Science.gov

Sample records for aerated lung areas

  1. Cardiopulmonary changes with aeration of the newborn lung.

    PubMed

    Hooper, Stuart Brian; Polglase, Graeme Roger; Roehr, Charles Christoph

    2015-06-01

    The newborn's transition from fetal to neonatal life includes aeration of the lungs, establishment of pulmonary gas exchange and changing the fetal circulation into the adult phenotype. This review summarizes the latest research findings, which show that lung aeration, airway liquid clearance and cardiovascular changes are directly interconnected at birth. The mechanisms of airway liquid clearance at birth are reviewed and the particular importance of the transpulmonary pressure gradient during lung aeration is discussed. Further, we summarize research findings which prove that lung aeration triggers the increase in pulmonary blood flow (PBF) at birth, and how the increase in PBF secures the preload for left ventricular output. Consequently, we review animal experiments which suggest that delaying umbilical cord clamping until breathing commences facilitates hemodynamic stability during transition. These data are reviewed with respect to the clinical applicability: As lung aeration is the key to successful transition to newborn life, providing adequate respiratory support at birth must be the primary objective of neonatal staff attending to the newborn infant. Clinical studies are needed to demonstrate whether the obvious benefits of delaying cord clamping until breathing commences hold true in human babies.

  2. Positive end-expiratory pressure at minimal respiratory elastance represents the best compromise between mechanical stress and lung aeration in oleic acid induced lung injury

    PubMed Central

    Carvalho, Alysson Roncally S; Jandre, Frederico C; Pino, Alexandre V; Bozza, Fernando A; Salluh, Jorge; Rodrigues, Rosana; Ascoli, Fabio O; Giannella-Neto, Antonio

    2007-01-01

    Introduction Protective ventilatory strategies have been applied to prevent ventilator-induced lung injury in patients with acute lung injury (ALI). However, adjustment of positive end-expiratory pressure (PEEP) to avoid alveolar de-recruitment and hyperinflation remains difficult. An alternative is to set the PEEP based on minimizing respiratory system elastance (Ers) by titrating PEEP. In the present study we evaluate the distribution of lung aeration (assessed using computed tomography scanning) and the behaviour of Ers in a porcine model of ALI, during a descending PEEP titration manoeuvre with a protective low tidal volume. Methods PEEP titration (from 26 to 0 cmH2O, with a tidal volume of 6 to 7 ml/kg) was performed, following a recruitment manoeuvre. At each PEEP, helical computed tomography scans of juxta-diaphragmatic parts of the lower lobes were obtained during end-expiratory and end-inspiratory pauses in six piglets with ALI induced by oleic acid. The distribution of the lung compartments (hyperinflated, normally aerated, poorly aerated and non-aerated areas) was determined and the Ers was estimated on a breath-by-breath basis from the equation of motion of the respiratory system using the least-squares method. Results Progressive reduction in PEEP from 26 cmH2O to the PEEP at which the minimum Ers was observed improved poorly aerated areas, with a proportional reduction in hyperinflated areas. Also, the distribution of normally aerated areas remained steady over this interval, with no changes in non-aerated areas. The PEEP at which minimal Ers occurred corresponded to the greatest amount of normally aerated areas, with lesser hyperinflated, and poorly and non-aerated areas. Levels of PEEP below that at which minimal Ers was observed increased poorly and non-aerated areas, with concomitant reductions in normally inflated and hyperinflated areas. Conclusion The PEEP at which minimal Ers occurred, obtained by descending PEEP titration with a protective

  3. Effects of descending positive end-expiratory pressure on lung mechanics and aeration in healthy anaesthetized piglets

    PubMed Central

    Carvalho, Alysson Roncally S; Jandre, Frederico C; Pino, Alexandre V; Bozza, Fernando A; Salluh, Jorge I; Rodrigues, Rosana S; Soares, João HN; Giannella-Neto, Antonio

    2006-01-01

    Introduction Atelectasis and distal airway closure are common clinical entities of general anaesthesia. These two phenomena are expected to reduce the ventilation of dependent lung regions and represent major causes of arterial oxygenation impairment in anaesthetic conditions. The behaviour of the elastance of the respiratory system (Ers), as well as the lung aeration assessed by computed tomography (CT) scan, was evaluated during a descendent positive end-expiratory pressure (PEEP) titration. This work sought to evaluate the potential usefulness of Ers monitoring to set the PEEP in order to prevent tidal recruitment and hyperinflation of healthy lungs under general anaesthesia. Methods PEEP titration (from 16 to 0 cmH2O, tidal volume of 8 ml/kg) was performed, and at each PEEP, CT scans were obtained during end-expiratory and end-inspiratory pauses in six healthy, anaesthetized and paralyzed piglets. The distribution of lung aeration was determined and the tidal re-aeration was calculated as the difference between end-expiratory and end-inspiratory poorly aerated and normally aerated areas. Similarly, tidal hyperinflation was obtained as the difference between end-inspiratory and end-expiratory hyperinflated areas. Ers was estimated from the equation of motion of the respiratory system during all PEEP titration with the least-squares method. Results Hyperinflated areas decreased from PEEP 16 to 0 cmH2O (ranges decreased from 24–62% to 1–7% at end-expiratory pauses and from 44–73% to 4–17% at end-inspiratory pauses) whereas normally aerated areas increased (from 30–66% to 72–83% at end-expiratory pauses and from 19–48% to 73–77% at end-inspiratory pauses). From 16 to 8 cmH2O, Ers decreased with a corresponding reduction in tidal hyperinflation. A flat minimum of Ers was observed from 8 to 4 cmH2O. For PEEP below 4 cmH2O, Ers increased in association with a rise in tidal re-aeration and a flat maximum of the normally aerated areas. Conclusion In

  4. Expired CO2 Levels Indicate Degree of Lung Aeration at Birth

    PubMed Central

    Hooper, Stuart B.; Fouras, Andreas; Siew, Melissa L.; Wallace, Megan J.; Kitchen, Marcus J.; Pas, Arjan B. te.; Klingenberg, Claus; Lewis, Robert A.; Davis, Peter G.; Morley, Colin J.; Schmölzer, Georg M.

    2013-01-01

    As neonatal resuscitation critically depends upon lung aeration at birth, knowledge of the progression of this process is required to guide ongoing care. We investigated whether expired CO2 (ECO2) levels indicate the degree of lung aeration immediately after birth in two animal models and in preterm infants. Lambs were delivered by caesarean section and ventilated from birth. In lambs, ECO2 levels were significantly (p<0.0001) related to tidal volumes and CO2 clearance/breath increased exponentially when tidal volumes were greater than 6 mL/kg. Preterm (28 days of gestation; term = 32 days) rabbits were also delivered by caesarean section and lung aeration was measured using phase contrast X-ray imaging. In rabbit kittens, ECO2 levels were closely related (p<0.001) to lung volumes at end-inflation and were first detected when ∼7% of the distal lung regions were aerated. ECO2 levels in preterm infants at birth also correlated with tidal volumes. In each infant, ECO2 levels increased to >10 mmHg 28 (median) (21–36) seconds before the heart rate increased above 100 beats per minute. These data demonstrate that ECO2 levels can indicate the relative degree of lung aeration after birth and can be used to clinically assess ventilation in the immediate newborn period. PMID:23951032

  5. Spatiotemporal Aeration and Lung Injury Patterns Are Influenced by the First Inflation Strategy at Birth.

    PubMed

    Tingay, David G; Rajapaksa, Anushi; Zonneveld, C Elroy; Black, Don; Perkins, Elizabeth J; Adler, Andy; Grychtol, Bartłomiej; Lavizzari, Anna; Frerichs, Inéz; Zahra, Valerie A; Davis, Peter G

    2016-02-01

    Ineffective aeration during the first inflations at birth creates regional aeration and ventilation defects, initiating injurious pathways. This study aimed to compare a sustained first inflation at birth or dynamic end-expiratory supported recruitment during tidal inflations against ventilation without intentional recruitment on gas exchange, lung mechanics, spatiotemporal regional aeration and tidal ventilation, and regional lung injury in preterm lambs. Lambs (127 ± 2 d gestation), instrumented at birth, were ventilated for 60 minutes from birth with either lung-protective positive pressure ventilation (control) or as per control after either an initial 30 seconds of 40 cm H2O sustained inflation (SI) or an initial stepwise end-expiratory pressure recruitment maneuver during tidal inflations (duration 180 s; open lung ventilation [OLV]). At study completion, molecular markers of lung injury were analyzed. The initial use of an OLV maneuver, but not SI, at birth resulted in improved lung compliance, oxygenation, end-expiratory lung volume, and reduced ventilatory needs compared with control, persisting throughout the study. These changes were due to more uniform inter- and intrasubject gravity-dependent spatiotemporal patterns of aeration (measured using electrical impedance tomography). Spatial distribution of tidal ventilation was more stable after either recruitment maneuver. All strategies caused regional lung injury patterns that mirrored associated regional volume states. Irrespective of strategy, spatiotemporal volume loss was consistently associated with up-regulation of early growth response-1 expression. Our results show that mechanical and molecular consequences of lung aeration at birth are not simply related to rapidity of fluid clearance; they are also related to spatiotemporal pressure-volume interactions within the lung during inflation and deflation.

  6. Aerated Lagoons. Student Manual. Biological Treatment Process Control.

    ERIC Educational Resources Information Center

    Andersen, Lorri

    This student manual contains the textual material for a unit which focuses on the structural and operationally unique features of aerated lagoons. Topic areas discussed include: (1) characteristics of completely mixed aerated lagoons; (2) facultative aerated lagoons; (3) aerated oxidation ponds; (4) effects of temperature on aerated lagoons; (5)…

  7. [Ethylene oxide residues and aeration time after use of modern heated aerators (author's transl)].

    PubMed

    Star, E G

    1980-06-01

    The aeration time after ethylene oxide sterilization is rather long, particularly for PVC materials. It can be shortened enormously by heated aerators with continuous air exchange. We used different aeration methods and determined the ethylene oxide residues in endotracheal tubes, nasal and oro-pharyngeal airways, breathing tubes, parts of heart-lung-machines as well as gastroscope- and bronchoscope linings. The analyses were performed with a Hewlett-Packard gas chromatograph by the head space method. Intermittent vacuum with air irrigation was not as effective as continuous air exchange in heated aerators. The aeration time in these at 37 degrees C is longer than with 62 degrees C. After degassing in aerators with 62 degrees C the sterilized items can be used the next day already. Aerators blow the released ethylene oxide residues into the open air. The personnel is exposed to considerably smaller ethylene oxide concentrations because the long aeration time at room temperature in storage places is now eliminated.

  8. Applying fine bubble aeration to small aeration tanks.

    PubMed

    Duchène, P; Cotteux, E; Capela, S

    2001-01-01

    Because the aeration system in an activated sludge plant typically represents a large part of the total energy requirements, designers and operators need accurate oxygen transfer information to make the aeration system as energy efficient as possible. This paper presents clean water tests performed at 38 wastewater treatment plants. The Specific Aeration Efficiency results (SAE, kgO2/kWh) are reported for: (1) large open channels (volume higher than 1000 m3), (2) small open channels, (3) total floor coverage cylindrical tanks, and (4) cylindrical tanks with a grid arrangement. Some practical guidelines can be drawn, some of them being: (1) high SAE can be achieved at small aeration tanks (< 1000 m3), applying cylindrical tanks with a total floor coverage arrangement of diffusers, volumetric blowers, and moderate air flow rates per diffuser area; (2) the high investment cost of this configuration can be justified with respect to a grid layout characterized by spiral liquid circulation which affects the oxygen transfer; (3) small open channels can meet sufficient SAE values but fail to meet in this range of tank volumes those of total floor coverage cylindrical tanks.

  9. USING AERATION FOR CORROSION CONTROL

    EPA Science Inventory

    Aeration is a useful drinking water treatment process. Aeration has been used to remove hydrogen sulfide, methane, radon, iron, manganese, and volatile organic contaminants (VOCs) from drinking water. Aeration is also effective in removing carbon dioxide which directly impacts ...

  10. Measurements of Deposition, Lung Surface Area and Lung Fluid for Simulation of Inhaled Compounds

    PubMed Central

    Fröhlich, Eleonore; Mercuri, Annalisa; Wu, Shengqian; Salar-Behzadi, Sharareh

    2016-01-01

    Modern strategies in drug development employ in silico techniques in the design of compounds as well as estimations of pharmacokinetics, pharmacodynamics and toxicity parameters. The quality of the results depends on software algorithm, data library and input data. Compared to simulations of absorption, distribution, metabolism, excretion, and toxicity of oral drug compounds, relatively few studies report predictions of pharmacokinetics and pharmacodynamics of inhaled substances. For calculation of the drug concentration at the absorption site, the pulmonary epithelium, physiological parameters such as lung surface and distribution volume (lung lining fluid) have to be known. These parameters can only be determined by invasive techniques and by postmortem studies. Very different values have been reported in the literature. This review addresses the state of software programs for simulation of orally inhaled substances and focuses on problems in the determination of particle deposition, lung surface and of lung lining fluid. The different surface areas for deposition and for drug absorption are difficult to include directly into the simulations. As drug levels are influenced by multiple parameters the role of single parameters in the simulations cannot be identified easily. PMID:27445817

  11. Trends in Lung Cancer Incidence in a Healthcare Area.

    PubMed

    Molina, Antonio J; García-Martínez, Lidia; Zapata-Alvarado, Julio; Alonso-Orcajo, Nieves; Fernández-Villa, Tania; Martín, Vicente

    2015-11-01

    The aim of this study was to identify trends in the incidence of lung cancer in the Leon Healthcare Area. All cases of cancer among residents of the Leon healthcare catchment area listed in the hospital-based tumor registry of the Centro Asistencial Universitario de Leon (CAULE) between 1996 and 2010 were included. Gross incidence rates over 3-year intervals were calculated and adjusted for the worldwide and European populations. A total of 2,491 cases were included. In men, incidence adjusted for the European population rose from 40.1 new cases per 100,000 population (1996-1998) to 61.8 (2005-2007), and then fell to 54.6 (2008-2010). In women, incidence tripled from 3.0 (1996-1998) to 9.2 new cases per 100,000 (2008-2010). Although lung cancer is an avoidable disease, it is a serious problem in the Leon Healthcare Area. Of particular concern is the rising incidence among women. PMID:26153559

  12. Trends in Lung Cancer Incidence in a Healthcare Area.

    PubMed

    Molina, Antonio J; García-Martínez, Lidia; Zapata-Alvarado, Julio; Alonso-Orcajo, Nieves; Fernández-Villa, Tania; Martín, Vicente

    2015-11-01

    The aim of this study was to identify trends in the incidence of lung cancer in the Leon Healthcare Area. All cases of cancer among residents of the Leon healthcare catchment area listed in the hospital-based tumor registry of the Centro Asistencial Universitario de Leon (CAULE) between 1996 and 2010 were included. Gross incidence rates over 3-year intervals were calculated and adjusted for the worldwide and European populations. A total of 2,491 cases were included. In men, incidence adjusted for the European population rose from 40.1 new cases per 100,000 population (1996-1998) to 61.8 (2005-2007), and then fell to 54.6 (2008-2010). In women, incidence tripled from 3.0 (1996-1998) to 9.2 new cases per 100,000 (2008-2010). Although lung cancer is an avoidable disease, it is a serious problem in the Leon Healthcare Area. Of particular concern is the rising incidence among women.

  13. Catfish production using intensive aeration

    Technology Transfer Automated Retrieval System (TEKTRAN)

    For the last 3 years, researchers at UAPB and NWAC have been monitoring and verifying production yields in intensively aerated catfish ponds with aeration rates greater than 6 hp/acre. We now have three years of data on commercial catfish production in intensively aerated ponds. With stocking densi...

  14. Landfill aeration worldwide: Concepts, indications and findings

    SciTech Connect

    Ritzkowski, M.; Stegmann, R.

    2012-07-15

    Highlights: Black-Right-Pointing-Pointer Different landfill aeration concepts and accordant application areas are described. Black-Right-Pointing-Pointer Examples of full scale projects are provided for Europe, North-America and Asia. Black-Right-Pointing-Pointer Major project findings are summarised, including prospects and limitations. Black-Right-Pointing-Pointer Inconsistencies between laboratory and full scale results have been elaborated. Black-Right-Pointing-Pointer An explanatory approach in connection with the inconsistencies is provided. - Abstract: The creation of sustainable landfills is a fundamental goal in waste management worldwide. In this connection landfill aeration contributes towards an accelerated, controlled and sustainable conversion of conventional anaerobic landfills into a biological stabilized state associated with a minimised emission potential. The technology has been successfully applied to landfills in Europe, North America and Asia, following different strategies depending on the geographical region, the specific legislation and the available financial resources. Furthermore, methodologies for the incorporation of landfill aeration into the carbon trade mechanisms have been developed in recent years. This manuscript gives an overview on existing concepts for landfill aeration; their application ranges and specifications. For all of the described concepts examples from different countries worldwide are provided, including details regarding their potentials and limitations. Some of the most important findings from these aeration projects are summarised and future research needs have been identified. It becomes apparent that there is a great demand for a systematisation of the available results and implications in order to further develop and optimise this very promising technology. The IWWG (International Waste Working Group) Task Group 'Landfill Aeration' contributes towards the achievement of this goal.

  15. Soil Aeration deficiencies in urban sites

    NASA Astrophysics Data System (ADS)

    Weltecke, Katharina; Gaertig, Thorsten

    2010-05-01

    root density and tree vigour on urban soils. For that purpose gas diffusivity, soil CO2 concentrations and fine root density were measured on typical urban sites in the German cities of Göttingen, Mannheim, and Kassel. The known characteristics of soil aeration on forest sites could be affirmed for urban soils. A negative correlation was found between gas diffusion coefficients and CO2 concentration as well as between fine root extension and CO2 concentration. Changes in crown structure of beech indicating a loss of vigour were found at sites with disturbed aeration. Diffusivity patterns and CO2 concentrations of different specific urban soil sealing types were found. On more natural sites (mulch, grass) increased gas diffusion and low CO2 concentration were present. In contrast, on more compacted or sealed areas (asphalt, paving stone, macadamised road surface) the exchange between soil air and atmosphere was nearly disconnected and soil CO2 concentrations partly exceeded the known critical value of 0.6 % up to tenfold. Literature Burton, A. J.; Pregitzer, K. S.; Zogg, G. P. und Zak D. R. (1997): Effect of measurement CO2 concentrations on sugar maple root respiration. In: Canadian journal of Forest Research, H. 17, S. 421-427. Gaertig, T. (2001): Bodengashaushalt, Feinwurzeln und Vitalität von Eichen. In: Freiburger Bodenkundliche Abhandlungen, H. 40, S. 157. Qi, J.; Marshall, J. D.; Mattson, K. G. (1994): High soil carbon dioxide concentrations inhibit root respiration of Douglas fir. In: New Phytol., Jg. 128, H. 3, S. 435-442. Schack-Kirchner, H.; Gaertig, T.; Wilpert, K. v.; Hildebrand, E. E. (2001): A modified McIntyre and Phillip approach to measure top-soil gas diffusivity in-situ. In: J. Plant Nutr. Soil Sci., Jg. 164, S. 253-258.

  16. Novel method of lung area extraction in chest perfusion computed tomography.

    PubMed

    Kalicka, Renata; Lipiński, Seweryn; Browarczyk, Maciej

    2013-02-01

    Chest perfusion computed tomography (pCT) is a useful technique in the medical diagnosis of how organs function. Perfusion CT scans are used to calculate perfusion parameters. In the case of automated methods of lung perfusion parameters calculation, the prior extraction of the lung area is desired to avoid unnecessary calculation in an area outside the lung cross-section and to avoid wasting time on processing signals of no diagnostic importance. Our new method is designed to extract a lung cross-section from a whole series of chest pCT images. It uses a complete sequence of pCT scans to extract the rough lung contour. Next each scan is processed individually, within the rough contour, to obtain a detailed, individual outline of the lungs. The proposed method and obtained results are presented and compared with methods known in literature.

  17. Lung cancer care: the impact of facilities and area measures

    PubMed Central

    2015-01-01

    Lung cancer is the leading cause of cancer related mortality in the US, and while treatment disparities by race and class have been well described in the literature, the impact of social determinates of health, and specific characteristics of the treatment centers have been less well characterized. As the treatment of lung cancer relies more upon a precision and personalized medicine approach, where patients obtain treatment has an impact on outcomes and could be a major factor in treatment disparities. The purpose of this manuscript is to discuss the manner in which lung cancer care can be impacted by poor access to high quality treatment centers, and how the built environment can be a mitigating factor in the pursuit of treatment equity. PMID:26380179

  18. Dust and Fibrosis in the Lungs of Coal-Workers from the Wigan Area of Lancashire

    PubMed Central

    Spink, R.; Nagelschmidt, G.

    1963-01-01

    During the years 1953 to 1957 more than 1,000 lungs of coal-workers in the Wigan area were examined and compared with lungs from workers in South Wales. The Wigan lungs in general appeared to be less dusty and progressive massive fibrosis less frequent than in the South Wales lungs. Also, the more advanced cases of progressive massive fibrosis appeared to be of a silicotic type. Of these lungs, 100 were selected for study of the relation of the type and severity of pneumoconiosis to right ventricular hypertrophy, using Gough-Wentworth sections. The remaining tissues from 47 of these lungs were used for an analysis of the content and composition of the dust and its relation to the grade of fibrosis. The average coal and quartz percentages of the dust from the lungs in the Wigan area were similar to previous findings in lungs from the Cumberland coalfield but differed from those in South Wales where the lung dust has a higher coal and a lower quartz percentage. Two possible explanations for this finding are discussed. Images PMID:13990155

  19. Lung deposited surface area size distributions of particulate matter in different urban areas

    NASA Astrophysics Data System (ADS)

    Kuuluvainen, Heino; Rönkkö, Topi; Järvinen, Anssi; Saari, Sampo; Karjalainen, Panu; Lähde, Tero; Pirjola, Liisa; Niemi, Jarkko V.; Hillamo, Risto; Keskinen, Jorma

    2016-07-01

    Lung deposited surface area (LDSA) concentration is considered as a relevant metric for the negative health effects of aerosol particles. We report for the first time the size distributions of the LDSA measured in urban air. The measurements were carried out in the metropolitan area of Helsinki, including mobile laboratory and stationary measurements in different outdoor environments, such as traffic sites, a park area, the city center and residential areas. The main instrument in this study was an electrical low pressure impactor (ELPI), which was calibrated in the field to measure the LDSA concentration. The calibration factor was determined to be 60 μm2/(cm3 pA). In the experiments, the LDSA size distributions were found to form two modes at the traffic sites and in the city center. Both of these traffic related particle modes, the nucleation mode and the soot mode, had a clear contribution to the total LDSA concentration. The average total concentrations varied from 12 to 94 μm2/cm3, measured in the park area and at the traffic site next to a major road, respectively. The LDSA concentration was found to correlate with the mass of fine particles (PM2.5), but the relation of these two metrics varied between different environments, emphasizing the influence of traffic on the LDSA. The results of this study provide valuable information on the total concentrations and size distributions of the LDSA for epidemiological studies. The size distributions are especially important in estimating the contribution of outdoor concentrations on the concentrations inside buildings and vehicles through size-dependent penetration factors.

  20. Aeration equipment for small depths

    NASA Astrophysics Data System (ADS)

    Sluše, Jan; Pochylý, František

    2015-05-01

    Deficit of air in water causes complications with cyanobacteria mainly in the summer months. Cyanobacteria is a bacteria that produces poison called cyanotoxin. When the concentration of cyanobacteria increases, the phenomena "algal bloom" appears, which is very toxic and may kill all the organisms. This article describes new equipment for aeration of water in dams, ponds and reservoirs with small depth. This equipment is mobile and it is able to work without any human factor because its control is provided by a GPS module. The main part of this equipment consists of a floating pump which pumps water from the surface. Another important part of this equipment is an aerator where water and air are blended. Final aeration process runs in the nozzles which provide movement of all this equipment and aeration of the water. Simulations of the flow are solved by multiphase flow with diffusion in open source program called OpenFOAM. Results will be verified by an experiment.

  1. Experimental investigations of aeration efficiency in high-head gated circular conduits.

    PubMed

    Cihat Tuna, M; Ozkan, Fahri; Baylar, Ahmet

    2014-01-01

    The primary purpose of water aeration is to increase the oxygen saturation of the water. This can be achieved by using hydraulic structures because of substantial air bubble entrainment at these structures. Closed conduit aeration is a particular instance of this. While there has been a great deal of research on air-demand ratio within closed conduit, very little research has specifically addressed aeration efficiency of closed conduit. In the present work an experimental study was conducted to investigate the aeration efficiency of high-head gated circular conduits. Results showed that high-head gated circular conduits were effective for oxygen transfer. The effects of Froude number and ratio of the water cross-sectional flow area to the conduit cross-sectional area on aeration efficiency were particularly significant, whereas the effect of conduit length was only moderate. Further, a design formula for the aeration efficiency was presented relating the aeration efficiency to ratio of water cross-sectional flow area to conduit cross-sectional area and Froude number. The obtained results will be useful in future modeling processes and aid the practicing engineer in predicting aeration efficiency for design purposes.

  2. Aeration-Induced Changes in Temperature and Nitrogen Dynamics in a Dimictic Lake.

    PubMed

    Holmroos, Heidi; Horppila, Jukka; Laakso, Sanna; Niemistö, Juha; Hietanen, Susanna

    2016-07-01

    Low levels of oxygen (O) in the hypolimnion layer of lakes are harmful to benthic animals and fish; they may also adversely affect nutrient cycles. Artificial aeration is often used in lake management to counteract these problems, but the effects of aeration on nitrogen (N) cycling are not known. We studied the effects of hypolimnetic aeration on N dynamics and temperature in a eutrophic lake by comparing continuous and pulsed aeration with a nonaerated station. Aeration decreased the accumulation of NH-N deep in the lake (20-33 m) by supplying O for nitrification, which in turn provided substrate for denitrification and promoted N removal. Aeration also increased the temperature in the hypolimnion. Denitrification rate was highest in the nonaerated deep areas (average, 7.62 mg N m d) due to very high rates during spring turnover of the water column, demonstrating that natural turnover provides O for nitrification. During stratification, denitrification was highest at the continuously aerated station (4.06 mg N m d) and lowest at the nonaerated station (3.02 mg N m d). At the periodically aerated station, aeration pauses did not restrict the increase in temperature but resulted in accumulation of NH-N and decreased the contribution of denitrification as a nitrate reduction process. Our findings demonstrate that hypolimnetic aeration can substantially affect N cycling in lakes and that the effect depends on the aeration strategy. Because N is one of the main nutrients controlling eutrophication, the effects of aeration methods on N removal should be considered as part of strategies to manage water quality in lakes.

  3. Aeration-Induced Changes in Temperature and Nitrogen Dynamics in a Dimictic Lake.

    PubMed

    Holmroos, Heidi; Horppila, Jukka; Laakso, Sanna; Niemistö, Juha; Hietanen, Susanna

    2016-07-01

    Low levels of oxygen (O) in the hypolimnion layer of lakes are harmful to benthic animals and fish; they may also adversely affect nutrient cycles. Artificial aeration is often used in lake management to counteract these problems, but the effects of aeration on nitrogen (N) cycling are not known. We studied the effects of hypolimnetic aeration on N dynamics and temperature in a eutrophic lake by comparing continuous and pulsed aeration with a nonaerated station. Aeration decreased the accumulation of NH-N deep in the lake (20-33 m) by supplying O for nitrification, which in turn provided substrate for denitrification and promoted N removal. Aeration also increased the temperature in the hypolimnion. Denitrification rate was highest in the nonaerated deep areas (average, 7.62 mg N m d) due to very high rates during spring turnover of the water column, demonstrating that natural turnover provides O for nitrification. During stratification, denitrification was highest at the continuously aerated station (4.06 mg N m d) and lowest at the nonaerated station (3.02 mg N m d). At the periodically aerated station, aeration pauses did not restrict the increase in temperature but resulted in accumulation of NH-N and decreased the contribution of denitrification as a nitrate reduction process. Our findings demonstrate that hypolimnetic aeration can substantially affect N cycling in lakes and that the effect depends on the aeration strategy. Because N is one of the main nutrients controlling eutrophication, the effects of aeration methods on N removal should be considered as part of strategies to manage water quality in lakes. PMID:27380085

  4. Enhanced long-term organics and nitrogen removal and associated microbial community in intermittently aerated subsurface flow constructed wetlands.

    PubMed

    Fan, Jinlin; Zhang, Jian; Guo, Wenshan; Liang, Shuang; Wu, Haiming

    2016-08-01

    The long-term enhanced removal efficiency of organics and nitrogen in subsurface flow constructed wetlands (SSF CWs) with and without intermittent aeration for decentralized domestic wastewater was evaluated, and the function of intermittent aeration on microbial community was also investigated in this study. The high and long-term 95.6% COD, 96.1% NH4(+)-N and 85.8% TN removal efficiencies were achieved in experimental intermittently aerated SSF CW compared with non-aerated SSF CW. Aerated SSF CWs also exhibited the excellent removal performance when comparatively comparing with other strategies and techniques applied in CWs. In addition, fluorescence in situ hybridization (FISH) analysis revealed that associated microbial abundance significantly increased owing to intermittent aeration. These results indicated intermittent aeration CWs might be an effective and sustainable strategy for wastewater treatment in rural areas, but require further full-scale investigation in future.

  5. Tracer studies on an aerated lagoon.

    PubMed

    Broughton, Alistair; Shilton, Andy

    2012-01-01

    The city of Palmerston North, New Zealand, has two aerated lagoons as its secondary treatment facility. Interest about treatment efficiency led to an investigation into the hydraulics in the second lagoon to determine if further optimisation was viable. A tracer study using rhodamine WT was undertaken to ascertain the stimulus response output. Samples were also taken at 24 points within the lagoon to determine the tracer concentration profile throughout the lagoon. The mean residence time was determined to be 39.9 h compared with a theoretical residence time of 55.4 h. Peak concentration of the tracer at the outlet occurred at 0.44 of the mean residence time. The results of the tracer study pointed to 28% of volume being dead space. A subsequent sludge survey indicated that 26% of the design volume of the lagoon was filled with sludge. While the curved geometry of the lagoon did not appear to impact the hydraulics the fact that the first aerator is confined in a relatively smaller area will have locally boosted the mixing energy input in this inlet zone. From interpretation of the tracer response and the tracer distribution profiles it appears that the aerators are mixing the influent into the bulk flow effectively in the front end of the lagoon and that there was no evidence of any substantive short-circuiting path of concentrated tracer around to the outlet. The tracer distribution profiles gave direct insight as to how the tracer was being transported within the pond and should be used more often when conducting tracer studies. Comparison with the literature indicated that the lagoon's hydraulic efficiency was on par with a baffled pond system and it would be expected that addition of several baffles to the lagoon would provide minimal further improvement. PMID:22277219

  6. Landfill aeration for emission control before and during landfill mining.

    PubMed

    Raga, Roberto; Cossu, Raffaello; Heerenklage, Joern; Pivato, Alberto; Ritzkowski, Marco

    2015-12-01

    The landfill of Modena, in northern Italy, is now crossed by the new high velocity railway line connecting Milan and Bologna. Waste was completely removed from a part of the landfill and a trench for the train line was built. With the aim of facilitating excavation and further disposal of the material extracted, suitable measures were defined. In order to prevent undesired emissions into the excavation area, the aerobic in situ stabilisation by means of the Airflow technology took place before and during the Landfill Mining. Specific project features involved the pneumatic leachate extraction from the aeration wells (to keep the leachate table low inside the landfill and increase the volume of waste available for air migration) and the controlled moisture addition into a limited zone, for a preliminary evaluation of the effects on process enhancement. Waste and leachate were periodically sampled in the landfill during the aeration before the excavation, for quality assessment over time; the evolution of biogas composition in the landfill body and in the extraction system for different plant set-ups during the project was monitored, with specific focus on uncontrolled migration into the excavation area. Waste biological stability significantly increased during the aeration (waste respiration index dropped to 33% of the initial value after six months). Leachate head decreased from 4 to 1.5m; leachate recirculation tests proved the beneficial effects of moisture addition on temperature control, without hampering waste aerobization. Proper management of the aeration plant enabled the minimization of uncontrolled biogas emissions into the excavation area.

  7. Correlation between lung to thorax transverse area ratio and observed/expected lung area to head circumference ratio in fetuses with left-sided diaphragmatic hernia.

    PubMed

    Hidaka, Nobuhiro; Murata, Masaharu; Sasahara, Jun; Ishii, Keisuke; Mitsuda, Nobuaki

    2015-05-01

    Observed/expected lung area to head circumference ratio (o/e LHR) and lung to thorax transverse area ratio (LTR) are the sonographic indicators of postnatal outcome in fetuses with congenital diaphragmatic hernia (CDH), and they are not influenced by gestational age. We aimed to evaluate the relationship between these two parameters in the same subjects with fetal left-sided CDH. Fetuses with left-sided CDH managed between 2005 and 2012 were included. Data of LTR and o/e LHR values measured on the same day prior to 33 weeks' gestation in target fetuses were retrospectively collected. The correlation between the two parameters was estimated using the Spearman's rank-correlation coefficient, and linear regression analysis was used to assess the relationship between them. Data on 61 measurements from 36 CDH fetuses were analyzed to obtain a Spearman's rank-correlation coefficient of 0.74 with the following linear equation: LTR = 0.002 × (o/e LHR) + 0.005. The determination coefficient of this linear equation was sufficiently high at 0.712, and the prediction accuracy obtained with this regression formula was considered satisfactory. A good linear correlation between the LTR and the o/e LHR was obtained, suggesting that we can translate the predictive parameters for each other. This information is expected to be useful to improve our understanding of different investigations focusing on LTR or o/e LHR as a predictor of postnatal outcome in CDH. PMID:25353722

  8. Aeration for plant root respiration in a tidal marsh

    NASA Astrophysics Data System (ADS)

    Li, Hailong; Li, Ling; Lockington, David

    2005-06-01

    This paper investigates the tidal effects on aeration conditions for plant root respiration in a tidal marsh. We extend the work of Ursino et al. (2004) by using a two-phase model for air and water flows in the marsh. Simulations have been conducted to examine directly the link between the airflow dynamics and the aeration condition in the marsh soil. The results show that the effects of entrapped air on water movement in the vadose zone are significant in certain circumstances. Single-phase models based on Richards' equation, which neglect such effects, may not be adequate for quantifying the aeration condition in tidal marsh. The optimal aeration condition, represented by the maximum of the integral magnitude of tidally advected air mass (TAAM) flux, is found to occur near the tidal creek for the four soil textures simulated. This may explain the observation that some salt marsh plant species grow better near tidal creeks than in the inner marsh areas. Our analyses, based on the two-phase model and predicted TAAM flux magnitude, provide further insight into the "positive feedback" mechanism proposed by Ursino et al. (2004). That is, pioneer plants may grow successfully near the creek where the root aeration condition is optimal. The roots of the pioneer plants can soften and loosen the rhizosphere soil, which increases the evapotranspiration rate, the soil porosity, and absolute permeability and weakens the capillary effects. These, in turn, improve further the root aeration conditions and may lead to colonization by plants less resistant to anaerobic conditions.

  9. Aeration for plant root respiration in a tidal marsh

    NASA Astrophysics Data System (ADS)

    Li, Hailong; Li, Ling; Lockington, David

    2005-06-01

    This paper investigates the tidal effects on aeration conditions for plant root respiration in a tidal marsh. We extend the work of Ursino et al. (2004) by using a two-phase model for air and water flows in the marsh. Simulations have been conducted to examine directly the link between the airflow dynamics and the aeration condition in the marsh soil. The results show that the effects of entrapped air on water movement in the vadose zone are significant in certain circumstances. Single-phase models based on Richards' equation, which neglect such effects, may not be adequate for quantifying the aeration condition in tidal marsh. The optimal aeration condition, represented by the maximum of the integral magnitude of tidally advected air mass (TAAM) flux, is found to occur near the tidal creek for the four soil textures simulated. This may explain the observation that some salt marsh plant species grow better near tidal creeks than in the inner marsh areas. Our analyses, based on the two-phase model and predicted TAAM flux magnitude, provide further insight into the ``positive feedback'' mechanism proposed by Ursino et al. (2004). That is, pioneer plants may grow successfully near the creek where the root aeration condition is optimal. The roots of the pioneer plants can soften and loosen the rhizosphere soil, which increases the evapotranspiration rate, the soil porosity, and absolute permeability and weakens the capillary effects. These, in turn, improve further the root aeration conditions and may lead to colonization by plants less resistant to anaerobic conditions.

  10. Patients with MAC Lung Disease Have a Low Visceral Fat Area and Low Nutrient Intake

    PubMed Central

    Wakamatsu, Kentaro; Nagata, Nobuhiko; Maki, Sanae; Omori, Hisamitsu; Kumazoe, Hiroyuki; Ueno, Kayoko; Matsunaga, Yuko; Hara, Makiko; Takakura, Koji; Fukumoto, Nagisa; Ando, Nobuhisa; Morishige, Mami; Akasaki, Takashi; Inoshima, Ichiro; Ise, Shinji; Izumi, Miiru; Kawasaki, Masayuki

    2015-01-01

    Objective. This study aimed to examine the nutritional status and nutrient intake of patients with MAC lung disease with a focus on visceral fat area. Patients and Methods. Among 116 patients of our hospital with nontuberculous mycobacteriosis who were registered between May 2010 and August 2011, 103 patients with MAC lung disease were included in this study. In all patients, nutritional status and nutrient intake were prospectively examined. Results. Patients were 23 men and 80 women (mean age, 72.3 ± 10.9 years). BMI (kg/m2) at the time of registration was 20.4 ± 2.7 in men and 19.2 ± 2.9 in women. Visceral fat area (cm2) was significantly lower in women (35.7 ± 26.6) than in men (57.5 ± 47.4) (p = 0.0111). The comparison with general healthy adults according to age revealed a markedly reduced visceral fat area among patients with MAC lung disease. With respect to nutrient intake, energy adequacy (86.1 ± 15.7%), protein adequacy (82.4 ± 18.2%), lipid adequacy (78.1 ± 21.8%), and carbohydrate adequacy (89.6 ± 19.2%) ratios were all low at the time of registration. BMI was significantly correlated with protein adequacy (p = 0.0397) and lipid adequacy (p = 0.0214) ratios, while no association was found between visceral fat area and nutrient intake. Conclusion. Patients with MAC lung disease had a low visceral fat area and low nutrient intake. PMID:26693350

  11. Collapsed Lung

    MedlinePlus

    A collapsed lung happens when air enters the pleural space, the area between the lung and the chest wall. If it is a ... is called pneumothorax. If only part of the lung is affected, it is called atelectasis. Causes of ...

  12. Lung cancer excess in an abandoned lead-zinc mining and smelting area.

    PubMed

    Neuberger, J S; Hollowell, J G

    1982-11-01

    Analysis of cancer mortality in whites has revealed a significant excess in both males and females in an old lead/zinc mining and smelting area. This area consists of three rural contiguous counties: Cherokee County, Kansas, Jasper County, Missouri, and Ottawa County, Oklahoma. The lung cancer excess has persisted for at least 28 years for males and 5 years for females. A pilot case/control study is underway in Cherokee County to assess the influence of cigarette smoking, occupation, and residence on the lung cancer excess. Analysis will incorporate the histologic findings. From an environmental perspective, there are numerous mine tailings containing lead, zinc, cadmium, sulfur, germanium, and other chemicals. Considerable dust is airborne. Numerous openings (sink holes and bore holes) connect the old mines with the surface. Radium 226 has been detected in the untreated groundwater. PMID:7156973

  13. Lung cancer excess in an abandoned lead-zinc mining and smelting area.

    PubMed

    Neuberger, J S; Hollowell, J G

    1982-11-01

    Analysis of cancer mortality in whites has revealed a significant excess in both males and females in an old lead/zinc mining and smelting area. This area consists of three rural contiguous counties: Cherokee County, Kansas, Jasper County, Missouri, and Ottawa County, Oklahoma. The lung cancer excess has persisted for at least 28 years for males and 5 years for females. A pilot case/control study is underway in Cherokee County to assess the influence of cigarette smoking, occupation, and residence on the lung cancer excess. Analysis will incorporate the histologic findings. From an environmental perspective, there are numerous mine tailings containing lead, zinc, cadmium, sulfur, germanium, and other chemicals. Considerable dust is airborne. Numerous openings (sink holes and bore holes) connect the old mines with the surface. Radium 226 has been detected in the untreated groundwater.

  14. Renewable energy for the aeration of wastewater ponds.

    PubMed

    Hobus, I; Hegemann, W

    2003-01-01

    The application of a decentralised renewable energy supply for the aeration of wastewater ponds, and the influence of an unsteady oxygen supply on the specific conversion rate and biocoenose was investigated. With the discontinuous aeration the specific conversion rate is increased as compared to facultative ponds. The estimation of the microorganisms consortia was done with in situ hybridisation techniques. A significant shift in the bacteria population with the chosen specific probes for anaerobic, sulphate reducing and nitrifying bacteria could not be detected. Wastewater ponds have sufficient buffer volume to compensate for the fluctuating energy supply. But the efficiency of the energy supply of a photovoltaic plant decreases in shallow lakes (d < 1.5 m) corresponding to a high oxygen production of algae. For the layout of the individual components: photovoltaic and wind power plant, energy management, aeration system and wastewater pond, a simulation model was developed and tested. The application of renewable energy for the aeration of wastewater ponds is a useful alternative for the redevelopment of overloaded ponds as well as the construction of new wastewater ponds, especially in areas with an inadequate central electricity grid and a high availability of wind and solar energy.

  15. High performance aerated lagoon systems

    SciTech Connect

    Rich, L.

    1999-08-01

    At a time when less money is available for wastewater treatment facilities and there is increased competition for the local tax dollar, regulatory agencies are enforcing stricter effluent limits on treatment discharges. A solution for both municipalities and industry is to use aerated lagoon systems designed to meet these limits. This monograph, prepared by a recognized expert in the field, provides methods for the rational design of a wide variety of high-performance aerated lagoon systems. Such systems range from those that can be depended upon to meet secondary treatment standards alone to those that, with the inclusion of intermittent sand filters or elements of sequenced biological reactor (SBR) technology, can also provide for nitrification and nutrient removal. Considerable emphasis is placed on the use of appropriate performance parameters, and an entire chapter is devoted to diagnosing performance failures. Contents include: principles of microbiological processes, control of algae, benthal stabilization, design for CBOD removal, design for nitrification and denitrification in suspended-growth systems, design for nitrification in attached-growth systems, phosphorus removal, diagnosing performance.

  16. Impact of post-infiltration soil aeration at different growth stages of sub-surface trickle-irrigated tomato plants

    NASA Astrophysics Data System (ADS)

    Li, Yuan; Jia, Zong-xia; Niu, Wen-Quan; Wang, Jing-wei

    2016-07-01

    Sensitivity to low rhizosphere soil aeration may change over time and therefore plant response may also depend on different growth stages of a crop. This study quantified effects of soil aeration during 5 different periods, on growth and yield of trickle-irrigated potted single tomato plants. Irrigation levels were 0.6 to 0.7 (low level) or 0.7 to 0.8 (high level) of total water holding capacity of the pots. Soil was aerated by injecting 2.5 l of air into each pot through the drip tubing immediately after irrigation. Fresh fruit yield, above ground plant dry weight, plant height, and leaf area index response to these treatments were measured. For all these 4 response variables, means of post-infiltration aeration between 58 to 85 days after sowing were 13.4, 43.5, 13.7, and 37.7% higher than those for the non-aerated pots, respectively. The results indicated that: post-infiltration soil aeration can positively impact the yield and growth of sub-surface trickle-irrigated potted tomato plants; positive effects on plant growth can be obtained with aeration during the whole growth period or with aeration for partial periods; positive growth effects of partial periods of aeration appears to persist and result in yield benefit.

  17. [Removal nitrogen of integrated vertical-flow constructed wetland under aeration condition].

    PubMed

    Tao, Min; He, Feng; Xu, Dong; Zhou, Qiao-Hong; Liang, Wei; Chen, Shui-Ping; Wu, Zhen-Bin

    2011-03-01

    Oxygen is an important limit factor of nitrogen removal in constructed wetlands, so it is the key point for improving nitrogen removal efficiency of constructed wetlands that the optimization of oxygen distribution within wetlands. Therefore, oxygen status, nitrogen removal and purification mechanism of integrated vertical-flow constructed wetland (IVCW) under aeration condition in summer and winter have been studied. The results showed that both oxygen levels and aerobic zones were increased in the wetland substrates. The area of oxic zone I (expressing with depth) extended from 22 cm, 17 cm to 53 cm, 44 cm, in summer and winter, respectively. The electric potential (Eh) profiling demonstrated that artificial aeration maintained the pattern of sequential oxic-anoxic-oxic (O-A-O) redox zones within the aerated IVCW in winter, while only two oxic-anoxic (O-A) zones were present inside the non-aerated IVCW in the cold season. The decomposition of organic matter and nitrification were obviously enhanced by artificial aeration since the removal efficiency of COD, TN and NH4(+) -N were increased by 12.2%, 6.9% and 15.1% in winter, respectively. There was no significant accumulation of NO3(-) -N in the effluent with an aeration cycle of 8 h on and 16 h off in this experiment. Moreover, we found that oxic zone I was the main region of pollutants removal in IVCW system, and artificial aeration mainly acted to enhance the purification capacity of this oxic zone in the aerated IVCW. These results suggest that aeration is important for optimization and application of IVCW system.

  18. Landfill aeration for emission control before and during landfill mining.

    PubMed

    Raga, Roberto; Cossu, Raffaello; Heerenklage, Joern; Pivato, Alberto; Ritzkowski, Marco

    2015-12-01

    The landfill of Modena, in northern Italy, is now crossed by the new high velocity railway line connecting Milan and Bologna. Waste was completely removed from a part of the landfill and a trench for the train line was built. With the aim of facilitating excavation and further disposal of the material extracted, suitable measures were defined. In order to prevent undesired emissions into the excavation area, the aerobic in situ stabilisation by means of the Airflow technology took place before and during the Landfill Mining. Specific project features involved the pneumatic leachate extraction from the aeration wells (to keep the leachate table low inside the landfill and increase the volume of waste available for air migration) and the controlled moisture addition into a limited zone, for a preliminary evaluation of the effects on process enhancement. Waste and leachate were periodically sampled in the landfill during the aeration before the excavation, for quality assessment over time; the evolution of biogas composition in the landfill body and in the extraction system for different plant set-ups during the project was monitored, with specific focus on uncontrolled migration into the excavation area. Waste biological stability significantly increased during the aeration (waste respiration index dropped to 33% of the initial value after six months). Leachate head decreased from 4 to 1.5m; leachate recirculation tests proved the beneficial effects of moisture addition on temperature control, without hampering waste aerobization. Proper management of the aeration plant enabled the minimization of uncontrolled biogas emissions into the excavation area. PMID:26445364

  19. Bedside lung ultrasound in the evaluation of acute decompensated heart failure.

    PubMed

    Leidi, Federica; Casella, Francesco; Cogliati, Chiara

    2016-06-01

    Dyspnea is a common presenting complaint in the emergency department (ED) and a leading cause of hospitalization in intensive care unit (ICU) and medical wards. Ultrasound (US) has traditionally been considered inadequate to explore the aerated lung. However, in the past 15 years LUS gained broader application, at least in part thanks to the interpretation of the artefacts generated by the interaction of US and lung structures/content. The total reflection of US beam occurring at the pleural level determines the artefactual image of the aerated lung: an homogenous 'foggy-like' picture under the pleural line. As the air content of the lungs decreases due to interstitial imbibition, deposition of collagen or presence of blood, vertical artefacts -arising from the pleural line and moving synchronously with the respiration- called B-lines appear. Multiple and bilateral B-lines identify the alveolar-interstitial syndrome (AIS). The most common cause of AIS is the wet lung: the more the congestion burden, the more the extent of the B-lines, which become confluent until the so-called white lung in case of pulmonary edema. Many studies showed a higher accuracy of LUS in diagnosing acute decompensated heart failure (ADHF) as compared to chest X-ray As recently shown, the integration of LUS to clinical assessment allow to differentiate cardiogenic dyspnea with sensitivity and specificity greater than 95 %. Moreover, LUS can easily detect pleural effusion -frequently present in ADHF-appearing as an anechoic area in the recumbent area of the thorax, delimited inferiorly by the diaphragmatic dome and superiorly by the aerated lung. PMID:26885846

  20. Feasibility Study: Home Telemonitoring for Patients With Lung Cancer in a Mountainous Rural Area

    PubMed Central

    Petitte, Trisha M.; Narsavage, Georgia L.; Chen, Yea-Jyh; Coole, Charles; Forth, Tara; Frick, Kevin D.

    2015-01-01

    Purpose/Objectives To explore the feasibility of rural home telemonitoring for patients with lung cancer. Design Exploratory, descriptive, observational. Setting Patient homes within a 75-mile radius of the study hospital in West Virginia. Sample 10 patients hospitalized with lung cancer as a primary or secondary-related diagnosis. Methods Data included referral and demographics, chart reviews, and clinical data collected using a HomMed telemonitor. Five patients received usual care after discharge; five had telemonitors set up at home for 14 days with daily phone calls for nurse coaching; mid- and end-study data were collected by phone and in homes through two months. Main Research Variables Enrollment and retention characteristics, physiologic (e.g., temperature, pulse, blood pressure, weight, O2 saturation) and 10 symptom datapoints, patient and family telemonitor satisfaction. Findings Of 45 referred patients, only 10 consented; 1 of 5 usual care and 3 of 5 monitored patients completed the entire study. Telemonitored data transmission was feasible in rural areas with high satisfaction; symptom data and physiologic data were inconsistent but characteristic of lung cancer. Conclusions Challenges included environment, culture, technology, and overall enrollment and retention. Physiologic and symptom changes were important data for nurse coaching on risks, symptom management, and clinician contact. Implications for Nursing Enrollment and retention in cancer research warrants additional study. Daily monitoring is feasible and important in risk assessment, but length of time to monitor signs and symptoms, which changed rapidly, is unclear. Symptom changes were useful as proxy indicators for physiologic changes, so risk outcomes may be assessable by phone for patient self-management coaching by nurses. PMID:24578075

  1. DESIGN INFORMATION ON FINE PORE AERATION SYSTEMS

    EPA Science Inventory

    Field studies were conducted over several years at municipal wastewater treatment plants employing line pore diffused aeration systems. These studies were designed to produce reliable information on the performance and operational requirements of fine pore devices under process ...

  2. ENHANCED BIODEGRADATION THROUGH IN-SITU AERATION

    EPA Science Inventory

    This presentation provided an overview of enhanced aerobic bioremediation using in-situ aeration or venting. The following topics were covered: (1) Basic discussion on biodegradation and respiration testing; (2) Basic discussion on volatilization, rate-limited mass transport, an...

  3. Determinants of aerosol lung-deposited surface area variation in an urban environment.

    PubMed

    Reche, Cristina; Viana, Mar; Brines, Mariola; Pérez, Noemí; Beddows, David; Alastuey, Andrés; Querol, Xavier

    2015-06-01

    Ultrafine particles are characterized by a high surface area per mass. Particle surface has been reported to play a significant role in determining the toxicological activity of ultrafine particles. In light of this potential role, the time variation of lung deposited surface area (LDSA) concentrations in the alveolar region was studied at the urban background environment of Barcelona (Spain), aiming to asses which processes and sources govern this parameter. Simultaneous data on Black Carbon (BC), total particle number (N) and particle number size distribution were correlated with LDSA. Average LDSA concentrations in Barcelona were 37 ± 26 μm(2)cm(-3), levels which seem to be characteristic for urban environments under traffic influence across Europe. Results confirm the comparability between LDSA data provided by the online monitor and those calculated based on particle size distributions (by SMPS), and reveal that LDSA concentrations are mainly influenced by particles in the size range 50-200 nm. A set of representative daily cycles for LDSA concentrations was obtained by means of a k-means cluster technique. The contribution of traffic emissions to daily patterns was evidenced in all the clusters, but was quantitatively different. Traffic events under stable atmospheric conditions increased mean hourly background LDSA concentrations up to 6 times, attaining levels higher than 200 μm(2)cm(-3). However, under warm and relatively clean atmospheric conditions, the traffic rush hour contribution to the daily LDSA mean appeared to be lower and the contribution of new urban particle formation events (by photochemically induced nucleation) was detected. These nucleation events were calculated to increase average background LDSA concentrations by 15-35% (maximum LDSA levels=45-50 μm(2)cm(-3)). Thereby, it may be concluded that in the urban background of Barcelona road traffic is the main source increasing the aerosol surface area which can deposit on critical

  4. Association between vascular-poor area of primary tumors and epidermal growth factor receptor gene status in advanced lung adenocarcinoma.

    PubMed

    Togashi, Yosuke; Masago, Katsuhiro; Kubo, Takeshi; Fujimoto, Daichi; Sakamori, Yuichi; Nagai, Hiroki; Kim, Young Hak; Togashi, Kaori; Mishima, Michiaki

    2012-12-01

    Mutation of the epidermal growth factor receptor gene (EGFR mutation) is a very important marker in the treatment for non-small cell lung cancer. Since signaling from this receptor induces tumor-associated angiogenesis, we hypothesized that lung cancers with EGFR mutations tend to develop locally with increased angiogenesis. Thus, the association between vascular-poor area of primary tumors and EGFR status was retrospectively investigated in advanced lung adenocarcinomas. To assess vascular-poor area, contrast-enhanced computed tomography scans taken before initial treatment for lung cancer were analyzed, together with primary tumor location (peripheral or central) and size. We analyzed 178 patients with advanced lung adenocarcinoma. EGFR mutations were detected in 95 of the 178 patients (53.4 %). EGFR mutation was found to be significantly related to women (P = 0.0070), never-smokers (P < 0.0001), and tumors without vascular-poor area (P < 0.0001). Based on a multivariate analysis, presence of EGFR mutations was independently associated with never-smokers (P = 0.0046), lack of vascular-poor area (P = 0.0001), and tumor size >30 mm (P = 0.0080). EGFR mutations were found in 41 of 51 never-smokers without vascular-poor area (80.4 %), 19 of 36 never-smokers with vascular-poor area (52.8 %), 19 of 37 current or former-smokers without vascular-poor area (51.4 %), and 16 of 54 current or former-smokers with vascular-poor area (29.6 %). This study showed an association between vascular-poor area of primary tumors and EGFR status. As a consequence, evaluation using a combination of smoking status and vascular-poor area allows us to predict presence of EGFR mutations at a high frequency.

  5. Oxygen transfer in circular surface aeration tanks.

    PubMed

    Rao, Achanta Ramakrishna; Patel, Ajey Kumar; Kumar, Bimlesh

    2009-06-01

    Surface aeration systems employed in activated sludge plants are the most energy-intensive units of the plants and typically account for a higher percentage of the treatment facility's total energy use. The geometry of the aeration tank imparts a major effect on the system efficiency. It is said that at optimal geometric conditions, systems exhibits the maximum efficiency. Thus the quantification of the optimal geometric conditions in surface aeration tanks is needed. Optimal geometric conditions are also needed to scale up the laboratory result to the field installation. In the present work, experimental studies have been carried out on baffled and unbaffled circular surface aeration tanks to ascertain the optimal geometric conditions. It is found that no optimal geometric conditions exist for the liquid/water depth in circular surface aeration tanks; however, for design purposes, a standard value has been assumed. Based on the optimal geometric conditions, a scale-up equation has been developed for the baffled circular surface aeration tanks.

  6. Use of the electrical aerosol detector as an indicator of the surface area of fine particles deposited in the lung.

    PubMed

    Wilson, William E; Stanek, John; Han, Hee-Siew Ryan; Johnson, Tim; Sakurai, Hiromu; Pui, David Y H; Turner, Jay; Chen, Da-Ren; Duthie, Scott

    2007-02-01

    Because of recent concerns about the health effects of ultrafine particles and the indication that particle toxicity is related to surface area, we have been examining techniques for measuring parameters related to the surface area of fine particles, especially in the 0.003- to 0.5-microm size range. In an earlier study, we suggested that the charge attached to particles, as measured by a prototype of the Electrical Aerosol Detector (EAD, TSI Inc., Model 3070), was related to the 1.16 power of the mobility diameter. An inspection of the pattern of particle deposition in the lung as a function of particle size suggested that the EAD measurement might be a useful indicator of the surface area of particles deposited in the lung. In this study, we calculate the particle surface area (micrometer squared) deposited in the lung per cubic centimeter of air inhaled as a function of particle size using atmospheric particle size distributions measured in Minneapolis, MN, and East St. Louis, IL. The correlations of powers of the mobility diameter, Dx, were highest for X = 1.1-1.6 for the deposited surface area and for X = 1.25 with the EAD signal. This overlap suggested a correspondence between the EAD signal and the deposited surface area. The correlation coefficients of the EAD signal and particle surface area deposited in the alveolar and tracheobronchial regions of the lung for three breathing patterns are in the range of Pearson's r = 0.91-0.95 (coefficient of determination, R2 = 0.82-0.90). These statistical relationships suggest that the EAD could serve as a useful indicator of particle surface area deposited in the lung in exposure and epidemiologic studies of the human health effects of atmospheric particles and as a measure of the potential surface area dose for the characterization of occupational environments.

  7. Lung cancer in never-smokers: a case-control study in a radon-prone area (Galicia, Spain).

    PubMed

    Torres-Durán, María; Ruano-Ravina, Alberto; Parente-Lamelas, Isaura; Leiro-Fernández, Virginia; Abal-Arca, José; Montero-Martínez, Carmen; Pena-Álvarez, Carolina; González-Barcala, Francisco Javier; Castro-Añón, Olalla; Golpe-Gómez, Antonio; Martínez, Cristina; Mejuto-Martí, María José; Fernández-Villar, Alberto; Barros-Dios, Juan Miguel

    2014-10-01

    The aim of the study was to assess the effect of residential radon exposure on the risk of lung cancer in never-smokers and to ascertain if environmental tobacco smoke modifies the effect of residential radon. We designed a multicentre hospital-based case-control study in a radon-prone area (Galicia, Spain). All participants were never-smokers. Cases had an anatomopathologically confirmed primary lung cancer and controls were recruited from individuals undergoing minor, non-oncological surgery. Residential radon was measured using alpha track detectors. We included 521 individuals, 192 cases and 329 controls, 21% were males. We observed an odds ratio of 2.42 (95% CI 1.45-4.06) for individuals exposed to ≥200 Bq·m(-3) compared with those exposed to <100 Bq·m(-3). Environmental tobacco smoke exposure at home increased lung cancer risk in individuals with radon exposure>200 Bq·m(-3). Individuals exposed to environmental tobacco smoke and to radon concentrations>200 Bq·m(-3) had higher lung cancer risk than those exposed to lower radon concentrations and exposed to environmental tobacco smoke. Residential radon increases lung cancer risk in never-smokers. An association between residential radon exposure and environmental tobacco smoke on the risk of lung cancer might exist.

  8. Immunohistochemical quantitation of three collagen isotypes in perfused areas and nonperfused foci of the lungs of irradiated mice

    SciTech Connect

    Miller, G.G.; Sharplin, J.; Franko, A.J. )

    1989-07-01

    Collagen isotypes I, III, and IV were quantitated by video image analysis of fluorescent-antibody-stained lung tissue sections from control and irradiated C57L/J and BALB/c mice. The perfusion status of lungs was determined by injecting colloidal carbon into the hepatic vein immediately prior to sacrificing the animals. Well-perfused parenchymal regions turned black, whereas nonperfused areas remained pale. Previous histological studies indicated substantial differences in the types of lesions found in the lungs of these two strains. C57L/J mice develop extensive and persistent contracted fibrosis. In lung sections of C57L/J mice examined 28 weeks after a dose of 11 Gy X rays, all three collagen isotypes were significantly elevated to levels 37-51% higher than age-matched control values in perfused regions of lung. In nonperfused areas, which had the histological appearance of contracted scar tissue, the three collagen isotype levels were further elevated to values 83-90% greater than controls. This finding suggests that in C57L/J mice, an elevation of each or all of the three collagen isotypes to levels approximately 45% greater than controls is consistent with continued pulmonary function during the intermediate phase of lung damage, whereas areas of parenchyma containing isotype levels in excess of 185% of control values coincide with functionally deficient regions. BALB/cCr Alt. mice examined 28 weeks subsequent to 14.5 Gy X rays had a variety of visible lesion, most of which were nonperfused. In addition, one-quarter of nonperfused acini had no visible lesion. In perfused areas, the three isotypes were increased to 119-132% of control levels, with a further, significant (P less than 0.05) increase to 128-144% of control values in nonperfused parenchyma.

  9. Nucleotide excision repair genes and risk of lung cancer among San Francisco bay area Latinos and African Americans

    PubMed Central

    Chang, Jeffrey S.; Wrensch, Margaret R.; Hansen, Helen M.; Sison, Jennette D.; Aldrich, Melinda C.; Quesenberry, Charles P.; Seldin, Michael F.; Kelsey, Karl T.; Kittles, Rick A.; Silva, Gabriel; Wiencke, John K.

    2009-01-01

    Few studies on the association between nucleotide excision repair (NER) variants and lung cancer risk have included Latinos and African Americans. We examine variants in six NER genes (ERCC2, ERCC4, ERCC5, LIG1, RAD23B and XPC) in association with primary lung cancer risk among 113 Latino and 255 African American subjects newly diagnosed with primary lung cancer from 1998 to 2003 in the San Francisco Bay Area, and 579 healthy controls (299 Latinos and 280 African Americans). Individual single nucleotide polymorphism and haplotype analyses, multifactor dimensionality reduction, and principal components analysis were performed to assess the association between six genes in the NER pathway and lung cancer risk. Among Latinos, ERCC2 haplotype CGA (rs238406, rs11878644, rs6966) was associated with reduced lung cancer risk [odds ratio (OR) of 0.65 and 95% confidence interval (CI): 0.44-0.97], especially among non-smokers (OR=0.29; 95% CI: 0.12-0.67). From multifactor dimensionality reduction analysis, in Latinos, smoking and three SNPs (ERCC2 rs171140, ERCC5 rs17655, and LIG1 rs20581) together had a prediction accuracy of 67.4% (p=0.001) for lung cancer. Among African Americans, His/His genotype of ERCC5 His1104Asp (rs17655) was associated with increased lung cancer risk (OR=1.78; 95% CI: 1.09-2.91), and LIG1 haplotype GGGAA (rs20581, rs156641, rs3730931, rs20579, and rs439132) was associated with reduced lung cancer risk (OR=0.61; 95% CI: 0.42-0.88). Our study suggests different elements of the NER pathway may be important in the different ethnic groups resulting either from different linkage relationship, genetic backgrounds, and/or exposure histories. PMID:18709642

  10. [{sup 18}F]fluorodeoxyglucose Uptake Patterns in Lung Before Radiotherapy Identify Areas More Susceptible to Radiation-Induced Lung Toxicity in Non-Small-Cell Lung Cancer Patients

    SciTech Connect

    Petit, Steven F.; Elmpt, Wouter J.C. van; Oberije, Cary J.G.; Vegt, Erik; Dingemans, Anne-Marie C.; Lambin, Philippe; Dekker, Andre L.A.J.; De Ruysscher, Dirk

    2011-11-01

    received more than 2 Gy to 5 Gy increased. Therefore, the risk of RILT may be decreased by applying sophisticated radiotherapy techniques to avoid areas in the lung with high [{sup 18}F]FDG uptake.

  11. Acid mine water aeration and treatment system

    DOEpatents

    Ackman, Terry E.; Place, John M.

    1987-01-01

    An in-line system is provided for treating acid mine drainage which basically comprises the combination of a jet pump (or pumps) and a static mixer. The jet pump entrains air into the acid waste water using a Venturi effect so as to provide aeration of the waste water while further aeration is provided by the helical vanes of the static mixer. A neutralizing agent is injected into the suction chamber of the jet pump and the static mixer is formed by plural sections offset by 90 degrees.

  12. Lung Cancer Attributable to Indoor Radon Exposures in Two Radon—Prone Areas, Ştei (Romania) and Torrelodones (Spain)

    NASA Astrophysics Data System (ADS)

    Dinu, Alexandra; Cosma, Constantin; Sainz, Carlos; Poncela, Luis Santiago Quindós; Vasiliniuc, Ştefan

    2009-05-01

    Radon and radon progeny are present indoors, in houses and others dwellings, representing the most important contribution to dose from natural sources of radiation. Most studies have demonstrated an increased risk of lung cancer at high concentration of radon for both smokers and nonsmokers. For medium and low concentrations which are the typical residential radon levels, recent researches have also demonstrated increased risks of lung cancer for people exposed. The work presents a comparative analysis of the radon exposure data in the two radon—prone areas, Ştei, Transylvania, (Romania), in the near of old Romanian uranium mines and in the granitic area of Torrelodones town, Sierra de Guadarrama (Spain). One important difference between the two studied areas is related to the houses built using uranium waste as construction material in Ştei area. Measurements of indoor radon were performed in 280 dwellings (Romania) and 91 dwellings (Spain) by using nuclear track detectors, CR 39. The highest value measured in Ştei area was 2650 Bqṡm-3. and 366 Bqṡm-3 in the Spanish region. The results are compute with the BEIR VI report estimates using the age-duration model at an exposure rate below 2650 Bqṡm-3. A total of 233 lung cancer deaths were calculated in the Ştei area for a period of 13 years (1994-2006), which is 116.82% higher than observed from the national statistics. In comparison, in Torrelodones area, a number of 276 deaths caused by lung cancer were estimated along a period of 13 years, which is 2.09 times higher than the number observed by authorities. This represents a significantly evidence that elevated risk can strongly be associated with cumulated radon exposure.

  13. Lung Cancer Attributable to Indoor Radon Exposures in Two Radon--Prone Areas, Stei (Romania) and Torrelodones (Spain)

    SciTech Connect

    Dinu, Alexandra; Cosma, Constantin; Vasiliniuc, Stefan; Sainz, Carlos; Poncela, Luis Santiago Quindos

    2009-05-22

    Radon and radon progeny are present indoors, in houses and others dwellings, representing the most important contribution to dose from natural sources of radiation. Most studies have demonstrated an increased risk of lung cancer at high concentration of radon for both smokers and nonsmokers. For medium and low concentrations which are the typical residential radon levels, recent researches have also demonstrated increased risks of lung cancer for people exposed. The work presents a comparative analysis of the radon exposure data in the two radon--prone areas, Stei, Transylvania, (Romania), in the near of old Romanian uranium mines and in the granitic area of Torrelodones town, Sierra de Guadarrama (Spain). One important difference between the two studied areas is related to the houses built using uranium waste as construction material in Stei area. Measurements of indoor radon were performed in 280 dwellings (Romania) and 91 dwellings (Spain) by using nuclear track detectors, CR 39. The highest value measured in Stei area was 2650 Bq{center_dot}m{sup -3}. and 366 Bq{center_dot}m{sup -3} in the Spanish region. The results are compute with the BEIR VI report estimates using the age-duration model at an exposure rate below 2650 Bq{center_dot}m{sup -3}. A total of 233 lung cancer deaths were calculated in the Stei area for a period of 13 years (1994-2006), which is 116.82% higher than observed from the national statistics. In comparison, in Torrelodones area, a number of 276 deaths caused by lung cancer were estimated along a period of 13 years, which is 2.09 times higher than the number observed by authorities. This represents a significantly evidence that elevated risk can strongly be associated with cumulated radon exposure.

  14. Surfactant effects on alpha-factors in aeration systems.

    PubMed

    Rosso, Diego; Stenstrom, Michael K

    2006-04-01

    Aeration in wastewater treatment processes accounts for the largest fraction of plant energy costs. Aeration systems function by shearing the surface (surface aerators) or releasing bubbles at the bottom of the tank (coarse- or fine-bubble aerators). Surfactant accumulation on gas-liquid interfaces reduces mass transfer rates, and this reduction in general is larger for fine-bubble aerators. This study evaluates mass transfer effects on the characterization and specification of aeration systems in clean and process water conditions. Tests at different interfacial turbulence regimes show higher gas transfer depression for lower turbulence regimes. Contamination effects can be offset at the expense of operating efficiency, which is characteristic of surface aerators and coarse-bubble diffusers. Results describe the variability of alpha-factors measured at small scale, due to uncontrolled energy density. Results are also reported in dimensionless empirical correlations describing mass transfer as a function of physiochemical and geometrical characteristics of the aeration process. PMID:16549087

  15. 3-D Numerical Simulation for Gas-Liquid Two-Phase Flow in Aeration Tank

    NASA Astrophysics Data System (ADS)

    Xue, R.; Tian, R.; Yan, S. Y.; Li, S.

    In the crafts of activated sludge treatment, oxygen supply and the suspending state of activated sludge are primary factors to keep biochemistry process carrying on normally. However, they are all controlled by aeration. So aeration is crucial. The paper focus on aeration, use CFD software to simulate the field of aeration tank which is designed by sludge load method. The main designed size of aeration tank is: total volume: 20 000 m3; corridor width: 8m; total length of corridors: 139m; number of corridors: 3; length of one single corridor: 48m; effective depth: 4.5m; additional depth: 0.5m. According to the similarity theory, a geometrical model is set up in proportion of 10:1. The way of liquid flow is submerge to avoid liquid flow out directly. The grid is plotted by dividing the whole computational area into two parts. The bottom part which contains gas pipe and gas exit hole and the above part which is the main area are plotted by tetrahedron and hexahedron respectively. In boundary conditions, gas is defined as the primary-phase, and liquid is defined as the secondary-phase. Choosing mixture model, two-phase flow field of aeration tank is simulated by solved the Continuity equation for the mixture, Momentum equation for the mixture, Volume fraction equation for the secondary phases and Relative velocity formula when gas velocity is 10m/s, 20m/s, 30m/s. what figure shows is the contour of velocity magnitude for the mixture phase when gas velocity is 20m/s. Through analysis, the simulation tendency is agreed with actual running of aeration tank. It is feasible to use mixture model to simulate flow field of aeration tank by fluent software. According to the simulation result, the better velocity of liquid or gas (the quantity of inlet air) can be chosen by lower cost, and also the performance of aeration tank can be forecast. It will be helpful for designing and operation.

  16. Differences in lung cancer mortality trends from 1986-2012 by radon risk areas in British Columbia, Canada.

    PubMed

    Henderson, Sarah B; Rauch, Stephen A; Hystad, Perry; Kosatsky, Tom

    2014-05-01

    Residential exposure to radon gas is associated with increased risk of lung cancer, especially in smokers. Most evidence about the health effects of radon has been derived from meta-analyses on global epidemiologic studies, but administrative data can help public health authorities to explore the local impacts. Eighty health units in British Columbia (BC), Canada, were classified as having low, moderate, or high radon risk using more than 3,800 residential measurements. Vital statistics records were used to identify deaths due to lung cancer and to all natural causes. The annual ratio of lung cancer mortality to all natural mortality was plotted for the 1986-2012 study period for each radon classification. Visualizations were stratified by gender and by smoking prevalence. The overall ratio increased throughout the study period in high radon areas and remained stable in low and moderate radon areas. The increase was most pronounced for females, especially when plots were stratified by smoking prevalence. These limited but interesting findings confirm that radon is one risk factor for lung cancer mortality in BC and that its effects differ across gender and smoking strata. The results would be strengthened by replication, and more rigorous methods are required to assess other contributing factors.

  17. Lifetime risk of urothelial carcinoma and lung cancer in the arseniasis-endemic area of Northeastern Taiwan

    NASA Astrophysics Data System (ADS)

    Yang, Tse-Yen; Hsu, Ling-I.; Chen, Hui-Chi; Chiou, Hung-Yi; Hsueh, Yu-Mei; Wu, Meei-Maan; Chen, Chi-Ling; Wang, Yuan-Hung; Liao, Ya-Tang; Chen, Chien-Jen

    2013-11-01

    Arsenic in drinking water has been shown to increase the risk of urothelial carcinoma and lung cancer. However, the lifetime risk of developing urothelial carcinoma and lung cancer caused by exposure to arsenic in drinking water has not been reported. This study aimed to assess the lifetime risk of urothelial carcinoma and lung cancer caused by arsenic exposure from drinking water and cigarette smoking habit for residents living in the arseniasis-endemic area in Northeastern Taiwan. We recruited 8086 residents in 1991-1994 and monitored them for their newly developed types of cancers, identified by computerized linkage with the national cancer registry profile. There were 37 newly diagnosed urothelial carcinoma cases and 223 new lung cancer cases during the follow-up period (until 2007). The lifetime (35-85 years old) cumulative risk of developing urothelial carcinoma from an arsenic concentration in the drinking water of <10, 10-99, and 100+ μg/L was 0.29%, 1.07% and 3.43%, respectively. The corresponding probabilities were 7.42%, 8.99% and 17.09% for the lifetime risk of developing lung cancer. Cigarette smoking was associated with an increased risk of urothelial carcinoma and lung cancer, showing the hazard ratio (95% confidence interval) of 2.48 (1.27-4.82) and 3.44 (2.00-5.90) after adjusting for the arsenic concentration in drinking water. After adjusting for cigarette smoking, the hazard ratio (95% confidence interval) of developing urothelial carcinoma caused by the arsenic concentration in drinking water of <10, 10-99 and 100+ μg/L was 1.0 (the reference group), 2.18 (0.59-8.01), and 8.71 (2.49-30.48), respectively. The corresponding figures were 1.0 (the reference group), 1.14 (0.80-1.61), 1.84 (1.28-2.65) for lung cancer. Synergistic effects on the development of urothelial carcinoma and lung cancer existed between the arsenic exposure level and cigarette smoking. It is suggested that people who have had a high exposure to arsenic in drinking water

  18. Performance of a fixed-bed biofilm reactor with microbubble aeration in aerobic wastewater treatment.

    PubMed

    Zhang, Lei; Liu, Junliang; Liu, Chun; Zhang, Jing; Yang, Jingliang

    2016-01-01

    Microbubble aeration is supposed to be highly efficient for oxygen supply in aerobic wastewater treatment. In the present study, the performance of a fixed-bed biofilm reactor microbubble-aerated using a Shirasu porous glass (SPG) membrane system was investigated when treating synthetic municipal wastewater. The biofilm formation on the carriers was enhanced with microbubble aeration due to the strong adhesion of microbubbles to the solid surface. The dissolved oxygen concentration, the removals of chemical oxygen demand (COD) and nitrogen, and the oxygen utilization efficiency were influenced by the organic loading rate at a certain oxygen supply capacity. The relatively optimal organic loading rate was determined as 0.82 kgCOD/(m(3)d) when the oxygen supply capacity was 0.93 kgO(2)/(m(3)d), where COD and ammonia removal efficiencies were 91.7% and 53.9%, respectively. The corresponding SPG membrane area-based COD removal capacity was 6.88 kgCOD/(m(2)d). The oxygen utilization efficiency of microbubble aeration was obviously higher compared to conventional bubble aeration. The simultaneous nitrification and denitrification occurred in the biofilm reactor and the total nitrogen removal efficiency of 50.4% was achieved under these conditions. In addition, the increase in air supply capacity of the SPG membrane system was suggested to improve its energy utilization efficiency. PMID:27386991

  19. Evaluation of oxygen transfer parameters of fine-bubble aeration system in plug flow aeration tank of wastewater treatment plant.

