  1. A compact time-of-flight mass spectrometer for ion source characterization

    SciTech Connect

    Chen, L. Wan, X.; Jin, D. Z.; Tan, X. H.; Huang, Z. X.; Tan, G. B.

    2015-03-15

    A compact time-of-flight mass spectrometer with overall dimension of about 413 × 250 × 414 mm based on orthogonal injection and angle reflection has been developed for ion source characterization. Configuration and principle of the time-of-flight mass spectrometer are introduced in this paper. The mass resolution is optimized to be about 1690 (FWHM), and the ion energy detection range is tested to be between about 3 and 163 eV with the help of electron impact ion source. High mass resolution and compact configuration make this spectrometer useful to provide a valuable diagnostic for ion spectra fundamental research and study the mass to charge composition of plasma with wide range of parameters.

  2. A Design for a Compact Time-of-Flight Mass Spectrometer

    SciTech Connect

    Manard, M.

    2012-10-01

    The design of a prototype, compact time-of-flight (TOF) mass spectrometer (MS) is described. The system primarily consists of an ion acceleration/focusing/steering assembly (AFSA), an 8 cm field-free region, a 4 cm, dual-stage reflectron and a miniature microchannel plate detector. Consequently, the resulting flight length of the system is 12 cm. The system has been designed with the capability to sample directly from atmosphere at ambient pressures. This is accomplished through the use of an electrodynamic ion funnel, housed in an intermediate-vacuum chamber that is coupled to the inlet of the TOF chamber. TOF spectra were obtained using noble gases (Ar, Kr and Xe) as test chemicals. These measured flight times were used to probe the performance of the instrument. A temporal resolution (tflight/Δt) of approximately 125, acquired using 129Xe+, has been measured for the system.

  3. Development of a compact laser-based single photon ionization time-of-flight mass spectrometer

    NASA Astrophysics Data System (ADS)

    Tonokura, Kenichi; Kanno, Nozomu; Yamamoto, Yukio; Yamada, Hiroyuki

    2010-02-01

    We have developed a compact, laser-based, single photon ionization time-of-flight mass spectrometer (SPI-TOF-MS) for on-line monitoring of trace organic species. To obtain the mass spectrum, we use a nearly fragmentation-free SPI technique with 10.5 eV (118 nm) vacuum ultraviolet laser pulses generated by frequency tripling of the third harmonic of an Nd:YAG laser. The instrument can be operated in a linear TOF-MS mode or a reflectron TOF-MS mode in the coaxial design. We designed ion optics to optimize detection sensitivity and mass resolution. For data acquisition, the instrument is controlled using LabVIEW control software. The total power requirement for the vacuum unit, control electronics unit, ion optics, and detection system is approximately 100 W. We achieve a detection limit of parts per billion by volume (ppbv) for on-line trace analysis of several organic compounds. A mass resolution of 800 at about 100 amu is obtained for reflectron TOF-MS mode in a 0.35 m long instrument. The application of on-line monitoring of diesel engine exhaust was demonstrated.

  4. A compact time-of-flight spectrometer for electrofission studies*

    NASA Astrophysics Data System (ADS)

    Heil, R. D.; Drexler, J.; Huber, K.; Kneissl, U.; Mank, G.; Ries, H.; Ströher, H.; Weber, T.; Wilke, W.

    1985-09-01

    A compact time-of-flight spectrometer for measurements of fission fragment distributions is described. The start detector consists of a channel plate arrangement with an electrostatic mirror. The time resolution of PPACs, serving as stop detectors, has been optimized. Velocity distributions of 252Cf fragments and mean velocities are reported. The results are discussed with respect to planned (e, e'f) coincidence experiments at the Mainz microtron.

  5. An integrated time-of-flight versus residual energy subsystem for a compact dual ion composition experiment for space plasmas.

    PubMed

    Desai, M I; Ogasawara, K; Ebert, R W; McComas, D J; Allegrini, F; Weidner, S E; Alexander, N; Livi, S A

    2015-05-01

    We have developed a novel concept for a Compact Dual Ion Composition Experiment (CoDICE) that simultaneously provides high quality plasma and energetic ion composition measurements over 6 decades in ion energy in a wide variety of space plasma environments. CoDICE measures the two critical ion populations in space plasmas: (1) mass and ionic charge state composition and 3D velocity and angular distributions of ∼10 eV/q-40 keV/q plasma ions—CoDICE-Lo and (2) mass composition, energy spectra, and angular distributions of ∼30 keV-10 MeV energetic ions—CoDICE-Hi. CoDICE uses a common, integrated Time-of-Flight (TOF) versus residual energy (E) subsystem for measuring the two distinct ion populations. This paper describes the CoDICE design concept, and presents results of the laboratory tests of the TOF portion of the TOF vs. E subsystem, focusing specifically on (1) investigation of spill-over and contamination rates on the start and stop microchannel plate (MCP) anodes vs. secondary electron steering and focusing voltages, scanned around their corresponding model-optimized values, (2) TOF measurements and resolution and angular resolution, and (3) cross-contamination of the start and stop MCPs' singles rates from CoDICE-Lo and -Hi, and (4) energy resolution of avalanche photodiodes near the lower end of the CoDICE-Lo energy range. We also discuss physical effects that could impact the performance of the TOF vs. E subsystem in a flight instrument. Finally, we discuss advantages of the CoDICE design concept by comparing with capabilities and resources of existing flight instruments.

  6. An integrated time-of-flight versus residual energy subsystem for a compact dual ion composition experiment for space plasmas

    SciTech Connect

    Desai, M. I.; McComas, D. J.; Allegrini, F.; Livi, S. A.; Ogasawara, K.; Ebert, R. W.; Weidner, S. E.; Alexander, N.

    2015-05-15

    We have developed a novel concept for a Compact Dual Ion Composition Experiment (CoDICE) that simultaneously provides high quality plasma and energetic ion composition measurements over 6 decades in ion energy in a wide variety of space plasma environments. CoDICE measures the two critical ion populations in space plasmas: (1) mass and ionic charge state composition and 3D velocity and angular distributions of ∼10 eV/q–40 keV/q plasma ions—CoDICE-Lo and (2) mass composition, energy spectra, and angular distributions of ∼30 keV–10 MeV energetic ions—CoDICE-Hi. CoDICE uses a common, integrated Time-of-Flight (TOF) versus residual energy (E) subsystem for measuring the two distinct ion populations. This paper describes the CoDICE design concept, and presents results of the laboratory tests of the TOF portion of the TOF vs. E subsystem, focusing specifically on (1) investigation of spill-over and contamination rates on the start and stop microchannel plate (MCP) anodes vs. secondary electron steering and focusing voltages, scanned around their corresponding model-optimized values, (2) TOF measurements and resolution and angular resolution, and (3) cross-contamination of the start and stop MCPs’ singles rates from CoDICE-Lo and -Hi, and (4) energy resolution of avalanche photodiodes near the lower end of the CoDICE-Lo energy range. We also discuss physical effects that could impact the performance of the TOF vs. E subsystem in a flight instrument. Finally, we discuss advantages of the CoDICE design concept by comparing with capabilities and resources of existing flight instruments.

  7. A compact time-of-flight SANS instrument optimised for measurements of small sample volumes at the European Spallation Source

    NASA Astrophysics Data System (ADS)

    Kynde, Søren; Hewitt Klenø, Kaspar; Nagy, Gergely; Mortensen, Kell; Lefmann, Kim; Kohlbrecher, Joachim; Arleth, Lise

    2014-11-01

    The high flux at European Spallation Source (ESS) will allow for performing experiments with relatively small beam-sizes while maintaining a high intensity of the incoming beam. The pulsed nature of the source makes the facility optimal for time-of-flight small-angle neutron scattering (ToF-SANS). We find that a relatively compact SANS instrument becomes the optimal choice in order to obtain the widest possible q-range in a single setting and the best possible exploitation of the neutrons in each pulse and hence obtaining the highest possible flux at the sample position. The instrument proposed in the present article is optimised for performing fast measurements of small scattering volumes, typically down to 2×2×2 mm3, while covering a broad q-range from about 0.005 1/Å to 0.5 1/Å in a single instrument setting. This q-range corresponds to that available at a typical good BioSAXS instrument and is relevant for a wide set of biomacromolecular samples. A central advantage of covering the whole q-range in a single setting is that each sample has to be loaded only once. This makes it convenient to use the fully automated high-throughput flow-through sample changers commonly applied at modern synchrotron BioSAXS-facilities. The central drawback of choosing a very compact instrument is that the resolution in terms of δλ / λ obtained with the short wavelength neutrons becomes worse than what is usually the standard at state-of-the-art SANS instruments. Our McStas based simulations of the instrument performance for a set of characteristic biomacromolecular samples show that the resulting smearing effects still have relatively minor effects on the obtained data and can be compensated for in the data analysis. However, in cases where a better resolution is required in combination with the large simultaneous q-range characteristic of the instrument, we show that this can be obtained by inserting a set of choppers.

  8. A compact Ultra-High Vacuum (UHV) compatible instrument for time of flight-energy measurements of slow heavy reaction products

    NASA Astrophysics Data System (ADS)

    Kuznetsov, A. V.; van Veldhuizen, E. J.; Westerberg, L.; Lyapin, V. G.; Aleklett, K.; Loveland, W.; Bondorf, J.; Jakobsson, B.; Whitlow, H. J.; El Bouanani, M.

    2000-10-01

    A compact Ultra-High Vacuum (UHV) compatible instrument for time of flight-energy measurements of slow heavy reaction products from nuclear reactions has been designed and tested at the CELSIUS storage ring in Uppsala. The construction is based on MicroChannel Plate (MCP) time detectors of the electron mirror type and silicon p-i-n diodes, and permits the detectors to be stacked side-by-side to achieve large solid angle coverage. This kind of telescope measures the Time of Flight (ToF) and Energy (E) of the particle from which one can reconstruct mass. The combination of an ultra-thin cluster gas-jet target and thin carbon emitter foils allows one to measure heavy residues down to an energy of ˜35 keV/nucleon from the interactions of 400 MeV/nucleon 16O with natXe gas targets.

  9. Compact Two-step Laser Time-of-Flight Mass Spectrometer for in Situ Analyses of Aromatic Organics on Planetary Missions

    NASA Technical Reports Server (NTRS)

    Getty, Stephanie; Brickerhoff, William; Cornish, Timothy; Ecelberger, Scott; Floyd, Melissa

    2012-01-01

    RATIONALE A miniature time-of-flight mass spectrometer has been adapted to demonstrate two-step laser desorption-ionization (LOI) in a compact instrument package for enhanced organics detection. Two-step LDI decouples the desorption and ionization processes, relative to traditional laser ionization-desorption, in order to produce low-fragmentation conditions for complex organic analytes. Tuning UV ionization laser energy allowed control ofthe degree of fragmentation, which may enable better identification of constituent species. METHODS A reflectron time-of-flight mass spectrometer prototype measuring 20 cm in length was adapted to a two-laser configuration, with IR (1064 nm) desorption followed by UV (266 nm) postionization. A relatively low ion extraction voltage of 5 kV was applied at the sample inlet. Instrument capabilities and performance were demonstrated with analysis of a model polycyclic aromatic hydrocarbon, representing a class of compounds important to the fields of Earth and planetary science. RESULTS L2MS analysis of a model PAH standard, pyrene, has been demonstrated, including parent mass identification and the onset o(tunable fragmentation as a function of ionizing laser energy. Mass resolution m/llm = 380 at full width at half-maximum was achieved which is notable for gas-phase ionization of desorbed neutrals in a highly-compact mass analyzer. CONCLUSIONS Achieving two-step laser mass spectrometry (L2MS) in a highly-miniature instrument enables a powerful approach to the detection and characterization of aromatic organics in remote terrestrial and planetary applications. Tunable detection of parent and fragment ions with high mass resolution, diagnostic of molecular structure, is possible on such a compact L2MS instrument. Selectivity of L2MS against low-mass inorganic salt interferences is a key advantage when working with unprocessed, natural samples, and a mechanism for the observed selectivity is presented.

  10. Characterization of a compact filament-driven multicusp ion source for low energy time-of-flight Rutherford backscattering spectrometry application

    NASA Astrophysics Data System (ADS)

    Dangtip, S.; Junphong, P.; Ano, V.; Lekprasert, B.; Suwannakachorn, D.; Thongnopparat, N.; Vilaithong, T.

    2004-05-01

    Because of the limited pulse height energy resolution of a detector, conventional Rutherford backscattering spectrometry (RBS) requires an energy of the incident α particle to be in the MeV region. At Chiang Mai University we have researched the possibility of utilizing a 280 keV nanosecond pulse of helium ions for RBS applications. We have chosen a compact filament-driven multicusp ion source of 2.6 cm in diameter and 8 cm in length being investigated for the time-of-flight RBS applications. In this article, we present the general ion source performance using helium, nitrogen, and argon for generating the discharge plasma. The general ion source characteristics have been measured and analyzed. The measurements also include the extractable ion current and the ion beam emittance. We have performed beam extraction calculations with a computer simulation code KOBRA. Results of the measurements and calculations will be presented and discussed.

  11. A compact, high-density gamma-detection module for Time-of-Flight measurements in PET applications

    NASA Astrophysics Data System (ADS)

    Sacco, I.; Dohle, R.; Fischer, P.; Piemonte, C.; Ritzert, M.

    2016-07-01

    We present a very compact γ-detection module primarily designed for PET applications. On a total area of about 30 × 30mm2, 144 SiPM photodetectors coupled to scintillator crystals are read out individually with fast timing ASICs. The core of the module is a LTCC ceramic substrate with internal water channels for efficient and stable liquid cooling. The top side of the LTCC is covered by 12×12 SiPMs in a regular pitch of 2.5 mm. The SiPMs are designed in the RGB-HD technology from FBK with a single cell size of 25 × 25 μm2, very low dark-count rate and stable performance over a wide temperature range from 0 to 20 °C. The readout of the SiPMs is done with 4 specialized PETA5 ASICs flip-chip mounted to the bottom side of the substrate. Each chip has 36 readout channels (available in single or differential ended configuration) with self-triggered hit detection, a very low noise discriminator, signal amplitude integration and digitization, a TDC with 50 ps binwidth, neighbor logic and fast veto mechanisms. The full height of the assembly, including the connector to the main readout board, is less than 1 cm. In a 1:1 coupling configuration with 10 mm high LYSO scintillator arrays for detection of 511 keV gammas, the module has already reached 205 ps CRT time resolution (FWHM in coincidence between channels on two different modules), sufficient for ToF operation in PET. The module design, details on chip operation and latest results with LYSO arrays are described.

  12. Preliminary energy-filtering neutron imaging with time-of-flight method on PKUNIFTY: A compact accelerator based neutron imaging facility at Peking University

    NASA Astrophysics Data System (ADS)

    Wang, Hu; Zou, Yubin; Wen, Weiwei; Lu, Yuanrong; Guo, Zhiyu

    2016-07-01

    Peking University Neutron Imaging Facility (PKUNIFTY) works on an accelerator-based neutron source with a repetition period of 10 ms and pulse duration of 0.4 ms, which has a rather low Cd ratio. To improve the effective Cd ratio and thus improve the detection capability of the facility, energy-filtering neutron imaging was realized with the intensified CCD camera and time-of-flight (TOF) method. Time structure of the pulsed neutron source was firstly simulated with Geant4, and the simulation result was evaluated with experiment. Both simulation and experiment results indicated that fast neutrons and epithermal neutrons were concentrated in the first 0.8 ms of each pulse period; meanwhile in the period of 0.8-2.0 ms only thermal neutrons existed. Based on this result, neutron images with and without energy filtering were acquired respectively, and it showed that detection capability of PKUNIFTY was improved with setting the exposure interval as 0.8-2.0 ms, especially for materials with strong moderating capability.

  13. A Compact Tandem Two-Step Laser Time-of-Flight Mass Spectrometer for In Situ Analysis of Non-Volatile Organics on Planetary Surfaces

    NASA Technical Reports Server (NTRS)

    Getty, Stephanie A.; Brinckerhoff, William B.; Li, Xiang; Elsila, Jamie; Cornish, Timothy; Ecelberger, Scott; Wu, Qinghao; Zare, Richard

    2014-01-01

    Two-step laser desorption mass spectrometry is a well suited technique to the analysis of high priority classes of organics, such as polycyclic aromatic hydrocarbons, present in complex samples. The use of decoupled desorption and ionization laser pulses allows for sensitive and selective detection of structurally intact organic species. We have recently demonstrated the implementation of this advancement in laser mass spectrometry in a compact, flight-compatible instrument that could feasibly be the centerpiece of an analytical science payload as part of a future spaceflight mission to a small body or icy moon.

  14. Time of flight mass spectrometer

    DOEpatents

    Ulbricht, Jr., William H.

    1984-01-01

    A time-of-flight mass spectrometer is described in which ions are desorbed from a sample by nuclear fission fragments, such that desorption occurs at the surface of the sample impinged upon by the fission fragments. This configuration allows for the sample to be of any thickness, and eliminates the need for complicated sample preparation.

  15. Single photon ionization (SPI) via incoherent VUV-excimer light: robust and compact time-of-flight mass spectrometer for on-line, real-time process gas analysis.

    PubMed

    Mühlberger, F; Wieser, J; Ulrich, A; Zimmermann, R

    2002-08-01

    Fast on-line detection of organic compounds from complex mixtures, such as industrial process gas streams, require selective and sensitive analytical methods. One feasible approach for this purpose is the use of mass spectrometry (MS) with a selective and soft (fragment-free) ionization technique, such as chemical ionization (CI) or photo ionization (PI). Single photon ionization (SPI) with vacuum ultraviolet (VUV) light is a particularly sof tionization technique, well-suited for detection of both aromatic and aliphatic species. Problematic, however, is the generation of the VUV light. In general, the vacuum ultraviolet (VUV) light sources for SPI-MS are based either on lasers (e.g., 118-nm radiation generated by frequency-tripling of the third harmonic of a Nd:YAG laser) or on conventional VUV lamps, such as deuterium lamps. Althoughthe laser-based techniques are very sophisticated and expensive, the conventional lamps have serious drawbacks regarding their optical parameters, such as low-output power, low spectral power density, and broad emission bands. In this work, a novel excimer VUV light source, in which an electron beam is used to form rare gas excimer species, is used. The excimer VUV light sourceproduces brilliant and intense VUV light. The novel VUV light source was coupled to a compact and mobile time-of-flight mass spectrometer (TOFMS). A special interface design, including optical (VUV optics) as well as electronic measures (e.g., pulsed ion extraction) was realized. The use of the excimer VUV lamp for SPI will allow the realization of very compact, rugged, and sensitive SPI-TOFMS devices, which preferably will be adapted for process analytical application or monitoring issues (e.g., chemical warfare detection). The excimer VUV-lamp technology delivers VUV light with a good beam quality and high-output power at low costs. Furthermore, it allows changing the emitted wavelength as well as the bandwidth of the excimer VUV lamp in t he 100-200-nm region

  16. Time-of-flight measurements

    SciTech Connect

    Atwood, W.B.

    1980-10-01

    Time of flight (TOF) measurements are used in high energy particle physics experiments to: (1) distinguish background from events and (2) identify particle types. An example of background separation is shown. These data come from a coincidence electro-production experiment performed at SLAC. The reaction being studied was e + p ..-->.. e' + p' + X where the e(p) stand for an initial and detected electron (proton) and X is a produced but undetected final state with a mass in the rho meson region. The relative time between the detection of an electron and a proton in two of the spectrometers in End Station A is plotted. Data for two different kinematic settings taken in the experiment are shown. The time resolution has been partially corrected for the various flight paths through the instruments and the difference in time resolutions between the two settings results mainly from the incompleteness of this correction. The signal height above the background depends on the time resolution, ..delta.. tau. The chance background is proportional to the product of the electron counting rate, the proton counting rate, and ..delta.. tau. Smaller ..delta.. tau means that higher electron and proton counting rates may be tolerated and result in a similar signal-to-noise ratio.

  17. Inexpensive Time-of-Flight Velocity Measurements.

    ERIC Educational Resources Information Center

    Everett, Glen E.; Wild, R. L.

    1979-01-01

    Describes a circuit designed to measure time-of-flight velocity and shows how to use it to determine bullet velocity in connection with the ballistic pendulum demonstration of momentum conservation. (Author/GA)

  18. Time-of-flight radio location system

    DOEpatents

    McEwan, Thomas E.

    1996-01-01

    A bi-static radar configuration measures the direct time-of-flight of a transmitted RF pulse and is capable of measuring this time-of-flight with a jitter on the order of about one pico-second, or about 0.01 inch of free space distance for an electromagnetic pulse over a range of about one to ten feet. A transmitter transmits a sequence of electromagnetic pulses in response to a transmit timing signal, and a receiver samples the sequence of electromagnetic pulses with controlled timing in response to a receive timing signal, and generates a sample signal in response to the samples. A timing circuit supplies the transmit timing signal to the transmitter and supplies the receive timing signal to the receiver. The receive timing signal causes the receiver to sample the sequence of electromagnetic pulses such that the time between transmission of pulses in the sequence and sampling by the receiver sweeps over a range of delays. The receive timing signal sweeps over the range of delays in a sweep cycle such that pulses in the sequence are sampled at the pulse repetition rate, and with different delays in the range of delays to produce a sample signal representing magnitude of a received pulse in equivalent time. Automatic gain control circuitry in the receiver controls the magnitude of the equivalent time sample signal. A signal processor analyzes the sample signal to indicate the time-of-flight of the electromagnetic pulses in the sequence.

  19. Time-of-flight radio location system

    DOEpatents

    McEwan, T.E.

    1996-04-23

    A bi-static radar configuration measures the direct time-of-flight of a transmitted RF pulse and is capable of measuring this time-of-flight with a jitter on the order of about one pico-second, or about 0.01 inch of free space distance for an electromagnetic pulse over a range of about one to ten feet. A transmitter transmits a sequence of electromagnetic pulses in response to a transmit timing signal, and a receiver samples the sequence of electromagnetic pulses with controlled timing in response to a receive timing signal, and generates a sample signal in response to the samples. A timing circuit supplies the transmit timing signal to the transmitter and supplies the receive timing signal to the receiver. The receive timing signal causes the receiver to sample the sequence of electromagnetic pulses such that the time between transmission of pulses in the sequence and sampling by the receiver sweeps over a range of delays. The receive timing signal sweeps over the range of delays in a sweep cycle such that pulses in the sequence are sampled at the pulse repetition rate, and with different delays in the range of delays to produce a sample signal representing magnitude of a received pulse in equivalent time. Automatic gain control circuitry in the receiver controls the magnitude of the equivalent time sample signal. A signal processor analyzes the sample signal to indicate the time-of-flight of the electromagnetic pulses in the sequence. 7 figs.

  20. Time-of-flight radio location system

    DOEpatents

    McEwan, Thomas E.

    1997-01-01

    A bi-static radar configuration measures the direct time-of-flight of a transmitted RF pulse and is capable of measuring this time-of-flight with a jitter on the order of about one pico-second, or about 0.01 inch of free space distance for an electromagnetic pulse over a range of about one to ten feet. A transmitter transmits a sequence of electromagnetic pulses in response to a transmit timing signal, and a receiver samples the sequence of electromagnetic pulses with controlled timing in response to a receive timing signal, and generates a sample signal in response to the samples. A timing circuit supplies the transmit timing signal to the transmitter and supplies the receive timing signal to the receiver. The receive timing signal causes the receiver to sample the sequence of electromagnetic pulses such that the time between transmission of pulses in the sequence and sampling by the receiver sweeps over a range of delays. The receive timing signal sweeps over the range of delays in a sweep cycle such that pulses in the sequence are sampled at the pulse repetition rate, and with different delays in the range of delays to produce a sample signal representing magnitude of a received pulse in equivalent time. Automatic gain control circuitry in the receiver controls the magnitude of the equivalent time sample signal. A signal processor analyzes the sample signal to indicate the time-of-flight of the electromagnetic pulses in the sequence. The sample signal in equivalent time is passed through an envelope detection circuit, formed of an absolute value circuit followed by a low pass filter, to convert the sample signal to a unipolar signal to eliminate effects of antenna misorientation.

  1. Time-of-flight radio location system

    DOEpatents

    McEwan, T.E.

    1997-08-26

    A bi-static radar configuration measures the direct time-of-flight of a transmitted RF pulse and is capable of measuring this time-of-flight with a jitter on the order of about one pico-second, or about 0.01 inch of free space distance for an electromagnetic pulse over a range of about one to ten feet. A transmitter transmits a sequence of electromagnetic pulses in response to a transmit timing signal, and a receiver samples the sequence of electromagnetic pulses with controlled timing in response to a receive timing signal, and generates a sample signal in response to the samples. A timing circuit supplies the transmit timing signal to the transmitter and supplies the receive timing signal to the receiver. The receive timing signal causes the receiver to sample the sequence of electromagnetic pulses such that the time between transmission of pulses in the sequence and sampling by the receiver sweeps over a range of delays. The receive timing signal sweeps over the range of delays in a sweep cycle such that pulses in the sequence are sampled at the pulse repetition rate, and with different delays in the range of delays to produce a sample signal representing magnitude of a received pulse in equivalent time. Automatic gain control circuitry in the receiver controls the magnitude of the equivalent time sample signal. A signal processor analyzes the sample signal to indicate the time-of-flight of the electromagnetic pulses in the sequence. The sample signal in equivalent time is passed through an envelope detection circuit, formed of an absolute value circuit followed by a low pass filter, to convert the sample signal to a unipolar signal to eliminate effects of antenna misorientation. 8 figs.

  2. Time-of-flight Fourier UCN spectrometer

    NASA Astrophysics Data System (ADS)

    Kulin, G. V.; Frank, A. I.; Goryunov, S. V.; Kustov, D. V.; Geltenbort, P.; Jentschel, M.; Lauss, B.; Schmidt-Wellenburg, P.

    2016-05-01

    We describe a new time-of-flight Fourier spectrometer for investigation of UCN diffraction by a moving grating. The device operates in the regime of a discrete set of modulation frequencies. The results of the first experiments show that the spectrometer may be used for obtaining UCN energy spectra in the energy range of 60 - 200 neV with a resolution of about 5 neV. The accuracy of determination of the line position was estimated to be several units of 10-10 eV.

  3. The TORCH time-of-flight detector

    NASA Astrophysics Data System (ADS)

    Harnew, N.; Brook, N.; Castillo García, L.; Cussans, D.; Föhl, K.; Forty, R.; Frei, C.; Gao, R.; Gys, T.; Piedigrossi, D.; Rademacker, J.; Ros Garcia, A.; van Dijk, M.

    2016-07-01

    The TORCH time-of-flight detector is being developed to provide particle identification between 2 and 10 GeV/c momentum over a flight distance of 10 m. TORCH is designed for large-area coverage, up to 30 m2, and has a DIRC-like construction. The goal is to achieve a 15 ps time-of-flight resolution per incident particle by combining arrival times from multiple Cherenkov photons produced within quartz radiator plates of 10 mm thickness. A four-year R&D programme is underway with an industrial partner (Photek, UK) to produce 53×53 mm2 Micro-Channel Plate (MCP) detectors for the TORCH application. The MCP-PMT will provide a timing accuracy of 40 ps per photon and it will have a lifetime of up to at least 5 Ccm-2 of integrated anode charge by utilizing an Atomic Layer Deposition (ALD) coating. The MCP will be read out using charge division with customised electronics incorporating the NINO chipset. Laboratory results on prototype MCPs are presented. The construction of a prototype TORCH module and its simulated performance are also described.

  4. The CDF Time of Flight Detector

    SciTech Connect

    S. Cabrera et al.

    2004-01-06

    A new Time of Flight (TOF) detector based on scintillator bars with fine-mesh photomultipliers at both ends has been in operation since 2001 in the CDF experiment. With a design resolution of 100 ps, the TOF can provide separation between K{sup +-} and {pi}{sup +-} in p{bar p} collisions at the 2{omega} level for low momentum, which enhances b flavor tagging capabilities. Because of its very fast response, the TOF is an excellent triggering device, and it is used to trigger on highly ionizing particles, multiple minimum ionizing particles and cosmic rays. Particle identification is achieved by comparing the time-of-flight of the particle measured by the TOF to the time expected for a given mass hypothesis. In order to obtain the resolution necessary for particle ID, optimal calibrations are critical. This paper describes the TOF detector, its calibration procedure, the achieved resolution, the long term operation performances and some of the first results from data analysis using this detector.

  5. Time of flight system on a chip

    NASA Technical Reports Server (NTRS)

    Paschalidis, Nicholas P. (Inventor)

    2006-01-01

    A CMOS time-of-flight TOF system-on-a-chip SoC for precise time interval measurement with low power consumption and high counting rate has been developed. The analog and digital TOF chip may include two Constant Fraction Discriminators CFDs and a Time-to-Digital Converter TDC. The CFDs can interface to start and stop anodes through two preamplifiers and perform signal processing for time walk compensation (110). The TDC digitizes the time difference with reference to an off-chip precise external clock (114). One TOF output is an 11-bit digital word and a valid event trigger output indicating a valid event on the 11-bit output bus (116).

  6. Time-of-Flight Microwave Camera.

    PubMed

    Charvat, Gregory; Temme, Andrew; Feigin, Micha; Raskar, Ramesh

    2015-10-05

    Microwaves can penetrate many obstructions that are opaque at visible wavelengths, however microwave imaging is challenging due to resolution limits associated with relatively small apertures and unrecoverable "stealth" regions due to the specularity of most objects at microwave frequencies. We demonstrate a multispectral time-of-flight microwave imaging system which overcomes these challenges with a large passive aperture to improve lateral resolution, multiple illumination points with a data fusion method to reduce stealth regions, and a frequency modulated continuous wave (FMCW) receiver to achieve depth resolution. The camera captures images with a resolution of 1.5 degrees, multispectral images across the X frequency band (8 GHz-12 GHz), and a time resolution of 200 ps (6 cm optical path in free space). Images are taken of objects in free space as well as behind drywall and plywood. This architecture allows "camera-like" behavior from a microwave imaging system and is practical for imaging everyday objects in the microwave spectrum.

  7. Miniature Time-of-Flight Mass Spectrometer

    NASA Technical Reports Server (NTRS)

    Potember, Richard S.

    1999-01-01

    Major advances must occur to protect astronauts from prolonged periods in near-zero gravity and high radiation associated with extended space travel. The dangers of living in space must be thoroughly understood and methods developed to reverse those effects that cannot be avoided. Six of the seven research teams established by the National Space Biomedical Research Institute (NSBRI) are studying biomedical factors for prolonged space travel to deliver effective countermeasures. To develop effective countermeasures, each of these teams require identification of and quantitation of complex pharmacological, hormonal, and growth factor compounds (biomarkers) in humans and in experimental animals to develop an in-depth knowledge of the physiological changes associated with space travel. At present, identification of each biomarker requires a separate protocol. Many of these procedures are complicated and the identification of each biomarker requires a separate protocol and associated laboratory equipment. To carry all of this equipment and chemicals on a spacecraft would require a complex clinical laboratory; and it would occupy much of the astronauts time. What is needed is a small, efficient, broadband medical diagnostic instrument to rapidly identify important biomarkers for human space exploration. The Miniature Time-Of- Flight Mass Spectrometer Project in the Technology Development Team is developing a small, high resolution, time-of-flight mass spectrometer (TOFMS) to quantitatively measure biomarkers for human space exploration. Virtues of the JHU/APL TOFMS technologies reside in the promise for a small (less than one cubic ft), lightweight (less than 5 kg), low-power (less than 50 watts), rugged device that can be used continuously with advanced signal processing diagnostics. To date, the JHU/APL program has demonstrated mass capability from under 100 to beyond 10,000 atomic mass units (amu) in a very small, low power prototype for biological analysis. Further

  8. Miniaturised Time-of-Flight Mass Spectrometer

    NASA Astrophysics Data System (ADS)

    Rohner, U.; Benz, W.; Whitby, J. A.; Wurz, P.; Schulz, R.; Romstedt, J.

    2004-04-01

    Originally intended for the European Space Agency's BepiColombo mission to Mercury, we have built a series of highly miniaturised laser ablation time of flight mass spectrometers (LMS), suitable for in situ measurements of the elemental and isotopic composition of the surface of airless planetary bodies. The instruments will determine ma jor, minor, and trace element abundances in minerals on a spatial scale of 10 m, and will have sufficient dynamic range and mass resolution to perform useful isotopic measurements in favourable cases. Solid material is simultaneously evaporated and ionised by means of laser ablation, requiring intense pulsed laser radiation. Laser ablation was chosen as the sample introduction technique principally because of its high spatial resolution and the lack of any need for sample preparation. Advantages of the technique include simplicity of the resulting design, speed of measurement, and the ability for depth profiling (potentially important for a regolith in which mineral grains are coated with impact produced glass). Time of flight mass spectrometers are simple, robust devices that couple well to a pulsed ion source and we have previous experience of their construction for space flight, e.g. the ROSINA instrument suite for the ROSETTA mission. For BepiColombo, we have built two prototype instruments, one with a design mass of 500 g and a volume comparable to a beer can intended to be deployed on a static lander, and a smaller cigarettebox sized version with a design mass of 250 g, small enough to be integrated in a rover or robotic arm.

  9. Advances in time-of-flight PET

    PubMed Central

    Surti, Suleman; Karp, Joel S.

    2016-01-01

    This paper provides a review and an update on time-of-flight PET imaging with a focus on PET instrumentation, ranging from hardware design to software algorithms. We first present a short introduction to PET, followed by a description of TOF PET imaging and its history from the early days. Next, we introduce the current state-of-art in TOF PET technology and briefly summarize the benefits of TOF PET imaging. This is followed by a discussion of the various technological advancements in hardware (scintillators, photo-sensors, electronics) and software (image reconstruction) that have led to the current widespread use of TOF PET technology, and future developments that have the potential for further improvements in the TOF imaging performance. We conclude with a discussion of some new research areas that have opened up in PET imaging as a result of having good system timing resolution, ranging from new algorithms for attenuation correction, through efficient system calibration techniques, to potential for new PET system designs. PMID:26778577

  10. Time-of-Flight Microwave Camera

    PubMed Central

    Charvat, Gregory; Temme, Andrew; Feigin, Micha; Raskar, Ramesh

    2015-01-01

    Microwaves can penetrate many obstructions that are opaque at visible wavelengths, however microwave imaging is challenging due to resolution limits associated with relatively small apertures and unrecoverable “stealth” regions due to the specularity of most objects at microwave frequencies. We demonstrate a multispectral time-of-flight microwave imaging system which overcomes these challenges with a large passive aperture to improve lateral resolution, multiple illumination points with a data fusion method to reduce stealth regions, and a frequency modulated continuous wave (FMCW) receiver to achieve depth resolution. The camera captures images with a resolution of 1.5 degrees, multispectral images across the X frequency band (8 GHz–12 GHz), and a time resolution of 200 ps (6 cm optical path in free space). Images are taken of objects in free space as well as behind drywall and plywood. This architecture allows “camera-like” behavior from a microwave imaging system and is practical for imaging everyday objects in the microwave spectrum. PMID:26434598

  11. Time-of-Flight Microwave Camera

    NASA Astrophysics Data System (ADS)

    Charvat, Gregory; Temme, Andrew; Feigin, Micha; Raskar, Ramesh

    2015-10-01

    Microwaves can penetrate many obstructions that are opaque at visible wavelengths, however microwave imaging is challenging due to resolution limits associated with relatively small apertures and unrecoverable “stealth” regions due to the specularity of most objects at microwave frequencies. We demonstrate a multispectral time-of-flight microwave imaging system which overcomes these challenges with a large passive aperture to improve lateral resolution, multiple illumination points with a data fusion method to reduce stealth regions, and a frequency modulated continuous wave (FMCW) receiver to achieve depth resolution. The camera captures images with a resolution of 1.5 degrees, multispectral images across the X frequency band (8 GHz-12 GHz), and a time resolution of 200 ps (6 cm optical path in free space). Images are taken of objects in free space as well as behind drywall and plywood. This architecture allows “camera-like” behavior from a microwave imaging system and is practical for imaging everyday objects in the microwave spectrum.

  12. Analytical properties of time-of-flight PET data.

    PubMed

    Cho, Sanghee; Ahn, Sangtae; Li, Quanzheng; Leahy, Richard M

    2008-06-07

    We investigate the analytical properties of time-of-flight (TOF) positron emission tomography (PET) sinograms, where the data are modeled as line integrals weighted by a spatially invariant TOF kernel. First, we investigate the Fourier transform properties of 2D TOF data and extend the 'bow-tie' property of the 2D Radon transform to the time-of-flight case. Second, we describe a new exact Fourier rebinning method, TOF-FOREX, based on the Fourier transform in the time-of-flight variable. We then combine TOF-FOREX rebinning with a direct extension of the projection slice theorem to TOF data, to perform fast 3D TOF PET image reconstruction. Finally, we illustrate these properties using simulated data.

  13. Analytical Properties of Time-of-Flight PET Data

    PubMed Central

    Cho, Sanghee; Ahn, Sangtae; Li, Quanzheng; Leahy, Richard M.

    2015-01-01

    We investigate the analytical properties of time-of-flight (TOF) positron emission tomography (PET) sinograms, where the data are modeled as line integrals weighted by a spatially invariant TOF kernel. First, we investigate the Fourier transform properties of 2D TOF data and extend the “bow-tie” property of the 2D Radon transform to the time of flight case. Second, we describe a new exact Fourier rebinning method, TOF-FOREX, based on the Fourier transform in the time-of-flight variable. We then combine TOF-FOREX rebinning with a direct extension of the projection slice theorem to TOF data, to perform fast 3D TOF PET image reconstruction. Finally, we illustrate these properties using simulated data. PMID:18460746

  14. Analytical properties of time-of-flight PET data

    NASA Astrophysics Data System (ADS)

    Cho, Sanghee; Ahn, Sangtae; Li, Quanzheng; Leahy, Richard M.

    2008-06-01

    We investigate the analytical properties of time-of-flight (TOF) positron emission tomography (PET) sinograms, where the data are modeled as line integrals weighted by a spatially invariant TOF kernel. First, we investigate the Fourier transform properties of 2D TOF data and extend the 'bow-tie' property of the 2D Radon transform to the time-of-flight case. Second, we describe a new exact Fourier rebinning method, TOF-FOREX, based on the Fourier transform in the time-of-flight variable. We then combine TOF-FOREX rebinning with a direct extension of the projection slice theorem to TOF data, to perform fast 3D TOF PET image reconstruction. Finally, we illustrate these properties using simulated data.

  15. Recipes for high resolution time-of-flight detectors

    SciTech Connect

    Anz, S.J. |; Felter, T.E.; Hess, B.V.; Daley, R.S.; Roberts, M.L.; Williams, R.S.

    1995-01-01

    The authors discuss the dynamics, construction, implementation and benefits of a time-of-flight (TOF) detector with count rates an order of magnitude higher and resolution three to four times better than that obtainable with a surface barrier detector. The propose use of design criteria for a time-of-flight detector is outlined, and the determination of a TOF detector`s total relative timing error and how this value determines the mass resolution are illustrated using a graphical analysis. They present simulation and experimental examples employing light ions and discuss advantages and pitfalls of medium-energy heavy ion TOF spectrometry.

  16. Time-of-Flight Mass Measurements of Neutron Rich Nuclides

    NASA Astrophysics Data System (ADS)

    Estrade, A.; Matos, M.; Amthor, A. M.; Becerril, A.; Elliot, T.; Lorusso, G.; Rogers, A.; Schatz, H.; Bazin, D.; Gade, A.; Portillo, M.; Stolz, A.; Galaviz, D.; Pereira, J.; Shapira, D.; Smith, E.; Wallace, M.

    2008-10-01

    Nuclear masses of neutron rich isotopes in the region of Z ˜ 20-30 have been measured using the time-of-flight technique at the National Superconducting Cyclotron Laboratory (NSCL). The masses of 5 isotopes have been measured for the first time, and the precision of several other masses has been improved. The time-of-flight technique has shown the potential to access nuclear masses very far from stability when applied at radioactive beam facilities like the NSCL. Such measurements are important for understanding nuclear structure far from the valley of β-stability, and provide valuable information for astrophysical model calculations of processes involving very unstable nuclides.

  17. Electronics for a Picosecond Time-of-flight Measurement

    SciTech Connect

    Brandt, Andrew Gerhart; Rijssenbeek, Michael

    2014-11-03

    TITLE: Electronics for a Picosecond Time-of-flight Measurement ABSTRACT: Time-of-flight (TOF) detectors have historically been used as part of the particle identification capability of multi-purpose particle physics detectors. An accurate time measurement, combined with a momentum measurement based on the curvature of the track in a magnetic field, is often sufficient to determine the particle's mass, and thus its identity. Such detectors typically have measured the particle flight time extremely precisely, with an uncertainty of one hundred trillionths of a second (also referred to as 100 picoseconds). To put this in perspective it would be like counting all the people on the Earth and getting it right within 1 person! Another use of TOFs is to measure the vertex of the event, which is the location along the beam line where the incoming particles (typically protons) collide. This vertex positon is a well measured quantity for events where the protons collide “head on” as the outgoing particles produced when you blast the proton apart can be used to trace back to a vertex point from which they originated. More frequently the protons just strike a glancing blow and remain intact—in this case they are nearly parallel to the beam and you cannot tell their vertex without this ability to precisely measure the time of flight of the protons. Occasionally both happen in the same event, that is, a central system and two protons are produced. But are they from the same collision, or just a boring background where more than one collision in the same bunch crossing conspire to fake the signal of interest? That’s where the timing of the protons comes into play. The main idea is to measure the time it takes for the two protons to reach TOF detectors positioned equidistant from the center of the main detector. If the vertex is displaced to one side than that detector will measure a shorter time while the other side detector will measure a correspondingly longer time

  18. The sTOF, a Favorable Geometry for a Time-of-Flight Analyzer

    NASA Astrophysics Data System (ADS)

    Murphy, Daniel M.

    2017-02-01

    A new geometry for the flight region in a time-of-flight mass spectrometer is presented. It consists of two opposing electrostatic sectors of about 255° each and straight sections with a length appropriate to the turns. The resulting geometry folds into a compact space. The first-order aberrations for position, angle, and energy are all zero. The transverse focusing properties are also excellent. For an energetic, high-divergence ion source such as laser ablation, the sTOF has higher resolution and ion transmission than a reflectron of similar physical size.

  19. Highly segmented, high resolution time-of-flight system

    SciTech Connect

    Nayak, T.K.; Nagamiya, S.; Vossnack, O.; Wu, Y.D.; Zajc, W.A.; Miake, Y.; Ueno, S.; Kitayama, H.; Nagasaka, Y.; Tomizawa, K.; Arai, I.; Yagi, K

    1991-12-31

    The light attenuation and timing characteristics of time-of-flight counters constructed of 3m long scintillating fiber bundles of different shapes and sizes are presented. Fiber bundles made of 5mm diameter fibers showed good timing characteristics and less light attenuation. The results for a 1.5m long scintillator rod are also presented.

  20. Proposal for Cherenkov Time of Flight Technique with Picosecond Resolution

    SciTech Connect

    S. Majewski; A. Margaryan; L. Tang

    2005-08-05

    A new particle identification device for Jlab 12 GeV program is proposed. It is based on the measurement of time information obtained by means of a new photon detector and time measuring concept. The expected time measurement precision for the Cherenkov time-of-flight detector is about or less than 10 picosecond for Cherenkov radiators with lengths less than 50 cm.

  1. Rocket-borne time-of-flight mass spectrometry

    NASA Technical Reports Server (NTRS)

    Reiter, R. F.

    1976-01-01

    Theoretical and numerical analyses are made of planar, cylindrical and spherical-electrode two-field time-of-flight mass spectrometers in order to optimize their operating conditions. A method is introduced which can improve the resolving power of these instruments by a factor of 7.5. Potential barrier gating in time-of-flight mass spectrometers is also analyzed. Experimental studies of a miniature cylindrical-electrode and a hemispherical-electrode time-of-flight mass spectrometer are presented. Their sensitivity and ability to operate at D-region pressures with an open source make them ideal instruments for D-region ion composition measurements. A sounding rocket experiment package carrying a cylindrical electrode time-of-flight mass spectrometer was launched. The data indicate that essentially 100% of the positive electric charge on positive ions is carried by ions with mass-to-charge ratios greater than 500 below an altitude of 92 km. These heavy charge carriers were present at altitudes up to about 100 km.

  2. 14 CFR 398.7 - Timing of flights.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Timing of flights. 398.7 Section 398.7 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) POLICY... reasonableness of the time in view of the purpose for which the local passengers are traveling. If travel...

  3. KELVIN rare gas time-of-flight program

    SciTech Connect

    Vernon, M.

    1981-03-01

    The purpose of this appendix is to explain in detail the procedure for performing time-of-flight (TOF) calibration measurements. The result of the calibration measurements is to assign a correct length (L) to the path the molecules travel in a particular experimental configuration. In conjunction with time information (t) a velocity distribution (L/t) can then be determined. The program KELVIN is listed.

  4. Time-of-flight direct recoil ion scattering spectrometer

    DOEpatents

    Krauss, Alan R.; Gruen, Dieter M.; Lamich, George J.

    1994-01-01

    A time of flight direct recoil and ion scattering spectrometer beam line (10). The beam line (10) includes an ion source (12) which injects ions into pulse deflection regions (14) and (16) separated by a drift space (18). A final optics stage includes an ion lens and deflection plate assembly (22). The ion pulse length and pulse interval are determined by computerized adjustment of the timing between the voltage pulses applied to the pulsed deflection regions (14) and (16).

  5. Development of a 10 picosecond time-of-flight Counter

    SciTech Connect

    Brandt, Andrew G

    2010-03-18

    This Advanced Detector Research proposal presented a plan to develop an extremely fast time-of-flight detector for measuring the arrival time of beam protons scattered at small angles in high energy hadron colliders, such as the Large Hadron Collider (LHC). The proposed detectors employ a gas or quartz Cerenkov radiator which produce light when a proton passes through them, coupled to a micro-channel plate photomultiplier tube (MCP-PMT) that converts the light to an electrical pulse. The very small jitter of the pulse time provided by the MCP-PMT, combined with downstream electronics that accurately measure the pulse time results in a time-of-flight measurement of unprecedented accuracy. This ADR proposal was extremely successful, culminating in the development of a 10 ps resolution time-of-flight system, about an order of magnitude better than any time-of-flight system previously deployed at a collider experiment. The primary areas of advance were the usage of new radiator geometries providing fast detector signals, using multiple measurements to obtain a superior system resolution, and development of an electronics readout system tuned to maintain the excellent timing afforded by the detector. Test beam and laser tests have improved the knowledge of MCP-PMT’s and enabled the evaluation of the new detector concepts. In addition to being a generally useful detector concept, these fast timing detectors are a major component of proposed upgrades to the LHC ATLAS and CMS detectors, and if deployed could significantly enhance the discovery potential of these detectors, including contributions to the measurement of the properties of the Higgs Boson. In addition to the potential for furthering fundamental understanding of nature, the knowledge gained on MCP-PMT’s could be useful in developing improved versions of these devices which have promise in diverse fields such as biological and medical imaging.

  6. Time-of-flight direct recoil ion scattering spectrometer

    DOEpatents

    Krauss, A.R.; Gruen, D.M.; Lamich, G.J.

    1994-09-13

    A time-of-flight direct recoil and ion scattering spectrometer beam line is disclosed. The beam line includes an ion source which injects ions into pulse deflection regions and separated by a drift space. A final optics stage includes an ion lens and deflection plate assembly. The ion pulse length and pulse interval are determined by computerized adjustment of the timing between the voltage pulses applied to the pulsed deflection regions. 23 figs.

  7. Continuous time-of-flight ion mass spectrometer

    DOEpatents

    Funsten, Herbert O.; Feldman, William C.

    2004-10-19

    A continuous time-of-flight mass spectrometer having an evacuated enclosure with means for generating an electric field located in the evacuated enclosure and means for injecting a sample material into the electric field. A source of continuous ionizing radiation injects ionizing radiation into the electric field to ionize atoms or molecules of the sample material, and timing means determine the time elapsed between arrival of a secondary electron out of said ionized atoms or molecules at a first predetermined location and arrival of a sample ion out of said ionized atoms or molecules at a second predetermined location.

  8. Compensated time of flight telescope for spaceborne cosmic ray measurements

    NASA Technical Reports Server (NTRS)

    Rothermel, H.

    1977-01-01

    A large area time-of-flight telescope has been studied for future application in space-borne cosmic ray experiments. A new compensation technique for propagation delays inside the scintillators has been applied, which is operative in two perpendicular directions. This technique, superior to conventional one-dimensional compensations, allows high rejection probability for upward moving single particles at very short counter distances. Besides mechanical advantages a short counter distance is desirable because it permits a large field of view for the detector. A measurement of light transit times in scintillators is presented and based on it, directionality for shower events is discussed.

  9. Time-of-Flight Tip-Clearance Measurements

    NASA Technical Reports Server (NTRS)

    Dhadwal, H. S.; Kurkov, A. P.; Janetzke, D. C.

    1999-01-01

    In this paper a time-of-flight probe system incorporating the two integrated fiber optic probes which are tilted equally relative to the probe holder centerline, is applied for the first time to measure the tip clearance of an advanced fan prototype. Tip clearance is largely independent of the signal amplitude and it relies on timing measurement. This work exposes optical effects associated with the fan blade stagger angle that were absent during the original spin-rig experiment on the zero stagger rotor. Individual blade tip clearances were measured with accuracy of +/- 127-mm (+/- 0.005-in). Probe features are discussed and improvements to the design are suggested.

  10. An introduction to quadrupole-time-of-flight mass spectrometry.

    PubMed

    Chernushevich, I V; Loboda, A V; Thomson, B A

    2001-08-01

    A brief introduction is presented to the basic principles and application of a quadrupole-time-of-flight (TOF) tandem mass spectrometer. The main features of reflecting TOF instruments with orthogonal injection of ions are discussed. Their operation and performance are compared with those of triple quadrupoles with electrospray ionization and matrix-assisted laser desorption/ionization (MALDI) TOF mass spectrometers. Examples and recommendations are provided for all major operational modes: mass spectrometry (MS) and tandem MS (MS/MS), precursor ion scans and studies of non-covalent complexes. Basic algorithms for liquid chromatography/MS/MS automation are discussed and illustrated by two applications.

  11. Miniature Focusing Time-of-Flight Mass Spectrometer

    NASA Technical Reports Server (NTRS)

    Kanik, Isik; Srivastava, Santosh

    2005-01-01

    An improved miniature time-of-flight mass spectrometer has been developed in a continuing effort to minimize the sizes, weights, power demands, and costs of mass spectrometers for such diverse applications as measurement of concentrations of pollutants in the atmosphere, detecting poisonous gases in mines, and analyzing exhaust gases of automobiles. Advantageous characteristics of this mass spectrometer include the following: It is simple and rugged. Relative to prior mass spectrometers, it is inexpensive to build. There is no need for precise alignment of its components. Its mass range is practically unlimited Relative to prior mass spectrometers, it offers high sensitivity (ability to measure relative concentrations as small as parts per billion). Its resolution is one dalton (one atomic mass unit). An entire mass spectrum is recorded in a single pulse. (In a conventional mass spectrometer, a spectrum is recorded mass by mass.) The data-acquisition process takes only seconds. It is a lightweight, low-power, portable instrument. Although time-of-flight mass spectrometers (TOF-MSs) have been miniaturized previously, their performances have not been completely satisfactory. An inherent adverse effect of miniaturization of a TOF-MS is a loss of resolution caused by reduction of the length of its flight tube. In the present improved TOF-MS, the adverse effect of shortening the flight tube is counteracted by (1) using charged-particle optics to constrain ion trajectories to the flight-tube axis while (2) reducing ion velocities to increase ion flight times. In the present improved TOF-MS, a stream of gas is generated by use of a hypodermic needle. The stream of gas is crossed by an energy-selected, pulsed beam of electrons (see Figure 1). The ions generated by impingement of the electrons on the gas atoms are then focused by three cylindrical electrostatic lenses, which constitute a segmented flight tube. After traveling along the flight tube, the ions enter a charged

  12. Fast neutron measurements at the nELBE time-of-flight facility

    NASA Astrophysics Data System (ADS)

    Junghansa, A. R.; Beyer, R.; Grosse, E.; Hannaske, R.; Kögler, T.; Massarczyk, R.; Schwengner, R.; Wagner, A.

    2015-05-01

    The compact neutron-time-of-flight facility nELBE at the superconducting electron accelerator ELBE of Helmholtz-Zentrum Dresden-Rossendorf has been rebuilt. A new enlarged experimental hall with a flight path of up to 10 m is available for neutron time-of-flight experiments in the fast energy range from about 50 keV to 10 MeV. nELBE is intended to deliver nuclear data of fast neutron nuclear interactions e.g. for the transmutation of nuclear waste and improvement of neutron physical simulations of innovative nuclear systems. The experimental programme consists of transmission measurements of neutron total cross sections, elastic and inelastic scattering cross section measurements, and neutron induced fission cross sections. The inelastic scattering to the first few excited states in 56Fe was investigated by measuring the gamma production cross section with an HPGe detector. The neutron induced fission of 242Pu was studied using fast ionisation chambers with large homogeneous actinide deposits.

  13. Time of flight Laue fiber diffraction studies of perdeuterated DNA

    SciTech Connect

    Forsyth, V.T.; Whalley, M.A.; Mahendrasingam, A.; Fuller, W.

    1994-12-31

    The diffractometer SXD at the Rutherford Appleton Laboratory ISIS pulsed neutron source has been used to record high resolution time-of-flight Laue fiber diffraction data from DNA. These experiments, which are the first of their kind, were undertaken using fibers of DNA in the A conformation and prepared using deuterated DNA in order to minimis incoherent background scattering. These studies complement previous experiments on instrument D19 at the Institute Laue Langevin using monochromatic neutrons. Sample preparation involved drawing large numbers of these deuterated DNA fibers and mounting them in a parallel array. The strategy of data collection is discussed in terms of camera design, sample environment and data collection. The methods used to correct the recorded time-of-flight data and map it into the final reciprocal space fiber diffraction dataset are also discussed. Difference Fourier maps showing the distribution of water around A-DNA calculated on the basis of these data are compared with results obtained using data recorded from hydrogenated A-DNA on D19. Since the methods used for sample preparation, data collection and data processing are fundamentally different for the monochromatic and Laue techniques, the results of these experiments also afford a valuable opportunity to independently test the data reduction and analysis techniques used in the two methods.

  14. Time-of-flight mass spectrometry: Introduction to the basics.

    PubMed

    Boesl, Ulrich

    2017-01-01

    The intention of this tutorial is to introduce into the basic concepts of time-of-flight mass spectrometry, beginning with the most simple single-stage ion source with linear field-free drift region and continuing with two-stage ion sources combined with field-free drift regions and ion reflectors-the so-called reflectrons. Basic formulas are presented and discussed with the focus on understanding the physical relations of geometric and electric parameters, initial distribution of ionic parameters, ion flight times, and ion flight time incertitude. This tutorial is aimed to help the applicant to identify sources of flight time broadening which limit good mass resolution and sources of ion losses which limit sensitivity; it is aimed to stimulate creativity for new experimental approaches by discussing a choice of instrumental options and to encourage those who toy with the idea to build an own time-of-flight mass spectrometer. Large parts of mathematics are shifted into a separate chapter in order not to overburden the text with too many mathematical deviations. Rather, thumb-rule formulas are supplied for first estimations of geometry and potentials when designing a home-built instrument, planning experiments, or searching for sources of flight time broadening. © 2016 Wiley Periodicals, Inc. Mass Spec Rev 36:86-109, 2017.

  15. Inductively Coupled Plasma Zoom-Time-of-Flight Mass Spectrometry.

    PubMed

    Dennis, Elise A; Ray, Steven J; Enke, Christie G; Hieftje, Gary M

    2016-03-01

    A zoom-time-of-flight mass spectrometer has been coupled to an inductively coupled plasma (ICP) ionization source. Zoom-time-of-flight mass spectrometry (zoom-TOFMS) combines two complementary types of velocity-based mass separation. Specifically, zoom-TOFMS alternates between conventional, constant-energy acceleration (CEA) TOFMS and energy-focused, constant-momentum acceleration (CMA) (zoom) TOFMS. The CMA mode provides a mass-resolution enhancement of 1.5-1.7× over CEA-TOFMS in the current, 35-cm ICP-zoom-TOFMS instrument geometry. The maximum resolving power (full-width at half-maximum) for the ICP-zoom-TOFMS instrument is 1200 for CEA-TOFMS and 1900 for CMA-TOFMS. The CMA mode yields detection limits of between 0.02 and 0.8 ppt, depending upon the repetition rate and integration time-compared with single ppt detection limits for CEA-TOFMS. Isotope-ratio precision is shot-noise limited at approximately 0.2% relative-standard deviation (RSD) for both CEA- and CMA-TOFMS at a 10 kHz repetition rate and an integration time of 3-5 min. When the repetition rate is increased to 43.5 kHz for CMA, the shot-noise limited, zoom-mode isotope-ratio precision is improved to 0.09% RSD for the same integration time.

  16. TITAN's multiple-reflection time-of-flight isobar separator

    NASA Astrophysics Data System (ADS)

    Reiter, Moritz Pascal; Titan Collaboration

    2016-09-01

    At the ISAC facility located at TRIUMF exotic nuclei are produced by the ISOL method. Exotic nuclei are separated by a magnetic separator and transported to TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). TITAN is a system of multiple ion traps for high precision mass measurements and in-trap decay spectroscopy. Although ISAC can deliver some of the highest yields for even many of the most exotic species many measurements suffer from a strong isobaric background. This background often prevents the high precision measurement of the species of interest. To overcome this limitation an additional isobar separator based on the Multiple-Reflection Time-Of-Flight Mass Spectrometry (MR-TOF-MS) technique has been developed for TITAN. Mass selection is achieved using dynamic re-trapping of the species of interest after a time-of-flight analysis in an electrostatic isochronous reflector system. Additionally the MR-TOF-MS will, on its own, enable mass measurements of very short-lived nuclides that are weakly produced. Being able to measure all isobars of a given mass number at the same time the MR-TOF-MS can be used for beam diagnostics or determination of beam compositions. Results from the offline commissioning showing mass resolving power and separation power will be presented.

  17. Development of EndoTOFPET-US, a multi-modal endoscope for ultrasound and time of flight positron emission tomography

    NASA Astrophysics Data System (ADS)

    Pizzichemi, M.

    2014-02-01

    The EndoTOFPET-US project aims at delevoping a multi-modal imaging device that combines Ultrasound with Time-Of-Flight Positron Emission Tomography into an endoscopic imaging device. The goal is to obtain a coincidence time resolution of about 200 ps FWHM and sub-millimetric spatial resolution for the PET head, integrating the components in a very compact detector suitable for endoscopic use. The scanner will be exploited for the clinical test of new bio-markers especially targeted for prostate and pancreatic cancer as well as for diagnostic and surgical oncology. This paper focuses on the status of the Time-Of-Flight Positron Emission Tomograph under development for the EndoTOFPET-US project.

  18. Time-of-flight detector for heavy ion backscattering spectrometry

    SciTech Connect

    Knapp, J.A.; Banks, J.C.; Doyle, B.L.

    1994-04-01

    This report describes the results of a two-year laboratory directed research and development project to explore advanced concepts in Heavy Ion Backscattering Spectrometry (HIBS), undertaken with the goal of extending the sensitivity of this relatively new technique to levels unattainable by any other existing trace element surface analysis. Improvements in sensitivity are required for the application of HIBS to contamination control in the microelectronics industry. Tools with sensitivity approaching 10{sup 8} atoms/cm{sup 2} are expected to be essential for enabling advanced IC production by the year 2000. During the project the authors developed a new analysis chamber with channeling goniometer and a prototype time-of-flight detector with a demonstrated sensitivity of {approximately} 5 {times} 10{sup 8} atoms/cm{sup 2} for Au on Si and {approximately} 5 {times} 10{sup 10} for Fe, and sufficient mass resolution to separate contributions from Fe and Cu.

  19. Avalanche photodiode based time-of-flight mass spectrometry

    SciTech Connect

    Ogasawara, Keiichi Livi, Stefano A.; Desai, Mihir I.; Ebert, Robert W.; McComas, David J.; Walther, Brandon C.

    2015-08-15

    This study reports on the performance of Avalanche Photodiodes (APDs) as a timing detector for ion Time-of-Flight (TOF) mass spectroscopy. We found that the fast signal carrier speed in a reach-through type APD enables an extremely short timescale response with a mass or energy independent <2 ns rise time for <200 keV ions (1−40 AMU) under proper bias voltage operations. When combined with a microchannel plate to detect start electron signals from an ultra-thin carbon foil, the APD comprises a novel TOF system that successfully operates with a <0.8 ns intrinsic timing resolution even using commercial off-the-shelf constant-fraction discriminators. By replacing conventional total-energy detectors in the TOF-Energy system, APDs offer significant power and mass savings or an anti-coincidence background rejection capability in future space instrumentation.

  20. Accurate Fiber Length Measurement Using Time-of-Flight Technique

    NASA Astrophysics Data System (ADS)

    Terra, Osama; Hussein, Hatem

    2016-06-01

    Fiber artifacts of very well-measured length are required for the calibration of optical time domain reflectometers (OTDR). In this paper accurate length measurement of different fiber lengths using the time-of-flight technique is performed. A setup is proposed to measure accurately lengths from 1 to 40 km at 1,550 and 1,310 nm using high-speed electro-optic modulator and photodetector. This setup offers traceability to the SI unit of time, the second (and hence to meter by definition), by locking the time interval counter to the Global Positioning System (GPS)-disciplined quartz oscillator. Additionally, the length of a recirculating loop artifact is measured and compared with the measurement made for the same fiber by the National Physical Laboratory of United Kingdom (NPL). Finally, a method is proposed to relatively correct the fiber refractive index to allow accurate fiber length measurement.

  1. The Time-of-Flight trigger at CDF

    SciTech Connect

    Bauer, G.; Mulhearn, M.J.; Paus, Ch.; Schieferdecker, P.; Tether, S.; Lewis, J.D.; Shaw, T.; Acosta, D.; Konigsberg, J.; Madorsky, A.; /Florida U.

    2006-05-01

    The Time-of-Flight (TOF) detector measures the arrival time and deposited energy of charged particles reaching scintillator bars surrounding the central tracking region of the CDF detector. Requiring high ionization in the TOF system provides a unique trigger capability, which has been used for a magnetic monopole search. Other uses, with smaller pulse height thresholds, include a high-multiplicity charged-particle trigger useful for QCD studies and a much improved cosmic ray trigger for calibrating other detector components. Although not designed as input to CDF's global Level 1 trigger, the TOF system has been easily adapted to this role by the addition of 24 cables, new firmware, and four custom TOF trigger boards (TOTRIBs). This article describes the TOF trigger.

  2. Tests and calibration of NIF neutron time of flight detectors.

    PubMed

    Ali, Z A; Glebov, V Yu; Cruz, M; Duffy, T; Stoeckl, C; Roberts, S; Sangster, T C; Tommasini, R; Throop, A; Moran, M; Dauffy, L; Horsefield, C

    2008-10-01

    The National Ignition Facility (NIF) neutron time of flight (NTOF) diagnostic will measure neutron yield and ion temperature in all NIF campaigns in DD, DT, and THD(*) implosions. The NIF NTOF diagnostic is designed to measure neutron yield from 1x10(9) to 2x10(19). The NTOF consists of several detectors of varying sensitivity located on the NIF at about 5 and 20 m from the target. Production, testing, and calibration of the NIF NTOF detectors have begun at the Laboratory for Laser Energetics (LLE). Operational tests of the NTOF detectors were performed on several facilities including the OMEGA laser at LLE and the Titan laser at Lawrence Livermore National Laboratory. Neutron calibrations were carried out on the OMEGA laser. Results of the NTOF detector tests and calibration will be presented.

  3. The time-of-flight wall for the HADES spectrometer

    SciTech Connect

    Agodi, C.; Bassi, A.; Bassini, R.

    1998-06-01

    In the framework of the HADES (High Acceptance DiElectron Spectrometer) collaboration the authors are developing the Time Of Flight (TOF) wall subdetector. In order to efficiently select events with e{sup +}e{sup {minus}} pairs produced in the nuclear matter, the TOF wall must be able to resolve electrons from pions up to 0.5 GeV/c and from protons up to 2 GeV/c. Because the short flight path of about 2m requires a 100--150 ps time resolution, the authors are building a granular system made of scintillator rods readout on both ends by means of photomultipliers, capable of such performance.

  4. Linear electronic field time-of-flight ion mass spectrometers

    DOEpatents

    Funsten, Herbert O.

    2010-08-24

    Time-of-flight mass spectrometer comprising a first drift region and a second drift region enclosed within an evacuation chamber; a means of introducing an analyte of interest into the first drift region; a pulsed ionization source which produces molecular ions from said analyte of interest; a first foil positioned between the first drift region and the second drift region, which dissociates said molecular ions into constituent atomic ions and emits secondary electrons; an electrode which produces secondary electrons upon contact with a constituent atomic ion in second drift region; a stop detector comprising a first ion detection region and a second ion detection region; and a timing means connected to the pulsed ionization source, to the first ion detection region, and to the second ion detection region.

  5. Highly charged ion based time of flight emission microscope

    DOEpatents

    Barnes, Alan V.; Schenkel, Thomas; Hamza, Alex V.; Schneider, Dieter H.; Doyle, Barney

    2001-01-01

    A highly charged ion based time-of-flight emission microscope has been designed, which improves the surface sensitivity of static SIMS measurements because of the higher ionization probability of highly charged ions. Slow, highly charged ions are produced in an electron beam ion trap and are directed to the sample surface. The sputtered secondary ions and electrons pass through a specially designed objective lens to a microchannel plate detector. This new instrument permits high surface sensitivity (10.sup.10 atoms/cm.sup.2), high spatial resolution (100 nm), and chemical structural information due to the high molecular ion yields. The high secondary ion yield permits coincidence counting, which can be used to enhance determination of chemical and topological structure and to correlate specific molecular species.

  6. Chern numbers hiding in time-of-flight images

    SciTech Connect

    Zhao Erhai; Satija, Indubala I.; Bray-Ali, Noah; Williams, Carl J.; Spielman, I. B.

    2011-12-15

    We present a technique for detecting topological invariants--Chern numbers--from time-of-flight images of ultracold atoms. We show that the Chern numbers of integer quantum Hall states of lattice fermions leave their fingerprints in the atoms' momentum distribution. We analytically demonstrate that the number of local maxima in the momentum distribution is equal to the Chern number in two limiting cases, for large hopping anisotropy and in the continuum limit. In addition, our numerical simulations beyond these two limits show that these local maxima persist for a range of parameters. Thus, an everyday observable in cold atom experiments can serve as a useful tool to characterize and visualize quantum states with nontrivial topology.

  7. Time-of-flight Fourier Spectrometry with UCN

    NASA Astrophysics Data System (ADS)

    Kulin, G. V.; Frank, A. I.; Goryunov, S. V.; Geltenbort, P.; Jentschel, M.; Bushuev, V. A.; Lauss, B.; Schmidt-Wellenburg, Ph.; Panzarella, A.; Fuchs, Y.

    2016-09-01

    The report presents the first experience of using a time-of-flight Fourier spectrometer of ultracold neutrons (UCN). The description of the spectrometer design and first results of its testing are presented. The results of the first experiments show that the spectrometer may be used for obtaining UCN energy spectra in the energy range of 60÷200 neV with a resolution of about 5 neV. The application of TOF Fourier spectrometry technique allowed us to obtain the energy spectra from the diffraction of monochromatic ultracold neutrons on a moving grating. Lines of 0, +1 and +2 diffraction orders were simultaneously recorded, which had previously been impossible to be done by other methods. These results have made it possible to make a comparison with the recent theoretical calculations based on the dynamical theory of neutron diffraction on a moving phase grating.

  8. Development of Soft Ionization for Particulate Organic Detection with the Aerodyne Aerosol Mass Spectrometer

    SciTech Connect

    Trimborn, A; Williams, L R; Jayne, J T; Worsnop, D R

    2008-06-19

    During this DOE SBIR Phase II project, we have successfully developed several soft ionization techniques, i.e., ionization schemes which involve less fragmentation of the ions, for use with the Aerodyne time-of-flight aerosol mass spectrometer (ToF-AMS). Vacuum ultraviolet single photon ionization was demonstrated in the laboratory and deployed in field campaigns. Vacuum ultraviolet single photon ionization allows better identification of organic species in aerosol particles as shown in laboratory experiments on single component particles, and in field measurements on complex multi-component particles. Dissociative electron attachment with lower energy electrons (less than 30 eV) was demonstrated in the measurement of particulate organics in chamber experiments in Switzerland, and is now a routine approach with AMS systems configured for bipolar, negative ion detection. This technique is particularly powerful for detection of acidic and other highly oxygenated secondary organic aerosol (SOA) chemical functionality. Low energy electron ionization (10 to 12 eV) is also a softer ionization approach routinely available to AMS users. Finally, Lithium ion attachment has been shown to be sensitive to more alkyl-like chemical functionality in SOA. Results from Mexico City are particularly exciting in observing changes in SOA molecular composition under different photochemical/meteorological conditions. More recent results detecting biomass burns at the Montana fire lab have demonstrated quantitative and selective detection of levoglucosan. These soft ionization techniques provide the ToF-AMS with better capability for identifying organic species in ambient atmospheric aerosol particles. This, in turn, will allow more detailed study of the sources, transformations and fate of organic-containing aerosol.

