Science.gov

Sample records for aerated lung areas

  1. Ventilation/perfusion mismatch during lung aeration at birth.

    PubMed

    Lang, Justin A R; Pearson, James T; te Pas, Arjan B; Wallace, Megan J; Siew, Melissa L; Kitchen, Marcus J; Fouras, Andreas; Lewis, Robert A; Wheeler, Kevin I; Polglase, Graeme R; Shirai, Mikiyasu; Sonobe, Takashi; Hooper, Stuart B

    2014-09-01

    At birth, the transition to newborn life is triggered by lung aeration, which stimulates a large increase in pulmonary blood flow (PBF). Current theories predict that the increase in PBF is spatially related to ventilated lung regions as they aerate after birth. Using simultaneous phase-contrast X-ray imaging and angiography we investigated the spatial relationships between lung aeration and the increase in PBF after birth. Six near-term (30-day gestation) rabbits were delivered by caesarean section, intubated and an intravenous catheter inserted, before they were positioned for X-ray imaging. During imaging, iodine was injected before ventilation onset, after ventilation of the right lung only, and after ventilation of both lungs. Unilateral ventilation increased iodine levels entering both left and right pulmonary arteries (PAs) and significantly increased heart rate, iodine ejection per beat, diameters of both left and right PAs, and number of visible vessels in both lungs. Within the 6th intercostal space, the mean gray level (relative measure of iodine level) increased from 68.3 ± 11.6 and 70.3 ± 7.5%·s to 136.3 ± 22.6 and 136.3 ± 23.7%·s in the left and right PAs, respectively. No differences were observed between vessels in the left and right lungs, despite the left lung not initially being ventilated. The increase in PBF at birth is not spatially related to lung aeration allowing a large ventilation/perfusion mismatch, or pulmonary shunting, to occur in the partially aerated lung at birth. PMID:24994883

  2. Mild loss of lung aeration augments stretch in healthy lung regions.

    PubMed

    Cereda, Maurizio; Xin, Yi; Hamedani, Hooman; Clapp, Justin; Kadlecek, Stephen; Meeder, Natalie; Zeng, Johnathan; Profka, Harrilla; Kavanagh, Brian P; Rizi, Rahim R

    2016-02-15

    Inspiratory stretch by mechanical ventilation worsens lung injury. However, it is not clear whether and how the ventilator damages lungs in the absence of preexisting injury. We hypothesized that subtle loss of lung aeration during general anesthesia regionally augments ventilation and distension of ventilated air spaces. In eight supine anesthetized and intubated rats, hyperpolarized gas MRI was performed after a recruitment maneuver following 1 h of volume-controlled ventilation with zero positive end-expiratory pressure (ZEEP), FiO2 0.5, and tidal volume 10 ml/kg, and after a second recruitment maneuver. Regional fractional ventilation (FV), apparent diffusion coefficient (ADC) of (3)He (a measurement of ventilated peripheral air space dimensions), and gas volume were measured in lung quadrants of ventral and dorsal regions of the lungs. In six additional rats, computed tomography (CT) images were obtained at each time point. Ventilation with ZEEP decreased total lung gas volume and increased both FV and ADC in all studied regions. Increases in FV were more evident in the dorsal slices. In each lung quadrant, higher ADC was predicted by lower gas volume and by increased mean values (and heterogeneity) of FV distribution. CT scans documented 10% loss of whole-lung aeration and increased density in the dorsal lung, but no macroscopic atelectasis. Loss of pulmonary gas at ZEEP increased fractional ventilation and inspiratory dimensions of ventilated peripheral air spaces. Such regional changes could help explain a propensity for mechanical ventilation to contribute to lung injury in previously uninjured lungs. PMID:26662053

  3. Expired CO2 Levels Indicate Degree of Lung Aeration at Birth

    PubMed Central

    Hooper, Stuart B.; Fouras, Andreas; Siew, Melissa L.; Wallace, Megan J.; Kitchen, Marcus J.; Pas, Arjan B. te.; Klingenberg, Claus; Lewis, Robert A.; Davis, Peter G.; Morley, Colin J.; Schmölzer, Georg M.

    2013-01-01

    As neonatal resuscitation critically depends upon lung aeration at birth, knowledge of the progression of this process is required to guide ongoing care. We investigated whether expired CO2 (ECO2) levels indicate the degree of lung aeration immediately after birth in two animal models and in preterm infants. Lambs were delivered by caesarean section and ventilated from birth. In lambs, ECO2 levels were significantly (p<0.0001) related to tidal volumes and CO2 clearance/breath increased exponentially when tidal volumes were greater than 6 mL/kg. Preterm (28 days of gestation; term = 32 days) rabbits were also delivered by caesarean section and lung aeration was measured using phase contrast X-ray imaging. In rabbit kittens, ECO2 levels were closely related (p<0.001) to lung volumes at end-inflation and were first detected when ∼7% of the distal lung regions were aerated. ECO2 levels in preterm infants at birth also correlated with tidal volumes. In each infant, ECO2 levels increased to >10 mmHg 28 (median) (21–36) seconds before the heart rate increased above 100 beats per minute. These data demonstrate that ECO2 levels can indicate the relative degree of lung aeration after birth and can be used to clinically assess ventilation in the immediate newborn period. PMID:23951032

  4. Spatiotemporal Aeration and Lung Injury Patterns Are Influenced by the First Inflation Strategy at Birth.

    PubMed

    Tingay, David G; Rajapaksa, Anushi; Zonneveld, C Elroy; Black, Don; Perkins, Elizabeth J; Adler, Andy; Grychtol, Bartłomiej; Lavizzari, Anna; Frerichs, Inéz; Zahra, Valerie A; Davis, Peter G

    2016-02-01

    Ineffective aeration during the first inflations at birth creates regional aeration and ventilation defects, initiating injurious pathways. This study aimed to compare a sustained first inflation at birth or dynamic end-expiratory supported recruitment during tidal inflations against ventilation without intentional recruitment on gas exchange, lung mechanics, spatiotemporal regional aeration and tidal ventilation, and regional lung injury in preterm lambs. Lambs (127 ± 2 d gestation), instrumented at birth, were ventilated for 60 minutes from birth with either lung-protective positive pressure ventilation (control) or as per control after either an initial 30 seconds of 40 cm H2O sustained inflation (SI) or an initial stepwise end-expiratory pressure recruitment maneuver during tidal inflations (duration 180 s; open lung ventilation [OLV]). At study completion, molecular markers of lung injury were analyzed. The initial use of an OLV maneuver, but not SI, at birth resulted in improved lung compliance, oxygenation, end-expiratory lung volume, and reduced ventilatory needs compared with control, persisting throughout the study. These changes were due to more uniform inter- and intrasubject gravity-dependent spatiotemporal patterns of aeration (measured using electrical impedance tomography). Spatial distribution of tidal ventilation was more stable after either recruitment maneuver. All strategies caused regional lung injury patterns that mirrored associated regional volume states. Irrespective of strategy, spatiotemporal volume loss was consistently associated with up-regulation of early growth response-1 expression. Our results show that mechanical and molecular consequences of lung aeration at birth are not simply related to rapidity of fluid clearance; they are also related to spatiotemporal pressure-volume interactions within the lung during inflation and deflation. PMID:26186685

  5. Monitoring Lung Aeration during Respiratory Support in Preterm Infants at Birth

    PubMed Central

    Kang, Liane J.; Cheung, Po-Yin; Pichler, Gerhard; O’Reilly, Megan; Aziz, Khalid; Schmölzer, Georg M.

    2014-01-01

    Background If infants fail to initiate spontaneous breathing, resuscitation guidelines recommend respiratory support with positive pressure ventilation (PPV). The purpose of PPV is to establish functional residual capacity and deliver an adequate tidal volume (VT) to achieve gas exchange. Objective The aim of our pilot study was to measure changes in exhaled carbon dioxide (ECO2), VT, and rate of carbon dioxide elimination (VCO2) to assess lung aeration in preterm infants requiring respiratory support immediately after birth. Method A prospective observational study was performed between March and July 2013. Infants born at <37 weeks gestational age who received continuous positive airway pressure (CPAP) or PPV immediately after birth had VT delivery and ECO2 continuously recorded using a sensor attached to the facemask. Results Fifty-one preterm infants (mean (SD) gestational age 29 (3) weeks and birth weight 1425 (592 g)) receiving respiratory support in the delivery room were included. Infants in the CPAP group (n = 31) had higher ECO2 values during the first 10 min after birth compared to infants receiving PPV (n = 20) (ranging between 18–30 vs. 13–18 mmHg, p<0.05, respectively). At 10 min no significant difference in ECO2 values was observed. VT was lower in the CPAP group compared to the PPV group over the first 10 min ranging between 5.2–6.6 vs. and 7.2–11.3 mL/kg (p<0.05), respectively. Conclusions Immediately after birth, spontaneously breathing preterm infants supported via CPAP achieved better lung aeration compared to infants requiring PPV. PPV guided by VT and ECO2 potentially optimize lung aeration without excessive VT administered. PMID:25029553

  6. Optimizing lung aeration at birth using a sustained inflation and positive pressure ventilation in preterm rabbits

    PubMed Central

    te Pas, Arjan B.; Kitchen, Marcus J.; Lee, Katie; Wallace, Megan J.; Fouras, Andreas; Lewis, Robert A.; Yagi, Naoto; Uesugi, Kentaro; Hooper, Stuart B.

    2016-01-01

    Background: A sustained inflation (SI) facilitates lung aeration, but the most effective pressure and duration are unknown. We investigated the effect of gestational age (GA) and airway liquid volume on the required inflation pressure and SI duration. Methods: Rabbit kittens were delivered at 27, 29, and 30 d gestation, intubated and airway liquid was aspirated. Either no liquid (control) or 30 ml/kg of liquid was returned to the airways. Lung gas volumes were measured by plethysmography and phase-contrast X-ray-imaging. Starting at 22 cmH2O, airway pressure was increased until airflow commenced and pressure was then held constant. The SI was truncated when 20 ml/kg air had entered the lung and ventilation continued with intermittent positive pressure ventilation (iPPV). Results: Higher SI pressures and longer durations were required in 27-d kittens compared to 30-d kittens. During iPPV, 27-d kittens needed higher pressures and had lower functional residual capacity (FRC) compared to 30-d kittens. Adding lung liquid increased SI duration, reduced FRC, and increased resistance and pressures during iPPV in 29- and 30-d kittens. Conclusion: Immature kittens required higher starting pressures and longer SI durations to achieve a set inflation volume. Larger airway liquid volumes adversely affected lung function during iPPV in older but not young kittens. PMID:26991259

  7. Aerated Lagoons. Student Manual. Biological Treatment Process Control.

    ERIC Educational Resources Information Center

    Andersen, Lorri

    This student manual contains the textual material for a unit which focuses on the structural and operationally unique features of aerated lagoons. Topic areas discussed include: (1) characteristics of completely mixed aerated lagoons; (2) facultative aerated lagoons; (3) aerated oxidation ponds; (4) effects of temperature on aerated lagoons; (5)…

  8. Lung ventilation injures areas with discrete alveolar flooding, in a surface tension-dependent fashion.

    PubMed

    Wu, You; Kharge, Angana Banerjee; Perlman, Carrie E

    2014-10-01

    With proteinaceous-liquid flooding of discrete alveoli, a model of the edema pattern in the acute respiratory distress syndrome, lung inflation over expands aerated alveoli adjacent to flooded alveoli. Theoretical considerations suggest that the overexpansion may be proportional to surface tension, T. Yet recent evidence indicates proteinaceous edema liquid may not elevate T. Thus whether the overexpansion is injurious is not known. Here, working in the isolated, perfused rat lung, we quantify fluorescence movement from the vasculature to the alveolar liquid phase as a measure of overdistension injury to the alveolar-capillary barrier. We label the perfusate with fluorescence; micropuncture a surface alveolus and instill a controlled volume of nonfluorescent liquid to obtain a micropunctured-but-aerated region (control group) or a region with discrete alveolar flooding; image the region at a constant transpulmonary pressure of 5 cmH2O; apply five ventilation cycles with a positive end-expiratory pressure of 0-20 cmH2O and tidal volume of 6 or 12 ml/kg; return the lung to a constant transpulmonary pressure of 5 cmH2O; and image for an additional 10 min. In aerated areas, ventilation is not injurious. With discrete alveolar flooding, all ventilation protocols cause sustained injury. Greater positive end-expiratory pressure or tidal volume increases injury. Furthermore, we determine T and find injury increases with T. Inclusion of either plasma proteins or Survanta in the flooding liquid does not alter T or injury. Inclusion of 2.7-10% albumin and 1% Survanta together, however, lowers T and injury. Contrary to expectation, albumin inclusion in our model facilitates exogenous surfactant activity. PMID:25080924

  9. Lung ventilation injures areas with discrete alveolar flooding, in a surface tension-dependent fashion

    PubMed Central

    Wu (吴右), You; Kharge, Angana Banerjee

    2014-01-01

    With proteinaceous-liquid flooding of discrete alveoli, a model of the edema pattern in the acute respiratory distress syndrome, lung inflation over expands aerated alveoli adjacent to flooded alveoli. Theoretical considerations suggest that the overexpansion may be proportional to surface tension, T. Yet recent evidence indicates proteinaceous edema liquid may not elevate T. Thus whether the overexpansion is injurious is not known. Here, working in the isolated, perfused rat lung, we quantify fluorescence movement from the vasculature to the alveolar liquid phase as a measure of overdistension injury to the alveolar-capillary barrier. We label the perfusate with fluorescence; micropuncture a surface alveolus and instill a controlled volume of nonfluorescent liquid to obtain a micropunctured-but-aerated region (control group) or a region with discrete alveolar flooding; image the region at a constant transpulmonary pressure of 5 cmH2O; apply five ventilation cycles with a positive end-expiratory pressure of 0–20 cmH2O and tidal volume of 6 or 12 ml/kg; return the lung to a constant transpulmonary pressure of 5 cmH2O; and image for an additional 10 min. In aerated areas, ventilation is not injurious. With discrete alveolar flooding, all ventilation protocols cause sustained injury. Greater positive end-expiratory pressure or tidal volume increases injury. Furthermore, we determine T and find injury increases with T. Inclusion of either plasma proteins or Survanta in the flooding liquid does not alter T or injury. Inclusion of 2.7–10% albumin and 1% Survanta together, however, lowers T and injury. Contrary to expectation, albumin inclusion in our model facilitates exogenous surfactant activity. PMID:25080924

  10. Quantification of lung surface area using computed tomography

    PubMed Central

    2010-01-01

    Objective To refine the CT prediction of emphysema by comparing histology and CT for specific regions of lung. To incorporate both regional lung density measured by CT and cluster analysis of low attenuation areas for comparison with histological measurement of surface area per unit lung volume. Methods The histological surface area per unit lung volume was estimated for 140 samples taken from resected lung specimens of fourteen subjects. The region of the lung sampled for histology was located on the pre-operative CT scan; the regional CT median lung density and emphysematous lesion size were calculated using the X-ray attenuation values and a low attenuation cluster analysis. Linear mixed models were used to examine the relationships between histological surface area per unit lung volume and CT measures. Results The median CT lung density, low attenuation cluster analysis, and the combination of both were important predictors of surface area per unit lung volume measured by histology (p < 0.0001). Akaike's information criterion showed the model incorporating both parameters provided the most accurate prediction of emphysema. Conclusion Combining CT measures of lung density and emphysematous lesion size provides a more accurate estimate of lung surface area per unit lung volume than either measure alone. PMID:21040527

  11. Aerated concrete with mineral dispersed reinforcing additives

    NASA Astrophysics Data System (ADS)

    Berdov, G. I.; Ilina, L. V.; Mukhina, I. N.; Rakov, M. A.

    2015-01-01

    To guarantee the production of aerated concrete with the lowest average density while ensuring the required strength it is necessary to use a silica component with a surface area of 250-300 m2 / kg. The article presents experimental data on grinding the silica component together with clinker to the optimum dispersion. This allows increasing the strength of non-autoclaved aerated concrete up to 33%. Furthermore, the addition to aerated concrete the mixture of dispersed reinforcing agents (wollastonite, diopside) and electrolytes with multiply charged cations and anions (1% Fe2 (SO4)3; Al2 (SO4)3) provides the growth of aerated concrete strength at 30 - 75%. As a cohesive the clinker, crushed together with silica and mineral supplements should be used. This increases the strength of aerated concrete at 65% in comparing with Portland cement.

  12. Applying fine bubble aeration to small aeration tanks.

    PubMed

    Duchène, P; Cotteux, E; Capela, S

    2001-01-01

    Because the aeration system in an activated sludge plant typically represents a large part of the total energy requirements, designers and operators need accurate oxygen transfer information to make the aeration system as energy efficient as possible. This paper presents clean water tests performed at 38 wastewater treatment plants. The Specific Aeration Efficiency results (SAE, kgO2/kWh) are reported for: (1) large open channels (volume higher than 1000 m3), (2) small open channels, (3) total floor coverage cylindrical tanks, and (4) cylindrical tanks with a grid arrangement. Some practical guidelines can be drawn, some of them being: (1) high SAE can be achieved at small aeration tanks (< 1000 m3), applying cylindrical tanks with a total floor coverage arrangement of diffusers, volumetric blowers, and moderate air flow rates per diffuser area; (2) the high investment cost of this configuration can be justified with respect to a grid layout characterized by spiral liquid circulation which affects the oxygen transfer; (3) small open channels can meet sufficient SAE values but fail to meet in this range of tank volumes those of total floor coverage cylindrical tanks. PMID:11547985

  13. USING AERATION FOR CORROSION CONTROL

    EPA Science Inventory

    Aeration is a useful drinking water treatment process. Aeration has been used to remove hydrogen sulfide, methane, radon, iron, manganese, and volatile organic contaminants (VOCs) from drinking water. Aeration is also effective in removing carbon dioxide which directly impacts ...

  14. Aerator Placement Strategies

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The purpose of this study was to determine the effects on fish production, water quality and economics of concentrating paddlewheel aeration in large commercial ponds, compared to the current method of aerator placement. Ten 17-acre ponds (approximately 600 X 1300 ft) were brought into the study in ...

  15. Mechanical aerators' power and aeration control in bioreactors

    SciTech Connect

    Tarshish, M.; Arviv, R.; Aharoni, A.

    2000-04-01

    Mechanical aerators, used in many industrial plants for wastewater treatment, are the largest energy consumers in biological reactors. A number of aerators of equal or different power may be used with aeration control achieved by selecting appropriate working aerator combinations, and by changing aerators' submergence, provided by a control weir lift at the exit of reactors. Effective control may be implemented by selecting an adequate combination of working aerators and control weir lift for achieving the necessary oxygen demand. In this paper an approximate method is proposed for determining the characteristics of power characteristics of aerators under field conditions at different water levels in reactors, and on the use of known oxygen transfer rate under normal conditions and characteristics of weirs for water level control. Application of the proposed method has made it possible to obtain a mathematical model, which is used for the control of aeration in two biological reactors of Netanya Wastewater Treatment Works (Netanya, Israel).

  16. Measurements of Deposition, Lung Surface Area and Lung Fluid for Simulation of Inhaled Compounds

    PubMed Central

    Fröhlich, Eleonore; Mercuri, Annalisa; Wu, Shengqian; Salar-Behzadi, Sharareh

    2016-01-01

    Modern strategies in drug development employ in silico techniques in the design of compounds as well as estimations of pharmacokinetics, pharmacodynamics and toxicity parameters. The quality of the results depends on software algorithm, data library and input data. Compared to simulations of absorption, distribution, metabolism, excretion, and toxicity of oral drug compounds, relatively few studies report predictions of pharmacokinetics and pharmacodynamics of inhaled substances. For calculation of the drug concentration at the absorption site, the pulmonary epithelium, physiological parameters such as lung surface and distribution volume (lung lining fluid) have to be known. These parameters can only be determined by invasive techniques and by postmortem studies. Very different values have been reported in the literature. This review addresses the state of software programs for simulation of orally inhaled substances and focuses on problems in the determination of particle deposition, lung surface and of lung lining fluid. The different surface areas for deposition and for drug absorption are difficult to include directly into the simulations. As drug levels are influenced by multiple parameters the role of single parameters in the simulations cannot be identified easily. PMID:27445817

  17. The effect of aeration and non-aeration time on simultaneous organic, nitrogen and phosphorus removal using an intermittent aeration membrane bioreactor.

    PubMed

    Ujang, Z; Salim, M R; Khor, S L

    2002-01-01

    A laboratory-scale membrane bioreactor (MBR) was fed with synthetic wastewater to investigate the possibility of simultaneous removal of organic, nitrogen and phosphorus by intermittent aeration. The MBR consists of two compartments using a microfiltration membrane with 0.2 microm pore size and a surface area of 0.35 m2. Hydraulic retention time was set at 24 hours and solid retention time 25 days. MLSS concentration in the reactor was in the range of 2,500-3,800 mg/L. The MLSS internal recycling ratio was maintained at 100% influent flow rate. Intermittent aeration was applied in this study to provide an aerobic-anaerobic cycle. Three stages of operations were conducted to investigate the effect of aeration and non-aeration on simultaneous organic and nutrient removal. In Stage 1, time cycles of aeration and non-aeration were set at 90/150 min and 150/90 min in the first and second compartment, the removal efficiency was 97%, 94% and 70% for COD, nitrogen and phosphorus respectively. In Stage 2, time cycles of aeration and non-aeration were set at 60/120 min and 120/60 min in the first and second compartment, the removal efficiency was 97%, 96% and 71% for COD, nitrogen and phosphorus respectively. In Stage 3, time cycles of aeration and non-aeration were set at 120/120 min and 120/120 min in compartment 1 and 2, the removal efficiency was 98%, 96% and 78% for COD, nitrogen and phosphorus respectively. Results show that longer non-aeration time in the second compartment provided better performances of biological phosphorus removal. PMID:12448469

  18. Trends in Lung Cancer Incidence in a Healthcare Area.

    PubMed

    Molina, Antonio J; García-Martínez, Lidia; Zapata-Alvarado, Julio; Alonso-Orcajo, Nieves; Fernández-Villa, Tania; Martín, Vicente

    2015-11-01

    The aim of this study was to identify trends in the incidence of lung cancer in the Leon Healthcare Area. All cases of cancer among residents of the Leon healthcare catchment area listed in the hospital-based tumor registry of the Centro Asistencial Universitario de Leon (CAULE) between 1996 and 2010 were included. Gross incidence rates over 3-year intervals were calculated and adjusted for the worldwide and European populations. A total of 2,491 cases were included. In men, incidence adjusted for the European population rose from 40.1 new cases per 100,000 population (1996-1998) to 61.8 (2005-2007), and then fell to 54.6 (2008-2010). In women, incidence tripled from 3.0 (1996-1998) to 9.2 new cases per 100,000 (2008-2010). Although lung cancer is an avoidable disease, it is a serious problem in the Leon Healthcare Area. Of particular concern is the rising incidence among women. PMID:26153559

  19. Catfish production using intensive aeration

    Technology Transfer Automated Retrieval System (TEKTRAN)

    For the last 3 years, researchers at UAPB and NWAC have been monitoring and verifying production yields in intensively aerated catfish ponds with aeration rates greater than 6 hp/acre. We now have three years of data on commercial catfish production in intensively aerated ponds. With stocking densi...

  20. Costs of reservoir releases aeration

    SciTech Connect

    Lewis, A.R.; Bohac, C.E.

    1984-12-01

    Reservoir releases sometimes lack sufficient amounts of dissolved oxygen (DO) to assimilate wastes or to support aquatic life. Various types of aeration technology have been investigated, including turbine hub baffles, draft tube baffles, compressed air injected into the draft tube, compressed air injected through the headcover, and oxygen injected into the reservoir. To evaluate the feasibility of improving DO by various aeration techniques, TVA installed temporary aeration systems at several sites and conducted tests of their performance. Based on these experiments, TVA estimated the costs of installing and operating permanent aeration systems at several of its hydropower projects. This report describes the aeration alternatives investigated, documents current estimates of initial and annual costs for each alternative, and presents a general evaluation of the aeration methods based on their estimated costs and aeration capabilities.

  1. Landfill aeration worldwide: Concepts, indications and findings

    SciTech Connect

    Ritzkowski, M.; Stegmann, R.

    2012-07-15

    Highlights: Black-Right-Pointing-Pointer Different landfill aeration concepts and accordant application areas are described. Black-Right-Pointing-Pointer Examples of full scale projects are provided for Europe, North-America and Asia. Black-Right-Pointing-Pointer Major project findings are summarised, including prospects and limitations. Black-Right-Pointing-Pointer Inconsistencies between laboratory and full scale results have been elaborated. Black-Right-Pointing-Pointer An explanatory approach in connection with the inconsistencies is provided. - Abstract: The creation of sustainable landfills is a fundamental goal in waste management worldwide. In this connection landfill aeration contributes towards an accelerated, controlled and sustainable conversion of conventional anaerobic landfills into a biological stabilized state associated with a minimised emission potential. The technology has been successfully applied to landfills in Europe, North America and Asia, following different strategies depending on the geographical region, the specific legislation and the available financial resources. Furthermore, methodologies for the incorporation of landfill aeration into the carbon trade mechanisms have been developed in recent years. This manuscript gives an overview on existing concepts for landfill aeration; their application ranges and specifications. For all of the described concepts examples from different countries worldwide are provided, including details regarding their potentials and limitations. Some of the most important findings from these aeration projects are summarised and future research needs have been identified. It becomes apparent that there is a great demand for a systematisation of the available results and implications in order to further develop and optimise this very promising technology. The IWWG (International Waste Working Group) Task Group 'Landfill Aeration' contributes towards the achievement of this goal.

  2. Soil Aeration deficiencies in urban sites

    NASA Astrophysics Data System (ADS)

    Weltecke, Katharina; Gaertig, Thorsten

    2010-05-01

    root density and tree vigour on urban soils. For that purpose gas diffusivity, soil CO2 concentrations and fine root density were measured on typical urban sites in the German cities of Göttingen, Mannheim, and Kassel. The known characteristics of soil aeration on forest sites could be affirmed for urban soils. A negative correlation was found between gas diffusion coefficients and CO2 concentration as well as between fine root extension and CO2 concentration. Changes in crown structure of beech indicating a loss of vigour were found at sites with disturbed aeration. Diffusivity patterns and CO2 concentrations of different specific urban soil sealing types were found. On more natural sites (mulch, grass) increased gas diffusion and low CO2 concentration were present. In contrast, on more compacted or sealed areas (asphalt, paving stone, macadamised road surface) the exchange between soil air and atmosphere was nearly disconnected and soil CO2 concentrations partly exceeded the known critical value of 0.6 % up to tenfold. Literature Burton, A. J.; Pregitzer, K. S.; Zogg, G. P. und Zak D. R. (1997): Effect of measurement CO2 concentrations on sugar maple root respiration. In: Canadian journal of Forest Research, H. 17, S. 421-427. Gaertig, T. (2001): Bodengashaushalt, Feinwurzeln und Vitalität von Eichen. In: Freiburger Bodenkundliche Abhandlungen, H. 40, S. 157. Qi, J.; Marshall, J. D.; Mattson, K. G. (1994): High soil carbon dioxide concentrations inhibit root respiration of Douglas fir. In: New Phytol., Jg. 128, H. 3, S. 435-442. Schack-Kirchner, H.; Gaertig, T.; Wilpert, K. v.; Hildebrand, E. E. (2001): A modified McIntyre and Phillip approach to measure top-soil gas diffusivity in-situ. In: J. Plant Nutr. Soil Sci., Jg. 164, S. 253-258.

  3. Lung cancer care: the impact of facilities and area measures

    PubMed Central

    2015-01-01

    Lung cancer is the leading cause of cancer related mortality in the US, and while treatment disparities by race and class have been well described in the literature, the impact of social determinates of health, and specific characteristics of the treatment centers have been less well characterized. As the treatment of lung cancer relies more upon a precision and personalized medicine approach, where patients obtain treatment has an impact on outcomes and could be a major factor in treatment disparities. The purpose of this manuscript is to discuss the manner in which lung cancer care can be impacted by poor access to high quality treatment centers, and how the built environment can be a mitigating factor in the pursuit of treatment equity. PMID:26380179

  4. Lung cancer care: the impact of facilities and area measures.

    PubMed

    Lathan, Christopher S

    2015-08-01

    Lung cancer is the leading cause of cancer related mortality in the US, and while treatment disparities by race and class have been well described in the literature, the impact of social determinates of health, and specific characteristics of the treatment centers have been less well characterized. As the treatment of lung cancer relies more upon a precision and personalized medicine approach, where patients obtain treatment has an impact on outcomes and could be a major factor in treatment disparities. The purpose of this manuscript is to discuss the manner in which lung cancer care can be impacted by poor access to high quality treatment centers, and how the built environment can be a mitigating factor in the pursuit of treatment equity. PMID:26380179

  5. Dust and Fibrosis in the Lungs of Coal-Workers from the Wigan Area of Lancashire

    PubMed Central

    Spink, R.; Nagelschmidt, G.

    1963-01-01

    During the years 1953 to 1957 more than 1,000 lungs of coal-workers in the Wigan area were examined and compared with lungs from workers in South Wales. The Wigan lungs in general appeared to be less dusty and progressive massive fibrosis less frequent than in the South Wales lungs. Also, the more advanced cases of progressive massive fibrosis appeared to be of a silicotic type. Of these lungs, 100 were selected for study of the relation of the type and severity of pneumoconiosis to right ventricular hypertrophy, using Gough-Wentworth sections. The remaining tissues from 47 of these lungs were used for an analysis of the content and composition of the dust and its relation to the grade of fibrosis. The average coal and quartz percentages of the dust from the lungs in the Wigan area were similar to previous findings in lungs from the Cumberland coalfield but differed from those in South Wales where the lung dust has a higher coal and a lower quartz percentage. Two possible explanations for this finding are discussed. Images PMID:13990155

  6. Aeration equipment for small depths

    NASA Astrophysics Data System (ADS)

    Sluše, Jan; Pochylý, František

    2015-05-01

    Deficit of air in water causes complications with cyanobacteria mainly in the summer months. Cyanobacteria is a bacteria that produces poison called cyanotoxin. When the concentration of cyanobacteria increases, the phenomena "algal bloom" appears, which is very toxic and may kill all the organisms. This article describes new equipment for aeration of water in dams, ponds and reservoirs with small depth. This equipment is mobile and it is able to work without any human factor because its control is provided by a GPS module. The main part of this equipment consists of a floating pump which pumps water from the surface. Another important part of this equipment is an aerator where water and air are blended. Final aeration process runs in the nozzles which provide movement of all this equipment and aeration of the water. Simulations of the flow are solved by multiphase flow with diffusion in open source program called OpenFOAM. Results will be verified by an experiment.

  7. Lung deposited surface area size distributions of particulate matter in different urban areas

    NASA Astrophysics Data System (ADS)

    Kuuluvainen, Heino; Rönkkö, Topi; Järvinen, Anssi; Saari, Sampo; Karjalainen, Panu; Lähde, Tero; Pirjola, Liisa; Niemi, Jarkko V.; Hillamo, Risto; Keskinen, Jorma

    2016-07-01

    Lung deposited surface area (LDSA) concentration is considered as a relevant metric for the negative health effects of aerosol particles. We report for the first time the size distributions of the LDSA measured in urban air. The measurements were carried out in the metropolitan area of Helsinki, including mobile laboratory and stationary measurements in different outdoor environments, such as traffic sites, a park area, the city center and residential areas. The main instrument in this study was an electrical low pressure impactor (ELPI), which was calibrated in the field to measure the LDSA concentration. The calibration factor was determined to be 60 μm2/(cm3 pA). In the experiments, the LDSA size distributions were found to form two modes at the traffic sites and in the city center. Both of these traffic related particle modes, the nucleation mode and the soot mode, had a clear contribution to the total LDSA concentration. The average total concentrations varied from 12 to 94 μm2/cm3, measured in the park area and at the traffic site next to a major road, respectively. The LDSA concentration was found to correlate with the mass of fine particles (PM2.5), but the relation of these two metrics varied between different environments, emphasizing the influence of traffic on the LDSA. The results of this study provide valuable information on the total concentrations and size distributions of the LDSA for epidemiological studies. The size distributions are especially important in estimating the contribution of outdoor concentrations on the concentrations inside buildings and vehicles through size-dependent penetration factors.

  8. TECHNOLOGY ASSESSMENT OF FINE BUBBLE AERATORS

    EPA Science Inventory

    This technology assessment addresses design and evaluation of fine bubble aeration equipment. It discusses the associated gas transfer theory used as the basis for measuring water and wastewater oxygenation efficiency. Mixing requirements are also discussed. While bubble aeration...

  9. Experimental investigations of aeration efficiency in high-head gated circular conduits.

    PubMed

    Cihat Tuna, M; Ozkan, Fahri; Baylar, Ahmet

    2014-01-01

    The primary purpose of water aeration is to increase the oxygen saturation of the water. This can be achieved by using hydraulic structures because of substantial air bubble entrainment at these structures. Closed conduit aeration is a particular instance of this. While there has been a great deal of research on air-demand ratio within closed conduit, very little research has specifically addressed aeration efficiency of closed conduit. In the present work an experimental study was conducted to investigate the aeration efficiency of high-head gated circular conduits. Results showed that high-head gated circular conduits were effective for oxygen transfer. The effects of Froude number and ratio of the water cross-sectional flow area to the conduit cross-sectional area on aeration efficiency were particularly significant, whereas the effect of conduit length was only moderate. Further, a design formula for the aeration efficiency was presented relating the aeration efficiency to ratio of water cross-sectional flow area to conduit cross-sectional area and Froude number. The obtained results will be useful in future modeling processes and aid the practicing engineer in predicting aeration efficiency for design purposes. PMID:24647194

  10. Aeration-Induced Changes in Temperature and Nitrogen Dynamics in a Dimictic Lake.

    PubMed

    Holmroos, Heidi; Horppila, Jukka; Laakso, Sanna; Niemistö, Juha; Hietanen, Susanna

    2016-07-01

    Low levels of oxygen (O) in the hypolimnion layer of lakes are harmful to benthic animals and fish; they may also adversely affect nutrient cycles. Artificial aeration is often used in lake management to counteract these problems, but the effects of aeration on nitrogen (N) cycling are not known. We studied the effects of hypolimnetic aeration on N dynamics and temperature in a eutrophic lake by comparing continuous and pulsed aeration with a nonaerated station. Aeration decreased the accumulation of NH-N deep in the lake (20-33 m) by supplying O for nitrification, which in turn provided substrate for denitrification and promoted N removal. Aeration also increased the temperature in the hypolimnion. Denitrification rate was highest in the nonaerated deep areas (average, 7.62 mg N m d) due to very high rates during spring turnover of the water column, demonstrating that natural turnover provides O for nitrification. During stratification, denitrification was highest at the continuously aerated station (4.06 mg N m d) and lowest at the nonaerated station (3.02 mg N m d). At the periodically aerated station, aeration pauses did not restrict the increase in temperature but resulted in accumulation of NH-N and decreased the contribution of denitrification as a nitrate reduction process. Our findings demonstrate that hypolimnetic aeration can substantially affect N cycling in lakes and that the effect depends on the aeration strategy. Because N is one of the main nutrients controlling eutrophication, the effects of aeration methods on N removal should be considered as part of strategies to manage water quality in lakes. PMID:27380085

  11. Enhanced long-term organics and nitrogen removal and associated microbial community in intermittently aerated subsurface flow constructed wetlands.

    PubMed

    Fan, Jinlin; Zhang, Jian; Guo, Wenshan; Liang, Shuang; Wu, Haiming

    2016-08-01

    The long-term enhanced removal efficiency of organics and nitrogen in subsurface flow constructed wetlands (SSF CWs) with and without intermittent aeration for decentralized domestic wastewater was evaluated, and the function of intermittent aeration on microbial community was also investigated in this study. The high and long-term 95.6% COD, 96.1% NH4(+)-N and 85.8% TN removal efficiencies were achieved in experimental intermittently aerated SSF CW compared with non-aerated SSF CW. Aerated SSF CWs also exhibited the excellent removal performance when comparatively comparing with other strategies and techniques applied in CWs. In addition, fluorescence in situ hybridization (FISH) analysis revealed that associated microbial abundance significantly increased owing to intermittent aeration. These results indicated intermittent aeration CWs might be an effective and sustainable strategy for wastewater treatment in rural areas, but require further full-scale investigation in future. PMID:27246456

  12. OXYGEN AERATION AT NEWTOWN CREEK

    EPA Science Inventory

    A successful initial feasibility investigation of oxygen aeration at the 0.11-cu m/sec (2.5-mgd) municipal wastewater treatment plant in Batavia, New York, prompted a larger demonstration at New York City's 13.6-cu m/sec (310-mgd) Newtown Creek Plant. A 34-mo evaluation was perfo...

  13. Structural properties of autoclaved aerated concrete masonry

    SciTech Connect

    Matthys, J.H.; Nelson, R.L.

    1999-07-01

    Autoclaved aerated concrete masonry units are manufactured from portland cement, quartz sand, water, lime, gypsum and a gas forming agent. The units are steam cured under pressure in an autoclave transforming the material into a hard calcium silicate. The autoclaved aerated concrete masonry units are large-size solid rectangular prisms which are laid using thin-bed mortar layers into masonry assemblages. The system and product are not new--patented in 1924 by Swedish architect Johan Eriksson. Over a period of 60 years this product has been used in all areas of residential and industrial construction and in virtually all climates. However, the principal locations of application have been generally outside the US Little information in the US is available on the structural properties of this product. Due to the interest in use of this product in the construction industry and the construction of production plants in the US, the Construction Research Center at the University of Texas at Arlington and Robert L. Nelson & Associates conducted a series of tests to determine some of the basic structural properties of this product. This paper presents the findings of those investigations.

  14. Aeration for plant root respiration in a tidal marsh

    NASA Astrophysics Data System (ADS)

    Li, Hailong; Li, Ling; Lockington, David

    2005-06-01

    This paper investigates the tidal effects on aeration conditions for plant root respiration in a tidal marsh. We extend the work of Ursino et al. (2004) by using a two-phase model for air and water flows in the marsh. Simulations have been conducted to examine directly the link between the airflow dynamics and the aeration condition in the marsh soil. The results show that the effects of entrapped air on water movement in the vadose zone are significant in certain circumstances. Single-phase models based on Richards' equation, which neglect such effects, may not be adequate for quantifying the aeration condition in tidal marsh. The optimal aeration condition, represented by the maximum of the integral magnitude of tidally advected air mass (TAAM) flux, is found to occur near the tidal creek for the four soil textures simulated. This may explain the observation that some salt marsh plant species grow better near tidal creeks than in the inner marsh areas. Our analyses, based on the two-phase model and predicted TAAM flux magnitude, provide further insight into the "positive feedback" mechanism proposed by Ursino et al. (2004). That is, pioneer plants may grow successfully near the creek where the root aeration condition is optimal. The roots of the pioneer plants can soften and loosen the rhizosphere soil, which increases the evapotranspiration rate, the soil porosity, and absolute permeability and weakens the capillary effects. These, in turn, improve further the root aeration conditions and may lead to colonization by plants less resistant to anaerobic conditions.

  15. Aeration for plant root respiration in a tidal marsh

    NASA Astrophysics Data System (ADS)

    Li, Hailong; Li, Ling; Lockington, David

    2005-06-01

    This paper investigates the tidal effects on aeration conditions for plant root respiration in a tidal marsh. We extend the work of Ursino et al. (2004) by using a two-phase model for air and water flows in the marsh. Simulations have been conducted to examine directly the link between the airflow dynamics and the aeration condition in the marsh soil. The results show that the effects of entrapped air on water movement in the vadose zone are significant in certain circumstances. Single-phase models based on Richards' equation, which neglect such effects, may not be adequate for quantifying the aeration condition in tidal marsh. The optimal aeration condition, represented by the maximum of the integral magnitude of tidally advected air mass (TAAM) flux, is found to occur near the tidal creek for the four soil textures simulated. This may explain the observation that some salt marsh plant species grow better near tidal creeks than in the inner marsh areas. Our analyses, based on the two-phase model and predicted TAAM flux magnitude, provide further insight into the ``positive feedback'' mechanism proposed by Ursino et al. (2004). That is, pioneer plants may grow successfully near the creek where the root aeration condition is optimal. The roots of the pioneer plants can soften and loosen the rhizosphere soil, which increases the evapotranspiration rate, the soil porosity, and absolute permeability and weakens the capillary effects. These, in turn, improve further the root aeration conditions and may lead to colonization by plants less resistant to anaerobic conditions.

  16. Renewable energy for the aeration of wastewater ponds.

    PubMed

    Hobus, I; Hegemann, W

    2003-01-01

    The application of a decentralised renewable energy supply for the aeration of wastewater ponds, and the influence of an unsteady oxygen supply on the specific conversion rate and biocoenose was investigated. With the discontinuous aeration the specific conversion rate is increased as compared to facultative ponds. The estimation of the microorganisms consortia was done with in situ hybridisation techniques. A significant shift in the bacteria population with the chosen specific probes for anaerobic, sulphate reducing and nitrifying bacteria could not be detected. Wastewater ponds have sufficient buffer volume to compensate for the fluctuating energy supply. But the efficiency of the energy supply of a photovoltaic plant decreases in shallow lakes (d < 1.5 m) corresponding to a high oxygen production of algae. For the layout of the individual components: photovoltaic and wind power plant, energy management, aeration system and wastewater pond, a simulation model was developed and tested. The application of renewable energy for the aeration of wastewater ponds is a useful alternative for the redevelopment of overloaded ponds as well as the construction of new wastewater ponds, especially in areas with an inadequate central electricity grid and a high availability of wind and solar energy. PMID:14510232

  17. Gravity effects on upper airway area and lung volumes during parabolic flight.

    PubMed

    Beaumont, M; Fodil, R; Isabey, D; Lofaso, F; Touchard, D; Harf, A; Louis, B

    1998-05-01

    We measured upper airway caliber and lung volumes in six normal subjects in the sitting and supine positions during 20-s periods in normogravity, hypergravity [1.8 + head-to-foot acceleration (Gz)], and microgravity ( approximately 0 Gz) induced by parabolic flights. Airway caliber and lung volumes were inferred by the acoustic reflection method and inductance plethysmography, respectively. In subjects in the sitting position, an increase in gravity from 0 to 1. 8 +Gz was associated with increases in the calibers of the retrobasitongue and palatopharyngeal regions (+20 and +30%, respectively) and with a concomitant 0.5-liter increase in end-expiratory lung volume (functional residual capacity, FRC). In subjects in the supine position, no changes in the areas of these regions were observed, despite significant decreases in FRC from microgravity to normogravity (-0.6 liter) and from microgravity to hypergravity (-0.5 liter). Laryngeal narrowing also occurred in both positions (about -15%) when gravity increased from 0 to 1.8 +Gz. We concluded that variation in lung volume is insufficient to explain all upper airway caliber variation but that direct gravity effects on tissues surrounding the upper airway should be taken into account. PMID:9572811

  18. Collapsed Lung

    MedlinePlus

    A collapsed lung happens when air enters the pleural space, the area between the lung and the chest wall. If it is a total collapse, it is called pneumothorax. If only part of the lung is affected, ...

  19. Collapsed Lung

    MedlinePlus

    A collapsed lung happens when air enters the pleural space, the area between the lung and the chest wall. If it is a ... is called pneumothorax. If only part of the lung is affected, it is called atelectasis. Causes of ...

  20. High performance aerated lagoon systems

    SciTech Connect

    Rich, L.

    1999-08-01

    At a time when less money is available for wastewater treatment facilities and there is increased competition for the local tax dollar, regulatory agencies are enforcing stricter effluent limits on treatment discharges. A solution for both municipalities and industry is to use aerated lagoon systems designed to meet these limits. This monograph, prepared by a recognized expert in the field, provides methods for the rational design of a wide variety of high-performance aerated lagoon systems. Such systems range from those that can be depended upon to meet secondary treatment standards alone to those that, with the inclusion of intermittent sand filters or elements of sequenced biological reactor (SBR) technology, can also provide for nitrification and nutrient removal. Considerable emphasis is placed on the use of appropriate performance parameters, and an entire chapter is devoted to diagnosing performance failures. Contents include: principles of microbiological processes, control of algae, benthal stabilization, design for CBOD removal, design for nitrification and denitrification in suspended-growth systems, design for nitrification in attached-growth systems, phosphorus removal, diagnosing performance.

  1. COMPUTER AIDED DESIGN OF DIFFUSED AERATION SYSTEMS

    EPA Science Inventory

    CADDAS (Computer Aided Design of Diffused Aeration Systems) is a microcomputer-based program that analyzes the cost and performance of diffused aeration used in activated sludge wastewater treatment systems. The program can analyze both coarse bubble and fine pore diffusers as we...

  2. PERFORMANCE OF AERATED LAGOONS IN NORTHERN CLIMATES

    EPA Science Inventory

    Studies of cold climate aerated lagoons conducted by the Arctic Environmental Research Station, Fairbanks, Alaska are reported. Conclusions are based on these studies, observations of full scale aerated lagoons operating in Alaska and reports on lagoons in the northern tier of th...

  3. Impact of post-infiltration soil aeration at different growth stages of sub-surface trickle-irrigated tomato plants

    NASA Astrophysics Data System (ADS)

    Li, Yuan; Jia, Zong-xia; Niu, Wen-Quan; Wang, Jing-wei

    2016-07-01

    Sensitivity to low rhizosphere soil aeration may change over time and therefore plant response may also depend on different growth stages of a crop. This study quantified effects of soil aeration during 5 different periods, on growth and yield of trickle-irrigated potted single tomato plants. Irrigation levels were 0.6 to 0.7 (low level) or 0.7 to 0.8 (high level) of total water holding capacity of the pots. Soil was aerated by injecting 2.5 l of air into each pot through the drip tubing immediately after irrigation. Fresh fruit yield, above ground plant dry weight, plant height, and leaf area index response to these treatments were measured. For all these 4 response variables, means of post-infiltration aeration between 58 to 85 days after sowing were 13.4, 43.5, 13.7, and 37.7% higher than those for the non-aerated pots, respectively. The results indicated that: post-infiltration soil aeration can positively impact the yield and growth of sub-surface trickle-irrigated potted tomato plants; positive effects on plant growth can be obtained with aeration during the whole growth period or with aeration for partial periods; positive growth effects of partial periods of aeration appears to persist and result in yield benefit.

  4. [Removal nitrogen of integrated vertical-flow constructed wetland under aeration condition].

    PubMed

    Tao, Min; He, Feng; Xu, Dong; Zhou, Qiao-Hong; Liang, Wei; Chen, Shui-Ping; Wu, Zhen-Bin

    2011-03-01

    Oxygen is an important limit factor of nitrogen removal in constructed wetlands, so it is the key point for improving nitrogen removal efficiency of constructed wetlands that the optimization of oxygen distribution within wetlands. Therefore, oxygen status, nitrogen removal and purification mechanism of integrated vertical-flow constructed wetland (IVCW) under aeration condition in summer and winter have been studied. The results showed that both oxygen levels and aerobic zones were increased in the wetland substrates. The area of oxic zone I (expressing with depth) extended from 22 cm, 17 cm to 53 cm, 44 cm, in summer and winter, respectively. The electric potential (Eh) profiling demonstrated that artificial aeration maintained the pattern of sequential oxic-anoxic-oxic (O-A-O) redox zones within the aerated IVCW in winter, while only two oxic-anoxic (O-A) zones were present inside the non-aerated IVCW in the cold season. The decomposition of organic matter and nitrification were obviously enhanced by artificial aeration since the removal efficiency of COD, TN and NH4(+) -N were increased by 12.2%, 6.9% and 15.1% in winter, respectively. There was no significant accumulation of NO3(-) -N in the effluent with an aeration cycle of 8 h on and 16 h off in this experiment. Moreover, we found that oxic zone I was the main region of pollutants removal in IVCW system, and artificial aeration mainly acted to enhance the purification capacity of this oxic zone in the aerated IVCW. These results suggest that aeration is important for optimization and application of IVCW system. PMID:21634169

  5. Landfill aeration for emission control before and during landfill mining.

    PubMed

    Raga, Roberto; Cossu, Raffaello; Heerenklage, Joern; Pivato, Alberto; Ritzkowski, Marco

    2015-12-01

    The landfill of Modena, in northern Italy, is now crossed by the new high velocity railway line connecting Milan and Bologna. Waste was completely removed from a part of the landfill and a trench for the train line was built. With the aim of facilitating excavation and further disposal of the material extracted, suitable measures were defined. In order to prevent undesired emissions into the excavation area, the aerobic in situ stabilisation by means of the Airflow technology took place before and during the Landfill Mining. Specific project features involved the pneumatic leachate extraction from the aeration wells (to keep the leachate table low inside the landfill and increase the volume of waste available for air migration) and the controlled moisture addition into a limited zone, for a preliminary evaluation of the effects on process enhancement. Waste and leachate were periodically sampled in the landfill during the aeration before the excavation, for quality assessment over time; the evolution of biogas composition in the landfill body and in the extraction system for different plant set-ups during the project was monitored, with specific focus on uncontrolled migration into the excavation area. Waste biological stability significantly increased during the aeration (waste respiration index dropped to 33% of the initial value after six months). Leachate head decreased from 4 to 1.5m; leachate recirculation tests proved the beneficial effects of moisture addition on temperature control, without hampering waste aerobization. Proper management of the aeration plant enabled the minimization of uncontrolled biogas emissions into the excavation area. PMID:26445364

  6. Bilateral Shoulder Dysfunction Related to the Lung Resection Area After Thoracotomy

    PubMed Central

    Miranda, Aline P. Bonato; de Souza, Hugo C. Dutra; Santos, Bruna Frequete Almeida; Abrã o, João; Cipriano, Federico Garcia; de Oliveira, Anamaria Siriani; Gastaldi, Ada C.

    2015-01-01

    Abstract This study aimed to investigate the mobility, pain, and disability of the shoulders after different pulmonary surgical procedures. It is a cross-sectional prospective study. A total of 38 patients who underwent lung surgery via thoracotomy (mean age = 57 ± 10 years) were evaluated in the preoperative period, and first and second postoperative days were assessed for range of motion of shoulder; pain intensity; and application of the Shoulder Pain and Disability Index questionnaire. This study compared the 3 days of evaluation, and the subgroups according to the resection area (biopsy/nodulectomy, lung segmentectomy and lobectomy). There was a decrease of flexion (153° ± 16°–98° ± 23°), abduction (151° ± 20°–126° ± 38°), and increased Shoulder Pain and Disability Index (2.4–44.3) in the shoulder ipsilateral to surgery from the preoperative to the first postoperative day (P < 0.05). There was a greater loss of ipsilateral flexion and abduction in the lobectomy subgroup (P < 0.05), and decreased abduction of the contralateral shoulder in the lung segmentectomy and lobectomy subgroups (P < 0.05). After pulmonary surgery, there is bilateral impairment in shoulder range of motion, with greater limitation on ipsilateral shoulder, and larger resections. PMID:26554796

  7. DESIGN INFORMATION ON FINE PORE AERATION SYSTEMS

    EPA Science Inventory

    Field studies were conducted over several years at municipal wastewater treatment plants employing line pore diffused aeration systems. These studies were designed to produce reliable information on the performance and operational requirements of fine pore devices under process ...

  8. ENHANCED BIODEGRADATION THROUGH IN-SITU AERATION

    EPA Science Inventory

    This presentation provided an overview of enhanced aerobic bioremediation using in-situ aeration or venting. The following topics were covered: (1) Basic discussion on biodegradation and respiration testing; (2) Basic discussion on volatilization, rate-limited mass transport, an...

  9. TECHNOLOGY ASSESSMENT OF THE BIOLOGICAL AERATED FILTER

    EPA Science Inventory

    This technology assessment describes a recently developed biological wastewater treatment concept called the biological aerated filter (BAF)/Biocarbonne process and ddresses performance and operational characteristics, design approaches, and potential applications of that process...

  10. DESIGN MANUAL: FINE PORE AERATION SYSTEMS

    EPA Science Inventory

    This manual presents the best current practices for selecting, designing, operating, maintaining, and controlling fine pore aeration systems used in the treatment of municipal wastewater. It was prepared by the American Society of Civil Engineers Committee on Oxygen Transfer unde...

  11. Bedside lung ultrasound in the evaluation of acute decompensated heart failure.

    PubMed

    Leidi, Federica; Casella, Francesco; Cogliati, Chiara

    2016-06-01

    Dyspnea is a common presenting complaint in the emergency department (ED) and a leading cause of hospitalization in intensive care unit (ICU) and medical wards. Ultrasound (US) has traditionally been considered inadequate to explore the aerated lung. However, in the past 15 years LUS gained broader application, at least in part thanks to the interpretation of the artefacts generated by the interaction of US and lung structures/content. The total reflection of US beam occurring at the pleural level determines the artefactual image of the aerated lung: an homogenous 'foggy-like' picture under the pleural line. As the air content of the lungs decreases due to interstitial imbibition, deposition of collagen or presence of blood, vertical artefacts -arising from the pleural line and moving synchronously with the respiration- called B-lines appear. Multiple and bilateral B-lines identify the alveolar-interstitial syndrome (AIS). The most common cause of AIS is the wet lung: the more the congestion burden, the more the extent of the B-lines, which become confluent until the so-called white lung in case of pulmonary edema. Many studies showed a higher accuracy of LUS in diagnosing acute decompensated heart failure (ADHF) as compared to chest X-ray As recently shown, the integration of LUS to clinical assessment allow to differentiate cardiogenic dyspnea with sensitivity and specificity greater than 95 %. Moreover, LUS can easily detect pleural effusion -frequently present in ADHF-appearing as an anechoic area in the recumbent area of the thorax, delimited inferiorly by the diaphragmatic dome and superiorly by the aerated lung. PMID:26885846

  12. Effect of perfusate hematocrit on urea permeability-surface area in isolated dog lung

    SciTech Connect

    Parker, R.E.; Roselli, R.J.; Haselton, F.R.; Harris, T.R.

    1986-10-01

    Seven dog lower left lung lobes were statically inflated and perfused at a constant rate for each lobe with a perfusate in which the hematocrit was altered over a wide range. The permeability-surface area of urea was calculated from multiple indicator dilution curves using two separate injectates for each hematocrit level. One injectate contained only /sup 125/I-albumin as the vascular reference tracer and the other contained both /sup 51/Cr-erythrocytes and /sup 125/I-albumin as the vascular reference tracers; both contained (/sup 14/C)urea as the permeating tracer. The results strongly indicate that the phenomenon of erythrocyte trapping of urea does not affect the calculation of urea permeability-surface area product provided the appropriate albumin-erythrocyte composite reference tracer is utilized in its calculation.

  13. Feasibility Study: Home Telemonitoring for Patients With Lung Cancer in a Mountainous Rural Area

    PubMed Central

    Petitte, Trisha M.; Narsavage, Georgia L.; Chen, Yea-Jyh; Coole, Charles; Forth, Tara; Frick, Kevin D.

    2015-01-01

    Purpose/Objectives To explore the feasibility of rural home telemonitoring for patients with lung cancer. Design Exploratory, descriptive, observational. Setting Patient homes within a 75-mile radius of the study hospital in West Virginia. Sample 10 patients hospitalized with lung cancer as a primary or secondary-related diagnosis. Methods Data included referral and demographics, chart reviews, and clinical data collected using a HomMed telemonitor. Five patients received usual care after discharge; five had telemonitors set up at home for 14 days with daily phone calls for nurse coaching; mid- and end-study data were collected by phone and in homes through two months. Main Research Variables Enrollment and retention characteristics, physiologic (e.g., temperature, pulse, blood pressure, weight, O2 saturation) and 10 symptom datapoints, patient and family telemonitor satisfaction. Findings Of 45 referred patients, only 10 consented; 1 of 5 usual care and 3 of 5 monitored patients completed the entire study. Telemonitored data transmission was feasible in rural areas with high satisfaction; symptom data and physiologic data were inconsistent but characteristic of lung cancer. Conclusions Challenges included environment, culture, technology, and overall enrollment and retention. Physiologic and symptom changes were important data for nurse coaching on risks, symptom management, and clinician contact. Implications for Nursing Enrollment and retention in cancer research warrants additional study. Daily monitoring is feasible and important in risk assessment, but length of time to monitor signs and symptoms, which changed rapidly, is unclear. Symptom changes were useful as proxy indicators for physiologic changes, so risk outcomes may be assessable by phone for patient self-management coaching by nurses. PMID:24578075

  14. Association between vascular-poor area of primary tumors and epidermal growth factor receptor gene status in advanced lung adenocarcinoma.

    PubMed

    Togashi, Yosuke; Masago, Katsuhiro; Kubo, Takeshi; Fujimoto, Daichi; Sakamori, Yuichi; Nagai, Hiroki; Kim, Young Hak; Togashi, Kaori; Mishima, Michiaki

    2012-12-01

    Mutation of the epidermal growth factor receptor gene (EGFR mutation) is a very important marker in the treatment for non-small cell lung cancer. Since signaling from this receptor induces tumor-associated angiogenesis, we hypothesized that lung cancers with EGFR mutations tend to develop locally with increased angiogenesis. Thus, the association between vascular-poor area of primary tumors and EGFR status was retrospectively investigated in advanced lung adenocarcinomas. To assess vascular-poor area, contrast-enhanced computed tomography scans taken before initial treatment for lung cancer were analyzed, together with primary tumor location (peripheral or central) and size. We analyzed 178 patients with advanced lung adenocarcinoma. EGFR mutations were detected in 95 of the 178 patients (53.4 %). EGFR mutation was found to be significantly related to women (P = 0.0070), never-smokers (P < 0.0001), and tumors without vascular-poor area (P < 0.0001). Based on a multivariate analysis, presence of EGFR mutations was independently associated with never-smokers (P = 0.0046), lack of vascular-poor area (P = 0.0001), and tumor size >30 mm (P = 0.0080). EGFR mutations were found in 41 of 51 never-smokers without vascular-poor area (80.4 %), 19 of 36 never-smokers with vascular-poor area (52.8 %), 19 of 37 current or former-smokers without vascular-poor area (51.4 %), and 16 of 54 current or former-smokers with vascular-poor area (29.6 %). This study showed an association between vascular-poor area of primary tumors and EGFR status. As a consequence, evaluation using a combination of smoking status and vascular-poor area allows us to predict presence of EGFR mutations at a high frequency. PMID:22492281

  15. Reduction of VOC emissions from aeration basins using mobil hoods and circulating aeration

    SciTech Connect

    Zhu, Hongwei; Keener, T.C.; Bishop, P.L.

    1997-12-31

    As regulated under the Clean Air Act Amendments (CAAA) of 1990, Publicly Owned Treatment Works (POTWs) with large treatment capacities will be required to reduce their emissions of volatile organic hazardous air pollutants, primarily from the aeration basins. Previous studies indicate that circulating aeration may significantly reduce volatile organic compound (VOC) emissions, most of which are from the upstream portion of the aeration basin. Based on these findings, circulating aeration facilitated by partial tank covering using mobile hoods is proposed as an effective emission control strategy. Using this technology, less VOCs will be stripped into and concentrated in reduced amount of off-gases which can be efficiently treated by conventional control technologies. Compared with fixed rigid covers of aeration basins, mobile hoods are inexpensive to construct and easy to operate.

  16. Use of the electrical aerosol detector as an indicator of the surface area of fine particles deposited in the lung.

    PubMed

    Wilson, William E; Stanek, John; Han, Hee-Siew Ryan; Johnson, Tim; Sakurai, Hiromu; Pui, David Y H; Turner, Jay; Chen, Da-Ren; Duthie, Scott

    2007-02-01

    Because of recent concerns about the health effects of ultrafine particles and the indication that particle toxicity is related to surface area, we have been examining techniques for measuring parameters related to the surface area of fine particles, especially in the 0.003- to 0.5-microm size range. In an earlier study, we suggested that the charge attached to particles, as measured by a prototype of the Electrical Aerosol Detector (EAD, TSI Inc., Model 3070), was related to the 1.16 power of the mobility diameter. An inspection of the pattern of particle deposition in the lung as a function of particle size suggested that the EAD measurement might be a useful indicator of the surface area of particles deposited in the lung. In this study, we calculate the particle surface area (micrometer squared) deposited in the lung per cubic centimeter of air inhaled as a function of particle size using atmospheric particle size distributions measured in Minneapolis, MN, and East St. Louis, IL. The correlations of powers of the mobility diameter, Dx, were highest for X = 1.1-1.6 for the deposited surface area and for X = 1.25 with the EAD signal. This overlap suggested a correspondence between the EAD signal and the deposited surface area. The correlation coefficients of the EAD signal and particle surface area deposited in the alveolar and tracheobronchial regions of the lung for three breathing patterns are in the range of Pearson's r = 0.91-0.95 (coefficient of determination, R2 = 0.82-0.90). These statistical relationships suggest that the EAD could serve as a useful indicator of particle surface area deposited in the lung in exposure and epidemiologic studies of the human health effects of atmospheric particles and as a measure of the potential surface area dose for the characterization of occupational environments. PMID:17355082

  17. Effects of aeration on gamma irradiation of sewage sludge

    NASA Astrophysics Data System (ADS)

    Chu, Libing; Wang, Jianlong; Wang, Bo

    2010-08-01

    In this paper the effect of aeration on gamma irradiation of sewage sludge was investigated to examine the potential solubilization of solids in sewage sludge to ultimately reduce the solids volume for disposal. Results showed that aeration increased the effectiveness of gamma radiation. The efficiency of sludge solubilization with aeration was increased by around 25% compared to that without aeration at an irradiation dose of 2.5-9 kGy. The soluble protein, polysaccharide and humic (like) substance concentrations were higher under aerated conditions. With aeration the overall reaction appears to be oxidative as evidenced by the higher nitrate and nitrite ion concentrations in solution.

  18. Biopulsing: An in situ aeration remediation strategy

    SciTech Connect

    Gupta, H.S.; Marshall, T.R.

    1997-12-31

    In situ soil aeration is an accepted technology for remediation of soil and groundwater impacted with petroleum hydrocarbons and halogenated hydrocarbons. This technology was utilized for remediating soil and groundwater at an aerospace components manufacturing facility located in southern California, Soil and groundwater had been impacted at the facility from historical releases of petroleum and halogenated hydrocarbons. Innovations in remediation system design, installation and monitoring strategies are described in this paper. The following tasks were conducted; (1) evaluation of the extent of impacted soil and groundwater; (2) collection of site-specific data necessary to evaluate and implement an appropriate remediation system to address the hydrocarbon-impacted soil; and (3) design, installation and operation of an in situ aeration system for remediation of soil and groundwater. The in situ aeration system operates on the principles of bioventing. Air was injected weekly into the subsurface by a system of wells placed at selected locations in short pulses lasting several hours. Oxygen utilization in the subsurface was monitored using subsurface sensors. Subsurface oxygen utilization rates of up to 1.5 percent resulted in an estimate of mass reduction of 71 pounds of hydrocarbons. The concentration of halogenated hydrocarbons was reduced in groundwater following commencement of aeration was observed in subsequent sampling events. The contribution of vadose zone aeration in reducing the concentrations of halogenated hydrocarbons in groundwater is currently being evaluated.

  19. Lung cancer in never-smokers: a case-control study in a radon-prone area (Galicia, Spain).

    PubMed

    Torres-Durán, María; Ruano-Ravina, Alberto; Parente-Lamelas, Isaura; Leiro-Fernández, Virginia; Abal-Arca, José; Montero-Martínez, Carmen; Pena-Álvarez, Carolina; González-Barcala, Francisco Javier; Castro-Añón, Olalla; Golpe-Gómez, Antonio; Martínez, Cristina; Mejuto-Martí, María José; Fernández-Villar, Alberto; Barros-Dios, Juan Miguel

    2014-10-01

    The aim of the study was to assess the effect of residential radon exposure on the risk of lung cancer in never-smokers and to ascertain if environmental tobacco smoke modifies the effect of residential radon. We designed a multicentre hospital-based case-control study in a radon-prone area (Galicia, Spain). All participants were never-smokers. Cases had an anatomopathologically confirmed primary lung cancer and controls were recruited from individuals undergoing minor, non-oncological surgery. Residential radon was measured using alpha track detectors. We included 521 individuals, 192 cases and 329 controls, 21% were males. We observed an odds ratio of 2.42 (95% CI 1.45-4.06) for individuals exposed to ≥200 Bq·m(-3) compared with those exposed to <100 Bq·m(-3). Environmental tobacco smoke exposure at home increased lung cancer risk in individuals with radon exposure>200 Bq·m(-3). Individuals exposed to environmental tobacco smoke and to radon concentrations>200 Bq·m(-3) had higher lung cancer risk than those exposed to lower radon concentrations and exposed to environmental tobacco smoke. Residential radon increases lung cancer risk in never-smokers. An association between residential radon exposure and environmental tobacco smoke on the risk of lung cancer might exist. PMID:25034571

  20. Acid mine water aeration and treatment system

    DOEpatents

    Ackman, Terry E.; Place, John M.

    1987-01-01

    An in-line system is provided for treating acid mine drainage which basically comprises the combination of a jet pump (or pumps) and a static mixer. The jet pump entrains air into the acid waste water using a Venturi effect so as to provide aeration of the waste water while further aeration is provided by the helical vanes of the static mixer. A neutralizing agent is injected into the suction chamber of the jet pump and the static mixer is formed by plural sections offset by 90 degrees.

  1. Nucleotide excision repair genes and risk of lung cancer among San Francisco Bay Area Latinos and African Americans.

    PubMed

    Chang, Jeffrey S; Wrensch, Margaret R; Hansen, Helen M; Sison, Jennette D; Aldrich, Melinda C; Quesenberry, Charles P; Seldin, Michael F; Kelsey, Karl T; Kittles, Rick A; Silva, Gabriel; Wiencke, John K

    2008-11-01

    Few studies on the association between nucleotide excision repair (NER) variants and lung cancer risk have included Latinos and African Americans. We examine variants in 6 NER genes (ERCC2, ERCC4, ERCC5, LIG1, RAD23B and XPC) in association with primary lung cancer risk among 113 Latino and 255 African American subjects newly diagnosed with primary lung cancer from 1998 to 2003 in the San Francisco Bay Area and 579 healthy controls (299 Latinos and 280 African Americans). Individual single nucleotide polymorphism and haplotype analyses, multifactor dimensionality reduction (MDR) and principal components analysis (PCA) were performed to assess the association between 6 genes in the NER pathway and lung cancer risk. Among Latinos, ERCC2 haplotype CGA (rs238406, rs11878644, rs6966) was associated with reduced lung cancer risk [odds ratio (OR) of 0.65 and 95% confidence interval (CI): 0.44-0.97], especially among nonsmokers (OR = 0.29; 95% CI: 0.12-0.67). From MDR analysis, in Latinos, smoking and 3 SNPs (ERCC2 rs171140, ERCC5 rs17655 and LIG1 rs20581) together had a prediction accuracy of 67.4% (p = 0.001) for lung cancer. Among African Americans, His/His genotype of ERCC5 His1104Asp (rs17655) was associated with increased lung cancer risk (OR = 1.78; 95% CI: 1.09-2.91), and LIG1 haplotype GGGAA (rs20581, rs156641, rs3730931, rs20579 and rs439132) was associated with reduced lung cancer risk (OR = 0.61; 95% CI: 0.42-0.88). Our study suggests different elements of the NER pathway may be important in the different ethnic groups resulting either from different linkage relationship, genetic backgrounds and/or exposure histories. PMID:18709642

  2. Surfactant effects on alpha-factors in aeration systems.

    PubMed

    Rosso, Diego; Stenstrom, Michael K

    2006-04-01

    Aeration in wastewater treatment processes accounts for the largest fraction of plant energy costs. Aeration systems function by shearing the surface (surface aerators) or releasing bubbles at the bottom of the tank (coarse- or fine-bubble aerators). Surfactant accumulation on gas-liquid interfaces reduces mass transfer rates, and this reduction in general is larger for fine-bubble aerators. This study evaluates mass transfer effects on the characterization and specification of aeration systems in clean and process water conditions. Tests at different interfacial turbulence regimes show higher gas transfer depression for lower turbulence regimes. Contamination effects can be offset at the expense of operating efficiency, which is characteristic of surface aerators and coarse-bubble diffusers. Results describe the variability of alpha-factors measured at small scale, due to uncontrolled energy density. Results are also reported in dimensionless empirical correlations describing mass transfer as a function of physiochemical and geometrical characteristics of the aeration process. PMID:16549087

  3. [{sup 18}F]fluorodeoxyglucose Uptake Patterns in Lung Before Radiotherapy Identify Areas More Susceptible to Radiation-Induced Lung Toxicity in Non-Small-Cell Lung Cancer Patients

    SciTech Connect

    Petit, Steven F.; Elmpt, Wouter J.C. van; Oberije, Cary J.G.; Vegt, Erik; Dingemans, Anne-Marie C.; Lambin, Philippe; Dekker, Andre L.A.J.; De Ruysscher, Dirk

    2011-11-01

    received more than 2 Gy to 5 Gy increased. Therefore, the risk of RILT may be decreased by applying sophisticated radiotherapy techniques to avoid areas in the lung with high [{sup 18}F]FDG uptake.

