  1. Gas chromatographic instrumentation for the analysis of aerosols and gases in Titan's atmosphere

    NASA Technical Reports Server (NTRS)

    Scattergood, T. W.; Valentin, J. R.; Ohara, B. J.; Kojiro, D. R.; Carle, G. C.

    1987-01-01

    Instrumentation presently being developed by NASA for the collection and analysis of organic gases and aerosols in Titan's atmosphere is described together with the results of the preliminary experiments. For the aerosols, stepwise pyrolysis was shown to be a suitable method for preparing complex organic material for gas chromatography (GC), and a pyrolysis-gas chromatograph was developed and successfully used to analyze a simulated Titan aerosol. Atmospheric gases will be collected by a low-pressure gas sampling system using large-volume sample loops and analyzed by GC. The results of preliminary studies using a 20 cu cm sampling system and a very sensitive metastable ionization detector showed that hydrocarbon components at the 10 ppb level can be detected. Studies are in progress on shortening the overall analysis time by improving the pyrolysis system, the gas sampling system, and the associated gas chromatograph. Further development of the gas sampling system is planned to ensure rapid collection of samples adequate for analysis by GC over the entire range of pressures to be encountered during the probe's descent.

  2. On-line gas chromatographic analysis of airborne particles

    DOEpatents

    Hering, Susanne V.; Goldstein, Allen H.

    2012-01-03

    A method and apparatus for the in-situ, chemical analysis of an aerosol. The method may include the steps of: collecting an aerosol; thermally desorbing the aerosol into a carrier gas to provide desorbed aerosol material; transporting the desorbed aerosol material onto the head of a gas chromatography column; analyzing the aerosol material using a gas chromatograph, and quantizing the aerosol material as it evolves from the gas chromatography column. The apparatus includes a collection and thermal desorption cell, a gas chromatograph including a gas chromatography column, heated transport lines coupling the cell and the column; and a quantization detector for aerosol material evolving from the gas chromatography column.

  3. Microminiature gas chromatograph

    DOEpatents

    Yu, Conrad M.

    1996-01-01

    A microminiature gas chromatograph (.mu.GC) comprising a least one silicon wafer, a gas injector, a column, and a detector. The gas injector has a normally closed valve for introducing a mobile phase including a sample gas in a carrier gas. The valve is fully disposed in the silicon wafer(s). The column is a microcapillary in silicon crystal with a stationary phase and is mechanically connected to receive the mobile phase from the gas injector for the molecular separation of compounds in the sample gas. The detector is mechanically connected to the column for the analysis of the separated compounds of sample gas with electronic means, e.g., ion cell, field emitter and PIN diode.

  4. Microminiature gas chromatograph

    DOEpatents

    Yu, C.M.

    1996-12-10

    A microminiature gas chromatograph ({mu}GC) comprising a least one silicon wafer, a gas injector, a column, and a detector. The gas injector has a normally closed valve for introducing a mobile phase including a sample gas in a carrier gas. The valve is fully disposed in the silicon wafer(s). The column is a microcapillary in silicon crystal with a stationary phase and is mechanically connected to receive the mobile phase from the gas injector for the molecular separation of compounds in the sample gas. The detector is mechanically connected to the column for the analysis of the separated compounds of sample gas with electronic means, e.g., ion cell, field emitter and PIN diode. 7 figs.

  5. Microminiature gas chromatographic column

    NASA Technical Reports Server (NTRS)

    Donaldson, R. W., Jr.

    1972-01-01

    Techniques commonly used for fabrication of integrated circuits are utilized to produce long capillary tubes for microminiature chromatographs. Method involves bonding of flat silicon plate to top of spirally grooved silicon chip to close groove and form capillary column.

  6. Dual liquid and gas chromatograph system

    DOEpatents

    Gay, Don D.

    1985-01-01

    A chromatographic system that utilizes one detection system for gas chromatographic and micro-liquid chromatographic determinations. The detection system is a direct-current, atmospheric-pressure, helium plasma emission spectrometer. The detector utilizes a non-transparent plasma source unit which contains the plasma region and two side-arms which receive effluents from the micro-liquid chromatograph and the gas chromatograph. The dual nature of this chromatographic system offers: (1) extreme flexibility in the samples to be examined; (2) extremely low sensitivity; (3) element selectivity; (4) long-term stability; (5) direct correlation of data from the liquid and gas samples; (6) simpler operation than with individual liquid and gas chromatographs, each with different detection systems; and (7) cheaper than a commercial liquid chromatograph and a gas chromatograph.

  7. Dual liquid and gas chromatograph system

    DOEpatents

    Gay, D.D.

    A chromatographic system is described that utilizes one detection system for gas chromatographic and micro-liquid chromatographic determinations. The detection system is a direct-current, atmospheric-pressure, helium plasma emission spectrometer. The detector utilizes a nontransparent plasma source unit which contains the plasma region and two side-arms which receive effluents from the micro-liquid chromatograph and the gas chromatograph. The dual nature of this chromatographic system offers: (1) extreme flexibility in the samples to be examined; (2) extreme low sensitivity; (3) element selectivity; (4) long-term stability; (5) direct correlation of data from the liquid and gas samples; (6) simpler operation than with individual liquid and gas chromatographs, each with different detection systems; and (7) cheaper than a commercial liquid chromatograph and a gas chromatograph.

  8. Versatile gas/particle ion chromatograph.

    PubMed

    Ullah, S M Rahmat; Takeuchi, Masaki; Dasgupta, Purnendu K

    2006-02-01

    A new, compact gas/particle ion chromatograph has been developed for measuring ionic constituents in PM2.5 (particulate matter of aerodynamic diameter < or = 2.5 microm) and water-soluble ionogenic gases. The instrument has separate sampling channels for gases and particles. In one, a membrane denuder collects soluble gases for preconcentration and analysis. In the other, a cyclone removes larger particles, a membrane denuder removes soluble gases, and a continuously wetted hydrophilic filter collects particles. A single, multiport, syringe pump handles liquid transport, and one conductivity detector measures anions and ammonium for both channels. Electrodialytically generated gradient hydroxide eluent permits 20 min chromatographic runs. Gas/particle samples are each collected for 40 min, butthe sampling intervals are staggered by 20 min. Liquid samples from the gas denuder and particle collector are aspirated and preconcentrated on sequential cation and anion concentrators and transferred respectively to an ammonia transfer device and an anion separation column. The flow configuration results in an ammonium peak before anion peaks in the chromatogram. The system measures ammonia, organic acids (such as acetic, formic, and oxalic acids), HCl, HONO, SO2, HNO3, and the corresponding ions in the aerosol phase. Low ng/m3 to sub-ng/m3 limits of detection (LODs) are attained for most common gases and particulate constituents, the LODs for gaseous SO2 to NH3 range, for example, from sub parts per trillion by volume (sub-pptv) to approximately 5 pptv.

  9. Versatile gas/particle ion chromatograph.

    PubMed

    Ullah, S M Rahmat; Takeuchi, Masaki; Dasgupta, Purnendu K

    2006-02-01

    A new, compact gas/particle ion chromatograph has been developed for measuring ionic constituents in PM2.5 (particulate matter of aerodynamic diameter < or = 2.5 microm) and water-soluble ionogenic gases. The instrument has separate sampling channels for gases and particles. In one, a membrane denuder collects soluble gases for preconcentration and analysis. In the other, a cyclone removes larger particles, a membrane denuder removes soluble gases, and a continuously wetted hydrophilic filter collects particles. A single, multiport, syringe pump handles liquid transport, and one conductivity detector measures anions and ammonium for both channels. Electrodialytically generated gradient hydroxide eluent permits 20 min chromatographic runs. Gas/particle samples are each collected for 40 min, butthe sampling intervals are staggered by 20 min. Liquid samples from the gas denuder and particle collector are aspirated and preconcentrated on sequential cation and anion concentrators and transferred respectively to an ammonia transfer device and an anion separation column. The flow configuration results in an ammonium peak before anion peaks in the chromatogram. The system measures ammonia, organic acids (such as acetic, formic, and oxalic acids), HCl, HONO, SO2, HNO3, and the corresponding ions in the aerosol phase. Low ng/m3 to sub-ng/m3 limits of detection (LODs) are attained for most common gases and particulate constituents, the LODs for gaseous SO2 to NH3 range, for example, from sub parts per trillion by volume (sub-pptv) to approximately 5 pptv. PMID:16509343

  10. A Quantitative Gas Chromatographic Ethanol Determination.

    ERIC Educational Resources Information Center

    Leary, James J.

    1983-01-01

    Describes a gas chromatographic experiment for the quantitative determination of volume percent ethanol in water ethanol solutions. Background information, procedures, and typical results are included. Accuracy and precision of results are both on the order of two percent. (JN)

  11. 40 CFR 1065.267 - Gas chromatograph.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Gas chromatograph. 1065.267 Section 1065.267 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Hydrocarbon Measurements § 1065.267 Gas...

  12. 40 CFR 1065.267 - Gas chromatograph.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Gas chromatograph. 1065.267 Section 1065.267 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Hydrocarbon Measurements § 1065.267 Gas...

  13. Portable gas chromatograph-mass spectrometer

    DOEpatents

    Andresen, Brian D.; Eckels, Joel D.; Kimmons, James F.; Myers, David W.

    1996-01-01

    A gas chromatograph-mass spectrometer (GC-MS) for use as a field portable organic chemical analysis instrument. The GC-MS is designed to be contained in a standard size suitcase, weighs less than 70 pounds, and requires less than 600 watts of electrical power at peak power (all systems on). The GC-MS includes: a conduction heated, forced air cooled small bore capillary gas chromatograph, a small injector assembly, a self-contained ion/sorption pump vacuum system, a hydrogen supply, a dual computer system used to control the hardware and acquire spectrum data, and operational software used to control the pumping system and the gas chromatograph. This instrument incorporates a modified commercial quadrupole mass spectrometer to achieve the instrument sensitivity and mass resolution characteristic of laboratory bench top units.

  14. Portable gas chromatograph-mass spectrometer

    DOEpatents

    Andresen, B.D.; Eckels, J.D.; Kimmons, J.F.; Myers, D.W.

    1996-06-11

    A gas chromatograph-mass spectrometer (GC-MS) is described for use as a field portable organic chemical analysis instrument. The GC-MS is designed to be contained in a standard size suitcase, weighs less than 70 pounds, and requires less than 600 watts of electrical power at peak power (all systems on). The GC-MS includes: a conduction heated, forced air cooled small bore capillary gas chromatograph, a small injector assembly, a self-contained ion/sorption pump vacuum system, a hydrogen supply, a dual computer system used to control the hardware and acquire spectrum data, and operational software used to control the pumping system and the gas chromatograph. This instrument incorporates a modified commercial quadrupole mass spectrometer to achieve the instrument sensitivity and mass resolution characteristic of laboratory bench top units. 4 figs.

  15. Portable gas chromatograph-mass spectrometer

    SciTech Connect

    Andresen, B.D.; Eckels, J.D.; Kimmins, J.F.; Myers, D.W.

    1994-12-31

    A gas chromatograph-mass spectrometer (GC-MS) for use as a field portable organic chemical analysis instrument. The GC-MS is designed to be contained in a standard size suitcase, weighs less than 70 pounds, and requires less than 600 watts of electrical power at peak power (all systems on). The GC-MS includes: a conduction heated, forced air cooled small bore capillary gas chromatograph, a small injector assembly, a self-contained ion/sorption pump vacuum system, a hydrogen supply, a dual computer system used to control the hardware and acquire spectrum data, and operational software used to control the pumping system and the gas chromatograph. This instrument incorporates a modified commercial quadrupole mass spectrometer to achieve the instrument sensitivity and mass resolution characteristic of laboratory bench top units.

  16. Hand-held multiple system gas chromatograph

    DOEpatents

    Yu, Conrad M.

    2001-01-01

    A multiple parallel hand-held gas chromatograph (GC) system which includes several independent GCs. Each independent GC has its own injector, separation column, detector and oven and the GCs are mounted in a light weight hand-held assembly. Each GC operates independently and simultaneously. Because of different coatings in different separation columns, different retention times for the same gas will be measured. Thus, for a GC system with multiple parallel GCs, the system can measure, in a short period, different retention times and provide a cross-reference in the determination of the measured gas and to become a two-dimensional system for direct field use.

  17. Detection system for a gas chromatograph

    DOEpatents

    Hayes, John M.; Small, Gerald J.

    1984-01-01

    A method and apparatus are described for the quantitative analysis of vaporizable compounds, and in particular of polycyclic aromatic hydrocarbons which may be induced to fluoresce. The sample to be analyzed is injected into a gas chromatography column and is eluted through a narrow orifice into a vacuum chamber. The free expansion of the eluted sample into the vacuum chamber creates a supersonic molecular beam in which the sample molecules are cooled to the extent that the excited vibrational and rotational levels are substantially depopulated. The cooled molecules, when induced to fluoresce by laser excitation, give greatly simplified spectra suitable for analytical purposes. The laser induced fluorimetry provides great selectivity, and the gas chromatograph provides quantitative transfer of the sample to the molecular beam.

  18. FTIR gas chromatographic analysis of perfumes

    NASA Astrophysics Data System (ADS)

    Diederich, H.; Stout, Phillip J.; Hill, Stephen L.; Krishnan, K.

    1992-03-01

    Perfumes, natural or synthetic, are complex mixtures consisting of numerous components. Gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS) techniques have been extensively utilized for the analysis of perfumes and essential oils. A limited number of perfume samples have also been analyzed by FT-IR gas chromatographic (GC-FTIR) techniques. Most of the latter studies have been performed using the conventional light pipe (LP) based GC-FTIR systems. In recent years, cold-trapping (in a matrix or neat) GC-FTIR systems have become available. The cold-trapping systems are capable of sub-nanogram sensitivities. In this paper, comparison data between the LP and the neat cold-trapping GC- FTIR systems is presented. The neat cold-trapping interface is known as Tracer. The results of GC-FTIR analysis of some commercial perfumes is also presented. For comparison of LP and Tracer GC-FTIR systems, a reference (synthetic) mixture containing 16 major and numerous minor constituents was used. The components of the mixture are the compounds commonly encountered in commercial perfumes. The GC-FTIR spectra of the reference mixture was obtained under identical chromatographic conditions from an LP and a Tracer system. A comparison of the two sets of data thus generated do indeed show the enhanced sensitivity level of the Tracer system. The comparison also shows that some of the major components detected by the Tracer system were absent from the LP data. Closer examination reveals that these compounds undergo thermal decomposition on contact with the hot gold surface that is part of the LP system. GC-FTIR data were obtained for three commercial perfume samples. The major components of these samples could easily be identified by spectra search against a digitized spectral library created using the Tracer data from the reference mixture.

  19. Fast gas chromatographic separation of biodiesel.

    SciTech Connect

    Pauls, R. E.

    2011-05-01

    A high-speed gas chromatographic method has been developed to determine the FAME distribution of B100 biodiesel. The capillary column used in this work has dimensions of 20 m x 0.100 mm and is coated with a polyethylene glycol film. Analysis times are typically on the order of 4-5 min depending upon the composition of the B100. The application of this method to a variety of vegetable and animal derived B100 is demonstrated. Quantitative results obtained with this method were in close agreement with those obtained by a more conventional approach on a 100 m column. The method, coupled with solid-phase extraction, was also found suitable to determine the B100 content of biodiesel-diesel blends.

  20. Gas Chromatographic Detectors for Exobiology Flight Experiments

    NASA Technical Reports Server (NTRS)

    Kojiro, Daniel R.; Humphry, Donald E.; Takeuchi, Nori; Chang, Sherwood (Technical Monitor)

    1997-01-01

    Exobiology flight experiments require highly sensitive instrumentation for in situ chemical analysis of the volatile chemical species that occur in the atmospheres and surfaces of various bodies within the solar system. The complex mixtures encountered place a heavy burden on the analytical instrumentation to detect and identify all species present. Future missions to Mars', comets, or planetary moons such as Europa, will perform experiments with complex analyses. In addition, instrumentation for such missions must perform under severely restricted conditions with limited resources. To meet these analytical requirements, improved methods and highly sensitive yet smaller instruments must continually be developed with increasingly greater capabilities. We describe here efforts to achieve this objective, for past and future missions, through the development of new or the improvement of existing sensitive, miniaturized gas chromatographic detectors.

  1. Gas-Chromatographic Determination Of Water In Freon PCA

    NASA Technical Reports Server (NTRS)

    Melton, Donald M.

    1994-01-01

    Gas-chromatographic apparatus measures small concentrations of water in specimens of Freon PCA. Testing by use of apparatus faster and provides greater protection against accidental contamination of specimens by water in testing environment. Automated for unattended operation. Also used to measure water contents of materials, other than Freon PCA. Innovation extended to development of purgeable sampling accessory for gas chromatographs.

  2. First-generation hybrid MEMS gas chromatograph.

    PubMed

    Lu, Chia-Jung; Steinecker, William H; Tian, Wei-Cheng; Oborny, Michael C; Nichols, Jamie M; Agah, Masoud; Potkay, Joseph A; Chan, Helena K L; Driscoll, Jeffrey; Sacks, Richard D; Wise, Kensall D; Pang, Stella W; Zellers, Edward T

    2005-10-01

    The fabrication, assembly, and initial testing of a hybrid microfabricated gas chromatograph (microGC) is described. The microGC incorporates capabilities for on-board calibration, sample preconcentration and focused thermal desorption, temperature-programmed separations, and "spectral" detection with an integrated array of microsensors, and is designed for rapid determinations of complex mixtures of environmental contaminants at trace concentrations. Ambient air is used as the carrier gas to avoid the need for on-board gas supplies. The microsystem is plumbed through an etched-Si/glass microfluidic interconnection substrate with fused silica capillaries and employs a miniature commercial pump and valve subsystem for directing sample flow. The latest performance data on each system component are presented followed by first analytical results from the working microsystem. Tradeoffs in system performance as a function of volumetric flow rate are explored. The determination of an 11-vapor mixture of typical indoor air contaminants in less than 90 s is demonstrated with projected detection limits in the low part-per-billion concentration range for a preconcentrated air-sample volume of 0.25 L.

  3. High performance hand-held gas chromatograph

    SciTech Connect

    Yu, C M; Koo, J C

    2001-01-10

    Gas chromatography is a prominent technique for separating complex gases and then analyzing the relative quantities of the separate components. This analytical technique is popular with scientists in a wide range of applications, including environmental restoration for air and water pollution, and chemical and biological analysis. Today the analytical instrumentation community is to working towards moving the analysis away from the laboratory to the point of origin of the sample (''the field'') to achieve real-time data collection and lower analysis costs. The Microtechnology Center of Lawrence Livermore National Laboratory, has developed a hand-held, real-time detection gas chromatograph (GC) through Micro-Electro-Mechanical-System (MEMS) technology. The total weight of this GC is approximately 8 pounds, and it measures 8 inches by 5 inches by 3 inches. It consumes approximately 12 watts of electrical power and has a response time on the order of 2 minutes. The current detector is a glow discharge detector with a sensitivity of parts per billion. The average retention time is about 30 to 45 seconds. Under optimum conditions, the calculated effective plate number is 40,000. The separation column in the portable GC is fabricated completely on silicon wafers. Silicon is a good thermal conductor and provides rapid heating and cooling of the column. The operational temperature can be as high as 350 degrees Celsius. The GC system is capable of rapid column temperature ramping and cooling operations. These are especially important for organic and biological analyses in the GC applications.

  4. Emergency gas-chromatographic assay of phenobarbital and phenytoin and liquid-chromatographic assay of theophylline.

    PubMed

    Shihabi, Z K

    1978-09-01

    Phenobarbital and phenytoin are extracted and concentrated in a single step, without solvent evaporation, followed by on-column methylation and gas-chromatographic quanitation. A similar extraction step for the assay of theophylline by high-pressure liquid chromatography is described. The extraction step can be completed in less than 2 min, the chromatographic step in less than 8 min. This extraction method yields clean chromatograms, avoids evaporating health-hazardous solvents, and is applicable to other drugs.

  5. Gas Chromatographic Determination of Enrivonmentally Significant Pesticides.

    ERIC Educational Resources Information Center

    Rudzinski, Walter E.; Beu, Steve

    1982-01-01

    A chromatographic procedure for analyzing organophosphorus pesticides (such as PCB's, nitrosamines, and phthalate esters) in orange juice is described, including a summary of the method, instrumentation, methodology, results/discussion, and calculations. (JN)

  6. GAS CHROMATOGRAPHIC TECHNIQUES FOR THE MEASUREMENT OF ISOPRENE IN AIR

    EPA Science Inventory

    The chapter discusses gas chromatographic techniques for measuring isoprene in air. Such measurement basically consists of three parts: (1) collection of sufficient sample volume for representative and accurate quantitation, (2) separation (if necessary) of isoprene from interfer...

  7. AEROSOL AND GAS MEASUREMENT

    EPA Science Inventory

    Measurements provide fundamental information for evaluating and managing the impact of aerosols on air quality. Specific measurements of aerosol concentration and their physical and chemical properties are required by different users to meet different user-community needs. Befo...

  8. An on-line calibration method for process gas chromatographs

    SciTech Connect

    Fang, M.; Wang, F.

    1995-05-01

    Gas chromatographs (GCs) used to measure gas concentrations in process streams usually need calibration for a wide range of concentrations. The gas chromatographs used in process applications are usually equipped with automatic samplers using sample loops. The sampling system can be modified to provide on-line calibration, by adding a vacuum system and a precision pressure gage. In this paper, the authors describe a method using pure gases for the calibration of automatic GCs by varying and measuring precisely the pressure of the sample loop, thus sending known quantities of gas into the column. The concentration of the gas is calculated using the ideal gas law, and they are able to calibrate GCs in a range from 1,000 ppm to 100 vol %.

  9. Derivatization procedure for gas chromatographic determination of hydroxylamine

    SciTech Connect

    Pesselman, R.L.; Foral, M.J.; Langer, S.H.

    1987-04-15

    Hydroxylamine has been of special interest recently because of the possibilities of manufacturing it by using electrochemical methods in which ammonia might also be formed. Its general chemistry and applications have been described elsewhere. Presently, there are two gas chromatographic methods reported for the determination of hydroxylamine in aqueous media. The first involves reacting the hydroxylamine to form acetone oxime and subsequently injecting the aqueous solution directly into a gas chromatograph equipped with nitrogen and flame ionization detectors. The second involves oxidizing hydroxylamine to nitrous oxide and trapping the gas for determination in an electron capture equipped gas chromatograph. Limits of detection are in the micromolar range for the former and the nanomolar range for the latter. Here, an alternate gas chromatographic procedure for determining hydroxylamine as the acetone oxime is described. Neither direct aqueous injection nor elaborate instrumentation is required. Extraction of the oxime into an ether phase allows for concentrating the analyte ad facilitates the use of an internal standard. The limitations and inconveniences of direct aqueous injection are avoided included column degradation and filament burnout in mass spectrometry detectors.

  10. Gas chromatographic analysis of volatiles in fluid and gas inclusions.

    PubMed

    Andrawes, F; Holzer, G; Roedder, E; Gibson, E K; Oro, J

    1984-01-01

    Most geological samples and some synthetic materials contain fluid inclusions. These inclusions preserve for us tiny samples of the liquid and/or the gas phase that was present during formation, although in some cases they may have undergone significant changes from the original material. Studies of the current composition of the inclusions provide data on both the original composition and the change since trapping. These conclusions are seldom larger than 1 millimeter in diameter. The composition varies from a single major compound (e.g., water) in a single phase to a very complex mixture in one or more phases. The concentration of some of the compounds present may be at trace levels. We present here some analyses of inclusion on a variety of geological samples, including diamonds. We used a sample crusher and a gas chromatography-mass spectrometry (GC-MS) system to analyze for organic and inorganic volatiles present as major to trace constituents in inclusions. The crusher is a hardened stainless-steel piston cylinder apparatus with tungsten carbide crushing surfaces, and is operated in a pure helium atmosphere at a controlled temperature. Samples ranging from 1 mg to 1 g were crushed and the released volatiles were analyzed using multi-chromatographic columns and detectors, including the sensitive helium ionization detector. Identification of the GC peaks was carried out by GC-MS. This combination of procedures has been shown to provide geochemically useful information on the processes involved in the history of the samples analyzed. PMID:11541990

  11. Gas chromatographic analysis of volatiles in fluid and gas inclusions

    USGS Publications Warehouse

    Andrawes, F.; Holzer, G.; Roedder, E.; Gibson, E.K.; Oro, J.

    1984-01-01

    Most geological samples and some synthetic materials contain fluid inclusions. These inclusions preserve for us tiny samples of the liquid and/or the gas phase that was present during formation, although in some cases they may have undergone significant changes from the original material. Studies of the current composition of the inclusions provide data on both the original composition and the change since trapping. These inclusions are seldom larger than 1 millimeter in diameter. The composition varies from a single major compound (e.g., water) in a single phase to a very complex mixture in one or more phases. The concentration of some of the compounds present may be at trace levels. We present here some analyses of inclusions in a variety of geological samples, including diamonds. We used a sample crusher and a gas chromatography-mass spectrometry (GC-MS) system to analyze for organic and inorganic volatiles present as major to trace constituents in inclusions. The crusher is a hardened stainless-steel piston cylinder apparatus with tungsten carbide crusing surfaces, and is operated in a pure helium atmosphere at a controlled temperature. Samples ranging from 1 mg to 1 g were crushed and the released volatiles were analyzed using multi-chromatographic columns and detectors, including the sensitive helium ionization detector. Identification of the GC peaks was carried out by GC-MS. This combination of procedures has been shown to provide geochemically useful information on the process involved in the history of the samples analyzed. ?? 1984.

  12. [Gas chromatographic analysis of benzodiazepines. 2. Diazepam and its metabolites].

    PubMed

    Heidbrink, V V; Mallach, H J; Moosmayer, A

    1975-04-01

    A gas-chromatographic method is reported which completely resolves diazepam and its major metabolites and thus enables the specific quantitation of these compounds after extraction from serum and urine. The sensitivity limits are about 3 ng/ml if 4 ml serum or urine are extracted.

  13. Dynamic technique for measuring adsorption in a gas chromatograph

    NASA Technical Reports Server (NTRS)

    Deuel, C. L.; Hultgren, N. W.; Mobert, M. L.

    1973-01-01

    Gas-chromatographic procedure, together with mathematical analysis of adsorption isotherm, allows relative surface areas and adsorptive powers for trace concentrations to be determined in a few minutes. Technique may be used to evaluate relative surface areas of different adsorbates, expressed as volume of adsorbent/gram of adsorbate, and to evaluate their relative adsorptive power.

  14. Gas-liquid chromatographic determination of morphine, heroin, and cocaine.

    PubMed

    Prager, M J; Harrington, S M; Governo, T F

    1979-03-01

    Morphine, heroin, and cocaine are quantitatively determined with the same gas-liquid chromatographic system. The compounds are separated on a 6 ft X 2 mm id glass column packed with a 1:1 mixture of 5% SE-30 on 80--100 mesh Chromosorb W and 3% OV-17 on 80--100 mesh Varaport 30. The column is temperature-programmed. Flame ionization detector responses are measured with a computer-based data system. Heroin and cocaine are chromatographed directly; morphine is derivatized first. The procedure was evaluated with previously analyzed commercial and forensic samples. Accuracy and precision were 5 and 3%, respectively. PMID:447602

  15. First Results From the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

    NASA Technical Reports Server (NTRS)

    Niemann, Hasso B.; Demick, J.; Haberman, J.; Harpold, D.; Kasprzak, W.; Raaen, E.; Way, S.; Atreya, S.; Carignan, G.; Bauer, S.

    2005-01-01

    The Huygens Probe of the Cassini Huygens Mission entered the atmosphere of the moon Titan on January 14,2005. The GCMS was part of the instrument complement on the Probe to measure in situ the chemical composition of the atmosphere during the probe descent and to support the Aerosol Collector Pyrolyser (ACP) experiment by serving as detector for the pyrolization products. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns. The mass spectrometer employed five electron impact ion sources with available electron energies of either 70 or 25 eV. Three ion sources served as detectors for the GC columns and two were dedicated to direct atmosphere sampling and ACP gas sampling, respectively. The GCMS gas inlet was heated to prevent condensation, and served to evaporate surface constituents after impact.

  16. Multiplex gas chromatography: an alternative concept for gas chromatographic analysis of planetary atmospheres

    NASA Technical Reports Server (NTRS)

    Valentin, J. R.

    1989-01-01

    Gas chromatography (GC) is a powerful technique for analyzing gaseous mixtures. Applied to the earth's atmosphere, GC can be used to determine the permanent gases--such as carbon dioxide, nitrogen, and oxygen--and to analyze organic pollutants in air. The U.S. National Aeronautics and Space Administration (NASA) has used GC in spacecraft missions to Mars (the Viking Biology Gas Exchange Experiment [GEX] and the Viking Gas Chromatograph-Mass Spectrometer [GC-MS]) and to Venus (the Pioneer Venus Gas Chromatograph [PVGC] on board the Pioneer Venus sounder probe) for determining the atmospheric constituents of these two planets. Even though conventional GC was very useful in the Viking and Pioneer missions, spacecraft constraints and limitations intrinsic to the technique prevented the collection of more samples. With the Venus probe, for instance, each measurement took a relatively long time to complete (10 min), and successive samples could not be introduced until the previous samples had left the column. Therefore, while the probe descended through the Venusian atmosphere, only three samples were acquired at widely separated altitudes. With the Viking mission, the sampling rate was not a serious problem because samples were acquired over a period of one year. However, the detection limit was a major disadvantage. The GC-MS could not detect simple hydrocarbons and simple alcohols below 0.1 ppm, and the GEX could not detect them below 1 ppm. For more complex molecules, the detection limits were at the parts-per-billion level for both instruments. Finally, in both the Viking and Pioneer missions, the relatively slow rate of data acquisition limited the number of analyses, and consequently, the amount of information returned. Similar constraints are expected in future NASA missions. For instance, gas chromatographic instrumentation is being developed to collect and analyze organic gases and aerosols in the atmosphere of Titan (one of Saturn's satellites). The Titan

  17. Multiplex gas chromatography: an alternative concept for gas chromatographic analysis of planetary atmospheres.

    PubMed

    Valentin, J R

    1989-03-01

    Gas chromatography (GC) is a powerful technique for analyzing gaseous mixtures. Applied to the earth's atmosphere, GC can be used to determine the permanent gases--such as carbon dioxide, nitrogen, and oxygen--and to analyze organic pollutants in air. The U.S. National Aeronautics and Space Administration (NASA) has used GC in spacecraft missions to Mars (the Viking Biology Gas Exchange Experiment [GEX] and the Viking Gas Chromatograph-Mass Spectrometer [GC-MS]) and to Venus (the Pioneer Venus Gas Chromatograph [PVGC] on board the Pioneer Venus sounder probe) for determining the atmospheric constituents of these two planets. Even though conventional GC was very useful in the Viking and Pioneer missions, spacecraft constraints and limitations intrinsic to the technique prevented the collection of more samples. With the Venus probe, for instance, each measurement took a relatively long time to complete (10 min), and successive samples could not be introduced until the previous samples had left the column. Therefore, while the probe descended through the Venusian atmosphere, only three samples were acquired at widely separated altitudes. With the Viking mission, the sampling rate was not a serious problem because samples were acquired over a period of one year. However, the detection limit was a major disadvantage. The GC-MS could not detect simple hydrocarbons and simple alcohols below 0.1 ppm, and the GEX could not detect them below 1 ppm. For more complex molecules, the detection limits were at the parts-per-billion level for both instruments. Finally, in both the Viking and Pioneer missions, the relatively slow rate of data acquisition limited the number of analyses, and consequently, the amount of information returned. Similar constraints are expected in future NASA missions. For instance, gas chromatographic instrumentation is being developed to collect and analyze organic gases and aerosols in the atmosphere of Titan (one of Saturn's satellites). The Titan

  18. Gas chromatographic characterization of vegetable oil deodorization distillate.

    PubMed

    Verleyen, T; Verhe, R; Garcia, L; Dewettinck, K; Huyghebaert, A; De Greyt, W

    2001-07-01

    Because of its complex nature, the analysis of deodorizer distillate is a challenging problem. Deodorizer distillate obtained from the deodorization process of vegetable oils consists of many components including free fatty acids, tocopherols, sterols, squalene and neutral oil. A gas chromatographic method for the analysis of deodorizer distillate without saponification of the sample is described. After a concise sample preparation including derivatization and silylation, distillate samples were injected on column at 60 degrees C followed by a gradual increase of the oven temperature towards 340 degrees C. The temperature profile of the oven was optimized in order to obtain a baseline separation of the different distillate components including free fatty acids, tocopherols, sterols, squalene and neutral oil. Good recoveries for delta-tocopherol, alpha-tocopherol, stigmasterol and cholesteryl palmitate of 97, 94.4, 95.6 and 92%, respectively were obtained. Repeatability of the described gas chromatographic method was evaluated by analyzing five replicates of a soybean distillate. Tocopherols and sterols had low relative standard deviations ranging between 1.67 and 2.25%. Squalene, mono- and diacylglycerides had higher relative standard deviations ranging between 3.33 and 4.12%. Several industrial deodorizer distillates obtained from chemical and physical refining of corn, canola, sunflower and soybean have been analyzed for their composition.

  19. Gas chromatographic characterization of vegetable oil deodorization distillate.

    PubMed

    Verleyen, T; Verhe, R; Garcia, L; Dewettinck, K; Huyghebaert, A; De Greyt, W

    2001-07-01

    Because of its complex nature, the analysis of deodorizer distillate is a challenging problem. Deodorizer distillate obtained from the deodorization process of vegetable oils consists of many components including free fatty acids, tocopherols, sterols, squalene and neutral oil. A gas chromatographic method for the analysis of deodorizer distillate without saponification of the sample is described. After a concise sample preparation including derivatization and silylation, distillate samples were injected on column at 60 degrees C followed by a gradual increase of the oven temperature towards 340 degrees C. The temperature profile of the oven was optimized in order to obtain a baseline separation of the different distillate components including free fatty acids, tocopherols, sterols, squalene and neutral oil. Good recoveries for delta-tocopherol, alpha-tocopherol, stigmasterol and cholesteryl palmitate of 97, 94.4, 95.6 and 92%, respectively were obtained. Repeatability of the described gas chromatographic method was evaluated by analyzing five replicates of a soybean distillate. Tocopherols and sterols had low relative standard deviations ranging between 1.67 and 2.25%. Squalene, mono- and diacylglycerides had higher relative standard deviations ranging between 3.33 and 4.12%. Several industrial deodorizer distillates obtained from chemical and physical refining of corn, canola, sunflower and soybean have been analyzed for their composition. PMID:11471811

  20. Improving the gas-chromatographic determination of the composition of the gas liberated from a battery

    SciTech Connect

    Dmitriev, V.V.; Zubov, M.S.; Baulov, V.I.; Toguzov, B.M.

    1992-07-10

    Normally, gas chromatography is used for analyzing the gas composition that is liberated when batteries operate. Earlier work describes a gas-chromatographic technique for determining the composition of gas liberated from a battery. According to this reference, the gas is collected in an inverted burette over water. The gas is either sampled with a batching valve or with a medical syringe, which pierces the connecting vacuum hoses. The gas sample is injected into the chromatographic evaporator, and is separated on the chromatographic column into its individual components, each of which is analyzed on the detector. The method described was used to study gas liberation during the storage of charged nickel-zinc batteries. In the method described above, a high proportion of the gas specimen that accumulates and is collected in the measuring system occurs in the dead space volume. In this situation, it is very difficult to determine the liberated gas composition with a high degree of accuracy when the gas is liberated at low rates. Moreover, this method does not provide reliable system air tightness during long term operation of the batteries. 5 refs., 2 figs., 1 tab.

  1. Gas chromatographic determination of cyclohexanone leached from hemodialysis tubing.

    PubMed

    Snell, R P

    1993-01-01

    A capillary gas chromatographic procedure is described for the determination of cyclohexanone leached from hemodialysis tubing by water. Recoveries were 100% at 2.0 mg/100 mL (20 ppm), 99.0% at 500 microg/100 mL (5 ppm), and 106% at 1.0 microg/100 mL (10 ppb). Reproducibility of the system was 0.152% for 3.0 microL injections of a solution containing cyclohexanone at 5.58 microg/mL. Correlation coefficients were 0.9983 for 0.3672-3.672 ng and 1.0000 for 3.672-367.2 ng. Twenty hemodialysis tubing sets from 4 manufacturers were examined. The leachable cyclohexanone ranged from 1.02 to 43.7 ppm per set. Rinsing the tubing with 1 L 0.9% sodium chloride solution did not remove significant amounts (P = 0.05) of leachable cyclohexanone.

  2. The gas chromatographic resolution of DL-isovaline

    NASA Technical Reports Server (NTRS)

    Flores, J. J.; Bonner, W. A.; Van Dort, M. A.

    1977-01-01

    Isovaline is of cosmological interest because it is one of the 12 non-protein amino acids which have been isolated from the Murchison meteorite, and unlike the other chiral amino acids in this meteorite, it has no alpha-hydrogen at its asymmetric center and hence cannot racemize by the customary alpha-hydrogen-dependent mechanisms which engender racemization in ordinary amino acids. Experiments were conducted in which a .01 M solution of N-TFA-DL-isovalyl-L-leucine isopropyl ester in nitromethane was injected into the capillary column of a gas chromatograph coupled to a digital electronic integrator-recorder. Efflux times and integrated peak area percents are shown next to each diastereometer peak.

  3. Fatty acids determination in Bronte pistachios by gas chromatographic method.

    PubMed

    Pantano, Licia; Lo Cascio, Giovanni; Alongi, Angelina; Cammilleri, Gaetano; Vella, Antonio; Macaluso, Andrea; Cicero, Nicola; Migliazzo, Aldo; Ferrantelli, Vincenzo

    2016-10-01

    A gas chromatographic with flame ionization detector (GC-MS FID) method for the identification and quantification of fatty acids based on the extraction of lipids and derivatisation of free acids to form methyl esters was developed and validated. The proposed method was evaluated to a number of standard FAs, and Bronte pistachios samples were used for that purpose and to demonstrate the applicability of the proposed method. In this regard, repeatability, mean and standard deviation of the analytical procedure were calculated. The results obtained have demonstrated oleic acid as the main component of Bronte pistachios (72.2%) followed by linoleic acid (13.4%) and showed some differences in composition with respect to Tunisian, Turkish and Iranian pistachios.

  4. Fatty acids determination in Bronte pistachios by gas chromatographic method.

    PubMed

    Pantano, Licia; Lo Cascio, Giovanni; Alongi, Angelina; Cammilleri, Gaetano; Vella, Antonio; Macaluso, Andrea; Cicero, Nicola; Migliazzo, Aldo; Ferrantelli, Vincenzo

    2016-10-01

    A gas chromatographic with flame ionization detector (GC-MS FID) method for the identification and quantification of fatty acids based on the extraction of lipids and derivatisation of free acids to form methyl esters was developed and validated. The proposed method was evaluated to a number of standard FAs, and Bronte pistachios samples were used for that purpose and to demonstrate the applicability of the proposed method. In this regard, repeatability, mean and standard deviation of the analytical procedure were calculated. The results obtained have demonstrated oleic acid as the main component of Bronte pistachios (72.2%) followed by linoleic acid (13.4%) and showed some differences in composition with respect to Tunisian, Turkish and Iranian pistachios. PMID:27265004

  5. Gas chromatograph-mass spectrometer (GC/MS) system for quantitative analysis of reactive chemical compounds

    DOEpatents

    Grindstaff, Quirinus G.

    1992-01-01

    Described is a new gas chromatograph-mass spectrometer (GC/MS) system and method for quantitative analysis of reactive chemical compounds. All components of such a GC/MS system external to the oven of the gas chromatograph are programmably temperature controlled to operate at a volatilization temperature specific to the compound(s) sought to be separated and measured.

  6. Chemical characterization of Brickellia cavanillesii (Asteraceae) using gas chromatographic methods.

    PubMed

    Eshiet, Etetor R; Zhu, Jinqiu; Anderson, Todd A; Smith, Ernest E

    2014-03-01

    A methanol extract of lyophilized Brickellia cavanillesii was quantitatively analyzed using gas chromatographic (GC) techniques. The chromatographic methods employed were (i) GC-flame ionization detector (GC-FID), (ii) GC-mass spectrometry (GC-MS), and (iii) purge and trap GC-MS (P&T GC-MS). Thirteen compounds were identified with a quality match of 90% and above using GC-MS. The compounds were (1) Cyclohexene, 6-ethenyl-6-methyl-1-(1-methylethyl)-3-(1-methylethylidene)-, (S)-; (2) Bicylo (2.2.1) heptan-2-one, 1, 7, 7-trimethyl-(1S, 4S)-; (3) Phenol, 2-methoxy-4-(1-propenyl)-; (4) Benzene, 1-(1, 5-dimethyl-4-hexenyl)-4-methyl-; (5) Naphthalene, 1, 2, 3, 5, 6, 8a-hexahydro4, 7-dimethyl-1-1-(1-methylethyl)-, (1S-cis)-; (6) Phenol, 2-methoxy-; (7) Benzaldehyde, 3-hydroxy-4-methoxy-; (8) 11, 13-Eicosadienoic acid, methyl ester; (9) 2-Furancarboxaldehyde, 5-methyl-; (10) Maltol; (11) Phenol; (12) Hydroquinone; (13) 1H-Indene, 1-ethylideneoctahydro-7a-methyl-, (1E, 3a.alpha, 7a.beta.). Other compounds (14) 3-methyl butanal; (15) (D)-Limonene; (16) 1-methyl-4-(1-methyl ethyl) benzene; (17) Butanoic acid methyl ester; (18) 2-methyl propanal; (19) 2-butanone; (20) 2-pentanone; and (21) 2-methyl butane were also identified when P&T GC-MS was performed. Of the 21 compounds identified, 12 were validated using chemical standards. The identified compounds were found to be terpenes, derivatives of terpenes, esters, ketones, aldehydes, and phenol-derived aromatic compounds; these are the primary constituents of the essential oils of many plants and flowers. PMID:24804069

  7. The Huygens Gas Chromatograph Mass Spectrometer Investigation Of Titan

    NASA Astrophysics Data System (ADS)

    Atreya, Sushil; Harpold, Dan; Owen, Tobias

    2015-04-01

    A decade ago, on 14 January 2005, the Huygens probe of the Cassini-Huygens mission descended through the smog filled atmosphere of Titan and landed on the surface, revealing for the first time the extraordinary nature of Saturn's largest moon. One of the six payload instruments, the gas chromatograph mass spectrometer (GCMS), was crucial for measuring the composition of the atmosphere and the surface of Titan [1,2]. Most of the GCMS findings were "firsts", including the first direct identification of molecular nitrogen as the bulk constituent of the atmosphere, first vertical profile of Titan's second most abundant volatile, methane, first determination of primordial and radiogenic argon, first quantification of a number of stable gas isotopes, and the first measurements of the make-up of Titan's surface. These data are key to understanding why Titan is so unique amongst planetary moons in possessing a massive atmosphere [3], how Titan maintains a cycle of methane complete with surface reservoirs, evaporation and condensation like the hydrological cycle on earth [3,4,5], and what is responsible for the photochemical smog on Titan that plays a central role in the very existence of an atmosphere on Titan [3]. This presentation will discuss the GCMS investigation and how it helped shape our current view of Titan. [website for downloading pdf's of relevant papers: www.umich.edu/~atreya] [1] Niemann, H. B. et al., The abundances of constituents of Titan's atmosphere from the GCMS instrument on the Huygens probe, Nature 438, 779-784, 2005. [2] Niemann, H. B. et al., The composition of Titan's lower atmosphere and simple surface volatiles as measured by the Cassini-Huygens probe gas chromatograph mass spectrometer experiment, J. Geophys. Res. (Planets) 115, 12006, 2010. [3] Atreya S. K., R. D. Lorenz and J. H. Waite, Volatile origin and cycles: Nitrogen and methane, in Titan from Cassini-Huygens, R. H. Brown, J. P. Lebreton and J. Waite, (eds.), Springer Dordrecht

  8. Results from the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

    NASA Technical Reports Server (NTRS)

    Niemann, Hasso; Atreya, S.; Demick-Monelara, J.; Haberman, J.; Harpold, D.; Kasprzak, W.; Owen, T.; Raaen, E.; Way, S.

    2006-01-01

    The Gas Chromatograph Mass Spectrometer was one of six instruments on the Cassini-Huygens Probe mission to Titan. The GCMS measured in situ the chemical composition of the atmosphere during the probe descent and served as the detector for the pyrolization products for the Aerosol Collector Pyrolyser (ACP) experiment to determine the composition of the aerosol particles. The GCMS collected data from an altitude of 146 km to ground impact. The Probe and the GCMS survived impact and collected data for 1 hour and 9 minutes on the surface. Mass spectra were collected during descent and on the ground over a range of mlz from 2 to 141. The major constituents of the lower atmosphere were confirmed to be N2 and CH4. The methane mole fraction was uniform in the stratosphere. It increased below the tropopause, at about 32 km altitude, monotonically toward the surface, reaching a plateau at about 8 km at a level near saturation. After surface impact a steep increase of the methane signal was observed, suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. The measured mole fraction of Ar-40 is 4.3x10(exp -5) and of Ar-36 is 2.8x10(exp -7). The other primordial noble gases were below 10(exp -8) mole fraction. The isotope ratios of C-12/C-13 determined from methane measurements are 82.3 and of N-14/N-15 determined from molecular nitrogen are 183. The D/H isotope ratio determined from the H2 and HD measurements is 2.3x10(exp -4). Carbon dioxide, ethane, acetylene and cyanogen were detected evaporating from the surface in addition to methane. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns, a chemical scrubber and a hydrocarbon enrichment cell. The GCMS gas inlet was heated to prevent condensation, and to evaporate volatiles from the

  9. Results from the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

    NASA Technical Reports Server (NTRS)

    Niemann, H.; Atreya, S.; Demick-Montelara, J.; Haberman, J.; Harpold, D.; Kasprzak, W.; Owen, T.; Raaen, E.; Way, S.

    2006-01-01

    The Gas Chromatograph Mass Spectrometer was one of six instruments on the Cassini-Huygens Probe mission to Titan. The GCMS measured in situ the chemical composition of the atmosphere during the probe descent and served as the detector for the pyrolization products for the Aerosol Collector Pyrolyser (ACP) experiment to determine the composition of the aerosol particles. The GCMS collected data from an altitude of 146 km to ground impact. The Probe and the GCMS survived impact and collected data for 1 hour and 9 minutes on the surface. Mass spectra were collected during descent and on the ground over a range of m/z from 2 to 141. The major constituents of the lower atmosphere were confirmed to be N2 and CH4. The methane mole fraction was uniform in the stratosphere. It increased below the tropopause, at about 32 km altitude, monotonically toward the surface, reaching a plateau at about 8 km at a level near saturation. After surface impact a steep increase of the methane signal was observed, suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. The measured mole fraction of Ar-40 is 4.3x10(exp -5) and of Ar-36 is 2.8x10(exp -7). The other primordial noble gases were below 10(exp -8) mole fraction. The isotope ratios of C-12/C-13 determined from methane measurements are 82.3 and of N-14/N-15 determined from molecular nitrogen are 183. The D/H isotope ratio determined from the H2 and HD measurements is 2.3x10(exp -4). Carbon dioxide, methane, acetylene and cyanogen were detected evaporating from the surface in addition to methane. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns, a chemical scrubber and a hydrocarbon enrichment cell. The GCMS gas inlet was heated to prevent condensation, and to evaporate volatiles from the

  10. Mars Solar Balloon Landed Gas Chromatograph Mass Spectrometer

    NASA Technical Reports Server (NTRS)

    Mahaffy, P.; Harpold, D.; Niemann, H.; Atreya, S.; Gorevan, S.; Israel, G.; Bertaux, J. L.; Jones, J.; Owen, T.; Raulin, F.

    1999-01-01

    A Mars surface lander Gas Chromatograph Mass Spectrometer (GCMS) is described to measure the chemical composition of abundant and trace volatile species and isotope ratios for noble gases and other elements. These measurements are relevant to the study of atmospheric evolution and past climatic conditions. A Micromission plan is under study where a surface package including a miniaturized GCMS would be delivered to the surface by a solar heated hot air balloon based system. The balloon system would be deployed about 8 km above the surface of Mars, wherein it would rapidly fill with Martian atmosphere and be heated quickly by the sun. The combined buoyancy and parachuting effects of the solar balloon result in a surface package impact of about 5 m/sec. After delivery of the package to the surface, the balloon would ascend to about 4 km altitude, with imaging and magnetometry data being taken for the remainder of the daylight hours as the balloon is blown with the Martian winds. Total atmospheric entry mass of this mission is estimated to be approximately 50 kg, and it can fit as an Ariane 5 piggyback payload. The GCMS would obtain samples directly from the atmosphere at the surface and also from gases evolved from solid phase material collected from well below the surface with a Sample Acquisition and Transport Mechanism (SATM). The experiment envisioned in the Mars Micromission described would obtain samples from a much greater depth of up to one meter below the surface, and would search for organic molecules trapped in ancient stratified layers well below the oxidized surface. Insitu instruments on upcoming NASA missions working in concert with remote sensing measurement techniques have the potential to provide a more detailed investigation of mineralogy and the extent of simple volatiles such as CO2 and H2O in surface and subsurface solid phase materials. Within the context of subsequent mission opportunities such as those provided by the Ariane 5 piggyback

  11. Capillary gas chromatographic analysis of pans with luminol chemilumnescent detection

    SciTech Connect

    Gaffney, J.; Bornick, R.; Chen, Yu-Harn; Marley, N.

    1996-12-31

    Peroxyacyl nitrates (PANs) are important air pollutants in tropospheric chemistry. PANs are known to be potent phytotoxins at low ppb concentrations and are lachrymators. They can also transport the more reactive nitrogen dioxide long distances, because they are in equilibrium with that NO{sub x} species. Since PANs are trapped peroxyradicals, they are a direct measure of the peroxyradical levels and the of {open_quotes}photochemical age{close_quotes} of an air parcel. The PANs are typically measured in the atmosphere by using electron capture detection methods. These methods suffer from large background signals and detector responses to oxygen and water vapor. This paper describes the combination of a capillary gas chromatographic column with a modified luminol chemiluminescent nitrogen dioxide detector (Scintrex, Luminox) for rapid and sensitive detection of nitrogen dioxide, peroxyacetyl nitrate, peroxypropionyl nitrate, and peroxybutyryl nitrate. Detection limits for this approach in the low tens of parts per trillion have been observed with total analysis times of less than three minutes. We will discuss the potential application of this method to other compounds, particularly, organonitrates, in a pyrolysis system and/or with ozone addition to the sampling streams.

  12. Characterisation of wax works of art by gas chromatographic procedures.

    PubMed

    Regert, M; Langlois, J; Colinart, S

    2005-10-14

    To identify the various natural and synthetic substances used by sculptors at the end of the 19th century, several contemporary reference samples were investigated by high temperature gas chromatography (HT GC) and HT GC-MS. Using specific chromatographic conditions and minimising sample preparation, we could separate, detect and identify a wide range of biomolecular markers covering a great variety of molecular weights and volatilities, with a minimum amount of sample, in a single run. Beeswax, spermaceti, carnauba, candellila and Japan waxes as well as pine resin derivatives, animal fats, paraffin, ozokerite and stearin, used as additives in wax works of art, were chemically investigated. In the case of low volatile compounds, transbutylation was performed. The structure of long-chain esters of spermaceti was elucidated for the first time by HT GC-MS analysis. Such a method was then carried out on 10 samples collected on a statuette of Junon by Antoine-Louis Barye (Louvre Museum, Paris, France) and on a sculpture by Aimé-Jules Dalou (Musée de la Révolution Française, Vizille, France). The analytical results obtained provide new data on the complex recipes elaborated by sculptors at the end of the 19th century.

  13. Micro-miniature gas chromatograph column disposed in silicon wafers

    DOEpatents

    Yu, Conrad M.

    2000-01-01

    A micro-miniature gas chromatograph column is fabricated by forming matching halves of a circular cross-section spiral microcapillary in two silicon wafers and then bonding the two wafers together using visual or physical alignment methods. Heating wires are deposited on the outside surfaces of each wafer in a spiral or serpentine pattern large enough in area to cover the whole microcapillary area inside the joined wafers. The visual alignment method includes etching through an alignment window in one wafer and a precision-matching alignment target in the other wafer. The two wafers are then bonded together using the window and target. The physical alignment methods include etching through vertical alignment holes in both wafers and then using pins or posts through corresponding vertical alignment holes to force precision alignment during bonding. The pins or posts may be withdrawn after curing of the bond. Once the wafers are bonded together, a solid phase of very pure silicone is injected in a solution of very pure chloroform into one end of the microcapillary. The chloroform lowers the viscosity of the silicone enough that a high pressure hypodermic needle with a thumbscrew plunger can force the solution into the whole length of the spiral microcapillary. The chloroform is then evaporated out slowly to leave the silicone behind in a deposit.

  14. Fluoroalkyl chloroformates in treating amino acids for gas chromatographic analysis.

    PubMed

    Husek, Petr; Simek, Petr; Hartvich, Petr; Zahradnícková, Helena

    2008-04-01

    Novel fluoroalkyl chloroformates with three and four carbon atoms were investigated for the immediate conversion of amino acids into hydrophobic derivatives in water-containing media. Derivatization conditions were extensively studied and optimized sample preparation protocols elaborated. More than 30 amino acids were treated with the particular reagent in isooctane by simply vortexing the reactive organic phase with a slightly basified aqueous medium containing pyridine or 3-picoline as a catalyst. Outstanding separation of nearly all components on 5% phenylmethylsilicone phase in gas chromatographic (GC) analysis with mass spectrometric (MS) or flame ionization detection (FID) required <10 min. Quantitation characteristics involving linearity in the range of 0.1-100 nmol, regression coefficients of 0.999-0.953 (histidine), MS limit of detection (LOD) reaching 0.03 pmol at proline to nearly 20 pmol at glutamic acid, plus electron impact (EI) spectra and diagnostic SIM fragment ions of the derivatives are reported. The novel method is simple, robust and rapid, enabling to treat amino acids in aqueous environment and to analyze them in <15 min. PMID:18242622

  15. Recent Advances in Water Analysis with Gas Chromatograph Mass Spectrometers

    NASA Technical Reports Server (NTRS)

    MacAskill, John A.; Tsikata, Edem

    2014-01-01

    We report on progress made in developing a water sampling system for detection and analysis of volatile organic compounds in water with a gas chromatograph mass spectrometer (GCMS). Two approaches are described herein. The first approach uses a custom water pre-concentrator for performing trap and purge of VOCs from water. The second approach uses a custom micro-volume, split-splitless injector that is compatible with air and water. These water sampling systems will enable a single GC-based instrument to analyze air and water samples for VOC content. As reduced mass, volume, and power is crucial for long-duration, manned space-exploration, these water sampling systems will demonstrate the ability of a GCMS to monitor both air and water quality of the astronaut environment, thereby reducing the amount of required instrumentation for long duration habitation. Laboratory prototypes of these water sampling systems have been constructed and tested with a quadrupole ion trap mass spectrometer as well as a thermal conductivity detector. Presented herein are details of these water sampling system with preliminary test results.

  16. The use of silica nanoparticles for gas chromatographic separation.

    PubMed

    Na, Na; Cui, Xianglan; De Beer, Thomas; Liu, Tingting; Tang, Tingting; Sajid, Muhammad; Ouyang, Jin

    2011-07-15

    A new IL-dispersed silica nanoparticles (IL-SNs) capillary column, combining properties of silica nanoparticles and ionic liquid (IL), was used for gas chromatographic separation. By dispersing silica nanoparticles in a conventional IL of 1-butyl-3-methylimidazolium hexafluorophosphate ([BuMIm][BF6]), a layer of homogeneous interconnected particulate silica networks (thickness: 0.4-0.6 μm) was formed on the inner surface of a capillary column. This coating integrates advantages of silica nanoparticles (high surface area, high dispersed behaviour) and IL (extended liquid-state temperature range, chemical stability), hence increasing interactions between stationary phase and analytes. It was demonstrated that mixtures of a wide range of organic compounds including alcohols, esters, alkanes, aromatic compounds, as well as isomers and non-polar compounds can be well separated using an IL-SNs capillary column. Comparing to traditional support coated open tubular columns, the IL-SNs capillary column displays retention behaviors of separating both polar and non-polar compounds. The much thinner coating film of IL-SNs capillary column, compared to the coating film of SNs capillary column, decreases the resistance to mass transfer, resulting a good column efficiency of 3030 theoretical plates per meter for n-butanol (which is about 5 times higher than for the SNs capillary column). Furthermore, the IL-SNs capillary column decreases the IL retention selectivity dominated by IL structures, and has a higher coating value than neat IL stationary phase. Moreover, the preparation is simple as no modification of ILs or adoption of additional reagents is needed in pretreatments. This manuscript is the first report on the use of silica nanoparticles for gas chromatography, which would expand the applicability of silica nanoparticles in analytical chemistry.

  17. Combined liquid and gas chromatographic characterisation of polyglycerol fatty acid esters.

    PubMed

    De Meulenaer, B; Van Royen, G; Vanhoutte, B; Huyghebaert, A

    2000-10-27

    In the present study a combined liquid and gas chromatographic technique is described for the analysis of polyglycerol fatty acid esters. Liquid chromatographic fractionation of samples resulted in pure standards of monoesters of di- and triglycerols and diesters of di- and triglycerols. Confirmation of their identity was achieved by LC-MS analysis. Moreover, a chromatographic identification of the mono- and diesters of cyclic diglycerol was proposed. From the isolation of pure esters and their gas chromatographic analysis, it was revealed that co-elution of several compounds occurred. Thus it was shown that prefractionation of the sample using a simplified liquid chromatographic separation, was necessary in order to characterise the esters correctly. In combination with some other chemical analyses, a complete profile of the chemical composition of polyglycerol fatty acid esters can be obtained.

  18. Miniaturized gas chromatograph-Paul ion trap system: applications to environmental monitoring

    NASA Technical Reports Server (NTRS)

    Shortt, B. J.; Darrach, M. R.; Holland, Paul M.; Chutjian, A.

    2004-01-01

    A miniature gas chromatograph (GC) and miniature Paul ion trap (PT) mass spectrometer system has been developed for identifying and quantifying chemical species present in closed environments having a complex mixture of gases.

  19. Oxygen carrier for gas chromatographic analysis of inert gases in propellants

    NASA Technical Reports Server (NTRS)

    Cannon, W. A.

    1972-01-01

    Gas chromatographic determination of small quantities of inert gases in reactive propellants is discussed. Operating conditions used for specific analyses of helium in diborane and nitrogen in oxygen difluoride are presented in tabular form.

  20. Gas chromatographic analysis of simmondsins and simmondsin ferulates in jojoba meal.

    PubMed

    Van Boven, M; Holser, R; Cokelaere, M; Flo, G; Decuypere, E

    2000-09-01

    A capillary gas chromatographic method was developed for the simultaneous determination of simmondsins and simmondsin ferulates in jojoba meal, in detoxified jojoba meal, in jojoba meal extracts, and in animal food mixtures.

  1. Gas chromatographic separation of hydrogen isotopes using metal hydrides

    SciTech Connect

    Aldridge, F.T.

    1984-05-09

    A study was made of the properties of metal hydrides which may be suitable for use in chromatographic separation of hydrogen isotopes. Sixty-five alloys were measured, with the best having a hydrogen-deuterium separation factor of 1.35 at 60/sup 0/C. Chromatographic columns using these alloys produced deuterium enrichments of up to 3.6 in a single pass, using natural abundance hydrogen as starting material. 25 references, 16 figures, 4 tables.

  2. Sensitive gas chromatographic detection of acetaldehyde and acetone using a reduction gas detector

    NASA Technical Reports Server (NTRS)

    O'Hara, Dean; Singh, Hanwant B.

    1988-01-01

    The response of a newly available mercuric oxide Reduction Gas Detector (RGD-2) to subpicomole and larger quantities of acetaldehyde and acetone is tested. The RGD-2 is found to be capable of subpicomole detection for these carbonyls and is more sensitive than an FID (Flame Ionization Detector) by an order of magnitude. Operating parameters can be further optimized to make the RGD-2 some 20-40 times more sensitive than an FID. The detector is linear over a wide range and is easily adapted to a conventional gas chromatograph (GC). Such a GC-RGD-2 system should be suitable for atmospheric carbonyl measurements in clean as well as polluted environments.

  3. The gas-chromatographic analysis system in the JET active gas handling plant

    NASA Astrophysics Data System (ADS)

    Lässer, R.; Grieveson, B.; Hemmerich, J. L.; Stagg, R.; Dowhyluk, T.; Torr, K.; Massey, R.; Chambers, P.

    1993-09-01

    A gas chromatographic system for the analysis of gas species to be collected from the JET torus and to be processed in the JET active gas handling plant during the active operation phase with deuterium and tritium plasmas was designed and built by CFFTP under contract with JET. The gas-chromatograph consists of a compression/injection stage and of two parallel, analytical stages, one for the detection of helium, hydrogen, oxygen, nitrogen, methane, carbon monoxide, and the six hydrogen molecules by means of a thermal conductivity detector (TCD) and one for the detection of carbon monoxide, methane, carbon dioxide, and higher hydrocarbons by means of a flame ionization detector (FID). A flow proportional counting detector (FPCD) is placed in series to TCD and FID for the specific analysis of tritiated gas compounds. A detailed description of the system and of its performance will be given which was evaluated using several calibrated gas mixtures including test runs with tritiated species at JET. The gas species mentioned above can be detected in the concentration range from ppm levels to 100%. The estimated error is about 20% at very low concentrations and 1% at high concentrations. The required minimum detection limit for the TCD can be achieved by the injection of large samples and the use of large filament currents. In addition, neon or helium can be chosen as carrier gas. The use of Ne increases the sensitivity for hydrogen and allows the detection of He, whereas He carrier gas gives superior TCD results for all other gases. Due to the high sensitivity of the FPCDs ppb levels of tritiated gas species can be detected.

  4. Gas-chromatographic determination of 1,3-butadiene trimers in the atmosphere

    SciTech Connect

    Drugov, Yu.S.; Murav`eva, G.V.; Shlyakhov, A.F.

    1992-02-10

    In the catalytic polymerization of 1,3-butadiene during the manufacture of SKD-1 rubber (with titanium and aluminum compounds as catalysts) the toxic oligomers (1,3-butadiene trimers) t,t,t-1, 5,9-cyclododecatriene (I), t,t,c-1, 5,9-cyclododecatriene (II), n-2,4,6,10-dodecatetraene (III), n-1,3,6,10-dodecatertraine (IV), and others end up in the atmosphere and the manufacture of cyclododecane. In the content of the oligomers in the air used for drying the rubber was determined by passing it through active carbon and desorbing the trapped substances with water vapor. However, aspects of the concentration of the microimpurities during their determination in the atmosphere were not considered. The aim of the present work was to develop a gas-chromatographic procedure for the determination of small amounts of compounds in the atmosphere. The tentative safe level amounts to 0.008 mg/m{sup 3} for (I) and 0.01 mg/m{sup 3} for (II, III). In air these oligomers are present in the form of vapor and aerosols. 7 refs., 3 figs., 4 tabs.

  5. Gas chromatographic method for measuring nitrogen dioxide and peroxyacetyl nitrate in air without compressed gas cylinders

    SciTech Connect

    Burkhardt, M.R.; Maniga, N.I.; Stedman, D.H.; Paur, R.J.

    1988-04-15

    A gas chromatographic technique that measures atmospheric concentrations of peroxyacetyl nitrate (PAN) and NO/sub 2/ has been developed that uses luminol-based chemiluminescence for detection. The carrier gas is air that has been scrubbed by passing it over FeSO/sub 4/, which eliminates the need for any compressed gas cylinders. A novel gas sampling system and time enable variable sample volumes of contaminated air to be injected. Ambient PAN and NO/sub 2/ measurements can be made every 40 s with detection limits of 0.12 ppb for PAN and 0.2 ppb for NO/sub 2/. Seven other atmospheric species, including ozone, gave no interference. Linear response was observed for NO/sub 2/ from 0.2 to 170 ppb and for PAN from 1 to 70 ppb.

  6. Instrumentation for Aerosol and Gas Speciation

    NASA Technical Reports Server (NTRS)

    Coggiola, Michael J.

    1998-01-01

    Using support from NASA Grant No. NAG 2-963, SRI International successfully completed the project, entitled, 'Instrumentation for Aerosol and Gas Speciation.' This effort (SRI Project 7383) covered the design, fabrication, testing, and deployment of a real-time aerosol speciation instrument in NASA's DC-8 aircraft during the Spring 1996 SUbsonic aircraft: Contrail and Cloud Effects Special Study (SUCCESS) mission. This final technical report describes the pertinent details of the instrument design, its abilities, its deployment during SUCCESS and the data acquired from the mission, and the post-mission calibration, data reduction, and analysis.

  7. Evolved gas analysis of secondary organic aerosols

    SciTech Connect

    Grosjean, D.; Williams, E.L. II; Grosjean, E. ); Novakov, T. )

    1994-11-01

    Secondary organic aerosols have been characterized by evolved gas analysis (EGA). Hydrocarbons selected as aerosol precursors were representative of anthropogenic emissions (cyclohexene, cyclopentene, 1-decene and 1-dodecene, n-dodecane, o-xylene, and 1,3,5-trimethylbenzene) and of biogenic emissions (the terpenes [alpha]-pinene, [beta]-pinene and d-limonene and the sesquiterpene trans-caryophyllene). Also analyzed by EGA were samples of secondary, primary (highway tunnel), and ambient (urban) aerosols before and after exposure to ozone and other photochemical oxidants. The major features of the EGA thermograms (amount of CO[sub 2] evolved as a function of temperature) are described. The usefulness and limitations of EGA data for source apportionment of atmospheric particulate carbon are briefly discussed. 28 refs., 7 figs., 4 tabs.

  8. Results from the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

    NASA Technical Reports Server (NTRS)

    Niemann, Hasso B.

    2006-01-01

    The GCMS was part of the instrument complement on the Cassini-Huygens Probe to measure in situ the chemical composition of the atmosphere during the probe descent and coupled with the Aerosol Collector Pyrolyser (ACP) experiment by serving as detector for the pyrolization products to determine the composition of the aerosol particles. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns, a chemical scrubber and a hydrocarbon enrichment cell. The GCMS gas inlet was heated to prevent condensation, and to evaporate volatiles from the surface after impact. The GCMS collected data from an altitude of 146 km to ground impact. The Probe and the GCMS survived impact and collected data for 1 hour and 9 minutes on the surface. Mass spectra were collected during descent and on the ground over a range of m/z from 2 to 141. The major constituents of the lower atmosphere were confirmed to be NP and CH4. The methane mole fraction was uniform in the stratosphere. It increased below the tropopause, at about 32 km altitude, monotonically toward the surface, reaching a plateau at about 8 km at a level near saturation. After surface impact a steep increase of the methane signal was observed, suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. The measured mole fraction of Ar-40 is 4.3 x 10(exp-5) and of Ar-36 is 2.8 x 10(exp -7). The other primordial noble gases were below mole fraction. The isotope ratios of C-12/C-13 determined from methane measurements are 82.3 and of N-14/N-15 determined from molecular nitrogen are 183. The D/H isotope ratio determined from the H2 and HD measurements is 2.3 x l0(exp -4). Carbon dioxide, ethane, acetylene and cyanogen were detected evaporating from the surface in addition to methane.

  9. New Method for Evaluating Irreversible Adsorption and Stationary Phase Bleed in Gas Chromatographic Capillary Columns

    SciTech Connect

    Wright, Bob W.; Wright, Cherylyn W.

    2012-10-26

    A novel method for the evaluation of gas chromatographic (GC) column inertness has been developed using a tandem GC approach. Typically column inertness is measured by analyte peak shape evaluation. In general, silica, glass, and metal surfaces are chemically reactive and can cause analyte adsorption, which typically is observed as chromatographic peak tailing. Adsorption processes produce broad, short chromatographic peaks that confound peak area determinations because a significant portion can reside in the noise. In addition, chromatographic surfaces and stationary phases can irreversibly adsorb certain analytes without obvious degradation of peak shape. The inertness measurements described in this work specifically determine the degree of irreversible adsorption behavior of specific target compounds at levels ranging from approximately 50 picograms to 1 nanogram on selected gas chromatographic columns. Chromatographic columns with 5% phenylmethylsiloxane, polyethylene glycol (wax), trifluoropropylsiloxane, and 78% cyanopropylsiloxane stationary phases were evaluated with a variety of phosphorus- and sulfur- containing compounds selected as test compounds due to their ease of adsorption and importance in trace analytical detection. In addition, the method was shown effective for characterizing column bleed.