  9. Characterization of organic aerosols in Beijing using an aerodyne high-resolution aerosol mass spectrometer

    NASA Astrophysics Data System (ADS)

    Zhang, Junke; Wang, Yuesi; Huang, Xiaojuan; Liu, Zirui; Ji, Dongsheng; Sun, Yang

    2015-06-01

    Fine particle of organic aerosol (OA), mostly arising from pollution, are abundant in Beijing. To achieve a better understanding of the difference in OA in summer and autumn, a high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS, Aerodyne Research Inc., USA) was deployed in urban Beijing in August and October 2012. The mean OA mass concentration in autumn was 30±30 μg m-3, which was higher than in summer (13±6.9 μg m-3). The elemental analysis found that OA was more aged in summer (oxygen-to-carbon (O/C) ratios were 0.41 and 0.32 for summer and autumn, respectively). Positive matrix factorization (PMF) analysis identified three and five components in summer and autumn, respectively. In summer, an oxygenated OA (OOA), a cooking-emission-related OA (COA), and a hydrocarbon-like OA (HOA) were indentified. Meanwhile, the OOA was separated into LV-OOA (low-volatility OOA) and SV-OOA (semi-volatile OOA); and in autumn, a nitrogen-containing OA (NOA) was also found. The SOA (secondary OA) was always the most important OA component, accounting for 55% of the OA in the two seasons. Back trajectory clustering analysis found that the origin of the air masses was more complex in summer. Southerly air masses in both seasons were associated with the highest OA loading, while northerly air masses were associated with the lowest OA loading. A preliminary study of OA components, especially the POA (primary OA), in different periods found that the HOA and COA all decreased during the National Day holiday period, and HOA decreased at weekends compared with weekdays.

  10. Video Guidance Sensor and Time-of-Flight Rangefinder

    NASA Technical Reports Server (NTRS)

    Bryan, Thomas; Howard, Richard; Bell, Joseph L.; Roe, Fred D.; Book, Michael L.

    2007-01-01

    A proposed video guidance sensor (VGS) would be based mostly on the hardware and software of a prior Advanced VGS (AVGS), with some additions to enable it to function as a time-of-flight rangefinder (in contradistinction to a triangulation or image-processing rangefinder). It would typically be used at distances of the order of 2 or 3 kilometers, where a typical target would appear in a video image as a single blob, making it possible to extract the direction to the target (but not the orientation of the target or the distance to the target) from a video image of light reflected from the target. As described in several previous NASA Tech Briefs articles, an AVGS system is an optoelectronic system that provides guidance for automated docking of two vehicles. In the original application, the two vehicles are spacecraft, but the basic principles of design and operation of the system are applicable to aircraft, robots, objects maneuvered by cranes, or other objects that may be required to be aligned and brought together automatically or under remote control. In a prior AVGS system of the type upon which the now-proposed VGS is largely based, the tracked vehicle is equipped with one or more passive targets that reflect light from one or more continuous-wave laser diode(s) on the tracking vehicle, a video camera on the tracking vehicle acquires images of the targets in the reflected laser light, the video images are digitized, and the image data are processed to obtain the direction to the target. The design concept of the proposed VGS does not call for any memory or processor hardware beyond that already present in the prior AVGS, but does call for some additional hardware and some additional software. It also calls for assignment of some additional tasks to two subsystems that are parts of the prior VGS: a field-programmable gate array (FPGA) that generates timing and control signals, and a digital signal processor (DSP) that processes the digitized video images. The

  11. Chern Numbers Hiding in Time of Flight Images

    NASA Astrophysics Data System (ADS)

    Satija, Indubala; Zhao, Erhai; Ghosh, Parag; Bray-Ali, Noah

    2011-03-01

    Since the experimental realization of synthetic magnetic fields in neural ultracold atoms, transport measurement such as quantized Hall conductivity remains an open challenge. Here we propose a novel and feasible scheme to measure the topological invariants, namely the chern numbers, in the time of flight images. We study both the commensurate and the incommensurate flux, with the later being the main focus here. The central concept underlying our proposal is the mapping between the chern numbers and the size of the dimerized states that emerge when the two-dimensional hopping is tuned to the highly anisotropic limit. In a uncoupled double quantum Hall system exhibiting time reversal invariance, only odd-sized dimer correlation functions are non-zero and hence encode quantized spin current. Finally, we illustrate that inspite of highly fragmented spectrum, a finite set of chern numbers are meaningful. Our results are supported by direct numerical computation of transverse conductivity. NBA acknowledges support from a National Research Council postdoctoral research associateship.

  12. Time-of-flight observation of electron swarm in methane

    SciTech Connect

    Hasegawa, H.; Date, H.; Yoshida, K.; Shimozuma, M.

    2009-06-01

    This paper reports on the evolution of an isolated electron swarm, which is experimentally observed as spatial distributions at every moment. This observation is assumed to directly correspond to the conventional time-of-flight theory. We have measured the spatial distribution of electrons using a double-shutter technique in the drift tube, where a shutter electrode to collect electrons can be slid along the field (E/N) direction in order to capture a relative electron number at a certain range of location. As a typical parameter defined by this spatial distribution, the center-of-mass drift velocity (W{sub r}) is determined for methane gas. The result is compared with the mean-arrival-time drift velocity (W{sub m}) defined from the arriving electron number at fixed positions. We have also performed a theoretical analysis in which a Fourier transformed Boltzmann equation is solved to deduce both of the drift velocities from a dispersion relationship. The difference between W{sub r} and W{sub m} at high E/Ns (above 200 Td) is clearly ascertained in the experimental and theoretical investigations, which is attributable to the occurrence of ionization events.

  13. Update on time-of-flight PET imaging

    PubMed Central

    Surti, Suleman

    2015-01-01

    Time-of-flight (TOF) PET was initially introduced in the early days of PET. TOF PET scanners developed in the 1980s had limited sensitivity and spatial resolution, operated in 2D mode with septa, and used analytic image reconstruction methods. Current generation of TOF PET scanners have the highest sensitivity and spatial resolution ever achieved in commercial whole-body PET, operate in fully-3D mode, and use iterative reconstruction with full system modeling. Previously, it was shown that TOF provides a gain in image signal-to-noise-ratio (SNR) that is proportional to the square root of the object size divided by the system timing resolution. With oncologic studies being the primary application of PET, more recent work has shown that in modern TOF PET scanners there is an improved trade-off between lesion contrast, image noise, and total imaging time, leading to a combination of improved lesion detectability, reduced scan time or injected dose, and more accurate and precise lesion uptake measurement. The benefit of TOF PET is also higher for heavier patients, which leads to a more uniform clinical performance over all patient sizes. PMID:25525181

  14. Studies of Electronic Stopping Powers Using Time of Flight Spectrometry

    SciTech Connect

    Zhang, Yanwen; Weber, William J.

    2004-06-01

    Determination of electronic stopping powers using Time of Flight (ToF) spectrometry have been demonstrated by measuring energy loss of He, O, and Al particles based on a ToF Elastic Recoil Detection Analysis (ERDA) set-up. In transmission geometry, the energy loss of the particles in self-supported stopping foils of C, Si and SiC is measured over a continuous range of energies using the ToF spectrometer. This study emphasizes the difference of the stopping power determination with and without dependence on the Si detector calibration over a wide energy range. By calibrating the Si detector for each channel over the measured energy region, the improved approach eliminates much of the error associated with pulsed height defects and measurement uncertainties of less than 4% are achieved. Stopping powers from this study are compared with limited experimental data from the literature and SRIM (The Stopping and Range of Ions in Matter) 2000 and 2003 predictions. In general, the predicted values are in reasonable agreement with the experimental data, and an improved accuracy of SRIM 2003 over SRIM 2000 can be observed in some cases. Furthermore, Braggs rule is valid in SiC for O and Al over the energy region studied.

  15. The diamond time of flight detector of the TOTEM experiment

    NASA Astrophysics Data System (ADS)

    Berretti, Mirko

    2017-02-01

    This contribution describes the design and the performance of a novel timing detector developed by the TOTEM Collaboration. The detector will be installed inside the TOTEM Roman Pots (RPs) and will measure the Time-Of-Flight (TOF) of the protons produced in the central diffractive (CD) interactions at the LHC. In particular, the measurement of the proton TOF allows the determination of the vertex longitudinal position where the protons are produced, thus allowing the protons association with one of the vertices reconstructed by the CMS detectors. The TOF detector is based on single crystal CVD (scCVD) diamond plates and it is designed in order to measure the protons TOF with 50 ps time resolution. To achieve this performance, a dedicated fast and low noise electronics for the signal amplification has been developed. Indeed, while diamond sensors have lower noise and faster signals than silicon sensors, the amount of charge released in the medium is lower. The digitization of the diamond signal is performed sampling the waveform at 10 GSa/s with the SAMPIC chip. The performance of the first TOF detector installed in the LHC in November 2015 will be reported. An overview of the clock distribution system and of the control system which interfaces the timing detectors to the experiment DAQ is finally given.

  16. Performance of the Tachyon Time-of-Flight PET Camera.

    PubMed

    Peng, Q; Choong, W-S; Vu, C; Huber, J S; Janecek, M; Wilson, D; Huesman, R H; Qi, Jinyi; Zhou, Jian; Moses, W W

    2015-02-01

    We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon's detector module is optimized for timing by coupling the 6.15 × 25 mm(2) side of 6.15 × 6.15 × 25 mm(3) LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/- ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. The results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3.

  17. Performance of the Tachyon Time-of-Flight PET Camera

    PubMed Central

    Peng, Q.; Choong, W.-S.; Vu, C.; Huber, J. S.; Janecek, M.; Wilson, D.; Huesman, R. H.; Qi, Jinyi; Zhou, Jian; Moses, W. W.

    2015-01-01

    We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon’s detector module is optimized for timing by coupling the 6.15 × 25 mm2 side of 6.15 × 6.15 × 25 mm3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/− ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. The results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3. PMID:26594057

  18. Performance of the Tachyon Time-of-Flight PET Camera

    DOE PAGES

    Peng, Q.; Choong, W. -S.; Vu, C.; ...

    2015-01-23

    We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon's detector module is optimized for timing by coupling the 6.15 ×25 mm2 side of 6.15 ×6.15 ×25 mm3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMAmore » NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/- 20 ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. We find that the results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3.« less

  19. Time-of-flight photoconductivity in polymer/graphene blends

    NASA Astrophysics Data System (ADS)

    Bratina, Gvido; Pavlica, Egon; Pathipati, Srinivasa Rao; Nawrocki, Robert; Penumala, Raveendra

    2015-03-01

    We have used time-of-flight (TOF) photoconductivity measurements to assess the electric charge transport parameters in thin layers of poly(3-hexyl thiophene-2,5-diyl) (P3HT) mixed with single and multiple-layer graphene nanoflakes. Thin layers were cast from a solution and two co-planar metal electrodes were deposited by vacuum evaporation on top. An electric field was set up between the electrodes A laser pulse was used to photogenerate charge carriers near the biased electrode, and time dependence of the photocurrent (I(t)) was measured at the opposite electrode. I(t) curves were confronted to I(t)s obtained by a Gaussian-disorder Monte Carlo simulations, adapted to thin-film geometry. The simulations included a position-dependent electric field between two coplanar electrodes, which importantly affects the charge carrier transport through the blend between the electrodes. Comparison between the simulated and measured I(t)s resulted in values for charge carrier mobility, average charge velocity and variation of charge velocity. Our results show that the hole mobility in blends is increased by more than an order of magnitude in comparison to the hole mobility of a neat layers of P3HT

  20. Performance of the Tachyon Time-of-Flight PET Camera

    SciTech Connect

    Peng, Q.; Choong, W. -S.; Vu, C.; Huber, J. S.; Janecek, M.; Wilson, D.; Huesman, R. H.; Qi, Jinyi; Zhou, Jian; Moses, W. W.

    2015-01-23

    We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon's detector module is optimized for timing by coupling the 6.15 ×25 mm2 side of 6.15 ×6.15 ×25 mm3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/- 20 ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. We find that the results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3.

  1. The high-resolution time-of-flight spectrometer TOFTOF

    NASA Astrophysics Data System (ADS)

    Unruh, Tobias; Neuhaus, Jürgen; Petry, Winfried

    2007-10-01

    The TOFTOF spectrometer is a multi-disc chopper time-of-flight spectrometer for cold neutrons at the research neutron source Heinz Maier-Leibnitz (FRM II). After five reactor cycles of routine operation the characteristics of the instrument are reported in this article. The spectrometer features an excellent signal to background ratio due to its remote position in the neutron guide hall, an elaborated shielding concept and an s-shaped curved primary neutron guide which acts i.a. as a neutron velocity filter. The spectrometer is fed with neutrons from the undermoderated cold neutron source of the FRM II leading to a total neutron flux of ˜1010n/cm2/s in the continuous white beam at the sample position distributed over a continuous and particularly broad wavelength spectrum. A high energy resolution is achieved by the use of high speed chopper discs made of carbon-fiber-reinforced plastic. In the combination of intensity, resolution and signal to background ratio the spectrometer offers new scientific prospects in the fields of inelastic and quasielastic neutron scattering.

  2. Two-step Laser Time-of-Flight Mass Spectrometry to Elucidate Organic Diversity in Planetary Surface Materials.

    NASA Technical Reports Server (NTRS)

    Getty, Stephanie A.; Brinckerhoff, William B.; Cornish, Timothy; Li, Xiang; Floyd, Melissa; Arevalo, Ricardo Jr.; Cook, Jamie Elsila; Callahan, Michael P.

    2013-01-01

    Laser desorption/ionization time-of-flight mass spectrometry (LD-TOF-MS) holds promise to be a low-mass, compact in situ analytical capability for future landed missions to planetary surfaces. The ability to analyze a solid sample for both mineralogical and preserved organic content with laser ionization could be compelling as part of a scientific mission pay-load that must be prepared for unanticipated discoveries. Targeted missions for this instrument capability include Mars, Europa, Enceladus, and small icy bodies, such as asteroids and comets.

  3. Results from the commissioning of a multi-modal endoscope for ultrasound and time of flight PET

    SciTech Connect

    Bugalho, Ricardo

    2015-07-01

    The EndoTOFPET-US collaboration has developed a multi-modal imaging system combining Ultrasound with Time-of-Flight Positron Emission Tomography into an endoscopic imaging device. The objective of the project is to obtain a coincidence time resolution of about 200 ps FWHM and to achieve about 1 mm spatial resolution of the PET system, while integrating all the components in a very compact detector suitable for endoscopic use. This scanner aims to be exploited for diagnostic and surgical oncology, as well as being instrumental in the clinical test of new biomarkers especially targeted for prostate and pancreatic cancer. (authors)

  4. Recent developments in time-of-flight PET.

    PubMed

    Vandenberghe, S; Mikhaylova, E; D'Hoe, E; Mollet, P; Karp, J S

    2016-12-01

    While the first time-of-flight (TOF)-positron emission tomography (PET) systems were already built in the early 1980s, limited clinical studies were acquired on these scanners. PET was still a research tool, and the available TOF-PET systems were experimental. Due to a combination of low stopping power and limited spatial resolution (caused by limited light output of the scintillators), these systems could not compete with bismuth germanate (BGO)-based PET scanners. Developments on TOF system were limited for about a decade but started again around 2000. The combination of fast photomultipliers, scintillators with high density, modern electronics, and faster computing power for image reconstruction have made it possible to introduce this principle in clinical TOF-PET systems. This paper reviews recent developments in system design, image reconstruction, corrections, and the potential in new applications for TOF-PET. After explaining the basic principles of time-of-flight, the difficulties in detector technology and electronics to obtain a good and stable timing resolution are shortly explained. The available clinical systems and prototypes under development are described in detail. The development of this type of PET scanner also requires modified image reconstruction with accurate modeling and correction methods. The additional dimension introduced by the time difference motivates a shift from sinogram- to listmode-based reconstruction. This reconstruction is however rather slow and therefore rebinning techniques specific for TOF data have been proposed. The main motivation for TOF-PET remains the large potential for image quality improvement and more accurate quantification for a given number of counts. The gain is related to the ratio of object size and spatial extent of the TOF kernel and is therefore particularly relevant for heavy patients, where image quality degrades significantly due to increased attenuation (low counts) and high scatter fractions. The

  5. Sensors for Using Times of Flight to Measure Flow Velocities

    NASA Technical Reports Server (NTRS)

    Fralick, Gutave; Wrbanek, John D.; Hwang, Danny; Turso, James

    2006-01-01

    Thin-film sensors for measuring flow velocities in terms of times of flight are undergoing development. These sensors are very small and can be mounted flush with surfaces of airfoils, ducts, and other objects along which one might need to measure flows. Alternatively or in addition, these sensors can be mounted on small struts protruding from such surfaces for acquiring velocity measurements at various distances from the surfaces for the purpose of obtaining boundary-layer flow-velocity profiles. These sensors are related to, but not the same as, hot-wire anemometers. Each sensor includes a thin-film, electrically conductive loop, along which an electric current is made to flow to heat the loop to a temperature above that of the surrounding fluid. Instantaneous voltage fluctuations in segments of the loop are measured by means of electrical taps placed at intervals along the loop. These voltage fluctuations are caused by local fluctuations in electrical resistance that are, in turn, caused by local temperature fluctuations that are, in turn, caused by fluctuations in flow-induced cooling and, hence, in flow velocity. The differential voltage as a function of time, measured at each pair of taps, is subjected to cross-correlation processing with the corresponding quantities measured at other pairs of taps at different locations on the loop. The cross-correlations yield the times taken by elements of fluid to travel between the pairs of taps. Then the component of velocity along the line between any two pairs of taps is calculated simply as the distance between the pairs of taps divided by the travel time. Unlike in the case of hot-wire anemometers, there is no need to obtain calibration data on voltage fluctuations versus velocity fluctuations because, at least in principle, the correlation times are independent of the calibration data.

  6. LVGEMS Time-of-Flight Mass Spectrometry on Satellites

    NASA Technical Reports Server (NTRS)

    Herrero, Federico

    2013-01-01

    NASA fs investigations of the upper atmosphere and ionosphere require measurements of composition of the neutral air and ions. NASA is able to undertake these observations, but the instruments currently in use have their limitations. NASA has extended the scope of its research in the atmosphere and now requires more measurements covering more of the atmosphere. Out of this need, NASA developed multipoint measurements using miniaturized satellites, also called nanosatellites (e.g., CubeSats), that require a new generation of spectrometers that can fit into a 4 4 in. (.10 10 cm) cross-section in the upgraded satellites. Overall, the new mass spectrometer required for the new depth of atmospheric research must fulfill a new level of low-voltage/low-power requirements, smaller size, and less risk of magnetic contamination. The Low-Voltage Gated Electrostatic Mass Spectrometer (LVGEMS) was developed to fulfill these requirements. The LVGEMS offers a new spectrometer that eliminates magnetic field issues associated with magnetic sector mass spectrometers, reduces power, and is about 1/10 the size of previous instruments. LVGEMS employs the time of flight (TOF) technique in the GEMS mass spectrometer previously developed. However, like any TOF mass spectrometer, GEMS requires a rectangular waveform of large voltage amplitude, exceeding 100 V -- that means that the voltage applied to one of the GEMS electrodes has to change from 0 to 100 V in a time of only a few nanoseconds. Such electronic speed requires more power than can be provided in a CubeSat. In the LVGEMS, the amplitude of the rectangular waveform is reduced to about 1 V, compatible with digital electronics supplies and requiring little power.

  7. Determination of aerosol ammonium using an aerodyne aerosol mass spectrometer

    NASA Astrophysics Data System (ADS)

    Delia, A. E.; Toohey, D. W.; Worsnop, D. R.

    2003-04-01

    The chemical composition of fine aerosols is a significant issue both because it influences the chemical and radiative properties of the aerosols, which in turn impact the regional and global climate and human health, and because it is difficult to measure accurately. The Aerosol Mass Spectrometer (AMS) developed by Aerodyne Research measures both chemical composition and aerodynamic size of submicron aerosols quantitatively. However, the measurement of aerosol ammonium is more difficult than that of the other major inorganic species, nitrate and sulfate, because of interferences in the mass spectrum from air and water. This presentation will describe the successful procedure developed for dealing with these interferences and accurately determining the ammonium mass. In addition, the application of this procedure to aerosols from a range of ambient conditions will be demonstrated using data from several field studies.

  8. Development of a Metastable Atom Bombardment (MAB) Source for Penning Ionization Time-of-flight Aerosol Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Robinson, C. B.; Kimmel, J. R.; David, D.; Jayne, J. T.; Trimborn, A.; Worsnop, D. R.; Jimenez, J. L.

    2009-12-01

    The Aerodyne time-of-flight aerosol mass spectrometer (ToF-AMS) utilizes thermal vaporization followed by electron ionization (EI) to convert aerosol components to gas-phase ions. The method enables quantification of chemical classes, but the extensive fragmentation caused by EI limits the specificity of both chemical analysis and source identification by factor analysis. To better identify the molecular components of aerosols, we have constructed a metastable atom bombardment (MAB) ionization source that can be interfaced to standard ToF-AMS hardware. A beam of metastable rare gas atoms is produced by a low-voltage DC discharge and focused toward the vaporization plume, yielding Penning Ionization of the analyte molecules. By changing gases, the excited energies of the metastables can be adjusted between 20.61 eV (He) and 9.92 eV (Kr). Source parameters, including pressures, current, geometry, and materials, were optimized for He, Ar, and Kr. Instrument sensitivity and induced fragmentation was characterized for each using lab-generated oleic acid particles. The demonstrated sensitivities are 0.1% of EI (3% of the SNR of EI in the V-mode, comparable to the Q-AMS SNR), which is sufficient for ambient monitoring. A metastable flux of 2.6e14 sr-1sec-1 has been achieved. The MAB-AMS has been deployed to the FLAME-3 campaign at the USDA Fire Sciences Laboratory in Missoula, MT, and used to sample smoke from open burning of different biomass samples. Preliminary results from FLAME-3 will be presented.

  9. Multiple-reflection time-of-flight mass spectrometry for in situ applications

    NASA Astrophysics Data System (ADS)

    Dickel, T.; Plaß, W. R.; Lang, J.; Ebert, J.; Geissel, H.; Haettner, E.; Jesch, C.; Lippert, W.; Petrick, M.; Scheidenberger, C.; Yavor, M. I.

    2013-12-01

    Multiple-reflection time-of-flight mass spectrometers (MR-TOF-MS) have recently been installed at different low-energy radioactive ion beam facilities. They are used as isobar separators with high ion capacity and as mass spectrometers with high mass resolving power and accuracy for short-lived nuclei. Furthermore, MR-TOF-MS have a huge potential for applications in other fields, such as chemistry, biology, medicine, space science, and homeland security. The development, commissioning and results of an MR-TOF-MS is presented, which serves as proof-of-principle to show that very high mass resolving powers (∼105) can be achieved in a compact device (length ∼30 cm). Based on this work, an MR-TOF-MS for in situ application has been designed. For the first time, this device combines very high mass resolving power (>105), mobility, and an atmospheric pressure inlet in one instrument. It will enable in situ measurements without sample preparation at very high mass accuracy. Envisaged applications of this mobile MR-TOF-MS are discussed.

  10. Combining endoscopic ultrasound with Time-Of-Flight PET: The EndoTOFPET-US Project

    NASA Astrophysics Data System (ADS)

    Frisch, Benjamin

    2013-12-01

    The EndoTOFPET-US collaboration develops a multimodal imaging technique for endoscopic exams of the pancreas or the prostate. It combines the benefits of high resolution metabolic imaging with Time-Of-Flight Positron Emission Tomography (TOF PET) and anatomical imaging with ultrasound (US). EndoTOFPET-US consists of a PET head extension for a commercial US endoscope and a PET plate outside the body in coincidence with the head. The high level of miniaturization and integration creates challenges in fields such as scintillating crystals, ultra-fast photo-detection, highly integrated electronics, system integration and image reconstruction. Amongst the developments, fast scintillators as well as fast and compact digital SiPMs with single SPAD readout are used to obtain the best coincidence time resolution (CTR). Highly integrated ASICs and DAQ electronics contribute to the timing performances of EndoTOFPET. In view of the targeted resolution of around 1 mm in the reconstructed image, we present a prototype detector system with a CTR better than 240 ps FWHM. We discuss the challenges in simulating such a system and introduce reconstruction algorithms based on graphics processing units (GPU).

  11. Fast-neutron Induced Reactions at the nELBE Time-of-flight Facility

    NASA Astrophysics Data System (ADS)

    Junghans, A. R.; Beyer, R.; Elekes, Z.; Grosse, E.; Hannaske, R.; Kögler, T.; Massarczyk, R.; Schwengner, R.; Wagner, A.

    2014-05-01

    The compact neutron-time-of-flight facility nELBE at the superconducting electron accelerator ELBE of Helmholtz-Zentrum Dresden-Rossendorf is being rebuilt and extended with a low-background experimental hall. The neutron radiator consists of a liquid lead circuit without additional neutron moderators. The useful neutron spectrum extends from some tens of keV to about 10 MeV. nELBE is intended to deliver cross section data of fast-neutron nuclear interactions e.g. for the transmutation of nuclear waste and improvement of neutron physical simulations of innovative nuclear systems. Before the extension of the facility, the photon production cross section of 56Fe was measured with an HPGe detector and the inelastic neutron scattering cross section to the first few excited states in 56Fe was determined. The neutron total cross sections of Au and Ta were determined in the energy from 200 keV to 7 MeV in a transmission experiment.

  12. Multi-capillary-column proton-transfer-reaction time-of-flight mass spectrometry.

    PubMed

    Ruzsanyi, Veronika; Fischer, Lukas; Herbig, Jens; Ager, Clemes; Amann, Anton

    2013-11-05

    Proton-transfer-reaction time-of-flight mass-spectrometry (PTR-TOFMS) exhibits high selectivity with a resolution of around 5000 m/Δm. While isobars can be separated with this resolution, discrimination of isomeric compounds is usually not possible. The coupling of a multi-capillary column (MCC) with a PTR-TOFMS overcomes these problems as demonstrated in this paper for the ketone isomers 3-heptanone and 2-methyl-3-hexanone and for different aldehydes. Moreover, fragmentation of compounds can be studied in detail which might even improve the identification. LODs for compounds tested are in the range of low ppbv and peak positions of the respective separated substances show good repeatability (RSD of the peak positions <3.2%). Due to its special characteristics, such as isothermal operation, compact size, the MCC setup is suitable to be installed inside the instrument and the overall retention time for a complete spectrum is only a few minutes: this allows near real-time measurements in the optional MCC mode. In contrast to other methods that yield additional separation, such as the use of pre-cursor ions other than H3O(+), this method yields additional information without increasing complexity.

  13. Multi-capillary-column proton-transfer-reaction time-of-flight mass spectrometry☆

    PubMed Central

    Ruzsanyi, Veronika; Fischer, Lukas; Herbig, Jens; Ager, Clemes; Amann, Anton

    2013-01-01

    Proton-transfer-reaction time-of-flight mass-spectrometry (PTR-TOFMS) exhibits high selectivity with a resolution of around 5000 m/Δm. While isobars can be separated with this resolution, discrimination of isomeric compounds is usually not possible. The coupling of a multi-capillary column (MCC) with a PTR-TOFMS overcomes these problems as demonstrated in this paper for the ketone isomers 3-heptanone and 2-methyl-3-hexanone and for different aldehydes. Moreover, fragmentation of compounds can be studied in detail which might even improve the identification. LODs for compounds tested are in the range of low ppbv and peak positions of the respective separated substances show good repeatability (RSD of the peak positions <3.2%). Due to its special characteristics, such as isothermal operation, compact size, the MCC setup is suitable to be installed inside the instrument and the overall retention time for a complete spectrum is only a few minutes: this allows near real-time measurements in the optional MCC mode. In contrast to other methods that yield additional separation, such as the use of pre-cursor ions other than H3O+, this method yields additional information without increasing complexity. PMID:24119758

  14. Investigation of a Multi-Anode Microchannel Plate PMT for Time-of-Flight PET.

    PubMed

    Choong, Woon-Seng

    2010-09-13

    We report on an investigation of a mulit-anode microchannel plate PMT for time-of-flight PET detector modules. The primary advantages of an MCP lie in its excellent timing properties (fast rise time and low transit time spread), compact size, and reasonably large active area, thus making it a good candidate for TOF applications. In addition, the anode can be segmented into an array of collection electrodes with fine pitch to attain good position sensitivity. In this paper, we investigate using the Photonis Planacon MCP-PMT with a pore size of 10 µm to construct a PET detector module, specifically for time-of-flight applications. We measure the single electron response by exciting the Planacon with pulsed laser diode. We also measure the performance of the Planacon as a PET detector by coupling a 4 mm × 4 mm × 10 mm LSO crystal to individual pixel to study its gain uniformity, energy resolution, and timing resolution. The rise time of the Planacon is 440 ps with pulse duration of about 1 ns. A transit time spread of 120 ps FWHM is achieved. The gain is fairly uniform across the central region of the Planacon, but drops off by as much as a factor of 2.5 around the edges. The energy resolution is fairly uniform across the Planacon with an average value of 18.6±0.7% FWHM. While the average timing resolution of 252±7 ps FWHM is achieved in the central region of the Planacon, it degrades to 280±9 ps FWHM for edge pixels and 316±15 ps FWHM for corner pixels. We compare the results with measurements performed with a fast timing conventional PMT (Hamamatsu R-9800). We find that the R9800, which has significantly higher PDE, has a better timing resolution than the Planacon. Furthermore, we perform detector simulations to calculate the improvement that can be achieved with a higher PDE Planacon. The calculation shows that the Planacon can achieve significantly better timing resolution if it can attain the same PDE as the R-9800, while only a 30% improvement is needed

  15. Concrete Infill Monitoring in Concrete-Filled FRP Tubes Using a PZT-Based Ultrasonic Time-of-Flight Method.

    PubMed

    Luo, Mingzhang; Li, Weijie; Hei, Chuang; Song, Gangbing

    2016-12-07

    Concrete-filled fiber-reinforced polymer tubes (CFFTs) have attracted interest for their structural applications in corrosive environments. However, a weak interfacial strength between the fiber-reinforced polymer (FRP) tube and the concrete infill may develop due to concrete shrinkage and inadequate concrete compaction during concrete casting, which will destroy the confinement effect and thereby reduce the load bearing capacity of a CFFT. In this paper, the lead zirconate titanate (PZT)-based ultrasonic time-of-flight (TOF) method was adopted to assess the concrete infill condition of CFFTs. The basic idea of this method is that the velocity of the ultrasonic wave propagation in the FRP material is about half of that in concrete material. Any voids or debonding created along the interface between the FRP tube and the concrete will delay the arrival time between the pairs of PZT transducers. A comparison of the arrival times of the PZT pairs between the intact and the defected CFFT was made to assess the severity of the voids or the debonding. The feasibility of the methodology was analyzed using a finite-difference time-domain-based numerical simulation. Experiments were setup to validate the numerical results, which showed good agreement with the numerical findings. The results showed that the ultrasonic time-of-flight method is able to detect the concrete infill condition of CFFTs.

  16. Endo-TOFPET-US: A multimodal ultrasonic probe featuring time of flight PET in diagnostic and therapeutic endoscopy

    NASA Astrophysics Data System (ADS)

    Meyer, T. C.; Endo-Tofpet-Us Collaboration

    2013-08-01

    This work outlines the functionality of a new medical instrument and describes the research and development work aiming at new and higher performance imaging techniques with Time of Flight-PET capability in endoscopy and surgical oncology. It focuses on the associated scientific and technological challenges to be met in fields such as scintillating crystallography, ultra-fast photo-detection, highly integrated electronics, and system integration. This will highlight possible answers and solutions that derive from techniques and instrumentation prominent in high energy physics. Special emphasis is put on new developments of scintillators and diffractive optics to increase light output, and fast and compact photodetectors such as silicon photomultipliers (SiPMs) with the option of single SPAD readout. In view of the targeted coincidence time of flight performance of 200 ps FWHM equivalent to 30 mm along the line of response (LOR), tests using cerium-calcium-co-doped LSO crystals of 10 mm length and commercial SiPMs from Hamamatsu already produced a coincidence time resolution (CTR) of better than 170 ps FWHM.

  17. Concrete Infill Monitoring in Concrete-Filled FRP Tubes Using a PZT-Based Ultrasonic Time-of-Flight Method

    PubMed Central

    Luo, Mingzhang; Li, Weijie; Hei, Chuang; Song, Gangbing

    2016-01-01

    Concrete-filled fiber-reinforced polymer tubes (CFFTs) have attracted interest for their structural applications in corrosive environments. However, a weak interfacial strength between the fiber-reinforced polymer (FRP) tube and the concrete infill may develop due to concrete shrinkage and inadequate concrete compaction during concrete casting, which will destroy the confinement effect and thereby reduce the load bearing capacity of a CFFT. In this paper, the lead zirconate titanate (PZT)-based ultrasonic time-of-flight (TOF) method was adopted to assess the concrete infill condition of CFFTs. The basic idea of this method is that the velocity of the ultrasonic wave propagation in the FRP material is about half of that in concrete material. Any voids or debonding created along the interface between the FRP tube and the concrete will delay the arrival time between the pairs of PZT transducers. A comparison of the arrival times of the PZT pairs between the intact and the defected CFFT was made to assess the severity of the voids or the debonding. The feasibility of the methodology was analyzed using a finite-difference time-domain-based numerical simulation. Experiments were setup to validate the numerical results, which showed good agreement with the numerical findings. The results showed that the ultrasonic time-of-flight method is able to detect the concrete infill condition of CFFTs. PMID:27941617

  18. Applying of the optical time-of-flight spectroscopy for the paper and pulp characterization

    NASA Astrophysics Data System (ADS)

    Pluciński, Jerzy

    2006-02-01

    The paper presents benefits of optical time-of-flight spectroscopy for the pulp and paper characterization. A semiconductor pulse laser and a streak camera as the photodetector were utilized in experimental part of research described in this paper. Distribution of the time of flight of photons through various kinds of wood pulp (e.g. pulp after mechanical treatment coming both fi-om tree species giving hard and soft wood and pulp after thermo-mechanical treatment) was measured. The pulp samples used in the measurements had consistency ranging from 0 to 5% of dry mass in the suspension. The influence of additives (kaolin, talc and calcium carbonate) present in the suspension on the time of flight distribution of photons was studied as well. Finally, dependence of the time of flight of photons through various kinds of the paper (i.e. newspaper, copy paper, and tissue) on the thickness of the sample was investigated.

  19. Equivalent flaw time-of-flight diffraction sizing with ultrasonic phased arrays

    NASA Astrophysics Data System (ADS)

    Engle, Brady J.; Schmerr, Lester W., Jr.; Sedov, Alexander

    2013-01-01

    Ultrasonic phased array transducers can be used to extend traditional time-of-flight diffraction (TOFD) crack sizing, resulting in more quantitative information about the crack being obtained. Traditional TOFD yields a single length parameter, while the equivalent flaw time-of-flight diffraction crack sizing method (EFTOFD) described here uses data from multiple look-angles to fit an equivalent degenerate ellipsoid to the crack. The size and orientation of the equivalent flaw can be used to estimate the actual crack size.

  20. Chemical Characteristics of Particulate Matter from Vehicle emission using High Resolution Time of Flight Aerosol Mass Spectrometer (HR-ToF-AMS)

    NASA Astrophysics Data System (ADS)

    Park, T.; Lee, T.; Kang, S.; Lee, J.; Kim, J.; Son, J.; Yoo, H. M.; Kim, K.; Park, G.

    2015-12-01

    Car emissions are major contributors of particulate matter (PM) in the urban environment and effects of air pollution, climate change, and human activities. By increasing of interest in research of car emission for assessment of the PM control, it became require to understand the chemical composition and characteristics of the car exhaust gases and particulate matter. To understand car emission characteristics of PM, we will study PM of car emissions for five driving modes (National Institute Environmental Research (NIER)-5, NIER-9, NIER-12, NIER-14) and three fixed speed driving modes (30km/h, 70km/h, 110km/h) using different fuel types (gasoline, diesel, and LPG) at Transportation Pollution Research Center (TPRC) of NIER in Incheon, South Korea. PM chemical composition of car emission was measured for concentrations of organics, sulfate, nitrate, ammonium, PAHs, oxidation states and size distribution using an Aerodyne High Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS) and engine exhaust particle sizer (EEPS) on real-time. In the study, organics concentration was dominated for all cases of driving modes and the concentration of organics was increased in 110km/h fixed speed mode for gasoline and diesel. The presentation will provide an overview of the chemical composition of PM in the car emissions.

  1. Automatic layout of integrated-optic time-of-flight circuits

    NASA Astrophysics Data System (ADS)

    Fogg, Ruth D.

    1996-11-01

    This work describes the architecture and algorithms used in the computer-aided design tool developed for the automatic layout of integrated-optic, time-of-flight circuit designs. As in VLSI circuit layout, total wire length and chip area minimization are the goals in the layout of time-of-flight circuits. However, there are two major differences between the layout of time of flight circuits and VLSI circuits. First, the interconnection lengths of time-of-flight designs are exactly specified in order to achieve the necessary delays for signal synchronization. SEcondly, the switching elements are 120 times longer than they are wide. This highly astigmatic aspect ratio causes severe constraints on how and where the switches are placed. Assuming the continued development of corner turning mirrors allows the use of a parallel, row-based device placement architecture and a rectangular, fixed-grid track system for the connecting paths. The layout process proceeds in two steps. The first step involves the use of a partial circuit graph representation to place the elements in rows, oriented in the direction of the signal flow. After iterative improvement of the placement, the second step proceeds with the routing of the connecting paths. The main problem in the automatic layout of time-of-flight circuits is achieving the correct path lengths without overlapping previously routed paths. This problem is solved by taking advantage of a certain degree of variability present in each path, allowing the use of simple heuristics to circumvent previously routed paths.

  2. High mass resolution isochronous time-of-flight spectrograph for three-dimensional space plasma measurements

    NASA Technical Reports Server (NTRS)

    Moebius, E.; Bochsler, P.; Ghielmetti, A. G.; Hamilton, D. C.

    1990-01-01

    By combining a toroidal electrostatic analyzer with a novel cylindrically symmetric isochronous time-of-flight mass spectrometer, an instrument was developed that simultaneously determines the three-dimensional distribution function of ions and differentiates species. The ion mass is determined to high resolution (M/Delta-M greater than 50) from the time of flight within a harmonic field configuration defined by hyperboloid equipotential surfaces. A second conventional time-of-flight channel makes use of particles leaving the thin entrance foil as neutrals. An additional solid state detector in which the neutrals are stopped allows the total energy and thereby the ionic charge of the incident ions to be determined as well. Information from the neutral and the ion channels can be combined to determine the total mass of an incident molecular ion and the mass of one atomic fragment.

  3. Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET.

    PubMed

    Jacobsen, A S; Salewski, M; Eriksson, J; Ericsson, G; Hjalmarsson, A; Korsholm, S B; Leipold, F; Nielsen, S K; Rasmussen, J; Stejner, M

    2014-11-01

    The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR.

  4. Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET

    SciTech Connect

    Jacobsen, A. S. Salewski, M.; Korsholm, S. B.; Leipold, F.; Nielsen, S. K.; Rasmussen, J.; Stejner, M.; Eriksson, J.; Ericsson, G.; Hjalmarsson, A.

    2014-11-15

    The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR.

  5. The ROTAX/DIFF time-of-flight diffractometer at ISIS

    NASA Astrophysics Data System (ADS)

    Tietze-Jaensch, H.; Kockelmann, W.; Schmidt, W.; Will, G.

    1997-02-01

    We report on the setup of the ROTAX instrument as a conventional angle-dispersive time-of-flight diffractometer. This utilisation of the instrument not only provides a powerful and very versatile tool for many bread-and-butter applications in crystallographic and magnetic structure determination but also exploits the methods of single-crystal diffraction of quasi-Laue and diffuse scattering. White beam neutron time-of-flight diffraction expands to a very economic way of obtaining pole figures for texture analysis in bulk-material and earth sciences. Generally speaking, an overall gain-factor of 5-10 is practically achieved compared to an equivalent constant wavelength instrument.

  6. Design, construction, characterization and use of a detector to measure time of flight of cosmic rays

    NASA Astrophysics Data System (ADS)

    Araujo, A. C.; Félix, J.

    2016-10-01

    In the study of cosmic rays, measurements of time of flight and momentum have been used to identify incident particles from its physical properties, like mass. In this poster we present the design, construction, characterization, and operation of a detector to measure time of flight of cosmic rays. The device is comprised of three plates of plastic scintillator arranged in vertical straight line, they are coupled to one photomultiplier tube. The analogical output has been connected to a data acquisition system to obtain the number of digital pulses per millisecond. We present preliminary results.

  7. Precision electronics for a system of custom MCPs in the TORCH Time of Flight detector

    NASA Astrophysics Data System (ADS)

    Gao, R.; Brook, N.; Castillo García, L.; Conneely, T.; Cussans, D.; Föhl, K.; Forty, R.; Frei, C.; Gys, T.; Harnew, N.; Piedigrossi, D.; Rademacker, J.; Ros García, A.; Van Dijk, M.

    2017-03-01

    The TORCH detector will provide charged particle pi/K/p identification up to 10 GeV/c, combining Time-of-Flight and Cherenkov techniques to achieve a timing resolution of 70 ps for single photons. Based on a scalable design, a Time-of-Flight electronics readout system has been developed to instrument a novel customized 512-channel Micro Channel Plate (MCP) device. A Gigabit Ethernet-based readout scheme that operates the TORCH demonstration unit consisting of ten such MCPs will be reported. The trigger and clock distribution will also be discussed.

  8. Single-photon pulsed-light indirect time-of-flight 3D ranging.

    PubMed

    Bellisai, S; Bronzi, D; Villa, F A; Tisa, S; Tosi, A; Zappa, F

    2013-02-25

    "Indirect" time-of-flight is one technique to obtain depth-resolved images through active illumination that is becoming more popular in the recent years. Several methods and light timing patterns are used nowadays, aimed at improving measurement precision with smarter algorithms, while using less and less light power. Purpose of this work is to present an indirect time-of-flight imaging camera based on pulsed-light active illumination and a 32 × 32 single-photon avalanche diode array with an improved illumination timing pattern, able to increase depth resolution and to reach single-photon level sensitivity.

  9. Fourier rebinning and consistency equations for time-of-flight PET planograms.

    PubMed

    Li, Yusheng; Defrise, Michel; Matej, Samuel; Metzler, Scott D

    2016-01-01

    Due to the unique geometry, dual-panel PET scanners have many advantages in dedicated breast imaging and on-board imaging applications since the compact scanners can be combined with other imaging and treatment modalities. The major challenges of dual-panel PET imaging are the limited-angle problem and data truncation, which can cause artifacts due to incomplete data sampling. The time-of-flight (TOF) information can be a promising solution to reduce these artifacts. The TOF planogram is the native data format for dual-panel TOF PET scanners, and the non-TOF planogram is the 3D extension of linogram. The TOF planograms is five-dimensional while the objects are three-dimensional, and there are two degrees of redundancy. In this paper, we derive consistency equations and Fourier-based rebinning algorithms to provide a complete understanding of the rich structure of the fully 3D TOF planograms. We first derive two consistency equations and John's equation for 3D TOF planograms. By taking the Fourier transforms, we obtain two Fourier consistency equations and the Fourier-John equation, which are the duals of the consistency equations and John's equation, respectively. We then solve the Fourier consistency equations and Fourier-John equation using the method of characteristics. The two degrees of entangled redundancy of the 3D TOF data can be explicitly elicited and exploited by the solutions along the characteristic curves. As the special cases of the general solutions, we obtain Fourier rebinning and consistency equations (FORCEs), and thus we obtain a complete scheme to convert among different types of PET planograms: 3D TOF, 3D non-TOF, 2D TOF and 2D non-TOF planograms. The FORCEs can be used as Fourier-based rebinning algorithms for TOF-PET data reduction, inverse rebinnings for designing fast projectors, or consistency conditions for estimating missing data. As a byproduct, we show the two consistency equations are necessary and sufficient for 3D TOF planograms

  10. Fourier rebinning and consistency equations for time-of-flight PET planograms

    NASA Astrophysics Data System (ADS)

    Li, Yusheng; Defrise, Michel; Matej, Samuel; Metzler, Scott D.

    2016-09-01

    Due to the unique geometry, dual-panel PET scanners have many advantages in dedicated breast imaging and on-board imaging applications since the compact scanners can be combined with other imaging and treatment modalities. The major challenges of dual-panel PET imaging are the limited-angle problem and data truncation, which can cause artifacts due to incomplete data sampling. The time-of-flight (TOF) information can be a promising solution to reduce these artifacts. The TOF planogram is the native data format for dual-panel TOF PET scanners, and the non-TOF planogram is the 3D extension of linogram. The TOF planograms is five-dimensional while the objects are three-dimensional, and there are two degrees of redundancy. In this paper, we derive consistency equations and Fourier-based rebinning algorithms to provide a complete understanding of the rich structure of the fully 3D TOF planograms. We first derive two consistency equations and John’s equation for 3D TOF planograms. By taking the Fourier transforms, we obtain two Fourier consistency equations (FCEs) and the Fourier-John equation (FJE), which are the duals of the consistency equations and John’s equation, respectively. We then solve the FCEs and FJE using the method of characteristics. The two degrees of entangled redundancy of the 3D TOF data can be explicitly elicited and exploited by the solutions along the characteristic curves. As the special cases of the general solutions, we obtain Fourier rebinning and consistency equations (FORCEs), and thus we obtain a complete scheme to convert among different types of PET planograms: 3D TOF, 3D non-TOF, 2D TOF and 2D non-TOF planograms. The FORCEs can be used as Fourier-based rebinning algorithms for TOF-PET data reduction, inverse rebinnings for designing fast projectors, or consistency conditions for estimating missing data. As a byproduct, we show the two consistency equations are necessary and sufficient for 3D TOF planograms. Finally, we give numerical

  11. Sensitivity Upgrades to the Idaho Accelerator Center Neutron Time of Flight Spectrometer

    SciTech Connect

    Thompson, S. J.; Kinlaw, M. T.; Harmon, J. F.; Wells, D. P.; Hunt, A. W.

    2007-10-26

    Past experiments have shown that discrimination between between fissionable and non-fissionable materials is possible using an interrogation technique that monitors for high energy prompt fission neutrons. Several recent upgrades have been made to the neutron time of flight spectrometer at the Idaho Accelerator Center with the intent of increasing neutron detection sensitivity, allowing for system use in nonproliferation and security applications.

  12. Estimating time and time-lag in time-of-flight velocimetry

    NASA Technical Reports Server (NTRS)

    Lading, L.

    1983-01-01

    Estimating time and time-lag in time-of-flight velocimeters is investigated. Statistics of a filtered Poisson point process is given. A Maximum Likelihood Estimator is compared with suboptimum estimators in terms of robustness. For a dominating background combined spatial and temporal processing can improve the robustness compared with purely temporal processing. Schemes for the spatial filters are given.

  13. Time-of-Flight Experiments in Molecular Motion and Electron-Atom Collision Kinematics

    ERIC Educational Resources Information Center

    Donnelly, Denis P.; And Others

    1971-01-01

    Describes a set of experiments for an undergraduate laboratory which demonstrates the relationship between velocity, mass, and temperature in a gas. The experimental method involves time-of-flight measurements on atoms excited to metastable states by electron impact. Effects resulting from recoil in the electron-atom collision can also be…

  14. Characterization of nanoparticles by matrix assisted laser desorption ionization time-of-flight mass spectrometry.

    PubMed

    Ramalinga, Uma; Clogston, Jeffrey D; Patri, Anil K; Simpson, John T

    2011-01-01

    Determining the molecular weight of nanoparticles can be challenging. The molecular weight characterization of dendrimers, for example, with varying covalent and noncovalent modifications is critical to their use as therapeutics. As such, we describe in this chapter a protocol for the analysis of these molecules by matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS).

  15. Multiple wavelength time-of-flight sensor based on time-correlated single-photon counting

    NASA Astrophysics Data System (ADS)

    Buller, Gerald S.; Harkins, Ross D.; McCarthy, Aongus; Hiskett, Philip A.; MacKinnon, Gordon R.; Smith, George R.; Sung, Raymond; Wallace, Andrew M.; Lamb, Robert A.; Ridley, Kevin D.; Rarity, John G.

    2005-08-01

    This article describes a time-of-flight sensor based on multiple pulsed laser sources which utilizes time-correlated single-photon counting. The sensor has demonstrated good performance at ranges of up to 17 km in daylight conditions. Analysis techniques were developed to examine the returns from targets containing more than one scattering surface.

  16. Four-Spot Time-Of-Flight Laser Anemometer For Turbomachinery

    NASA Technical Reports Server (NTRS)

    Wernet, Mark P.; Skoch, Gary J.

    1995-01-01

    Two-color, four-spot time-of-flight laser anemometer designed for measuring flow velocity within narrow confines of small centrifugal compressor. Apparatus well suited for measuring fast (typical speeds 160 to 700 m/s), highly turbulent gas flows in turbomachinery. Other potential applications include measurement of gas flows in pipelines and in flows from explosions.

  17. The time-of-flight system on the Goddard medium energy gamma-ray telescope

    NASA Technical Reports Server (NTRS)

    Ross, R. W.; Chesney, J. R.

    1979-01-01

    A scintillation counter time of flight system, incorporated into the Goddard 50 cm by 50 cm spark chamber gamma ray telescope is described. The system, which utilizes constant fractions timing and particle position compensation and digitizes up to 10 ns time differences to six bit accuracy in less than 500 ns is analyzed. The performance of this system during balloon flight is discussed.

  18. Identification of Bacteria Using Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry

    ERIC Educational Resources Information Center

    Kedney, Mollie G.; Strunk, Kevin B.; Giaquinto, Lisa M.; Wagner, Jennifer A.; Pollack, Sidney; Patton, Walter A.

    2007-01-01

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS or simply MALDI) has become ubiquitous in the identification and analysis of biomacromolecules. As a technique that allows for the molecular weight determination of otherwise nonvolatile molecules, MALDI has had a profound impact in the molecular…

  19. Laser desorption time-of-flight mass spectrometer DNA analyzer. Final report

    SciTech Connect

    Chen, C.H.W.; Martin, S.A.

    1997-02-01

    The objective of this project is the development of a laser desorption time-of-flight mass spectrometer DNA analyzer which can be broadly used for biomedical research. Tasks include: pulsed ion extraction to improve resolution; two-component matrices to enhance ionization; and solid phase DNA purification.

  20. Time-of-Flight Measurement of the Speed of Sound in a Metal Bar

    ERIC Educational Resources Information Center

    Ganci, Salvatore

    2016-01-01

    A simple setup was designed for a "time-of-flight" measurement of the sound speed in a metal bar. The experiment requires low cost components and is very simple to understand by students. A good use of it is as a demonstration experiment.

  1. Proceedings of the 1986 workshop on advanced time-of-flight neutron powder diffraction

    SciTech Connect

    Lawson, A.C.; Smith, K.

    1986-09-01

    This report contains abstracts of talks and summaries of discussions from a small workshop held to discuss the future of time-of-flight neutron powder diffraction and its implementation at the Los Alamos Neutron Scattering Center. 47 refs., 3 figs.

  2. Time-of-Flight Measurement of the Speed of Sound in Water

    ERIC Educational Resources Information Center

    Ganci, Salvatore

    2016-01-01

    A simple setup is designed to investigate a "time-of-flight" measurement of the speed of sound in water. This experiment only requires low cost components and is also very simple to understand by students. It could be easily used as a demonstration experiment.

  3. Automatic layout of integrated-optics time-of-flight circuits

    NASA Astrophysics Data System (ADS)

    Kennett-Fogg, Ruth D.

    1995-04-01

    This work describes the architecture and algorithms used in the computer aided design tool developed for the automatic layout of integrated optic, time of flight circuit designs. This is similar to the layout of electronic VLSI circuits, where total wire length and chip area minimization are the major goals. Likewise, total wire length and chip area minimization are also the goals in the layout of time of flight circuits. However, there are two major differences between the layout of time of flight circuits and VLSI circuits. First, the interconnection lengths of time of flight designs are exactly specified in order to achieve the necessary delays for signal synchronization. Secondly, the switching elements are 120 times longer than they are wide. This highly astigmatic aspect ratio causes severe constraints on how and where the switches are placed. The assumed development of integrated corner turning mirrors allows the use of a parallel, row based device placement architecture and a rectangular, fixed grid track system for the connecting paths. The layout process proceeds in two steps. The first step involves the use of a partial circuit graph representation to place the elements in rows, oriented in the direction of the signal flow. After iterative improvement of the placement, the second step proceeds with the routing of the connecting paths. The main problem in the automatic layout of time of flight circuits is achieving the correct path lengths without overlapping previously routed paths. This problem is solved by taking advantage of a certain degree of variability present in each path, allowing the use of simple heuristics to circumvent previously routed paths.

  4. Evaluation of the Laser Ablation of Transition Metals/Metal Compounds by Time-of-Flight and Optical Spectroscopy

    DTIC Science & Technology

    1993-01-01

    METAL COMPOUNDS BY TIME- OF -FLIGHT AND OPTICAL SPECTROSCOPY Terry L. Thiem, Lyn R. Watson, James A. Gardner, Rainer A. Dressier, Richard H. Salter and...AD-A267 275 77:.>- June 30, 1993 Reprint Evaluation of tie Laser Ablation of Transition Metals/ Metal Compounds by Time- of -Flight and Optical ...are generated as measured using time- of -flight spectroscopy . The energy range can be controlled with the laser power, similar to studies conducted on

  5. Matrix-assisted laser desorption/ionization time-of-flight/time-of-flight tandem mass spectra of poly(butylene adipate).

    PubMed

    Rizzarelli, Paola; Puglisi, Concetto; Montaudo, Giorgio

    2006-01-01

    Matrix-assisted laser desorption/ionization time-of-flight/time-of-flight tandem mass spectrometry (MALDI-TOF/TOF-MS/MS) was employed to analyze four poly(butylene adipate) (PBAd) oligomers and to investigate their fragmentation pathways as a continuation of our work on the MALDI-TOF/TOF-MS/MS study of synthetic polymers. MALDI-TOF/TOF-MS/MS analysis was performed on oligomers terminated by carboxyl and hydroxyl groups, methyl adipate and hydroxyl groups, dihydroxyl groups, and dicarboxyl groups. The sodium adducts of these oligomers were selected as precursor ions. Different end groups do not influence the fragmentation of sodiated polyester oligomers and similar series of product ions were observed in all the MALDI-TOF/TOF-MS/MS spectra. According to the structures of the most abundant product ions identified in the present work, three fragmentation pathways have been proposed to occur most frequently in PBAd: beta-hydrogen-transfer rearrangement, leading to the selective cleavage of the --O--CH(2)-- bonds; --CH(2)--CH(2)-- (beta--beta) bond cleavage in the adipate moiety; and ester bond scission.

  6. Invited Article: Characterization of background sources in space-based time-of-flight mass spectrometers

    SciTech Connect

    Gilbert, J. A.; Gershman, D. J.; Gloeckler, G.; Lundgren, R. A.; Zurbuchen, T. H.; Orlando, T. M.; McLain, J.; Steiger, R. von

    2014-09-15

    For instruments that use time-of-flight techniques to measure space plasma, there are common sources of background signals that evidence themselves in the data. The background from these sources may increase the complexity of data analysis and reduce the signal-to-noise response of the instrument, thereby diminishing the science value or usefulness of the data. This paper reviews several sources of background commonly found in time-of-flight mass spectrometers and illustrates their effect in actual data using examples from ACE-SWICS and MESSENGER-FIPS. Sources include penetrating particles and radiation, UV photons, energy straggling and angular scattering, electron stimulated desorption of ions, ion-induced electron emission, accidental coincidence events, and noise signatures from instrument electronics. Data signatures of these sources are shown, as well as mitigation strategies and design considerations for future instruments.

  7. Invited article: Characterization of background sources in space-based time-of-flight mass spectrometers.

    PubMed

    Gilbert, J A; Gershman, D J; Gloeckler, G; Lundgren, R A; Zurbuchen, T H; Orlando, T M; McLain, J; von Steiger, R

    2014-09-01

    For instruments that use time-of-flight techniques to measure space plasma, there are common sources of background signals that evidence themselves in the data. The background from these sources may increase the complexity of data analysis and reduce the signal-to-noise response of the instrument, thereby diminishing the science value or usefulness of the data. This paper reviews several sources of background commonly found in time-of-flight mass spectrometers and illustrates their effect in actual data using examples from ACE-SWICS and MESSENGER-FIPS. Sources include penetrating particles and radiation, UV photons, energy straggling and angular scattering, electron stimulated desorption of ions, ion-induced electron emission, accidental coincidence events, and noise signatures from instrument electronics. Data signatures of these sources are shown, as well as mitigation strategies and design considerations for future instruments.

  8. Digitizing data acquisition and time-of-flight pulse processing for ToF-ERDA

    NASA Astrophysics Data System (ADS)

    Julin, Jaakko; Sajavaara, Timo

    2016-01-01

    A versatile system to capture and analyze signals from multi channel plate (MCP) based time-of-flight detectors and ionization based energy detectors such as silicon diodes and gas ionization chambers (GIC) is introduced. The system is based on commercial digitizers and custom software. It forms a part of a ToF-ERDA spectrometer, which has to be able to detect recoil atoms of many different species and energies. Compared to the currently used analogue electronics the digitizing system provides comparable time-of-flight resolution and improved hydrogen detection efficiency, while allowing the operation of the spectrometer be studied and optimized after the measurement. The hardware, data acquisition software and digital pulse processing algorithms to suit this application are described in detail.

  9. Study of ultrasonic thermometry based on ultrasonic time-of-flight measurement

    NASA Astrophysics Data System (ADS)

    Jia, Ruixi; Xiong, Qingyu; Wang, Lijie; Wang, Kai; Shen, Xuehua; Liang, Shan; Shi, Xin

    2016-03-01

    Ultrasonic thermometry is a kind of acoustic pyrometry and it has been evolving as a new temperature measurement technology for various environment. However, the accurate measurement of the ultrasonic time-of-flight is the key for ultrasonic thermometry. In this paper, we study the ultrasonic thermometry technique based on ultrasonic time-of-flight measurement with a pair of ultrasonic transducers for transmitting and receiving signal. The ultrasonic transducers are installed in a single path which ultrasonic travels. In order to validate the performance of ultrasonic thermometry, we make a contrast about the absolute error between the measured temperature value and the practical one. With and without heater source, the experimental results indicate ultrasonic thermometry has high precision of temperature measurement.

  10. A Metrological Based Realization of Time-of-Flight Diffraction Technique

    NASA Astrophysics Data System (ADS)

    Mayworm, Ruan C.; Alvarenga, Andre V.; Costa-Felix, Rodrigo P. B.

    Time-of-Flight Diffraction (ToFD) is a technique of non-destructive testing by ultrasound used for detecting faults and discontinuities in different components. The development and implementation of this technique was based on ISO 16828:2012 (Non-Destructive testing - Ultrasonic Testing - Time-of-Flight Diffraction Technique as a method for Detection and Sizing of Discontinuities). Controlling the different characteristics of the system, from the specification of the ultrasonic characteristics, to the imaging technique, was possible to identify the sources of uncertainty and estimate the ToFD measurement uncertainty. For a 25 mm deep stainless steel test object, expanded uncertainties less than 0.5%(0.093 mm) was achieved with ToFD. For larger ultrasonic paths, the technique is able to depict even lower uncertainties, regarding some care are taken in the ultrasonic measurement setup.

  11. Time of flight in MUSE at PIM1 at Paul Scherrer Institute

    NASA Astrophysics Data System (ADS)

    Lin, Wan; Gilman, Ronald; MUSE Collaboration

    2016-09-01

    The MUSE experiment at PIM1 at Paul Scherrer Institute in Villigen, Switzerland, measures elastic scattering of electrons and muons from a liquid hydrogen target. The intent of the experiment is to deduce whether the radius of the proton is the same when determined from the two different particle types. Precision timing is an important aspect of the experiment, used to determine particle types, reaction types, and beam momentum. Here we present results for a test setup measuring time of flight between prototypes of two detector systems to be used in the experiment, compared to Geant4 simulations. The results demonstrate time of flight resolution better than 100 ps, and beam momentum determination at the level of a few tenths of a percent. Douglass Project for Rutgers Women in Math, Science & Engineering, National Science Foundation Grant 1306126 to Rutgers University.

  12. Time-of-flight measurement with femtosecond pulses for high precision ranging lidar

    NASA Astrophysics Data System (ADS)

    Lee, J.; Kim, Y.-J.; Lee, K.; Lee, S.; Kim, S.-W.

    2010-10-01

    The time-of-flight of light pulses has long been used as a direct measure of distance, but the state-of-the-art measurement precision using conventional light pulses or microwaves reaches only several hundreds of micromeres. This is due to the bandwidth limit of the photodetectors available today, which is in the picosecond range at best. Here, we improve the time-of-flight precision to the nanometer regime by timing femtosecond pulses through phase-locking control of the pulse repetition rate using the optical cross-correlation technique that exploits a second-harmonic birefringence crystal and a balance photodetector. The enhanced capability is maintained at long range without periodic ambiguity, being well suited to terrestrial lidar applications such as geodetic surveying, range finders and absolute altimeters. This method could also be applied to future space missions of formation-flying satellites for synthetic aperture imaging and remote experiments related to the general relativity theory.

  13. Nitrogen depth profiling using recoil-nucleus time-of-flight spectrometry

    SciTech Connect

    Welsh, J.F. Jr.; Schweikert, E.A.

    1994-12-31

    Neutron depth profiling (NDP) has been shown to be an effective research tool for the profiling of light elements. Significant increases in sensitivity like those realized at the cold neutron NDP facility at the National Institute of Standards and Technology (NIST) reactor continue to advance the technique. Previous work has also shown that the depth resolution of NDP could be improved by measuring (via time of flight) the kinetic energies of recoil nuclei emitted during (n,p) and (n, {alpha}) reactions. The purpose of this work was to extend the technique of recoil-nucleus time-of-flight (TOF) NDP (RN-TOF-NDP) to the profiling of nitrogen in silicon nitride using the {sup 14}N(n,p) {sup 14}C reaction.

  14. Ambient aerosol analysis using aerosol-time-of-flight mass spectrometry

    SciTech Connect

    Prather, K.A.; Noble, C.A.; Liu, D.Y.; Silva, P.J.; Fergenson, D.F.

    1996-10-01

    We have recently developed a technique, Aerosol-Time-of-Flight Mass Spectrometry (ATOFMS), which is capable of real-time determination of the aerodynamic size and chemical composition of individual aerosol particles. In order to obtain such information, the techniques of aerodynamic particle sizing and time-of-flight mass spectrometry are combined in a single instrument. ATOFMS is being used for the direct analysis of ambient aerosols with the goal of establishing correlations between particle size and chemical composition. Currently, measurements are being made to establish potential links between the presence of particular types of particles with such factors as the time of day, weather conditions, and concentration levels of gaseous smog components such as NO{sub x} and ozone. This data will be used to help establish a better understanding of tropospheric gas-aerosol processes. This talk will discuss the operating principles of ATOFMS as well as present the results of ambient analysis studies performed in our laboratory.

  15. Detection system for high-resolution gamma radiation spectroscopy with neutron time-of-flight filtering

    DOEpatents

    Dioszegi, Istvan; Salwen, Cynthia; Vanier, Peter

    2014-12-30

    A .gamma.-radiation detection system that includes at least one semiconductor detector such as HPGe-Detector, a position-sensitive .alpha.-Detector, a TOF Controller, and a Digitizer/Integrator. The Digitizer/Integrator starts to process the energy signals of a .gamma.-radiation sent from the HPGe-Detector instantly when the HPGe-Detector detects the .gamma.-radiation. Subsequently, it is determined whether a coincidence exists between the .alpha.-particles and .gamma.-radiation signal, based on a determination of the time-of-flight of neutrons obtained from the .alpha.-Detector and the HPGe-Detector. If it is determined that the time-of-flight falls within a predetermined coincidence window, the Digitizer/Integrator is allowed to continue and complete the energy signal processing. If, however, there is no coincidence, the Digitizer/Integrator is instructed to be clear and reset its operation instantly.

  16. Time of flight measurements of unirradiated and irradiated nuclear graphite under cyclic compressive load

    NASA Astrophysics Data System (ADS)

    Bodel, W.; Atkin, C.; Marsden, B. J.

    2017-04-01

    The time-of-flight technique has been used to investigate the stiffness of nuclear graphite with respect to the grade and grain direction. A loading rig was developed to collect time-of-flight measurements during cycled compressive loading up to 80% of the material's compressive strength and subsequent unloading of specimens along the axis of the applied stress. The transmission velocity (related to Young's modulus), decreased with increasing applied stress; and depending on the graphite grade and orientation, the modulus then increased, decreased or remained constant upon unloading. These tests were repeated while observing the microstructure during the load/unload cycles. Initial decreases in transmission velocity with compressive load are attributed to microcrack formation within filler and binder phases. Three distinct types of behaviour occur on unloading, depending on the grade, irradiation, and loading direction. These different behaviours can be explained in terms of the material microstructure observed from the microscopy performed during loading.

  17. Limitation of Time-of-Flight Resolution in the Ultra High Mass Range

    PubMed Central

    Lee, Jeonghoon

    2011-01-01

    In this work, we have examined the reason for the deterioration of resolution and mass accuracy of time-of-flight mass analyzers with increasing mass after the expansion induced kinetic energy has been eliminated by collisional cooling in an ion guide. Theoretically, removing the expansion–induced kinetic energy by collisional cooling permits the ions to travel along the ion guide axes without significant deviation so that they can be injected into the analyzer in a well-collimated ion beam with well-defined kinetic energy. If the ions can be injected into an orthogonal acceleration time-of-flight mass analyzer (oa-TOF) in this manner, high resolution mass analysis can be obtained regardless of mass or m/z. Unfortunately, high resolution did not result. It is our contention that the effusive expansion out of the first ion guide yields dispersive axial ejection that reduces TOF resolving power with increasing mass not m/z. PMID:21728303

  18. Development of An Ion-Drift Time-of-Flight Chemical Ionization Mass Spectrometry Technique for Measurements of Aerosol Precursor Gases

    NASA Astrophysics Data System (ADS)

    Zheng, J.; Ma, Y.; Chen, M.

    2012-12-01

    We have developed a new technique, i.e., ion-drift time-of-flight chemical ionization mass spectrometry (ID-ToF-CIMS) for measurements of aerosol precursor gases, including ammonia, amines, organic acids and oxygenated VOCs at pptv level with a response time less than 1 s. The ID-ToF-CIMS was modified from an Aerodyne high resolution ToF-CIMS with a custom-designed ion-drift tube, which can control the ion flight velocity and hence the ion-molecular reaction time. In addition, the tunable electric field generated by the drift tube can break up water clusters to select the major reagent ions. The advantages of the ID-ToF-CIMS over the traditional quadrupole-based ID-CIMS were the high mass-resolving power of the ToF mass analyzer and the capability of simultaneous measurement of the full mass range (typically up to 300 m/z) of product ions. Using hydronium ion based reagent ions, we demonstrated that the ID-ToF-CIMS can unambiguously measure ammonia (NH3) at 18.03 m/z, methyl amine (CH3NH2) at 32.05 m/z, formic acid (HCOOH) at 47.01 m/z and acetone (CH3COCH3) at 59.05 m/z. Calibrations were performed with both compressed commercial standard gases and permeation tubes and the results showed that the instrument detection limit can reach pptv level for 1 s average time or less. The ID-ToF-CIMS was also field tested in a mobile laboratory on the campus of Nanjing University of Information Science & Technology (NUIST). The preliminary results will be discussed.

  19. Comparison between triple quadrupole, time of flight and hybrid quadrupole time of flight analysers coupled to liquid chromatography for the detection of anabolic steroids in doping control analysis.

    PubMed

    Pozo, Oscar J; Van Eenoo, Peter; Deventer, Koen; Elbardissy, Hisham; Grimalt, Susana; Sancho, Juan V; Hernandez, Felix; Ventura, Rosa; Delbeke, Frans T

    2011-01-17

    Triple quadrupole (QqQ), time of flight (TOF) and quadrupole-time of flight (QTOF) analysers have been compared for the detection of anabolic steroids in human urine. Ten anabolic steroids were selected as model compounds based on their ionization and the presence of endogenous interferences. Both qualitative and quantitative analyses were evaluated. QqQ allowed for the detection of all analytes at the minimum required performance limit (MRPL) established by the World Anti-Doping Agency (between 2 and 10 ng mL(-1) in urine). TOF and QTOF approaches were not sensitive enough to detect some of the analytes (3'-hydroxy-stanozolol or the metabolites of boldenone and formebolone) at the established MRPL. Although a suitable accuracy was obtained, the precision was unsatisfactory (RSD typically higher than 20%) for quantitative purposes irrespective of the analyser used. The methods were applied to 30 real samples declared positives either for the misuse of boldenone, stanozolol and/or methandienone. Most of the compounds were detected by every technique, however QqQ was necessary for the detection of some metabolites in a few samples. Finally, the possibility to detect non-target steroids has been explored by the use of TOF and QTOF. The use of this approach revealed that the presence of boldenone and its metabolite in one sample was due to the intake of androsta-1,4,6-triene-3,17-dione. Additionally, the intake of methandienone was confirmed by the post-target detection of a long-term metabolite.