  4. AERATION TO REMOVE VOLATILE ORGANIC COMPOUNDS FROM GROUND WATER

    EPA Science Inventory

    The interim report presents general information on the use of aeration to remove volatile organic compounds from drinking water for public health reasons. The report illustrates the types of aerators, shows where they are being used, presents a means of estimating aeration perfor...

  5. T.A. BROWN MECHANICAL AERATOR

    EPA Science Inventory

    Students in the Environmental Engineering and Waster Resources capstone design class in the Department of Civil and Environmental Engineering will undertake a project in conjunction with Serasih Indonesia to develop a prototype mechanical aerator to be used in aquaculture live...

  6. NUMERICAL SIMULATION OF AERATED SLUDGE COMPOSTING

    EPA Science Inventory

    This report describes development of a time-dependent computerized model for composting of wastewater treatment plant sludge with forced aeration of the pile. The work was undertaken because, in the past, development of the composting process for wastewater sludge has been almost...

  7. Lung Cancer Attributable to Indoor Radon Exposures in Two Radon--Prone Areas, Stei (Romania) and Torrelodones (Spain)

    SciTech Connect

    Dinu, Alexandra; Cosma, Constantin; Vasiliniuc, Stefan; Sainz, Carlos; Poncela, Luis Santiago Quindos

    2009-05-22

    Radon and radon progeny are present indoors, in houses and others dwellings, representing the most important contribution to dose from natural sources of radiation. Most studies have demonstrated an increased risk of lung cancer at high concentration of radon for both smokers and nonsmokers. For medium and low concentrations which are the typical residential radon levels, recent researches have also demonstrated increased risks of lung cancer for people exposed. The work presents a comparative analysis of the radon exposure data in the two radon--prone areas, Stei, Transylvania, (Romania), in the near of old Romanian uranium mines and in the granitic area of Torrelodones town, Sierra de Guadarrama (Spain). One important difference between the two studied areas is related to the houses built using uranium waste as construction material in Stei area. Measurements of indoor radon were performed in 280 dwellings (Romania) and 91 dwellings (Spain) by using nuclear track detectors, CR 39. The highest value measured in Stei area was 2650 Bq{center_dot}m{sup -3}. and 366 Bq{center_dot}m{sup -3} in the Spanish region. The results are compute with the BEIR VI report estimates using the age-duration model at an exposure rate below 2650 Bq{center_dot}m{sup -3}. A total of 233 lung cancer deaths were calculated in the Stei area for a period of 13 years (1994-2006), which is 116.82% higher than observed from the national statistics. In comparison, in Torrelodones area, a number of 276 deaths caused by lung cancer were estimated along a period of 13 years, which is 2.09 times higher than the number observed by authorities. This represents a significantly evidence that elevated risk can strongly be associated with cumulated radon exposure.

  8. Lung Cancer Attributable to Indoor Radon Exposures in Two Radon—Prone Areas, Ştei (Romania) and Torrelodones (Spain)

    NASA Astrophysics Data System (ADS)

    Dinu, Alexandra; Cosma, Constantin; Sainz, Carlos; Poncela, Luis Santiago Quindós; Vasiliniuc, Ştefan

    2009-05-01

    Radon and radon progeny are present indoors, in houses and others dwellings, representing the most important contribution to dose from natural sources of radiation. Most studies have demonstrated an increased risk of lung cancer at high concentration of radon for both smokers and nonsmokers. For medium and low concentrations which are the typical residential radon levels, recent researches have also demonstrated increased risks of lung cancer for people exposed. The work presents a comparative analysis of the radon exposure data in the two radon—prone areas, Ştei, Transylvania, (Romania), in the near of old Romanian uranium mines and in the granitic area of Torrelodones town, Sierra de Guadarrama (Spain). One important difference between the two studied areas is related to the houses built using uranium waste as construction material in Ştei area. Measurements of indoor radon were performed in 280 dwellings (Romania) and 91 dwellings (Spain) by using nuclear track detectors, CR 39. The highest value measured in Ştei area was 2650 Bqṡm-3. and 366 Bqṡm-3 in the Spanish region. The results are compute with the BEIR VI report estimates using the age-duration model at an exposure rate below 2650 Bqṡm-3. A total of 233 lung cancer deaths were calculated in the Ştei area for a period of 13 years (1994-2006), which is 116.82% higher than observed from the national statistics. In comparison, in Torrelodones area, a number of 276 deaths caused by lung cancer were estimated along a period of 13 years, which is 2.09 times higher than the number observed by authorities. This represents a significantly evidence that elevated risk can strongly be associated with cumulated radon exposure.

  9. Familial aggregation of lung cancer in a high incidence area in China

    PubMed Central

    Jin, Y T; Xu, Y C; Yang, R D; Huang, C F; Xu, C W; He, X Z

    2005-01-01

    To investigate whether lung cancer clusters in families in a high incidence county of China, an analysis was conducted using data on domestic fuel history and tobacco use for family members of 740 deceased lung cancer probands and 740 controls (probands' spouses). Lung cancer prevalence was compared among first-degree relatives of probands and of controls, taking into account various factors using logistic regression and generalised estimating equations. First-degree relatives of probands, compared with those of controls, showed an excess risk of lung cancer (odds ratio (OR)=2.05, 95% confidence interval (CI): 1.68–2.53). Overall, female relatives of probands had a greater risk than did their male counterparts, and the risk was 2.90-fold for parents of probands as compared with parents of spouses. Female relatives of probands had 2.67-fold greater risk than female controls. Lung cancer risk was particularly marked among mothers (OR=3.78, 95% CI: 2.03–7.12). Having two or more affected relatives was associated with a 2.69–5.40-fold risk increase. The risk elevation was also found for other cancers overall. Results confirm previous findings of a genetic predisposition to lung cancer, and also imply that lung cancer may share a genetic background with other cancers. PMID:15756270

  10. Lifetime risk of urothelial carcinoma and lung cancer in the arseniasis-endemic area of Northeastern Taiwan

    NASA Astrophysics Data System (ADS)

    Yang, Tse-Yen; Hsu, Ling-I.; Chen, Hui-Chi; Chiou, Hung-Yi; Hsueh, Yu-Mei; Wu, Meei-Maan; Chen, Chi-Ling; Wang, Yuan-Hung; Liao, Ya-Tang; Chen, Chien-Jen

    2013-11-01

    Arsenic in drinking water has been shown to increase the risk of urothelial carcinoma and lung cancer. However, the lifetime risk of developing urothelial carcinoma and lung cancer caused by exposure to arsenic in drinking water has not been reported. This study aimed to assess the lifetime risk of urothelial carcinoma and lung cancer caused by arsenic exposure from drinking water and cigarette smoking habit for residents living in the arseniasis-endemic area in Northeastern Taiwan. We recruited 8086 residents in 1991-1994 and monitored them for their newly developed types of cancers, identified by computerized linkage with the national cancer registry profile. There were 37 newly diagnosed urothelial carcinoma cases and 223 new lung cancer cases during the follow-up period (until 2007). The lifetime (35-85 years old) cumulative risk of developing urothelial carcinoma from an arsenic concentration in the drinking water of <10, 10-99, and 100+ μg/L was 0.29%, 1.07% and 3.43%, respectively. The corresponding probabilities were 7.42%, 8.99% and 17.09% for the lifetime risk of developing lung cancer. Cigarette smoking was associated with an increased risk of urothelial carcinoma and lung cancer, showing the hazard ratio (95% confidence interval) of 2.48 (1.27-4.82) and 3.44 (2.00-5.90) after adjusting for the arsenic concentration in drinking water. After adjusting for cigarette smoking, the hazard ratio (95% confidence interval) of developing urothelial carcinoma caused by the arsenic concentration in drinking water of <10, 10-99 and 100+ μg/L was 1.0 (the reference group), 2.18 (0.59-8.01), and 8.71 (2.49-30.48), respectively. The corresponding figures were 1.0 (the reference group), 1.14 (0.80-1.61), 1.84 (1.28-2.65) for lung cancer. Synergistic effects on the development of urothelial carcinoma and lung cancer existed between the arsenic exposure level and cigarette smoking. It is suggested that people who have had a high exposure to arsenic in drinking water

  11. Automated segmentation of lung airway wall area measurements from bronchoscopic optical coherence tomography imaging

    NASA Astrophysics Data System (ADS)

    Heydarian, Mohammadreza; Choy, Stephen; Wheatley, Andrew; McCormack, David; Coxson, Harvey O.; Lam, Stephen; Parraga, Grace

    2011-03-01

    Chronic Obstructive Pulmonary Disease (COPD) affects almost 600 million people and is currently the fourth leading cause of death worldwide. COPD is an umbrella term for respiratory symptoms that accompany destruction of the lung parenchyma and/or remodeling of the airway wall, the sum of which result in decreased expiratory flow, dyspnea and gas trapping. Currently, x-ray computed tomography (CT) is the main clinical method used for COPD imaging, providing excellent spatial resolution for quantitative tissue measurements although dose limitations and the fundamental spatial resolution of CT limit the measurement of airway dimensions beyond the 5th generation. To address this limitation, we are piloting the use of bronchoscopic Optical Coherence Tomography (OCT), by exploiting its superior spatial resolution of 5-15 micrometers for in vivo airway imaging. Currently, only manual segmentation of OCT airway lumen and wall have been reported but manual methods are time consuming and prone to observer variability. To expand the utility of bronchoscopic OCT, automatic and robust measurement methods are required. Therefore, our objective was to develop a fully automated method for segmenting OCT airway wall dimensions and here we explore several different methods of image-regeneration, voxel clustering and post-processing. Our resultant automated method used K-means or Fuzzy c-means to cluster pixel intensity and then a series of algorithms (i.e. cluster selection, artifact removal, de-noising) was applied to process the clustering results and segment airway wall dimensions. This approach provides a way to automatically and rapidly segment and reproducibly measure airway lumen and wall area.

  12. Aeration of groundwater at a superfund site

    SciTech Connect

    Connors, P.

    1992-07-01

    One of the promising environmental cleanup activities underway at Lawrence Livermore National Laboratory is remediation of groundwater pollution by aeration techniques at the laboratory`s Site 300. The treatment facility extracts groundwater from a shallow aquifer and contaminants are removed by spraying the water into one end of a trailer mounted, polyethylene air-sparging tank. As the water passes through the tank, it is subjected to vigorous aeration from a large blower. By the time the water reaches the other end of the sparging tank, it has been stripped of volatile organic compounds(VOCs). The VOCs are stripped into the air and then collected by passing the air through two in-series, granular, activated-carbon canisters.

  13. CFD model of an aerating hydrofoil

    NASA Astrophysics Data System (ADS)

    Scott, D.; Sabourin, M.; Beaulieu, S.; Papillon, B.; Ellis, C.

    2014-03-01

    Improving water quality in the tailrace below hydroelectric dams has become a priority in many river systems. In warm climates, water drawn by the turbine from deep in a reservoir can be deficient in dissolved oxygen (DO), a critical element in maintaining a healthy aquatic ecosystem. Many different solutions have been proposed in order to increase the DO levels in turbine discharge, including: turbine aeration systems (adding air to the water through either the turbine hub, the periphery or through distributed aeration in the runner blades); bubble diffusers in the reservoir or in the tailrace; aerating weirs downstream of the dams; and surface water pumps in the reservoir near the dam. There is a significant potential to increase the effectiveness of these solutions by improving the way that oxygen is introduced into the water; better distributions of bubbles will result in better oxygen transfer. In the present study, a two-phase Computational Fluid Dynamics model has been formulated using a commercial code to study the distribution of air downstream of a simple aerating hydrofoil. The two-phase model uses the Eulerian-Eulerian approach. Appropriate relations are used to model the interphase forces, including the Grace drag force model, the Favre averaged drag force and the Sato enhanced eddy viscosity. The model is validated using experimental results obtained in the water tunnel at the University of Minnesota's Saint Anthony Falls Laboratory. Results are obtained for water velocities between 5 and 10 m/s, air flow rates between 0.5 and 1.5 sL/min and for angles of attack between 0° and -8°. The results of this study show that the CFD model provides a good qualitative comparison to the experimental results by well predicting the wake location at the different flow rates and angles of attack used.

  14. Synthetic musk emissions from wastewater aeration basins.

    PubMed

    Upadhyay, Nabin; Sun, Qinyue; Allen, Jonathan O; Westerhoff, Paul; Herckes, Pierre

    2011-01-01

    Wastewater aeration basins at publicly owned treatment works (POTWs) can be emission sources for gaseous or aerosolized sewage material. In the present study, particle and gas phase emissions of synthetic musks from covered and uncovered aeration basins were measured. Galaxolide (HHCB), tonalide (AHTN), and celestolide (ADBI) were the most abundant, ranging from 6704 to 344,306 ng m(-3), 45-3816 ng m(-3), and 2-148 ng m(-3) in the gas phase with particle phase concentrations 3 orders of magnitude lower. The musk species were not significantly removed from the exhaust air by an odor control system, yielding substantial daily emission fluxes (∼ 200 g d(-1) for HHCB) into the atmosphere. However, simple dispersion modeling showed that the treatment plants are unlikely to be a major contributor to ambient air concentrations of these species. Emission of synthetic musk species during wastewater treatment is a substantial fate process; more than 14% of the influent HHCB is emitted to the atmosphere in a POTW as opposed to the <1% predicted by an octanol-water partition coefficient and fugacity-based US EPA fate model. The substantial atmospheric emission of these compounds is most likely due to active stripping that occurs in the aeration basins by bubbling air through the sludge. PMID:21122886

  15. Effects of aeration method and aeration rate on greenhouse gas emissions during composting of pig feces in pilot scale.

    PubMed

    Jiang, Tao; Li, Guoxue; Tang, Qiong; Ma, Xuguang; Wang, Gang; Schuchardt, Frank

    2015-05-01

    The aim of this study was to uncover ways to mitigate greenhouse gas (GHG) emissions and reduce energy consumption during the composting process. We assessed the effects of different aeration rates (0, 0.18, 0.36, and 0.54 L/(kg dry matter (dm)·min)) and methods (continuous and intermittent) on GHG emissions. Pig feces and corn stalks were mixed at a ratio of 7:1. The composting process lasted for 10 weeks, and the compost was turned approximately every 2 weeks. Results showed that both aeration rate and method significantly affected GHG emissions. Higher aeration rates increased NH3 and N2O losses, but reduced CH4 emissions. The exception is that the CH4 emission of the passive aeration treatment was lower than that of the low aeration rate treatment. Without forced aeration, the CH4 diffusion rates in the center of the piles were very low and part of the CH4 was oxidized in the surface layer. Intermittent aeration reduced NH3 and CH4 losses, but significantly increased N2O production during the maturing periods. Intermittent aeration increased the nitrification/denitrification alternation and thus enhanced the N2O production. Forced aeration treatments had higher GHG emission rates than the passive aeration treatment. Forced aeration accelerated the maturing process, but could not improve the quality of the end product. Compared with continuous aeration, intermittent aeration could increase the O2 supply efficiency and reduced the total GHG emission by 17.8%, and this reduction increased to 47.4% when composting was ended after 36 days. PMID:25968266

  16. Environmental Carcinogen Releases and Lung Cancer Mortality in Rural-Urban Areas of the United States

    ERIC Educational Resources Information Center

    Luo, Juhua; Hendryx, Michael

    2011-01-01

    Purpose: Environmental hazards are unevenly distributed across communities and populations; however, little is known about the distribution of environmental carcinogenic pollutants and lung cancer risk across populations defined by race, sex, and rural-urban setting. Methods: We used the Toxics Release Inventory (TRI) database to conduct an…

  17. Aeration apparatus for discharge control of particulate matter

    SciTech Connect

    Dirkse, H.A.; Dewitz, T.S.; Scott, A.M.

    1990-06-19

    This paper describes an apparatus for maintaining a uniform mass flow rate of a particulate solids and gas mixture discharged from a holding vessel to a receiving reactor. It comprises: means for introducing the mixture into a containing means, the containing means being located within the holding vessel and having a downwardly converging wall which forms at least one port at the apex thereof for discharging the mixture therefrom; first tubular aeration means fixedly secured within the containing means and in axial alignment with the discharge port for aerating the mixture; second aeration means fixedly secured to the first aeration means for aerating the mixture in a direction opposed to that of the first aeration means; first and second gaseous fluid supplies for providing gaseous fluids to the first and second aeration means respectively; first and second means for selectively injecting the gaseous fluids under pressure into the first and second aeration means; means, in the first and second aeration means, for discharging the gaseous fluids into the particulate solids and gas mixture; and means for discharging the particulate solids from the first containing means.

  18. Municipal sludge characteristic changes under different aerating condition in a deep-shaft aeration system.

    PubMed

    Xiong, Jiaqing; Wang, Xiaochang C; Shu, Wei; He, Teng; Liu, Yanzheng

    2016-01-01

    A pilot-scale municipal sewage sludge deep-shaft aeration system was implemented in Lanzhou, Gansu Province of China. The reactor depth was 60 m with a diameter of 1.0 m and the sludge to be treated came from a wastewater plant in Lanzhou. In order to obtain the optimum operation conditions, analysis was conducted on the transformations of the volatile suspended solids (VSS), temperature, pH, oxidation-reduction potential (ORP) and pathogens in the deep-shaft reactor under different aeration conditions. Attention was paid to how operating conditions affected the removal efficiency of the VSS and the reaction temperature. As a result, higher volatile solids removal was gained at higher temperature, and the temperature could reach 50.8°C for a complete inactivation of bacteria in the first reaction zone when the deep-shaft aeration system was run for about 18 days. The sludge aeration rate was observed as 1.5 to 1.8 L/(h·L sludge) which enabled the volatile solids removal rate to reach 40.1%. The degradation of VSS occurred under a micro-oxygen environment, and the lowest ORP was found to be -256 mV in the digestive process. Not only aerobic bacteria but also anaerobic and facultative bacteria performed their functions in the reactor. PMID:27054720

  19. [Independent lung ventilation for asymmetric injury: case report as a demonstration of common challenge].

    PubMed

    Lebedinskiĭ, K M; Artiukov, D A; Borisov, M V; Gromova, T A; Slivin, O A

    2014-01-01

    The article deals with a case of conventional mechanical ventilation in 75 y.o. woman with the background of uncompensated diabetes mellitus, suffering from bilateral pneumonia with predominantly left-sided lesion and severe sepsis. The conventional mechanical ventilation with high pressure levels led to arterial hypoxemia with P/F ratio 52. Independent lung ventilation immediately increased oxygenation up to P/F ratio 225 and evidently improved left lung aeration. The case demonstrates that while applying high pressures to open alveoli, we could not only provoke ventilator-induced lung injury and low cardiac output, but also "squeeze out" pulmonary perfusion from ventilated areas to non-ventilated ones with less intraalveolar pressure levels. PMID:25549491

  20. A retrospective study on malignant neoplasms of bladder, lung and liver in blackfoot disease endemic area in Taiwan.

    PubMed Central

    Chen, C. J.; Chuang, Y. C.; You, S. L.; Lin, T. M.; Wu, H. Y.

    1986-01-01

    A total of 69 bladder cancer, 76 lung cancer and 59 liver cancer deceased cases and 368 alive community controls group-matched on age and sex were studied to evaluate the association between high-arsenic artesian well water and cancers in the endemic area of blackfoot disease (BFD), a unique peripheral vascular disease related to continuous arsenic exposure. According to a standardized structured questionnaire, information on risk factors was obtained through proxy interview of the cases and personal interview of the controls. A positive dose-response relationship was observed between the exposure to artesian well water and cancers of bladder, lung and liver. The age-sex-adjusted odds ratios of developing bladder, lung and liver cancers for those who had used artesian well water for 40 or more years were 3.90, 3.39, and 2.67, respectively, as compared with those who never used artesian well water. Multiple binary logistic regression analyses showed that the dose-response relationships and odds ratios remained much the same while other risk factors were further adjusted. PMID:3964542

  1. Cancer of the lung, pleura, larynx and pharynx in an area with an asbestos-cement plant.

    PubMed

    Curin, K; Sarić, M

    1995-09-01

    Data on persons who died of cancer of the respiratory tract and pharynx in a Croatian coastal area with an asbestos-cement industry were collected and analysed for the period 1970-1990. Cancer mortality data were obtained from the Cancer Registry of Croatia. By the poll method, additional data on occupation, life style (smoking, alcohol drinking), length of residence in the area, educational level and cancer mortality among the relatives were obtained. The results of the investigation showed that the mortality rates for the lung, larynx and pharynx cancers, standardized according to age, were lower in the study area than expected (data for Croatia). Standardized mortality rates for mesothelioma were higher in the area under study for both sexes (except for women in the rural part of the area) than in Croatia. Within the study area the highest mortality rates for follow-up cancers were registered in the settlement where the asbestos-cement plant was located. Some settlements in two municipalities within the area also had higher mortality rates caused by these tumours in comparison with the rest of the study area or Croatia as a whole. In the evaluation of the obtained findings possible uneven distribution of emissions from the asbestos-cement plant caused by prevailing wind and air stream direction were considered. PMID:8645115

  2. Drill vessels float in aerated water

    SciTech Connect

    Hammett, D.S.

    1985-01-01

    Model tests, calculations, and case studies prove that a floating vessel will not sink due to gas reducing the water density in or adjacent to a subsea blowout. Several floating drill vessels have been lost as a result of subsea blowouts. Reports have circulated that the rig sank into something similar to a hole in the ocean caused by gas bubbles suspended in the water reducing its specific gravity. These erroneous reports, believed as truth by many people, have resulted in the modification of operations resulting in decreased safety. Several subsea well control operations have caused accidents and losses because the riser was not disconnected. This action was taken in fear of sinking in aerated water. The losses occurred because the vessel winched itself off the drill site to get away from the subsea well before disconnecting. Due to the high riser/BOP angle, the riser could not be disconnected and well control was later lost and the gas/oil flowed directly to the rig floor where massive fire/explosion damage occurred. If there had been a better understanding of water density, the rig personnel could have closed all hatches, shut-down all engines, disconnected the riser and released mooring lines at one end of the rig, and safely removed the rig out of the aerated water. This paper presents some of the technical data and references available which prove that a floating vessel will not sink due to loss of water density.

  3. Aeration control of thermophilic aerobic digestion using fluorescence monitoring.

    PubMed

    Kim, Young-Kee; Oh, Byung-Keun

    2009-01-01

    The thermophilic aerobic digestion (TAD) process is recognized as an effective method for rapid waste activated sludge (WAS) degradation and the deactivation of pathogenic microorganisms. Yet, high energy costs due to heating and aeration have limited the commercialization of economical TAD processes. Previous research on autothermal thermophilic aerobic digestion (ATAD) has already reduced the heating cost. However, only a few studies have focused on reducing the aeration cost. Therefore, this study applied a two-step aeration control strategy to a fill-and-draw mode semicontinuous TAD process. The NADH-dependent fluorescence was monitored throughout the TAD experiment, and the aeration rate shifted according to the fluorescence intensity. As a result, the simple two-step aeration control operation achieved a 20.3% reduction in the total aeration, while maintaining an effective and stable operation. It is also expected that more savings can be achieved with a further reduction of the lower aeration rate or multisegmentation of the aeration rate. PMID:19190414

  4. 21 CFR 880.6100 - Ethylene oxide gas aerator cabinet.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ethylene oxide gas aerator cabinet. 880.6100... Miscellaneous Devices § 880.6100 Ethylene oxide gas aerator cabinet. (a) Identification. An ethyene oxide gas... with a ventilation system designed to circulate and exchange the air in the cabinet to shorten the...

  5. 21 CFR 880.6100 - Ethylene oxide gas aerator cabinet.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ethylene oxide gas aerator cabinet. 880.6100... Miscellaneous Devices § 880.6100 Ethylene oxide gas aerator cabinet. (a) Identification. An ethyene oxide gas... with a ventilation system designed to circulate and exchange the air in the cabinet to shorten the...

  6. 21 CFR 880.6100 - Ethylene oxide gas aerator cabinet.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ethylene oxide gas aerator cabinet. 880.6100... Miscellaneous Devices § 880.6100 Ethylene oxide gas aerator cabinet. (a) Identification. An ethyene oxide gas... with a ventilation system designed to circulate and exchange the air in the cabinet to shorten the...

  7. 21 CFR 880.6100 - Ethylene oxide gas aerator cabinet.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide gas aerator cabinet. 880.6100... Miscellaneous Devices § 880.6100 Ethylene oxide gas aerator cabinet. (a) Identification. An ethyene oxide gas... with a ventilation system designed to circulate and exchange the air in the cabinet to shorten the...

  8. 21 CFR 880.6100 - Ethylene oxide gas aerator cabinet.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ethylene oxide gas aerator cabinet. 880.6100... Miscellaneous Devices § 880.6100 Ethylene oxide gas aerator cabinet. (a) Identification. An ethyene oxide gas... with a ventilation system designed to circulate and exchange the air in the cabinet to shorten the...

  9. OXIDATION OF AS(III) BY AERATION AND STORAGE

    EPA Science Inventory

    A study of the effects of aeration and storage on the oxidation of arsenic(III) was undertaken at three utilities in the US to establish the engineering significance of aeration as a potential pre-treatment method for arsenic removal. The results of this study clearly establish t...

  10. Effect of aeration of sediment on cadmium binding

    SciTech Connect

    Zhuang, Y.; Allen, H.E.; Fu, G. . Dept. of Civil Engineering)

    1994-05-01

    Acid-volatile sulfide (AVS) has been shown to be the dominant phase reacting with metals in anoxic sediments. The AVS in sediment decreases upon resuspension due to storm and dredging, and in winter when the rate of aeration processes exceeds that of the formation of sulfide. The authors conducted a series of lab aeration experiments in batch reactors to investigate the effects of aeration of sediment on the sulfide content of sediment and on the partitioning of cadmium, a model toxic metal, to the sediment. Aeration of sediment results in rapid decrease of the AVS. The authors studied the sediment characteristics for aeration periods of approximately a month. During this time, the concentrations of dissolved metals increased by 200 to 400% or more, relative to the concentrations present at the beginning of the test. The concentration of metal associated with AVS and with pyrite decreased. During the aeration, there are increases in the concentrations of hydrous iron and manganese oxides, and these materials become increasingly more important in the binding of cadmium. Following the aeration, > 50% of the cadmium was associated with the extractable iron and manganese components of the sediment. Overall, the binding capacity of the sediments for cadmium decreased after aeration.

  11. Enhancement of ultrasonic disintegration of sewage sludge by aeration.

    PubMed

    Zhao, He; Zhang, Panyue; Zhang, Guangming; Cheng, Rong

    2016-04-01

    Sonication is an effective way for sludge disintegration, which can significantly improve the efficiency of anaerobic digestion to reduce and recycle use of sludge. But high energy consumption limits the wide application of sonication. In order to improve ultrasonic sludge disintegration efficiency and reduce energy consumption, aeration was introduced. Results showed that sludge disintegration efficiency was improved significantly by combining aeration with ultrasound. The aeration flow rate, gas bubble size, ultrasonic density and aeration timing had impacts on sludge disintegration efficiency. Aeration that used in later stage of ultrasonic irradiation with low aeration flow rate, small gas bubbles significantly improved ultrasonic disintegration sludge efficiency. At the optimal conditions of 0.4 W/mL ultrasonic irradiation density, 30 mL/min of aeration flow rate, 5 min of aeration in later stage and small gas bubbles, ultrasonic sludge disintegration efficiency was increased by 45% and one third of ultrasonic energy was saved. This approach will greatly benefit the application of ultrasonic sludge disintegration and strongly promote the treatment and recycle of wastewater sludge. PMID:27090707

  12. FOULING OF FINE PORE DIFFUSED AERATORS: AN INTERPLANT COMPARISON

    EPA Science Inventory

    There has been increasing interest in fine pore aeration systems, along with concerned about diffuser fouling and the subsequent loss of aeration efficiency. he objective of this study was to assess the relative fouling tendency of fine bubble diffusers t nine activated sludge tr...

  13. FOULING OF FINE PORE DIFFUSED AERATORS: AN INTER- PLANT COMPARISON

    EPA Science Inventory

    There has been increasing interest in fine pore aeration systems, along with concerned about diffuser fouling and the subsequent loss of aeration efficiency. The objective of this study was to assess the relative fouling tendency of fine bubble diffusers t nine activated sludge ...

  14. Recirculation-aeration: Bibliography for aquaculture. Bibliographies and literature of agriculture (Final)

    SciTech Connect

    Perschbacher, P.W.; Powell, R.V.; Freeman, D.W.; Lorio, W.J.; Hanfman, D.T.

    1993-08-01

    The bibliography includes literature citations through 1992 related to water recirculation and aeration in aquaculture. The focus is on filtration, aeration, and circulation techniques in various aquaculture situations.

  15. Effects of Aeration Cycles on Nitrifying Bacterial Populations and Nitrogen Removal in Intermittently Aerated Reactors

    PubMed Central

    Mota, Cesar; Head, Melanie A.; Ridenoure, Jennifer A.; Cheng, Jay J.; de los Reyes, Francis L.

    2005-01-01

    The effects of the lengths of aeration and nonaeration periods on nitrogen removal and the nitrifying bacterial community structure were assessed in intermittently aerated (IA) reactors treating digested swine wastewater. Five IA reactors were operated in parallel with different aeration-to-nonaeration time ratios (ANA). Populations of ammonia-oxidizing bacteria (AOB) and nitrite-oxidizing bacteria (NOB) were monitored using 16S rRNA slot blot hybridizations. AOB species diversity was assessed using amoA gene denaturant gradient gel electrophoresis. Nitrosomonas and Nitrosococcus mobilis were the dominant AOB and Nitrospira spp. were the dominant NOB in all reactors, although Nitrosospira and Nitrobacter were also detected at lower levels. Reactors operated with the shortest aeration time (30 min) showed the highest Nitrosospira rRNA levels, and reactors operated with the longest anoxic periods (3 and 4 h) showed the lowest levels of Nitrobacter, compared to the other reactors. Nitrosomonas sp. strain Nm107 was detected in all reactors, regardless of the reactor's performance. Close relatives of Nitrosomonas europaea, Nitrosomonas sp. strain ENI-11, and Nitrosospira multiformis were occasionally detected in all reactors. Biomass fractions of AOB and effluent ammonia concentrations were not significantly different among the reactors. NOB were more sensitive than AOB to long nonaeration periods, as nitrite accumulation and lower total NOB rRNA levels were observed for an ANA of 1 h:4 h. The reactor with the longest nonaeration time of 4 h performed partial nitrification, followed by denitrification via nitrite, whereas the other reactors removed nitrogen through traditional nitrification and denitrification via nitrate. Superior ammonia removal efficiencies were not associated with levels of specific AOB species or with higher AOB species diversity. PMID:16332848

  16. Effect of aeration rate on composting of penicillin mycelial dreg.

    PubMed

    Chen, Zhiqiang; Zhang, Shihua; Wen, Qinxue; Zheng, Jun

    2015-11-01

    Pilot scale experiments with forced aeration were conducted to estimate effects of aeration rates on the performance of composting penicillin mycelial dreg using sewage sludge as inoculation. Three aeration rates of 0.15, 0.50 and 0.90L/(min·kg) organic matter (OM) were examined. The principal physicochemical parameters were monitored during the 32day composting period. Results showed that the higher aeration rate of 0.90L/(min·kg) did not corresponded to a longer thermophilic duration and higher rates of OM degradation; but the lower aeration rate of 0.15L/(min·kg) did induce an accumulation of NH4(+)-N contents due to the inhibition of nitrification. On the other hand, aeration rate has little effect on degradation of penicillin. The results show that the longest phase of thermophilic temperatures≥55°C, the maximum NO3(-)-N content and seed germination, and the minimum C/N ratio were obtained with 0.50L/(min·kg) OM. Therefore, aeration rates of 0.50L/(min·kg) OM can be recommended for composting penicillin mycelial dreg. PMID:26574101

  17. Longitudinal micro-CT provides biomarkers of lung disease that can be used to assess the effect of therapy in preclinical mouse models, and reveal compensatory changes in lung volume

    PubMed Central

    Vande Velde, Greetje; Poelmans, Jennifer; De Langhe, Ellen; Hillen, Amy; Vanoirbeek, Jeroen; Himmelreich, Uwe; Lories, Rik J.

    2016-01-01

    ABSTRACT In vivo lung micro-computed tomography (micro-CT) is being increasingly embraced in pulmonary research because it provides longitudinal information on dynamic disease processes in a field in which ex vivo assessment of experimental disease models is still the gold standard. To optimize the quantitative monitoring of progression and therapy of lung diseases, we evaluated longitudinal changes in four different micro-CT-derived biomarkers [aerated lung volume, lung tissue (including lesions) volume, total lung volume and mean lung density], describing normal development, lung infections, inflammation, fibrosis and therapy. Free-breathing mice underwent micro-CT before and repeatedly after induction of lung disease (bleomycin-induced fibrosis, invasive pulmonary aspergillosis, pulmonary cryptococcosis) and therapy (imatinib). The four lung biomarkers were quantified. After the last time point, we performed pulmonary function tests and isolated the lungs for histology. None of the biomarkers remained stable during longitudinal follow-up of adult healthy mouse lungs, implying that biomarkers should be compared with age-matched controls upon intervention. Early inflammation and progressive fibrosis led to a substantial increase in total lung volume, which affects the interpretation of aerated lung volume, tissue volume and mean lung density measures. Upon treatment of fibrotic lung disease, the improvement in aerated lung volume and function was not accompanied by a normalization of the increased total lung volume. Significantly enlarged lungs were also present in models of rapidly and slowly progressing lung infections. The data suggest that total lung volume changes could partly reflect a compensatory mechanism that occurs during disease progression in mice. Our findings underscore the importance of quantifying total lung volume in addition to aerated lung or lesion volumes to accurately document growth and potential compensatory mechanisms in mouse models of

  18. POD study of aerated cavitation in a venturi nozzle

    NASA Astrophysics Data System (ADS)

    Tomov, P.; Danlos, A.; Khelladi, S.; Ravelet, F.; Sarraf, C.; Bakir, F.

    2015-12-01

    The fact of injecting bubbles into a cavitating flow influences typical cavitating behavior. Cavitation and aerated cavitation experiments has been carried out on a symmetrical venturi nozzle with convergent/divergent angles of 18° and 8°, respectively. A snapshot Proper Orthogonal Decomposition (POD) technique is used to identify different modes in terms of discharge flow velocity, pressure and injected quantity of air. The energy spectrum per given mode is also presented. The first four modes are outlined in the present paper for an aerated and non-aerated cavitating flows.

  19. Feasibility of automatic aeration for insect pest management for rice stored in East Texas

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Aeration using automatic controllers was compared with manually-activated aeration (manual aeration) in bins of farm-stored rice in Nome, TX, from 17 September 2002 through the end of the year. Manual aeration was defined as the farm owner activating the fans manually in mid-October, while automati...

  20. TEMPERATURE MONITORING AND AERATION STRATEGIES FOR STORED WHEAT IN THE CENTRAL PLAINS

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Two aeration strategies were compared to non-aeration in field tests of stored wheat in Kansas. An additional summer aeration cycle before the usual two autumn cycles produced better temperatures for insect control in the grain. Both aeration strategies yielded much better temperatures for insect co...

  1. Chronic lung injury risk estimates for urban areas having ozone patterns similar to those in the Northeast

    SciTech Connect

    Absil, M.; Narducci, P.; Whitfield, R. ); Richmond, H.M. . Office of Air Quality Planning and Standards)

    1991-01-01

    This paper describes the approach and result of an assessment of health risks associated with long-term exposure to ozone. The health endpoint of interest is the probability of formation of mild lesions in the centriacinar region of the lung among children living in New York City. The risk model incorporates an exposure model and a health model. The exposure model is preliminary results of the probabilistic NAAQS Exposure Model (P-NEM) for ozone, and the health model is the judgments of active researchers about the likelihood of formation of ozone-induced lesions in the human lung. Children and New York City were chosen as the population and city of interest because it is believed that children are more sensitive to ozone than any other group of people, and New York City is more representative of other urban areas than Los Angeles, the other city of which P-NEM exposure results are available. Risk results are presented for ten exposure distributions generated by P-NEM, two air quality scenarios ( as-is'' and attainment''), and two exposure periods (1 and 10 ozone seasons). The results vary across experts, are not very sensitive to variations in P-NEM exposure distributions, are lower for attainment conditions than as-is conditions, and are lower for 1 season of exposure than 10 seasons. Although these results are specific to children living in areas having exposure patterns similar to those found in the Northeast, they are fairly representative of results for outdoor workers in the Northeast and Southern California and for children in Southern California. The reason for this is that many experts believe that children and outdoor workers respond in a similar fashion to the given exposure patterns, or that exposure patterns in the Northeast and Southern California are similar. Some experts held both of these beliefs. These results should help policymakers evaluate alternative national ambient air quality standards for ozone. 4 refs., 9 figs., 3 tabs.

  2. Chronic lung injury risk estimates for urban areas having ozone patterns similar to those in the Northeast

    SciTech Connect

    Absil, M.; Narducci, P.; Whitfield, R.; Richmond, H.M.

    1991-12-31

    This paper describes the approach and result of an assessment of health risks associated with long-term exposure to ozone. The health endpoint of interest is the probability of formation of mild lesions in the centriacinar region of the lung among children living in New York City. The risk model incorporates an exposure model and a health model. The exposure model is preliminary results of the probabilistic NAAQS Exposure Model (P-NEM) for ozone, and the health model is the judgments of active researchers about the likelihood of formation of ozone-induced lesions in the human lung. Children and New York City were chosen as the population and city of interest because it is believed that children are more sensitive to ozone than any other group of people, and New York City is more representative of other urban areas than Los Angeles, the other city of which P-NEM exposure results are available. Risk results are presented for ten exposure distributions generated by P-NEM, two air quality scenarios (``as-is`` and ``attainment``), and two exposure periods (1 and 10 ozone seasons). The results vary across experts, are not very sensitive to variations in P-NEM exposure distributions, are lower for attainment conditions than as-is conditions, and are lower for 1 season of exposure than 10 seasons. Although these results are specific to children living in areas having exposure patterns similar to those found in the Northeast, they are fairly representative of results for outdoor workers in the Northeast and Southern California and for children in Southern California. The reason for this is that many experts believe that children and outdoor workers respond in a similar fashion to the given exposure patterns, or that exposure patterns in the Northeast and Southern California are similar. Some experts held both of these beliefs. These results should help policymakers evaluate alternative national ambient air quality standards for ozone. 4 refs., 9 figs., 3 tabs.

  3. EVALUATION OF AERATION/CIRCULATION AS A LAKE RESTORATION TECHNIQUE

    EPA Science Inventory

    Artificial circulation and hypolimnetic aeration are management techniques for oxygenating eutrophic lakes subject to water quality problems, algal blooms, and fishkills. Artificial circulation is achieved by injecting diffused air into lower waters, by mechanial pumping of water...

  4. SURVEY AND EVALUATION OF FINE BUBBLE DOME DIFFUSER AERATION EQUIPMENT

    EPA Science Inventory

    This research project was initiated with the overall objective of better defining the oxygen transfer performance, operation and maintenance (O&M) requirements, and proper design approaches for fine bubble dome diffuser aeration systems used in activated sludge wastewater treatme...

  5. INVESTIGATION INTO BIOFOULING PHENOMENA IN FINE PORE AERATION DEVICES

    EPA Science Inventory

    Microbiologically-based procedures were used to describe biofouling phenomena on fine pore aeration devices and to determine whether biofilm characteristics could be related to diffuser process performance parameters. ine pore diffusers were obtained from five municipal wastewate...

  6. INVESTIGATIONS INTO BIOFOULING PHENOMENA IN FINE PORE AERATION DEVICES

    EPA Science Inventory

    Microbiologically-based procedures were used to describe biofouling phenomena on fine pore aeration devices and to determine whether biofilm characteristics could be related to diffuser process performance parameters. Fine pore diffusers were obtained from five municipal wastewa...

  7. TVA`s auto-venting turbines increase downstream aeration

    SciTech Connect

    March, P.

    1996-10-01

    Two auto-venting turbines installed at Norris Hydro Plant to increase dissolved-oxygen levels are briefly described. The turbines introduce aeration through the thrust relief openings, the deflector, the trailing edge of each blade, and the periphery of the draft tube. Downstream dissolved-oxygen levels have been increased by up to 5.5 milligrams per liter. Efficiency losses range from 0 to 4 percent, depending on operating conditions and aeration method.

  8. Emissions of hazardous air pollutants from aeration tanks

    SciTech Connect

    Zhu, H.; Keener, T.C.; Bishop, P.L.; Orton, T.L.; Wang, M.; Siddiqui, K.F.

    1998-12-31

    Regulated under the 1990 Clean Air Act Amendments (CAAA), Publicly Owned Treatment Works (POT Ws) need to inventory and control their hazardous air pollutant (HAP) emissions, primarily from the aeration tanks. The spatial characteristics of hazardous air pollutant (HAP) emissions, primarily from the aeration tanks. The spatial characteristics of hazardous air pollutants in the form of volatile organic compounds (VOCs) from the aeration units of POTWs have been investigated by systematic monitoring and mathematical modeling. Using a verified off-gas sampling system and CC-MS analytical method, a large wastewater treatment plant has been tested to understand the air emissions from its aeration basins. Variations of VOC emissions along the length of the aeration units have been tested and modeled. Most VOCs have decreasing concentration profiles. A simple PFR model has been developed to obtain the spatial information of the VOC fate. This model can be easily used to validate model parameters and accurately simulate the process especially in the case where the aeration tanks are operated with varied airflow rates along the tank length. Using this simple model, air emissions can be accurately estimated and the simulation results are useful to support an emissions control analysis. This study also reveals that simple multiplication of measured off-gas concentration and total airflow over-estimates the overall emissions.

  9. Pleuropulmonary blastoma in the area of a previously diagnosed congenital lung cyst: report of two cases.

    PubMed

    Hasiotou, M; Polyviou, P; Strantzia, C M; Pourtsidis, A; Stinios, I

    2004-05-01

    Pleuropulmonary blastoma (PPB) is a rare primary malignant pulmonary tumor in pediatric patients. We report the development of PPB in the area of a previous pulmonary cyst in two children, one boy and one girl 5 and 12 years old, respectively. We present the clinical and radiological findings. A short review of the literature is included. PMID:15239424

  10. A new step aeration approach towards the improvement of nitrogen removal in a full scale Carrousel oxidation ditch.

    PubMed

    Jin, Pengkang; Wang, Xianbao; Wang, Xiaochang; Ngo, Huu Hao; Jin, Xin

    2015-12-01

    Two aeration modes, step aeration and point aeration, were used in a full-scale Carrousel oxidation ditch with microporous aeration. The nitrogen removal performance and mechanism were analyzed. With the same total aeration input, both aeration modes demonstrated good nitrification outcomes with the average efficiency in removing NH4(+)-N of more than 98%. However, the average removal efficiencies for total nitrogen were 89.3% and 77.6% under step aeration and point aeration, respectively. The results indicated that an extended aerobic zone followed the aeration zones could affect the proportion of anoxic and oxic zones. The step aeration with larger anoxic zones indicated better TN removal efficiency. More importantly, step aeration provided the suitable environment for both nitrifiers and denitrifiers. The diversity and relative abundance of denitrifying bacteria under the step aeration (1.55%) was higher than that under the point aeration (1.12%), which resulted in an overall higher TN removal efficiency. PMID:26363498

  11. Characterization of Odorant Compounds from Mechanical Aerated Pile Composting and Static Aerated Pile Composting.

    PubMed

    Kumari, Priyanka; Lee, Joonhee; Choi, Hong-Lim

    2016-04-01

    We studied airborne contaminants (airborne particulates and odorous compounds) emitted from compost facilities in South Korea. There are primarily two different types of composting systems operating in Korean farms, namely mechanical aerated pile composting (MAPC) and aerated static pile composting (SAPC). In this study, we analyzed various particulate matters (PM10, PM7, PM2.5, PM1, and total suspended particles), volatile organic compounds and ammonia, and correlated these airborne contaminants with microclimatic parameters, i.e., temperature and relative humidity. Most of the analyzed airborne particulates (PM7, PM2.5, and PM1) were detected in high concentration at SAPC facilities compered to MAPC; however these differences were statistically non-significant. Similarly, most of the odorants did not vary significantly between MAPC and SAPC facilities, except for dimethyl sulfide (DMS) and skatole. DMS concentrations were significantly higher in MAPC facilities, whereas skatole concentrations were significantly higher in SAPC facilities. The microclimate variables also did not vary significantly between MAPC and SAPC facilities, and did not correlate significantly with most of the airborne particles and odorous compounds, suggesting that microclimate variables did not influence their emission from compost facilities. These findings provide insight into the airborne contaminants that are emitted from compost facilities and the two different types of composting agitation systems. PMID:26949962

  12. Characterization of Odorant Compounds from Mechanical Aerated Pile Composting and Static Aerated Pile Composting

    PubMed Central

    Kumari, Priyanka; Lee, Joonhee; Choi, Hong-Lim

    2016-01-01

    We studied airborne contaminants (airborne particulates and odorous compounds) emitted from compost facilities in South Korea. There are primarily two different types of composting systems operating in Korean farms, namely mechanical aerated pile composting (MAPC) and aerated static pile composting (SAPC). In this study, we analyzed various particulate matters (PM10, PM7, PM2.5, PM1, and total suspended particles), volatile organic compounds and ammonia, and correlated these airborne contaminants with microclimatic parameters, i.e., temperature and relative humidity. Most of the analyzed airborne particulates (PM7, PM2.5, and PM1) were detected in high concentration at SAPC facilities compered to MAPC; however these differences were statistically non-significant. Similarly, most of the odorants did not vary significantly between MAPC and SAPC facilities, except for dimethyl sulfide (DMS) and skatole. DMS concentrations were significantly higher in MAPC facilities, whereas skatole concentrations were significantly higher in SAPC facilities. The microclimate variables also did not vary significantly between MAPC and SAPC facilities, and did not correlate significantly with most of the airborne particles and odorous compounds, suggesting that microclimate variables did not influence their emission from compost facilities. These findings provide insight into the airborne contaminants that are emitted from compost facilities and the two different types of composting agitation systems. PMID:26949962

  13. Unilateral pleural effusion in an animal model: evaluation of lung function with EBCT

    NASA Astrophysics Data System (ADS)

    Recheis, Wolfgang A.; Pallwein, Leo; Soegner, Peter; Faschingbauer, Ralph; Schmidbauer, Georg; Kleinsasser, Axel; Loeckinger, Alexander; Hoermann, Christoph; zur Nedden, Dieter

    2003-05-01

    The purpsoe was to evaluate the influence of a right-sided pleural effusion on the lung aeration dynamics in the respiratory cycle during pressure controlled ventilation. Pleural effusion was simulated by infusion of 3% gelatin into the pleural cavity in steps of 300ml totaling 1200ml in four anesthetized pigs. After each step, volume scans and respirator gated 50ms scans at a constant table position (carina niveau) were taken. The dynamic changes of the previously defined air-tissue ratios (in steps of 100HU) were evaluated in three separate regions of left and right lung: a ventral, an intermediate and a dorsal area. The affected side revealed dramatic alveolar collapse. There was a shift of the lung density to higher air-tissue ratios (+200HU) but showing the same air-tissue ratio dynamics. A slight lateral shift of 32mm (+/-14mm) the mediastinum was measured. The unaffected side showed no increase in the air-tissue ratios caused by hyperinflation but an increase of density due to mediastinal shift. Air-tissue ratio dynamics remained unchanged on the unaffected side compared to baseline measurements. We visualized the ventilation mismatch caused by pleural effusion. The contra-lateral lung is not affected by unilateral pleural effusion. Pressure controlled ventilation prevents hyper-inflation of non-dependent lung areas.

  14. Nanoquartz in Late Permian C1 coal and the high incidence of female lung cancer in the Pearl River Origin area: a retrospective cohort study

    PubMed Central

    Tian, Linwei; Dai, Shifeng; Wang, Jianfang; Huang, Yunchao; Ho, Suzanne C; Zhou, Yiping; Lucas, Donald; Koshland, Catherine P

    2008-01-01

    Background The Pearl River Origin area, Qujing District of Yunnan Province, has one of the highest female lung cancer mortality rates in China. Smoking was excluded as a cause of the lung cancer excess because almost all women were non-smokers. Crystalline silica embedded in the soot emissions from coal combustion was found to be associated with the lung cancer risk in a geographical correlation study. Lung cancer rates tend to be higher in places where the Late Permian C1 coal is produced. Therefore, we have hypothesized the two processes: C1 coal combustion --> nanoquartz in ambient air --> lung cancer excess in non-smoking women. Methods/Design We propose to conduct a retrospective cohort study to test the hypothesis above. We will search historical records and compile an inventory of the coal mines in operation during 1930–2009. To estimate the study subjects' retrospective exposure, we will reconstruct the historical exposure scenario by burning the coal samples, collected from operating or deserted coal mines by coal geologists, in a traditional firepit of an old house. Indoor air particulate samples will be collected for nanoquartz and polycyclic aromatic hydrocarbons (PAHs) analyses. Bulk quartz content will be quantified by X-ray diffraction analysis. Size distribution of quartz will be examined by electron microscopes and by centrifugation techniques. Lifetime cumulative exposure to nanoquartz will be estimated for each subject. Using the epidemiology data, we will examine whether the use of C1 coal and the cumulative exposure to nanoquartz are associated with an elevated risk of lung cancer. Discussion The high incidence rate of lung cancer in Xuan Wei, one of the counties in the current study area, was once attributed to high indoor air concentrations of PAHs. The research results have been cited for qualitative and quantitative cancer risk assessment of PAHs by the World Health Organization and other agencies. If nanoquartz is found to be the main

  15. Seasonal variations and aeration effects on water quality improvements and physiological responses of Nymphaea tetragona Georgi.

    PubMed

    Lu, Xiao-Ming; Lu, Peng-Zhen; Huang, Min-Sheng; Dai, Ling-Peng

    2013-01-01

    Seasonal variations and aeration effects on water quality improvements and the physiological responses of Nymphaea tetragona Georgi were investigated with mesocosm experiments. Plants were hydroponically cultivated in six purifying tanks (aerated, non-aerated) and the characteristics of the plants were measured. Water quality improvements in purifying tanks were evaluated by comparing to the control tanks. The results showed that continuous aeration affected the plant morphology and physiology. The lengths of the roots, petioles and leaf limbs in aeration conditions were shorter than in non-aeration conditions. Chlorophyll and soluble protein contents of the leaf limbs in aerated tanks decreased, while peroxidase and catalase activities of roots tissues increased. In spring and summer, effects of aeration on the plants were less than in autumn. Total nitrogen (TN) and ammonia nitrogen (NH4(+)-N) in aerated tanks were lower than in non-aerated tanks, while total phosphorus (TP) and dissolved phosphorus (DP) increased in spring and summer. In autumn, effects of aeration on the plants became more significant. TN, NH4(+)-N, TP and DP became higher in aerated tanks than in non-aerated tanks in autumn. This work provided evidences for regulating aeration techniques based on seasonal variations of the plant physiology in restoring polluted stagnant water. PMID:23819294

  16. Pure and aerated water entry of a flat plate

    NASA Astrophysics Data System (ADS)

    Ma, Z. H.; Causon, D. M.; Qian, L.; Mingham, C. G.; Mai, T.; Greaves, D.; Raby, A.

    2016-01-01

    This paper presents an experimental and numerical investigation of the entry of a rigid square flat plate into pure and aerated water. Attention is focused on the measurement and calculation of the slamming loads on the plate. The experimental study was carried out in the ocean basin at Plymouth University's COAST laboratory. The present numerical approach extends a two-dimensional hydro-code to compute three-dimensional hydrodynamic impact problems. The impact loads on the structure computed by the numerical model compare well with laboratory measurements. It is revealed that the impact loading consists of distinctive features including (1) shock loading with a high pressure peak, (2) fluid expansion loading associated with very low sub-atmospheric pressure close to the saturated vapour pressure, and (3) less severe secondary reloading with super-atmospheric pressure. It is also disclosed that aeration introduced into water can effectively reduce local pressures and total forces on the flat plate. The peak impact loading on the plate can be reduced by half or even more with 1.6% aeration in water. At the same time, the lifespan of shock loading is prolonged by aeration, and the variation of impulse is less sensitive to the change of aeration than the peak loading.

  17. Numerical simulation of landfill aeration using computational fluid dynamics.

    PubMed

    Fytanidis, Dimitrios K; Voudrias, Evangelos A

    2014-04-01

    The present study is an application of Computational Fluid Dynamics (CFD) to the numerical simulation of landfill aeration systems. Specifically, the CFD algorithms provided by the commercial solver ANSYS Fluent 14.0, combined with an in-house source code developed to modify the main solver, were used. The unsaturated multiphase flow of air and liquid phases and the biochemical processes for aerobic biodegradation of the organic fraction of municipal solid waste were simulated taking into consideration their temporal and spatial evolution, as well as complex effects, such as oxygen mass transfer across phases, unsaturated flow effects (capillary suction and unsaturated hydraulic conductivity), temperature variations due to biochemical processes and environmental correction factors for the applied kinetics (Monod and 1st order kinetics). The developed model results were compared with literature experimental data. Also, pilot scale simulations and sensitivity analysis were implemented. Moreover, simulation results of a hypothetical single aeration well were shown, while its zone of influence was estimated using both the pressure and oxygen distribution. Finally, a case study was simulated for a hypothetical landfill aeration system. Both a static (steadily positive or negative relative pressure with time) and a hybrid (following a square wave pattern of positive and negative values of relative pressure with time) scenarios for the aeration wells were examined. The results showed that the present model is capable of simulating landfill aeration and the obtained results were in good agreement with corresponding previous experimental and numerical investigations. PMID:24525420

  18. Recirculation or artificial aeration in vertical flow constructed wetlands: a comparative study for treating high load wastewater.

    PubMed

    Foladori, Paola; Ruaben, Jenny; Ortigara, Angela R C

    2013-12-01

    Vertical subsurface-flow constructed wetlands at pilot-scale have been applied to treat high hydraulic and organic loads by implementing the following configurations: (1) intermittent recirculation of the treated wastewater from the bottom to the top of the bed, (2) intermittent artificial aeration supplied at the bottom of the bed and (3) the combination of both. These configurations were operated with a saturated bottom layer for a 6h-treatment phase, followed by a free drainage phase prior to a new feeding. COD removal efficiency was 85-90% in all the configurations and removed loads were 54-70 gCOD m(-2)d(-1). The aerated and recirculated wetland resulted in a higher total nitrogen removal (8.6 gN m(-2)d(-1)) due to simultaneous nitrification/denitrification, even in the presence of intermittent aeration (6.8 Nm(3)m(-2)d(-1)). The extra investment needed for implementing aeration/recirculation would be compensated for by a reduction of the surface area per population equivalent, which decreased to 1.5m(2)/PE. PMID:24128403

  19. Evaluation of design factors for a cascade aerator to enhance the efficiency of an oxidation pond for ferruginous mine drainage.

    PubMed

    Oh, Chamteut; Ji, Sangwoo; Cheong, Youngwook; Yim, Giljae; Hong, Ji-Hye

    2016-10-01

    This research focused on the optimum design of a cascade aerator to enhance the efficiency of an oxidation pond in a passive treatment system for remediating ferruginous mine drainage. For this purpose, various aeration experiments with aerators of different drop heights (0-4 m) and formations (types A and B) were executed on mine drainage. Type A simply drops the mine drainage into the oxidation pond while type B sprays the mine drainage and retains it for 8 min in each step. The efficiency enhancement of the oxidation pond was strongly dependent on the increase in pH and DO of the mine drainage discharged into the pond. The water quality improved with the increase in drop height but especially showed better effect with type B. The reasons for this result were attributed to the increase of contact surface and retention time of the mine drainage. The cascade aerator, therefore, should be designed to be as high as possible with the assistance of spraying form and retention time of the mine drainage to maximize the efficiency of the oxidation pond. These effects could be evaluated by calculating required areas of the oxidation pond for 95% of Fe(2+) oxidation. PMID:26936197

  20. Root aeration improves growth and nitrogen accumulation in rice seedlings under low nitrogen

    PubMed Central

    Zhu, Jingwen; Liang, Jing; Xu, Zhihui; Fan, Xiaorong; Zhou, Quansuo; Shen, Qirong; Xu, Guohua

    2015-01-01

    In wetland soils, changes in oxygen (O2) level in the rhizosphere are believed to influence the behaviour of nutrients and their usage by plants. However, the effect of aeration on nitrogen (N) acquisition under different N supply conditions remains largely unknown. In this study, the rice cultivars Yangdao 6 (YD6, with higher root aerenchyma abundance) and Nongken 57 (NK57, with lower root aerenchyma abundance) were used to evaluate the effects of aeration on rice growth and N accumulation. Our results showed that the number of adventitious roots and the root surface area increased significantly, and ethylene production and aerenchyma formation decreased in both cultivars after external aeration (EA). Five N treatments, including no N (−N), 0.125 mM NH4NO3 (LN), 1.25 mM Ca(NO3)2 (NO3-N), 1.25 mM (NH4)2SO4 (NH4-N) and 1.25 mM NH4NO3 (N/N), were applied to YD6 and NK57 for 2 days under internal aeration or EA conditions. External aeration increased the root biomass in both cultivars and the shoot biomass in NK57 by 18–50 %. The total N concentrations in roots of YD6 grown under −N and LN and of NK57 grown under NO3-N were increased by EA. Expression of OsPAD4, one of four putative genes regulating aerenchyma formation, showed a similar pattern alongside changes in the ethylene level in the EA-treated rice irrespective of the N treatments. Furthermore, expression of the high-affinity nitrate transporter gene OsNRT2.1 was increased by EA under −N, LN and NO3-N conditions. Our data provide evidence of an interaction between O2 and the supply of N in ethylene production, aerenchyma formation and N nutrition through modification of the expression of OsPAD4 and OsNRT2.1. PMID:26578743

  1. Root aeration improves growth and nitrogen accumulation in rice seedlings under low nitrogen.

    PubMed

    Zhu, Jingwen; Liang, Jing; Xu, Zhihui; Fan, Xiaorong; Zhou, Quansuo; Shen, Qirong; Xu, Guohua

    2015-01-01

    In wetland soils, changes in oxygen (O2) level in the rhizosphere are believed to influence the behaviour of nutrients and their usage by plants. However, the effect of aeration on nitrogen (N) acquisition under different N supply conditions remains largely unknown. In this study, the rice cultivars Yangdao 6 (YD6, with higher root aerenchyma abundance) and Nongken 57 (NK57, with lower root aerenchyma abundance) were used to evaluate the effects of aeration on rice growth and N accumulation. Our results showed that the number of adventitious roots and the root surface area increased significantly, and ethylene production and aerenchyma formation decreased in both cultivars after external aeration (EA). Five N treatments, including no N (-N), 0.125 mM NH4NO3 (LN), 1.25 mM Ca(NO3)2 (NO3-N), 1.25 mM (NH4)2SO4 (NH4-N) and 1.25 mM NH4NO3 (N/N), were applied to YD6 and NK57 for 2 days under internal aeration or EA conditions. External aeration increased the root biomass in both cultivars and the shoot biomass in NK57 by 18-50 %. The total N concentrations in roots of YD6 grown under -N and LN and of NK57 grown under NO3-N were increased by EA. Expression of OsPAD4, one of four putative genes regulating aerenchyma formation, showed a similar pattern alongside changes in the ethylene level in the EA-treated rice irrespective of the N treatments. Furthermore, expression of the high-affinity nitrate transporter gene OsNRT2.1 was increased by EA under -N, LN and NO3-N conditions. Our data provide evidence of an interaction between O2 and the supply of N in ethylene production, aerenchyma formation and N nutrition through modification of the expression of OsPAD4 and OsNRT2.1. PMID:26578743

  2. Ionization and chemiluminescence during the progressive aeration of methane flames

    SciTech Connect

    Weinberg, Felix; Carleton, Fred

    2009-12-15

    Saturation currents and chemiluminescence, especially at the CH{sup *} and C{sub 2}{sup *} wavelengths, are measured for a range of small, laminar methane flames during progressive addition of air, with the principal objective of distinguishing between pure diffusion flames, premixed flames of compositions falling between the upper and lower flammability limits, and the broad range of aerated flames lying in between these regimes. Flame areas defined by the loci of maximum luminosity and by schlieren contours were recorded, so that saturation current densities, CH{sup *} and C{sub 2}{sup *} emission per unit flame area, as well as burning velocities could be deduced. For admixtures of less than 70 vol.%, air appears to act, surprisingly, as an inert diluent as regards saturation currents, so that saturation currents are essentially proportional to fuel flow alone. Much the same applies to chemiluminescence. However, schlieren contours, which were recorded both to provide a basis for burning velocity measurements and to explore density changes in the reactants, indicated the presence of a burner - stabilised propagating reaction zone ahead of the luminous flame surface starting at around 50 vol.% and possibly even at lower air admixtures. This evidence of a steep change in refractive index is indicative of a premixed reaction zone involving the added oxygen, which however generates no chemi-ionization and emits no light. Even photographing the flame by radiation emitted at the CH{sup *} and C{sub 2}{sup *} wavelengths shows no sign of its existence. Its burning velocity is about 10 cm/s, when stabilized by the surrounding diffusion flame. The most plausible rationale for these observations is the formation of syngas by the partial oxidation of methane. The subsequent burning of CO and H{sub 2} is known to occur without chemi-ionization or appreciable light emission. (author)

  3. Control of a mechanical aeration process via topological sensitivity analysis

    NASA Astrophysics Data System (ADS)

    Abdelwahed, M.; Hassine, M.; Masmoudi, M.

    2009-06-01

    The topological sensitivity analysis method gives the variation of a criterion with respect to the creation of a small hole in the domain. In this paper, we use this method to control the mechanical aeration process in eutrophic lakes. A simplified model based on incompressible Navier-Stokes equations is used, only considering the liquid phase, which is the dominant one. The injected air is taken into account through local boundary conditions for the velocity, on the injector holes. A 3D numerical simulation of the aeration effects is proposed using a mixed finite element method. In order to generate the best motion in the fluid for aeration purposes, the optimization of the injector location is considered. The main idea is to carry out topological sensitivity analysis with respect to the insertion of an injector. Finally, a topological optimization algorithm is proposed and some numerical results, showing the efficiency of our approach, are presented.

  4. Activated sludge process performance using a multistage tower aeration tank

    SciTech Connect

    Shimizu, Tatsuo; Kudo, Kenzo; Nasu, Yoshikazu )

    1993-07-01

    This study's objective was to clarify both experimentally and theoretically whether a vertical multistage tower aeration tank system is advantageous as compared with a completely mixed system, particularly with respect to purification efficiency, sludge settleability, and excess sludge production. In comparing the two systems: (1) purification efficiency in the multistage tower aeration system with partial fluid mixing with a large Peclet number was higher than in a corresponding completely mixed system for all applied organic loadings; (2) the multistage tower aeration system had some definite advantages with respect to sludge settleability and excess sludge production; and (3) the activated sludge system's higher performance with partial fluid mixing was shown quantitatively with the axial dispersion model in conjunction with growth kinetics which involved rapid uptake such as biosorption and subsequent oxidative biodegradation processes of organic substances.

  5. In situ groundwater aeration of polycyclic aromatic hydrocarbons

    SciTech Connect

    Symons, B.D.; Linkenheil, R.; Pritchard, D.; Shanke, C.A.; Seep, D.

    1995-12-31

    At a former wood treating site in Minnesota, the feasibility of in situ groundwater aeration was investigated in a laboratory treatability setting, to evaluate biodegradability and optimal operation conditions of the site aquifer. After concluding that an aeration system would increase the dissolved oxygen concentrations in the groundwater enough to sustain microbial life, a field demonstration system was designed and installed. The system was operated for 1 year, during which groundwater quality at upgradient and downgradient wells was monitored to evaluate the system`s effectiveness. The groundwater aeration system successfully reduced groundwater polycyclic aromatic hydrocarbon (PAH) concentrations, especially naphthalene. Naphthalene concentrations were reduced from 1,319 {micro}g/L to below the laboratory detection limit of 0.5 {micro}g/L. Cumulative concentrations of other PAH compounds were reduced from 98 {micro}g/L to 23 {micro}g/L during the 1-year test.

  6. Streamlined HUB baffles for aeration at Norris Dam

    SciTech Connect

    Harshbarger, E.D.

    1984-07-01

    Streamlined hub baffles were installed and tested as aeration devices on both hydro turbines at Norris Dam. The results indicated that the baffles can induce significant aeration with only a small effect on unit operation. At the most efficient wicket gate opening, the airflow/waterflow ratio was about 2.2 to 3.2% which produced dissolved oxygen increases in the tailrace on the order of 2.5 to 3.0 mg/L when the incoming dissolved oxygen concentration was 1 mg/L or less. The baffles with aeration reduced unit efficiency less than 0.5% and reduced unit capacity less than 1 MW. For the final design, the baffles were bolted on and could be installed or removed in one eight-hour period or less.

  7. Aspects concerning the quality of aeration for environmental friendly turbines

    NASA Astrophysics Data System (ADS)

    Bunea, F.; Houde, S.; Ciocan, G. D.; Oprina, G.; Baran, G.; Pincovschi, I.

    2010-08-01

    The hydro renewable energy provides a reliable power source; it does not pollute the air or land but affects the aquatic habitat due to low dissolved oxygen (DO) level in the water discharged from turbines. Hydro-turbines intake generally withdraws water from the bottom layer of the reservoirs with low DO level. In the different methods used for improving DO downstream the hydropower plants the volume of air is considered to be the main parameter of the injection. The energetic consumption is affected, in terms of loss of turbine efficiency due to air injection. The authors propose a study to show the importance of the quality of air injection, meaning bubble size, pressure loss on the aeration device etc. Different types of fine bubble aeration systems have been tested and compared. The capacity to predict the aeration by numerical simulation is analysed.

  8. Retrofitting activated sludge systems to intermittent aeration for nitrogen removal.

    PubMed

    Hanhan, O; Artan, N; Orhon, D

    2002-01-01

    The paper provides the basis and the conceptual approach of applying process kinetics and modelling to the design of alternating activated sludge systems for retrofitting existing activated sludge plants to intermittent aeration for nitrogen removal. It shows the significant role of the two specific parameters, namely, the aerated fraction and the cycle time ratio on process performance through model simulations and proposes a way to incorporate them into a design procedure using process stoichiometry and mass balance. It illustrates the effect of these parameters, together with the sludge age, in establishing the balance between the denitrification potential and the available nitrogen created in the anoxic/aerobic sequences of system operation. PMID:12420968

  9. A simple empirical model of aeration at navigation dams

    SciTech Connect

    Railsback, S.F.

    1990-01-01

    In a study of aeration at 28 dams in the upper Ohio River basin, a least-squares linear regression model was developed to predict the dissolved oxygen deficit below the dam as a linear function of the deficit above the dam. A linear statistical model was chosen because theory-based models are not readily applicable to navigation dams and because previous empirical models do not simulate the supersaturation that field data showed. The statistical model simulates supersaturation, is an adequate predictor of aeration at almost all of the dams, and allows easy analysis of uncertainties. 8 refs., 6 figs.