  10. Residual solvent testing: a review of gas-chromatographic and alternative techniques.

    PubMed

    B'Hymer, Clayton

    2003-03-01

    The purpose of this brief review is to describe and discuss some of the current analytic procedures including gas-chromatographic and alternative techniques for residual solvent testing. Residual solvents, or organic volatile impurities, are a potential toxic risk for pharmaceutic products and have been a concern of manufacturers for many years. Residual solvents have had official limits in the United States as set in USP XXV and by the FDA in 1997 and have been monitored by most pharmaceutical manufacturers extensively for more than two decades in both bulk and finished products. The chief method of analysis for residual solvents is gas chromatography, which is generally considered the preferred methodology. Sample introduction techniques include both static and dynamic headspace analysis, solid-phase microextraction, and direct injection of solution containing bulk drug substance or drug product into the gas chromatograph. Also, some alternative methodologies for residual solvent testing are discussed in this review. In conclusion, gas chromatograph-based procedures will continue to dominate residual solvent testing because of its specificity for identification of the solvent, but the use of alternative sample introduction techniques into a gas chromatograph will continue to expand in the near future.

  11. Gas-chromatographic characterization of physicochemical properties of astatine compounds

    SciTech Connect

    Norseev, Yu.V.

    1995-07-01

    The organoastatine compounds obtained were identified by gas-liquid chromatography on a specially designed gas radiochromatograph with detection of eluted compounds both by their radioactivity and by thermal conductivity. Gas-liquid chromatography is the most efficient method for separation and identification of volatile organoastatine compounds.

  12. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, EXPLOSIVES DETECTION TECHNOLOGY, SRI INSTRUMENTS, MODEL 8610C, GAS CHROMATOGRAPH/THERMIONIC IONIZATION DETECTION

    EPA Science Inventory

    The SRI Model 86 1 OC gas chromatograph (GC) is a transportable instrument that can provide on-site analysis of soils for explosives. Coupling this transportable gas chromatograph with a thermionic ionization detector (TID) allows for the determination of explosives in soil matri...

  13. Characterization of Gas Chromatographic Liquid Phases Using McReynolds Constants. An Experiment for Instrumental Analysis Laboratory.

    ERIC Educational Resources Information Center

    Erskine, Steven R.; And Others

    1986-01-01

    Describes a laboratory experiment that is designed to aid in the understanding of the fundamental process involved in gas chromatographic separations. Introduces the Kovats retention index system for use by chemistry students to establish criteria for the optimal selection of gas chromatographic stationary phases. (TW)

  14. Acrylamide analysis in food by liquid chromatographic and gas chromatographic methods.

    PubMed

    Elbashir, Abdalla A; Omar, Mei M Ali; Ibrahim, Wan Aini Wan; Schmitz, Oliver J; Aboul-Enein, Hassan Y

    2014-01-01

    Acrylamide (AA) is a compound classified as carcinogenic to humans by the International Agency for Research on Cancer. It was first discovered to be present in certain heated processed food by the Swedish National Food Administration (SNFA) and University of Stockholm in early 2002. The major pathway for AA formation in food is the Maillard reaction between reducing sugar and the amino acid asparagine at high temperature. Since the discovery of AA's presence in food, many analytical methods have been developed for determination of AA contents in different food matrices. Also, several studies have been conducted to develop extraction procedures for AA from difficult food matrices. AA is a small, highly polar molecule, which makes its extraction and analysis challenging. Many articles and reviews have been published dealing with AA in food. The aim of the review is to discuss AA formation in food, the factors affecting AA formation and removal, AA exposure assessment, AA extraction and cleanup from food samples, and analytical methods used in AA determination, such as high-performance liquid chromatography (HPLC) and gas chromatography (GC). Special attention is given to sample extraction and cleanup procedures and analytical techniques used for AA determination.

  15. SAGE II inversion algorithm. [Stratospheric Aerosol and Gas Experiment

    NASA Technical Reports Server (NTRS)

    Chu, W. P.; Mccormick, M. P.; Lenoble, J.; Brogniez, C.; Pruvost, P.

    1989-01-01

    The operational Stratospheric Aerosol and Gas Experiment II multichannel data inversion algorithm is described. Aerosol and ozone retrievals obtained with the algorithm are discussed. The algorithm is compared to an independently developed algorithm (Lenoble, 1989), showing that the inverted aerosol and ozone profiles from the two algorithms are similar within their respective uncertainties.

  16. 40 CFR 1065.267 - Gas chromatograph with a flame ionization detector.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Gas chromatograph with a flame ionization detector. 1065.267 Section 1065.267 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Hydrocarbon...

  17. 40 CFR 1065.267 - Gas chromatograph with a flame ionization detector.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Gas chromatograph with a flame ionization detector. 1065.267 Section 1065.267 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Hydrocarbon...

  18. 40 CFR 1065.267 - Gas chromatograph with a flame ionization detector.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Gas chromatograph with a flame ionization detector. 1065.267 Section 1065.267 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Hydrocarbon...

  19. NEAR-CONTINUOUS MEASUREMENT OF HYDROGEN SULFIDE AND CARBONYL SULFIDE BY AN AUTOMATIC GAS CHROMATOGRAPH

    EPA Science Inventory

    An automatic gas chromatograph with a flame photometric detector that samples and analyzes hydrogen sulfide and carbonyl sulfide at 30-s intervals is described. Temperature programming was used to elute trace amounts of carbon disulfide present in each injection from a Supelpak-S...

  20. Simple gas chromatographic system for analysis of microbial respiratory gases

    NASA Technical Reports Server (NTRS)

    Carle, G. C.

    1972-01-01

    Dual column ambient temperature system, consisting of pair of capillary columns, microbead thermistor detector and micro gas-sampling valve, is used in remote life-detection equipment for space experiments. Performance outweighs advantage gained by utilizing single-column systems to reduce weight, conserve carrier gas and operate at lower power levels.

  1. Sensitive gas chromatographic--mass spectrometric screening of acetylated benzodiazepines.

    PubMed

    Borrey, D; Meyer, E; Lambert, W; Van Calenbergh, S; Van Peteghem, C; De Leenheer, A P

    2001-02-23

    GC-MS screening conditions were developed for 15 low-dosed benzodiazepines, covering alprazolam, flunitrazepam, flurazepam, ketazolam, lorazepam and triazolam, and the corresponding metabolites alpha-hydroxyalprazolam, 4-hydroxyalprazolam; 7-aminoflunitrazepam, desmethylflunitrazepam, 7-aminodesmethylflunitrazepam; hydroxyethylflurazepam, N-desalkylflurazepam; oxazepam and alpha-hydroxytriazolam, respectively. Benzodiazepines are analyzed on a polydimethylsiloxane column in both the scan and the multiple ion monitoring modes using on-column injection to attain maximal sensitivity. The reactive compounds are acetylated with pyridine and acetic anhydride for 20 min. The derivatives are stable for at least 4 days. The relative standard deviation observed with standard compounds at the low nanogram-level ranged from 1.13 to 4.87% within-day and from 1.12 to 4.94% between-day. Unequivocal identification potential, high chromatographic resolution and sensitivity are combined with minimal thermal degradation. The presented screening conditions provide the basis for a unique routine screening method for low-dosed benzodiazepines with a broad polarity range.

  2. Derivatization in gas chromatographic determination of phenol and aniline traces in aqueous media

    NASA Astrophysics Data System (ADS)

    Gruzdev, I. V.; Zenkevich, I. G.; Kondratenok, B. M.

    2015-06-01

    Substituted anilines and phenols are the most common hydrophilic organic environmental toxicants. The principles of gas chromatographic determination of trace amounts of these compounds in aqueous media at concentrations <=0.1 μg litre-1 based on synthesis of their derivatives (derivatization) directly in the aqueous phase are considered. Conversion of relatively hydrophilic analytes into more hydrophobic derivatives makes it possible to achieve such low detection limits and optimize the protocols of extractive preconcentration and selective chromatographic detection. Among the known reactions, this condition is best met by electrophilic halogenation of compounds at the aromatic moiety. The bibliography includes 177 references.

  3. Gas chromatographic analysis of synthetic glycidol esters, mono-, di- and triglycerides.

    PubMed

    Engbersen, J A; van Stijn, F

    1976-03-01

    The gas chromatographic analysis of glycidol esters and mono-, di-,and triglycerides of palmitic-, stearic-, and oleic acid mixtures is described. The composition of the products was determined by gas chromatography on OV-17 after trimethylsilylation. Base-line separations between 1- and 2-monoglycerides and between 1,2- and 1,3-diglycerides were obtained. Isomerisation of the trimethylsilyl ethers of monoglycerides was not observed, contrary to published work.

  4. Development of and fabrication of high resolution gas chromatographic capillary columns

    NASA Technical Reports Server (NTRS)

    Zlatkis, A.

    1982-01-01

    Gas chromatographic columns which are used in the trace gas analyzer (TGA) for the space shuttle are coated with a polyoxyethylene lauryl ether. This stationary phase is of medium polarity and has a temperature limit of 160 C. A polymer for this application which has an improved thermal stability is investigated. The use of fused silica capillary columns with specially bonded phases as well as an introduction system (on column) was also studied.

  5. A global aerosol classification algorithm incorporating multiple satellite data sets of aerosol and trace gas abundances

    NASA Astrophysics Data System (ADS)

    Penning de Vries, M. J. M.; Beirle, S.; Hörmann, C.; Kaiser, J. W.; Stammes, P.; Tilstra, L. G.; Tuinder, O. N. E.; Wagner, T.

    2015-09-01

    Detecting the optical properties of aerosols using passive satellite-borne measurements alone is a difficult task due to the broadband effect of aerosols on the measured spectra and the influences of surface and cloud reflection. We present another approach to determine aerosol type, namely by studying the relationship of aerosol optical depth (AOD) with trace gas abundance, aerosol absorption, and mean aerosol size. Our new Global Aerosol Classification Algorithm, GACA, examines relationships between aerosol properties (AOD and extinction Ångström exponent from the Moderate Resolution Imaging Spectroradiometer (MODIS), UV Aerosol Index from the second Global Ozone Monitoring Experiment, GOME-2) and trace gas column densities (NO2, HCHO, SO2 from GOME-2, and CO from MOPITT, the Measurements of Pollution in the Troposphere instrument) on a monthly mean basis. First, aerosol types are separated based on size (Ångström exponent) and absorption (UV Aerosol Index), then the dominating sources are identified based on mean trace gas columns and their correlation with AOD. In this way, global maps of dominant aerosol type and main source type are constructed for each season and compared with maps of aerosol composition from the global MACC (Monitoring Atmospheric Composition and Climate) model. Although GACA cannot correctly characterize transported or mixed aerosols, GACA and MACC show good agreement regarding the global seasonal cycle, particularly for urban/industrial aerosols. The seasonal cycles of both aerosol type and source are also studied in more detail for selected 5° × 5° regions. Again, good agreement between GACA and MACC is found for all regions, but some systematic differences become apparent: the variability of aerosol composition (yearly and/or seasonal) is often not well captured by MACC, the amount of mineral dust outside of the dust belt appears to be overestimated, and the abundance of secondary organic aerosols is underestimated in comparison

  6. Development of gas chromatographic system for dissolved organic carbon analysis in seawater. Annual progress report

    SciTech Connect

    Chipman, D.W.; Takahashi, T.

    1992-12-01

    During the first six months of this two-year grant, we have completed the construction of the analytical portion of a prototype gas chromatograph-based system for the analysis of dissolved organic carbon in seawater. We also have begun testing the procedures to be used to cryogenically concentrate and transfer carbon dioxide from the oxidizing atmosphere of the high-temperature furnace into the reducing hydrogen carrier gas of the gas chromatograph. During the second half of the first year, we will construct the high-temperature catalytic oxidation furnace and test the entire system on laboratory-prepared aqueous solutions of various organic compounds. Also during this period, we will take part in an initial scoping study within the Cape Hatteras field area on board the R/V Gyre. This study will involve both the collection of samples of seawater for organic and inorganic carbon analysis and the measurement of surface-water pCO{sub 2}.

  7. Development of gas chromatographic system for dissolved organic carbon analysis in seawater

    SciTech Connect

    Chipman, D.W.; Takahashi, T.

    1992-12-01

    During the first six months of this two-year grant, we have completed the construction of the analytical portion of a prototype gas chromatograph-based system for the analysis of dissolved organic carbon in seawater. We also have begun testing the procedures to be used to cryogenically concentrate and transfer carbon dioxide from the oxidizing atmosphere of the high-temperature furnace into the reducing hydrogen carrier gas of the gas chromatograph. During the second half of the first year, we will construct the high-temperature catalytic oxidation furnace and test the entire system on laboratory-prepared aqueous solutions of various organic compounds. Also during this period, we will take part in an initial scoping study within the Cape Hatteras field area on board the R/V Gyre. This study will involve both the collection of samples of seawater for organic and inorganic carbon analysis and the measurement of surface-water pCO[sub 2].

  8. The Construction of a Simple Pyrolysis Gas Chromatograph.

    ERIC Educational Resources Information Center

    Hedrick, Jack L.

    1982-01-01

    Describes a simple and inexpensive pyrolysis gas chromatography (PGC) system constructed from items available in undergraduate institutions. The system is limited, accepting only liquid samples and pyrolyzing "on the fly" rather than statically and not allowing for reductive pyrolysis. Applications, experiments, and typical results are included.…

  9. Rapid gas-chromatographic assay of bupivacaine in plasma.

    PubMed

    Le Normand, Y; Athouel, A; Blanloeil, Y; De Villepoix, C; Melchior, J C; Kergueris, M F; Bourin, M; Larousse, C

    1987-01-01

    A method for estimating bupivacaine concentration in human plasma by capillary gas-chromatography using solid injection and nitrogen-specific detection is described. Etidocaine, another anilidetype local anesthetic was used as internal standard and added to the sample before single-step extraction with diethylether. This method demonstrates high sensitivity (6 ng/ml plasma) and combines selectivity, rapidity, and simplicity. Results of this procedure correlate well with those obtained by an HPLC method.

  10. Interactions of Gas-Phase Nitric/Nitrous Acids and Primary Organic Aerosol in the Atmosphere of Houston, TX

    NASA Astrophysics Data System (ADS)

    Ziemba, L. D.; Griffin, R. J.; Dibb, J. E.; Anderson, C. H.; Whitlow, S. I.; Lefer, B. L.; Flynn, J.; Rappenglück, B.

    2007-12-01

    Concentrations of aerosol and gas-phase pollutants were measured on the roof of an 18-story building during the Texas Air Quality Study II Radical and Aerosol Measurement Project (TRAMP) from August 15 through September 28, 2006. Aerosol measurements included size-resolved, non-refractory mass concentrations of ammonium, nitrate, sulfate, chloride, and organic aerosol in submicron particles using an Aerodyne quadrupole aerosol mass spectrometer (Q-AMS). Particulate water-soluble organic carbon (PWSOC) was quantified using a mist chamber/total organic carbon analysis system. Concentration data for gas-phase pollutants included those for nitric acid (HNO3), nitrous acid (HONO), and hydrochloric acid (HCl) collected using a mist chamber/ion chromatographic technique, oxides of nitrogen (NOx) collected using a chemiluminescent method, and carbon monoxide (CO) collected using an infrared gas correlation wheel instrument. Coincident increases in nitrate and organic aerosol mass concentrations were observed on many occasions throughout the measurement campaign, most frequently during the morning rush hour. Based on the lack of organic aerosol processing (defined by the ratio of m/z = 44/57 in the Q-AMS spectra), strong correlation with NOx and CO, and a lack of significant increase in PWSOC concentration, the spikes in organic aerosol were likely associated with primary organic aerosol (POA). During these events, gas-phase HNO3 concentration decreases were observed simultaneously with increases in gas-phase HONO concentrations. These data likely indicate uptake of HNO3 and subsequent heterogeneous conversion to HONO involving POA. Preliminary calculations show that HNO3 partitioning could account for the majority of the observed HONO and aerosol nitrate concentrations during these events. Q-AMS chloride and HCl data also indicate uptake of chloride by particles during these events. This phenomenon was also observed during the night, but these nocturnal events were less

  11. Gas chromatograph monitors for VCM, automatically alerts emergency team

    SciTech Connect

    Rogers, J.C.; Ormond, D.L.

    1986-09-01

    Delaware City, located on the Delaware River with a metropolitan population of around 100,000, has played host to numerous companies in the CPI. The community has witnessed the expansion to a current level of eleven plants and a large oil refinery. Identified by the DNREC as possibly the most serious of recent problems was the potential for release of vinyl chloride monomer (VCM) gas. VCM is a recognized carcinogen and is considered a hazardous waste and a priority pollutant by the EPA. A Citizens' Advisory Committee recommended that a permanent air monitor for detection of VCM be strategically located in Delaware City. It needed to be capable of detecting VCM at 50 ppb and utilize a suitable alarm procedure to alert the public. The committee also recommended the use of a mobile monitor equipped to track a VCM release which could by-pass the Delaware City monitor and threaten nearby residents during certain wind conditions. A gas chromatography with photoionization detector (PID) was selected based on the required specifications and on commercial availability. The Delaware City firehouse was selected as the most publicly acceptable location with sufficient security and unobstructed sampling at an adequate height. The air in Delaware City has been monitored continuously since December 9, 1985. As of April, 1986, the instrument has completed, 30,000 combined sample and calibration runs. No unusual problems have been encountered with maintenance or with anomalous data. It has required only routine service, surpassing the manufacturer's guarantees for parts and service.

  12. Gas-chromatographic retention indexes of organic sulfur (II) compounds

    SciTech Connect

    Garbuzov, V.G.; Aerov, A.F.; Golovnya, R.V.; Misharina, T.A.

    1985-10-01

    Despite the large number of papers on the gas chromatographyof sulfur-containing compounds, according to the authors no systematic study has been carried out of their behavior, showing the dependences of the sorptional characteristics on the structure of the molecule and on the polarity of the stationary phase. The present article systematizes the results of many years of work on the determination on four columns with different polarity of retention indexes of sulfurcontaining compounds: mercaptans, dimercaptans, di-n-alkyl sulfides, n-alkyl isoalkyl sulfides, diisoalkyl sulfides, unsaturated sulfides, di-n-alkyl disulfides, and many others, in all more than 400 compounds. The data obtained and the regularities in their change, depending on the structure and polarity of the stationary phases, were successfully used to identify sulfur-containing compounds in the study of the odor composition of salmon flesh, boiled beef, boiled-corned pork and an aromatizer with a meat aroma.

  13. Inverse gas chromatography and other chromatographic techniques in the examination of engine oils.

    PubMed

    Fall, Jacek; Voelkel, Adam

    2002-09-01

    The emerging market of engine oils consists of a number of products from different viscosity and quality classes. Determination of the base oil used in manufacturing of the final product (engine oil) as well as estimation of mutual miscibility of oils and their solubility could be crucial problems. Inverse gas chromatography and other chromatographic techniques are presented as an interesting and fruitful extension of normalised standard analytical methods used in the oil industry. PMID:12385390

  14. Portable gas chromatograph mass spectrometer for on-site chemical analyses

    DOEpatents

    Haas, Jeffrey S.; Bushman, John F.; Howard, Douglas E.; Wong, James L.; Eckels, Joel D.

    2002-01-01

    A portable, lightweight (approximately 25 kg) gas chromatograph mass spectrometer, including the entire vacuum system, can perform qualitative and quantitative analyses of all sample types in the field. The GC/MS has a conveniently configured layout of components for ease of serviceability and maintenance. The GC/MS system can be transported under operating or near-operating conditions (i.e., under vacuum and at elevated temperature) to reduce the downtime before samples can be analyzed on-site.

  15. Minimizing thermal degradation in gas chromatographic quantitation of pentaerythritol tetranitrate.

    PubMed

    Lubrano, Adam L; Field, Christopher R; Newsome, G Asher; Rogers, Duane A; Giordano, Braden C; Johnson, Kevin J

    2015-05-15

    An analytical method for establishing calibration curves for the quantitation of pentaerythriol tetranitrate (PETN) from sorbent-filled thermal desorption tubes by gas chromatography with electron capture detection (TDS-GC-ECD) was developed. As PETN has been demonstrated to thermally degrade under typical GC instrument conditions, peaks corresponding to both PETN degradants and molecular PETN are observed. The retention time corresponding to intact PETN was verified by high-resolution mass spectrometry with a flowing atmospheric pressure afterglow (FAPA) ionization source, which enabled soft ionization of intact PETN eluting the GC and subsequent accurate-mass identification. The GC separation parameters were transferred to a conventional GC-ECD instrument where analytical method-induced PETN degradation was further characterized and minimized. A method calibration curve was established by direct liquid deposition of PETN standard solutions onto the glass frit at the head of sorbent-filled thermal desorption tubes. Two local, linear relationships between detector response and PETN concentration were observed, with a total dynamic range of 0.25-25ng. PMID:25841610

  16. Gas chromatographic column for the storage of sample profiles

    NASA Technical Reports Server (NTRS)

    Dimandja, J. M.; Valentin, J. R.; Phillips, J. B.

    1994-01-01

    The concept of a sample retention column that preserves the true time profile of an analyte of interest is studied. This storage system allows for the detection to be done at convenient times, as opposed to the nearly continuous monitoring that is required by other systems to preserve a sample time profile. The sample storage column is essentially a gas chromatography column, although its use is not the separation of sample components. The functions of the storage column are the selective isolation of the component of interest from the rest of the components present in the sample and the storage of this component as a function of time. Using octane as a test substance, the sample storage system was optimized with respect to such parameters as storage and readout temperature, flow rate through the storage column, column efficiency and storage time. A 3-h sample profile was collected and stored at 30 degrees C for 20 h. The profile was then retrieved, essentially intact, in 5 min at 130 degrees C.

  17. Gas chromatographic determination of pesticide residues in white mustard.

    PubMed

    Słowik-Borowiec, Magdalena; Szpyrka, Ewa; Walorczyk, Stanisław

    2015-04-15

    A new analytical method employing gas chromatography coupled to electron capture and nitrogen phosphorus detection (GC-ECD/NPD) has been developed and validated for the screening and quantification of 51 pesticides in a matrix of high chlorophyll content - white mustard (Sinapis alba L.). For preparation of the sample extract, the citrate buffered QuEChERS procedure was followed. However certain changes were made to adapt the method to our needs and available laboratory resources. The sample size was reduced to 5 g, 10 mL water was added and exchange of solvent before GC analysis was done. The samples spiked with the target pesticides at the concentration level 0.01 mg/kg and a higher level (depending on the compound) yielded average recoveries in the range of 70-120% with relative standard deviations (RSDs) 0-19% except for HCB, S-metolachlor and teflubenzuron, and displayed very good linearity (R(2)>0.99) for nearly all the analytes. Limit of quantification was 0.01 mg/kg for the majority of the analytes. The expanded measurement uncertainties were estimated employing a "top-down" empirical model as being between 6% and 32% and yielding an average value of 18% (coverage factor k=2, confidence level 95%). PMID:25466117

  18. A Gas Chromatograph/Mass Spectrometer System for UltraLow-Emission Combustor Exhaust Studies

    NASA Technical Reports Server (NTRS)

    Brabbs, Theodore A.; Wey, Chowen Chou

    1996-01-01

    A gas chromatograph (GC)/mass spectrometer (MS) system that allows the speciation of unburnt hydrocarbons in the combustor exhaust has been developed at the NASA Lewis Research Center. Combustion gas samples are withdrawn through a water-cooled sampling probe which, when not in use, is protected from contamination by a high-pressure nitrogen purge. The sample line and its connecting lines, filters, and valves are all ultraclean and are heated to avoid condensation. The system has resolution to the parts-per-billion (ppb) level.

  19. Organic compounds present in the natural Amazonian aerosol: Characterization by gas chromatography-mass spectrometry

    NASA Astrophysics Data System (ADS)

    Graham, Bim; Guyon, Pascal; Taylor, Philip E.; Artaxo, Paulo; Maenhaut, Willy; Glovsky, M. Michael; Flagan, Richard C.; Andreae, Meinrat O.

    2003-12-01

    As part of the Large-Scale Biosphere-Atmosphere Experiment in Amazonia (LBA)-Cooperative LBA Airborne Regional Experiment (CLAIRE) 2001 campaign in July 2001, separate day and nighttime aerosol samples were collected at a ground-based site in Amazonia, Brazil, in order to examine the composition and temporal variability of the natural "background" aerosol. We used a high-volume sampler to separate the aerosol into fine (aerodynamic diameter, AD < 2.5 μm) and coarse (AD > 2.5 μm) size fractions and quantified a range of organic compounds in methanolic extracts of the samples by a gas chromatographic-mass spectrometric technique. The carbon fraction of the compounds could account for an average of 7% of the organic carbon (OC) in both the fine and coarse aerosol fractions. We observed the highest concentrations of sugars, sugar alcohols, and fatty acids in the coarse aerosol samples, which suggests that these compounds are associated with primary biological aerosol particles (PBAP) observed in the forest atmosphere. Of these, trehalose, mannitol, arabitol, and the fatty acids were found to be more prevalent at night, coinciding with a nocturnal increase in PBAP in the 2-10 μm size range (predominantly yeasts and other small fungal spores). In contrast, glucose, fructose, and sucrose showed persistently higher daytime concentrations, coinciding with a daytime increase in large fungal spores, fern spores, pollen grains, and, to a lesser extent, plant fragments (generally >20 μm in diameter), probably driven by lowered relative humidity and enhanced wind speeds/convective activity during the day. For the fine aerosol samples a series of dicarboxylic and hydroxyacids were detected with persistently higher daytime concentrations, suggesting that photochemical production of a secondary organic aerosol from biogenic volatile organic compounds may have made a significant contribution to the fine aerosol. Anhydrosugars (levoglucosan, mannosan, galactosan), which are

  20. Application of gas chromatographic method in simultaneous measurements of helium, argon and neon concentration in groundwaters

    NASA Astrophysics Data System (ADS)

    Najman, J.; Bielewski, J.; Sliwka, I.

    2012-04-01

    Helium concentration in groundwater is a fine indicator in water dating in a range from a hundred to tens of thousands of years. Gas chromatography (GC) measurements of helium can be used as an alternative to mass spectrometry (MS) determinations of 4He for groundwater dating [1]. Argon and neon concentrations mainly serve for determining the temperature of recharge and the air excess which is needed to correct measured values of helium concentration [2] . A chromatographic measurement system of helium, argon and neon concentration in groundwater is presented [3]. Water samples are taken from groundwater with a precise procedure without contamination with air in a special stainless steel vessels of volume equal to 2900 cm3. Helium is extracted from water samples using the head-space method. After enrichment by cryotrap method helium is analyzed in the gas chromatograph equipped with the thermal conductivity detector (TCD) with detection limit of about 2.8 ng He. The helium limit of detection of presented method is 1,2·10-8 cm3STP/gH2O [4]. We are currently working on adapting the method of cryogenic enrichment of helium concentration for simultaneous measurements of the concentration of helium, argon and neon using single sample of groundwater. Neon will be measured with the thermal conductivity detector and capillary column filled with molecular sieve 5A. Argon will be analyzed also with the thermal conductivity detector and packed column filled with molecular sieve 5A. This work was supported by grant No. N N525 3488 38 from the polish National Science Centre. [1] A. Zuber, W. Ciężkowski, K. Różański (red.), Tracer methods in hydrogeological studies - a methodological guide. Wroclaw University of Technology Publishing House, Wroclaw, 2007 (in polish). [2] P. Mochalski, Chromatographic method for the determination of Ar, Ne and N2 in water, Ph.D. thesis, Institute of Nuclear Physics Polish Academy of Sciences in Krakow, 2003 (in polish). [3] A. Żurek, P

  1. Determinations of gas-liquid partition coefficients using capillary chromatographic columns. Alkanols in squalane.

    PubMed

    Tascon, Marcos; Romero, Lílian M; Acquaviva, Agustín; Keunchkarian, Sonia; Castells, Cecilia

    2013-06-14

    This study focused on an investigation into the experimental quantities inherent in the determination of partition coefficients from gas-liquid chromatographic measurements through the use of capillary columns. We prepared several squalane - (2,6,10,15,19,23-hexamethyltetracosane) - containing columns with very precisely known phase ratios and determined solute retention and hold-up times at 30, 40, 50 and 60°C. We calculated infinite dilution partition coefficients from the slopes of the linear regression of retention factors as a function of the reciprocal of the phase ratio by means of fundamental chromatographic equations. In order to minimize gas-solid and liquid-solid interface contributions to retention, the surface of the capillary inner wall was pretreated to guarantee a uniform coat of stationary phase. The validity of the proposed approach was first tested by estimating the partition coefficients of n-alkanes between n-pentane and n-nonane, for which compounds data from the literature were available. Then partition coefficients of sixteen aliphatic alcohols in squalane were determined at those four temperatures. We deliberately chose these highly challenging systems: alcohols in the reference paraffinic stationary phase. These solutes exhibited adsorption in the gas-liquid interface that contributed to retention. The corresponding adsorption constant values were estimated. We fully discuss here the uncertainties associated with each experimental measurement and how these fundamental determinations can be performed precisely by circumventing the main drawbacks. The proposed strategy is reliable and much simpler than the classical chromatographic method employing packed columns.

  2. Experimental studies of gas-aerosol reactions

    NASA Astrophysics Data System (ADS)

    Gupta, Anand

    1991-05-01

    The aqueous phase oxidation of SO2 by H2O2 is believed to the principle mechanism for atmospheric sulfate formation in cloud droplets. However, no studies in noncloud aerosol systems have been reported. The objective is to quantify the importance of the noncloud liquid phase reactions of SO2 by H2O2 in the atmosphere. Growth rates of submicron droplets exposed to SO2 and H2O2 were measured using the tandem differential mobility analyzer (TDMA) technique (Rader and McMurry, 1986). The technique uses differential mobility analyzers (DMA's) to generate monodisperse particles and to measure particle size after the reaction. To facilitate submicron monodisperse droplet production with the DMA, a low-ion-concentration charter capable of generating singly charged particles up to 1.0 microns was developed and experimentally evaluated. The experiments were performed using dry and deliquesced (NH4)2SO4 particles with SO2 and H2O2 concentrations from 0-860 ppb and 0-150 ppb, respectively. No growth was observed for dry particles. For droplets greater than or equal to 0.3 microns, the fractional diameter growth was independent of particle size and for droplets less than or equal to 0.2 microns, it decreased as particle size decreased. The observed decrease is due to NH3 evaporation. As ammonia evaporates, droplet pH decreases causing the oxidation rate to decrease, leading to a lower growth rate. To predict the size-dependent growth rates, a theoretical model was developed using solution thermodynamics, gas/particle equilibrium, and chemical kinetics. The experimental and theoretical results are in reasonable agreement. For dry (NH4)2SO4 particles exposed to SO2, H2O2, NH3, and H2O vapor, surface reaction-controlled growth was observed. Particle growth was very sensitive to particle composition. No growth was observed for Polystyrene latex particles, whereas (NH4)2SO4 particles doped with catalysts (Fe(2+), Fe(3+), Mn(2+) and Cu(2+)) in a molar ratio of 1:500 grew slower than

  3. Capillary gas chromatographic determination of dimethachlon residues in fresh tobacco leaves and cut-tobacco*

    PubMed Central

    Liu, Hong-cheng; Li, Qi-wan; Tang, Li-bin

    2007-01-01

    Simple procedures for extraction and chromatographic determination of dimethachlon residues in fresh tobacco leaves and cut-tobacco are described. The determination was carried out by capillary gas chromatography (GC) with electron capture detection (ECD) and confirmed by GC-MS. The mean recoveries and relative standard deviation (RSD) were 93.2%~112.9% and 3.5%~6.7%, respectively at levels ranging from 0.01 to 0.1 mg/kg. The limit of determination was 0.001 mg/kg. Tobacco samples in routine check were successfully analyzed using the proposed method. PMID:17444603

  4. Influence of solvents and gas chromatographic injector conditions on the detectability of nitroaromatic compounds.

    PubMed

    Emmrich, M; Lahrz, T; Spyra, W

    2001-05-18

    We investigated the influence of four common solvents and of several liner packings of a split/splitless injector on the gas chromatographic behavior of trinitrotoluenes and related nitroaromatic compounds. The highest peaks are observed using toluene in combination with an empty liner or with a prepacked CarboFrit liner. In particular, the peaks of trinitrotoluene isomers and 1,3,5-trinitrobenzene significantly decreased or even totally disappeared when using quartz wool or glass wool, even when treated with dimethylchlorosilane. Similiar peak reductions are obtained with methanol or acetonitrile. Effects of decreasing peak are accompanied by the formation of two additional products when using methanol.

  5. Gas chromatographic analysis of organic marker compounds in fine particulate matter using solid-phase microextraction.

    PubMed

    Lin, Lin; Lee, Milton L; Eatough, Delbert J

    2007-01-01

    A gas chromatographic method that uses solid-phase microextraction for analysis of organic marker compounds in fine particulate matter (PM2.5) is reported. The target marker compounds were selected for specificity toward emission from wood smoke, diesel or gasoline combustion, or meat cooking. Temperature-programmed volatilization analysis was used to characterize the thermal stabilities and volatile properties of the compounds of interest. The compounds were thermally evaporated from a quartz filter, sorbed to a solid phase microextraction (SPME) fiber, and thermally desorbed at 280 degrees C in a gas chromatograph injection port connected via a DB 1701 capillary separating column. Various experimental parameters (fiber type, time, and temperature of sorption) were optimized. It was found that high extraction yield could be achieved using a polyacrylate fiber for polar substances, such as levoglucosan, and a 7-microm polydimethylsiloxane (PDMS)-coated fiber for nonpolar compounds, such as hopanes and polyaromatic hydrocarbon. A compromise was made by selecting a carboxen/PDMS fiber, which can simultaneously extract all of the analytes of interest with moderate-to-high efficiency at 180 degrees C within a 30-min accumulation period. The optimized method was applied to the determination of levoglucosan in pine wood combustion emissions. The simplicity, rapidity, and selectivity of sample collection with a polymer-coated SPME coupled to capillary gas chromatography (GC) made this method potentially useful for atmospheric chemistry studies.

  6. Gas chromatographic organic acid profiling analysis of brandies and whiskeys for pattern recognition analysis.

    PubMed

    Park, Y J; Kim, K R; Kim, J H

    1999-06-01

    An efficient gas chromatographic profiling and pattern recognition method is described for brandy and whiskey samples according to their organic acid contents. It involves solid-phase extraction of organic acids using Chromosorb P with subsequent conversion to stable tert-butyldimethylsilyl derivatives for the direct analysis by capillary column gas chromatography and gas chromatography-mass spectrometry. A total of 12 organic acids were reproducibly identified in liquor samples (1 mL). When the GC profiles were simplified to their retention index spectra, characteristic patterns were obtained for each liquor sample as well as for each group average. Stepwise discriminant analysis provided star symbols characteristic for each liquor sample and group average. As expected, canonical discriminant analysis correctly classified 23 liquor samples studied into two groups of either brandy or whiskey.

  7. Screening of ground water samples for volatile organic compounds using a portable gas chromatograph

    USGS Publications Warehouse

    Buchmiller, R.C.

    1989-01-01

    A portable gas chromatograph was used to screen 32 ground water samples for volatile organic compounds. Seven screened samples were positive; four of the seven samples had volatile organic substances identified by second-column confirmation. Four of the seven positive, screened samples also tested positive in laboratory analyses of duplicate samples. No volatile organic compounds were detected in laboratory analyses of samples that headspace screening indicated to be negative. Samples that contained volatile organic compounds, as identified by laboratory analysis, and that contained a volatile organic compound present in a standard of selected compounds were correctly identified by using the portable gas chromatography. Comparisons of screened-sample data with laboratory data indicate the ability to detect selected volatile organic compounds at concentrations of about 1 microgram per liter in the headspace of water samples by use of a portable gas chromatography. -Author

  8. Gas chromatographic organic acid profiling analysis of brandies and whiskeys for pattern recognition analysis.

    PubMed

    Park, Y J; Kim, K R; Kim, J H

    1999-06-01

    An efficient gas chromatographic profiling and pattern recognition method is described for brandy and whiskey samples according to their organic acid contents. It involves solid-phase extraction of organic acids using Chromosorb P with subsequent conversion to stable tert-butyldimethylsilyl derivatives for the direct analysis by capillary column gas chromatography and gas chromatography-mass spectrometry. A total of 12 organic acids were reproducibly identified in liquor samples (1 mL). When the GC profiles were simplified to their retention index spectra, characteristic patterns were obtained for each liquor sample as well as for each group average. Stepwise discriminant analysis provided star symbols characteristic for each liquor sample and group average. As expected, canonical discriminant analysis correctly classified 23 liquor samples studied into two groups of either brandy or whiskey. PMID:10794629

  9. Discrimination of cloud and aerosol in the Stratospheric Aerosol and Gas Experiment III occultation data.

    PubMed

    Kent, G S; Wang, P H; Skeens, K M

    1997-11-20

    The Stratospheric Aerosol and Gas Experiment (SAGE) III, scheduled for a first launch in mid-1998, will be making measurements of the extinction that is due to aerosols and gases at many wavelengths between 385 and 1550 nm. In the troposphere and wintertime polar stratosphere, extinction will also occur because of the presence of cloud along the optical path from the Sun to the satellite instrument. We describe a method for separating the effects of aerosol and cloud using the extinction at 525, 1020, and 1550 nm and present the results of simulation studies. These studies show that the new method will work well under background nonvolcanic aerosol conditions in the upper troposphere and lower stratosphere. Under conditions of severe volcanic contamination, the error rate for the separation of aerosol and cloud may rise as high as 30%.

  10. Application of Gas Chromatographic analysis to RPC detectors in the ATLAS experiment at CERN-LHC

    NASA Astrophysics Data System (ADS)

    de Asmundis, R.

    2007-06-01

    Starting from 2007 a large number (1200) Resistive Plate Chambers (RPC) detectors will be used as muon trigger detectors in the ATLAS Experiment at CERN-LHC accelerator. RPC are gaseous detector in which the quality and the stability of the gas mixture as well as the design of the gas supplying system, play a fundamental role in their functioning. RPC are foreseen to work more than ten years in the high radiation environment of ATLAS and the gas mixture acts really as a "lifeguard" for the detectors. For this reason a great attention has been devoted to the gas studies in order to optimize RPC performance, robustness and reliability in a high radiation environment. In this paper we describe the work done to decide how to supply and control in an optimal way the gas to the detectors, in order to ensure their best performance for a long time. The activity, based on Gas Chromatographic (GC) analysis, has been carried on a sample of final RPC working in radiation conditions much more intense than those foreseen for the ATLAS experiment. This has been possible using a high Gamma ray radiation facility available at CERN (GIF). The gas has been supplied using a system similar but at a reduced scale with respect to the final one and including: a recirculation circuit, a humidification module and a three stages purification subsystem.

  11. Thermophoretic separation of aerosol particles from a sampled gas stream

    DOEpatents

    Postma, Arlin K.

    1986-01-01

    A method for separating gaseous samples from a contained atmosphere that includes aerosol particles uses the step of repelling particles from a gas permeable surface or membrane by heating the surface to a temperature greater than that of the surrounding atmosphere. The resulting thermophoretic forces maintain the gas permeable surface clear of aerosol particles. The disclosed apparatus utilizes a downwardly facing heated plate of gas permeable material to combine thermophoretic repulsion and gravity forces to prevent particles of any size from contacting the separating plate surfaces.

  12. Toward a Micro Gas Chromatograph/Mass Spectrometer (GC/MS) System

    NASA Technical Reports Server (NTRS)

    Wiberg, D. V.; Eyre, F. B.; Orient, O.; Chutjian, A.; Garkarian, V.

    2001-01-01

    Miniature mass filters (e.g., quadrupoles, ion traps) have been the subject of several miniaturization efforts. A project is currently in progress at JPL to develop a miniaturized Gas Chromatograph/Mass Spectrometer (GC/MS) system, incorporating and/or developing miniature system components including turbomolecular pumps, scroll type roughing pump, quadrupole mass filter, gas chromatograph, precision power supply and other electronic components. The preponderance of the system elements will be fabricated using microelectromechanical systems (MEMS) techniques. The quadrupole mass filter will be fabricated using an X-ray lithography technique producing high precision, 5x5 arrays of quadrupoles with pole lengths of about 3 mm and a total volume of 27 cubic mm. The miniature scroll pump will also be fabricated using X-ray lithography producing arrays of scroll stages about 3 mm in diameter. The target detection range for the mass spectrometer is 1 to 300 atomic mass units (AMU) with are solution of 0.5 AMU. This resolution will allow isotopic characterization for geochronology, atmospheric studies and other science efforts dependant on the understanding of isotope ratios of chemical species. This paper will discuss the design approach, the current state-of-the art regarding the system components and the progress toward development of key elements. The full system is anticipated to be small enough in mass, volume and power consumption to allow in situ chemical analysis on highly miniaturized science craft for geochronology, atmospheric characterization and detection of life experiments applicable to outer planet roadmap missions.

  13. Headspace gas chromatographic method for determination of methyl bromide in food ingredients

    SciTech Connect

    DeVries, J.W.; Broge, J.M.; Schroeder, J.P.; Bowers, R.H.; Larson, P.A.; Burns, N.M.

    1985-11-01

    A headspace gas chromatographic (GC) method, which can be automated, has been developed for determination of methyl bromide. This method has been applied to wheat, flour, cocoa, and peanuts. Samples to be analyzed are placed in headspace sample vials, water is added, and the vials are sealed with Teflon-lined septa. After an appropriate equilibration time at 32 degrees C, the samples are analyzed within 10 h. A sample of the headspace is withdrawn and analyzed on a gas chromatograph equipped with an electron capture detector (ECD). Methyl bromide levels were quantitated by comparison of peak area with a standard. The standard was generated by adding a known amount of methyl bromide to a portion of the matrix being analyzed and which was known to be methyl bromide free. The detection limit of the method was 0.4 ppb. The coefficient of variation (CV) was 6.5% for wheat, 8.3% for flour, 3.3% for cocoa, and 11.6% for peanuts.

  14. Detection system for a gas chromatograph. [. cap alpha. -methylnaphthalene,. beta. -methylnapthalene

    DOEpatents

    Hayes, J.M.; Small, G.J.

    1982-04-26

    A method and apparatus are described for the quantitative analysis of vaporizable compounds, and in particular of polycyclic aromatic hydrocarbons which may be induced to fluoresce. The sample to be analyzed is injected into a gas chromatography column and is eluted through a narrow orifice into a vacuum chamber. The free expansion of the eluted sample into the vacuum chamber creates a supersonic molecular beam in which the sample molecules are cooled to the extent that the excited vibrational and rotational levels are substantially depopulated. The cooled molecules, when induced to fluoresce by laser excitation, give greatly simplified spectra suitable for analytical purposes. The laser induced fluorimetry provides great selectivity, and the gas chromatograph provides quantitative transfer of the sample to the molecular beam. 3 figures, 2 tables.

  15. Gas chromatographic determination of sulfuric acid and application to urinary sulfate.

    PubMed

    Masuoka, N; Ubuka, T; Kinuta, M; Yoshida, S; Taguchi, T

    1988-10-01

    A new gas chromatographic method for the determination of sulfate was developed. In this method, sulfate was quantitatively converted to a volatile derivative, dimethyl sulfate, by a two-step procedure. First, sulfate was converted to silver sulfate by reaction with silver oxide, and then to dimethyl sulfate by reaction with methyl iodide. The derivative was analyzed by gas chromatography. Methyl methanesulfonate was used as an internal standard. The method was applied to the determination of total urinary sulfate. Phosphate and chloride ions, which interfered with the present method, were eliminated with the use of basic magnesium carbonate and an excess of silver oxide, respectively. Recovery was over 96% when 5 to 40 mumol/ml of sulfate was added to human urine samples. PMID:3223336

  16. Simulation of elution profiles for two-dimensional dynamic gas chromatographic experiments.

    PubMed

    Trapp, Oliver; Shellie, Robert; Marriott, Philip; Schurig, Volker

    2003-09-01

    The interconversion of E and Z isomers of acetaldoxime 1 and butyraldoxime 2 have been investigated by comprehensive two-dimensional dynamic gas chromatography (DGCxDGC) and computer simulation. Time-resolved cryogenic modulation is capable of revealing the precise isomeric ratio as a fine structure under the dynamic elution profile, which is characterized in one-dimensional experiments by a plateau formation or peak coalescence caused by interconversion of the isomers during the separation process. The chromatographic theoretical plate model has been extended for the computer simulation of comprehensive two-dimensional dynamic chromatographic experiments. A novel program, ChromWin 2D, based on the new algorithm has been developed for computer simulation to evaluate and predict the elution profiles of DGCxDGC experiments. ChromWin 2D allows the determination of rate constants and barriers of isomerization, epimerization, and enantiomerization processes occurring during chromatographic separations. The Eyring activation parameters of the E/Z and Z/E isomerization barriers in the presence of the stationary phase BP21 (poly(ethylene glycol) terephthalate terminated) were determined by temperature-dependent experiments between 80 and 90 degrees C for 1 and 70 and 130 degrees C for 2. The thermodynamic Gibbs free energy of the E/Z equilibrium of the isomers has been determined from the time-resolved chromatograms by cryogenic modulation. The method described here constitutes a new and important tool for the determination of isomerization barriers, which are of great interest, for example, for the quantitative determination of derivatized aldehydes, such as dinitrophenylhydrazine derivatives, in trace analysis.

  17. Interfacing a robotic station with a gas chromatograph for the full automation of the determination of organochlorine pesticides in vegetables

    SciTech Connect

    Torres, P.; Luque de Castro, M.D.

    1996-12-31

    A fully automated method for the determination of organochlorine pesticides in vegetables is proposed. The overall system acts as an {open_quotes}analytical black box{close_quotes} because a robotic station performs the prelimninary operations, from weighing to capping the leached analytes and location in an autosampler of an automated gas chromatograph with electron capture detection. The method has been applied to the determination of lindane, heptachlor, captan, chlordane and metoxcychlor in tea, marjoram, cinnamon, pennyroyal, and mint with good results in most cases. A gas chromatograph has been interfaced to a robotic station for the determination of pesticides in vegetables. 15 refs., 4 figs., 2 tabs.

  18. Gas-liquid chromatographic headspace technique for determination of vinyl chloride in corn oil and three food-simulating solvents.

    PubMed

    Diachenko, G W; Breder, C V; Brown, M E; Dennison, J L

    1977-05-01

    A gas-liquid chromatographic headspace technique for the determination of vinyl chloride (VC) in corn oil, 50% ethanol, 3% acetic acid, and n-heptane is described. These food-simulating solvents and the corn oil are placed in septum-sealed bottles and heated to 90 degrees C, and aliquots of headspace vapor are injected into a gas-liquid chromatograph equipped with a flame ionization detector. VC may be quantitated at concentrations of 1 ppb or less. This technique was used to measure the migration of VC into corn oil and 50% ethanol from 2 unplasticized polyvinyl chloride sheets containing 0.28 and 0.44 ppm residual monomer.

  19. Gas chromatographic determination of volatile congeners in spirit drinks: interlaboratory study.

    PubMed

    Kelly, J; Chapman, S; Brereton, P; Bertrand, A; Guillou, C; Wittkowski, R

    1999-01-01

    An interlaboratory study of a gas chromatographic (GC) method for the determination of volatile congeners in spirit drinks was conducted; 31 laboratories from 8 countries took part in the study. The method uses GC with flame ionization detection and incorporates several quality control measures which permit the choice of chromatographic system and conditions to be selected by the user. Spirit drink samples were prepared and sent to participants as 10 blind duplicate or split-level test materials for the determination of 1,1-diethoxyethane (acetal), 2-methylbutan-1-ol (active amyl alcohol), 3-methylbutan-1-ol (isoamyl alcohol), methanol (methyl alcohol), ethyl ethanoate (ethyl acetate), butan-1-ol (n-butanol), butan-2-ol (sec-butanol), 2-methylpropan-1-ol (isobutyl alcohol), propan-1-ol (n-propanol), and ethanal (acetaldehyde). The precision of the method for 9 of the 10 analytes was well within the range predicted by the Horwitz equation. The precision of the most volatile analyte, ethanal, was just above statistically predicted levels. This method is recommended for official regulatory purposes. PMID:10589492

  20. A gas chromatograph/mass spectrometry method for determining isotopic distributions in organic compounds used in the chemical approach to stable isotope separation

    SciTech Connect

    Martinez, A.M.; Spall, W.D.; Smith, B.F.

    1990-01-01

    A variety of gas chromatograph/mass spectrometry (GC/MS) methods have been developed to resolve benzene, benzophenone, anthracene, fluorenone, and their respective stable isotope analogs from other components by gas chromatography. The ratio of stable isotope-labeled material to natural isotopic abundance compounds is determined from the mass spectra averaged across the chromatographic peak. Both total ion and selective ion chromatographic approaches were used for relative data and comparison. 9 refs., 11 tabs.

  1. Workshop on Aerosols and Particulates from Aircraft Gas Turbine Engines

    NASA Technical Reports Server (NTRS)

    Wey, Chown Chou (Compiler)

    1999-01-01

    In response to the National Research Council (NRC) recommendations, the Workshop on Aerosols and Particulates from Aircraft Gas Turbine Engines was organized by the NASA Lewis Research Center and held on July 29-30, 1997 at the Ohio Aerospace Institute in Cleveland, Ohio. The objective is to develop consensus among experts in the field of aerosols from gas turbine combustors and engines as to important issues and venues to be considered. Workshop participants' expertise included engine and aircraft design, combustion processes and kinetics, atmospheric science, fuels, and flight operations and instrumentation.

  2. Gas and aerosol fluxes. [emphasizing sulfur, nitrogen, and carbon

    NASA Technical Reports Server (NTRS)

    Martens, C. S.

    1980-01-01

    The development of remote sensing techniques to address the global need for accurate distribution and flux determinations of both man made and natural materials which affect the chemical composition of the atmosphere, the heat budget of the Earth, and the depletion, of stratospheric ozone is considered. Specifically, trace gas fluxes, sea salt aerosol production, and the effect of sea surface microlayer on gas and aerosol fluxes are examined. Volatile sulfur, carbon, nitrogen, and halocarbon compounds are discussed including a statement of the problem associated with each compound or group of compounds, a brief summary of current understanding, and suggestions for needed research.

  3. Tropospheric Trace Gas Interactions with Aerosols

    NASA Technical Reports Server (NTRS)

    Penner, Joyce E.; Maddrea, George L., Jr. (Technical Monitor)

    2002-01-01

    Tropospheric aerosols are of considerable environmental importance. They modify the radiative budget of Earth by scattering and absorbing radiation, and by providing nuclei for cloud formation. Additionally, they provide surfaces for heterogeneous and multiphase reactions that affect tropospheric chemistry. For example, Dentener and Crutzen (1993) showed that reactions of N2O5 and NO3 with sulfate aerosols may significantly alter the tropospheric concentrations of NO(x), O3, and OH by converting NOx to HNO3 which is rapidly removed by precipitation. Zhang et al. (1994) assumed these same reactions would occur on dust aerosols and showed that dust outbreaks may reduce NO(x) levels by up to 50%. Dentener et al. (1996) studied the possible effect of reactions on dust on sulfate, nitrate, and O3 concentration. Heterogeneous and multiphase reactions on aerosols may also perturb the sulfur cycle the chlorine cycle and the bromine cycle. Because these reactions can release free chlorine and free bromine they might lead to the destruction of ozone in the marine boundary layer that may be important to include in models of tropospheric chemistry. The goal of our proposed work is to examine the role of heterogeneous and multiphase reactions in the tropospheric cycles of reactive nitrogen and sulfur.

  4. Capillary gas chromatographic determination of cyclohexanone and 2-ethyl-1-hexanol leached from solution administration sets.

    PubMed

    Danielson, J W

    1991-01-01

    A capillary gas chromatographic method is described for the determination of cyclohexanone and 2-ethyl-1-hexanol leached from solution administration sets. A preliminary study was made of compounds leached from solution administration sets by 5% sodium bicarbonate solution (pH 8.1), 0.9% sodium chloride solution (pH 6.8), and water. Water was selected as the leaching solvent because similar quantities of the compounds were leached into water and into both types of parenteral solutions. The correlation coefficients were 0.99977 for cyclohexanone and 0.99974 for 2-ethyl-1-hexanol, and recoveries were good (93-94%). Five administration sets from each of 2 manufacturers were analyzed by this method. The amounts of cyclohexanone that were leached from the individual sets varied considerably; however, similar quantities were leached from sets of both manufacturers. 2-Ethyl-1-hexanol was also found in extracts from each of the sets analyzed.

  5. Gas-liquid chromatographic properties of positional isomers of methyl thia, selena, and tellura laurate analogs.

    PubMed

    Jie, M S; Bakare, O; Cheung, Y K; Chau, S H

    1997-06-01

    Gas-liquid chromatographic analyses of three complete series of synthetic positional isomers of methyl thia, selena, and tellura laurate analogs were carried on a nonpolar (SE-30) and a polar (SP-2330) stationary phase. The average ECL (equivalent chain length) values of the thia, selena, and tellura laurate on SE-30 stationary phase were 13.8, 14.8, and 15.7, respectively, while on SP-2330 the average values for the same series were 17.1, 19.0, and 19.1, respectively. Positional isomers with the heteroatom at the 2-position exhibited the lowest ECL values, while those with the heteroatom at the omega-1 position gave the highest ECL values and were readily separated from the other positional isomers of the same series of analogs by this technique.

  6. The current practice in the application of chemometrics for correlation of sensory and gas chromatographic data.

    PubMed

    Seisonen, Sirli; Vene, Kristel; Koppel, Kadri

    2016-11-01

    A lot of research has been conducted in correlating the sensory properties of food with different analytical measurements in recent years. Various statistical methods have been used in order to get the most reliable results and to create prediction models with high statistical performance. The current review summarises the latest practices in the field of correlating attributes from sensory analysis with volatile data obtained by gas chromatographic analysis. The review includes the origin of the data, different pre-processing and variable selection methods and finally statistical methods of analysis and validation. Partial least squares regression analysis appears as the most commonly used statistical method in the area. The main shortcomings were identified in the steps of pre-processing, variable selection and also validation of models that have not gained enough attention. As the association between volatiles and sensory perception is often nonlinear, future studies should test the application of different nonlinear techniques. PMID:27211679

  7. Determination and discrimination of biodiesel fuels by gas chromatographic and chemometric methods

    NASA Astrophysics Data System (ADS)

    Milina, R.; Mustafa, Z.; Bojilov, D.; Dagnon, S.; Moskovkina, M.

    2016-03-01

    Pattern recognition method (PRM) was applied to gas chromatographic (GC) data for a fatty acid methyl esters (FAME) composition of commercial and laboratory synthesized biodiesel fuels from vegetable oils including sunflower, rapeseed, corn and palm oils. Two GC quantitative methods to calculate individual fames were compared: Area % and internal standard. The both methods were applied for analysis of two certified reference materials. The statistical processing of the obtained results demonstrates the accuracy and precision of the two methods and allows them to be compared. For further chemometric investigations of biodiesel fuels by their FAME-profiles any of those methods can be used. PRM results of FAME profiles of samples from different vegetable oils show a successful recognition of biodiesels according to the feedstock. The information obtained can be used for selection of feedstock to produce biodiesels with certain properties, for assessing their interchangeability, for fuel spillage and remedial actions in the environment.

  8. Validation study of gas chromatographic determination of pentachlorophenol in animal liver

    SciTech Connect

    Gillard, D.; Epstein, R.L.; Ashworth, R.B.; Curry, K.; Nathan, Q.

    1988-01-01

    A validation study was conducted of a gas chromatographic procedure for the determination of pentachlorophenol (PCP) in chicken, pork, and beef liver. Five analysts representing 5 laboratories analyzed randomly numbered blind duplicates at 3 fortified tissue concentrations and one incurred tissue on 2 consecutive days. The PCP concentrations ranged from approximately 40 to 400 parts per billion (ppb). All data were reported to 3 significant figures in ppb. The coefficients of variation for repeatability were between 2.8 and 8.5%, except for the beef liver, at a mean value of 80 ppb PCP, where the CV was 11.3%. The CVs for reproducibility were in the range of 9.7 - 16.5% with little significant difference by species. The CV asymptotically approached 10% as the PCP level increased.

  9. Advances in Gas Chromatographic Methods for the Identification of Biomarkers in Cancer

    PubMed Central

    Kouremenos, Konstantinos A.; Johansson, Mikael; Marriott, Philip J.

    2012-01-01

    Screening complex biological specimens such as exhaled air, tissue, blood and urine to identify biomarkers in different forms of cancer has become increasingly popular over the last decade, mainly due to new instruments and improved bioinformatics. However, despite some progress, the identification of biomarkers has shown to be a difficult task with few new biomarkers (excluding recent genetic markers) being considered for introduction to clinical analysis. This review describes recent advances in gas chromatographic methods for the identification of biomarkers in the detection, diagnosis and treatment of cancer. It presents a general overview of cancer metabolism, the current biomarkers used for cancer diagnosis and treatment, a background to metabolic changes in tumors, an overview of current GC methods, and collectively presents the scope and outlook of GC methods in oncology. PMID:23074381

  10. Convenient headspace gas chromatographic determination of azide in blood and plasma.

    PubMed

    Meatherall, Robert; Palatnick, Wes

    2009-10-01

    Azide in human blood and plasma samples was derivatized with propionic anhydride in a headspace vial without prior sample preparation. The reaction proceeds quickly at room temperature to form propionyl azide. A portion of the headspace was assayed by gas chromatography with a nitrogen-phosphorus detector. In the heated injector of the gas chromatograph, the propionyl azide undergoes thermal rearrangement, forming ethyl isocyanate, which is subsequently chromatographed and detected. Propionitrile was used as the internal standard. The method is linear to at least 20 microg/mL. Limit of quantitation was 0.04 microg/mL, and the within-run coefficient of variation was 5.6% at 1 microg/mL. There was no interference from cyanide. A fatality report in which blood and plasma azide concentrations from a 59-year-old man were monitored for 24 h following the ingestion of an unknown amount of sodium azide is presented. The patient became critically ill after his self-inflicted sodium azide ingestion. He was intubated and treated with vasopressors and aggressive supportive care, including extracorporeal membrane oxygenation therapy, in the intensive care facility but died from neurological brain damage secondary to anoxia. On admission, 1.4 h after ingestion, his azide level was 5.6 microg/mL (blood); shortly thereafter, it had risen to 13.7 microg/mL (plasma) and, subsequently, was projected to have been eliminated by 16.7 h. No azide was detected in the postmortem blood and vitreous humor.

  11. Linear solvation energy relationships as classifiers in non-target analysis - a gas chromatographic approach.

    PubMed

    Ulrich, Nadin; Mühlenberg, Jana; Retzbach, Heiko; Schüürmann, Gerrit; Brack, Werner

    2012-11-16

    Linear solvation energy relationships (LSERs) are applied as classifiers to predict the logarithmic retention factors logk from the structures of candidate compounds in non-target analysis. By comparison of the predicted value with the experimentally determined logk, progressive exclusion of candidates is done. The approach is based on the determination of stationary phase parameters to describe ten different gas chromatographic columns under four isothermal conditions. To demonstrate retention prediction and the application of the classifier model, twelve compounds with the molecular formula C(12)H(10)O(2) were selected, while experimental logk values were compared to the predicted values and exclusion of potential candidate compounds was performed. The analytical power of the approach was demonstrated on the basis of experimentally determined compound descriptors achieved from gas chromatographic measurements. The prediction got less accurate when calculated compound descriptors were employed. For the time being insufficient precision in estimating the descriptors limits the possibility to exclude candidate compounds in non-target analysis. It is expected that new approaches to estimate compound descriptors, will improve this situation. At present, the insufficient accuracy of descriptor estimates can be dealt with larger prognosis intervals. Furthermore, the combination of two stationary phases with corresponding retention prediction further advanced the exclusion of potential candidates. The most appropriate pair of stationary phases was selected by the application of four different orthogonal strategies. In addition, the classifier was applied for a validation set with different molecular composition, where column selection was considered on the basis of the differences in the compound descriptors of the corresponding candidate compounds.

  12. Design and Performance of a Gas Chromatograph for Automatic Monitoring of Pollutants in Ambient Air

    NASA Technical Reports Server (NTRS)

    Villalobos, R.; Stevens, D.; LeBlanc, R.; Braun, L.

    1971-01-01

    In recent years, interest in air pollution constituents has focused on carbon monoxide and hydrocarbons as prime components of polluted air. Instrumental methods have been developed, and commercial instruments for continuous monitoring of these components have been available for a number of years. For the measurement of carbon monoxide, non-dispersive infrared spectroscopy has been the accepted tool, in spite of its marginal sensitivity at low parts-per-million levels. For continuously monitoring total hydrocarbons, the hydrogen flame ionization analyzer has been widely accepted as the preferred method. The inadequacy of this latter method became evident when it was concluded that methane is non-reactive and cannot be considered a contaminant even though present at over 1 ppm in the earth's atmosphere. Hence, the need for measuring methane separately became apparent as a means of measuring the reactive and potentially harmful non-methane hydrocarbons fraction. A gas chromatographic method for the measurement of methane and total hydrocarbons which met these requirements has been developed. In this technique, methane was separated on conventional gas chromatographic columns and detected by a hydrogen flame ionization detector (FID) while the total hydrocarbons were obtained by introducing a second sample directly into the FID without separating the various components. The reactive, or non-methane hydrocarbons, were determined by difference. Carbon monoxide was also measured after converting to methane over a heated catalyst to render it detectable by the FID. The development of this method made it possible to perform these measurements with a sensitivity of as much as 1 ppm full scale and a minimum detectability of 20 ppb. Incorporating this technique, criteria were developed by APCO for a second generation continuous automatic instrument for atmospheric monitoring stations.

  13. 10 CFR 30.20 - Gas and aerosol detectors containing byproduct material.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Gas and aerosol detectors containing byproduct material... LICENSING OF BYPRODUCT MATERIAL Exemptions § 30.20 Gas and aerosol detectors containing byproduct material... distribution gas and aerosol detectors containing byproduct material, any person is exempt from...

  14. A purge-and-trap capillary column gas chromatographic method for the measurement of halocarbons in water and air

    SciTech Connect

    Happell, J.D.; Wallace, D.W.R.; Wills, K.D.; Wilke, R.J.; Neill, C.C.

    1996-06-01

    This report describes an automated, accurate, precise and sensitive capillary column purge- and -trap method capable of quantifying CFC-12, CFC-11, CFC-113, CH{sub 3}CCL{sub 3}, and CCL{sub 4} during a single chromatographic analysis in either water or gas phase samples.

  15. Oral intake of a toluene-containing thinner. Effects and headspace gas chromatographic analytical diagnosis.

    PubMed

    Zahlsen, K; Rygnestad, T; Nilsen, O G

    1985-01-01

    After an accidental oral intake of a paint thinner, the constituents were identified in stomach content using headspace gas chromatography. The composition indicated ingestion of a commonly used thinner containing 60-70% toluene, 20-25% n-butylacetate and 10-15% of ethanol. A toluene concentration of 22.0 mg/kg was measured in serum in contrast to n-butylacetate which was not detected. Ethanol concentration was 1.85 g/kg, most of this was due to ethanol ingestion before the intake of thinner. The half life of toluene in serum was 8.5 h initially, which increased to 14 h after 19 h. An effect on liver function was demonstrated by increased activity of serum transaminases. Compared with the upper normal limits ASAT and ALAT were increased by 6 and 2.5 times, respectively. For both parameters the highest activity was seen 40 hours after admission and normal levels were achieved after 7 days. It is concluded that toluene is readily absorbed by ingestion of toluene-containing thinners, and that the function of the human liver is transiently affected. For screening purposes gas chromatography proved to be a useful method for the analytical diagnosis in cases of organic solvent intoxication. The use of the headspace technique further improved the speed of analysis and eliminated contamination of the gas chromatographic system. PMID:3868371

  16. On-line gas chromatographic analysis of higher alcohol synthesis products from syngas.

    PubMed

    Andersson, Robert; Boutonnet, Magali; Järås, Sven

    2012-07-20

    An on-line gas chromatographic (GC) system has been developed for rapid and accurate product analysis in catalytic conversion of syngas (a mixture of H₂ and CO) to alcohols, so called "higher alcohol synthesis (HAS)". Conversion of syngas to higher alcohols is an interesting second step in the route of converting coal, natural gas and possibly biomass to liquid alcohol fuel and chemicals. The presented GC system and method are developed for analysis of the products formed from syngas using alkali promoted MoS₂ catalysts, however it is not limited to these types of catalysts. During higher alcohol synthesis not only the wanted short alcohols (∼C₂-C₅) are produced, but also a great number of other products in smaller or greater amounts, they are mainly short hydrocarbons (olefins, paraffins, branched, non-branched), aldehydes, esters and ketones as well as CO₂, H₂O. Trace amounts of sulfur-containing compounds can also be found in the product effluent when sulfur-containing catalysts are used and/or sulfur-containing syngas is feed. In the presented GC system, most of them can be separated and analyzed within 60 min without the use of cryogenic cooling. Previously, product analysis in "higher alcohol synthesis" has in most cases been carried out partly on-line and partly off-line, where the light gases (gases at room temp) are analyzed on-line and liquid products (liquid at room temp) are collected in a trap for later analysis off-line. This method suffers from many drawbacks compared to a complete on-line GC system. In this paper an on-line system using an Agilent 7890 gas chromatograph equipped with two flame ionization detectors (FID) and a thermal conductivity detector (TCD), together with an Agilent 6890 with sulfur chemiluminescence dual plasma detector (SCD) is presented. A two-dimensional GC system with Deans switch (heart-cut) and two capillary columns (HP-FFAP and HP-Al₂O₃) was used for analysis of the organic products on the FIDs. Light

  17. Thermophoretic separation of aerosol particles from a sampled gas stream

    DOEpatents

    Postma, A.K.

    1984-09-07

    This disclosure relates to separation of aerosol particles from gas samples withdrawn from within a contained atmosphere, such as containment vessels for nuclear reactors or other process equipment where remote gaseous sampling is required. It is specifically directed to separation of dense aerosols including particles of any size and at high mass loadings and high corrosivity. The United States Government has rights in this invention pursuant to Contract DE-AC06-76FF02170 between the US Department of Energy and Westinghouse Electric Corporation.

  18. Capillary gas chromatographic analysis of nitrogen dioxide and pans with luminol chemiluminescent detection.

    SciTech Connect

    Gaffney, J. S.; Bornick, R. M.; Chen, Y.-H.; Marley, N. A.; Environmental Research

    1998-01-01

    Peroxyacyl nitrates (PANs) and nitrogen dioxide are important atmospheric air pollutants in the troposphere. These atmospheric nitrogen species are strongly coupled chemically by a clearly temperature-dependent equilibrium in the troposphere. A chemical method that can measure both nitrogen dioxide and PANs rapidly and with sub-part-per-billion detection is described that is based upon a modified luminol detection system coupled to a capillary gas chromatographic column by using helium as a carrier. The system can readily separate and detect nitrogen dioxide, peroxyacetyl nitrate, peroxyproprionyl nitrate, and peroxybutyrl nitrate with detection limits in the low tens of parts per trillion with total analysis time of less than 1 min. Calibration of PAN by thermal decomposition to nitrogen dioxide is demonstrated with PAN detection sensitivities approximately 75% of the sensitivities observed for NO2 luminol detection by using helium as a carrier gas. The advantages of this method for simultaneous measurement of nitrogen dioxide and PANs over ozone chemiluminescent detection and electron capture detection are discussed, as well as potential applications of this method for heterogeneous surface chemistry studies of PANs and nitrogen dioxide and for tropospheric measurements.

  19. Autonomous gas chromatograph system for Thermal Enhanced Vapor Extraction System (TEVES) proof of concept demonstration

    SciTech Connect

    Peter, F.J.; Laguna, G.R.

