa = 0.56 and accuracy = 80% when the classification problem was reduced to three classes, wake, REM sleep, and NREM sleep.

  1. A comparison of sea ice parameters computed from Advanced Very High Resolution Radiometer and Landsat satellite imagery and from airborne passive microwave radiometry

    NASA Technical Reports Server (NTRS)

    Emery, W. J.; Radebaugh, M.; Fowler, C. W.; Cavalieri, D.; Steffen, K.

    1991-01-01

    AVHRR-derived sea ice parameters from the Bering Sea are compared with those computed from nearly coincident (within 6 hr) Landsat MSS imagery and from the Aircraft Multichannel Microwave Radiometer (AMMR) flown on the NASA DC-8 in order to evaluate the accuracy and reliability of AVHRR-mapped sea-ice concentration and ice edge. Mean ice-concentration differences between AVHRR near-infrared (channel 2) and Landsat MSS data ranged from -0.8 to 1.8 percent with a mean value of 0.5 percent; rms differences ranged from 6.8 to 17.7 percent. Mean differences were larger for AVHRR thermal infrared (channel 4) ice concentrations ranging from -2.2 to 8.4 percent with rms differences from 8.6 to 26.8 percent. Mean differences between AVHRR channel 2 concentrations and the AMMR data ranged from -19.7 to 18.9 percent, while rms values went from 17.0 to 44.8 percent.

  2. Report on the recent advances performed in the determination of radiative parameters for spectral lines of astrophysical interest in heavy elements

    NASA Astrophysics Data System (ADS)

    Quinet, Pascal

    2015-08-01

    Heavy atoms and ions of the periodic table, in particular those with Z > 36, have been rather little investigated up to until very recently, due to the numerous difficulties met both on the theoretical and on the experimental sides. In relation with the recent needs in astrophysics, the situtaion has considerably evolved over the past few years and substantial progress has been reported. This progress has been made easier by the developments of theoretical methods and also by the extensive use of laser spectroscopy.Having in mind the astrophysical context, we have started a systematic investigation of radiative parameters of these ions (neutral, singly and doubly ionized elements) about 15 years ago. As a consequence, a large number of new results have been obtained. About 700 radiative lifetimes have been measured by time-resolved laser-induced fluorescence spectroscopy. The combination of these lifetimes with theoretical (and, when possible, experimental) branching fractions has led to transition probabilities for about 100000 transitions in atoms and ions belonging to the lanthanide group as well as to the fifth and the sixth rows of the periodic table.

  3. Fitting psychometric functions using a fixed-slope parameter: an advanced alternative for estimating odor thresholds with data generated by ASTM E679.

    PubMed

    Peng, Mei; Jaeger, Sara R; Hautus, Michael J

    2014-03-01

    Psychometric functions are predominately used for estimating detection thresholds in vision and audition. However, the requirement of large data quantities for fitting psychometric functions (>30 replications) reduces their suitability in olfactory studies because olfactory response data are often limited (<4 replications) due to the susceptibility of human olfactory receptors to fatigue and adaptation. This article introduces a new method for fitting individual-judge psychometric functions to olfactory data obtained using the current standard protocol-American Society for Testing and Materials (ASTM) E679. The slope parameter of the individual-judge psychometric function is fixed to be the same as that of the group function; the same-shaped symmetrical sigmoid function is fitted only using the intercept. This study evaluated the proposed method by comparing it with 2 available methods. Comparison to conventional psychometric functions (fitted slope and intercept) indicated that the assumption of a fixed slope did not compromise precision of the threshold estimates. No systematic difference was obtained between the proposed method and the ASTM method in terms of group threshold estimates or threshold distributions, but there were changes in the rank, by threshold, of judges in the group. Overall, the fixed-slope psychometric function is recommended for obtaining relatively reliable individual threshold estimates when the quantity of data is limited.

  4. Motion artifacts in capacitive ECG measurements: reducing the combined effect of DC voltages and capacitance changes using an injection signal.

    PubMed

    Serteyn, A; Vullings, R; Meftah, M; Bergmans, J W M

    2015-01-01

    Capacitive electrodes are a promising alternative to the conventional adhesive electrodes for ECG measurements. They provide more comfort to the patient when integrated in everyday objects (e.g., beds or seats) for long-term monitoring. However, the application of capacitive sensors is limited by their high sensitivity to motion artifacts. For example, motion at the body-electrode interface causes variations of the coupling capacitance which, in the presence of a dc voltage across the coupling capacitor, create strong artifacts in the measurements. The origin, relevance, and reduction of this specific and important type of artifacts are studied here. An injection signal is exploited to track the variations of the coupling capacitance in real time. This information is then used by an identification scheme to estimate the artifacts and subtract them from the measurements. The method was evaluated in simulations, lab environments, and in a real-life recording on an adult's chest. For the type of artifact under study, a strong artifact reduction ranging from 40 dB for simulated data to 9 dB for a given real-life recording was achieved. The proposed method is automated, does not require any knowledge about the measurement system parameters, and provides an online estimate for the dc voltage across the coupling capacitor.

  5. Transmitting SPIHT Compressed ECG Data Over a Next-Generation Mobile Telecardiology Testbed

    DTIC Science & Technology

    2007-11-02

    formance of the testbed for the compressed ECG data segments selected from the MIT-BIH arrhythmia database is evaluated in ter ms of BER (bit er ror...the MIT/BIH arrhythmia database are transmitted. Finally, a conclusion is given in Section IV. II. NEXT-GENERATION MOBILE TELECARDIOLOGY TESTBED A... source is compressed by the SPIHT, the resultant bits are encoded frame-by-frame and the frame length is 10ms. First, it is attached by CRC (Cyclic

  6. Synthesize, optimize, analyze, repeat (SOAR): Application of neural network tools to ECG patient monitoring

    SciTech Connect

    Watrous, R.; Towell, G.; Glassman, M.S.

    1995-12-31

    Results are reported from the application of tools for synthesizing, optimizing and analyzing neural networks to an ECG Patient Monitoring task. A neural network was synthesized from a rule-based classifier and optimized over a set of normal and abnormal heartbeats. The classification error rate on a separate and larger test set was reduced by a factor of 2. When the network was analyzed and reduced in size by a factor of 40%, the same level of performance was maintained.

  7. Biomedical Implementation of Liquid Metal Ink as Drawable ECG Electrode and Skin Circuit

    PubMed Central

    Yu, Yang; Zhang, Jie; Liu, Jing

    2013-01-01

    Background Conventional ways of making bio-electrodes are generally complicated, expensive and unconformable. Here we describe for the first time the method of applying Ga-based liquid metal ink as drawable electrocardiogram (ECG) electrodes. Such material owns unique merits in both liquid phase conformability and high electrical conductivity, which provides flexible ways for making electrical circuits on skin surface and a prospective substitution of conventional rigid printed circuit boards (PCBs). Methods Fundamental measurements of impedance and polarization voltage of the liquid metal ink were carried out to evaluate its basic electrical properties. Conceptual experiments were performed to draw the alloy as bio-electrodes to acquire ECG signals from both rabbit and human via a wireless module developed on the mobile phone. Further, a typical electrical circuit was drawn in the palm with the ink to demonstrate its potential of implementing more sophisticated skin circuits. Results With an oxide concentration of 0.34%, the resistivity of the liquid metal ink was measured as 44.1 µΩ·cm with quite low reactance in the form of straight line. Its peak polarization voltage with the physiological saline was detected as −0.73 V. The quality of ECG wave detected from the liquid metal electrodes was found as good as that of conventional electrodes, from both rabbit and human experiments. In addition, the circuit drawn with the liquid metal ink in the palm also runs efficiently. When the loop was switched on, all the light emitting diodes (LEDs) were lit and emitted colorful lights. Conclusions The liquid metal ink promises unique printable electrical properties as both bio-electrodes and electrical wires. The implemented ECG measurement on biological surface and the successfully run skin circuit demonstrated the conformability and attachment of the liquid metal. The present method is expected to innovate future physiological measurement and biological circuit

  8. How can computerized interpretation algorithms adapt to gender/age differences in ECG measurements?

    PubMed

    Xue, Joel; Farrell, Robert M

    2014-01-01

    It is well known that there are gender differences in 12 lead ECG measurements, some of which can be statistically significant. It is also an accepted practice that we should consider those differences when we interpret ECGs, by either a human overreader or a computerized algorithm. There are some major gender differences in 12 lead ECG measurements based on automatic algorithms, including global measurements such as heart rate, QRS duration, QT interval, and lead-by-lead measurements like QRS amplitude, ST level, etc. The interpretation criteria used in the automatic algorithms can be adapted to the gender differences in the measurements. The analysis of a group of 1339 patients with acute inferior MI showed that for patients under age 60, women had lower ST elevations at the J point in lead II than men (57±91μV vs. 86±117μV, p<0.02). This trend was reversed for patients over age 60 (lead aVF: 102±126μV vs. 84±117μV, p<0.04; lead III: 130±146μV vs. 103±131μV, p<0.007). Therefore, the ST elevation thresholds were set based on available gender and age information, which resulted in 25% relative sensitivity improvement for women under age 60, while maintaining a high specificity of 98%. Similar analyses were done for prolonged QT interval and LVH cases. The paper uses several design examples to demonstrate (1) how to design a gender-specific algorithm, and (2) how to design a robust ECG interpretation algorithm which relies less on absolute threshold-based criteria and is instead more reliant on overall morphology features, which are especially important when gender information is unavailable for automatic analysis.