  10. In-tank aeration, a necessary compliment of loaded systems in an airlift recirculating aquaculture system

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Water treatment components in recirculating aquaculture systems in generally address solids removal, nitrification, circulation, aeration, and degasification. Airlift pumps in a recirculating aquaculture system can address water circulation, aeration, and degasification. Recent data indicates oxygen...

  11. EVALUATING THE QUALITY OF WATER TREATED BY REDWOOD SLAT TOWER AERATORS

    EPA Science Inventory

    Over a two year period, the U.S. Environmental Protection Agency, Drinking Water Research Division (EPA-DWRD), and two New England water utilities evaluated the water quality from redwood slat tower aerators. Samples of aerator influent and aerator effluent were analyzed for seve...

  12. Dissolved Oxygen management in catfish ponds using electric paddlewheel aerators: new approaches with old technology

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The electric paddlewheel aerator has been the main aerator used in the U.S. catfish industry for the post forty years. While it has its limitations, it is perhaps the most efficient shallow-water aerator yet to be developed. Its shortcomings result not so much from poor design, as from poor usage. U...

  13. Development and evaluation of a new aerator for the catfish industry

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Traditional paddle-wheel aerators have been used for supplemental and emergency aeration in the aquaculture industry for over 30 years but distribute a high volume of water which dilutes the aeration effort over the entire pond volume. Thus, a great deal of equipment and a large amount of power is r...

  14. Directional Flow of Summer Aeration to Manage Insect Pests in Stored Wheat

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Field trials were conducted in metal wheat storage bins to determine whether pressure aeration, pushing ambient air from the bottom, or suction aeration, pulling air down from the top, would be more efficient at cooling the wheat mass and thereby limiting insect population growth. Aeration was accom...

  15. Intermittent aeration to improve wastewater treatment efficiency in pilot-scale constructed wetland.

    PubMed

    Uggetti, Enrica; Hughes-Riley, Theodore; Morris, Robert H; Newton, Michael I; Trabi, Christophe L; Hawes, Patrick; Puigagut, Jaume; García, Joan

    2016-07-15

    Forced aeration of horizontal subsurface flow constructed wetlands (HSSF CWs) is nowadays a recognized method to improve treatment efficiency, mainly in terms of ammonium removal. While numerous investigations have been reported testing constant aeration, scarce information can be found about the efficiency of intermittent aeration. This study aims at comparing continuous and intermittent aeration, establishing if there is an optimal regime that will increase treatment efficiency of HSSF CWs whilst minimizing the energy requirement. Full and intermittent aeration were tested in a pilot plant of three HSSF CWs (2.64m(2) each) fed with primary treated wastewater. One unit was fully aerated; one intermittently aerated (i.e. by setting a limit of 0.5mg/L dissolved oxygen within the bed) with the remaining unit not aerated as a control. Results indicated that intermittent aeration was the most successful operating method. Indeed, the coexistence of aerobic and anoxic conditions promoted by the intermittent aeration resulted in the highest COD (66%), ammonium (99%) and total nitrogen (79%) removals. On the other hand, continuous aeration promotes ammonium removal (99%), but resulted in nitrate concentrations in the effluent of up to 27mg/L. This study demonstrates the high potential of the intermittent aeration to increase wastewater treatment efficiency of CWs providing an extreme benefit in terms of the energy consumption. PMID:27062558

  16. A 79-Year-Old Man With Interstitial Lung Disease and Cryptic Area of High 18 Fluorodeoxyglucose Uptake in Left Upper Lobe.

    PubMed

    Rapicetta, Cristian; Lococo, Filippo; Carbonelli, Cristiano; Sverzellati, Nicola; Di Paolo, Maria Liberata; Cavazza, Alberto; Serra, Silvia; Ricchetti, Tommaso; Gasparini, Elisa; Cesario, Alfredo; Sgarbi, Giorgio; Brandi, Loris; Paci, Massimiliano

    2015-12-01

    Seven years after left hemicolectomy and radical lymph nodal dissection followed by adjuvant chemotherapy for colorectal cancer (histotype, adenocarcinoma; stage, pT3N2M0; grading, G2), a slight increase in carcinoembryonic antigen levels (6.2 ng/mL; range, 0-5 ng/mL) was detected in a 79-year-old man. He was a heavy smoker with history of an interstitial fibrotic lung disease with associated areas of emphysema. PMID:26621296

  17. Aerated Lagoons. Instructor's Guide. Biological Treatment Process Control.

    ERIC Educational Resources Information Center

    Andersen, Lorri

    This unit (which consists of a single lesson) describes the structural and operationally unique features of aerated lagoons. In addition, special troubleshooting and maintenance problems are discussed. The instructor's guide for the unit includes: (1) an overview of the lesson; (2) lesson plan; (3) lecture outline (keyed to a set of slides used…

  18. EFFECT OF AERATION OF SEDIMENT ON CADMIUM BINDING

    EPA Science Inventory

    Acid-volatile sulfide (AVS) has been shown to be the dominant phase reacting with metals in anoxic sediments. he AVS is sediment decreases upon resuspension due to storms and dredging, and in winter when the rate of aeration processes exceeds that of the formation of sulfide. e c...

  19. 6. AERATOR VIEWED UPSTREAM. DETAIL OF FLUSH VALVE AND VIEW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. AERATOR VIEWED UPSTREAM. DETAIL OF FLUSH VALVE AND VIEW INTO BOX FLUME. NOTE WRENCH TO OPEN VALVE AND REMAINS OF OLD SHOVEL USED FOR MAINTENANCE. TRASH SCREEN MESH IS SEEN AT BOTTOM LEFT. - Kalaupapa Water Supply System, Waikolu Valley to Kalaupapa Settlement, Island of Molokai, Kalaupapa, Kalawao County, HI

  20. Non-autoclaved aerated concrete with mineral additives

    NASA Astrophysics Data System (ADS)

    Il'ina, L. V.; Rakov, M. A.

    2016-01-01

    We investigated the effect of joint grinding of Portland cement clinker, silica and carbonate components and mineral additives to specific surface of 280 - 300 m2/kg on the properties (strength, average density and thermal conductivity) of non-autoclaved aerated concrete, and the porosity of the hardened cement paste produced from Portland cement clinker with mineral additives. The joint grinding of the Portland cement clinker with silica and carbonate components and mineral additives reduces the energy consumption of non-autoclaved aerated concrete production. The efficiency of mineral additives (diopside, wollastonite) is due to the closeness the composition, the type of chemical bonds, physical and chemical characteristics (specific enthalpy of formation, specific entropy) to anhydrous clinker minerals and their hydration products. Considering the influence of these additions on hydration of clinker minerals and formation of hardened cement paste structure, dispersed wollastonite and diopside should be used as mineral additives. The hardness and, consequently, the elastic modulus of diopside are higher than that of hardened cement paste. As a result, there is a redistribution of stresses in the hardened cement paste interporous partitions and hardening, both the partitions and aerated concrete on the whole. The mineral additives introduction allowed to obtain the non-autoclaved aerated concrete with average density 580 kg/m3, compressive strength of 3.3 MPa and thermal conductivity of 0.131 W/(m.°C).

  1. SAFETY ASPECTS OF OXYGEN AERATION ACTIVATED SLUDGE SYSTEMS

    EPA Science Inventory

    This project was carried out to assess the impact of the use of oxygen and oxygen-enriched air for aeration of activated sludge systems on the safety of municipal waste-water treatment plants and their personnel. The tasks included (1) determination of oxygen combustion hazards f...

  2. No-till bioenergy cropping systems effect on soil aeration

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Bioenergy cropping systems have been proposed as a way to enhance United States energy security. However, research on soil quality, such as the effects of maize stover harvesting on soil aeration and the relationships to soil structure and water, associated with bioenergy cropping systems has been l...

  3. 4. AERATOR AT 525, CONSTRUCTED 19371938, VIEW FROM UPSTREAM (TRASH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. AERATOR AT 525, CONSTRUCTED 1937-1938, VIEW FROM UPSTREAM (TRASH SCREEN REMOVED FOR CLARITY), WATER FROM INTAKE FLOWS THROUGH FLUME, THEN DAMS, AND SPILLS OVER STEPS TO MIX WITH OXYGEN, THUS REDUCING ACIDITY LEVELS. ACID INDUCES FASTER CORROSION OF PIPES AND SPOILS TASTE. - Kalaupapa Water Supply System, Waikolu Valley to Kalaupapa Settlement, Island of Molokai, Kalaupapa, Kalawao County, HI

  4. 5. AERATOR VIEW FROM DOWNSTREAM. FLUSH VALVE AT RIGHT OPENS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. AERATOR VIEW FROM DOWNSTREAM. FLUSH VALVE AT RIGHT OPENS TO CLEAR THE SYSTEM ABOVE THE SILT AND DEBRIS AND TO STOP THE FLOW OF WATER INTO THE SYSTEM DOWN LINE. BOX FLUME CONTINUES DOWN LINE TO SEDIMENTATION CHAMBER. - Kalaupapa Water Supply System, Waikolu Valley to Kalaupapa Settlement, Island of Molokai, Kalaupapa, Kalawao County, HI

  5. SUMMARY REPORT: FINE PORE (FINE BUBBLE) AERATION SYSTEMS

    EPA Science Inventory

    It is estimated that 50-90 percent of the power cost for wastewater treatment is for aeration. ine pore diffusion presents the opportunity to significantly reduce these costs due to its oxygen transfer efficiency. his report provides the latest information on pertormance potentia...

  6. SAFETY MANUAL FOR WASTEWATER TREATMENT WITH OXYGEN AERATION

    EPA Science Inventory

    This safety manual provides design, operating, and safety personnel of municipal wastewater treatment plants which use oxygen aeration of activated sludge systems with the knowledge to prevent hazards due to the interaction of the oxygen with combustibles and other hazardous mate...

  7. Particle-induced oxidative damage of indoor PM10 from coal burning homes in the lung cancer area of Xuan Wei, China

    NASA Astrophysics Data System (ADS)

    Shao, Longyi; Hu, Ying; Wang, Jing; Hou, Cong; Yang, Yuanyuan; Wu, Mingyuan

    2013-10-01

    The lung cancer mortality rate in the rural area of the Xuan Wei, Yunnan, is among the highest in China, especially in women. In this paper, the coal-burning indoor and corresponding outdoor PM10 samples were collected at the Hutou village, representing the case of high lung cancer rate, and the Xize village, representing the case of low lung cancer rate. Plasmid scission assay was used to investigate the bioreactivity of the PM10. The inductively coupled plasma-mass spectrometry (ICP-MS) was employed to investigate the trace element compositions of the PM10. The results showed that the oxidative damage caused by both indoor and outdoor PM10 at the Hutou village was obviously higher than that at the Xize village, with the indoor PM10 having higher oxidative damage than corresponding outdoors. Among all analyzed samples, the indoor night PM10 samples from the Hutou village have the highest oxidative capacity. The levels of total water-soluble elements had a higher level in the PM10 of the Hutou village than that of the Xize village. It is interesting that the levels of water-soluble As, Cd, Cs, Pb, Sb, Tl and Zn in PM10 had better positive correlation with DNA damage rates, implying that these elements in their water-soluble state should be one of the main factors responsible for the high oxidative capacity of PM10, thus possibly the higher lung cancer rates, at the Hutou village.

  8. The potential for aeration of MSW landfills to accelerate completion

    SciTech Connect

    Rich, Charlotte; Gronow, Jan; Voulvoulis, Nikolaos

    2008-07-01

    Landfilling is a popular waste disposal method, but, as it is practised currently, it is fundamentally unsustainable. The low short-term financial costs belie the potential long-term environmental costs, and traditional landfill sites require long-term management in order to mitigate any possible environmental damage. Old landfill sites might require aftercare for decades or even centuries, and in some cases remediation may be necessary. Biological stabilisation of a landfill is the key issue; completion criteria provide a yardstick by which the success of any new technology may be measured. In order for a site to achieve completion it must pose no risk to human health or the environment, meaning that attenuation of any emissions from the site must occur within the local environment without causing harm. Remediation of old landfill sites by aerating the waste has been undertaken in Germany, the United States, Italy and The Netherlands, with considerable success. At a pilot scale, aeration has also been used in newly emplaced waste to accelerate stabilisation. This paper reviews the use of aerobic landfill worldwide, and assesses the ways in which the use of aerobic landfill techniques can decrease the risks associated with current landfill practices, making landfill a more sustainable waste disposal option. It focuses on assessing ways to utilise aeration to enhance stabilisation. The results demonstrated that aeration of old landfill sites may be an efficient and cost-effective method of remediation and allow the date of completion to be brought forward by decades. Similarly, aeration of newly emplaced waste can be effective in enhancing degradation, assisting with completion and reducing environmental risks. However, further research is required to establish what procedure for adding air to a landfill would be most suitable for the UK and to investigate new risks that may arise, such as the possible emission of non-methane organic compounds.

  9. Regional Inequalities in Lung Cancer Mortality in Belgium at the Beginning of the 21st Century: The Contribution of Individual and Area-Level Socioeconomic Status and Industrial Exposure.

    PubMed

    Hagedoorn, Paulien; Vandenheede, Hadewijch; Willaert, Didier; Vanthomme, Katrien; Gadeyne, Sylvie

    2016-01-01

    Being a highly industrialized country with one of the highest male lung cancer mortality rates in Europe, Belgium is an interesting study area for lung cancer research. This study investigates geographical patterns in lung cancer mortality in Belgium. More specifically it probes into the contribution of individual as well as area-level characteristics to (sub-district patterns in) lung cancer mortality. Data from the 2001 census linked to register data from 2001-2011 are used, selecting all Belgian inhabitants aged 65+ at time of the census. Individual characteristics include education, housing status and home ownership. Urbanicity, unemployment rate, the percentage employed in mining and the percentage employed in other high-risk industries are included as sub-district characteristics. Regional variation in lung cancer mortality at sub-district level is estimated using directly age-standardized mortality rates. The association between lung cancer mortality and individual and area characteristics, and their impact on the variation of sub-district level is estimated using multilevel Poisson models. Significant sub-district variations in lung cancer mortality are observed. Individual characteristics explain a small share of this variation, while a large share is explained by sub-district characteristics. Individuals with a low socioeconomic status experience a higher lung cancer mortality risk. Among women, an association with lung cancer mortality is found for the sub-district characteristics urbanicity and unemployment rate, while for men lung cancer mortality was associated with the percentage employed in mining. Not just individual characteristics, but also area characteristics are thus important determinants of (regional differences in) lung cancer mortality. PMID:26760040

  10. Regional Inequalities in Lung Cancer Mortality in Belgium at the Beginning of the 21st Century: The Contribution of Individual and Area-Level Socioeconomic Status and Industrial Exposure

    PubMed Central

    Hagedoorn, Paulien; Vandenheede, Hadewijch; Willaert, Didier; Vanthomme, Katrien; Gadeyne, Sylvie

    2016-01-01

    Being a highly industrialized country with one of the highest male lung cancer mortality rates in Europe, Belgium is an interesting study area for lung cancer research. This study investigates geographical patterns in lung cancer mortality in Belgium. More specifically it probes into the contribution of individual as well as area-level characteristics to (sub-district patterns in) lung cancer mortality. Data from the 2001 census linked to register data from 2001–2011 are used, selecting all Belgian inhabitants aged 65+ at time of the census. Individual characteristics include education, housing status and home ownership. Urbanicity, unemployment rate, the percentage employed in mining and the percentage employed in other high-risk industries are included as sub-district characteristics. Regional variation in lung cancer mortality at sub-district level is estimated using directly age-standardized mortality rates. The association between lung cancer mortality and individual and area characteristics, and their impact on the variation of sub-district level is estimated using multilevel Poisson models. Significant sub-district variations in lung cancer mortality are observed. Individual characteristics explain a small share of this variation, while a large share is explained by sub-district characteristics. Individuals with a low socioeconomic status experience a higher lung cancer mortality risk. Among women, an association with lung cancer mortality is found for the sub-district characteristics urbanicity and unemployment rate, while for men lung cancer mortality was associated with the percentage employed in mining. Not just individual characteristics, but also area characteristics are thus important determinants of (regional differences in) lung cancer mortality. PMID:26760040

  11. Lung Transplant

    MedlinePlus

    ... the NHLBI on Twitter. What Is a Lung Transplant? A lung transplant is surgery to remove a person's diseased lung ... a healthy lung from a deceased donor. Lung transplants are used for people who are likely to ...

  12. Effect of spray aeration on organics and nitrogen removal in vertical subsurface flow constructed wetland.

    PubMed

    Ding, Yi; Wang, Wei; Song, Xin-Shan; Wang, Gang; Wang, Yu-Hui

    2014-12-01

    The objective of present study was to assess the simultaneous removal of organics and nitrogen by four lab-scale vertical subsurface flow constructed wetlands (V-SFCWs). The emergent plants employed were Canna indica. Five-month experiments showed that the planted and aerated system largely reduced the COD by 95%, NH4 by 88% and total inorganic nitrogen (TIN) by 83%. It outperformed the unplanted or simple aerated system and was much better than non-aerated system. The study provided a strong evidence to support widespread research and application of spray aeration as a low-cost and energy-efficient aeration technology in V-SFCWs. PMID:25259785

  13. Liquid and atmospheric ammonia concentrations from a dairy lagoon during an aeration experiment

    NASA Astrophysics Data System (ADS)

    Rumburg, Brian; Neger, Manjit; Mount, George H.; Yonge, David; Filipy, Jenny; Swain, John; Kincaid, Ron; Johnson, Kristen

    Ammonia emissions from agriculture are an environmental and human health concern, and there is increasing pressure to reduce emissions. Animal agriculture is the largest global source of ammonia emissions and on a per cow basis dairy operations are the largest emitters. The storage and disposal of the dairy waste is one area where emissions can be reduced, aerobic biological treatment of wastewater being a common and effective way of reducing ammonia emissions. An aeration experiment in a dairy lagoon with two commercial aerators was performed for 1 month. Liquid concentrations of ammonia, total nitrogen, nitrite and nitrate were monitored before, during and after the experiment and atmospheric ammonia was measured downwind of the lagoon using a short-path differential optical absorption spectroscopy (DOAS) instrument with 1 ppbv sensitivity. No changes in either liquid or atmospheric ammonia concentrations were detected throughout the experiment, and neither dissolved oxygen, nitrite nor nitrate could be detected in the lagoon at any time. The average ammonia concentration at 10 sampling sites in the lagoon at a depth of 0.15 m was 650 mg l -1 and at 0.90 m it was 700 mg l -1 NH 3-N. The average atmospheric ammonia concentration 50 m downwind was about 300 ppbv. The 0.90 m depth total nitrogen concentrations and total and volatile solids concentrations decreased during the experiment due to some mixing of the lagoon but the 0.15 m depth concentrations did not decrease indicating that the aerators were not strong enough to mix the sludge off the bottom into the whole water column.

  14. Redox potential driven aeration during very-high-gravity ethanol fermentation by using flocculating yeast

    PubMed Central

    Liu, Chen-Guang; Hao, Xue-Mi; Lin, Yen-Han; Bai, Feng-Wu

    2016-01-01

    Ethanol fermentation requires oxygen to maintain high biomass and cell viability, especially under very-high-gravity (VHG) condition. In this work, fermentation redox potential (ORP) was applied to drive the aeration process at low dissolved oxygen (DO) levels, which is infeasible to be regulated by a DO sensor. The performance and characteristics of flocculating yeast grown under 300 and 260 g glucose/L conditions were subjected to various aeration strategies including: no aeration; controlled aeration at −150, −100 and −50 mV levels; and constant aeration at 0.05 and 0.2 vvm. The results showed that anaerobic fermentation produced the least ethanol and had the highest residual glucose after 72 h of fermentation. Controlled aerations, depending on the real-time oxygen demand, led to higher cell viability than the no-aeration counterpart. Constant aeration triggered a quick biomass formation, and fast glucose utilization. However, over aeration at 0.2 vvm caused a reduction of final ethanol concentration. The controlled aeration driven by ORP under VHG conditions resulted in the best fermentation performance. Moreover, the controlled aeration could enhance yeast flocculating activity, promote an increase of flocs size, and accelerate yeast separation near the end of fermentation. PMID:27161047

  15. Redox potential driven aeration during very-high-gravity ethanol fermentation by using flocculating yeast.

    PubMed

    Liu, Chen-Guang; Hao, Xue-Mi; Lin, Yen-Han; Bai, Feng-Wu

    2016-01-01

    Ethanol fermentation requires oxygen to maintain high biomass and cell viability, especially under very-high-gravity (VHG) condition. In this work, fermentation redox potential (ORP) was applied to drive the aeration process at low dissolved oxygen (DO) levels, which is infeasible to be regulated by a DO sensor. The performance and characteristics of flocculating yeast grown under 300 and 260 g glucose/L conditions were subjected to various aeration strategies including: no aeration; controlled aeration at -150, -100 and -50 mV levels; and constant aeration at 0.05 and 0.2 vvm. The results showed that anaerobic fermentation produced the least ethanol and had the highest residual glucose after 72 h of fermentation. Controlled aerations, depending on the real-time oxygen demand, led to higher cell viability than the no-aeration counterpart. Constant aeration triggered a quick biomass formation, and fast glucose utilization. However, over aeration at 0.2 vvm caused a reduction of final ethanol concentration. The controlled aeration driven by ORP under VHG conditions resulted in the best fermentation performance. Moreover, the controlled aeration could enhance yeast flocculating activity, promote an increase of flocs size, and accelerate yeast separation near the end of fermentation. PMID:27161047

  16. The "baby lung" became an adult.

    PubMed

    Gattinoni, Luciano; Marini, John J; Pesenti, Antonio; Quintel, Michael; Mancebo, Jordi; Brochard, Laurent

    2016-05-01

    The baby lung was originally defined as the fraction of lung parenchyma that, in acute respiratory distress syndrome (ARDS), still maintains normal inflation. Its size obviously depends on ARDS severity and relates to the compliance of the respiratory system. CO2 clearance and blood oxygenation primarily occur within the baby lung. While the specific compliance suggests the intrinsic mechanical characteristics to be nearly normal, evidence from positron emission tomography suggests that at least a part of the well-aerated baby lung is inflamed. The baby lung is more a functional concept than an anatomical one; in fact, in the prone position, the baby lung "shifts" from the ventral lung regions toward the dorsal lung regions while usually increasing its size. This change is associated with better gas exchange, more homogeneously distributed trans-pulmonary forces, and a survival advantage. Positive end expiratory pressure also increases the baby lung size, both allowing better inflation of already open units and adding new pulmonary units. Viewed as surrogates of stress and strain, tidal volume and plateau pressures are better tailored to baby lung size than to ideal body weight. Although less information is available for the baby lung during spontaneous breathing efforts, the general principles regulating the safety of ventilation are also applicable under these conditions. PMID:26781952

  17. Effective pine bark composting with the Dome Aeration Technology

    SciTech Connect

    Trois, Cristina . E-mail: troisc@ukzn.ac.za; Polster, Andreas

    2007-07-01

    In South Africa garden refuse is primarily disposed of in domestic landfills. Due to the large quantities generated, any form of treatment would be beneficial for volume reduction, waste stabilization and resource recovery. Dome Aeration Technology (DAT) is an advanced process for aerobic biological degradation of garden refuse and general waste [Paar, S., Brummack, J., Gemende, B., 1999a. Advantages of dome aeration in mechanical-biological waste treatment. In: Proceedings of the 7th International Waste Management and Landfill Symposium, Cagliari, 4-8 October 1999; Paar, S., Brummack, J., Gemende, B., 1999b. Mechanical-biological waste stabilization by the dome aeration method. Environment Protection Engineering 25 (3/99). Mollekopf, N., Brummack, J., Paar, S., Vorster, K., 2002. Use of the Dome Aeration Technology for biochemical stabilization of waste prior to landfilling. In: Proceedings of the Wastecon 2002, Waste Congress and Exhibition, Durban, South Africa.]. It is a non-reactor open windrow composting process, with the main advantage being that the input material needs no periodic turning. A rotting time of only 3-4 months indicates the high efficiency. Additionally, the low capital/operational costs, low energy inputs and limited plant requirements provide potential for use in aerobic refuse stabilization. The innovation in the DAT process is the passive aeration achieved by thermally driven advection through open windrows caused by temperature differences between the degrading material and the outside environment. This paper investigates the application of Dome Aeration Technology to pine bark composting as part of an integrated waste management strategy. A full-scale field experiment was performed at the Bisasar Road Landfill Site in Durban to assess the influence of climate, waste composition and operational conditions on the process. A test windrow was constructed and measurements of temperature and airflow through the material were taken. The process

  18. BIOVENTING - Groundwater Aeration by Discontinuous Oxygen Gas Pulse Injections

    NASA Astrophysics Data System (ADS)

    Schirmer, M.

    2003-12-01

    Groundwater aeration by discontinuous oxygen gas pulse injections appears to be a promising concept for enhanced natural attenuation of dissolved contaminants that are susceptible for oxygenase enzyme attacks. Oxygen amendments facilitate indigenous microbiota to catabolize groundwater pollutants, such as aromatics, that are considered to be recalcitrant in absence of dissolved oxygen. As a rule, natural attenuation of many pollutants under aerobic conditions is considerably faster than under anaerobic conditions. Thus, enhancing the dissolved oxygen level appears to be worthwhile. In situ aeration of groundwater has been accomplished by air sparging, H2O2-supply, or by utilization of oxygen release compounds. However, continuous aeration of previously anaerobic groundwater is not desirable for several reasons: (a) economic efforts too high, (b) pollutant dislocation towards surface (desired only in air sparging), (c) risk of aquifer clogging (gas clogging, oxidation of ferrous iron, formation of bioslimes). In contrast, discontinuous oxygen gas sparging provides only for periodical groundwater aeration which is followed by microaerobic and suboxic conditions. Microaerobic conditions can prevail spatially (e.g., at plume fringes or within biofilms) or temporarily (e.g., at discontinuous bioventing). They still allow adapted bacteria to transform environmental pollutants to less toxic compounds, e.g., aromatic ring cleavage after dioxygenasis attack. Ring cleavage products, on the other hand, may be degraded more easily by anaerobic consortia than the initial aromatic compounds, making oxygen depletion periods highly intriguing in regard to an initiation of natural attenuation processes at plume fringes. In our work we outline the effect of oxygen depletion conditions on biodegradation of monchlorobenzene (MCB) as they occur subsequently to temporary aeration periods. For microaerobic conditions, relative to the oxygen supply, a stoichiometric transformation of MCB

  19. Aeration of hydroturbine discharges at TIMS Ford Dam

    SciTech Connect

    Harshbarger, E.D.; Mobley, M.H.; Brock, W.G.

    1995-12-31

    Tims Ford Dam located on the Elk River in middle Tennessee is a multipurpose project of the Tennessee Valley Authority (TVA) which provides flood control, water supply, and hydropower generation. Because of thermal stratification in the reservoir and biochemical processes, the hydroturbine discharges from Tims Ford have been historically low in dissolved oxygen (DO) content during several months of the year. To increase the DO of these discharges to a concentration level of 6 mg/L, a dual aeration system using both air injection into the turbine and oxygen injection through porous hoses in the turbine penstock has been installed. This paper describes the air and oxygen systems and presents the results of aeration system operation on DO and total dissolved gas in the turbine discharge and on hydroturbine efficiency.

  20. Sequentially aerated membrane biofilm reactors for autotrophic nitrogen removal: microbial community composition and dynamics

    PubMed Central

    Pellicer-Nàcher, Carles; Franck, Stéphanie; Gülay, Arda; Ruscalleda, Maël; Terada, Akihiko; Al-Soud, Waleed Abu; Hansen, Martin Asser; Sørensen, Søren J; Smets, Barth F

    2014-01-01

    Membrane-aerated biofilm reactors performing autotrophic nitrogen removal can be successfully applied to treat concentrated nitrogen streams. However, their process performance is seriously hampered by the growth of nitrite oxidizing bacteria (NOB). In this work we document how sequential aeration can bring the rapid and long-term suppression of NOB and the onset of the activity of anaerobic ammonium oxidizing bacteria (AnAOB). Real-time quantitative polymerase chain reaction analyses confirmed that such shift in performance was mirrored by a change in population densities, with a very drastic reduction of the NOB Nitrospira and Nitrobacter and a 10-fold increase in AnAOB numbers. The study of biofilm sections with relevant 16S rRNA fluorescent probes revealed strongly stratified biofilm structures fostering aerobic ammonium oxidizing bacteria (AOB) in biofilm areas close to the membrane surface (rich in oxygen) and AnAOB in regions neighbouring the liquid phase. Both communities were separated by a transition region potentially populated by denitrifying heterotrophic bacteria. AOB and AnAOB bacterial groups were more abundant and diverse than NOB, and dominated by the r-strategists Nitrosomonas europaea and Ca. Brocadia anammoxidans, respectively. Taken together, the present work presents tools to better engineer, monitor and control the microbial communities that support robust, sustainable and efficient nitrogen removal. PMID:24112350

  1. Sequentially aerated membrane biofilm reactors for autotrophic nitrogen removal: microbial community composition and dynamics.

    PubMed

    Pellicer-Nàcher, Carles; Franck, Stéphanie; Gülay, Arda; Ruscalleda, Maël; Terada, Akihiko; Al-Soud, Waleed Abu; Hansen, Martin Asser; Sørensen, Søren J; Smets, Barth F

    2014-01-01

    Membrane-aerated biofilm reactors performing autotrophic nitrogen removal can be successfully applied to treat concentrated nitrogen streams. However, their process performance is seriously hampered by the growth of nitrite oxidizing bacteria (NOB). In this work we document how sequential aeration can bring the rapid and long-term suppression of NOB and the onset of the activity of anaerobic ammonium oxidizing bacteria (AnAOB). Real-time quantitative polymerase chain reaction analyses confirmed that such shift in performance was mirrored by a change in population densities, with a very drastic reduction of the NOB Nitrospira and Nitrobacter and a 10-fold increase in AnAOB numbers. The study of biofilm sections with relevant 16S rRNA fluorescent probes revealed strongly stratified biofilm structures fostering aerobic ammonium oxidizing bacteria (AOB) in biofilm areas close to the membrane surface (rich in oxygen) and AnAOB in regions neighbouring the liquid phase. Both communities were separated by a transition region potentially populated by denitrifying heterotrophic bacteria. AOB and AnAOB bacterial groups were more abundant and diverse than NOB, and dominated by the r-strategists Nitrosomonas europaea and Ca. Brocadia anammoxidans, respectively. Taken together, the present work presents tools to better engineer, monitor and control the microbial communities that support robust, sustainable and efficient nitrogen removal. PMID:24112350

  2. Optimum air-demand ratio for maximum aeration efficiency in high-head gated circular conduits.

    PubMed

    Ozkan, Fahri; Tuna, M Cihat; Baylar, Ahmet; Ozturk, Mualla

    2014-01-01

    Oxygen is an important component of water quality and its ability to sustain life. Water aeration is the process of introducing air into a body of water to increase its oxygen saturation. Water aeration can be accomplished in a variety of ways, for instance, closed-conduit aeration. High-speed flow in a closed conduit involves air-water mixture flow. The air flow results from the subatmospheric pressure downstream of the gate. The air entrained by the high-speed flow is supplied by the air vent. The air entrained into the flow in the form of a large number of bubbles accelerates oxygen transfer and hence also increases aeration efficiency. In the present work, the optimum air-demand ratio for maximum aeration efficiency in high-head gated circular conduits was studied experimentally. Results showed that aeration efficiency increased with the air-demand ratio to a certain point and then aeration efficiency did not change with a further increase of the air-demand ratio. Thus, there was an optimum value for the air-demand ratio, depending on the Froude number, which provides maximum aeration efficiency. Furthermore, a design formula for aeration efficiency was presented relating aeration efficiency to the air-demand ratio and Froude number. PMID:25225935

  3. In situ nitrogen removal from leachate by bioreactor landfill with limited aeration

    SciTech Connect

    Shao Liming; He Pinjing Li Guojian

    2008-07-01

    The feasibility of simultaneous nitrification and denitrification in a bioreactor landfill with limited aeration was assessed. Three column reactors, simulating bioreactor landfill operations under anaerobic condition (as reference), intermittent forced aeration and enhanced natural aeration were hence established, where aerated columns passed through two phases, i.e., fresh landfill and well-decomposed landfill. The experimental results show that limited aeration decreased nitrogen loadings of leachate distinctly in the fresh landfill. In the well-decomposed landfill, the NH{sub 4}{sup +}-N of the input leachate could be nitrified completely in the aerated landfill columns. The nitrifying loadings of the column cross section reached 7.9 g N/m{sup 2} d and 16.9 g N/m{sup 2} d in the simulated landfill columns of intermittent forced aeration and enhanced natural aeration, respectively. The denitrification was influenced by oxygen distribution in the landfill column. Intermittent existence of oxygen in the landfill with the intermittent forced aeration was favorable to denitrify the NO{sub 2}{sup -}-N and NO{sub 3}{sup -}-N, indicated by the high denitrification efficiency (>99%) under the condition of BOD{sub 5}/TN of more than 5.4 in leachate; locally persistent existence of oxygen in the landfill with enhanced natural aeration could limit the denitrification, indicated by relatively low denitrification efficiency of about 75% even when the BOD{sub 5}/TN in leachate had an average of 7.1.

  4. Parameter optimization of unbaffled circular surface aeration tank.

    PubMed

    Kumar, Bimlesh; Rao, Achanta Ramakrishna; Patel, Ajey Kumar

    2011-01-01

    The efficiency of the surface aeration systems is generally governed by the geometric and dynamic parameters. The geometry is important because successful translation of the laboratory finding can be scaled up to field installations. Experimental optimization of the geometrical parameters (classical approach of one parameter variations at a time) has certain limitations, because it assumes a linear relationship among the various geometric parameters. In the real experimental process, it is not possible to vary all the parameters simultaneously. In such a case, the model of the system is built through computer simulation, assuming that the model will result in adequate determination of the optimum conditions for the real system. In this paper, two approaches have been used to model the phenomena in unbaffled circular surface aerators: i) Multiple regression and ii) Neural network. It has been found that neural network approach is showing better predictability compared to the multiple regression approach. In process of optimization, the pertinent dynamic parameter is divided into a finite number of segments over the entire range of observations. For each segment of the dynamic parameter, the neural network model is optimized for the geometrical parameters spanning over the entire range of observations. Thus each segment of the dynamic parameter has its set of optimal geometrical conditions. Results obtained are having less variation among them and they are very nearer to the experimental optimal conditions. Input parameter significance test of neural network model reveals that blade width of the rotor is the most significant geometric parameter for the aeration process. PMID:22324141

  5. The extent of the influence and flux estimation of volatile mercury from the aeration pool in a typical coal-fired power plant equipped with a seawater flue gas desulfurization system.

    PubMed

    Sun, Lumin; Feng, Lifeng; Yuan, Dongxing; Lin, Shanshan; Huang, Shuyuan; Gao, Liangming; Zhu, Yong

    2013-02-01

    Before being discharged, the waste seawater from the flue gas desulfurization system of coal-fired power plants contains a large amount of mercury, and is treated in aeration pools. During this aeration process, part of the mercury enters the atmosphere, but only very limited impact studies concerning this have been carried out. Taking a typical Xiamen power plant as an example, the present study targeted the elemental mercury emitted from the aeration pool. Concentrations of dissolved gaseous mercury as high as 1.14 ± 0.17 ng·L(-1) were observed in the surface waste seawater in the aeration pool, and gaseous elemental mercury (GEM) as high as 10.94 ± 1.89 ng·m(-3) was found in the air above the pool. To investigate the area affected by this GEM through air transfer, the total mercury in the dust and topsoil samples around the aeration pool were analyzed. Much higher values were found compared to those at a reference site. Environmental factors other than solar radiation had limited influence on the concentrations of the mercury species in the pool. A simulation device was built in our laboratory to study the flux of mercury from the aeration pool into the air. The results showed that more than 0.59 kg of mercury was released from the aeration pool every year, occupying 0.3% of the total mercury in the waste seawater. The transfer of mercury from water to air during the aeration pool and its environmental influence should not be ignored. PMID:23305917

  6. Lung Emergencies

    MedlinePlus

    ... Emergencies Cardiac Emergencies Eye Emergencies Lung Emergencies Surgeries Lung Emergencies People with Marfan syndrome can be at ... should be considered an emergency. Symptoms of sudden lung collapse (pneumothorax) Symptoms of a sudden lung collapse ...

  7. Lung Cancer

    MedlinePlus

    ... version of this page please turn Javascript on. Lung Cancer What is Lung Cancer? How Tumors Form The body is made ... button on your keyboard.) Two Major Types of Lung Cancer There are two major types of lung ...

  8. Lung metastases

    MedlinePlus

    Metastases to the lung; Metastatic cancer to the lung ... Metastatic tumors in the lungs are cancers that developed at other places in the body (or other parts of the lungs) and spread through the ...

  9. Detailed diesel exhaust characteristics including particle surface area and lung deposited dose for better understanding of health effects in human chamber exposure studies

    NASA Astrophysics Data System (ADS)

    Wierzbicka, Aneta; Nilsson, Patrik T.; Rissler, Jenny; Sallsten, Gerd; Xu, Yiyi; Pagels, Joakim H.; Albin, Maria; Österberg, Kai; Strandberg, Bo; Eriksson, Axel; Bohgard, Mats; Bergemalm-Rynell, Kerstin; Gudmundsson, Anders

    2014-04-01

    Several diesel exhaust (DE) characteristics, comprising both particle and gas phase, recognized as important when linking with health effects, are not reported in human chamber exposure studies. In order to understand effects of DE on humans there is a need for better characterization of DE when performing exposure studies. The aim of this study was to determine and quantify detailed DE characteristics during human chamber exposure. Additionally to compare to reported DE properties in conducted human exposures. A wide battery of particle and gas phase measurement techniques have been used to provide detailed DE characteristics including the DE particles (DEP) surface area, fraction and dose deposited in the lungs, chemical composition of both particle and gas phase such as NO, NO2, CO, CO2, volatile organic compounds (including aldehydes, benzene, toluene) and polycyclic aromatic hydrocarbons (PAHs). Eyes, nose and throat irritation effects were determined. Exposure conditions with PM1 (<1 μm) mass concentration 280 μg m-3, number concentration 4 × 105 cm-3 and elemental to total carbon fraction of 82% were generated from a diesel vehicle at idling. When estimating the lung deposited dose it was found that using the size dependent effective density (in contrast to assuming unity density) reduced the estimated respiratory dose by 132% by mass. Accounting for agglomerated structure of DEP prevented underestimation of lung deposited dose by surface area by 37% in comparison to assuming spherical particles. Comparison of DE characteristics reported in conducted chamber exposures showed that DE properties vary to a great extent under the same DEP mass concentration and engine load. This highlights the need for detailed and standardized approach for measuring and reporting of DE properties. Eyes irritation effects, most probably caused by aldehydes in the gas phase, as well as nose irritation were observed at exposure levels below current occupational exposure limit

  10. Effect of Aeration and Circulation Treatment of Effluent on Wastewater Purification Functions of a Planted Canal

    NASA Astrophysics Data System (ADS)

    Tsuji, Morio; Yamada, Kazuhiro; Hiratsuka, Akira

    Water purification characteristic evaluation was done for adding aeration and circulation to a canal planted with Carex dispalata, which is a Japanese native species whose height does not obstruct the view. Circulation improved the BOD removal efficiency, irrespective of the use of aeration. Aeration improved the BOD removal efficiency in the condition of circulation ON. The BOD removal rate without any circulation was 15g·m-2·d-1, which was the maximum, suggesting that it can be raised higher than 20g·m-2·d-1 through the use of aeration and circulation. The D-BOD removal effect is high. Therefore, removal of the organic pollution load by bacteria increased. The nitrogen removal efficiency did not increase because nitrification by aeration did not advance. Instead of energy-intensive aeration, it is necessary to consider the oxidative capacity of nitrification.

  11. The effects of agitation and aeration on the production of gluconic acid by Aspergillus niger

    SciTech Connect

    Dronawat, S.N.; Svihla, C.K.; Hanley, T.R.

    1995-12-31

    The effects of agitation and aeration in the production of gluconic acid by Aspergillus niger from a glucose medium were investigated. Experiments were conducted at aeration rates of 5.0 and 10.0 L/min. Four different agitation speeds were investigated for each aeration rate. Gluconic acid concentration and biomass concentration were analyzed, and the rate of consumption of substrate by A. niger was noted. The main purpose of this work was to find the optimal conditions of agitation and aeration for the growth of A. niger and production of gluconic acid in submerged culture in a batch fermentor at a bench-top scale. The oxygen-transfer rates at different agitation and aeration rates were calculated. The gluconic acid concentration and rate of growth of A. niger increased with increase in the agitation and aeration rates.

  12. Improved oxygen mass transfer modeling for diffused or subsurface aeration systems

    SciTech Connect

    McWhirter, J.R.; Hutter, J.C. . Dept. of Chemical Engineering)

    1988-01-01

    The mass transfer analysis of the oxygen transfer performance of diffused air or subsurface mechanical aeration systems has progressed very little over the past twenty years. The ASCE Standard Method for determination of the oxygen mass transfer performance as applied to a diffused or subsurface aeration systems is based on a greatly over-simplified mass transfer model. Although the ASCE Standard can be used to empirically evaluate point performance conditions, it is not suitable for prediction of the performance of diffused aeration systems under changing operating or environmental conditions. A new oxygen mass transfer model has been developed which is a fundamentally more rigorous description of the actual mass transfer process in diffused aeration systems. This model can be confidently used to predict aerator performance under changing operation and environmental conditions and is easily adapted to numerical solution on a computer for routing aeration system performance evaluation as well as process design. The model is presented in this book.

  13. Lung cancer

    SciTech Connect

    Aisner, J.

    1985-01-01

    This book contains 13 chapters. Some of the chapter titles are: The Pathology of Lung Cancer; Radiotherapy for Non-Small-Cell Cancer of the Lung; Chemotherapy for Non-Small-Cell Lung Cancer; Immunotherapy in the Management of Lung Cancer; Preoperative Staging and Surgery for Non-Small-Cell Lung Cancer; and Prognostic Factors in Lung Cancer.

  14. Effects of aeration position on organics, nitrogen and phosphorus removal in combined oxidation pond-constructed wetland systems.

    PubMed

    Wang, Xiaoou; Tian, Yimei; Zhao, Xinhua; Peng, Sen; Wu, Qing; Yan, Lijian

    2015-12-01

    Given that few studies investigated the effects of aeration position (AP) on the performance of aerated constructed wetlands, the aim of this study was to evaluate the effects of AP on organics, nitrogen and phosphorus removal in lab-scale combined oxidation pond-constructed wetland (OP-CW) systems. Results showed that middle aeration allowed the CW to possess more uniform oxygen distribution and to achieve greater removals of COD and NH3-N, while the CW under bottom aeration and surface aeration demonstrated more distinct stratification of oxygen distribution and surface aeration brought about better TN removal capacity for the OP-CW system. However, no significant influence of artificial aeration or AP on TP removal was observed. Overall, AP could significantly affect the spatial distribution of dissolved oxygen by influencing the oxygen diffusion paths in aerated CWs, thereby influencing the removal of pollutants, especially organics and nitrogen, which offers a reference for the design of aerated CWs. PMID:26360599

  15. Low-cost/low-technology aeration techniques for removing radon from drinking water. Environmental research brief

    SciTech Connect

    Kinner, N.E.; Lessard, C.E.; Schell, G.S.; Fox, K.R.

    1987-09-01

    Simple treatment techniques designed as low-cost/low-technology aeration techniques were investigated as to determine their effectiveness for the removal of radon from drinking water. The techniques investigated consisted of flow through storage and minimal aeration in various configurations and were found to be effective in varying degrees for the reduction of radon. These low-cost/low-technology aeration techniques may be easily applied in small communities.

  16. CFD study to determine the optimal configuration of aerators in a full-scale waste stabilization pond.

    PubMed

    Alvarado, Andres; Vesvikar, Mehul; Cisneros, Juan F; Maere, Thomas; Goethals, Peter; Nopens, Ingmar

    2013-09-01

    Aerated lagoons (ALs) are important variants of the pond wastewater treatment technology that have not received much attention in the literature. The hydraulic behaviour of ALs and especially the Facultative aerated lagoons (FALs) is very complex since the aeration in these systems is designed for oxygen transfer but not necessarily to create complete mixing. In this work, the energy expenditure of the aerators was studied by means of a scenario analysis. 3D CFD models (one phase and multiphase) of a 3 ha FAL in a waste stabilization pond system in Cuenca (Ecuador) were built for different configurations of aerators. The thrust produced by the aerators was modelled by an external momentum source applied as velocity vectors into the pond fluid. The predictions of a single phase model were in satisfactory agreement with experimental results. Subsequently, a scenario analysis assessing several aeration schemes with different numbers of aerators in operation were tested with respect to velocity profiles and residence time distribution (RTD) curves. This analysis showed that the aeration scheme with all 10 aerators switched on produces a similar hydraulic behaviour compared to using only 6 or 8 aerators. The current operational schemes comprise of switching off some aerators during the peak hours of the day and operating all 10 aerators during night. This current practice could be economically replaced by continuously operating 4 or 6 aerators without significantly affecting the overall mixing. Furthermore, a continuous mixing regime minimises the sediment oxygen demand enhancing the oxygen levels in the pond. PMID:23764602

  17. Effect of influent aeration on removal of organic matter from coffee processing wastewater in constructed wetlands.

    PubMed

    Rossmann, Maike; Matos, Antonio Teixeira; Abreu, Edgar Carneiro; Silva, Fabyano Fonseca; Borges, Alisson Carraro

    2013-10-15

    The aim of the present study was to evaluate the influence of aeration and vegetation on the removal of organic matter in coffee processing wastewater (CPW) treated in 4 constructed wetlands (CWs), characterized as follows: (i) ryegrass (Lolium multiflorum) cultivated system operating with an aerated influent; (ii) non-cultivated system operating with an aerated influent, (iii) ryegrass cultivated system operating with a non-aerated influent; and (iv) non-cultivated system operating with a non-aerated influent. The lowest average chemical oxygen demand (COD), biochemical oxygen demand (BOD) and total suspended solids (TSS) removal efficiencies of 87, 84 and 73%, respectively, were obtained in the ryegrass cultivated system operating with a non-aerated influent. However, ryegrass cultivation did not influence the removal efficiency of organic matter. Artificial aeration of the CPW, prior to its injection in the CW, did not improve the removal efficiencies of organic matter. On other hand it did contribute to increase the instantaneous rate at which the maximum COD removal efficiency was reached. Although aeration did not result in greater organic matter removal efficiencies, it is important to consider the benefits of aeration on the removal of the other compounds. PMID:23892132

  18. Method and apparatus for energy efficient self-aeration in chemical, biochemical, and wastewater treatment processes

    DOEpatents

    Gao, Johnway [Richland, WA; Skeen, Rodney S [Pendleton, OR

    2002-05-28

    The present invention is a pulse spilling self-aerator (PSSA) that has the potential to greatly lower the installation, operation, and maintenance cost associated with aerating and mixing aqueous solutions. Currently, large quantities of low-pressure air are required in aeration systems to support many biochemical production processes and wastewater treatment plants. Oxygen is traditionally supplied and mixed by a compressor or blower and a mechanical agitator. These systems have high-energy requirements and high installation and maintenance costs. The PSSA provides a mixing and aeration capability that can increase operational efficiency and reduce overall cost.

  19. Landfill aeration in the framework of a reclamation project in Northern Italy.

    PubMed

    Raga, Roberto; Cossu, Raffaello

    2014-03-01

    In situ aeration by means of the Airflow technology was proposed for landfill conditioning before landfill mining in the framework of a reclamation project in Northern Italy. A 1-year aeration project was carried out on part of the landfill with the objective of evaluating the effectiveness of the Airflow technology for landfill aerobization, the evolution of waste biological stability during aeration and the effects on leachate and biogas quality and emissions. The main outcomes of the 1-year aeration project are presented in the paper. The beneficial effect of the aeration on waste biological stability was clear (63% reduction of the respiration index); however, the effectiveness of aeration on the lower part of the landfill is questionable, due to the limited potential for air migration into the leachate saturated layers. During the 1-year in situ aeration project approx. 275 MgC were discharged from the landfill body with the extracted gas, corresponding to 4.6 gC/kgDM. However, due to the presence of anaerobic niches in the aerated landfill, approx. 46% of this amount was extracted as CH4, which is higher than reported in other aeration projects. The O2 conversion quota was lower than reported in other similar projects, mainly due to the higher air flow rates applied. The results obtained enabled valuable recommendations to be made for the subsequent application of the Airflow technology to the whole landfill. PMID:24411985

  20. Bioreactor tests preliminary to landfill in situ aeration: A case study

    SciTech Connect

    Raga, Roberto; Cossu, Raffaello

    2013-04-15

    Highlights: ► Carbon and nitrogen mass balances in aerated landfill simulation reactors. ► Waste stabilization in aerated landfill simulation reactors. ► Effect of temperature on biodegradation processes in aerated landfills. - Abstract: Lab scale tests in bioreactor were carried out in the framework of the characterization studies of a landfill where in situ aeration (possibly followed by landfill mining) had been proposed as part of the novel waste management strategy in a region in northern Italy. The tests were run to monitor the effects produced by aerobic conditions at different temperatures on waste sampled at different depths in the landfill, with focus on the carbon and nitrogen conversion during aeration. Temperatures ranging from 35 to 45 °C were chosen, in order to evaluate possible inhibition of biodegradation processes (namely nitrification) at 45 °C in the landfill. The results obtained showed positive effects of the aeration on leachate quality and a significant reduction of waste biodegradability. Although a delay of biodegradation processes was observed in the reactor run at 45 °C, biodegradation rates increased after 2 months of aeration, providing very low values of the relevant parameters (as in the other aerated reactors) by the end of the study. Mass balances were carried out for TOC and N-NH{sub 4}{sup +}; the findings obtained were encouraging and provided evidence of the effectiveness of carbon and nitrogen conversion processes in the aerated landfill simulation reactors.

  1. Asbestos lung burden and asbestosis after occupational and environmental exposure in an asbestos cement manufacturing area: a necropsy study

    PubMed Central

    Magnani, C.; Mollo, F.; Paoletti, L.; Bellis, D.; Bernardi, P.; Betta, P.; Botta, M.; Falchi, M.; Ivaldi, C.; Pavesi, M.

    1998-01-01

    OBJECTIVE: The largest Italian asbestos cement factory had been active in Casale Monferrato until 1986: in previous studies a substantial increase in the incidence of pleural mesothelioma was found among residents without occupational exposure to asbestos. To estimate exposure to asbestos in the population, this study evaluated the presence of histological asbestosis and the lung burden of asbestos fibres (AFs) and asbestos bodies (ABs). METHODS: The study comprises the consecutive series of necropsies performed at the Hospital of Casale Monferrato between 1985 and 1988. A sample of lung parenchima was collected and stored for 48 out of 55 necropsies. The AF concentration was measured with a TEM electron microscope with x ray mineralogical analysis. The ABs were counted and fibrosis evaluated by optical microscopy. The nearest relative of each subject was interviewed on occupational and residential history. Mineralogical and histological analyses and interviews were conducted in 1993-4. RESULTS: Statistical analyses included 41 subjects with AF, AB count, and interview. Subjects without occupational exposure who ever lived in Casale Monferrato had an average concentration of 1500 AB/g dried weight (gdw); Seven of 18 presented with asbestosis or small airway lung disease (SAL). G2 asbestosis was diagnosed in two women with no occupational asbestos exposure. One of them had been teaching at a school close to the factory for 12 years. Ten subjects had experienced occupational asbestos exposure, seven in asbestos cement production: mean concentrations were 1.032 x 10(6) AF/gdw and 96,280 AB/gdw. Eight of the 10 had asbestosis or SAL. CONCLUSION: The high concentration of ABs and the new finding of environmental asbestosis confirm that high asbestos concentration was common in the proximity of the factory. Subjects not occupationally exposed and ever living in Casale Monferrato tended to have higher AB concentration than subjects never living in the town (difference not

  2. Pseudomonads Rule Degradation of Polyaromatic Hydrocarbons in Aerated Sediment

    PubMed Central

    Wald, Jiri; Hroudova, Miluse; Jansa, Jan; Vrchotova, Blanka; Macek, Tomas; Uhlik, Ondrej

    2015-01-01

    Given that the degradation of aromatic pollutants in anaerobic environments such as sediment is generally very slow, aeration could be an efficient bioremediation option. Using stable isotope probing (SIP) coupled with pyrosequencing analysis of 16S rRNA genes, we identified naphthalene-utilizing populations in aerated polyaromatic hydrocarbon (PAH)-polluted sediment. The results showed that naphthalene was metabolized at both 10 and 20°C following oxygen delivery, with increased degradation at 20°C as compared to 10°C—a temperature more similar to that found in situ. Naphthalene-derived 13C was primarily assimilated by pseudomonads. Additionally, Stenotrophomonas, Acidovorax, Comamonas, and other minor taxa were determined to incorporate 13C throughout the measured time course. The majority of SIP-detected bacteria were also isolated in pure cultures, which facilitated more reliable identification of naphthalene-utilizing populations as well as proper differentiation between primary consumers and cross-feeders. The pseudomonads acquiring the majority of carbon were identified as Pseudomonas veronii and Pseudomonas gessardii. Stenotrophomonads and Acidovorax defluvii, however, were identified as cross-feeders unable to directly utilize naphthalene as a growth substrate. PAH degradation assays with the isolated bacteria revealed that all pseudomonads as well as Comamonas testosteroni degraded acenaphthene, fluorene, and phenanthrene in addition to naphthalene. Furthermore, P. veronii and C. testosteroni were capable of transforming anthracene, fluoranthene, and pyrene. Screening of isolates for naphthalene dioxygenase genes using a set of in-house designed primers for Gram-negative bacteria revealed the presence of such genes in pseudomonads and C. testosteroni. Overall, our results indicated an apparent dominance of pseudomonads in the sequestration of carbon from naphthalene and potential degradation of other PAHs upon aeration of the sediment at both 20 and

  3. Fecal-coliform bacteria in extended-aeration plant sludge

    SciTech Connect

    Anderson, M.; Kester, G.; Arant, S.

    1998-07-01

    The concentration of fecal-coliform bacteria in sludge from extended-aeration plants was analyzed for compliance with new state and federal land application requirements. This study was initiated to determine if additional digestion would be necessary for plants to meet the new pathogen standards of less than 2 million CFU per gm of solids. Sludge was found to contain less than 2 million fecal coliform bacteria/gm of sludge as a result of a combination or aerobic digestion and/or long term storage.

  4. Pulverizing aeration as a method of lakes restoration

    NASA Astrophysics Data System (ADS)

    Kaczorowska, E.; Podsiadłowski, S.

    2012-04-01

    The principal threat to lakes of the temperate zone is posed by factors accelerating their eutrophication and causing marked deoxygenation of the deeper layers of water, mainly the hypo- and metalimnion. Among their effects are frequent phytoplankton blooms, including those of blue-green algae, and general deterioration of water quality also affecting the abundance and health status of fish. The chief concern is a disturbed proportion between the amount of complex chemical compounds, especially organic, and the oxygen content of lake waters. Natural processes of water oxygenation are not too intensive, because they are practically limited to the epilimnion layer, connected as they are with the activity of aquatic plants of the littoral and sublittoral zone (which tends to disappear in contaminated lakes) and wind energy (the effect of waving). In summer conditions, with a relatively great chemical activity of bottom deposits, the intensity of those processes is usually inadequate. Hence, in 1995 a research was launched in the Institute of Agricultural Engineering of the Agricultural University in Poznań on an integrated lake restoration technology whose core was a self-powered aerator capable of oxygenating also the bottom layers of water (the hypolimnion) of deep lakes. The aerator uses energy obtained from a Savonius rotor mainly to diffuse gases: to release hydrogen sulphide, which usually saturates the hypolimnion water completely, and then to saturate this water with oxygen. Even early studies showed the constructed device to be highly efficient in improving oxygen conditions in the bottom zone. They also made it clear that it should be equipped with an autonomous system designed to inactivate phosphorus, one of the principal factors determining the rate of lake degradation. In 2003 the first wind-driven pulverising aerator equipped with such a system was installed in Town Lake in Chodzież. The aim of this work is to present the principles of operation of a

  5. Sidestream Elevated Pool Aeration, a Technology for Improving Water Quality in Urban Rivers

    NASA Astrophysics Data System (ADS)

    Motta, D.; Garcia, T.; Abad, J. D.; Bombardelli, F. A.; Waratuke, A.; Garcia, M. H.

    2010-12-01

    Dissolved Oxygen (DO) levels are frequently depleted in rivers located in urban areas, as in the case of the Matanza-Riachuelo River in Buenos Aires, Argentina. This stream receives both domestic and industrial loads which have received minor or no treatment before being discharged into the water body. Major sources of pollution include, but are not limited, to leather and meat packing industries. Additionally, deep slow moving water in the river is associated with limited reaeration and facilitates deposition of organic-rich sediment, therefore exacerbating the DO consumption through sediment oxygen demand. In this study we assessed the efficiency of Sidestream Elevated Pool Aeration (SEPA) stations as a technology for alleviating conditions characterized by severely low DO levels. A SEPA station takes water from the stream at low DO concentrations, through a screw pump; then, water is transported to an elevated pool from where it flows over a series of weirs for water reaeration; finally, the aerated water is discharged back into the river sufficiently downstream from the intake point. This system mimics a phenomenon that occurs in mountain streams, where water is purified by bubbling over rocks. The impact of the use of SEPA stations on the DO concentrations in the Matanza-Riachuelo River was evaluated at both local and reach scales: this was done by deploying and monitoring an in situ pilot SEPA station, and by performing numerical modeling for the evaluation of the hydrodynamics in the SEPA station and the water quality in the reach where SEPA stations are planned to be implemented. An efficiency of aeration of 99% was estimated from DO measurements in the pilot SEPA, showing the potential of this technology for DO recovery in urban streams. Three-dimensional hydrodynamic modeling, besides assisting in the design of the pilot SEPA, has allowed for designing a prototype SEPA to be built soon. Finally, one-dimensional water quality modeling has provided the

  6. Mineralogical and compositional characteristics of Late Permian coals from an area of high lung cancer rate in Xuan Wei, Yunnan, China: Occurrence and origin of quartz and chamosite

    USGS Publications Warehouse

    Dai, S.; Tian, L.; Chou, C.-L.; Zhou, Y.; Zhang, M.; Zhao, L.; Wang, Jingyuan; Yang, Z.; Cao, H.; Ren, D.

    2008-01-01

    Some townships in Xuan Wei County, Yunnan Province, have one of the highest lung cancer mortality rates in China and the epidemic disease in the area has generally been attributed to the polycyclic aromatic hydrocarbons (PAHs) released from domestic coal burning. However, the cancer-causing culprit is not settled as Tian [Tian, L., 2005. Coal Combustion Emissions and Lung Cancer in Xuan Wei, China. Ph.D. thesis, University of California, Berkeley.] found nanometer quartz in these coals, soot emissions, and lung cancer tissues. We have conducted mineralogical and geochemical studies of the coals from Xuan Wei for the purpose of shedding light on the minerals which may be related to the epidemic lung cancer. In this paper, abundances, modes of occurrence, and origins of minerals and elements in the coals from two mines in Xuan Wei have been studied using optical microscope, low-temperature ashing, X-ray diffraction analysis, scanning electron microscope equipped with energy-dispersive X-ray spectrometer, and inductively-coupled plasma mass spectrometry. The minerals in the coals are mainly composed of quartz, chamosite, kaolinite, and calcite. The particle size of quartz is rather small, mostly less than 20????m and it is of authigenic origin. Chamosite occurs mainly as cell-fillings. The occurrence of quartz and chamosite indicates that they were derived from the hydrothermal fluids. Epigenetic calcite is derived from calcic fluids. Kaolinite is derived mainly from sediment source region of Kangdian Oldland to the west of coal basin. The composition of Xuan Wei coal is high in SiO2, Fe2O3, TiO2, CaO, MnO, V, Co, Ni, Cu, and Zn. The high SiO2 content is attributed to quartz, and the Fe2O3 content to chamosite. The high Mn and low Mg contents in the coal indicate the inputs of hydrothermal fluids. CaO occurs mainly in epigenetic calcite. Elements Ti, Co, Ni, Cu, Zn, and rare earth elements were derived from the basaltic rocks at sediment source region. ?? 2008

  7. The use of bottle caps as submerged aerated filter medium.

    PubMed

    Damasceno de Oliveira, Laurence; Motlagh, Amir Mohaghegh; Goel, Ramesh; de Souza Missagia, Beatriz; Alves de Abreu Filho, Benício; Lautenschlager, Sandro Rogério

    2014-01-01

    In this study, a submerged aerated filter (SAF) using bottle caps as a support medium was evaluated. The system was fed with effluent from an upflow anaerobic sludge blanket system at ETE 2-South wastewater treatment plant, under different volumetric organic load rates (VOLRs). The population of a particular nitrifying microbial community was assessed by fluorescent in situ hybridization with specific oligonucleotide probes. The system showed an average removal of chemical oxygen demand (COD) equal to 76% for VOLRs between 2.6 and 13.6 kg COD m(-3)_media.day(-1). The process of nitrification in conjunction with the removal of organic matter was observed from applying VOLRs lower than 5.5 kg COD m(-3)_media.day(-1) resulting in 78% conversion of NH4(+)-N. As the applied organic load was reduced, an increase in the nitrifying bacteria population was observed compared with total 4'-6-diamidino-2-phenylindole (DAPI) stained cells. Generally, SAF using bottle caps as a biological aerated filter medium treating wastewater from an anaerobic system showed promising removal of chemical oxygen demand (COD) and conversion of NH4(+)-N. PMID:24718345

  8. Final Report: Retrofit Aeration System (RAS) for Francis Turbine

    SciTech Connect

    Alan Sullivan; DOE Project Officer Keith Bennett

    2006-08-01

    Osage Plant and Bagnell Dam impounds the Osage River forming the Lake of the Ozarks in Missouri. Since it is nearly 100 feet deep, the lake stratifies during the summer months causing low DO water to be discharged into the Osage river below the dam. To supplement DO, the turbines are vented during the low DO season. AmerenUE is continually researching new methods of DO enhancement. New turbines, manufactured by American Hydro Corporation, were installed in Units 3 & 5 during the spring of 2002. Additional vent capacity and new nosecones were included in the new turbine design. The retrofit aeration system is an attempt to further enhance the DO in the tailrace by installation of additional venting capability on Unit 6 (not upgraded with new turbine) and refining design on special nosecones which will be mounted on both Unit 3 (upgraded turbine) and Unit 6. Baseline DO testing for Units 3 & 6 was conducted mid August, 2002. This data wascompared to further tests planned for the summer of 2003 and 2004 after installation of the retrofit aeration system.

  9. Research and design activities in support of the Chicago underflow plan McCook reservoir aeration system

    SciTech Connect

    Sorn, L.M.

    1998-07-01

    This paper discussed activities being performed in support of the aeration system design for one of the three terminal storage reservoirs associated with the Chicago Underflow Plan, a project proposed to minimize combined sewer flooding problems in the Chicago Metropolitan Area. The activities included: implementation of a combined sewage sampling plan, water quality modeling of the combined sewage as it flows through the deep tunnel, the development of a three-dimensional hydrodynamic model, and the execution of diffusion tests both in tanks and in the field. Preliminary results from the combined sewage sampling program, oxygen transfer test, and velocity tests are provided.

  10. Evaluation of re-aeration equations for river Ghataprabha, Karnataka, India and development of refined equation.

    PubMed

    Kalburgi, P B; Jha, R; Ojha, C S P; Deshannavar, U B

    2015-01-01

    Stream re-aeration is an extremely important component to enhance the self-purification capacity of streams. To estimate the dissolved oxygen (DO) present in the river, estimation of re-aeration coefficient is mandatory. Normally, the re-aeration coefficient is expressed as a function of several stream variables, such as mean stream velocity, shear stress velocity, bed slope, flow depth and Froude number. Many empirical equations have been developed in the last years. In this work, 13 most popular empirical re-aeration equations, used for re-aeration prediction, have been tested for their applicability in Ghataprabha River system, Karnataka, India, at various locations. Extensive field data were collected during the period March 2008 to February 2009 from seven different sites located in the river to observe re-aeration coefficient using mass balance approach. The performance of re-aeration equations have been evaluated using various error estimations, namely, the standard error (SE), mean multiplicative error (MME), normalized mean error (NME) and correlation statistics. The results show that the predictive equation developed by Jha et al. (Refinement of predictive re-aeration equations for a typical Indian river. Hydrological Process. 2001;15(6):1047-1060), for a typical Indian river, yielded the best agreement with the values of SE, MME, NME and correlation coefficient r. Furthermore, a refined predictive equation has been developed for river Ghataprabha using least-squares algorithm that minimizes the error estimates. PMID:25409586

  11. Biodegradation of diesel oil and gasoline contaminated effluent employing intermittent aeration.

    PubMed

    Vieira, P A; Vieira, R B; Faria, S; Ribeiro, E J; Cardoso, V L

    2009-09-15

    We examined the effects of aeration interval and agitation speed in an effort to optimize the biodegradation of effluent contaminated with diesel oil and gasoline. The biodegradation process employed a C(1) mixed culture and intermittent aeration. Optimization was performed using central composite design (CCD). The independent variables were aeration interval (X(1)) and agitation speed (X(2)) and the dependent variable was the degree of removal of total petroleum hydrocarbons (TPH). The optimum aeration interval (33h) and agitation speed (110rpm) resulted in TPH removal of 75.9% after 3 days. Five hydrocarbons classes were identified using gas chromatography: paraffins, isoparaffins, olefins, naphthenics, and aromatics. The following reductions were observed: 91.8% for the paraffins, 83.3% for the isoparaffins, 80.9% for the olefins, 39.3% for the naphthenics, and 80.9% for the aromatics. In comparative studies performed under constant aeration (CA), without aeration (WA), and intermittent aeration (IA) conditions, intermittent aeration resulted in the highest TPH removals, with 90% reduction after 22 days. Under the IA condition, the degradation percentages were 99.6% for the paraffins, 94% for the isoparaffins, 95.4% for the olefins, 70.8 for the naphthenics, and 83.4% for the aromatics. PMID:19356851

  12. Aerated Shewanella oneidensis in Continuously-fed Bioelectrochemical Systems for Power and Hydrogen Production

    Technology Transfer Automated Retrieval System (TEKTRAN)

    We studied the effects of aeration of Shewanella oneidensis on potentiostatic current production, iron(III) reduction, hydrogen production in a microbial electrolysis cell, and electric power generation in a microbial fuel cell. The potentiostatic performance of aerated S. oneidensis was considerab...

  13. Evaluating aeration techniques for decreasing phosphorus export from grasslands receiving manure

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Given that surface-applied manures can contribute to phosphorus (P) in runoff, a study was conducted to examine mechanical aeration of grasslands for reducing P transport by increasing infiltration of rainfall and binding of P with soil minerals. The effects of three aeration treatments and a contr...

  14. Dissolved oxygen control of mechanical aerators at the Rensselaer county wastewater treatment plant. Final report

    SciTech Connect

    Wurtenberger, F.J.; Biski, W.K.; Guagno, J.A.

    1994-02-01

    The report describes the results of testing dissolved oxygen analyzers to control operation of mechanical aerators at the Rensselaer County Sewer District Wastewater Treatment Plant and reduce the amount of energy uses while maintaining or enhancing biological treatment. Current electricity costs are more than $300,000 annually for aeration in the activated sludge process. Motors for the aerators are manually controlled between high and low speed. It is expected that energy consumption will be reduced by using automatic controllers that change the speed of the aerators in response to the concentration of dissolved oxygen in the aeration basins. The project had three objectives; to test several manufacturers` dissolved oxygen analyzers at various locations within the aeration basins at the Rensselaer County Sewer District Wastewater Treatment Plant for accuracy, reliability, response time, and maintenance requirements; to install one manufacturer`s equipment in the aeration basins and operate the aerators either automatically or manually in response to dissolved oxygen readings; and to record plant operating and energy use data to determine whether the dissolved oxygen analyzers and controls were cost-effective and saved energy.

  15. Lung mass, right upper lung - chest x-ray (image)

    MedlinePlus

    This picture is a chest x-ray of a person with a lung mass. This is a front view, where the lungs are the two dark areas and ... visible in the middle of the chest. The x-ray shows a mass in the right upper lung, ...