    1996-09-01

    An autonomous gas chromatograph system was designed and built to support the Thermal Enhanced Vapor Extraction System (TEVES) demonstration. TEVES is a remediation demonstration that seeks to enhance an existing technology (vacuum extraction) by adding a new technology (soil heating). A pilot scale unit was set up at one of the organic waste disposal pits at the Sandia National Laboratories Chemical Waste Landfill (CWL) in Tech Area 3. The responsibility for engineering a major part of the process instrumentation for TEVES belonged to the Manufacturing Control Subsystems Department. The primary mission of the one-of-a-kind hardware/software system is to perform on-site gas sampling and analysis to quantify a variety of volatile organic compounds (VOCs) from various sources during TEVES operations. The secondary mission is to monitor a variety of TEVES process physical parameters such as extraction manifold temperature, pressure, humidity, and flow rate, and various subsurface pressures. The system began operation in September 1994 and was still in use on follow-on projects when this report was published.

  20. Gas chromatographic and mass spectrometric analysis of polychlorinated biphenyls in human placenta and cord blood

    SciTech Connect

    Ando, M.; Saito, H.; Wakisaka, I.

    1986-10-01

    Gas chromatographic and mass spectrometric analyses of polychlorinated biphenyls (PCBs) in placenta, maternal blood, cord blood, and milk were carried out. Trichlorobiphenyl, tetrachlorobiphenyl, pentachlorobiphenyls, and hexachlorobiphenyls were identified by the mass chromatogram and the mass spectra. Some minor peaks of PCBs were identified by gas chromatography. The relationship between the PCB concentration in placenta and that in milk is different in each PCB congener. The higher the chlorine content of the PCB congener, the more significant the correlation. No significant but a low negative correlation exists between the concentration of some PCB congeners in the placenta and that in cord blood. On the other hand, a significant linear correlation exists between the concentration of hexachlorobenzene in the placenta and that in cord blood. The transplacental transport of each PCB congener varied depending upon its chemical nature. Trichlorobiphenyl and tetrachlorobiphenyl were more transferable than hexachlorobiphenyls. The results show that the placenta and cord blood are useful human samples to analyze the body burden of environmental pollutants and to estimate their transfer from mother to fetus.

  1. Rapid detection of bacteria with miniaturized pyrolysis-gas chromatographic analysis

    NASA Astrophysics Data System (ADS)

    Mowry, Curtis; Morgan, Catherine H.; Baca, Quentin; Manginell, Ronald P.; Kottenstette, Richard J.; Lewis, Patrick; Frye-Mason, Gregory C.

    2002-02-01

    Rapid detection and identification of bacteria and other pathogens is important for many civilian and military applications. The profiles of biological markers such as fatty acids can be used to characterize biological samples or to distinguish bacteria at the gram-type, genera, and even species level. Common methods for whole cell bacterial analysis are neither portable nor rapid, requiring lengthy, labor intensive sample preparation and bench-scale instrumentation. These methods chemically derivatize fatty acids to produce more volatile fatty acid methyl esters (FAMEs) that can be separated and analyzed by a gas chromatograph (GC)/mass spectrometer. More recent publications demonstrate decreased sample preparation time with in situ derivatization of whole bacterial samples using pyrolysis/derivatization. Ongoing development of miniaturized pyrolysis/GC instrumentation by this department capitalizes on Sandia advances in the field of microfabricated chemical analysis systems ((mu) ChemLab). Microdevices include rapidly heated stages capable of pyrolysis or sample concentration, gas chromatography columns, and surface acoustic wave (SAW) sensor arrays. We will present results demonstrating the capabilities of these devices toward fulfilling the goal of portable, rapid detection and early warning of the presence of pathogens in air or water.

  2. Fuzzy C-means clustering for chromatographic fingerprints analysis: A gas chromatography-mass spectrometry case study.

    PubMed

    Parastar, Hadi; Bazrafshan, Alisina

    2016-03-18

    Fuzzy C-means clustering (FCM) is proposed as a promising method for the clustering of chromatographic fingerprints of complex samples, such as essential oils. As an example, secondary metabolites of 14 citrus leaves samples are extracted and analyzed by gas chromatography-mass spectrometry (GC-MS). The obtained chromatographic fingerprints are divided to desired number of chromatographic regions. Owing to the fact that chromatographic problems, such as elution time shift and peak overlap can significantly affect the clustering results, therefore, each chromatographic region is analyzed using multivariate curve resolution-alternating least squares (MCR-ALS) to address these problems. Then, the resolved elution profiles are used to make a new data matrix based on peak areas of pure components to cluster by FCM. The FCM clustering parameters (i.e., fuzziness coefficient and number of cluster) are optimized by two different methods of partial least squares (PLS) as a conventional method and minimization of FCM objective function as our new idea. The results showed that minimization of FCM objective function is an easier and better way to optimize FCM clustering parameters. Then, the optimized FCM clustering algorithm is used to cluster samples and variables to figure out the similarities and dissimilarities among samples and to find discriminant secondary metabolites in each cluster (chemotype). Finally, the FCM clustering results are compared with those of principal component analysis (PCA), hierarchical cluster analysis (HCA) and Kohonon maps. The results confirmed the outperformance of FCM over the frequently used clustering algorithms.

  3. Formation of Secondary Particulate Matter by Reactions of Gas Phase Hexanal with Sulfate Aerosol Particles

    NASA Astrophysics Data System (ADS)

    Zhang, J.

    2003-12-01

    The formation of secondary particulate matter from the atmospheric oxidation of organic compounds can significantly contribute to the particulate burden, but the formation of organic secondary particulate matter is poorly understood. One way of producing organic secondary particulate matter is the oxidation of hydrocarbons with seven or more carbon atoms to get products with low vapor pressure. However, several recent reports suggest that relatively low molecular weight carbonyls can enter the particle phase by undergoing heterogeneous reactions. This may be a very important mechanism for the formation of organic secondary particulate matter. Atmospheric aldehydes are important carbonyls in the gas phase, which form via the oxidation of hydrocarbons emitted from anthropogenic and biogenic sources. In this poster, we report the results on particle growth by the heterogeneous reactions of hexanal. A 5 L Continuous Stirred Tank Reactor (CSTR) is set up to conduct the reactions in the presence of seed aerosol particles of deliquesced ammonia bisulfate. Hexanal is added into CSTR by syringe pump, meanwhile the concentrations of hexanal are monitored with High Pressure Liquid Chromatograph (HPLC 1050). A differential Mobility Analyzer (TSI 3071) set to an appropriate voltage is employed to obtain monodisperse aerosols, and another DMA associated with a Condensation Nuclear Counter (TSI 7610) is used to measure the secondary particle size distribution by the reaction in CSTR. This permits the sensitive determination of particle growth due to the heterogeneous reaction, very little growth occurs when hexanal added alone. Results for the simultaneous addition of hexanal and alcohols will also be presented.

  4. Characterization of gas-aerosol interaction kinetics using morphology dependent stimulated Raman scattering. Final technical report

    SciTech Connect

    Aker, P.M.

    1992-12-31

    A research program on the influence of aerosol surface structure on the kinetics of gas-aerosol interactions is proposed. The experiments involve measuring changes in gas phase chemical reaction rates as a function of exposure to a specific aerosol. Aerosols with differing surface properties will be generated by changing the composition and/or temperature of the material making up the aerosol. Kinetic data generated can be used directly in atmospheric modelling calculations. The surface structure of the aerosol will be measured, both before and after reaction, using morphology-dependent enhancement of simulated Raman scattering (MDSRS). Information about the detailed dynamics of gas-aerosol interactions can be obtained by correlating the change in the reaction rate with change in surface structure and by monitoring the change in aerosol surface structure during the course of the reaction. Studies will focus on the condensation and oxidation of sulfur species (sulfur dioxide and dimethyl sulfide) on water aerosols.

  5. Characterization of gas-aerosol interaction kinetics using morphology dependent stimulated Raman scattering

    SciTech Connect

    Aker, P.M.

    1992-01-01

    A research program on the influence of aerosol surface structure on the kinetics of gas-aerosol interactions is proposed. The experiments involve measuring changes in gas phase chemical reaction rates as a function of exposure to a specific aerosol. Aerosols with differing surface properties will be generated by changing the composition and/or temperature of the material making up the aerosol. Kinetic data generated can be used directly in atmospheric modelling calculations. The surface structure of the aerosol will be measured, both before and after reaction, using morphology-dependent enhancement of simulated Raman scattering (MDSRS). Information about the detailed dynamics of gas-aerosol interactions can be obtained by correlating the change in the reaction rate with change in surface structure and by monitoring the change in aerosol surface structure during the course of the reaction. Studies will focus on the condensation and oxidation of sulfur species (sulfur dioxide and dimethyl sulfide) on water aerosols.

  6. Application of a Modified Gas Chromatograph to Analyze Space Experiment Combustion Gases on Space Shuttle Mission STS-94

    NASA Technical Reports Server (NTRS)

    Coho, William K.; Weiland, Karen J.; VanZandt, David M.

    1998-01-01

    A space experiment designed to study the behavior of combustion without the gravitational effects of buoyancy was launched aboard the Space Shuttle Columbia on July 1, 1997. The space experiment, designated as Combustion Module-1 (CM-1), was one of several manifested on the Microgravity Sciences Laboratory - 1 (MSL-1) mission. The launch, designated STS-94, had the Spacelab Module as the payload, in which the MSL-1 experiments were conducted by the Shuttle crewmembers. CM-1 was designed to accommodate two different combustion experiments during MSL-1. One experiment, the Structure of Flame Balls at Low Lewis-number experiment (SOFBALL), required gas chromatography analysis to verify the composition of the known, premixed gases prior to combustion, and to determine the remaining reactant and the products resulting from the combustion process in microgravity. A commercial, off-the-shelf, dual-channel micro gas chromatograph was procured and modified to interface with the CM-1 Fluids Supply Package and the CM-1 Combustion Chamber, to accommodate two different carrier gases, each flowing through its own independent column module, to withstand the launch environment of the Space Shuttle, to accept Spacelab electrical power, and to meet the Spacelab flight requirements for electromagnetic interference (EMI) and offgassing. The GC data was down linked to the Marshall Space Flight Center for near-real time analysis, and stored on-orbit for post-flight analysis. The gas chromatograph operated successfully during the entire SOFBALL experiment and collected 309 runs. Because of the constraints imposed upon the gas chromatograph by the CM-1 hardware, system and operations, it was unable to measure the gases to the required accuracy. Future improvements to the system for a re-flight of the SOFBALL experiment are expected to enable the gas chromatograph to meet all the requirements.

  7. Enhancement of aerosol responses to changes in emissions over East Asia by gas-oxidant-aerosol coupling and detailed aerosol processes

    NASA Astrophysics Data System (ADS)

    Matsui, H.; Koike, M.

    2016-06-01

    We quantify the responses of aerosols to changes in emissions (sulfur dioxide, black carbon (BC), primary organic aerosol, nitrogen oxides (NOx), and volatile organic compounds) over East Asia by using simulations including gas-oxidant-aerosol coupling, organic aerosol (OA) formation, and BC aging processes. The responses of aerosols to NOx emissions are complex and are dramatically changed by simulating gas-phase chemistry and aerosol processes online. Reduction of NOx emissions by 50% causes a 30-40% reduction of oxidant (hydroxyl radical and ozone) concentrations and slows the formation of sulfate and OA by 20-30%. Because the response of OA to changes in NOx emissions is sensitive to the treatment of emission and oxidation of semivolatile and intermediate volatility organic compounds, reduction of the uncertainty in these processes is necessary to evaluate gas-oxidant-aerosol coupling accurately. Our simulations also show that the sensitivity of aerosols to changes in emissions is enhanced by 50-100% when OA formation and BC aging processes are resolved in the model. Sensitivity simulations show that the increase of NOx emissions from 1850 to 2000 explains 70% (40%) of the enhancement of aerosol mass concentrations (direct radiative effects) over East Asia during that period through enhancement of oxidant concentrations and that this estimation is sensitive to the representation of OA formation and BC aging processes. Our results demonstrate the importance of simultaneous simulation of gas-oxidant-aerosol coupling and detailed aerosol processes. The impact of NOx emissions on aerosol formation will be a key to formulating effective emission reduction strategies such as BC mitigation and aerosol reduction policies in East Asia.

  8. Gas chromatographic method for the determination of hexaconazole residues in black tea*

    PubMed Central

    Karthika, Chinnachamy; Sachin, Paul James

    2008-01-01

    A highly reliable, quantitative and sensitive analytical method for determining the residues of the fungicide, hexaconazole in black tea is described. The proposed method is based on liquid-liquid extraction followed by gas chromatographic determination, using nitrogen phosphorus detector (GC-NPD) for the identification and quantitation of hexaconazole. The most appropriate solvent mixture for extracting hexaconazole residues from black tea was n-hexane:acetone at 1:1 (v/v). The extract was cleaned up by adsorption column chromatography using activated florisil. Performance of the method was assessed by evaluating quality parameters such as recovery value, repeatability, reproducibility, linearity and limits of detection and quantitation. When the method was assessed for repeatability, the percentage of recovery ranged between 86% and 96% while the relative standard deviation was between 0.30% and 2.35%. In studies on reproducibility the recovery ranged from 81% to 85% and relative standard deviation from 1.68% to 5.13%, implying that the method was reliable. A field trial was conducted to verify the application of this method with real samples. Results prove that the validated method was suitable for extracting hexaconazole residues. PMID:18257139

  9. Cross-column prediction of gas-chromatographic retention indices of saturated esters.

    PubMed

    D'Archivio, Angelo Antonio; Maggi, Maria Anna; Ruggieri, Fabrizio

    2014-08-15

    We combine computational molecular descriptors and variables related with the gas-chromatographic stationary phase into a comprehensive model able to predict the retention of solutes in external columns. To explore the quality of various approaches based on alternative column descriptors, we analyse the Kováts retention indices (RIs) of 90 saturated esters collected with seven columns of different polarity (SE-30, OV-7, DC-710, OV-25, XE-60, OV-225 and Silar-5CP). Cross-column retention prediction is evaluated on an internal validation set consisting of data of 40 selected esters collected with each of the seven columns, sequentially excluded from calibration. The molecular descriptors are identified by a genetic algorithm variable selection method applied to a large set of non-empirical structural quantities aimed at finding the best multi-linear quantitative structure-retention relationship (QSRR) for the column OV-25 having intermediate polarity. To describe the columns, we consider the sum of the first five McReynolds phase constants and, alternatively, the coefficients of the corresponding QSRRs. Moreover, the mean RI value for the subset of esters used in QSRR calibration or RIs of a few selected compounds are used as column descriptors. For each combination of solute and column descriptors, the retention model is generated both by multi-linear regression and artificial neural network regression.

  10. Micro-machined planar field asymmetric ion mobility spectrometer as a gas chromatographic detector

    NASA Technical Reports Server (NTRS)

    Eiceman, G. A.; Nazarov, E. G.; Miller, R. A.; Krylov, E. V.; Zapata, A. M.

    2002-01-01

    A planar high field asymmetric waveform ion mobility spectrometer (PFAIMS) with a micro-machined drift tube was characterized as a detector for capillary gas chromatography. The performance of the PFAIMS was compared directly to that of a flame ionization detector (FID) for the separation of a ketone mixture from butanone to decanone. Effluent from the column was continuously sampled by the detector and mobility scans could be obtained throughout the chromatographic analysis providing chemical inforrmation in mobility scans orthogonal to retention time. Limits of detection were approximately I ng for measurement of positive ions and were comparable or slightly better than those for the FID. Direct comparison of calibration curves for the FAIMS and the FID was possible over four orders of magnitude with a semi-log plot. The concentration dependence of the PFAIMS mobility scans showed the dependence between ion intensity and ion clustering, evident in other mobility spectrometers and atmospheric pressure ionization technologies. Ions were identified using mass spectrometry as the protonated monomer and the proton bound dimer of the ketones. Residence time for column effluent in the PFAIMS was calculated as approximately 1 ms and a 36% increase in extra-column broadening versus the FID occurred with the PFAIMS.

  11. Computer monitoring, capture and analysis of gas/liquid chromatograph traces.

    PubMed

    Bulleid, N; Schofield, J

    1986-12-01

    The work described here is effectively the computerization of a gas/liquid chromatograph of the pen recorder type using a BBC microcomputer. The output from the g.l.c. can be captured by the computer in accordance with a series of parameters. The sampling rate can be altered, as can an averaging facility to reduce noise, and a threshold level to eliminate the storage of irrelevant and space-consuming data. The unprocessed readings are initially stored on the computer's floppy disk, then later retrieved and cut into smaller sections to allow maximum resolution for on-screen analysis. In the main analysis stage of the system all processing is shown graphically on the computer monitor at all stages. The principal steps in analysis involve the mathematical modelling and elimination of the solvent peak, the fixing of the retention time for each subsequent peak and its disentangling from any following peaks, and finally the calculation of the area under each individual peak. Several alternative methods are made available for disentangling peaks, which can be tried successively on a single peak then each printed out with comments for comparison later. All readings and results in table form and screen dumps of all trace images are available via a dot matrix printer.

  12. Evaluation of two commercial capillary columns for the enantioselective gas chromatographic separation of organophosphorus pesticides.

    PubMed

    Fidalgo-Used, Natalia; Blanco-González, Elisa; Sanz-Medel, Alfredo

    2006-12-15

    The separation of the enantiomers of 13 organophosphorus pesticides (OPPs) has been investigated by gas chromatography (GC) with flame ionisation detection (FID) using two different commercially available chiral columns, Chirasil-Val (l-valine-tert-butylamide) and CP-Chirasil-Dex CB (heptakis (2,3,6-tri-O-metil)-beta-cyclodextrin). Using the Chirasil-Val column no chiral resolution was obtained for the OPPs investigated under any tested experimental condition. The use of the CP-Chirasil-Dex CB stationary phase enabled good individual enantiomeric separation of two OPPs, ruelene and trichlorfon and partial separation of naled, chloretoxyphos, isophenphos and metamidophos. Also, the obtained chromatographic results showed that Chirasil-Dex could resolve enantiomers through the combination of different mechanism (e.g. formation of inclusion complexes and/or interactions outside the cyclodextrin cavity). Under optimised conditions, precision, linearity range and detection limits were evaluated for the enantiomers of ruelene and trichlorfon using CP-Chirasil-Dex CB column and electron capture detection (ECD). By using the GC-ECD method the enantiomers of these OPPs could be satisfactorily detected at very low concentration levels. The detection limits observed were 1.5ngmL(-1) and 11.5ngmL(-1) for the enantiomers of trichlorfon and ruelene, respectively. PMID:18970881

  13. Determination of vapor pressures for nonpolar and semipolar organic compounds from gas chromatographic retention data

    USGS Publications Warehouse

    Hinckley, D.A.; Bidleman, T.F.; Foreman, W.T.; Tuschall, J.R.

    1990-01-01

    Vapor pressures for nonpolar and moderately polar organochlorine, pyrethroid, and organophosphate insecticides, phthalate esters, and organophosphate flame retardants were determined by capillary gas chromatography (GC). Organochlorines and polycyclic aromatic hydrocarbons with known liquid-phase vapor pressures (P??L) (standard compounds) were chromatographed along with two reference compounds n-C20 (elcosane) and p,p???-DDT on a 1.0-m-long poly(dimethylsiloxane) bonded-phase (BP-1) column to determine their vapor pressures by GC (P??GC). A plot of log P??L vs log P??GC for standard compounds was made to establish a correlation between measured and literature values, and this correlation was then used to compute P??L of test compounds from their measured P??GC. P??L of seven major components of technical chlordane, endosulfan and its metabolites, ??-hexachlorocyclohexane, mirex, and two components of technical toxaphene were determined by GC. This method provides vapor pressures within a factor of 2 of average literature values for nonpolar compounds, similar to reported interlaboratory precisions of vapor pressure determinations. GC tends to overestimate vapor pressures of moderately polar compounds. ?? 1990 American Chemical Society.

  14. Rapid and sensitive gas-chromatographic determination of caffeine in blood plasma, saliva, and xanthine beverages.

    PubMed

    Teeuwen, H W; Elbers, E L; van Rossum, J M

    1991-02-01

    A gas chromatographic procedure is reported for the determination of caffeine in plasma, saliva, and xanthine beverages. Using a 75 cm column packed with OV-17, nitrogen-sensitive detection, and 1 ml samples, a suitable limit of analysis (coefficient of variation (CV) = 10.2%) of 50 ng/ml was obtained in plasma. Within-day CVs at caffeine concentrations of 0.1-0.5-2.0-7.5-15.0 micrograms/ml in plasma were 7.7-5.6-4.8-3.8-3.4%, respectively. The limit of detection, defined as the injected quantity of caffeine giving rise to a signal to noise ratio of 2, is 40 pg, corresponding to a plasma concentration of 1 ng/ml. The procedure involves addition of the internal standard 7-pentyl theophylline and alkaline extraction of the sample with dichloromethane. The method described rivals any gaschromatographic assay published so far in rapidness and accuracy. Plasma and saliva caffeine concentrations were determined in a healthy male volunteer after swallowing 400 ml of coffee. The calculated pharmacokinetic parameters, assuming complete absorption of caffeine from the G.I. tract, agree well with previously published values. PMID:1875916

  15. Headspace gas chromatographic determination of methylene chloride in decaffeinated tea and coffee, with electrolytic conductivity detection.

    PubMed

    Page, B D; Charbonneau, C F

    1984-01-01

    A headspace gas chromatographic procedure is described for the determination of methylene chloride (MC) in decaffeinated tea and coffee. The tea or coffee sample, with added methylene bromide (MB) internal standard, is equilibrated for 1.5 h at 100 degrees C in aqueous sodium sulfate before manual headspace sampling. MC and MB are separated on a Porasil A column at 160 degrees C and detected by using a Coulson electrolytic conductivity detector. For coffee and tea samples spiked at 1.3 ppm MC, as well as commercially decaffeinated teas and coffees containing up to 8 ppm MC, coefficients of variation were 10% or less. For decaffeinated teas, problems involving sample homogeneity and loss of MC before sealing the headspace vial had to be overcome. Similar problems with decaffeinated instant and ground coffees were minimal. The headspace procedure was superior to a previously reported distillation technique. MC was readily detected at 0.05 ppm. Fourteen decaffeinated teas and 15 decaffeinated coffees were analyzed; MC was detected at levels that ranged up to 15.9 and 4.0 ppm, respectively. PMID:6469909

  16. Gas chromatographic mass analysis and further pharmacological actions of Cymbopogon proximus essential oil.

    PubMed

    Al-Taweel, A M; Fawzy, G A; Perveen, S; El Tahir, K E H

    2013-09-01

    The present study reports Gas chromatographic mass analysis (GC-MS) as well as important biological activities of Cymbopogon proximus essential oil. The chemical composition of the essential oil of Cymbopogon proximus was investigated by GC-MS. Furthermore, the effects of Cymbopogon proximus essential oil on the cardiac parasympathetic ganglia in rats, the intra-tracheal pressure in guinea-pigs and on carrageenan-induced inflammation in the rats paw, were studied. The GC-MS study led to the identification of 22 components with Piperitone representing (73.81%), Elemol (9.32%), alpha-Eudesmol (5.21%) and alpha-Terpineol (3.01%) of the oils composition. The percentage protective effect of the oil on the vagus-induced bradycardia in rats was 90.1±3.1%, which represents a significant protection. As for the effect of Cymbopogon oil on bronchoconstrictors-induced increase in intra-tracheal pressure in guinea-pigs, the oil antagonized the actions of 5-HT and histamine by 80±3.7 and 93±8.3%, respectively. Pharmacological investigations using Cymbopogon oil revealed its inherent ability to possess a bronchodilator activity mediated via blockade of both histamine and serotonin receptors. It possessed a significant ganglionic blocking action and a limited anti-inflammatory activity that seemed to involve blockade of histamine and serotonin receptors in the rats' paws.

  17. Graphitic carbon nitride as high-resolution stationary phase for gas chromatographic separations.

    PubMed

    Zheng, Yunzhong; Qi, Meiling; Fu, Ruonong

    2016-07-01

    This work presents the first example of utilization of graphitic carbon nitride (g-C3N4) as stationary phase for capillary gas chromatographic (GC) separations. The statically coated g-C3N4 column showed the column efficiencies of 3760 plates/m and weak polarity. Its resolving capability and retention behaviours were investigated by using the Grob test mixture, and mixtures of diverse types of analytes, and structural and positional isomers. The results showed superior separation performance of the g-C3N4 stationary phase for some critical analytes and preferential retention for aromatic analytes. Specifically, it exhibited high-resolution capability for aromatic and aliphatic isomers such as methylnaphthalenes and dimethylnaphthalenes, phenanthrene and anthracene and alkane isomers. In addition, g-C3N4 column showed excellent thermal stability up to 280°C and good repeatability with relative standard deviation (RSD) values less than 0.09% for intra-day, below 0.23% for inter-day and in the range of 1.9-8.4% for between-column, respectively. The advantageous separation performance shows the potential of g-C3N4 and related materials as stationary phase in GC and other separation technologies.

  18. The gas-liquid chromatograph and the electron capture detection in equine drug testing.

    PubMed Central

    Blake, J. W.; Tobin, T.

    1976-01-01

    Three gas-liquid chromatographic (G.L.C.) procedures discussed have been designed around the four "esses" of detection tests--speed, sensitivity, simplicity, and specificity. These techniques are admirably applicable to the very low plasma drug levels encountered in blood testing under pre-race conditions. The methods are equally applicable to post-race testing procedures, where both blood and urine samples are tested. Drugs can only rarely be detected by the electron capture detector (E.C.D.) without a prior derivatization step, which conveys to the drug(s) high electron affinity. Because of broad applicability, two derivatizing agents, heptafluorobutyric (HFBA) and pentafluorpropionic (PFPA) anhydrides are employed. The three techniques, allowing broad coverage of various drug classes are: 1) direct derivatization of drugs to form strongly electron capturing amides and esters. 2) reductive fragmentation of drugs with lithium aluminum hydride to form alcohols, with conversion to ester derivatives. 3) oxidative fragmentation of drugs with potassium dichromate to form derivatizable groups, followed by direct derivatization. PMID:1000157

  19. Decoration of vertical graphene with aerosol nanoparticles for gas sensing

    NASA Astrophysics Data System (ADS)

    Cui, Shumao; Guo, Xiaoru; Ren, Ren; Zhou, Guihua; Chen, Junhong

    2015-08-01

    A facile method was demonstrated to decorate aerosol Ag nanoparticles onto vertical graphene surfaces using a mini-arc plasma reactor. The vertical graphene was directly grown on a sensor electrode using a plasma-enhanced chemical vapor deposition (PECVD) method. The aerosol Ag nanoparticles were synthesized by a simple vapor condensation process using a mini-arc plasma source. Then, the nanoparticles were assembled on the surface of vertical graphene through the assistance of an electric field. Based on our observation, nonagglomerated Ag nanoparticles formed in the gas phase and were assembled onto vertical graphene sheets. Nanohybrids of Ag nanoparticle-decorated vertical graphene were characterized for ammonia gas detection at room temperature. The vertical graphene served as the conductance channel, and the conductance change upon exposure to ammonia was used as the sensing signal. The sensing results show that Ag nanoparticles significantly improve the sensitivity, response time, and recovery time of the sensor.

  20. Performance of the MOMA Gas Chromatograph-Mass Spectrometer onboard the 2018 ExoMars Mission

    NASA Astrophysics Data System (ADS)

    Buch, Arnaud; Pinnick, Veronica; Szopa, Cyril; Grand, Noël; Freissinet, Caroline; Danell, Ryan; van Ameron, Friso; Arevalo, Ricardo; Brinckerhoff, William; Raulin, François; Mahaffy, Paul; Goesmann, Fred

    2015-04-01

    The Mars Organic Molecule Analyzer (MOMA) is a dual ion source linear ion trap mass spectrometer that was designed for the 2018 joint ESA-Roscosmos mission to Mars. The main scientific aim of the mission is to search for signs of extant or extinct life in the near subsurface of Mars by acquir-ing samples from as deep as 2 m below the surface. MOMA will be a key analytical tool in providing chemical (molecular) information from the solid samples, with particular focus on the characterization of organic content. The MOMA instrument, itself, is a joint venture for NASA and ESA to develop a mass spectrometer capable of analyzing samples from pyrolysis gas chromatograph (GC) as well as ambient pressure laser desorption ionization (LDI). The combination of the two analytical techniques allows for the chemical characterization of a broad range of compounds, including volatile and non-volatile species. Generally, MOMA can provide in-formation on elemental and molecular makeup, po-larity, chirality and isotopic patterns of analyte spe-cies. Here we report on the current performance of the MOMA prototype instruments, specifically the demonstration of the gas chromatography-mass spec-trometry (GC-MS) mode of operation. Both instruments have been tested separately first and have been coupled in order to test the efficiency of the future MOMA GC-MS instrument. The main objective of the second step has been to test the quantitative response of both instruments while they are coupled and to characterize the combined instrument detection limit for several compounds. A final experiment has been done in order to test the feasibility of the separation and detection of a mixture contained in a soil sample introduced in the MOMA oven.

  1. Gas chromatographic simulated distillation-mass spectrometry for the determination of the boiling point distributions of crude oils

    PubMed

    Roussis; Fitzgerald

    2000-04-01

    The coupling of gas chromatographic simulated distillation with mass spectrometry for the determination of the distillation profiles of crude oils is reported. The method provides the boiling point distributions of both weight and volume percent amounts. The weight percent distribution is obtained from the measured total ion current signal. The total ion current signal is converted to weight percent amount by calibration with a reference crude oil of a known distillation profile. Knowledge of the chemical composition of the crude oil across the boiling range permits the determination of the volume percent distribution. The long-term repeatability is equivalent to or better than the short-term repeatability of the currently available American Society for Testing and Materials (ASTM) gas chromatographic method for simulated distillation. Results obtained by the mass spectrometric method are in very good agreement with results obtained by conventional methods of physical distillation. The compositional information supplied by the method can be used to extensively characterize crude oils.

  2. Time-resolved inorganic chemical composition of fine aerosol and associated precursor gases over an urban environment in western India: Gas-aerosol equilibrium characteristics

    NASA Astrophysics Data System (ADS)

    Sudheer, A. K.; Rengarajan, R.

    2015-05-01

    Inorganic ionic constituents (Na+, NH4+, K+, Mg2+, Ca2+, Cl-, NO3- and SO42-) of PM2.5 and associated trace gases (NH3, HNO3 and HCl) were measured simultaneously by Ambient Ion Monitor - Ion Chromatograph (AIM-IC) system with a time resolution of one hour at an urban location in semi-arid region of western India during summer and winter. The average NH3, HNO3 and HCl concentrations were 11.6 ± 5.0, 2.9 ± 0.8 and 0.15 μg m-3, respectively, during winter. During summer, NH3 and HNO3 concentrations were of similar magnitude, whereas HCl concentration was less than ∼0.03 μg m-3. NH3 concentration exhibited a distinct diurnal variation during both seasons. However, HNO3 did not show a specific diurnal trend during the observation period in both seasons. The data obtained were used to study gas-aerosol equilibrium characteristics using a thermodynamic equilibrium model, ISORROPIA II. The results suggest that NH3 exists in equilibrium between measured fine-mode particle and gas phase with a systematic bias of ∼14%, whereas HCl and HNO3 deviate significantly from the modelled data. These observations have implications on thermodynamic equilibrium assumptions used for estimating various aerosol parameters such as liquid water content, pH, etc., thus causing significant bias in chemical transport model results over the study region.

  3. Cloud point extraction with surfactant derivatization as an enrichment step prior to gas chromatographic or gas chromatography-mass spectrometric analysis.

    PubMed

    Takagai, Yoshitaka; Hinze, Willie L

    2009-08-15

    Cloud point extraction (CPE) using Triton X-114 was successfully applied as an extractive preconcentration step prior to gas chromatographic-mass spectrometric analysis. No liquid chromatographic or back-extraction steps were required to remove the target analyte(s) from the surfactant-rich extractant phase. Instead a post-extraction derivatization step is employed in which the surfactant of the surfactant-rich phase is reacted with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) prior to injection into the gas chromatograph. Such derivatization of the Triton X-114 surfactant following CPE was found to provide improved chromatographic performance yielding a reasonable elution time window that is free of derivatized surfactant signals, reproducible analyte retention times, and quantitative results. Mixtures of polycyclic aromatic hydrocarbons (PAHs), herbicides, and profens were utilized to demonstrate the feasibility and performance of this approach. The retention times of six PAHs (acenaphthene, acenaphthylene, anthracene, biphenyl, dibenzofuran, and fluorene) were found to be very reproducible with relative standard deviations (RSDs) in the range of 0.5-0.8%. Quantitative gas chromatography-mass spectrometry (GC/MS) analysis of a herbicide test mixture (composed of alachlor, atrazine, butachlor, hexachlorocyclopentadiene, metolachlor, and simazine) following their CPE from spiked water samples yielded detection limits in the range of 6.6-97 ng/L (except for that of hexachlorocyclopentadiene which was 482 ng/L). The enrichment factors achieved for these herbicides ranged from 17 to 33. The recovery of the herbicides from spiked water samples ranged from 90 to 100% except for simazine and atrazine which were 50% and 74%, respectively. The BSFTA derivatization step can serve not only to derivatize the surfactant but also appropriate nonvolatile (or less volatile) analytes. An ibuprofen and flurbiprofen test mix was utilized to demonstrate this feature. The

  4. Using multidimensional gas chromatography to group secondary organic aerosol species by functionality

    NASA Astrophysics Data System (ADS)

    Flores, Rosa M.; Doskey, Paul V.

    2014-10-01

    A carbon number-functionality grid (CNFG) for a complex mixture of secondary organic aerosol (SOA) precursors and oxidation products was developed from the theoretical retention index diagram of a multidimensional gas chromatographic (GC × 2GC) analysis of a mixture of SOA precursors and derivatized oxidation products. In the GC × 2GC analysis, comprehensive separation of the complex mixture was achieved by diverting the modulated effluent from a polar primary column into 2 polar secondary columns. Column stationary phases spanned the widest range of selectivity of commercially available GC analytic columns. In general, separation of the species by the polar primary column was by the number of carbon atoms in the molecule (when the homologous series of reference compounds was selected to have molecular volumes and functionalities similar to the target analytes) and the polar secondary columns provided additional separation according to functionality. An algebraic transformation of the Abraham solvation parameter model was used to estimate linear retention indices of solutes relative to elution of a homologous series of methyl diesters on the primary and secondary columns to develop the theoretical GC × 2GC retention diagram. Retention indices of many of the oxidation products of SOA precursors were estimated for derivatized forms of the solutes. The GC stationary phases selected for the primary column [(50%-Trifluoropropyl)-methylpolysiloxane] and secondary columns (90% Cyanopropyl Polysilphenylene-siloxane and Polyethylene Glycol in a Sol-Gel matrix) provided a theoretical separation of 33 SOA precursors and 98 derivatized oxidation products into 35 groups by molecular volume and functionality. Comprehensive analysis of extracts of vapor and aerosol samples containing semivolatile SOA precursors and oxidation products, respectively, is best accomplished by (1) separating the complex mixture of the vapor and underivatized aerosol extracts with a (50

  5. Gas and aerosol wall losses in Teflon film smog chambers

    SciTech Connect

    McMurry, P.H.; Grosjean, D.

    1985-12-01

    Large smog chambers (approx.60 m/sup 3/) constructed of FEP Teflon film are frequently used to study photochemistry and aerosol formation in model chemical systems. In a previous paper a theory for aerosol wall loss rates in Teflon film smog chambers was developed; predicted particle loss rates were in good agreement with measured rates. In the present paper, measurements of wall deposition rates and the effects of wall losses on measurements of gas-to-particle conversion in smog chambers are discussed. Calculations indicate that a large fraction of the aerosol formed in several smog chamber experiments was on the chamber walls at the end of the experiment. Estimated values for particulate organic carbon yield for several precursor hydrocarbons increased by factors of 1.3-6.0 when wall deposition was taken into account. The theory is also extended to loss rates of gaseous species. Such loss rates are either limited by diffusion through a concentration boundary layer near the surface or by uptake at the surface. It is shown that for a typical 60-m/sup 3/ Teflon film smog chamber, gas loss rates are limited by surface reaction rates if mass accommodation coefficients are less than 6 x 10/sup -6/. It follows that previously reported loss rates of several gases in a chamber of this type were limited by surface reactions.

  6. [Gas chromatographic determination of the solubility coefficient for volatile anaesthetics (author's transl)].

    PubMed

    Lauven, P M; Hack, G; Stoeckel, H

    1979-03-01

    For the determination of the solubility coefficient of volatile anaesthetics in Schindler's liquid culture, modified by Karzel, a gas-chromatographic analysis with direct-injection-method was used. A well defined volume with a known concentration of the anaesthetic was added to a vessel with known volume. After equilibration the concentration of the inhalational anaesthetics was determined in the liquid at various temperatures. The solubility coefficient and the temperature coefficient were then calculated from these data. We obtained the following solubility coefficients at -4 degrees C (37 degrees): for halothane 1,07 (0,77), for enflurane 1,14 (0,70), for methoxyflurane 4,92 (3,23) and for isoflurane 1,13 (0,82). In Schindler's liquid culture modified by Karzel the values at 24 degrees (37 degrees) were: for halothane 1,33 (0,92), for enflurane 1,32 (0,87), for methoxyflurane 6,61 (4,48) and for isoflurane 1,19 (0,98). The temperature coefficient for this temperature range were in water (in Schindler's liquid culture) for halothane: -2,31 . 10(-2) K(-1) (-3,15 . 10(-2) K(-1)), for methoxyflurane: -13,0 . 10(-2) K(-1) (-16,48 . 10(-2) K(-1)), for enflurane: -3,38 . 10(-2) K(-1) (-3,46 . 10(-2) K(-1)) and for isoflurane: -2,38 . 10(-2) K(-1) (-1,62 . 10(-2) K(-1)).

  7. Gas chromatographic isolation of individual compounds from complex matrices for radiocarbon dating.

    PubMed

    Eglinton, T I; Aluwihare, L I; Bauer, J E; Druffel, E R; McNichol, A P

    1996-03-01

    This paper describes the application of a novel, practical approach for isolation of individual compounds from complex organic matrices for natural abundance radiocarbon measurement. This is achieved through the use of automated preparative capillary gas chromatography (PCGC) to separate and recover sufficient quantities of individual target compounds for (14)C analysis by accelerator mass spectrometry (AMS). We developed and tested this approach using a suite of samples (plant lipids, petroleums) whose ages spanned the (14)C time scale and which contained a variety of compound types (fatty acids, sterols, hydrocarbons). Comparison of individual compound and bulk radiocarbon signatures for the isotopically homogeneous samples studied revealed that Δ(14)C values generally agreed well (±10%). Background contamination was assessed at each stage of the isolation procedure, and incomplete solvent removal prior to combustion was the only significant source of additional carbon. Isotope fractionation was addressed through compound-specific stable carbon isotopic analyses. Fractionation of isotopes during isolation of individual compounds was minimal (<5‰ for δ(13)C), provided the entire peak was collected during PCGC. Trapping of partially coeluting peaks did cause errors, and these results highlight the importance of conducting stable carbon isotopic measurements of each trapped compound in concert with AMS for reliable radiocarbon measurements. The addition of carbon accompanying derivatization of functionalized compounds (e.g., fatty acids and sterols) prior to chromatographic separation represents a further source of potential error. This contribution can be removed using a simple isotopic mass balance approach. Based on these preliminary results, the PCGC-based approach holds promise for accurately determining (14)C ages on compounds specific to a given source within complex, heterogeneous samples.

  8. Measurement of Ethanol in Gaseous Breath Using a Miniature Gas Chromatograph

    PubMed Central

    Morey, Timothy E.; Booth, Matthew M.; Prather, Robert A.; Nixon, Sara J.; Boissoneault, Jeff; Melker, Richard J.; Goldberger, Bruce A.; Wohltjen, Hank; Dennis, Donn M.

    2011-01-01

    We designed and built a novel, miniature gas chromatograph (mGC) to use exhaled breath to estimate blood ethanol concentrations that may offer GC quality sensitivity and specificity, but with portability, reduced size, and decreased cost. We hypothesized that the mGC would accurately estimate the serum ethanol concentration using exhaled breath. Human subjects (n = 8) were dosed with ethanol employing the Widmark criteria, targeting a blood concentration of 0.08 g/dL. Serum and breath samples were collected concurrently over an hour. Ethanol concentrations in serum were measured using a CLIA-approved laboratory. Ethanol concentrations in conventional breath were assayed using a calibrated mGC or Intoxilyzer 400PA. Data were analyzed using Bland-Altman analysis using serum concentrations as a “gold standard”. For the mGC, the regression line (correlation coefficient), bias, and 95% limits of agreement were y = 1.013x − 0.009 (r = 0.91), −0.008 g/dL, and −0.031 to 0.016 g/dL, respectively, for 30 specimens. For the Intoxilyzer 400PA, the regression line (correlation coefficient), bias, and 95% limits of agreement were y = 0.599x + 0.008 (r = 0.86), −0.024 g/dL, and −0.049 to 0.002 g/dL, respectively, for 71 specimens with a large magnitude effect. We concluded that the mGC, using exhaled breath, performed well to estimate the serum ethanol concentrations. PMID:21439148

  9. Gas chromatographic quantitative analysis of methanol in wine: operative conditions, optimization and calibration model choice.

    PubMed

    Caruso, Rosario; Gambino, Grazia Laura; Scordino, Monica; Sabatino, Leonardo; Traulo, Pasqualino; Gagliano, Giacomo

    2011-12-01

    The influence of the wine distillation process on methanol content has been determined by quantitative analysis using gas chromatographic flame ionization (GC-FID) detection. A comparative study between direct injection of diluted wine and injection of distilled wine was performed. The distillation process does not affect methanol quantification in wines in proportions higher than 10%. While quantification performed on distilled samples gives more reliable results, a screening method for wine injection after a 1:5 water dilution could be employed. The proposed technique was found to be a compromise between the time consuming distillation process and direct wine injection. In the studied calibration range, the stability of the volatile compounds in the reference solution is concentration-dependent. The stability is higher in the less concentrated reference solution. To shorten the operation time, a stronger temperature ramp and carrier flow rate was employed. With these conditions, helium consumption and column thermal stress were increased. However, detection limits, calibration limits, and analytical method performances are not affected substantially by changing from normal to forced GC conditions. Statistical data evaluation were made using both ordinary (OLS) and bivariate least squares (BLS) calibration models. Further confirmation was obtained that limit of detection (LOD) values, calculated according to the 3sigma approach, are lower than the respective Hubaux-Vos (H-V) calculation method. H-V LOD depends upon background noise, calibration parameters and the number of reference standard solutions employed in producing the calibration curve. These remarks are confirmed by both calibration models used. PMID:22312744

  10. Effect of Tropospheric Aerosols in Satellite-Based Trace Gas Retrieval

    NASA Technical Reports Server (NTRS)

    Krotkov, Nickolay; Torres, Omar; Yang, Kai; Vassilkov, Alexander

    2011-01-01

    Scattering and absorption by tropospheric aerosol particles have an effect on the airmass factor (AMF), a fundamental quantity for trace gas concentration retrieval by inversion of satellite measurements. The interference effect depends on the aerosols micro-physical and optical properties as well as the relative distribution of the tropospheric trace gas and aerosol load. Quantifying the aerosol impact on trace gas retrieval requires a sensitivity study using radiative transfer calculations. In this presentation we will describe a recently initiated effort to characterize the aerosol-related error in trace gas retrievals when the presence of aerosol particles is not accounted in the inversion procedure. A general description of the project will be presented and preliminary results on aerosol effects on SO2 retrieved concentrations will be discussed.

  11. The Application of Chemical Derivatization in Forensic Drug Chemistry for Gas and High-Performance Liquid Chromatographic Methods of Analysis.

    PubMed

    Moore, J M

    1990-12-01

    The analyses of solid-dosage forensic drug samples can be enhanced by chemical derivatization followed by gas chromatography or high-performance liquid chromatography. Using these techniques permits improved detection and chromatography of some illicit drugs and their manufacturing by-products. This review focuses on the use of chemical derivatization in conjunction with gas chromatography-flame ionization detection, gas chromatography-electron capture detection, gas chromatography-mass spectrometry, high-performance liquid chromatography-ultraviolet detection and high-performance liquid chromatography-fluorescence detection in the analysis of illicit drug samples. These drugs include the amphetamines, barbiturates, cannabis, fentanyls, opium, and hallucinogens. Discussion on sensitivity enhancement and determination of enantiomeric composition using gas chromatography and high-performance liquid chromatography is included. An entire section is devoted to the chemical derivatization and chromatographic analyses of manufacturing by-products found in illicit amphetamine and methamphetamine, heroin, and cocaine samples. This review also includes a section that describes practical elements and experimental design associated with chemical derivatization-chromatographic analyses..

  12. Capillary gas chromatographic assay of camphor and m-cresol in dermatological creams.

    PubMed

    Mirza, T; Tan, H S

    1998-09-01

    Camphor and m-cresol mixtures are used in antiseptic and anti-itching creams. No compendial method exists for these preparations. This paper reports a capillary gas chromatographic method using FID detection with 2,6-di-tert-butyl-4-methylphenol as internal standard on a 30 m x 0.32 mm Supelcowax -10 column (0.25 micron film) with helium as carrier gas. Ramped temperature programming was applied. The method allows simultaneous quantitation of camphor and m-cresol in the presence of o- and p-cresols, calamine and zinc oxide. Overall percent recoveries (+/- SD, n = 9) of camphor, o-, p- and m-cresol from spiked placebo creams, at a labeled amount of 10 (w/w)% were 96.9 +/- 0.6, 98.2 +/- 0.6, 99.2 +/- 0.5 and 101.0 +/- 0.9%, respectively, and at a labeled amount of 1% were 96.7 +/- 0.6, 97.8 +/- 0.9, 97.8 +/- 0.6, and 100.3 +/- 1.0%, respectively. The recovery studies were carried out at +/- 30% of the labeled amounts. Linear peak area or height ratios were obtained (r > 0.999) for camphor, o-, p- and m-cresol covering a concentration range of 10-200% of the labeled amount. Linearity (r > 0.999) was also obtained for m-cresol when the relative concentration of o- and p-cresol was varied from 5 to 100% of the m-cresol concentration. The resolution between the 'critical pair' of p- and m-cresol was > or = 1.1. The limit of quantitation was 23 pg for m-cresol and 9.3 pg for camphor using an injection split of 1:50. The repeatability (%RSD) for all compounds were < 2% for peak area and < 1.4% for peak height ratios. System suitability and robustness of the method were established. The method was successively applied to the assay of available commercial products and allows assay of camphor and the three cresol isomers. PMID:9800662

  13. Development and evaluation of a gas chromatographic method for the determination of triazine herbicides in natural water samples

    USGS Publications Warehouse

    Steinheimer, T.R.; Brooks, M.G.

    1984-01-01

    A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0.1 ??g/L in a 1-litre sample. Three different natural water samples were used for error analysis via evaluation of recovery efficiencies and estimation of overall method precision. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0. 1 mu g/L in a 1-litre sample. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.

  14. The Sample Analysis At Mars Gas Chromatograph (sam-gc) Ability To Detect Organic Molecules At The Mars Surface

    NASA Astrophysics Data System (ADS)

    Francois, Pascaline; Coll, P.; Szopa, C.; Buch, A.; Sternberg, R.; Cabane, M.; Mahaffy, P.

    2012-10-01

    The environmental conditions on Mars might have been favorable for the emergence of Life. The search for clues of a prebiotic chemistry or a biological activity represents one of the main objectives of the Mars Science Laboratory (MSL) mission. The Sample Analysis at Mars Gas Chromatograph (SAM-GC), aboard Curiosity rover, is dedicated to organic molecules research in atmospheric and solid samples. This instrument is constituted of six complementary chromatographic columns which have been selected to provide a broad range of separation and detection capability (volatile, refractory and chiral molecules). In order to treat and interpret the SAM-GC in situ results, it is necessary: (1) to determine the instrument ability to detect targets molecules under the instrument operating conditions and (2) to create a chromatographic and mass spectra data base to help their identification. With this aim we first selected molecules which might be analyzed with SAM-GC using the following criteria: (1) abundance at the Mars surface (2) astrobiological interest, (3) formation during the sample preparation. Then we characterized these target molecules on a laboratory gas chromatograph mass spectrometer (GC-MS) using a Chirasildex (30m x 0,25mm x 0,25µm) column dedicated to the enantiomeric separation and a CLP (30m x 0,25mm x 0,25µm) generalist columns which will be probably the first to be used on Mars. In a second step, we will use a SAM-GC mock-up to mimick the environmental conditions (pressure and temperature) inside Curiosity rover and study its variation impact on analyzes. Finally, we will present a study carried out on a Martian analogs, as Atacama samples.

  15. Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

    NASA Technical Reports Server (NTRS)

    Huz, Kateryna

    2014-01-01

    RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better

  16. Peak tailoring concept in gas chromatographic analysis of volatile organic pollutants in the atmosphere.

    PubMed

    Wang, Chieh-Heng; Chang, Chih-Chung; Wang, Jia-Lin

    2005-09-16

    An automated gas chromatographic system aiming at performing unattended analysis of volatile organic compounds (VOCs) was developed in laboratory. To encompass VOCs of a wide range of volatility, two different designs of enrichment and separation methods were adopted and compared with performance in analyzing ozone precursors of C3-C12. In the dual-trap dual-column design, lower boiling species (C3-C6) are enriched and separated by one set of trap and column (porous layer open tubular (PLOT)), whereas the enrichment and separation for the higher boiling species (C6-C12) are performed by the other set (wall-coated open tubular (WCOT)). Undesired peaks also inevitably appear on both chromatograms often causing annoyances. To reduce complexity of both the apparatus and the resulting chromatograms, the heart-cut technique was adopted as a base for developing a system, which only uses one trap and one flame ionization detector for constructing two-dimensional GC with PLOT and DB-1. Methods were developed to allow the auxiliary flow pressure in the heart-cut device to be programmed to create dual effects, which not only can perform regular heart-cut actions but can also temporally hold up species in the precolumn for prescribed time intervals. Because it is characteristic for PLOT chromatograms to have reproducible blank retention time windows, segments of a DB-1 trace are produced by the auxiliary flow program aligning perfectly in time with the gaps of the PLOT trace. Subsequently, the two column flows are merged and channeled into single flame ionization detector to produce a very condensed "tailored" chromatogram which is equivalent to overlaying a PLOT and a DB-1 chromatogram on top of each other, except that no peaks are overlapped. This innovative "peak tailoring" concept based on the heart-cut technique is simple in design, easy to build, and extremely rugged for long-term continuous operation as fewer moving parts are involved, which is beneficial for deploying

  17. Comparison of two gas-liquid chromatograph columns for the analysis of fatty acids in ruminant meat.

    PubMed

    Alves, Susana P; Bessa, Rui J B

    2009-06-26

    Two gas-liquid chromatograph capillary columns for the analysis of fatty acids (FA) in ruminant fat are compared. Those columns are the CP-Sil 88 of 100 m long with a highly polar stationary phase and the Omegawax 250 of 30 m long with a stationary phase of intermediate polarity. Fatty acid methyl ester (FAME) patterns of branched-chain, cis and trans octadecenoate isomers, as well as conjugated and non-conjugated 18:2 and 18:3 isomers are fairly different between columns, even though most of the FAME could be separated on either column. However, the CP-Sil 88 showed better resolution of 18:1 isomers than Omegawax 250. The analysis of 96 samples of ruminant meat fat in both chromatographic systems showed that averages obtained for total FA content and for most of the individual FA did not differ between columns. Moreover, regression analysis of Omegawax and CP-Sil 88 data is highly correlated. Quantitative differences between chromatographic systems were detected for samples containing more than 66 mg fatty acids per gram of muscle dry matter.

  18. Sensitive glow discharge ion source for aerosol and gas analysis

    DOEpatents

    Reilly, Peter T. A.

    2007-08-14

    A high sensitivity glow discharge ion source system for analyzing particles includes an aerodynamic lens having a plurality of constrictions for receiving an aerosol including at least one analyte particle in a carrier gas and focusing the analyte particles into a collimated particle beam. A separator separates the carrier gas from the analyte particle beam, wherein the analyte particle beam or vapors derived from the analyte particle beam are selectively transmitted out of from the separator. A glow discharge ionization source includes a discharge chamber having an entrance orifice for receiving the analyte particle beam or analyte vapors, and a target electrode and discharge electrode therein. An electric field applied between the target electrode and discharge electrode generates an analyte ion stream from the analyte vapors, which is directed out of the discharge chamber through an exit orifice, such as to a mass spectrometer. High analyte sensitivity is obtained by pumping the discharge chamber exclusively through the exit orifice and the entrance orifice.

  19. Gas chromatographic/mass spectrometric analyses of unknown analytical response in imported Fava beans: 4-chloro-6-methoxyindole.

    PubMed

    Petzinger, G; Barry, T L; Roach, J A; Musser, S M; Sphon, J

    1995-01-01

    A halogenated unidentified analytical response (UAR) was encountered in a number of imported Fava bean samples during the Food and Drug Administration's routine pesticide-monitoring program. Gas chromatographic/mass spectrometric (GC/MS) analyses identified the halogenated component as 4-chloro-6-methoxyindole, a naturally occurring promutagen in Fava beans that has been linked to incidents of gastric cancer. Data from electron impact, positive and negative chemical ionization, collision-induced dissociation, and deuteration studies of this compound are presented, along with GC retention time data.

  20. Gas chromatographic/mass spectrometric analyses of unknown analytical response in imported Fava beans: 4-chloro-6-methoxyindole.

    PubMed

    Petzinger, G; Barry, T L; Roach, J A; Musser, S M; Sphon, J

    1995-01-01

    A halogenated unidentified analytical response (UAR) was encountered in a number of imported Fava bean samples during the Food and Drug Administration's routine pesticide-monitoring program. Gas chromatographic/mass spectrometric (GC/MS) analyses identified the halogenated component as 4-chloro-6-methoxyindole, a naturally occurring promutagen in Fava beans that has been linked to incidents of gastric cancer. Data from electron impact, positive and negative chemical ionization, collision-induced dissociation, and deuteration studies of this compound are presented, along with GC retention time data. PMID:7756907

  1. Preliminary results of investigations into the use of artificial neural networks for discriminating gas chromatograph mass spectra of remote samples

    NASA Technical Reports Server (NTRS)

    Geller, Harold A.; Norris, Eugene; Warnock, Archibald, III

    1991-01-01

    Neural networks trained using mass spectra data from the National Institute of Standards and Technology (NIST) are studied. The investigations also included sample data from the gas chromatograph mass spectrometer (GCMS) instrument aboard the Viking Lander, obtained from the National Space Science Data Center. The work performed to data and the preliminary results from the training and testing of neural networks are described. These preliminary results are presented for the purpose of determining the viability of applying artificial neural networks in discriminating mass spectra samples from remote instrumentation such as the Mars Rover Sample Return Mission and the Cassini Probe.

  2. In situ derivatization and hollow fiber membrane microextraction for gas chromatographic determination of haloacetic acids in water.

    PubMed

    Varanusupakul, Pakorn; Vora-Adisak, Narongchai; Pulpoka, Bancha

    2007-08-13

    An alternative method for gas chromatographic determination of haloacetic acids (HAAs) in water using direct derivatization followed by hollow fiber membrane liquid-phase microextraction (HF-LPME) has been developed. The method has improved the sample preparation step according to the conventional US EPA Method 552.2 by combining the derivatization and the extraction into one step prior to determination by gas chromatography electron captured detector (GC-ECD). The HAAs were derivatized with acidic methanol into their methyl esters and simultaneously extracted with supported liquid hollow fiber membrane in headspace mode. The derivatization was attempted directly in water sample without sample evaporation. The HF-LPME was performed using 1-octanol as the extracting solvent at 55 degrees C for 60 min with 20% Na2SO4. The linear calibration curves were observed for the concentrations ranging from 1 to 300 microg L(-1) with the correlation coefficients (R2) being greater than 0.99. The method detection limits of most analytes were below 1 microg L(-1) except DCAA and MCAA that were 2 and 18 microg L(-1), respectively. The recoveries from spiked concentration ranged from 97 to 109% with %R.S.D. less than 12%. The method was applied for determination of HAAs in drinking water and tap water samples. The method offers an easy one step high sample throughput sample preparation for gas chromatographic determination of haloacetic acids as well as other contaminants in water. PMID:17693310

  3. Gas uptake and chemical aging of semisolid organic aerosol particles.

    PubMed

    Shiraiwa, Manabu; Ammann, Markus; Koop, Thomas; Pöschl, Ulrich

    2011-07-01

    Organic substances can adopt an amorphous solid or semisolid state, influencing the rate of heterogeneous reactions and multiphase processes in atmospheric aerosols. Here we demonstrate how molecular diffusion in the condensed phase affects the gas uptake and chemical transformation of semisolid organic particles. Flow tube experiments show that the ozone uptake and oxidative aging of amorphous protein is kinetically limited by bulk diffusion. The reactive gas uptake exhibits a pronounced increase with relative humidity, which can be explained by a decrease of viscosity and increase of diffusivity due to hygroscopic water uptake transforming the amorphous organic matrix from a glassy to a semisolid state (moisture-induced phase transition). The reaction rate depends on the condensed phase diffusion coefficients of both the oxidant and the organic reactant molecules, which can be described by a kinetic multilayer flux model but not by the traditional resistor model approach of multiphase chemistry. The chemical lifetime of reactive compounds in atmospheric particles can increase from seconds to days as the rate of diffusion in semisolid phases can decrease by multiple orders of magnitude in response to low temperature or low relative humidity. The findings demonstrate that the occurrence and properties of amorphous semisolid phases challenge traditional views and require advanced formalisms for the description of organic particle formation and transformation in atmospheric models of aerosol effects on air quality, public health, and climate.

  4. Development of an Internet accessible software: optics and spectroscopy of gas-aerosol media

    NASA Astrophysics Data System (ADS)

    Voitsekhovskaya, O. K.; Kashirskii, D. E.; Egorov, O. V.

    2015-11-01

    A description of an Internet accessible software «Optics and spectroscopy of gas-aerosol media» is represented. The new software is focused on research in the field of direct and inverse problems of optics and spectroscopy of gas-aerosol media.

  5. A low thermal mass fast gas chromatograph and its implementation in fast gas chromatography mass spectrometry with supersonic molecular beams.

    PubMed

    Fialkov, Alexander B; Moragn, Mati; Amirav, Aviv

    2011-12-30

    A new type of low thermal mass (LTM) fast gas chromatograph (GC) was designed and operated in combination with gas chromatography mass spectrometry (GC-MS) with supersonic molecular beams (SMB), including GC-MS-MS with SMB, thereby providing a novel combination with unique capabilities. The LTM fast GC is based on a short capillary column inserted inside a stainless steel tube that is resistively heated. It is located and mounted outside the standard GC oven on its available top detector port, while the capillary column is connected as usual to the standard GC injector and supersonic molecular beam interface transfer line. This new type of fast GC-MS with SMB enables less than 1 min full range temperature programming and cooling down analysis cycle time. The operation of the fast GC-MS with SMB was explored and 1 min full analysis cycle time of a mixture of 16 hydrocarbons in the C(10)H(22) up to C(44)H(90) range was achieved. The use of 35 mL/min high column flow rate enabled the elution of C(44)H(90) in less than 45 s while the SMB interface enabled splitless acceptance of this high flow rate and the provision of dominant molecular ions. A novel compound 9-benzylazidanthracene was analyzed for its purity and a synthetic chemistry process was monitored for the optimization of the chemical reaction yield. Biodiesel was analyzed in jet fuel (by both GC-MS and GC-MS-MS) in under 1 min as 5 ppm fatty acid methyl esters. Authentic iprodion and cypermethrin pesticides were analyzed in grapes extract in both full scan mode and fast GC-MS-MS mode in under 1 min cycle time and explosive mixture including TATP, TNT and RDX was analyzed in under 1 min combined with exhibiting dominant molecular ion for TATP. Fast GC-MS with SMB is based on trading GC separation for speed of analysis while enhancing the separation power of the MS via the enhancement of the molecular ion in the electron ionization of cold molecules in the SMB. This paper further discusses several features of

  6. Measurement of the emission rate of an aerosol source--comparison of aerosol and gas transport coefficients.

    PubMed

    Bémer, D; Callé, S; Godinot, S; Régnier, R; Dessagne, J M

    2000-12-01

    A measuring method of the emission rate of an atmospheric pollutant source, based on the use of a tracer gas (helium) and developed in the case of a gaseous source, was tested for an aerosol source. The influence of both particle sedimentation and wall depositions was studied. The transport coefficients of the tracer gas and of alumina particles of various particle sizes (MMAD from 8 to 36 microns) were measured on a vertical axis close to the source, in a 71 m3 room swept by a piston flow. The measurements clearly demonstrated the predominant influence of sedimentation in the case of particles with aerodynamic diameters greater than 10 microns. Particle wall deposition was determined by measuring the gas and particle concentration decay in the ventilated room. To do this, a new tracing method using a fluorescent aerosol was developed. The measured aerosol deposition rates are much higher than those calculated from the formula of Corner for a cubical volume. Aerosol sedimentation and wall deposition are two phenomena limiting the use of a tracer gas to measure the aerosol emission rate. The chemical substances and materials used in work premises are likely to be released into the atmosphere and lead to the formation of pollutants. These emissions stem from either physical or chemical processes (evaporation of a solvent) or from mechanical processes (dispersion of oil droplets at the source of mists).

  7. Measurement of dissolved H2, O2, and CO2 in groundwater using passive samplers for gas chromatographic analyses.

    PubMed

    Spalding, B P; Watson, D B

    2006-12-15

    A simple in-situ passive dissolved gas groundwater sampler, comprised of a short length of silicone tubing attached to a gastight or other syringe, was adapted and tested for in-situ collection of equilibrium gas samples. Sampler retrieval after several days of immersion in groundwater allowed the direct injection of the sample onto a gas chromatograph (GC), simplifying field collection and sample handling over the commonly used "bubble stripping" method for H2 analyses. A GC was modified by sequencing a thermal conductivity (TC) detector followed by a reductive gas (RG) detector so that linear calibration of H2 over the range 0.2-200,000 ppmv was attained using a 0.5-mL gas sample; inclusion of the TC detector allowed the simultaneous quantification of other fixed gases (O2, CO2, He, and Ne) to which the RG detector was not responsive. Uptake kinetics for H2 and He indicated that the passive sampler reached equilibrium within 12 h of immersion in water. Field testing of these passive samplers revealed unusually large equilibrium gas-phase H2 concentrations in groundwater, ranging from 0.1 to 13.9%, by volume, in 11 monitoring wells surrounding four former radiological wastewater disposal ponds at the Y-12 plant in Oak Ridge, Tennessee.

  8. Solid phase micro extraction - A new technique coupled with gas chromatograph for chloroethene analysis from aqueous samples

    SciTech Connect

    Xu, N.; Sewell, G.W.

    1996-10-01

    Once the chloroethenes (tetrachloroethene and trichloroethene) contamination occurs in the subsurface environment, they tend to retain and form a Pollution plum in the aquifer because of their recalcitrance to aerobic oxidation. Currently, the most promising bioremediation method for chlorinated compounds is through anaerobic reductive biotransformation, in which each chlorine is replaced by a hydrogen. To study the biodegradation process, it is essential to monitor tetrachloroethene and its degradation daughter products frequently. An analytical method has been modified for chloroethene analysis by gas chromatography. Solid Phase Micro Extraction technique has been used to extract aqueous sample onto a fiber and then to desorb the sample directly into a gas chromatograph injection port. The total run time is less than 17 minutes.

  9. Gas-chromatographic micro-scale procedure for theophylline, with use of a nitrogen-sensitive detector.

    PubMed

    Least, C J; Johnson, G F; Solomon, H M

    1976-06-01

    We report a micro-scale procedure for determination of theophylline by use of gas chromatography with nitrogen-sensitive detection. The procedure requires only 10 mul of serum, plasma, or saliva. This sample size makes the determination especially appropriate for monitoring in a pediatric population. With the sample volume used, background interference is equivalent to about 0.1 mg/liter and 0.5 mg of theophylline per liter can easily be measured. The new method correlates well with our earlier flame ionization gas-chromatographic procedure that required 1 ml of sample [Clin. Chem. 21, 1038 (1975)]. The selectiviey of the nitrogen detector allows a simplified extraction procedure. Between-run precision (CV) is 2.8% at a theophylline concentration of 14.8 mg/liter.

  10. Micro-scale extractive alkylation procedure for the gas-chromatographic measurement of theophylline in serum and saliva, with use of a nitrogen detector.

    PubMed

    Joern, W A

    1978-09-01

    In this 10-min gas-chromatographic assay for theophylline, a 25-microliter portion of serum or saliva sample, 100 microliter of extraction reagent, and 1.0 ml of solvent were mixed, the solvent separated and evaporated, and an aliquot of the reconstituted extract injected into the gas chromatograph. At a concentration of 11 mg/liter, within-run precision (CV) was 3.6% and run-to-run 2.9%. At 22 mg/liter, within-run precision was 2.8%. Concentration and instrument response are linearly related between 2 and 40 mg/liter. The limit of detection was 0.4 mg/liter. Results correlated well (r = 0.98) with those by another micro-scale gas-chromatographic procedure. Analytical recovery was estimated to exceed 90%, and no interferences from other xanthines or related drugs were observed.

  11. Stratospheric Aerosol and Gas Experiment (SAGE) II and III Aerosol Extinction Measurements in the Arctic Middle and Upper Troposphere

    NASA Technical Reports Server (NTRS)

    Treffeisen, R. E.; Thomason, L. W.; Strom, J.; Herber, A. B.; Burton, S. P.; Yamanouchi, T.

    2006-01-01

    In recent years, substantial effort has been expended toward understanding the impact of tropospheric aerosols on Arctic climate and chemistry. A significant part of this effort has been the collection and documentation of extensive aerosol physical and optical property data sets. However, the data sets present significant interpretive challenges because of the diverse nature of these measurements. Among the longest continuous records is that by the spaceborne Stratospheric Aerosol and Gas Experiment (SAGE) II. Although SAGE tropospheric measurements are restricted to the middle and upper troposphere, they may be able to provide significant insight into the nature and variability of tropospheric aerosol, particularly when combined with ground and airborne observations. This paper demonstrates the capacity of aerosol products from SAGE II and its follow-on experiment SAGE III to describe the temporal and vertical variations of Arctic aerosol characteristics. We find that the measurements from both instruments are consistent enough to be combined. Using this combined data set, we detect a clear annual cycle in the aerosol extinction for the middle and upper Arctic troposphere.

  12. Classification of gasoline by octane number and light gas condensate fractions by origin with using dielectric or gas-chromatographic data and chemometrics tools.

    PubMed

    Rudnev, Vasiliy A; Boichenko, Alexander P; Karnozhytskiy, Pavel V

    2011-05-15

    The approach for classification of gasoline by octane number and light gas condensate fractions by origin with using dielectric permeability data has been proposed and compared with classification of same samples on the basis of gas-chromatographic data. The precision of dielectric permeability measurements was investigated by using ANOVA. The relative standard deviation of dielectric permeability was in the range from 0.3 to 0.5% for the range of dielectric permeability from 1.8 to 4.4. The application of exploratory chemometrics tools (cluster analysis and principal component analysis) allow to explicitly differentiate the gasoline and light gas condensate fractions into groups of samples related to specific octane number or origin. The neural networks allow to perfectly classifying the gasoline and light gas condensate fractions. PMID:21482310

  13. Classification of gasoline by octane number and light gas condensate fractions by origin with using dielectric or gas-chromatographic data and chemometrics tools.

    PubMed

    Rudnev, Vasiliy A; Boichenko, Alexander P; Karnozhytskiy, Pavel V

    2011-05-15

    The approach for classification of gasoline by octane number and light gas condensate fractions by origin with using dielectric permeability data has been proposed and compared with classification of same samples on the basis of gas-chromatographic data. The precision of dielectric permeability measurements was investigated by using ANOVA. The relative standard deviation of dielectric permeability was in the range from 0.3 to 0.5% for the range of dielectric permeability from 1.8 to 4.4. The application of exploratory chemometrics tools (cluster analysis and principal component analysis) allow to explicitly differentiate the gasoline and light gas condensate fractions into groups of samples related to specific octane number or origin. The neural networks allow to perfectly classifying the gasoline and light gas condensate fractions.