  9. A new method for QRS complex detection in multichannel ECG: Application to self-monitoring of fetal health.

    PubMed

    Varanini, Maurizio; Tartarisco, Gennaro; Balocchi, Rita; Macerata, Alberto; Pioggia, Giovanni; Billeci, Lucia

    2016-04-13

    This paper proposes a new approach for QRS complex detection in multichannel ECG and presents its application to fetal QRS (fQRS) detection in signals acquired from maternal abdominal leads. The method exploits the characteristics of pseudo-periodicity and time shape of QRS, it consists of devising a quality index (QI) which synthesizes these characteristics and of finding the linear combination of the acquired ECGs, which maximizes this QI. In the application for fQRS detection two QIs are devised, one QI (mQI) for maternal ECG (mECG) and one QI (fQI) for fetal ECG (fECG). The method is completely unsupervised and based on the following steps: signal pre-processing; maternal QRS-enhanced signal extraction by finding the linear combination that maximize the mQI; detection of maternal QRSs; mECG component approximation and canceling by weighted Singular Value Decomposition (SVD); fQRS-enhanced signal extraction by finding the linear combination that maximize the fQI and fQRS detection. The proposed method was compared with our previously developed Independent Component Analysis (ICA) based method as well as with simple mECG canceling and simple ICA methods. The comparison was carried out by evaluating the performances of the procedures in fQRS detection. The new method outperformed the results of the other approaches on the annotated open set of the Computing in Cardiology Challenge 2013 database. The proposed method seems to be promising for its implementation on portable device and for use in self-monitoring of fetal health in pregnant women.

  10. Multiresolution wavelet analysis of the body surface ECG before and after angioplasty.

    PubMed

    Gramatikov, B; Yi-Chun, S; Rix, H; Caminal, P; Thakor, N V

    1995-01-01

    Electrocardiographic recordings of patients with coronary artery stenosis, made before and after angioplasty, were analyzed by the multiresolution wavelet transform (MRWT) technique. The MRWT decomposes the signal of interest into its coarse and detail components at successively finer scales. MRWT was carried out on different leads in order to compare the P-QRS-T complex from recordings made before with those made after percutaneous transluminal coronary angioplasty (PTCA). ECG signals before and after successful PTCA procedures show distinctive changes at certain scales, thus helping to identify whether the procedure has been successful. In six patients who underwent right coronary artery PTCA, varying levels of reperfusion were achieved, and the changes in the detail components of ECG were shown to correlate with the successful reperfusion. The detail components at scales 5 and 6, corresponding approximately to the frequencies in the range of 2.3-8.3 Hz, are shown to be the most sensitive to ischemia-reperfusion changes (p < 0.05). The same conclusion was reached by synthesizing the post-PTCA signals from pre-PTCA signals with the help of these detail components. For on-line monitoring a vector plot, analogous to vector cardiogram, of the two most sensitive MRWT detail components is proposed. Thus, multiresolution analysis of ECG may be useful as a monitoring and diagnostic tool during angioplasty procedures.

  11. An efficient coding algorithm for the compression of ECG signals using the wavelet transform.

    PubMed

    Rajoub, Bashar A

    2002-04-01

    A wavelet-based electrocardiogram (ECG) data compression algorithm is proposed in this paper. The ECG signal is first preprocessed, the discrete wavelet transform (DWT) is then applied to the preprocessed signal. Preprocessing guarantees that the magnitudes of the wavelet coefficients be less than one, and reduces the reconstruction errors near both ends of the compressed signal. The DWT coefficients are divided into three groups, each group is thresholded using a threshold based on a desired energy packing efficiency. A binary significance map is then generated by scanning the wavelet decomposition coefficients and outputting a binary one if the scanned coefficient is significant, and a binary zero if it is insignificant. Compression is achieved by 1) using a variable length code based on run length encoding to compress the significance map and 2) using direct binary representation for representing the significant coefficients. The ability of the coding algorithm to compress ECG signals is investigated, the results were obtained by compressing and decompressing the test signals. The proposed algorithm is compared with direct-based and wavelet-based compression algorithms and showed superior performance. A compression ratio of 24:1 was achieved for MIT-BIH record 117 with a percent root mean square difference as low as 1.08%.

  12. Design, fabrication and skin-electrode contact analysis of polymer microneedle-based ECG electrodes

    NASA Astrophysics Data System (ADS)

    O'Mahony, Conor; Grygoryev, Konstantin; Ciarlone, Antonio; Giannoni, Giuseppe; Kenthao, Anan; Galvin, Paul

    2016-08-01

    Microneedle-based ‘dry’ electrodes have immense potential for use in diagnostic procedures such as electrocardiography (ECG) analysis, as they eliminate several of the drawbacks associated with the conventional ‘wet’ electrodes currently used for physiological signal recording. To be commercially successful in such a competitive market, it is essential that dry electrodes are manufacturable in high volumes and at low cost. In addition, the topographical nature of these emerging devices means that electrode performance is likely to be highly dependent on the quality of the skin-electrode contact. This paper presents a low-cost, wafer-level micromoulding technology for the fabrication of polymeric ECG electrodes that use microneedle structures to make a direct electrical contact to the body. The double-sided moulding process can be used to eliminate post-process via creation and wafer dicing steps. In addition, measurement techniques have been developed to characterize the skin-electrode contact force. We perform the first analysis of signal-to-noise ratio dependency on contact force, and show that although microneedle-based electrodes can outperform conventional gel electrodes, the quality of ECG recordings is significantly dependent on temporal and mechanical aspects of the skin-electrode interface.

  13. A robust and simple security extension for the medical standard SCP-ECG.

    PubMed

    Rubio, Oscar J; Alesanco, Alvaro; García, José

    2013-02-01

    This paper proposes a SCP-ECG security extension after having analyzed the features of this standard, its security requirements and the current measures implemented by other medical protocols. Our approach permits SCP-ECG files to be stored safely and proper access to be granted (or denied) to users for different purposes: interpretation of the test, consultation, clinical research or teaching. The access privileges are scaled by means of role-based profiles supported by cryptographic elements (ciphering, digital certificates and digital signatures). These elements are arranged as metadata into a new section which extends the protocol and protects the remaining sections. The application built to implement this approach has been extensively tested, showing its capacity to authenticate users and to protect the integrity of files and the privacy of sensitive data, with a low impact on file size and access time. In addition, this solution is compatible with any version of the SCP-ECG and can be easily integrated into e-health platforms.

  14. A New Strategy for ECG Baseline Wander Elimination Using Empirical Mode Decomposition

    NASA Astrophysics Data System (ADS)

    Shahbakhti, Mohammad; Bagheri, Hamed; Shekarchi, Babak; Mohammadi, Somayeh; Naji, Mohsen

    2016-06-01

    Electrocardiogram (ECG) signals might be affected by various artifacts and noises that have biological and external sources. Baseline wander (BW) is a low-frequency artifact that may be caused by breathing, body movements and loose sensor contact. In this paper, a novel method based on empirical mode decomposition (EMD) for removal of baseline noise from ECG is presented. When compared to other EMD-based methods, the novelty of this research is to reach the optimized number of decomposed levels for ECG BW de-noising using mean power frequency (MPF), while the reduction of processing time is considered. To evaluate the performance of the proposed method, a fifth-order Butterworth high pass filtering (BHPF) with cut-off frequency at 0.5Hz and wavelet approach are applied. Three performance indices, signal-to-noise ratio (SNR), mean square error (MSE) and correlation coefficient (CC), between pure and filtered signals have been utilized for qualification of presented techniques. Results suggest that the EMD-based method outperforms the other filtering method.

  15. Adaptive motion artefact reduction in respiration and ECG signals for wearable healthcare monitoring systems.

    PubMed

    Zhang, Zhengbo; Silva, Ikaro; Wu, Dalei; Zheng, Jiewen; Wu, Hao; Wang, Weidong

    2014-12-01

    Wearable healthcare monitoring systems (WHMSs) have received significant interest from both academia and industry with the advantage of non-intrusive and ambulatory monitoring. The aim of this paper is to investigate the use of an adaptive filter to reduce motion artefact (MA) in physiological signals acquired by WHMSs. In our study, a WHMS is used to acquire ECG, respiration and triaxial accelerometer (ACC) signals during incremental treadmill and cycle ergometry exercises. With these signals, performances of adaptive MA cancellation are evaluated in both respiration and ECG signals. To achieve effective and robust MA cancellation, three axial outputs of the ACC are employed to estimate the MA by a bank of gradient adaptive Laguerre lattice (GALL) filter, and the outputs of the GALL filters are further combined with time-varying weights determined by a Kalman filter. The results show that for the respiratory signals, MA component can be reduced and signal quality can be improved effectively (the power ratio between the MA-corrupted respiratory signal and the adaptive filtered signal was 1.31 in running condition, and the corresponding signal quality was improved from 0.77 to 0.96). Combination of the GALL and Kalman filters can achieve robust MA cancellation without supervised selection of the reference axis from the ACC. For ECG, the MA component can also be reduced by adaptive filtering. The signal quality, however, could not be improved substantially just by the adaptive filter with the ACC outputs as the reference signals.