  20. Implementation of a new type of time-of-flight laser anemometer

    NASA Technical Reports Server (NTRS)

    Wernet, M. P.; Edwards, R. V.

    1986-01-01

    A new time-of-flight (TOF) laser anemometer system utilizing a spatial lead-lag filter for bipolar pulse generation has been constructed and tested. This new TOF has been modified to enable measurements in turbulent flows near walls. Good results have been obtained as close as 100 microns from a surface, with a 140-mm focal length final lens. Lading's theory for the behavior of the measurement variance has been confirmed for this configuration.

  1. Parameters’ Covariance in Neutron Time of Flight Analysis – Explicit Formulae

    SciTech Connect

    Odyniec, M.; Blair, J.

    2014-12-01

    We present here a method that estimates the parameters’ variance in a parametric model for neutron time of flight (NToF). The analytical formulae for parameter variances, obtained independently of calculation of parameter values from measured data, express the variances in terms of the choice, settings, and placement of the detector and the oscilloscope. Consequently, the method can serve as a tool in planning a measurement setup.

  2. Neutron xyz - polarization analysis at a time-of-flight instrument

    SciTech Connect

    Ehlers, Georg; Stewart, John Ross; Andersen, Ken

    2015-01-01

    When implementing a dedicated polarization analysis setup at a neutron time-of-flight instrument with a large area detector, one faces enormous challenges. Nevertheless, significant progress has been made towards this goal over the last few years. This paper addresses systematic limitations of the traditional method that is used to make these measurements, and a possible strategy to overcome these limitations. This will be important, for diffraction as well as inelastic experiments, where the scattering occurs mostly out-of-plane.

  3. Fully digital data acquisition system for the neutron time-of-flight spectrometer TOFOR at JET.

    PubMed

    Skiba, M; Weiszflog, M; Hjalmarsson, A; Ericsson, G; Hellesen, C; Conroy, S; Andersson-Sundén, E; Eriksson, J; Binda, F

    2012-10-01

    A prototype of a fully digital data acquisition system based on 1 Gsps 12 bit digitizers for the TOFOR fusion neutron spectrometer at JET is assessed. The prototype system enables the use of geometry-based background discrimination techniques, which are modeled, evaluated, and compared to experimental data. The experimental results are in line with the models and show a significant improvement in signal-to-background ratio in measured time-of-flight spectrum compared to the existing data acquisition system.

  4. Semen quality detection using time of flight and acoustic wave sensors

    SciTech Connect

    Newton, M. I.; Evans, C. R.; Simons, J. J.; Hughes, D. C.

    2007-04-09

    The authors report a real-time technique for assessing the number of motile sperm in a semen sample. The time of flight technique uses a flow channel with detection at the end of the channel using quartz crystal microbalances. Data presented suggest that a simple rigid mass model may be used in interpreting the change in resonant frequency using an effective mass for the sperm.

  5. Implementation of a new type of time-of-flight laser anemometer.

    PubMed

    Wernet, M P; Edwards, R V

    1986-03-01

    A new time-of-flight (TOF) laser anemometer system utilizing a spatial lead-lag filter for bipolar pulse generation has been constructed and tested. This new TOF has been modified to enable measurements in turbulent flows near walls. Good results have been obtained as close as 100 microm from a surface, with a 140-mm focal length final lens. Lading's theory for the behavior of the measurement variance has been confirmed for this configuration.

  6. Neutron-induced fission measurements at the time-of-flight facility nELBE

    SciTech Connect

    Kögler, T.; Junghans, A. R.; Massarczyk, R.; Schwengner, R.; Wagner, A.

    2015-05-18

    Neutron-induced fission of ²⁴²Pu is studied at the photoneutron source nELBE. The relative fast neutron fission cross section was determined using actinide fission chambers in a time-of-flight experiment. A good agreement of present nuclear data with evalua- tions has been achieved in the range of 100 keV to 10 MeV.

  7. Contactless flow measurement in liquid metal using electromagnetic time-of-flight method

    NASA Astrophysics Data System (ADS)

    Dubovikova, Nataliia; Resagk, Christian; Karcher, Christian; Kolesnikov, Yuri

    2016-05-01

    Measuring flow rates of liquid metal flows is of utmost importance in industrial applications such as metal casting, in order to ensure process efficiency and product quality. A non-contact method for flow rate control is described here. The method is known as time-of-flight Lorentz force velocimetry (LFV) and determines flow rate through measurement of Lorentz force that act on magnet systems that are placed close to the flow. In this method, a vortex generator is used to generate an eddy in the flow, with two magnet systems separated by a known distance placed downstream of the vortex generator. Each of the magnet systems has a force sensor attached to them which detects the passing of the eddy through its magnetic field as a significant perturbation in the force signal. The flow rate is estimated from the time span between the perturbations in the two force signals. In this paper, time-of-flight LFV technique is demonstrated experimentally for the case of liquid metal flow in a closed rectangular duct loop that is driven by an electromagnetic pump. A liquid metal alloy of gallium (Ga), indium (In) and tin (Sn)—GaInSn—is used as the working fluid. In contrast to prior works, for the first time, three-dimensional strain gauge force sensors were used for measuring Lorentz force to investigate the effect of flow disturbances in different directions for flow measurements by the time-of-flight LFV method. A prototype time-of-flight LFV flowmeter is developed, the operation of which in laboratory conditions is characterised by different experiments.

  8. The time-of-flight spectrometer with cold neutrons at the FRM-II

    NASA Astrophysics Data System (ADS)

    Zirkel, A.; Roth, S.; Schneider, W.; Neuhaus, J.; Petry, W.

    2000-03-01

    We are presenting a design study of the new cold-time-of-flight spectrometer to be built at the FRM-II. Monte Carlo techniques were used to optimize the flux at the sample position and to calculate the elastic energy resolution. A doubly focusing neutron guide is used to enhance the intensity on the sample. Magnetic bearings and carbon fiber composite disks will give access to very high chopper speeds, thereby considerably increasing the overall performance of the instrument.

  9. A New Neutron Time-of-Flight Array for β-Decay Studies

    NASA Astrophysics Data System (ADS)

    Sénoville, M.; Delaunay, F.; Achouri, N. L.; Pârlog, M.; Orr, N. A.; Cano-Ott, D.; Carniol, B.; Étasse, D.; Fontbonne, C.; Fontbonne, J. M.; Gibelin, J.; Hommet, J.; Laurent, B.; Ledoux, X.; Marqués, F. M.; Martínez, T.; De Séréville, N.

    A new time-of-flight array for β-delayed neutron spectroscopy (En < 5 MeV) is being developed with the aim of improved performance compared to existing arrays. We report on the status of this development, in particular the study of the n-γ discrimination quality with digital electronics, a comparison of several organic scintillators, including new discriminating plastics, as well as the characterisation of detectors with monoenergetic neutrons to measure intrinsic efficiencies and cross-talk probabilities.

  10. Acetazolamide challenge for three-dimensional time-of-flight MR angiography of the brain

    SciTech Connect

    Mandai, Kenji; Sueyoshi, Kenji; Fukunaga, Ryuzo; Nukada, Masaru; Ohtani, Fumio; Araki, Yutaka; Tsukaguchi, Isao; Abe, Hiroshi )

    1994-04-01

    We compared three-dimensional time-of-flight MR angiograms obtained before and after acetazolamide administration to evaluate whether use of this drug could improve visualization of small peripheral intracranial arteries and atherosclerotic stenosis. For evaluation of small peripheral arteries, 10 patients with clinical diagnosis of ischemic cerebrovascular disease and 10 healthy volunteers were investigated, and for evaluation of stenosis, another 6 patients were investigated. Vascular images were obtained by three-dimensional time-of-flight MR angiography. After a baseline scan, 17 mg/kg acetazolamide was injected intravenously and the second scan was performed 20 minutes later. Several small peripheral arteries that had not been seen on the baseline images were visible on the acetazolamide images without any augmentation of the background signals. Stenotic lesions in the main trunks of the major cerebral arteries were detected more clearly on acetazolamide images. Acetazolamide improves visualization of small peripheral intracranial arteries and sensitivity in detecting atherosclerotic stenosis in the main trunk of major cerebral artery by three-dimensional time-of-flight MR angiography without changing MR apparatus and software. 15 refs., 5 figs., 2 tabs.

  11. Nanometer scale elemental analysis in the helium ion microscope using time of flight spectrometry.

    PubMed

    Klingner, N; Heller, R; Hlawacek, G; von Borany, J; Notte, J; Huang, J; Facsko, S

    2016-03-01

    Time of flight backscattering spectrometry (ToF-BS) was successfully implemented in a helium ion microscope (HIM). Its integration introduces the ability to perform laterally resolved elemental analysis as well as elemental depth profiling on the nm scale. A lateral resolution of ≤54nm and a time resolution of Δt≤17ns(Δt/t≤5.4%) are achieved. By using the energy of the backscattered particles for contrast generation, we introduce a new imaging method to the HIM allowing direct elemental mapping as well as local spectrometry. In addition laterally resolved time of flight secondary ion mass spectrometry (ToF-SIMS) can be performed with the same setup. Time of flight is implemented by pulsing the primary ion beam. This is achieved in a cost effective and minimal invasive way that does not influence the high resolution capabilities of the microscope when operating in standard secondary electron (SE) imaging mode. This technique can thus be easily adapted to existing devices. The particular implementation of ToF-BS and ToF-SIMS techniques are described, results are presented and advantages, difficulties and limitations of this new techniques are discussed.

  12. Picosecond resolution on relativistic heavy ions' time-of-flight measurement

    NASA Astrophysics Data System (ADS)

    Ebran, A.; Taieb, J.; Belier, G.; Chatillon, A.; Laurent, B.; Martin, J.-F.; Pellereau, E.

    2013-11-01

    We developed a time-of-flight measurement system for relativistic heavy ions with a requested resolution of 40 ps Full Width Half Maximum. Such a resolution is mandatory to assign the correct mass number to every fission fragment, identified using the Bρ-ToF-ΔE method with the recoil spectrometer designed for the SOFIA experiment-which hold very recently at GSI. To achieve such a performance, fast plastic scintillators read-out by dedicated photomultiplier tubes were chosen among other possible options. We have led several test-measurements from 2009 to 2011, in order to investigate: the effect of the addition of a quenching molecule in the scintillator's matrix, the influence of the detector's size and the impact of the photomultiplier tube. The contribution of the dedicated electronics is also characterized. Time-of-flight measurements were performed realized with electron pulses and relativistic heavy ions, respectively provided by the LASER driven electron-accelerator (ELSA) at CEA-DAM Ile-de-France and by the SIS18/FRS facility at GSI. The reported results exhibit a time resolution better than 20 ps Full Width Half Maximum reached with the last prototype at GSI with an Uranium beam. These results confirm that the SOFIA experiment should enable the measurement of the relativistic fission fragments' time-of-flight with the requested resolution.

  13. (A new time of flight) Acoustic flow meter using wide band signals and adaptive beamforming techniques

    NASA Astrophysics Data System (ADS)

    Murgan, I.; Ioana, C.; Candel, I.; Anghel, A.; Ballester, J. L.; Reeb, B.; Combes, G.

    2016-11-01

    In this paper we present the result of our research concerning the improvement of acoustic time of flight flow metering for water pipes. Current flow meters are based on the estimation of direct time of flight by matched filtering of the received and emitted signals by acoustic transducers. Currently, narrow band signals are used, as well as a single emitter/receptor transducer configuration. Although simple, this configuration presents a series of limitations such as energy losses due to pipe wall/water interface, pressure/flow transients, sensitivity to flow induced vibrations, acoustic beam deformations and shift due to changes in flow velocity and embedded turbulence in the flow. The errors associated with these limitations reduce the overall robustness of existing flow meters, as well as the measured flow rate range and lower accuracy. In order to overcome these limitations, two major innovations were implemented at the signal processing level. The first one concerns the use of wide band signals that optimise the power transfer throughout the acoustic path and also increase the number of velocity/flow readings per second. Using wide band signals having a high duration-bandwidth product increases the precision in terms of time of flight measurements and, in the same time, improves the system robustness. The second contribution consists in the use of a multiple emitter - multiple receivers configuration (for one path) in order to compensate the emitted acoustic beam shift, compensate the time of flight estimation errors and thus increase the flow meter's robustness in case of undesired effects such as the “flow blow” and transient/rapid flow rate/velocity changes. Using a new signal processing algorithm that take advantage of the controlled wide band content coming from multiple receivers, the new flow meters achieves a higher accuracy in terms of flow velocity over a wider velocity range than existing systems. Tests carried out on real scale experimental

  14. A 3D profile function suitable for integration of neutron time-of-flight single crystal diffraction peaks

    NASA Astrophysics Data System (ADS)

    Gutmann, Matthias J.

    2017-03-01

    A 3D profile function is presented suitable to integrate reflections arising in time-of-flight (TOF) single crystal neutron diffraction experiments. In order to account for the large asymmetry of the peak shape in the TOF direction, a 3D Gaussian ellipsoid in the pixel (x, z) and time-of-flight coordinates is convoluted with a rising and falling exponential along the time-of-flight direction. An analytic expression is derived, making it suitable for least-squares fitting. The application of this function in detector space or reciprocal space is straightforward.

  15. Quasi-dynamic mode of nanomembranes for time-of-flight mass spectrometry of proteins

    NASA Astrophysics Data System (ADS)

    Park, Jonghoo; Kim, Hyunseok; Blick, Robert H.

    2012-03-01

    Mechanical resonators realized on the nano-scale by now offer applications in mass-sensing of biomolecules with extraordinary sensitivity. The general idea is that perfect mechanical biosensors should be of extremely small size to achieve zeptogram sensitivity in weighing single molecules similar to a balance. However, the small scale and long response time of weighing biomolecules with a cantilever restrict their usefulness as a high-throughput method. Commercial mass spectrometry (MS) such as electro-spray ionization (ESI)-MS and matrix-assisted laser desorption/ionization (MALDI)-time of flight (TOF)-MS are the gold standards to which nanomechanical resonators have to live up to. These two methods rely on the ionization and acceleration of biomolecules and the following ion detection after a mass selection step, such as time-of-flight (TOF). Hence, the spectrum is typically represented in m/z, i.e. the mass to ionization charge ratio. Here, we describe the feasibility and mass range of detection of a new mechanical approach for ion detection in time-of-flight mass spectrometry, the principle of which is that the impinging ion packets excite mechanical oscillations in a silicon nitride nanomembrane. These mechanical oscillations are henceforth detected via field emission of electrons from the nanomembrane. Ion detection is demonstrated in MALDI-TOF analysis over a broad range with angiotensin, bovine serum albumin (BSA), and an equimolar protein mixture of insulin, BSA, and immunoglobulin G (IgG). We find an unprecedented mass range of operation of the nanomembrane detector.

  16. Shotgun collision-induced dissociation of peptides using a time of flight mass analyzer.

    PubMed

    Purvine, Samuel; Eppel, Jason-Thomas; Yi, Eugene C; Goodlett, David R

    2003-06-01

    Parallel collision-induced dissociation (CID) of peptides rather than serial, as is customary, results in loss of the obvious parent-fragment ion lineage available from CID on a single ion. We report proof-of-principle results suggesting the feasibility of parallel peptide CID, referred to here as shotgun CID, for protein identification when using the measured mass accuracies available from a time of flight mass analyzer and currently available search routines such as SEQUEST. Additionally, we report that parent-fragment ion lineage may be reconstructed from information encoded in the chromatographic single ion current traces of peptides.

  17. Time of flight measurement of speed of sound in air with a computer sound card

    NASA Astrophysics Data System (ADS)

    Aljalal, Abdulaziz

    2014-11-01

    A computer sound card and freely available audio editing software are used to measure accurately the speed of sound in air using the time-of-flight method. In addition to speed of sound measurement, inversion behaviour upon reflection from an open and closed end of a pipe is demonstrated. Also, it is demonstrated that the reflection at an open end of a pipe occurs slightly outside the pipe. The equipment needed is readily available to any student with access to a microphone, loudspeaker and computer.

  18. Theory and operation of a three-gate time-of-flight velocity analyzer

    NASA Technical Reports Server (NTRS)

    Martus, K. E.; Orient, O. J.; Hodges, R. R.; Chutjian, A.

    1993-01-01

    Theoretical considerations and test results are presented for a new-type velocity analyzer for incident fast neutral particles, positive ions, and negative ions. Velocity analysis is carried out by means of a pulsed, three-gate time-of-flight (TOF) technique capable of eliminating alias velocities (harmonics) to sixth order. In addition the design and operation are presented of a four-element ion lens system, with small spherical and chromatic aberrations, suitable for interfacing a large-diameter ion beam from the TOF section with a subsequent mass analyzer.

  19. Effect of electron beam pulse width on time-of-flight spectra

    NASA Technical Reports Server (NTRS)

    Misakian, M.; Mumma, M. J.

    1974-01-01

    A simple but useful formula describing the effect of electron gun pulse width on the time of flight (TOF) spectra measured in translational spectroscopy experiments is developed. An approximately monoenergetic pulsed electrostatically focused electron beam traverses a scattering cell filled with a Maxwellian gas. Inelastic electron collisions with the gas produce metastable particles, ions, scattered electrons, and photons which then pass through a collimating slit system at right angles to the electron beam. TOF techniques are used to separate the photon signal from the metastable particle signal and to measure the TOF distribution of the metastable species.

  20. Effect of trapped ions in a gated time-of-flight apparatus

    NASA Technical Reports Server (NTRS)

    Martus, K. E.; Orient, O. J.; Chutjian, A.

    1993-01-01

    A three-mesh gate is used in a time-of-flight (TOF) apparatus to analyze the velocity of positive ions. Test results and a theoretical description are presented of an effect arising from trapping ions between meshes of a two-gate TOF velocity analyzer. The entrapped ions produce a side peak in the TOF spectra corresponding to faster ions. The onset and relative height of the side peak is dependent on the gating voltage and risetime of the pulsing electronics, while the relative intensity depends upon the velocity being sampled and the ratio of the gate width to duration.

  1. TIME-OF-FLIGHT MASS MEASUREMENTS AND THEIR IMPORTANCE FOR NUCLEAR ASTROPHYSICS

    SciTech Connect

    Matos, M.; Shapira, Dan

    2009-01-01

    Atomic masses play an important role in nuclear astrophysics. The lack of experimental values for nuclides of interest has triggered a rapid development of new mass measurement devices around the world, including Time-of-Flight (TOF) mass measurements offering an access to the most exotic nuclides. Recently, the TOF-B rho technique that includes a position measurement for magnetic rigidity correction has been implemented at the NSCL. An experiment with a similar TOF-B rho technique is approved and planned at the next generation radioactive beam facility (RIBF) at RIKEN.

  2. Electron pair emission detected by time-of-flight spectrometers: Recent progress

    SciTech Connect

    Huth, Michael; Schumann, Frank O.; Chiang, Cheng-Tien; Trützschler, Andreas; Kirschner, Jürgen; Widdra, Wolf

    2014-02-10

    We present results for electron coincidence spectroscopy using two time-of-flight (ToF) spectrometers. Excited by electron impact, the energy and momentum distribution of electron pairs emitted from the Cu(111) surface are resolved and a spectral feature related to the Shockley surface state is identified. By combining the two ToF spectrometers with a high-order harmonic generation light source, we demonstrate double photoemission spectroscopy in the laboratory that required synchrotron radiation in the past. Utilizing this setup, we report results for (γ,2e) on NiO(001) on Ag(001) excited with light at 30 eV photon energy.

  3. Time-of-flight velocity analysis of atomic and molecular beams

    NASA Technical Reports Server (NTRS)

    Hagena, O. F.; Varma, A. K.

    1968-01-01

    Conditions required for resolving a given beam speed distribution were evaluated by calculating the time-of-flight (TOF) signal for a finite open time of the beam shutter. Design criteria for a beam chopper and detection system are discussed in terms of the resolution, the range of speeds to be measured, and the optimum signal to noise ratio. A TOF system for detection of high intensity molecular beams with large speed ratios, as well as for low intensity scattered beams, is described. Experimental results are presented.

  4. A composition analyzer for microparticles using a spark ion source. [using time of flight spectrometers

    NASA Technical Reports Server (NTRS)

    Auer, S. O.; Berg, O. E.

    1975-01-01

    Iron microparticles were fired onto a capacitor-type microparticle detector which responded to an impact with a spark discharge. Ion currents were extracted from the spark and analyzed in a time-of-flight mass spectrometer. The mass spectra showed the element of both detector and particle materials. The total extracted ion currents was typically 10A within a period of 100ns, indicating very efficient vaporization of the particle and ionization of the vapor. Potential applications include research on cosmic dust, atmospheric aerosols and cloud droplets, particles ejected by rocket or jet engines, by machining processes, or by nuclear bomb explosions.

  5. Use of a large time-compensated scintillation detector in neutron time-of-flight measurements

    DOEpatents

    Goodman, Charles D.

    1979-01-01

    A scintillator for neutron time-of-flight measurements is positioned at a desired angle with respect to the neutron beam, and as a function of the energy thereof, such that the sum of the transit times of the neutrons and photons in the scintillator are substantially independent of the points of scintillations within the scintillator. Extrapolated zero timing is employed rather than the usual constant fraction timing. As a result, a substantially larger scintillator can be employed that substantially increases the data rate and shortens the experiment time.

  6. Analysis of the neutron time-of-flight spectra from inertial confinement fusion experiments

    DOE PAGES

    Hatarik, R.; Sayre, D. B.; Caggiano, J. A.; ...

    2015-11-12

    For a long time, neutron time-of-flight diagnostics been used to characterize the neutron spectrum produced by inertial confinement fusion experiments. The primary diagnostic goals are to extract the d+t→n+α (DT) and d+d→n+³He (DD) neutron yields and peak widths, and the amount DT scattering relative to its unscattered yield, which is also known as the down-scatter ratio (DSR). These quantities are used to infer yield weighted plasma conditions, such as ion temperature (Tion) and cold fuel areal density. We explain such novel methodologies used to determine neutron yield, apparent Tion and DSR.

  7. Integration of neutron time-of-flight single-crystal Bragg peaks in reciprocal space

    SciTech Connect

    Schultz, Arthur J; Joergensen, Mads; Wang, Xiaoping; Mikkelson, Ruth L; Mikkelson, Dennis J; Lynch, Vickie E; Peterson, Peter F; Green, Mark L; Hoffmann, Christina

    2014-01-01

    The intensity of single crystal Bragg peaks obtained by mapping neutron time-of-flight event data into reciprocal space and integrating in various ways are compared. These include spherical integration with a fixed radius, ellipsoid fitting and integrating of the peak intensity and one-dimensional peak profile fitting. In comparison to intensities obtained by integrating in real detector histogram space, the data integrated in reciprocal space results in better agreement factors and more accurate atomic parameters. Furthermore, structure refinement using integrated intensities from one-dimensional profile fitting is demonstrated to be more accurate than simple peak-minus-background integration.

  8. Stopping power measurements with the Time-of-Flight (ToF) technique

    DOE PAGES

    Fontana, Cristiano L.; Chen, Chien-Hung; Crespillo, Miguel L.; ...

    2015-11-10

    In our review of measurements of the stopping power of ions in matter is presented along with new measurements of the stopping powers of O, Si, Ti, and Au ions in self-supporting thin foils of SiO2, Nb2O5, and Ta2O5. Moreover, a Time-of-Flight system at the Ion Beam Materials Laboratory at the University of Tennessee, Knoxville, was used in transmission geometry in order to reduce experimental uncertainties. Finally, the resulting stopping powers show good precision and accuracy and corroborate previously quoted values in the literature. New stopping data are determined.

  9. Note: A novel dual-channel time-of-flight mass spectrometer for photoelectron imaging spectroscopy

    SciTech Connect

    Qin Zhengbo; Wu Xia; Tang Zichao

    2013-06-15

    A novel dual-channel time-of-flight mass spectrometer (D-TOFMS) has been designed to select anions in the photoelectron imaging measurements. In this instrument, the radiation laser can be triggered precisely to overlap with the selected ion cloud at the first-order space focusing plane. Compared with that of the conventional single channel TOFMS, the in situ mass selection performance of D-TOFMS is significantly improved. Preliminary experiment results are presented for the mass-selected photodetachment spectrum of F{sup -} to demonstrate the capability of the instrument.

  10. A Low-cost, Lightweight, and Miniaturized Time-of-flight Mass Spectrometer (TOFMS)

    NASA Technical Reports Server (NTRS)

    Srivastava, S. K.

    1993-01-01

    Time-of-flight mass spectrometers (TOFMS) are commonly used for mass analysis and for the measurement of energy distributions of charged particles. For achieving high mass and energy resolution these instruments generally comprise long flight tubes, often as long as a few meters. This necessitates high voltages and a very clean environment. These requirements make them bulky and heavy. We have developed an instrument and calibration techniques that are based on the design principles of TOFMS. However, instead of one long flight tube it consists of a series of cylindrical electrostatic lenses that confine ions under study along the axis of the flight tube.

  11. Time-of-Flight Mass Measurements and Their Importance for Nuclear Astrophysics

    NASA Astrophysics Data System (ADS)

    Matoš, M.; Estrade, A.; Amthor, A. M.; Bazin, D.; Becerril, A.; Elliot, T.; Famiano, M.; Gade, A.; Galaviz, D.; Lorusso, G.; Pereira, J.; Portillo, M.; Rogers, A.; Schatz, H.; Shapira, D.; Smith, E.; Stolz, A.; Wallace, M.

    2009-03-01

    Atomic masses play an important role in nuclear astrophysics. The lack of experimental values for nuclides of interest has triggered a rapid development of new mass measurement devices around the world, including Time-of-Flight (TOF) mass measurements offering an access to the most exotic nuclides. Recently, the TOF-Brho technique that includes a position measurement for magnetic rigidity correction has been implemented at the NSCL. An experiment with a similar TOF-Brho technique is approved and planned at the next generation radioactive beam facility (RIBF) at RIKEN.

  12. TORCH - Cherenkov and Time-of-Flight PID Detector for the LHCb Upgrade at CERN

    NASA Astrophysics Data System (ADS)

    Föhl, K.; Brook, N.; Castillo García, L.; Conneely, T.; Cussans, D.; Forty, R.; Frei, C.; Gao, R.; Gys, T.; Harnew, N.; Milnes, J.; Piedigrossi, D.; Rademacker, J.; Ros Garcì a, A.; van Dijk, M.

    2016-05-01

    TORCH is a large-area precision time-of-flight detector, based on Cherenkov light production and propagation in a quartz radiator plate, which is read out at its edges. TORCH is proposed for the LHCb experiment at CERN to provide positive particle identification for kaons, and is currently in the Research-and-Development phase. A brief overview of the micro-channel plate photon sensor development, the custom-made electronics, and an introduction to the current test beam activities is given. Optical readout solutions are presented for the potential use of BaBar DIRC bar boxes as part of the TORCH configuration in LHCb.

  13. Analysis of the neutron time-of-flight spectra from inertial confinement fusion experiments

    SciTech Connect

    Hatarik, R.; Sayre, D. B.; Caggiano, J. A.; Phillips, T.; Eckart, M. J.; Bond, E. J.; Cerjan, C.; Grim, G. P.; Hartouni, E. P.; Knauer, J. P.; Mcnaney, J. M.; Munro, D. H.

    2015-11-12

    For a long time, neutron time-of-flight diagnostics been used to characterize the neutron spectrum produced by inertial confinement fusion experiments. The primary diagnostic goals are to extract the d+t→n+α (DT) and d+d→n+³He (DD) neutron yields and peak widths, and the amount DT scattering relative to its unscattered yield, which is also known as the down-scatter ratio (DSR). These quantities are used to infer yield weighted plasma conditions, such as ion temperature (Tion) and cold fuel areal density. We explain such novel methodologies used to determine neutron yield, apparent Tion and DSR.

  14. Testing a new NIF neutron time-of-flight detector with a bibenzyl scintillator on OMEGA.

    PubMed

    Glebov, V Yu; Forrest, C; Knauer, J P; Pruyne, A; Romanofsky, M; Sangster, T C; Shoup, M J; Stoeckl, C; Caggiano, J A; Carman, M L; Clancy, T J; Hatarik, R; McNaney, J; Zaitseva, N P

    2012-10-01

    A new neutron time-of-flight (nTOF) detector with a bibenzyl crystal as a scintillator has been designed and manufactured for the National Ignition Facility (NIF). This detector will replace a nTOF20-Spec detector with an oxygenated xylene scintillator currently operational on the NIF to improve the areal-density measurements. In addition to areal density, the bibenzyl detector will measure the D-D and D-T neutron yield and the ion temperature of indirect- and direct-drive-implosion experiments. The design of the bibenzyl detector and results of tests on the OMEGA Laser System are presented.

  15. Combined distance-of-flight and time-of-flight mass spectrometer

    DOEpatents

    Enke, Christie G; Ray, Steven J; Graham, Alexander W; Hieftje, Gary M; Barinaga, Charles J; Koppenaal, David W

    2014-02-11

    A combined distance-of-flight mass spectrometry (DOFMS) and time-of-flight mass spectrometry (TOFMS) instrument includes an ion source configured to produce ions having varying mass-to-charge ratios, a first detector configured to determine when each of the ions travels a predetermined distance, a second detector configured to determine how far each of the ions travels in a predetermined time, and a detector extraction region operable to direct portions of the ions either to the first detector or to the second detector.

  16. A silicon photomultiplier readout for time of flight neutron spectroscopy with {gamma}-ray detectors

    SciTech Connect

    Pietropaolo, A.; Gorini, G.; Festa, G.; Andreani, C.; De Pascale, M. P.; Reali, E.; Grazzi, F.; Schooneveld, E. M.

    2009-09-15

    The silicon photomultiplier (SiPM) is a recently developed photosensor used in particle physics, e.g., for detection of minimum ionizing particles and/or Cherenkov radiation. Its performance is comparable to that of photomultiplier tubes, but with advantages in terms of reduced volume and magnetic field insensitivity. In the present study, the performance of a gamma ray detector made of an yttrium aluminum perovskite scintillation crystal and a SiPM-based readout is assessed for use in time of flight neutron spectroscopy. Measurements performed at the ISIS pulsed neutron source demonstrate the feasibility of {gamma}-detection based on the new device.

  17. Imaging time-of-flight secondary ion mass spectrometry of solid-phase peptide syntheses.

    PubMed

    Aubagnac, J L; Enjalbal, C; Drouot, C; Combarieu, R; Martinez, J

    1999-07-01

    Imaging time-of-flight secondary ion mass spectrometry (TOF-SIMS) of solid-phase peptide syntheses carried out by the Merrifield and Sheppard strategies is described. Mixtures of resin beads mixed at random from batch syntheses or obtained in combinatorial chemistry by the mix and split technique, where each bead is functionalized by a unique peptide, were analyzed directly without any chemical cleavage of the growing chains to assess the nature of the growing structure on any bead of the mixture without its isolation.

  18. Resolving multipath interference in time-of-flight imaging via modulation frequency diversity and sparse regularization.

    PubMed

    Bhandari, Ayush; Kadambi, Achuta; Whyte, Refael; Barsi, Christopher; Feigin, Micha; Dorrington, Adrian; Raskar, Ramesh

    2014-03-15

    Time-of-flight (ToF) cameras calculate depth maps by reconstructing phase shifts of amplitude-modulated signals. For broad illumination of transparent objects, reflections from multiple scene points can illuminate a given pixel, giving rise to an erroneous depth map. We report here a sparsity-regularized solution that separates K interfering components using multiple modulation frequency measurements. The method maps ToF imaging to the general framework of spectral estimation theory and has applications in improving depth profiles and exploiting multiple scattering.

  19. Quantum time-of-flight measurements: Kicked clock versus continuous clock

    SciTech Connect

    Alonso, Daniel; Sala Mayato, R.; Muga, J.G.

    2003-03-01

    The measurement of time durations or instants of occurrence of events has been frequently modeled 'operationally' by coupling the system of interest to a ''clock.'' According to several of these models, the operational approach is limited at low energies because the perturbation of the clock does not allow to reproduce accurately the corresponding ideal time quantity, defined for the system in isolation. We show that, for a time-of-flight measurement model that can be set to measure dwell or arrival times, these limitations may be overcome by extending the range of energies where the clock works properly using pulsed couplings rather than continuous ones.

  20. Solid Phase Microextraction and Miniature Time-of-Flight Mass Spectrometer

    SciTech Connect

    Hiller, j.m.

    1999-01-26

    A miniature mass spectrometer, based on the time-of-flight principle, has been developed for the detection of chemical warfare agent precursor molecules. The instrument, with minor modifications, could fulfill many of the needs for sensing organic molecules in various Defense Programs, including Enhanced Surveillance. The basic footprint of the instrument is about that of a lunch box. The instrument has a mass range to about 300, has parts-per-trillion detection limits, and can return spectra in less than a second. The instrument can also detect permanent gases and is especially sensitive to hydrogen. In volume, the device could be manufactured for under $5000.

  1. Detector response in time-of-flight mass spectrometry at high pulse repetition frequencies

    NASA Technical Reports Server (NTRS)

    Gulcicek, Erol E.; Boyle, James G.

    1993-01-01

    Dead time effects in chevron configured dual microchannel plates (MCPs) are investigated. Response times are determined experimentally for one chevron-configured dual MCP-type detector and two discrete dynode-type electron multipliers with 16 and 23 resistively divided stages. All of these detectors are found to be suitable for time-of-flight mass spectrometry (TOF MS), yielding 3-6-ns (FWHM) response times triggered on a single ion pulse. It is concluded that, unless there are viable solutions to overcome dead time disadvantages for continuous dynode detectors, suitable discrete dynode detectors for TOF MS appear to have a significant advantage for high repetition rate operation.

  2. Calibration of time of flight detectors using laser-driven neutron source

    SciTech Connect

    Mirfayzi, S. R.; Kar, S. Ahmed, H.; Green, A.; Alejo, A.; Jung, D.; Krygier, A. G.; Freeman, R. R.; Clarke, R.; Fuchs, J.; Vassura, L.; Kleinschmidt, A.; Roth, M.; Morrison, J. T.; Najmudin, Z.; Nakamura, H.; Norreys, P.; Oliver, M.; Zepf, M.; Borghesi, M.

    2015-07-15

    Calibration of three scintillators (EJ232Q, BC422Q, and EJ410) in a time-of-flight arrangement using a laser drive-neutron source is presented. The three plastic scintillator detectors were calibrated with gamma insensitive bubble detector spectrometers, which were absolutely calibrated over a wide range of neutron energies ranging from sub-MeV to 20 MeV. A typical set of data obtained simultaneously by the detectors is shown, measuring the neutron spectrum emitted from a petawatt laser irradiated thin foil.

  3. Identification of micro-organisms using superconducting tunnel junctions and time-of-flight mass spectrometry

    SciTech Connect

    Benner, W H; Frank, M; Horn, J M; Labov, S E; Langry, K; Ullom, J

    1999-08-30

    We present time-of-flight measurements of biological material ejected from complete bacterial spores following laser irradiation. Ion impacts are registered on a microchannel plate and on a Superconducting Tunnel Junction (STJ) detector. We compare mass spectra obtained with the two detectors. The STJ has better sensitivity to massive ions and also measures the energy of each ion. We show evidence that spores of different bacillus species produce distinctive mass spectra and associate the observed mass peaks with coat proteins identified through ion-exchange extraction and gel electrophoresis.

  4. Time-of-flight x-ray photoconductivity of HgI/sub 2/

    SciTech Connect

    Kurtz, S.R.; Hughes, R.C.; Ortale, C.; Schnepple, W.F.

    1987-11-15

    Time-of-flight photoconductivity measurements were performed on HgI/sub 2/ using a penetrating, pulsed x-ray source, simulating the operation of photoconductive x-ray detectors. By examining a variety of HgI/sub 2/ samples, a wide range of electron and hole mobilities were observed, but in all cases hole transport was highly localized, limiting the collection of the photocarriers in HgI/sub 2/ detectors. The intrinsic photocarrier generation and recombination processes differed from classical Onsager and Langevin mechanisms observed in low-mobility photoconductors.

  5. Time-of-flight compressed-sensing ultrafast photography for encrypted three-dimensional dynamic imaging

    NASA Astrophysics Data System (ADS)

    Liang, Jinyang; Gao, Liang; Hai, Pengfei; Li, Chiye; Wang, Lihong V.

    2016-02-01

    We applied compressed ultrafast photography (CUP), a computational imaging technique, to acquire three-dimensional (3D) images. The approach unites image encryption, compression, and acquisition in a single measurement, thereby allowing efficient and secure data transmission. By leveraging the time-of-flight (ToF) information of pulsed light reflected by the object, we can reconstruct a volumetric image (150 mm×150 mm×1050 mm, x × y × z) from a single camera snapshot. Furthermore, we demonstrated high-speed 3D videography of a moving object at 75 frames per second using the ToF-CUP camera.

  6. A silicon photomultiplier readout for time of flight neutron spectroscopy with gamma-ray detectors.

    PubMed

    Pietropaolo, A; Gorini, G; Festa, G; Andreani, C; De Pascale, M P; Reali, E; Grazzi, F; Schooneveld, E M

    2009-09-01

    The silicon photomultiplier (SiPM) is a recently developed photosensor used in particle physics, e.g., for detection of minimum ionizing particles and/or Cherenkov radiation. Its performance is comparable to that of photomultiplier tubes, but with advantages in terms of reduced volume and magnetic field insensitivity. In the present study, the performance of a gamma ray detector made of an yttrium aluminum perovskite scintillation crystal and a SiPM-based readout is assessed for use in time of flight neutron spectroscopy. Measurements performed at the ISIS pulsed neutron source demonstrate the feasibility of gamma-detection based on the new device.

  7. Calibration of time of flight detectors using laser-driven neutron source

    NASA Astrophysics Data System (ADS)

    Mirfayzi, S. R.; Kar, S.; Ahmed, H.; Krygier, A. G.; Green, A.; Alejo, A.; Clarke, R.; Freeman, R. R.; Fuchs, J.; Jung, D.; Kleinschmidt, A.; Morrison, J. T.; Najmudin, Z.; Nakamura, H.; Norreys, P.; Oliver, M.; Roth, M.; Vassura, L.; Zepf, M.; Borghesi, M.

    2015-07-01

    Calibration of three scintillators (EJ232Q, BC422Q, and EJ410) in a time-of-flight arrangement using a laser drive-neutron source is presented. The three plastic scintillator detectors were calibrated with gamma insensitive bubble detector spectrometers, which were absolutely calibrated over a wide range of neutron energies ranging from sub-MeV to 20 MeV. A typical set of data obtained simultaneously by the detectors is shown, measuring the neutron spectrum emitted from a petawatt laser irradiated thin foil.

  8. Waveform-Sampling Electronics for a Whole-Body Time-of-Flight PET Scanner

    PubMed Central

    Ashmanskas, W. J.; LeGeyt, B. C.; Newcomer, F. M.; Panetta, J. V.; Ryan, W. A.; Van Berg, R.; Wiener, R. I.; Karp Fellow, J. S.

    2014-01-01

    Waveform sampling is an appealing technique for instruments requiring precision time and pulse-height measurements. Sampling each PMT waveform at oscilloscope-like rates of several gigasamples per second enables one to process PMT signals digitally, which in turn makes it straightforward to optimize timing resolution and amplitude (energy and position) resolution in response to calibration effects, pile-up effects, and other systematic sources of waveform variation. We describe a system design and preliminary implementation that neatly maps waveform-sampling technology onto the LaPET prototype whole-body time-of-flight PET scanner that serves as the platform for testing this new technology. PMID:25484379

  9. Biomark/Organic Analysis with Time-of-Flight Mass Spectrometry

    NASA Technical Reports Server (NTRS)

    Waite, J. Hunter, Jr.

    2004-01-01

    The concept of a Comprehensive 2-Dimensional Gas Chromatography coupled with Time-of-Flight Mass Spectrometry (GCxGC-TOWS) for the analysis of organic compounds has been proven with commercially available instrumentation (LECO Corp). The performance of a GCxGC instrument has been characterized in various stages using two independent breadboard systems. The GCxGC separation systems, including the thermal modulator, have been miniaturized to the size of a benchtop configuration. One breadboard system employs a Flame Ionization Detector (FID), whereas the second breadboard system employs a Time-of-Fight mass spectrometer (TOFWS) as a detection system.

  10. Interaction of solar wind ions with thin carbon foils: Calibration of time-of-flight spectrometers

    NASA Astrophysics Data System (ADS)

    Gonin, M.; Buergi, Alfred; Oetliker, M.; Bochsler, P.

    1992-11-01

    With the KAFKA (German acronym for carbon foils collisions analyzer) experiment, charge exchange, energy loss and angular scattering of solar wind ions in thin (1 to 10 microg/sq cm) carbon foils, are studied. Such foils are extensively used in time of flight mass spectrometry. So far, the properties of H, He, B, C, N, O, F, Ne, Na, Mg, Al, Si, S, Cl, Ar, K, Ti, Fe, and Ni and in the 0.5 to 5 keV/u energy range have been investigated.

  11. Time-of-flight detection of ultra-cold atoms using resonant frequency modulation imaging.

    PubMed

    Hardman, K S; Wigley, P B; Everitt, P J; Manju, P; Kuhn, C C N; Robins, N P

    2016-06-01

    Resonant frequency modulation imaging is used to detect free falling ultra-cold atoms. A theoretical comparison of fluorescence imaging (FI) and frequency modulation imaging (FMI) is made, indicating that for low optical depth clouds, FMI accomplished a higher signal-to-noise ratio under conditions necessary for a 200 μm spatially resolved atom interferometer. A 750 ms time-of-flight measurement reveals near atom shot-noise limited number measurements of 2×106 Bose-condensed Rb87 atoms. The detection system is applied to high precision spinor BEC based atom interferometer.

  12. Delayed extraction time-of-flight mass spectrometer with electron impact for PAH studies

    NASA Astrophysics Data System (ADS)

    Najeeb, P. K.; Kadhane, U.

    2017-03-01

    A time-of-flight (ToF) mass spectrometer with a pulsed electron beam as well as pulsed extraction of the recoil ions, with variable delay is reported. The effectiveness of this technique is highlighted by studying the statistical decay of mono-cations over microsecond time scales. Various details of the design and operation are discussed in the context of electron impact ionization and fragmentation of naphthalene (C10H8). The temporal behavior of acetylene (C2H2) and diacetylene (C4H2) loss is observed and compared with the associated Arrhenius decay constant, internal energy and plasmon excitation energy.

  13. A high performance Time-of-Flight detector applied to isochronous mass measurement at CSRe

    NASA Astrophysics Data System (ADS)

    Mei, Bo; Tu, Xiaolin; Wang, Meng; Xu, Hushan; Mao, Ruishi; Hu, Zhengguo; Ma, Xinwen; Yuan, Youjin; Zhang, Xueying; Geng, Peng; Shuai, Peng; Zang, Yongdong; Tang, Shuwen; Ma, Peng; Lu, Wan; Yan, Xinshuai; Xia, Jiawen; Xiao, Guoqing; Guo, Zhongyan; Zhang, Hongbin; Yue, Ke

    2010-12-01

    A high performance Time-of-Flight detector has been designed and constructed for isochronous mass spectrometry at the experimental Cooler Storage Ring (CSRe). The detector has been successfully used in an experiment to measure the masses of the N≈ Z≈33 nuclides near the proton drip-line. Of particular interest is the mass of 65As. A maximum detection efficiency of 70% and a time resolution of 118±8 ps (FWHM) have been achieved in the experiment. The dependence of detection efficiency and signal average pulse height (APH) on atomic number Z has been studied. The potential of APH for Z identification has been discussed.

  14. Time-of-Flight Polarized Neutron Reflectometry on PLATYPUS: Status and Future Developments

    NASA Astrophysics Data System (ADS)

    Saerbeck, T.; Cortie, D. L.; Brück, S.; Bertinshaw, J.; Holt, S. A.; Nelson, A.; James, M.; Lee, W. T.; Klose, F.

    Time-of-flight (ToF) polarized neutron reflectometry enables the detailed investigation of depth-resolved magnetic structures in thin film and multilayer magnetic systems. The general advantage of the time-of-flight mode of operation over monochromatic instruments is a decoupling of spectral shape and polarization of the neutron beam with variable resolution. Thus, a wide Q-range can be investigated using a single angle of incidence, with resolution and flux well-adjusted to the experimental requirement. Our paper reviews the current status of the polarization equipment of the ToF reflectometer PLATYPUS and presents first results obtained on stratified Ni80Fe20/α-Fe2O3 films, revealing the distribution of magnetic moments in an exchange bias system. An outlook on the future development of the PLATYPUS polarization system towards the implementation of a polarized 3He cell is presented and discussed with respect to the efficiency and high Q-coverage up to 1 Å-1 and 0.15 Å-1 in the vertical and lateral momentum transfer, respectively.

  15. The multipurpose time-of-flight neutron reflectometer “Platypus” at Australia's OPAL reactor

    NASA Astrophysics Data System (ADS)

    James, M.; Nelson, A.; Holt, S. A.; Saerbeck, T.; Hamilton, W. A.; Klose, F.

    2011-03-01

    In this manuscript we describe the major components of the Platypus time-of-flight neutron reflectometer at the 20 MW OPAL reactor in Sydney, Australia. Platypus is a multipurpose spectrometer for the characterisation of solid thin films, materials adsorbed at the solid-liquid interface and free-liquid surfaces. It also has the capacity to study magnetic thin films using spin-polarised neutrons. Platypus utilises a white neutron beam ( λ=2-20 Å) that is pulsed using boron-coated disc chopper pairs; thus providing the capacity to tailor the wavelength resolution of the pulses to suit the system under investigation. Supermirror optical components are used to focus, deflect or spin-polarise the broad bandwidth neutron beams, and typical incident spectra are presented for each configuration. A series of neutron reflectivity datasets are presented, indicating the quality and flexibility of this spectrometer. Minimum reflectivity values of <10 -7 are observed; while maximum thickness values of 325 nm have been measured for single-component films and 483 nm for a multilayer system. Off-specular measurements have also been made to investigate in-plane features as opposed to those normal to the sample surface. Finally, the first published studies conducted using the Platypus time-of-flight neutron reflectometer are presented.

  16. Slow light and chromatic temporal dispersion in photonic crystal waveguides using femtosecond time of flight.

    PubMed

    Finlayson, C E; Cattaneo, F; Perney, N M B; Baumberg, J J; Netti, M C; Zoorob, M E; Charlton, M D B; Parker, G J

    2006-01-01

    We report time-of-flight experiments on photonic-crystal waveguide structures using optical Kerr gating of a femtosecond white-light supercontinuum. These photonic-crystal structures, based on engineered silicon-nitride slab waveguides, possess broadband low-loss guiding properties, allowing the group velocity dispersion of optical pulses to be directly tracked as a function of wavelength. This dispersion is shown to be radically disrupted by the spectral band gaps associated with the photonic-crystal periodicity. Increased time-of-flight effects, or "slowed light," are clearly observed at the edges of band gaps in agreement with two-dimensional plane-wave theoretical models of group velocity dispersion. A universal model for slow light in such photonic crystals is proposed, which shows that slow light is controlled predominantly by the detuning from, and the size of, the photonic band gaps. Slowed light observed up to time delays of approximately 1 ps, corresponds to anomalous dispersion of approximately 3.5 ps/nm per mm of the photonic crystal structure. From the decreasing intensity of time-gated slow light as a function of time delay, we estimate the characteristic losses of modes which are guided in the spectral proximity of the photonic band gaps.

  17. Determination of Imazaquin and its metabolite by liquid chromatography-quadrupole-time of flight tandem mass.

    PubMed

    Yao, H B; Han, G J; Liu, G X; Xie, Y; Wang, C H

    2010-08-01

    A method consisting of solvent extraction followed by liquid chromatography-quadrupole-time of flight- tandem mass spectrometry analysis was developed for the identification of Imazaquin and its metabolite. The relationships between detector response and sample concentrations showed a high degree of linearity (r > 0.998) over the range 0.03-10 microg/g. The recoveries obtained were in the acceptable range of 86%-104% between spiked. The relative standard deviation of this method was 6.4%-17.1%. A 35-day study of Imazaquin degradation was taken in agricultural soil from Binzhou, China. The degradation followed first order kinetics (C = 0.7672e(-0.0774t)), with half-life of less than 8.5 days. Investigation of the by-products from liquid chromatography-quadrupole-time of flight- tandem mass spectrometry has shown that there were four important metabolites 4-methylene-2-(quinolin-2-yl)-1H-imidazol-5(4H)-one, quinoline-3-carbaldehyde, 1-amino-2,3-dimethyl-1-oxobutan-2-ylium and 1H-[1,2]oxazino[4,5-b]quinolin-1-one in the degradation process. The accurate mass measurements error was 5 ppm in this study. The method was successfully applied to the analysis of imazaquin and its metabolite residues in soil.

  18. TOFPET 2: A high-performance circuit for PET time-of-flight

    NASA Astrophysics Data System (ADS)

    Di Francesco, Agostino; Bugalho, Ricardo; Oliveira, Luis; Rivetti, Angelo; Rolo, Manuel; Silva, Jose C.; Varela, Joao

    2016-07-01

    We present a readout and digitization ASIC featuring low-noise and low-power for time-of flight (TOF) applications using SiPMs. The circuit is designed in standard CMOS 110 nm technology, has 64 independent channels and is optimized for time-of-flight measurement in Positron Emission Tomography (TOF-PET). The input amplifier is a low impedance current conveyor based on a regulated common-gate topology. Each channel has quad-buffered analogue interpolation TDCs (time binning 20 ps) and charge integration ADCs with linear response at full scale (1500 pC). The signal amplitude can also be derived from the measurement of time-over-threshold (ToT). Simulation results show that for a single photo-electron signal with charge 200 (550) fC generated by a SiPM with (320 pF) capacitance the circuit has 24 (30) dB SNR, 75 (39) ps r.m.s. resolution, and 4 (8) mW power consumption. The event rate is 600 kHz per channel, with up to 2 MHz dark counts rejection.

  19. Time-of-flight Extreme Environment Diffractometer at the Helmholtz-Zentrum Berlin.

    PubMed

    Prokhnenko, Oleksandr; Stein, Wolf-Dieter; Bleif, Hans-Jürgen; Fromme, Michael; Bartkowiak, Maciej; Wilpert, Thomas

    2015-03-01

    The Extreme Environment Diffractometer (EXED) is a new neutron time-of-flight instrument at the BER II research reactor at the Helmholtz-Zentrum Berlin, Germany. Although EXED is a special-purpose instrument, its early construction made it available for users as a general-purpose diffractometer. In this respect, EXED became one of the rare examples, where the performance of a time-of-flight diffractometer at a continuous source can be characterized. In this paper, we report on the design and performance of EXED with an emphasis on the unique instrument capabilities. The latter comprise variable wavelength resolution and wavelength band, control of the incoming beam divergence, the possibility to change the angular positions of detectors and their distance to the sample, and use of event recording and offline histogramming. These features combined make EXED easily tunable to the requirements of a particular problem, from conventional diffraction to small angle neutron scattering. The instrument performance is demonstrated by several reference measurements and user experiments.

  20. TOF plotter—a program to perform routine analysis time-of-flight mass spectral data

    NASA Astrophysics Data System (ADS)

    Knippel, Brad C.; Padgett, Clifford W.; Marcus, R. Kenneth

    2004-03-01

    The main article discusses the operation and application of the program to mass spectral data files. This laboratory has recently reported the construction and characterization of a linear time-of-flight mass spectrometer (ToF-MS) utilizing a radio frequency glow discharge ionization source. Data acquisition and analysis was performed using a digital oscilloscope and Microsoft Excel, respectively. Presently, no software package is available that is specifically designed for time-of-flight mass spectral analysis that is not instrument dependent. While spreadsheet applications such as Excel offer tremendous utility, they can be cumbersome when repeatedly performing tasks which are too complex or too user intensive for macros to be viable. To address this situation and make data analysis a faster, simpler task, our laboratory has developed a Microsoft Windows-based software program coded in Microsoft Visual Basic. This program enables the user to rapidly perform routine data analysis tasks such as mass calibration, plotting and smoothing on x- y data sets. In addition to a suite of tools for data analysis, a number of calculators are built into the software to simplify routine calculations pertaining to linear ToF-MS. These include mass resolution, ion kinetic energy and single peak identification calculators. A detailed description of the software and its associated functions is presented followed by a characterization of its performance in the analysis of several representative ToF-MS spectra obtained from different GD-ToF-MS systems.

  1. Lanthanum halide scintillators for time-of-flight 3-D pet

    DOEpatents

    Karp, Joel S.; Surti, Suleman

    2008-06-03

    A Lanthanum Halide scintillator (for example LaCl.sub.3 and LaBr.sub.3) with fast decay time and good timing resolution, as well as high light output and good energy resolution, is used in the design of a PET scanner. The PET scanner includes a cavity for accepting a patient and a plurality of PET detector modules arranged in an approximately cylindrical configuration about the cavity. Each PET detector includes a Lanthanum Halide scintillator having a plurality of Lanthanum Halide crystals, a light guide, and a plurality of photomultiplier tubes arranged respectively peripherally around the cavity. The good timing resolution enables a time-of-flight (TOF) PET scanner to be developed that exhibits a reduction in noise propagation during image reconstruction and a gain in the signal-to-noise ratio. Such a PET scanner includes a time stamp circuit that records the time of receipt of gamma rays by respective PET detectors and provides timing data outputs that are provided to a processor that, in turn, calculates time-of-flight (TOF) of gamma rays through a patient in the cavity and uses the TOF of gamma rays in the reconstruction of images of the patient.

  2. Barrel time-of-flight detector for the PANDA experiment at FAIR

    NASA Astrophysics Data System (ADS)

    Gruber, L.; Brunner, S. E.; Marton, J.; Orth, H.; Suzuki, K.

    2016-07-01

    The barrel time-of-flight detector for the PANDA experiment at FAIR is foreseen as a Scintillator Tile (SciTil) Hodoscope based on several thousand small plastic scintillator tiles read-out with directly attached Silicon Photomultipliers (SiPMs). The main tasks of the system are an accurate determination of the time origin of particle tracks to avoid event mixing at high collision rates, relative time-of-flight measurements as well as particle identification in the low momentum regime. The main requirements are the use of a minimum material amount and a time resolution of σ < 100 ps. We have performed extensive optimization studies and prototype tests to prove the feasibility of the SciTil design and finalize the R&D phase. In a 2.7 GeV/c proton beam at Forschungszentrum Jülich a time resolution of about 80 ps has been achieved using SiPMs from KETEK and Hamamatsu with an active area of 3 × 3mm2. Employing the Digital Photon Counter from Philips a time resolution of about 30 ps has been reached.

  3. Identification of rolling circulating tumor cells using photoacoustic time-of-flight method

    NASA Astrophysics Data System (ADS)

    Sarimollaoglu, Mustafa; Nedosekin, Dmitry A.; Galanzha, Ekaterina I.; Zharov, Vladimir P.

    2013-03-01

    Existing optical techniques for in vivo measurement of blood flow velocity are not quite applicable for determination of velocity of individual cells or nanoparticles. A time-of-flight photoacoustic (PA) technique can solve this problem by measuring the transient PA signal width, which is related to the cell velocity passing the laser beam. This technique was demonstrated in vivo using an animal (mouse) model by estimating the velocity of nanoparticles, and red and white blood cells labeled with conjugated gold nanorods (GNRs) in the bloodstream. Here we describe the features and the parameters of novel modifications to the PA time-of-flight method and its new application for real-time monitoring of circulating tumor cells (CTCs), such as B16F10 melanoma. This method provided, for the first time, identification of rolling CTCs in analogy to rolling white blood cells and CTC aggregates. Specifically, monitoring of PA signal widths from CTCs in mouse ear microvessels revealed double maxima in peak-width histograms associated with the fast moving portion of CTCs in central flow and slowly rolling CTCs in analogy to white blood cells. We also developed a two-parameter plot representing PA peak amplitude and peak widths. This method allowed identification of fast-moving individual CTCs, CTC aggregates, and rolling CTCs. The discovery of rolling CTCs in relatively large blood vessels indicates a higher probability of CTC extravasations, further increasing the possibility of metastasis through rolling mechanism in addition to mechanical capturing of CTCs in small vessels.

  4. Evaluating the capability of time-of-flight cameras for accurately imaging a cyclically loaded beam

    NASA Astrophysics Data System (ADS)

    Lahamy, Hervé; Lichti, Derek; El-Badry, Mamdouh; Qi, Xiaojuan; Detchev, Ivan; Steward, Jeremy; Moravvej, Mohammad

    2015-05-01

    Time-of-flight cameras are used for diverse applications ranging from human-machine interfaces and gaming to robotics and earth topography. This paper aims at evaluating the capability of the Mesa Imaging SR4000 and the Microsoft Kinect 2.0 time-of-flight cameras for accurately imaging the top surface of a concrete beam subjected to fatigue loading in laboratory conditions. Whereas previous work has demonstrated the success of such sensors for measuring the response at point locations, the aim here is to measure the entire beam surface in support of the overall objective of evaluating the effectiveness of concrete beam reinforcement with steel fibre reinforced polymer sheets. After applying corrections for lens distortions to the data and differencing images over time to remove systematic errors due to internal scattering, the periodic deflections experienced by the beam have been estimated for the entire top surface of the beam and at witness plates attached. The results have been assessed by comparison with measurements from highly-accurate laser displacement transducers. This study concludes that both the Microsoft Kinect 2.0 and the Mesa Imaging SR4000s are capable of sensing a moving surface with sub-millimeter accuracy once the image distortions have been modeled and removed.

  5. Breath Analysis Using a Time-of-Flight Camera and Pressure Belts.

    PubMed

    Zalud, Ludek; Kotova, Marketa; Kocmanová, Petra; Dobsak, Petr; Kolarova, Jana

    2016-06-01

    The proper way of breathing is important for everyone. Healthy people often do not follow respiration until breathing problems start-during stress or during sport activity in physiological cases. More serious cases are stroke, injury, or surgery of the chest and others. So, learning to breathe correctly and/or breathing diagnosis is considerable for many reasons. Two novel methods of breath analysis suitable for diagnostics and rehabilitation are presented. The first technique utilizes pressure belts fastened to the patient's belly and chest, and the second method relies on a SwissRanger SR-4000 time-of-flight camera. The measurement principles are described together with the advantages and disadvantages of the applied techniques. The SwissRanger camera depth calibration is proposed to facilitate better results during the breath analysis. The methods are tested on a group of students to provide a comparison of their individual performances. As it was demonstrated, presented methods proved to work reliably. The method based on time-of-flight camera seems to be more suitable for diagnosis, while the method based on pressure belts is more suitable for rehabilitation and biofeedback applications.

  6. Structural measurements on several alamethicin peptides by the time-of-flight correlation technique

    NASA Astrophysics Data System (ADS)

    Poppe-Schriemer, N.; Ens, W.; O'Neil, J. D.; Spicer, V.; Standing, K. G.; Westmore, J. B.; Yee, A. A.

    1995-05-01

    Time-of-flight correlation methods have been used to determine the primary structure of the major component in a nonstandard preparation of alamethicins, and to give some sequence information about minor components. The peptide (MW [approximate] 2000 u) is blocked at the N terminus with an acetyl group and has a primary alcohol rather than a carboxyl group at the C terminus, so the usual wet chemical sequencing methods cannot be applied. Upon bombardment with 25 keVI- ions, the peptide, deposited on the surface of a solid target, produces both molecular ions and prompt fragment ions (i.e. ions formed at or very near the surface of the target). After acceleration, these ions may undergo metastable decay as they pass along the flight tube of a reflecting time-of-flight mass spectrometer. Measurement of the correlations between the neutral and charged daughters from these decompositions determines the decay pattern of each ion, which in turn yields definitive information about the sequence of the original peptide. All events are recorded on magnetic tape and analyzed off-line, so a single run on the spectrometer provides information on the decay of every ion produced at the target, i.e. information similar to that obtainable from a complete set of daughter ion scans on a multiple sector or triple quadrupole instrument.

  7. Pharmaceutical metabolite profiling using quadrupole/ion mobility spectrometry/time-of-flight mass spectrometry.

    PubMed

    Chan, Eric C Y; New, Lee Sun; Yap, Chun Wei; Goh, Lin Tang

    2009-02-01

    The use of hybrid quadrupole ion mobility spectrometry time-of-flight mass spectrometry (Q/IMS/TOFMS) in the metabolite profiling of leflunomide (LEF) and acetaminophen (APAP) is presented. The IMS drift times (T(d)) of the drugs and their metabolites were determined in the IMS/TOFMS experiments and correlated with their exact monoisotopic masses and other in silico generated structural properties, such as connolly molecular area (CMA), connolly solvent-excluded volume (CSEV), principal moments of inertia along the X, Y and Z Cartesian coordinates (MI-X, MI-Y and MI-Z), inverse mobility and collision cross-section (CCS). The correlation of T(d) with these parameters is presented and discussed. IMS/TOF tandem mass spectrometry experiments (MS(2) and MS(3)) were successfully performed on the N-acetyl-p-benzoquinoneimine glutathione (NAPQI-GSH) adduct derived from the in vitro microsomal metabolism of APAP. As comparison, similar experiments were also performed using hybrid triple quadrupole linear ion trap mass spectrometry (QTRAPMS) and quadrupole time-of-flight mass spectrometry (QTOFMS). The abilities to resolve the product ions of the metabolite within the drift tube and fragment the ion mobility resolved product ions in the transfer travelling wave-enabled stacked ring ion guide (TWIG) demonstrated the potential applicability of the Q/IMS/TOFMS technique in pharmaceutical metabolite profiling.

  8. Tagging of Isobars Using Energy Loss and Time-of-flight Measurements

    SciTech Connect

    Shapira, D.

    2001-11-02

    The technique for tagging isobars in a mixed beam by measuring energy loss by time-of-flight has been tested. With this method, isobar separation should improve by allowing more energy loss (thicker absorber), but only if one can control absorber homogeneity. Measurements of beam energy toss and energy spread obtained under such conditions were shown to be close to predicted values using both collisional and charge exchange contributions to energy straggling. The calculation of energy straggling allows us to study the efficacy of this method for isobar separation when applied to different mass ranges and beam energies. Separation in a most difficult case, an analyzed beam of A = 132 isobars at energies near 3 MeV/A has been demonstrated. The time-of-flight information can be added on line as an additional tag to the data stream for events of interest. Such event by event tagging enables one to study the effect of differences in isobaric mixture in the beam on the reaction outcome even when isobar separation is not complete.

  9. Electric field measurement in the ionosphere using the time-of-flight technique

    SciTech Connect

    Nakamura, Masato; Hayakawa, Hajime; Tsuruda, Koichiro )

    1989-05-01

    The first successful electric field measurement in the ionosphere using the time-of-flight technique with a lithium ion beam was carried out on a S-520 sounding rocket launched from Kagoshima Space Center, Japan on January 15, 1987. The purpose of this experiment was to prove the validity of the time-of-flight technique when it is applied to the measurement of the dc electric field in the ionosphere. A time-coded ion beam was ejected from the rocket in the direction perpendicular to the Earth's magnetic field. The beam returned to the rocket twice per rocket spin when the initial beam direction was nearly perpendicular to the electric field. The electric field and the magnetic field were derived from the travel time of these return lithium ions. The accuracy of the electric field determination was {plus minus} 0.3 mV/m. The direction of the electric field was obtained from the direction of the returning ion beam after about one ion gyration. The main constituent of the measured electric field was a V {times} B field due to the rocket motion across the geomagnetic field. The ambient field was less than 1 mV/m. The magnetic field was measured with an accuracy of {plus minus} 2.7 nT in this experiment.

  10. Recent Advances and Future Advances in Time-of-Flight PET

    PubMed Central

    Moses, William W.

    2007-01-01

    Simple theory predicts that the statistical noise variance in PET can be reduced by an order of magnitude by using time-of-flight (TOF) information. This reduction can be obtained by improving the coincidence timing resolution, and so would be achievable in clinical, whole body studies using with PET systems that differ little from existing cameras. The potential impact of this development is large, especially for oncology studies in large patients, where it is sorely needed. TOF PET was extensively studied in the 1980’s but died away in the 1990’s, as it was impossible to reliably achieve sufficient timing resolution without sacrificing other important PET performance aspects, such as spatial resolution and efficiency. Recent advances in technology (scintillators, photodetectors, and high speed electronics) have renewed interest in TOF PET, which is experiencing a rebirth. However, there is still much to be done, both in instrumentation development and evaluating the true benefits of TOF in modern clinical PET. This paper looks at what has been accomplished and what needs to be done before time-of-flight PET can reach its full potential. PMID:18836513

  11. Time-of-flight Extreme Environment Diffractometer at the Helmholtz-Zentrum Berlin

    SciTech Connect

    Prokhnenko, Oleksandr Stein, Wolf-Dieter; Bleif, Hans-Jürgen; Fromme, Michael; Bartkowiak, Maciej; Wilpert, Thomas

    2015-03-15

    The Extreme Environment Diffractometer (EXED) is a new neutron time-of-flight instrument at the BER II research reactor at the Helmholtz-Zentrum Berlin, Germany. Although EXED is a special-purpose instrument, its early construction made it available for users as a general-purpose diffractometer. In this respect, EXED became one of the rare examples, where the performance of a time-of-flight diffractometer at a continuous source can be characterized. In this paper, we report on the design and performance of EXED with an emphasis on the unique instrument capabilities. The latter comprise variable wavelength resolution and wavelength band, control of the incoming beam divergence, the possibility to change the angular positions of detectors and their distance to the sample, and use of event recording and offline histogramming. These features combined make EXED easily tunable to the requirements of a particular problem, from conventional diffraction to small angle neutron scattering. The instrument performance is demonstrated by several reference measurements and user experiments.

  12. A constant-momentum/energy-selector time-of-flight mass spectrometer.

    PubMed

    Santacruz, C P; Håkansson, P; Barofsky, D F; Piyadasa, C K G

    2007-01-01

    A matrix assisted laser desorption/ionization time-of-flight mass spectrometer has been built with an ion source that can be operated in either constant-energy or constant-momentum acceleration modes. A decreasing electric field distribution in the ion-accelerating region makes it possible to direct ions onto a space-focal plane in either modes of operation. Ions produced in the constant-momentum mode have velocities and, thus, flight times that are linearly dependent on mass and kinetic energies that are inversely dependent on mass. The linear mass dispersion doubles mass resolving power of ions accelerated with space-focusing conditions in constant-momentum mode. The mass-dependent kinetic energy is exploited to disperse ions according to mass in a simple kinetic energy filter constructed from two closely spaced, oblique ion reflectors. Focusing velocity of ions of the same mass can substantially improve ion selection for subsequent post source decay or tandem time-of-flight analyses.

  13. The CDFII time-of-flight detector and impact on beauty flavor tagging

    SciTech Connect

    C. Grozis et al.

    2002-12-03

    Following the successful RunI from 1992 to 1996, the CDF detector has undergone a major upgrade [1] for the RunII which begun in March 2001. The approval for the addition of a Time-of-Flight detector was granted in January 1999. The installation of the TOF detector was completed in August 2001 and its data has been included in the CDFII readout since then. The primary physics motivation for TOF is to complement and enhance the particle identification capability provided by the central drift chamber (COT) since it distinguishes K{sup {+-}} and {pi}{sup {+-}} in the momentum region of their cross-over in dE=dX. With an expected time-of-flight resolution of 100 ps, the TOF system will be capable of identifying charged kaons from pions by their flight time difference with at least two standard deviation separation up to kaon momenta of 1.6 GeV/c. Such an addition results in an enhancement of the b flavor identification power, crucial to improve the statistical precision in CP violation and B{sub s} mixing measurements.

  14. Time-frequency energy density precipitation method for time-of-flight extraction of narrowband Lamb wave detection signals.

    PubMed

    Zhang, Y; Huang, S L; Wang, S; Zhao, W

    2016-05-01

    The time-of-flight of the Lamb wave provides an important basis for defect evaluation in metal plates and is the input signal for Lamb wave tomographic imaging. However, the time-of-flight can be difficult to acquire because of the Lamb wave dispersion characteristics. This work proposes a time-frequency energy density precipitation method to accurately extract the time-of-flight of narrowband Lamb wave detection signals in metal plates. In the proposed method, a discrete short-time Fourier transform is performed on the narrowband Lamb wave detection signals to obtain the corresponding discrete time-frequency energy density distribution. The energy density values at the center frequency for all discrete time points are then calculated by linear interpolation. Next, the time-domain energy density curve focused on that center frequency is precipitated by least squares fitting of the calculated energy density values. Finally, the peak times of the energy density curve obtained relative to the initial pulse signal are extracted as the time-of-flight for the narrowband Lamb wave detection signals. An experimental platform is established for time-of-flight extraction of narrowband Lamb wave detection signals, and sensitivity analysis of the proposed time-frequency energy density precipitation method is performed in terms of propagation distance, dispersion characteristics, center frequency, and plate thickness. For comparison, the widely used Hilbert-Huang transform method is also implemented for time-of-flight extraction. The results show that the time-frequency energy density precipitation method can accurately extract the time-of-flight with relative error of <1% and thus can act as a universal time-of-flight extraction method for narrowband Lamb wave detection signals.