  16. Lung mass, right upper lung - chest x-ray (image)

    MedlinePlus

    ... chest x-ray of a person with a lung mass. This is a front view, where the lungs are the two dark areas and the heart ... ray shows a mass in the right upper lung, indicated with the arrow (seen on the left ...

  17. Programmed death-1 ligand 1 and 2 are highly expressed in pleomorphic carcinomas of the lung: Comparison of sarcomatous and carcinomatous areas.

    PubMed

    Kim, Sehui; Kim, Moon-Young; Koh, Jaemoon; Go, Heounjeong; Lee, Dong Soo; Jeon, Yoon Kyung; Chung, Doo Hyun

    2015-11-01

    Pleomorphic carcinoma (PC) of the lung is a rare type of poorly differentiated non-small cell lung carcinoma (NSCLC) that belongs to sarcomatoid carcinoma (SC). It exhibits aggressive behaviour and resistance to chemotherapy and radiotherapy. Recently, immunotherapy targeting the programmed death-1 (PD-1)/PD ligand 1 (PD-L1) pathway has demonstrated favourable clinical outcomes in NSCLC. However, the expression patterns of PD-1-related molecules in pulmonary PC remain elusive. PD-L1 and PD-L2 expression was estimated in 41 cases of PC using immunohistochemistry. CD8(+) and PD-1(+) tumour-infiltrating lymphocytes (TILs) were also evaluated. PD-L1 and PD-L2 were highly expressed in pulmonary PCs (90.2% [37/41)]; 87.8% [36/41]). The amount of CD8(+) or PD-1(+) TILs and the ratio of PD-1(+)/CD8(+) TILs in PC were higher in males, smokers and older patients. PD-L1-positive PCs were infiltrated by higher numbers of CD8(+) TILs compared to PD-L1-negative cases (P=0.006). Of note, PD-L1 expression in pulmonary PCs was significantly higher in sarcomatous areas than in the carcinomatous portion (P=0.006). PC patients with a high ratio of PD-1(+)/CD8(+) TILs showed a shorter progression-free survival (P=0.036), whereas PD-L1 and PD-L2 expression had no prognostic implications. Our study demonstrates that pulmonary PCs very frequently express PD-L1 and PD-L2. Moreover, their expression is higher in sarcomatous cells than in carcinomatous areas. Thus, targeting the PD-1/PD-L1 pathway may represent a potential therapeutic candidate for this aggressive tumour. PMID:26329973

  18. Effects of intermittent aeration on pollutants removal in subsurface wastewater infiltration system.

    PubMed

    Pan, Jing; Fei, Hexin; Song, Siyu; Yuan, Fang; Yu, Long

    2015-09-01

    In this study, the pollutant removal performances in two pilot-scale subsurface wastewater infiltration systems (SWISs) with and without intermittent aeration were investigated. Matrix oxidation reduction potential (ORP) results showed that intermittent aeration well developed aerobic conditions in upper matrix and anoxic or anaerobic conditions in the subsequent sections, which resulted in high NH4(+)-N and TN removal. Moreover, intermittent aeration increased removal rates of COD and TP. Microbial populations and enzyme activities analysis proved that intermittent aeration not only obviously boosted the growth and reproduction of bacteria, fungus, actinomyces, nitrifying bacteria and denitrifying bacteria, but also successfully increased nitrate reductase (NR) and nitrite reductase (NIR) in the depth of 80 and 110 cm. The results suggest that the intermittent aeration could be a widespread research and application strategy for achieving the high removal performance in SWISs. PMID:26004389

  19. Heavy metal release from metal-sulfide contaminated lake sediments exposed to artificial aeration

    SciTech Connect

    Schaumloffel, J.C.; Filby, R.H.; Moore, B.C.

    1995-12-01

    Hypolimnetic aeration (a form of artificial aeration) has gained popularity in recent years as a lake restoration and management tool. The addition of oxygen to eutrophic lakes by hypolimnetic aeration has been shown to increase overall water quality, without disturbing thermal stratification. The effects of increasing dissolved oxygen levels by aeration on the chemistry of heavy metals in lakes where the sediments are contaminated and the possible repercussions, however, have yet to be investigated. In this laboratory study, sediments collected from a lake contaminated with metal-sulfides were exposed to various levels of dissolved oxygen in the overyling water column. concentrations of zinc, cadmium, and lead in the water column were shown to increase concomitantly with increasing concentrations of sulfate in the water as aeration progressed. The effects of varying concentrations of dissolved oxygen, as well as other factors effecting the availability of previously insoluble heavy metals will be discussed.

  20. Distinct epithelial growth factor receptor mutation profile in non-small-cell lung cancer patients from the Xuanwei area of China

    PubMed Central

    CHEN, YUN; YE, LIJUAN; STANFORD, REBECCA RONGRONG; ZHANG, DONGFANG; ZHANG, XINGSONG; WEI, WANLI

    2016-01-01

    The Xuanwei county in China has a high incidence of lung cancer and related mortality. Previous studies have suggested that these cases may be associated with a distinctive pattern of mutations in the epithelial growth factor receptor (EGFR) gene. In this retrospective study, we investigated the mutation profile of EGFR in non-small-cell lung cancer (NSCLC) tissues from patients in Xuanwei, and the associated clinicopathological characteristics. Specimens from 258 consecutive patients with lung cancer (90 from Xuanwei and 168 from other areas of Yunnan province) were subjected to amplification refractory mutation system-polymerase chain reaction (ARMS-PCR) to detect EGFR mutations. In 67 specimens from Xuanwei, the results were confirmed by direct DNA sequencing for EGFR mutations. Immunohistochemistry (IHC) for the echinoderm microtubule-associated protein-like 4-anaplastic lymphoma kinase (EML4-ALK) fusion protein was performed on all specimens from Xuanwei. We observed that Xuanwei patients presented with distinctive clinicopathological characteristics, including female gender predominance, younger age, higher rate of lymph node metastasis, higher rate of adenocarcinoma histological classification and lower disease stage, and a low rate of the ‘classical’ mutations on EGFR exons 19 and 21 compared with non-Xuanwei patients (7.8 and 21.6% vs. 49.3 and 39.7%, respectively; P<0.05 for combined data). However, a significantly higher percentage of Xuanwei patients harbored co-mutation of EGFR exons 18 and 20 compared with non-Xuanwei patients (45.1 vs. 4.1%, respectively; P<0.0001). Specimens from 2 Xuanwei patients (2.2%) were positive for the EML4-ALK fusion protein; by IHC, neither harbored EGFR mutations. There was no obvious association between EGFR mutations and disease stage or lymph node involvement. Thus, NSCLC patients in Xuanwei presented with a unique EGFR profile of high rates of co-mutation of exons 18 and 20, and low rates of exon 19 or 21

  1. Lung surgery

    MedlinePlus

    ... balloon-like tissues (blebs) that cause lung collapse ( pneumothorax ) Wedge resection, to remove part of a lobe ... Treat injuries that cause lung tissue to collapse ( pneumothorax or hemothorax ) Treat permanently collapsed lung tissue ( atelectasis ) ...

  2. Lung Diseases

    MedlinePlus

    ... many disorders affecting the lungs, such as asthma, COPD, infections like influenza, pneumonia and tuberculosis, lung cancer, and many other breathing problems. Some lung diseases can lead to respiratory failure. Dept. of Health and Human Services Office on Women's Health

  3. Lung disease

    MedlinePlus

    ... the lungs to take in oxygen and release carbon dioxide. People with this type of lung disorder often ... the lungs to take up oxygen and release carbon dioxide. These diseases may also affect heart function. An ...

  4. Pulmonary capillary wedge pressure, as inferred from lung areas in gated blood-pool scintigrams: concise communication

    SciTech Connect

    Urbina, A.; Okada, R.D.; Palacios, I.; Osbakken, M.; Strauss, H.W.

    1981-11-01

    To determine whether the apex-to-base distribution of pulmonary blood volume, as obtained from gated cardiac blood-pool scans, could be used as a noninvasive method to estimate mean pulmonary capillary wedge pressure (PCWP), gated blood-pool scans were analyzed in 77 patients who also had PCWP measurements at cardiac catheterization. Ten of these patients had gated cardiac blood-pool scans and PCWP measurements both at rest and during exercise. The apex-to-base distribution of pulmonary blood volume was determined from the end-systolic frame of the left anterior oblique view by placing equal-sized regions of interest over the apex and base of the right lung. The ratio of apex counts over base counts (A/B ratio) was considered abnormal if greater than unity. The mean A/B ratio was 1.15 +/- 0.27 (1 s.d.) for the 32 studies associated with an abnormal mean PCWP (greater than 12 mm Hg). The mean A/B ratio was 0.85 +/- 0.23 for the 55 studies associated with a normal mean PCWP (p less than 0.01 comparing normal group with abnormal). The sensitivity of the A/B ratio for a mean PCWP greater than 12 mm Hg was 81%R (26/32). The specificity of the A/B ratio for a mean PCWP greater than or equal to 12 mm Hg was 89% (49/55). Thus, noninvasive determination of the pulmonary apex-to-base ratio from gated cardiac blood-pool scans appears to differentiate subjects with normal and abnormal mean pulmonary capillary wedge pressures.

  5. Cracking in autoclaved aerated concrete: Experimental investigation and XFEM modeling

    SciTech Connect

    Ferretti, D.

    2015-01-15

    The paper aims to investigate and model cracking development in beams and deep-beams made of autoclaved aerated concrete (AAC). Fracture mechanics of AAC has been first studied by performing three-point bending tests on beams, similar to those commonly used for ordinary concrete elements. In some of these tests, crack growth has been also monitored by using ESPI laser technique. In this way, it has been possible to calibrate the main parameters of a proper cohesive law by means of extended finite element inverse analysis. Subsequently, cracking tests have been also performed on deep-beams, whose behavior is more representative of full scale walls. To validate the proposed cohesive law, deep-beam experimental behavior has been finally simulated through XFEM.

  6. Full-scale demonstration of improvement in aeration efficiency

    SciTech Connect

    Mueller, J.A.; Kim, Y.K.; Krupa, J.J.; Shkreli, F.; Nasr, S.; Fitzpatrick, B.

    2000-06-01

    This paper describes the results of side-by-side full-scale aeration testing of a plug-flow process and a modified contact stabilization process incorporating an anaerobic selector at the wastewater treatment facility in Fredonia, NY. Over 40 tests were completed utilizing the off-gas technique during the 2-month investigation period (summer of 1995). Compared to the plug-flow process, the modified contact stabilization process with internal sludge recycle was shown to have higher {alpha} values and to require less blower energy consumption when the selector operation was properly controlled. Dissolved oxygen concentration, selector COD concentration, and internal recycle sludge levels were found to be critical parameters in the successful operation of the modified process. Higher internal recycle sludge levels allowed the plant to run at more stable operating conditions in terms of the oxygen transfer efficiency, {alpha}, and sludge volume index.

  7. [Effects of substrate-aeration cultivation pattern on tomato growth].

    PubMed

    Zhao, Xu; Li, Tian-Lai; Sun, Zhou-Ping

    2010-01-01

    Aeroponics can increase the fruit yield of tomato plant, but its cost is very high. In this paper, tomato seedlings were planted with three cultures, i. e., whole perlite culture (CK), perlite-aeration culture (T1), and aeroponics (T2), and a comparative study was made on the seedlings growth. Compared with CK, T1 improved the gas environment in root zone significantly, with the CO2 and O2 concentrations in root zone being 0.2 and 1.17 times higher, and increased the plant height and stem diameter after 60 days of transplanting by 5.1% and 8.4%, respectively. The plant net photosynthetic rate of T1 was significantly higher than that of CK, with the maximum value after transplanting 45 days increased by 13%. T1 also increased the root activity and ion absorbing ability significantly, with the root activity after transplanting 45 days being 1.23 times of CK, and the root K, Ca, and Mg contents after transplanting 60 days increased by 31%, 37%, and 27%, respectively. The fruit yield of T1 was 1.16 times of CK. No significant differences in these indices were observed between T1 and T2, and less difference in the fruit soluble sugar and organic acid contents as well as the sugar-acid ratio was found among CK, T1, and T2. It was suggested that perlite-aeration cultivation pattern was an easy and feasible way to markedly improve the fruit yield of tomato plant. PMID:20387426

  8. Effects of loading rate and aeration on nitrogen removal and N2O emissions in intermittently aerated sequencing batch reactors treating slaughterhouse wastewater at 11 °C.

    PubMed

    Pan, Min; Hu, Zhenhu; Liu, Rui; Zhan, Xinmin

    2015-04-01

    This study aimed to find optimal operation conditions for nitrogen removal from high strength slaughterhouse wastewater at 11 °C using the intermittently aerated sequencing batch reactors (IASBRs) so as to provide an engineering control strategy for the IASBR technology. Two operational parameters were examined: (1) loading rates and (2) aeration rates. Both the two parameters affected variation of DO concentrations in the IASBR operation cycles. It was found that to achieve efficient nitrogen removal via partial nitrification-denitrification (PND), "DO elbow" point must appear at the end of the last aeration period. There was a correlation between the ammonium oxidizing bacteria (AOB)/nitrite oxidizing bacteria (NOB) ratio and the average DO concentrations in the last aeration periods; when the average DO concentrations in the last aeration periods were lower than 4.86 mg/L, AOB became the dominant nitrifier population, which benefited nitrogen removal via PND. Both the nitrogen loading rate and the aeration rate influenced the population sizes of AOB and NOB. To accomplish efficient nitrogen removal via PND, the optimum aeration rate (A, L air/min) applied can be predicted according to the average organic loading rates based on mathematical equations developed in this study. The research shows that the amount of N2O generation in the aeration period was reduced with increasing the aeration rate; however, the highest N2O generation in the non-aeration period was observed at the optimum aeration rates. PMID:25348656

  9. Magnetic resonance imaging studies of spontaneous capillary water imbibition in aerated gypsum

    NASA Astrophysics Data System (ADS)

    Song, Kyung-Min; Mitchell, Jonathan; Jaffel, Hamouda; Gladden, Lynn F.

    2011-03-01

    In this paper we investigate both capillary water imbibition and the sorptivity of aerated gypsum plaster, and how these sorption characteristics are related to the pore structure of the material. These characteristics are examined by monitoring mass change using the conventional gravimetric method and by obtaining water content profiles using non-destructive magnetic resonance imaging (MRI) techniques during capillary imbibition of water. Here, three different gypsum samples are investigated: one non-aerated reference gypsum sample and two aerated gypsum samples produced with different volumetric air fractions. The capillary water absorption into the reference sample follows t1/2 kinetics (Fickian diffusion), where t is the time of ingress. However, in the aerated gypsum samples there are deviations from t1/2 kinetics. The MRI results show unambiguously that two wetting fronts advance through the aerated structure; an observation that cannot be made from the gravimetric data alone. The water content profiles of the aerated gypsum samples are therefore analysed by treating them as the sum of two separate absorption processes using sharp front analysis. The capillary water absorption properties of this material are well described as a parallel combination of fast absorption into fine matrix pores and slow absorption into a modified structure of matrix pores inter-connected to air voids introduced into the slurry by aeration.

  10. The importance of aeration strategy in fuel alcohol fermentations contaminated with Dekkera/Brettanomyces yeasts.

    PubMed

    Abbott, D A; Ingledew, W M

    2005-11-01

    Whole corn mash fermentations infected with industrially-isolated Brettanomyces yeasts were not affected even when viable Brettanomyces yeasts out-numbered Saccharomyces yeasts tenfold at the onset of fermentation. Therefore, aeration, a parameter that is pivotal to the physiology of Dekkera/Brettanomyces yeasts, was investigated in mixed culture fermentations. Results suggest that aeration strategy plays a significant role in Dekkera/Brettanomyces-mediated inhibition of fuel alcohol fermentations. Although growth of Saccharomyces cerevisiae was not impeded, mixed culture fermentations aerated at rates of > or =20 ml air l(-1) mash min(-1) showed decreased ethanol yields and an accumulation of acetic acid. The importance of aeration was examined further in combination with organic acid(s). Growth of Saccharomyces occurred more rapidly than growth of Brettanomyces yeasts in all conditions. The combination of 0.075% (w/v) acetic acid and contamination with Brettanomyces TK 1404W did not negatively impact the final ethanol yield under fermentative conditions. Aeration, however, did prove to be detrimental to final ethanol yields. With the inclusion of aeration in the control condition (no organic acid stress) and in each fermentation containing organic acid(s), the final ethanol yields were decreased. It was therefore concluded that aeration strategy is the key parameter in regards to the negative effects observed in fuel alcohol fermentations infected with Dekkera/Brettanomyces yeasts. PMID:15782293

  11. Demonstration of membrane aeration panels, City of Geneva wastewater treatment plant. Final report

    SciTech Connect

    1995-01-01

    The report describes the design, construction, and testing of membrane aeration panels at the Marsh Creek wastewater treatment plant (WWTP) in Geneva, NY. The operators at the Geneva plant have undertaken a long-term program to upgrade wastewater treatment processes and lower operating costs. The aging mechanical surface aerators at the Marsh Creek treatment plant were replaced by a state-of-the-art membrane panel system. This fine-bubble diffused air system offers higher oxygen transfer efficiency than surface aerators or other types of fine-bubble diffused-air systems. The project had four objectives: to decrease the amount of electricity used at the plant for aeration; to enable the plant`s existing aeration basins to accommodate higher organic loads and/or nitrify the wastewater should the need arise; to provide an event distribution of dissolved oxygen within the aeration basins to enhance biological wastewater treatment activity; and to provide technical data to assess the performance of the membrane panel system versus other forms of wastewater aeration.

  12. Optimization of aeration for biodiesel production by Scenedesmus obliquus grown in municipal wastewater.

    PubMed

    Han, Song-Fang; Jin, Wenbiao; Tu, Renjie; Abomohra, Abd El-Fatah; Wang, Zhi-Han

    2016-07-01

    Despite the significant breakthroughs in research on microalgae as a feedstock for biodiesel, its production cost is still much higher than that of fossil diesel. One possible solution to overcome this problem is to optimize algal growth and lipid production in wastewater. The present study examines the optimization of pretreatment of municipal wastewater and aeration conditions in order to enhance the lipid productivity of Scenedesmus obliquus. Results showed that no significant differences were recorded in lipid productivity of S. obliquus grown in primary settled or sterilized municipal wastewater; however, ultrasound pretreatment of wastewater significantly decreased the lipid production. Whereas, aeration rates of 0.2 vvm significantly increased lipid content by 51 %, with respect to the non-aerated culture, which resulted in maximum lipid productivity (32.5 mg L(-1) day(-1)). Furthermore, aeration enrichment by 2 % CO2 resulted in increase of lipid productivity by 46 % over the CO2 non-enriched aerated culture. Fatty acid profile showed that optimized aeration significantly enhanced monounsaturated fatty acid production, composed mainly of C18:1, by 1.8 times over the non-aerated S. obliquus culture with insignificant changes in polyunsaturated fatty acid proportion; suggesting better biodiesel characteristics for the optimized culture. PMID:26969589

  13. Demonstration of membrane aeration panels: City of Geneva Wastewater Treatment Plant. Final report

    SciTech Connect

    1995-01-01

    This report describes the design, construction, and testing of membrane aeration panels at the Marsh Creek wastewater treatment plant (WWTP) in Geneva, NY. The operators at the Geneva plant have undertaken a long-term program to upgrade wastewater treatment processes and lower operating costs. The aging mechanical surface aerators at the Marsh Creek treatment plant were replaced by a state-of-the-art membrane panel system. This fine-bubble diffused air system offers higher oxygen transfer efficiency than surface aerators or other types of fine-bubble diffused-air systems. The project had four objectives: to decrease the amount of electricity used at the plant for aeration; to enable the plant`s existing aeration basins to accommodate higher organic loads and/or nitrify the wastewater should the need arise; to provide an even distribution of dissolved oxygen within the aeration basins to enhance biological wastewater treatment activity; and to provide technical data to assess the performance of the membrane panel system versus other forms of wastewater aeration.

  14. Effects of aeration and natural zeolite on ammonium removal during the treatment of sewage by mesocosm-scale constructed wetlands.

    PubMed

    Araya, F; Vera, I; Sáez, K; Vidal, G

    2016-01-01

    The objective was to evaluate the effects of intermittent artificial aeration cycles and natural zeolite as a support medium, in addition to the contribution of plants (Schoenoplectus californicus) on NH4(+)-N removal during sewage treatment by Constructed Wetlands (CW). Two lines of Mesocosm Constructed Wetland (MCW) were installed: (a) gravel line (i.e. G-Line) and (b) zeolite line (i.e. Z-Line). Aeration increased the NH4(+)-N removal efficiency by 20-45% in the G-Line. Natural zeolite increased the NH4(+)-N removal efficiency by up to 60% in the Z-Line. Plants contributed 15-30% of the NH4(+)-N removal efficiency and no difference between the G-Line and the Z-Line. Conversely, the NH4(+)-N removal rate was shown to only increase with the use of natural zeolite. However, the MCW with natural zeolite, the NH4(+)-N removal rate showed a direct relationship only with the NH4(+)-N influent concentration. Additionally, relationship between the oxygen, energy and area regarding the NH4(+)-N removal efficiency was established for 2.5-12.5 gO2/(kWh-m(2)) in the G-Line and 0.1-2.6 gO2/(kWh-m(2)) in the Z-Line. Finally, it was established that a combination of natural zeolite as a support medium and the aeration strategy in a single CW could regenerate the zeolite's adsorption sites and maintain a given NH4(+)-N removal efficiency over time. PMID:26848982

  15. Aeration of the teuftal landfill: Field scale concept and lab scale simulation.

    PubMed

    Ritzkowski, Marco; Walker, Beat; Kuchta, Kerstin; Raga, Roberto; Stegmann, Rainer

    2016-09-01

    Long lasting post-closure care (PCC) is often the major financial burden for operators of municipal solid waste (MSW) landfills. Beside costs for the installation and maintenance of technical equipment and barriers, in particular long term treatment of leachate and landfill gas has to be paid from capital surplus. Estimations based on laboratory experiments project time periods of many decades until leachate quality allows for direct discharge (i.e. no need for further purification). Projections based on leachate samples derived from the last 37years for 35 German landfills confirm these assumption. Moreover, the data illustrate that in particular ammonium nitrogen concentrations are likely to fall below limit values only after a period of 300years. In order to avoid long lasting PCC the operator of Teuftal landfill, located in the Swiss canton Bern, decided to biologically stabilize the landfill by means of a combined in situ aeration and moisturization approach. In December 2014 the aeration started at a landfill section containing approximately 30% of the total landfill volume. From summer 2016 onwards the remaining part of the landfill will be aerated. Landfill aeration through horizontal gas and leachate drains is carried out for the first time in field scale in Europe. The technical concept is described in the paper. Parallel to field scale aeration, investigations for the carbon and nitrogen turnover are carried out by means of both simulated aerated landfills and simulated anaerobic landfills. The results presented in this paper demonstrate that aeration is capable to enhance, both carbon mobilization and discharge via the gas phase. This effect comes along with a significant increase in bio-stabilization of the waste organic fraction, which positively affects the landfill emission behavior in the long run. In terms of leachate pollution reduction it could be demonstrated that the organic load decrease fast and widely independent of the adjusted aeration

  16. Epidemiology of Lung Cancer.

    PubMed

    Schwartz, Ann G; Cote, Michele L

    2016-01-01

    Lung cancer continues to be one of the most common causes of cancer death despite understanding the major cause of the disease: cigarette smoking. Smoking increases lung cancer risk 5- to 10-fold with a clear dose-response relationship. Exposure to environmental tobacco smoke among nonsmokers increases lung cancer risk about 20%. Risks for marijuana and hookah use, and the new e-cigarettes, are yet to be consistently defined and will be important areas for continued research as use of these products increases. Other known environmental risk factors include exposures to radon, asbestos, diesel, and ionizing radiation. Host factors have also been associated with lung cancer risk, including family history of lung cancer, history of chronic obstructive pulmonary disease and infections. Studies to identify genes associated with lung cancer susceptibility have consistently identified chromosomal regions on 15q25, 6p21 and 5p15 associated with lung cancer risk. Risk prediction models for lung cancer typically include age, sex, cigarette smoking intensity and/or duration, medical history, and occupational exposures, however there is not yet a risk prediction model currently recommended for general use. As lung cancer screening becomes more widespread, a validated model will be needed to better define risk groups to inform screening guidelines. PMID:26667337

  17. Lung cancer

    PubMed Central

    Dong, Jie; Kislinger, Thomas; Jurisica, Igor; Wigle, Dennis A.

    2010-01-01

    High-throughput genomic data for both lung development and lung cancer continue to accumulate. Significant molecular intersection between these two processes has been hypothesized due to overlap in phenotypes and genomic variation. Examining the network biology of both cancer and development of the lung may shed functional light on the individual signaling modules involved. Stem cell biology may explain a portion of this network intersection and consequently studying lung organogenesis may have relevance for understanding lung cancer. This review summarizes our understanding of the potential overlapping mechanisms involved in lung development and lung tumorigenesis. PMID:19202349

  18. The effectiveness of circulating aeration in air and high purity oxygen systems for control of VOC emissions from aeration basins

    SciTech Connect

    Zhu, H.; Keener, T.C.; Bishop, P.L.; Orton, T.L.; Wang, M.; Siddiqui, K.F.

    1997-12-31

    A simple steady state circulating aeration system (CAS) model has been used to study the effects of volatility and degradability on the fate of VOCs in both air and high purity oxygen (HPO) systems. With increase of circulation ratio in an air CAS, air emissions by stripping can be significantly reduced for compounds of low degradabilities and high volatilities. Enhancement of biodegradation is more significant for compounds of high degradabilities and volatilities. A large portion of VOCs will remain in the wastewater when circulation ratio is high, especially for VOCs that are difficult to degrade. In HPO systems, emissions by stripping are much less than air systems. However, VOCs will remain in the wastewater if they have poor degradabilities. Volatilities of VOCs are not important in HPO systems. Due to their wide range and large uncertainties, degradation rate constants are a major factor determining the effectiveness of a CAS for VOC emission control

  19. Aeration remediation of a polluted waterway increases near-surface coarse and culturable microbial aerosols.

    PubMed

    Dueker, M Elias; O'Mullan, Gregory D

    2014-04-15

    Aeration remediation is currently used in polluted urban waterways to increase oxygen levels in the water column. Recent studies have provided increasing evidence that the bursting of bubbles at water surfaces introduced by aeration, or other surface disturbances, can transfer viable bacteria to the air. In heavily sewage-polluted waterways these water-originated bacterial aerosols may pose as a health risk to recreators in small boats or residents inhabiting the shoreline. Nonetheless, few studies have explored aerosols above active aeration remediation projects in waterways or investigated how bacterial aerosols change with vertical distance from aeration activities. This study, conducted at the Newtown Creek superfund site in Brooklyn, NY, USA, measured coarse aerosol particles and culturable bacteria in near-surface air above waters undergoing aeration remediation. Regardless of aeration operation culturable bacterial fallout was greater near-surface (0.6m above water) than previously-reported measurements made at 2.5m. Molecular analysis of the 16S rRNA gene sequences from isolated bacteria demonstrates that water and air shared a large number of bacterial genera and that the genera present in the near-surface aerosols (0.6m) contained water-associated Vibrio and Caulobacter, which were not present at 2.5m, despite the smaller sequence library size from the near-surface. Also, the near-surface microbial assemblage had significantly greater association with sequences detected previously in aquatic environments compared to the 2.5m library. We found compelling evidence that aeration activity contributed to this vertical gradient in bacterial aerosol concentrations and identity. Similar to results from 2.5m, concentrations of near-surface respirable coarse aerosols (<10 um) increased significantly when aeration was occurring. Culturable bacterial aerosol fallout was also greater near-surface when the aerator was on compared to simultaneous measurements made at 2

  20. Numerical modelling of the strength of highly porous aerated autoclaved concrete

    SciTech Connect

    Schenider, T.; Greil, P.; Schober, G.

    1998-12-31

    Highly porous building materials like aerated autoclaved concrete are characterized by low thermal conductivity and high mechanical strength, which both strongly depend on porosity. The influence of porosity distribution on the compressive strength of aerated autoclaved concrete was investigated by using finite element analysis and multiaxial Weibull theory. Calculations of failure probability of microstructures with ordered as well as random pore configurations show a dependence of compressive strength on the Weibull modulus of the matrix material and the size and arrangement of pores. The results of the calculations are compared to experimental data of aerated autoclaved concrete.

  1. Improving microalgal growth with reduced diameters of aeration bubbles and enhanced mass transfer of solution in an oscillating flow field.

    PubMed

    Yang, Zongbo; Cheng, Jun; Lin, Richen; Zhou, Junhu; Cen, Kefa

    2016-07-01

    A novel oscillating gas aerator combined with an oscillating baffle was proposed to generate smaller aeration bubbles and enhance solution mass transfer, which can improve microalgal growth in a raceway pond. A high-speed photography system (HSP) was used to measure bubble diameter and generation time, and online precise dissolved oxygen probes and pH probes were used to measure mass-transfer coefficient and mixing time. Bubble diameter and generation time decreased with decreased aeration gas rate, decreased orifice diameter, and increased water velocity in the oscillating gas aerator. The optimized oscillating gas aerator decreased bubble diameter and generation time by 25% and 58%, respectively, compared with a horizontal tubular gas aerator. Using an oscillating gas aerator and an oscillating baffle in a raceway pond increased the solution mass-transfer coefficient by 15% and decreased mixing time by 32%; consequently, microalgal biomass yield increased by 19%. PMID:27035474

  2. On freeze-thaw sequence of vital organ of assuming the cryoablation for malignant lung tumors by using cryoprobe as heat source.

    PubMed

    Nakatsuka, Seishi; Yashiro, Hideki; Inoue, Masanori; Kuribayashi, Sachio; Kawamura, Masafumi; Izumi, Yotaro; Tsukada, Norimasa; Yamauchi, Yoshikane; Hashimoto, Kohei; Iwata, Kansei; Nagasawa, Taisuke; Lin, Yi-Shan

    2010-12-01

    Regarding cryoablation for the malignant lung tumors, multiple trials of the freeze-thaw process have been made, and we considered it necessary to view and analyze the freeze-thaw process as a freeze-thaw sequence. We caused the sequence in a porcine lung in vivo by using an acicular, cylindrical stainless-steel probe as the heat source for the freeze-thaw sequence and cooling to -150 °C with super high-pressure argon gas by causing the Joule-Thomson effect phenomenon at the tip of the probe. In this experiment, we examined the sequence by measuring the temperature and using the isothermal curve and the freezing function. As a result, it was demonstrated that the freezing characteristics considerably differed in the first sequence and the second sequence from those of non-aerated organs such as liver and kidney. In our experiments on porcine lung, thermal properties were considered to change as the bleeding caused by the first thawing infiltrated in the lung parenchyma, and it was confirmed that the frozen area in the second cycle was dramatically enlarged as compared with the first cycle (when a similar sequence is continuously repeated, we say it as cycle). This paper provides these details. PMID:21036162

  3. Measurement of Black Carbon, Particle Number and Mass, and Lung-Deposited Surface Area Emission Factors from in-Use Locomotive

    NASA Astrophysics Data System (ADS)

    Ban-Weiss, G. A.; Krasowsky, T.; Sioutas, C.; Daher, N.

    2014-12-01

    As pollutant emissions from motor vehicles have vastly decreased over the last decades, the relative contribution from non-road sources has increased. There is a serious lack of real-world emissions measurements for many non-road sources including locomotives. As such, uncertainties in emissions from these sources is high. Locomotives contribute to human exposure of diesel pollutants near ports, railyards, and rail lines. Reducing uncertainty in current estimates of locomotive emissions is needed for enhancing the accuracy of emission inventories with corresponding improvements in health risk, air pollution, and climate assessments. Particulate matter emissions from a large sample (N=88) of in-use freight locomotives were measured in the Alameda Corridor, located near the port of Los Angeles. Emission factors for black carbon (BC), particle number (PN), fine particulate mass (PM2.5), and lung-deposited surface area (LDSA) were computed based on 1 Hz measurements of the rise and fall of particulate emissions and CO2 concentrations as the locomotives passed the sampling location. Mean emission factors ± standard deviations were 0.9 ± 0.5 g kg-1 of fuel consumed for BC, (2.1 ± 1.5)x1016 # kg-1 for PN, 1.6 ± 1.3 g kg-1 for PM2.5, and (2.2 ± 1.7)x1013 μm2 kg-1 for LDSA. Emission factors for individual trains were slightly skewed, with the dirtiest 10% of locomotives responsible for 20%, 24%, 28%, and 27% of total BC, PN, PM2.5, and LDSA emissions, respectively. BC versus LDSA emissions from individual locomotives were found to be anti-correlated, suggesting that the highest emitters of black carbon may in fact result in less particle lung-deposited surface area than lower BC emitters. Using results presented here along with previous measurements, we compare for freight trains versus diesel trucks the amount of BC emissions associated with pulling an intermodal freight container over a given distance. Emission factors for locomotives presented here establish a

  4. Rapid Startup and Loading of an Attached Growth, Simultaneous Nitrification/Denitrification Membrane Aerated Bioreactor

    NASA Technical Reports Server (NTRS)

    Meyer, Caitlin; Vega, Leticia

    2014-01-01

    The Membrane Aerated Bioreactor (MABR) is an attached-growth biological system for simultaneous nitrification and denitrification. This design is an innovative approach to common terrestrial wastewater treatments for nitrogen and carbon removal. Implementing a biologically-based water treatment system for long-duration human exploration is an attractive, low energy alternative to physiochemical processes. Two obstacles to implementing such a system are (1) the "start-up" duration from inoculation to steady-state operations and (2) the amount of surface area needed for the biological activity to occur. The Advanced Water Recovery Systems (AWRS) team at JSC explored these two issues through two tests; a rapid inoculation study and a wastewater loading study. Results from these tests demonstrate that the duration from inoculation to steady state can be reduced to two weeks and that the surface area to volume ratio baseline used in the Alternative Water Processor (AWP) test was higher than what was needed to remove the organic carbon and ammonium from the system.

  5. Micro-aeration for hydrogen sulfide removal from biogas

    NASA Astrophysics Data System (ADS)

    Duangmanee, Thanapong

    The presence of sulfur compounds (e.g. protein, sulfate, thiosulfate, sulfite, etc.) in the feed stream generates highly corrosive and odorous hydrogen sulfide during anaerobic digestion. The high sulfide level in the biogas stream is not only poisonous to many novel metal catalysts employed in thermo-catalytic processes but also reduces the quality of methane to produce renewable energy. This study used an innovative, low-maintenance, low-cost biological sulfide removal technology to remove sulfides simultaneously from both gas and liquid phase. ORP (Oxidation-Reduction-Potential) was used as the controlling parameter to precisely regulate air injection to the sulfide oxidizing unit (SOU). The microaeration technique provided just enough oxygen to partially oxidize sulfides to elemental sulfur without inhibiting methanogenesis. The SOU was equipped with a diffuser at the bottom for the dispersion of sulfide-laden biogas and injected air throughout the column. The SOU can be operated as a standalone unit or coupled with an anaerobic digester to simultaneously remove sulfide from the biogas and effluent. The integrated system was capable of reducing hydrogen sulfide in biogas from 2,450 to less than 2 ppmV with minimal sulfate production at the highest available sulfide loading rate of 0.24 kg/m3-day. More than 98% of sulfide removed was recovered as elemental sulfur. However, the standalone SOU was able to operate at high hydrogen sulfide loading of 1.46 kg/m 3-day at inlet sulfide concentration of 3000 ppmV and reduce the off-gas hydrogen sulfide concentrations to less than 10 ppmV. The experiment also revealed that the ORP controlled aeration was sensitive enough to prevent oxygen overdosing (dampening effect) during unexpected surges of aeration. Using generalized linear regression, a model predicting output H2S concentration based on input H2S concentrations, SOU medium heights, and biogas flow rates, was derived. With 95% confidence, output H2S concentration

  6. Improving microalgal growth with small bubbles in a raceway pond with swing gas aerators.

    PubMed

    Yang, Zongbo; Cheng, Jun; Liu, Jianzhong; Zhou, Junhu; Cen, Kefa

    2016-09-01

    A novel swing gas aerator was developed to generate small bubbles for improving the mass transfer coefficient and microalgal growth rate in a raceway pond. A high-speed photography system (HSP) was used to measure the bubble diameter and generation time, and online precise dissolved oxygen probes and pH probes were used to measure the mass transfer coefficient and mixing time. Bubble generation time and diameter decreased by 21% and 9%, respectively, when rubber gas aerators were swung in the microalgae solution. When water pump power and gas aeration rate increased in a raceway pond with swing gas aerators and oscillating baffles (SGAOB), bubble generation time and diameter decreased but solution velocity and mass transfer coefficient increased. The mass transfer coefficient increased by 25% and the solution velocity increased by 11% when SGAOB was used, and the microalgal biomass yield increased by 18%. PMID:27243604

  7. Improved design and optimization of aeration control for WWTPs by dynamic simulation.

    PubMed

    Alex, J; To, T Binh; Hartwig, P

    2002-01-01

    This paper introduces a model library based on the simulation environment MATLAB/SIMULINK which allows the simulation of the aeration system of an wastewater treatment plant (WWTP). The model library presented covers all parts of an aeration system starting with the compressor set over the common air rail, flow resistances through pipes, controllable valves, aeration membranes and ending last not least with the controllers involved. The main objective of the development of the simulation system is the design, test and the support of the installation of more predictable and efficient control concepts for the aeration system in WWTPs. An example is given to demonstrate the application of the simulation system and to promote a control scheme with a flexible reference value for the pressure at the common air rail based on a most open valve (MOV) concept. PMID:11936654

  8. Survival of Salmonella enterica in Aerated and Nonaerated Wastewaters from Dairy Lagoons

    PubMed Central

    Ravva, Subbarao V.; Sarreal, Chester Z.

    2014-01-01

    Salmonella is the most commonly identified foodborne pathogen in produce, meat and poultry. Cattle are known reservoirs of Salmonella and the pathogen excreted in feces ends up in manure flush lagoons. Salmonella enterica survival was monitored in wastewater from on-site holding lagoons equipped or not with circulating aerators at two dairies. All strains had poor survival rates and none proliferated in waters from aerated or settling lagoons. Populations of all three Salmonella serovars declined rapidly with decimal reduction times (D) of <2 days in aerated microcosms prepared from lagoon equipped with circulators. Populations of Salmonella decreased significantly in aerated microcosms (D = 4.2 d) compared to nonaerated waters (D = 7.4 d) and in summer (D = 3.4 d) compared to winter (D = 9.0 d). We propose holding the wastewater for sufficient decimal reduction cycles in lagoons to yield pathogen-free nutrient-rich water for crop irrigations and fertilization. PMID:25358096

  9. A new method of securing the airway for differential lung ventilation in intensive care.

    PubMed

    Skjeflo, G W; Dybwik, K

    2014-04-01

    Differential lung ventilation to achieve optimised ventilation for each lung is a procedure rarely used in the intensive care unit, to treat select cases of severe unilateral lung disease in intensive care. However, existing techniques both for securing the airway and ventilating the lungs are challenging and have complications. We present the use of differential lung ventilation in the intensive care setting, securing the airway with a technique not previously described, using endotracheal tubes inserted through a tracheotomy and orally. In the course of 1 month, we treated three patients with unilateral atelectatic and consolidated lungs by differential lung ventilation. The left lung was ventilated through an endotracheal tube inserted into the left main stem bronchus through a tracheotomy. The right lung was ventilated through an endotracheal tube with the cuff positioned immediately under the vocal cord. In patient 1, the diseased lung remained consolidated after 24 h of differential lung ventilation. In the two other patients, the diseased lungs responded to differential lung ventilation by increased compliance and radiographic increased aeration. Differential ventilation of the lungs with this novel technique is feasible and may increase the likelihood of successful treatment of atelectatic lungs refractory to conventional ventilator strategies. PMID:24588330

  10. Update in Lung Cancer 2014.

    PubMed

    Spira, Avrum; Halmos, Balazs; Powell, Charles A

    2015-08-01

    In the past 2 years, lung cancer research and clinical care have advanced significantly. Advancements in the field have improved outcomes and promise to lead to further reductions in deaths from lung cancer, the leading cause of cancer death worldwide. These advances include identification of new molecular targets for personalized targeted therapy, validation of molecular signatures of lung cancer risk in smokers, progress in lung tumor immunotherapy, and implementation of population-based lung cancer screening with chest computed tomography in the United States. In this review, we highlight recent research in these areas and challenges for the future. PMID:26230235

  11. Nitrate-removal activity of a biofilm attached to a perlite carrier under continuous aeration conditions.

    PubMed

    Yamashita, Takahiro; Yokoyama, Hiroshi; Kanafusa, Sumiyo; Ogino, Akifumi; Ishida, Mitsuyoshi; Osada, Takashi; Tanaka, Yasuo

    2011-01-01

    The nitrate-removal activity of a biofilm attached to a perlite carrier from an aerobic bioreactor used for treating dairy farm wastewater was examined by batch experiments under continuous aeration conditions. Despite aeration, the biofilm removed nitrate at a rate of 114.4 mg-N/kg-perlite/h from wastewater containing cow milk and manure. In a clone library analysis of the biofilm, bacteria showing high similarity to the denitrifying bacteria Thauera spp. were detected. PMID:21389601

  12. Bioreactor tests preliminary to landfill in situ aeration: a case study.

    PubMed

    Raga, Roberto; Cossu, Raffaello

    2013-04-01

    Lab scale tests in bioreactor were carried out in the framework of the characterization studies of a landfill where in situ aeration (possibly followed by landfill mining) had been proposed as part of the novel waste management strategy in a region in northern Italy. The tests were run to monitor the effects produced by aerobic conditions at different temperatures on waste sampled at different depths in the landfill, with focus on the carbon and nitrogen conversion during aeration. Temperatures ranging from 35 to 45°C were chosen, in order to evaluate possible inhibition of biodegradation processes (namely nitrification) at 45°C in the landfill. The results obtained showed positive effects of the aeration on leachate quality and a significant reduction of waste biodegradability. Although a delay of biodegradation processes was observed in the reactor run at 45°C, biodegradation rates increased after 2 months of aeration, providing very low values of the relevant parameters (as in the other aerated reactors) by the end of the study. Mass balances were carried out for TOC and NNH4(+); the findings obtained were encouraging and provided evidence of the effectiveness of carbon and nitrogen conversion processes in the aerated landfill simulation reactors. PMID:23274082

  13. Effect of the aeration system on the levels of airborne microorganisms generated at wastewater treatment plants.

    PubMed

    Sánchez-Monedero, M A; Aguilar, M I; Fenoll, R; Roig, A

    2008-08-01

    Six different wastewater treatment plants were monitored in order to identify the main bioaerosol sources and to evaluate the effect of the aeration system used in the biological treatment (air diffusion, horizontal rotors and surface turbine aerators) on the airborne microorganism levels to which workers may be exposed. Air samples were collected by using a single stage impactor. Total count of mesophilic bacteria was used as the monitoring parameter to compare the impact of the aeration system on generic bacterial bioaerosols rather than a quantitative estimation for pathogens or fecal indicator microbes. In this study, pre-treatment, biological treatment and sludge thickening were the processes that generated the highest amount of bioaerosols. Aeration systems involving mechanical agitation of the wastewater, such as horizontal rotors and surface turbines, generated a larger amount of bioaerosols (between 450 and 4580CFU/m(3)) than air diffuser aerators (between 22 and 57CFU/m(3)). The levels of airborne bacteria generated by air diffusers were very similar to those registered at the background locations (lower than 50CFU/m(3)), unaffected by the activities taking place in the wastewater treatment plant. The use of air diffusers as an aeration system for the biological treatment would significantly minimise the potential biological hazard that wastewater treatment plant workers may be exposed to. PMID:18662822

  14. Aeration effect on Spirulina platensis growth and γ-Linolenic acid production

    PubMed Central

    Ronda, Srinivasa Reddy; Bokka, Chandra Sekhar; Ketineni, Chandrika; Rijal, Binod; Allu, Prasada Rao

    2012-01-01

    The influence of aeration on algal growth and gamma-linolenic acid (GLA) production in a bubble column photobioreactor was investigated. Studies were performed in a 20-L reactor at different aeration rates (0.2– 2.5 vvm). Static, continuous, and periodic operation of air resulted in 41.9%, 88.4%, and 108% air saturation of dissolved oxygen, for which the corresponding values of GLA were 2.3, 6.5, and 7.5 mg·g-1 dry cell weight, respectively. An increase in the aeration rate from 0.2 to 2.5 vvm enhanced both the specific growth rate and GLA content under periodic sparging in the bicarbonate medium. With a 6-fold increase in the aeration rate, the GLA content of the alga increased by 69.64% (5.6–9.5 mg· g-1 dry cell weight). In addition, the total fatty acid (TFA) content in dry biomass increased from 2.22% to 4.41%, whereas the algae maintained a constant GLA to TFA ratio within the aeration rate tested. The dependence of GLA production on the aeration rate was explained by interrelating the GLA production rate with the specific growth rate using the Luedeking and Piret mixed growth model. PMID:24031799

  15. Generating CO{sub 2}-credits through landfill in situ aeration

    SciTech Connect

    Ritzkowski, M.; Stegmann, R.

    2010-04-15

    Landfills are some of the major anthropogenic sources of methane emissions worldwide. The installation and operation of gas extraction systems for many landfills in Europe and the US, often including technical installations for energy recovery, significantly reduced these emissions during the last decades. Residual landfill gas, however, is still continuously produced after the energy recovery became economically unattractive, thus resulting in ongoing methane emissions for many years. By landfill in situ aeration these methane emissions can be widely avoided both, during the aeration process as well as in the subsequent aftercare period. Based on model calculations and online monitoring data the amount of avoided CO{sub 2-eq}. can be determined. For an in situ aerated landfill in northern Germany, acting as a case study, 83-95% (depending on the kind and quality of top cover) of the greenhouse gas emission potential could be reduced under strictly controlled conditions. Recently the United Nations Framework Convention on Climate Change (UNFCCC) has approved a new methodology on the 'Avoidance of landfill gas emissions by in situ aeration of landfills' (). Based on this methodology landfill aeration projects might be considered for generation of Certified Emission Reductions (CERs) in the course of CDM projects. This paper contributes towards an evaluation of the potential of landfill aeration for methane emissions reduction.

  16. Improving arachidonic acid fermentation by Mortierella alpina through multistage temperature and aeration rate control in bioreactor.

    PubMed

    Gao, Min-Jie; Wang, Cheng; Zheng, Zhi-Yong; Zhu, Li; Zhan, Xiao-Bei; Lin, Chi-Chung

    2016-05-18

    Effective production of arachidonic acid (ARA) using Mortierella alpina was conducted in a 30-L airlift bioreactor. Varying the aeration rate and temperature significantly influenced cell morphology, cell growth, and ARA production, while the optimal aeration rate and temperature for cell growth and product formation were quite different. As a result, a two-stage aeration rate control strategy was constructed based on monitoring of cell morphology and ARA production under various aeration rate control levels (0.6-1.8 vvm). Using this strategy, ARA yield reached 4.7 g/L, an increase of 38.2% compared with the control (constant aeration rate control at 1.0 vvm). Dynamic temperature-control strategy was implemented based on the fermentation performance at various temperatures (13-28°C), with ARA level in total cellular lipid increased by 37.1% comparing to a constant-temperature control (25°C). On that basis, the combinatorial fermentation strategy of two-stage aeration rate control and dynamic temperature control was applied and ARA production achieved the highest level of 5.8 g/L. PMID:26038800

  17. Ecophysiology of wetland plant roots: A modelling comparison of aeration in relation to species distribution

    USGS Publications Warehouse

    Sorrell, B.K.; Mendelssohn, I.A.; McKee, K.L.; Woods, R.A.

    2000-01-01

    This study examined the potential for inter-specific differences in root aeration to determine wetland plant distribution in nature. We compared aeration in species that differ in the type of sediment and depth of water they colonize. Differences in root anatomy, structure and physiology were applied to aeration models that predicted the maximum possible aerobic lengths and development of anoxic zones in primary adventitious roots. Differences in anatomy and metabolism that provided higher axial fluxes of oxygen allowed deeper root growth in species that favour more reducing sediments and deeper water. Modelling identified factors that affected growth in anoxic soils through their effects on aeration. These included lateral root formation, which occurred at the expense of extension of the primary root because of the additional respiratory demand they imposed, reducing oxygen fluxes to the tip and stele, and the development of stelar anoxia. However, changes in sediment oxygen demand had little detectable effect on aeration in the primary roots due to their low wall permeability and high surface impedance, but appeared to reduce internal oxygen availability by accelerating loss from laterals. The development of pressurized convective gas flow in shoots and rhizomes was also found to be important in assisting root aeration, as it maintained higher basal oxygen concentrations at the rhizome-root junctions in species growing into deep water. (C) 2000 Annals of Botany Company.

  18. Laboratory study of nitrification, denitrification and anammox processes in membrane bioreactors considering periodic aeration.

    PubMed

    Abbassi, Rouzbeh; Yadav, Asheesh Kumar; Huang, Shan; Jaffé, Peter R

    2014-09-01

    The possibility of using membrane bioreactors (MBRs) in simultaneous nitrification-anammox-denitrification (SNAD) by considering periodic aeration cycles was investigated. Two separate reactors were operated to investigate the effect of different anammox biomass in the presence of nitrifying and denitrifying biomass on the final nitrogen removal efficiency. The results illustrated that the reactor with higher anammox biomass was more robust to oxygen cycling. Around 98% Total Nitrogen (TN) and 83% Total Organic Carbon (TOC) removal efficiencies were observed by applying one hour aeration over a four-hour cycle. Decreasing the aeration time to 30, 15, and 2 min during a four-hour cycle affected the final TN removal efficiencies. However, the effect of decreasing aeration on the TN removal efficiencies in the reactor with higher anammox biomass was much lower compared to the regular reactor. The nitrous oxide (N2O) emission was a function of aeration as well, and was lower in the reactor with higher anammox biomass. The results of q-PCR analysis confirmed the simultaneous co-existence of nitrifiers, anammox, and denitrifiers in both of the reactors. To simulate the TN removal in these reactors as a function of the aeration time, a new model, based on first order reaction kinetics for both denitrification and anammox was developed and yielded a good agreement with the experimental observations. PMID:24814548

  19. Photosynthetic aeration in biological wastewater treatment using immobilized microalgae-bacteria symbiosis.

    PubMed

    Praveen, Prashant; Loh, Kai-Chee

    2015-12-01

    Chlorella vulgaris encapsulated in alginate beads were added into a bioreactor treating synthetic wastewater using Pseudomonas putida. A symbiotic CO2/O2 gas exchange was established between the two microorganisms for photosynthetic aeration of wastewater. During batch operation, glucose removal efficiency in the bioreactor improved from 50% in 12 h without aeration to 100% in 6 h, when the bioreactor was aerated photosynthetically. During continuous operation, the bioreactor was operated at a low hydraulic retention time of 3.3 h at feed concentrations of 250 and 500 mg/L glucose. The removal efficiency at 500 mg/L increased from 73% without aeration to 100% in the presence of immobilized microalgae. The initial microalgae concentration was critical to achieve adequate aeration, and the removal rate increased with increasing microalgae concentration. The highest removal rate of 142 mg/L-h glucose was achieved at an initial microalgae concentration of 190 mg/L. Quantification of microalgae growth in the alginate beads indicated an exponential growth during symbiosis, indicating that the bioreactor performance was limited by oxygen production rates. Under symbiotic conditions, the chlorophyll content of the immobilized microalgae increased by more than 30%. These results indicate that immobilized microalgae in symbiosis with heterotrophic bacteria are promising in wastewater aeration. PMID:26266755

  20. Stratification structure of polysaccharides and proteins in activated sludge with different aeration in membrane bioreactor.

    PubMed

    Zhang, Haifeng; Yu, Haihuan; Zhang, Lanhe; Song, Lianfa

    2015-09-01

    The effect of distribution pattern of polysaccharides (PS) and proteins (PN) in activated sludge (AS) stratification with different aeration rates on membrane fouling and rejection efficiency were investigated. During high aeration, PN and PS concentrations increased in supernatant, the dominant fraction (84% of PN and 73% of PS) was small molecules (<1 kDa). Less slime and loose bound extracellular polymeric substances (LB-EPS), more tight bound EPS (TB-EPS) were observed compared with low aeration. The decrease in PN/PS ratio and Ca(2+) concentration within EPS deteriorated AS flocculation ability. At slow trans-membrane pressure (TMP) rise stage, fouling rate under high aeration was 41% lower than low aeration due to lower PN within EPS outer. Low PS rejection rate (about 23%) leaded to higher PS in effluent at this stage. High PS rejection rate (about 94%) at rapid TMP rise stage resulted in about 2.2-time higher fouling rate than that low aeration. PMID:26056777

  1. Nitrogen removal in intermittently aerated biofilm airlift reactor

    SciTech Connect

    Benthum, W.A.J. van; Mathijssen, J.P.M.; Sunde, J.; Loosdrecht, M.C.M. van; Heijnen, J.J.; Garrido, J.M.

    1998-03-01

    Nitrogen compounds like ammonium, nitrite, and nitrate can be found in domestic as well as industrial wastewaters. These compounds can cause many environmental problems in surface waters but can be removed by applying nitrification and denitrification processes. Denitrification was integrated in a nitrifying biofilm airlift suspension reactor by intermittent aeration. A total nitrogen-removal efficiency of 75% was reached at an aerobic ammonia load of 5 kg{sub N}{center_dot}m{sup {minus}3}{center_dot}d{sup {minus}1}. Acetate was added to the reactor during the anoxic periods. The system was operated at sufficiently long anoxic hydraulic retention times to allow suspended growth of denitrifying heterotrophs. However, the heterotrophic biomass did not grow in suspension but grew as protuberances and layers on the nitrifying biofilms. Nitrification and denitrification occurred via nitrite as an intermediate, possibly because denitrifiers outcompeted the nitrite oxidizers. Because of the establishing of the nitrite route, a low average COD/N ratio of 2.6 kg{sub COD}{center_dot}kg{sub N}{sup {minus}1} was obtained. When denitrifying operation with acetate addition was started, initially almost all nitrogen removed was emitted as nitrous oxide. Subsequently, the nitrous oxide emission strongly decreased to almost zero in a period of 30 days, while the nitrogen-removal efficiency was maintained.

  2. Atrazine removal from aqueous solutions using submerged biological aerated filter

    PubMed Central

    2013-01-01

    Atrazine is widely used in the agriculture as an herbicide. Due to its high mobility, Atrazine leaks into the groundwaters, surface waters, and drinking water wells. Many physical and chemical methods have been suggested for removing Atrazine from aquatic environments. However, these methods are very costly, have many performance problems, produce a lot of toxic intermediates which are very harmful and dangerous, and cannot completely mineralize Atrazine. In this study, biodegradation of Atrazine by microbial consortium was evaluated in the aquatic environment. In order to assess the Atrazine removal from the aquatic environment, submerged biological aerated filter (SBAF) was fed with synthetic wastewater based on sucrose and Atrazine at different hydraulic retention times (HRTs). The maximum efficiencies for Atrazine and Soluble Chemical Oxygen Demand (SCOD) removal were 97.9% and 98.9%, respectively. The study findings showed that Stover-Kincannon model had very good fitness (R2 > 99%) in loading Atrazine in the biofilter and by increasing the initial concentration of Atrazine, the removal efficiency increased. Aerobic mixed biofilm culture was observed to be suitable for the treatment of Atrazine from aquatic environment. There was no significant inhibition effect on mixed aerobic microbial consortia. Atrazine degradation depended on the strength of wastewater and the amount of Atrazine in the influent. PMID:24499572

  3. Removal of pharmaceuticals in aerated biofilters with manganese feeding.

    PubMed

    Zhang, Yongjun; Zhu, Hong; Szewzyk, Ulrich; Geissen, Sven Uwe

    2015-04-01

    A tertiary treatment step is required in current wastewater treatment plants to remove trace pollutants and thus to prevent their extensive occurrence in the aquatic environment. In this study, natural MnOx ore and natural zeolite were separately used to pack two lab-scale aerated biofilters, which were operated in approximately 1.5 years for the removal of frequently occurring pharmaceuticals, including carbamazepine (CBZ), diclofenac (DFC), and sulfamethoxazole (SMX), out of synthetic and real secondary effluents. Mn(2+) was added in the feeds to promote the growth of iron/manganese oxidizing bacteria which were recently found to be capable of degrading recalcitrant pollutants. An effective removal (80-90%) of DFC and SMX was observed in both biofilters after adaptation while a significant removal of CBZ was not found. Both biofilters also achieved an effective removal of spiked Mn(2+), but a limited removal of carbon and nitrogen contents. Additionally, MnOx biofilter removed 50% of UV254 from real secondary effluent, indicating a high potential on the removal of aromatic compounds. PMID:25638775

  4. Fine-pore aeration diffusers: accelerated membrane ageing studies.

    PubMed

    Kaliman, An; Rosso, Diego; Leu, Shao-Yuan; Stenstrom, Michael K

    2008-01-01

    Polymeric membranes are widely used in aeration systems for biological treatment. These membranes may degrade over time and are sensitive to fouling and scaling. Membrane degradation is reflected in a decline in operating performance and higher headloss, resulting in increased energy costs. Mechanical property parameters, such as membrane hardness, Young's modulus, and orifice creep, were used to characterize the performance of membranes over time in operation and to predict their failure. Used diffusers from municipal wastewater treatment plants were collected and tested for efficiency and headloss, and then dissected to facilitate measurements of Young's modulus, hardness, and orifice creep. Higher degree of membrane fouling corresponded consistently with larger orifice creep. A lab-scale membrane ageing simulation was performed with polyurethane and four different ethylene-propylene-diene (EPDM) membrane diffusers by subjecting them to chemical ageing cycles and periodic testing. The results confirmed full-scale plant results and showed the superiority of orifice creep over Young's modulus and hardness in predicting diffuser deterioration. PMID:17706264

  5. In-well aeration -- An alternative to pump and treat

    SciTech Connect

    Harris, J.F.; Reisch, T.

    1999-07-01

    This report describes a pilot test of the NoVOCs{trademark} in-well aeration groundwater treatment technology at RCRA solid waste management unit (SWMU) 24 at Oceana Naval Air Station in Virginia Beach, Virginia. The pilot test ran for 15 weeks and operated at an average flow rate of 7 gpm. The analytical data for volatile organics suggest that the system was effective in substantially reducing the concentration of contaminants of concern (cis-1,2-DCE and TCE) during the 15 weeks of pilot test operation, especially within a 40 foot radius of the treatment well. The mass reduction caused by the system also appears to be substantial. Estimates from mass balance calculations suggest that from 22 to 76% of the mass of cis-1,2-DCE was removed from the groundwater over the duration of the pilot test. The system functioned well after an initial period of field testing and adjustments, although a slightly decreasing flow rate suggests that minor clogging due to oxidized iron occurred during the test.

  6. Atrazine removal from aqueous solutions using submerged biological aerated filter.

    PubMed

    Baghapour, Mohammad Ali; Nasseri, Simin; Derakhshan, Zahra

    2013-01-01

    Atrazine is widely used in the agriculture as an herbicide. Due to its high mobility, Atrazine leaks into the groundwaters, surface waters, and drinking water wells. Many physical and chemical methods have been suggested for removing Atrazine from aquatic environments. However, these methods are very costly, have many performance problems, produce a lot of toxic intermediates which are very harmful and dangerous, and cannot completely mineralize Atrazine. In this study, biodegradation of Atrazine by microbial consortium was evaluated in the aquatic environment. In order to assess the Atrazine removal from the aquatic environment, submerged biological aerated filter (SBAF) was fed with synthetic wastewater based on sucrose and Atrazine at different hydraulic retention times (HRTs). The maximum efficiencies for Atrazine and Soluble Chemical Oxygen Demand (SCOD) removal were 97.9% and 98.9%, respectively. The study findings showed that Stover-Kincannon model had very good fitness (R2 > 99%) in loading Atrazine in the biofilter and by increasing the initial concentration of Atrazine, the removal efficiency increased. Aerobic mixed biofilm culture was observed to be suitable for the treatment of Atrazine from aquatic environment. There was no significant inhibition effect on mixed aerobic microbial consortia. Atrazine degradation depended on the strength of wastewater and the amount of Atrazine in the influent. PMID:24499572

  7. Adsorption and desorption of uranium (VI) in aerated zone soil.

    PubMed

    Li, Xiaolong; Wu, Jiaojiao; Liao, Jiali; Zhang, Dong; Yang, Jijun; Feng, Yue; Zeng, Junhui; Wen, Wei; Yang, Yuanyou; Tang, Jun; Liu, Ning

    2013-01-01

    In this paper, the adsorption and desorption behavior of uranium (VI) in aerated zone soil (from Southwest China) was systematically investigated using a static experimental method in order to provide useful information for safety assessment of the disposal of (ultra-)low uraniferous radioactive waste, as well as a potential remediation method for uranium-contaminated soils. The adsorption behavior of uranium (VI) was firstly studied by batch experiments as functions of contact time, pH, liquid/solid ratio, temperature, colloids, minerals and coexistent ions. The results indicated that the adsorption of uranium (VI) by natural soil was efficient at an initial concentration of 10 mg/L uranium (VI) nitrate solution with 100 mg natural soil at room temperature when pH is about 7.0. The adsorption was strongly influenced by the solution pH, contact time, initial concentration and colloids. The adsorption equilibrium for uranium (VI) in soil was obtained within 24 h and the process could be described by the Langmuir adsorption equation. For uranium (VI) desorption, EDTA, citric acid and HNO(3) were evaluated under different conditions of temperature, concentration and proportion of liquid to solid. The adsorbed uranium (VI) on natural soil could be easily extracted by all these agents, especially by HNO(3), implying that the uranium-contaminated soils can be remedied by these reagents. PMID:22939949

  8. Lung Cancer

    MedlinePlus

    Lung cancer is one of the most common cancers in the world. It is a leading cause of ... in the United States. Cigarette smoking causes most lung cancers. The more cigarettes you smoke per day and ...

  9. Lung transplant

    MedlinePlus

    ... diseases that may require a lung transplant are: Cystic fibrosis Damage to the arteries of the lung because ... BC; Clinical Practice Guidelines for Pulmonary Therapies Committee; ... Therapies Committee. Cystic fibrosis pulmonary guidelines: ...

  10. Lung transplant

    MedlinePlus

    ... nih.gov/pubmed/20675678 . Kotloff RM, Keshavjee S. Lung transplantation. In: Broaddus VC, Mason RJ, Ernst MD, et ... 58. Solomon M, Grasemann H, Keshavjee S. Pediatric lung transplantation. Pediatr Clin North Am . 2010; 57(2):375- ...

  11. Lung surgery

    MedlinePlus

    ... Pneumonectomy; Lobectomy; Lung biopsy; Thoracoscopy; Video-assisted thoracoscopic surgery; VATS ... You will have general anesthesia before surgery. You will be asleep and unable to feel pain. Two common ways to do surgery on your lungs are thoracotomy and video- ...

  12. Effect of hydraulic loading rate on pollutant removal efficiency in subsurface infiltration system under intermittent operation and micro-power aeration.

    PubMed

    Yang, Yongqiang; Zhan, Xuan; Wu, Shijun; Kang, Mingliang; Guo, Jianan; Chen, Fanrong

    2016-04-01

    The low hydraulic loading rate (HLR) greatly restricts the wide application of subsurface wastewater infiltration system (SWIS) in densely populated areas. To increase the HLR, an innovative SWIS was developed using cyclic operation mode. In each cycle, a wastewater feeding period is followed by a drying period, in which the aeration is conducted by a medium-pressure fan. Results indicated that the removal rate of TOC and NH4(+)-N were more than 85% at HLR of 0.5m(3)/m(2)d, whereas the TN removal rate was lower than 20%, indicating that the aeration was efficient and denitrification process was largely limited in the SWIS. When HLR decreased from 0.5 to 0.2m(3)/m(2)d, the pollutant removal efficiency enhanced slightly except for TN. Overall, the intermittent operation and micro-power aeration, combined with shunting the pollutant loading were really helpful for SWIS to achieve higher HLR, which offers a reference for the design of innovative SWIS. PMID:26826957

  13. Perfluorocarbon-mediated aeration applied to recombinant protein production by virus-infected insect cells.

    PubMed

    Gotoh; Mochizuki; Kikuchi

    2001-01-01

    Perfluorocarbon (PFC) was used as an oxygen carrier in the cultures of insect cells and virus-infected insect cells. The cell suspensions were placed on a planar layer of PFC, which was re-oxygenated in an outer aeration unit and continuously recirculated, and were agitated by two sets of impeller blades, lower one of which was set in such a way that the ridge of the blade touched the PFC layer. The maximum cell density attained in the PFC-mediated aeration culture was higher than that in surface aeration culture. On viral infection, a recombinant protein yield was significantly high in the PFC-mediated aeration culture as compared with that in the surface aeration culture, though the production was largely decreased by setting apart the lower set of the blade from the PFC-medium interface. These results showed that the PFC-mediated aeration would be a useful technique for insect cell/baculovirus expression system. Overall mass-transfer coefficient K(L) for oxygen was examined in both the PFC-mediated aeration and surface aeration systems, by using a flask whose dimensions were identical to those of spinner flasks used for the cultures. The K(L) value in the PFC-mediated system was 2.60x10(-3)cms(-1), 1.6 times higher than that in the surface aeration system, when impeller blades were positioned at PFC-medium and medium-air interfaces, respectively. However, the K(L) values in both the PFC-mediated and surface aeration systems were decreased and their differences were brought so close, as the blade was set apart from the interfaces. DO behavior in the cultures was well explained by the model calculation using the determined K(L) values and oxygen-consumption rates of viable cells. This calculation further suggested that crucial DO, under which recombinant protein productions were unsuccessful, was 0.24-0.5ppm (3-7%) in the insect cell/baculovirus expression system. PMID:11150797

  14. Re-engineering the design criteria for sidestream elevated pool aeration

    SciTech Connect

    Farnan, J.C.

    1998-07-01

    The Metropolitan Water Reclamation District of Greater Chicago (District) has constructed five sidestream elevated pool aeration (SEPA) stations on the Calumet Waterway System (CWS) for replenishing dissolved oxygen (DO) in the waterway. A major component of the CWS is the Cal Sag Channel which has a width of 225 feet (68.6 meters) and a depth of 9 feet (2.7 meters). The CWS is a very slow moving waterway having a one foot drop in 37,000 feet (11.280 meters) which does not have the ability to maintain the Illinois Pollution Control Board's requirement of not less than 3 mg/l at any time. the need to raise the DO to the 3 mg/level led to the innovative design of SEPA stations which are also known as urban waterfall stations. The name urban waterfall is a term coined to describe a man made waterfall located in metropolitan areas. These urban waterfalls impart DO to the water similar to natural waterfalls. These stations were selected as the cost effective alternative to advanced wastewater treatment. Built at a cost of $40 million, the system saved taxpayers at least $260 million. This creative project brought the District its third ASCE Outstanding Civil Engineering Achievement Award in 1994.

  15. A rare case of esophageal lung in a neonate.

    PubMed

    Patil, Megharanjini; Sutagatti, Jagadish; Bhavikatti, Mohan; Nayak, Puneet V

    2016-01-01

    We report a rare case of esophageal lung in a neonate who presented with repeated chest infections and respiratory distress. Chest radiograph revealed increased opacification of the right lung with reduced lung volume and air bronchograms. Further evaluation with computed tomography (CT) showed the presence of only left mainstem bronchus at the tracheal bifurcation. Right mainstem bronchus originated from distal esophagus and aerated the right lung. Nasogastric tube was inserted into the stomach with injection of small amount of dilute barium through it, which established the communication of right mainstem bronchus with esophagus. Advanced CT scan imaging by virtual bronchoscopy and volume rendering further delineated the anatomical abnormality precisely prior to surgery. Surgical findings confirmed the diagnosis. PMID:27413267

  16. What Is Lung Cancer?

    MedlinePlus

    ... starts in the lungs, it is called lung cancer. Lung cancer begins in the lungs and may spread ... lung cancer. For more information, visit the National Cancer Institute’s Lung Cancer. Previous Basic Information Basic Information Basic Information ...