  16. Mobile cloud-computing-based healthcare service by noncontact ECG monitoring.

    PubMed

    Fong, Ee-May; Chung, Wan-Young

    2013-12-02

    Noncontact electrocardiogram (ECG) measurement technique has gained popularity these days owing to its noninvasive features and convenience in daily life use. This paper presents mobile cloud computing for a healthcare system where a noncontact ECG measurement method is employed to capture biomedical signals from users. Healthcare service is provided to continuously collect biomedical signals from multiple locations. To observe and analyze the ECG signals in real time, a mobile device is used as a mobile monitoring terminal. In addition, a personalized healthcare assistant is installed on the mobile device; several healthcare features such as health status summaries, medication QR code scanning, and reminders are integrated into the mobile application. Health data are being synchronized into the healthcare cloud computing service (Web server system and Web server dataset) to ensure a seamless healthcare monitoring system and anytime and anywhere coverage of network connection is available. Together with a Web page application, medical data are easily accessed by medical professionals or family members. Web page performance evaluation was conducted to ensure minimal Web server latency. The system demonstrates better availability of off-site and up-to-the-minute patient data, which can help detect health problems early and keep elderly patients out of the emergency room, thus providing a better and more comprehensive healthcare cloud computing service.

  17. Graphite Based Electrode for ECG Monitoring: Evaluation under Freshwater and Saltwater Conditions

    PubMed Central

    Thap, Tharoeun; Yoon, Kwon-Ha; Lee, Jinseok

    2016-01-01

    We proposed new electrodes that are applicable for electrocardiogram (ECG) monitoring under freshwater- and saltwater-immersion conditions. Our proposed electrodes are made of graphite pencil lead (GPL), a general-purpose writing pencil. We have fabricated two types of electrode: a pencil lead solid type (PLS) electrode and a pencil lead powder type (PLP) electrode. In order to assess the qualities of the PLS and PLP electrodes, we compared their performance with that of a commercial Ag/AgCl electrode, under a total of seven different conditions: dry, freshwater immersion with/without movement, post-freshwater wet condition, saltwater immersion with/without movement, and post-saltwater wet condition. In both dry and post-freshwater wet conditions, all ECG-recorded PQRST waves were clearly discernible, with all types of electrodes, Ag/AgCl, PLS, and PLP. On the other hand, under the freshwater- and saltwater-immersion conditions with/without movement, as well as post-saltwater wet conditions, we found that the proposed PLS and PLP electrodes provided better ECG waveform quality, with significant statistical differences compared with the quality provided by Ag/AgCl electrodes. PMID:27092502

  18. Cost-effectiveness of pre-participation screening of athletes with ECG in Europe and Algeria.

    PubMed

    Assanelli, Deodato; Levaggi, Rosella; Carré, François; Sharma, Sanjay; Deligiannis, Asterios; Mellwig, Klaus Peter; Tahmi, Mohamed; Vinetti, Giovanni; Aliverti, Paola

    2015-03-01

    The aim of this study is to evaluate the cost-effectiveness of ECG in combination with family and personal history and physical examination in order to detect cardiovascular diseases that might cause sudden death in athletes. The study was conducted on a cohort of 6,634, mainly young professional and recreational athletes, 1,071 from Algeria and 5,563 from Europe (France, Germany and Greece). Each athlete underwent medical history, physical examination, and resting 12-lead ECG. 293 athletes (4.4 %), 149 in Europe (2.7 %) and 144 in Algeria (13.4 %) required further tests, and 56 were diagnosed with cardiovascular disease and thus disqualified. The cost-effectiveness ratio (CER) was calculated as the ratio between the cost of screening and the number of statistical life-years saved by the intervention. The estimated reduced risk of death deriving from treatment or disqualification resulted in the saving of 79.1 statistical life-years in Europe and 136.3 in Algeria. CER of screening was 4,071 purchasing-power-parity-adjusted US dollars ($PPP) in Europe and 582 $PPP in Algeria. The results of this study strongly support the utilisation of 12-lead ECG in the pre-participation screening of young athletes, especially in countries where secondary preventive care is not highly developed.

  19. Concept Design for a 1-Lead Wearable/Implantable ECG Front-End: Power Management

    PubMed Central

    George, Libin; Gargiulo, Gaetano Dario; Lehmann, Torsten; Hamilton, Tara Julia

    2015-01-01

    Power supply quality and stability are critical for wearable and implantable biomedical applications. For this reason we have designed a reconfigurable switched-capacitor DC-DC converter that, aside from having an extremely small footprint (with an active on-chip area of only 0.04 mm2), uses a novel output voltage control method based upon a combination of adaptive gain and discrete frequency scaling control schemes. This novel DC-DC converter achieves a measured output voltage range of 1.0 to 2.2 V with power delivery up to 7.5 mW with 75% efficiency. In this paper, we present the use of this converter as a power supply for a concept design of a wearable (15 mm × 15 mm) 1-lead ECG front-end sensor device that simultaneously harvests power and communicates with external receivers when exposed to a suitable RF field. Due to voltage range limitations of the fabrication process of the current prototype chip, we focus our analysis solely on the power supply of the ECG front-end whose design is also detailed in this paper. Measurement results show not just that the power supplied is regulated, clean and does not infringe upon the ECG bandwidth, but that there is negligible difference between signals acquired using standard linear power-supplies and when the power is regulated by our power management chip. PMID:26610497

  20. Concept Design for a 1-Lead Wearable/Implantable ECG Front-End: Power Management.

    PubMed

    George, Libin; Gargiulo, Gaetano Dario; Lehmann, Torsten; Hamilton, Tara Julia

    2015-11-19

    Power supply quality and stability are critical for wearable and implantable biomedical applications. For this reason we have designed a reconfigurable switched-capacitor DC-DC converter that, aside from having an extremely small footprint (with an active on-chip area of only 0.04 mm²), uses a novel output voltage control method based upon a combination of adaptive gain and discrete frequency scaling control schemes. This novel DC-DC converter achieves a measured output voltage range of 1.0 to 2.2 V with power delivery up to 7.5 mW with 75% efficiency. In this paper, we present the use of this converter as a power supply for a concept design of a wearable (15 mm × 15 mm) 1-lead ECG front-end sensor device that simultaneously harvests power and communicates with external receivers when exposed to a suitable RF field. Due to voltage range limitations of the fabrication process of the current prototype chip, we focus our analysis solely on the power supply of the ECG front-end whose design is also detailed in this paper. Measurement results show not just that the power supplied is regulated, clean and does not infringe upon the ECG bandwidth, but that there is negligible difference between signals acquired using standard linear power-supplies and when the power is regulated by our power management chip.

  1. Cardiac Autonomic Alteration and Metabolic Syndrome: An Ambulatory ECG-based Study in A General Population

    PubMed Central

    Ma, Yan; Tseng, Ping-Huei; Ahn, Andrew; Wu, Ming-Shiang; Ho, Yi-Lwun; Chen, Ming-Fong; Peng, Chung-Kang

    2017-01-01

    Metabolic syndrome (MetS) has been associated with chronic damage to the cardiovascular system. This study aimed to evaluate early stage cardiac autonomic dysfunction with electrocardiography (ECG)-based measures in MetS subjects. During 2012–2013, 175 subjects with MetS and 226 healthy controls underwent ECG recordings of at least 4 hours starting in the morning with ambulatory one-lead ECG monitors. MetS was diagnosed using the criteria defined in the Adult Treatment Panel III, with a modification of waist circumference for Asians. Conventional heart rate variability (HRV) analysis, and complexity index (CI1–20) calculated from 20 scales of entropy (multiscale entropy, MSE), were compared between subjects with MetS and controls. Compared with the healthy controls, subjects with MetS had significantly reduced HRV, including SDNN and pNN20 in time domain, VLF, LF and HF in frequency domain, as well as SD2 in Poincaré analysis. MetS subjects have significantly lower complexity index (CI1–20) than healthy subjects (1.69 ± 0.18 vs. 1.77 ± 0.12, p < 0.001). MetS severity was inversely associated with the CI1–20 (r = −0.27, p < 0.001). MetS is associated with significant alterations in heart rate dynamics, including HRV and complexity. PMID:28290487

  2. Design of Secure ECG-Based Biometric Authentication in Body Area Sensor Networks

    PubMed Central

    Peter, Steffen; Pratap Reddy, Bhanu; Momtaz, Farshad; Givargis, Tony

    2016-01-01

    Body area sensor networks (BANs) utilize wireless communicating sensor nodes attached to a human body for convenience, safety, and health applications. Physiological characteristics of the body, such as the heart rate or Electrocardiogram (ECG) signals, are promising means to simplify the setup process and to improve security of BANs. This paper describes the design and implementation steps required to realize an ECG-based authentication protocol to identify sensor nodes attached to the same human body. Therefore, the first part of the paper addresses the design of a body-area sensor system, including the hardware setup, analogue and digital signal processing, and required ECG feature detection techniques. A model-based design flow is applied, and strengths and limitations of each design step are discussed. Real-world measured data originating from the implemented sensor system are then used to set up and parametrize a novel physiological authentication protocol for BANs. The authentication protocol utilizes statistical properties of expected and detected deviations to limit the number of false positive and false negative authentication attempts. The result of the described holistic design effort is the first practical implementation of biometric authentication in BANs that reflects timing and data uncertainties in the physical and cyber parts of the system. PMID:27110785

  3. Predictable and reliable ECG monitoring over IEEE 802.11 WLANs within a hospital.

    PubMed

    Park, Juyoung; Kang, Kyungtae

    2014-09-01

    Telecardiology provides mobility for patients who require constant electrocardiogram (ECG) monitoring. However, its safety is dependent on the predictability and robustness of data delivery, which must overcome errors in the wireless channel through which the ECG data are transmitted. We report here a framework that can be used to gauge the applicability of IEEE 802.11 wireless local area network (WLAN) technology to ECG monitoring systems in terms of delay constraints and transmission reliability. For this purpose, a medical-grade WLAN architecture achieved predictable delay through the combination of a medium access control mechanism based on the point coordination function provided by IEEE 802.11 and an error control scheme based on Reed-Solomon coding and block interleaving. The size of the jitter buffer needed was determined by this architecture to avoid service dropout caused by buffer underrun, through analysis of variations in transmission delay. Finally, we assessed this architecture in terms of service latency and reliability by modeling the transmission of uncompressed two-lead electrocardiogram data from the MIT-BIH Arrhythmia Database and highlight the applicability of this wireless technology to telecardiology.

