Science.gov

Sample records for aerobic carbon monoxide

  1. Carbon monoxide. Toxic gas and fuel for anaerobes and aerobes: carbon monoxide dehydrogenases.

    PubMed

    Jeoung, Jae-Hun; Fesseler, Jochen; Goetzl, Sebastian; Dobbek, Holger

    2014-01-01

    Carbon monoxide (CO) pollutes the atmosphere and is toxic for respiring organisms including man. But CO is also an energy and carbon source for phylogenetically diverse microbes living under aerobic and anaerobic conditions. Use of CO as metabolic fuel for microbes relies on enzymes like carbon monoxide dehydrogenase (CODH) and acetyl-CoA synthase (ACS), which catalyze conversions resembling processes that eventually initiated the dawn of life.CODHs catalyze the (reversible) oxidation of CO with water to CO2 and come in two different flavors with unprecedented active site architectures. Aerobic bacteria employ a Cu- and Mo-containing CODH in which Cu activates CO and Mo activates water and takes up the two electrons generated in the reaction. Anaerobic bacteria and archaea use a Ni- and Fe-containing CODH, where Ni activates CO and Fe provides the nucleophilic water. Ni- and Fe-containing CODHs are frequently associated with ACS, where the CODH component reduces CO2 to CO and ACS condenses CO with a methyl group and CoA to acetyl-CoA.Our current state of knowledge on how the three enzymes catalyze these reactions will be summarized and the different strategies of CODHs to achieve the same task within different active site architectures compared.

  2. Maximal aerobic capacity at several ambient concentrations of carbon monoxide at several altitudes. Research report, April 1984-January 1988

    SciTech Connect

    Horvath, S.M.; Agnew, J.W.; Wagner, J.A.; Bedi, J.F.

    1988-12-01

    To assess the combined effects of altitude and acute carbon monoxide exposure, 11 male and 12 female subjects, all nonsmokers in good health, were given incremental maximal aerobic-capacity tests. Each subject, after attaining the required altitude and ambient carbon monoxide level, performed the maximal aerobic capacity test. Blood samples were drawn at several points in the aerobic capacity test protocol, and analyzed for hemoglobin, hematocrit, plasma proteins, lactates, and carboxyhemoglobin. Carbon-monoxide-carboxyhemoglobin uptake rates were derived from the submaximal workloads. Despite increases in carboxyhemoglobin, no additional significant decreases in maximal aerobic capacity were observed. Immediately prior to and at maximal workloads, carbon monoxide shifted into extravascular spaces and returned to the vascular space within five minutes after exercise stopped.

  3. Carbon Monoxide (CO)

    MedlinePlus

    ... United States Environmental Protection Agency Search Search Indoor Air Quality (IAQ) Share Facebook Twitter Google+ Pinterest Contact Us Carbon Monoxide's Impact on Indoor Air Quality On this page: Overview Sources of Carbon Monoxide ...

  4. Instrumental carbon monoxide dosimetry.

    PubMed

    Stetter, J R; Rutt, D R

    1980-10-01

    Modern technology for the ambient monitoring of carbon monoxide has been developed to produce a portable electrochemical instrument capable of the personal exposure to carbon monoxide. The performance characteristics of this device have been studied so that the unambiguous interpretation of field data could be performed. A study of the carbon monoxide exposure in a light manufacturing facility illustrate that effective dosimetry can be performed with expectations of accuracy typically better than +/- 15%, and that voluntary carbon monoxide exposures such as smoking were a significant contribution to the individual's exposure. Significant definition of the carbon monoxide exposure profile can be achieved with an instrument approach to the collection of the dosimetric data.

  5. Accidental carbon monoxide poisoning.

    PubMed

    Zeller, W P; Miele, A; Suarez, C; Hannigan, J; Hurley, R M

    1984-12-01

    In this case report of an accidental automobile carbon monoxide poisoning, we identify the following risk factors: freezing temperature, young passenger age, location in the rear of the auto, smaller patient mass, and auto disrepair. The pathogenesis of carbon monoxide poisoning is reviewed. Emergency treatment and suggested criteria for hyperbaric oxygen use in pediatric patients are discussed.

  6. Estimating carbon monoxide exposure

    NASA Technical Reports Server (NTRS)

    Edgerley, R. H.

    1971-01-01

    Method predicts effects of carbon monoxide on astronauts confined in spacecraft cabin atmospheres. Information on need for low toxicity level also applies to confined spaces. Benefits are applicable to industry and public health.

  7. Carbon monoxide poisoning

    MedlinePlus

    ... any major gas-burning appliances (such as a furnace or water heater). Many carbon monoxide poisonings occur in the winter months when furnaces, gas fireplaces, and portable heaters are being used ...

  8. Carbon monoxide intoxication

    SciTech Connect

    Kales, S.N. )

    1993-11-01

    Carbon monoxide poisoning usually results from inhalation of exhaust fumes from motor vehicles, smoke from fires or fumes from faulty heating systems. Carbon monoxide has a high affinity for hemoglobin, with which it forms carboxyhemoglobin. The resulting decrease in both oxygen-carrying capacity and oxygen release can lead to end-organ hypoxia. The clinical presentation is nonspecific. Headache, dizziness, fatigue and nausea are common in mild to moderate carbon monoxide poisoning. In more severe cases, tachycardia, tachypnea and central nervous system depression occur. When carbon monoxide intoxication is suspected, empiric treatment with 100 percent oxygen should be initiated immediately. The diagnosis is confirmed by documenting an elevated carboxyhemoglobin level. Hyperbaric oxygen therapy is recommended in patients with neurologic dysfunction, cardiac dysfunction or a history of unconsciousness. 26 refs.

  9. Carbon Monoxide (CO) Poisoning Prevention

    MedlinePlus

    ... What's this? Submit Button Past Emails CDC Features Carbon Monoxide (CO) Poisoning Prevention Language: English Español (Spanish) ... tornadoes), using alternative sources of power can cause carbon monoxide (CO) to build up in a home ...

  10. Transmissivity of carbon monoxide

    NASA Technical Reports Server (NTRS)

    Drayson, S. R.; Tallamraju, R.; Chaney, L. W.

    1973-01-01

    The line strengths and self- and nitrogen-broadened half widths for selected lines of the 4.6 micron fundamental band of carbon monoxide were determined. The band strength determined at stp. is higher than previously reported measurements. The half widths agree well with other measurements and calculations.

  11. Solid State Carbon Monoxide Sensor

    NASA Technical Reports Server (NTRS)

    Upchurch, Billy T. (Inventor); Wood, George M. (Inventor); Schryer, David R. (Inventor); Leighty, Bradley D. (Inventor); Oglesby, Donald M. (Inventor); Kielin, Erik J. (Inventor); Brown, Kenneth G. (Inventor); DAmbrosia, Christine M. (Inventor)

    1999-01-01

    A means for detecting carbon monoxide which utilizes an un-heated catalytic material to oxidize carbon monoxide at ambient temperatures. Because this reaction is exothermic, a thermistor in contact with the catalytic material is used as a sensing element to detect the heat evolved as carbon monoxide is oxidized to carbon dioxide at the catalyst surface, without any heaters or external heating elements for the ambient air or catalytic element material. Upon comparison to a reference thermistor, relative increases in the temperature of the sensing thermistor correspond positively with an increased concentration of carbon monoxide in the ambient medium and are thus used as an indicator of the presence of carbon monoxide.

  12. Analysis of carbon monoxide.

    PubMed

    Widdop, Brian

    2002-07-01

    The degree of exposure to carbon monoxide is most often assessed by measuring the blood carboxyhaemoglobin saturation. This measurement is relevant to investigations of acute accidental or deliberate poisoning and of chronic exposure in a domestic or work place environment. Simple spectrophotometric methods based on differential protein precipitation or dithionite reduction are prone to interference from other haemoglobin pigments and are imprecise for low-level estimations. Automated spectrophotometric devices (CO-oximeters) that estimate simultaneously total haemoglobin, percentage oxyhaemoglobin and percentage carboxyhaemoglobin have acceptable accuracy for carboxyhaemoglobin saturation levels of > 5% and are recommended for most clinical purposes. For the investigation of low-level exposure and the detection of increased haemolysis in neonates, more sensitive methods involving the release of carbon monoxide and its measurement by gas chromatography are required. Gas chromatographic methods are also appropriate when examining post-mortem blood samples where putrefaction or heat stress has resulted in a significant change in haemoglobin composition.

  13. Carbon Monoxide Targeting Mitochondria

    PubMed Central

    Queiroga, Cláudia S. F.; Almeida, Ana S.; Vieira, Helena L. A.

    2012-01-01

    Mitochondria present two key roles on cellular functioning: (i) cell metabolism, being the main cellular source of energy and (ii) modulation of cell death, by mitochondrial membrane permeabilization. Carbon monoxide (CO) is an endogenously produced gaseoustransmitter, which presents several biological functions and is involved in maintaining cell homeostasis and cytoprotection. Herein, mitochondrion is approached as the main cellular target of carbon monoxide (CO). In this paper, two main perspectives concerning CO modulation of mitochondrial functioning are evaluated. First, the role of CO on cellular metabolism, in particular oxidative phosphorylation, is discussed, namely, on: cytochrome c oxidase activity, mitochondrial respiration, oxygen consumption, mitochondrial biogenesis, and general cellular energetic status. Second, the mitochondrial pathways involved in cell death inhibition by CO are assessed, in particular the control of mitochondrial membrane permeabilization. PMID:22536507

  14. Medical helicopters: carbon monoxide risk?

    PubMed

    Poulton, T J

    1987-02-01

    Carbon monoxide exposure of medical personnel working beneath the turning rotor of a medical helicopter appeared to cause mild clinical illness. We measured the carbon monoxide levels found in various locations beneath the rotor of a jet helicopter under two different conditions. Carbon monoxide levels ranged from 8-76 ppm depending on location of sampling and speed of operation of the engine. This level of carbon monoxide is potentially a problem, as is the inhalation of jet fuel vapor, when working beneath the rotors of an operating helicopter.

  15. Carbon monoxide poisoning.

    PubMed

    Guzman, Jorge A

    2012-10-01

    Carbon monoxide (CO) poisoning is the leading cause of death as a result of unintentional poisoning in the United States. CO toxicity is the result of a combination of tissue hypoxia-ischemia secondary to carboxyhemoglobin formation and direct CO-mediated damage at a cellular level. Presenting symptoms are mostly nonspecific and depend on the duration of exposure and levels of CO. Diagnosis is made by prompt measurement of carboxyhemoglobin levels. Treatment consists of the patient's removal from the source of exposure and the immediate administration of 100% supplemental oxygen in addition to aggressive supportive measures. The use of hyperbaric oxygen is controversial.

  16. [Acute carbon monoxide poisoning].

    PubMed

    Raphaël, Jean-Claude

    2008-04-30

    Carbon monoxide (CO) poisoning is still complicated by a high mortality and morbidity rate. Diagnosis can be obvious but is most of time difficult and sometimes remained unknown. It is usually based on clinical signs and must be confirmed by assessment of CO level in room air or in patient's expired breathing or blood and detection of a source. Mild neurological sequelae are very common. Normobaric oxygen is the first line treatment. Comatose and pregnant patients must undergo hyperbaric oxygen. All CO poisoning has to be declared to sanitary authority, which will in turn conduct a technical inspection to remove the source. The patient must be informed that he is at risk of new poisoning and of neurological complications. Progress in prevention and research in therapeutics are needed in order to reduce CO related morbidity.

  17. Carbon monoxide intoxication.

    PubMed

    Bleecker, Margit L

    2015-01-01

    Carbon monoxide (CO) is a colorless, odorless, nonirritant gas that accounts for numerous cases of CO poisoning every year from a variety of sources of incomplete combustion of hydrocarbons. These include poorly functioning heating systems, indoor propane-powered forklifts, indoor burning of charcoal burning briquettes, riding in the back of pick-up trucks, ice skating rinks using propane-powered resurfacing machines, and gasoline-powered generators that are not in correct locations. Once CO is inhaled it binds with hemoglobin to form carboxyhemoglobin (COHb) with an affinity 200 times greater than oxygen that leads to decreased oxygen-carrying capacity and decreased release of oxygen to tissues leading to tissue hypoxia. Ischemia occurs with CO poisoning when there is loss of consciousness that is accompanied by hypotension and ischemia in the arterial border zones of the brain. Besides binding to many heme-containing proteins, CO disrupts oxidative metabolism leading to the formation of free radicals. Once hypotension and unconsciousness occur with CO poisoning, lipid peroxidation and apoptosis follow. Because COHb has a short half-life, examination of other biomarkers of CO neurotoxicity that reflect inflammation or neuronal damage has not demonstrated consistent results. The initial symptoms with CO exposure when COHb is 15-30% are nonspecific, namely, headache, dizziness, nausea, fatigue, and impaired manual dexterity. However individuals with ischemic heart disease may experience chest pain and decreased exercise duration at COHb levels between 1% and 9%. COHb levels between 30% and 70% lead to loss of consciousness and eventually death. Following resolution of acute symptoms there may be a lucid interval of 2-40 days before the development of delayed neurologic sequelae (DNS), with diffuse demyelination in the brain accompanied by lethargy, behavior changes, forgetfulness, memory loss, and parkinsonian features. Seventy-five percent of patients with DNS

  18. Conversion of carbon-containing materials to carbon monoxide

    SciTech Connect

    Davis, G. D.; Hill, J. C.; Mcminn, T. D.; Rooks, C. W.

    1981-06-09

    Carbon-containing materials are gasified to produce high purity carbon monoxide in a three zone unified system (Oxidizer, reducer and gasifier) using a metal oxide as the oxygen and heat source for the gasification with carbon monoxide. Carbon monoxide contacts the metal oxide prior to the gasification to release the oxygen and convert the carbon monoxide to carbon dioxide as the gasification medium.

  19. 29 CFR 1917.24 - Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Carbon monoxide. 1917.24 Section 1917.24 Labor Regulations...) MARINE TERMINALS Marine Terminal Operations § 1917.24 Carbon monoxide. (a) Exposure limits. The carbon... employees shall be removed from the enclosed space if the carbon monoxide concentration exceeds a ceiling...

  20. 29 CFR 1917.24 - Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 7 2011-07-01 2011-07-01 false Carbon monoxide. 1917.24 Section 1917.24 Labor Regulations...) MARINE TERMINALS Marine Terminal Operations § 1917.24 Carbon monoxide. (a) Exposure limits. The carbon... employees shall be removed from the enclosed space if the carbon monoxide concentration exceeds a ceiling...

  1. 29 CFR 1917.24 - Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Carbon monoxide. 1917.24 Section 1917.24 Labor Regulations...) MARINE TERMINALS Marine Terminal Operations § 1917.24 Carbon monoxide. (a) Exposure limits. The carbon... employees shall be removed from the enclosed space if the carbon monoxide concentration exceeds a ceiling...

  2. 29 CFR 1917.24 - Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Carbon monoxide. 1917.24 Section 1917.24 Labor Regulations...) MARINE TERMINALS Marine Terminal Operations § 1917.24 Carbon monoxide. (a) Exposure limits. The carbon... employees shall be removed from the enclosed space if the carbon monoxide concentration exceeds a ceiling...

  3. 29 CFR 1917.24 - Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Carbon monoxide. 1917.24 Section 1917.24 Labor Regulations...) MARINE TERMINALS Marine Terminal Operations § 1917.24 Carbon monoxide. (a) Exposure limits. The carbon... employees shall be removed from the enclosed space if the carbon monoxide concentration exceeds a ceiling...

  4. (Carbon monoxide metabolism by photosynthetic bacteria)

    SciTech Connect

    Not Available

    1989-01-01

    Research continued on the metabolism of carbon monoxide by Rhodospirillum rubrum. This report discusses progress on the activity, induction, inhibition, and spectroscopic analysis of the enzyme Carbon Monoxide Dehydrogenase. (CBS)

  5. Carbon monoxide and lethal arrhythmias

    SciTech Connect

    Farber, J.P.; Schwartz, P.J.; Vanoli, E.; Stramba-Badiale, M.; De Ferrari, G.M. )

    1990-12-01

    The effect of acute exposure to carbon monoxide on ventricular arrhythmias was studied in a previously described chronically maintained animal model of sudden cardiac death. In 60 percent of dogs with a healed anterior myocardial infarction, the combination of mild exercise and acute myocardial ischemia induces ventricular fibrillation. The events in this model are highly reproducible, thus allowing study by internal control analysis. Dogs that develop ventricular fibrillation during the test of exercise and acute myocardial ischemia are considered at high risk for sudden death and are defined as 'susceptible'; dogs that survive the test without a fatal arrhythmia are considered at low risk for sudden death and are defined as 'resistant.' In the current study, the effects of carboxyhemoglobin levels ranging from 5 to 15 percent were tested in resistant and susceptible dogs. A trend toward higher heart rates was observed at all levels of carboxyhemoglobin, although significant differences were observed only with 15 percent carboxyhemoglobin. This trend was observed at rest and during exercise in both resistant and susceptible dogs. In resistant animals, in which acute myocardial ischemia is typically associated with bradycardia even under the control condition, this reflex response occurred earlier and was augmented after exposure to carbon monoxide. This effect may depend on the increased hypoxic challenge caused by carbon monoxide, and thus on an augmentation of the neural reflex activation or a sensitization of the sinus node to acetylcholine induced by hypoxia. In both resistant and susceptible dogs, carbon monoxide exposure induced a worsening of ventricular arrhythmias in a minority of cases. This worsening was not reproducible in subsequent trials. These data indicate that acute exposure to carbon monoxide is seldom arrhythmogenic in dogs that have survived myocardial infarction. (Abstract Truncated)

  6. Carbon Monoxide from Biomass Burning

    NASA Technical Reports Server (NTRS)

    2002-01-01

    This pair of images shows levels of carbon monoxide at the atmospheric pressure level of 700 millibars (roughly 12,000 feet in altitude) over the continent of South America, as observed by the Measurements Of Pollution In The Troposphere (MOPITT) sensor flying aboard NASA's Terra spacecraft. Data for producing the image on the left were acquired on March 3, 2000, and for the image on the right on September 7, 2000. Blue pixels show low values, yellows show intermediate values, and the red to pink and then white pixels are progressively higher values. In the lefthand image (March 3), notice the fairly low levels of carbon monoxide over the entire continent. The slightly higher equatorial values are the result of burning emissions in sub-Saharan Africa that are convected at the Intertropical Convergence Zone (ITCZ) and spread by the trade winds. Also, notice the effect of the elevated surface topography across the Andes Mountains running north to south along the western coastline. (In this region, white pixels show no data.) In the righthand image (September 7), a large carbon monoxide plume is seen over Brazil, produced primarily by biomass burning across Amazonia and lofted into the atmosphere by strong cloud convection. The generally higher carbon monoxide levels as compared to March are both the result of South American fire emissions and the transport of carbon monoxide across the Atlantic Ocean from widespread biomass burning over Southern Africa. These images were produced using MOPITT data, which are currently being validated. These data were assimilated into an atmospheric chemical transport model using wind vectors provided by the National Center for Environmental Prediction (NCEP). Although there is good confidence in the relative seasonal values and geographic variation measured by MOPITT, that team anticipates their level of confidence will improve further with ongoing intensive validation campaigns and comparisons with in situ and ground

  7. The Albuquerque carbon monoxide source apportionment study

    SciTech Connect

    Einfeld, W.

    1988-07-01

    At the request of the New Mexico Environmental Improvement Division, a study was carried out to examine, in detail, the relative contribution of various combustion sources to ambient carbon monoxide in Albuquerque during the winter season evening hours. The two-month field study (January--February 1985) included aerosol and gas monitoring at two sites in the Albuquerque area. Source contributions to ambient carbon monoxide were determined by regression techniques using tracer elements and by carbon isotope measurements on collected carbon monoxide. Results from isotopic carbon analysis of carbon monoxide show that, on average, mobile sources contributed 68 percent and wood burning sources 32 percent to ambient carbon monoxide levels during winter season evening hours. Good agreement was found between results from carbon isotope and linear regression techniques used to estimate average source strengths. The study results point to the significance of both mobile and residential wood burning sources as contributors to ambient carbon monoxide levels. 1 ref., 10 figs., 19 tabs.

  8. Carbon Monoxide Dehydrogenase Activity in Bradyrhizobium japonicum

    PubMed Central

    Lorite, María J.; Tachil, Jörg; Sanjuán, Juán; Meyer, Ortwin; Bedmar, Eulogio J.

    2000-01-01

    Bradyrhizobium japonicum strain 110spc4 was capable of chemolithoautotrophic growth with carbon monoxide (CO) as a sole energy and carbon source under aerobic conditions. The enzyme carbon monoxide dehydrogenase (CODH; EC 1.2.99.2) has been purified 21-fold, with a yield of 16% and a specific activity of 58 nmol of CO oxidized/min/mg of protein, by a procedure that involved differential ultracentrifugation, anion-exchange chromatography, hydrophobic interaction chromatography, and gel filtration. The purified enzyme gave a single protein and activity band on nondenaturing polyacrylamide gel electrophoresis and had a molecular mass of 230,000 Da. The 230-kDa enzyme was composed of large (L; 75-kDa), medium (M; 28.4-kDa), and small (S; 17.2-kDa) subunits occurring in heterohexameric (LMS)2 subunit composition. The 75-kDa polypeptide exhibited immunological cross-reactivity with the large subunit of the CODH of Oligotropha carboxidovorans. The B. japonicum enzyme contained, per mole, 2.29 atoms of Mo, 7.96 atoms of Fe, 7.60 atoms of labile S, and 1.99 mol of flavin. Treatment of the enzyme with iodoacetamide yielded di(carboxamidomethyl)molybdopterin cytosine dinucleotide, identifying molybdopterin cytosine dinucleotide as the organic portion of the B. japonicum CODH molybdenum cofactor. The absorption spectrum of the purified enzyme was characteristic of a molybdenum-containing iron-sulfur flavoprotein. PMID:10788353

  9. Carbon monoxide dehydrogenase activity in Bradyrhizobium japonicum.

    PubMed

    Lorite, M J; Tachil, J; Sanjuán, J; Meyer, O; Bedmar, E J

    2000-05-01

    Bradyrhizobium japonicum strain 110spc4 was capable of chemolithoautotrophic growth with carbon monoxide (CO) as a sole energy and carbon source under aerobic conditions. The enzyme carbon monoxide dehydrogenase (CODH; EC 1.2.99.2) has been purified 21-fold, with a yield of 16% and a specific activity of 58 nmol of CO oxidized/min/mg of protein, by a procedure that involved differential ultracentrifugation, anion-exchange chromatography, hydrophobic interaction chromatography, and gel filtration. The purified enzyme gave a single protein and activity band on nondenaturing polyacrylamide gel electrophoresis and had a molecular mass of 230,000 Da. The 230-kDa enzyme was composed of large (L; 75-kDa), medium (M; 28.4-kDa), and small (S; 17.2-kDa) subunits occurring in heterohexameric (LMS)(2) subunit composition. The 75-kDa polypeptide exhibited immunological cross-reactivity with the large subunit of the CODH of Oligotropha carboxidovorans. The B. japonicum enzyme contained, per mole, 2.29 atoms of Mo, 7.96 atoms of Fe, 7.60 atoms of labile S, and 1.99 mol of flavin. Treatment of the enzyme with iodoacetamide yielded di(carboxamidomethyl)molybdopterin cytosine dinucleotide, identifying molybdopterin cytosine dinucleotide as the organic portion of the B. japonicum CODH molybdenum cofactor. The absorption spectrum of the purified enzyme was characteristic of a molybdenum-containing iron-sulfur flavoprotein.

  10. Carbon monoxide kinetics following simulated cigarette smoking

    SciTech Connect

    Karnik, A.S.; Coin, E.J.

    1980-05-01

    Carbon monoxide kinetics were measured in the blood (% carboxyhemoglobin) and alveolar phase (ppM carbon monoxide) after simulated cigarette smoking. Cigarette smoking was siumlated using the same amount of carbon monoxide that 2R1F cigarettes manufactured by the Tobacco Research Institute would contain. Ten boluses of air containing carbon monoxide equivalent to smoking one cigarette were inhaled by six healthy nonsmoker volunteers. Carbon monoxide in the air phase was measured by an Ecolyzer and carboxyhemoglobin was measured by a CO-Oximeter. The mean rise in alveolar carbon monoxide immediately and 20 min after inhaling the last bolus was 3.3 and 3.1 ppM, respectively (p<.005). The mean rise in carboxyhemoglobin immediately and 20 min after inhalation of the last bolus was 0.8 and 0.5% respectively (P<.005). The changes in carboxyhemoglobin were found to be similar to changes that occur when one cigarette is actually smoked.

  11. 40 CFR 52.1581 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—The September 28, 1995 revision to the carbon monoxide state... Quality Standard for carbon monoxide through the year 2007. (b) The base year carbon monoxide...

  12. 21 CFR 862.3220 - Carbon monoxide test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Carbon monoxide test system. 862.3220 Section 862....3220 Carbon monoxide test system. (a) Identification. A carbon monoxide test system is a device intended to measure carbon monoxide or carboxyhemoglobin (carbon monoxide bound to the hemoglobin in...

  13. 40 CFR 52.1581 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—The September 28, 1995 revision to the carbon monoxide state... Quality Standard for carbon monoxide through the year 2007. (b) The base year carbon monoxide...

  14. 21 CFR 862.3220 - Carbon monoxide test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Carbon monoxide test system. 862.3220 Section 862....3220 Carbon monoxide test system. (a) Identification. A carbon monoxide test system is a device intended to measure carbon monoxide or carboxyhemoglobin (carbon monoxide bound to the hemoglobin in...

  15. 21 CFR 862.3220 - Carbon monoxide test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Carbon monoxide test system. 862.3220 Section 862....3220 Carbon monoxide test system. (a) Identification. A carbon monoxide test system is a device intended to measure carbon monoxide or carboxyhemoglobin (carbon monoxide bound to the hemoglobin in...

  16. 21 CFR 862.3220 - Carbon monoxide test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Carbon monoxide test system. 862.3220 Section 862....3220 Carbon monoxide test system. (a) Identification. A carbon monoxide test system is a device intended to measure carbon monoxide or carboxyhemoglobin (carbon monoxide bound to the hemoglobin in...

  17. 40 CFR 52.1581 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—The September 28, 1995 revision to the carbon monoxide state... Quality Standard for carbon monoxide through the year 2007. (b) The base year carbon monoxide...

  18. 21 CFR 862.3220 - Carbon monoxide test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Carbon monoxide test system. 862.3220 Section 862....3220 Carbon monoxide test system. (a) Identification. A carbon monoxide test system is a device intended to measure carbon monoxide or carboxyhemoglobin (carbon monoxide bound to the hemoglobin in...

  19. 40 CFR 52.1581 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—The September 28, 1995 revision to the carbon monoxide state... Quality Standard for carbon monoxide through the year 2007. (b) The base year carbon monoxide...

  20. 40 CFR 52.1581 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—The September 28, 1995 revision to the carbon monoxide state... Quality Standard for carbon monoxide through the year 2007. (b) The base year carbon monoxide...

  1. Method of removing carbon monoxide from gases

    DOEpatents

    Gerstein, Bernard C.; Macaulay, David B.

    1976-06-01

    A process and catalyst are disclosed for purifying an atmosphere containing carbon monoxide by passing the atmosphere through a bed of a catalyst of TbO.sub.x, where x = 1.8 to 1.5, which oxidizes the carbon monoxide to carbon dioxide.

  2. Environmental carbon monoxide related to pregnancy hypertension.

    PubMed

    Vigeh, Mohsen; Yunesian, Masoud; Shariat, Mamak; Niroomanesh, Shireen; Ramezanzadeh, Fateme

    2011-11-30

    Carbon monoxide pollution frequently occurs due to auto exhaust, industrial emissions, and/or cigarette smoke. Exogenous and endogenous carbon monoxide affects blood pressure; however, the relation of carbon monoxide exposure to pregnancy hypertension has not been systematically examined. For the present study the authors recruited a total of 2,707 apparently healthy, non-obese, non-smoking mothers, aged between 15 and 40 years, who had singleton births, and who lived within two miles of the selected air monitoring stations in Tehran, Iran, to study the relation of ambient carbon monoxide to pregnancy hypertension (>140 mmHg systolic and/or >90 mmHg diastolic after the 20th week of gestation). A relatively small but statistically significant elevation in mean postpartum diastolic blood pressure (mean ± SD, 69.5 ± 9.8 mmHg) was observed in the mothers' who were exposed to relatively high ambient carbon monoxide (mean = 14.1 ppm) compared to mothers exposed to lower carbon monoxide (mean = 1.8 ppm) concentrations (mean ± SD, 68.0 ± 8.3 mmHg, p < 0.01). The authors found twice the rate of pregnancy hypertension in the relatively higher carbon monoxide exposed mothers than the mothers with lower exposure (adjusted odds ratio = 2.02, 95% CI 1.35-3.03). Findings of the present study suggest that high level ambient carbon monoxide exposure is associated with pregnancy hypertension.

  3. Mars - Microwave detection of carbon monoxide

    NASA Technical Reports Server (NTRS)

    Kakar, R. K.; Walters, J. W.; Wilson, W. J.

    1977-01-01

    The 115-gigahertz microwave line of carbon monoxide has been detected in the spectrum of Mars. The measurement is sensitive to carbon monoxide between the surface and an altitude of approximately 50 kilometers in the Martian atmosphere. This extends the altitude region to well above that previously sensed.

  4. The Carbon Monoxide Tape Recorder

    NASA Technical Reports Server (NTRS)

    Schoeberl, M. R.; Duncan, B. N.; Douglass, A. R.; Waters, J.; Livesey, N.; Read, W.; Filipiak, M.

    2006-01-01

    Using Aura MLS data we have identified the stratospheric tape recorder in carbon monoxide (CO). Unlike the water vapor tape recorder, which is controlled by upper troposphere processes, the CO tape recorder is linked to seasonal biomass burning. Since CO has a lifetime of only a few months, the CO tape recorder barely extends above 20 km. The tape head for CO appears to be close to 360K near the same location as the water vapor tape head [Read et al, 20041. Both tape heads are below the equatorial cold point tropopause but above the base of the tropical tropopause layer. The tape recorder signal becomes more distinct from 360K to 380K suggesting that convective detrainment of plays a decreasingly important role with altitude. The Global Modeling Initiative chemical transport model forced by the climatology of biomass burning reproduces the CO tape recorder.

  5. Polymer-Based Carbon Monoxide Sensors

    NASA Technical Reports Server (NTRS)

    Homer, M. L.; Shevade, A. V.; Zhou, H.; Kisor, A. K.; Lara, L. M.; Yen, S.-P. S.; Ryan, M. A.

    2010-01-01

    Polymer-based sensors have been used primarily to detect volatile organics and inorganics; they are not usually used for smaller, gas phase molecules. We report the development and use of two types of polymer-based sensors for the detection of carbon monoxide. Further understanding of the experimental results is also obtained by performing molecular modeling studies to investigate the polymer-carbon monoxide interactions. The first type is a carbon-black-polymer composite that is comprised of a non-conducting polymer base that has been impregnated with carbon black to make it conducting. These chemiresistor sensors show good response to carbon monoxide but do not have a long lifetime. The second type of sensor has a non-conducting polymer base but includes both a porphyrin-functionalized polypyrrole and carbon black. These sensors show good, repeatable and reversible response to carbon monoxide at room temperature.

  6. Engineering evidence for carbon monoxide toxicity cases.

    PubMed

    Galatsis, Kosmas

    2016-07-01

    Unintentional carbon monoxide poisonings and fatalities lead to many toxicity cases. Given the unusual physical properties of carbon monoxide-in that the gas is odorless and invisible-unorganized and erroneous methods in obtaining engineering evidence as required during the discovery process often occurs. Such evidence gathering spans domains that include building construction, appliance installation, industrial hygiene, mechanical engineering, combustion and physics. In this paper, we attempt to place a systematic framework that is relevant to key aspects in engineering evidence gathering for unintentional carbon monoxide poisoning cases. Such a framework aims to increase awareness of this process and relevant issues to help guide legal counsel and expert witnesses.

  7. Carbon monoxide and the burning earth

    SciTech Connect

    Newell, R.E.; Reichle, H.G. Jr.; Seiler, W.

    1989-10-01

    Carbon monoxide is one of many gases whose presence in the atmosphere is blamed largely on industrial activity in the Northern Hemisphere. Data collected by the authors show that the gas is also abundant in the Southern Hemisphere, where it comes mainly from the burning of tropical rain forests and savannas. The high levels of carbon monoxide confirm other evidence that the rain forests are being diminished rapidly, which may affect the climates of these regions as well as globally. Increases in carbon monoxide could also encourage the accumulation of pollutant gases such as ozone and methane. The first is highly toxic to plants and the second would add to the greenhouse effect.

  8. 40 CFR 52.1237 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) The base year carbon monoxide emission inventory requirement of section 187... Metropolitan Area and Minneapolis-St. Paul Metropolitan Area. (b) Approval—The 1993 carbon monoxide...

  9. 40 CFR 52.1682 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) Approval—The November 13, 1992 revision to the carbon monoxide state implementation... attainment of the National Ambient Air Quality Standard for carbon monoxide through the year 2003....

  10. 40 CFR 52.2353 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. Determination. EPA has determined that the Provo carbon monoxide “moderate” nonattainment area attained the carbon monoxide national ambient air quality standard by December 31, 1995....

  11. 40 CFR 52.1237 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) The base year carbon monoxide emission inventory requirement of section 187... Metropolitan Area and Minneapolis-St. Paul Metropolitan Area. (b) Approval—The 1993 carbon monoxide...

  12. 40 CFR 91.317 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Carbon monoxide analyzer calibration... Provisions § 91.317 Carbon monoxide analyzer calibration. (a) Calibrate the NDIR carbon monoxide analyzer... service and annually thereafter, check the NDIR carbon monoxide analyzer for response to water vapor...

  13. 21 CFR 177.1312 - Ethylene-carbon monoxide copolymers.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Ethylene-carbon monoxide copolymers. 177.1312... Use Food Contact Surfaces § 177.1312 Ethylene-carbon monoxide copolymers. The ethylene-carbon monoxide... of this section, ethylene-carbon monoxide copolymers (CAS Reg. No. 25052-62-4) consist of the...

  14. 40 CFR 52.1682 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) Approval—The November 13, 1992 revision to the carbon monoxide state implementation... attainment of the National Ambient Air Quality Standard for carbon monoxide through the year 2003....

  15. 40 CFR 52.1237 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) The base year carbon monoxide emission inventory requirement of section 187... Metropolitan Area and Minneapolis-St. Paul Metropolitan Area. (b) Approval—The 1993 carbon monoxide...

  16. 40 CFR 52.1682 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) Approval—The November 13, 1992 revision to the carbon monoxide state implementation... attainment of the National Ambient Air Quality Standard for carbon monoxide through the year 2003....

  17. 40 CFR 52.2353 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. Determination. EPA has determined that the Provo carbon monoxide “moderate” nonattainment area attained the carbon monoxide national ambient air quality standard by December 31, 1995....

  18. 40 CFR 52.1682 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) Approval—The November 13, 1992 revision to the carbon monoxide state implementation... attainment of the National Ambient Air Quality Standard for carbon monoxide through the year 2003....

  19. 40 CFR 52.2353 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. Determination. EPA has determined that the Provo carbon monoxide “moderate” nonattainment area attained the carbon monoxide national ambient air quality standard by December 31, 1995....

  20. 40 CFR 52.1682 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) Approval—The November 13, 1992 revision to the carbon monoxide state implementation... attainment of the National Ambient Air Quality Standard for carbon monoxide through the year 2003....

  1. 40 CFR 52.2353 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. Determination. EPA has determined that the Provo carbon monoxide “moderate” nonattainment area attained the carbon monoxide national ambient air quality standard by December 31, 1995....

  2. 40 CFR 52.1237 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) The base year carbon monoxide emission inventory requirement of section 187... Metropolitan Area and Minneapolis-St. Paul Metropolitan Area. (b) Approval—The 1993 carbon monoxide...

  3. 40 CFR 52.1237 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) The base year carbon monoxide emission inventory requirement of section 187... Metropolitan Area and Minneapolis-St. Paul Metropolitan Area. (b) Approval—The 1993 carbon monoxide...

  4. 40 CFR 91.317 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Carbon monoxide analyzer calibration... Provisions § 91.317 Carbon monoxide analyzer calibration. (a) Calibrate the NDIR carbon monoxide analyzer... service and annually thereafter, check the NDIR carbon monoxide analyzer for response to water vapor...

  5. 40 CFR 52.2353 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. Determination. EPA has determined that the Provo carbon monoxide “moderate” nonattainment area attained the carbon monoxide national ambient air quality standard by December 31, 1995....

  6. Device for staged carbon monoxide oxidation

    DOEpatents

    Vanderborgh, Nicholas E.; Nguyen, Trung V.; Guante, Jr., Joseph

    1993-01-01

    A method and apparatus for selectively oxidizing carbon monoxide in a hydrogen rich feed stream. The method comprises mixing a feed stream consisting essentially of hydrogen, carbon dioxide, water and carbon monoxide with a first predetermined quantity of oxygen (air). The temperature of the mixed feed/oxygen stream is adjusted in a first the heat exchanger assembly (20) to a first temperature. The mixed feed/oxygen stream is sent to reaction chambers (30,32) having an oxidation catalyst contained therein. The carbon monoxide of the feed stream preferentially absorbs on the catalyst at the first temperature to react with the oxygen in the chambers (30,32) with minimal simultaneous reaction of the hydrogen to form an intermediate hydrogen rich process stream having a lower carbon monoxide content than the feed stream. The elevated outlet temperature of the process stream is carefully controlled in a second heat exchanger assembly (42) to a second temperature above the first temperature. The process stream is then mixed with a second predetermined quantity of oxygen (air). The carbon monoxide of the process stream preferentially reacts with the second quantity of oxygen in a second stage reaction chamber (56) with minimal simultaneous reaction of the hydrogen in the process stream. The reaction produces a hydrogen rich product stream having a lower carbon monoxide content than the process stream. The product stream is then cooled in a third heat exchanger assembly (72) to a third predetermined temperature. Three or more stages may be desirable, each with metered oxygen injection.

  7. Aging Factsheets: Carbon Monoxide Poisoning Prevention

    EPA Pesticide Factsheets

    Everyone is at risk of being poisoned by carbon monoxide exposure. Older adults with pre-existing conditions, such as chronic heart disease, anemia, or respiratory problems, are even more susceptible to the effects of this odorless, colorless gas.

  8. A Fluorescent Source NDIR Carbon Monoxide Analyzer

    NASA Technical Reports Server (NTRS)

    Link, W. T.; McClatchie, E. A.; Watson, D. A.; Compher, A. B.

    1971-01-01

    This paper describes a new technique for measuring trace quantities of carbon monoxide by the nondispersive infrared (NDIR) methods. The technique uses the property of infrared fluorescence in a gas to generate a specific source of radiation which is an exact match of the absorption spectrum of the fundamental band of carbon monoxide. This results in an instrument with high sensitivity and specificity for CO. A novel method of referencing using an isotopic species of CO confers great stability on the instrument.

  9. Carbon monoxide sensor and method of use

    DOEpatents

    Dutta, Prabir K.; Swartz, Scott L.; Holt, Christopher T.; Revur, Ramachandra Rao

    2006-01-10

    A sensor and method of use for detection of low levels of carbon monoxide in gas mixtures. The approach is based on the change in an electrical property (for example: resistance) that occurs when carbon monoxide is selectively absorbed by a film of copper chloride (or other metal halides). The electrical property change occurs rapidly with both increasing and decreasing CO contents, varies with the amount of CO from the gas stream, and is insensitive to the presence of hydrogen. To make a sensor using this approach, the metal halide film will deposited onto an alumina substrate with electrodes. The sensor may be maintained at the optimum temperature with a thick film platinum heater deposited onto the opposite face of the substrate. When the sensor is operating at an appropriate (and constant) temperature, the magnitude of the electrical property measured between the interdigital electrodes will provide a measure of the carbon monoxide content of the gas.

  10. 40 CFR 89.320 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Carbon monoxide analyzer calibration... Test Equipment Provisions § 89.320 Carbon monoxide analyzer calibration. (a) Calibrate the NDIR carbon... introduction into service and annually thereafter, the NDIR carbon monoxide analyzer shall be checked...

  11. 40 CFR 89.320 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Carbon monoxide analyzer calibration... Test Equipment Provisions § 89.320 Carbon monoxide analyzer calibration. (a) Calibrate the NDIR carbon... introduction into service and annually thereafter, the NDIR carbon monoxide analyzer shall be checked...

  12. 40 CFR 89.320 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Carbon monoxide analyzer calibration... Test Equipment Provisions § 89.320 Carbon monoxide analyzer calibration. (a) Calibrate the NDIR carbon... introduction into service and annually thereafter, the NDIR carbon monoxide analyzer shall be checked...

  13. 40 CFR 52.1887 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) Part D—Approval—The following portions of the Ohio plan are approved: (1) The carbon...) The carbon monoxide attainment and reasonable further progress demonstrations for the following...

  14. 40 CFR 52.1887 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) Part D—Approval—The following portions of the Ohio plan are approved: (1) The carbon...) The carbon monoxide attainment and reasonable further progress demonstrations for the following...

  15. 40 CFR 52.1887 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) Part D—Approval—The following portions of the Ohio plan are approved: (1) The carbon...) The carbon monoxide attainment and reasonable further progress demonstrations for the following...

  16. 40 CFR 52.1887 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) Part D—Approval—The following portions of the Ohio plan are approved: (1) The carbon...) The carbon monoxide attainment and reasonable further progress demonstrations for the following...

  17. 40 CFR 89.320 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Carbon monoxide analyzer calibration... Test Equipment Provisions § 89.320 Carbon monoxide analyzer calibration. (a) Calibrate the NDIR carbon... introduction into service and annually thereafter, the NDIR carbon monoxide analyzer shall be checked...

  18. 40 CFR 86.1322-84 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Carbon monoxide analyzer calibration... Exhaust Test Procedures § 86.1322-84 Carbon monoxide analyzer calibration. The NDIR carbon monoxide... interference check. Prior to its introduction into service and annually thereafter, the NDIR carbon...

  19. 40 CFR 89.320 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Carbon monoxide analyzer calibration... Test Equipment Provisions § 89.320 Carbon monoxide analyzer calibration. (a) Calibrate the NDIR carbon... introduction into service and annually thereafter, the NDIR carbon monoxide analyzer shall be checked...

  20. 40 CFR 52.1887 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) Part D—Approval—The following portions of the Ohio plan are approved: (1) The carbon...) The carbon monoxide attainment and reasonable further progress demonstrations for the following...

  1. [Carbon monoxide poisoning in children: never trivialize].

    PubMed

    Scalfaro, P; Haenggi, M H; Roulet, E; Gehri, M; Stucki, P; Schaller, M D; Cotting, J

    2000-03-01

    The risks linked to tissular hypoxemia after carbon monoxide (CO) poisoning are well known. Unawareness of CO exposure and of its complex pathophysiology may delay appropriate treatment and lead to long term neuropsychological sequelae. We report two cases of children treated in our institution and review the main issues regarding the optimal management. A high index of suspicion for carbon monoxide poisoning when dealing with an unclear neurological clinical presentation is mandatory. Classical therapy with normobaric 100% oxygen has to be instaured immediately. Hyperbaric oxygen therapy must be considered when anamnestic symptoms or clinical signs suggest neurological involvement even when carboxyhemoglobin values are low or already normalized.

  2. Enhanced carbon monoxide utilization in methanation process

    DOEpatents

    Elek, Louis F.; Frost, Albert C.

    1984-01-01

    Carbon monoxide - containing gas streams are passed over a catalyst to deposit a surface layer of active surface carbon thereon essentially without the formation of inactive coke. The active carbon is subsequently reacted with steam or hydrogen to form methane. Surprisingly, hydrogen and water vapor present in the feed gas do not adversely affect CO utilization significantly, and such hydrogen actually results in a significant increase in CO utilization.

  3. [Carbon monoxide metabolism by photosynthetic bacteria]. Progress report

    SciTech Connect

    Not Available

    1989-12-31

    Research continued on the metabolism of carbon monoxide by Rhodospirillum rubrum. This report discusses progress on the activity, induction, inhibition, and spectroscopic analysis of the enzyme Carbon Monoxide Dehydrogenase. (CBS)

  4. CPSC Warns of Carbon Monoxide Poisoning with Camping Equipment

    MedlinePlus

    ... Warns of Carbon Monoxide Poisoning Hazard with Camping Equipment The U.S. Consumer Product Safety Commission (CPSC) warns ... about the carbon monoxide (CO) hazard with camping equipment. CO can kill you! From 2002–2006, CPSC ...

  5. 21 CFR 868.1430 - Carbon monoxide gas analyzer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Carbon monoxide gas analyzer. 868.1430 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1430 Carbon monoxide gas analyzer. (a) Identification. A carbon monoxide gas analyzer is a device intended to measure the concentration of...

  6. 40 CFR 52.1185 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) Approval—On November 24, 1994, the Michigan Department of Natural Resources submitted a revision to the carbon monoxide State Implementation Plan. The submittal pertained to a plan...

  7. 40 CFR 52.1132 - Control strategy: Carbon Monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon Monoxide. 52... strategy: Carbon Monoxide. (a) Approval—On November 13, 1992, the Massachusetts Department of Environmental Protection submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base...

  8. 21 CFR 177.1312 - Ethylene-carbon monoxide copolymers.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ethylene-carbon monoxide copolymers. 177.1312... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1312 Ethylene-carbon monoxide copolymers. The ethylene-carbon monoxide copolymers identified in paragraph (a) of this section may be...

  9. 40 CFR 52.349 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.349 Control strategy: Carbon monoxide. (a) Revisions to the Colorado State Implementation Plan, Carbon Monoxide Redesignation...

  10. 21 CFR 177.1312 - Ethylene-carbon monoxide copolymers.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Ethylene-carbon monoxide copolymers. 177.1312... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1312 Ethylene-carbon monoxide copolymers. The ethylene-carbon monoxide copolymers identified in paragraph (a) of this section may be...

  11. 40 CFR 52.1373 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) On July 8, 1997, the Governor of Montana submitted revisions to the SIP narrative for the Missoula carbon monoxide control plan. (b) Revisions to the Montana State Implementation...

  12. 40 CFR 52.1185 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) Approval—On November 24, 1994, the Michigan Department of Natural Resources submitted a revision to the carbon monoxide State Implementation Plan. The submittal pertained to a plan...