  17. High-sulfate, high-chemical oxygen demand wastewater treatment using aerated methanogenic fluidized beds

    SciTech Connect

    Zitomer, D.H.; Shrout, J.D.

    2000-02-01

    Many industrial wastewaters have both high organic pollution and sulfate (SO{sub 4}{sup {minus}2}) concentrations. Although biological conversion of organics to methane may be an economical chemical oxygen demand (COD) removal option, significant inhibition of methane production results from reduction of SO{sub 4}{sup {minus}2} to hydrogen sulfide (H{sub 2}S), which is inhibitory to methanogenic microorganisms. Therefore, sulfate-containing wastewater is often not amenable to conventional anaerobic treatment. Recently, limited aeration of recycle flow to hybrid and baffled reactors has been used to treat this wastewater and has been shown to reduce aqueous H{sub 2}S concentrations by causing production of uninhibitory sulfur (S{degree}) and thiosulfate (S{sub 2}O{sub 3}{sup {minus}2}) as well as gas stripping volatile H{sub 2}S. In this study, directly aerated methanogenic fluidized bed reactors (FBRs) achieved increased methane production compared to strictly anaerobic FBRs treating high-sulfate wastewater. Oxygen transfer satisfying up to 28% of the COD load resulted in maximum specific oxygen utilization rates of 0.20 mg oxygen/g volatile solids{center{underscore}dot}min, with significant, concomitant methane production. Under typically inhibitory SO{sub 4}{sup {minus}2} loading, higher aeration caused increased effluent SO{sub 4}{sup {minus}2}, increased H{sub 2}S mass in the offgas, and lower reactor H{sub 2}S concentration. As a result, COD removal increased from 25% for a strictly anaerobic FBR to 87% for an aerated FBR. In addition, aerated systems required significantly less alkalinity supplementation to maintain a pH value of 7, ostensibly because of stripping of acidic carbon dioxide. The potential pH increase associated with aeration also shifts sulfide speciation to less toxic disulfide. Direct, limited aeration of methanogenic FBRs is described as a method for increased COD removal when treating high-COD, high-sulfate wastewater.

  18. Reducing aeration energy consumption in a large-scale membrane bioreactor: Process simulation and engineering application.

    PubMed

    Sun, Jianyu; Liang, Peng; Yan, Xiaoxu; Zuo, Kuichang; Xiao, Kang; Xia, Junlin; Qiu, Yong; Wu, Qing; Wu, Shijia; Huang, Xia; Qi, Meng; Wen, Xianghua

    2016-04-15

    Reducing the energy consumption of membrane bioreactors (MBRs) is highly important for their wider application in wastewater treatment engineering. Of particular significance is reducing aeration in aerobic tanks to reduce the overall energy consumption. This study proposed an in situ ammonia-N-based feedback control strategy for aeration in aerobic tanks; this was tested via model simulation and through a large-scale (50,000 m(3)/d) engineering application. A full-scale MBR model was developed based on the activated sludge model (ASM) and was calibrated to the actual MBR. The aeration control strategy took the form of a two-step cascaded proportion-integration (PI) feedback algorithm. Algorithmic parameters were optimized via model simulation. The strategy achieved real-time adjustment of aeration amounts based on feedback from effluent quality (i.e., ammonia-N). The effectiveness of the strategy was evaluated through both the model platform and the full-scale engineering application. In the former, the aeration flow rate was reduced by 15-20%. In the engineering application, the aeration flow rate was reduced by 20%, and overall specific energy consumption correspondingly reduced by 4% to 0.45 kWh/m(3)-effluent, using the present practice of regulating the angle of guide vanes of fixed-frequency blowers. Potential energy savings are expected to be higher for MBRs with variable-frequency blowers. This study indicated that the ammonia-N-based aeration control strategy holds promise for application in full-scale MBRs. PMID:26905799

  19. Arsenic sorption in phosphate-amended soils during flooding and subsequent aeration

    SciTech Connect

    Reynolds, J.G.; Naylor, D.V.; Fendorf, S.E.

    1999-10-01

    Phosphate enhances the mobility of As in well-aerated soils by competing for adsorption sites. Phosphate and As may also coexist in large concentrations in hydric soils, and the influence of P on As in anaerobic systems is largely unknown. To determine the effects of P on As dynamics during a soil flooding and aeration cycle, samples of two soils were amended with Na{sub 2}HAsO{sub 4} and Na{sub 2}HPO, and incubated under a N{sub 2} atmosphere for 41 d, and then reaerated for 7 d. Subsamples were collected intermittently and dissolved As, Fe, Mn, Ca, S, P, and H{sub 3}AsO{sub 3} concentrations were determined. Arsenic speciation in the soil solids was determined after 14 and 41 d of flooding and then after 13 h of aeration by X-ray absorption near edge structure (XANES) spectroscopy. Arsenic sorption was small under anaerobic conditions, and H{sub 2}PO{sub 4}{sup {minus}} additions enhanced As(V) reduction rate in both soils and slightly suppressed As sorption in one soil. Arsenopyrite (FeAsS) was identified in the soil solids. Rapid and simultaneous As sorption and Fe precipitation occurred during the first 0.25 d of aeration, suggesting that As was retained on freshly precipitated Fe (hydr)oxides. Manganese precipitation and concomitant As sorption occurred after 1d of aeration. Arsenopyrite was largely destroyed upon aeration but As(III) persisted. Thus, As is partitioned into the solid phase under both aerobic and anaerobic conditions, although more appreciably under the aerobic conditions of this study, and P has little influence on dissolved As during soil flooding-aeration cycles.

  20. Lung Organogenesis

    PubMed Central

    Warburton, David; El-Hashash, Ahmed; Carraro, Gianni; Tiozzo, Caterina; Sala, Frederic; Rogers, Orquidea; De Langhe, Stijn; Kemp, Paul J.; Riccardi, Daniela; Torday, John; Bellusci, Saverio; Shi, Wei; Lubkin, Sharon R; Jesudason, Edwin

    2011-01-01

    Developmental lung biology is a field that has the potential for significant human impact: lung disease at the extremes of age continues to cause major morbidity and mortality worldwide. Understanding how the lung develops holds the promise that investigators can use this knowledge to aid lung repair and regeneration. In the decade since the “molecular embryology” of the lung was first comprehensively reviewed, new challenges have emerged—and it is on these that we focus the current review. Firstly, there is a critical need to understand the progenitor cell biology of the lung in order to exploit the potential of stem cells for the treatment of lung disease. Secondly, the current familiar descriptions of lung morphogenesis governed by growth and transcription factors need to be elaborated upon with the reinclusion and reconsideration of other factors, such as mechanics, in lung growth. Thirdly, efforts to parse the finer detail of lung bud signaling may need to be combined with broader consideration of overarching mechanisms that may be therapeutically easier to target: in this arena, we advance the proposal that looking at the lung in general (and branching in particular) in terms of clocks may yield unexpected benefits. PMID:20691848

  1. Dynamic imaging of the lungs using x-ray phase contrast

    NASA Astrophysics Data System (ADS)

    Lewis, R. A.; Yagi, N.; Kitchen, M. J.; Morgan, M. J.; Paganin, D.; Siu, K. K. W.; Pavlov, K.; Williams, I.; Uesugi, K.; Wallace, M. J.; Hall, C. J.; Whitley, J.; Hooper, S. B.

    2005-11-01

    High quality real-time imaging of lungs in vivo presents considerable challenges. We demonstrate here that phase contrast x-ray imaging is capable of dynamically imaging the lungs. It retains many of the advantages of simple x-ray imaging, whilst also being able to map weakly absorbing soft tissues based on refractive index differences. Preliminary results reported herein show that this novel imaging technique can identify and locate airway liquid and allows lung aeration in newborn rabbit pups to be dynamically visualized.

  2. Ambient iron-mediated aeration (IMA) for water reuse.

    PubMed

    Deng, Yang; Englehardt, James D; Abdul-Aziz, Samer; Bataille, Tristan; Cueto, Josenrique; De Leon, Omar; Wright, Mary E; Gardinali, Piero; Narayanan, Aarthi; Polar, Jose; Tomoyuki, Shibata

    2013-02-01

    Global water shortages caused by rapidly expanding population, escalating water consumption, and dwindling water reserves have rendered water reuse a strategically significant approach to meet current and future water demand. This study is the first to our knowledge to evaluate the technical feasibility of iron-mediated aeration (IMA), an innovative, potentially economical, holistic, oxidizing co-precipitation process operating at room temperature, atmospheric pressure, and neutral pH, for water reuse. In the IMA process, dissolved oxygen (O₂) was continuously activated by zero-valent iron (Fe⁰) to produce reactive oxygen species (ROS) at ambient pH, temperature, and pressure. Concurrently, iron sludge was generated as a result of iron corrosion. Bench-scale tests were conducted to study the performance of IMA for treatment of secondary effluent, natural surface water, and simulated contaminated water. The following removal efficiencies were achieved: 82.2% glyoxylic acid, ~100% formaldehyde as an oxidation product of glyoxylic acid, 94% of Ca²⁺ and associated alkalinity, 44% of chemical oxygen demand (COD), 26% of electrical conductivity (EC), 98% of di-n-butyl phthalate (DBP), 80% of 17β-estradiol (E2), 45% of total nitrogen (TN), 96% of total phosphorus (TP), 99.8% of total Cr, >90% of total Ni, 99% of color, 3.2 log removal of total coliform, and 2.4 log removal of E. Coli. Removal was attributed principally to chemical oxidation, precipitation, co-precipitation, coagulation, adsorption, and air stripping concurrently occurring during the IMA treatment. Results suggest that IMA is a promising treatment technology for water reuse. PMID:23232032

  3. Redistribution of pulmonary blood flow impacts thermodilution-based extravascular lung water measurements in a model of acute lung injury

    PubMed Central

    Easley, R. Blaine; Mulreany, Daniel G.; Lancaster, Christopher T.; Custer, Jason W.; Fernandez-Bustamante, Ana; Colantuoni, Elizabeth; Simon, Brett A.

    2009-01-01

    Background Studies using transthoracic thermodilution have demonstrated increased extravascular lung water (EVLW) measurements attributed to progression of edema and flooding during sepsis and acute lung injury. We hypothesize that redistribution of pulmonary blood flow can cause increased apparent EVLW secondary to increased perfusion of thermally silent tissue, not increased lung edema. Methods Anesthetized, mechanically ventilated canines were instrumented with PiCCO® (Pulsion Medical, Munich, Germany) catheters and underwent lung injury by repetitive saline lavage. Hemodynamic and respiratory physiologic data were recorded. After stabilized lung injury, endotoxin was administered to inactivate hypoxic pulmonary vasoconstriction. Computerized tomographic imaging was performed to quantify in vivo lung volume, total tissue (fluid) and air content, and regional distribution of blood flow. Results Lavage injury caused an increase in airway pressures and decreased arterial oxygen content with minimal hemodynamic effects. EVLW and shunt fraction increased after injury and then markedly following endotoxin administration. Computerized tomographic measurements quantified an endotoxin-induced increase in pulmonary blood flow to poorly aerated regions with no change in total lung tissue volume. Conclusions The abrupt increase in EVLW and shunt fraction after endotoxin administration is consistent with inactivation of hypoxic pulmonary vasoconstriction and increased perfusion to already flooded lung regions that were previously thermally silent. Computerized tomographic studies further demonstrate in vivo alterations in regional blood flow (but not lung water) and account for these alterations in shunt fraction and EVLW. PMID:19809280

  4. Effect of artificial aeration on the performance of vertical-flow constructed wetland treating heavily polluted river water.

    PubMed

    Dong, Huiyu; Qiang, Zhimin; Li, Tinggang; Jin, Hui; Chen, Weidong

    2012-01-01

    Three lab-scale vertical-flow constructed wetlands (VFCWs), including the non-aerated (NA), intermittently aerated (IA) and continuously aerated (CA) ones, were operated at different hydraulic loading rates (HLRs) to evaluate the effect of artificial aeration on the treatment efficiency of heavily polluted river water. Results indicated that artificial aeration increased the dissolved oxygen (DO) concentrations in IA and CA, which significantly favored the removal of organic matter and NH(4+)-N. The DO grads caused by intermittent aeration formed aerobic and anoxic regions in IA and thus promoted the removal of total nitrogen (TN). Although the removal efficiencies of COD(Cr), NH(4+)-N and TN in the three VFCWs all decreased with an increase in HLR, artificial aeration enhanced the reactor resistance to the fluctuation of pollutant loadings. The maximal removal efficiencies of COD(Cr), NH(4+)-N and total phosphorus (TP) (i.e., 81%, 87% and 37%, respectively) were observed in CA at 19 cm/day HLR, while the maximal TN removal (i.e., 57%) was achieved in IA. Although the improvement of artificial aeration on TP removal was limited, this study has demonstrated the feasibility of applying artificial aeration to VFCWs treating polluted river water, particularly at a high HLR. PMID:22894092

  5. Long-term ambient air pollution and lung function impairment in Chinese children from a high air pollution range area: The Seven Northeastern Cities (SNEC) study

    NASA Astrophysics Data System (ADS)

    Zeng, Xiao-Wen; Vivian, Elaina; Mohammed, Kahee A.; Jakhar, Shailja; Vaughn, Michael; Huang, Jin; Zelicoff, Alan; Xaverius, Pamela; Bai, Zhipeng; Lin, Shao; Hao, Yuan-Tao; Paul, Gunther; Morawska, Lidia; Wang, Si-Quan; Qian, Zhengmin; Dong, Guang-Hui

    2016-08-01

    Epidemiological studies have reported inconsistent and inconclusive associations between long-term exposure to ambient air pollution and lung function in children from Europe and America, where air pollution levels were typically low. The aim of the present study is to examine the relationship between air pollutants and lung function in children selected from heavily industrialized and polluted cities in northeastern China. During 2012, 6740 boys and girls aged 7-14 years were recruited in 24 districts of seven northeastern cities. Portable electronic spirometers were used to measure lung function. Four-year average concentrations of particulate matter with an aerodynamic diameter ≤10 μm (PM10), sulfur dioxide (SO2), nitrogen dioxide (NO2), and ozone (O3) were measured at monitoring stations in the 24 districts. Two-staged regression models were used in the data analysis, controlling for covariates. Overall, for all subjects, the increased odds of lung function impairment associated with exposure to air pollutants, ranged from 5% (adjusted odds ratio [aOR] = 1.05; 95% confidence interval [CI] = 1.01, 1.10) for FVC < 85% predicted per 46.3 μg/m3 for O3 to 81% (aOR = 1.81; 95%CI = 1.44, 2.28) for FEV1 < 85% predicted per 30.6 μg/m3 for PM10. The linear regression models consistently showed a negative relationship between all air pollutants and lung function measures across subjects. There were significant interaction terms indicating gender differences for lung function impairment and pulmonary function from exposure to some pollutants (P < 0.10). In conclusion, long term exposure to high concentrations of ambient air pollution is associated with decreased pulmonary function and lung function impairment, and females appear to be more susceptible than males.

  6. Rapid Start-up and Loading of an Attached Growth, Simultaneous Nitrification/Denitrification Membrane Aerated Bioreactor

    NASA Technical Reports Server (NTRS)

    Meyer, Caitlin E.; Pensinger, Stuart; Pickering, Karen D.; Barta, Daniel; Shull, Sarah A.; Vega, Letticia M.; Christenson, Dylan; Jackson, W. Andrew

    2015-01-01

    Membrane aerated bioreactors (MABR) are attached-growth biological systems used for simultaneous nitrification and denitrification to reclaim water from waste. This design is an innovative approach to common terrestrial wastewater treatments for nitrogen and carbon removal and implementing a biologically-based water treatment system for long-duration human exploration is an attractive, low energy alternative to physiochemical processes. Two obstacles to implementing such a system are (1) the "start-up" duration from inoculation to steady-state operations and (2) the amount of surface area needed for the biological activity to occur. The Advanced Water Recovery Systems (AWRS) team at JSC explored these two issues through two tests; a rapid inoculation study and a wastewater loading study. Results from these tests demonstrate that the duration from inoculation to steady state can be reduced to under two weeks, and that despite low ammonium removal rates, the MABRs are oversized.

  7. Limited aeration of methanogenic systems for treatment of sulfate-containing wastewater

    SciTech Connect

    Zitomer, D.H.; Shrout, J.D.

    1998-07-01

    Wastewaters with high sulfate concentrations are often not readily amenable to methanogenic treatment due to production of potentially inhibitory hydrogen sulfide. Some reports indicate that treatment has been enhanced by air sparging of recycle flows to air-strip hydrogen sulfide and create a selective environment for reduction of sulfate to elemental sulfur, rather than sulfides and thiosulfate. In this report, direct aeration of methanogenic expanded beds was employed for treatment of high-sulfate wastewater and compared to a strictly anaerobic control. An influent wastewater COD:SO{sup {minus}2}{sub 4} ratio as low as 4,4:1 did not discernibly inhibit methane production in the anaerobic control. At a relatively high OLR of 30g COD/L{sub A}-d and a relatively short HRT of 4.2 hours, the COD removal of the control was 97%. Methanogenesis was also sustained in the aerated reactors which had oxygen transfer rates of between 2 to 5% of the OLR. These aerated reactors converted approximately 70% of the COD to methane. Future research will involve higher sulfate loadings and aeration rates to determine possible benefits of direct aeration of methanogenic expanded beds.

  8. Development of a stepwise aeration control strategy for efficient docosahexaenoic acid production by Schizochytrium sp.

    PubMed

    Ren, Lu-Jing; Ji, Xiao-Jun; Huang, He; Qu, Liang; Feng, Yun; Tong, Qian-Qian; Ouyang, Ping-Kai

    2010-08-01

    The effect of aeration on the performance of docosahexaenoic acid (DHA) production by Schizochytrium sp. was investigated in a 1,500-L bioreactor using fed-batch fermentation. Six parameters, including specific growth rate, specific glucose consumption rate, specific lipid accumulation rate, cell yield coefficient, lipid yield coefficient, and DHA yield coefficient, were used to understand the relationship between aeration and the fermentation characteristics. Based on the information obtained from the parameters, a stepwise aeration control strategy was proposed. The aeration rate was controlled at 0.4 volume of air per volume of liquid per minute (vvm) for the first 24 h, then shifted to 0.6 vvm until 96 h, and then switched back to 0.4 vvm until the end of the fermentation. High cell density (71 g/L), high lipid content (35.75 g/L), and high DHA percentage (48.95%) were achieved by using this strategy, and DHA productivity reached 119 mg/L h, which was 11.21% over the best results obtained by constant aeration rate. PMID:20445973

  9. Aeration strategy: a need for very high ethanol performance in Saccharomyces cerevisiae fed-batch process.

    PubMed

    Alfenore, S; Cameleyre, X; Benbadis, L; Bideaux, C; Uribelarrea, J-L; Goma, G; Molina-Jouve, C; Guillouet, S E

    2004-02-01

    In order to identify an optimal aeration strategy for intensifying bio-fuel ethanol production in fermentation processes where growth and production have to be managed simultaneously, we quantified the effect of aeration conditions--oxygen limited vs non limited culture (micro-aerobic vs aerobic culture)--on the dynamic behaviour of Saccharomyces cerevisiae cultivated in very high ethanol performance fed-batch cultures. Fermentation parameters and kinetics were established within a range of ethanol concentrations (up to 147 g l(-1)), which very few studies have addressed. Higher ethanol titres (147 vs 131 g l(-1) in 45 h) and average productivity (3.3 vs 2.6 g l(-1) h(-1)) were obtained in cultures without oxygen limitation. Compared to micro-aerobic culture, full aeration led to a 23% increase in the viable cell mass as a result of the concomitant increase in growth rate and yield, with lower ethanol inhibition. The second beneficial effect of aeration was better management of by-product production, with production of glycerol, the main by-product, being strongly reduced from 12 to 4 g l(-1). We demonstrate that aeration strategy is as much a determining factor as vitamin feeding (Alfenore et al. 2002) in very high ethanol performance (147 g l(-1) in 45 h) in order to achieve a highly competitive dynamic process. PMID:12879304

  10. Raising and controlling study of dissolved oxygen concentration in closed-type aeration tank.

    PubMed

    Chen, C K; Lo, S L

    2005-07-01

    This study investigated the promotion and control of dissolved oxygen (DO) concentration of the closed-type aeration tank via practical experiments in the wastewater treatment system of a 5-star hotel in Taipei. As with limited and treasured space in Taiwan, before the completion of the sewer system construction in cities, to utilize the mat foundation under large buildings as the space of sewage treatment plant still has been one of the alternatives of those sewage treatments. However, aeration tanks constructed in the mat foundation of buildings have smaller effective water depth, which will cause a lower total transfer amount of DO. Controlling the total exhaust gas flow rate can increase the pressure on such closed-type aeration tanks. The DO concentration thus may increase according to Henry's Law. Furthermore, it may enable operators to adjust the DO concentration of the aeration tank more precisely and thus sustain optimal operating conditions in these treatment facilities. Practical experiments indicated that the DO concentration of aeration tank maintains an average of 3.8 mg l(-1), obtaining the optimum operating conditions. The efficiency of the biological treatment facilities in the mat foundation could be markedly improved. PMID:16080335

  11. Aerated Shewanella oneidensis in continuously fed bioelectrochemical systems for power and hydrogen production.

    PubMed

    Rosenbaum, Miriam; Cotta, Michael A; Angenent, Largus T

    2010-04-01

    We studied the effects of aeration of Shewanella oneidensis on potentiostatic current production, hydrogen production in a microbial electrolysis cell, and electric power generation in a microbial fuel cell (MFC). The potentiostatic performance of aerated S. oneidensis was considerably enhanced to a maximum current density of 0.45 A/m(2) or 80.3 A/m(3) (mean: 0.34 A/m(2), 57.2 A/m(3)) compared to anaerobically grown cultures. Biocatalyzed hydrogen production rates with aerated S. oneidensis were studied within the applied potential range of 0.3-0.9 V and were highest at 0.9 V with 0.3 m(3) H(2)/m(3) day, which has been reported for mixed cultures, but is approximately 10 times higher than reported for an anaerobic culture of S. oneidensis. Aerated MFC experiments produced a maximum power density of 3.56 W/m(3) at a 200-Omega external resistor. The main reasons for enhanced electrochemical performance are higher levels of active biomass and more efficient substrate utilization under aerobic conditions. Coulombic efficiencies, however, were greatly reduced due to losses of reducing equivalents to aerobic respiration in the anode chamber. The next challenge will be to optimize the aeration rate of the bacterial culture to balance between maximization of bacterial activation and minimization of aerobic respiration in the culture. PMID:19998276

  12. Volatile organic compound emission rates from mechanical surface aerators: Mass-transfer modeling

    SciTech Connect

    Chern, J.M.; Chou, S.R.

    1999-08-01

    In wastewater treatment plants, many operation units such as equalization and aeration involve oxygen transfer between wastewater and air. While oxygen is transferred from air to wastewater, volatile organic compounds (VOCs) are stripped from wastewater to air. Because of increasingly stringent environmental regulations, wastewater treatment operators have to do VOC inventory of their facilities. A new mass-transfer model has been developed to predict the VOC emission rates from batch and continuous aeration tanks with mechanical surface aerators. The model takes into consideration that the VOC mass transfer occurs in two separate mass-transfer zones instead of lumping the overall VOC transfer in the whole aeration tank as is done in the conventional ASCE-based model. The predictive capabilities of the two-zone and the ASCE-based models were examined by calculating the emission rates of 10 priority pollutants from aeration tanks. The effects of the hydraulic retention time, the Henry`s law constant, gas-phase resistance, and the water and air environmental conditions on the VOC emission rates were predicted by the two models.

  13. Nitrogen transformations and retention in planted and artificially aerated constructed wetlands.

    PubMed

    Maltais-Landry, Gabriel; Maranger, Roxane; Brisson, Jacques; Chazarenc, Florent

    2009-02-01

    Nitrogen (N) processing in constructed wetlands (CWs) is often variable, and the contribution to N loss and retention by various pathways (nitrification/denitrification, plant uptake and sediment storage) remains unclear. We studied the seasonal variation of the effects of artificial aeration and three different macrophyte species (Phragmites australis, Typha angustifolia and Phalaris arundinacea) on N processing (removal rates, transformations and export) using experimental CW mesocosms. Removal of total nitrogen (TN) was higher in summer and in planted and aerated units, with the highest mean removal in units planted with T. angustifolia. Export of ammonium (NH(4)(+)), a proxy for nitrification limitation, was higher in winter, and in unplanted and non-aerated units. Planted and aerated units had the highest export of oxidized nitrogen (NO(y)), a proxy for reduced denitrification. Redox potential, evapotranspiration (ETP) rates and hydraulic retention times (HRT) were all predictors of TN, NH(4)(+) and NO(y) export, and significantly affected by plants. Denitrification was the main N sink in most treatments accounting for 47-62% of TN removal, while sediment storage was dominant in unplanted non-aerated units and units planted with P. arundinacea. Plant uptake accounted for less than 20% of the removal. Uncertainties about the long-term fate of the N stored in sediments suggest that the fraction attributed to denitrification losses could be underestimated in this study. PMID:19036399

  14. Monitoring transitory profiles of leachate humic substances in landfill aeration reactors in mesophilic and thermophilic conditions.

    PubMed

    Tong, Huanhuan; Yin, Ke; Ge, Liya; Giannis, Apostolos; Chuan, Valerie W L; Wang, Jing-Yuan

    2015-04-28

    The presence of humic substances (HS) in landfill leachate is of great interest because of their structural stability and potential toxicity. This study examined the effects of temperature and waste age on the transformation of HS during in situ aeration of bioreactor landfills. By establishing aerobic conditions, dissolved organic carbon (DOC) rapidly accumulated in the bioreactor leachate. Fractional analysis showed that the elevated concentration of humic acids (HAs) was primarily responsible for the increment of leachate strength. Further structural characterization indicated that the molecular weight (MW) and aromacity of HS were enhanced by aeration in conjunction with thermophilic temperature. Interestingly, elevation of HAs concentration was not observed in the aeration reactor with a prolonged waste age, as the mobility of HAs was lowered by the high MW derived from extended waste age. Based on these results, aeration may be more favorable in aged landfills, since dissolution of HAs could be minimized by the evolution to larger MW compared to young landfills. Moreover, increased operation temperature during aeration likely offers benefits for the rapid maturation of HS. PMID:25682368

  15. [Effect of Intermittent Aeration on Nitrogen Removal Efficiency in Vertical Subsurface Flow Constructed Wetland].

    PubMed

    Wang, Jian; Li, Huai-zheng; Zhen, Bao-chong; Liu, Zhen-dong

    2016-03-15

    One-stage vertical subsurface flow constructed wetlands (CWs) were used to treat effluent from grit chamber in municipal wastewater treatment plant. The CW was divided into aerobic zone and anoxic zone by means of raising the effluent level and installing a perforated pipe. Two parameters (the ratio of aeration time and nonaeration time, aeration cycle) were optimized in the experiment to enhance nitrogen removal efficiency. The results suggested that the removal rates of COD and NH₄⁺-N increased while TN showed a trend of first increasing and then decreasing with the increasing ratio. When the ratio was 3:1, the C/N value in the anoxic zone was 4. 8. And the TN effluent concentration was 15.8 mg · L⁻¹ with the highest removal rate (62.1%), which was increased by 12.7% compared with continuous aeration. As the extension of the aeration cycle, the DO effluent concentration as well as the removal rates of COD and NH: -N declined gradually. The TN removal rate reached the maximum (65.5%) when the aeration cycle was 6h. However, the TN removal rate dropped rapidly when the cycle exceeded the hydraulic retention time in the anoxic zone. PMID:27337890

  16. [Lung ultrasound in the newborn].

    PubMed

    Yousef, N

    2016-03-01

    Lung ultrasound (LU) is becoming a bedside point-of-care technique in critical care and emergency medicine as it is performed and immediately interpreted by the clinician. LU is quick, easy, relatively inexpensive, and provides accurate diagnostic information when compared with conventional lung imaging methods, such as CT scans and chest radiographs, with the additional advantage of being non-irradiating, adapted to bedside use, and easily repeatable with no side effects for the patient. LU is easy to learn, does not require sophisticated ultrasound machines or settings, and shows low intra- and interobserver variability when a standardized approach is used. A comprehensive and standardized ultrasound semiology has been described and validated in both adults and children. In summary, LU allows for quick easy recognition of a normally aerated lung in contrast to an interstitial or alveolar pattern. Recognition of these patterns may be even easier in neonates due to their small size and the absence of obesity and heavy musculature. Specific LU findings have been described for some types of neonatal lung injury, such as neonatal respiratory distress syndrome, transient tachypnea of the neonate, meconium aspiration syndrome, and neonatal pneumonia. In the newborn, LU has proved its usefulness in predicting the need for hospital admission and/or intubation based on simple LU patterns. A recently proposed LU score, adapted for the neonate, correlates well with oxygenation status, independently of gestational age and underlying respiratory condition. The score reliably predicts the need for surfactant treatment in preterm babies less than 34 weeks gestation treated with nasal CPAP from birth. LU is a promising tool with numerous potential applications that warrant future studies. However, like every technique, LU has its limitations and should not completely replace standard radiography. LU can nevertheless largely reduce exposure to ionizing radiation by limiting the

  17. [Effect of intermittent artificial aeration on nitrogen and phosphorus removal in subsurface vertical-flow constructed wetlands].

    PubMed

    Tang, Xian-qiang; Li, Jin-zhong; Li, Xue-Ju; Liu, Xue-gong; Huang, Sui-liang

    2008-04-01

    Shale and T. latifolia were used as subsurface vertical-flow constructed wetland substrate and vegetation for eutrophic Jin River water treatment, and investigate the effect of intermittent aeration on nitrogen and phosphorus removal. In this study, hydraulic loading rate was equal to 800 mm/d, and ratio of air and water was 5:1. During the entire running period, maximal monthly mean ammonia-nitrogen (NH4+ -N), total nitrogen (TN), soluble reactive phosphorus (SRP) and total phosphorus (TP) removal rates were observed in August 2006. In contrast to the non-aerated wetland, aeration enhanced ammonia-nitrogen, total nitrogen, soluble reactive phosphorus and total phosphorus removal: 10.1%, 4.7%, 10.2% and 8.8% for aeration in the middle, and 25.1%, 10.0%, 7.7% and 7.4% for aeration at the bottom of the substrate, respectively. However, aeration failed to improve the nitrate-nitrogen removal. During the whole experimental period, monthly mean NO3(-) -N removal rates were much lower for aerated constructed wetlands (regarding aeration in the middle and at the bottom) than those for non-aerated system. After finishing the experiment, aboveground plant biomass (stems and leaves) of T. latifolia was harvested, and its weight and nutrient content (total nitrogen and total phosphorus) were measured. Analysis of aboveground plant biomass indicated that intermittent aeration restrained the increase in biomass but stimulated assimilation of nitrogen and phosphorus into stems and leaves. Additional total nitrogen removal of 11.6 g x m(-2) and 12.6 g x m(-2) by aboveground T. latifolia biomass for intermittent artificial aeration in the middle and at the bottom of the wetland substrate, respectively, was observed. PMID:18637335

  18. Study of biological aerated filters for the treatment of effluents from the citrus industry.

    PubMed

    Osorio, Francisco; Torres, Juan C; Hontoria, Ernesto

    2006-01-01

    The primary objective of this research study was to test the applicability and optimize the design parameters of a system of biological aerated filters in order to obtain an optimal effluent from the citrus industry, which would allow its drainage into the municipal sewer system. Expanded clay was used as a support material. After experimenting with both countercurrent and cocurrent flows as well different aeration levels, it was found that cocurrent flow was more efficient. Backwashing was carried out on a daily basis. The results of our study showed that for an aeration of 10.47 Nm3/h/m2, the volumetric load should be less than 20 Kg. COD/m3/d in order to obtain an effluent with a maximum concentration of 600 mgCOD/L, and the hydraulic load should be less than 0.36 m/h. PMID:17114100

  19. RBF methods for solving laterally averaged Saint Venant equations: application to eutrophication prevention through aeration

    NASA Astrophysics Data System (ADS)

    Halassi, A.; Ouazar, D.; Taik, A.

    2015-10-01

    A vertical 2Dxz laterally averaged hydrodynamic model is presented in this paper to study the aeration process in lakes. The system exhibits highly nonlinear behaviour due to the phenomena involved such as stratification, air concentration, and convective terms. The suggested model is used to simulate mechanical aeration to overcome and prevent the eutrophication in lakes. The multiquadric radial basis functions are used to solve numerically the governing partial differential equations. Because of the difficulty and the complexity when choosing a suitable shape parameter in radial basis functions, an alternative way is introduced in this work to overcome these difficulties. A validation study is carried out using several test examples, including Poisson, Navier-Stokes and transport equations. Finally, the proposed model is first applied to simulate a squared domain aeration problem and then a real test case has been considered. The obtained results are in good agreement with the results reported in the literature.

  20. Wastewater treatment with bacteria immobilized onto a ceramic carrier in an aerated system.

    PubMed

    Kariminiaae-Hamedaani, Hamid-Reza; Kanda, Kohzo; Kato, Fumio

    2003-01-01

    Biological treatment of the wastewater discharged from a food processing factory was continuously carried out in a packed bed bioreactor under aerobic conditions. The bacterium isolated from the wastewater was immobilized onto a new type of ceramic carrier by a vacuum method and high numbers of bacteria were colonized onto the carrier (2.9 x 10(9) cfu/g of dry ceramic carrier). The effect of the hydraulic retention time (HRT) and aeration rate on the removal of the chemical oxygen demand (COD) was investigated. The system was able on average to remove more than 82% of the influent COD during 160 d of operation and more than 87% of the influent COD on average was removed when the HRT was 30.17 h and the aeration rate was 2.0 vvm. Aeration rates in the range of 0.4 to 2.0 vvm do not affect the COD removal efficiency. PMID:16233380

  1. Lung cancer.

    PubMed

    Akhurst, Tim; MacManus, Michael; Hicks, Rodney J

    2015-04-01

    (18)F-fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) plays a key role in the evaluation of undiagnosed lung nodules, when primary lung cancer is strongly suspected, or when it has already been diagnosed by other techniques. Although technical factors may compromise characterization of small or highly mobile lesions, lesions without apparent FDG uptake can generally be safely observed, whereas FDG-avid lung nodules almost always need further evaluation. FDG-PET/CT is now the primary staging imaging modality for patients with lung cancer who are being considered for curative therapy with either surgery or definitive radiation therapy. PMID:25829084

  2. Farmer's lung

    PubMed Central

    Hapke, E. J.; Seal, R. M. E.; Thomas, G. O.; Hayes, M.; Meek, J. C.

    1968-01-01

    In assessing patients suffering from farmer's lung, the acute stage must be distinguished from the chronic stage of the disease. The conspicuous radiographic signs in the acute farmer's lung episode and the often dramatic clearing make an important contribution to the diagnosis. The radiographic changes in chronic farmer's lung are not specific and cover a wide range of appearances. Even minor nodular changes are significant. Farmer's lung, acute and chronic, is not a disease predominantly characterized by a defect in gas exchange. During the acute illness the reduction in diffusing capacity is often accompanied by a decrease in lung volumes; the pulmonary function profile of the chronic stage is variable. In only a relatively small proportion of chronic farmer's lung patients does a defect in gas exchange predominate, and in some it may be manifest only during exercise. Airway obstruction is a feature of chronic farmer's lung. In chronic farmer's lung patients discrepancies between the severity of complaints and results of pulmonary function tests are not infrequent. In some patients with considerable disability conventional pulmonary function studies may demonstrate little or no impairment of the functions measured. In patients suffering from an acute farmer's lung episode, serological tests should be positive, possibly in high titre. In the chronic stage of the disease the chance of finding positive serology in a patient diminishes with the length of time elapsed since the last acute episode. The period of serological transition appears to be the third year. Images PMID:4971361

  3. Aeration of anaerobically digested sewage sludge for COD and nitrogen removal: optimization at large-scale.

    PubMed

    Parravicini, V; Svardal, K; Hornek, R; Kroiss, H

    2008-01-01

    The paper will report about the experiences at an Austrian large wastewater treatment plant of 720,000 population equivalents, where anaerobically digested sewage sludge is further stabilised under aerobic conditions. Enhanced stabilisation of the anaerobically digested sludge was required at the plant in order to get a permit for landfill disposal of the dewatered stabilized sludge. By implementing a post-aeration treatment (SRT approximately 6d; 36 degrees C) after anaerobic digestion the organic content of the anaerobically well digested sludge can be decreased by 16%. Investigations on site showed that during digested sludge post-aeration anoxic phases for denitrification are needed to provide stable process conditions. In this way the pH value can be kept in a more favourable range for micro-organisms and concrete structures. Additionally, inhibition of the biological process due to nitrite accumulation can be avoided. By optimising the aeration/pause ratio approximately 45% of total nitrogen in digested sludge can be removed. This significantly improves nitrogen removal efficiency at the wastewater treatment plant. NH(4)-removal occurs mainly through nitritation and denitritation with an efficiency of 98%. The costs/benefit analysis shows that post-aeration of digested sludge results in an increase of total annual costs for wastewater treatment of only 0.84%, corresponding to 0.19 Euro/pe/a. Result of molecular biological analyses (DGGE) indicate that all four ammonium-oxidizing bacteria species present in activated sludge can survive anaerobic digestion, but only two of them can adapt in the digested sludge post-aeration tanks. Additionally, in the post-aerated digested sludge a further ammonium-oxidizing bacteria species was identified. PMID:18235180

  4. [Effect of aeration and inulin concentration on ethanol production by Kluyveromyces marxinaus YX01].

    PubMed

    Gao, Jiaoqi; Yuan, Wenjie; Chen, Lijie; Han, Xitong; Bai, Fengwu

    2013-03-01

    Consolidated bioprocessing technology can be used for Kluyveromyces marxianus YX01 to produce ethanol from Jerusalem artichoke, which is one of the potential processes to produce biofuel from non-cereal crops. In this study, we combined the aeration rate with the substrate concentration to conduct cross-over experiments for K. marxinaus YX01, and studied ethanol fermentation and the influence of inulin enzyme activity. The substrate concentration had a little repressive effect on ethanol productivity. When substrate concentration reached 250 g/L under anaerobic conditions, ethanol concentration was 84.8 g/L, and ethanol yield was reduced from 86.4% (50 g/L substrate concentration) to 84.7% of the theoretical value. Aeration rate could accelerate K. marxinaus YX01 ethanol fermentation, but reduced ethanol yield. When substrate concentration reached 250 g/L under aeration at 1.0 vvm, ethanol yield was reduced from 84.7% under anaerobic conditions to 73.3% of the theoretical value. With increased concentration of the carbon source and reduced aeration rate, the inulinase of K. marxinaus YX01 reduced and the concentration of glycerol increased, however, the acetic acid increased with the increased concentration of the carbon source and aeration rate. When substrate concentration reached 250 g/L under anaerobic conditions, inulinase activity was only 6.59 U/mL; when substrate concentration reached 50 g/L under aeration at 1.0 vvm, inulinase activity was 21.54 U/mL. PMID:23789273

  5. Relationship between ecosystem respiration and aeration constant in open channel dissolved oxygen analysis

    NASA Astrophysics Data System (ADS)

    Parker, S. J.; Butler, A. P.; Heppell, C. M.

    2015-12-01

    Using the open channel diel method of Odum (1956) and the night-time regression method (Hornberger and Kelly, 1985), we analysed a time series of dissolved oxygen (DO) in two slow flowing streams for a two month period in summer 2014 and obtained values for ecosystem respiration and the aeration constant for each day in the period. We then used the standard dissolved oxygen lumped model to generate a DO time series behaviour for one of those rivers selecting respiration and aeration parameters by randomly sampling from the values obtained from the data. Two synthetic time series were created, one where respiration and aeration were independent of temperature and a second where respiration and aeration were affected by temperature according to the modified Arrhenius relationship. With these two synthetic time series, we again recovered the respiration and aeration input parameters using the night- time regression method and compared those recovered parameters with the input parameters. Because the simulations were conducted with parameters that were known, the values recovered using the night-time regression method (i.e post-simulation) could be compared with parameters driving the simulation (i.e. pre-simulation input values). For values based on data, we found a strong correlation between the aeration constant and respiration for both rivers. For the synthetic time series, no such correlation was found, either with the temperature independent or temperature dependent time series. The night-time regression method also recovered perfectly the input parameters, so the correlation was not brought about as a result of implementing the method itself. We are currently investigating the cause of the correlation.

  6. Volatile emissions during storing of green food waste under different aeration conditions.

    PubMed

    Agapiou, A; Vamvakari, J P; Andrianopoulos, A; Pappa, A

    2016-05-01

    Controlled field experiments were carried out for monitoring the emissions of three plastic commercial household waste bins, which were adapted for studying the effect of aeration process in the evolved volatiles, during house storing of green food waste for 2 weeks, prior to collection. Three experimental scenarios were examined based on no aeration ("NA," closed commercial waste bin), diffusion-based aeration ("DA," closed commercial waste bin with tiny holes), and enforced aeration ("EA," closed commercial waste bin with tiny holes and enforced aeration). The monitoring of volatile organic compounds (VOCs) emitted from organic household kitchen waste was performed using solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) analysis. Portable sensors were also used for monitoring selected gases and parameters of environmental, bioprocess, and health interest (e.g., CO2, O2, H2S, CH4, NH3, % RH, waste temperatures). VOC emissions are strongly dependent on the waste material. The most frequent VOCs identified over the storing waste, showing over 50 % appearance in all examined samples, were terpenes (e.g., di-limonene, beta-myrcene, delta-3-carene, alpha-pinene, alpha-terpinolene, linalool, etc.), sulfides (dimethyl disulfide), aromatics (benzene, 1-methyl-2-(2-propenyl)), alkanes (e.g., decane, dodecane), ketones (2-propanone), esters (e.g., acetic acid ethyl ester, acetic acid methyl ester), and alcohols (e.g., 3-cyclohexen-1-ol, 4-methyl-1-(1-methylethyl)). The prominent role of terpenes in the "pre-compost" odor and especially that of di-limonene was highlighted. In all examined scenarios, the emitted volatiles were increased at raised temperatures and later decreased in time. Aeration of waste bins slightly affected the volatilization process resulting in higher profiles of VOCs; uniformity in the composition of VOCs was also noted. Slight modifications of commercial waste bins may favor the initiation of home composting. PMID

  7. EFFECTS OF ETIOLOGICALLY DEFINED RESPIRATORY INFECTIONS ON LUNG FUNCTION AND ITS GROWTH IN AN AREA OF LOW AIR POLLUTION - SPIROMETRY IN YOUNG CHILDREN WHEN ILLNESS-FREE

    EPA Science Inventory

    This longitudinal study was performed in a group of 3-12 year old children to document normal lung growth patterns as measured by spirometry. By clinical and laboratory parameters, these children were free of illness at the time of study and had been for the preceding 21 days. Sp...

  8. Investigation of Hydrogen Sulfide Exposure and Lung Function, Asthma and Chronic Obstructive Pulmonary Disease in a Geothermal Area of New Zealand

    PubMed Central

    Bates, Michael N.; Crane, Julian; Balmes, John R.; Garrett, Nick

    2015-01-01

    Background Results have been conflicting whether long-term ambient hydrogen sulfide (H2S) affects lung function or is a risk factor for asthma or chronic obstructive pulmonary disease (COPD). Rotorua city, New Zealand, has the world’s largest population exposed to ambient H2S—from geothermal sources. Objectives We investigated associations of H2S with lung function, COPD and asthma in this population. Methods 1,204 of 1,639 study participants, aged 18–65 years during 2008–2010, provided satisfactory spirometry results. Residences, workplaces and schools over the last 30 years were geocoded. Exposures were estimated from data collected by summer and winter H2S monitoring networks across Rotorua. Four metrics for H2S exposure, representing both current and long-term (last 30 years) exposure, and also time-weighted average and peak exposures, were calculated. Departures from expected values for pre-bronchodilator lung function, calculated from prediction equations, were outcomes for linear regression models using quartiles of the H2S exposure metrics. Separate models examined participants with and without evidence of asthma or COPD, and never- and ever-smokers. Logistic regression was used to investigate associations of COPD (a post-bronchodilator FEV1/FVC < 70% of expected) and asthma (doctor-diagnosed or by FEV1 response to bronchodilator) with H2S exposure quartiles. Results None of the exposure metrics produced evidence of lung function decrement. The logistic regression analysis showed no evidence that long-term H2S exposure at Rotorua levels was associated with either increased COPD or asthma risk. Some results suggested that recent ambient H2S exposures were beneficially associated with lung function parameters. Conclusions The study found no evidence of reductions in lung function, or increased risk of COPD or asthma, from recent or long-term H2S exposure at the relatively high ambient concentrations found in Rotorua. Suggestions of improved lung

  9. Pathways of nitrobenzene degradation in horizontal subsurface flow constructed wetlands: Effect of intermittent aeration and glucose addition.

    PubMed

    Kirui, Wesley K; Wu, Shubiao; Kizito, Simon; Carvalho, Pedro N; Dong, Renjie

    2016-01-15

    Intermittent aeration and addition of glucose were applied to horizontal subsurface flow constructed wetlands in order to investigate the effect on pathways of nitrobenzene (NB) degradation and interactions with microbial nitrogen and sulphur transformations. The experiment was carried out in three phases A, B and C consisting of different NB loading and glucose dosing. For each phase, the effect of aeration was assessed by intermittently aerating one wetland and leaving one unaerated. Regardless of whether or not the wetland was aerated, at an influent NB concentration of 140 mg/L, both wetlands significantly reduced NB to less than 2 mg/L, a reduction efficiency of 98%. However, once the influent NB concentration was increased to 280 mg/L, the aerated wetland had a higher removal performance 82% compared to that of the unaerated wetland 71%. Addition of glucose further intensified the NB removal to 95% in the aerated wetlands and 92% in the unaerated. Aeration of wetlands enhanced NB degradation, but also resulted in higher NB volatilization of 6 mg m(-2) d(-1). The detected high concentration of sulphide 20-60 mg/L in the unaerated wetland gave a strong indication that NB may act as an electron donor to sulphate-reducing bacteria, but this should be further investigated. Aeration positively improved NB removal in constructed wetlands, but resulted in higher NB volatilization. Glucose addition induced co-metabolism to enhance NB degradation. PMID:26468606

  10. Functional linkage between N acquisition strategies and aeration capacities of hydrophytes for efficient oxygen consumption in roots.

    PubMed

    Nakamura, Motoka; Nakamura, Takatoshi; Tsuchiya, Takayoshi; Noguchi, Ko

    2013-02-01

    We evaluated the specific strategies of hydrophytes for root O(2) consumption in relation to N acquisition and investigated whether the strategies varied depending on the aeration capacity. Aeration capacity of roots is an important factor for determining hypoxia tolerance in plants. However, some hydrophytes possessing quite different aeration capacities often co-occur in wetlands, suggesting that root O(2) consumption also strongly affects hypoxia tolerance. We cultivated Phragmites australis with high aeration capacity and Zizania latifolia with low aeration capacity in hypoxic conditions with NH(4)(+) or NO(3)(-) treatment and compared the growth, N uptake, N assimilation and root respiration between the two species. In Z. latifolia grown with NH(4)(+) treatment, high N uptake activity and restrained root growth led to sufficient N acquisition and decrease in whole-root respiration rate. These characteristics consequently compensated for the low aeration capacity. In contrast, in P. australis, low N uptake activity was compensated by active root growth, but the whole-root respiration rate was high. This high root respiration rate was allowed by the high aeration capacity. The O(2) consumption-related traits of hydrophyte roots were closely correlated with N acquisition strategies, which consequently led to a compensational relationship with the root aeration capacity. It is likely that this functional linkage plays an important role as a core mechanism in the adaptation of plants to hypoxic soils. PMID:22575011

  11. Lung Parenchymal Mechanics

    PubMed Central

    Suki, Béla; Stamenovic, Dimitrije; Hubmayr, Rolf

    2014-01-01

    The lung parenchyma comprises a large number of thin-walled alveoli, forming an enormous surface area, which serves to maintain proper gas exchange. The alveoli are held open by the transpulmonary pressure, or prestress, which is balanced by tissues forces and alveolar surface film forces. Gas exchange efficiency is thus inextricably linked to three fundamental features of the lung: parenchymal architecture, prestress, and the mechanical properties of the parenchyma. The prestress is a key determinant of lung deformability that influences many phenomena including local ventilation, regional blood flow, tissue stiffness, smooth muscle contractility, and alveolar stability. The main pathway for stress transmission is through the extracellular matrix. Thus, the mechanical properties of the matrix play a key role both in lung function and biology. These mechanical properties in turn are determined by the constituents of the tissue, including elastin, collagen, and proteoglycans. In addition, the macroscopic mechanical properties are also influenced by the surface tension and, to some extent, the contractile state of the adherent cells. This article focuses on the biomechanical properties of the main constituents of the parenchyma in the presence of prestress and how these properties define normal function or change in disease. An integrated view of lung mechanics is presented and the utility of parenchymal mechanics at the bedside as well as its possible future role in lung physiology and medicine are discussed. PMID:23733644

  12. Lung parenchymal mechanics.

    PubMed

    Suki, Béla; Stamenović, Dimitrije; Hubmayr, Rolf

    2011-07-01

    The lung parenchyma comprises a large number of thin-walled alveoli, forming an enormous surface area, which serves to maintain proper gas exchange. The alveoli are held open by the transpulmonary pressure, or prestress, which is balanced by tissues forces and alveolar surface film forces. Gas exchange efficiency is thus inextricably linked to three fundamental features of the lung: parenchymal architecture, prestress, and the mechanical properties of the parenchyma. The prestress is a key determinant of lung deformability that influences many phenomena including local ventilation, regional blood flow, tissue stiffness, smooth muscle contractility, and alveolar stability. The main pathway for stress transmission is through the extracellular matrix. Thus, the mechanical properties of the matrix play a key role both in lung function and biology. These mechanical properties in turn are determined by the constituents of the tissue, including elastin, collagen, and proteoglycans. In addition, the macroscopic mechanical properties are also influenced by the surface tension and, to some extent, the contractile state of the adherent cells. This chapter focuses on the biomechanical properties of the main constituents of the parenchyma in the presence of prestress and how these properties define normal function or change in disease. An integrated view of lung mechanics is presented and the utility of parenchymal mechanics at the bedside as well as its possible future role in lung physiology and medicine are discussed. PMID:23733644

  13. Performance of organics and nitrogen removal in subsurface wastewater infiltration systems by intermittent aeration and shunt distributing wastewater.

    PubMed

    Pan, Jing; Yuan, Fang; Yu, Long; Huang, Linli; Fei, Hexin; Cheng, Fan; Zhang, Qi

    2016-07-01

    Organics and nitrogen removal in four subsurface wastewater infiltration systems (SWISs), named SWIS A (without intermittent aeration and shunt distributing wastewater), SWIS B (with intermittent aeration), SWIS C (with shunt distributing wastewater) and SWIS D (with intermittent aeration and shunt distributing wastewater) was investigated. High average removal rates of 92.3% for COD, 90.2% for NH4-N and 88.1% for TN were achieved simultaneously in SWIS D compared with SWIS A, B and C. The excellent TN removal of SWIS D was due to intermittent aeration provided sufficient oxygen for nitrification in upper matrix and the favorable anoxic or anaerobic environment for denitrification in subsequent matrix, and moreover, shunt distributing wastewater provided sufficient carbon source for denitrification process. The results indicated that intermittent artificial aeration combined with shunt distributing wastewater could achieve high organics and nitrogen removal in SWISs. PMID:27039353

  14. Nitrification cessation and recovery in an aerated saturated vertical subsurface flow treatment wetland: Field studies and microscale biofilm modeling.

    PubMed

    Murphy, Clodagh; Rajabzadeh, Amin R; Weber, Kela P; Nivala, Jaime; Wallace, Scott D; Cooper, David J

    2016-06-01

    In aerated treatment wetlands, oxygen availability is not a limiting factor in sustaining a high level of nitrification in wastewater treatment. In the case of an air blower failure, nitrification would cease, potentially causing adverse effects to the nitrifying bacteria. A field trial was completed investigating nitrification loss when aeration is switched off, and the system recovery rate after the aeration is switched back on. Loss of dissolved oxygen was observed to be more rapid than loss of nitrification. Nitrate was observed in the effluent long after the aeration was switched off (48h+). A complementary modeling study predicted nitrate diffusion out of biofilm over a 48h period. After two weeks of no aeration in the established system, nitrification recovered within two days, whereas nitrification establishment in a new system was previously observed to require 20-45days. These results suggest that once established resident nitrifying microbial communities are quite robust. PMID:26967335

  15. Lung Cancer

    MedlinePlus

    Lung cancer is one of the most common cancers in the world. It is a leading cause of cancer death in men and women in the United States. Cigarette smoking causes most lung cancers. The more cigarettes you smoke per day and ...

  16. Lung transplantation

    PubMed Central

    Afonso, José Eduardo; Werebe, Eduardo de Campos; Carraro, Rafael Medeiros; Teixeira, Ricardo Henrique de Oliveira Braga; Fernandes, Lucas Matos; Abdalla, Luis Gustavo; Samano, Marcos Naoyuki; Pêgo-Fernandes, Paulo Manuel

    2015-01-01

    ABSTRACT Lung transplantation is a globally accepted treatment for some advanced lung diseases, giving the recipients longer survival and better quality of life. Since the first transplant successfully performed in 1983, more than 40 thousand transplants have been performed worldwide. Of these, about seven hundred were in Brazil. However, survival of the transplant is less than desired, with a high mortality rate related to primary graft dysfunction, infection, and chronic graft dysfunction, particularly in the form of bronchiolitis obliterans syndrome. New technologies have been developed to improve the various stages of lung transplant. To increase the supply of lungs, ex vivo lung reconditioning has been used in some countries, including Brazil. For advanced life support in the perioperative period, extracorporeal membrane oxygenation and hemodynamic support equipment have been used as a bridge to transplant in critically ill patients on the waiting list, and to keep patients alive until resolution of the primary dysfunction after graft transplant. There are patients requiring lung transplant in Brazil who do not even come to the point of being referred to a transplant center because there are only seven such centers active in the country. It is urgent to create new centers capable of performing lung transplantation to provide patients with some advanced forms of lung disease a chance to live longer and with better quality of life. PMID:26154550

  17. Lung Diseases

    MedlinePlus

    When you breathe, your lungs take in oxygen from the air and deliver it to the bloodstream. The cells in your body need oxygen to ... you breathe nearly 25,000 times. People with lung disease have difficulty breathing. Millions of people in ...

  18. Collapsed lung (pneumothorax)

    MedlinePlus

    Air around the lung; Air outside the lung; Pneumothorax dropped lung; Spontaneous pneumothorax ... Collapsed lung can be caused by an injury to the lung. Injuries can include a gunshot or knife wound ...

  19. Lung disease - resources

    MedlinePlus

    Resources - lung disease ... The following organizations are good resources for information on lung disease : American Lung Association -- www.lung.org National Heart, Lung, and Blood Institute -- www.nhlbi.nih.gov ...

  20. EVALUATING THE COSTS OF PACKED-TOWER AERATION AND GAC FOR CONTROLLING SELECTED ORGANICS

    EPA Science Inventory

    This article focuses on a preliminary cost analysis that compares liquid-phase granular activated carbon (GAC) treatment with packed-tower aeration (PTA) treatment, with and without air emissions control. The sensitivity of cost to design and operating variables is also discussed...

  1. Processes to improve energy efficiency during pumping and aeration of recirculating water in circular tank systems

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Conventional gas transfer technologies for aquaculture systems occupy a large amount of space, require considerable capital investment, and can contribute to high electricity demand. In addition, diffused aeration in a circular tank can interfere with the hydrodynamics of water rotation and the spee...

  2. Use of a web-based model for aeration management in stored rough rice

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A web-based model was used to simulate the impact of aeration on population growth of the lesser grain borer, Rhyzopertha dominica (F.), and the rice weevil, Sitophilus oryzae (L.), in stored rough rice at Beaumont, TX, USA. Simulations were run for each of 10 years with 1 August as the start date, ...

  3. Gas transfer rates from airlifts used for concurrent aeration, carbon dioxide stripping, and recirculation

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Airlifts simplify recirculating aquaculture systems and can potentially reduce capital costs and minimize maintenance issues. Airlifts have the ability to move and aerate water as well as degass the water of any carbon dioxide. This study evaluated the oxygen transfer and carbon dioxide removal abil...

  4. Flow, aeration, and carbon dioxide transfer rates for airlifts used in recirculating aquaculture systems

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Airlift pumping systems reduce the electrical costs of moving water in a recirculating aquaculture system and can be concurrently designed to aerate water and remove carbon dioxide. This study determined the water flow, oxygen transfer, and CO2 removal rates for water using airlift technology in a 1...

  5. Improvement of anaerobic digester performance by wastewater recirculation through an aerated membrane.

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Swine wastewater from an anaerobic digester was recirculated through a silicone hose located in an external aeration chamber to determine its effect on wastewater malodorants and biogas composition. The silicone hose acted as a semipermeable membrane for the passage of small molecules. In the first...

  6. Evaluation of cost-effective aeration technology solutions to address total trihalomethane (TTHM) compliance

    EPA Science Inventory

    The primary objective of this project was to evaluate cost-effective aeration technology solutions to address TTHM compliance at a water treatment plant clearwell. The project team worked closely with EPA Region 6 and the EPA Office of Research and Development (ORD) to identify a...

  7. Combination of methoprene and controlled aeration to manage insects in stored wheat

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The insect growth regulator methoprene, in the commercial formulation Diacon II®, was applied to wheat stored in small bins either alone or in combination with controlled aeration of the bins to lower grain temperature for insect pest management of stored wheat. Grain temperatures and monitored and ...

  8. Effect of the aerated structure on selected properties of freeze-dried hydrocolloid gels

    NASA Astrophysics Data System (ADS)

    Ciurzyńska, Agnieszka; Lenart, Andrzej

    2016-01-01

    The ability to create diverse structures and studies on the effect of the aerated structure on selected properties with the use of freeze-dried gels may provide knowledge about the properties of dried foods. Such gels can be a basis for obtaining innovative food products. For the gel preparation, 3 types of hydrocolloids were used: low-methoxyl pectin, a mixture of xanthan gum and locust-bean gum, and a mixture of xanthan gum and guar gum. Gels were aerated for 3 and 7 min, frozen at a temperature of -45°C 2 h-1, and freeze-dried at a temperature of 30°C. For the samples obtained, structure, porosity, shrinkage, rehydration, and colour were investigated. It was shown that the type of the hydrocolloid and aeration time influence the structure of freeze-dried gels, which determines such properties of samples as porosity, shrinkage, density, rehydration, and colour. The bigger pores of low-methoxyl pectin gels undergo rehydration in the highest degree. The delicate and aerated structure of gels with the mixture of xanthan gum and locust-bean gum was damaged during freeze-drying and shrinkage exhibited the highest value. Small pores of samples with the mixture of xanthan gum and guar gum were responsible for the lower rehydration properties, but the highest porosity value contributed to the highest lightness value.

  9. Integral parameters for characterizing water, energy, and aeration properties of soilless plant growth media

    NASA Astrophysics Data System (ADS)

    Chamindu Deepagoda, T. K. K.; Chen Lopez, Jose Choc; Møldrup, Per; de Jonge, Lis Wollesen; Tuller, Markus

    2013-10-01

    Over the last decade there has been a significant shift in global agricultural practice. Because the rapid increase of human population poses unprecedented challenges to production of an adequate and economically feasible food supply for undernourished populations, soilless greenhouse production systems are regaining increased worldwide attention. The optimal control of water availability and aeration is an essential prerequisite to successfully operate plant growth systems with soilless substrates such as aggregated foamed glass, perlite, rockwool, coconut coir, or mixtures thereof. While there are considerable empirical and theoretical efforts devoted to characterize water retention and aeration substrate properties, a holistic, physically-based approach considering water retention and aeration concurrently is lacking. In this study, the previously developed concept of integral water storage and energy was expanded to dual-porosity substrates and an analog integral oxygen diffusivity parameter was introduced to simultaneously characterize aeration properties of four common soilless greenhouse growth media. Integral parameters were derived for greenhouse crops in general, as well as for tomatoes. The integral approach provided important insights for irrigation management and for potential optimization of substrate properties. Furthermore, an observed relationship between the integral parameters for water availability and oxygen diffusivity can be potentially applied for the design of advanced irrigation and management strategies to ensure stress-free growth conditions, while conserving water resources.

  10. 72. (Credit LSU) Aerator in settling basin south of McNeil ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    72. (Credit LSU) Aerator in settling basin south of McNeil Pumping Station c1907. (Louisiana State University in Shreveport Archives, post card collection) - McNeil Street Pumping Station, McNeil Street & Cross Bayou, Shreveport, Caddo Parish, LA

  11. Opportunities for energy conservation and demand-side management in pumping and aeration systems

    SciTech Connect

    Hoffman, H.L. )

    1992-12-01

    Of the electric energy supplied by electric utility companies in the United States, approximately 1 to 3% is consumed by water and wastewater utilities. power costs represent 20 to 35% of the budgets of water and wastewater utilities. The water utilities are the organizations that supply us with safe drinking water for residential, commercial, and industrial uses. The wastewater utilities convey the used water to a plant for wastewater treatment prior to discharge back into the environment (mostly rivers, bays, and coastal waters).This report should provide sufficient background information to assist the electric utility staff in efforts to: Analyze the efficiency of existing pumping and aeration systems; identify more energy efficient alternative pumping and aeration systems for possible modification and/or replacement of existing equipment; provide a framework for planning future pumping and aeration systems with a greater consideration of the electric energy impact of those facilities; identify more energy efficient operationsand control strategies to reduce the electric energy consumption and/or peak demand of existing pumping and aeration systems.

  12. In-situ groundwater aeration as an effective technique for remediation of petroleum-contaminated aquifers

    SciTech Connect

    Baker, B.W.; Hoffman, G.D. ); Gan, D.R. )

    1994-08-01

    Petroleum contamination of groundwater is a widespread occurrence and is traditionally remediated using groundwater extraction with surface treatment. This remediation scheme is ineffective due to irregular groundwater flow paths, and the low solubility and high soil sorption tendencies of petroleum products in the subsurface. In-situ groundwater aeration, sometimes referred to as air sparging, provides a more effective approach. In-situ groundwater aeration technology takes advantage of the high volatility and biodegradability of many health concerned petroleum constituents. By injecting air into the subsurface, volatile organic compounds readily partition into the vapor phase and are subsequently transported to the vadose zone for collection by a soil vapor extraction system. The system also provides sufficient amounts of oxygen to the groundwater to promote biodegradation of petroleum contaminants. Development of an in-situ groundwater aeration system for petroleum releases within a regulatory framework includes several steps. First, site specific fate and transport mechanisms relevant to petroleum releases must be evaluated. Next, key design parameters, such as injection well construction, well locations, and air injection rates are discussed. Approximate capital, operation, and maintenance costs are given along with typical system remedial time frames. A case history involving a gasoline release from an underground storage tank is presented to illustrate the development and success of an in-situ aeration system.

  13. Opportunities for energy conservation and demand-side management in pumping and aeration systems. Final report

    SciTech Connect

    Hoffman, H.L.

    1992-12-01

    Of the electric energy supplied by electric utility companies in the United States, approximately 1 to 3% is consumed by water and wastewater utilities. power costs represent 20 to 35% of the budgets of water and wastewater utilities. The water utilities are the organizations that supply us with safe drinking water for residential, commercial, and industrial uses. The wastewater utilities convey the used water to a plant for wastewater treatment prior to discharge back into the environment (mostly rivers, bays, and coastal waters).This report should provide sufficient background information to assist the electric utility staff in efforts to: Analyze the efficiency of existing pumping and aeration systems; identify more energy efficient alternative pumping and aeration systems for possible modification and/or replacement of existing equipment; provide a framework for planning future pumping and aeration systems with a greater consideration of the electric energy impact of those facilities; identify more energy efficient operationsand control strategies to reduce the electric energy consumption and/or peak demand of existing pumping and aeration systems.

  14. CONTROL OF VOLATILE ORGANIC CONTAMINANTS IN GROUNDWATER BY IN-WELL AERATION

    EPA Science Inventory

    At a 0.1 mgd well contaminated with several volatile organic compounds (VOCs), principally trichloroethylene (TCE), several in-well aeration schemes were evaluated as control technologies. The well was logged by the USGS to define possible zones of VOC entry. A straddle packer an...

  15. FIELD EVALUATION OF AERATION PROCESSES FOR ORGANIC CONTAMINANT REMOVAL FROM GROUNDWATER

    EPA Science Inventory

    The results of the pilot plant evaluation of aeration methods for the removal of volatile organic solvents from ground water are presented. The project took place at Glen Cove, Long Island, New York, where the concentration of cis-1,2-dichloroethyene, trichloroethylene, and tetra...

  16. SURVEY AND EVALUATION OF FINE BUBBLE DOME AND DISC DIFFUSER AERATION SYSTEMS IN NORTH AMERICA

    EPA Science Inventory

    The research project was undertaken with the overall objective of better defining the oxygen transfer performance, operation and maintenance (O and M) requirements, and proper design approaches for ceramic fine bubble dome and disc diffuser aeration systems used in activated slud...

  17. DEMONSTRATION BULLETIN: LOW TEMPERATURE THERMAL AERATION (LTTA®) SYSTEM - CANONIE ENVIRONMENTAL SERVICES, INC.

    EPA Science Inventory

    The Low Temperature Thermal Aeration (LTTA®) process was developed by Canonie Environmental Services, Inc. (Canonie), as a treatment system that desorbs organic contaminants from soils by heating the soils up to 800 °F. The main components of the LTTA process include the follow...

  18. Lung B-line artefacts and their use

    PubMed Central

    Mathis, Gebhard; Blaivas, Michael; Volpicelli, Giovanni; Seibel, Armin; Wastl, Daniel; Atkinson, Nathan S. S.; Cui, Xin-Wu; Fan, Mei; Yi, Dong

    2016-01-01

    Background The analysis of lung artefacts has gained increasing importance as markers of lung pathology. B-line artefact (BLA), caused by a reverberation phenomenon, is the most important lung artefact. In this review, we discuss the current role of BLA in pneumology and explore open questions of the published consensus. Methods We summarized current literature about BLA. Also, we presented observations on healthy subjects and patients with interstitial syndrome (pulmonary fibrosis and edema), to investigate technical factors influencing BLA visualization. Results BLA imaging is influenced by more factors than recently assumed. When multiple BLA is visualized in the lung, they represent a sign of increased density due to the loss of aeration in the lung periphery. This condition may indicate different diseases including cardiogenic pulmonary edema, diffuse or focal interstitial lung diseases (ILD), infections and acute respiratory distress syndrome (ARDS). Correct interpretation of BLA in lung ultrasound is strongly influenced by associated sonographic signs and careful integration of all relevant clinical information. Conclusions BLA is useful to monitor clinical response, and may become crucial in directing the diagnostic process. Further research is warranted to clarify technical adjustments, different probe and machine factors that influence the visualization of BLA. PMID:27293860

  19. Optimization of micro-aeration intensity in acidogenic reactor of a two-phase anaerobic digester treating food waste

    SciTech Connect

    Xu, Suyun; Selvam, Ammaiyappan; Wong, Jonathan W.C.