  4. Residual motion compensation in ECG-gated interventional cardiac vasculature reconstruction

    NASA Astrophysics Data System (ADS)

    Schwemmer, C.; Rohkohl, C.; Lauritsch, G.; Müller, K.; Hornegger, J.

    2013-06-01

    Three-dimensional reconstruction of cardiac vasculature from angiographic C-arm CT (rotational angiography) data is a major challenge. Motion artefacts corrupt image quality, reducing usability for diagnosis and guidance. Many state-of-the-art approaches depend on retrospective ECG-gating of projection data for image reconstruction. A trade-off has to be made regarding the size of the ECG-gating window. A large temporal window is desirable to avoid undersampling. However, residual motion will occur in a large window, causing motion artefacts. We present an algorithm to correct for residual motion. Our approach is based on a deformable 2D-2D registration between the forward projection of an initial, ECG-gated reconstruction, and the original projection data. The approach is fully automatic and does not require any complex segmentation of vasculature, or landmarks. The estimated motion is compensated for during the backprojection step of a subsequent reconstruction. We evaluated the method using the publicly available CAVAREV platform and on six human clinical datasets. We found a better visibility of structure, reduced motion artefacts, and increased sharpness of the vessels in the compensated reconstructions compared to the initial reconstructions. At the time of writing, our algorithm outperforms the leading result of the CAVAREV ranking list. For the clinical datasets, we found an average reduction of motion artefacts by 13 ± 6%. Vessel sharpness was improved by 25 ± 12% on average.

  5. Noninvasive quantification of blood potassium concentration from ECG in hemodialysis patients.

    PubMed

    Corsi, Cristiana; Cortesi, Marilisa; Callisesi, Giulia; De Bie, Johan; Napolitano, Carlo; Santoro, Antonio; Mortara, David; Severi, Stefano

    2017-02-15

    Blood potassium concentration ([K(+)]) influences the electrocardiogram (ECG), particularly T-wave morphology. We developed a new method to quantify [K(+)] from T-wave analysis and tested its clinical applicability on data from dialysis patients, in whom [K(+)] varies significantly during the therapy. To elucidate the mechanism linking [K(+)] and T-wave, we also analysed data from long QT syndrome type 2 (LQT2) patients, testing the hypothesis that our method would have underestimated [K(+)] in these patients. Moreover, a computational model was used to explore the physiological processes underlying our estimator at the cellular level. We analysed 12-lead ECGs from 45 haemodialysis and 12 LQT2 patients. T-wave amplitude and downslope were calculated from the first two eigenleads. The T-wave slope-to-amplitude ratio (TS/A) was used as starting point for an ECG-based [K(+)] estimate (KECG). Leave-one-out cross-validation was performed. Agreement between KECG and reference [K(+)] from blood samples was promising (error: -0.09 ± 0.59 mM, absolute error: 0.46 ± 0.39 mM). The analysis on LQT2 patients, also supported by the outcome of computational analysis, reinforces our interpretation that, at the cellular level, delayed-rectifier potassium current is a main contributor of KECG correlation to blood [K(+)]. Following a comprehensive validation, this method could be effectively applied to monitor patients at risk for hyper/hypokalemia.

  6. Continuous digital ECG analysis over accurate R-peak detection using adaptive wavelet technique.

    PubMed

    Gopalakrishnan Nair, T R; Geetha, A P; Asharani, M

    2013-10-01

    Worldwide, health care segment is under a severe challenge to achieve more accurate and intelligent biomedical systems in order to assist healthcare professionals with more accurate and consistent data as well as reliability. The role of ECG in healthcare is one of the paramount importances and it has got a multitude of abnormal relations and anomalies which characterizes intricate cardiovascular performance image. Until the recent past, ECG instruments and analysis played the role of providing the PQRST signal as raw observational output either on paper or on a console or in a file having many diagnostic clues embedded in the signal left to the expert cardiologist to look out for characteristic intervals and to detect the cardiovascular abnormality. Methods and practises are required more and more, to automate this process of cardiac expertise using knowledge engineering and an intelligent systems approach. This paper presents one of the challenging R-peak detections to classify diagnosis and estimate cardio disorders in a fully automated signal processing sequence. This study used an adaptive wavelet approach to generate an appropriate wavelet for R-signal identification under noise, baseband wandering and temporal variations of R-positions. This study designed an adaptive wavelet and successfully detected R- peak variations under various ECG signal conditions. The result and analysis of this method and the ways to use it for further purposes are presented here.

  7. Closed-Loop Control of Humidification for Artifact Reduction in Capacitive ECG Measurements.

    PubMed

    Leicht, Lennart; Eilebrecht, Benjamin; Weyer, Soren; Leonhardt, Steffen; Teichmann, Daniel

    2017-01-25

    Recording biosignals without the need for direct skin contact offers new opportunities for ubiquitous health monitoring. Electrodes with capacitive coupling have been shown to be suitable for the monitoring of electrical potentials on the body surface, in particular ECG. However, due to triboelectric charge generation and motion artifacts, signal and thus diagnostic quality is inferior to galvanic coupling. Active closed-loop humidification of capacitive electrodes is proposed in this work as a new concept to improve signal quality. A capacitive ECG recording system integrated into a common car seat is presented. It can regulate the micro climate at the interface of electrode and patient by actively dispensing water vapour and monitoring humidity in a closed-loop approach. As a regenerative water reservoir, silica gel is used. The system was evaluated with respect to subjective and objective ECG signal quality. Active humidification was found to have a significant positive effect in case of previously poor quality. Also, it had no diminishing effect in case of already good signal quality.

  8. Mobile Cloud-Computing-Based Healthcare Service by Noncontact ECG Monitoring

    PubMed Central

    Fong, Ee-May; Chung, Wan-Young

    2013-01-01

    Noncontact electrocardiogram (ECG) measurement technique has gained popularity these days owing to its noninvasive features and convenience in daily life use. This paper presents mobile cloud computing for a healthcare system where a noncontact ECG measurement method is employed to capture biomedical signals from users. Healthcare service is provided to continuously collect biomedical signals from multiple locations. To observe and analyze the ECG signals in real time, a mobile device is used as a mobile monitoring terminal. In addition, a personalized healthcare assistant is installed on the mobile device; several healthcare features such as health status summaries, medication QR code scanning, and reminders are integrated into the mobile application. Health data are being synchronized into the healthcare cloud computing service (Web server system and Web server dataset) to ensure a seamless healthcare monitoring system and anytime and anywhere coverage of network connection is available. Together with a Web page application, medical data are easily accessed by medical professionals or family members. Web page performance evaluation was conducted to ensure minimal Web server latency. The system demonstrates better availability of off-site and up-to-the-minute patient data, which can help detect health problems early and keep elderly patients out of the emergency room, thus providing a better and more comprehensive healthcare cloud computing service. PMID:24316562

  9. Design of Secure ECG-Based Biometric Authentication in Body Area Sensor Networks.

    PubMed

    Peter, Steffen; Reddy, Bhanu Pratap; Momtaz, Farshad; Givargis, Tony

    2016-04-22

    Body area sensor networks (BANs) utilize wireless communicating sensor nodes attached to a human body for convenience, safety, and health applications. Physiological characteristics of the body, such as the heart rate or Electrocardiogram (ECG) signals, are promising means to simplify the setup process and to improve security of BANs. This paper describes the design and implementation steps required to realize an ECG-based authentication protocol to identify sensor nodes attached to the same human body. Therefore, the first part of the paper addresses the design of a body-area sensor system, including the hardware setup, analogue and digital signal processing, and required ECG feature detection techniques. A model-based design flow is applied, and strengths and limitations of each design step are discussed. Real-world measured data originating from the implemented sensor system are then used to set up and parametrize a novel physiological authentication protocol for BANs. The authentication protocol utilizes statistical properties of expected and detected deviations to limit the number of false positive and false negative authentication attempts. The result of the described holistic design effort is the first practical implementation of biometric authentication in BANs that reflects timing and data uncertainties in the physical and cyber parts of the system.

  10. Position difference regularity of corresponding R-wave peaks for maternal ECG components from different abdominal points

    NASA Astrophysics Data System (ADS)

    Zhang, Jie-Min; Guan, Qun; Tang, Li-Ming; Liu, Tie-Bing; Liu, Hong-Xing; Huang, Xiao-Lin; Si, Jun-Feng

    2014-01-01

    We collected 343 groups of abdominal electrocardiogram (ECG) data from 78 pregnant women and deleted the channels unable for experts to determine R-wave peaks from them; then, based on these filtered data, the statistics of position difference of corresponding R-wave peaks for different maternal ECG components from different points were studied. The resultant statistics showed the regularity that the position difference of corresponding maternal R-wave peaks between different abdominal points does not exceed the range of 30 ms. The regularity was also proved using the fECG data from MIT—BIH PhysioBank. Additionally, the paper applied the obtained regularity, the range of position differences of the corresponding maternal R-wave peaks, to accomplish the automatic detection of maternal R-wave peaks in the recorded all initial 343 groups of abdominal signals, including the ones with the largest fetal ECG components, and all 55 groups of ECG data from MIT—BIH PhysioBank, achieving the successful separation of the maternal ECGs.