    PubMed

    Zhou, Xiaohong; Wu, Yuanyuan; Shi, Hanchang; Song, Yanqing

    2013-02-01

    Knowledge of the oxygen mass transfer of aerators under operational conditions in a full-scale wastewater treatment plant (WWTP) is meaningful for the optimization of WWTP, however, scarce to best of our knowledge. Through analyzing a plug flow aeration tank in the Lucun WWTP, in Wuxi, China, the oxygenation capacity of fine-bubble aerators under process conditions have been measured in-situ using the off-gas method and the non-steady-state method. The off-gas method demonstrated that the aerators in different corridors in the aeration tank of WWTP ha d significantly different oxygen transferperformance; furthermore, the aerators in the samecorridor shared almost equal oxygen transfer performance over the course of a day. Results measured by the two methods showed that the oxygen transfer performance of fine-bubble aerators in the aeration tank decreased dramatically compared with that in the clean water. The loss of oxygen transfer coefficient was over 50% under low-aeration conditions (aeration amount < 0.67 Nm3/hr). However, as the aeration amount reached 0.96 Nm3/hr, the discrepancy of oxygen transfer between the process condition and clean water was negligible. The analysis also indicated that the non-steady-state and off-gas methods resulted in comparable estimates of oxygen transfer parameters for the aerators under process conditions.

  20. Dietary exposure estimates of 14 trace elements in Xuanwei and Fuyuan, two high lung cancer incidence areas in China.

    PubMed

    Zhang, Linlin; Lv, Jungang; Liao, Chunyang

    2012-06-01

    Xuanwei and Fuyuan, located in the Yunnan province in southwest of China, are known to have a strikingly high incidence of lung cancer. Among the many factors that have been explored, the association between lung cancer and trace elements has not received enough attention. In this study, dietary samples were collected from 60 families of the lung cancer and control groups and abundances of 14 trace elements were determined using inductively coupled-plasma mass spectroscopy. Accuracy and sensitivity of the method were demonstrated by analyzing national standard reference materials. The results showed that the dietary intake of the trace elements contributed 96.6% of total intake. Among the 14 elements tested, cadmium and titanium were found to be present at a significantly higher level in the food consumed by the cancer group than by the control group. The intake of selenium by the population living in the areas is much lower than what it should be, with the people in the cancer group experiencing even more severe selenium deficiency. In addition, in both groups, the intakes of several essential elements (iron, copper, and zinc) from food and the drinking water were found to be significantly lower than required according to the Chinese Dietary Reference Intakes. The present study of the relationship between trace element intakes of lung cancer cases and controls provides important information urgently needed for the assessment of lung cancer risk of healthy subjects. The study also gives rational dietary suggestions to local residents which is important to the early diagnosis and pretreatment of lung cancer. PMID:22068732

  1. Automated segmentation of lung airway wall area measurements from bronchoscopic optical coherence tomography imaging

    NASA Astrophysics Data System (ADS)

    Heydarian, Mohammadreza; Choy, Stephen; Wheatley, Andrew; McCormack, David; Coxson, Harvey O.; Lam, Stephen; Parraga, Grace

    2011-03-01

    Chronic Obstructive Pulmonary Disease (COPD) affects almost 600 million people and is currently the fourth leading cause of death worldwide. COPD is an umbrella term for respiratory symptoms that accompany destruction of the lung parenchyma and/or remodeling of the airway wall, the sum of which result in decreased expiratory flow, dyspnea and gas trapping. Currently, x-ray computed tomography (CT) is the main clinical method used for COPD imaging, providing excellent spatial resolution for quantitative tissue measurements although dose limitations and the fundamental spatial resolution of CT limit the measurement of airway dimensions beyond the 5th generation. To address this limitation, we are piloting the use of bronchoscopic Optical Coherence Tomography (OCT), by exploiting its superior spatial resolution of 5-15 micrometers for in vivo airway imaging. Currently, only manual segmentation of OCT airway lumen and wall have been reported but manual methods are time consuming and prone to observer variability. To expand the utility of bronchoscopic OCT, automatic and robust measurement methods are required. Therefore, our objective was to develop a fully automated method for segmenting OCT airway wall dimensions and here we explore several different methods of image-regeneration, voxel clustering and post-processing. Our resultant automated method used K-means or Fuzzy c-means to cluster pixel intensity and then a series of algorithms (i.e. cluster selection, artifact removal, de-noising) was applied to process the clustering results and segment airway wall dimensions. This approach provides a way to automatically and rapidly segment and reproducibly measure airway lumen and wall area.

  2. Changes in breath sound power spectra during experimental oleic acid-induced lung injury in pigs.

    PubMed

    Räsänen, Jukka; Nemergut, Michael E; Gavriely, Noam

    2014-01-01

    To evaluate the effect of acute lung injury on the frequency spectra of breath sounds, we made serial acoustic recordings from nondependent, midlung and dependent regions of both lungs in ten 35- to 45-kg anesthetized, intubated, and mechanically ventilated pigs during development of acute lung injury induced with intravenous oleic acid in prone or supine position. Oleic acid injections rapidly produced severe derangements in the gas exchange and mechanical properties of the lung, with an average increase in venous admixture from 16 ± 12 to 62 ± 16% (P < 0.01), and a reduction in dynamic respiratory system compliance from 25 ± 4 to 14 ± 4 ml/cmH2O (P < 0.01). A concomitant increase in sound power was seen in all lung regions (P < 0.05), predominantly in frequencies 150-800 Hz. The deterioration in gas exchange and lung mechanics correlated best with concurrent spectral changes in the nondependent lung regions. Acute lung injury increases the power of breath sounds likely secondary to redistribution of ventilation from collapsed to aerated parts of the lung and improved sound transmission in dependent, consolidated areas.

  3. Investigation of radon and heavy metals in Xuanwei and Fuyuan, high lung cancer incidence areas in China.

    PubMed

    Lv, Jungang; Zhang, Wen; Xu, Renji

    2013-11-01

    Xuanwei and Fuyuan, two counties located in southwest China, are areas with known high lung cancer incidence. Pollution relative to coal combustion, especially serious air pollution generated by burning smoky coals in unvented households, has been thought to be the most predominant cause. Possible inorganic carcinogenic matter including radon in air and arsenic, lead, chromium, cadmium, nickel, and beryllium in water, soil, and coal were sampled and examined to find the current pollution status, distributions, characteristics, and relationships to the lung cancer incidence. The concentrations of mercury in air of Xuanwei and Fuyuan ranged from 1.7 to 205.3 ng/m3 (indoor), 1.3 to 7.5 ng/m3 (ambient). No radon concentration exceeded the World Health Organization standard. Results indicated that household stove improvement by changing stoves from unvented to vented obviously alleviated the indoor air pollution of carcinogenic metals. Most of the carcinogenic metals were also found at very low levels in water and soil, which therefore had little influence on human health. Concentrations of these elements at different sites did not vary in any relation to lung cancer incidence. The study described in this article added basic data; the results of the authors' study will be helpful in determining pollution status and to future studies on the etiology of lung cancer.

  4. CFD model of an aerating hydrofoil

    NASA Astrophysics Data System (ADS)

    Scott, D.; Sabourin, M.; Beaulieu, S.; Papillon, B.; Ellis, C.

    2014-03-01

    Improving water quality in the tailrace below hydroelectric dams has become a priority in many river systems. In warm climates, water drawn by the turbine from deep in a reservoir can be deficient in dissolved oxygen (DO), a critical element in maintaining a healthy aquatic ecosystem. Many different solutions have been proposed in order to increase the DO levels in turbine discharge, including: turbine aeration systems (adding air to the water through either the turbine hub, the periphery or through distributed aeration in the runner blades); bubble diffusers in the reservoir or in the tailrace; aerating weirs downstream of the dams; and surface water pumps in the reservoir near the dam. There is a significant potential to increase the effectiveness of these solutions by improving the way that oxygen is introduced into the water; better distributions of bubbles will result in better oxygen transfer. In the present study, a two-phase Computational Fluid Dynamics model has been formulated using a commercial code to study the distribution of air downstream of a simple aerating hydrofoil. The two-phase model uses the Eulerian-Eulerian approach. Appropriate relations are used to model the interphase forces, including the Grace drag force model, the Favre averaged drag force and the Sato enhanced eddy viscosity. The model is validated using experimental results obtained in the water tunnel at the University of Minnesota's Saint Anthony Falls Laboratory. Results are obtained for water velocities between 5 and 10 m/s, air flow rates between 0.5 and 1.5 sL/min and for angles of attack between 0° and -8°. The results of this study show that the CFD model provides a good qualitative comparison to the experimental results by well predicting the wake location at the different flow rates and angles of attack used.

  5. Environmental Carcinogen Releases and Lung Cancer Mortality in Rural-Urban Areas of the United States

    ERIC Educational Resources Information Center

    Luo, Juhua; Hendryx, Michael

    2011-01-01

    Purpose: Environmental hazards are unevenly distributed across communities and populations; however, little is known about the distribution of environmental carcinogenic pollutants and lung cancer risk across populations defined by race, sex, and rural-urban setting. Methods: We used the Toxics Release Inventory (TRI) database to conduct an…

  6. Effects of aeration method and aeration rate on greenhouse gas emissions during composting of pig feces in pilot scale.

    PubMed

    Jiang, Tao; Li, Guoxue; Tang, Qiong; Ma, Xuguang; Wang, Gang; Schuchardt, Frank

    2015-05-01

    The aim of this study was to uncover ways to mitigate greenhouse gas (GHG) emissions and reduce energy consumption during the composting process. We assessed the effects of different aeration rates (0, 0.18, 0.36, and 0.54 L/(kg dry matter (dm)·min)) and methods (continuous and intermittent) on GHG emissions. Pig feces and corn stalks were mixed at a ratio of 7:1. The composting process lasted for 10 weeks, and the compost was turned approximately every 2 weeks. Results showed that both aeration rate and method significantly affected GHG emissions. Higher aeration rates increased NH3 and N2O losses, but reduced CH4 emissions. The exception is that the CH4 emission of the passive aeration treatment was lower than that of the low aeration rate treatment. Without forced aeration, the CH4 diffusion rates in the center of the piles were very low and part of the CH4 was oxidized in the surface layer. Intermittent aeration reduced NH3 and CH4 losses, but significantly increased N2O production during the maturing periods. Intermittent aeration increased the nitrification/denitrification alternation and thus enhanced the N2O production. Forced aeration treatments had higher GHG emission rates than the passive aeration treatment. Forced aeration accelerated the maturing process, but could not improve the quality of the end product. Compared with continuous aeration, intermittent aeration could increase the O2 supply efficiency and reduced the total GHG emission by 17.8%, and this reduction increased to 47.4% when composting was ended after 36 days. PMID:25968266

  7. Effects of aeration method and aeration rate on greenhouse gas emissions during composting of pig feces in pilot scale.

    PubMed

    Jiang, Tao; Li, Guoxue; Tang, Qiong; Ma, Xuguang; Wang, Gang; Schuchardt, Frank

    2015-05-01

    The aim of this study was to uncover ways to mitigate greenhouse gas (GHG) emissions and reduce energy consumption during the composting process. We assessed the effects of different aeration rates (0, 0.18, 0.36, and 0.54 L/(kg dry matter (dm)·min)) and methods (continuous and intermittent) on GHG emissions. Pig feces and corn stalks were mixed at a ratio of 7:1. The composting process lasted for 10 weeks, and the compost was turned approximately every 2 weeks. Results showed that both aeration rate and method significantly affected GHG emissions. Higher aeration rates increased NH3 and N2O losses, but reduced CH4 emissions. The exception is that the CH4 emission of the passive aeration treatment was lower than that of the low aeration rate treatment. Without forced aeration, the CH4 diffusion rates in the center of the piles were very low and part of the CH4 was oxidized in the surface layer. Intermittent aeration reduced NH3 and CH4 losses, but significantly increased N2O production during the maturing periods. Intermittent aeration increased the nitrification/denitrification alternation and thus enhanced the N2O production. Forced aeration treatments had higher GHG emission rates than the passive aeration treatment. Forced aeration accelerated the maturing process, but could not improve the quality of the end product. Compared with continuous aeration, intermittent aeration could increase the O2 supply efficiency and reduced the total GHG emission by 17.8%, and this reduction increased to 47.4% when composting was ended after 36 days.

  8. A retrospective study on malignant neoplasms of bladder, lung and liver in blackfoot disease endemic area in Taiwan.

    PubMed

    Chen, C J; Chuang, Y C; You, S L; Lin, T M; Wu, H Y

    1986-03-01

    A total of 69 bladder cancer, 76 lung cancer and 59 liver cancer deceased cases and 368 alive community controls group-matched on age and sex were studied to evaluate the association between high-arsenic artesian well water and cancers in the endemic area of blackfoot disease (BFD), a unique peripheral vascular disease related to continuous arsenic exposure. According to a standardized structured questionnaire, information on risk factors was obtained through proxy interview of the cases and personal interview of the controls. A positive dose-response relationship was observed between the exposure to artesian well water and cancers of bladder, lung and liver. The age-sex-adjusted odds ratios of developing bladder, lung and liver cancers for those who had used artesian well water for 40 or more years were 3.90, 3.39, and 2.67, respectively, as compared with those who never used artesian well water. Multiple binary logistic regression analyses showed that the dose-response relationships and odds ratios remained much the same while other risk factors were further adjusted.

  9. Small area mapping of domestic radon, smoking prevalence and lung cancer incidence--A case study in Northamptonshire, UK.

    PubMed

    Denman, Antony R; Rogers, Stephen; Ali, Akeem; Sinclair, John; Phillips, Paul S; Crockett, Robin G M; Groves-Kirkby, Christopher J

    2015-12-01

    Smoking and radon both cause lung cancer, and together the risk is significantly higher. UK public health campaigns continue to reduce smoking prevalence, and other initiatives identify houses with raised radon (radon-222) levels and encourage remedial action. Smoking prevalence and radon levels in the UK have been mapped at Primary Care Trust level. This paper extends that work, using a commercial socio-demographic database to estimate smoking prevalence at the postcode sector level, and to predict the population characteristics at postcode sector level for 87 postcode sectors in Northamptonshire. Likely smoking prevalence in each postcode sector is then modelled from estimates of the smoking prevalence in the different socio-economic groups used by the database. Mapping estimated smoking prevalence, radon potential and average lung cancer incidence for each postcode sector suggested that there was little correlation between smoking prevalence and radon levels, as radon potential was generally lower in urban areas in Northamptonshire, where the estimates of smoking prevalence were highest. However, the analysis demonstrated some sectors where both radon potential and smoking prevalence were moderately raised. This study showed the potential of this methodology to map estimated smoking prevalence and radon levels to inform locally targeted public health campaigns to reduce lung cancer incidence.

  10. Small area mapping of domestic radon, smoking prevalence and lung cancer incidence--A case study in Northamptonshire, UK.

    PubMed

    Denman, Antony R; Rogers, Stephen; Ali, Akeem; Sinclair, John; Phillips, Paul S; Crockett, Robin G M; Groves-Kirkby, Christopher J

    2015-12-01

    Smoking and radon both cause lung cancer, and together the risk is significantly higher. UK public health campaigns continue to reduce smoking prevalence, and other initiatives identify houses with raised radon (radon-222) levels and encourage remedial action. Smoking prevalence and radon levels in the UK have been mapped at Primary Care Trust level. This paper extends that work, using a commercial socio-demographic database to estimate smoking prevalence at the postcode sector level, and to predict the population characteristics at postcode sector level for 87 postcode sectors in Northamptonshire. Likely smoking prevalence in each postcode sector is then modelled from estimates of the smoking prevalence in the different socio-economic groups used by the database. Mapping estimated smoking prevalence, radon potential and average lung cancer incidence for each postcode sector suggested that there was little correlation between smoking prevalence and radon levels, as radon potential was generally lower in urban areas in Northamptonshire, where the estimates of smoking prevalence were highest. However, the analysis demonstrated some sectors where both radon potential and smoking prevalence were moderately raised. This study showed the potential of this methodology to map estimated smoking prevalence and radon levels to inform locally targeted public health campaigns to reduce lung cancer incidence. PMID:26334595

  11. Cancer of the lung, pleura, larynx and pharynx in an area with an asbestos-cement plant.

    PubMed

    Curin, K; Sarić, M

    1995-09-01

    Data on persons who died of cancer of the respiratory tract and pharynx in a Croatian coastal area with an asbestos-cement industry were collected and analysed for the period 1970-1990. Cancer mortality data were obtained from the Cancer Registry of Croatia. By the poll method, additional data on occupation, life style (smoking, alcohol drinking), length of residence in the area, educational level and cancer mortality among the relatives were obtained. The results of the investigation showed that the mortality rates for the lung, larynx and pharynx cancers, standardized according to age, were lower in the study area than expected (data for Croatia). Standardized mortality rates for mesothelioma were higher in the area under study for both sexes (except for women in the rural part of the area) than in Croatia. Within the study area the highest mortality rates for follow-up cancers were registered in the settlement where the asbestos-cement plant was located. Some settlements in two municipalities within the area also had higher mortality rates caused by these tumours in comparison with the rest of the study area or Croatia as a whole. In the evaluation of the obtained findings possible uneven distribution of emissions from the asbestos-cement plant caused by prevailing wind and air stream direction were considered.

  12. Association between lung function in school children and exposure to three transition metals from an e-waste recycling area.

    PubMed

    Zheng, Guina; Xu, Xijin; Li, Bin; Wu, Kusheng; Yekeen, Taofeek Akangbe; Huo, Xia

    2013-01-01

    The informal processing of electronic waste or e-waste contributes to the release of high concentrations of transition metals into the ambient air. The damage caused by chromium, nickel and manganese exposure on lung function in school children from an e-waste recycling area and the role of oxidative stress in this process were evaluated. We recruited school children (n=144, 8-13 years) from an e-waste recycling area in China compared with the control. Spirometry was performed to assess lung function status. The blood levels of chromium, nickel and manganese, antioxidant enzyme activities and lipid peroxidation of the subjects were examined. The concentrations of blood manganese (bMn) and serum nickel (sNi) in the exposed group were significantly higher than those in controls for all three age groups. The forced vital capacity value of boys aged 8-9 years was significantly lower than that of the control. Malondialdehyde levels and superoxide dismutase activities increased significantly in children aged 8-9 years from e-waste environment, but catalase activities declined. School children from an e-waste recycling area were exposed to high levels of the three transition metals. The accumulation of bMn and sNi may be risk factors for oxidative damage and decreased pulmonary function. PMID:22854517

  13. Municipal sludge characteristic changes under different aerating condition in a deep-shaft aeration system.

    PubMed

    Xiong, Jiaqing; Wang, Xiaochang C; Shu, Wei; He, Teng; Liu, Yanzheng

    2016-01-01

    A pilot-scale municipal sewage sludge deep-shaft aeration system was implemented in Lanzhou, Gansu Province of China. The reactor depth was 60 m with a diameter of 1.0 m and the sludge to be treated came from a wastewater plant in Lanzhou. In order to obtain the optimum operation conditions, analysis was conducted on the transformations of the volatile suspended solids (VSS), temperature, pH, oxidation-reduction potential (ORP) and pathogens in the deep-shaft reactor under different aeration conditions. Attention was paid to how operating conditions affected the removal efficiency of the VSS and the reaction temperature. As a result, higher volatile solids removal was gained at higher temperature, and the temperature could reach 50.8°C for a complete inactivation of bacteria in the first reaction zone when the deep-shaft aeration system was run for about 18 days. The sludge aeration rate was observed as 1.5 to 1.8 L/(h·L sludge) which enabled the volatile solids removal rate to reach 40.1%. The degradation of VSS occurred under a micro-oxygen environment, and the lowest ORP was found to be -256 mV in the digestive process. Not only aerobic bacteria but also anaerobic and facultative bacteria performed their functions in the reactor.

  14. Municipal sludge characteristic changes under different aerating condition in a deep-shaft aeration system.

    PubMed

    Xiong, Jiaqing; Wang, Xiaochang C; Shu, Wei; He, Teng; Liu, Yanzheng

    2016-01-01

    A pilot-scale municipal sewage sludge deep-shaft aeration system was implemented in Lanzhou, Gansu Province of China. The reactor depth was 60 m with a diameter of 1.0 m and the sludge to be treated came from a wastewater plant in Lanzhou. In order to obtain the optimum operation conditions, analysis was conducted on the transformations of the volatile suspended solids (VSS), temperature, pH, oxidation-reduction potential (ORP) and pathogens in the deep-shaft reactor under different aeration conditions. Attention was paid to how operating conditions affected the removal efficiency of the VSS and the reaction temperature. As a result, higher volatile solids removal was gained at higher temperature, and the temperature could reach 50.8°C for a complete inactivation of bacteria in the first reaction zone when the deep-shaft aeration system was run for about 18 days. The sludge aeration rate was observed as 1.5 to 1.8 L/(h·L sludge) which enabled the volatile solids removal rate to reach 40.1%. The degradation of VSS occurred under a micro-oxygen environment, and the lowest ORP was found to be -256 mV in the digestive process. Not only aerobic bacteria but also anaerobic and facultative bacteria performed their functions in the reactor. PMID:27054720

  15. Aeration control of thermophilic aerobic digestion using fluorescence monitoring.

    PubMed

    Kim, Young-Kee; Oh, Byung-Keun

    2009-01-01

    The thermophilic aerobic digestion (TAD) process is recognized as an effective method for rapid waste activated sludge (WAS) degradation and the deactivation of pathogenic microorganisms. Yet, high energy costs due to heating and aeration have limited the commercialization of economical TAD processes. Previous research on autothermal thermophilic aerobic digestion (ATAD) has already reduced the heating cost. However, only a few studies have focused on reducing the aeration cost. Therefore, this study applied a two-step aeration control strategy to a fill-and-draw mode semicontinuous TAD process. The NADH-dependent fluorescence was monitored throughout the TAD experiment, and the aeration rate shifted according to the fluorescence intensity. As a result, the simple two-step aeration control operation achieved a 20.3% reduction in the total aeration, while maintaining an effective and stable operation. It is also expected that more savings can be achieved with a further reduction of the lower aeration rate or multisegmentation of the aeration rate. PMID:19190414

  16. Enhancement of ultrasonic disintegration of sewage sludge by aeration.

    PubMed

    Zhao, He; Zhang, Panyue; Zhang, Guangming; Cheng, Rong

    2016-04-01

    Sonication is an effective way for sludge disintegration, which can significantly improve the efficiency of anaerobic digestion to reduce and recycle use of sludge. But high energy consumption limits the wide application of sonication. In order to improve ultrasonic sludge disintegration efficiency and reduce energy consumption, aeration was introduced. Results showed that sludge disintegration efficiency was improved significantly by combining aeration with ultrasound. The aeration flow rate, gas bubble size, ultrasonic density and aeration timing had impacts on sludge disintegration efficiency. Aeration that used in later stage of ultrasonic irradiation with low aeration flow rate, small gas bubbles significantly improved ultrasonic disintegration sludge efficiency. At the optimal conditions of 0.4 W/mL ultrasonic irradiation density, 30 mL/min of aeration flow rate, 5 min of aeration in later stage and small gas bubbles, ultrasonic sludge disintegration efficiency was increased by 45% and one third of ultrasonic energy was saved. This approach will greatly benefit the application of ultrasonic sludge disintegration and strongly promote the treatment and recycle of wastewater sludge. PMID:27090707

  17. OXIDATION OF AS(III) BY AERATION AND STORAGE

    EPA Science Inventory

    A study of the effects of aeration and storage on the oxidation of arsenic(III) was undertaken at three utilities in the US to establish the engineering significance of aeration as a potential pre-treatment method for arsenic removal. The results of this study clearly establish t...

  18. Enhancement of ultrasonic disintegration of sewage sludge by aeration.

    PubMed

    Zhao, He; Zhang, Panyue; Zhang, Guangming; Cheng, Rong

    2016-04-01

    Sonication is an effective way for sludge disintegration, which can significantly improve the efficiency of anaerobic digestion to reduce and recycle use of sludge. But high energy consumption limits the wide application of sonication. In order to improve ultrasonic sludge disintegration efficiency and reduce energy consumption, aeration was introduced. Results showed that sludge disintegration efficiency was improved significantly by combining aeration with ultrasound. The aeration flow rate, gas bubble size, ultrasonic density and aeration timing had impacts on sludge disintegration efficiency. Aeration that used in later stage of ultrasonic irradiation with low aeration flow rate, small gas bubbles significantly improved ultrasonic disintegration sludge efficiency. At the optimal conditions of 0.4 W/mL ultrasonic irradiation density, 30 mL/min of aeration flow rate, 5 min of aeration in later stage and small gas bubbles, ultrasonic sludge disintegration efficiency was increased by 45% and one third of ultrasonic energy was saved. This approach will greatly benefit the application of ultrasonic sludge disintegration and strongly promote the treatment and recycle of wastewater sludge.

  19. FOULING OF FINE PORE DIFFUSED AERATORS: AN INTER- PLANT COMPARISON

    EPA Science Inventory

    There has been increasing interest in fine pore aeration systems, along with concerned about diffuser fouling and the subsequent loss of aeration efficiency. The objective of this study was to assess the relative fouling tendency of fine bubble diffusers t nine activated sludge ...

  20. 21 CFR 880.6100 - Ethylene oxide gas aerator cabinet.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide gas aerator cabinet. 880.6100... Miscellaneous Devices § 880.6100 Ethylene oxide gas aerator cabinet. (a) Identification. An ethyene oxide gas... sterilization. The device may include a heater to warm the circulating air. (b) Classification. Class...

  1. 21 CFR 880.6100 - Ethylene oxide gas aerator cabinet.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ethylene oxide gas aerator cabinet. 880.6100... Miscellaneous Devices § 880.6100 Ethylene oxide gas aerator cabinet. (a) Identification. An ethyene oxide gas... required to remove residual ethylene oxide (ETO) from wrapped medical devices that have undergone...

  2. 21 CFR 880.6100 - Ethylene oxide gas aerator cabinet.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ethylene oxide gas aerator cabinet. 880.6100... Miscellaneous Devices § 880.6100 Ethylene oxide gas aerator cabinet. (a) Identification. An ethyene oxide gas... required to remove residual ethylene oxide (ETO) from wrapped medical devices that have undergone...

  3. 21 CFR 880.6100 - Ethylene oxide gas aerator cabinet.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ethylene oxide gas aerator cabinet. 880.6100... Miscellaneous Devices § 880.6100 Ethylene oxide gas aerator cabinet. (a) Identification. An ethyene oxide gas... required to remove residual ethylene oxide (ETO) from wrapped medical devices that have undergone...

  4. Recirculation-aeration: Bibliography for aquaculture. Bibliographies and literature of agriculture (Final)

    SciTech Connect

    Perschbacher, P.W.; Powell, R.V.; Freeman, D.W.; Lorio, W.J.; Hanfman, D.T.

    1993-08-01

    The bibliography includes literature citations through 1992 related to water recirculation and aeration in aquaculture. The focus is on filtration, aeration, and circulation techniques in various aquaculture situations.

  5. Litter aeration and spread of Salmonella in broilers.

    PubMed

    Bodí, Sara González; Garcia, Arantxa Villagra; García, Santiago Vega; Orenga, Clara Marín

    2013-08-01

    Litter quality in the poultry sector is one of the main parameters of health, productivity, and animal welfare. Therefore, innovative management methods have been developed to improve the quality of litter. One of them is litter aeration (LA) by tumbling. However, there is little information related to the effect of this technique on the spreading of pathogens of public health importance such as Salmonella. In this context, the objective of this study was to determine the epidemiology of Salmonella in poultry farms, when serial LA were implemented during the rearing cycle of broilers. For this purpose, an experimental broiler farm with 3 identical rooms was used in the study. Two rooms were assigned to the LA treatment, and the other one served as the control room. Environmental samples were taken in poultry houses after LA in 4 consecutive weeks at the end of the cycle. All samples collected were analyzed according to the standards of the International Organization for Standardization (ISO 6579:2002, Annex D). The results of this study showed that in the control and treated rooms, the percentage of positive samples for Salmonella decreased in the first 3 LA sessions (LA 1, LA 2, and LA 3). However, in the last LA session of rearing (LA 4), the percentage of positive samples increased from 8.2 to 33.2% in the control room instead the treated rooms where the positive samples decreased (P = 0.017). Thus, the aeration of the litter as litter management technique in poultry broiler production does not increase the shedding or the spread of Salmonella throughout broiler houses. In addition, it could be an effective technique to reduce the infective pressure of this bacterium in several areas of the farm or in certain moments of the rearing period with more risk of multiplication and spreading of Salmonella. PMID:23873547

  6. Litter aeration and spread of Salmonella in broilers.

    PubMed

    Bodí, Sara González; Garcia, Arantxa Villagra; García, Santiago Vega; Orenga, Clara Marín

    2013-08-01

    Litter quality in the poultry sector is one of the main parameters of health, productivity, and animal welfare. Therefore, innovative management methods have been developed to improve the quality of litter. One of them is litter aeration (LA) by tumbling. However, there is little information related to the effect of this technique on the spreading of pathogens of public health importance such as Salmonella. In this context, the objective of this study was to determine the epidemiology of Salmonella in poultry farms, when serial LA were implemented during the rearing cycle of broilers. For this purpose, an experimental broiler farm with 3 identical rooms was used in the study. Two rooms were assigned to the LA treatment, and the other one served as the control room. Environmental samples were taken in poultry houses after LA in 4 consecutive weeks at the end of the cycle. All samples collected were analyzed according to the standards of the International Organization for Standardization (ISO 6579:2002, Annex D). The results of this study showed that in the control and treated rooms, the percentage of positive samples for Salmonella decreased in the first 3 LA sessions (LA 1, LA 2, and LA 3). However, in the last LA session of rearing (LA 4), the percentage of positive samples increased from 8.2 to 33.2% in the control room instead the treated rooms where the positive samples decreased (P = 0.017). Thus, the aeration of the litter as litter management technique in poultry broiler production does not increase the shedding or the spread of Salmonella throughout broiler houses. In addition, it could be an effective technique to reduce the infective pressure of this bacterium in several areas of the farm or in certain moments of the rearing period with more risk of multiplication and spreading of Salmonella.

  7. Changes in lung function and airway inflammation among asthmatic children residing in a woodsmoke-impacted urban area.

    PubMed

    Allen, Ryan W; Mar, Therese; Koenig, Jane; Liu, L-J Sally; Gould, Timothy; Simpson, Christopher; Larson, Timothy

    2008-02-01

    Fine particulate matter (PM(2.5)) is associated with respiratory effects, and asthmatic children are especially sensitive. Preliminary evidence suggests that combustion-derived particles play an important role. Our objective was to evaluate effect estimates from different PM(2.5) exposure metrics in relation to airway inflammation and lung function among children residing in woodsmoke-impacted areas of Seattle. Nineteen children (ages 6-13 yr) with asthma were monitored during the heating season. We measured 24-h outdoor and personal concentrations of PM(2.5) and light-absorbing carbon (LAC). Levoglucosan (LG), a marker of woodsmoke, was also measured outdoors. We partitioned PM(2.5) exposure into its ambient-generated (E(ag)) and nonambient (E(na)) components. These exposure metrics were evaluated in relation to daily changes in exhaled nitric oxide (FE(NO)), a marker of airway inflammation, and four lung function measures: midexpiratory flow (MEF), peak expiratory flow (PEF), forced expiratory volume in the first second (FEV(1)), and forced vital capacity (FVC). E(ag), but not E(na), was correlated with combustion markers. Significant associations with respiratory health were seen only among participants not using inhaled corticosteroids. Increases in FE(NO) were associated with personal PM(2.5), personal LAC, and E(ag) but not with ambient PM(2.5) or its combustion markers. In contrast, MEF and PEF decrements were associated with ambient PM(2.5), its combustion markers, and E(ag), but not with personal PM(2.5) or personal LAC. FEV(1) was associated only with ambient LG. Our results suggest that lung function may be especially sensitive to the combustion-generated component of ambient PM(2.5), whereas airway inflammation may be more closely related to some other constituent of the ambient PM(2.5) mixture. PMID:18302050

  8. Longitudinal micro-CT provides biomarkers of lung disease that can be used to assess the effect of therapy in preclinical mouse models, and reveal compensatory changes in lung volume.

    PubMed

    Vande Velde, Greetje; Poelmans, Jennifer; De Langhe, Ellen; Hillen, Amy; Vanoirbeek, Jeroen; Himmelreich, Uwe; Lories, Rik J

    2016-01-01

    In vivo lung micro-computed tomography (micro-CT) is being increasingly embraced in pulmonary research because it provides longitudinal information on dynamic disease processes in a field in which ex vivo assessment of experimental disease models is still the gold standard. To optimize the quantitative monitoring of progression and therapy of lung diseases, we evaluated longitudinal changes in four different micro-CT-derived biomarkers [aerated lung volume, lung tissue (including lesions) volume, total lung volume and mean lung density], describing normal development, lung infections, inflammation, fibrosis and therapy. Free-breathing mice underwent micro-CT before and repeatedly after induction of lung disease (bleomycin-induced fibrosis, invasive pulmonary aspergillosis, pulmonary cryptococcosis) and therapy (imatinib). The four lung biomarkers were quantified. After the last time point, we performed pulmonary function tests and isolated the lungs for histology. None of the biomarkers remained stable during longitudinal follow-up of adult healthy mouse lungs, implying that biomarkers should be compared with age-matched controls upon intervention. Early inflammation and progressive fibrosis led to a substantial increase in total lung volume, which affects the interpretation of aerated lung volume, tissue volume and mean lung density measures. Upon treatment of fibrotic lung disease, the improvement in aerated lung volume and function was not accompanied by a normalization of the increased total lung volume. Significantly enlarged lungs were also present in models of rapidly and slowly progressing lung infections. The data suggest that total lung volume changes could partly reflect a compensatory mechanism that occurs during disease progression in mice. Our findings underscore the importance of quantifying total lung volume in addition to aerated lung or lesion volumes to accurately document growth and potential compensatory mechanisms in mouse models of lung

  9. Longitudinal micro-CT provides biomarkers of lung disease that can be used to assess the effect of therapy in preclinical mouse models, and reveal compensatory changes in lung volume

    PubMed Central

    Vande Velde, Greetje; Poelmans, Jennifer; De Langhe, Ellen; Hillen, Amy; Vanoirbeek, Jeroen; Himmelreich, Uwe; Lories, Rik J.

    2016-01-01

    ABSTRACT In vivo lung micro-computed tomography (micro-CT) is being increasingly embraced in pulmonary research because it provides longitudinal information on dynamic disease processes in a field in which ex vivo assessment of experimental disease models is still the gold standard. To optimize the quantitative monitoring of progression and therapy of lung diseases, we evaluated longitudinal changes in four different micro-CT-derived biomarkers [aerated lung volume, lung tissue (including lesions) volume, total lung volume and mean lung density], describing normal development, lung infections, inflammation, fibrosis and therapy. Free-breathing mice underwent micro-CT before and repeatedly after induction of lung disease (bleomycin-induced fibrosis, invasive pulmonary aspergillosis, pulmonary cryptococcosis) and therapy (imatinib). The four lung biomarkers were quantified. After the last time point, we performed pulmonary function tests and isolated the lungs for histology. None of the biomarkers remained stable during longitudinal follow-up of adult healthy mouse lungs, implying that biomarkers should be compared with age-matched controls upon intervention. Early inflammation and progressive fibrosis led to a substantial increase in total lung volume, which affects the interpretation of aerated lung volume, tissue volume and mean lung density measures. Upon treatment of fibrotic lung disease, the improvement in aerated lung volume and function was not accompanied by a normalization of the increased total lung volume. Significantly enlarged lungs were also present in models of rapidly and slowly progressing lung infections. The data suggest that total lung volume changes could partly reflect a compensatory mechanism that occurs during disease progression in mice. Our findings underscore the importance of quantifying total lung volume in addition to aerated lung or lesion volumes to accurately document growth and potential compensatory mechanisms in mouse models of

  10. Longitudinal micro-CT provides biomarkers of lung disease that can be used to assess the effect of therapy in preclinical mouse models, and reveal compensatory changes in lung volume.

    PubMed

    Vande Velde, Greetje; Poelmans, Jennifer; De Langhe, Ellen; Hillen, Amy; Vanoirbeek, Jeroen; Himmelreich, Uwe; Lories, Rik J

    2016-01-01

    In vivo lung micro-computed tomography (micro-CT) is being increasingly embraced in pulmonary research because it provides longitudinal information on dynamic disease processes in a field in which ex vivo assessment of experimental disease models is still the gold standard. To optimize the quantitative monitoring of progression and therapy of lung diseases, we evaluated longitudinal changes in four different micro-CT-derived biomarkers [aerated lung volume, lung tissue (including lesions) volume, total lung volume and mean lung density], describing normal development, lung infections, inflammation, fibrosis and therapy. Free-breathing mice underwent micro-CT before and repeatedly after induction of lung disease (bleomycin-induced fibrosis, invasive pulmonary aspergillosis, pulmonary cryptococcosis) and therapy (imatinib). The four lung biomarkers were quantified. After the last time point, we performed pulmonary function tests and isolated the lungs for histology. None of the biomarkers remained stable during longitudinal follow-up of adult healthy mouse lungs, implying that biomarkers should be compared with age-matched controls upon intervention. Early inflammation and progressive fibrosis led to a substantial increase in total lung volume, which affects the interpretation of aerated lung volume, tissue volume and mean lung density measures. Upon treatment of fibrotic lung disease, the improvement in aerated lung volume and function was not accompanied by a normalization of the increased total lung volume. Significantly enlarged lungs were also present in models of rapidly and slowly progressing lung infections. The data suggest that total lung volume changes could partly reflect a compensatory mechanism that occurs during disease progression in mice. Our findings underscore the importance of quantifying total lung volume in addition to aerated lung or lesion volumes to accurately document growth and potential compensatory mechanisms in mouse models of lung

  11. Frequency characteristics of air-structural and structural sound transmission in human lungs

    NASA Astrophysics Data System (ADS)

    Shiryaev, A. D.; Korenbaum, V. I.

    2013-11-01

    From an independent sampling of data on luminal probing of the lungs of 20 people, based on an analysis of the phase characteristics of the coherency function of the signal with linear frequency modulation in a frequency band of 80-1000 Hz recorded above the trachea and different areas of the chest, the frequency selectivity of the structural and air-structural transmission variants has been revealed. It has been established that structural sound transmission on average is observed in a band from 100 to 280 Hz and air-structural propagation lies in the frequency range from 100 to 500-700 Hz. Over areas of the lungs characterized by the presence of aerated tissues (the apex and lower lobe), more frequently there is air-structural transmission, whereas in the vicinity of dense organs of the mediastinum (intercapsular region), on the contrary, structural propagation dominates.

  12. Computational fluid dynamics simulations of membrane filtration process adapted for water treatment of aerated sewage lagoons.

    PubMed

    Cano, Grégory; Mouahid, Adil; Carretier, Emilie; Guasp, Pascal; Dhaler, Didier; Castelas, Bernard; Moulin, Philippe

    2015-01-01

    The aim of this study is to apply the membrane bioreactor technology in an oxidation ditch in submerged conditions. This new wastewater filtration process will benefit rural areas (<5,000 population equivalent) subject to chronic water shortages by reusing this water for irrigation of green areas. For this purpose, the membranes developed without support are immersed in an aeration well and work in suction mode. The development of the membrane without support and more precisely the performance of spacers are approached by computational fluid dynamics in order to provide the best compromise between pressure drop/flow velocity and permeate flux. The numerical results on the layout and the membrane modules' geometry in the aeration well indicate that the optimal configuration is to install the membranes horizontally on three levels. Membranes should be connected to each other to a manifold providing a total membrane area of 18 m². Loss rate compared to the theoretical throughput is relatively low (less than 3%). Preliminary data obtained by modeling the lagoon provide access to its hydrodynamics, revealing that recirculation zones can be optimized by making changes in the operating conditions. The experimental validation of these results and taking into account the aeration in the numerical models are underway. PMID:25633942

  13. Computational fluid dynamics simulations of membrane filtration process adapted for water treatment of aerated sewage lagoons.

    PubMed

    Cano, Grégory; Mouahid, Adil; Carretier, Emilie; Guasp, Pascal; Dhaler, Didier; Castelas, Bernard; Moulin, Philippe

    2015-01-01

    The aim of this study is to apply the membrane bioreactor technology in an oxidation ditch in submerged conditions. This new wastewater filtration process will benefit rural areas (<5,000 population equivalent) subject to chronic water shortages by reusing this water for irrigation of green areas. For this purpose, the membranes developed without support are immersed in an aeration well and work in suction mode. The development of the membrane without support and more precisely the performance of spacers are approached by computational fluid dynamics in order to provide the best compromise between pressure drop/flow velocity and permeate flux. The numerical results on the layout and the membrane modules' geometry in the aeration well indicate that the optimal configuration is to install the membranes horizontally on three levels. Membranes should be connected to each other to a manifold providing a total membrane area of 18 m². Loss rate compared to the theoretical throughput is relatively low (less than 3%). Preliminary data obtained by modeling the lagoon provide access to its hydrodynamics, revealing that recirculation zones can be optimized by making changes in the operating conditions. The experimental validation of these results and taking into account the aeration in the numerical models are underway.

  14. Chronic lung injury risk estimates for urban areas having ozone patterns similar to those in the Northeast

    SciTech Connect

    Absil, M.; Narducci, P.; Whitfield, R.; Richmond, H.M.

    1991-12-31

    This paper describes the approach and result of an assessment of health risks associated with long-term exposure to ozone. The health endpoint of interest is the probability of formation of mild lesions in the centriacinar region of the lung among children living in New York City. The risk model incorporates an exposure model and a health model. The exposure model is preliminary results of the probabilistic NAAQS Exposure Model (P-NEM) for ozone, and the health model is the judgments of active researchers about the likelihood of formation of ozone-induced lesions in the human lung. Children and New York City were chosen as the population and city of interest because it is believed that children are more sensitive to ozone than any other group of people, and New York City is more representative of other urban areas than Los Angeles, the other city of which P-NEM exposure results are available. Risk results are presented for ten exposure distributions generated by P-NEM, two air quality scenarios (``as-is`` and ``attainment``), and two exposure periods (1 and 10 ozone seasons). The results vary across experts, are not very sensitive to variations in P-NEM exposure distributions, are lower for attainment conditions than as-is conditions, and are lower for 1 season of exposure than 10 seasons. Although these results are specific to children living in areas having exposure patterns similar to those found in the Northeast, they are fairly representative of results for outdoor workers in the Northeast and Southern California and for children in Southern California. The reason for this is that many experts believe that children and outdoor workers respond in a similar fashion to the given exposure patterns, or that exposure patterns in the Northeast and Southern California are similar. Some experts held both of these beliefs. These results should help policymakers evaluate alternative national ambient air quality standards for ozone. 4 refs., 9 figs., 3 tabs.

  15. Effect of aeration rate on composting of penicillin mycelial dreg.

    PubMed

    Chen, Zhiqiang; Zhang, Shihua; Wen, Qinxue; Zheng, Jun

    2015-11-01

    Pilot scale experiments with forced aeration were conducted to estimate effects of aeration rates on the performance of composting penicillin mycelial dreg using sewage sludge as inoculation. Three aeration rates of 0.15, 0.50 and 0.90L/(min·kg) organic matter (OM) were examined. The principal physicochemical parameters were monitored during the 32day composting period. Results showed that the higher aeration rate of 0.90L/(min·kg) did not corresponded to a longer thermophilic duration and higher rates of OM degradation; but the lower aeration rate of 0.15L/(min·kg) did induce an accumulation of NH4(+)-N contents due to the inhibition of nitrification. On the other hand, aeration rate has little effect on degradation of penicillin. The results show that the longest phase of thermophilic temperatures≥55°C, the maximum NO3(-)-N content and seed germination, and the minimum C/N ratio were obtained with 0.50L/(min·kg) OM. Therefore, aeration rates of 0.50L/(min·kg) OM can be recommended for composting penicillin mycelial dreg.

  16. Effect of aeration rate on composting of penicillin mycelial dreg.

    PubMed

    Chen, Zhiqiang; Zhang, Shihua; Wen, Qinxue; Zheng, Jun

    2015-11-01

    Pilot scale experiments with forced aeration were conducted to estimate effects of aeration rates on the performance of composting penicillin mycelial dreg using sewage sludge as inoculation. Three aeration rates of 0.15, 0.50 and 0.90L/(min·kg) organic matter (OM) were examined. The principal physicochemical parameters were monitored during the 32day composting period. Results showed that the higher aeration rate of 0.90L/(min·kg) did not corresponded to a longer thermophilic duration and higher rates of OM degradation; but the lower aeration rate of 0.15L/(min·kg) did induce an accumulation of NH4(+)-N contents due to the inhibition of nitrification. On the other hand, aeration rate has little effect on degradation of penicillin. The results show that the longest phase of thermophilic temperatures≥55°C, the maximum NO3(-)-N content and seed germination, and the minimum C/N ratio were obtained with 0.50L/(min·kg) OM. Therefore, aeration rates of 0.50L/(min·kg) OM can be recommended for composting penicillin mycelial dreg. PMID:26574101

  17. Increased Mortality of Respiratory Diseases, Including Lung Cancer, in the Area with Large Amount of Ashfall from Mount Sakurajima Volcano

    PubMed Central

    Higuchi, Kenta; Koriyama, Chihaya; Akiba, Suminori

    2012-01-01

    Objectives. Mount Sakurajima in Japan is one of the most active volcanoes in the world. This work was conducted to examine the effect of volcanic ash on the chronic respiratory disease mortality in the vicinity of Mt. Sakurajima. Methods. The present work examined the standardized mortality ratios (SMRs) of respiratory diseases during the period 1968–2002 in Sakurajima town and Tarumizu city, where ashfall from the volcano recorded more than 10.000 g/m2/yr on average in the 1980s. Results. The SMR of lung cancer in the Sakurajima-Tarumizu area was 1.61 (95% CI = 1.44–1.78) for men and 1.67 (95% CI = 1.39–1.95) for women while it was nearly equal to one in Kanoya city, which neighbors Tarumizu city but located at the further position from Mt. Sakurajima, and therefore has much smaller amounts of ashfall. Sakurajima-Tarumizu area had elevated SMRs for COPDs and acute respiratory diseases while Kanoya did not. Conclusions. Cristobalite is the most likely cause of the increased deaths from those chronic respiratory diseases since smoking is unlikely to explain the increased mortality of respiratory diseases among women since the proportion of smokers in Japanese women is less than 20%, and SPM levels in the Sakurajima-Tarumizu area were not high. Further studies seem warranted. PMID:22536275

  18. Lung cancer mortality reduction after installation of tap-water supply system in an arseniasis-endemic area in Southwestern Taiwan.

    PubMed

    Chiu, Hui-Fen; Ho, Shu-Chen; Yang, Chun-Yuh

    2004-12-01

    Arsenic has been well documented as the major risk factor for blackfoot disease (BFD), a unique peripheral vascular disease (PVD) that was endemic in the Southwestern coast of Taiwan, where residents had used high-arsenic artesian well water for more than 50 years. Long-term arsenic exposure has also been reported to associated with lung cancer mortality in a dose-response relationship. A tap-water supply system was implemented in the early 1960s in the BFD-endemic areas. Artesian well water was no longer used for drinking and cooking after the mid-1970s. The objective of this study is to examine whether lung cancer mortality decreased after the improvement of drinking water supply system through elimination of arsenic exposure from artesian well water. Standardized mortality ratios (SMRs) for lung cancer were calculated for the BFD-endemic area for the years 1971-2000. The study results show that mortality from lung cancer declined gradually after the improvement of drinking water supply system to eliminate arsenic exposure from artesian well water. Based on the reversibility criterion, the association between arsenic exposure and lung cancer mortality is likely to be causal. PMID:15541810

  19. Lung cancer mortality reduction after installation of tap-water supply system in an arseniasis-endemic area in Southwestern Taiwan.

    PubMed

    Chiu, Hui-Fen; Ho, Shu-Chen; Yang, Chun-Yuh

    2004-12-01

    Arsenic has been well documented as the major risk factor for blackfoot disease (BFD), a unique peripheral vascular disease (PVD) that was endemic in the Southwestern coast of Taiwan, where residents had used high-arsenic artesian well water for more than 50 years. Long-term arsenic exposure has also been reported to associated with lung cancer mortality in a dose-response relationship. A tap-water supply system was implemented in the early 1960s in the BFD-endemic areas. Artesian well water was no longer used for drinking and cooking after the mid-1970s. The objective of this study is to examine whether lung cancer mortality decreased after the improvement of drinking water supply system through elimination of arsenic exposure from artesian well water. Standardized mortality ratios (SMRs) for lung cancer were calculated for the BFD-endemic area for the years 1971-2000. The study results show that mortality from lung cancer declined gradually after the improvement of drinking water supply system to eliminate arsenic exposure from artesian well water. Based on the reversibility criterion, the association between arsenic exposure and lung cancer mortality is likely to be causal.

  20. INVESTIGATIONS INTO BIOFOULING PHENOMENA IN FINE PORE AERATION DEVICES

    EPA Science Inventory

    Microbiologically-based procedures were used to describe biofouling phenomena on fine pore aeration devices and to determine whether biofilm characteristics could be related to diffuser process performance parameters. Fine pore diffusers were obtained from five municipal wastewa...

  1. Nanoquartz in Late Permian C1 coal and the high incidence of female lung cancer in the Pearl River Origin area: a retrospective cohort study

    PubMed Central

    Tian, Linwei; Dai, Shifeng; Wang, Jianfang; Huang, Yunchao; Ho, Suzanne C; Zhou, Yiping; Lucas, Donald; Koshland, Catherine P

    2008-01-01

    Background The Pearl River Origin area, Qujing District of Yunnan Province, has one of the highest female lung cancer mortality rates in China. Smoking was excluded as a cause of the lung cancer excess because almost all women were non-smokers. Crystalline silica embedded in the soot emissions from coal combustion was found to be associated with the lung cancer risk in a geographical correlation study. Lung cancer rates tend to be higher in places where the Late Permian C1 coal is produced. Therefore, we have hypothesized the two processes: C1 coal combustion --> nanoquartz in ambient air --> lung cancer excess in non-smoking women. Methods/Design We propose to conduct a retrospective cohort study to test the hypothesis above. We will search historical records and compile an inventory of the coal mines in operation during 1930–2009. To estimate the study subjects' retrospective exposure, we will reconstruct the historical exposure scenario by burning the coal samples, collected from operating or deserted coal mines by coal geologists, in a traditional firepit of an old house. Indoor air particulate samples will be collected for nanoquartz and polycyclic aromatic hydrocarbons (PAHs) analyses. Bulk quartz content will be quantified by X-ray diffraction analysis. Size distribution of quartz will be examined by electron microscopes and by centrifugation techniques. Lifetime cumulative exposure to nanoquartz will be estimated for each subject. Using the epidemiology data, we will examine whether the use of C1 coal and the cumulative exposure to nanoquartz are associated with an elevated risk of lung cancer. Discussion The high incidence rate of lung cancer in Xuan Wei, one of the counties in the current study area, was once attributed to high indoor air concentrations of PAHs. The research results have been cited for qualitative and quantitative cancer risk assessment of PAHs by the World Health Organization and other agencies. If nanoquartz is found to be the main

  2. Unilateral pleural effusion in an animal model: evaluation of lung function with EBCT

    NASA Astrophysics Data System (ADS)

    Recheis, Wolfgang A.; Pallwein, Leo; Soegner, Peter; Faschingbauer, Ralph; Schmidbauer, Georg; Kleinsasser, Axel; Loeckinger, Alexander; Hoermann, Christoph; zur Nedden, Dieter

    2003-05-01

    The purpsoe was to evaluate the influence of a right-sided pleural effusion on the lung aeration dynamics in the respiratory cycle during pressure controlled ventilation. Pleural effusion was simulated by infusion of 3% gelatin into the pleural cavity in steps of 300ml totaling 1200ml in four anesthetized pigs. After each step, volume scans and respirator gated 50ms scans at a constant table position (carina niveau) were taken. The dynamic changes of the previously defined air-tissue ratios (in steps of 100HU) were evaluated in three separate regions of left and right lung: a ventral, an intermediate and a dorsal area. The affected side revealed dramatic alveolar collapse. There was a shift of the lung density to higher air-tissue ratios (+200HU) but showing the same air-tissue ratio dynamics. A slight lateral shift of 32mm (+/-14mm) the mediastinum was measured. The unaffected side showed no increase in the air-tissue ratios caused by hyperinflation but an increase of density due to mediastinal shift. Air-tissue ratio dynamics remained unchanged on the unaffected side compared to baseline measurements. We visualized the ventilation mismatch caused by pleural effusion. The contra-lateral lung is not affected by unilateral pleural effusion. Pressure controlled ventilation prevents hyper-inflation of non-dependent lung areas.

  3. [Improvement of River Water Quality by Aeration: WASP Model Study].

    PubMed

    Zhu, Wen-bo; Wang, Hong-xiu; Liu, Cui; Zhang, Jian; Liang, Shuang

    2015-04-01

    Aeration is one of the main technical methods to remediate polluted rivers, and mathematical models are the main ways to predict and assess the environmental pollution. WASP model was used to study the effect of aeration on improving the water quality of a small river over a time span. The preliminary results showed that the simulation values were consistent with practical monitoring data, which could be useful for the management and control of polluted water. Furthermore, simulations under different aeration conditions suggested that aeration technology could significantly lower the levels of chemical oxygen demand (COD) and ammonia-nitrogen (NH4(+)-N) of river water, thus improving the water quality. With the improvement of dissolved oxygen (DO), the water quality could be further improved. However, the increase in the removal rate of pollutants would slow down. Also, there were remarkable differences among various months throughout the whole year, and aeration from May to September had better results. Considering economic costs and environmental benefits, river aeration with a 4 mg x L(1) DO standard in summer was determined as the best condition.

  4. Generating CO(2)-credits through landfill in situ aeration.

    PubMed

    Ritzkowski, M; Stegmann, R

    2010-04-01

    Landfills are some of the major anthropogenic sources of methane emissions worldwide. The installation and operation of gas extraction systems for many landfills in Europe and the US, often including technical installations for energy recovery, significantly reduced these emissions during the last decades. Residual landfill gas, however, is still continuously produced after the energy recovery became economically unattractive, thus resulting in ongoing methane emissions for many years. By landfill in situ aeration these methane emissions can be widely avoided both, during the aeration process as well as in the subsequent aftercare period. Based on model calculations and online monitoring data the amount of avoided CO(2-eq). can be determined. For an in situ aerated landfill in northern Germany, acting as a case study, 83-95% (depending on the kind and quality of top cover) of the greenhouse gas emission potential could be reduced under strictly controlled conditions. Recently the United Nations Framework Convention on Climate Change (UNFCCC) has approved a new methodology on the "Avoidance of landfill gas emissions by in situ aeration of landfills" (UNFCCC, 2009). Based on this methodology landfill aeration projects might be considered for generation of Certified Emission Reductions (CERs) in the course of CDM projects. This paper contributes towards an evaluation of the potential of landfill aeration for methane emissions reduction.

  5. Enhancement of Nitrogen Removal in an Intermittent Aeration Membrane Bioreactor

    NASA Astrophysics Data System (ADS)

    He, Xiaojuan; Wisniewski, Christelle; Li, Xudong; Zhou, Qi

    2010-11-01

    An intermittent aerated membrane bioreactor was applied in laboratory scale to treat synthetic household wastewater. The system organic load and nitrogen load were 0.34 kgCODṡm-3ṡd-1 and 0.06 kgTNṡm-3ṡd-1, respectively. The hydraulic residence time was equal to 12 h and very long sludge residence times were imposed. Intermittent aeration, with anoxic-aerobic cycle of 30/60 minutes, was employed in the system. The results showed that 100% SS and >90% COD could be removed. The average removal efficiency of NH4-N and TN was 99.7% and 80%, respectively. A linear relationship between the fouling rate and the MLSS, MLVSS concentration was founded. The denitrification seemed to be the rate-limiting step for nitrogen removal. To enhance denitrification, the following strategies could be considered: 1) to select suitable aeration/non-aeration cycle, 2) to control the aeration intensity, 3) to feed the system at the beginning of non-aeration period, 4) to maintain high MLSS concentration.

  6. Ventilatory lung function and chronic chest symptoms among the inhabitants of urban areas with various levels of acid aerosols: prospective study in Cracow

    SciTech Connect

    Jedrychowski, W.; Krzyzanowski, M.

    1989-02-01

    The analysis carried out earlier in Cracow showed that the high level of SO/sub 2/ and particulate matter (PM) alone cannot be responsible for an excess of chronic chest symptoms and faster lung function deterioration in the population at large. To check the hypothesis that acid aerosols present in the urban air may cause substantial damage of the lungs, data from a 13-year follow-up survey of chronic chest diseases in Cracow (1968-1981) have been reanalyzed. In the plan of the analysis, three areas of the city with various levels of sulfate and sulfur transformation ratio (STR) in the urban air have been defined. In each of the defined areas, the prevalence of chronic chest symptoms, as well as lung function decline, have been studied. In total, the lung function study group consisted of 1414 persons (584 males and 830 females). Those men who lived in the area with the higher sulfate and STR had lower FEV1 levels by about 151 mL than did the residents of the other areas, and this was equivalent to the effect of smoking. In females, the pattern was generally the same. In men, the FEV1 decline rate (mL/year) over the 13-year period was significantly faster by about 11 mL/year in the areas with higher and intermediate STR, which was again equivalent to the effect of smoking. It was found that the level of SO/sub 2/ and PM in the urban air correlated with the symptom prevalence in women; however, it had no clear impact on lung function deterioration.

  7. Ventilatory lung function and chronic chest symptoms among the inhabitants of urban areas with various levels of acid aerosols: prospective study in Cracow.

    PubMed

    Jedrychowski, W; Krzyzanowski, M

    1989-02-01

    The analysis carried out earlier in Cracow showed that the high level of SO2 and particulate matter (PM) alone cannot be responsible for an excess of chronic chest symptoms and faster lung function deterioration in the population at large. To check the hypothesis that acid aerosols present in the urban air may cause substantial damage of the lungs, data from a 13-year follow-up survey of chronic chest diseases in Cracow (1968-1981) have been reanalyzed. In the plan of the analysis, three areas of the city with various levels of sulfate and sulfur transformation ratio (STR) in the urban air have been defined. In each of the defined areas, the prevalence of chronic chest symptoms, as well as lung function decline, have been studied. In total, the lung function study group consisted of 1414 persons (584 males and 830 females). Those men who lived in the area with the higher sulfate and STR had lower FEV1 levels by about 151 mL than did the residents of the other areas, and this was equivalent to the effect of smoking. In females, the pattern was generally the same. In men, the FEV1 decline rate (mL/year) over the 13-year period was significantly faster by about 11 mL/year in the areas with higher and intermediate STR, which was again equivalent to the effect of smoking. It was found that the level of SO2 and PM in the urban air correlated with the symptom prevalence in women; however, it had no clear impact on lung function deterioration.

  8. A new step aeration approach towards the improvement of nitrogen removal in a full scale Carrousel oxidation ditch.

    PubMed

    Jin, Pengkang; Wang, Xianbao; Wang, Xiaochang; Ngo, Huu Hao; Jin, Xin

    2015-12-01

    Two aeration modes, step aeration and point aeration, were used in a full-scale Carrousel oxidation ditch with microporous aeration. The nitrogen removal performance and mechanism were analyzed. With the same total aeration input, both aeration modes demonstrated good nitrification outcomes with the average efficiency in removing NH4(+)-N of more than 98%. However, the average removal efficiencies for total nitrogen were 89.3% and 77.6% under step aeration and point aeration, respectively. The results indicated that an extended aerobic zone followed the aeration zones could affect the proportion of anoxic and oxic zones. The step aeration with larger anoxic zones indicated better TN removal efficiency. More importantly, step aeration provided the suitable environment for both nitrifiers and denitrifiers. The diversity and relative abundance of denitrifying bacteria under the step aeration (1.55%) was higher than that under the point aeration (1.12%), which resulted in an overall higher TN removal efficiency.

  9. Characterization of Odorant Compounds from Mechanical Aerated Pile Composting and Static Aerated Pile Composting.

    PubMed

    Kumari, Priyanka; Lee, Joonhee; Choi, Hong-Lim

    2016-04-01

    We studied airborne contaminants (airborne particulates and odorous compounds) emitted from compost facilities in South Korea. There are primarily two different types of composting systems operating in Korean farms, namely mechanical aerated pile composting (MAPC) and aerated static pile composting (SAPC). In this study, we analyzed various particulate matters (PM10, PM7, PM2.5, PM1, and total suspended particles), volatile organic compounds and ammonia, and correlated these airborne contaminants with microclimatic parameters, i.e., temperature and relative humidity. Most of the analyzed airborne particulates (PM7, PM2.5, and PM1) were detected in high concentration at SAPC facilities compered to MAPC; however these differences were statistically non-significant. Similarly, most of the odorants did not vary significantly between MAPC and SAPC facilities, except for dimethyl sulfide (DMS) and skatole. DMS concentrations were significantly higher in MAPC facilities, whereas skatole concentrations were significantly higher in SAPC facilities. The microclimate variables also did not vary significantly between MAPC and SAPC facilities, and did not correlate significantly with most of the airborne particles and odorous compounds, suggesting that microclimate variables did not influence their emission from compost facilities. These findings provide insight into the airborne contaminants that are emitted from compost facilities and the two different types of composting agitation systems. PMID:26949962

  10. Characterization of Odorant Compounds from Mechanical Aerated Pile Composting and Static Aerated Pile Composting

    PubMed Central

    Kumari, Priyanka; Lee, Joonhee; Choi, Hong-Lim

    2016-01-01

    We studied airborne contaminants (airborne particulates and odorous compounds) emitted from compost facilities in South Korea. There are primarily two different types of composting systems operating in Korean farms, namely mechanical aerated pile composting (MAPC) and aerated static pile composting (SAPC). In this study, we analyzed various particulate matters (PM10, PM7, PM2.5, PM1, and total suspended particles), volatile organic compounds and ammonia, and correlated these airborne contaminants with microclimatic parameters, i.e., temperature and relative humidity. Most of the analyzed airborne particulates (PM7, PM2.5, and PM1) were detected in high concentration at SAPC facilities compered to MAPC; however these differences were statistically non-significant. Similarly, most of the odorants did not vary significantly between MAPC and SAPC facilities, except for dimethyl sulfide (DMS) and skatole. DMS concentrations were significantly higher in MAPC facilities, whereas skatole concentrations were significantly higher in SAPC facilities. The microclimate variables also did not vary significantly between MAPC and SAPC facilities, and did not correlate significantly with most of the airborne particles and odorous compounds, suggesting that microclimate variables did not influence their emission from compost facilities. These findings provide insight into the airborne contaminants that are emitted from compost facilities and the two different types of composting agitation systems. PMID:26949962

  11. [Research of controlling condition for aeration stabilization pond dealing with sanitary waste of countryside].

    PubMed

    Li, Huai-Zheng; Yao, Shu-Jun; Xu, Zu-Xin; Chen, Wei-Bing

    2012-10-01

    According to research of some problems, such as the hydraulic detention time that aeration stabilization pond deals with sanitary waste of countryside, dissolved oxygen in pond during the process of aeration, the concentration distribution of sludge and different aeration periods affecting on the treatment efficiency, we can acquire good treatment efficiency and energy consumption of economy. The results indicate that under the aeration stabilization pond of this experiment, 4 d is the best hydraulic detention time with this aeration stabilization pond. Time of the discontinuous running aeration should be greater than 15 min. The concentration distribution of sludge can reach equilibrium at each point of aeration stabilization pond between 2 min and 10 min. The best aeration period of dislodging the pollutant is 0.5 h aeration/1.0 h cut-off.

  12. [Status of lung function in females of a North Rhine-Westphalia rural and urban-industrial area].

    PubMed

    Islam, M S; Dolgner, R; Schlipköter, H W

    1990-02-01

    A comparative investigation of the pulmonary function status was carried out in women, aged between 52 and 56 years, from a rural and a municipal industrial area in North Rhine Westphalia. A questionnaire that the subjects had to complete themselves, provided us with information on personal medical history, smoking habits, the nature of domestic heating, and social status (education). The function tests were performed in a mobile pulmonary function laboratory (Jäger, Inc.). The airway resistance (Raw) and the intrathoracic gas volume (ITGV) were measured with the aid of a constant-volume body plethysmograph; a pneumotachographic system was employed to measure the ventilatory pulmonary function. All lung volumes were recalculated in terms of BTPS, and expressed as a percentage of the predicted values. Women from Leverkusen complained somewhat more frequently of hay fever, allergies of all kinds, and non-respiratory disturbances, than did women from Borken. In contrast, respiratory symptoms were indicated equally frequently in both areas. In the case of the Leverkusen group, a mean Raw of 0.323 +/- 0.183 kPa.1-1.s, was obtained, and in the case of the Borken group, a mean Raw of 0.258 +/- 0.182 kPa.1-1.s; this difference is statistically significant (p less than 0.05). On average, the women from Leverkusen also had a significantly higher SRaw (p less than 0.005) and ITGV (p less than 0.05) than did the women from Borken. These results argue in favour of a negative influence of air pollution on the pulmonary function.

  13. Seasonal variations and aeration effects on water quality improvements and physiological responses of Nymphaea tetragona Georgi.

    PubMed

    Lu, Xiao-Ming; Lu, Peng-Zhen; Huang, Min-Sheng; Dai, Ling-Peng

    2013-01-01

    Seasonal variations and aeration effects on water quality improvements and the physiological responses of Nymphaea tetragona Georgi were investigated with mesocosm experiments. Plants were hydroponically cultivated in six purifying tanks (aerated, non-aerated) and the characteristics of the plants were measured. Water quality improvements in purifying tanks were evaluated by comparing to the control tanks. The results showed that continuous aeration affected the plant morphology and physiology. The lengths of the roots, petioles and leaf limbs in aeration conditions were shorter than in non-aeration conditions. Chlorophyll and soluble protein contents of the leaf limbs in aerated tanks decreased, while peroxidase and catalase activities of roots tissues increased. In spring and summer, effects of aeration on the plants were less than in autumn. Total nitrogen (TN) and ammonia nitrogen (NH4(+)-N) in aerated tanks were lower than in non-aerated tanks, while total phosphorus (TP) and dissolved phosphorus (DP) increased in spring and summer. In autumn, effects of aeration on the plants became more significant. TN, NH4(+)-N, TP and DP became higher in aerated tanks than in non-aerated tanks in autumn. This work provided evidences for regulating aeration techniques based on seasonal variations of the plant physiology in restoring polluted stagnant water.

  14. Seasonal variations and aeration effects on water quality improvements and physiological responses of Nymphaea tetragona Georgi.

    PubMed

    Lu, Xiao-Ming; Lu, Peng-Zhen; Huang, Min-Sheng; Dai, Ling-Peng

    2013-01-01

    Seasonal variations and aeration effects on water quality improvements and the physiological responses of Nymphaea tetragona Georgi were investigated with mesocosm experiments. Plants were hydroponically cultivated in six purifying tanks (aerated, non-aerated) and the characteristics of the plants were measured. Water quality improvements in purifying tanks were evaluated by comparing to the control tanks. The results showed that continuous aeration affected the plant morphology and physiology. The lengths of the roots, petioles and leaf limbs in aeration conditions were shorter than in non-aeration conditions. Chlorophyll and soluble protein contents of the leaf limbs in aerated tanks decreased, while peroxidase and catalase activities of roots tissues increased. In spring and summer, effects of aeration on the plants were less than in autumn. Total nitrogen (TN) and ammonia nitrogen (NH4(+)-N) in aerated tanks were lower than in non-aerated tanks, while total phosphorus (TP) and dissolved phosphorus (DP) increased in spring and summer. In autumn, effects of aeration on the plants became more significant. TN, NH4(+)-N, TP and DP became higher in aerated tanks than in non-aerated tanks in autumn. This work provided evidences for regulating aeration techniques based on seasonal variations of the plant physiology in restoring polluted stagnant water. PMID:23819294

  15. Effect of surfactant on regional lung function in an experimental model of respiratory distress syndrome in rabbit.

    PubMed

    Bayat, Sam; Porra, Liisa; Broche, Ludovic; Albu, Gergely; Malaspinas, Iliona; Doras, Camille; Strengell, Satu; Peták, Ferenc; Habre, Walid

    2015-08-01

    We assessed the changes in regional lung function following instillation of surfactant in a model of respiratory distress syndrome (RDS) induced by whole lung lavage and mechanical ventilation in eight anaesthetized, paralyzed, and mechanically ventilated New Zealand White rabbits. Regional specific ventilation (sV̇) was measured by K-edge subtraction synchrotron computed tomography during xenon washin. Lung regions were classified as poorly aerated (PA), normally aerated (NA), or hyperinflated (HI) based on regional density. A functional category was defined within each class based on sV̇ distribution (High, Normal, and Low). Airway resistance (Raw), respiratory tissue damping (G), and elastance (H) were measured by forced oscillation technique at low frequencies before and after whole lung saline lavage-induced (100 ml/kg) RDS, and 5 and 45 min after intratracheal instillation of beractant (75 mg/kg). Surfactant instillation improved Raw, G, and H (P < 0.05 each), and gas exchange and decreased atelectasis (P < 0.001). It also significantly improved lung aeration and ventilation in atelectatic lung regions. However, in regions that had remained normally aerated after lavage, it decreased regional aeration and increased sV̇ (P < 0.001) and sV̇ heterogeneity. Although surfactant treatment improved both central airway and tissue mechanics and improved regional lung function of initially poorly aerated and atelectatic lung, it deteriorated regional lung function when local aeration was normal prior to administration. Local mechanical and functional heterogeneity can potentially contribute to the worsening of RDS and gas exchange. These data underscore the need for reassessing the benefits of routine prophylactic vs. continuous positive airway pressure and early "rescue" surfactant therapy in very immature infants. PMID:25997942

  16. Numerical simulation of landfill aeration using computational fluid dynamics.

    PubMed

    Fytanidis, Dimitrios K; Voudrias, Evangelos A

    2014-04-01

    The present study is an application of Computational Fluid Dynamics (CFD) to the numerical simulation of landfill aeration systems. Specifically, the CFD algorithms provided by the commercial solver ANSYS Fluent 14.0, combined with an in-house source code developed to modify the main solver, were used. The unsaturated multiphase flow of air and liquid phases and the biochemical processes for aerobic biodegradation of the organic fraction of municipal solid waste were simulated taking into consideration their temporal and spatial evolution, as well as complex effects, such as oxygen mass transfer across phases, unsaturated flow effects (capillary suction and unsaturated hydraulic conductivity), temperature variations due to biochemical processes and environmental correction factors for the applied kinetics (Monod and 1st order kinetics). The developed model results were compared with literature experimental data. Also, pilot scale simulations and sensitivity analysis were implemented. Moreover, simulation results of a hypothetical single aeration well were shown, while its zone of influence was estimated using both the pressure and oxygen distribution. Finally, a case study was simulated for a hypothetical landfill aeration system. Both a static (steadily positive or negative relative pressure with time) and a hybrid (following a square wave pattern of positive and negative values of relative pressure with time) scenarios for the aeration wells were examined. The results showed that the present model is capable of simulating landfill aeration and the obtained results were in good agreement with corresponding previous experimental and numerical investigations.

  17. Pure and aerated water entry of a flat plate

    NASA Astrophysics Data System (ADS)

    Ma, Z. H.; Causon, D. M.; Qian, L.; Mingham, C. G.; Mai, T.; Greaves, D.; Raby, A.

    2016-01-01

    This paper presents an experimental and numerical investigation of the entry of a rigid square flat plate into pure and aerated water. Attention is focused on the measurement and calculation of the slamming loads on the plate. The experimental study was carried out in the ocean basin at Plymouth University's COAST laboratory. The present numerical approach extends a two-dimensional hydro-code to compute three-dimensional hydrodynamic impact problems. The impact loads on the structure computed by the numerical model compare well with laboratory measurements. It is revealed that the impact loading consists of distinctive features including (1) shock loading with a high pressure peak, (2) fluid expansion loading associated with very low sub-atmospheric pressure close to the saturated vapour pressure, and (3) less severe secondary reloading with super-atmospheric pressure. It is also disclosed that aeration introduced into water can effectively reduce local pressures and total forces on the flat plate. The peak impact loading on the plate can be reduced by half or even more with 1.6% aeration in water. At the same time, the lifespan of shock loading is prolonged by aeration, and the variation of impulse is less sensitive to the change of aeration than the peak loading.

  18. Evaluation of design factors for a cascade aerator to enhance the efficiency of an oxidation pond for ferruginous mine drainage.

    PubMed

    Oh, Chamteut; Ji, Sangwoo; Cheong, Youngwook; Yim, Giljae; Hong, Ji-Hye

    2016-10-01

    This research focused on the optimum design of a cascade aerator to enhance the efficiency of an oxidation pond in a passive treatment system for remediating ferruginous mine drainage. For this purpose, various aeration experiments with aerators of different drop heights (0-4 m) and formations (types A and B) were executed on mine drainage. Type A simply drops the mine drainage into the oxidation pond while type B sprays the mine drainage and retains it for 8 min in each step. The efficiency enhancement of the oxidation pond was strongly dependent on the increase in pH and DO of the mine drainage discharged into the pond. The water quality improved with the increase in drop height but especially showed better effect with type B. The reasons for this result were attributed to the increase of contact surface and retention time of the mine drainage. The cascade aerator, therefore, should be designed to be as high as possible with the assistance of spraying form and retention time of the mine drainage to maximize the efficiency of the oxidation pond. These effects could be evaluated by calculating required areas of the oxidation pond for 95% of Fe(2+) oxidation.

  19. Recirculation or artificial aeration in vertical flow constructed wetlands: a comparative study for treating high load wastewater.

    PubMed

    Foladori, Paola; Ruaben, Jenny; Ortigara, Angela R C

    2013-12-01

    Vertical subsurface-flow constructed wetlands at pilot-scale have been applied to treat high hydraulic and organic loads by implementing the following configurations: (1) intermittent recirculation of the treated wastewater from the bottom to the top of the bed, (2) intermittent artificial aeration supplied at the bottom of the bed and (3) the combination of both. These configurations were operated with a saturated bottom layer for a 6h-treatment phase, followed by a free drainage phase prior to a new feeding. COD removal efficiency was 85-90% in all the configurations and removed loads were 54-70 gCOD m(-2)d(-1). The aerated and recirculated wetland resulted in a higher total nitrogen removal (8.6 gN m(-2)d(-1)) due to simultaneous nitrification/denitrification, even in the presence of intermittent aeration (6.8 Nm(3)m(-2)d(-1)). The extra investment needed for implementing aeration/recirculation would be compensated for by a reduction of the surface area per population equivalent, which decreased to 1.5m(2)/PE.

  20. Evaluation of design factors for a cascade aerator to enhance the efficiency of an oxidation pond for ferruginous mine drainage.