    2014-02-15

    Highlights: • Effect of micro-aeration on acidogenesis and hydrolysis of food waste was investigated. • Micro-aeration at 258 L-air/kg TS/d increased the VFAs production 3-fold. • High aeration leads to loss of substrate through microbial biomass and respiration. • Optimum aeration increased methane recovery while high aeration intensity reduced methane yield. - Abstract: Micro-aeration is known to promote the activities of hydrolytic exo-enzymes and used as a strategy to improve the hydrolysis of particulate substrate. The effect of different micro-aeration rates, 0, 129, 258, and 387 L-air/kg TS/d (denoted as LBR-AN, LBR-6h, LBR-3h and LBR-2h, respectively) on the solubilization of food waste was evaluated at 35 °C in four leach bed reactors (LBR) coupled with methanogenic upflow anaerobic sludge blanket (UASB) reactor. Results indicate that the intensity of micro-aeration influenced the hydrolysis and methane yield. Adequate micro-aeration intensity in LBR-3h and LBR-2h significantly enhanced the carbohydrate and protein hydrolysis by 21–27% and 38–64% respectively. Due to the accelerated acidogenesis, more than 3-fold of acetic acid and butyric acid were produced in LBR-3h as compared to the anaerobic treatment LBR-AN resulting in the maximum methane yield of 0.27 L CH{sub 4}/g VS{sub added} in the UASB. The performance of LBR-6h with inadequate aeration was similar to that of LBR-AN with a comparable hydrolysis degree. Nevertheless, higher aeration intensity in LBR-2h was also unfavorable for methane yield due to significant biomass generation and CO{sub 2} respiration of up to 18.5% and 32.8% of the total soluble hydrolysate, respectively. To conclude, appropriate micro-aeration rate can promote the hydrolysis of solid organic waste and methane yield without undesirable carbon loss and an aeration intensity of 258 L-air/kg TS/d is recommended for acidogenic LBR treating food waste.

  20. Impact of intermittent aerations on leachate quality and greenhouse gas reduction in the aerobic-anaerobic landfill method.

    PubMed

    Nag, Mitali; Shimaoka, Takayuki; Komiya, Teppei

    2016-09-01

    The aerobic-anaerobic landfill method (AALM) is a novel approach in solid waste management that could shorten the landfill post-closure period and minimize the environmental loads. In this study, the aerobic-anaerobic landfill method was evaluated by using intermittent aeration. In addition, the nitrification-denitrification process was assessed as a means of reducing the emission of greenhouse gases (GHGs) and improving the leachate quality during the degradation of the organic solid waste. The leachate quality and the gas composition in each of the reactors were measured during the experimental period (408days). The aeration process entailed the injection of air into plexiglass cylinders (200cm height×10 cm diameter), filled with fresh organic solid waste collected from a composting plant. Different aeration routines were applied, namely, continuous aeration (aerobic reactor A), aeration for three days/week (aerobic-anaerobic reactor B), aeration for 6h/day (aerobic-anaerobic reactor C), and no aeration (non-aerated reactor D). It was found that aerobic reactor A produced the best results in terms of reduction of GHGs and improvement of the leachate quality. The aerobic-anaerobic reactor C was found to be more effective than reactor B in respect of both the emission of GHGs and the leachate quality; moreover, compared with aerobic reactor A, energy costs were reduced by operating this reactor. The transition period phenomenon was investigated during an intensive seven-day experiment conducted on the discharged leachate obtained from aerobic-anaerobic reactors B and C. The experiment concerned the differences in the composition of the gas during the aeration and the non-aeration periods. It was found that the transition period between the aeration and non-aeration cycles, which followed the simultaneous nitrification-denitrification had a considerable effect on the leachate quality of both the reactors. The results indicated that AALM has the potential to reduce

  1. Dynamic measures of regional lung air volume using phase contrast x-ray imaging

    NASA Astrophysics Data System (ADS)

    Kitchen, M. J.; Lewis, R. A.; Morgan, M. J.; Wallace, M. J.; Siew, M. L.; Siu, K. K. W.; Habib, A.; Fouras, A.; Yagi, N.; Uesugi, K.; Hooper, S. B.

    2008-11-01

    Phase contrast x-ray imaging can provide detailed images of lung morphology with sufficient spatial resolution to observe the terminal airways (alveoli). We demonstrate that quantitative functional and anatomical imaging of lung ventilation can be achieved in vivo using two-dimensional phase contrast x-ray images with high contrast and spatial resolution (<100 µm) in near real time. Changes in lung air volume as small as 25 µL were calculated from the images of term and preterm rabbit pup lungs (n = 28) using a single-image phase retrieval algorithm. Comparisons with plethysmography and computed tomography showed that the technique provided an accurate and robust method of measuring total lung air volumes. Furthermore, regional ventilation was measured by partitioning the phase contrast images, which revealed differences in aeration for different ventilation strategies.

  2. Measurement of absolute regional lung air volumes from near-field x-ray speckles.

    PubMed

    Leong, Andrew F T; Paganin, David M; Hooper, Stuart B; Siew, Melissa L; Kitchen, Marcus J

    2013-11-18

    Propagation-based phase contrast x-ray (PBX) imaging yields high contrast images of the lung where airways that overlap in projection coherently scatter the x-rays, giving rise to a speckled intensity due to interference effects. Our previous works have shown that total and regional changes in lung air volumes can be accurately measured from two-dimensional (2D) absorption or phase contrast images when the subject is immersed in a water-filled container. In this paper we demonstrate how the phase contrast speckle patterns can be used to directly measure absolute regional lung air volumes from 2D PBX images without the need for a water-filled container. We justify this technique analytically and via simulation using the transport-of-intensity equation and calibrate the technique using our existing methods for measuring lung air volume. Finally, we show the full capabilities of this technique for measuring regional differences in lung aeration. PMID:24514306

  3. "Synthetic" comets: a new look at lung sonography.

    PubMed

    Soldati, Gino; Giunta, Valeria; Sher, Sara; Melosi, Francesca; Dini, Claudia

    2011-11-01

    Ultrasound interstitial syndrome is an echographic pattern of the lung characterized by the presence of multiple acoustic artifacts called "comets" or B-lines. It correlates to increase in extravascular lung water and to interstitial lung disease. From the physical and genetic point of view, the characteristics and the entity of this correlation have not yet been studied. The purpose of this study was to extrapolate past observations and demonstrate how comets or B-lines are artifactual images whose formation is linked to ultrasound interactions on discretely aerated tissues of variable density. Echographic comets were studied by scanning a wet synthetic, partially aerated polyurethane sponge (phantom). Density of the phantom in different drying phases was measured and correlated to the presence of echographic artifacts. Artifacts (comets) showed a different concentration from a completely white artifactual field to presence of rare comets. Their density correlates with porosity and geometry of the phantom. In our opinion, comets represent superficial, artifactual, density and geometry correlated phenomenon due to the acoustic permeability of a broken (collapsed) specular reflector, normally present when the phantom is dry. PMID:21924815

  4. Combination of Methoprene and Controlled Aeration to Manage Insects in Stored Wheat.

    PubMed

    Liu, Samuel S; Arthur, Frank H; VanGundy, Douglas; Phillips, Thomas W

    2016-01-01

    A commercial formulation of the insect growth regulator methoprene was applied to wheat stored in small bins either alone or in combination with controlled aeration of the bins, to lower grain temperature for insect pest management of stored wheat. Grain temperatures were monitored and modified by a computer-controlled thermocouple system that also activated the aeration system at programmed set-points to move cool ambient air through the grain mass to lower grain temperature. Results from sampling insect populations in experimental storage bins along with laboratory mortality bioassays of insects placed on wheat taken from the bins over the course of the storage period showed that methoprene was very effective in controlling infestation by the externally-feeding stored grain insects Plodia interpunctella (Hübner), the Indian meal moth Tribolium castaneum (Herbst), the red flour beetle, Cryptolestes ferrugineus (Stephens), the rusty grain beetle, and also for the internal-feeding pest Rhyzopertha dominica( Fauvel), the lesser grain borer. Methoprene did not give good control of the internal-feeding pest Sitophilus oryzae (L.), the rice weevil. Aeration alone was somewhat effective in suppressing insect population development, while methoprene alone or when combined with aeration greatly enhanced insect control. Commercial grain grading for industry quality standards at the end of the storage period confirmed the impact of insect suppression on maintaining high quality of the stored wheat. This field experiment shows that methoprene combined with aeration to cool grain can be effective for pest management of stored wheat in the southern plains of the United States of America. PMID:27322331

  5. [Effect of Aeration Strategies on Emissions of Nitrogenous Gases and Methane During Sludge Bio-Drying].

    PubMed

    Qi, Lu; Wei, Yuan-song; Zhang, Jun-ya; Zhao, Chen-yang; Cai, Xing; Zhang, Yuan-li; Shao, Chun-yan; Li, Hong-mei

    2016-01-15

    The data on nitrogen gas (NH3, N2O, NO) emissions during sludge bio-drying process in China is scarce, especially NO due to its unstable chemical property. In this study, effect of two aeration modes on emissions of methane and nitrogenous gas was compared during the continuous aerated turning pile sludge bio-drying process at full scale. In these two aeration strategies, the one currently used in the plant was set as the control, and the other was set as the test in which the aeration was used for oxygen supply, pile temperature control, and moisture removal in the start-up, middle and final stages, respectively. The results showed that the aeration strategy used in the test could not only obviously accelerate the rate of sludge drying (the moisture contents of the test and the control were 36.6% and 42% on day 11) , but also had a better drying performance (the final moisture contents of the test and the control were 33.6% and 37.6%, respectively) and decreased the ammonia cumulative emission by 5%, (ammonia cumulative emission of the test and the control were 208 mg x m(-3) and 219.8 mg x m(-3), respectively). Though a lower accumulated emission (eCO2) of greenhouse gas in the test at 3.61 kg x t(-1) was observed than that of the control (3.73 kg x t(-1) dry weight) , the cumulative emission of NO in the test at 1.9 g x m(-2) was 15. 9% higher than that of the control (1.6 g x m(-2)). PMID:27078979

  6. Lipid accumulation and CO2 utilization of Nannochloropsis oculata in response to CO2 aeration.

    PubMed

    Chiu, Sheng-Yi; Kao, Chien-Ya; Tsai, Ming-Ta; Ong, Seow-Chin; Chen, Chiun-Hsun; Lin, Chih-Sheng

    2009-01-01

    In order to produce microalgal lipids that can be transformed to biodiesel fuel, effects of concentration of CO(2) aeration on the biomass production and lipid accumulation of Nannochloropsis oculata in a semicontinuous culture were investigated in this study. Lipid content of N. oculata cells at different growth phases was also explored. The results showed that the lipid accumulation from logarithmic phase to stationary phase of N. oculata NCTU-3 was significantly increased from 30.8% to 50.4%. In the microalgal cultures aerated with 2%, 5%, 10% and 15% CO(2), the maximal biomass and lipid productivity in the semicontinuous system were 0.480 and 0.142 g L(-1)d(-1) with 2% CO(2) aeration, respectively. Even the N. oculata NCTU-3 cultured in the semicontinuous system aerated with 15% CO(2), the biomass and lipid productivity could reach to 0.372 and 0.084 g L(-1)d(-1), respectively. In the comparison of productive efficiencies, the semicontinuous system was operated with two culture approaches over 12d. The biomass and lipid productivity of N. oculata NCTU-3 were 0.497 and 0.151 g L(-1)d(-1) in one-day replacement (half broth was replaced each day), and were 0.296 and 0.121 g L(-1)d(-1) in three-day replacement (three fifth broth was replaced every 3d), respectively. To optimize the condition for long-term biomass and lipid yield from N. oculata NCTU-3, this microalga was suggested to grow in the semicontinuous system aerated with 2% CO(2) and operated by one-day replacement. PMID:18722767

  7. Combination of Methoprene and Controlled Aeration to Manage Insects in Stored Wheat

    PubMed Central

    Liu, Samuel S.; Arthur, Frank H.; VanGundy, Douglas; Phillips, Thomas W.

    2016-01-01

    A commercial formulation of the insect growth regulator methoprene was applied to wheat stored in small bins either alone or in combination with controlled aeration of the bins, to lower grain temperature for insect pest management of stored wheat. Grain temperatures were monitored and modified by a computer-controlled thermocouple system that also activated the aeration system at programmed set-points to move cool ambient air through the grain mass to lower grain temperature. Results from sampling insect populations in experimental storage bins along with laboratory mortality bioassays of insects placed on wheat taken from the bins over the course of the storage period showed that methoprene was very effective in controlling infestation by the externally-feeding stored grain insects Plodia interpunctella (Hübner), the Indian meal moth Tribolium castaneum (Herbst), the red flour beetle, Cryptolestes ferrugineus (Stephens), the rusty grain beetle, and also for the internal-feeding pest Rhyzopertha dominica( Fauvel), the lesser grain borer. Methoprene did not give good control of the internal-feeding pest Sitophilus oryzae (L.), the rice weevil. Aeration alone was somewhat effective in suppressing insect population development, while methoprene alone or when combined with aeration greatly enhanced insect control. Commercial grain grading for industry quality standards at the end of the storage period confirmed the impact of insect suppression on maintaining high quality of the stored wheat. This field experiment shows that methoprene combined with aeration to cool grain can be effective for pest management of stored wheat in the southern plains of the United States of America. PMID:27322331

  8. Oxygen demand for the stabilization of the organic fraction of municipal solid waste in passively aerated bioreactors.

    PubMed

    Kasinski, Slawomir; Wojnowska-Baryla, Irena

    2014-02-01

    Conventional aerobic waste treatment technologies require the use of aeration devices that actively transport air through the stabilized waste mass, which greatly increases operating costs. In addition, improperly operated active aeration systems, may have the adverse effect of cooling the stabilized biomass. Because active aeration can be a limiting factor for the stabilization process, passive aeration can be equally effective and less expensive. Unfortunately, there are few reports documenting the use of passive aeration systems in municipal waste stabilization. There have been doubts raised as to whether a passive aeration system provides enough oxygen to the organic matter mineralization processes. In this paper, the effectiveness of aeration during aerobic stabilization of four different organic fractions of municipal waste in a reactor with an integrated passive ventilation system and leachate recirculation was analyzed. For the study, four fractions separated by a rotary screen were chosen. Despite the high temperatures in the reactor, the air flow rate was below 0.016 m(3)/h. Using Darcy's equation, theoretical values of the air flow rate were estimated, depending on the intensity of microbial metabolism and the amount of oxygen required for the oxidation of organic compounds. Calculations showed that the volume of supplied air exceeded the microorganisms demand for oxidation and endogenous activity by 1.7-2.88-fold. PMID:24268917

  9. Intensified organics and nitrogen removal in the intermittent-aerated constructed wetland using a novel sludge-ceramsite as substrate.

    PubMed

    Wu, Haiming; Fan, Jinlin; Zhang, Jian; Ngo, Huu Hao; Guo, Wenshan; Liang, Shuang; Lv, Jialong; Lu, Shaoyong; Wu, Weizhong; Wu, Suqing

    2016-06-01

    In this study, a novel sludge-ceramsite was applied as main substrate in intermittent-aerated subsurface flow constructed wetlands (SSF CWs) for treating decentralized domestic wastewater, and intensified organics and nitrogen removal in different SSF CWs (with and without intermittent aeration, with and without sludge-ceramsite substrate) were evaluated. High removal of 97.2% COD, 98.9% NH4(+)-N and 85.8% TN were obtained simultaneously in the intermittent-aerated CW system using sludge-ceramsite substrate compared with non-aerated CWs. Moreover, results from fluorescence in situ hybridization (FISH) analysis revealed that the growth of ammonia-oxidizing bacteria (AOB) and nitrite-oxidizing bacteria (NOB) in the intermittent-aerated CW system with sludge-ceramsite substrate was enhanced, thus indicating that the application of intermittent aeration and sludge-ceramsite plays an important role in nitrogen transformations. These results suggest that a combination of intermittent aeration and sludge-ceramsite substrate is reliable to enhance the treatment performance in SSF CWs. PMID:26832393

  10. Removal of organic pollutants from oak leachate in pilot scale wetland systems: How efficient are aeration and vegetation treatments?

    PubMed

    Svensson, Henric; Ekstam, Börje; Marques, Marcia; Hogland, William

    2015-11-01

    This study investigated the effects of aeration and/or vegetation in experimental constructed wetlands (CWs) as mesocosms on the removal of pollutants in oak wood leachate. Twelve outdoor wetland mesocosms, with randomized replicated treatment combinations of vegetation (Phragmites australis) and aeration was monitored during the second and third year after construction. The investigation included control tanks with no aeration and no vegetation. The parameters monitored were polyphenols (PPs), chemical oxygen demand (COD) and water colour. The reduction of COD after 28 days was approx. 50% and more than 50% of PPs, whereas only 40% of the water colour was removed. Aeration increased the effect of both COD and PP removal. The vegetation treatment had a small but significant effect on removal of COD. The vegetation + aeration treatment, as well as aeration alone, increased the removal efficiency of COD from 9.5 g m(-3) d(-1) in the control to 11 g m(-3) d(-1). The results suggest that CWs can be used to treat stormwater contaminated by oak wood leachate. Further, it is suggested that the main processes for removal of pollutants in the leachate occur in the open-water habitat and that the hydraulic retention time is more important for removal than aeration and vegetation related processes. PMID:26218465

  11. Oxygen demand for the stabilization of the organic fraction of municipal solid waste in passively aerated bioreactors

    SciTech Connect

    Kasinski, Slawomir Wojnowska-Baryla, Irena

    2014-02-15

    Highlights: • The use of an passively aerated reactor enables effective stabilization of OFMSW. • Convective air flow does not inhibit the aerobic stabilization of waste. • The use of an passively aerated reactor reduces the heat loss due to convection. • The volume of supplied air exceeds 1.7–2.88 times the microorganisms demand. - Abstract: Conventional aerobic waste treatment technologies require the use of aeration devices that actively transport air through the stabilized waste mass, which greatly increases operating costs. In addition, improperly operated active aeration systems, may have the adverse effect of cooling the stabilized biomass. Because active aeration can be a limiting factor for the stabilization process, passive aeration can be equally effective and less expensive. Unfortunately, there are few reports documenting the use of passive aeration systems in municipal waste stabilization. There have been doubts raised as to whether a passive aeration system provides enough oxygen to the organic matter mineralization processes. In this paper, the effectiveness of aeration during aerobic stabilization of four different organic fractions of municipal waste in a reactor with an integrated passive ventilation system and leachate recirculation was analyzed. For the study, four fractions separated by a rotary screen were chosen. Despite the high temperatures in the reactor, the air flow rate was below 0.016 m{sup 3}/h. Using Darcy’s equation, theoretical values of the air flow rate were estimated, depending on the intensity of microbial metabolism and the amount of oxygen required for the oxidation of organic compounds. Calculations showed that the volume of supplied air exceeded the microorganisms demand for oxidation and endogenous activity by 1.7–2.88-fold.

  12. Lung transplantation

    PubMed Central

    2013-01-01

    Lung transplantation may be the only intervention that can prolong survival and improve quality of life for those individuals with advanced lung disease who are acceptable candidates for the procedure. However, these candidates may be extremely ill and require ventilator and/or circulatory support as a bridge to transplantation, and lung transplantation recipients are at risk of numerous post-transplant complications that include surgical complications, primary graft dysfunction, acute rejection, opportunistic infection, and chronic lung allograft dysfunction (CLAD), which may be caused by chronic rejection. Many advances in pre- and post-transplant management have led to improved outcomes over the past decade. These include the creation of sound guidelines for candidate selection, improved surgical techniques, advances in donor lung preservation, an improving ability to suppress and treat allograft rejection, the development of prophylaxis protocols to decrease the incidence of opportunistic infection, more effective therapies for treating infectious complications, and the development of novel therapies to treat and manage CLAD. A major obstacle to prolonged survival beyond the early post-operative time period is the development of bronchiolitis obliterans syndrome (BOS), which is the most common form of CLAD. This manuscript discusses recent and evolving advances in the field of lung transplantation. PMID:23710330

  13. Sustained lung inflation at birth: what do we know, and what do we need to know?

    PubMed

    McCall, Karen E; Davis, Peter G; Owen, Louise S; Tingay, David G

    2016-03-01

    A sustained inflation has been advocated as a potential method of augmenting lung aeration at birth. Clinical trials have suggested that a sustained inflation may lead to a reduced need for intubation and ventilation in the first few days of life, without cardiovascular compromise or increased lung injury. Despite this, a sustained inflation is not currently a standard of practice, mainly due to a lack of clarity regarding the optimal delivery method. Animal trials have sought to refine delivery techniques. This review will outline current recommendations regarding a sustained inflation, discuss potential strategies for its optimal delivery and suggest priorities for future research. PMID:26527635

  14. Ammonia-based intermittent aeration control optimized for efficient nitrogen removal.

    PubMed

    Regmi, Pusker; Bunce, Ryder; Miller, Mark W; Park, Hongkeun; Chandran, Kartik; Wett, Bernhard; Murthy, Sudhir; Bott, Charles B

    2015-10-01

    This work describes the development of an intermittently aerated pilot-scale process (V = 0.45 m(3) ) operated for optimized efficient nitrogen removal in terms of volume, supplemental carbon and alkalinity requirements. The intermittent aeration pattern was controlled using a strategy based on effluent ammonia concentration set-points. The unique feature of the ammonia-based aeration control was that a fixed dissolved oxygen (DO) set-point was used and the length of the aerobic and anoxic time (anoxic time ≥25% of total cycle time) were changed based on the effluent ammonia concentration. Unlike continuously aerated ammonia-based aeration control strategies, this approach offered control over the aerobic solids retention time (SRT) to deal with fluctuating ammonia loading without solely relying on changes to the total SRT. This approach allowed the system to be operated at a total SRT with a small safety factor. The benefits of operating at an aggressive SRT were reduced hydraulic retention time (HRT) for nitrogen removal. As a result of such an operation, nitrite oxidizing bacteria (NOB) out-selection was also obtained (ammonia oxidizing bacteria [AOB] maximum activity: 400 ± 79 mgN/L/d, NOB maximum activity: 257 ± 133 mgN/L/d, P < 0.001) expanding opportunities for short-cut nitrogen removal. The pilot demonstrated a total inorganic nitrogen (TIN) removal rate of 95 ± 30 mgN/L/d at an influent chemical oxygen demand: ammonia (COD/NH4 (+) -N) ratio of 10.2 ± 2.2 at 25°C within the hydraulic retention time (HRT) of 4 h and within a total SRT of 5-10 days. The TIN removal efficiency up to 91% was observed during the study, while effluent TIN was 9.6 ± 4.4 mgN/L. Therefore, this pilot-scale study demonstrates that application of the proposed on-line aeration control is capable of relatively high nitrogen removal without supplemental carbon and alkalinity addition at a low HRT. PMID:26058705

  15. Optimized aeration strategies for nitrogen and phosphorus removal with aerobic granular sludge.

    PubMed

    Lochmatter, Samuel; Gonzalez-Gil, Graciela; Holliger, Christof

    2013-10-15

    Biological wastewater treatment by aerobic granular sludge biofilms offers the possibility to combine carbon (COD), nitrogen (N) and phosphorus (P) removal in a single reactor. Since denitrification can be affected by suboptimal dissolved oxygen concentrations (DO) and limited availability of COD, different aeration strategies and COD loads were tested to improve N- and P-removal in granular sludge systems. Aeration strategies promoting alternating nitrification and denitrification (AND) were studied to improve reactor efficiencies in comparison with more classical simultaneous nitrification-denitrification (SND) strategies. With nutrient loading rates of 1.6 gCOD L(-1) d(-1), 0.2 gN L(-1) d(-1), and 0.08 gP L(-1) d(-1), and SND aeration strategies, N-removal was limited to 62.3 ± 3.4%. Higher COD loads markedly improved N-removal showing that denitrification was limited by COD. AND strategies were more efficient than SND strategies. Alternating high and low DO phases during the aeration phase increased N-removal to 71.2 ± 5.6% with a COD loading rate of 1.6 gCOD L(-1) d(-1). Periods of low DO were presumably favorable to denitrifying P-removal saving COD necessary for heterotrophic N-removal. Intermittent aeration with anoxic periods without mixing between the aeration pulses was even more favorable to N-removal, resulting in 78.3 ± 2.9% N-removal with the lowest COD loading rate tested. P-removal was under all tested conditions between 88 and 98%, and was negatively correlated with the concentration of nitrite and nitrate in the effluent (r = -0.74, p < 0.01). With low COD loading rates, important emissions of undesired N2O gas were observed and a total of 7-9% of N left the reactor as N2O. However, N2O emissions significantly decreased with higher COD loads under AND conditions. PMID:23948562

  16. Lung transplantation in the rat. III. Functional studies in iso- and allografts

    SciTech Connect

    Marck, K.W.; Prop, J.; Wildevuur, C.R.

    1983-08-01

    Recently a microsurgical technique for orthotopic left lung transplantation in the rat was developed. The aim of this study was to investigate the influence of the operation itself and of an unmodified rejection reaction on the function of the transplanted rat lung. Orthotopic left lung transplantation was performed in 59 rats (34 isografts and 25 allografts). Isografts demonstrated a mean left lung perfusion of 23.1% in the first two postoperative weeks. Seven out of the 10 animals, subjected to a repeated scintigraphy 5-10 weeks later, had an increased graft perfusion, resulting in an almost normal mean left lung perfusion of 34.8%. At that time chest roentgenography revealed a good aeration of the grafts, that at autopsy had a normal aspect. Allografts showed an initial mean left lung perfusion (24.6%) similar to the isografts, which, however, declined sharply a few days later (4.3%). At that time chest roentgenography revealed totally opalescent grafts that at autopsy had the hepatized aspect characteristic of lung allograft rejection. These results of isogeneic and allogeneic lung transplantation in the rat were comparable with those of canine auto- and allotransplantation. For immunogenetic and economical reasons lung transplantation in the rat is a good alternative animal model in lung transplantation research.

  17. Rheumatoid lung disease

    MedlinePlus

    Lung disease - rheumatoid arthritis; Rheumatoid nodules; Rheumatoid lung ... Lung problems are common in rheumatoid arthritis. They often cause no symptoms. The cause of lung disease associated with rheumatoid arthritis is unknown. Sometimes, the medicines used to ...

  18. Lung cancer - small cell

    MedlinePlus

    Cancer - lung - small cell; Small cell lung cancer; SCLC ... About 15% of all lung cancer cases are SCLC. Small cell lung cancer is slightly more common in men than women. Almost all cases of SCLC ...

  19. Lung cancer - small cell

    MedlinePlus

    Cancer - lung - small cell; Small cell lung cancer; SCLC ... About 15% of all lung cancer cases are SCLC. Small cell lung cancer is slightly more common in men than women. Almost all cases of SCLC are ...

  20. Interstitial Lung Diseases

    MedlinePlus

    Interstitial lung disease is the name for a large group of diseases that inflame or scar the lungs. The inflammation and ... is responsible for some types of interstitial lung diseases. Specific types include Black lung disease among coal ...

  1. Effects of soil aeration, legume residue, and soil texture on transformations of macro- and micronutrients in soils. [Vicia villosa

    SciTech Connect

    Walters, D.T.; Doran, J.W. ); Aulakh, M.S. )

    1992-02-01

    Soil aeration is an important factor controlling microbial activity, nutrient availability, and plant root growth. The authors investigated the effect of hairy vetch (Vicia villosa) addition to well aerated (60% water-filled pore space (WFPS)) and poorly aerated (90% WFPS) soils of varying texture on transformations of C, N, P, K, Ca, Mg, S, Zn, Mn, Fe, and Cu for a 30-d period. The results of this study imply that incorporation of easily decomposable residue may supply substantial amounts of nutrients to growing plants. Where soils remain wet for > 10 d, residues may create intensive reducing conditions and a several fold increase in available Fe, Mn, Cu, and P. Conversely, DTPA extractable Fe, Mn, and Cu can vary greatly within a few weeks depending on soil aeration status, residue management, time of sampling, and soil texture and may lead to erroneous indices of nutrient availability to plants.

  2. Tsunami lung.

    PubMed

    Inoue, Yoshihiro; Fujino, Yasuhisa; Onodera, Makoto; Kikuchi, Satoshi; Shozushima, Tatsuyori; Ogino, Nobuyoshi; Mori, Kiyoshi; Oikawa, Hirotaka; Koeda, Yorihiko; Ueda, Hironobu; Takahashi, Tomohiro; Terui, Katsutoshi; Nakadate, Toshihide; Aoki, Hidehiko; Endo, Shigeatsu

    2012-04-01

    We encountered three cases of lung disorders caused by drowning in the recent large tsunami that struck following the Great East Japan Earthquake. All three were females, and two of them were old elderly. All segments of both lungs were involved in all the three patients, necessitating ICU admission and endotracheal intubation and mechanical ventilation. All three died within 3 weeks. In at least two cases, misswallowing of oil was suspected from the features noted at the time of the detection. Sputum culture for bacteria yielded isolation of Stenotrophomonas maltophilia, Legionella pneumophila, Burkholderia cepacia, and Pseudomonas aeruginosa. The cause of tsunami lung may be a combination of chemical induced pneumonia and bacterial pneumonia. PMID:22057370

  3. Respiratory inhibitors and uncouplers prevent the aeration-induced increase in mitochondrial anion conductivity.

    PubMed Central

    Halle-Smith, S C; Selwyn, M J

    1990-01-01

    1. When mitochondria are stirred in air the rate of anion conductivity increases, this effect being enhanced by the addition of respiratory substrate. 2. This effect is reversible if the mitochondria are stored for a period of time under N2. 3. The aeration-induced increase in mitochondrial anion conductivity can also be prevented by the addition of respiratory inhibitors rotenone and antimycin A, as well as by 30 microM-cyanide. 4. A decrease in this aeration-induced anion conductivity can also be observed upon the addition of the uncouplers carbonyl cyanide p-(trifluoromethoxy)phenylhydrazone (2 microM) and 2,4-dinitrophenol (100 microM). 5. Simultaneous measurements of mitochondrial anion conductivity and membrane potential show a relationship between the level of membrane potential and anion conductivity. 6. It is suggested that the level of membrane potential is either directly or indirectly responsible for the level of mitochondrial anion conductivity. PMID:2327957

  4. Respiratory inhibitors and uncouplers prevent the aeration-induced increase in mitochondrial anion conductivity.

    PubMed

    Halle-Smith, S C; Selwyn, M J

    1990-03-15

    1. When mitochondria are stirred in air the rate of anion conductivity increases, this effect being enhanced by the addition of respiratory substrate. 2. This effect is reversible if the mitochondria are stored for a period of time under N2. 3. The aeration-induced increase in mitochondrial anion conductivity can also be prevented by the addition of respiratory inhibitors rotenone and antimycin A, as well as by 30 microM-cyanide. 4. A decrease in this aeration-induced anion conductivity can also be observed upon the addition of the uncouplers carbonyl cyanide p-(trifluoromethoxy)phenylhydrazone (2 microM) and 2,4-dinitrophenol (100 microM). 5. Simultaneous measurements of mitochondrial anion conductivity and membrane potential show a relationship between the level of membrane potential and anion conductivity. 6. It is suggested that the level of membrane potential is either directly or indirectly responsible for the level of mitochondrial anion conductivity. PMID:2327957

  5. Design of passively aerated compost piles: Vertical air velocities between the pipes

    SciTech Connect

    Lynch, N.J.; Cherry, R.S.

    1996-09-01

    Passively aerated compost piles are built on a base of porous materials, such as straw or wood chips, in which perforated air supply pipes are distributed. The piles are not turned during composting, nor is forced-aeration equipment used, which significantly reduces the operating and capital expenses associated with these piles. Currently, pile configurations and materials are worked out by trial and error. Fundamentally based design procedures are difficult to develop because the natural convection air flow rate is not explicitly known, but rather is closely coupled with the pile temperature. This paper develops a mathematical model to analytically determine the maximum upward air flow velocity over an air supply pipe and the drop in vertical velocity away from the pipe. This model has one dimensionless number, dependent on the pile and base properties, which fully characterizes the velocity profile between the pipes. 9 refs., 4 figs., 1 tab.

  6. Optimization of Energy Consumption and Mass Transfer Parameters in a Surface Aeration Vessel.

    PubMed

    Mohammadpour, A; AkhavanBehabadi, M A; Ebrahimzadeh, M; Raisee, M; MajdiNasab, A R; Nosrati, M; Mousavi, S M

    2016-04-01

    This paper reports tests on a lab-scale surface aeration vessel was equipped with a Rushton turbine to examine its performance in terms of standard aeration efficiency (SAE), mixing time, and void fraction characteristics. These characteristics were investigated by tests using variations of rotor speed, impeller immersion depth, and water level. Results showed that variation of impeller immersion depth had a greater effect on the SAE compared to variation of water level. Moreover, the SAE increased with rotor speeds up to about 150 to 200 rpm and then decreased. In addition, void fraction improved by impeller immersion depth and rotor speed enhancement; however, mixing time and power number were reduced as rotor speed increased. According to the response surface methodology statistical optimizations, optimum values for rotor speed, impeller immersion depth, and water level were 168.90 rpm, 25 mm, and 30 cm, respectively, to achieve the maximum value of SAE. PMID:27131059

  7. Relationship between respiratory quotient, nitrification, and nitrous oxide emissions in a forced aerated composting process.

    PubMed

    Tsutsui, Hirofumi; Fujiwara, Taku; Inoue, Daisuke; Ito, Ryusei; Matsukawa, Kazutsugu; Funamizu, Naoyuki

    2015-08-01

    We assessed the relationship between respiratory quotient (RQ) and nitrification and nitrous oxide (N2O) emission in forced aerated composting using lab-scale reactors. Relatively high RQ values from degradation of readily degradable organics initially occurred. RQ then stabilized at slightly lower values, then decreased. Continuous emission of N2O was observed during the RQ decrease. Correlation between nitrification and N2O emission shows that the latter was triggered by nitrification. Mass balances demonstrated that the O2 consumption of nitrification (∼24.8mmol) was slightly higher than that of CO2 emission (∼20.0mmol), indicating that the RQ decrease was caused by the occurrence of nitrification. Results indicate that RQ is a useful index, which not only reflects the bioavailability of organics but also predicts the occurrence of nitrification and N2O emission in forced aerated composting. PMID:25987285

  8. Effect of extended aeration on the fate of particulate components in sludge stabilization.

    PubMed

    Özdemir, S; Çokgör, E U; İnsel, G; Orhon, D

    2014-12-01

    The study investigated the effect of extended aeration on the fate of particulate components of biological sludge in aerobic stabilization. Biological sludge was generated in a fill and draw reactor fed with domestic sewage and sustained at steady state, at a sludge age of 20 days. Particulate fractions of sludge were determined by model evaluation of the corresponding oxygen uptake rate profile. Extended aeration could not produce a mineralized biomass. External aerobic stabilization of the thickened sludge achieved a volatile suspended solids reduction of 68% after 60 days. High reduction could be attributed to the relatively higher rate for the hydrolysis of accumulated particulate metabolic products, compared to conventional activated sludge. Model evaluation based on death-regeneration mechanism indicated a gradually decreasing decay rate for solids; the first phase could be associated with the inactivation/death of the viable biomass and the second controlled by the slower breakdown of particulate metabolic products. PMID:25463786

  9. Binary Effect of Fly Ash and Palm Oil Fuel Ash on Heat of Hydration Aerated Concrete

    PubMed Central

    Mehmannavaz, Taha; Ismail, Mohammad; Radin Sumadi, Salihuddin; Rafique Bhutta, Muhammad Aamer; Samadi, Mostafa

    2014-01-01

    The binary effect of pulverized fuel ash (PFA) and palm oil fuel ash (POFA) on heat of hydration of aerated concrete was studied. Three aerated concrete mixes were prepared, namely, concrete containing 100% ordinary Portland cement (control sample or Type I), binary concrete made from 50% POFA (Type II), and ternary concrete containing 30% POFA and 20% PFA (Type III). It is found that the temperature increases due to heat of hydration through all the concrete specimens especially in the control sample. However, the total temperature rises caused by the heat of hydration through both of the new binary and ternary concrete were significantly lower than the control sample. The obtained results reveal that the replacement of Portland cement with binary and ternary materials is beneficial, particularly for mass concrete where thermal cracking due to extreme heat rise is of great concern. PMID:24696646

  10. Sludge reduction by direct addition of chlorine dioxide into a sequencing batch reactor under operational mode of repeatedly alternating aeration/non-aeration.

    PubMed

    Peng, Hong; Liu, Weiyi; Li, Yuanmei; Xiao, Hong

    2015-01-01

    The effect of direct addition of chlorine dioxide (ClO2) into a repeatedly alternating aeration/non-aeration sequencing batch reactor (SBR) on its sludge reduction and process performance was investigated. The experimental results showed that the sludge reduction efficiency was 32.9% and the observed growth yield (Yobs) of SBR was 0.11 kg VSS (volatile suspended solids) /kg COD (chemical oxygen demand) for 80 days' operation at the optimum ClO2 dosage of 2.0 mg/g TSS (total suspended solids). It was speculated that cell lysis and cryptic growth, uncoupled metabolism and endogenous metabolism were jointly responsible for the sludge reduction in this study. COD, NH3-N, total nitrogen (TN) and total phosphorus (TP) in the effluent increased on average 29.47, 4.44, 1.97 and 0.05 mg/L, respectively. However, the effluent quality still satisfied the first-class B discharge standards for municipal wastewater treatment plants in China. In that case, the sludge maintained fine viability with the specific oxygen uptake rate (SOUR) being 14.47 mg O2/(g VSS·h) and demonstrated good settleability with the sludge volume index (SVI) being 116 mL/g. The extra cost of sludge reduction at the optimum ClO2 dosage was estimated to be 2.24 CNY (or 0.36 dollar)/kg dry sludge. PMID:26524444

  11. Field trial of a new aeration system for enhancing biodegradation in a biopile.

    PubMed

    Li, L; Cunningham, C J; Pas, Valerie; Philp, J C; Barry, D A; Anderson, P

    2004-01-01

    The influence of a new aeration system on the biopile performance was investigated. The purpose was to increase biodegradation efficiency by optimising airflow through the pile. During a 1-month field trial, the performance of a new system using two perforated vertical pipes with wind-driven turbines was compared with that of a standard pile configuration with two horizontal perforated pipes. Both piles were composed of a similar mix of diesel-contaminated soils, woodchips, compost and NPK fertiliser. Hydrocarbons were recovered using solvent extraction, and determined both gravimetrically and by gas chromatography. Total heterotrophs, pH and moisture content were also assessed. Air pressure measurements were made to compare the efficiency of suction in the pipes. Results at the end of the experiment showed that there was no significant difference between the two piles in the total amount of hydrocarbon biodegradation. The normalised degradation rate was, however, considerably higher in the new system than in the standard one, suggesting that the vertical venting method may have improved the efficiency of the biological reactions in the pile. The pressure measurements showed a significant improvement in the suction produced by the new aeration system. However, many factors other than the airflow (oxygen supply) may influence and limit the biodegradation rates, including moisture content, age of contaminants and the climatic conditions. Additional experiments and modelling need to be carried out to explore further the new aeration method and to develop criteria and guidelines for engineering design of optimal aeration schemes in order to achieve maximum biodegradation in biopiles. PMID:14761751

  12. A Trade Study of Two Membrane-Aerated Biological Water Processors

    NASA Technical Reports Server (NTRS)

    Allada, Ram; Lange, Kevin; Vega. Leticia; Roberts, Michael S.; Jackson, Andrew; Anderson, Molly; Pickering, Karen

    2011-01-01

    Biologically based systems are under evaluation as primary water processors for next generation life support systems due to their low power requirements and their inherent regenerative nature. This paper will summarize the results of two recent studies involving membrane aerated biological water processors and present results of a trade study comparing the two systems with regards to waste stream composition, nutrient loading and system design. Results of optimal configurations will be presented.

  13. Control of aeration, aerobic SRT and COD input for mainstream nitritation/denitritation.

    PubMed

    Regmi, Pusker; Miller, Mark W; Holgate, Becky; Bunce, Ryder; Park, Hongkeun; Chandran, Kartik; Wett, Bernhard; Murthy, Sudhir; Bott, Charles B

    2014-06-15

    This work describes the development of an intermittently aerated pilot-scale process (V = 0.34 m(3)) operated without oxidized nitrogen recycle and supplemental carbon addition optimized for nitrogen removal via nitritation/denitritation. The aeration pattern was controlled using a novel aeration strategy based on set-points for reactor ammonia, nitrite and nitrate concentrations with the aim of maintaining equal effluent ammonia and nitrate + nitrite (NOx) concentrations. Further, unique operational and process control strategies were developed to facilitate the out-selection of nitrite oxidizing bacteria (NOB) based on optimizing the chemical oxygen demand (COD) input, imposing transient anoxia, aggressive solids retention time (SRT) operation towards ammonia oxidizing bacteria (AOB) washout and high dissolved oxygen (DO) (>1.5 mg/L). Sustained nitrite accumulation (NO2-N/NOx-N = 0.36 ± 0.27) was observed while AOB activity was greater than NOB activity (AOB: 391 ± 124 mgN/L/d, NOB: 233 ± 151 mgN/L/d, p < 0.001) during the entire study. The reactor demonstrated total inorganic nitrogen (TIN) removal rate of 151 ± 74 mgN/L/d at an influent COD/ [Formula: see text] -N ratio of 10.4 ± 1.9 at 25 °C. The TIN removal efficiency was 57  ±  25% within the hydraulic retention time (HRT) of 3 h and within an SRT of 4-8 days. Therefore, this pilot-scale study demonstrates that application of the proposed online aeration control is able to out-select NOB in mainstream conditions providing relatively high nitrogen removal without supplemental carbon and alkalinity at a low HRT. PMID:24721663

  14. Nitrogen removal over nitrite by aeration control in aerobic granular sludge sequencing batch reactors.

    PubMed

    Lochmatter, Samuel; Maillard, Julien; Holliger, Christof

    2014-07-01

    This study investigated the potential of aeration control for the achievement of N-removal over nitrite with aerobic granular sludge in sequencing batch reactors. N-removal over nitrite requires less COD, which is particularly interesting if COD is the limiting parameter for nutrient removal. The nutrient removal performances for COD, N and P have been analyzed as well as the concentration of nitrite-oxidizing bacteria in the granular sludge. Aeration phase length control combined with intermittent aeration or alternate high-low DO, has proven to be an efficient way to reduce the nitrite-oxidizing bacteria population and hence achieve N-removal over nitrite. N-removal efficiencies of up to 95% were achieved for an influent wastewater with COD:N:P ratios of 20:2.5:1. The total N-removal rate was 0.18 kgN·m-3·d-1. With N-removal over nitrate the N-removal was only 74%. At 20 °C, the nitrite-oxidizing bacteria concentration decreased by over 95% in 60 days and it was possible to switch from N-removal over nitrite to N-removal over nitrate and back again. At 15 °C, the nitrite-oxidizing bacteria concentration decreased too but less, and nitrite oxidation could not be completely suppressed. However, the combination of aeration phase length control and high-low DO was also at 15 °C successful to maintain the nitrite pathway despite the fact that the maximum growth rate of nitrite-oxidizing bacteria at temperatures below 20 °C is in general higher than the one of ammonium-oxidizing bacteria. PMID:25006970

  15. Nitrogen Removal over Nitrite by Aeration Control in Aerobic Granular Sludge Sequencing Batch Reactors

    PubMed Central

    Lochmatter, Samuel; Maillard, Julien; Holliger, Christof

    2014-01-01

    This study investigated the potential of aeration control for the achievement of N-removal over nitrite with aerobic granular sludge in sequencing batch reactors. N-removal over nitrite requires less COD, which is particularly interesting if COD is the limiting parameter for nutrient removal. The nutrient removal performances for COD, N and P have been analyzed as well as the concentration of nitrite-oxidizing bacteria in the granular sludge. Aeration phase length control combined with intermittent aeration or alternate high-low DO, has proven to be an efficient way to reduce the nitrite-oxidizing bacteria population and hence achieve N-removal over nitrite. N-removal efficiencies of up to 95% were achieved for an influent wastewater with COD:N:P ratios of 20:2.5:1. The total N-removal rate was 0.18 kgN·m−3·d−1. With N-removal over nitrate the N-removal was only 74%. At 20 °C, the nitrite-oxidizing bacteria concentration decreased by over 95% in 60 days and it was possible to switch from N-removal over nitrite to N-removal over nitrate and back again. At 15 °C, the nitrite-oxidizing bacteria concentration decreased too but less, and nitrite oxidation could not be completely suppressed. However, the combination of aeration phase length control and high-low DO was also at 15 °C successful to maintain the nitrite pathway despite the fact that the maximum growth rate of nitrite-oxidizing bacteria at temperatures below 20 °C is in general higher than the one of ammonium-oxidizing bacteria. PMID:25006970

  16. Evaluating the costs of packed-tower aeration and GAC for controlling selected organics

    SciTech Connect

    Adams, J.Q.; Clark, R.M.

    1991-01-01

    The article focuses on a preliminary cost analysis that compares liquid-phase granular activated carbon (GAC) treatment with packed-tower aeration (PTA) treatment, with and without air emissions control. The sensitivity of cost to design and operating variables is also discussed. For most of the contaminants examined, PTA appears to be more cost-effective than liquid-phase GAC, even when vapor-phase GAC is required in the stripping system.

  17. Turbine Aeration Design Software for Mitigating Adverse Environmental Impacts Resulting From Conventional Hydropower Turbines

    SciTech Connect

    Gulliver, John S.

    2015-03-01

    Conventional hydropower turbine aeration test-bed for computational routines and software tools for improving environmental mitigation technologies for conventional hydropower systems. In achieving this goal, we have partnered with Alstom, a global leader in energy technology development and United States power generation, with additional funding from the Initiative for Renewable Energy and the Environment (IREE) and the College of Science and Engineering (CSE) at the UMN

  18. The effect of aeration and effluent recycling on domestic wastewater treatment in a pilot-plant system of duckweed ponds.

    PubMed

    Ben-shalom, Miriam; Shandalov, Semion; Brenner, Asher; Oron, Gideon

    2014-01-01

    Three pilot-scale duckweed pond (DP) wastewater treatment systems were designed and operated to examine the effect of aeration and effluent recycling on treatment efficiency. Each system consisted of two DPs in series fed by pre-settled domestic sewage. The first system (duckweed+ conventional treatment) was 'natural' and included only duckweed plants. The second system (duckweed aeration) included aeration in the second pond. The third system (duckweed+ aeration+ circulation) included aeration in the second pond and effluent recycling from the second to the first pond. All three systems demonstrated similarly efficient removal of organic matter and nutrients. Supplemental aeration had no effect on either dissolved oxygen levels or on pollutant removal efficiencies. Although recycling had almost no influence on nutrient removal efficiencies, it had a positive impact on chemical oxygen demand and total suspended solids removals due to equalization of load and pH, which suppressed algae growth. Recycling also improved the appearance and growth rate of the duckweed plants, especially during heavy wastewater loads. PMID:24473305

  19. Effects of the combination of aeration and biofilm technology on transformation of nitrogen in black-odor river.

    PubMed

    Pan, Mei; Zhao, Jun; Zhen, Shucong; Heng, Sheng; Wu, Jie

    2016-01-01

    Excess nitrogen in urban river networks leading to eutrophication has become one of the most urgent environmental problems. Combinations of different aeration and biofilm techniques was designed to remove nitrogen from rivers. In laboratory water tank simulation experiments, we assessed the removal efficiency of nitrogen in both the overlying water and sediments by using the combination of the aeration and biofilm techniques, and then analyzed the transformation of nitrogen during the experiments. Aeration (especially sediment aeration) combined with the biofilms techniques was proved efficient in removing nitrogen from polluted rivers. Results indicated that the combination of sediment aeration and biofilms, with the highest nitrogen removal rate from the overlying water and sediments, was the most effective combined process, which especially inhibited the potential release of nitrogen from sediments by reducing the enzyme activity. It was found that the content of dissolved oxygen in water could be restored on the basis of the application of aeration techniques ahead, and the biofilm technique would be effective in purifying water in black-odor rivers. PMID:27508370

  20. A field study on phytoremediation of dredged sediment contaminated by heavy metals and nutrients: the impacts of sediment aeration.

    PubMed

    Wu, Juan; Yang, Lihua; Zhong, Fei; Cheng, Shuiping

    2014-12-01

    Compared to traditional chemical or physical treatments, phytoremediation has proved to be a cost-effective and environmentally sound alternative for remediation of contaminated dredged sediment. A field study was conducted in a sediment disposal site predominantly colonized by Typha angustifolia under different sediment moisture conditions to estimate the phytoremediation effects of dredged sediment. The moisture content was 37.30 % and 48.27 % in aerated and waterlogged sediment, respectively. Total nitrogen (TN) content was higher in the waterlogged sediment than in the aerated sediment. The total Cd contents were lower in aerated sediment, which was mainly resulted from the lower exchangeable fraction of Cd. The bioaccumulation of P, Cu and Pb in T. angustifolia was promoted by waterlogging, and the belowground tissue concentrations and accumulation factors (AFs) of Cu were higher than that of other metals, which can be explained by that Cu is an essential micronutrient for plants. Consistent with many previous studies, T. angustifolia showed higher metal levels in roots than in above-ground tissues at both the sediment conditions. Due to the improved biomass produced in the aerated sediment, the removals of nutrients and the metals by plant harvest were higher from aerated sediment than from waterlogged sediment. It was indicated that maintaining the dredged sediment aerated can avoid release risk and plant uptake of metals, while the opposite management option can promote phytoextraction of these contaminants. PMID:25012206

  1. Treatment of sewage sludge in a thermophilic membrane reactor (TMR) with alternate aeration cycles.

    PubMed

    Collivignarelli, Maria Cristina; Castagnola, Federico; Sordi, Marco; Bertanza, Giorgio

    2015-10-01

    The management of sewage sludge is becoming a more and more important issue, both at national and international level, in particular due to the uncertain recovery/disposal future options. Therefore, it is clear that the development of new technologies that can mitigate the problem at the source by reducing sludge production is necessary, such as the European Directive 2008/98/EC prescribes. This work shows the results obtained with a thermophilic membrane reactor, for processing a biological sludge derived from a wastewater treatment plant (WWTP) that treats urban and industrial wastewater. Sewage sludge was treated in a thermophilic membrane reactor (TMR), at pilot-scale (1 m(3) volume), with alternate aeration cycles. The experimentation was divided into two phases: a "startup phase" during which, starting with a psychrophilic/mesophilic biomass, thermophilic conditions were progressively reached, while feeding a highly biodegradable substrate; the obtained thermophilic biomass was then used, in the "regime phase", to digest biological sludge which was fed to the plant. Good removal yields were observed: 64% and 57% for volatile solids (VS) and total COD (CODtot), respectively, with an average hydraulic retention time (HRT) equal to 20 d, an organic loading rate (OLR) of about 1.4-1.8 kg COD m(-3) d(-1) and aeration/non aeration cycles alternated every 4 h. PMID:26233586

  2. Mechanism and design of intermittent aeration activated sludge process for nitrogen removal.

    PubMed

    Hanhan, Oytun; Insel, Güçlü; Yagci, Nevin Ozgur; Artan, Nazik; Orhon, Derin

    2011-01-01

    The paper provided a comprehensive evaluation of the mechanism and design of intermittent aeration activated sludge process for nitrogen removal. Based on the specific character of the process the total cycle time, (T(C)), the aerated fraction, (AF), and the cycle time ratio, (CTR) were defined as major design parameters, aside from the sludge age of the system. Their impact on system performance was evaluated by means of process simulation. A rational design procedure was developed on the basis of basic stochiometry and mass balance related to the oxidation and removal of nitrogen under aerobic and anoxic conditions, which enabled selected of operation parameters of optimum performance. The simulation results indicated that the total nitrogen level could be reduced to a minimum level by appropriate manipulation of the aerated fraction and cycle time ratio. They also showed that the effluent total nitrogen could be lowered to around 4.0 mgN/L by adjusting the dissolved oxygen set-point to 0.5 mg/L, a level which promotes simultaneous nitrification and denitrification. PMID:21104491

  3. Multiple electron transfer systems in oxygen reducing biocathodes revealed by different conditions of aeration/agitation.

    PubMed

    Rimboud, Mickaël; Bergel, Alain; Erable, Benjamin

    2016-08-01

    Oxygen reducing biocathodes were formed at -0.2V/SCE (+0.04V/SHE) from compost leachate. Depending on whether aeration was implemented or not, two different redox systems responsible for the electrocatalysis of oxygen reduction were evidenced. System I was observed at low potential (-0.03V/SHE) on cyclic voltammetries (CVs). It appeared during the early formation of the biocathode (few hours) and resisted the hydrodynamic conditions induced by the aeration. System II was observed at higher potential on CV (+0.46V/SHE); it required a longer lag time (up to 10days) and quiescent conditions to produce an electrochemical signal. The hydrodynamic effects produced by the forced aeration led to its extinction. From their different behaviors and examples in the literature, system I was identified as being a membrane-bound cytochrome-related molecule, while system II was identified as a soluble redox mediator excreted by the biofilm. This study highlighted the importance of controlling the local hydrodynamics to design efficient oxygen reducing biocathodes able to operate at high potential. PMID:27035588

  4. Improving industrial full-scale production of baker's yeast by optimizing aeration control.

    PubMed

    Blanco, Carlos A; Rayo, Julia; Giralda, José M

    2008-01-01

    This work analyzes the control of optimum dissolved oxygen of an industrial fed-batch procedure in which baker's yeast (Saccharomyces cerevisiae) is grown under aerobic conditions. Sugar oxidative metabolism was controlled by monitoring aeration, molasses flows, and yeast concentration in the propagator along the later stage of the propagation, and keeping pH and temperature under controlled conditions. A large number of fed-batch growth experiments were performed in the tank for a period of 16 h, for each of the 3 manufactured commercial products. For optimization and control of cultivations, the growth and metabolite formation were quantified through measurement of specific growth and ethanol concentration. Data were adjusted to a model of multiple lineal regression, and correlations representing dissolved oxygen as a function of aeration, molasses, yeast concentration in the broth, temperature, and pH were obtained. The actual influence of each variable was consistent with the mathematical model, further justified by significant levels of each variable, and optimum aeration profile during the yeast propagation. PMID:18567307

  5. Removal of nitrogen from MBT residues by leachate recirculation in combination with intermittent aeration.

    PubMed

    Tran, Hoai Nam; Münnich, Kai; Fricke, Klaus; Harborth, Peter

    2014-01-01

    Mechanical-biological treatment (MBT) techniques have been used to reduce the emission potential of waste before placement in landfills for a couple of years, especially in Europe. The main focus of MBT is on the reduction of native organic substances and not on nitrogen compounds. As a result, the concentrations of organic substances in leachate from MBT landfills are considerably reduced in comparison to leachates from municipal solid waste landfills, while the ammonia nitrogen concentrations remain at a high level. From the stabilization of old landfills it is well known that recirculation of leachate and supplementary aeration can reduce emissions to an acceptable level in a comparatively short time. In a series of laboratory-scale tests the efficiency of this technique for MBT residues was investigated under different boundary conditions. While the effect of leachate recirculation is also well known for MBT residues, the additional aeration has so far not been investigated. The results show that this technique has only a limited influence on the reduction of organic carbon compounds. In view of nitrogen compounds, only the additional aeration during recirculation shows a strong effect on the quality of leachate, in which the concentrations of ammonium and total nitrogen are reduced by more than 90%. The results indicate that by using simple techniques the long-term emission behavior of MBT residues can be quickly reduced to an acceptable level. PMID:24293068

  6. Nitrogen removal performance of intermittently aerated membrane bioreactor treating black water.

    PubMed

    Hocaoglu, S Murat; Atasoy, E; Baban, A; Insel, G; Orhon, D

    2013-01-01

    The study investigated the effect of intermittent aeration on the nitrogen removal performance of a membrane bioreactor (MBR) treating black water. A pilot-scale MBR with an effective volume of 630 L operating as a sequencing batch reactor (SBR) with intermittent aeration was used in the experiments. Substrate feeding was limited to the initial non-aerated phase. The MBR unit was sustained at a steady state at a sludge age of 60 d with a biomass concentration of around 10,000 mg/L for 3 months. The treated black water could be characterized with an average COD of 950 mg/L and total nitrogen of 172 mg/L, corresponding to a low COD/N ratio of 5.5. The selected MBR scheme was quite effective, reducing COD down to 26 mg/L, providing effective nitrification and yielding a total oxidized nitrogen concentration under 10 mg N/L. The nitrogen removal performance was substantially better than the level predicted by process stoichiometry, due to multiple anoxic configuration inducing additional nitrogen removal. Dissolved oxygen profiles associated with the cyclic operation of the system suggested that the incremental nitrogen removal could be attributed to simultaneous nitrification-denitrification, a commonly observed mechanism in MBR systems sustained at high biomass concentrations. PMID:24527634

  7. Screening-level risk assessment of Coxiella burnetii (Q fever) transmission via aeration of drinking water.

    PubMed

    Sales-Ortells, Helena; Medema, Gertjan

    2012-04-01

    A screening-level risk assessment of Q fever transmission through drinking water produced from groundwater in the vicinity of infected goat barnyards that employed aeration of the water was performed. Quantitative data from scientific literature were collected and a Quantitative Microbial Risk Assessment approach was followed. An exposure model was developed to calculate the dose to which consumers of aerated groundwater are exposed through aerosols inhalation during showering. The exposure assessment and hazard characterization were integrated in a screening-level risk characterization using a dose-response model for inhalation to determine the risk of Q fever through tap water. A nominal range sensitivity analysis was performed. The estimated risk of disease was lower than 10(-4) per person per year (pppy), hence the risk of transmission of C. burnetii through inhalation of drinking water aerosols is very low. The sensitivity analysis shows that the most uncertain parameters are the aeration process, the transport of C. burnetii in bioaerosols via the air, the aerosolization of C. burnetii in the shower, and the air filtration efficiency. The risk was compared to direct airborne exposure of persons in the vicinity of infected goat farms; the relative risk of exposure through inhalation of drinking water aerosols was 0.002%. PMID:22309101

  8. Impact of carbon to nitrogen ratio and aeration regime on mainstream deammonification.

    PubMed

    Han, M; De Clippeleir, H; Al-Omari, A; Wett, B; Vlaeminck, S E; Bott, C; Murthy, S

    2016-01-01

    While deammonification of high-strength wastewater in the sludge line of sewage treatment plants has become well established, the potential cost savings spur the development of this technology for mainstream applications. This study aimed at identifying the effect of aeration and organic carbon on the deammonification process. Two 10 L sequencing bath reactors with different aeration frequencies were operated at 25°C. Real wastewater effluents from chemically enhanced primary treatment and high-rate activated sludge process were fed into the reactors with biodegradable chemical oxygen demand/nitrogen (bCOD/N) of 2.0 and 0.6, respectively. It was found that shorter aerobic solids retention time (SRT) and higher aeration frequency gave more advantages for aerobic ammonium-oxidizing bacteria (AerAOB) than nitrite oxidizing bacteria (NOB) in the system. From the kinetics study, it is shown that the affinity for oxygen is higher for NOB than for AerAOB, and higher dissolved oxygen set-point could decrease the affinity of both AerAOB and NOB communities. After 514 days of operation, it was concluded that lower organic carbon levels enhanced the activity of anoxic ammonium-oxidizing bacteria (AnAOB) over denitrifiers. As a result, the contribution of AnAOB to nitrogen removal increased from 40 to 70%. Overall, a reasonably good total removal efficiency of 66% was reached under a low bCOD/N ratio of 2.0 after adaptation. PMID:27438242

  9. Computational Fluid Dynamics Simulation of Flows in an Oxidation Ditch Driven by a New Surface Aerator

    PubMed Central

    Huang, Weidong; Li, Kun; Wang, Gan; Wang, Yingzhe

    2013-01-01

    Abstract In this article, we present a newly designed inverse umbrella surface aerator, and tested its performance in driving flow of an oxidation ditch. Results show that it has a better performance in driving the oxidation ditch than the original one with higher average velocity and more uniform flow field. We also present a computational fluid dynamics model for predicting the flow field in an oxidation ditch driven by a surface aerator. The improved momentum source term approach to simulate the flow field of the oxidation ditch driven by an inverse umbrella surface aerator was developed and validated through experiments. Four kinds of turbulent models were investigated with the approach, including the standard k−ɛ model, RNG k−ɛ model, realizable k−ɛ model, and Reynolds stress model, and the predicted data were compared with those calculated with the multiple rotating reference frame approach (MRF) and sliding mesh approach (SM). Results of the momentum source term approach are in good agreement with the experimental data, and its prediction accuracy is better than MRF, close to SM. It is also found that the momentum source term approach has lower computational expenses, is simpler to preprocess, and is easier to use. PMID:24302850

  10. Use of floating balls for reducing bacterial aerosol emissions from aeration in wastewater treatment processes.

    PubMed

    Hung, Hsueh Fen; Kuo, Yu Mei; Chien, Chih Ching; Chen, Chih Chieh

    2010-03-15

    The microorganism emissions from aeration in the wastewater treatment process may adversely affect air quality and human health. To control the liquid-to-air transport of microorganisms, commercially available balls were used and their control efficiencies were evaluated by a lab-scale aeration system. Escherichia coli as the test agent were aerosolized by the aeration system and size-fractionated E. coli-containing aerosol samples were collected by using an Andersen six-stage impactor with eosin methylene blue agar for subsequent culturing and enumeration of colonies. Aerosol samples were obtained without any control measure and with balls of four diameters (1.9, 2.9, 3.4 and 4.8 cm) in one, three and five layers covering the bubbling liquid surface. Experimental results showed that the control efficiencies of balls on bacterial aerosols varied from over 50% to nearly 100% under various control settings and substantially increased as the ball size decreased and the number of applied layers increased. PMID:19939557

  11. Application of Oxygen-Enriched Aeration in the Production of Bacitracin by Bacillus licheniformis

    PubMed Central

    Flickinger, M. C.; Perlman, D.

    1979-01-01

    The physiological effects of controlling the dissolved oxygen tension at 0.01, 0.02, and 0.05 atm by the use of oxygen-enriched aeration were investigated during growth and bacitracin production by Bacillus licheniformis ATCC 10716. Up to a 2.35-fold increase in the final antibiotic yield and a 4-fold increase in the rate of bacitracin synthesis were observed in response to O2-enriched aeration. The increase in antibiotic production was accompanied by increased respiratory activity and an increase in the specific productivity of the culture from 1.3 to 3.6 g of antibiotic per g of cell mass produced. Oxygen enrichment of the aeration decreased medium carbohydrate uptake and the maximum specific growth rate of B. licheniformis from 0.6 h−1 to as low as 0.15 h−1, depending upon the level of enrichment and the conditions of oxygen transfer rate (impeller speed). The response of this culture to O2 enrichment suggests that this method of controlling the dissolved oxygen tension for antibiotic-producing cultures may simulate conditions that would occur if the carbon source were fed slowly, as is often employed to optimize antibiotic production. Analysis of the biologically active bacitracins produced by B. licheniformis ATCC 10716 suggested that the ratio of biologically active peptides was not changed by O2 enrichment, nor were any new biologically active compounds formed. Images PMID:34361

  12. Effect of forced aeration on citric acid production by Aspergillus sp. mutants in SSF.

    PubMed

    Rodrigues, Cristine; Vandenberghe, Luciana P S; Sturm, Wilerson; Dergint, Dario E A; Spier, Michele Rigon; de Carvalho, Júlio Cesar; Soccol, Carlos R

    2013-12-01

    Citric acid (CA) is one of the most important products of fermentation in the world. A great variety of agro-industrial residues can be used in solid state fermentation. Aspergillus niger parental strain (CCT 7716) and two strains obtained by mutagenesis (CCT 7717 and CCT 7718) were evaluated in Erlenmeyer flasks and glass columns using citric pulp (CP) as substrate/support, sugarcane molasses and methanol. Best results using glass columns (forced aeration) were found in the fourth day of fermentation: 278.4, 294.9 and 261.1 g CA/kg of dry CP with CCT 7716, CCT 7718 and CCT 7717, respectively. In Erlenmeyer flasks (aeration by diffusion) CA reached 410.7, 446.8 and 492.7 g CA/kg of dry CP with CCT 7716, CCT 7718 and CCT 7717, respectively. The aeration by diffusion improved CA production by the three strains. A data acquisition system specially developed for biotechnological processes analysis was used to perform the respirometric parameters measurement. PMID:23760557

  13. Relationship between respiratory quotient, nitrification, and nitrous oxide emissions in a forced aerated composting process

    SciTech Connect

    Tsutsui, Hirofumi; Fujiwara, Taku; Inoue, Daisuke; Ito, Ryusei; Matsukawa, Kazutsugu; Funamizu, Naoyuki

    2015-08-15

    Highlights: • RQ can be an indicator of N{sub 2}O emission in forced aerated composting process. • Emission of N{sub 2}O with nitrification was observed with RQ decrease. • Mass balances demonstrated the RQ decrease was caused by nitrification. • Conversion ratio of oxidized ammonia and total N to N{sub 2}O were ∼2.7%. - Abstract: We assessed the relationship between respiratory quotient (RQ) and nitrification and nitrous oxide (N{sub 2}O) emission in forced aerated composting using lab-scale reactors. Relatively high RQ values from degradation of readily degradable organics initially occurred. RQ then stabilized at slightly lower values, then decreased. Continuous emission of N{sub 2}O was observed during the RQ decrease. Correlation between nitrification and N{sub 2}O emission shows that the latter was triggered by nitrification. Mass balances demonstrated that the O{sub 2} consumption of nitrification (∼24.8 mmol) was slightly higher than that of CO{sub 2} emission (∼20.0 mmol), indicating that the RQ decrease was caused by the occurrence of nitrification. Results indicate that RQ is a useful index, which not only reflects the bioavailability of organics but also predicts the occurrence of nitrification and N{sub 2}O emission in forced aerated composting.

  14. Volatile organic compound emission rate from diffused aeration systems. 1: Mass transfer modeling

    SciTech Connect

    Chern, J.M.; Yu, C.F.

    1995-08-01

    The activated sludge process is one of the most commonly used biochemical oxidation process for the secondary treatment of municipal and industrial wastewaters. The release of volatile organic compounds (VOCs) from wastewater treatment plants has recently caused great concern. In wastewater treatment plants, many operation units such s equalization and aeration involve oxygen transfer between wastewater and air. While oxygen is transferred from air to wastewater, VOCs are stripped from wastewater to air. Due to increasingly stringent environmental regulations, wastewater treatment operators have to do VOC inventory of their facilities. A mass transfer model for VOCs is therefore called for to assess VOC emission rates from wastewater treatment processes. Almost all existing methods adopt an oxygen mass transfer model standardized by the American Society of Civil Engineers (ASCE) to evaluate VOC emission rates. A new and more fundamental oxygen mass transfer model for diffused aeration systems was developed to assess the VOC emission rates. The new model provides better insight of the VOC mass transfer process and requires only aeration performance data to predict the VOC emission rates. The results and implications of both models were discussed and compared.

  15. Ex-situ forced aeration of soil piles: A physical model

    SciTech Connect

    Battaglia, A.; Morgan, D.J. )

    1994-08-01

    This paper presents a physical model of a technology in its early stages of development, which is here referred to as [open quotes]ex-situ forced aeration of soil piles,[close quotes] or, briefly, [open quotes]soil pile aeration.[close quotes] The model can be used in a dual capacity. First, it can be used to screen the technology; that is, to determine if, based on soil characteristics and contamination levels, the technology is at all applicable. Second, if the technology is deemed applicable, the model can be used as a design tool to optimize the basic design parameters, which are the pile radius and length, and the vacuum blower characteristics. The physical model presented in this paper provides a useful framework for understanding the influence that the design and soil parameters have on the effectiveness and/or viability of the technology, and can be a useful tool for preliminary design of aeration piles. 9 refs., 9 figs., 3 tabs.