  11. Adaptive spatio-temporal filtering of disturbed ECGs: a multi-channel approach to heartbeat detection in smart clothing.

    PubMed

    Wiklund, Urban; Karlsson, Marcus; Ostlund, Nils; Berglin, Lena; Lindecrantz, Kaj; Karlsson, Stefan; Sandsjö, Leif

    2007-06-01

    Intermittent disturbances are common in ECG signals recorded with smart clothing: this is mainly because of displacement of the electrodes over the skin. We evaluated a novel adaptive method for spatio-temporal filtering for heartbeat detection in noisy multi-channel ECGs including short signal interruptions in single channels. Using multi-channel database recordings (12-channel ECGs from 10 healthy subjects), the results showed that multi-channel spatio-temporal filtering outperformed regular independent component analysis. We also recorded seven channels of ECG using a T-shirt with textile electrodes. Ten healthy subjects performed different sequences during a 10-min recording: resting, standing, flexing breast muscles, walking and pushups. Using adaptive multi-channel filtering, the sensitivity and precision was above 97% in nine subjects. Adaptive multi-channel spatio-temporal filtering can be used to detect heartbeats in ECGs with high noise levels. One application is heartbeat detection in noisy ECG recordings obtained by integrated textile electrodes in smart clothing.

  12. Association of nutrition parameters including bioelectrical impedance and systemic inflammatory response with quality of life and prognosis in patients with advanced non-small-cell lung cancer: a prospective study.

    PubMed

    Sánchez-Lara, Karla; Turcott, Jenny G; Juárez, Eva; Guevara, Patricia; Núñez-Valencia, Carolina; Oñate-Ocaña, Luis F; Flores, Diana; Arrieta, Oscar

    2012-01-01

    Early identification and treatment of nutritional deficiencies can lead to improved outcomes in the quality of life (QoL) and survival of patients with nonsmall cell lung cancer (NSCLC). Noninvasive techniques are needed to evaluate changes in body composition as part of determining nutritional status. The aim of the study was to evaluate the association of nutritional parameters in health-related quality of life (HRQL) and survival in patients with advanced NSCLC. Chemotherapy-naïve patients with advanced NSCLC with good performance status Eastern Cooperative Oncology Group (ECOG) 0-2 were included prospectively in the study. We evaluated inflammatory parameters such as C-reactive protein, platelet/lymphocyte index, neutrophil/lymphocyte index, serum interleukin (IL)-6, and tumor necrosis factor-α, and nutritional variables such as body mass index (BMI) and serum albumin levels. Bioelectrical impedance analysis including phase angle was obtained before cisplatin-based chemotherapy was started. HRQL was assessed by application of the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (QLQ)-C30 and QLQ-LC13 instruments at baseline. Overall survival (OS) was calculated with the Kaplan-Meier method and analyzed with log-rank and Cox proportional hazard models. One hundred nineteen patients were included. Mean BMI was 24.8 ± 4.5 kg/m(2), average weight loss of patients was 8.4%, and median phase angle was 5.8°. Malnutrition measured by subjective global assessment (SGA), weight loss >10%, BMI >20 was associated with lower HRQL scales. Patients with ECOG 2, high content serum IL-6, lower phase angle, and malnutrition parameters showed lower OS; however, after multivariate analysis, only ECOG 2 [Hazard ratio (HR), 2.7; 95% confidence interval (95% CI), 1.5-4.7; P = 0.001], phase angle ≤5.8° (HR = 3.02; 95% CI: 1.2-7.11; P = 0.011), and SGA (HR = 2.7; 95% CI, 1.31-5.5; P = 0.005) were associated with poor survival. Patients

  13. Advanced Biotelemetry Systems for Space Life Sciences: PH Telemetry

    NASA Technical Reports Server (NTRS)

    Hines, John W.; Somps, Chris; Ricks, Robert; Kim, Lynn; Connolly, John P. (Technical Monitor)

    1995-01-01

    The SENSORS 2000! (S2K!) program at NASA's Ames Research Center is currently developing a biotelemetry system for monitoring pH and temperature in unrestrained subjects. This activity is part of a broader scope effort to provide an Advanced Biotelemetry System (ABTS) for use in future space life sciences research. Many anticipated research endeavors will require biomedical and biochemical sensors and related instrumentation to make continuous inflight measurements in a variable-gravity environment. Since crew time is limited, automated data acquisition, data processing, data storage, and subject health monitoring are required. An automated biochemical and physiological data acquisition system based on non invasive or implantable biotelemetry technology will meet these requirements. The ABTS will ultimately acquire a variety of physiological measurands including temperature, biopotentials (e.g. ECG, EEG, EMG, EOG), blood pressure, flow and dimensions, as well as chemical and biological parameters including pH. Development activities are planned in evolutionary, leveraged steps. Near-term activities include 1) development of a dual channel pH/temperature telemetry system, and 2) development of a low bandwidth, 4-channel telemetry system, that measures temperature, heart rate, pressure, and pH. This abstract describes the pH/temperature telemeter.

  14. E-Bra system for women ECG measurement with GPRS communication, Nanosensor, and motion artifact remove algorithm

    NASA Astrophysics Data System (ADS)

    Kwon, Hyeokjun; Oh, Sechang; Kumar, Prashanth S.; Varadan, Vijay K.

    2012-10-01

    CardioVascular Disease(CVD)s lead the sudden cardiac death due to irregular phenomenon of the cardiac signal by the abnormal case of blood vessel and cardiac structure. For last two decades, cardiac disease research for man is under active discussion. As a result, the death rate by cardiac disease in men has been falling gradually compared with relatively increasing the women death rate due to CVD[2]. The main reason of this phenomenon causes the lack a sense of the seriousness to female CVD and different symptom of female CVD compared with the symptoms of male CVD. Usually, because the women CVD accompanies with ordinary symptoms unrecognizing the heart abnormality signal such as unusual fatigue, sleep disturbances, shortness of breath, anxiety, chest discomfort, and indigestion dyspepsia, most women CVD patients do not realize that these symptoms are related to the CVD symptoms. Therefore, periodic ECG signal observation is required for women cardiac disease patients. ElectroCardioGram(ECG) detection, treadmill test/exercise ECG, nuclear scan, coronary angiography, and intracoronary ultrasound are used to diagnose abnormality of heart. Among the medical checkup methods for CVDs checkup, it is very effective method for the diagnosis of cardiac disease and the early detection of heart abnormality to monitor ECG periodically. This paper suggests the effective ECG monitoring system for woman by attaching the system on woman's brassiere by using augmented chest lead attachment method. The suggested system in this paper consists of ECG signal transmission system and a server program to display and analyze the transmitted ECG. The ECG signal transmission system consists of three parts such as ECG physical signal detection part with two electrodes made by gold nanowire structure, data acquisition with AD converter, and data transmission part with GPRS(General Packet Radio Service) communication. Usually, to detect human bio signal, Ag/AgCl or gold cup electrodes are used

  15. Advanced computer techniques for inverse modeling of electric current in cardiac tissue

    SciTech Connect

    Hutchinson, S.A.; Romero, L.A.; Diegert, C.F.

    1996-08-01

    For many years, ECG`s and vector cardiograms have been the tools of choice for non-invasive diagnosis of cardiac conduction problems, such as found in reentrant tachycardia or Wolff-Parkinson-White (WPW) syndrome. Through skillful analysis of these skin-surface measurements of cardiac generated electric currents, a physician can deduce the general location of heart conduction irregularities. Using a combination of high-fidelity geometry modeling, advanced mathematical algorithms and massively parallel computing, Sandia`s approach would provide much more accurate information and thus allow the physician to pinpoint the source of an arrhythmia or abnormal conduction pathway.

  16. To decide medical therapy according to ECG criteria in patients with supraventricular tachycardia in emergency department: adenosine or diltiazem

    PubMed Central

    Dogan, Halil; Ozucelik, Dogac Niyazi; Aciksari, Kurtulus; Caglar, Ilker Murat; Okutan, Nursel; Yazicioglu, Mustafa; Avyaci, Baris Murat; Simsek, Cem; Ozasir, Derya; Giray, Tufan Akin; Ayan, Cem; Celikmen, Feridun; Okuturlar, Yıldız; Sarikaya, Sezgin

    2015-01-01

    The aim of this study is to investigate the effect of ECG criteria which are used for the distinction between AVNRT and AVRT for the choice of treatment in patients with Supraventricular Tachycardia (SVT). The 77 patients with narrow QRS complex SVT which was treated with Adenosine or Diltiazem in the Emergency Department were evaluated retrospectively. All 12-lead ECG during tachycardia were blindly reviewed according to ECG criteria (Pseudo-r` in V1, Pseudo-S-wave in the inferior leads, Visible P-wave, aVL notch) by a cardiologist and an emergency physician. In this study, while 59.6% of the patients returned to normal sinus rhythm (NSR) after the first dose 6 mg, 64.91% of them after the first dose 12 mg and 71.92% of them after the second dose of 12 mg adenosine, 95% of the patients returned to NSR after the 0.25 mg/kg diltiazem. The most visible ECG findings were visible P waves and the least visible ECG findings were Pseudo-S waves in the inferior leads. It was statistically significant between converted by adenosine to NSR and converted by diltiazem to NSR to the presence of visible P-wave and the aVL lead notch in their ECG findings. Conclusion: The rate of return to NSR through diltiazem was found higher than that of adenosine in narrow complex SVT patients. Also, diltiazem may be the first medication to be preferred in the presence of retrograt P wave and aVL notch in the ECG of the patients with narrow QRS complex stable SVT. PMID:26309644

  17. New and Improved T-wave Morphology Parameters to Differentiate Healthy Individuals from those with Cardiomyopathy and Coronary Artery Disease

    NASA Technical Reports Server (NTRS)

    Greco, E. C.; Schlegel, T. T.; Arenare, B.; DePalma, J. L.; Starc, V.; Rahman, M. A.; Delgado, R.