  13. 40 CFR 52.1373 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) On July 8, 1997, the Governor of Montana submitted revisions to the SIP narrative for the Missoula carbon monoxide control plan. (b) Revisions to the Montana State Implementation...

  14. 75 FR 4815 - Integrated Science Assessment for Carbon Monoxide

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-29

    ... AGENCY Integrated Science Assessment for Carbon Monoxide AGENCY: Environmental Protection Agency (EPA... availability of a final document titled, ``Integrated Science Assessment for Carbon Monoxide'' (EPA/600/R-09... standards (NAAQS) for carbon monoxide. DATES: The document will be available on January 29, 2010....

  15. 40 CFR 52.1528 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—On February 1, 1999, the New Hampshire Department of Environmental... program for carbon monoxide that ceased operating on January 1, 1995. The Nashua...

  16. 21 CFR 868.1430 - Carbon monoxide gas analyzer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Carbon monoxide gas analyzer. 868.1430 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1430 Carbon monoxide gas analyzer. (a) Identification. A carbon monoxide gas analyzer is a device intended to measure the concentration of...

  17. 40 CFR 86.522-78 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Carbon monoxide analyzer calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.522-78 Carbon monoxide analyzer... thereafter the NDIR carbon monoxide analyzer shall be checked for response to water vapor and CO2: (1)...

  18. 40 CFR 86.122-78 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Carbon monoxide analyzer calibration... Complete Heavy-Duty Vehicles; Test Procedures § 86.122-78 Carbon monoxide analyzer calibration. The NDIR carbon monoxide analyzer shall receive the following initial and periodic calibrations: (a) Initial...

  19. 40 CFR 86.522-78 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Carbon monoxide analyzer calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.522-78 Carbon monoxide analyzer... thereafter the NDIR carbon monoxide analyzer shall be checked for response to water vapor and CO2: (1)...

  20. 40 CFR 52.1373 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) On July 8, 1997, the Governor of Montana submitted revisions to the SIP narrative for the Missoula carbon monoxide control plan. (b) Revisions to the Montana State Implementation...

  1. 40 CFR 52.349 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.349 Control strategy: Carbon monoxide. (a) Revisions to the Colorado State Implementation Plan, Carbon Monoxide Redesignation...

  2. 40 CFR 52.1528 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—On February 1, 1999, the New Hampshire Department of Environmental... program for carbon monoxide that ceased operating on January 1, 1995. The Nashua...

  3. 40 CFR 52.1373 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) On July 8, 1997, the Governor of Montana submitted revisions to the SIP narrative for the Missoula carbon monoxide control plan. (b) Revisions to the Montana State Implementation...

  4. 40 CFR 52.1185 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) Approval—On November 24, 1994, the Michigan Department of Natural Resources submitted a revision to the carbon monoxide State Implementation Plan. The submittal pertained to a plan...

  5. 21 CFR 868.1430 - Carbon monoxide gas analyzer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Carbon monoxide gas analyzer. 868.1430 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1430 Carbon monoxide gas analyzer. (a) Identification. A carbon monoxide gas analyzer is a device intended to measure the concentration of...

  6. 21 CFR 868.1430 - Carbon monoxide gas analyzer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Carbon monoxide gas analyzer. 868.1430 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1430 Carbon monoxide gas analyzer. (a) Identification. A carbon monoxide gas analyzer is a device intended to measure the concentration of...

  7. 40 CFR 52.1373 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) On July 8, 1997, the Governor of Montana submitted revisions to the SIP narrative for the Missoula carbon monoxide control plan. (b) Revisions to the Montana State Implementation...

  8. 40 CFR 52.1528 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—On February 1, 1999, the New Hampshire Department of Environmental... program for carbon monoxide that ceased operating on January 1, 1995. The Nashua...

  9. 40 CFR 52.1132 - Control strategy: Carbon Monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Carbon Monoxide. 52... strategy: Carbon Monoxide. (a) Approval—On November 13, 1992, the Massachusetts Department of Environmental Protection submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base...

  10. 40 CFR 52.1185 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) Approval—On November 24, 1994, the Michigan Department of Natural Resources submitted a revision to the carbon monoxide State Implementation Plan. The submittal pertained to a plan...

  11. 40 CFR 86.522-78 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Carbon monoxide analyzer calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.522-78 Carbon monoxide analyzer... thereafter the NDIR carbon monoxide analyzer shall be checked for response to water vapor and CO2: (1)...

  12. 40 CFR 52.1132 - Control strategy: Carbon Monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon Monoxide. 52... strategy: Carbon Monoxide. (a) Approval—On November 13, 1992, the Massachusetts Department of Environmental Protection submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base...

  13. 40 CFR 52.1185 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) Approval—On November 24, 1994, the Michigan Department of Natural Resources submitted a revision to the carbon monoxide State Implementation Plan. The submittal pertained to a plan...

  14. 40 CFR 52.349 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.349 Control strategy: Carbon monoxide. (a) Revisions to the Colorado State Implementation Plan, Carbon Monoxide Redesignation...

  15. 40 CFR 86.522-78 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Carbon monoxide analyzer calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.522-78 Carbon monoxide analyzer... thereafter the NDIR carbon monoxide analyzer shall be checked for response to water vapor and CO2: (1)...

  16. 40 CFR 52.349 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.349 Control strategy: Carbon monoxide. (a) Revisions to the Colorado State Implementation Plan, Carbon Monoxide Redesignation...

  17. 40 CFR 90.317 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Carbon monoxide analyzer calibration... Emission Test Equipment Provisions § 90.317 Carbon monoxide analyzer calibration. (a) Calibrate the NDIR carbon monoxide analyzer as described in this section. (b) Initial and periodic interference. Prior...

  18. 40 CFR 52.1132 - Control strategy: Carbon Monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon Monoxide. 52... strategy: Carbon Monoxide. (a) Approval—On November 13, 1992, the Massachusetts Department of Environmental Protection submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base...

  19. 21 CFR 868.1430 - Carbon monoxide gas analyzer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Carbon monoxide gas analyzer. 868.1430 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1430 Carbon monoxide gas analyzer. (a) Identification. A carbon monoxide gas analyzer is a device intended to measure the concentration of...

  20. 21 CFR 177.1312 - Ethylene-carbon monoxide copolymers.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Ethylene-carbon monoxide copolymers. 177.1312... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1312 Ethylene-carbon monoxide copolymers. The ethylene-carbon monoxide copolymers identified in paragraph (a) of this section may be...

  1. 40 CFR 52.1528 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—On February 1, 1999, the New Hampshire Department of Environmental... program for carbon monoxide that ceased operating on January 1, 1995. The Nashua...

  2. 40 CFR 52.349 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.349 Control strategy: Carbon monoxide. (a) Revisions to the Colorado State Implementation Plan, Carbon Monoxide Redesignation...

  3. 40 CFR 52.1132 - Control strategy: Carbon Monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon Monoxide. 52... strategy: Carbon Monoxide. (a) Approval—On November 13, 1992, the Massachusetts Department of Environmental Protection submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base...

  4. 40 CFR 52.1528 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—On February 1, 1999, the New Hampshire Department of Environmental... program for carbon monoxide that ceased operating on January 1, 1995. The Nashua...

  5. 40 CFR 90.317 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Carbon monoxide analyzer calibration... Emission Test Equipment Provisions § 90.317 Carbon monoxide analyzer calibration. (a) Calibrate the NDIR carbon monoxide analyzer as described in this section. (b) Initial and periodic interference. Prior...

  6. 21 CFR 177.1312 - Ethylene-carbon monoxide copolymers.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Ethylene-carbon monoxide copolymers. 177.1312... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1312 Ethylene-carbon monoxide copolymers. The ethylene-carbon monoxide copolymers identified in paragraph (a) of this section may be...

  7. Carbon Monoxide, A Bibliography With Abstracts.

    ERIC Educational Resources Information Center

    Cooper, Anna Grossman

    Included is a review of the carbon monoxide related literature published from 1880 to 1966. The 983 references with abstracts are grouped into these broad categories: Analysis, Biological Effects, Blood Chemistry, Control, Criteria and Standards, Instruments and Techniques, Sampling and Network Operations, and Sources. The Biological Effects group…

  8. Neurological manifestation of carbon monoxide poisoning.

    PubMed Central

    Hart, I. K.; Kennedy, P. G.; Adams, J. H.; Cunningham, N. E.

    1988-01-01

    The clinical signs and post-mortem findings in a case of carbon monoxide poisoning are described, and correlated with the computer tomographic (CT) scan appearances. The value of serial CT scanning as a diagnostic tool is highlighted. Images Figure 1 Figure 2 PMID:3174539

  9. Method and apparatus for selective removal of carbon monoxide

    DOEpatents

    Borup, Rodney L.; Skala, Glenn W.; Brundage, Mark A.; LaBarge, William J.

    2000-01-01

    There is provided a method and apparatus for treatment of a hydrogen-rich gas to reduce the carbon monoxide content thereof by reacting the carbon monoxide in the gas with an amount of oxygen sufficient to oxidize at least a portion of the carbon monoxide in the presence of a catalyst in a desired temperature range without substantial reaction of hydrogen. The catalyst is an iridium-based catalyst dispersed on, and supported on, a carrier. In the presence of the catalyst, carbon monoxide in a hydrogen-rich feed gas is selectively oxidized such that a product stream is produced with a very low carbon monoxide content.

  10. 40 CFR 86.316-79 - Carbon monoxide and carbon dioxide analyzer specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Carbon monoxide and carbon dioxide... Test Procedures § 86.316-79 Carbon monoxide and carbon dioxide analyzer specifications. (a) Carbon monoxide and carbon dioxide measurements are to be made with nondispersive infrared (NDIR) an analyzers....

  11. 40 CFR 86.316-79 - Carbon monoxide and carbon dioxide analyzer specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Carbon monoxide and carbon dioxide... Test Procedures § 86.316-79 Carbon monoxide and carbon dioxide analyzer specifications. (a) Carbon monoxide and carbon dioxide measurements are to be made with nondispersive infrared (NDIR) an analyzers....

  12. 40 CFR 86.316-79 - Carbon monoxide and carbon dioxide analyzer specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Carbon monoxide and carbon dioxide... Test Procedures § 86.316-79 Carbon monoxide and carbon dioxide analyzer specifications. (a) Carbon monoxide and carbon dioxide measurements are to be made with nondispersive infrared (NDIR) an analyzers....

  13. 40 CFR 86.316-79 - Carbon monoxide and carbon dioxide analyzer specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Carbon monoxide and carbon dioxide... Test Procedures § 86.316-79 Carbon monoxide and carbon dioxide analyzer specifications. (a) Carbon monoxide and carbon dioxide measurements are to be made with nondispersive infrared (NDIR) an analyzers....

  14. 40 CFR 52.729 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.729 Control strategy: Carbon..., Illinois be granted a carbon monoxide (CO) state implementation plan (SIP) revision with...

  15. 40 CFR 60.263 - Standard for carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for carbon monoxide. 60.263... Production Facilities § 60.263 Standard for carbon monoxide. (a) On and after the date on which the... furnace any gases which contain, on a dry basis, 20 or greater volume percent of carbon...

  16. 40 CFR 52.729 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.729 Control strategy: Carbon..., Illinois be granted a carbon monoxide (CO) state implementation plan (SIP) revision with...

  17. 40 CFR 52.376 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.376 Control strategy: Carbon... submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base year...

  18. 40 CFR 60.263 - Standard for carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for carbon monoxide. 60.263... Production Facilities § 60.263 Standard for carbon monoxide. (a) On and after the date on which the... furnace any gases which contain, on a dry basis, 20 or greater volume percent of carbon...

  19. 40 CFR 52.729 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.729 Control strategy: Carbon..., Illinois be granted a carbon monoxide (CO) state implementation plan (SIP) revision with...

  20. 40 CFR 52.785 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.785 Control strategy: Carbon... for attainment and maintenance of the national standards for carbon monoxide in the...

  1. 40 CFR 52.376 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.376 Control strategy: Carbon... submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base year...

  2. 40 CFR 52.376 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.376 Control strategy: Carbon... submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base year...

  3. 40 CFR 52.376 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.376 Control strategy: Carbon... submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base year...

  4. 40 CFR 60.263 - Standard for carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for carbon monoxide. 60.263... Production Facilities § 60.263 Standard for carbon monoxide. (a) On and after the date on which the... furnace any gases which contain, on a dry basis, 20 or greater volume percent of carbon...

  5. 40 CFR 52.785 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.785 Control strategy: Carbon... for attainment and maintenance of the national standards for carbon monoxide in the...

  6. 40 CFR 52.785 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.785 Control strategy: Carbon... for attainment and maintenance of the national standards for carbon monoxide in the...

  7. 40 CFR 52.376 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.376 Control strategy: Carbon... submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base year...

  8. 40 CFR 52.785 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.785 Control strategy: Carbon... for attainment and maintenance of the national standards for carbon monoxide in the...

  9. 40 CFR 52.785 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.785 Control strategy: Carbon... for attainment and maintenance of the national standards for carbon monoxide in the...

  10. 40 CFR 60.263 - Standard for carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for carbon monoxide. 60.263... Production Facilities § 60.263 Standard for carbon monoxide. (a) On and after the date on which the... furnace any gases which contain, on a dry basis, 20 or greater volume percent of carbon...

  11. 40 CFR 52.729 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.729 Control strategy: Carbon..., Illinois be granted a carbon monoxide (CO) state implementation plan (SIP) revision with...

  12. 40 CFR 52.729 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.729 Control strategy: Carbon..., Illinois be granted a carbon monoxide (CO) state implementation plan (SIP) revision with...

  13. 40 CFR 60.263 - Standard for carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for carbon monoxide. 60.263... Production Facilities § 60.263 Standard for carbon monoxide. (a) On and after the date on which the... furnace any gases which contain, on a dry basis, 20 or greater volume percent of carbon...

  14. CO (Carbon Monoxide Mixing Ratio System) Handbook

    SciTech Connect

    Biraud, S

    2011-02-23

    The main function of the CO instrument is to provide continuous accurate measurements of carbon monoxide mixing ratio at the ARM SGP Central Facility (CF) 60-meter tower (36.607 °N, 97.489 °W, 314 meters above sea level). The essential feature of the control and data acquisition system is to record signals from a Thermo Electron 48C and periodically calibrate out zero and span drifts in the instrument using the combination of a CO scrubber and two concentrations of span gas (100 and 300 ppb CO in air). The system was deployed on May 25, 2005.

  15. Accidental carbon monoxide poisoning in our homes.

    PubMed

    Sharma, Shruti; Gupta, Rahul; Paul, Barinder S; Puri, Sandeep; Garg, Shuchita

    2009-01-01

    Carbon monoxide (CO) is a colorless, odorless, tasteless, nonirritating, but significantly toxic gas. It is a product of combustion of organic matter in presence of insufficient oxygen supply. Symptoms of mild poisoning include headaches, vertigo and flu like effects, whereas larger exposures can lead to significant toxicity of the central nervous system (CNS), heart, and even death. We are reporting two cases that presented to us in the winter months of December to January with history, sign, symptoms, and radiological evidence of suspected CO poisoning.

  16. Integrated Science Assessment (ISA) for Carbon Monoxide ...

    EPA Pesticide Factsheets

    EPA announced the availability of the final report, Integrated Science Assessment (ISA) for Carbon Monoxide (CO). This report is EPA’s latest evaluation of the scientific literature on the potential human health and welfare effects associated with ambient exposures to CO. The development of this document is part of the Agency's periodic review of the national ambient air quality standards (NAAQS) for CO. The recently completed CO ISA and supplementary annexes, in conjunction with additional technical and policy assessments developed by EPA’s Office of Air and Radiation, will provide the scientific basis to inform EPA decisions related to the review of the current CO NAAQS. The integrated Plan for Review of the National Ambient Air Quality Standards for Carbon Monoxide (U.S. EPA, 2008, 193995) identifies key policy-relevant questions that provide a framework for this assessment of the scientific evidence. These questions frame the entire review of the NAAQS for CO and thus are informed by both science and policy considerations. The ISA organizes, presents, and integrates the scientific evidence which is considered along with findings from risk analyses and policy considerations to help the U.S. Environmental Protection Agency (EPA) address these questions during the NAAQS review.

  17. [Carbon monoxide poisoning by a heating system].

    PubMed

    Dietz, Eric; Gehl, Axel; Friedrich, Peter; Kappus, Stefan; Petter, Franz; Maurer, Klaus; Püschel, Klaus

    2016-01-01

    A case of accidental carbon monoxide poisoning in several occupants of two neighboring residential buildings in Hamburg-Harburg (Germany) caused by a defective gas central heating system is described. Because of leaks in one of the residential buildings and the directly adjacent wall of the neighboring house, the gas could spread and accumulated in both residential buildings, which resulted in a highly dangerous situation. Exposure to the toxic gas caused mild to severe intoxication in 15 persons. Three victims died still at the site of the accident. Measures to protect the occupants were taken only with a great delay. As symptoms were unspecific, it was not realized that the various alarms given by persons involved in the accident were related to the same cause. In order to take appropriate measures in time it is indispensible to recognize, assess and check potential risks, which can be done by using carbon monoxide warning devices and performing immediate COHb measurements with special pulse oximeters on site. Moreover, the COHb content in the blood should be routinely determined in all patients admitted to an emergency department with unspecific symptoms.

  18. Carbon monoxide metabolism by photosynthetic bacteria: Progress report

    SciTech Connect

    Ludden, P.W.; Roberts, G.P.

    1988-01-01

    The photosynthetic bacterium, Rhodospirillum rubrum, is capable of converting carbon monoxide to CO/sub 2/ and cellular material. Because carbon monoxide is a major industrial pollutant in this country and a product of the biological oxidation of CO is the product of H/sub 2/, a major industrial feedstock, this process has practical importance. The oxidation of carbon monoxide to CO/sub 2/ by microorganisms is a major component of the carbon monoxide cycle on earth. We have isolated the enzyme responsible for this process from Rhodospirillum rubrum. Carbon monoxide dehydrogenase is an iron - sulfur, nickel- and zinc-containing enzyme. The enzyme is quite stable to heat and amendable to purification, however, it is very labile to oxygen, and all experiments must be conducted anaerobically. We are studying the activities of this enzyme, its regulation and its induction by its substrate carbon monoxide. The enzyme is absent in cells that have not been exposed to carbon monoxide, but cells produce the enzyme at a maximal rate upon exposure to carbon monoxide for as little as ten minutes. Oxygen, a potent and irreversible inhibitor of the enzyme, represses the synthesis of this enzyme. 1 tab.

  19. 40 CFR 52.2089 - Control strategy: carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: carbon monoxide. 52... strategy: carbon monoxide. (a) Approval—On September 22, 2008, the Rhode Island Department of Environmental Management submitted a request to establish a limited maintenance plan for the Providence Rhode Island...

  20. 40 CFR 52.1179 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52.1179 Section 52.1179 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...: Carbon monoxide. (a) Approval—On March 18, 1999, the Michigan Department of Environmental...

  1. 40 CFR 52.2089 - Control strategy: carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: carbon monoxide. 52... strategy: carbon monoxide. (a) Approval—On September 22, 2008, the Rhode Island Department of Environmental Management submitted a request to establish a limited maintenance plan for the Providence Rhode Island...

  2. 40 CFR 52.1340 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52.1340 Section 52.1340 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...: Carbon monoxide. Approval—A maintenance plan and redesignation request for the St. Louis, Missouri,...

  3. 40 CFR 52.1179 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52.1179 Section 52.1179 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...: Carbon monoxide. (a) Approval—On March 18, 1999, the Michigan Department of Environmental...

  4. 40 CFR 52.1179 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52.1179 Section 52.1179 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...: Carbon monoxide. (a) Approval—On March 18, 1999, the Michigan Department of Environmental...

  5. 40 CFR 52.2089 - Control strategy: carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: carbon monoxide. 52... strategy: carbon monoxide. (a) Approval—On September 22, 2008, the Rhode Island Department of Environmental Management submitted a request to establish a limited maintenance plan for the Providence Rhode Island...

  6. 40 CFR 52.1340 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52.1340 Section 52.1340 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...: Carbon monoxide. Approval—A maintenance plan and redesignation request for the St. Louis, Missouri,...

  7. 40 CFR 52.1340 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52.1340 Section 52.1340 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...: Carbon monoxide. Approval—A maintenance plan and redesignation request for the St. Louis, Missouri,...

  8. 40 CFR 52.1340 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52.1340 Section 52.1340 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...: Carbon monoxide. Approval—A maintenance plan and redesignation request for the St. Louis, Missouri,...

  9. 40 CFR 52.2089 - Control strategy: carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: carbon monoxide. 52... strategy: carbon monoxide. (a) Approval—On September 22, 2008, the Rhode Island Department of Environmental Management submitted a request to establish a limited maintenance plan for the Providence Rhode Island...

  10. 40 CFR 52.2089 - Control strategy: carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: carbon monoxide. 52... strategy: carbon monoxide. (a) Approval—On September 22, 2008, the Rhode Island Department of Environmental Management submitted a request to establish a limited maintenance plan for the Providence Rhode Island...

  11. 40 CFR 52.1179 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52.1179 Section 52.1179 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...: Carbon monoxide. (a) Approval—On March 18, 1999, the Michigan Department of Environmental...

  12. 40 CFR 52.1340 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52.1340 Section 52.1340 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...: Carbon monoxide. Approval—A maintenance plan and redesignation request for the St. Louis, Missouri,...

  13. 40 CFR 52.1179 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52.1179 Section 52.1179 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...: Carbon monoxide. (a) Approval—On March 18, 1999, the Michigan Department of Environmental...

  14. Fatal carbon monoxide intoxication after acetylene gas welding of pipes.

    PubMed

    Antonsson, Ann-Beth; Christensson, Bengt; Berge, Johan; Sjögren, Bengt

    2013-06-01

    Acetylene gas welding of district heating pipes can result in exposure to high concentrations of carbon monoxide. A fatal case due to intoxication is described. Measurements of carbon monoxide revealed high levels when gas welding a pipe with closed ends. This fatality and these measurements highlight a new hazard, which must be promptly prevented.

  15. Real World of Industrial Chemistry: Organic Chemicals from Carbon Monoxide.

    ERIC Educational Resources Information Center

    Kolb, Kenneth E.; Kolb, Doris

    1983-01-01

    Carbon Monoxide obtained from coal may serve as the source for a wide variety of organic compounds. Several of these compounds are discussed, including phosgene, benzaldehyde, methanol, formic acid and its derivatives, oxo aldehydes, acrylic acids, and others. Commercial reactions of carbon monoxide are highlighted in a table. (JN)

  16. Carbon monoxide oxidation rates computed for automobile thermal reactor conditions

    NASA Technical Reports Server (NTRS)

    Brokaw, R. S.; Bittker, D. A.

    1972-01-01

    Carbon monoxide oxidation rates in thermal reactors for exhaust manifolds are computed by integrating differential equations for system of twenty-nine reversible chemical reactions. Reactors are noncatalytic replacements for conventional exhaust manifolds and are a system for reducing carbon monoxide and hydrocarbons in automobile exhausts.

  17. Search of medical literature for indoor carbon monoxide exposure

    SciTech Connect

    Brennan, T.; Ivanovich, M.

    1995-12-01

    This report documents a literature search on carbon monoxide. The search was limited to the medical and toxicological databases at the National Library of Medicine (MEDLARS). The databases searched were Medline, Toxline and TOXNET. Searches were performed using a variety of strategies. Combinations of the following keywords were used: carbon, monoxide, accidental, residential, occult, diagnosis, misdiagnosis, heating, furnace, and indoor. The literature was searched from 1966 to the present. Over 1000 references were identified and summarized using the following abbreviations: The major findings of the search are: (1) Acute and subacute carbon monoxide exposures result in a large number of symptoms affecting the brain, kidneys, respiratory system, retina, and motor functions. (2) Acute and subacute carbon monoxide (CO) poisonings have been misdiagnosed on many occasions. (3) Very few systematic investigations have been made into the frequency and consequences of carbon monoxide poisonings.

  18. Carbon monoxide exposure of subjects with documented cardiac arrhythmias

    SciTech Connect

    Chaitman, B.R.; Dahms, T.E.; Byers, S.; Carroll, L.W.; Younis, L.T.; Wiens, R.D. )

    1992-09-01

    The impact of low-level carbon monoxide exposure on ventricular arrhythmia frequency in patients with ischemic heart disease has not been thoroughly studied. The issue is of concern because of the potential proarrhythmic effect of carbon monoxide in patients with ischemic heart disease. We studied 30 subjects with well-documented coronary artery disease who had an average of at least 30 ventricular ectopic beats per hour over a 20-hour monitoring interval. By using appropriate inclusion and exclusion criteria, subjects were selected and enrolled in a randomized double-blind study to determine the effects of carbon monoxide exposure on ventricular arrhythmia frequency at rest, during exercise, and during ambulatory activities. The carbon monoxide exposure was designed to result in 3% or 5% carboxyhemoglobin levels, as measured by gas chromatography. The carbon monoxide exposure protocol produced target levels in 60 minutes, and the levels were maintained for an additional 90 minutes to provide adequate time to assess the impact of carbon monoxide on the frequency of ventricular ectopic beats. The data on total and repetitive ventricular arrhythmias were analyzed for seven specific time intervals: (1) two hours before carbon monoxide exposure; (2) during the two-hour carbon monoxide or air exposure; (3) during a two-hour rest period; (4) during an exercise period; (5) during an exercise recovery period; (6) six hours after carbon monoxide or air exposure; and (7) approximately 10 hours after exposure, or the remaining recording interval on the Holter monitor. There was no increase in ventricular arrhythmia frequency after carbon monoxide exposure, regardless of the level of carboxyhemoglobin or the type of activity.

  19. Integrated Science Assessment (ISA) for Carbon Monoxide ...

    EPA Pesticide Factsheets

    EPA announced that the First External Review Draft of the Integrated Science Assessment (ISA) for Carbon Monoxide (CO) and related Annexes was made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluation of the most policy-relevant science and will ultimately provide the scientific bases for EPA's decision regarding whether the current standards for CO sufficiently protect public health and the environment. The Integrated Plan for Review of the NAAQS for CO {U.S. EPA, 2008 #8615} identifies key policy-relevant questions that provide a framework for this review of the scientific evidence. These questions frame the entire review of the NAAQS, and thus are informed by both science and policy considerations. The ISA organizes and presents the scientific evidence such that it, when considered along with findings from risk analyses and policy considerations, will help the EPA address these questions during the NAAQS review:

  20. Reduction of Carbon Monoxide. Past Research Summary

    DOE R&D Accomplishments Database

    Schrock, R. R.

    1982-01-01

    Research programs for the year on the preparation, characterization, and reactions of binuclear tantalum complexes are described. All evidence to date suggest the following of these dimeric molecules: (1) the dimer does not break into monomers under mild conditions; (2) intermolecular hydride exchange is not negligible, but it is slow; (3) intermolecular non-ionic halide exchange is fast; (4) the ends of the dimers can rotate partially with respect to one another. The binuclear tantalum hydride complexes were found to react with carbon monoxide to give a molecule which is the only example of reduction of CO by a transition metal hydride to give a complex containing a CHO ligand. Isonitrides also reacted in a similar manner with dimeric tantalum hydride. (ATT)

  1. Carbon monoxide in the treatment of sepsis.

    PubMed

    Nakahira, Kiichi; Choi, Augustine M K

    2015-12-15

    Carbon monoxide (CO), a low-molecular-weight gas, is endogenously produced in the body as a product of heme degradation catalyzed by heme oxygenase (HO) enzymes. As the beneficial roles of HO system have been elucidated in vitro and in vivo, CO itself has also been reported as a potent cytoprotective molecule. Whereas CO represents a toxic inhalation hazard at high concentration, low-dose exogenous CO treatment (~250-500 parts per million) demonstrates protective functions including but not limited to the anti-inflammatory and antiapoptotic effects in preclinical models of human diseases. Of note, CO exposure confers protection in animal models of sepsis by inhibiting inflammatory responses and also enhancing bacterial phagocytosis in leukocytes. These unique functions of CO including both dampening inflammation and promoting host defense mechanism are mediated by multiple pathways such as autophagy induction or biosynthesis of specialized proresolving lipid mediators. We suggest that CO gas may represent a novel therapy for patients with sepsis.

  2. Carbon monoxide sensor and method of use thereof

    DOEpatents

    McDaniel; Anthony H. , Medlin; J. Will , Bastasz; Robert J.

    2007-09-04

    Carbon monoxide sensors suitable for use in hydrogen feed streams and methods of use thereof are disclosed. The sensors are palladium metal/insulator/semiconductor (Pd-MIS) sensors which may possess a gate metal layer having uniform, Type 1, or non-uniform, Type 2, film morphology. Type 1 sensors display an increased sensor response in the presence of carbon monoxide while Type 2 sensors display a decreased response to carbon monoxide. The methods and sensors disclosed herein are particularly suitable for use in proton exchange membrane fuel cells (PEMFCs).

  3. Mars in situ propellants: Carbon monoxide and oxygen ignition experiments

    NASA Technical Reports Server (NTRS)

    Linne, Diane L.; Roncace, James; Groth, Mary F.

    1990-01-01

    Carbon monoxide and oxygen were tested in a standard spark-torch igniter to identify the ignition characteristics of this potential Mars in situ propellant combination. The ignition profiles were determined as functions of mixture ratio, amount of hydrogen added to the carbon monoxide, and oxygen inlet temperature. The experiments indicated that the carbon monoxide and oxygen combination must have small amounts of hydrogen present to initiate reaction. Once the reaction was started, the combustion continued without the presence of hydrogen. A mixture ratio range was identified where ignition occurred, and this range varied with the oxygen inlet temperature.

  4. Overabundance of carbon monoxide in calorimetry tests

    SciTech Connect

    Ree, F.H.; Pitz, W.J.; Thiel, M. van; Souers, P.C.

    1996-04-04

    The amount of carbon monoxide recovered from calorimetry tests of high explosives is far larger than the amount predicted by equilibrium calculations. The present kinetics study of PETN [(nitro(oxy)methyl]-propanediol dinitrate) has revealed that the cooling of the calorimetry bomb after detonation of a PETN sample sufficiently slows those reactions that would otherwise lead to equilibrium so that these reactions are effectively frozen in the time scale of recovery of detonation products. Among these reactions, those that can create CH{sub 4} are the most important ones. Their rates are generally slow at all temperatures relevant to calorimetry tests. This and the slowing down of a reaction, CO + H{sub 2}O {yields} H{sub 2} + CO{sub 2} at temperatures below 1500 K are the main caus of the freeze-out of CO. A possible slow rate of the soot formation (i.e., condensed carbon) is not responsible for it. The sensitivity of the present result to the cooling rate of the detonation products and to free radicals is also examined. 10 refs., 5 figs., 2 tabs.

  5. Carbon monoxide poisoning in the United Arab Emirates.

    PubMed

    Al Kaabi, Juma M; Wheatley, Andrew D; Barss, Peter; Al Shamsi, Mariam; Lababidi, Anis; Mushtaq, Ahmed

    2011-01-01

    Carbon monoxide (CO) poisoning is rare in the Arabian Peninsula and occurs almost exclusively during the winter months. Knowledge and perception of the hazards of carbon monoxide is limited. Migrant workers from warm climates appear particularly at risk. We investigated 46 cases of carbon monoxide poisoning presenting at emergency departments from 2007-2009 of the two main hospitals in Al Ain city, United Arab Emirates. Interviews, hospital records, and administered questionnaires were used to collect the data. Among the 46 cases investigated, 24 (52%) were males. Foreign nationals compromised 80% of the cases and the incidence was 3.1 cases per 100,000 residents per year. Burning charcoal in poorly ventilated residences was the predominant source of the carbon monoxide poisoning. Almost all cases (98%) were admitted during the winter months, most in the early morning hours. Carboxyhaemoglobin (COHb) was significantly increased in cases with loss of consciousness and depressed consciousness. There were no reported fatalities.

  6. An interesting cause of pulmonary emboli: Acute carbon monoxide poisoning

    SciTech Connect

    Sevinc, A.; Savli, H.; Atmaca, H.

    2005-07-01

    Carbon monoxide poisoning, a public health problem of considerable significance, is a relatively frequent event today, resulting in thousands of hospitalizations annually. A 70-year-old lady was seen in the emergency department with a provisional diagnosis of carbon monoxide poisoning. The previous night, she slept in a tightly closed room heated with coal ember. She was found unconscious in the morning with poor ventilation. She had a rare presentation of popliteal vein thrombosis, pulmonary emboli, and possible tissue necrosis with carbon monoxide poisoning. Oxygen treatment with low-molecular-weight heparin (nadroparine) and warfarin therapy resulted in an improvement in both popliteal and pulmonary circulations. In conclusion, the presence of pulmonary emboli should be sought in patients with carbon monoxide poisoning.

  7. Measuring Carbon Monoxide in Auto Exhaust by Gas Chromatography.

    ERIC Educational Resources Information Center

    Jaffe, Dan; Herndon, Scott

    1995-01-01

    Presents a simple and reliable technique using commonly available equipment for monitoring carbon monoxide in automobile exhaust. The experiment utilizes a gas chromatograph and a thermal conductivity detector (TCD). (DDR)

  8. Carbon Monoxide | Air Quality Planning Unit | Ground-level ...

    EPA Pesticide Factsheets

    2017-04-10

    Carbon monoxide (CO) is a colorless, odorless gas that can increase the severity of lung ailments, cause dizziness, fatigue, nausea, and even death. EPA has defined the national ambient air quality standard (NAAQS) for carbon monoxide as nine parts per million averaged over an eight-hour period, and this threshold cannot be exceeded more than once a year or an area would be violating the standard.

  9. Catalytic carbon for oxidation of carbon monoxide in the presence of sulfur dioxide

    SciTech Connect

    Sinha, R.K.

    1980-01-22

    A carbon supported catalyst used for carbon monoxide oxidation is chemically modified by treating the activated carbon support with an oxidizing agent and/or a hydrophobic compound prior to impregnation with the catalyst mixture. The thus treated catalytic carbon is capable of oxidizing carbon monoxide in an air stream containing sulfur dioxide over an extended period of time.

  10. Review: hemodynamic response to carbon monoxide

    SciTech Connect

    Penney, D.G.

    1988-04-01

    Historically, and at present, carbon monoxide is a major gaseous poison responsible for widespread morbidity and mortality. From threshold to maximal nonlethal levels, a variety of cardiovascular changes occur, both immediately and in the long term, whose homeostatic function it is to renormalize tissue oxygen delivery. However, notwithstanding numerous studies over the past century, the literature remains equivocal regarding the hemodynamic responses in animals and humans, although CO hypoxia is clearly different in several respects from hypoxic hypoxia. Factors complicating interpretation of experimental findings include species, CO dose level and rate, route of CO delivery, duration, level of exertion, state of consciousness, and anesthetic agent used. Augmented cardiac output usually observed with moderate COHb may be compromised in more sever poisoning for the same reasons, such that regional or global ischemia result. The hypotension usually seen in most animal studies is thought to be a primary cause of CNS damage resulting from acute CO poisoning, yet the exact mechanism(s) remains unproven in both animals and humans, as does the way in which CO produces hypotension. This review briefly summarizes the literature relevant to the short- and long-term hemodynamic responses reported in animals and humans. It concludes by presenting an overview using data from a single species in which the most complete work has been done to date.

  11. Vehicle occupant exposure to carbon monoxide.

    PubMed

    Koushki, P A; al-Dhowalia, K H; Niaizi, S A

    1992-12-01

    This paper focuses on the auto commuting micro-environment and presents typical carbon monoxide (CO) concentrations to which auto commuters in central Riyadh, Saudi Arabia were exposed. Two test vehicles traveling over four main arterial roadways were monitored for inside and outside CO levels during eighty peak and off-peak hours extending over an eight-month period. The relative importance of several variables which explained the variability in CO concentrations inside autos was also assessed. It was found that during peak hours auto commuters were exposed to mean CO levels that ranged from 30 to 40 ppm over trips that typically took between 25 to 40 minutes. The mean ratio of inside to outside CO levels was 0.84. Results of variance component analyses indicated that the most important variables affecting CO concentrations inside autos were, in addition to the smoking of vehicle occupants, traffic volume, vehicle speed, period of day and wind velocity. An increase in traffic volume from 1,000 to 5,000 vehicles per hour (vph) increased mean CO level exposure by 71 percent. An increase in vehicle speed from 14 to 55 km/h reduced mean CO exposure by 36 percent. The number of traffic interruptions had a moderate effect on mean concentrations of CO inside vehicles.

  12. Integrated Science Assessment (ISA) for Carbon Monoxide ...

    EPA Pesticide Factsheets

    EPA announced that the Second External Review Draft of the Integrated Science Assessment (ISA) for Carbon Monoxide (CO) and related Annexes was made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluation of the most policy-relevant science and will ultimately provide the scientific bases for EPA's decision regarding whether the current standards for CO sufficiently protect public health and the environment. Section 108(a) of the Clean Air Act directs the EPA Administrator to identify certain pollutants that “cause or contribute to air pollution which may reasonably be anticipated to endanger public health or welfare” and to issue air quality criteria for them. These air quality criteria are to “accurately reflect the latest scientific knowledge useful in indicating the kind and extent of all identifiable effects on public health or welfare which may be expected from the presence of such pollutant in the ambient air….” Under section 109 of the Act, EPA is to establish national ambient air quality standards (NAAQS) for each pollutant for which EPA has issued criteria. Section 109(d) of the Act requires periodic review and, if appropriate, revision of existing air quality criteria to reflect advances in scientific knowledge on the effects of the pollutant on public health or welfare. EPA is also to revise the NAAQS, if appropriate, based on the revised air quality criteria.

  13. Carbon Monoxide: An Essential Signalling Molecule

    NASA Astrophysics Data System (ADS)

    Mann, Brian E.

    Carbon monoxide (CO), like nitric oxide (NO), is an essential signalling molecule in humans. It is active in the cardiovascular system as a vasodilator. In addition, CO possesses anti-inflammatory, anti-apoptotic and anti-proliferative properties and protects tissues from hypoxia and reperfusion injury. Some of its applications in animal models include suppression of organ graft rejection and safeguarding the heart during reperfusion after cardiopulmonary bypass surgery. CO also suppresses arteriosclerotic lesions following angioplasty, reverses established pulmonary hypertension and mitigates the development of post-operative ileus in the murine small intestine and the development of cerebral malaria in mice as well as graft-induced intimal hyperplasia in pigs. There have been several clinical trials using air-CO mixtures for the treatment of lung-, heart-, kidney- and abdominal-related diseases. This review examines the research involving the development of classes of compounds (with particular emphasis on metal carbonyls) that release CO, which could be used in clinically relevant conditions. The review is drawn not only from published papers in the chemical literature but also from the extensive biological literature and patents on CO-releasing molecules (CO-RMs).

  14. Effects of carbon monoxide on myocardial ischemia

    SciTech Connect

    Allred, E.N.; Pagano, M. ); Bleecker, E.R.; Walden, S.M. ); Chaitman, B.R.; Dahms, T.E. ); Hackney, J.D.; Selvester, R.H. ); Warren, J. ); Gottlieb, S.O.

    1991-02-01

    The purpose of this study was to determine whether low doses of carbon monoxide (CO) exacerbate myocardial ischemia during a progressive exercise test. The effect of CO exposure was evaluated using the objective measure of time to development of electrocardiographic changes indicative of ischemia and the subjective measure of time to onset of angina. Sixty-three male subjects (41-75 years) with well-documented coronary artery disease, who had exertional angina pectoris and ischemic ST-segment changes in their electrocardiograms, were studied. Results from three randomized, double-blind test visits (room air, low and high CO) were compared. The effect of CO exposure was determined from the percent difference in the end points obtained on exercise tests performed before and after a 1-hr exposure to room air or CO. A significant dose-response relationship was found for the individual differences in the time to ST end point and angina for the pre-versus postexposure exercise test at the three carboxyhemoglobin levels. These findings demonstrate that low doses of CO produce significant effects on cardiac function during exercise in subjects with coronary artery disease.

  15. Carbon monoxide studies at high altitude.

    PubMed

    McGrath, J J

    1988-01-01

    In high altitude areas, ambient carbon monoxide (CO) concentrations are rising because of the increasing number of new residents and tourists, and their concomitant use of motor vehicles and heating appliances. There are, however, comparatively few studies of the acute or chronic physiological effects that may be caused by inhaling CO at high altitude. There are data supporting the concept that the effects of breathing CO at high altitude are additive, and data suggesting that the effects may be more than additive. Visual sensitivity and flicker fusion frequency are reduced in humans inhaling CO at high altitude. One provocative study suggests that the increase in coronary capillarity seen with chronic altitude exposure may be blocked by CO. We exposed male, laboratory rats for 6 weeks to 100 ppm CO, 4676 m (15,000 ft) simulated high altitude (SHA), and CO at SHA. SHA increase hematocrit ratio (Hct) and right ventricle weight, but decreased body weight. CO increased Hct and left ventricle weight. Our results indicate that 100 ppm CO does not exacerbate the effects produced by exposure to 4676 m altitude.

  16. Carbon monoxide exposure in blast furnace workers.

    PubMed

    Lewis, S; Mason, C; Srna, J

    1992-09-01

    This study investigated the occupational exposure to carbon monoxide (CO) of a group of blast furnace workers from an integrated steelworks, compared to a control group having no significant occupational CO exposure from other areas in the same works. The study was undertaken in 1984 at Port Kembla, New South Wales. Carboxyhaemoglobin (COHb) levels before and after an eight-hour work shift were measured in 98 male steelworkers: 52 from two CO-exposed iron blast furnaces and 46 controls from production areas in the same steelworks. The sample was stratified by smoking habits. Environmental air CO levels had been found to be consistently higher on one furnace than on the other. Absorption of CO from the working environment occurred in workers on the blast furnace with higher CO levels, regardless of smoking habits. On this blast furnace, some readings of COHb levels after a workshift in nonsmokers approached the proposed Australian occupational limit of 5 per cent COHb saturation. Overall, workers with the highest occupational exposure who smoked most heavily had the highest absorption of CO over a work shift. Biological monitoring gives an accurate measure of individual worker 'dose' of CO from all sources. Both environmental monitoring and biological monitoring need to be included as part of a program for controlling occupational CO exposure.

  17. Carbon monoxide and anesthesia-induced neurotoxicity☆

    PubMed Central

    Levy, Richard J.

    2016-01-01

    The majority of commonly used anesthetic agents induce widespread neuronal degeneration in the developing mammalian brain. Downstream, the process appears to involve activation of the oxidative stress-associated mitochondrial apoptosis pathway. Targeting this pathway could result in prevention of anesthetic toxicity in the immature brain. Carbon monoxide (CO) is a gas that exerts biological activity in the developing brain and low dose exposures have the potential to provide neuroprotection. In recent work, low concentration CO exposures limited isoflurane-induced neuronal apoptosis in a dose-dependent manner in newborn mice and modulated oxidative stress within forebrain mitochondria. Because infants and children are routinely exposed to low levels of CO during low-flow general endotracheal anesthesia, such anti-oxidant and pro-survival cellular effects are clinically relevant. Here we provide an overview of anesthesia-related CO exposure, discuss the biological activity of low concentration CO, detail the effects of CO in the brain during development, and provide evidence for CO-mediated inhibition of anesthesia-induced neurotoxicity. PMID:27616667

  18. Effect of carbon monoxide on the cardiorespiratory system: carbon monoxide toxicity, physiology and biochemistry

    SciTech Connect

    Turino, G.M.

    1981-01-01

    Exposure to carbon monoxide compromises function of the cardiovascular system primarily by decreasing oxygen-carrying capacity in the blood and decreasing venous and tissue oxygen tension. In normal individuals, with concentrations of approximately 18 to 20% COHb, there is a reduction in the oxygen consumption during high levels of exercise, a higher than predicted cardiac output, and abnormally high concentrations of lactic acid. However, in patients with coronary artery atherosclerosis, concentrations of COHb of 3 to 5% significantly curtailed exercise tolerance before the onset of angina. In addition, there is suggestive evidence in animals that the hypoxia induced by increased levels of COHb induces atherosclerosis.

  19. The Carbon Monoxide Dehydrogenase from Desulfovibrio vulgaris.

    PubMed

    Hadj-Saïd, Jessica; Pandelia, Maria-Eirini; Léger, Christophe; Fourmond, Vincent; Dementin, Sébastien

    2015-12-01

    Ni-containing Carbon Monoxide Dehydrogenases (CODHs) catalyze the reversible conversion between CO and CO₂and are involved in energy conservation and carbon fixation. These homodimeric enzymes house two NiFeS active sites (C-clusters) and three accessory [4Fe-4S] clusters. The Desulfovibrio vulgaris (Dv) genome contains a two-gene CODH operon coding for a CODH (cooS) and a maturation protein (cooC) involved in nickel insertion in the active site. According to the literature, the question of the precise function of CooC as a chaperone folding the C-cluster in a form which accommodates free nickel or as a mere nickel donor is not resolved. Here, we report the biochemical and spectroscopic characterization of two recombinant forms of the CODH, produced in the absence and in the presence of CooC, designated CooS and CooS(C), respectively. CooS contains no nickel and cannot be activated, supporting the idea that the role of CooC is to fold the C-cluster so that it can bind nickel. As expected, CooS(C) is Ni-loaded, reversibly converts CO and CO₂, displays the typical Cred1 and Cred2 EPR signatures of the C-cluster and activates in the presence of methyl viologen and CO in an autocatalytic process. However, Ni-loaded CooS(C) reaches maximum activity only upon reductive treatment in the presence of exogenous nickel, a phenomenon that had not been observed before. Surprisingly, the enzyme displays the Cred1 and Cred2 signatures whether it has been activated or not, showing that this activation process of the Ni-loaded Dv CODH is not associated with structural changes at the active site.