  15. Time-frequency energy density precipitation method for time-of-flight extraction of narrowband Lamb wave detection signals

    NASA Astrophysics Data System (ADS)

    Zhang, Y.; Huang, S. L.; Wang, S.; Zhao, W.

    2016-05-01

    The time-of-flight of the Lamb wave provides an important basis for defect evaluation in metal plates and is the input signal for Lamb wave tomographic imaging. However, the time-of-flight can be difficult to acquire because of the Lamb wave dispersion characteristics. This work proposes a time-frequency energy density precipitation method to accurately extract the time-of-flight of narrowband Lamb wave detection signals in metal plates. In the proposed method, a discrete short-time Fourier transform is performed on the narrowband Lamb wave detection signals to obtain the corresponding discrete time-frequency energy density distribution. The energy density values at the center frequency for all discrete time points are then calculated by linear interpolation. Next, the time-domain energy density curve focused on that center frequency is precipitated by least squares fitting of the calculated energy density values. Finally, the peak times of the energy density curve obtained relative to the initial pulse signal are extracted as the time-of-flight for the narrowband Lamb wave detection signals. An experimental platform is established for time-of-flight extraction of narrowband Lamb wave detection signals, and sensitivity analysis of the proposed time-frequency energy density precipitation method is performed in terms of propagation distance, dispersion characteristics, center frequency, and plate thickness. For comparison, the widely used Hilbert-Huang transform method is also implemented for time-of-flight extraction. The results show that the time-frequency energy density precipitation method can accurately extract the time-of-flight with relative error of <1% and thus can act as a universal time-of-flight extraction method for narrowband Lamb wave detection signals.

  16. Development of an ion time-of-flight spectrometer for neutron depth profiling

    NASA Astrophysics Data System (ADS)

    Cetiner, Mustafa Sacit

    Ion time-of-flight spectrometry techniques are investigated for applicability to neutron depth profiling. Time-of-flight techniques are used extensively in a wide range of scientific and technological applications including energy and mass spectroscopy. Neutron depth profiling is a near-surface analysis technique that gives concentration distribution versus depth for certain technologically important light elements. The technique uses thermal or sub-thermal neutrons to initiate (n, p) or (n, alpha) reactions. Concentration versus depth distribution is obtained by the transformation of the energy spectrum into depth distribution by using stopping force tables of the projectiles in the substrate, and by converting the number of counts into concentration using a standard sample of known dose value. Conventionally, neutron depth profiling measurements are based on charged particle spectrometry, which employs semiconductor detectors such as a surface barrier detector (SBD) and the associated electronics. Measurements with semiconductor detectors are affected by a number of broadening mechanisms, which result from the interactions between the projectile ion and the detector material as well as fluctuations in the signal generation process. These are inherent features of the detection mechanism that involve the semiconductor detectors and cannot be avoided. Ion time-of-flight spectrometry offers highly precise measurement capabilities, particularly for slow particles. For high-energy low-mass particles, measurement resolution tends to degrade with all other parameters fixed. The threshold for more precise ion energy measurements with respect to conventional techniques, such as direct energy measurement by a surface barrier detector, is directly related to the design and operating parameters of the device. Time-of-flight spectrometry involves correlated detection of two signals by a coincidence unit. In ion time-of-flight spectroscopy, the ion generates the primary input

  17. Toward Respiratory Assessment Using Depth Measurements from a Time-of-Flight Sensor

    PubMed Central

    Sharp, Charles; Soleimani, Vahid; Hannuna, Sion; Camplani, Massimo; Damen, Dima; Viner, Jason; Mirmehdi, Majid; Dodd, James W.

    2017-01-01

    Introduction: There is increasing interest in technologies that may enable remote monitoring of respiratory disease. Traditional methods for assessing respiratory function such as spirometry can be expensive and require specialist training to perform and interpret. Remote, non-contact tracking of chest wall movement has been explored in the past using structured light, accelerometers and impedance pneumography, but these have often been costly and clinical utility remains to be defined. We present data from a 3-Dimensional time-of-flight camera (found in gaming consoles) used to estimate chest volume during routine spirometry maneuvres. Methods: Patients were recruited from a general respiratory physiology laboratory. Spirometry was performed according to international standards using an unmodified spirometer. A Microsoft Kinect V2 time-of-flight depth sensor was used to reconstruct 3-dimensional models of the subject's thorax to estimate volume-time and flow-time curves following the introduction of a scaling factor to transform measurements to volume estimates. The Bland-Altman method was used to assess agreement of model estimation with simultaneous recordings from the spirometer. Patient characteristics were used to assess predictors of error using regression analysis and to further explore the scaling factors. Results: The chest volume change estimated by the Kinect camera during spirometry tracked respiratory rate accurately and estimated forced vital capacity (FVC) and vital capacity to within ± <1%. Forced expiratory volume estimation did not demonstrate acceptable limits of agreement, with 61.9% of readings showing >150 ml difference. Linear regression including age, gender, height, weight, and pack years of smoking explained 37.0% of the variance in the scaling factor for volume estimation. This technique had a positive predictive value of 0.833 to detect obstructive spirometry. Conclusion: These data illustrate the potential of 3D time-of-flight cameras

  18. Development of grazing incidence devices for space-borne time of flight mass spectrometry

    NASA Astrophysics Data System (ADS)

    Cadu, A.; Devoto, P.; Louarn, P.; Sauvaud, J.-A.

    2012-04-01

    Time of flight mass spectrometer is widely used to study space plasmas in planetary and solar missions. This space-borne instrument selects ions in function of their energy through an electrostatic analyzer. Particles are then post-accelerated to energies in the range of 20 keV to cross a carbon foil. At the foil exit, electrons are emitted and separated from ion beam in the time of flight section. A first detector (a Micro-Channel Plate or MCP) emits a start signal at electron arrival and a second one emits a stop signal at incident ion end of path. The time difference gives the speed of the particle and its mass can be calculated, knowing its initial energy. However, current instruments suffer from strong limitations. The post acceleration needs very high voltage power supplies which are heavy, have a high power consumption and imply technical constraints for the development. A typical instrument weighs from 5 to 6 kg, includes a 20 kV power supply, consumes a least 5 W and encounters corona effect and electrical breakdown problems. Moreover, despite the particle high energy range, scattering and straggling phenomena in the carbon foil significantly reduce the instrument overall resolution. Some methods, such as electrostatic focus lenses or reflectrons, really improve mass separation but global system efficiency remains very low because of the charge state dependence of such devices. The main purpose of our work is to replace carbon foil by grazing incidence MCP's - also known as MPO's, for Micro Pore Optics - for electron emission. Thus, incident particles would back-scatter onto the channel inner surface with an angle of a few degrees. With this solution, we can decrease dispersion sources and lower the power supplies to post accelerate ions. The result would be a lighter and simpler instrument with a substantial resolution improvement. We have first simulated MPO's behavior with TRIM and MARLOWE Monte-Carlo codes. Energy scattering and output angle computed

  19. Toward Respiratory Assessment Using Depth Measurements from a Time-of-Flight Sensor.

    PubMed

    Sharp, Charles; Soleimani, Vahid; Hannuna, Sion; Camplani, Massimo; Damen, Dima; Viner, Jason; Mirmehdi, Majid; Dodd, James W

    2017-01-01

    Introduction: There is increasing interest in technologies that may enable remote monitoring of respiratory disease. Traditional methods for assessing respiratory function such as spirometry can be expensive and require specialist training to perform and interpret. Remote, non-contact tracking of chest wall movement has been explored in the past using structured light, accelerometers and impedance pneumography, but these have often been costly and clinical utility remains to be defined. We present data from a 3-Dimensional time-of-flight camera (found in gaming consoles) used to estimate chest volume during routine spirometry maneuvres. Methods: Patients were recruited from a general respiratory physiology laboratory. Spirometry was performed according to international standards using an unmodified spirometer. A Microsoft Kinect V2 time-of-flight depth sensor was used to reconstruct 3-dimensional models of the subject's thorax to estimate volume-time and flow-time curves following the introduction of a scaling factor to transform measurements to volume estimates. The Bland-Altman method was used to assess agreement of model estimation with simultaneous recordings from the spirometer. Patient characteristics were used to assess predictors of error using regression analysis and to further explore the scaling factors. Results: The chest volume change estimated by the Kinect camera during spirometry tracked respiratory rate accurately and estimated forced vital capacity (FVC) and vital capacity to within ± <1%. Forced expiratory volume estimation did not demonstrate acceptable limits of agreement, with 61.9% of readings showing >150 ml difference. Linear regression including age, gender, height, weight, and pack years of smoking explained 37.0% of the variance in the scaling factor for volume estimation. This technique had a positive predictive value of 0.833 to detect obstructive spirometry. Conclusion: These data illustrate the potential of 3D time-of-flight cameras

  20. Time-of-flight mobility and trapping results for ZnSe.

    NASA Technical Reports Server (NTRS)

    Heaton, J. L., III; Hammond, G. H.; Goldner, R. B.

    1972-01-01

    Results of measurements of time-of-flight mobility and trapping for zinc selenide. The data were obtained at room temperature for electric fields in the range from 30,000 to 800,000 V/cm. A relatively constant hole mobility (about 50 sq cm/V sec) was found for the entire range of investigated fields. The electron mobility was approximately constant (about 400 sq cm/V sec) up to approximately equal to 300,000 V/cm, above which the drift velocity remained constant. No obvious negative differential mobility was observed, even though the Gunn effect has been reported for the field range investigated. Trapping and detrapping times in the vicinity of 1 nsec are reported for both holes and electrons. The field dependence of the electron-trapping times is unusual and remains unexplained.

  1. Campaign 1.7 Pu Aging. Development of Time of Flight Secondary Ion Mass Spectroscopy

    SciTech Connect

    Venhaus, Thomas J.

    2015-09-09

    The first application of Time-of-Flight Secondary Ion Mass Spectroscopy (ToF-SIMS) to an aged plutonium surface has resulted in a rich set of surface chemistry data, as well as some unexpected results. FY15 was highlighted by not only the first mapping of hydrogen-containing features within the metal, but also a prove-in series of experiments using the system’s Sieverts Reaction Cell. These experiments involved successfully heating the sample to ~450 oC for nearly 24 hours while the sample was dosed several times with hydrogen, followed by an in situ ToF-SIMS analysis. During this year, the data allowed for better and more consistent identification of the myriad peaks that result from the SIMS sputter process. In collaboration with the AWE (U.K), the system was also fully aligned for sputter depth profiling for future experiments.

  2. Analyzing neutron time-of-flight spectra from the National Ignition Facility using moments

    NASA Astrophysics Data System (ADS)

    Hatarik, R.; Field, J.; Eckart, M.; Grim, G.; Hartouni, E. P.; Moore, A.; Munro, D.; Sayre, D.

    2016-10-01

    The neutron spectrum produced by an indirectly driven implosion at the National Ignition Facility (NIF) provides valuable insight into the performance of the capsule. There are four neutron time-of-flight (nTOF) spectrometers being used at the NIF which can simultaneously measure DD and DT fusion neutrons on NIF shots. The width of theses peaks have been traditionally associated with the temperature of the plasma, recent work shows that it has to be considered a combination of flow and temperature distributions. This leads to a deviation from a pure gaussian shape of a single temperature static plasma and the presence of higher order moments in the neutron spectrum. The current status of the analysis of neutron spectra from the nTOF diagnostics at the NIF will be presented. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  3. High precision electric gate for time-of-flight ion mass spectrometers

    NASA Technical Reports Server (NTRS)

    Sittler, Edward C. (Inventor)

    2011-01-01

    A time-of-flight mass spectrometer having a chamber with electrodes to generate an electric field in the chamber and electric gating for allowing ions with a predetermined mass and velocity into the electric field. The design uses a row of very thin parallel aligned wires that are pulsed in sequence so the ion can pass through the gap of two parallel plates, which are biased to prevent passage of the ion. This design by itself can provide a high mass resolution capability and a very precise start pulse for an ion mass spectrometer. Furthermore, the ion will only pass through the chamber if it is within a wire diameter of the first wire when it is pulsed and has the right speed so it is near all other wires when they are pulsed.

  4. Denoising and Multivariate Analysis of Time-Of-Flight SIMS Images

    SciTech Connect

    Wickes, Bronwyn; Kim, Y.; Castner, David G.

    2003-08-30

    Time-of-flight SIMS (ToF-SIMS) imaging offers a modality for simultaneously visualizing the spatial distribution of different surface species. However, the utility of ToF-SIMS datasets may be limited by their large size, degraded mass resolution and low ion counts per pixel. Through denoising and multivariate image analysis, regions of similar chemistries may be differentiated more readily in ToF-SIMS image data. Three established denoising algorithms down-binning, boxcar and wavelet filtering were applied to ToF-SIMS images of different surface geometries and chemistries. The effect of these filters on the performance of principal component analysis (PCA) was evaluated in terms of the capture of important chemical image features in the principal component score images, the quality of the principal component

  5. Time of flight spectrometer for background-free positron annihilation induced Auger electron spectroscopy.

    PubMed

    Mukherjee, S; Shastry, K; Anto, C V; Joglekar, P V; Nadesalingam, M P; Xie, S; Jiang, N; Weiss, A H

    2016-03-01

    We describe a novel spectrometer designed for positron annihilation induced Auger electron spectroscopy employing a time-of-flight spectrometer. The spectrometer's new configuration enables us to implant monoenergetic positrons with kinetic energies as low as 1.5 eV on the sample while simultaneously allowing for the detection of electrons emitted from the sample surface at kinetic energies ranging from ∼500 eV to 0 eV. The spectrometer's unique characteristics made it possible to perform (a) first experiments demonstrating the direct transition of a positron from an unbound scattering state to a bound surface state and (b) the first experiments demonstrating that Auger electron spectra can be obtained down to 0 eV without the beam induced secondary electron background obscuring the low energy part of the spectra. Data are presented which show alternative means of estimating positron surface state binding energy and background-free Auger spectra.

  6. Invited article: polarization "down under": the polarized time-of-flight neutron reflectometer PLATYPUS.

    PubMed

    Saerbeck, T; Klose, F; Le Brun, A P; Füzi, J; Brule, A; Nelson, A; Holt, S A; James, M

    2012-08-01

    This review presents the implementation and full characterization of the polarization equipment of the time-of-flight neutron reflectometer PLATYPUS at the Australian Nuclear Science and Technology Organisation (ANSTO). The functionality and efficiency of individual components are evaluated and found to maintain a high neutron beam polarization with a maximum of 99.3% through polarizing Fe/Si supermirrors. Neutron spin-flippers with efficiencies of 99.7% give full control over the incident and scattered neutron spin direction over the whole wavelength spectrum available in the instrument. The first scientific experiments illustrate data correction mechanisms for finite polarizations and reveal an extraordinarily high reproducibility for measuring magnetic thin film samples. The setup is now fully commissioned and available for users through the neutron beam proposal system of the Bragg Institute at ANSTO.

  7. National Ignition Facility (NIF) Neutron time-of-flight (nTOF) Measurements

    SciTech Connect

    Lerche, R A; Glebov, V Y; Moran, M J; McNaney, J M; Kilkenny, J D; Eckart, M; Zacharias, R A; Haslam, J J; Clancy, T J; Yeoman, M F; Warwas, D P; Sangster, T C; Stoeckl, C; Knauer, J; Horsfield, C J

    2010-05-13

    The first three of eighteen neutron time-of-flight (nTOF) channels have been installed at the National Ignition Facility (NIF). The role of these detectors includes yield, temperature, and bang time measurements. This article focuses on nTOF data analysis and quality of results obtained for the first set of experiments to use all 192 NIF beams. Targets produced up to 2 x 10{sup 10} 2.45-MeV neutrons for initial testing of the nTOF detectors. Differences in neutron scattering at the OMEGA laser facility where the detectors were calibrated and at NIF result in different response functions at the two facilities. Monte Carlo modeling shows this difference. The nTOF performance on these early experiments indicates the nTOF system with its full complement of detectors should perform well in future measurements of yield, temperature, and bang time.

  8. Porosity detection in ceramic armor tiles via ultrasonic time-of-flight

    SciTech Connect

    Margetan, Frank J.; Richter, Nathaniel; Jensen, Terrence

    2011-06-23

    Some multilayer armor panels contain ceramic tiles as one constituent, and porosity in the tiles can affect armor performance. It is well known that porosity in ceramic materials leads to a decrease in ultrasonic velocity. We report on a feasibility study exploring the use of ultrasonic time-of-flight (TOF) to locate and characterize porous regions in armor tiles. The tiles in question typically have well-controlled thickness, thus simplifying the translation of TOF data into velocity data. By combining UT velocity measurements and X-ray absorption measurements on selected specimens, one can construct a calibration curve relating velocity to porosity. That relationship can then be used to translate typical ultrasonic C-scans of TOF-versus-position into C-scans of porosity-versus-position. This procedure is demonstrated for pulse/echo, focused-transducer inspections of silicon carbide (SiC) ceramic tiles.

  9. Time of flight elastic recoil detection analysis with a position sensitive detector

    SciTech Connect

    Siketic, Zdravko; Radovic, Iva Bogdanovic; Jaksic, Milko; Skukan, Natko

    2010-03-15

    A position sensitive detection system based on the microchannel plate detector has been constructed and installed at the existing time of flight (TOF) spectrometer in order to perform a kinematic correction and improve the surface time/depth resolution of elastic recoil detection analysis (ERDA) system. The position resolution of the detector has been tested for different types of ions and anode voltages. TOF spectra of recoiled O ions from SiO{sub 2} and F from CaF{sub 2} were collected in coincidence with position sensitive detector signal. Kinematic correction of TOF spectra improved surface time/depth resolution by {approx}20% for our system; however even higher improvements could be obtained in larger solid angle TOF-ERDA systems.

  10. Detection of chlorobenzene derivatives using vacuum ultraviolet ionization time-of-flight mass spectrometry.

    PubMed

    Tonokura, Kenichi; Nakamura, Tomohisa; Koshi, Mitsuo

    2003-08-01

    Vacuum ultraviolet single-photon ionization time-of-flight mass spectrometry (VUV-SPI-TOFMS) has been applied for the detection of chlorobenzene, o-dichlorobenzene, and o-chlorophenol as surrogates for polychlorinated dibenzo-p-dioxine/furans (PCDD/F). The photoionization mass spectra of these compounds appear to be fragmentation free in the ionization processes by the VUV-SPI at 10.2 eV (121.6 nm). Quantum chemical calculations support no fragmentation in the photoionization of chlorobenzene derivatives at around 10 eV. The absolute photoionization cross-sections of chlorobenzene, o-dichlorobenzene, and o-chlorophenol were estimated at 10.2 eV. The photoionization cross-section is an important parameter in the detection of chlorobenzene derivatives by the single-photon ionization technique. The detection limit for chlorobenzene is on the order of tenth parts-per-billion volume (ppbv) in the present experimental setup.

  11. Laser time-of-flight measurement based on time-delay estimation and fitting correction

    NASA Astrophysics Data System (ADS)

    Li, Chao; Chen, Qian; Gu, Guohua; Qian, Weixian

    2013-07-01

    We describe a method based on multichannel time-delay estimation with linear fitting correction for laser time-of-flight (TOF) measurement. The laser TOF measurement system is constructed with a laser source, a stop receiver channel, a reference receiver multichannel, an analog to digital converter (ADC) sampling unit, and a digital signal processing unit. Limited by the sampling rate, the precision of laser TOF measurement is restricted no more than the ADC sampling period in conventional methods. As this problem is considered, multichannel correlation time-delay estimation with linear fitting correction is devised. It is shown that the measuring precision is better than 2 ns with multichannel time-delay estimation and not influenced by signal-to-noise ratio. The experimental results demonstrate that the proposed method is effective and stable.

  12. Laser time-of-flight measurement based on multi-channel time delay estimation

    NASA Astrophysics Data System (ADS)

    Li, Chao; Chen, Qian; Gu, Guohua; Man, Tian

    2013-03-01

    In this paper, a novel method based on multichannel time delay estimation with linear fitting correction for laser time-of-flight (TOF) measurement is described. The laser TOF measurement system is constructed with a laser source, a stop receiver channel, a reference receiver multichannel, an ADC sampling unit and a digital signal processing unit. Limited by the sampling rate, the precision of laser TOF measurement is restricted no more than the ADC sampling period in conventional methods. As this problem is considered, multi-channel correlation time delay estimation with linear fitting correction is devised. It is shown that the measuring precision is better than 2ns with multi-channel time delay estimation and not influenced by SNR. The experimental results demonstrate that the proposed method is effective and stable.

  13. Asymmetric band flipping for time-of-flight neutron diffraction data

    SciTech Connect

    Whitfield, Pamela S.; Coelho, Alan A.

    2016-08-24

    Charge flipping with powder diffraction data is known to produce a result more reliably with high-resolution data,i.e.visible reflections at smalldspacings. This data are readily accessible with the neutron time-of-flight technique but the assumption that negative scattering density is nonphysical is no longer valid where elements with negative scattering lengths are present. The concept of band flipping was introduced in the literature, where a negative threshold is used in addition to a positive threshold during the flipping. But, it was not tested with experimental data at the time. Finallly, band flipping has been implemented inTOPAStogether with the band modification of low-density elimination and tested with experimental powder and Laue single-crystal neutron data.

  14. Stopping power measurements with the Time-of-Flight (ToF) technique

    SciTech Connect

    Fontana, Cristiano L.; Chen, Chien-Hung; Crespillo, Miguel L.; Graham, Joseph T.; Xue, Haizhou; Zhang, Yanwen; Weber, William J.

    2015-11-10

    In our review of measurements of the stopping power of ions in matter is presented along with new measurements of the stopping powers of O, Si, Ti, and Au ions in self-supporting thin foils of SiO2, Nb2O5, and Ta2O5. Moreover, a Time-of-Flight system at the Ion Beam Materials Laboratory at the University of Tennessee, Knoxville, was used in transmission geometry in order to reduce experimental uncertainties. Finally, the resulting stopping powers show good precision and accuracy and corroborate previously quoted values in the literature. New stopping data are determined.

  15. A comparison of four direct geometry time-of-flight spectrometers at the Spallation Neutron Source

    SciTech Connect

    Stone, M. B.; Abernathy, D. L.; Ehlers, G.; Garlea, O.; Podlesnyak, A.; Winn, B.; Niedziela, J. L.; DeBeer-Schmitt, L.; Graves-Brook, M.; Granroth, G. E.; Kolesnikov, A. I.

    2014-04-15

    The Spallation Neutron Source at Oak Ridge National Laboratory now hosts four direct geometry time-of-flight chopper spectrometers. These instruments cover a range of wave-vector and energy transfer space with varying degrees of neutron flux and resolution. The regions of reciprocal and energy space available to measure at these instruments are not exclusive and overlap significantly. We present a direct comparison of the capabilities of this instrumentation, conducted by data mining the instrument usage histories, and specific scanning regimes. In addition, one of the common science missions for these instruments is the study of magnetic excitations in condensed matter systems. We have measured the powder averaged spin wave spectra in one particular sample using each of these instruments, and use these data in our comparisons.

  16. Asymmetric band flipping for time-of-flight neutron diffraction data

    DOE PAGES

    Whitfield, Pamela S.; Coelho, Alan A.

    2016-08-24

    Charge flipping with powder diffraction data is known to produce a result more reliably with high-resolution data,i.e.visible reflections at smalldspacings. This data are readily accessible with the neutron time-of-flight technique but the assumption that negative scattering density is nonphysical is no longer valid where elements with negative scattering lengths are present. The concept of band flipping was introduced in the literature, where a negative threshold is used in addition to a positive threshold during the flipping. But, it was not tested with experimental data at the time. Finallly, band flipping has been implemented inTOPAStogether with the band modification of low-densitymore » elimination and tested with experimental powder and Laue single-crystal neutron data.« less

  17. Delayed bunching for multi-reflection time-of-flight mass separation

    SciTech Connect

    Rosenbusch, M.; Marx, G.; Schweikhard, L.; Wienholtz, F.; Chauveau, P.; Delahaye, P.

    2015-06-29

    Many experiments are handicapped when the ion sources do not only deliver the ions of interest but also contaminations, i.e., unwanted ions of similar mass. In the recent years, multi-reflection time-of-flight mass separation has become a promising method to isolate the ions of interest from the contaminants, in particular for measurements with low-energy short-lived nuclides. To further improve the performance of multi-reflection mass separators with respect to the limitations by space-charge effects, the simultaneously trapped ions are spatially widely distributed in the apparatus. Thus, the ions can propagate with reduced Coulomb interactions until, finally, they are bunched by a change in the trapping conditions for high-resolution mass separation. Proof-of-principle measurements are presented.

  18. Invited Article: Polarization ``Down Under'': The polarized time-of-flight neutron reflectometer PLATYPUS

    NASA Astrophysics Data System (ADS)

    Saerbeck, T.; Klose, F.; Le Brun, A. P.; Füzi, J.; Brule, A.; Nelson, A.; Holt, S. A.; James, M.

    2012-08-01

    This review presents the implementation and full characterization of the polarization equipment of the time-of-flight neutron reflectometer PLATYPUS at the Australian Nuclear Science and Technology Organisation (ANSTO). The functionality and efficiency of individual components are evaluated and found to maintain a high neutron beam polarization with a maximum of 99.3% through polarizing Fe/Si supermirrors. Neutron spin-flippers with efficiencies of 99.7% give full control over the incident and scattered neutron spin direction over the whole wavelength spectrum available in the instrument. The first scientific experiments illustrate data correction mechanisms for finite polarizations and reveal an extraordinarily high reproducibility for measuring magnetic thin film samples. The setup is now fully commissioned and available for users through the neutron beam proposal system of the Bragg Institute at ANSTO.

  19. High-resolution reflecting time-of-flight momentum and energy mapping system

    SciTech Connect

    Wang Chao; Kang Yifan; Weaver, Larry; Chang Zenghu

    2009-07-15

    A new system to map electron momentum and energy is proposed. A reflecting electrode is introduced into a time-of-flight (TOF) system whose decelerating electric field sends all the electrons back to a position-sensitive detector close to but behind the source of the electrons. The longer flying distance that results makes it possible to significantly improve the energy-resolved performance, especially in the higher energy region. The dependence of the new TOF system on its characteristic parameters is analyzed, along with its application to attosecond streak cameras. Experimental results verified a relative energy resolution better than 0.2 eV for 22 eV electrons and also revealed the availability of the improved relative energy resolution smaller than 1.0% for electron energy ranging from 30 to 40 eV.

  20. Data acquisition system with pulse height capability for the TOFED time-of-flight neutron spectrometer

    SciTech Connect

    Chen, Z. J.; Peng, X. Y.; Zhang, X.; Du, T. F.; Hu, Z. M.; Cui, Z. Q.; Ge, L. J.; Xie, X. F.; Yuan, X.; Li, X. Q.; Zhang, G. H.; Chen, J. X.; Fan, T. S.; Gorini, G.; Nocente, M.; Tardocchi, M.; Hu, L. Q.; Zhong, G. Q.; Lin, S. Y.; Wan, B. N.

    2014-11-15

    A new time-of-flight neutron spectrometer TOFED has been constructed for installation at Experimental Advanced Superconducting Tokamak. A data acquisition system combining measurements of flight time and energy from the interaction of neutrons with the TOFED scintillators has been developed. The data acquisition system can provide a digitizing resolution better than 1.5% (to be compared with the >10% resolution of the recoil particle energy in the plastic scintillators) and a time resolution <1 ns. At the same time, it is compatible with high count rate event recording, which is an essential feature to investigate phenomena occurring on time scales faster than the slowing down time (≈100 ms) of the beam ions in the plasma. Implications of these results on the TOFED capability to resolve fast ion signatures in the neutron spectrum from EAST plasmas are discussed.

  1. Data acquisition system with pulse height capability for the TOFED time-of-flight neutron spectrometer.

    PubMed

    Chen, Z J; Peng, X Y; Zhang, X; Du, T F; Hu, Z M; Cui, Z Q; Ge, L J; Xie, X F; Yuan, X; Gorini, G; Nocente, M; Tardocchi, M; Hu, L Q; Zhong, G Q; Lin, S Y; Wan, B N; Li, X Q; Zhang, G H; Chen, J X; Fan, T S

    2014-11-01

    A new time-of-flight neutron spectrometer TOFED has been constructed for installation at Experimental Advanced Superconducting Tokamak. A data acquisition system combining measurements of flight time and energy from the interaction of neutrons with the TOFED scintillators has been developed. The data acquisition system can provide a digitizing resolution better than 1.5% (to be compared with the >10% resolution of the recoil particle energy in the plastic scintillators) and a time resolution <1 ns. At the same time, it is compatible with high count rate event recording, which is an essential feature to investigate phenomena occurring on time scales faster than the slowing down time (≈100 ms) of the beam ions in the plasma. Implications of these results on the TOFED capability to resolve fast ion signatures in the neutron spectrum from EAST plasmas are discussed.

  2. Integrated multi-channel receiver for a pulsed time-of-flight laser radar

    NASA Astrophysics Data System (ADS)

    Jiang, Yan; Liu, Ruqing; Zhu, Jingguo

    2015-04-01

    An integrated multi-channel receiver for a pulsed time-of-flight (TOF) laser rangefinder has been designed in this paper. The receiver chip as an important component of the laser radar device has been implemented in a 0.18um CMOS process. It consists of sixteen channels and every channel includes preamplifier, amplifier stages, high-pass filter and a timing discriminator which contains a timing comparator and a noise comparator. Each signal paths is independent of other channels. Based on the simulations, the bandwidth and transimpedance of the amplifier channel are 652MHz, 99dBΩ. Under the simulation condition of TT corner and 27°C, the propagation delay of the discriminator is 2.15ns and the propagation delay dispersion is 223ps. The power consumption during continuous measurement is 810mW, and the operating temperature range of the device is -10~60°C.

  3. Optimization of a multi-ring detector for Ps time of flight measurements

    NASA Astrophysics Data System (ADS)

    Di Noto, L.; Benetti, M.; Mariazzi, S.; Dalla Betta, G.-F.; Brusa, R. S.

    2013-06-01

    We have designed a multi-ring detector (MRD) based on Bismuth Germanate (BGO) crystals, coupled to Silicon PhotoMultipliers (SiPM) for measuring the Ps time of flight (TOF). The set-up geometry was optimized by Monte Carlo simulations to take into account at different Ps velocities: (i) the background noise due to backscattered positrons, (ii) the crosstalk between adjacent detectors, (iii) the lifetime of Ps decay. Three parameters were defined to evaluate the different configurations and a figure of merit was obtained. This allows the choice of the best set up configuration for measuring Ps emitted with a particular energy range, optimizing the signal to noise ratio and keeping the acquisition time acceptable.

  4. A new neutron time-of-flight detector for fuel-areal-density measurements on OMEGA.

    PubMed

    Glebov, V Yu; Forrest, C J; Marshall, K L; Romanofsky, M; Sangster, T C; Shoup, M J; Stoeckl, C

    2014-11-01

    A new neutron time-of-flight (nTOF) detector for fuel-areal-density measurements in cryogenic DT implosions was installed on the OMEGA Laser System. The nTOF detector has a cylindrical thin-wall, stainless-steel, 8-in.-diam, 4-in.-thick cavity filled with an oxygenated liquid xylene scintillator. Four gated photomultiplier tubes (PMTs) with different gains are used to measure primary DT and D2 neutrons, down-scattered neutrons in nT and nD kinematic edge regions, and to study tertiary neutrons in the same detector. The nTOF detector is located 13.4 m from target chamber center in a well-collimated line of sight. The design details of the nTOF detector, PMT optimization, and test results on OMEGA will be presented.

  5. Quantum fluctuations and condensate fraction during time-of-flight expansion

    SciTech Connect

    Fang Shiang; Lee, Ray-Kuang; Wang, Daw-Wei

    2010-09-15

    The quantum fluctuation effects in the time-of-flight (TOF) experiment for a condensate released from an optical-lattice potential is studied within the truncated Wigner approximation. By investigating both the spatial and momentum density distributions, we find that the condensate fraction decreases monotonically in time and hence cannot be measured in the standard TOF image. We then propose a semiquantitative analysis for such dynamical quantum-depletion process. Our study shows a universal algebraic decay of the true condensate fraction, and has a very good agreement with numerical results. We also discuss possible methods to determine the condensate fraction inside the optical lattice, and its implication to the TOF experiments in higher dimensional systems.

  6. Objective Error Criterion for Evaluation of Mapping Accuracy Based on Sensor Time-of-Flight Measurements.

    PubMed

    Barshan, Billur

    2008-12-15

    An objective error criterion is proposed for evaluating the accuracy of maps of unknown environments acquired by making range measurements with different sensing modalities and processing them with different techniques. The criterion can also be used for the assessment of goodness of fit of curves or shapes fitted to map points. A demonstrative example from ultrasonic mapping is given based on experimentally acquired time-of-flight measurements and compared with a very accurate laser map, considered as absolute reference. The results of the proposed criterion are compared with the Hausdorff metric and the median error criterion results. The error criterion is sufficiently general and flexible that it can be applied to discrete point maps acquired with other mapping techniques and sensing modalities as well.

  7. Development of a correction method for the time-of-flight prompt gamma-ray analysis

    NASA Astrophysics Data System (ADS)

    Huang, M.; Toh, Y.; Ebihara, M.; Kimura, A.; Nakamura, S.

    2017-03-01

    A new analytical technique, time-of-flight prompt gamma-ray analysis, has been developed at the Japan Proton Accelerator Research Complex. In order to apply it to accurate elemental analysis, a set of Fe and Au reference samples were measured to examine the several factors which affect the number of detected events. It was found that major contributing factors included attenuations of neutrons and gamma rays in the sample, live-time fraction and signal pile-up correction. A simulation model was built for the estimation of neutron and gamma-ray attenuations. A simple empirical formula was proposed to calculate the signal pile-up correction factor. The whole correction method has proven to be accurate and reliable.

  8. Atom-atom correlations in time-of-flight imaging of ultracold bosons in optical lattices

    SciTech Connect

    Zaleski, T. A.; Kopec, T. K.

    2011-11-15

    We study the spatial correlations of strongly interacting bosons in a ground state, confined in a two-dimensional square and a three-dimensional cubic lattice. Using the combined Bogoliubov method and the quantum rotor approach, we map the Hamiltonian of strongly interacting bosons onto U(1) phase action in order to calculate the atom-atom correlations' decay along the principal axis and a diagonal of the lattice-plane direction as a function of distance. Lower tunneling rates lead to quicker decays of the correlations, whose character becomes exponential. Finally, correlation functions allow us to calculate quantities that are directly bound to experimental outcomes, namely time-of-flight absorption images and resulting visibility. Our results contain all the characteristic features present in experimental data (transition from Mott insulating blob to superfluid peaks, etc.), emphasizing the usability of the proposed approach.

  9. Studies of polyisobutylene using time-of-flight secondary ion mass spectrometry (TOF-SIMS)

    NASA Astrophysics Data System (ADS)

    Xu, Keyang; Proctor, Andrew; Hercules, David M.

    1995-05-01

    A series of polyisobutylenes (PIBs) with average molecular weights from 800 to 4 × 105 were analyzed using time-of-flight secondary ion mass spectrometry (TOF-SIMS). The PIB spectra consist of a sequence of repeating patterns. Four clusters are observed within each pattern. Each cluster corresponds to several species, which are neutral fragments generated from polymer chain scission, cationized by a silver ion. The species formed have various numbers of double bonds and/or rings, and are separated by two mass units. The data indicate that the average molecular weight of PIB affects the ion formation. It changes the relative cluster intensities in a pattern, and also varies the cluster structures. More fragment-ion species can be detected from a high molecular weight polymer, and the unsaturated fragments are predominant. In addition to the large fragments, small fragment ions also provide information about some structurally important features.

  10. New high-resolution electrostatic ion mass analyzer using time of flight

    NASA Technical Reports Server (NTRS)

    Hamilton, D. C.; Gloeckler, G.; Ipavich, F. M.; Lundgren, R. A.; Sheldon, R. B.

    1990-01-01

    The design of a high-resolution ion-mass analyzer is described, which is based on an accurate measurement of the time of flight (TOF) of ions within a region configured to produce a harmonic potential. In this device, the TOF, which is independent of ion energy, is determined from a start pulse from secondary electrons produced when the ion passes through a thin carbon foil at the entrance of the TOF region and at a stop pulse from the ion striking a microchannel plate upon exciting the region. A laboratory prototype instrument called 'VMASS' was built and was tested at the Goddard Space Flight Center electrostatic accelerator, showing a good mass resolution of the instrument. Sensors of the VMASS type will form part of the WIND Solar Wind and Suprathermal Ion experiment, the Soho mission, and the Advanced Composition Explorer.

  11. A design for a high resolution very-low-Q time-of flight diffractometer.

    SciTech Connect

    Hjelm, R. P.

    1998-09-29

    The design of a high resolution view low-Q time of flight diffractometer was motivated by the anticipated need to perform small-angle neutron scattering measurements at far lower momentum transfer and higher precision than currently available at either pulsed or steady state sources. In addition, it was recognized that flexibility in the configuration of the instrument and ease in which data is acquired are important. The design offers two configurations, a high intensity/very low Q geometry employing a focusing mirror and a medium to high Q-precision/low Q configuration using standard pinhole collimation geometry. The quality of the mirror optics is very important to the performance of the high intensity/very low Q configuration. We believe that the necessary technology exists to fabricate the high quality mirror optics required for the instrument.

  12. A comparison of four direct geometry time-of-flight spectrometers at the Spallation Neutron Source.

    PubMed

    Stone, M B; Niedziela, J L; Abernathy, D L; DeBeer-Schmitt, L; Ehlers, G; Garlea, O; Granroth, G E; Graves-Brook, M; Kolesnikov, A I; Podlesnyak, A; Winn, B

    2014-04-01

    The Spallation Neutron Source at Oak Ridge National Laboratory now hosts four direct geometry time-of-flight chopper spectrometers. These instruments cover a range of wave-vector and energy transfer space with varying degrees of neutron flux and resolution. The regions of reciprocal and energy space available to measure at these instruments are not exclusive and overlap significantly. We present a direct comparison of the capabilities of this instrumentation, conducted by data mining the instrument usage histories, and specific scanning regimes. In addition, one of the common science missions for these instruments is the study of magnetic excitations in condensed matter systems. We have measured the powder averaged spin wave spectra in one particular sample using each of these instruments, and use these data in our comparisons.

  13. Particle identification with the ALICE Time-Of-Flight detector at the LHC

    NASA Astrophysics Data System (ADS)

    Alici, A.

    2014-12-01

    High performance Particle Identification system (PID) is a distinguishing characteristic of the ALICE experiment at the CERN Large Hadron Collider (LHC). Charged particles in the intermediate momentum range are identified in ALICE by the Time-Of-Flight (TOF) detector. The TOF exploits the Multi-gap Resistive Plate Chamber (MRPC) technology, capable of an intrinsic time resolution at the level of few tens of ps with an overall efficiency close to 100% and a large operation plateau. The full system is made of 1593 MRPC chambers with a total area of 141 m2, covering the pseudorapidity interval [-0.9,+0.9] and the full azimuthal angle. The ALICE TOF system has shown very stable operation during the first 3 years of collisions at the LHC. In this paper a summary of the system performance as well as main results with data from collisions will be reported.

  14. The MRPC-based ALICE time-of-flight detector: Status andperformance

    NASA Astrophysics Data System (ADS)

    Alici, A.; ALICE Collaboration

    2013-04-01

    The large time-of-flight (TOF) array is one of the main detectors devoted to charged hadron identification in the mid-rapidity region of the ALICE experiment at the LHC. It allows separation among pions, kaons and protons up to a few GeV/c, covering the full azimuthal angle and -0.9<η<0.9. The TOF exploits the innovative MRPC technology capable of an intrinsic time resolution better than 50 ps with an efficiency close to 100% and a large operational plateau; the full array consists of 1593 MRPCs covering a cylindrical surface of 141 m2. The TOF detector has been efficiently taking data since the first pp collisions recorded in ALICE in December 2009. In this report, the status of the TOF detector and the performance achieved for both pp and Pb-Pb collisions aredescribed.

  15. Status and performance of the ALICE MRPC-based Time-Of-Flight detector

    NASA Astrophysics Data System (ADS)

    Alici, A.

    2012-10-01

    ALICE is the dedicated heavy-ion experiment at the CERN LHC. One of the main detectors devoted to charged hadron identification in the ALICE central barrel is a large Time-Of-Flight (TOF) array; it allows separation among pions, kaons and protons up to a few GeV/c, covering the full azimuthal angle and -0.9 < η < 0.9. The very good performance required for such a system has been achieved by means of the Multigap Resistive Plate Chamber (MRPC) whose intrinsic time resolution is better than 50 ps with an overall efficiency close to 100% and a large operational plateau; the full array consists of 1593 MRPCs covering a cylindrical surface of 141 m2. In this report, the status of the TOF detector and the performance achieved during the 2010 and 2011 data taking periods are reported together with selected physics results obtained with pp and Pb-Pb collisions.

  16. A comparison of four direct geometry time-of-flight spectrometers at the Spallation Neutron Source

    SciTech Connect

    Stone, Matthew B; Niedziela, Jennifer L; Abernathy, Douglas L; Debeer-Schmitt, Lisa M; Garlea, Vasile O; Granroth, Garrett E; Graves-Brook, Melissa K; Ehlers, Georg; Kolesnikov, Alexander I; Podlesnyak, Andrey A; Winn, Barry L

    2014-04-01

    The Spallation Neutron Source at Oak Ridge National Laboratory now hosts four direct geometry time-of-flight chopper spectrometers. These instruments cover a range of wave vector and energy transfer space with varying degrees of neutron flux and resolution. The regions of reciprocal and energy space available to measure at these instruments is not exclusive and overlaps significantly. We present a direct comparison of the capabilities of this instrumentation, conducted by data mining the instrument usage histories, and specific scanning regimes. In addition, one of the common science missions for these instruments is the study of magnetic excitations in condensed matter systems. We have measured the powder averaged spin wave spectra in one particular sample using each of these instruments, and use these data in our comparisons.

  17. Quantitative analysis of biomolecules by time-of-flight secondary-ion mass spectrometry: Fundamental considerations

    SciTech Connect

    Muddiman, D.C.; Nicola, A.J.; Proctor, A.

    1995-12-31

    Static Time-of-Flight Secondary-Ion Mass Spectrometry (TOF-SIMS) has been applied to investigate an extensive assortment of analytical systems; from semiconductors to DNA sequencing. Recently, the TOF-SIMS method has been successfully applied to real biological systems. This report focuses on some important aspects that must be taken into consideration when conducting measurements on biomaterials in order to observe the potential the TOF-SIMS method affords. The current data are presented using Cyclosporin A (CsA, 1202 Da) and cocaine (303 Da) as model compounds. CsA is observed in the TOF-SIMS mass spectrum predominately as a Ag-cationized species and cocaine as a protonated species; thus, they are complementary probe molecules.

  18. Encrypted Three-dimensional Dynamic Imaging using Snapshot Time-of-flight Compressed Ultrafast Photography

    PubMed Central

    Liang, Jinyang; Gao, Liang; Hai, Pengfei; Li, Chiye; Wang, Lihong V.

    2015-01-01

    Compressed ultrafast photography (CUP), a computational imaging technique, is synchronized with short-pulsed laser illumination to enable dynamic three-dimensional (3D) imaging. By leveraging the time-of-flight (ToF) information of pulsed light backscattered by the object, ToF-CUP can reconstruct a volumetric image from a single camera snapshot. In addition, the approach unites the encryption of depth data with the compressed acquisition of 3D data in a single snapshot measurement, thereby allowing efficient and secure data storage and transmission. We demonstrated high-speed 3D videography of moving objects at up to 75 volumes per second. The ToF-CUP camera was applied to track the 3D position of a live comet goldfish. We have also imaged a moving object obscured by a scattering medium. PMID:26503834

  19. Joint Temperature-Lasing Mode Compensation for Time-of-Flight LiDAR Sensors

    PubMed Central

    Alhashimi, Anas; Varagnolo, Damiano; Gustafsson, Thomas

    2015-01-01

    We propose an expectation maximization (EM) strategy for improving the precision of time of flight (ToF) light detection and ranging (LiDAR) scanners. The novel algorithm statistically accounts not only for the bias induced by temperature changes in the laser diode, but also for the multi-modality of the measurement noises that is induced by mode-hopping effects. Instrumental to the proposed EM algorithm, we also describe a general thermal dynamics model that can be learned either from just input-output data or from a combination of simple temperature experiments and information from the laser’s datasheet. We test the strategy on a SICK LMS 200 device and improve its average absolute error by a factor of three. PMID:26690445

  20. Development of picoseconds Time of Flight systems in Meson Test Beam Facility at Fermilab

    SciTech Connect

    Ronzhin, A.; Albrow, M.; Demarteau, M.; Los, S.; Malik, S.; Pronko, S.; Ramberg, E.; Zatserklyaniy, A.; /Puerto Rico U., Mayaguez

    2010-11-01

    The goal of the work is to develop time of flight (TOF) system with about 10 picosecond time resolution in real beam line when start and stop counters separated by some distance. We name the distance as 'base' for the TOF. This 'real' TOF setup is different from another one when start and stop counters located next to each other. The real TOF is sensitive to beam momentum spread, beam divergence, etc. Anyway some preliminary measurements are useful with close placement of start and stop counter. We name it 'close geometry'. The work started about 2 years ago at Fermilab Meson Test Beam Facility (MTBF). The devices tested in 'close geometry' were Microchannel Plate Photomultipliers (MCP PMT) with Cherenkov radiators. TOF counters based on Silicon Photomultipliers (SiPms) with Cherenkov radiators also in 'close geometry' were tested. We report here new results obtained with the counters in the MTBF at Fermilab, including beam line data.

  1. A new neutron time-of-flight detector for fuel-areal-density measurements on OMEGA

    SciTech Connect

    Glebov, V. Yu. Forrest, C. J.; Marshall, K. L.; Romanofsky, M.; Sangster, T. C.; Shoup, M. J.; Stoeckl, C.

    2014-11-15

    A new neutron time-of-flight (nTOF) detector for fuel-areal-density measurements in cryogenic DT implosions was installed on the OMEGA Laser System. The nTOF detector has a cylindrical thin-wall, stainless-steel, 8-in.-diam, 4-in.-thick cavity filled with an oxygenated liquid xylene scintillator. Four gated photomultiplier tubes (PMTs) with different gains are used to measure primary DT and D{sub 2} neutrons, down-scattered neutrons in nT and nD kinematic edge regions, and to study tertiary neutrons in the same detector. The nTOF detector is located 13.4 m from target chamber center in a well-collimated line of sight. The design details of the nTOF detector, PMT optimization, and test results on OMEGA will be presented.

  2. Laser Time-of-Flight Mass Spectrometry for Future In Situ Planetary Missions

    NASA Technical Reports Server (NTRS)

    Getty, S. A.; Brinckerhoff, W. B.; Cornish, T.; Ecelberger, S. A.; Li, X.; Floyd, M. A. Merrill; Chanover, N.; Uckert, K.; Voelz, D.; Xiao, X.; Tawalbeh, R.; Glenar, D.; Elsila, J. E.; Callahan, M.

    2012-01-01

    Laser desorption/ionization time-of-flight mass spectrometry (LD-TOF-MS) is a versatile, low-complexity instrument class that holds significant promise for future landed in situ planetary missions that emphasize compositional analysis of surface materials. Here we describe a 5kg-class instrument that is capable of detecting and analyzing a variety of analytes directly from rock or ice samples. Through laboratory studies of a suite of representative samples, we show that detection and analysis of key mineral composition, small organics, and particularly, higher molecular weight organics are well suited to this instrument design. A mass range exceeding 100,000 Da has recently been demonstrated. We describe recent efforts in instrument prototype development and future directions that will enhance our analytical capabilities targeting organic mixtures on primitive and icy bodies. We present results on a series of standards, simulated mixtures, and meteoritic samples.

  3. High precision laser ranging by time-of-flight measurement of femtosecond pulses

    NASA Astrophysics Data System (ADS)

    Lee, Joohyung; Lee, Keunwoo; Lee, Sanghyun; Kim, Seung-Woo; Kim, Young-Jin

    2012-06-01

    Time-of-flight (TOF) measurement of femtosecond light pulses was investigated for laser ranging of long distances with sub-micrometer precision in the air. The bandwidth limitation of the photo-detection electronics used in timing femtosecond pulses was overcome by adopting a type-II nonlinear second-harmonic crystal that permits the production of a balanced optical cross-correlation signal between two overlapping light pulses. This method offered a sub-femtosecond timing resolution in determining the temporal offset between two pulses through lock-in control of the pulse repetition rate with reference to the atomic clock. The exceptional ranging capability was verified by measuring various distances of 1.5, 60 and 700 m. This method is found well suited for future space missions based on formation-flying satellites as well as large-scale industrial applications for land surveying, aircraft manufacturing and shipbuilding.

  4. Laser ranging by time-of-flight measurement of femtosecond light pulses

    NASA Astrophysics Data System (ADS)

    Kim, Young-Jin

    2014-04-01

    Time-of-flight (TOF) measurement of femtosecond light pulses was investigated for laser ranging of long distances with sub-micrometer precision in the air. The bandwidth limitation of the photo-detection electronics used in timing femtosecond pulses was overcome by adopting a type-II nonlinear second-harmonic crystal that permits producing the balanced optical cross-correlation signal between two overlapped light pulses. This method offered a sub-femtosecond timing resolution in determining the temporal offset between two pulses through lock-in control of the pulse repetition rate with reference to the atomic clock. The exceptional ranging capability was verified by measuring various distances from 1.5 m to 700 m. This method is found suited for terrestrial land surveying and space missions of formation-flying satellites.

  5. Recovering three-dimensional shape around a corner using ultrafast time-of-flight imaging

    NASA Astrophysics Data System (ADS)

    Velten, Andreas; Willwacher, Thomas; Gupta, Otkrist; Veeraraghavan, Ashok; Bawendi, Moungi G.; Raskar, Ramesh

    2012-03-01

    The recovery of objects obscured by scattering is an important goal in imaging and has been approached by exploiting, for example, coherence properties, ballistic photons or penetrating wavelengths. Common methods use scattered light transmitted through an occluding material, although these fail if the occluder is opaque. Light is scattered not only by transmission through objects, but also by multiple reflection from diffuse surfaces in a scene. This reflected light contains information about the scene that becomes mixed by the diffuse reflections before reaching the image sensor. This mixing is difficult to decode using traditional cameras. Here we report the combination of a time-of-flight technique and computational reconstruction algorithms to untangle image information mixed by diffuse reflection. We demonstrate a three-dimensional range camera able to look around a corner using diffusely reflected light that achieves sub-millimetre depth precision and centimetre lateral precision over 40 cm×40 cm×40 cm of hidden space.

  6. Encrypted Three-dimensional Dynamic Imaging using Snapshot Time-of-flight Compressed Ultrafast Photography

    NASA Astrophysics Data System (ADS)

    Liang, Jinyang; Gao, Liang; Hai, Pengfei; Li, Chiye; Wang, Lihong V.

    2015-10-01

    Compressed ultrafast photography (CUP), a computational imaging technique, is synchronized with short-pulsed laser illumination to enable dynamic three-dimensional (3D) imaging. By leveraging the time-of-flight (ToF) information of pulsed light backscattered by the object, ToF-CUP can reconstruct a volumetric image from a single camera snapshot. In addition, the approach unites the encryption of depth data with the compressed acquisition of 3D data in a single snapshot measurement, thereby allowing efficient and secure data storage and transmission. We demonstrated high-speed 3D videography of moving objects at up to 75 volumes per second. The ToF-CUP camera was applied to track the 3D position of a live comet goldfish. We have also imaged a moving object obscured by a scattering medium.

  7. MONSTER: a time of flight spectrometer for β-delayed neutron emission measurements

    NASA Astrophysics Data System (ADS)

    Garcia, A. R.; Martínez, T.; Cano-Ott, D.; Castilla, J.; Guerrero, C.; Marín, J.; Martínez, G.; Mendoza, E.; Ovejero, M. C.; Reillo, E. M.; Santos, C.; Tera, F. J.; Villamarín, D.; Nolte, R.; Agramunt, J.; Algora, A.; Tain, J. L.; Banerjee, K.; Bhattacharya, C.; Pentillä, H.; Rinta-Antila, S.; Gorelov, D.

    2012-05-01

    The knowledge of the β-decay properties of nuclei contributes decisively to our understanding of nuclear phenomena: the β-delayed neutron emission of neutron rich nuclei plays an important role in the nucleosynthesis r-process and constitutes a probe for nuclear structure of very neutron rich nuclei providing information about the high energy part of the full beta strength (Sβ) function. In addition, β-delayed neutrons are essential for the control and safety of nuclear reactors. In order to determine the neutron energy spectra and emission probabilities from neutron precursors a MOdular Neutron time-of-flight SpectromeTER (MONSTER) has been proposed for the DESPEC experiment at the future FAIR facility. The design of MONSTER and status of its construction are reported in this work.

  8. Calibration and operation of a neutron time-of-flight scintillator array on nova

    SciTech Connect

    Chrien, R.E.; Klare, K.A.; Murphy, T.J.

    1995-12-31

    The Tion diagnostic is a 1020-channel scintillator array on the Nova laser at Livermore. It measures the arrival time of single d-d or d-t neutrons at 27 m from the target with a time resolution of 4 ns. The effect of neutron scattering has been obtained from Monte-Carlo neutron transport simulations and the scattered response is convolved with a gaussian source to fit the data. The data analysis has been checked using targets which produce roughly equal numbers of d-t and d-d counts. The spectrum from Tion is in reasonable agreement with conventional neutron time-of-flight detectors at yields above 3 x 10{sup 8}.

  9. Automated Gain Control Ion Funnel Trap for Orthogonal Time-of-Flight Mass Spectrometry

    PubMed Central

    Ibrahim, Yehia M.; Belov, Mikhail E.; Liyu, Andrei V.; Smith, Richard D.

    2009-01-01

    Time-of-flight mass spectrometry (TOF MS) is increasingly used in proteomics research. Herein, we report on the development and characterization of a TOF MS instrument with improved sensitivity equipped with an electrodynamic ion funnel trap (IFT) that employs an automated gain control (AGC) capability. The IFT-TOF MS was coupled to a reversed-phase capillary liquid chromatography (RPLC) separation and evaluated in experiments with complex proteolytic digests. When applied to a global tryptic digest of Shewanella oneidensis proteins, an order-of-magnitude increase in sensitivity compared to that of the conventional continuous mode of operation was achieved due to efficient ion accumulation prior to TOF MS analysis. As a result of this sensitivity improvement and related improvement in mass measurement accuracy, the number of unique peptides identified in the AGC-IFT mode was 5-fold greater than that obtained in the continuous mode. PMID:18512944

  10. Standardization of time-of-flight laser ionization mass spectrometry analysis of minerals

    NASA Astrophysics Data System (ADS)

    Dimov, S. S.; Chryssoulis, S. L.

    1998-03-01

    The standardization of the time-of-flight laser ionization mass spectrometry (TOF-LIMS) analysis of mineral surfaces is an important step towards providing reproducible quantitative data. This paper reports the search for experimental conditions and instrumental configurations that provide efficient ionization for all elements of the sample. For that purpose, an investigation of the neutral emission dynamics and the ion yields for the most important elements, as a function of laser power densities, the relative time delay between the ablation and postionization processes, and the sample matrix, was performed. In order to standardize the procedure, an empirical protocol was established, based on the use of optimized system parameters to monitor the ion yield from a library of standard reference samples.

  11. A miniature laser ablation time-of-flight mass spectrometer for in situ planetary exploration

    NASA Astrophysics Data System (ADS)

    Rohner, Urs; Whitby, James A.; Wurz, Peter

    2003-12-01

    We report the development and testing of a miniature mass spectrometer and ion source intended to be deployed on an airless planetary surface to measure the elemental and isotopic composition of rocks and soils. Our design concentrates at this stage on the proposed BepiColombo mission to the planet Mercury. The mass analyser is an axially symmetric reflectron time-of-flight design. The ion source utilizes a laser induced plasma, which is directly coupled into the mass analyser. Laser ablation gives high spatial resolution, and avoids the need for sample preparation. Our prototype instrument has a demonstrated mass resolution m/Dgrm (FWHM) in excess of 600 and a predicted dynamic range of better than four orders of magnitude. Isotopic fractionation effects are found to be minor. We estimate that a flight instrument would have a mass of 500 g (including all electronics), a volume of 650 cm3 and could operate on 3 W power.

  12. Probing nanoparticles and nanoparticle-conjugated biomolecules using time-of-flight secondary ion mass spectrometry.

    PubMed

    Kim, Young-Pil; Shon, Hyun Kyong; Shin, Seung Koo; Lee, Tae Geol

    2015-01-01

    Bio-conjugated nanoparticles have emerged as novel molecular probes in nano-biotechnology and nanomedicine and chemical analyses of their surfaces have become challenges. The time-of-flight (TOF) secondary ion mass spectrometry (SIMS) has been one of the most powerful surface characterization techniques for both nanoparticles and biomolecules. When combined with various nanoparticle-based signal enhancing strategies, TOF-SIMS can probe the functionalization of nanoparticles as well as their locations and interactions in biological systems. Especially, nanoparticle-based SIMS is an attractive approach for label-free drug screening because signal-enhancing nanoparticles can be designed to directly measure the enzyme activity. The chemical-specific imaging analysis using SIMS is also well suited to screen nanoparticles and nanoparticle-biomolecule conjugates in complex environments. This review presents some recent applications of nanoparticle-based TOF-SIMS to the chemical analysis of complex biological systems.

  13. Depth profiling and imaging capabilities of an ultrashort pulse laser ablation time of flight mass spectrometer

    PubMed Central

    Cui, Yang; Moore, Jerry F.; Milasinovic, Slobodan; Liu, Yaoming; Gordon, Robert J.; Hanley, Luke

    2012-01-01

    An ultrafast laser ablation time-of-flight mass spectrometer (AToF-MS) and associated data acquisition software that permits imaging at micron-scale resolution and sub-micron-scale depth profiling are described. The ion funnel-based source of this instrument can be operated at pressures ranging from 10−8 to ∼0.3 mbar. Mass spectra may be collected and stored at a rate of 1 kHz by the data acquisition system, allowing the instrument to be coupled with standard commercial Ti:sapphire lasers. The capabilities of the AToF-MS instrument are demonstrated on metal foils and semiconductor wafers using a Ti:sapphire laser emitting 800 nm, ∼75 fs pulses at 1 kHz. Results show that elemental quantification and depth profiling are feasible with this instrument. PMID:23020378

  14. On the numerical corrections of time-of-flight neutron powder diffraction data.

    SciTech Connect

    Avdeev, M.; Jorgensen, J.; Short, S.; Von Dreele, R.

    2007-08-01

    Time-of-flight neutron powder diffraction data for NIST Standard Reference Materials have been used to study the adequacy of the peak profile model obtained from a convolution of back-to-back exponentials with a pseudo-Voigt function that is widely used in Rietveld refinement. It is shown that, while the empirical models for d-spacing (wavelength) dependence of Gaussian and Lorentzian components of the pseudo-Voigt function and rise exponent are satisfactory, the behavior of the decay exponent and peak positions demonstrate significant deviations, which can be corrected by numerical methods. The practical side of this process as implemented in GSAS and FULLPROF and the effect of the corrections on the Rietveld analysis results are discussed.

  15. A novel principle for an ion mirror design in time-of-flight mass spectrometry

    NASA Astrophysics Data System (ADS)

    Scherer, S.; Altwegg, K.; Balsiger, H.; Fischer, J.; Jäckel, A.; Korth, A.; Mildner, M.; Piazza, D.; Reme, H.; Wurz, P.

    2006-03-01

    A novel design for a gridless two-stage ion mirror, or reflectron, for time-of-flight mass spectrometry (TOFMS) will be presented. The development of this novel design was driven by the stringent engineering requirements for the ion mirror's utilization by the reflectron time-of-flight (RTOF) sensor in the Rosetta orbiter spectrometer for ion and neutral analysis (ROSINA) instrument package of the Rosetta cometary mission launched by the European Space Agency in March 2004. The reflectron consists of ceramic and titanium alloy components joined by brazing and welding processes. The device serves as both the mechanical structure and as an ultra-high-vacuum (UHV) enclosure for the TOFMS system. The electrostatic fields of the reflectron are generated along two individually adjustable sections of a resistor helix applied to the inner surface of a ceramic cylinder. This design allows for increased homogeneity of the electrostatic fields, and minimizes fringe fields close to the cylindrical boundary of the reflectron structure. Thus, the usable inner diameter of ion flight path for a given outer diameter is maximized; a feature required by spacecraft constraints. An additional electrostatic lens in front of the reflectron allows the geometrical alteration of the shape of the ion beam, and its direction with regard to the ion optical axis. This makes it possible to switch the operation of the TOFMS system between a single-reflection and a triple-reflection mode, the latter using an additional ion mirror. Typically, mass resolutions of up to 5000 at full width at half maximum (FWHM) have been achieved in the triple-reflection mode for an overall sensor dimension of 1 m. Experimental results in the single-reflection mode and in the triple-reflection mode will be presented. Environmental constraints for space applications will also be discussed.

  16. Geometry Survey of the Time-of-Flight Neutron-Elastic Scattering (Antonella) Experiment

    SciTech Connect

    Oshinowo, Babatunde O.; Izraelevitch, Federico

    2016-10-17

    The Antonella experiment is a measurement of the ionization efficiency of nuclear recoils in silicon at low energies [1]. It is a neutron elastic scattering experiment motivated by the search for dark matter particles. In this experiment, a proton beam hits a lithium target and neutrons are produced. The neutron shower passes through a collimator that produces a neutron beam. The beam illuminates a silicon detector. With a certain probability, a neutron interacts with a silicon nucleus of the detector producing elastic scattering. After the interaction, a fraction of the neutron energy is transferred to the silicon nucleus which acquires kinetic energy and recoils. This kinetic energy is then dissipated in the detector producing ionization and thermal energy. The ionization produced is measured with the silicon detector electronics. On the other hand, the neutron is scattered out of the beam. A neutron-detector array (made of scintillator bars) registers the neutron arrival time and the scattering angle to reconstruct the kinematics of the neutron-nucleus interaction with the time-of-flight technique [2]. In the reconstruction equations, the energy of the nuclear recoil is a function of the scattering angle with respect to the beam direction, the time-of-flight of the neutron and the geometric distances between components of the setup (neutron-production target, silicon detector, scintillator bars). This paper summarizes the survey of the different components of the experiment that made possible the off-line analysis of the collected data. Measurements were made with the API Radian Laser Tracker and I-360 Probe Wireless. The survey was completed at the University of Notre Dame, Indiana, USA in February 2015.

  17. Status and outlook of the neutron time-of-flight facility n_TOF at CERN

    NASA Astrophysics Data System (ADS)

    Gunsing, F.; Abbondanno, U.; Aerts, G.; Álvarez, H.; Álvarez-Velarde, F.; Andriamonje, S.; Andrzejewski, J.; Assimakopoulos, P.; Audouin, L.; Badurek, G.; Baumann, P.; Bečvář, F.; Berthoumieux, E.; Calviño, F.; Cano-Ott, D.; Capote, R.; de Albornoz, A. Carrillo; Cennini, P.; Chepel, V.; Chiaveri, E.; Colonna, N.; Cortes, G.; Couture, A.; Cox, J.; Dahlfors, M.; David, S.; Dillman, I.; Dolfini, R.; Domingo-Pardo, C.; Dridi, W.; Duran, I.; Eleftheriadis, C.; Ferrant, L.; Ferrari, A.; Ferreira-Marques, R.; Frais-Koelbl, H.; Fujii, K.; Furman, W.; Goncalves, I.; González-Romero, E.; Goverdovski, A.; Gramegna, F.; Griesmayer, E.; Guerrero, C.; Haas, B.; Haight, R.; Heil, M.; Herrera-Martinez, A.; Igashira, M.; Isaev, S.; Jericha, E.; Käppeler, F.; Kadi, Y.; Karadimos, D.; Karamanis, D.; Kerveno, M.; Ketlerov, V.; Koehler, P.; Konovalov, V.; Kossionides, E.; Krtička, M.; Lampoudis, C.; Leeb, H.; Lindote, A.; Lopes, I.; Lozano, M.; Lukic, S.; Marganiec, J.; Marques, L.; Marrone, S.; Martínez, T.; Massimi, C.; Mastinu, P.; Mengoni, A.; Milazzo, P. M.; Moreau, C.; Mosconi, M.; Neves, F.; Oberhummer, H.; O'Brien, S.; Oshima, M.; Pancin, J.; Papachristodoulou, C.; Papadopoulos, C.; Paradela, C.; Patronis, N.; Pavlik, A.; Pavlopoulos, P.; Perrot, L.; Pigni, M. T.; Plag, R.; Plompen, A.; Plukis, A.; Poch, A.; Pretel, C.; Quesada, J.; Rauscher, T.; Reifarth, R.; Rosetti, M.; Rubbia, C.; Rudolf, G.; Rullhusen, P.; Salgado, J.; Sarchiapone, L.; Savvidis, I.; Stephan, C.; Tagliente, G.; Tain, J. L.; Tassan-Got, L.; Tavora, L.; Terlizzi, R.; Vannini, G.; Vaz, P.; Ventura, A.; Villamarin, D.; Vincente, M. C.; Vlachoudis, V.; Vlastou, R.; Voss, F.; Walter, S.; Wendler, H.; Wiescher, M.; Wisshak, K.; n TOF Collaboration

    2007-08-01

    The neutron time-of-flight facility n_TOF at CERN, fully operational since 2002, combines a high instantaneous neutron flux with high energy resolution. The wide energy range and the high neutron flux per time-of-flight burst result in a much enhanced signal to background ratio for neutron capture of radioactive isotopes and makes this facility well suited for the measurement of high quality neutron-induced reaction cross-sections. Neutrons are created by spallation reactions induced by a pulsed 20 GeV/c proton beam impinging on a lead target. A 5 cm water slab surrounding the lead target serves as a coolant and at the same time as a moderator of the spallation neutron spectrum, providing a wide energy spectrum from 0.1 eV to about 250 MeV. By the end of 2005, a first phase of data taking has been successfully terminated. Fission and capture experiments have been performed on a variety of isotopes of interest for nuclear astrophysics, advanced nuclear technologies and for basic nuclear physics. The instrumentation developed for this facility consists of parallel plate avalanche counter and fission ionization chamber detectors for the fission experiments and of low mass C6D6 detectors and a 4 pi BaF2 total absorption calorimeter for capture experiments. A new data acquisition system, based on sampling of the detector signals, has been developed to cope with the high count rates and to minimize the effective dead time to only a few tens of nanosecond. A second phase of data taking is planned to start in 2007, after an upgrade of the spallation target. On the longer term, the construction of a flight path at 20 m resulting in an increased neutron flux of about a factor of 100 opens new possibilities.

  18. C60 SIMS with a Hybrid-Quadrupole Orthogonal time-of-flight Mass Spectrometer

    PubMed Central

    Carado, Anthony; Passarelli, M. K.; Kozole, Joseph; Wingate, J. E.; Winograd, Nicholas; Loboda, A. V.

    2009-01-01

    A hybrid quadrupole orthogonal time-of-flight mass spectrometer optimized for MALDI and electrospray ionization has been equipped with a C60 cluster ion source. This configuration is shown to exhibit a number of characteristics that improve the performance of traditional time-of-flight secondary ion mass spectrometry (SIMS) experiments for the analysis of complex organic materials, and potentially, for chemical imaging. Specifically, the primary ion beam is operated as a continuous rather than a pulsed beam, resulting in up to 4 orders of magnitude greater ion fluence on the target. The secondary ions are extracted at very low voltage into 8 millitorr of N2 gas introduced for collisional focusing and cooling purposes. This extraction configuration is shown to yield secondary ions that rapidly lose memory of the mechanism of their birth, yielding tandem mass spectra that are identical for SIMS and MALDI. With implementation of ion trapping, the extraction efficiency is shown to be equivalent to that found in traditional TOF-SIMS machines. Examples are given, for a variety of substrates that illustrate mass resolution of 12,000–15,600 with mass range for inorganic compounds to m/z 40,000. Preliminary chemical mapping experiments show that with added sensitivity, imaging in the MS/MS mode of operation is straightforward. In general, the combination of MALDI and SIMS is shown to add capabilities to each technique, providing a robust platform for TOF-SIMS experiments that already exists in a large number of laboratories. PMID:18844371

  19. Inorganic Salt Interference on CO2(+) in Aerodyne AMS and ACSM Organic Aerosol Composition Studies.

    PubMed

    Pieber, Simone M; El Haddad, Imad; Slowik, Jay G; Canagaratna, Manjula R; Jayne, John T; Platt, Stephen M; Bozzetti, Carlo; Daellenbach, Kaspar R; Fröhlich, Roman; Vlachou, Athanasia; Klein, Felix; Dommen, Josef; Miljevic, Branka; Jiménez, José L; Worsnop, Douglas R; Baltensperger, Urs; Prévôt, André S H

    2016-10-04

    Aerodyne aerosol mass spectrometer (AMS) and Aerodyne aerosol chemical speciation monitor (ACSM) mass spectra are widely used to quantify organic aerosol (OA) elemental composition, oxidation state, and major environmental sources. The OA CO2(+) fragment is among the most important measurements for such analyses. Here, we show that a non-OA CO2(+) signal can arise from reactions on the particle vaporizer, ion chamber, or both, induced by thermal decomposition products of inorganic salts. In our tests (eight instruments, n = 29), ammonium nitrate (NH4NO3) causes a median CO2(+) interference signal of +3.4% relative to nitrate. This interference is highly variable between instruments and with measurement history (percentiles P10-90 = +0.4 to +10.2%). Other semi-refractory nitrate salts showed 2-10 times enhanced interference compared to that of NH4NO3, while the ammonium sulfate ((NH4)2SO4) induced interference was 3-10 times lower. Propagation of the CO2(+) interference to other ions during standard AMS and ACSM data analysis affects the calculated OA mass, mass spectra, molecular oxygen-to-carbon ratio (O/C), and f44. The resulting bias may be trivial for most ambient data sets but can be significant for aerosol with higher inorganic fractions (>50%), e.g., for low ambient temperatures, or laboratory experiments. The large variation between instruments makes it imperative to regularly quantify this effect on individual AMS and ACSM systems.