    PubMed

    Oh, Chamteut; Ji, Sangwoo; Cheong, Youngwook; Yim, Giljae; Hong, Ji-Hye

    2016-10-01

    This research focused on the optimum design of a cascade aerator to enhance the efficiency of an oxidation pond in a passive treatment system for remediating ferruginous mine drainage. For this purpose, various aeration experiments with aerators of different drop heights (0-4 m) and formations (types A and B) were executed on mine drainage. Type A simply drops the mine drainage into the oxidation pond while type B sprays the mine drainage and retains it for 8 min in each step. The efficiency enhancement of the oxidation pond was strongly dependent on the increase in pH and DO of the mine drainage discharged into the pond. The water quality improved with the increase in drop height but especially showed better effect with type B. The reasons for this result were attributed to the increase of contact surface and retention time of the mine drainage. The cascade aerator, therefore, should be designed to be as high as possible with the assistance of spraying form and retention time of the mine drainage to maximize the efficiency of the oxidation pond. These effects could be evaluated by calculating required areas of the oxidation pond for 95% of Fe(2+) oxidation. PMID:26936197

  1. Root aeration improves growth and nitrogen accumulation in rice seedlings under low nitrogen.

    PubMed

    Zhu, Jingwen; Liang, Jing; Xu, Zhihui; Fan, Xiaorong; Zhou, Quansuo; Shen, Qirong; Xu, Guohua

    2015-11-16

    In wetland soils, changes in oxygen (O2) level in the rhizosphere are believed to influence the behaviour of nutrients and their usage by plants. However, the effect of aeration on nitrogen (N) acquisition under different N supply conditions remains largely unknown. In this study, the rice cultivars Yangdao 6 (YD6, with higher root aerenchyma abundance) and Nongken 57 (NK57, with lower root aerenchyma abundance) were used to evaluate the effects of aeration on rice growth and N accumulation. Our results showed that the number of adventitious roots and the root surface area increased significantly, and ethylene production and aerenchyma formation decreased in both cultivars after external aeration (EA). Five N treatments, including no N (-N), 0.125 mM NH4NO3 (LN), 1.25 mM Ca(NO3)2 (NO3-N), 1.25 mM (NH4)2SO4 (NH4-N) and 1.25 mM NH4NO3 (N/N), were applied to YD6 and NK57 for 2 days under internal aeration or EA conditions. External aeration increased the root biomass in both cultivars and the shoot biomass in NK57 by 18-50 %. The total N concentrations in roots of YD6 grown under -N and LN and of NK57 grown under NO3-N were increased by EA. Expression of OsPAD4, one of four putative genes regulating aerenchyma formation, showed a similar pattern alongside changes in the ethylene level in the EA-treated rice irrespective of the N treatments. Furthermore, expression of the high-affinity nitrate transporter gene OsNRT2.1 was increased by EA under -N, LN and NO3-N conditions. Our data provide evidence of an interaction between O2 and the supply of N in ethylene production, aerenchyma formation and N nutrition through modification of the expression of OsPAD4 and OsNRT2.1.

  2. Root aeration improves growth and nitrogen accumulation in rice seedlings under low nitrogen

    PubMed Central

    Zhu, Jingwen; Liang, Jing; Xu, Zhihui; Fan, Xiaorong; Zhou, Quansuo; Shen, Qirong; Xu, Guohua

    2015-01-01

    In wetland soils, changes in oxygen (O2) level in the rhizosphere are believed to influence the behaviour of nutrients and their usage by plants. However, the effect of aeration on nitrogen (N) acquisition under different N supply conditions remains largely unknown. In this study, the rice cultivars Yangdao 6 (YD6, with higher root aerenchyma abundance) and Nongken 57 (NK57, with lower root aerenchyma abundance) were used to evaluate the effects of aeration on rice growth and N accumulation. Our results showed that the number of adventitious roots and the root surface area increased significantly, and ethylene production and aerenchyma formation decreased in both cultivars after external aeration (EA). Five N treatments, including no N (−N), 0.125 mM NH4NO3 (LN), 1.25 mM Ca(NO3)2 (NO3-N), 1.25 mM (NH4)2SO4 (NH4-N) and 1.25 mM NH4NO3 (N/N), were applied to YD6 and NK57 for 2 days under internal aeration or EA conditions. External aeration increased the root biomass in both cultivars and the shoot biomass in NK57 by 18–50 %. The total N concentrations in roots of YD6 grown under −N and LN and of NK57 grown under NO3-N were increased by EA. Expression of OsPAD4, one of four putative genes regulating aerenchyma formation, showed a similar pattern alongside changes in the ethylene level in the EA-treated rice irrespective of the N treatments. Furthermore, expression of the high-affinity nitrate transporter gene OsNRT2.1 was increased by EA under −N, LN and NO3-N conditions. Our data provide evidence of an interaction between O2 and the supply of N in ethylene production, aerenchyma formation and N nutrition through modification of the expression of OsPAD4 and OsNRT2.1. PMID:26578743

  3. Predicting oxygen transfer of fine bubble diffused aeration systems--model issued from dimensional analysis.

    PubMed

    Gillot, S; Capela-Marsal, S; Roustan, M; Héduit, A

    2005-04-01

    The standard oxygenation performances of fine bubble diffused aeration systems in clean water, measured in 12 cylindrical tanks (water depth from 2.4 to 6.1m), were analysed using dimensional analysis. A relationship was established to estimate the scale-up factor for oxygen transfer, the transfer number (N(T)) The transfer number, which is written as a function of the oxygen transfer coefficient (k(L)a(20)), the gas superficial velocity (U(G)), the kinematic viscosity of water (nu) and the acceleration due to gravity (g), has the same physical meaning as the specific oxygen transfer efficiency. N(T) only depends on the geometry of the tank/aeration system [the total surface of the perforated membrane (S(p)), the surface of the tank (S) or its diameter (D), the total surface of the zones covered by the diffusers ("aerated area", S(a)) and the submergence of the diffusers (h)]. This analysis allowed to better describe the mass transfer in cylindrical tanks. Within the range of the parameters considered, the oxygen transfer coefficient (k(L)a(20)) is an increasing linear function of the air flow rate. For a given air flow rate and a given tank surface area, k(L)a(20) decreases with the water depth (submergence of the diffusers). For a given water depth, k(L)a(20) increases with the number of diffusers, and, for an equal number of diffusers, with the total area of the zones covered by the diffusers. The latter result evidences the superiority of the total floor coverage over an arrangement whereby the diffusers are placed on separate grids. The specific standard oxygen transfer efficiency is independent of the air flow rate and the water depth, the drop in the k(L)a(20) being offset by the increase of the saturation concentration. For a given tank area, the impact of the total surface of the perforated membrane (S(p)) and of the aerated area (S(a)) is the same as on the oxygen transfer coefficient. PMID:15862338

  4. Control of a mechanical aeration process via topological sensitivity analysis

    NASA Astrophysics Data System (ADS)

    Abdelwahed, M.; Hassine, M.; Masmoudi, M.

    2009-06-01

    The topological sensitivity analysis method gives the variation of a criterion with respect to the creation of a small hole in the domain. In this paper, we use this method to control the mechanical aeration process in eutrophic lakes. A simplified model based on incompressible Navier-Stokes equations is used, only considering the liquid phase, which is the dominant one. The injected air is taken into account through local boundary conditions for the velocity, on the injector holes. A 3D numerical simulation of the aeration effects is proposed using a mixed finite element method. In order to generate the best motion in the fluid for aeration purposes, the optimization of the injector location is considered. The main idea is to carry out topological sensitivity analysis with respect to the insertion of an injector. Finally, a topological optimization algorithm is proposed and some numerical results, showing the efficiency of our approach, are presented.

  5. Aspects concerning the quality of aeration for environmental friendly turbines

    NASA Astrophysics Data System (ADS)

    Bunea, F.; Houde, S.; Ciocan, G. D.; Oprina, G.; Baran, G.; Pincovschi, I.

    2010-08-01

    The hydro renewable energy provides a reliable power source; it does not pollute the air or land but affects the aquatic habitat due to low dissolved oxygen (DO) level in the water discharged from turbines. Hydro-turbines intake generally withdraws water from the bottom layer of the reservoirs with low DO level. In the different methods used for improving DO downstream the hydropower plants the volume of air is considered to be the main parameter of the injection. The energetic consumption is affected, in terms of loss of turbine efficiency due to air injection. The authors propose a study to show the importance of the quality of air injection, meaning bubble size, pressure loss on the aeration device etc. Different types of fine bubble aeration systems have been tested and compared. The capacity to predict the aeration by numerical simulation is analysed.

  6. A 79-Year-Old Man With Interstitial Lung Disease and Cryptic Area of High 18 Fluorodeoxyglucose Uptake in Left Upper Lobe.

    PubMed

    Rapicetta, Cristian; Lococo, Filippo; Carbonelli, Cristiano; Sverzellati, Nicola; Di Paolo, Maria Liberata; Cavazza, Alberto; Serra, Silvia; Ricchetti, Tommaso; Gasparini, Elisa; Cesario, Alfredo; Sgarbi, Giorgio; Brandi, Loris; Paci, Massimiliano

    2015-12-01

    Seven years after left hemicolectomy and radical lymph nodal dissection followed by adjuvant chemotherapy for colorectal cancer (histotype, adenocarcinoma; stage, pT3N2M0; grading, G2), a slight increase in carcinoembryonic antigen levels (6.2 ng/mL; range, 0-5 ng/mL) was detected in a 79-year-old man. He was a heavy smoker with history of an interstitial fibrotic lung disease with associated areas of emphysema. PMID:26621296

  7. Particle-induced oxidative damage of indoor PM10 from coal burning homes in the lung cancer area of Xuan Wei, China

    NASA Astrophysics Data System (ADS)

    Shao, Longyi; Hu, Ying; Wang, Jing; Hou, Cong; Yang, Yuanyuan; Wu, Mingyuan

    2013-10-01

    The lung cancer mortality rate in the rural area of the Xuan Wei, Yunnan, is among the highest in China, especially in women. In this paper, the coal-burning indoor and corresponding outdoor PM10 samples were collected at the Hutou village, representing the case of high lung cancer rate, and the Xize village, representing the case of low lung cancer rate. Plasmid scission assay was used to investigate the bioreactivity of the PM10. The inductively coupled plasma-mass spectrometry (ICP-MS) was employed to investigate the trace element compositions of the PM10. The results showed that the oxidative damage caused by both indoor and outdoor PM10 at the Hutou village was obviously higher than that at the Xize village, with the indoor PM10 having higher oxidative damage than corresponding outdoors. Among all analyzed samples, the indoor night PM10 samples from the Hutou village have the highest oxidative capacity. The levels of total water-soluble elements had a higher level in the PM10 of the Hutou village than that of the Xize village. It is interesting that the levels of water-soluble As, Cd, Cs, Pb, Sb, Tl and Zn in PM10 had better positive correlation with DNA damage rates, implying that these elements in their water-soluble state should be one of the main factors responsible for the high oxidative capacity of PM10, thus possibly the higher lung cancer rates, at the Hutou village.

  8. Fault detection and isolation of sensors in aeration control systems.

    PubMed

    Carlsson, Bengt; Zambrano, Jesús

    2016-01-01

    In this paper, we consider the problem of fault detection (FD) and isolation in the aeration system of an activated sludge process. For this study, the dissolved oxygen in each aerated zone is assumed to be controlled automatically. As the basis for an FD method we use the ratio of air flow rates into different zones. The method is evaluated in two scenarios: using the Benchmark Simulation Model no. 1 (BSM1) by Monte Carlo simulations and using data from a wastewater treatment plant. The FD method shows good results for a correct and early FD and isolation.

  9. Retrofitting activated sludge systems to intermittent aeration for nitrogen removal.

    PubMed

    Hanhan, O; Artan, N; Orhon, D

    2002-01-01

    The paper provides the basis and the conceptual approach of applying process kinetics and modelling to the design of alternating activated sludge systems for retrofitting existing activated sludge plants to intermittent aeration for nitrogen removal. It shows the significant role of the two specific parameters, namely, the aerated fraction and the cycle time ratio on process performance through model simulations and proposes a way to incorporate them into a design procedure using process stoichiometry and mass balance. It illustrates the effect of these parameters, together with the sludge age, in establishing the balance between the denitrification potential and the available nitrogen created in the anoxic/aerobic sequences of system operation.

  10. Retrofitting activated sludge systems to intermittent aeration for nitrogen removal.

    PubMed

    Hanhan, O; Artan, N; Orhon, D

    2002-01-01

    The paper provides the basis and the conceptual approach of applying process kinetics and modelling to the design of alternating activated sludge systems for retrofitting existing activated sludge plants to intermittent aeration for nitrogen removal. It shows the significant role of the two specific parameters, namely, the aerated fraction and the cycle time ratio on process performance through model simulations and proposes a way to incorporate them into a design procedure using process stoichiometry and mass balance. It illustrates the effect of these parameters, together with the sludge age, in establishing the balance between the denitrification potential and the available nitrogen created in the anoxic/aerobic sequences of system operation. PMID:12420968

  11. Regional Inequalities in Lung Cancer Mortality in Belgium at the Beginning of the 21st Century: The Contribution of Individual and Area-Level Socioeconomic Status and Industrial Exposure.

    PubMed

    Hagedoorn, Paulien; Vandenheede, Hadewijch; Willaert, Didier; Vanthomme, Katrien; Gadeyne, Sylvie

    2016-01-01

    Being a highly industrialized country with one of the highest male lung cancer mortality rates in Europe, Belgium is an interesting study area for lung cancer research. This study investigates geographical patterns in lung cancer mortality in Belgium. More specifically it probes into the contribution of individual as well as area-level characteristics to (sub-district patterns in) lung cancer mortality. Data from the 2001 census linked to register data from 2001-2011 are used, selecting all Belgian inhabitants aged 65+ at time of the census. Individual characteristics include education, housing status and home ownership. Urbanicity, unemployment rate, the percentage employed in mining and the percentage employed in other high-risk industries are included as sub-district characteristics. Regional variation in lung cancer mortality at sub-district level is estimated using directly age-standardized mortality rates. The association between lung cancer mortality and individual and area characteristics, and their impact on the variation of sub-district level is estimated using multilevel Poisson models. Significant sub-district variations in lung cancer mortality are observed. Individual characteristics explain a small share of this variation, while a large share is explained by sub-district characteristics. Individuals with a low socioeconomic status experience a higher lung cancer mortality risk. Among women, an association with lung cancer mortality is found for the sub-district characteristics urbanicity and unemployment rate, while for men lung cancer mortality was associated with the percentage employed in mining. Not just individual characteristics, but also area characteristics are thus important determinants of (regional differences in) lung cancer mortality.

  12. Regional Inequalities in Lung Cancer Mortality in Belgium at the Beginning of the 21st Century: The Contribution of Individual and Area-Level Socioeconomic Status and Industrial Exposure.

    PubMed

    Hagedoorn, Paulien; Vandenheede, Hadewijch; Willaert, Didier; Vanthomme, Katrien; Gadeyne, Sylvie

    2016-01-01

    Being a highly industrialized country with one of the highest male lung cancer mortality rates in Europe, Belgium is an interesting study area for lung cancer research. This study investigates geographical patterns in lung cancer mortality in Belgium. More specifically it probes into the contribution of individual as well as area-level characteristics to (sub-district patterns in) lung cancer mortality. Data from the 2001 census linked to register data from 2001-2011 are used, selecting all Belgian inhabitants aged 65+ at time of the census. Individual characteristics include education, housing status and home ownership. Urbanicity, unemployment rate, the percentage employed in mining and the percentage employed in other high-risk industries are included as sub-district characteristics. Regional variation in lung cancer mortality at sub-district level is estimated using directly age-standardized mortality rates. The association between lung cancer mortality and individual and area characteristics, and their impact on the variation of sub-district level is estimated using multilevel Poisson models. Significant sub-district variations in lung cancer mortality are observed. Individual characteristics explain a small share of this variation, while a large share is explained by sub-district characteristics. Individuals with a low socioeconomic status experience a higher lung cancer mortality risk. Among women, an association with lung cancer mortality is found for the sub-district characteristics urbanicity and unemployment rate, while for men lung cancer mortality was associated with the percentage employed in mining. Not just individual characteristics, but also area characteristics are thus important determinants of (regional differences in) lung cancer mortality. PMID:26760040

  13. Regional Inequalities in Lung Cancer Mortality in Belgium at the Beginning of the 21st Century: The Contribution of Individual and Area-Level Socioeconomic Status and Industrial Exposure

    PubMed Central

    Hagedoorn, Paulien; Vandenheede, Hadewijch; Willaert, Didier; Vanthomme, Katrien; Gadeyne, Sylvie

    2016-01-01

    Being a highly industrialized country with one of the highest male lung cancer mortality rates in Europe, Belgium is an interesting study area for lung cancer research. This study investigates geographical patterns in lung cancer mortality in Belgium. More specifically it probes into the contribution of individual as well as area-level characteristics to (sub-district patterns in) lung cancer mortality. Data from the 2001 census linked to register data from 2001–2011 are used, selecting all Belgian inhabitants aged 65+ at time of the census. Individual characteristics include education, housing status and home ownership. Urbanicity, unemployment rate, the percentage employed in mining and the percentage employed in other high-risk industries are included as sub-district characteristics. Regional variation in lung cancer mortality at sub-district level is estimated using directly age-standardized mortality rates. The association between lung cancer mortality and individual and area characteristics, and their impact on the variation of sub-district level is estimated using multilevel Poisson models. Significant sub-district variations in lung cancer mortality are observed. Individual characteristics explain a small share of this variation, while a large share is explained by sub-district characteristics. Individuals with a low socioeconomic status experience a higher lung cancer mortality risk. Among women, an association with lung cancer mortality is found for the sub-district characteristics urbanicity and unemployment rate, while for men lung cancer mortality was associated with the percentage employed in mining. Not just individual characteristics, but also area characteristics are thus important determinants of (regional differences in) lung cancer mortality. PMID:26760040

  14. Base excision repair genes and risk of lung cancer among San Francisco Bay Area Latinos and African-Americans

    PubMed Central

    Chang, Jeffrey S.; Wrensch, Margaret R.; Hansen, Helen M.; Sison, Jennette D.; Aldrich, Melinda C.; Quesenberry, Charles P.; Seldin, Michael F.; Kelsey, Karl T.; Wiencke, John K.

    2009-01-01

    Base excision repair (BER) is the primary DNA damage repair mechanism for repairing small base lesions resulting from oxidation and alkylation damage. This study examines the association between 24 single-nucleotide polymorphisms (SNPs) belonging to five BER genes (XRCC1, APEX1, PARP1, MUTYH and OGG1) and lung cancer among Latinos (113 cases and 299 controls) and African-Americans (255 cases and 280 controls). The goal was to evaluate the differences in genetic contribution to lung cancer risk by ethnic groups. Analyses of individual SNPs and haplotypes were performed using unconditional logistic regressions adjusted for age, sex and genetic ancestry. Four SNPs among Latinos and one SNP among African-Americans were significantly (P < 0.05) associated with either risk of all lung cancer or non-small cell lung cancer (NSCLC). However, only the association between XRCC1 Arg399Gln (rs25487) and NSCLC among Latinos (odds ratio associated with every copy of Gln = 1.52; 95% confidence interval: 1.01–2.28) had a false-positive report probability of <0.5. Arg399Gln is a SNP with some functional evidence and has been shown previously to be an important SNP associated with lung cancer, mostly for Asians. Since the analyses were adjusted for genetic ancestry, the observed association between Arg399Gln and NSCLC among Latinos is unlikely to be confounded by population stratification; however, this result needs to be confirmed by additional studies among the Latino population. This study suggests that there are genetic differences in the association between BER pathway and lung cancer between Latinos and African-Americans. PMID:19029194

  15. Effect of cyclic aeration on fouling in submerged membrane bioreactor for wastewater treatment.

    PubMed

    Wu, Jun; He, Chengda

    2012-07-01

    Due to the inefficiency of aeration measures in preventing fouling by soluble and colloidal particles. The effect of alternating high/low cyclic aeration mode on the membrane fouling in the submerged membrane bioreactor was studied by comparing to fouling in a constant aeration mode. Results indicated a higher overall fouling rate in the cyclic aeration mode than in the constant aeration. However, a higher percentage of reversible fouling was observed for the cyclic aeration mode. The membrane permeability can be more easily recovered from physical cleaning such as backwashing in the cyclic aeration mode. The activated sludge floc size distribution analysis revealed a floc destruction and re-flocculation processes caused by the alternating high/low aeration. The short high aeration period could prevent the destruction of strong strength bonds within activated sludge flocs. Therefore, less soluble and colloidal material was observed in the supernatant due to the preservation of the strong strength bonds. The weak strength bonds damaged in the high aeration period could be recovered in the re-flocculation process in the low aeration period. The floc destruction and re-flocculation processes were suggested to be the main reason for the low irreversible fouling in the cyclic aeration mode.

  16. Intermittent aeration to improve wastewater treatment efficiency in pilot-scale constructed wetland.

    PubMed

    Uggetti, Enrica; Hughes-Riley, Theodore; Morris, Robert H; Newton, Michael I; Trabi, Christophe L; Hawes, Patrick; Puigagut, Jaume; García, Joan

    2016-07-15

    Forced aeration of horizontal subsurface flow constructed wetlands (HSSF CWs) is nowadays a recognized method to improve treatment efficiency, mainly in terms of ammonium removal. While numerous investigations have been reported testing constant aeration, scarce information can be found about the efficiency of intermittent aeration. This study aims at comparing continuous and intermittent aeration, establishing if there is an optimal regime that will increase treatment efficiency of HSSF CWs whilst minimizing the energy requirement. Full and intermittent aeration were tested in a pilot plant of three HSSF CWs (2.64m(2) each) fed with primary treated wastewater. One unit was fully aerated; one intermittently aerated (i.e. by setting a limit of 0.5mg/L dissolved oxygen within the bed) with the remaining unit not aerated as a control. Results indicated that intermittent aeration was the most successful operating method. Indeed, the coexistence of aerobic and anoxic conditions promoted by the intermittent aeration resulted in the highest COD (66%), ammonium (99%) and total nitrogen (79%) removals. On the other hand, continuous aeration promotes ammonium removal (99%), but resulted in nitrate concentrations in the effluent of up to 27mg/L. This study demonstrates the high potential of the intermittent aeration to increase wastewater treatment efficiency of CWs providing an extreme benefit in terms of the energy consumption.

  17. Dissolved Oxygen management in catfish ponds using electric paddlewheel aerators: new approaches with old technology

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The electric paddlewheel aerator has been the main aerator used in the U.S. catfish industry for the post forty years. While it has its limitations, it is perhaps the most efficient shallow-water aerator yet to be developed. Its shortcomings result not so much from poor design, as from poor usage. U...

  18. 5. AERATOR VIEW FROM DOWNSTREAM. FLUSH VALVE AT RIGHT OPENS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. AERATOR VIEW FROM DOWNSTREAM. FLUSH VALVE AT RIGHT OPENS TO CLEAR THE SYSTEM ABOVE THE SILT AND DEBRIS AND TO STOP THE FLOW OF WATER INTO THE SYSTEM DOWN LINE. BOX FLUME CONTINUES DOWN LINE TO SEDIMENTATION CHAMBER. - Kalaupapa Water Supply System, Waikolu Valley to Kalaupapa Settlement, Island of Molokai, Kalaupapa, Kalawao County, HI

  19. 21 CFR 880.6100 - Ethylene oxide gas aerator cabinet.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ethylene oxide gas aerator cabinet. 880.6100 Section 880.6100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... with a ventilation system designed to circulate and exchange the air in the cabinet to shorten the...

  20. Non-autoclaved aerated concrete with mineral additives

    NASA Astrophysics Data System (ADS)

    Il'ina, L. V.; Rakov, M. A.

    2016-01-01

    We investigated the effect of joint grinding of Portland cement clinker, silica and carbonate components and mineral additives to specific surface of 280 - 300 m2/kg on the properties (strength, average density and thermal conductivity) of non-autoclaved aerated concrete, and the porosity of the hardened cement paste produced from Portland cement clinker with mineral additives. The joint grinding of the Portland cement clinker with silica and carbonate components and mineral additives reduces the energy consumption of non-autoclaved aerated concrete production. The efficiency of mineral additives (diopside, wollastonite) is due to the closeness the composition, the type of chemical bonds, physical and chemical characteristics (specific enthalpy of formation, specific entropy) to anhydrous clinker minerals and their hydration products. Considering the influence of these additions on hydration of clinker minerals and formation of hardened cement paste structure, dispersed wollastonite and diopside should be used as mineral additives. The hardness and, consequently, the elastic modulus of diopside are higher than that of hardened cement paste. As a result, there is a redistribution of stresses in the hardened cement paste interporous partitions and hardening, both the partitions and aerated concrete on the whole. The mineral additives introduction allowed to obtain the non-autoclaved aerated concrete with average density 580 kg/m3, compressive strength of 3.3 MPa and thermal conductivity of 0.131 W/(m.°C).

  1. Aerated Lagoons. Instructor's Guide. Biological Treatment Process Control.

    ERIC Educational Resources Information Center

    Andersen, Lorri

    This unit (which consists of a single lesson) describes the structural and operationally unique features of aerated lagoons. In addition, special troubleshooting and maintenance problems are discussed. The instructor's guide for the unit includes: (1) an overview of the lesson; (2) lesson plan; (3) lecture outline (keyed to a set of slides used…

  2. 4. AERATOR AT 525, CONSTRUCTED 19371938, VIEW FROM UPSTREAM (TRASH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. AERATOR AT 525, CONSTRUCTED 1937-1938, VIEW FROM UPSTREAM (TRASH SCREEN REMOVED FOR CLARITY), WATER FROM INTAKE FLOWS THROUGH FLUME, THEN DAMS, AND SPILLS OVER STEPS TO MIX WITH OXYGEN, THUS REDUCING ACIDITY LEVELS. ACID INDUCES FASTER CORROSION OF PIPES AND SPOILS TASTE. - Kalaupapa Water Supply System, Waikolu Valley to Kalaupapa Settlement, Island of Molokai, Kalaupapa, Kalawao County, HI

  3. 6. AERATOR VIEWED UPSTREAM. DETAIL OF FLUSH VALVE AND VIEW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. AERATOR VIEWED UPSTREAM. DETAIL OF FLUSH VALVE AND VIEW INTO BOX FLUME. NOTE WRENCH TO OPEN VALVE AND REMAINS OF OLD SHOVEL USED FOR MAINTENANCE. TRASH SCREEN MESH IS SEEN AT BOTTOM LEFT. - Kalaupapa Water Supply System, Waikolu Valley to Kalaupapa Settlement, Island of Molokai, Kalaupapa, Kalawao County, HI

  4. The "baby lung" became an adult.

    PubMed

    Gattinoni, Luciano; Marini, John J; Pesenti, Antonio; Quintel, Michael; Mancebo, Jordi; Brochard, Laurent

    2016-05-01

    The baby lung was originally defined as the fraction of lung parenchyma that, in acute respiratory distress syndrome (ARDS), still maintains normal inflation. Its size obviously depends on ARDS severity and relates to the compliance of the respiratory system. CO2 clearance and blood oxygenation primarily occur within the baby lung. While the specific compliance suggests the intrinsic mechanical characteristics to be nearly normal, evidence from positron emission tomography suggests that at least a part of the well-aerated baby lung is inflamed. The baby lung is more a functional concept than an anatomical one; in fact, in the prone position, the baby lung "shifts" from the ventral lung regions toward the dorsal lung regions while usually increasing its size. This change is associated with better gas exchange, more homogeneously distributed trans-pulmonary forces, and a survival advantage. Positive end expiratory pressure also increases the baby lung size, both allowing better inflation of already open units and adding new pulmonary units. Viewed as surrogates of stress and strain, tidal volume and plateau pressures are better tailored to baby lung size than to ideal body weight. Although less information is available for the baby lung during spontaneous breathing efforts, the general principles regulating the safety of ventilation are also applicable under these conditions. PMID:26781952

  5. The potential for aeration of MSW landfills to accelerate completion

    SciTech Connect

    Rich, Charlotte; Gronow, Jan; Voulvoulis, Nikolaos

    2008-07-01

    Landfilling is a popular waste disposal method, but, as it is practised currently, it is fundamentally unsustainable. The low short-term financial costs belie the potential long-term environmental costs, and traditional landfill sites require long-term management in order to mitigate any possible environmental damage. Old landfill sites might require aftercare for decades or even centuries, and in some cases remediation may be necessary. Biological stabilisation of a landfill is the key issue; completion criteria provide a yardstick by which the success of any new technology may be measured. In order for a site to achieve completion it must pose no risk to human health or the environment, meaning that attenuation of any emissions from the site must occur within the local environment without causing harm. Remediation of old landfill sites by aerating the waste has been undertaken in Germany, the United States, Italy and The Netherlands, with considerable success. At a pilot scale, aeration has also been used in newly emplaced waste to accelerate stabilisation. This paper reviews the use of aerobic landfill worldwide, and assesses the ways in which the use of aerobic landfill techniques can decrease the risks associated with current landfill practices, making landfill a more sustainable waste disposal option. It focuses on assessing ways to utilise aeration to enhance stabilisation. The results demonstrated that aeration of old landfill sites may be an efficient and cost-effective method of remediation and allow the date of completion to be brought forward by decades. Similarly, aeration of newly emplaced waste can be effective in enhancing degradation, assisting with completion and reducing environmental risks. However, further research is required to establish what procedure for adding air to a landfill would be most suitable for the UK and to investigate new risks that may arise, such as the possible emission of non-methane organic compounds.

  6. Numerical simulation of aeration bubble growth in a plug-flow aeration tank used in wastewater treatment

    NASA Astrophysics Data System (ADS)

    Wang, H. R.; Li, Y. P.

    2010-03-01

    The micro-scale hydrodynamics of bubbles growth by aeration is related to the oxygen transfer efficiency and the overall performance of the activated sludge wastewater treatment process. To gain a deeper insight on the micro-scale phenomena of dispersed bubble in this process, a three-dimensional direct simulation method is developed to study the effects of the liquid cross-flow on micro-scale behavior of bubble growth in a plug-flow aeration tank. The numerical simulations are performed using the level set method coupling with the governing equations of a single fluid with variable properties. The governing equations are solved using the finite-volume projection technique. The simulation results are compared with the experimental observations and theoretical relations. The simulated results show that water cross-flow in plug-flow type aeration tank has a strong impact on the bubble growth process. Compared to that generated under quiescent water conditions used in mixing type aeration tank, the bubble under water cross-flow conditions grows downstream along the tilted axis, and the bubble generation time tends to decrease noticeably and the bubble at detachment has significantly smaller size. The dynamic characteristics of the bubble growth through two orifices are also numerically studied. The effect of water cross-flow on the bubbling synchronicity is finally discussed.

  7. Effect of spray aeration on organics and nitrogen removal in vertical subsurface flow constructed wetland.

    PubMed

    Ding, Yi; Wang, Wei; Song, Xin-Shan; Wang, Gang; Wang, Yu-Hui

    2014-12-01

    The objective of present study was to assess the simultaneous removal of organics and nitrogen by four lab-scale vertical subsurface flow constructed wetlands (V-SFCWs). The emergent plants employed were Canna indica. Five-month experiments showed that the planted and aerated system largely reduced the COD by 95%, NH4 by 88% and total inorganic nitrogen (TIN) by 83%. It outperformed the unplanted or simple aerated system and was much better than non-aerated system. The study provided a strong evidence to support widespread research and application of spray aeration as a low-cost and energy-efficient aeration technology in V-SFCWs. PMID:25259785

  8. Effect of spray aeration on organics and nitrogen removal in vertical subsurface flow constructed wetland.

    PubMed

    Ding, Yi; Wang, Wei; Song, Xin-Shan; Wang, Gang; Wang, Yu-Hui

    2014-12-01

    The objective of present study was to assess the simultaneous removal of organics and nitrogen by four lab-scale vertical subsurface flow constructed wetlands (V-SFCWs). The emergent plants employed were Canna indica. Five-month experiments showed that the planted and aerated system largely reduced the COD by 95%, NH4 by 88% and total inorganic nitrogen (TIN) by 83%. It outperformed the unplanted or simple aerated system and was much better than non-aerated system. The study provided a strong evidence to support widespread research and application of spray aeration as a low-cost and energy-efficient aeration technology in V-SFCWs.

  9. Liquid and atmospheric ammonia concentrations from a dairy lagoon during an aeration experiment

    NASA Astrophysics Data System (ADS)

    Rumburg, Brian; Neger, Manjit; Mount, George H.; Yonge, David; Filipy, Jenny; Swain, John; Kincaid, Ron; Johnson, Kristen

    Ammonia emissions from agriculture are an environmental and human health concern, and there is increasing pressure to reduce emissions. Animal agriculture is the largest global source of ammonia emissions and on a per cow basis dairy operations are the largest emitters. The storage and disposal of the dairy waste is one area where emissions can be reduced, aerobic biological treatment of wastewater being a common and effective way of reducing ammonia emissions. An aeration experiment in a dairy lagoon with two commercial aerators was performed for 1 month. Liquid concentrations of ammonia, total nitrogen, nitrite and nitrate were monitored before, during and after the experiment and atmospheric ammonia was measured downwind of the lagoon using a short-path differential optical absorption spectroscopy (DOAS) instrument with 1 ppbv sensitivity. No changes in either liquid or atmospheric ammonia concentrations were detected throughout the experiment, and neither dissolved oxygen, nitrite nor nitrate could be detected in the lagoon at any time. The average ammonia concentration at 10 sampling sites in the lagoon at a depth of 0.15 m was 650 mg l -1 and at 0.90 m it was 700 mg l -1 NH 3-N. The average atmospheric ammonia concentration 50 m downwind was about 300 ppbv. The 0.90 m depth total nitrogen concentrations and total and volatile solids concentrations decreased during the experiment due to some mixing of the lagoon but the 0.15 m depth concentrations did not decrease indicating that the aerators were not strong enough to mix the sludge off the bottom into the whole water column.

  10. Redox potential driven aeration during very-high-gravity ethanol fermentation by using flocculating yeast

    PubMed Central

    Liu, Chen-Guang; Hao, Xue-Mi; Lin, Yen-Han; Bai, Feng-Wu

    2016-01-01

    Ethanol fermentation requires oxygen to maintain high biomass and cell viability, especially under very-high-gravity (VHG) condition. In this work, fermentation redox potential (ORP) was applied to drive the aeration process at low dissolved oxygen (DO) levels, which is infeasible to be regulated by a DO sensor. The performance and characteristics of flocculating yeast grown under 300 and 260 g glucose/L conditions were subjected to various aeration strategies including: no aeration; controlled aeration at −150, −100 and −50 mV levels; and constant aeration at 0.05 and 0.2 vvm. The results showed that anaerobic fermentation produced the least ethanol and had the highest residual glucose after 72 h of fermentation. Controlled aerations, depending on the real-time oxygen demand, led to higher cell viability than the no-aeration counterpart. Constant aeration triggered a quick biomass formation, and fast glucose utilization. However, over aeration at 0.2 vvm caused a reduction of final ethanol concentration. The controlled aeration driven by ORP under VHG conditions resulted in the best fermentation performance. Moreover, the controlled aeration could enhance yeast flocculating activity, promote an increase of flocs size, and accelerate yeast separation near the end of fermentation. PMID:27161047

  11. Redox potential driven aeration during very-high-gravity ethanol fermentation by using flocculating yeast.

    PubMed

    Liu, Chen-Guang; Hao, Xue-Mi; Lin, Yen-Han; Bai, Feng-Wu

    2016-05-10

    Ethanol fermentation requires oxygen to maintain high biomass and cell viability, especially under very-high-gravity (VHG) condition. In this work, fermentation redox potential (ORP) was applied to drive the aeration process at low dissolved oxygen (DO) levels, which is infeasible to be regulated by a DO sensor. The performance and characteristics of flocculating yeast grown under 300 and 260 g glucose/L conditions were subjected to various aeration strategies including: no aeration; controlled aeration at -150, -100 and -50 mV levels; and constant aeration at 0.05 and 0.2 vvm. The results showed that anaerobic fermentation produced the least ethanol and had the highest residual glucose after 72 h of fermentation. Controlled aerations, depending on the real-time oxygen demand, led to higher cell viability than the no-aeration counterpart. Constant aeration triggered a quick biomass formation, and fast glucose utilization. However, over aeration at 0.2 vvm caused a reduction of final ethanol concentration. The controlled aeration driven by ORP under VHG conditions resulted in the best fermentation performance. Moreover, the controlled aeration could enhance yeast flocculating activity, promote an increase of flocs size, and accelerate yeast separation near the end of fermentation.

  12. Redox potential driven aeration during very-high-gravity ethanol fermentation by using flocculating yeast.

    PubMed

    Liu, Chen-Guang; Hao, Xue-Mi; Lin, Yen-Han; Bai, Feng-Wu

    2016-01-01

    Ethanol fermentation requires oxygen to maintain high biomass and cell viability, especially under very-high-gravity (VHG) condition. In this work, fermentation redox potential (ORP) was applied to drive the aeration process at low dissolved oxygen (DO) levels, which is infeasible to be regulated by a DO sensor. The performance and characteristics of flocculating yeast grown under 300 and 260 g glucose/L conditions were subjected to various aeration strategies including: no aeration; controlled aeration at -150, -100 and -50 mV levels; and constant aeration at 0.05 and 0.2 vvm. The results showed that anaerobic fermentation produced the least ethanol and had the highest residual glucose after 72 h of fermentation. Controlled aerations, depending on the real-time oxygen demand, led to higher cell viability than the no-aeration counterpart. Constant aeration triggered a quick biomass formation, and fast glucose utilization. However, over aeration at 0.2 vvm caused a reduction of final ethanol concentration. The controlled aeration driven by ORP under VHG conditions resulted in the best fermentation performance. Moreover, the controlled aeration could enhance yeast flocculating activity, promote an increase of flocs size, and accelerate yeast separation near the end of fermentation. PMID:27161047

  13. Lung Emergencies

    MedlinePlus

    ... Emergencies Cardiac Emergencies Eye Emergencies Lung Emergencies Surgeries Lung Emergencies People with Marfan syndrome can be at ... should be considered an emergency. Symptoms of sudden lung collapse (pneumothorax) Symptoms of a sudden lung collapse ...

  14. Lung Cancer

    MedlinePlus

    ... version of this page please turn Javascript on. Lung Cancer What is Lung Cancer? How Tumors Form The body is made ... button on your keyboard.) Two Major Types of Lung Cancer There are two major types of lung ...

  15. Lung metastases

    MedlinePlus

    Metastases to the lung; Metastatic cancer to the lung ... Metastatic tumors in the lungs are cancers that developed at other places in the body (or other parts of the lungs) and spread through the ...

  16. Effective pine bark composting with the Dome Aeration Technology

    SciTech Connect

    Trois, Cristina . E-mail: troisc@ukzn.ac.za; Polster, Andreas

    2007-07-01

    In South Africa garden refuse is primarily disposed of in domestic landfills. Due to the large quantities generated, any form of treatment would be beneficial for volume reduction, waste stabilization and resource recovery. Dome Aeration Technology (DAT) is an advanced process for aerobic biological degradation of garden refuse and general waste [Paar, S., Brummack, J., Gemende, B., 1999a. Advantages of dome aeration in mechanical-biological waste treatment. In: Proceedings of the 7th International Waste Management and Landfill Symposium, Cagliari, 4-8 October 1999; Paar, S., Brummack, J., Gemende, B., 1999b. Mechanical-biological waste stabilization by the dome aeration method. Environment Protection Engineering 25 (3/99). Mollekopf, N., Brummack, J., Paar, S., Vorster, K., 2002. Use of the Dome Aeration Technology for biochemical stabilization of waste prior to landfilling. In: Proceedings of the Wastecon 2002, Waste Congress and Exhibition, Durban, South Africa.]. It is a non-reactor open windrow composting process, with the main advantage being that the input material needs no periodic turning. A rotting time of only 3-4 months indicates the high efficiency. Additionally, the low capital/operational costs, low energy inputs and limited plant requirements provide potential for use in aerobic refuse stabilization. The innovation in the DAT process is the passive aeration achieved by thermally driven advection through open windrows caused by temperature differences between the degrading material and the outside environment. This paper investigates the application of Dome Aeration Technology to pine bark composting as part of an integrated waste management strategy. A full-scale field experiment was performed at the Bisasar Road Landfill Site in Durban to assess the influence of climate, waste composition and operational conditions on the process. A test windrow was constructed and measurements of temperature and airflow through the material were taken. The process

  17. BIOVENTING - Groundwater Aeration by Discontinuous Oxygen Gas Pulse Injections

    NASA Astrophysics Data System (ADS)

    Schirmer, M.

    2003-12-01

    Groundwater aeration by discontinuous oxygen gas pulse injections appears to be a promising concept for enhanced natural attenuation of dissolved contaminants that are susceptible for oxygenase enzyme attacks. Oxygen amendments facilitate indigenous microbiota to catabolize groundwater pollutants, such as aromatics, that are considered to be recalcitrant in absence of dissolved oxygen. As a rule, natural attenuation of many pollutants under aerobic conditions is considerably faster than under anaerobic conditions. Thus, enhancing the dissolved oxygen level appears to be worthwhile. In situ aeration of groundwater has been accomplished by air sparging, H2O2-supply, or by utilization of oxygen release compounds. However, continuous aeration of previously anaerobic groundwater is not desirable for several reasons: (a) economic efforts too high, (b) pollutant dislocation towards surface (desired only in air sparging), (c) risk of aquifer clogging (gas clogging, oxidation of ferrous iron, formation of bioslimes). In contrast, discontinuous oxygen gas sparging provides only for periodical groundwater aeration which is followed by microaerobic and suboxic conditions. Microaerobic conditions can prevail spatially (e.g., at plume fringes or within biofilms) or temporarily (e.g., at discontinuous bioventing). They still allow adapted bacteria to transform environmental pollutants to less toxic compounds, e.g., aromatic ring cleavage after dioxygenasis attack. Ring cleavage products, on the other hand, may be degraded more easily by anaerobic consortia than the initial aromatic compounds, making oxygen depletion periods highly intriguing in regard to an initiation of natural attenuation processes at plume fringes. In our work we outline the effect of oxygen depletion conditions on biodegradation of monchlorobenzene (MCB) as they occur subsequently to temporary aeration periods. For microaerobic conditions, relative to the oxygen supply, a stoichiometric transformation of MCB

  18. Lung cancer

    SciTech Connect

    Aisner, J.

    1985-01-01

    This book contains 13 chapters. Some of the chapter titles are: The Pathology of Lung Cancer; Radiotherapy for Non-Small-Cell Cancer of the Lung; Chemotherapy for Non-Small-Cell Lung Cancer; Immunotherapy in the Management of Lung Cancer; Preoperative Staging and Surgery for Non-Small-Cell Lung Cancer; and Prognostic Factors in Lung Cancer.

  19. Detailed diesel exhaust characteristics including particle surface area and lung deposited dose for better understanding of health effects in human chamber exposure studies

    NASA Astrophysics Data System (ADS)

    Wierzbicka, Aneta; Nilsson, Patrik T.; Rissler, Jenny; Sallsten, Gerd; Xu, Yiyi; Pagels, Joakim H.; Albin, Maria; Österberg, Kai; Strandberg, Bo; Eriksson, Axel; Bohgard, Mats; Bergemalm-Rynell, Kerstin; Gudmundsson, Anders

    2014-04-01

    Several diesel exhaust (DE) characteristics, comprising both particle and gas phase, recognized as important when linking with health effects, are not reported in human chamber exposure studies. In order to understand effects of DE on humans there is a need for better characterization of DE when performing exposure studies. The aim of this study was to determine and quantify detailed DE characteristics during human chamber exposure. Additionally to compare to reported DE properties in conducted human exposures. A wide battery of particle and gas phase measurement techniques have been used to provide detailed DE characteristics including the DE particles (DEP) surface area, fraction and dose deposited in the lungs, chemical composition of both particle and gas phase such as NO, NO2, CO, CO2, volatile organic compounds (including aldehydes, benzene, toluene) and polycyclic aromatic hydrocarbons (PAHs). Eyes, nose and throat irritation effects were determined. Exposure conditions with PM1 (<1 μm) mass concentration 280 μg m-3, number concentration 4 × 105 cm-3 and elemental to total carbon fraction of 82% were generated from a diesel vehicle at idling. When estimating the lung deposited dose it was found that using the size dependent effective density (in contrast to assuming unity density) reduced the estimated respiratory dose by 132% by mass. Accounting for agglomerated structure of DEP prevented underestimation of lung deposited dose by surface area by 37% in comparison to assuming spherical particles. Comparison of DE characteristics reported in conducted chamber exposures showed that DE properties vary to a great extent under the same DEP mass concentration and engine load. This highlights the need for detailed and standardized approach for measuring and reporting of DE properties. Eyes irritation effects, most probably caused by aldehydes in the gas phase, as well as nose irritation were observed at exposure levels below current occupational exposure limit

  20. Sequentially aerated membrane biofilm reactors for autotrophic nitrogen removal: microbial community composition and dynamics

    PubMed Central

    Pellicer-Nàcher, Carles; Franck, Stéphanie; Gülay, Arda; Ruscalleda, Maël; Terada, Akihiko; Al-Soud, Waleed Abu; Hansen, Martin Asser; Sørensen, Søren J; Smets, Barth F

    2014-01-01

    Membrane-aerated biofilm reactors performing autotrophic nitrogen removal can be successfully applied to treat concentrated nitrogen streams. However, their process performance is seriously hampered by the growth of nitrite oxidizing bacteria (NOB). In this work we document how sequential aeration can bring the rapid and long-term suppression of NOB and the onset of the activity of anaerobic ammonium oxidizing bacteria (AnAOB). Real-time quantitative polymerase chain reaction analyses confirmed that such shift in performance was mirrored by a change in population densities, with a very drastic reduction of the NOB Nitrospira and Nitrobacter and a 10-fold increase in AnAOB numbers. The study of biofilm sections with relevant 16S rRNA fluorescent probes revealed strongly stratified biofilm structures fostering aerobic ammonium oxidizing bacteria (AOB) in biofilm areas close to the membrane surface (rich in oxygen) and AnAOB in regions neighbouring the liquid phase. Both communities were separated by a transition region potentially populated by denitrifying heterotrophic bacteria. AOB and AnAOB bacterial groups were more abundant and diverse than NOB, and dominated by the r-strategists Nitrosomonas europaea and Ca. Brocadia anammoxidans, respectively. Taken together, the present work presents tools to better engineer, monitor and control the microbial communities that support robust, sustainable and efficient nitrogen removal. PMID:24112350

  1. Soil aeration status in a lowland wet grassland

    NASA Astrophysics Data System (ADS)

    Barber, K. R.; Leeds-Harrison, P. B.; Lawson, C. S.; Gowing, D. J. G.

    2004-02-01

    The maintenance or development of plant community diversity in species-rich wet grasslands has been a focus of water management considerations in the UK for the past 20 years. Much attention has been given to the control of water levels in the ditch systems within these wet grassland systems. In this paper we report measurements of aeration status and water-table fluctuation made on a peat soil site at Tadham Moor in Somerset, UK, where water management has focused on the maintenance of wet conditions that often result in flooding in winter and wet soil conditions in the spring and summer. Measurement and modelling of the water-table fluctuation indicates the possibility of variability in the aeration of the root environment and anoxic conditions for much of the winter period and for part of the spring and summer. We have used water content and redox potential measurements to characterize the aeration status of the peat soil. We find that air-filled porosity is related to water-table depth in these situations. Redox potentials in the spring were generally found to be low, implying a reducing condition for nitrate and iron. A significant relationship (p < 0.01) between redox potential and water-table depth exists for data measured at 0.1 m depth, but no relationship could be found for data from 0.4 m depth.

  2. Optimum air-demand ratio for maximum aeration efficiency in high-head gated circular conduits.

    PubMed

    Ozkan, Fahri; Tuna, M Cihat; Baylar, Ahmet; Ozturk, Mualla

    2014-01-01

    Oxygen is an important component of water quality and its ability to sustain life. Water aeration is the process of introducing air into a body of water to increase its oxygen saturation. Water aeration can be accomplished in a variety of ways, for instance, closed-conduit aeration. High-speed flow in a closed conduit involves air-water mixture flow. The air flow results from the subatmospheric pressure downstream of the gate. The air entrained by the high-speed flow is supplied by the air vent. The air entrained into the flow in the form of a large number of bubbles accelerates oxygen transfer and hence also increases aeration efficiency. In the present work, the optimum air-demand ratio for maximum aeration efficiency in high-head gated circular conduits was studied experimentally. Results showed that aeration efficiency increased with the air-demand ratio to a certain point and then aeration efficiency did not change with a further increase of the air-demand ratio. Thus, there was an optimum value for the air-demand ratio, depending on the Froude number, which provides maximum aeration efficiency. Furthermore, a design formula for aeration efficiency was presented relating aeration efficiency to the air-demand ratio and Froude number. PMID:25225935

  3. Optimum air-demand ratio for maximum aeration efficiency in high-head gated circular conduits.

    PubMed

    Ozkan, Fahri; Tuna, M Cihat; Baylar, Ahmet; Ozturk, Mualla

    2014-01-01

    Oxygen is an important component of water quality and its ability to sustain life. Water aeration is the process of introducing air into a body of water to increase its oxygen saturation. Water aeration can be accomplished in a variety of ways, for instance, closed-conduit aeration. High-speed flow in a closed conduit involves air-water mixture flow. The air flow results from the subatmospheric pressure downstream of the gate. The air entrained by the high-speed flow is supplied by the air vent. The air entrained into the flow in the form of a large number of bubbles accelerates oxygen transfer and hence also increases aeration efficiency. In the present work, the optimum air-demand ratio for maximum aeration efficiency in high-head gated circular conduits was studied experimentally. Results showed that aeration efficiency increased with the air-demand ratio to a certain point and then aeration efficiency did not change with a further increase of the air-demand ratio. Thus, there was an optimum value for the air-demand ratio, depending on the Froude number, which provides maximum aeration efficiency. Furthermore, a design formula for aeration efficiency was presented relating aeration efficiency to the air-demand ratio and Froude number.

  4. In situ nitrogen removal from leachate by bioreactor landfill with limited aeration

    SciTech Connect

    Shao Liming; He Pinjing Li Guojian

    2008-07-01

    The feasibility of simultaneous nitrification and denitrification in a bioreactor landfill with limited aeration was assessed. Three column reactors, simulating bioreactor landfill operations under anaerobic condition (as reference), intermittent forced aeration and enhanced natural aeration were hence established, where aerated columns passed through two phases, i.e., fresh landfill and well-decomposed landfill. The experimental results show that limited aeration decreased nitrogen loadings of leachate distinctly in the fresh landfill. In the well-decomposed landfill, the NH{sub 4}{sup +}-N of the input leachate could be nitrified completely in the aerated landfill columns. The nitrifying loadings of the column cross section reached 7.9 g N/m{sup 2} d and 16.9 g N/m{sup 2} d in the simulated landfill columns of intermittent forced aeration and enhanced natural aeration, respectively. The denitrification was influenced by oxygen distribution in the landfill column. Intermittent existence of oxygen in the landfill with the intermittent forced aeration was favorable to denitrify the NO{sub 2}{sup -}-N and NO{sub 3}{sup -}-N, indicated by the high denitrification efficiency (>99%) under the condition of BOD{sub 5}/TN of more than 5.4 in leachate; locally persistent existence of oxygen in the landfill with enhanced natural aeration could limit the denitrification, indicated by relatively low denitrification efficiency of about 75% even when the BOD{sub 5}/TN in leachate had an average of 7.1.

  5. The extent of the influence and flux estimation of volatile mercury from the aeration pool in a typical coal-fired power plant equipped with a seawater flue gas desulfurization system.

    PubMed

    Sun, Lumin; Feng, Lifeng; Yuan, Dongxing; Lin, Shanshan; Huang, Shuyuan; Gao, Liangming; Zhu, Yong

    2013-02-01

    Before being discharged, the waste seawater from the flue gas desulfurization system of coal-fired power plants contains a large amount of mercury, and is treated in aeration pools. During this aeration process, part of the mercury enters the atmosphere, but only very limited impact studies concerning this have been carried out. Taking a typical Xiamen power plant as an example, the present study targeted the elemental mercury emitted from the aeration pool. Concentrations of dissolved gaseous mercury as high as 1.14 ± 0.17 ng·L(-1) were observed in the surface waste seawater in the aeration pool, and gaseous elemental mercury (GEM) as high as 10.94 ± 1.89 ng·m(-3) was found in the air above the pool. To investigate the area affected by this GEM through air transfer, the total mercury in the dust and topsoil samples around the aeration pool were analyzed. Much higher values were found compared to those at a reference site. Environmental factors other than solar radiation had limited influence on the concentrations of the mercury species in the pool. A simulation device was built in our laboratory to study the flux of mercury from the aeration pool into the air. The results showed that more than 0.59 kg of mercury was released from the aeration pool every year, occupying 0.3% of the total mercury in the waste seawater. The transfer of mercury from water to air during the aeration pool and its environmental influence should not be ignored.

  6. The extent of the influence and flux estimation of volatile mercury from the aeration pool in a typical coal-fired power plant equipped with a seawater flue gas desulfurization system.

    PubMed

    Sun, Lumin; Feng, Lifeng; Yuan, Dongxing; Lin, Shanshan; Huang, Shuyuan; Gao, Liangming; Zhu, Yong

    2013-02-01

    Before being discharged, the waste seawater from the flue gas desulfurization system of coal-fired power plants contains a large amount of mercury, and is treated in aeration pools. During this aeration process, part of the mercury enters the atmosphere, but only very limited impact studies concerning this have been carried out. Taking a typical Xiamen power plant as an example, the present study targeted the elemental mercury emitted from the aeration pool. Concentrations of dissolved gaseous mercury as high as 1.14 ± 0.17 ng·L(-1) were observed in the surface waste seawater in the aeration pool, and gaseous elemental mercury (GEM) as high as 10.94 ± 1.89 ng·m(-3) was found in the air above the pool. To investigate the area affected by this GEM through air transfer, the total mercury in the dust and topsoil samples around the aeration pool were analyzed. Much higher values were found compared to those at a reference site. Environmental factors other than solar radiation had limited influence on the concentrations of the mercury species in the pool. A simulation device was built in our laboratory to study the flux of mercury from the aeration pool into the air. The results showed that more than 0.59 kg of mercury was released from the aeration pool every year, occupying 0.3% of the total mercury in the waste seawater. The transfer of mercury from water to air during the aeration pool and its environmental influence should not be ignored. PMID:23305917

  7. The effects of agitation and aeration on the production of gluconic acid by Aspergillus niger

    SciTech Connect

    Dronawat, S.N.; Svihla, C.K.; Hanley, T.R.

    1995-12-31

    The effects of agitation and aeration in the production of gluconic acid by Aspergillus niger from a glucose medium were investigated. Experiments were conducted at aeration rates of 5.0 and 10.0 L/min. Four different agitation speeds were investigated for each aeration rate. Gluconic acid concentration and biomass concentration were analyzed, and the rate of consumption of substrate by A. niger was noted. The main purpose of this work was to find the optimal conditions of agitation and aeration for the growth of A. niger and production of gluconic acid in submerged culture in a batch fermentor at a bench-top scale. The oxygen-transfer rates at different agitation and aeration rates were calculated. The gluconic acid concentration and rate of growth of A. niger increased with increase in the agitation and aeration rates.

  8. Stratification structure of polysaccharides and proteins in activated sludge with different aeration in membrane bioreactor.

    PubMed

    Zhang, Haifeng; Yu, Haihuan; Zhang, Lanhe; Song, Lianfa

    2015-09-01

    The effect of distribution pattern of polysaccharides (PS) and proteins (PN) in activated sludge (AS) stratification with different aeration rates on membrane fouling and rejection efficiency were investigated. During high aeration, PN and PS concentrations increased in supernatant, the dominant fraction (84% of PN and 73% of PS) was small molecules (<1 kDa). Less slime and loose bound extracellular polymeric substances (LB-EPS), more tight bound EPS (TB-EPS) were observed compared with low aeration. The decrease in PN/PS ratio and Ca(2+) concentration within EPS deteriorated AS flocculation ability. At slow trans-membrane pressure (TMP) rise stage, fouling rate under high aeration was 41% lower than low aeration due to lower PN within EPS outer. Low PS rejection rate (about 23%) leaded to higher PS in effluent at this stage. High PS rejection rate (about 94%) at rapid TMP rise stage resulted in about 2.2-time higher fouling rate than that low aeration.

  9. Effect of Aeration and Circulation Treatment of Effluent on Wastewater Purification Functions of a Planted Canal

    NASA Astrophysics Data System (ADS)

    Tsuji, Morio; Yamada, Kazuhiro; Hiratsuka, Akira

    Water purification characteristic evaluation was done for adding aeration and circulation to a canal planted with Carex dispalata, which is a Japanese native species whose height does not obstruct the view. Circulation improved the BOD removal efficiency, irrespective of the use of aeration. Aeration improved the BOD removal efficiency in the condition of circulation ON. The BOD removal rate without any circulation was 15g·m-2·d-1, which was the maximum, suggesting that it can be raised higher than 20g·m-2·d-1 through the use of aeration and circulation. The D-BOD removal effect is high. Therefore, removal of the organic pollution load by bacteria increased. The nitrogen removal efficiency did not increase because nitrification by aeration did not advance. Instead of energy-intensive aeration, it is necessary to consider the oxidative capacity of nitrification.

  10. Effects of aeration position on organics, nitrogen and phosphorus removal in combined oxidation pond-constructed wetland systems.

    PubMed

    Wang, Xiaoou; Tian, Yimei; Zhao, Xinhua; Peng, Sen; Wu, Qing; Yan, Lijian

    2015-12-01

    Given that few studies investigated the effects of aeration position (AP) on the performance of aerated constructed wetlands, the aim of this study was to evaluate the effects of AP on organics, nitrogen and phosphorus removal in lab-scale combined oxidation pond-constructed wetland (OP-CW) systems. Results showed that middle aeration allowed the CW to possess more uniform oxygen distribution and to achieve greater removals of COD and NH3-N, while the CW under bottom aeration and surface aeration demonstrated more distinct stratification of oxygen distribution and surface aeration brought about better TN removal capacity for the OP-CW system. However, no significant influence of artificial aeration or AP on TP removal was observed. Overall, AP could significantly affect the spatial distribution of dissolved oxygen by influencing the oxygen diffusion paths in aerated CWs, thereby influencing the removal of pollutants, especially organics and nitrogen, which offers a reference for the design of aerated CWs.

  11. CFD study to determine the optimal configuration of aerators in a full-scale waste stabilization pond.

    PubMed

    Alvarado, Andres; Vesvikar, Mehul; Cisneros, Juan F; Maere, Thomas; Goethals, Peter; Nopens, Ingmar

    2013-09-01

    Aerated lagoons (ALs) are important variants of the pond wastewater treatment technology that have not received much attention in the literature. The hydraulic behaviour of ALs and especially the Facultative aerated lagoons (FALs) is very complex since the aeration in these systems is designed for oxygen transfer but not necessarily to create complete mixing. In this work, the energy expenditure of the aerators was studied by means of a scenario analysis. 3D CFD models (one phase and multiphase) of a 3 ha FAL in a waste stabilization pond system in Cuenca (Ecuador) were built for different configurations of aerators. The thrust produced by the aerators was modelled by an external momentum source applied as velocity vectors into the pond fluid. The predictions of a single phase model were in satisfactory agreement with experimental results. Subsequently, a scenario analysis assessing several aeration schemes with different numbers of aerators in operation were tested with respect to velocity profiles and residence time distribution (RTD) curves. This analysis showed that the aeration scheme with all 10 aerators switched on produces a similar hydraulic behaviour compared to using only 6 or 8 aerators. The current operational schemes comprise of switching off some aerators during the peak hours of the day and operating all 10 aerators during night. This current practice could be economically replaced by continuously operating 4 or 6 aerators without significantly affecting the overall mixing. Furthermore, a continuous mixing regime minimises the sediment oxygen demand enhancing the oxygen levels in the pond. PMID:23764602

  12. Lung mass, right upper lung - chest x-ray (image)

    MedlinePlus

    This picture is a chest x-ray of a person with a lung mass. This is a front view, where the lungs are the two dark areas and ... visible in the middle of the chest. The x-ray shows a mass in the right upper lung, ...

  13. Bioreactor tests preliminary to landfill in situ aeration: A case study

    SciTech Connect

    Raga, Roberto; Cossu, Raffaello

    2013-04-15

    Highlights: ► Carbon and nitrogen mass balances in aerated landfill simulation reactors. ► Waste stabilization in aerated landfill simulation reactors. ► Effect of temperature on biodegradation processes in aerated landfills. - Abstract: Lab scale tests in bioreactor were carried out in the framework of the characterization studies of a landfill where in situ aeration (possibly followed by landfill mining) had been proposed as part of the novel waste management strategy in a region in northern Italy. The tests were run to monitor the effects produced by aerobic conditions at different temperatures on waste sampled at different depths in the landfill, with focus on the carbon and nitrogen conversion during aeration. Temperatures ranging from 35 to 45 °C were chosen, in order to evaluate possible inhibition of biodegradation processes (namely nitrification) at 45 °C in the landfill. The results obtained showed positive effects of the aeration on leachate quality and a significant reduction of waste biodegradability. Although a delay of biodegradation processes was observed in the reactor run at 45 °C, biodegradation rates increased after 2 months of aeration, providing very low values of the relevant parameters (as in the other aerated reactors) by the end of the study. Mass balances were carried out for TOC and N-NH{sub 4}{sup +}; the findings obtained were encouraging and provided evidence of the effectiveness of carbon and nitrogen conversion processes in the aerated landfill simulation reactors.

  14. Water quality and bacteriology in an aquaculture facility equipped with a new aeration system.

    PubMed

    Fernandes, Sheryl O; Kulkarni, Shantanu S; Shirodkar, Resha R; Karekar, Sheetal V; Kumar, R Praveen; Sreepada, R A; Vogelsang, Christian; Loka Bharathi, P A

    2010-05-01

    The HOBAS aeration system was tested to compare changes in environmental and bacteriological parameters in ponds growing Penaeus monodon during a single production cycle. The stocking density in the aerated pond was doubled to 12 post-larvae (PL) m(-2) in contrast to the non-aerated pond with 6 (PL) m(-2). Microbial abundance in the ponds ranged between 10(5-6) cells ml(-1). Among the physiological groups of bacteria enumerated, the heterotrophs dominated with an abundance of 10(4) CFU ml(-1). Of the nitrogen and sulfur cycle bacteria, the nitrifiers flourished in the aerated pond and could maintain ammonia-N concentration within permissible levels. Bacterial activity also maintained sulfide concentrations at < 0.03 mg l(-1). Non-aerated conditions promoted denitrification maintaining nitrate concentration between 0.32 and 0.98 microM NO(3)(-)-N l(-1). However, a marked increase in ammonium content was observed in the non-aerated pond at the end of the culture period. Thus in high-density ponds, the aerators served to stimulate bacterial growth and activity which consequently maintained the quality of the water to match that of low-density ponds. Accordingly, these aerators could be effectively used to sustain higher yields. The effluent from the aerated pond is less likely to alter the redox balance of the receiving waters.

  15. Landfill aeration in the framework of a reclamation project in Northern Italy.

    PubMed

    Raga, Roberto; Cossu, Raffaello

    2014-03-01

    In situ aeration by means of the Airflow technology was proposed for landfill conditioning before landfill mining in the framework of a reclamation project in Northern Italy. A 1-year aeration project was carried out on part of the landfill with the objective of evaluating the effectiveness of the Airflow technology for landfill aerobization, the evolution of waste biological stability during aeration and the effects on leachate and biogas quality and emissions. The main outcomes of the 1-year aeration project are presented in the paper. The beneficial effect of the aeration on waste biological stability was clear (63% reduction of the respiration index); however, the effectiveness of aeration on the lower part of the landfill is questionable, due to the limited potential for air migration into the leachate saturated layers. During the 1-year in situ aeration project approx. 275 MgC were discharged from the landfill body with the extracted gas, corresponding to 4.6 gC/kgDM. However, due to the presence of anaerobic niches in the aerated landfill, approx. 46% of this amount was extracted as CH4, which is higher than reported in other aeration projects. The O2 conversion quota was lower than reported in other similar projects, mainly due to the higher air flow rates applied. The results obtained enabled valuable recommendations to be made for the subsequent application of the Airflow technology to the whole landfill.

  16. [Effect of aeration intensity on the nitrogen and phosphorus removal performance of AOA membrane bioreactors].

    PubMed

    Chen, Xiao-Yang; Xue, Zhi-Yong; Xiao, Jing-Ni; Zhang, Han-Min; Yang, Feng-Lin; Wang, Wei-Ping; Hong, Chun-Lai; Zhu, Feng-Xiang

    2011-10-01

    The ability of simultaneous phosphorus and nitrogen removal of sequencing batch membrane bioreactor run in anaerobic/oxic/ anoxic mode (AOA MBR) was examined under three aeration intensities [2.5, 3.75 and 5.0 m3 x (m2 x h)(-10]. The results showed that the averaged removals of COD were over 90% at different aeration intensities. And the higher aeration intensity was, the more ammonia nitrogen removal rate achieved. The removal rates of NH4(+) under the three aeration intensities were 84.7%, 90.6% and 93.8%, respectively. Total nitrogen removal rate increased with the increasing aeration intensity. But excessive aeration intensity reduced TN removal. The removal rates of TN under the three aeration intensities were 83.4%, 87.4% and 80.6%, respectively. Aeration intensity affected the denitrifying phosphorus ability of the AOA MBR. The ratio of denitrification phosphorus removal under the three aeration intensities were 20%, 30.2% and 26.7%, respectively.

  17. Effect of influent aeration on removal of organic matter from coffee processing wastewater in constructed wetlands.

    PubMed

    Rossmann, Maike; Matos, Antonio Teixeira; Abreu, Edgar Carneiro; Silva, Fabyano Fonseca; Borges, Alisson Carraro

    2013-10-15

    The aim of the present study was to evaluate the influence of aeration and vegetation on the removal of organic matter in coffee processing wastewater (CPW) treated in 4 constructed wetlands (CWs), characterized as follows: (i) ryegrass (Lolium multiflorum) cultivated system operating with an aerated influent; (ii) non-cultivated system operating with an aerated influent, (iii) ryegrass cultivated system operating with a non-aerated influent; and (iv) non-cultivated system operating with a non-aerated influent. The lowest average chemical oxygen demand (COD), biochemical oxygen demand (BOD) and total suspended solids (TSS) removal efficiencies of 87, 84 and 73%, respectively, were obtained in the ryegrass cultivated system operating with a non-aerated influent. However, ryegrass cultivation did not influence the removal efficiency of organic matter. Artificial aeration of the CPW, prior to its injection in the CW, did not improve the removal efficiencies of organic matter. On other hand it did contribute to increase the instantaneous rate at which the maximum COD removal efficiency was reached. Although aeration did not result in greater organic matter removal efficiencies, it is important to consider the benefits of aeration on the removal of the other compounds.

  18. Partial nitritation ANAMMOX in submerged attached growth bioreactors with smart aeration at 20 °C.

    PubMed

    Shannon, James M; Hauser, Lee W; Liu, Xikun; Parkin, Gene F; Mattes, Timothy E; Just, Craig L

    2015-01-01

    Submerged attached growth bioreactors (SAGBs) were operated at 20 °C for 30 weeks in smart-aerated, partial nitritation ANAMMOX mode and in a timer-controlled, cyclic aeration mode. The smart-aerated SAGBs removed 48-53% of total nitrogen (TN) compared to 45% for SAGBs with timed aeration. Low dissolved oxygen concentrations and cyclic pH patterns in the smart-aerated SAGBs suggested conditions favorable to partial nitritation ANAMMOX and stoichiometrically-derived and numerically modeled estimations attributed 63-68% and 14-44% of TN removal to partial nitritation ANAMMOX in these bioreactors, respectively. Ammonia removals of 36-67% in the smart-aerated SAGBs, with measured oxygen and organic carbon limitations, further suggest partial nitritation ANAMMOX. The smart-aerated SAGBs required substantially less aeration to achieve TN removals similar to SAGBs with timer-controlled aeration. Genomic DNA testing confirmed that the dominant ANAMMOX seed bacteria, received from a treatment plant utilizing the DEMON® sidestream deammonification process, was a Candidatus Brocadia sp. (of the Planctomycetales order). The DNA from these bacteria was also present in the SAGBs at the conclusion of the study providing evidence for attached growth and limited biomass washout.

  19. Method and apparatus for energy efficient self-aeration in chemical, biochemical, and wastewater treatment processes

    DOEpatents

    Gao, Johnway [Richland, WA; Skeen, Rodney S [Pendleton, OR

    2002-05-28

    The present invention is a pulse spilling self-aerator (PSSA) that has the potential to greatly lower the installation, operation, and maintenance cost associated with aerating and mixing aqueous solutions. Currently, large quantities of low-pressure air are required in aeration systems to support many biochemical production processes and wastewater treatment plants. Oxygen is traditionally supplied and mixed by a compressor or blower and a mechanical agitator. These systems have high-energy requirements and high installation and maintenance costs. The PSSA provides a mixing and aeration capability that can increase operational efficiency and reduce overall cost.

  20. Lung disease

    MedlinePlus

    ... the lungs to take in oxygen and release carbon dioxide. People with this type of lung disorder often ... the lungs to take up oxygen and release carbon dioxide. These diseases may also affect heart function. An ...

  1. Nitrogen-removal performance and community structure of nitrifying bacteria under different aeration modes in an oxidation ditch.

    PubMed

    Guo, Chang-Zi; Fu, Wei; Chen, Xue-Mei; Peng, Dang-Cong; Jin, Peng-Kang

    2013-07-01

    Oxidation-ditch operation modes were simulated using sequencing batch reactors (SBRs) with alternate stirring and aerating. The nitrogen-removal efficiencies and nitrifying characteristics of two aeration modes, point aeration and step aeration, were investigated. Under the same air-supply capacity, oxygen dissolved more efficiently in the system with point aeration, forming a larger aerobic zone. The nitrifying effects were similar in point aeration and step aeration, where the average removal efficiencies of NH4(+) N were 98% and 96%, respectively. When the proportion of anoxic and oxic zones was 1, the average removal efficiencies of total nitrogen (TN) were 45% and 66% under point aeration and step aeration, respectively. Step aeration was more beneficial to both anoxic denitrification and simultaneous nitrification and denitrification (SND). The maximum specific ammonia-uptake rates (AUR) of point aeration and step aeration were 4.7 and 4.9 mg NH4(+)/(gMLVSS h), respectively, while the maximum specific nitrite-uptake rates (NUR) of the two systems were 7.4 and 5.3 mg NO2(-)-N/(gMLVSS h), respectively. The proportions of ammonia-oxidizing bacteria (AOB) to all bacteria were 5.1% under point aeration and 7.0% under step aeration, and the proportions of nitrite-oxidizing bacteria (NOB) reached 6.5% and 9.0% under point and step aeration, respectively. The dominant genera of AOB and NOB were Nitrosococcus and Nitrospira, which accounted for 90% and 91%, respectively, under point aeration, and the diversity of nitrifying bacteria was lower than under step aeration. Point aeration was selective of nitrifying bacteria. The abundance of NOB was greater than that of AOB in both of the operation modes, and complete transformation of NH4(+) N to NO3(-)-N was observed without NO2(-)-N accumulation.

  2. Mineralogical and compositional characteristics of Late Permian coals from an area of high lung cancer rate in Xuan Wei, Yunnan, China: Occurrence and origin of quartz and chamosite

    USGS Publications Warehouse

    Dai, S.; Tian, L.; Chou, C.-L.; Zhou, Y.; Zhang, M.; Zhao, L.; Wang, Jingyuan; Yang, Z.; Cao, H.; Ren, D.

    2008-01-01

    Some townships in Xuan Wei County, Yunnan Province, have one of the highest lung cancer mortality rates in China and the epidemic disease in the area has generally been attributed to the polycyclic aromatic hydrocarbons (PAHs) released from domestic coal burning. However, the cancer-causing culprit is not settled as Tian [Tian, L., 2005. Coal Combustion Emissions and Lung Cancer in Xuan Wei, China. Ph.D. thesis, University of California, Berkeley.] found nanometer quartz in these coals, soot emissions, and lung cancer tissues. We have conducted mineralogical and geochemical studies of the coals from Xuan Wei for the purpose of shedding light on the minerals which may be related to the epidemic lung cancer. In this paper, abundances, modes of occurrence, and origins of minerals and elements in the coals from two mines in Xuan Wei have been studied using optical microscope, low-temperature ashing, X-ray diffraction analysis, scanning electron microscope equipped with energy-dispersive X-ray spectrometer, and inductively-coupled plasma mass spectrometry. The minerals in the coals are mainly composed of quartz, chamosite, kaolinite, and calcite. The particle size of quartz is rather small, mostly less than 20????m and it is of authigenic origin. Chamosite occurs mainly as cell-fillings. The occurrence of quartz and chamosite indicates that they were derived from the hydrothermal fluids. Epigenetic calcite is derived from calcic fluids. Kaolinite is derived mainly from sediment source region of Kangdian Oldland to the west of coal basin. The composition of Xuan Wei coal is high in SiO2, Fe2O3, TiO2, CaO, MnO, V, Co, Ni, Cu, and Zn. The high SiO2 content is attributed to quartz, and the Fe2O3 content to chamosite. The high Mn and low Mg contents in the coal indicate the inputs of hydrothermal fluids. CaO occurs mainly in epigenetic calcite. Elements Ti, Co, Ni, Cu, Zn, and rare earth elements were derived from the basaltic rocks at sediment source region. ?? 2008

  3. Pseudomonads Rule Degradation of Polyaromatic Hydrocarbons in Aerated Sediment

    PubMed Central

    Wald, Jiri; Hroudova, Miluse; Jansa, Jan; Vrchotova, Blanka; Macek, Tomas; Uhlik, Ondrej

    2015-01-01

    Given that the degradation of aromatic pollutants in anaerobic environments such as sediment is generally very slow, aeration could be an efficient bioremediation option. Using stable isotope probing (SIP) coupled with pyrosequencing analysis of 16S rRNA genes, we identified naphthalene-utilizing populations in aerated polyaromatic hydrocarbon (PAH)-polluted sediment. The results showed that naphthalene was metabolized at both 10 and 20°C following oxygen delivery, with increased degradation at 20°C as compared to 10°C—a temperature more similar to that found in situ. Naphthalene-derived 13C was primarily assimilated by pseudomonads. Additionally, Stenotrophomonas, Acidovorax, Comamonas, and other minor taxa were determined to incorporate 13C throughout the measured time course. The majority of SIP-detected bacteria were also isolated in pure cultures, which facilitated more reliable identification of naphthalene-utilizing populations as well as proper differentiation between primary consumers and cross-feeders. The pseudomonads acquiring the majority of carbon were identified as Pseudomonas veronii and Pseudomonas gessardii. Stenotrophomonads and Acidovorax defluvii, however, were identified as cross-feeders unable to directly utilize naphthalene as a growth substrate. PAH degradation assays with the isolated bacteria revealed that all pseudomonads as well as Comamonas testosteroni degraded acenaphthene, fluorene, and phenanthrene in addition to naphthalene. Furthermore, P. veronii and C. testosteroni were capable of transforming anthracene, fluoranthene, and pyrene. Screening of isolates for naphthalene dioxygenase genes using a set of in-house designed primers for Gram-negative bacteria revealed the presence of such genes in pseudomonads and C. testosteroni. Overall, our results indicated an apparent dominance of pseudomonads in the sequestration of carbon from naphthalene and potential degradation of other PAHs upon aeration of the sediment at both 20 and

  4. [Biological phosphorus removal in intermittent aerated biological filter].