  20. Encapsulation kinetics and dynamics of carbon monoxide in clathrate hydrate

    PubMed Central

    Zhu, Jinlong; Du, Shiyu; Yu, Xiaohui; Zhang, Jianzhong; Xu, Hongwu; Vogel, Sven C.; Germann, Timothy C.; Francisco, Joseph S.; Izumi, Fujio; Momma, Koichi; Kawamura, Yukihiko; Jin, Changqing; Zhao, Yusheng

    2014-01-01

    Carbon monoxide clathrate hydrate is a potentially important constituent in the solar system. In contrast to the well-established relation between the size of gaseous molecule and hydrate structure, previous work showed that carbon monoxide molecules preferentially form structure-I rather than structure-II gas hydrate. Resolving this discrepancy is fundamentally important to understanding clathrate formation, structure stabilization and the role the dipole moment/molecular polarizability plays in these processes. Here we report the synthesis of structure-II carbon monoxide hydrate under moderate high-pressure/low-temperature conditions. We demonstrate that the relative stability between structure-I and structure-II hydrates is primarily determined by kinetically controlled cage filling and associated binding energies. Within hexakaidecahedral cage, molecular dynamic simulations of density distributions reveal eight low-energy wells forming a cubic geometry in favour of the occupancy of carbon monoxide molecules, suggesting that the carbon monoxide–water and carbon monoxide–carbon monoxide interactions with adjacent cages provide a significant source of stability for the structure-II clathrate framework. PMID:24936712

  1. Pulmonary vascular stress from carbon monoxide.

    PubMed

    Thom, S R; Ohnishi, S T; Fisher, D; Xu, Y A; Ischiropoulos, H

    1999-01-01

    Studies were conducted with rats to investigate whether exposure to carbon monoxide (CO) at concentrations frequently found in the environment caused lung injury mediated by nitric oxide (*NO)-derived oxidants. Lung capillary leakage was significantly increased 18 h after rats had been exposed to CO at concentrations of 50 ppm or more for 1 h. An elevation of *NO during CO exposure was demonstrated by electron paramagnetic resonance spectroscopy. There was a 2.6-fold increase of *NO over control in the lungs of rats exposed to 100 ppm CO. A qualitative increase in the concentration of H2O2 was also detected in lungs during CO exposure, and this change was caused by *NO as it was inhibited in rats pretreated with the nitric oxide synthase inhibitor, Nomega nitro-l-arginine methyl ester (l-NAME). Production of *NO-derived oxidants during CO exposure was indicated by an elevated concentration of nitrotyrosine in lung homogenates. The CO-associated elevations in lung capillary leakage and nitrotyrosine concentration did not occur when rats were pretreated with l-NAME. CO exposure did not change the concentrations of endothelial or inducible nitric oxide synthase in lung and leukocyte sequestration was not detected as a consequence of CO exposure. CO-mediated lung leak and nitrotyrosine elevation were not affected by neutropenia. We conclude that CO exposure elevates the steady-state concentration of *NO in lungs. Consequences from this change include increases in the concentration of reactive oxygen species, production of *NO-derived oxidants such as peroxynitrite, and physiological evidence of lung injury.

  2. Pulmonary Phototherapy for Treating Carbon Monoxide Poisoning

    PubMed Central

    Zazzeron, Luca; Liu, Chen; Franco, Walfre; Nakagawa, Akito; Farinelli, William A.; Bloch, Donald B.; Anderson, R. Rox

    2015-01-01

    Rationale: Carbon monoxide (CO) exposure is a leading cause of poison-related mortality. CO binds to Hb, forming carboxyhemoglobin (COHb), and produces tissue damage. Treatment of CO poisoning requires rapid removal of CO and restoration of oxygen delivery. Visible light is known to effectively dissociate CO from Hb, with a single photon dissociating one CO molecule. Objectives: To determine whether illumination of the lungs of CO-poisoned mice causes dissociation of COHb from blood transiting the lungs, releasing CO into alveoli and thereby enhancing the rate of CO elimination. Methods: We developed a model of CO poisoning in anesthetized and mechanically ventilated mice to assess the effects of direct lung illumination (phototherapy) on the CO elimination rate. Light at wavelengths between 532 and 690 nm was tested. The effect of lung phototherapy administered during CO poisoning was also studied. To avoid a thoracotomy, we assessed the effect of lung phototherapy delivered to murine lungs via an optical fiber placed in the esophagus. Measurements and Main Results: In CO-poisoned mice, phototherapy of exposed lungs at 532, 570, 592, and 628 nm dissociated CO from Hb and doubled the CO elimination rate. Phototherapy administered during severe CO poisoning limited the blood COHb increase and improved the survival rate. Noninvasive transesophageal phototherapy delivered to murine lungs via an optical fiber increased the rate of CO elimination while avoiding a thoracotomy. Conclusions: Future development and scaling up of lung phototherapy for patients with CO exposure may provide a significant advance for treating and preventing CO poisoning. PMID:26214119

  3. Decadal Record of Satellite Carbon Monoxide Observations

    NASA Astrophysics Data System (ADS)

    Worden, Helen; Deeter, Merritt; Frankenberg, Christian; George, Maya; Nichitiu, Florian; Worden, John; Aben, Ilse; Bowman, Kevin; Clerbaux, Cathy; Coheur, Pierre-Francois; de Laat, Jos; Warner, Juying; Drummond, James; Edwards, David; Gille, John; Hurtmans, Daniel; Ming, Luo; Martinez-Alonso, Sara; Massie, Steven; Pfister, Gabriele

    2013-04-01

    Atmospheric carbon monoxide (CO) distributions are controlled by anthropogenic emissions, biomass burning, chemical production, transport and oxidation by reaction with the hydroxyl radical (OH). Quantifying trends in CO is therefore important for understanding changes related to all of these contributions. Here we present a comprehensive record of satellite observations from 2000 through 2011 of total column CO using the available measurements from nadir-viewing thermal infrared instruments: MOPITT, AIRS, TES and IASI. We examine trends for CO in the Northern and Southern hemispheres along with regional trends for E. China, E. USA, Europe and India. Measurement and sampling methods for each of the instruments are discussed, and we show diagnostics for systematic errors in MOPITT trends. We find that all the satellite observations are consistent with a modest decreasing trend around -1%/year in total column CO over the Northern hemisphere for this time period. Decreasing trends in total CO column are observed for the United States, Europe and E. China with more than 2σ significance. For India, the trend is also decreasing, but smaller in magnitude and less significant. Decreasing trends in surface CO have also been observed from measurements in the U.S. and Europe. Although less information is available for surface CO in China, there is a decreasing trend reported for Beijing. Some of the interannual variability in the observations can be explained by global fire emissions, and there may be some evidence of the global financial crisis in late 2008 to early 2009. But the overall decrease needs further study to understand the implications for changes in anthropogenic emissions.

  4. Detection of Carbon Monoxide Using Polymer-Carbon Composite Films

    NASA Technical Reports Server (NTRS)

    Homer, Margie L.; Ryan, Margaret A.; Lara, Liana M.

    2011-01-01

    A carbon monoxide (CO) sensor was developed that can be incorporated into an existing sensing array architecture. The CO sensor is a low-power chemiresistor that operates at room temperature, and the sensor fabrication techniques are compatible with ceramic substrates. Sensors made from four different polymers were tested: poly (4-vinylpryridine), ethylene-propylene-diene-terpolymer, polyepichlorohydrin, and polyethylene oxide (PEO). The carbon black used for the composite films was Black Pearls 2000, a furnace black made by the Cabot Corporation. Polymers and carbon black were used as received. In fact, only two of these sensors showed a good response to CO. The poly (4-vinylpryridine) sensor is noisy, but it does respond to the CO above 200 ppm. The polyepichlorohydrin sensor is less noisy and shows good response down to 100 ppm.

  5. The oxidation of carbon monoxide on polycrystalline rhodium under knudsen conditions. II. Reaction with nitrogen monoxide

    NASA Astrophysics Data System (ADS)

    Lintz, Hans-Günther; Weisker, Tilman

    1985-09-01

    The reaction between carbon monoxide and nitrogen monoxide on a polycrystalline rhodium ribbon under stationary conditions is followed by mass spectrometry. In the temperature range 300 to 1100 K the ratio of the partial pressures of the reactants varies between 0.1 < pNO/ pCO < 100 at values of the total pressure in the reactor from 10 -4 to 10 -5 Torr. The results can be interpreted qualitatively by a simple elementary reaction sequence. Simulation using literature values of the kinetic constants leads to semi-quantitative agreement with experimental results. No isothermal oscillations of the reaction rate could be observed under the stated conditions.

  6. The oxidation of carbon monoxide using tin oxide based catalysts

    NASA Technical Reports Server (NTRS)

    Sampson, Christopher F.; Jorgensen, Norman

    1990-01-01

    The preparation conditions for precious metal/tin oxide catalysts were optimized for maximum carbon monoxide/oxygen recombination efficiency. This was achieved by controlling the tin digestion, the peptization to form the sol, the calcination process and the method of adding the precious metals. Extensive studies of the tin oxide structure were carried out over the temperature range 20 to 500 C in air or hydrogen environments using Raman scattering and X ray diffraction. Adsorbed species on tin oxide, generated in an environment containing carbon monoxide, gave rise to a Raman band at about 1600 cm(exp -1) which was assigned to carbonaceous groups, possible carbonate.

  7. Separation of Carbon Monoxide and Carbon Dioxide for Mars ISRU

    NASA Technical Reports Server (NTRS)

    Walton, Krista S.; LeVan, M. Douglas

    2004-01-01

    The atmosphere of Mars has many resources that can be processed to produce things such as oxygen, fuel, buffer gas, and water for support of human exploration missions. Successful manipulation of these resources is crucial for safe, cost-effective, and self-sufficient long-term human exploration of Mars. In our research, we are developing enabling technologies that require fundamental knowledge of adsorptive gas storage and separation processes. In particular, we are designing and constructing an innovative, low mass, low power separation device to recover carbon dioxide and carbon monoxide for Mars ISRU (in-situ resource utilization). The technology has broad implications for gas storage and separations for gas-solid systems that are ideally suited for reduced gravitational environments. This paper describes our separation process design and experimental procedures and reports results for the separation of CO2 and CO by a four-step adsorption cycle.

  8. 40 CFR 86.222-94 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Carbon monoxide analyzer calibration. 86.222-94 Section 86.222-94 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.222-94 Carbon...

  9. 40 CFR 86.222-94 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Carbon monoxide analyzer calibration. 86.222-94 Section 86.222-94 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.222-94 Carbon...

  10. 40 CFR 86.222-94 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Carbon monoxide analyzer calibration. 86.222-94 Section 86.222-94 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.222-94 Carbon...

  11. 40 CFR 86.222-94 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Carbon monoxide analyzer calibration. 86.222-94 Section 86.222-94 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.222-94 Carbon...

  12. Effects of carbon monoxide on myocardial ischemia.

    PubMed Central

    Allred, E N; Bleecker, E R; Chaitman, B R; Dahms, T E; Gottlieb, S O; Hackney, J D; Pagano, M; Selvester, R H; Walden, S M; Warren, J

    1991-01-01

    The purpose of this study was to determine whether low doses of carbon monoxide (CO) exacerbate myocardial ischemia during a progressive exercise test. The effect of CO exposure was evaluated using the objective measure of time to development of electrocardiographic changes indicative of ischemia and the subjective measure of time to onset of angina. Sixty-three male subjects (41-75 years) with well-documented coronary artery disease, who had exertional angina pectoris and ischemic ST-segment changes in their electrocardiograms, were studied. Results from three randomized, double-blind test visits (room air, low and high CO) were compared. The effect of CO exposure was determined from the percent difference in the end points obtained on exercise tests performed before and after a 1-hr exposure to room air or CO. The exposures resulted in postexercise carboxyhemoglobin (COHb) levels of 0.6% +/- 0.3%, 2.0% +/- 0.1%, and 3.9% +/- 0.1%. The results obtained on the 2%-COHb day and 3.9%-COHb day were compared to those on the room air day. There were 5.1% (p = 0.01) and 12.1% (p less than or equal to 0.0001) decreases in the time to development of ischemic ST-segment changes after exposures producing 2.0 and 3.9% COHb, respectively, compared to the control day. In addition, there were 4.2% (p = 0.027) and 7.1% (p = 0.002) decreases in time to the onset of angina after exposures producing 2.0 and 3.9% COHb, respectively, compared to the control day. A significant dose-response relationship was found for the individual differences in the time to ST end point and angina for the pre- versus postexposure exercise tests at the three carboxyhemoglobin levels. These findings demonstrate that low doses of CO produce significant effects on cardiac function during exercise in subjects with coronary artery disease. PMID:2040254

  13. Terpolymerization of ethylene, sulfur dioxide and carbon monoxide

    DOEpatents

    Johnson, R.; Steinberg, M.

    This invention relates to high molecular weight terpolymer of ethylene, sulfur dioxide and carbon monoxide stable to 280/sup 0/C and containing as little as 36 mo1% ethylene and about 41 to 51 mo1% sulfur dioxide, and to the method of producing said terpolymer by irradiation of a liquid and gaseous mixture of ethylene, sulfur dioxide and carbon monoxide by means of Co-60 gamma rays or an electron beam, at a temperature of about 10 to 50/sup 0/C, and at a pressure of about 140 to 680 atmospheres, to initiate polymerization.

  14. Terpolymerization of ethylene, sulfur dioxide and carbon monoxide

    DOEpatents

    Johnson, Richard; Steinberg, Meyer

    1981-01-01

    This invention relates to a high molecular weight terpolymer of ethylene, sulfur dioxide and carbon monoxide stable to 280.degree. C. and containing as little as 36 mol % ethylene and about 41-51 mol % sulfur dioxide; and to the method of producing said terpolymer by irradiation of a liquid and gaseous mixture of ethylene, sulfur dioxide and carbon monoxide by means of Co-60 gamma rays or an electron beam, at a temperature of about 10.degree.-50.degree. C., and at a pressure of about 140 to 680 atmospheres, to initiate polymerization.

  15. CRISM Observations of Water Vapor and Carbon Monoxide

    NASA Technical Reports Server (NTRS)

    Smith, Michael D.; Wolff, Michael J.; Clancy, R. Todd

    2008-01-01

    Near-infrared spectra returned by the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM, [1]) on-board the Mars Reconnaissance Orbiter (MRO) contain the clear spectral signature of several atmospheric gases including carbon dioxide (CO2), water vapor (H2O), and carbon monoxide (CO). Here we describe the seasonal and spatial mapping of water vapor and carbon dioxide for one full Martian year using CRISM spectra.

  16. 40 CFR 52.1627 - Control strategy and regulations: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...: Carbon monoxide. 52.1627 Section 52.1627 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.1627 Control strategy and regulations: Carbon monoxide. (a) Part D Approval. The Albuquerque/Bernalillo County carbon monoxide maintenance plan as adopted on April 13, 1995, meets the requirements...

  17. 40 CFR 52.1627 - Control strategy and regulations: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...: Carbon monoxide. 52.1627 Section 52.1627 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.1627 Control strategy and regulations: Carbon monoxide. (a) Part D Approval. The Albuquerque/Bernalillo County carbon monoxide maintenance plan as adopted on April 13, 1995, meets the requirements...

  18. 40 CFR 52.1627 - Control strategy and regulations: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...: Carbon monoxide. 52.1627 Section 52.1627 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.1627 Control strategy and regulations: Carbon monoxide. (a) Part D Approval. The Albuquerque/Bernalillo County carbon monoxide maintenance plan as adopted on April 13, 1995, meets the requirements...

  19. 40 CFR 52.1627 - Control strategy and regulations: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...: Carbon monoxide. 52.1627 Section 52.1627 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.1627 Control strategy and regulations: Carbon monoxide. (a) Part D Approval. The Albuquerque/Bernalillo County carbon monoxide maintenance plan as adopted on April 13, 1995, meets the requirements...

  20. 40 CFR 52.1627 - Control strategy and regulations: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...: Carbon monoxide. 52.1627 Section 52.1627 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.1627 Control strategy and regulations: Carbon monoxide. (a) Part D Approval. The Albuquerque/Bernalillo County carbon monoxide maintenance plan as adopted on April 13, 1995, meets the requirements...

  1. 40 CFR Appendix A - Protocol for Using an Electrochemical Analyzer to Determine Oxygen and Carbon Monoxide...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Analyzer to Determine Oxygen and Carbon Monoxide Concentrations From Certain Engines A Appendix A...—Protocol for Using an Electrochemical Analyzer to Determine Oxygen and Carbon Monoxide Concentrations From... portable electrochemical (EC) cells for measuring carbon monoxide (CO) and oxygen (O2) concentrations...

  2. 40 CFR Appendix A - Protocol for Using an Electrochemical Analyzer to Determine Oxygen and Carbon Monoxide...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Analyzer to Determine Oxygen and Carbon Monoxide Concentrations From Certain Engines A Appendix A...—Protocol for Using an Electrochemical Analyzer to Determine Oxygen and Carbon Monoxide Concentrations From... portable electrochemical (EC) cells for measuring carbon monoxide (CO) and oxygen (O2) concentrations...

  3. 40 CFR 86.1522 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Carbon monoxide analyzer calibration...) Emission Regulations for Otto-Cycle Heavy-Duty Engines, New Methanol-Fueled Natural Gas-Fueled, and Liquefied Petroleum Gas-Fueled Diesel-Cycle Heavy-Duty Engines, New Otto-Cycle Light-Duty Trucks, and...

  4. 40 CFR 86.1522 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Carbon monoxide analyzer calibration...) Emission Regulations for Otto-Cycle Heavy-Duty Engines, New Methanol-Fueled Natural Gas-Fueled, and Liquefied Petroleum Gas-Fueled Diesel-Cycle Heavy-Duty Engines, New Otto-Cycle Light-Duty Trucks, and...

  5. 40 CFR 86.1522 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Carbon monoxide analyzer calibration...) Emission Regulations for Otto-Cycle Heavy-Duty Engines, New Methanol-Fueled Natural Gas-Fueled, and Liquefied Petroleum Gas-Fueled Diesel-Cycle Heavy-Duty Engines, New Otto-Cycle Light-Duty Trucks, and...

  6. 40 CFR 86.1522 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Carbon monoxide analyzer calibration...) Emission Regulations for Otto-Cycle Heavy-Duty Engines, New Methanol-Fueled Natural Gas-Fueled, and Liquefied Petroleum Gas-Fueled Diesel-Cycle Heavy-Duty Engines, New Otto-Cycle Light-Duty Trucks, and...

  7. 40 CFR 86.1522 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Carbon monoxide analyzer calibration... Regulations for Otto-Cycle Heavy-Duty Engines, New Methanol-Fueled Natural Gas-Fueled, and Liquefied Petroleum Gas-Fueled Diesel-Cycle Heavy-Duty Engines, New Otto-Cycle Light-Duty Trucks, and New...

  8. 40 CFR 90.317 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... carbon monoxide analyzer as described in this section. (b) Initial and periodic interference. Prior to... corrective action which may be taken.) (c) Initial and periodic calibration. Prior to its initial use and... (64 percent) is required (see following table). Example calibration points (%) Acceptable...

  9. 40 CFR 90.317 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... carbon monoxide analyzer as described in this section. (b) Initial and periodic interference. Prior to... corrective action which may be taken.) (c) Initial and periodic calibration. Prior to its initial use and... (64 percent) is required (see following table). Example calibration points (%) Acceptable...

  10. Cross Sections for Electron Collisions with Carbon Monoxide

    SciTech Connect

    Itikawa, Yukikazu

    2015-03-15

    Cross section data are collected and reviewed for electron collisions with carbon monoxide. Collision processes included are total scattering, elastic scattering, momentum transfer, excitations of rotational, vibrational and electronic states, ionization, and dissociation. For each process, recommended values of the cross sections are presented, when possible. The literature has been surveyed through to the end of 2013.

  11. Carbon monoxide detector. [electrochemical gas detector for spacecraft use

    NASA Technical Reports Server (NTRS)

    Holleck, G. L.; Bradspies, J. L.; Brummer, S. B.; Nelsen, L. L.

    1973-01-01

    A sensitive carbon monoxide detector, developed specifically for spacecraft use, is described. An instrument range of 0 to 60 ppm CO in air was devised. The fuel cell type detector is used as a highly sensitive electrolysis cell for electrochemically detecting gases. The concept of an electrochemical CO detector is discussed and the CO oxidation behavior in phosphoric and sulfuric acid electrolytes is reported.

  12. 2010 Final Assessment: Integrated Science Assessment for Carbon Monoxide

    EPA Science Inventory

    EPA released the final Integrated Science Assessment (ISA) for Carbon Monoxide (CO). This is EPA’s latest evaluation of the scientific literature on the potential human health and welfare effects associated with ambient exposures to CO. The development of this document i...

  13. CARBON MONOXIDE POISONING--A PUBLIC HEALTH PERSPECTIVE.

    EPA Science Inventory

    Carbon monoxide (CO) may be the cause of more than one-half of the fatal poisonings reported in many countries: fatal cases also are grossly under-reported or mis-diagnosed by medical professionals. Therefore, the precise number of individuals who have suffered from CO intoxicat...

  14. Photoproduction of Carbon Monoxide from Natural Organic Matter

    EPA Science Inventory

    Pioneering studies by Valentine provided early kinetic results that used carbon monoxide (CO) production to evaluate the photodecomposition of aquatic natural organic matter (NOM) . (ES&T 1993 27 409-412). Comparatively few kinetic studies have been conducted of the photodegradat...

  15. Integrated Science Assessment for Carbon Monoxide (First External Review Draft)

    EPA Science Inventory

    EPA has announced that the First External Review Draft of the Integrated Science Assessment (ISA) for Carbon Monoxide (CO) and related Annexes have been made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evalua...

  16. School Bus Carbon Monoxide Intrusion. NHTSA Technical Report.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    This report presents the findings of a voluntary program conducted over a 10-month period during which school buses were tested for carbon monoxide (CO) levels under different climatological conditions. The objective of the test program was to determine whether or not there are any serious CO intrusion problems or indications of potential problems…

  17. Carbon Monoxide Isotopes: On the Trail of Galactic Chemical Evolution

    NASA Technical Reports Server (NTRS)

    Langer, W.

    1995-01-01

    From the early days of the discovery of radio emission from carbon monoxide it was realized that it offered unusual potential for under- standing the chemical evolution of the Galaxy and external galaxies through measurements of molecular isotopes. These results bear on stellar nucleosynthesis, star formation, and gases in the interstellar medium. Progress in isotopic radio measurements will be reviewed.

  18. Some usual and unusual poisonings due to carbon monoxide.

    PubMed

    Kaye, Sidney

    2003-01-01

    Carbon monoxide poisoning is a frequent occurrence in both developed and under developed countries of the world. Carbon monoxide can be produced in fires, automobile engine exhausts and the incomplete combustion of organic matter. It is a "silent killer" that initially produces a mild progressive frontal headache, drowsiness and sleep that is usually ignored as common place. Continued low-level CO exposure for a long period of time in a confined space is cumulative and these accidental deaths are frequent but should be avoidable. Several usual and unusual poisonings are reported to illustrate its various forms of exposure. It all began many years ago when a bolt of lightening hit a fallen tree and produced a fire. Early cave man later learned to enjoy some of the benefits of this new discovery. They could now see at night, they could keep warm, keep the predators at bay, cook their food and make it taste better and be more gentle to their teeth. Also meat could be preserved and eaten at a later date especially if it were dried and smoked. They learned by trial and error that it was dangerous to bring their fire deep into their cave without a chimney. Carbon monoxide (CO) also can be easily produced by many other sources besides fire. Very common today is the incomplete combustion of gasoline in the engine of an automobile which can produce about 6% carbon monoxide.

  19. AIR QUALITY CRITERIA CARBON MONOXIDE, EXTERNAL REVIEW DRAFT

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA) promulgates the National Ambient Air Quality Standards (NAAQS) on the basis of scientific information contained in criteria documents. The last air quality criteria document for carbon monoxide (CO) was completed by EPA in 1991. This...

  20. Effect of carbon monoxide on Swiss albino mice

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Cumming, H. J.

    1977-01-01

    Times to incapacitation and death and LC50 values were determined for male Swiss albino mice exposed to different concentrations of carbon monoxide in a 4.2 liter hemispherical chamber. These values are compared to values reported in the literature. The LC50 for a 30 minute exposure was 3570 ppm CO.

  1. Carbon Monoxide Poisoning - Multiple Languages: MedlinePlus

    MedlinePlus

    ... on this page, please enable JavaScript. Amharic (amarunya) Arabic (العربية) Chinese - Traditional (繁體中文) French (français) German (Deutsch) ... Amharic) PDF Centers for Disease Control and Prevention Arabic (العربية) Carbon Monoxide Poisoning English (Arabic) العربية PDF ...

  2. Integrated Science Assessment for Carbon Monoxide (Second External Review Draft)

    EPA Science Inventory

    EPA has announced that the Second External Review Draft of the Integrated Science Assessment (ISA) for Carbon Monoxide (CO) and related Annexes have been made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evalu...

  3. 2010 Final Assessment: Integrated Science Assessment for Carbon Monoxide

    EPA Science Inventory

    Cover of the Integrated Science Assessment (ISA) for <span class=Carbon Monoxide" vspace = "5" hspace="5" align="right" border="1" /> EPA has released the final Integrated Science Assessment (ISA) for ...

  4. 40 CFR 86.1322-84 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate... be used. (2) Zero the carbon monoxide analyzer with either zero-grade air or zero-grade nitrogen. (3... either zero-grade air or zero-grade nitrogen. (3) Calibrate on each used operating range with a...

  5. 40 CFR 86.1322-84 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate... be used. (2) Zero the carbon monoxide analyzer with either zero-grade air or zero-grade nitrogen. (3... either zero-grade air or zero-grade nitrogen. (3) Calibrate on each used operating range with a...

  6. 40 CFR 86.1322-84 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate... be used. (2) Zero the carbon monoxide analyzer with either zero-grade air or zero-grade nitrogen. (3... either zero-grade air or zero-grade nitrogen. (3) Calibrate on each used operating range with a...

  7. Carbon monoxide metabolism by the photosynthetic bacterium Rhodospirillum rubrum

    SciTech Connect

    Ludden, P.W.; Roberts, G.P.

    1991-01-01

    Research continued on carbon monoxide metabolism by Rhodospirillum rubrum. In the past year, progress was made in: (1) the identification and isolation of the physiological electron carrier from monoxide dehydrogenase (CODH) to hydrogenase in R. rubrum; (2) the isolation, sequencing and mutagenesis of the genes encoding the components of the CO oxidation system in R. rubrum, (3) the purification and characterization of the CO-induced hydrogenase activity of R. rubrum; (4) the spectroscopic investigation of the cobalt-substituted form of the enzyme.

  8. Carbon monoxide poisoning during natural disasters: the Hurricane Rita experience.

    PubMed

    Cukor, Jeffrey; Restuccia, Marc

    2007-10-01

    We report the incidence and mechanisms of carbon monoxide exposure during the first 5 days after Hurricane Rita, as experienced by a Disaster Medical Assistance Team staffing the only open health care facility in the Beaumont, Texas region after the storm. Improper placement of portable generators in indoor locations or proximate to home air conditioning intake systems were completely responsible for the 21 exposures including 5 fatalities, 1 brain dead, 2 transfers for hospitalization, and 13 treated and released. We discuss the clinical presentations and treatment approaches, provide a brief overview of carbon monoxide and offer novel preventive recommendations. Portable generator use after disasters represents a predictable risk to the public. Proper ventilation requirements for generators are not adequately appreciated and engineered safeties should be explored to mitigate illness.

  9. Catalysis of carbon monoxide methanation by deep sea manganate minerals

    NASA Technical Reports Server (NTRS)

    Cabrera, A. L.; Maple, M. B.; Arrhenius, G.

    1990-01-01

    The catalytic activity of deep sea manganese nodule minerals for the methanation of carbon monoxide was measured with a microcatalytic technique between 200 and 460 degrees C. The manganate minerals were activated at 248 degrees C by immersion into a stream of hydrogen in which pulses of carbon monoxide were injected. Activation energies for the methanation reaction and hydrogen desorption from the manganate minerals were obtained and compared with those of pure nickel. Similar energy values indicate that the activity of the nodule materials for the reaction appears to be related to the amount of reducible transition metals present in the samples (ca. 11 wt.-%). Since the activity of the nodule minerals per gram is comparable to that of pure nickel, most of the transition metal ions located between manganese oxide layers appear to be exposed and available to catalyze the reaction.

  10. Composite catalyst for carbon monoxide and hydrocarbon oxidation

    DOEpatents

    Liu, W.; Flytzani-Stephanopoulos, M.

    1996-03-19

    A method and composition are disclosed for the complete oxidation of carbon monoxide and/or hydrocarbon compounds. The method involves reacting the carbon monoxide and/or hydrocarbons with an oxidizing agent in the presence of a metal oxide composite catalyst. The catalyst is prepared by combining fluorite-type oxygen ion conductors with active transition metals. The fluorite oxide, selected from the group consisting of cerium oxide, zirconium oxide, thorium oxide, hafnium oxide, and uranium oxide, and may be doped by alkaline earth and rare earth oxides. The transition metals, selected from the group consisting of molybdenum, copper, cobalt, manganese, nickel, and silver, are used as additives. The atomic ratio of transition metal to fluorite oxide is less than one.

  11. Composite catalyst for carbon monoxide and hydrocarbon oxidation

    DOEpatents

    Liu, Wei; Flytzani-Stephanopoulos, Maria

    1996-01-01

    A method and composition for the complete oxidation of carbon monoxide and/or hydrocarbon compounds. The method involves reacting the carbon monoxide and/or hydrocarbons with an oxidizing agent in the presence of a metal oxide composite catalyst. The catalyst is prepared by combining fluorite-type oxygen ion conductors with active transition metals. The fluorite oxide, selected from the group consisting of cerium oxide, zirconium oxide, thorium oxide, hafnium oxide, and uranium oxide, and may be doped by alkaline earth and rare earth oxides. The transition metals, selected from the group consisting of molybdnum, copper, cobalt, maganese, nickel, and silver, are used as additives. The atomic ratio of transition metal to fluorite oxide is less than one.

  12. Retrograde amnesia following carbon monoxide poisoning: a case report.

    PubMed

    Acland, Peter R; Heaver, Catriona

    2008-07-01

    Retrograde amnesia is a recognised neurological complication of carbon monoxide poisoning. This article describes the case of a female found dead in her bath where initial post-mortem findings and the surrounding circumstances raised strong suspicions of homicide, especially when there was contradictory evidence from her husband who was the only other person present. He was later diagnosed as having retrograde amnesia between his two visits to the bathroom to attend to his wife which caused him to merge them into one event, thus arousing suspicions of foul play. The discussion explores the current clinical views on non-fatal carbon monoxide poisoning as well as problems of interpretation of information derived from case work.

  13. Catalyst for the methanation of carbon monoxide in sour gas

    DOEpatents

    Kustes, William A.; Hausberger, Arthur L.

    1985-01-01

    The invention involves the synergistic effect of the specific catalytic constituents on a specific series of carriers for the methanation of carbon monoxide in the presence of sulfur at relatively high temperatures and at low steam to gas ratios in the range of 0.2:1 or less. This effect was obtained with catalysts comprising the mixed sulfides and oxides of nickel and chromium supported on carriers comprising magnesium aluminate and magnesium silicate. Conversion of carbon monoxide to methane was in the range of from 40 to 80%. Tests of this combination of metal oxides and sulfides on other carriers and tests of other metal oxides and sulfides on the same carrier produced a much lower level of conversion.

  14. Ab initio simulations of liquid carbon monoxide at high pressure

    NASA Astrophysics Data System (ADS)

    Leonhardi, Tanis C.; Militzer, Burkhard

    2017-03-01

    Carbon monoxide occurs as a volatile species in the interiors of terrestrial planets, and as a disequilibrium atmospheric constituent in the giant planets. It plays an important role during the accretionary stages of planet formation reacting with gases to form compounds such as CH4 and H2O. The structure of carbon monoxide is unknown over the majority of the temperature and pressure regime in giant planet interiors. Here we perform ab initio molecular dynamics simulations to characterize CO to 140 GPa and 5,000 K. We find that CO is stable as a molecular liquid at lower P-T conditions, as a polymeric liquid at higher P-T conditions found in ice giant interiors, and as a plasma at high-T.

  15. Exergy parametric study of carbon monoxide oxidation in moist air

    NASA Astrophysics Data System (ADS)

    Souidi, Ferhat; Benmalek, Toufik; Yesaad, Billel; Baik, Mouloud

    2015-12-01

    This study aims to analyze the oxidation of carbon monoxide in moist air from the second thermodynamic law aspect. A mathematical model of laminar premixed flame in a stagnation point flow has been achieved by numerical solution of the boundary layer equation using a self-made code. The chemical kinetic mechanism for flameless combustion of fuel, which is a mixture of carbon monoxide, oxygen, and water vapor, is modeled by 34 elementary reactions that incorporate (09) nine chemical species: CO, O, CO2, O2, H2O, H, H2, HO2, and OH. The salient point is that for all the parameters we considered, the exergy of the process is completely destroyed by irreversibilities. From the chemical viewpoint, the OH radical plays an essential role in CO oxidation. This latter point has already been mentioned by previous investigators.

  16. Effect of carbon monoxide and nitrogen dioxide on ICR mice

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Cumming, H. J.

    1977-01-01

    Times to incapacitation and death and LC(50) values were determined for male ICR mice exposed to different concentration of carbon monoxide for 30 min and of nitrogen dioxide for 10 min in a 4.2 liter hemispherical chamber. The data indicate that ICR mice are more resistant to these two toxicants than Swiss albino mice. The carbon monoxide LC(50) for a 30-min exposure was about 8,000 ppm for ICR mice compared to 3,570 ppm for Swiss albino mice. The nitrogen dioxide LC(50) for a 10-min exposure was above 2,000 ppm for ICR mice compared to about 1,000 ppm for Swiss albino mice.

  17. Diffusing capacity and anatomic dead space for carbon-18 monoxide.

    NASA Technical Reports Server (NTRS)

    Wagner, P. D.; Mazzone, R. W.; West, J. B.

    1971-01-01

    Carbon monoxide (CO) is difficult to measure with a respiratory mass spectrometer because of the similar mass numbers of CO and nitrogen, but this is possible using carbon-18 monoxide. The mass resolution, signal-to-noise ratio, linearity, and background were all found to be adequate. The measurement of the single-breath diffusing capacity was examined. Unless the mean alveolar volume during breath holding is used in the calculation, the value for Dco obtained depends on which portion of the alveolar sample is analyzed. The anatomic dead space for CO was found to be almost the same as that for argon suggesting that the diffusion rate at the dead space-alveolar gas interface was not greatly affected by the alveolar concentration of the gas.

  18. Mechanistical studies on the formation of carbon dioxide in extraterrestrial carbon monoxide ice analog samples.

    PubMed

    Bennett, Chris J; Jamieson, Corey S; Kaiser, Ralf I

    2009-06-07

    Binary ice mixtures of two carbon monoxide isotopomers, (13)C(16)O and (12)C(18)O, were subjected at 10 K to energetic electrons to investigate the interaction of ionizing radiation with extraterrestrial, carbon monoxide bearing ices. The chemical modifications were monitored on line and in situ via absorption-reflection-absorption Fourier transform infrared spectroscopy as well as in the gas-phase via a quadrupole mass spectrometer. Detected products include two newly formed carbon monoxide isotopomers ((12)C(16)O and (13)C(18)O), carbon dioxide ((12)C(16)O(2), (12)C(18)O(16)O, (12)C(18)O(2), (13)C(16)O(2), (13)C(18)O(16)O, and (13)C(18)O(2)), and dicarbon monoxide ((12)C(13)C(16)O and (13)C(13)C(16)O). Kinetic profiles of carbon monoxide and of carbon dioxide were extracted and fit to derive reaction mechanisms and information on the decomposition of carbon monoxide and on the formation of carbon dioxide in extraterrestrial ice analog samples.

  19. Carbon Monoxide Poisoning: Death on Mount McKinley,

    DTIC Science & Technology

    1987-05-08

    asphyxiation due to acute carbon monoxide poisoning. Their blood carboxyhemoglobin concentrations were measured at 56.9% and 65.6%, respectively...and chronic exposure to CO. Thus, in the presence of carboxyhemoglobin (COHb)q the tissue partial pressure of oxygen may be lower than in the case of a...Halebian, et al found no significant difference in measured 02 consumption or extraction between dogs subjected to CO poisoning vs nitrogen anoxia.(9

  20. Guideline for modeling carbon monoxide from roadway intersections

    SciTech Connect

    DiCristofaro, D.C.

    1992-11-01

    The guideline is designed to evaluate air quality impacts at one or more roadway intersections where vehicular traffic will cause or contribute to increased emissions of carbon monoxide (CO). The explicit purpose of the guideline is to provide a consistent, scientifically acceptable method for estimating the air quality impacts of vehicular traffic at intersections to determine if such impacts may exceed the National Ambient Air Quality Standards (NAAQS) for CO.

  1. [Sudden unilateral sensorineural hearing loss after carbon monoxide intoxication].

    PubMed

    Michalska-Piechowiak, Teresa; Miarzyńska, Maria; Perlik-Gattner, Irena

    2004-01-01

    A case of unilateral sensorineural hearing loss of the left ear after carbon monoxide intoxication was presented. The diagnosis was based upon an interview, medical examinations and audiometric investigations. Results of diagnostic evaluations, clinical presentation and treatment were discussed. Hearing improvement was obtained after 6 days of treatment and normal hearing returned after 14 days. Patients who suffer from CO intoxication are at risk of hearing impairment, therefore, there is a need for audiometric follow up in these patients.

  2. Carbon monoxide fractions in cigarette and hookah (hubble bubble) smoke.

    PubMed

    Sajid, K M; Akhter, M; Malik, G Q

    1993-09-01

    We studied the carbon monoxide (CO) fractions in hookah and cigarette smoke, using a carbon monoxide micro smokerlyzer (model EC50, BEDFONT, U.K.). Mean carbon monoxide fractions (% by volume) of hookah smoke, using domestic charcoal were 0.38 +/- 0.07 (large hookah; unfiltered); 1.40 +/- 0.43 (small hookah; unfiltered); 0.34 +/- 0.06 (large hookah; filtered); 1.36 +/- 0.35 (small hookah; filtered) and 0.41 +/- 0.08 (cigarette smoke). The highest fractions were obtained with small size hookah and increase in size of hookah (i.e., volume of air in water base, fire bowl volume, pipe length, etc.) reduced the CO fraction significantly (P < 0.001). The fractions of cigarette lie between large and small hookah. The fractions vary slightly with different varieties of tobacco, e.g., CO fractions with Dera wala tobacco are significantly low (P < 0.05). Use of commercial charcoal gives significant rise in CO fractions (P < 0.001). Comparison of filtered and unfiltered smoke shows no significant difference in values. We conclude that the CO hazard is as high with hookah smoking as with cigarette smoking.

  3. Molecular dynamics simulation of photodissociation of carbon monoxide from hemoglobin

    SciTech Connect

    Henry, E.R.; Levitt, M.; Eaton, W.A.

    1985-04-01

    A molecular dynamics simulation of the photodissociation of carbon monoxide from the alpha subunit of hemoglobin is described. To initiate photodissociation, trajectories of the liganded molecule were interrupted, the iron-carbon monoxide bond was broken, and the parameters of the iron-nitrogen bonds were simultaneously altered to produce a deoxyheme conformation. Heme potential functions were used that reproduce the energies and forces for the iron out-of-plane motion obtained from quantum mechanical calculations. The effect of the protein on the rate and extent of the displacement of the iron from the porphyrin plane was assessed by comparing the results with those obtained for an isolated complex of heme with imidazole and carbon monoxide. The half-time for the displacement of the iron from the porphyrin plane was found to be 50-150 fs for both the protein and the isolated complex. These results support the interpretation of optical absorption studies using 250-fs laser pulses that the iron is displaced from the porphyrin plane within 350 fs in both hemoglobin and a free heme complex in solution.

  4. Carbon monoxide sensors. January 1970-April 1989 (Citations from the COMPENDEX data base). Report for January 1970-April 1989

    SciTech Connect

    Not Available

    1989-04-01

    This bibliography contains citations concerning the measurement and sensing of carbon monoxide. Carbon monoxide sensors used to prevent asphyxiation, combustion, and explosion are discussed. Carbon monoxide sensors used to measure combustion efficiency and gas levels in the atmosphere are included. Designs for gas sensors that measure several gases or carbon monoxide alone are presented. Extraterrestrial applications of carbon monoxide sensors are excluded. (Contains 140 citations fully indexed and including a title list.)

  5. Mobile Carbon Monoxide Monitoring System Based on Arduino-Matlab for Environmental Monitoring Application

    NASA Astrophysics Data System (ADS)

    Azieda Mohd Bakri, Nur; Junid, Syed Abdul Mutalib Al; Razak, Abdul Hadi Abdul; Idros, Mohd Faizul Md; Karimi Halim, Abdul

    2015-11-01

    Nowadays, the increasing level of carbon monoxide globally has become a serious environmental issue which has been highlighted in most of the country globally. The monitoring of carbon monoxide content is one of the approaches to identify the level of carbon monoxide pollution towards providing the solution for control the level of carbon monoxide produced. Thus, this paper proposed a mobile carbon monoxide monitoring system for measuring the carbon monoxide content based on Arduino-Matlab General User Interface (GUI). The objective of this project is to design, develop and implement the real-time mobile carbon monoxide sensor system and interfacing for measuring the level of carbon monoxide contamination in real environment. Four phases or stages of work have been carried out for the accomplishment of the project, which classified as sensor development, controlling and integrating sensor, data collection and data analysis. As a result, a complete design and developed system has been verified with the handheld industrial standard carbon monoxide sensor for calibrating the sensor sensitivity and measurement in the laboratory. Moreover, the system has been tested in real environments by measuring the level of carbon monoxide in three different lands used location; industrial area; residential area and main road (commercial area). In this real environment test, the industrial area recorded the highest reading with 71.23 ppm and 82.59 ppm for sensor 1 and sensor 2 respectively. As a conclusion, the mobile realtime carbon monoxide system based on the Arduino-Matlab is the best approach to measure the carbon monoxide concentration in different land-used since it does not require a manual data collection and reduce the complexity of the existing carbon monoxide level concentration measurement practise at the same time with a complete data analysis facilities.

  6. Magnesium carbonate precipitate strengthened aerobic granules.

    PubMed

    Lee, Duu-Jong; Chen, Yu-You

    2015-05-01

    Aerobic granules were precipitated internally with magnesium carbonate to enhance their structural stability under shear. The strengthened granules were tested in continuous-flow reactors for 220 days at organic loadings of 6-39 kg/m(3)/day, hydraulic retention times of 0.44-19 h, and temperatures of 10 or 28°C. The carbonate salt had markedly improved the granule strength without significant changes in granule morphology or microbial communities (with persistent strains Streptomyces sp., Rhizobium sp., Brevundimonas sp., and Nitratireductor sp.), or sacrifice in biological activity for organic degradation. MgCO3 precipitated granules could be used in continuous-flow reactor for wastewater treatment at low cost and with easy processing efforts.

  7. Carbon monoxide poisoning - Immediate diagnosis and treatment are crucial to avoid complications.

    SciTech Connect

    Rosenthal, L.D.

    2006-03-15

    Carbon monoxide is an odorless, colorless, tasteless gas produced by the incomplete combustion of carbon-containing fuels (oil, kerosene, coal, wood) or the inadequate ventilation of natural gas. When carbon monoxide is introduced into the bloodstream, it binds to hemoglobin, reducing the number of binding sites available for oxygen. Carbon monoxide also changes the structure of the hemoglobin molecule, which makes it even more difficult for oxygen that has attached to be released into tissues. The resulting tissue ischemia can lead to organ failure, permanent changes in cognition, or death. Carbon monoxide poisoning is the leading cause of death by poisoning in industrialized countries.

  8. Experimental evaluation of the ignition process of carbon monoxide and oxygen in a rocket engine

    NASA Technical Reports Server (NTRS)

    Linne, Diane L.

    1996-01-01

    Carbon monoxide and oxygen ignition boundaries were determined in a spark torch igniter as a function of propellant inlet temperatures. The oxygen temperature was varied from ambient to -258 F, and the carbon monoxide temperature was varied from ambient to -241 F. With the oxygen and carbon monoxide at -253 F and -219 F, respectively, they successfully ignited between mixture ratios of 2.42 and 3.10. Analysis of the results indicated that the lower ignition boundary was more sensitive to oxygen temperature than to carbon monoxide temperature. Another series of tests was performed in a small simulated rocket engine with oxygen at -197 F and carbon monoxide at -193 F. An oxygen/hydrogen flame was used to initiate combustion of the oxygen and carbon monoxide. Tests performed at the optimum operating mixture ratio of 0.55 obtained steady-state combustion in every test.

  9. Gas geyser--a cause of fatal domestic carbon monoxide poisoning.

    PubMed

    Mohankumar, T S; Kanchan, Tanuj; Pinakini, K S; Menezes, Ritesh G; Singh, Manisha; Sirohi, Parmendra; Anwar, Naureen

    2012-11-01

    Carbon monoxide is responsible for a large number of accidental domestic poisoning and deaths throughout the world. Domestic carbon monoxide poisoning is rarely reported in India and remains an under recognized problem. The diagnosis of carbon monoxide poisoning is usually based on autopsy findings, circumstantial evidence and estimation of carboxy-haemoglobin in blood. We report a case of fatal accidental carbon monoxide poisoning in a bathroom where an LPG gas water heater was installed recently. Cherry pink discolouration of the body and organs on autopsy suggested carbon monoxide poisoning. Laboratory analysis of blood by UV visible spectrophotometry revealed presence of dangerous levels of carboxy-haemoglobin. Effective preventive measures can help in bringing down the mortality and morbidity associated with carbon monoxide poisoning.

  10. Cardiovascular effects of chronic carbon monoxide and high-altitude exposure

    SciTech Connect

    McGrath, J.J. )

    1989-07-01

    At higher altitudes, ambient carbon monoxide levels are increasing with the number of residents and tourists and their use of motor vehicles and heating devices (such as fireplaces, furnaces, and stoves). Although chronic exposure to carbon monoxide or high altitude causes pronounced cardiovascular changes in humans as well as in animals, there is little information on the effects elicited by these stressors combined. Data from acute studies and theoretical considerations suggest that carbon monoxide inhaled at altitude may be more detrimental than carbon monoxide inhaled at sea level. It is not known, however, if the cardiovascular system adapts or deteriorates with continuous, concurrent exposure to carbon monoxide and high altitude. Male laboratory rats were exposed for six weeks in steel barometric chambers to altitudes ranging from 3,300 ft (ambient) to 18,000 ft and to concentrations ranging from 0 to 500 parts per million (ppm)2. Carbon monoxide had no effect on body weight at any altitude. There was a tendency for hematocrit to increase even at the lowest concentration of carbon monoxide (9 ppm), but the increase did not become significant until 100 ppm. At 10,000 ft, there was a tendency for total heart weight to increase in rats inhaling 100 ppm carbon monoxide. Although its effects on the heart at altitude are complex, carbon monoxide, in concentrations of 500 ppm or less, had little effect on the right ventricle; it did not exacerbate any effects due to altitude. There was a tendency for the left ventricle weight to increase with exposure to 35 ppm carbon monoxide at altitude, but the increase was not significant until 100 ppm carbon monoxide. Heart rate, blood pressure, cardiac output, and peripheral resistance were unaffected by exposure to 35 ppm carbon monoxide or 10,000-ft altitude singly or in combination.