    2007-01-01

    We investigated the ability of several known as well as new ECG repolarization parameters to differentiate healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. The following multiple parameters of T-wave morphology (TWM) were derived via signal averaging and singular value decomposition (SVD, which yields 8 eigenvalues, rho(sub 1) greater than rho(sub 2)...greater than rho(sub 8) and studied for their retrospective accuracy in detecting underlying disease: 1) Principal component analysis ratio of the T wave (T-PCA) = 100*rho(sub 2)/rho(sub 1); 2) Relative T-wave residuum (rTWR) = 100* SIGMA (rho(sub 4)(sup 2) +...+ rho(sub 8)(sup 2)); 3) Modified complexity ratio of the T wave (T-mCR) = 100*SIGMA(rho(sub 3)(sup 2) +...+rho(sb 8) (sup 2)); and 4) Normalized 3-dimensional volume of the T wave (nTV) = 100*(rho(sub 2)*rho(sub 3)/rho(sub 1)(sup 2). All TWM parameters significantly differentiated CAD from controls (p less than 0.0001), and also CM from controls (p less than 0.0001). Retrospective areas under the ROC curve were 0.77, 0.81, 0.82, and 0.83 (CAD vs. controls) and 0.93, 0.89, 0.95 and 0.96 (CM vs. controls) for T-PCA, rTWR, T-mCR and nTV respectively. The newer TWM parameters (T-mCR and nTV) thus outperformed the more established parameters (T-PCA and rTWR), presumably by putting a greater emphasis on the third T-wave eigenvalue, which in most healthy subjects has little energy compared to the first two eigenvalues. Subsequent prospective analyses have also yielded similar results, such that we conclude that diagnostic differentiation of pathology from non-pathology may be especially aided by detecting

  18. Efficiency of superstimulatory protocol P-36 associated with the administration of eCG and LH in Nelore cows.

    PubMed

    Oliveira, A C S; Mattos, M C C; Bastos, M R; Trinca, L A; Razza, E M; Satrapa, R A; Sartori, R; Barros, Ciro M

    2014-09-15

    Recent work with P-36 demonstrates that the replacement of the last two doses of Follicle-Stimulating Hormone (FSH) with equine chorionic gonadotropin (eCG) increases embryo yields. However, it is unclear if the positive effect of eCG is related to its FSH-like activity, LH-like activity, or both. This study aimed to verify the replacement of eCG with pLH on the last day of superstimulatory treatment. Twenty-five Nelore cows were allocated to four groups: P-36 (control), P-36/eCG, P-36/LH2, and P-36/LH4. All animals underwent four treatments in a crossover design. The control group cows were superstimulated with decreasing doses of porcine Follicle-Stimulating Hormone (pFSH, 133 mg, im). In the P-36/eCG, P-36/LH2, and P-36/LH4 groups, the last two doses of pFSH were replaced in the former group by two doses of eCG (200 IU each dose, im) and in the latter two groups by two doses of pLH (1 and 2 mg each dose, im), respectively. Donors received fixed-time artificial insemination 12 and 24 hours after pLH. Embryo flushing was performed on D16. Data were analyzed by ANOVA (Proc Mixed, SAS). There was a trend of decreasing ovulation rate when comparing groups LH2 and eCG (P = 0.06). However, there was no significant difference in the mean number of viable embryos among groups P-36 (3.3 ± 0.7), P-36/eCG (4.5 ± 0.5), P-36/LH2 (3.7 ± 0.8), and P-36/LH4 (4.2 ± 1.0). It is concluded that the replacement of eCG by pLH on the last day of superstimulatory treatment can be performed with no significant variation in the production of viable embryos.

  19. ECG changes in factory workers exposed to 27.2  MHz radiofrequency radiation.

    PubMed

    Chen, Qingsong; Xu, Guoyong; Lang, Li; Yang, Aichu; Li, Shilin; Yang, Liwen; Li, Chaolin; Huang, Hanlin; Li, Tao

    2013-05-01

    To research the effect of 27.2 MHz radiofrequency radiation on electrocardiograms (ECG), 225 female workers operating radiofrequency machines at a shoe factory were chosen as the exposure group and 100 female workers without exposure from the same factory were selected as the control group. The 6 min electric field strength that the female workers were exposed to was 64.0 ± 25.2 V/m (mean ± SD), which exceeded 61 V/m, the International Commission on Non-Ionizing Radiation Protection reference root mean square levels for occupational exposure. A statistical difference was observed between the exposed group and the control group in terms of the rate of sinus bradycardia (χ(2)  = 11.48, P = 0.003). When several known risk factors for cardiovascular disease were considered, including smoking, age, alcohol ingestion habit, and so on, the exposure duration was not an effective factor for ECG changes, sinus arrhythmia, or sinus bradycardia according to α = 0.05, while P = 0.052 for sinus arrhythmia was very close to 0.05. We did not find any statistical difference in heart rate, duration of the QRS wave (ventricular depolarization), or corrected QT intervals (between the start of the Q wave and end of the T wave) between the exposed and control groups. Occupational exposure to radiofrequency radiation was not found to be a cause of ECG changes after consideration of the confounding factors.

  20. Improvements in ECG accuracy for diagnosis of left ventricular hypertrophy in obesity

    PubMed Central

    Rider, Oliver J; Ntusi, Ntobeko; Bull, Sacha C; Nethononda, Richard; Ferreira, Vanessa; Holloway, Cameron J; Holdsworth, David; Mahmod, Masliza; Rayner, Jennifer J; Banerjee, Rajarshi; Myerson, Saul; Watkins, Hugh; Neubauer, Stefan

    2016-01-01

    Objectives The electrocardiogram (ECG) is the most commonly used tool to screen for left ventricular hypertrophy (LVH), and yet current diagnostic criteria are insensitive in modern increasingly overweight society. We propose a simple adjustment to improve diagnostic accuracy in different body weights and improve the sensitivity of this universally available technique. Methods Overall, 1295 participants were included—821 with a wide range of body mass index (BMI 17.1–53.3 kg/m2) initially underwent cardiac magnetic resonance evaluation of anatomical left ventricular (LV) axis, LV mass and 12-lead surface ECG in order to generate an adjustment factor applied to the Sokolow–Lyon criteria. This factor was then validated in a second cohort (n=520, BMI 15.9–63.2 kg/m2). Results When matched for LV mass, the combination of leftward anatomical axis deviation and increased BMI resulted in a reduction of the Sokolow–Lyon index, by 4 mm in overweight and 8 mm in obesity. After adjusting for this in the initial cohort, the sensitivity of the Sokolow–Lyon index increased (overweight: 12.8% to 30.8%, obese: 3.1% to 27.2%) approaching that seen in normal weight (37.8%). Similar results were achieved in the validation cohort (specificity increased in overweight: 8.3% to 39.1%, obese: 9.4% to 25.0%) again approaching normal weight (39.0%). Importantly, specificity remained excellent (>93.1%). Conclusions Adjusting the Sokolow–Lyon index for BMI (overweight +4 mm, obesity +8 mm) improves the diagnostic accuracy for detecting LVH. As the ECG, worldwide, remains the most widely used screening tool for LVH, implementing these findings should translate into significant clinical benefit. PMID:27486142

  1. Noninvasive quantification of blood potassium concentration from ECG in hemodialysis patients

    PubMed Central

    Corsi, Cristiana; Cortesi, Marilisa; Callisesi, Giulia; De Bie, Johan; Napolitano, Carlo; Santoro, Antonio; Mortara, David; Severi, Stefano

    2017-01-01

    Blood potassium concentration ([K+]) influences the electrocardiogram (ECG), particularly T-wave morphology. We developed a new method to quantify [K+] from T-wave analysis and tested its clinical applicability on data from dialysis patients, in whom [K+] varies significantly during the therapy. To elucidate the mechanism linking [K+] and T-wave, we also analysed data from long QT syndrome type 2 (LQT2) patients, testing the hypothesis that our method would have underestimated [K+] in these patients. Moreover, a computational model was used to explore the physiological processes underlying our estimator at the cellular level. We analysed 12-lead ECGs from 45 haemodialysis and 12 LQT2 patients. T-wave amplitude and downslope were calculated from the first two eigenleads. The T-wave slope-to-amplitude ratio (TS/A) was used as starting point for an ECG-based [K+] estimate (KECG). Leave-one-out cross-validation was performed. Agreement between KECG and reference [K+] from blood samples was promising (error: −0.09 ± 0.59 mM, absolute error: 0.46 ± 0.39 mM). The analysis on LQT2 patients, also supported by the outcome of computational analysis, reinforces our interpretation that, at the cellular level, delayed-rectifier potassium current is a main contributor of KECG correlation to blood [K+]. Following a comprehensive validation, this method could be effectively applied to monitor patients at risk for hyper/hypokalemia. PMID:28198403

  2. Irreversible Electroporation Near the Heart: Ventricular Arrhythmias Can Be Prevented With ECG Synchronization

    PubMed Central

    Deodhar, Ajita; Dickfeld, Timm; Single, Gordon W.; Hamilton, William C.; Thornton, Raymond H.; Sofocleous, Constantinos T.; Maybody, Majid; Gónen, Mithat; Rubinsky, Boris; Solomon, Stephen B.