    PubMed

    Zeng, Long-Yun; Yang, Chun-Ping; Guo, Jun-Yuan; Luo, Sheng-Lian

    2012-01-01

    Under intermittent aerated and continuous fed operation where the biofilm system was subjected to alternated anaerobic/aerobic condition, the effect of influent volatile fatty acids (VFAs) concentrations, operation cycle and backwash on the biological phosphorus removal performance of the biofilter was studied. In the experiment, synthetic domestic wastewater was used, and the influent velocity was 5 L x h(-1) with gas versus liquid ratio of 8:1 and hydraulic retention time (HRT) of 1.3 h, resulting in average COD, ammonium and phosphorus load of 4.7, 0.41 and 0.095 g x (L x d) (-1) respectively. Results show that, (1) effective release and uptake of phosphorus was achieved in a operation cycle; (2) when influent VFAs was 100 mg x L(-1) (calculated by COD value) and operation cycle was 6 h the filter performed best in phosphorus removal, the phosphorus loading removal rate can be as much as 0.059 g x (L x d)(-1) at the aerated phase with those of COD and ammonium being 3.8 g x (L x d)(-1) and 0.28 g x (L x d)(-1) respectively, and with average effluent phosphorus, COD and ammonium concentrations being 1.8, 43.6 and 8.7 mg x L(-1), which shows nitrogen loss also happened; (3) the pause of backwash decreased the phosphorus removal performance rapidly with the removal efficiency lower than 40% in two days, but the consequent daily backwash operation gave a short improvement on the phosphorus removal, which disappeared in another two days. Thus, it is shown that biological phosphorus removal achieved with better phosphorus loading removal performance in the biofilter under intermittent aerated and continuous fed operation, and that sufficient and stable influent VFAs concentration, proper operation cycle, and more frequent backwash favored the performance.

  5. Pulverizing aeration as a method of lakes restoration

    NASA Astrophysics Data System (ADS)

    Kaczorowska, E.; Podsiadłowski, S.

    2012-04-01

    The principal threat to lakes of the temperate zone is posed by factors accelerating their eutrophication and causing marked deoxygenation of the deeper layers of water, mainly the hypo- and metalimnion. Among their effects are frequent phytoplankton blooms, including those of blue-green algae, and general deterioration of water quality also affecting the abundance and health status of fish. The chief concern is a disturbed proportion between the amount of complex chemical compounds, especially organic, and the oxygen content of lake waters. Natural processes of water oxygenation are not too intensive, because they are practically limited to the epilimnion layer, connected as they are with the activity of aquatic plants of the littoral and sublittoral zone (which tends to disappear in contaminated lakes) and wind energy (the effect of waving). In summer conditions, with a relatively great chemical activity of bottom deposits, the intensity of those processes is usually inadequate. Hence, in 1995 a research was launched in the Institute of Agricultural Engineering of the Agricultural University in Poznań on an integrated lake restoration technology whose core was a self-powered aerator capable of oxygenating also the bottom layers of water (the hypolimnion) of deep lakes. The aerator uses energy obtained from a Savonius rotor mainly to diffuse gases: to release hydrogen sulphide, which usually saturates the hypolimnion water completely, and then to saturate this water with oxygen. Even early studies showed the constructed device to be highly efficient in improving oxygen conditions in the bottom zone. They also made it clear that it should be equipped with an autonomous system designed to inactivate phosphorus, one of the principal factors determining the rate of lake degradation. In 2003 the first wind-driven pulverising aerator equipped with such a system was installed in Town Lake in Chodzież. The aim of this work is to present the principles of operation of a

  6. Particles induce apical plasma membrane enlargement in epithelial lung cell line depending on particle surface area dose

    PubMed Central

    Brandenberger, Christina; Rothen-Rutishauser, Barbara; Blank, Fabian; Gehr, Peter; Mühlfeld, Christian

    2009-01-01

    Background Airborne particles entering the respiratory tract may interact with the apical plasma membrane (APM) of epithelial cells and enter them. Differences in the entering mechanisms of fine (between 0.1 μm and 2.5 μm) and ultrafine ( ≤ 0.1 μm) particles may be associated with different effects on the APM. Therefore, we studied particle-induced changes in APM surface area in relation to applied and intracellular particle size, surface and number. Methods Human pulmonary epithelial cells (A549 cell line) were incubated with various concentrations of different sized fluorescent polystyrene spheres without surface charge (∅ fine – 1.062 μm, ultrafine – 0.041 μm) by submersed exposure for 24 h. APM surface area of A549 cells was estimated by design-based stereology and transmission electron microscopy. Intracellular particles were visualized and quantified by confocal laser scanning microscopy. Results Particle exposure induced an increase in APM surface area compared to negative control (p < 0.01) at the same surface area concentration of fine and ultrafine particles a finding not observed at low particle concentrations. Ultrafine particle entering was less pronounced than fine particle entering into epithelial cells, however, at the same particle surface area dose, the number of intracellular ultrafine particles was higher than that of fine particles. The number of intracellular particles showed a stronger increase for fine than for ultrafine particles at rising particle concentrations. Conclusion This study demonstrates a particle-induced enlargement of the APM surface area of a pulmonary epithelial cell line, depending on particle surface area dose. Particle uptake by epithelial cells does not seem to be responsible for this effect. We propose that direct interactions between particle surface area and cell membrane cause the enlargement of the APM. PMID:19284624

  7. Sidestream Elevated Pool Aeration, a Technology for Improving Water Quality in Urban Rivers

    NASA Astrophysics Data System (ADS)

    Motta, D.; Garcia, T.; Abad, J. D.; Bombardelli, F. A.; Waratuke, A.; Garcia, M. H.

    2010-12-01

    Dissolved Oxygen (DO) levels are frequently depleted in rivers located in urban areas, as in the case of the Matanza-Riachuelo River in Buenos Aires, Argentina. This stream receives both domestic and industrial loads which have received minor or no treatment before being discharged into the water body. Major sources of pollution include, but are not limited, to leather and meat packing industries. Additionally, deep slow moving water in the river is associated with limited reaeration and facilitates deposition of organic-rich sediment, therefore exacerbating the DO consumption through sediment oxygen demand. In this study we assessed the efficiency of Sidestream Elevated Pool Aeration (SEPA) stations as a technology for alleviating conditions characterized by severely low DO levels. A SEPA station takes water from the stream at low DO concentrations, through a screw pump; then, water is transported to an elevated pool from where it flows over a series of weirs for water reaeration; finally, the aerated water is discharged back into the river sufficiently downstream from the intake point. This system mimics a phenomenon that occurs in mountain streams, where water is purified by bubbling over rocks. The impact of the use of SEPA stations on the DO concentrations in the Matanza-Riachuelo River was evaluated at both local and reach scales: this was done by deploying and monitoring an in situ pilot SEPA station, and by performing numerical modeling for the evaluation of the hydrodynamics in the SEPA station and the water quality in the reach where SEPA stations are planned to be implemented. An efficiency of aeration of 99% was estimated from DO measurements in the pilot SEPA, showing the potential of this technology for DO recovery in urban streams. Three-dimensional hydrodynamic modeling, besides assisting in the design of the pilot SEPA, has allowed for designing a prototype SEPA to be built soon. Finally, one-dimensional water quality modeling has provided the

  8. Final Report: Retrofit Aeration System (RAS) for Francis Turbine

    SciTech Connect

    Alan Sullivan; DOE Project Officer Keith Bennett

    2006-08-01

    Osage Plant and Bagnell Dam impounds the Osage River forming the Lake of the Ozarks in Missouri. Since it is nearly 100 feet deep, the lake stratifies during the summer months causing low DO water to be discharged into the Osage river below the dam. To supplement DO, the turbines are vented during the low DO season. AmerenUE is continually researching new methods of DO enhancement. New turbines, manufactured by American Hydro Corporation, were installed in Units 3 & 5 during the spring of 2002. Additional vent capacity and new nosecones were included in the new turbine design. The retrofit aeration system is an attempt to further enhance the DO in the tailrace by installation of additional venting capability on Unit 6 (not upgraded with new turbine) and refining design on special nosecones which will be mounted on both Unit 3 (upgraded turbine) and Unit 6. Baseline DO testing for Units 3 & 6 was conducted mid August, 2002. This data wascompared to further tests planned for the summer of 2003 and 2004 after installation of the retrofit aeration system.

  9. Feasibility of biological aerated filters (BAFs) for treating landfill leachate.

    PubMed

    Stephenson, T; Pollard, S J T; Cartmell, E

    2004-03-01

    Ammonia can be removed from landfill leachate using aerobic biological treatment processes. The biological aerated filter (BAF) combines biological treatment and subsequent biomass separation in one reactor providing a small footprint alternative to conventional systems. Leachate from an operational landfill was found to be aerobically treatable using the OECD recommended Modified Zahn-Wellens test. This leachate was used as feed to a pilot-scale BAF at influent chemical oxygen demand (COD) and ammoniacal-nitrogen concentrations of 765 mg l(-1) and 568 mg l(-1) respectively. During an initial period of stable operation without pH control, 33 %w/w of influent ammonia was removed. The reactor pH was 9.2 with little conversion to total oxidized nitrogen (< 45 mg l(-1)), this removal was accounted for primarily by air stripping. In a second period of stable operation, the reactor pH was reduced to pH 7.2 and ammonia removal increased to 97 %w/w with a concomitant increase in effluent nitrite concentration to an average of 524 mg l(-1). Biological aerated filters (BAFs) can be used to nitrify landfill leachates though onward denitrification of nitrite-nitrogen and COD polishing is required to reach typical discharge consent standards.

  10. Galvanic corrosion of nitinol under deaerated and aerated conditions.

    PubMed

    Pound, Bruce G

    2016-10-01

    Various studies have examined the corrosion rate of nitinol generally under deaerated conditions. Likewise, galvanic corrosion studies have typically involved deaerated solutions. This work addressed the effect of galvanic coupling on the corrosion current of electropolished nitinol in phosphate buffered saline and 0.9% sodium chloride under dearated and aerated conditions for times up to 24 h. Tests were performed on nitinol alone and coupled with MP35N in both the mechanically polished and passivated conditions. Aeration and galvanic coupling were found to have relatively little effect, indicating that the corrosion current is controlled by the anodic reaction. The current can be attributed entirely to Ni(2+) dissolution, which appears to be governed by solid-state mass transport of Ni(2+) through the passive oxide film. Because corrosion of EP nitinol is controlled by the anodic reaction, contact between EP nitinol and MP35N or other biomedical Co-Cr alloys is unlikely to result in significant galvanic effects in vivo. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1322-1327, 2016.

  11. The use of bottle caps as submerged aerated filter medium.

    PubMed

    Damasceno de Oliveira, Laurence; Motlagh, Amir Mohaghegh; Goel, Ramesh; de Souza Missagia, Beatriz; Alves de Abreu Filho, Benício; Lautenschlager, Sandro Rogério

    2014-01-01

    In this study, a submerged aerated filter (SAF) using bottle caps as a support medium was evaluated. The system was fed with effluent from an upflow anaerobic sludge blanket system at ETE 2-South wastewater treatment plant, under different volumetric organic load rates (VOLRs). The population of a particular nitrifying microbial community was assessed by fluorescent in situ hybridization with specific oligonucleotide probes. The system showed an average removal of chemical oxygen demand (COD) equal to 76% for VOLRs between 2.6 and 13.6 kg COD m(-3)_media.day(-1). The process of nitrification in conjunction with the removal of organic matter was observed from applying VOLRs lower than 5.5 kg COD m(-3)_media.day(-1) resulting in 78% conversion of NH4(+)-N. As the applied organic load was reduced, an increase in the nitrifying bacteria population was observed compared with total 4'-6-diamidino-2-phenylindole (DAPI) stained cells. Generally, SAF using bottle caps as a biological aerated filter medium treating wastewater from an anaerobic system showed promising removal of chemical oxygen demand (COD) and conversion of NH4(+)-N. PMID:24718345

  12. Aerated Shewanella oneidensis in Continuously-fed Bioelectrochemical Systems for Power and Hydrogen Production

    Technology Transfer Automated Retrieval System (TEKTRAN)

    We studied the effects of aeration of Shewanella oneidensis on potentiostatic current production, iron(III) reduction, hydrogen production in a microbial electrolysis cell, and electric power generation in a microbial fuel cell. The potentiostatic performance of aerated S. oneidensis was considerab...

  13. Bench scale studies of the soil aeration process for bioremediation of petroleum hydrocarbons

    SciTech Connect

    Hinchee, R.E.; Arthur, M.

    1991-12-31

    An alternative to traditional hydrocarbon bioremediation is to pump air through unsaturated soils to create aerobic conditions and induce biodegradation. This study examines the effects of moisture and nutrient augmentation on biodegradation of petroleum hydrocarbons in aerated soils. Findings indicate that forced aeration, coupled with additions of nutrients and moisture, stimulate hydrocarbon-degrading microorganisms and present a feasible approach to bioremediation management.

  14. Surfactant effects on alpha factors in full-scale wastewater aeration systems.

    PubMed

    Rosso, D; Larson, L E; Stenstrom, M K

    2006-01-01

    Aeration is an essential process in the majority of wastewater treatment processes, and accounts for the largest fraction of plant energy costs. Aeration systems can achieve wastewater oxygenation by shearing the surface (surface aerators) or releasing bubbles at the bottom of the tank (coarse- or fine-bubble aerators). Surfactants accumulate on gas-liquid interfaces and reduce mass transfer rates. This reduction in general is larger for fine-bubble aerators. This study was conducted to evaluate mass transfer effects on the characterization and specification of aeration systems in clean and process water conditions. Tests at different interfacial turbulence regimes were analysed, showing higher gas transfer depression for lower turbulence regimes. Higher turbulence regimes can offset contamination effects, at the expense of operating efficiency. This phenomenon is characteristic of surface aerators and coarse bubble diffusers and is here discussed. The results explain the variability of alpha factors measured at small scale, due to uncontrolled energy density. Results are also reported in dimensionless empirical correlations that describe mass transfer as a function of physiochemical and geometrical characteristics of the aeration process. PMID:17165457

  15. Hydraulic characterization and optimization of total nitrogen removal in an aerated vertical subsurface flow treatment wetland.

    PubMed

    Boog, Johannes; Nivala, Jaime; Aubron, Thomas; Wallace, Scott; van Afferden, Manfred; Müller, Roland Arno

    2014-06-01

    In this study, a side-by-side comparison of two pilot-scale vertical subsurface flow constructed wetlands (6.2 m(2)×0.85 m, q(i)=95 L/m(2) d, τ(n)=3.5 d) handling primary treated domestic sewage was conducted. One system (VA-i) was set to intermittent aeration while the other was aerated continuously (VAp-c). Intermittent aeration was provided to VA-i in an 8 h on/4 h off pattern. The intermittently aerated wetland, VA-i, was observed to have 70% less nitrate nitrogen mass outflow than the continuously aerated wetland, VAp-c. Intermittent aeration was shown to increase treatment performance for TN while saving 33% of running energy cost for aeration. Parallel tracer experiments in the two wetlands showed hydraulic characteristics similar to one Continuously Stirred Tank Reactor (CSTR). Intermittent aeration did not significantly affect the hydraulic functioning of the system. Hydraulic efficiencies were 78% for VAp-c and 76% for VA-i.

  16. [Impacts of different aeration modes on nutrients conservation during swine manure composting with magnesium salt addition].

    PubMed

    Yang, Yu; Wei, Yuan-Song; Liu, Jun-Xin

    2009-04-15

    Experiments were carried out to investigate the effect of two aeration modes on nutrients conservation in the thermophilic stage of swine manure composting with adding magnesium chloride. These results indicated that in the end of thermophilic stage of composting, the ammonia nitrogen losses of the piles with the intermittent aeration and with continuous aeration, were 23.56 g and 56.98 g, respectively, which means the loss of ammonia nitrogen of swine composting by the intermittent aeration was just 41.35% of that by the continuous aeration. Such loss of ammonia nitrogen resulted in 9.8% higher of the total kjeldahl nitrogen (TKN) concentration in the pile with the intermittent aeration than that with the continuous aeration. No significant difference occurred between two piles in orthophosphate, sequential extraction phosphorus and the total phosphorus (TP). However, in the pile with intermittent aeration, the percentage of the easily dissolved phosphorous forms such as H2O-P and NaHCO3-P was increased from 27.6% of TP to 66.5%, and the other pile from 27.6% to 64.9%. The TP concentrations in both piles were 17.2 g/kg in the end of thermophilic composting stage. The mixed crystals containing magnesium and phosphorus were formed in both piles of swine composting.

  17. Evaluation of re-aeration equations for river Ghataprabha, Karnataka, India and development of refined equation.

    PubMed

    Kalburgi, P B; Jha, R; Ojha, C S P; Deshannavar, U B

    2015-01-01

    Stream re-aeration is an extremely important component to enhance the self-purification capacity of streams. To estimate the dissolved oxygen (DO) present in the river, estimation of re-aeration coefficient is mandatory. Normally, the re-aeration coefficient is expressed as a function of several stream variables, such as mean stream velocity, shear stress velocity, bed slope, flow depth and Froude number. Many empirical equations have been developed in the last years. In this work, 13 most popular empirical re-aeration equations, used for re-aeration prediction, have been tested for their applicability in Ghataprabha River system, Karnataka, India, at various locations. Extensive field data were collected during the period March 2008 to February 2009 from seven different sites located in the river to observe re-aeration coefficient using mass balance approach. The performance of re-aeration equations have been evaluated using various error estimations, namely, the standard error (SE), mean multiplicative error (MME), normalized mean error (NME) and correlation statistics. The results show that the predictive equation developed by Jha et al. (Refinement of predictive re-aeration equations for a typical Indian river. Hydrological Process. 2001;15(6):1047-1060), for a typical Indian river, yielded the best agreement with the values of SE, MME, NME and correlation coefficient r. Furthermore, a refined predictive equation has been developed for river Ghataprabha using least-squares algorithm that minimizes the error estimates.

  18. Epidemiology of Lung Cancer.

    PubMed

    Schwartz, Ann G; Cote, Michele L

    2016-01-01

    Lung cancer continues to be one of the most common causes of cancer death despite understanding the major cause of the disease: cigarette smoking. Smoking increases lung cancer risk 5- to 10-fold with a clear dose-response relationship. Exposure to environmental tobacco smoke among nonsmokers increases lung cancer risk about 20%. Risks for marijuana and hookah use, and the new e-cigarettes, are yet to be consistently defined and will be important areas for continued research as use of these products increases. Other known environmental risk factors include exposures to radon, asbestos, diesel, and ionizing radiation. Host factors have also been associated with lung cancer risk, including family history of lung cancer, history of chronic obstructive pulmonary disease and infections. Studies to identify genes associated with lung cancer susceptibility have consistently identified chromosomal regions on 15q25, 6p21 and 5p15 associated with lung cancer risk. Risk prediction models for lung cancer typically include age, sex, cigarette smoking intensity and/or duration, medical history, and occupational exposures, however there is not yet a risk prediction model currently recommended for general use. As lung cancer screening becomes more widespread, a validated model will be needed to better define risk groups to inform screening guidelines. PMID:26667337

  19. Donor management and lung preservation for lung transplantation.

    PubMed

    Munshi, Laveena; Keshavjee, Shaf; Cypel, Marcelo

    2013-06-01

    Although lung transplantation has become a life-saving option for patients with end-stage lung disease, this intervention is hampered by a shortage of lungs in view of the growing number of people on the waiting list. Lungs are retrieved from only a small percentage of multiorgan donors, and the transplantation and intensive-care communities have recognised the need to develop innovative methods to expand the donor pool. Advancements in lung-preservation techniques in the preretrieval and postretrieval periods have increased the pool of available donors, and novel research and discoveries in this area have steadily improved post-transplantation adverse events. This Review summarises current best practice and the latest research on intensive-care management of a potential lung donor. We also discuss lung-preservation techniques, including advancements in normothermic ex-vivo lung perfusion, and the potential for a personalised medicine approach to the organ. PMID:24429157

  20. Effects of intermittent aeration on pollutants removal in subsurface wastewater infiltration system.

    PubMed

    Pan, Jing; Fei, Hexin; Song, Siyu; Yuan, Fang; Yu, Long

    2015-09-01

    In this study, the pollutant removal performances in two pilot-scale subsurface wastewater infiltration systems (SWISs) with and without intermittent aeration were investigated. Matrix oxidation reduction potential (ORP) results showed that intermittent aeration well developed aerobic conditions in upper matrix and anoxic or anaerobic conditions in the subsequent sections, which resulted in high NH4(+)-N and TN removal. Moreover, intermittent aeration increased removal rates of COD and TP. Microbial populations and enzyme activities analysis proved that intermittent aeration not only obviously boosted the growth and reproduction of bacteria, fungus, actinomyces, nitrifying bacteria and denitrifying bacteria, but also successfully increased nitrate reductase (NR) and nitrite reductase (NIR) in the depth of 80 and 110 cm. The results suggest that the intermittent aeration could be a widespread research and application strategy for achieving the high removal performance in SWISs.

  1. Computational study on microscale behavior of bubble generated by aeration in a plug-flow aeration tank.

    PubMed

    Wang, Huanran; Li, Yanpeng; Zhao, Zhixin

    2009-01-01

    The microscale hydrodynamics of bubbles generated by aeration is directly related to the oxygen transfer efficiency and the overall performance of the activated sludge wastewater treatment process. To gain a deeper insight on the microscale phenomena of dispersed bubble occurring in this process, a three-dimensional direct simulation method is developed to study the effects of the liquid cross-flow on microscale behavior of bubble generation in a plug-flow aeration tank. The numerical simulations are performed using the level set method coupling with the governing equations of a single fluid with variable properties. The governing equations are solved using the finite-volume technique. The simulation results are validated through comparison with experimental observations. The study indicates that the liquid cross-flow has a strong impact on the bubble generation. Compared to that generated under quiescent liquid conditions, the bubble under liquid cross-flow conditions grows downstream along the tilted axis. The bubble generation time tends to decrease noticeably and the bubble at detachment has significantly smaller size. The bubble size and generation time also increase with the increase of gas velocity. The relation of such results to the oxygen transfer efficiency of the wastewater treatment process is also discussed.

  2. Reduction in organic effluent static acute toxicity to fathead minnows by various aeration techniques.

    PubMed

    Belanger, S E; Farris, J L; Cherry, D S

    1988-01-01

    This study compared results of no aeration, intermittent aeration, and constant aeration strategies in determining the static acute (48-h) toxicity of phenolic-based effluents to adult fathead minnows (Pimephales promelas). Toxicity was greatest in no aeration tests followed by intermittent aeration and constant aeration. Two factors were considered responsible for the observed patterns of toxicity. First, in side-by-side tests of no versus intermittent aeration and intermittent versus constant aeration, toxicity reductions were directly attributed to maintenance of dissolved oxygen above 5.0 mg litre(-1) in aerated containers. Secondly, toxicity was reduced when treatment system temperatures were warmest, probably due to increased microbial activity and volatilisation during late spring to early autumn (temperatures > 16 degrees C). Effluent was slightly more toxic on- than off-site, presumably due to degradation of phenolic compounds during transport and set-up at the off-site laboratory (approximately 4.5 h). Gill tissue ultrastructure and histopathology were used to determine the extent of effluent-induced damage and the recovery of minnows to short (6-h) effluent exposures. After a 48-h exposure to the approximate LC(50) level, gill tissue lamellae were characteristically desquamated with epithelium lifting from the basement membrane. Gill tissue was similarly damaged after a 6-h exposure to 100% effluent and had recovered to pre-exposure conditions after 42 h in clean water. Aeration strategies in these studies demonstrated potential air-stripping of volatile compounds, although stress to test organisms from low dissolved oxygen was relieved.

  3. [Optimization and comparison of nitrogen and phosphorus removal by different aeration modes in oxidation ditch].

    PubMed

    Guo, Chang-Zi; Peng, Dang-Cong; Cheng, Xue-Mei; Wang, Dan

    2012-03-01

    The oxidation ditch operation mode was simulated by sequencing batch reactor (SBR) system with alternate stirring and aeration. The nitrogen and phosphorus removal efficiencies were investigated in two different aeration modes: point aeration and step aeration. Experimental results show that oxygen is dissolved more efficiently in point aeration mode with a longer aerobic region in the same air supply capacity, but dissolved oxygen (DO) utilization efficiency for nitrogen and phosphorus removal is high in step aeration mode. Nitrification abilities of the two modes are equal with ammonia-nitrogen (NH4(+) -N) removal efficiency of 96.68% and 97.03%, respectively. Nitrifier activities are 4.65 and 4.66 mg x (g x h)(-1) respectively. When the ratio of anoxic zones and the aerobic zones were 1, the total nitrogen (TN) removal efficiency of point aeration mode in 2, 4 or 7 partitions was respectively 60.14%, 47.93% and 33.7%. The total phosphorus (TP) removal efficiency was respectively 28.96%, 23.75% and 24.31%. The less the partitions, the higher the nitrogen and phosphorus removal efficiencies, but it is in more favor of TN removal. As for step aeration mode with only one partitioning zone, the TN and TP removal efficiencies are respectively 64.21% and 49.09%, which is better than in point aeration mode, but more conducive to the improvement of TP removal efficiency. Under the condition of sufficient nitrification in step aeration mode, the nitrogen and phosphorus removal is better with the increase of anoxic zone. The removal efficiencies of TN and TP respectively rose to 73.94% and 54.18% when the ratio of anoxic zones and the aerobic zones was increased from 1 : 1 to 1. 8 : 1. As the proportion of anoxic zones was enlarged further, nitrification and operation stability were weakened so as to affect the nitrogen and phosphorus removal efficiencies.

  4. Cracking in autoclaved aerated concrete: Experimental investigation and XFEM modeling

    SciTech Connect

    Ferretti, D.

    2015-01-15

    The paper aims to investigate and model cracking development in beams and deep-beams made of autoclaved aerated concrete (AAC). Fracture mechanics of AAC has been first studied by performing three-point bending tests on beams, similar to those commonly used for ordinary concrete elements. In some of these tests, crack growth has been also monitored by using ESPI laser technique. In this way, it has been possible to calibrate the main parameters of a proper cohesive law by means of extended finite element inverse analysis. Subsequently, cracking tests have been also performed on deep-beams, whose behavior is more representative of full scale walls. To validate the proposed cohesive law, deep-beam experimental behavior has been finally simulated through XFEM.

  5. Methane biofiltration using autoclaved aerated concrete as the carrier material.

    PubMed

    Ganendra, Giovanni; Mercado-Garcia, Daniel; Hernandez-Sanabria, Emma; Boeckx, Pascal; Ho, Adrian; Boon, Nico

    2015-09-01

    The methane removal capacity of mixed methane-oxidizing bacteria (MOB) culture in a biofilter setup using autoclaved aerated concrete (AAC) as a highly porous carrier material was tested. Batch experiment was performed to optimize MOB immobilization on AAC specimens where optimum methane removal was obtained when calcium chloride was not added during bacterial inoculation step and 10-mm-thick AAC specimens were used. The immobilized MOB could remove methane at low concentration (~1000 ppmv) in a biofilter setup for 127 days at average removal efficiency (RE) of 28.7 %. Unlike a plug flow reactor, increasing the total volume of the filter by adding a biofilter in series did not result in higher total RE. MOB also exhibited a higher abundance at the bottom of the filter, in proximity with the methane gas inlet where a high methane concentration was found. Overall, an efficient methane biofilter performance could be obtained using AAC as the carrier material.

  6. Methane biofiltration using autoclaved aerated concrete as the carrier material.

    PubMed

    Ganendra, Giovanni; Mercado-Garcia, Daniel; Hernandez-Sanabria, Emma; Boeckx, Pascal; Ho, Adrian; Boon, Nico

    2015-09-01

    The methane removal capacity of mixed methane-oxidizing bacteria (MOB) culture in a biofilter setup using autoclaved aerated concrete (AAC) as a highly porous carrier material was tested. Batch experiment was performed to optimize MOB immobilization on AAC specimens where optimum methane removal was obtained when calcium chloride was not added during bacterial inoculation step and 10-mm-thick AAC specimens were used. The immobilized MOB could remove methane at low concentration (~1000 ppmv) in a biofilter setup for 127 days at average removal efficiency (RE) of 28.7 %. Unlike a plug flow reactor, increasing the total volume of the filter by adding a biofilter in series did not result in higher total RE. MOB also exhibited a higher abundance at the bottom of the filter, in proximity with the methane gas inlet where a high methane concentration was found. Overall, an efficient methane biofilter performance could be obtained using AAC as the carrier material. PMID:25967655

  7. [Effects of substrate-aeration cultivation pattern on tomato growth].

    PubMed

    Zhao, Xu; Li, Tian-Lai; Sun, Zhou-Ping

    2010-01-01

    Aeroponics can increase the fruit yield of tomato plant, but its cost is very high. In this paper, tomato seedlings were planted with three cultures, i. e., whole perlite culture (CK), perlite-aeration culture (T1), and aeroponics (T2), and a comparative study was made on the seedlings growth. Compared with CK, T1 improved the gas environment in root zone significantly, with the CO2 and O2 concentrations in root zone being 0.2 and 1.17 times higher, and increased the plant height and stem diameter after 60 days of transplanting by 5.1% and 8.4%, respectively. The plant net photosynthetic rate of T1 was significantly higher than that of CK, with the maximum value after transplanting 45 days increased by 13%. T1 also increased the root activity and ion absorbing ability significantly, with the root activity after transplanting 45 days being 1.23 times of CK, and the root K, Ca, and Mg contents after transplanting 60 days increased by 31%, 37%, and 27%, respectively. The fruit yield of T1 was 1.16 times of CK. No significant differences in these indices were observed between T1 and T2, and less difference in the fruit soluble sugar and organic acid contents as well as the sugar-acid ratio was found among CK, T1, and T2. It was suggested that perlite-aeration cultivation pattern was an easy and feasible way to markedly improve the fruit yield of tomato plant. PMID:20387426

  8. [Effects of substrate-aeration cultivation pattern on tomato growth].

    PubMed

    Zhao, Xu; Li, Tian-Lai; Sun, Zhou-Ping

    2010-01-01

    Aeroponics can increase the fruit yield of tomato plant, but its cost is very high. In this paper, tomato seedlings were planted with three cultures, i. e., whole perlite culture (CK), perlite-aeration culture (T1), and aeroponics (T2), and a comparative study was made on the seedlings growth. Compared with CK, T1 improved the gas environment in root zone significantly, with the CO2 and O2 concentrations in root zone being 0.2 and 1.17 times higher, and increased the plant height and stem diameter after 60 days of transplanting by 5.1% and 8.4%, respectively. The plant net photosynthetic rate of T1 was significantly higher than that of CK, with the maximum value after transplanting 45 days increased by 13%. T1 also increased the root activity and ion absorbing ability significantly, with the root activity after transplanting 45 days being 1.23 times of CK, and the root K, Ca, and Mg contents after transplanting 60 days increased by 31%, 37%, and 27%, respectively. The fruit yield of T1 was 1.16 times of CK. No significant differences in these indices were observed between T1 and T2, and less difference in the fruit soluble sugar and organic acid contents as well as the sugar-acid ratio was found among CK, T1, and T2. It was suggested that perlite-aeration cultivation pattern was an easy and feasible way to markedly improve the fruit yield of tomato plant.

  9. Effects of loading rate and aeration on nitrogen removal and N2O emissions in intermittently aerated sequencing batch reactors treating slaughterhouse wastewater at 11 °C.

    PubMed

    Pan, Min; Hu, Zhenhu; Liu, Rui; Zhan, Xinmin

    2015-04-01

    This study aimed to find optimal operation conditions for nitrogen removal from high strength slaughterhouse wastewater at 11 °C using the intermittently aerated sequencing batch reactors (IASBRs) so as to provide an engineering control strategy for the IASBR technology. Two operational parameters were examined: (1) loading rates and (2) aeration rates. Both the two parameters affected variation of DO concentrations in the IASBR operation cycles. It was found that to achieve efficient nitrogen removal via partial nitrification-denitrification (PND), "DO elbow" point must appear at the end of the last aeration period. There was a correlation between the ammonium oxidizing bacteria (AOB)/nitrite oxidizing bacteria (NOB) ratio and the average DO concentrations in the last aeration periods; when the average DO concentrations in the last aeration periods were lower than 4.86 mg/L, AOB became the dominant nitrifier population, which benefited nitrogen removal via PND. Both the nitrogen loading rate and the aeration rate influenced the population sizes of AOB and NOB. To accomplish efficient nitrogen removal via PND, the optimum aeration rate (A, L air/min) applied can be predicted according to the average organic loading rates based on mathematical equations developed in this study. The research shows that the amount of N2O generation in the aeration period was reduced with increasing the aeration rate; however, the highest N2O generation in the non-aeration period was observed at the optimum aeration rates.

  10. Ammonia-based feedforward and feedback aeration control in activated sludge processes.

    PubMed

    Rieger, Leiv; Jones, Richard M; Dold, Peter L; Bott, Charles B

    2014-01-01

    Aeration control at wastewater treatment plants based on ammonia as the controlled variable is applied for one of two reasons: (1) to reduce aeration costs, or (2) to reduce peaks in effluent ammonia. Aeration limitation has proven to result in significant energy savings, may reduce external carbon addition, and can improve denitrification and biological phosphorus (bio-P) performance. Ammonia control for limiting aeration has been based mainly on feedback control to constrain complete nitrification by maintaining approximately one to two milligrams of nitrogen per liter of ammonia in the effluent. Increased attention has been given to feedforward ammonia control, where aeration control is based on monitoring influent ammonia load. Typically, the intent is to anticipate the impact of sudden load changes, and thereby reduce effluent ammonia peaks. This paper evaluates the fundamentals of ammonia control with a primary focus on feedforward control concepts. A case study discussion is presented that reviews different ammonia-based control approaches. In most instances, feedback control meets the objectives for both aeration limitation and containment of effluent ammonia peaks. Feedforward control, applied specifically for switching aeration on or off in swing zones, can be beneficial when the plant encounters particularly unusual influent disturbances.

  11. Influence of aeration intensity on mature aerobic granules in sequencing batch reactor.

    PubMed

    Gao, Da-Wen; Liu, Lin; Liang, Hong

    2013-05-01

    Aeration intensity is well known as an important factor in the formation of aerobic granules. In this research, two identical lab-scale sequencing batch reactors with aeration intensity of 0.8 (R1) and 0.2 m(3)/h (R2) were operated to investigate the characteristics and kinetics of matured aerobic granules. Results showed that both aeration intensity conditions induced granulation, but they showed different effects on the characteristics of aerobic granules. Compared with the low aeration intensity (R2), the aerobic granules under the higher aeration intensity (R1) had better physical characteristics and settling ability. However, the observed biomass yield (Y obs) in R1 [0.673 kg mixed liquor volatile suspended solids (MLVSS)/kg chemical oxygen demand (COD)] was lower than R2 (0.749 kg MLVSS/kg COD). In addition, the maximum specific COD removal rates (q max) and apparent half rate constant (K) of mature aerobic granular sludge under the two aeration intensities were at a similar level. Therefore, the matured aerobic granule system does not require to be operated in a higher aeration intensity, which will reduce the energy consumption.

  12. Demonstration of membrane aeration panels: City of Geneva Wastewater Treatment Plant. Final report

    SciTech Connect

    1995-01-01

    This report describes the design, construction, and testing of membrane aeration panels at the Marsh Creek wastewater treatment plant (WWTP) in Geneva, NY. The operators at the Geneva plant have undertaken a long-term program to upgrade wastewater treatment processes and lower operating costs. The aging mechanical surface aerators at the Marsh Creek treatment plant were replaced by a state-of-the-art membrane panel system. This fine-bubble diffused air system offers higher oxygen transfer efficiency than surface aerators or other types of fine-bubble diffused-air systems. The project had four objectives: to decrease the amount of electricity used at the plant for aeration; to enable the plant`s existing aeration basins to accommodate higher organic loads and/or nitrify the wastewater should the need arise; to provide an even distribution of dissolved oxygen within the aeration basins to enhance biological wastewater treatment activity; and to provide technical data to assess the performance of the membrane panel system versus other forms of wastewater aeration.

  13. Effects of aeration and natural zeolite on ammonium removal during the treatment of sewage by mesocosm-scale constructed wetlands.

    PubMed

    Araya, F; Vera, I; Sáez, K; Vidal, G

    2016-01-01

    The objective was to evaluate the effects of intermittent artificial aeration cycles and natural zeolite as a support medium, in addition to the contribution of plants (Schoenoplectus californicus) on NH4(+)-N removal during sewage treatment by Constructed Wetlands (CW). Two lines of Mesocosm Constructed Wetland (MCW) were installed: (a) gravel line (i.e. G-Line) and (b) zeolite line (i.e. Z-Line). Aeration increased the NH4(+)-N removal efficiency by 20-45% in the G-Line. Natural zeolite increased the NH4(+)-N removal efficiency by up to 60% in the Z-Line. Plants contributed 15-30% of the NH4(+)-N removal efficiency and no difference between the G-Line and the Z-Line. Conversely, the NH4(+)-N removal rate was shown to only increase with the use of natural zeolite. However, the MCW with natural zeolite, the NH4(+)-N removal rate showed a direct relationship only with the NH4(+)-N influent concentration. Additionally, relationship between the oxygen, energy and area regarding the NH4(+)-N removal efficiency was established for 2.5-12.5 gO2/(kWh-m(2)) in the G-Line and 0.1-2.6 gO2/(kWh-m(2)) in the Z-Line. Finally, it was established that a combination of natural zeolite as a support medium and the aeration strategy in a single CW could regenerate the zeolite's adsorption sites and maintain a given NH4(+)-N removal efficiency over time.

  14. Aeration of the teuftal landfill: Field scale concept and lab scale simulation.

    PubMed

    Ritzkowski, Marco; Walker, Beat; Kuchta, Kerstin; Raga, Roberto; Stegmann, Rainer

    2016-09-01

    Long lasting post-closure care (PCC) is often the major financial burden for operators of municipal solid waste (MSW) landfills. Beside costs for the installation and maintenance of technical equipment and barriers, in particular long term treatment of leachate and landfill gas has to be paid from capital surplus. Estimations based on laboratory experiments project time periods of many decades until leachate quality allows for direct discharge (i.e. no need for further purification). Projections based on leachate samples derived from the last 37years for 35 German landfills confirm these assumption. Moreover, the data illustrate that in particular ammonium nitrogen concentrations are likely to fall below limit values only after a period of 300years. In order to avoid long lasting PCC the operator of Teuftal landfill, located in the Swiss canton Bern, decided to biologically stabilize the landfill by means of a combined in situ aeration and moisturization approach. In December 2014 the aeration started at a landfill section containing approximately 30% of the total landfill volume. From summer 2016 onwards the remaining part of the landfill will be aerated. Landfill aeration through horizontal gas and leachate drains is carried out for the first time in field scale in Europe. The technical concept is described in the paper. Parallel to field scale aeration, investigations for the carbon and nitrogen turnover are carried out by means of both simulated aerated landfills and simulated anaerobic landfills. The results presented in this paper demonstrate that aeration is capable to enhance, both carbon mobilization and discharge via the gas phase. This effect comes along with a significant increase in bio-stabilization of the waste organic fraction, which positively affects the landfill emission behavior in the long run. In terms of leachate pollution reduction it could be demonstrated that the organic load decrease fast and widely independent of the adjusted aeration

  15. Aeration of the teuftal landfill: Field scale concept and lab scale simulation.

    PubMed

    Ritzkowski, Marco; Walker, Beat; Kuchta, Kerstin; Raga, Roberto; Stegmann, Rainer

    2016-09-01

    Long lasting post-closure care (PCC) is often the major financial burden for operators of municipal solid waste (MSW) landfills. Beside costs for the installation and maintenance of technical equipment and barriers, in particular long term treatment of leachate and landfill gas has to be paid from capital surplus. Estimations based on laboratory experiments project time periods of many decades until leachate quality allows for direct discharge (i.e. no need for further purification). Projections based on leachate samples derived from the last 37years for 35 German landfills confirm these assumption. Moreover, the data illustrate that in particular ammonium nitrogen concentrations are likely to fall below limit values only after a period of 300years. In order to avoid long lasting PCC the operator of Teuftal landfill, located in the Swiss canton Bern, decided to biologically stabilize the landfill by means of a combined in situ aeration and moisturization approach. In December 2014 the aeration started at a landfill section containing approximately 30% of the total landfill volume. From summer 2016 onwards the remaining part of the landfill will be aerated. Landfill aeration through horizontal gas and leachate drains is carried out for the first time in field scale in Europe. The technical concept is described in the paper. Parallel to field scale aeration, investigations for the carbon and nitrogen turnover are carried out by means of both simulated aerated landfills and simulated anaerobic landfills. The results presented in this paper demonstrate that aeration is capable to enhance, both carbon mobilization and discharge via the gas phase. This effect comes along with a significant increase in bio-stabilization of the waste organic fraction, which positively affects the landfill emission behavior in the long run. In terms of leachate pollution reduction it could be demonstrated that the organic load decrease fast and widely independent of the adjusted aeration

  16. Lung transplant

    MedlinePlus

    Solid organ transplant - lung ... the new lung Have severe disease of other organs Cannot reliably take their medicines Are unable to ... medicines Damage to your kidneys, liver, or other organs from anti-rejection medicines Future risk of certain ...

  17. Lung surgery

    MedlinePlus

    ... Pneumonectomy; Lobectomy; Lung biopsy; Thoracoscopy; Video-assisted thoracoscopic surgery; VATS ... You will have general anesthesia before surgery. You will be asleep and unable to feel pain. Two common ways to do surgery on your lungs are thoracotomy and video- ...

  18. Aeration remediation of a polluted waterway increases near-surface coarse and culturable microbial aerosols.

    PubMed

    Dueker, M Elias; O'Mullan, Gregory D

    2014-04-15

    Aeration remediation is currently used in polluted urban waterways to increase oxygen levels in the water column. Recent studies have provided increasing evidence that the bursting of bubbles at water surfaces introduced by aeration, or other surface disturbances, can transfer viable bacteria to the air. In heavily sewage-polluted waterways these water-originated bacterial aerosols may pose as a health risk to recreators in small boats or residents inhabiting the shoreline. Nonetheless, few studies have explored aerosols above active aeration remediation projects in waterways or investigated how bacterial aerosols change with vertical distance from aeration activities. This study, conducted at the Newtown Creek superfund site in Brooklyn, NY, USA, measured coarse aerosol particles and culturable bacteria in near-surface air above waters undergoing aeration remediation. Regardless of aeration operation culturable bacterial fallout was greater near-surface (0.6m above water) than previously-reported measurements made at 2.5m. Molecular analysis of the 16S rRNA gene sequences from isolated bacteria demonstrates that water and air shared a large number of bacterial genera and that the genera present in the near-surface aerosols (0.6m) contained water-associated Vibrio and Caulobacter, which were not present at 2.5m, despite the smaller sequence library size from the near-surface. Also, the near-surface microbial assemblage had significantly greater association with sequences detected previously in aquatic environments compared to the 2.5m library. We found compelling evidence that aeration activity contributed to this vertical gradient in bacterial aerosol concentrations and identity. Similar to results from 2.5m, concentrations of near-surface respirable coarse aerosols (<10 um) increased significantly when aeration was occurring. Culturable bacterial aerosol fallout was also greater near-surface when the aerator was on compared to simultaneous measurements made at 2

  19. Improving microalgal growth with reduced diameters of aeration bubbles and enhanced mass transfer of solution in an oscillating flow field.

    PubMed

    Yang, Zongbo; Cheng, Jun; Lin, Richen; Zhou, Junhu; Cen, Kefa

    2016-07-01

    A novel oscillating gas aerator combined with an oscillating baffle was proposed to generate smaller aeration bubbles and enhance solution mass transfer, which can improve microalgal growth in a raceway pond. A high-speed photography system (HSP) was used to measure bubble diameter and generation time, and online precise dissolved oxygen probes and pH probes were used to measure mass-transfer coefficient and mixing time. Bubble diameter and generation time decreased with decreased aeration gas rate, decreased orifice diameter, and increased water velocity in the oscillating gas aerator. The optimized oscillating gas aerator decreased bubble diameter and generation time by 25% and 58%, respectively, compared with a horizontal tubular gas aerator. Using an oscillating gas aerator and an oscillating baffle in a raceway pond increased the solution mass-transfer coefficient by 15% and decreased mixing time by 32%; consequently, microalgal biomass yield increased by 19%. PMID:27035474

  20. Improving microalgal growth with reduced diameters of aeration bubbles and enhanced mass transfer of solution in an oscillating flow field.

    PubMed

    Yang, Zongbo; Cheng, Jun; Lin, Richen; Zhou, Junhu; Cen, Kefa

    2016-07-01

    A novel oscillating gas aerator combined with an oscillating baffle was proposed to generate smaller aeration bubbles and enhance solution mass transfer, which can improve microalgal growth in a raceway pond. A high-speed photography system (HSP) was used to measure bubble diameter and generation time, and online precise dissolved oxygen probes and pH probes were used to measure mass-transfer coefficient and mixing time. Bubble diameter and generation time decreased with decreased aeration gas rate, decreased orifice diameter, and increased water velocity in the oscillating gas aerator. The optimized oscillating gas aerator decreased bubble diameter and generation time by 25% and 58%, respectively, compared with a horizontal tubular gas aerator. Using an oscillating gas aerator and an oscillating baffle in a raceway pond increased the solution mass-transfer coefficient by 15% and decreased mixing time by 32%; consequently, microalgal biomass yield increased by 19%.

  1. Micro-aeration for hydrogen sulfide removal from biogas

    NASA Astrophysics Data System (ADS)

    Duangmanee, Thanapong

    The presence of sulfur compounds (e.g. protein, sulfate, thiosulfate, sulfite, etc.) in the feed stream generates highly corrosive and odorous hydrogen sulfide during anaerobic digestion. The high sulfide level in the biogas stream is not only poisonous to many novel metal catalysts employed in thermo-catalytic processes but also reduces the quality of methane to produce renewable energy. This study used an innovative, low-maintenance, low-cost biological sulfide removal technology to remove sulfides simultaneously from both gas and liquid phase. ORP (Oxidation-Reduction-Potential) was used as the controlling parameter to precisely regulate air injection to the sulfide oxidizing unit (SOU). The microaeration technique provided just enough oxygen to partially oxidize sulfides to elemental sulfur without inhibiting methanogenesis. The SOU was equipped with a diffuser at the bottom for the dispersion of sulfide-laden biogas and injected air throughout the column. The SOU can be operated as a standalone unit or coupled with an anaerobic digester to simultaneously remove sulfide from the biogas and effluent. The integrated system was capable of reducing hydrogen sulfide in biogas from 2,450 to less than 2 ppmV with minimal sulfate production at the highest available sulfide loading rate of 0.24 kg/m3-day. More than 98% of sulfide removed was recovered as elemental sulfur. However, the standalone SOU was able to operate at high hydrogen sulfide loading of 1.46 kg/m 3-day at inlet sulfide concentration of 3000 ppmV and reduce the off-gas hydrogen sulfide concentrations to less than 10 ppmV. The experiment also revealed that the ORP controlled aeration was sensitive enough to prevent oxygen overdosing (dampening effect) during unexpected surges of aeration. Using generalized linear regression, a model predicting output H2S concentration based on input H2S concentrations, SOU medium heights, and biogas flow rates, was derived. With 95% confidence, output H2S concentration

  2. Lung Organogenesis

    PubMed Central

    Warburton, David; El-Hashash, Ahmed; Carraro, Gianni; Tiozzo, Caterina; Sala, Frederic; Rogers, Orquidea; De Langhe, Stijn; Kemp, Paul J.; Riccardi, Daniela; Torday, John; Bellusci, Saverio; Shi, Wei; Lubkin, Sharon R; Jesudason, Edwin

    2011-01-01

    Developmental lung biology is a field that has the potential for significant human impact: lung disease at the extremes of age continues to cause major morbidity and mortality worldwide. Understanding how the lung develops holds the promise that investigators can use this knowledge to aid lung repair and regeneration. In the decade since the “molecular embryology” of the lung was first comprehensively reviewed, new challenges have emerged—and it is on these that we focus the current review. Firstly, there is a critical need to understand the progenitor cell biology of the lung in order to exploit the potential of stem cells for the treatment of lung disease. Secondly, the current familiar descriptions of lung morphogenesis governed by growth and transcription factors need to be elaborated upon with the reinclusion and reconsideration of other factors, such as mechanics, in lung growth. Thirdly, efforts to parse the finer detail of lung bud signaling may need to be combined with broader consideration of overarching mechanisms that may be therapeutically easier to target: in this arena, we advance the proposal that looking at the lung in general (and branching in particular) in terms of clocks may yield unexpected benefits. PMID:20691848

  3. Rapid Startup and Loading of an Attached Growth, Simultaneous Nitrification/Denitrification Membrane Aerated Bioreactor

    NASA Technical Reports Server (NTRS)

    Meyer, Caitlin; Vega, Leticia

    2014-01-01

    The Membrane Aerated Bioreactor (MABR) is an attached-growth biological system for simultaneous nitrification and denitrification. This design is an innovative approach to common terrestrial wastewater treatments for nitrogen and carbon removal. Implementing a biologically-based water treatment system for long-duration human exploration is an attractive, low energy alternative to physiochemical processes. Two obstacles to implementing such a system are (1) the "start-up" duration from inoculation to steady-state operations and (2) the amount of surface area needed for the biological activity to occur. The Advanced Water Recovery Systems (AWRS) team at JSC explored these two issues through two tests; a rapid inoculation study and a wastewater loading study. Results from these tests demonstrate that the duration from inoculation to steady state can be reduced to two weeks and that the surface area to volume ratio baseline used in the Alternative Water Processor (AWP) test was higher than what was needed to remove the organic carbon and ammonium from the system.

  4. Improving microalgal growth with small bubbles in a raceway pond with swing gas aerators.

    PubMed

    Yang, Zongbo; Cheng, Jun; Liu, Jianzhong; Zhou, Junhu; Cen, Kefa

    2016-09-01

    A novel swing gas aerator was developed to generate small bubbles for improving the mass transfer coefficient and microalgal growth rate in a raceway pond. A high-speed photography system (HSP) was used to measure the bubble diameter and generation time, and online precise dissolved oxygen probes and pH probes were used to measure the mass transfer coefficient and mixing time. Bubble generation time and diameter decreased by 21% and 9%, respectively, when rubber gas aerators were swung in the microalgae solution. When water pump power and gas aeration rate increased in a raceway pond with swing gas aerators and oscillating baffles (SGAOB), bubble generation time and diameter decreased but solution velocity and mass transfer coefficient increased. The mass transfer coefficient increased by 25% and the solution velocity increased by 11% when SGAOB was used, and the microalgal biomass yield increased by 18%.

  5. Survival of Salmonella enterica in Aerated and Nonaerated Wastewaters from Dairy Lagoons

    PubMed Central

    Ravva, Subbarao V.; Sarreal, Chester Z.

    2014-01-01

    Salmonella is the most commonly identified foodborne pathogen in produce, meat and poultry. Cattle are known reservoirs of Salmonella and the pathogen excreted in feces ends up in manure flush lagoons. Salmonella enterica survival was monitored in wastewater from on-site holding lagoons equipped or not with circulating aerators at two dairies. All strains had poor survival rates and none proliferated in waters from aerated or settling lagoons. Populations of all three Salmonella serovars declined rapidly with decimal reduction times (D) of <2 days in aerated microcosms prepared from lagoon equipped with circulators. Populations of Salmonella decreased significantly in aerated microcosms (D = 4.2 d) compared to nonaerated waters (D = 7.4 d) and in summer (D = 3.4 d) compared to winter (D = 9.0 d). We propose holding the wastewater for sufficient decimal reduction cycles in lagoons to yield pathogen-free nutrient-rich water for crop irrigations and fertilization. PMID:25358096

  6. Improved design and optimization of aeration control for WWTPs by dynamic simulation.

    PubMed

    Alex, J; To, T Binh; Hartwig, P

    2002-01-01

    This paper introduces a model library based on the simulation environment MATLAB/SIMULINK which allows the simulation of the aeration system of an wastewater treatment plant (WWTP). The model library presented covers all parts of an aeration system starting with the compressor set over the common air rail, flow resistances through pipes, controllable valves, aeration membranes and ending last not least with the controllers involved. The main objective of the development of the simulation system is the design, test and the support of the installation of more predictable and efficient control concepts for the aeration system in WWTPs. An example is given to demonstrate the application of the simulation system and to promote a control scheme with a flexible reference value for the pressure at the common air rail based on a most open valve (MOV) concept.

  7. Survival of Salmonella enterica in aerated and nonaerated wastewaters from dairy lagoons.

    PubMed

    Ravva, Subbarao V; Sarreal, Chester Z

    2014-11-01

    Salmonella is the most commonly identified foodborne pathogen in produce, meat and poultry. Cattle are known reservoirs of Salmonella and the pathogen excreted in feces ends up in manure flush lagoons. Salmonella enterica survival was monitored in wastewater from on-site holding lagoons equipped or not with circulating aerators at two dairies. All strains had poor survival rates and none proliferated in waters from aerated or settling lagoons. Populations of all three Salmonella serovars declined rapidly with decimal reduction times (D) of <2 days in aerated microcosms prepared from lagoon equipped with circulators. Populations of Salmonella decreased significantly in aerated microcosms (D = 4.2 d) compared to nonaerated waters (D = 7.4 d) and in summer (D = 3.4 d) compared to winter (D = 9.0 d). We propose holding the wastewater for sufficient decimal reduction cycles in lagoons to yield pathogen-free nutrient-rich water for crop irrigations and fertilization. PMID:25358096

  8. Survival of Salmonella enterica in aerated and nonaerated wastewaters from dairy lagoons.

    PubMed

    Ravva, Subbarao V; Sarreal, Chester Z

    2014-10-29

    Salmonella is the most commonly identified foodborne pathogen in produce, meat and poultry. Cattle are known reservoirs of Salmonella and the pathogen excreted in feces ends up in manure flush lagoons. Salmonella enterica survival was monitored in wastewater from on-site holding lagoons equipped or not with circulating aerators at two dairies. All strains had poor survival rates and none proliferated in waters from aerated or settling lagoons. Populations of all three Salmonella serovars declined rapidly with decimal reduction times (D) of <2 days in aerated microcosms prepared from lagoon equipped with circulators. Populations of Salmonella decreased significantly in aerated microcosms (D = 4.2 d) compared to nonaerated waters (D = 7.4 d) and in summer (D = 3.4 d) compared to winter (D = 9.0 d). We propose holding the wastewater for sufficient decimal reduction cycles in lagoons to yield pathogen-free nutrient-rich water for crop irrigations and fertilization.

  9. Improving microalgal growth with small bubbles in a raceway pond with swing gas aerators.

    PubMed

    Yang, Zongbo; Cheng, Jun; Liu, Jianzhong; Zhou, Junhu; Cen, Kefa

    2016-09-01

    A novel swing gas aerator was developed to generate small bubbles for improving the mass transfer coefficient and microalgal growth rate in a raceway pond. A high-speed photography system (HSP) was used to measure the bubble diameter and generation time, and online precise dissolved oxygen probes and pH probes were used to measure the mass transfer coefficient and mixing time. Bubble generation time and diameter decreased by 21% and 9%, respectively, when rubber gas aerators were swung in the microalgae solution. When water pump power and gas aeration rate increased in a raceway pond with swing gas aerators and oscillating baffles (SGAOB), bubble generation time and diameter decreased but solution velocity and mass transfer coefficient increased. The mass transfer coefficient increased by 25% and the solution velocity increased by 11% when SGAOB was used, and the microalgal biomass yield increased by 18%. PMID:27243604

  10. A rare case of esophageal lung in a neonate.

    PubMed

    Patil, Megharanjini; Sutagatti, Jagadish; Bhavikatti, Mohan; Nayak, Puneet V

    2016-01-01

    We report a rare case of esophageal lung in a neonate who presented with repeated chest infections and respiratory distress. Chest radiograph revealed increased opacification of the right lung with reduced lung volume and air bronchograms. Further evaluation with computed tomography (CT) showed the presence of only left mainstem bronchus at the tracheal bifurcation. Right mainstem bronchus originated from distal esophagus and aerated the right lung. Nasogastric tube was inserted into the stomach with injection of small amount of dilute barium through it, which established the communication of right mainstem bronchus with esophagus. Advanced CT scan imaging by virtual bronchoscopy and volume rendering further delineated the anatomical abnormality precisely prior to surgery. Surgical findings confirmed the diagnosis. PMID:27413267

  11. Application of membrane tubing aeration and perfluorocarbon To improve oxygen delivery to hairy root cultures

    PubMed

    Kanokwaree; Doran

    1998-05-01

    Growth and atropine production by Atropa belladonna hairy roots were studied in bioreactor cultures using porous polypropylene membrane tubing as a supplementary aeration device and with FC-43 perfluorocarbon emulsion added to the medium. Both these treatments were applied to improve oxygen transfer to the roots. Membrane tubing aeration allowed direct delivery of oxygen within the root clump, thus overcoming mass transfer resistances associated with poor intraclump penetration of liquid convective currents. Combined air sparging and membrane tubing aeration in a gas-driven bioreactor supported biomass levels 32-65% higher than sparging only of air or oxygen-enriched air at the same total gas flow rate. The optimal air flow rate ratio between the sparger and membrane tubing giving the maximum final biomass concentration was 0.2:0.4 L min-1. Intraclump dissolved oxygen tensions at high biomass densities were generally greater using air delivered by combined sparger-membrane tubing aeration than with sparging only of air or oxygen-enriched air. Specific atropine levels were not significantly affected by membrane tubing aeration. Indicators of anaerobic metabolism, such as lactic acid, ethanol, and ADH activity levels, were not significantly different in sparged and membrane-aerated systems; A. belladonna hairy roots also did not produce aerenchyma in response to oxygen limitations. Addition of perfluorocarbon emulsion to Murashige and Skoog medium in sparged stirred tank bioreactors did not improve growth, even when the emulsion was continuously recycled for re-aeration in an external vessel. Perfluorocarbons are associated with enhancement of gas-liquid oxygen transfer, so their ineffectiveness in this work most likely reflects the dominance of liquid-solid transfer resistances in hairy root cultures. The results of this investigation highlight the importance of developing new approaches for site-directed aeration of hairy root cultures, targeting oxygen delivery

  12. Modelisation of the contribution of sediments in the treatment process case of aerated lagoons.

    PubMed

    Jupsin, H; Vasel, J L

    2007-01-01

    In aerated lagoons and even more in stabilization ponds the specific power (W/m3) is not high enough to maintain all the suspended solids in suspension. Some part of the suspended solids (including biomass) settles directly into the reactor and not in the final settling pond. The gradual accumulation of those sediments on the pond bottom affects performance by reducing the pond volume and shortening the Hydraulic Residence Time. However, the role played by these deposits is not restricted to such a physical effect. Far from being inert sediments they are also an important oxygen sink that must be taken into account when designing aerator power and oxygen supply, for example. On the other hand, under aerobic conditions, the upper layer of sediments may contribute to the treatment as a biofilm compartment in the reactor. In aerated lagoon systems another process contributes to the interaction of deposits and the liquid phase: the operating (often sequencing) of aerators may induce a drastic resuspension of deposits. In a 3,000 m3 aerated lagoon we evaluated that 3 tons of deposits were resuspended when aerators were started. Due to those processes we consider that a mathematical model of an aerated lagoon or of a stabilization pond has to take into account the contribution (positive and negative aspects) of deposits in the process. In this paper we propose a model for sediments including production but also biological processes. Simulations of the aerated lagoon with or without the "sediment compartment" demonstrate the effect and the importance of this compartment on the process. Of course a similar approach could be used for facultative or even maturation ponds. The next step would be to include anaerobic activities in the bottom layer. PMID:17591192

  13. Nitrate-removal activity of a biofilm attached to a perlite carrier under continuous aeration conditions.

    PubMed

    Yamashita, Takahiro; Yokoyama, Hiroshi; Kanafusa, Sumiyo; Ogino, Akifumi; Ishida, Mitsuyoshi; Osada, Takashi; Tanaka, Yasuo

    2011-01-01

    The nitrate-removal activity of a biofilm attached to a perlite carrier from an aerobic bioreactor used for treating dairy farm wastewater was examined by batch experiments under continuous aeration conditions. Despite aeration, the biofilm removed nitrate at a rate of 114.4 mg-N/kg-perlite/h from wastewater containing cow milk and manure. In a clone library analysis of the biofilm, bacteria showing high similarity to the denitrifying bacteria Thauera spp. were detected.

  14. Photosynthetic aeration in biological wastewater treatment using immobilized microalgae-bacteria symbiosis.

    PubMed

    Praveen, Prashant; Loh, Kai-Chee

    2015-12-01

    Chlorella vulgaris encapsulated in alginate beads were added into a bioreactor treating synthetic wastewater using Pseudomonas putida. A symbiotic CO2/O2 gas exchange was established between the two microorganisms for photosynthetic aeration of wastewater. During batch operation, glucose removal efficiency in the bioreactor improved from 50% in 12 h without aeration to 100% in 6 h, when the bioreactor was aerated photosynthetically. During continuous operation, the bioreactor was operated at a low hydraulic retention time of 3.3 h at feed concentrations of 250 and 500 mg/L glucose. The removal efficiency at 500 mg/L increased from 73% without aeration to 100% in the presence of immobilized microalgae. The initial microalgae concentration was critical to achieve adequate aeration, and the removal rate increased with increasing microalgae concentration. The highest removal rate of 142 mg/L-h glucose was achieved at an initial microalgae concentration of 190 mg/L. Quantification of microalgae growth in the alginate beads indicated an exponential growth during symbiosis, indicating that the bioreactor performance was limited by oxygen production rates. Under symbiotic conditions, the chlorophyll content of the immobilized microalgae increased by more than 30%. These results indicate that immobilized microalgae in symbiosis with heterotrophic bacteria are promising in wastewater aeration. PMID:26266755

  15. Ecophysiology of wetland plant roots: A modelling comparison of aeration in relation to species distribution

    USGS Publications Warehouse

    Sorrell, B.K.; Mendelssohn, I.A.; McKee, K.L.; Woods, R.A.

    2000-01-01

    This study examined the potential for inter-specific differences in root aeration to determine wetland plant distribution in nature. We compared aeration in species that differ in the type of sediment and depth of water they colonize. Differences in root anatomy, structure and physiology were applied to aeration models that predicted the maximum possible aerobic lengths and development of anoxic zones in primary adventitious roots. Differences in anatomy and metabolism that provided higher axial fluxes of oxygen allowed deeper root growth in species that favour more reducing sediments and deeper water. Modelling identified factors that affected growth in anoxic soils through their effects on aeration. These included lateral root formation, which occurred at the expense of extension of the primary root because of the additional respiratory demand they imposed, reducing oxygen fluxes to the tip and stele, and the development of stelar anoxia. However, changes in sediment oxygen demand had little detectable effect on aeration in the primary roots due to their low wall permeability and high surface impedance, but appeared to reduce internal oxygen availability by accelerating loss from laterals. The development of pressurized convective gas flow in shoots and rhizomes was also found to be important in assisting root aeration, as it maintained higher basal oxygen concentrations at the rhizome-root junctions in species growing into deep water. (C) 2000 Annals of Botany Company.

  16. Improving hydrolysis acidification by limited aeration in the pretreatment of petrochemical wastewater.

    PubMed

    Wu, Changyong; Zhou, Yuexi; Wang, Peichao; Guo, Shujun

    2015-10-01

    Petrochemical wastewater was pretreated by hydrolysis acidification to improve the biodegradation and treatability on limited aeration conditions. The results showed limited aeration with DO from 0.2 to 0.3mg/L (average ORP was -210 mV) was the best condition. The BOD5/COD of influent was 0.23, and it increased to 0.43 on this condition. Limited aeration can obviously reduce the reduction of SO4(2-), reducing the generation of toxic gas H2S, and almost no H2S can be detected in the off-gas. The sulfate reducing bacteria (SRB) diversity and abundance on limited aeration condition was obviously inhibited. Limited aeration condition was benefit for the removal of benzene ring organics, such as benzene, toluene, ethylbenzene and xylenes (BTEX), improving the toxicity and treatability of the wastewater. Based on the experiment results, an anaerobic hydrolysis acidification tank (100,000 m(3)) has been transformed into limited aeration hydrolysis acidification tank and it runs well.

  17. Photosynthetic aeration in biological wastewater treatment using immobilized microalgae-bacteria symbiosis.

    PubMed

    Praveen, Prashant; Loh, Kai-Chee

    2015-12-01

    Chlorella vulgaris encapsulated in alginate beads were added into a bioreactor treating synthetic wastewater using Pseudomonas putida. A symbiotic CO2/O2 gas exchange was established between the two microorganisms for photosynthetic aeration of wastewater. During batch operation, glucose removal efficiency in the bioreactor improved from 50% in 12 h without aeration to 100% in 6 h, when the bioreactor was aerated photosynthetically. During continuous operation, the bioreactor was operated at a low hydraulic retention time of 3.3 h at feed concentrations of 250 and 500 mg/L glucose. The removal efficiency at 500 mg/L increased from 73% without aeration to 100% in the presence of immobilized microalgae. The initial microalgae concentration was critical to achieve adequate aeration, and the removal rate increased with increasing microalgae concentration. The highest removal rate of 142 mg/L-h glucose was achieved at an initial microalgae concentration of 190 mg/L. Quantification of microalgae growth in the alginate beads indicated an exponential growth during symbiosis, indicating that the bioreactor performance was limited by oxygen production rates. Under symbiotic conditions, the chlorophyll content of the immobilized microalgae increased by more than 30%. These results indicate that immobilized microalgae in symbiosis with heterotrophic bacteria are promising in wastewater aeration.

  18. Aeration effect on Spirulina platensis growth and γ-Linolenic acid production.

    PubMed

    Ronda, Srinivasa Reddy; Bokka, Chandra Sekhar; Ketineni, Chandrika; Rijal, Binod; Allu, Prasada Rao

    2012-01-01

    The influence of aeration on algal growth and gamma-linolenic acid (GLA) production in a bubble column photobioreactor was investigated. Studies were performed in a 20-L reactor at different aeration rates (0.2- 2.5 vvm). Static, continuous, and periodic operation of air resulted in 41.9%, 88.4%, and 108% air saturation of dissolved oxygen, for which the corresponding values of GLA were 2.3, 6.5, and 7.5 mg·g(-1) dry cell weight, respectively. An increase in the aeration rate from 0.2 to 2.5 vvm enhanced both the specific growth rate and GLA content under periodic sparging in the bicarbonate medium. With a 6-fold increase in the aeration rate, the GLA content of the alga increased by 69.64% (5.6-9.5 mg· g(-1) dry cell weight). In addition, the total fatty acid (TFA) content in dry biomass increased from 2.22% to 4.41%, whereas the algae maintained a constant GLA to TFA ratio within the aeration rate tested. The dependence of GLA production on the aeration rate was explained by interrelating the GLA production rate with the specific growth rate using the Luedeking and Piret mixed growth model.

  19. Laboratory study of nitrification, denitrification and anammox processes in membrane bioreactors considering periodic aeration.

    PubMed

    Abbassi, Rouzbeh; Yadav, Asheesh Kumar; Huang, Shan; Jaffé, Peter R

    2014-09-01

    The possibility of using membrane bioreactors (MBRs) in simultaneous nitrification-anammox-denitrification (SNAD) by considering periodic aeration cycles was investigated. Two separate reactors were operated to investigate the effect of different anammox biomass in the presence of nitrifying and denitrifying biomass on the final nitrogen removal efficiency. The results illustrated that the reactor with higher anammox biomass was more robust to oxygen cycling. Around 98% Total Nitrogen (TN) and 83% Total Organic Carbon (TOC) removal efficiencies were observed by applying one hour aeration over a four-hour cycle. Decreasing the aeration time to 30, 15, and 2 min during a four-hour cycle affected the final TN removal efficiencies. However, the effect of decreasing aeration on the TN removal efficiencies in the reactor with higher anammox biomass was much lower compared to the regular reactor. The nitrous oxide (N2O) emission was a function of aeration as well, and was lower in the reactor with higher anammox biomass. The results of q-PCR analysis confirmed the simultaneous co-existence of nitrifiers, anammox, and denitrifiers in both of the reactors. To simulate the TN removal in these reactors as a function of the aeration time, a new model, based on first order reaction kinetics for both denitrification and anammox was developed and yielded a good agreement with the experimental observations.

  20. Improving arachidonic acid fermentation by Mortierella alpina through multistage temperature and aeration rate control in bioreactor.

    PubMed

    Gao, Min-Jie; Wang, Cheng; Zheng, Zhi-Yong; Zhu, Li; Zhan, Xiao-Bei; Lin, Chi-Chung

    2016-05-18

    Effective production of arachidonic acid (ARA) using Mortierella alpina was conducted in a 30-L airlift bioreactor. Varying the aeration rate and temperature significantly influenced cell morphology, cell growth, and ARA production, while the optimal aeration rate and temperature for cell growth and product formation were quite different. As a result, a two-stage aeration rate control strategy was constructed based on monitoring of cell morphology and ARA production under various aeration rate control levels (0.6-1.8 vvm). Using this strategy, ARA yield reached 4.7 g/L, an increase of 38.2% compared with the control (constant aeration rate control at 1.0 vvm). Dynamic temperature-control strategy was implemented based on the fermentation performance at various temperatures (13-28°C), with ARA level in total cellular lipid increased by 37.1% comparing to a constant-temperature control (25°C). On that basis, the combinatorial fermentation strategy of two-stage aeration rate control and dynamic temperature control was applied and ARA production achieved the highest level of 5.8 g/L.

  1. [Oxygen transfer efficiency of four kinds substrates applied in artificial aeration vertical-flow wetland].

    PubMed

    Pan, Ji-Zheng; Li, Wen-Chao; Ke, Fan; Wang, Lei; Li, Xue-Juan

    2009-02-15

    In subsurface flow constructed wetlands, artificial aeration plays an important role in enhancing the ability of pollutant removal. Oxygenation capacity of four substrates, limestone, vesuvianite, 500 grade ceramisite and high-strength ceramisite, are tested under three kinds of gas volume [0.19, 0.38, 0.76 m3 x (m2 x h)(-1)] in artificial aeration vertical-flow wetland. When the gas volume is 0.19 m3 x (m2 x h)(-1), the results demonstrate that the oxygen utilization of 500 grade ceramisite and high-strength ceramisite are highest as 14.39% and 14.21%, and the oxygen utilization of limestone and vesuvianite are 11.68% and 13.11% respectively. With the increase of aeration intensity, oxygen transfer efficiency parameter KLa rises accordingly. However, the oxygen utilization of vesuvianite and two other kinds of ceramisite decreases with the increase of aeration intensity. The oxygen utilization of vesuvianite, 500 grad ceramisite and high-strength ceramisite are lower as 7.67%, 10.46% and 10.77% respectively when the aeration intensity is 0.76 m3 x (m2 x h)(-1). On the contrary, the oxygen utilization of limestone get its maximum value of 14.04% as the aeration intensity is 0.38 m3 x (m2 x h)(-1).

  2. An aeration control strategy for oxidation ditch processes based on online oxygen requirement estimation.

    PubMed

    Zhan, J X; Ikehata, M; Mayuzumi, M; Koizumi, E; Kawaguchi, Y; Hashimoto, T

    2013-01-01

    A feedforward-feedback aeration control strategy based on online oxygen requirements (OR) estimation is proposed for oxidation ditch (OD) processes, and it is further developed for intermittent aeration OD processes, which are the most popular type in Japan. For calculating OR, concentrations of influent biochemical oxygen demand (BOD) and total Kjeldahl nitrogen (TKN) are estimated online by the measurement of suspended solids (SS) and sometimes TKN is estimated by NH4-N. Mixed liquor suspended solids (MLSS) and temperature are used to estimate the required oxygen for endogenous respiration. A straightforward parameter named aeration coefficient, Ka, is introduced as the only parameter that can be tuned automatically by feedback control or manually by the operators. Simulation with an activated sludge model was performed in comparison to fixed-interval aeration and satisfying result of OR control strategy was obtained. The OR control strategy has been implemented at seven full-scale OD plants and improvements in nitrogen removal are obtained in all these plants. Among them, the results obtained in Yumoto wastewater treatment plant were presented, in which continuous aeration was applied previously. After implementing intermittent OR control, the total nitrogen concentration was reduced from more than 5 mg/L to under 2 mg/L, and the electricity consumption was reduced by 61.2% for aeration or 21.5% for the whole plant. PMID:23823542

  3. Evaluation of aeration energy saving in two modified activated sludge processes.

    PubMed

    Lee, Ingyu; Lim, Honglae; Jung, Byunghun; Colosimo, Mark F; Kim, Hyunook

    2015-12-01

    A variety of modified activated sludge processes are widely used in wastewater treatment plants (WWTPs) for removing organics and nutrients (N and P). Since energy consumption in aeration basin accounts for the major part of the overall energy usage in WWTPs, efforts have been made to find ways to reduce aeration energy. In this study, two modified activated sludge processes in a pilot scale designed for nutrient removal were evaluated for the extent of energy saving: (1) ABA(2) process - adjusting air on/off period (i.e., with a temporal change); and (2) MB-A(2)O process - changing volume ratio of aerobic tank to anoxic tank (i.e., with a spatial change). For the 1st process, the air on/off period was fixed at 60min/45min with aerobic fraction being 0.57, while for the 2nd process, the aerobic/anoxic volume ratio was reduced from 0.58 to 0.42. The results demonstrate that the effluent COD, TN, NH4(+) and TP concentrations are acceptable while reduced aeration time/volume certainly saves significant energy consumption. To the best of our knowledge, this is 1st attempt to reduce the aeration period or aeration volume to save the aeration energy in these two modified activated sludge processes. The implication of these observations is further discussed.

  4. Generating CO{sub 2}-credits through landfill in situ aeration

    SciTech Connect

    Ritzkowski, M.; Stegmann, R.

    2010-04-15

    Landfills are some of the major anthropogenic sources of methane emissions worldwide. The installation and operation of gas extraction systems for many landfills in Europe and the US, often including technical installations for energy recovery, significantly reduced these emissions during the last decades. Residual landfill gas, however, is still continuously produced after the energy recovery became economically unattractive, thus resulting in ongoing methane emissions for many years. By landfill in situ aeration these methane emissions can be widely avoided both, during the aeration process as well as in the subsequent aftercare period. Based on model calculations and online monitoring data the amount of avoided CO{sub 2-eq}. can be determined. For an in situ aerated landfill in northern Germany, acting as a case study, 83-95% (depending on the kind and quality of top cover) of the greenhouse gas emission potential could be reduced under strictly controlled conditions. Recently the United Nations Framework Convention on Climate Change (UNFCCC) has approved a new methodology on the 'Avoidance of landfill gas emissions by in situ aeration of landfills' (). Based on this methodology landfill aeration projects might be considered for generation of Certified Emission Reductions (CERs) in the course of CDM projects. This paper contributes towards an evaluation of the potential of landfill aeration for methane emissions reduction.

  5. Aeration effect on Spirulina platensis growth and γ-Linolenic acid production

    PubMed Central

    Ronda, Srinivasa Reddy; Bokka, Chandra Sekhar; Ketineni, Chandrika; Rijal, Binod; Allu, Prasada Rao

    2012-01-01

    The influence of aeration on algal growth and gamma-linolenic acid (GLA) production in a bubble column photobioreactor was investigated. Studies were performed in a 20-L reactor at different aeration rates (0.2– 2.5 vvm). Static, continuous, and periodic operation of air resulted in 41.9%, 88.4%, and 108% air saturation of dissolved oxygen, for which the corresponding values of GLA were 2.3, 6.5, and 7.5 mg·g-1 dry cell weight, respectively. An increase in the aeration rate from 0.2 to 2.5 vvm enhanced both the specific growth rate and GLA content under periodic sparging in the bicarbonate medium. With a 6-fold increase in the aeration rate, the GLA content of the alga increased by 69.64% (5.6–9.5 mg· g-1 dry cell weight). In addition, the total fatty acid (TFA) content in dry biomass increased from 2.22% to 4.41%, whereas the algae maintained a constant GLA to TFA ratio within the aeration rate tested. The dependence of GLA production on the aeration rate was explained by interrelating the GLA production rate with the specific growth rate using the Luedeking and Piret mixed growth model. PMID:24031799

  6. Nitrogen removal in intermittently aerated biofilm airlift reactor

    SciTech Connect

    Benthum, W.A.J. van; Mathijssen, J.P.M.; Sunde, J.; Loosdrecht, M.C.M. van; Heijnen, J.J.; Garrido, J.M.