  20. Real-time 3D video utilizing a compressed sensing time-of-flight single-pixel camera

    NASA Astrophysics Data System (ADS)

    Edgar, Matthew P.; Sun, Ming-Jie; Gibson, Graham M.; Spalding, Gabriel C.; Phillips, David B.; Padgett, Miles J.

    2016-09-01

    Time-of-flight 3D imaging is an important tool for applications such as remote sensing, machine vision and autonomous navigation. Conventional time-of-flight three-dimensional imaging systems that utilize a raster scanned laser to measure the range of each pixel in the scene sequentially, inherently have acquisition times that scale directly with the resolution. Here we show a modified time-of-flight 3D camera employing structured illumination, which uses a visible camera to enable a novel compressed sensing technique, minimising the acquisition time as well as providing a high-resolution reflectivity map for image overlay. Furthermore, a quantitative assessment of the 3D imaging performance is provided.

  1. HYSPEC : A CRYSTAL TIME OF FLIGHT HYBRID SPECTROMETER FOR THE SPALLATION NEUTRON SOURCE.

    SciTech Connect

    SHAPIRO,S.M.; ZALIZNYAK,I.A.

    2002-12-30

    This document lays out a proposal by the Instrument Development Team (IDT) composed of scientists from leading Universities and National Laboratories to design and build a conceptually new high-flux inelastic neutron spectrometer at the pulsed Spallation Neutron Source (SNS) at Oak Ridge. This instrument is intended to supply users of the SNS and scientific community, of which the IDT is an integral part, with a platform for ground-breaking investigations of the low-energy atomic-scale dynamical properties of crystalline solids. It is also planned that the proposed instrument will be equipped with a polarization analysis capability, therefore becoming the first polarized beam inelastic spectrometer in the SNS instrument suite, and the first successful polarized beam inelastic instrument at a pulsed spallation source worldwide. The proposed instrument is designed primarily for inelastic and elastic neutron spectroscopy of single crystals. In fact, the most informative neutron scattering studies of the dynamical properties of solids nearly always require single crystal samples, and they are almost invariably flux-limited. In addition, in measurements with polarization analysis the available flux is reduced through selection of the particular neutron polarization, which puts even more stringent limits on the feasibility of a particular experiment. To date, these investigations have mostly been carried out on crystal spectrometers at high-flux reactors, which usually employ focusing Bragg optics to concentrate the neutron beam on a typically small sample. Construction at Oak Ridge of the high-luminosity spallation neutron source, which will provide intense pulsed neutron beams with time-averaged fluxes equal to those at medium-flux reactors, opens entirely new opportunities for single crystal neutron spectroscopy. Drawing upon experience acquired during decades of studies with both crystal and time-of-flight (TOF) spectrometers, the IDT has developed a conceptual

  2. High-speed digitization readout of silicon photomultipliers for time of flight positron emission tomography

    SciTech Connect

    Ronzhin, A.; Los, S.; Martens, M.; Ramberg, E.; Kim, H.; Chen, C.; Kao, C.; Niessen, K.; Zatserklyaniy, A.; Mazzillo, M.; Carbone, B.; /SGS Thomson, Catania

    2011-02-01

    We report on work to develop a system with about 100 picoseconds (ps) time resolution for time of flight positron emission tomography [TOF-PET]. The chosen photo detectors for the study were Silicon Photomultipliers (SiPM's). This study was based on extensive experience in studying timing properties of SiPM's. The readout of these devices used the commercial high speed digitizer DRS4. We applied different algorithms to get the best time resolution of 155 ps Guassian (sigma) for a LYSO crystal coupled to a SiPM. We consider the work as a first step in building a prototype TOF-PET module. The field of positron-emission-tomography (PET) has been rapidly developing. But there are significant limitations in how well current PET scanners can reconstruct images, related to how fast data can be acquired, how much volume they can image, and the spatial and temporal resolution of the generated photons. Typical modern scanners now include multiple rings of detectors, which can image a large volume of the patient. In this type of scanner, one can treat each ring as a separate detector and require coincidences only within the ring, or treat the entire region viewed by the scanner as a single 3 dimensional volume. This 3d technique has significantly better sensitivity since more photon pair trajectories are accepted. However, the scattering of photons within the volume of the patient, and the effect of random coincidences limits the technique. The advent of sub-nanosecond timing resolution detectors means that there is potentially much better rejection of scattered photon events and random coincidence events in the 3D technique. In addition, if the timing is good enough, then the origin of photons pairs can be determined better, resulting in improved spatial resolution - so called 'Time-of-Flight' PET, or TOF-PET. Currently a lot of activity has occurred in applications of SiPMs for TOF-PET. This is due to the devices very good time resolution, low profile, lack of high voltage

  3. Development and Validation of a New Blade Element Momentum Skewed-Wake Model within AeroDyn: Preprint

    SciTech Connect

    Ning, S. A.; Hayman, G.; Damiani, R.; Jonkman, J.

    2014-12-01

    Blade element momentum methods, though conceptually simple, are highly useful for analyzing wind turbines aerodynamics and are widely used in many design and analysis applications. A new version of AeroDyn is being developed to take advantage of new robust solution methodologies, conform to a new modularization framework for National Renewable Energy Laboratory's FAST, utilize advanced skewed-wake analysis methods, fix limitations with previous implementations, and to enable modeling of highly flexible and nonstraight blades. This paper reviews blade element momentum theory and several of the options available for analyzing skewed inflow. AeroDyn implementation details are described for the benefit of users and developers. These new options are compared to solutions from the previous version of AeroDyn and to experimental data. Finally, recommendations are given on how one might select from the various available solution approaches.

  4. Time-of-flight technique for particle identification at energies from 2 to 400 keV/nucleon

    NASA Technical Reports Server (NTRS)

    Gloeckler, G.; Hsieh, K. C.

    1979-01-01

    The time of flight technique for particle identification was extended to 2 keV/nucleon and the size of the start-time detector was reduced considerably by the use of carbon foils of few micrograms/cm square in thickness combined with microchannel plates for detecting secondary electrons. Time of flight telescopes incorporating this start-time device were used to measure the stopping power of a number of low energy heavy ions in thin carbon foils and the charge states of these ions emerging from such foils. Applications for the detection and identification of low energy interplanetary and magnetospheric particles are suggested.

  5. A fast preamplifier concept for SiPM-based time-of-flight PET detectors

    NASA Astrophysics Data System (ADS)

    Huizenga, J.; Seifert, S.; Schreuder, F.; van Dam, H. T.; Dendooven, P.; Löhner, H.; Vinke, R.; Schaart, D. R.

    2012-12-01

    Silicon photomultipliers (SiPMs) offer high gain and fast response to light, making them interesting for fast timing applications such as time-of-flight (TOF) PET. To fully exploit the potential of these photosensors, dedicated preamplifiers that do not deteriorate the rise time and signal-to-noise ratio are crucial. Challenges include the high sensor capacitance, typically >300 pF for a 3 mm×3 mm SiPM sensor, as well as oscillation issues. Here we present a preamplifier concept based on low noise, high speed transistors, designed for optimum timing performance. The input stage consists of a transimpedance common-base amplifier with a very low input impedance even at high frequencies, which assures a good linearity and avoids that the high detector capacitance affects the amplifier bandwidth. The amplifier has a fast timing output as well as a 'slow' energy output optimized for determining the total charge content of the pulse. The rise time of the amplifier is about 300 ps. The measured coincidence resolving time (CRT) for 511 keV photon pairs using the amplifiers in combination with 3 mm×3 mm SiPMs (Hamamatsu MPPC-S10362-33-050C) coupled to 3 mm×3 mm×5 mm LaBr3:Ce and LYSO:Ce crystals equals 95 ps FWHM and 138 ps FWHM, respectively.

  6. Impulse responses of visible phototubes used in National Ignition Facility neutron time of flight diagnostics

    NASA Astrophysics Data System (ADS)

    Datte, P. S.; Eckart, M.; Moore, A. S.; Thompson, W.; Vergel de Dios, G.

    2016-11-01

    Neutron-induced visible scintillation in neutron time of flight (NToF) diagnostics at the National Ignition Facility (NIF) is measured with 40 mm single stage micro-channel plate photomultipliers and a 40 mm vacuum photodiode, outside the neutron line of sight. In NIF experiments with 14 MeV neutron yields above Y > 10 × 1015 these tubes are configured to deliver of order 1 nC of charge in the nominally 5 ns NToF into a 50 Ω load. We have examined a number of 40 mm tubes manufactured by Photek Ltd. of St. Leonards on Sea, UK, to determine possible changes in the instrument impulse response as a function of signal charge delivered in 1 ns. Precision NToF measurements at approximately 20 m require that we characterize changes in the impulse response moments to <40 ps for the first central moment and ˜2% rms for the square root of the second central moment with ˜500 ps value. Detailed results are presented for three different diode configurations.

  7. Facile time-of-flight methods for characterizing pulsed superfluid helium droplet beams

    SciTech Connect

    He, Yunteng; Zhang, Jie; Li, Yang; Freund, William M.; Kong, Wei

    2015-08-15

    We present two facile time-of-flight (TOF) methods of detecting superfluid helium droplets and droplets with neutral dopants. Without an electron gun and with only a heated filament and pulsed electrodes, the electron impact ionization TOF mass spectrometer can resolve ionized helium clusters such as He{sub 2}{sup +} and He{sub 4}{sup +}, which are signatures of superfluid helium droplets. Without ionizing any helium atoms, multiphoton non-resonant laser ionization of CCl{sub 4} doped in superfluid helium droplets at 266 nm generates complex cluster ions of dopant fragments with helium atoms, including (He){sub n}C{sup +}, (He){sub n}Cl{sup +}, and (He){sub n}CCl{sup +}. Using both methods, we have characterized our cryogenic pulsed valve—the Even-Lavie valve. We have observed a primary pulse with larger helium droplets traveling at a slower speed and a rebound pulse with smaller droplets at a faster speed. In addition, the pickup efficiency of dopant is higher for the primary pulse when the nozzle temperature is higher than 13 K, and the total time duration of the doped droplet pulse is only on the order of 20 μs. These results stress the importance of fast and easy characterization of the droplet beam for sensitive measurements such as electron diffraction of doped droplets.

  8. The Time of Flight Upgrade for CLAS at 12 GeV

    SciTech Connect

    Graham, Lewis

    2007-10-26

    The Time of Flight (TOF) system is a detection system within the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson National Accelerator Facility. CLAS, being a magnetic toroidal multi-gap spectrometer, is used in the detection of particles and their varying properties. Jefferson National Accelerator Facility is providing an incoming electron beam of energy 6 GeV that is used to probe the structure and production of these particles. The CLAS detector is currently adapted to energies of up to 6 GeV, but with recent approval it will now upgrade to energies of 12 GeV. CLAS consists of drift chambers to determine the charged particle paths, gas Cherenkov counters for electron discrimination, TOF scintillators for particle identification, and an electromagnetic calorimeter for identifying showering electrons and photons. The TOF system, which is our focus, is composed of scintillation counters at the forward angle, and covers an area of 206 meters squared. Therefore, we look to upgrade and construct the TOF system of CLAS and outline strategies of current construction, purpose for design, and outlook for the TOF system upgrade.

  9. LSO background radiation as a transmission source using time of flight

    NASA Astrophysics Data System (ADS)

    Rothfuss, Harold; Panin, Vladimir; Moor, Andrew; Young, John; Hong, Inki; Michel, Christian; Hamill, James; Casey, Michael

    2014-09-01

    LSO scintillators (Lu2Sio5:Ce) have a background radiation which originates from the isotope Lu-176 that is present in natural occurring lutetium. The decay that occurs in this isotope is a beta decay that is in coincidence with cascade gamma emissions with energies of 307,202 and 88 keV. The coincidental nature of the beta decay with the gamma emissions allow for separation of emission data originating from a positron annihilation event from transmission type data from the Lu-176 beta decay. By using the time of flight information, and information of the chord length between two LSO pixels in coincidence as a result of a beta emission and emitted gamma, a second time window can be set to observe transmission events simultaneously to emission events. Using the time when the PET scanner is not actively acquiring positron emission data, a continuous blank can be acquired and used to reconstruct a transmission image. With this blank and the measured transmission data, a transmission image can be reconstructed. This reconstructed transmission image can be used to perform emission data corrections such as attenuation correction and scatter corrections or starting images for algorithms that estimate emission and attenuation simultaneously. It is observed that the flux of the background activity is high enough to create useful transmission images with an acquisition time of 10 min.

  10. Sensitivity estimation in time-of-flight list-mode positron emission tomography

    SciTech Connect

    Herraiz, J. L.; Sitek, A.

    2015-11-15

    Purpose: An accurate quantification of the images in positron emission tomography (PET) requires knowing the actual sensitivity at each voxel, which represents the probability that a positron emitted in that voxel is finally detected as a coincidence of two gamma rays in a pair of detectors in the PET scanner. This sensitivity depends on the characteristics of the acquisition, as it is affected by the attenuation of the annihilation gamma rays in the body, and possible variations of the sensitivity of the scanner detectors. In this work, the authors propose a new approach to handle time-of-flight (TOF) list-mode PET data, which allows performing either or both, a self-attenuation correction, and self-normalization correction based on emission data only. Methods: The authors derive the theory using a fully Bayesian statistical model of complete data. The authors perform an initial evaluation of algorithms derived from that theory and proposed in this work using numerical 2D list-mode simulations with different TOF resolutions and total number of detected coincidences. Effects of randoms and scatter are not simulated. Results: The authors found that proposed algorithms successfully correct for unknown attenuation and scanner normalization for simulated 2D list-mode TOF-PET data. Conclusions: A new method is presented that can be used for corrections for attenuation and normalization (sensitivity) using TOF list-mode data.

  11. Time-of-flights and traps: from the Histone Code to Mars*

    PubMed Central

    Swatkoski, Stephen; Becker, Luann; Evans-Nguyen, Theresa

    2011-01-01

    Two very different analytical instruments are featured in this perspective paper on mass spectrometer design and development. The first instrument, based upon the curved-field reflectron developed in the Johns Hopkins Middle Atlantic Mass Spectrometry Laboratory, is a tandem time-of-flight mass spectrometer whose performance and practicality are illustrated by applications to a series of research projects addressing the acetylation, deacetylation and ADP-ribosylation of histone proteins. The chemical derivatization of lysine-rich, hyperacetylated histones as their deuteroacetylated analogs enables one to obtain an accurate quantitative assessment of the extent of acetylation at each site. Chemical acetylation of histone mixtures is also used to determine the lysine targets of sirtuins, an important class of histone deacetylases (HDACs), by replacing the deacetylated residues with biotin. Histone deacetylation by sirtuins requires the co-factor NAD+, as does the attachment of ADP-ribose. The second instrument, a low voltage and low power ion trap mass spectrometer known as the Mars Organic Mass Analyzer (MOMA), is a prototype for an instrument expected to be launched in 2018. Like the tandem mass spectrometer, it is also expected to have applicability to environmental and biological analyses and, ultimately, to clinical care. PMID:20530839

  12. Liquid chromatography quadrupole time-of-flight mass spectrometry selective determination of ochratoxin A in wine.

    PubMed

    Rodríguez-Cabo, T; Rodríguez, I; Ramil, M; Cela, R

    2016-05-15

    The performance of liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) for ochratoxin A (OTA) determination in wine is evaluated for the first time. Sample preparation was optimized to obtain quantitative recoveries at the same time that the efficiency of electrospray ionization (ESI) remained unaltered between sample extracts and calibration standards. Under final conditions, samples (20 mL) were concentrated using a reversed-phase solid-phase extraction (SPE) cartridge, followed by OTA elution with 1 mL of ethyl acetate. The absolute recoveries of the method, established against calibration standards, were 91-121% and 90-113% (without and with internal standard correction, respectively), for wines fortified at 3 concentration levels. The attained LOQ (0.05 ng mL(-1)) remained below the maximum permitted OTA concentration (2 ng mL(-1)) in dry wines. The method was applied to different samples, with OTA being found in some dessert wines at concentrations below 1 ng mL(-1). The ethyl ester of OTA (OTC) could be identified in the same wine samples from its accurate full product ion spectra.

  13. Measuring time-of-flight in an ultrasonic LPS system using generalized cross-correlation.

    PubMed

    Villladangos, José Manuel; Ureña, Jesús; García, Juan Jesús; Mazo, Manuel; Hernández, Alvaro; Jiménez, Ana; Ruíz, Daniel; De Marziani, Carlos

    2011-01-01

    In this article, a time-of-flight detection technique in the frequency domain is described for an ultrasonic local positioning system (LPS) based on encoded beacons. Beacon transmissions have been synchronized and become simultaneous by means of the DS-CDMA (direct-sequence code Division multiple access) technique. Every beacon has been associated to a 255-bit Kasami code. The detection of signal arrival instant at the receiver, from which the distance to each beacon can be obtained, is based on the application of the generalized cross-correlation (GCC), by using the cross-spectral density between the received signal and the sequence to be detected. Prior filtering to enhance the frequency components around the carrier frequency (40 kHz) has improved estimations when obtaining the correlation function maximum, which implies an improvement in distance measurement precision. Positioning has been achieved by using hyperbolic trilateration, based on the time differences of arrival (TDOA) between a reference beacon and the others.

  14. Crystal timing offset calibration method for time of flight PET scanners

    NASA Astrophysics Data System (ADS)

    Ye, Jinghan; Song, Xiyun

    2016-03-01

    In time-of-flight (TOF) positron emission tomography (PET), precise calibration of the timing offset of each crystal of a PET scanner is essential. Conventionally this calibration requires a specially designed tool just for this purpose. In this study a method that uses a planar source to measure the crystal timing offsets (CTO) is developed. The method uses list mode acquisitions of a planar source placed at multiple orientations inside the PET scanner field-of-view (FOV). The placement of the planar source in each acquisition is automatically figured out from the measured data, so that a fixture for exactly placing the source is not required. The expected coincidence time difference for each detected list mode event can be found from the planar source placement and the detector geometry. A deviation of the measured time difference from the expected one is due to CTO of the two crystals. The least squared solution of the CTO is found iteratively using the list mode events. The effectiveness of the crystal timing calibration method is evidenced using phantom images generated by placing back each list mode event into the image space with the timing offset applied to each event. The zigzagged outlines of the phantoms in the images become smooth after the crystal timing calibration is applied. In conclusion, a crystal timing calibration method is developed. The method uses multiple list mode acquisitions of a planar source to find the least squared solution of crystal timing offsets.

  15. Implementation of Dipolar Resonant Excitation Collision Induced Dissociation with Ion Mobility/Time-of-Flight MS

    SciTech Connect

    Webb, Ian K.; Chen, Tsung-Chi; Danielson, William F.; Ibrahim, Yehia M.; Tang, Keqi; Anderson, Gordon A.; Smith, Richard D.

    2014-01-28

    Under and overfragmentation are significant hurdles to the data independent “bottom-up” approach to proteomics. Another challenge to the data independent approach is the convolution of fragments from different peptides that coelute in reverse-phase liquid chromatography/mass spectrometry (RPLC/MS). The ion mobility/collision induced dissociation/time-of flight mass spectrometry (IMS/CID/TOF MS) approach gives drift-time aligned fragment ions that have the same arrival time distributions as precursor ions, greatly aiding in fragment and peptide ion identification. We have modified an IMS/TOF MS platform to allow for resonant excitation CID experiments. Resonant excitation CID leads to highly efficient, mass-resolved fragmentation without additional excitation of product ions, alleviating the overfragmentation problem. The ability to apply resonant waveforms in mobility-resolved windows has been demonstrated with a peptide mixture yielding fragmentation over a range of mass-to-charge (m/z) ratios within a single IMS separation experiment.

  16. Facile time-of-flight methods for characterizing pulsed superfluid helium droplet beams.

    PubMed

    He, Yunteng; Zhang, Jie; Li, Yang; Freund, William M; Kong, Wei

    2015-08-01

    We present two facile time-of-flight (TOF) methods of detecting superfluid helium droplets and droplets with neutral dopants. Without an electron gun and with only a heated filament and pulsed electrodes, the electron impact ionization TOF mass spectrometer can resolve ionized helium clusters such as He2(+) and He4(+), which are signatures of superfluid helium droplets. Without ionizing any helium atoms, multiphoton non-resonant laser ionization of CCl4 doped in superfluid helium droplets at 266 nm generates complex cluster ions of dopant fragments with helium atoms, including (He)(n)C(+), (He)(n)Cl(+), and (He)(n)CCl(+). Using both methods, we have characterized our cryogenic pulsed valve—the Even-Lavie valve. We have observed a primary pulse with larger helium droplets traveling at a slower speed and a rebound pulse with smaller droplets at a faster speed. In addition, the pickup efficiency of dopant is higher for the primary pulse when the nozzle temperature is higher than 13 K, and the total time duration of the doped droplet pulse is only on the order of 20 μs. These results stress the importance of fast and easy characterization of the droplet beam for sensitive measurements such as electron diffraction of doped droplets.

  17. Novel time-of-flight spectrometer for the analysis of positron annihilation induced Auger electrons

    SciTech Connect

    Hugenschmidt, Christoph; Legl, Stefan

    2006-10-15

    Positron annihilation induced Auger-electron spectroscopy (PAES) has several advantages over conventional Auger-electron spectroscopy such as extremely high surface sensitivity and outstanding signal-to-noise ratio at the Auger-transition energy. In order to benefit from these prominent features a low-energy positron beam of high intensity is required for surface sensitive PAES studies. In addition, an electron energy analyzer is required, which efficiently detects the Auger electrons with acceptable energy resolution. For this reason a novel time-of-flight (TOF) spectrometer has been developed at the intense positron source NEPOMUC that allows PAES studies within short measurement time. This TOF-PAES setup combines a trochoidal filter and a flight tube in a Faraday cage in order to achieve an improved energy resolution of about 1 eV at high electron energies up to E{approx_equal}1000 eV. The electron flight time is the time between the annihilation radiation at the sample and when the electron hits a microchannel plate detector at the end of the flight tube.

  18. Context-aware fall detection using inertial sensors and time-of-flight transceivers.

    PubMed

    Shastry, Mahesh C; Asgari, Meysam; Wan, Eric A; Leitschuh, Joseph; Preiser, Nicholas; Folsom, Jon; Condon, John; Cameron, Michelle; Jacobs, Peter G

    2016-08-01

    Automatic detection of falls is important for enabling people who are older to safely live independently longer within their homes. Current automated fall detection systems are typically designed using inertial sensors positioned on the body that generate an alert if there is an abrupt change in motion. These inertial sensors provide no information about the context of the person being monitored and are prone to false positives that can limit their ongoing usage. We describe a fall-detection system consisting of a wearable inertial measurement unit (IMU) and an RF time-of-flight (ToF) transceiver that ranges with other ToF beacons positioned throughout a home. The ToF ranging enables the system to track the position of the person as they move around a home. We describe and show results from three machine learning algorithms that integrate context-related position information with IMU based fall detection to enable a deeper understanding of where falls are occurring and also to improve the specificity of fall detection. The beacons used to localize the falls were able to accurately track to within 0.39 meters of specific waypoints in a simulated home environment. Each of the three algorithms was evaluated with and without the context-based false alarm detection on simulated falls done by 3 volunteer subjects in a simulated home. False positive rates were reduced by 50% when including context.

  19. LSO background radiation as a transmission source using time of flight.

    PubMed

    Rothfuss, Harold; Panin, Vladimir; Moor, Andrew; Young, John; Hong, Inki; Michel, Christian; Hamill, James; Casey, Michael

    2014-09-21

    LSO scintillators (Lu2Sio5:Ce) have a background radiation which originates from the isotope Lu-176 that is present in natural occurring lutetium. The decay that occurs in this isotope is a beta decay that is in coincidence with cascade gamma emissions with energies of 307,202 and 88 keV. The coincidental nature of the beta decay with the gamma emissions allow for separation of emission data originating from a positron annihilation event from transmission type data from the Lu-176 beta decay. By using the time of flight information, and information of the chord length between two LSO pixels in coincidence as a result of a beta emission and emitted gamma, a second time window can be set to observe transmission events simultaneously to emission events. Using the time when the PET scanner is not actively acquiring positron emission data, a continuous blank can be acquired and used to reconstruct a transmission image. With this blank and the measured transmission data, a transmission image can be reconstructed. This reconstructed transmission image can be used to perform emission data corrections such as attenuation correction and scatter corrections or starting images for algorithms that estimate emission and attenuation simultaneously. It is observed that the flux of the background activity is high enough to create useful transmission images with an acquisition time of 10 min.

  20. CVD Diamond Detectors for Current Mode Neutron Time-of-Flight Spectroscopy at OMEGA/NIF

    SciTech Connect

    G. J. Schmid; V. Yu. Glebov; A. V. Friensehner; D. R. Hargrove; S. P. Hatchett; N. Izumi; R. A. Lerche; T. W. Phillips; T. C. Sangster; C. Silbernagel; C. Stoecki

    2001-07-01

    We have performed pulsed neutron and pulsed laser tests of a CVD diamond detector manufactured from DIAFILM, a commercial grade of CVD diamond. The laser tests were performed at the short pulse UV laser at Bechtel Nevada in Livermore, CA. The pulsed neutrons were provided by DT capsule implosions at the OMEGA laser fusion facility in Rochester, NY. From these tests, we have determined the impulse response to be 250 ps fwhm for an applied E-field of 500 V/mm. Additionally, we have determined the sensitivity to be 2.4 mA/W at 500 V/mm and 4.0 mA/W at 1000 V/mm. These values are approximately 2 to 5x times higher than those reported for natural Type IIa diamond at similar E-field and thickness (1mm). These characteristics allow us to conceive of a neutron time-of-flight current mode spectrometer based on CVD diamond. Such an instrument would sit inside the laser fusion target chamber close to target chamber center (TCC), and would record neutron spectra fast enough such that backscattered neutrons and x-rays from the target chamber wall would not be a concern. The acquired neutron spectra could then be used to extract DD fuel areal density from the downscattered secondary to secondary ratio.

  1. Study of Scattered Background Neutron in NIF and Time-of Flight (TOF) to Measure Neutron

    SciTech Connect

    Song, P; Moran, M; Phillips, T; Lerche, R; Koch, J; Eder, D

    2005-08-31

    Some of the planned core diagnostics for National Ignition Facility (NIF) will use neutron time-of-flight (TOF) spectroscopy techniques to gather information for primary neutron yield measurement or neutron imaging. This technique has been widely and routinely used at other laser facilities including Nova and Omega. TOF methods will also be used to observe target fuel areal density <{rho}R> (radial integral of density) via measuring the number of primary 14.1 MeV neutrons that are down-scattered to lower energies by nuclear collisions inside the compressed target core. The substantially larger target chamber size and higher neutron yield for NIF raises issues related to the large number of scattered neutrons produced by high yield deuterium-tritium (D-T) shots at NIF. The effect of primary neutrons scattered by the walls of the massive target chamber and structures both inside and outside the chamber will contribute a significant scattered background signal when trying to determine the number of neutrons down-scattered from the target core. The optimum detector locations outside the target chamber or target bay wall will be proposed. Appropriate collimators at the chamber port and the bay wall (between the neutron source at target chamber center (TCC) and detector) that maximize detection of signal neutrons while minimizing the background from scattered neutrons and neutron induced gamma rays will also be presented.

  2. CVD Diamond Detectors for Current Mode Neutron Time-of-Flight Spectroscopy at OMEGA/NIF

    SciTech Connect

    Schmid, G J; Friensehner, A F; Glebov, V Y; Hargrove, D R; Hatchett, S P; Izumi, N; Lerche, R A; Phillips, T W; Sangster, T C; Sibernagel, C; Stoeckl, C

    2001-06-19

    As part of a laser fusion diagnostic development program, we have performed pulsed neutron and pulsed laser tests of a CVD diamond detector manufactured from DIAFILM, a commercial grade of CVD diamond. The laser tests were performed at the short pulse UV laser at Bechtel Nevada in Livermore, CA. The pulsed neutrons were provided by DT capsule implosions at the OMEGA laser fusion facility in Rochester, NY. From these tests, we have determined the impulse response to be 250 ps fwhm for an applied E-field of 500 V/mm. Additionally, we have determined the sensitivity to be 2.8 mA/W at 500 V/mm and 4.5 mA/W at 1000 V/mm (2 to 6x times higher than reported values for natural Type IIa diamond). These detector characteristics allow us to conceive of a neutron time-of-flight current mode spectrometer based on CVD diamond. Such an instrument would sit inside the laser fusion target chamber close to TCC, and would record neutron spectra fast enough such that backscattered neutrons and y rays from the target chamber wall would not be a concern. However, the data we have taken show that the Electromagnetic Pulse (EMP) noise could be a limiting factor in performance. Determining the degree to which this noise can be shielded will be an important subject of future tests.

  3. Analysis of the neutron time-of-flight spectra from inertial confinement fusion experiments

    NASA Astrophysics Data System (ADS)

    Hatarik, R.; Sayre, D. B.; Caggiano, J. A.; Phillips, T.; Eckart, M. J.; Bond, E. J.; Cerjan, C.; Grim, G. P.; Hartouni, E. P.; Knauer, J. P.; Mcnaney, J. M.; Munro, D. H.

    2015-11-01

    Neutron time-of-flight diagnostics have long been used to characterize the neutron spectrum produced by inertial confinement fusion experiments. The primary diagnostic goals are to extract the d + t → n + α (DT) and d + d → n + 3He (DD) neutron yields and peak widths, and the amount DT scattering relative to its unscattered yield, also known as the down-scatter ratio (DSR). These quantities are used to infer yield weighted plasma conditions, such as ion temperature (Tion) and cold fuel areal density. We report on novel methodologies used to determine neutron yield, apparent Tion, and DSR. These methods invoke a single temperature, static fluid model to describe the neutron peaks from DD and DT reactions and a spline description of the DT spectrum to determine the DSR. Both measurements are performed using a forward modeling technique that includes corrections for line-of-sight attenuation and impulse response of the detection system. These methods produce typical uncertainties for DT Tion of 250 eV, 7% for DSR, and 9% for the DT neutron yield. For the DD values, the uncertainties are 290 eV for Tion and 10% for the neutron yield.

  4. Matrix assisted laser desorption time of flight mass spectrometry (MALDI-TOF MS) in clinical microbiology.

    PubMed

    Angeletti, Silvia

    2016-09-06

    The microbiological management of patients with suspected bacterial infection includes the identification of the pathogen and the determination of the antibiotic susceptibility. These traditional approaches, based on the pure culture of the microorganism, require at least 36-48h. A new method, Matrix Assisted Laser Desorption Ionization Time of Flight Mass Spectrometry (MALDI-TOF MS), has been recently developed to profile bacterial proteins from whole cell extracts and obtain a bacterial fingerprint able to discriminate microorganisms from different genera and species. By whole cell-mass spectrometry, microbial identification can be achieved within minutes from cultured isolate, rather than traditional phenotypic or genotypic characterizations. From the year 2009 an explosion of applications of this technology has been observed with promising results. Several studies have been performed and showed that MALDI-TOF represents a reliable alternative method for rapid bacteria and fungi identification in clinical setting. A future area of expansion is represented by the application of MALDI-TOF technology to the antibiotic susceptibility test. In conclusion, the revision of the literature available up to date demonstrated that MALDI-TOF MS represents an innovative technology for the rapid and accurate identification of bacterial and fungal isolates in clinical settings. By an earlier microbiological diagnosis, MALDI-TOF MS contributes to a reduced mortality and hospitalization time of the patients and consequently has a significant impact on cost savings and public health.

  5. Multiplexed Ion Mobility Spectrometry - Orthogonal Time-Of-Flight Mass Spectrometry

    SciTech Connect

    Belov, Mikhail E.; Buschbach, Michael A.; Prior, David C.; Tang, Keqi; Smith, Richard D.

    2007-03-15

    Ion mobility spectrometry (IMS) coupled to orthogonal time-of-flight mass spectrometry (TOF) has shown significant promise for the characterization of complex biological mixtures. The enormous complexity of biological samples (e.g. from proteomics) and the need for both biological and technical analysis replicates imposes major challenges for multidimensional separation platforms in regard to both sensitivity and sample throughput. A major potential attraction of the IMS-TOF MS platform is separation speeds exceeding that of conventional condensed-phase separations by orders of magnitude. Known limitations of the IMS-TOF MS platforms that presently mitigate this attraction include the need for extensive signal averaging due to factors that include significant ion losses in the IMS-TOF interface and an ion utilization efficiency of less than ~1% with continuous ion sources (e.g. ESI). We have developed a new multiplexed ESI-IMS-TOF mass spectrometer that enables lossless ion transmission through the IMS-TOF as well as a utilization efficiency of >50% for ions from the ESI source. Initial results with a mixture of peptides show a ~10-fold increase in signal-to-noise ratio with the multiplexed approach compared to a signal averaging approach, with no reduction in either IMS or TOF MS resolution.

  6. Depth Errors Analysis and Correction for Time-of-Flight (ToF) Cameras.

    PubMed

    He, Ying; Liang, Bin; Zou, Yu; He, Jin; Yang, Jun

    2017-01-05

    Time-of-Flight (ToF) cameras, a technology which has developed rapidly in recent years, are 3D imaging sensors providing a depth image as well as an amplitude image with a high frame rate. As a ToF camera is limited by the imaging conditions and external environment, its captured data are always subject to certain errors. This paper analyzes the influence of typical external distractions including material, color, distance, lighting, etc. on the depth error of ToF cameras. Our experiments indicated that factors such as lighting, color, material, and distance could cause different influences on the depth error of ToF cameras. However, since the forms of errors are uncertain, it's difficult to summarize them in a unified law. To further improve the measurement accuracy, this paper proposes an error correction method based on Particle Filter-Support Vector Machine (PF-SVM). Moreover, the experiment results showed that this method can effectively reduce the depth error of ToF cameras to 4.6 mm within its full measurement range (0.5-5 m).

  7. The Time of Flight Upgrade for CLAS at 12 GeV

    SciTech Connect

    Lewis Graham

    2007-10-01

    The Time of Flight (TOF) system is a detection system within the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson National Accelerator Facility. CLAS, being a magnetic toroidal multi-gap spectrometer, is used in the detection of particles and their varying properties. Jefferson National Accelerator Facility is providing an incoming electron beam of energy 6 GeV that is used to probe the structure and production of these particles. The CLAS detector is currently adapted to energies of up to 6 GeV, but with recent approval it will now upgrade to energies of 12 GeV. CLAS consists of drift chambers to determine the charged particle paths, gas Cherenkov counters for electron discrimination, TOF scintillators for particle identification, and an electromagnetic calorimeter for identifying showering electrons and photons. The TOF system, which is our focus, is composed of scintillation counters at the forward angle, and covers an area of 206 meters squared. Therefore, we look to upgrade and construct the TOF system of CLAS and outline strategies of current construction, purpose for design, and outlook for the TOF system upgrade

  8. Laser desorption time-of-flight mass spectrometry of ultraviolet photo-processed ices

    SciTech Connect

    Paardekooper, D. M. Bossa, J.-B.; Isokoski, K.; Linnartz, H.

    2014-10-01

    A new ultra-high vacuum experiment is described that allows studying photo-induced chemical processes in interstellar ice analogues. MATRI²CES - a Mass Analytical Tool to study Reactions in Interstellar ICES applies a new concept by combining laser desorption and time-of-flight mass spectrometry with the ultimate goal to characterize in situ and in real time the solid state evolution of organic compounds upon UV photolysis for astronomically relevant ice mixtures and temperatures. The performance of the experimental setup is demonstrated by the kinetic analysis of the different photoproducts of pure methane (CH₄) ice at 20 K. A quantitative approach provides formation yields of several new species with up to four carbon atoms. Convincing evidence is found for the formation of even larger species. Typical mass resolutions obtained range from M/ΔM ~320 to ~400 for CH₄ and argon, respectively. Additional tests show that the typical detection limit (in monolayers) is ⩽0.02 ML, substantially more sensitive than the regular techniques used to investigate chemical processes in interstellar ices.

  9. Development and characterization of an aircraft aerosol time-of-flight mass spectrometer.

    PubMed

    Pratt, Kerri A; Mayer, Joseph E; Holecek, John C; Moffet, Ryan C; Sanchez, Rene O; Rebotier, Thomas P; Furutani, Hiroshi; Gonin, Marc; Fuhrer, Katrin; Su, Yongxuan; Guazzotti, Sergio; Prather, Kimberly A

    2009-03-01

    Vertical and horizontal profiles of atmospheric aerosols are necessary for understanding the impact of air pollution on regional and global climate. To gain further insight into the size-resolved chemistry of individual atmospheric particles, a smaller aerosol time-of-flight mass spectrometer (ATOFMS) with increased data acquisition capabilities was developed for aircraft-based studies. Compared to previous ATOFMS systems, the new instrument has a faster data acquisition rate with improved ion transmission and mass resolution, as well as reduced physical size and power consumption, all required advances for use in aircraft studies. In addition, real-time source apportionment software allows the immediate identification and classification of individual particles to guide sampling decisions while in the field. The aircraft (A)-ATOFMS was field-tested on the ground during the Study of Organic Aerosols in Riverside, CA (SOAR) and aboard an aircraft during the Ice in Clouds Experiment-Layer Clouds (ICE-L). Initial results from ICE-L represent the first reported aircraft-based single-particle dual-polarity mass spectrometry measurements and provide an increased understanding of particle mixing state as a function of altitude. Improved ion transmission allows for the first single-particle detection of species out to approximately m/z 2000, an important mass range for the detection of biological aerosols and oligomeric species. In addition, high time resolution measurements of single-particle mixing state are demonstrated and shown to be important for airborne studies where particle concentrations and chemistry vary rapidly.

  10. Time-of-Flight Mass Measurements for Nuclear Processes in Neutron Star Crusts

    NASA Astrophysics Data System (ADS)

    Estradé, A.; Matoš, M.; Schatz, H.; Amthor, A. M.; Bazin, D.; Beard, M.; Becerril, A.; Brown, E. F.; Cyburt, R.; Elliot, T.; Gade, A.; Galaviz, D.; George, S.; Gupta, S. S.; Hix, W. R.; Lau, R.; Lorusso, G.; Möller, P.; Pereira, J.; Portillo, M.; Rogers, A. M.; Shapira, D.; Smith, E.; Stolz, A.; Wallace, M.; Wiescher, M.

    2011-10-01

    We present results from time-of-flight nuclear mass measurements at the National Superconducting Cyclotron Laboratory that are relevant for neutron star crust models. The masses of 16 neutron-rich nuclei in the scandium-nickel range were determined simultaneously, with the masses of V61, Cr63, Mn66, and Ni74 measured for the first time with mass excesses of -30.510(890)MeV, -35.280(650)MeV, -36.900(790)MeV, and -49.210(990)MeV, respectively. With these results the locations of the dominant electron capture heat sources in the outer crust of accreting neutron stars that exhibit super bursts are now experimentally constrained. We find the experimental Q value for the Fe66→Mn66 electron capture to be 2.1 MeV (2.6σ) smaller than predicted, resulting in the transition occurring significantly closer to the neutron star surface.

  11. Experimental evaluation of a simple lesion detection task with time-of-flight PET

    NASA Astrophysics Data System (ADS)

    Surti, S.; Karp, J. S.

    2009-01-01

    A new generation of high-performance, time-of-flight (TOF) PET scanners have recently been developed. In earlier works, the gain with TOF information was derived as a reduction of noise in the reconstructed image, or essentially a gain in scanner sensitivity. These derivations were applicable to analytical reconstruction techniques and 2D PET imaging. In this work, we evaluate the gain measured in the clinically relevant task of lesion detection with TOF information in fully 3D PET scanners using iterative reconstruction algorithms. We performed measurements in a fully 3D TOF PET scanner using spherical lesions in uniform, cylindrical phantom. Lesion detectability was estimated for 10 mm diameter lesions using a non-prewhitening matched filter signal-to-noise-ratio (NPW SNR) as the metric. Our results show that the use of TOF information leads to increased lesion detectability, which is achieved with less number of iterations of the reconstruction algorithm. These phantom results indicate that clinically, TOF PET will allow reduced scan times and improved lesion detectability, especially in large patients.

  12. Development of position-sensitive time-of-flight spectrometer for fission fragment research

    SciTech Connect

    Arnold, C. W.; Tovesson, F.; Meierbachtol, K.; Bredeweg, T.; Jandel, M.; Jorgenson, H. J.; Laptev, A.; Rusev, G.; Shields, D. W.; White, M.; Blakeley, R. E.; Mader, D. M.; Hecht, A. A.

    2014-07-09

    A position-sensitive, high-resolution time-of-flight detector for fission fragments has been developed. The SPectrometer for Ion DEtermination in fission Research (SPIDER) is a 2E–2v spectrometer designed to measure the mass of light fission fragments to a single mass unit. The time pick-off detector pairs to be used in SPIDER have been tested with α-particles from 229Th and its decay chain and α-particles and spontaneous fission fragments from 252Cf. Each detector module is comprised of thin electron conversion foil, electrostatic mirror, microchannel plates, and delay-line anodes. Particle trajectories on the order of 700 mm are determined accurately to within 0.7 mm. Flight times were measured with 250 ps resolution FWHM. Computed particle velocities are accurate to within 0.06 mm/ns corresponding to a precision of 0.5%. As a result, an ionization chamber capable of 400 keV energy resolution coupled with the velocity measurements described here will pave the way for modestly efficient measurements of light fission fragments with unit mass resolution.

  13. Sensitivity estimation in time-of-flight list-mode positron emission tomography

    PubMed Central

    Herraiz, J. L.; Sitek, A.

    2015-01-01

    Purpose: An accurate quantification of the images in positron emission tomography (PET) requires knowing the actual sensitivity at each voxel, which represents the probability that a positron emitted in that voxel is finally detected as a coincidence of two gamma rays in a pair of detectors in the PET scanner. This sensitivity depends on the characteristics of the acquisition, as it is affected by the attenuation of the annihilation gamma rays in the body, and possible variations of the sensitivity of the scanner detectors. In this work, the authors propose a new approach to handle time-of-flight (TOF) list-mode PET data, which allows performing either or both, a self-attenuation correction, and self-normalization correction based on emission data only. Methods: The authors derive the theory using a fully Bayesian statistical model of complete data. The authors perform an initial evaluation of algorithms derived from that theory and proposed in this work using numerical 2D list-mode simulations with different TOF resolutions and total number of detected coincidences. Effects of randoms and scatter are not simulated. Results: The authors found that proposed algorithms successfully correct for unknown attenuation and scanner normalization for simulated 2D list-mode TOF-PET data. Conclusions: A new method is presented that can be used for corrections for attenuation and normalization (sensitivity) using TOF list-mode data. PMID:26520759

  14. TOF (time-of-flight) measurements of pulsed neutrons for texture analysis of low symmetry materials

    SciTech Connect

    Larson, A.C.; Vergamini, P.J.; Lujan, M. Jr. ); Wenk, H.R. . Dept. of Geology and Geophysics)

    1989-01-01

    The single crystal diffractometer at LANSCE, SCD, provides and ideal capability for the study of preferred orientation in geological samples by time-of flight (TOF) measurement of pulsed neutrons. The 2-d position sensitive neutron detector with the large wave length range allows one to measure the complete distribution of intensities for several poles very quickly. Each histogram covers about {pi}{sup 2}/16 radians of reciprocal space and contains information from all possible poles visible with the wave length range used, usually about 0.5 to 5.0{Angstrom}. With this method complete pole figures of many lattice planes can be constructed from only 12 to 20 sample orientations as compared to over 1000 sample settings per lattice plane using conventional diffractometers. Pole figures from measurements of experimentally deformed standard samples of calcite and quartzite with known history of deformation provide information about deformation mechanisms and their temperature/strain history. This information can be applied to interpret preferred orientation of naturally deformed rocks. 6 refs., 10 figs.

  15. Analysis of the neutron time-of-flight spectra from inertial confinement fusion experiments

    SciTech Connect

    Hatarik, R. Sayre, D. B.; Caggiano, J. A.; Phillips, T.; Eckart, M. J.; Bond, E. J.; Cerjan, C.; Grim, G. P.; Hartouni, E. P.; Mcnaney, J. M.; Munro, D. H.; Knauer, J. P.

    2015-11-14

    Neutron time-of-flight diagnostics have long been used to characterize the neutron spectrum produced by inertial confinement fusion experiments. The primary diagnostic goals are to extract the d + t → n + α (DT) and d + d → n + {sup 3}He (DD) neutron yields and peak widths, and the amount DT scattering relative to its unscattered yield, also known as the down-scatter ratio (DSR). These quantities are used to infer yield weighted plasma conditions, such as ion temperature (T{sub ion}) and cold fuel areal density. We report on novel methodologies used to determine neutron yield, apparent T{sub ion}, and DSR. These methods invoke a single temperature, static fluid model to describe the neutron peaks from DD and DT reactions and a spline description of the DT spectrum to determine the DSR. Both measurements are performed using a forward modeling technique that includes corrections for line-of-sight attenuation and impulse response of the detection system. These methods produce typical uncertainties for DT T{sub ion} of 250 eV, 7% for DSR, and 9% for the DT neutron yield. For the DD values, the uncertainties are 290 eV for T{sub ion} and 10% for the neutron yield.

  16. Exploiting sparsity in time-of-flight range acquisition using a single time-resolved sensor.

    PubMed

    Kirmani, Ahmed; Colaço, Andrea; Wong, Franco N C; Goyal, Vivek K

    2011-10-24

    Range acquisition systems such as light detection and ranging (LIDAR) and time-of-flight (TOF) cameras operate by measuring the time difference of arrival between a transmitted pulse and the scene reflection. We introduce the design of a range acquisition system for acquiring depth maps of piecewise-planar scenes with high spatial resolution using a single, omnidirectional, time-resolved photodetector and no scanning components. In our experiment, we reconstructed 64 × 64-pixel depth maps of scenes comprising two to four planar shapes using only 205 spatially-patterned, femtosecond illuminations of the scene. The reconstruction uses parametric signal modeling to recover a set of depths present in the scene. Then, a convex optimization that exploits sparsity of the Laplacian of the depth map of a typical scene determines correspondences between spatial positions and depths. In contrast with 2D laser scanning used in LIDAR systems and low-resolution 2D sensor arrays used in TOF cameras, our experiment demonstrates that it is possible to build a non-scanning range acquisition system with high spatial resolution using only a standard, low-cost photodetector and a spatial light modulator.

  17. Time-of-flight mass spectrographs—From ions to neutral atoms

    NASA Astrophysics Data System (ADS)

    Möbius, E.; Galvin, A. B.; Kistler, L. M.; Kucharek, H.; Popecki, M. A.

    2016-12-01

    After their introduction to space physics in the mid 1980s time-of-flight (TOF) spectrographs have become a main staple in spaceborne mass spectrometry. They have largely replaced magnetic spectrometers, except when extremely high mass resolution is required to identify complex molecules, for example, in the vicinity of comets or in planetary atmospheres. In combination with electrostatic analyzers and often solid state detectors, TOF spectrographs have become key instruments to diagnose space plasma velocity distributions, mass, and ionic charge composition. With a variety of implementation schemes that also include isochronous electric field configurations, TOF spectrographs can respond to diverse science requirements. This includes a wide range in mass resolution to allow the separation of medium heavy isotopes or to simply provide distributions of the major species, such as H, He, and O, to obtain information on source tracers or mass fluxes. With a top-hat analyzer at the front end, or in combination with deflectors for three-axis stabilized spacecraft, the distribution function of ions can be obtained with good time resolution. Most recently, the reach of TOF ion mass spectrographs has been extended to include energetic neutral atoms. After selecting the arrival direction with mechanical collimation, followed by conversion to ions, adapted TOF sensors form a new branch of the spectrograph family tree. We review the requirements, challenges, and implementation schemes for ion and neutral atom spectrographs, including potential directions for the future, while largely avoiding overlap with complementary contributions in this special issue.

  18. Time-of-Flight Detector System with Low Background Performance for the IBEX-lo Sensor

    NASA Astrophysics Data System (ADS)

    Moebius, E.; Kucharek, H.; Granoff, M.; King, B.; Longworth, S.; Saul, L.; Fuselier, S.; Hertzberg, E.; Livi, S.; Paschalidis, N.; Schlemm, C.; Scheer, J.; Wurz, P.; Wieser, M.

    2006-12-01

    Over the course of the IBEX Mission the IBEX-lo sensor will provide images of energetic neutral H atoms (ENA) from the termination shock in the energy range 10 2000 eV as well as the directional flow distribution of interstellar neutral O in spring and fall. The sensor combines a mechanical collimator to restrict the detectable arrival directions, an atom to negative ion conversion surface, an electrostatic analyzer, post-acceleration of up to 20 keV, and time-of-flight (TOF) mass analysis. In this combination the TOF system provides the necessary mass separation to distinguish different species and effective background suppression through coincidence detection techniques. Because the flux of the heliospheric ENAs is very low and generates rather low count rates a triple coincidence system is used with secondary electrons produced in two consecutive carbon foils, followed by the final detection of the ions in a micro-channelplate. These three signals are combined into three independent TOF measurements. A flight-like engineering test unit of the IBEX-lo TOF subsystem has been built and tested. Meanwhile the flight model of the sensor is in fabrication. It will be shown that the combination of several TOF measurements provides very effective means to suppress background and to identify minor species, whose fluxes are several orders of magnitude below the main species. Results from the testing of the engineering unit will be discussed in the light of the IBEX science objectives.

  19. Development of a portable time-of-flight membrane inlet mass spectrometer for environmental analysis

    NASA Astrophysics Data System (ADS)

    White, A. J.; Blamire, M. G.; Corlett, C. A.; Griffiths, B. W.; Martin, D. M.; Spencer, S. B.; Mullock, S. J.

    1998-02-01

    The benefits of on-site analysis of environmental pollutants are well known, with such techniques increasing sample throughput and reducing the overall cost of pollution level monitoring. This article describes a transportable time-of-flight (TOF) mass spectrometer, based upon a converging, annular TOF (CAT) arrangement. The instrument, the transportable CAT or T-CAT is battery powered and self-contained. The vacuum chamber is never vented and is kept at a very low pressure, even during analysis. Sample gases are admitted to the mass spectrometer via a membrane inlet system. Data collection and analysis are accomplished via a portable PC. The T-CAT is capable of detection limits approaching those of more conventional, nonportable design. The device shows reasonable linearity over wide concentration ranges. Initial results indicate that the T-CAT will be capable of use in a wide range of applications, particularly for environmental monitoring. This article describes the features of the T-CAT, and presents initial results from the membrane inlet/T-CAT system.

  20. A real time scintillating fiber Time of Flight spectrometer for LINAC photoproduced neutrons

    NASA Astrophysics Data System (ADS)

    Maspero, M.; Berra, A.; Conti, V.; Giannini, G.; Ostinelli, A.; Prest, M.; Vallazza, E.

    2015-03-01

    The use of high-energy (> 8 MeV) LINear ACcelerators (LINACs) for medical cancer treatments causes the photoproduction of secondary neutrons, whose unwanted dose to the patient has to be calculated. The characterization of the neutron spectra is necessary to allow the dosimetric evaluation of the neutron beam contamination. The neutron spectrum in a hospital environment is usually measured with integrating detectors such as bubble dosimeters, Thermo Luminescent Dosimeters (TLDs) or Bonner Spheres, which integrate the information over a time interval and an energy one. This paper presents the development of a neutron spectrometer based on the Time of Flight (ToF) technique in order to perform a real time characterization of the neutron contamination. The detector measures the neutron spectrum exploiting the fact that the LINAC beams are pulsed and arranged in bunches with a rate of 100-300 Hz depending on the beam type and energy. The detector consists of boron loaded scintillating fibers readout by a MultiAnode PhotoMultiplier Tube (MAPMT). A detailed description of the detector and the acquisition system together with the results in terms of ToF spectra and number of neutrons with a Varian Clinac iX are presented.

  1. Development of a Portable Single Photon Ionization-Photoelectron Ionization Time-of-Flight Mass Spectrometer

    PubMed Central

    Huang, Yunguang; Li, Jinxu; Tang, Bin; Zhu, Liping; Hou, Keyong; Li, Haiyang

    2015-01-01

    A vacuum ultraviolet lamp based single photon ionization- (SPI-) photoelectron ionization (PEI) portable reflecting time-of-flight mass spectrometer (TOFMS) was designed for online monitoring gas samples. It has a dual mode ionization source: SPI for analyte with ionization energy (IE) below 10.6 eV and PEI for IE higher than 10.6 eV. Two kinds of sampling inlets, a capillary inlet and a membrane inlet, are utilized for high concentration and trace volatile organic compounds, respectively. A mass resolution of 1100 at m/z 64 has been obtained with a total size of 40 × 31 × 29 cm, the weight is 27 kg, and the power consumption is only 70 W. A mixture of benzene, toluene, and xylene (BTX), SO2, and discharging products of SF6 were used to test its performance, and the result showed that the limit of quantitation for BTX is as low as 5 ppbv (S/N = 10 : 1) with linear dynamic ranges greater than four orders of magnitude. The portable TOFMS was also evaluated by analyzing volatile organic compounds from wine and decomposition products of SF6 inside of a gas-insulated switchgear. PMID:26587023

  2. Improved streamlines and time-of-flight for streamline simulation on irregular grids

    NASA Astrophysics Data System (ADS)

    Hægland, H.; Dahle, H. K.; Eigestad, G. T.; Lie, K.-A.; Aavatsmark, I.

    2007-04-01

    Streamline methods have shown to be effective for reservoir simulation. For a regular grid, it is common to use the semi-analytical Pollock's method to obtain streamlines and time-of-flight coordinates (TOF). The usual way of handling irregular grids is by trilinear transformation of each grid cell to a unit cube together with a linear flux interpolation scaled by the Jacobian. The flux interpolation allows for fast integration of streamlines, but is inaccurate even for uniform flow. To improve the tracing accuracy, we introduce a new interpolation method, which we call corner-velocity interpolation. Instead of interpolating the velocity field based on discrete fluxes at cell edges, the new method interpolates directly from reconstructed point velocities given at the corner points in the grid. This allows for reproduction of uniform flow, and eliminates the influence of cell geometries on the velocity field. Using several numerical examples, we demonstrate that the new method is more accurate than the standard tracing methods.

  3. Simultaneous reconstruction of activity and attenuation in time-of-flight PET.

    PubMed

    Rezaei, Ahmadreza; Defrise, Michel; Bal, Girish; Michel, Christian; Conti, Maurizio; Watson, Charles; Nuyts, Johan

    2012-12-01

    In positron emission tomography (PET) and single photon emission tomography (SPECT), attenuation correction is necessary for quantitative reconstruction of the tracer distribution. Previously, several attempts have been made to estimate the attenuation coefficients from emission data only. These attempts had limited success, because the problem does not have a unique solution, and severe and persistent "cross-talk" between the estimated activity and attenuation distributions was observed. In this paper, we show that the availability of time-of-flight (TOF) information eliminates the cross-talk problem by destroying symmetries in the associated Fisher information matrix. We propose a maximum-a-posteriori reconstruction algorithm for jointly estimating the attenuation and activity distributions from TOF PET data. The performance of the algorithm is studied with 2-D simulations, and further illustrated with phantom experiments and with a patient scan. The estimated attenuation image is robust to noise, and does not suffer from the cross-talk that was observed in non-TOF PET. However, some constraining is still mandatory, because the TOF data determine the attenuation sinogram only up to a constant offset.

  4. Time-of-flight electron energy loss spectroscopy using TM110 deflection cavities.

    PubMed

    Verhoeven, W; van Rens, J F M; van Ninhuijs, M A W; Toonen, W F; Kieft, E R; Mutsaers, P H A; Luiten, O J

    2016-09-01

    We demonstrate the use of two TM110 resonant cavities to generate ultrashort electron pulses and subsequently measure electron energy losses in a time-of-flight type of setup. The method utilizes two synchronized microwave cavities separated by a drift space of 1.45 m. The setup has an energy resolution of 12 ± 2 eV FWHM at 30 keV, with an upper limit for the temporal resolution of 2.7 ± 0.4 ps. Both the time and energy resolution are currently limited by the brightness of the tungsten filament electron gun used. Through simulations, it is shown that an energy resolution of 0.95 eV and a temporal resolution of 110 fs can be achieved using an electron gun with a higher brightness. With this, a new method is provided for time-resolved electron spectroscopy without the need for elaborate laser setups or expensive magnetic spectrometers.

  5. Time-of-flight electron energy loss spectroscopy using TM110 deflection cavities

    PubMed Central

    Verhoeven, W.; van Rens, J. F. M.; van Ninhuijs, M. A. W.; Toonen, W. F.; Kieft, E. R.; Mutsaers, P. H. A.; Luiten, O. J.

    2016-01-01

    We demonstrate the use of two TM110 resonant cavities to generate ultrashort electron pulses and subsequently measure electron energy losses in a time-of-flight type of setup. The method utilizes two synchronized microwave cavities separated by a drift space of 1.45 m. The setup has an energy resolution of 12 ± 2 eV FWHM at 30 keV, with an upper limit for the temporal resolution of 2.7 ± 0.4 ps. Both the time and energy resolution are currently limited by the brightness of the tungsten filament electron gun used. Through simulations, it is shown that an energy resolution of 0.95 eV and a temporal resolution of 110 fs can be achieved using an electron gun with a higher brightness. With this, a new method is provided for time-resolved electron spectroscopy without the need for elaborate laser setups or expensive magnetic spectrometers. PMID:27704035

  6. Time-of-flight thermal flowrate sensor for lab-on-chip applications.

    PubMed

    Berthet, Helene; Jundt, Jacques; Durivault, Jerome; Mercier, Bruno; Angelescu, Dan

    2011-01-21

    We describe a thermal microflowrate sensor for measuring liquid flow velocity in microfluidic channels, which is capable of providing a highly accurate response independent of the thermal and physical properties of the working liquid. The sensor consists of a rectangular channel containing a heater and several temperature detectors microfabricated on suspended silicon bridges. Heat pulses created by the heater are advected downstream by the flow and are detected using the temperature detector bridges. By injecting a pseudo-stochastic thermal signal at the heater and performing a cross correlation between the detected and the injected signals, we can measure the single-pulse response of the system with excellent signal-to-noise ratio and hence deduce the thermal signal time-of-flight from heater to detector. Combining results from several detector bridges allows us to eliminate diffusion effects, and thus calculate the flow velocity with excellent accuracy and linearity over more than two orders of magnitude. The experimental results obtained with several test fluids closely agree with data from finite element analysis. We developed a phenomenological model which supports and explains the observed sensor response. Several fully functional sensor prototypes were built and characterized, proving the feasibility and providing a critical component to microfluidic lab-on-chip applications where accurate flow measurements are of importance.

  7. Depth Errors Analysis and Correction for Time-of-Flight (ToF) Cameras

    PubMed Central

    He, Ying; Liang, Bin; Zou, Yu; He, Jin; Yang, Jun

    2017-01-01

    Time-of-Flight (ToF) cameras, a technology which has developed rapidly in recent years, are 3D imaging sensors providing a depth image as well as an amplitude image with a high frame rate. As a ToF camera is limited by the imaging conditions and external environment, its captured data are always subject to certain errors. This paper analyzes the influence of typical external distractions including material, color, distance, lighting, etc. on the depth error of ToF cameras. Our experiments indicated that factors such as lighting, color, material, and distance could cause different influences on the depth error of ToF cameras. However, since the forms of errors are uncertain, it’s difficult to summarize them in a unified law. To further improve the measurement accuracy, this paper proposes an error correction method based on Particle Filter-Support Vector Machine (PF-SVM). Moreover, the experiment results showed that this method can effectively reduce the depth error of ToF cameras to 4.6 mm within its full measurement range (0.5–5 m). PMID:28067767

  8. Time-of-flight mass measurements for nuclear processes in neutron star crusts

    SciTech Connect

    Estrade, Alfredo; Matos, M.; Schatz, Hendrik; Amthor, A. M.; Bazin, D.; Beard, Mary; Becerril, A.; Brown, Edward; Elliot, T; Gade, A.; Galaviz, D.; George, S.; Gupta, Sanjib; Hix, William Raphael; Lau, Rita; Moeller, Peter; Pereira, J.; Portillo, M.; Rogers, A. M.; Shapira, Dan; Smith, E.; Stolz, A.; Wallace, M.; Wiescher, Michael

    2011-01-01

    The location of electron capture heat sources in the crust of accreting neutron stars depends on the masses of extremely neutron-rich nuclei. We present first results from a new implementation of the time-of-flight technique to measure nuclear masses of rare isotopes at the National Supercon- ducting Cyclotron Laboratory. The masses of 16 neutron-rich nuclei in the Sc Ni element range were determined simultaneously, improving the accuracy compared to previous data in 12 cases. The masses of 61V, 63Cr, 66Mn, and 74Ni were measured for the first time with mass excesses of 30.510(890) MeV, 35.280(650) MeV, 36.900(790) MeV, and 49.210(990) MeV, respectively. With the measurement of the 66Mn mass, the location of the two dominant heat sources in the outer crust of accreting neutron stars, which exhibit so called superbursts, is now experimentally constrained. We find that the location of the 66Fe 66Mn electron capture transition occurs sig- nificantly closer to the surface than previously assumed because our new experimental Q-value is 2.1 MeV smaller than predicted by the FRDM mass model. The results also provide new insights into the structure of neutron-rich nuclei around N = 40.

  9. Precise pulsed time-of-flight laser range finder for industrial distance measurements

    NASA Astrophysics Data System (ADS)

    Kilpelä, Ari; Pennala, Riku; Kostamovaara, Juha

    2001-04-01

    A pulsed time-of-flight laser range finder with a 1 GHz avalanche photo diode (APD) receiver and a laser pulser with ˜35 ps pulse width has been developed and tested. The receiver channel is constructed using a silicon ASIC chip and a commercially available silicon APD placed on a hybrid ceramic susbstrate. The laser pulser utilizes a single heterostructure laser operating in Q-switching mode. It is shown that the single-shot precision of the complete laser range finder is ˜2.1 mm (σ value) at best. The nonaccuracy in the distance range of 0.5-34.5 m was ˜±2 mm excluding errors caused by the statistical variations and long-term instability. The single-shot precision is clearly better than the single-shot precision of the earlier laser range finders with ˜100-200 MHz bandwidths. Also, two types of optics, coaxial and paraxial, were tested. The linearity of the coaxial optics was better, especially with a long (4 m) receiver fiber. Some possible applications of the laser range finder utilizing ps level pulses are, for example, fast three-dimensional vision in industrial environments and structure analysis of materials.

  10. In-home hierarchical posture classification with a time-of-flight 3D sensor.

    PubMed

    Diraco, Giovanni; Leone, Alessandro; Siciliano, Pietro

    2014-01-01

    A non-invasive technique for posture classification suitable to be used in several in-home scenarios is proposed and preliminary validation results are presented. 3D point cloud sequences were acquired using a single time-of-flight sensor working in a privacy preserving modality and they were processed with a low power embedded PC. In order to satisfy different application requirements (e.g. covered distance range, processing speed and discrimination capabilities), a twofold discrimination approach was investigated in which features were hierarchically arranged from coarse to fine by exploiting both topological and volumetric representations. The topological representation encoded the intrinsic topology of the body's shape using a skeleton-based structure, thus guaranteeing invariance to scale, rotations and postural changes and achieving a high level of detail with a moderate computational cost. On the other hand, using the volumetric representation features were described in terms of 3D cylindrical histograms working within a wider range of distances in a faster way and also guaranteeing good invariance properties. The discrimination capabilities were evaluated in four different real-home scenarios related with the fields of ambient assisted living and homecare, namely "dangerous event detection", "anomalous behaviour detection", "activities recognition" and "natural human-ambient interaction". For each mentioned scenario, the discrimination capabilities were evaluated in terms of invariance to viewpoint changes, representation capabilities and classification performance, achieving promising results. The two feature representation approaches exhibited complementary characteristics showing high reliability with classification rates greater than 97%.

  11. Fast fingerprinting of arson accelerants by proton transfer reaction time-of-flight mass spectrometry

    NASA Astrophysics Data System (ADS)

    Whyte, Christopher; Wyche, Kevin P.; Kholia, Mitesh; Ellis, Andrew M.; Monks, Paul S.

    2007-06-01

    Current techniques for the forensic analysis of fire debris as a means to detect the presence of arson accelerants normally use off-line sampling with the collection of accelerant vapours on activated charcoal strips and further pre-chemistry prior to analysis. An alternative method for the direct detection of arson accelerants that requires no sample pre-treatment is described here. The analysis uses proton transfer reaction mass spectrometry (PTR-MS), incorporating a time-of-flight mass spectrometer for rapid multichannel compound detection. It is demonstrated that using PTR-MS volatile organic compound (VOC) fingerprints of a given fire accelerant can be collected by simple head space analysis of accelerant burned materials. Using a set of the four most common arson accelerants and four common household building materials, characteristic VOC fingerprints are shown to provide successful identification of the accelerant used to burn each material. There is the potential to develop this methodology for the rapid screening of large numbers of samples.

  12. Acoustic tweezers via sub–time-of-flight regime surface acoustic waves

    PubMed Central

    Collins, David J.; Devendran, Citsabehsan; Ma, Zhichao; Ng, Jia Wei; Neild, Adrian; Ai, Ye

    2016-01-01

    Micrometer-scale acoustic waves are highly useful for refined optomechanical and acoustofluidic manipulation, where these fields are spatially localized along the transducer aperture but not along the acoustic propagation direction. In the case of acoustic tweezers, such a conventional acoustic standing wave results in particle and cell patterning across the entire width of a microfluidic channel, preventing selective trapping. We demonstrate the use of nanosecond-scale pulsed surface acoustic waves (SAWs) with a pulse period that is less than the time of flight between opposing transducers to generate localized time-averaged patterning regions while using conventional electrode structures. These nodal positions can be readily and arbitrarily positioned in two dimensions and within the patterning region itself through the imposition of pulse delays, frequency modulation, and phase shifts. This straightforward concept adds new spatial dimensions to which acoustic fields can be localized in SAW applications in a manner analogous to optical tweezers, including spatially selective acoustic tweezers and optical waveguides. PMID:27453940

  13. Bayesian Time-of-Flight for Realtime Shape, Illumination and Albedo.

    PubMed

    Adam, Amit; Dann, Christoph; Yair, Omer; Mazor, Shai; Nowozin, Sebastian

    2016-05-12

    We propose a computational model for shape, illumination and albedo inference in a pulsed time-of-flight (TOF) camera. In contrast to TOF cameras based on phase modulation, our camera enables general exposure profiles. This results in added flexibility and requires novel computational approaches. To address this challenge we propose a generative probabilistic model that accurately relates latent imaging conditions to observed camera responses. While principled, realtime inference in the model turns out to be infeasible, and we propose to employ efficient non-parametric regression trees to approximate the model outputs. As a result we are able to provide, for each pixel, at video frame rate, estimates and uncertainty for depth, effective albedo, and ambient light intensity. These results we present are state-of-the-art in depth imaging. The flexibility of our approach allows us to easily enrich our generative model. We demonstrate this by extending the original single-path model to a two-path model, capable of describing some multipath effects. The new model is seamlessly integrated in the system at no additional computational cost. Our work also addresses the important question of optimal exposure design in pulsed TOF systems. Finally, for benchmark purposes and to obtain realistic empirical priors of multipath and insights into this phenomena, we propose a physically accurate simulation of multipath phenomena.

  14. Rapid identification of triphenylmethane dyes by ion mobility time-of-flight mass spectrometry.

    PubMed

    Sysoev, Alexey A; Poteshin, Sergey S; Chernyshev, Denis M; Sysoev, Alexander A

    2016-01-01

    An ion mobility time-of-flight mass spectrometry (IM-TOFMS)-based method has been preliminarily investigated for the identification of triphenylmethane ballpoint pen dyes on paper. The dyes were sampled from one-year-old ballpoint pen ink entries. The entries were written on paper documents stored in the dark in a bookcase. Sample solutions were prepared by extraction of dyes in a vial. Basic violet 2, Methyl violet 6B, Methyl violet 2B and Crystal violet were characterized by IM-TOFMS. Since the ballpoint ink dyes contain ionic compounds, the studied compounds were expected to form stable peaks in the atmospheric pressure drift tube ion mobility spectrometry, and this was experimentally verified. The studied dyes produce [M - Cl](+) ions in electrospray and form stable individual mass-selective reduced mobility peaks. The values of the characteristic reduced mobility are: 1.187 cm(2)/(V·s) for Basic violet 2 (m/z 330.20), 1.165 cm(2)/(V·s) for Methyl violet 6B (m/z 344.21), 1.156 cm(2)/(V·s) for Methyl violet 2B (m/z 358.23), 1.123 cm(2)/(V·s) for Crystal violet (m/z 372.24). IM-TOFMS is expected to be a promising tool for fast and reliable analysis of dyes in complex matrixes.