    2013-01-01

    OBJECTIVE Irreversible electroporation is a nonthermal ablative tool that uses direct electrical pulses to create irreversible membrane pores and cell death. The ablation zone is surrounded by a zone of reversibly increased permeability; either zone can cause cardiac arrhythmias. Our purpose was to establish a safety profile for the use of irreversible electroporation close to the heart. MATERIALS and METHODS The effect of unsynchronized and synchronized (with the R wave on ECG) irreversible electroporation in swine lung and myocardium was studied in 11 pigs. Twelve lead ECG recordings were analyzed by an electrophysiologist for the presence of arrhythmia. Ventricular arrhythmias were categorized as major events. Minor events included all other dysrhythmias or ECG changes. Cardiac and lung tissue was submitted for histopathologic analysis. Electrical field modeling was performed to predict the distance from the applicators over which cells show electroporation-induced increased permeability. RESULTS At less than or equal to 1.7 cm from the heart, fatal (major) events occurred with all unsynchronized irreversible electroporation. No major and three minor events were seen with synchronized irreversible electroporation. At more than 1.7 cm from the heart, two minor events occurred with only unsynchronized irreversible electroporation. Electrical field modeling correlates well with the clinical results, revealing increased cell membrane permeability up to 1.7 cm away from the applicators. Complete lung ablation without intervening live cells was seen. No myocardial injury was seen. CONCLUSION Unsynchronized irreversible electroporation close to the heart can cause fatal ventricular arrhythmias. Synchronizing irreversible electroporation pulse delivery with absolute refractory period avoids significant cardiac arrhythmias. PMID:21343484

  3. CSE database: extended annotations and new recommendations for ECG software testing.

    PubMed

    Smíšek, Radovan; Maršánová, Lucie; Němcová, Andrea; Vítek, Martin; Kozumplík, Jiří; Nováková, Marie

    2016-12-31

    Nowadays, cardiovascular diseases represent the most common cause of death in western countries. Among various examination techniques, electrocardiography (ECG) is still a highly valuable tool used for the diagnosis of many cardiovascular disorders. In order to diagnose a person based on ECG, cardiologists can use automatic diagnostic algorithms. Research in this area is still necessary. In order to compare various algorithms correctly, it is necessary to test them on standard annotated databases, such as the Common Standards for Quantitative Electrocardiography (CSE) database. According to Scopus, the CSE database is the second most cited standard database. There were two main objectives in this work. First, new diagnoses were added to the CSE database, which extended its original annotations. Second, new recommendations for diagnostic software quality estimation were established. The ECG recordings were diagnosed by five new cardiologists independently, and in total, 59 different diagnoses were found. Such a large number of diagnoses is unique, even in terms of standard databases. Based on the cardiologists' diagnoses, a four-round consensus (4R consensus) was established. Such a 4R consensus means a correct final diagnosis, which should ideally be the output of any tested classification software. The accuracy of the cardiologists' diagnoses compared with the 4R consensus was the basis for the establishment of accuracy recommendations. The accuracy was determined in terms of sensitivity = 79.20-86.81%, positive predictive value = 79.10-87.11%, and the Jaccard coefficient = 72.21-81.14%, respectively. Within these ranges, the accuracy of the software is comparable with the accuracy of cardiologists. The accuracy quantification of the correct classification is unique. Diagnostic software developers can objectively evaluate the success of their algorithm and promote its further development. The annotations and recommendations proposed in this work will allow

  4. A method for extracting fetal ECG based on EMD-NMF single channel blind source separation algorithm.

    PubMed

    He, Pengju; Chen, Xiaomeng

    2015-01-01

    Nowadays, detecting fetal ECG using abdominal signal is a commonly used method, but fetal ECG signal will be affected by maternal ECG. Current FECG extraction algorithms are mainly aiming at multiple channels signal. They often assume there is only one fetus and did not consider multiple births. This paper proposed a single channel blind source separation algorithm to process single abdominal acquired signal. This algorithm decomposed single abdominal signal into multiple intrinsic mode function (IMF) utilizing empirical mode decomposition (EMD). Correlation matrix of IMF was calculated and independent ECG signal number was estimated using eigenvalue method. Nonnegative matrix was constructed according to determined number and decomposed IMF. Separation of MECG and FECG was achieved utilizing nonnegative matrix factorization (NMF). Experiments selected four channels man-made signal and two channels ECG to verify correctness and feasibility of proposed algorithm. Results showed that the proposed algorithm could determine number of independent signal in single acquired signal. FECG could be extracted from single channel observed signal and the algorithm can be used to solve separation of MECG and FECG.

  5. Compression of ECG signals using variable-length classifıed vector sets and wavelet transforms

    NASA Astrophysics Data System (ADS)

    Gurkan, Hakan

    2012-12-01

    In this article, an improved and more efficient algorithm for the compression of the electrocardiogram (ECG) signals is presented, which combines the processes of modeling ECG signal by variable-length classified signature and envelope vector sets (VL-CSEVS), and residual error coding via wavelet transform. In particular, we form the VL-CSEVS derived from the ECG signals, which exploits the relationship between energy variation and clinical information. The VL-CSEVS are unique patterns generated from many of thousands of ECG segments of two different lengths obtained by the energy based segmentation method, then they are presented to both the transmitter and the receiver used in our proposed compression system. The proposed algorithm is tested on the MIT-BIH Arrhythmia Database and MIT-BIH Compression Test Database and its performance is evaluated by using some evaluation metrics such as the percentage root-mean-square difference (PRD), modified PRD (MPRD), maximum error, and clinical evaluation. Our experimental results imply that our proposed algorithm achieves high compression ratios with low level reconstruction error while preserving the diagnostic information in the reconstructed ECG signal, which has been supported by the clinical tests that we have carried out.

  6. High-resolution detection of sustained ventricular and supraventricular tachycardia through FPGA-based fuzzy processing of ECG signal.

    PubMed

    Roy Chowdhury, Shubhajit

    2015-10-01

    The paper presents a field-programmable gate array (FPGA)-based fast processing system with 12-channel high-resolution (24 bits) front-end for ECG signal processing. The implemented high-resolution data conversion makes the system suitable for recording of late potentials of the QRS complex in patients prone to sustained ventricular tachycardia. The system accepts ECG signals through 12 channels and then filtered to minimize baseline wander and power-line interference. The filter outputs are connected to 12 delta-sigma ADCs. The whole ADCs work synchronously at 8 kHz sampling frequency, and their output data are transferred to an FPGA that computes online on the digitized sample values in real time and ascertains whether the patient under study suffers from ventricular tachycardia or not. In order to ascertain the QRS complex accurately in the noisy ECG signal, fuzzy entropy of the sample values has been computed and provided as an input to inverse multiquadratic radial basis function neural network. Using the standard CSE ECG database, the algorithm performed highly effectively. The performance of the algorithm in respect of QRS detection with sensitivity of 99.83 % and accuracy of 99.7 % is achieved when tested using single-channel ECG with entropy criteria. The performance of the QRS detection system has been compared and found to be better than most of the QRS detection systems available in the literature. Using the system, 200 patients have been diagnosed with an accuracy of 99 %.

  7. Implementation of a wireless ECG acquisition SoC for IEEE 802.15.4 (ZigBee) applications.

    PubMed

    Wang, Liang-Hung; Chen, Tsung-Yen; Lin, Kuang-Hao; Fang, Qiang; Lee, Shuenn-Yuh

    2015-01-01

    This paper presents a wireless biosignal acquisition system-on-a-chip (WBSA-SoC) specialized for electrocardiogram (ECG) monitoring. The proposed system consists of three subsystems, namely, 1) the ECG acquisition node, 2) the protocol for standard IEEE 802.15.4 ZigBee system, and 3) the RF transmitter circuits. The ZigBee protocol is adopted for wireless communication to achieve high integration, applicability, and portability. A fully integrated CMOS RF front end containing a quadrature voltage-controlled oscillator and a 2.4-GHz low-IF (i.e., zero-IF) transmitter is employed to transmit ECG signals through wireless communication. The low-power WBSA-SoC is implemented by the TSMC 0.18-μm standard CMOS process. An ARM-based displayer with FPGA demodulation and an RF receiver with analog-to-digital mixed-mode circuits are constructed as verification platform to demonstrate the wireless ECG acquisition system. Measurement results on the human body show that the proposed SoC can effectively acquire ECG signals.