  14. Gas-phase removal of biofilms from various surfaces using carbon dioxide aerosols.

    PubMed

    Cha, Minju; Hong, Seongkyeol; Kang, Min-Yeong; Lee, Jin-Won; Jang, Jaesung

    2012-01-01

    The present study evaluated the removal of Escherichia coli XL1-blue biofilms using periodic jets of carbon dioxide aerosols (a mixture of solid and gaseous CO(2)) with nitrogen gas. The aerosols were generated by the adiabatic expansion of high-pressure CO(2) gas through a nozzle and used to remove air-dried biofilms. The areas of the biofilms were measured from scanning electron micrographs before and after applying the aerosols. The removal efficiency of the aerosol treatment was measured with various air-drying times of the biofilms before the treatment, surface materials, and durations of CO(2) aerosols in each 8-s aerosol-nitrogen cleaning cycle. Nearly 100% of the fresh biofilms were removed from the various surfaces very reliably within 90 s. This technique can be useful for removing unsaturated biofilms on solid surfaces and has potential applications for cleaning bio-contaminated surfaces.

  15. Evaluation of the retention pattern on ionic liquid columns for gas chromatographic analyses of fatty acid methyl esters.

    PubMed

    Lin, Chen-Chen; Wasta, Ziar; Mjøs, Svein A

    2014-07-11

    Fatty acid methyl esters from marine sources were analyzed by gas chromatography-mass spectrometry on three ionic liquid columns, SLB-IL61, SLB-IL82 and SLB-IL100 (Supelco). Retention indices (equivalent chain lengths) are reported for more than 100 compounds and the overlap patterns are evaluated from these data. The influence of chromatographic conditions on the retention indices of unsaturated fatty acid methyl esters is also evaluated. Compared to typical alternative phases the retention patterns on all three columns are highly dependent on the conditions. The SLB-IL61 phase had overlaps between nutritionally important fatty acids that could not be resolved by changing the chromatographic conditions. This column is therefore regarded as unsuitable for clinical and nutritional studies of the fatty acid composition, but similar overlaps may be avoided on IL82 and IL100. On all three columns double bonds close to the carboxyl group in the analytes contribute with limited retention, which makes it challenging to predict the retention of polyunsaturated fatty acid methyl esters. PMID:24873965

  16. Atmospheric aerosol and gas sensing using Scheimpflug lidar

    NASA Astrophysics Data System (ADS)

    Mei, Liang; Brydegaard, Mikkel

    2015-04-01

    This work presents a new lidar technique for atmospheric remote sensing based on Scheimpflug principle, which describes the relationship between nonparallel image- and object-planes[1]. When a laser beam is transmitted into the atmosphere, the implication is that the backscattering echo of the entire illuminated probe volume can be in focus simultaneously without diminishing the aperture. The range-resolved backscattering echo can be retrieved by using a tilted line scan or two-dimensional CCD/CMOS camera. Rather than employing nanosecond-pulsed lasers, cascade detectors, and MHz signal sampling, all of high cost and complexity, we have developed a robust and inexpensive atmospheric lidar system based on compact laser diodes and array detectors. We present initial applications of the Scheimpflug lidar for atmospheric aerosol monitoring in bright sunlight, with a 3 W, 808 nm CW laser diode. Kilohertz sampling rates are also achieved with applications for wind speed and entomology [2]. Further, a proof-of-principle demonstration of differential absorption lidar (DIAL) based on the Scheimpflug lidar technique is presented [3]. By utilizing a 30 mW narrow band CW laser diode emitting at around 760 nm, the detailed shape of an oxygen absorption line can be resolved remotely with an integration time of 6 s and measurement cycle of 1 minute during night time. The promising results demonstrated in this work show potential for the Scheimpflug lidar technique for remote atmospheric aerosol and gas sensing, and renews hope for robust and realistic instrumentation for atmospheric lidar sensing. [1] F. Blais, "Review of 20 years of range sensor development," Journal of Electronic Imaging, vol. 13, pp. 231-243, Jan 2004. [2] M. Brydegaard, A. Gebru, and S. Svanberg, "Super resolution laser radar with blinking atmospheric particles - application to interacting flying insects " Progress In Electromagnetics Research, vol. 147, pp. 141-151, 2014. [3] L. Mei and M. Brydegaard

  17. Simultaneous gas-chromatographic analysis for diazepam and its major metabolite, desmethyldiazepam, with use of double internal standardization.

    PubMed

    Greenblatt, D J

    1978-10-01

    Electron-capture gas-liquid chromatography was used for simultaneous quantitation of plasma diazepam (I) and its major metabolite, desmethyldiazepam(II). Because concentrations of I can greatly exceed those of II after single doses of I, two benzodiazepine-analog internal standards were added to all samples, thereby allowing reliable quantitation of high concentrations of I and low concentrations of II. After extraction at neutral pH with benzene (containing isoamyl alcohol), the organic extract is evaporated and the residue is reconstituted in a small volume of solvent and chromatographed on a 3% OV-17 column. The sensitivity limits are 2 to 3 ng of I or II per milliliter of original sample, with a CV for identical samples of less than 5%. The applicability of the method to single-dose pharmacokinetic studies of I in humans is illustrated.

  18. The use of canisters/GC-MS and a portable gas chromatograph to characterize emissions from an air stripper

    SciTech Connect

    Figueroa, C.M.; Bennett, J.L.

    1994-12-31

    Demonstrating and maintaining removal efficiencies for various volatile organic compounds (VOCs) in an air stripper/carbon adsorption system would ideally be done through continuous real-time monitoring. However, especially for state funded cleanup operations, cost considerations and timeliness of decisions become the overriding factors. Method TO-14, consisting of whole air samples obtained in stainless steel canisters shipped for GC-MS analysis, is the conventional method to speciate and quantitate VOCs at the sub-parts per billion levels found in the carbon adsorption system outlet. Unfortunately, method TO-14 does not provide real time information, and can be expensive. This paper summarizes the results obtained from using both method TO-14 and a portable gas chromatograph with a photoionization detector to characterize emissions from an air-stripper/carbon adsorption system. Field experience indicates that a combination of both methods can achieved the desired results at a reasonable cost.

  19. [The preparation procedure of tests for the gas chromatographic determination of fat acids without preliminary extraction of lipids].

    PubMed

    Aripovskiĭ, A V; Kolesnik, P O; Vezhdel, M I; Titov, V N

    2012-01-01

    The enhancement of the procedure of quantitative gas chromatographic determination of fit acids in biologic liquids samples is proposed. Instead of the conventional Folch procedure of extraction of lipids with subsequent ablution, concentration and methylation of extracts the direct saponification and methylation of vacuum dried liquid samples (50-200 mkl) can be applied. To compare the effectiveness of the proposed and conventional procedures both of them had been applied to evaluate how converge the results of determination of composition of fat acids in whole blood, blood plasma, packed red blood cells, homogenates of hepatic and muscular tissues. The proposed procedure is applied to determine the characteristics of fat acids composition inpatients with ischemic heart disease.

  20. Cyclotriveratrylene as a new-type stationary phase for gas chromatographic separations of halogenated compounds and isomers.

    PubMed

    Lv, Qing; Zhang, Qing; Qi, Meiling; Bai, Hua; Ma, Qiang; Meng, Xianshuang; Fu, Ruonong

    2015-07-24

    Cyclotriveratrylene (CTV) is reported here for the first time as stationary phase for capillary gas chromatographic (GC) separations. CTV stationary phase showed weak polarity comparable to the conventional 5% phenyl polysiloxane stationary phase but exhibited different retention behaviours and higher resolution for some of the indicated analytes. Most importantly, CTV stationary phase exhibited preferential selectivity for halogenated compounds, positional and geometrical isomers. Effect of column temperature on retention and thermal stability of CTV column were also investigated. Moreover, CTV capillary column showed good repeatability in terms of run-to-run, day-to-day and column-to-column. The unique physicochemical features and efficient separation ability for analytes of close properties show the potential of CTV as a new-type stationary phase in GC as well as separation science.

  1. Demonstration/field study of new designs of automated gas chromatographs in Connecticut and other locations, 1992. Final report

    SciTech Connect

    Holdren, M.W.; Smith, D.L.; Pollack, A.J.; Pate, A.D.

    1993-02-01

    The objectives of the study were to install, test and demonstrate two automated gas chromatographic (GC) systems to state and regional EPA groups. The Dynatherm/Hewlett Packard GC system was designed for the measurement of the 41 toxic compounds listed in EPA's Compendium of Methods for Method TO-14. The second system was a Perkin Elmer GC configured for the analysis of the 55 ozone precursor compounds identified in the EPA Technical Assistance Document No. EPA/600-8-91/215. Both GC systems performed well during the field evaluations with data capture of 98 percent. A method quantitation limit (MQL) of 0.5 ppbv was obtained for most of the target compounds. In examining daily control check runs, the variation of corrected GC retention times for each instrument and detector ranged from 0.023 to 0.044 minutes.

  2. Ambient Atmospheric Hydrocarbon Content as Determined by Gas Chromatographic Techniques from Rural Tidewater Virginia in Late Spring 1974

    NASA Technical Reports Server (NTRS)

    Copeland, G. E.; Davis, R.; Maroulis, P.; Bandy, A. R.; Denyszyn, R.; Kindle, E. C.

    1975-01-01

    In an attempt to ascertain the naturally generated hydrocarbon contribution to the air quality of the Hampton Roads region of Tidewater Virginia, a series of 27 air samples was obtained in two rural locations during late spring of 1974. These samples were analyzed for their hydrocarbon content (carbon number range C5 to C10) using gas chromatographic techniques. The thirty different hydrocarbon species were identified and monitored in the experiment. Preliminary analysis of the data indicates an average concentration of 397 parts per billion by weight (carbon) for the total non-methane hydrocarbon loading for C5 to C10 during the experiment. This value exceeds the National Primary Air Quality Standards as set by the Environmental Protection Agency.

  3. Cyclotriveratrylene as a new-type stationary phase for gas chromatographic separations of halogenated compounds and isomers.

    PubMed

    Lv, Qing; Zhang, Qing; Qi, Meiling; Bai, Hua; Ma, Qiang; Meng, Xianshuang; Fu, Ruonong

    2015-07-24

    Cyclotriveratrylene (CTV) is reported here for the first time as stationary phase for capillary gas chromatographic (GC) separations. CTV stationary phase showed weak polarity comparable to the conventional 5% phenyl polysiloxane stationary phase but exhibited different retention behaviours and higher resolution for some of the indicated analytes. Most importantly, CTV stationary phase exhibited preferential selectivity for halogenated compounds, positional and geometrical isomers. Effect of column temperature on retention and thermal stability of CTV column were also investigated. Moreover, CTV capillary column showed good repeatability in terms of run-to-run, day-to-day and column-to-column. The unique physicochemical features and efficient separation ability for analytes of close properties show the potential of CTV as a new-type stationary phase in GC as well as separation science. PMID:26051084

  4. Gas chromatographic determination of cholesterol and tocopherols in edible oils and fats with automatic removal of interfering triglycerides.

    PubMed

    Ballesteros, E; Gallego, M; Valcárcel, M

    1996-01-01

    An automated gas chromatographic method for the simultaneous determination of cholesterol, alpha-tocopherol and alpha-tocopheryl acetate in edible oils and fats without derivatization is reported. Interferences from lipid material are avoided by using a continuous system to transesterify triglycerides with potassium methylate in methanol. The precision of the method is 1.9, 2.2 and 3.1% for cholesterol, alpha-tocopherol and alpha-tocopheryl acetate, respectively. The proposed methods was validated by analysing a standard reference material of coconut oil (SRM 1563-2) with good results. The method features a high throughput, minimal sample handling and analyte specificity (lipid material does not interfere). PMID:8589831

  5. Fast low-pressure microwave assisted extraction and gas chromatographic determination of polychlorinated biphenyls in soil samples.

    PubMed

    Bruzzoniti, M C; Maina, R; Tumiatti, V; Sarzanini, C; Rivoira, L; De Carlo, R M

    2012-11-23

    A new technology equipment for low-pressure microwave assisted extraction (usually employed for organic chemistry reactions), recently launched in the market, is used for the first time in environmental analysis for the extraction of commercial technical Aroclor mixtures from soil. Certified reference materials of Aroclor 1260, Aroclor 1254 and Aroclor 1242 in transformer oils were used to contaminate the soil samples and to optimize the extraction method as well as the subsequent gas chromatographic electron capture detection (GC-ECD) analytical method. The study was performed optimizing the extraction, the purification and the gas chromatographic separation conditions to enhance the resolution of difficult pairs of congeners (C28/31 and C141/179). After optimization, the recovery yields were included within the range 79-84%. The detection limits, evaluated for two different commercial polychlorinated biphenyl (PCB) mixtures (Aroclor 1260 and Aroclor 1242) were 0.056 ± 0.001 mg/kg and 0.290 ± 0.006 mg/kg, respectively. The method, validated with certified soil samples, was used to analyze a soil sample after an event of failure of a pole-mounted transformer which caused the dumping of PCB contaminated oil in soil. Moreover, the method provides simple sample handling, fast extraction with reduced amount of sample and solvents than usually required, and simple purification step involving the use of solvent (cyclohexane) volumes as low as 5 mL. Reliability and reproducibility of extraction conditions are ensured by direct and continuous monitoring of temperature and pressure conditions. PMID:23084486

  6. Fast low-pressure microwave assisted extraction and gas chromatographic determination of polychlorinated biphenyls in soil samples.

    PubMed

    Bruzzoniti, M C; Maina, R; Tumiatti, V; Sarzanini, C; Rivoira, L; De Carlo, R M

    2012-11-23

    A new technology equipment for low-pressure microwave assisted extraction (usually employed for organic chemistry reactions), recently launched in the market, is used for the first time in environmental analysis for the extraction of commercial technical Aroclor mixtures from soil. Certified reference materials of Aroclor 1260, Aroclor 1254 and Aroclor 1242 in transformer oils were used to contaminate the soil samples and to optimize the extraction method as well as the subsequent gas chromatographic electron capture detection (GC-ECD) analytical method. The study was performed optimizing the extraction, the purification and the gas chromatographic separation conditions to enhance the resolution of difficult pairs of congeners (C28/31 and C141/179). After optimization, the recovery yields were included within the range 79-84%. The detection limits, evaluated for two different commercial polychlorinated biphenyl (PCB) mixtures (Aroclor 1260 and Aroclor 1242) were 0.056 ± 0.001 mg/kg and 0.290 ± 0.006 mg/kg, respectively. The method, validated with certified soil samples, was used to analyze a soil sample after an event of failure of a pole-mounted transformer which caused the dumping of PCB contaminated oil in soil. Moreover, the method provides simple sample handling, fast extraction with reduced amount of sample and solvents than usually required, and simple purification step involving the use of solvent (cyclohexane) volumes as low as 5 mL. Reliability and reproducibility of extraction conditions are ensured by direct and continuous monitoring of temperature and pressure conditions.

  7. A bond graph model for the sample extraction/injection system of a microsized gas chromatographic instrument

    NASA Astrophysics Data System (ADS)

    Lin, Jie; Wang, Wanjun; Murphy, Michael C.; Overton, Edward

    1996-09-01

    A bond graph model of the sample extraction/injection system of a prototype portable gas chromatographic instrument has been developed. In addition to performing the same functions as current portable gas chromatographs (GCs), the new generation of GC instruments is designed to perform extraction of analytes from liquid and solid samples. The prototype instrument achieves these improvements by taking of advantage of microfabrication technologies and microprocessor control in the design. A novel sample extraction/injection module is essential to the improved performance of the portable instrument, which will include microfabricated components such as inlets, interface chips, fluid channels, control valves, optimal heater/sensor combinations, and multiport connectors. In order to achieve the desired analytical performance, all of the major components are heated to 250 °C during different stages of a sample analysis. Predicting the performance of the system in this operating regime requires the modeling and analysis of system behavior in two interacting energy domains, fluid and thermal. This article represents the first effort to understand the dynamic behavior of the thermofluid aspect of micro-GC instruments and one of the first attempts to apply the widely-used bond graph technique to modeling and analysis of microsized thermofluid systems. Simulation results using the bond graph model closely match available experimental data, with differences typically less than 10%. This demonstrates that fluid dynamic theory for macroscale systems, and the bond graph method based on it, can be readily applied to microscale systems with these dimensions. The bond graph method can be a useful computer-aided design tool for the development of a new generation of truly integrated micro-GC instruments and sensors fabricated with micromachining technology.

  8. Integration of gas chromatographs into the Federal Highway Administration/Environmental Protection Agency near road MSAT study in Las Vegas, NV

    EPA Science Inventory

    This paper documents the technical evaluation of a semi-continuous gas chromatograph (GC) for the measurement of benzene and 1,33butadiene in the near road environment. This paper will also consider the some of the non-technical implications associated with the operation of a GC ...

  9. Evaluation of a gas chromatograph with a novel surface acoustic wave detector (SAW GC) for screening of volatile organic compounds in Hanford waste tank samples

    SciTech Connect

    Lockrem, L.L.

    1998-01-12

    A novel instrument, a gas chromatograph with a Surface Acoustic Wave Detector (SAW GC), was evaluated for the screening of organic compounds in Hanford tank headspace vapors. Calibration data were developed for the most common organic compounds, and the accuracy and precision were measured with a certified standard. The instrument was tested with headspace samples collected from seven Hanford waste tanks.

  10. Construction of a cryogen-free thermal desorption gas chromatographic system with off-the-shelf components for monitoring ambient volatile organic compounds.

    PubMed

    Ou-Yang, Chang-Feng; Liao, Wei-Cheng; Wang, Pei-Chieh; Fan, Gang-Jei; Hsiao, Chien-Cheng; Chuang, Ming-Tung; Chang, Chih-Chung; Lin, Neng-Huei; Wang, Jia-Lin

    2016-04-01

    An automated gas chromatographic system aimed at performing unattended measurements of ambient volatile organic compounds was configured and tested. By exploiting various off-the-shelf components, the thermal desorption unit was easily assembled and can be connected with any existing commercial gas chromatograph in the laboratory to minimize cost. The performance of the complete thermal desorption gas chromatographic system was assessed by analyzing a standard mixture containing 56 target nonmethane hydrocarbons from C2 -C12 at sub-ppb levels. Particular attention was given to the enrichment efficiency of the C2 compounds, such as ethane (b.p. = -88.6°C) and ethylene (b.p. = -104.2°C), due to their extremely high volatilities. Quality assurance was performed in terms of the linearity, precision and limits of detection of the target compounds. To further validate the system, field measurements of target compounds in ambient air were compared with those of a commercial total hydrocarbon analyzer and a carbon monoxide analyzer. Highly coherent results from the three instruments were observed during a two-month period of synchronized measurements. Moreover, the phenomenon of opposite diurnal variations between the biogenic isoprene and anthropogenic species was exploited to help support the field applicability of the thermal desorption gas chromatographic method. PMID:26924196

  11. Evaluation of the application of some gas chromatographic methods for the determination of properties of synthetic fuels

    NASA Technical Reports Server (NTRS)

    Antoine, A. C.

    1979-01-01

    The purpose of the investigation was to evaluate the applicability, to some synthetic fuels, of some gas chromatographic methods now under development for use with petroleum based fuels. Thirty-two jet and diesel fuel samples which were prepared from oil shale and coal syncrudes were examined. The boiling range distribution of each was determined by gas chromatography, and from that data distillation properties were calculated. The calculated results gave sufficient agreement with the measured values that the equations could be useable in their present form. Bulk fuel properties were calculated for the sixteen JP-5 and Diesel No. 2 type fuels. The results show that the equations would not give useable results. Capillary column gas chromatography was used to determine the n-alkane content of the eight JP-5 type samples and the results related to the observed freezing points. The results show that the concentrations of the long straight chain molecules in the fuels exert influence on the freezing point but are not the complete controlling factor.

  12. Characterization of gas-aerosol interaction kinetics using morphology dependent stimulated Raman scattering. 1992 Annual summary

    SciTech Connect

    Aker, P.M.

    1993-01-30

    This study is aimed at characterizing the influence of aerosol surface structure on the kinetics of gas-aerosol interactions. Changes in gas phase chemical reaction rates as a function of exposure to a specific aerosol are measured with aerosols having different surface properties due to the composition and/or temperature of the material making up the aerosol. The kinetic data generated can be used directly in atmospheric modeling calculations. The surface structure of the aerosol is using morphology-dependent enhancement of simulated Raman scattering (MDSRS). Detailed dynamics of gas-aerosol interactions can be obtained by correlating the change in the reaction rate with change in surface structure and by monitoring the change in aerosol surface structure during, the course of the reaction. This dynamics information can be used to generate kinetic data for systems which are similar in nature to those studied, but are not amenable to laboratory investigation. We show here that increased MDSRS sensitivity is achieved by using an excitation laser source that has a narrow linewidth and we have been able to detect sulfate anion concentrations much lower than previously reported. We have shown that the linewidth of the MDSRS mode excited in a droplet is limited by the laser linewidth. This is a positive result for it eases our ability to quantify the MDSRS gain equation. This result also suggests that MDSRS signal size should be independent of droplet size, and preliminary experiments confirm this hypothesis.

  13. Characterization of gas-aerosol interaction kinetics using morphology dependent stimulated Raman scattering

    SciTech Connect

    Aker, P.M.

    1993-01-30

    This study is aimed at characterizing the influence of aerosol surface structure on the kinetics of gas-aerosol interactions. Changes in gas phase chemical reaction rates as a function of exposure to a specific aerosol are measured with aerosols having different surface properties due to the composition and/or temperature of the material making up the aerosol. The kinetic data generated can be used directly in atmospheric modeling calculations. The surface structure of the aerosol is using morphology-dependent enhancement of simulated Raman scattering (MDSRS). Detailed dynamics of gas-aerosol interactions can be obtained by correlating the change in the reaction rate with change in surface structure and by monitoring the change in aerosol surface structure during, the course of the reaction. This dynamics information can be used to generate kinetic data for systems which are similar in nature to those studied, but are not amenable to laboratory investigation. We show here that increased MDSRS sensitivity is achieved by using an excitation laser source that has a narrow linewidth and we have been able to detect sulfate anion concentrations much lower than previously reported. We have shown that the linewidth of the MDSRS mode excited in a droplet is limited by the laser linewidth. This is a positive result for it eases our ability to quantify the MDSRS gain equation. This result also suggests that MDSRS signal size should be independent of droplet size, and preliminary experiments confirm this hypothesis.

  14. Long term aerosol and trace gas measurements in Central Amazonia

    NASA Astrophysics Data System (ADS)

    Artaxo, Paulo; Barbosa, Henrique M. J.; Ferreira de Brito, Joel; Carbone, Samara; Rizzo, Luciana V.; Andreae, Meinrat O.; Martin, Scot T.

    2016-04-01

    The central region of the Amazonian forest is a pristine region in terms of aerosol and trace gases concentrations. In the wet season, Amazonia is actually one of the cleanest continental region we can observe on Earth. A long term observational program started 20 years ago, and show important features of this pristine region. Several sites were used, between then ATTO (Amazon Tall Tower Observatory) and ZF2 ecological research site, both 70-150 Km North of Manaus, receiving air masses that traveled over 1500 km of pristine tropical forests. The sites are GAW regional monitoring stations. Aerosol chemical composition (OC/EC and trace elements) is being analysed using filters for fine (PM2.5) and coarse mode aerosol as well as Aerodyne ACSM (Aerosol Chemical Speciation Monitors). VOCs are measured using PTR-MS, while CO, O3 and CO2 are routinely measured. Aerosol absorption is being studied with AE33 aethalometers and MAAP (Multi Angle Absorption Photometers). Aerosol light scattering are being measured at several wavelengths using TSI and Ecotech nephelometers. Aerosol size distribution is determined using scanning mobility particle sizer at each site. Lidars measure the aerosol column up to 12 Km providing the vertical profile of aerosol extinction. The aerosol column is measures using AERONET sun photometers. In the wet season, organic aerosol comprises 75-85% of fine aerosol, and sulfate and nitrate concentrations are very low (1-3 percent). Aerosols are dominated by biogenic primary particles as well as SOA from biogenic precursors. Black carbon in the wet season accounts for 5-9% of fine mode aerosol. Ozone in the wet season peaks at 10-12 ppb at the middle of the day, while carbon monoxide averages at 50-80 ppb. Aerosol optical thickness (AOT) is a low 0.05 to 0.1 at 550 nm in the wet season. Sahara dust transport events sporadically enhance the concentration of soil dust aerosols and black carbon. In the dry season (August-December), long range transported

  15. Gas-aerosol cycling of ammonia and nitric acid in The Netherlands

    NASA Astrophysics Data System (ADS)

    Roelofs, Geert-Jan; Derksen, Jeroen

    2010-05-01

    Atmospheric ammonia and nitric acid are present over NW Europe in large abundance. Observations made during the IMPACT measurement campaign (May 2008, Cabauw, The Netherlands) show a pronounced diurnal cycle of aerosol ammonium and nitrate on relatively dry days. Simultaneously, AERONET data show a distinct diurnal cycle in aerosol optical thickness (AOT). We used a global aerosol-climate model (ECHAM5-HAM) and a detailed aerosol-cloud column model to help analyse the observations from this period. The study shows that the diurnal cycle in AOT is partly associated with particle number concentration, with distinct peaks in the morning and evening. More important is relative humidity (RH). RH maximizes in the night and early morning, decreases during the morning and increases again in the evening. The particle wet radius, and therefore AOT, changes accordingly. In addition, the RH variability also influences chemistry associated with ammonia and nitric acid (formation of ammonium nitrate, dissolution in aerosol water), resulting in the observed diurnal cycle of aerosol ammonium and nitrate. The additional aerosol matter increases the hygroscopicity of the particles, and this leads to further swelling by water vapor condensation and a further increase of AOT. During the day, as RH decreases and the particles shrink, aerosol ammonium and nitrate are again partly expelled to the gas phase. This behaviour contributes significantly to the observed diurnal cycle in AOT, and it illustrates the complexity of using AOT as a proxy for aerosol concentrations in aerosol climate studies in the case of heavily polluted areas.

  16. Gas-Chromatographic analysis of Mars soil samples with the SAM instrument onboard Curiosity - the 359 first sols

    NASA Astrophysics Data System (ADS)

    Szopa, Cyril; Navarro-Gonzalez, Rafael; Mahaffy, Paul; Buch, Arnaud; Goutail, Jean Pierre; Cabane, Michel; Glavin, Daniel; Correia, Jean-Jacques; Coll, Patrice; Freissinet, Caroline; Meftah, Mustapha; Coscia, David; Teinturier, Samuel; Brunner, Anna; Bonnet, Jean-Yves; Millan, Maeva; Pascalin

    Amongst the SAM suite of instruments, SAM-GC (Gas Chromatograph) is devoted to identify and quantify volatiles evolved from the thermal/chemical treatment of any soil sample collected by the Curiosity rover. The first soil samples analyzed with SAM were composed of windblown dust and sand collected at the Rocknest site, while the second site analyzed was a basin called “Yellowknife Bay” where two holes were drilled (John Klein & Cumberland) and analysis showed these sites to be a fluvio-lacustrine sediment.. For their analysis, these samples were subjected to a pyrolysis at temperatures reaching about 850°C. For SAM-GC and GCMS analyses, different fractions of pyrolysates were collected at different temperature in the ambient-900°C range in order to discriminate potential different volatile fractions present in the solid sample. With the aim to search for potential organic molecules outgassed from the samples, a SAM-GC analytical channel composed of a thermal-desorption injector and a MXT-CLP chromatographic column was used as it was designed for the separation of a wide range of volatile organic molecules. This channel is also equipped with a thermal conductivity detector (TCD) capable to detect the most abundant species (with abundances down to approximately 10-10mol). His channel is thus complementary to the mass spectrometer detection for quantification of such species, as this last instrument does not have linear response in this domain of high abundance, whereas it is significantly more sensitive than the TCD. The results obtained with this instrument first show that the performances of SAM-GC is representative of those obtained during calibrations of the instrument in laboratory, and also that results are repeatable. Hence, the instrument performs nominally, making it the first GCMS running successfully on Mars since the Viking missions (middle of the 70’s). Moreover, the complementarity of GC towards MS is also shown, both by allowing the

  17. Gas Chromatographic Determination of Methyl Salicylate in Rubbing Alcohol: An Experiment Employing Standard Addition.

    ERIC Educational Resources Information Center

    Van Atta, Robert E.; Van Atta, R. Lewis

    1980-01-01

    Provides a gas chromatography experiment that exercises the quantitative technique of standard addition to the analysis for a minor component, methyl salicylate, in a commercial product, "wintergreen rubbing alcohol." (CS)

  18. Global Impacts of Gas-Phase Chemistry-Aerosol Interactions on Direct Radiative Forcing by Anthropogenic Aerosols and Ozone

    NASA Technical Reports Server (NTRS)

    Liao, Hong; Seinfeld, John H.

    2005-01-01

    We present here a first global modeling study on the influence of gas-phase chemistry/aerosol interactions on estimates of anthropogenic forcing by tropospheric O3 and aerosols. Concentrations of gas-phase species and sulfate, nitrate, ammonium, black carbon, primary organic carbon, secondary organic carbon, sea salt, and mineral dust aerosols in the preindustrial, present-day, and year 2100 (IPCC SRES A2) atmospheres are simulated online in the Goddard Institute for Space Studies general circulation model II' (GISS GCM II'). With fully coupled chemistry and aerosols, the preindustrial, presentday, and year 2100 global burdens of tropospheric ozone are predicted to be 190, 319, and 519 Tg, respectively. The burdens of sulfate, nitrate, black carbon, and organic carbon are predicted respectively to be 0.32. 0.18, 0.01, 0.33 Tg in preindustrial time, 1.40, 0.48, 0.23, 1.60 Tg in presentday, and 1.37, 1.97, 0.54, 3.31 Tg in year 2100. Anthropogenic O3 is predicted to have a globally and annually averaged present-day forcing of +0.22 W m(sup -2) and year 2100 forcing of +0.57 W m(sup -2) at the top of the atmosphere (TOA). Net anthropogenic TOA forcing by internally mixed sulfate, nitrate, organic carbon, and black carbon aerosols is estimated to be virtually zero in the present-day and +0.34 W m(sup -2) in year 2100, whereas it is predicted to be -0.39 W m(sup -2) in present-day and -0.61 W m(sup -2) in year 2100 if the aerosols are externally mixed. Heterogeneous reactions are shown to be important in affecting anthropogenic forcing. When reactions of N2O5, NO3, NO2, and HO2 on aerosols are accounted for, TOA anthropogenic O3 forcing is less by 20-45% in present-day and by 20-32% in year 2100 at mid to high latitudes in the Northern Hemisphere, as compared with values predicted in the absence of heterogeneous gas aerosol reactions. Mineral dust uptake of HNO3 and O3 is shown to have practically no influence on anthropogenic O3 forcing. Heterogeneous reactions of N2Os

  19. Single-walled carbon nanotubes as stationary phase in gas chromatographic separation and determination of argon, carbon dioxide and hydrogen.

    PubMed

    Safavi, Afsaneh; Maleki, Norooz; Doroodmand, Mohammad Mahdi

    2010-08-24

    A chromatographic technique is introduced based on single-walled carbon nanotubes (SWCNTs) as stationary phase for separation of Ar, CO(2) and H(2) at parts per million (ppm) levels. The efficiency of SWCNTs was compared with solid materials such as molecular sieve, charcoal, multi-walled carbon nanotubes and carbon nanofibers. The morphology of SWCNTs was optimized for maximum adsorption of H(2), CO(2) and Ar and minimum adsorption of gases such as N(2), O(2), CO and H(2)O vapour. To control temperature of the gas chromatography column, peltier cooler was used. Mixtures of Ar, CO(2) and H(2) were separated according to column temperature program. Relative standard deviation for nine replicate analyses of 0.2 mL H(2) containing 10 microL of each Ar or CO(2) was 2.5% for Ar, 2.8% for CO(2) and 3.6% for H(2). The interfering effects of CO, and O(2) were investigated. Working ranges were evaluated as 40-600 ppm for Ar, 30-850 ppm for CO(2) and 10-1200 ppm for H(2). Significant sensitivity, small relative standard deviation (RSD) and acceptable limit of detection (LOD) were obtained for each analyte, showing capability of SWCNTs for gas separation and determination processes. Finally, the method was used to evaluate the contents of CO(2) in air sample.

  20. Capillary gas chromatographic determination of putrescine and cadaverine in serum of cancer patients using trifluoroacetylacetone as derivatizing reagent.

    PubMed

    Khuhawar, M Y; Memon, A A; Jaipal, P D; Bhanger, M I

    1999-02-19

    Trifluoroacetylacetone (FAA) derivatives of 1,4-diaminobutane (putrescine) (Pu) and 1,5-diaminopentane (cadaverine) (CA) were prepared and characterized by elemental microanalysis, IR, and mass spectrometry. Diamine derivatives were eluted from capillary gas chromatographic (CGC) column BP1 (12 m x 0.22 mm I.D.) or BP5 (50 m x 0.22 mm) with layer thickness 0.25 microm, using nitrogen as a carrier gas and flame ionization detection (FID). A solvent extraction procedure was developed for the extraction of Pu and CA from aqueous solution with a linear calibration range 0-20 microg/0.2 ml of extract with a detection limit of 0.5-0.6 ng/injection. The method was applied for the determination of Pu and CA in the serum of five cancer patients before and after radiotherapy. The serum of two healthy persons was also analyzed for Pu and CA contents. Pu and CA concentrations were found within the range 1.16-3.96 microg/ml and 0.88-1.46 microg/ml in cancer patients as compared to 0.11-0.16 microg/ml and 0.06-0.075 microg/ml respectively in healthy persons with a coefficient of variation (CV) within 0.62-5.47%. Pu and CA concentrations decreased on radiotherapy in cancer patients, but were much higher than in healthy persons. PMID:10080628

  1. A gas chromatographic method for the indirect determination of hydroxylamine in pharmaceutical preparations: conversion into nitrous oxide.

    PubMed

    Guzowski, J P; Golanoski, C; Montgomery, E R

    2003-12-01

    A simple, sensitive, and selective headspace gas-chromatographic method has been developed for measuring hydroxylamine (HA) in a variety of sample matrices including pharmaceutical formulations. This procedure relies on converting HA into nitrous oxide (N2O), which is a single-step reaction that is carried out directly in a heated headspace vial. The gaseous products are then analyzed by headspace capillary gas chromatography. Several detection strategies were evaluated and electron capture provided the best sensitivity (4 parts-per-billion (ppb)) while the mass selective and thermal conductivity values were higher (14 ppb and 1.4 parts-per-million (ppm), respectively). The method's linear dynamic range spans two to four decades with a run-to-run precision that was better than 5% R.S.D. (n=7). The reagent concentrations (oxidant, buffer) strongly impact the N2O signal and the greatest response was obtained for solutions that contained equimolar amounts of reactants. HA was efficiently (98%) recovered from a sample matrix that contained only the active pharmaceutical ingredient (API) but the recovery was lower (83%) when excipients were present.

  2. Development of High Precision Metal Micro-Electro-Mechanical-Systems Column for Portable Surface Acoustic Wave Gas Chromatograph

    NASA Astrophysics Data System (ADS)

    Iwaya, Takamitsu; Akao, Shingo; Sakamoto, Toshihiro; Tsuji, Toshihiro; Nakaso, Noritaka; Yamanaka, Kazushi

    2012-07-01

    In the field of environmental measurement and security, a portable gas chromatograph (GC) is required for the on-site analysis of multiple hazardous gases. Although the gas separation column has been downsized using micro-electro-mechanical-systems (MEMS) technology, an MEMS column made of silicon and glass still does not have sufficient robustness and a sufficiently low fabrication cost for a portable GC. In this study, we fabricated a robust and inexpensive high-precision metal MEMS column by combining diffusion-bonded etched stainless-steel plates with alignment evaluation using acoustic microscopy. The separation performance was evaluated using a desktop GC with a flame ionization detector and we achieved the high separation performance comparable to the best silicon MEMS column fabricated using a dynamic coating method. As an application, we fabricated a palm-size surface acoustic wave (SAW) GC combining this column with a ball SAW sensor and succeeded in separating and detecting a mixture of volatile organic compounds.

  3. Secondary Organic Aerosol formation from the gas-phase reaction of catechol with ozone

    NASA Astrophysics Data System (ADS)

    Coeur-Tourneur, C.; Tomas, A.; Guilloteau, A.; Henry, F.; Ledoux, F.; Visez, N.; Riffault, V.; Wenger, J. C.; Bedjanian, Y.; Foulon, V.

    2009-04-01

    The formation of secondary organic aerosol from the gas-phase reaction of catechol (1,2-dihydroxybenzene) with ozone has been studied in two smog chambers (at the LPCA in France and at the CRAC in Ireland). Aerosol production was monitored using a scanning mobility particle sizer. The overall organic aerosol yield (Y) was determined as the ratio of the suspended aerosol mass corrected for wall losses (Mo) to the total reacted catechol concentrations, assuming a particle density of 1.4 g cm-3. Analysis of the data clearly shows that Y is a strong function of Mo and that secondary organic aerosol formation can be expressed by a one-product gas/particle partitioning absorption model. The aerosol formation is affected by the initial catechol concentration, which leads to aerosol yields ranging from 17% to 86%. The aerosol yields determined in the LPCA and CRAC smog chambers were comparable and were also in accordance with those determined in a previous study performed in EUPHORE (EUropean PHOto REactor, Spain).

  4. Ammonia Analysis by Gas Chromatograph/Infrared Detector (GC/IRD)

    NASA Technical Reports Server (NTRS)

    Scott, Joseph P.; Whitfield, Steve W.

    2003-01-01

    Methods are being developed at Marshall Space Flight Center's Toxicity Lab on a CG/IRD System that will be used to detect ammonia in low part per million (ppm) levels. These methods will allow analysis of gas samples by syringe injections. The GC is equipped with a unique cryogenic-cooled inlet system that will enable our lab to make large injections of a gas sample. Although the initial focus of the work will be analysis of ammonia, this instrument could identify other compounds on a molecular level. If proper methods can be developed, the IRD could work as a powerful addition to our offgassing capabilities.

  5. Gas chromatographic determination of benzene, toluene, ethylbenzene and xylenes using flame ionization detector in water samples with direct aqueous injection up to 250 microl.

    PubMed

    Kubinec, R; Adamuscin, J; Jurdáková, H; Foltin, M; Ostrovský, I; Kraus, A; Soják, L

    2005-08-19

    A simple method of solventless extraction of volatile organic compounds (benzene, toluene, ethylbenzene and xylenes) from aqueous samples was developed. This method allows direct injection of large volume of water sample into a gas chromatograph using the sorption capacity of the sorbent Chromosorb P NAW applied directly in the injection port of gas chromatograph. The system prevent water penetration into a column, keep it adsorbed on its surface until the analytes are stripped into a column, and the residual water is purging using split flow. The limit of detection ranging from 0.6 for benzene to 1.1 microg l(-1) for o-xylene and limit of quantification ranging 2.0-3.6 microg l(-1) are lower that those reached by gas chromatography with flame ionization detection and direct aqueous injection before.

  6. Gas Chromatographic Verification of a Mathematical Model: Product Distribution Following Methanolysis Reactions.

    ERIC Educational Resources Information Center

    Lam, R. B.; And Others

    1983-01-01

    Investigated application of binomial statistics to equilibrium distribution of ester systems by employing gas chromatography to verify the mathematical model used. Discusses model development and experimental techniques, indicating the model enables a straightforward extension to symmetrical polyfunctional esters and presents a mathematical basis…

  7. Development of a harmonised method for the profiling of amphetamines: III. Development of the gas chromatographic method.

    PubMed

    Andersson, Kjell; Jalava, Kaisa; Lock, Eric; Finnon, Yvonne; Huizer, Henk; Kaa, Elisabet; Lopes, Alvaro; Poortman-van der Meer, Anneke; Cole, Michael D; Dahlén, Johan; Sippola, Erkki

    2007-06-14

    This study focused on gas chromatographic analysis of target compounds found in illicit amphetamine synthesised by the Leuckart reaction, reductive amination of benzyl methyl ketone, and the nitrostyrene route. The analytical method was investigated and optimised with respect to introduction of amphetamine samples into the gas chromatograph and separation and detection of the target substances. Sample introduction using split and splitless injection was tested at different injector temperatures, and their ability to transfer the target compounds to the GC column was evaluated using cold on column injection as a reference. Taking the results from both techniques into consideration a temperature of 250 degrees C was considered to be the best compromise. The most efficient separation was achieved with a DB-35MS capillary column (35% diphenyl 65% dimethyl silicone; 30 m x 0.25 mm, d(f) 0.25 microm) and an oven temperature program that started at 90 degrees C (1 min) and was increased by 8 degrees C/min to 300 degrees C (10 min). Reproducibility, repeatability, linearity, and limits of determination for the flame ionisation detector (FID), nitrogen phosphorous detector (NPD), and mass spectrometry (MS) in scan mode and selected ion monitoring (SIM) mode were evaluated. In addition, selectivity was studied applying FID and MS in both scan and SIM mode. It was found that reproducibility, repeatability, and limits of determination were similar for FID, NPD, and MS in scan mode. Moreover, the linearity was better when applying FID or NPD whereas the selectivity was better when utilising the MS. Finally, the introduction of target compounds to the GC column when applying injection volumes of 0.2 microl, 1 microl, 2 microl, and 4 microl with splitless injection respectively 1 microl with split injection (split ratio, 1:40) were compared. It was demonstrated that splitless injections of 1 microl, 2 microl, and 4 microl could be employed in the developed method, while split

  8. The Stratospheric Aerosol and Gas Experiment III - International Space Station: Extending Long-Term Ozone and Aerosol Observations (Invited)

    NASA Astrophysics Data System (ADS)

    Eckman, R.; Zawodny, J. M.; Cisewski, M.; Gasbarre, J.; Flittner, D. E.; Hill, C.; Roell, M.; Moore, J. R.; Hernandez, G.; McCormick, M. P.

    2013-12-01

    The Stratospheric Aerosol and Gas Experiment III - International Space Station (SAGE III on ISS) will extend the global measurements of vertical profiles of ozone, aerosols, water vapor, nitrogen dioxide, and other trace gases begun with SAGE I in 1979, enabling the detection of long-term trends. SAGE III on ISS is the fourth in a series of instruments developed for monitoring these constituents in the stratosphere and troposphere. The SAGE III instrument is a moderate resolution spectrometer covering wavelengths from 290 nm to 1550 nm, using the heritage occultation technique, utilizing both the sun and the moon. Launch to ISS is planned for early 2015 aboard a Falcon 9 spacecraft. SAGE III will investigate the spatial and temporal variability of the measured species in order to determine their role in climatological processes, biogeochemical cycles, the hydrologic cycle, and atmospheric chemistry. It will characterize tropospheric, as well as stratospheric aerosols and upper tropospheric and stratospheric clouds, and investigate their effects on the Earth's environment including radiative, microphysical, and chemical interactions. The multi-decadal SAGE ozone and aerosol data sets have undergone intense scrutiny and are the international standard for accuracy and stability. SAGE data have been used to monitor the effectiveness of the Montreal Protocol. Amongst its key objectives will be to assess the state of the recovery in the distribution of ozone, to reestablish the aerosol measurements needed by both climate and ozone models, and to gain further insight into key processes contributing to ozone and aerosol variability. The ISS is ideal for Earth observing experiments; its mid-inclination orbit allows for a large range in latitude sampling and nearly continuous communications with payloads. In this presentation, we describe the SAGE III on ISS mission, its implementation, current status, and concentrate on its key science objectives.

  9. Versatile and fast gas chromatographic determination of frequently used brominated flame retardants in styrenic polymers.

    PubMed

    Pöhlein, Manfred; Bertran, Raquel Urpi; Wolf, Marion; van Eldik, Rudi

    2008-09-01

    Two versatile and fast methods to identify and quantify brominated flame retardants (BrFRs) in styrenic polymers were developed. Gas chromatography/mass spectrometry (GC/MS) as well as gas chromatography with electron-capture detection (GC/ECD), both following ultrasonic-supported dissolution and precipitation (USDP), were applied. The substance range includes poly-brominated biphenyls (PBBs) and diphenyl ethers (PBDEs), as well as other commonly used flame retardants (FRs), including two phosphate-based flame retardants. The methods were verified using congener standards and flame-retardant polymer samples. Good recoveries were found. Overall run time for the analysis, including sample preparation, is less than 60 min. PMID:18687441

  10. Determination of partition coefficients of refrigerants by gas liquid chromatographic headspace analysis.

    PubMed

    Abraham, Michael H; Gil-Lostes, Javier; Corr, Stuart; Acree, William E

    2012-11-23

    Gas-water partition coefficients, K(w), and gas-solvent partition coefficients, K(s), have been determined for chlorodifluoromethane and for 1,1,1,3,3,3-hexafluoropropane by headspace analysis, using a very simple experimental procedure. These partition coefficients then yield water-solvent partition coefficients, P(s). Where comparisons can be made there is excellent agreement with literature values for K(w) and P(s). The obtained values of K(s) and P(s) can be used to obtain physicochemical properties, or descriptors, for the refrigerants. Combination of these descriptors with previous equations we have developed enables partition coefficients to be obtained for a host of systems.

  11. Flat plate film cooling measurement using PSP and gas chromatograph techniques

    SciTech Connect

    Zhang, L.J.; Fox, M.

    1999-07-01

    The use of pressure sensitive paint (PSP) to measure film cooling effectiveness is demonstrated in a high speed wind tunnel using a flat plate. To validate this technology, gas chromatography was used to measure film cooling effectiveness from the same plate. Four (4) blowing ratios 0.5, 0.75, 1.0 and 1.5 were tested using the two methods. The flow stream turbulence effect was not studied and the free stream turbulence intensity was fixed at 4.0%. The PSP was calibrated at various temperatures as well as at various pressures before testing. The test results on the flat plate indicate that the PSP method of measuring film cooling effectiveness is far superior than the traditional gas chromatography method. The better spatial resolution and two dimensionality of the pressure sensitive paint method offers a great potential for its application in film cooling measurements.

  12. Determination of partition coefficients of refrigerants by gas liquid chromatographic headspace analysis.

    PubMed

    Abraham, Michael H; Gil-Lostes, Javier; Corr, Stuart; Acree, William E

    2012-11-23

    Gas-water partition coefficients, K(w), and gas-solvent partition coefficients, K(s), have been determined for chlorodifluoromethane and for 1,1,1,3,3,3-hexafluoropropane by headspace analysis, using a very simple experimental procedure. These partition coefficients then yield water-solvent partition coefficients, P(s). Where comparisons can be made there is excellent agreement with literature values for K(w) and P(s). The obtained values of K(s) and P(s) can be used to obtain physicochemical properties, or descriptors, for the refrigerants. Combination of these descriptors with previous equations we have developed enables partition coefficients to be obtained for a host of systems. PMID:23089519

  13. A pyrolysis/gas chromatographic method for the determination of hydrogen in solid samples

    NASA Technical Reports Server (NTRS)

    Carr, R. H.; Bustin, R.; Gibson, E. K.

    1987-01-01

    A method is described for the determination of hydrogen in solid samples. The sample is heated under vacuum after which the evolved gases are separated by gas chromatography with a helium ionization detector. The system is calibrated by injecting known amounts of hydrogen, as determined manometrically. The method, which is rapid and reliable, was checked for a variety of lunar soils; the limit of detection is about 10 ng of hydrogen.

  14. Gas chromatographic/mass spectrometric determination of lysergic acid diethylamide (LSD) in serum samples.

    PubMed

    Musshoff, F; Daldrup, T

    1997-08-01

    A sensitive method for the detection and quantification of lysergic acid diethylamide (LSD) in serum samples is described. After liquid-liquid extraction the trimethylsilyl derivative of LSD is detected by gas chromatography-mass spectrometry. Experiments with spiked samples resulted in a recovery of 76%, the coefficient of variation was 9.3%. Excellent linearity was obtained over the range 0.1-10 ng ml-1. Additionally experiments demonstrating the light sensitivity of LSD are presented together with casuistics.

  15. On-line gas chromatographic studies of rutherfordium (Element 104), hahnium (Element 105), and homologs

    SciTech Connect

    Kadkhodayan, B.

    1993-05-01

    Gas-phase isothermal chromatogaphy is a method by which volatile compounds of different chemical elements can be separated according to their volatilities. The technique, coupled with theoretical modeling of the processes occurring in the chromatogaphy column, provides accurate determination of thermodynamic properties (e.g., adsorption enthalpies) for compounds of elements, such as the transactinides, which can only be produced on an atom-at-a-time basis. In addition, the chemical selectivity of the isothermal chromatogaphy technique provides the decontamination from interfering activities necessary for the determination of the nuclear decay properties of isotopes of the transactinide elements. Volatility measurements were performed on chloride species of Rf and its group 4 homologs, Zr and Hf, as well as Ha and its group 5 homologs, Nb and Ta. Adsorption enthalpies were calculated for all species using a Monte Carlo code simulation based on a microscopic model for gas thermochromatography in open columns with laminar flow of the carrier gas. Preliminary results are presented for Zr- and Nb-bromides.

  16. Quantifying Aerosol Types and Their Impact on Trace Gas Retrievals From Satellite Measurements

    NASA Astrophysics Data System (ADS)

    Natraj, V.; Boesch, H.; Yung, Y. L.

    2005-12-01

    One of the major sources of uncertainty in the retrieval of trace gas abundances from space-borne measurements is the type, amount and vertical distribution of aerosols in the atmosphere. Optical properties were derived for the broad classification of aerosol types investigated by Kahn et al. (2001), taking polarization into account. Examination of the scattering matrix elements resulted in a smaller set of independent aerosol types whose radiative effects were different. Weighting functions were then calculated for each of these types, assuming exponentially tailing aerosol concentration in the troposphere and a Junge distribution for the stratosphere. The different shapes of the weighting functions indicate different amount and distribution of the information content. Implications for trace gas retrievals from satellite-based measurements made by polarization-sensitive instruments (such as those on OMI, GOME, SCIAMACHY and OCO) will be discussed.

  17. Secondary Organic Aerosol formation from the gas-phase ozonolysis of 3-methylcatechol and 4-methylcatechol

    NASA Astrophysics Data System (ADS)

    Coeur-Tourneur, Cécile; Foulon, Valentine; Laréal, Michel; Cassez, Andy; Zhao, Weixiong

    2010-05-01

    Secondary Organic Aerosol (SOA) formation during the ozonolysis of 3-methylcatechol (3-methyl-1,2-dihydroxybenzene) and 4-methylcatechol (3-methyl-1,2-dihydroxybenzene) was investigated using a simulation chamber (8 m3) at atmospheric pressure, room temperature (294 ± 2 K) and low relative humidity (5-10%). The initial mixing ratios were as follows (in ppb): 3-methylcatechol (194-1059), 4-methylcatechol (204-1188) and ozone (93-531). The ozone and methylcatechol concentrations were followed by UV photometry and GC-FID (Gas Chromatography - Flame ionization detector), respectively and the aerosol production was monitored using a SMPS (Scanning Mobility Particle Sizer). The SOA yields (Y) were determined as the ratio of the suspended aerosol mass corrected for wall losses (Mo) to the total reacted methylcatechol concentrations assuming a particle density of 1.4 g cm-3. The aerosol formation yield increases as the initial methylcatechol concentration increases, and leads to aerosol yields ranging from 32% to 67% and from 30% to 64% for 3-methylcatechol and 4-methylcatechol, respectively. Y is a strong function of Mo and the organic aerosol formation can be expressed by a one-product gas/particle partitioning absorption model. These data are comparable to those published in a recent study on secondary organic aerosol formation from catechol ozonolysis. To our knowledge, this work represents the first investigation of SOA formation from the ozone reaction with methylcatechols.

  18. [Bronchodilator aerosol propellant interferes with an photoacoustic spectrophotometer respiratory gas analyzer].

    PubMed

    Makino, A; Morimoto, Y; Matsumoto, S; Oka, H; Shimizu, K; Miyauchi, Y

    1998-05-01

    A patient with bronchial asthma was scheduled for an operation under nitrous oxide-isoflurane anesthesia. We monitored isoflurane concentrations continuously using an anesthetic gas analyzer (BK 1304). Upon puffing procaterol hydrochloride aerosol for 4 times, the analyzer showed a rapid increase in end-tidal isoflurane concentration. The BK 1304 uses infrared photoacoustic spectrophotometry and it is susceptible to interferences caused by Freon propellants in bronchodilator aerosols. We should take care in monitoring inhalational anesthetics when using aerosols containing Freon propellants. PMID:9621676

  19. Integration and Ruggedization of a Commercially Available Gas Chromatograph and Mass Spectrometer (GCMS) for the Resource Prospector Mission (RPM)

    NASA Technical Reports Server (NTRS)

    Loftin, Kathleen; Griffin, Timothy; Captain, Janine

    2013-01-01

    The Resource Prospector is a mission to prospect for lunar volatiles (primarily water) at one of the two lunar poles, as well as demonstrate In-Situ Resource Utilization (ISRU) on the Moon. The Resource Prospector consists of a lander, a rover, and a rover-borne scientific payload. The Regolith and Environment Science and Oxygen & Lunar Volatile Extraction (RESOLVE) payload, will be able to (1) locate near subsurface volatiles, (2) excavate and analyze samples of the volatile-bearing regolith, and (3) demonstrate the form, extractability and usefulness of the materials. The gas chromatograph mass spectrometer (GCMS) is the primary instrument in the RESOLVE instrumentation suite responsible for identification and quantification of the volatiles evolved from the lunar regolith. Specifically, this instrument must have: a low mass, a low power consumption, be able to perform fast analyses of samples ranging from less than one to greater than ninety nine percent water by mass, be autonomously controlled by the payload's software and avionics platform, and be able to operate in the harsh lunar environment. The RPM's short mission duration is the primary driver of the requirement for a very fast analysis time currently base lined at less than 2 minutes per sample. This presentation will discuss the requirements levied upon the GCMS design, lessons learned from a preliminary field demonstration deployment, the current design, and the path forward.

  20. Fast gas chromatographic residue analysis in animal feed using split injection and atmospheric pressure chemical ionisation tandem mass spectrometry.

    PubMed

    Tienstra, M; Portolés, T; Hernández, F; Mol, J G J

    2015-11-27

    Significant speed improvement for instrumental runtime would make GC–MS much more attractive for determination of pesticides and contaminants and as complementary technique to LC–MS. This was the trigger to develop a fast method (time between injections less than 10 min) for the determination of pesticides and PCBs that are not (or less) amenable to LC–MS. A key factor in achieving shorter analysis time was the use of split injection (1:10) which allowed the use of a much higher initial GC oven temperature. A shorter column (15 m), higher temperature ramp, and higher carrier gas flow rate (6 mL/min) further contributed to analysis-time reduction. Chromatographic resolution was slightly compromised but still well fit-for-purpose. Due to the high sensitivity of the technique used (GC–APCI-triple quadrupole MS/MS), quantification and identification were still possible down to the 10 μg/kg level, which was demonstrated by successful validation of the method for complex feed matrices according to EU guidelines. Other advantages of the method included a better compatibility of acetonitrile extracts (e.g. QuEChERS) with GC, and a reduced transfer of co-extractants into the GC column and mass spectrometer. PMID:26601712

  1. Gas-chromatographic measurements of atmospheric CF2Cl2, CFCl3 and N2O in Antarctica

    NASA Technical Reports Server (NTRS)

    Hirota, H.; Makino, Y.; Chubachi, S.; Muramatsu, H.; Shiobara, M.

    1985-01-01

    Stratospheric ozone is produced photochemically and destroyed by reactions with such minor constituents as O, NOx, HOx, and ClOx. Chlorofluoromethanes (CF2Cl2 and CFCl3) and dinitrogen oxide (NwO) are considered as major sources of the stratospheric ClOx and NOx, respectively. It is well known that CF2Cl2 and CFCl3 are released only by man's activities, and are being accumulated in the troposphere. In order to assess the influence of these compounds on the natural ozone balance these gases have been measured over Japan since 1978. Measurements of Antarctic air samples are also indispensable to understanding the global distributions of these gases, because most CF2Cl2 and CFCl3 have been released in the Northern Hemisphere. Antarctic air samples were obtained by the 23rd, 24th and 25th Japanese Antarctic Research Expeditions, and analyzed by a gas-chromatographic method using an electron capture detector. Three experimental results were obtained: (1) latitudinal distribution of these gases from Tokyo to Syowa Station (69.0 deg S, 39.6 deg E), (2) time trends at Syowa Station, and (3) vertical distributions over Syowa Station. Results are reported.

  2. New high-performance cryofocalizer injector for in-tube solid-phase microextraction and headspace capillary gas chromatographic applications.

    PubMed

    Nardi, Luigi

    2003-01-24

    The construction of a high-efficiency but cheap injector for volatile and very volatile compounds is shown. The device focuses the compounds in a fused-silica (FS) transfer capillary with the aid of liquid nitrogen. A 6.2 mm O.D. glass tube liner (ca. 25 cm x 1.5 mm I.D.) is inserted in the heated (-200 degrees C) injector of the gas chromatograph in place of the standard glass liner, and extends further externally through a liquid nitrogen container made with styrofoam-like material. Inside this glass tube, the FS transfer line passing through the oven door is connected like a pre-column to the analytical high-resolution GC column. It can move fast between the heated and the cooled zone (<-->, deltaL = 13 cm), and when this movement starts, crvofocused analytes are injected "at once" resulting in symmetrical and sharp injection bands with "zero" carryover. The performance of this device is demonstrated by its application to in-tube solid-phase microextraction and to spice volatiles analysis.

  3. Gas chromatographic separation of stereoisomers of non-protein amino acids on modified γ-cyclodextrin stationary phase.

    PubMed

    Fox, Stefan; Strasdeit, Henry; Haasmann, Stephan; Brückner, Hans

    2015-09-11

    Stereoisomers (enantiomers and diastereoisomers) of synthetic, non-protein amino acids comprising α-, β-, and γ-amino acids, including α,α-dialkyl amino acids, were converted into the respective N-trifluoroacetyl-O-methyl esters and analyzed and resolved by gas chromatography (GC) on a commercial fused silica capillary column coated with the chiral stationary phase octakis(3-O-butyryl-2,6-di-O-pentyl)-γ-cyclodextrin. This column is marketed under the trade name Lipodex(®) E. Chromatograms, retention times, and a chart displaying the retention times of approximately 40 stereoisomers of amino acids are presented. With few exceptions, baseline or almost baseline resolution was achieved for enantiomers and diastereoisomers. The chromatographic method presented is considered to be highly suitable for the elucidation of the stereochemistry of non-protein amino acids, for example in natural products, and for evaluating the enantiopurity of genetically non-coded amino acids used for the synthesis and design of conformationally tailored peptides. The method is applicable to extraterrestrial materials or can be used in experimental work related to abiotic syntheses or enantioselective destruction and amplification of amino acids. PMID:26278360

  4. Development of automated online gel permeation chromatography-gas chromatograph mass spectrometry for measuring multiresidual pesticides in agricultural products.

    PubMed

    Liu, Li-Bin; Hashi, Yuki; Qin, Ya-Ping; Zhou, Hai-Xia; Lin, Jin-Ming

    2007-01-01

    An automated online gel permeation chromatography-gas chromatograph mass spectrometer (GPC-GC/MS) was developed for the rapid determination of residual pesticides in agricultural products. Pesticides were extracted from homogenized food samples with acetonitrile and decontaminated via the matrix solid-phase dispersion (MSPD) technique, using a primary secondary amine as sorbent prior to GPC-GC/MS analysis. A slightly modified preparation method and automated GPC step proved useful in minimizing matrix interference. To evaluate the performance of the system, 97 target pesticides were spiked at a concentration of 0.1mg/kg into a range of food types, including potato, cabbage, carrot, apple, orange, cucumber, and rice. A low flow rate of 0.1 mL/min in GPC resulted in a 40-fold reduction in solvent consumption compared with conventional GPC column applications. The combination of MSPD technique and GPC-GC/MS for the analysis of the 97 pesticides can be accomplished within 90 min. Most pesticides were recovered in the range of 70-120%, with relative standard deviation generally less than 10%. The results demonstrate that the method can be successfully applied with acceptable recoveries to a broad range of target pesticides within a diverse range of food types.

  5. Determination of thymol in human plasma by automated headspace solid-phase microextraction-gas chromatographic analysis.

    PubMed

    Kohlert, Claudia; Abel, Gudrun; Schmid, Eleonora; Veit, Markus

    2002-02-01

    A reliable and sensitive method was developed for determination of thymol in human plasma by automated headspace solid-phase microextraction (SPME). After enzymatic cleavage of thymol sulfate thymol was extracted by a 65 microm polydimethylsiloxane-divinylbenzene crimped fiber (Supelco) after addition of sodium chloride and phosphoric acid (85%). Desorption of the fiber was performed in the injection port of a gas chromatograph at 220 degrees C (HP 5890; 50 m x 0.2 mm I.D., 0.2 microm HP Innowax capillary column; flame ionization detection). Fibers were used repeatedly up to 40 analysis. The recovery was 5% after 35 min of extraction. The calibration curve was linear in the range of 8.1-203.5 ng ml(-1) with a limit of quantitation (LOQ) of 8.1 ng ml(-1). The within-day and between-day precision and accuracy were < or = 20% at the LOQ and <15% at higher concentrations according to international guidelines for validation of bioanalytical methods. After administration of a thymol-containing herbal extract only thymol sulfate, no free thymol, could be detected in human plasma, thus analysis of thymol was after enzymatic cleavage of thymol sulfate. It is concluded that the newly developed automated method can be used in clinical trials on bioavailability and pharmacokinetics of thymol-containing herbal medicinal products. PMID:11863281

  6. A low-power pressure-and temperature-programmed separation system for a micro gas chromatograph.

    SciTech Connect

    Sacks, Richard D. (University of Michigan, Ann Arbor, MI); Robinson, Alex Lockwood (Advanced Sensor Technologies, Albuquerque, NM); Lambertus, Gordon R. (University of Michigan, Ann Arbor, MI); Potkay, Joseph A. (University of Michigan, Ann Arbor, MI); Wise, Kensall D. (University of Michigan, Ann Arbor, MI)

    2006-10-01

    This thesis presents the theory, design, fabrication and testing of the microvalves and columns necessary in a pressure- and temperature-programmed micro gas chromatograph ({micro}GC). Two microcolumn designs are investigated: a bonded Si-glass column having a rectangular cross section and a vapor-deposited silicon oxynitride (Sion) column having a roughly circular cross section. Both microcolumns contain integrated heaters and sensors for rapid, controlled heating. The 3.2 cm x 3.2 cm, 3 m-long silicon-glass column, coated with a non-polar polydimethylsiloxane (PDMS) stationary phase, separates 30 volatile organic compounds (VOCs) in less than 6 min. This is the most efficient micromachined column reported to date, producing greater than 4000 plates/m. The 2.7 mm x 1.4 mm Sion column eliminates the glass sealing plate and silicon substrate using deposited dielectrics and is the lowest power and fastest GC column reported to date; it requires only 11 mW to raise the column temperature by 100 C and has a response time of 11s and natural temperature ramp rate of 580 C/min. A 1 m-long PDMS-coated Sion microcolumn separates 10 VOCs in 52s. A system-based design approach was used for both columns.

  7. Fast gas chromatographic residue analysis in animal feed using split injection and atmospheric pressure chemical ionisation tandem mass spectrometry.

    PubMed

    Tienstra, M; Portolés, T; Hernández, F; Mol, J G J

    2015-11-27

    Significant speed improvement for instrumental runtime would make GC–MS much more attractive for determination of pesticides and contaminants and as complementary technique to LC–MS. This was the trigger to develop a fast method (time between injections less than 10 min) for the determination of pesticides and PCBs that are not (or less) amenable to LC–MS. A key factor in achieving shorter analysis time was the use of split injection (1:10) which allowed the use of a much higher initial GC oven temperature. A shorter column (15 m), higher temperature ramp, and higher carrier gas flow rate (6 mL/min) further contributed to analysis-time reduction. Chromatographic resolution was slightly compromised but still well fit-for-purpose. Due to the high sensitivity of the technique used (GC–APCI-triple quadrupole MS/MS), quantification and identification were still possible down to the 10 μg/kg level, which was demonstrated by successful validation of the method for complex feed matrices according to EU guidelines. Other advantages of the method included a better compatibility of acetonitrile extracts (e.g. QuEChERS) with GC, and a reduced transfer of co-extractants into the GC column and mass spectrometer.

  8. Gas chromatographic separation of stereoisomers of non-protein amino acids on modified γ-cyclodextrin stationary phase.

    PubMed

    Fox, Stefan; Strasdeit, Henry; Haasmann, Stephan; Brückner, Hans

    2015-09-11

    Stereoisomers (enantiomers and diastereoisomers) of synthetic, non-protein amino acids comprising α-, β-, and γ-amino acids, including α,α-dialkyl amino acids, were converted into the respective N-trifluoroacetyl-O-methyl esters and analyzed and resolved by gas chromatography (GC) on a commercial fused silica capillary column coated with the chiral stationary phase octakis(3-O-butyryl-2,6-di-O-pentyl)-γ-cyclodextrin. This column is marketed under the trade name Lipodex(®) E. Chromatograms, retention times, and a chart displaying the retention times of approximately 40 stereoisomers of amino acids are presented. With few exceptions, baseline or almost baseline resolution was achieved for enantiomers and diastereoisomers. The chromatographic method presented is considered to be highly suitable for the elucidation of the stereochemistry of non-protein amino acids, for example in natural products, and for evaluating the enantiopurity of genetically non-coded amino acids used for the synthesis and design of conformationally tailored peptides. The method is applicable to extraterrestrial materials or can be used in experimental work related to abiotic syntheses or enantioselective destruction and amplification of amino acids.

  9. Gas-liquid chromatographic determination of 3-trifluoromethyl-4-nitrophenol residues in fish

    USGS Publications Warehouse

    Allen, J.L.; Sills, J.B.

    1974-01-01

    A procedure for the determination of 3-mftuormethyl-4-nitrophenol (TFM) in fish tissues is described. Homogenized tissues are extracted with hexane-ethyl ether; the extract is cleaned up by partitioning the TFM from the extracting solvent into O.IN NaOB, acidifying the aqueous solution, and partitioning again with hexaneethyl ether. The TFM is methylated with diazomethane and analyzed by gas-liquid chromatography, using electron capture detection. Recoveries ranged from 75 to 1000/., from fish muscles that were spiked with 0.01-2.00 JA#g TFM/g.

  10. Gas chromatographic determination of sorbitol, mannitol, and xylitol in chewing gum and sorbitol in mints.

    PubMed

    Daniels, D H; Warner, C R; Fazio, T

    1982-05-01

    A method has been developed for determination of sorbitol, mannitol, and xylitol in chewing gum and sorbitol in mints. Chewing gum is partitioned between methylene chloride and water; the mint is simply dissolved in water. The aqueous extract is dried and the residue is derivatized with pyridine-acetic anhydride to form the corresponding peracetates. The derivatives are quantitated by gas chromatography using a 9 ft x 2 mm column packed with 10% Silar 10C on Chromosorb W/AW. Average recoveries of these sugar alcohols ranged from 96 to 102%. PMID:6807952

  11. A charcoal sampling method and a gas chromatographic analytical procedure for carbon disulfide.

    PubMed

    McCammon, C S; Quinn, P M; Kupel, R E

    1975-08-01

    Research is reported concerning an acceptable method for sampling and analyzing samples for carbon disulfide. Test atmospheres of carbon disulfide were generated dynamically using the syringe injection method, ant the theoretical concetnration verified by a liquid absorbent, colorimetric method. The CS2 was adsorbed on charcoal tubes, eluted with benzene, and quantitated with a gas chromatography equipped with a sulfer flame photometric detector. The results compared with the colorimetris analysis. The sensitivity of this method is 1 mug on a charcoal tube. The charcoal tubes were also tested for breakthrough volumes, holding power vs time, and the effect of air transport and temperature cycles.