  15. Laser desorption time-of-flight mass spectrometry of vacuum UV photo-processed methanol ice

    NASA Astrophysics Data System (ADS)

    Paardekooper, D. M.; Bossa, J.-B.; Linnartz, H.

    2016-07-01

    Context. Methanol in the interstellar medium mainly forms upon sequential hydrogenation of solid CO. With typical abundances of up to 15% (with respect to water) it is an important constituent of interstellar ices where it is considered as a precursor in the formation of large and complex organic molecules (COMs), e.g. upon vacuum UV (VUV) photo-processing or exposure to cosmic rays. Aims: This study aims at detecting novel complex organic molecules formed during the VUV photo-processing of methanol ice in the laboratory using a technique more sensitive than regular surface diagnostic tools. In addition, the formation kinetics of the main photo-products of methanol are unravelled for an astronomically relevant temperature (20 K) and radiation dose. Methods: The VUV photo-processing of CH3OH ice is studied by applying laser desorption post-ionisation time-of-flight mass spectrometry (LDPI TOF-MS), and analysed by combining molecule-specific fragmentation and desorption features. Results: The mass spectra correspond to fragment ions originating from a number of previously recorded molecules and from new COMs, such as the series (CO)xH, with x = 3 and y < 3x-1, to which prebiotic glycerin belongs. The formation of these large COMs has not been reported in earlier photolysis studies and suggests that such complex species may form in the solid state under interstellar conditions.

  16. Neutron time-of-flight spectroscopy measurement using a waveform digitizer

    NASA Astrophysics Data System (ADS)

    Liu, Long-Xiang; Wang, Hong-Wei; Ma, Yu-Gang; Cao, Xi-Guang; Cai, Xiang-Zhou; Chen, Jin-Gen; Zhang, Gui-Lin; Han, Jian-Long; Zhang, Guo-Qiang; Hu, Ji-Feng; Wang, Xiao-He

    2016-05-01

    The photoneutron source (PNS, phase 1), an electron linear accelerator (linac)-based pulsed neutron facility that uses the time-of-flight (TOF) technique, was constructed for the acquisition of nuclear data from the Thorium Molten Salt Reactor (TMSR) at the Shanghai Institute of Applied Physics (SINAP). The neutron detector signal used for TOF calculation, with information on the pulse arrival time, pulse shape, and pulse height, was recorded by using a waveform digitizer (WFD). By using the pulse height and pulse-shape discrimination (PSD) analysis to identify neutrons and γ-rays, the neutron TOF spectrum was obtained by employing a simple electronic design, and a new WFD-based DAQ system was developed and tested in this commissioning experiment. The DAQ system developed is characterized by a very high efficiency with respect to millisecond neutron TOF spectroscopy. Supported by Strategic Priority Research Program of the Chinese Academy of Science(TMSR) (XDA02010100), National Natural Science Foundation of China(NSFC)(11475245,No.11305239), Shanghai Key Laboratory of Particle Physics and Cosmology (11DZ2260700)

  17. Diting: A polarized time-of-flight neutron reflectometer at CMRR reactor in China

    NASA Astrophysics Data System (ADS)

    Li, Xinxi; Huang, Chaoqiang; Wang, Yan; Chen, Bo; Sun, Guang'ai; Liu, Yaoguang; Gong, Jian; Kang, Wu; Liu, Hangang

    2016-11-01

    A new time-of-flight neutron reflectometer with a polarization option is developed and tested at the Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang, China. Its scattering geometry is horizontal. The constructed neutron reflectometer is a multipurpose instrument that can be used for the characterization of a stratified microstructure and hidden interfaces of solid thin films. Diting is designed for both magnetic and nonmagnetic multi-layer thin films. Spin polarization and analysis are achieved by transmission magnetized supermirrors. The sample unit is equipped with an electromagnet, which can provide a vertical magnetic field range of 0-1.2 tesla. The available neutron beam is a white beam with wavelength range of 0.15-1.25 nm, which can be cut into different wavelength resolution neutron pulses by a four-disk chopper. A two-dimensional position-sensitive detector is employed to count the specular and off-specular reflected neutron beam. A minimum reflectivity of 10-6 is measured on this instrument.

  18. Lattice thermal expansion effects in pure and doped cordierite by time-of-flight neutron diffraction

    SciTech Connect

    Predecki, P.K.; Haas, J.; Faber, J. Jr.; Hitterman, R.L.

    1985-10-01

    The thermal expansion behavior of pure, Ge-doped and Li-doped hexagonal cordierites with respective compositions: 2Mg0 2Al2O3 5SiO2, 2Mg0 2Al2O3 4SiO2 GeO2, and 2Mg0 (2+x)Al2O3 (5-2x)SiO2 xLi2O with x = .174, was investigated using time-of-flight neutron powder diffraction at temperatures from 22 to 750C in vacuum. The data were refined in space group P6/mcc using the Rietveld method. The lattice thermal expansion curves of all 3 samples were quite similar. The negative c axis expansion is asociated with (1) displacement of the T2 cations generally toward the c axis channels and (2) changes in the distortion of the coupled T1/M tetrahedra/octahedra in the structure. Both contributions were present in all 3 samples but the first was more dominant in the Ge doped sample. The nature and origin of the distortions in T1 and M are discussed.

  19. Impulse responses of visible phototubes used in National Ignition Facility neutron time of flight diagnostics.

    PubMed

    Datte, P S; Eckart, M; Moore, A S; Thompson, W; Vergel de Dios, G

    2016-11-01

    Neutron-induced visible scintillation in neutron time of flight (NToF) diagnostics at the National Ignition Facility (NIF) is measured with 40 mm single stage micro-channel plate photomultipliers and a 40 mm vacuum photodiode, outside the neutron line of sight. In NIF experiments with 14 MeV neutron yields above Y > 10 × 10(15) these tubes are configured to deliver of order 1 nC of charge in the nominally 5 ns NToF into a 50 Ω load. We have examined a number of 40 mm tubes manufactured by Photek Ltd. of St. Leonards on Sea, UK, to determine possible changes in the instrument impulse response as a function of signal charge delivered in 1 ns. Precision NToF measurements at approximately 20 m require that we characterize changes in the impulse response moments to <40 ps for the first central moment and ∼2% rms for the square root of the second central moment with ∼500 ps value. Detailed results are presented for three different diode configurations.

  20. Probing the oligomeric structure of an enzyme by electrospray ionization time-of-flight mass spectrometry.

    PubMed

    Fitzgerald, M C; Chernushevich, I; Standing, K G; Whitman, C P; Kent, S B

    1996-07-09

    Electrospray ionization time-of-flight (ESI-TOF) mass spectrometry was used to study the quaternary structure of 4-oxalocrotonate tautomerase (EC 5.3.2; 4OT), and four analogues prepared by total chemical synthesis. Wild-type 4OT is a hexamer of 62 amino acid subunits and contains no cysteine residues. The analogues were: (desPro1)4OT, a truncated construct in which Pro1 was deleted; (Cpc1)4OT in which Pro1 was replaced with cyclopentane carboxylate; a derivative [Met(O)45]4OT in which Met45 was oxidized to the sulfoxide; and an analogue (Nle45)4OT in which Met45 was replaced with norleucine. ESI of (Nle45)4OT, (Cpc1)4OT, and 4OT from solution conditions under which the native enzyme was fully active (5 mM ammonium bicarbonate buffer, pH 7.5) gave the intact hexamer as the major species detected by TOF mass spectrometry. In contrast, analysis of [Met(O)45]4OT and (desPro1)4OT under similar conditions yielded predominantly monomer ions. The ESI-TOF measurements were consistent with structural data obtained from circular dichroism spectroscopy. In the context of kinetic data collected for 4OT and these analogues, ESI-TOF mass spectrometry also provided important evidence for the structural and mechanistic significance of the catalytically important Pro1 residue in 4OT.

  1. Higher-Pressure Ion Funnel Trap Interface for Orthogonal Time-of-Flight Mass Spectrometry

    PubMed Central

    Ibrahim, Yehia; Belov, Mikhail E.; Tolmachev, Aleksey V.; Prior, David C.; Smith, Richard D.

    2008-01-01

    A combined electrodynamic ion funnel and ion trap coupled to an orthogonal acceleration (oa)-time-of-flight mass spectrometer (oa-TOF MS) was developed and characterized. The ion trap was incorporated through the use of added terminal electrodynamic ion funnel electrodes enabling control over the axial DC gradient in the trap section. The ion trap operates efficiently at a pressure of 1 Torr, and measurements indicate a maximum charge capacity of ~3×107 charges. An order of magnitude increase in sensitivity was observed in the analysis of low concentration peptides mixtures with oa-TOF MS in the trapping mode as compared to the continuous regime. A signal increase in the trapping mode was accompanied by reduction in the background chemical noise, due to more efficient desolvation of e.g., solvent related clusters. Controlling the ion trap ejection time was found to result in efficient removal of singly charged species and improving signal-to-noise ratio (S/N) for the multiply charged analytes. PMID:17850113

  2. Probing the oligomeric structure of an enzyme by electrospray ionization time-of-flight mass spectrometry.

    PubMed Central

    Fitzgerald, M C; Chernushevich, I; Standing, K G; Whitman, C P; Kent, S B

    1996-01-01

    Electrospray ionization time-of-flight (ESI-TOF) mass spectrometry was used to study the quaternary structure of 4-oxalocrotonate tautomerase (EC 5.3.2; 4OT), and four analogues prepared by total chemical synthesis. Wild-type 4OT is a hexamer of 62 amino acid subunits and contains no cysteine residues. The analogues were: (desPro1)4OT, a truncated construct in which Pro1 was deleted; (Cpc1)4OT in which Pro1 was replaced with cyclopentane carboxylate; a derivative [Met(O)45]4OT in which Met45 was oxidized to the sulfoxide; and an analogue (Nle45)4OT in which Met45 was replaced with norleucine. ESI of (Nle45)4OT, (Cpc1)4OT, and 4OT from solution conditions under which the native enzyme was fully active (5 mM ammonium bicarbonate buffer, pH 7.5) gave the intact hexamer as the major species detected by TOF mass spectrometry. In contrast, analysis of [Met(O)45]4OT and (desPro1)4OT under similar conditions yielded predominantly monomer ions. The ESI-TOF measurements were consistent with structural data obtained from circular dichroism spectroscopy. In the context of kinetic data collected for 4OT and these analogues, ESI-TOF mass spectrometry also provided important evidence for the structural and mechanistic significance of the catalytically important Pro1 residue in 4OT. PMID:8692908

  3. Charge state separation for protein applications using a quadrupole time-of-flight mass spectrometer.

    PubMed

    Chernushevich, I V; Fell, L M; Bloomfield, N; Metalnikov, P S; Loboda, A V

    2003-01-01

    A novel method for separating ions according to their charge state using a quadrupole time-of-flight mass spectrometer is presented. The benefits of charge state separation are particularly apparent in protein identification applications at low femtomole concentration levels, where in conventional TOF MS spectra peptide ions are often lost in a sea of chemical noise. When doubly and triply charged tryptic peptide ions need to be filtered from singly charged background ions, the latter are suppressed by two to three orders of magnitude, while from 10-50% of multiply charged ions remain. The suppression of chemical noise reduces the need for chromatography and can make this experimental approach the electrospray equivalent of conventional MALDI peptide maps. If unambiguous identification cannot be achieved, MS/MS experiments are performed on the precursor ions identified through charge separation, while the previously described Q2-trapping duty cycle enhancement is tuned for approximately 1.4 of the precursor m/z to enhance intensities of ions with m/z values above that of the precursor. The resulting product ion spectra contain few fragments of impurities and provide quick and unambiguous identification through database search. The multiple charge separation technique requires minimal tuning and may become a useful tool for analysis of complex mixtures.

  4. Novel time-of-flight spectrometer for the analysis of positron annihilation induced Auger electrons

    NASA Astrophysics Data System (ADS)

    Hugenschmidt, Christoph; Legl, Stefan

    2006-10-01

    Positron annihilation induced Auger-electron spectroscopy (PAES) has several advantages over conventional Auger-electron spectroscopy such as extremely high surface sensitivity and outstanding signal-to-noise ratio at the Auger-transition energy. In order to benefit from these prominent features a low-energy positron beam of high intensity is required for surface sensitive PAES studies. In addition, an electron energy analyzer is required, which efficiently detects the Auger electrons with acceptable energy resolution. For this reason a novel time-of-flight (TOF) spectrometer has been developed at the intense positron source NEPOMUC that allows PAES studies within short measurement time. This TOF-PAES setup combines a trochoidal filter and a flight tube in a Faraday cage in order to achieve an improved energy resolution of about 1eV at high electron energies up to E ≈1000eV. The electron flight time is the time between the annihilation radiation at the sample and when the electron hits a microchannel plate detector at the end of the flight tube.

  5. Development of position-sensitive time-of-flight spectrometer for fission fragment research

    DOE PAGES

    Arnold, C. W.; Tovesson, F.; Meierbachtol, K.; ...

    2014-07-09

    A position-sensitive, high-resolution time-of-flight detector for fission fragments has been developed. The SPectrometer for Ion DEtermination in fission Research (SPIDER) is a 2E–2v spectrometer designed to measure the mass of light fission fragments to a single mass unit. The time pick-off detector pairs to be used in SPIDER have been tested with α-particles from 229Th and its decay chain and α-particles and spontaneous fission fragments from 252Cf. Each detector module is comprised of thin electron conversion foil, electrostatic mirror, microchannel plates, and delay-line anodes. Particle trajectories on the order of 700 mm are determined accurately to within 0.7 mm. Flightmore » times were measured with 250 ps resolution FWHM. Computed particle velocities are accurate to within 0.06 mm/ns corresponding to a precision of 0.5%. As a result, an ionization chamber capable of 400 keV energy resolution coupled with the velocity measurements described here will pave the way for modestly efficient measurements of light fission fragments with unit mass resolution.« less

  6. Analysis of lung surfactant model systems with time-of-flight secondary ion mass spectrometry.

    PubMed Central

    Bourdos, N; Kollmer, F; Benninghoven, A; Ross, M; Sieber, M; Galla, H J

    2000-01-01

    An often-used model lung surfactant containing dipalmitoylphosphatidylcholine (DPPC), dipalmitoylphosphatidylglycerol (DPPG), and the surfactant protein C (SP-C) was analyzed as Langmuir-Blodgett film by spatially resolved time-of-flight secondary ion mass spectrometry (TOF-SIMS) to directly visualize the formation and composition of domains. Binary lipid and lipid/SP-C systems were probed for comparison. TOF-SIMS spectra revealed positive secondary ions (SI) characteristic for DPPC and SP-C, but not for DPPG. SI mapping results in images with domain structures in DPPC/DPPG and DPPG/SP-C, but not in DPPC/SP-C films. We are able to distinguish between the fluid and condensed areas probably due to a matrix effect. These findings correspond with other imaging techniques, fluorescence light microscopy (FLM), scanning force microscopy (SFM), and silver decoration. The ternary mixture DPPC/DPPG/SP-C transferred from the collapse region exhibited SP-C-rich domains surrounding pure lipid areas. The results obtained are in full accordance with our earlier SFM picture of layered protrusions that serve as a compressed reservoir for surfactant material during expansion. Our study demonstrates once more that SP-C plays a unique role in the respiration process. PMID:10866961

  7. Highly miniaturized laser ablation time-of-flight mass spectrometer for a planetary rover

    NASA Astrophysics Data System (ADS)

    Rohner, Urs; Whitby, James A.; Wurz, Peter; Barabash, Stas

    2004-05-01

    We report the development and testing of a highly miniaturized mass spectrometer and ion source intended to be deployed on an airless planetary surface to measure the elemental and isotopic composition of solids, e.g., rocks and soils. Our design concentrates at this stage on the proposed BepiColombo mission to the planet Mercury. The mass analyzer is a novel combination of an electrostatic analyzer and a reflectron time-of-flight design. The ion source utilizes a laser induced plasma, which is directly coupled into the mass analyzer. Laser ablation gives high spatial resolution and avoids the need for sample preparation. Our prototype instrument has a demonstrated mass resolution m/Δm full width at half maximum in excess of 180 and a predicted dynamic range of better than five orders of magnitude. We estimate that a flight instrument would have a mass of 280 g (including laser and all electronics), a volume of 84 cm3, and could operate on 3 W power.

  8. Measuring Time-of-Flight in an Ultrasonic LPS System Using Generalized Cross-Correlation

    PubMed Central

    Villladangos, José Manuel; Ureña, Jesús; García, Juan Jesús; Mazo, Manuel; Hernández, Álvaro; Jiménez, Ana; Ruíz, Daniel; De Marziani, Carlos

    2011-01-01

    In this article, a time-of-flight detection technique in the frequency domain is described for an ultrasonic Local Positioning System (LPS) based on encoded beacons. Beacon transmissions have been synchronized and become simultaneous by means of the DS-CDMA (Direct-Sequence Code Division Multiple Access) technique. Every beacon has been associated to a 255-bit Kasami code. The detection of signal arrival instant at the receiver, from which the distance to each beacon can be obtained, is based on the application of the Generalized Cross-Correlation (GCC), by using the cross-spectral density between the received signal and the sequence to be detected. Prior filtering to enhance the frequency components around the carrier frequency (40 kHz) has improved estimations when obtaining the correlation function maximum, which implies an improvement in distance measurement precision. Positioning has been achieved by using hyperbolic trilateration, based on the Time Differences of Arrival (TDOA) between a reference beacon and the others. PMID:22346645

  9. Continuously moving table time-of-flight angiography of the peripheral veins.

    PubMed

    Huff, Sandra; Honal, Matthias; Baumann, Tobias; Hennig, Jürgen; Markl, Michael; Ludwig, Ute

    2010-05-01

    Time-of-flight (TOF) MR angiography allows for noninvasive vessel imaging. To overcome the limited volumetric coverage of standard TOF techniques, the aim of this study was to investigate the combination of TOF and continuously moving table (CMT) acquisitions for peripheral vein imaging based on image subtraction. Two acquisition strategies are presented: a simple two-step method based on 2-fold CMT acquisition and an advanced one-step method requiring only one continuous scan. Image quality of both CMT TOF techniques was evaluated by semiquantitative image grading and by signal-to-noise ratio and contrast-to-noise ratio analysis for veins of the upper and lower leg in 10 healthy volunteers. Results were compared to a standard stationary two-dimensional (2D) TOF multistation acquisition. Image grading revealed good image quality for both CMT TOF methods, thereby confirming the feasibility of axial 2D CMT TOF to assess the veins of the lower extremities during a single scan. Quantitative evaluation showed no significant difference in signal-to-noise ratio and contrast-to-noise ratio compared to the stationary experiment. Additional measurements in three patients with postthrombotic changes and varicosities demonstrated the clinical applicability of the presented methods. CMT TOF provides promising results and permits the detection of various pathologic changes of the venous system.

  10. Intracranial aneurysms: Diagnostics accuracy of three-dimensional, fourier transform, time-of-flight MR angiography

    SciTech Connect

    Korogi, Yukunori; Takahashi, Mutsumasa; Mabuchi, Nobuhisa; Miki, Hitoshi; Fujiwara, Satoru; Horikawa, Yoshiharu; Nakagawa, Toshio; O`Uchi, Toshihiro; Watabe, Tsuneya; Shiga, Hayao

    1994-10-01

    To assess the accuracy of three-dimensional, Fourier transform, time-of-flight magnetic resonance (MR) angiography in the identification of intracranial aneurysms. MR angiograms of 126 patients (59 male and 67 female patients, aged 12-77 years) with various intracranial vascular lesions were evaluated. Seventy-eight aneurysms, including 60 less than 5 mm in diameter, in 61 patients were depicted at conventional angiography. Eight projection images, as well as one axial collapsed MR angiogram obtained with a maximum-intensity projection algorithm, were used for evaluation. Sensitivity for the five observers ranged from 58% to 68% (mean, 63%). Higher sensitivity was achieved for anterior communicating and middle cerebral artery aneurysms, while that for internal carotid artery aneurysms was poor. Sensitivities for small and medium aneurysms ranged from 50% to 60% (mean, 56%) and from 77% to 94% (mean, 85%), respectively. MR angiography can depict intracranial aneurysms 5 mm or larger with good accuracy but is less useful for the identification of smaller aneurysms. 12 refs., 5 figs., 5 tabs.

  11. Development of high-rate MRPCs for high resolution time-of-flight systems

    NASA Astrophysics Data System (ADS)

    Wang, Jingbo; Wang, Yi; Gonzalez-Diaz, D.; Chen, Huangshan; Fan, Xingming; Li, Yuanjing; Cheng, Jianping; Kaspar, Marcus; Kotte, Roland; Laso Garcia, Alejandro; Naumann, Lothar; Stach, Daniel; Wendisch, Christian; Wüstenfeld, Jörn

    2013-06-01

    We show how the high charged-particle flux (1-20 kHz/cm2) expected over the 150 m2 large time-of-flight wall of the future Compressed Baryonic Matter experiment (CBM) at FAIR can be realistically handled with Multi-gap Resistive Plate Chambers (MRPCs). This crucial 100-fold increase of the chamber rate capability, as compared to that of standard MRPCs presently employed in experiments resorting to sub-100 ps timing, has been achieved thanks to the development of a new type of low-resistive doped glass. Following the encouraging results previously obtained with small counters, two types of modules (active area: ˜150 cm2) have been built at Tsinghua University with the new material. The measurements conveyed in this work, obtained with a quasi- minimum ionizing electron beam (γβ≥3), prove their suitability as the building blocks of the present hadron-identification concept of the CBM experiment. Namely, they provide a time resolution better than 80 ps and an efficiency above 90% at a particle flux well in excess of 20 kHz/cm2 (up to 35-60 kHz/cm2), being at the core of a modular concept that is easily scalable. Recent measurements of the electrical and mechanical properties of this new material, together with its long-term behavior, are shortly summarized.

  12. Isobar Separation in a Multiple-Reflection Time-of-Flight Mass Spectrometer by Mass-Selective Re-Trapping

    NASA Astrophysics Data System (ADS)

    Dickel, Timo; Plaß, Wolfgang R.; Lippert, Wayne; Lang, Johannes; Yavor, Mikhail I.; Geissel, Hans; Scheidenberger, Christoph

    2017-03-01

    A novel method for (ultra-)high-resolution spatial mass separation in time-of-flight mass spectrometers is presented. Ions are injected into a time-of-flight analyzer from a radio frequency (rf) trap, dispersed in time-of-flight according to their mass-to-charge ratios and then re-trapped dynamically in the same rf trap. This re-trapping technique is highly mass-selective and after sufficiently long flight times can provide even isobaric separation. A theoretical treatment of the method is presented and the conditions for optimum performance of the method are derived. The method has been implemented in a multiple-reflection time-of-flight mass spectrometer and mass separation powers (FWHM) in excess of 70,000, and re-trapping efficiencies of up to 35% have been obtained for the protonated molecular ion of caffeine. The isobars glutamine and lysine (relative mass difference of 1/4000) have been separated after a flight time of 0.2 ms only. Higher mass separation powers can be achieved using longer flight times. The method will have important applications, including isobar separation in nuclear physics and (ultra-)high-resolution precursor ion selection in multiple-stage tandem mass spectrometry.

  13. Laser photoionization time-of-flight mass spectrometry of nitrated polycyclic aromatic hydrocarbons and nitrated heterocyclic compounds. Master's thesis

    SciTech Connect

    Noyes, R.A.

    1993-01-01

    Partial Contents: Laser Desorption-Laser Photoionization Time-of-Flight Mass Spectrometry; Basic Principles of TOFMS; Factors Affecting Flight Time; Source of Broadening; Laser Desorption; Theory of Multiphoton Ionization: Application to Mass Spectrometry; Quantum Theory of MPI; Time-Dependent Perturbation Theory; Time-Dependent Coefficients; Probability of a Two-Photon Process; and Attributes of R2PI.

  14. Isobar Separation in a Multiple-Reflection Time-of-Flight Mass Spectrometer by Mass-Selective Re-Trapping.

    PubMed

    Dickel, Timo; Plaß, Wolfgang R; Lippert, Wayne; Lang, Johannes; Yavor, Mikhail I; Geissel, Hans; Scheidenberger, Christoph

    2017-03-15

    A novel method for (ultra-)high-resolution spatial mass separation in time-of-flight mass spectrometers is presented. Ions are injected into a time-of-flight analyzer from a radio frequency (rf) trap, dispersed in time-of-flight according to their mass-to-charge ratios and then re-trapped dynamically in the same rf trap. This re-trapping technique is highly mass-selective and after sufficiently long flight times can provide even isobaric separation. A theoretical treatment of the method is presented and the conditions for optimum performance of the method are derived. The method has been implemented in a multiple-reflection time-of-flight mass spectrometer and mass separation powers (FWHM) in excess of 70,000, and re-trapping efficiencies of up to 35% have been obtained for the protonated molecular ion of caffeine. The isobars glutamine and lysine (relative mass difference of 1/4000) have been separated after a flight time of 0.2 ms only. Higher mass separation powers can be achieved using longer flight times. The method will have important applications, including isobar separation in nuclear physics and (ultra-)high-resolution precursor ion selection in multiple-stage tandem mass spectrometry. Graphical Abstract ᅟ.

  15. Diamond detectors for time-of-flight measurements in laser-generated plasmas

    NASA Astrophysics Data System (ADS)

    Torrisi, L.; Margarone, D.; Milani, E.; Verona-Rinati, G.; Prestopino, G.; Tuvè, C.; Potenza, R.; Láska, L.; Krása, J.; Ullschmied, J.

    CVD mono-crystalline diamond thin films deposited on a doped diamond and aluminum backing were employed as detectors of the radiation emitted from the laser-generated plasma. Laser-matter interactions were obtained by the use of an Nd:Yag repetitive laser at INFN-LNS in Catania operating at 1010 W/cm2 pulse intensity, and a high-power iodine PALS laser in Prague operating at 1015 W/cm2 pulse intensity. Plasmas were obtained by ablating Al, Ta, Au, and CF2 bulk targets. Plasma characterization was carried out using diamond detectors and ion collectors placed at different distances and angles in relation to the position of the ablated target. Photons, electrons, and ions hitting the sensible volume of the detector generate electronhole pairs (loosing 13 eV for a pair), resulting in an arising of the voltage signal at the device electrodes, which is proportional to the deposited energy. Diamond detectors can measure UV, X-rays, electrons, and ions. The time-of-flight (TOF) technique was exploited to separate photon, electron, and particle contributions. Because of the high gap of the diamond band structure (5.48 eV), the detectors are blind to visible and IR light from the plasma, which results in very low background current. The TOF diamond spectra were compared with traditional ion collector spectra using the experimental data obtained from the experiments conducted at the Catania and Prague laboratories. The results indicate that the ion energy resolution of the employed diamond detectors is high and that the fast electrons can be detected from a deconvolution procedure applied to the fast photo-peak. Information about the mean energy of soft X-rays could be obtained by analyzing the fast contribute of the spectra acquired by using different absorber films.

  16. An FPGA Wave Union TDC for Time-of-Flight Applications

    SciTech Connect

    Wu, J.; /Fermilab

    2009-01-01

    An 18-channel time-of-flight (TOF) grade time-to-digit converter (TDC) has been implemented in a low cost FPGA device. The TDC has the following unique features. (1) The time recording structures of the TDC is based on the 'wave union TDC' we developed in our previous work. A leading edge of the input hit launches a bit pattern, or wave union into the delay chain-register array structure which yields two usable measurements. The two measurements effectively sub-divide timing bins for each other especially the 'ultra-wide bins' caused by the FPGA logic array block (LAB) structure and improves measurement precision both in terms of maximum bin width and RMS resolution. A coarser measurement on input signal trailing edge is also provided for time-over-threshold (TOT) applications. (2) The TDC supports advanced timing reference distribution schemes that are superior to conventional common start/stop schemes. The TDC has 16 regular measurement channels plus two channels for timing reference. The timing reference is established with multiple measurements rather than single shot common start/stop. An advanced scheme, the mean-timing approach even eliminates needs of high quality timing distribution media. (3) The ASIC-like encapsulation of the FPGA TDC significantly shorten the learning curve for potential users while maintain certain flexibility for various applications. Necessary digital post-processing functions including semicontinuous automatic calibration, data buffer, data link jam prevention logic etc. are integrated into the firmware to provide a turn-key solution for users.

  17. Time of flight emission spectroscopy of laser produced nickel plasma: Short-pulse and ultrafast excitations

    SciTech Connect

    Smijesh, N.; Chandrasekharan, K.; Joshi, Jagdish C.; Philip, Reji

    2014-07-07

    We report the experimental investigation and comparison of the temporal features of short-pulse (7 ns) and ultrafast (100 fs) laser produced plasmas generated from a solid nickel target, expanding into a nitrogen background. When the ambient pressure is varied in a large range of 10⁻⁶Torr to 10²Torr, the plume intensity is found to increase rapidly as the pressure crosses 1 Torr. Time of flight (TOF) spectroscopy of emission from neutral nickel (Ni I) at 361.9 nm (3d⁹(²D) 4p → 3d⁹(²D) 4s transition) reveals two peaks (fast and slow species) in short-pulse excitation and a single peak in ultrafast excitation. The fast and slow peaks represent recombined neutrals and un-ionized neutrals, respectively. TOF emission from singly ionized nickel (Ni II) studied using the 428.5 nm (3p⁶3d⁸(³P) 4s→ 3p⁶3d⁹ 4s) transition shows only a single peak for either excitation. Velocities of the neutral and ionic species are determined from TOF measurements carried out at different positions (i.e., at distances of 2 mm and 4 mm, respectively, from the target surface) on the plume axis. Measured velocities indicate acceleration of neutrals and ions, which is caused by the Coulomb pull of the electrons enveloping the plume front in the case of ultrafast excitation. Both Coulomb pull and laser-plasma interaction contribute to the acceleration in the case of short-pulse excitation. These investigations provide new information on the pressure dependent temporal behavior of nickel plasmas produced by short-pulse and ultrafast laser pulses, which have potential uses in applications such as pulsed laser deposition and laser-induced nanoparticle generation.

  18. Time-of-flight secondary neutral & ion mass spectrometry using swift heavy ions

    NASA Astrophysics Data System (ADS)

    Breuer, L.; Meinerzhagen, F.; Bender, M.; Severin, D.; Wucher, A.

    2015-12-01

    We report on a new time-of-flight (TOF) spectrometer designed to investigate sputtering phenomena induced by swift heavy ions in the electronic stopping regime. In this experiment, particular emphasis is put on the detection of secondary ions along with their emitted neutral counterparts in order to examine the ionization efficiency of the sputtered material. For the detection of neutral species, the system is equipped with a pulsed VUV laser for post-ionization of sputtered neutral atoms and molecules via single photon ionization at a wavelength of 157 nm (corresponding to 7.9 eV photon energy). For alignment purposes and in order to facilitate comparison to nuclear sputtering conditions, the system also includes a 5 keV Ar+ ion beam directed to the same sample area. The instrument has been added to the M1-branch beam line at the German accelerator facility in Darmstadt (GSI) and was tested with 4.8 MeV/u Au26+ ions impinging onto various samples including metals, salts and organic films. It is found that secondary ion and neutral spectra obtained under both bombardment conditions can be acquired in an interleaved manner throughout a single accelerator pulse cycle, thus making efficient use of valuable beam time. In addition, the keV ion beam can be intermittently switched to dc mode between subsequent data acquisition windows and accelerator pulses in order to ensure reproducible surface conditions. For the case of a dynamically sputter cleaned metal surface, comparison of secondary ion and neutral signals obtained under otherwise identical instrumental conditions reveals a nearly identical ionization probability of atoms emitted under electronic and nuclear sputtering conditions.

  19. SU-E-J-184: Stereo Time-Of-Flight System for Patient Positioning in Radiotherapy

    SciTech Connect

    Wentz, T; Gilles, M; Visvikis, D; Le Fur, E; Pradier, O

    2014-06-01

    Purpose: The objective of this work is to test the advantage of using the surface acquired by two stereo Time-of-Flight (ToF) cameras in comparison of the use of one camera only for patient positioning in radiotherapy. Methods: A first step consisted on validating the use of a stereo ToFcamera system for positioning management of a phantom mounted on a linear actuator producing very accurate and repeatable displacements. The displacements between two positions were computed from the surface point cloud acquired by either one or two cameras thanks to an iterative closest point algorithm. A second step consisted on determining the displacements on patient datasets, with two cameras fixed on the ceiling of the radiotherapy room. Measurements were done first on voluntary subject with fixed translations, then on patients during the normal clinical radiotherapy routine. Results: The phantom tests showed a major improvement in lateral and depth axis for motions above 10 mm when using the stereo-system instead of a unique camera (Fig1). Patient measurements validate these results with a mean real and measured displacement differences in the depth direction of 1.5 mm when using one camera and 0.9 mm when using two cameras (Fig2). In the lateral direction, a mean difference of 1 mm was obtained by the stereo-system instead of 3.2 mm. Along the longitudinal axis mean differences of 5.4 and 3.4 mm with one and two cameras respectively were noticed but these measurements were still inaccurate and globally underestimated in this direction as in the literature. Similar results were also found for patient subjects with a mean difference reduction of 35%, 7%, and 25% for the lateral, depth, and longitudinal displacement with the stereo-system. Conclusion: The addition of a second ToF-camera to determine patient displacement strongly improved patient repositioning results and therefore insures better radiation delivery.

  20. EndoTOFPET-US - A Miniaturised Calorimeter for Endoscopic Time-of-Flight Positron Emission Tomography

    NASA Astrophysics Data System (ADS)

    Zvolský, Milan; EndoTOFPET-US Collaboration

    2015-02-01

    In the scope of the EndoTOFPET-US project, a novel multimodal device for Ultrasound (US) Endoscopy and Positron Emission Tomography (PET) is being developed. The project aims at detecting and quantifying morphologic and functional markers and developing new biomarkers for pancreas and prostate oncology. Exploiting the Time-of-Flight (TOF) information of the gamma rays allows for a more sensitive, more precise and lower radiation- dose imaging and intervention on small internal structures. The detection of the gamma rays is realised with the help of scintillator crystals with Silicon Photomultiplier (SiPM) read-out, aiming at a coincidence time resolution of 200 ps and a spatial resolution of ≈ 1 mm. For the endoscopic detector, digital SiPMs are utilised for the first time in an instrument planned for clinical applications. The functionality of the instrument as well as the challenges that accompany the high miniaturisation of the endoscopic detector and the asymmetric and variable geometry of the system, are presented. The demands on the system involve the fields of scintillating crystallography, ultra-fast photon detection, highly integrated electronics, system integration as well as image reconstruction. The single detector components have been fully characterised and are performing up to specifications. Two dedicated ASIC chips have been developed for the project. The first PET images have been acquired with a test setup that consists solely of hardware and software developed within the collaboration and demonstrate that the data acquisition and reconstruction chain is operational. In this talk, the characterisation of the single components and the status of the detector integration and comissioning is presented.

  1. Development of analytically capable time-of-flight mass spectrometer with continuous ion introduction

    NASA Astrophysics Data System (ADS)

    Hárs, György; Dobos, Gábor

    2010-03-01

    The present article describes the results and findings explored in the course of the development of the analytically capable prototype of continuous time-of-flight (CTOF) mass spectrometer. Currently marketed pulsed TOF (PTOF) instruments use ion introduction with a 10 ns or so pulse width, followed by a waiting period roughly 100 μs. Accordingly, the sample is under excitation in 10-4 part of the total measuring time. This very low duty cycle severely limits the sensitivity of the PTOF method. A possible approach to deal with this problem is to use linear sinusoidal dual modulation technique (CTOF) as described in this article. This way the sensitivity of the method is increased, due to the 50% duty cycle of the excitation. All other types of TOF spectrometer use secondary electron multiplier (SEM) for detection, which unfortunately discriminates in amplification in favor of the lighter ions. This discrimination effect is especially undesirable in a mass spectrometric method, which targets high mass range. In CTOF method, SEM is replaced with Faraday cup detector, thus eliminating the mass discrimination effect. Omitting SEM is made possible by the high ion intensity and the very slow ion detection with some hundred hertz detection bandwidth. The electrometer electronics of the Faraday cup detector operates with amplification 1010 V/A. The primary ion beam is highly monoenergetic due to the construction of the ion gun, which made possible to omit any electrostatic mirror configuration for bunching the ions. The measurement is controlled by a personal computer and the intelligent signal generator Type Tabor WW 2571, which uses the direct digital synthesis technique for making arbitrary wave forms. The data are collected by a Labjack interface board, and the fast Fourier transformation is performed by the software. Noble gas mixture has been used to test the analytical capabilities of the prototype setup. Measurement presented proves the results of the mathematical

  2. High-performance electronics for time-of-flight PET systems.

    PubMed

    Choong, W-S; Peng, Q; Vu, C Q; Turko, B T; Moses, W W

    2013-01-01

    We have designed and built a high-performance readout electronics system for time-of-flight positron emission tomography (TOF PET) cameras. The electronics architecture is based on the electronics for a commercial whole-body PET camera (Siemens/CPS Cardinal electronics), modified to improve the timing performance. The fundamental contributions in the electronics that can limit the timing resolution include the constant fraction discriminator (CFD), which converts the analog electrical signal from the photo-detector to a digital signal whose leading edge is time-correlated with the input signal, and the time-to-digital converter (TDC), which provides a time stamp for the CFD output. Coincident events are identified by digitally comparing the values of the time stamps. In the Cardinal electronics, the front-end processing electronics are performed by an Analog subsection board, which has two application-specific integrated circuits (ASICs), each servicing a PET block detector module. The ASIC has a built-in CFD and TDC. We found that a significant degradation in the timing resolution comes from the ASIC's CFD and TDC. Therefore, we have designed and built an improved Analog subsection board that replaces the ASIC's CFD and TDC with a high-performance CFD (made with discrete components) and TDC (using the CERN high-performance TDC ASIC). The improved Analog subsection board is used in a custom single-ring LSO-based TOF PET camera. The electronics system achieves a timing resolution of 60 ps FWHM. Prototype TOF detector modules are read out with the electronics system and give coincidence timing resolutions of 259 ps FWHM and 156 ps FWHM for detector modules coupled to LSO and LaBr3 crystals respectively.

  3. Accurate characterization of carcinogenic DNA adducts using MALDI tandem time-of-flight mass spectrometry

    NASA Astrophysics Data System (ADS)

    Barnes, Charles A.; Chiu, Norman H. L.

    2009-01-01

    Many chemical carcinogens and their in vivo activated metabolites react readily with genomic DNA, and form covalently bound carcinogen-DNA adducts. Clinically, carcinogen-DNA adducts have been linked to various cancer diseases. Among the current methods for DNA adduct analysis, mass spectroscopic method allows the direct measurement of unlabeled DNA adducts. The goal of this study is to explore the use of matrix-assisted laser desorption/ionization tandem time-of-flight mass spectrometry (MALDI-TOF/TOF MS) to determine the identity of carcinogen-DNA adducts. Two of the known carcinogenic DNA adducts, namely N-(2'-deoxyguanosin-8-yl)-2-amino-1-methyl-6-phenyl-imidazo [4,5-b] pyridine (dG-C8-PhIP) and N-(2'-deoxyguanosin-8yl)-4-aminobiphenyl (dG-C8-ABP), were selected as our models. In MALDI-TOF MS measurements, the small matrix ion and its cluster ions did not interfere with the measurements of both selected dG adducts. To achieve a higher accuracy for the characterization of selected dG adducts, 1 keV collision energy in MALDI-TOF/TOF MS/MS was used to measure the adducts. In comparison to other MS/MS techniques with lower collision energies, more extensive precursor ion dissociations were observed. The detection of the corresponding fragment ions allowed the identities of guanine, PhIP or ABP, and the position of adduction to be confirmed. Some of the fragment ions of dG-C8-PhIP have not been reported by other MS/MS techniques.

  4. Characterization of drug-lysozyme conjugates by sheathless capillary electrophoresis-time-of-flight mass spectrometry.

    PubMed

    Haselberg, R; Harmsen, S; Dolman, M E M; de Jong, G J; Kok, R J; Somsen, G W

    2011-07-18

    Drug-protein conjugates have been widely used for the cell-specific targeting of drugs to cells that can bind and internalize the proteinaceous carrier. For renal drug targeting, lysozyme (LZM) can be used as an effective carrier that accumulates in proximal tubular cells. We used capillary electrophoresis-time-of-flight mass spectrometry (CE-TOF-MS) for the characterization of different drug-LZM conjugates. A recently developed prototype porous tip sprayer was employed for sheathless electrospray ionization (ESI) CE-MS interfacing. In order to prevent adsorption of LZM conjugates to the capillary wall, a positively charged polyethylenimine capillary coating was used in combination with a low-pH background electrolyte. Drug-LZM products had been prepared by first coupling BOC-l-methionine hydroxysuccinimide ester (BOCmet) to lysine residues of LZM followed by conjugation with the kinase inhibitors LY364947, erlotinib, or Y27632 via a platinum(II)-based linker. CE-TOF-MS of each preparation showed narrow symmetrical peaks for the various reaction products demonstrating that drug-LZM conjugates remained stable during the CE analysis and subsequent ESI. Components observed in the drug-LZM products were assigned based on their relative migration times and on molecular mass as obtained by TOF-MS. The TOF-MS data obtained for the individual components revealed that the preparations contained LZM carrying one or two drug molecules, next to unmodified and BOCmet-modified LZM. Based on relative peak areas (assuming an equimolar response for each component) a quantitative conjugate profile could be derived for every preparation leading to drug loading values of 0.4-0.6 mol drug per mole protein.

  5. Conceptual design of the time-of-flight backscattering spectrometer MIRACLES, at the European Spallation Source

    NASA Astrophysics Data System (ADS)

    Tsapatsaris, N.; Lechner, R. E.; Markó, M.; Bordallo, H. N.

    2016-08-01

    In this work, we present the conceptual design of the backscattering time-of-flight spectrometer MIRACLES approved for construction at the long-pulse European Spallation Source (ESS). MIRACLES's unparalleled combination of variable resolution, high flux, extended energy, and momentum transfer (0.2-6 Å-1) ranges will open new avenues for neutron backscattering spectroscopy. Its remarkable flexibility can be attributed to 3 key elements: the long-pulse time structure and low repetition rate of the ESS neutron source, the chopper cascade that tailors the moderator pulse in the primary part of the spectrometer, and the bent Si(111) analyzer crystals arranged in a near-backscattering geometry in the secondary part of the spectrometer. Analytical calculations combined with instrument Monte-Carlo simulations show that the instrument will provide a variable elastic energy resolution, δ(ħ ω), between 2 and 32 μeV, when using a wavelength of λ ≈ 6.267 Å (Si(111)-reflection), with an energy transfer range, ħ ω, centered at the elastic line from -600 to +600 μeV. In addition, when selecting λ ≈ 2.08 Å (i.e., the Si(333)-reflection), δ(ħ ω) can be relaxed to 300 μeV and ħ ω from about 10 meV in energy gain to ca -40 meV in energy loss. Finally, the dynamic wavelength range of MIRACLES, approximately 1.8 Å, can be shifted within the interval of 2-20 Å to allow the measurement of low-energy inelastic excitations.

  6. Fast time-of-flight camera based surface registration for radiotherapy patient positioning

    SciTech Connect

    Placht, Simon; Stancanello, Joseph; Schaller, Christian; Balda, Michael; Angelopoulou, Elli

    2012-01-15

    Purpose: This work introduces a rigid registration framework for patient positioning in radiotherapy, based on real-time surface acquisition by a time-of-flight (ToF) camera. Dynamic properties of the system are also investigated for future gating/tracking strategies. Methods: A novel preregistration algorithm, based on translation and rotation-invariant features representing surface structures, was developed. Using these features, corresponding three-dimensional points were computed in order to determine initial registration parameters. These parameters became a robust input to an accelerated version of the iterative closest point (ICP) algorithm for the fine-tuning of the registration result. Distance calibration and Kalman filtering were used to compensate for ToF-camera dependent noise. Additionally, the advantage of using the feature based preregistration over an ''ICP only'' strategy was evaluated, as well as the robustness of the rigid-transformation-based method to deformation. Results: The proposed surface registration method was validated using phantom data. A mean target registration error (TRE) for translations and rotations of 1.62 {+-} 1.08 mm and 0.07 deg. {+-} 0.05 deg., respectively, was achieved. There was a temporal delay of about 65 ms in the registration output, which can be seen as negligible considering the dynamics of biological systems. Feature based preregistration allowed for accurate and robust registrations even at very large initial displacements. Deformations affected the accuracy of the results, necessitating particular care in cases of deformed surfaces. Conclusions: The proposed solution is able to solve surface registration problems with an accuracy suitable for radiotherapy cases where external surfaces offer primary or complementary information to patient positioning. The system shows promising dynamic properties for its use in gating/tracking applications. The overall system is competitive with commonly-used surface

  7. MOEMS-based time-of-flight camera for 3D video capturing

    NASA Astrophysics Data System (ADS)

    You, Jang-Woo; Park, Yong-Hwa; Cho, Yong-Chul; Park, Chang-Young; Yoon, Heesun; Lee, Sang-Hun; Lee, Seung-Wan

    2013-03-01

    We suggest a Time-of-Flight (TOF) video camera capturing real-time depth images (a.k.a depth map), which are generated from the fast-modulated IR images utilizing a novel MOEMS modulator having switching speed of 20 MHz. In general, 3 or 4 independent IR (e.g. 850nm) images are required to generate a single frame of depth image. Captured video image of a moving object frequently shows motion drag between sequentially captured IR images, which results in so called `motion blur' problem even when the frame rate of depth image is fast (e.g. 30 to 60 Hz). We propose a novel `single shot' TOF 3D camera architecture generating a single depth image out of synchronized captured IR images. The imaging system constitutes of 2x2 imaging lens array, MOEMS optical shutters (modulator) placed on each lens aperture and a standard CMOS image sensor. The IR light reflected from object is modulated by optical shutters on the apertures of 2x2 lens array and then transmitted images are captured on the image sensor resulting in 2x2 sub-IR images. As a result, the depth image is generated with those simultaneously captured 4 independent sub-IR images, hence the motion blur problem is canceled. The resulting performance is very useful in the applications of 3D camera to a human-machine interaction device such as user interface of TV, monitor, or hand held devices and motion capturing of human body. In addition, we show that the presented 3D camera can be modified to capture color together with depth image simultaneously on `single shot' frame rate.

  8. The TORCH time-of-flight detector for particle identification and photon vertex association

    NASA Astrophysics Data System (ADS)

    Castillo García, L.; Brook, N.; Cussans, D.; Föhl, K.; Forty, R.; Frei, C.; Gao, R.; Gys, T.; Harnew, N.; Piedigrossi, D.; Rademacker, J.; Ros García, A.; van Dijk, M.

    2017-02-01

    TORCH (Time Of internally Reflected CHerenkov light) is a novel time-of-flight detector, designed to provide π /K/p particle identification up to 0~ 1 GeV/c momentum and beyond. To achieve this, a time resolution of ~ 15 ps combining information from 0~ 3 detected photons is required over a 10 m flight path. Large areas can be covered with TORCH, nominally up to 30 m2. One such application is for the LHCb experiment, to complement the particle identification capabilities of its RICH detectors. TORCH has a DIRC-like construction with 10 mm-thick synthetic amorphous fused-silica plates as a radiator. Cherenkov photons propagate by total internal reflection to the plate edges and there are focussed onto an array of position-sensitive photodetectors. Custom-built micro-channel plate photo-multipliers (MCP-PMTs) are being developed in collaboration with industry to provide the lifetime, granularity and time resolution to meet the TORCH specifications. In the present paper, laboratory tests of the MCP-PMTs developed for TORCH and its readout electronics are presented. Test beam measurements of a prototype TORCH detector in a low-momentum mixed beam of pions and protons are highlighted. Time resolutions for individual photons approaching 100 ps is achieved, after correction for dispersion effects in the quartz medium. In addition to the particle identification capabilities, the high-precision timing information that TORCH provides could be used at the high-luminosity LHC to associate high-energy photons with the correct primary interaction vertex amongst the many expected.

  9. SENJU: a new time-of-flight single-crystal neutron diffractometer at J-PARC.

    PubMed

    Ohhara, Takashi; Kiyanagi, Ryoji; Oikawa, Kenichi; Kaneko, Koji; Kawasaki, Takuro; Tamura, Itaru; Nakao, Akiko; Hanashima, Takayasu; Munakata, Koji; Moyoshi, Taketo; Kuroda, Tetsuya; Kimura, Hiroyuki; Sakakura, Terutoshi; Lee, Chang-Hee; Takahashi, Miwako; Ohshima, Ken-Ichi; Kiyotani, Tamiko; Noda, Yukio; Arai, Masatoshi

    2016-02-01

    SENJU is a new single-crystal time-of-flight neutron diffractometer installed at BL18 at the Materials and Life Science Experimental Facility of the Japan Accelerator Research Complex (J-PARC). The diffractometer was designed for precise crystal and magnetic structure analyses under multiple extreme sample environments such as low temperature, high pressure and high magnetic field, and for diffraction measurements of small single crystals down to 0.1 mm(3) in volume. SENJU comprises three choppers, an elliptical shape straight supermirror guide, a vacuum sample chamber and 37 scintillator area detectors. The moderator-to-sample distance is 34.8 m, and the sample-to-detector distance is 800 mm. The wavelength of incident neutrons is 0.4-4.4 Å (first frame). Because short-wavelength neutrons are available and the large solid angle around the sample position is covered by the area detectors, a large reciprocal space can be simultaneously measured. Furthermore, the vacuum sample chamber and collimator have been designed to produce a very low background level. Thus, the measurement of a small single crystal is possible. As sample environment devices, a newly developed cryostat with a two-axis (ω and φ axes) goniometer and some extreme environment devices, e.g. a vertical-field magnet, high-temperature furnace and high-pressure cell, are available. The structure analysis of a sub-millimetre size (0.1 mm(3)) single organic crystal, taurine, and a magnetic structure analysis of the antiferromagnetic phase of MnF2 have been performed. These results demonstrate that SENJU can be a powerful tool to promote materials science research.

  10. Time-Of-Flight Camera, Optical Tracker and Computed Tomography in Pairwise Data Registration

    PubMed Central

    Badura, Pawel; Juszczyk, Jan; Pietka, Ewa

    2016-01-01

    Purpose A growing number of medical applications, including minimal invasive surgery, depends on multi-modal or multi-sensors data processing. Fast and accurate 3D scene analysis, comprising data registration, seems to be crucial for the development of computer aided diagnosis and therapy. The advancement of surface tracking system based on optical trackers already plays an important role in surgical procedures planning. However, new modalities, like the time-of-flight (ToF) sensors, widely explored in non-medical fields are powerful and have the potential to become a part of computer aided surgery set-up. Connection of different acquisition systems promises to provide a valuable support for operating room procedures. Therefore, the detailed analysis of the accuracy of such multi-sensors positioning systems is needed. Methods We present the system combining pre-operative CT series with intra-operative ToF-sensor and optical tracker point clouds. The methodology contains: optical sensor set-up and the ToF-camera calibration procedures, data pre-processing algorithms, and registration technique. The data pre-processing yields a surface, in case of CT, and point clouds for ToF-sensor and marker-driven optical tracker representation of an object of interest. An applied registration technique is based on Iterative Closest Point algorithm. Results The experiments validate the registration of each pair of modalities/sensors involving phantoms of four various human organs in terms of Hausdorff distance and mean absolute distance metrics. The best surface alignment was obtained for CT and optical tracker combination, whereas the worst for experiments involving ToF-camera. Conclusion The obtained accuracies encourage to further develop the multi-sensors systems. The presented substantive discussion concerning the system limitations and possible improvements mainly related to the depth information produced by the ToF-sensor is useful for computer aided surgery developers

  11. Evaluation of quadrupole-time-of-flight mass spectrometry in comprehensive two-dimensional gas chromatography.

    PubMed

    Mitrevski, Blagoj; Marriott, Philip J

    2014-10-03

    Quadrupole time-of-flight mass spectrometry (Q-TOFMS) has been evaluated with respect to its applicability in comprehensive two-dimensional gas chromatography (GC×GC). At a maximum acquisition frequency, while approximately 50 full accurate mass spectra on disk were acquired per s (50Hz) in scan mode, the sampling rate in target mode (MS/MS) was strongly dependent on the number of target ions selected. The number of selected precursor ions per time window proportionally decreased the acquisition rate for each ion; one precursor ion ≅31.35Hz; two ions ≅16.68Hz; and for 8 precursor ions, a sampling rate of just 4.18Hz was found. When Q-TOFMS was used in simultaneous mode, where in addition to the acquisition of target ion MS/MS signals, it also collects the full mass spectrum, sampling rates were even lower. It is demonstrated that Q-TOFMS generates sufficient data points over each peak in GC×GC operation in scan mode using TOFMS acquisition only, or is able to collect sufficient data points for relatively wide chromatographic peaks (≥600ms) in the target mode (MS/MS), however only if one or two precursor ions are selected per time window. Mass accuracy was found to perform within specification (<5ppm), even for the fastest acquisition operation (50Hz). Spectral deconvolution is demonstrated to work better in GC×GC than in 1D GC mode. Data visualisation in target GC×GC mode presents difficulties when there are overlapping target windows comprising different numbers of precursor ions.

  12. Investigation of isovaline enantiomeric excesses in CM meteorites using liquid chromatography time of flight mass spectrometry

    NASA Technical Reports Server (NTRS)

    Glavin, Daniel P.; Dworkin, Jason P.

    2003-01-01

    The enantiomeric abundances of the alpha-dialkyl amino acid isovaline were measured in the CM2 meteorites Murchison and LEW 90500 using a new liquid chromatography-time of flight-mass spectrometry (LC-ToF-MS) technique coupled with OPA/NAC derivatization and UV fluorescence detection. Previous analyses of Murchison have shown that L-enantiomeric excesses of isovaline range from 0 to 15.2% with significant variation between meteorite fragments [1]. For this study, hot water extracts of interior fragments (> 2 cm from fusion crust) of the Murchison (USNM 6650.2, mass 6 g) and LEW 90500 (split 69, parent 1, mass 5 g) carbonaceous meteorites were analyzed. Enantiomeric excesses were measured using the single ion LC-ToF-MS trace for the OPA/NAC derivative of isovaline at d z 393.15 (Fig. 1). L-isovaline excesses in these meteorite samples ranged from 18.9 to 20.5% for Murchison and -0.5 to 3.0% for LEW 90500. The measured values for Murchison are the largest enantiomeric excesses for isovaline reported to date. The enantiomeric excesses of L-isovaline cannot be the result of interference from other C5 amino acid isomers present in the meteorites or terrestrial contamination from the landing site environments. The L-isovaline excesses in Murchison are inconsistent with the synthesis of all of the isovaline by the Strecker-cyanohydrin pathway on the CM meteorite parent body. The mechanism(s) for the formation of the enantiomeric asymmetry in isovaline in Murchison are currently unknown and it is not clear how the asymmetry of alpha-dialkyl amino acids could be transferred to the a-hydrogen protein amino acids common in all life on Earth today.

  13. Molecular depth profiling of multilayer polymer films using time-of-flight secondary ion mass spectrometry.

    PubMed

    Wagner, M S

    2005-02-01

    The low penetration depth and high sputter rates obtained using polyatomic primary ions have facilitated their use for the molecular depth profiling of some spin-cast polymer films by secondary ion mass spectrometry (SIMS). In this study, dual-beam time-of-flight (TOF) SIMS (sputter ion, 5 keV SF(5)(+); analysis ion, 10 keV Ar(+)) was used to depth profile spin-cast multilayers of poly(methyl methacrylate) (PMMA), poly(2-hydroxyethyl methacrylate) (PHEMA), and trifluoroacetic anhydride-derivatized poly(2-hydroxyethyl methacrylate) (TFAA-PHEMA) on silicon substrates. Characteristic positive and negative secondary ions were monitored as a function of depth using SF(5)(+) primary ion doses necessary to sputter through the polymer layer and uncover the silicon substrate (>5 x10(14) ions/cm(2)). The sputter rates of the polymers in the multilayers were typically less than for corresponding single-layer films, and the order of the polymers in the multilayer affected the sputter rates of the polymers. Multilayer samples with PHEMA as the outermost layer resulted in lowered sputter rates for the underlying polymer layer due to increased ion-induced damage accumulation rates in PHEMA. Additionally, the presence of a PMMA or PHEMA overlayer significantly decreased the sputter rate of TFAA-PHEMA underlayers due to ion-induced damage accumulation in the overlayer. Typical interface widths between adjacent polymer layers were 10-15 nm for bilayer films and increased with depth to approximately 35 nm for the trilayer films. The increase in interface width and observations using optical microscopy showed the formation of sputter-induced surface roughness during the depth profiles of the trilayer polymer films. This study shows that polyatomic primary ions can be used for the molecular depth profiling of some multilayer polymer films and presents new opportunities for the analysis of thin organic films using TOF-SIMS.

  14. High-performance electronics for time-of-flight PET systems

    NASA Astrophysics Data System (ADS)

    Choong, W.-S.; Peng, Q.; Vu, C. Q.; Turko, B. T.; Moses, W. W.

    2013-01-01

    We have designed and built a high-performance readout electronics system for time-of-flight positron emission tomography (TOF PET) cameras. The electronics architecture is based on the electronics for a commercial whole-body PET camera (Siemens/CPS Cardinal electronics), modified to improve the timing performance. The fundamental contributions in the electronics that can limit the timing resolution include the constant fraction discriminator (CFD), which converts the analog electrical signal from the photo-detector to a digital signal whose leading edge is time-correlated with the input signal, and the time-to-digital converter (TDC), which provides a time stamp for the CFD output. Coincident events are identified by digitally comparing the values of the time stamps. In the Cardinal electronics, the front-end processing electronics are performed by an Analog subsection board, which has two application-specific integrated circuits (ASICs), each servicing a PET block detector module. The ASIC has a built-in CFD and TDC. We found that a significant degradation in the timing resolution comes from the ASIC's CFD and TDC. Therefore, we have designed and built an improved Analog subsection board that replaces the ASIC's CFD and TDC with a high-performance CFD (made with discrete components) and TDC (using the CERN high-performance TDC ASIC). The improved Analog subsection board is used in a custom single-ring LSO-based TOF PET camera. The electronics system achieves a timing resolution of 60 ps FWHM. Prototype TOF detector modules are read out with the electronics system and give coincidence timing resolutions of 259 ps FWHM and 156 ps FWHM for detector modules coupled to LSO and LaBr3 crystals respectively.

  15. Time-Of-Flight Mass Spectrometry of Laser Exploding Foil Initiated PETN Samples

    NASA Astrophysics Data System (ADS)

    Fajardo, Mario

    2015-06-01

    We report the results of time-of-flight mass spectrometry (TOFMS) measurements of the gaseous products of thin film PETN samples reacting in-vacuo. The PETN sample spots are produced by masked physical vapor deposition of PETN onto a first-surface aluminum mirror. A pulsed laser beam imaged through the soda lime glass mirror substrate converts the aluminum layer into a high-temperature high-pressure plasma which initiates chemical reactions in the overlying PETN sample. We had previously proposed to exploit differences in gaseous product chemical identities and molecular velocities to provide a chemically-based diagnostic for distinguishing between ``detonation-like'' and deflagration responses. Briefly: we expect in-vacuum detonations to produce hyperthermal (v ~ 10 km/s) thermodynamically-stable products such as N2, CO2, and H2O, and for deflagrations to produce mostly reaction intermediates, such as NO and NO2, with much slower molecular velocities - consistent with the expansion-quenched thermal decomposition of PETN. We observe primarily slow reaction intermediates (NO2, CH2NO3) at low laser pulse energies, the appearance of NO at intermediate laser pulse energies, and the appearance of hyperthemal CO/N2 at mass 28 amu at the highest laser pulse energies. However, these results are somewhat ambiguous, as the NO, NO2, and CH2NO3 intermediates persist and all species become hyperthermal at the higher laser pulse energies. Also, the purported CO/N2 signal at 28 amu may be contaminated by silicon ablated from the glass mirror substrate. We plan to mitigate these problems in future experiments by adopting the ``Buelow'' sample configuration which employs an intermediate foil barrier to shield the energetic material from the laser and the laser driven plasma. [RW PA#4930

  16. The power of hyphenated chromatography/time-of-flight mass spectrometry in public health laboratories.

    PubMed

    Ibáñez, María; Portolés, Tania; Rúbies, Antoni; Muñoz, Eva; Muñoz, Gloria; Pineda, Laura; Serrahima, Eulalia; Sancho, Juan V; Centrich, Francesc; Hernández, Félix

    2012-05-30

    Laboratories devoted to the public health field have to face the analysis of a large number of organic contaminants/residues in many different types of samples. Analytical techniques applied in this field are normally focused on quantification of a limited number of analytes. At present, most of these techniques are based on gas chromatography (GC) or liquid chromatography (LC) coupled to tandem mass spectrometry (MS/MS). Using these techniques only analyte-specific information is acquired, and many other compounds that might be present in the samples would be ignored. In this paper, we explore the potential of time-of-flight (TOF) MS hyphenated to GC or LC to provide additional information, highly useful in this field. Thus, all positives reported by standard reference targeted LC-MS/MS methods were unequivocally confirmed by LC-QTOF MS. Only 61% of positives reported by targeted GC-MS/MS could be confirmed by GC-TOF MS, which was due to its lower sensitivity as nonconfirmations corresponded to analytes that were present at very low concentrations. In addition, the use of TOF MS allowed searching for additional compounds in large-scope screening methodologies. In this way, different contaminants/residues not included in either LC or GC tandem MS analyses were detected. This was the case of the insecticide thiacloprid, the plant growth regulator paclobutrazol, the fungicide prochloraz, or the UV filter benzophenone, among others. Finally, elucidation of unknowns was another of the possibilities offered by TOF MS thanks to the accurate-mass full-acquisition data available when using this technique.

  17. Time-of-Flight Mass Spectrometry with a Pulsed Glow Discharge Ionization Source.

    PubMed

    Steiner, R E; Lewis, C L; King, F L

    1997-05-01

    The pulsed glow discharge (GD) plasma source exhibits several characteristics that make it ideally suited for use with time-of-flight mass spectrometry (TOFMS). TOFMS uniquely affords the ability to monitor a narrow temporal window for a time-varying process such as ion formation in the pulsed glow discharge plasma. Pulsed GD-TOFMS exhibited distinct advantages for the direct determination of trace elements in solid state samples. Initially, the pulse-powered GD-TOFMS system used for these investigations exhibited poor resolution. In an effort to improve resolution, a slit was introduced to narrow the ion beam orthogonally entering the extraction region of the TOFMS. In an effort to determine optimal operating conditions, the influence of slit width on TOF performance was investigated. In the course of this study, the slit width was found to influence isotope ratio accuracy as well as resolution. A slit width of 1.0 mm was determined to provide the best compromise between resolution and isotope ratio accuracy. Pulsed GD-TOFMS affords improved sensitivity and selectivity because Penning ionization is enhanced during the time period immediately following the termination of the discharge power. Ions sampled by an extraction pulse applied after power termination also yield a mass spectrum that is free of contributions arising from electron-ionized interferences. This advantage arises because only ions generated via the Penning ionization mechanism persist after the termination of discharge power. Sampling in the "afterpeak" time regime eliminates the saturation of the detector arising from discharge support gas ion signal.

  18. Implementation of Ion/Ion Reactions in a Quadrupole/Time-of-Flight Tandem Mass Spectrometer

    PubMed Central

    Xia, Yu; Chrisman, Paul A.; Erickson, David E.; Liu, Jian; Liang, Xiaorong; Londry, Frank A.; Yang, Min J.; McLuckey, Scott A.

    2008-01-01

    A commercial quadrupole/time-of-flight (QqTOF) tandem mass spectrometer has been adapted for ion/ion reaction studies. To enable mutual storage of oppositely charged ions in a linear ion trap, the oscillating quadrupole field of the second quadrupole of the system (Q2) serves to store ions in the radial dimension while auxiliary RF is superposed on the end lenses of Q2 during the reaction period to create barriers in the axial dimension. A pulsed dual electrospray (ESI) source is directly coupled to the instrument interface for the purpose of proton transfer reactions. Singly and doubly charged protein ions as high in mass as 66 kDa are readily formed and observed after proton transfer reactions. For the modified instrument, the mass resolving power is about 8000 for a wide m/z range and the mass accuracy is ~20 ppm for external calibration and ~5 ppm for internal calibration after ion/ion reactions. Parallel ion parking is demonstrated with a six-component protein mixture, which shows the potential application of reducing spectral complexity and concentrating certain charge states. The current system has high flexibility with respect to defining MSn experiments involving collision-induced dissociation (CID) and ion/ion reactions. Protein precursor and CID product masses can be determined with good accuracy, providing an attractive platform for top-down proteomics. Electron transfer dissociation (ETD) ion/ion reactions are implemented by using a pulsed nano-ESI/atmospheric pressure chemical ionization (APCI) dual source for ionization. The reaction between protonated peptide ions and radical anions of 1,3-dinitrobenzene formed exclusively c- and z- type fragment ions. PMID:16771545

  19. CF NEUTRON TIME OF FLIGHT TRANSMISSION FOR MATERIAL IDENTIFICATION FOR WEAPONS TRAINERS

    SciTech Connect

    Mihalczo, John T; Valentine, Timothy E; Blakeman, Edward D; Pare, Victor

    2011-01-01

    The neutron transmission, elastic scattering, and non elastic reactions can be used to distinguish various isotopes. Neutron transmission as a function of energy can be used in some cases to identify materials in unknown objects. A time tagged californium source that provides a fission spectrum of neutrons is a useful source for neutron time-of-flight (TOF) transmission measurements. Many nuclear weapons trainer units for a particular weapons system (no fissile, but of same weight and center of gravity) in shipping containers were returned to the National Nuclear Security Administration Y-12 National Security Complex in the mid 1990s. Nuclear Materials Identification System (NMIS) measurements with a time tagged californium neutron source were used to verify that these trainers did not contain fissile material. In these blind tests, the time distributions of neutrons through the containers were measured as a function of position to locate the approximate center of the trainer in the container. Measurements were also performed with an empty container. TOF template matching measurements were then performed at this location for a large number of units. In these measurements, the californium source was located on one end of the container and a proton recoil scintillator was located on the other end. The variations in the TOF transmission for times corresponding to 1 to 5 MeV were significantly larger than statistical. Further examination of the time distribution or the energy dependence revealed that these variations corresponded to the variations in the neutron cross section of aluminum averaged over the energy resolution of the californium TOF measurement with a flight path of about 90 cm. Measurements using different thicknesses of aluminum were also performed with the source and detector separated the same distance as for the trainer measurements. These comparison measurements confirmed that the material in the trainers was aluminum, and the total thickness of

  20. Towards practical time-of-flight secondary ion mass spectrometry lignocellulolytic enzyme assays

    PubMed Central

    2013-01-01

    Background Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) is a surface sensitive mass spectrometry technique with potential strengths as a method for detecting enzymatic activity on solid materials. In particular, ToF-SIMS has been applied to detect the enzymatic degradation of woody lignocellulose. Proof-of-principle experiments previously demonstrated the detection of both lignin-degrading and cellulose-degrading enzymes on solvent-extracted hardwood and softwood. However, these preliminary experiments suffered from low sample throughput and were restricted to samples which had been solvent-extracted in order to minimize the potential for mass interferences between low molecular weight extractive compounds and polymeric lignocellulose components. Results The present work introduces a new, higher-throughput method for processing powdered wood samples for ToF-SIMS, meanwhile exploring likely sources of sample contamination. Multivariate analysis (MVA) including Principal Component Analysis (PCA) and Multivariate Curve Resolution (MCR) was regularly used to check for sample contamination as well as to detect extractives and enzyme activity. New data also demonstrates successful ToF-SIMS analysis of unextracted samples, placing an emphasis on identifying the low-mass secondary ion peaks related to extractives, revealing how extractives change previously established peak ratios used to describe enzyme activity, and elucidating peak intensity patterns for better detection of cellulase activity in the presence of extractives. The sensitivity of ToF-SIMS to a range of cellulase doses is also shown, along with preliminary experiments augmenting the cellulase cocktail with other proteins. Conclusions These new procedures increase the throughput of sample preparation for ToF-SIMS analysis of lignocellulose and expand the applications of the method to include unextracted lignocellulose. These are important steps towards the practical use of ToF-SIMS as a tool to

  1. SENJU: a new time-of-flight single-crystal neutron diffractometer at J-PARC

    PubMed Central

    Ohhara, Takashi; Kiyanagi, Ryoji; Oikawa, Kenichi; Kaneko, Koji; Kawasaki, Takuro; Tamura, Itaru; Nakao, Akiko; Hanashima, Takayasu; Munakata, Koji; Moyoshi, Taketo; Kuroda, Tetsuya; Kimura, Hiroyuki; Sakakura, Terutoshi; Lee, Chang-Hee; Takahashi, Miwako; Ohshima, Ken-ichi; Kiyotani, Tamiko; Noda, Yukio; Arai, Masatoshi

    2016-01-01

    SENJU is a new single-crystal time-of-flight neutron diffractometer installed at BL18 at the Materials and Life Science Experimental Facility of the Japan Accelerator Research Complex (J-PARC). The diffractometer was designed for precise crystal and magnetic structure analyses under multiple extreme sample environments such as low temperature, high pressure and high magnetic field, and for diffraction measurements of small single crystals down to 0.1 mm3 in volume. SENJU comprises three choppers, an elliptical shape straight supermirror guide, a vacuum sample chamber and 37 scintillator area detectors. The moderator-to-sample distance is 34.8 m, and the sample-to-detector distance is 800 mm. The wavelength of incident neutrons is 0.4–4.4 Å (first frame). Because short-wavelength neutrons are available and the large solid angle around the sample position is covered by the area detectors, a large reciprocal space can be simultaneously measured. Furthermore, the vacuum sample chamber and collimator have been designed to produce a very low background level. Thus, the measurement of a small single crystal is possible. As sample environment devices, a newly developed cryostat with a two-axis (ω and φ axes) goniometer and some extreme environment devices, e.g. a vertical-field magnet, high-temperature furnace and high-pressure cell, are available. The structure analysis of a sub-millimetre size (0.1 mm3) single organic crystal, taurine, and a magnetic structure analysis of the antiferromagnetic phase of MnF2 have been performed. These results demonstrate that SENJU can be a powerful tool to promote materials science research. PMID:26937237

  2. High energy collisions on tandem time-of-flight mass spectrometers.

    PubMed

    Cotter, Robert J

    2013-05-01

    Long before the introduction of matrix-assisted laser desorption/ionization (MALDI), electrospray ionization (ESI), Orbitraps, and any of the other tools that are now used ubiquitously for proteomics and metabolomics, the highest performance mass spectrometers were sector instruments, providing high resolution mass measurements by combining an electrostatic energy analyzer (E) with a high field magnet (B). In its heyday, the four sector mass spectrometer (or EBEB) was the crown jewel, providing the highest performance tandem mass spectrometry using single, high energy collisions to induce fragmentation. During a time in which quadrupole and tandem triple quadrupole instruments were also enjoying increased usage and popularity, there were, nonetheless, some clear advantages for sectors over their low collision energy counterparts. Time-of-flight (TOF) mass spectrometers are high voltage, high vacuum instruments that have much in common with sectors and have inspired the development of tandem instruments exploiting single high energy collisions. In this retrospective, we recount our own journey to produce high performance TOFs and tandem TOFs, describing the basic theory, problems, and the advantages for such instruments. An experiment testing impulse collision theory (ICT) underscores the similarities with sector mass spectrometers where this concept was first developed. Applications provide examples of more extensive fragmentation, side chain cleavages, and charge-remote fragmentation, also characteristic of high energy sector mass spectrometers. Moreover, the so-called curved-field reflectron has enabled the design of instruments that are simpler, collect and focus all of the ions, and may provide the future technology for the clinic, for tissue imaging, and the characterization of microorganisms.