  11. Carbon Monoxide Affecting Planetary Atmospheric Chemistry

    NASA Astrophysics Data System (ADS)

    He, Chao; Horst, Sarah

    2016-10-01

    Atmospheric hazes are present in a range of solar system and extrasolar planetary atmospheres, and organic hazes, such as that in Titan's atmosphere, could be a source of prebiotic molecules.1 However, the chemistry occurring in planetary atmospheres and the resulting chemical structures are still not clear. Numerous experimental simulations2 have been carried out in the laboratory to understand the chemistry in N2/CH4 atmospheres, but very few simulations4 have included CO in their initial gas mixtures, which is an important component in many N2/CH4 atmospheres including Titan, Triton, and Pluto.3 Here we have conducted a series of atmosphere simulation experiments using AC glow discharge (cold plasma) as energy source to irradiate reactions in gas mixtures of CO, CH4, and N2 with a range of CO mixing ratios (from 0, 0.05%, 0.2%, 0.5%, 1%, 2.5%, to 5%) at low temperature (~100 K). Gas phase products are monitored during the reaction by quadrupole mass spectrometer (MS), and solid phase products are analyzed by solution-state nuclear magnetic resonance spectroscopy (NMR). MS results show that with the increase of CO in the initial gases, the production of nitrogenous organic molecules increases while the production of hydrogen molecules decreases in the gas phase. NMR measurements of the solid phase products show that with the increase of CO, hydrogen atoms bonded to nitrogen or oxygen in unsaturated structures increase while those bonded to saturated carbon decrease, which means more unsaturated species and less saturated species formed with the addition of CO. MS and NMR results demonstrate that the inclusion of CO affects the compositions of both gas and solid phase products, indicating that CO has an important impact on the chemistry occurring in our experiments and probably in planetary atmospheres.1. Hörst, S. M., et al. 2012, AsBio, 12, 8092. Cable, M. L., et al. 2012, Chem. Rev., 112, 18823. Lutz, B. L., et al. 1983, Sci, 220, 1374; Greaves, J. S., et al

  12. Ambient carbon monoxide and the risk of hospitalization due to chronic obstructive pulmonary disease.

    PubMed

    Tian, Linwei; Ho, Kin-fai; Wang, Tong; Qiu, Hong; Pun, Vivian C; Chan, Chi Sing; Louie, Peter K K; Yu, Ignatius T S

    2014-12-15

    Data from recent experimental and clinical studies have indicated that lower concentrations of inhaled carbon monoxide might have beneficial antiinflammatory effects. Inhaled carbon monoxide has the potential to be a therapeutic agent for chronic obstructive pulmonary diseases (COPD). However, population-based epidemiologic studies of environmentally relevant carbon monoxide exposure have generated mixed findings. We conducted a time-series study in Hong Kong to estimate the association of short-term exposure to ambient carbon monoxide with emergency hospitalizations for COPD. We collected daily emergency hospital admission data and air pollution data from January 2001 to December 2007. We used log-linear Poisson models to estimate the associations between daily hospital admissions for COPD and the average daily concentrations of carbon monoxide while controlling for the traffic-related co-pollutants nitrogen dioxide and particulate matter with an aerodynamic diameter less than 2.5 μm. Results showed that ambient carbon monoxide was negatively associated with the risk of hospitalizations for COPD. After adjustment for levels nitrogen dioxide or particulate matter with an aerodynamic diameter less than 2.5 μm, the negative associations of carbon monoxide with COPD hospitalizations became stronger. The risk estimates were similar for female and male subjects. In conclusion, short-term exposure to ambient carbon monoxide was associated with a decreased risk of hospitalization for COPD, which suggests that carbon monoxide exposure provides some acute protection of against exacerbation of COPD.

  13. 40 CFR 52.1164 - Localized high concentrations-carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Localized high concentrations-carbon... Localized high concentrations—carbon monoxide. (a) Not later than October 1, 1975, the Commonwealth shall... quality standards for carbon monoxide. Once such localized areas have been identified, the...

  14. 78 FR 48638 - Approval and Promulgation of State Implementation Plans: Alaska; Fairbanks Carbon Monoxide...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-09

    ... AGENCY 40 CFR Part 52 Approval and Promulgation of State Implementation Plans: Alaska; Fairbanks Carbon.... SUMMARY: The EPA is proposing to approve a carbon monoxide Limited Maintenance Plan for the Fairbanks Area... demonstrates that the Fairbanks Area will maintain the carbon monoxide National Ambient Air Quality...

  15. 40 CFR 52.1164 - Localized high concentrations-carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Localized high concentrations-carbon... Localized high concentrations—carbon monoxide. (a) Not later than October 1, 1975, the Commonwealth shall... quality standards for carbon monoxide. Once such localized areas have been identified, the...

  16. 40 CFR 52.1164 - Localized high concentrations-carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Localized high concentrations-carbon... Localized high concentrations—carbon monoxide. (a) Not later than October 1, 1975, the Commonwealth shall... quality standards for carbon monoxide. Once such localized areas have been identified, the...

  17. 40 CFR 52.1164 - Localized high concentrations-carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Localized high concentrations-carbon... Localized high concentrations—carbon monoxide. (a) Not later than October 1, 1975, the Commonwealth shall... quality standards for carbon monoxide. Once such localized areas have been identified, the...

  18. 40 CFR 52.1164 - Localized high concentrations-carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Localized high concentrations-carbon... Localized high concentrations—carbon monoxide. (a) Not later than October 1, 1975, the Commonwealth shall... quality standards for carbon monoxide. Once such localized areas have been identified, the...

  19. Mixing ratios of carbon monoxide in the troposphere

    SciTech Connect

    Novelli, P.C.; Steele, L.P. ); Tans, P.P. )

    1992-12-20

    Carbon monoxide (CO) mixing ratios were measured in air samples collected weekly at eight locations. The air was collected as part of the CMDL/NOAA cooperative flask sampling program (Climate Monitoring and Diagnostics Laboratory, formerly Geophysical Monitoring for Climatic Change, Air Resources Laboratory/National Oceanic and Atmospheric Administration) at Point Barrow, Alaska, Niwot Ridge, Colorado, Mauna Loa and Cape Kumakahi, Hawaii, Guam, Marianas Islands, Christmas Island, Ascension Island and American Samoa. Half-liter or 3-L glass flasks fitted with glass piston stopcocks holding teflon O rings were used for sample collection. CO levels were determined within several weeks of collection using gas chromatography followed by mercuric oxide reduction detection, and mixing ratios were referenced against the CMDL/NOAA carbon monoxide standard scale. During the period of study (mid-1988 through December 1990) CO levels were greatest in the high latitudes of the northern hemisphere (mean mixing ratio from January 1989 to December 1990 at Point Barrow was approximately 154 ppb) and decreased towards the south (mean mixing ratio at Samoa over a similar period was 65 ppb). Mixing ratios varied seasonally, the amplitude of the seasonal cycle was greatest in the north and decreased to the south. Carbon monoxide levels were affected by both local and regional scale processes. The difference in CO levels between northern and southern latitudes also varied seasonally. The greatest difference in CO mixing ratios between Barrow and Samoa was observed during the northern winter (about 150 ppb). The smallest difference, 40 ppb, occurred during the austral winter. The annually averaged CO difference between 71[degrees]N and 14[degrees]S was approximately 90 ppb in both 1989 and 1990; the annually averaged interhemispheric gradient from 71[degrees]N to 41[degrees]S is estimated as approximately 95 ppb. 66 refs., 5 figs., 5 tabs.

  20. Pathways and Bioenergetics of Anaerobic Carbon Monoxide Fermentation

    PubMed Central

    Diender, Martijn; Stams, Alfons J. M.; Sousa, Diana Z.

    2015-01-01

    Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the potential of converting CO-rich gas, such as synthesis gas, into bio-based products. Three main types of fermentative CO metabolism can be distinguished: hydrogenogenesis, methanogenesis, and acetogenesis, generating hydrogen, methane and acetate, respectively. Here, we review the current knowledge on these three variants of microbial CO metabolism with an emphasis on the potential enzymatic routes and bio-energetics involved. PMID:26635746

  1. Transient PrOx carbon monoxide measurement, control, and optimization

    SciTech Connect

    Inbody, M. A.; Borup, R. L.; Tafoya, J.

    2002-01-01

    Fuel processing systems for low temperature polymer electrolyte membrane (PEM) fuel cell systems require control of the carbon monoxide concentration to less than 100 ppm to 10 ppm in the anode feed. Conventional hydrocarbon fuel processors use a water-gas shift (WGS) reactor to react CO with water to form H2 and reduce the CO concentration. The CO conversion is limited by equilibrium at the outlet temperature of the WGS reactor. The WGS outlet CO concentration can range from over 1% to 2000 ppm depending on the system and its operating parameters. At these concentrations, CO poisons low temperature PEM fuel cells and the concentrations needs to be reduced further.

  2. Compact carbon monoxide sensor utilizing a confocal optical cavity.

    NASA Technical Reports Server (NTRS)

    Scott, B.; Magyar, J.; Weyant, R.; Hall, J.

    1973-01-01

    The carbon monoxide sensor discussed in this paper utilizes a unique confocal cavity which allows the complete system to be packaged in a small volume suitable for hand-held use. The optical system is the heart of the instrument with equal emphasis placed on the electronics support circuitry, consisting essentially of a thermal infrared pyroelectric detector and lock-in amplifier. The pyroelectric detector offers a major advantage over other thermal detectors, providing a signal-to-noise ratio and detectivity that remain nearly constant over the frequency range from dc to 2000 Hz. Since bias voltage is not required, low frequency noise is not generated in the detector.

  3. Comparison between carbon monoxide measurements from spaceborne and airborne platforms

    NASA Technical Reports Server (NTRS)

    Connors, V. S.; Cahoon, D. R.; Reichle, H. G., Jr.; Scheel, H. E.

    1991-01-01

    The measurements of air pollution from satellites (MAPS) experiment measured the distribution of middle tropospheric carbon monoxide (CO) from the Space Shuttle during October 1984. A critical area of the experiment is the assessment of experimental error of the MAPS data. This error is determined by the comparison between the space-based CO data and concurrent, direct CO measurements taken aboard aircraft. Because of the variability in the CO measurements near land sources, a strategy for comparing the tropospheric CO measurements over the remote oceans is presented.

  4. Pathways and Bioenergetics of Anaerobic Carbon Monoxide Fermentation.

    PubMed

    Diender, Martijn; Stams, Alfons J M; Sousa, Diana Z

    2015-01-01

    Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the potential of converting CO-rich gas, such as synthesis gas, into bio-based products. Three main types of fermentative CO metabolism can be distinguished: hydrogenogenesis, methanogenesis, and acetogenesis, generating hydrogen, methane and acetate, respectively. Here, we review the current knowledge on these three variants of microbial CO metabolism with an emphasis on the potential enzymatic routes and bio-energetics involved.

  5. Carbon Monoxide and Soot Formation in Inverse Diffusion Flames

    NASA Technical Reports Server (NTRS)

    Blevins, L. G.; Mulholland, G. W.; Davis, R. W.

    1999-01-01

    The objective of this project is to study carbon monoxide (CO) and soot formation in laminar, inverse diffusion flames (IDFs). The IDF is used because it is a special case of underventilated combustion. The microgravity environment is crucial for this study because buoyancy-induced instabilities impede systematic variation of IDF operating conditions in normal gravity. The project described in this paper is just beginning, and no results are available. Hence, the goals of this paper are to establish the motivation for the research, to review the IDF literature, and to briefly introduce the experimental and computational plan for the research.

  6. [Acute carbon monoxide poisoning after water pipe tobacco smoking].

    PubMed

    Paulsen, Jakob Felbo; Villads, Kasper von Rosen; Sonne, Morten Egede

    2016-12-05

    Carbon monoxide poisoning is potentially lethal, and early recognition and treatment is essential. An 18-year-old man was admitted due to syncope and a carboxyhaemoglobin level of 17% after water pipe tobacco smoking. He received normo- and hyperbaric oxygen as treatment and was discharged after two days without neurological sequelae. This case is the first in Denmark, but recently seven similar cases have been reported. The number of young people smoking water pipe tobacco is increasing, and we fear that more cases like this will occur in the future.

  7. Material processing with hydrogen and carbon monoxide on Mars

    NASA Technical Reports Server (NTRS)

    Hepp, Aloysius F.; Linne, Diane L.; Landis, Geoffrey A.

    1991-01-01

    Several novel proposals are examined for propellant production from carbon dioxide and monoxide and hydrogen. Potential uses were also examined of CO as a fuel or as a reducing agent in metal oxide processing as obtained or further reduced to carbon. Hydrogen can be reacted with CO to produce a wide variety of hydrocarbons, alcohols, and other organic compounds. Methanol, produced by Fischer-Tropsch chemistry may be useful as a fuel; it is easy to store and handle because it is a liquid at Mars temperatures. The reduction of CO2 to hydrocarbons such as methane or acetylene can be accomplished with hydrocarbons. Carbon monoxide and hydrogen require cryogenic temperatures for storage as liquid. Noncryogenic storage of hydrogen may be accomplished using hydrocarbons, inorganic hydrides, or metal hydrides. Noncryogenic storage of CO may be accomplished in the form of iron carbonyl (FE(CO)5) or other metal carbonyls. Low hydrogen content fuels such as acetylene (C2H2) may be effective propellants with low requirements for earth derived resources. The impact on manned Mars missions of alternative propellant production and utilization is discussed.

  8. Material processing with hydrogen and carbon monoxide on Mars

    NASA Technical Reports Server (NTRS)

    Hepp, Aloysius F.; Landis, Geoffrey A.; Linne, Diane L.

    1991-01-01

    Several novel proposals are examined for propellant production from carbon dioxide and monoxide and hydrogen. Potential uses were also examined of CO as a fuel or as a reducing agent in metal oxide processing as obtained or further reduced to carbon. Hydrogen can be reacted with CO to produce a wide variety of hydrocarbons, alcohols, and other organic compounds. Methanol, produced by Fischer-Tropsch chemistry may be useful as a fuel; it is easy to store and handle because it is a liquid at Mars temperatures. The reduction of CO2 to hydrocarbons such as methane or acetylene can be accomplished with hydrogen. Carbon monoxide and hydrogen require cryogenic temperatures for storage as liquids. Noncryogenic storage of hydrogen may be accomplished using hydrocarbons, inorganic hydrides, or metal hydrides. Noncryogenic storage of CO may be accomplished in the form of iron carbonyl (FE(CO)5) or other metal carbonyls. Low hydrogen content fuels such as acetylene (C2H2) may be effective propellants with low requirements for earth derived resources. The impact on manned Mars missions of alternative propellant production and utilization is discussed.

  9. Methanation of gas streams containing carbon monoxide and hydrogen

    DOEpatents

    Frost, Albert C.

    1983-01-01

    Carbon monoxide-containing gas streams having a relatively high concentration of hydrogen are pretreated so as to remove the hydrogen in a recoverable form for use in the second step of a cyclic, essentially two-step process for the production of methane. The thus-treated streams are then passed over a catalyst to deposit a surface layer of active surface carbon thereon essentially without the formation of inactive coke. This active carbon is reacted with said hydrogen removed from the feed gas stream to form methane. The utilization of the CO in the feed gas stream is appreciably increased, enhancing the overall process for the production of relatively pure, low-cost methane from CO-containing waste gas streams.

  10. Influence of water table on carbon dioxide, carbon monoxide, and methane fluxes from taiga bog microcosms

    SciTech Connect

    Funk, D.W.; Pullmann, E.R.; Peterson, K.M.

    1994-09-01

    Hydrological changes, particularly alterations in water table level, may largely overshadow the more direct effects of global temperature increase upon carbon cycling in arctic and subarctic wetlands. Frozen cores (n=40) of intact soils and vegetation were collected from a bog near Fairbanks, Alaska, and fluxes of CO{sub 2}, CH{sub 4}, and Co in response to water table variation were studied under controlled conditions in the Duke University phytotron. Core microcosms thawed to a 20-cm depth over 30 days under a 20 hour photoperiod with a day/night temperature regime of 20/10{degrees}C. After 30 days the water table in 20 microcosms was decreased from the soil surface to -15 cm and maintained at the soil surface in 20 control cores. Outward fluxes of CO{sub 2} (9-16 g m{sup -2}d{sup -1}) and CO (3-4 mg m{sup -2}d{sup -1}) were greatest during early thaw and decreased to near zero for both gases before the water table treatment started. Lower water table tripled CO{sub 2} flux to the atmosphere when compared with control cores. Carbon monoxide was emitted at low rates from high water table cores and consumed by low water table cores. Methane fluxes were low (<1 mg m{sup -2}d{sup -1}) in all cores during thaw. High water table cores increased CH{sub 4} flux to 8-9 mg m{sup -2}d{sup -1} over 70 days and remained high relative to the low water table cores (<0.74 mg m{sup -2}d{sup -1}). Although drying of wetland taiga soils may decrease CH{sub 4} emissions to the atmosphere, the associated increase in CO{sub 2} due to aerobic respiration will likely increase the global warming potential of gas emissions from these soils. 43 refs., 4 figs.

  11. Cardiovascular effects of chronic carbon monoxide and high-altitude exposure.

    PubMed

    McGrath, J J

    1989-07-01

    At higher altitudes, ambient carbon monoxide levels are increasing with the number of residents and tourists and their use of motor vehicles and heating devices (such as fireplaces, furnaces, and stoves). Although chronic exposure to carbon monoxide or high altitude causes pronounced cardiovascular changes in humans as well as in animals, there is little information on the effects elicited by these stressors combined. Data from acute studies and theoretical considerations suggest that carbon monoxide inhaled at altitude may be more detrimental than carbon monoxide inhaled at sea level. It is not known, however, if the cardiovascular system adapts or deteriorates with continuous, concurrent exposure to carbon monoxide and high altitude. Male laboratory rats were exposed for six weeks in steel barometric chambers to altitudes ranging from 3,300 ft (ambient) to 18,000 ft and to concentrations ranging from 0 to 500 parts per million (ppm)2. Carbon monoxide had no effect on body weight at any altitude. There was a tendency for hematocrit to increase even at the lowest concentration of carbon monoxide (9 ppm), but the increase did not become significant until 100 ppm. At 10,000 ft, there was a tendency for total heart weight to increase in rats inhaling 100 ppm carbon monoxide. Although its effects on the heart at altitude are complex, carbon monoxide, in concentrations of 500 ppm or less, had little effect on the right ventricle; it did not exacerbate any effects due to altitude. There was a tendency for the left ventricle weight to increase with exposure to 35 ppm carbon monoxide at altitude, but the increase was not significant until 100 ppm carbon monoxide. Heart rate, blood pressure, cardiac output, and peripheral resistance were unaffected by exposure to 35 ppm carbon monoxide or 10,000-ft altitude singly or in combination. I conclude that six weeks of exposure to 35 ppm carbon monoxide does not produce measurable effects in the healthy laboratory rat, nor does it

  12. A carbon monoxide passive sampler: Research and development needs

    SciTech Connect

    Traynor, G.W.; Apte, M.G.; Diamond, R.C.; Woods, A.L.

    1991-11-01

    In rare instances, carbon monoxide (CO) levels in houses can reach dangerously high concentrations, causing adverse health effects ranging from mild headaches to, under extreme conditions, death. Hundreds of fatal accidental carbon monoxide poisonings occur each year primarily due to the indoor operation of motor vehicles, the indoor use of charcoal for cooking, the operation of malfunctioning vented and unvented combustion appliances, and the misuse combustion appliances. Because there is a lack of simple, inexpensive, and accurate field sampling instrumentation, it is difficult for gas utilities and researchers to conduct field research studies designed to quantify the concentrations of CO in residences. Determining the concentration of CO in residences is the first step towards identifying the high risk appliances and high-CO environments which pose health risks. Thus, there exists an urgent need to develop and field-validate a CO-quantifying technique suitable for affordable field research. A CO passive sampler, if developed, could fulfill these requirements. Existing CO monitoring techniques are discussed as well as three potential CO-detection methods for use in a CO passive sampler. Laboratory and field research needed for the development and validation of an effective and cost-efficient CO passive sampler are also discussed.

  13. Portable device for monitoring consistency of carbon monoxide

    NASA Astrophysics Data System (ADS)

    Zheng, Qingyu; Liang, Fuping; Liu, Gang; Wang, Xiaofei

    2002-06-01

    The necessity to nondestructively monitor concentration of carbon monoxide (CO), which is a colorless, tasteless and poisonous gas and is harmful to people, is disclosed. The portable device for monitoring concentration of CO plays an important role in health care and environment supervising for civil and industrial purposes. A basic circuit-based principle for the implementation of the device is presented with a detailed analysis for the key issues in designing. Specifically, the designing for the preamplifier is of great importance to the performance of the device. There is also introduced a method for getting standard voltage value from the micro-ampere current signal outputted from a carbon monoxide sensor and for restraining other gases to exert influence on the CO monitoring. Meanwhile, the paper teaches an anti-jamming technique for eliminating interference between analog and digital circuits within a very small system. In said device, a multi-function alarm circuit, which periodically performing its self-checking function, produces alarm with sound and light if the power of a battery is insufficient or the concentration of CO is detected to be over a set threshold. In addition, the major characteristics and applications for the device are also presented.

  14. Combustion characteristics of hydrogen. Carbon monoxide based gaseous fuels

    NASA Astrophysics Data System (ADS)

    Notardonato, J. J.; White, D. J.; Kubasco, A. J.; Lecren, R. T.

    1981-10-01

    An experimental rig program was conducted with the objective of evaluating the combuston performance of a family of fuel gases based on a mixture of hydrogen and carbon monoxide. These gases, in addition to being members of a family, were also representative of those secondary fuels that could be produced from coal by various gasification schemes. In particular, simulated Winkler, Lurgi, and Blue-water low and medium energy content gases were used as fuels in the experimental combustor rig. The combustor used was originally designed as a low NOx rich-lean system for burning liquid fuels with high bound nitrogen levels. When used with the above gaseous fuels this combustor was operated in a lean-lean mode with ultra long residence times. The Blue-water gas was also operated in a rich-lean mode. The results of these tests indicate the possibility of the existence of an 'optimum' gas turbine hydrogen - carbon monoxide based secondary fuel. Such a fuel would exhibit NOx and high efficiency over the entire engine operating range. It would also have sufficient stability range to allow normal light-off and engine acceleration. Solar Turbines Incorporated would like to emphasize that the results presented here have been obtained with experimental rig combustors. The technologies generated could, however, be utilized in future commercial gas turbines.

  15. Comparative Analysis of Carbon Monoxide Tolerance among Thermoanaerobacter Species

    PubMed Central

    Alves, Joana I.; Alves, M. Madalena; Plugge, Caroline M.; Stams, Alfons J. M.; Sousa, Diana Z.

    2016-01-01

    An anaerobic thermophilic strain (strain PCO) was isolated from a syngas-converting enrichment culture. Syngas components cannot be used by strain PCO, but the new strain is very tolerant to carbon monoxide (pCO = 1.7 × 105 Pa, 100% CO). 16S rRNA gene analysis and DNA-DNA hybridization revealed that strain PCO is a strain of Thermoanaerobacter thermohydrosulfuricus. The physiology of strain PCO and other Thermoanaerobacter species was compared, focusing on their tolerance to carbon monoxide. T. thermohydrosulfuricus, T. brockii subsp. finnii, T. pseudethanolicus, and T. wiegelii were exposed to increased CO concentrations in the headspace, while growth, glucose consumption and product formation were monitored. Remarkably, glucose conversion rates by Thermoanaerobacter species were not affected by CO. All the tested strains fermented glucose to mainly lactate, ethanol, acetate, and hydrogen, but final product concentrations differed. In the presence of CO, ethanol production was generally less affected, but H2 production decreased with increasing CO partial pressure. This study highlights the CO resistance of Thermoanaerobacter species. PMID:27621723

  16. Carbon Monoxide Emissions in Middle Aged Debris Disks

    NASA Astrophysics Data System (ADS)

    Henderson, Morgan; Gorti, Uma; Hales, Antonio; Carpenter, John M.; Hughes, A. Meredith

    2017-01-01

    Circumstellar disks greater than 10 Myr old, referred to as debris disks, are expected to be gas poor. The original gas and dust in these disks is thought to be accreted onto the host stars, used up in the formation of planets and other bodies, or blown out of the disks via stellar radiation. However, recent ALMA observations at millimeter wavelengths have led to the detection of carbon monoxide (J=2-1) emission in a few debris disks, prompting further investigation.Using ALMA data, two separate models of gas genesis were tested against observations of the CO emissions in the disks around HIP 73145, HIP 76310, and HIP 84881 in the Upper Sco association. One of these models was built on the hypothesis that the gas in these debris disks is left over from stellar formation and has persisted over uncommonly long periods of time. The other model is built on the hypothesis that this gas is of secondary nature, produced by collisions between planetary bodies in the debris disks. Model emissions were calculated using the Line Modeling Engine (LIME) radiative transfer code and were compared with observational data to infer gas masses under both production scenarios. The implications of the masses of carbon monoxide in the disks suggested by each of the two models are discussed.

  17. Combustion characteristics of hydrogen. Carbon monoxide based gaseous fuels

    NASA Technical Reports Server (NTRS)

    Notardonato, J. J.; White, D. J.; Kubasco, A. J.; Lecren, R. T.

    1981-01-01

    An experimental rig program was conducted with the objective of evaluating the combuston performance of a family of fuel gases based on a mixture of hydrogen and carbon monoxide. These gases, in addition to being members of a family, were also representative of those secondary fuels that could be produced from coal by various gasification schemes. In particular, simulated Winkler, Lurgi, and Blue-water low and medium energy content gases were used as fuels in the experimental combustor rig. The combustor used was originally designed as a low NOx rich-lean system for burning liquid fuels with high bound nitrogen levels. When used with the above gaseous fuels this combustor was operated in a lean-lean mode with ultra long residence times. The Blue-water gas was also operated in a rich-lean mode. The results of these tests indicate the possibility of the existence of an 'optimum' gas turbine hydrogen - carbon monoxide based secondary fuel. Such a fuel would exhibit NOx and high efficiency over the entire engine operating range. It would also have sufficient stability range to allow normal light-off and engine acceleration. Solar Turbines Incorporated would like to emphasize that the results presented here have been obtained with experimental rig combustors. The technologies generated could, however, be utilized in future commercial gas turbines.

  18. Removal of carbon monoxide. Physical adsorption on natural and synthetic zeolites

    NASA Technical Reports Server (NTRS)

    Alfani, F.; Greco, G., Jr.; Iroio, G.

    1982-01-01

    The utilization of natural zeolite materials in the elimination of polluting gases is investigated. Carbon monoxide pollution is emphasized because its concentration may reach dangerous levels in places such as vehicle tunnels, underground parking lots, etc. The elimination of carbon monoxide is also of interest in some industrial processes relating to the production of pure gases.

  19. Emission of methane, carbon monoxide, carbon dioxide and short‐chain hydrocarbons from vegetation foliage under ultraviolet irradiation

    PubMed Central

    FRASER, WESLEY T.; BLEI, EMANUEL; FRY, STEPHEN C.; NEWMAN, MARK F.; REAY, DAVID S.; SMITH, KEITH A.

    2015-01-01

    Abstract The original report that plants emit methane (CH 4) under aerobic conditions caused much debate and controversy. Critics questioned experimental techniques, possible mechanisms for CH 4 production and the nature of estimating global emissions. Several studies have now confirmed that aerobic CH 4 emissions can be detected from plant foliage but the extent of the phenomenon in plants and the precise mechanisms and precursors involved remain uncertain. In this study, we investigated the role of environmentally realistic levels of ultraviolet (UV) radiation in causing the emission of CH 4 and other gases from foliage obtained from a wide variety of plant types. We related our measured emissions to the foliar content of methyl esters and lignin and to the epidermal UV absorbance of the species investigated. Our data demonstrate that the terrestrial vegetation foliage sampled did emit CH 4, with a range in emissions of 0.6–31.8 ng CH 4 g−1 leaf DW h−1, which compares favourably with the original reports of experimental work. In addition to CH 4 emissions, our data show that carbon monoxide, ethene and propane are also emitted under UV stress but we detected no significant emissions of carbon dioxide or ethane. PMID:25443986

  20. Four-electron deoxygenative reductive coupling of carbon monoxide at a single metal site

    NASA Astrophysics Data System (ADS)

    Buss, Joshua A.; Agapie, Theodor

    2016-01-01

    Carbon dioxide is the ultimate source of the fossil fuels that are both central to modern life and problematic: their use increases atmospheric levels of greenhouse gases, and their availability is geopolitically constrained. Using carbon dioxide as a feedstock to produce synthetic fuels might, in principle, alleviate these concerns. Although many homogeneous and heterogeneous catalysts convert carbon dioxide to carbon monoxide, further deoxygenative coupling of carbon monoxide to generate useful multicarbon products is challenging. Molybdenum and vanadium nitrogenases are capable of converting carbon monoxide into hydrocarbons under mild conditions, using discrete electron and proton sources. Electrocatalytic reduction of carbon monoxide on copper catalysts also uses a combination of electrons and protons, while the industrial Fischer-Tropsch process uses dihydrogen as a combined source of electrons and electrophiles for carbon monoxide coupling at high temperatures and pressures. However, these enzymatic and heterogeneous systems are difficult to probe mechanistically. Molecular catalysts have been studied extensively to investigate the elementary steps by which carbon monoxide is deoxygenated and coupled, but a single metal site that can efficiently induce the required scission of carbon-oxygen bonds and generate carbon-carbon bonds has not yet been documented. Here we describe a molybdenum compound, supported by a terphenyl-diphosphine ligand, that activates and cleaves the strong carbon-oxygen bond of carbon monoxide, enacts carbon-carbon coupling, and spontaneously dissociates the resulting fragment. This complex four-electron transformation is enabled by the terphenyl-diphosphine ligand, which acts as an electron reservoir and exhibits the coordinative flexibility needed to stabilize the different intermediates involved in the overall reaction sequence. We anticipate that these design elements might help in the development of efficient catalysts for

  1. Carbon monoxide exposure of subjects with documented cardiac arrhythmias. Research report, August 1987-July 1991

    SciTech Connect

    Chaitman, B.R.; Dahms, T.E.; Byers, S.; Carroll, L.W.; Younis, L.T.

    1992-09-01

    The authors studied 30 subjects with well-documented coronary artery disease who had an average of at least 30 ventricular ectopic beats per hour over a 20-hour monitoring interval. Subjects were selected and enrolled in a randomized double-blind study; the carbon monoxide exposure was designed to result in 3% or 5% carboxyhemoglobin levels, as measured by gas chromatography. Total and repetitive ventricular arrhythmias were measured for four specific time intervals: (1) two hours before carbon monoxide exposure; (2) during the two-hour carbon monoxide exposure; (3) six hours after carbon monoxide exposure; and (4) approximately 10 hours after exposure, or the remaining recording interval on the Holter monitor. There was no increase in ventricular arrhythmia frequency after carbon monoxide exposure, regardless of the level of carboxyhemoglobin or the type of activity. During steady-state conditions at rest, the number of ventricular ectopic beats per hour was 115 + or - 153 (SD) for room air exposure (0.7% carboxyhemoglobin), 121 + or - 171 for the lower carbon monoxide exposure (3.2% carboxyhemoglobin), and 94 + or - 129 for the higher carbon monoxide exposure (5.1% carboxyhemoglobin). The frequency of complex ventricular ectopy was not altered at the levels of carbon monoxide studied. Secondary analysis of the impact of carbon monoxide on ventricular ectopic beat frequency stratified by baseline ejection fraction, baseline ventricular ectopic beat frequency, and exercise-induced ST-segment changes did not indicate an effect of carbon monoxide on ventricular arrhythmias. However, patients with symptomatic ventricular arrhythmias and symptomatic myocardial ischemia were excluded from the present study.

  2. Nitrogen monoxide and carbon monoxide transfer interpretation: state of the art.

    PubMed

    Martinot, Jean Benoit; Guénard, Hervé; Dinh-Xuan, Anh-Tuan; Gin, Henri; Dromer, Claire

    2015-11-17

    Just a few clinicians routinely measure the subcomponents of the lung diffusing capacity for Carbone monoxide (DLCO ). This is because the measurement of membrane and blood conductances for CO (DmCO and DbCO  = θCO  × Vc , respectively) by the classic Roughton and Forster method is complicated and time consuming. In addition, it mistakenly assumes a close relationship between alveolar oxygen partial pressure (PAO2 ) and mean intracapillary oxygen partial pressure (PcapO2 ) which is the true determinant of specific conductance of haemoglobin for CO (θCO ). Besides that, the critical multistep oxygenation method along with different linear equations relating 1/θCO to PcapO2 gave highly scattered DmCO and Vc values. The Dm and Vc can also be derived from a simultaneous measurement of DLNO and DLCO with the blood resistance for NO assumed to be negligible. However, recent in vitro and in vivo experiments point towards a finite value of θNO (about 4·5 mlNO  × mlblood(-1)  × min(-1)  × mmHg(-1) ). Putting together the arguments and our clinical data allows us to report here the state of the art in partitioning the CO diffusing capacity into its constitutive components, with the goal to encourage further studies examining the sensitivity of DmCO and Vc to alterations observed in parenchymal diseases.

  3. 40 CFR 415.330 - Applicability; description of the carbon monoxide and by-product hydrogen production subcategory.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... carbon monoxide and by-product hydrogen production subcategory. 415.330 Section 415.330 Protection of... MANUFACTURING POINT SOURCE CATEGORY Carbon Monoxide and By-Product Hydrogen Production Subcategory § 415.330 Applicability; description of the carbon monoxide and by-product hydrogen production subcategory. The...

  4. 40 CFR 415.330 - Applicability; description of the carbon monoxide and by-product hydrogen production subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... carbon monoxide and by-product hydrogen production subcategory. 415.330 Section 415.330 Protection of... MANUFACTURING POINT SOURCE CATEGORY Carbon Monoxide and By-Product Hydrogen Production Subcategory § 415.330 Applicability; description of the carbon monoxide and by-product hydrogen production subcategory. The...

  5. 40 CFR 415.330 - Applicability; description of the carbon monoxide and by-product hydrogen production subcategory.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... carbon monoxide and by-product hydrogen production subcategory. 415.330 Section 415.330 Protection of... MANUFACTURING POINT SOURCE CATEGORY Carbon Monoxide and By-Product Hydrogen Production Subcategory § 415.330 Applicability; description of the carbon monoxide and by-product hydrogen production subcategory. The...

  6. 40 CFR 415.330 - Applicability; description of the carbon monoxide and by-product hydrogen production subcategory.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... carbon monoxide and by-product hydrogen production subcategory. 415.330 Section 415.330 Protection of... MANUFACTURING POINT SOURCE CATEGORY Carbon Monoxide and By-Product Hydrogen Production Subcategory § 415.330 Applicability; description of the carbon monoxide and by-product hydrogen production subcategory. The...

  7. 40 CFR 415.330 - Applicability; description of the carbon monoxide and by-product hydrogen production subcategory.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... carbon monoxide and by-product hydrogen production subcategory. 415.330 Section 415.330 Protection of... MANUFACTURING POINT SOURCE CATEGORY Carbon Monoxide and By-Product Hydrogen Production Subcategory § 415.330 Applicability; description of the carbon monoxide and by-product hydrogen production subcategory. The...

  8. 40 CFR 89.112 - Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Oxides of nitrogen, carbon monoxide....112 Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission... emissions of oxides of nitrogen, carbon monoxide, hydrocarbon, and nonmethane hydrocarbon are measured...

  9. 40 CFR 89.112 - Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Oxides of nitrogen, carbon monoxide....112 Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission... emissions of oxides of nitrogen, carbon monoxide, hydrocarbon, and nonmethane hydrocarbon are measured...

  10. 40 CFR 89.112 - Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Oxides of nitrogen, carbon monoxide....112 Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission... emissions of oxides of nitrogen, carbon monoxide, hydrocarbon, and nonmethane hydrocarbon are measured...

  11. 40 CFR 89.112 - Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Oxides of nitrogen, carbon monoxide....112 Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission... emissions of oxides of nitrogen, carbon monoxide, hydrocarbon, and nonmethane hydrocarbon are measured...

  12. 40 CFR 89.112 - Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Oxides of nitrogen, carbon monoxide....112 Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission... emissions of oxides of nitrogen, carbon monoxide, hydrocarbon, and nonmethane hydrocarbon are measured...

  13. Measurement of endogenous carbon monoxide formation in biological systems.

    PubMed

    Marks, Gerald S; Vreman, Hendrik J; McLaughlin, Brian E; Brien, James F; Nakatsu, Kanji

    2002-04-01

    Endogenous carbon monoxide (CO) formation has been measured in different biological systems using a variety of analytical procedures. The methods include gas chromatography-reduction gas detection, gas chromatography-mass spectroscopic detection, laser sensor-infrared absorption, UV-visible spectrophotometric measurement of CO-hemoglobin or CO-myoglobin complex, and formation of (14)CO from (14)C-heme formed following [2-(14)C]glycine administration. CO formation ranged from a low of 0.029 nmol/mg of protein/h in chorionic villi of term human placenta to a high of 0.28 nmol/mg of protein/h in rat olfactory receptor neurons in culture and rat liver perfusate.

  14. The oxidation of carbon monoxide using a tin oxide catalyst

    NASA Technical Reports Server (NTRS)

    Sampson, Christopher F.; Gudde, Nicholas J.

    1987-01-01

    This paper outlines some of the steps involved in the development by the United Kingdom Atomic Energy Authority (UKAEA) of a catalytic device for the recombination of carbon monoxide and oxygen in a CO2 laser system. It contrasts the differences between CO oxidation for air purification and for laser environmental control, but indicates that there are similarities between the physical specifications. The principal features of catalytic devices are outlined and some experimental work described. This includes measurements concerning the structure and mechanical properties of the artifact, the preparation of the catalyst coating and its interaction with the gaseous environment. The paper concludes with some speculation about the method by which the reaction actually occurs.

  15. Carbon monoxide expedites metabolic exhaustion to inhibit tumor growth.

    PubMed

    Wegiel, Barbara; Gallo, David; Csizmadia, Eva; Harris, Clair; Belcher, John; Vercellotti, Gregory M; Penacho, Nuno; Seth, Pankaj; Sukhatme, Vikas; Ahmed, Asif; Pandolfi, Pier Paolo; Helczynski, Leszek; Bjartell, Anders; Persson, Jenny Liao; Otterbein, Leo E

    2013-12-01

    One classical feature of cancer cells is their metabolic acquisition of a highly glycolytic phenotype. Carbon monoxide (CO), one of the products of the cytoprotective molecule heme oxygenase-1 (HO-1) in cancer cells, has been implicated in carcinogenesis and therapeutic resistance. However, the functional contributions of CO and HO-1 to these processes are poorly defined. In human prostate cancers, we found that HO-1 was nuclear localized in malignant cells, with low enzymatic activity in moderately differentiated tumors correlating with relatively worse clinical outcomes. Exposure to CO sensitized prostate cancer cells but not normal cells to chemotherapy, with growth arrest and apoptosis induced in vivo in part through mitotic catastrophe. CO targeted mitochondria activity in cancer cells as evidenced by higher oxygen consumption, free radical generation, and mitochondrial collapse. Collectively, our findings indicated that CO transiently induces an anti-Warburg effect by rapidly fueling cancer cell bioenergetics, ultimately resulting in metabolic exhaustion.

  16. Carbon monoxide: a role in carotid body chemoreception.

    PubMed

    Prabhakar, N R; Dinerman, J L; Agani, F H; Snyder, S H

    1995-03-14

    Carbon monoxide (CO), produced endogenously by heme oxygenase, has been implicated as a neuronal messenger. Carotid bodies are sensory organs that regulate ventilation by responding to alterations of blood oxygen, CO2, and pH. Changes in blood gases are sensed by glomus cells in the carotid body that synapse on afferent terminals of the carotid sinus nerve that projects to respiratory-related neurons in the brainstem. Using immunocytochemistry, we demonstrate that heme oxygenase 2 is localized to glomus cells in the cat and rat carotid bodies. Physiological studies show that zinc protoporphyrin IX, a potent heme oxygenase inhibitor, markedly increases carotid body sensory activity, while copper protoporphyrin IX, which does not inhibit the enzyme, is inactive. Exogenous CO reverses the stimulatory effects of zinc protoporphyrin IX. These results suggest that glomus cells are capable of synthesizing CO and endogenous CO appears to be a physiologic regulator of carotid body sensory activity.

  17. Venus - Detection of variations in stratospheric carbon monoxide

    NASA Technical Reports Server (NTRS)

    Gulkis, S.; Kakar, R. K.; Klein, M. J.; Olsen, E. T.; Wilson, W. J.

    1978-01-01

    The reported observations of the J = 0-1 rotational transition (115271.2 MHz) of carbon monoxide in the Venusian atmosphere indicate that the distribution of stratospheric CO is variable. Observations were obtained with a 11-m antenna on several days in February 1977, when Venus was near maximum eastern elongation (k approximately 0.4), and in April 1977 during inferior conjunction (k approximately 0.01). Differences in the line intensities and shapes for the two data sets are described. The results are interpreted to suggest that on the nightside of Venus there is relatively more CO at higher altitudes and relatively less CO at lower altitudes than on the dayside of the planet.

  18. Carbon monoxide in an extremely metal-poor galaxy.

    PubMed

    Shi, Yong; Wang, Junzhi; Zhang, Zhi-Yu; Gao, Yu; Hao, Cai-Na; Xia, Xiao-Yang; Gu, Qiusheng

    2016-12-09

    Extremely metal-poor galaxies with metallicity below 10% of the solar value in the local universe are the best analogues to investigating the interstellar medium at a quasi-primitive environment in the early universe. In spite of the ongoing formation of stars in these galaxies, the presence of molecular gas (which is known to provide the material reservoir for star formation in galaxies such as our Milky Way) remains unclear. Here we report the detection of carbon monoxide (CO), the primary tracer of molecular gas, in a galaxy with 7% solar metallicity, with additional detections in two galaxies at higher metallicities. Such detections offer direct evidence for the existence of molecular gas in these galaxies that contain few metals. Using archived infrared data, it is shown that the molecular gas mass per CO luminosity at extremely low metallicity is approximately one-thousand times the Milky Way value.

  19. Size Effect of Ruthenium Nanoparticles in Catalytic Carbon Monoxide Oxidation

    SciTech Connect

    Joo, Sang Hoon; Park, Jeong Y.; Renzas, J. Russell; Butcher, Derek R.; Huang, Wenyu; Somorjai, Gabor A.

    2010-04-04

    Carbon monoxide oxidation over ruthenium catalysts has shown an unusual catalytic behavior. Here we report a particle size effect on CO oxidation over Ru nanoparticle (NP) catalysts. Uniform Ru NPs with a tunable particle size from 2 to 6 nm were synthesized by a polyol reduction of Ru(acac){sub 3} precursor in the presence of poly(vinylpyrrolidone) stabilizer. The measurement of catalytic activity of CO oxidation over two-dimensional Ru NPs arrays under oxidizing reaction conditions (40 Torr CO and 100 Torr O{sub 2}) showed an activity dependence on the Ru NP size. The CO oxidation activity increases with NP size, and the 6 nm Ru NP catalyst shows 8-fold higher activity than the 2 nm catalysts. The results gained from this study will provide the scientific basis for future design of Ru-based oxidation catalysts.

  20. Carbon Monoxide as a Signaling Molecule in Plants

    PubMed Central

    Wang, Meng; Liao, Weibiao

    2016-01-01

    Carbon monoxide (CO), a gaseous molecule, has emerged as a signaling molecule in plants, due to its ability to trigger a series of physiological reactions. This article provides a brief update on the synthesis of CO, its physiological functions in plant growth and development, as well as its roles in abiotic stress tolerance such as drought, salt, ultraviolet radiation, and heavy metal stress. CO has positive effects on seed germination, root development, and stomatal closure. Also, CO can enhance plant abiotic stress resistance commonly through the enhancement of antioxidant defense system. Moreover, CO shows cross talk with other signaling molecules including NO, phytohormones (IAA, ABA, and GA) and other gas signaling molecules (H2S, H2, CH4). PMID:27200045

  1. Carbon monoxide in an extremely metal-poor galaxy

    PubMed Central

    Shi, Yong; Wang, Junzhi; Zhang, Zhi-Yu; Gao, Yu; Hao, Cai-Na; Xia, Xiao-Yang; Gu, Qiusheng

    2016-01-01

    Extremely metal-poor galaxies with metallicity below 10% of the solar value in the local universe are the best analogues to investigating the interstellar medium at a quasi-primitive environment in the early universe. In spite of the ongoing formation of stars in these galaxies, the presence of molecular gas (which is known to provide the material reservoir for star formation in galaxies such as our Milky Way) remains unclear. Here we report the detection of carbon monoxide (CO), the primary tracer of molecular gas, in a galaxy with 7% solar metallicity, with additional detections in two galaxies at higher metallicities. Such detections offer direct evidence for the existence of molecular gas in these galaxies that contain few metals. Using archived infrared data, it is shown that the molecular gas mass per CO luminosity at extremely low metallicity is approximately one-thousand times the Milky Way value. PMID:27934880

  2. [Etiology of combined inhalational hydrocyanic acid and carbon monoxide poisoning].

    PubMed

    Sigrist, T; Dirnhofer, R

    1979-01-01

    A young man was found dead in a kitchen, that was partly burnt. Autopsy revealed, as cause of death, a combined intoxication following inhalation of carbon monoxide and hydrocyanic acid. Own investigations on the pyrolysis of pieces of furniture found in the kitchen (plastic plates containing melamine and plates containing formaldehyde) showed, that hydrocyanic acid was liberated through combustion of such substances and inhaled by the victim. The poisoning picture is discussed, and discussion includes especially considerations on the peculiar sensitivity of the brain toward the action of hydrocyanic acid and the relative insensitivity of the heart muscle. It is thought that the cause of such sensitivity difference lies in the physiological differences of the intracellular energy production. Finally the dangers of combustion gases developing from burning plastic materials are reemphasized.