  12. Development of gas chromatographic methods for the analyses of organic carbonate-based electrolytes

    NASA Astrophysics Data System (ADS)

    Terborg, Lydia; Weber, Sascha; Passerini, Stefano; Winter, Martin; Karst, Uwe; Nowak, Sascha

    2014-01-01

    In this work, novel methods based on gas chromatography (GC) for the investigation of common organic carbonate-based electrolyte systems are presented, which are used in lithium ion batteries. The methods were developed for flame ionization detection (FID), mass spectrometric detection (MS). Further, headspace (HS) sampling for the investigation of solid samples like electrodes is reported. Limits of detection are reported for FID. Finally, the developed methods were applied to the electrolyte system of commercially available lithium ion batteries as well as on in-house assembled cells.

  13. Gas chromatographic-mass spectrometric assay for 6-hydroxymelatonin sulfate and 6-hydroxymelatonin glucuronide in urine

    SciTech Connect

    Francis, P.L.; Leone, A.M.; Young, I.M.; Stovell, P.; Silman, R.E.

    1987-04-01

    Circulating melatonin is hydroxylated to 6-hydroxymelatonin and excreted in urine as the sulfate and glucuronide conjugates. We extracted these two compounds from urine by using octadecylsilane-bonded silica cartridges to eliminate most of the urea and electrolytes, and silica cartridges to separate the sulfate and glucuronide conjugates. After hydrolyzing the separated conjugates enzymically, we determined the free hydroxymelatonin by gas chromatography-mass spectrometry. Though recoveries were low and variable, we were able to quantify the analyte in the original sample by adding deuterated sulfate and glucuronide conjugates to the urines before extraction.

  14. Simultaneous stratospheric gas and aerosol retrievals from broadband infrared occultation measurements.

    PubMed

    Oshchepkov, Sergey; Sasano, Yasuhiro; Yokota, Tatsuya; Uemura, Nobuyuki; Matsuda, Hisashi; Itou, Yasuhiro; Nakajima, Hideaki

    2005-08-01

    The inversion method for simultaneous gas (O3, NO2, HNO3, N2O, CH4, H2O, CFC-11, CFC-12, N2O5, and ClONO2) and aerosol retrievals from broadband continuous IR spectra of occultation measurements is described. Both gas and aerosol physical modeling with consideration of the multicomponent character of aerosol and polar stratospheric clouds (PSCs) are used to minimize the difference between measured and modeled transmittance spectra under smoothness constraints imposed on particle-size distributions for each PSC component and positive constraints on all gas and aerosol parameters. The method is tested by numerical simulations in which synthetic occultation measurements inherent to the improved limb atmospheric spectrometer are used. The study reveals that the method has significant advantages over other approaches based on offset or gas-window-channel aerosol correction for accurate gas retrievals and provides additional information on the particle-size composition, volume density, and chemical component character of PSCs.

  15. Miniaturized system of a gas chromatograph coupled with a Paul ion trap mass spectrometer

    NASA Technical Reports Server (NTRS)

    Shortt, B. J.; Darrach, M. R.; Holland, Paul M.; Chutjian, A.

    2005-01-01

    Miniature gas chromatography (GC) and miniature mass spectrometry (MS) instrumentation has been developed to identify and quantify the chemical compounds present in complex mixtures of gases. The design approach utilizes micro-GC components coupled with a Paul quadrupole ion trap (QIT) mass spectrometer. Inherent to the system are high sensitivity, good dynamic range, good QIT resolution, low GC flow-rates to minimize vacuum requirements and the need for consumables; and the use of a modular approach to adapt to volatile organic compounds dissolved in water or present in sediment. Measurements are reported on system response to gaseous species at concentrations varying over four orders of magnitude. The ability of the system to deal with complicated mixtures is demonstrated, and future improvements are discussed. The GC/QIT system described herein has a mass, volume and power that are, conservatively, one-twentieth of those of commercial off-the-shelf systems. Potential applications are to spacecraft cabin-air monitoring, robotic planetary exploration and trace-species detection for residual gas analysis and environmental monitoring.

  16. Gas chromatographic analysis of reactive carbonyl compounds formed from lipids upon UV-irradiation

    SciTech Connect

    Dennis, K.J.; Shibamoto, T. )

    1990-08-01

    Peroxidation of lipids produces carbonyl compounds; some of these, e.g., malonaldehyde and 4-hydroxynonenal, are genotoxic because of their reactivity with biological nucleophiles. Analysis of the reactive carbonyl compounds is often difficult. The methylhydrazine method developed for malonaldehyde analysis was applied to simultaneously measure the products formed from linoleic acid, linolenic acid, arachidonic acid, and squalene upon ultraviolet-irradiation (UV-irradiation). The photoreaction products, saturated monocarbonyl, alpha,beta-unsaturated carbonyls, and beta-dicarbonyls, were derivatized with methylhydrazine to give hydrazones, pyrazolines, and pyrazoles, respectively. The derivatives were analyzed by gas chromatography and gas chromatography-mass spectrometry. Lipid peroxidation products identified included formaldehyde, acetaldehyde, acrolein, malonaldehyde, n-hexanal, and 4-hydroxy-2-nonenal. Malonaldehyde levels formed upon 4 hr of irradiation were 0.06 micrograms/mg from squalene, 2.4 micrograms/mg from linolenic acid, and 5.7 micrograms/mg from arachidonic acid. Significant levels of acrolein (2.5 micrograms/mg) and 4-hydroxy-2-nonenal (0.17 micrograms/mg) were also produced from arachidonic acid upon 4 hr irradiation.

  17. Gas chromatographic determination of N-nitrosamines in beverages following automatic solid-phase extraction.

    PubMed

    Jurado-Sánchez, Beatriz; Ballesteros, Evaristo; Gallego, Mercedes

    2007-11-28

    A semiautomatic method for the determination of seven N-nitrosamines in beverages by gas chromatography with nitrogen-phosphorus detection is proposed. Beverage samples are aspirated into a solid-phase extraction module for preconcentration and cleanup. The influence of the experimental conditions was examined by using various sorbents among which LiChrolut EN was found to provide quantitative elution and the highest preconcentration factors of all. The proposed method is sensitive, with limits of detection between 7 and 33 ng/kg, and precise, with relative standard deviations from 4.3% to 6.0%. The recoveries of N-nitrosamines from beverage samples spiked with 0.5 or 1 microg/kg concentrations of these compounds ranged from 95% to 102%. The method was successfully applied to the determination of residues of the studied N-nitrosamines in beverages including beer, wine, liquor, whisky, cognac, rum, vodka, grape juice, cider, tonic water, and soft drinks. The analytes were only detected in beer samples, positives being confirmed by gas chromatography coupled with impact ionization mass spectrometry.

  18. Capillary column gas chromatographic determination of dicamba in water, including mass spectrometric confirmation.

    PubMed

    Jimenez, N C; Atallah, Y H; Bade, T R

    1989-01-01

    A sensitive method is described for determining dicamba at low micrograms/L levels in ground waters by capillary column gas chromatography with electron-capture detection (GC-EC); compound identity is confirmed by gas chromatography-mass spectrometry (GC-MS) using selected ion monitoring. Dicamba residue is hydrolyzed in KOH to form the potassium salt. The sample is then extracted with ethyl ether which is discarded. The aqueous phase is acidified to pH less than 1 and extracted twice with ethyl ether. The combined ethyl ether extracts are concentrated, and the residue is methylated using diazomethane to form the corresponding dicamba ester. The derivatized sample is cleaned up on a deactivated silica gel column. The methylated dicamba is separated on an SE-30 capillary column and quantitated by electron-capture or mass spectrometric detection. Average recoveries (X +/- SD) for ground water samples fortified with 0.40 microgram/L of dicamba are 86 +/- 5% by GC-EC and 97 +/- 7% by GC-MS detections. The EDL (estimated detection limit) for this method is 0.1 microgram dicamba/L water (ppb). PMID:2808247

  19. MOMA Gas Chromatograph-Mass Spectrometer onboard the 2018 ExoMars Mission: results and performance

    NASA Astrophysics Data System (ADS)

    Buch, A.; Pinnick, V. T.; Szopa, C.; Grand, N.; Humeau, O.; van Amerom, F. H.; Danell, R.; Freissinet, C.; Brinckerhoff, W.; Gonnsen, Z.; Mahaffy, P. R.; Coll, P.; Raulin, F.; Goesmann, F.

    2015-10-01

    The Mars Organic Molecule Analyzer (MOMA) is a dual ion source linear ion trap mass spectrometer that was designed for the 2018 joint ESA-Roscosmos mission to Mars. The main scientific aim of the mission is to search for signs of extant or extinct life in the near subsurface of Mars by acquiring samples from as deep as 2 m below the surface. MOMA will be a key analytical tool in providing chemical (molecular and chiral) information from the solid samples, with particular focus on the characterization of organic content. The MOMA instrument, itself, is a joint venture for NASA and ESA to develop a mass spectrometer capable of analyzing samples from pyrolysis/chemical derivatization gas chromatography (GC) as well as ambient pressure laser desorption ionization (LDI). The combination of the two analytical techniques allows for the chemical characterization of a broad range of compounds, including volatile and non-volatile species. Generally, MOMA can provide information on elemental and molecular makeup, polarity, chirality and isotopic patterns of analyte species. Here we report on the current performance of the MOMA prototype instruments, specifically the demonstration of the gas chromatographymass spectrometry (GC-MS) mode of operation.

  20. Characterization of thermal desorption with the Deans-switch technique in gas chromatographic analysis of volatile organic compounds.

    PubMed

    Ou-Yang, Chang-Feng; Huang, Ying-Xue; Huang, Ting-Jyun; Chen, Yong-Shen; Wang, Chieh-Heng; Wang, Jia-Lin

    2016-09-01

    This study presents a novel application based on the Deans-switch cutting technique to characterize the thermal-desorption (TD) properties for gas chromatographic (GC) analysis of ambient volatile organic compounds (VOCs). Flash-heating of the sorbent bed at high temperatures to desorb trapped VOCs to GC may easily produce severe asymmetric or tailing GC peaks affecting resolution and sensitivity if care is not taken to optimize the TD conditions. The TD peak without GC separation was first examined for the quality of the TD peak by analyzing a standard gas mixture from C2 to C12 at ppb level. The Deans switch was later applied in two different stages. First, it was used to cut the trailing tail of the TD peak, which, although significantly improved the GC peak symmetry, led to more loss of the higher boiling compounds than the low boiling ones, thus suggesting compound discrimination. Subsequently, the Deans switch was used to dissect the TD peak into six 30s slices in series, and an uneven distribution in composition between the slices were found. A progressive decrease in low boiling compounds and increase in higher boiling ones across the slices indicated severe inhomogeneity in the TD profile. This finding provided a clear evidence to answer the discrimination problem found with the tail cutting approach to improve peak symmetry. Through the use of the innovated slicing method based on the Deans-switch cutting technique, optimization of TD injection for highly resolved, symmetric and non-discriminated GC peaks can now be more quantitatively assessed and guided. PMID:27492597

  1. A new method for total OH reactivity measurements using a fast Gas Chromatographic Photo-Ionization Detector (GC-PID)

    NASA Astrophysics Data System (ADS)

    Nölscher, A. C.; Sinha, V.; Bockisch, S.; Klüpfel, T.; Williams, J.

    2012-05-01

    The primary and most important oxidant in the atmosphere is the hydroxyl radical (OH). Currently OH sinks, particularly gas phase reactions, are poorly constrained. One way to characterize the overall sink of OH is to measure directly the ambient loss rate of OH, the total OH reactivity. To date direct measurements of total OH reactivity have been either performed using a Laser Induced Fluorescence (LIF) system ("pump-and-probe" or "flow reactor") or the Comparative Reactivity Method (CRM) with a Proton Transfer Reaction Mass Spectrometer (PTR-MS). Both techniques require large, complex and expensive detection systems. This study presents a feasibility assessment for CRM total OH reactivity measurements using a new detector, a Gas Chromatographic Photo-Ionization Detector (GC-PID). Such a system is smaller, more portable, less power consuming and less expensive than other total OH reactivity measurement techniques. Total OH reactivity is measured by the CRM using a competitive reaction between a reagent (here pyrrole) with OH alone and in the presence of atmospheric reactive molecules. The new CRM method for total OH reactivity has been tested with parallel measurements of the GC-PID and the previously validated PTR-MS as detector for the reagent pyrrole during laboratory experiments, plant chamber and boreal field studies. Excellent agreement of both detectors was found when the GC-PID was operated under optimum conditions. Time resolution (60-70 s), sensitivity (LOD 3-6 s-1) and overall uncertainty (25% in optimum conditions) for total OH reactivity were equivalent to PTR-MS based total OH reactivity measurements. One drawback of the GC-PID system was the steady loss of sensitivity and accuracy during intensive measurements lasting several weeks, and a possible toluene interference. Generally, the GC-PID system has been shown to produce closely comparable results to the PTR-MS and thus in suitable environments (e.g. forests) it presents a viably economical

  2. Total OH reactivity measurements using a new fast Gas Chromatographic Photo-Ionization Detector (GC-PID)

    NASA Astrophysics Data System (ADS)

    Nölscher, A. C.; Sinha, V.; Bockisch, S.; Klüpfel, T.; Williams, J.

    2012-12-01

    The primary and most important oxidant in the atmosphere is the hydroxyl radical (OH). Currently OH sinks, particularly gas phase reactions, are poorly constrained. One way to characterize the overall sink of OH is to measure directly the ambient loss rate of OH, the total OH reactivity. To date, direct measurements of total OH reactivity have been either performed using a Laser-Induced Fluorescence (LIF) system ("pump-and-probe" or "flow reactor") or the Comparative Reactivity Method (CRM) with a Proton-Transfer-Reaction Mass Spectrometer (PTR-MS). Both techniques require large, complex and expensive detection systems. This study presents a feasibility assessment for CRM total OH reactivity measurements using a new detector, a Gas Chromatographic Photoionization Detector (GC-PID). Such a system is smaller, more portable, less power consuming and less expensive than other total OH reactivity measurement techniques. Total OH reactivity is measured by the CRM using a competitive reaction between a reagent (here pyrrole) with OH alone and in the presence of atmospheric reactive molecules. The new CRM method for total OH reactivity has been tested with parallel measurements of the GC-PID and the previously validated PTR-MS as detector for the reagent pyrrole during laboratory experiments, plant chamber and boreal field studies. Excellent agreement of both detectors was found when the GC-PID was operated under optimum conditions. Time resolution (60-70 s), sensitivity (LOD 3-6 s-1) and overall uncertainty (25% in optimum conditions) for total OH reactivity were similar to PTR-MS based total OH reactivity measurements. One drawback of the GC-PID system was the steady loss of sensitivity and accuracy during intensive measurements lasting several weeks, and a possible toluene interference. Generally, the GC-PID system has been shown to produce closely comparable results to the PTR-MS and thus in suitable environments (e.g. forests) it presents a viably economical

  3. Gas chromatographic separation of fatty acid esters of cholesterol and phytosterols on an ionic liquid capillary column.

    PubMed

    Hammann, Simon; Vetter, Walter

    2015-12-15

    Steryl esters are high molecular weight compounds (600-700g/mol) regularly present as a minor lipid class in animal and plant lipids. Different sterol backbones (e.g., cholesterol, β-sitosterol and brassicasterol) which can be esterified with various fatty acids can result in highly complex steryl ester patterns in food samples. The gas chromatographic (GC) analysis of intact steryl esters is challenging, since high elution temperatures are required for their elution. On nonpolar GC phases, steryl esters with fatty acids with differing degree of unsaturation (e.g., oleate and linoleate) cannot be separated and there are only few polar columns available with sufficient temperature stability. In this study, we used gas chromatography with mass spectrometry (GC/MS) and analyzed intact steryl esters on a commercial room temperature ionic liquid (RTIL) column which was shortened to a length of 12m. The column separated the steryl esters both by total carbon number and by degree of unsaturation of the fatty acid. For instance, cholesteryl esters with stearic acid (18:0), oleic acid (18:1n-9), linoleic acid (18:2n-6) and α-linolenic acid (18:3n-3) could be resolved (R≥1.3) from each other. By analysis of synthesized standard substances, the elution orders for different steryl backbones and different fatty acids on a given sterol backbone could be determined. Analysis of spreads and plant oils allowed to determine retention times for 37 steryl esters, although a few co-elutions were observed. The ionic liquid column proved to be well-suited for the analysis of intact steryl esters.

  4. Potential for Measurement of Trace Volatile Organic Compounds in Closed Environments Using Gas Chromatograph/Differential Mobility Spectrometer

    NASA Technical Reports Server (NTRS)

    Limero, Thomas; Cheng, Patti

    2007-01-01

    For nearly 3.5 years, the Volatile Organic Analyzer (VOA) has routinely analyzed the International Space Station (ISS) atmosphere for a target list of approximately 20 volatile organic compounds (VOCs). Additionally, an early prototype of the VOA collected data aboard submarines in two separate trials. Comparison of the data collected on ISS and submarines showed a surprising similarity in the atmospheres of the two environments. Furthermore, in both cases it was demonstrated that the VOA data can detect hardware issues unrelated to crew health. Finally, it was also clear in both operations that the VOA s size and resource consumption were major disadvantages that would restrict its use in the future. The VOA showed the value of measuring VOCs in closed environments, but it had to be shrunk if it was to be considered for future operations in these environments that are characterized by cramped spaces and limited resources. The Sionex Microanalyzer is a fraction of the VOA s size and this instrument seems capable of maintaining or improving upon the analytical performance of the VOA. The two design improvements that led to a smaller, less complex instrument are the Microanalyzer s use of recirculated air as the gas chromatograph s carrier gas and a micromachined detector. Although the VOA s ion mobility spectrometer and the Microanalyzer s differential mobility spectrometer (DMS) are related detector technologies, the DMS was more amenable to micromachining. This paper will present data from the initial assessment of the Microanalyzer. The instrument was challenged with mixtures that simulated the VOCs typically detected in closed-environment atmospheres.

  5. Characterization of thermal desorption with the Deans-switch technique in gas chromatographic analysis of volatile organic compounds.

    PubMed

    Ou-Yang, Chang-Feng; Huang, Ying-Xue; Huang, Ting-Jyun; Chen, Yong-Shen; Wang, Chieh-Heng; Wang, Jia-Lin

    2016-09-01

    This study presents a novel application based on the Deans-switch cutting technique to characterize the thermal-desorption (TD) properties for gas chromatographic (GC) analysis of ambient volatile organic compounds (VOCs). Flash-heating of the sorbent bed at high temperatures to desorb trapped VOCs to GC may easily produce severe asymmetric or tailing GC peaks affecting resolution and sensitivity if care is not taken to optimize the TD conditions. The TD peak without GC separation was first examined for the quality of the TD peak by analyzing a standard gas mixture from C2 to C12 at ppb level. The Deans switch was later applied in two different stages. First, it was used to cut the trailing tail of the TD peak, which, although significantly improved the GC peak symmetry, led to more loss of the higher boiling compounds than the low boiling ones, thus suggesting compound discrimination. Subsequently, the Deans switch was used to dissect the TD peak into six 30s slices in series, and an uneven distribution in composition between the slices were found. A progressive decrease in low boiling compounds and increase in higher boiling ones across the slices indicated severe inhomogeneity in the TD profile. This finding provided a clear evidence to answer the discrimination problem found with the tail cutting approach to improve peak symmetry. Through the use of the innovated slicing method based on the Deans-switch cutting technique, optimization of TD injection for highly resolved, symmetric and non-discriminated GC peaks can now be more quantitatively assessed and guided.

  6. Validation of a QuEChERS-based gas chromatographic method for analysis of pesticide residues in Cassia angustifolia (senna).

    PubMed

    Tripathy, Vandana; Saha, Ajoy; Patel, Dilipkumar J; Basak, B B; Shah, Paresh G; Kumar, Jitendra

    2016-08-01

    A simple multi-residue method based on modified QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) approach was established for the determination of 17 organochlorine (OC), 15 organophosphorous (OP) and 7 synthetic pyrethroid (SP) pesticides in an economically important medicinal plant of India, Senna (Cassia angustifolia), by gas chromatography coupled to electron capture and flame thermionic detectors (GC/ECD/FTD) and confirmation of residues was done on gas chromatograph coupled with mass spectrometry (GC-MS). The developed method was validated by testing the following parameters: linearity, limit of detection (LOD), limit of quantification (LOQ), matrix effect, accuracy-precision and measurement uncertainty; the validation study clearly demonstrated the suitability of the method for its intended application. All pesticides showed good linearity in the range 0.01-1.0 μg mL(-1) for OCs and OPs and 0.05-2.5 μg mL(-1) for SPs with correlation coefficients higher than 0.98. The method gave good recoveries for most of the pesticides (70-120%) with intra-day and inter-day precision < 20% in most of the cases. The limits of detection varied from 0.003 to 0.03 mg kg(-1), and the LOQs were determined as 0.01-0.049 mg kg(-1). The expanded uncertainties were <30%, which was distinctively less than a maximum default value of ±50%. The proposed method was successfully applied to determine pesticide residues in 12 commercial market samples obtained from different locations in India. PMID:27153296

  7. Features of a micro-gas chromatograph equipped with enrichment device and microchip plasma emission detection (muPED) for air monitoring.

    PubMed

    Tienpont, Bart; David, Frank; Witdouck, Wim; Vermeersch, Dries; Stoeri, Herbert; Sandra, Pat

    2008-11-01

    A field portable gas chromatograph (GC) was constructed allowing the enrichment of organic solutes from air samples on a miniaturized chemical trap and the subsequent gas chromatographic analysis on a resistively heated capillary column. The heart of the system is an integrated chip-based plasma emission detector (muPED). As a non-selective detector, the sensitivity is similar to that of a flame ionization detector (FID). The detector shows good selectivity for phosphorus, sulfur and chlorine-containing compounds with relative selectivities of ca. 5 x 10(5) gP gC(-1), 50 gS gC(-1) and 10(2) gCl gC(-1). The lifetime of the plasma chip under air monitoring conditions exceeded 3000 analyses. PMID:18941680

  8. Gas-liquid chromatographic determination of kepone in field-collected avian tissues and eggs

    USGS Publications Warehouse

    Stafford, C.J.; Reichel, W.L.; Swineford, D.M.; Prouty, R.M.; Gay, M.L.

    1978-01-01

    A procedure is described for determining Kepone (decachlorooctahydro-1,3,4-metheno-2H-cyclobuta [cd] pentalene-2-one) residues in avian egg, liver, and tissue. Samples were extracted with benzene-isopropanol, and the extract was cleaned up with fuming H2SO4-concentrated H2SO4. Kepone was separated from organochlorine pesticides and polychlorinated biphenyls on a Florisil column and analyzed by electron capture gas-liquid chromatography (GLC). The average recovery from spiked tissues was 86%. The analyses performed on 14 bald eagle carcasses and livers, 3 bald eagle eggs, and 14 osprey eggs show measurable levels which indicate that Kepone accumulates in the tissues of fish-eating birds. Residues were confirmed by GLC-mass spectrometry.

  9. Liquid chromatographic analysis of a formulated ester from a gas-turbine engine test

    NASA Technical Reports Server (NTRS)

    Jones, W. R., Jr.; Morales, W.

    1983-01-01

    Size exclusion chromatography (SEC) utilizing mu-Bondagel and mu-Styragel columns with a tetrahydrofuran mobile phase was used to determine the chemical degradation of lubricant samples from a gas-turbine engine test. A MIL-L-27502 candidate, ester-based lubricant was run in a J57-29 engine at a bulk oil temperature of 216 C. In general, the analyses indicated a progressive loss of primary ester, additive depletion, and formation of higher molecular weight material. An oil sample taken at the conclusion of the test showed a reversal of this trend because of large additions of new oil. The high-molecular-weight product from the degraded ester absorbed strongly in the ultraviolet region at 254 nanometers. This would indicate the presence of chromophoric groups. An analysis of a similar ester lubricant from a separate high-temperature bearing test yielded qualitatively similar results.

  10. Gas-chromatographic analysis of Mars soil samples at Rocknest site with the SAM instrument onboard Curiosity

    NASA Astrophysics Data System (ADS)

    Cabane, Michel; Coll, Patrice; Szopa, Cyril; Coscia, David; Buch, Aranaud; Teinturier, Samuel; Navarro-gonzalez, Rafael; Gaboriaud, Alain; Mahaffy, Paul; MSL science Team

    2013-04-01

    Amongst the SAM suite of instruments [1], SAM-GC (Gas Chromatograph) is devoted to identify and quantify volatiles evolved from the thermal/chemical treatment of any soil sample collected by the Curiosity rover. The first soil samples analyzed with SAM were composed of sand collected at the Rocknest site. For their analysis, these samples were submitted to a pyrolysis at temperatures reaching about 900°C. For SAM-GC and GCMS analyses, different fractions of pyrolysates were collected at different temperature in the ambient-900°C range in order to discriminate potential different volatile fractions present in the solid sample. With the aim to search for potential organic molecules outgassed from the samples, a SAM-GC analytical channel composed of thermal-desorption injector and a MXT-CLP chromatographic column was used as it was designed for the separation of a wide range of volatile organic molecules. This channel is also equipped with a thermal conductivity detector (TCD) capable to detect the most abundant species (with abundances down to approximately 10-10 mol). It is thus complementary to the mass spectrometer detection for quantification of such species as this last instrument has not a linear response in this domain of high abundance, whereas it is significantly more sensitive than the TCD. The results obtained with this instrument for the analysis of Rocknest soil first show that the performances of SAM-GC are representative of those obtained during calibrations of the instrument in laboratory, as well as they are repeatable. Hence, the instrument performs nominally, making it the first GCMS running successfully on Mars since the Viking missions. Moreover, the complementarity of GC towards MS is also shown, either by allowing the quantification of the major species detected (as water), or by providing a chromatographic signal well resolved temporally which can be used to improve the QMS signal treatment. In the frame of research of organics, the SAM

  11. Gas-Chromatographic analysis of Mars soil samples with the SAM instrument onboard Curiosity - the 180 first sols

    NASA Astrophysics Data System (ADS)

    Szopa, C.; Cabane, M.; Coll, P.; Coscia, D.; Buch, A.; Teinturier, S.; Navarro-Gonzalez, R.; Goutail, J.-P.; Montaron, C.; Rigal, J.-B.; Poinsignon, P.; Guerrini, V.; Clerc, M.-S.; Meftah, M.; Soldani, L.; Mettetal, F.; Jerôme, M.; Philippon, C.; Galic, A.; Sablairolles, J.; Triqueneaux, S.; Chazot, D.; Toffolo, B.; Rakoto, F. Y.; Gaboriaud, A.; Mahaffy, P.

    2013-09-01

    Amongst the SAM suite of instruments [1], SAM-GC (Gas Chromatograph) is devoted to identify and quantify volatiles evolved from the thermal/chemical treatment of any soil sample collected by the Curiosity rover. The first soil samples analyzed with SAM were composed of sand collected at the Rocknest site, when the second site analyzed was a basin called "Yellowkive Bay". For their analysis, these samples were submitted to a pyrolysis at temperatures reaching about 900°C. For SAM-GC and GCMS analyses, different fractions of pyrolysates were collected at different temperature in the ambient-900°C range in order to discriminate potential different volatile fractions present in the solid sample. With the aim to search for potential organic molecules outgassed from the samples, a SAM-GC analytical channel composed of thermal-desorption injector and a MXT-CLP chromatographic column was used as it was designed for the separation of a wide range of volatile organic molecules. This channel is also equipped with a thermal conductivity detector (TCD) capable to detect the most abundant species (with abundances down to approximately 10-10 mol). It is thus complementary to the mass spectrometer detection for quantification of such species as this last instrument has not a linear response in this domain of high abundance, whereas it is significantly more sensitive than the TCD. The results obtained with this instrument first show that the performances of SAM-GC are representative of those obtained during calibrations of the instrument in laboratory, as well as they are repeatable. Hence, the instrument performs nominally, making it the first GCMS running successfully on Mars since the Viking missions. Moreover, the complementarity of GC towards MS is also shown, either by allowing the quantification ofthe major species detected (as water), or by providing a chromatographic signal well resolved temporally which can be used to improve the QMS signal treatment. In the frame of

  12. Modified ion source triple quadrupole mass spectrometer gas chromatograph for polycyclic aromatic hydrocarbon analyses.

    PubMed

    Anderson, Kim A; Szelewski, Michael J; Wilson, Glenn; Quimby, Bruce D; Hoffman, Peter D

    2015-11-01

    We describe modified gas chromatography electron-impact/triple-quadrupole mass spectrometry (GC-EI/MS/MS) utilizing a newly developed hydrogen-injected self-cleaning ion source and modified 9mm extractor lens. This instrument, with optimized parameters, achieves quantitative separation of 62 polycyclic aromatic hydrocarbons (PAHs). Existing methods historically limited rigorous identification and quantification to a small subset, such as the 16 PAHs the US EPA has defined as priority pollutants. Without the critical source and extractor lens modifications, the off-the-shelf GC-EI/MS/MS system was unsuitable for complex PAH analysis. Separations were enhanced by increased gas flow, a complex GC temperature profile incorporating multiple isothermal periods, specific ramp rates, and a PAH-optimized column. Typical determinations with our refined GC-EI/MS/MS have a large linear range of 1-10,000pgμl(-1) and detection limits of <2pgμl(-1). Included in the 62 PAHs, multiple-reaction-monitoring (MRM) mode enabled GC-EI/MS/MS identification and quantitation of several constituents of the MW 302 PAH isomers. Using calibration standards, values determined were within 5% of true values over many months. Standard curve r(2) values were typically >0.998, exceptional for compounds which are archetypally difficult. With this method benzo[a]fluorene, benzo[b]fluorene, benzo[c]fluorene were fully separated as was benzo[b]fluoranthene, benzo[k]fluoranthene, and benzo[j]fluoranthene. Chrysene and triphenylene, were sufficiently separated to allow accurate quantitation. Mean limits of detection (LODs) across all PAHs were 1.02±0.84pgμl(-1) with indeno[1,2,3-c,d] pyrene having the lowest LOD at 0.26pgμl(-1) and only two analytes above 2.0pgμl(-1); acenaphthalene (2.33pgμl(-1)) and dibenzo[a,e]pyrene (6.44pgμl(-1)).

  13. Modified ion source triple quadrupole mass spectrometer gas chromatograph for polycyclic aromatic hydrocarbon analyses

    PubMed Central

    Anderson, Kim A.; Szelewski, Michael J.; Wilson, Glenn; Quimby, Bruce D.; Hoffman, Peter D.

    2015-01-01

    We describe modified gas chromatography electron-impact/triple-quadrupole mass spectrometry (GC–EI/MS/MS) utilizing a newly developed hydrogen-injected self-cleaning ion source and modified 9 mm extractor lens. This instrument, with optimized parameters, achieves quantitative separation of 62 polycyclic aromatic hydrocarbons (PAHs). Existing methods historically limited rigorous identification and quantification to a small subset, such as the 16 PAHs the US EPA has defined as priority pollutants. Without the critical source and extractor lens modifications, the off-the-shelf GC–EI/MS/MS system was unsuitable for complex PAH analysis. Separations were enhanced by increased gas flow, a complex GC temperature profile incorporating multiple isothermal periods, specific ramp rates, and a PAH-optimized column. Typical determinations with our refined GC–EI/MS/MS have a large linear range of 1–10,000 pg μl−1 and detection limits of <2 pg μl−1. Included in the 62 PAHs, multiple-reaction-monitoring (MRM) mode enabled GC-EI/MS/MS identification and quantitation of several constituents of the MW 302 PAHs isomers. Using calibration standards, values determined were within 5% of true values over many months. Standard curve r2 values were typically >0.998, exceptional for compounds which are archetypally difficult. With this method benzo[a]fluorene, benzo[b]fluorene, benzo[c]fluorene were fully separated as was benzo[b]fluoranthene, benzo[k]fluoranthene, and benzo[j]fluoranthene. Chrysene and triphenylene, were sufficiently separated to allow accurate quantitation. Mean limits of detection (LODs) across all PAHs were 1.02 ± 0.84 pg μl−1 with indeno[1,2,3-c,d] pyrene having the lowest LOD at 0.26 pg μl−1 and only two analytes above 2.0 pg μl−1; acenaphthalene (2.33 pg μl−1) and dibenzo[a,e]pyrene (6.44 pg μl−1). PMID:26454790

  14. Modified ion source triple quadrupole mass spectrometer gas chromatograph for polycyclic aromatic hydrocarbon analyses.

    PubMed

    Anderson, Kim A; Szelewski, Michael J; Wilson, Glenn; Quimby, Bruce D; Hoffman, Peter D

    2015-11-01

    We describe modified gas chromatography electron-impact/triple-quadrupole mass spectrometry (GC-EI/MS/MS) utilizing a newly developed hydrogen-injected self-cleaning ion source and modified 9mm extractor lens. This instrument, with optimized parameters, achieves quantitative separation of 62 polycyclic aromatic hydrocarbons (PAHs). Existing methods historically limited rigorous identification and quantification to a small subset, such as the 16 PAHs the US EPA has defined as priority pollutants. Without the critical source and extractor lens modifications, the off-the-shelf GC-EI/MS/MS system was unsuitable for complex PAH analysis. Separations were enhanced by increased gas flow, a complex GC temperature profile incorporating multiple isothermal periods, specific ramp rates, and a PAH-optimized column. Typical determinations with our refined GC-EI/MS/MS have a large linear range of 1-10,000pgμl(-1) and detection limits of <2pgμl(-1). Included in the 62 PAHs, multiple-reaction-monitoring (MRM) mode enabled GC-EI/MS/MS identification and quantitation of several constituents of the MW 302 PAH isomers. Using calibration standards, values determined were within 5% of true values over many months. Standard curve r(2) values were typically >0.998, exceptional for compounds which are archetypally difficult. With this method benzo[a]fluorene, benzo[b]fluorene, benzo[c]fluorene were fully separated as was benzo[b]fluoranthene, benzo[k]fluoranthene, and benzo[j]fluoranthene. Chrysene and triphenylene, were sufficiently separated to allow accurate quantitation. Mean limits of detection (LODs) across all PAHs were 1.02±0.84pgμl(-1) with indeno[1,2,3-c,d] pyrene having the lowest LOD at 0.26pgμl(-1) and only two analytes above 2.0pgμl(-1); acenaphthalene (2.33pgμl(-1)) and dibenzo[a,e]pyrene (6.44pgμl(-1)). PMID:26454790

  15. Characterization of Atypical Off-Flavor Compounds in Natural Cork Stoppers by Multidimensional Gas Chromatographic Techniques.

    PubMed

    Slabizki, Petra; Fischer, Claus; Legrum, Charlotte; Schmarr, Hans-Georg

    2015-09-01

    Natural cork stoppers with sensory deviations other than the typical cork taint were subgrouped according to their sensory descriptions and compared with unaffected control cork stoppers. The assessment of purge and trap extracts obtained from corresponding cork soaks was performed by heart-cut multidimensional gas chromatography-olfactometry (MDGC-O). The identification of compounds responsible for atypical cork taint detected in MDGC-O was further supported with additional multidimensional GC analysis in combination with mass spectrometric detection. Geosmin and 2-methylisoborneol were mainly found in cork stoppers described as moldy and cellarlike; 3-isopropyl-2-methoxypyrazine and 3-isobutyl-2-methoxypyrazine were found in cork stoppers described with green attributes. Across all cork subgroups, the impact compound for typical cork taint, 2,4,6-trichloroanisole (TCA), was present and is therefore a good marker for cork taint in general. Another potent aroma compound, 3,5-dimethyl-2-methoxypyrazine (MDMP), was also detected in each subgroup, obviously playing an important role with regard to the atypical cork taint. Sensory deviations possibly affecting the wine could be generated by MDMP and its presence should thus be monitored in routine quality control.

  16. Gas chromatographic isolation of individual compounds from complex matrices for radiocarbon dating

    SciTech Connect

    Eglinton, T.I.; Aluwihare, L.I.; McNichol, A.P.; Bauer, J.E.; Druffel, E.R.M.

    1996-03-01

    This paper describes the application of a novel, practical approach for isolation of individual compounds from complex organic matrices for natural abundance radiocarbon measurement. This is achieved through the use of automated pereparative capillary gas chromatography (PCGC) to separate and recover sufficient quantities of individual target compounds for {sup 14}C analysis by accelerator mass spectrometry (AMS). We developed and tested this approach using a suite of samples (plant lipids, petroleums) whose ages spanned the {sup 14}C time scale and which contained a variety of compound types (fatty acids, sterols, hydrocarbons). Comparison of individual compound and bulk radiocarbon signatures for the isotopically homogeneous samples studied revealed that {Delta}{sup 14}C values generally agreed well ({+-}10%). Background contamination was assessed at each stage of the isolation procedure, and incomplete solvent removal prior to combustion was the only significant source of additional carbon. Isotope fractionation was addressed through compound-specific stable carbon isotopic analyses. Fractionation of isotopes during isolation of individual compounds was minimal (<5% for {delta}{sup 13}C), provided the entire peak was collected during PCGC. Trapping of partially coeluting peaks did cause errors, and these results highlight the importance of conducting stable carbon isotopic measurements of each trapped compound in concert with AMS for reliable radiocarbon measurements. 29 refs., 9 figs., 2 tabs.

  17. Determination of Milk Fat Adulteration with Vegetable Oils and Animal Fats by Gas Chromatographic Analysis.

    PubMed

    Kim, Jin-Man; Kim, Ha-Jung; Park, Jung-Min

    2015-09-01

    This study assessed the potential application of gas chromatography (GC) in detecting milk fat (MF) adulteration with vegetable oils and animal fats and of characterizing samples by fat source. One hundred percent pure MF was adulterated with different vegetable oils and animal fats at various concentrations (0%, 10%, 30%, 50%, 70%, and 90%). GC was used to obtain the fatty acid (FA) profiles, triacylglycerol (TG) contents, and cholesterol contents. The pure MF and the adulterated MF samples were discriminated based on the total concentrations of saturated FAs and on the 2 major FAs (oleic acid [C18:1n9c] and linoleic acid [C18:2n6c], TGs [C52 and C54], and cholesterol contents using statistical analysis to compared difference. These bio-markers enabled the detection of as low as 10% adulteration of non-MF into 100% pure MF. The study demonstrated the high potential of GC to rapidly detect MF adulteration with vegetable and animal fats, and discriminate among commercial butter and milk products according to the fat source. These data can be potentially useful in detecting foreign fats in these butter products. Furthermore, it is important to consider that several individual samples should be analyzed before coming to a conclusion about MF authenticity.

  18. Atomic emission detection for gas chromatographic analysis of nitrogen-containing herbicides in water.

    PubMed

    Olson, N L; Carrell, R; Cummings, R; Rieck, R; Reimer, S

    1995-01-01

    A gas chromatography-atomic emission detection (GC-AED) system was used to analyze nitrogen-containing herbicides. Two methods of sample preparation were used to demonstrate the system's applicability. Method 1 was U.S. Environmental Protection Agency (EPA) Method 507. Method 2 was a modification of EPA Method 507 using larger sample volumes and smaller extract volumes to yield compound detection levels 30 times lower than detection levels from method 1. Analysis of replicate reagent water spikes with method 1 gave analyte recoveries ranging from 82 to 107%, with standard deviations of recovery of not more than 6.7%. Method 2 gave recoveries ranging from 50 to 112%, with a standard deviation of recovery of not more than 33%. A loss in recovery and precision with method 2 compared with method 1 was attributed to loss of more volatile analytes during extract concentration. Selectivity was demonstrated with solvent spiked with fuel oil and atrazine. Response factors generated with the GC-AED system showed compound-independent elemental linearity for analytes. Relative standard deviations of not more than 5.34% were obtained for 3 elements tested: nitrogen, sulphur, and chlorine. An elemental calibration mixture was prepared to validate traditional methods of quantitation. Samples were analyzed for nitrogen-containing herbicides, which were quantitated with both an analyte calibration and an elemental calibration, and results were compared.

  19. Determination of Milk Fat Adulteration with Vegetable Oils and Animal Fats by Gas Chromatographic Analysis.

    PubMed

    Kim, Jin-Man; Kim, Ha-Jung; Park, Jung-Min

    2015-09-01

    This study assessed the potential application of gas chromatography (GC) in detecting milk fat (MF) adulteration with vegetable oils and animal fats and of characterizing samples by fat source. One hundred percent pure MF was adulterated with different vegetable oils and animal fats at various concentrations (0%, 10%, 30%, 50%, 70%, and 90%). GC was used to obtain the fatty acid (FA) profiles, triacylglycerol (TG) contents, and cholesterol contents. The pure MF and the adulterated MF samples were discriminated based on the total concentrations of saturated FAs and on the 2 major FAs (oleic acid [C18:1n9c] and linoleic acid [C18:2n6c], TGs [C52 and C54], and cholesterol contents using statistical analysis to compared difference. These bio-markers enabled the detection of as low as 10% adulteration of non-MF into 100% pure MF. The study demonstrated the high potential of GC to rapidly detect MF adulteration with vegetable and animal fats, and discriminate among commercial butter and milk products according to the fat source. These data can be potentially useful in detecting foreign fats in these butter products. Furthermore, it is important to consider that several individual samples should be analyzed before coming to a conclusion about MF authenticity. PMID:26265530

  20. Gas chromatographic analysis of histamine in mahi-mahi (Coryphaena hippurus).

    PubMed

    Antoine, Francis R; Wei, Cheng-I; Otwell, W Steve; Sims, Charlie A; Littell, Ramon C; Hogle, Amanda D; Marshall, Maurice R

    2002-08-14

    Several authors have studied histamine using gas chromatography (GC) as a tool for quantitation, but the methods used were not always suitable depending on the kind of food. Problems frequently cited include incomplete histamine elution from the columns and peak tailing. Histamine is of interest because it is the factor common to all cases of scombroid poisoning, it has physiological and biological activity, and it is a chemical indicator of fish quality. In this study a modified GC method was used to quantify histamine in mahi-mahi (Coryphaena hippurus). Mean recovery was 67% for the GC method, compared with 90% for the AOAC fluorometric method. There was a 0.96 correlation of the GC histamine values with those of the AOAC fluorometric method. A temperature program, splitless/split injection, and analyte cleanup were essential for GC properties. Histamine retention time was 8.2 min. The method allowed peak height to be used for quantitation and simultaneous analysis of cadaverine and putrescine. PMID:12166956

  1. Comparison of extraction methods and detection systems in the gas chromatographic analysis of volatile carbonyl compounds.

    PubMed

    Stashenko, E E; Ferreira, M C; Sequeda, L G; Martínez, J R; Wong, J W

    1997-08-29

    High-resolution gas chromatography (HRGC) with electron-capture detection (ECD), nitrogen-phosphorus detection (NPD), flame ionization detection (FID) or with mass spectrometry-selected ion monitoring (MS-SIM) was used in the analysis of volatile carbonyl compounds. Eighteen carbonyl compounds that are typically produced during lipid peroxidation were derivatized quantitatively with pentafluorophenylhydrazine (PFPH) at room temperature, to afford their corresponding water-insoluble hydrazones. These derivatives were extracted into non-polar phases by means of either liquid-liquid extraction (LLE) (hexane) or solid-phase extraction (SPE) on 3 ml C18 octadecyl-bonded phase cartridges. Detection limits of 10(-14) and 10(-12) mol/ml per aldehyde were achieved with the ECD and MS-SIM systems, respectively. The effects of extraction conditions on sensitivity and recovery were determined by performing parallel HRGC-ECD and HRGC-MS-SIM analyses of pentafluorophenylhydrazones of the eighteen compounds under study. Recoveries of 51.4-78.9 +/- 1.2-4.5 and 80.9-98.3 +/- 1.0-3.5% were obtained with LLE and SPE, respectively. The method was applied to the analysis of the volatile carbonyl compounds in various heated vegetable oils (corn, palm or sunflower) and to the analysis of volatile aldehydes in human urine. PMID:9335127

  2. A practical methodology to measure unbiased gas chromatographic retention factor vs. temperature relationships.

    PubMed

    Peng, Baijie; Kuo, Mei-Yi; Yang, Panhia; Hewitt, Joshua T; Boswell, Paul G

    2014-12-29

    Compound identification continues to be a major challenge. Gas chromatography-mass spectrometry (GC-MS) is a primary tool used for this purpose, but the GC retention information it provides is underutilized because existing retention databases are experimentally restrictive and unreliable. A methodology called "retention projection" has the potential to overcome these limitations, but it requires the retention factor (k) vs. T relationship of a compound to calculate its retention time. Direct methods of measuring k vs. T relationships from a series of isothermal runs are tedious and time-consuming. Instead, a series of temperature programs can be used to quickly measure the k vs. T relationships, but they are generally not as accurate when measured this way because they are strongly biased by non-ideal behavior of the GC system in each of the runs. In this work, we overcome that problem by using the retention times of 25 n-alkanes to back-calculate the effective temperature profile and hold-up time vs. T profiles produced in each of the six temperature programs. When the profiles were measured this way and taken into account, the k vs. T relationships measured from each of two different GC-MS instruments were nearly as accurate as the ones measured isothermally, showing less than two-fold more error. Furthermore, temperature-programmed retention times calculated in five other laboratories from the new k vs. T relationships had the same distribution of error as when they were calculated from k vs. T relationships measured isothermally. Free software was developed to make the methodology easy to use. The new methodology potentially provides a relatively fast and easy way to measure unbiased k vs. T relationships.

  3. Advances in the gas chromatographic determination of persistent organic pollutants in the aquatic environment.

    PubMed

    van Leeuwen, S P J; de Boer, J

    2008-04-01

    Environmental chemists have been challenged for over 30 years to analyse complex mixtures of halogenated organic pollutants like polychlorinated biphenyls (PCBs), polychlorinated alkanes (PCAs), polybrominated diphenyl ethers (PBDEs) and polychlorinated dibenzo-p-dioxins and polychlorinated furans (PCDD/Fs). Gas chromatography (GC) often proved to be the method of choice because of its high resolution. The recent developments in the field of comprehensive two-dimensional GC (GCxGC) show that this technique can provide much more information than conventional (single-column) GC. Large volume injection (e.g. by programmed temperature vaporiser, or on-column injection) can be employed for the injection of tens of microliters of sample extract, in that way substantially improving the detection limits. Electron-capture detection (ECD) is a sensitive detection method but unambiguous identification is not possible and misidentification easily occurs. Mass spectrometric (MS) detection substantially improves the identification and the better the resolution (as with MS/MS, time-of-flight (TOF) MS and high-resolution (HR)MS), the lower the chances of misidentification are. Unfortunately, this comes only with substantially higher investments and maintenance costs. Co-extracted lipids, sulphur and other interferences can disturb the GC separation and detection leading to unreliable results. Extraction, and more so, sample clean-up and fractionation, are crucial steps prior to the GC analysis of these pollutants. Recent developments in sample extraction and clean-up show that selective pressurised liquid extraction (PLE) is an effective and efficient extraction and clean-up technique that enables processing of multiple samples in less than 1h. Quality assurance tools such as interlaboratory studies and reference materials are very well established for PCDD/Fs and PCBs but the improvement of that infrastructure is needed for brominated flame retardants, PCAs and toxaphene. PMID

  4. Characterization of low-temperature cofired ceramic tiles as platforms for gas chromatographic separations.

    PubMed

    Darko, Ernest; Thurbide, Kevin B; Gerhardt, Geoff C; Michienzi, Joseph

    2013-06-01

    A gas chromatography (GC) column is fabricated within a low-temperature cofired ceramic (LTCC) tile, and its analytical properties are characterized. By using a dual-spiral design, a 100 μm wide square channel up to 15 m in length is produced within an 11 cm × 5.5 cm LTCC tile. The channel is dynamically coated with an OV-101 stationary phase that is cross-linked with dicumyl peroxide. While the uncoated LTCC tiles were able to separate a mixture of n-alkanes, the peak shapes were broad (base width of ~2 min) and tailing. In contrast to this, the coated LTCC tiles produced sharp (base width of ~8-10 s), symmetrical, well-resolved peaks for the same analytes. By using a 7.5 m long channel, about 15,000 plates were obtained for a dodecane test analyte. Further, the coated LTCC tiles were found to produce plate heights that were about 3-fold smaller than those obtained from a conventional capillary GC column of similar length, dimension, and coating operated under the same conditions. As a result, test analyte separations were slightly improved in the LTCC tiles, and their overall performance fared well. In terms of temperature programming, it was found that a series of n-alkanes separated on the LTCC tile provided a cumulative peak capacity of around 54 peaks when using C₈ to C₁₃ as analyte markers. Results indicate that LTCC tiles provide a viable and useful alternative platform for performing good quality GC separations.

  5. Comprehensive two-dimensional gas chromatographic separations with a temperature programmed microfabricated thermal modulator.

    PubMed

    Collin, William R; Nuñovero, Nicolas; Paul, Dibyadeep; Kurabayashi, Katsuo; Zellers, Edward T

    2016-04-29

    Comprehensive two-dimensional gas chromatography (GC×GC) with a temperature-programmed microfabricated thermal modulator (μTM) is demonstrated. The 0.78 cm(2), 2-stage μTM chip with integrated heaters and a PDMS coated microchannel was placed in thermal contact with a solid-state thermoelectric cooler and mounted on top of a bench scale GC. It was fluidically coupled through heated interconnects to an upstream first-dimension ((1)D) PDMS-coated capillary column and a downstream uncoated capillary or second-dimension ((2)D) PEG-coated capillary. A mixture of n-alkanes C6-C10 was separated isothermally and the full-width-at-half-maximum (fwhm) values of the modulated peaks were assessed as a function of the computer-controlled minimum and maximum stage temperatures of μTM, Tmin and Tmax, respectively. With Tmin and Tmax fixed at -25 and 100°C, respectively, modulated peaks of C6 and C7 had fwhm values<53 ms while the modulated peaks of C10 had a fwhm value of 1.3s, due to inefficient re-mobilization. With Tmin and Tmax fixed at 0 and 210°C, respectively, the fwhm value for the modulated C10 peaks decreased to 67 ms, but C6 and C7 exhibited massive breakthrough. By programming Tmin from -25 to 0°C and Tmax from 100 to 220°C, the C6 and C7 peaks had fwhm values≤50 ms, and the fwhm for C10 peaks remained<95 ms. Using the latter conditions for the GC×GC separation of a sample of unleaded gasoline yielded resolution similar to that reported with a commercial thermal modulator. Replacing the PDMS phase in the μTM with a trigonal-tricationic room temperature ionic liquid eliminated the bleed observed with the PDMS, but also reduced the capacity for several test compounds. Regardless, the demonstrated capability to independently temperature program this low resource μTM enhances its versatility and its promise for use in bench-scale GC×GC systems.

  6. Evaluation of a Gas Chromatograph-Differential Mobility Spectrometer for Potential Water Monitoring on the International Space Station

    NASA Technical Reports Server (NTRS)

    Wallace, William T.; Limero, Thomas F.; Gazda, Daniel B.; Macatangay, Ariel V.; Dwivedi, Prabha; Fernandez, Facundo M.

    2015-01-01

    Environmental monitoring for manned spaceflight has long depended on archival sampling, which was sufficient for short missions. However, the longer mission durations aboard the International Space Station (ISS) have shown that enhanced, real-time monitoring capabilities are necessary in order to protect both the crewmembers and the spacecraft systems. Over the past several years, a number of real-time environmental monitors have been deployed on the ISS. Currently, volatile organic compounds (VOCs) in the station air are monitored by the Air Quality Monitor (AQM), a small, lightweight gas chromatograph-differential mobility spectrometer. For water monitoring, real-time monitors are used for total organic carbon (TOC) and biocide analysis. No information on the actual makeup of the TOC is provided presently, however. An improvement to the current state of environmental monitoring could be realized by modifying a single instrument to analyze both air and water. As the AQM currently provides quantitative, compound-specific information for VOCs in air samples, this instrument provides a logical starting point to evaluate the feasibility of this approach. The major hurdle for this effort lies in the liberation of the target analytes from the water matrix. In this presentation, we will discuss our recent studies, in which an electro-thermal vaporization unit has been interfaced with the AQM to analyze target VOCs at the concentrations at which they are routinely detected in archival water samples from the ISS. We will compare the results of these studies with those obtained from the instrumentation routinely used to analyze archival water samples.

  7. Evaluation of two adsorbents for diffusive sampling and thermal desorption-gas chromatographic analysis of monoterpenes in air.

    PubMed

    Sunesson, A L; Sundgren, M; Levin, J O; Eriksson, K; Carlson, R

    1999-02-01

    Tube type samplers with two different adsorbents, Chromosorb 106 and Tenax TA, were evaluated by laboratory experiments and field tests for simultaneous diffusive sampling of alpha-pinene, beta-pinene and delta 3-carene and subsequent thermal desorption-gas chromatographic analysis. No statistically significant effects of exposure time, concentrations of monoterpenes or relative humidity were found for samplers with Chromosorb 106 when running a factorial design, with the exception of the adsorption of delta 3-carene, for which some weak effects were noted. Samplers with Tenax TA were affected by the sampling time as well as the concentration for all terpenes, with a strong interaction effect between these two factors. The terpenes showed good storage stability on both adsorbents. No effect of back-diffusion was noted when using Chromosorb 106, while Tenax TA showed some back-diffusion effects. The uptake rates, in ml min-1, for the terpenes on Chromosorb 106 were 0.36 for alpha-pinene, 0.36 for beta-pinene and 0.40 for delta 3-carene. The corresponding average values on Tenax TA were 0.30 for alpha-pinene, 0.32 for beta-pinene and 0.38 for delta 3-carene. The field validation proved that diffusive sampling on Chromosorb 106 agreed well with pumped sampling on charcoal for stationary samples, while the personal samples indicated a discrepancy of 25% between Chromosorb 106 and charcoal samples. Tenax TA generally gave lower results than Chromosorb 106 in all field samples. Samplers packed with Chromosorb 106 could be used to monitor terpene levels in workplaces such as sawmills. The major advantages with this method are the sampling procedure, which is simple to perform compared to other techniques, the easily automated analysis procedure and the possibility to reuse the samplers.

  8. Titan's organic aerosols: Molecular composition and structure of laboratory analogues inferred from pyrolysis gas chromatography mass spectrometry analysis

    NASA Astrophysics Data System (ADS)

    Morisson, Marietta; Szopa, Cyril; Carrasco, Nathalie; Buch, Arnaud; Gautier, Thomas

    2016-10-01

    Analogues of Titan's aerosols are of primary interest in the understanding of Titan's atmospheric chemistry and climate, and in the development of in situ instrumentation for future space missions. Numerous studies have been carried out to characterize laboratory analogues of Titan aerosols (tholins), but their molecular composition and structure are still poorly known. If pyrolysis gas chromatography mass spectrometry (pyr-GCMS) has been used for years to give clues about their chemical composition, highly disparate results were obtained with this technique. They can be attributed to the variety of analytical conditions used for pyr-GCMS analyses, and/or to differences in the nature of the analogues analyzed, that were produced with different laboratory set-ups under various operating conditions. In order to have a better description of Titan's tholin's molecular composition by pyr-GCMS, we carried out a systematic study with two major objectives: (i) exploring the pyr-GCMS analytical parameters to find the optimal ones for the detection of a wide range of chemical products allowing a characterization of the tholins composition as comprehensive as possible, and (ii) highlighting the role of the CH4 ratio in the gaseous reactive medium on the tholin's molecular structure. We used a radio-frequency plasma discharge to synthetize tholins with different concentrations of CH4 diluted in N2. The samples were pyrolyzed at temperatures covering the 200-700°C range. The extracted gases were then analyzed by GCMS for their molecular identification. The optimal pyrolysis temperature for characterizing the molecular composition of our tholins by GCMS analysis is found to be 600°C. This temperature choice results from the best compromise between the number of compounds released, the quality of the signal and the appearance of pyrolysis artifacts. About a hundred molecules are identified as pyrolysates. A common major chromatographic pattern appears clearly for all the

  9. Aerosols: Non-CO2 Non-Greenhouse Non-Gas Forcing

    NASA Astrophysics Data System (ADS)

    Schwartz, S. E.

    2005-05-01

    Tropospheric aerosols influence Earth's radiation budget and climate by scattering and absorbing solar radiation (direct effects) and by modifying the reflectivity and extent of clouds (indirect effects). While aerosol forcing is arguably less important from a policy perspective than greenhouse gas forcing because of the short residence times of these aerosols (about a week) compared to the lifetimes of the well mixed greenhouse gases (decades to centuries), knowledge of aerosol forcing over the industrial period is essential to empirical inference of Earth's climate sensitivity from temperature change over this period and to evaluation of the performance of climate model simulations over this period. Accuracy in global-average forcing by anthropogenic aerosols required for these purposes is estimated to be ~0.5 w m-2 [Schwartz, J. Air Waste Management Assoc. 54, 1351-1359 (2004)]. For an accumulation-mode (radius 50-1000 nm) scattering aerosol above a dark surface the forcing per optical depth (at 550 nm) during daylight hours for cloud-free sky is 50 to 100 W m-2. Such a forcing intensity implies, taking into account 50% nighttime and ~50% cloud cover, that global average optical depth of anthropogenic aerosol must be known to 0.02 - 0.04, an accuracy achievable by careful ground-based measurements, but which would be difficult to achieve globally because of high spatial and temporal variation. Top-of-atmosphere forcing for a given optical depth is sensitive also to single scattering albedo, size distribution (as manifested in asymmetry parameter, backscatter fraction, or Angstrom exponent) and surface reflectance; these sensitivities are examined here. It is necessary as well to determine the fraction of forcing that is due to anthropogenic aerosol. Similar considerations apply to aerosol indirect forcing, which depends to first approximation on the number concentration of cloud condensation nuclei as a function of applied supersaturation, which depends on the

  10. Distinct Patterns of Climate Response to Anthropogenic Aerosol Versus Greenhouse Gas Forcing

    NASA Astrophysics Data System (ADS)

    WANG, H.; Xie, S. P.; Liu, Q.

    2015-12-01

    Patterns of climate response to anthropogenic aerosols and well-mixed greenhouse gas (GHG) changes are investigated using eight models from Phase 5 of the Coupled Model Intercomparison Project. In the 20th century, the principal climate response patterns show both similarities and differences between aerosol and GHG runs. This paper focuses on distinct patterns of climate response to aerosol and GHG changes, while a recent companion study discussed the similarities. The GHG induced radiative forcing gives rise to amplified warming in the tropical upper troposphere and intensified mid-latitude jets in both hemispheres. However, for the anthropogenic aerosols, they are concentrated in the Northern Hemisphere and the temperature change shows a deep cooling structure in the troposphere around 40°N. Consistent with thermal wind balance, the cooling anchors a westerly acceleration to its south in aerosol runs. The response to aerosol induced inter-hemispheric asymmetry is also interpreted in terms of an anomalous Hadley circulation across the equator. Careful comparison indicates that the aerosol forcing dominates the Northern Hemisphere response in atmospheric circulation and precipitation, including a southward shift of the Inter Tropical Convergence Zone, the drying trend over the East Asia monsoon region, the southward shift of the East Asia westerly jet and the North Pacific cooling. The GHG forcing dominates the tropical Pacific rainfall increase mediated by the sea surface temperature pattern. Several climate response pattern indices are evaluated for the relative importance of aerosol and GHG forcing. The aerosol induced inter-hemisphere thermal contrast plays a key role in inducing climate response patterns that are quite different from the results in GHG runs.

  11. Transient Climate Impacts for Scenarios of Aerosol Emissions from Asia: A Story of Coal versus Gas

    NASA Astrophysics Data System (ADS)

    Grandey, B. S.; Cheng, H.; Wang, C.

    2014-12-01

    Projections of anthropogenic aerosol emissions are uncertain. In Asia, it is possible that emissions may increase if business continues as usual, with economic growth driving an increase in coal burning. But it is also possible that emissions may decrease rapidly due to the widespread adoption of cleaner technology or a shift towards non-coal fuels, such as natural gas. In this study, the transient climate impacts of three aerosol emissions scenarios are investigated: an RCP4.5 (Representative Concentration Pathway 4.5) control; a scenario with reduced Asian anthropogenic aerosol emissions; and a scenario with enhanced Asian anthropogenic aerosol emissions. A coupled atmosphere-ocean configuration of CESM (Community Earth System Model), including CAM5 (Community Atmosphere Model version 5), is used. Enhanced Asian aerosol emissions are found to delay global mean warming by one decade at the end of the century. Aerosol-induced suppression of the East Asian and South Asian summer monsoon precipitation occurs. The enhanced Asian aerosol emissions also remotely impact precipitation in other parts of the world: over the Sahel, West African monsoon precipitation is suppressed; and over Australia, austral summer monsoon precipitation is enhanced. These remote impacts on precipitation are associated with a southward shift of the ITCZ. The aerosol-induced sea surface temperature (SST) response appears to play an important role in the precipitation changes over South Asia and Australia, but not over East Asia. These results indicate that energy production in Asia, through the consequent aerosol emissions and associated radiative effects, might significantly influence future climate both locally and globally.

  12. Different responses of Sea Surface Temperature in the North Pacific to greenhouse gas and aerosol forcing

    NASA Astrophysics Data System (ADS)

    Wang, Liyi; Liu, Qinyu

    2015-12-01

    The responses of Sea Surface Temperature (SST) to greenhouse gas (GHG) and anthropogenic aerosol in the North Pacific are compared based on the historical single and all-forcing simulations with Geophysical Fluid Dynamics Laboratory Climate Model version 3 (GFDL CM3). During 1860-2005, the effect of GHG forcing on the North Pacific SST is opposite to that of the aerosol forcing. Specifically, the aerosol cooling effect exceeds the GHG warming effect in the Kuroshio Extension (KE) region during 1950-2004 in the CM3 single forcing. The mid-latitude response of ocean circulation to the GHG (aerosol) forcing is to enhance (weaken) the Subtropical Gyre. Then the SST warming (cooling) lies on the zonal band of 40°N because of the increased (reduced) KE warm advection effect in the GHG (aerosol) forcing simulations, and the cooling effect to SST will surpass the warming effect in the KE region in the historical all-forcing simulations. Besides, the positive feedback between cold SST and cloud can also strengthen the aerosol cooling effect in the KE region during boreal summer, when the mixed layer depth is shallow. In the GHG (aerosol) forcing simulations, corresponding to warming (cooling) SST in the KE region, the weakened (enhanced) Aleutian Low appears in the Northeast Pacific. Consequently, the SST responses to all-forcing in the historical simulations are similar to the responses to aerosol forcing in sign and spatial pattern, hence the aerosol effect is quite important to the SST cooling in the mid-latitude North Pacific during the past 55 years.

  13. Chemical analysis of aerosol in the Venusian cloud layer by reaction gas chromatography on board the Vega landers

    NASA Technical Reports Server (NTRS)

    Gelman, B. G.; Drozdov, Y. V.; Melnikov, V. V.; Rotin, V. A.; Khokhlov, V. N.; Bondarev, V. B.; Dolnikov, G. G.; Dyachkov, A. V.; Nenarokov, D. F.; Mukhin, L. M.

    1986-01-01

    The experiment on sulfuric acid aerosol determination in the Venusian cloud layer on board the Vega landers is described. An average content of sulfuric acid of approximately 1 mg/cu m was found for the samples taken from the atmosphere at heights from 63 to 48 km and analyzed with the SIGMA-3 chromatograph. Sulfur dioxide (SO2) was revealed in the gaseous sample at the height of 48 km. From the experimental results and blank run measurements, a suggestion is made that the Venusian cloud layer aerosol consists of more complicated particles than the sulfuric acid water solution does.

  14. Hybrid preconcentrator/focuser module for determinations of explosive marker compounds with a micro-scale gas chromatograph.

    PubMed

    Serrano, Gustavo; Sukaew, Thitiporn; Zellers, Edward T

    2013-03-01

    This article describes the development and characterization of a partially selective preconcentrator/focuser (PCF) module for a field-portable micro-scale gas chromatograph (μGC) designed to rapidly determine trace levels of two vapor-phase markers of the explosive trinitrotoluene (TNT): 2,3-dimethyl-2,3-dinitrobutane (DMNB) and 2,4-dinitrotoluene (2,4-DNT). The PCF module has three primary components. The first is a high-volume sampler, comprising a resistively-heated 6-cm long stainless steel tube packed with tandem beds of the graphitized carbons Carbopack B (C-B, 30 mg) and Carbopack Y (C-Y, 15 mg), which traps the markers but permits more volatile interferences to pass through largely unretained. The second component is a microfocuser (μF), comprising a 4.2×9.8 mm Si chip containing a deep-reactive-ion-etched (DRIE) cavity packed with 2mg of C-B, a Pyrex cap, integrated heaters, and etched fluidic channels. The third component is a commercial polymer-membrane filter used as a pre-trap to remove particles and adsorbed low volatility interferences. Markers captured in the sampler are thermally desorbed and transferred to the μF, and then thermally desorbed/injected from the μF into a downstream separation (micro)column and detected. Scrubbed ambient air is used as carrier gas. The adsorbent capacities, baseline temperatures, sampling and desorption flow rates, and heating profiles were optimized for each PCF module component while minimizing the analysis time. An overall transfer efficiency of 86% was achieved at marker concentrations of ~0.2-2.6 ppb. In the final configuration the PCF module requires just 60s to collect a 1-L sample (3 L/min), focus (40 mL/min), and inject the markers (3 mL/min), producing half-maximum injection peak widths of ~2 and 5 s, and preconcentration factors of 4500 and 1800, for DMNB and 2,4-DNT, respectively. PMID:23357747

  15. Aerodynamic design of gas and aerosol samplers for aircraft

    NASA Technical Reports Server (NTRS)

    Soderman, Paul T.; Hazen, Nathan L.; Brune, William H.

    1991-01-01

    The aerodynamic design of airborne probes for the capture of air and aerosols is discussed. Emphasis is placed on the key parameters that affect proper sampling, such as inlet-lip design, internal duct components for low pressure drop, and exhaust geometry. Inlet designs that avoid sonic flow conditions on the lip and flow separation in the duct are shown. Cross-stream velocities of aerosols are expressed in terms of droplet density and diameter. Flow curvature, which can cause aerosols to cross streamlines and impact on probe walls, can be minimized by means of a proper inlet shape and proper probe orientation, and by avoiding bends upstream of the test section. A NASA panel code called PMARC was used successfully to compute streamlines around aircraft and probes, as well as to compute to local velocity and pressure distributions in inlets. A NACA 1-series inlet with modified lip radius was used for the airborne capture of stratospheric chlorine monoxide at high altitude and high flight speed. The device has a two-stage inlet that decelerates the inflow with little disturbance to the flow through the test section. Diffuser design, exhaust hood design, valve loss, and corner vane geometry are discussed.

  16. Effect of bronchoconstrictive aerosols on pulmonary gas trapping in the A/J mouse.

    PubMed

    Yiamouyiannis, C A; Stengel, P W; Cockerham, S L; Silbaugh, S A

    1995-10-01

    We exposed A/J mice to several challenge aerosols and measured gas trapped within excised lungs by quantitating their buoyancy in saline (Archimedes' principle). The temporal stability of the excised lung gas volume (ELGV) measurement was also examined. ELGV increased in a dose proportional manner with increasing concentrations of methacholine and reached a maximum of 338 +/- 33% above vehicle-exposed controls. The A/J mice were 100 times more responsive to aerosol methacholine compared to hyporesponsive C3H/HeJ mice. Aerosol challenges of U-46619, a thromboxane A2 mimetic, and serotonin resulted in a 40% and 135% increase in ELGV's versus their controls, respectively. ELGV's were not increased after aerosols of leukotriene C4, histamine, substance P, N-formyl-methionyl-leucyl-phenyl-alanine and platelet activating factor. Both normal (filtered air-exposed) and hyperinflated (methacholine-exposed) excised lungs lost about 10% of their initial volume by 30 min and 40-65% of initial volume by 4 h. Occlusion of the trachea in either group did not affect the total gas lost, suggesting that majority of the gas loss was via transpleural diffusion. We conclude that determination of ELGV in mice, when performed soon after challenge testing, is a simple, rapid and reliable estimate of airway obstruction. PMID:8610213

  17. Direct gas chromatographic determination of the two isomeric insecticides, aldicarb and butocarboxime and their toxic metabolites: application to residue analysis in crops and leaves.