  3. SPADnet: a fully digital, scalable, and networked photonic component for time-of-flight PET applications

    NASA Astrophysics Data System (ADS)

    Bruschini, Claudio; Charbon, Edoardo; Veerappan, Chockalingam; Braga, Leo H. C.; Massari, Nicola; Perenzoni, Matteo; Gasparini, Leonardo; Stoppa, David; Walker, Richard; Erdogan, Ahmet; Henderson, Robert K.; East, Steve; Grant, Lindsay; Játékos, Balázs; Ujhelyi, Ferenc; Erdei, Gábor; Lörincz, Emöke; André, Luc; Maingault, Laurent; Jacolin, David; Verger, L.; Gros d'Aillon, Eric; Major, Peter; Papp, Zoltan; Nemeth, Gabor

    2014-05-01

    The SPADnet FP7 European project is aimed at a new generation of fully digital, scalable and networked photonic components to enable large area image sensors, with primary target gamma-ray and coincidence detection in (Time-of- Flight) Positron Emission Tomography (PET). SPADnet relies on standard CMOS technology, therefore allowing for MRI compatibility. SPADnet innovates in several areas of PET systems, from optical coupling to single-photon sensor architectures, from intelligent ring networks to reconstruction algorithms. It is built around a natively digital, intelligent SPAD (Single-Photon Avalanche Diode)-based sensor device which comprises an array of 8×16 pixels, each composed of 4 mini-SiPMs with in situ time-to-digital conversion, a multi-ring network to filter, carry, and process data produced by the sensors at 2Gbps, and a 130nm CMOS process enabling mass-production of photonic modules that are optically interfaced to scintillator crystals. A few tens of sensor devices are tightly abutted on a single PCB to form a so-called sensor tile, thanks to TSV (Through Silicon Via) connections to their backside (replacing conventional wire bonding). The sensor tile is in turn interfaced to an FPGA-based PCB on its back. The resulting photonic module acts as an autonomous sensing and computing unit, individually detecting gamma photons as well as thermal and Compton events. It determines in real time basic information for each scintillation event, such as exact time of arrival, position and energy, and communicates it to its peers in the field of view. Coincidence detection does therefore occur directly in the ring itself, in a differed and distributed manner to ensure scalability. The selected true coincidence events are then collected by a snooper module, from which they are transferred to an external reconstruction computer using Gigabit Ethernet.

  4. N-terminal H3/D3-acetylation for improved high-throughput peptide sequencing by matrix-assisted laser desorption/ionization mass spectrometry with a time-of-flight/time-of-flight analyzer.

    PubMed

    Noga, Marek J; Asperger, Arndt; Silberring, Jerzy

    2006-01-01

    A novel method for peptide sequencing by matrix-assisted laser desorption/ionization mass spectrometry with a time-of-flight/time-of-flight analyzer (MALDI-TOF/TOF) is presented. A stable isotope label introduced in the peptide N-terminus by derivatization, using a 1:1 mixture of acetic anhydride and deuterated acetic anhydride, allows for easy and unambiguous identification of ions belonging either to the N- or the C-terminal ion series in the product ion spectrum, making sequence assignment significantly simplified. The good performance of this technique was shown by successful sequencing of the contents of several peptide maps. A similar approach was recently applied to nanoelectrospray ionization (nanoESI) and nano-liquid chromatography/tandem mass spectrometry (LC/MS/MS). The MALDI-TOF/TOF technique allows for fast, direct sequencing of modified peptides in proteomics samples, and is complementary to the nanoESI and nanoLC/MS/MS approaches.

  5. Bismuth germanate coupled to near ultraviolet silicon photomultipliers for time-of-flight PET

    NASA Astrophysics Data System (ADS)

    Kwon, Sun Il; Gola, Alberto; Ferri, Alessandro; Piemonte, Claudio; Cherry, Simon R.

    2016-09-01

    Bismuth germanate (BGO) was a very attractive scintillator in early-generation positron emission tomography (PET) scanners. However, the major disadvantages of BGO are lower light yield and longer rise and decay time compared to currently popular scintillators such as LSO and LYSO. This results in poorer coincidence timing resolution and it has generally been assumed that BGO is not a suitable scintillator for time-of-flight (TOF) PET applications. However, when a 511 keV photon interacts in a scintillator, a number of Cerenkov photons are produced promptly by energetic electrons released by photoelectric or Compton interactions. If these prompt photons can be captured, they could provide a better timing trigger for PET. Since BGO has a high refractive index (increasing the Cerenkov light yield) and excellent optical transparency down to 320 nm (Cerenkov light yield is higher at shorter wavelengths), we hypothesized that the coincidence timing resolution of BGO can be significantly improved by efficient detection of the Cerenkov photons. However, since the number of Cerenkov photons is far less than the number of scintillation photons, and they are more abundant in the UV and blue part of the spectrum, photosensors need to have high UV/blue sensitivity, fast temporal response, and very low noise in order to trigger on the faint Cerenkov signal. In this respect, NUV-HD silicon photomultipliers (SiPMs) (FBK, Trento, Italy) are an excellent fit for our approach. In this study, coincidence events were measured using BGO crystals coupled with NUV-HD SiPMs. The existence and influence of Cerenkov photons on the timing measurements were studied using different configurations to exploit the directionality of the Cerenkov emissions. Coincidence resolving time values (FWHM) of ~270 ps from 2  ×  3  ×  2 mm3 BGO crystals and ~560 ps from 3  ×  3  ×  20 mm3 BGO crystals were obtained. To our knowledge, these are the best

  6. A unified Fourier theory for time-of-flight PET data.

    PubMed

    Li, Yusheng; Matej, Samuel; Metzler, Scott D

    2016-01-21

    Fully 3D time-of-flight (TOF) PET scanners offer the potential of previously unachievable image quality in clinical PET imaging. TOF measurements add another degree of redundancy for cylindrical PET scanners and make photon-limited TOF-PET imaging more robust than non-TOF PET imaging. The data space for 3D TOF-PET data is five-dimensional with two degrees of redundancy. Previously, consistency equations were used to characterize the redundancy of TOF-PET data. In this paper, we first derive two Fourier consistency equations and Fourier-John equation for 3D TOF PET based on the generalized projection-slice theorem; the three partial differential equations (PDEs) are the dual of the sinogram consistency equations and John's equation. We then solve the three PDEs using the method of characteristics. The two degrees of entangled redundancy of the TOF-PET data can be explicitly elicited and exploited by the solutions of the PDEs along the characteristic curves, which gives a complete understanding of the rich structure of the 3D x-ray transform with TOF measurement. Fourier rebinning equations and other mapping equations among different types of PET data are special cases of the general solutions. We also obtain new Fourier rebinning and consistency equations (FORCEs) from other special cases of the general solutions, and thus we obtain a complete scheme to convert among different types of PET data: 3D TOF, 3D non-TOF, 2D TOF and 2D non-TOF data. The new FORCEs can be used as new Fourier-based rebinning algorithms for TOF-PET data reduction, inverse rebinnings for designing fast projectors, or consistency conditions for estimating missing data. Further, we give a geometric interpretation of the general solutions--the two families of characteristic curves can be obtained by respectively changing the azimuthal and co-polar angles of the biorthogonal coordinates in Fourier space. We conclude the unified Fourier theory by showing that the Fourier consistency equations are

  7. BGO as a hybrid scintillator / Cherenkov radiator for cost-effective time-of-flight PET.

    PubMed

    Brunner, Stefan E; Schaart, Dennis

    2017-03-30

    Due to detector developments in the last decade, the time-of-flight (TOF) method is now commonly used to improve the quality of positron emission tomography (PET) images. Clinical TOF-PET systems based on L(Y)SO:Ce crystals and silicon photomultipliers (SiPMs) with coincidence resolving times (CRT) between 325 ps and 400 ps FWHM have recently been developed. Before the introduction of L(Y)SO:Ce, BGO was used in many PET systems. In addition to a lower price, BGO offers a superior attenuation coefficient and a higher photoelectric fraction than L(Y)SO:Ce. However, BGO is generally considered an inferior TOF-PET scintillator. In recent years, TOF-PET detectors based on the Cherenkov effect have been proposed. However, the low Cherenkov photon yield in the order of ∽10 photons per event complicates energy discrimination-a severe disadvantage in clinical PET. The optical characteristics of BGO, in particular its high transparency down to 310 nm and its high refractive index of ∽2.15, are expected to make it a good Cherenkov radiator. Here, we study the feasibility of combining event timing based on Cherenkov emission with energy discrimination based on scintillation in BGO, as a potential approach towards a cost-effective TOF-PET detector. Rise time measurements were performed using a time-correlated single photon counting (TCSPC) setup implemented on a digital photon counter (DPC) array, revealing a prompt luminescent component likely to be due to Cherenkov emission. Coincidence timing measurements were performed using BGO crystals with a cross-section of 3 mm × 3 mm and five different lengths between 3 mm and 20 mm, coupled to DPC arrays. Non-Gaussian coincidence spectra with a FWHM of 200 ps were obtained with the 27 mm3 BGO cubes, while FWHM values as good as 330 ps were achieved with the 20 mm long crystals. The FWHM value was found to improve with decreasing temperature, while the FWTM value showed the opposite trend.

  8. A unified Fourier theory for time-of-flight PET data

    PubMed Central

    Li, Yusheng; Matej, Samuel; Metzler, Scott D

    2016-01-01

    Fully 3D time-of-flight (TOF) PET scanners offer the potential of previously unachievable image quality in clinical PET imaging. TOF measurements add another degree of redundancy for cylindrical PET scanners and make photon-limited TOF-PET imaging more robust than non-TOF PET imaging. The data space for 3D TOF-PET data is five-dimensional with two degrees of redundancy. Previously, consistency equations were used to characterize the redundancy of TOF-PET data. In this paper, we first derive two Fourier consistency equations and Fourier-John equation for 3D TOF PET based on the generalized projection-slice theorem; the three partial differential equations (PDEs) are the dual of the sinogram consistency equations and John's equation. We then solve the three PDEs using the method of characteristics. The two degrees of entangled redundancy of the TOF-PET data can be explicitly elicited and exploited by the solutions of the PDEs along the characteristic curves, which gives a complete understanding of the rich structure of the 3D X-ray transform with TOF measurement. Fourier rebinning equations and other mapping equations among different types of PET data are special cases of the general solutions. We also obtain new Fourier rebinning and consistency equations (FORCEs) from other special cases of the general solutions, and thus we obtain a complete scheme to convert among different types of PET data: 3D TOF, 3D non-TOF, 2D TOF and 2D non-TOF data. The new FORCEs can be used as new Fourier-based rebinning algorithms for TOF-PET data reduction, inverse rebinnings for designing fast projectors, or consistency conditions for estimating missing data. Further, we give a geometric interpretation of the general solutions—the two families of characteristic curves can be obtained by respectively changing the azimuthal and co-polar angles of the biorthogonal coordinates in Fourier space. We conclude the unified Fourier theory by showing that the Fourier consistency equations are

  9. Time-of-flight mass spectrometry of laser exploding foil initiated PETN samples

    NASA Astrophysics Data System (ADS)

    Fajardo, Mario E.; Molek, Christopher D.; Fossum, Emily C.

    2017-01-01

    We report the results of time-of-flight mass spectrometry (TOFMS) measurements of the gaseous products of thin-film pentaerythritol tetranitrate [PETN, C(CH2NO3)4] samples reacting in vacuo. The PETN sample spots are produced by masked physical vapor deposition [A.S. Tappan, et al., AIP Conf. Proc. 1426, 677 (2012)] onto a first-surface aluminum mirror. A pulsed laser beam imaged through the soda lime glass mirror substrate converts the aluminum layer into a high-temperature high-pressure plasma which initiates chemical reactions in the overlying PETN sample. We had previously proposed [E.C. Fossum, et al., AIP Conf. Proc. 1426, 235 (2012)] to exploit differences in gaseous product chemical identities and molecular velocities to provide a chemically-based diagnostic for distinguishing between "detonation-like" and deflagration responses. Briefly: we expect in-vacuum detonations to produce hyperthermal (v˜10 km/s) thermodynamically-stable products such as N2, CO2, and H2O, and for deflagrations to produce mostly reaction intermediates, such as NO and NO2, with much slower molecular velocities - consistent with the expansion-quenched thermal decomposition of PETN. We observe primarily slow reaction intermediates (NO2, CH2NO3) at low laser pulse energies, the appearance of NO at intermediate laser pulse energies, and the appearance of hyperthemal CO/N2 at mass 28 amu at the highest laser pulse energies. However, these results are somewhat ambiguous, as the NO, NO2, and CH2NO3 intermediates persist and all species become hyperthermal at the higher laser pulse energies. Also, the purported CO/N2 signal at 28 amu may be contaminated by silicon ablated from the glass mirror substrate. We plan to mitigate these problems in future experiments by adopting the "Buelow" sample configuration which employs an intermediate foil barrier to shield the energetic material from the laser and the laser driven plasma [S.J. Buelow, et al., AIP Conf. Proc. 706, 1377 (2003)].

  10. Analysis of high-kappa dielectric thin films with time-of-flight medium energy backscattering

    NASA Astrophysics Data System (ADS)

    Geil, Robert D.

    Time-of-flight medium backscattering (TOF-MEBS) is a powerful analytical technique for characterizing high-kappa dielectric thin films and their interface with Si. The amount of information that can be obtained from backscattering experiments can be maximized by carefully choosing a detailed thin film model for simulations and by implementing an experimental configuration that optimizes depth resolution. This thesis presents four main studies. In the first study a thin film model for simulating backscattering spectra is developed and used to extract interfacial information from thin dielectric films. A sufficient film model was found to consist of three layers: (1) dielectric material; (2) interfacial silicate; and (3) substrate. In the next study, the influence of multiple scattering and surface roughness on the shape of backscattering spectra was evaluated by generating spectra using Monte Carlo simulations. For TOF-MEBS analysis of thin (˜50 A) ZrO 2 films on Si, multiple scattering and surface roughness were found to have a negligible influence on the shape of a backscattering spectrum. The third study presents calculations and measurements of the energy and depth resolution of the TOF-MEBS system, and the experimental configuration for optimizing depth resolution was determined. For the analysis of thin films (˜50 A), the depth resolution of the TOF-MEBS system can be improved by operating at a beam energy around 150 keV and by using a glancing tilt angle (˜54°). However, if the angle is too glancing, multiple scattering and surface roughness can significantly degrade depth resolution and distort the shape of the backscattering spectrum. ZrO2 films deposited on H-terminated Si and native Si oxide surfaces were characterized with TOF-MEBS for the final study. The deposition surface was found to significantly affect the physical and chemical properties of MOCVD ZrO2 films and their interface with Si. ZrO2 films deposited on H-terminated Si are low in density

  11. Comparison of Different Time of Flight-Mass Spectrometry Modes for Small Molecule Quantitative Analysis.

    PubMed

    Chindarkar, Nandkishor S; Park, Hyung-Doo; Stone, Judith A; Fitzgerald, Robert L

    2015-01-01

    Currently, the use of time of flight (TOF)-mass spectrometry (MS) in quantitative analysis of small molecules is rare. Recently, the quantitative performance of TOF mass analyzers has improved due to the advancements in TOF technology. We evaluated a Q-TOF-MS in different modes, i.e., Q-TOF-full scan (Q-TOF-FS), Q-TOF-enhanced-full scan (Q-TOF-En-FS), MS(E), Q-TOF-targeted (Q-TOF-TGT), Q-TOF-enhanced-targeted (Q-TOF-En-TGT), and compared their quantitative performance against a unit resolution LC-MS-MS (tandem quadrupole) platform. The five modes were investigated for sensitivity, linearity, signal-to-noise ratio, recovery and precision using 11-nor-9-carboxy-Δ(9)-tetrahydrocannabinol (THC-COOH) as a model compound in electrospray ionization (ESI) with negative polarity. Preliminary studies indicated that Q-TOF-FS mode was the least linear and precise; hence, it was eliminated from further investigation. Total imprecision in remaining four modes was <10%. The Q-TOF-En-FS and Q-TOF-En-TGT showed better signal intensity than their respective modes without enhancement. Overall, peak signal intensity was the highest in MS(E) mode, whereas the signal-to-noise ratio was the best in the Q-TOF-En-TGT mode. Relatively, MS(E) and Q-TOF-En-TGT modes were the best overall performers compared with the other modes. Both MS(E) and Q-TOF-En-TGT modes showed excellent precision (coefficient of variation <6%), patient correlation (r > 0.99) and linearity (range, 5-455 ng/mL) for THC-COOH analysis when compared with LC-MS-MS. We also investigated the performance of the same four modes using methamphetamine in positive ESI. Quantitative data obtained by Q-TOF-En-TGT and MS(E), using both positive and negative ESI, suggest that these modes performed better than the other modes. While unit resolution LC-MS-MS remains the optimal technique for quantification, our data showed that Q-TOF-MS can also be used to quantify small molecules in complex biological specimens.

  12. A unified Fourier theory for time-of-flight PET data

    NASA Astrophysics Data System (ADS)

    Li, Yusheng; Matej, Samuel; Metzler, Scott D.

    2016-01-01

    Fully 3D time-of-flight (TOF) PET scanners offer the potential of previously unachievable image quality in clinical PET imaging. TOF measurements add another degree of redundancy for cylindrical PET scanners and make photon-limited TOF-PET imaging more robust than non-TOF PET imaging. The data space for 3D TOF-PET data is five-dimensional with two degrees of redundancy. Previously, consistency equations were used to characterize the redundancy of TOF-PET data. In this paper, we first derive two Fourier consistency equations and Fourier-John equation for 3D TOF PET based on the generalized projection-slice theorem; the three partial differential equations (PDEs) are the dual of the sinogram consistency equations and John’s equation. We then solve the three PDEs using the method of characteristics. The two degrees of entangled redundancy of the TOF-PET data can be explicitly elicited and exploited by the solutions of the PDEs along the characteristic curves, which gives a complete understanding of the rich structure of the 3D x-ray transform with TOF measurement. Fourier rebinning equations and other mapping equations among different types of PET data are special cases of the general solutions. We also obtain new Fourier rebinning and consistency equations (FORCEs) from other special cases of the general solutions, and thus we obtain a complete scheme to convert among different types of PET data: 3D TOF, 3D non-TOF, 2D TOF and 2D non-TOF data. The new FORCEs can be used as new Fourier-based rebinning algorithms for TOF-PET data reduction, inverse rebinnings for designing fast projectors, or consistency conditions for estimating missing data. Further, we give a geometric interpretation of the general solutions—the two families of characteristic curves can be obtained by respectively changing the azimuthal and co-polar angles of the biorthogonal coordinates in Fourier space. We conclude the unified Fourier theory by showing that the Fourier consistency equations

  13. Characterization of submicron aerosols during a serious pollution month in Beijing (2013) using an aerodyne high-resolution aerosol mass spectrometer

    NASA Astrophysics Data System (ADS)

    Zhang, J. K.; Sun, Y.; Liu, Z. R.; Ji, D. S.; Hu, B.; Liu, Q.; Wang, Y. S.

    2013-07-01

    In January 2013, Beijing experienced several serious haze events. To achieve a better understanding of the characteristics, sources and processes of aerosols during this month, an Aerodyne High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS) was deployed at an urban site between 1 January and 1 February 2013 to obtain the size-resolved chemical composition of non-refractory submicron particles (NR-PM1). During this period, the mean measured NR-PM1 mass concentration was 87.4 μg m-3 and was composed of organics (49.8%), sulfate (21.4%), nitrate (14.6%), ammonium (10.4%), and chloride (3.8%). Moreover, inorganic matter, such as sulfate and nitrate comprised an increasing fraction of the NR-PM1 load as NR-PM1 loading increased, denoting their key roles in particulate pollution during this month. The average size distributions of the species were all dominated by an accumulation mode peaking at approximately 600 nm in vacuum aerodynamic diameter and organics characterized by an additional smaller size (∼200 nm). Elemental analyses showed that the average O/C, H/C, and N/C (molar ratio) of organic matter were 0.34, 1.44 and 0.015, respectively, corresponding to an OM/OC ratio (mass ratio of organic matter to organic carbon) of 1.60. Positive matrix factorization (PMF) analyses of the high-resolution organic mass spectral dataset differentiated the organic aerosol into four components, i.e., oxygenated organic aerosols (OOA), cooking-related (COA), nitrogen-containing (NOA) and hydrocarbon-like (HOA), which on average accounted for 40.0, 23.4, 18.1 and 18.5% of the total organic mass, respectively. Back trajectory clustering analyses indicated that the WNW air masses were associated with the highest NR-PM1 pollution during the campaign. Aerosol particles in southern air masses were especially rich in inorganic and oxidized organic species, whereas northern air masses contained a large fraction of primary species.

  14. Development of a time-of-flight mass spectrometer combined with an ion-attachment method for multicomponent gas analysis

    NASA Astrophysics Data System (ADS)

    Takaya, Kazunari; Takahashi, Karin; Deguchi, Yuri; Sakai, Yasuhiro

    2014-10-01

    We developed a new mass spectrometer that can analyse multicomponent gases without fragmentation. This is essentially a time-of-flight (TOF) mass analyser in which the ion attachment method is used for ionisation. The method using this new device is referred to as “time-of-flight analysis in combination with ion-attachment” (TOFIA). TOFIA has the capability to analyse breath gas in about 10 min using the radio-frequency (RF) ion-guiding method and a multichannel scaler (MCS). The mass resolution of the trial device was unsatisfactory, but the device can be greatly improved in the future. We successfully analysed exhaled breath gases related to diseases, including ammonia, acetone, and isoprene gases. We expect that the TOFIA device developed in this work will contribute significantly to studies on the relationship between breath gas and health.

  15. Status of the front-end-electronics for the time-of-flight measurements at the MPD experiment

    NASA Astrophysics Data System (ADS)

    Buryakov, M. G.; Babkin, V. A.; Golovatyuk, V. M.; Volgin, S. V.; Rumyantsev, M. M.

    2016-09-01

    The preamplifier based on the ASIC NINO for the Time of Flight system (TOF) of MPD/NICA was developed and tested. The signal is read from both sides of the strip of the multi gap Resistive Plate Chamber (MRPC). In total there are around 14000 channels of electronics. To measure time of flight of secondary particles from collision of heavy ions on the collider NICA the Time over Threshold (ToT) method is used. According to the bench tests the preamplifier board showed stable work and good time resolution <10 ps for one channel. It was also tested at the test beam facility of the Nuclotron. The time resolution of the TOF detector which used the described preamplifier was reached ˜42 ps.

  16. Measuring strain and stress distributions along rebar embedded in concrete using time-of-flight neutron diffraction

    NASA Astrophysics Data System (ADS)

    Suzuki, H.; Kusunoki, K.; Hatanaka, Y.; Mukai, T.; Tasai, A.; Kanematsu, M.; Kabayama, K.; Harjo, S.

    2014-02-01

    In modern society, architectural and civil engineering structures such as reinforced concrete buildings require high seismic performance to minimize the ‘megarisk’ exposed from urban earthquake hazards. In the reinforced concrete structures, the bond resistance between rebar and concrete is one important parameter for discussing its performance and it has been typically evaluated by measuring the strain distribution along the embedded rebar. Here, we present in-situ strain and stress measurements for the rebar in reinforced concrete using time-of-flight neutron diffraction as a novel alternative technique to typical strain gauges. It was demonstrated in this study that the three-dimensional deformation behavior of the embedded rebar in normal-strength concrete, cured in air, can be accurately measured under pull-out loading using time-of-flight neutron diffraction. Wider applications of neutron diffraction in the structural engineering field are expected for advanced understanding of actual phenomena on reinforced concrete structures.

  17. Laboratory and Field Characterizations of a Filter Inlet for Gases and AEROsols (FIGAERO) Collector Module for a Chemical Ionization Time-of-Flight Mass Spectrometer (CI-TOFMS) Instrument

    NASA Astrophysics Data System (ADS)

    Nowak, J. B.; Vogel, A.; Massoli, P.; Lambe, A. T.; Stark, H.; Kimmel, J.; Isaacman-VanWertz, G. A.; Kroll, J. H.; Canagaratna, M. R.; Worsnop, D. R.; Jayne, J. T.

    2015-12-01

    The Aerodyne Research, Inc. (ARI) Filter Inlet for Gases and AEROsols (FIGAERO) collector module is an add-on for Chemical Ionization Time-of-Flight Mass Spectrometer (CI-TOFMS) instruments. The FIGAERO enables simultaneous real-time chemical analysis of trace gases and particles in ambient air. The collector module described here is modelled after the University of Washington (UW) design of Lopez-Hilfikeret al., 2014. The collector module mounts directly to the front of the CI-TOFMS ion molecule reactor, replacing the standard gas phase inlet. Automated operation follows a two-step sequence alternating between gas and particle sampling. Gas and particle flows are sampled through separate inlet lines. Software provides automated control of the ARI FIGAERO and determines which inlet line is sampled into ion molecule reaction region. While in the gas phase measuring position particles are separately collected on a filter. After sufficient particle collection, heated clean nitrogen is passed over the filter to desorb the particles on the filter. The thermally desorbed material is then measured with the CI-TOFMS. Though conceptually similar, the ARI FIGAERO is mechanically different enough from the UW design that it requires its own performance assessment. Presented here is the characterization of the ARI FIGAERO collector module. The FIGAERO performance is assessed by using laboratory, chamber, and field data collected using iodide as the reagent ion to examine detection sensitivity, quantification limits, and time response. Lopez-Hilfiker et al., "A novel method for online analysis of gas and particle composition: description and evaluation of a Filter Inlet for Gases and AEROsols (FIGAERO)", Atmos. Meas. Tech., 7, 983-1001 (2014)

  18. Rapid Detection of OXA-48-Producing Enterobacteriaceae by Matrix-Assisted Laser Desorption Ionization−Time of Flight Mass Spectrometry

    PubMed Central

    Oviaño, Marina; Barba, Maria José; Fernández, Begoña; Ortega, Adriana; Aracil, Belén; Oteo, Jesús; Campos, José

    2015-01-01

    A rapid and sensitive (100%) matrix-assisted laser desorption ionization−time of flight mass spectrometry (MALDI-TOF MS) assay was developed to detect OXA-48-type producers, using 161 previously characterized clinical isolates. Ertapenem was monitored to detect carbapenem resistance, and temocillin was included in the assay as a marker for OXA-48-producers. Structural analysis of temocillin is described. Data are obtained within 60 min. PMID:26677247

  19. Molecule-Specific Imaging Analysis of Carcinogens in Breast Cancer Cells Using Time-of-Flight Secondary Ion Mass Spectrometry

    SciTech Connect

    Quong, J N; Knize, M G; Kulp, K S; Wu, K J

    2003-08-19

    Imaging time-of-flight secondary ion mass spectrometry (TOF-SIMS) is used to study the localization of heterocyclic amines in MCF7 line of human breast cancer cells. The detection sensitivities of a model rodent mutagen, 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP) were determined. Following an established criteria for the determination of status of freeze-fracture cells, the distribution of PhIP in the MCF7 cells are reported.

  20. MCP PMT with high time response and linear output current for neutron time-of-flight detectors

    NASA Astrophysics Data System (ADS)

    Dolotov, A. S.; Konovalov, P. I.; Nurtdinov, R. I.

    2016-09-01

    A microchannel plate (MCP) photomultiplier tube (PMT) with a subnanosecond time response and a high linear output current has been developed. PMT is designed for detection of weak pulses of radiation in UV-, visible and nearer-IR ranges and can be used in neutron time-of-flight (nTOF) detectors in experiments on laser compression of thermonuclear fuel. The results of measurements of MCP PMT main parameters are presented: photocathode spectral sensitivity, gain, maximum linear output current, and time response.

  1. Untangling the Formation Mechanisms of Biorelevant Molecules in the ISM with Photoionization Reflectron Time-of-Flight Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Förstel, Marko; Kaiser, Ralf I.

    2016-10-01

    Exploiting reflectron time of flight mass spectrometry coupled with single photon ionization of the subliming molecules (PI-ReTOF-MS) during the temperature programmed desorption (TPD) and combining these data with on line and in situ infrared spectroscopy (FTIR), a versatile experimental approach has been established to elucidate the formation pathways of complex organic molecules in interstellar analog ices upon interaction with ionizing radiation at astrophysically relevant temperatures as low as 5 K.

  2. Comparisons between co-axial and bi-axial optical systems for time-of-flight based laser scanners

    NASA Astrophysics Data System (ADS)

    Jang, Junhwan; Hwang, Sungui; Won, Bumsik; Park, Kyihwan

    2015-07-01

    In time-of-flight based laser scanners, measurable distance and accuracy are the most important parameters to determine performances. The optical system of the laser scanner should be optimally designed since a high intensity of measured signal increases the measurable distance and accuracy. Therefore, it is important to understand how the optical component layout affects the laser scanner performances. Optical component design for co-axial and bi-axial mechanisms are considered in the paper.

  3. Carrier mobility in rubrene-doped 4-cyano-4'-pentylbiphenyl studied by the time-of-flight method

    NASA Astrophysics Data System (ADS)

    Honma, Michinori; Nose, Toshiaki

    2013-09-01

    We have investigated the transient photocurrent of rubrene-doped nematic liquid crystal using a time-of-flight examination. Drift mobilities on the order of 10-6 cm2/V s were obtained for both positive and negative carriers. The minimal dependence of the rubrene concentration on the drift mobility is indicative of the ionic conduction as carrier transport process. The product of the drift mobility and the viscosity obeys the Walden rule, further supporting the ionic carrier transport process.

  4. Implementation of TTIK method and time of flight for resonance reaction studies at heavy ion accelerator DC-60

    NASA Astrophysics Data System (ADS)

    Nurmukhanbetova, A. K.; Goldberg, V. Z.; Nauruzbayev, D. K.; Rogachev, G. V.; Golovkov, M. S.; Mynbayev, N. A.; Artemov, S.; Karakhodjaev, A.; Kuterbekov, K.; Rakhymzhanov, A.; Berdibek, Zh.; Ivanov, I.; Tikhonov, A.; Zherebchevsky, V. I.; Torilov, S. Yu.; Tribble, R. E.

    2017-03-01

    To study resonance reactions of heavy ions at low energy we have combined the Thick Target Inverse Kinematics Method (TTIK) with Time of Flight method (TF). We used extended target and TF to resolve the identification problems of various possible nuclear processes inherent to the simplest popular version of TTIK. Investigations of the 15N interaction with hydrogen and helium gas targets by using this new approach are presented.

  5. High mass resolution isochronous time-of-flight spectrograph for three-dimensional space plasma measurements (abstract)

    SciTech Connect

    Moebius, E. ); Bochsler, P. ); Ghielmetti, A.G. ); Hamilton, D.C. )

    1990-10-01

    By combining a toroidal electrostatic analyzer with a novel cylindrically symmetric isochronous time-of-flight mass spectrometer, we have developed an instrument that simultaneously determines the three-dimensional distribution function of ions and differentiates species. The ion mass is determined to high resolution ({ital M}/{Delta}{ital M}{gt}50) from the time of flight within a harmonic field configuration defined by hyperboloid equipotential surfaces. A second conventional time-of-flight channel makes use of particles leaving the thin entrance foil as neutrals. An additional solid state detector in which the neutrals are stopped allows the total energy and thereby the ionic charge of the incident ions to be determined as well. Information from the neutral and the ion channels can be combined to determine the total mass of an incident molecular ion and the mass of one atomic fragment. This also removes the ambiguity between molecular ions and isotopic species of the same mass. A laboratory prototype has been used to demonstrate the feasibility of the principle of operation.

  6. High mass resolution time of flight mass spectrometer for measuring products in heterogeneous catalysis in highly sensitive microreactors

    SciTech Connect

    Andersen, T.; Jensen, R.; Christensen, M. K.; Chorkendorff, I.; Pedersen, T.; Hansen, O.

    2012-07-15

    We demonstrate a combined microreactor and time of flight system for testing and characterization of heterogeneous catalysts with high resolution mass spectrometry and high sensitivity. Catalyst testing is performed in silicon-based microreactors which have high sensitivity and fast thermal response. Gas analysis is performed with a time of flight mass spectrometer with a modified nude Bayard-Alpert ionization gauge as gas ionization source. The mass resolution of the time of flight mass spectrometer using the ion gauge as ionization source is estimated to m/{Delta}m > 2500. The system design is superior to conventional batch and flow reactors with accompanying product detection by quadrupole mass spectrometry or gas chromatography not only due to the high sensitivity, fast temperature response, high mass resolution, and fast acquisition time of mass spectra but it also allows wide mass range (0-5000 amu in the current configuration). As a demonstration of the system performance we present data from ammonia oxidation on a Pt thin film showing resolved spectra of OH and NH{sub 3}.

  7. Calibration of time-of-flight cameras for accurate intraoperative surface reconstruction

    SciTech Connect

    Mersmann, Sven; Seitel, Alexander; Maier-Hein, Lena; Erz, Michael; Jähne, Bernd; Nickel, Felix; Mieth, Markus; Mehrabi, Arianeb

    2013-08-15

    Purpose: In image-guided surgery (IGS) intraoperative image acquisition of tissue shape, motion, and morphology is one of the main challenges. Recently, time-of-flight (ToF) cameras have emerged as a new means for fast range image acquisition that can be used for multimodal registration of the patient anatomy during surgery. The major drawbacks of ToF cameras are systematic errors in the image acquisition technique that compromise the quality of the measured range images. In this paper, we propose a calibration concept that, for the first time, accounts for all known systematic errors affecting the quality of ToF range images. Laboratory and in vitro experiments assess its performance in the context of IGS.Methods: For calibration the camera-related error sources depending on the sensor, the sensor temperature and the set integration time are corrected first, followed by the scene-specific errors, which are modeled as function of the measured distance, the amplitude and the radial distance to the principal point of the camera. Accounting for the high accuracy demands in IGS, we use a custom-made calibration device to provide reference distance data, the cameras are calibrated too. To evaluate the mitigation of the error, the remaining residual error after ToF depth calibration was compared with that arising from using the manufacturer routines for several state-of-the-art ToF cameras. The accuracy of reconstructed ToF surfaces was investigated after multimodal registration with computed tomography (CT) data of liver models by assessment of the target registration error (TRE) of markers introduced in the livers.Results: For the inspected distance range of up to 2 m, our calibration approach yielded a mean residual error to reference data ranging from 1.5 ± 4.3 mm for the best camera to 7.2 ± 11.0 mm. When compared to the data obtained from the manufacturer routines, the residual error was reduced by at least 78% from worst calibration result to most accurate

  8. Ion storage techniques and time-of-flight mass spectrometry in physical forensic science

    SciTech Connect

    Chambers, D M; Grace, L I

    2000-06-27

    /neutral collision conditions without regard to perturbing ion secular motion. This permits overfilling of the IS and the use of air as a collisional damping gas with little effect on resolution and mass accuracy. A subsequent advantage of using air as a collisional damping gas is that it enhances ionization efficiency by providing a mechanism for chemical ionization. In addition to ion storage, the ion trap can be operated to deliver an ion packet with a spatial and kinetic energy distribution well suited for time-of-flight analysis. This mode of operation enhances sensitivity and resolution permitting the TOF-MS analyzer to be used effectively for real-time air monitoring. Among the different changes to trap operation needed for optimal operation, those modifications that minimize dispersion of the ion packet during extraction have the greatest effect on performance. Together these modifications, which include (1) phase synchronization, (2) RF clamping and (3) bipolar extraction, permit resolution of up to 1600 m/{Delta}m at FWHM and detection into the low ppb range for VOCs. Sensitivity for semi-VOCs is significantly lower and is attributed to adsorption loss in the IS envelop. We are currently investigating solutions to this limitation.

  9. NOTE: LaBr3:Ce and SiPMs for time-of-flight PET: achieving 100 ps coincidence resolving time

    NASA Astrophysics Data System (ADS)

    Schaart, Dennis R.; Seifert, Stefan; Vinke, Ruud; van Dam, Herman T.; Dendooven, Peter; Löhner, Herbert; Beekman, Freek J.

    2010-04-01

    The use of time-of-flight (TOF) information in positron emission tomography (PET) enables significant improvement in image noise properties and, therefore, lesion detection. Silicon photomultipliers (SiPMs) are solid-state photosensors that have several advantages over photomultiplier tubes (PMTs). SiPMs are small, essentially transparent to 511 keV gamma rays and insensitive to magnetic fields. This enables novel detector designs aimed at e.g. compactness, high resolution, depth-of-interaction (DOI) correction and MRI compatibility. The goal of the present work is to study the timing performance of SiPMs in combination with LaBr3:Ce(5%), a relatively new scintillator with promising characteristics for TOF-PET. Measurements were performed with two, bare, 3 mm × 3 mm × 5 mm LaBr3:Ce(5%) crystals, each coupled to a 3 mm × 3 mm SiPM. Using a 22Na point source placed at various positions in between the two detectors, a coincidence resolving time (CRT) of ~100 ps FWHM for 511 keV annihilation photon pairs was achieved, corresponding to a TOF positioning resolution of ~15 mm FWHM. At the same time, pulse height spectra with well-resolved full-energy peaks were obtained. To our knowledge this is the best CRT reported for SiPM-based scintillation detectors to date. It is concluded that SiPM-based scintillation detectors can provide timing resolutions at least as good as detectors based on PMTs.

  10. A miniaturised electron ionisation time-of-flight mass spectrometer that uses a unique helium ion removal pulsing technique specifically for gas analysis.

    PubMed

    Qing, Jiang; Huang, Zhengxu; Zhang, Yan; Zhu, Hui; Tan, Guobin; Gao, Wei; Yang, Peng-yuan

    2013-06-21

    A miniaturised reflectron time-of-flight mass spectrometer combined with an electron ionisation ion source has been developed for the analysis of gases. An entirely new helium ion removal pulsing technique in this mass spectrometer is used to achieve an improved performance for the first time. The helium carrier gas, which enters into the source along with the gaseous sample, is simultaneously ionised and then orthogonally introduced into the time-of-fight mass analyser. Once the relatively light helium ions in the ion packet become extremely close to the reflectron plate (B-plate for short in this article), a modulated pulse is instantaneously applied on the B-plate and a negative reflectron voltage is set to the B-plate and lasts for a very short period, during which all the helium ions are directly bumped into the B-plate and subsequently removed. The helium ion removal pulsing technique can efficiently avoid saturation of the micro-channel plate caused by too many helium ions. A compact and durable instrument is designed, which has a mass resolving resolution greater than 400 FWHM for online gas analysis. The technology may also be further developed to remove other ions for TOF mass spectrometry.

  11. Optimizing a neutron-beam focusing device for the direct geometry time-of-flight spectrometer TOFTOF at the FRM II reactor source

    NASA Astrophysics Data System (ADS)

    Rasmussen, N. G.; Simeoni, G. G.; Lefmann, K.

    2016-04-01

    A dedicated beam-focusing device has been designed for the direct geometry thermal-cold neutron time-of-flight spectrometer TOFTOF at the neutron facility FRM II (Garching, Germany). The prototype, based on the compressed Archimedes' mirror concept, benefits from the adaptive-optics technology (adjustable supermirror curvature) and the compact size (only 0.5 m long). We have simulated the neutron transport across the entire guide system. We present a detailed computer characterization of the existing device, along with the study of the factors mostly influencing the future improvement. We have optimized the simulated prototype as a function of the neutron wavelength, accounting also for all relevant features of a real instrument like the non-reflecting side edges. The results confirm the "chromatic" displacement of the focal point (flux density maximum) at fixed supermirror curvature, and the ability of a variable curvature to keep the focal point at the sample position. Our simulations are in excellent agreement with theoretical predictions and the experimentally measured beam profile. With respect to the possibility of a further upgrade, we find that supermirror coatings with m-values higher than 3.5 would have only marginal influence on the optimal behaviour, whereas comparable spectrometers could take advantage of longer focusing segments, with particular impact for the thermal region of the neutron spectrum.

  12. Formation and Processing of Organic Aerosols Measured by a Time of Flight Aerosol Mass Spectrometer during TexAQS/GoMACCS 2006

    NASA Astrophysics Data System (ADS)

    Bahreini, R.; Middlebrook, A. M.; Decarlo, P. F.; Denlea, E.; Jimenez, J. L.; Brock, C. A.; Degouw, J. A.; Flocke, F.; Gallar, C.; Holloway, J. S.; Neuman, J. A.; Ryerson, T. B.; Schwarz, J. P.; Spackman, J. R.; Trainer, M. K.; Warneke, C.; Wollny, A. G.; Zhang, W.; Fehsenfeld, F. C.

    2007-12-01

    Formation of particulate matter is common in areas with high emissions of volatile organic compounds (VOCs), NOx, and SO2. These particles have lifetimes of days to weeks, and thus can have both local and regional effects on visibility, air quality, and human health as well as direct and indirect effects on climate. During TexAQS 2006, mass concentrations of non-refractory inorganic species (sulfate, ammonium, and nitrate) and total organics in submicron aerosols were measured by a Compact Time of Flight Aerosol Mass Spectrometer (C-ToF-AMS) onboard the NOAA WP-3D aircraft. In this presentation, we analyze composition changes of organic aerosols in different air masses. We examine organic mass spectra along with simultaneous measurements of VOCs and their oxidation products in order to determine the contribution of anthropogenic and biogenic sources to the aerosol organic mass. These measurements were performed in plumes intercepted during the daytime north of Houston where large isoprene emissions were observed. Furthermore, the fresh hydrocarbon-like (HOA) and processed oxygenated-like organics (OOA) fractions of the total organic aerosol mass in several plumes transected during daytime and nighttime are presented and compared. We will also discuss differences in correlations between organic aerosol composition markers and primary or secondary gas-phase species in different plumes.

  13. Hybrid quadrupole mass filter/quadrupole ion trap/time-of-flight-mass spectrometer for infrared multiple photon dissociation spectroscopy of mass-selected ions

    SciTech Connect

    Gulyuz, Kerim; Stedwell, Corey N.; Wang Da; Polfer, Nick C.

    2011-05-15

    We present a laboratory-constructed mass spectrometer optimized for recording infrared multiple photon dissociation (IRMPD) spectra of mass-selected ions using a benchtop tunable infrared optical parametric oscillator/amplifier (OPO/A). The instrument is equipped with two ionization sources, an electrospray ionization source, as well as an electron ionization source for troubleshooting. This hybrid mass spectrometer is composed of a quadrupole mass filter for mass selection, a reduced pressure ({approx}10{sup -5} Torr) quadrupole ion trap (QIT) for OPO irradiation, and a reflectron time-of-flight drift tube for detecting the remaining precursor and photofragment ions. A helium gas pulse is introduced into the QIT to temporarily increase the pressure and hence enhance the trapping efficiency of axially injected ions. After a brief pump-down delay, the compact ion cloud is subjected to the focused output from the continuous wave OPO. In a recent study, we implemented this setup in the study of protonated tryptophan, TrpH{sup +}, as well as collision-induced dissociation products of this protonated amino acid [W. K. Mino, Jr., K. Gulyuz, D. Wang, C. N. Stedwell, and N. C. Polfer, J. Phys. Chem. Lett. 2, 299 (2011)]. Here, we give a more detailed account on the figures of merit of such IRMPD experiments. The appreciable photodissociation yields in these measurements demonstrate that IRMPD spectroscopy of covalently bound ions can be routinely carried out using benchtop OPO setups.

  14. Wind tunnel validation of AeroDyn within LIFES50+ project: imposed Surge and Pitch tests

    NASA Astrophysics Data System (ADS)

    Bayati, I.; Belloli, M.; Bernini, L.; Zasso, A.

    2016-09-01

    This paper presents the first set of results of the steady and unsteady wind tunnel tests, performed at Politecnico di Milano wind tunnel, on a 1/75 rigid scale model of the DTU 10 MW wind turbine, within the LIFES50+ project. The aim of these tests is the validation of the open source code AeroDyn developed at NREL. Numerical and experimental steady results are compared in terms of thrust and torque coefficients, showing good agreement, as well as for unsteady measurements gathered with a 2 degree-of-freedom test rig, capable of imposing the displacements at the base of the model, and providing the surge and pitch motion of the floating offshore wind turbine (FOWT) scale model. The measurements of the unsteady test configuration are compared with AeroDyn/Dynin module results, implementing the generalized dynamic wake (GDW) model. Numerical and experimental comparison showed similar behaviours in terms of non linear hysteresis, however some discrepancies are herein reported and need further data analysis and interpretations about the aerodynamic integral quantities, with a special attention to the physics of the unsteady phenomenon.

  15. Duty cycle and modulation efficiency of two-channel Hadamard transform time-of-flight mass spectrometry.

    PubMed

    Yoon, Oh Kyu; Zuleta, Ignacio A; Kimmel, Joel R; Robbins, Matthew D; Zare, Richard N

    2005-11-01

    Hadamard transform time-of-flight mass spectrometry (HT-TOFMS) is based on the pseudorandom gating of ion packets into a time-of-flight mass-to-charge analyzer. In its typical implementation, the technique is able to monitor continuous ion sources with a 50% duty cycle, independent of all other figures of merit. Recently, we have demonstrated that the duty cycle can be extended to 100% using patterned, two-channel detection. Two-channel HT-TOFMS involves the simultaneous optimization of paired one-channel experiments and imposes more stringent conditions to achieve high-quality spectra. An ion modulation device, known as Bradbury-Nielson Gate (BNG), is central to HT-TOFMS. It is an ideal deflection plate, capable of transmitting or deflecting an ion beam according to a known binary sequence without changing the times-of-flight of the ions. Analytical equations are derived that accurately describe the ion modulation process of the BNG as confirmed by good agreement with SimIon simulations and ion beam imaging experiments. From these expressions, the duty cycle and ion modulation efficiency were calculated for various BNG parameters, ion beam characteristics, and detector dimensions, which permit the optimum conditions to be chosen for the two-channel experiment. We conclude that the outer detector should be three times the maximum deflection angle to detect all deflected ions (100% duty cycle) and that the difference between the modulated ion counts in the sequence elements 0 and 1 should be maximized to achieve high modulation efficiency. This condition is best achieved by tight focusing of the ion beam in the center of the inner detector. When both channels are optimized, the two-channel advantage can be exploited to achieve a further improvement over a single-channel experiment.

  16. Time of flight mass spectrometry applied to the liquid chromatographic analysis of pesticides in water and food.

    PubMed

    Lacorte, Sílvia; Fernandez-Alba, Amadeo R

    2006-01-01

    Liquid chromatography coupled to mass spectrometry (LC-MS) is an excellent technique to determine trace levels of polar and thermolabile pesticides and their degradation products in complex matrices. LC-MS can be equipped with several mass analyzers, each of which provides unique features capable to identify, quantify, and resolve ambiguities by selecting appropriate ionization and acquisition parameters. We discuss in this review the use of LC coupled to (quadrupole) time-of-flight mass spectrometry (LC-(Q)ToF-MS) to determine the presence of target and non-target pesticides in water and food. This technique is characterized by operating at a resolving power of 10,000 or more. Therefore, it gives accurate masses for both parent and fragment ions and enables the measurement of the elemental formula of a compound achieving compound identification. In addition, the combination of quadrupole-ToF permits tandem mass spectrometry, provides more structural information, and enhances selectivity. The purpose of this article is to provide an overview on the state of art and applicability of liquid chromatography time-of-flight mass spectrometry (LC-ToF-MS), and liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QToF-MS) for the analysis of pesticides in environmental matrices and food. The performance of such techniques is depicted in terms of accurate mass measurement, fragmentation, and selectivity. The final section is devoted to describing the applicability of LC-(Q)ToF-MS to routine analysis of pesticides in food matrices, indicating those operational conditions and criteria used to screen, quantify, and identify target and "suspected" pesticides and their degradation products in water, fruits, and vegetables. The potential and future trends as well as limitations of LC-(Q)ToF-MS for pesticide monitoring are highlighted.

  17. [Special application of matrix-assisted laser desorption ionization time-of-flight mass spectrometry in clinical microbiological diagnostics].

    PubMed

    Nagy, Erzsébet; Abrók, Marianna; Bartha, Noémi; Bereczki, László; Juhász, Emese; Kardos, Gábor; Kristóf, Katalin; Miszti, Cecilia; Urbán, Edit

    2014-09-21

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry as a new possibility for rapid identification of bacteria and fungi revolutionized the clinical microbiological diagnostics. It has an extreme importance in the routine microbiological laboratories, as identification of the pathogenic species rapidly will influence antibiotic selection before the final determination of antibiotic resistance of the isolate. The classical methods for identification of bacteria or fungi, based on biochemical tests, are influenced by many environmental factors. The matrix-assisted laser desorption ionization time-of-flight mass spectrometry is a rapid method which is able to identify a great variety of the isolated bacteria and fungi based on the composition of conserved ribosomal proteins. Recently several other applications of the method have also been investigated such as direct identification of pathogens from the positive blood cultures. There are possibilities to identify bacteria from the urine samples in urinary tract infection or from other sterile body fluids. Using selective enrichment broth Salmonella sp from the stool samples can be identified more rapidly, too. The extended spectrum beta-lactamase or carbapenemase production of the isolated bacteria can be also detected by this method helping the antibiotic selection in some cases. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry based methods are suitable to investigate changes in deoxyribonucleic acid or ribonucleic acid, to carry out rapid antibiotic resistance determination or other proteomic analysis. The aim of this paper is to give an overview about present possibilities of using this technique in the clinical microbiological routine procedures.

  18. Design Study for a Multi-Reflection Time-of-Flight Mass Spectrograph for Very Short Lived Nuclei

    NASA Astrophysics Data System (ADS)

    Yoon, Jin Woo; Park, Young-Ho; Im, Kang-Bin; Kim, Gi Dong; Kim, Yong Kyun

    The multi-reflection time-of-flight mass spectrometer (MR-TOF-MS) has been designed for the high precision mass measurement system in RAON accelerator facility, which will be constructed in Korea. Mirror-electrode potentials were numerically optimized by Nelder-Mead algorithm. The temporal spread and the mass-resolving power were calculated for the 132Sn+ ions with an energy spread of 20 eV and an emittance of 3 π mm mrad; the mass resolving power over 105 was achieved. MR-TOF-MS will be used for the isobar separation and the mass measurement for very short-lived isotopes.

  19. Characterization of neutron scatter for the 25-m neutron time of flight detector at the Z Accelerator

    NASA Astrophysics Data System (ADS)

    Norris, Edward; Hahn, Kelly; Chandler, Gordon; Ruiz, Carlos; Styron, Jedediah; Cooper, Gary; Jones, Brent; Torres, Jose; Spencer, Decker; Nelson, Alan

    2016-10-01

    We are investigating neutron scattering effects using Monte Carlo simulations for neutron time of flight (NTOF) detectors fielded at the Z Accelerator at Sandia National Laboratories. For the radial NTOF detector at 25 m, a large scatter distribution is observed during and after primary DD neutron signals produced during inertial-confinement fusion experiments which obfuscates inference of quantities such as ion temperature, yield, and liner areal density. We present comparisons of measurements with simulation results. We also propose improvements to this line-of-sight. Sandia is sponsored by the U.S. DOE's NNSA under contract DE-AC04-94AL85000.

  20. A dedicated hardware architecture for data acquisition and processing in a time-of-flight emission tomography system (Super PETT)

    SciTech Connect

    Holmes, T.J.; Blaine, G.J.; Fiche, D.C.; Hitchens, R.E.; Snyder, D.L.

    1983-02-01

    The authors present the architecture, implementation and performance aspects of a dedicated processor for use in Super-PETT. The micro-coded machine accepts event data from the acquisition circuitry and constructs in real time any of three pre-image types, including time-of-flight arrays. Pre-images are later backloaded to perform high speed reconstructions. One such processor is assigned to each image slice of the Super-PETT. Event rates and processing times are given for various application modalities.

  1. Current status of matrix-assisted laser desorption ionisation-time of flight mass spectrometry in the clinical microbiology laboratory.

    PubMed

    Kok, Jen; Chen, Sharon C A; Dwyer, Dominic E; Iredell, Jonathan R

    2013-01-01

    The integration of matrix-assisted laser desorption ionisation-time of flight mass spectrometry (MALDI-TOF MS) into many clinical microbiology laboratories has revolutionised routine pathogen identification. MALDI-TOF MS complements and has good potential to replace existing phenotypic identification methods. Results are available in a more clinically relevant timeframe, particularly in bacteraemic septic shock. Novel applications include strain typing and the detection of antimicrobial resistance, but these are not widely used. This review discusses the technical aspects, current applications, and limitations of MALDI-TOF MS.

  2. Time-of-flight diffractometer with multiple pulse overlap - an example for the application of modern tools for instrument design

    SciTech Connect

    Stuhr, U.; Bauer, G.S.; Wagner, W.

    1997-09-01

    A Time-of-Flight Diffractometer with high pulse rates, allowing multiple frame overlap, is a completely novel design of an instrument dedicated for high resolution strain-field mapping. We elaborated a detailed concept of this instrument applying analytical calculations and Monte Carlo computer simulations. Having established the instrument concept, the computer simulations will now be extended to optimize the total performance of the instrument. To illustrate the necessity and possibilities of applying modem tools for instrument design, we describe, as an example, the different steps towards the development of the detailed design of this instrument, which we intend to build at the Swiss spallation. source SINQ in the near future.

  3. Critical moments in time: reflections on the development of orthogonal acceleration time-of-flight mass spectrometry.

    PubMed

    Sheil, Margaret M

    2012-08-01

    This paper reflects on the historical development of orthogonal acceleration time-of-flight analyzers that have been used routinely for high sensitivity analyses of biological molecules for more than a decade. In particular, the role of the late Michael Guilhaus from the University of New South Wales in Australia is highlighted. This account shows that like most advances in science, successful commercialization of new technology is not straightforward and is often the result of critical contributions of different people and organizations at different points in time.

  4. A gas ionisation detector in the axial (Bragg) geometry used for the time-of-flight elastic recoil detection analysis

    SciTech Connect

    Siketić, Zdravko; Skukan, Natko; Bogdanović Radović, Iva

    2015-08-15

    In this paper, time-of-flight elastic recoil detection analysis spectrometer with a newly constructed gas ionization detector for energy detection is presented. The detector is designed in the axial (Bragg) geometry with a 3 × 3 array of 50 nm thick Si{sub 3}N{sub 4} membranes as an entrance window. 40 mbar isobutane gas was sufficient to stop a 30 MeV primary iodine beam as well as all recoils in the detector volume. Spectrometer and detector performances were determined showing significant improvement in the mass and energy resolution, respectively, comparing to the spectrometer with a standard silicon particle detector for an energy measurement.

  5. A gas ionisation detector in the axial (Bragg) geometry used for the time-of-flight elastic recoil detection analysis.

    PubMed

    Siketić, Zdravko; Skukan, Natko; Bogdanović Radović, Iva

    2015-08-01

    In this paper, time-of-flight elastic recoil detection analysis spectrometer with a newly constructed gas ionization detector for energy detection is presented. The detector is designed in the axial (Bragg) geometry with a 3 × 3 array of 50 nm thick Si3N4 membranes as an entrance window. 40 mbar isobutane gas was sufficient to stop a 30 MeV primary iodine beam as well as all recoils in the detector volume. Spectrometer and detector performances were determined showing significant improvement in the mass and energy resolution, respectively, comparing to the spectrometer with a standard silicon particle detector for an energy measurement.

  6. Determination of impurities in uranium matrices by time-of-flight ICP-MS using matrix-matched method

    SciTech Connect

    Buerger, Stefan; Riciputi, Lee R; Bostick, Debra A

    2007-01-01

    The analysis of impurities in uranium matrices is performed in a variety of fields, e.g. for quality control in the production stream converting uranium ores to fuels, as element signatures in nuclear forensics and safeguards, and for non-proliferation control. We have investigated the capabilities of time-of-flight ICP-MS for the analysis of impurities in uranium matrices using a matrix-matched method. The method was applied to the New Brunswick Laboratory CRM 124(1-7) series. For the seven certified reference materials, an overall precision and accuracy of approximately 5% and 14%, respectively, were obtained for 18 analyzed elements.

  7. Measurements of the plasma density in the FTU tokamak by a pulsed time-of-flight X-wave refractometer

    NASA Astrophysics Data System (ADS)

    Petrov, V. G.; Petrov, A. A.; Malyshev, A. Yu.; de Benedetti, M.; Tudisco, O.

    2008-01-01

    On-line control over the plasma density in tokamaks (especially, in long-term discharges) requires reliable measurements of the averaged plasma density. For this purpose, a new method of density measurements—a pulsed time-of-flight plasma refractometry—was developed and tested in the T-11M tokamak. This method allows one to determine the averaged density from the measured time delay of nanosecond microwave pulses propagating through the plasma. For an O-wave, the measured time delay is proportional to the line-averaged density and is independent of the density profile ( f≫ f p ) τo ≈ k o tfrac{1} {{f^2 }}mathop int limits_l N( x dx. A similar formula is valid for an X-wave: τX = ≈ k x tfrac{{f^2 + f_c^2 }} {{(f^2 - f_c^2 )^2 }}mathop int limits_l N( x) dx. Here, f is the frequency of the probing wave, f p is the plasma frequency, l= 4 a is the path length for two-pass probing in the equatorial plane, a is the plasma minor radius, k O and k X are numerical factors, f c is the electron-cyclotron frequency at the axis of the plasma column, and f p ≫ f c , f. Measurements of the time delay provide the same information as plasma interferometry, though they do no employ the effect of interference. When the conditions f p ≫ f c , f are not satisfied, the measured time delay depends on the shape of the density profile. In this case, in order to determine the average density regardless of the density profile, it is necessary to perform simultaneous measurements at several probing frequencies in order to determine the average density. In ITER ( Bt ˜ 5T), a spectral window between the lower and upper cutoff frequencies in the range of 50-100 GHz can be used for pulsed time-of-flight X-wave refractometry. This appreciably simplifies the diagnostics and eliminates the problem of the first mirror. In this paper, the first results obtained in the FTU tokamak with a prototype of the ITER pulsed time-of-flight refractometer are presented. The geometry and layout of

  8. Few layer graphene matrix for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

    PubMed

    Cho, Donghyun; Hong, Sangsu; Shim, Sangdeok

    2013-08-01

    We present the employment of few layer graphene (FLG) as a matrix for the analysis of low molecular weight polymeric compounds using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The practicality of FLG as a matrix for MALDI experiments is demonstrated by analyzing low molecular weight polymers, polar polyethylene glycol (PEG) of 1000 Da and nonpolar polymethylmethacrylate (PMMA) of 650 Da. The high quality MS spectra without low-mass interference signals without any further sampling procedure were acquired.

  9. Application of the Monte Carlo methods and variational procedure for optimizing time-of-flight neutron diffractometer characteristics

    NASA Astrophysics Data System (ADS)

    Khrushchinsky, A. A.; Kuten, S. A.; Viarenich, K. A.; Speransky, P. A.

    2016-05-01

    Based on variational calculus, a procedure for the optimal approximation of detector surface of the time-of-flight neutron diffractometer has been suggested. The exact solution for a point sample and zero thickness detector has been obtained. Using the shape of the detector surface, an optimized Monte Carlo simulation has been performed for the parameters of the spectrometer depending on the sample size and detector thickness, its azimuthal and Bragg's angular dimensions, and taking into account the neutron absorption in the sample and detector.

  10. SYNCHROTRON RADIATION, FREE ELECTRON LASER, APPLICATION OF NUCLEAR TECHNOLOGY, ETC. Physical design of positronium time of flight spectroscopy apparatus

    NASA Astrophysics Data System (ADS)

    Jiang, Xiao-Pan; Zhang, Zi-Liang; Qin, Xiu-Bo; Yu, Run-Sheng; Wang, Bao-Yi

    2010-12-01

    Positronium time of flight spectroscopy (Ps-TOF) is an effective technique for porous material research. It has advantages over other techniques for analyzing the porosity and pore tortuosity of materials. This paper describes a design for Ps-TOF apparatus based on the Beijing intense slow positron beam, supplying a new material characterization technique. In order to improve the time resolution and increase the count rate of the apparatus, the detector system is optimized. For 3 eV o-Ps, the time broadening is 7.66 ns and the count rate is 3 cps after correction.

  11. Ion time-of-flight determinations of doubly to singly ionized mercury ion ratios from a mercury electron bombardment discharge

    NASA Technical Reports Server (NTRS)

    Sellen, J. M., Jr.; Kemp, R. F.; Hall, D. F.

    1973-01-01

    Doubly to singly charged mercury ion ratios in electron bombardment ion thruster exhaust beams have been determined as functions of bombardment discharge potential, thrust beam current, thrust beam radial position, acceleration-deceleration voltage ratio, and propellant utilization fraction. A mathematical model for two-step ionization processes has been derived, and calculated ion ratios are compared to observed ratios. Production of Hg(++) appears to result primarily from sequential ionization of Hg(+) in the discharge. Experimental and analytical results are presented, and design, construction, and operation features of an electrostatic deflection ion time-of-flight analyzer for the determination of the above-mentioned ratios are reviewed.

  12. Classification of stevia sweeteners in soft drinks using liquid chromatography and time-of-flight mass spectrometry.

    PubMed

    Kakigi, Y; Suzuki, T; Icho, T; Uyama, A; Mochizuki, N

    2013-01-01

    The aim of this study was to develop a comprehensive analytical method for the characterisation of stevia sweeteners in soft drinks. By using LC and time-of-flight MS, we detected 30 steviol glycosides from nine stevia sweeteners. The mass spectral data of these compounds were applied to the analysis to determine steviol glycosides in nine soft drinks. On the basis of chromatographic data and principal-component analysis, these soft drinks were classified into three groups, and the soft drinks of each group, respectively, contained high-rebaudioside A extract, normal stevia extract or alfa-glucosyltransferase-treated stevia extract.

  13. Non-destructive Analysis of Material Detachments from Polychromatically Glazed Terracotta Artwork by THz Time-of-Flight Spectroscopy

    NASA Astrophysics Data System (ADS)

    Krügener, Kirsti; Busch, Stefan F.; Soltani, Amin; Castro-Camus, Enrique; Koch, Martin; Viöl, Wolfgang

    2017-04-01

    The damage caused by the environment to exposed glazed terracotta objects is usually not externally visible. For instance, the detachment of the glaze owing to subsurface crack formation or whole cavities in the area of the terracotta cannot be located visually. In this article, we demonstrate that terahertz time-of-flight spectroscopy is suitable to locate and measure the air gaps under the glaze detachments which could only be done by X-ray axial tomography before. This tool will be very useful to guide the restoration process, particularly for pieces that are still attached to buildings or other structures that cannot be transported to a tomography facility.

  14. Semiquantitative multielemental analysis of biological samples by a laser ionization orthogonal time-of-flight mass spectrometer.

    PubMed

    Chen, Lizhi; Lin, Lin; Yu, Quan; Yan, Xiaomei; Hang, Wei; He, Jian; Huang, Benli

    2009-07-01

    Semiquantitative multielemental analyses of biological samples (tea leaf standard, Laminaria japonica, and pig skin) were demonstrated with a newly developed laser ionization orthogonal time-of-flight mass spectrometer (LI-O-TOFMS). The sample was directly ablated and ionized with high irradiance after simple sample preparation. Relative sensitivity coefficients (RSC) were calculated and evaluated for sensitivity differences. Due to the employment of a collisional cooling device and the orthogonal geometry of the TOF system, high resolving power can be obtained, such that elemental peaks and interferential peaks with the same nominal mass can be distinguished. The detection limit of microg g(-1) levels can be commonly achieved for elemental determination.

  15. Non-destructive Analysis of Material Detachments from Polychromatically Glazed Terracotta Artwork by THz Time-of-Flight Spectroscopy

    NASA Astrophysics Data System (ADS)

    Krügener, Kirsti; Busch, Stefan F.; Soltani, Amin; Castro-Camus, Enrique; Koch, Martin; Viöl, Wolfgang

    2016-11-01

    The damage caused by the environment to exposed glazed terracotta objects is usually not externally visible. For instance, the detachment of the glaze owing to subsurface crack formation or whole cavities in the area of the terracotta cannot be located visually. In this article, we demonstrate that terahertz time-of-flight spectroscopy is suitable to locate and measure the air gaps under the glaze detachments which could only be done by X-ray axial tomography before. This tool will be very useful to guide the restoration process, particularly for pieces that are still attached to buildings or other structures that cannot be transported to a tomography facility.

  16. Design of a magnetic shielding system for the time of flight enhanced diagnostics neutron spectrometer at Experimental Advanced Superconducting Tokamak.

    PubMed

    Cui, Z Q; Chen, Z J; Xie, X F; Peng, X Y; Hu, Z M; Du, T F; Ge, L J; Zhang, X; Yuan, X; Xia, Z W; Hu, L Q; Zhong, G Q; Lin, S Y; Wan, B N; Fan, T S; Chen, J X; Li, X Q; Zhang, G H

    2014-11-01

    The novel neutron spectrometer TOFED (Time of Flight Enhanced Diagnostics), comprising 90 individual photomultiplier tubes coupled with 85 plastic scintillation detectors through light guides, has been constructed and installed at Experimental Advanced Superconducting Tokamak. A dedicated magnetic shielding system has been constructed for TOFED, and is designed to guarantee the normal operation of photomultiplier tubes in the stray magnetic field leaking from the tokamak device. Experimental measurements and numerical simulations carried out employing the finite element method are combined to optimize the design of the magnetic shielding system. The system allows detectors to work properly in an external magnetic field of 200 G.

  17. [Separation and identification of beta-casein from Chinese human milk by ion exchange chromatography-matrix-assisted laser desorption/ionization time of flight/time of flight mass spectrometry].

    PubMed

    Huang, Yu; Ren, Haowei; Liu, Biao; Liu, Ning; Li, Meng; Wang, Dongmao

    2013-05-01

    The selective precipitation of whole casein from skimmed milk was achieved by the addition of calcium salt under acidic pH. The effects of pH, centrifugal force and final concentration of CaCl2 on the separation of casein were studied by measuring the purity of final products using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). The results showed that casein with the highest purity could be obtained with the pH of 4.3, the centrifugal force of 10 400 g and the final concentration of CaCl2 of 60 mmol/L. The casein was processed with DEAE anion exchange chromatography and three peaks were obtained. Then the third peak (peak III) was identified with Western-Blot method and matrix-assisted laser desorption/ionization time of flight/time of flight mass spectrometry (MALDI-TOF/TOF MS). The identification of Western-Blot showed that peak III can combine with the specificity of human milk beta-casein antibody, and it is proved to be human milk beta-casein. The fingerprints of peak III were nalyzed by Mascot searching, and the sequence coverage was 50%, further supporting it is human milk beta-casein. In conclusion, an effective method to obtain human milk beta-casein from milk samples through DEAE anion exchange chromatography was established, and it is suitable for the proteomics research requirements of the beta-casein from human milk.