    1998-03-01

    Nitrogen compounds like ammonium, nitrite, and nitrate can be found in domestic as well as industrial wastewaters. These compounds can cause many environmental problems in surface waters but can be removed by applying nitrification and denitrification processes. Denitrification was integrated in a nitrifying biofilm airlift suspension reactor by intermittent aeration. A total nitrogen-removal efficiency of 75% was reached at an aerobic ammonia load of 5 kg{sub N}{center_dot}m{sup {minus}3}{center_dot}d{sup {minus}1}. Acetate was added to the reactor during the anoxic periods. The system was operated at sufficiently long anoxic hydraulic retention times to allow suspended growth of denitrifying heterotrophs. However, the heterotrophic biomass did not grow in suspension but grew as protuberances and layers on the nitrifying biofilms. Nitrification and denitrification occurred via nitrite as an intermediate, possibly because denitrifiers outcompeted the nitrite oxidizers. Because of the establishing of the nitrite route, a low average COD/N ratio of 2.6 kg{sub COD}{center_dot}kg{sub N}{sup {minus}1} was obtained. When denitrifying operation with acetate addition was started, initially almost all nitrogen removed was emitted as nitrous oxide. Subsequently, the nitrous oxide emission strongly decreased to almost zero in a period of 30 days, while the nitrogen-removal efficiency was maintained.

  7. Removal of pharmaceuticals in aerated biofilters with manganese feeding.

    PubMed

    Zhang, Yongjun; Zhu, Hong; Szewzyk, Ulrich; Geissen, Sven Uwe

    2015-04-01

    A tertiary treatment step is required in current wastewater treatment plants to remove trace pollutants and thus to prevent their extensive occurrence in the aquatic environment. In this study, natural MnOx ore and natural zeolite were separately used to pack two lab-scale aerated biofilters, which were operated in approximately 1.5 years for the removal of frequently occurring pharmaceuticals, including carbamazepine (CBZ), diclofenac (DFC), and sulfamethoxazole (SMX), out of synthetic and real secondary effluents. Mn(2+) was added in the feeds to promote the growth of iron/manganese oxidizing bacteria which were recently found to be capable of degrading recalcitrant pollutants. An effective removal (80-90%) of DFC and SMX was observed in both biofilters after adaptation while a significant removal of CBZ was not found. Both biofilters also achieved an effective removal of spiked Mn(2+), but a limited removal of carbon and nitrogen contents. Additionally, MnOx biofilter removed 50% of UV254 from real secondary effluent, indicating a high potential on the removal of aromatic compounds.

  8. Redistribution of pulmonary blood flow impacts thermodilution-based extravascular lung water measurements in a model of acute lung injury

    PubMed Central

    Easley, R. Blaine; Mulreany, Daniel G.; Lancaster, Christopher T.; Custer, Jason W.; Fernandez-Bustamante, Ana; Colantuoni, Elizabeth; Simon, Brett A.

    2009-01-01

    Background Studies using transthoracic thermodilution have demonstrated increased extravascular lung water (EVLW) measurements attributed to progression of edema and flooding during sepsis and acute lung injury. We hypothesize that redistribution of pulmonary blood flow can cause increased apparent EVLW secondary to increased perfusion of thermally silent tissue, not increased lung edema. Methods Anesthetized, mechanically ventilated canines were instrumented with PiCCO® (Pulsion Medical, Munich, Germany) catheters and underwent lung injury by repetitive saline lavage. Hemodynamic and respiratory physiologic data were recorded. After stabilized lung injury, endotoxin was administered to inactivate hypoxic pulmonary vasoconstriction. Computerized tomographic imaging was performed to quantify in vivo lung volume, total tissue (fluid) and air content, and regional distribution of blood flow. Results Lavage injury caused an increase in airway pressures and decreased arterial oxygen content with minimal hemodynamic effects. EVLW and shunt fraction increased after injury and then markedly following endotoxin administration. Computerized tomographic measurements quantified an endotoxin-induced increase in pulmonary blood flow to poorly aerated regions with no change in total lung tissue volume. Conclusions The abrupt increase in EVLW and shunt fraction after endotoxin administration is consistent with inactivation of hypoxic pulmonary vasoconstriction and increased perfusion to already flooded lung regions that were previously thermally silent. Computerized tomographic studies further demonstrate in vivo alterations in regional blood flow (but not lung water) and account for these alterations in shunt fraction and EVLW. PMID:19809280

  9. Effect of hydraulic loading rate on pollutant removal efficiency in subsurface infiltration system under intermittent operation and micro-power aeration.

    PubMed

    Yang, Yongqiang; Zhan, Xuan; Wu, Shijun; Kang, Mingliang; Guo, Jianan; Chen, Fanrong

    2016-04-01

    The low hydraulic loading rate (HLR) greatly restricts the wide application of subsurface wastewater infiltration system (SWIS) in densely populated areas. To increase the HLR, an innovative SWIS was developed using cyclic operation mode. In each cycle, a wastewater feeding period is followed by a drying period, in which the aeration is conducted by a medium-pressure fan. Results indicated that the removal rate of TOC and NH4(+)-N were more than 85% at HLR of 0.5m(3)/m(2)d, whereas the TN removal rate was lower than 20%, indicating that the aeration was efficient and denitrification process was largely limited in the SWIS. When HLR decreased from 0.5 to 0.2m(3)/m(2)d, the pollutant removal efficiency enhanced slightly except for TN. Overall, the intermittent operation and micro-power aeration, combined with shunting the pollutant loading were really helpful for SWIS to achieve higher HLR, which offers a reference for the design of innovative SWIS.

  10. Effect of hydraulic loading rate on pollutant removal efficiency in subsurface infiltration system under intermittent operation and micro-power aeration.

    PubMed

    Yang, Yongqiang; Zhan, Xuan; Wu, Shijun; Kang, Mingliang; Guo, Jianan; Chen, Fanrong

    2016-04-01

    The low hydraulic loading rate (HLR) greatly restricts the wide application of subsurface wastewater infiltration system (SWIS) in densely populated areas. To increase the HLR, an innovative SWIS was developed using cyclic operation mode. In each cycle, a wastewater feeding period is followed by a drying period, in which the aeration is conducted by a medium-pressure fan. Results indicated that the removal rate of TOC and NH4(+)-N were more than 85% at HLR of 0.5m(3)/m(2)d, whereas the TN removal rate was lower than 20%, indicating that the aeration was efficient and denitrification process was largely limited in the SWIS. When HLR decreased from 0.5 to 0.2m(3)/m(2)d, the pollutant removal efficiency enhanced slightly except for TN. Overall, the intermittent operation and micro-power aeration, combined with shunting the pollutant loading were really helpful for SWIS to achieve higher HLR, which offers a reference for the design of innovative SWIS. PMID:26826957

  11. Long-term ambient air pollution and lung function impairment in Chinese children from a high air pollution range area: The Seven Northeastern Cities (SNEC) study

    NASA Astrophysics Data System (ADS)

    Zeng, Xiao-Wen; Vivian, Elaina; Mohammed, Kahee A.; Jakhar, Shailja; Vaughn, Michael; Huang, Jin; Zelicoff, Alan; Xaverius, Pamela; Bai, Zhipeng; Lin, Shao; Hao, Yuan-Tao; Paul, Gunther; Morawska, Lidia; Wang, Si-Quan; Qian, Zhengmin; Dong, Guang-Hui

    2016-08-01

    Epidemiological studies have reported inconsistent and inconclusive associations between long-term exposure to ambient air pollution and lung function in children from Europe and America, where air pollution levels were typically low. The aim of the present study is to examine the relationship between air pollutants and lung function in children selected from heavily industrialized and polluted cities in northeastern China. During 2012, 6740 boys and girls aged 7-14 years were recruited in 24 districts of seven northeastern cities. Portable electronic spirometers were used to measure lung function. Four-year average concentrations of particulate matter with an aerodynamic diameter ≤10 μm (PM10), sulfur dioxide (SO2), nitrogen dioxide (NO2), and ozone (O3) were measured at monitoring stations in the 24 districts. Two-staged regression models were used in the data analysis, controlling for covariates. Overall, for all subjects, the increased odds of lung function impairment associated with exposure to air pollutants, ranged from 5% (adjusted odds ratio [aOR] = 1.05; 95% confidence interval [CI] = 1.01, 1.10) for FVC < 85% predicted per 46.3 μg/m3 for O3 to 81% (aOR = 1.81; 95%CI = 1.44, 2.28) for FEV1 < 85% predicted per 30.6 μg/m3 for PM10. The linear regression models consistently showed a negative relationship between all air pollutants and lung function measures across subjects. There were significant interaction terms indicating gender differences for lung function impairment and pulmonary function from exposure to some pollutants (P < 0.10). In conclusion, long term exposure to high concentrations of ambient air pollution is associated with decreased pulmonary function and lung function impairment, and females appear to be more susceptible than males.

  12. Re-engineering the design criteria for sidestream elevated pool aeration

    SciTech Connect

    Farnan, J.C.

    1998-07-01

    The Metropolitan Water Reclamation District of Greater Chicago (District) has constructed five sidestream elevated pool aeration (SEPA) stations on the Calumet Waterway System (CWS) for replenishing dissolved oxygen (DO) in the waterway. A major component of the CWS is the Cal Sag Channel which has a width of 225 feet (68.6 meters) and a depth of 9 feet (2.7 meters). The CWS is a very slow moving waterway having a one foot drop in 37,000 feet (11.280 meters) which does not have the ability to maintain the Illinois Pollution Control Board's requirement of not less than 3 mg/l at any time. the need to raise the DO to the 3 mg/level led to the innovative design of SEPA stations which are also known as urban waterfall stations. The name urban waterfall is a term coined to describe a man made waterfall located in metropolitan areas. These urban waterfalls impart DO to the water similar to natural waterfalls. These stations were selected as the cost effective alternative to advanced wastewater treatment. Built at a cost of $40 million, the system saved taxpayers at least $260 million. This creative project brought the District its third ASCE Outstanding Civil Engineering Achievement Award in 1994.

  13. [Lung ultrasound in the newborn].

    PubMed

    Yousef, N

    2016-03-01

    Lung ultrasound (LU) is becoming a bedside point-of-care technique in critical care and emergency medicine as it is performed and immediately interpreted by the clinician. LU is quick, easy, relatively inexpensive, and provides accurate diagnostic information when compared with conventional lung imaging methods, such as CT scans and chest radiographs, with the additional advantage of being non-irradiating, adapted to bedside use, and easily repeatable with no side effects for the patient. LU is easy to learn, does not require sophisticated ultrasound machines or settings, and shows low intra- and interobserver variability when a standardized approach is used. A comprehensive and standardized ultrasound semiology has been described and validated in both adults and children. In summary, LU allows for quick easy recognition of a normally aerated lung in contrast to an interstitial or alveolar pattern. Recognition of these patterns may be even easier in neonates due to their small size and the absence of obesity and heavy musculature. Specific LU findings have been described for some types of neonatal lung injury, such as neonatal respiratory distress syndrome, transient tachypnea of the neonate, meconium aspiration syndrome, and neonatal pneumonia. In the newborn, LU has proved its usefulness in predicting the need for hospital admission and/or intubation based on simple LU patterns. A recently proposed LU score, adapted for the neonate, correlates well with oxygenation status, independently of gestational age and underlying respiratory condition. The score reliably predicts the need for surfactant treatment in preterm babies less than 34 weeks gestation treated with nasal CPAP from birth. LU is a promising tool with numerous potential applications that warrant future studies. However, like every technique, LU has its limitations and should not completely replace standard radiography. LU can nevertheless largely reduce exposure to ionizing radiation by limiting the

  14. Reducing aeration energy consumption in a large-scale membrane bioreactor: Process simulation and engineering application.

    PubMed

    Sun, Jianyu; Liang, Peng; Yan, Xiaoxu; Zuo, Kuichang; Xiao, Kang; Xia, Junlin; Qiu, Yong; Wu, Qing; Wu, Shijia; Huang, Xia; Qi, Meng; Wen, Xianghua

    2016-04-15

    Reducing the energy consumption of membrane bioreactors (MBRs) is highly important for their wider application in wastewater treatment engineering. Of particular significance is reducing aeration in aerobic tanks to reduce the overall energy consumption. This study proposed an in situ ammonia-N-based feedback control strategy for aeration in aerobic tanks; this was tested via model simulation and through a large-scale (50,000 m(3)/d) engineering application. A full-scale MBR model was developed based on the activated sludge model (ASM) and was calibrated to the actual MBR. The aeration control strategy took the form of a two-step cascaded proportion-integration (PI) feedback algorithm. Algorithmic parameters were optimized via model simulation. The strategy achieved real-time adjustment of aeration amounts based on feedback from effluent quality (i.e., ammonia-N). The effectiveness of the strategy was evaluated through both the model platform and the full-scale engineering application. In the former, the aeration flow rate was reduced by 15-20%. In the engineering application, the aeration flow rate was reduced by 20%, and overall specific energy consumption correspondingly reduced by 4% to 0.45 kWh/m(3)-effluent, using the present practice of regulating the angle of guide vanes of fixed-frequency blowers. Potential energy savings are expected to be higher for MBRs with variable-frequency blowers. This study indicated that the ammonia-N-based aeration control strategy holds promise for application in full-scale MBRs.

  15. High-sulfate, high-chemical oxygen demand wastewater treatment using aerated methanogenic fluidized beds

    SciTech Connect

    Zitomer, D.H.; Shrout, J.D.

    2000-02-01

    Many industrial wastewaters have both high organic pollution and sulfate (SO{sub 4}{sup {minus}2}) concentrations. Although biological conversion of organics to methane may be an economical chemical oxygen demand (COD) removal option, significant inhibition of methane production results from reduction of SO{sub 4}{sup {minus}2} to hydrogen sulfide (H{sub 2}S), which is inhibitory to methanogenic microorganisms. Therefore, sulfate-containing wastewater is often not amenable to conventional anaerobic treatment. Recently, limited aeration of recycle flow to hybrid and baffled reactors has been used to treat this wastewater and has been shown to reduce aqueous H{sub 2}S concentrations by causing production of uninhibitory sulfur (S{degree}) and thiosulfate (S{sub 2}O{sub 3}{sup {minus}2}) as well as gas stripping volatile H{sub 2}S. In this study, directly aerated methanogenic fluidized bed reactors (FBRs) achieved increased methane production compared to strictly anaerobic FBRs treating high-sulfate wastewater. Oxygen transfer satisfying up to 28% of the COD load resulted in maximum specific oxygen utilization rates of 0.20 mg oxygen/g volatile solids{center{underscore}dot}min, with significant, concomitant methane production. Under typically inhibitory SO{sub 4}{sup {minus}2} loading, higher aeration caused increased effluent SO{sub 4}{sup {minus}2}, increased H{sub 2}S mass in the offgas, and lower reactor H{sub 2}S concentration. As a result, COD removal increased from 25% for a strictly anaerobic FBR to 87% for an aerated FBR. In addition, aerated systems required significantly less alkalinity supplementation to maintain a pH value of 7, ostensibly because of stripping of acidic carbon dioxide. The potential pH increase associated with aeration also shifts sulfide speciation to less toxic disulfide. Direct, limited aeration of methanogenic FBRs is described as a method for increased COD removal when treating high-COD, high-sulfate wastewater.

  16. Arsenic sorption in phosphate-amended soils during flooding and subsequent aeration

    SciTech Connect

    Reynolds, J.G.; Naylor, D.V.; Fendorf, S.E.

    1999-10-01

    Phosphate enhances the mobility of As in well-aerated soils by competing for adsorption sites. Phosphate and As may also coexist in large concentrations in hydric soils, and the influence of P on As in anaerobic systems is largely unknown. To determine the effects of P on As dynamics during a soil flooding and aeration cycle, samples of two soils were amended with Na{sub 2}HAsO{sub 4} and Na{sub 2}HPO, and incubated under a N{sub 2} atmosphere for 41 d, and then reaerated for 7 d. Subsamples were collected intermittently and dissolved As, Fe, Mn, Ca, S, P, and H{sub 3}AsO{sub 3} concentrations were determined. Arsenic speciation in the soil solids was determined after 14 and 41 d of flooding and then after 13 h of aeration by X-ray absorption near edge structure (XANES) spectroscopy. Arsenic sorption was small under anaerobic conditions, and H{sub 2}PO{sub 4}{sup {minus}} additions enhanced As(V) reduction rate in both soils and slightly suppressed As sorption in one soil. Arsenopyrite (FeAsS) was identified in the soil solids. Rapid and simultaneous As sorption and Fe precipitation occurred during the first 0.25 d of aeration, suggesting that As was retained on freshly precipitated Fe (hydr)oxides. Manganese precipitation and concomitant As sorption occurred after 1d of aeration. Arsenopyrite was largely destroyed upon aeration but As(III) persisted. Thus, As is partitioned into the solid phase under both aerobic and anaerobic conditions, although more appreciably under the aerobic conditions of this study, and P has little influence on dissolved As during soil flooding-aeration cycles.

  17. Evaluation of six aerator modules built on venturi air injectors using clean water test.

    PubMed

    Dong, C; Zhu, J; Miller, C F

    2009-01-01

    Six aerator modules constructed using venturi air injectors connected in either series or parallel were evaluated and compared for their oxygen transfer coefficients (OTC), standard oxygen transfer rate (SOTR), and standard oxygenation efficiency (SOE) determined by clean water tests. Modules in series (module a, b, c) included one, two, and three venturi injectors, respectively. The aerator module with two (module d) and three (module e, f) venturi injectors in parallel were used, while module f had less friction and more even flow rate in each line compared with module e. The results showed that the OTC, SOTR, and SOE for the six different module configurations (module a, b, c, d, e, f) were 4.54, 3.79, 3.58, 8.37, 5.93 and 11.87 h(-1); 0.10, 0.09, 0.09, 0.18, 0.15, and 0.31 kgO(2)/h; and 0.07, 0.06, 0.06, 0.12, 0.10, and 0.21 kgO(2)/kWh, respectively. The observations indicate that a 3-fold increase in SOTR and 3.5-fold increase in SOE can be obtained by simply changing the way that venturi air injectors are connected, which suggests that it is possible to improve the aeration efficiency of a venturi type aeration system by innovative aerator module designs. In view of the situation that the venturi aeration systems currently used for swine manure lagoons need significant improvement in their performance in order to match the cost-effective requirement, more research in aerator module development is needed so that effective control of odor from liquid swine manure lagoons can be achieved at an affordable cost. The technology such developed can also be applied to other livestock species. PMID:19717924

  18. Ambient iron-mediated aeration (IMA) for water reuse.

    PubMed

    Deng, Yang; Englehardt, James D; Abdul-Aziz, Samer; Bataille, Tristan; Cueto, Josenrique; De Leon, Omar; Wright, Mary E; Gardinali, Piero; Narayanan, Aarthi; Polar, Jose; Tomoyuki, Shibata

    2013-02-01

    Global water shortages caused by rapidly expanding population, escalating water consumption, and dwindling water reserves have rendered water reuse a strategically significant approach to meet current and future water demand. This study is the first to our knowledge to evaluate the technical feasibility of iron-mediated aeration (IMA), an innovative, potentially economical, holistic, oxidizing co-precipitation process operating at room temperature, atmospheric pressure, and neutral pH, for water reuse. In the IMA process, dissolved oxygen (O₂) was continuously activated by zero-valent iron (Fe⁰) to produce reactive oxygen species (ROS) at ambient pH, temperature, and pressure. Concurrently, iron sludge was generated as a result of iron corrosion. Bench-scale tests were conducted to study the performance of IMA for treatment of secondary effluent, natural surface water, and simulated contaminated water. The following removal efficiencies were achieved: 82.2% glyoxylic acid, ~100% formaldehyde as an oxidation product of glyoxylic acid, 94% of Ca²⁺ and associated alkalinity, 44% of chemical oxygen demand (COD), 26% of electrical conductivity (EC), 98% of di-n-butyl phthalate (DBP), 80% of 17β-estradiol (E2), 45% of total nitrogen (TN), 96% of total phosphorus (TP), 99.8% of total Cr, >90% of total Ni, 99% of color, 3.2 log removal of total coliform, and 2.4 log removal of E. Coli. Removal was attributed principally to chemical oxidation, precipitation, co-precipitation, coagulation, adsorption, and air stripping concurrently occurring during the IMA treatment. Results suggest that IMA is a promising treatment technology for water reuse.

  19. Lung Parenchymal Mechanics

    PubMed Central

    Suki, Béla; Stamenovic, Dimitrije; Hubmayr, Rolf

    2014-01-01

    The lung parenchyma comprises a large number of thin-walled alveoli, forming an enormous surface area, which serves to maintain proper gas exchange. The alveoli are held open by the transpulmonary pressure, or prestress, which is balanced by tissues forces and alveolar surface film forces. Gas exchange efficiency is thus inextricably linked to three fundamental features of the lung: parenchymal architecture, prestress, and the mechanical properties of the parenchyma. The prestress is a key determinant of lung deformability that influences many phenomena including local ventilation, regional blood flow, tissue stiffness, smooth muscle contractility, and alveolar stability. The main pathway for stress transmission is through the extracellular matrix. Thus, the mechanical properties of the matrix play a key role both in lung function and biology. These mechanical properties in turn are determined by the constituents of the tissue, including elastin, collagen, and proteoglycans. In addition, the macroscopic mechanical properties are also influenced by the surface tension and, to some extent, the contractile state of the adherent cells. This article focuses on the biomechanical properties of the main constituents of the parenchyma in the presence of prestress and how these properties define normal function or change in disease. An integrated view of lung mechanics is presented and the utility of parenchymal mechanics at the bedside as well as its possible future role in lung physiology and medicine are discussed. PMID:23733644

  20. Effect of artificial aeration on the performance of vertical-flow constructed wetland treating heavily polluted river water.

    PubMed

    Dong, Huiyu; Qiang, Zhimin; Li, Tinggang; Jin, Hui; Chen, Weidong

    2012-01-01

    Three lab-scale vertical-flow constructed wetlands (VFCWs), including the non-aerated (NA), intermittently aerated (IA) and continuously aerated (CA) ones, were operated at different hydraulic loading rates (HLRs) to evaluate the effect of artificial aeration on the treatment efficiency of heavily polluted river water. Results indicated that artificial aeration increased the dissolved oxygen (DO) concentrations in IA and CA, which significantly favored the removal of organic matter and NH(4+)-N. The DO grads caused by intermittent aeration formed aerobic and anoxic regions in IA and thus promoted the removal of total nitrogen (TN). Although the removal efficiencies of COD(Cr), NH(4+)-N and TN in the three VFCWs all decreased with an increase in HLR, artificial aeration enhanced the reactor resistance to the fluctuation of pollutant loadings. The maximal removal efficiencies of COD(Cr), NH(4+)-N and total phosphorus (TP) (i.e., 81%, 87% and 37%, respectively) were observed in CA at 19 cm/day HLR, while the maximal TN removal (i.e., 57%) was achieved in IA. Although the improvement of artificial aeration on TP removal was limited, this study has demonstrated the feasibility of applying artificial aeration to VFCWs treating polluted river water, particularly at a high HLR.

  1. Lung transplantation

    PubMed Central

    Afonso, José Eduardo; Werebe, Eduardo de Campos; Carraro, Rafael Medeiros; Teixeira, Ricardo Henrique de Oliveira Braga; Fernandes, Lucas Matos; Abdalla, Luis Gustavo; Samano, Marcos Naoyuki; Pêgo-Fernandes, Paulo Manuel

    2015-01-01

    ABSTRACT Lung transplantation is a globally accepted treatment for some advanced lung diseases, giving the recipients longer survival and better quality of life. Since the first transplant successfully performed in 1983, more than 40 thousand transplants have been performed worldwide. Of these, about seven hundred were in Brazil. However, survival of the transplant is less than desired, with a high mortality rate related to primary graft dysfunction, infection, and chronic graft dysfunction, particularly in the form of bronchiolitis obliterans syndrome. New technologies have been developed to improve the various stages of lung transplant. To increase the supply of lungs, ex vivo lung reconditioning has been used in some countries, including Brazil. For advanced life support in the perioperative period, extracorporeal membrane oxygenation and hemodynamic support equipment have been used as a bridge to transplant in critically ill patients on the waiting list, and to keep patients alive until resolution of the primary dysfunction after graft transplant. There are patients requiring lung transplant in Brazil who do not even come to the point of being referred to a transplant center because there are only seven such centers active in the country. It is urgent to create new centers capable of performing lung transplantation to provide patients with some advanced forms of lung disease a chance to live longer and with better quality of life. PMID:26154550

  2. Lung Diseases

    MedlinePlus

    When you breathe, your lungs take in oxygen from the air and deliver it to the bloodstream. The cells in your body need oxygen to ... you breathe nearly 25,000 times. People with lung disease have difficulty breathing. Millions of people in ...

  3. Lung Cancer

    MedlinePlus

    Lung cancer is one of the most common cancers in the world. It is a leading cause of cancer death in men and women in the United States. Cigarette smoking causes most lung cancers. The more cigarettes you smoke per day and ...

  4. Lung diffusion testing

    MedlinePlus

    Lung diffusion testing measures how well the lungs exchange gases. This is an important part of lung testing , because ... gases do not move normally across the lung tissues into the blood vessels of the lung. This ...

  5. Collapsed lung (pneumothorax)

    MedlinePlus

    Air around the lung; Air outside the lung; Pneumothorax dropped lung; Spontaneous pneumothorax ... Collapsed lung can be caused by an injury to the lung. Injuries can include a gunshot or knife wound ...

  6. Lung disease - resources

    MedlinePlus

    Resources - lung disease ... The following organizations are good resources for information on lung disease : American Lung Association -- www.lung.org National Heart, Lung, and Blood Institute -- www.nhlbi.nih.gov ...

  7. Lung cancer and air pollution.

    PubMed

    Aoki, K; Shimizu, H

    1977-12-01

    The relationship between incidence of lung cancer and the volume of traffic as indicated by auto exhaust concentration was examined; the results, though suggestive, did not yield consistent evidence of the association between them. Traffic jams in Nagoya began 15 years ago, a period that may not be long enough to provide definitive data on the incidence of lung cancer. The high standardized mortality ratio (SMR) of lung cancer was observed in cities with a population of less than 1 million and guns (rural areas) along the coast, although those in the metropolitan areas with populations of more than 1 million were average. The SMR did not correlate with various socioeconomic conditions and industrial air pollution. Meteorologic or geologic conditions and ocean currents were not associated with SMR of lung cancer by city and gun. The population of a gun or of some cities was not large enough to be statistically significant, and the mortality rate of lung cancer was not always stable.

  8. Rapid Start-up and Loading of an Attached Growth, Simultaneous Nitrification/Denitrification Membrane Aerated Bioreactor

    NASA Technical Reports Server (NTRS)

    Meyer, Caitlin E.; Pensinger, Stuart; Pickering, Karen D.; Barta, Daniel; Shull, Sarah A.; Vega, Letticia M.; Christenson, Dylan; Jackson, W. Andrew

    2015-01-01

    Membrane aerated bioreactors (MABR) are attached-growth biological systems used for simultaneous nitrification and denitrification to reclaim water from waste. This design is an innovative approach to common terrestrial wastewater treatments for nitrogen and carbon removal and implementing a biologically-based water treatment system for long-duration human exploration is an attractive, low energy alternative to physiochemical processes. Two obstacles to implementing such a system are (1) the "start-up" duration from inoculation to steady-state operations and (2) the amount of surface area needed for the biological activity to occur. The Advanced Water Recovery Systems (AWRS) team at JSC explored these two issues through two tests; a rapid inoculation study and a wastewater loading study. Results from these tests demonstrate that the duration from inoculation to steady state can be reduced to under two weeks, and that despite low ammonium removal rates, the MABRs are oversized.

  9. Investigation of Hydrogen Sulfide Exposure and Lung Function, Asthma and Chronic Obstructive Pulmonary Disease in a Geothermal Area of New Zealand

    PubMed Central

    Bates, Michael N.; Crane, Julian; Balmes, John R.; Garrett, Nick

    2015-01-01

    Background Results have been conflicting whether long-term ambient hydrogen sulfide (H2S) affects lung function or is a risk factor for asthma or chronic obstructive pulmonary disease (COPD). Rotorua city, New Zealand, has the world’s largest population exposed to ambient H2S—from geothermal sources. Objectives We investigated associations of H2S with lung function, COPD and asthma in this population. Methods 1,204 of 1,639 study participants, aged 18–65 years during 2008–2010, provided satisfactory spirometry results. Residences, workplaces and schools over the last 30 years were geocoded. Exposures were estimated from data collected by summer and winter H2S monitoring networks across Rotorua. Four metrics for H2S exposure, representing both current and long-term (last 30 years) exposure, and also time-weighted average and peak exposures, were calculated. Departures from expected values for pre-bronchodilator lung function, calculated from prediction equations, were outcomes for linear regression models using quartiles of the H2S exposure metrics. Separate models examined participants with and without evidence of asthma or COPD, and never- and ever-smokers. Logistic regression was used to investigate associations of COPD (a post-bronchodilator FEV1/FVC < 70% of expected) and asthma (doctor-diagnosed or by FEV1 response to bronchodilator) with H2S exposure quartiles. Results None of the exposure metrics produced evidence of lung function decrement. The logistic regression analysis showed no evidence that long-term H2S exposure at Rotorua levels was associated with either increased COPD or asthma risk. Some results suggested that recent ambient H2S exposures were beneficially associated with lung function parameters. Conclusions The study found no evidence of reductions in lung function, or increased risk of COPD or asthma, from recent or long-term H2S exposure at the relatively high ambient concentrations found in Rotorua. Suggestions of improved lung

  10. Monitoring transitory profiles of leachate humic substances in landfill aeration reactors in mesophilic and thermophilic conditions.

    PubMed

    Tong, Huanhuan; Yin, Ke; Ge, Liya; Giannis, Apostolos; Chuan, Valerie W L; Wang, Jing-Yuan

    2015-04-28

    The presence of humic substances (HS) in landfill leachate is of great interest because of their structural stability and potential toxicity. This study examined the effects of temperature and waste age on the transformation of HS during in situ aeration of bioreactor landfills. By establishing aerobic conditions, dissolved organic carbon (DOC) rapidly accumulated in the bioreactor leachate. Fractional analysis showed that the elevated concentration of humic acids (HAs) was primarily responsible for the increment of leachate strength. Further structural characterization indicated that the molecular weight (MW) and aromacity of HS were enhanced by aeration in conjunction with thermophilic temperature. Interestingly, elevation of HAs concentration was not observed in the aeration reactor with a prolonged waste age, as the mobility of HAs was lowered by the high MW derived from extended waste age. Based on these results, aeration may be more favorable in aged landfills, since dissolution of HAs could be minimized by the evolution to larger MW compared to young landfills. Moreover, increased operation temperature during aeration likely offers benefits for the rapid maturation of HS.

  11. Municipal waste stabilization in a reactor with an integrated active and passive aeration system.

    PubMed

    Kasinski, Slawomir; Slota, Monika; Markowski, Michal; Kaminska, Anna

    2016-04-01

    To test whether an integrated passive and active aeration system could be an effective solution for aerobic decomposition of municipal waste in technical conditions, a full-scale composting reactor was designed. The waste was actively aerated for 5d, passively aerated for 35 d, and then actively aerated for 5d, and the entire composting process was monitored. During the 45-day observation period, changes in the fractional, morphological and physico-chemical characteristics of the waste at the top of the reactor differed from those in the center of the reactor. The fractional and morphological analysis made during the entire process of stabilization, showed the total reduction of organic matter measured of 82 wt% and 86 wt% at the respective depths. The reduction of organic matter calculated using the results of Lost of Ignition (LOI) and Total Organic Carbon (TOC) showed, respectively, 40.51-46.62% organic matter loss at the top and 45.33-53.39% in the center of the reactor. At the end of the process, moisture content, LOI and TOC at the top were 3.29%, 6.10% and 4.13% higher, respectively, than in the center. The results showed that application of passive aeration in larger scale simultaneously allows the thermophilic levels to be maintained during municipal solid waste composting process while not inhibiting microbial activity in the reactor.

  12. Landfill aeration within the scope of post-closure care and its completion.

    PubMed

    Ritzkowski, Marco; Stegmann, Rainer

    2013-10-01

    The time frame required for post-closure care of Municipal Solid Waste (MSW) landfills is often assessed over several decades or centuries. One possibility to significantly shorten this period and, at the same time, improve the emission behavior exists with in situ aeration. Positive effects in connection with this method for biological stabilization have been investigated and published elsewhere. However, until today neither generally accepted monitoring guidelines nor completion criteria have been defined. With the paper on hand the authors propose a methodology for the assessment of both, total and remaining stabilization periods for aerated landfills. The central component of this methodology is a carbon balance. The latter is based on a detailed waste characterization in combination with online monitoring of the emissions (gas and leachate). The methodology is exemplarily demonstrated by means of data derived from a full scale project in Northern Germany. Here it could be shown that the predicted aeration period of approximately 6.4years was sufficient to bio-stabilize the landfill. Furthermore, proposals for the completion of landfill aeration are presented. In this connection, carbon balance is of particular importance since the amount of biodegradable organic carbon mainly determines the emission potential. Additional parameters, aiming at a validation of the state of biological stabilization achieved during aeration are proposed and described.

  13. [Effect of Intermittent Aeration on Nitrogen Removal Efficiency in Vertical Subsurface Flow Constructed Wetland].

    PubMed

    Wang, Jian; Li, Huai-zheng; Zhen, Bao-chong; Liu, Zhen-dong

    2016-03-15

    One-stage vertical subsurface flow constructed wetlands (CWs) were used to treat effluent from grit chamber in municipal wastewater treatment plant. The CW was divided into aerobic zone and anoxic zone by means of raising the effluent level and installing a perforated pipe. Two parameters (the ratio of aeration time and nonaeration time, aeration cycle) were optimized in the experiment to enhance nitrogen removal efficiency. The results suggested that the removal rates of COD and NH₄⁺-N increased while TN showed a trend of first increasing and then decreasing with the increasing ratio. When the ratio was 3:1, the C/N value in the anoxic zone was 4. 8. And the TN effluent concentration was 15.8 mg · L⁻¹ with the highest removal rate (62.1%), which was increased by 12.7% compared with continuous aeration. As the extension of the aeration cycle, the DO effluent concentration as well as the removal rates of COD and NH: -N declined gradually. The TN removal rate reached the maximum (65.5%) when the aeration cycle was 6h. However, the TN removal rate dropped rapidly when the cycle exceeded the hydraulic retention time in the anoxic zone.

  14. Nitrogen transformations and retention in planted and artificially aerated constructed wetlands.

    PubMed

    Maltais-Landry, Gabriel; Maranger, Roxane; Brisson, Jacques; Chazarenc, Florent

    2009-02-01

    Nitrogen (N) processing in constructed wetlands (CWs) is often variable, and the contribution to N loss and retention by various pathways (nitrification/denitrification, plant uptake and sediment storage) remains unclear. We studied the seasonal variation of the effects of artificial aeration and three different macrophyte species (Phragmites australis, Typha angustifolia and Phalaris arundinacea) on N processing (removal rates, transformations and export) using experimental CW mesocosms. Removal of total nitrogen (TN) was higher in summer and in planted and aerated units, with the highest mean removal in units planted with T. angustifolia. Export of ammonium (NH(4)(+)), a proxy for nitrification limitation, was higher in winter, and in unplanted and non-aerated units. Planted and aerated units had the highest export of oxidized nitrogen (NO(y)), a proxy for reduced denitrification. Redox potential, evapotranspiration (ETP) rates and hydraulic retention times (HRT) were all predictors of TN, NH(4)(+) and NO(y) export, and significantly affected by plants. Denitrification was the main N sink in most treatments accounting for 47-62% of TN removal, while sediment storage was dominant in unplanted non-aerated units and units planted with P. arundinacea. Plant uptake accounted for less than 20% of the removal. Uncertainties about the long-term fate of the N stored in sediments suggest that the fraction attributed to denitrification losses could be underestimated in this study.

  15. Limited aeration of methanogenic systems for treatment of sulfate-containing wastewater

    SciTech Connect

    Zitomer, D.H.; Shrout, J.D.

    1998-07-01

    Wastewaters with high sulfate concentrations are often not readily amenable to methanogenic treatment due to production of potentially inhibitory hydrogen sulfide. Some reports indicate that treatment has been enhanced by air sparging of recycle flows to air-strip hydrogen sulfide and create a selective environment for reduction of sulfate to elemental sulfur, rather than sulfides and thiosulfate. In this report, direct aeration of methanogenic expanded beds was employed for treatment of high-sulfate wastewater and compared to a strictly anaerobic control. An influent wastewater COD:SO{sup {minus}2}{sub 4} ratio as low as 4,4:1 did not discernibly inhibit methane production in the anaerobic control. At a relatively high OLR of 30g COD/L{sub A}-d and a relatively short HRT of 4.2 hours, the COD removal of the control was 97%. Methanogenesis was also sustained in the aerated reactors which had oxygen transfer rates of between 2 to 5% of the OLR. These aerated reactors converted approximately 70% of the COD to methane. Future research will involve higher sulfate loadings and aeration rates to determine possible benefits of direct aeration of methanogenic expanded beds.

  16. Raising and controlling study of dissolved oxygen concentration in closed-type aeration tank.

    PubMed

    Chen, C K; Lo, S L

    2005-07-01

    This study investigated the promotion and control of dissolved oxygen (DO) concentration of the closed-type aeration tank via practical experiments in the wastewater treatment system of a 5-star hotel in Taipei. As with limited and treasured space in Taiwan, before the completion of the sewer system construction in cities, to utilize the mat foundation under large buildings as the space of sewage treatment plant still has been one of the alternatives of those sewage treatments. However, aeration tanks constructed in the mat foundation of buildings have smaller effective water depth, which will cause a lower total transfer amount of DO. Controlling the total exhaust gas flow rate can increase the pressure on such closed-type aeration tanks. The DO concentration thus may increase according to Henry's Law. Furthermore, it may enable operators to adjust the DO concentration of the aeration tank more precisely and thus sustain optimal operating conditions in these treatment facilities. Practical experiments indicated that the DO concentration of aeration tank maintains an average of 3.8 mg l(-1), obtaining the optimum operating conditions. The efficiency of the biological treatment facilities in the mat foundation could be markedly improved. PMID:16080335

  17. Aerated Shewanella oneidensis in continuously fed bioelectrochemical systems for power and hydrogen production.

    PubMed

    Rosenbaum, Miriam; Cotta, Michael A; Angenent, Largus T

    2010-04-01

    We studied the effects of aeration of Shewanella oneidensis on potentiostatic current production, hydrogen production in a microbial electrolysis cell, and electric power generation in a microbial fuel cell (MFC). The potentiostatic performance of aerated S. oneidensis was considerably enhanced to a maximum current density of 0.45 A/m(2) or 80.3 A/m(3) (mean: 0.34 A/m(2), 57.2 A/m(3)) compared to anaerobically grown cultures. Biocatalyzed hydrogen production rates with aerated S. oneidensis were studied within the applied potential range of 0.3-0.9 V and were highest at 0.9 V with 0.3 m(3) H(2)/m(3) day, which has been reported for mixed cultures, but is approximately 10 times higher than reported for an anaerobic culture of S. oneidensis. Aerated MFC experiments produced a maximum power density of 3.56 W/m(3) at a 200-Omega external resistor. The main reasons for enhanced electrochemical performance are higher levels of active biomass and more efficient substrate utilization under aerobic conditions. Coulombic efficiencies, however, were greatly reduced due to losses of reducing equivalents to aerobic respiration in the anode chamber. The next challenge will be to optimize the aeration rate of the bacterial culture to balance between maximization of bacterial activation and minimization of aerobic respiration in the culture.

  18. Maximization of beta-galactosidase production: a simultaneous investigation of agitation and aeration effects.

    PubMed

    Alves, Fernanda Germano; Filho, Francisco Maugeri; de Medeiros Burkert, Janaína Fernandes; Kalil, Susana Juliano

    2010-03-01

    In this work, the agitation and aeration effects in the maximization of the beta-galactosidase production from Kluyveromyces marxianus CCT 7082 were investigated simultaneously, in relation to the volumetric enzyme activity and the productivity, as well as the analysis of the lactose consumption and production of glucose, and galactose of this process. Agitation and aeration effects were studied in a 2 L batch stirred reactor. A central composite design (2(2) trials plus three central points) was carried out. Agitation speed varied from 200 to 500 rpm and aeration rate from 0.5 to 1.5 vvm. It has been shown in this study that the volumetric enzyme production was strongly influenced by mixing conditions, while aeration was shown to be less significant. Linear models for activity and productivity due to agitation and aeration were obtained. The favorable condition was 500 rpm and 1.5 vvm, which lead to the best production of 17 U mL(-1) for enzymatic activity, 1.2 U mL(-1) h(-1) for productivity in 14 h of process, a cellular concentration of 11 mg mL(-1), and a 167.2 h(-1) volumetric oxygen transfer coefficient. PMID:19517069

  19. Performance of intermittent aeration reactor on NH4-N removal from groundwater resources.

    PubMed

    Khanitchaidecha, W; Nakamura, T; Sumino, T; Kazama, F

    2010-01-01

    To study the effect of intermittent aeration period on ammonium-nitrogen (NH4-N) removal from groundwater resources, synthetic groundwater was prepared and three reactors were operated under different conditions--"reactor A" under continuous aeration, "reactor B" under 6 h intermittent aeration, and "reactor C" under 2 h intermittent aeration. To facilitate denitrification simultaneously with nitrification, "acetate" was added as an external carbon source with step-wise increase from 0.5 to 1.5 C/N ratio, where C stands for total carbon content in the system, and N for NH4-N concentration in the synthetic groundwater. Results show that complete NH4-N removal was obtained in "reactor B" and "reactor C" at 1.3 and 1.5 C/N ratio respectively; and partial NH4-N removal in "reactor A". These results suggest that intermittent aeration at longer interval could enhance the reactor performance on NH4-N removal in terms of efficiency and low external carbon requirement. Because of consumption of internal carbon by the process, less amount of external carbon is required. Further increase in carbon in a form of acetate (1.5 to 2.5 C/N ratios) increases removal rate (represented by reaction rate coefficient (k) of kinetic equation) as well as occurrence of free cells. It suggests that the operating condition at reactor B with 1.3 C/N ratio is more appropriate for long-term operation at a pilot-scale.

  20. [Effect of Intermittent Aeration on Nitrogen Removal Efficiency in Vertical Subsurface Flow Constructed Wetland].

    PubMed

    Wang, Jian; Li, Huai-zheng; Zhen, Bao-chong; Liu, Zhen-dong

    2016-03-15

    One-stage vertical subsurface flow constructed wetlands (CWs) were used to treat effluent from grit chamber in municipal wastewater treatment plant. The CW was divided into aerobic zone and anoxic zone by means of raising the effluent level and installing a perforated pipe. Two parameters (the ratio of aeration time and nonaeration time, aeration cycle) were optimized in the experiment to enhance nitrogen removal efficiency. The results suggested that the removal rates of COD and NH₄⁺-N increased while TN showed a trend of first increasing and then decreasing with the increasing ratio. When the ratio was 3:1, the C/N value in the anoxic zone was 4. 8. And the TN effluent concentration was 15.8 mg · L⁻¹ with the highest removal rate (62.1%), which was increased by 12.7% compared with continuous aeration. As the extension of the aeration cycle, the DO effluent concentration as well as the removal rates of COD and NH: -N declined gradually. The TN removal rate reached the maximum (65.5%) when the aeration cycle was 6h. However, the TN removal rate dropped rapidly when the cycle exceeded the hydraulic retention time in the anoxic zone. PMID:27337890

  1. Time-related course of pleural space fluid collection and pulmonary aeration on postmortem computed tomography (PMCT).

    PubMed

    Hyodoh, Hideki; Shimizu, Jyunya; Watanabe, Satoshi; Okazaki, Shunichiro; Mizuo, Keisuke; Inoue, Hiromasa

    2015-07-01

    Postmortem CT (PMCT) is increasingly used in forensic practice, and knowledge and classification of typical postmortem imaging findings would facilitate the interpretation of PMCT. The goal of this study was to define the time-related course of postmortem chest findings. Twelve cadavers (eight male, four female, 27-81 [mean, 60.0]years) were examined twice by PMCT within an interval of time (4-164 h [mean, 30.8; median, 17.5]). The pleural-space-fluid volume, pulmonary parenchyma volume, decreased aerated lung volume (DLV), %DLV (=DLV/pulmonary parenchyma volume) and chest cavity volume were compared between the first and second PMCT examinations. To evaluate the volume change rate, the rate of increase in pleural space fluid volume (mL/h) and the DLV rate (mL/h) were plotted according to the postmortem period. On the second PMCT, the volume of pleural space fluid (p=0.0469) and %DLV (p=0.0161) were significantly increased. The increase rate of the pleural space fluid increased at approximately 30 h and the volume continued to increase until approximately 40 h after death. The rate of DLV constantly decreased in the early postmortem period. In conclusion, the pleural-space-fluid collection and the DLV increased over different time-related courses in the postmortem period.

  2. [Effect of intermittent artificial aeration on nitrogen and phosphorus removal in subsurface vertical-flow constructed wetlands].

    PubMed

    Tang, Xian-qiang; Li, Jin-zhong; Li, Xue-Ju; Liu, Xue-gong; Huang, Sui-liang

    2008-04-01

    Shale and T. latifolia were used as subsurface vertical-flow constructed wetland substrate and vegetation for eutrophic Jin River water treatment, and investigate the effect of intermittent aeration on nitrogen and phosphorus removal. In this study, hydraulic loading rate was equal to 800 mm/d, and ratio of air and water was 5:1. During the entire running period, maximal monthly mean ammonia-nitrogen (NH4+ -N), total nitrogen (TN), soluble reactive phosphorus (SRP) and total phosphorus (TP) removal rates were observed in August 2006. In contrast to the non-aerated wetland, aeration enhanced ammonia-nitrogen, total nitrogen, soluble reactive phosphorus and total phosphorus removal: 10.1%, 4.7%, 10.2% and 8.8% for aeration in the middle, and 25.1%, 10.0%, 7.7% and 7.4% for aeration at the bottom of the substrate, respectively. However, aeration failed to improve the nitrate-nitrogen removal. During the whole experimental period, monthly mean NO3(-) -N removal rates were much lower for aerated constructed wetlands (regarding aeration in the middle and at the bottom) than those for non-aerated system. After finishing the experiment, aboveground plant biomass (stems and leaves) of T. latifolia was harvested, and its weight and nutrient content (total nitrogen and total phosphorus) were measured. Analysis of aboveground plant biomass indicated that intermittent aeration restrained the increase in biomass but stimulated assimilation of nitrogen and phosphorus into stems and leaves. Additional total nitrogen removal of 11.6 g x m(-2) and 12.6 g x m(-2) by aboveground T. latifolia biomass for intermittent artificial aeration in the middle and at the bottom of the wetland substrate, respectively, was observed.

  3. Effect of regional lung inflation on ventilation heterogeneity at different length scales during mechanical ventilation of normal sheep lungs.

    PubMed

    Wellman, Tyler J; Winkler, Tilo; Costa, Eduardo L V; Musch, Guido; Harris, R Scott; Venegas, Jose G; Vidal Melo, Marcos F

    2012-09-01

    Heterogeneous, small-airway diameters and alveolar derecruitment in poorly aerated regions of normal lungs could produce ventilation heterogeneity at those anatomic levels. We modeled the washout kinetics of (13)NN with positron emission tomography to examine how specific ventilation (sV) heterogeneity at different length scales is influenced by lung aeration. Three groups of anesthetized, supine sheep were studied: high tidal volume (Vt; 18.4 ± 4.2 ml/kg) and zero end-expiratory pressure (ZEEP) (n = 6); low Vt (9.2 ± 1.0 ml/kg) and ZEEP (n = 6); and low Vt (8.2 ± 0.2 ml/kg) and positive end-expiratory pressure (PEEP; 19 ± 1 cmH(2)O) (n = 4). We quantified fractional gas content with transmission scans, and sV with emission scans of infused (13)NN-saline. Voxel (13)NN-washout curves were fit with one- or two-compartment models to estimate sV. Total heterogeneity, measured as SD[log(10)(sV)], was divided into length-scale ranges by measuring changes in variance of log(10)(sV), resulting from progressive filtering of sV images. High-Vt ZEEP showed higher sV heterogeneity at <12- (P < 0.01), 12- to 36- (P < 0.01), and 36- to 60-mm (P < 0.05) length scales compared with low-Vt PEEP, with low-Vt ZEEP in between. Increased heterogeneity was associated with the emergence of low sV units in poorly aerated regions, with a high correlation (r = 0.95, P < 0.001) between total heterogeneity and the fraction of lung with slow washout. Regional mean fractional gas content was inversely correlated with regional sV heterogeneity at <12- (r = -0.67), 12- to 36- (r = -0.74), and >36-mm (r = -0.72) length scales (P < 0.001). We conclude that sV heterogeneity at length scales <60 mm increases in poorly aerated regions of mechanically ventilated normal lungs, likely due to heterogeneous small-airway narrowing and alveolar derecruitment. PEEP reduces sV heterogeneity by maintaining lung expansion and airway patency at those small length scales.

  4. Towards integrated operation of membrane bioreactors: effects of aeration on biological and filtration performance.

    PubMed

    Dalmau, M; Monclús, H; Gabarrón, S; Rodriguez-Roda, I; Comas, J

    2014-11-01

    Two experimental studies evaluated the effect of aerobic and membrane aeration changes on sludge properties, biological nutrient removal and filtration processes in a pilot plant membrane bioreactor. The optimal operating conditions were found at an aerobic dissolved oxygen set-point (DO) of 0.5 mg O2 L(-1) and a membrane specific aeration demand (SADm) of 1 m h(-1), where membrane aeration can be used for nitrification. Under these conditions, a total flow reduction of 42% was achieved (75% energy reduction) without compromising nutrient removal efficiencies, maintaining sludge characteristics and controlled filtration. Below these optimal operating conditions, the nutrient removal efficiency was reduced, increasing 20% for soluble microbial products, 14% for capillarity suction time and reducing a 15% for filterability. Below this DO set-point, fouling increased with a transmembrane pressure 75% higher. SADm below 1 m h(-1) doubled the values of transmembrane pressure, without recovery after achieving the initial conditions.

  5. Bioethanol production from the hydrolysate of rape stem in a surface-aerated fermentor.

    PubMed

    Yeon, Ji-Hyeon; Lee, Sang-Eun; Choi, Woon Yong; Choi, Won-Seok; Kim, Il-Chul; Lee, Hyeon-Yong; Jung, Kyung-Hwan

    2011-01-01

    In this study, we investigated the feasibility of producing bioethanol from the hydrolysate of rape stem. Specifically, the most ideal yeast strain was screened, and the microaeration was performed by surface aeration on a liquid medium surface. Among the yeast strains examined, Pichia stipitis CBS 7126 displayed the best performance in bioethanol production during the surface-aerated fermentor culture. Pichia stipitis CBS 7126 produced maximally 9.56 g/l of bioethanol from the initial total reducing sugars (about 28 g/l). The bioethanol yield was 0.397 (by the DNS method). Furthermore, this controlled surface aeration method holds promise for use in the bioethanol production from the xylose-containing lignocellulosic hydrolysate of biomass.

  6. Wastewater treatment with bacteria immobilized onto a ceramic carrier in an aerated system.

    PubMed

    Kariminiaae-Hamedaani, Hamid-Reza; Kanda, Kohzo; Kato, Fumio

    2003-01-01

    Biological treatment of the wastewater discharged from a food processing factory was continuously carried out in a packed bed bioreactor under aerobic conditions. The bacterium isolated from the wastewater was immobilized onto a new type of ceramic carrier by a vacuum method and high numbers of bacteria were colonized onto the carrier (2.9 x 10(9) cfu/g of dry ceramic carrier). The effect of the hydraulic retention time (HRT) and aeration rate on the removal of the chemical oxygen demand (COD) was investigated. The system was able on average to remove more than 82% of the influent COD during 160 d of operation and more than 87% of the influent COD on average was removed when the HRT was 30.17 h and the aeration rate was 2.0 vvm. Aeration rates in the range of 0.4 to 2.0 vvm do not affect the COD removal efficiency. PMID:16233380

  7. Recovery of ammonia from swine manure using gas-permeable membranes: effect of aeration.

    PubMed

    García-González, M C; Vanotti, M B; Szogi, A A

    2015-04-01

    The gas-permeable membrane process can recover ammonia from manure, reducing pollution whilst converting ammonia into an ammonium salt fertilizer. The process involves manure pH control to increase ammonium (NH4(+)) recovery rate that is normally carried out using an alkali. In this study a new strategy to avoid the use of alkali was tested applying low-rate aeration and nitrification inhibition. The wastewater used was raw swine manure with 2390 mg NH4(+)-N/L. Results showed that aeration increased pH above 8.5 allowing quick transformation of NH4(+) into gaseous ammonia (NH3) and efficient recovery by permeation through the submerged membrane. The overall NH4(+) recovery obtained with aeration was 98% and ammonia emissions losses were less than 1.5%. The new approach can substitute large amounts of alkali chemicals needed to obtain high NH4(+) recovery with important economic and environmental savings. PMID:25602923

  8. RBF methods for solving laterally averaged Saint Venant equations: application to eutrophication prevention through aeration

    NASA Astrophysics Data System (ADS)

    Halassi, A.; Ouazar, D.; Taik, A.

    2015-10-01

    A vertical 2Dxz laterally averaged hydrodynamic model is presented in this paper to study the aeration process in lakes. The system exhibits highly nonlinear behaviour due to the phenomena involved such as stratification, air concentration, and convective terms. The suggested model is used to simulate mechanical aeration to overcome and prevent the eutrophication in lakes. The multiquadric radial basis functions are used to solve numerically the governing partial differential equations. Because of the difficulty and the complexity when choosing a suitable shape parameter in radial basis functions, an alternative way is introduced in this work to overcome these difficulties. A validation study is carried out using several test examples, including Poisson, Navier-Stokes and transport equations. Finally, the proposed model is first applied to simulate a squared domain aeration problem and then a real test case has been considered. The obtained results are in good agreement with the results reported in the literature.

  9. Greenhouse gas production and efficiency of planted and artificially aerated constructed wetlands.

    PubMed

    Maltais-Landry, Gabriel; Maranger, Roxane; Brisson, Jacques; Chazarenc, Florent

    2009-03-01

    Greenhouse gas (GHG) emissions by constructed wetlands (CWs) could mitigate the environmental benefits of nutrient removal in these man-made ecosystems. We studied the effect of 3 different macrophyte species and artificial aeration on the rates of nitrous oxide (N(2)O), carbon dioxide (CO(2)) and methane (CH(4)) production in CW mesocosms over three seasons. CW emitted 2-10 times more GHG than natural wetlands. Overall, CH(4) was the most important GHG emitted in unplanted treatments. Oxygen availability through artificial aeration reduced CH(4) fluxes. Plant presence also decreased CH(4) fluxes but favoured CO(2) production. Nitrous oxide had a minor contribution to global warming potential (GWP<15%). The introduction of oxygen through artificial aeration combined with plant presence, particularly Typha angustifolia, had the overall best performance among the treatments tested in this study, including lowest GWP, greatest nutrient removal, and best hydraulic properties.

  10. Bioremediation of 2,4,6-trinitrotoluene-contaminated soils by two different aerated compost systems.

    PubMed

    Breitung, J; Bruns-Nagel, D; Steinbach, K; Kaminski, L; Gemsa, D; von Löw, E

    1996-02-01

    Two composting systems were compared on a laboratory scale as a bioremediation technology for degradation or immobilization of 2,4,6-trinitrotoluene (TNT) in contaminated soils. The first compost was aerated from the beginning whereas the second compost was only aerated after an anaerobic prephase of 65 days. In the first compost system the TNT concentration declined rapidly by 92% but, at the end, TNT could be partially recovered. During the anaerobic prephase of the second compost system, TNT was almost completely converted to aminodinitrotoluenes, which during the subsequent aeration almost entirely disappeared. In addition, the second compost generated less toxic material than the first one as confirmed by inhibition of bioluminescence of Vibrio fischeri. These data show that microbiological TNT-degradation systems can be successfully designed which are prerequisite for an efficient bioremediation of contaminated soils.

  11. Response of the ascorbate-glutathione cycle to re-aeration following hypoxia in lupine roots.

    PubMed

    Garnczarska, Małgorzata

    2005-06-01

    The response of the enzymes and metabolites of the ascorbate-glutathione pathway to oxidative stress caused by re-aeration following hypoxia was studied in roots of hydroponically grown lupine (Lupinus luteus L. cv. Juno) seedlings. Lupine roots were deprived of oxygen by subjecting them to hypoxia for 48 and 72 h and then re-aerated for up to 4 h. An increased content of total ascorbate was observed in lupine roots immediately after hypoxia, whereas total glutathione level decreased. However, a significant increase in the reduced forms of both metabolites was found directly after hypoxia. Re-admission of oxygen caused the decrease of the ratios of reduced to oxidized forms of ascorbate and glutathione, indicating oxidative stress. While monodehydroascorbate reductase (MDHAR, EC 1.6.5.4) activity remained unaltered during re-aeration the increase in activities of ascorbate peroxidase (APX, EC 1.11.1.11) and glutathione reductase (GR, EC 1.6.4.2) was observed 30 min after transfer from hypoxic condition. Dehydroascorbate reductase (DHAR, EC 1.8.5.1) activity approached the control level during a whole re-aeration period. Native gel electrophoresis combined with specific activity staining revealed seven isoforms of APX, five isoforms of GR and three different proteins with DHA reductase activity in roots extracts. However, immediately after hypoxic treatment APX-5 isoform and GR-1 isoform were not observed in roots. This experimental system was also used to investigate superoxide anion level in roots utilizing the superoxide anion-specific indicator dihydroethidium (DHE). Intense DHE-derived fluorescence was found in re-aerated root tips as compared to control roots, indicating that re-aeration induced superoxide anion production in hypoxically pretreated roots.

  12. Volatile emissions during storing of green food waste under different aeration conditions.

    PubMed

    Agapiou, A; Vamvakari, J P; Andrianopoulos, A; Pappa, A

    2016-05-01

    Controlled field experiments were carried out for monitoring the emissions of three plastic commercial household waste bins, which were adapted for studying the effect of aeration process in the evolved volatiles, during house storing of green food waste for 2 weeks, prior to collection. Three experimental scenarios were examined based on no aeration ("NA," closed commercial waste bin), diffusion-based aeration ("DA," closed commercial waste bin with tiny holes), and enforced aeration ("EA," closed commercial waste bin with tiny holes and enforced aeration). The monitoring of volatile organic compounds (VOCs) emitted from organic household kitchen waste was performed using solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) analysis. Portable sensors were also used for monitoring selected gases and parameters of environmental, bioprocess, and health interest (e.g., CO2, O2, H2S, CH4, NH3, % RH, waste temperatures). VOC emissions are strongly dependent on the waste material. The most frequent VOCs identified over the storing waste, showing over 50 % appearance in all examined samples, were terpenes (e.g., di-limonene, beta-myrcene, delta-3-carene, alpha-pinene, alpha-terpinolene, linalool, etc.), sulfides (dimethyl disulfide), aromatics (benzene, 1-methyl-2-(2-propenyl)), alkanes (e.g., decane, dodecane), ketones (2-propanone), esters (e.g., acetic acid ethyl ester, acetic acid methyl ester), and alcohols (e.g., 3-cyclohexen-1-ol, 4-methyl-1-(1-methylethyl)). The prominent role of terpenes in the "pre-compost" odor and especially that of di-limonene was highlighted. In all examined scenarios, the emitted volatiles were increased at raised temperatures and later decreased in time. Aeration of waste bins slightly affected the volatilization process resulting in higher profiles of VOCs; uniformity in the composition of VOCs was also noted. Slight modifications of commercial waste bins may favor the initiation of home composting. PMID

  13. Relationship between ecosystem respiration and aeration constant in open channel dissolved oxygen analysis

    NASA Astrophysics Data System (ADS)

    Parker, S. J.; Butler, A. P.; Heppell, C. M.

    2015-12-01

    Using the open channel diel method of Odum (1956) and the night-time regression method (Hornberger and Kelly, 1985), we analysed a time series of dissolved oxygen (DO) in two slow flowing streams for a two month period in summer 2014 and obtained values for ecosystem respiration and the aeration constant for each day in the period. We then used the standard dissolved oxygen lumped model to generate a DO time series behaviour for one of those rivers selecting respiration and aeration parameters by randomly sampling from the values obtained from the data. Two synthetic time series were created, one where respiration and aeration were independent of temperature and a second where respiration and aeration were affected by temperature according to the modified Arrhenius relationship. With these two synthetic time series, we again recovered the respiration and aeration input parameters using the night- time regression method and compared those recovered parameters with the input parameters. Because the simulations were conducted with parameters that were known, the values recovered using the night-time regression method (i.e post-simulation) could be compared with parameters driving the simulation (i.e. pre-simulation input values). For values based on data, we found a strong correlation between the aeration constant and respiration for both rivers. For the synthetic time series, no such correlation was found, either with the temperature independent or temperature dependent time series. The night-time regression method also recovered perfectly the input parameters, so the correlation was not brought about as a result of implementing the method itself. We are currently investigating the cause of the correlation.

  14. Volatile emissions during storing of green food waste under different aeration conditions.

    PubMed

    Agapiou, A; Vamvakari, J P; Andrianopoulos, A; Pappa, A

    2016-05-01

    Controlled field experiments were carried out for monitoring the emissions of three plastic commercial household waste bins, which were adapted for studying the effect of aeration process in the evolved volatiles, during house storing of green food waste for 2 weeks, prior to collection. Three experimental scenarios were examined based on no aeration ("NA," closed commercial waste bin), diffusion-based aeration ("DA," closed commercial waste bin with tiny holes), and enforced aeration ("EA," closed commercial waste bin with tiny holes and enforced aeration). The monitoring of volatile organic compounds (VOCs) emitted from organic household kitchen waste was performed using solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) analysis. Portable sensors were also used for monitoring selected gases and parameters of environmental, bioprocess, and health interest (e.g., CO2, O2, H2S, CH4, NH3, % RH, waste temperatures). VOC emissions are strongly dependent on the waste material. The most frequent VOCs identified over the storing waste, showing over 50 % appearance in all examined samples, were terpenes (e.g., di-limonene, beta-myrcene, delta-3-carene, alpha-pinene, alpha-terpinolene, linalool, etc.), sulfides (dimethyl disulfide), aromatics (benzene, 1-methyl-2-(2-propenyl)), alkanes (e.g., decane, dodecane), ketones (2-propanone), esters (e.g., acetic acid ethyl ester, acetic acid methyl ester), and alcohols (e.g., 3-cyclohexen-1-ol, 4-methyl-1-(1-methylethyl)). The prominent role of terpenes in the "pre-compost" odor and especially that of di-limonene was highlighted. In all examined scenarios, the emitted volatiles were increased at raised temperatures and later decreased in time. Aeration of waste bins slightly affected the volatilization process resulting in higher profiles of VOCs; uniformity in the composition of VOCs was also noted. Slight modifications of commercial waste bins may favor the initiation of home composting.

  15. Performance evaluation of a aerated lagoon under summer and winter conditions

    SciTech Connect

    Surampalli, R.Y.; Ninaroon, S.; Banerji, S.K.

    1998-07-01

    A one-year study evaluated the performance of a full-scale aerated lagoon, located in the Midwest, under winter and summer conditions. The objective of this study was mainly to evaluate the affect of temperature on BOD{sub 5}, suspended solids, and ammonia nitrogen removal. Influent and effluent samples were collected, for one-year, from this aerated lagoon system. The collected (monthly grab) influent and effluent samples were analyzed for BOD{sub 5}, suspended solids, ammonia nitrogen, organic nitrogen, nitrite nitrogen, and nitrate nitrogen. In addition, samples were also analyzed for total phosphorus, total alkalinity, dissolved oxygen, pH, E. Coli, fecal coliforms and temperature.

  16. Lung B-line artefacts and their use

    PubMed Central

    Mathis, Gebhard; Blaivas, Michael; Volpicelli, Giovanni; Seibel, Armin; Wastl, Daniel; Atkinson, Nathan S. S.; Cui, Xin-Wu; Fan, Mei; Yi, Dong

    2016-01-01

    Background The analysis of lung artefacts has gained increasing importance as markers of lung pathology. B-line artefact (BLA), caused by a reverberation phenomenon, is the most important lung artefact. In this review, we discuss the current role of BLA in pneumology and explore open questions of the published consensus. Methods We summarized current literature about BLA. Also, we presented observations on healthy subjects and patients with interstitial syndrome (pulmonary fibrosis and edema), to investigate technical factors influencing BLA visualization. Results BLA imaging is influenced by more factors than recently assumed. When multiple BLA is visualized in the lung, they represent a sign of increased density due to the loss of aeration in the lung periphery. This condition may indicate different diseases including cardiogenic pulmonary edema, diffuse or focal interstitial lung diseases (ILD), infections and acute respiratory distress syndrome (ARDS). Correct interpretation of BLA in lung ultrasound is strongly influenced by associated sonographic signs and careful integration of all relevant clinical information. Conclusions BLA is useful to monitor clinical response, and may become crucial in directing the diagnostic process. Further research is warranted to clarify technical adjustments, different probe and machine factors that influence the visualization of BLA. PMID:27293860

  17. Pathways of nitrobenzene degradation in horizontal subsurface flow constructed wetlands: Effect of intermittent aeration and glucose addition.

    PubMed

    Kirui, Wesley K; Wu, Shubiao; Kizito, Simon; Carvalho, Pedro N; Dong, Renjie

    2016-01-15

    Intermittent aeration and addition of glucose were applied to horizontal subsurface flow constructed wetlands in order to investigate the effect on pathways of nitrobenzene (NB) degradation and interactions with microbial nitrogen and sulphur transformations. The experiment was carried out in three phases A, B and C consisting of different NB loading and glucose dosing. For each phase, the effect of aeration was assessed by intermittently aerating one wetland and leaving one unaerated. Regardless of whether or not the wetland was aerated, at an influent NB concentration of 140 mg/L, both wetlands significantly reduced NB to less than 2 mg/L, a reduction efficiency of 98%. However, once the influent NB concentration was increased to 280 mg/L, the aerated wetland had a higher removal performance 82% compared to that of the unaerated wetland 71%. Addition of glucose further intensified the NB removal to 95% in the aerated wetlands and 92% in the unaerated. Aeration of wetlands enhanced NB degradation, but also resulted in higher NB volatilization of 6 mg m(-2) d(-1). The detected high concentration of sulphide 20-60 mg/L in the unaerated wetland gave a strong indication that NB may act as an electron donor to sulphate-reducing bacteria, but this should be further investigated. Aeration positively improved NB removal in constructed wetlands, but resulted in higher NB volatilization. Glucose addition induced co-metabolism to enhance NB degradation. PMID:26468606

  18. Pathways of nitrobenzene degradation in horizontal subsurface flow constructed wetlands: Effect of intermittent aeration and glucose addition.

    PubMed

    Kirui, Wesley K; Wu, Shubiao; Kizito, Simon; Carvalho, Pedro N; Dong, Renjie

    2016-01-15

    Intermittent aeration and addition of glucose were applied to horizontal subsurface flow constructed wetlands in order to investigate the effect on pathways of nitrobenzene (NB) degradation and interactions with microbial nitrogen and sulphur transformations. The experiment was carried out in three phases A, B and C consisting of different NB loading and glucose dosing. For each phase, the effect of aeration was assessed by intermittently aerating one wetland and leaving one unaerated. Regardless of whether or not the wetland was aerated, at an influent NB concentration of 140 mg/L, both wetlands significantly reduced NB to less than 2 mg/L, a reduction efficiency of 98%. However, once the influent NB concentration was increased to 280 mg/L, the aerated wetland had a higher removal performance 82% compared to that of the unaerated wetland 71%. Addition of glucose further intensified the NB removal to 95% in the aerated wetlands and 92% in the unaerated. Aeration of wetlands enhanced NB degradation, but also resulted in higher NB volatilization of 6 mg m(-2) d(-1). The detected high concentration of sulphide 20-60 mg/L in the unaerated wetland gave a strong indication that NB may act as an electron donor to sulphate-reducing bacteria, but this should be further investigated. Aeration positively improved NB removal in constructed wetlands, but resulted in higher NB volatilization. Glucose addition induced co-metabolism to enhance NB degradation.

  19. Functional linkage between N acquisition strategies and aeration capacities of hydrophytes for efficient oxygen consumption in roots.

    PubMed

    Nakamura, Motoka; Nakamura, Takatoshi; Tsuchiya, Takayoshi; Noguchi, Ko

    2013-02-01

    We evaluated the specific strategies of hydrophytes for root O(2) consumption in relation to N acquisition and investigated whether the strategies varied depending on the aeration capacity. Aeration capacity of roots is an important factor for determining hypoxia tolerance in plants. However, some hydrophytes possessing quite different aeration capacities often co-occur in wetlands, suggesting that root O(2) consumption also strongly affects hypoxia tolerance. We cultivated Phragmites australis with high aeration capacity and Zizania latifolia with low aeration capacity in hypoxic conditions with NH(4)(+) or NO(3)(-) treatment and compared the growth, N uptake, N assimilation and root respiration between the two species. In Z. latifolia grown with NH(4)(+) treatment, high N uptake activity and restrained root growth led to sufficient N acquisition and decrease in whole-root respiration rate. These characteristics consequently compensated for the low aeration capacity. In contrast, in P. australis, low N uptake activity was compensated by active root growth, but the whole-root respiration rate was high. This high root respiration rate was allowed by the high aeration capacity. The O(2) consumption-related traits of hydrophyte roots were closely correlated with N acquisition strategies, which consequently led to a compensational relationship with the root aeration capacity. It is likely that this functional linkage plays an important role as a core mechanism in the adaptation of plants to hypoxic soils.

  20. Functional linkage between N acquisition strategies and aeration capacities of hydrophytes for efficient oxygen consumption in roots.

    PubMed

    Nakamura, Motoka; Nakamura, Takatoshi; Tsuchiya, Takayoshi; Noguchi, Ko

    2013-02-01

    We evaluated the specific strategies of hydrophytes for root O(2) consumption in relation to N acquisition and investigated whether the strategies varied depending on the aeration capacity. Aeration capacity of roots is an important factor for determining hypoxia tolerance in plants. However, some hydrophytes possessing quite different aeration capacities often co-occur in wetlands, suggesting that root O(2) consumption also strongly affects hypoxia tolerance. We cultivated Phragmites australis with high aeration capacity and Zizania latifolia with low aeration capacity in hypoxic conditions with NH(4)(+) or NO(3)(-) treatment and compared the growth, N uptake, N assimilation and root respiration between the two species. In Z. latifolia grown with NH(4)(+) treatment, high N uptake activity and restrained root growth led to sufficient N acquisition and decrease in whole-root respiration rate. These characteristics consequently compensated for the low aeration capacity. In contrast, in P. australis, low N uptake activity was compensated by active root growth, but the whole-root respiration rate was high. This high root respiration rate was allowed by the high aeration capacity. The O(2) consumption-related traits of hydrophyte roots were closely correlated with N acquisition strategies, which consequently led to a compensational relationship with the root aeration capacity. It is likely that this functional linkage plays an important role as a core mechanism in the adaptation of plants to hypoxic soils. PMID:22575011

  1. The effect of aeration position on the spatial distribution and reduction of pollutants in the landfill stabilization process--a pilot scale study.

    PubMed

    Chai, Xiaoli; Hao, Yongxia; Shimaoka, Takayuki; Nakayama, Hirofumi; Komiya, Teppei; Zhao, Youcai

    2013-01-01

    Three pilot-scale simulators with different aeration systems were constructed to explore the effects of aeration position on the reduction of pollutants. The simulator with a bottom aeration system successfully distributed oxygen and efficiently inhibited methane production. A close relationship was found between the oxygen distribution and the removal of pollutants, especially that of nitrogen. The transition between nitrification and denitrification in the longitude direction of the simulator with a bottom aeration system contributed to nitrogen removal in aerobic conditions. This process can be defined as a new path for nitrogen removal in addition to simultaneous nitrification and denitrification. The concentration of NH4+ -N total nitrogen and total organic carbon dropped to 3, 78 and 204 mg L(-1), respectively, after 312 days of bottom aeration and to 514, 659 and 828 mg L(-1), respectively, after 312 days of top aeration. These results indicate that the bottom aeration system was more efficient for reducing pollutants than the top aeration system.

  2. Dynamic measures of regional lung air volume using phase contrast x-ray imaging

    NASA Astrophysics Data System (ADS)

    Kitchen, M. J.; Lewis, R. A.; Morgan, M. J.; Wallace, M. J.; Siew, M. L.; Siu, K. K. W.; Habib, A.; Fouras, A.; Yagi, N.; Uesugi, K.; Hooper, S. B.

    2008-11-01

    Phase contrast x-ray imaging can provide detailed images of lung morphology with sufficient spatial resolution to observe the terminal airways (alveoli). We demonstrate that quantitative functional and anatomical imaging of lung ventilation can be achieved in vivo using two-dimensional phase contrast x-ray images with high contrast and spatial resolution (<100 µm) in near real time. Changes in lung air volume as small as 25 µL were calculated from the images of term and preterm rabbit pup lungs (n = 28) using a single-image phase retrieval algorithm. Comparisons with plethysmography and computed tomography showed that the technique provided an accurate and robust method of measuring total lung air volumes. Furthermore, regional ventilation was measured by partitioning the phase contrast images, which revealed differences in aeration for different ventilation strategies.

  3. Nitrification cessation and recovery in an aerated saturated vertical subsurface flow treatment wetland: Field studies and microscale biofilm modeling.

    PubMed

    Murphy, Clodagh; Rajabzadeh, Amin R; Weber, Kela P; Nivala, Jaime; Wallace, Scott D; Cooper, David J

    2016-06-01

    In aerated treatment wetlands, oxygen availability is not a limiting factor in sustaining a high level of nitrification in wastewater treatment. In the case of an air blower failure, nitrification would cease, potentially causing adverse effects to the nitrifying bacteria. A field trial was completed investigating nitrification loss when aeration is switched off, and the system recovery rate after the aeration is switched back on. Loss of dissolved oxygen was observed to be more rapid than loss of nitrification. Nitrate was observed in the effluent long after the aeration was switched off (48h+). A complementary modeling study predicted nitrate diffusion out of biofilm over a 48h period. After two weeks of no aeration in the established system, nitrification recovered within two days, whereas nitrification establishment in a new system was previously observed to require 20-45days. These results suggest that once established resident nitrifying microbial communities are quite robust. PMID:26967335

  4. Performance of organics and nitrogen removal in subsurface wastewater infiltration systems by intermittent aeration and shunt distributing wastewater.