    PubMed

    Aharonson, N; Muszkat, L

    1985-02-01

    A gas-chromatographic method is described for determination of residues of butocarboxime (Drawin), its structural isomer aldicarb (Temik), and their toxic sulfoxide and sulfone metabolites. These compounds were determined intact, by gas chromatography employing a thermionic specific detector (TSD). Breakdown of these relatively thermally unstable compounds was avoided by lowering the inlet temperature to 150 degrees C, by keeping column temperature as low as possible, and by using a low-load liquid phase (2% of OV-17 on Gas-Chrom Q). These compounds were determined in enriched extracts of samples of tomatoes and apples and also in the leaves of citrus and cotton. The method is suitable for the separation, differentiation and determination of the two isomers and their metabolites at an enrichment level of 0.1 micrograms/g of fresh weight. The results were confirmed by gas chromatography--chemical-ionization mass-spectrometry. PMID:3984517

  18. Stratospheric Aerosol and Gas Experiment III on the International Space Station (SAGE III/ISS)

    NASA Technical Reports Server (NTRS)

    Gasbarre, Joseph; Walker, Richard; Cisewski, Michael; Zawodny, Joseph; Cheek, Dianne; Thornton, Brooke

    2015-01-01

    The Stratospheric Aerosol and Gas Experiment III on the International Space Station (SAGE III/ISS) mission will extend the SAGE data record from the ideal vantage point of the International Space Station (ISS). The ISS orbital inclination is ideal for SAGE measurements providing coverage between 70 deg north and 70 deg south latitude. The SAGE data record includes an extensively validated data set including aerosol optical depth data dating to the Stratospheric Aerosol Measurement (SAM) experiments in 1975 and 1978 and stratospheric ozone profile data dating to the Stratospheric Aerosol and Gas Experiment (SAGE) in 1979. These and subsequent data records, notably from the SAGE II experiment launched on the Earth Radiation Budget Satellite in 1984 and the SAGE III experiment launched on the Russian Meteor-3M satellite in 2001, have supported a robust, long-term assessment of key atmospheric constituents. These scientific measurements provide the basis for the analysis of five of the nine critical constituents (aerosols, ozone (O3), nitrogen dioxide (NO2), water vapor (H2O), and air density using O2) identified in the U.S. National Plan for Stratospheric Monitoring. SAGE III on ISS was originally scheduled to fly on the ISS in the same timeframe as the Meteor-3M mission, but was postponed due to delays in ISS construction. The project was re-established in 2009.

  19. Asian Monsoon Changes and the Role of Aerosol and Greenhouse Gas Forcing

    NASA Astrophysics Data System (ADS)

    Ting, M.; Li, X.

    2015-12-01

    Changes in Asian summer (June to August) monsoon in response to aerosol and greenhouse gas forcing are examined using observations and the Coupled Model Intercomparison Project - Phase 5 (CMIP5) multi-model, multi-realization ensemble. Results show that during the historical period, CMIP5 models show a predominantly drying trend in Asian monsoon, while in the 21st Century under representative concentration pathway 8.5 (rcp8.5) scenario, monsoon rainfall enhances across the entire Asian domain. The thermodynamic and dynamic mechanisms causing the changes are evaluated using the moisture budget analysis. The drying trend in the CMIP5 historical simulations and the wetting trend in the rcp8.5 projections can be explained by the relative importance of dynamical and thermodynamical contributions to the total moisture convergence. While thermodynamic mechanism dominates in the future, the historical rainfall changes are dominated by the changes in circulation. The relative contributions of aerosols and greenhouse gases (GHGs) on the historical monsoon change are further examined using CMIP5 single-forcing simulations. Rainfall reduces under aerosol forcing and increases under greenhouse gas (GHG) forcing. Aerosol forcing dominates over the greenhouse effect during the historical period, leading to the general drying trend in the all-forcing simulations. While the thermodynamic change of mean moisture convergence in the all-forcing case is dominated by the GHG forcing, the dynamic change in mean moisture convergence in the all-forcing case is dominated by the aerosol forcing. Further analysis using atmospheric GCM with prescribed aerosol and GHG radiative forcing versus those with the prescribed sea surface temperature (SST) warming suggests that the weak circulation changes due to GHG forcing is a result of the cancellation between CO2 radiative forcing and the SST warming, while aerosol radiative effect tends to enhance the circulation response due to SST forcing.

  20. Gas-liquid chromatographic detection an determination of diacetyl tartaric acid ester of diglyceride in dairy and nondairy coffee cream powders.

    PubMed

    Inoue, T; Iwaida, M; Ito, Y; Tonogai, Y

    1981-03-01

    Diacetyl tartaric acid ester of diglyceride was directly extracted from dairy or nondairy coffee cream powder under acidic conditions with ethyl acetate; then the extract was saponified with methanolic potash. After acidification with HCl, free fatty acid was removed with ether and the reaction mixture was absorbed on an anion exchange column. Tartaric acid was eluted with 2N HCl-acetone (1+1). An aliquot of the trimethylsilyl (TMS) derivative of the eluate was injected into a gas chromatograph with flame ionization detection, and a 1.5% SE-30 column. Recoveries of diacetyl tartaric acid ester of diglyceride at 50, 200, and 2000 ppm were 85.6-99.5%.

  1. The Stratospheric Aerosol and Gas Experiment (SAGE III) on the International Space Station (ISS) Mission

    NASA Technical Reports Server (NTRS)

    Cisewski, Michael; Zawodny, Joseph; Gasbarre, Joseph; Eckman, Richard; Topiwala, Nandkishore; Rodriquez-Alvarez, Otilia; Cheek, Dianne; Hall, Steve

    2014-01-01

    The Stratospheric Aerosol and Gas Experiment III on the International Space Station (SAGE III/ISS) mission will provide the science community with high-vertical resolution and nearly global observations of ozone, aerosols, water vapor, nitrogen dioxide, and other trace gas species in the stratosphere and upper-troposphere. SAGE III/ISS measurements will extend the long-term Stratospheric Aerosol Measurement (SAM) and SAGE data record begun in the 1970s. The multi-decadal SAGE ozone and aerosol data sets have undergone intense scrutiny and are considered the international standard for accuracy and stability. SAGE data have been used to monitor the effectiveness of the Montreal Protocol. Key objectives of the mission are to assess the state of the recovery in the distribution of ozone, to re-establish the aerosol measurements needed by both climate and ozone models, and to gain further insight into key processes contributing to ozone and aerosol variability. The space station mid-inclination orbit allows for a large range in latitude sampling and nearly continuous communications with payloads. The SAGE III instrument is the fifth in a series of instruments developed for monitoring atmospheric constituents with high vertical resolution. The SAGE III instrument is a moderate resolution spectrometer covering wavelengths from 290 nm to 1550 nm. Science data is collected in solar occultation mode, lunar occultation mode, and limb scatter measurement mode. A SpaceX Falcon 9 launch vehicle will provide access to space. Mounted in the unpressurized section of the Dragon trunk, SAGE III will be robotically removed from the Dragon and installed on the space station. SAGE III/ISS will be mounted to the ExPRESS Logistics Carrier-4 (ELC-4) location on the starboard side of the station. To facilitate a nadir view from this location, a Nadir Viewing Platform (NVP) payload was developed which mounts between the carrier and the SAGE III Instrument Payload (IP).

  2. AN INVESTIGATION OF THE RELATIONSHIP BETWEEN GAS-PHASE AND AEROSOL-BORNE HYDROPEROXIDES IN URBAN AIR. (R827352)

    EPA Science Inventory

    Simultaneous measurements of hydroperoxides in both the gas- and the aerosol-phase have been made for the first time. In addition, hydroperoxide levels in the ‘coarse’ (>PM2) and ‘fine’ (PM2) aerosol modes have been characteriz...

  3. Modelling non-equilibrium secondary organic aerosol formation and evaporation with the aerosol dynamics, gas- and particle-phase chemistry kinetic multilayer model ADCHAM

    SciTech Connect

    Roldin, P.; Eriksson, A. C.; Nordin, E. Z.; Hermansson, E.; Mogensen, Ditte; Rusanen, A.; Boy, Michael; Swietlicki, E.; Svenningsson, Birgitta; Zelenyuk, Alla; Pagels, J.

    2014-08-11

    We have developed the novel Aerosol Dynamics, gas- and particle- phase chemistry model for laboratory CHAMber studies (ADCHAM). The model combines the detailed gas phase Master Chemical Mechanism version 3.2, an aerosol dynamics and particle phase chemistry module (which considers acid catalysed oligomerization, heterogeneous oxidation reactions in the particle phase and non-ideal interactions between organic compounds, water and inorganic ions) and a kinetic multilayer module for diffusion limited transport of compounds between the gas phase, particle surface and particle bulk phase. In this article we describe and use ADCHAM to study: 1) the mass transfer limited uptake of ammonia (NH3) and formation of organic salts between ammonium (NH4+) and carboxylic acids (RCOOH), 2) the slow and almost particle size independent evaporation of α-pinene secondary organic aerosol (SOA) particles, and 3) the influence of chamber wall effects on the observed SOA formation in smog chambers.

  4. Aerosol deposition in the human lung periphery is increased by reduced-density gas breathing.

    PubMed

    Peterson, Jonathan B; Prisk, G Kim; Darquenne, Chantal

    2008-06-01

    Aerosol mixing resulting from turbulent flows is thought to be a major mechanism of deposition in the upper respiratory tract (URT). Because turbulence levels are a function of gas density, the use of a low-density carrier gas should reduce deposition in the URT allowing the aerosol to reach more peripheral airways of the lung. We performed aerosol bolus tests on 11 healthy subjects to investigate the effect of reduced gas density on regional aerosol deposition in the human lung. Using both air and heliox (80% helium, 20% oxygen) as carrier gas, boluses of 1 and 2 microm-diameter particles were inhaled to five volumetric lung depths (V(p)) between 150 and 1200 mL during an inspiration from residual volume (RV) to 1 liter above functional residual capacity at a constant flow rate of approximately 0.50 L/sec, which was immediately followed by an expiration to RV at the same flow rate. Aerosol deposition and axial dispersion were calculated from aerosol concentration and flow rate measured at the mouth. For 1 microm-diameter particles, deposition was significantly reduced by 29 +/- 28% (mean +/- SD, p < 0.05) when breathing heliox instead of air at shallow V(p) (150 mL) and significantly increased by 11 +/- 9% at deep V(p) (1200 mL). For 2 microm-diameter particles, deposition was significantly higher at V(p) = 500 mL by 6 +/- 7% and the predicted V(p) to achieve 100% deposition was significantly lower with heliox (834 +/- 146 mL) compared to air (912 +/- 128 mL) (p < 0.05). Despite a decrease in deposition at shallow V(p), there was no change in axial dispersion, suggesting that other factors such as radial turbulent mixing result in decreased aerosol deposition. Our results suggested that heliox reduces upper airway deposition of 1 and 2 microm-diameter particles allowing more particles to penetrate and subsequently deposit in the peripheral lung.

  5. Gas-particle partitioning of primary organic aerosol emissions: 3. Biomass burning

    NASA Astrophysics Data System (ADS)

    May, Andrew A.; Levin, Ezra J. T.; Hennigan, Christopher J.; Riipinen, Ilona; Lee, Taehyoung; Collett, Jeffrey L.; Jimenez, Jose L.; Kreidenweis, Sonia M.; Robinson, Allen L.

    2013-10-01

    organic aerosol concentrations depend in part on the gas-particle partitioning of primary organic aerosol (POA) emissions. Consequently, heating and dilution were used to investigate the volatility of biomass-burning smoke particles from combustion of common North American trees/shrubs/grasses during the third Fire Lab at Missoula Experiment. Fifty to eighty percent of the mass of biomass-burning POA evaporated when isothermally diluted from plume- (~1000 µg m-3) to ambient-like concentrations (~10 µg m-3), while roughly 80% of the POA evaporated upon heating to 100°C in a thermodenuder with a residence time of ~14 sec. Therefore, the majority of the POA emissions were semivolatile. Thermodenuder measurements performed at three different residence times indicated that there were not substantial mass transfer limitations to evaporation (i.e., the mass accommodation coefficient appears to be between 0.1 and 1). An evaporation kinetics model was used to derive volatility distributions and enthalpies of vaporization from the thermodenuder data. A single volatility distribution can be used to represent the measured gas-particle partitioning from the entire set of experiments, including different fuels, organic aerosol concentrations, and thermodenuder residence times. This distribution, derived from the thermodenuder measurements, also predicts the dilution-driven changes in gas-particle partitioning. This volatility distribution and associated emission factors for each fuel studied can be used to update emission inventories and to simulate the gas-particle partitioning of biomass-burning POA emissions in chemical transport models.

  6. Effects of ozone and sulfuric acid aerosol on gas trapping in the guinea pig lung

    SciTech Connect

    Silbaugh, S.A.; Mauderly, J.L.

    1986-01-01

    Four groups of 20 guinea pigs were sequentially exposed by inhalation to either air followed by sulfuric acid aerosol, ozone followed by sulfuric acid aerosol, ozone followed by air, or air followed by air to determine whether ozone preexposure sensitizes guinea pigs to the airway constrictive effects of sulfuric acid aerosol. All first exposures to ozone or air were 2 h in duration; all second exposures to sulfuric acid or air were for 1 h. All ozone and sulfuric acid exposures were 0.8 ppm and 12 mg/m3, respectively. Animals were observed for respiratory distress during exposure, and excised lungs were quantitated for trapped gas and wet/dry ratios. None of the guinea pigs developed dyspnea, and wet/dry ratios were not altered. Ozone significantly (p less than 0.05) increased trapped gas volumes, which were 44% (ozone-acid) to 68% (ozone-air) greater than in the air-air group. Trapped gas volume was 23% greater in the ozone-acid group than in the air-acid group, but the difference was not statistically significant (p less than 0.20). Thus, ozone increased gas trapping but did not significantly sensitize guinea pigs to the bronchoconstrictive action of sulfuric acid.

  7. Modeling Gas-Particle Partitioning of SOA: Effects of Aerosol Physical State and RH

    NASA Astrophysics Data System (ADS)

    Zuend, A.; Seinfeld, J.

    2011-12-01

    Aged tropospheric aerosol particles contain mixtures of inorganic salts, acids, water, and a large variety of organic compounds. In liquid aerosol particles non-ideal mixing of all species determines whether the condensed phase undergoes liquid-liquid phase separation or whether it is stable in a single mixed phase, and whether it contains solid salts in equilibrium with their saturated solution. The extended thermodynamic model AIOMFAC is able to predict such phase states by representing the variety of organic components using functional groups within a group-contribution concept. The number and composition of different condensed phases impacts the diversity of reaction media for multiphase chemistry and the gas-particle partitioning of semivolatile species. Recent studies show that under certain conditions biogenic and other organic-rich particles can be present in a highly viscous, semisolid or amorphous solid physical state, with consequences regarding reaction kinetics and mass transfer limitations. We present results of new gas-particle partitioning computations for aerosol chamber data using a model based on AIOMFAC activity coefficients and state-of-the-art vapor pressure estimation methods. Different environmental conditions in terms of temperature, relative humidity (RH), salt content, amount of precursor VOCs, and physical state of the particles are considered. We show how modifications of absorptive and adsorptive gas-particle mass transfer affects the total aerosol mass in the calculations and how the results of these modeling approaches compare to data of aerosol chamber experiments, such as alpha-pinene oxidation SOA. For a condensed phase in a mixed liquid state containing ammonium sulfate, the model predicts liquid-liquid phase separation up to high RH in case of, on average, moderately hydrophilic organic compounds, such as first generation oxidation products of alpha-pinene. The computations also reveal that treating liquid phases as ideal

  8. A water extraction, static headspace sampling, gas chromatographic method to determine MTBE in heating oil and diesel fuel.

    PubMed

    Cummins, T M; Robbins, G A; Henebry, B J; Goad, C R; Gilbert, E J; Miller, M E; Stuart, J D

    2001-03-15

    A method was developed to determine the fuel/water partition coefficient (KMTBE) of methyl tert-butyl ether (MTBE) and then used to determine low parts per million concentrations of MTBE in samples of heating oil and diesel fuel. A special capillary column designed for the separation of MTBE and to prevent coelution and a gas chromatograph equipped with a photoionization detector (PID) were used. MTBE was partitioned from fuel samples into water during an equilibration step. The water samples were then analyzed for MTBE using static headspace sampling followed by GC/PID. A mathematical relationship was derived that allowed a KMTBE value to be calculated by utilizing the fuel/water volume ratios and the corresponding PID signal. KMTBE values were found to range linearly from 3.8 to 10.9 over a temperature range of 5-40 degrees C. This analysis method gave a MDL of 0.7 ppm MTBE in the fuel and a relative average accuracy of +/-15% by comparison with an independent laboratory using purge and trap GC/ MS analysis. MTBE was found in home heating oil in residential tanks and in diesel fuel at service stations throughout the state of Connecticut. The levels of MTBE were found to vary significantly with time. Heating oil and diesel fuel from terminals were also found to contain MTBE. This research suggests thatthe reported widespread contamination of groundwater with MTBE may also be due to heating oil and diesel fuel releases to the environment. used extensively for the past 20 years as a gasoline additive (up to 15 wt %) to reduce automobile carbon monoxide and hydrocarbon emissions. The fact that MTBE is highly soluble in water (approximately 5 wt %) (3) and chemically inert when compared to other fuel constituents causes it to be often detected at high concentrations in groundwater in the vicinity of gasoline spills. The EPA has reported that low levels of MTBE in drinking water (above 40 microg/L) may cause unpleasant taste and odors and has designated MTBE as a

  9. Development and evaluation of the aerosol dynamics and gas phase chemistry model ADCHEM

    NASA Astrophysics Data System (ADS)

    Roldin, P.; Swietlicki, E.; Schurgers, G.; Arneth, A.; Lehtinen, K. E. J.; Boy, M.; Kulmala, M.

    2011-06-01

    The aim of this work was to develop a model suited for detailed studies of aerosol dynamics, gas and particle phase chemistry within urban plumes, from local scale (1 × 1 km2) to regional scale. This article describes and evaluates the trajectory model for Aerosol Dynamics, gas and particle phase CHEMistry and radiative transfer (ADCHEM). The model treats both vertical and horizontal dispersion perpendicular to an air mass trajectory (2-space dimensions). The Lagrangian approach enables a more detailed representation of the aerosol dynamics, gas and particle phase chemistry and a finer spatial and temporal resolution compared to that of available regional 3D-CTMs. These features make it among others well suited for urban plume studies. The aerosol dynamics model includes Brownian coagulation, dry deposition, wet deposition, in-cloud processing, condensation, evaporation, primary particle emissions and homogeneous nucleation. The organic mass partitioning was either modeled with a 2-dimensional volatility basis set (2D-VBS) or with the traditional two-product model approach. In ADCHEM these models consider the diffusion limited and particle size dependent condensation and evaporation of 110 and 40 different organic compounds respectively. The gas phase chemistry model calculates the gas phase concentrations of 61 different species, using 130 different chemical reactions. Daily isoprene and monoterpene emissions from European forests were simulated separately with the vegetation model LPJ-GUESS, and included as input to ADCHEM. ADCHEM was used to simulate the ageing of the urban plumes from the city of Malmö in southern Sweden (280 000 inhabitants). Several sensitivity tests were performed concerning the number of size bins, size structure method, aerosol dynamic processes, vertical and horizontal mixing, coupled or uncoupled condensation and the secondary organic aerosol formation. The simulations show that the full-stationary size structure gives accurate results

  10. Development and evaluation of the aerosol dynamic and gas phase chemistry model ADCHEM

    NASA Astrophysics Data System (ADS)

    Roldin, P.; Swietlicki, E.; Schurgers, G.; Arneth, A.; Lehtinen, K. E. J.; Boy, M.; Kulmala, M.

    2010-08-01

    The aim of this work was to develop a model ideally suited for detailed studies on aerosol dynamics, gas and particle phase chemistry within urban plumes, from local scale (1×1 km2) to regional or global scale. This article describes and evaluates the trajectory model for Aerosol Dynamics, gas and particle phase CHEMistry and radiative transfer (ADCHEM), which has been developed and used at Lund University since 2007. The model treats both vertical and horizontal dispersion perpendicular to an air mass trajectory (2-space dimensions), which is not treated in Lagrangian box-models (0-space dimensions). The Lagrangian approach enables a more detailed representation of the aerosol dynamics, gas and particle phase chemistry and a finer spatial and temporal resolution compared to that of available regional 3D-CTMs. These features make it among others ideally suited for urban plume studies. The aerosol dynamics model includes Brownian coagulation, dry deposition, wet deposition, in-cloud processing, condensation, evaporation, primary particle emissions and homogeneous nucleation. The gas phase chemistry model calculates the gas phase concentrations of 63 different species, using 119 different chemical reactions. Daily isoprene and monoterpene emissions from European forests were simulated separately with the vegetation model LPJ-GUESS, and included as input to ADCHEM. ADCHEM was used to simulate the ageing of the urban plumes from the city of Malmö in Southern Sweden (280 000 inhabitants). Several sensitivity tests were performed concerning the number of size bins, size structure method, coupled or uncoupled condensation, the volatility basis set (VBS) or traditional 2-product model for secondary organic aerosol formation, different aerosol dynamic processes and vertical and horizontal mixing. The simulations show that the full-stationary size structure gives accurate results with little numerical diffusion when more than 50 size bins are used between 1.5 and 2500 nm

  11. Determination of hexanal as an oxidative marker in vegetable oils using an automated dynamic headspace sampler coupled to a gas chromatograph/mass spectrometer.

    PubMed

    Ha, Jaeho; Seo, Dong-Won; Chen, Xi; Hwang, Jin-Bong; Shim, You-Shin

    2011-01-01

    An automated dynamic headspace sampler coupled to a gas chromatograph/mass spectrometer was evaluated as an oxidative marker to determine hexanal content in vegetable oils. For the effective analysis, a cooled injection system (CIS) was used to focus and to introduce the hexanal desorbed from the Tenax TA. The temperature of the CIS was maintained at -60 °C for 12 min before desorbing the hexanal. Hexanal was separated on a capillary column (DB-5, 0.25 mm × 60 m, 0.25 µm in film thickness) from 50 to 230 °C, followed by mass spectrometer-selected ion monitoring analysis at m/z 56. The instrumental response to hexanal was highly linear from 10 ng mL(-1) to 1 µg mL(-1) (r(2) = 0.9999). The relative standard deviation (RSD) of intra- and inter-day repeatability was acceptable, with values of less than 3.88 and 4.25%, respectively. The LOD and LOQ of hexanal were determined by gas chromatograph/mass spectrometer-selected ion monitoring to be 3.3 and 9.8 ng mL(-1), respectively. The acid value, peroxide value and fatty acid composition revealed a good correlation with the hexanal concentration.

  12. Simultaneous derivatisation and preconcentration of parabens in food and other matrices by isobutyl chloroformate and dispersive liquid-liquid microextraction followed by gas chromatographic analysis.

    PubMed

    Jain, Rajeev; Mudiam, Mohana Krishna Reddy; Chauhan, Abhishek; Ch, Ratnasekhar; Murthy, R C; Khan, Haider A

    2013-11-01

    A simple, rapid and economical method has been proposed for the quantitative determination of parabens (methyl, ethyl, propyl and butyl paraben) in different samples (food, cosmetics and water) based on isobutyl chloroformate (IBCF) derivatisation and preconcentration using dispersive liquid-liquid microextraction in single step. Under optimum conditions, solid samples were extracted with ethanol (disperser solvent) and 200 μL of this extract along with 50 μL of chloroform (extraction solvent) and 10 μL of IBCF was rapidly injected into 2 mL of ultra-pure water containing 150 μL of pyridine to induce formation of a cloudy state. After centrifugation, 1 μL of the sedimented phase was analysed using gas chromatograph-flame ionisation detector (GC-FID) and the peaks were confirmed using gas chromatograph-positive chemical ionisation-mass spectrometer (GC-PCI-MS). Method was found to be linear over the range of 0.1-10 μg mL(-1) with square of correlation coefficient (R(2)) in the range of 0.9913-0.9992. Limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.029-0.102 μg mL(-1) and 0.095-0.336 μg mL(-1) with a signal to noise ratio of 3:1 and 10:1, respectively.

  13. Simultaneous derivatisation and preconcentration of parabens in food and other matrices by isobutyl chloroformate and dispersive liquid-liquid microextraction followed by gas chromatographic analysis.

    PubMed

    Jain, Rajeev; Mudiam, Mohana Krishna Reddy; Chauhan, Abhishek; Ch, Ratnasekhar; Murthy, R C; Khan, Haider A

    2013-11-01

    A simple, rapid and economical method has been proposed for the quantitative determination of parabens (methyl, ethyl, propyl and butyl paraben) in different samples (food, cosmetics and water) based on isobutyl chloroformate (IBCF) derivatisation and preconcentration using dispersive liquid-liquid microextraction in single step. Under optimum conditions, solid samples were extracted with ethanol (disperser solvent) and 200 μL of this extract along with 50 μL of chloroform (extraction solvent) and 10 μL of IBCF was rapidly injected into 2 mL of ultra-pure water containing 150 μL of pyridine to induce formation of a cloudy state. After centrifugation, 1 μL of the sedimented phase was analysed using gas chromatograph-flame ionisation detector (GC-FID) and the peaks were confirmed using gas chromatograph-positive chemical ionisation-mass spectrometer (GC-PCI-MS). Method was found to be linear over the range of 0.1-10 μg mL(-1) with square of correlation coefficient (R(2)) in the range of 0.9913-0.9992. Limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.029-0.102 μg mL(-1) and 0.095-0.336 μg mL(-1) with a signal to noise ratio of 3:1 and 10:1, respectively. PMID:23768377

  14. Measurements of trace gas species and aerosols at three Siberian stations

    NASA Astrophysics Data System (ADS)

    Arshinov, Mikhail Yu.; Belan, Boris D.; Davydov, Denis K.; Kozlov, Artem V.; Ivlev, Georgii A.; Pestunov, Dmitrii A.; Tolmachev, Gennadii N.; Fofonov, Alexander V.

    2014-05-01

    Siberia is of great importance to understand the climate change due to it covers about 10% of Earth's land surface and it has the largest area to be studied under the Pan-Eurasian Experiment (PEEX). In the overview done by Kulmala et al. (2011) authors arrived at a conclusion that continuous and comprehensive measurements of GHGs and aerosols over Siberia are still lacking. Understanding the importance of this problem, in recent years the Institute of Atmospheric Optics SB RAS established several monitoring stations for continuous measurements of aerosol and trace gas species to fill up this gap. In this paper we present some results of continuous measurements of trace gas species and aerosols carried out at three stations located in West Siberia. The first one is a so-called TOR-station located in the scientific campus of Tomsk (56° 28'41"N, 85° 03'15"E), the second one is the Base Experimental Complex (BEC, 56° 28'49"N, 85° 06'08"E) - in the eastern suburbs of Tomsk, and the third one is Fonovaya Observatory (56° 25'07"N, 84° 04'27"E) - in a rural area 60 km west of Tomsk. All equipment of the stations is fully automated and can be monitored via Internet. Gas analyzers are hourly calibrated against standard gas mixtures, micro-flux gas sources, or gas generators, depending on the instrument type and the gas to be detected. Aerosol measurements carried out continuously from March 2010 enabled a frequency and seasonal dependency of the new particle formation (NPF) events to be revealed. NPF events in Siberia are more often observed during spring (from March to May) and early autumn (secondary frequency peak in September). On average, NPF evens took place on 23-28 % of all days. This work was funded by Presidium of RAS (Program No. 4), Brunch of Geology, Geophysics and Mining Sciences of RAS (Program No. 5), Interdisciplinary integration projects of Siberian Branch of RAS (No. 35, No. 70, No. 131), Russian Foundation for Basic Research (grants No 14

  15. A mobile remote sensing laboratory for water vapor, trace gas, aerosol, and wind speed measurements

    SciTech Connect

    Slaughter, D.; White, W.; Tulloch, W.; DeSlover, D.

    1993-03-19

    The Lawrence Livermore National Laboratory has developed a mobile field laboratory for remote measurement of atmospheric processes and observables that are important in global climate change, dispersal of hazardous materials, and atmospheric pollution. Specific observables of interest are water vapor, trace gases, aerosol size and density, wind, and temperature. The goal is to study atmospheric processes continuously for extended periods in remote field locations. This laboratory has just reached field ready status with sensors for aerosol and trace gas measurement based on established techniques. A development program is underway to enhance the sensor suite with several new techniques and instruments that are expected to significantly extend the state of the art in remote trace gas analysis. The new sensors will be incorporated into the lab during the next two years.

  16. Surface and Column Aerosol Impacts of the United States' Natural Gas Transition

    NASA Astrophysics Data System (ADS)

    Burney, J. A.

    2015-12-01

    This paper quantifies the air pollution and climate impacts of the natural gas transition over the past decade in the United States. We integrate satellite and ground measurements with chemical transport modeling to understand the impact of of the large-scale shift from coal to natural gas on the quantity and chemical composition of column aerosol and surface particulate matter. We leverage the natural experiment of individual units that changed technologies (a sharp discontinuity) as well as state-level changes from old plants being taken offline and new ones being brought online (a soft discontinuity) and connect technology changes to emissions changes to detected aerosol / particulate matter changes. We use this methodology to estimate the size of the 'sulfate' mask due to coal consumption in the United States and understand more fully the climate implications of energy technology changes.

  17. Prototype of the gas chromatograph - mass spectrometer to investigate volatile species in the lunar soil for the Luna-Glob and Luna-Resurs missions.

    NASA Astrophysics Data System (ADS)

    Hofer, L.; Lasi, D.; Tulej, M.; Wurz, P.; Cabane, M.; Cosica, D.; Gerasimov, M.; Rodinov, D.

    2013-09-01

    In preparation for the Russian Luna-Glob and Luna-Resurs missions we combined our compact time-offlight mass spectrometer (TOF-MS) with a chemical pre-separation of the species by gas chromatography (GC). Combined measurements with both instruments were successfully performed with the laboratory prototype of the mass spectrometer and a flight-like gas chromatograph. Due to its capability to record mass spectra over the full mass range at once with high sensitivity and a dynamic range of up to 106 within 1s, the TOF-MS system is a valuable extension of the GC analysis. The combined GC-MS complex is able to detect concentrations of volatile species in the sample of about 2·10^-9 by mass.

  18. Gas-particle partitioning of semivolatile organic compounds (SOCs) on mixtures of aerosols in a smog chamber.

    PubMed

    Chandramouli, Bharadwaj; Jang, Myoseon; Kamens, Richard M

    2003-09-15

    The partitioning behavior of a set of diverse SOCs on two and three component mixtures of aerosols from different sources was studied using smog chamber experimental data. A set of SOCs of different compound types was introduced into a system containing a mixture of aerosols from two or more sources. Gas and particle samples were taken using a filter-filter-denuder sampling system, and a partitioning coefficient Kp was estimated using Kp = Cp/(CgTSP). Particle size distributions were measured using a differential mobility analyzer and a light scattering detector. Gas and particle samples were analyzed using GCMS. The aerosol composition in the chamber was tracked chemically using a combination of signature compounds and the organic matter mass fraction (f(om)) of the individual aerosol sources. The physical nature of the aerosol mixture in the chamber was determined using particle size distributions, and an aggregate Kp was estimated from theoretically calculated Kp on the individual sources. Model fits for Kp showed that when the mixture involved primary sources of aerosol, the aggregate Kp of the mixture could be successfully modeled as an external mixture of the Kp on the individual aerosols. There were significant differences observed for some SOCs between modeling the system as an external and as an internal mixture. However, when one of the aerosol sources was secondary, the aggregate model Kp required incorporation of the secondary aerosol products on the preexisting aerosol for adequate model fits. Modeling such a system as an external mixture grossly overpredicted the Kp of alkanes in the mixture. Indirect evidence of heterogeneous, acid-catalyzed reactions in the particle phase was also seen, leading to a significant increase in the polarity of the resulting aerosol mix and a resulting decrease in the observed Kp of alkanes in the chamber. The model was partly consistent with this decrease but could not completely explain the reduction in Kp because of

  19. Interesting Scientific Questions Regarding Interactions in the Gas-aerosol-cloud System

    NASA Technical Reports Server (NTRS)

    Tabazadeh, Azadeh

    2002-01-01

    The growth of human population and their use of land, food and energy resources affect the Earth's atmosphere, biosphere and oceans in a complex manner. Many important questions in earth sciences today deal with issues regarding the impact of human activities on our immediate and future environment, ranging in scope from local (i.e. air pollution) to global (i.e. global warming) scale problems. Because the mass of the Earth's atmosphere is negligible compare to that found in the oceans and the biosphere, the atmosphere can respond quickly to natural and/or manmade perturbations. For example, seasonal 'ozone hole' formation in the Antarctic is a result of manmade CFC emissions in just the last 40 years. Also, the observed rise in global temperatures (known as global warming) is linked to a rapid increase in carbon dioxide and other greenhouse gas concentrations (emitted primarily by combustion processes) over the last century. The Earth's atmosphere is composed of a mixture of gases, aerosol and cloud particles. Natural and anthropogenic emissions of gases and aerosols affect the composition of the Earth's atmosphere. Changes in the chemical and physical makeup of the atmosphere can influence how the Earth will interact with the incoming solar radiation and the outgoing infrared radiation and vise versa. While, some perturbations are short-lived, others are long-lived and can affect the Earth's global climate and chemistry in many decades to come, In order to be able to separate the natural effects from anthropogenic ones, it is essential that we understand the basic physics and chemistry of interactions in the gas-aerosol-cloud system in the Earth's atmosphere. The important physics and chemistry that takes place in the coupled gas-aerosol-cloud system as it relates to aircraft observations are discussed.

  20. A rapid gas chromatographic injection-port derivatization method for the tandem mass spectrometric determination of patulin and 5-hydroxymethylfurfural in fruit juices.

    PubMed

    Marsol-Vall, Alexis; Balcells, Mercè; Eras, Jordi; Canela-Garayoa, Ramon

    2016-07-01

    A novel method consisting of injection-port derivatization coupled to gas chromatography-tandem mass spectrometry is described. The method allows the rapid assessment of 5-hydroxymethylfurfural (HMF) and patulin content in apple and pear derivatives. The chromatographic separation of the compounds was achieved in a short chromatographic run (12.2min) suitable for routine controls of these compounds in the fruit juice industry. The optimal conditions for the injection-port derivatization were at 270°C, 0.5min purge-off, and a 1:2 sample:derivatization reagent ratio (v/v). These conditions represent an important saving in terms of derivatization reagent consumption and sample preparation time. Quality parameters were assessed for the target compounds, giving LOD of 0.7 and 1.6μg/kg and LOQ of 2 and 5μg/kg for patulin and HMF, respectively. These values are below the maximum patulin concentration in food products intended for infants and young children. Repeatability (%RSD n=5) was below 12% for both compounds. In addition, the method linearity ranged between 25 and 1000μg/kg and between 5 and 192μg/kg for HMF and patulin, respectively. Finally, the method was applied to study HMF and patulin content in various fruit juice samples. PMID:27240947

  1. Gas chromatographic methods for determination of gamma-BHC in technical emulsifiable concentrates and water-dispersible powder formulations and in lindane shampoo and lotion: collaborative study.

    PubMed

    Miles, J W; Mount, D L; Beckmann, T J; Carrigan, S K; Galoux, I M; Hitos, P; Hodge, M C; Kissler, K; Martijn, A; Sanchez-Rasero, F

    1984-01-01

    Although the gas chromatographic separation of the isomers of BHC was demonstrated two decades ago, the present AOAC method of analysis of BHC for gamma-isomer (lindane) content is based on a separation carried out on a liquid chromatographic partition column. A method of analysis has been developed that uses an OV-210 column for separation of the gamma-isomer from the other isomers and impurities in technical BHC. Di-n-propyl phthalate was chosen as an internal standard. The same system allows quantitation of lindane in lotion and shampoo after these products are extracted with ethyl acetate-isooctane (1 + 4). The analytical methods were subjected to a collaborative trial with 10 laboratories. The coefficient of variation for technical BHC was 2.83%. For the water-dispersible powder and emulsifiable concentrate, the coefficients of variation were 2.89% and 4.62%, respectively. Coefficients of variation for 1% lindane lotion and shampoo were 4.36% and 11.92%, respectively. The method has been adopted official first action.

  2. Visibility-reducing organic aerosols in the vicinity of Grand Canyon National Park: Properties observed by high resolution gas chromatography

    SciTech Connect

    Mazurek, M. |; Masonjones, M.C.; Masonjones, H.D.; Salmon, L.G.; Cass, G.R.; Hallock, K.A.; Leach, M.

    1997-02-01

    Fine particle and total airborne particle samples were collected during August 1989 within the Grand Canyon [Indian Gardens (IG)] and on its south rim [Hopi Point (HP)] to define summertime organic aerosol concentration and composition as a function of elevation at Grand Canyon National Park. Inorganic chemical constituents were analyzed also to help place the relative importance of organics in perspective. Fine particle organic aerosols were approximately equal in concentration to sulfate aerosols at both sites. Monthly average mass concentrations for fine aerosol organics ranged from 1.1{mu}gm{sup {minus}3} (IG) to 1.3{mu}gm{sup {minus}3} (HP), while the organic aerosol concentration within total suspended particulate matter samples ranged from 1.9{mu}gm{sup {minus}3} (IG) to 2.1{mu}gm{sup {minus}3} (HP). Aerosol organics that could be evaluated by gas chromatography with flame ionization detection (GC-FID) (elutable organics) constituted 27{percent} to 53{percent} of the total organics mass collected as fine or total aerosol. At each site, roughly half of the elutable organics fine aerosol fraction was composed of highly polar organic compounds. Distributions of the elutable organics were compared to Los Angeles fine aerosol samples and to distributions of authentic sources of aerosol organics. It was found that the Grand Canyon organic aerosol during August 1989 did not resemble diluted aged Los Angeles organic aerosol, indicating that most of the organic particulate matter at the Grand Canyon at the time studied originated from other sources.{copyright} 1997 American Geophysical Union

  3. A Robust Computational Method for Coupled Liquid-liquid Phase Separation and Gas-particle Partitioning Predictions of Multicomponent Aerosols

    NASA Astrophysics Data System (ADS)

    Zuend, A.; Di Stefano, A.

    2014-12-01

    Providing efficient and reliable model predictions for the partitioning of atmospheric aerosol components between different phases (gas, liquids, solids) is a challenging problem. The partitioning of water, various semivolatile organic components, inorganic acids, bases, and salts, depends simultaneously on the chemical properties and interaction effects among all constituents of a gas + aerosol system. The effects of hygroscopic particle growth on the water contents and physical states of potentially two or more liquid and/or solid aerosol phases in turn may significantly affect multiphase chemistry, the direct effect of aerosols on climate, and the ability of specific particles to act as cloud condensation or ice nuclei. Considering the presence of a liquid-liquid phase separation in aerosol particles, which typically leads to one phase being enriched in rather hydrophobic compounds and the other phase enriched in water and dissolved electrolytes, adds a high degree of complexity to the goal of predicting the gas-particle partitioning of all components. Coupled gas-particle partitioning and phase separation methods are required to correctly account for the phase behaviour of aerosols exposed to varying environmental conditions, such as changes to relative humidity. We present new theoretical insights and a substantially improved algorithm for the reliable prediction of gas-particle partitioning at thermodynamic equilibrium based on the Aerosol Inorganic-Organic Mixtures Functional groups Activity Coefficients (AIOMFAC) model. We introduce a new approach for the accurate prediction of the phase distribution of multiple inorganic ions between two liquid phases, constrained by charge balance, and the coupling of the liquid-liquid equilibrium model to a robust gas-particle partitioning algorithm. Such coupled models are useful for exploring the range of environmental conditions leading to complete or incomplete miscibility of aerosol constituents which will affect

  4. The application of an improved gas and aerosol collector for ambient air pollutants in China

    NASA Astrophysics Data System (ADS)

    Dong, Huabin; Zeng, Limin; Zhang, Yuanhang; Hu, Min; Wu, Yusheng

    2016-04-01

    An improved Gas and Aerosol Collector (GAC) equipped with a newly designed aerosol collector and a set of dull-polished wet annular denuder (WAD) was developed by Peking University based on a Steam Jet Aerosol Collector (SJAC) sampler. Combined with Ion Chromatography (IC) the new sampler performed well in laboratory tests with high collection efficiencies for SO2 (above 98 %) and particulate sulfate (as high as 99.5 %). An inter-comparison between the GAC-IC system and the filter-pack method was performed and the results indicated that the GAC-IC system could supply reliable particulate sulfate, nitrate, chloride, and ammonium data in field measurement with a much wider range of ambient concentrations. From 2008 to 2015, dozens of big field campaigns (rural and coastal sites) were executed in different parts of China, the GAC-IC system took the chance having its field measurement performance checked repeatedly and provided high quality data in ambient conditions either under high loadings of pollutants or background area. Its measurements were highly correlated with data by other commercial instruments such as the SO2 analyzer, the HONO analyzer, a filter sampler, Aerosol Mass Spectrometer (AMS), etc. over a wide range of concentrations and proved particularly useful in future intensive campaigns or long-term monitoring stations to study various environmental issues such as secondary aerosol and haze formation. During these years of applications of GAC-IC in those field campaigns, we found some problems of several instruments running under field environment and some interesting results could also be drew from the large amount of data measured in near 20 provinces of China. Detail results will be demonstrated on the poster afterwards.

  5. Combination treatment of chlorine dioxide gas and aerosolized sanitizer for inactivating foodborne pathogens on spinach leaves and tomatoes.

    PubMed

    Park, Sang-Hyun; Kang, Dong-Hyun

    2015-08-17

    The objective of this study was to evaluate the antimicrobial effect of chlorine dioxide (ClO2) gas and aerosolized sanitizer, when applied alone or in combination, on the survival of Escherichia coli O157:H7, Salmonella Typhimurium, and Listeria monocytogenes inoculated onto spinach leaves and tomato surfaces. Spinach leaves and tomatoes were inoculated with a cocktail of three strains each of the three foodborne pathogens. ClO2 gas (5 or 10 ppmv) and aerosolized peracetic acid (PAA) (80 ppm) were applied alone or in combination for 20 min. Exposure to 10 ppmv of ClO2 gas for 20 min resulted in 3.4, 3.3, and 3.4 log reductions of E. coli O157:H7, S. Typhimurium, and L. monocytogenes on spinach leaves, respectively. Treatment with 80 ppm of aerosolized PAA for 20 min caused 2.3, 1.9, and 0.8 log reductions of E. coli O157:H7, S. Typhimurium, and L. monocytogenes, respectively. Combined treatment of ClO2 gas (10 ppmv) and aerosolized PAA (80 ppm) for 20 min caused 5.4, 5.1, and 4.1 log reductions of E. coli O157:H7, S. Typhimurium, and L. monocytogenes, respectively. E. coli O157:H7, S. Typhimurium, and L. monocytogenes on tomatoes experienced similar reduction patterns to those on spinach leaves. As treatment time increased, most combinations of ClO2 gas and aerosolized PAA showed additive effects in the inactivation of the three pathogens. Combined treatment of ClO2 gas and aerosolized PAA produced injured cells of three pathogens on spinach leaves while generally did not produce injured cells of these pathogens on tomatoes. Combined treatment of ClO2 gas (10 ppmv) and aerosolized PAA (80 ppm) did not significantly (p>0.05) affect the color and texture of samples during 7 days of storage.

  6. Combination treatment of chlorine dioxide gas and aerosolized sanitizer for inactivating foodborne pathogens on spinach leaves and tomatoes.

    PubMed

    Park, Sang-Hyun; Kang, Dong-Hyun

    2015-08-17

    The objective of this study was to evaluate the antimicrobial effect of chlorine dioxide (ClO2) gas and aerosolized sanitizer, when applied alone or in combination, on the survival of Escherichia coli O157:H7, Salmonella Typhimurium, and Listeria monocytogenes inoculated onto spinach leaves and tomato surfaces. Spinach leaves and tomatoes were inoculated with a cocktail of three strains each of the three foodborne pathogens. ClO2 gas (5 or 10 ppmv) and aerosolized peracetic acid (PAA) (80 ppm) were applied alone or in combination for 20 min. Exposure to 10 ppmv of ClO2 gas for 20 min resulted in 3.4, 3.3, and 3.4 log reductions of E. coli O157:H7, S. Typhimurium, and L. monocytogenes on spinach leaves, respectively. Treatment with 80 ppm of aerosolized PAA for 20 min caused 2.3, 1.9, and 0.8 log reductions of E. coli O157:H7, S. Typhimurium, and L. monocytogenes, respectively. Combined treatment of ClO2 gas (10 ppmv) and aerosolized PAA (80 ppm) for 20 min caused 5.4, 5.1, and 4.1 log reductions of E. coli O157:H7, S. Typhimurium, and L. monocytogenes, respectively. E. coli O157:H7, S. Typhimurium, and L. monocytogenes on tomatoes experienced similar reduction patterns to those on spinach leaves. As treatment time increased, most combinations of ClO2 gas and aerosolized PAA showed additive effects in the inactivation of the three pathogens. Combined treatment of ClO2 gas and aerosolized PAA produced injured cells of three pathogens on spinach leaves while generally did not produce injured cells of these pathogens on tomatoes. Combined treatment of ClO2 gas (10 ppmv) and aerosolized PAA (80 ppm) did not significantly (p>0.05) affect the color and texture of samples during 7 days of storage. PMID:26001524

  7. On the Stratospheric Aerosol and Gas Experiment III on the International Space Station

    NASA Technical Reports Server (NTRS)

    Hernandez, Gloria; Zawodny, Joseph M.; Cisewski, Michael S.; Thornton, Brooke M.; Panetta, Andrew D,; Roell, Marilee M.; Vernier, Jean-Paul

    2014-01-01

    The Stratospheric Aerosol and Gas Experiment III on International Space Station (SAGE3/ISS) is anticipated to be delivered to Cape Canaveral in the spring of 2015. This is the fourth generation, fifth instrument, of visible/near-IR solar occultation instruments operated by the National Aeronautics and Space Agency (NASA) to investigate the Earth's upper atmosphere. The instrument is a moderate resolution spectrometer covering wavelengths from 290 nm to 1550 nm. The nominal science products include vertical profiles of trace gases, such as ozone, nitrogen dioxide and water vapor, along with multi-wavelength aerosol extinction. The SAGE3/ISS validation program will be based upon internal consistency of the measurements, detailed analysis of the retrieval algorithm, and comparisons with independent correlative measurements. The Instrument Payload (IP), mission architecture, and major challenges are also discussed.

  8. Simple and rapid method for simultaneous gas chromatographic determination of bitertanol, metalaxyl, oxadixyl, propiconazole, and triadimefon residues in cucumbers.

    PubMed

    Lee, W O; Wong, S K

    1995-10-01

    A simple and rapid method for the determination of bitertanol, metalaxyl, oxadixyl, propiconazole and triadimefon residues in cucumbers has been developed. The fungicide residues were extracted from the sample with ethyl acetate and determined, after an automated gel permeation chromatographic clean-up, by GC with nitrogen-phosphorus detection. Cucumbers fortified with fungicides in the laboratory were analysed using the proposed method and that of Luke, Frooberg, Masumoto and Doose (J. Assoc. Off. Anal. Chem., 1981, 64, 1187). For the proposed method, mean recoveries ranged from 87.9% for bitertanol to 96.5% for oxadixyl. For the method of Luke et al. mean recoveries ranged from 79.8% for triadimefon to 97.8% for bitertanol. Cucumbers treated with the fungicides in the field were also analysed by these two methods. For the determination of all these five fungicides, no difference was observed at the 5% significance level.

  9. Multi-channel open tubular traps for headspace sampling, gas chromatographic fraction collection and olfactory assessment of milk volatiles.

    PubMed

    Naudé, Yvette; van Aardt, Marleen; Rohwer, Egmont Richard

    2009-04-01

    A headspace sampling method is described for concentrating milk volatiles onto a multi-channel open tubular silicone rubber trap (MCT) for thermal desorption into a GC-FID. Sections of the chromatographic profile, single peaks or combinations of compounds are recaptured with secondary MCTs during a subsequent run. The recaptured aroma is released in a controlled manner by heating the MCT in a portable heating device. An aroma release window of several minutes allows up to six people the opportunity to sniff each aroma fraction more than once. Olfactory results suggest that a synergistic combination of 2-heptanone and 2-nonanone could be responsible for a pungent cheese, sour milk-like aroma. MCTs containing single components or fractions can be desorbed into a GC-MS for compound identification.

  10. Expected trace gas and aerosol retrieval accuracy of the Geostationary Environment Monitoring Spectrometer

    NASA Astrophysics Data System (ADS)

    Jeong, U.; Kim, J.; Liu, X.; Lee, K. H.; Chance, K.; Song, C. H.

    2015-12-01

    The predicted accuracy of the trace gases and aerosol retrievals from the geostationary environment monitoring spectrometer (GEMS) was investigated. The GEMS is one of the first sensors to monitor NO2, SO2, HCHO, O3, and aerosols onboard geostationary earth orbit (GEO) over Asia. Since the GEMS is not launched yet, the simulated measurements and its precision were used in this study. The random and systematic component of the measurement error was estimated based on the instrument design. The atmospheric profiles were obtained from Model for Ozone And Related chemical Tracers (MOZART) simulations and surface reflectances were obtained from climatology of OMI Lambertian equivalent reflectance. The uncertainties of the GEMS trace gas and aerosol products were estimated based on the OE method using the atmospheric profile and surface reflectance. Most of the estimated uncertainties of NO2, HCHO, stratospheric and total O3 products satisfied the user's requirements with sufficient margin. However, about 26% of the estimated uncertainties of SO2 and about 30% of the estimated uncertainties of tropospheric O3 do not meet the required precision. Particularly the estimated uncertainty of SO2 is high in winter, when the emission is strong in East Asia. Further efforts are necessary in order to improve the retrieval accuracy of SO2 and tropospheric O3 in order to reach the scientific goal of GEMS. Random measurement error of GEMS was important for the NO2, SO2, and HCHO retrieval, while both the random and systematic measurement errors were important for the O3 retrievals. The degree of freedom for signal of tropospheric O3 was 0.8 ± 0.2 and that for stratospheric O3 was 2.9 ± 0.5. The estimated uncertainties of the aerosol retrieval from GEMS measurements were predicted to be lower than the required precision for the SZA range of the trace gas retrievals.

  11. Gas chromatographic-mass spectrometric characterization of all acyclic C5-C7 alkenes from fluid catalytic cracked gasoline using polydimethylsiloxane and squalane stationary phases.

    PubMed

    Soják, Ladislav; Addová, Gabriela; Kubinec, Róbert; Kraus, Angelika; Hu, Gengyuan

    2002-02-15

    Published retention indices of acyclic alkenes C5-C7 on squalane and polydimethylsiloxane as stationary phases were investigated, and reliable retention indices of alkenes from various sources were converted to separation systems used in a laboratory. Retention indices measured on available authentic commercial alkenes and on alkenic fraction of gasoline, published retention indices as well as means of GC-MS were used for verification of calculated retention indices. Retention of some gas chromatographic unseparated isomer pairs was obtained by mass spectrometric deconvolution using a specific single-ion monitoring. On the basis of these retention data, C5-C7 alkenes were identified and analyzed in the gasoline from fluid catalytic cracking. In the gasoline all 59 acyclic C5-C7 isomeric alkenes were determined at significantly different concentration levels.

  12. Stereometabolism of ethylbenzene in man: gas chromatographic determination of urinary excreted mandelic acid enantiomers and phenylglyoxylic acid and their relation to the height of occupational exposure.

    PubMed

    Korn, M; Gfrörer, W; Herz, R; Wodarz, I; Wodarz, R

    1992-01-01

    Ethylbenzene is an important industrial solvent and a key substance in styrene production. Ethylbenzene metabolism leads to the formation of mandelic acid, which occurs in two enantiomeric forms, and phenylglyoxylic acid. To decide which enantiomer is preferably formed, 70 urine samples of exposed workers were taken at the end of shifts and--after 3-pentyl ester derivatisation--gas chromatographically analysed. The R/S ratio of mandelic acid enantiomers in urine amounts to 19:1, which means that R-mandelic acid is a major metabolite and S-mandelic acid is one of the minor urinary metabolites of ethylbenzene in man. The R/S ratio is independent of ambient air concentration of ethylbenzene within the investigated range. Compared to an ethylbenzene monoexposure the height of total mandelic acid excretion is decreased in the case of coexposure to other aromatic solvents.

  13. Coupling of a gas chromatograph to a simultaneous-detection inductively coupled plasma mass spectrograph for speciation of organohalide and organometallic compounds

    SciTech Connect

    Barnes, James H.; Schilling, G; Sperline, Roger; Denton, M Bonner B.; Young, Erick T.; Barinaga, Charles J.; Koppenaal, David W.; Hieftje, Gary M.

    2004-06-01

    A gas chromatograph (GC) has been coupled to an inductively coupled plasma Mattauch-Herzog geometry mass spectrograph (ICP-MHMS) equipped with a novel detector array. In its current state of development the detector array, termed the focal plan camera (FPC), permits the simultaneous monitoring of up to 15 m/z values. A heated line was used to transfer the capillary-column effluent from the GC to the ICP torch, though due to instrument operating conditions, the transfer line was terminated 50 mm ahead of the ICP torch. Minimal tailing was observed, with the most severe effect seen for high-boiling analytes. With the coupling, absolute limits of detection are in the tens to hundreds of femtogram regime for organometallic species and in the single pictogram regime for halogenated hydrocarbons.

  14. Gas chromatographic determination of polycyclic aromatic hydrocarbons in water and smoked rice samples after solid-phase microextraction using multiwalled carbon nanotube loaded hollow fiber.

    PubMed

    Matin, Amir Abbas; Biparva, Pourya; Gheshlaghi, Mohammad

    2014-12-29

    A novel solid-phase microextraction fiber was prepared based on multiwalled carbon nanotubes (MWCNTs) loaded on hollow fiber membrane pores. Stainless steel wire was used as unbreakable support. The major advantages of the proposed fiber are its (a) high reproducibility due to the uniform structure of the hollow fiber membranes, (b) high extraction capacity related to the porous structure of the hollow fiber and outstanding adsorptive characteristics of MWCNTs. The proposed fiber was applied for the microextraction of five representative polycyclic aromatic hydrocarbons (PAHs) from aqueous media (river and hubble-bubble water) and smoked rice samples followed by gas chromatographic determination. Analytical merits of the method, including high correlation coefficients [(0.9963-0.9992) and (0.9982-0.9999)] and low detection limits [(9.0-13.0ngL(-1)) and (40.0-150.0ngkg(-1))] for water and rice samples, respectively, made the proposed method suitable for the ultra-trace determination of PAHs.

  15. Screening for volatile organic compounds in soil and groundwater by use of a portable gas chromatograph during field investigations at an Air Force installation in Ohio

    USGS Publications Warehouse

    Parnell, James M.

    1995-01-01

    The use of the portable gas chromatograph for screening of soil and water samples in the field was part of the drilling program for the installation of monitoring wells for a basewide ground-water monitoring program at Wright-Patterson Air Force Base, Ohio. Selected soil and ground-water samples were screened in the field for volatile organic compounds to determine if contamination was present, to define the vertical and lateral extent of contamination, and to aid in the placement of the well screens for optimal interception of contaminants. This report describes the screening methods, sample-collection, quality-assurance/quality-control methods, and data-interpretation procedures necessary for screening of soil and ground-water samples in the field during the water resources investigations.

  16. Characteristic chromatographic fingerprint study of short-chain fatty acids in human milk, infant formula, pure milk and fermented milk by gas chromatography-mass spectrometry.

    PubMed

    Jiang, Zhenzuo; Liu, Yanan; Zhu, Yan; Yang, Jing; Sun, Lili; Chai, Xin; Wang, Yuefei

    2016-09-01

    Human milk, infant formula, pure milk and fermented milk as food products or dietary supplements provide a range of nutrients required to both infants and adults. Recently, a growing body of evidence has revealed the beneficial roles of short-chain fatty acids (SCFAs), a subset of fatty acids produced from the fermentation of dietary fibers by gut microbiota. The objective of this study was to establish a chromatographic fingerprint technique to investigate SCFAs in human milk and dairy products by gas chromatography coupled with mass spectrometry. The multivariate method for principal component analysis assessed differences between milk types. Human milk, infant formula, pure milk and fermented milk were grouped independently, mainly because of differences in formic acid, acetic acid, propionic acid and hexanoic acid levels. This method will be important for the assessment of SCFAs in human milk and various dairy products.

  17. Comparison of nutshell granular activated carbons to commercial adsorbents for the purge-and-trap gas chromatographic analysis of volatile organic compounds.

    PubMed

    Wartelle, L H; Marshall, W E; Toles, C A; Johns, M M

    2000-05-26

    Granular activated carbons (GACs) made from agricultural by-products were investigated as adsorbents for short path thermal desorption gas chromatographic analysis of selected polar and nonpolar organic compounds. GACs made from macadamia nut, black walnut and hazelnut shells were compared to four commercially available adsorbents, namely, Tenax TA, Carboxen 569, Carbosieve SIII and coconut charcoal for their properties in purge-and-trap analysis. Adsorption values and breakthrough volumes were calculated for compounds from C3 and C6-C10. GACs derived from macadamia nut shells were found to adsorb and desorb between 80% (benzene) and 277% (ethylbenzene) more acetone (C3), benzene (C6), toluene (C7), ethyl- (C8), n-propyl- (C9), or sec.-butylbenzenes (C10) purged from water at the 100 ppb level than the commercial adsorbents tested. PMID:10893033

  18. The Composition of Titan's Lower Atmosphere and Simple Surface Volatiles as Measured by the Cassini-Huygens Probe Gas Chromatograph Mass Spectrometer Experiment

    NASA Technical Reports Server (NTRS)

    Niemann, H. B.; Atreya, S. K.; Demick, J. E.; Gautier, D.; Haberman, J. A.; Harpold, D. N.; Kasprzak, W. T.; Lunine, J. I.; Owen, T. C.; Raulin, F.

    2010-01-01

    The Cassini-Huygens Probe Gas Chromatograph Mass Spectrometer (GCMS) determined the composition of the Titan atmosphere from 140km altitude to the surface. After landing, it returned composition data of gases evaporated from the surface. Height profiles of molecular nitrogen (N2), methane (CH4) and molecular hydrogen (H2) were determined. Traces were detected on the surface of evaporating methane, ethane (C2H6), acetylene (C2H2), cyanogen (C2N2) and carbon dioxide (CO2). The methane data showed evidence that methane precipitation occurred recently. The methane mole fraction was (1.48+/-0.09) x 10(exp -2) in the lower stratosphere (139.8 km to 75.5 km) and (5.65+/-0.18) x 10(exp -2) near the surface (6.7 km to the surface). The molecular hydrogen mole fraction was (1.01+/-0.16) x 10(exp -3) in the atmosphere and (9.90+/-0.17) x 10(exp -4) on the surface. Isotope ratios were 167.7+/-0.6 for N-14/N-15 in molecular nitrogen, 91.1+/-1.4 for C-12/C-13 in methane and (1.35+/-0.30) x 10(exp -4) for D/H in molecular hydrogen. The mole fractions of Ar-36 and radiogenic Ar-40 are (2.1+/-0.8) x 10(exp -7) and (3.39 +/-0.12) x 10(exp -5) respectively. Ne-22 has been tentatively identified at a mole fraction of (2.8+/-2.1) x 10(exp -7) Krypton and xenon were below the detection threshold of 1 x 10(exp -8) mole fraction. Science data were not retrieved from the gas chromatograph subsystem as the abundance of the organic trace gases in the atmosphere and on the ground did not reach the detection threshold. Results previously published from the GCMS experiment are superseded by this publication.

  19. A multidimensional micro gas chromatograph employing a parallel separation multi-column chip and stop-flow μGC × μGCs configuration.

    PubMed

    Chen, Bo-Xun; Hung, Te-Yu; Jian, Rih-Sheng; Lu, Chia-Jung

    2013-04-01

    A dual-chip, multidimensional micro gas chromatographic module was designed, built and evaluated. Column chips were fabricated on a silicon wafer with an etched rectangular channel 100 μm (width) × 250 μm (depth) using a deep reactive ion etching (DRIE) process. The column chip for the first GC dimension was 3 m long and was coated with polydimethylsiloxane (DB-1) as the stationary phase. The columns on the second dimensional chip were etched with the same width and depth as the first chip, but the flow channel was split into three parallel columns, 1 m long, on the same sized silicon chip (i.e., 3 cm × 3 cm). These three parallel columns on the second chip were coated with polyethylene oxide (DB-Wax), trifluoropropylpolymethylsilicone (OV-210) and cyanopropylmethylphenylmethylpolysilicone (OV-225), accordingly, in order to provide diversified chromatographic retention. These two chips were connected via a stop-flow configuration to simultaneously generate multiple two-dimensional gas chromatograms for every analysis. This stop-flow μGC × μGCs design allowed the first column to function as a pre-separator and as a sequencing injector for the second parallel-separation chip. Fifteen volatile organic compounds with boiling points that ranged from 80-131 °C with various functional groups were tested using this μGC × μGCs module. Three discrete 2-D chromatograms were generated simultaneously, which demonstrated the advantages of simultaneously combining GC × GC with parallel separation GCs in microchip chromatography. The total traveling length in the column was only 4 m for each eluted peak and fully resolved separation was achieved through the cross reference among triplet 2-D chromatograms. PMID:23381092

  20. Evaluation of poly(90% biscyanopropyl/10% cyanopropylphenyl siloxane) capillary columns for the gas chromatographic quantification of trans fatty acids in non-hydrogenated vegetable oils.

    PubMed

    Delmonte, Pierluigi

    2016-08-19

    Current gas chromatographic (GC) methods for the analysis of fatty acids (FA) were optimized primarily for the quantification of the trans 18:1 FAs (18:1 tFAs) produced during the partial hydrogenation of fats and oils. Recent regulatory action regarding the application of partial hydrogenation in the processing of edible fats and oils may reshape the FA composition of these products. The higher content in 18:3 tFAs compared to 18:1 tFAs of most refined non-hydrogenated vegetable oils (RNHVO), and the challenge in their quantification applying current methods, suggest the need for new methodologies. This manuscript describes a simple GC method for the analysis of FAs in RNHVOs utilizing a 100m (0.25mm I.D.) capillary column coated with poly(90% biscyanopropyl/10% cyanopropylphenyl siloxane) (90% BCS). The optimization of the chromatographic conditions and the detection of co-eluting compounds were carried out by applying comprehensive two dimensional gas chromatography with online reduction (GC-OR×GC). Results showed that 90% BCS capillary columns operated at the elution temperature of 162°C provide the separation of the 18:1, 18:2 and 18:3 tFAs, contained in RNHVOs, from other components. A minor constituent of Canola oil, 16:3n-3, partially co-eluted with trans-18:1 FAMEs. This simple GC method showed the ability to measure trans-fat in RNHVOs at the level of 0.5g/100g, providing comparable quantitative results to the more complex GC×GC methodology.

  1. Evaluation of poly(90% biscyanopropyl/10% cyanopropylphenyl siloxane) capillary columns for the gas chromatographic quantification of trans fatty acids in non-hydrogenated vegetable oils.

    PubMed

    Delmonte, Pierluigi

    2016-08-19

    Current gas chromatographic (GC) methods for the analysis of fatty acids (FA) were optimized primarily for the quantification of the trans 18:1 FAs (18:1 tFAs) produced during the partial hydrogenation of fats and oils. Recent regulatory action regarding the application of partial hydrogenation in the processing of edible fats and oils may reshape the FA composition of these products. The higher content in 18:3 tFAs compared to 18:1 tFAs of most refined non-hydrogenated vegetable oils (RNHVO), and the challenge in their quantification applying current methods, suggest the need for new methodologies. This manuscript describes a simple GC method for the analysis of FAs in RNHVOs utilizing a 100m (0.25mm I.D.) capillary column coated with poly(90% biscyanopropyl/10% cyanopropylphenyl siloxane) (90% BCS). The optimization of the chromatographic conditions and the detection of co-eluting compounds were carried out by applying comprehensive two dimensional gas chromatography with online reduction (GC-OR×GC). Results showed that 90% BCS capillary columns operated at the elution temperature of 162°C provide the separation of the 18:1, 18:2 and 18:3 tFAs, contained in RNHVOs, from other components. A minor constituent of Canola oil, 16:3n-3, partially co-eluted with trans-18:1 FAMEs. This simple GC method showed the ability to measure trans-fat in RNHVOs at the level of 0.5g/100g, providing comparable quantitative results to the more complex GC×GC methodology. PMID:27470095

  2. The Lampedusa supersite of ChArMex: observing aerosol-radiation interactions and gas phase chemistry in the Mediterranean

    NASA Astrophysics Data System (ADS)

    Formenti, Paola; di Sarra, Alcide Giorgio

    2014-05-01

    Within the frame of the ADRIMED (Aerosol Direct Radiative Impact in the regional climate in the MEDiterranean region) project of the Chemistry-Aerosol Mediterranean experiment (ChArMex), the ENEA Laboratory for Climate Study "Roberto Sarao" (WMO/GAW/NDACC) on the Island of Lampedusa (35°31'N, 12°37°E) has been augmented to one of the supersites of the first phase of the Special Observing Period 1 by the measurements of the in situ properties of aerosols and trace gases by the of the PortablE Gas and Aerosol Sampling Units (PEGASUS) mobile station. The ground-based measurements have been completed by several coordinated overpasses of the ATR-42 and the F20 of SAFIRE. In this paper we present the first highlights of operations, which took place between June 6 and July 8 2013. Insights on the data provide with an unprecedented characterisation of the physico-chemical and properties aerosols and gas phase chemistry on air masses of various origins (pollution, marine, mineral dust, …..). The effect of aerosols on radiation fields is ascertained by coupling ground-based and aircraft measurements during dedicated overpasses providing with measurements of upwelling and downwelling shortwave and longwave radiation fluxes together with the properties of the aerosol load resolved on the column. Coordination with CALIPSO overpasses will also be explored.

  3. Composition of carbonaceous smoke particles from prescribed burning of a Canadian boreal forest: 1. Organic aerosol characterization by gas chromatography

    SciTech Connect

    Mazurek, M.A.; Laterza, C.; Newman, L.; Daum, P.; Cofer, W.R. III; Levine, J.S.; Winstead, E.L.

    1995-06-01

    In this study we examine the molecular organic constituents (C8 to C40 lipid compounds) collected as smoke particles from a Canadian boreal forest prescribed burn. Of special interest are (1) the molecular identity of polar organic aerosols, and (2) the amount of polar organic matter relative to the total mass of aerosol particulate carbon. Organic extracts of smoke aerosol particles show complex distributions of the lipid compounds when analyzed by capillary gas chromatography/mass spectrometry. The molecular constituents present as smoke aerosol are grouped into non-polar (hydrocarbons) and polar {minus}2 oxygen atoms) subtractions. The dominant chemical species found in the boreal forest smoke aerosol are unaltered resin compounds (C20 terpenes) which are abundant in unburned conifer wood, plus thermally altered wood lignins and other polar aromatic hydrocarbons. Our results show that smoke aerosols contain molecular tracers which are related to the biofuel consumed. These smoke tracers can be related structurally back to the consumed softwood and hardwood vegetation. In addition, combustion of boreal forest materials produces smoke aerosol particles that are both oxygen-rich and chemically complex, yielding a carbonaceous aerosol matrix that is enriched in polar substances. As a consequence, emissions of carbonaceous smoke particles from large-scale combustion of boreal forest land may have a disproportionate effect on regional atmospheric chemistry and on cloud microphysical processes.

  4. The effect of carrier gas contaminants on the charging probability of aerosols under bipolar charging conditions.

    PubMed

    Steiner, Gerhard; Reischl, Georg P

    2012-12-01

    This work concentrates on the experimental determination of the properties of ionic molecular clusters that are produced in the bipolar ionic atmosphere of a radioactivity based (241)Am charger. The main scope of this study was to investigate the dependency of the ions' properties on carrier gas contaminants caused by the evaporation of trace gases from different kinds of frequently encountered tubing materials. A recently developed high resolution mobility spectrometer allows the precise determination of the ions' electrical mobility; an empirical mass-mobility relationship was used to approximate the corresponding ion masses. It was found that impurities in the carrier gas dramatically change the pattern of the ion mobility/size distribution, resulting in very different ion properties that strongly depend on the carrier gas composition. Since the ion properties control the charging process of aerosols, it was further investigated how the different ion properties affect the calculation of the charging probabilities of aerosols. The results show that despite large variations of the ions' properties, only a minor effect on the calculated charging probabilities can be found.