  18. Characterization of silver ions adsorbed on gold nanorods: surface analysis by using surface-assisted laser desorption/ionization time-of-flight mass spectrometry.

    PubMed

    Niidome, Yasuro; Nakamura, Yuki; Honda, Kanako; Akiyama, Yasuyuki; Nishioka, Koji; Kawasaki, Hideya; Nakashima, Naotoshi

    2009-04-07

    Surface-assisted laser desorption/ionization time-of-flight mass spectrometry (SALDI-MS) indicated AgBr2-, which adsorbed on gold nanorod surfaces, was a key material to control the anisotropic growth of gold nanorods.

  19. Quantitative Organic Acids in Urine by Two Dimensional Gas Chromatography-Time of Flight Mass Spectrometry (GCxGC-TOFMS).

    PubMed

    Sweetman, Lawrence; Ashcraft, Paula; Bennett-Firmin, Jeanna

    2016-01-01

    Seventy-six organic acids in urine specimens are determined with quantitative two dimensional Gas Chromatography-Time of Flight Mass Spectrometry (GCxGC-TOFMS). The specimen is treated with urease to remove urea then derivatized to form pentafluorobenzyl oximes (PFBO) of oxoacids. The sample is then treated with ethyl alcohol to precipitate proteins and centrifuged. After drying the supernatant, the organic acids are derivatized to form volatile trimethylsilyl (TMS) derivatives for separation by capillary two dimensional Gas Chromatography (GCxGC) with temperature programming and modulation. Detection is by Time of Flight Mass Spectrometry (TOFMS) with identification of the organic acids by their mass spectra. Organic acids are quantitated by peak areas of reconstructed ion chromatograms with internal standards and calibration curves. Organic acids are quantified to determine abnormal patterns for the diagnosis of more than 100 inherited disorders of organic acid metabolism. Characteristic abnormal metabolites are quantified to monitor dietary and other modes of treatment for patients who are diagnosed with specific organic acid disorders.

  20. Clustering, methodology, and mechanistic insights into acetate chemical ionization using high-resolution time-of-flight mass spectrometry

    NASA Astrophysics Data System (ADS)

    Brophy, Patrick; Farmer, Delphine K.

    2016-08-01

    We present a comprehensive characterization of cluster control and transmission through the Tofwerk atmospheric pressure interface installed on various chemical ionization time-of-flight mass spectrometers using authentic standards. This characterization of the atmospheric pressure interface allows for a detailed investigation of the acetate chemical ionization mechanisms and the impact of controlling these mechanisms on sensitivity, selectivity, and mass spectral ambiguity with the aim of non-targeted analysis. Chemical ionization with acetate reagent ions is controlled by a distribution of reagent ion-neutral clusters that vary with relative humidity and the concentration of the acetic anhydride precursor. Deprotonated carboxylic acids are primarily detected only if sufficient declustering is employed inside the atmospheric pressure interface. The configuration of a high-resolution time-of-flight chemical ionization mass spectrometer (HR-TOF-CIMS) using an acetate chemical ionization source for non-targeted analysis is discussed. Recent approaches and studies characterizing acetate chemical ionization as it applies to the HR-TOF-CIMS are evaluated in light of the work presented herein.

  1. Decomposition of cyclohexane ion induced by intense femtosecond laser fields by ion-trap time-of-flight mass spectrometry

    SciTech Connect

    Yamazaki, Takao; Watanabe, Yusuke; Kanya, Reika; Yamanouchi, Kaoru

    2016-01-14

    Decomposition of cyclohexane cations induced by intense femtosecond laser fields at the wavelength of 800 nm is investigated by ion-trap time-of-flight mass spectrometry in which cyclohexane cations C{sub 6}H{sub 12}{sup +} stored in an ion trap are irradiated with intense femtosecond laser pulses and the generated fragment ions are recorded by time-of-flight mass spectrometry. The various fragment ion species, C{sub 5}H{sub n}{sup +} (n = 7, 9), C{sub 4}H{sub n}{sup +} (n = 5–8), C{sub 3}H{sub n}{sup +} (n = 3–7), C{sub 2}H{sub n}{sup +} (n = 2–6), and CH{sub 3}{sup +}, identified in the mass spectra show that decomposition of C{sub 6}H{sub 12}{sup +} proceeds efficiently by the photo-irradiation. From the laser intensity dependences of the yields of the fragment ion species, the numbers of photons required for producing the respective fragment ions are estimated.

  2. STiC — a mixed mode silicon photomultiplier readout ASIC for time-of-flight applications

    NASA Astrophysics Data System (ADS)

    Harion, T.; Briggl, K.; Chen, H.; Fischer, P.; Gil, A.; Kiworra, V.; Ritzert, M.; Schultz-Coulon, H.-C.; Shen, W.; Stankova, V.

    2014-02-01

    STiC is an application specific integrated circuit (ASIC) for the readout of silicon photomultipliers. The chip has been designed to provide a very high timing resolution for time-of-flight applications in medical imaging and particle physics. It is dedicated in particular to the EndoToFPET-US project, which is developing an endoscopic PET detector combined with ultrasound imaging for early pancreas and prostate cancer detection. This PET system aims to provide a spatial resolution of 1 mm and a time-of-flight resolution of 200 ps FWHM. The analog frontend of STiC can use either a differential or single ended connection to the SiPM. The time and energy information of the detector signal is encoded into two time stamps. A special linearized time-over-threshold method is used to obtain a linear relation between the signal charge and the measured signal width, improving the energy resolution. The trigger signals are digitized by an integrated TDC module with a resolution of less than 20 ps. The TDC data is stored in an internal memory and transfered over a 160 MBit/s serial link using 8/10 bit encoding. First coincidence measurements using a 3.1 × 3.1 × 15 mm3 LYSO crystal and a S10362-33-50 Hamamtsu MPPC show a coincidence time resolution of less than 285 ps. We present details on the chip design as well as first characterization measurements.

  3. A Rietveld refinement method for angular- and wavelength-dispersive neutron time-of-flight powder diffraction data.

    PubMed

    Jacobs, Philipp; Houben, Andreas; Schweika, Werner; Tchougréeff, Andrei L; Dronskowski, Richard

    2015-12-01

    This paper introduces a two-dimensional extension of the well established Rietveld refinement method for modeling neutron time-of-flight powder diffraction data. The novel approach takes into account the variation of two parameters, diffraction angle 2θ and wavelength λ, to optimally adapt to the varying resolution function in diffraction experiments. By doing so, the refinement against angular- and wavelength-dispersive data gets rid of common data-reduction steps and also avoids the loss of high-resolution information typically introduced by integration. In a case study using a numerically simulated diffraction pattern of Rh0.81Fe3.19N taking into account the layout of the future POWTEX instrument, the profile function as parameterized in 2θ and λ is extracted. As a proof-of-concept, the resulting instrument parameterization is then utilized to perform a typical refinement of the angular- and wavelength-dispersive diffraction pattern of CuNCN, yielding excellent residuals within feasible computational efforts. Another proof-of-concept is carried out by applying the same approach to a real neutron diffraction data set of CuNCN obtained from the POWGEN instrument at the Spallation Neutron Source in Oak Ridge. The paper highlights the general importance of the novel approach for data analysis at neutron time-of-flight diffractometers and its possible inclusion within existing Rietveld software packages.

  4. A Rietveld refinement method for angular- and wavelength-dispersive neutron time-of-flight powder diffraction data

    PubMed Central

    Jacobs, Philipp; Houben, Andreas; Schweika, Werner; Tchougréeff, Andrei L.; Dronskowski, Richard

    2015-01-01

    This paper introduces a two-dimensional extension of the well established Rietveld refinement method for modeling neutron time-of-flight powder diffraction data. The novel approach takes into account the variation of two parameters, diffraction angle 2θ and wavelength λ, to optimally adapt to the varying resolution function in diffraction experiments. By doing so, the refinement against angular- and wavelength-dispersive data gets rid of common data-reduction steps and also avoids the loss of high-resolution information typically introduced by integration. In a case study using a numerically simulated diffraction pattern of Rh0.81Fe3.19N taking into account the layout of the future POWTEX instrument, the profile function as parameterized in 2θ and λ is extracted. As a proof-of-concept, the resulting instrument parameterization is then utilized to perform a typical refinement of the angular- and wavelength-dispersive diffraction pattern of CuNCN, yielding excellent residuals within feasible computational efforts. Another proof-of-concept is carried out by applying the same approach to a real neutron diffraction data set of CuNCN obtained from the POWGEN instrument at the Spallation Neutron Source in Oak Ridge. The paper highlights the general importance of the novel approach for data analysis at neutron time-of-flight diffractometers and its possible inclusion within existing Rietveld software packages. PMID:26664340

  5. Precision Medicine Starts With Preanalytics: Real-Time Assessment of Tissue Fixation Quality by Ultrasound Time-of-Flight Analysis.

    PubMed

    Lerch, Melissa L; Bauer, Daniel R; Chafin, David; Theiss, Abbey; Otter, Michael; Baird, Geoffrey S

    2017-03-01

    Personalized medicine promises diagnosis and treatment of disease at the individual level and relies heavily on clinical specimen integrity and diagnostic assay quality. Preanalytics, the collection and handling steps of a clinical specimen before immunohistochemistry or other clinical assay, are critically important to enable the correct diagnosis of disease. However, the effects of preanalytics are often overlooked due to a lack of standardization and limited assessment tools to quantify their variation. Here, we report a novel real-time ultrasound time-of-flight instrument that is capable of monitoring and imaging the critical step in formalin fixation, diffusion of the fixative into tissue, which provides a quantifiable quality metric for tissue fixation in the clinical laboratory ensuring consistent downstream molecular assay results. We analyzed hundreds of tissue specimens from 34 distinct human tissue types and 12 clinically relevant diseased tissues for diffusion and fixation metrics. Our measurements can be converted into tissue diffusivity constants that correlate with the apparent diffusion constant calculated using magnetic resonance imaging (R=0.83), despite the differences in the approaches, indicating that our approach is biophysically plausible. Using data collected from time-of-flight analysis of many tissues, we have therefore developed a novel rapid fixation program that could ensure high-quality downstream assay results for a broad range of human tissue types.

  6. Time of Flight Measurements of a Plasma Plume in a Glass Tube With and Without a Metal Liner

    NASA Astrophysics Data System (ADS)

    Fiedler Kawaguchi, C.; Schaffner, D. A.; Brown, M. R.; Kaur, M.; Johnson, H. K.

    2016-10-01

    Researchers have yet to attain a self-sustaining fusion reaction in which the amount of energy put in is less than that being produced. A novel approach for the compression and heating of plasma is under development at Swarthmore College with collaboration from Bryn Mawr College through the ARPA-E ALPHA program. Two acceleration modules are being designed to accelerate and compress plasma plumes using pulsed copper rings outside of a glass chamber (module one) and inside of a stainless steel chamber (module two). Measurements of plasma velocity are made using a time of flight technique using Hall probes and magnetic pickup probes (B-dot) probes to measure magnetic field at an array of spatial locations along the chamber. Results shows that the response time of the Hall probe chip used was too slow to register the fast changing fields. B-dot probes were shown to have a fast enough response. Time of flight measurements of field are made in the glass tube using cross correlation methods, with and without a stainless steel liner. Preliminary results show an average increase in the plasma plume velocity, from 38 km/s to 45 km/s, when the glass chamber is lined. Work supported by ARPA-E ALPHA program.

  7. PILGRIM, a Multi-Reflection Time-of-Flight Mass Spectrometer for Spiral2-S3 at GANIL

    NASA Astrophysics Data System (ADS)

    Chauveau, P.; Delahaye, P.; De France, G.; El Abir, S.; Lory, J.; Merrer, Y.; Rosenbusch, M.; Schweikhard, L.; Wolf, R. N.

    2016-06-01

    PILGRIM is a Multi-Reflection Time-of-Flight Mass Spectrometer currently under development at GANIL for the S3 (Super Separator Spectrometer) collaboration and dedicated to the study of the ground-state properties of exotic nuclei. MR-ToF devices have proven to be effective tools for isobar separation (with mass resolving powers in excess of 105) and high-precision mass measurements (relative mass uncertainty down to a few 10-7) within a few tens of milliseconds. These features make them extremely interesting for ensuring beam purity and accurate mass determinations of very exotic, short lived nuclei. PILGRIM is to be set up in the future low energy branch of the S3-Spiral2 project and may also be used as a beam purifier in front of the double Penning trap PIPERADE at DESIR-Spiral2. An electrostatic 90 degree quadrupole deflector to be placed between an RFQ cooler-buncher (for beam preparation) and PILGRIM is also under study. The study on the deflector focuses on conserving the beam features, especially the time-of-flight spread of the ion bunches which has a direct impact on the resolving power of a multi-reflection device.

  8. Precision Medicine Starts With Preanalytics: Real-Time Assessment of Tissue Fixation Quality by Ultrasound Time-of-Flight Analysis

    PubMed Central

    Lerch, Melissa L.; Bauer, Daniel R.; Chafin, David; Theiss, Abbey; Otter, Michael

    2017-01-01

    Personalized medicine promises diagnosis and treatment of disease at the individual level and relies heavily on clinical specimen integrity and diagnostic assay quality. Preanalytics, the collection and handling steps of a clinical specimen before immunohistochemistry or other clinical assay, are critically important to enable the correct diagnosis of disease. However, the effects of preanalytics are often overlooked due to a lack of standardization and limited assessment tools to quantify their variation. Here, we report a novel real-time ultrasound time-of-flight instrument that is capable of monitoring and imaging the critical step in formalin fixation, diffusion of the fixative into tissue, which provides a quantifiable quality metric for tissue fixation in the clinical laboratory ensuring consistent downstream molecular assay results. We analyzed hundreds of tissue specimens from 34 distinct human tissue types and 12 clinically relevant diseased tissues for diffusion and fixation metrics. Our measurements can be converted into tissue diffusivity constants that correlate with the apparent diffusion constant calculated using magnetic resonance imaging (R2=0.83), despite the differences in the approaches, indicating that our approach is biophysically plausible. Using data collected from time-of-flight analysis of many tissues, we have therefore developed a novel rapid fixation program that could ensure high-quality downstream assay results for a broad range of human tissue types. PMID:28027117

  9. LaBr(3):Ce and SiPMs for time-of-flight PET: achieving 100 ps coincidence resolving time.

    PubMed

    Schaart, Dennis R; Seifert, Stefan; Vinke, Ruud; van Dam, Herman T; Dendooven, Peter; Löhner, Herbert; Beekman, Freek J

    2010-04-07

    The use of time-of-flight (TOF) information in positron emission tomography (PET) enables significant improvement in image noise properties and, therefore, lesion detection. Silicon photomultipliers (SiPMs) are solid-state photosensors that have several advantages over photomultiplier tubes (PMTs). SiPMs are small, essentially transparent to 511 keV gamma rays and insensitive to magnetic fields. This enables novel detector designs aimed at e.g. compactness, high resolution, depth-of-interaction (DOI) correction and MRI compatibility. The goal of the present work is to study the timing performance of SiPMs in combination with LaBr(3):Ce(5%), a relatively new scintillator with promising characteristics for TOF-PET. Measurements were performed with two, bare, 3 mm x 3 mm x 5 mm LaBr(3):Ce(5%) crystals, each coupled to a 3 mm x 3 mm SiPM. Using a (22)Na point source placed at various positions in between the two detectors, a coincidence resolving time (CRT) of approximately 100 ps FWHM for 511 keV annihilation photon pairs was achieved, corresponding to a TOF positioning resolution of approximately 15 mm FWHM. At the same time, pulse height spectra with well-resolved full-energy peaks were obtained. To our knowledge this is the best CRT reported for SiPM-based scintillation detectors to date. It is concluded that SiPM-based scintillation detectors can provide timing resolutions at least as good as detectors based on PMTs.

  10. Structural characterization of synthetic poly(ester amide) from sebacic acid and 4-amino-1-butanol by matrix-assisted laser desorption ionization time-of-flight/time-of-flight tandem mass spectrometry.

    PubMed

    Rizzarelli, Paola; Puglisi, Concetto

    2008-01-01

    Matrix-assisted laser desorption/ionization time-of-flight/time-of-flight tandem mass spectrometry (MALDI-TOF/TOF-MS/MS) was employed to analyze a poly(ester amide) sample (PEA-Bu) from the melt condensation of sebacic acid and 4-amino-1-butanol. In particular, we investigated the fragmentation pathways, the ester/amide bond sequences and the structure of species derived from side reactions during the synthesis. MALDI-TOF/TOF-MS/MS analysis was performed on cyclic species and linear oligomers terminated by dicarboxyl groups, carboxyl and hydroxyl groups and diamino alcohol groups. The sodium adducts of these oligomers were selected as precursor ions. Different end groups do not influence the fragmentation of sodiated poly(ester amide) oligomers and similar series of product ions were observed in the MALDI-TOF/TOF-MS/MS spectra. According to the structures of the most abundant product ions identified, the main cleavages proceed through a beta-hydrogen-transfer rearrangement, leading to the selective scission of the --O--CH2-- bonds. Abundant product ions originating from --CH2--CH2-- (beta-gamma) bond cleavage in the sebacate moiety were also detected. Their formation should be promoted by the presence of an alpha,beta-unsaturated ester or amide end group. MALDI-TOF/TOF-MS/MS provided structural information concerning the ester/amide sequences in the polymer chains. In the MALDI-TOF/TOF-MS/MS spectra acquired, using argon as the collision gas, of cyclic species and linear oligomers terminated by diamino alcohol groups, product ions in the low-mass range, undetected in the mass spectra acquired using air as the collision gas, proved to be diagnostic and made it possible to establish the presence of random sequences of ester and amide bonds in the poly(ester amide) sample. Furthermore, MALDI-TOF/TOF-MS/MS provided useful information to clarify the structures of precursor ions derived from side reactions during the synthesis.

  11. A Miniature Laser Desorption/Ionization Time-of-Flight Mass Spectrometer for in Situ Analysis of Mars Surface Composition and Identification of Hazard in Advance of Future Manned Exploration

    NASA Technical Reports Server (NTRS)

    Getty, S. A.; Brinckerhoff, W. B.; Arevalo, R. D.; Floyd, M. M.; Li, X.; Cornish, T.; Ecelberger, S. A.

    2012-01-01

    Future landed missions to Mars will be guided by two strategic directions: (1) sample return to Earth, for comprehensive compositional analyses, as recommended by the 2011 NRC Planetary Decadal Survey; and (2) preparation for human exploration in the 2030s and beyond, as laid out by US space policy. The resultant mission architecture will likely require high-fidelity in situ chemical/organic sample analyses within an extremely constrained resource envelope. Both science goals (e.g., MEPAG Goal 1, return sample selection, etc.) as well as identification of any potential toxic and biological hazards to humans, must be addressed. Over the past several years of instrument development, we have found that the adaptable, compact, and highly capable technique of laser desorption/ionization time-of-flight mass spectrometry (LD-TOF-MS) has significant potential to contribute substantially to these dual objectives. This concept thus addresses Challenge Area 1: instrumentation and Investigation Approaches.

  12. Screening of gluten avenins in foods by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

    PubMed

    Camafeita, E; Méndez, E

    1998-10-01

    The first procedure capable of analysing gluten avenins in gluten-free food samples aimed at the diet control of coeliac patients is described. The method is based on the direct observation of the characteristic avenin mass pattern, around 20-30 kDa, as revealed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI/TOF-MS). The mass range where avenin signals appear is free from mass peaks arising from wheat gliadin, barley hordein and rye secalin protein components, which are also toxic to coeliac patients. Therefore, avenins can easily be screened in complex formula food samples elaborated with mixtures of wheat, barley, rye and oats. In addition, a procedure to quantify avenins in food samples is described on the basis of avenin mass area measurement with a detection limit of 0.4 mg of avenins per 100 g of food.

  13. Research and development on a sub 100 PICO second time-of-flight system based on silicon avalanche diodes

    SciTech Connect

    Choi, Y.; Hirsch, A.; Hauger, A.; Scharenberg, R.; Tincknell, M.; Rai, G.

    1991-12-31

    Particle identification requires a momentum measurement and a second independent determination either energy loss (dE/dx) or time of flight (TOF). To cover a momentum range from 0.1 GeV/c to 1.5 GeV/c in the STAR detector requires both the dE/dx and TOF techniques. This research is designed to develop the avalanche diode (AVD) detectors for TOF systems and evaluate their performance. The test of a small prototype system would be carried out at Purdue and at accelerator test beam sites. The Purdue group has developed a complete test setup for evaluating the time resolution of the AVD`s which includes fast-slow electronic channels, CAMAC based electronic modules and a temperature controlled environment. The AVDs also need to be tested in a 0.5 tesla magnetic field. The Purdue group would augment this test set up to include a magnetic field.

  14. Application of a portable 3He-based polarization insert at a time-of-flight neutron reflectometer

    NASA Astrophysics Data System (ADS)

    Kreuzpaintner, Wolfgang; Masalovich, Sergey; Moulin, Jean-François; Wiedemann, Birgit; Ye, Jingfan; Mayr, Sina; Paul, Amitesh; Haese, Martin; Pomm, Matthias; Böni, Peter

    2017-03-01

    The suitability of a transportable 3He-spin filter as temporary broadband polarizer for a Time-of-Flight neutron reflectometer is demonstrated. A simple two-wavelength method for characterisation of a 3He-spin filter is proposed, which can be applied even if the absolute transmittance of the 3He-spin filter cannot be accurately determined. We demonstrate the data treatment procedure for extracting the spin-up and spin-down neutron reflectivity from measurements obtained with a time dependent 3He polarization. The extraction of a very weak magnetic signal from reflectivity data, measured on the in-situ grown magnetic heterostructure Fe1nm /Cu20nm /Sisubstrate in an externally applied magnetic field of 30 mT is presented and compared to similar measurements on the growth stage Cu20nm /Sisubstrate of the very same sample, which does not yet contain any magnetic material.

  15. Advantages of admittance spectroscopy over time-of-flight technique for studying dispersive charge transport in an organic semiconductor

    NASA Astrophysics Data System (ADS)

    Tsung, K. K.; So, S. K.

    2009-10-01

    We show that admittance spectroscopy (AS) is a better technique than time of flight (TOF) to study the charge transport properties in dispersive materials. The hole transport properties of N ,N'-diphenyl-N ,N'-bis(1-naphthyl)(1,1'-biphenyl)-4,4'-diamine (NPB) doped with different traps were evaluated by AS and TOF techniques. It was found that both techniques can show clear signals for measuring the mobility of NPB doped with shallow traps. When NPB was doped with deep traps, the AS signals were still clear for mobility extraction. In sharp contrast, the TOF transients become featureless and the carrier transit time cannot be determined. The validity of AS in mobility determination was demonstrated by comparing the extracted AS to TOF mobilities. Generally, the hole mobilities extracted by these two techniques were in excellent agreement. In addition, we will demonstrate that AS can be employed to measure carrier dispersion.

  16. Interpretation of time-of-flight distributions for neutral particles under pulsed laser evaporation using direct Monte Carlo simulation

    SciTech Connect

    Morozov, Alexey A.

    2013-12-21

    A theoretical study of the time-of-flight (TOF) distributions under pulsed laser evaporation in vacuum has been performed. A database of TOF distributions has been calculated by the direct simulation Monte Carlo (DSMC) method. It is shown that describing experimental TOF signals through the use of the calculated TOF database combined with a simple analysis of evaporation allows determining the irradiated surface temperature and the rate of evaporation. Analysis of experimental TOF distributions under laser ablation of niobium, copper, and graphite has been performed, with the evaluated surface temperature being well agreed with results of the thermal model calculations. General empirical dependences are proposed, which allow indentifying the regime of the laser induced thermal ablation from the TOF distributions for neutral particles without invoking the DSMC-calculated database.

  17. Extracting grain-orientation-dependent data from in situ time-of-flight neutron diffraction. I. Inverse pole figures

    DOE PAGES

    Stoica, Grigoreta M.; Stoica, Alexandru Dan; An, Ke; ...

    2014-11-28

    The problem of calculating the inverse pole figure (IPF) is analyzed from the perspective of the application of time-of flight neutron diffraction toin situmonitoring of the thermomechanical behavior of engineering materials. On the basis of a quasi-Monte Carlo (QMC) method, a consistent set of grain orientations is generated and used to compute the weighting factors for IPF normalization. The weighting factors are instrument dependent and were calculated for the engineering materials diffractometer VULCAN (Spallation Neutron Source, Oak Ridge National Laboratory). The QMC method is applied to face-centered cubic structures and can be easily extended to other crystallographic symmetries. Examples includemore » 316LN stainless steelin situloaded in tension at room temperature and an Al–2%Mg alloy, substantially deformed by cold rolling and in situannealed up to 653 K.« less

  18. Design of Cherenkov bars for the optical part of the time-of-flight detector in Geant4.

    PubMed

    Nozka, L; Brandt, A; Rijssenbeek, M; Sykora, T; Hoffman, T; Griffiths, J; Steffens, J; Hamal, P; Chytka, L; Hrabovsky, M

    2014-11-17

    We present the results of studies devoted to the development and optimization of the optical part of a high precision time-of-flight (TOF) detector for the Large Hadron Collider (LHC). This work was motivated by a proposal to use such a detector in conjunction with a silicon detector to tag and measure protons from interactions of the type p + p → p + X + p, where the two outgoing protons are scattered in the very forward directions. The fast timing detector uses fused silica (quartz) bars that emit Cherenkov radiation as a relativistic particle passes through and the emitted Cherenkov photons are detected by, for instance, a micro-channel plate multi-anode Photomultiplier Tube (MCP-PMT). Several possible designs are implemented in Geant4 and studied for timing optimization as a function of the arrival time, and the number of Cherenkov photons reaching the photo-sensor.

  19. Direct Chemical Analysis of Solids by Laser Ablation in an Ion-Storage Time-of-Flight Mass Spectrometer

    SciTech Connect

    Klunder, G L; Grant, P M; Andresen, B D; Russo, R E

    2003-09-29

    A laser ablation/ionization mass spectrometer system is described for the direct analysis of solids, particles, and fibers. The system uses a quadrupole ion trap operated in an ion-storage (IS) mode, coupled with a reflectron time-of-flight mass spectrometer (TOF-MS). The sample is inserted radially into the ring electrode and an imaging system allows direct viewing and selected analysis of the sample. Measurements identified trace contaminants of Ag, Sn, and Sb in a Pb target with single laser-shot experiments. Resolution (m/{micro}m) of 1500 and detection limits of approximately 10 pg have been achieved with a single laser pulse. The system configuration and related operating principles for accurately measuring low concentrations of isotopes are described.

  20. Identification of Haemophilus influenzae and Haemophilus haemolyticus by matrix-assisted laser desorption ionization-time of flight mass spectrometry.

    PubMed

    Bruin, J P; Kostrzewa, M; van der Ende, A; Badoux, P; Jansen, R; Boers, S A; Diederen, B M W

    2014-02-01

    Generally accepted laboratory methods that have been used for decades do not reliably distinguish between H. influenzae and H. haemolyticus isolates. H. haemolyticus strains are often incorrectly identified as nontypeable Haemophilus influenzae (NTHi). To distinguish H. influenzae from H. haemolyticus we have created a new database on the matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) bio-typer 2 and compared the results with routine determination of Haemophilus (growth requirement for X and V factor), and multilocus sequence typing (MLST). In total we have tested 277 isolates, 244 H. influenzae and 33 H. haemolyticus. Using MLST as the gold standard, the agreement of MALDI-TOF MS was 99.6 %. MALDI-TOF MS allows reliable and rapid discrimination between H. influenzae and H. haemolyticus.

  1. Characterization of Cryptosporidium parvum by Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry

    PubMed Central

    Magnuson, Matthew L.; Owens, James H.; Kelty, Catherine A.

    2000-01-01

    Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) was used to investigate whole and freeze-thawed Cryptosporidium parvum oocysts. Whole oocysts revealed some mass spectral features. Reproducible patterns of spectral markers and increased sensitivity were obtained after the oocysts were lysed with a freeze-thaw procedure. Spectral-marker patterns for C. parvum were distinguishable from those obtained for Cryptosporidium muris. One spectral marker appears specific for the genus, while others appear specific at the species level. Three different C. parvum lots were investigated, and similar spectral markers were observed in each. Disinfection of the oocysts reduced and/or eliminated the patterns of spectral markers. PMID:11055915

  2. Neutron capture cross section measurement of 151Sm at the CERN neutron time of flight facility (n_TOF).

    PubMed

    Abbondanno, U; Aerts, G; Alvarez-Velarde, F; Alvarez-Pol, H; Andriamonje, S; Andrzejewski, J; Badurek, G; Baumann, P; Becvár, F; Benlliure, J; Berthoumieux, E; Calviño, F; Cano-Ott, D; Capote, R; Cennini, P; Chepel, V; Chiaveri, E; Colonna, N; Cortes, G; Cortina, D; Couture, A; Cox, J; Dababneh, S; Dahlfors, M; David, S; Dolfini, R; Domingo-Pardo, C; Duran, I; Embid-Segura, M; Ferrant, L; Ferrari, A; Ferreira-Marques, R; Frais-Koelbl, H; Furman, W; Goncalves, I; Gallino, R; Gonzalez-Romero, E; Goverdovski, A; Gramegna, F; Griesmayer, E; Gunsing, F; Haas, B; Haight, R; Heil, M; Herrera-Martinez, A; Isaev, S; Jericha, E; Käppeler, F; Kadi, Y; Karadimos, D; Kerveno, M; Ketlerov, V; Koehler, P; Konovalov, V; Krticka, M; Lamboudis, C; Leeb, H; Lindote, A; Lopes, I; Lozano, M; Lukic, S; Marganiec, J; Marrone, S; Martinez-Val, J; Mastinu, P; Mengoni, A; Milazzo, P M; Molina-Coballes, A; Moreau, C; Mosconi, M; Neves, F; Oberhummer, H; O'Brien, S; Pancin, J; Papaevangelou, T; Paradela, C; Pavlik, A; Pavlopoulos, P; Perlado, J M; Perrot, L; Pignatari, M; Plag, R; Plompen, A; Plukis, A; Poch, A; Policarpo, A; Pretel, C; Quesada, J; Raman, S; Rapp, W; Rauscher, T; Reifarth, R; Rosetti, M; Rubbia, C; Rudolf, G; Rullhusen, P; Salgado, J; Soares, J C; Stephan, C; Tagliente, G; Tain, J; Tassan-Got, L; Tavora, L; Terlizzi, R; Vannini, G; Vaz, P; Ventura, A; Villamarin, D; Vincente, M C; Vlachoudis, V; Voss, F; Wendler, H; Wiescher, M; Wisshak, K

    2004-10-15

    The151Sm(n,gamma)152Sm cross section has been measured at the spallation neutron facility n_TOF at CERN in the energy range from 1 eV to 1 MeV. The new facility combines excellent resolution in neutron time-of-flight, low repetition rates, and an unsurpassed instantaneous luminosity, resulting in rather favorable signal/background ratios. The 151Sm cross section is of importance for characterizing neutron capture nucleosynthesis in asymptotic giant branch stars. At a thermal energy of kT=30 keV the Maxwellian averaged cross section of this unstable isotope (t(1/2)=93 yr) was determined to be 3100+/-160 mb, significantly larger than theoretical predictions.

  3. Performance evaluation of time-of-flight and structured light depth sensors in radiometric/geometric variations

    NASA Astrophysics Data System (ADS)

    Shim, Hyunjung; Lee, Seungkyu

    2012-09-01

    Time-of-flight (ToF) and structured light depth cameras capture dense three-dimensional (3-D) geometry that is of great benefit for many computer vision problems. For the past couple of years, depth image based gesture recognition, 3-D reconstruction, and robot localization have received explosive interest in the literature. However, depth measurements present unique systematic errors, specifically when objects have specularity or translucency. We present a quantitative evaluation and analysis of depth errors using both ToF and structured light depth cameras. The evaluation framework used includes a dataset of carefully taken depth images with radiometric/geometric variations of real world objects and their ground truth depth. Our analysis and experiments reveal the different characteristics of the two sensor types and indicate that obtaining high quality depth image from real-world scene still remains a challenging, unsolved problem.

  4. Chemical Analysis of the Chinese Liquor Luzhoulaojiao by Comprehensive Two-Dimensional Gas Chromatography/Time-of-Flight Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Yao, Feng; Yi, Bin; Shen, Caihong; Tao, Fei; Liu, Yumin; Lin, Zhixin; Xu, Ping

    2015-04-01

    Luzhoulaojiao liquor is a type of Chinese liquor that dates back hundreds of years, but whose precise chemical composition remains unknown. This paper describes the screening of the liquor and the identification of its compounds using comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry (GC × GC/TOF-MS). Samples were prepared by both liquid-liquid extraction and solid-phase microextraction, which facilitated the detection of thousands of compounds in the liquor, thus demonstrating the superior performance of the proposed method over those reported in previous studies. A total of 320 compounds were common to all 18 types of Luzhoulaojiao liquor studied here, and 13 abundant and potentially bioactive compounds were further quantified. The results indicated that the high-performance method presented here is well suited for the detection and identification of compounds in liquors. This study also contributes to enriching our knowledge of the contents of Chinese liquors.

  5. Reconstruction of Time-Resolved Neutron Energy Spectra in Z-Pinch Experiments Using Time-of-flight Method

    SciTech Connect

    Rezac, K.; Klir, D.; Kubes, P.; Kravarik, J.

    2009-01-21

    We present the reconstruction of neutron energy spectra from time-of-flight signals. This technique is useful in experiments with the time of neutron production in the range of about tens or hundreds of nanoseconds. The neutron signals were obtained by a common hard X-ray and neutron fast plastic scintillation detectors. The reconstruction is based on the Monte Carlo method which has been improved by simultaneous usage of neutron detectors placed on two opposite sides from the neutron source. Although the reconstruction from detectors placed on two opposite sides is more difficult and a little bit inaccurate (it followed from several presumptions during the inclusion of both sides of detection), there are some advantages. The most important advantage is smaller influence of scattered neutrons on the reconstruction. Finally, we describe the estimation of the error of this reconstruction.

  6. Quantitative analysis of synthetic polymers using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

    PubMed

    Chen, Hui; He, Meiyu; Pei, Jian; He, Haifeng

    2003-12-01

    Quantitative analyses of synthetic polymers were accomplished using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS). Many factors have hindered the development of quantitative measurement of polymers via MALDI TOF MS, e.g., laser power, matrix, cation salt, and cocrystallization. By probing the optimal conditions, two sets of polymers were studied. Fair repeatability of the samples ensures acceptable results. In set 1, two poly(ethylene glycols) with different end groups showed equal desorption/ionization efficiencies. Two synthetic polymers in set 2 with different chemical properties resulted in different MALDI responses. Good linearity was achieved by plotting the relationship between the sample concentration ratio and the total signal intensity ratio in both sets.

  7. Tryptic peptide purification using polyvinylidene difluoride membrane for matrix-assisted laser desorption ionization time of flight mass spectrometry.

    PubMed

    Kurien, Biji T; Scofield, R Hal

    2009-01-01

    Matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI TOF MS) is extremely sensitive to minor impurities in tryptic peptide digests, resulting in suppression of the signal obtained. Therefore, it becomes necessary to purify the sample, especially those samples that fail to yield good mass spectra. Here, we describe a simple protocol using polyvinylidene difluoride (PVDF) membrane for purifying tryptic peptides prior to mass spectrometric analysis. The tryptic digest is spotted on a PVDF membrane, air-dried, and washed. The membrane is then extracted with trifluoroacetic acid/acetonitrile and the extract is then subjected to MALDI TOF MS. Using this procedure, we were able to identify a cross-reactive D1 autoantigen on the surface of neutrophils that bound antibodies targeting Ro 60 autoantigen in systemic lupus erythematosus.

  8. Au@SiO2 core-shell nanoparticles for laser desorption/ionization time of flight mass spectrometry.

    PubMed

    Zhu, Xiaoqing; Wu, Lianglan; Mungra, Divyesh C; Xia, Sijing; Zhu, Jin

    2012-05-21

    In matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS), the analysis capability, especially for small molecules, is often compromised by the addition of organic matrices due to the existence of background signals. Herein we report a new detection method on the utility of core-shell nanoparticles (CSNPs) as energy transfer structure in LDI-TOF-MS. The LDI-TOF-MS based on gold-silica core-shell nanoparticles with ultrathin silica shell of 2-4 nm (Au@utSiO(2) CSNPs) was effectively applied to the analysis of many compounds, especially for small functional molecules and polymers, which was more promising than MALDI-TOF-MS.

  9. Subgap time of flight: A spectroscopic study of deep levels in semi-insulating CdTe:Cl

    NASA Astrophysics Data System (ADS)

    Pousset, J.; Farella, I.; Gambino, S.; Cola, A.

    2016-03-01

    We report on a study of deep levels in semi-insulating CdTe:Cl by means of a time-of-flight spectral approach. By varying the wavelength of a pulsed optical source within the CdTe energy gap, transitions to/from localized levels generate free carriers which are analysed through the induced photocurrent transients. Both acceptor-like centers, related to the A-center, and a midgap level, 0.725 eV from the valence band, have been detected. The midgap level is close to the Fermi level and is possibly a recombination center responsible for the compensation mechanism. When the irradiance is varied, either linear or quadratic dependence of the electron and hole collected charge are observed, depending on the dominant optical transitions. The analysis discloses the potentiality of such a novel approach exploitable in the field of photorefractive materials as well as for deep levels spectroscopy.

  10. Methane ice photochemistry and kinetic study using laser desorption time-of-flight mass spectrometry at 20 K.

    PubMed

    Bossa, J-B; Paardekooper, D M; Isokoski, K; Linnartz, H

    2015-07-14

    The ice photochemistry of pure methane (CH4) is studied at 20 K upon VUV irradiation from a microwave discharge H2 flow lamp. Laser Desorption Post-Ionization Time-Of-Flight Mass Spectrometry (LDPI TOF-MS) is used for the first time to determine branching ratios of primary reactions leading to CH3, CH2, and CH radicals, typically for fluences as expected in space. This study is based on a stable end-products analysis and the mass spectra are interpreted using an appropriate set of coupled reactions and rate constants. This yields clearly different values from previous gas phase studies. The matrix environment as well as the higher efficiency of reverse reactions in the ice clearly favor CH3 radical formation as the main first generation photoproduct.

  11. Concept for a time-of-flight Small Angle Neutron Scattering instrument at the European Spallation Source

    NASA Astrophysics Data System (ADS)

    Jaksch, S.; Martin-Rodriguez, D.; Ostermann, A.; Jestin, J.; Duarte Pinto, S.; Bouwman, W. G.; Uher, J.; Engels, R.; Frielinghaus, H.

    2014-10-01

    A new Small Angle Neutron Scattering instrument is proposed for the European Spallation Source. The pulsed source requires a time-of-flight analysis of the gathered neutrons at the detector. The optimal instrument length is found to be rather large, which allows for a polarizer and a versatile collimation. The polarizer allows for studying magnetic samples and incoherent background subtraction. The wide collimation will host VSANS and SESANS options that increase the resolution of the instrument towards μm and tens of μm, respectively. Two 1 m2 area detectors will cover a large solid angle simultaneously. The expected gains for this new instrument will lie in the range between 20 and 36, depending on the assessment criteria, when compared to up-to-date reactor based instruments. This will open new perspectives for fast kinetics, weakly scattering samples, and multi-dimensional contrast variation studies.

  12. Simulations for a Multi-Reflection Time-of-Flight Mass Spectrometer at the University of Notre Dame

    NASA Astrophysics Data System (ADS)

    Kelly, James M.; Nicoloff, Catherine; Schultz, Bradley E.; Brodeur, Maxime

    2016-09-01

    A multi-reflection time-of-flight mass spectrometer (MR-ToF) has been built at the University of Notre Dame. The MR-ToF will provide isobarically pure ion bunches to experiments at Argonne National Laboratory's (ANL) future ``N = 126 Factory'', a unique facility capable of producing very neutron-rich nuclei around the N = 126 shell closure. Prior to its installation at ANL, the MR-ToF is being evaluated in an off-line test setup consisting of a surface ion source, a Bradbury-Nielsen Gate (BNG) to chop the beam before injection into the MR-ToF, and a micro-channel plate detector to record the resulting bunches. The series of simulations investigating the feasibility of this bunching method, as well as the injection of these bunches into the MR-ToF, will be presented. This work is supported by the National Science Foundation.

  13. Time of flight mass spectrometry of DNA laser-ablated from frozen aqueous solutions: applications to the Human Genome Project

    NASA Astrophysics Data System (ADS)

    Williams, Peter

    1994-02-01

    Time of flight mass spectrometry offers an extremely rapid and accurate alternative to gel electrophoresis for sizing DNA fragments in the Sanger sequencing process, if large single-stranded DNA molecules can be volatilized and ionized without fragmentation. A process based on pulsed laser ablation of thin frozen films of DNA solutions has been shown to ablate intact DNA molecules up to [approximate]400 kDa in mass, and also has been shown to yield molecular ions of single-stranded DNA up to [approximate]18 500 Da. The theoretical basis and the progress to date in this approach are described and the potential impact of mass spectrometry on large-scale DNA sequencing is discussed.

  14. Analysis of chlorophylls and their derivatives by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry.

    PubMed

    Suzuki, Toshiyuki; Midonoya, Hitoshi; Shioi, Yuzo

    2009-07-01

    The analysis of chlorophylls and their derivatives by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry is described. Four matrices-sinapinic acid, a-cyano-4-hydroxycinnnamic acid, terthiophene, and 3-aminoquinoline-were examined to determine optimal conditions for analysis of the molecular mass and structure of chlorophyll a as a representative chlorophyll. Among them, terthiophene was the most efficient without releasing metal ions, although it caused fragmentation of the phytol-ester linkage. Terthiophene was useful for the analyses of chlorophyll derivatives as well as porphyrin products such as 8-deethyl-8-vinyl-chlorophyll a, pheophorbide a, pyropheophorbide a, bacteriochlorophyll a esterified phytol, and protoporphyrin IX. The current method is suitable for rapid and accurate determination of the molecular mass and structure of chlorophylls and porphyrins.

  15. Quantitative time-of-flight secondary ion mass spectrometry for the characterization of multicomponent adsorbed protein films

    NASA Astrophysics Data System (ADS)

    Wagner, M. S.; Shen, M.; Horbett, T. A.; Castner, David G.

    2003-01-01

    Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is ideal for the characterization of adsorbed proteins due to its chemical specificity and surface sensitivity. We have employed ToF-SIMS and multivariate analysis to determine the surface composition of adsorbed protein films from binary mixtures, blood serum, and blood plasma. Good correlation between ToF-SIMS data and independent radiolabeling studies was achieved for binary mixtures, though these results depended on the substrate. Qualitative insight into the composition of the serum and plasma protein films was obtained via comparison to standard single protein film spectra. ToF-SIMS and multivariate analysis were able to measure the surface composition of multicomponent adsorbed protein films.

  16. Top-down proteomics with a quadrupole time-of-flight mass spectrometer and collision-induced dissociation.

    PubMed

    Armirotti, Andrea; Benatti, Umberto; Damonte, Gianluca

    2009-03-01

    With slight modifications of the instrumental parameters, we demonstrate that satisfactory top-down data can be obtained with collision-induced dissociation (CID) tandem mass spectrometry on a quadrupole time-of-flight (qTOF) instrument not originally designed for this purpose. Protein identification is achieved with both N- and C-terminal sequence tags and BLAST database searches. The accurate mass measurement of multiply charged fragment ions (mostly y and b-type) supplements the limited set of cleavage sites and provides a high degree of sequence coverage (90-100%). Post-translational modification issues can be addressed too. This approach might help those mass spectrometry (MS) core facilities that are not able to afford very high-resolution instruments, thus expanding the benefits of top-down protein analysis over the worldwide MS community.

  17. Determination and imaging of metabolites from Vitis vinifera leaves by laser desorption/ionisation time-of-flight mass spectrometry.

    PubMed

    Hamm, Gregory; Carré, Vincent; Poutaraud, Anne; Maunit, Benoît; Frache, Gilles; Merdinoglu, Didier; Muller, Jean-François

    2010-02-01

    Analysis of grapevine phytoalexins at the surface of Vitis vinifera leaves has been achieved by laser desorption/ionisation time-of-flight mass spectrometry (LDI-ToFMS) without matrix deposition. This simple and rapid sampling method was successfully applied to map small organic compounds at the surface of grapevine leaves. It was also demonstrated that the laser wavelength is a highly critical parameter. Both 266 and 337 nm laser wavelengths were used but the 266 nm wavelength gave increased spatial resolution and better sensitivity for the detection of the targeted metabolites (resveratrol and linked stilbene compounds). Mass spectrometry imaging of grapevine Cabernet Sauvignon leaves revealed specific locations with respect to Plasmopara viticola pathogen infection or light illumination.

  18. Structure of Lipid A from Pseudomonas corrugata by electrospray ionization quadrupole time-of-flight tandem mass spectrometry.

    PubMed

    Corsaro, M M; Piaz, F Dal; Lanzetta, R; Naldi, T; Parrilli, M

    2004-01-01

    The use of the electrospray ionization quadrupole time-of-flight tandem mass spectrometry (ESI-QTOFMS) technique for the structural determination of Lipid A from Pseudomonas corrugata is described. This technique appears to be more sensitive with respect to other commonly used tandem mass spectrometric approaches, and was very valuable in the structural determination of the highly heterogeneous Lipid A fractions. The Lipid A fraction consists mainly of a pentaacyl component in which 3-hydroxydecanoyl [10:0(3-OH)] and 3-hydroxydodecanoyl [12:0(3-OH)] are linked as primary acyl substituents to the classical bisphosphorylated beta-(1' --> 6)-linked D-glucosamine disaccharide. Secondary substitution of N-acyl fatty acids with dodecanoyl residues [12:0] and/or its 2-OH derivatives was also observed.

  19. Time-of-flight secondary ion mass spectrometry with transmission of energetic primary cluster ions through foil targets

    SciTech Connect

    Hirata, K.; Saitoh, Y.; Chiba, A.; Yamada, K.; Matoba, S.; Narumi, K.

    2014-03-15

    We developed time-of-flight (TOF) secondary ion (SI) mass spectrometry that provides informative SI ion mass spectra without needing a sophisticated ion beam pulsing system. In the newly developed spectrometry, energetic large cluster ions with energies of the order of sub MeV or greater are used as primary ions. Because their impacts on the target surface produce high yields of SIs, the resulting SI mass spectra are informative. In addition, the start signals necessary for timing information on primary ion incidence are provided by the detection signals of particles emitted from the rear surface of foil targets upon transmission of the primary ions. This configuration allows us to obtain positive and negative TOF SI mass spectra without pulsing system, which requires precise control of the primary ions to give the spectra with good mass resolution. We also successfully applied the TOF SI mass spectrometry with energetic cluster ion impacts to the chemical structure characterization of organic thin film targets.

  20. Mechanical Modulation of Phonon-Assisted Field Emission in a Silicon Nanomembrane Detector for Time-of-Flight Mass Spectrometry

    PubMed Central

    Park, Jonghoo; Blick, Robert H.

    2016-01-01

    We demonstrate mechanical modulation of phonon-assisted field emission in a free-standing silicon nanomembrane detector for time-of-flight mass spectrometry of proteins. The impacts of ion bombardment on the silicon nanomembrane have been explored in both mechanical and electrical points of view. Locally elevated lattice temperature in the silicon nanomembrane, resulting from the transduction of ion kinetic energy into thermal energy through the ion bombardment, induces not only phonon-assisted field emission but also a mechanical vibration in the silicon nanomembrane. The coupling of these mechanical and electrical phenomenon leads to mechanical modulation of phonon-assisted field emission. The thermal energy relaxation through mechanical vibration in addition to the lateral heat conduction and field emission in the silicon nanomembrane offers effective cooling of the nanomembrane, thereby allowing high resolution mass analysis. PMID:26861329

  1. Chemical Analysis of the Chinese Liquor Luzhoulaojiao by Comprehensive Two-Dimensional Gas Chromatography/Time-of-Flight Mass Spectrometry

    PubMed Central

    Yao, Feng; Yi, Bin; Shen, Caihong; Tao, Fei; Liu, Yumin; Lin, Zhixin; Xu, Ping

    2015-01-01

    Luzhoulaojiao liquor is a type of Chinese liquor that dates back hundreds of years, but whose precise chemical composition remains unknown. This paper describes the screening of the liquor and the identification of its compounds using comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry (GC × GC/TOF-MS). Samples were prepared by both liquid-liquid extraction and solid-phase microextraction, which facilitated the detection of thousands of compounds in the liquor, thus demonstrating the superior performance of the proposed method over those reported in previous studies. A total of 320 compounds were common to all 18 types of Luzhoulaojiao liquor studied here, and 13 abundant and potentially bioactive compounds were further quantified. The results indicated that the high-performance method presented here is well suited for the detection and identification of compounds in liquors. This study also contributes to enriching our knowledge of the contents of Chinese liquors. PMID:25857434

  2. Second generation fusion neutron time-of-flight spectrometer at optimized rate for fully digital data acquisition

    SciTech Connect

    Zhang, X. E-mail: jnke1@icloud.com Fan, T.; Yuan, X.; Xie, X.; Chen, Z.; Källne, J.; Gorini, G.; Nocente, M.

    2014-04-15

    The progress on high-rate event recording of data is taken as starting point to revisit the design of fusion neutron spectrometers based on the TOF (time-of-flight) technique. The study performed was aimed at how such instruments for optimized rate (TOFOR) can be further developed to enhance the plasma diagnostic capabilities based on measurement of the 2.5 MeV dd neutron emission from D plasmas, especially the weak spectral components that depend on discrimination of extraneous events. This paper describes a design (TOFOR II) adapted for use with digital wave form recording of all detector pulses providing information on both amplitude (pulse height) and timing. The results of simulations are presented and the performance enhancement is assessed in comparison to the present.

  3. A direct determination of a glucose-arsenic complex by electrospray ionization time of flight mass spectrometry.

    PubMed

    Mandal, Santi M

    2011-10-01

    Electrospray ionization time of flight mass spectrometry (ESI-TOF-MS) was used to identify elemental ions from the glucose-arsenic interaction in the aqueous phase. In glucose solution, the most abundant ions were m/z 203, m/z 163, m/z 158, m/z 145 and m/z 115, whereas some additional arsenic bearing ions, m/z 271, m/z 235 and m/z 213 were observed from a glucose-arsenic solution in alkaline pH (≥ 7.5) at 37 °C. The binding was best fitted to 1:1 isotherm model and the value of the dissociation constant (K(d)) was 39.8 μM. Results suggest that the polyatomic ions derived from glucose interact with the available arsenic ions in blood and form a complex which might play a role in diseases caused by arsenic exposure.

  4. Time of flight and the MUSE experiment in the PIM1 Channel at the Paul Sherrer Institute

    NASA Astrophysics Data System (ADS)

    Lin, Wan; MUSE Collaboration

    2015-10-01

    The MUSE experiment in the PIM1 Channel at the Paul Sherrer Institute in Villigen, Switzerland, measures scattering of electrons and muons from a liquid hydrogen target. The intent of the experiment is to deduce from the scattering probabilities whether the radius of the proton is the same when determined from the scattering of the two different particle types. An important technique for the experiment is precise timing measurements, using high precision scintillators and a beam Cerenkov counter. We will describe the motivations for the precise timing measurement. We will present results for the timing measurements from prototype experimental detectors. We will also present results from a simulation program, Geant4, that was used to calculate energy loss corrections to the time of flight determined between the beam Cherenkov counter and the scintillator. This work is supported in part by the U.S. National Science Foundation Grant PHY 1306126 and the Douglass Project for Women in Math, Science, and Engineering.

  5. Current status of a time-of-flight single crystal neutron diffractometer SENJU at J-PARC

    NASA Astrophysics Data System (ADS)

    Tamura, I.; Oikawa, K.; Kawasaki, T.; Ohhara, T.; Kaneko, K.; Kiyanagi, R.; Kimura, H.; Takahashi, M.; Kiyotani, T.; Arai, M.; Noda, Y.; Ohshima, K.

    2012-02-01

    SENJU is a state-of-the-art single crystal time-of-flight Laue diffractometer in Materials and Life Science Experimental Facility at Japan Proton Accelerator Research Complex (J-PARC). The diffractometer is designed for precise crystal and magnetic structure analyses under multiple extreme conditions, such as low temperature, high-pressure, high-magnetic field. Measurements using small sample less than 1.0 mm3 will be also realized, which allows us to study wide variety of materials. SENJU is using a poisoned decoupled moderator to obtain peak profiles of Bragg reflection, and intensity distributions of superlattice reflections and diffuse scatterings with good accuracy. At the beginning, the diffractometer will have 31 two-dimensional scintillator detectors to cover wide area of reciprocal lattice space by a single measurement. The instrument is currently under construction and is scheduled to start on-beam commissioning in February 2012.

  6. Potato glycoalkaloids in soil-optimising liquid chromatography-time-of-flight mass spectrometry for quantitative studies.

    PubMed

    Jensen, Pia H; Juhler, René K; Nielsen, Nikoline J; Hansen, Thomas H; Strobel, Bjarne W; Jacobsen, Ole S; Nielsen, John; Hansen, Hans Christian B

    2008-02-22

    Potato glycoalkaloids are produced in high amounts in potato fields during the growth season and losses to soil potentially impact shallow groundwater and via tiles to fresh water ecosystems. A quantitative liquid chromatography-electrospray ionization time-of-flight mass spectrometry (LC-ESI-TOF-MS) method for determination and quantification of potato glycoalkaloids and their metabolites in aqueous soil extracts was developed. The LC-ESI-TOF-MS method had linearities up to 2000microg/L for alpha-solanine and alpha-chaconine and up to 760microg/L for solanidine. No matrix effect was observed, and the detection limits found were in the range 2.2-4.7microg/L. The method enabled quantification of the potato glycoalkaloids in environmental samples.

  7. Analysis and Quantitation of Glycated Hemoglobin by Matrix Assisted Laser Desorption/Ionization Time of Flight Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Hattan, Stephen J.; Parker, Kenneth C.; Vestal, Marvin L.; Yang, Jane Y.; Herold, David A.; Duncan, Mark W.

    2016-03-01

    Measurement of glycated hemoglobin is widely used for the diagnosis and monitoring of diabetes mellitus. Matrix assisted laser desorption/ionization (MALDI) time of flight (TOF) mass spectrometry (MS) analysis of patient samples is used to demonstrate a method for quantitation of total glycation on the β-subunit of hemoglobin. The approach is accurate and calibrated with commercially available reference materials. Measurements were linear (R2 > 0.99) across the clinically relevant range of 4% to 20% glycation with coefficients of variation of ≤ 2.5%. Additional and independent measurements of glycation of the α-subunit of hemoglobin are used to validate β-subunit glycation measurements and distinguish hemoglobin variants. Results obtained by MALDI-TOF MS were compared with those obtained in a clinical laboratory using validated HPLC methodology. MALDI-TOF MS sample preparation was minimal and analysis times were rapid making the method an attractive alternative to methodologies currently in practice.

  8. Time-of-flight analysis of charge mobility in a Cu-phthalocyanine-based discotic liquid crystal semiconductor

    NASA Astrophysics Data System (ADS)

    Fujikake, Hideo; Murashige, Takeshi; Sugibayashi, Makiko; Ohta, Kazuchika

    2004-10-01

    We used a time-of-flight method to study the charge carrier mobility properties of a molecular-aligned discotic liquid crystal semiconductor based on Cu-phthalocyanine. The heated isotropic-phase semiconductor material was sandwiched between transparent electrodes coated onto glass substrates without conventional alignment layers. This was then cooled, and a discotic liquid crystal semiconductor cell was obtained, which we used to make mobility measurements. The material had a fixed molecular alignment due to the supercooling of the hexagonal columnar mesophase. It was clarified that the carrier mobility for electrons was as high as it was for holes at room temperature. The maximum value of negative charge mobility reached 2.60×10-3cm2/Vs, although negative carrier mobility is often much lower than positive carrier mobility in other organic semiconductors, including conventional Cu-phthalocyanine vacuum-deposited films.

  9. Application of time of flight secondary ion mass spectrometry to the in situ analysis of ballpoint pen inks on paper.

    PubMed

    Coumbaros, John; Kirkbride, K Paul; Klass, Gunter; Skinner, William

    2009-12-15

    Results presented in this paper demonstrate that time of flight secondary ion mass spectrometry (TOF-SIMS) can be used for the analysis of ballpoint pen inks producing mass spectra that were highly characteristic of the constituent dyes and inorganic substances used in their formulations. Analysis was performed directly off the substrate (typically document paper) containing the ink with no interference from the background matrix. The resultant spectra were highly characteristic of the ink formulation and could be used to confidently discriminate between different inks. No extraction or complicated sample preparation was necessary which ensures the integrity of the document under examination. This is not only important in forensic applications but also indicates the potential for the application of this technique to the analysis of inks on documents of historical or archaeological significance. TOF-SIMS was also shown to be capable of analysing ink containing a mixture of dyes, initially separated by thin-layer chromatography, directly on the chromatographic material.

  10. Time of Flight Measurements for Neutrons Produced in Reactions Driven by Laser-Target Interactions at Petawatt level

    NASA Astrophysics Data System (ADS)

    Kisyov, S.; Negoita, F.; Gugiu, M. M.; Higginson, D. P.; Vassura, L.; Borghesi, M.; Bernstein, L.; Bleuel, D. L.; Gobet, F.; Goldblum, B. L.; Green, A.; Hannachi, F.; Kar, S.; Petrascu, H.; Pietreanu, D.; Quentin, L.; Schroer, A.-M.; Tarisien, M.; Versteegen, M.; Willi, O.; Antici, P.; Fuchs, J.

    Short intense pulses of fast neutrons were produced in a two stage laser-driven experiment. Protons were accelerated by means of the Target Normal Sheath Acceleration (TNSA) method using the TITAN facility at the Lawrence Livermore National Laboratory. Neutrons were obtained following interactions of the protons with a secondary lithium fluoride (LiF) target. The properties of the neutron flux were studied using BC-400 plastic scintillation detectors and the neutron time of flight (nTOF) technique. The detector setup and the experimental conditions were simulated with the Geant4 toolkit. The effects of different components of the experimental setup on the nTOF were studied. Preliminary results from a comparison between experimental and simulated nTOF distributions are presented.

  11. Fusion neutron detector for time-of-flight measurements in z-pinch and plasma focus experiments

    SciTech Connect

    Klir, D.; Kravarik, J.; Kubes, P.; Rezac, K.; Litseva, E.; Tomaszewski, K.; Karpinski, L.; Paduch, M.; Scholz, M.

    2011-03-15

    We have developed and tested sensitive neutron detectors for neutron time-of-flight measurements in z-pinch and plasma focus experiments with neutron emission times in tens of nanoseconds and with neutron yields between 10{sup 6} and 10{sup 12} per one shot. The neutron detectors are composed of a BC-408 fast plastic scintillator and Hamamatsu H1949-51 photomultiplier tube (PMT). During the calibration procedure, a PMT delay was determined for various operating voltages. The temporal resolution of the neutron detector was measured for the most commonly used PMT voltage of 1.4 kV. At the PF-1000 plasma focus, a novel method of the acquisition of a pulse height distribution has been used. This pulse height analysis enabled to determine the single neutron sensitivity for various neutron energies and to calibrate the neutron detector for absolute neutron yields at about 2.45 MeV.

  12. Investigation of protein-protein noncovalent interactions in soybean agglutinin by electrospray ionization time-of-flight mass spectrometry.

    PubMed

    Tang, X J; Brewer, C F; Saha, S; Chernushevich, I; Ens, W; Standing, K G

    1994-09-01

    Noncovalent interactions in soybean agglutinin (SBA) were studied on an electrospray ionization (ESI) time-of-flight mass spectrometer constructed recently at the University of Manitoba. The high m/z range and high sensitivity of the instrument together with mild ESI interface conditions turned out to be ideal for detecting this noncovalently bonded tetrameric protein (MW approximately 116,000 Da) in low charge states (z = 23 to 27). By altering the acetonitrile content of the SBA solutions it was shown that the observed SBA tetramers are due to structurally specific noncovalent associations in solution. Octamers and dodecamers (MW approximately 350,000 Da) were also detected. Information on the quaternary structure of the tetramers was obtained by analyzing the fragment-ion spectrum resulting from the collision-induced dissociation of the tetramer ions.

  13. Quantitative profiling of phospholipids by multiple precursor ion scanning on a hybrid quadrupole time-of-flight mass spectrometer.

    PubMed

    Ekroos, Kim; Chernushevich, Igor V; Simons, Kai; Shevchenko, Andrej

    2002-03-01

    A hybrid quadrupole time-of-flight mass spectrometer featured with ion trapping capabilities was employed for quantitative profiling of total extracts of endogenous phospholipids. Simultaneous acquisition of precursor ion spectra of multiple fragment ions allowed detection of major classes of phospholipids in a single experiment. Relative changes in their concentration were monitored using a mixture of isotopically labeled endogenous lipids as a comprehensive internal standard. Precursor ion scanning spectra were acquired simultaneously for acyl anions of major fatty acids in negative ion mode and identified the fatty acid moieties and their relative position at the glycerol backbone in individual lipid species. Taken together, a combination of multiple precursor ion scans allowed quantitative monitoring of major perturbation in phospholipid composition and elucidating of molecular heterogeneity of individual lipid species.

  14. Investigating ion-surface collisions with a niobium superconducting tunnel junction detector in a time-of-flight mass spectrometer

    SciTech Connect

    Westmacott, G.; Zhong, F.; Frank, M.; Friedrich, S.; Labov, S.; Benner, W.H.

    1999-12-01

    The performance of an energy sensitive, niobium superconducting tunnel junction detector is investigated by measuring the pulse height produced by impacting molecular and atomic ions at different kinetic energies. Ions are produced by laser resorption and matrix-assisted laser desorption in a time-of-flight mass spectrometer. Results show that the STJ detector pulse height decreases for increasing molecular ion mass, passes through a minimum at around 2000 Da, and the increases with increasing mass of molecular ions above 2000Da. The detector does not show a decline in sensitivity for high mass ions as is observed with microchannel plate ion detectors. These detector plus height measurements are discussed in terms of several physical mechanisms involved in an ion-surface collision.

  15. Microscopic observation of carrier-transport dynamics in quantum-structure solar cells using a time-of-flight technique

    SciTech Connect

    Toprasertpong, Kasidit; Fujii, Hiromasa; Sugiyama, Masakazu; Nakano, Yoshiaki; Kasamatsu, Naofumi; Kada, Tomoyuki; Asahi, Shigeo; Kita, Takashi; Wang, Yunpeng; Watanabe, Kentaroh

    2015-07-27

    In this study, we propose a carrier time-of-flight technique to evaluate the carrier transport time across a quantum structure in an active region of solar cells. By observing the time-resolved photoluminescence signal with a quantum-well probe inserted under the quantum structure at forward bias, the carrier transport time can be efficiently determined at room temperature. The averaged drift velocity shows linear dependence on the internal field, allowing us to estimate the quantum structure as a quasi-bulk material with low effective mobility containing the information of carrier dynamics. We show that this direct and real-time observation is more sensitive to carrier transport than other conventional techniques, providing better insights into microscopic carrier transport dynamics to overcome a device design difficulty.

  16. Rapid assignment of malting barley varieties by matrix-assisted laser desorption-ionisation - Time-of-flight mass spectrometry.

    PubMed

    Šedo, Ondrej; Kořán, Michal; Jakešová, Michaela; Mikulíková, Renata; Boháč, Michal; Zdráhal, Zbyněk

    2016-09-01

    A method for discriminating malting barley varieties based on direct matrix-assisted laser desorption-ionisation - time-of-flight mass spectrometry (MALDI-TOF MS) fingerprinting of proteins was developed. Signals corresponding to hordeins were obtained by simple mixing of powdered barley grain with a MALDI matrix solution containing 12.5mgmL(-1) of ferulic acid in an acetonitrile:water:formic acid 50:33:17 v/v/v mixture. Compared to previous attempts at MALDI-TOF mass spectrometric analysis of barley proteins, the extraction and fractionation steps were practically omitted, resulting in a significant reduction in analytical time and costs. The discriminatory power was examined on twenty malting barley varieties and the practicability of the method was tested on sixty barley samples acquired from Pilsner Urquell Brewery. The method is proposed as a rapid tool for variety assignment and purity determination of malting barley that may replace gel electrophoresis currently used for this purpose.

  17. Discrimination of Penicillium isolates by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry fingerprinting.

    PubMed

    Hettick, Justin M; Green, Brett J; Buskirk, Amanda D; Kashon, Michael L; Slaven, James E; Janotka, Erika; Blachere, Francoise M; Schmechel, Detlef; Beezhold, Donald H

    2008-08-01

    Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was used to generate highly reproducible mass spectral 'fingerprints' for twelve Penicillium species. Prior to MALDI-TOF MS analysis, eight replicate cultures of each Penicillium species were subjected to three one-minute bead-beating cycles in an acetonitrile/trifluoroacetic acid solvent. The mass spectra contained abundant peaks in the range of m/z 5000-20 000, and allowed unambiguous discrimination between species. In addition, a biomarker common to all Penicillium mass spectra was observed at m/z 13 900. Discriminant analysis using the MALDI-TOF MS data yielded classification error rates of 0% (i.e. 100% correct identification), indicating that MALDI-TOF MS data may be a useful diagnostic tool for the objective identification of Penicillium species of environmental and clinical importance.

  18. Tuning the instrument resolution using chopper and time of flight at the small-angle neutron scattering diffractometer KWS-2

    PubMed Central

    Radulescu, Aurel; Székely, Noémi Kinga; Polachowski, Stephan; Leyendecker, Marko; Amann, Matthias; Buitenhuis, Johan; Drochner, Matthias; Engels, Ralf; Hanslik, Romuald; Kemmerling, Günter; Lindner, Peter; Papagiannopoulos, Aristeidis; Pipich, Vitaliy; Willner, Lutz; Frielinghaus, Henrich; Richter, Dieter

    2015-01-01

    Following demand from the user community regarding the possibility of improving the experimental resolution, the dedicated high-intensity/extended Q-range SANS diffractometer KWS-2 of the Jülich Centre for Neutron Science at the Heinz Maier-Leibnitz Center in Garching was equipped with a double-disc chopper with a variable opening slit window and time-of-flight (TOF) data acquisition option. The chopper used in concert with a dedicated high-intensity velocity selector enables the tuning at will of the wavelength resolution Δλ/λ within a broad range, from 20% (standard) down to 2%, in a convenient and safe manner following pre-planned or spontaneous decisions during the experiment. The new working mode is described in detail, and its efficiency is demonstrated on several standard samples with known properties and on a completely new crystallizable copolymer system, which were investigated using both the conventional (static) and TOF modes. PMID:26664343

  19. Letter: A method for the chromatic aberration correction of a laser time of-flight mass analyzer.

    PubMed

    Sysoeva, Elizaveta A; Sysoev, Alexander A

    2016-01-01

    The new ion-optical system of the laser time-of-flight (TOF) mass spectrometer on the basis of two tandem wedge-shape reflectors has been offered and implemented. A new method of correcting chromatic aberration by the ion energy was proposed that used a wire electrode unit with adjustable potentials. This unit allows one to adjust the local TOF of the ions in a narrow energy range ± (1-2)% within the total ion packet with an energy spread of ± 20%. The method reduces the duration of the ion packets by up to 1.5ns, which enables us to obtain the restriction of resolution at a level not worse than R ~ 10500 for a TOF ~35 µs. The aim of the project is to increase the separation of isobaric ions to improve the limit of detection of the laser TOF-MS for the analysis of high-purity samples.

  20. Sensitivity and fragmentation calibration of the time-of-flight mass spectrometer RTOF on board ESA's Rosetta mission

    NASA Astrophysics Data System (ADS)

    Gasc, Sébastien; Altwegg, Kathrin; Fiethe, Björn; Jäckel, Annette; Korth, Axel; Le Roy, Léna; Mall, Urs; Rème, Henri; Rubin, Martin; Hunter Waite, J.; Wurz, Peter

    2017-01-01

    The European Space Agency's Rosetta spacecraft, with the Rosetta Orbiter Spectrometer for Ion and Neutral Analysis (ROSINA) onboard, has been following and observing comet 67P/Churyumov-Gerasimenko since summer 2014. Prior to this period, and due to a technical failure also during this period, optimization and calibration campaigns have been conducted on ground with the Reflectron-type Time Of Flight (RTOF) mass spectrometer as a preparatory work for the analysis of data recorded during the science phase of the mission. In this work, we show the evolution of the performance of RTOF, and demonstrate and quantify the sensitivity and functionality of RTOF onboard Rosetta. We also present a fragmentation and sensitivity database for the most abundant molecules observed around the comet such as H2O, CO, CO2, as well as the noble gases.