  3. Carbon monoxide measurement in the global atmospheric sampling program

    NASA Technical Reports Server (NTRS)

    Dudzinski, T. J.

    1979-01-01

    The carbon monoxide measurement system used in the NASA Global Atmospheric Sampling Program (GASP) is described. The system used a modified version of a commercially available infrared absorption analyzer. The modifications increased the sensitivity of the analyzer to 1 ppmv full scale, with a limit of detectability of 0.02 ppmv. Packaging was modified for automatic, unattended operation in an aircraft environment. The GASP system is described along with analyzer operation, calibration procedures, and measurement errors. Uncertainty of the CO measurement over a 2-year period ranged from + or - 3 to + or - 13 percent of reading, plus an error due to random fluctuation of the output signal + or - 3 to + or - 15 ppbv.

  4. UV-induced carbon monoxide emission from living vegetation

    NASA Astrophysics Data System (ADS)

    Bruhn, D.; Albert, K. R.; Mikkelsen, T. N.; Ambus, P.

    2013-06-01

    The global burden of carbon monoxide (CO) is rather uncertain. In this paper we address the potential for UV-induced CO emission by living terrestrial vegetation surfaces. Real-time measurements of CO concentrations were made with a cavity enhanced laser spectrometer connected in closed loop to either an ecosystem chamber or a plant-leaf scale chamber. Leaves of all examined plant species exhibited emission of CO in response to artificial UV-radiation as well as the UV-component of natural solar radiation. The UV-induced rate of CO emission exhibited a rather low dependence on temperature, indicating an abiotic process. The emission of CO in response to the UV-component of natural solar radiation was also evident at the ecosystem scale.

  5. Detection of the J = 6. -->. 5 transition of carbon monoxide

    SciTech Connect

    Goldsmith, P.F.; Erickson, N.R.; Fetterman, H.R.; Clifton, B.J.; Peck, D.D.; Tannenwald, P.E.; Koepf, G.A.; Buhl, D.; McAvoy, N.

    1981-01-15

    The J = 6..-->..5 rotational transition of carbon monoxide has been detected in emission from the KL ''plateau source'' in the Orion molecular cloud. The corrected peak antenna temperature is 100 K, and the FWHM line width is 26 km s/sup -1/. These observations were carried out using the 3 m telescope of the NASA IRTF (Infrared Telescope Facility) on Mauna Kea, Hawaii, and constitute the first astronomical data obtained at submillimeter wavelengths with a heterodyne system using a laser local oscillator. Our data support the idea that the high-velocity dispersion CO in Orion is optically thin and set a lower limit to its temperature of approx.180 K.

  6. The effect of carbon monoxide on planetary haze formation

    SciTech Connect

    Hörst, S. M.; Tolbert, M. A

    2014-01-20

    Organic haze plays a key role in many planetary processes ranging from influencing the radiation budget of an atmosphere to serving as a source of prebiotic molecules on the surface. Numerous experiments have investigated the aerosols produced by exposing mixtures of N{sub 2}/CH{sub 4} to a variety of energy sources. However, many N{sub 2}/CH{sub 4} atmospheres in both our solar system and extrasolar planetary systems also contain carbon monoxide (CO). We have conducted a series of atmosphere simulation experiments to investigate the effect of CO on the formation and particle size of planetary haze analogues for a range of CO mixing ratios using two different energy sources, spark discharge and UV. We find that CO strongly affects both number density and particle size of the aerosols produced in our experiments and indicates that CO may play an important, previously unexplored, role in aerosol chemistry in planetary atmospheres.

  7. Adsorption of carbon monoxide on activated carbon tin ligand

    NASA Astrophysics Data System (ADS)

    Mohamad, A. B.; Iyuke, S. E.; Daud, W. R. W.; Kadhum, A. A. H.; Fisal, Z.; Al-Khatib, M. F.; Shariff, A. M.

    2000-09-01

    Activated carbon was impregnated with 34.57% SnCl 2·2H 2O salt and then dried at 180°C to produce AC-SnO 2 to improve its adsorptive interaction with CO. Besides the fact that activated carbon has its original different pore sizes for normal gas phase CO adsorption (as in the case of pure carbon), the impregnated carbon has additional CO adsorption ability due to the presence of O -(ads) on the active sites. AC-SnO 2 proved to be a superior adsorber of CO than pure carbon when used for H 2 purification in a PSA system. Discernibly, the high adsorptive selectivity of AC-SnO 2 towards gas phase CO portrays a good future for the applicability of this noble adsorbent, since CO has become a notorious threat to the global ecosystem due to the current level of air pollution.

  8. Iron Catalyst Chemistry in High Pressure Carbon Monoxide Nanotube Reactor

    NASA Technical Reports Server (NTRS)

    Scott, Carl D.; Povitsky, Alexander; Dateo, Christopher; Gokcen, Tahir; Smalley, Richard E.

    2001-01-01

    The high-pressure carbon monoxide (HiPco) technique for producing single wall carbon nanotubes (SWNT) is analyzed using a chemical reaction model coupled with properties calculated along streamlines. Streamline properties for mixing jets are calculated by the FLUENT code using the k-e turbulent model for pure carbon monixide. The HiPco process introduces cold iron pentacarbonyl diluted in CO, or alternatively nitrogen, at high pressure, ca. 30 atmospheres into a conical mixing zone. Hot CO is also introduced via three jets at angles with respect to the axis of the reactor. Hot CO decomposes the Fe(CO)5 to release atomic Fe. Cluster reaction rates are from Krestinin, et aI., based on shock tube measurements. Another model is from classical cluster theory given by Girshick's team. The calculations are performed on streamlines that assume that a cold mixture of Fe(CO)5 in CO is introduced along the reactor axis. Then iron forms clusters that catalyze the formation of SWNTs from the Boudouard reaction on Fe-containing clusters by reaction with CO. To simulate the chemical process along streamlines that were calculated by the fluid dynamics code FLUENT, a time history of temperature and dilution are determined along streamlines. Alternative catalyst injection schemes are also evaluated.

  9. A review on engineering of cellulosic cigarette paper to reduce carbon monoxide delivery of cigarettes.

    PubMed

    Shen, Jing; Li, Jinsong; Qian, Xueren; Ren, Wanshan; Fatehi, Pedram

    2014-01-30

    In cigarette production, the cellulosic paper essentially derived from flax fibers or other fiber materials is used as the wrapping material. During smoking of cigarettes, the highly toxic carbon monoxide is produced. To decrease the amount of carbon monoxide emission in the mainstream smoke, the engineering of all cigarette components including cellulosic cigarette paper and tobacco column is critical. This review summarizes the concepts related to engineering of cigarette paper. These mainly include permeability control, increased use of burn additives, optimization of fiber basis weight, engineering of calcium carbonate fillers, and incorporation of catalysts/oxidants. In particular, catalytic and/or oxidative conversion of carbon monoxide to carbon dioxide has been very widely reported. The control of permeability/diffusivity of cigarette paper is also of critical importance for enhanced diffusion of carbon monoxide out of the cigarette. The development of new concepts and combination of various concepts may lead to breakthroughs in this area.

  10. The combined effect of noise and carbon monoxide on hearing thresholds of exposed workers

    NASA Astrophysics Data System (ADS)

    Lacerda, Adriana; Leroux, Tony; Gagn, Jean-Pierre

    2005-04-01

    Animal models have been used to demonstrate the potentiation of noise-induced hearing loss (NIHL) by carbon monoxide. It has been shown that the addition of carbon monoxide to otherwise safe noise exposure levels produces significant NIHL in rats. However, the effects of chronic exposure to low level of carbon monoxide in a noisy work environment are still unknown. The aim of this study was to compare the hearing thresholds of a group of workers exposed to noise and carbon monoxide (Group 1) to another group of workers where carbon monoxide exposure is absent or negligible (Group 2). The analysis was based on 9396 audiograms collected by the Quebec National Public Health Institute between 1983 and 1996. The results show significantly poorer hearing thresholds at high frequencies (3, 4, and 6 kHz) for the carbon monoxide exposed group (p<0.001). The potentiation effect also varied according to years of exposure in work place; a larger effect is observed for workers with between 15 to 20 years of exposure (p<0.001). This study provides the first demonstration of a potentiation effect of NIHL by carbon monoxide in humans.

  11. Regional studies of potential carbon monoxide sources based on Space Shuttle and aircraft measurements

    NASA Technical Reports Server (NTRS)

    Newell, R. E.; Shipley, S. T.; Connors, V. S.; Reichle, H. G., Jr.

    1988-01-01

    Carbon monoxide measurements made from the Space Shuttle show maxima over South America, central Africa, the eastern Mediterranean, and China. The maxima appear to be associated with either concomitant or prior convection in the air masses which carries boundary layer air into the upper troposphere. Previous aircraft measurements of carbon monoxide and ozone over South America are shown to be consistent with this view. In the tropics the three regions of long-term mean rising motion, which form part of the Walker circulation, are associated with elevated carbon monoxide.

  12. Regional studies of potential carbon monoxide sources based on Space Shuttle and aircraft measurements

    NASA Technical Reports Server (NTRS)

    Newell, R. E.; Shipley, S. T.; Connors, V. S.; Reichle, H. G., Jr.

    1988-01-01

    Carbon monoxide measurements made from the space shuttle show maxima over South America, central Africa, the eastern Mediterranean, and China. The maxima appear to be associated with either concomitant or prior convection in the air masses which carries boundary layer air into the upper troposphere. Previous aircraft measurements of carbon monoxide and ozone over South America are shown to be consistent with this view. In the tropics the three regions of long-term mean rising motion, which form part of the Walker circulation, are associated with elevated carbon monoxide.

  13. Aerobic microbial mineralization of dichloroethene as sole carbon substrate

    USGS Publications Warehouse

    Bradley, P.M.; Chapelle, F.H.

    2000-01-01

    Microorganisms indigenous to the bed sediments of a black- water stream utilized 1,2-dichloroethene (1,2-DCE) as a sole carbon substrate for aerobic metabolism. Although no evidence of growth was observed in the minimal salts culture media used in this study, efficient aerobic microbial mineralization of 1,2-DCE as sole carbon substrate was maintained through three sequential transfers (107 final dilution) of the original environmental innoculum. These results indicate that 1,2-DCE can be utilized as a primary substrate to support microbial metabolism under aerobic conditions.Microorganisms indigenous to the bed sediments of a black-water stream utilized 1,2-dichloroethene (1,2-DCE) as a sole carbon substrate for aerobic metabolism. Although no evidence of growth was observed in the minimal salts culture media used in this study, efficient aerobic microbial mineralization of 1,2-DCE as sole carbon substrate was maintained through three sequential transfers (107 final dilution) of the original environmental innoculum. These results indicate that 1,2-DCE can be utilized as a primary substrate to support microbial metabolism under aerobic conditions.

  14. Rationalizing Burned Carbon with Carbon Monoxide Exported from South America

    NASA Technical Reports Server (NTRS)

    Chatfield, R.; Freitas, S. R.; SilvaDias, M. A.; SilvaDias, P. O.; Hipskind, R. Stephen (Technical Monitor)

    2002-01-01

    We present several estimates cross-checking the fluxes of carbon to the atmosphere from burning, comparing models that are based on simple land-surface parameterizations and atmospheric transport dynamics. Both estimates made by NASA Ames and USP modeling techniques are quite high compared to some detailed satellite/land-use studies of emissions. The flux of carbon liberated to the atmosphere via biomass burning is important for several reasons. This flux is a fundamental statistic for the parameterization of the large-scale flux of gases controlling the reactive greenhouse gases methane and ozone. Similarly, it is central to the estimation of the translocation of nitrogen and pyrodenitrification in the tropics. Thirdly, CO2 emitted from rainforest clearing contributes directly to carbon lost from the rainforest system as it contributes to greenhouse gas forcing. While CO2 from pasturage, agriculture, etc, is considered to be reabsorbed seasonally, and so "off budget" for the carbon cycle, it must also be accounted. CO2 anomalies related to daily weather and interannual climatic variation are strong enough to perturb our scientific perception of long-term carbon storage trends. We compare fluxes deduced from land-use statistics (originally, W.M. Hao) and from satellite hot pixels (A. Setzer) with atmospheric fluxes determined by the mesoscale/continental scale models RAMS and MM5, and point to some new work with highly resolved global models (the NASA Data Assimilation Office's GEOS4). Our simulations are tied to events, so that measured tracers like CO tie the models directly to the burning and meteorology of a specific period. We point out a particular sensitivity in estimates based on CO, and indicate how analysis of CO2 along with other biomass-burning tracers may lead to an improved multi-species estimator of carbon burned.

  15. Interannual Variations of MLS Carbon Monoxide Induced by Solar Cycle

    NASA Technical Reports Server (NTRS)

    Lee, Jae N.; Wu, Dong L.; Ruzmaikin, Alexander

    2013-01-01

    More than eight years (2004-2012) of carbon monoxide (CO) measurements from the Aura Microwave Limb Sounder (MLS) are analyzed. The mesospheric CO, largely produced by the carbon dioxide (CO2) photolysis in the lower thermosphere, is sensitive to the solar irradiance variability. The long-term variation of observed mesospheric MLS CO concentrations at high latitudes is likely driven by the solar-cycle modulated UV forcing. Despite of different CO abundances in the southern and northern hemispheric winter, the solar-cycle dependence appears to be similar. This solar signal is further carried down to the lower altitudes by the dynamical descent in the winter polar vortex. Aura MLS CO is compared with the Solar Radiation and Climate Experiment (SORCE) total solar irradiance (TSI) and also with the spectral irradiance in the far ultraviolet (FUV) region from the SORCE Solar-Stellar Irradiance Comparison Experiment (SOLSTICE). Significant positive correlation (up to 0.6) is found between CO and FUVTSI in a large part of the upper atmosphere. The distribution of this positive correlation in the mesosphere is consistent with the expectation of CO changes induced by the solar irradiance variations.

  16. COSMIC: Carbon Monoxide and Soot in Microgravity Inverse Combustion

    NASA Technical Reports Server (NTRS)

    Blevins, L. G.; Fernandez, M. G.; Mulholland, G. W.; Davis, R. W.; Moore, E. F.; Steel, E. B.; Scott, J. H. J.

    2001-01-01

    Almost seventy percent of deaths in accidental fires are caused by inhalation of toxins such as carbon monoxide (CO) and smoke (soot) that form during underventilated burning. The COSMIC project examines the formation mechanisms of CO and soot during underventilated combustion, achieved presently using laminar, inverse diffusion flames (IDFs) formed between an air jet and surrounding fuel. A major hypothesis of the project is that the IDF mimics underventilated combustion because carbon-containing species that form on the fuel side of the flame (such as CO and soot) can escape without passing through an oxidizing flame tip. An IDF literature review was presented at the last microgravity workshop, and a few additional IDF papers have appeared since that meeting. The COSMIC project is entering the third year of its four-year funding cycle. The first two years have been devoted to designing and constructing a rig for use in the NASA 2.2-second drop tower. A few computations and laboratory experiments have been performed. The goals of this paper are to discuss the use of numerical simulation during burner design, to present computational and experimental results that support the hypothesis that IDFs are similar to underventilated flames, and to delineate future plans.

  17. Triton's Summer Sky of Methane and Carbon Monoxide

    NASA Astrophysics Data System (ADS)

    2010-04-01

    According to the first ever infrared analysis of the atmosphere of Neptune's moon Triton, summer is in full swing in its southern hemisphere. The European observing team used ESO's Very Large Telescope and discovered carbon monoxide and made the first ground-based detection of methane in Triton's thin atmosphere. These observations revealed that the thin atmosphere varies seasonally, thickening when warmed. "We have found real evidence that the Sun still makes its presence felt on Triton, even from so far away. This icy moon actually has seasons just as we do on Earth, but they change far more slowly," says Emmanuel Lellouch, the lead author of the paper reporting these results in Astronomy & Astrophysics. On Triton, where the average surface temperature is about minus 235 degrees Celsius, it is currently summer in the southern hemisphere and winter in the northern. As Triton's southern hemisphere warms up, a thin layer of frozen nitrogen, methane, and carbon monoxide on Triton's surface sublimates into gas, thickening the icy atmosphere as the season progresses during Neptune's 165-year orbit around the Sun. A season on Triton lasts a little over 40 years, and Triton passed the southern summer solstice in 2000. Based on the amount of gas measured, Lellouch and his colleagues estimate that Triton's atmospheric pressure may have risen by a factor of four compared to the measurements made by Voyager 2 in 1989, when it was still spring on the giant moon. The atmospheric pressure on Triton is now between 40 and 65 microbars - 20 000 times less than on Earth. Carbon monoxide was known to be present as ice on the surface, but Lellouch and his team discovered that Triton's upper surface layer is enriched with carbon monoxide ice by about a factor of ten compared to the deeper layers, and that it is this upper "film" that feeds the atmosphere. While the majority of Triton's atmosphere is nitrogen (much like on Earth), the methane in the atmosphere, first detected by

  18. Cyclic process for producing methane from carbon monoxide with heat removal

    DOEpatents

    Frost, Albert C.; Yang, Chang-lee

    1982-01-01

    Carbon monoxide-containing gas streams are converted to methane by a cyclic, essentially two-step process in which said carbon monoxide is disproportionated to form carbon dioxide and active surface carbon deposited on the surface of a catalyst, and said carbon is reacted with steam to form product methane and by-product carbon dioxide. The exothermic heat of reaction generated in each step is effectively removed during each complete cycle so as to avoid a build up of heat from cycle-to-cycle, with particularly advantageous techniques being employed for fixed bed, tubular and fluidized bed reactor operations.

  19. Substitution of silver for copper in the binuclear Mo/Cu center of carbon monoxide dehydrogenase from Oligotropha carboxidovorans.

    PubMed

    Wilcoxen, Jarett; Snider, Samantha; Hille, Russ

    2011-08-24

    Carbon monoxide dehydrogenase from Oligotropha carboxidovorans catalyzes the aerobic oxidation of carbon monoxide to carbon dioxide, providing the organism both a carbon source and energy for growth. The active site of the native enzyme is a unique binuclear molybdenum- and copper-containing center. Here we show that silver can be substituted for copper in the active site to yield a functional enzyme. The characteristic hyperfine coupling of the I = ½ nucleus of Ag is evident in the EPR signal of the binuclear active site observed upon reduction with CO, indicating both the incorporation of silver into the active site and, remarkably, retention of the catalytic activity. The silver-substituted enzyme is reduced by CO with an observed limiting rate constant of 8.1 s(-1), which can be compared with the value of 51 s(-1) for the wild-type enzyme. Steady-state kinetics for the Ag-substituted enzyme yielded k(cat) = 8.2 s(-1) and K(m) = 2.95 μM at pH 7.2.

  20. Production of carbon monoxide-free hydrogen and helium from a high-purity source

    DOEpatents

    Golden, Timothy Christopher; Farris, Thomas Stephen

    2008-11-18

    The invention provides vacuum swing adsorption processes that produce an essentially carbon monoxide-free hydrogen or helium gas stream from, respectively, a high-purity (e.g., pipeline grade) hydrogen or helium gas stream using one or two adsorber beds. By using physical adsorbents with high heats of nitrogen adsorption, intermediate heats of carbon monoxide adsorption, and low heats of hydrogen and helium adsorption, and by using vacuum purging and high feed stream pressures (e.g., pressures of as high as around 1,000 bar), pipeline grade hydrogen or helium can purified to produce essentially carbon monoxide -free hydrogen and helium, or carbon monoxide, nitrogen, and methane-free hydrogen and helium.

  1. Cobalt promoted copper manganese oxide catalysts for ambient temperature carbon monoxide oxidation.

    PubMed

    Jones, Christopher; Taylor, Stuart H; Burrows, Andrew; Crudace, Mandy J; Kiely, Christopher J; Hutchings, Graham J

    2008-04-14

    Low levels of cobalt doping (1 wt%) of copper manganese oxide enhances its activity for carbon monoxide oxidation under ambient conditions and the doped catalyst can display higher activity than current commercial catalysts.

  2. Investigation of low temperature carbon monoxide oxidation catalysts. [for Spacelab atmosphere control

    NASA Technical Reports Server (NTRS)

    Jagow, R. B.; Katan, T.; Ray, C. D.; Lamparter, R. A.

    1977-01-01

    Carbon monoxide generation rates related to the use of commerical equipment in Spacelab, added to the normal metabolic and subsystem loads, will produce carbon monoxide levels in excess of the maximum allowable concentration. In connection with the sensitivity of carbon monoxide oxidation catalysts to poisoning at room temperature, catalysts for an oxidation of carbon monoxide at low temperatures have been investigated. It was found that platinum and palladium are the only effective room temperature catalysts which are effective at 333 K. Hopcalite was ineffective at ambient temperatures, but converted CO with 100 percent efficiency at 333 K. Poisoning tests showed the noble metal catalysts to be very sensitive, and Hopcalite to be very resistant to poisoning.

  3. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection data base). Published Search

    SciTech Connect

    Not Available

    1992-08-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (Contains a minimum of 172 citations and includes a subject term index and title list.)

  4. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). Published Search

    SciTech Connect

    1996-10-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  5. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). Published Search

    SciTech Connect

    1995-10-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography.(Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  6. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). NewSearch

    SciTech Connect

    Not Available

    1994-10-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (Contains a minimum of 137 citations and includes a subject term index and title list.)

  7. Excess and unlike interaction second virial coefficients and excess enthalpy of mixing of (carbon monoxide + pentane)

    SciTech Connect

    McElroy, P.J.; Buchanan, S.

    1995-03-01

    Carbon monoxide and pentane are minor components of natural gas. The excess second virial coefficient of the mixture carbon monoxide + pentane has been determined at 299.5, 313.15, 328.15, and 343.15 K using the pressure change on mixing method. Unlike interaction second virial coefficients were derived and compared with the predictions of the Tsonopoulos correlation. The excess enthalpy of mixing was also estimated.

  8. A study of carbon monoxide distribution determinations for a global transport model

    NASA Technical Reports Server (NTRS)

    Peters, Leonard K.

    1988-01-01

    The primary objective of this grant was to further the development of a global transport/chemistry model that simulates the physico-chemical behavior of methane and carbon monoxide in the troposphere. The computer simulation model is designed to analyze the processes that occur as methane and carbon monoxide are transported from their respective sources to their ultimate fate, e.g., final conversion to CO2, transport to the stratosphere, deposition at ground level, etc.

  9. Reformer-pressure swing adsorption process for the production of carbon monoxide

    SciTech Connect

    Fuderer, A.

    1988-02-23

    An improved process for the production of carbon monoxide by the steam reforming of hydrocarbons is described comprising: (a) catalytically reacting a fluid hydrocarbon feed stream with steam in a steam reformer; (b) passing the reformer effluent containing hydrogen, carbon monoxide and carbon dioxide from the steam reformer, without scrubbing to remove the carbon dioxide content thereof, to a pressure swing adsorption system having at least four adsorbent beds, each bed of which, on a cyclic basis, undergoes a processing sequence; (c) recycling the carbon dioxide-rich stream to the steam reformer for reaction with additional quantities of the hydrocarbon feed stream being passed to the stream reformer to form additional quantities of carbon monoxide and hydrogen, with product recovery being enhanced and the need for employing a carbon dioxide wash system being obviated.

  10. Carbon Monoxide Epidemic Among Immigrant Populations: King County, Washington, 2006

    PubMed Central

    Kwan-Gett, Tao; Hampson, Neil B.; Baer, Atar; Shusterman, Dennis; Shandro, Jamie R.; Duchin, Jeffrey S.

    2009-01-01

    Objectives. We investigated an outbreak of carbon monoxide (CO) poisoning after a power outage to determine its extent, identify risk factors, and develop prevention measures. Methods. We reviewed medical records and medical examiner reports of patients with CO poisoning or related symptoms during December 15 to 24, 2006. We grouped patients into households exposed concurrently to a single source of CO. Results. Among 259 patients with CO poisoning, 204 cases were laboratory confirmed, 37 were probable, 10 were suspected, and 8 were fatal. Of 86 households studied, 58% (n = 50) were immigrant households from Africa (n = 21), Asia (n = 15), Latin America (n = 10), and the Middle East (n = 4); 34% (n = 29) were US-born households. One percent of households was European (n = 1), and the origin for 7% (n = 6) was unknown. Charcoal was the most common fuel source used among immigrant households (82%), whereas liquid fuel was predominant among US-born households (34%). Conclusions. Educational campaigns to prevent CO poisoning should consider immigrants’ cultural practices and languages and specifically warn against burning charcoal indoors and incorrect ventilation of gasoline- or propane-powered electric generators. PMID:19608962

  11. Carbon monoxide binding by hemoglobin and myoglobin under photodissociating conditions.

    PubMed

    Brunori, M; Bonaventura, J; Bonaventura, C; Antonini, E; Wyman, J

    1972-04-01

    Carbon monoxide binding by myoglobin and hemoglobin has been studied under conditions of constant illumination. For hemoglobin, the homotropic heme-heme interaction (cooperativity) and the heterotropic Bohr effect are invariant with light intensity over a 1000-fold change of c((1/2)). The dissociation constant, measured as c((1/2)), increases linearly with light intensity, indicating that photodissociation is a one-quantum process. At sufficiently high illumination the apparent enthalpy of ligand binding becomes positive, although in the absence of light it is known to be negative. This finding indicates that light acts primarily by increasing the "off" constants by an additive factor. The invariance of both cooperativity and Bohr effect raises a perplexing issue. It would appear to demand either that the "off" constants for the various elementary steps are all alike (which is contrary to current ideas) or that the additive factor is in each case proportional to the particular "off" constant to which it is added (a seemingly improbable alternative).

  12. Carbon monoxide and the CNS: challenges and achievements

    PubMed Central

    Queiroga, Cláudia S F; Vercelli, Alessandro; Vieira, Helena L A

    2015-01-01

    Haem oxygenase (HO) and its product carbon monoxide (CO) are associated with cytoprotection and maintenance of homeostasis in several different organs and tissues. This review focuses upon the role of exogenous and endogenous CO (via HO activity and expression) in various CNS pathologies, based upon data from experimental models, as well as from some clinical data on human patients. The pathophysiological conditions reviewed are cerebral ischaemia, chronic neurodegenerative diseases (Alzheimer's and Parkinson's diseases), multiple sclerosis and pain. Among these pathophysiological conditions, a variety of cellular mechanisms and processes are considered, namely cytoprotection, cell death, inflammation, cell metabolism, cellular redox responses and vasomodulation, as well as the different targeted neural cells. Finally, novel potential methods and strategies for delivering exogenous CO as a drug are discussed, particularly approaches based upon CO-releasing molecules, their limitations and challenges. The diagnostic and prognostic value of HO expression in clinical use for brain pathologies is also addressed. Linked Articles This article is part of a themed section on Pharmacology of the Gasotransmitters. To view the other articles in this section visit http://dx.doi.org/10.1111/bph.2015.172.issue-6 PMID:24758548

  13. The neurotoxicology of carbon monoxide - Historical perspective and review.

    PubMed

    Sykes, Oliver T; Walker, Edward

    2016-01-01

    Carbon monoxide (CO) has been recognized as a poison for centuries, and remains one of the most common causes of both accidental and deliberate poisoning worldwide. Despite this, there are widespread misconceptions with regards to the mechanisms, diagnosis and outcomes of CO induced poisoning such as the idea that CO poisoning is rare; that carboxyhaemoglobin levels above 20% and loss of consciousness are required before nervous system damage ensues; and that the binding of CO to haemoglobin is the only mechanism of toxicity. Prevention and diagnosis of CO poisoning is hampered by the lack of awareness of CO as a cause of illness, among both the general public and healthcare professionals. To complicate matters further there is no standardized definition of CO poisoning. Carboxyhaemoglobin levels are often used as a marker of CO poisoning, yet plasma levels rapidly reduce upon removal of the source and are therefore an unreliable biomarker of exposure and tissue damage. Adverse neuropsychiatric outcomes after CO poisoning are difficult to define, especially as they fluctuate, mimic other non-specific complaints, and are not present in all survivors. This paper challenges a number of misconceptions about CO poisoning which can result in misdiagnosis, and consequently in mismanagement. We illustrate how recent developments in the understanding of CO toxicology explain the particular susceptibility of the central nervous system to the effects of CO exposure.

  14. A Wireless and Batteryless Intelligent Carbon Monoxide Sensor.

    PubMed

    Chen, Chen-Chia; Sung, Gang-Neng; Chen, Wen-Ching; Kuo, Chih-Ting; Chue, Jin-Ju; Wu, Chieh-Ming; Huang, Chun-Ming

    2016-09-23

    Carbon monoxide (CO) poisoning from natural gas water heaters is a common household accident in Taiwan. We propose a wireless and batteryless intelligent CO sensor for improving the safety of operating natural gas water heaters. A micro-hydropower generator supplies power to a CO sensor without battery (COSWOB) (2.5 W at a flow rate of 4.2 L/min), and the power consumption of the COSWOB is only ~13 mW. The COSWOB monitors the CO concentration in ambient conditions around natural gas water heaters and transmits it to an intelligent gateway. When the CO level reaches a dangerous level, the COSWOB alarm sounds loudly. Meanwhile, the intelligent gateway also sends a trigger to activate Wi-Fi alarms and sends notifications to the mobile device through the Internet. Our strategy can warn people indoors and outdoors, thereby reducing CO poisoning accidents. We also believe that our technique not only can be used for home security but also can be used in industrial applications (for example, to monitor leak occurrence in a pipeline).

  15. Carbon monoxide exposures after hurricane Ike - Texas, September 2008.

    PubMed

    2009-08-14

    During power outages after hurricanes, survivors can be at risk for carbon monoxide (CO) poisoning if they use portable generators improperly. On September 13, 2008, Hurricane Ike struck the coast of Texas, leaving approximately 2.3 million households in the southeastern portion of the state without electricity. Six days later, 1.3 million homes were still without electrical power. To assess the impact of storm-related CO exposures and to enhance prevention efforts, CDC analyzed data from five disparate surveillance sources on CO exposures reported during September 13--26 in counties of southeast Texas that were declared disaster areas by the federal government. This report describes the results of that analysis, which indicated that one data source, Texas poison centers, received reports of 54 persons with storm-related CO exposures during the surveillance period. Another data source, the Undersea and Hyperbaric Medical Society (UHMS) hyperbaric oxygen treatment database, reported that 15 persons received hyperbaric oxygen treatment for storm-related CO poisoning. Medical examiners, public health officials, and hospitals in Texas reported that seven persons died from storm-related CO poisoning. Among the data sources, the percentage of reported storm-related CO exposures caused by improper generator use ranged from 82% to 87%. These findings underscore the need for effective prevention messages during storm preparation, warnings, and response periods regarding the correct use of generators and the installation and maintenance of battery-powered CO detectors.

  16. Modeling carbon monoxide spread in underground mine fires

    PubMed Central

    Yuan, Liming; Zhou, Lihong; Smith, Alex C.

    2016-01-01

    Carbon monoxide (CO) poisoning is a leading cause of mine fire fatalities in underground mines. To reduce the hazard of CO poisoning in underground mines, it is important to accurately predict the spread of CO in underground mine entries when a fire occurs. This paper presents a study on modeling CO spread in underground mine fires using both the Fire Dynamics Simulator (FDS) and the MFIRE programs. The FDS model simulating part of the mine ventilation network was calibrated using CO concentration data from full-scale mine fire tests. The model was then used to investigate the effect of airflow leakage on CO concentration reduction in the mine entries. The inflow of fresh air at the leakage location was found to cause significant CO reduction. MFIRE simulation was conducted to predict the CO spread in the entire mine ventilation network using both a constant heat release rate and a dynamic fire source created from FDS. The results from both FDS and MFIRE simulations are compared and the implications of the improved MFIRE capability are discussed. PMID:27069400

  17. Carbon monoxide exchange and partitioning of a managed mountain meadow

    NASA Astrophysics Data System (ADS)

    Wohlfahrt, G.; Hammerle, A.; Kitz, F.; Spielmann, F.

    2015-12-01

    With an average mole fraction of 100 ppb carbon monoxide (CO) plays a critical role in atmospheric chemistry and thus has an indirect global warming potential. While sources/sinks of CO on land at least partially cancel out each other, the magnitude of CO sources and sinks is highly uncertain. Even if direct CO fluxes from/to land ecosystems are very much likely clearly lower in magnitude compared to anthropogenic emissions, biomass burning, emissions from chemical precursors and the OH sink, it may be premature to neglect any direct contributions of land ecosystems to the CO budget. In addition, changes in global climate and resulting changes in global productivity may require re-evaluating older data and assumptions. One major reason for the large uncertainty is a general scarcity of empirical data. An additional factor contributing to the uncertainty is the lack of ecosystem-scale CO exchange measurements, i.e. CO flux data that encompass all sources and sinks within an ecosystem. Here we present data on continuous eddy covariance measurements of CO-fluxes above a managed mountain grassland in combination with soil chamber flux measurements, within- and above-canopy concentration profiles and an inverse Lagrangian analysis to disentangle sinks and sources of CO. Preliminary results show the grassland ecosystem to be a net source for CO during daytime, with increasing flux rates at higher solar radiation. At night, if at all, the meadow is a slight sink for CO. The same holds true for soil flux measurements.

  18. Physiological activities of carbon monoxide-releasing molecules: Ca ira.

    PubMed

    Chatterjee, P K

    2007-04-01

    In this issue of British Journal of Pharmacology, Megías and colleagues demonstrate how preincubation of human colonic Caco-2 cells with CORM-2, a carbon monoxide releasing molecule (CO-RM), reduces the expression of inducible nitric oxide synthase, interleukin (IL)-6 and IL-8 caused by proinflammatory cytokines. A role for IL-6 in the regulation of metalloproteinase (MMP)-7 expression by CORM-2 is described. However, it is the demonstration that CORM-2 inhibits MMP-7 or matrilysin expression, which is most intriguing as this small MMP has been implicated in carcinogenesis. Thus, CO-RMs appear to now possess chemoprotective properties and, in this particular case, may influence inflammation-induced colon carcinogenesis via modulation of nuclear factors participating in the transcription of genes implicated in the development of intestinal inflammation and cancer. This report opens yet another door for research involving these exciting molecules and it is now clear that further discoveries of the beneficial properties of CO-RMs will go on.

  19. In-utero carbon monoxide poisoning and multiple fetal abnormalities

    SciTech Connect

    Hennequin, Y.; Blum, D.; Vamos, E.; Steppe, M.; Goedseels, J.; Cavatorta, E. . Queen Fabiola Children's Hospital)

    1993-01-23

    Carbon monoxide (CO) poisoning during pregnancy can lead to feto-maternal fatalities and stillbirths. Teratogenic effects have been reported. The authors strongly suspected an association between mild but chronic CO poisoning of the mother and major multiple malformations in the baby. Retrospective interviews of the mother disclosed that at 10 weeks' gestation, she had complained of headache and dizziness. At the same time, her 16-month-old daughter had an episode of unconsciousness. A faulty kitchen gas water-heater was suspected but the family did not have it repaired. The mother continued to have headaches regularly. During the 7th month of pregnancy, the daughter was found comatose. In the emergency ward, carboxyhemoglobins levels were 27.5% for the child and 14% for the pregnant mother. Both were treated with hyperbaric oxygen. Investigations by the gas company revealed a highly abnormal CO production from the kitchen and bathroom gas-water heaters: 120 and 100 parts per million, respectively, after 2 minutes of use.

  20. Carbon Monoxide in Exhaled Breath Testing and Therapeutics

    PubMed Central

    Ryter, Stefan W.; Choi, Augustine M.K.

    2013-01-01

    Carbon monoxide (CO), a low molecular weight gas, is a ubiquitous environmental product of organic combustion, which is also produced endogenously in the body, as the byproduct of heme metabolism. CO binds to hemoglobin, resulting in decreased oxygen delivery to bodily tissues at toxicological concentrations. At physiological concentrations, CO may have endogenous roles as a potential signaling mediator in vascular function and cellular homeostasis. Exhaled CO (eCO), similar to exhaled nitric oxide (eNO), has been evaluated as a candidate breath biomarker of pathophysiological states, including smoking status, and inflammatory diseases of the lung and other organs. eCO values have been evaluated as potential indicators of inflammation in asthma, stable COPD and exacerbations, cystic fibrosis, lung cancer, or during surgery or critical care. The utility of eCO as a marker of inflammation, and potential diagnostic value remains incompletely characterized. Among other candidate “medicinal gases” with therapeutic potential, (e.g., NO and H2S), CO has been shown to act as an effective anti-inflammatory agent in preclinical animal models of inflammatory disease, acute lung injury, sepsis, ischemia/reperfusion injury and organ graft rejection. Current and future clinical trials will evaluate the clinical applicability of this gas as a biomarker and/or therapeutic in human disease. PMID:23446063

  1. Occupational carbon monoxide poisoning in Washington State, 2000-2005.

    PubMed

    Reeb-Whitaker, Carolyn K; Bonauto, David K; Whittaker, Stephen G; Adams, Darrin

    2010-10-01

    Washington State workers' compensation data can be used to guide prevention efforts focused on occupational carbon monoxide (CO) poisoning. Between 2000 and 2005, a total of 345 individual claims comprising 221 different exposure incidents were identified for the 6-year time period. The construction industry had 43 (20%) CO incidents, followed by wholesale trade with 32 (15%), and agriculture with 27 (12%) incidents. Fuel-powered forklifts caused 29% of all incidents, while autos/trucks/buses were responsible for 26%. The number of forklift incidents in fruit packing and cold storage companies declined significantly from 1994 through 2007 (Spearman's rho = 0.6659, p < 0.01). While this study used multiple medical records from workers' compensation claims to identify CO poisoning, a surveillance system that lacks extensive medical records may rely principally on carboxyhemoglobin (COHb) tests. This study demonstrated that 71% of the identified workers' compensation claims had associated COHb tests. The recurrence and timing of CO poisoning as well as control of the CO-generating source were determined. Approximately 8% of all work sites had recurring CO poisoning incidents. Two percent experienced a recurrent incident within 16 days of the initial incident, and 6% experienced a recurrent incident between 16 days and 3 years after the initial incident. Sixty-seven percent of claimants exposed to CO were not in direct control of the CO-generating source; this has implications for CO prevention and underscores the need for all employees to be trained on CO hazards.

  2. Simulation of carbon monoxide transport during April 1994

    NASA Astrophysics Data System (ADS)

    Faluvegi, G. S.; Alapaty, K.; Reichle, H. G.; Mathur, R.; Raman, S.; Connors, V. S.

    1999-09-01

    The Multiscale Air Quality Simulation Platform (MAQSIP) is used to simulate transport of carbon monoxide (CO) as a passive tracer over North America, Europe, and the North Atlantic during the April 1994 Measurement of Air Pollution from Satellites (MAPS) mission. MAQSIP is driven by meteorological fields generated by the Pennsylvania State University/National Center for Atmospheric Research fifth-generation mesoscale model. Model CO surface emissions from biomass burning, fossil fuel combustion, nonmethane hydrocarbon oxidation, oceans, and soils are based on inventories from the Belgian Institute for Space Aeronomy and the Global Emissions Inventory Activity. Predicted CO mixing ratios are vertically weighted for comparison with MAPS observations. The spread in the mission-averaged vertically weighted simulated CO mixing ratios (˜38 ppbv, compared to 60 ppbv in the MAPS data) suggests that CO surface emissions significantly affect MAPS observations on a weekly timescale. Good qualitative agreement is found between MAPS observations and model predictions on several temporal and spatial scales. Possible reasons for discrepancies are examined. A simulation without cumulus convection increases CO mixing ratios in the lower model layers and depletes CO above, resulting in a complex pattern of increases and decreases upon vertical weighted integration. Another simulation, which included a diurnal emissions variation, produced significant changes in instantaneous local CO mixing ratios, but had a minimal effect on the mission-averaged MAPS comparisons.

  3. Heme oxygenase-1/carbon monoxide: from metabolism to molecular therapy.

    PubMed

    Ryter, Stefan W; Choi, Augustine M K

    2009-09-01

    Heme oxygenase-1 (HO-1), a ubiquitous inducible stress-response protein, serves a major metabolic function in heme turnover. HO activity cleaves heme to form biliverdin-IXalpha, carbon monoxide (CO), and iron. Genetic experiments have revealed a central role for HO-1 in tissue homeostasis, protection against oxidative stress, and in the pathogenesis of disease. Four decades of research have witnessed not only progress in elucidating the molecular mechanisms underlying the regulation and function of this illustrious enzyme, but also have opened remarkable translational applications for HO-1 and its reaction products. CO, once regarded as a metabolic waste, can act as an endogenous mediator of cellular signaling and vascular function. Exogenous application of CO by inhalation or pharmacologic delivery can confer cytoprotection in preclinical models of lung/vascular injury and disease, based on anti-apoptotic, anti-inflammatory, and anti-proliferative properties. The bile pigments, biliverdin and bilirubin, end products of heme degradation, have also shown potential as therapeutics in vascular disease based on anti-inflammatory and anti-proliferative activities. Further translational and clinical trials research will unveil whether the HO-1 system or any of its reaction products can be successfully applied as molecular medicine in human disease.

  4. Carbon monoxide inhalation increases microparticles causing vascular and CNS dysfunction.

    PubMed

    Xu, Jiajun; Yang, Ming; Kosterin, Paul; Salzberg, Brian M; Milovanova, Tatyana N; Bhopale, Veena M; Thom, Stephen R

    2013-12-01

    We hypothesized that circulating microparticles (MPs) play a role in pro-inflammatory effects associated with carbon monoxide (CO) inhalation. Mice exposed for 1h to 100 ppm CO or more exhibit increases in circulating MPs derived from a variety of vascular cells as well as neutrophil activation. Tissue injury was quantified as 2000 kDa dextran leakage from vessels and as neutrophil sequestration in the brain and skeletal muscle; and central nervous system nerve dysfunction was documented as broadening of the neurohypophysial action potential (AP). Indices of injury occurred following exposures to 1000 ppm for 1h or to 1000 ppm for 40 min followed by 3000 ppm for 20 min. MPs were implicated in causing injuries because infusing the surfactant MP lytic agent, polyethylene glycol telomere B (PEGtB) abrogated elevations in MPs, vascular leak, neutrophil sequestration and AP prolongation. These manifestations of tissue injury also did not occur in mice lacking myeloperoxidase. Vascular leakage and AP prolongation were produced in naïve mice infused with MPs that had been obtained from CO poisoned mice, but this did not occur with MPs obtained from control mice. We conclude that CO poisoning triggers elevations of MPs that activate neutrophils which subsequently cause tissue injuries.

  5. Hydrogen or carbon monoxide in the liquefaction of biomass

    SciTech Connect

    Davis, H.; Figueroa, C.; Schaleger, L.

    1982-02-01

    The bench-scale continuous biomass liquefaction unit, in operation at Lawrence Berkeley Laboratory (LBL), is described. The feedstock is an aqueous slurry of partially hydrolyzed Douglas fir wood, but extension to other biomass types and peat is planned. The process has previously used carbon monoxide as reducing gas. Under the condtions employed at LBL, 330/sup 0/ to 360/sup 0/C, 200 to 270 BAR in an atmosphere of steam and reducing gas, no recycle, little or no reducing gas is consumed and it has been shown that hydrogen can be used as the reactant gas. Since large amounts of CO react by the water gas shift reaction, substitution of hydrogen gives a substantial economic advantage. It also opens the possibility of incorporating hydrogenation catalysts and integrating the liquefaction step with separate hydrocracking of crude product. Yields and products are compared with those from the oil-recycle or PERC process. The water slurry process makes less of the desired crude wood-oil product (30 to 40 vs 45 to 55 wt %) and more water soluble organics (about 25 vs. about 8 wt %). However, the most operationally successful PERC operations have achieved this product distribution at the expense of extremely high oil and water recycle and large CO consumption.

  6. A Wireless and Batteryless Intelligent Carbon Monoxide Sensor

    PubMed Central

    Chen, Chen-Chia; Sung, Gang-Neng; Chen, Wen-Ching; Kuo, Chih-Ting; Chue, Jin-Ju; Wu, Chieh-Ming; Huang, Chun-Ming

    2016-01-01

    Carbon monoxide (CO) poisoning from natural gas water heaters is a common household accident in Taiwan. We propose a wireless and batteryless intelligent CO sensor for improving the safety of operating natural gas water heaters. A micro-hydropower generator supplies power to a CO sensor without battery (COSWOB) (2.5 W at a flow rate of 4.2 L/min), and the power consumption of the COSWOB is only ~13 mW. The COSWOB monitors the CO concentration in ambient conditions around natural gas water heaters and transmits it to an intelligent gateway. When the CO level reaches a dangerous level, the COSWOB alarm sounds loudly. Meanwhile, the intelligent gateway also sends a trigger to activate Wi-Fi alarms and sends notifications to the mobile device through the Internet. Our strategy can warn people indoors and outdoors, thereby reducing CO poisoning accidents. We also believe that our technique not only can be used for home security but also can be used in industrial applications (for example, to monitor leak occurrence in a pipeline). PMID:27669255

  7. Carbon monoxide observed in Venus' atmosphere with SOIR/VEx

    NASA Astrophysics Data System (ADS)

    Vandaele, A. C.; Mahieux, A.; Chamberlain, S.; Ristic, B.; Robert, S.; Thomas, I. R.; Trompet, L.; Wilquet, V.; Bertaux, J. L.

    2016-07-01

    The SOIR instrument on board the ESA Venus Express mission has been operational during the complete duration of the mission, from April 2006 up to December 2014. Spectra were recorded in the IR spectral region (2.2-4.3 μm) using the solar occultation geometry, giving access to a vast number of ro-vibrational lines and bands of several key species of the atmosphere of Venus. Here we present the complete set of vertical profiles of carbon monoxide (CO) densities and volume mixing ratios (vmr) obtained during the mission. These profiles are spanning the 65-150 km altitude range. We discuss the variability which is observed on the short term, but also the long term trend as well as variation of CO with solar local time and latitude. Short term variations can reach one order of magnitude on less than one month periods. SOIR does not observe a marked long term trend, except perhaps at the beginning of the mission where an increase of CO density and vmr has been observed. Evening abundances are systematically higher than morning values at altitudes above 105 km, but the reverse is observed at lower altitudes. Higher abundances are observed at the equator than at the poles for altitude higher than 105 km, but again the reverse is seen at altitudes lower than 90 km. This illustrates the complexity of the 90-100 km region of the Venus' atmosphere where different wind regimes are at play.