  5. Gas- and aerosol-phase chemistry of nitrogen oxides (NOy) in a pine forest (BEACHON-RoMBAS 2011)

    NASA Astrophysics Data System (ADS)

    Fry, J.; Draper, D.; Zarzana, K. J.; Brown, S. S.; Dube, B.; Wagner, N.; Cohen, R. C.; Palm, B. B.; Ortega, A. M.; Campuzano Jost, P.; Day, D. A.; Jimenez, J. L.; Brune, W. H.; Karl, T.; Kaser, L.; Jud, W.; Hansel, A.

    2011-12-01

    Ambient measurements of NOy (NO2, peroxy- and alkyl-nitrates, and the gas/aerosol partitioning of the latter) and Potential Aerosol Mass measurements of NO3-initiated secondary organic aerosol formation in a 16 L flow-through reactor were made during the BEACHON-RoMBAS field campaign in U.S. Forest Service Manitou Forest Observatory, Colorado (July/August 2011). A cavity ringdown spectrometer (CRDS) is used to monitor NO3 and N2O5 , Thermal Desorption - Laser Induced Fluorescence (TD-LIF) is used to detect the NOy species as NO2; an Aerodyne Aerosol Mass Spectrometer (AMS) monitors chemical composition of aerosol; Proton Transfer Reaction Mass Spectrometry (PTR-TOF-MS) monitors the gas-phase organic compounds; and a thermal converter/chemiluminescent NO/NOx/NH3 analyzer monitors gas-phase inorganic nitrogen compounds. In the PAM measurements, a calibrated flow of NO3 is supplied to the reactor from a temperature-controlled N2O5 trap. With this suite of measurements we seek to elucidate the role of nitrate in biogenic SOA formation, as well as the fate of pollution emissions in a forest environment. We observe significant concentrations of ambient alkyl- and peroxynitrates, despite the remote forest location, and find evidence in PAM measurements that formation of these compounds is linked to organic aerosol production.

  6. Stratospheric aerosol and gas experiments I and II comparisons with ozonesondes

    SciTech Connect

    Veiga, R.E.; Cunnold, D.M.; Chu, W.P.

    1995-05-20

    Ozone profiles measured by the Stratospheric Aerosol and Gas Experiments (SAGE) I and II are compared with ozonesonde profiles at 24 stations over the period extending from 1979 through 1991. Ozonesonde/satellite differences at 21 stations with SAGE II overpasses were computed down to 11.5 km in the midlatitudes, to 15.5 km in the lower latitudes, and for nine stations with SAGE I overpasses down to 15.5 km. The set of individual satellite and ozonesonde profile comparisons most closely colocated in time and space shows mean absolute differences relative to the satellite measurement of 6 {plus_minus} 2% for SAGE II and 8 {plus_minus}3% for SAGE I. The ensemble of ozonesonde/satellite differences, when averaged over all altitudes, shows that for SAGE II, 70% were less than 5%, whereas for SAGE I, 50% were less than 5%. The best agreement occurred in the altitude region near the ozone density maximum where almost all the relative differences were less than 5%. Most of the statistically significant differences occurred below the ozone maximum down to the tropopause in the region of steepest ozone gradients and typically ranged between 0 and {minus}20%. Correlations between ozone and aerosol extinction in the northern midlatitudes indicate that aerosols had no discernible impact on the ozonesonde/satellite differences and on the stratosphere during 1984 to mid-1991. 42 refs., 8 figs., 1 tab.

  7. Overview of the Stratospheric Aerosol and Gas Experiment III (SAGE III) on the International Space Station

    NASA Astrophysics Data System (ADS)

    Flittner, David; Pitts, Michael; Zawodny, Joe; Hill, Charles; Damadeo, Robert; Moore, Randy; Cisewski, Michael

    2012-07-01

    The Stratospheric Aerosol and Gas Experiment (SAGE) III is the fourth generation of solar occultation instruments operated by NASA, the first coming under a different acronym, to investigate the Earth's upper atmosphere. Three flight-ready SAGE III instruments were built by Ball Aerospace in the late 1990s, with one launched aboard the former Russian Avaiation and Space Agency (now known as Roskosmos) Meteor-3M (M3M) platform on 10 December 2001 (continuing until the platform lost power in 2006). Another of the original instruments was manifested for the International Space Station (ISS) in the 2004 time frame, but was delayed because of budgetary considerations. Fortunately, that SAGE III/ISS mission was restarted in 2009 with a major focus upon filling an anticipated gap in ozone and aerosol observations in the second half of this decade. This exciting mission utilizes contributions from both the Science Mission Directorate and the Human Exploration and Operations Mission Directorate within the National Aeronautics and Space Administration and the European Space Agency to enable scientific measurements that will provide the basis for the analysis of five of the nine critical constituents identified in the U.S. National Plan for Stratospheric Monitoring. A related paper by Anderson et al. discusses the. Presented here is an overview of the mission architecture, its implementation and the data that will be produced by SAGE III/ISS, including their expected accuracy and coverage. The 52-degree inclined orbit of the ISS is well-suited for solar occultation and provides near-global observations on a monthly basis with excellent coverage of low and mid-latitudes. This is similar to that of the SAGE II mission (1985-2005), whose data set has served the international atmospheric science community as a standard for stratospheric ozone and aerosol measurements. The nominal science products include vertical profiles of trace gases, such as ozone, nitrogen dioxide and water

  8. Influence of crustal dust and sea spray supermicron particle concentrations and acidity on inorganic NO3- aerosol during the 2013 Southern Oxidant and Aerosol Study

    SciTech Connect

    Allen, Hannah M.; Draper, Danielle C.; Ayres, Benjamin R.; Ault, Andrew P.; Bondy, Amy L.; Takahama, S.; Modini, Robert; Baumann, K.; Edgerton, Eric S.; Knote, Christoph; Laskin, Alexander; Wang, Bingbing; Fry, Juliane L.

    2015-09-25

    The inorganic aerosol composition was measured in the southeastern United States, a region that exhibits high aerosol mass loading during the summer, as part of the 1 June to 15 July 2013 Southern Oxidant and Aerosol Study (SOAS) campaign. Measurements using a Monitor for AeRosols and GAses (MARGA), an ion chromatograph coupled with a wet rotating denuder and a steam-jet aerosol collector for monitoring of ambient inorganic gas and aerosol species, revealed two periods of high aerosol nitrate (NO3 ) concentrations during the campaign. These periods of high nitrate were correlated with increased concentrations of coarse mode mineral or sea spray aerosol species, particularly Na+ and Ca2+, and with a shift towards aerosol with larger (1 to 2.5 um) diameters. We suggest this nitrate aerosol forms by multiphase reactions of HNO3 and particles, reactions that are facilitated by transport of mineral dust and sea spray aerosol from a source within the United States. The observed high aerosol acidity prevents the formation of NH4NO3, the inorganic nitrogen species often dominant in fine-mode aerosol at higher pH. Calculation of the rate of the heterogeneous uptake of HNO3 on mineral aerosol supports the conclusion that aerosol NO3 is produced primarily by this process, and is likely limited by the availability of mineral dust surface area. Modeling of NO3 and HNO3 by thermodynamic equilibrium models (ISORROPIA II and E-AIM) reveals the importance of including mineral cations in the southeastern United States to accurately balance ion species and predict gas/aerosol phase partitioning.

  9. A Versatile, Automatic Chromatographic Column Packing Device

    ERIC Educational Resources Information Center

    Barry, Eugene F.; And Others

    1977-01-01

    Describes an inexpensive apparatus for packing liquid and gas chromatographic columns of high efficiency. Consists of stainless steel support struts, an Automat Getriebmotor, and an associated three-pulley system capable of 10, 30, and 300 rpm. (MLH)

  10. Gas-particle partitioning of primary organic aerosol emissions: (1) Gasoline vehicle exhaust

    NASA Astrophysics Data System (ADS)

    May, Andrew A.; Presto, Albert A.; Hennigan, Christopher J.; Nguyen, Ngoc T.; Gordon, Timothy D.; Robinson, Allen L.

    2013-10-01

    The gas-particle partitioning of the primary organic aerosol (POA) emissions from fifty-one light-duty gasoline vehicles (model years 1987-2012) was investigated at the California Air Resources Board Haagen-Smit Laboratory. Each vehicle was operated over the cold-start unified cycle on a chassis dynamometer and its emissions were sampled using a constant volume sampler. Four independent yet complementary approaches were used to investigate POA gas-particle partitioning: sampling artifact correction of quartz filter data, dilution from the constant volume sampler into a portable environmental chamber, heating in a thermodenuder, and thermal desorption/gas chromatography/mass spectrometry analysis of quartz filter samples. This combination of techniques allowed gas-particle partitioning measurements to be made across a wide range of atmospherically relevant conditions - temperatures of 25-100 °C and organic aerosol concentrations of <1-600 μg m-3. The gas-particle partitioning of the POA emissions varied continuously over this entire range of conditions and essentially none of the POA should be considered non-volatile. Furthermore, for most vehicles, the low levels of dilution used in the constant volume sampler created particle mass concentrations that were greater than a factor of 10 or higher than typical ambient levels. This resulted in large and systematic partitioning biases in the POA emission factors compared to more dilute atmospheric conditions, as the POA emission rates may be over-estimated by nearly a factor of four due to gas-particle partitioning at higher particle mass concentrations. A volatility distribution was derived to quantitatively describe the measured gas-particle partitioning data using absorptive partitioning theory. Although the POA emission factors varied by more than two orders of magnitude across the test fleet, the vehicle-to-vehicle differences in gas-particle partitioning were modest. Therefore, a single volatility distribution

  11. Gas Dynamics, Characterization, and Calibration of Fast Flow Flight Cascade Impactor Quartz Crystal Microbalances (QCM) for Aerosol Measurements

    NASA Technical Reports Server (NTRS)

    Grant, J.R.; Thorpe, A. N.; James, C.; Michael, A.; Ware, M.; Senftle, F.; Smith, S.

    1997-01-01

    During recent high altitude flights, we have tested the aerosol section of the fast flow flight cascade impactor quartz crystal microbalance (QCM) on loan to Howard University from NASA. The aerosol mass collected during these flights was disappointingly small. Increasing the flow through the QCM did not correct the problem. It was clear that the instrument was not being operated under proper conditions for aerosol collect ion primarily because the gas dynamics is not well understood. A laboratory study was therefore undertaken using two different fast flow QCM's in an attempt to establish the gas flow characteristics of the aerosol sections and its effect on particle collection, Some tests were made at low temperatures but most of the work reported here was carried out at room temperature. The QCM is a cascade type impactor originally designed by May (1945) and later modified by Anderson (1966) and Mercer et al (1970) for chemical gas analysis. The QCM has been used extensively for collecting and sizing stratospheric aerosol particles. In this paper all flow rates are given or corrected and referred to in terms of air at STP. All of the flow meters were kept at STP. Although there have been several calibration and evaluation studies of moderate flow cascade impactors of less than or equal to 1 L/rein., there is little experimental information on the gas flow characteristics for fast flow rates greater than 1 L/rein.

  12. Quantification of Biogenic and Anthropogenic Hydrocarbons using a Commercial Gas Chromatograph - Ion Trap Mass Spectrometer at a Ground Site near Fort McKay, AB

    NASA Astrophysics Data System (ADS)

    Tokarek, T. W.; Osthoff, H. D.

    2014-12-01

    The extraction of fossil fuels from the Alberta oil sands has been the focus of considerable attention due to its association with sizeable emissions of a variety of atmospheric pollutants, the magnitude and impacts of which are currently poorly constrained by observations. In order to more reliably estimate the magnitude and impact of these emissions, an intensive air quality measurement campaign, called "Fort McMurray Oil Sands Strategic Investigation of Local Sources" (FOSSILS), was conducted in the summer of 2013 as part of the Alberta-Canada joint oil sands monitoring program (JOSM) to identify and quantify emissions and their transformations from the Alberta oil sands. The challenge is that the region is surrounded by boreal forest, which provides a substantial background of biogenic hydrocarbons during summer. In this presentation, measurements of volatile organic compounds (VOCs) at the AMS13 ground site near Fort McKay, Alberta, from Aug 17 to Sept 6, 2013 using a commercial Griffin 450 gas chromatograph equipped with ion trap mass spectrometric detection and Tenax preconcentration are described. The combination of retention information and electron impact mass spectral data allowed unambiguous identification and quantification of the major biogenic monoterpenes, e.g., α and β-pinene, limonene, camphene, and 3Δ-carene, and of many anthropogenically derived hydrocarbons. Mixing ratios of biogenic hydrocarbons varied with time of day, temperature, and solar radiation, with maxima typically occurring at night, rationalized by nocturnal mixing heights and low mixing ratios of the nocturnal oxidants ozone (O3) and the nitrate radical (NO3). In contrast, mixing ratios of anthropogenic VOCs, e.g., benzene, toluene, ethyl benzene, and o-, p-, and m-xylene (BTEX), strongly depended on meteorological conditions, i.e., local wind direction. During episodes with high BTEX abundance, many additional high molecular weight hydrocarbons were observed which were not

  13. Gas-phase products and secondary aerosol yields from the ozonolysis of ten different terpenes

    NASA Astrophysics Data System (ADS)

    Lee, Anita; Goldstein, Allen H.; Keywood, Melita D.; Gao, Song; Varutbangkul, Varuntida; Bahreini, Roya; Ng, Nga L.; Flagan, Richard C.; Seinfeld, John H.

    2006-04-01

    The ozonolyses of six monoterpenes (α-pinene, β-pinene, 3-carene, terpinolene, α-terpinene, and myrcene), two sesquiterpenes (α-humulene and β-caryophyllene), and two oxygenated terpenes (methyl chavicol and linalool) were conducted individually in Teflon chambers to examine the gas-phase oxidation product and secondary organic aerosol (SOA) yields from these reactions. Particle size distribution and number concentration were monitored and allowed for the calculation of the SOA yield from each experiment, which ranged from 1 to 54%. A proton transfer reaction mass spectrometer (PTR-MS) was used to monitor the evolution of gas-phase products, identified by their mass to charge ratio (m/z). Several gas-phase oxidation products, formaldehyde, acetaldehyde, formic acid, acetone, acetic acid, and nopinone, were identified and calibrated. Aerosol yields, and the yields of these identified and calibrated oxidation products, as well as many higher m/z oxidation products observed with the PTR-MS, varied significantly between the different parent terpene compounds. The sum of measured oxidation products in the gas and particle phase ranged from 33 to 77% of the carbon in the reacted terpenes, suggesting there are still unmeasured products from these reactions. The observations of the higher molecular weight oxidation product ions provide evidence of previously unreported compounds and their temporal evolution in the smog chamber from multistep oxidation processes. Many of the observed ions, including m/z 111 and 113, have also been observed in ambient air above a Ponderosa pine forest canopy, and our results confirm they are consistent with products from terpene + O3 reactions. Many of these products are stable on the timescale of our experiments and can therefore be monitored in field campaigns as evidence for ozone oxidative chemistry.

  14. Secondary organic aerosol formation from the gas phase reaction of hydroxyl radicals with m-, o- and p-cresol

    NASA Astrophysics Data System (ADS)

    Henry, Françoise; Coeur-Tourneur, Cecile; Ledoux, Frédéric; Tomas, Alexandre; Menu, Dominique

    Secondary organic aerosol (SOA) formation during the atmospheric oxidation of cresols was investigated using a large smog chamber (8000 L), at atmospheric pressure, 294±2 K and low relative humidity (6-10%). Cresol oxidation was initiated by irradiation of cresol/CH 3ONO/NO/air mixtures. The cresol loss was measured by gas chromatography with a flame ionization detector (GC-FID) and the temporal evolution of the aerosol was monitored using a scanning mobility particle sizer (SMPS). The overall organic aerosol yield ( Y) was determined as the ratio of the suspended aerosol mass corrected for wall losses ( Mo) to the total reacted cresol concentrations assuming a particle density of 1.4 g cm -3. Analysis of the data clearly show that Y is a strong function of Mo and that SOA formation can be expressed by a one-product gas/particle partitioning absorption model. The aerosol formation is affected by the initial cresol concentration, which leads to aerosol yields from 9% to 42%. These results are in good agreement with a recent study performed on SOA formation from the photo-oxidation of o-cresol in a smog chamber. To our knowledge, the present work represents the first investigation of SOA formation from OH reaction with m- and p-cresol.

  15. Gas phase emissions from cooking processes and their secondary aerosol production potential

    NASA Astrophysics Data System (ADS)

    Klein, Felix; Platt, Stephen; Bruns, Emily; Termime-roussel, Brice; Detournay, Anais; Mohr, Claudia; Crippa, Monica; Slowik, Jay; Marchand, Nicolas; Baltensperger, Urs; Prevot, Andre; El Haddad, Imad

    2014-05-01

    -ToF-MS) were used to quantify OA and VOC emissions, respectively. SOA production potential of the different emissions was quantified by introducing them into the PSI mobile smog chamber and a potential aerosol chamber (PAM) where they were photochemically aged. The measurements of primary emissions suggest that the COA factor identified in ambient atmospheric aerosols is mostly related to fat release from frying with vegetable oils or grilling fatty-meats. In contrast, vegetable cooking (boiling and frying) was associated with significant VOC emissions. The VOC emissions from frying consist mainly of aldehydes which are formed through breaking of fatty acids. Gas phase composition, emission factors and SAPP from all these processes will be presented. This work was supported by the Swiss National Science Foundation as well as the Swiss Federal Office for the Environment. The research leading to these results has received funding from the European Community's Seventh Framework Programme (FP7/2007-2013) under grant agreement n.° 290605 (COFUND: PSI-FELLOW). J. Allan et al, Atmos. Chem. Phys. 10, 647-668 (2010) X.-F. Huang et al, Atmos. Chem. Phys. 10, 8933-8945 (2010) Y.-L. Sun et al, Atmos. Chem. Phys. 11, 1581-1602 (2011)

  16. High performance liquid chromatographic separations of gas oil samples and their hydrotreated products using commercial normal phases.

    PubMed

    Oro, Nicole E; Lucy, Charles A

    2011-10-28

    Three commercially available high performance liquid chromatography columns are used in normal phase or quasi-normal phase mode for the separation of gas oil samples. The columns are tested with 20 analytical standards to determine their suitability for separations of petroleum samples and their ability to separate the nitrogen group-types (pyrrole and pyridine) found in petroleum. The columns studied are polymeric hypercrosslinked polystyrene (HGN), a biphenyl phase, and a Chromegabond "DNAP" column from ES Industries. The HGN column separates gas oils based on both ring structure and heteroatom, while the biphenyl phase has low retention of most compounds studied in quasi-normal phase mode. The "DNAP" column is selective for nitrogen-containing compounds, separating them from PAHs as well as oxygen and sulphur compounds. Retention data of standards on all three columns is shown, along with chromatograms of gas oil samples on the HGN and "DNAP" columns.

  17. Kinetic limitations in gas-particle reactions arising from slow diffusion in secondary organic aerosol.

    PubMed

    Zhou, Shouming; Shiraiwa, Manabu; McWhinney, Robert D; Pöschl, Ulrich; Abbatt, Jonathan P D

    2013-01-01

    The potential for aerosol physical properties, such as phase, morphology and viscosity/ diffusivity, to affect particle reactivity remains highly uncertain. We report here a study of the effect of bulk diffusivity of polycyclic aromatic hydrocarbons (PAHs) in secondary organic aerosol (SOA) on the kinetics of the heterogeneous reaction of particle-borne benzo[a]pyrene (BaP) with ozone. The experiments were performed by coating BaP-ammonium sulfate particles with multilayers of SOA formed from ozonolysis of alpha-pinene, and by subsequently investigating the kinetics of BaP loss via reaction with excess ozone using an aerosol flow tube coupled to an Aerodyne Aerosol Mass Spectrometer (AMS). All reactions exhibit pseudo-first order kinetics and are empirically well described by a Langmuir-Hinshelwood (L-H) mechanism. The results show that under dry conditions (RH < 5%) diffusion through the SOA coating can lead to significant mass transfer constraints on the kinetics, with behavior between that previously observed by our group for solid and liquid organic coats. The reactivity of BaP was enhanced at -50% relative humidity (RH) suggesting that water uptake lowers the viscosity of the SOA, hence lifting the mass transfer constraint to some degree. The kinetics for -70% RH were similar to results obtained without SOA coats, indicating that the SOA had sufficiently low viscosity and was sufficiently liquid-like that reactants could rapidly diffuse through the coat. A kinetic multi-layer model for aerosol surface and bulk chemistry was applied to simulate the kinetics, yielding estimates for the diffusion coefficients (in cm2 s(-1)) for BaP in alpha-pinene SOA of 2 x 10(-14), 8 x 10(-14) and > 1 x 10(-12) for dry (RH < 5%), 50% RH and 70% RH conditions, respectively. These results clearly indicate that slow diffusion of reactants through SOA coats under specific conditions can provide shielding from gas-phase oxidants, enabling the long-range atmospheric transport of

  18. Kinetic limitations in gas-particle reactions arising from slow diffusion in secondary organic aerosol.

    PubMed

    Zhou, Shouming; Shiraiwa, Manabu; McWhinney, Robert D; Pöschl, Ulrich; Abbatt, Jonathan P D

    2013-01-01

    The potential for aerosol physical properties, such as phase, morphology and viscosity/ diffusivity, to affect particle reactivity remains highly uncertain. We report here a study of the effect of bulk diffusivity of polycyclic aromatic hydrocarbons (PAHs) in secondary organic aerosol (SOA) on the kinetics of the heterogeneous reaction of particle-borne benzo[a]pyrene (BaP) with ozone. The experiments were performed by coating BaP-ammonium sulfate particles with multilayers of SOA formed from ozonolysis of alpha-pinene, and by subsequently investigating the kinetics of BaP loss via reaction with excess ozone using an aerosol flow tube coupled to an Aerodyne Aerosol Mass Spectrometer (AMS). All reactions exhibit pseudo-first order kinetics and are empirically well described by a Langmuir-Hinshelwood (L-H) mechanism. The results show that under dry conditions (RH < 5%) diffusion through the SOA coating can lead to significant mass transfer constraints on the kinetics, with behavior between that previously observed by our group for solid and liquid organic coats. The reactivity of BaP was enhanced at -50% relative humidity (RH) suggesting that water uptake lowers the viscosity of the SOA, hence lifting the mass transfer constraint to some degree. The kinetics for -70% RH were similar to results obtained without SOA coats, indicating that the SOA had sufficiently low viscosity and was sufficiently liquid-like that reactants could rapidly diffuse through the coat. A kinetic multi-layer model for aerosol surface and bulk chemistry was applied to simulate the kinetics, yielding estimates for the diffusion coefficients (in cm2 s(-1)) for BaP in alpha-pinene SOA of 2 x 10(-14), 8 x 10(-14) and > 1 x 10(-12) for dry (RH < 5%), 50% RH and 70% RH conditions, respectively. These results clearly indicate that slow diffusion of reactants through SOA coats under specific conditions can provide shielding from gas-phase oxidants, enabling the long-range atmospheric transport of

  19. Aerosol and gas-phase characteristics in relation to meteorology: Case studies in populated arid settings

    NASA Astrophysics Data System (ADS)

    Crosbie, Ewan Colin

    Atmospheric aerosols and trace gases are a highly relevant component of the climate system affecting atmospheric radiative transfer and the hydrologic cycle. In arid and semi-arid regions, where cloud cover is often low and precipitation is generally scarce and sporadic, the driving processes accounting for the production, loss and transport of atmospheric constituents are often distinctly different from other climates. In arid regions, the same circulation dynamics that suppress cloud formation can be responsible for creating strong subsidence inversions, which cap atmospheric mixing and trap pollutants close to the surface, often placing populated arid regions high on global rankings of air pollution concerns. In addition, low soil moisture can encourage wind-blown dust emissions, which can be a significant fraction of the total aerosol loading in both coarse and fine modes on a mass basis. Three distinct focus regions are investigated over varying time scales, using a diverse set of techniques, and with wide-ranging primary goals. 1) the Tehran metropolitan area in Iran over a ten-year period from 2000-2009, 2) Tucson, Arizona over 2012-2014 with three intensive monitoring periods during summer 2014 and winter 2015 and 3) the San Joaquin Valley in California during the NASA DISCOVER-AQ campaign during Jan-Feb 2013. However, in all cases, local and regional scale meteorology play a significant role in controlling the spatiotemporal variability in trace gas and aerosol concentrations. Particular emphasis is placed on understanding transport pathways due to the local wind patterns and the importance of key meteorological parameters such as temperature, humidity and solar radiation on controlling production and loss mechanisms. While low in magnitude, the precipitation pattern is still an important sink mechanism that modulates gas phase and particle abundances in all three regions, either through scavenging or by promoting vertical mixing. The reported measurements

  20. Composition of Titan's lower atmosphere and simple surface volatiles as measured by the Cassini-Huygens probe gas chromatograph mass spectrometer experiment

    NASA Astrophysics Data System (ADS)

    Niemann, H. B.; Atreya, S. K.; Demick, J. E.; Gautier, D.; Haberman, J. A.; Harpold, D. N.; Kasprzak, W. T.; Lunine, J. I.; Owen, T. C.; Raulin, F.

    2010-12-01

    The Cassini-Huygens probe gas chromatograph mass spectrometer (GCMS) determined the composition of the Titan atmosphere from ˜140 km altitude to the surface. After landing, it returned composition data of gases evaporated from the surface. Height profiles of molecular nitrogen (N2), methane (CH4), and molecular hydrogen (H2) were determined. Traces were detected on the surface of evaporating methane, ethane (C2H6), acetylene (C2H2), cyanogen (C2N2), and carbon dioxide (CO2). The methane data showed evidence that methane precipitation occurred recently. The methane mole fraction was (1.48 ± 0.09) × 10-2 in the lower stratosphere (139.8-75.5 km) and (5.65 ± 0.18) × 10-2 near the surface (6.7 km to the surface). The molecular hydrogen mole fraction was (1.01 ± 0.16) × 10-3 in the atmosphere and (9.90 ± 0.17) × 10-4 on the surface. Isotope ratios were 167.7 ± 0.6 for 14N/15N in molecular nitrogen, 91.1 ± 1.4 for 12C/13C in methane, and (1.35 ± 0.30) × 10-4 for D/H in molecular hydrogen. The mole fractions of 36Ar and radiogenic 40Ar are (2.1 ± 0.8) × 10-7 and (3.39 ± 0.12) × 10-5, respectively. 22Ne has been tentatively identified at a mole fraction of (2.8 ± 2.1) × 10-7. Krypton and xenon were below the detection threshold of 1 × 10-8 mole fraction. Science data were not retrieved from the gas chromatograph subsystem as the abundance of the organic trace gases in the atmosphere and on the ground did not reach the detection threshold. Results previously published from the GCMS experiment are superseded by this publication.

  1. Evaluation of Comprehensive 2-D Gas Chromatography-Time-Of-Flight Mass Spectrometry for 209 Chlorinated Biphenyl Congeners in Two Chromatographic Runs

    EPA Science Inventory

    This research evaluates a recently developed comprehensive 2-D GC coupled with a time-of-flight (TOF) mass spectrometer for the potential separation of 209 PCB congeners, using a sequence of 1-D and 2-D chromatographic modes. In two consecutive chromatographic runs, using a 40 m,...

  2. Gas chromatographic vapor pressure determination of atmospherically relevant oxidation products of β-caryophyllene and α-pinene

    NASA Astrophysics Data System (ADS)

    Hartonen, Kari; Parshintsev, Jevgeni; Vilja, Vesa-Pekka; Tiala, Heidi; Knuuti, Sinivuokko; Lai, Ching Kwan; Riekkola, Marja-Liisa

    2013-12-01

    Vapor pressures (subcooled liquid, pliquid) of atmospherically relevant oxidation products of β-caryophyllene (β-caryophyllene aldehyde 0.18 ± 0.03 Pa and β-nocaryophyllene aldehyde 0.17 ± 0.03 Pa), and α-pinene (pinonaldehyde 16.8 ± 0.20 Pa, cis-pinic acid 0.12 ± 0.06 Pa, and cis-pinonic acid 0.99 ± 0.19 Pa) at 298 K were obtained by gas chromatography with flame ionization detection (FID) and mass spectrometric (MS) detection. The effects of stationary phase polarity and column film thickness on the vapor pressure values were investigated. Increase in stationary phase polarity provided smaller values, while increase in film thickness gave slightly higher values. Values for vapor pressure were at least two orders of magnitude lower when obtained by a method utilizing vaporization enthalpy (determined by gas chromatography-mass spectrometry) than by retention index method. Finally, the results were compared with values calculated by group contribution theory. For the β-caryophyllene oxidation products, the values measured by gas chromatography were slightly lower than those obtained by theoretical calculations. The opposite trend was observed for the α-pinene oxidation products. The methods based on gas chromatography are concluded to be highly useful for the determination of vapor pressures of semi-volatile compounds. Except for the most polar pinic and pinonic acids, differences between vapor pressure values obtained by GC-FID and GC-MS were small. Since GC-MS provides structural information simultaneously, the use of GC-MS is recommended.

  3. Initial operation and checkout of stratospheric aerosol gas experiment and Meteor-3M satellite

    NASA Astrophysics Data System (ADS)

    Habib, Shahid; Makridenko, Leonid; Chu, William P.; Salikhov, Rashid; Moore, Alvah S., Jr.; Trepte, Charles R.; Cisewski, Michael S.

    2003-04-01

    Under a joint agreement between the National Aeronautics and Space Agency (NASA) and the Russian Aviation and Space Agency (RASA), the Stratospheric Aerosol Gas Experiment III (SAGE III) instrument was launched in low earth orbit on December 10, 2001 aboard the Russian Meteor-3M(1) satellite from the Baikonur Cosmodrome. SAGE III is a spectrometer that measures attenuated radiation in the 282 nm to 1550 nm wavelength range to obtain the vertical profiles of ozone, aerosols, and other chemical species that are critical in studying the trends for the global climate change phenomena. This instrument version is more advanced than any of the previous versions and has more spectral bands, elaborate data gathering and storage, and intelligent terrestrial software. There are a number of Russian scientific instruments aboard the Meteor satellite in addition to the SAGE III instrument. These instruments deal with land imaging and biomass changes, hydro-meteorological monitoring, and helio-geophysical research. This mission was under development for over a period of six years and offered a number of unique technical and program management challenges for both Agencies. SAGE III has a long space heritage, and four earlier versions of this instrument have flown in space for nearly two decades now. In fact, SAGE II, the fourth instrument, is still flying in space on NASA's Earth Radiation Budget Satellite (ERBS), and has been providing important atmospheric data over the last 18 years. It has provided vital ozone and aerosol data in the mid latitudes and has contributed vastly in ozone depletion research. Ball Aerospace built the instrument under Langley Research Center's (LaRC) management. This paper presents the process and approach deployed by the SAGE III and the Meteor teams in performing the initial on-orbit checkout. It further documents a number of early science results obtained by deploying low risk, carefully coordinated procedures in resolving the serious operational

  4. Characterization of Secondary Organic Aerosol Precursors Using Two-Dimensional Gas-Chromatography

    NASA Astrophysics Data System (ADS)

    Roskamp, M.; Lou, W.; Pankow, J. F.; Harley, P. C.; Turnipseed, A.; Barsanti, K. C.

    2012-12-01

    The oxidation of volatile organic compounds (VOCs) plays a role in both regional and global air quality. However, field and laboratory research indicate that the body of knowledge around the identities, quantities and oxidation processes of these compounds in the ambient atmosphere is still incomplete (e.g., Goldstein & Galbally, 2007; Robinson et al., 2009). VOCs emitted to the atmosphere largely are of biogenic origin (Guenther et al., 2006), and many studies of ambient secondary organic aerosol (SOA) suggest that SOA is largely of biogenic origin (albeit closely connected to anthropogenic activities, e.g., de Gouw and Jimenez, 2009). Accurate modeling of SOA levels and properties will require a more complete understanding of biogenic VOCs (BOCs) and their atmospheric oxidation products. For example, satellite measurements indicate that biogenic VOC emissions are two to three times greater than levels currently included in models (Heald et al., 2010). Two-dimensional gas chromatography (GC×GC) is a powerful analytical technique that shows much promise in advancing the state-of-knowledge regarding BVOCs and their role in SOA formation. In this work, samples were collected during BEACHON-RoMBAS (Bio-hydro-atmosphere Interactions of Energy, Aerosols, Carbon, H2O, Organics & Nitrogen - Rocky Mountain Biogenic Aerosol Study) in July and August of 2011. The field site was a Ponderosa Pine forest near Woodland, CO, inside the Manitou Experimental Forest, which is operated by the US Forest Service. The area is characteristic of the central Rocky Mountains and trace gas monitoring indicates that little anthropogenic pollution is transported from the nearby urban areas (Kim et al. 2010 and references therein). Ambient and enclosure samples were collected on ATD (adsorption/thermal desorption) cartridges and analyzed for BVOCs using two-dimensional gas chromatography (GC×GC) with time of flight mass spectrometry (TOFMS) and flame ionized detection (FID). Measurements of

  5. Organic peroxides' gas-particle partitioning and rapid heterogeneous decomposition on secondary organic aerosol

    NASA Astrophysics Data System (ADS)

    Li, Huan; Chen, Zhongming; Huang, Liubin; Huang, Dao

    2016-02-01

    Organic peroxides, important species in the atmosphere, promote secondary organic aerosol (SOA) aging, affect HOx radicals cycling, and cause adverse health effects. However, the formation, gas-particle partitioning, and evolution of organic peroxides are complicated and still unclear. In this study, we investigated in the laboratory the production and gas-particle partitioning of peroxides from the ozonolysis of α-pinene, which is one of the major biogenic volatile organic compounds in the atmosphere and an important precursor for SOA at a global scale. We have determined the molar yields of hydrogen peroxide (H2O2), hydromethyl hydroperoxide (HMHP), peroxyformic acid (PFA), peroxyacetic acid (PAA), and total peroxides (TPOs, including unknown peroxides) and the fraction of peroxides in α-pinene/O3 SOA. Comparing the gas-phase peroxides with the particle-phase peroxides, we find that gas-particle partitioning coefficients of PFA and PAA are 104 times higher than the values from the theoretical prediction, indicating that organic peroxides play a more important role in SOA formation than previously expected. Here, the partitioning coefficients of TPO were determined to be as high as (2-3) × 10-4 m3 µg-1. Even so, more than 80 % of the peroxides formed in the reaction remain in the gas phase. Water changes the distribution of gaseous peroxides, while it does not affect the total amount of peroxides in either the gas or the particle phase. Approx. 18 % of gaseous peroxides undergo rapid heterogeneous decomposition on SOA particles in the presence of water vapor, resulting in the additional production of H2O2. This process can partially explain the unexpectedly high H2O2 yields under wet conditions. Transformation of organic peroxides to H2O2 also preserves OH in the atmosphere, helping to improve the understanding of OH cycling.

  6. Organic peroxides gas-particle partitioning and rapid heterogeneous decomposition on secondary organic aerosol

    NASA Astrophysics Data System (ADS)

    Li, H.; Chen, Z. M.; Huang, L. B.; Huang, D.

    2015-10-01

    Organic peroxides, important species in the atmosphere, will promote secondary organic aerosols (SOA) aging, affect HOx radicals cycling, and cause adverse health effects. However, the formation, gas-particle partitioning, and evolution of organic peroxides are extremely complicated and still unclear. In this study, we investigate in the laboratory the production and gas-particle partitioning of peroxides from the ozonolysis of α-pinene, which is one of the major biogenic volatile organic compounds in the atmosphere and is an important precursor for SOA at a global scale. We have determined the molar yields of hydrogen peroxide (H2O2), hydroxymethyl hydroperoxide (HMHP), peroxyformic acid (PFA), peroxyacetic acid (PAA) and total peroxides (TPO, including unknown peroxides) and the fraction of peroxides in SOA. Comparing the gas-phase and particle-phase peroxides, we find that gas-particle partitioning coefficients of PFA and PAA are 104 times higher than theoretical prediction, indicating that organic peroxides play a more important role in the SOA formation than expected previously. Here, we give the partitioning coefficients of TPO as (2-3) × 10-4 m3μg-1. Even so, more than 80 % of the peroxides formed in the reaction remain in the gas phase. Water does not affect the total amount of peroxides in either the gas or particle phase, but can change the distribution of gaseous peroxides. About 18 % gaseous peroxides undergo rapid heterogeneous decomposition on SOA particles in the presence of water vapor, resulting in the additional production of H2O2. This process can partially interpret the unexpected high H2O2 yield under wet conditions. Transformation of organic peroxides to H2O2 also saves OH in the atmosphere, helping to improve the understanding of OH cycling.

  7. Algorithms and sensitivity analyses for stratospheric aerosol and gas experiment II water vapor retrieval

    SciTech Connect

    Chu, W.P.; Thomason, L.W.; Buglia, J.J.; McCormick, M.P.; McMaster, L.M. ); Chiou, E.W.; Larsen, J.C. ); Rind, D. ); Oltmans, S. )

    1993-03-20

    This paper provides a detailed description of the current operational inversion algorithm for the retrieval of water vapor vertical profiles from the Stratospheric Aerosol and Gas Experiment II (SAGE II) occultation data at the 0.94-[mu]m wavelength channel. This algorithm is different from the algorithm used for the retrieval of the other species such as aerosol, ozone, and nitrogen dioxide because of the nonlinear relationship between the concentration versus the broad band absorption characteristics of water vapor. Included in the discussion of the retrieval algorithm are problems related to the accuracy of the computational scheme, accuracy of the removal of other interfering species, and the expected uncertainty of the retrieved profile. A comparative analysis on the computational schemes used for the calculation of the water vapor transmission at the 0.94-[mu]m wavelength region is presented. Analyses are also presented on the sensitivity of the retrievals to interferences from the other species which contribute to the total signature as observed at the 0.94-[mu]m wavelength channel on SAGE II instrument. Error analyses of the SAGE II water vapor retrieval is shown, indicating that good quality water vapor data are being produced by the SAGE II measurements. 27 refs., 10 figs., 1 tab.

  8. Examination of the kinetic isotopic effect to the acetylation derivatization for the gas chromatographic-combustion-isotope ratio mass spectrometric doping control analysis of endogenous steroids.

    PubMed

    Angelis, Yiannis S; Kioussi, Maroula K; Kiousi, Polyxeni; Brenna, J Thomas; Georgakopoulos, Costas G

    2012-12-01

    In gas chromatographic-combustion-isotope ratio mass spectrometry (GC-C-IRMS) doping control analysis, endogenous androgenic anabolic steroids and their metabolites are commonly acetylated using acetic anhydride reagent, thus incorporating exogenous carbon that contributes to the measured isotope ratio. Comparison of the endogenous δ(13)C of free, mono-, and di-acetylated steroids requires application of corrections, typically through straightforward use of the mass balance equation. Variability in kinetic isotope effects (KIE) due to steroid structures could cause fractionation of endogenous steroid carbon, resulting in inaccurate results. To test for possible KIE influence on δ(13)C, acetic anhydride of graded isotope ratio within the natural abundance range was used under normal derivatization conditions to test for linearity. In all cases, plots of measured steroid acetate δ(13)C versus acetic anhydride δ(13)C were linear and slopes were not significantly different. Regression analysis of the Δδ(13)C of enriched acetic anhydrides versus Δδ(13)C of derivatized steroids shows that KIE are similar in all cases. We conclude that δ(13)C calculated from the mass balance equation is independent of the δ(13)C of the acetic anhydride reagent, and that net KIE under normal derivatization conditions do not bias the final reported steroid δ(13)C.

  9. Determination of plant stanols and plant sterols in phytosterol enriched foods with a gas chromatographic-flame ionization detection method: NMKL collaborative study.

    PubMed

    Laakso, Päivi H

    2014-01-01

    This collaborative study with nine participating laboratories was conducted to determine the total plant sterol and/or plant stanol contents in phytosterol fortified foods with a gas chromatographic method. Four practice and 12 test samples representing mainly commercially available foodstuffs were analyzed as known replicates. Twelve samples were enriched with phytosterols, whereas four samples contained only natural contents of phytosterols. The analytical procedure consisted of two alternative approaches: hot saponification method, and acid hydrolysis treatment prior to hot saponification. As a result, sterol/stanol compositions and contents in the samples were measured. The amounts of total plant sterols and total plant stanols varying from 0.005 to 8.04 g/100 g product were statistically evaluated after outliers were eliminated. The repeatability RSD (RSDr) varied from 1.34 to 17.13%. The reproducibility RSD (RSDR) ranged from 3.03 to 17.70%, with HorRat values ranging from 0.8 to 2.1. When only phytosterol enriched food test samples are considered, the RSDr ranged from 1.48 to 6.13%, the RSD, ranged from 3.03 to 7.74%, and HorRat values ranged from 0.8 to 2.1. Based on the results of this collaborative study, the study coordinator concludes the method is fit for its purpose.

  10. Gas chromatographic method for the determination of residual monomers, 2-(acryloyloxy)ethyl isocyanate and 2-(methacryloyloxy)ethyl isocyanate, as curing agents in an ultraviolet curable adhesive.

    PubMed

    Kim, Byoung-Hyoun; Kim, Nosun; Moon, Dong Cheul

    2014-02-01

    A gas chromatographic method is described for the determination of residual 2-(acryloyloxy)ethyl isocyanate (AOI) and 2-(methacryloyloxy)ethyl isocyanate (MOI) as curing agents in an ultraviolet curable adhesive. Pre-column derivatization was employed in the determination of AOI and MOI as a means of enhancing the response of the flame ionization detector. Urethane derivatives of AOI and MOI were derived using methanol for 30 min at room temperature. The accuracies (n = 5, three concentration levels) were in the range of 113.4 to 126.7%, and precisions (n = 5, three concentration levels) were in the range of 0.8 to 4.3% for AOI-OMe. Furthermore, the accuracies were in the range of 79.5 to 108.6% and the precisions were in the range of 1.0 to 2.4% for MOI-OMe. The correlation coefficients of six calibration standards were all greater than 0.9999 for AOI-OMe and greater than 0.9998 for MOI-OMe over the range from 10 to 100 µg/mL.

  11. Gas chromatographic determination of polycyclic aromatic hydrocarbons in water and smoked rice samples after solid-phase microextraction using multiwalled carbon nanotube loaded hollow fiber.

    PubMed

    Matin, Amir Abbas; Biparva, Pourya; Gheshlaghi, Mohammad

    2014-12-29

    A novel solid-phase microextraction fiber was prepared based on multiwalled carbon nanotubes (MWCNTs) loaded on hollow fiber membrane pores. Stainless steel wire was used as unbreakable support. The major advantages of the proposed fiber are its (a) high reproducibility due to the uniform structure of the hollow fiber membranes, (b) high extraction capacity related to the porous structure of the hollow fiber and outstanding adsorptive characteristics of MWCNTs. The proposed fiber was applied for the microextraction of five representative polycyclic aromatic hydrocarbons (PAHs) from aqueous media (river and hubble-bubble water) and smoked rice samples followed by gas chromatographic determination. Analytical merits of the method, including high correlation coefficients [(0.9963-0.9992) and (0.9982-0.9999)] and low detection limits [(9.0-13.0ngL(-1)) and (40.0-150.0ngkg(-1))] for water and rice samples, respectively, made the proposed method suitable for the ultra-trace determination of PAHs. PMID:25476686

  12. Selective Retention of Explosives and Related Compounds on Gas-Chromatographic Capillary Columns Coated with Lanthanide(III) ß-diketonate Polymers

    SciTech Connect

    Harvey, Scott D.; Wenzel, Thomas J.

    2009-09-04

    The purpose of this research was to investigate coating capillary columns with lanthanide(III) beta-diketonate polymers to provide gas-chromatographic columns with selectivity toward explosives and related compounds. Capillary columns were statically coated with a combination of a lanthanide(III) beta-diketonate polymer, which utilized p-di(4,4,5,5,6,6,6-heptafluoro-1,3-hexanedionyl)benzene (dihed) as a ligand, and SE-30. A novel coating technique was developed that used a methanol-containing azeotrope to provide solubility for both polymers while maintaining a low boiling point compatible with static coating. As based on temperature-programmed retention indices, the custom experimental columns displayed selective retention of nitroaromatic, nitroalkane, and nitrate ester test probes relative to an appropriate SE-30 control column. Selective retention was more pronounced for strong Lewis base analytes (i.e., cyclohexanone). Relative analyte retention on the La(dihed), Tb(dihed) and Eu(dihed) columns are discussed relative to Lewis acidity and solubility of the polymer in the azeotrope coating solution.

  13. Gas chromatographic mass spectrometric detection of dihydroxy fatty acids preserved in the 'bound' phase of organic residues of archaeological pottery vessels.

    PubMed

    Hansel, Fabricio A; Bull, Ian D; Evershed, Richard P

    2011-07-15

    A methodology is presented for the determination of dihydroxy fatty acids preserved in the 'bound' phase of organic residues preserved in archaeological potsherds. The method comprises saponification, esterification, silica gel column chromatographic fractionation, and analysis by gas chromatography/mass spectrometry. The electron ionisation mass spectra of the trimethylsilyl ether methyl ester derivatives are characterised by fragment ions arising from cleavage of the bond between the two vicinal trimethylsiloxy groups. Other significant fragment ions are [M-15](+.), [M-31](+.), m/z 147 and ions characteristic of vicinal disubstituted (trimethylsiloxy) TMSO- groups (Δ(7,8), Δ(9,10), Δ(11,12) and Δ(13,14): m/z 304, 332, 360 and 388, respectively). The dihydroxy fatty acids identified in archaeological extracts exhibited carbon numbers ranging from C(16) to C(22) and concentrations varying from 0.05 to 14.05 µg g(-1) . The wide range of dihydroxy fatty acids observed indicates that this approach may be applied confidently in screening archaeological potsherds for the degradation products of monounsaturated fatty acids derived from commodities processed in archaeological pottery vessels.

  14. 2,3-di-O-methoxymethyl-6-O-tert-butyldimethylsilyl-beta-cyclodextrin, a useful stationary phase for gas chromatographic separation of enantiomers.

    PubMed

    Takahisa, Eisuke; Engel, Karl-Heinz

    2005-05-27

    Heptakis(2,3-di-O-methoxymethyl-6-O-tert-butyldimethylsilyl)-beta-cyclodextrin (2,3-MOM-6-TBDMS-beta-CD), synthesized by using methoxymethylchloride (MOM-Cl) as derivatization reagent, was used for capillary gas chromatographic separation of enantiomers. The new chiral stationary phase proved to be suitable for the enantiodifferentiation of volatiles from various chemical classes. Compared to the corresponding gamma-CD derivative (2,3-MOM-6-TBDMS-gamma-CD), the spectrum of compounds for which enantiomers could be separated was more limited and the enantioseparation achieved was generally less pronounced. Unusually high separation factors were observed for 2-alkyl esters of short chain acids (C2-C6). Phenomena underlying the enantioseparation of 2-pentyl acetate (alpha: 4.31; 35 degrees C) were investigated by determining thermodynamic parameters. Data show that only one enantiomer is retained significantly on the chiral stationary phase whereas the other one behaves like the hydrocarbons used as references. PMID:15974081

  15. Limits of detections for the determination of mono- and dicarboxylic acids using gas and liquid chromatographic methods coupled with mass spectrometry

    PubMed Central

    Št’ávová, Jana; Beránek, Josef; Nelson, Eric P.; Diep, Bonnie A.; Kubátová, Alena

    2011-01-01

    The chromatographic separation and instrumental limits of detection (LODs) were obtained for a broad range of C1-C18 monocarboxylic (MCAs) and C2-C14 dicarboxylic acids (DCAs) employing either chemical derivatization followed by gas chromatography-mass spectrometry and flame ionization detection (GC-MS/FID) or direct analysis with liquid chromatography high resolution MS and tandem MS (LC-MS). Suitability, efficiency and stability of reaction products for several derivatization agents used for esterification (BF3/butanol), and trimethysilylation, including trimethylsilyl-N-N-dimethylcarbamate (TMSDMC) and N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) were evaluated. The lowest limits of detection for the majority of compounds below 10 pg (with the exception of acetic acid) were obtained for derivatization with BF3/butanol followed by GC-MS in the total ion current (TIC) mode. Further improvements were achieved when applying either selected ion monitoring (SIM), which decreased the LODs to 1–4 pg or a combination of SIM and TIC (SITI) (2–5 pg). GC-FID provided LODs comparable to those obtained by GC-MS TIC. Both trimethylsilylation (followed by GC-MS) and direct LC-MS/MS analysis yielded LODs of 5– 40 pg for most of the acids. For volatile acids the LODs were higher, e.g., 25 and 590 ng for TMSDMC and BSTFA derivatized formic acid, respectively whereas the LC-MS methods did not allow for the analysis of formic acid at all. PMID:21185238

  16. Comparison of multiple linear regression, partial least squares and artificial neural networks for prediction of gas chromatographic relative retention times of trimethylsilylated anabolic androgenic steroids.

    PubMed

    Fragkaki, A G; Farmaki, E; Thomaidis, N; Tsantili-Kakoulidou, A; Angelis, Y S; Koupparis, M; Georgakopoulos, C

    2012-09-21

    The comparison among different modelling techniques, such as multiple linear regression, partial least squares and artificial neural networks, has been performed in order to construct and evaluate models for prediction of gas chromatographic relative retention times of trimethylsilylated anabolic androgenic steroids. The performance of the quantitative structure-retention relationship study, using the multiple linear regression and partial least squares techniques, has been previously conducted. In the present study, artificial neural networks models were constructed and used for the prediction of relative retention times of anabolic androgenic steroids, while their efficiency is compared with that of the models derived from the multiple linear regression and partial least squares techniques. For overall ranking of the models, a novel procedure [Trends Anal. Chem. 29 (2010) 101-109] based on sum of ranking differences was applied, which permits the best model to be selected. The suggested models are considered useful for the estimation of relative retention times of designer steroids for which no analytical data are available.

  17. Gas chromatographic analysis of guanidino compounds in sera and urine of uremic patients using glyoxal and ethyl chloroformate as derivatizing reagents.

    PubMed

    Majidano, Subhan Ali; Khuhawar, Muhammad Yar

    2013-01-01

    Gas chromatographic (GC) method has been developed for the determination of the guanidino compounds: guanidine (G), methylguanidine (MG), guanidinoacetic acid (GAA), guanidinopropionic acid (GPA), guanidinobutyric acid (GBA) and guanidinosuccinic acid (GSA) was carried out after precolumn derivatization with glyoxal and ethyl chloroformate from the column HP-5 (30 m × 0.32 mm i.d.) at 90°C for 3 min, followed by a heating rate 25°C/min up to 260°C with a nitrogen flow rate of 2 ml/min. Detection was by FID. The linear calibrations were obtained within 0.1-20.0 μmol/L, with limits of detection (LODs) within 0.014-0.024 μmol/L. The separation and derivatization was repeatable (n = 6) with relative standard deviations (RSD) within 0.8-1.9% in retention time and 0.5-1.8% in peak height/peak area. A number of additives and amino acids did not affect the determination. The method was applied for the determination of guanidino compounds from the serum and urine of 9 healthy volunteers and 8 uremic patients and the amounts found were in the range 0.08-0.48 and below the limit of detection (LOD) - 345 μmol/L and 1.82 - 13.88 and 0.77 - 432.0 μmol/L with RSDs within 4.2%, respectively. PMID:23400288

  18. Determination of diethylhexyladipate and acetyltributylcitrate in aqueous extracts after cloud point extraction coupled with microwave assisted back extraction and gas chromatographic separation.

    PubMed

    Zygoura, Panagiota D; Paleologos, Evangelos K; Riganakos, Kyriakos A; Kontominas, Michael G

    2005-11-01

    The determination of commercial plasticizers (di-(2-ethylhexyl)adipate (DEHA) and acetyl tributyl citrate (ATBC)) in aqueous solutions is described. The newly proposed technique of applying microwaves to cloud point extracts in order to enable combination with gas chromatographic analysis has been used for this purpose. Both plasticizers were entrapped in the micelles of the non-ionic surfactant Triton X-114 and removed from the bulk phase by centrifugation. Micellization was enhanced by increasing the ionic strength of the solution with concentrated NaCl. Extraction recoveries of the proposed method were over 95% for water and 3% (w/v) aqueous acetic acid and over 85% for 10% (v/v) aqueous ethanol, respectively. The calibration curves obtained, following the proposed methodology have a linear range between 50 and 2000 microg/L for each analyte while the detection limits were as low as 15 and 19 microg/L for DEHA and ATBC, respectively, with an RSD below 5% even for low concentrations. As an analytical demonstration the proposed methodology was applied for the determination of the migration levels of the selected plasticizers from a PVC food packaging film into aqueous simulants.

  19. Development of a Low Power Gas Chromatograph-Mass Spectrometer for In-Situ Detection of Organics in Martian Soil

    NASA Technical Reports Server (NTRS)

    Pinnick, Veronica; Buch, Arnaud; VanAmerom, Friso H. W.; Danell, Ryan M.; Brinckerhoff, William; Mahaffy, Paul; Cotter, Robert J.

    2011-01-01

    The Mars Organic Molecule Analyzer (MOMA) is a joint venture by NASA and the European Space Agency (ESA) to develop a sensitive, light-weight, low-power mass spectrometer for chemical analysis on Mars. MOMA is a key analytical instrument aboard the 2018 ExoMars rover mission seeking signs of past or present life. The current prototype was built to demonstrate operation of gas chromatography (OC) and laser desorption (LD) mass spectrometry under martian ambient conditions (5-7 Torr of CO2-rich atmosphere). Recent reports have discussed the MO MA concept, design and performance. Here, we update the current prototype performance, focusing specifically on the GCMS mode.

  20. Acidic methanolysis v. alkaline saponification in gas chromatographic characterization of mycobacteria: differentiation between Mycobacterium avium-intracellulare and Mycobacterium gastri.

    PubMed

    Larsson, L

    1983-08-01

    Mycobacterium avium-intracellulare and M.gastri were analyzed with capillary gas chromatography after each strain had been subjected to acidic methanolysis or to alkaline saponification followed by methylation. Prominent peaks of myristic, palmitoleic, palmitic, oleic, stearic and tuberculostearic acids were found in the chromatograms of both species, whereas 2-octadecanol and 2-eicosanol were detected only in M. avium-intracellulare. In initial runs, both of the derivatization principles yielded virtually identical chromatograms for a given strain. After repeated injections of extracts from alkaline saponification, however, the alcohol peaks showed pronounced tailing and finally almost disappeared from the chromatograms. This disadvantage, which was not observed when only acid methanolysis was used, could be overcome with trifluoroacetylation. Restored peak shape of the underivatized alcohols could be achieved by washing the cross-linked stationary phase in the capillary tubing with organic solvents. The study demonstrated the importance of conditions which enable separation of 2-octadecanol and 2-eicosanol when gas chromatography is used for species identification of mycobacteria.

  1. Gas chromatographic determination of some phenolic compounds in fuels and engine oil after simultaneous derivatization and microextraction.

    PubMed

    Farajzadeh, Mir Ali; Yadeghari, Adeleh; Khoshmaram, Leila; Ghorbanpour, Houshang

    2014-10-01

    In this study, a simultaneous derivatization/air-assisted liquid-liquid microextraction method has been developed for sample preparation of some phenolic compounds in fuels and engine oil. Analytes are transferred by back liquid-liquid extraction into NaOH solution and then are derivatized with butyl chloroformate and extracted simultaneously into carbon tetrachloride. The extracted derivatized analytes are analyzed using gas chromatography with flame ionization detection. The effect of extracting solvent type, derivatization agent and extraction solvent volumes, ionic strength of the aqueous solution, number of extraction cycles, etc., on the extraction efficiency is investigated. The calibration graphs are linear in the range of 3-10,000 μg/L. Enhancement factors, enrichment factors, and extraction recoveries are in the ranges of 497 to 1471, 571 to 991, and 60 to 109%, respectively. Detection limits are obtained in the range of 0.8 to 2.0 μg/L. Relative standard deviations for the extraction of each selected phenols are in the ranges of 2-4% for intraday (n = 6) and 3-6% (n = 5) for interday precisions for 200 μg/L. This technique is successfully applied for the extraction, preconcentration, and determination of the selected phenols in gasoline, kerosene, gas oil, and engine oil. PMID:25082460

  2. Gas chromatographic determination of some phenolic compounds in fuels and engine oil after simultaneous derivatization and microextraction.

    PubMed

    Farajzadeh, Mir Ali; Yadeghari, Adeleh; Khoshmaram, Leila; Ghorbanpour, Houshang

    2014-10-01

    In this study, a simultaneous derivatization/air-assisted liquid-liquid microextraction method has been developed for sample preparation of some phenolic compounds in fuels and engine oil. Analytes are transferred by back liquid-liquid extraction into NaOH solution and then are derivatized with butyl chloroformate and extracted simultaneously into carbon tetrachloride. The extracted derivatized analytes are analyzed using gas chromatography with flame ionization detection. The effect of extracting solvent type, derivatization agent and extraction solvent volumes, ionic strength of the aqueous solution, number of extraction cycles, etc., on the extraction efficiency is investigated. The calibration graphs are linear in the range of 3-10,000 μg/L. Enhancement factors, enrichment factors, and extraction recoveries are in the ranges of 497 to 1471, 571 to 991, and 60 to 109%, respectively. Detection limits are obtained in the range of 0.8 to 2.0 μg/L. Relative standard deviations for the extraction of each selected phenols are in the ranges of 2-4% for intraday (n = 6) and 3-6% (n = 5) for interday precisions for 200 μg/L. This technique is successfully applied for the extraction, preconcentration, and determination of the selected phenols in gasoline, kerosene, gas oil, and engine oil.

  3. Chromatographic fingerprint analysis of metabolites in natural and artificial agarwood using gas chromatography-mass spectrometry combined with chemometric methods.

    PubMed

    Gao, Xiaoxia; Xie, Mingrong; Liu, Shaofeng; Guo, Xiaoling; Chen, Xiaoying; Zhong, Zhaojian; Wang, Lei; Zhang, Weimin

    2014-09-15

    Agarwood is a resinous material formed in wounded Aquilaria sinensis in China, which is widely used as an effective traditional Chinese medicine (TCM). This study is aimed to use gas chromatography-mass spectrometry combined with chemometric methods to create reliable criteria for accurate identification of natural agarwood and artificial agarwood, as well as for quality evaluation of artificial agarwood. Natural agarwood and artificial agarwood (stimulated by formic acid or formic acid plus fungal inoculation) were used as standards and controls for the gas chromatography-mass spectrometry (GC-MS) and multivariate analysis. The identification criteria developed were applied to commercial agarwood. A reliable criteria including correlation coefficient of GC-MS fingerprint of natural agarwood and 22 markers of metabolism in natural and artificial agarwood was constructed. Compared with chemically stimulated agarwood (formic acid) and in terms of the 22 markers, artificial agarwood obtained by formic acid stimulation and fungal inoculation were much closer to natural agarwood. The study demonstrates that the chemical components of artificial agarwood obtained by comprehensive stimulated method (formic acid plus fungal inoculation) are much closer to the natural agarwood than those obtained by chemically stimulated method (formic acid), as times goes by. A reliable criteria containing correlation coefficient of GC-MS fingerprint of natural agarwood and 22 metabolism markers can be used to evaluate the quality of the agarwood. As an application case, three samples were identified as natural agarwood from the 25 commercial agarwood by using the evaluation method.

  4. Determination of volatile organic and polycyclic aromatic hydrocarbons in crude oil with efficient gas-chromatographic methods.

    PubMed

    Wang, Haijing; Geppert, Helmut; Fischer, Thomas; Wieprecht, Wolfgang; Möller, Detlev

    2015-01-01

    Determination of volatile organic compounds (VOCs) in crude oil, such as super volatile organic compounds (super VOCs) and simple polycyclic aromatic hydrocarbons (PAHs), is vital for targeting crude oil spill spots. In this study, a static headspace gas chromatography flame ionization detection method was established for determination of super VOCs in crude oil with both external and internal standard determination, which can be used in the field when using portable gas chromatography. Identification was done by comparing the retention time with the corresponding standards and quantitation was done with a new one-drop method. Another simplified and efficient method was performed to analyze volatile PAHs in crude oil, which can also be used in field analysis. Toluene was used as the extraction solvent for PAHs in crude oil. Method validation for both analyses was satisfactory. The result showed that n-butane and n-pentane were maximum super VOCs and naphthalene, phenanthrene and fluorene were the main PAHs in the crude oil studied. The super VOCs quantity ranged from 3 to 6% and the main PAHs consisted of 0.02-0.06% of studied crude oil. PMID:25225200

  5. MODELING AEROSOL FORMATION FROM ALPHA-PINENE + NOX IN THE PRESENCE OF NATURAL SUNLIGHT USING GAS PHASE KINETICS AND GAS-PARTICLE PARTITIONING THEORY. (R826771)

    EPA Science Inventory

    A kinetic mechanism was used to link and model the gas-phase reactions and
    aerosol accumulation resulting from src="/ncer/pubs/images/alpha.gif">-pinene reactions in the presence of sunlight,
    ozone (O3), and oxides of nitrogen
    (NO

  6. Comparison of Stratospheric Aerosol and Gas Experiment II and balloon-borne stratospheric water vapor measurements

    NASA Technical Reports Server (NTRS)

    Pruvost, P.; Ovarlez, J.; Lenoble, J.; Chu, W. P.

    1993-01-01

    The Stratospheric Aerosol and Gas Experiment II has one channel at 940 nm related to water vapor. Two inversion procedures were developed independently in order to obtain the water vapor profile: the Chahine method by the Langley Research Center, and the Mill method by the Laboratoire d'Optique Atmospherique. Comparisons were made between these two algorithms and some results are presented at midlatitudes (about 45 deg N) and tropical latitudes (12-25 deg S). They are compared with in situ frost point hygrometer data provided by balloon experiments from the Laboratoire de Meteorologie Dynamique. At +/- 0.5 ppmv, agreement between the inversion results and the experimental results was obtained in the altitude range from 18-19 to 26-27 km. Below 18-19 km and above 26-27 km the error is larger (sometimes 1 ppmv and more).

  7. Simultaneous determination of CFC-11, CFC-12 and CFC-113 in seawater samples using a purge and trap gas-chromatographic system.

    PubMed

    Massolo, Serena; Rivaro, Paola; Frache, Roberto

    2009-12-15

    We have optimized the analytical parameters of a homemade instrument for the simultaneous measurement of the chlorofluorocarbons CCl(2)F(2) (CFC-12), CCl(3)F (CFC-11) and C(2)Cl(3)F(3) (CFC-113) in seawater. Seawater samples are flame sealed into 60 ml glass ampoules avoiding any contact with the atmosphere and stored in cold, dark condition until analysis. In the laboratory, after cracking the ampoule in an enclosed chamber filled with ultra-pure nitrogen, the seawater sample is transferred to a stripping chamber, where ultra-pure nitrogen is used to purge the dissolved CFCs from the seawater. The extracted gases are then cryogenically trapped, subsequently the trap is isolated and heated and the CFCs are transferred by a carrier gas stream into a precolumn and then are separated on a gaschromatographic packed column. To separate adequately CFC-12 from N(2)O, during the early part of the chromatographic run, the gas stream passes through a molecular sieve, which is then isolated and backflushed. The CFCs are detected on an electron capture detector ((63)Ni ECD). After a careful choice of the experimental conditions, the performances of the system were evaluated. The detection limits for seawater samples are: 0.0081 pmol kg(-1) for CFC-12, 0.0073 pmol kg(-1) for CFC-11 and 0.0043 pmol kg(-1) for CFC-113. The reproducibility of replicate samples lies within 5% for the three CFCs. The system has been successfully employed for CFC measurements in seawater samples collected in the Ross Sea (Antarctica) in the framework of the Italian Antarctic research project. PMID:19836579

  8. Fuel composition and secondary organic aerosol formation: gas-turbine exhaust and alternative aviation fuels.

    PubMed

    Miracolo, Marissa A; Drozd, Greg T; Jathar, Shantanu H; Presto, Albert A; Lipsky, Eric M; Corporan, Edwin; Robinson, Allen L

    2012-08-01

    A series of smog chamber experiments were performed to investigate the effects of fuel composition on secondary particulate matter (PM) formation from dilute exhaust from a T63 gas-turbine engine. Tests were performed at idle and cruise loads with the engine fueled on conventional military jet fuel (JP-8), Fischer-Tropsch synthetic jet fuel (FT), and a 50/50 blend of the two fuels. Emissions were sampled into a portable smog chamber and exposed to sunlight or artificial UV light to initiate photo-oxidation. Similar to previous studies, neat FT fuel and a 50/50 FT/JP-8 blend reduced the primary particulate matter emissions compared to neat JP-8. After only one hour of photo-oxidation at typical atmospheric OH levels, the secondary PM production in dilute exhaust exceeded primary PM emissions, except when operating the engine at high load on FT fuel. Therefore, accounting for secondary PM production should be considered when assessing the contribution of gas-turbine engine emissions to ambient PM levels. FT fuel substantially reduced secondary PM formation in dilute exhaust compared to neat JP-8 at both idle and cruise loads. At idle load, the secondary PM formation was reduced by a factor of 20 with the use of neat FT fuel, and a factor of 2 with the use of the blend fuel. At cruise load, the use of FT fuel resulted in no measured formation of secondary PM. In every experiment, the secondary PM was dominated by organics with minor contributions from sulfate when the engine was operated on JP-8 fuel. At both loads, FT fuel produces less secondary organic aerosol than JP-8 because of differences in the composition of the fuels and the resultant emissions. This work indicates that fuel reformulation may be a viable strategy to reduce the contribution of emissions from combustion systems to secondary organic aerosol production and ultimately ambient PM levels. PMID:22732009

  9. The effects of bronchodilator-inhaler aerosol propellants on respiratory gas monitors.

    PubMed

    Elliot, W R; Raemer, D B; Goldman, D B; Philip, J H

    1991-04-01

    Spurious readings from a mass spectrometer have been reported following the administration of aerosol bronchodilators. We quantified the response of various respiratory gas analyzers to the aerosol propellant of albuterol inhalant (Proventil). The mass spectrometer systems tested, two Advantage systems, a SARA system, and a Model 6000 Ohmeda system, all displayed artifactual readings in response to the albuterol propellant. Each metered dose of the Proventil brand of albuterol contains 4 ml of Freon 11 (trichloromonofluoromethane) and 11 ml of Freon 12 (dichlorodifluoromethane). The concentration of propellant was expressed in doses/L, where each liter of gas contains 0.4 vol % of Freon 11 and 1.1 vol % of Freon 12 per dose. In proportion to the concentration of albuterol propellant, the two Advantage systems showed substantial readings of isoflurane (%) when no isoflurane was present (13% and 16% per dose/L) and reduced readings of enflurane (-8% and -10% per dose/L) and carbon dioxide (CO2) (-3 and +5 mm Hg per dose/L). The SARA system showed substantial CO2 readings when no CO2 was present (5 mm Hg per dose/L) and displayed small enflurane readings (0.1% per dose/L) when no enflurane was present. The Model 6000 unit showed CO2 readings when no CO2 was present (5 mm Hg per dose/L). Neither the Raman spectrometer, the infrared spectrometers, nor the piezoadsorptive analyzer we tested showed an artifactual effect of albuterol propellant on any of its readings. Simulation and clinical tests demonstrated that a single dose of albuterol propellant into a breathing circuit at the onset of inspiration resulted in concentrations of 0.8 and 0.3 dose/L, respectively.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1906529

  10. Fuel composition and secondary organic aerosol formation: gas-turbine exhaust and alternative aviation fuels.

    PubMed

    Miracolo, Marissa A; Drozd, Greg T; Jathar, Shantanu H; Presto, Albert A; Lipsky, Eric M; Corporan, Edwin; Robinson, Allen L

    2012-08-01

    A series of smog chamber experiments were performed to investigate the effects of fuel composition on secondary particulate matter (PM) formation from dilute exhaust from a T63 gas-turbine engine. Tests were performed at idle and cruise loads with the engine fueled on conventional military jet fuel (JP-8), Fischer-Tropsch synthetic jet fuel (FT), and a 50/50 blend of the two fuels. Emissions were sampled into a portable smog chamber and exposed to sunlight or artificial UV light to initiate photo-oxidation. Similar to previous studies, neat FT fuel and a 50/50 FT/JP-8 blend reduced the primary particulate matter emissions compared to neat JP-8. After only one hour of photo-oxidation at typical atmospheric OH levels, the secondary PM production in dilute exhaust exceeded primary PM emissions, except when operating the engine at high load on FT fuel. Therefore, accounting for secondary PM production should be considered when assessing the contribution of gas-turbine engine emissions to ambient PM levels. FT fuel substantially reduced secondary PM formation in dilute exhaust compared to neat JP-8 at both idle and cruise loads. At idle load, the secondary PM formation was reduced by a factor of 20 with the use of neat FT fuel, and a factor of 2 with the use of the blend fuel. At cruise load, the use of FT fuel resulted in no measured formation of secondary PM. In every experiment, the secondary PM was dominated by organics with minor contributions from sulfate when the engine was operated on JP-8 fuel. At both loads, FT fuel produces less secondary organic aerosol than JP-8 because of differences in the composition of the fuels and the resultant emissions. This work indicates that fuel reformulation may be a viable strategy to reduce the contribution of emissions from combustion systems to secondary organic aerosol production and ultimately ambient PM levels.