    PubMed

    Pan, Jing; Yuan, Fang; Yu, Long; Huang, Linli; Fei, Hexin; Cheng, Fan; Zhang, Qi

    2016-07-01

    Organics and nitrogen removal in four subsurface wastewater infiltration systems (SWISs), named SWIS A (without intermittent aeration and shunt distributing wastewater), SWIS B (with intermittent aeration), SWIS C (with shunt distributing wastewater) and SWIS D (with intermittent aeration and shunt distributing wastewater) was investigated. High average removal rates of 92.3% for COD, 90.2% for NH4-N and 88.1% for TN were achieved simultaneously in SWIS D compared with SWIS A, B and C. The excellent TN removal of SWIS D was due to intermittent aeration provided sufficient oxygen for nitrification in upper matrix and the favorable anoxic or anaerobic environment for denitrification in subsequent matrix, and moreover, shunt distributing wastewater provided sufficient carbon source for denitrification process. The results indicated that intermittent artificial aeration combined with shunt distributing wastewater could achieve high organics and nitrogen removal in SWISs.

  5. Lung ultrasound: Present and future.

    PubMed

    Saraogi, Ashish

    2015-01-01

    The scope of lung ultrasound (LUS) in emergency and critical care settings has been studied extensively. LUS is easily available at bedside, free of radiation hazard and real time. All these features make it useful in reducing need of bedside X-rays and CT scan of chest. LUS has been proven to be superior to the bedside chest X-ray and equal to chest CT in diagnosing many pleural and lung pathologies. The first International Consensus Conference on Lung Ultrasound (ICC-LUS) has given recommendations for unified approach and language in major six areas of LUS. The LUS diagnosis is to be given after integration of findings of both lungs. The BLUE protocol is first LUS-based systematic approach in diagnosing pleural and lung pathologies. The protocol suggested in this article includes history and conventional clinical assessment along with LUS features. PMID:25983411

  6. Treatment of landfill leachate using an aerated, horizontal subsurface-flow constructed wetland.

    PubMed

    Nivala, J; Hoos, M B; Cross, C; Wallace, S; Parkin, G

    2007-07-15

    A pilot-scale subsurface-flow constructed wetland was installed at the Jones County Municipal Landfill, near Anamosa, Iowa, in August 1999 to demonstrate the use of constructed wetlands as a viable low-cost treatment option for leachate generated at small landfills. The system was equipped with a patented wetland aeration process to aid in removal of organic matter and ammonia nitrogen. The high iron content of the leachate caused the aeration system to cease 2 years into operation. Upon the installation of a pretreatment chamber for iron removal and a new aeration system, treatment efficiencies dramatically improved. Seasonal performance with and without aeration is reported for 5-day biochemical oxygen demand (BOD(5)), chemical oxygen demand (COD), ammonia nitrogen (NH(4)-N), and nitrate nitrogen (NO(3)-N). Since winter air temperatures in Iowa can be very cold, a layer of mulch insulation was installed on top of the wetland bed to keep the system from freezing. When the insulation layer was properly maintained (either through sufficient litterfall or replenishing the mulch layer), the wetland sustained air temperatures of as low as -26 degrees C without freezing problems.

  7. Improvement of anaerobic digester performance by wastewater recirculation through an aerated membrane.

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Swine wastewater from an anaerobic digester was recirculated through a silicone hose located in an external aeration chamber to determine its effect on wastewater malodorants and biogas composition. The silicone hose acted as a semipermeable membrane for the passage of small molecules. In the first...

  8. Effect of agitation and aeration on the citric acid production by Yarrowia lipolytica grown on glycerol.

    PubMed

    Rywińska, Anita; Musiał, Izabela; Rymowicz, Waldemar; Zarowska, Barbara; Boruczkowski, Tomasz

    2012-01-01

    The effects of agitation rates from 400 to 900 rpm and aeration rates ranging from 0.18 to 0.6 vvm on biomass and citric acid production on glycerol media by acetate-negative mutants of Yarrowia lipolytica, Wratislavia 1.31 and Wratislavia AWG7, in batch culture were studied. The agitation rates of 800 and 900 rpm (at a constant aeration rate of 0.36 vvm) and aeration rates within the range of 0.24-0.48 vvm (at a constant agitation rate of 800 rpm), which generated dissolved oxygen concentration (DO) higher than 40%, were found the best for citric acid biosynthesis from glycerol. An increase in agitation rate (higher than 800 rpm) and aeration rate (higher than 0.36 vvm) had no impact on DO and citric acid production. The highest citric acid concentration (92.8 g/L) and yield (0.63 g/g) were obtained with Wratislavia 1.31 strain at 0.24 vvm. The highest volumetric citric acid production rate (1.15 g/Lh) and specific citric acid production rate (0.071 g/gh) were reached at 0.48 vvm.

  9. 72. (Credit LSU) Aerator in settling basin south of McNeil ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    72. (Credit LSU) Aerator in settling basin south of McNeil Pumping Station c1907. (Louisiana State University in Shreveport Archives, post card collection) - McNeil Street Pumping Station, McNeil Street & Cross Bayou, Shreveport, Caddo Parish, LA

  10. Flow, aeration, and carbon dioxide transfer rates for airlifts used in recirculating aquaculture systems

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Airlift pumping systems reduce the electrical costs of moving water in a recirculating aquaculture system and can be concurrently designed to aerate water and remove carbon dioxide. This study determined the water flow, oxygen transfer, and CO2 removal rates for water using airlift technology in a 1...

  11. Evaluation of cost-effective aeration technology solutions to address total trihalomethane (TTHM) compliance

    EPA Science Inventory

    The primary objective of this project was to evaluate cost-effective aeration technology solutions to address TTHM compliance at a water treatment plant clearwell. The project team worked closely with EPA Region 6 and the EPA Office of Research and Development (ORD) to identify a...

  12. [Technological characteristics of bioreactor landfill with aeration in the upper layer].

    PubMed

    Tian, Ying; Wang, Shen; Xu, Qi-Yong

    2014-11-01

    In order to study the effects of upper-layer aerobic pretreatment in bioreactors on refuse degradation, leachate condition and methane production, two simulated columns were constructed, including traditional anaerobic bioreactor A1 and hybrid bioreactor C1 with aeration pretreatment in the upper layer. Results indicated that A1 was seriously inhibited by the accumulation of volatile fatty acids (VFA) with nearly no methane production and slower settlements. At the end of operations, refuse in A1 only deposited 5.4 cm which was less than half of that in C1. And up to 70 000 mg x L(-1) COD and 30 000 mg x L(-1) VFA could be monitored in the leachate. On the contrary, aerobic pretreatment effectively improved the removal of high VFA concentrations and remarkably accelerated the degradation rate. In bioreactor C1, COD and VFA concentrations were reduced to less than 14000 mg x L(-1) and 8900 mg x L(-1) at the end of the experiment, respectively. And about 61 976 mL methane gases were produced since aeration ceased on day 60 with its methane recovery efficiency rising to over 95%. However, the performance of hybrid bioreactors was still closely related to its operation conditions, such as aeration supply and leachate recirculation. Therefore, in order to guarantee better performance, appropriate aeration and leachate operations need to be provided.

  13. Processes to improve energy efficiency during pumping and aeration of recirculating water in circular tank systems

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Conventional gas transfer technologies for aquaculture systems occupy a large amount of space, require considerable capital investment, and can contribute to high electricity demand. In addition, diffused aeration in a circular tank can interfere with the hydrodynamics of water rotation and the spee...

  14. Combination of methoprene and controlled aeration to manage insects in stored wheat

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The insect growth regulator methoprene, in the commercial formulation Diacon II®, was applied to wheat stored in small bins either alone or in combination with controlled aeration of the bins to lower grain temperature for insect pest management of stored wheat. Grain temperatures and monitored and ...

  15. Gas transfer rates from airlifts used for concurrent aeration, carbon dioxide stripping, and recirculation

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Airlifts simplify recirculating aquaculture systems and can potentially reduce capital costs and minimize maintenance issues. Airlifts have the ability to move and aerate water as well as degass the water of any carbon dioxide. This study evaluated the oxygen transfer and carbon dioxide removal abil...

  16. Effects of aeration intensity on formation of phenol-fed aerobic granules and extracellular polymeric substances.

    PubMed

    Adav, Sunil S; Lee, Duu-Jong; Lai, J Y

    2007-11-01

    Effect of air aeration intensities on granule formation and extracellular polymeric substances content in three identical sequential batch reactors were investigated. The excitation-emission-matrix spectra and multiple staining and confocal laser scanning microscope revealed proteins, polysaccharides, lipids, and humic substances in the sludge and granule samples. Seed sludge flocs were compacted at low aeration rate, with produced extracellular polymeric substances of 50.2-76.7 mg g(-1) of proteins, 50.2-77.3 mg g(-1) carbohydrates and 74 mg g(-1) humic substances. High aeration rate accelerated formation of 1.0-1.5 mm granules with smooth outer surface. The corresponding quantities of extracellular polymeric substances were 309-537 mg g(-1) of proteins, 61-109 mg g(-1) carbohydrates, 49-92 mg g(-1) humic substances, and 49-68 mg g(-1) lipids. Intermediate aeration rate produced 3.0-3.5 mm granules with surface filaments. Reactor failure occurred with overgrowth of filaments, probably owing to the deficiency of nutrient in liquid phase. No correlation was noted between extracellular polymeric substances composition and the proliferation of filamentous microorganisms on granule surface.

  17. EVALUATING THE COSTS OF PACKED-TOWER AERATION AND GAC FOR CONTROLLING SELECTED ORGANICS

    EPA Science Inventory

    This article focuses on a preliminary cost analysis that compares liquid-phase granular activated carbon (GAC) treatment with packed-tower aeration (PTA) treatment, with and without air emissions control. The sensitivity of cost to design and operating variables is also discussed...

  18. Integral parameters for characterizing water, energy, and aeration properties of soilless plant growth media

    NASA Astrophysics Data System (ADS)

    Chamindu Deepagoda, T. K. K.; Chen Lopez, Jose Choc; Møldrup, Per; de Jonge, Lis Wollesen; Tuller, Markus

    2013-10-01

    Over the last decade there has been a significant shift in global agricultural practice. Because the rapid increase of human population poses unprecedented challenges to production of an adequate and economically feasible food supply for undernourished populations, soilless greenhouse production systems are regaining increased worldwide attention. The optimal control of water availability and aeration is an essential prerequisite to successfully operate plant growth systems with soilless substrates such as aggregated foamed glass, perlite, rockwool, coconut coir, or mixtures thereof. While there are considerable empirical and theoretical efforts devoted to characterize water retention and aeration substrate properties, a holistic, physically-based approach considering water retention and aeration concurrently is lacking. In this study, the previously developed concept of integral water storage and energy was expanded to dual-porosity substrates and an analog integral oxygen diffusivity parameter was introduced to simultaneously characterize aeration properties of four common soilless greenhouse growth media. Integral parameters were derived for greenhouse crops in general, as well as for tomatoes. The integral approach provided important insights for irrigation management and for potential optimization of substrate properties. Furthermore, an observed relationship between the integral parameters for water availability and oxygen diffusivity can be potentially applied for the design of advanced irrigation and management strategies to ensure stress-free growth conditions, while conserving water resources.

  19. Effect of the aerated structure on selected properties of freeze-dried hydrocolloid gels

    NASA Astrophysics Data System (ADS)

    Ciurzyńska, Agnieszka; Lenart, Andrzej

    2016-01-01

    The ability to create diverse structures and studies on the effect of the aerated structure on selected properties with the use of freeze-dried gels may provide knowledge about the properties of dried foods. Such gels can be a basis for obtaining innovative food products. For the gel preparation, 3 types of hydrocolloids were used: low-methoxyl pectin, a mixture of xanthan gum and locust-bean gum, and a mixture of xanthan gum and guar gum. Gels were aerated for 3 and 7 min, frozen at a temperature of -45°C 2 h-1, and freeze-dried at a temperature of 30°C. For the samples obtained, structure, porosity, shrinkage, rehydration, and colour were investigated. It was shown that the type of the hydrocolloid and aeration time influence the structure of freeze-dried gels, which determines such properties of samples as porosity, shrinkage, density, rehydration, and colour. The bigger pores of low-methoxyl pectin gels undergo rehydration in the highest degree. The delicate and aerated structure of gels with the mixture of xanthan gum and locust-bean gum was damaged during freeze-drying and shrinkage exhibited the highest value. Small pores of samples with the mixture of xanthan gum and guar gum were responsible for the lower rehydration properties, but the highest porosity value contributed to the highest lightness value.

  20. Optimization of micro-aeration intensity in acidogenic reactor of a two-phase anaerobic digester treating food waste

    SciTech Connect

    Xu, Suyun; Selvam, Ammaiyappan; Wong, Jonathan W.C.

    2014-02-15

    Highlights: • Effect of micro-aeration on acidogenesis and hydrolysis of food waste was investigated. • Micro-aeration at 258 L-air/kg TS/d increased the VFAs production 3-fold. • High aeration leads to loss of substrate through microbial biomass and respiration. • Optimum aeration increased methane recovery while high aeration intensity reduced methane yield. - Abstract: Micro-aeration is known to promote the activities of hydrolytic exo-enzymes and used as a strategy to improve the hydrolysis of particulate substrate. The effect of different micro-aeration rates, 0, 129, 258, and 387 L-air/kg TS/d (denoted as LBR-AN, LBR-6h, LBR-3h and LBR-2h, respectively) on the solubilization of food waste was evaluated at 35 °C in four leach bed reactors (LBR) coupled with methanogenic upflow anaerobic sludge blanket (UASB) reactor. Results indicate that the intensity of micro-aeration influenced the hydrolysis and methane yield. Adequate micro-aeration intensity in LBR-3h and LBR-2h significantly enhanced the carbohydrate and protein hydrolysis by 21–27% and 38–64% respectively. Due to the accelerated acidogenesis, more than 3-fold of acetic acid and butyric acid were produced in LBR-3h as compared to the anaerobic treatment LBR-AN resulting in the maximum methane yield of 0.27 L CH{sub 4}/g VS{sub added} in the UASB. The performance of LBR-6h with inadequate aeration was similar to that of LBR-AN with a comparable hydrolysis degree. Nevertheless, higher aeration intensity in LBR-2h was also unfavorable for methane yield due to significant biomass generation and CO{sub 2} respiration of up to 18.5% and 32.8% of the total soluble hydrolysate, respectively. To conclude, appropriate micro-aeration rate can promote the hydrolysis of solid organic waste and methane yield without undesirable carbon loss and an aeration intensity of 258 L-air/kg TS/d is recommended for acidogenic LBR treating food waste.

  1. Impact of intermittent aerations on leachate quality and greenhouse gas reduction in the aerobic-anaerobic landfill method.

    PubMed

    Nag, Mitali; Shimaoka, Takayuki; Komiya, Teppei

    2016-09-01

    The aerobic-anaerobic landfill method (AALM) is a novel approach in solid waste management that could shorten the landfill post-closure period and minimize the environmental loads. In this study, the aerobic-anaerobic landfill method was evaluated by using intermittent aeration. In addition, the nitrification-denitrification process was assessed as a means of reducing the emission of greenhouse gases (GHGs) and improving the leachate quality during the degradation of the organic solid waste. The leachate quality and the gas composition in each of the reactors were measured during the experimental period (408days). The aeration process entailed the injection of air into plexiglass cylinders (200cm height×10 cm diameter), filled with fresh organic solid waste collected from a composting plant. Different aeration routines were applied, namely, continuous aeration (aerobic reactor A), aeration for three days/week (aerobic-anaerobic reactor B), aeration for 6h/day (aerobic-anaerobic reactor C), and no aeration (non-aerated reactor D). It was found that aerobic reactor A produced the best results in terms of reduction of GHGs and improvement of the leachate quality. The aerobic-anaerobic reactor C was found to be more effective than reactor B in respect of both the emission of GHGs and the leachate quality; moreover, compared with aerobic reactor A, energy costs were reduced by operating this reactor. The transition period phenomenon was investigated during an intensive seven-day experiment conducted on the discharged leachate obtained from aerobic-anaerobic reactors B and C. The experiment concerned the differences in the composition of the gas during the aeration and the non-aeration periods. It was found that the transition period between the aeration and non-aeration cycles, which followed the simultaneous nitrification-denitrification had a considerable effect on the leachate quality of both the reactors. The results indicated that AALM has the potential to reduce

  2. Impact of intermittent aerations on leachate quality and greenhouse gas reduction in the aerobic-anaerobic landfill method.

    PubMed

    Nag, Mitali; Shimaoka, Takayuki; Komiya, Teppei

    2016-09-01

    The aerobic-anaerobic landfill method (AALM) is a novel approach in solid waste management that could shorten the landfill post-closure period and minimize the environmental loads. In this study, the aerobic-anaerobic landfill method was evaluated by using intermittent aeration. In addition, the nitrification-denitrification process was assessed as a means of reducing the emission of greenhouse gases (GHGs) and improving the leachate quality during the degradation of the organic solid waste. The leachate quality and the gas composition in each of the reactors were measured during the experimental period (408days). The aeration process entailed the injection of air into plexiglass cylinders (200cm height×10 cm diameter), filled with fresh organic solid waste collected from a composting plant. Different aeration routines were applied, namely, continuous aeration (aerobic reactor A), aeration for three days/week (aerobic-anaerobic reactor B), aeration for 6h/day (aerobic-anaerobic reactor C), and no aeration (non-aerated reactor D). It was found that aerobic reactor A produced the best results in terms of reduction of GHGs and improvement of the leachate quality. The aerobic-anaerobic reactor C was found to be more effective than reactor B in respect of both the emission of GHGs and the leachate quality; moreover, compared with aerobic reactor A, energy costs were reduced by operating this reactor. The transition period phenomenon was investigated during an intensive seven-day experiment conducted on the discharged leachate obtained from aerobic-anaerobic reactors B and C. The experiment concerned the differences in the composition of the gas during the aeration and the non-aeration periods. It was found that the transition period between the aeration and non-aeration cycles, which followed the simultaneous nitrification-denitrification had a considerable effect on the leachate quality of both the reactors. The results indicated that AALM has the potential to reduce

  3. Open lung biopsy

    MedlinePlus

    Biopsy - open lung ... An open lung biopsy is done in the hospital using general anesthesia , which means you are asleep and pain- ... The open lung biopsy is done to evaluate lung problems seen on x-ray or CT scan .

  4. Lung cancer - small cell

    MedlinePlus

    Cancer - lung - small cell; Small cell lung cancer; SCLC ... About 15% of all lung cancer cases are SCLC. Small cell lung cancer is slightly more common in men than women. Almost all cases of SCLC are ...

  5. Tsunami lung.

    PubMed

    Inoue, Yoshihiro; Fujino, Yasuhisa; Onodera, Makoto; Kikuchi, Satoshi; Shozushima, Tatsuyori; Ogino, Nobuyoshi; Mori, Kiyoshi; Oikawa, Hirotaka; Koeda, Yorihiko; Ueda, Hironobu; Takahashi, Tomohiro; Terui, Katsutoshi; Nakadate, Toshihide; Aoki, Hidehiko; Endo, Shigeatsu

    2012-04-01

    We encountered three cases of lung disorders caused by drowning in the recent large tsunami that struck following the Great East Japan Earthquake. All three were females, and two of them were old elderly. All segments of both lungs were involved in all the three patients, necessitating ICU admission and endotracheal intubation and mechanical ventilation. All three died within 3 weeks. In at least two cases, misswallowing of oil was suspected from the features noted at the time of the detection. Sputum culture for bacteria yielded isolation of Stenotrophomonas maltophilia, Legionella pneumophila, Burkholderia cepacia, and Pseudomonas aeruginosa. The cause of tsunami lung may be a combination of chemical induced pneumonia and bacterial pneumonia.

  6. Lipid accumulation and CO2 utilization of Nannochloropsis oculata in response to CO2 aeration.

    PubMed

    Chiu, Sheng-Yi; Kao, Chien-Ya; Tsai, Ming-Ta; Ong, Seow-Chin; Chen, Chiun-Hsun; Lin, Chih-Sheng

    2009-01-01

    In order to produce microalgal lipids that can be transformed to biodiesel fuel, effects of concentration of CO(2) aeration on the biomass production and lipid accumulation of Nannochloropsis oculata in a semicontinuous culture were investigated in this study. Lipid content of N. oculata cells at different growth phases was also explored. The results showed that the lipid accumulation from logarithmic phase to stationary phase of N. oculata NCTU-3 was significantly increased from 30.8% to 50.4%. In the microalgal cultures aerated with 2%, 5%, 10% and 15% CO(2), the maximal biomass and lipid productivity in the semicontinuous system were 0.480 and 0.142 g L(-1)d(-1) with 2% CO(2) aeration, respectively. Even the N. oculata NCTU-3 cultured in the semicontinuous system aerated with 15% CO(2), the biomass and lipid productivity could reach to 0.372 and 0.084 g L(-1)d(-1), respectively. In the comparison of productive efficiencies, the semicontinuous system was operated with two culture approaches over 12d. The biomass and lipid productivity of N. oculata NCTU-3 were 0.497 and 0.151 g L(-1)d(-1) in one-day replacement (half broth was replaced each day), and were 0.296 and 0.121 g L(-1)d(-1) in three-day replacement (three fifth broth was replaced every 3d), respectively. To optimize the condition for long-term biomass and lipid yield from N. oculata NCTU-3, this microalga was suggested to grow in the semicontinuous system aerated with 2% CO(2) and operated by one-day replacement. PMID:18722767

  7. Combination of Methoprene and Controlled Aeration to Manage Insects in Stored Wheat.

    PubMed

    Liu, Samuel S; Arthur, Frank H; VanGundy, Douglas; Phillips, Thomas W

    2016-06-17

    A commercial formulation of the insect growth regulator methoprene was applied to wheat stored in small bins either alone or in combination with controlled aeration of the bins, to lower grain temperature for insect pest management of stored wheat. Grain temperatures were monitored and modified by a computer-controlled thermocouple system that also activated the aeration system at programmed set-points to move cool ambient air through the grain mass to lower grain temperature. Results from sampling insect populations in experimental storage bins along with laboratory mortality bioassays of insects placed on wheat taken from the bins over the course of the storage period showed that methoprene was very effective in controlling infestation by the externally-feeding stored grain insects Plodia interpunctella (Hübner), the Indian meal moth Tribolium castaneum (Herbst), the red flour beetle, Cryptolestes ferrugineus (Stephens), the rusty grain beetle, and also for the internal-feeding pest Rhyzopertha dominica( Fauvel), the lesser grain borer. Methoprene did not give good control of the internal-feeding pest Sitophilus oryzae (L.), the rice weevil. Aeration alone was somewhat effective in suppressing insect population development, while methoprene alone or when combined with aeration greatly enhanced insect control. Commercial grain grading for industry quality standards at the end of the storage period confirmed the impact of insect suppression on maintaining high quality of the stored wheat. This field experiment shows that methoprene combined with aeration to cool grain can be effective for pest management of stored wheat in the southern plains of the United States of America.

  8. [Effect of Aeration Strategies on Emissions of Nitrogenous Gases and Methane During Sludge Bio-Drying].

    PubMed

    Qi, Lu; Wei, Yuan-song; Zhang, Jun-ya; Zhao, Chen-yang; Cai, Xing; Zhang, Yuan-li; Shao, Chun-yan; Li, Hong-mei

    2016-01-15

    The data on nitrogen gas (NH3, N2O, NO) emissions during sludge bio-drying process in China is scarce, especially NO due to its unstable chemical property. In this study, effect of two aeration modes on emissions of methane and nitrogenous gas was compared during the continuous aerated turning pile sludge bio-drying process at full scale. In these two aeration strategies, the one currently used in the plant was set as the control, and the other was set as the test in which the aeration was used for oxygen supply, pile temperature control, and moisture removal in the start-up, middle and final stages, respectively. The results showed that the aeration strategy used in the test could not only obviously accelerate the rate of sludge drying (the moisture contents of the test and the control were 36.6% and 42% on day 11) , but also had a better drying performance (the final moisture contents of the test and the control were 33.6% and 37.6%, respectively) and decreased the ammonia cumulative emission by 5%, (ammonia cumulative emission of the test and the control were 208 mg x m(-3) and 219.8 mg x m(-3), respectively). Though a lower accumulated emission (eCO2) of greenhouse gas in the test at 3.61 kg x t(-1) was observed than that of the control (3.73 kg x t(-1) dry weight) , the cumulative emission of NO in the test at 1.9 g x m(-2) was 15. 9% higher than that of the control (1.6 g x m(-2)).

  9. Combination of Methoprene and Controlled Aeration to Manage Insects in Stored Wheat

    PubMed Central

    Liu, Samuel S.; Arthur, Frank H.; VanGundy, Douglas; Phillips, Thomas W.

    2016-01-01

    A commercial formulation of the insect growth regulator methoprene was applied to wheat stored in small bins either alone or in combination with controlled aeration of the bins, to lower grain temperature for insect pest management of stored wheat. Grain temperatures were monitored and modified by a computer-controlled thermocouple system that also activated the aeration system at programmed set-points to move cool ambient air through the grain mass to lower grain temperature. Results from sampling insect populations in experimental storage bins along with laboratory mortality bioassays of insects placed on wheat taken from the bins over the course of the storage period showed that methoprene was very effective in controlling infestation by the externally-feeding stored grain insects Plodia interpunctella (Hübner), the Indian meal moth Tribolium castaneum (Herbst), the red flour beetle, Cryptolestes ferrugineus (Stephens), the rusty grain beetle, and also for the internal-feeding pest Rhyzopertha dominica( Fauvel), the lesser grain borer. Methoprene did not give good control of the internal-feeding pest Sitophilus oryzae (L.), the rice weevil. Aeration alone was somewhat effective in suppressing insect population development, while methoprene alone or when combined with aeration greatly enhanced insect control. Commercial grain grading for industry quality standards at the end of the storage period confirmed the impact of insect suppression on maintaining high quality of the stored wheat. This field experiment shows that methoprene combined with aeration to cool grain can be effective for pest management of stored wheat in the southern plains of the United States of America. PMID:27322331

  10. Combination of Methoprene and Controlled Aeration to Manage Insects in Stored Wheat.

    PubMed

    Liu, Samuel S; Arthur, Frank H; VanGundy, Douglas; Phillips, Thomas W

    2016-01-01

    A commercial formulation of the insect growth regulator methoprene was applied to wheat stored in small bins either alone or in combination with controlled aeration of the bins, to lower grain temperature for insect pest management of stored wheat. Grain temperatures were monitored and modified by a computer-controlled thermocouple system that also activated the aeration system at programmed set-points to move cool ambient air through the grain mass to lower grain temperature. Results from sampling insect populations in experimental storage bins along with laboratory mortality bioassays of insects placed on wheat taken from the bins over the course of the storage period showed that methoprene was very effective in controlling infestation by the externally-feeding stored grain insects Plodia interpunctella (Hübner), the Indian meal moth Tribolium castaneum (Herbst), the red flour beetle, Cryptolestes ferrugineus (Stephens), the rusty grain beetle, and also for the internal-feeding pest Rhyzopertha dominica( Fauvel), the lesser grain borer. Methoprene did not give good control of the internal-feeding pest Sitophilus oryzae (L.), the rice weevil. Aeration alone was somewhat effective in suppressing insect population development, while methoprene alone or when combined with aeration greatly enhanced insect control. Commercial grain grading for industry quality standards at the end of the storage period confirmed the impact of insect suppression on maintaining high quality of the stored wheat. This field experiment shows that methoprene combined with aeration to cool grain can be effective for pest management of stored wheat in the southern plains of the United States of America. PMID:27322331

  11. Lipid accumulation and CO2 utilization of Nannochloropsis oculata in response to CO2 aeration.

    PubMed

    Chiu, Sheng-Yi; Kao, Chien-Ya; Tsai, Ming-Ta; Ong, Seow-Chin; Chen, Chiun-Hsun; Lin, Chih-Sheng

    2009-01-01

    In order to produce microalgal lipids that can be transformed to biodiesel fuel, effects of concentration of CO(2) aeration on the biomass production and lipid accumulation of Nannochloropsis oculata in a semicontinuous culture were investigated in this study. Lipid content of N. oculata cells at different growth phases was also explored. The results showed that the lipid accumulation from logarithmic phase to stationary phase of N. oculata NCTU-3 was significantly increased from 30.8% to 50.4%. In the microalgal cultures aerated with 2%, 5%, 10% and 15% CO(2), the maximal biomass and lipid productivity in the semicontinuous system were 0.480 and 0.142 g L(-1)d(-1) with 2% CO(2) aeration, respectively. Even the N. oculata NCTU-3 cultured in the semicontinuous system aerated with 15% CO(2), the biomass and lipid productivity could reach to 0.372 and 0.084 g L(-1)d(-1), respectively. In the comparison of productive efficiencies, the semicontinuous system was operated with two culture approaches over 12d. The biomass and lipid productivity of N. oculata NCTU-3 were 0.497 and 0.151 g L(-1)d(-1) in one-day replacement (half broth was replaced each day), and were 0.296 and 0.121 g L(-1)d(-1) in three-day replacement (three fifth broth was replaced every 3d), respectively. To optimize the condition for long-term biomass and lipid yield from N. oculata NCTU-3, this microalga was suggested to grow in the semicontinuous system aerated with 2% CO(2) and operated by one-day replacement.

  12. Sustained lung inflation at birth: what do we know, and what do we need to know?

    PubMed

    McCall, Karen E; Davis, Peter G; Owen, Louise S; Tingay, David G

    2016-03-01

    A sustained inflation has been advocated as a potential method of augmenting lung aeration at birth. Clinical trials have suggested that a sustained inflation may lead to a reduced need for intubation and ventilation in the first few days of life, without cardiovascular compromise or increased lung injury. Despite this, a sustained inflation is not currently a standard of practice, mainly due to a lack of clarity regarding the optimal delivery method. Animal trials have sought to refine delivery techniques. This review will outline current recommendations regarding a sustained inflation, discuss potential strategies for its optimal delivery and suggest priorities for future research.

  13. Intensified organics and nitrogen removal in the intermittent-aerated constructed wetland using a novel sludge-ceramsite as substrate.

    PubMed

    Wu, Haiming; Fan, Jinlin; Zhang, Jian; Ngo, Huu Hao; Guo, Wenshan; Liang, Shuang; Lv, Jialong; Lu, Shaoyong; Wu, Weizhong; Wu, Suqing

    2016-06-01

    In this study, a novel sludge-ceramsite was applied as main substrate in intermittent-aerated subsurface flow constructed wetlands (SSF CWs) for treating decentralized domestic wastewater, and intensified organics and nitrogen removal in different SSF CWs (with and without intermittent aeration, with and without sludge-ceramsite substrate) were evaluated. High removal of 97.2% COD, 98.9% NH4(+)-N and 85.8% TN were obtained simultaneously in the intermittent-aerated CW system using sludge-ceramsite substrate compared with non-aerated CWs. Moreover, results from fluorescence in situ hybridization (FISH) analysis revealed that the growth of ammonia-oxidizing bacteria (AOB) and nitrite-oxidizing bacteria (NOB) in the intermittent-aerated CW system with sludge-ceramsite substrate was enhanced, thus indicating that the application of intermittent aeration and sludge-ceramsite plays an important role in nitrogen transformations. These results suggest that a combination of intermittent aeration and sludge-ceramsite substrate is reliable to enhance the treatment performance in SSF CWs.

  14. Removal of organic pollutants from oak leachate in pilot scale wetland systems: How efficient are aeration and vegetation treatments?

    PubMed

    Svensson, Henric; Ekstam, Börje; Marques, Marcia; Hogland, William

    2015-11-01

    This study investigated the effects of aeration and/or vegetation in experimental constructed wetlands (CWs) as mesocosms on the removal of pollutants in oak wood leachate. Twelve outdoor wetland mesocosms, with randomized replicated treatment combinations of vegetation (Phragmites australis) and aeration was monitored during the second and third year after construction. The investigation included control tanks with no aeration and no vegetation. The parameters monitored were polyphenols (PPs), chemical oxygen demand (COD) and water colour. The reduction of COD after 28 days was approx. 50% and more than 50% of PPs, whereas only 40% of the water colour was removed. Aeration increased the effect of both COD and PP removal. The vegetation treatment had a small but significant effect on removal of COD. The vegetation + aeration treatment, as well as aeration alone, increased the removal efficiency of COD from 9.5 g m(-3) d(-1) in the control to 11 g m(-3) d(-1). The results suggest that CWs can be used to treat stormwater contaminated by oak wood leachate. Further, it is suggested that the main processes for removal of pollutants in the leachate occur in the open-water habitat and that the hydraulic retention time is more important for removal than aeration and vegetation related processes. PMID:26218465

  15. Oxygen demand for the stabilization of the organic fraction of municipal solid waste in passively aerated bioreactors.

    PubMed

    Kasinski, Slawomir; Wojnowska-Baryla, Irena

    2014-02-01

    Conventional aerobic waste treatment technologies require the use of aeration devices that actively transport air through the stabilized waste mass, which greatly increases operating costs. In addition, improperly operated active aeration systems, may have the adverse effect of cooling the stabilized biomass. Because active aeration can be a limiting factor for the stabilization process, passive aeration can be equally effective and less expensive. Unfortunately, there are few reports documenting the use of passive aeration systems in municipal waste stabilization. There have been doubts raised as to whether a passive aeration system provides enough oxygen to the organic matter mineralization processes. In this paper, the effectiveness of aeration during aerobic stabilization of four different organic fractions of municipal waste in a reactor with an integrated passive ventilation system and leachate recirculation was analyzed. For the study, four fractions separated by a rotary screen were chosen. Despite the high temperatures in the reactor, the air flow rate was below 0.016 m(3)/h. Using Darcy's equation, theoretical values of the air flow rate were estimated, depending on the intensity of microbial metabolism and the amount of oxygen required for the oxidation of organic compounds. Calculations showed that the volume of supplied air exceeded the microorganisms demand for oxidation and endogenous activity by 1.7-2.88-fold. PMID:24268917

  16. Removal of organic pollutants from oak leachate in pilot scale wetland systems: How efficient are aeration and vegetation treatments?

    PubMed

    Svensson, Henric; Ekstam, Börje; Marques, Marcia; Hogland, William

    2015-11-01

    This study investigated the effects of aeration and/or vegetation in experimental constructed wetlands (CWs) as mesocosms on the removal of pollutants in oak wood leachate. Twelve outdoor wetland mesocosms, with randomized replicated treatment combinations of vegetation (Phragmites australis) and aeration was monitored during the second and third year after construction. The investigation included control tanks with no aeration and no vegetation. The parameters monitored were polyphenols (PPs), chemical oxygen demand (COD) and water colour. The reduction of COD after 28 days was approx. 50% and more than 50% of PPs, whereas only 40% of the water colour was removed. Aeration increased the effect of both COD and PP removal. The vegetation treatment had a small but significant effect on removal of COD. The vegetation + aeration treatment, as well as aeration alone, increased the removal efficiency of COD from 9.5 g m(-3) d(-1) in the control to 11 g m(-3) d(-1). The results suggest that CWs can be used to treat stormwater contaminated by oak wood leachate. Further, it is suggested that the main processes for removal of pollutants in the leachate occur in the open-water habitat and that the hydraulic retention time is more important for removal than aeration and vegetation related processes.

  17. Influence of aeration modes on leachate characteristic of landfills that adopt the aerobic-anaerobic landfill method.

    PubMed

    Wu, Chuanfu; Shimaoka, Takayuki; Nakayama, Hirofumi; Komiya, Teppei; Chai, Xiaoli; Hao, Yongxia

    2014-01-01

    As far as the optimal design, operation, and field application of the Aerobic-Anaerobic Landfill Method (AALM) are concerned, it is very important to understand how aeration modes (different combinations of aeration depth and air injection rate) affect the biodegradation of organic carbon and the transformation of nitrogen in landfill solid waste. Pilot-scale lysimeter experiments were carried out under different aeration modes to obtain detailed information regarding the influence of aeration modes on leachate characteristics. Results from these lysimeter experiments revealed that aeration at the bottom layer was the most effective for decomposition of organic carbon when compared with aeration at the surface or middle layers. Moreover, the air injection rate led to different nitrogen transformation patterns, unlike the lesser influence it has on organic carbon decomposition. Effective simultaneous nitrification and denitrification were observed for the aeration mode with a higher air injection rate (=1.0 L/min). On the other hand, the phenomenon of sequenced nitrification and denitrification could be observed when a low air injection rate (=0.5L/min.) was employed. Finally, it is concluded that, for AALM, air injection with a higher air injection rate at the deepest layer near the leachate collection pipe tends to accelerate the stabilization of landfill waste as defined in terms of the enhancement of denitrification as well as organic carbon decomposition.

  18. Feasibility study of a passive aeration reactor equipped with vertical pipes for compost stabilization of cow manure.

    PubMed

    Sylla, Youssouf Boundou; Kuroda, Masao; Yamada, Masayuki; Matsumoto, Naoko

    2006-10-01

    Pilot-scale composting was carried out with cow manure to evaluate the performances of two passive aeration systems: a conventional passive aeration system equipped with horizontal pipes and an unusual passive aeration method based on air delivery by means of vertical pipes. The effects of both types of passive aeration apparatus were investigated in order to determine the degree of composting rate by continuously monitoring temperature, moisture content, organic matter, electrical conductivity, pH and C/N ratio in the piles. Temperatures in the range of thermophily (55-65 degrees C) were reached in all runs within 1-2 days then lasting for about 1 week, a span long enough for pathogen abatement. Results suggest that passive aeration carried out by vertical pipes is more effective for air delivery into compost piles than conventional passive aeration of air adduction with horizontal pipes. The variation in the number of vertical pipes was revealed to be an important parameter for the control of composting rate and temperature. Composting rates estimated from the heat balance equation were substantially in agreement with those computed through the conversion ratio of total organic matter decrement. The conversion ratios and composting rates obtained in this study using passive aeration with vertical pipes were well aligned with those found using forced air delivery systems.

  19. Feasibility study of a passive aeration reactor equipped with vertical pipes for compost stabilization of cow manure.

    PubMed

    Sylla, Youssouf Boundou; Kuroda, Masao; Yamada, Masayuki; Matsumoto, Naoko

    2006-10-01

    Pilot-scale composting was carried out with cow manure to evaluate the performances of two passive aeration systems: a conventional passive aeration system equipped with horizontal pipes and an unusual passive aeration method based on air delivery by means of vertical pipes. The effects of both types of passive aeration apparatus were investigated in order to determine the degree of composting rate by continuously monitoring temperature, moisture content, organic matter, electrical conductivity, pH and C/N ratio in the piles. Temperatures in the range of thermophily (55-65 degrees C) were reached in all runs within 1-2 days then lasting for about 1 week, a span long enough for pathogen abatement. Results suggest that passive aeration carried out by vertical pipes is more effective for air delivery into compost piles than conventional passive aeration of air adduction with horizontal pipes. The variation in the number of vertical pipes was revealed to be an important parameter for the control of composting rate and temperature. Composting rates estimated from the heat balance equation were substantially in agreement with those computed through the conversion ratio of total organic matter decrement. The conversion ratios and composting rates obtained in this study using passive aeration with vertical pipes were well aligned with those found using forced air delivery systems. PMID:17121117

  20. Oxygen demand for the stabilization of the organic fraction of municipal solid waste in passively aerated bioreactors

    SciTech Connect

    Kasinski, Slawomir Wojnowska-Baryla, Irena

    2014-02-15

    Highlights: • The use of an passively aerated reactor enables effective stabilization of OFMSW. • Convective air flow does not inhibit the aerobic stabilization of waste. • The use of an passively aerated reactor reduces the heat loss due to convection. • The volume of supplied air exceeds 1.7–2.88 times the microorganisms demand. - Abstract: Conventional aerobic waste treatment technologies require the use of aeration devices that actively transport air through the stabilized waste mass, which greatly increases operating costs. In addition, improperly operated active aeration systems, may have the adverse effect of cooling the stabilized biomass. Because active aeration can be a limiting factor for the stabilization process, passive aeration can be equally effective and less expensive. Unfortunately, there are few reports documenting the use of passive aeration systems in municipal waste stabilization. There have been doubts raised as to whether a passive aeration system provides enough oxygen to the organic matter mineralization processes. In this paper, the effectiveness of aeration during aerobic stabilization of four different organic fractions of municipal waste in a reactor with an integrated passive ventilation system and leachate recirculation was analyzed. For the study, four fractions separated by a rotary screen were chosen. Despite the high temperatures in the reactor, the air flow rate was below 0.016 m{sup 3}/h. Using Darcy’s equation, theoretical values of the air flow rate were estimated, depending on the intensity of microbial metabolism and the amount of oxygen required for the oxidation of organic compounds. Calculations showed that the volume of supplied air exceeded the microorganisms demand for oxidation and endogenous activity by 1.7–2.88-fold.

  1. Optimization of nitrogen removal for alternating intermittent aeration-type activated sludge system: a new process modification.

    PubMed

    Insel, Guclu; Sözen, Seval; Başak, Serden; Orhon, Derin

    2006-01-01

    A new activated sludge process modification was proposed for intermittent aeration process to achieve more stable nitrogen removal performance. A single completely mixed reactor was divided into two compartments in series and operated in intermittent aeration mode by using activated sludge simulation model. The new configuration provided competetive advantage on nitrification as well as denitrification capacity, compared to the intermittently aerated system with a single reactor. In addition, the dissolved oxygen set-point control during air-on periods was found to be an important parameter in terms of nitrogen removal.

  2. Structure formation of aerated concrete containing waste coal combustion products generated in the thermal vortex power units

    NASA Astrophysics Data System (ADS)

    Ivanov, A. I.; Stolboushkin, A. Yu; Temlyanstev, M. V.; Syromyasov, V. A.; Fomina, O. A.

    2016-10-01

    The results of fly ash research, generated in the process of waste coal combustion in the thermal vortex power units and used as an aggregate in aerated concrete, are provided. It is established that fly ash can be used in the production of cement or concrete with low loss on ignition (LOI). The permitted value of LOI in fly ash, affecting the structure formation and operational properties of aerated concrete, are defined. During non-autoclaved hardening of aerated concrete with fly ash aggregate and LOI not higher than 2%, the formation of acicular crystals of ettringite, reinforcing interporous partitions, takes place.

  3. The Spatiotemporal Cellular Dynamics of Lung Immunity

    PubMed Central

    Lelkes, E.; Headley, M.B.; Thornton, E.E.; Looney, M.R.; Krummel, M.F.

    2014-01-01

    The lung is a complex structure that is interdigitated with immune cells. Understanding the 4-dimensional process of normal and defective lung function and immunity has been a centuries-old problem. Challenges intrinsic to the lung have limited adequate microscopic evaluation of its cellular dynamics in real time, until recently. Because of emerging technologies, we now recognize alveolar-to-airway transport of inhaled antigen. We understand the nature of neutrophil entry during lung injury and are learning more about cellular interactions during inflammatory states. Insights are also accumulating in lung development and the metatastatic niche of the lung. Here we assess the developing technology of lung imaging, its merits for studies of pathophysiology and areas where further advances are needed. PMID:24974157

  4. Optimized aeration strategies for nitrogen and phosphorus removal with aerobic granular sludge.

    PubMed

    Lochmatter, Samuel; Gonzalez-Gil, Graciela; Holliger, Christof

    2013-10-15

    Biological wastewater treatment by aerobic granular sludge biofilms offers the possibility to combine carbon (COD), nitrogen (N) and phosphorus (P) removal in a single reactor. Since denitrification can be affected by suboptimal dissolved oxygen concentrations (DO) and limited availability of COD, different aeration strategies and COD loads were tested to improve N- and P-removal in granular sludge systems. Aeration strategies promoting alternating nitrification and denitrification (AND) were studied to improve reactor efficiencies in comparison with more classical simultaneous nitrification-denitrification (SND) strategies. With nutrient loading rates of 1.6 gCOD L(-1) d(-1), 0.2 gN L(-1) d(-1), and 0.08 gP L(-1) d(-1), and SND aeration strategies, N-removal was limited to 62.3 ± 3.4%. Higher COD loads markedly improved N-removal showing that denitrification was limited by COD. AND strategies were more efficient than SND strategies. Alternating high and low DO phases during the aeration phase increased N-removal to 71.2 ± 5.6% with a COD loading rate of 1.6 gCOD L(-1) d(-1). Periods of low DO were presumably favorable to denitrifying P-removal saving COD necessary for heterotrophic N-removal. Intermittent aeration with anoxic periods without mixing between the aeration pulses was even more favorable to N-removal, resulting in 78.3 ± 2.9% N-removal with the lowest COD loading rate tested. P-removal was under all tested conditions between 88 and 98%, and was negatively correlated with the concentration of nitrite and nitrate in the effluent (r = -0.74, p < 0.01). With low COD loading rates, important emissions of undesired N2O gas were observed and a total of 7-9% of N left the reactor as N2O. However, N2O emissions significantly decreased with higher COD loads under AND conditions.

  5. Ammonia-based intermittent aeration control optimized for efficient nitrogen removal.

    PubMed

    Regmi, Pusker; Bunce, Ryder; Miller, Mark W; Park, Hongkeun; Chandran, Kartik; Wett, Bernhard; Murthy, Sudhir; Bott, Charles B

    2015-10-01

    This work describes the development of an intermittently aerated pilot-scale process (V = 0.45 m(3) ) operated for optimized efficient nitrogen removal in terms of volume, supplemental carbon and alkalinity requirements. The intermittent aeration pattern was controlled using a strategy based on effluent ammonia concentration set-points. The unique feature of the ammonia-based aeration control was that a fixed dissolved oxygen (DO) set-point was used and the length of the aerobic and anoxic time (anoxic time ≥25% of total cycle time) were changed based on the effluent ammonia concentration. Unlike continuously aerated ammonia-based aeration control strategies, this approach offered control over the aerobic solids retention time (SRT) to deal with fluctuating ammonia loading without solely relying on changes to the total SRT. This approach allowed the system to be operated at a total SRT with a small safety factor. The benefits of operating at an aggressive SRT were reduced hydraulic retention time (HRT) for nitrogen removal. As a result of such an operation, nitrite oxidizing bacteria (NOB) out-selection was also obtained (ammonia oxidizing bacteria [AOB] maximum activity: 400 ± 79 mgN/L/d, NOB maximum activity: 257 ± 133 mgN/L/d, P < 0.001) expanding opportunities for short-cut nitrogen removal. The pilot demonstrated a total inorganic nitrogen (TIN) removal rate of 95 ± 30 mgN/L/d at an influent chemical oxygen demand: ammonia (COD/NH4 (+) -N) ratio of 10.2 ± 2.2 at 25°C within the hydraulic retention time (HRT) of 4 h and within a total SRT of 5-10 days. The TIN removal efficiency up to 91% was observed during the study, while effluent TIN was 9.6 ± 4.4 mgN/L. Therefore, this pilot-scale study demonstrates that application of the proposed on-line aeration control is capable of relatively high nitrogen removal without supplemental carbon and alkalinity addition at a low HRT.

  6. Comparison of aeration and spinosad for suppressing insects in stored wheat.

    PubMed

    Flinn, P W; Subramanyam, Bh; Arthur, F H

    2004-08-01

    Field studies were conducted from July 2002 to January 2003 for evaluating the effects of controlled aeration and a commercial biological insecticide, spinosad, in suppressing insect populations in stored wheat. Six cylindrical steel bins were filled with newly harvested (2002 crop year) hard red winter wheat on 9 and 10 July 2002. Each bin contained 30.7 metric tons (1,100 bu) of wheat. Wheat in two bins was left untreated (control), whereas wheat in two bins was treated with spinosad, and in another two bins was subjected to aeration by using aeration controllers. Spinosad was applied to wheat at the time of bin filling to obtain a rate of 1 mg ([AI])/kg. Aeration controllers were set to run the fans when ambient air temperature fell below 23.9, 18.3, and 7.2 degrees C for the first, second, and third cooling cycles, respectively. We added 400 adults each of the rusty grain beetle, Cryptolestes ferrugineus (Stephens); lesser grain borer, Rhyzopertha dominica (F.); and red flour beetle, Tribolium castaneum (Herbst), to the grain at monthly intervals between July and October 2002. Insect density in the bins was estimated monthly by taking 3-kg grain samples from 21 locations within each bin by using a pneumatic grain sampler. No live T. castaneum or C. ferrugineus and very low densities of R. dominica (<0.008 adults per kilogram) were found in wheat treated with spinosad during the 6-mo sampling period. Density of C. ferrugineus and T. castaneum in aerated bins did not exceed two adults per kilogram (the Federal Grain Inspection Service standard for infested wheat), whereas R. dominica increased to 12 adults per kilogram in November 2002, which subsequently decreased to three adults per kilogram in January 2003. In the untreated (control) bins, R. dominica density increased faster than that of C. ferrugineus or T. castaneum. Density of R. dominica peaked at 58 adults per kilogram in October 2002 and decreased subsequently, whereas T. castaneum density was 10 adults

  7. QUANTITATIVE CT ANALYSIS, AIRFLOW OBSTRUCTION AND LUNG CANCER IN THE PITTSBURGH LUNG SCREENING STUDY

    PubMed Central

    Wilson, David O; Leader, Joseph K; Fuhrman, Carl R; Reilly, John J; Sciurba, Frank C.; Weissfeld, Joel L

    2011-01-01

    Background To study the relationship between emphysema, airflow obstruction and lung cancer in a high risk population we performed quantitative analysis of screening computed tomography (CT) scans. Methods Subjects completed questionnaires, spirometry and low-dose helical chest CT. Analyses compared cases and controls according to automated quantitative analysis of lung parenchyma and airways measures. Results Our case-control study of 117 matched pairs of lung cancer cases and controls did not reveal any airway or lung parenchymal findings on quantitative analysis of screening CT scans that were associated with increased lung cancer risk. Airway measures including wall area %, lumen perimeter, lumen area and average wall HU, and parenchymal measures including lung fraction < −910 Hounsfield Units (HU), were not statistically different between cases and controls. Conclusions The relationship between visual assessment of emphysema and increased lung cancer risk could not be verified by quantitative analysis of low-dose screening CT scans in a high risk tobacco exposed population. PMID:21610523

  8. Physicochemical properties and ability to generate free radicals of ambient coarse, fine, and ultrafine particles in the atmosphere of Xuanwei, China, an area of high lung cancer incidence

    NASA Astrophysics Data System (ADS)

    Lu, Senlin; Yi, Fei; Hao, Xiaojie; Yu, Shang; Ren, Jingjing; Wu, Minghong; Jialiang, Feng; Yonemochi, Shinich; Wang, Qingyue

    2014-11-01

    The link between the high incidence of lung cancer and harmful pollutants emitted by local coal combustion in Xuanwei, Yunnan province, China, has been a focus of study since the 1980s. However, the mechanisms responsible for the high lung cancer rate remain unclear, necessitating further study. Since a close relationship between ambient air particle pollution and respiratory diseases exists, we sampled size-resolved ambient particles from the atmosphere of Xuanwei. In our indoor experiment, cutting-edge methods, including scanning electron microscopy coupled with energy dispersive X-ray detection (SEM/EDX), particle-induced X-ray emission (PIXE), electronic paramagnetic resonance (EPR) and the cell-free DCFH-DA assay, were employed to investigate the physicochemical properties, the potential to generate free radicals and the oxidative potential of ambient coarse (diameter, 1.8-10 μm), fine (diameter, 0.1-1.8 μm), and ultrafine (diameter, <0.1 μm) particles. We found the total mass concentrations of the size-resolved particles collected in spring were higher than that in early winter. Mass percentage of fine particles accounted for 68% and 61% of the total particulate mass in spring and in early winter samples, respectively, indicating that fine particles were the major component of the Xuanwei ambient particulate matters. On the other hand, the results of SEM/EDX analysis showed that the coarse particles were dominated by minerals, the fine particles by soot aggregates and fly ashes, and the ultrafine particles by soot particles and unidentified particles. Our PIXE results revealed that crustal elements (Ca, Ti Si, Fe) were mainly distributed in coarse particles, while trace metals (Cr, Mn, Ni, Cu, Zn, Pb) dominated in the fine particle fraction, and S, a typical element emitted by coal combustion, mainly resided in fine particles collected from the winter atmosphere. EPR results indicated that the magnitude of free radical intensity caused by size

  9. Modeling the nuclear magnetic resonance behavior of lung: from electrical engineering to critical care medicine.

    PubMed

    Cutillo, A G; Ailion, D C

    1999-01-01

    The present article reviews the basic principles of a new approach to the characterization of pulmonary disease. This approach is based on the unique nuclear magnetic resonance (NMR) properties of the lung and combines experimental measurements (using specially developed NMR techniques) with theoretical simulations. The NMR signal from inflated lungs decays very rapidly compared with the signal from completely collapsed (airless) lungs. This phenomenon is due to the presence of internal magnetic field inhomogeneity produced by the alveolar air-tissue interface (because air and water have different magnetic susceptibilities). The air-tissue interface effects can be detected and quantified by magnetic resonance imaging (MRI) techniques using temporally symmetric and asymmetric spin-echo sequences. Theoretical models developed to explain the internal (tissue-induced) magnetic field inhomogeneity in aerated lungs predict the NMR lung behavior as a function of various technical and physiological factors (e.g., the level of lung inflation) and simulate the effects of various lung disorders (in particular, pulmonary edema) on this behavior. Good agreement has been observed between the predictions obtained from the mathematical models and the results of experimental NMR measurements in normal and diseased lungs. Our theoretical and experimental data have important pathophysiological and clinical implications, especially with respect to the characterization of acute lung disease (e.g., pulmonary edema) and the management of critically ill patients.

  10. Effects of aeration rate on degradation process of oil palm empty fruit bunch with kinetic-dynamic modeling.

    PubMed

    Talib, Ahmad Tarmezee; Mokhtar, Mohd Noriznan; Baharuddin, Azhari Samsu; Sulaiman, Alawi

    2014-10-01

    The effect of different aeration rates on the organic matter (OM) degradation during the active phase of oil palm empty fruit bunch (EFB)-rabbit manure co-composting process under constant forced-aeration system has been studied. Four different aeration rates, 0.13 L min(-1) kg(DM)(-1),0.26 L min(-1) kg(DM)(-1),0.49 L min(-1) kg(DM)(-1) and 0.74 L min(-1) kg(DM)(-1) were applied. 0.26 L min(-1) kg(DM)(-1) provided enough oxygen level (10%) for the rest of composting period, showing 40.5% of OM reduction that is better than other aeration rates. A dynamic mathematical model describing OM degradation, based on the ratio between OM content and initial OM content with correction functions of moisture content, free air space, oxygen and temperature has been proposed.

  11. Effects of soil aeration, legume residue, and soil texture on transformations of macro- and micronutrients in soils. [Vicia villosa

    SciTech Connect

    Walters, D.T.; Doran, J.W. ); Aulakh, M.S. )

    1992-02-01

    Soil aeration is an important factor controlling microbial activity, nutrient availability, and plant root growth. The authors investigated the effect of hairy vetch (Vicia villosa) addition to well aerated (60% water-filled pore space (WFPS)) and poorly aerated (90% WFPS) soils of varying texture on transformations of C, N, P, K, Ca, Mg, S, Zn, Mn, Fe, and Cu for a 30-d period. The results of this study imply that incorporation of easily decomposable residue may supply substantial amounts of nutrients to growing plants. Where soils remain wet for > 10 d, residues may create intensive reducing conditions and a several fold increase in available Fe, Mn, Cu, and P. Conversely, DTPA extractable Fe, Mn, and Cu can vary greatly within a few weeks depending on soil aeration status, residue management, time of sampling, and soil texture and may lead to erroneous indices of nutrient availability to plants.

  12. Effects of aeration rate on degradation process of oil palm empty fruit bunch with kinetic-dynamic modeling.

    PubMed

    Talib, Ahmad Tarmezee; Mokhtar, Mohd Noriznan; Baharuddin, Azhari Samsu; Sulaiman, Alawi

    2014-10-01

    The effect of different aeration rates on the organic matter (OM) degradation during the active phase of oil palm empty fruit bunch (EFB)-rabbit manure co-composting process under constant forced-aeration system has been studied. Four different aeration rates, 0.13 L min(-1) kg(DM)(-1),0.26 L min(-1) kg(DM)(-1),0.49 L min(-1) kg(DM)(-1) and 0.74 L min(-1) kg(DM)(-1) were applied. 0.26 L min(-1) kg(DM)(-1) provided enough oxygen level (10%) for the rest of composting period, showing 40.5% of OM reduction that is better than other aeration rates. A dynamic mathematical model describing OM degradation, based on the ratio between OM content and initial OM content with correction functions of moisture content, free air space, oxygen and temperature has been proposed. PMID:25079208

  13. Design of passively aerated compost piles: Vertical air velocities between the pipes

    SciTech Connect

    Lynch, N.J.; Cherry, R.S.

    1996-09-01

    Passively aerated compost piles are built on a base of porous materials, such as straw or wood chips, in which perforated air supply pipes are distributed. The piles are not turned during composting, nor is forced-aeration equipment used, which significantly reduces the operating and capital expenses associated with these piles. Currently, pile configurations and materials are worked out by trial and error. Fundamentally based design procedures are difficult to develop because the natural convection air flow rate is not explicitly known, but rather is closely coupled with the pile temperature. This paper develops a mathematical model to analytically determine the maximum upward air flow velocity over an air supply pipe and the drop in vertical velocity away from the pipe. This model has one dimensionless number, dependent on the pile and base properties, which fully characterizes the velocity profile between the pipes. 9 refs., 4 figs., 1 tab.

  14. Relationship between respiratory quotient, nitrification, and nitrous oxide emissions in a forced aerated composting process.

    PubMed

    Tsutsui, Hirofumi; Fujiwara, Taku; Inoue, Daisuke; Ito, Ryusei; Matsukawa, Kazutsugu; Funamizu, Naoyuki

    2015-08-01

    We assessed the relationship between respiratory quotient (RQ) and nitrification and nitrous oxide (N2O) emission in forced aerated composting using lab-scale reactors. Relatively high RQ values from degradation of readily degradable organics initially occurred. RQ then stabilized at slightly lower values, then decreased. Continuous emission of N2O was observed during the RQ decrease. Correlation between nitrification and N2O emission shows that the latter was triggered by nitrification. Mass balances demonstrated that the O2 consumption of nitrification (∼24.8mmol) was slightly higher than that of CO2 emission (∼20.0mmol), indicating that the RQ decrease was caused by the occurrence of nitrification. Results indicate that RQ is a useful index, which not only reflects the bioavailability of organics but also predicts the occurrence of nitrification and N2O emission in forced aerated composting. PMID:25987285

  15. Binary Effect of Fly Ash and Palm Oil Fuel Ash on Heat of Hydration Aerated Concrete

    PubMed Central

    Mehmannavaz, Taha; Ismail, Mohammad; Radin Sumadi, Salihuddin; Rafique Bhutta, Muhammad Aamer; Samadi, Mostafa

    2014-01-01

    The binary effect of pulverized fuel ash (PFA) and palm oil fuel ash (POFA) on heat of hydration of aerated concrete was studied. Three aerated concrete mixes were prepared, namely, concrete containing 100% ordinary Portland cement (control sample or Type I), binary concrete made from 50% POFA (Type II), and ternary concrete containing 30% POFA and 20% PFA (Type III). It is found that the temperature increases due to heat of hydration through all the concrete specimens especially in the control sample. However, the total temperature rises caused by the heat of hydration through both of the new binary and ternary concrete were significantly lower than the control sample. The obtained results reveal that the replacement of Portland cement with binary and ternary materials is beneficial, particularly for mass concrete where thermal cracking due to extreme heat rise is of great concern. PMID:24696646

  16. Enhanced solid waste stabilization in aerobic landfills using low aeration rates and high density compaction.

    PubMed

    El Fadel, Mutasem; Fayad, Wissam; Hashisho, Jihan

    2013-01-01

    Historically, municipal solid waste landfills have been designed and operated as storage facilities with suboptimal degradation under anaerobic conditions resulting in slow waste stabilization, gaseous emissions and leachate formation. This article examines the aerobic bioreactor alternative combining the recirculation of high strength leachate [chemical oxygen demand (COD): 89,000-95,600 mg/l; biological oxygen demand (BOD): 75,700-80,000 mg/l)] with low aeration rates (0.0125-0.05 l/min.kg) at high initial waste compaction (657-875 kg/m3) to promote and control biodegradation of solid waste in laboratory-scale columns (diameter = 60 cm, height = 1 m). Low aeration rates coupled with high initial density demonstrated improved performance with increased levels of stabilization with COD and BOD attenuation reaching up to 96%, final C:N ratio of 25 and waste settlement up to 55%. PMID:22878935

  17. Optimization of Energy Consumption and Mass Transfer Parameters in a Surface Aeration Vessel.

    PubMed

    Mohammadpour, A; AkhavanBehabadi, M A; Ebrahimzadeh, M; Raisee, M; MajdiNasab, A R; Nosrati, M; Mousavi, S M

    2016-04-01

    This paper reports tests on a lab-scale surface aeration vessel was equipped with a Rushton turbine to examine its performance in terms of standard aeration efficiency (SAE), mixing time, and void fraction characteristics. These characteristics were investigated by tests using variations of rotor speed, impeller immersion depth, and water level. Results showed that variation of impeller immersion depth had a greater effect on the SAE compared to variation of water level. Moreover, the SAE increased with rotor speeds up to about 150 to 200 rpm and then decreased. In addition, void fraction improved by impeller immersion depth and rotor speed enhancement; however, mixing time and power number were reduced as rotor speed increased. According to the response surface methodology statistical optimizations, optimum values for rotor speed, impeller immersion depth, and water level were 168.90 rpm, 25 mm, and 30 cm, respectively, to achieve the maximum value of SAE.

  18. Treatment of dilute waste oil emulsion from aluminum rolling mill operations by a biological aerated filter

    SciTech Connect

    Carriere, P.E.; Reed, B.E.; Brooks, J.

    1995-12-31

    Wastewater from aluminum industry contains oil used primarily during the aluminum rolling process. In this study, oily wastewater from the manufacturer`s processes was transferred to two holding ponds having a total capacity of about 5 million gallons. A detention time of 10 days was maintained to allow the free oil to rise to the surface and the solids to settle. Wastewater from the ponds was withdrawn at a depth of 9 feet and used as influent to the pilot-scale biological aerated filter. The main objective of this study was to evaluate the performance of the pilot-scale biological aerated filter on oil and grease (O and G) and total suspended solids (TSS) removal.

  19. Binary effect of fly ash and palm oil fuel ash on heat of hydration aerated concrete.

    PubMed

    Mehmannavaz, Taha; Ismail, Mohammad; Radin Sumadi, Salihuddin; Rafique Bhutta, Muhammad Aamer; Samadi, Mostafa; Sajjadi, Seyed Mahdi

    2014-01-01

    The binary effect of pulverized fuel ash (PFA) and palm oil fuel ash (POFA) on heat of hydration of aerated concrete was studied. Three aerated concrete mixes were prepared, namely, concrete containing 100% ordinary Portland cement (control sample or Type I), binary concrete made from 50% POFA (Type II), and ternary concrete containing 30% POFA and 20% PFA (Type III). It is found that the temperature increases due to heat of hydration through all the concrete specimens especially in the control sample. However, the total temperature rises caused by the heat of hydration through both of the new binary and ternary concrete were significantly lower than the control sample. The obtained results reveal that the replacement of Portland cement with binary and ternary materials is beneficial, particularly for mass concrete where thermal cracking due to extreme heat rise is of great concern.

  20. Binary effect of fly ash and palm oil fuel ash on heat of hydration aerated concrete.

    PubMed

    Mehmannavaz, Taha; Ismail, Mohammad; Radin Sumadi, Salihuddin; Rafique Bhutta, Muhammad Aamer; Samadi, Mostafa; Sajjadi, Seyed Mahdi

    2014-01-01

    The binary effect of pulverized fuel ash (PFA) and palm oil fuel ash (POFA) on heat of hydration of aerated concrete was studied. Three aerated concrete mixes were prepared, namely, concrete containing 100% ordinary Portland cement (control sample or Type I), binary concrete made from 50% POFA (Type II), and ternary concrete containing 30% POFA and 20% PFA (Type III). It is found that the temperature increases due to heat of hydration through all the concrete specimens especially in the control sample. However, the total temperature rises caused by the heat of hydration through both of the new binary and ternary concrete were significantly lower than the control sample. The obtained results reveal that the replacement of Portland cement with binary and ternary materials is beneficial, particularly for mass concrete where thermal cracking due to extreme heat rise is of great concern. PMID:24696646

  1. Optimization of Energy Consumption and Mass Transfer Parameters in a Surface Aeration Vessel.

    PubMed

    Mohammadpour, A; AkhavanBehabadi, M A; Ebrahimzadeh, M; Raisee, M; MajdiNasab, A R; Nosrati, M; Mousavi, S M

    2016-04-01

    This paper reports tests on a lab-scale surface aeration vessel was equipped with a Rushton turbine to examine its performance in terms of standard aeration efficiency (SAE), mixing time, and void fraction characteristics. These characteristics were investigated by tests using variations of rotor speed, impeller immersion depth, and water level. Results showed that variation of impeller immersion depth had a greater effect on the SAE compared to variation of water level. Moreover, the SAE increased with rotor speeds up to about 150 to 200 rpm and then decreased. In addition, void fraction improved by impeller immersion depth and rotor speed enhancement; however, mixing time and power number were reduced as rotor speed increased. According to the response surface methodology statistical optimizations, optimum values for rotor speed, impeller immersion depth, and water level were 168.90 rpm, 25 mm, and 30 cm, respectively, to achieve the maximum value of SAE. PMID:27131059

  2. Optimization of micro-aeration intensity in acidogenic reactor of a two-phase anaerobic digester treating food waste.

    PubMed

    Xu, Suyun; Selvam, Ammaiyappan; Wong, Jonathan W C

    2014-02-01

    Micro-aeration is known to promote the activities of hydrolytic exo-enzymes and used as a strategy to improve the hydrolysis of particulate substrate. The effect of different micro-aeration rates, 0, 129, 258, and 387 L-air/kg TS/d (denoted as LBR-AN, LBR-6h, LBR-3h and LBR-2h, respectively) on the solubilization of food waste was evaluated at 35°C in four leach bed reactors (LBR) coupled with methanogenic upflow anaerobic sludge blanket (UASB) reactor. Results indicate that the intensity of micro-aeration influenced the hydrolysis and methane yield. Adequate micro-aeration intensity in LBR-3h and LBR-2h significantly enhanced the carbohydrate and protein hydrolysis by 21-27% and 38-64% respectively. Due to the accelerated acidogenesis, more than 3-fold of acetic acid and butyric acid were produced in LBR-3h as compared to the anaerobic treatment LBR-AN resulting in the maximum methane yield of 0.27 L CH4/g VS(added) in the UASB. The performance of LBR-6h with inadequate aeration was similar to that of LBR-AN with a comparable hydrolysis degree. Nevertheless, higher aeration intensity in LBR-2h was also unfavorable for methane yield due to significant biomass generation and CO2 respiration of up to 18.5% and 32.8% of the total soluble hydrolysate, respectively. To conclude, appropriate micro-aeration rate can promote the hydrolysis of solid organic waste and methane yield without undesirable carbon loss and an aeration intensity of 258 L-air/kg TS/d is recommended for acidogenic LBR treating food waste.

  3. Turbine Aeration Design Software for Mitigating Adverse Environmental Impacts Resulting From Conventional Hydropower Turbines

    SciTech Connect

    Gulliver, John S.

    2015-03-01

    Conventional hydropower turbine aeration test-bed for computational routines and software tools for improving environmental mitigation technologies for conventional hydropower systems. In achieving this goal, we have partnered with Alstom, a global leader in energy technology development and United States power generation, with additional funding from the Initiative for Renewable Energy and the Environment (IREE) and the College of Science and Engineering (CSE) at the UMN

  4. Field trial of a new aeration system for enhancing biodegradation in a biopile.

    PubMed

    Li, L; Cunningham, C J; Pas, Valerie; Philp, J C; Barry, D A; Anderson, P

    2004-01-01

    The influence of a new aeration system on the biopile performance was investigated. The purpose was to increase biodegradation efficiency by optimising airflow through the pile. During a 1-month field trial, the performance of a new system using two perforated vertical pipes with wind-driven turbines was compared with that of a standard pile configuration with two horizontal perforated pipes. Both piles were composed of a similar mix of diesel-contaminated soils, woodchips, compost and NPK fertiliser. Hydrocarbons were recovered using solvent extraction, and determined both gravimetrically and by gas chromatography. Total heterotrophs, pH and moisture content were also assessed. Air pressure measurements were made to compare the efficiency of suction in the pipes. Results at the end of the experiment showed that there was no significant difference between the two piles in the total amount of hydrocarbon biodegradation. The normalised degradation rate was, however, considerably higher in the new system than in the standard one, suggesting that the vertical venting method may have improved the efficiency of the biological reactions in the pile. The pressure measurements showed a significant improvement in the suction produced by the new aeration system. However, many factors other than the airflow (oxygen supply) may influence and limit the biodegradation rates, including moisture content, age of contaminants and the climatic conditions. Additional experiments and modelling need to be carried out to explore further the new aeration method and to develop criteria and guidelines for engineering design of optimal aeration schemes in order to achieve maximum biodegradation in biopiles. PMID:14761751

  5. Field trial of a new aeration system for enhancing biodegradation in a biopile.

    PubMed

    Li, L; Cunningham, C J; Pas, Valerie; Philp, J C; Barry, D A; Anderson, P

    2004-01-01

    The influence of a new aeration system on the biopile performance was investigated. The purpose was to increase biodegradation efficiency by optimising airflow through the pile. During a 1-month field trial, the performance of a new system using two perforated vertical pipes with wind-driven turbines was compared with that of a standard pile configuration with two horizontal perforated pipes. Both piles were composed of a similar mix of diesel-contaminated soils, woodchips, compost and NPK fertiliser. Hydrocarbons were recovered using solvent extraction, and determined both gravimetrically and by gas chromatography. Total heterotrophs, pH and moisture content were also assessed. Air pressure measurements were made to compare the efficiency of suction in the pipes. Results at the end of the experiment showed that there was no significant difference between the two piles in the total amount of hydrocarbon biodegradation. The normalised degradation rate was, however, considerably higher in the new system than in the standard one, suggesting that the vertical venting method may have improved the efficiency of the biological reactions in the pile. The pressure measurements showed a significant improvement in the suction produced by the new aeration system. However, many factors other than the airflow (oxygen supply) may influence and limit the biodegradation rates, including moisture content, age of contaminants and the climatic conditions. Additional experiments and modelling need to be carried out to explore further the new aeration method and to develop criteria and guidelines for engineering design of optimal aeration schemes in order to achieve maximum biodegradation in biopiles.

  6. Nitrogen Removal over Nitrite by Aeration Control in Aerobic Granular Sludge Sequencing Batch Reactors

    PubMed Central

    Lochmatter, Samuel; Maillard, Julien; Holliger, Christof

    2014-01-01

    This study investigated the potential of aeration control for the achievement of N-removal over nitrite with aerobic granular sludge in sequencing batch reactors. N-removal over nitrite requires less COD, which is particularly interesting if COD is the limiting parameter for nutrient removal. The nutrient removal performances for COD, N and P have been analyzed as well as the concentration of nitrite-oxidizing bacteria in the granular sludge. Aeration phase length control combined with intermittent aeration or alternate high-low DO, has proven to be an efficient way to reduce the nitrite-oxidizing bacteria population and hence achieve N-removal over nitrite. N-removal efficiencies of up to 95% were achieved for an influent wastewater with COD:N:P ratios of 20:2.5:1. The total N-removal rate was 0.18 kgN·m−3·d−1. With N-removal over nitrate the N-removal was only 74%. At 20 °C, the nitrite-oxidizing bacteria concentration decreased by over 95% in 60 days and it was possible to switch from N-removal over nitrite to N-removal over nitrate and back again. At 15 °C, the nitrite-oxidizing bacteria concentration decreased too but less, and nitrite oxidation could not be completely suppressed. However, the combination of aeration phase length control and high-low DO was also at 15 °C successful to maintain the nitrite pathway despite the fact that the maximum growth rate of nitrite-oxidizing bacteria at temperatures below 20 °C is in general higher than the one of ammonium-oxidizing bacteria. PMID:25006970

  7. Mesocosm-scale evaluation of faunal and microbial communities of aerated and unaerated leachfield soil.

    PubMed

    Amador, José A; Potts, David A; Savin, Mary C; Tomlinson, Peter; Görres, Josef H; Nicosia, Erika L

    2006-01-01

    Aeration improves the capacity of leachfields to decontaminate and reduce the nutrient load of wastewater. To gain a better understanding of the effects of aeration, we examined the faunal and microbial communities of septic system leachfield soil (0-4 and 4-13 cm) using replicated (n = 3) mesocosms that were actively aerated (AIR) or unaerated (LEACH). Protozoa were 40 to 140 times more abundant in AIR than in LEACH soil. No nematodes were found in LEACH soil, whereas AIR soil contained 5 to 14 x 10(3) nematodes (all bacteriovores) kg(-1). Active microbial biomass was four to five times higher in AIR than LEACH soil. Proteobacteria and actinomycetes/sulfate-reducing bacteria constituted a higher proportion of the community in AIR soil, whereas anaerobic Gram-negative bacteria/firmicutes were more prominent in LEACH soil. Ratios of prokaryotic to eukaryotic phospholipid fatty acids (PLFAs) were higher in LEACH soil, as were membrane stress index values, whereas the starvation index was higher in AIR soil. Community-level physiological profiles showed that 29 and 30 different substrates were used for growth by LEACH and AIR soil microorganisms, respectively. The AIR soil had more microorganisms capable of growing on 10 substrates, whereas growth on two substrates was higher in LEACH soil. Polymerase chain reaction-denaturing gradient gel electrophoresis (PCR-DGGE) analysis of 16S rRNA gene fragments revealed greater diversity of dominant phylotypes in AIR than LEACH soil, with communities separated by treatment. Aerated leachfield soil had a larger and more diverse faunal and microbial community than unaerated soil, possibly due to differences in the type and availability of electron acceptors.

  8. A Trade Study of Two Membrane-Aerated Biological Water Processors

    NASA Technical Reports Server (NTRS)

    Allada, Ram; Lange, Kevin; Vega. Leticia; Roberts, Michael S.; Jackson, Andrew; Anderson, Molly; Pickering, Karen

    2011-01-01

    Biologically based systems are under evaluation as primary water processors for next generation life support systems due to their low power requirements and their inherent regenerative nature. This paper will summarize the results of two recent studies involving membrane aerated biological water processors and present results of a trade study comparing the two systems with regards to waste stream composition, nutrient loading and system design. Results of optimal configurations will be presented.