  8. Effect of water on carbon monoxide-oxygen flame velocity

    NASA Technical Reports Server (NTRS)

    Mcdonald, Glen E

    1954-01-01

    The flame velocities were measured of 20 percent oxygen and 80 percent carbon monoxide mixtures containing either light water or heavy water. The flame velocity increased from 34.5 centimeters per second with no added water to about 104 centimeters per second for a 1.8 percent addition of light water and to 84 centimeters per second for an equal addition of heavy water. The addition of heavy water caused greater increases in flame velocity with equilibrium hydrogen-atom concentration than would be predicted by the Tanford and Pease square-root relation. The ratio of the flame velocity of a mixture containing light water to that of a mixture containing heavy water was found to be 1.4. This value is the same as the ratio of the reaction rate of hydrogen to that of deuterium and oxygen. A ratio of reaction rates of 1.4 would also be required for the square-root law to give the observed ratio of flame-velocity changes.

  9. Stability of blood carbon monoxide and hemoglobins during heating.

    PubMed

    Seto, Y; Kataoka, M; Tsuge, K

    2001-09-15

    The effects of heating on hemoglobin (Hb) and carbon monoxide (CO) levels in human blood were investigated by in vitro experiments. Head-space gas chromatography (HS-GC) using a molecular sieve 5A stationary phase and thermal conductivity detection was adopted for the measurement of CO gas, and spectrophotometric methods were used for the measurement of various Hb forms, protein and heme contents. Deteriorated absorbance spectra were observed for heat-treated blood samples, and double wavelength spectrophotometry was proven to give wrong percent saturation of carboxyhemoglobin content (% CO-Hb). The blood sample taken from one fatal fire casualty gave significantly higher % CO-Hb measured spectrophotometrically, compared to that by HS-GC. Control blood or purified Hb solution, which was saturated with CO in designated extent, was heated in a sealed vial. Under the incubation below 54 degrees C, all Hb forms were stable, except for oxyhemoglobin (Hb-O(2)), which was partially oxidized to met-hemoglobin (Met-Hb). In contrast, under the incubation at 65 degrees C, Met-Hb was denatured completely to be insoluble, and Hb-O(2) was partially denatured via Met-Hb formation. CO-Hb was resistant against heating. The difference of heat susceptibility and precipitability among Hb forms resulted in artificial increase of % CO-Hb. During heating, spontaneous CO was produced from blood.

  10. Carbon monoxide: an emerging regulator of ion channels.

    PubMed

    Wilkinson, William J; Kemp, Paul J

    2011-07-01

    Carbon monoxide is rapidly emerging as an important cellular messenger, regulating a wide range of physiological processes. Crucial to its role in both physiology and disease is its ability differentially to regulate several classes of ion channels, including examples from calcium-activated K(+) (BK(Ca)), voltage-activated K(+) (K(v)) and Ca(2+) channel (L-type) families, ligand-gated P2X receptors (P2X2 and P2X4), tandem P domain K(+) channels (TREK1) and the epithelial Na(+) channel (ENaC). The mechanisms by which CO regulates these ion channels are still unclear and remain somewhat controversial. However, available structure-function studies suggest that a limited range of amino acid residues confer CO sensitivity, either directly or indirectly, to particular ion channels and that cellular redox state appears to be important to the final integrated response. Whatever the molecular mechanism by which CO regulates ion channels, endogenous production of this gasotransmitter has physiologically important roles and is currently being explored as a potential therapeutic.

  11. Carbon monoxide exposure in households in Ciudad Juárez, México.

    PubMed

    Montoya, Teresa; Gurian, Patrick L; Velázquez-Angulo, Gilberto; Corella-Barud, Verónica; Rojo, Analila; Graham, Jay P

    2008-03-01

    This study assessed exposure to carbon monoxide from gas and wood heater emissions in a sample of 64 households in peri-urban residential areas in Ciudad Juárez, Chihuahua, México. Indoor and outdoor carbon monoxide concentrations and temperatures were monitored for a continuous period of 1 week at 1 and 6-min intervals, respectively. The moving average carbon monoxide concentrations were compared to the World Health Organization (WHO) standards for carbon monoxide. Sixty-seven percent of households with gas heaters and 60% of households with wood heaters exceeded a health-based standard at some point during the monitoring. The difference between indoor and outdoor temperatures was modestly correlated with average carbon monoxide exposure (r=0.35, p-value <0.01). Heater type may be a stronger determinant of exposure, as households with a particular heater model (the El Sol FM-210) were significantly more likely to be among the more highly exposed households (odds ratio of 4.8, p-value of 0.02). A variety of health effects were pooled and found at elevated frequency in the households that exceeded the 8-h standard of 9ppm (odds ratio=5.1, p-value=0.031). These results highlight the need for further efforts to identify and mitigate potentially hazardous carbon monoxide exposures, particularly in moderate-income countries with cooler climates.

  12. Chemisorption on surfaces — an historical look at a representative adsorbate: carbon monoxide

    NASA Astrophysics Data System (ADS)

    Yates, John T.

    1994-01-01

    The study of the interaction of molecules with clean surfaces extends back to the work of Irving Langmuir. In this historical account, the development of selected experimental methods for the study of molecular adsorption will be discussed. This will be done by historically reviewing research on one of the most well-studied adsorbate molecules, carbon monoxide. Many of the modern surface science techniques have first been used to study chemisorbed carbon monoxide, and the CO molecule is employed even today as a test molecule for currently developing surface measurement instruments such as the low temperature STM. In addition to being a good test molecule for new surface measurement techniques, adsorbed carbon monoxide is one of the centrally important molecules in the field of heterogeneous catalysis where the production of synthetic fuels and useful organic molecules often depends on the catalytic behavior of the adsorbed CO molecule. Interestingly, the carbon monoxide molecule also serves as a bridge between surface chemistry on the transition metals and the field of organometallic chemistry. Concepts about the chemical bonding and the reactive behavior of CO chemisorbed on transition metal surfaces and CO bound in transition metal carbonyls link these two fields together in a significant manner. The carbon monoxide molecule has been the historical focal point of many endeavors in surface chemistry and surface physics, and research on adsorbed carbon monoxide well represents many of the key advances which characterize the first thirty years of the development of surface science.

  13. Solar carbon monoxide: poster child for 3D effects .

    NASA Astrophysics Data System (ADS)

    Ayres, T. R.; Lyons, J. R.; Ludwig, H.-G.; Caffau, E.; Wedemeyer-Böhm, S.

    Photospheric infrared (2-6 mu m) rovibrational bands of carbon monoxide (CO) provide a tough test for 3D convection models such as those calculated using CO5BOLD. The molecular formation is highly temperature-sensitive, and thus responds in an exaggerated way to thermal fluctuations in the dynamic atmosphere. CO, itself, is an important tracer of the oxygen abundance, a still controversial issue in solar physics; as well as the heavy isotopes of carbon (13C) and oxygen (18O, 17O), which, relative to terrestrial values, are fingerprints of fractionation processes that operated in the primitive solar nebula. We show how 3D models impact the CO line formation, and add in a second constraint involving the near-UV Ca RIPTSIZE II line wings, which also are highly temperature sensitive, but in the opposite sense to the molecules. We find that our reference CO5BOLD snapshots appear to be slightly too cool on average in the outer layers of the photosphere where the CO absorptions and Ca RIPTSIZE II wing emissions arise. We show, further, that previous 1D modeling was systematically biased toward higher oxygen abundances and lower isotopic ratios (e.g., R23equiv 12C/13C), suggesting an isotopically ``heavy'' Sun contrary to direct capture measurements of solar wind light ions by the Genesis Discovery Mission. New 3D ratios for the oxygen isotopes are much closer to those reported by Genesis, and the associated oxygen abundance from CO now is consistent with the recent Caffau et al. study of atomic oxygen. Some lingering discrepancies perhaps can be explained by magnetic bright points. Solar CO demonstrates graphically the wide gulf that can occur between a 3D analysis and 1D.

  14. Carbon monoxide in indoor ice skating rinks: Evaluation of absorption by adult hockey players

    SciTech Connect

    Levesque, B.; Dewailly, E.; Lavoie, R.; Prud'Homme, D.; Allaire, S. )

    1990-05-01

    We evaluated alveolar carbon monoxide (CO) levels of 122 male, adult hockey players active in recreational leagues of the Quebec City region (Canada), before and after 10 weekly 90-minute games in 10 different rinks. We also determined exposure by quantifying the average CO level in the rink during the games. Other variables documented included age, pulmonary function, aerobic capacity, and smoking status. Environmental concentrations varied from 1.6 to 131.5 parts per million (ppm). We examined the absorption/exposure relationship using a simple linear regression model. In low CO exposure levels, physical exercise lowered the alveolar CO concentration. However, we noted that for each 10 ppm of CO in the ambient air, the players had adsorbed enough CO to raise their carboxyhemoglobin (COHb) levels by 1 percent. This relationship was true both for smokers and non-smokers. We suggest that an average environmental concentration of 20 ppm of CO for the duration of a hockey game (90 minutes) should be reference limit not to be exceeded in indoor skating rinks.

  15. Molecular Analysis of Carbon Monoxide-Oxidizing Bacteria Associated with Recent Hawaiian Volcanic Deposits†

    PubMed Central

    Dunfield, Kari E.; King, Gary M.

    2004-01-01

    Genomic DNA extracts from four sites at Kilauea Volcano were used as templates for PCR amplification of the large subunit (coxL) of aerobic carbon monoxide dehydrogenase. The sites included a 42-year-old tephra deposit, a 108-year-old lava flow, a 212-year-old partially vegetated ash-and-tephra deposit, and an approximately 300-year-old forest. PCR primers amplified coxL sequences from the OMP clade of CO oxidizers, which includes isolates such as Oligotropha carboxidovorans, Mycobacterium tuberculosis, and Pseudomonas thermocarboxydovorans. PCR products were used to create clone libraries that provide the first insights into the diversity and phylogenetic affiliations of CO oxidizers in situ. On the basis of phylogenetic and statistical analyses, clone libraries for each site were distinct. Although some clone sequences were similar to coxL sequences from known organisms, many sequences appeared to represent phylogenetic lineages not previously known to harbor CO oxidizers. On the basis of average nucleotide diversity and average pairwise difference, a forested site supported the most diverse CO-oxidizing populations, while an 1894 lava flow supported the least diverse populations. Neither parameter correlated with previous estimates of atmospheric CO uptake rates, but both parameters correlated positively with estimates of microbial biomass and respiration. Collectively, the results indicate that the CO oxidizer functional group associated with recent volcanic deposits of the remote Hawaiian Islands contains substantial and previously unsuspected diversity. PMID:15240307

  16. Molecular analysis of carbon monoxide-oxidizing bacteria associated with recent Hawaiian volcanic deposits.

    PubMed

    Dunfield, Kari E; King, Gary M

    2004-07-01

    Genomic DNA extracts from four sites at Kilauea Volcano were used as templates for PCR amplification of the large subunit (coxL) of aerobic carbon monoxide dehydrogenase. The sites included a 42-year-old tephra deposit, a 108-year-old lava flow, a 212-year-old partially vegetated ash-and-tephra deposit, and an approximately 300-year-old forest. PCR primers amplified coxL sequences from the OMP clade of CO oxidizers, which includes isolates such as Oligotropha carboxidovorans, Mycobacterium tuberculosis, and Pseudomonas thermocarboxydovorans. PCR products were used to create clone libraries that provide the first insights into the diversity and phylogenetic affiliations of CO oxidizers in situ. On the basis of phylogenetic and statistical analyses, clone libraries for each site were distinct. Although some clone sequences were similar to coxL sequences from known organisms, many sequences appeared to represent phylogenetic lineages not previously known to harbor CO oxidizers. On the basis of average nucleotide diversity and average pairwise difference, a forested site supported the most diverse CO-oxidizing populations, while an 1894 lava flow supported the least diverse populations. Neither parameter correlated with previous estimates of atmospheric CO uptake rates, but both parameters correlated positively with estimates of microbial biomass and respiration. Collectively, the results indicate that the CO oxidizer functional group associated with recent volcanic deposits of the remote Hawaiian Islands contains substantial and previously unsuspected diversity.

  17. Carbon monoxide oxidation by bacteria associated with the roots of freshwater macrophytes

    SciTech Connect

    Rich, J.J.; King, G.M.

    1998-12-01

    The potential rates and control of aerobic root-associated carbon monoxide (CO) consumption were assessed by using excised plant roots from five common freshwater macrophytes. Kinetic analyses indicated that the maximum potential uptake velocities for CO consumption ranged from 0.4 to 2.7 {micro}mol of CO g (dry weight){sup {minus}1} h{sup {minus}1} for the five species. The observed rates were comparable to previously reported rates of root-associated methane uptake. The apparent half-saturation constants for CO consumption ranged from 50 to 370 nM CO; these values are considerably lower than the values obtained for methane uptake. The CO consumption rates reached maximum values at temperatures between 27 and 32 C, and there was a transition to CO production at {ge}44 C, most likely as a result of thermochemical organic matter decomposition. Incubation of roots with organic substrates dramatically reduced the rate of CO consumption, perhaps reflecting a shift in metabolism by facultative CO oxidizers. Based on responses to a suite of antibiotics, most of the CO consumption was due to eubacteria rather than fungi or other eucaryotes. Based on the results of acetylene inhibition experiments, methanotrophs and ammonia oxidizers were not active CO consumers.

  18. Separation of Carbon Monoxide and Carbon Dioxide for Mars ISRU-Concepts

    NASA Technical Reports Server (NTRS)

    LeVan, M. Douglas; Finn, John E.; Sridhar, K. R.

    2000-01-01

    Solid oxide electrolyzers, such as electrolysis cells utilizing yttria-stabilized zirconia, can produce oxygen from Mars atmospheric carbon dioxide and reject carbon monoxide and unreacted carbon dioxide in a separate stream. The oxygen-production process has been shown to be far more efficient if the high-pressure, unreacted carbon dioxide can be separated and recycled back into the feed stream. Additionally, the mass of the adsorption compressor can be reduced. Also, the carbon monoxide by-product is a valuable fuel for space exploration and habitation, with applications from fuel cells to production of hydrocarbons and plastics. In our research, we will design, construct, and test an innovative, robust, low mass, low power separation device that can recover carbon dioxide and carbon monoxide for Mars ISRU. Such fundamental process technology, involving gas-solid phase separation in a reduced gravitational environment, will help to enable Human Exploration and Development of Space. The separation device will be scaled to operate with a CO2 sorption compressor and a zirconia electrolysis device built at the NASA Ames Research Center and the University of Arizona, respectively. In our research, we will design, construct, and test an innovative, robust, low mass, low power separation device that can recover carbon dioxide and carbon monoxide for Mars ISRU, Such fundamental process technology, involving gas-solid phase separation in a reduced gravitational environment, will help to enable Human Exploration and Development of Space. The separation device will be scaled to operate with a CO2 sorption compressor and a zirconia electrolysis device built at the NASA Ames Research Center and the University of Arizona, The separation device will be scaled to operate with a CO2 sorption compressor and a zirconia electrolysis device built at the NASA Ames Research Center and the University of Arizona, Research needs for the design shown are as follows: (1) The best adsorbent

  19. The isotopic characterization of carbon monoxide in the troposphere

    NASA Astrophysics Data System (ADS)

    Conny, Joseph M.

    The distributions of stable isotopes in trace atmospheric species are controlled mainly by the isotopic compositions of precursor molecules and isotope fractionation effects during production and removal of the species. Distributions of radioactive isotopes are controlled mainly by the isotopic compositions of precursor molecules and radioactive decay processes. As a result, through their isotopic compositions, atmospheric species are traceable to sources and sinks. Thus, isotopic compositions provide useful information for estimating source strengths and for understanding the importance of removal processes in the cycling of the species. The use of radioactive 14C and the stable isotopes ( 13C and 18O) are reviewed here for understanding production and removal processes of CO in the troposphere. Carbon monoxide is a critical component in atmospheric chemistry because of its large effect on levels of OH, the principal oxidant in the atmosphere. In the troposphere, this is due to relatively high concentrations of CO and a short lifetime (2-4 months). Initially, 14CO measurements were instrumental in estimating accurately the tropospheric lifetime. Since seasonal 14CO variation is controlled largely by OH, 14CO serves as an important surrogate measure of tropospheric OH. Global 14CO measurements have also been used to estimate the biogenic component of the global CO budget, specifically contributions from biomass burning, oxidized non-methane hydrocarbon (NMHC) emissions, oceans and plants. Research using 14CO measurements is also active in quantifying fossil and non-fossil urban emissions. Kinetic isotopic fractionation during production of 13CO and C 18O from reduced precursors allows one to distinguish, at least qualitatively, different varieties of CO based on seasonal tropospheric isotopic measurements. Difficulties in interpreting the stable isotopic record arise from large fractionation effects that obscure source isotopic signatures (in particular the oxygen

  20. Complex maze performance during carbon monoxide exposure in rats.

    PubMed

    Annau, Z

    1987-01-01

    Most human victims of residential fires die of smoke inhalation. The cause of death of the victims is attributed to high levels of carboxyhemoglobin, but it is not clear why the victims are unable to escape even from locations remote from flaming combustion. In an attempt to provide a model of escape from toxic gases using animals, a complex maze was built for rats with 8 choice points. The animals were 24 hr water deprived and trained to remain in the start box for 15 min. Following this period, a rat was released in the maze and had to learn to avoid blind alleys and reach the goal box for water reinforcement within 15 min. Total time to traverse and total distance in the maze were recorded. Each animal was given one trial per day. After stable running times were established, different groups of six rats were exposed to 2000, 3000, 3500, and 4000 ppm of carbon monoxide (CO) when placed in the maze. Each animal was exposed to CO only once. On the day after CO exposure the rats were implanted with an arterial cannula and on the next day each animal was exposed to the same CO concentration it had previously experienced for 30 min. Blood samples were taken every 5 min. The effect of increasing CO concentrations was to increase maze running times as well as to decrease the number of animals reaching the goal. At 3500 ppm no animal reached the goal. At 2000 ppm, the animals that failed to reach the goal moved a greater distance than animals that reached the goal.(ABSTRACT TRUNCATED AT 250 WORDS)

  1. CYCLOOXYGENASE PRODUCTS STIMULATE CARBON MONOXIDE PRODUCTION BY PIGLET CEREBRAL MICROVESSELS

    PubMed Central

    Kanu, Alie; Gilpin, David; Fedinec, Alexander L.

    2005-01-01

    Products of arachidonic acid (AA) metabolism by cyclooxygenase (COX) are important in regulation of neonatal cerebral circulation. The brain and cerebral microvessels also express heme oxygenase (HO) that metabolizes heme to carbon monoxide (CO), biliverdin, and iron. The purpose of this study in newborn pig cerebral microvessels was to address the hypothesis that COX products affect HO activity and HO products affect COX activity. AA (2.0-20μM) increased PGE2 measured by RIA and also CO measured by gas chromatography/mass spectrometry (GC-MS). Further, indomethacin (10-4M), that inhibited COX, reduced both AA and heme-induced CO production. Conversely, neither exogenous heme (2×10-6M), that markedly increased CO production, nor the inhibitor of HO, chromium mesoporphyrin, altered PGE2 synthesis. Because AA metabolism by COX generates both prostanoids and superoxides, we determined the effects of the predominant prostanoid and superoxide on CO production. While PGE2 caused a small increase in CO production, xanthine oxidase plus hypoxanthine that produces superoxide strongly stimulated the production of CO by cerebral microvessels. This increase was mildly attenuated by catalase. These data suggest that COX catalyzed AA metabolite(s), most likely superoxide, H2O2, and / or a subsequent reactive oxygen species increases cerebrovascular CO production. This increase appears to be due, at least in part, to the elevation of HO-2 catalytic activity. Conversely, COX activity is not affected by HO-catalyzed heme metabolites. These data suggest that some cerebrovascular functions attributable to COX activity could be mediated by CO. PMID:16446494

  2. The hydration structure of carbon monoxide by ab initio methods

    NASA Astrophysics Data System (ADS)

    Awoonor-Williams, Ernest; Rowley, Christopher N.

    2017-01-01

    The solvation of carbon monoxide (CO) in liquid water is important for understanding its toxicological effects and biochemical roles. In this paper, we use ab initio molecular dynamics (AIMD) and CCSD(T)-F12 calculations to assess the accuracy of the Straub and Karplus molecular mechanical (MM) model for CO(aq). The CCSD(T)-F12 CO-H2O potential energy surfaces show that the most stable structure corresponds to water donating a hydrogen bond to the C center. The MM-calculated surface incorrectly predicts that the O atom is a stronger hydrogen bond acceptor than the C atom. The AIMD simulations indicate that CO is solvated like a hydrophobic solute, with very limited hydrogen bonding with water. The MM model tends to overestimate the degree of hydrogen bonding and overestimates the atomic radius of the C atom. The calculated Gibbs energy of hydration using the TIP3P water model is in good agreement with the experiment (9.3 kJ mol-1 expt. vs 10.7 kJ mol-1 calc.). The calculated diffusivity of CO (aq) in TIP3P-model water was 5.1 ×10-5 cm2/s calc., more than double the experimental value of 2.3 ×10-5 cm2/s. The hydration energy calculated using the TIP4P-FB water model is in poorer agreement with the experiment (ΔG = 6.8 kJ/mol) but the diffusivity is in better agreement (D =2.5 ±0.1 ×10-5 cm2/s).

  3. Carbon monoxide exchange and partitioning of a managed mountain meadow

    NASA Astrophysics Data System (ADS)

    Hammerle, Albin; Kitz, Florian; Spielmann, Felix; Gerdel, Katharina; Wohlfahrt, Georg

    2016-04-01

    With an average mole fraction of 100 ppb carbon monoxide (CO) plays a critical role in atmospheric chemistry and thus has an indirect global warming potential. While sources/sinks of CO on land at least partially cancel out each other, the magnitude of CO sources and sinks is highly uncertain. Even if direct CO fluxes from/to land ecosystems are very much likely clearly lower in magnitude compared to anthropogenic emissions, biomass burning, emissions from chemical precursors and the OH sink, it may be premature to neglect any direct contributions of land ecosystems to the CO budget. In addition, changes in global climate and resulting changes in global productivity may require re-evaluating older data and assumptions. One major reason for the large uncertainty is a general scarcity of empirical data. An additional factor contributing to the uncertainty is the lack of ecosystem-scale CO exchange measurements, i.e. CO flux data that encompass all sources and sinks within an ecosystem. Here we present data on continuous eddy covariance measurements of CO-fluxes above a managed mountain grassland in combination with soil chamber flux measurements, within- and above-canopy concentration profiles and an inverse Lagrangian analysis to disentangle sinks and sources of CO. Results show the grassland ecosystem to be a net source for CO during daytime, with increasing flux rates at higher solar radiation. At night, if at all, the meadow is a slight sink for CO. The same holds true regarding the soil flux measurements. Additionally, a two-month rainout experiment revealed hardly any differences in CO soil fluxes between rainout- and control-plots unless extremely dry conditions were reached.

  4. Relationship between obstructive sleep apnea and endogenous carbon monoxide.

    PubMed

    Azuma, Masanori; Murase, Kimihiko; Tachikawa, Ryo; Hamada, Satoshi; Matsumoto, Takeshi; Minami, Takuma; Inouchi, Morito; Tanizawa, Kiminobu; Handa, Tomohiro; Oga, Toru; Mishima, Michiaki; Chin, Kazuo

    2017-01-01

    Endogenous carbon monoxide (CO) levels are recognized as a surrogate marker for activity of heme oxygenase-1, which is induced by various factors, including hypoxia and oxidative stress. Few reports have evaluated endogenous CO in patients with obstructive sleep apnea (OSA). Whether OSA more greatly affects exhaled or blood CO is not known. Sixty-nine patients with suspected OSA were prospectively included in this study. Exhaled and blood CO were evaluated at night and morning. Blood and exhaled CO levels were well correlated both at night and morning (r = 0.52, P < 0.0001 and r = 0.61, P < 0.0001, respectively). Although exhaled CO levels both at night and morning significantly correlated with total sleep time with arterial oxygen saturation < 90% (ρ = 0.41, P = 0.0005 and ρ = 0.27, P = 0.024, respectively), blood CO levels did not correlate with any sleep parameter. Seventeen patients with an apnea and hypopnea index (AHI) < 15 (control group) were compared with 52 patients with AHI ≥ 15 (OSA group). Exhaled CO levels at night in the OSA group were significantly higher than in the control group (3.64 ± 1.2 vs. 2.99 ± 0.70 ppm, P < 0.05). Exhaled CO levels at night decreased after 3 mo of continuous positive airway pressure (CPAP) therapy in OSA patients (n = 36; P = 0.016) to become nearly the same level as in the control group (P = 0.21). Blood CO levels did not significantly change after CPAP therapy. Exhaled CO was positively related to hypoxia during sleep in OSA patients, but blood CO was not. Exhaled CO might better correlate with oxidative stress associated with OSA than blood CO.

  5. Inhibition of cellular respiration by endogenously produced carbon monoxide.

    PubMed

    D'Amico, Gabriela; Lam, Francis; Hagen, Thilo; Moncada, Salvador

    2006-06-01

    Endogenously produced nitric oxide (NO) interacts with mitochondrial cytochrome c oxidase, leading to inhibition of cellular respiration. This interaction has been shown to have important physiological and pathophysiological consequences. Exogenous carbon monoxide (CO) is also known to inhibit cytochrome c oxidase in vitro; however, it is not clear whether endogenously produced CO can inhibit cellular respiration and, if so, what the significance of this might be. In this study, we show that exogenous CO inhibits respiration in a moderate but persistent manner in HEK293 cells under ambient (21%) oxygen concentrations (K(i) = 1.44 microM). This effect of CO was increased (K(i) = 0.35 microM) by incubation in hypoxic conditions (1% oxygen). Endogenous CO, generated by HEK293 cells transfected with the inducible isoform of haem oxygenase (haem oxygenase-1; HO-1), also inhibited cellular respiration moderately (by 12%) and this was accompanied by inhibition (23%) of cytochrome c oxidase activity. When the cells were incubated in hypoxic conditions during HO-1 induction, the inhibitory effect of CO on cell respiration was markedly increased to 70%. Furthermore, endogenously produced CO was found to be responsible for the respiratory inhibition that occurs in RAW264.7 cells activated in hypoxic conditions with lipopolysaccharide and interferon-gamma, in the presence of N-(iminoethyl)-L-ornithine to prevent the synthesis of NO. Our results indicate that CO contributes significantly to the respiratory inhibition in activated cells, particularly under hypoxic conditions. Inhibition of cell respiration by endogenous CO through its interaction with cytochrome c oxidase might have an important role in inflammatory and hypoxic conditions.

  6. Carbon Monoxide (CO) Is a Novel Inhibitor of Connexin Hemichannels*

    PubMed Central

    León-Paravic, Carmen G.; Figueroa, Vania A.; Guzmán, Diego J.; Valderrama, Carlos F.; Vallejos, Antonio A.; Fiori, Mariana C.; Altenberg, Guillermo A.; Reuss, Luis; Retamal, Mauricio A.

    2014-01-01

    Hemichannels (HCs) are hexamers of connexins that can form gap-junction channels at points of cell contacts or “free HCs” at non-contacting regions. HCs are involved in paracrine and autocrine cell signaling, and under pathological conditions may induce and/or accelerate cell death. Therefore, studies of HC regulation are of great significance. Nitric oxide affects the activity of Cx43 and Cx46 HCs, whereas carbon monoxide (CO), another gaseous transmitter, modulates the activity of several ion channels, but its effect on HCs has not been explored. We studied the effect of CO donors (CORMs) on Cx46 HCs expressed in Xenopus laevis oocytes using two-electrode voltage clamp and on Cx43 and Cx46 expressed in HeLa cells using a dye-uptake technique. CORM-2 inhibited Cx46 HC currents in a concentration-dependent manner. The C-terminal domain and intracellular Cys were not necessary for the inhibition. The effect of CORM-2 was not prevented by guanylyl-cyclase, protein kinase G, or thioredoxin inhibitors, and was not due to endocytosis of HCs. However, the effect of CORM-2 was reversed by reducing agents that act extracellularly. Additionally, CO inhibited dye uptake of HeLa cells expressing Cx43 or Cx46, and MCF-7 cells, which endogenously express Cx43 and Cx46. Because CORM-2 carbonylates Cx46 in vitro and induces conformational changes, a direct effect of that CO on Cx46 is possible. The inhibition of HCs could help to understand some of the biological actions of CO in physiological and pathological conditions. PMID:25384983

  7. CROSS-CORRELATIONS AS A COSMOLOGICAL CARBON MONOXIDE DETECTOR

    SciTech Connect

    Pullen, Anthony R.; Dore, Olivier; Chang, Tzu-Ching; Lidz, Adam

    2013-05-01

    We present a new procedure to measure the large-scale carbon monoxide (CO) emissions across cosmic history. As a tracer of large-scale structure (LSS), the CO gas content as a function of redshift can be quantified by its three-dimensional fluctuation power spectra. Furthermore, cross-correlating CO emission with other LSS tracers offers a way to measure the emission as a function of scale and redshift. Here we introduce the model relevant for such a cross-correlation measurement between CO and other LSS tracers, and between different CO rotational lines. We propose a novel use of cosmic microwave background (CMB) data and attempt to extract redshifted CO emissions embedded in the Wilkinson Microwave Anisotropy Probe (WMAP) data set. We cross-correlate the all-sky WMAP7 data with LSS data sets, namely, the photometric quasar sample and the luminous red galaxy sample from the Sloan Digital Sky Survey Data Releases 6 and 7, respectively. We are unable to detect a cross-correlation signal with either CO(1-0) or CO(2-1) lines, mainly due to the instrumental noise in the WMAP data. However, we are able to rule out models more than three times greater than our more optimistic model. We discuss the cross-correlation signal from the thermal Sunyaev-Zeldovich effect and dust as potential contaminants, and quantify their impact for our CO measurements. We discuss forecasts for current CMB experiments and a hypothetical future CO-focused experiment, and propose to cross-correlate CO temperature data with the Hobby-Eberly Telescope Dark Energy Experiment Ly{alpha}-emitter sample, for which a signal-to-noise ratio of 58 is possible.

  8. Carbon Monoxide Pollution and Neurodevelopment: A Public Health Concern

    PubMed Central

    Levy, Richard J.

    2015-01-01

    Although an association between air pollution and adverse systemic health effects has been known for years, the effect of pollutants on neurodevelopment has been underappreciated. Recent evidence suggests a possible link between air pollution and neurocognitive impairment and behavioral disorders in children, however, the exact nature of this relationship remains poorly understood. Infants and children are uniquely vulnerable due to the potential for exposure in both the fetal and postnatal environments during critical periods in development. Carbon monoxide (CO), a common component of indoor and outdoor air pollution, can cross the placenta to gain access to the fetal circulation and the developing brain. Thus, CO is of particular interest as a known neurotoxin and a potential public health threat. Here we review overt CO toxicity and the policies regulating CO exposure, detail the evidence suggesting a potential link between CO-associated ambient air pollution, tobacco smoke, and learning and behavioral abnormalities in children, describe the effects of subclinical CO exposure on the brain during development, and provide mechanistic insight into a potential connection between CO exposure and neurodevelopmental outcome. CO can disrupt a number of critical processes in the developing brain, providing a better understanding of how this specific neurotoxin may impair neurodevelopment. However, further investigation is needed to better define the effects of perinatal CO exposure on the immature brain. Current policies regarding CO standards were established based on evidence of cardiovascular risk in adults with pre-existing comorbidities. Thus, recent and emerging data highlighted in this review regarding CO exposure in the fetus and developing child may be important to consider when the standards and guidelines are evaluated and revised in the future. PMID:25772154

  9. Nicotine and Carbon Monoxide Exposure from Inhalation of Cigarillo Smoke

    PubMed Central

    Koszowski, Bartosz; Rosenberry, Zachary R.; Kanu, Alieu; Viray, Lauren C.; Potts, Jennifer L.; Pickworth, Wallace B.

    2015-01-01

    Background There has been an increase in the use of cigarillos in the US. People who smoke cigarillos typically also regularly smoke cigarettes (dual users). Methods We compared puffing topography, biomarkers of acute exposure [exhaled carbon monoxide (COex) and plasma nicotine] and physiologic effects from usual brand cigarette and Black & Mild cigarillo smoking in dual users (N=23) in two laboratory sessions. Results Participants (21 men) smoked an average of 17.5 cigarettes/day. Cigarillo consumption varied widely from as few as 1/week to daily. Participants were highly nicotine dependent (average FTND score: 6.3). There were statistically significant differences in smoking behavior between cigarette and cigarillo smoking in time to smoke, number of puffs, and total puff volume (all P<0.001). Average puff duration, interpuff interval average puff volume, and puff velocity did not differ between cigarettes and cigarillos. Nicotine boost was similar after both cigarettes and cigarillos. COex boost was significantly greater after cigarillo smoking compared to cigarette smoking (P<0.001). Conclusions The smoking pattern and exposure profile indicate that dual users inhale cigarillo smoke just as they inhale cigarette smoke thereby exposing themselves to considerable amounts of nicotine and other components of tobacco smoke. COex exposure results imply that cigarillo smoking may be associated with higher exposure to smoke-delivered volatile components of mainstream cigarillo smoke including carcinogens when compared to cigarettes. Impact The findings that cigarillos and cigarettes are smoked similarly in dual users are relevant to health and regulatory considerations on cigar products. PMID:26459155

  10. Cyclooxygenase products stimulate carbon monoxide production by piglet cerebral microvessels.

    PubMed

    Kanu, Alie; Gilpin, David; Fedinec, Alexander L; Leffler, Charles W

    2006-02-01

    Products of arachidonic acid (AA) metabolism by cyclooxygenase (Cox) are important in regulation of neonatal cerebral circulation. The brain and cerebral microvessels also express heme oxygenase (HO) that metabolizes heme to carbon monoxide (CO), biliverdin, and iron. The purpose of this study in newborn pig cerebral microvessels was to address the hypothesis that Cox products affect HO activity and HO products affect Cox activity. AA (2.0-20 microM) increased prostaglandin E2 (PGE2) measured by radioimmunoassay (RIA) and also CO measured by gas chromatography/mass spectrometry (GC/MS). Further, 10(-4) M indomethacin, which inhibited Cox, reduced both AA and heme-induced CO production. Conversely, neither exogenous 2 x 10(-6) M heme, which markedly increased CO production, nor the inhibitor of HO, chromium mesoporphyrin, altered PGE2 synthesis. Because AA metabolism by Cox generates both prostanoids and superoxides, we determined the effects of the predominant prostanoid and superoxide on CO production. Although PGE2 caused a small increase in CO production, xanthine oxidase plus hypoxanthine, which produces superoxide, strongly stimulated the production of CO by cerebral microvessels. This increase was mildly attenuated by catalase. These data suggest that Cox-catalyzed AA metabolites, most likely superoxide and/or a subsequent reactive oxygen species, increase cerebrovascular CO production. This increase seems to be caused, at least in part, by the elevation of HO-2 catalytic activity. Conversely, Cox activity is not affected by HO-catalyzed heme metabolites. These data suggest that some cerebrovascular functions attributable to Cox activity could be mediated by CO.

  11. Carbon monoxide inhalation increases microparticles causing vascular and CNS dysfunction

    SciTech Connect

    Xu, Jiajun; Yang, Ming; Kosterin, Paul; Salzberg, Brian M.; Milovanova, Tatyana N.; Bhopale, Veena M.; Thom, Stephen R.

    2013-12-01

    We hypothesized that circulating microparticles (MPs) play a role in pro-inflammatory effects associated with carbon monoxide (CO) inhalation. Mice exposed for 1 h to 100 ppm CO or more exhibit increases in circulating MPs derived from a variety of vascular cells as well as neutrophil activation. Tissue injury was quantified as 2000 kDa dextran leakage from vessels and as neutrophil sequestration in the brain and skeletal muscle; and central nervous system nerve dysfunction was documented as broadening of the neurohypophysial action potential (AP). Indices of injury occurred following exposures to 1000 ppm for 1 h or to 1000 ppm for 40 min followed by 3000 ppm for 20 min. MPs were implicated in causing injuries because infusing the surfactant MP lytic agent, polyethylene glycol telomere B (PEGtB) abrogated elevations in MPs, vascular leak, neutrophil sequestration and AP prolongation. These manifestations of tissue injury also did not occur in mice lacking myeloperoxidase. Vascular leakage and AP prolongation were produced in naïve mice infused with MPs that had been obtained from CO poisoned mice, but this did not occur with MPs obtained from control mice. We conclude that CO poisoning triggers elevations of MPs that activate neutrophils which subsequently cause tissue injuries. - Highlights: • Circulating microparticles (MPs) increase in mice exposed to 100 ppm CO or more. • MPs are lysed by infusing the surfactant polyethylene glycol telomere B. • CO-induced MPs cause neutrophil activation, vascular leak and CNS dysfunction. • Similar tissue injuries do not arise with MPs obtained from air-exposed, control mice.

  12. Sublimation rates of carbon monoxide and carbon dioxide from comets at large heliocentric distances

    NASA Technical Reports Server (NTRS)

    Sekanina, Zdenek

    1992-01-01

    Using a simple model for outgassing from a small flat surface area, the sublimation rates of carbon monoxide and carbon dioxide, two species more volatile than water ice that are known to be present in comets, are calculated for a suddenly activated discrete source on the rotating nucleus. The instantaneous sublimation rate depends upon the comet's heliocentric distance and the Sun's zenith angle at the location of the source. The values are derived for the constants of CO and CO2 in an expression that yields the local rotation-averaged sublimation rate as a function of the comet's spin parameters and the source's cometocentric latitude.

  13. Compact Reconnaissance Imaging Spectrometer Observations of Water Vapor and Carbon Monoxide

    NASA Technical Reports Server (NTRS)

    Smith, Michael D.; Wolff, Michael J.; Clancy, R. Todd; Murchie, Scott L.

    2009-01-01

    The Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) onboard the Mars Reconnaissance Orbiter (MRO) spacecraft began taking observations in September 2006 and has now collected more than a full Martian year of data. Retrievals performed using the near-infrared spectra obtained by CRISM are used to characterize the seasonal and spatial variation of the column abundance of water vapor and the column-averaged mixing ratio of carbon monoxide. CRISM retrievals show nominal behavior in water vapor during northern hemisphere spring and summer with maximum abundance reaching 50 precipitable micrometers. Water vapor abundance during the southern hemisphere spring and summer appears significantly reduced compared to observations by other instruments taken during previous years. The CRISM retrievals show the seasonally and globally averaged carbon monoxide mixing ratio to be 700 ppm, but with strong seasonal variations at high latitudes. The summertime near-polar carbon monoxide mixing ratio falls to 200 ppm in the south and 400 ppm in the north as carbon dioxide sublimates from the seasonal polar ice caps and dilutes noncondensable species including carbon monoxide. At low latitudes, the carbon monoxide mixing ratio varies in response to the mean seasonal cycle of surface pressure.

  14. A Fire Department Community Health Intervention to Prevent Carbon Monoxide Poisoning Following a Hurricane

    PubMed Central

    Levy, Matthew; Jenkins, J Lee; Seaman, Kevin

    2014-01-01

    Portable generators are commonly used during electrical service interruptions that occur following large storms such as hurricanes. Nearly all portable generators use carbon based fuels and produce deadly carbon monoxide gas. Despite universal warnings to operate these generators outside only, the improper placement of generators makes these devices the leading cause of engine related carbon monoxide deaths in the United States. The medical literature reports many cases of Carbon Monoxide (CO) toxicity associated with generator use following hurricanes and other weather events. This paper describes how Howard County, Maryland Fire and Rescue (HCFR) Services implemented a public education program that focused on prevention of Carbon Monoxide poisoning from portable generator use in the wake of events where electrical service interruptions occurred or had the potential to occur. A major challenge faced was communication with those members of the population who were almost completely dependent upon electronic and wireless technologies and were without redundancies. HCFR utilized several tactics to overcome this challenge including helicopter based surveillance and the use of geocoded information from the electrical service provider to identify outage areas. Once outage areas were identified, HCFR personnel conducted a door-to-door canvasing of effected communities, assessing for hazards and distributing information flyers about the dangers of generator use. This effort represents one of the first reported examples of a community-based endeavor by a fire department to provide proactive interventions designed to prevent carbon monoxide illness. PMID:24596660

  15. A population-based exposure assessment methodology for carbon monoxide: Development of a carbon monoxide passive sampler and occupational dosimeter

    SciTech Connect

    Apte, Michael G.

    1997-09-01

    Two devices, an occupational carbon monoxide (CO) dosimeter (LOCD), and an indoor air quality (IAQ) passive sampler were developed for use in population-based CO exposure assessment studies. CO exposure is a serious public health problem in the U.S., causing both morbidity and mortality (lifetime mortality risk approximately 10{sup -4}). Sparse data from population-based CO exposure assessments indicate that approximately 10% of the U.S. population is exposed to CO above the national ambient air quality standard. No CO exposure measurement technology is presently available for affordable population-based CO exposure assessment studies. The LOCD and IAQ Passive Sampler were tested in the laboratory and field. The palladium-molybdenum based CO sensor was designed into a compact diffusion tube sampler that can be worn. Time-weighted-average (TWA) CO exposure of the device is quantified by a simple spectrophotometric measurement. The LOCD and IAQ Passive Sampler were tested over an exposure range of 40 to 700 ppm-hours and 200 to 4200 ppm-hours, respectively. Both devices were capable of measuring precisely (relative standard deviation <20%), with low bias (<10%). The LOCD was screened for interferences by temperature, humidity, and organic and inorganic gases. Temperature effects were small in the range of 10°C to 30°C. Humidity effects were low between 20% and 90% RH. Ethylene (200 ppm) caused a positive interference and nitric oxide (50 ppm) caused a negative response without the presence of CO but not with CO.

  16. Proton exchange membrane fuel cell reversible performance loss induced by carbon monoxide produced during operation

    NASA Astrophysics Data System (ADS)

    Decoopman, B.; Vincent, R.; Rosini, S.; Paganelli, G.; Thivel, P.-X.

    2016-08-01

    Cyclic voltammetry measurements at the anode have been carried out and reveal the presence of carbon monoxide in steady-state operation, with pure hydrogen. Experiments have been performed both in single cell and in stack to find out its origin. The contamination of the anode catalyst is partly due the reverse-water gas shift (RWGS) with carbon dioxide from the cathode. However, this study shows a temperature-activated and time-related corrosion mechanism which appears under humidified hydrogen. Due to this degradation mechanism, a reversible 25 mV-loss of performances is observed and can be recovered by oxidizing carbon monoxide on the anode.

  17. Anaerobic transformation of carbon monoxide by microbial communities of Kamchatka hot springs.

    PubMed

    Kochetkova, Tatiana V; Rusanov, Igor I; Pimenov, Nikolay V; Kolganova, Tatyana V; Lebedinsky, Alexander V; Bonch-Osmolovskaya, Elizaveta A; Sokolova, Tatyana G

    2011-05-01

    Carbon monoxide (CO) is one of the common gaseous compounds found in hot volcanic environments. It is known to serve as the growth substrate for a number of thermophilic prokaryotes, both aerobic and anaerobic. The goal of this work was to study the process of anaerobic transformation of CO by microbial communities inhabiting natural thermal environments: hot springs of Uzon Caldera, Kamchatka. The anaerobic microbial community of Treshchinny Spring (80°C, pH 6.5) was found to exhibit two peaks of affinity for CO (K (S1) = 54 nM and K (S2) = 1 μM). The actual rate of anaerobic CO transformation by the microbial community of this spring, calculated after obtaining the concentration dependence curve and extrapolated to the natural concentration of CO dissolved in the hot spring water (20 nM), was found to be 120 μmol l(-1) of sediment day(-1). In all the hot springs studied, more than 90% of the carbon of (14)CO upon anaerobic incubation was recovered as (14)CO(2). From 1 to 5% of (14)CO was transformed to volatile fatty acids (VFA). The number of microorganisms capable of anaerobic CO oxidation determined by dilution-to-extinction method reached 10(6) cells ml(-1) of sediment. CO-transforming anaerobic thermophilic microorganisms isolated from the springs under study exhibited hydrogenogenic type of CO oxidation and belonged to the bacterial genera Carboxydocella and Dictyoglomus. These data suggest a significant role of hydrogenogenic carboxydotrophic prokaryotes in anaerobic CO transformation in Uzon Caldera hot springs.

  18. Risk and Protective Factors for Fires, Burns, and Carbon Monoxide Poisoning in U.S. Households

    PubMed Central

    Runyan, Carol W.; Johnson, Renee M.; Yang, Jingzhen; Waller, Anna E.; Perkis, David; Marshall, Stephen W.; Coyne-Beasley, Tamera; McGee, Kara S.

    2011-01-01

    Background More needs to be known about the prevalence of risk and protective factors for fires, burns, and carbon monoxide poisoning in U.S. households. Methods A random-digit-dial survey was conducted about home safety with 1003 respondents representing households in the continental United States. Descriptive statistics assess the prevalence of risk and protective factors for fires, burns, and carbon monoxide overall, and by demographic characteristics, household structure, region, and residential tenure. The data were weighted to adjust for nonresponse and to reflect the U.S. population. Results Although most respondents reported having a smoke alarm (97%), and 80% reported having one on each level of their home, <20% reported checking the alarm at least every 3 months. Seventy-one percent reported having a fire extinguisher, 29% had a carbon monoxide detector, and 51% of those living with at least one other person had a fire escape plan. Few could report the temperature of their hot water at the tap (9%), or the setting on the hot water heater (25%). Only 6% had an antiscald device. Conclusions Results suggest that there is much room for improvement regarding adoption of measures to prevent fires, burns, and carbon monoxide poisoning. Further investigations of the efficacy of carbon monoxide detectors, fire extinguishers, and escape plans, as well as effectiveness studies of fire and burn-prevention efforts are needed. PMID:15626564

  19. Carbon monoxide and lethal arrhythmias. Research report, Jul 85-Jan 89

    SciTech Connect

    Farber, J.P.; Schwartz, P.J.; Vanoli, E.; Stramba-Badiale, M.