  16. Experimental and theoretical analysis of tubular membrane aeration for Mammalian cell bioreactors.

    PubMed

    Qi, Hanshi N; Goudar, Chetan T; Michaels, James D; Henzler, Hans-Jugen; Jovanovic, Goran N; Konstantinov, Konstantin B

    2003-01-01

    A combination of experimental and theoretical approaches was used to characterize the dynamics of oxygen transfer in a membrane-aerated bioreactor. Pressure profiles along the length of the membrane at varying entrance and exit pressures were determined by actual experimental measurements, unlike most previous studies that have relied solely on theoretical descriptions of the pressure profile in the tubing. The mass transfer coefficient, k(L)a, was also determined under these conditions and was found to be essentially independent of tubing exit pressure. Measurement of the tubing pressure profile coupled with estimation of k(L)a allowed for computation of the oxygen transfer rate (OTR) along the length of the tubing. A mathematical model that incorporated friction pressure loss and losses due to tubing bending was developed to describe the pressure and hence OTR characteristics of membrane-aerated systems. The applicability of the model was verified by testing it on experimentally measured pressure data, and in all cases the model accurately described experimental data. When tubing properties are known, the mathematical model presented in this study allows for a priori estimation of OTR profiles along the length of the tubing. This information is vital for optimal design and scale-up of membrane-aerated bioreactors for mammalian cell culture. PMID:12892480

  17. Biogas production enhancement using semi-aerobic pre-aeration in a hybrid bioreactor landfill.

    PubMed

    Cossu, Raffaello; Morello, Luca; Raga, Roberto; Cerminara, Giulia

    2016-09-01

    Landfilling continues to be one of the main methods used in managing Municipal Solid Waste (MSW) worldwide, particularly in developing countries. Although in many countries national legislation aims to reduce this practice as much as possible, landfill is a necessary and unavoidable step in closing the material cycle. The need for innovative waste management techniques to improve landfill management and minimize the adverse environmental impact produced has resulted in an increasing interest in innovative systems capable of accelerating waste stabilization. Landfill bioreactors allow decomposition kinetics to be increased and post-operational phase to be shortened; in particular, hybrid bioreactors combine the benefits afforded by both aerobic and anaerobic processes. Six bioreactor simulators were used in the present study: four managed as hybrid, with an initial semi-aerobic phase and a second anaerobic phase, and two as anaerobic control bioreactors. The main goal of the first aerated phase is to reduce Volatile Fatty Acids (VFA) in order to increase pH and enhance methane production during the anaerobic phase; for this reason, air injection was stopped only when these parameters reached the optimum range for methanogenic bacteria. Biogas and leachate were constantly monitored throughout the entire methanogenic phase with the aim of calibrating a Gompertz Model and evaluating the effects of pre-aeration on subsequent methane production. The results showed that moderate and intermittent pre-aeration produces a positive effect both on methane potential and in the kinetics of reaction. PMID:26531047

  18. A new design for high stability pressure-controlled ventilation for small animal lung imaging

    NASA Astrophysics Data System (ADS)

    Kitchen, M. J.; Habib, A.; Fouras, A.; Dubsky, S.; Lewis, R. A.; Wallace, M. J.; Hooper, S. B.

    2010-02-01

    We have developed a custom-designed ventilator to deliver a stable pressure to the lungs of small animals for use in imaging experiments. Our ventilator was designed with independent pressure vessels to separately control the Peak Inspiratory Pressure (PIP) and Positive End Expiratory Pressure (PEEP) to minimise pressure fluctuations during the ventilation process. The ventilator was computer controlled through a LabVIEW interface, enabling experimental manipulations to be performed remotely whilst simultaneously imaging the lungs in situ. Mechanical ventilation was successfully performed on newborn rabbit pups to assess the most effective ventilation strategies for aerating the lungs at birth. Highly stable pressures enabled reliable respiratory gated acquisition of projection radiographs and a stable prolonged (15 minute) breath-hold for high-resolution computed tomography of deceased rabbit pups at different lung volumes.

  19. The Spatiotemporal Cellular Dynamics of Lung Immunity

    PubMed Central

    Lelkes, E.; Headley, M.B.; Thornton, E.E.; Looney, M.R.; Krummel, M.F.

    2014-01-01

    The lung is a complex structure that is interdigitated with immune cells. Understanding the 4-dimensional process of normal and defective lung function and immunity has been a centuries-old problem. Challenges intrinsic to the lung have limited adequate microscopic evaluation of its cellular dynamics in real time, until recently. Because of emerging technologies, we now recognize alveolar-to-airway transport of inhaled antigen. We understand the nature of neutrophil entry during lung injury and are learning more about cellular interactions during inflammatory states. Insights are also accumulating in lung development and the metatastatic niche of the lung. Here we assess the developing technology of lung imaging, its merits for studies of pathophysiology and areas where further advances are needed. PMID:24974157

  20. Lung Transplantation

    MedlinePlus

    ... years. Their conditions are so severe that other treatments, such as medicines or breathing devices, no longer work. Lung transplants most often are used to treat people who have severe COPD Cystic fibrosis Idiopathic pulmonary fibrosis Alpha-1 antitrypsin deficiency Pulmonary ...

  1. Physicochemical properties and ability to generate free radicals of ambient coarse, fine, and ultrafine particles in the atmosphere of Xuanwei, China, an area of high lung cancer incidence

    NASA Astrophysics Data System (ADS)

    Lu, Senlin; Yi, Fei; Hao, Xiaojie; Yu, Shang; Ren, Jingjing; Wu, Minghong; Jialiang, Feng; Yonemochi, Shinich; Wang, Qingyue

    2014-11-01

    The link between the high incidence of lung cancer and harmful pollutants emitted by local coal combustion in Xuanwei, Yunnan province, China, has been a focus of study since the 1980s. However, the mechanisms responsible for the high lung cancer rate remain unclear, necessitating further study. Since a close relationship between ambient air particle pollution and respiratory diseases exists, we sampled size-resolved ambient particles from the atmosphere of Xuanwei. In our indoor experiment, cutting-edge methods, including scanning electron microscopy coupled with energy dispersive X-ray detection (SEM/EDX), particle-induced X-ray emission (PIXE), electronic paramagnetic resonance (EPR) and the cell-free DCFH-DA assay, were employed to investigate the physicochemical properties, the potential to generate free radicals and the oxidative potential of ambient coarse (diameter, 1.8-10 μm), fine (diameter, 0.1-1.8 μm), and ultrafine (diameter, <0.1 μm) particles. We found the total mass concentrations of the size-resolved particles collected in spring were higher than that in early winter. Mass percentage of fine particles accounted for 68% and 61% of the total particulate mass in spring and in early winter samples, respectively, indicating that fine particles were the major component of the Xuanwei ambient particulate matters. On the other hand, the results of SEM/EDX analysis showed that the coarse particles were dominated by minerals, the fine particles by soot aggregates and fly ashes, and the ultrafine particles by soot particles and unidentified particles. Our PIXE results revealed that crustal elements (Ca, Ti Si, Fe) were mainly distributed in coarse particles, while trace metals (Cr, Mn, Ni, Cu, Zn, Pb) dominated in the fine particle fraction, and S, a typical element emitted by coal combustion, mainly resided in fine particles collected from the winter atmosphere. EPR results indicated that the magnitude of free radical intensity caused by size

  2. Effects of etiologically defined respiratory infections on lung function and its growth in an area of low air pollution - spirometry in young children when illness-free

    SciTech Connect

    Collier, A.M.; Strope, G.L.; Helms, R.W.; LaVange, L.M.; Clyde, W.A. Jr.

    1981-03-01

    This longitudinal study was performed in a group of 3-12 year old children to document normal lung growth patterns as measured by spirometry. By clinical and laboratory parameters, these children were free of illness at the time of study and had been for the preceding 21 days. Spirometry was performed prospectively over a period of six years in 69 children (27 black females, 23 black males, 10 white females, and 9 white males) all from a day care center. Eight hundred fifteen spirometric tests were made on these children. Six spirometric parameters were measured: forced vital capacity (FVC), forced expiratory volume in one second (FEV1), peak expiratory flow (PEF), forced expiratory flow during the middle half of the FVC (FEF25-75%), and maximum expiratory flows after 50% and 75% of the FVC have been exhaled (Vmax50% and Vmax75%, respectively). There were significant differences between the regression lines (considering slope and intercept) for all six parameters when black females were compared to black males, white females to white males, black females to white females and black males to white males, except for Vmax75% for the comparison of black females to black males and white females to white males. These slopes and intercepts were similar to those reported by others for children of similar age and height. This study demonstrates that spirometry can be performed reliabley at an early age in a day care center population, that there are significant racial and sexual differences in spirometric volume and flow parameters and that the variability of these measurements is proportional to height rather than being a constant.

  3. Changes in the chemical and physicochemical properties of the solid fraction of cattle slurry during composting using different aeration strategies.

    PubMed

    Cáceres, Rafaela; Flotats, Xavier; Marfà, Oriol

    2006-01-01

    Replacement of peat as a growing medium by a renewable material, such as an organic waste, is an issue of concern since harvesting of peat has a considerable environmental impact and, actually, it is a non-renewable resource. Cattle manure is a readily available organic waste, which means that once it goes through the composting process, it can be used as an alternative to peat, specifically, the solid fraction obtained from mechanical liquid-solid separation of cattle slurry (SF). Studies have shown it to be suitable for such uses. The purpose of this study was to detect possible changes in the physicochemical and chemical properties of SF when it is composted using different aeration strategies, with an emphasis on the changes that would make it feasible for use as a substrate. With this aim in mind, an experiment was designed with three aeration strategies that would be used during composting. The first consisted of applying air through a static method (forced ventilation). The second involved improving aeration by adding a bulking agent and a dynamic turning method. In the third strategy, aeration was carried out by turning (control). The results show that the different aeration strategies had a clear effect on the evolution of pH, electrical conductivity (EC), nitrate-N, ammonia-N and bicarbonate content. Nitrification was favored under good aeration conditions using the static composting method, probably due to the greater availability of ammonia-N that was transformed into nitrate-N. In general, the low buffering capacity allowed for a reduction of the pH during the curing stage of composting (in conjunction with low temperatures during this period), a characteristic that favors the use of this compost as a growing medium. We also conclude that measuring bicarbonate levels during composting could be used as an indicator of the possible acidification of the material and as a way of evaluating the level of material aeration. PMID:16146687

  4. Coupling of bio-PRB and enclosed in-well aeration system for remediation of nitrobenzene and aniline in groundwater.

    PubMed

    Liu, Na; Ding, Feng; Wang, Liu; Liu, Peng; Yu, Xiaolong; Ye, Kang

    2016-05-01

    A laboratory-scale bio-permeable reactive barrier (bio-PRB) was constructed and combined with enclosed in-well aeration system to treat nitrobenzene (NB) and aniline (AN) in groundwater. Batch-style experiments were first conducted to evaluate the effectiveness of NB and AN degradation, using suspension (free cells) of degrading consortium and immobilized consortium by a mixture of perlite and peat. The NB and AN were completely degraded in <3 days using immobilized consortium, while 3-5 days were required using free cells. The O2 supply efficiency of an enclosed in-well aeration system was assessed in a box filled with perlite and peat. Dissolved O2 (DO) concentrations increased to 8-12 mg L(-1) in 12 h for sampling ports within 12 cm of the aeration well. A diffusion coefficient as 33.5 cm(2) s(-1) was obtained. The DO concentration was >4 mg L(-1) when the aeration system was applied into the bio-PRB system. The NB and AN were effectively removed when the aeration system was functional in the bio-PRB. The removal efficiency decreased when the aeration system malfunctioned for 20 days, thus indicating that DO was an important factor for the degradation of NB and AN. The regain of NB and AN removal after the malfunction indicates the robustness of degradation consortium. No original organics and new formed by-products were observed in the effluent. The results indicate that NB and AN in groundwater can be completely mineralized in a bio-PRB equipped with enclosed in-well aeration system and filled with perlite and peat attached with degrading consortium. PMID:26865481

  5. Fe hydroxyphosphate precipitation and Fe(II) oxidation kinetics upon aeration of Fe(II) and phosphate-containing synthetic and natural solutions

    NASA Astrophysics Data System (ADS)

    van der Grift, B.; Behrends, T.; Osté, L. A.; Schot, P. P.; Wassen, M. J.; Griffioen, J.

    2016-08-01

    Exfiltration of anoxic Fe-rich groundwater into surface water and the concomitant oxidative precipitation of Fe are important processes controlling the transport of phosphate (PO4) from agricultural areas to aquatic systems. Here, we explored the relationship between solution composition, reaction kinetics, and the characteristics of the produced Fe hydroxyphosphate precipitates in a series of aeration experiments with anoxic synthetic water and natural groundwater. A pH stat device was used to maintain constant pH and to record the H+ production during Fe(II) oxidation in the aeration experiments in which the initial aqueous P/Fe ratios ((P/Fe)ini), oxygen concentration and pH were varied. In general, Fe(II) oxidation proceeded slower in the presence of PO4 but the decrease of the PO4 concentration during Fe(II) oxidation due to the formation of Fe hydroxyphosphates caused additional deceleration of the reaction rate. The progress of the reaction could be described using a pseudo-second-order rate law with first-order dependencies on PO4 and Fe(II) concentrations. After PO4 depletion, the Fe(II) oxidation rates increased again and the kinetics followed a pseudo-first-order rate law. The first-order rate constants after PO4 depletion, however, were lower compared to the Fe(II) oxidation in a PO4-free solution. Hence, the initially formed Fe hydroxyphosphates also affect the kinetics of continuing Fe(II) oxidation after PO4 depletion. Presence of aqueous PO4 during oxidation of Fe(II) led to the formation of Fe hydroxyphosphates. The P/Fe ratios of the precipitates ((P/Fe)ppt) and the recorded ratio of H+ production over decrease in dissolved Fe(II) did not change detectably throughout the reaction despite a changing P/Fe ratio in the solution. When (P/Fe)ini was 0.9, precipitates with a (P/Fe)ppt ratio of about 0.6 were formed. In experiments with (P/Fe)ini ratios below 0.6, the (P/Fe)ppt decreased with decreasing (P/Fe)ini and pH value. Aeration experiments with

  6. Estimation of lung tissue incompressibility variation throughout respiration for tumor targeting in lung radiotherapy

    NASA Astrophysics Data System (ADS)

    Shirzadi, Zahra; Samani, Abbas

    2013-03-01

    A novel technique is proposed to characterize lung tissue incompressibility variation during respiration. Lung tissue incompressibility variation stems from significant air content variation in the tissue throughout respiration. Estimating lung tissue incompressibility and its variation is critical for computer assisted tumor motion tracking. Continuous tumor motion during respiration is a major challenge in lung cancer treatment by external beam radiotherapy. If not accounted for, this motion leads to areas of radiation over dosage for the lung normal tissues. Since no effective imaging modality is available for real-time lung tumor tracking, computer based modeling which has the capability for accurate tissue deformation estimation can be a good alternative. Lung tissue deformation estimation can be made using the lung Finite Element (FE) model where its accuracy depends on input tissue biomechanical properties including incompressibility parameter. In this research, an optimization algorithm is proposed to estimate the incompressibility parameter function in terms of respiration cycle time. In this algorithm, the incompressibility parameter and lung pressure values are varied systematically until optimal values, which result in maximum similarity between acquired and simulated 4D CT images of the lung, are achieved for each respiration time point. The simulated images are constructed using a reference image in conjunction with the deformation field obtained from the lung's FE model in each respiration time increment. We demonstrated that utilizing the calculated function along with respiratory system FE modeling leads to accurate tumor targeting, hence potentially improving lung radiotherapy outcome.

  7. The effect of aeration and recirculation on a sand-based hybrid constructed wetland treating low-strength domestic wastewater.

    PubMed

    Zapater-Pereyra, M; Kyomukama, E; Namakula, V; van Bruggen, J J A; Lens, P N L

    2016-08-01

    The Duplex-constructed wetland (CW) is a hybrid system composed of a vertical flow (VF) CW on top of a horizontal flow filter (HFF). Each compartment is designed to play a different role: aerobic treatment in the VF CW due to intermittent feeding and anoxic treatment in the HFF due to saturated conditions. Three Duplex-CWs were used in this study: Control, Aerated and Recirculating. The role of each compartment was tested for pollutant removal and micro-invertebrate abundance. In all systems, the VF CW removed mainly organic matter, solids and NH4(+)-N. Pathogens were removed in both compartments. Likewise, total nitrogen removal occurred in both compartments, only the Recirculating HFF was not able to denitrify the nitrogen due to the slightly more oxic conditions as compared to the other systems. All systems met discharge guidelines for organic matter, but only the Control and Aerated systems met those for total nitrogen. At the applied loading rates, the pollutant removal was not significantly enhanced by the use of aeration and recirculation. Therefore, operation as in the Control system, without aeration or recirculation, is recommended for the tested Duplex-CWs. If artificial aeration will be used in CWs, the support material should be carefully selected to allow a proper air distribution. PMID:26732367

  8. Aeration effects on the partitioning of a PCB to anoxic estuarine sediment pore water dissolved organic matter

    SciTech Connect

    Pedersen, J.A.; Gabelich, C.J.; Lin, C.H.; Suffet, I.H.

    1999-05-01

    Pore water dissolved organic matter (DOM) plays an important role in the distribution, mobility, and bioavailability of hydrophobic organic chemicals (HOCs) in sediment environments. The effect of aeration on the partitioning of 2,2{prime},4,4{prime}-tetrachlorobiphenyl (TeCB) to anoxic pore water DOM from three estuarine sites was investigated. Pore water DOM was fractionated into molecular size and polarity fractions by ultrafiltration and XAD-8 resin chromatography. Total organic carbon analysis was utilized to determine shifts in molecular size and polarity distributions. Changes in functional groups and aromaticity were evaluated for whole and fractionated pore waters by specific UV absorbance at 254 nm (SUVA{sub 254}). The solubility enhancement method was used to determine the partitioning of TeCB to whole and fractionated pore water DOM. At two sites, the overall TeCB-DOM distribution coefficient decreased by an order of magnitude after aeration. The higher molecular size and all polarity fractions exhibited a decrease in partitioning behavior upon aeration. The aromaticity and TeCB-DOM distribution coefficient of the lowest molecular size fraction decreased upon aeration. The highest and lowest molecular size fractions contributed the most to overall partitioning. The observed aeration effects in anoxic estuarine sediment pore waters differed significantly from those previously reported in freshwater systems.

  9. Immunotoxic potential of aeration lagoon effluents for the treatment of domestic and hospital wastewaters in the freshwater mussel Elliptio complanata.

    PubMed

    Gagné, Francois; André, Chantale; Fortier, Marlène; Fournier, Michel

    2012-01-01

    Municipal wastewaters are major sources of pollution for the aquatic biota. The purpose of this study was to determine the levels of some pharmaceutical products and the immunotoxic potential of a municipal wastewater aeration lagoon for the treatment of the domestic wastewaters of a small town with wastewater inputs from a 400-bed hospital complex. Endemic mussels were collected, caged and placed in the final aeration lagoon and at sites 1 km upstream and 1 km downstream of the effluent outfall in the receiving river for a period of 14 days. The results showed that the final aeration lagoon contained high levels of total coliforms, conductivity and low dissolved oxygen (2.9 mg/L) as well as detectable amounts of trimethoprim, carbamazepine, gemfibrozil, and norfloxacin at concentrations exceeding 50 ng/L. The lagoon effluent was indeed toxic to the mussel specimens, as evidenced by the appearance of mortality after 14 days (10% mortality), decreased mussel weight-to-shell-length ratio and loss of hemocyte viability. The number of adhering hemocytes, phagocytic activity, total nitrite levels and arachidonic cyclooxygenase activity were significantly higher in mussels placed in the final aeration lagoon. A multivariate analysis also revealed that water pH, conductivity, total coliforms and dissolved oxygen were the endpoints most closely linked with phagocytic activity, the amount of adhering hemocytes and loss of hemocyte viability. In conclusion, exposure of mussels to treated aerated lagoon wastewater is deleterious to freshwater mussels where the immune system is compromised. PMID:22893952

  10. Impact of aeration strategy on CHO cell performance during antibody production.

    PubMed

    Velez-Suberbie, M Lourdes; Tarrant, Richard D R; Tait, Andrew S; Spencer, Daniel I R; Bracewell, Daniel G

    2013-01-01

    Stirred tank bioreactors using suspension adapted mammalian cells are typically used for the production of complex therapeutic proteins. The hydrodynamic conditions experienced by cells within this environment have been shown to directly impact growth, productivity, and product quality and therefore an improved understanding of the cellular response is critical. Here we investigate the sub-lethal effects of different aeration strategies on Chinese hamster ovary cells during monoclonal antibody production. Two gas delivery systems were employed to study the presence and absence of the air-liquid interface: bubbled direct gas sparging and a non-bubbled diffusive silicone membrane system. Additionally, the effect of higher gas flow rate in the sparged bioreactor was examined. Both aeration systems were run using chemically defined media with and without the shear protectant Pluronic F-68 (PF-68). Cells were unable to grow with direct gas sparging without PF-68; however, when a silicone membrane aeration system was implemented growth was comparable to the sparged bioreactor with PF-68, indicating the necessity of shear protectants in the presence of bubbles. The cultures exposed to increased hydrodynamic stress were shown by flow cytometry to have decreased F-actin intensity within the cytoskeleton and enter apoptosis earlier. This indicates that these conditions elicit a sub-lethal physiological change in cells that would not be detected by the at-line assays which are normally implemented during cell culture. These physiological changes only result in a difference in continuous centrifugation performance under high flow rate conditions. Product quality was more strongly affected by culture age than the hydrodynamic conditions tested. PMID:23074084

  11. Oxidants in Acute and Chronic Lung Disease

    PubMed Central

    Mannam, Praveen; Srivastava, Anup; Sugunaraj, Jaya Prakash; Lee, Patty J; Sauler, Maor

    2015-01-01

    Oxidants play an important role in homeostatic function, but excessive oxidant generation has an adverse effect on health. The manipulation of Reactive Oxygen Species (ROS) can have a beneficial effect on various lung pathologies. However indiscriminate uses of anti-oxidant strategies have not demonstrated any consistent benefit and may be harmful. Here we propose that nuanced strategies are needed to modulate the oxidant system to obtain a beneficial result in the lung diseases such as Acute Lung Injury (ALI) and Chronic Obstructive Pulmonary Disease (COPD). We identify novel areas of lung oxidant responses that may yield fruitful therapies in the future. PMID:25705575

  12. Fate of microconstituents in biosolids composted in an aerated silage bag.

    PubMed

    Lozano, Nuria; Andrade, Natasha A; Deng, Di; Torrents, Alba; Rice, Clifford P; McConnell, Laura L; Ramirez, Mark; Millner, Patricia D

    2014-01-01

    Although most composting studies report pathogen concentrations, little is known about the fate of Endocrine Disruptor Chemicals (EDCs) during composting. In this study, a positively aerated polyethylene bag composting system was filled with a mixture of woodchips and limed biosolids from a large Waste Water Treatment Plant (WWTP) to study the removal efficiency of two different groups of EDCs. Two antibacterial compounds, Triclocarban (TCC) and Triclosan (TCS), and a TCS byproduct, Methyltriclosan (MeTCS), as well as seven congeners of flame retardants known as PBDEs (Polybrominated Diphenyl Ethers) were studied during two phases of composting: 1) a thermophilic phase, in which positive mechanical aeration, pushing air into and through the materials matrix, was conducted for 2 months; and 2) a curing and stabilization phase in which no mechanical aeration was provided and the bag was opened to ambient passive aeration to simulate storage conditions for seven months. Our results showed that while TCC concentrations remained constant, TCS degradation took place during both phases. The degradation of TCS was corroborated by the formation of MeTCS in both phases. The TCS concentrations decreased from 18409 ± 1,877 to 11955 ± 288 ng g(-1) dry wt. during the thermophilic phase and declined from 11,955 ± 288 to 7,244 ± 909. ng g(-1) dry wt. by the end of the curing phase. Thus, slightly greater TCS transformation occurred during the second than during the first (35.1 vs. 39.4%). MeTCS concentrations increased from 189.3 ± 8.6 to 364.6 ± 72.5 ng g(-1) dry wt. during the first phase and reached 589.0 ± 94.9 ng g(-1) dry wt. at the end of the second phase. PBDEs concentrations were below quantification limits for all but two of the congeners analyzed (BDE-47 and BDE-99). PBDE concentrations were measured at the end of the first phase only and were comparable to initial concentrations. PMID:24521417

  13. Comparisons of IL-8, ROS and p53 responses in human lung epithelial cells exposed to two extracts of PM2.5 collected from an e-waste recycling area, China

    NASA Astrophysics Data System (ADS)

    Yang, Fangxing; Jin, Shiwei; Xu, Ying; Lu, Yuanan

    2011-04-01

    To identify the different effects of organic-soluble and water-soluble pollutants adsorbed on PM2.5 (PM: particulate matter) released from e-waste (electrical/electronic waste) on inflammatory response, oxidative stress and DNA damage, interleukin-8 (IL-8), reactive oxygen species (ROS) and p53 protein levels were determined and compared in human lung epithelial A549 cells exposed to extracts of PM2.5 collected from two sampling sites in an e-waste recycling area in China. It is found that both extracts induced increases of IL-8 release, ROS production and p53 protein expression. The differences between the organic-soluble and water-soluble extracts were determined as of significance for ROS production (p < 0.05) and p53 protein expression (p < 0.01). The ROS production and p53 protein expression induced by the organic-soluble extracts were found to be greater than those induced by the water-soluble extracts, for both sampling sites. The results indicated that PM2.5 collected from the e-waste recycling areas could lead to inflammatory response, oxidative stress and DNA damage, and the organic-soluble extracts had higher potential to induce such adverse effects on human health.

  14. Lung diffusion testing

    MedlinePlus

    ... as: Emphysema Interstitial fibrosis Pulmonary embolism Pulmonary hypertension Sarcoidosis Lung hemorrhage Asthma Risks There are no significant ... Read More Asbestosis Interstitial lung disease Lung disease Sarcoidosis Update Date 11/19/2015 Updated by: Denis ...

  15. How Lungs Work

    MedlinePlus

    ... Health and Diseases > How Lungs Work How Lungs Work The Respiratory System Your lungs are part of ... Parts of the Respiratory System and How They Work Airways SINUSES are hollow spaces in the bones ...

  16. Lung Carcinoid Tumor: Surgery

    MedlinePlus

    ... for lung carcinoid tumor symptoms Surgery to treat lung carcinoid tumors Surgery is the main treatment for ... often be cured by surgery alone. Types of lung surgery Different operations can be used to treat ( ...

  17. Childhood Interstitial Lung Disease

    MedlinePlus

    ... from the NHLBI on Twitter. What Is Childhood Interstitial Lung Disease? Childhood interstitial (in-ter-STISH-al) lung disease, ... with similar symptoms—it's not a precise diagnosis. Interstitial lung disease (ILD) also occurs in adults. However, the cause ...

  18. Lung diffusion testing

    MedlinePlus

    Lung diffusion testing measures how well the lungs exchange gases. This is an important part of lung testing , because ... Gender Height Hemoglobin (the protein in red blood cells that carries oxygen) level

  19. The effects of micro-aeration on the phylogenetic diversity of microorganisms in a thermophilic anaerobic municipal solid-waste digester.

    PubMed

    Tang, Yueqin; Shigematsu, Toru; Ikbal; Morimura, Shigeru; Kida, Kenji

    2004-05-01

    We demonstrated previously that micro-aeration allows construction of an effective thermophilic methane-fermentation system for treatment of municipal solid waste (MSW) without production of H(2)S. In the present study, we compared the microbial communities in a thermophilic MSW digester without aeration and with micro-aeration by fluorescence in situ hybridization (FISH), denaturing gradient gel electrophoresis (DGGE), phylogenetic analysis of libraries of 16S rRNA gene clones and quantitative real-time PCR. Moreover, we studied the activity of sulfate-reducing bacteria (SRB) by analysis of the transcription of the gene for dissimilatory sulfite reductase (dsr). Experiments using FISH revealed that microorganisms belonging to the domain Bacteria dominated in the digester both without aeration and with micro-aeration. Phylogenetic analysis based on 16S rRNA gene and analysis of bacteria by DGGE did not reveal any obvious difference within the microbial communities under the two aeration conditions, and bacteria affiliated with the phylum Firmicutes were dominant. In Archaea, the population of Methanosarcina decreased while the population of Methanoculleus increased as a result of micro-aerations as revealed by the analysis of 16S rRNA gene clones and quantitative real-time PCR. Reverse transcription and PCR (RT-PCR) demonstrated the transcription of dsrA not only in the absence of aeration but also in the presence of micro-aeration, even under conditions where no H(2)S was detected in the biogas. In conclusion, micro-aeration has no obvious effects on the phylogenetic diversity of microorganisms. Furthermore, the activity of SRBs in the digester was not repressed even though the concentration of H(2)S in the biogas was very low under the micro-aeration conditions. PMID:15159157

  20. Sex Steroid Signaling: Implications for Lung Diseases

    PubMed Central

    Sathish, Venkatachalem; Martin, Yvette N.; Prakash, Y.S.

    2015-01-01

    There is increasing recognition that the sex hormones (estrogen, progesterone, and testosterone) have biological and pathophysiological actions in peripheral, non-reproductive organs, including the lung. Clinically, sex differences in the incidence, morbidity and mortality of lung diseases such as asthma, chronic obstructive pulmonary disease (COPD), pulmonary fibrosis, lung cancer and pulmonary hypertension have been noted, although intrinsic sex differences vs. the roles of sex steroids are still not well-understood. Accordingly, it becomes important to ask the following questions: 1) Which sex steroids are involved? 2) How do they affect different components of the lung under normal circumstances? 3) How does sex steroid signaling change in or contribute to lung disease, and in this regard, are sex steroids detrimental or beneficial? As our understanding of sex steroid signaling in the lung improves, it is important to consider whether such information can be used to develop new therapeutic strategies to target lung diseases, perhaps in both sexes or in a sex-specific manner. In this review, we focus on the basics of sex steroid signaling, and the current state of knowledge regarding how they influence structure and function of specific lung components across the life span and in the context of some important lung diseases. We then summarize the potential for sex steroids as useful biomarkers and therapeutic targets in these lung diseases as a basis for future translational research in the area of gender and individualized medicine. PMID:25595323

  1. Temperature dependence of stream aeration coefficients and the effect of water turbulence: a critical review.

    PubMed

    Demars, B O L; Manson, J R

    2013-01-01

    The gas transfer velocity (K(L)) and related gas transfer coefficient (k(2) = K(L)A/V, with A, area and V, volume) at the air-water interface are critical parameters in all gas flux studies such as green house gas emission, whole stream metabolism or industrial processes. So far, there is no theoretical model able to provide accurate estimation of gas transfer in streams. Hence, reaeration is often estimated with empirical equations. The gas transfer velocity need then to be corrected with a temperature coefficient θ = 1.0241. Yet several studies have long reported variation in θ with temperature and 'turbulence' of water (i.e. θ is not a constant). Here we re-investigate thoroughly a key theoretical model (Dobbins model) in detail after discovering important discrepancies. We then compare it with other theoretical models derived from a wide range of hydraulic behaviours (rigid to free continuous surface water, wave and waterfalls with bubbles). The results of the Dobbins model were found to hold, at least theoretically in the light of recent advances in hydraulics, although the more comprehensive results in this study highlighted a higher degree of complexity in θ's behaviour. According to the Dobbins model, the temperature coefficient θ, could vary from 1.005 to 1.042 within a temperature range of 0-35 °C and wide range of gas transfer velocities, i.e. 'turbulence' condition (0.005 < K(L) < 1.28 cm min(-1)). No other theoretical models showed any significant variability in θ with change in 'turbulence', and only modest variability in θ with change in temperature. However, the other theoretical models did not have the same temperature coefficient θ (with 1.000 < θ < 1.056 within 0-35 °C). A model integrating turbulence and bubble mediated gas transfer velocities suggested a lower temperature dependence for bubble (1.013<θ < 1.017) than turbulence (1.023<θ < 1.031) mediated processes. As it stands, the effect of turbulence on the temperature dependence

  2. Lung surgery - discharge

    MedlinePlus

    Thoracotomy - discharge; Lung tissue removal - discharge; Pneumonectomy - discharge; Lobectomy - discharge; Lung biopsy - discharge; Thoracoscopy - discharge; Video-assisted thoracoscopic surgery - discharge; VATS - discharge; Thoracoscopy - discharge

  3. Interstitial lung disease

    MedlinePlus

    Diffuse parenchymal lung disease; Alveolitis; Idiopathic pulmonary pneumonitis (IPP) ... The lungs contain tiny air sacs (alveoli), which is where oxygen is absorbed. These air sacs expand with each ...

  4. Lung surgery - discharge

    MedlinePlus

    Thoracotomy - discharge; Lung tissue removal - discharge; Pneumonectomy - discharge; Lobectomy - discharge; Lung biopsy - discharge; Thoracoscopy - discharge; Video-assisted thoracoscopic surgery - discharge; VATS - ...

  5. Advanced start-up of anaerobic attached film expanded bed reactor by pre-aeration of biofilm carrier.

    PubMed

    Ye, Fen-xia; Chen, Ying-xu; Feng, Xiao-shan

    2005-01-01

    The start-up and performance of the anaerobic attached film expanded bed (AAFEB) reactor with pre-aeration of carrier were investigated. The carriers of the reactors had been aerated for 10 days before they were put into the AAFEB reactors. The results indicated that the reactors advance the start-up by 15 days, and maintain higher efficiency when they were subjected to organic and hydraulic loading shock, but during steady-state operation, the reactors did not show better performance than the control reactors without pre-aeration of carrier. The thicker biofilm and higher biomass concentration of the reactors with pre-aeration were observed during the start-up period, but the difference between two types of reactors tapered with the time course, and at the steady-state operation, the difference between two types of reactors on these two parameters was not obvious. Maximum specific methane or acids production rates, dehydrogenase activity and coenzyme F(420) content were continuously higher than those of the control reactors. After running 30 days, filamentous bacteria dominated in the reactors with pre-aeration, whereas the cocci were predominant species in the control reactors. It was suggested that the action of the biofilm is strongly dependent on the biofilm thickness or the biomass concentration in normal circumstances, but under adverse circumstances, such as organic or hydraulic loading shock, the characteristics and activity of the anaerobic granular sludge play key roles on the reactor performance. These results clearly indicated that pre-aeration of carrier favor to enhance the start-up and performance of AAFEB reactor. PMID:15364089

  6. Linking biofilm growth to fouling and aeration performance of fine-pore diffuser in activated sludge.

    PubMed

    Garrido-Baserba, Manel; Asvapathanagul, Pitiporn; McCarthy, Graham W; Gocke, Thomas E; Olson, Betty H; Park, Hee-Deung; Al-Omari, Ahmed; Murthy, Sudhir; Bott, Charles B; Wett, Bernhard; Smeraldi, Joshua D; Shaw, Andrew R; Rosso, Diego

    2016-03-01

    Aeration is commonly identified as the largest contributor to process energy needs in the treatment of wastewater and therefore garners significant focus in reducing energy use. Fine-pore diffusers are the most common aeration system in municipal wastewater treatment. These diffusers are subject to fouling and scaling, resulting in loss in transfer efficiency as biofilms form and change material properties producing larger bubbles, hindering mass transfer and contributing to increased plant energy costs. This research establishes a direct correlation and apparent mechanistic link between biofilm DNA concentration and reduced aeration efficiency caused by biofilm fouling. Although the connection between biofilm growth and fouling has been implicit in discussions of diffuser fouling for many years, this research provides measured quantitative connection between the extent of biofouling and reduced diffuser efficiency. This was clearly established by studying systematically the deterioration of aeration diffusers efficiency during a 1.5 year period, concurrently with the microbiological study of the biofilm fouling in order to understand the major factors contributing to diffuser fouling. The six different diffuser technologies analyzed in this paper included four different materials which were ethylene-propylene-diene monomer (EPDM), polyurethane, silicone and ceramic. While all diffusers foul eventually, some novel materials exhibited fouling resistance. The material type played a major role in determining the biofilm characteristics (i.e., growth rate, composition, and microbial density) which directly affected the rate and intensity at what the diffusers were fouled, whereas diffuser geometry exerted little influence. Overall, a high correlation between the increase in biofilm DNA and the decrease in αF was evident (CV < 14.0 ± 2.0%). By linking bacterial growth with aeration efficiency, the research was able to show quantitatively the causal connection

  7. Lung Circulation.

    PubMed

    Suresh, Karthik; Shimoda, Larissa A

    2016-01-01

    The circulation of the lung is unique both in volume and function. For example, it is the only organ with two circulations: the pulmonary circulation, the main function of which is gas exchange, and the bronchial circulation, a systemic vascular supply that provides oxygenated blood to the walls of the conducting airways, pulmonary arteries and veins. The pulmonary circulation accommodates the entire cardiac output, maintaining high blood flow at low intravascular arterial pressure. As compared with the systemic circulation, pulmonary arteries have thinner walls with much less vascular smooth muscle and a relative lack of basal tone. Factors controlling pulmonary blood flow include vascular structure, gravity, mechanical effects of breathing, and the influence of neural and humoral factors. Pulmonary vascular tone is also altered by hypoxia, which causes pulmonary vasoconstriction. If the hypoxic stimulus persists for a prolonged period, contraction is accompanied by remodeling of the vasculature, resulting in pulmonary hypertension. In addition, genetic and environmental factors can also confer susceptibility to development of pulmonary hypertension. Under normal conditions, the endothelium forms a tight barrier, actively regulating interstitial fluid homeostasis. Infection and inflammation compromise normal barrier homeostasis, resulting in increased permeability and edema formation. This article focuses on reviewing the basics of the lung circulation (pulmonary and bronchial), normal development and transition at birth and vasoregulation. Mechanisms contributing to pathological conditions in the pulmonary circulation, in particular when barrier function is disrupted and during development of pulmonary hypertension, will also be discussed. © 2016 American Physiological Society. Compr Physiol 6:897-943, 2016. PMID:27065170

  8. Who Needs a Lung Transplant?

    MedlinePlus

    ... from the NHLBI on Twitter. Who Needs a Lung Transplant? Your doctor may recommend a lung transplant ... lungs to pick up oxygen. Applying to a Lung Transplant Program Lung transplants are done in medical ...

  9. The impact of aeration on the competition between polyphosphate accumulating organisms and glycogen accumulating organisms.

    PubMed

    Carvalheira, Mónica; Oehmen, Adrian; Carvalho, Gilda; Eusébio, Mário; Reis, Maria A M

    2014-12-01

    In wastewater treatment plants (WWTPs), aeration is the major energetic cost, thus its minimisation will improve the cost-effectiveness of the process. This study shows that both the dissolved oxygen (DO) concentration and aerobic hydraulic retention time (HRT) affect the competition between polyphosphate accumulating organisms (PAOs) and glycogen accumulating organisms (GAOs). At low DO levels, Accumulibacter PAOs were shown to have an advantage over Competibacter GAOs, as PAOs had a higher oxygen affinity and thus largely maintained their aerobic activity at low DO levels, while GAO activity decreased. Bioreactor operation at low DO levels was found to increase the PAO fraction of the sludge. Furthermore, an increase in aerobic HRT (at a DO level of 2 mg O2/L), promoted the proliferation of GAOs over PAOs, decreasing the EBPR efficiency. Overall, this study shows that low aeration can be beneficial for EBPR performance through selecting for PAOs over GAOs, which should be incorporated into WWTP models in order to minimise energetic costs and improve WWTP sustainability. PMID:25222333

  10. GHG emissions during the high-rate production of compost using standard and advanced aeration strategies.

    PubMed

    Puyuelo, B; Gea, T; Sánchez, A

    2014-08-01

    In this study, we have evaluated different strategies for the optimization of the aeration during the active thermophilic stage of the composting process of source-selected Organic Fraction of Municipal Solid Waste (or biowaste) using reactors at bench scale (50L). These strategies include: typical cyclic aeration, oxygen feedback controller and a new self-developed controller based on the on-line maximization of the oxygen uptake rate (OUR) during the process. Results highlight differences found in the emission of most representative greenhouse gases (GHG) emitted from composting (methane and nitrous oxide) as well as in gases typically related to composting odor problems (ammonia as typical example). Specifically, the cyclic controller presents emissions that can double that of OUR controller, whereas oxygen feedback controller shows a better performance with respect to the cyclic controller. A new parameter, the respiration index efficiency, is presented to quantitatively evaluate the GHG emissions and, in consequence, the main negative environmental impact of the composting process. Other aspects such as the stability of the compost produced and the consumption of resources are also evaluated for each controller. PMID:24873708

  11. Aerobic and two-stage anaerobic-aerobic sludge digestion with pure oxygen and air aeration.

    PubMed

    Zupancic, Gregor D; Ros, Milenko

    2008-01-01

    The degradability of excess activated sludge from a wastewater treatment plant was studied. The objective was establishing the degree of degradation using either air or pure oxygen at different temperatures. Sludge treated with pure oxygen was degraded at temperatures from 22 degrees C to 50 degrees C while samples treated with air were degraded between 32 degrees C and 65 degrees C. Using air, sludge is efficiently degraded at 37 degrees C and at 50-55 degrees C. With oxygen, sludge was most effectively degraded at 38 degrees C or at 25-30 degrees C. Two-stage anaerobic-aerobic processes were studied. The first anaerobic stage was always operated for 5 days HRT, and the second stage involved aeration with pure oxygen and an HRT between 5 and 10 days. Under these conditions, there is 53.5% VSS removal and 55.4% COD degradation at 15 days HRT - 5 days anaerobic, 10 days aerobic. Sludge digested with pure oxygen at 25 degrees C in a batch reactor converted 48% of sludge total Kjeldahl nitrogen to nitrate. Addition of an aerobic stage with pure oxygen aeration to the anaerobic digestion enhances ammonium nitrogen removal. In a two-stage anaerobic-aerobic sludge digestion process within 8 days HRT of the aerobic stage, the removal of ammonium nitrogen was 85%. PMID:17251012

  12. Large eddy simulation of dilute bubbly turbulent flows for aerating hydrofoils

    NASA Astrophysics Data System (ADS)

    Hajit, Mohammad; Sotiropoulos, Fotis

    2014-11-01

    We have proposed a formulation for the large eddy simulation of dilute bubbly flows by converting the governing equations to a more loosely-coupled form. This formulation provides an efficient numerical procedure for two-way coupling of bubbly flows at low gas holdups. Subgrid-scale turbulence modeling is based on the dynamic procedure of Germano for the liquid phase and the Jakobson approach for the gas phase. Wall-modeling is implemented using the method of Cabot & Moin. Our approach is employed to simulate flow over aerating hydrofoils at different angles of attack. A structured body-fitted C-grid is employed for domain discretization. Validation of our computational code, for C-grids, is carried out by simulating single-phase flows over a NACA0012 airfoil (20° AOA) with laminar flow and an E387 airfoil (6° AOA) with turbulent flow. Comparisons with available computational and experimental data in terms of time averaged drag coefficient, lift coefficient, separation bubble length, and reattachment point proves the validity of our computational code. The aerating hydrofoil simulation utilizes a NACA0015 hydrofoil, for which experiments were carried out at Saint Anthony Falls Laboratory. Comparisons between computational and experimental datasets show promising results. This work is supported by the U.S. Dept. of Energy and the Hydro Reasearch Foundation.

  13. Effects of toxicity, aeration, and reductant supply on trichloroethylene transformation by a mixed methanotrophic culture.

    PubMed Central

    Alvarez-Cohen, L; McCarty, P L

    1991-01-01

    The trichloroethylene (TCE) transformation rate and capacity of a mixed methanotrophic culture at room temperature were measured to determine the effects of time without methane (resting), use of an alternative energy source (formate), aeration, and toxicity of TCE and its transformation products. The initial specific TCE transformation rate of resting cells was 0.6 mg of TCE per mg of cells per day, and they had a finite TCE transformation capacity of 0.036 mg of TCE per mg of cells. Formate addition resulted in increased initial specific TCE transformation rates (2.1 mg/mg of cells per day) and elevated transformation capacity (0.073 mg of TCE per mg of cells). Significant declines in methane conversion rates following exposure to TCE were observed for both resting and formate-fed cells, suggesting toxic effects caused by TCE or its transformation products. TCE transformation and methane consumption rates of resting cells decreased with time much more rapidly when cells were shaken and aerated than when they remained dormant, suggesting that the transformation ability of methanotrophs is best preserved by storage under anoxic conditions. PMID:2036009

  14. Disequilibrium of hydrogen sulfide in ground water by aeration. Final report

    SciTech Connect

    Ritchey, J.D.

    1981-04-24

    This study examines removal of hydrogen sulfide gas by aeration as a result of bubbling air through water in the well before it is pumped out of the ground. The field study demonstrated that a substantial amount of hydrogen sulfide gas could be successfully removed by the method tested. Evaluation of water analyses indicated three processes that caused reduction in the concentration of hydrogen sulfide gas: (1) hydrogen sulfide gas was released from water to air by gas transfer--indicated by a strong 'rotten egg odor,' characteristic of hydrogen sulfide gas that was emitted from the wellhead; (2) hydrogen sulfide gas was oxidized to elemental sulfur--evidenced by an increase in dissolved oxygen measured in water samples and by clouding of pumped water; and (3) hydrogen sulfide gas was partially ionized--indicated by an increase in the pH and the redox potential of water samples. This field study demonstrates that in-well aeration is an effective method of hydrogen sulfide gas removal in domestic wells with potential application in larger installations.

  15. On the occurrence of anoxic microniches, denitrification, and sulfate reduction in aerated activated sludge

    SciTech Connect

    Schramm, A.; Santegoeds, C.M.; Nielsen, H.K.; Ploug, H.; Wagner, M.; Pribyl, M.; Wanner, J.; Amann, R.; De Beer, D.

    1999-09-01

    A combination of different methods was applied to investigate the occurrence of anaerobic processes in aerated activated sludge. Microsensor measurements (O{sub 2}, NO{sub 2}{sup {minus}}, NO{sub 3}{sup {minus}}, and H{sub 2}S) were performed on single sludge flocs to detect anoxic niches, nitrate reduction, or sulfate reduction on a microscale. Incubations of activated sludge with {sup 15}NO{sub 3}{sup {minus}} and {sup 35}SO{sub 4}{sup 2{minus}} were used to determine denitrification and sulfate reduction rates on a batch scale. In four of six investigated sludges, no anoxic zones developed during aeration, and consequently denitrification rates were very low. However, in two sludges anoxia in flocs coincided with significant denitrification rates. Sulfate reduction could not be detected in any sludge in either the microsensor or the batch investigation, not even under short-term anoxic conditions. In contrast, the presence of sulfate-reducing bacteria was shown by fluorescence in situ hybridization with 16S rRNA-targeted oligonucleotide probes and by PCR-based detection of genes coding for the dissimilatory sulfite reductase. A possible explanation for the absence of advection, i.e., facilitated by flow through pores and channels. This possibility is suggested by the irregularity of some oxygen profiles and by confocal laser scanning microscopy of the three-dimensional floc structures, which showed that flocs from the two sludges in which anoxic zones were found were apparently denser than flocs from the other sludges.

  16. Aerated biofilter with seasonally varied operation modes for the production of irrigation water.

    PubMed

    Meda, A; Cornel, P

    2010-01-01

    Water reuse for agricultural irrigation can contribute to the conservation of valuable water resources and opens the possibility to reuse the wastewater's nutrients (N and P) at the same time. As irrigation is usually limited to vegetation periods, effluent requirements for treated wastewater may vary seasonally. A process concept for wastewater treatment with variable operation modes for the seasonal production of nutrient-rich irrigation water and nutrient-poor discharge water is proposed. It is shown that a two-step process consisting of organics removal followed by biological aerated filters (biofilters) for nitrogen removal is a promising combination which allows a flexible and seasonally varied operation with a fast re-start of biological nitrification after shut-down periods. To date, there is no commonly accepted practice amongst operators to take biofilters out of service for periods of time while - at the same time - maintaining biological activity to enable a quick start-up. This paper shows that during shut-down periods the activity drop rate is the smallest if the filter bed is maintained flooded and without aeration; then a very quick re-start is possible. PMID:20220239

  17. Direct sewage up-concentration by submerged aerated and vibrated membranes.

    PubMed

    Mezohegyi, G; Bilad, M R; Vankelecom, Ivo F J

    2012-08-01

    Membrane filtration is a promising technology for realising the so-called ZeroWasteWater concept, i.e. the wastewater can be up-concentrated and the retentate can sequentially be sent to a bioreactor (e.g., for energy production) while the permeate is aimed for reuse. In the present study, aerated and novel vibrated membrane filtration systems were evaluated as possible techniques for both energy and water recovery through the up-concentration of sewage from a municipal wastewater treatment plant. The lab-scale experiments proved the clear advantage of vibrated membrane filtration over the aerated system, considering both the filtration performance (fouling control) and energy usage. Both microfiltration systems were found efficient in up-concentrating the COD, but not the nitrogen nor the phosphorus. The semi-continuous pilot-scale experiment could not confirm the usefulness of the process which was due to both fast in situ microbial COD degradation and fast particulate COD settling in the feed tank. PMID:22695138

  18. Effect of auxotrophies on yeast performance in aerated fed-batch reactor

    SciTech Connect

    Landi, Carmine; Paciello, Lucia; Alteriis, Elisabetta de; Brambilla, Luca; Parascandola, Palma

    2011-10-28

    Highlights: Black-Right-Pointing-Pointer The paper contributes to fill the gap existing between the basic and applied research. Black-Right-Pointing-Pointer Mathematical model sheds light on the physiology of auxotrophic yeast strains. Black-Right-Pointing-Pointer Yeast behavior in fed-batch is influenced by biological and environmental determinants. Black-Right-Pointing-Pointer Process optimization would make possible the production of heterologous proteins which are not yet on the market. -- Abstract: A systematic investigation on the effects of auxotrophies on the performance of yeast in aerated fed-batch reactor was carried out. Six isogenic strains from the CEN.PK family of Saccharomyces cerevisiae, one prototroph and five auxotrophs, were grown in aerated fed-batch reactor using the same operative conditions and a proper nutritional supplementation. The performance of the strains, in terms of final biomass decreased with increasing the number of auxotrophies. Auxotrophy for leucine exerted a profound negative effect on the performance of the strains. Accumulation of reactive oxygen species (ROS) in the cells of the strain carrying four auxotrophies and its significant viability loss, were indicative of an oxidative stress response induced by exposure of cells to the environmental conditions. The mathematical model was fundamental to highlight how the carbon flux, depending on the number and type of auxotrophies, was diverted towards the production of increasingly large quantities of energy for maintenance.

  19. A general correlation to predict axial dispersion coefficients in aerated channel reactors.

    PubMed

    Lemoullec, Yann; Potier, Olivier; Gentric, Caroline; Leclerc, Jean-Pierre

    2008-03-01

    Tracer studies have been widely applied to characterize the flow behavior in activated sludge reactors. The channel reactor with bottom aerators is one of the widespread designs in large wastewater treatment plants. Its flow behavior is well modeled either as a plug flow reactor with axial dispersion or as the perfect mixing cells in series. Several correlations have been developed to estimate the dispersion coefficients as a function of operating and geometrical parameters. These correlations fit properly the data derived from a given reactor in the range of operating and geometrical parameters for which they have been determined. Unfortunately they cannot be applied straightforwardly with a sufficient level of confidence to scale-up industrial units or scale-down laboratory pilots. Recently, two papers have proposed more general correlations [Makinia, J., Wells, S.A., 2005. Evaluation of empirical formulae for estimation of the longitudinal dispersion in activated sludge reactors. Water Res. 39, 1533-1542; Potier, O., Leclerc, J.-P., Pons, M.-N., 2005. Influence of geometrical and operating parameters on the axial dispersion in an aerated channel reactor. Water Res. 39, 4454-4462] but they are still not able to represent the whole set of data from the literature. This paper proposes a general correlation, which can represent all the available and usable sets of data from the literature and more than 170 experimental results obtained in our laboratory with a precision of 18%. PMID:18063006

  20. Functioning of microbial complexes in aerated layers of a highmoor peat bog

    NASA Astrophysics Data System (ADS)

    Golovchenko, A. V.; Bogdanova, O. Yu.; Stepanov, A. L.; Polyanskaya, L. M.; Zvyagintsev, D. G.

    2010-09-01

    Monitoring was carried out using the luminescent-microscopic method of the abundance parameters of different groups of microorganisms in a monolith and in the mixed layers of a highmoor peat bog (oligotrophic residual-eutrophic peat soil) in a year-long model experiment. The increase of the aeration as a result of mixing of the layers enhanced the activity of the soil fungi. This was attested to by the following changes: the increase of the fungal mycelium length by 6 times and of the fungal biomass by 4 times and the double decrease of the fraction of spores in the fungal complex. The response of the fungal complex to mixing was different in the different layers of the peat bog. The maximal effect was observed in the T1 layer and the minimal one in the T2 layer. The emission of CO2 in the mixed samples was 1.5-2 times higher than that from the undisturbed peat samples. In contrast with the fungi, the bacteria and actinomycetes were not affected by the aeration of the highmoor layers.

  1. Beyond volutrauma in ARDS: the critical role of lung tissue deformation

    PubMed Central

    2011-01-01

    Ventilator-induced lung injury (VILI) consists of tissue damage and a biological response resulting from the application of inappropriate mechanical forces to the lung parenchyma. The current paradigm attributes VILI to overstretching due to very high-volume ventilation (volutrauma) and cyclic changes in aeration due to very low-volume ventilation (atelectrauma); however, this model cannot explain some research findings. In the present review, we discuss the relevance of cyclic deformation of lung tissue as the main determinant of VILI. Parenchymal stability resulting from the interplay of respiratory parameters such as tidal volume, positive end-expiratory pressure or respiratory rate can explain the results of different clinical trials and experimental studies that do not fit with the classic volutrauma/atelectrauma model. Focusing on tissue deformation could lead to new bedside monitoring and ventilatory strategies. PMID:21489320

  2. Lung cancer.

    PubMed

    Frödin, J E

    1996-01-01

    This synthesis of the literature on radiotherapy for lung cancer is based on 80 scientific articles, including 2 meta-analyses, 29 randomized studies, 19 prospective studies, and 21 retrospective studies. These studies involve 28172 patients. Basic treatment for limited-stage small cell lung cancer (SCLC), is chemotherapy. Addition of radiotherapy to the primary tumor and mediastinum reduces local recurrence, prolongs long-term survival, and is often indicated. Current, and future, studies can be expected to show successive improvements in results for SCLC by optimizing the combination of radiotherapy and chemotherapy. Should these treatments be given simultaneously or sequentially, and in which order? Which fractionation is best? Probably, no change in resource requirements for radiotherapy will be necessary, with the possible exception of changes in fractionation. Surgery constitutes primary treatment for nonsmall cell lung cancer (NSCLC) stages I and II. Radiotherapy may provide an alternative for patients who are inoperable for medical reasons. The value of radiotherapy following radical surgery for NSCLC remains to be shown. It is not indicated based on current knowledge. For NSCLC stage III, radiotherapy shrinks tumors and prolongs survival at 2 and 3 years. Whether it influences long-term survival after 5 years has not been shown. Considering the side effects of treatment, one must question whether limited improvements in survival motivate routine radiotherapy in these patients. Earlier attempts to add chemotherapy to radiotherapy to improve treatment results of NSCLC have not yielded convincing results. Several studies are currently on-going. Prophylactic cranial irradiation (PCI) greatly reduces the risk for brain metastases from SCLC. However, it has little influence on survival. Many treatment centers give PCI to SCLC patients who have achieved complete remission. This practice may be questioned since PCI is associated with serious complications. PCI is

  3. Lung surfactant.

    PubMed Central

    Rooney, S A

    1984-01-01

    Aspects of pulmonary surfactant are reviewed from a biochemical perspective. The major emphasis is on the lipid components of surfactant. Topics reviewed include surfactant composition, cellular and subcellular sites as well as pathways of biosynthesis of phosphatidylcholine, disaturated phosphatidylcholine and phosphatidylglycerol. The surfactant system in the developing fetus and neonate is considered in terms of phospholipid content and composition, rates of precursor incorporation, activities of individual enzymes of phospholipid synthesis and glycogen content and metabolism. The influence of the following hormones and other factors on lung maturation and surfactant production is discussed: glucocorticoids, thyroid hormone, estrogen, prolactin, cyclic AMP, beta-adrenergic and cholinergic agonists, prostaglandins and growth factors. The influence of maternal diabetes, fetal sex, stress and labor are also considered. Nonphysiologic and toxic agents which influence surfactant in the fetus, newborn and adult are reviewed. PMID:6145585

  4. Study on Influence Caused by Design and Operation Factors of Contact Aeration Tank on Effluent ATU-BOD·N-BOD Concentrations from Sedimentation Tank in Rural Sewerage Facilities with Biofilm Processes

    NASA Astrophysics Data System (ADS)

    Nakano, Takuji

    The design and operation factors on the effluent ATU-BOD·N-BOD concentrations in sedimentation tank were investigated by using observed data in the rural sewerage facilities with biofilm processes. It was found that the effluent N-BOD accounted for approximate 50 percent of the effluent BOD concentration in sedimentation tank because of the effluent ATU-BOD decrease(about 70 percent) and the effluent N-BOD increase (about 4 times) by treatment processes of contact aeration tank. It was recognized that the effluent ATU-BOD concentration in sedimentation tank was influenced by the design and operation factors such as influent ATU-BOD concentration, specific surface area of contact filter for fixed bed submerged filter, and average DO in contact aeration tank. The effluent ATU-BOD concentration in sedimentation tank was assumed to be governed by first-order function with complete-mix system of biological treatment processes. The effluent ATU-BOD concentration in sedimentation tank was found to be predicted by the empirical formula of hydraulic retention time, influent ATU-BOD concentration, specific surface area of contact filter for fixed bed submerged filter, and average DO in contact aeration tank. It was recognized that the peak effluent N-BOD concentration in sedimentation tank occurred in the around 10∼15 hour of hydraulic retention time under the influence of biological nitrification reaction and nitrogenous compound. The effluent N-BOD concentration in sedimentation tank was also influenced by the effluent SS concentration in sedimentation tank.

  5. Improving donor lung suitability: from protective strategies to ex-vivo reconditioning.

    PubMed

    Solidoro, Paolo; Schreiber, Annia; Boffini, Massimo; Braido, Fulvio; DI Marco, Fabiano

    2016-06-01

    Lung transplant is a therapeutic option for end stage lung diseases, but only a limited number of lung grafts is considered suitable for transplantation. It has been recently suggested an approach to improve and maximize donor lung suitability, namely ventilation strategies to prevent lung damage and preserve function before transplantation. In potential lung donor patients, the use of lung-protective ventilatory strategies may protect against and at least partially reverse some conditions, such as ventilator-induced lung injury, atelectasis and neurogenic pulmonary edema, resulting in improved donor organ procurement. The novelty recently proposed lies in the integration of ventilatory strategies of previous studies, using an algorithmic approach for the management of potential donors, based on their clinical response and PaO2/FiO2 ratio. This approach could be further improved by using lung ultrasound (LUS) which demonstrated to be more accurate than bedside chest radiography in detecting and distinguishing different degrees of aeration loss, and could be useful in the evaluation of alveolar recruitment following the application of PEEP or after performing any recruitment maneuver. Finally, the close future is the exploration of ex-vivo reconditioning which introduces the exciting concept of both a protective ventilation and a protective perfusion, reducing the risk of ventilation associated damage, and, on the other hand, washing out potential inflammatory cytokines by low volume high oncotic pressure perfusion, managing the risk of edema by capillary leakage. Addressing these challenges will allow more patients with end-stage lung disease access to a lung transplant. PMID:27424500

  6. Interstitial Lung Diseases

    MedlinePlus

    Interstitial lung disease is the name for a large group of diseases that inflame or scar the lungs. The inflammation and scarring make it hard to ... air is responsible for some types of interstitial lung diseases. Specific types include Black lung disease among ...

  7. Lung Cancer Screening

    MedlinePlus

    ... Cancer Treatment Small Cell Lung Cancer Treatment Lung cancer is the leading cause of cancer death in the United States. Lung cancer is ... non- skin cancer in the United States. Lung cancer is the leading cause of cancer death in men and in women. ...

  8. Ex vivo lung perfusion.

    PubMed

    Reeb, Jeremie; Cypel, Marcelo

    2016-03-01

    Lung transplantation is an established life-saving therapy for patients with end-stage lung disease. Unfortunately, greater success in lung transplantation is hindered by a shortage of lung donors and the relatively poor early-, mid-, and long-term outcomes associated with severe primary graft dysfunction. Ex vivo lung perfusion has emerged as a modern preservation technique that allows for a more accurate lung assessment and improvement in lung quality. This review outlines the: (i) rationale behind the method; (ii) techniques and protocols; (iii) Toronto ex vivo lung perfusion method; (iv) devices available; and (v) clinical experience worldwide. We also highlight the potential of ex vivo lung perfusion in leading a new era of lung preservation. PMID:26700566

  9. Epidemiology of Lung Cancer

    PubMed Central

    Ridge, Carole A.; McErlean, Aoife M.; Ginsberg, Michelle S.

    2013-01-01

    Incidence and mortality attributed to lung cancer has risen steadily since the 1930s. Efforts to improve outcomes have not only led to a greater understanding of the etiology of lung cancer, but also the histologic and molecular characteristics of individual lung tumors. This article describes this evolution by discussing the extent of the current lung cancer epidemic including contemporary incidence and mortality trends, the risk factors for development of lung cancer, and details of promising molecular targets for treatment. PMID:24436524

  10. Effect of aeration rate, moisture content and composting period on availability of copper and lead during pig manure composting.

    PubMed

    Shen, Yujun; Zhao, Lixin; Meng, Haibo; Hou, Yueqing; Zhou, Haibin; Wang, Fei; Cheng, Hongsheng; Liu, Hongbin

    2016-06-01

    Pollution by heavy metals, such as copper and lead, has become a limiting factor for the land application of faecal manures, such as pig manure. This study was conducted to investigate the influence of composting process parameters, including aeration rate, moisture content and composting period, on the distribution of heavy metal species during composting, and to select an optimal parameter for copper and lead inactivation. Results showed that the distribution ratios of exchangeable fractions of copper and lead had a bigger decrease under conditions of aeration rate, 0.1 m(3) min(-1) m(-3), an initial moisture content of 65% and composting period of 50 days. Suboptimal composting process conditions could lead to increased availability of heavy metals. Statistical analysis indicated that the aeration rate was the main factor affecting copper and lead inactivation, while the effects of moisture content and composting period were not significant. The rates of reduction of copper-exchangeable fractions and lead-exchangeable fractions were positively correlated with increased pH. The optimal parameters for reducing heavy metal bioavailability during pig manure composting were aeration rate, 0.1 m(3) min(-1) m(-3), initial moisture content, 65%, and composting period, 20 days. PMID:27067429

  11. Monitoring water transport between pores and voids in aerated gypsum using two-dimensional nuclear magnetic resonance exchange measurements

    NASA Astrophysics Data System (ADS)

    Song, Kyung-Min; Mitchell, Jonathan; Jaffel, Hamouda; Gladden, Lynn F.

    2012-03-01

    We investigate the connectivity between aeration voids (radius 200-300 µm) and pores (radius 20 µm) in aerated gypsum plaster using two-dimensional (2D) nuclear magnetic resonance T2-T2 relaxation time exchange experiments. These measurements provide an estimate of diffusive exchange rates for water molecules moving between environments differentiated by relaxation time. Aerated gypsum is a lightweight material manufactured by the inclusion of voids to reduce the bulk density. Such materials exhibit a multi-modal distribution of pore and void sizes and are associated with novel water imbibition processes. Here, we use T2-T2 exchange experiments to characterize the extent of fluid communication between the voids and pores to better understand the structure-transport relationships in these systems. In turn, this will aid the design of gypsum plasters with improved physical and mechanical properties. Utilizing an analytical model based on diffusion-driven exchange, we extract exchange times and hence diffusive length-scales, which are equivalent to the pore diameter. Overall, we conclude that the voids and pores are well connected. This confirms our previous hypothesis that water uptake occurs via capillary-driven imbibition through a continuum of voids and pores in aerated gypsum.

  12. Effects of subsurface aeration and trinexapac-ethyl application on soil microbial communities in a creeping bentgrass putting green

    USGS Publications Warehouse

    Feng, Y.; Stoeckel, D.M.; Van Santen, E.; Walker, R.H.

    2002-01-01

    The sensitivity of creeping bentgrass (Agrostis palustris Huds.) to the extreme heat found in the southeastern United States has led to the development of new greens-management methods. The purpose of this study was to examine the effects of subsurface aeration and growth regulator applications on soil microbial communities and mycorrhizal colonization rates in a creeping bentgrass putting green. Two cultivars (Crenshaw and Penncross), a growth regulator (trinexapacethyl), and subsurface aeration were evaluated in cool and warm seasons. Total bacterial counts were higher in whole (unsieved) soils than in sieved soils, indicating a richer rhizosphere soil environment. Mycorrhizal infection rates were higher in trinexapac-ethyl (TE) treated plants. High levels of hyphal colonization and relatively low arbuscule and vesicle occurrence were observed. Principal components analysis of whole-soil fatty acid methyl ester (FAME) profiles indicated that warm-season microbial populations in whole and sieved soils had similar constituents, but the populations differed in the cool season. FAME profiles did not indicate that subsurface aeration and TE application affected soil microbial community structure. This is the first reported study investigating the influences of subsurface aeration and TE application on soil microorganisms in a turfgrass putting green soil.

  13. Enhanced recovery of ammonia from swine manure anaerobic digester effluent using gas-permeable membranes and aeration

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Atmospheric ammonia pollution from livestock wastes can be reduced using gas-permeable membrane technology by converting ammonia contained in the manure into ammonium salt for use in fertilizers. In this study, gas-permeable membrane technology was enhanced using aeration combined with nitrificatio...

  14. Development and on-site field testing of the power-tube airlift aerator and chances for commercialization

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Aeration of ponds when dissolved oxygen (DO) concentrations are low is the principal management tool that allows for higher feeding rates, increased production, and decreased cost per unit fish produced. Recent research conducted at the USDA-ARS Warmwater Aquaculture Research Unit has shown that fee...

  15. Reducing Volatile Disinfection By-Products in Treated Drinking Water Using Aeration Technologies (WaterRF Report 4441)

    EPA Science Inventory

    The primary objective of this project was to evaluate cost-effective aeration technology solutions to address TTHM compliance at a water treatment plant clearwell. The project team worked closely with EPA Region 6 and the EPA Office of Research and Development (ORD) to identify a...

  16. Enhanced phosphorus removal from sewage in mesocosm-scale constructed wetland using zeolite as medium and artificial aeration.

    PubMed

    Vera, I; Araya, F; Andrés, E; Sáez, K; Vidal, G

    2014-08-01

    Phosphorus (P) contained in sewage maybe removed by mesocosm-scale constructed wetlands (MCW), although removal efficiency is only between 20% and 60%. P removal can be enhanced by increasing wetland adsorption capacity using special media, like natural zeolite, operating under aerobic conditions (oxidation-reduction potential (ORP) above +300 mV). The objective of this study was to evaluate P removal in sewage treated by MCW with artificial aeration and natural zeolite as support medium for the plants. The study compared two parallel lines of MCW: gravel and zeolite. Each line consisted in two MCW in series, where the first MCW of each line has artificial aeration. Additionally, four aeration strategies were evaluated. During the operation, the following parameters were measured in each MCW: pH, temperature, dissolved oxygen and ORP. Phosphate (PO4(-3) - P) and chemical oxygen demand (COD), five-day biological oxygen demand (BOD5), total suspended solids (TSS) and ammonium. (NH4(+) - N) were evaluated in influents and effluents. Plant growth (biomass) and proximate analysis for P content into Schoenoplectus californicus were also performed. The results showed that PO4(-3) - P removal efficiency was 70% in the zeolite medium, presenting significant differences (p < .05) with the results obtained by the gravel medium. Additionally, aeration was found to have a significant effect (p < .05) only in the gravel medium with an increase in up to 30% for PO43 - P removal. Thus, S. californicus contributed to 10-20% of P removal efficiency. PMID:24956754

  17. Evaluation of toxic effects of aeration and trichloroethylene oxidation on methanotrophic bacteria grown with different nitrogen sources

    SciTech Connect

    Chu, K.H.; Alvarez-Cohen, L.

    1999-02-01

    In this study the authors evaluated specific and nonspecific toxic effects of aeration and trichloroethylene (TCE) oxidation on methanotrophic bacteria grown with different nitrogen sources (nitrate, ammonia, and molecular nitrogen). The specific toxic effects, exerted directly on soluble methane monooxygenase (sMMO), were evaluated by comparing changes in methane uptake rates and naphthalene oxidation rates following aeration and/or TCE oxidation. Nonspecific toxic effects, defined as general cellular damage, were examined by using a combination of epifluorescent cellular stains to measure viable cell numbers based on respiratory activity and measuring formate oxidation activities following aeration and TCE transformation. Their results suggest that aeration damages predominantly sMMO rather than other general cellular components, whereas TCE oxidation exerts a broad range of toxic effects that damage both specific and nonspecific cellular functions. TCE oxidation caused sMMO-catalyzed activity and respiratory activity to decrease linearly with the amount of substrate degraded. Severe TCE oxidation toxicity resulted in total cessation of the methane, naphthalene, and formate oxidation activities and a 95% decrease in the respiratory activity of methanotrophs. The failure of cells to recover even after 7 days of incubation with methane suggests that generation of greater amounts of sMMO per cell due to nitrogen fixation may be responsible for enhanced TCE oxidation activities of nitrogen-fixing methanotrophs rather than enzymatic protection mechanisms associated with the nitrogenase enzymes.