  9. Effects of the combination of aeration and biofilm technology on transformation of nitrogen in black-odor river.

    PubMed

    Pan, Mei; Zhao, Jun; Zhen, Shucong; Heng, Sheng; Wu, Jie

    2016-01-01

    Excess nitrogen in urban river networks leading to eutrophication has become one of the most urgent environmental problems. Combinations of different aeration and biofilm techniques was designed to remove nitrogen from rivers. In laboratory water tank simulation experiments, we assessed the removal efficiency of nitrogen in both the overlying water and sediments by using the combination of the aeration and biofilm techniques, and then analyzed the transformation of nitrogen during the experiments. Aeration (especially sediment aeration) combined with the biofilms techniques was proved efficient in removing nitrogen from polluted rivers. Results indicated that the combination of sediment aeration and biofilms, with the highest nitrogen removal rate from the overlying water and sediments, was the most effective combined process, which especially inhibited the potential release of nitrogen from sediments by reducing the enzyme activity. It was found that the content of dissolved oxygen in water could be restored on the basis of the application of aeration techniques ahead, and the biofilm technique would be effective in purifying water in black-odor rivers. PMID:27508370

  10. Effects of the combination of aeration and biofilm technology on transformation of nitrogen in black-odor river.

    PubMed

    Pan, Mei; Zhao, Jun; Zhen, Shucong; Heng, Sheng; Wu, Jie

    2016-01-01

    Excess nitrogen in urban river networks leading to eutrophication has become one of the most urgent environmental problems. Combinations of different aeration and biofilm techniques was designed to remove nitrogen from rivers. In laboratory water tank simulation experiments, we assessed the removal efficiency of nitrogen in both the overlying water and sediments by using the combination of the aeration and biofilm techniques, and then analyzed the transformation of nitrogen during the experiments. Aeration (especially sediment aeration) combined with the biofilms techniques was proved efficient in removing nitrogen from polluted rivers. Results indicated that the combination of sediment aeration and biofilms, with the highest nitrogen removal rate from the overlying water and sediments, was the most effective combined process, which especially inhibited the potential release of nitrogen from sediments by reducing the enzyme activity. It was found that the content of dissolved oxygen in water could be restored on the basis of the application of aeration techniques ahead, and the biofilm technique would be effective in purifying water in black-odor rivers.

  11. The effect of aeration and effluent recycling on domestic wastewater treatment in a pilot-plant system of duckweed ponds.

    PubMed

    Ben-shalom, Miriam; Shandalov, Semion; Brenner, Asher; Oron, Gideon

    2014-01-01

    Three pilot-scale duckweed pond (DP) wastewater treatment systems were designed and operated to examine the effect of aeration and effluent recycling on treatment efficiency. Each system consisted of two DPs in series fed by pre-settled domestic sewage. The first system (duckweed+ conventional treatment) was 'natural' and included only duckweed plants. The second system (duckweed aeration) included aeration in the second pond. The third system (duckweed+ aeration+ circulation) included aeration in the second pond and effluent recycling from the second to the first pond. All three systems demonstrated similarly efficient removal of organic matter and nutrients. Supplemental aeration had no effect on either dissolved oxygen levels or on pollutant removal efficiencies. Although recycling had almost no influence on nutrient removal efficiencies, it had a positive impact on chemical oxygen demand and total suspended solids removals due to equalization of load and pH, which suppressed algae growth. Recycling also improved the appearance and growth rate of the duckweed plants, especially during heavy wastewater loads.

  12. Relationship between respiratory quotient, nitrification, and nitrous oxide emissions in a forced aerated composting process

    SciTech Connect

    Tsutsui, Hirofumi; Fujiwara, Taku; Inoue, Daisuke; Ito, Ryusei; Matsukawa, Kazutsugu; Funamizu, Naoyuki

    2015-08-15

    Highlights: • RQ can be an indicator of N{sub 2}O emission in forced aerated composting process. • Emission of N{sub 2}O with nitrification was observed with RQ decrease. • Mass balances demonstrated the RQ decrease was caused by nitrification. • Conversion ratio of oxidized ammonia and total N to N{sub 2}O were ∼2.7%. - Abstract: We assessed the relationship between respiratory quotient (RQ) and nitrification and nitrous oxide (N{sub 2}O) emission in forced aerated composting using lab-scale reactors. Relatively high RQ values from degradation of readily degradable organics initially occurred. RQ then stabilized at slightly lower values, then decreased. Continuous emission of N{sub 2}O was observed during the RQ decrease. Correlation between nitrification and N{sub 2}O emission shows that the latter was triggered by nitrification. Mass balances demonstrated that the O{sub 2} consumption of nitrification (∼24.8 mmol) was slightly higher than that of CO{sub 2} emission (∼20.0 mmol), indicating that the RQ decrease was caused by the occurrence of nitrification. Results indicate that RQ is a useful index, which not only reflects the bioavailability of organics but also predicts the occurrence of nitrification and N{sub 2}O emission in forced aerated composting.

  13. Power generation from cassava alcohol wastewater: effects of pretreatment and anode aeration.

    PubMed

    Quan, Xiangchun; Tao, Kun; Mei, Ying; Jiang, Xiaoman

    2014-11-01

    Cassava alcohol wastewater produced from the bioethanol production industry is carbohydrate-rich wastewater with large quantities of insoluble organic compounds. Microbial fuel cells (MFCs) were used for electricity recovery and pollutants removal from this wastewater. Different pretreatment methods (solid-liquid separation, ultrasonication, pre-fermentation) and anode-aeration modes were explored in MFCs aimed to enhance the efficiency of power generation and pollutants removal. Pre-fermentation was found to be the most effective pretreatment method. A maximum power density of 437.13 ± 15.6 mW/m(2) and TCOD removal of 62.5 ± 3.5% were achieved using the pre-fermented wastewater, 150 and 20% higher than the un-pretreated control. Aeration in anode chamber could promote the hydrolysis of organic matter and production of VFAs in the raw wastewater, and increase TCOD removal and power density. Pre-fermentation coupled with halfway anode aeration may be a feasible strategy to enhance power generation and pollutants removal from the cassava wastewater in MFCs. PMID:24842224

  14. Evaluation of aerated biofilter systems for microbial methane oxidation of poor landfill gas.

    PubMed

    Haubrichs, R; Widmann, R

    2006-01-01

    In the long-term, landfills are producing landfill gas (LFG) with low calorific values. Therefore, the utilization of LFG in combined heat and power plants (CHP) is limited to a certain period of time. A feasible method for LFG treatment is microbial CH(4) oxidation. Different materials were tested in actively aerated lab-scale bio-filter systems with a volume of 0.167 m(3). The required oxygen for the microbial CH(4) oxidation was provided through perforated probes, which distributed ambient air into the filter material. Three air input levels were installed along the height of the filter, each of them adjusted to a particular flow rate. During the tests, stable degradation rates of around 28 g/(m(3) h) in a fine-grained compost material were observed at a CH(4) inlet concentration of 30% over a period of 148 days. Compared with passive (not aerated) tests, the CH(4) oxidation rate increased by a factor of 5.5. Therefore, the enhancement of active aeration on the microbial CH(4) oxidation was confirmed. At a O(2)/CH(4) ratio of 2.5, nearly 100% of the CH(4) load was decomposed. By lowering the ratio from 2.5 to 2, the efficiency fell to values from 88% to 92%. By varying the distribution to the three air input levels, the CH(4) oxidation process was spread more evenly over the filter volume. PMID:16386886

  15. Mechanism and design of intermittent aeration activated sludge process for nitrogen removal.

    PubMed

    Hanhan, Oytun; Insel, Güçlü; Yagci, Nevin Ozgur; Artan, Nazik; Orhon, Derin

    2011-01-01

    The paper provided a comprehensive evaluation of the mechanism and design of intermittent aeration activated sludge process for nitrogen removal. Based on the specific character of the process the total cycle time, (T(C)), the aerated fraction, (AF), and the cycle time ratio, (CTR) were defined as major design parameters, aside from the sludge age of the system. Their impact on system performance was evaluated by means of process simulation. A rational design procedure was developed on the basis of basic stochiometry and mass balance related to the oxidation and removal of nitrogen under aerobic and anoxic conditions, which enabled selected of operation parameters of optimum performance. The simulation results indicated that the total nitrogen level could be reduced to a minimum level by appropriate manipulation of the aerated fraction and cycle time ratio. They also showed that the effluent total nitrogen could be lowered to around 4.0 mgN/L by adjusting the dissolved oxygen set-point to 0.5 mg/L, a level which promotes simultaneous nitrification and denitrification.

  16. Evaluation of aerated biofilter systems for microbial methane oxidation of poor landfill gas.

    PubMed

    Haubrichs, R; Widmann, R

    2006-01-01

    In the long-term, landfills are producing landfill gas (LFG) with low calorific values. Therefore, the utilization of LFG in combined heat and power plants (CHP) is limited to a certain period of time. A feasible method for LFG treatment is microbial CH(4) oxidation. Different materials were tested in actively aerated lab-scale bio-filter systems with a volume of 0.167 m(3). The required oxygen for the microbial CH(4) oxidation was provided through perforated probes, which distributed ambient air into the filter material. Three air input levels were installed along the height of the filter, each of them adjusted to a particular flow rate. During the tests, stable degradation rates of around 28 g/(m(3) h) in a fine-grained compost material were observed at a CH(4) inlet concentration of 30% over a period of 148 days. Compared with passive (not aerated) tests, the CH(4) oxidation rate increased by a factor of 5.5. Therefore, the enhancement of active aeration on the microbial CH(4) oxidation was confirmed. At a O(2)/CH(4) ratio of 2.5, nearly 100% of the CH(4) load was decomposed. By lowering the ratio from 2.5 to 2, the efficiency fell to values from 88% to 92%. By varying the distribution to the three air input levels, the CH(4) oxidation process was spread more evenly over the filter volume.

  17. Computational Fluid Dynamics Simulation of Flows in an Oxidation Ditch Driven by a New Surface Aerator

    PubMed Central

    Huang, Weidong; Li, Kun; Wang, Gan; Wang, Yingzhe

    2013-01-01

    Abstract In this article, we present a newly designed inverse umbrella surface aerator, and tested its performance in driving flow of an oxidation ditch. Results show that it has a better performance in driving the oxidation ditch than the original one with higher average velocity and more uniform flow field. We also present a computational fluid dynamics model for predicting the flow field in an oxidation ditch driven by a surface aerator. The improved momentum source term approach to simulate the flow field of the oxidation ditch driven by an inverse umbrella surface aerator was developed and validated through experiments. Four kinds of turbulent models were investigated with the approach, including the standard k−ɛ model, RNG k−ɛ model, realizable k−ɛ model, and Reynolds stress model, and the predicted data were compared with those calculated with the multiple rotating reference frame approach (MRF) and sliding mesh approach (SM). Results of the momentum source term approach are in good agreement with the experimental data, and its prediction accuracy is better than MRF, close to SM. It is also found that the momentum source term approach has lower computational expenses, is simpler to preprocess, and is easier to use. PMID:24302850

  18. [Treatment of petrochemical secondary effluent by ozone-biological aerated filter].

    PubMed

    Liu, Ming-Guo; Wu, Chang-Yong; Zhou, Yue-Xi; Gao, Zhen; Wang, Pei-Chao; Yang, Qi; Dong, De

    2014-02-01

    The advanced treatment of petrochemical secondary wastewater by ozone- aerated biological filter was carried out in this study. The effect of pH on ozonation and the removal of COD and UV254 by the ozone-aerated biological filter combined process were investigated. In addition, the variation of relative molecular mass distribution of organics and the characteristics of three-dimensional fluorescence spectra of the wastewater were also investigated. The results showed that the suitable operating conditions of the ozonation unit were: ozone dosage 10 mg x L(-1), contact time 4 min and slightly alkaline pH. Ozonation can transfer macromolecular organics into small molecular organics, resulting in a 15% increase in the percentage of the organics with small relative molecular mass (less than 1 000). The biodegradability of the petrochemical secondary effluent was significantly improved by ozonation, making it more suitable for the treatment by aerated biological filter. The removal efficiency of COD and UV254 were 40.8% and 45.8% when the hydraulic retention time was 3 hours and the gas to water ratio was 3:1 for BAF. The average COD of the petrochemical wastewater was 86.5 mg x L(-1) while the average COD of the effluent of the combined process was 49.4 mg x L(-1) when it was operated under optimal conditions.

  19. Treatment of sewage sludge in a thermophilic membrane reactor (TMR) with alternate aeration cycles.

    PubMed

    Collivignarelli, Maria Cristina; Castagnola, Federico; Sordi, Marco; Bertanza, Giorgio

    2015-10-01

    The management of sewage sludge is becoming a more and more important issue, both at national and international level, in particular due to the uncertain recovery/disposal future options. Therefore, it is clear that the development of new technologies that can mitigate the problem at the source by reducing sludge production is necessary, such as the European Directive 2008/98/EC prescribes. This work shows the results obtained with a thermophilic membrane reactor, for processing a biological sludge derived from a wastewater treatment plant (WWTP) that treats urban and industrial wastewater. Sewage sludge was treated in a thermophilic membrane reactor (TMR), at pilot-scale (1 m(3) volume), with alternate aeration cycles. The experimentation was divided into two phases: a "startup phase" during which, starting with a psychrophilic/mesophilic biomass, thermophilic conditions were progressively reached, while feeding a highly biodegradable substrate; the obtained thermophilic biomass was then used, in the "regime phase", to digest biological sludge which was fed to the plant. Good removal yields were observed: 64% and 57% for volatile solids (VS) and total COD (CODtot), respectively, with an average hydraulic retention time (HRT) equal to 20 d, an organic loading rate (OLR) of about 1.4-1.8 kg COD m(-3) d(-1) and aeration/non aeration cycles alternated every 4 h.

  20. Multiple electron transfer systems in oxygen reducing biocathodes revealed by different conditions of aeration/agitation.

    PubMed

    Rimboud, Mickaël; Bergel, Alain; Erable, Benjamin

    2016-08-01

    Oxygen reducing biocathodes were formed at -0.2V/SCE (+0.04V/SHE) from compost leachate. Depending on whether aeration was implemented or not, two different redox systems responsible for the electrocatalysis of oxygen reduction were evidenced. System I was observed at low potential (-0.03V/SHE) on cyclic voltammetries (CVs). It appeared during the early formation of the biocathode (few hours) and resisted the hydrodynamic conditions induced by the aeration. System II was observed at higher potential on CV (+0.46V/SHE); it required a longer lag time (up to 10days) and quiescent conditions to produce an electrochemical signal. The hydrodynamic effects produced by the forced aeration led to its extinction. From their different behaviors and examples in the literature, system I was identified as being a membrane-bound cytochrome-related molecule, while system II was identified as a soluble redox mediator excreted by the biofilm. This study highlighted the importance of controlling the local hydrodynamics to design efficient oxygen reducing biocathodes able to operate at high potential.

  1. Bio-oxidation of airborne volatile organic compounds in an activated sludge aeration tank.

    PubMed

    Chou, Ming-Shean; Chang, Hsiao-Yu

    2005-05-01

    An activated sludge aeration tank (40 x 40 x 300 cm, width x length x height) with a set of 2-mm orifice air spargers was used to treat gas-borne volatile organic compounds (VOCs; toluene, p-xylene, and dichloromethane) in air streams. The effects of liquid depth (Z), aeration intensity (G/A), the overall mass-transfer rate of oxygen in clean water (KLaO2), the Henry's law constant of the tested VOC (H), and the influent gaseous VOC concentration (C0) on the efficiency of removal of VOCs were examined and compared with a literature-cited model. Results show that the measured VOC removal efficiencies and those predicted by the model were comparable at a G/A of 3.75-11.25 m3/m2 hr and C0 of approximately 1000-6000 mg/m3. Experimental data also indicated that the designed gas treatment reactor with KLaO2 = 5-15 hr(-l) could achieve > 85% removal of VOCs with H = 0.24-0.25 at an aerated liquid depth of 1 m and > 95% removal of dichloromethane with H = 0.13 at a 1-m liquid depth.

  2. Impact of carbon to nitrogen ratio and aeration regime on mainstream deammonification.

    PubMed

    Han, M; De Clippeleir, H; Al-Omari, A; Wett, B; Vlaeminck, S E; Bott, C; Murthy, S

    2016-01-01

    While deammonification of high-strength wastewater in the sludge line of sewage treatment plants has become well established, the potential cost savings spur the development of this technology for mainstream applications. This study aimed at identifying the effect of aeration and organic carbon on the deammonification process. Two 10 L sequencing bath reactors with different aeration frequencies were operated at 25°C. Real wastewater effluents from chemically enhanced primary treatment and high-rate activated sludge process were fed into the reactors with biodegradable chemical oxygen demand/nitrogen (bCOD/N) of 2.0 and 0.6, respectively. It was found that shorter aerobic solids retention time (SRT) and higher aeration frequency gave more advantages for aerobic ammonium-oxidizing bacteria (AerAOB) than nitrite oxidizing bacteria (NOB) in the system. From the kinetics study, it is shown that the affinity for oxygen is higher for NOB than for AerAOB, and higher dissolved oxygen set-point could decrease the affinity of both AerAOB and NOB communities. After 514 days of operation, it was concluded that lower organic carbon levels enhanced the activity of anoxic ammonium-oxidizing bacteria (AnAOB) over denitrifiers. As a result, the contribution of AnAOB to nitrogen removal increased from 40 to 70%. Overall, a reasonably good total removal efficiency of 66% was reached under a low bCOD/N ratio of 2.0 after adaptation. PMID:27438242

  3. Effect of forced aeration on citric acid production by Aspergillus sp. mutants in SSF.

    PubMed

    Rodrigues, Cristine; Vandenberghe, Luciana P S; Sturm, Wilerson; Dergint, Dario E A; Spier, Michele Rigon; de Carvalho, Júlio Cesar; Soccol, Carlos R

    2013-12-01

    Citric acid (CA) is one of the most important products of fermentation in the world. A great variety of agro-industrial residues can be used in solid state fermentation. Aspergillus niger parental strain (CCT 7716) and two strains obtained by mutagenesis (CCT 7717 and CCT 7718) were evaluated in Erlenmeyer flasks and glass columns using citric pulp (CP) as substrate/support, sugarcane molasses and methanol. Best results using glass columns (forced aeration) were found in the fourth day of fermentation: 278.4, 294.9 and 261.1 g CA/kg of dry CP with CCT 7716, CCT 7718 and CCT 7717, respectively. In Erlenmeyer flasks (aeration by diffusion) CA reached 410.7, 446.8 and 492.7 g CA/kg of dry CP with CCT 7716, CCT 7718 and CCT 7717, respectively. The aeration by diffusion improved CA production by the three strains. A data acquisition system specially developed for biotechnological processes analysis was used to perform the respirometric parameters measurement.

  4. Thermophilic aeration of cattle slurry with whey and/or jam wastes.

    PubMed

    Heinonen-Tanski, Helvi; Kiuru, Tapio; Ruuskanen, Juhani; Korhonen, Kari; Koivunen, Jari; Ruokojärvi, Arja

    2005-01-01

    Thermophilic aeration of cattle slurry and food industrial by-products was studied with the aim to improve hygienic qualities of the slurry so that it could be used as a safe fertiliser for berries to be eaten raw. We also wanted to study if the process would be energetically favourable in an arctic climate. Cattle slurry alone or with whey and/or jam waste was treated. The tests were done in a well heat-insulated reactor with a 10 m(3) volume. Temperature increases up to over 70 degrees C could be recorded in 19 days even though some processes were carried out in winter time when the ambient air temperature was less than 0 degrees C. The heat energy formed was higher than the electrical energy needed to carry out the aeration. The hygienic qualities of the aerated product were good with only minor nitrogen losses. The end product could be useful as a fertiliser and soil improving compound to increase the organic matter content of agricultural soil. Cattle slurry alone was well suited as the raw material if attaining a high temperature was the main goal. A part of slurry could be replaced with food-industrial side products. Whey waste suited better for co-composting than jam waste but the mixture of whey, jam waste, and slurry was optimal for composting.

  5. Power generation from cassava alcohol wastewater: effects of pretreatment and anode aeration.

    PubMed

    Quan, Xiangchun; Tao, Kun; Mei, Ying; Jiang, Xiaoman

    2014-11-01

    Cassava alcohol wastewater produced from the bioethanol production industry is carbohydrate-rich wastewater with large quantities of insoluble organic compounds. Microbial fuel cells (MFCs) were used for electricity recovery and pollutants removal from this wastewater. Different pretreatment methods (solid-liquid separation, ultrasonication, pre-fermentation) and anode-aeration modes were explored in MFCs aimed to enhance the efficiency of power generation and pollutants removal. Pre-fermentation was found to be the most effective pretreatment method. A maximum power density of 437.13 ± 15.6 mW/m(2) and TCOD removal of 62.5 ± 3.5% were achieved using the pre-fermented wastewater, 150 and 20% higher than the un-pretreated control. Aeration in anode chamber could promote the hydrolysis of organic matter and production of VFAs in the raw wastewater, and increase TCOD removal and power density. Pre-fermentation coupled with halfway anode aeration may be a feasible strategy to enhance power generation and pollutants removal from the cassava wastewater in MFCs.

  6. Mechanism and design of intermittent aeration activated sludge process for nitrogen removal.

    PubMed

    Hanhan, Oytun; Insel, Güçlü; Yagci, Nevin Ozgur; Artan, Nazik; Orhon, Derin

    2011-01-01

    The paper provided a comprehensive evaluation of the mechanism and design of intermittent aeration activated sludge process for nitrogen removal. Based on the specific character of the process the total cycle time, (T(C)), the aerated fraction, (AF), and the cycle time ratio, (CTR) were defined as major design parameters, aside from the sludge age of the system. Their impact on system performance was evaluated by means of process simulation. A rational design procedure was developed on the basis of basic stochiometry and mass balance related to the oxidation and removal of nitrogen under aerobic and anoxic conditions, which enabled selected of operation parameters of optimum performance. The simulation results indicated that the total nitrogen level could be reduced to a minimum level by appropriate manipulation of the aerated fraction and cycle time ratio. They also showed that the effluent total nitrogen could be lowered to around 4.0 mgN/L by adjusting the dissolved oxygen set-point to 0.5 mg/L, a level which promotes simultaneous nitrification and denitrification. PMID:21104491

  7. Effects of etiologically defined respiratory infections on lung function and its growth in an area of low air pollution - spirometry in young children when illness-free

    SciTech Connect

    Collier, A.M.; Strope, G.L.; Helms, R.W.; LaVange, L.M.; Clyde, W.A. Jr.

    1981-03-01

    This longitudinal study was performed in a group of 3-12 year old children to document normal lung growth patterns as measured by spirometry. By clinical and laboratory parameters, these children were free of illness at the time of study and had been for the preceding 21 days. Spirometry was performed prospectively over a period of six years in 69 children (27 black females, 23 black males, 10 white females, and 9 white males) all from a day care center. Eight hundred fifteen spirometric tests were made on these children. Six spirometric parameters were measured: forced vital capacity (FVC), forced expiratory volume in one second (FEV1), peak expiratory flow (PEF), forced expiratory flow during the middle half of the FVC (FEF25-75%), and maximum expiratory flows after 50% and 75% of the FVC have been exhaled (Vmax50% and Vmax75%, respectively). There were significant differences between the regression lines (considering slope and intercept) for all six parameters when black females were compared to black males, white females to white males, black females to white females and black males to white males, except for Vmax75% for the comparison of black females to black males and white females to white males. These slopes and intercepts were similar to those reported by others for children of similar age and height. This study demonstrates that spirometry can be performed reliabley at an early age in a day care center population, that there are significant racial and sexual differences in spirometric volume and flow parameters and that the variability of these measurements is proportional to height rather than being a constant.

  8. Estimation of lung tissue incompressibility variation throughout respiration for tumor targeting in lung radiotherapy

    NASA Astrophysics Data System (ADS)

    Shirzadi, Zahra; Samani, Abbas

    2013-03-01

    A novel technique is proposed to characterize lung tissue incompressibility variation during respiration. Lung tissue incompressibility variation stems from significant air content variation in the tissue throughout respiration. Estimating lung tissue incompressibility and its variation is critical for computer assisted tumor motion tracking. Continuous tumor motion during respiration is a major challenge in lung cancer treatment by external beam radiotherapy. If not accounted for, this motion leads to areas of radiation over dosage for the lung normal tissues. Since no effective imaging modality is available for real-time lung tumor tracking, computer based modeling which has the capability for accurate tissue deformation estimation can be a good alternative. Lung tissue deformation estimation can be made using the lung Finite Element (FE) model where its accuracy depends on input tissue biomechanical properties including incompressibility parameter. In this research, an optimization algorithm is proposed to estimate the incompressibility parameter function in terms of respiration cycle time. In this algorithm, the incompressibility parameter and lung pressure values are varied systematically until optimal values, which result in maximum similarity between acquired and simulated 4D CT images of the lung, are achieved for each respiration time point. The simulated images are constructed using a reference image in conjunction with the deformation field obtained from the lung's FE model in each respiration time increment. We demonstrated that utilizing the calculated function along with respiratory system FE modeling leads to accurate tumor targeting, hence potentially improving lung radiotherapy outcome.

  9. Changes in lung vascular permeability after heart-lung transplantation.

    PubMed

    Mancini, M C; Borovetz, H S; Griffith, B P; Hardesty, R L

    1985-10-01

    We have employed multiple indicator dilution techniques (MID) in six patients after heart-lung transplantation to assess changes in the lung vascular permeability-surface area product for urea (PS). Serial PS values for the patients when normalized to the predicted total lung capacity (TLC) in liters, ranged between 1.04 and 6.27 ml/sec/TLC (patient 1), 0 and 2.76 ml/sec/TLC (patient 2), 0.59 and 2.88 ml/sec/TLC (patient 3), 0.13 and 1.23 ml/sec/TLC (patient 4). The elevated values for PS in patient 1 exceed the lethal range described by K.L. Brigham et al. (J. Clin. Invest. 72:339, 1983) for severe ARDS. This strongly suggests a severely increased lung microvascular permeability in this patient possibly secondary to rejection as indicated by endomyocardial biopsy. PS values for surviving patients 2-6 fell well below the corresponding lethal value for ARDS patients. We conclude that PS urea derived from MID provides an indicator of the status of lung microvascular integrity in heart-lung transplant recipients.

  10. Rheumatoid lung disease

    MedlinePlus

    Lung disease - rheumatoid arthritis; Rheumatoid nodules; Rheumatoid lung ... Elsevier Saunders; 2016:chap 65. Lake F, Proudman S. Rheumatoid arthritis and lung disease: from mechanisms to a practical approach. Semin Respir ...

  11. How Lungs Work

    MedlinePlus

    ... Health and Diseases > How Lungs Work How Lungs Work The Respiratory System Your lungs are part of ... Parts of the Respiratory System and How They Work Airways SINUSES are hollow spaces in the bones ...

  12. Lung Carcinoid Tumor: Surgery

    MedlinePlus

    ... for lung carcinoid tumor symptoms Surgery to treat lung carcinoid tumors Surgery is the main treatment for ... often be cured by surgery alone. Types of lung surgery Different operations can be used to treat ( ...

  13. Lung surgery - discharge

    MedlinePlus

    Thoracotomy - discharge; Lung tissue removal - discharge; Pneumonectomy - discharge; Lobectomy - discharge; Lung biopsy - discharge; Thoracoscopy - discharge; Video-assisted thoracoscopic surgery - discharge; VATS - ...

  14. Interstitial lung disease

    MedlinePlus

    Diffuse parenchymal lung disease; Alveolitis; Idiopathic pulmonary pneumonitis (IPP) ... The lungs contain tiny air sacs (alveoli), which is where oxygen is absorbed. These air sacs expand with each ...

  15. Lung Circulation.

    PubMed

    Suresh, Karthik; Shimoda, Larissa A

    2016-04-01

    The circulation of the lung is unique both in volume and function. For example, it is the only organ with two circulations: the pulmonary circulation, the main function of which is gas exchange, and the bronchial circulation, a systemic vascular supply that provides oxygenated blood to the walls of the conducting airways, pulmonary arteries and veins. The pulmonary circulation accommodates the entire cardiac output, maintaining high blood flow at low intravascular arterial pressure. As compared with the systemic circulation, pulmonary arteries have thinner walls with much less vascular smooth muscle and a relative lack of basal tone. Factors controlling pulmonary blood flow include vascular structure, gravity, mechanical effects of breathing, and the influence of neural and humoral factors. Pulmonary vascular tone is also altered by hypoxia, which causes pulmonary vasoconstriction. If the hypoxic stimulus persists for a prolonged period, contraction is accompanied by remodeling of the vasculature, resulting in pulmonary hypertension. In addition, genetic and environmental factors can also confer susceptibility to development of pulmonary hypertension. Under normal conditions, the endothelium forms a tight barrier, actively regulating interstitial fluid homeostasis. Infection and inflammation compromise normal barrier homeostasis, resulting in increased permeability and edema formation. This article focuses on reviewing the basics of the lung circulation (pulmonary and bronchial), normal development and transition at birth and vasoregulation. Mechanisms contributing to pathological conditions in the pulmonary circulation, in particular when barrier function is disrupted and during development of pulmonary hypertension, will also be discussed. PMID:27065170

  16. Coupling of bio-PRB and enclosed in-well aeration system for remediation of nitrobenzene and aniline in groundwater.

    PubMed

    Liu, Na; Ding, Feng; Wang, Liu; Liu, Peng; Yu, Xiaolong; Ye, Kang

    2016-05-01

    A laboratory-scale bio-permeable reactive barrier (bio-PRB) was constructed and combined with enclosed in-well aeration system to treat nitrobenzene (NB) and aniline (AN) in groundwater. Batch-style experiments were first conducted to evaluate the effectiveness of NB and AN degradation, using suspension (free cells) of degrading consortium and immobilized consortium by a mixture of perlite and peat. The NB and AN were completely degraded in <3 days using immobilized consortium, while 3-5 days were required using free cells. The O2 supply efficiency of an enclosed in-well aeration system was assessed in a box filled with perlite and peat. Dissolved O2 (DO) concentrations increased to 8-12 mg L(-1) in 12 h for sampling ports within 12 cm of the aeration well. A diffusion coefficient as 33.5 cm(2) s(-1) was obtained. The DO concentration was >4 mg L(-1) when the aeration system was applied into the bio-PRB system. The NB and AN were effectively removed when the aeration system was functional in the bio-PRB. The removal efficiency decreased when the aeration system malfunctioned for 20 days, thus indicating that DO was an important factor for the degradation of NB and AN. The regain of NB and AN removal after the malfunction indicates the robustness of degradation consortium. No original organics and new formed by-products were observed in the effluent. The results indicate that NB and AN in groundwater can be completely mineralized in a bio-PRB equipped with enclosed in-well aeration system and filled with perlite and peat attached with degrading consortium.

  17. Changes in the chemical and physicochemical properties of the solid fraction of cattle slurry during composting using different aeration strategies.

    PubMed

    Cáceres, Rafaela; Flotats, Xavier; Marfà, Oriol

    2006-01-01

    Replacement of peat as a growing medium by a renewable material, such as an organic waste, is an issue of concern since harvesting of peat has a considerable environmental impact and, actually, it is a non-renewable resource. Cattle manure is a readily available organic waste, which means that once it goes through the composting process, it can be used as an alternative to peat, specifically, the solid fraction obtained from mechanical liquid-solid separation of cattle slurry (SF). Studies have shown it to be suitable for such uses. The purpose of this study was to detect possible changes in the physicochemical and chemical properties of SF when it is composted using different aeration strategies, with an emphasis on the changes that would make it feasible for use as a substrate. With this aim in mind, an experiment was designed with three aeration strategies that would be used during composting. The first consisted of applying air through a static method (forced ventilation). The second involved improving aeration by adding a bulking agent and a dynamic turning method. In the third strategy, aeration was carried out by turning (control). The results show that the different aeration strategies had a clear effect on the evolution of pH, electrical conductivity (EC), nitrate-N, ammonia-N and bicarbonate content. Nitrification was favored under good aeration conditions using the static composting method, probably due to the greater availability of ammonia-N that was transformed into nitrate-N. In general, the low buffering capacity allowed for a reduction of the pH during the curing stage of composting (in conjunction with low temperatures during this period), a characteristic that favors the use of this compost as a growing medium. We also conclude that measuring bicarbonate levels during composting could be used as an indicator of the possible acidification of the material and as a way of evaluating the level of material aeration. PMID:16146687

  18. Changes in the chemical and physicochemical properties of the solid fraction of cattle slurry during composting using different aeration strategies.

    PubMed

    Cáceres, Rafaela; Flotats, Xavier; Marfà, Oriol

    2006-01-01

    Replacement of peat as a growing medium by a renewable material, such as an organic waste, is an issue of concern since harvesting of peat has a considerable environmental impact and, actually, it is a non-renewable resource. Cattle manure is a readily available organic waste, which means that once it goes through the composting process, it can be used as an alternative to peat, specifically, the solid fraction obtained from mechanical liquid-solid separation of cattle slurry (SF). Studies have shown it to be suitable for such uses. The purpose of this study was to detect possible changes in the physicochemical and chemical properties of SF when it is composted using different aeration strategies, with an emphasis on the changes that would make it feasible for use as a substrate. With this aim in mind, an experiment was designed with three aeration strategies that would be used during composting. The first consisted of applying air through a static method (forced ventilation). The second involved improving aeration by adding a bulking agent and a dynamic turning method. In the third strategy, aeration was carried out by turning (control). The results show that the different aeration strategies had a clear effect on the evolution of pH, electrical conductivity (EC), nitrate-N, ammonia-N and bicarbonate content. Nitrification was favored under good aeration conditions using the static composting method, probably due to the greater availability of ammonia-N that was transformed into nitrate-N. In general, the low buffering capacity allowed for a reduction of the pH during the curing stage of composting (in conjunction with low temperatures during this period), a characteristic that favors the use of this compost as a growing medium. We also conclude that measuring bicarbonate levels during composting could be used as an indicator of the possible acidification of the material and as a way of evaluating the level of material aeration.

  19. The use of an aeration system to prevent thermal stratification of a freshwater impoundment and its effect on downstream fish assemblages.

    PubMed

    Miles, N G; West, R J

    2011-03-01

    Warm-water riverine fish assemblages were investigated downstream of an impoundment before and after thermal stratification and the associated cold-water pollution was prevented using an aeration system. Temperatures below the dam significantly increased after installation of the aeration system and this correlated with an increased abundance and greater number of species downstream. Overall, aeration appeared to be beneficial for both the lake (upstream) and the downstream riverine environments.

  20. Who Needs a Lung Transplant?

    MedlinePlus

    ... from the NHLBI on Twitter. Who Needs a Lung Transplant? Your doctor may recommend a lung transplant ... lungs to pick up oxygen. Applying to a Lung Transplant Program Lung transplants are done in medical ...

  1. Fe hydroxyphosphate precipitation and Fe(II) oxidation kinetics upon aeration of Fe(II) and phosphate-containing synthetic and natural solutions

    NASA Astrophysics Data System (ADS)

    van der Grift, B.; Behrends, T.; Osté, L. A.; Schot, P. P.; Wassen, M. J.; Griffioen, J.

    2016-08-01

    Exfiltration of anoxic Fe-rich groundwater into surface water and the concomitant oxidative precipitation of Fe are important processes controlling the transport of phosphate (PO4) from agricultural areas to aquatic systems. Here, we explored the relationship between solution composition, reaction kinetics, and the characteristics of the produced Fe hydroxyphosphate precipitates in a series of aeration experiments with anoxic synthetic water and natural groundwater. A pH stat device was used to maintain constant pH and to record the H+ production during Fe(II) oxidation in the aeration experiments in which the initial aqueous P/Fe ratios ((P/Fe)ini), oxygen concentration and pH were varied. In general, Fe(II) oxidation proceeded slower in the presence of PO4 but the decrease of the PO4 concentration during Fe(II) oxidation due to the formation of Fe hydroxyphosphates caused additional deceleration of the reaction rate. The progress of the reaction could be described using a pseudo-second-order rate law with first-order dependencies on PO4 and Fe(II) concentrations. After PO4 depletion, the Fe(II) oxidation rates increased again and the kinetics followed a pseudo-first-order rate law. The first-order rate constants after PO4 depletion, however, were lower compared to the Fe(II) oxidation in a PO4-free solution. Hence, the initially formed Fe hydroxyphosphates also affect the kinetics of continuing Fe(II) oxidation after PO4 depletion. Presence of aqueous PO4 during oxidation of Fe(II) led to the formation of Fe hydroxyphosphates. The P/Fe ratios of the precipitates ((P/Fe)ppt) and the recorded ratio of H+ production over decrease in dissolved Fe(II) did not change detectably throughout the reaction despite a changing P/Fe ratio in the solution. When (P/Fe)ini was 0.9, precipitates with a (P/Fe)ppt ratio of about 0.6 were formed. In experiments with (P/Fe)ini ratios below 0.6, the (P/Fe)ppt decreased with decreasing (P/Fe)ini and pH value. Aeration experiments with

  2. Comparisons of IL-8, ROS and p53 responses in human lung epithelial cells exposed to two extracts of PM2.5 collected from an e-waste recycling area, China

    NASA Astrophysics Data System (ADS)

    Yang, Fangxing; Jin, Shiwei; Xu, Ying; Lu, Yuanan

    2011-04-01

    To identify the different effects of organic-soluble and water-soluble pollutants adsorbed on PM2.5 (PM: particulate matter) released from e-waste (electrical/electronic waste) on inflammatory response, oxidative stress and DNA damage, interleukin-8 (IL-8), reactive oxygen species (ROS) and p53 protein levels were determined and compared in human lung epithelial A549 cells exposed to extracts of PM2.5 collected from two sampling sites in an e-waste recycling area in China. It is found that both extracts induced increases of IL-8 release, ROS production and p53 protein expression. The differences between the organic-soluble and water-soluble extracts were determined as of significance for ROS production (p < 0.05) and p53 protein expression (p < 0.01). The ROS production and p53 protein expression induced by the organic-soluble extracts were found to be greater than those induced by the water-soluble extracts, for both sampling sites. The results indicated that PM2.5 collected from the e-waste recycling areas could lead to inflammatory response, oxidative stress and DNA damage, and the organic-soluble extracts had higher potential to induce such adverse effects on human health.

  3. Remediation of Urban River Water by Pontederia Cordata Combined with Artificial Aeration: Organic Matter and Nutrients Removal and Root-Adhered Bacterial Communities.

    PubMed

    Gu, Dungang; Xu, Huan; He, Yan; Zhao, Feng; Huang, Minsheng

    2015-01-01

    Macrophyte combined with artificial aeration is a promising in situ remediation approach for urban rivers polluted with nutrients and organic matter. However, seasonal variations and aeration effects on phytoremediation performance and root-adhered microbial communities are still unclear. In this study, Pontederia cordata was used to treat polluted urban river water under various aeration intensities. Results showed that the highest removal efficiencies of chemical oxygen demand (COD(Cr)) and total nitrogen (TN) were attained under aeration of 30 L min(-1) in spring and summer and 15 L min(-1) in autumn, while total phosphorus (TP) removal reached maximum with aeration of 15 L min(-1) in all seasons. Moderate aeration was beneficial for increasing the diversity of root-adhered bacteria communities, and the shift of bacterial community structure was more pronounced in spring and autumn with varying aeration intensity. The dual effect, i.e. turbulence and dissolved oxygen (DO), of aeration on the removal of COD(Cr) and TN prevailed over the individual effect of DO, while DO was the most influential factor for TP removal and the root-adhered bacterial community diversity. P. cordata combined with 15 L min(-1) aeration was deemed to be the best condition tested in this study.

  4. Lung surfactant.

    PubMed Central

    Rooney, S A

    1984-01-01

    Aspects of pulmonary surfactant are reviewed from a biochemical perspective. The major emphasis is on the lipid components of surfactant. Topics reviewed include surfactant composition, cellular and subcellular sites as well as pathways of biosynthesis of phosphatidylcholine, disaturated phosphatidylcholine and phosphatidylglycerol. The surfactant system in the developing fetus and neonate is considered in terms of phospholipid content and composition, rates of precursor incorporation, activities of individual enzymes of phospholipid synthesis and glycogen content and metabolism. The influence of the following hormones and other factors on lung maturation and surfactant production is discussed: glucocorticoids, thyroid hormone, estrogen, prolactin, cyclic AMP, beta-adrenergic and cholinergic agonists, prostaglandins and growth factors. The influence of maternal diabetes, fetal sex, stress and labor are also considered. Nonphysiologic and toxic agents which influence surfactant in the fetus, newborn and adult are reviewed. PMID:6145585

  5. The effect of aeration and recirculation on a sand-based hybrid constructed wetland treating low-strength domestic wastewater.

    PubMed

    Zapater-Pereyra, M; Kyomukama, E; Namakula, V; van Bruggen, J J A; Lens, P N L

    2016-08-01

    The Duplex-constructed wetland (CW) is a hybrid system composed of a vertical flow (VF) CW on top of a horizontal flow filter (HFF). Each compartment is designed to play a different role: aerobic treatment in the VF CW due to intermittent feeding and anoxic treatment in the HFF due to saturated conditions. Three Duplex-CWs were used in this study: Control, Aerated and Recirculating. The role of each compartment was tested for pollutant removal and micro-invertebrate abundance. In all systems, the VF CW removed mainly organic matter, solids and NH4(+)-N. Pathogens were removed in both compartments. Likewise, total nitrogen removal occurred in both compartments, only the Recirculating HFF was not able to denitrify the nitrogen due to the slightly more oxic conditions as compared to the other systems. All systems met discharge guidelines for organic matter, but only the Control and Aerated systems met those for total nitrogen. At the applied loading rates, the pollutant removal was not significantly enhanced by the use of aeration and recirculation. Therefore, operation as in the Control system, without aeration or recirculation, is recommended for the tested Duplex-CWs. If artificial aeration will be used in CWs, the support material should be carefully selected to allow a proper air distribution. PMID:26732367

  6. Nitrogen and carbon removal from synthetic wastewater in a vertical structured-bed reactor under intermittent aeration.

    PubMed

    Moura, Rafael B; Damianovic, Márcia H R Z; Foresti, Eugenio

    2012-05-15

    The removal of nitrogen and organic matter using a single reactor has been a common focus of investigation, and reactors operated in batch mode and under intermittent aeration have attracted special attention. This study aimed to evaluate the application of a new reactor configuration consisting of a fixed-bed reactor that was operated under conditions of continuous feeding and intermittent aeration. The reactor was built using acrylic, with a working volume of 6.1L. The fixed bed used for biomass support was composed of polyurethane foam cylinders vertically oriented inside the reaction zone. The reactor was operated under intermittent aeration (2h aerated and 1h non-aerated) and a recirculation ratio Q(r)/Q=5. Three different operating conditions (Phase I, Phase II, and Phase III) corresponding to hydraulic retention times (HRT) of 12h, 8h, and 10h, respectively, were tested. In Phase I, the system achieved total nitrogen (TN) and chemical oxygen demand (COD) removal efficiencies of 82% and 89%, respectively. At HRTs of 8 h and 10 h, the reactor was unstable with respect to TN removal, and the average resultant removal efficiencies were 49% and 45%, respectively. However, COD removal efficiencies remained high with mean values of 85% and 88% for Phases II and III, respectively. Based on these results, it can be concluded that this new reactor configuration constitutes an alternative method for effective removal of organic matter and nitrogen from wastewater.

  7. Internal aeration of paddy field rice (Oryza sativa) during complete submergence---importance of light and floodwater O2.

    PubMed

    Winkel, Anders; Colmer, Timothy D; Ismail, Abdelbagi M; Pedersen, Ole

    2013-03-01

    Flash floods can submerge paddy field rice (Oryza sativa), with adverse effects on internal aeration, sugar status and survival. Here, we investigated the in situ aeration of roots of rice during complete submergence, and elucidated how underwater photosynthesis and floodwater pO(2) influence root aeration in anoxic soil. In the field, root pO(2) was measured using microelectrodes during 2 d of complete submergence. Leaf gas films that formed on the superhydrophobic leaves were left intact, or experimentally removed, to elucidate their effect on internal aeration. In darkness, root pO(2) declined to very low concentrations (0.24 kPa) and was strongly correlated with floodwater pO(2). In light, root pO(2) was high (14 kPa) and primarily a function of the incident light determining the rates of underwater net photosynthesis. Plants with intact leaf gas films maintained higher underwater net photosynthesis relative to plants without gas films when the submerged shoots were in light. During complete submergence, internal aeration of rice in the field relies on underwater photosynthesis during the day and entry of O(2) from the floodwater during the night. Leaf gas films enhance photosynthesis during submergence leading to improved O(2) production and sugar status, and therefore contribute to the submergence tolerance of rice.

  8. Toward an understanding of the effects of agitation and aeration on growth and laccases production by Pleurotus ostreatus.

    PubMed

    Tinoco-Valencia, Raunel; Gómez-Cruz, Cristina; Galindo, Enrique; Serrano-Carreón, Leobardo

    2014-05-10

    Mycelial growth and laccase production by Pleurotus ostreatus CP50 cultured in a 10-L mechanically agitated bioreactor were assessed through a 2(3) factorial experimental design. The main effects and interactions of three factors (agitation, aeration and copper induction) over five responses (μ, αLacc, βLacc, maximal volumetric laccase activity and maximal biomass concentration) were analyzed. P. ostreatus growth was significantly improved when culturing was conducted with high agitation (5.9kW/m(3)s) and aeration flow (0.5vvm) rates. Under the experimental conditions evaluated, no evidence of hydrodynamic stress affecting fungal growth was observed. However, the high agitation and aeration conditions were detrimental for the growth-associated laccase production constant (αLacc), leading to a very complex optimization of the process. The maximal laccase volumetric activity (1.2 and 3.8U/ml for non-induced and copper-induced cultures, respectively) was observed when the culturing was performed at a low agitation rate (0.9kW/m(3)s) and a high aeration flow rate (0.5vvm). Laccase proteolysis may explain the complex interactions observed between agitation and aeration and the effects of these factors on the laccase volumetric activity observed in the cultures.

  9. The effect of aeration and recirculation on a sand-based hybrid constructed wetland treating low-strength domestic wastewater.

    PubMed

    Zapater-Pereyra, M; Kyomukama, E; Namakula, V; van Bruggen, J J A; Lens, P N L

    2016-08-01

    The Duplex-constructed wetland (CW) is a hybrid system composed of a vertical flow (VF) CW on top of a horizontal flow filter (HFF). Each compartment is designed to play a different role: aerobic treatment in the VF CW due to intermittent feeding and anoxic treatment in the HFF due to saturated conditions. Three Duplex-CWs were used in this study: Control, Aerated and Recirculating. The role of each compartment was tested for pollutant removal and micro-invertebrate abundance. In all systems, the VF CW removed mainly organic matter, solids and NH4(+)-N. Pathogens were removed in both compartments. Likewise, total nitrogen removal occurred in both compartments, only the Recirculating HFF was not able to denitrify the nitrogen due to the slightly more oxic conditions as compared to the other systems. All systems met discharge guidelines for organic matter, but only the Control and Aerated systems met those for total nitrogen. At the applied loading rates, the pollutant removal was not significantly enhanced by the use of aeration and recirculation. Therefore, operation as in the Control system, without aeration or recirculation, is recommended for the tested Duplex-CWs. If artificial aeration will be used in CWs, the support material should be carefully selected to allow a proper air distribution.

  10. Effect of bubble-induced surface turbulence on gas-liquid mass transfer in diffused aeration systems.

    PubMed

    Monteith, H D; Bell, J P; Parker, W J; Melcer, H; Harvey, R T

    2005-01-01

    Models that predict volatilization of organic compounds from wastewater treatment basins may underestimate emission rates if the surfaces are considered as quiescent. In reality, the water surface may be agitated by subsurface aeration, increasing mass transfer across the tank surface air-water interface. This study investigated the effect of turbulence, induced by diffused bubble aeration, on mass transfer at the water surface of a pilot aeration basin. The mass transfer of ammonia from an enclosed headspace over the basin to acidified water was measured when different diffuser types and airflow rates were applied. Oxygen-transfer tests were conducted immediately following each ammonia-transfer test. Increasing airflow rates through fine- and coarse-bubble diffusers had a significant effect on the ammonia mass-transfer rate. Experimental mass-transfer parameters (K(L)a's) for surface volatilization derived with aeration present were up to 48% higher than the K(L)a values for quiescent conditions over the range of conditions tested. No effect of diffuser type on ammonia transfer could be determined. The study results infer an effect on oxygen transfer into the water at the surface and potential transfer of volatile organic compounds, if present, from the water. The results of the ammonia mass-transfer experiments suggest that adjustments to the existing mass transfer correlations for surface volatilization from aeration basins may be in order. Such adjustments will have the greatest effect on predictions for the less volatile compounds, under conditions of low airflow rates.

  11. Nitrogen and carbon removal from synthetic wastewater in a vertical structured-bed reactor under intermittent aeration.

    PubMed

    Moura, Rafael B; Damianovic, Márcia H R Z; Foresti, Eugenio

    2012-05-15

    The removal of nitrogen and organic matter using a single reactor has been a common focus of investigation, and reactors operated in batch mode and under intermittent aeration have attracted special attention. This study aimed to evaluate the application of a new reactor configuration consisting of a fixed-bed reactor that was operated under conditions of continuous feeding and intermittent aeration. The reactor was built using acrylic, with a working volume of 6.1L. The fixed bed used for biomass support was composed of polyurethane foam cylinders vertically oriented inside the reaction zone. The reactor was operated under intermittent aeration (2h aerated and 1h non-aerated) and a recirculation ratio Q(r)/Q=5. Three different operating conditions (Phase I, Phase II, and Phase III) corresponding to hydraulic retention times (HRT) of 12h, 8h, and 10h, respectively, were tested. In Phase I, the system achieved total nitrogen (TN) and chemical oxygen demand (COD) removal efficiencies of 82% and 89%, respectively. At HRTs of 8 h and 10 h, the reactor was unstable with respect to TN removal, and the average resultant removal efficiencies were 49% and 45%, respectively. However, COD removal efficiencies remained high with mean values of 85% and 88% for Phases II and III, respectively. Based on these results, it can be concluded that this new reactor configuration constitutes an alternative method for effective removal of organic matter and nitrogen from wastewater. PMID:22277346

  12. Effects of Aeration of Sawdust Cultivation Bags on Hyphal Growth of Lentinula edodes.

    PubMed

    Lee, Hwa-Yong; Ham, Eun-Ju; Yoo, Young-Jin; Kim, Eui-Sung; Shim, Kyu-Kwang; Kim, Myung-Kon; Koo, Chang-Duck

    2012-09-01

    The effects of aeration through lid filters on the hyphal growth of Lentinula edodes (oak mushroom) in sawdust cultivation bags were investigated. The aeration treatment levels were traditional 27 mm hole cotton plugs, cotton balls and combinations of seven hole sizes × two hole positions (up and under) in the lids covering plastic bags containing 1.4 kg sawdust medium at 63% moisture that had been autoclaved for one hour and inoculated with sawdust spawn of L. edodes strain 921. Aeration treatment effects were measured based on the CO(2) concentration at the 15th wk, as well as the hyphal growth rate and degree of weight loss of bags every 14 days for 15 wk. In bags with traditional cotton plugs, the CO(2) concentration was 3.8 ± 1.3%, daily mean hyphal growth was 2.3 ± 0.6 mm and daily mean weight loss was 0.84 ± 0.26 g. In the bags with 15 mm diameter holes, the CO(2) concentration was 6.0 ± 1.6%, daily hyphal growth was 2.8 ± 0.2 mm and daily weight loss was 0.86 ± 0.4 g. The bags with 15 mm holes had a higher CO(2) concentration and lower water loss than bags with other hole sizes, but the hyphal growth was not significantly different from that of other bags. The weight loss of bags increased proportionally relative to the lid hole sizes. Taken together, these results indicate that traditional cotton plugs are economically efficient, but 15 mm hole lids are the most efficient at maintaining hyphal growth and controlling water loss while allowing CO(2) emissions.

  13. Impact of aeration strategy on CHO cell performance during antibody production.

    PubMed

    Velez-Suberbie, M Lourdes; Tarrant, Richard D R; Tait, Andrew S; Spencer, Daniel I R; Bracewell, Daniel G

    2013-01-01

    Stirred tank bioreactors using suspension adapted mammalian cells are typically used for the production of complex therapeutic proteins. The hydrodynamic conditions experienced by cells within this environment have been shown to directly impact growth, productivity, and product quality and therefore an improved understanding of the cellular response is critical. Here we investigate the sub-lethal effects of different aeration strategies on Chinese hamster ovary cells during monoclonal antibody production. Two gas delivery systems were employed to study the presence and absence of the air-liquid interface: bubbled direct gas sparging and a non-bubbled diffusive silicone membrane system. Additionally, the effect of higher gas flow rate in the sparged bioreactor was examined. Both aeration systems were run using chemically defined media with and without the shear protectant Pluronic F-68 (PF-68). Cells were unable to grow with direct gas sparging without PF-68; however, when a silicone membrane aeration system was implemented growth was comparable to the sparged bioreactor with PF-68, indicating the necessity of shear protectants in the presence of bubbles. The cultures exposed to increased hydrodynamic stress were shown by flow cytometry to have decreased F-actin intensity within the cytoskeleton and enter apoptosis earlier. This indicates that these conditions elicit a sub-lethal physiological change in cells that would not be detected by the at-line assays which are normally implemented during cell culture. These physiological changes only result in a difference in continuous centrifugation performance under high flow rate conditions. Product quality was more strongly affected by culture age than the hydrodynamic conditions tested.

  14. Influence of Aeration and of Pantothenate on Growth Yields of Zymomonas mobilis

    PubMed Central

    Belaïch, Jean-Pierre; Senez, Jacques C.

    1965-01-01

    Belaïch, Jean-Pierre (Centre National de la Recherche Scientifique, Marseille, France), and Jacques C. Senez. Influence of aeration and of pantothenate on growth yields of Zymomonas mobilis. J. Bacteriol. 89:1195–1200. 1965.—The growth yields and rates of Zymomonas mobilis were measured in aerobic and anaerobic cultures on glucose medium containing yeast extract, amino acids, or ammonium chloride as the nitrogen source. In the absence of yeast extract, pantothenate was required. The growth yield and rate of the cultures in synthetic (amino acids) or minimal (NH4Cl) medium supplemented with pantothenate corresponded only to about one-half the “normal” values obtained in the presence of yeast extract, suggesting a situation of energetically uncoupled growth. Attempts to restore normal growth by the addition of various compounds were unsuccessful. Aeration of the cultures resulted in a partial oxidation of ethyl alcohol to acetate, but did not modify the growth yield nor the division time. Both aerobic and anaerobic cells, however, contained cytochrome c and a cytochrome oxidase of the a2 type, which was completely inhibited by 10−4m cyanide. In anaerobically grown cells, an additional cytochrome of the b type was present. The absence of a Pasteur effect suggests that the transfer of electrons by the respiratory chain of Z. mobilis may not be coupled with oxidative phosphorylation. Aeration had no effect on the catalase content of the cells. As shown by C14-glucose incorporation, 2 to 3% of the glucose metabolized was assimilated by the cells in both synthetic and rich complex medium. No intracellular glycogen nor poly-β-hydroxybutyrate was accumulated when growth was limited by nitrogen or by phosphate in the presence of excess glucose. PMID:14292985

  15. Depuration in aerated ponds of citrus processing wastewater with a high concentration of essential oils.

    PubMed

    Zema, Demetrio Antonio; Andiloro, Serafina; Bombino, Giuseppe; Tamburino, Vincenzo; Sidari, Rossana; Caridi, Andrea

    2012-06-01

    Citrus processing wastewater was treated in aerated pilot plants in order to evaluate the following: (a) energy efficiency under different air flow rates and times; and (b) limits of spontaneous microflora in adapting to essential oils. In comparison to permanent air flow, night aeration for 12 hours determined an increase of up to 12% of the monthly removal rate of chemical oxygen demand (COD) and a consequent reduction by 10% of energy consumptions per unit of COD removed from 0.63 to 0.57 kWh/kg(COD). Lowering night aeration from 14 to 7 1/m3/h reduced by only 10% the removal rate of COD; the energy consumption per unit of COD removed (0.32 kWh/kg(COD)) was consequently reduced by more than 40%. Dissolved oxygen was maintained at very low level, rarely exceeding 0.2 ppm, with no bad smell. The consequent high oxygen deficit of 98-99% of saturation induced high oxygen transfer efficiency. The microbial population was characterized mainly by aerobic bacteria; only 5-8% of bacteria were strictly anaerobic. In the deep tank layer under the air diffuser a small amount of sludge settled (0.03-0.04 kg of dry matter per kg of COD removed), containing only 3% of total organic matter detected at the end of the depuration process. The fact that the concentration of essential oils could be progressively increased up to 1400 ppm without noticeably slowing down the biological processes demonstrated the remarkable microbial adaptation. PMID:22856297

  16. Lung Cancer Screening

    MedlinePlus

    ... Cancer Treatment Small Cell Lung Cancer Treatment Lung cancer is the leading cause of cancer death in the United States. Lung cancer is ... non- skin cancer in the United States. Lung cancer is the leading cause of cancer death in men and in women. ...

  17. Interstitial Lung Diseases

    MedlinePlus

    Interstitial lung disease is the name for a large group of diseases that inflame or scar the lungs. The inflammation and scarring make it hard to ... air is responsible for some types of interstitial lung diseases. Specific types include Black lung disease among ...

  18. The lung microbiome after lung transplantation.

    PubMed

    Becker, Julia; Poroyko, Valeriy; Bhorade, Sangeeta

    2014-04-01

    Lung transplantation survival remains significantly impacted by infections and the development of chronic rejection manifesting as bronchiolitis obliterans syndrome (BOS). Traditional microbiologic data has provided insight into the role of infections in BOS. Now, new non-culture-based techniques have been developed to characterize the entire population of microbes resident on the surfaces of the body, also known as the human microbiome. Early studies have identified that lung transplant patients have a different lung microbiome and have demonstrated the important finding that the transplant lung microbiome changes over time. Furthermore, both unique bacterial populations and longitudinal changes in the lung microbiome have now been suggested to play a role in the development of BOS. In the future, this technology will need to be combined with functional assays and assessment of the immune responses in the lung to help further explain the microbiome's role in the failing lung allograft.

  19. Fate of microconstituents in biosolids composted in an aerated silage bag.

    PubMed

    Lozano, Nuria; Andrade, Natasha A; Deng, Di; Torrents, Alba; Rice, Clifford P; McConnell, Laura L; Ramirez, Mark; Millner, Patricia D

    2014-01-01

    Although most composting studies report pathogen concentrations, little is known about the fate of Endocrine Disruptor Chemicals (EDCs) during composting. In this study, a positively aerated polyethylene bag composting system was filled with a mixture of woodchips and limed biosolids from a large Waste Water Treatment Plant (WWTP) to study the removal efficiency of two different groups of EDCs. Two antibacterial compounds, Triclocarban (TCC) and Triclosan (TCS), and a TCS byproduct, Methyltriclosan (MeTCS), as well as seven congeners of flame retardants known as PBDEs (Polybrominated Diphenyl Ethers) were studied during two phases of composting: 1) a thermophilic phase, in which positive mechanical aeration, pushing air into and through the materials matrix, was conducted for 2 months; and 2) a curing and stabilization phase in which no mechanical aeration was provided and the bag was opened to ambient passive aeration to simulate storage conditions for seven months. Our results showed that while TCC concentrations remained constant, TCS degradation took place during both phases. The degradation of TCS was corroborated by the formation of MeTCS in both phases. The TCS concentrations decreased from 18409 ± 1,877 to 11955 ± 288 ng g(-1) dry wt. during the thermophilic phase and declined from 11,955 ± 288 to 7,244 ± 909. ng g(-1) dry wt. by the end of the curing phase. Thus, slightly greater TCS transformation occurred during the second than during the first (35.1 vs. 39.4%). MeTCS concentrations increased from 189.3 ± 8.6 to 364.6 ± 72.5 ng g(-1) dry wt. during the first phase and reached 589.0 ± 94.9 ng g(-1) dry wt. at the end of the second phase. PBDEs concentrations were below quantification limits for all but two of the congeners analyzed (BDE-47 and BDE-99). PBDE concentrations were measured at the end of the first phase only and were comparable to initial concentrations. PMID:24521417

  20. Ex vivo lung perfusion.

    PubMed

    Reeb, Jeremie; Cypel, Marcelo

    2016-03-01

    Lung transplantation is an established life-saving therapy for patients with end-stage lung disease. Unfortunately, greater success in lung transplantation is hindered by a shortage of lung donors and the relatively poor early-, mid-, and long-term outcomes associated with severe primary graft dysfunction. Ex vivo lung perfusion has emerged as a modern preservation technique that allows for a more accurate lung assessment and improvement in lung quality. This review outlines the: (i) rationale behind the method; (ii) techniques and protocols; (iii) Toronto ex vivo lung perfusion method; (iv) devices available; and (v) clinical experience worldwide. We also highlight the potential of ex vivo lung perfusion in leading a new era of lung preservation. PMID:26700566

  1. Temperature dependence of stream aeration coefficients and the effect of water turbulence: a critical review.

    PubMed

    Demars, B O L; Manson, J R

    2013-01-01

    The gas transfer velocity (K(L)) and related gas transfer coefficient (k(2) = K(L)A/V, with A, area and V, volume) at the air-water interface are critical parameters in all gas flux studies such as green house gas emission, whole stream metabolism or industrial processes. So far, there is no theoretical model able to provide accurate estimation of gas transfer in streams. Hence, reaeration is often estimated with empirical equations. The gas transfer velocity need then to be corrected with a temperature coefficient θ = 1.0241. Yet several studies have long reported variation in θ with temperature and 'turbulence' of water (i.e. θ is not a constant). Here we re-investigate thoroughly a key theoretical model (Dobbins model) in detail after discovering important discrepancies. We then compare it with other theoretical models derived from a wide range of hydraulic behaviours (rigid to free continuous surface water, wave and waterfalls with bubbles). The results of the Dobbins model were found to hold, at least theoretically in the light of recent advances in hydraulics, although the more comprehensive results in this study highlighted a higher degree of complexity in θ's behaviour. According to the Dobbins model, the temperature coefficient θ, could vary from 1.005 to 1.042 within a temperature range of 0-35 °C and wide range of gas transfer velocities, i.e. 'turbulence' condition (0.005 < K(L) < 1.28 cm min(-1)). No other theoretical models showed any significant variability in θ with change in 'turbulence', and only modest variability in θ with change in temperature. However, the other theoretical models did not have the same temperature coefficient θ (with 1.000 < θ < 1.056 within 0-35 °C). A model integrating turbulence and bubble mediated gas transfer velocities suggested a lower temperature dependence for bubble (1.013<θ < 1.017) than turbulence (1.023<θ < 1.031) mediated processes. As it stands, the effect of turbulence on the temperature dependence

  2. Temperature dependence of stream aeration coefficients and the effect of water turbulence: a critical review.

    PubMed

    Demars, B O L; Manson, J R

    2013-01-01

    The gas transfer velocity (K(L)) and related gas transfer coefficient (k(2) = K(L)A/V, with A, area and V, volume) at the air-water interface are critical parameters in all gas flux studies such as green house gas emission, whole stream metabolism or industrial processes. So far, there is no theoretical model able to provide accurate estimation of gas transfer in streams. Hence, reaeration is often estimated with empirical equations. The gas transfer velocity need then to be corrected with a temperature coefficient θ = 1.0241. Yet several studies have long reported variation in θ with temperature and 'turbulence' of water (i.e. θ is not a constant). Here we re-investigate thoroughly a key theoretical model (Dobbins model) in detail after discovering important discrepancies. We then compare it with other theoretical models derived from a wide range of hydraulic behaviours (rigid to free continuous surface water, wave and waterfalls with bubbles). The results of the Dobbins model were found to hold, at least theoretically in the light of recent advances in hydraulics, although the more comprehensive results in this study highlighted a higher degree of complexity in θ's behaviour. According to the Dobbins model, the temperature coefficient θ, could vary from 1.005 to 1.042 within a temperature range of 0-35 °C and wide range of gas transfer velocities, i.e. 'turbulence' condition (0.005 < K(L) < 1.28 cm min(-1)). No other theoretical models showed any significant variability in θ with change in 'turbulence', and only modest variability in θ with change in temperature. However, the other theoretical models did not have the same temperature coefficient θ (with 1.000 < θ < 1.056 within 0-35 °C). A model integrating turbulence and bubble mediated gas transfer velocities suggested a lower temperature dependence for bubble (1.013<θ < 1.017) than turbulence (1.023<θ < 1.031) mediated processes. As it stands, the effect of turbulence on the temperature dependence

  3. Epidemiology of Lung Cancer

    PubMed Central

    Ridge, Carole A.; McErlean, Aoife M.; Ginsberg, Michelle S.

    2013-01-01

    Incidence and mortality attributed to lung cancer has risen steadily since the 1930s. Efforts to improve outcomes have not only led to a greater understanding of the etiology of lung cancer, but also the histologic and molecular characteristics of individual lung tumors. This article describes this evolution by discussing the extent of the current lung cancer epidemic including contemporary incidence and mortality trends, the risk factors for development of lung cancer, and details of promising molecular targets for treatment. PMID:24436524

  4. Improving donor lung suitability: from protective strategies to ex-vivo reconditioning.

    PubMed

    Solidoro, Paolo; Schreiber, Annia; Boffini, Massimo; Braido, Fulvio; DI Marco, Fabiano

    2016-06-01

    Lung transplant is a therapeutic option for end stage lung diseases, but only a limited number of lung grafts is considered suitable for transplantation. It has been recently suggested an approach to improve and maximize donor lung suitability, namely ventilation strategies to prevent lung damage and preserve function before transplantation. In potential lung donor patients, the use of lung-protective ventilatory strategies may protect against and at least partially reverse some conditions, such as ventilator-induced lung injury, atelectasis and neurogenic pulmonary edema, resulting in improved donor organ procurement. The novelty recently proposed lies in the integration of ventilatory strategies of previous studies, using an algorithmic approach for the management of potential donors, based on their clinical response and PaO2/FiO2 ratio. This approach could be further improved by using lung ultrasound (LUS) which demonstrated to be more accurate than bedside chest radiography in detecting and distinguishing different degrees of aeration loss, and could be useful in the evaluation of alveolar recruitment following the application of PEEP or after performing any recruitment maneuver. Finally, the close future is the exploration of ex-vivo reconditioning which introduces the exciting concept of both a protective ventilation and a protective perfusion, reducing the risk of ventilation associated damage, and, on the other hand, washing out potential inflammatory cytokines by low volume high oncotic pressure perfusion, managing the risk of edema by capillary leakage. Addressing these challenges will allow more patients with end-stage lung disease access to a lung transplant. PMID:27424500

  5. Molecular diagnosis in lung diseases.

    PubMed

    Calabrese, Fiorella; Lunardi, Francesca; Popper, Helmut

    2015-01-01

    The development of different molecular biology techniques in the past decade has led to an explosion of new research in molecular pathology with consequent important applications to diagnosis, prognosis, and therapeutics, as well as a clearer concept of the disease pathogenesis. Many methods used in molecular pathology are now validated and used in several areas of pathological diagnosis, particularly on infectious and neoplastic diseases. The spectrum of infectious diseases, especially lung infective diseases, is now broadening and modifying, thus the pathologist is increasingly involved in the diagnosis of these pathologies. The precise tissue characterization of lung infections has an important impact on specific therapeutic treatment. Increased knowledge of significant alterations in lung cancer has led today to a better understanding of the pathogenic substrate underlying the development, progression and metastasis of neoplastic processes. Molecular tests are now routinely performed in different lung tumors allowing a more precise patient stratification in terms of prognosis and therapy. This review focuses on molecular pathology of the principal infective lung diseases and tumors.

  6. Linking biofilm growth to fouling and aeration performance of fine-pore diffuser in activated sludge.

    PubMed

    Garrido-Baserba, Manel; Asvapathanagul, Pitiporn; McCarthy, Graham W; Gocke, Thomas E; Olson, Betty H; Park, Hee-Deung; Al-Omari, Ahmed; Murthy, Sudhir; Bott, Charles B; Wett, Bernhard; Smeraldi, Joshua D; Shaw, Andrew R; Rosso, Diego

    2016-03-01

    Aeration is commonly identified as the largest contributor to process energy needs in the treatment of wastewater and therefore garners significant focus in reducing energy use. Fine-pore diffusers are the most common aeration system in municipal wastewater treatment. These diffusers are subject to fouling and scaling, resulting in loss in transfer efficiency as biofilms form and change material properties producing larger bubbles, hindering mass transfer and contributing to increased plant energy costs. This research establishes a direct correlation and apparent mechanistic link between biofilm DNA concentration and reduced aeration efficiency caused by biofilm fouling. Although the connection between biofilm growth and fouling has been implicit in discussions of diffuser fouling for many years, this research provides measured quantitative connection between the extent of biofouling and reduced diffuser efficiency. This was clearly established by studying systematically the deterioration of aeration diffusers efficiency during a 1.5 year period, concurrently with the microbiological study of the biofilm fouling in order to understand the major factors contributing to diffuser fouling. The six different diffuser technologies analyzed in this paper included four different materials which were ethylene-propylene-diene monomer (EPDM), polyurethane, silicone and ceramic. While all diffusers foul eventually, some novel materials exhibited fouling resistance. The material type played a major role in determining the biofilm characteristics (i.e., growth rate, composition, and microbial density) which directly affected the rate and intensity at what the diffusers were fouled, whereas diffuser geometry exerted little influence. Overall, a high correlation between the increase in biofilm DNA and the decrease in αF was evident (CV < 14.0 ± 2.0%). By linking bacterial growth with aeration efficiency, the research was able to show quantitatively the causal connection

  7. Advanced start-up of anaerobic attached film expanded bed reactor by pre-aeration of biofilm carrier.

    PubMed

    Ye, Fen-xia; Chen, Ying-xu; Feng, Xiao-shan

    2005-01-01

    The start-up and performance of the anaerobic attached film expanded bed (AAFEB) reactor with pre-aeration of carrier were investigated. The carriers of the reactors had been aerated for 10 days before they were put into the AAFEB reactors. The results indicated that the reactors advance the start-up by 15 days, and maintain higher efficiency when they were subjected to organic and hydraulic loading shock, but during steady-state operation, the reactors did not show better performance than the control reactors without pre-aeration of carrier. The thicker biofilm and higher biomass concentration of the reactors with pre-aeration were observed during the start-up period, but the difference between two types of reactors tapered with the time course, and at the steady-state operation, the difference between two types of reactors on these two parameters was not obvious. Maximum specific methane or acids production rates, dehydrogenase activity and coenzyme F(420) content were continuously higher than those of the control reactors. After running 30 days, filamentous bacteria dominated in the reactors with pre-aeration, whereas the cocci were predominant species in the control reactors. It was suggested that the action of the biofilm is strongly dependent on the biofilm thickness or the biomass concentration in normal circumstances, but under adverse circumstances, such as organic or hydraulic loading shock, the characteristics and activity of the anaerobic granular sludge play key roles on the reactor performance. These results clearly indicated that pre-aeration of carrier favor to enhance the start-up and performance of AAFEB reactor. PMID:15364089

  8. Crustacean zooplankton in aerated wastewater treatment lagoons as a potential feedstock for biofuel.

    PubMed

    Kring, Stefanie A; Xia, Xiaoyan; Powers, Susan E; Twiss, Michael R

    2013-01-01

    Zooplankton biomass productivity was estimated for two 64,000 m3 (1.7 ha) facultative aerated wastewater treatment lagoons to evaluate potential biodiesel production from zooplankton biomass. Lagoons were monitored bi-weekly during summer 2010. Lipid accumulated by crustacean zooplankton was considered the most efficient means by which to collect lipid produced by phytoplankton owing to the greater ease in the collection of these organisms (>0.153mm) compared with unicellular algae (size <0.06 mm). In terms of biomass, the cladoceran Daphnia and the copepod Cyclops were the dominant zooplankton in these hypereutrophic lagoons, while unicellular chlorophytes dominated the phytoplankton community. Secondary productivity of these lagoons (250 g of dry weight m(-2) yr(-1)) is comparable to the secondary productivity of other sewage lagoons. The potential biodiesel production for one lagoon was estimated to be 0.04 +/- 0.02 L m(-2) yr(-1), which results in a total of 1120 +/- 560 L from two lagoons. This study showed that there are organisms present in wastewater lagoons, besides algae, that can serve as a biofuel feedstock. Additionally, this research expands the current knowledge of facultative aerated wastewater lagoon ecology and waste stream-derived biofuel. Future research should include complete life cycle and economic analyses to determine if harvesting zooplankton from wastewater lagoons is a sustainable endeavour. PMID:24350451

  9. Direct sewage up-concentration by submerged aerated and vibrated membranes.

    PubMed

    Mezohegyi, G; Bilad, M R; Vankelecom, Ivo F J

    2012-08-01

    Membrane filtration is a promising technology for realising the so-called ZeroWasteWater concept, i.e. the wastewater can be up-concentrated and the retentate can sequentially be sent to a bioreactor (e.g., for energy production) while the permeate is aimed for reuse. In the present study, aerated and novel vibrated membrane filtration systems were evaluated as possible techniques for both energy and water recovery through the up-concentration of sewage from a municipal wastewater treatment plant. The lab-scale experiments proved the clear advantage of vibrated membrane filtration over the aerated system, considering both the filtration performance (fouling control) and energy usage. Both microfiltration systems were found efficient in up-concentrating the COD, but not the nitrogen nor the phosphorus. The semi-continuous pilot-scale experiment could not confirm the usefulness of the process which was due to both fast in situ microbial COD degradation and fast particulate COD settling in the feed tank.

  10. Large eddy simulation of dilute bubbly turbulent flows for aerating hydrofoils

    NASA Astrophysics Data System (ADS)

    Hajit, Mohammad; Sotiropoulos, Fotis

    2014-11-01

    We have proposed a formulation for the large eddy simulation of dilute bubbly flows by converting the governing equations to a more loosely-coupled form. This formulation provides an efficient numerical procedure for two-way coupling of bubbly flows at low gas holdups. Subgrid-scale turbulence modeling is based on the dynamic procedure of Germano for the liquid phase and the Jakobson approach for the gas phase. Wall-modeling is implemented using the method of Cabot & Moin. Our approach is employed to simulate flow over aerating hydrofoils at different angles of attack. A structured body-fitted C-grid is employed for domain discretization. Validation of our computational code, for C-grids, is carried out by simulating single-phase flows over a NACA0012 airfoil (20° AOA) with laminar flow and an E387 airfoil (6° AOA) with turbulent flow. Comparisons with available computational and experimental data in terms of time averaged drag coefficient, lift coefficient, separation bubble length, and reattachment point proves the validity of our computational code. The aerating hydrofoil simulation utilizes a NACA0015 hydrofoil, for which experiments were carried out at Saint Anthony Falls Laboratory. Comparisons between computational and experimental datasets show promising results. This work is supported by the U.S. Dept. of Energy and the Hydro Reasearch Foundation.

  11. Effect of auxotrophies on yeast performance in aerated fed-batch reactor

    SciTech Connect

    Landi, Carmine; Paciello, Lucia; Alteriis, Elisabetta de; Brambilla, Luca; Parascandola, Palma

    2011-10-28

    Highlights: Black-Right-Pointing-Pointer The paper contributes to fill the gap existing between the basic and applied research. Black-Right-Pointing-Pointer Mathematical model sheds light on the physiology of auxotrophic yeast strains. Black-Right-Pointing-Pointer Yeast behavior in fed-batch is influenced by biological and environmental determinants. Black-Right-Pointing-Pointer Process optimization would make possible the production of heterologous proteins which are not yet on the market. -- Abstract: A systematic investigation on the effects of auxotrophies on the performance of yeast in aerated fed-batch reactor was carried out. Six isogenic strains from the CEN.PK family of Saccharomyces cerevisiae, one prototroph and five auxotrophs, were grown in aerated fed-batch reactor using the same operative conditions and a proper nutritional supplementation. The performance of the strains, in terms of final biomass decreased with increasing the number of auxotrophies. Auxotrophy for leucine exerted a profound negative effect on the performance of the strains. Accumulation of reactive oxygen species (ROS) in the cells of the strain carrying four auxotrophies and its significant viability loss, were indicative of an oxidative stress response induced by exposure of cells to the environmental conditions. The mathematical model was fundamental to highlight how the carbon flux, depending on the number and type of auxotrophies, was diverted towards the production of increasingly large quantities of energy for maintenance.