    1990-01-01

    The effect of acute exposure to carbon monoxide on ventricular arrhythmias was studied in dogs with a healed anterior myocardial infarction. The combination of mild exercise and acute myocardial ischemia induces ventricular fibrillation in 60 percent of the animals. Dogs that develop ventricular fibrillation are considered at high risk for sudden death and are defined as susceptible; dogs that survive the test without fatal arrhythmia are considered at low risk and are defined as 'resistant.' The effects of carboxyhemoglobin levels ranging from 5 to 15 percent were tested in resistant and susceptible dogs. A trend toward higher heart rates was observed at rest and during exercise in both resistant and susceptible dogs at all levels of carboxyhemoglobin, although significant differences were observed only with 15 percent carboxyhemoglobin. In resistant animals, in which acute myocardial ischemia is typically associated with bradycardia even under the control condition, the reflex response occurred earlier and was augmented after exposure to carbon monoxide. In both resistant and susceptible dogs, carbon monoxide exposure induced a worsening of ventricular arrhythmias in a minority of cases. The worsening was not reproducible in subsequent trials. These data indicate that acute exposure to carbon monoxide is seldom arrhythmogenic in dogs that have survived myocardial infarction. Nevertheless, the observation that carbon monoxide exposure increases heart rate at rest and during moderate exercise may have clinical implications relevant to patients with coronary artery disease.

  20. Infrared spectroscopic measurements of carbon monoxide within a high temperature ablative boundary layer

    NASA Astrophysics Data System (ADS)

    McGuire, S. D.; Tibère-Inglesse, A. C.; Laux, C. O.

    2016-12-01

    Theoretical studies have indicated that the formation of carbon monoxide within a high temperature ablative boundary layer can significantly alter the afterbody radiative heat transfer to the surface of a reentry capsule. This paper represents a first attempt to experimentally measure the concentration of carbon monoxide within the high temperature boundary layer surrounding an ablative material exposed to an atmospheric pressure air plasma. A plasma torch facility was used to produce the high temperature flow and a sample of ASTERM ablative material was inserted into the flow. At the stagnation point, the heat flux to the surface was estimated at 8 MW m-2 and the surface temperature at 2900  ±  100 K. Both emission and absorption spectroscopy techniques were used to measure the distribution of carbon monoxide within the flow. Emission spectroscopy yielded better signal-to-noise measurements, but the absorption spectroscopy measurements were used to validate emission measurements. In the cases examined, both emission and absorption measurements were consistent and in agreement with one another. Estimates of carbon monoxide temperature and mole fraction were deduced from the spectra taken within the boundary layer downstream of the stagnation point. No carbon monoxide was observed at the stagnation point. These measurements provide a test case for numerical simulations of plasma-ablator interactions.

  1. New clean fuel from coal -- Direct dimethyl ether synthesis from hydrogen and carbon monoxide

    SciTech Connect

    Ogawa, T.; Ono, M.; Mizuguchi, M.; Tomura, K.; Shikada, T.; Ohono, Y.; Fujimoto, K.

    1997-12-31

    Dimethyl ether (DME), which has similar physical properties to propane and is easily liquefied at low pressure, has a significant possibility as a clean and non-toxic fuel from coal or coal bed methane. Equilibrium calculation also shows a big advantage of high carbon monoxide conversion of DME synthesis compared to methanol synthesis. By using a 50 kg/day DME bench scale test plant, direct synthesis of DME from hydrogen and carbon monoxide has been studied with newly developed catalysts which are very fine particles. This test plant features a high pressure three-phase slurry reactor and low temperature DME separator. DME is synthesized at temperatures around 533--553 K and at pressures around 3--5 MPa. According to the reaction stoichiometry, the same amount of hydrogen and carbon monoxide react to DME and carbon dioxide. Carbon conversion to DME is one third and the rest of carbon is converted to carbon dioxide. As a result of the experiments, make-up CO conversion is 35--50% on an once-through basis, which is extremely high compared to that of methanol synthesis from hydrogen and carbon monoxide. DME selectivity is around 60 c-mol %. Most of the by-product is CO{sub 2} with a small amount of methanol and water. No heavy by-products have been recognized. Effluent from the reactor is finally cooled to 233--253 K in a DME separator and liquid DME is recovered as a product.

  2. Carbon monoxide total column retrievals from TROPOMI shortwave infrared measurements

    NASA Astrophysics Data System (ADS)

    Landgraf, Jochen; aan de Brugh, Joost; Scheepmaker, Remco; Borsdorff, Tobias; Hu, Haili; Houweling, Sander; Butz, Andre; Aben, Ilse; Hasekamp, Otto

    2016-10-01

    The Tropospheric Monitoring Instrument (TROPOMI) spectrometer is the single payload of the Copernicus Sentinel 5 Precursor (S5P) mission. It measures Earth radiance spectra in the shortwave infrared spectral range around 2.3 µm with a dedicated instrument module. These measurements provide carbon monoxide (CO) total column densities over land, which for clear sky conditions are highly sensitive to the tropospheric boundary layer. For cloudy atmospheres over land and ocean, the column sensitivity changes according to the light path through the atmosphere. In this study, we present the physics-based operational S5P algorithm to infer atmospheric CO columns satisfying the envisaged accuracy ( < 15 %) and precision ( < 10 %) both for clear sky and cloudy observations with low cloud height. Here, methane absorption in the 2.3 µm range is combined with methane abundances from a global chemical transport model to infer information on atmospheric scattering. For efficient processing, we deploy a linearized two-stream radiative transfer model as forward model and a profile scaling approach to adjust the CO abundance in the inversion. Based on generic measurement ensembles, including clear sky and cloudy observations, we estimated the CO retrieval precision to be ≤ 11 % for surface albedo ≥ 0.03 and solar zenith angle ≤ 70°. CO biases of ≤ 3 % are introduced by inaccuracies in the methane a priori knowledge. For strongly enhanced CO concentrations in the tropospheric boundary layer and for cloudy conditions, CO errors in the order of 8 % can be introduced by the retrieval of cloud parameters of our algorithm. Moreover, we estimated the effect of a distorted spectral instrument response due to the inhomogeneous illumination of the instrument entrance slit in the flight direction to be < 2 % with pseudo-random characteristics when averaging over space and time. Finally, the CO data exploitation is demonstrated for a TROPOMI orbit of simulated shortwave infrared

  3. Carbon monoxide in breath in relation to smoking and carboxyhaemoglobin levels.

    PubMed

    Wald, N J; Idle, M; Boreham, J; Bailey, A

    1981-05-01

    Carboxyhaemoglobin (COHb) levels were studied in 11 249 men. The distribution among the 2613 men who smoked cigarettes was well separated from that in 6641 non-smokers (including ex-smokers). The distribution for 2005 cigar and pipe smokers was intermediate, though some of the highest COHb levels occurred in cigar smokers. Using a COHb cut-off level of 2%, 81% of cigarette smokers, 35% of cigar and pipe smokers, and 1.0% of non-smokers had raised COHb levels. In a subsidiary experiment alveolar air samples were collected from 162 smokers and 25 non-smokers using a simple breath sampling technique. Carbon monoxide concentrations in alveolar breath were highly correlated with COHb levels (r = 0.97) indicating that COHb levels can be estimated reliably by measuring the concentration of carbon monoxide in breath. Alveolar carbon monoxide measurement is thus a simple method of estimating whether a person is likely to be a smoker.

  4. Preparation and evaluation of self-regenerative carbon monoxide detection gels

    NASA Astrophysics Data System (ADS)

    Palmer, J. G.; Cecil, M.; Schrauzer, G. N.; Shuler, K. E.

    1982-09-01

    Continued development of an especially impregnated silica gel capable of reversible chemical detection of carbon monoxide was reported. The effects of changes in mine related ambient conditions on the detection catalyst's response were explored. Temperature, humidity, and several interfering gases were found to affect the detection catalyst. The interferents include hydrogen sulfide, nitrogen dioxide, acetylene (and methylacetylene), and ammonia. High humnidity decreased the detection catalyst's sensitivity to carbon monoxide for some formulations. Increasing temperature generally decreased the reaction time of the detection catalyst with carbon monoxide. A limited physical, chemical, and mechanistic characterization of the detection catalyst and the materials used to prepare it has been carried out. Metal component ratio studies, spectral, analytical, pH, and rate measurements were done.

  5. Substantially isotactic, linear, alternating copolymers of carbon monoxide and an olefin

    DOEpatents

    Sen, Ayusman; Jiang, Zhaozhong

    1996-01-01

    The compound, [Pd(Me-DUPHOS)(MeCN).sub.2 ](BF.sub.4).sub.2, [Me-DUPHOS: 1,2-bis(2,5-dimethylphospholano)benzene] is an effective catalyst for the highly enantioselective, alternating copolymerization of olefins, such as aliphatic .alpha.-olefins, with carbon monoxide to form optically active, isotactic polymers which can serve as excellent starting materials for the synthesis of other classes of chiral polymers. For example, the complete reduction of a propylene-carbon monoxide copolymer resulted in the formation of a novel, optically active poly(1,4-alcohol). Also, the previously described catalyst is a catalyst for the novel alternating isomerization cooligomerization of 2-butene with carbon monoxide to form optically active, isotactic poly(1,5-ketone)

  6. Substantially isotactic, linear, alternating copolymers of carbon monoxide and an olefin

    DOEpatents

    Sen, A.; Jiang, Z.

    1996-05-28

    The compound, [Pd(Me-DUPHOS)(MeCN){sub 2}](BF{sub 4}){sub 2}, [Me-DUPHOS: 1,2-bis(2,5-dimethylphospholano)benzene] is an effective catalyst for the highly enantioselective, alternating copolymerization of olefins, such as aliphatic {alpha}-olefins, with carbon monoxide to form optically active, isotactic polymers which can serve as excellent starting materials for the synthesis of other classes of chiral polymers. For example, the complete reduction of a propylene-carbon monoxide copolymer resulted in the formation of a novel, optically active poly(1,4-alcohol). Also, the previously described catalyst is a catalyst for the novel alternating isomerization cooligomerization of 2-butene with carbon monoxide to form optically active, isotactic poly(1,5-ketone).

  7. Does public education reduce ice storm-related carbon monoxide exposure?

    PubMed

    Lin, George; Conners, Gregory P

    2005-11-01

    Public education to prevent carbon monoxide exposure during ice storms has been recommended; its effects remain unexamined. We compared patients seen for carbon monoxide inhalation at the area's only academic Emergency Department during 1991 and 2003 ice storms; educational efforts were more intense in 2003. There were fewer patients during the second storm (45 vs. 55); all recovered fully. The percentage of Caucasian patients rose (from 57% to 89%) whereas that of African-American patients fell (from 39% to 7%). Indoor grill use, associated with 11% of 1991 cases, was eliminated in 2003. Indoor gas generators remain the most common source. Carboxyhemoglobin levels correlate poorly with ambient carbon monoxide levels. Enhanced public education had a modest effect, especially in reducing the proportion of African-American patients and those from indoor grill use. Research on more effective public health education targeted at gas generator users and combined with physical interventions should be considered.

  8. [Carboxyhemoglobin concentration in carbon monoxide poisoning. Critical appraisal of the predictive value].

    PubMed

    Köthe, L; Radke, J

    2010-06-01

    In cases of unclear depression of conciousness, arrhythmia and symptoms of cardiac insufficiency inadvertent carbon monoxide intoxication should always be taken into consideration. Rapid diagnosis of acute carbon monoxide intoxication with mostly unspecific symptoms requires an immediate supply of high dose oxygen which enables a distinct reduction of mortality and long-term morbidity. Levels of carboxyhemoglobin, however, should not be used as a parameter to decide whether to supply normobaric or the more efficient hyperbaric oxygen. There is no sufficient coherence between carboxyhemoglobin blood levels and clinical symptoms. Increased carboxyhemoglobin concentrations help to diagnose acute carbon monoxide intoxication but do not allow conclusions to be drawn about possible long-term neuropsychiatric or cardiac consequences.

  9. Carbon Monoxide Accumulation in the Extravehicular Mobility Unit

    NASA Technical Reports Server (NTRS)

    Conkin, J.; Norcrosss, J. R.; Alexander, D. J.; Sanders, R. W.; Makowski, M. S.

    2016-01-01

    Introduction: Life support technology in large closed systems like submarines and space stations catalyzes carbon monoxide (CO) to carbon dioxide, which is easily removed. However, in a small system like the Extravehicular Mobility Unit (EMU), spacesuit, CO from exogenous (contaminated oxygen (O (sub 2) supply) and endogenous (human metabolism) sources will accumulate in the free suit volume. The free volume becomes a sink for CO that is rebreathed by the astronaut. The accumulation through time depends on many variables: the amount absorbed by the astronaut, the amount produced by the astronaut (between 0.28 and 0.34 ?moles per hour per kilogram)[1], the amount that enters the suit from contaminated O (sub 2), the amount removed through suit leak, the free volume of the suit, and the O (sub 2) partial pressure[2], just to list a few. Contamination of the EMU O (sub 2) supply with no greater than 1 part per million CO was the motivation for empirical measurements from CO pulse oximetry (SpCO) as well as mathematical modeling of the EMU as a rebreather for CO. Methods: We developed a first-order differential mixing equation as well as an iterative method to compute CO accumulation in the EMU. Pre-post measurements of SpCO (Rad-57, Masimo Corporation) from EMU ground training and on-orbit extravehicular activities (EVAs) were collected. Results: Initial modeling without consideration of the astronaut as a sink but only the source of CO showed that after 8 hours breathing 100 percent O (sub 2) with a 10 milliliter per minute (760 millimeters Hg at 21 degrees Centigrade standard) suit leak, an endogenous production rate of 0.23 moles per hour per kilogram for a 70 kilogram person with 42 liters (1.5 cubic feet) free suit volume resulted in a peak CO partial pressure (pCO) of 0.047 millimeters Hg at 4.3 pounds per square inch absolute (222 millimeters Hg). Preliminary results based on a 2008 model[3] with consideration of the astronaut as a sink and source of CO

  10. Occupational carbon monoxide poisoning in the State of Washington, 1994-1999.

    PubMed

    Lofgren, Don J

    2002-04-01

    Carbon monoxide poisonings continue to be significant and preventable for a number of work operations. This study assesses occupational carbon monoxide morbidity and mortality for the state of Washington based on a review of workers' compensation records for the years 1994-1999. The study characterizes sources, industries, and causative factors, and further attempts to identify work operations most at risk. Records were identified by both injury source and diagnostic codes. The study limits itself to non-fire-related carbon monoxide poisonings and primarily those from acute exposure. A decline in the number of claims was not evident, but the number of incidents per year showed a slight decline. Carbon monoxide poisonings were found to occur throughout all types of industries. The greatest number of claims was found in agriculture, followed by construction and wholesale trade, with these three accounting for more than half the claims and nearly half of the incidents. The more severe poisonings did not necessarily occur in industries with the greatest number of incidents. The major source for carbon monoxide poisoning was forklift trucks, followed by auto/truck/bus, portable saws, and more than 20 other sources. Fruit packing and storage had the highest number of incidents mostly due to fuel-powered forklift activity, with nearly half of the incidents occurring in cold rooms. Adverse health effects as measured by carboxyhemoglobin, hyperbaric oxygen treatment, unconsciousness, and number and cost of claims were indexed by source. Though several specific work operations were identified, the episodic nature of carbon monoxide poisonings, as well as the diverse industries and sources, and the opportunity for a severe poisoning in any number of operations, poses challenges for effective intervention.

  11. The photochemistry of methane and carbon monoxide in the troposphere in 1950 and 1985

    NASA Technical Reports Server (NTRS)

    Levine, J. S.; Rinsland, C. P.; Tennille, G. M.

    1985-01-01

    The roughly 1 percent/year increase in tropospheric methane and roughly 2 percent/year increase in tropospheric carbon monoxide deduced from recent analyses of ground-based solar infrared spectra recorded in 1950 and 1951 have very important implications for the photochemistry and chemistry of the troposphere. Photochemical calculations indicate that as a result of the increase of methane and carbon monoxide since 1950-51, levels of the hydroxyl radical, the key species in the photochemistry of the troposphere, may have decreased by about 25 percent.

  12. Occupational carbon monoxide violations in the State of Washington, 1994-1999.

    PubMed

    Lofgren, Don J

    2002-07-01

    Occupational exposure to carbon monoxide continues to cause a number of injuries and deaths. This study reviewed the State of Washington OSHA inspection records for occupational safety or health violations related to carbon monoxide for the time period 1994-1999 to assess the agency's efforts and further identify and characterize causative factors. Inspection data were also compared with carbon monoxide claims data from a companion study to determine if the agency was visiting the most at risk work operations. Inspections were identified by searching computerized violation texts for "carbon monoxide" or "CO." The study found 142 inspections with one or more carbon monoxide violations. Inspections were spread over 84 different 4-digit Standard Industrial Classification codes. Most inspections were initiated as a result of a complaint or other informant. Inspections were predominantly in construction and manufacturing, whereas carbon monoxide claims were mores evenly distributed between the major industries. Inspections also may have failed to find violations for some types of equipment responsible for carbon monoxide claims. Forklifts were the source of carbon monoxide most often associated with a violation, followed by compressors for respirators, auto/truck/bus, and temporary heating devices. Inspections in response to poisonings found common factors associated with lack of recognition and failure to use or maintain equipment and ventilation. Some work sites with one or more poisonings were not being inspected. Only 10 of the 51 incidents with industrial insurance claim reports of carboxyhemoglobin at or above 20 percent were inspected. Further, it was found more preventive efforts should be targeted at cold storage operations and certain warehouse and construction activities. It is proposed that more specific standards, both consensus and regulatory, would provide additional risk reduction. Reliance upon safe work practices as a primary method of control in the

  13. Cerebral infarction due to carotid occlusion and carbon monoxide exposure III. Influence of neck vein occlusion.

    PubMed Central

    Laas, R; Igloffstein, J

    1983-01-01

    Unilateral cerebral infarcts were produced in the rat by ligation of one common carotid artery and a subsequent exposure to carbon monoxide. In animals which had undergone an additional ligation of the external jugular veins leading to a moderate increase of the cephalic venous pressure the outcome of the procedure was ameliorated significantly. Venous pressure elevation was thought to reduce the venous vascular resistance effectively by preventing the leptomeningeal veins from collapsing. Collapse of the leptomeningeal veins probably occurred during the severe carbon monoxide-induced hypotension causing a steep increase of cerebral vascular resistance. Images PMID:6886722

  14. Catalytic polymerization of carbon monoxide and olefin, with organo nitro or organo nitrite compound additive

    SciTech Connect

    Drent, E.; Wife, R.L.

    1989-02-21

    In the process of producing linear alternating polymers or carbon monoxide and at least one ethylenically unsaturated hydrocarbon by contacting the carbon monoxide and unsaturated hydrocarbon under polymerization conditions in the presence of a catalyst composition formed from a mixture of a palladium compound, the anion of a non-hydrohalogenic acid having a pKa below about 6 and a bidentate phosphorus ligand, the improvement wherein the mixture from which the catalyst composition is formed additionally contains an organic nitro compound or an organic nitride compound.

  15. Process for producing methane from gas streams containing carbon monoxide and hydrogen

    DOEpatents

    Frost, Albert C.

    1980-01-01

    Carbon monoxide-containing gas streams are passed over a catalyst capable of catalyzing the disproportionation of carbon monoxide so as to deposit a surface layer of active surface carbon on the catalyst essentially without formation of inactive coke thereon. The surface layer is contacted with steam and is thus converted to methane and CO.sub.2, from which a relatively pure methane product may be obtained. While carbon monoxide-containing gas streams having hydrogen or water present therein can be used only the carbon monoxide available after reaction with said hydrogen or water is decomposed to form said active surface carbon. Although hydrogen or water will be converted, partially or completely, to methane that can be utilized in a combustion zone to generate heat for steam production or other energy recovery purposes, said hydrogen is selectively removed from a CO--H.sub.2 -containing feed stream by partial oxidation thereof prior to disproportionation of the CO content of said stream.

  16. Fresh meat packaging: consumer acceptance of modified atmosphere packaging including carbon monoxide.

    PubMed

    Grebitus, Carola; Jensen, Helen H; Roosen, Jutta; Sebranek, Joseph G

    2013-01-01

    Consumers' perceptions and evaluations of meat quality attributes such as color and shelf life influence purchasing decisions, and these product attributes can be affected by the type of fresh meat packaging system. Modified atmosphere packaging (MAP) extends the shelf life of fresh meat and, with the inclusion of carbon monoxide (CO-MAP), achieves significant color stabilization. The objective of this study was to assess whether consumers would accept specific packaging technologies and what value consumers place on ground beef packaged under various atmospheres when their choices involved the attributes of color and shelf life. The study used nonhypothetical consumer choice experiments to determine the premiums that consumers are willing to pay for extended shelf life resulting from MAP and for the "cherry red" color in meat resulting from CO-MAP. The experimental design allowed determination of whether consumers would discount foods with MAP or CO-MAP when (i) they are given more detailed information about the technologies and (ii) they have different levels of individual knowledge and media exposure. The empirical analysis was conducted using multinomial logit models. Results indicate that consumers prefer an extension of shelf life as long as the applied technology is known and understood. Consumers had clear preferences for brighter (aerobic and CO) red color and were willing to pay $0.16/lb ($0.35/kg) for each level of change to the preferred color. More information on MAP for extending the shelf life and on CO-MAP for stabilizing color decreased consumers' willingness to pay. An increase in personal knowledge and media exposure influenced acceptance of CO-MAP negatively. The results provide quantitative measures of how packaging affects consumers' acceptance and willingness to pay for products. Such information can benefit food producers and retailers who make decisions about investing in new packaging methods.

  17. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas.

    PubMed

    Onodera, Makoto; Fujino, Yasuhisa; Kikuchi, Satoshi; Sato, Masayuki; Mori, Kiyofumi; Beppu, Takaaki; Inoue, Yoshihiro

    2016-01-01

    Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been observed. Method. The subjects included patients treated for acute carbon monoxide poisoning in whom a medical emergency team was able to measure the carboxyhemoglobin level at the site of poisoning. We examined the relationship between the carboxyhemoglobin level at the site of poisoning and carbon monoxide exposure time and the relationships between the arterial blood carboxyhemoglobin level and carbon monoxide exposure time. Results. A total of 10 patients met the above criteria. The carboxyhemoglobin levels at the site of poisoning were significantly and positively correlated with the exposure time (rs = 0.710, p = 0.021), but the arterial blood carboxyhemoglobin levels were not correlated with the exposure time. Conclusion. In rural areas, the carboxyhemoglobin level measured at the site of carbon monoxide poisoning correlated with the exposure time.

  18. On the effect of carbon monoxide addition on soot formation in a laminar ethylene/air coflow diffusion flame

    SciTech Connect

    Guo, Hongsheng; Thomson, Kevin A.; Smallwood, Gregory J.

    2009-06-15

    The effect of carbon monoxide addition on soot formation in an ethylene/air diffusion flame is investigated by experiment and detailed numerical simulation. The paper focuses on the chemical effect of carbon monoxide addition by comparing the results of carbon monoxide and nitrogen diluted flames. Both experiment and simulation show that although overall the addition of carbon monoxide monotonically reduces the formation of soot, the chemical effect promotes the formation of soot in an ethylene/air diffusion flame. The further analysis of the details of the numerical result suggests that the chemical effect of carbon monoxide addition may be caused by the modifications to the flame temperature, soot surface growth and oxidation reactions. Flame temperature increases relative to a nitrogen diluted flame, which results in a higher surface growth rate, when carbon monoxide is added. Furthermore, the addition of carbon monoxide increases the concentration of H radical owing to the intensified forward rate of the reaction CO + OH = CO{sub 2} + H and therefore increases the surface growth reaction rates. The addition of carbon monoxide also slows the oxidation rate of soot because the same reaction CO + OH = CO{sub 2} + H results in a lower concentration of OH. (author)

  19. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas

    PubMed Central

    Onodera, Makoto; Fujino, Yasuhisa; Kikuchi, Satoshi; Sato, Masayuki; Mori, Kiyofumi; Beppu, Takaaki; Inoue, Yoshihiro

    2016-01-01

    Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been observed. Method. The subjects included patients treated for acute carbon monoxide poisoning in whom a medical emergency team was able to measure the carboxyhemoglobin level at the site of poisoning. We examined the relationship between the carboxyhemoglobin level at the site of poisoning and carbon monoxide exposure time and the relationships between the arterial blood carboxyhemoglobin level and carbon monoxide exposure time. Results. A total of 10 patients met the above criteria. The carboxyhemoglobin levels at the site of poisoning were significantly and positively correlated with the exposure time (rs = 0.710, p = 0.021), but the arterial blood carboxyhemoglobin levels were not correlated with the exposure time. Conclusion. In rural areas, the carboxyhemoglobin level measured at the site of carbon monoxide poisoning correlated with the exposure time. PMID:27239377

  20. Observation of black carbon, ozone and carbon monoxide in the Kali Gandaki Valley Nepal

    NASA Astrophysics Data System (ADS)

    Dhungel, S.; Panday, A. K.; Kathayat, B.

    2014-12-01

    The increased melting of snow and ice in the arctic and the Himalaya is a growing concern for all of the earth's population. Deposition of black carbon (BC) on the snow and ice surface accelerates melting by absorbing the radiative energy and directly transferring all that energy onto the underlying surface. During pre-monsoon season, satellite images show a thick layer of haze covering the Indo-Gangetic plain (IGP) and the Himalayan foothills. Sub-micron particles are transported to the Himalaya from the IGP predominantly driven by the thermal valley wind system. The Himalayas consist of some of the tallest mountain ranges in the world, over 8000m tall that reach the stratosphere. The Kali Gandaki Valley in Nepal is one of the deepest gorges in the world, and has some of the highest up-valley winds in the world. It is also one of the most open connecting points for air from IGP to reach the Tibetan Plateau. In 2010 the University of Virginia, in collaboration with ICIMOD and Nepal Wireless, established an atmospheric research station in Jomsom, Nepal (28.78N, 83.42E, 2900 m.a.s.l.) half-way along the Kali Gandaki valley. The station is equipped to measure black carbon (BC), carbon monoxide (CO), and ozone concentrations. It also has an automated weather station, a filter sampler, and a NASA Aeronet Sunphotometer. Here we present our observations of black carbon, ozone, carbon monoxide at Jomsom to show the diurnal and seasonal variability of the pollutants. The results show diurnal patterns in the concentration of these pollutants and also episodes of high pollutant transport along the valley. These transport episodes are more common during the pre-monsoon season which indicates that deep mountain valleys like the Kali Gandaki valley facilitate the transport of pollutants and thus promote snow and glacial melting.

  1. Gold Nanoparticles Supported on Carbon Nitride: Influence of Surface Hydroxyls on Low Temperature Carbon Monoxide Oxidation

    SciTech Connect

    Singh, Joseph A; Dudney, Nancy J; Li, Meijun; Overbury, Steven {Steve} H; Veith, Gabriel M

    2012-01-01

    This paper reports the synthesis of 2.5 nm gold clusters on the oxygen free and chemically labile support carbon nitride (C3N4). Despite having small particle sizes and high enough water partial pressure these Au/C3N4 catalysts are inactive for the gas phase and liquid phase oxidation of carbon monoxide. The reason for the lack of activity is attributed to the lack of surface OH groups on the C3N4. These OH groups are argued to be responsible for the activation of CO in the oxidation of CO. The importance of basic OH groups explains the well document dependence of support isoelectric point versus catalytic activity.

  2. Diagnosing black carbon trends in large urban areas using carbon monoxide measurements

    NASA Astrophysics Data System (ADS)

    Baumgardner, Darrel; Raga, G.; Peralta, O.; Rosas, I.; Castro, T.; Kuhlbusch, T.; John, A.; Petzold, A.

    2002-11-01

    The relationship between black carbon (BC) and carbon monoxide (CO) has been analyzed using measurements from two sites in Mexico City and five urban areas in Germany. The correlation coefficient between BC and CO is greater than 0.90 for all sites. The average slope of the linear regression line for BC versus CO is 2.2 μg mg-1 for German sites and 1.1 μg mg-1 in Mexico City. The most important factors that affect the BC to CO relationship appear to be the ratio of diesel to gasoline usage and the combustion efficiency of vehicles in a particular area. The results of this analysis suggest that CO measurements in urban areas can be used to estimate BC mass when direct measurements are not available.

  3. Conversion of carbon dioxide to carbon monoxide by pulse dielectric barrier discharge plasma

    NASA Astrophysics Data System (ADS)

    Wang, Taobo; Liu, Hongxia; Xiong, Xiang; Feng, Xinxin

    2017-01-01

    The conversion of carbon dioxide (CO2) to carbon monoxide (CO) was investigated in a non-thermal plasma dielectric barrier discharge (DBD) reactor, and the effects of different process conditions on the CO2 conversion were investigated. The results showed that the increase of input power could optimize the conversion of CO2 to CO. The CO2 conversion and CO yield were negatively correlated with the gas flow rate, but there was an optimum gas flow rate, that made the CO selectivity best. The carrier gas (N2, Ar) was conducive to the conversion of CO2, and the effect of N2 as carrier gas was better than Ar. The conversion of CO2 to CO was enhanced by addition of the catalyst (5A molecular sieve).

  4. Electrocatalytic reduction of carbon dioxide to carbon monoxide and methane at an immobilized cobalt protoporphyrin

    PubMed Central

    Shen, Jing; Kortlever, Ruud; Kas, Recep; Birdja, Yuvraj Y.; Diaz-Morales, Oscar; Kwon, Youngkook; Ledezma-Yanez, Isis; Schouten, Klaas Jan P.; Mul, Guido; Koper, Marc T. M.

    2015-01-01

    The electrochemical conversion of carbon dioxide and water into useful products is a major challenge in facilitating a closed carbon cycle. Here we report a cobalt protoporphyrin immobilized on a pyrolytic graphite electrode that reduces carbon dioxide in an aqueous acidic solution at relatively low overpotential (0.5 V), with an efficiency and selectivity comparable to the best porphyrin-based electrocatalyst in the literature. While carbon monoxide is the main reduction product, we also observe methane as by-product. The results of our detailed pH-dependent studies are explained consistently by a mechanism in which carbon dioxide is activated by the cobalt protoporphyrin through the stabilization of a radical intermediate, which acts as Brønsted base. The basic character of this intermediate explains how the carbon dioxide reduction circumvents a concerted proton–electron transfer mechanism, in contrast to hydrogen evolution. Our results and their mechanistic interpretations suggest strategies for designing improved catalysts. PMID:26324108

  5. Simulations of exercise and brain effects of acute exposure to carbon monoxide in normal and vascular-diseased persons.

    PubMed

    Benignus, Vernon A; Coleman, Thomas G

    2010-04-01

    At some level, carboxyhemoglobin (COHb) due to inhalation of carbon monoxide (CO) reduces maximum exercise duration in both normal and ischemic heart patients. At high COHb levels in normal subjects, brain function is also affected and behavioral performance is impaired.These are findings from published experiments that are, due to ethical or practical considerations, incomplete in that higher or lower ranges of COHb, and exercise have not been well studied. To fill in this knowledge base, a whole-body human physiological model was used to make estimates of physiological functioning by the simulation of parametric exposures to CO and various exercise levels. Ischemic heart disease was simulated by introducing a stenosis in the left heart arterial supply. Brain blood flow was also limited by such a stenosis. To lend credibility to such estimation, the model was tested by simulating experiments from the published literature. Simulations permitted several new conclusions. Increases in COHb produced the largest decreases in exercise duration when exercise was least strenuous and when COHb was smallest. For ischemic heart disease subjects, the greatest change in exercise duration produced by COHb increase was when ischemia and COHb was smallest. Brain aerobic metabolism was unaffected until COHb exceeded 25%, unless the maximum brain blood supply was limited by a stenosis greater than 50% of normal. For higher levels of stenosis, aerobic brain metabolism was reduced for any increase in COHb level, implying that behavior would be impaired with no "threshold" for COHb.

  6. Integrated Science Assessment (ISA) for Carbon Monoxide (First External Review Draft, Mar 2009)

    EPA Science Inventory

    EPA announced that the First External Review Draft of the Integrated Science Assessment (ISA) for Carbon Monoxide (CO) and related Annexes was made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluation of th...

  7. Integrated Science Assessment (ISA) for Carbon Monoxide (Final Report, Jan 2010)

    EPA Science Inventory

    EPA announced the availability of the final report, Integrated Science Assessment (ISA) for Carbon Monoxide (CO). This report is EPA’s latest evaluation of the scientific literature on the potential human health and welfare effects associated with ambient exposures to CO...

  8. Integrated Science Assessment (ISA) for Carbon Monoxide (Second External Review Draft, Sep 2009)

    EPA Science Inventory

    EPA announced that the Second External Review Draft of the Integrated Science Assessment (ISA) for Carbon Monoxide (CO) and related Annexes was made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluation of t...

  9. CARBON MONOXIDE REVERSIBLY DISRUPTS IRON HOMEOSTATIS AND RESPIRATORY EPITHELIAL CELLS FUNCTION

    EPA Science Inventory

    Iron dissociation from heme is a major factor in iron metabolism and cellular concentrations of the metal correlate inversely with the expression of heme oxygenase (HO). We tested the hypothesis that 1) exposure to a product of HO, carbon monoxide (CO), disturbs iron homeostas...

  10. Operations and maintenance manual, atmospheric contaminant sensor. Addendum 1: Carbon monoxide monitor model 204

    NASA Technical Reports Server (NTRS)

    1972-01-01

    An instrument for monitoring the carbon monoxide content of the ambient atmosphere is described. The subjects discussed are: (1) theory of operation, (2) system features, (3) controls and monitors, (4) operational procedures, and (5) maintenance and troubleshooting. Block drawings and circuit diagrams are included to clarify the text.

  11. Modelling of Carbon Monoxide Air Pollution in Larg Cities by Evaluetion of Spectral LANDSAT8 Images

    NASA Astrophysics Data System (ADS)

    Hamzelo, M.; Gharagozlou, A.; Sadeghian, S.; Baikpour, S. H.; Rajabi, A.

    2015-12-01

    Air pollution in large cities is one of the major problems that resolve and reduce it need multiple applications and environmental management. Of The main sources of this pollution is industrial activities, urban and transport that enter large amounts of contaminants into the air and reduces its quality. With Variety of pollutants and high volume manufacturing, local distribution of manufacturing centers, Testing and measuring emissions is difficult. Substances such as carbon monoxide, sulfur dioxide, and unburned hydrocarbons and lead compounds are substances that cause air pollution and carbon monoxide is most important. Today, data exchange systems, processing, analysis and modeling is of important pillars of management system and air quality control. In this study, using the spectral signature of carbon monoxide gas as the most efficient gas pollution LANDSAT8 images in order that have better spatial resolution than appropriate spectral bands and weather meters،SAM classification algorithm and Geographic Information System (GIS ), spatial distribution of carbon monoxide gas in Tehran over a period of one year from the beginning of 2014 until the beginning of 2015 at 11 map have modeled and then to the model valuation ،created maps were compared with the map provided by the Tehran quality comparison air company. Compare involved plans did with the error matrix and results in 4 types of care; overall, producer, user and kappa coefficient was investigated. Results of average accuracy were about than 80%, which indicates the fit method and data used for modeling.

  12. [Suicidal carbon monoxide poisoning in an electric car. An unusual case report].

    PubMed

    Bohnert, M; Zollinger, U

    1994-01-01

    The authors report a case of a man who committed suicide by poisoning with carbon monoxide in his electric vehicle. He applied a small motor generator with no exhaust normally used for charging the vehicle's batteries at home, that was found on the loading space behind the seat. This demonstrates the value of a thorough scene investigation.

  13. CARBON MONOXIDE FLUXES OF DIFFERENT SOIL LAYERS IN UPLAND CANADIAN BOREAL FORESTS

    EPA Science Inventory

    Dark or low-light carbon monoxide fluxes at upland Canadian boreal forest sites were measured on-site with static chambers and with a laboratory incubation technique using cores from different depths at the same sites. Three different upland black spruce sites, burned in 1987,199...

  14. Reaction engineering for materials processing in space: Reduction of ilmenite by hydrogen and carbon monoxide

    NASA Technical Reports Server (NTRS)

    Zhao, Y.; Shadman, F.

    1991-01-01

    Oxygen is a consumable material which needs to be produced continuously in most space missions. Its use for propulsion as well as life support makes oxygen one of the largest volume chemicals to be produced in space. Production of oxygen from lunar materials is of particular interest and is very attractive possibility. The kinetics and mechanism of reduction of ilmenite by carbon monoxide and hydrogen at 800 to 1100 C were investigated. The temporal profiles of conversion for carbon monoxide have a sigmoidal shape and indicate the presence of three different stages (induction, acceleration, and deceleration) during the reduction reaction. The apparent activation energy decreases from 18 kcal/mole at 10 percent conversion to 10 kcal/mole at 50 percent conversion. The reaction is first order with respect to carbon monoxide under the experimental conditions studied. Both SEM and EDX analysis show that the diffusion of Fe product away from the reaction front and through the TiO2 phase, followed by the nucleation and growth of a separate Fe phase are important steps affecting the process kinetics. The results from hydrogen reduction show that the mechanism of ilmenite reduction by hydrogen is similar to that by carbon monoxide. However, the titanium dioxide can be further reduced by hydrogen at 800 to 1000 C. The detailed comparison and theoretical modeling of both reduction processes is presented.

  15. 40 CFR 52.269 - Control strategy and regulations: Photochemical oxidants (hydrocarbons) and carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...: Photochemical oxidants (hydrocarbons) and carbon monoxide. 52.269 Section 52.269 Protection of Environment... PLANS California § 52.269 Control strategy and regulations: Photochemical oxidants (hydrocarbons) and... provide for attainment and maintenance of the national standards for photochemical oxidants...

  16. 40 CFR 52.269 - Control strategy and regulations: Photochemical oxidants (hydrocarbons) and carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...: Photochemical oxidants (hydrocarbons) and carbon monoxide. 52.269 Section 52.269 Protection of Environment... PLANS California § 52.269 Control strategy and regulations: Photochemical oxidants (hydrocarbons) and... provide for attainment and maintenance of the national standards for photochemical oxidants...

  17. 40 CFR 52.269 - Control strategy and regulations: Photochemical oxidants (hydrocarbons) and carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...: Photochemical oxidants (hydrocarbons) and carbon monoxide. 52.269 Section 52.269 Protection of Environment... PLANS California § 52.269 Control strategy and regulations: Photochemical oxidants (hydrocarbons) and... provide for attainment and maintenance of the national standards for photochemical oxidants...

  18. 40 CFR 52.269 - Control strategy and regulations: Photochemical oxidants (hydrocarbons) and carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...: Photochemical oxidants (hydrocarbons) and carbon monoxide. 52.269 Section 52.269 Protection of Environment... PLANS California § 52.269 Control strategy and regulations: Photochemical oxidants (hydrocarbons) and... provide for attainment and maintenance of the national standards for photochemical oxidants...

  19. 40 CFR 52.269 - Control strategy and regulations: Photochemical oxidants (hydrocarbons) and carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...: Photochemical oxidants (hydrocarbons) and carbon monoxide. 52.269 Section 52.269 Protection of Environment... PLANS California § 52.269 Control strategy and regulations: Photochemical oxidants (hydrocarbons) and... provide for attainment and maintenance of the national standards for photochemical oxidants...

  20. Inhalation Toxicology. 11. The Effect of Elevated Temperature on Carbon Monoxide Toxicity

    DTIC Science & Technology

    1990-12-01

    TEMPERATURE ON CARBON MONOXIDE TOXICITY INTRODUCTION The use of the laboratory rat as an animal model for determining the toxicity of combustion gases is...response of rats during exercise. J Appl Physiol. 1968; 24:747-50. 7. Hubbard RW, Matthew WT, Linduska JD, et al. The laboratory rat as a model for

  1. Pits confined in ultrathin cerium(IV) oxide for studying catalytic centers in carbon monoxide oxidation

    NASA Astrophysics Data System (ADS)

    Sun, Yongfu; Liu, Qinghua; Gao, Shan; Cheng, Hao; Lei, Fengcai; Sun, Zhihu; Jiang, Yong; Su, Haibin; Wei, Shiqiang; Xie, Yi

    2013-11-01

    Finding ideal material models for studying the role of catalytic active sites remains a great challenge. Here we propose pits confined in an atomically thin sheet as a platform to evaluate carbon monoxide catalytic oxidation at various sites. The artificial three-atomic-layer thin cerium(IV) oxide sheet with approximately 20% pits occupancy possesses abundant pit-surrounding cerium sites having average coordination numbers of 4.6 as revealed by X-ray absorption spectroscopy. Density-functional calculations disclose that the four- and five-fold coordinated pit-surrounding cerium sites assume their respective role in carbon monoxide adsorption and oxygen activation, which lowers the activation barrier and avoids catalytic poisoning. Moreover, the presence of coordination-unsaturated cerium sites increases the carrier density and facilitates carbon monoxide diffusion along the two-dimensional conducting channels of surface pits. The atomically thin sheet with surface-confined pits exhibits lower apparent activation energy than the bulk material (61.7 versus 122.9 kJ mol-1), leading to reduced conversion temperature and enhanced carbon monoxide catalytic ability.

  2. 40 CFR 52.2428 - Control Strategy: Carbon monoxide and ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ozone. 52.2428 Section 52.2428 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control Strategy: Carbon monoxide and ozone. (a) Determination—EPA has determined that, as of November 5, 1997, the Richmond ozone nonattainment area, which consists of the counties of Chesterfield,...

  3. 40 CFR 51.241 - Nonattainment areas for carbon monoxide and ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and ozone. 51.241 Section 51.241 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Intergovernmental Consultation Agency Designation § 51.241 Nonattainment areas for carbon monoxide and ozone. (a... ozone will not be attained by July 1, 1979, the Governor (or Governors for interstate areas)...

  4. 40 CFR 51.241 - Nonattainment areas for carbon monoxide and ozone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and ozone. 51.241 Section 51.241 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Intergovernmental Consultation Agency Designation § 51.241 Nonattainment areas for carbon monoxide and ozone. (a... ozone will not be attained by July 1, 1979, the Governor (or Governors for interstate areas)...

  5. 40 CFR 52.2428 - Control Strategy: Carbon monoxide and ozone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ozone. 52.2428 Section 52.2428 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control Strategy: Carbon monoxide and ozone. (a) Determination—EPA has determined that, as of November 5, 1997, the Richmond ozone nonattainment area, which consists of the counties of Chesterfield,...

  6. 40 CFR 51.241 - Nonattainment areas for carbon monoxide and ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... and ozone. 51.241 Section 51.241 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Intergovernmental Consultation Agency Designation § 51.241 Nonattainment areas for carbon monoxide and ozone. (a... ozone will not be attained by July 1, 1979, the Governor (or Governors for interstate areas)...

  7. 40 CFR 51.241 - Nonattainment areas for carbon monoxide and ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and ozone. 51.241 Section 51.241 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Intergovernmental Consultation Agency Designation § 51.241 Nonattainment areas for carbon monoxide and ozone. (a... ozone will not be attained by July 1, 1979, the Governor (or Governors for interstate areas)...

  8. 40 CFR 51.241 - Nonattainment areas for carbon monoxide and ozone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and ozone. 51.241 Section 51.241 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Intergovernmental Consultation Agency Designation § 51.241 Nonattainment areas for carbon monoxide and ozone. (a... ozone will not be attained by July 1, 1979, the Governor (or Governors for interstate areas)...

  9. 40 CFR 52.2428 - Control Strategy: Carbon monoxide and ozone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... ozone. 52.2428 Section 52.2428 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control Strategy: Carbon monoxide and ozone. (a) Determination—EPA has determined that, as of November 5, 1997, the Richmond ozone nonattainment area, which consists of the counties of Chesterfield,...

  10. 40 CFR 52.2428 - Control Strategy: Carbon monoxide and ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... ozone. 52.2428 Section 52.2428 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control Strategy: Carbon monoxide and ozone. (a) Determination—EPA has determined that, as of November 5, 1997, the Richmond ozone nonattainment area, which consists of the counties of Chesterfield,...

  11. 40 CFR 52.2428 - Control Strategy: Carbon monoxide and ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ozone. 52.2428 Section 52.2428 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control Strategy: Carbon monoxide and ozone. (a) Determination—EPA has determined that, as of November 5, 1997, the Richmond ozone nonattainment area, which consists of the counties of Chesterfield,...

  12. SEASONAL SOIL FLUXES OF CARBON MONOXIDE IN BURNED AND UNBURNED BRAZILIAN SAVANNAS

    EPA Science Inventory

    Soil-atmosphere fluxes of carbon monoxide (CO) were measured from September 1999 through November 2000 in savanna areas in central Brazil (Cerrado) under different fire regimes using transparent and opaque static chambers. Studies focused on two vegetation types, cerrado stricto...

  13. Connections between Concepts Revealed by the Electronic Structure of Carbon Monoxide

    ERIC Educational Resources Information Center

    Liu, Ying; Liu, Bihui; Liu, Yue; Drew, Michael G. B.

    2012-01-01

    Different models for the electronic structure of carbon monoxide are suggested in influential textbooks. Therefore, this electronic structure offers an interesting subject in teaching because it can be used as an example to relate seemingly conflicting concepts. Understanding the connections between ostensibly different methods and between…

  14. VCD spectroscopy as an excellent probe of chiral metal complexes containing a carbon monoxide vibrational chromophore.

    PubMed

    Fusè, Marco; Mazzeo, Giuseppe; Longhi, Giovanna; Abbate, Sergio; Zerla, Daniele; Rimoldi, Isabella; Contini, Alessandro; Cesarotti, Edoardo

    2015-06-07

    Vibrational circular dichroism, VCD, gives evidence that the carbon monoxide chromophore in a heteroleptic cyclopentadienyl Ru(ii)-carbonyl complex is very sensitive to the chirality of the metal centre and becomes an excellent probe to define the configuration of chiral metal complexes.