  8. Administration of eCG on Day 6 postpartum could enhance reproductive performance of Holstein dairy cows.

    PubMed

    Vojgani, M; Akbarinejad, V; Niasari-Naslaji, A

    2013-05-01

    Injection of eCG on Day 6 postpartum could enhance early resumption of ovarian activity in Holstein dairy cows. The present study was conducted to investigate the effects of eCG treatment on Day 6 postpartum on reproductive performance of Holstein dairy cows. Holstein dairy cows (n=420) were randomly assigned to two groups. Cows in eCG-treated group (n=220) received an intramuscular injection of eCG (500IU Folligon®) on Day 6 postpartum, while cows in the Control group (n=200) received no treatment. Estrus expression was observed thrice daily, and AI was carried out 12 hours after standing estrus. Data were analyzed using GLM and Genmod procedures, and survival analysis. Days to first service decreased in the eCG-treated (74.4±1.76 days) compared to the Control (84.2±2.79 days) group (P=0.008). Calving to conception interval was shorter in eCG-treated (103.9±3.14 days) vs Control (130.3±5.70 days) group (P=0.0006). Cows treated with eCG were inseminated and conceived earlier than untreated cows (P<0.05). In conclusion, injection of eCG on Day 6 postpartum improved reproductive performance in Holstein dairy cows.

  9. A computer program for comprehensive ST-segment depression/heart rate analysis of the exercise ECG test.

    PubMed

    Lehtinen, R; Vänttinen, H; Sievänen, H; Malmivuo, J

    1996-06-01

    The ST-segment depression/heart rate (ST/HR) analysis has been found to improve the diagnostic accuracy of the exercise ECG test in detecting myocardial ischemia. Recently, three different continuous diagnostic variables based on the ST/HR analysis have been introduced; the ST/HR slope, the ST/HR index and the ST/HR hysteresis. The latter utilises both the exercise and recovery phases of the exercise ECG test, whereas the two former are based on the exercise phase only. This present article presents a computer program which not only calculates the above three diagnostic variables but also plots the full diagrams of ST-segment depression against heart rate during both exercise and recovery phases for each ECG lead from given ST/HR data. The program can be used in the exercise ECG diagnosis of daily clinical practice provided that the ST/HR data from the ECG measurement system can be linked to the program. At present, the main purpose of the program is to provide clinical and medical researchers with a practical tool for comprehensive clinical evaluation and development of the ST/HR analysis.

  10. Personal Verification/Identification via Analysis of the Peripheral ECG Leads: Influence of the Personal Health Status on the Accuracy

    PubMed Central

    Jekova, Irena; Bortolan, Giovanni

    2015-01-01

    Traditional means for identity validation (PIN codes, passwords), and physiological and behavioral biometric characteristics (fingerprint, iris, and speech) are susceptible to hacker attacks and/or falsification. This paper presents a method for person verification/identification based on correlation of present-to-previous limb ECG leads: I (rI), II (rII), calculated from them first principal ECG component (rPCA), linear and nonlinear combinations between rI, rII, and rPCA. For the verification task, the one-to-one scenario is applied and threshold values for rI, rII, and rPCA and their combinations are derived. The identification task supposes one-to-many scenario and the tested subject is identified according to the maximal correlation with a previously recorded ECG in a database. The population based ECG-ILSA database of 540 patients (147 healthy subjects, 175 patients with cardiac diseases, and 218 with hypertension) has been considered. In addition a common reference PTB dataset (14 healthy individuals) with short time interval between the two acquisitions has been taken into account. The results on ECG-ILSA database were satisfactory with healthy people, and there was not a significant decrease in nonhealthy patients, demonstrating the robustness of the proposed method. With PTB database, the method provides an identification accuracy of 92.9% and a verification sensitivity and specificity of 100% and 89.9%. PMID:26568954

  11. Improving the quality of the ECG signal by filtering in wavelet transform domain

    NASA Astrophysics Data System (ADS)

    DzierŻak, RóŻa; Surtel, Wojciech; Dzida, Grzegorz; Maciejewski, Marcin

    2016-09-01

    The article concerns the research methods of noise reduction occurring in the ECG signals. The method is based on the use of filtration in wavelet transform domain. The study was conducted on two types of signal - received during the rest of the patient and obtained during physical activity. For each of the signals 3 types of filtration were used. The study was designed to determine the effectiveness of various wavelets for de-noising signals obtained in both cases. The results confirm the suitability of the method for improving the quality of the electrocardiogram in case of both types of signals.

  12. Developing new predictive alarms based on ECG metrics for bradyasystolic cardiac arrest.

    PubMed

    Ding, Quan; Bai, Yong; Tinoco, Adelita; Mortara, David; Do, Duc; Boyle, Noel G; Pelter, Michele M; Hu, Xiao

    2015-12-01

    We investigated 17 metrics derived from four leads of electrocardiographic (ECG) signals from hospital patient monitors to develop new ECG alarms for predicting adult bradyasystolic cardiac arrest events.A retrospective case-control study was designed to analyze 17 ECG metrics from 27 adult bradyasystolic and 304 control patients. The 17 metrics consisted of PR interval (PR), P-wave duration (Pdur), QRS duration (QRSdur), RR interval (RR), QT interval (QT), estimate of serum K  +  using only frontal leads (SerumK2), T-wave complexity (T Complex), ST segment levels for leads I, II, V (ST I, ST II, ST V), and 7 heart rate variability (HRV) metrics. These 7 HRV metrics were standard deviation of normal to normal intervals (SDNN), total power, very low frequency power, low frequency power, high frequency power, normalized low frequency power, and normalized high frequency power. Controls were matched by gender, age (±5 years), admission to the same hospital unit within the same month, and the same major diagnostic category. A research ECG analysis software program developed by co-author D M was used to automatically extract the metrics. The absolute value for each ECG metric, and the duration, terminal value, and slope of the dominant trend for each ECG metric, were derived and tested as the alarm conditions. The maximal true positive rate (TPR) of detecting cardiac arrest at a prescribed maximal false positive rate (FPR) based on the trending conditions was reported. Lead time was also recorded as the time between the first time alarm condition was triggered and the event of cardiac arrest.While conditions based on the absolute values of ECG metrics do not provide discriminative information to predict bradyasystolic cardiac arrest, the trending conditions can be useful. For example, with a max FPR  =  5.0%, some derived alarms conditions are: trend duration of PR  >  2.8 h (TPR  =  48.2%, lead time  =  10.0  ±  6.6

  13. DSP implementation of wavelet transform for real time ECG wave forms detection and heart rate analysis.

    PubMed

    Bahoura, M; Hassani, M; Hubin, M

    1997-01-01

    An algorithm based on wavelet transform (WTs) suitable for real time implementation has been developed in order to detect ECG characteristics. In particular, QRS complexes, P and T waves may be distinguished from noise, baseline drift or artefacts. This algorithm is implemented in a DSP (SPROC-1400) with a 50 MHz frequency clock. The performance of this algorithm is discussed, its accuracy is evaluated and a comparison is made with a similar algorithm implemented in C language. For the standard MIT/BIH arrhythmia database, this algorithm correctly detects 99.7% of the QRS complexes.

  14. MicroECG: An Integrated Platform for the Cardiac Arrythmia Detection and Characterization

    NASA Astrophysics Data System (ADS)

    Nascimento, Bruno; Batista, Arnaldo; Alves, Luis Brandão; Ortigueira, Manuel; Rato, Raul

    A software tool for the analysis of the High-Resolution Electrocardiogram (HR-ECG) for Arrhythmia detection is introduced. New algorithms based on Wavelet analysis are presented and compared with the classic Simson protocol over the P and QRS segments of the Electrocardiogram (EEG). A novel procedure based on a two step wavelet analysis and synthesis is performed in order to obtain a frequency description of the P, T or QRS segments. This frequency "signature" is useful for the detection of otherwise asymptomatic Arrhythmia patients. The tool has been developed in Matlab, and deployed for a standalone C application.

  15. A portable system for acquiring and removing motion artefact from ECG signals

    NASA Astrophysics Data System (ADS)

    Griffiths, A.; Das, A.; Fernandes, B.; Gaydecki, P.

    2007-07-01

    A novel electrocardiograph (ECG) signal acquisition and display system is under development. It is designed for patients ranging from the elderly to athletes. The signals are obtained from electrodes integrated into a vest, amplified, digitally processed and transmitted via Bluetooth to a PC with a Labview ® interface. Digital signal processing is performed to remove movement artefact and electromyographic (EMG) noise, which severely distorts signal morphology and complicates clinical diagnosis. Independent component analysis (ICA) is also used to improve the signal quality. The complete system will integrate the electronics into a single module which will be embedded in the vest.

  16. Signal processing using sparse derivatives with applications to chromatograms and ECG

    NASA Astrophysics Data System (ADS)

    Ning, Xiaoran

    In this thesis, we investigate the sparsity exist in the derivative domain. Particularly, we focus on the type of signals which posses up to Mth (M > 0) order sparse derivatives. Efforts are put on formulating proper penalty functions and optimization problems to capture properties related to sparse derivatives, searching for fast, computationally efficient solvers. Also the effectiveness of these algorithms are applied to two real world applications. In the first application, we provide an algorithm which jointly addresses the problems of chromatogram baseline correction and noise reduction. The series of chromatogram peaks are modeled as sparse with sparse derivatives, and the baseline is modeled as a low-pass signal. A convex optimization problem is formulated so as to encapsulate these non-parametric models. To account for the positivity of chromatogram peaks, an asymmetric penalty function is also utilized with symmetric penalty functions. A robust, computationally efficient, iterative algorithm is developed that is guaranteed to converge to the unique optimal solution. The approach, termed Baseline Estimation And Denoising with Sparsity (BEADS), is evaluated and comp