  12. On the occurrence of anoxic microniches, denitrification, and sulfate reduction in aerated activated sludge

    SciTech Connect

    Schramm, A.; Santegoeds, C.M.; Nielsen, H.K.; Ploug, H.; Wagner, M.; Pribyl, M.; Wanner, J.; Amann, R.; De Beer, D.

    1999-09-01

    A combination of different methods was applied to investigate the occurrence of anaerobic processes in aerated activated sludge. Microsensor measurements (O{sub 2}, NO{sub 2}{sup {minus}}, NO{sub 3}{sup {minus}}, and H{sub 2}S) were performed on single sludge flocs to detect anoxic niches, nitrate reduction, or sulfate reduction on a microscale. Incubations of activated sludge with {sup 15}NO{sub 3}{sup {minus}} and {sup 35}SO{sub 4}{sup 2{minus}} were used to determine denitrification and sulfate reduction rates on a batch scale. In four of six investigated sludges, no anoxic zones developed during aeration, and consequently denitrification rates were very low. However, in two sludges anoxia in flocs coincided with significant denitrification rates. Sulfate reduction could not be detected in any sludge in either the microsensor or the batch investigation, not even under short-term anoxic conditions. In contrast, the presence of sulfate-reducing bacteria was shown by fluorescence in situ hybridization with 16S rRNA-targeted oligonucleotide probes and by PCR-based detection of genes coding for the dissimilatory sulfite reductase. A possible explanation for the absence of advection, i.e., facilitated by flow through pores and channels. This possibility is suggested by the irregularity of some oxygen profiles and by confocal laser scanning microscopy of the three-dimensional floc structures, which showed that flocs from the two sludges in which anoxic zones were found were apparently denser than flocs from the other sludges.

  13. GHG emissions during the high-rate production of compost using standard and advanced aeration strategies.

    PubMed

    Puyuelo, B; Gea, T; Sánchez, A

    2014-08-01

    In this study, we have evaluated different strategies for the optimization of the aeration during the active thermophilic stage of the composting process of source-selected Organic Fraction of Municipal Solid Waste (or biowaste) using reactors at bench scale (50L). These strategies include: typical cyclic aeration, oxygen feedback controller and a new self-developed controller based on the on-line maximization of the oxygen uptake rate (OUR) during the process. Results highlight differences found in the emission of most representative greenhouse gases (GHG) emitted from composting (methane and nitrous oxide) as well as in gases typically related to composting odor problems (ammonia as typical example). Specifically, the cyclic controller presents emissions that can double that of OUR controller, whereas oxygen feedback controller shows a better performance with respect to the cyclic controller. A new parameter, the respiration index efficiency, is presented to quantitatively evaluate the GHG emissions and, in consequence, the main negative environmental impact of the composting process. Other aspects such as the stability of the compost produced and the consumption of resources are also evaluated for each controller.

  14. Crustacean zooplankton in aerated wastewater treatment lagoons as a potential feedstock for biofuel.

    PubMed

    Kring, Stefanie A; Xia, Xiaoyan; Powers, Susan E; Twiss, Michael R

    2013-01-01

    Zooplankton biomass productivity was estimated for two 64,000 m3 (1.7 ha) facultative aerated wastewater treatment lagoons to evaluate potential biodiesel production from zooplankton biomass. Lagoons were monitored bi-weekly during summer 2010. Lipid accumulated by crustacean zooplankton was considered the most efficient means by which to collect lipid produced by phytoplankton owing to the greater ease in the collection of these organisms (>0.153mm) compared with unicellular algae (size <0.06 mm). In terms of biomass, the cladoceran Daphnia and the copepod Cyclops were the dominant zooplankton in these hypereutrophic lagoons, while unicellular chlorophytes dominated the phytoplankton community. Secondary productivity of these lagoons (250 g of dry weight m(-2) yr(-1)) is comparable to the secondary productivity of other sewage lagoons. The potential biodiesel production for one lagoon was estimated to be 0.04 +/- 0.02 L m(-2) yr(-1), which results in a total of 1120 +/- 560 L from two lagoons. This study showed that there are organisms present in wastewater lagoons, besides algae, that can serve as a biofuel feedstock. Additionally, this research expands the current knowledge of facultative aerated wastewater lagoon ecology and waste stream-derived biofuel. Future research should include complete life cycle and economic analyses to determine if harvesting zooplankton from wastewater lagoons is a sustainable endeavour.

  15. The impact of aeration on the competition between polyphosphate accumulating organisms and glycogen accumulating organisms.

    PubMed

    Carvalheira, Mónica; Oehmen, Adrian; Carvalho, Gilda; Eusébio, Mário; Reis, Maria A M

    2014-12-01

    In wastewater treatment plants (WWTPs), aeration is the major energetic cost, thus its minimisation will improve the cost-effectiveness of the process. This study shows that both the dissolved oxygen (DO) concentration and aerobic hydraulic retention time (HRT) affect the competition between polyphosphate accumulating organisms (PAOs) and glycogen accumulating organisms (GAOs). At low DO levels, Accumulibacter PAOs were shown to have an advantage over Competibacter GAOs, as PAOs had a higher oxygen affinity and thus largely maintained their aerobic activity at low DO levels, while GAO activity decreased. Bioreactor operation at low DO levels was found to increase the PAO fraction of the sludge. Furthermore, an increase in aerobic HRT (at a DO level of 2 mg O2/L), promoted the proliferation of GAOs over PAOs, decreasing the EBPR efficiency. Overall, this study shows that low aeration can be beneficial for EBPR performance through selecting for PAOs over GAOs, which should be incorporated into WWTP models in order to minimise energetic costs and improve WWTP sustainability. PMID:25222333

  16. Analysis of up-flow aerated biological activated carbon filter technology in drinking water treatment.

    PubMed

    Lu, Shaoming; Liu, Jincui; Li, Shaowen; Biney, Elizabeth

    2013-01-01

    Problems have been found in the traditional post-positioned down-flow biological activated carbon filter (DBACF), such as microorganism leakage and low biodegradability. A pilot test was carried out to place a BACF between the sediment tank and the sand filter; a new technology of dual media up-flow aerated biological activated carbon filter (UBACF) was developed. Results showed that in terms of the new process, the up-flow mode was better than the down-flow. Compared with the DBACF, the problem of microorganism leakage could be well resolved with the UBACF process by adding disinfectant before the sand filtration, and a similar adsorption effect could be obtained. For the tested raw water, the COD(Mn) and NH3-N removal rate was 54.6% and 85.0%, respectively, similar to the waterworks with the DBACF process. The UBACF greatly enhanced oxygen supply capability and mass transfer rate via aeration, and the NH3-N removal ability was significantly improved from 1.5 mg/L to more than 3 mg/L. Influent to the UBACF with higher turbidity could be coped with through the primary filtration of the ceramisite layer combined with fluid-bed technology, which gave the carbon bed a low-turbidity environment of less than 1.0 NTU. The backwashing parameters and carbon abrasion rate of the two processes were almost the same.

  17. Removal of human enteric viruses and indicator microorganisms from domestic wastewater by aerated lagoons.

    PubMed

    Locas, Annie; Martinez, Veronica; Payment, Pierre

    2010-02-01

    Aerated lagoons offer a low-cost and simple approach to treating domestic wastewater in small municipalities. The objective of the current study was to evaluate, for each cell in the lagoons, the removal of indicator microorganisms and human enteric viruses under warm (summer) and cold (early spring) conditions. The two sites are located in southwest Quebec, Canada. Samples were assayed for thermotolerant coliforms, enterococci, Clostridium perfringens, somatic and male-specific coliphages, and culturable human enteric viruses (HEV). The results show higher removal under warm ambient conditions for all microorganisms. Thermotolerant coliforms and enterococci were removed to a greater extent than C. perfringens and HEV. HEV removal was only observed in warm ambient conditions. The removal of coliphages was different from the observed removal of HEV. The use of coliphages as surrogates for HEV has been proposed, but this does not seem appropriate for aerated lagoons, as the removal of coliphages overestimates the removal of HEV. Given the low observed removal of HEV during this study, the effluents remain a significant source of pathogens that can affect drinking water treatment plants drawing their raw water from receiving streams. Ultraviolet disinfection of treated wastewater effluent is a possible solution.

  18. Treatment of landfill leachate-impacted groundwater using cascade aeration and constructed wetlands

    SciTech Connect

    Loer, J.; O`Flanagan, B.; Fellows, W.

    1995-12-31

    At an unlined municipal solid waste landfill, heavy metal and toxic organic compounds present in leachate have impacted groundwater, necessitating extraction and treatment of the contaminated groundwater. A remedial design relying on a natural systems engineering approach will take advantage of existing contours (gravity flow) and surroundings (wetlands), and will limit energy inputs and eliminate chemical inputs. Impacted groundwater will be extracted, and aerated via a cascade constructed of polypropylene sheets fabricated into {open_quotes}step{close_quotes} sections and set into a side slope of the landfill. Volatilization of organics and oxidation of iron and heavy metals to insoluble compounds will occur during cascading and will continue within a sedimentation basin where settling of iron precipitates will induce co-settling of heavy metal precipitates. Following the sedimentation basin, a constructed wetland containing both aerobic zones and anaerobic zones will provide additional treatment of remaining solids and heavy metals, before surface discharge. Use of a natural systems approach significantly reduces operating costs compared to a mechanical-aeration, chemical-precipitation system, and is more aesthetically pleasing and suited to the remote locale. The system is under construction and seasonal operation will begin in spring 1996.

  19. Biological iron oxidation by Gallionella spp. in drinking water production under fully aerated conditions.

    PubMed

    de Vet, W W J M; Dinkla, I J T; Rietveld, L C; van Loosdrecht, M C M

    2011-11-01

    Iron oxidation under neutral conditions (pH 6.5-8) may be a homo- or heterogeneous chemically- or a biologically-mediated process. The chemical oxidation is supposed to outpace the biological process under slightly alkaline conditions (pH 7-8). The iron oxidation kinetics and growth of Gallionella spp. - obligatory chemolithotrophic iron oxidizers - were assessed in natural, organic carbon-containing water, in continuous lab-scale reactors and full-scale groundwater trickling filters in the Netherlands. From Gallionella cell numbers determined by qPCR, balances were made for all systems. The homogeneous chemical iron oxidation occurred in accordance with the literature, but was retarded by a low water temperature (13 °C). The contribution of the heterogeneous chemical oxidation was, despite the presence of freshly formed iron oxyhydroxides, much lower than in previous studies in ultrapure water. This could be caused by the adsorption of natural organic matter (NOM) on the iron oxide surfaces. In the oxygen-saturated natural water with a pH ranging from 6.5 to 7.7, Gallionella spp. grew uninhibited and biological iron oxidation was an important, and probably the dominant, process. Gallionella growth was not even inhibited in a full-scale filter after plate aeration. From this we conclude that Gallionella spp. can grow under neutral pH and fully aerated conditions when the chemical iron oxidation is retarded by low water temperature and inhibition of the autocatalytic iron oxidation.

  20. Interstitial lung disease - adults - discharge

    MedlinePlus

    Diffuse parenchymal lung disease - discharge; Alveolitis - discharge; Idiopathic pulmonary pneumonitis - discharge; IPP - discharge; Chronic interstitial lung - discharge; Chronic respiratory interstitial lung - ...

  1. Methodology, data collection, and data analysis for determination of water-mixing patterns induced by aerators and mixers

    USGS Publications Warehouse

    Johnson, Gary P.; Hornewer, N.J.; Robertson, D.M.; Olson, D.T.; Gioja, Josh

    2000-01-01

    The U.S. Geological Survey collected and analyzed data to describe mixing patterns induced by aerators and mixers to aid in the calibration and verification of a three-dimensional hydrodynamic model. During September 1995, three-dimensional water-velocity profiles were collected during the operation of fine-bubble and coarse-bubble aerators in a test tank at the U.S. Army Corps of Engineers Waterways Experiment Station. Three-dimensional water velocity, water-temperature, pH, dissolved oxygen concentration, and specific conductivity profiles were collected during operation of a coarse-bubble aerator in a reservoir in Schaumburg, Illinois, during summer 1996 and summer 1997, during strongly stratified and weakly stratified conditions. The effects of a submersible mixer alone and in combination with coarse-bubble aerators and a surface mixer alone also were investigated during summer 1997. The mixing patterns induced by the operation of aerators, submersible mixers, and surface mixers were described and compared with mixing patterns predicted by model simulations. Bubble-plume characteristics during tests in strongly stratified and weakly stratified conditions in the reservoir were documented and compared with characteristics simulated by different models. Lemckert and Imberger?s model simulates an entrainment rate similar to the rate measured during a test in the reservoir under strongly stratified conditions, whereas Schladow?s one-dimensional model appears to underestimate the total entrainment rate by about 50 percent. Schladow?s model was accurate during weak stratification but underestimated the radius of the plume during strong stratification. For 5 days during daylight hours, water temperature profiles were collected continuously during the operation of four aerators. Water temperatures in the reservoir were significantly affected by the operation of the aeration system. These changes were compared to simulations from a one-dimensional Dynamic Lake Model (DLM

  2. [Lung cancer in elderly patients: lung cancer and lung function].

    PubMed

    Tanita, Tatsuo

    2005-07-01

    The incidence of bronchogenic carcinoma is increasing as life expectancy rises. With increase in the aged population in Japan, the number of patients suffering from lung cancer and candidates for lung resections are increasing. In this paper, the author lists up indispensable procedures for diagnosis, namely, lung function tests, unilateral pulmonary arterial occlusion test and exercise tolerance test. The cut-offs for identifying candidates for elderly patients for lung resections can be applied the same cut-offs for younger patients. Also the author indicates the importance of postoperative management for lung lobe resections. In order to prevent postoperative problems such as congestive heart failure that might be a fetal complication, the most useful check values after the lung surgery for elderly patients are rate of transfusion and urine volume. In conclusion, when elderly patients assert their rights to undergo lung surgery, we, the thoracic surgeons, should reply their requests under the equal quality of safe surgery as that for younger patients. Besides, it is desirable that even elderly patients, over 80 years old, who undergo lung surgery should guarantee their quality of daily life after surgery.

  3. Lung cancer among Navajo uranium miners

    SciTech Connect

    Gottlieb, L.S.; Husen, L.A.

    1982-04-01

    Lung cancer has been a rare disease among the Indians of the southwestern United States. However, the advent of uranium mining in the area has been associated with an increased incidence of lung cancer among Navajo uranium miners. This study centers on Navajo men with lung cancer who were admitted to the hospital from February 1965 to May 1979. Of a total of 17 patients with lung cancer, 16 were uranium miners, and one was a nonminer. The mean value of cumulative radon exposure for this group was 1139.5 working level months (WLMs). The predominant cancer type was the small cell undifferentiated category (62.5 percent). The low frequency of cigarette smoking in this group supports the view that radiation is the primary cause of lung cancer among uranium miners and that cigarette smoking acts as a promoting agent.

  4. Epidemiology of Lung Cancer

    PubMed Central

    Brock, Malcolm V.; Ford, Jean G.; Samet, Jonathan M.; Spivack, Simon D.

    2013-01-01

    Background: Ever since a lung cancer epidemic emerged in the mid-1900s, the epidemiology of lung cancer has been intensively investigated to characterize its causes and patterns of occurrence. This report summarizes the key findings of this research. Methods: A detailed literature search provided the basis for a narrative review, identifying and summarizing key reports on population patterns and factors that affect lung cancer risk. Results: Established environmental risk factors for lung cancer include smoking cigarettes and other tobacco products and exposure to secondhand tobacco smoke, occupational lung carcinogens, radiation, and indoor and outdoor air pollution. Cigarette smoking is the predominant cause of lung cancer and the leading worldwide cause of cancer death. Smoking prevalence in developing nations has increased, starting new lung cancer epidemics in these nations. A positive family history and acquired lung disease are examples of host factors that are clinically useful risk indicators. Risk prediction models based on lung cancer risk factors have been developed, but further refinement is needed to provide clinically useful risk stratification. Promising biomarkers of lung cancer risk and early detection have been identified, but none are ready for broad clinical application. Conclusions: Almost all lung cancer deaths are caused by cigarette smoking, underscoring the need for ongoing efforts at tobacco control throughout the world. Further research is needed into the reasons underlying lung cancer disparities, the causes of lung cancer in never smokers, the potential role of HIV in lung carcinogenesis, and the development of biomarkers. PMID:23649439

  5. Evaluation of air sparging and vadose zone aeration for remediation of iron and manganese-impacted groundwater at a closed municipal landfill.

    PubMed

    Pleasant, Saraya; O'Donnell, Amanda; Powell, Jon; Jain, Pradeep; Townsend, Timothy

    2014-07-01

    High concentrations of iron (Fe(II)) and manganese (Mn(II)) reductively dissolved from soil minerals have been detected in groundwater monitoring wells near many municipal solid waste landfills. Air sparging and vadose zone aeration (VZA) were evaluated as remedial approaches at a closed, unlined municipal solid waste landfill in Florida, USA. The goal of aeration was to oxidize Fe and Mn to their respective immobile forms. VZA and shallow air sparging using a partially submerged well screen were employed with limited success (Phase 1); decreases in dissolved iron were observed in three of nine monitoring wells during shallow air sparging and in two of 17 wells at VZA locations. During Phase 2, where deeper air sparging was employed, dissolved iron levels decreased in a significantly greater number of monitoring wells surrounding injection points, however no radial pattern was observed. Additionally, in wells affected positively by air sparging (mean total iron (FeTOT) <4.2mg/L, after commencement of air sparging), rising manganese concentrations were observed, indicating that the redox potential of the groundwater moved from an iron-reducing to a manganese-reducing environment. The mean FeTOT concentration observed in affected monitoring wells throughout the study was 1.40 mg/L compared to a background of 15.38 mg/L, while the mean Mn concentration was 0.60 mg/L compared to a background level of 0.27 mg/L. Reference wells located beyond the influence of air sparging areas showed little variation in FeTOT and Mn, indicating the observed effects were the result of air injection activities at study locations and not a natural phenomenon. Air sparging was found effective in intercepting plumes of dissolved Fe surrounding municipal landfills, but the effect on dissolved Mn was contrary to the desired outcome of decreased Mn groundwater concentrations.

  6. Atmospheric pollution and lung cancer.

    PubMed Central

    Doll, R

    1978-01-01

    Lung cancer is consistently more common in urban areas than in rural. The excess cannot be accounted for by specific occupational hazards but some of it might be due to the presence of carcinogens in urban air. The excess cannot be wholly due to such agents, because the excess in nonsmokers is small and variable. Cigarette consumption has also been greater in urban areas, but it is difficult to estimate how much of the excess it can account for. Occupational studies confirm that pollutants present in town air are capable of causing lung cancer in man and suggest that the pollutants and cigarette smoke act synergistically. The trends in the mortality from lung cancer in young and middle-aged men in England and Wales provide uncertain evidence but support the belief that atmospheric pollution has contributed to the production of the disease. In the absence of cigarette smoking, the combined effect of all atmospheric carcinogens is not responsible for more than about 5 cases of lung cancer per 100,000 persons per year in European populations. PMID:648488

  7. Epidemiology of Lung Cancer.

    PubMed

    Mao, Yousheng; Yang, Ding; He, Jie; Krasna, Mark J

    2016-07-01

    Lung cancer has been transformed from a rare disease into a global problem and public health issue. The etiologic factors of lung cancer become more complex along with industrialization, urbanization, and environmental pollution around the world. Currently, the control of lung cancer has attracted worldwide attention. Studies on the epidemiologic characteristics of lung cancer and its relative risk factors have played an important role in the tertiary prevention of lung cancer and in exploring new ways of diagnosis and treatment. This article reviews the current evolution of the epidemiology of lung cancer. PMID:27261907

  8. On the Pathogenesis of Acute Exacerbations of Mucoobstructive Lung Diseases.

    PubMed

    Boucher, Richard C

    2015-11-01

    Mucoobstructive lung diseases have highlighted the importance of a proper description of the normal mucus clearance system. A useful description of the normal mucus clearance apparatus requires the presence of two gels on the airway surface (i.e., a mucus layer gel and a periciliary gel). Importantly, most mucoobstructive lung diseases are distributed heterogeneously in the lung, and exacerbations may reflect spread of the disease to previously normal areas. The spread may reflect disturbances in the balance of water between the two gel layers, producing heterogeneous mucus adhesion and infection within the lung. Ultimately, spread can produce losses of lung function that may be associated with acute exacerbation frequency.

  9. On the Pathogenesis of Acute Exacerbations of Mucoobstructive Lung Diseases

    PubMed Central

    2015-01-01

    Mucoobstructive lung diseases have highlighted the importance of a proper description of the normal mucus clearance system. A useful description of the normal mucus clearance apparatus requires the presence of two gels on the airway surface (i.e., a mucus layer gel and a periciliary gel). Importantly, most mucoobstructive lung diseases are distributed heterogeneously in the lung, and exacerbations may reflect spread of the disease to previously normal areas. The spread may reflect disturbances in the balance of water between the two gel layers, producing heterogeneous mucus adhesion and infection within the lung. Ultimately, spread can produce losses of lung function that may be associated with acute exacerbation frequency. PMID:26595733

  10. Study on Influence Caused by Design and Operation Factors of Contact Aeration Tank on Effluent ATU-BOD·N-BOD Concentrations from Sedimentation Tank in Rural Sewerage Facilities with Biofilm Processes

    NASA Astrophysics Data System (ADS)

    Nakano, Takuji

    The design and operation factors on the effluent ATU-BOD·N-BOD concentrations in sedimentation tank were investigated by using observed data in the rural sewerage facilities with biofilm processes. It was found that the effluent N-BOD accounted for approximate 50 percent of the effluent BOD concentration in sedimentation tank because of the effluent ATU-BOD decrease(about 70 percent) and the effluent N-BOD increase (about 4 times) by treatment processes of contact aeration tank. It was recognized that the effluent ATU-BOD concentration in sedimentation tank was influenced by the design and operation factors such as influent ATU-BOD concentration, specific surface area of contact filter for fixed bed submerged filter, and average DO in contact aeration tank. The effluent ATU-BOD concentration in sedimentation tank was assumed to be governed by first-order function with complete-mix system of biological treatment processes. The effluent ATU-BOD concentration in sedimentation tank was found to be predicted by the empirical formula of hydraulic retention time, influent ATU-BOD concentration, specific surface area of contact filter for fixed bed submerged filter, and average DO in contact aeration tank. It was recognized that the peak effluent N-BOD concentration in sedimentation tank occurred in the around 10∼15 hour of hydraulic retention time under the influence of biological nitrification reaction and nitrogenous compound. The effluent N-BOD concentration in sedimentation tank was also influenced by the effluent SS concentration in sedimentation tank.

  11. Strategies for Whole Lung Tissue Engineering

    PubMed Central

    Calle, Elizabeth A.; Ghaedi, Mahboobe; Sundaram, Sumati; Sivarapatna, Amogh; Tseng, Michelle K.

    2014-01-01

    Recent work has demonstrated the feasibility of using decellularized lung extracellular matrix scaffolds to support the engineering of functional lung tissue in vitro. Rendered acellular through the use of detergents and other reagents, the scaffolds are mounted in organ-specific bioreactors where cells in the scaffold are provided with nutrients and appropriate mechanical stimuli such as ventilation and perfusion. Though initial studies are encouraging, a great deal remains to be done to advance the field and transition from rodent lungs to whole human tissue engineered lungs. To do so, a variety of hurdles must be overcome. In particular, a reliable source of human-sized scaffolds, as well as a method of terminal sterilization of scaffolds, must be identified. Continued research in lung cell and developmental biology will hopefully help identify the number and types of cells that will be required to regenerate functional lung tissue. Finally, bioreactor designs must be improved in order to provide more precise ventilation stimuli and vascular perfusion in order to avoid injury to or death of the cells cultivated within the scaffold. Ultimately, the success of efforts to engineer a functional lung in vitro will critically depend on the ability to create a fully endothelialized vascular network that provides sufficient barrier function and alveolar-capillary surface area to exchange gas at rates compatible with healthy lung function. PMID:24691527

  12. Hypoxia and the Lung: Beyond Hypoxic Vasoconstriction

    PubMed Central

    Nicolls, Mark R.; Voelkel, Norbert F.

    2011-01-01

    This article extends the influence and effects of hypoxia on the lung beyond vasoconstriction and regional blood flow control. Clearly, hypoxia, via the transcription factor hypoxia-inducible factor (HIF)-1α, induces a large number of genes encoding proteins, which control cellular metabolism and growth and also participate in inflammation. Hypoxia, likely via vascular endothelial growth factor (VEGF), recruits bone marrow precursor cells to the lung and affects the behavior of immune cells. How hypoxia shapes immune responses through VEGF and its receptors on mast cells, eosinophils, and dendritic cells and through lung endothelial cell/lymphocyte interactions will be a productive area for future research. PMID:17511589

  13. Immune checkpoint blockade in lung cancer.

    PubMed

    Somasundaram, Aswin; Socinski, Mark A; Villaruz, Liza C

    2016-08-01

    Immunotherapy has revolutionized the therapeutic landscape of advanced lung cancer. The adaptive immune system has developed a sophisticated method of tumor growth control, but T-cell activation is regulated by various checkpoints. Blockade of the immune checkpoints with therapies targeting the PD-1 pathway, such as nivolumab and pembrolizumab, has been validated as a therapeutic approach in non-small cell lung cancer. Newer therapies and novel combinations are also being evaluated, and the use of biomarkers in conjunction with these drugs is an area of active investigation. This review summarizes the current evidence for the efficacy and safety of the above approaches in the treatment of lung cancer. PMID:27585231

  14. Isolated lung perfusion.

    PubMed

    Cypel, Marcelo; Keshavjee, Shaf

    2012-01-01

    Isolated lung perfusion (ILP) has been historically used as a method to study basic lung physiologic concepts using animal models. More recently, ILP has been applied in lung transplantation and thoracic oncology. In lung transplantation, ILP has been used to assess physiological integrity of donor lungs after the organ is removed from the donor. This procedure is called Ex vivo Lung Perfusion (EVLP), and it has also been proposed as a method for active treatment and repair of injured unsuitable donor organs ex vivo. In oncology, ILP is an attractive method to deliver high dose chemotherapy to treat pulmonary metastatic disease. Since the lung vasculature is isolated in vivo, this technique is called in vivo lung perfusion (IVLP). This review will focus on the rationale, technical aspects, experimental and clinical experience of EVLP and IVLP. A perspective on the future use of these techniques is described. PMID:22202033

  15. Ex vivo lung perfusion.

    PubMed

    Machuca, Tiago N; Cypel, Marcelo

    2014-08-01

    Lung transplantation (LTx) is an established treatment option for eligible patients with end-stage lung disease. Nevertheless, the imbalance between suitable donor lungs available and the increasing number of patients considered for LTx reflects in considerable waitlist mortality. Among potential alternatives to address this issue, ex vivo lung perfusion (EVLP) has emerged as a modern preservation technique that allows for more accurate lung assessment and also improvement of lung function. Its application in high-risk donor lungs has been successful and resulted in safe expansion of the donor pool. This article will: (I) review the technical details of EVLP; (II) the rationale behind the method; (III) report the worldwide clinical experience with the EVLP, including the Toronto technique and others; (IV) finally, discuss the growing literature on EVLP application for donation after cardiac death (DCD) lungs. PMID:25132972

  16. Lung Diseases and Conditions

    MedlinePlus

    ... Share this page from the NHLBI on Twitter. Lung Diseases and Conditions Breathing is a complex process. ... your bronchial tubes ( bronchitis ) or deep in your lungs ( pneumonia ). These infections cause a buildup of mucus ...

  17. Lung needle biopsy

    MedlinePlus

    ... not improve, a chest tube is inserted to expand your lung. In rare cases, pneumothorax can be ... Philadelphia, PA: Elsevier Saunders; 2011:chap 197. Silvestri GA, Jett JR. Clinical aspects of lung cancer. In: ...

  18. American Lung Association

    MedlinePlus

    ... Washington DC West Virginia Wisconsin Wyoming November Is Lung Cancer Awareness Month If you or someone you ... RESEARCH Our vision is a world FREE OF LUNG DISEASE Make Each Breath Count: Learn, Engage, Act! ...

  19. Ex vivo lung perfusion

    PubMed Central

    Machuca, Tiago N.

    2014-01-01

    Lung transplantation (LTx) is an established treatment option for eligible patients with end-stage lung disease. Nevertheless, the imbalance between suitable donor lungs available and the increasing number of patients considered for LTx reflects in considerable waitlist mortality. Among potential alternatives to address this issue, ex vivo lung perfusion (EVLP) has emerged as a modern preservation technique that allows for more accurate lung assessment and also improvement of lung function. Its application in high-risk donor lungs has been successful and resulted in safe expansion of the donor pool. This article will: (I) review the technical details of EVLP; (II) the rationale behind the method; (III) report the worldwide clinical experience with the EVLP, including the Toronto technique and others; (IV) finally, discuss the growing literature on EVLP application for donation after cardiac death (DCD) lungs. PMID:25132972

  20. Effects of subsurface aeration and trinexapac-ethyl application on soil microbial communities in a creeping bentgrass putting green

    USGS Publications Warehouse

    Feng, Y.; Stoeckel, D.M.; Van Santen, E.; Walker, R.H.

    2002-01-01

    The sensitivity of creeping bentgrass (Agrostis palustris Huds.) to the extreme heat found in the southeastern United States has led to the development of new greens-management methods. The purpose of this study was to examine the effects of subsurface aeration and growth regulator applications on soil microbial communities and mycorrhizal colonization rates in a creeping bentgrass putting green. Two cultivars (Crenshaw and Penncross), a growth regulator (trinexapacethyl), and subsurface aeration were evaluated in cool and warm seasons. Total bacterial counts were higher in whole (unsieved) soils than in sieved soils, indicating a richer rhizosphere soil environment. Mycorrhizal infection rates were higher in trinexapac-ethyl (TE) treated plants. High levels of hyphal colonization and relatively low arbuscule and vesicle occurrence were observed. Principal components analysis of whole-soil fatty acid methyl ester (FAME) profiles indicated that warm-season microbial populations in whole and sieved soils had similar constituents, but the populations differed in the cool season. FAME profiles did not indicate that subsurface aeration and TE application affected soil microbial community structure. This is the first reported study investigating the influences of subsurface aeration and TE application on soil microorganisms in a turfgrass putting green soil.

  1. Effect of aeration rate, moisture content and composting period on availability of copper and lead during pig manure composting.

    PubMed

    Shen, Yujun; Zhao, Lixin; Meng, Haibo; Hou, Yueqing; Zhou, Haibin; Wang, Fei; Cheng, Hongsheng; Liu, Hongbin

    2016-06-01

    Pollution by heavy metals, such as copper and lead, has become a limiting factor for the land application of faecal manures, such as pig manure. This study was conducted to investigate the influence of composting process parameters, including aeration rate, moisture content and composting period, on the distribution of heavy metal species during composting, and to select an optimal parameter for copper and lead inactivation. Results showed that the distribution ratios of exchangeable fractions of copper and lead had a bigger decrease under conditions of aeration rate, 0.1 m(3) min(-1) m(-3), an initial moisture content of 65% and composting period of 50 days. Suboptimal composting process conditions could lead to increased availability of heavy metals. Statistical analysis indicated that the aeration rate was the main factor affecting copper and lead inactivation, while the effects of moisture content and composting period were not significant. The rates of reduction of copper-exchangeable fractions and lead-exchangeable fractions were positively correlated with increased pH. The optimal parameters for reducing heavy metal bioavailability during pig manure composting were aeration rate, 0.1 m(3) min(-1) m(-3), initial moisture content, 65%, and composting period, 20 days. PMID:27067429

  2. Selective strategies for antibiotic fermentation, Part II: Effect of aeration on streptomycin production by Streptomyces griseus JB-19.

    PubMed

    Maladkar, N K

    1991-01-01

    The effect of higher aerated fermentation medium which enhanced streptomycin production by Streptomyces griseus JB-19 was found mainly related to the changes in dextrose consumption, inorganic phosphate utilisation and ammonia nitrogen accumulation under optimal and suboptimal supply of soluble vegetative protein.

  3. Effect of aeration on stabilization of organic solid waste and microbial population dynamics in lab-scale landfill bioreactors.

    PubMed

    Sang, Nguyen Nhu; Soda, Satoshi; Sei, Kazunari; Ike, Michihiko

    2008-11-01

    This study investigated microbial population dynamics and performance in lab-scale conventional, anaerobic, and aerobic landfill bioreactors specialized for high-organic wastes. Each reactor (2.35 l) was loaded with 1.5 kg of organic solid waste made of sludge cake, dry dog food, and wood chips. The conventional reactor was operated without leachate recirculation and aeration, but the other reactors used leachate recirculation at 200 ml/d and without aeration (anaerobic bioreactor) or with aeration at 2 l/min (aerobic bioreactor). The respective final waste volumes on day 138 of the conventional, anaerobic, and aerobic reactors were approximately 75%, 65%, and 60% of the initial volumes. Leachate recirculation in the anaerobic bioreactor accelerated biochemical reactions and promoted methane production. However, leachate from the anaerobic bioreactor showed TOC and NH(4)(+)-N concentrations that were as high as those of the conventional reactor. Aeration lowered leachate production and methane concentration and decreased organic matter in solid waste and leachate. Furthermore, the MPN value of amoA gene reached 10(5) MPN-copies/g-dry in the aerobic bioreactor, where nitrogen was removed from organic solid waste and leachate. During the first 72 d, the aerobic bioreactor's MPN value of fungal 18S rDNA was the highest among reactors, but it decreased gradually. All reactors showed similar MPN values of eubacterial 16S rDNA, nirS, and nirK. PMID:19111637

  4. Development and on-site field testing of the power-tube airlift aerator and chances for commercialization

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Aeration of ponds when dissolved oxygen (DO) concentrations are low is the principal management tool that allows for higher feeding rates, increased production, and decreased cost per unit fish produced. Recent research conducted at the USDA-ARS Warmwater Aquaculture Research Unit has shown that fee...

  5. Effect of aeration rate, moisture content and composting period on availability of copper and lead during pig manure composting.

    PubMed

    Shen, Yujun; Zhao, Lixin; Meng, Haibo; Hou, Yueqing; Zhou, Haibin; Wang, Fei; Cheng, Hongsheng; Liu, Hongbin

    2016-06-01

    Pollution by heavy metals, such as copper and lead, has become a limiting factor for the land application of faecal manures, such as pig manure. This study was conducted to investigate the influence of composting process parameters, including aeration rate, moisture content and composting period, on the distribution of heavy metal species during composting, and to select an optimal parameter for copper and lead inactivation. Results showed that the distribution ratios of exchangeable fractions of copper and lead had a bigger decrease under conditions of aeration rate, 0.1 m(3) min(-1) m(-3), an initial moisture content of 65% and composting period of 50 days. Suboptimal composting process conditions could lead to increased availability of heavy metals. Statistical analysis indicated that the aeration rate was the main factor affecting copper and lead inactivation, while the effects of moisture content and composting period were not significant. The rates of reduction of copper-exchangeable fractions and lead-exchangeable fractions were positively correlated with increased pH. The optimal parameters for reducing heavy metal bioavailability during pig manure composting were aeration rate, 0.1 m(3) min(-1) m(-3), initial moisture content, 65%, and composting period, 20 days.

  6. Enhanced recovery of ammonia from swine manure anaerobic digester effluent using gas-permeable membranes and aeration

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Atmospheric ammonia pollution from livestock wastes can be reduced using gas-permeable membrane technology by converting ammonia contained in the manure into ammonium salt for use in fertilizers. In this study, gas-permeable membrane technology was enhanced using aeration combined with nitrificatio...

  7. Enhanced phosphorus removal from sewage in mesocosm-scale constructed wetland using zeolite as medium and artificial aeration.

    PubMed

    Vera, I; Araya, F; Andrés, E; Sáez, K; Vidal, G

    2014-08-01

    Phosphorus (P) contained in sewage maybe removed by mesocosm-scale constructed wetlands (MCW), although removal efficiency is only between 20% and 60%. P removal can be enhanced by increasing wetland adsorption capacity using special media, like natural zeolite, operating under aerobic conditions (oxidation-reduction potential (ORP) above +300 mV). The objective of this study was to evaluate P removal in sewage treated by MCW with artificial aeration and natural zeolite as support medium for the plants. The study compared two parallel lines of MCW: gravel and zeolite. Each line consisted in two MCW in series, where the first MCW of each line has artificial aeration. Additionally, four aeration strategies were evaluated. During the operation, the following parameters were measured in each MCW: pH, temperature, dissolved oxygen and ORP. Phosphate (PO4(-3) - P) and chemical oxygen demand (COD), five-day biological oxygen demand (BOD5), total suspended solids (TSS) and ammonium. (NH4(+) - N) were evaluated in influents and effluents. Plant growth (biomass) and proximate analysis for P content into Schoenoplectus californicus were also performed. The results showed that PO4(-3) - P removal efficiency was 70% in the zeolite medium, presenting significant differences (p < .05) with the results obtained by the gravel medium. Additionally, aeration was found to have a significant effect (p < .05) only in the gravel medium with an increase in up to 30% for PO43 - P removal. Thus, S. californicus contributed to 10-20% of P removal efficiency.

  8. Framework for Energy Neutral Treatment for the 21st Century Through Energy Efficient Aeration (WERF Report INFR2R12)

    EPA Science Inventory

    Aeration is commonly identified as the most significant energy use in the treatment of wastewater and therefore garners significant focus in reducing energy use in the ultimate aspirational goal of achieving net energy neutrality for water resource recovery. This research establi...

  9. Application of airlift bioreactor for the cultivation of aerobic oleaginous yeast Rhodotorula glutinis with different aeration rates.

    PubMed

    Yen, Hong-Wei; Liu, Yi Xian

    2014-08-01

    The high cost of microbial oils produced from oleaginous microorganisms is the major obstacle to commercial production. In this study, the operation of an airlift bioreactor is examined for the cultivation of oleaginous yeast-Rhodotorula glutinis, due to the low process cost. The results suggest that the use of a high aeration rate could enhance cell growth. The maximum biomass concentration of 25.40 g/L was observed in the batch with a 2.0 vvm aeration rate. In addition, a higher aeration rate of 2.5 vvm could achieve the maximum growth rate of 0.46 g/L h, about twice the 0.22 g/L h obtained in an agitation tank. However, an increase in tank pressure instead of the aeration rate did not enhance cell growth. The operation of airlift bioreactor described in this work has the advantages of simple operation and low energy consumption, thus making it suitable for the accumulation of microbial oils.

  10. Removal of COD and nitrogen from animal food plant wastewater in an intermittently-aerated structured-bed reactor.

    PubMed

    Wosiack, Priscila Arcoverde; Lopes, Deize Dias; Rissato Zamariolli Damianovic, Márcia Helena; Foresti, Eugenio; Granato, Daniel; Barana, Ana Cláudia

    2015-05-01

    This study evaluated the performance of a continuous flow structured-bed reactor in the simultaneous removal of total nitrogen (TN) and chemical oxygen demand (COD) in the effluent from an animal food plant. The reactor had an intermittent aeration system; hydraulic retention time (HRT) of one day; temperature of 30 °C; and recirculation ratio of five times the flow. An experimental central composite rotational delineation (CCRD) type design was used to define the aeration conditions and nitrogen load (factors) to be studied. Response surface methodology was used to analyse the influence of the factors above the results, the removal of TN and COD. It was observed that the aeration factor showed the greatest significance for the results and that the affluent TKN concentration did not have a significant effect, at a 95% level of confidence, on COD removal. Throughout the experiment, the COD/N ratio remained between 3.2 and 3.8. The best results for COD and TN removal, 80% and 88%, respectively, were obtained with 158 min of aeration on a cycle of 180 min and 255 mg L(-1) of Total Kjeldahl Nitrogen (TKN) in the substrate.

  11. Reducing Volatile Disinfection By-Products in Treated Drinking Water Using Aeration Technologies (WaterRF Report 4441)

    EPA Science Inventory

    The primary objective of this project was to evaluate cost-effective aeration technology solutions to address TTHM compliance at a water treatment plant clearwell. The project team worked closely with EPA Region 6 and the EPA Office of Research and Development (ORD) to identify a...

  12. Do radial oxygen loss and external aeration affect iron plaque formation and arsenic accumulation and speciation in rice?

    PubMed

    Wu, Chuan; Ye, Zhihong; Li, Hui; Wu, Shengchun; Deng, Dan; Zhu, Yongguan; Wong, Minghung

    2012-05-01

    Hydroponic experiments were conducted to investigate the effect of radial oxygen loss (ROL) and external aeration on iron (Fe) plaque formation, and arsenic (As) accumulation and speciation in rice (Oryza sativa L.). The data showed that there were significant correlations between ROL and Fe concentrations in Fe plaque produced on different genotypes of rice. There were also significant differences in the amounts of Fe plaque formed between different genotypes in different positions of roots and under different aeration conditions (aerated, normal, and stagnant treatments). In aerated treatments, rice tended to have a higher Fe plaque formation than in a stagnant solution, with the greatest formation at the root tip decreasing with increasing distances away, in accordance with a trend of spatial ROL. Genotypes with higher rates of ROL induced higher degrees of Fe plaque formation. Plaques sequestered As on rice roots, with arsenate almost double that with arsenite, leading to decreased As accumulation in both roots and shoots. The major As species detected in roots and shoots was arsenite, ranging from 34 to 78% of the total As in the different treatments and genotypes. These results contribute to our understanding of genotypic differences in As uptake by rice and the mechanisms causing rice genotypes with higher ROL to show lower overall As accumulation.

  13. Do radial oxygen loss and external aeration affect iron plaque formation and arsenic accumulation and speciation in rice?

    PubMed Central

    Wu, Chuan; Ye, Zhihong; Li, Hui; Wu, Shengchun; Deng, Dan; Zhu, Yongguan; Wong, Minghung

    2012-01-01

    Hydroponic experiments were conducted to investigate the effect of radial oxygen loss (ROL) and external aeration on iron (Fe) plaque formation, and arsenic (As) accumulation and speciation in rice (Oryza sativa L.). The data showed that there were significant correlations between ROL and Fe concentrations in Fe plaque produced on different genotypes of rice. There were also significant differences in the amounts of Fe plaque formed between different genotypes in different positions of roots and under different aeration conditions (aerated, normal, and stagnant treatments). In aerated treatments, rice tended to have a higher Fe plaque formation than in a stagnant solution, with the greatest formation at the root tip decreasing with increasing distances away, in accordance with a trend of spatial ROL. Genotypes with higher rates of ROL induced higher degrees of Fe plaque formation. Plaques sequestered As on rice roots, with arsenate almost double that with arsenite, leading to decreased As accumulation in both roots and shoots. The major As species detected in roots and shoots was arsenite, ranging from 34 to 78% of the total As in the different treatments and genotypes. These results contribute to our understanding of genotypic differences in As uptake by rice and the mechanisms causing rice genotypes with higher ROL to show lower overall As accumulation. PMID:22345639

  14. Endocytosis, oxidative stress and IL-8 expression in human lung epithelial cells upon treatment with fine and ultrafine TiO{sub 2}: Role of the specific surface area and of surface methylation of the particles

    SciTech Connect

    Singh, Seema |; Shi, Tingming |; Duffin, Rodger |; Albrecht, Catrin; Berlo, Damien van; Hoehr, Doris; Fubini, Bice; Martra, Gianmario; Fenoglio, Ivana; Borm, Paul J.A. |; Schins, Roel P.F. . E-mail: roel.schins@uni-duesseldorf.de

    2007-07-15

    Inhaled ultrafine particles show considerably stronger pulmonary inflammatory effects when tested at equal mass dose with their fine counterparts. However, the responsible mechanisms are not yet fully understood. We investigated the role of particle size and surface chemistry in initiating pro-inflammatory effects in vitro in A549 human lung epithelial cells on treatment with different model TiO{sub 2} particles. Two samples of TiO{sub 2}, i.e. fine (40-300 nm) and ultrafine (20-80 nm) were tested in their native forms as well as upon surface methylation, as was confirmed by Fourier transformed infrared spectroscopy. Radical generation during cell treatment was determined by electron paramagnetic resonance with 5,5-dimethyl-1-pyrroline-N-oxide or 4-hydroxy-2,2,6,6-tetramethylpiperidine-1-oxyl. Interleukin-8 mRNA expression/release was determined by RT-PCR and ELISA, whereas particle uptake was evaluated by transmission electron microscopy. TiO{sub 2} particles were rapidly taken up by the cells, generally as membrane bound aggregates and large intracellular aggregates in vesicles, vacuoles and lamellar bodies. Aggregate size tended to be smaller for the ultrafine samples and was also smaller for methylated fine TiO{sub 2} when compared to non-methylated fine TiO{sub 2}. No particles were observed inside nuclei or any other vital organelle. Both ultrafine TiO{sub 2} samples but not their fine counterparts elicited significantly stronger oxidant generation and IL-8 release, despite their aggregation state and irrespective of their methylation. The present data indicate that ultrafine TiO{sub 2}, even as aggregates/agglomerates, can trigger inflammatory responses that appear to be driven by their large surface area. Furthermore, our results indicate that these effects result from oxidants generated during particle-cell interactions through a yet to be elucidated mechanism(s)

  15. Lung Cancer in Never Smokers

    PubMed Central

    Yang, Ping

    2012-01-01

    Lung cancer in never smokers (LCINS) has lately been recognized as a unique disease based on rapidly gained knowledge from genomic changes to treatment responses. The focus of this article is on current knowledge and challenges with regard to LCINS expanded from recent reviews highlighting five areas: (1) distribution of LCINS by temporal trends, geographic regions, and populations; (2) three well-recognized environmental risk factors; (3) other plausible environmental risk factors; (4) prior chronic lung diseases and infectious diseases as risk factors; and (5) lifestyles as risk or protective factors. This article will also bring attention to recently published literature in two pioneering areas: (1) histological characteristics, clinical features with emerging new effective therapies, and social and psychological stigma; and (2) searching for susceptibility genes using integrated genomic approaches. PMID:21500120

  16. In situ activity recovery of aging biofilm in biological aerated filter: Surfactants treatment and mechanisms study.

    PubMed

    Yu, Qisheng; Huang, Hui; Ren, Hongqiang; Ding, Lili; Geng, Jinju

    2016-11-01

    In situ activity recovery of aging biofilm in the biological aerated filter (BAF) is an important but underappreciated problem. Lab-scaled BAFs were established in this study and three kinds of surfactants containing sodium dodecyl sulfate (SDS), sodium dodecyl benzene sulfonate (SDBS) and rhamnolipid were employed. Multiple indicators including effluent qualities, dissolved organic matters, biofilm physiology and morphology characteristics were investigated to explore the mechanisms. Results showed that removal rates of effluent COD in test groups significantly recovered to the level before aging. Compared with the control, effluent in SDBS and rhamnolipid-treated groups obtained more protein-like and humic-like substances, respectively. Furthermore, great live cell ratio, smooth surface and low adhesion force of biofilm were observed after rhamnolipid treatment, which was in consistent with good effluent qualities in the same group. This is the first report of applying rhamnolipid for in situ activity recovery of aging biofilm in bioreactors. PMID:27513646

  17. Maximizing the xylitol production from sugar cane bagasse hydrolysate by controlling the aeration rate.

    PubMed

    Silva, S S; Ribeiro, J D; Felipe, M G; Vitolo, M

    1997-01-01

    Batch fermentations of sugar cane bagasse hemicellulosic hydrolysate treated for removing the inhibitors of the fermentation were performed by Candida guilliermondii FTI20037 for xylitol production. The fermentative parameters agitation and aeration rate were studied aiming the maximization of xylitol production from this agroindustrial residue. The maximal xylitol volumetric productivity (0.87 g/L h) and yield (0.67 g/g) were attained at 400/min and 0.45 v.v.m. (K(L)a 27/h). According to the results, a suitable control of the oxygen input permitting the xylitol formation from sugar cane bagasse hydrolysate is required for the development of an efficient fermentation process for large-scale applications.

  18. Modelling nitrogen and carbon interactions in composting of animal manure in naturally aerated piles.

    PubMed

    Oudart, D; Robin, P; Paillat, J M; Paul, E

    2015-12-01

    Composting animal manure with natural aeration is a low-cost and low-energy process that can improve nitrogen recycling in millions of farms world-wide. Modelling can decrease the cost of choosing the best options for solid manure management in order to decrease the risk of loss of fertilizer value and ammonia emission. Semi-empirical models are suitable, considering the scarce data available in farm situations. Eleven static piles of pig or poultry manure were monitored to identify the main processes governing nitrogen transformations and losses. A new model was implemented to represent these processes in a pile considered as homogeneous. The model is based on four modules: biodegradation, nitrogen transformations and volatilization, thermal exchanges, and free air space evolution. When necessary, the parameters were calibrated with the data set. The results showed that microbial growth could reduce ammonia volatilization. Greatest nitrogen conservation is achieved when microbial growth was limited by nitrogen availability.

  19. Influence of water cavitation peening with aeration on fatigue behaviour of SAE1045 steel

    NASA Astrophysics Data System (ADS)

    Han, B.; Ju, D. Y.; Jia, W. P.

    2007-10-01

    Water cavitation peening (WCP) with aeration is a recent potential method in the surface enhancement techniques. In this method, a ventilation nozzle is adopted to improve the process capability of WCP by increasing the impact pressure, which is induced by the bubble collapse on the surface of components in the similar way as conventional shot peening. In this paper, fatigue tests were conducted on the both-edge-notched flat tensile specimens to assess the influences of WCP on fatigue behaviour of SAE1045 steel. The notched specimens were treated by WCP, and the compressive residual stress distributions in the superficial layer were measured by X-ray diffraction method. The tension-tension ( R = Smin/ Smax = 0.1, f = 10 Hz) fatigue tests and the fracture surfaces observation by scan electron microscopy (SEM) were conducted. The experimental results show that WCP can improve the fatigue life by inducing the residual compressive stress in the superficial layer of mechanical components.

  20. Possibility of sewage and combined sewer overflow reuse with biological aerated filters.

    PubMed

    Kim, S W; Park, J B; Choi, E

    2007-01-01

    The secondary effluent from municipal plants in Korea generally represents higher BOD with lower SS. Therefore, more soluble forms of organics and NH4-N need to be removed to improve its effluent for reuse. In this study reuse possibility of secondary effluent and CSO (combined sewer overflow) using BAF (biological aerated filter) was evaluated. The tertiary application with 1.2 h EBCT, SS, BOD and COD showed stable concentrations less than 1.3, 1.3 and 6.2 mg/L, respectively. Nitrogen could be nitrified even at 7 degrees suggesting BAF can be used for a water reuse method as well as an effective add-on facility in cold regions. However, BAF was not stable with CSO application at increased flow rates suggesting CSO must be equalised prior to application. Disinfection was necessary even during normal weather conditions. PMID:17305117

  1. Aqueous vapor extraction: a previously unrecognized weathering process affecting oil spills in vigorously aerated water.

    PubMed

    Prince, Roger C; Stibrany, Robert T; Hardenstine, Jeffrey; Douglas, Gregory S; Owens, Edward H

    2002-07-01

    Simple evaporation of spilled oil is usually thought to be restricted to the smaller hydrocarbons (<15 carbons). We show that aeration of oil in water, at 22 degrees C, substantially extends this evaporation, leading to the loss of alkanes up to at least hexatricosane (nC36) and of polycyclic aromatic hydrocarbons with at least four rings (e.g., chrysene and its alkylated forms). This phenomenon is apparently related to steam distillation and should be considered as an important candidate pathway to explain the observed weathering of oil spilled from the OSSA II pipeline into the Río Desaguadero on the Bolivian Altiplano (approximately 3700 m), which occurred during a very turbulent flood.

  2. The effect of cohesive forces on the fluidization of aeratable powders

    SciTech Connect

    Galvin, Janine F.; Benyahia, Sofiane

    2014-01-01

    The effects of cohesive forces of van der Waals type in the fluidization/defluidization of aeratable type A powders in the Geldart classification are numerically investigated. The effects of friction and particle-size distribution (PSD) on some design-significant parameters, such as minimum fluidization and bubbling velocities, are also investigated. For these types of particles, cohesive forces are observed as necessary to fully exhibit the role friction plays in commonly observed phenomena, such as pressure overshoot and hysteresis around minimum fluidization. This study also shows that a full-experimental PSD consisting of a dozen particle sizes may be sufficiently represented by a few particle diameters. Reducing the number of particle types may benefit the continuum approach, which is based on the kinetic theory of granular flow, by reducing computational expense, while still maintaining the accuracy of the predictions.

  3. Modelling nitrogen and carbon interactions in composting of animal manure in naturally aerated piles.

    PubMed

    Oudart, D; Robin, P; Paillat, J M; Paul, E

    2015-12-01

    Composting animal manure with natural aeration is a low-cost and low-energy process that can improve nitrogen recycling in millions of farms world-wide. Modelling can decrease the cost of choosing the best options for solid manure management in order to decrease the risk of loss of fertilizer value and ammonia emission. Semi-empirical models are suitable, considering the scarce data available in farm situations. Eleven static piles of pig or poultry manure were monitored to identify the main processes governing nitrogen transformations and losses. A new model was implemented to represent these processes in a pile considered as homogeneous. The model is based on four modules: biodegradation, nitrogen transformations and volatilization, thermal exchanges, and free air space evolution. When necessary, the parameters were calibrated with the data set. The results showed that microbial growth could reduce ammonia volatilization. Greatest nitrogen conservation is achieved when microbial growth was limited by nitrogen availability. PMID:26403389

  4. Maximizing the xylitol production from sugar cane bagasse hydrolysate by controlling the aeration rate

    SciTech Connect

    Silva, S.S.; Ribeiro, J.D.; Felipe, M.G.A.; Vitolo, M.

    1997-12-31

    Batch fermentations of sugar cane bagasse hemicellulosic hydrolysate treated for removing the inhibitors of the fermentation were performed by Candida guilliermondii FTI 20037 for xylitol production. The fermentative parameters agitation and aeration rate were studied aiming the maximization of xylitol production from this agroindustrial residue. The maximal xylitol volumetric productivity (0.87 g/L {center_dot} h) and yield (0.67 g/g) were attained at 400/min and 0.45 v.v.m. (K{sub L}a 27/h). According to the results, a suitable control of the oxygen input permitting the xylitol formation from sugar cane bagasse hydrolysate is required for the development of an efficient fermentation process for large-scale applications. 20 refs., 2 figs.

  5. [Biocenotic dynamics of liquid sewage in the process of its biological purification at aeration stations].

    PubMed

    Kalina, G P; Vinogradova, L A; Gipp, E K

    1975-08-01

    A study was made of biological purification of sewage at the aeration stations on the quantitative composition of the main indicator microbes--of bacteria of the coliform group and of the fecal coliform bacilli, enterococci, Proteus, and also pathogenic enterobacteria. There was found a difference in the behaviour of different species of Proteus, i.e. reduction in the process of purification in the numbers of Pr. mirabilis, and a sharp elevation of Pr. morganii content. There was noted an insignificant amount of Pr. vulgaris both before and after the biological purification. It was found that dynamics of biocenosis was influenced by air temperature at the time of collection of the samples. A possibility of reproduction of coliform bacilli serving as one of the factors of autopurification of sewage during the biological purification was confirmed.

  6. Aeration and mass transfer optimization in a rectangular airlift loop photobioreactor for the production of microalgae.

    PubMed

    Guo, Xin; Yao, Lishan; Huang, Qingshan

    2015-08-01

    Effects of superficial gas velocity and top clearance on gas holdup, liquid circulation velocity, mixing time, and mass transfer coefficient are investigated in a new airlift loop photobioreactor (PBR), and empirical models for its rational control and scale-up are proposed. In addition, the impact of top clearance on hydrodynamics, especially on the gas holdup in the internal airlift loop reactor, is clarified; a novel volume expansion technique is developed to determine the low gas holdup in the PBR. Moreover, a model strain of Chlorella vulgaris is cultivated in the PBR and the volumetric power is analyzed with a classic model, and then the aeration is optimized. It shows that the designed PBR, a cost-effective reactor, is promising for the mass cultivation of microalgae. PMID:25958141

  7. Optimization Of The Alternate Cycle In A Membrane Aeration/Filtration Combined Bioreactor

    NASA Astrophysics Data System (ADS)

    Wang, Hongjie; Dong, Wenyi; Yang, Yue; Gan, Guanghua; Li, Weiguang

    2010-11-01

    In this study, a membrane aeration/filtration combined bioreactor (CMBR) was constructed, and the effect of alternate cycle by CMBR on membrane fouling and oxygen utilization efficiency (OUE) was investigated. Results showed that under the condition, when the alternate cycle was 0.75˜3h, the ΔTMP (TMP value of the time when a filtration cycle was over) of CMBR maintained a basically constant value during the 6 days' continuous operation, which implied the CMBR achieved a favorable effect of the membrane fouling relieving. Too short or too long cycle would lead to a gradual increase of ΔTMP. OUE of CMBR increased with the extension of the alternate cycle. Thus, it suggested that the optimal alternate cycle of CMBR should be 3h.

  8. Kinetics of inactivation of Pseudomonas aeruginosa in aqueous solutions by ozone aeration.

    PubMed

    Zuma, Favourite N; Lin, Johnson; Jonnalagadda, S B

    2009-08-01

    The effect of ozonation on the disinfection of Gram-negative strain, Pseudomonas aeruginosa was investigated as a function of time. Ozone was generated in situ using corona discharge method, with ozone concentrations ranging from (0.29-9.84) x 10(-5) moles L(-1). The microbial inactivation kinetics followed pseudo-first-order kinetics under excess concentration conditions of ozone. With over all second-order constant, k = (4.02 +/- 0.20) x 10(4) M(-1) min(-1), the reaction rate had first-order dependence both on the microbial count and ozone. The influence of temperature and pH on the ozone initiated disinfection of the microbe was also investigated. Molecular ozone is found more effective in disinfection than hydroxyl radicals. Probable mechanism for antimicrobial power of ozone in water systems is discussed. The ozone aeration decreased the biochemical oxygen demand (BOD) value of natural and microbe spiked waters significantly.

  9. Solar detoxification of wastewater in a novel aerated cascade photoreactor (ACP).

    PubMed

    Xi, W; Geissen, S U; Vogelpohl, A

    2001-01-01

    A newly developed aerated cascade photoreactor (ACP), based on a non-concentrating suspension photoreactor, combines the advantages of a cascade with the increased mass-transfer and the use of oxygen from air as an oxidizing agent in a bubble column. Systematic studies of the limiting hydrodynamic conditions in the ACP and the solid/liquid-separation of the photocatalyst from the treated wastewater have shown that the ACP is technically and commercially attractive. The ACP outperforms the thin-film fixed-bed reactor (TFFBR) with respect to a 3-13 times higher degradation efficiency for the model compound dichloroacetic acid (DCA). The treatment of two biologically pretreated real wastewaters, one from a textile factory and one from car-washing, have been successfully carried out under artificial light and sunlight.

  10. Effects of aeration on formation and localization of the acetyl coenzyme A synthetases of Saccharomyces cerevisiae

    NASA Technical Reports Server (NTRS)

    Klein, H. P.; Jahnke, L.

    1979-01-01

    Previous studies on the yeast Saccharomyces cerevisiae have shown that two different forms of the enzyme acetyl coenzyme A synthetase (ACS) are present, depending on the conditions under which the cells are grown. The paper evaluates the usefulness of a method designed to assay both synthetases simultaneously in yeast homogenates. The data presented confirm the possibility of simultaneous detection and estimation of the amount of both ACSs of S. cerevisiae in crude homogenates of this strain, making possible the study of physiological factors involved in the formation of these isoenzymes. One important factor for specifying which of the two enzymes is found in these yeast cells is the presence or absence of oxygen in their environment. Aeration not only affects the ratio of the two ACSs but also appears to affect the cellular distribution of these enzymes. Most of the data presented suggest the possibility that the nonaerobic ACS may serve as a precursor to the aerobic form.

  11. A combined system of microbial fuel cell and intermittently aerated biological filter for energy self-sufficient wastewater treatment.

    PubMed

    Dong, Yue; Feng, Yujie; Qu, Youpeng; Du, Yue; Zhou, Xiangtong; Liu, Jia

    2015-01-01

    Energy self-sufficiency is a highly desirable goal of sustainable wastewater treatment. Herein, a combined system of a microbial fuel cell and an intermittently aerated biological filter (MFC-IABF) was designed and operated in an energy self-sufficient manner. The system was fed with synthetic wastewater (COD = 1000 mg L(-1)) in continuous mode for more than 3 months at room temperature (~25 °C). Voltage output was increased to 5 ± 0.4 V using a capacitor-based circuit. The MFC produced electricity to power the pumping and aeration systems in IABF, concomitantly removing COD. The IABF operating under an intermittent aeration mode (aeration rate 1000 ± 80 mL h(-1)) removed the residual nutrients and improved the water quality at HRT = 7.2 h. This two-stage combined system obtained 93.9% SCOD removal and 91.7% TCOD removal (effluent SCOD = 61 mg L(-1), TCOD = 82.8 mg L(-1)). Energy analysis indicated that the MFC unit produced sufficient energy (0.27 kWh m(-3)) to support the pumping system (0.014 kWh m(-3)) and aeration system (0.22 kWh m(-3)). These results demonstrated that the combined MFC-IABF system could be operated in an energy self-sufficient manner, resulting to high-quality effluent. PMID:26666392

  12. A combined system of microbial fuel cell and intermittently aerated biological filter for energy self-sufficient wastewater treatment

    PubMed Central

    Dong, Yue; Feng, Yujie; Qu, Youpeng; Du, Yue; Zhou, Xiangtong; Liu, Jia

    2015-01-01

    Energy self-sufficiency is a highly desirable goal of sustainable wastewater treatment. Herein, a combined system of a microbial fuel cell and an intermittently aerated biological filter (MFC-IABF) was designed and operated in an energy self-sufficient manner. The system was fed with synthetic wastewater (COD = 1000 mg L−1) in continuous mode for more than 3 months at room temperature (~25 °C). Voltage output was increased to 5 ± 0.4 V using a capacitor-based circuit. The MFC produced electricity to power the pumping and aeration systems in IABF, concomitantly removing COD. The IABF operating under an intermittent aeration mode (aeration rate 1000 ± 80 mL h−1) removed the residual nutrients and improved the water quality at HRT = 7.2 h. This two-stage combined system obtained 93.9% SCOD removal and 91.7% TCOD removal (effluent SCOD = 61 mg L−1, TCOD = 82.8 mg L−1). Energy analysis indicated that the MFC unit produced sufficient energy (0.27 kWh m−3) to support the pumping system (0.014 kWh m−3) and aeration system (0.22 kWh m−3). These results demonstrated that the combined MFC-IABF system could be operated in an energy self-sufficient manner, resulting to high-quality effluent. PMID:26666392

  13. [Emissions of greenhouse gas and ammonia from sewage sludge composting by continuous aerated turning pile].

    PubMed

    Zhao, Chen-Yang; Wei, Yuan-Song; Ge, Zhen; Zhong, Jia; Cai, Xing; Zhang, Yuan-Li; Li, Hong-Mei

    2014-07-01

    There is a lack of observation data on greenhouse gas (GHG) and ammonia emissions from sewage sludge composting, though the emissions can result in environmental issue and nitrogen loss. In this study, GHG and ammonia emissions were monitored under different operating parameters during sludge composting with continuous aerated turning pile at full scale. Results illustrated that the reduction of amendment addition could result in low organic matter transformation (1.38% and 8.85% for the test group and the control group, respectively). Though low C/N ratio might slightly increase the ammonia emission (8.68% higher than the control group), it was helpful to reduce both GHG emission (1.70 g x kg(-1)) DC for the test group and 2.85 g x kg(-1) DC for the control group, respectively) and total nitrogen loss (16.1% and 21.8% for the test and control groups, respectively). Through applying an aertion strategy in which the airflow rate was lower in the beginning and higher in the end of sludge composting, a higher GHG emission and a lower ammonia emission were observed in the test group, e. g., 55.1% higher of GHG emission than the control, and 66.86 g x m(-2) and 72.04 g x m(-2) of ammonia emission in the test and the control, respectively. And a good conversation of total nitrogen thus occurred in the test as a result of such aeration strategy, with only 51.34% of TN loss as compared to the control.

  14. Total nitrogen removal in a hybrid, membrane-aerated activated sludge process.

    PubMed

    Downing, Leon S; Nerenberg, Robert

    2008-08-01

    The hybrid (suspended and attached growth) membrane biofilm process (HMBP) is a novel method to achieve total nitrogen removal from wastewater. Air-filled hollow-fiber membranes are incorporated into an activated sludge tank, and a nitrifying biofilm develops on the membranes, producing nitrite and nitrate. By suppressing bulk aeration, the bulk liquid becomes anoxic, and the nitrate/nitrite can be reduced with influent BOD. The key feature that distinguishes the HMBP from other membrane-aerated processes is that it is hybrid; heterotrophic bacteria are kept mainly in suspension by maintaining low bulk liquid BOD concentrations. We investigated the HMBP's performance under a variety of BOD and ammonium loadings, and determined the dominant mechanisms of nitrogen removal. Suspended solids increased with the BOD loadings, maintaining low bulk liquid BOD concentrations. As a result, nitrification rates were insensitive to the BOD loadings, remaining at 1gNm(-2)day(-1) for BOD loadings ranging from 4 to 17gBODm(-2)day(-1). Nitrification rates decreased during short-term spikes in bulk liquid BOD concentrations. Shortcut nitrogen removal was confirmed using microsensor measurements, showing that nitrite was the dominant form of oxidized nitrogen produced by the biofilm. Fluorescence in situ hybridization (FISH) showed that ammonia oxidizing bacteria (AOB) were dominant throughout the biofilm, while nitrite oxidizing bacteria (NOB) were only present in the deeper regions of the biofilm, where the oxygen concentration was above 2mg/L. Denitrification occurred mainly in the suspended phase, instead of in the biofilm, decreasing the potential for biofouling. When influent BOD concentrations were sufficiently high, full denitrification occurred, with total nitrogen (TN) removal approaching 100%. These results suggest that the process is well-suited for achieving concurrent BOD and TN removal in activated sludge.

  15. Reduction of estrogenic activity of municipal wastewater by aerated lagoon treatment facilities.

    PubMed

    Bringolf, Robert B; Summerfelt, Robert C

    2003-01-01

    The estrogenic activity of municipal wastewater in aerated lagoon treatment facilities was evaluated using plasma concentrations of vitellogenin (Vtg) in male fathead minnows (Pimephales promelas). Caged fathead minnows were exposed for 10 to 12 d in three lagoons that are connected in series at each of 10 municipal wastewater treatment facilities in central Iowa, USA, during October and November 2000. Fathead minnows held in the laboratory served as unexposed controls. Pooled (n = 4-10 fish) plasma Vtg, quantified by enzyme-linked immunosorbent assay (ELISA), was 1,702 +/- 670 (mean +/- standard error [SE]) microg/ml in the first lagoons (n = 9), 0.94 +/- 0.36 microg/ml in the second lagoons (n = 10), and 0.04 +/- 0.02 microg/ml in the third lagoons (n = 8). Differences in mean fish plasma Vtg concentration among lagoons were highly significant (p < 0.001). The mean concentration of plasma Vtg in fish in the third lagoons was not significantly different (p = 0.990) from that of the control fish (0.04 +/- 0.02 microg/ml). Plasma Vtg concentrations of fish in the first lagoons were inversely correlated with wastewater retention time in the lagoons (p = 0.002, r = -0.877). Water temperatures of the final effluents during the study ranged from 9 to 12 degrees C. General treatment efficiency of lagoons has been shown to be dependent on temperature, so the potential exists for decreased removal of estrogenic activity when water temperatures are lower (e.g., winter months) than the present study. In conclusion, wastewater entering aerated lagoon systems was estrogenic to fish, but with serial passage through the lagoons, the estrogenic activity decreased to a level that was not sufficient to induce vitellogenesis in male fathead minnows in a 10- to 12-d exposure.

  16. [Atrazine wastewater treatment in a SPG membrane-aerated genetically engineered microorganism biofilm reactor].

    PubMed

    Liu, Chun; Gong, Peng-Fei; Xiao, Tai-Min; Zhang, Ming; Nian, Yong-Jia; Yang, Jing-Liang; Zhang, Jing

    2014-08-01

    Membrane-aerated biofilm reactor (MABR) represent a novel membrane-biological wastewater treatment technology. In addition, bioaugmented treatment using genetically engineered microorganism (GEM) biofilm in MABR is proposed to improve refractory pollutant removal. In the present study, a SPG membrane aerated-biofilm reactor (SPG-MABR) with GEM biofilm formed on the SPG membrane surface was applied to treat atrazine wastewater. The influences of air pressure, biofilm biomass and liquid velocity on the performance of the SPG-MABR were investigated. The variation of GEM biofilm during the SPG-MABR operation was observed. The results indicated that the increased air pressure could promote atrazine and COD removal as well as re-oxygenation by increasing oxygen permeability coefficient. A higher biofilm biomass could also enhance atrazine and COD removal, but simultaneously reduce the re-oxygenation rate because biofilm thickness and oxygen transfer resistance increased. When liquid velocity in the SPG-MABR was decreased under laminar flow condition, atrazine and COD removal was improved due to the facilitated contaminant diffusion from wastewater to biofilm. The atrazine removal efficiency reached to 98.6% in the SPG-MABR after 5d treatment at air pressure of 300 kPa, biofilm biomass of 25 g x m(-2) and liquid velocity of 0.05 m x s(-1). The microbial polymorphism of GEM biofilm was observed during the SPG-MABR operation. The surface of GEM biofilm was gradually covered by other microbial cells and the distribution of GEM cells reduced, but inside the GEM biofilm, the GEM cells were still dominant.

  17. Partial flooding enhances aeration in adventitious roots of black willow (Salix nigra) cuttings.

    PubMed

    Li, Shuwen; Reza Pezeshki, S; Douglas Shields, F

    2006-04-01

    Black willow (Salix nigra) cuttings are used for streambank stabilization where they are subjected to a range of soil moisture conditions including flooding. Flooding has been shown to adversely impact cutting performance, and improved understanding of natural adaptations to flooding might suggest handling and planting techniques to enhance success. However, data assessing the root aeration in adventitious roots that are developed on cuttings of woody species are scant. In addition, it appears that no data are available regarding aeration of the root system under partially flooded conditions. This experiment was designed to examine the effects of continuous flooding (CF) and partial flooding (PF) on aerenchyma formation and radial oxygen loss (ROL) in black willow cuttings. Photosynthetic and growth responses to these conditions were also investigated. Under laboratory condition, replicated potted cuttings were subjected to three treatments: no flooding (control, C), CF, and PF. Water was maintained above the soil surface in CF and at 10 cm depth in PF. Results indicated that after the 28-d treatments, root porosity ranged between 28.6% and 33.0% for the CF and C plants but was greater for the PF plants (39.2% for the drained and 37.2% for the flooded portions). A similar response pattern was found for ROL. In addition, CF treatment led to decreases in final root biomass and root/shoot ratio. Neither CF nor PF had any detectable adverse effects on plant gas exchange or photosystem II functioning. Our results indicated that S. nigra cuttings exhibited avoidance mechanisms in response to flooding, especially the partially flooded condition which is the most common occurrence in riparian systems.

  18. Indoor radon and lung cancer in China

    SciTech Connect

    Blot, W.J.; Xu, Z.Y.; Boice, J.D. Jr.; Zhao, D.Z.; Stone, B.J.; Sun, J.; Jing, L.B.; Fraumeni, J.F. Jr. )

    1990-06-20

    Radon has long been known to contribute to risk of lung cancer, especially in undergound miners who are exposed to large amounts of the carcinogen. Recently, however, lower amounts of radon present in living areas have been suggested as an important cause of lung cancer. In an effort to clarify the relationship of low amounts of radon with lung cancer risk, we placed alpha-track radon detectors in the homes of 308 women with newly diagnosed lung cancer and 356 randomly selected female control subjects of similar age. Measurements were taken after 1 year. All study participants were part of the general population of Shenyang, People's Republic of China, an industrial city in the northeast part of the country that has one of the world's highest rates of lung cancer in women. The median time of residence in the homes was 24 years. The median household radon level was 2.3 pCi/L of air; 20% of the levels were greater than 4 pCi/L. Radon levels tended to be higher in single-story houses or on the first floor of multiple-story dwellings, and they were also higher in houses with increased levels of indoor air pollution from coal-burning stoves. However, the levels were not higher in homes of women who developed lung cancer than in homes of controls, nor did lung cancer risk increase with increasing radon level. No association between radon and lung cancer was observed regardless of cigarette-smoking status, except for a nonsignificant trend among heavy smokers. No positive associations of lung cancer cell type with radon were observed, except for a nonsignificant excess risk of small cell cancers among the more heavily exposed residents. Our data suggest that projections from surveys of miners exposed to high radon levels may have overestimated the overall risks of lung cancer associated with levels typically seen in homes in this Chinese city.

  19. Effects of chemical oxygen demand (COD)/N ratios on pollutants removal in the subsurface wastewater infiltration systems with/without intermittent aeration.

    PubMed

    Song, Siyu; Pan, Jing; Wu, Shiwei; Guo, Yijing; Yu, Jingxiao; Shan, Qingchi

    2016-01-01

    The matrix oxidation reduction potential level, organic pollutants and nitrogen removal performances of eight subsurface wastewater infiltration systems (SWISs) (four with intermittent aeration, four without intermittent aeration) fed with influent chemical oxygen demand (COD)/N ratio of 3, 6, 12 and 18 were investigated. Nitrification of non-aerated SWISs was poor due to oxygen deficiency while higher COD/N ratios further led to lower COD and nitrogen removal rate. Intermittent aeration achieved almost complete nitrification, which successfully created aerobic conditions in the depth of 50 cm and did not change anoxic or anaerobic conditions in the depth of 80 and 110 cm. The sufficient carbon source in high COD/N ratio influent greatly promoted denitrification in SWISs with intermittent aeration. High average removal rates of COD (95.68%), ammonia nitrogen (NH4(+)-N) (99.32%) and total nitrogen (TN) (89.65%) were obtained with influent COD/N ratio of 12 in aerated SWISs. The results suggest that intermittent aeration was a reliable option to achieve high nitrogen removal in SWISs, especially with high COD/N ratio wastewater.

  20. Influence of aeration on CH4, N2O and NH3 emissions during aerobic composting of a chicken manure and high C/N waste mixture.

    PubMed

    Shen, Yujun; Ren, Limei; Li, Guoxue; Chen, Tongbin; Guo, Rui

    2011-01-01

    Co-composting of chicken manure, straw and dry grasses was investigated in a forced aeration system to estimate the effect of aeration rates on NH(3), CH(4) and N(2)O emissions and compost quality. Continuous measurements of gas emissions were carried out and detailed gas emission patterns were obtained using an intermittent-aeration of 30 min on/30 min off at rates of 0.01 (A1), 0.1 (A2) and 0.2 (A3) m(3)min(-1)m(-3). Concentrations of CH(4) and N(2)O at the low aeration rate (A1) were significantly greater than those at the other two rates, but there was no significant difference between the A2 and A3 treatments. CH(4) and N(2)O emissions for this mixture could be controlled when the composting process was aerobic and ammonia emissions were reduced at a lower aeration rate. Comparison of CH(4), N(2)O, NH(3) emissions and compost quality showed that the aeration rate of the A2 treatment was superior to the other two aeration rates. PMID:20888749