  18. Application of airlift bioreactor for the cultivation of aerobic oleaginous yeast Rhodotorula glutinis with different aeration rates.

    PubMed

    Yen, Hong-Wei; Liu, Yi Xian

    2014-08-01

    The high cost of microbial oils produced from oleaginous microorganisms is the major obstacle to commercial production. In this study, the operation of an airlift bioreactor is examined for the cultivation of oleaginous yeast-Rhodotorula glutinis, due to the low process cost. The results suggest that the use of a high aeration rate could enhance cell growth. The maximum biomass concentration of 25.40 g/L was observed in the batch with a 2.0 vvm aeration rate. In addition, a higher aeration rate of 2.5 vvm could achieve the maximum growth rate of 0.46 g/L h, about twice the 0.22 g/L h obtained in an agitation tank. However, an increase in tank pressure instead of the aeration rate did not enhance cell growth. The operation of airlift bioreactor described in this work has the advantages of simple operation and low energy consumption, thus making it suitable for the accumulation of microbial oils. PMID:24503421

  19. Do radial oxygen loss and external aeration affect iron plaque formation and arsenic accumulation and speciation in rice?

    PubMed Central

    Wu, Chuan; Ye, Zhihong; Li, Hui; Wu, Shengchun; Deng, Dan; Zhu, Yongguan; Wong, Minghung

    2012-01-01

    Hydroponic experiments were conducted to investigate the effect of radial oxygen loss (ROL) and external aeration on iron (Fe) plaque formation, and arsenic (As) accumulation and speciation in rice (Oryza sativa L.). The data showed that there were significant correlations between ROL and Fe concentrations in Fe plaque produced on different genotypes of rice. There were also significant differences in the amounts of Fe plaque formed between different genotypes in different positions of roots and under different aeration conditions (aerated, normal, and stagnant treatments). In aerated treatments, rice tended to have a higher Fe plaque formation than in a stagnant solution, with the greatest formation at the root tip decreasing with increasing distances away, in accordance with a trend of spatial ROL. Genotypes with higher rates of ROL induced higher degrees of Fe plaque formation. Plaques sequestered As on rice roots, with arsenate almost double that with arsenite, leading to decreased As accumulation in both roots and shoots. The major As species detected in roots and shoots was arsenite, ranging from 34 to 78% of the total As in the different treatments and genotypes. These results contribute to our understanding of genotypic differences in As uptake by rice and the mechanisms causing rice genotypes with higher ROL to show lower overall As accumulation. PMID:22345639

  20. Removal of COD and nitrogen from animal food plant wastewater in an intermittently-aerated structured-bed reactor.

    PubMed

    Wosiack, Priscila Arcoverde; Lopes, Deize Dias; Rissato Zamariolli Damianovic, Márcia Helena; Foresti, Eugenio; Granato, Daniel; Barana, Ana Cláudia

    2015-05-01

    This study evaluated the performance of a continuous flow structured-bed reactor in the simultaneous removal of total nitrogen (TN) and chemical oxygen demand (COD) in the effluent from an animal food plant. The reactor had an intermittent aeration system; hydraulic retention time (HRT) of one day; temperature of 30 °C; and recirculation ratio of five times the flow. An experimental central composite rotational delineation (CCRD) type design was used to define the aeration conditions and nitrogen load (factors) to be studied. Response surface methodology was used to analyse the influence of the factors above the results, the removal of TN and COD. It was observed that the aeration factor showed the greatest significance for the results and that the affluent TKN concentration did not have a significant effect, at a 95% level of confidence, on COD removal. Throughout the experiment, the COD/N ratio remained between 3.2 and 3.8. The best results for COD and TN removal, 80% and 88%, respectively, were obtained with 158 min of aeration on a cycle of 180 min and 255 mg L(-1) of Total Kjeldahl Nitrogen (TKN) in the substrate. PMID:25725386

  1. Framework for Energy Neutral Treatment for the 21st Century Through Energy Efficient Aeration (WERF Report INFR2R12)

    EPA Science Inventory

    Aeration is commonly identified as the most significant energy use in the treatment of wastewater and therefore garners significant focus in reducing energy use in the ultimate aspirational goal of achieving net energy neutrality for water resource recovery. This research establi...

  2. Aeration and mass transfer optimization in a rectangular airlift loop photobioreactor for the production of microalgae.

    PubMed

    Guo, Xin; Yao, Lishan; Huang, Qingshan

    2015-08-01

    Effects of superficial gas velocity and top clearance on gas holdup, liquid circulation velocity, mixing time, and mass transfer coefficient are investigated in a new airlift loop photobioreactor (PBR), and empirical models for its rational control and scale-up are proposed. In addition, the impact of top clearance on hydrodynamics, especially on the gas holdup in the internal airlift loop reactor, is clarified; a novel volume expansion technique is developed to determine the low gas holdup in the PBR. Moreover, a model strain of Chlorella vulgaris is cultivated in the PBR and the volumetric power is analyzed with a classic model, and then the aeration is optimized. It shows that the designed PBR, a cost-effective reactor, is promising for the mass cultivation of microalgae. PMID:25958141

  3. Influence of water cavitation peening with aeration on fatigue behaviour of SAE1045 steel

    NASA Astrophysics Data System (ADS)

    Han, B.; Ju, D. Y.; Jia, W. P.

    2007-10-01

    Water cavitation peening (WCP) with aeration is a recent potential method in the surface enhancement techniques. In this method, a ventilation nozzle is adopted to improve the process capability of WCP by increasing the impact pressure, which is induced by the bubble collapse on the surface of components in the similar way as conventional shot peening. In this paper, fatigue tests were conducted on the both-edge-notched flat tensile specimens to assess the influences of WCP on fatigue behaviour of SAE1045 steel. The notched specimens were treated by WCP, and the compressive residual stress distributions in the superficial layer were measured by X-ray diffraction method. The tension-tension ( R = Smin/ Smax = 0.1, f = 10 Hz) fatigue tests and the fracture surfaces observation by scan electron microscopy (SEM) were conducted. The experimental results show that WCP can improve the fatigue life by inducing the residual compressive stress in the superficial layer of mechanical components.

  4. Effect of aeration during cell growth on ketone reactions by immobilized yeast.

    PubMed

    Gervais, T R; Carta, G; Gainer, J L

    2000-01-01

    The effect of aeration during cell growth on the subsequent reduction of 2-hexanone and 2-octanone by yeast cells entrapped in calcium alginate beads was studied. The reactions were conducted using 2-propanol as a sacrificial substrate to regenerate the cofactor NAD(H), and a mixture of (S)- and (R)-alcohols was produced. The use of strictly aerobic conditions when growing the cells resulted in the highest initial reaction rates, as well as the production of only a single product (i.e., the enantiomeric excess of the (S)-alcohols was 1.0). However, initial reaction rates decreased proportionally with fermentation time regardless of whether the yeast were grown aerobically or under both aerobic and anaerobic conditions. The data also suggest that it is the aerobic (or anaerobic) condition, rather than the cell growth phase, which is responsible for the results seen. PMID:10753445

  5. Modelling nitrogen and carbon interactions in composting of animal manure in naturally aerated piles.

    PubMed

    Oudart, D; Robin, P; Paillat, J M; Paul, E

    2015-12-01

    Composting animal manure with natural aeration is a low-cost and low-energy process that can improve nitrogen recycling in millions of farms world-wide. Modelling can decrease the cost of choosing the best options for solid manure management in order to decrease the risk of loss of fertilizer value and ammonia emission. Semi-empirical models are suitable, considering the scarce data available in farm situations. Eleven static piles of pig or poultry manure were monitored to identify the main processes governing nitrogen transformations and losses. A new model was implemented to represent these processes in a pile considered as homogeneous. The model is based on four modules: biodegradation, nitrogen transformations and volatilization, thermal exchanges, and free air space evolution. When necessary, the parameters were calibrated with the data set. The results showed that microbial growth could reduce ammonia volatilization. Greatest nitrogen conservation is achieved when microbial growth was limited by nitrogen availability. PMID:26403389

  6. Effects of aeration on formation and localization of the acetyl coenzyme A synthetases of Saccharomyces cerevisiae

    NASA Technical Reports Server (NTRS)

    Klein, H. P.; Jahnke, L.

    1979-01-01

    Previous studies on the yeast Saccharomyces cerevisiae have shown that two different forms of the enzyme acetyl coenzyme A synthetase (ACS) are present, depending on the conditions under which the cells are grown. The paper evaluates the usefulness of a method designed to assay both synthetases simultaneously in yeast homogenates. The data presented confirm the possibility of simultaneous detection and estimation of the amount of both ACSs of S. cerevisiae in crude homogenates of this strain, making possible the study of physiological factors involved in the formation of these isoenzymes. One important factor for specifying which of the two enzymes is found in these yeast cells is the presence or absence of oxygen in their environment. Aeration not only affects the ratio of the two ACSs but also appears to affect the cellular distribution of these enzymes. Most of the data presented suggest the possibility that the nonaerobic ACS may serve as a precursor to the aerobic form.

  7. Engineering aspects of a mixed methanotrophic culture in a membrane-aerated biofilm reactor.

    PubMed

    Casey, E; Rishell, S; Glennon, B; Hamer, G

    2004-01-01

    Methanotrophic biodegradation using the membrane-aerated biofilm reactor (MABR) is a technology offering several advantages over both conventional biofilm reactors and suspended-cell processes. In this study the oxidation efficiency of a methanotrophic biofilm in a 1.5 litre MABR was investigated. Measurements of oxygen and methane uptake rates together with biofilm thickness were taken for developing biofilms. It was found that the specific rate of metabolic activity of the biofilm was unusually high as determined by the methane and oxygen uptake rates. Microbial activity stratification was evident and the location of stratified layers of oxygen consuming components of the consortium could be manipulated via the intra-membrane oxygen pressure. PMID:15303749

  8. Removal of diclofenac from surface water by electron beam irradiation combined with a biological aerated filter

    NASA Astrophysics Data System (ADS)

    He, Shijun; Wang, Jianlong; Ye, Longfei; Zhang, Youxue; Yu, Jiang

    2014-12-01

    The degradation of DCF was investigated in aqueous solution by using electron beam (EB) technology. When the initial concentration was between 10 and 40 mg/L, almost 100% of the DCF was degraded at a dose of 0.5 kGy. However, only about 6.5% of DCF was mineralized even at 2 kGy according to total organic carbon (TOC) measurements. A combined process of EB and biological aerated filter (BAF) was therefore developed to enhance the treatment of DCF contaminated surface water. The effluent quality of combined process was substantially improved by EB pretreatment due to the degradation of DCF and related intermediates. Both irradiation and biological treatment reduced the toxicity of the treated water. The experimental results showed that EB is effective for removing DCF from artificial aqueous solution and real surface water.

  9. Maximizing the xylitol production from sugar cane bagasse hydrolysate by controlling the aeration rate

    SciTech Connect

    Silva, S.S.; Ribeiro, J.D.; Felipe, M.G.A.; Vitolo, M.

    1997-12-31

    Batch fermentations of sugar cane bagasse hemicellulosic hydrolysate treated for removing the inhibitors of the fermentation were performed by Candida guilliermondii FTI 20037 for xylitol production. The fermentative parameters agitation and aeration rate were studied aiming the maximization of xylitol production from this agroindustrial residue. The maximal xylitol volumetric productivity (0.87 g/L {center_dot} h) and yield (0.67 g/g) were attained at 400/min and 0.45 v.v.m. (K{sub L}a 27/h). According to the results, a suitable control of the oxygen input permitting the xylitol formation from sugar cane bagasse hydrolysate is required for the development of an efficient fermentation process for large-scale applications. 20 refs., 2 figs.

  10. Nitrogen elimination mechanisms in an organic media aerated biofilter treating pig manure.

    PubMed

    Garzón-Zúñiga, M; Lessard, P; Aubry, G; Buelna, G

    2005-04-01

    Biofilters using organic media are known to procure efficient treatment for different types of wastewater, but the nitrogen removal pathways implied are still not well understood. In this study, a lab-scale aerated biofilter using peat and treating pig manure was operated for 180 days, in order to quantify the nitrogen transformations occurring in it. It was shown that stripping was important during the start-up, until nitrification took place. Simultaneous nitrification and denitrification, proved by N2 production, became the principal mechanism after some time. The production of N2O did not seem to come only from heterotrophic denitrification, but also from chemodenitrification and autotrophic denitrification. It has also been found that part of the influent nitrogen was retained in the system during the first 150 days, due to filtration, sorption and assimilation. During the last periods of operation, the nitrogen previously retained has been used by microorganisms, leading to an excessive N2 discharge. PMID:15906487

  11. Winery wastewater treatment by a combined process: long term aerated storage and Fenton's reagent.

    PubMed

    Lucas, Marco S; Mouta, Maria; Pirra, António; Peres, José A

    2009-01-01

    The degradation of the organic pollutants present in winery wastewater was carried out by the combination of two successive steps: an aerobic biological process followed by a chemical oxidation process using Fenton's reagent. The main goal of this study was to evaluate the temporal characteristics of solids and chemical oxygen demand (COD) present in winery wastewater in a long term aerated storage bioreactor. The performance of different air dosage daily supplied to the biologic reactor, in laboratory and pilot scale, were examined. The long term hydraulic retention time, 11 weeks, contributed remarkably to the reduction of COD (about 90%) and the combination with the Fenton's reagent led to a high overall COD reduction that reached 99.5% when the mass ratio (R = H(2)O(2)/COD) used was equal to 2.5, maintaining constant the molar ratio H(2)O(2)/Fe(2+)=15. PMID:19700849

  12. In situ activity recovery of aging biofilm in biological aerated filter: Surfactants treatment and mechanisms study.

    PubMed

    Yu, Qisheng; Huang, Hui; Ren, Hongqiang; Ding, Lili; Geng, Jinju

    2016-11-01

    In situ activity recovery of aging biofilm in the biological aerated filter (BAF) is an important but underappreciated problem. Lab-scaled BAFs were established in this study and three kinds of surfactants containing sodium dodecyl sulfate (SDS), sodium dodecyl benzene sulfonate (SDBS) and rhamnolipid were employed. Multiple indicators including effluent qualities, dissolved organic matters, biofilm physiology and morphology characteristics were investigated to explore the mechanisms. Results showed that removal rates of effluent COD in test groups significantly recovered to the level before aging. Compared with the control, effluent in SDBS and rhamnolipid-treated groups obtained more protein-like and humic-like substances, respectively. Furthermore, great live cell ratio, smooth surface and low adhesion force of biofilm were observed after rhamnolipid treatment, which was in consistent with good effluent qualities in the same group. This is the first report of applying rhamnolipid for in situ activity recovery of aging biofilm in bioreactors. PMID:27513646

  13. Application of automatic image analysis for the investigation of autoclaved aerated concrete structure

    SciTech Connect

    Petrov, I.; Schlegel, E. . Inst. fuer Silikattechnik)

    1994-01-01

    Autoclaved aerated concrete (AAC) is formed from small-grained mixtures of raw materials and Al-powder as an air entraining agent. Owing to its high porosity AAC has a low bulk density which leads to very good heat insulating qualities. Automatic image analysis in connection with stereology and stochastic geometry was used to describe the size distribution of air pores in autoclaved concrete. The experiments were carried out an AAC samples with extremely different bulk densities and compressive strengths. The assumption of an elliptic shape of pores leads to an unambiguous characterization of structure by bi-histograms. It will be possible to calculate the spatial pore size distribution by these histograms, if the pores are assumed as being spheroids. A marked point field model and the pair correlation function g[sub a](r) were used to describe the pore structure.

  14. A combined system of microbial fuel cell and intermittently aerated biological filter for energy self-sufficient wastewater treatment.

    PubMed

    Dong, Yue; Feng, Yujie; Qu, Youpeng; Du, Yue; Zhou, Xiangtong; Liu, Jia

    2015-01-01

    Energy self-sufficiency is a highly desirable goal of sustainable wastewater treatment. Herein, a combined system of a microbial fuel cell and an intermittently aerated biological filter (MFC-IABF) was designed and operated in an energy self-sufficient manner. The system was fed with synthetic wastewater (COD = 1000 mg L(-1)) in continuous mode for more than 3 months at room temperature (~25 °C). Voltage output was increased to 5 ± 0.4 V using a capacitor-based circuit. The MFC produced electricity to power the pumping and aeration systems in IABF, concomitantly removing COD. The IABF operating under an intermittent aeration mode (aeration rate 1000 ± 80 mL h(-1)) removed the residual nutrients and improved the water quality at HRT = 7.2 h. This two-stage combined system obtained 93.9% SCOD removal and 91.7% TCOD removal (effluent SCOD = 61 mg L(-1), TCOD = 82.8 mg L(-1)). Energy analysis indicated that the MFC unit produced sufficient energy (0.27 kWh m(-3)) to support the pumping system (0.014 kWh m(-3)) and aeration system (0.22 kWh m(-3)). These results demonstrated that the combined MFC-IABF system could be operated in an energy self-sufficient manner, resulting to high-quality effluent. PMID:26666392

  15. A combined system of microbial fuel cell and intermittently aerated biological filter for energy self-sufficient wastewater treatment

    PubMed Central

    Dong, Yue; Feng, Yujie; Qu, Youpeng; Du, Yue; Zhou, Xiangtong; Liu, Jia

    2015-01-01

    Energy self-sufficiency is a highly desirable goal of sustainable wastewater treatment. Herein, a combined system of a microbial fuel cell and an intermittently aerated biological filter (MFC-IABF) was designed and operated in an energy self-sufficient manner. The system was fed with synthetic wastewater (COD = 1000 mg L−1) in continuous mode for more than 3 months at room temperature (~25 °C). Voltage output was increased to 5 ± 0.4 V using a capacitor-based circuit. The MFC produced electricity to power the pumping and aeration systems in IABF, concomitantly removing COD. The IABF operating under an intermittent aeration mode (aeration rate 1000 ± 80 mL h−1) removed the residual nutrients and improved the water quality at HRT = 7.2 h. This two-stage combined system obtained 93.9% SCOD removal and 91.7% TCOD removal (effluent SCOD = 61 mg L−1, TCOD = 82.8 mg L−1). Energy analysis indicated that the MFC unit produced sufficient energy (0.27 kWh m−3) to support the pumping system (0.014 kWh m−3) and aeration system (0.22 kWh m−3). These results demonstrated that the combined MFC-IABF system could be operated in an energy self-sufficient manner, resulting to high-quality effluent. PMID:26666392

  16. Analysing the effects of the aeration pattern and residual ammonium concentration in a partial nitritation-anammox process.

    PubMed

    Corbalá-Robles, Luis; Picioreanu, Cristian; van Loosdrecht, Mark C M; Pérez, Julio

    2016-01-01

    A mathematical model was used to evaluate the effect of the aeration pattern and ammonium concentration in a partial nitritation-anammox sequencing batch reactor with granular and flocculent sludge. In the tested conditions, model results indicate that most of the aerobic ammonium oxidation potential would occur in the bulk liquid, with 70% of the ammonium-oxidizing bacteria (AOB) biomass in suspension rather than in granules. The simulated granular sludge consisted predominantly of anammox bacteria with AOB present in the outer layer of the granule (50 μm AOB layer, accounting for 3% of the granule weight). Simulation results indicated that when granules do not contain any AOB, the amount of granular biomass required to achieve the same level of nitrogen removal would strongly increase (in the simulated conditions, by a factor of three) due to anammox inhibition by oxygen. This underlines the importance of a small fraction of AOB present in the granular anammox sludge. The aeration pattern had an important impact on the nitrogen removal: a better performance was suggested for continuous aeration (90% N-removal) than for intermittent aeration (68-84% N-removal). Anammox inhibition during the periods of high oxygen concentration was identified as the main reason for the lower nitrogen removal in the intermittently aerated system. With increasing oxygen concentration, a higher residual (effluent) ammonium concentration was needed to assure nitrite-oxidizing bacteria repression in the system. This study contributes to further understand the complexity of a reactor with both granular and flocculent sludge and the impact of operation conditions on reactor performance. PMID:26235726

  17. Mechanisms of ammonium transformation and loss in intermittently aerated leachfield soil.

    PubMed

    Richard, John T; Potts, David A; Amador, José A

    2014-11-01

    Optimization of N removal in soil-based wastewater treatment systems requires an understanding of the microbial processes involved in N transformations. We examined the fate of NH in intermittently aerated leachfield mesocosms over a 24-h period. Septic tank effluent (STE) was amended with NHCl to help determine N speciation and distribution in drainage water, soil, and headspace gases. Our results show that 5.7% of the N was found in soil, 10.0% in drainage water, and 84.3% in the gas pool. Ammonium accounted for 41.7% of the soil N pool, followed by NO (29.2%), organic N (21.7%), and microbial biomass N (7.5%). In drainage water, NO constituted ∼80% of the N pool, whereas NH was absent from this pool. Nitrous oxide was the dominant form of N in the gas phase 6 h after addition of NH-amended STE to the mesocosms, after which its mass declined exponentially; by contrast, the mass of N was initially low but increased linearly with time to become the dominant form of N after 24 h. Analysis based on the isotopic enrichment of NO and N indicates that nitrification contributed 98.8 and 23.1% of the NO flux after 6 and 24 h, respectively. Our results show that gaseous losses are the main mechanism for NH removal from wastewater in intermittently aerated soil. In addition, nitrification, which is generally not considered a significant pathway for N loss in soil-based wastewater treatment, is an important source process for NO. PMID:25602229

  18. Lung cancer among Navajo uranium miners

    SciTech Connect

    Gottlieb, L.S.; Husen, L.A.

    1982-04-01

    Lung cancer has been a rare disease among the Indians of the southwestern United States. However, the advent of uranium mining in the area has been associated with an increased incidence of lung cancer among Navajo uranium miners. This study centers on Navajo men with lung cancer who were admitted to the hospital from February 1965 to May 1979. Of a total of 17 patients with lung cancer, 16 were uranium miners, and one was a nonminer. The mean value of cumulative radon exposure for this group was 1139.5 working level months (WLMs). The predominant cancer type was the small cell undifferentiated category (62.5 percent). The low frequency of cigarette smoking in this group supports the view that radiation is the primary cause of lung cancer among uranium miners and that cigarette smoking acts as a promoting agent.

  19. Effect of aeration rate on the emission of N2O in anoxic-aerobic sequencing batch reactors (A/O SBRs).

    PubMed

    Hu, Zhen; Zhang, Jian; Li, Shanping; Xie, Huijun; Wang, Jinhe; Zhang, Tingting; Li, Yiran; Zhang, Huayong

    2010-05-01

    Nitrous oxide (N(2)O) is a significant greenhouse gas, and biological nitrogen removal systems have been shown to be a significant N(2)O source. To evaluate the control parameters for N(2)O emission in the wastewater treatment process, N(2)O emissions were compared in the activated sludge from anoxic-aerobic sequencing batch reactors (A/O SBRs) acclimated under different aeration rates, and fed with synthetic wastewater. Results showed that a higher aeration rate led to a smaller N(2)O emission, while reactors acclimated under mild aeration performed the best in terms of nitrogen removal efficiency. Most of the N(2)O was produced during the aerobic phase, regardless of the aeration rate. Trace studies showed that incomplete denitrification appeared to be the major process responsible for high N(2)O emission at a low aeration rate (Run 1), while incomplete nitrification was the reason for N(2)O emission at a higher aeration rate (Run 2 and Run 3). For enhancing the efficiency of nitrogen removal while lowering energy consumption and reducing N(2)O emission, the optimal aeration rate would be 2.7 L(air)/(L(reactor) . h), in terms of the synthetic wastewater used. PMID:20347772

  20. Epidemiology of Lung Cancer

    PubMed Central

    Brock, Malcolm V.; Ford, Jean G.; Samet, Jonathan M.; Spivack, Simon D.

    2013-01-01

    Background: Ever since a lung cancer epidemic emerged in the mid-1900s, the epidemiology of lung cancer has been intensively investigated to characterize its causes and patterns of occurrence. This report summarizes the key findings of this research. Methods: A detailed literature search provided the basis for a narrative review, identifying and summarizing key reports on population patterns and factors that affect lung cancer risk. Results: Established environmental risk factors for lung cancer include smoking cigarettes and other tobacco products and exposure to secondhand tobacco smoke, occupational lung carcinogens, radiation, and indoor and outdoor air pollution. Cigarette smoking is the predominant cause of lung cancer and the leading worldwide cause of cancer death. Smoking prevalence in developing nations has increased, starting new lung cancer epidemics in these nations. A positive family history and acquired lung disease are examples of host factors that are clinically useful risk indicators. Risk prediction models based on lung cancer risk factors have been developed, but further refinement is needed to provide clinically useful risk stratification. Promising biomarkers of lung cancer risk and early detection have been identified, but none are ready for broad clinical application. Conclusions: Almost all lung cancer deaths are caused by cigarette smoking, underscoring the need for ongoing efforts at tobacco control throughout the world. Further research is needed into the reasons underlying lung cancer disparities, the causes of lung cancer in never smokers, the potential role of HIV in lung carcinogenesis, and the development of biomarkers. PMID:23649439

  1. Atmospheric pollution and lung cancer.

    PubMed Central

    Doll, R

    1978-01-01

    Lung cancer is consistently more common in urban areas than in rural. The excess cannot be accounted for by specific occupational hazards but some of it might be due to the presence of carcinogens in urban air. The excess cannot be wholly due to such agents, because the excess in nonsmokers is small and variable. Cigarette consumption has also been greater in urban areas, but it is difficult to estimate how much of the excess it can account for. Occupational studies confirm that pollutants present in town air are capable of causing lung cancer in man and suggest that the pollutants and cigarette smoke act synergistically. The trends in the mortality from lung cancer in young and middle-aged men in England and Wales provide uncertain evidence but support the belief that atmospheric pollution has contributed to the production of the disease. In the absence of cigarette smoking, the combined effect of all atmospheric carcinogens is not responsible for more than about 5 cases of lung cancer per 100,000 persons per year in European populations. PMID:648488

  2. Endocytosis, oxidative stress and IL-8 expression in human lung epithelial cells upon treatment with fine and ultrafine TiO{sub 2}: Role of the specific surface area and of surface methylation of the particles

    SciTech Connect

    Singh, Seema |; Shi, Tingming |; Duffin, Rodger |; Albrecht, Catrin; Berlo, Damien van; Hoehr, Doris; Fubini, Bice; Martra, Gianmario; Fenoglio, Ivana; Borm, Paul J.A. |; Schins, Roel P.F. . E-mail: roel.schins@uni-duesseldorf.de

    2007-07-15

    Inhaled ultrafine particles show considerably stronger pulmonary inflammatory effects when tested at equal mass dose with their fine counterparts. However, the responsible mechanisms are not yet fully understood. We investigated the role of particle size and surface chemistry in initiating pro-inflammatory effects in vitro in A549 human lung epithelial cells on treatment with different model TiO{sub 2} particles. Two samples of TiO{sub 2}, i.e. fine (40-300 nm) and ultrafine (20-80 nm) were tested in their native forms as well as upon surface methylation, as was confirmed by Fourier transformed infrared spectroscopy. Radical generation during cell treatment was determined by electron paramagnetic resonance with 5,5-dimethyl-1-pyrroline-N-oxide or 4-hydroxy-2,2,6,6-tetramethylpiperidine-1-oxyl. Interleukin-8 mRNA expression/release was determined by RT-PCR and ELISA, whereas particle uptake was evaluated by transmission electron microscopy. TiO{sub 2} particles were rapidly taken up by the cells, generally as membrane bound aggregates and large intracellular aggregates in vesicles, vacuoles and lamellar bodies. Aggregate size tended to be smaller for the ultrafine samples and was also smaller for methylated fine TiO{sub 2} when compared to non-methylated fine TiO{sub 2}. No particles were observed inside nuclei or any other vital organelle. Both ultrafine TiO{sub 2} samples but not their fine counterparts elicited significantly stronger oxidant generation and IL-8 release, despite their aggregation state and irrespective of their methylation. The present data indicate that ultrafine TiO{sub 2}, even as aggregates/agglomerates, can trigger inflammatory responses that appear to be driven by their large surface area. Furthermore, our results indicate that these effects result from oxidants generated during particle-cell interactions through a yet to be elucidated mechanism(s)

  3. Epidemiology of Lung Cancer.

    PubMed

    Mao, Yousheng; Yang, Ding; He, Jie; Krasna, Mark J

    2016-07-01

    Lung cancer has been transformed from a rare disease into a global problem and public health issue. The etiologic factors of lung cancer become more complex along with industrialization, urbanization, and environmental pollution around the world. Currently, the control of lung cancer has attracted worldwide attention. Studies on the epidemiologic characteristics of lung cancer and its relative risk factors have played an important role in the tertiary prevention of lung cancer and in exploring new ways of diagnosis and treatment. This article reviews the current evolution of the epidemiology of lung cancer. PMID:27261907

  4. Comparison between lab- and full-scale applications of in situ aeration of an old landfill and assessment of long-term emission development after completion

    SciTech Connect

    Hrad, Marlies; Gamperling, Oliver; Huber-Humer, Marion

    2013-10-15

    Highlights: ► Current data on in situ aeration effects from the first Austrian full-scale case study. ► Data on lasting waste stabilisation after aeration completion. ► Information on the transferability of results from lab- to full-scale aeration. - Abstract: Sustainable landfilling has become a fundamental objective in many modern waste management concepts. In this context, the in situ aeration of landfills has been recognised for its potential to convert conventional anaerobic landfills into biological stabilised state, whereby both current and potential (long-term) emissions of the landfilled waste are mitigated. In recent years, different in situ aeration concepts have been successfully applied in Europe, North America and Asia, all pursuing different objectives and strategies. In Austria, the first full-scale application of in situ landfill aeration by means of low pressure air injection and simultaneous off-gas collection and treatment was implemented on an old, small municipal solid waste (MSW) landfill (2.6 ha) in autumn 2007. Complementary laboratory investigations were conducted with waste samples taken from the landfill site in order to provide more information on the transferability of the results from lab- to full-scale aeration measures. In addition, long-term emission development of the stabilised waste after aeration completion was assessed in an ongoing laboratory experiment. Although the initial waste material was described as mostly stable in terms of the biological parameters gas generation potential over 21 days (GP{sub 21}) and respiration activity over 4 days (RA{sub 4}), the lab-scale experiments indicated that aeration, which led to a significant improvement of leachate quality, was accompanied by further measurable changes in the solid waste material under optimised conditions. Even 75 weeks after aeration completion the leachate, as well as gaseous emissions from the stabilised waste material, remained low and stayed below the

  5. Strategies for Whole Lung Tissue Engineering

    PubMed Central

    Calle, Elizabeth A.; Ghaedi, Mahboobe; Sundaram, Sumati; Sivarapatna, Amogh; Tseng, Michelle K.

    2014-01-01

    Recent work has demonstrated the feasibility of using decellularized lung extracellular matrix scaffolds to support the engineering of functional lung tissue in vitro. Rendered acellular through the use of detergents and other reagents, the scaffolds are mounted in organ-specific bioreactors where cells in the scaffold are provided with nutrients and appropriate mechanical stimuli such as ventilation and perfusion. Though initial studies are encouraging, a great deal remains to be done to advance the field and transition from rodent lungs to whole human tissue engineered lungs. To do so, a variety of hurdles must be overcome. In particular, a reliable source of human-sized scaffolds, as well as a method of terminal sterilization of scaffolds, must be identified. Continued research in lung cell and developmental biology will hopefully help identify the number and types of cells that will be required to regenerate functional lung tissue. Finally, bioreactor designs must be improved in order to provide more precise ventilation stimuli and vascular perfusion in order to avoid injury to or death of the cells cultivated within the scaffold. Ultimately, the success of efforts to engineer a functional lung in vitro will critically depend on the ability to create a fully endothelialized vascular network that provides sufficient barrier function and alveolar-capillary surface area to exchange gas at rates compatible with healthy lung function. PMID:24691527

  6. Strategies for whole lung tissue engineering.

    PubMed

    Calle, Elizabeth A; Ghaedi, Mahboobe; Sundaram, Sumati; Sivarapatna, Amogh; Tseng, Michelle K; Niklason, Laura E

    2014-05-01

    Recent work has demonstrated the feasibility of using decellularized lung extracellular matrix scaffolds to support the engineering of functional lung tissue in vitro. Rendered acellular through the use of detergents and other reagents, the scaffolds are mounted in organ-specific bioreactors where cells in the scaffold are provided with nutrients and appropriate mechanical stimuli such as ventilation and perfusion. Though initial studies are encouraging, a great deal remains to be done to advance the field and transition from rodent lungs to whole human tissue engineered lungs. To do so, a variety of hurdles must be overcome. In particular, a reliable source of human-sized scaffolds, as well as a method of terminal sterilization of scaffolds, must be identified. Continued research in lung cell and developmental biology will hopefully help identify the number and types of cells that will be required to regenerate functional lung tissue. Finally, bioreactor designs must be improved in order to provide more precise ventilation stimuli and vascular perfusion in order to avoid injury to or death of the cells cultivated within the scaffold. Ultimately, the success of efforts to engineer a functional lung in vitro will critically depend on the ability to create a fully endothelialized vascular network that provides sufficient barrier function and alveolar-capillary surface area to exchange gas at rates compatible with healthy lung function. PMID:24691527

  7. Immune checkpoint blockade in lung cancer.

    PubMed

    Somasundaram, Aswin; Socinski, Mark A; Villaruz, Liza C

    2016-08-01

    Immunotherapy has revolutionized the therapeutic landscape of advanced lung cancer. The adaptive immune system has developed a sophisticated method of tumor growth control, but T-cell activation is regulated by various checkpoints. Blockade of the immune checkpoints with therapies targeting the PD-1 pathway, such as nivolumab and pembrolizumab, has been validated as a therapeutic approach in non-small cell lung cancer. Newer therapies and novel combinations are also being evaluated, and the use of biomarkers in conjunction with these drugs is an area of active investigation. This review summarizes the current evidence for the efficacy and safety of the above approaches in the treatment of lung cancer. PMID:27585231

  8. Combination of Successive Alkalinity Producing System (SAPS) and Aeration for Passive Treatment of Highly Acidic Mine Drainage

    NASA Astrophysics Data System (ADS)

    Oh, C.; Ji, S.

    2015-12-01

    Passive treatment system has been widely used for remediation of mine drainage since its advantage of low installation and maintenance cost. The system, however, has also a disadvantage in assuring remediation and management efficiency if the drainage is highly acidic mine drainage. To remediate acid mine drainage (AMD) especially showing high acidity, passive treatment system which consists of successive alkalinity producing system (SAPS) and subsequent aeration pond was proposed and its mechanisms and efficiency was evaluated in this research. Target AMD was obtained from Waryong coal mine and showed typical characteristics of AMD having high metal concentration and low pH (acidity > 300 mg/L as CaCO3). Four experimental cases were conducted; untreated, treated with SAPS, treated with aeration, treated with SAPS and aeration to compare role and mechanism of each unit. Between organic matter and limestone layer which constitute SAPS, the former eliminated most of Fe(III) and Al in the AMD so that the latter was kept from being clogged by precipitates. Net acidity of the AMD rapidly decreased by supplement of alkalinity at the limestone layer. A primary function of SAPS, producing alkalinity constantly without clogging, was attained due to addition a portion of limestone particle into the organic matter layer. The discharge from SAPS had low ORP and DO values because of an anaerobic environment formed at the organic matter layer although its alkalinity was increased. This water quality was unfavorable for Fe(II) to be oxidized. Installation of aeration pond after SAPS, therefore, could be effective way of enhancing oxidation rate of Fe(II). Among the experimental cases, the combination of SAPS and aeration pond was only able to remediate the AMD. This concluded that to remediate highly acidic mine drainage with passive treatment system, three critical conditions were required; pre-precipitation of Fe(III) and Al at organic matter layer in SAPS, constant alkalinity

  9. Odorous gaseous emissions as influence by process condition for the forced aeration composting of pig slaughterhouse sludge

    SciTech Connect

    Blazy, V.; Guardia, A. de; Benoist, J.C; Daumoin, M.; Lemasle, M.; Wolbert, D.; Barrington, S.

    2014-07-15

    Highlights: • The gaseous emissions produced by various composting process conditions were characterized and quantified. • Nine compounds were potentially odorous: TMA, NH{sub 3}, 2-pentanone, 1-propanol-2-methyl, acetophenone and sulphur forms. • The tested composting process conditions reduced odour emissions by a factor of 5–10. • A reduction of 10{sup 5} to 10{sup 6} is required to reach an odour threshold limit at peak event emissions. • Both aeration rate and bulking agent had the most impact on reducing odour emissions. - Abstract: Compost sustainability requires a better control of its gaseous emissions responsible for several impacts including odours. Indeed, composting odours have stopped the operation of many platforms and prevented the installation of others. Accordingly, present technologies collecting and treating gases emitted from composting are not satisfactory and alternative solutions must be found. Thus, the aim of this paper was to study the influence of composting process conditions on gaseous emissions. Pig slaughterhouse sludge mixed with wood chips was composted under forced aeration in 300 L laboratory reactors. The process conditions studied were: aeration rate of 1.68, 4.03, 6.22, 9.80 and 13.44 L/h/kg of wet sludge; incorporation ratio of 0.55, 0.83 and 1.1 (kg of wet wood chips/kg of wet sludge), and; bulking agent particles size of <10, 10 < 20 and 20 < 30 mm. Out-going gases were sampled every 2 days and their composition was analysed using gas chromatography coupled with mass spectrometry (GC–MS). Fifty-nine compounds were identified and quantified. Dividing the cumulated mass production over 30 days of composting, by odour threshold, 9 compounds were identified as main potential odour contributors: hydrogen sulphide, trimethylamine, ammonia, 2-pentanone, 1-propanol-2-methyl, dimethyl sulphide, dimethyl disulphide, dimethyl trisulphide and acetophenone. Five gaseous compounds were correlated with both aeration rate and

  10. Open lung biopsy

    MedlinePlus

    ... of different conditions, such as: Rheumatoid lung disease Sarcoidosis Wegener granulomatosis Risks There is a possibility of ... fibrous Mesothelioma - malignant Pulmonary tuberculosis Rheumatoid lung disease Sarcoidosis Simple pulmonary eosinophilia Viral pneumonia X-ray Update ...

  11. Lung Diseases and Conditions

    MedlinePlus

    ... Share this page from the NHLBI on Twitter. Lung Diseases and Conditions Breathing is a complex process. ... your bronchial tubes ( bronchitis ) or deep in your lungs ( pneumonia ). These infections cause a buildup of mucus ...

  12. Ex vivo lung perfusion.

    PubMed

    Machuca, Tiago N; Cypel, Marcelo

    2014-08-01

    Lung transplantation (LTx) is an established treatment option for eligible patients with end-stage lung disease. Nevertheless, the imbalance between suitable donor lungs available and the increasing number of patients considered for LTx reflects in considerable waitlist mortality. Among potential alternatives to address this issue, ex vivo lung perfusion (EVLP) has emerged as a modern preservation technique that allows for more accurate lung assessment and also improvement of lung function. Its application in high-risk donor lungs has been successful and resulted in safe expansion of the donor pool. This article will: (I) review the technical details of EVLP; (II) the rationale behind the method; (III) report the worldwide clinical experience with the EVLP, including the Toronto technique and others; (IV) finally, discuss the growing literature on EVLP application for donation after cardiac death (DCD) lungs. PMID:25132972

  13. Ex vivo lung perfusion

    PubMed Central

    Machuca, Tiago N.

    2014-01-01

    Lung transplantation (LTx) is an established treatment option for eligible patients with end-stage lung disease. Nevertheless, the imbalance between suitable donor lungs available and the increasing number of patients considered for LTx reflects in considerable waitlist mortality. Among potential alternatives to address this issue, ex vivo lung perfusion (EVLP) has emerged as a modern preservation technique that allows for more accurate lung assessment and also improvement of lung function. Its application in high-risk donor lungs has been successful and resulted in safe expansion of the donor pool. This article will: (I) review the technical details of EVLP; (II) the rationale behind the method; (III) report the worldwide clinical experience with the EVLP, including the Toronto technique and others; (IV) finally, discuss the growing literature on EVLP application for donation after cardiac death (DCD) lungs. PMID:25132972

  14. A model of ventilation of the healthy human lung.

    PubMed

    Steimle, K L; Mogensen, M L; Karbing, D S; Bernardino de la Serna, J; Andreassen, S

    2011-02-01

    This paper presents a model of the lung mechanics which simulates the pulmonary alveolar ventilation. The model includes aspects of: the alveolar geometry; pressure due to the chest wall; pressure due to surface tension determined by surfactant activity; pressure due to lung tissue elasticity; and pressure due to the hydrostatic effects of the lung tissue and blood. The cross-sectional area of the lungs in the supine position derived from computed tomography is used to construct a horizontally layered model, which simulates heterogeneous ventilation distribution from the non-dependent to the dependent layers of the lungs. The model is in agreement with experimentally measured hysteresis of the pressure-volume curve of the lungs, static lung compliance, changes in lung depth during breathing and density distributions at total lung capacity (TLC) and residual volume (RV). In the dependent layers of the lungs, alveolar collapse may occur at RV, depending on the assumptions concerning lung tissue elasticity at very low alveolar volumes. The model simulations showed that ventilation increased with depth in the lungs, although not as pronounced as observed experimentally. The model simulates alveolar ventilation including all of the mentioned components of the respiratory system and to be validated against all the above mentioned experimental data. PMID:20655612

  15. Lung Cancer in Never Smokers

    PubMed Central

    Yang, Ping

    2012-01-01

    Lung cancer in never smokers (LCINS) has lately been recognized as a unique disease based on rapidly gained knowledge from genomic changes to treatment responses. The focus of this article is on current knowledge and challenges with regard to LCINS expanded from recent reviews highlighting five areas: (1) distribution of LCINS by temporal trends, geographic regions, and populations; (2) three well-recognized environmental risk factors; (3) other plausible environmental risk factors; (4) prior chronic lung diseases and infectious diseases as risk factors; and (5) lifestyles as risk or protective factors. This article will also bring attention to recently published literature in two pioneering areas: (1) histological characteristics, clinical features with emerging new effective therapies, and social and psychological stigma; and (2) searching for susceptibility genes using integrated genomic approaches. PMID:21500120

  16. Occupational lung cancer.

    PubMed

    Cone, J E

    1987-01-01

    The author addresses the attribution of lung cancer to cigarette smoking and the problems of confounding synergistic effects of occupational and other carcinogenic risk factors, as well as the divergent trends of declining smoking rates and increasing rates of lung cancer. He also reviews the existing literature to document associations between lung cancer and occupational exposures. Finally, interventions for prevention of occupational lung cancer are discussed. PMID:3303381

  17. Occupational lung cancer

    SciTech Connect

    Cone, J.E.

    1987-04-01

    The author addresses the attribution of lung cancer to cigarette smoking and the problems of confounding synergistic effects of occupational and other carcinogenic risk factors, as well as the divergent trends of declining smoking rates and increasing rates of lung cancer. He also reviews the existing literature to document associations between lung cancer and occupational exposures. Finally, interventions for prevention of occupational lung cancer are discussed.

  18. Studies of Lung Micromechanics via Hyperpolarized Helium-3 Diffusion NMR

    NASA Astrophysics Data System (ADS)

    Hajari, Adam James

    While high quality MR Images of lungs are difficult to obtain with conventional proton MRI due to the organ's low tissue density, the advent of techniques in noble gas polarization have enabled MR investigations of the lung's more abundant air space rather than its tissue. In addition to high-resolution images of lung ventilation, lung morphometry via gas diffusion NMR provides information about the size and shape of the microscopic airways that account for over 95% of the lung's airspace. Consequently, gas diffusion NMR provides an important new tool for investigating changes in lung microstructure during macroscopic changes in lung volume. Despite decades of research into the mechanisms of lung inflation and deflation, there is little consensus about whether macroscopic changes in lung volume occur due to changes in the size and/or shape of alveoli and alveolar ducts or by alveolar recruitment and derecruitment. In this dissertation lung morphometry is performed via 3He diffusion MRI in order to measure the average alveolar depth and alveolar duct radius at multiple levels of both inspiration and expiration in in vivo human subjects and in explanted human and canine lungs. Average alveolar volume, surface area, and the total number of alveoli at each lung volume are calculated from the 3He morphometric parameters. The results suggest that human lungs inflate/deflate primarily by recruitment/derecruitment of alveoli, and that individual alveolar ducts in both human and canine lungs increase in volume non-isotropically by accordion-like extension. The results further suggest that this change in alveolar duct volume is the primary mechanism of lung volume change in canine lungs but is secondary to alveolar recruitment/derecruitment in humans.

  19. Lung cancer prevention.

    PubMed

    Slatore, Christopher; Sockrider, Marianna

    2014-11-15

    Lung cancer is a common form of cancer.There are things you can do to lower your risk of lung cancer. Stop smoking tobacco. Ask your health care provider for help in quitting, including use of medicines to help with nicotine dependence. discuss with your healthcare provider,what you are taking or doing to decrease your risk for lung cancer PMID:25398122

  20. Lung tissue engineering.

    PubMed

    Hoganson, David M; Bassett, Erik K; Vacanti, Joseph P

    2014-01-01

    Lung tissue engineering is an emerging field focused on the development of lung replacement devices and tissue to treat patients with end stage lung disease. Microfluidic based lung assist devices have been developed that have biomimetically designed vascular networks that achieve physiologic blood flow. Gas exchange in these devices occurs across a thin respiratory membrane. Designed for intrathoracic implantation as a bridge to transplant or destination therapy, these lung assist devices will allow ambulation and hospital discharge for patients with end stage lung disease. Decellularized lungs subsequently recellularized with epithelial and endothelial cells have been implanted in small animal models with demonstration of initial gas exchange. Further development of these tissues and scaling to large animal models will validate this approach and may be an organ source for lung transplantation. Initial clinical success has been achieved with decellularized tracheal implants using autologous stem cells. Development of microfluidic lung models using similar architecture to the lung assist device technology allows study of lung biology and diseases with manipulation of lung cells and respiratory membrane strain. PMID:24896347

  1. Treatment of wastewater from an oil refinery sour water stripping unit using an aerated submerged biological filter

    SciTech Connect

    Ramaswamy, J.; Veenstra, J.N.

    1995-12-31

    The purpose of this research was to determine the kinetic constants for an Aerated Submerged Biological Filter (ASBF) used to reduce the toxicity of a petroleum refinery Process wastewater. The system was run at three different organic loadings and data were collected at steady state conditions for each loading. This data along with data obtained for three other loading conditions done a previous study (1) were used to determine the biokinetics constants which are required for the design of a full scale system. To measure the acute toxicity reduction, a 48- hour static bioassay was done on the ASBF unit influent and effluent. An attempt was also made to identify a significant fraction contributing to the toxicity by running the samples through a clinoptilolite column and then running a bioassay on the treated samples. At lower loading conditions (14.0 g COD/m{sup 2}/day), the ASBF gave maximum reduction of monitored parameters except ammonia. At the highest loading condition (24.0 COD/m{sup 2}/day), the reductions were smaller because the unit seemed to be operating near maximum organic loading capacity. Bioassays showed the LC{sub 50} generally increased after ASBF treatment, indicating toxicity reduction. The bioassays done on the samples treated by clinoptilolite showed further increase in the LC{sub 50} for the ASBF unit effluent indicating that ammonia may be a toxic fraction in the effluent. The kinetic constants were analyzed using the models proposed by Eckenfelder (2) and Korengay and Andrews (3). The proportionality constant for the former was equal to 0.00458 m{sup 3}/m{sup 2}/day. The area capacity constant for the latter was 22.8 g/m{sup 2}/day and the saturation constant 88.8 mg/{ell}. A model proposed by Kincannon and Stover (4) was also used to predict the kinetic constants. From this model the maximum specific substrate removal rate was determined to be 33.3 g/m{sup 2}/day and the proportionality constant was equal to 23.7 g/m{sup 2}/day.

  2. Nitrogen removal from on-site treated anaerobic effluents using intermittently aerated moving bed biofilm reactors at low temperature.

    PubMed

    Luostarinen, Sari; Luste, Sami; Valentín, Lara; Rintala, Jukka

    2006-05-01

    On-site post-treatment of anaerobically pre-treated dairy parlour wastewater (DPWWe; 10 degrees C) and mixture of kitchen waste and black water (BWKWe; 20 degrees C) was studied in moving bed biofilm reactors (MBBR). The focus was on removal of nitrogen and of residual chemical oxygen demand (COD). Moreover, the effect of intermittent aeration and continuous vs. sequencing batch operation was studied. All MBBRs removed 50-60% of nitrogen and 40-70% of total COD (CODt). Complete nitrification was achieved, but denitrification was restricted by lack of carbon. Nitrogen removal was achieved in a single reactor by applying intermittent aeration. Continuous and sequencing batch operation provided similar nitrogen and COD removal, wherefore simpler continuous feeding may be preferred for on-site applications. Combination of pre-treating upflow anaerobic sludge blanket (UASB) -septic tank and MBBR removed over 92% of CODt, 99% of biological oxygen demand (BOD7), and 65-70% of nitrogen. PMID:16647521

  3. Relative quantitative PCR to assess bacterial community dynamics during biodegradation of diesel and biodiesel fuels under various aeration conditions.

    PubMed

    Cyplik, Paweł; Schmidt, Marcin; Szulc, Alicja; Marecik, Roman; Lisiecki, Piotr; Heipieper, Hermann J; Owsianiak, Mikołaj; Vainshtein, Mikhail; Chrzanowski, Łukasz

    2011-03-01

    The degradation of diesel fuel, B20 blend and biodiesel in liquid cultures by a seven-member bacterial consortium was compared under conditions with full aeration or with limited aeration with nitrate added as main electron acceptor. Community dynamics was assessed employing real-time PCR and the ddCt method for relative quantification. Biodegradation rates increased with increasing biodiesel content, but were significantly reduced under conditions with nitrate. Despite large variations in biodegradation rates, magnitude changes in population numbers were typically observed only from zero to one order, regardless the type of fuel and electron acceptor. Only Comamonadaceae and Variovorax sp. distinctly preferred aerobic conditions, and during aerobic growth showed suppression as fuel contained more biodiesel. Thus, the consortium is relatively stable and most of the degraders can shift their metabolism from hydrocarbons to biodiesel. The stability of the consortium is of interest in the context of biodiesel-mediated biodegradation of petroleum hydrocarbons. PMID:21239170

  4. Soil aeration to achieve co-metabolic biodegradation of chlorinated solvents in the presence of inducer compounds

    SciTech Connect

    Eisenbeis, J.J.; Bourquin, A.W.

    1995-12-31

    A chemical distribution facility in Denver has been found to have soil and ground water contaminated with a wide variety of organic compounds, primarily toluene and chlorinated solvents, and their breakdown products. Since toluene and chlorobenzenes (both present at the site) have been shown to be inducers for an aerobic enzyme pathway that can degrade trichloroethene (TCE), 1,2-dichloroethene (DCE) and vinyl chloride, field and laboratory studies are being conducted to determine if cometabolic aerobic biodegradation of these and other compounds is occurring in soils that have been aerated with soil vapor extraction (SVE). Studies summarized in this paper include in situ respiration tests to estimate overall biodegradation rate in aerated soils within the influence of a SVE system, sampling to determine if in situ biodegradation of chlorinated volatile organic compounds in ground water has occurred, and a laboratory column study simulating bioventing of unremediated soils.

  5. Removal of aqueous-phase petroleum products in ground water by aeration. Final report, Aug-Dec 88

    SciTech Connect

    Wickramanayake, G.B.; Arthur, M.F.; Pollack, A.J.; Krishnan, S.

    1992-06-01

    This study evaluated the effectiveness of conventional air stripping for removal of jet fuels (JP-5 and AVGAS) from groundwater, using samples collected near the Patuxent River Naval Air Station fuel farm in NM. Using an air flow rate of 0.3 L/min, fuel contaminants (a mixture of JP-3 and AVGAS) were removed in excess of 97% within 30 minutes. At the same flow rate, 96% of a less volatile fuel contaminant (primarily JP-3) was removed in 30 minutes. These results indicate that even low volatility jet fuel can be removed from groundwater to low levels (<2 mg/L) by air stripping. Iron precipitation during aeration of groundwater could plug packed-bed air strippers unless pre-aeration and iron precipitate removal was implemented before packed-bed air stripping.

  6. [Detection of anaerobic processes and microorganisms in immobilized activated sludge of a wastewater treatment plant with intense aeration].

    PubMed

    Litti, Iu V; Nekrasova, V K; Kulikov, N I; Siman'kova, M V; Nozhevnikova, A N

    2013-01-01

    Attached activated sludge from the Krasnaya Polyana (Sochi) wastewater treatment plant was studied after the reconstruction by increased aeration and water recycle, as well as by the installation of a bristle carrier for activated sludge immobilization. The activated sludge biofilms developing under conditions of intense aeration were shown to contain both aerobic and anaerobic microorganisms. Activity of a strictly anaerobic methanogenic community was revealed, which degraded organic compounds to methane, further oxidized by aerobic methanotrophs. Volatile fatty acids, the intermediates of anaerobic degradation of complex organic compounds, were used by both aerobic and anaerobic microorganisms. Anaerobic oxidation of ammonium with nitrite (anammox) and the presence of obligate anammox bacteria were revealed in attached activated sludge biofilms. Simultaneous aerobic and anaerobic degradation of organic contaminants by attached activated sludge provides for high rates of water treatment, stability of the activated sludge under variable environmental conditions, and decreased excess sludge formation. PMID:25509405

  7. Pulping wastewater treatment: Aeration processes and equipment. (Latest citations from the Paper and Board, Printing, and Packaging Industries Research Associations database). Published Search

    SciTech Connect

    Not Available

    1993-06-01

    The bibliography contains citations concerning plant operations and methods, pilot plant and laboratory tests and results of pulping mill wastewater treatment by aeration. Composition of effluent components including condensates, bleaching effluents, and spent liquor are discussed. Foreign and domestic plant efficiency, performance reports, and cost data are considered. Aerator design, lagoon treatment system upgrading considerations, and environmental aspects are included. (Contains a minimum of 88 citations and includes a subject term index and title list.)

  8. Lung Cancer Staging and Prognosis.

    PubMed

    Woodard, Gavitt A; Jones, Kirk D; Jablons, David M

    2016-01-01

    The seventh edition of the non-small cell lung cancer (NSCLC) TNM staging system was developed by the International Association for the Staging of Lung Cancer (IASLC) Lung Cancer Staging Project by a coordinated international effort to develop data-derived TNM classifications with significant survival differences. Based on these TNM groupings, current 5-year survival estimates in NSLCC range from 73 % in stage IA disease to 13 % in stage IV disease. TNM stage remains the most important prognostic factor in predicting recurrence rates and survival times, followed by tumor histologic grade, and patient sex, age, and performance status. Molecular prognostication in lung cancer is an exploding area of research where interest has moved beyond TNM stage and into individualized genetic tumor analysis with immunohistochemistry, microarray, and mutation profiles. However, despite intense research efforts and countless publications, no molecular prognostic marker has been adopted into clinical use since most fail in subsequent cross-validation with few exceptions. The recent interest in immunotherapy for NSCLC has identified new biomarkers with early evidence that suggests that PD-L1 is a predictive marker of a good response to new immunotherapy drugs but a poor prognostic indicator of overall survival. Future prognostication of outcomes in NSCLC will likely be based on a combination of TNM stage and molecular tumor profiling and yield more precise, individualized survival estimates and treatment algorithms. PMID:27535389

  9. Method of aeration disinfecting and drying grain in bulk and pretreating seeds and a transverse blow silo grain dryer therefor

    DOEpatents

    Danchenko, Vitaliy G.; Noyes, Ronald T.; Potapovych, Larysa P.

    2012-02-28

    Aeration drying and disinfecting grain crops in bulk and pretreating seeds includes passing through a bulk of grain crops and seeds disinfecting and drying agents including an ozone and air mixture and surrounding air, subdividing the disinfecting and drying agents into a plurality of streams spaced from one another in a vertical direction, and passing the streams at different heights through levels located at corresponding heights of the bulk of grain crops and seeds transversely in a substantially horizontal direction.

  10. CFTR and lung homeostasis

    PubMed Central

    Matalon, Sadis

    2014-01-01

    CFTR is a cAMP-activated chloride and bicarbonate channel that is critical for lung homeostasis. Decreases in CFTR expression have dire consequences in cystic fibrosis (CF) and have been suggested to be a component of the lung pathology in chronic obstructive pulmonary disease. Decreases or loss of channel function often lead to mucus stasis, chronic bacterial infections, and the accompanying chronic inflammatory responses that promote progressive lung destruction, and, eventually in CF, lung failure. Here we discuss CFTR's functional role airway surface liquid hydration and pH, in regulation of other channels such as the epithelial sodium channel, and in regulating inflammatory responses in the lung. PMID:25381027

  11. The lung in space

    NASA Technical Reports Server (NTRS)

    Prisk, G. Kim

    2005-01-01

    The lung is exquisitely sensitive to gravity, which induces gradients in ventilation, blood flow, and gas exchange. Studies of lungs in microgravity provide a means of elucidating the effects of gravity. They suggest a mechanism by which gravity serves to match ventilation to perfusion, making for a more efficient lung than anticipated. Despite predictions, lungs do not become edematous, and there is no disruption to, gas exchange in microgravity. Sleep disturbances in microgravity are not a result of respiratory-related events; obstructive sleep apnea is caused principally by the gravitational effects on the upper airways. In microgravity, lungs may be at greater risk to the effects of inhaled aerosols.

  12. Xenogeneic lung transplantation models

    PubMed Central

    Burdorf, Lars; Azimzadeh, Agnes M.; Pierson, Richard N.

    2014-01-01

    Summary Study of lung xenografts has proven useful to understand the remaining barriers to successful transplantation of other organ xenografts. In this chapter, the history and current status of lung xenotransplantation will be briefly reviewed and two different experimental models, the ex vivo porcine-to-human lung perfusion and the in vivo xenogeneic lung transplantation, will be presented. We will focus on the technical details of these lung xenograft models in sufficient detail, list the needed materials and mention analysis techniques to allow others to adopt them with minimal learning curve. PMID:22565996

  13. Lung cancer in women.

    PubMed

    Coscio, Angela M; Garst, Jennifer

    2006-07-01

    Lung cancer is the most common cancer in both men and women; however, there are some clear gender-based differences. As the incidence of lung cancer is declining in men, the incidence of lung cancer is increasing in women. Women are more likely than men to have adenocarcinoma, a histologic subtype that correlates with worsened prognosis, but women have improved survival compared with men. Genetic predisposition and the presence of estrogen receptors in lung cancer cells may predispose women to developing lung cancer. Further studies are needed to understand the mechanism and significance of these findings. PMID:17254523

  14. Perioperative lung injury.

    PubMed

    Slinger, Peter

    2008-03-01

    Patients are at risk for several types of lung injury in the perioperative period. These injuries include atelectasis, pneumonia, pneumothorax, bronchopleural fistula, acute lung injury and acute respiratory distress syndrome. Anesthetic management can cause, exacerbate or ameliorate most of these injuries. Clinical research trends show that traditional protocols for perioperative mechanical ventilation, using large tidal volumes without positive end-expiratory pressure (PEEP) can cause a sub-clinical lung injury and this injury becomes clinically important when any additional lung injury is added. Lung-protective ventilation strategies using more physiologic tidal volumes and appropriate levels of PEEP can decrease the extent of this injury. PMID:18494396

  15. Positive effect of reduced aeration rate on growth and stereospecificity of DL-malic acid consumption by Azospirillum brasilense: improving the shelf life of a liquid inoculant formulation.

    PubMed

    Carrasco-Espinosa, Karen; García-Cabrera, Ramsés I; Bedoya-López, Andrea; Trujillo-Roldán, Mauricio A; Valdez-Cruz, Norma A

    2015-02-10

    Azospirillum brasilense has significance as a growth promoter in plants of commercial interest. Two industrial native strains (Start and Calf), used as a part of an inoculant formulation in Mexico during the last 15 years, were incubated in laboratory-scale pneumatic bioreactors at different aeration rates. In both strains, the positive effect of decreased aeration was observed. At the lowest (0.1 vvm, air volume/liquid volume×minute), the highest biomass were obtained for Calf (7.8 × 10(10)CFU/ml), and Start (2.9 × 10(9)CFU/ml). These were higher in one magnitude order compared to cultures carried out at 0.5 vvm, and two compared to those at 1.0 vvm. At lower aeration, both stereoisomeric forms of malic acid were consumed, but at higher aeration, just L-malate was consumed. A reduction in aeration allows an increase of the shelf life and the microorganism saved higher concentrations of polyhydroxybutyrate. The selected fermentation conditions are closely related to those prevalent in large-scale bioreactors and offer the possibility of achieving high biomass titles with high shelf life at a reduced costs, due to the complete use of a carbon source at low aeration of a low cost raw material as DL-malic acid mixture in comparison with the L-malic acid stereoisomer. PMID:25556026

  16. Effect of Post-Infiltration Soil Aeration at Different Growth Stages on Growth and Fruit Quality of Drip-Irrigated Potted Tomato Plants (Solanum lycopersicum)

    PubMed Central

    Li, Yuan; Jia, Zongxia; Niu, Wenquan; Wang, Jingwei; Zhang, Mingzhi

    2015-01-01

    Soil hydraulic principles suggest that post-infiltration hypoxic conditions would be induced in the plant root-zone for drip-irrigated tomato production in small pots filled with natural soil. No previous study specifically examined the response of tomato plants (Solanum lycopersicum) at different growth stages to low soil aeration under these conditions. A 2 × 6 factorial experiment was conducted to quantify effects of no post-infiltration soil aeration versus aeration during 5 different periods (namely 27–33, 34–57, 58–85, 86–99, and 27–99 days after sowing), on growth and fruit quality of potted single tomato plants that were sub-surface trickle-irrigated every 2 days at 2 levels. Soil was aerated by injecting 2.5 liters of air into each pot through the drip tubing immediately after irrigation. Results showed that post-infiltration aeration, especially during the fruit setting (34–57 DAS) and enlargement (58–85 DAS) growth stages, can positively influence the yield, root dry weight and activity, and the nutritional (soluble solids and vitamin C content), taste (titratable acidity), and market quality (shape and firmness) of the tomato fruits. Interactions between irrigation level and post-infiltration aeration on some of these fruit quality parameters indicated a need for further study on the dynamic interplay of air and water in the root zone of the plants under the conditions of this experiment. PMID:26630675

  17. Effect of Post-Infiltration Soil Aeration at Different Growth Stages on Growth and Fruit Quality of Drip-Irrigated Potted Tomato Plants (Solanum lycopersicum).

    PubMed

    Li, Yuan; Jia, Zongxia; Niu, Wenquan; Wang, Jingwei; Zhang, Mingzhi

    2015-01-01

    Soil hydraulic principles suggest that post-infiltration hypoxic conditions would be induced in the plant root-zone for drip-irrigated tomato production in small pots filled with natural soil. No previous study specifically examined the response of tomato plants (Solanum lycopersicum) at different growth stages to low soil aeration under these conditions. A 2 × 6 factorial experiment was conducted to quantify effects of no post-infiltration soil aeration versus aeration during 5 different periods (namely 27-33, 34-57, 58-85, 86-99, and 27-99 days after sowing), on growth and fruit quality of potted single tomato plants that were sub-surface trickle-irrigated every 2 days at 2 levels. Soil was aerated by injecting 2.5 liters of air into each pot through the drip tubing immediately after irrigation. Results showed that post-infiltration aeration, especially during the fruit setting (34-57 DAS) and enlargement (58-85 DAS) growth stages, can positively influence the yield, root dry weight and activity, and the nutritional (soluble solids and vitamin C content), taste (titratable acidity), and market quality (shape and firmness) of the tomato fruits. Interactions between irrigation level and post-infiltration aeration on some of these fruit quality parameters indicated a need for further study on the dynamic interplay of air and water in the root zone of the plants under the conditions of this experiment. PMID:26630675

  18. Targeted modification of organic components of municipal solid waste by short-term pre-aeration and its enhancement on anaerobic degradation in simulated landfill bioreactors.

    PubMed

    Ni, Zhe; Liu, Jianguo; Girotto, Francesca; Cossu, Raffaello; Qi, Guangxia

    2016-09-01

    Pre-aeration is effective on regulating subsequent anaerobic degradation of municipal solid waste (MSW) with high organic fractions during landfilling. The strength of pre-aeration should be optimized to intentionally remove some easily biodegradable fractions while conserve bio-methane potential as much as possible. This study investigates the evolution of organic components in MSW during 2-14days pre-aeration process and its impacts on subsequent anaerobic degradation in simulated landfill bioreactors. Results showed that a 6-day pre-aeration enabled to develop a thermophilic stage, which significantly accelerated biodegradation of organics except lignocelluloses, with removal rates of 42.8%, 76.7% and 25.1% for proteins, carbohydrates and lipids, respectively. Particularly, ammonia from accelerated ammonification in the thermophilic stage neutralized VFAs generated from anaerobic landfilling. As a result, the MSW with 6-day pre-aeration obtained the highest methane yield 123.4NL/kg dry matter. Therefore, it is recommended to interrupt pre-aeration before its cooling stage to switch to anaerobic landfilling. PMID:27243602

  19. Comparative study on the reactivity of Fe/Cu bimetallic particles and zero valent iron (ZVI) under different conditions of N2, air or without aeration.

    PubMed

    Xiong, Zhaokun; Lai, Bo; Yang, Ping; Zhou, Yuexi; Wang, Juling; Fang, Shuping

    2015-10-30

    In order to further compare the degradation capacity of Fe(0) and Fe/Cu bimetallic system under different aeration conditions, the mineralization of PNP under different aeration conditions has been investigated thoroughly. The results show that the removal of PNP by Fe(0) or Fe/Cu system followed the pseudo-first-order reaction kinetics. Under the optimal conditions, the COD removal efficiencies obtained through Fe(0) or Fe/Cu system under different aeration conditions followed the trend that Fe/Cu (air)>Fe/Cu (N2: 0-30 min, air: 30-120 min)>control-Fe (air)>Fe/Cu (without aeration)>Fe/Cu (N2)>control-Fe (N2). It revealed that dissolved oxygen (DO) could improve the mineralization of PNP, and Cu could enhance the reactivity of Fe(0). In addition, the degradation of PNP was further analyzed by using UV-vis, FTIR and GC/MS, and the results suggest that Fe/Cu bimetallic system with air aeration could completely break the benzene ring and NO2 structure of PNP and could generate the nontoxic and biodegradable intermediate products. Meanwhile, most of these intermediate products were further mineralized into CO2 and H2O, which brought about a high COD removal efficiency (83.8%). Therefore, Fe/Cu bimetallic system with air aeration would be a promising process for toxic refractory industry wastewater. PMID:25978189

  20. Control of Grifola frondosa Morphology by Agitation and Aeration for Improving Mycelia and Exo-Polymer Production.

    PubMed

    Cui, Feng-Jie; Chen, Xiao-Xiao; Liu, Wei-Min; Sun, Wen-Jing; Huo, Shuhao; Yang, Yan

    2016-06-01

    The present study describes the improved mycelia and exo-polymer production under control of Grifola frondosa morphology by changing the aeration rate and agitation intensity in a 25-L stirred fermentor. The aeration rate of 1.0 vvm yielded a highest mycelia biomass of 24.754 g/L with the lowest pellet percentage of 20.5 %. The maximum exo-polymer (2.324 g/L) was achieved at 0.75 vvm with mycelia polysaccharide production (0.321 g/g), whereas clumps and filaments dominated the ratios of 45.6 and 33.9 %, respectively. The change of aeration rate and agitation intensity had slight influence on the monosaccharide compositions in exo-polymers and significantly affected glucose and mannose contents in the mycelia polysaccharides. These findings will provide a clue for exploring the relationship between fermentation parameters, morphologies, and polysaccharide synthesis pathway of G. frondosa. PMID:26861733