  15. Evaluation of Length-of-Stain Gas Indicator Tubes for Measuring Carbon Monoxide in Air.

    ERIC Educational Resources Information Center

    Klaubert, Earl C.; And Others

    Techniques for detection and measurement of carbon monoxide (CO) in air are of interest and utility in many aspects of automotive safety. CO concentrations may range from less than 100 parts per million (ppm), or 0.01 percent, to about 10 percent by volume. Gas indicator tubes have been used for many years primarily as detectors of hazardous gases…

  16. Microwave Radiometer for Spectral Observations of Mesospheric Carbon Monoxide at 115 GHz Over Kharkiv, Ukraine

    NASA Astrophysics Data System (ADS)

    Piddyachiy, Valeriy; Shulga, Valerii; Myshenko, Valeriy; Korolev, Alexey; Antyufeyev, Oleksandr; Shulga, Dmytro; Forkman, Peter

    2017-03-01

    We present the results of the development of high sensitivity microwave radiometer designed for observation of the atmospheric carbon monoxide (CO) emission lines at 115 GHz. The receiver of this radiometer has the double-sideband noise temperature of 250 K at a temperature of 10°C. To date, this is the best noise performance for uncooled Schottky diode mixer receiver systems. The designed radiometer was tested during the 2014-2015 period at observations of the carbon monoxide emission lines over Kharkiv, Ukraine (50° N, 36.3° E). These tests have shown the reliability of the receiver system, which allows us in the future to use designed radiometer for continuous monitoring of carbon monoxide. The first observations of the atmospheric carbon monoxide spectral lines over Kharkiv have confirmed seasonal changes in the CO abundance and gave us reasons to assume the spread of the influence of the polar vortex on the state of the atmosphere up to the latitude of 50° N where our measurement system is located.

  17. Fatal carbon monoxide poisoning after the detonation of explosives in an underground mine: a case report.

    PubMed

    Markey, M A; Zumwalt, R E

    2001-12-01

    An unusual death caused by carbon monoxide poisoning after the detonation of explosives in an underground mine was investigated by the Office of the Medical Investigator of the State of New Mexico. The 50-year-old miner had 18 years of mining experience but no documented safety training. He collapsed approximately 20 minutes after entering the mine and working at the bottom of the single vertical shaft. The tight confines of the mine shaft hindered rescue personnel from reaching him, and the body was not recovered until 2 days later. The autopsy showed severe coronary artery atherosclerosis with remote and resolving myocardial microinfarcts, as well as the characteristic pink lividity of carbon monoxide poisoning, which was confirmed by laboratory analysis. Detailed investigation of the scene revealed no sources of carbon monoxide other than the explosives. The case represents an uncommon cause of death in mining that may have been avoided through the use of proper safety procedures, and illustrates the importance of recognizing the many sources of carbon monoxide.

  18. EDUCATION LEVEL IS GREATEST RISK-FACTOR IN CARBON MONOXIDE POISONING

    EPA Science Inventory

    Carbon monoxide (CO) is a toxic by-product of the combustion of fossil fuels. In confined spaces, inefficient combustion sources, such as furnaces, stoves, kerosene heaters and automobiles can generate levels of CO that interrupt oxygen transport throughout the body, potentially ...

  19. Development and application of lightweight instruments for vertical profiling of ozone and carbon monoxide

    NASA Astrophysics Data System (ADS)

    Bognar, John Andrew

    1998-09-01

    This thesis covers the development of low cost, lightweight instrumentation for vertical profiling measurements of ozone and carbon monoxide in the troposphere. These instruments are designed to fly on small, low-payload airborne platforms such as tethered kites and blimps. Thus, they can be used for making measurements from light aircraft as well. Due to their small size and low cost, they are also suitable for use as disposable sondes on released balloons or in dropsondes. The design and test results of a simple single-beam ultraviolet photometer for ozone measurements are presented. A novel airflow system and advanced electronics are among the most important changes from earlier reported systems. The current version of the instrument fits into a package 8 x 8 x 40 cm, weighs under 0.5 kg, and consumes approximately 8 watts of power. Independent measurements of ozone are made every six seconds, with a sensitivity of 0.3 ppbv ozone and a precision of 2%. The design and test results of a simple carbon monoxide detector based on the reducing gas detector principle are also presented. It operates by reacting carbon monoxide with mercuric oxide to produce mercury vapor, which may then be measured via ultraviolet absorption to compute the concentration of carbon monoxide. This instrument has several features which distinguish it from similar carbon monoxide analyzers, all of which contribute to its usefulness on small airborne platforms. It fits a package 10 x 20 x 25 cm, has a mass of 2.0 kg, and consumes an average of 20 watts of power. An independent measurement of carbon monoxide is made every eight seconds, with a sensitivity of 3 ppbv carbon monoxide and a precision of 4%. The packages these instruments are flown in are described, and other associated instruments in the packages are briefly covered. Two major packages are described: one for kites and blimps, and the other for light aircraft. These packages, while having a similar design architecture, have some

  20. Unique case of fatal carbon monoxide poisoning in the absence of a combustible fossil fuel.

    PubMed

    Morgan, D R; Poon, P; Titley, J; Jagger, S F; Rutty, G N

    2001-09-01

    A 37-year-old man died as a result of exposure to carbon monoxide within an apartment. An investigation of the apartment showed no gas appliances or gas supply to the apartment and no evidence of any combustion event to any part of the apartment or roof space. Inhalation of dichloromethane was excluded. Heating to the apartment was found to be via an electrical storage heater, the examination of which revealed that the cast-iron core and insulating material showed evidence of heat damage with significant areas devoid of carbon. This electric storage heater is hypothesized to be the source of carbon for the fatal production of carbon monoxide within the apartment.

  1. Characteristics of Children with Acute Carbon Monoxide Poisoning in Ankara: A Single Centre Experience.

    PubMed

    Unsal Sac, Rukiye; Taşar, Medine Ayşin; Bostancı, İlknur; Şimşek, Yurda; Bilge Dallar, Yıldız

    2015-12-01

    The purpose of the study was to define characteristics of children with acute carbon monoxide poisoning. Eighty children hospitalized with acute carbon monoxide poisoning were recruited prospectively over a period of 12 months. Sociodemographic features, complaints and laboratory data were recorded. When the patient was discharged, necessary preventive measures to be taken were explained to parents. One month later, the parents were questioned during a control examination regarding the precautions that they took. The ages of the cases were between one month and 16 yr. Education levels were low in 86.2% of mothers and 52.6% of fathers. All families had low income and 48.8% did not have formal housing. The source of the acute carbon monoxide poisoning was stoves in 71.2% of cases and hot-water heaters in 28.8% of cases. Three or more people were poisoned at home in 85.1% of the cases. The most frequent symptoms of poisoning were headache and vertigo (58.8%). Median carboxyhemoglobin levels at admission to the hospital and discharge were measured as 19.5% and 1.1% (P < 0.001). When families were called for re-evaluation, it was determined that most of them had taken the necessary precautions after the poisoning incident (86.3%). This study determined that children with acute childhood carbon monoxide poisoning are usually from families with low socioeconomic and education levels. Education about prevention should be provided to all people who are at risk of carbon monoxide poisoning before a poisoning incident occurs.

  2. Characteristics of Children with Acute Carbon Monoxide Poisoning in Ankara: A Single Centre Experience

    PubMed Central

    Unsal Sac, Rukiye; Bostancı, İlknur; Şimşek, Yurda; Bilge Dallar, Yıldız

    2015-01-01

    The purpose of the study was to define characteristics of children with acute carbon monoxide poisoning. Eighty children hospitalized with acute carbon monoxide poisoning were recruited prospectively over a period of 12 months. Sociodemographic features, complaints and laboratory data were recorded. When the patient was discharged, necessary preventive measures to be taken were explained to parents. One month later, the parents were questioned during a control examination regarding the precautions that they took. The ages of the cases were between one month and 16 yr. Education levels were low in 86.2% of mothers and 52.6% of fathers. All families had low income and 48.8% did not have formal housing. The source of the acute carbon monoxide poisoning was stoves in 71.2% of cases and hot-water heaters in 28.8% of cases. Three or more people were poisoned at home in 85.1% of the cases. The most frequent symptoms of poisoning were headache and vertigo (58.8%). Median carboxyhemoglobin levels at admission to the hospital and discharge were measured as 19.5% and 1.1% (P < 0.001). When families were called for re-evaluation, it was determined that most of them had taken the necessary precautions after the poisoning incident (86.3%). This study determined that children with acute childhood carbon monoxide poisoning are usually from families with low socioeconomic and education levels. Education about prevention should be provided to all people who are at risk of carbon monoxide poisoning before a poisoning incident occurs. PMID:26713060

  3. Molten metal reactor and method of forming hydrogen, carbon monoxide and carbon dioxide using the molten alkaline metal reactor

    DOEpatents

    Bingham, Dennis N.; Klingler, Kerry M.; Turner, Terry D.; Wilding, Bruce M.

    2012-11-13

    A molten metal reactor for converting a carbon material and steam into a gas comprising hydrogen, carbon monoxide, and carbon dioxide is disclosed. The reactor includes an interior crucible having a portion contained within an exterior crucible. The interior crucible includes an inlet and an outlet; the outlet leads to the exterior crucible and may comprise a diffuser. The exterior crucible may contain a molten alkaline metal compound. Contained between the exterior crucible and the interior crucible is at least one baffle.

  4. Use of Carbon Isotopes in the Analysis of the Tropospheric Carbon Monoxide Budget

    NASA Astrophysics Data System (ADS)

    Emmons, L. K.; Hess, P.; Lamarque, J.; Mak, J.; Orlando, J.; Granier, C.

    2003-12-01

    The budget of carbon monoxide (CO) includes emissions from combustion of fossil fuels and biomass, as well as chemical production from the oxidation of methane and higher hydrocarbons, with the primary sink being reaction with OH. The lifetime of CO is on the order of months, so CO serves as a good tracer of pollution long distances from source regions. The CO isotopic signature varies depending on the type of emissions, and thus can provide additional information about the contributions of different emissions. Measurements of 13CO have been made at a number of locations, showing distinct seasonal and interannual variations. We have added 13CO and its precursors (CH4 and other hydrocarbons) to the NCAR/MPI/GFDL global chemical transport model MOZART, including the 13C emissions and fractionation rates, to assist in the interpretation of the 13CO measurements. The individual emission types have been `tagged' for different regions, to further quantify the CO budget.

  5. Asphyxial deaths caused by automobile exhaust inhalation not attributable to carbon monoxide toxicity: study of 2 cases.

    PubMed

    Schmunk, Gregory A; Kaplan, James A

    2002-06-01

    The authors report two suicides that resulted from the intentional inhalation of automobile exhaust gases in which death occurred without the formation of physiologically significant amounts of carboxyhemoglobin. These circumstances are correlated with measurements of the involved vehicles' exhaust gases, which showed reduced concentrations of carbon monoxide present, reflecting improvements in automobile engine technology. In the absence of carbon monoxide toxicity, the authors attribute death in these cases to asphyxia caused by carbon dioxide intoxication and diminished atmospheric oxygen concentrations.

  6. Carbon Monoxide as an Electron Donor for the Biological Reduction of Sulphate

    PubMed Central

    Parshina, Sofiya N.; Sipma, Jan; Henstra, Anne Meint; Stams, Alfons J. M.

    2010-01-01

    Several strains of Gram-negative and Gram-positive sulphate-reducing bacteria (SRB) are able to use carbon monoxide (CO) as a carbon source and electron donor for biological sulphate reduction. These strains exhibit variable resistance to CO toxicity. The most resistant SRB can grow and use CO as an electron donor at concentrations up to 100%, whereas others are already severely inhibited at CO concentrations as low as 1-2%. Here, the utilization, inhibition characteristics, and enzymology of CO metabolism as well as the current state of genomics of CO-oxidizing SRB are reviewed. Carboxydotrophic sulphate-reducing bacteria can be applied for biological sulphate reduction with synthesis gas (a mixture of hydrogen and carbon monoxide) as an electron donor. PMID:20628586

  7. Carbon monoxide is not always a poison gas for human organism: Physiological and pharmacological features of CO.

    PubMed

    Olas, Beata

    2014-10-05

    Carbon monoxide (CO) is an odorless, colorless and non-irritating gas. Even a small amount of CO exposure is possibly associated with specific toxic effects. CO is also produced endogenously in the body as a byproduct of heme degradation catalyzed by heme oxygenase. More recently CO has been identified as a gasotransmitter in various biological systems. However, the biological role and the therapeutic potential of carbon monoxide is not clear. This review summarizes the negative and the positive functions of carbon monoxide in various biological systems, including cardiovascular system.

  8. Use of carbon monoxide combined with carbon dioxide for modified atmosphere packaging of pre- and postrigor fresh pork sausage to improve shelf life.

    PubMed

    Laury, Angela; Sebranek, Joseph G

    2007-04-01

    Fresh pre- and postrigor pork sausage patties were manufactured in the Iowa State University Meat Laboratory and packaged either in modified atmosphere (MAP) with 0.4% carbon monoxide (CO) and 99.6% carbon dioxide (CO2) or on foam trays overwrapped with oxygen-permeable film (OW). Packages were stored at 2 to 40C under fluorescent lights for up to 31 days. Aerobic, anaerobic, and psychrotrophic plate counts, raw and cooked color, purge, and lipid oxidation were measured during storage. Results indicated that both pork sausage products in MAP had lower aerobic and psychrotrophic counts and less lipid oxidation throughout storage (P < 0.05). Raw color of both products in MAP was redder than the OW patties (P < 0.05), but the prerigor pork sausage in MAP benefited more from the CO atmosphere in terms of raw color than the postrigor pork sausage in MAP. Cooked color of the prerigor pork sausage in MAP was significantly redder than cooked color of the postrigor pork sausage. Both pork sausage products in MAP were also lighter (L* value) than the OW patties for raw and cooked color. Therefore, the combination of CO and CO2 in MAP was beneficial in extending the shelf life of pre-and postrigor fresh pork sausage by reducing aerobic and psychrotrophic microbial growth and improving oxidative stability and color, compared to conventional OW packaging. However, increased purge, increased anaerobic growth, and changes in cooking behavior were also observed for the products in MAP during storage (P < 0.05).

  9. Carbon Dioxide in Exoplanetary Atmospheres: Rarely Dominant Compared to Carbon Monoxide and Water in Hot, Hydrogen-dominated Atmospheres

    NASA Astrophysics Data System (ADS)

    Heng, Kevin; Lyons, James R.

    2016-02-01

    We present a comprehensive study of the abundance of carbon dioxide in exoplanetary atmospheres in hot, hydrogen-dominated atmospheres. We construct novel analytical models of systems in chemical equilibrium that include carbon monoxide, carbon dioxide, water, methane and acetylene and relate the equilibrium constants of the chemical reactions to temperature and pressure via the tabulated Gibbs free energies. We prove that such chemical systems may be described by a quintic equation for the mixing ratio of methane. By examining the abundances of these molecules across a broad range of temperatures (spanning equilibrium temperatures from 600 to 2500 K), pressures (via temperature-pressure profiles that explore albedo and opacity variations) and carbon-to-oxygen ratios, we conclude that carbon dioxide is subdominant compared to carbon monoxide and water. Atmospheric mixing does not alter this conclusion if carbon dioxide is subdominant everywhere in the atmosphere. Carbon dioxide and carbon monoxide may attain comparable abundances if the metallicity is greatly enhanced, but this property is negated by temperatures above 1000 K. For hydrogen-dominated atmospheres, our generic result has the implication that retrieval studies may wish to set the subdominance of carbon dioxide as a prior of the calculation and not let its abundance completely roam free as a fitting parameter, because it directly affects the inferred value of the carbon-to-oxygen ratio and may produce unphysical conclusions. We discuss the relevance of these implications for the hot Jupiter WASP-12b and suggest that some of the previous results are chemically impossible. The relative abundance of carbon dioxide to acetylene is potentially a sensitive diagnostic of the carbon-to-oxygen ratio.

  10. Manufacture of a gas containing carbon monoxide and hydrogen gas from a starting material containing carbon and/or hydrocarbon

    SciTech Connect

    Santen, S.; Johansson, B.

    1984-08-21

    In a process for manufacturing a gas substantially containing carbon monoxide and hydrogen gas from a starting material containing carbon and/or hydrocarbon, the starting material is injected in powder or liquid form together with an oxidizing agent and slag former in a combustion zone while heat energy is simultaneously supplied. The combustion zone is formed in the lower portion of a shaft filled with particulate, solid, carbonaceous material and sulphur-binding slag former.

  11. Carbon monoxide tolerant platinum electrocatalysts on niobium doped titania and carbon nanotube composite supports

    NASA Astrophysics Data System (ADS)

    Rigdon, William A.; Huang, Xinyu

    2014-12-01

    In the anode of electrochemical cells operating at low temperature, the hydrogen oxidation reaction is susceptible to poisoning from carbon monoxide (CO) which strongly adsorbs on platinum (Pt) catalysts and increases activation overpotential. Adsorbed CO is removed by oxidative processes such as electrochemical stripping, though cleaning can also cause corrosion. One approach to improve the tolerance of Pt is through alloying with less-noble metals, but the durability of alloyed electrocatalysts is a critical concern. Without sacrificing stability, tolerance can be improved by careful design of the support composition using metal oxides. The bifunctional mechanism is promoted at junctions of the catalyst and metal oxides used in the support. Stable metal oxides can also form strong interactions with catalysts, as is the case for platinum on titania (TiOx). In this study, niobium (Nb) serves as an electron donor dopant in titania. The transition metal oxides are joined to functionalized multi-wall carbon nanotube (CNT) supports in order to synthesize composite supports. Pt is then deposited to form electrocatalysts which are characterized before fabrication into anodes for tests as an electrochemical hydrogen pump. Comparisons are made between the control from Pt-CNT to Pt-TiOx-CNT and Pt-Ti0.9Nb0.1Ox-CNT in order to demonstrate advantages.

  12. Photochemical production and microbial consumption of carbon monoxide in the Caribbean Sea as influenced by the Orinoco River

    SciTech Connect

    Jones, R.D. )

    1990-01-09

    Carbon monoxide is an important trace gas in the surface waters of the marine environment. An understanding of the mechanisms by which this gas is produced and consumed is important to our understanding carbon cycling in the world's oceans. Carbon monoxide is produced by photochemical processes involving dissolved organic material (DOM) and consumed by microorganism. Major rivers greatly influence the DOM content of the oceans. The Orinoco River of Venezuela inputs its waters into the Caribbean Sea and can, thus, influence production and consumption of carbon monoxide. Microbial consumption rates and photoproduction capacity for carbon monoxide were determined along 2 Caribbean cruise tracks during the spring (low river flow) and fall (high river flow) of 1988. Carbon monoxide production capacity was highest during the fall and the Orinoco influenced a greater area of the Caribbean than during the spring. The highest production capacity was observed in the waters of 22 ppt salinity during the fall and 6.5 ppt during the spring. Correlation of microbial consumption with the highest consumption rate occurring in waters with the highest production capacity. Turnover times for carbon monoxide were as low as 2.2 h, indicating the importance of microbial consumption in these waters.

  13. Non-convulsive status epilepticus in a patient with carbon-monoxide poisoning treated with hyperbaric oxygen therapy.

    PubMed

    Marziali, Simone; Di Giuliano, Francesca; Picchi, Eliseo; Natoli, Silvia; Leonardis, Carlo; Leonardis, Francesca; Garaci, Francesco; Floris, Roberto

    2016-12-01

    The presentation of carbon monoxide poisoning is non-specific and highly variable. Hyperbaric oxygen therapy is used for the treatment of this condition. Various reports show the occurrence of self-limiting seizures after carbon monoxide poisoning and as a consequence of hyperbaric oxygen therapy. Contrary to the seizures, status epilepticus has been rarely observed in these conditions. The exact pathophysiology underlying seizures and status epilepticus associated with carbon monoxide poisoning and hyperbaric oxygen therapy is not really clear, and some elements appear to be common to both conditions. We describe a case of non-convulsive status epilepticus in a patient with carbon monoxide poisoning treated with hyperbaric oxygen therapy. The mechanism, MRI findings and implications are discussed.

  14. Contributions of distinct gold species to catalytic reactivity for carbon monoxide oxidation

    NASA Astrophysics Data System (ADS)

    Guo, Li-Wen; Du, Pei-Pei; Fu, Xin-Pu; Ma, Chao; Zeng, Jie; Si, Rui; Huang, Yu-Ying; Jia, Chun-Jiang; Zhang, Ya-Wen; Yan, Chun-Hua

    2016-11-01

    Small-size (<5 nm) gold nanostructures supported on reducible metal oxides have been widely investigated because of the unique catalytic properties they exhibit in diverse redox reactions. However, arguments about the nature of the gold active site have continued for two decades, due to the lack of comparable catalyst systems with specific gold species, as well as the scarcity of direct experimental evidence for the reaction mechanism under realistic working conditions. Here we report the determination of the contribution of single atoms, clusters and particles to the oxidation of carbon monoxide at room temperature, by the aid of in situ X-ray absorption fine structure analysis and in situ diffuse reflectance infrared Fourier transform spectroscopy. We find that the metallic gold component in clusters or particles plays a much more critical role as the active site than the cationic single-atom gold species for the room-temperature carbon monoxide oxidation reaction.

  15. Cortical venous infarcts and acute limb ischaemia in acute carbon monoxide poisoning: A rare case report.

    PubMed

    Hanif, Muhammad Farooq; Iqbal, Beenish; Gilani, Nooman

    2016-06-01

    A case of carbon monoxide poisoning is presented with unusual complications; some of which have not been reported previously. A 48-years-old Asian male presented to the emergency department with dyspnoea, altered state of consciousness and pale discolouration of skin after being locked inside a factory room with burning coal. Patient was in acute respiratory distress. Arterial blood gas analysis showed respiratory acidosis with hypoxaemia. On 3rd day, patient developed dark coloured urine and right upper limb ischaemia. Acute renal failure was diagnosed. A doppler ultrasound showed stenosis of radial and ulnar arteries. 0n 8th day, patient regained consciousness and complained of loss of vision. An MRI of the brain revealed bilateral occipital venous infarcts. Cortical venous infarcts and arterial stenosis are rare complications of acute carbon monoxide poisoning.

  16. The Effect of Water Vapor on Flame Velocity in Equivalent Carbon Monoxide and Oxygen Mixtures

    NASA Technical Reports Server (NTRS)

    Fiock, Ernest F; King, H Kendall

    1936-01-01

    This report presents the results of an investigation to study the effect of water vapor upon the spatial speed of flame in equivalent mixtures of carbon monoxide and oxygen at various total pressures from 100 to 780 mm.hg. These results show that, within this pressure range, an increase in flame speed is produced by increasing the mole fraction of water vapor at least as far as saturation at 25 degrees c., and that the rate of this increase is greater the higher the pressure. It is evident that water vapor plays an important part in the explosive oxidation of carbon monoxide; the need for further experimental evidence as to the nature of its action is indicated.

  17. Cytoprotection by inhaled carbon monoxide before cardiopulmonary bypass in preclinical models.

    PubMed

    Loop, Torsten; Schlensak, Christian; Goebel, Ulrich

    2012-05-01

    Although a potentially toxic gaseous molecule, carbon monoxide recently gains rising scientifically and clinical interest as its beneficial effects and mechanisms of action are defined substantially in various in vitro and in vivo experiments. Its anti-inflammatory, anti-apoptotic and anti-proliferative properties but its increasing impact concerning numerous disease models in means of protection, well describe this gas as a new and challenging therapeutic alternative. In this review, we focus on the extensively analyzed advantageous value of pre- and postconditioning with inhaled carbon monoxide in the context of lung and kidney injury, induced by the low perfusion during and after cardiopulmonary bypass. Mechanisms like the heat shock response as well as an expanded view regarding toxicity and side effects are described broadly.

  18. Remote detection of carbon monoxide by FTIR for simulating field detection in industrial process

    NASA Astrophysics Data System (ADS)

    Gao, Qiankun; Liu, Wenqing; Zhang, Yujun; Gao, Mingguang; Xu, Liang; Li, Xiangxian; Jin, Ling

    2016-10-01

    In order to monitor carbon monoxide in industrial production, we developed a passive gas radiation measurement system based on Fourier transform infrared spectroscopy and carried out infrared radiation measurement experiment of carbon monoxide detection in simulated industrial production environment by this system. The principle, condition, device and data processing method of the experiment are introduced in this paper. In order to solve the problem of light path jitter in the actual industrial field, we simulated the noise in the industrial environment. We combine the advantages of MATHEMATICA software in the aspects of graph processing and symbolic computation to data processing to improve the signal noise ratio and noise suppression. Based on the HITRAN database, the nonlinear least square fitting method was used to calculate the concentration of the CO spectra before and after the data processing. By comparing the calculated concentration, the data processed by MATHEMATICA is reliable and necessary in the industrial production environment.

  19. The distribution of middle tropospheric carbon monoxide during early October 1984

    NASA Technical Reports Server (NTRS)

    Reichle, Henry G., Jr.; Connors, Vickie S.; Wallio, H. Andrew; Holland, J. Alvin; Sherrill, Robert T.; Casas, Joseph C.; Gormsen, Barbara B.

    1989-01-01

    The distribution of middle tropospheric carbon monoxide measure by the Measurement of Air Pollution from Satellites (MAPS) instrument carried aboard the space shuttle is reported. The data represent average mixing ratios in the middle troposphere and are presented in the form of maps that show the carbon monoxide mixing ratios averaged for 6 days of the mission. Comparisons with concurrent, direct measurements taken aboard aircraft show that the inferred concentrations are systematically low by from 20 to 40 percent depending upon which direct measurement calibration standard is used. The data show that there are very large CO sources resulting from biomass burning over South America and southern Africa. Measured mixing ratios were high over northeast Asia and were highly variable over Europe.

  20. Nano-crystalline porous tin oxide film for carbon monoxide sensing

    NASA Technical Reports Server (NTRS)

    Liu, Chung-Chiun (Inventor); Savinell, Robert F. (Inventor); Jin, Zhihong (Inventor)

    2000-01-01

    A tin oxide sol is deposited on platinum electrodes (12) of a sensor (10). The sol is calcined at a temperature of 500 to 800.degree. C. to produce a thin film of tin oxide with a thickness of about 150 nm to 2 .mu. and having a nano-crystalline structure with good stability. The sensor rapidly detects reducing gases, such as carbon monoxide, or hydrocarbons and organic vapors. Sensors using films calcined at around 700.degree. C. have high carbon monoxide selectivity with a response time of around 4 minutes and a recovery time of 1 minute, and therefore provide good detection systems for detection of trace amounts of pollutants such as toxic and flammable gases in homes, industrial settings, and hospitals.

  1. Contributions of distinct gold species to catalytic reactivity for carbon monoxide oxidation

    PubMed Central

    Guo, Li-Wen; Du, Pei-Pei; Fu, Xin-Pu; Ma, Chao; Zeng, Jie; Si, Rui; Huang, Yu-Ying; Jia, Chun-Jiang; Zhang, Ya-Wen; Yan, Chun-Hua

    2016-01-01

    Small-size (<5 nm) gold nanostructures supported on reducible metal oxides have been widely investigated because of the unique catalytic properties they exhibit in diverse redox reactions. However, arguments about the nature of the gold active site have continued for two decades, due to the lack of comparable catalyst systems with specific gold species, as well as the scarcity of direct experimental evidence for the reaction mechanism under realistic working conditions. Here we report the determination of the contribution of single atoms, clusters and particles to the oxidation of carbon monoxide at room temperature, by the aid of in situ X-ray absorption fine structure analysis and in situ diffuse reflectance infrared Fourier transform spectroscopy. We find that the metallic gold component in clusters or particles plays a much more critical role as the active site than the cationic single-atom gold species for the room-temperature carbon monoxide oxidation reaction. PMID:27848964

  2. Electricity generation from carbon monoxide and syngas in a microbial fuel cell.

    PubMed

    Hussain, Abid; Guiot, Serge R; Mehta, Punita; Raghavan, Vijaya; Tartakovsky, Boris

    2011-05-01

    Electricity generation in microbial fuel cells (MFCs) has been a subject of significant research efforts. MFCs employ the ability of electricigenic bacteria to oxidize organic substrates using an electrode as an electron acceptor. While MFC application for electricity production from a variety of organic sources has been demonstrated, very little research on electricity production from carbon monoxide and synthesis gas (syngas) in an MFC has been reported. Although most of the syngas today is produced from non-renewable sources, syngas production from renewable biomass or poorly degradable organic matter makes energy generation from syngas a sustainable process, which combines energy production with the reprocessing of solid wastes. An MFC-based process of syngas conversion to electricity might offer a number of advantages such as high Coulombic efficiency and biocatalytic activity in the presence of carbon monoxide and sulfur components. This paper presents a discussion on microorganisms and reactor designs that can be used for operating an MFC on syngas.

  3. Effect of cigarette smoke, nicotine, and carbon monoxide on the permeability of the arterial wall

    SciTech Connect

    Allen, D.R.; Browse, N.L.; Rutt, D.L.; Butler, L.; Fletcher, C.

    1988-01-01

    The association between cigarette smoking and the development of atherosclerosis is well established, but the mechanism that makes cigarettes such a potent risk factor is not understood. There is normally a constant insudation of plasma macromolecules into the arterial wall. Fibrinogen and lipids are two of the large molecules involved in atherosclerosis. Therefore, we studied the effect of cigarette smoke, nicotine, and carbon monoxide on the permeability of the canine arterial wall to /sup 125/I-labeled fibrinogen. The results show that inhaled cigarette smoke significantly and rapidly increases the permeability of the arterial wall to fibrinogen and that this effect can be produced with carbon monoxide alone but not with intravenous nicotine.

  4. A nine-atom rhodium–aluminum oxide cluster oxidizes five carbon monoxide molecules

    PubMed Central

    Li, Xiao-Na; Zhang, Hua-Min; Yuan, Zhen; He, Sheng-Gui

    2016-01-01

    Noble metals can promote the direct participation of lattice oxygen of very stable oxide materials such as aluminum oxide, to oxidize reactant molecules, while the fundamental mechanism of noble metal catalysis is elusive. Here we report that a single atom of rhodium, a powerful noble metal catalyst, can promote the transfer of five oxygen atoms to oxidize carbon monoxide from a nine-atom rhodium–aluminum oxide cluster. This is a sharp improvement in the field of cluster science where the transfer of at most two oxygen atoms from a doped cluster is more commonly observed. Rhodium functions not only as the preferred trapping site to anchor and oxidize carbon monoxide by the oxygen atoms in direct connection with rhodium but also the primarily oxidative centre to accumulate the large amounts of electrons and the polarity of rhodium is ultimately transformed from positive to negative. PMID:27094921

  5. Carbon monoxide and oxygen combustion experiments: A demonstration of Mars in situ propellants

    NASA Technical Reports Server (NTRS)

    Linne, Diane L.

    1991-01-01

    The feasibility of using carbon monoxide and oxygen as rocket propellants was examined both experimentally and theoretically. The steady-state combustion of carbon monoxide and oxygen was demonstrated for the first time in a subscale rocket engine. Measurements of experimental characteristic velocity, vacuum specific impulse, and thrust coefficient efficiency were obtained over a mixture ratio range of 0.30 to 2.0 and a chamber pressures of 1070 and 530 kPa. The theoretical performance of the propellant combination was studied parametrically over the same mixture ratio range. In addition to one dimensional ideal performance predictions, various performance reduction mechanisms were also modeled, including finite-rate kinetic reactions, two-dimensional divergence effects and viscous boundary layer effects.

  6. Some effects of argon and helium upon explosions of carbon monoxide and oxygen

    NASA Technical Reports Server (NTRS)

    Fiock, Ernst F; Roeder, Carl H

    1937-01-01

    Report presents the results of an investigation conducted to study the effects of the inert gases, argon and helium, upon flame speed and expansion ratio in exploding mixtures of carbon monoxide, oxygen and water.For the particular gas mixtures investigated the results show that: (1) With the possible exception of helium in small amounts the addition of inert gas always produces decreased flame speed and expansion ratio; (2) like volumes of argon and helium have very different effects upon flame speed but practically the same effect upon expansion ratio; and (3) the difference in the effect of these two gases upon speed is independent of the ratio of carbon monoxide to oxygen. A discussion of some possible modes by which inert gases may produce the observed effects is included.

  7. Measurements of the global distribution of carbon monoxide in the troposphere

    NASA Astrophysics Data System (ADS)

    Hinton, R. R.

    1982-07-01

    Carbon monoxide and methane grab samples were obtained simultaneously with ozone, aerosol, nitric oxide and DACOM CO measurements. Eighty grab samples were collected at various altitudes up to 19,000 ft. along a north-south flight path from Wallops Flight Center, VA to 11 N. CO and CH were analyzed by flame ionization gas chromatography with cryogenic preconcentration. The relationship between CO and O3 concentrated is examined. A comparative analysis between trends in aerosol and CO concentration is performed.

  8. Carbon monoxide poisoning in children riding in the back of pickup trucks

    SciTech Connect

    Hampson, N.B.; Norkool, D.M. )

    1992-01-22

    The purpose of this study is to describe the case characteristics of a series of children poisoned with carbon monoxide while traveling in the back of pickup trucks. Pediatric cases referred for treatment of carbon monoxide poisoning with hyperbaric oxygen between 1986 and 1991 were reviewed. Those cases that occurred during travel in the back of pickup trucks were selected. Clinical follow-up by telephone interview ranged from 2 to 55 months. The study took place in a private, urban, tertiary care center in Seattle, Wash. Twenty children ranging from 4 to 16 years of age were studies. All patients were treated with hyperbaric oxygen. Of 68 pediatric patients treated for accidental carbon monoxide poisoning, 20 cases occurred as children rode in the back of pickup trucks. In 17 of these, the children were riding under a rigid closed canopy on the rear of the truck, while three episodes occurred as children rode beneath a tarpaulin. Average carboxyhemoglobin level on emergency department presentation was 18.2% {plus minus} 2.4% (mean {plus minus} SEM; range, 1.6% to 37.0%). Loss of consciousness occurred in 15 of the 20 children. One child died of cerebral edema, one had permanent neurologic deficits, and 18 had no recognizable sequelae related to the episode. In all cases, the truck exhaust system had a previously known leak or a tail pipe that exited at the rear rather than at the side of the pickup truck. Carbon monoxide poisoning is a significant hazard for children who ride in the back of pickup trucks. If possible, this practice should be avoided.

  9. Measurements of the global distribution of carbon monoxide in the troposphere

    NASA Technical Reports Server (NTRS)

    Hinton, R. R.

    1982-01-01

    Carbon monoxide and methane grab samples were obtained simultaneously with ozone, aerosol, nitric oxide and DACOM CO measurements. Eighty grab samples were collected at various altitudes up to 19,000 ft. along a north-south flight path from Wallops Flight Center, VA to 11 N. CO and CH were analyzed by flame ionization gas chromatography with cryogenic preconcentration. The relationship between CO and O3 concentrated is examined. A comparative analysis between trends in aerosol and CO concentration is performed.

  10. Catalytic hydrogenation of carbon monoxide over nanostructured perovskite-like gadolinium and strontium ferrites

    NASA Astrophysics Data System (ADS)

    Sheshko, T. F.; Serov, Yu. M.; Dement'eva, M. V.; Shul'ga, A.; Chislova, I. V.; Zvereva, I. A.

    2016-05-01

    The catalytic properties of perovskite-like ferrites (A n + 1B n O3 n + 1, where n = 1, 2, 3, …, ∞; A = Gd, Sr; and B = Fe) synthesized via ceramic and sol-gel technology in the hydrogenation of carbon monoxide are studied. The interrelation between catalytic activity, selectivity to olefins and synthetic methods for complex oxide preparation, the number of perovskite layers, crystallite size, composition, and the valence state of iron is established.

  11. P-chiral phosphine-sulfonate/palladium-catalyzed asymmetric copolymerization of vinyl acetate with carbon monoxide.

    PubMed

    Nakamura, Akifumi; Kageyama, Takeharu; Goto, Hiroki; Carrow, Brad P; Ito, Shingo; Nozaki, Kyoko

    2012-08-01

    Utilization of palladium catalysts bearing a P-chiral phosphine-sulfonate ligand enabled asymmetric copolymerization of vinyl acetate with carbon monoxide. The obtained γ-polyketones have head-to-tail and isotactic polymer structures. The origin of the regio- and stereoregularities was elucidated by stoichiometric reactions of acylpalladium complexes with vinyl acetate. The present report for the first time demonstrates successful asymmetric coordination-insertion (co)polymerization of vinyl acetate.

  12. Correlating benzene, total hydrocarbon and carbon monoxide emissions from wood-fired boilers

    SciTech Connect

    Hubbard, A.J.; Grande, D.E.; Berens, J.R.; Piotrowski, J.

    1997-12-31

    Hazardous air pollutants, including benzene, are generated by the incomplete combustion of fuels. Organic compound emissions, which are generally products of incomplete combustion, are reduced by promoting high quality combustion, for example by controlling furnace exit temperatures and establishing minimum residence times. Monitoring carbon monoxide (CO) emissions is important since the amount of carbon monoxide emitted represents the quality of combustion which in turn represents the amount of hazardous air pollutants being generated. Total hydrocarbon (THC) emissions are also related to the quality of combustion. Recently the Wisconsin Department of Natural Resources (DNR) measured the benzene and total hydrocarbon emissions from two large industrial wood fired boilers. These boilers are located at Tenneco Packaging, a container board manufacturing facility in northern Wisconsin. Temperature, oxygen and carbon monoxide concentrations were sampled continuously by Tenneco Packaging`s emission monitoring system. The Department`s team used an organic vapor analyzer to continuously measure concentrations of total hydrocarbons (THC). The Department`s team also used a modified USEPA Method 18 sampling train to capture organic vapors for subsequent analysis by gas chromatography. The data show correlations between benzene and carbon monoxide, and between benzene and THC concentrations. The emissions sampling occurred both upstream of the particulate emissions control system as well as at the stack. The CO variations during actual boiler operation appeared to be well correlated with changes in boiler steam load. That is, increases in CO generally accompanied a change, either up or down, in boiler load. Lower concentrations of CO were associated with stable combustion, as indicated by periods of constant or nearly constant boiler load.

  13. Relation of Hydrogen and Methane to Carbon Monoxide in Exhaust Gases from Internal-Combustion Engines

    NASA Technical Reports Server (NTRS)

    Gerrish, Harold C; Tessmann, Arthur M

    1935-01-01

    The relation of hydrogen and methane to carbon monoxide in the exhaust gases from internal-combustion engines operating on standard-grade aviation gasoline, fighting-grade aviation gasoline, hydrogenated safety fuel, laboratory diesel fuel, and auto diesel fuel was determined by analysis of the exhaust gases. Two liquid-cooled single-cylinder spark-ignition, one 9-cylinder radial air-cooled spark-ignition, and two liquid-cooled single-cylinder compression-ignition engines were used.

  14. A Computer Model for Evaluating the Effects on Fighting Vehicle Crewmembers of Exposure to Carbon Monoxide Emissions.

    DTIC Science & Technology

    1980-01-01

    SUPPLEMENTARY NOTES Is. KEY WORDS (Continue on reverse ede If neceseay id Identify by block number) Carbon Monoxide (CO) Computer Program Carboxyhemoglobin ...several researchers, which predicts the instantaneous amount of carboxyhemoglobin (COHb) in the blood of a person based upon the amount of carbon monoxide...developed from an empirical equation (derived from reference I and detailed in reference 3) which predicts the amount of carboxyhemoglobin (COHb) in

  15. Mortality and hospital admission rates for unintentional nonfire-related carbon monoxide poisoning across Canada: a trend analysis

    PubMed Central

    Weichenthal, Scott; Wong, Joan; Smith-Doiron, Marc; Dugandzic, Rose; Kosatsky, Tom

    2015-01-01

    Background The epidemiology of mortality and morbidity from carbon monoxide poisoning in Canada has received little attention. Our objective was to evaluate trends in mortality and hospital admission rates for unintentional nonfire-related carbon monoxide poisoning across Canada. Methods Age- and sex-standardized mortality (1981–2009) and hospital admission (1995–2010) rates by age group, sex and site of carbon monoxide exposure were calculated for each province and for all of Canada. We quantified the long-term trends by calculating the average annual percent change. Multivariable Poisson regression was used to estimate incidence rate ratios (IRRs) of carbon monoxide poisoning across age groups, sex and month of occurrence. Results In Canada, there were 1808 unintentional nonfire-related carbon monoxide poisoning deaths between 1981 and 2009 and 1984 admissions to hospital between 1995 and 2010. Average annual decreases of 3.46% (95% confidence interval [CI] –4.59% to –2.31%) and 5.83% (95% CI –7.79% to –3.83%) were observed for mortality and hospital admission rates, respectively. Mortality (IRR 5.31, 95% CI 4.57 to 6.17) and hospital admission (IRR 2.77, 95% CI 2.51 to 3.03) rates were elevated in males compared with females. Decreased trends in the rates were observed for all sites of carbon monoxide exposure, but the magnitude of this decrease was lowest in residential environments. Deaths and admissions to hospital were most frequent from September to April, with peaks in December and January. Interpretation Mortality and hospital admission rates for unintentional nonfire-related carbon monoxide poisoning in Canada have declined steadily. Continued efforts should focus on reducing carbon monoxide poisoning during the cooler months and in residential environments. PMID:26389101

  16. Variations of Time-to-Incapacitation and Carboxyhemoglobin Values in Rats Exposed to Two Carbon Monoxide Concentrations

    DTIC Science & Technology

    1993-05-01

    variance in ti at two CO concentrations that produce 5- and 35-min ti in rats were determined; blood carboxyhemoglobin ( COHb ) saturation at ti was measured... carboxyhemoglobin conceri- caveats should be applied when making judgments on tration the indicator of carbon monoxide toxicity? the basis of COHb analyses only. In...TIME-TO-INCAPACITATION (tc) VALUES AND CARBOXYHEMOGLOBIN ( COHb ) LEVELS AT INCAPACITATION FOR RATS EXPOSED TO CARBON MONOXIDE (CO) Al Table 1. Data

  17. The origin of carbon monoxide in Neptunes's atmosphere

    NASA Technical Reports Server (NTRS)

    Lodders, K.; Fegley, B., Jr.

    1994-01-01

    The CO abundance in the observable atmosphere of Neptune can be plausibly explained by rapid vertical mixing from the deeper atmosphere if Neptune has a greater complement of water than Uranus. Thermochemical equilibrium and kinetic calculations reveal that Neptune must and Uranus may have about 10 times more oxygen than carbon, whereas for Jupiter and Saturn equal enrichments of carbon and oxygen are satifactory to explain the observed CO abundances by deep vertical mixing. Relative to hydrogen and solar composition, the respective enrichment factors for carbon and oxygen are 41, 440 (Neptune); 32, less than or equal 260 (Uranus); 6.6, 6.6 (Saturn); and 2.8, 2.8 (Jupiter). Because water ice is the most refractory ice among the ices assumed to be present in the outer solar nebula, the most massive H2O enrichment is expected for the outermost planet of this group. Thus, Neptune can indeed be regarded as the 'god of the seas.'

  18. Hemodialysis patients have plasmatic hypercoagulability and decreased fibrinolytic vulnerability: role of carbon monoxide.

    PubMed

    Matika, Ryan W; Nielsen, Vance G; Steinbrenner, Evangelina B; Sussman, Amy N; Madhrira, Machaiah

    2014-01-01

    Chronic hemodialysis is associated with significant thrombophilia. Of interest, hemodialysis patients have increased carboxyhemoglobin (COHb) and exhaled carbon monoxide (CO), signs of upregulated heme oxygenase (Hmox) activity. Given that CO enhances plasmatic coagulation, we determined whether patients requiring chronic hemodialysis had an increase in endogenous CO, plasmatic hypercoagulability and decreased fibrinolytic vulnerability. Carbon monoxide was determined by noninvasive pulse oximetry measurement of COHb. Blood samples were obtained just before hemodialysis. Thrombelastographic methods to assess plasma coagulation kinetics, fibrinolytic kinetics, and formation of carboxyhemefibrinogen (COHF) were used. Hemodialysis patients (n = 45) had abnormally increased COHb concentrations of 2.2 ± 1.9%, indicative of Hmox upregulation. Coagulation and fibrinolytic parameter normal values were determined with normal individual (n = 30) plasma. Thirty-seven patients of the hemodialysis cohort had COHF formation (82.2%, [67.9%-92.0%]; mean, [95% confidence interval]), and many of this group of patients had abnormally great velocity of clot growth (73.3%, [58.1%-85.4%]) and strength (75.6%, [60.5%-87.1%]). Furthermore, over half of COHF positive patients had a hypofibrinolytic state, evidenced by an abnormally prolonged time to maximum rate of lysis (53.3%, [37.9%-68.6%]) and clot lysis time (64.4%, [48.8%-78.1%]). Carbon monoxide enhanced coagulation and diminished fibrinolytic vulnerability in hemodialysis patients. Future investigation of hemodialysis, CO-related thrombophilia is warranted.

  19. New analytical reagents for the determination of sulfur dioxide and carbon monoxide

    SciTech Connect

    Trump, E.L.

    1987-01-01

    Four solid reagent methods were developed for the determination of sulfur dioxide in air, and one method was developed to measure carbon monoxide. When applied to filter paper with acetamide as the humectant and 4-phenylcyclohexanone as a bisulfite absorbent, oxohydroxybis(8-hydroxyquinolinyl-) vanadium (V) changes from yellow to black in the presence of sulfur dioxide. The three other methods, also on a filter paper support, utilized the reduction of bromate to bromine which then changed 3-,3'-, 5-,5'-tetramethylbenzidine from yellow to blue, phenothiazine from white to green, and 4-dimethylamino-4'-,4/double prime/-dimethoxytriphenylmethanol from colorless to red-purple. Quantitative measurements were made by reflectance spectroscopy. The method for carbon monoxide involved the use of tetrakis (acetamide-) Pd(II) ditetrafluoroborate, sodium iodate, and leuco crystal violet all together on a filter paper support. Carbon monoxide reduced the Pd(II)-acetamide complex to metallic palladium. The metallic palladium then reduced iodate to hypoiodous acid, HOI, which, in turn, oxidized leuco crystal violet to crystal violet. The crystal violet color was then measured by reflectance.

  20. Suicidal carbon monoxide poisoning by combining formic acid and sulfuric acid within a confined space.

    PubMed

    Lin, Peter T; Dunn, William A

    2014-01-01

    Suicide by inhalation of carbon monoxide produced by mixing formic acid and sulfuric acid within a confined space is a rare method of suicide. This method is similar to the so-called "detergent suicide" method where an acid-based detergent is mixed with a sulfur source to produce hydrogen sulfide. Both methods produce a toxic gas that poses significant hazards for death investigators, first responders and bystanders. Carbon monoxide is an odorless gas, while hydrogen sulfide has a characteristic rotten eggs odor, so the risks associated with carbon monoxide are potentially greater due to lack of an important warning signal. While detergent suicides have become increasingly common in the USA, suicide with formic acid and sulfuric acid is rare with only three prior cases being reported. Greater awareness of this method among death investigators is warranted because of the special risks of accidental intoxication by toxic gas and the possibility that this method of suicide will become more common in the future.