  11. Comparison of gravimetric and gas chromatographic methods for assessing performance of textile materials against liquid pesticide penetration.

    PubMed

    Shaw, Anugrah; Abbi, Ruchika

    2004-01-01

    Penetration of liquid pesticides through textile materials is a criterion for determining the performance of protective clothing used by pesticide handlers. The pipette method is frequently used to apply liquid pesticides onto textile materials to measure penetration. Typically, analytical techniques such as Gas Chromatography (GC) are used to measure percentage penetration. These techniques are labor intensive and costly. A simpler gravimetric method was developed, and tests were conducted to compare the gravimetric and GC methods of analysis. Three types of pesticide formulations and 4 fabrics were used for the study. Diluted pesticide formulations were pipetted onto the test specimens and percentage penetration was measured using the 2 methods. For homogeneous formulation, the results of the two methods were fairly comparable. However, due to the filtering action of the textile materials, there were differences in the percentage penetration between the 2 methods for formulations that were not homogeneous.

  12. Gas chromatographic and mass spectrometric determination of chlorophenoxy acids and related herbicides as their (cyanoethyl)dimethylsilyl derivatives

    SciTech Connect

    Bertrand, M.J.; Ahmed, A.W.; Sarrasin, B.; Mallet, V.N.

    1987-05-01

    A method for using (2-cyanoethyl)dimethyl(diethylamino)silane to form derivatives with phenoxy acid herbicides and related compounds is presented. Results obtained with 18 compounds demonstrate that the reaction is quantitative and complete within minutes at room temperature. The derivatives formed can readily be analyzed by gas chromatography using a selective nitrogen-phosphorus detector which eliminates the need for rigorous cleanup of the sample required for detection by electron capture. Response-concentration plots show that detection is linear over several decades with limits of detection being in the low picogram range for all compounds studied. Mass spectral analysis of the derivatives of the 18 compounds studied indicates that the spectra are highly specific showing characteristic ions at (M-54), (M-82), and or (M-98) which are useful for structure confirmation or analysis at low levels by using selected ion monitoring. The analytical advantages of the approach for the analysis of acid herbicides are discussed.

  13. Fabrication of zeolitic imidazolate framework-8-methacrylate monolith composite capillary columns for fast gas chromatographic separation of small molecules.

    PubMed

    Yusuf, Kareem; Badjah-Hadj-Ahmed, Ahmed Yacine; Aqel, Ahmad; ALOthman, Zeid Abdullah

    2015-08-01

    A composite zeolitic imidazolate framework-8 (ZIF-8) with a butyl methacrylate-co-ethylene dimethacrylate (BuMA-co-EDMA) monolithic capillary column (33.5cm long×250μm i.d.) was fabricated to enhance the separation efficiency of methacrylate monoliths toward small molecules using conventional low-pressure gas chromatography in comparison with a neat butyl methacrylate-co-ethylene dimethacrylate (BuMA-co-EDMA) monolithic capillary column (33.5cm long×250μm i.d.). The addition of 10mgmL(-1) ZIF-8 micro-particles increased the BET surface area of BuMA-co-EDMA by 3.4-fold. A fast separation of five linear alkanes in 36s with high resolution (Rs≥1.3) was performed using temperature program. Isothermal separation of the same sample also showed a high efficiency (3315platesm(-1) for octane) at 0.89min. Moreover, the column was able to separate skeletal isomers, such as iso-octane/octane and 2-methyl octane/nonane. In addition, an iso-butane/iso-butylene gas mixture was separated at ambient temperature. Comparison with an open tubular TR-5MS column (30m long×250μm i.d.) revealed the superiority of the composite column in separating the five-membered linear alkane mixture with 4-5 times increase in efficiency and a total separation time of 0.89min instead of 4.67min. A paint thinner sample was fully separated using the composite column in 2.43min with a good resolution (Rs≥0.89). The perfect combination between the polymeric monolith, with its high permeability, and ZIF-8, with its high surface area and flexible 0.34nm pore openings, led to the fast separation of small molecules with high efficiency and opened a new horizon in GC applications.

  14. Fabrication of zeolitic imidazolate framework-8-methacrylate monolith composite capillary columns for fast gas chromatographic separation of small molecules.

    PubMed

    Yusuf, Kareem; Badjah-Hadj-Ahmed, Ahmed Yacine; Aqel, Ahmad; ALOthman, Zeid Abdullah

    2015-08-01

    A composite zeolitic imidazolate framework-8 (ZIF-8) with a butyl methacrylate-co-ethylene dimethacrylate (BuMA-co-EDMA) monolithic capillary column (33.5cm long×250μm i.d.) was fabricated to enhance the separation efficiency of methacrylate monoliths toward small molecules using conventional low-pressure gas chromatography in comparison with a neat butyl methacrylate-co-ethylene dimethacrylate (BuMA-co-EDMA) monolithic capillary column (33.5cm long×250μm i.d.). The addition of 10mgmL(-1) ZIF-8 micro-particles increased the BET surface area of BuMA-co-EDMA by 3.4-fold. A fast separation of five linear alkanes in 36s with high resolution (Rs≥1.3) was performed using temperature program. Isothermal separation of the same sample also showed a high efficiency (3315platesm(-1) for octane) at 0.89min. Moreover, the column was able to separate skeletal isomers, such as iso-octane/octane and 2-methyl octane/nonane. In addition, an iso-butane/iso-butylene gas mixture was separated at ambient temperature. Comparison with an open tubular TR-5MS column (30m long×250μm i.d.) revealed the superiority of the composite column in separating the five-membered linear alkane mixture with 4-5 times increase in efficiency and a total separation time of 0.89min instead of 4.67min. A paint thinner sample was fully separated using the composite column in 2.43min with a good resolution (Rs≥0.89). The perfect combination between the polymeric monolith, with its high permeability, and ZIF-8, with its high surface area and flexible 0.34nm pore openings, led to the fast separation of small molecules with high efficiency and opened a new horizon in GC applications. PMID:26141277

  15. On measurements of aerosol-gas composition of the atmosphere during two expeditions in 2013 along the Northern Sea Route

    NASA Astrophysics Data System (ADS)

    Sakerin, S. M.; Bobrikov, A. A.; Bukin, O. A.; Golobokova, L. P.; Pol'kin, Vas. V.; Pol'kin, Vik. V.; Shmirko, K. A.; Kabanov, D. M.; Khodzher, T. V.; Onischuk, N. A.; Pavlov, A. N.; Potemkin, V. L.; Radionov, V. F.

    2015-11-01

    We presented the results of expedition measurements of the set of physical-chemical characteristics of atmospheric aerosol in areas of the Arctic and Far East seas, performed onboard RV Akademik Fedorov (17 August-22 September 2013) and RV Professor Khljustin (24 July-7 September 2013). The specific features of spatial distribution and time variations of aerosol optical depth (AOD) of the atmosphere in the wavelength range of 0.34-2.14 μm and boundary layer height, aerosol and black carbon mass concentrations, and disperse and chemical composition of aerosol are discussed. Over the Arctic Ocean (on the route of RV Akademik Fedorov) there is a decrease in aerosol and black carbon concentrations in a northeastern direction: higher values were observed in the region of Spitsbergen and near the Kola Peninsula; and minimum values were observed at northern margins of the Laptev Sea. Average AOD (0.5 μm) values in this remote region were 0.03; the aerosol and black carbon mass concentrations were 875 and 22 ng m-3, respectively. The spatial distributions of most aerosol characteristics over Far East seas show their latitudinal decrease in the northern direction. On transit of RV Professor Khljustin from the Japan Sea to the Chukchi Sea, the aerosol number concentration decreased on average from 23.7 to 2.5 cm-3, the black carbon mass concentration decreased from 150 to 50 ng m-3, and AOD decreased from 0.19 to 0.03. We analyzed the variations in the boundary layer height, measured by ship-based lidar: the average value was 520 m, and the maximal value was 1200 m. In latitudinal distribution of the boundary layer height, there is a characteristic minimum at a latitude of ~ 55° N. For water basins of eight seas, we present the chemical compositions of the water-soluble aerosol fraction (ions, elements) and small gas-phase species, as well as estimates of their vertical fluxes. It is shown that substances are mainly (75-89 %) supplied from the atmosphere to the sea

  16. Comparison of a jet separator and an open splitter as an interface between a multi-capillary gas chromatographic column and a time-of-flight mass spectrometer

    PubMed

    Pongpun; Mlynski; Crisp; Guilhaus

    2000-09-01

    A gas chromatographic/time-of-flight mass spectrometric (GC/TOFMS) interface is being developed for fast on-line analysis utilizing multi-capillary column technology. A variable gap-distance jet separator has been constructed and its performance compared with that of a commercially supplied post-column open splitter recommended for use between the multi-capillary column and a mass spectrometer. Both interfaces were found to be compatible with the GC/TOFMS system at high carrier gas flow-rates, facilitating high-speed and high-resolution separations. The systems were investigated and tested with a mixture of volatile organic compounds (VOCs) with molecular masses from 85 to 166: dichloromethane, toluene, m-dichlorobenzene, o-dichlorobenzene and tetrachloroethylene. The optimum tip-to-tip gap distance corresponding to the highest efficiency of the jet separator was found to be 0.030 mm for each compound at carrier gas flow-rates of 20, 40 and 60 ml min(-1) giving, in the ion source housing, ion gauge pressure readings of 1.6 x 10(-6), 5.0 x 10(-6) and 5.8 x 10(-6) mbar, respectively. The efficiency of the jet separator (10-30% yields) was significantly higher than that of the open splitter (6-9% yields). The observation that the open splitter did not provide a constant flow-rate to the ion source was not in agreement with the manufacturer's specifications. A method for measuring the gas flow-rates in all parts of the equipment is described. The correlation between yield in the jet separator and molecular mass for the heterogeneous set of compounds studied was found to be less linear than usually reported for homologous series of compounds in jet separator studies. The result suggests that the pressure conditions in the jet may be sufficient for the separation process to be partly controlled by diffusion rather than predominately by effusion. Copyright 2000 John Wiley & Sons, Ltd.

  17. Gas Chromatographic/Mass Spectrometric Analysis of Volatile Metabolites in Bovine Vaginal Fluid and Assessment of Their Bioactivity

    PubMed Central

    Sankar, R.; Archunan, G.

    2011-01-01

    The chemical profiles of vaginal fluid collected from cows in oestrus and nonoestrus were analysed by gas chromatography-mass spectrometry (GC-MS) to establish any qualitative differences that might have potential value in bovine biocommunication. Eight different organic compounds were detected using the two chromatograms. The chemical profiles of oestrus vaginal fluid were distinguished significantly by the presence of three specific substances, namely, trimethylamine, acetic acid, and propionic acid that were not present in nonoestrus phase. The oestrus specific synthetic compounds were rubbed onto the genital region of nonoestrus animals (dummy cows), and the bulls were allowed to sniff the genital region and observed sexual behaviours. The statistical significance was higher (P < 0.001) in bulls exhibiting repeated flehmen and mounting behaviours towards the mixture of acetic acid, propionic acid, and trimethylamine as compared to test these compounds separately. It was concluded that the volatile substances present in the bovine vaginal fluid during oestrus may act as chemical communicators. PMID:22114602

  18. Study of the Behaviors of Gunshot Residues from Spent Cartridges by Headspace Solid-Phase Microextraction-Gas Chromatographic Techniques.

    PubMed

    Chang, Kah Haw; Yew, Chong Hooi; Abdullah, Ahmad Fahmi Lim

    2015-07-01

    Gunshot residues, produced after shooting activity, have acquired their importance in analysis due to the notoriety of firearms-related crimes. In this study, solid-phase microextraction was performed to extract the headspace composition of spent cartridges using 85-μm polyacrylate fiber at 66°C for 21 min. Organic compounds, that is, naphthalene, 2,6-dinitrotoluene, 2,4-dinitrotoluene, diphenylamine, and dibutyl phthalate were detected and analyzed by gas chromatography-flame ionization detection technique. Evaluation of chromatograms for diphenylamine, dibutyl phthalate, and naphthalene indicates the period after a gunshot was discharged, whether it was 1 days, 2-4 days, <5 days, 10 days, 20 days, or more than 30 days ago. This study revealed the potential effects of environmental factors such as occasional wind blow and direct sunlight on the estimation of time after spent cartridges were discharged. In conclusion, we proposed reliable alternative in analyzing the headspace composition of spent cartridges in a simulated crime scene. PMID:25771708

  19. Metabolism of anabolic steroids by recombinant human cytochrome P450 enzymes. Gas chromatographic-mass spectrometric determination of metabolites.

    PubMed

    Rendic, S; Nolteernsting, E; Schänzer, W

    1999-11-26

    Metabolism of steroid hormones with anabolic properties was studied in vitro using human recombinant CYP3A4, CYP2C9 and 2B6 enzymes. The enzyme formats used for CYP3A4 and CYP2C9 were insect cell microsomes expressing human CYP enzymes and purified recombinant human CYP enzymes in a reconstituted system. CYP3A4 enzyme formats incubated with anabolic steroids, testosterone, 17alpha-methyltestosterone, metandienone, boldenone and 4-chloro-1,2-dehydro-17alpha-methyltestosterone, produced 6beta-hydroxyl metabolites identified as trimethylsilyl (TMS)-ethers by a gas chromatography-mass spectrometry (GC-MS) method. When the same formats of CYP2C9 were incubated with the anabolic steroids, no 6beta-hydroxyl metabolites were formed. Human lymphoblast cell microsomes expressing human CYP2B6 incubated with the steroids investigated produced traces of 6beta-hydroxyl metabolites with testosterone and 17alpha-methyltestosterone only. We suggest that the electronic effects of the 3-keto-4-ene structural moiety contribute to the selectivity within the active site of CYP3A4 enzyme resulting in selective 6beta-hydroxylation. PMID:10630892

  20. Determination of methyl mercury by aqueous phase Eehylation, followed by gas chromatographic separation with cold vapor atomic fluorescence detection

    USGS Publications Warehouse

    De Wild, John F.; Olsen, Mark L.; Olund, Shane D.

    2002-01-01

    A recent national sampling of streams in the United States revealed low methyl mercury concentrations in surface waters. The resulting median and mean concentrations, calculated from 104 samples, were 0.06 nanograms per liter (ng/L) and 0.15 ng/L, respectively. This level of methyl mercury in surface water in the United States has created a need for analytical techniques capable of detecting sub-nanogram per liter concentrations. In an attempt to create a U.S. Geological Survey approved method, the Wisconsin District Mercury Laboratory has adapted a distillation/ethylation/ gas-phase separation method with cold vapor atomic fluorescence spectroscopy detection for the determination of methyl mercury in filtered and unfiltered waters. This method is described in this report. Based on multiple analyses of surface water and ground-water samples, a method detection limit of 0.04 ng/L was established. Precision and accuracy were evaluated for the method using both spiked and unspiked ground-water and surface-water samples. The percent relative standard deviations ranged from 10.2 to 15.6 for all analyses at all concentrations. Average recoveries obtained for the spiked matrices ranged from 88.8 to 117 percent. The precision and accuracy ranges are within the acceptable method-performance limits. Considering the demonstrated detection limit, precision, and accuracy, the method is an effective means to quantify methyl mercury in waters at or below environmentally relevant concentrations

  1. Gas chromatographic-mass spectrometric fragmentation study of phytoestrogens as their trimethylsilyl derivatives: Identification in soy milk and wastewater samples

    USGS Publications Warehouse

    Ferrer, I.; Barber, L.B.; Thurman, E.M.

    2009-01-01

    An analytical method for the identification of eight plant phytoestrogens (biochanin A, coumestrol, daidzein, equol, formononetin, glycitein, genistein and prunetin) in soy products and wastewater samples was developed using gas chromatography coupled with ion trap mass spectrometry (GC/MS-MS). The phytoestrogens were derivatized as their trimethylsilyl ethers with trimethylchlorosilane (TMCS) and N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA). The phytoestrogens were isolated from all samples with liquid-liquid extraction using ethyl acetate. Daidzein-d4 and genistein-d4 labeled standards were used as internal standards before extraction and derivatization. The fragmentation patterns of the phytoestrogens were investigated by isolating and fragmenting the precursor ions in the ion-trap and a typical fragmentation involved the loss of a methyl and a carbonyl group. Two characteristic fragment ions for each analyte were chosen for identification and confirmation. The developed methodology was applied to the identification and confirmation of phytoestrogens in soy milk, in wastewater effluent from a soy-milk processing plant, and in wastewater (influent and effluent) from a treatment plant. Detected concentrations of genistein ranged from 50,000 ??g/L and 2000 ??g/L in soy milk and in wastewater from a soy-plant, respectively, to 20 ??g/L and <1 ??g/L for influent and effluent from a wastewater treatment plant, respectively. ?? 2009 Elsevier B.V.

  2. Capillary gas chromatographic separation of organic bases using a pH-adjusted basic water stationary phase.

    PubMed

    Darko, Ernest; Thurbide, Kevin B

    2016-09-23

    The use of a pH-adjusted water stationary phase for analyzing organic bases in capillary gas chromatography (GC) is demonstrated. Through modifying the phase to typical values near pH 11.5, it is found that various organic bases are readily eluted and separated. Conversely, at the normal pH 7 operating level, they are not. Sodium hydroxide is found to be a much more stable base than ammonium hydroxide for altering the pH due to the higher volatility and evaporation of the latter. In the basic condition, such analytes are not ionized and are observed to produce good peak shapes even for injected masses down to about 20ng. By comparison, analyses on a conventional non-polar capillary GC column yield more peak tailing and only analyte masses of 1μg or higher are normally observed. Through carefully altering the pH, it is also found that the selectivity between analytes can be potentially further enhanced if their respective pKa values differ sufficiently. The analysis of different pharmaceutical and petroleum samples containing organic bases is demonstrated. Results indicate that this approach can potentially offer unique and beneficial selectivity in such analyses.

  3. [Application of Stir Bar Sorptive Extraction and Gas Chromatograph Mass Spectrometer to the Phthalic Acid Esters Analysis in Seawater].

    PubMed

    Gao, Chen-chen; Li, Feng-min; Lu, Lun; Sun, Yue

    2015-10-01

    For the determination of trace amounts of phthalic acid esters (PAEs) in complex seawater matrix, a stir bar sorptive extraction gas chromatography mass spectrometry (SBSE-GC-MS) method was established. Dimethyl phthalate (DMP), diethyl phthalate (DEP), dibutyl phthalate (DBP), butyl benzyl phthalate (BBP), dibutyl phthalate (2-ethylhexyl) phthalate (DEHP) and dioctyl phthalate (DOP) were selected as study objects. The effects of extraction time, amount of methanol, amount of sodium chloride, desorption time and desorption solvent were optimized. The method of SBSE-GC-MS was validated through recoveries and relative standard deviation. The optimal extraction time was 2 h. The optimal methanol content was 10%. The optimal sodium chloride content was 5% . The optimal desorption time was 50 min. The optimal desorption solvent was the mixture of methanol to acetonitrile (4:1, volume: volume). The linear relationship between the peak area and the concentration of PAEs was relevant. The correlation coefficients were greater than 0.997. The detection limits were between 0.25 and 174.42 ng x L(-1). The recoveries of different concentrations were between 56.97% and 124.22% . The relative standard deviations were between 0.41% and 14.39%. On the basis of the method, several estuaries water sample of Jiaozhou Bay were detected. DEP was detected in all samples, and the concentration of BBP, DEHP and DOP were much higher than the rest. PMID:26841630

  4. Capillary gas chromatographic separation of organic bases using a pH-adjusted basic water stationary phase.

    PubMed

    Darko, Ernest; Thurbide, Kevin B

    2016-09-23

    The use of a pH-adjusted water stationary phase for analyzing organic bases in capillary gas chromatography (GC) is demonstrated. Through modifying the phase to typical values near pH 11.5, it is found that various organic bases are readily eluted and separated. Conversely, at the normal pH 7 operating level, they are not. Sodium hydroxide is found to be a much more stable base than ammonium hydroxide for altering the pH due to the higher volatility and evaporation of the latter. In the basic condition, such analytes are not ionized and are observed to produce good peak shapes even for injected masses down to about 20ng. By comparison, analyses on a conventional non-polar capillary GC column yield more peak tailing and only analyte masses of 1μg or higher are normally observed. Through carefully altering the pH, it is also found that the selectivity between analytes can be potentially further enhanced if their respective pKa values differ sufficiently. The analysis of different pharmaceutical and petroleum samples containing organic bases is demonstrated. Results indicate that this approach can potentially offer unique and beneficial selectivity in such analyses. PMID:27578412

  5. Gas chromatographic and mass spectrometric analysis of 36 lignin-related methoxyphenols from uncontrolled combustion of wood.

    PubMed

    Kjällstrand, J; Ramnäs, O; Petersson, G

    1998-10-23

    Eighteen 4-hydroxy-3-methoxyphenyl (guaiacyl) compounds in wood smoke from spruce, and 18 4-hydroxy-3,5-dimethoxyphenyl (syringyl) analogues in birchwood smoke were analysed. Smoke samples were taken by a gas syringe from wood burning under varying but more or less choked conditions in laboratory pot experiments. Retention index data for a methylsilicone column and basic mass spectral data are given for all compounds. Retention index in combination with molecular mass and structure-specific fragment ions greatly facilitates qualitative analysis. The syringyl and guaiacyl analogues differ by 240 units in retention index and the matching structure-specific ions in their mass spectra by 30 mass units. The identified methoxyphenols differ in the structure of the sidechain, which may be lacking, an alkyl group, an alkenyl group, a carbonyl-containing group or an alcoholic moiety. The proportions between these groups of compounds varied strongly with combustion conditions whereas the proportions of phenols within them were quite specific for each group. The phenols with reactive olefinic linkages in the sidechain were present in larger proportions than reported in other studies of methoxyphenols. PMID:9818433

  6. Does further clean-up reduce the matrix enhancement effect in gas chromatographic analysis of pesticide residues in food?

    PubMed

    Schenck, F J; Lehotay, S J

    2000-01-28

    Sample extracts of apples, peas, green beans, oranges, raspberries, clementines, carrots, and wheat obtained using the Food and Drug Administration (acetone extraction) and Canadian Pest Management Regulatory Agency (acetonitrile extraction) multiresidue methods for pesticides were subjected to clean-up using different solid-phase extraction (SPE) cartridges in an attempt to reduce or eliminate the matrix enhancement effect. The matrix enhancement effect is related to the blocking of active sites on the injector liner by matrix components, thereby increasing signal in the presence of matrix versus standards in solvent in which the pesticides themselves interact with the active sites. Graphitized carbon black (GCB) was often used in combination with various anion-exchange SPE cartridges. The extracts were then spiked with organophosphorus insecticides. These process standards were then compared to standards in acetone of the same concentration using gas chromatography with flame photometric detection or ion trap mass spectrometric detection. Sample matrix enhancement varied from little to no effect for some pesticides (e.g. chlorpyrifos, malathion) to >200% in the case of certain susceptible pesticides. The GCB removed color components but showed little effect in reducing matrix enhancement by itself. The anion-exchange cartridges in combination with GCB or not, substantially reduced the matrix enhancement effect but did not eliminate it. PMID:10677079

  7. Multiresidue analysis of pesticides in fruits and vegetables using solid-phase extraction and gas chromatographic methods.

    PubMed

    Lal, Asha; Tan, Guanhuat; Chai, Meekin

    2008-02-01

    A new extraction and cleanup procedure with gas chromatography was developed for the sensitive determination of acephate, dimethoate, malathion, diazinon, quinalphos, chlorpyrifos, profenofos, alpha-endosulfan, beta-endosulfan, chlorothalonil and carbaryl using 1-chloro-4-fluorobenzene as an internal standard in fruits and vegetables. Several extracting and eluting solvents for solid-phase extraction were investigated. The overall extracting solvent with a mixture of acetone:ethyl acetate:hexane (10:80:10, v/v/v) and a eluting solvent of 5% acetone in hexane used with the RPC18 cartridge gave the best recovery for all of the investigated pesticides, and minimized the interference from co-extractants. Under the optimal extraction and clean-up conditions, recoveries of 85 - 99% with RSD < 5.0% (n = 3) for most of the pesticides at the 0.02 - 0.5 mg/kg level were obtained. The limit of detection was between 0.005 - 0.01 mg/kg and the limit of quantification was 0.01 mg/kg. This analytical procedure was characterized with high accuracy and acceptable sensitivity to meet requirements for monitoring pesticides in crops. PMID:18270414

  8. Influence of oxygen addition to the carrier gas on laser-induced breakdown spectroscopy measurements on aerosols

    NASA Astrophysics Data System (ADS)

    Palazzo, N.; Migliorini, F.; Dondè, R.; Maffi, S.; De Iuliis, S.

    2016-01-01

    In this work, laser-induced breakdown spectrosopy is implemented on aerosol particles for absolute concentration analysis. The aim of this work is the investigation of the effect of the bath gas used for nebulizing the aerosol. Nitrogen, air, and 50% O2 in N2 mixture have been chosen as carrier gasses in order to analyze the effect of oxygen addition to the gas. LIBS measurements have been carried out on aerosol particles produced from CuCl2 2H2O solutions, and the 324.7 nm Cu line is considered. As a first analysis, plasma parameters, such as temperature and electron density, have been evaluated changing the carrier gas. Measurements to derive the LIBS calibration curve of the 324.7 nm Cu line are carried out in air and in N2. The significant difference in the slope of the resulting calibration curves has to be attributed to the oxygen addition to the bath gas. To explore such behavior, time-resolved measurements of the Cu line and peak/base ratio have been performed. The presence of two competitive effects have been observed that becomes significant increasing the amount of oxygen in the carrier gas. One is the oxygen-quenching effect, already observed in the literature, and the other one is the enhancement of the Cu LIBS signal, expecially at short delay times. These effects have been observed also at other Cu lines and changing the analyte source. The results are presented and widely discussed.

  9. Target urinary analytes for the gas chromatographic- mass spectrometric detection of procyclidine and benzhexol in drug abuse cases.

    PubMed

    El-Haj, Babiker; Al-Amri, Abdulkader; Ali, Heyam Saad

    2011-03-01

    The two antiparkinsonian drugs procyclidine and benzhexol are presently finding considerable favor for their euphoric hallucinogenic effects among drug abusers in some countries. In anticipation of their possible scheduling in national drug laws, gas chromatography-mass spectrometry (GC-MS) methods for their detection in urine will be required. However, because of uncertainty of the metabolic fate of the two drugs in humans, the urinary target analytes for GC-MS detection were not well defined. The problem was addressed in the present study in which it was found that mono-hydroxy metabolites, where hydroxylation took place at the cyclohexane ring in both drugs, could be endorsed as the major target analytes. The metabolites could only be detected as the mono- and/or di-trimethylsilyl (TMS) derivatives. The predominance of either derivative depended on the temperature and time of heating with the derivatizing reagent. Because of the basic properties of the hydroxy metabolites, analytic method optimization was needed for their detection in urine included extraction under basic pH conditions. Urine hydrolysis with β-glucuronidase did not have an effect on the recovery of the metabolites, but was usually performed in search for other drugs. Because of the relative abundance of ions, the electron impact mass spectra of the mono-TMS derivatives and the chemical ionization (CI) mass spectra of the mono- and di-TMS derivatives of the hydroxy metabolites of both drugs were found to be more structurally informative. The CI mass spectra of the di- TMS derivatives have the additive advantage of being potentially useful for quantitative analysis.

  10. An analytical method for trifluoroacetic Acid in water and air samples using headspace gas chromatographic determination of the methyl ester.

    PubMed

    Zehavi, D; Seiber, J N

    1996-10-01

    An analytical method has been developed for the determination of trace levels of trifluoroacetic acid (TFA), an atmospheric breakdown product of several of the hydrofluorocarbon (HFC) and hydrochlorofluorocarbon (HCFC) replacements for the chlorofluorocarbon (CFC) refrigerants, in water and air. TFA is derivatized to the volatile methyl trifluoroacetate (MTFA) and determined by automated headspace gas chromatography (HSGC) with electron-capture detection or manual HSGC using GC/MS in the selected ion monitoring (SIM) mode. The method is based on the reaction of an aqueous sample containing TFA with dimethyl sulfate (DMS) in concentrated sulfuric acid in a sealed headspace vial under conditions favoring distribution of MTFA to the vapor phase. Water samples are prepared by evaporative concentration, during which TFA is retained as the anion, followed by extraction with diethyl ether of the acidified sample and then back-extraction of TFA (as the anion) in aqueous bicarbonate solution. The extraction step is required for samples with a relatively high background of other salts and organic materials. Air samples are collected in sodium bicarbonate-glycerin-coated glass denuder tubes and prepared by rinsing the denuder contents with water to form an aqueous sample for derivatization and analysis. Recoveries of TFA from spiked water, with and without evaporative concentration, and from spiked air were quantitative, with estimated detection limits of 10 ng/mL (unconcentrated) and 25 pg/mL (concentrated 250 mL:1 mL) for water and 1 ng/m(3) (72 h at 5 L/min) for air. Several environmental air, fogwater, rainwater, and surface water samples were successfully analyzed; many showed the presence of TFA. PMID:21619278

  11. Computation of Phase Equilibria, State Diagrams and Gas/Particle Partitioning of Mixed Organic-Inorganic Aerosols

    NASA Astrophysics Data System (ADS)

    Zuend, A.; Marcolli, C.; Peter, T.

    2009-04-01

    The chemical composition of organic-inorganic aerosols is linked to several processes and specific topics in the field of atmospheric aerosol science. Photochemical oxidation of organics in the gas phase lowers the volatility of semi-volatile compounds and contributes to the particulate matter by gas/particle partitioning. Heterogeneous chemistry and changes in the ambient relative humidity influence the aerosol composition as well. Molecular interactions between condensed phase species show typically non-ideal thermodynamic behavior. Liquid-liquid phase separations into a mainly polar, aqueous and a less polar, organic phase may considerably influence the gas/particle partitioning of semi-volatile organics and inorganics (Erdakos and Pankow, 2004; Chang and Pankow, 2006). Moreover, the phases present in the aerosol particles feed back on the heterogeneous, multi-phase chemistry, influence the scattering and absorption of radiation and affect the CCN ability of the particles. Non-ideal thermodynamic behavior in mixtures is usually described by an expression for the excess Gibbs energy, enabling the calculation of activity coefficients. We use the group-contribution model AIOMFAC (Zuend et al., 2008) to calculate activity coefficients, chemical potentials and the total Gibbs energy of mixed organic-inorganic systems. This thermodynamic model was combined with a robust global optimization module to compute potential liquid-liquid (LLE) and vapor-liquid-liquid equilibria (VLLE) as a function of particle composition at room temperature. And related to that, the gas/particle partitioning of semi-volatile components. Furthermore, we compute the thermodynamic stability (spinodal limits) of single-phase solutions, which provides information on the process type and kinetics of a phase separation. References Chang, E. I. and Pankow, J. F.: Prediction of activity coefficients in liquid aerosol particles containing organic compounds, dissolved inorganic salts, and water - Part

  12. Regional comparison of technetium-99m DTPA aerosol and radioactive gas ventilation (xenon and krypton) studies in patients with suspected pulmonary embolism

    SciTech Connect

    Ramanna, L.; Alderson, P.O.; Waxman, A.D.; Berman, D.S.; Brachman, M.B.; Kroop, S.A.; Goldsmith, M.; Tanasescu, D.E.

    1986-09-01

    The regional distribution of (99mTc)DTPA aerosol was compared with that of /sup 133/Xe (n = 30) and krypton (n = 24) in a group of patients with suspected pulmonary embolism. All patients had an aerosol study using a recently available commercial generator system, a ventilation study with one of the gases, and perfusion imaging. Regional information was assessed visually on xenon, krypton, and aerosol studies independently by considering each lung as three equal-sized zones. In addition, gas ventilation findings peripheral to regions of aerosol turbulence (hot spots) were evaluated. Only 64% of the zones were in complete agreement on xenon and aerosol. Most of the discordance between xenon and aerosol was accounted for by minor degrees of /sup 133/Xe washout retention in zones that appeared normal in the aerosol study. An agreement rate of 85% was noted between 81mKr and aerosol regionally. The regions of discordance between aerosol and gas studies, however, usually were associated with unimpressive perfusion defects that did not change the scintigraphic probability for pulmonary embolism in any patient. Regarding zones of aerosol hyperdeposition, 76% had associated washout abnormalities on xenon; however, there was no correlation between the presence of these abnormalities or perfusion abnormalities. The results confirm the high sensitivity of /sup 133/Xe washout imaging, but suggest that radioaerosol imaging will detect most parenchymal abnormalities associated with perfusion defects of significance.

  13. Gas-particle partitioning of primary organic aerosol emissions: (2) diesel vehicles.

    PubMed

    May, Andrew A; Presto, Albert A; Hennigan, Christopher J; Nguyen, Ngoc T; Gordon, Timothy D; Robinson, Allen L

    2013-08-01

    Experiments were performed to investigate the gas-particle partitioning of primary organic aerosol (POA) emissions from two medium-duty (MDDV) and three heavy-duty (HDDV) diesel vehicles. Each test was conducted on a chassis dynamometer with the entire exhaust sampled into a constant volume sampler (CVS). The vehicles were operated over a range of driving cycles (transient, high-speed, creep/idle) on different ultralow sulfur diesel fuels with varying aromatic content. Four independent yet complementary approaches were used to investigate POA gas-particle partitioning: artifact correction of quartz filter samples, dilution from the CVS into a portable environmental chamber, heating in a thermodenuder, and thermal desorption/gas chromatography/mass spectrometry (TD-GC-MS) analysis of quartz filter samples. During tests of vehicles not equipped with diesel particulate filters (DPF), POA concentrations inside the CVS were a factor of 10 greater than ambient levels, which created large and systematic partitioning biases in the emissions data. For low-emitting DPF-equipped vehicles, as much as 90% of the POA collected on a quartz filter from the CVS were adsorbed vapors. Although the POA emission factors varied by more than an order of magnitude across the set of test vehicles, the measured gas-particle partitioning of all emissions can be predicted using a single volatility distribution derived from TD-GC-MS analysis of quartz filters. This distribution is designed to be applied directly to quartz filter data that are the basis for existing emissions inventories and chemical transport models that have implemented the volatility basis set approach.

  14. Organic aerosol molecular composition and gas-particle partitioning coefficients at a Mediterranean site (Corsica).

    PubMed

    Rossignol, Stéphanie; Couvidat, Florian; Rio, Caroline; Fable, Sébastien; Grignion, Guillaume; Savelli; Pailly, Olivier; Leoz-Garziandia, Eva; Doussin, Jean-Francois; Chiappini, Laura

    2016-02-01

    Molecular speciation of atmospheric organic matter was investigated during a short summer field campaign performed in a citrus fruit field in northern Corsica (June 2011). Aimed at assessing the performance on the field of newly developed analytical protocols, this work focuses on the molecular composition of both gas and particulate phases and provides an insight into partitioning behavior of the semi-volatile oxygenated fraction. Limonene ozonolysis tracers were specifically searched for, according to gas chromatography-mass spectrometry (GC-MS) data previously recorded for smog chamber experiments. A screening of other oxygenated species present in the field atmosphere was also performed. About sixty polar molecules were positively or tentatively identified in gas and/or particle phases. These molecules comprise a wide range of branched and linear, mono and di-carbonyls (C3-C7), mono and di-carboxylic acids (C3-C18), and compounds bearing up to three functionalities. Among these compounds, some can be specifically attributed to limonene oxidation and others can be related to α- or β-pinene oxidation. This provides an original snapshot of the organic matter composition at a Mediterranean site in summer. Furthermore, for compounds identified and quantified in both gaseous and particulate phases, an experimental gas/particle partitioning coefficient was determined. Several volatile products, which are not expected in the particulate phase assuming thermodynamic equilibrium, were nonetheless present in significant concentrations. Hypotheses are proposed to explain these observations, such as the possible aerosol viscosity that could hinder the theoretical equilibrium to be rapidly reached.

  15. Organic aerosol molecular composition and gas-particle partitioning coefficients at a Mediterranean site (Corsica).

    PubMed

    Rossignol, Stéphanie; Couvidat, Florian; Rio, Caroline; Fable, Sébastien; Grignion, Guillaume; Savelli; Pailly, Olivier; Leoz-Garziandia, Eva; Doussin, Jean-Francois; Chiappini, Laura

    2016-02-01

    Molecular speciation of atmospheric organic matter was investigated during a short summer field campaign performed in a citrus fruit field in northern Corsica (June 2011). Aimed at assessing the performance on the field of newly developed analytical protocols, this work focuses on the molecular composition of both gas and particulate phases and provides an insight into partitioning behavior of the semi-volatile oxygenated fraction. Limonene ozonolysis tracers were specifically searched for, according to gas chromatography-mass spectrometry (GC-MS) data previously recorded for smog chamber experiments. A screening of other oxygenated species present in the field atmosphere was also performed. About sixty polar molecules were positively or tentatively identified in gas and/or particle phases. These molecules comprise a wide range of branched and linear, mono and di-carbonyls (C3-C7), mono and di-carboxylic acids (C3-C18), and compounds bearing up to three functionalities. Among these compounds, some can be specifically attributed to limonene oxidation and others can be related to α- or β-pinene oxidation. This provides an original snapshot of the organic matter composition at a Mediterranean site in summer. Furthermore, for compounds identified and quantified in both gaseous and particulate phases, an experimental gas/particle partitioning coefficient was determined. Several volatile products, which are not expected in the particulate phase assuming thermodynamic equilibrium, were nonetheless present in significant concentrations. Hypotheses are proposed to explain these observations, such as the possible aerosol viscosity that could hinder the theoretical equilibrium to be rapidly reached. PMID:26969549

  16. SAGE ground truth plan: Correlative measurements for the Stratospheric Aerosol and Gas Experiment (SAGE) on the AEM-B satellite

    NASA Technical Reports Server (NTRS)

    Russell, P. B. (Editor); Cunnold, D. M.; Grams, G. W.; Laver, J.; Mccormick, M. P.; Mcmaster, L. R.; Murcray, D. G.; Pepin, T. J.; Perry, T. W.; Planet, W. G.

    1979-01-01

    The ground truth plan is outlined for correlative measurements to validate the Stratospheric Aerosol and Gas Experiment (SAGE) sensor data. SAGE will fly aboard the Applications Explorer Mission-B satellite scheduled for launch in early 1979 and measure stratospheric vertical profiles of aerosol, ozone, nitrogen dioxide, and molecular extinction between 79 N and 79 S. latitude. The plan gives details of the location and times for the simultaneous satellite/correlative measurements for the nominal launch time, the rationale and choice of the correlative sensors, their characteristics and expected accuracies, and the conversion of their data to extinction profiles. In addition, an overview of the SAGE expected instrument performance and data inversion results are presented. Various atmospheric models representative of stratospheric aerosols and ozone are used in the SAGE and correlative sensor analyses.

  17. Development, Application, and Transition of Aerosol and Trace Gas Products Derived from Next-Generation Satellite Observations to Operations

    NASA Technical Reports Server (NTRS)

    Berndt, Emily; Naeger, Aaron; Zavodsky, Bradley; McGrath, Kevin; LaFontaine, Frank

    2016-01-01

    NASA Short-term Prediction Research and Transition (SPoRT) Center has a history of successfully transitioning unique observations and research capabilities to the operational weather community to improve short-term forecasts. SPoRTstrives to bridge the gap between research and operations by maintaining interactive partnerships with end users to develop products that match specific forecast challenges, provide training, and assess the products in the operational environment. This presentation focuses on recent product development, application, and transition of aerosol and trace gas products to operations for specific forecasting applications. Recent activities relating to the SPoRT ozone products, aerosol optical depth composite product, sulfur dioxide, and aerosol index products are discussed.

  18. New gas chromatographic-mass spectrometric method for the determination of urinary pyrethroid metabolites in environmental medicine.

    PubMed

    Schettgen, T; Koch, H M; Drexler, H; Angerer, J

    2002-10-01

    We have developed and validated a new, reliable and very sensitive method for the determination of the urinary metabolites of the most common pyrethroids in one analytical run. After acidic hydrolysis for the cleavage of conjugates, the analytes cis-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (cis-Cl(2)CA), trans-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (trans-Cl(2)CA), cis-3-(2,2-dibromovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (Br(2)CA), 4-fluoro-3-phenoxybenzoic acid (F-PBA) and 3-phenoxybenzoic acid (3-PBA) were extracted from the matrix with a liquid-liquid extraction procedure using n-hexane under acidic conditions. For further clean-up, NaOH was added to the organic phase and the carboxylic acids were re-extracted into the aqueous phase. After acidification and extraction into n-hexane again, the metabolites were then derivatised to volatile esters using N-tert.-butyldimethylsilyl-N-methyltrifluoroacetamid (MTBSTFA). Separation and detection were carried out using capillary gas chromatography with mass-selective detection (GC-MS). 2-Phenoxybenzoic acid (2-PBA) served as internal standard for the quantification of the pyrethroid metabolites. The limit of detection for all analytes was 0.05 microg/l urine. The RSD of the within-series imprecision was between 2.0 and 5.4% at a spiked concentration of 0.4 microg/l and the relative recovery was between 79.3 and 93.4%, depending on the analyte. This method was used for the analysis of urine samples of 46 persons from the general population without known exposure to pyrethroids. The metabolites cis-Cl(2)CA, trans-Cl(2)CA and 3-PBA could be found in 52, 72 and 70% of all samples with median values of 0.06, 0.11 and 0.16 microg/l, respectively. Br(2)CA and F-PBA could also be detected in 13 and 4% of the urine samples. PMID:12376120

  19. Gas chromatographic determination of ethyl glucuronide in hair: comparison between tandem mass spectrometry and single quadrupole mass spectrometry.

    PubMed

    Cappelle, Delphine; Neels, Hugo; Yegles, Michel; Paulus, Jeff; van Nuijs, Alexander L N; Covaci, Adrian; Crunelle, Cleo L

    2015-04-01

    Ethyl glucuronide (EtG), a minor metabolite of ethanol, accumulates in hair and is currently used as a long-term marker for the detection of chronic and excessive alcohol consumption. Sensitive methods are required to differentiate teetotalers from moderate drinkers according to the established cut-off (i.e., 7 pg/mg hair). The aim of this study was to develop a sensitive method using gas chromatography coupled to tandem mass spectrometry (GC-MS/MS) operated in the negative ion chemical ionization (NICI) mode. The validated method was applied to hair samples from teetotalers, moderate and excessive alcohol consumers, and results were compared to a previously validated GC-NICI-MS method. The developed GC-NICI-MS/MS method showed linearity over a range from 2 to 400 pg/mg hair, with a limit of detection (LOD) of 0.05 pg/mg hair and a lower limit of quantification (LLOQ) of 0.2 pg/mg hair, compared to an LOD of 0.5 pg/mg hair and LLOQ of 1.5 pg/mg hair obtained with GC-NICI-MS. Furthermore, lower background noise was observed using GC-NICI-MS/MS. Comparison of results of hair samples (n=58) obtained by GC-NICI-MS and GC-NICI-MS/MS showed no significant difference between both methods (paired-sample t-test, p>0.05; mean CV=1.0%). The differences between both methods were larger for EtG concentrations<30 mg/pg hair (mean CV=1.7%) than for EtG concentrations>30 mg/pg hair (mean CV=0.7%). This suggests a higher selectivity of GC-NICI-MS/MS at lower concentrations. In conclusion, by using GC-NICI-MS/MS, a higher analytical selectivity and an improved signal to noise ratio, can be achieved. Although GC-NICI-MS would not change the interpretation of the EtG concentrations, the present GC-NICI-MS/MS method should preferentially be used for the determination of EtG in hair, especially when differentiating between teetotalers and moderate drinkers according to the current cut-off (i.e., 7 pg/mg hair). PMID:25562794

  20. Method for measuring changes in the atmospheric O2/N2 ratio by a gas chromatograph equipped with a thermal conductivity detector

    NASA Astrophysics Data System (ADS)

    Tohjima, Yasunori

    2000-06-01

    We present a method for measuring changes in the atmospheric O2/N2 ratio based on data from a gas chromatograph (GC) equipped with a thermal conductivity detector (TCD). In this method, O2 and N2 in an air sample are separated on a column filled with molecular sieve 5A with H2 carrier gas. Since the separated O2 includes Ar, which has a retention time similar to that of O2, the (O2+Ar)/N2 ratio is actually measured. The change in the measured (O2+Ar)/N2 ratio can be easily converted to that in the O2/N2 ratio with a very small error based on the fact that the atmospheric Ar/N2 ratio is almost constant. The improvements to achieve the high-precision measurement include stabilization of the pressure at the GC column head and at the outlets of the TCD and the sample loop. Additionally, the precision is improved statistically by repeating alternate analyses of sample and a reference gas. The standard deviation of the replicate cycles of reference and sample analyses is about 18 per meg (corresponding to 3.8 parts per million (ppm) O2 in air). This means that the standard error is about 7 per meg (1.5 ppm O2 in air) for seven cycles of alternate analyses, which takes about 70 min. The response of this method is likely to have a 2% nonlinearity. Ambient air samples are collected under pressure in glass flasks equipped with two stopcocks sealed by Viton O-rings at both ends. Pressure depletion in the flask during the O2/N2 measurement does not cause any detectable change in the O2/N2 ratio, but the O2/N2 ratio in the flask was found to gradually decrease during the storage period. We also present preliminary results from air samples collected at Hateruma Island (latitude 24°03'N, longitude 123°49') from July 1997 through March 1999. The observed O2/N2 ratios clearly show a seasonal variation, increasing in spring and summer and decreasing in autumn and winter.

  1. Gas-liquid chromatographic and gas-liquid-mass spectometric determination of fenvalerate and permethrin residues in grasshoppers and duck tissue samples

    USGS Publications Warehouse

    Reichel, W.L.; Kolbe, E.J.; Stafford, C.J.

    1981-01-01

    A procedure is described for determining fenvalerate and permethrin residues in grasshoppers and duck tissues. Samples are Soxhlet-extracted with hexane and cleaned up by gel permeation chromatography with an in-line alumina column. Samples are analyzed by gas-liquid chromatography with electron capture detection, and confirmed by gas-liquid chromatography-mass spectrometry. The average recovery from fortified tissues was 97%.

  2. Aerosol, Cloud and Trace Gas Observations Derived from Airborne Hyperspectral Radiance and Direct Beam Measurements in Recent Field Campaigns

    NASA Technical Reports Server (NTRS)

    Redemann, J.; Flynn, C. J.; Shinozuka, Y.; Kacenelenbogen, M.; Segal-Rosenheimer, M.; LeBlanc, S.; Russell, P. B.; Livingston, J. M.; Schmid, B.; Dunagan, S. E.; Johnson, R. R.

    2014-01-01

    The AERONET (AErosol RObotic NETwork) ground-based suite of sunphotometers provides measurements of spectral aerosol optical depth (AOD), precipitable water and spectral sky radiance, which can be inverted to retrieve aerosol microphysical properties that are critical to assessments of aerosol-climate interactions. Because of data quality criteria and sampling constraints, there are significant limitations to the temporal and spatial coverage of AERONET data and their representativeness for global aerosol conditions. The 4STAR (Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research) instrument, jointly developed by NASA Ames and PNNL with NASA Goddard collaboration, combines airborne sun tracking and AERONET-like sky scanning with spectroscopic detection. Being an airborne instrument, 4STAR has the potential to fill gaps in the AERONET data set. Dunagan et al. [2013] present results establishing the performance of the instrument, along with calibration, engineering flight test, and preliminary scientific field data. The 4STAR instrument operated successfully in the SEAC4RS [Studies of Emissions and Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys] experiment in Aug./Sep. 2013 aboard the NASA DC-8 and in the DoE [Department of Energy]-sponsored TCAP [Two Column Aerosol Project, July 2012 & Feb. 2013] experiment aboard the DoE G-1 aircraft (Shinozuka et al., 2013), and acquired a wealth of data in support of mission objectives on all SEAC4RS and TCAP research flights. 4STAR provided direct beam measurements of hyperspectral AOD, columnar trace gas retrievals (H2O, O3, NO2; Segal-Rosenheimer et al., 2014), and the first ever airborne hyperspectral sky radiance scans, which can be inverted to yield the same products as AERONET ground-based observations. In addition, 4STAR measured zenith radiances underneath cloud decks for retrievals of cloud optical depth and effective diameter. In this presentation, we provide an overview of the new

  3. Gas/particle partitioning behavior of perfluorocarboxylic acids with terrestrial aerosols.

    PubMed

    Arp, Hans Peter H; Goss, Kai-Uwe

    2009-11-15

    Experimentally determined gas/particle partitioning constants, K(ip), using inverse gas chromatography (IGC) are presented for perfluorocarboxylic acids (PFCAs), covering a diverse set of terrestrial aerosols over an ambient range of relative humidity (RH) and temperature. The results are compared to estimated K(ip) values using a recently developed model that has been validated for diverse neutral and ionizable organic compounds. The modeling results consistently underestimate the experimental results. This is likely due to additional partition mechanisms unique for surfactants not being accounted for in the model, namely aggregate formation and water surface adsorption. These processes likely also biased the IGC K(ip) measurements compared to ambient PFCA concentrations. Nevertheless, both the experimental and modeling results indicate that partitioning to terrestrial particles in ambient atmospheres is negligible, though sorption to condensed water can be substantial. This favors rain sequestration as a more important atmospheric removal mechanism than dry particle sequestration. PFCAs found on particle filters during ambient sampling are thus accountable to vapor-phase PFCAs or aqueous-phase PFCAs sorbing directly to the filters, or the trapping of perfluorocarboxylate-salt particles. Further work on understanding the partitioning and speciation of PFCAs in atmospheric water droplets is needed to further quantify and understand their atmospheric behavior. To aid in this, a general RH dependent K(ip) model for surfactants is presented.

  4. Modeling Gas-phase Glyoxal and Associated Secondary Organic Aerosol Formation in a Megacity using WRF/Chem

    NASA Astrophysics Data System (ADS)

    Wang, K.; Hodzic, A.; Barth, M. C.; Jimenez, J. L.; Volkamer, R.; Ervens, B.; Zhang, Y.

    2011-12-01

    Organic aerosol (OA) as one of a major fine particulate matter in the atmosphere plays an important role in air pollution, human health, and climate forcing. OA is composed of directly emitted primary organic aerosol and chemically produced secondary organic aerosols (SOA). Despite much recent progress in understanding SOA formation, current air quality models cannot explain the magnitude and growth of atmospheric SOA, due to high uncertainties in sources, properties, and chemical reactions of precursors and formation pathways of SOA. Recent laboratory and modeling studies showed that glyoxal may serve as an important SOA precursor in the condensed solution of inorganic or organic aerosol particles (e.g., ammonium sulfate, fulvic acid, and amino acids). In this study, the Weather Research and Forecasting model with chemistry (WRF/Chem) is modified to account for the latest observed gas-phase yields of glyoxal from various volatile organic compounds (VOCs) and the associated SOA formation in the aqueous aerosol phase. The SOA formation in the aqueous aerosol phase is implemented using two approaches. In the first approach, two simplified parameterizations are used to represent the lumped particle-phase chemical processes under dark conditions and photochemical surface uptake. In the second approach, more detailed kinetic glyoxal reactions such as reversible glyoxal uptake, dimer formation of glyoxal, and oligomerization are treated and resolved explicitly. The updated WRF/Chem is assessed over the Mexico City and the surrounding region during March 2006 using the MILAGRO campaign data. Various observations such as organic matter from Aerodyne Aerosol Mass Spectrometer and VOCs from Proton-transfer Ion Trap Mass Spectrometry were compared. The preliminary results showed that the addition of the SOA formation from glyoxal in aqueous particles brings SOA predictions into a better agreement with field observations, in particular in presence of high relative humidity

  5. THE EFFECT OF METASTABLE EQUILIBRIUM STATES ON THE PARTITIONING OF NITRATE BETWEEN THE GAS AND AEROSOL PHASES. (R826371C005)

    EPA Science Inventory

    With the aid of three atmospheric aerosol equilibrium models, we quantify the effect of metastable equilibrium states (efflorescence branch) in comparison to stable (deliquescence branch) on the partitioning of total nitrate between the gas and aerosol phases. On average, effl...

  6. Polymer-coated micro-optofluidic ring resonator detector for a comprehensive two-dimensional gas chromatographic microsystem: μGC ×μGC-μOFRR.

    PubMed

    Collin, William R; Scholten, Kee W; Fan, Xudong; Paul, Dibyadeep; Kurabayashi, Katsuo; Zellers, Edward T

    2016-01-01

    We describe first results from a micro-analytical subsystem that integrates a detector comprising a polymer-coated micro-optofluidic ring resonator (μOFRR) chip with a microfabricated separation module capable of performing thermally modulated comprehensive two-dimensional gas chromatographic separations (μGC ×μGC) of volatile organic compound (VOC) mixtures. The 2 × 2 cm μOFRR chip consists of a hollow, contoured SiO(x) cylinder (250 μm i.d.; 1.2 μm wall thickness) grown from a Si substrate, and integrated optical and fluidic interconnection features. By coupling to a 1550 nm tunable laser and photodetector via an optical fiber taper, whispering gallery mode (WGM) resonances were generated within the μOFRR wall, and shifts in the WGM wavelength caused by transient sorption of eluting vapors into the PDMS film lining the μOFRR cylinder were monitored. Isothermal separations of a simple alkane mixture using a PDMS coated 1st-dimension ((1)D) μcolumn and an OV-215-coated 2nd-dimension ((2)D) μcolumn confirmed that efficient μGC ×μGC-μOFRR analyses could be performed and that responses were dominated by film-swelling. Subsequent tests with more diverse VOC mixtures demonstrated that the modulated peak width and the VOC sensitivity were inversely proportional to the vapor pressure of the analyte. Modulated peaks as narrow as 120 ms and limits of detection in the low-ng range were achieved. Structured contour plots generated with the μOFRR and a reference FID were comparable. PMID:26588451

  7. Determination of odor release in hydrocolloid model systems containing original or carboxylated cellulose at different pH values using static headspace gas chromatographic (SHS-GC) analysis.

    PubMed

    Lee, Sang Mi; Shin, Gil-Ok; Park, Kyung Min; Chang, Pahn-Shick; Kim, Young-Suk

    2013-01-01

    Static headspace gas chromatographic (SHS-GC) analysis was performed to determine the release of 13 odorants in hydrocolloid model systems containing original or regio-selectively carboxylated cellulose at different pH values. The release of most odor compounds was decreased in the hydrocolloid solutions compared to control, with the amounts of 2-propanol, 3-methyl-1-butanol, and 2,3-butanedione released into the headspace being less than those of any other odor compound in the hydrocolloid model systems. However, there was no considerable difference between original cellulose-containing and carboxylated-cellulose containing systems in the release of most compounds, except for relatively long-chain esters such as ethyl caprylate and ethyl nonanoate. The release from the original and carboxylated cellulose solutions controlled to pH 10 was significantly higher than that from solutions adjusted to pH 4 and 7 in the case of some esters (ethyl acetate, methyl propionate, ethyl propionate, ethyl butyrate, butyl propionate, ethyl caproate) and alcohols (2-propanol, 3-methyl-1-butanol), in particular, ethyl butyrate and 3-methyl-1-butanol. In contrast, the release of 2,3-butanedione from both the original and carboxylated cellulose solutions was increased at pH 4 and 7 compared to that at pH 10 by about 70% and 130%, respectively. Our study demonstrated that the release of some odorants could be changed significantly by addition of both original and carboxylated cellulose in hydrocolloid model systems, but only minor effect was observed in pH of the solution. PMID:23447013

  8. Determination of Odor Release in Hydrocolloid Model Systems Containing Original or Carboxylated Cellulose at Different pH Values Using Static Headspace Gas Chromatographic (SHS-GC) Analysis

    PubMed Central

    Lee, Sang Mi; Shin, Gil-Ok; Park, Kyung Min; Chang, Pahn-Shick; Kim, Young-Suk

    2013-01-01

    Static headspace gas chromatographic (SHS-GC) analysis was performed to determine the release of 13 odorants in hydrocolloid model systems containing original or regio-selectively carboxylated cellulose at different pH values. The release of most odor compounds was decreased in the hydrocolloid solutions compared to control, with the amounts of 2-propanol, 3-methyl-1-butanol, and 2,3-butanedione released into the headspace being less than those of any other odor compound in the hydrocolloid model systems. However, there was no considerable difference between original cellulose-containing and carboxylated-cellulose containing systems in the release of most compounds, except for relatively long-chain esters such as ethyl caprylate and ethyl nonanoate. The release from the original and carboxylated cellulose solutions controlled to pH 10 was significantly higher than that from solutions adjusted to pH 4 and 7 in the case of some esters (ethyl acetate, methyl propionate, ethyl propionate, ethyl butyrate, butyl propionate, ethyl caproate) and alcohols (2-propanol, 3-methyl-1-butanol), in particular, ethyl butyrate and 3-methyl-1-butanol. In contrast, the release of 2,3-butanedione from both the original and carboxylated cellulose solutions was increased at pH 4 and 7 compared to that at pH 10 by about 70% and 130%, respectively. Our study demonstrated that the release of some odorants could be changed significantly by addition of both original and carboxylated cellulose in hydrocolloid model systems, but only minor effect was observed in pH of the solution. PMID:23447013

  9. Effect of cation-exchange pretreatment of aqueous soil extracts on the gas chromatographic-mass spectrometric determination of nerve agent hydrolysis products after tert.-butyldimethylsilylation.

    PubMed

    Kataoka, M; Tsunoda, N; Ohta, H; Tsuge, K; Takesako, H; Seto, Y

    1998-10-23

    The efficiency of pretreatment of aqueous soil extracts using a cation-exchange resin has been investigated by gas chromatographic-mass spectrometric (GC-MS) determination of nerve agent hydrolysis products after tert.-butyldimethylsilyl (TBDMS) derivatization. An aqueous solution containing methylphosphonic acid (MPA) and its monoalkyl esters, ethyl methylphosphonic acid, isopropyl methylphosphonic acid and pinacolyl methylphosphonic acid, was dried, and these phosphonic acids were derivatized with N-methyl-N-(tert.-butyldimethylsilyl)trifluoro-acetamide and analyzed by GC-MS. The yields of TBDMS derivatives were significantly decreased by the addition of calcium and magnesium ions to an aqueous solution (approximately 0.5 mM) before derivatization. The extent of lowered yields was related to the hydrophilicity of phosphonic acids. MPA and its monoalkyl esters were spiked into soil samples (sand, alluvial soil and volcanic ash soil), extracted with distilled water, dried, silylated and applied to GC-MS. The yields of TBDMS derivatives of monoalkyl esters from soil samples were low (3-42%) and MPA derivative was scarcely detected (yield: < 0.7%). By desalting the aqueous soil extract by passage through a strong cation-exchange resin, the yields of TBDMS derivatives of monoalkyl esters were significantly improved (12-69%) and MPA derivative was detected (yield: 2-36%). The extent of improved yields was related to the concentrations of divalent metal cations in aqueous soil extracts. In combination with desalting by the cation-exchange resin, GC-MS after TBDMS derivatization enables detection of nerve agent hydrolysis products in soils at sub-ppm (0.2 microgram/g) concentrations. PMID:9818434

  10. Comparing different gas chromatographic methods for the quantification of bisphenol A (BPA) trace levels in paper and cardboard products from the market.

    PubMed

    Jurek, A; Leitner, E

    2015-01-01

    Bisphenol A (BPA; 4,4'-(propane-2,2-diyl)diphenol), a suspected endocrine disruptor with weak estrogenic activity, is used in a variety of consumer products, including paper and cardboard products used as food contact materials. The present study compared four different gas chromatographic methods for the analysis of BPA in paper and cardboard food packages. Eighteen different food packages were extracted and BPA was determined using two different derivatisation reactions--trimethylsilylation with N,O-bis(trimethylsilyl) trifluoroacetamide (BSTFA) and halide alkylation with pentafluorobenzoyl chloride (PFBOCl)--and four different separation and detection techniques. The BSTFA derivatives were quantified with (1) GC-MS in single-ion monitoring (SIM) mode with electron ionisation (EI-GC-MS) and (2) GC-MS/MS in multiple reaction monitoring (MRM) mode using electron ionisation (EI-GC-MS/MS); while the PFBOCl derivatives were quantified with (3) GC-MS using electron ionisation (EI-GC-MS) as well as (4) GC-MS with negative chemical ionisation (NCI-GC-MS). All developed methods showed good linearity (R(2) > 0.9938), precision (CV < 4.5% for reproducibility; CV < 2.2% for repeatability) and sensitivity, with limits of detection (LODs) between 0.02 µg kg(-1) for the pentafluorobenzoyl derivatives measured with the NCI-GC-MS method and 6 µg kg(-1) for the pentafluorobenzoyl derivatives determined with EI-GC-MS. Levels of BPA in the samples were in agreement for all methods, ranging from values below the limit of quantitation (LOQ) to 11.9 mg kg(-1) paper. In a last step, the maximum potential migration into food products was calculated for all tested paper and cardboard samples, assuming a 'worst case' scenario of 100% migration.

  11. Polymer-coated micro-optofluidic ring resonator detector for a comprehensive two-dimensional gas chromatographic microsystem: μGC ×μGC-μOFRR.

    PubMed

    Collin, William R; Scholten, Kee W; Fan, Xudong; Paul, Dibyadeep; Kurabayashi, Katsuo; Zellers, Edward T

    2016-01-01

    We describe first results from a micro-analytical subsystem that integrates a detector comprising a polymer-coated micro-optofluidic ring resonator (μOFRR) chip with a microfabricated separation module capable of performing thermally modulated comprehensive two-dimensional gas chromatographic separations (μGC ×μGC) of volatile organic compound (VOC) mixtures. The 2 × 2 cm μOFRR chip consists of a hollow, contoured SiO(x) cylinder (250 μm i.d.; 1.2 μm wall thickness) grown from a Si substrate, and integrated optical and fluidic interconnection features. By coupling to a 1550 nm tunable laser and photodetector via an optical fiber taper, whispering gallery mode (WGM) resonances were generated within the μOFRR wall, and shifts in the WGM wavelength caused by transient sorption of eluting vapors into the PDMS film lining the μOFRR cylinder were monitored. Isothermal separations of a simple alkane mixture using a PDMS coated 1st-dimension ((1)D) μcolumn and an OV-215-coated 2nd-dimension ((2)D) μcolumn confirmed that efficient μGC ×μGC-μOFRR analyses could be performed and that responses were dominated by film-swelling. Subsequent tests with more diverse VOC mixtures demonstrated that the modulated peak width and the VOC sensitivity were inversely proportional to the vapor pressure of the analyte. Modulated peaks as narrow as 120 ms and limits of detection in the low-ng range were achieved. Structured contour plots generated with the μOFRR and a reference FID were comparable.

  12. Preparation and characterization of molecularly imprinted polymer for di(2-ethylhexyl) phthalate: application to sample clean-up prior to gas chromatographic determination.

    PubMed

    Shaikh, Huma; Memon, Najma; Khan, Hamayun; Bhanger, M I; Nizamani, S M

    2012-07-20

    The molecularly imprinted polymer (MIP) selective for di(2-ethylhexyl) phthalate (DEHP) an environmental endocrine disruptor was prepared by suspension polymerization using methacrylamide as functional monomer and N,N'-methylene-bis-acrylamide as cross-linker. The imprinted polymer was employed for solid-phase extraction of DEHP from water samples of environmental importance and characterized by FT-IR and SEM. The adsorption properties of the imprinted polymer were demonstrated by equilibrium rebinding experiments, Pseudo-second-order kinetic model, Sips isotherm and Scatchard analysis. The reusability of MIP was checked for at least six repeated batch adsorption cycles and the results showed almost no deterioration in the adsorption capacity. The competitive recognition studies were performed with DEHP and structurally similar compounds; dimethyl phthalate (DMP), diethyl phthalate (DEP), and dibutyl phthalate (DBP). The imprinting factor (IF) of DEHP was found to be 12.86 which was much higher than the imprinting factors (IF) of other phthalates. A method constituted by molecularly imprinted solid-phase extraction (MISPE) with GC-FID was developed for DEHP analysis in water samples under very simple conditions. Sample loading and desorption conditions were also optimized. The MISPE method's linearity ranged from 0.035 to 3.0 μg ml⁻¹ with r² = 0.9998. Intra-assay, interassay precision and accuracy ranged from 0.0168% to 1.017%, 1.130% to 4.799% and 94.98% to 99.35%, respectively. The LOD and LOQ were found to be 0.011 and 0.035 μg ml⁻¹, respectively. Synthesized MIP was employed in MISPE for cleaning up the spiked river water samples prior to gas chromatographic analysis. The river samples were found to contain DEHP in the range of 1.4 × 10⁻³ to 0.349 μg ml⁻¹. PMID:22673816

  13. Novel methods for predicting gas-particle partitioning during the formation of secondary organic aerosol

    NASA Astrophysics Data System (ADS)

    Wania, F.; Lei, Y. D.; Wang, C.; Abbatt, J. P. D.; Goss, K.-U.

    2014-12-01

    Several methods have been presented in the literature to predict an organic chemical's equilibrium partitioning between the water insoluble organic matter (WIOM) component of aerosol and the gas phase, Ki,WIOM, as a function of temperature. They include (i) polyparameter linear free energy relationships calibrated with empirical aerosol sorption data, as well as (ii) the solvation models implemented in SPARC and (iii) the quantum-chemical software COSMOtherm, which predict solvation equilibria from molecular structure alone. We demonstrate that these methods can be used to predict Ki,WIOM for large numbers of individual molecules implicated in secondary organic aerosol (SOA) formation, including those with multiple functional groups. Although very different in their theoretical foundations, these methods give remarkably consistent results for the products of the reaction of normal alkanes with OH, i.e. their partition coefficients Ki,WIOM generally agree within one order of magnitude over a range of more than ten orders of magnitude. This level of agreement is much better than that achieved by different vapour pressure estimation methods that are more commonly used in the SOA community. Also, in contrast to the agreement between vapour pressure estimates, the agreement between the Ki,WIOM estimates does not deteriorate with increasing number of functional groups. Furthermore, these partitioning coefficients Ki,WIOM predicted SOA mass yields in agreement with those measured in chamber experiments of the oxidation of normal alkanes. If a Ki,WIOM prediction method was based on one or more surrogate molecules representing the solvation properties of the mixed OM phase of SOA, the choice of those molecule(s) was found to have a relatively minor effect on the predicted Ki,WIOM, as long as the molecule(s) are not very polar. This suggests that a single surrogate molecule, such as 1-octanol or a hypothetical SOA structure proposed by Kalberer et al. (2004), may often be

  14. Ozone Observations by the Gas and Aerosol Measurement Sensor during SOLVE II

    NASA Technical Reports Server (NTRS)

    Pitts, M. C.; Thomason, L. W.; Zawodny, J. M.; Wenny, B. N.; Livingston, J. M.; Russell, P. B.; Yee, J.-H.; Swartz, W. H.; Shetter, R. E.

    2006-01-01

    The Gas and Aerosol Measurement Sensor (GAMS) was deployed aboard the NASA DC-8 aircraft during the second SAGE III Ozone Loss and Validation Experiment (SOLVE II). GAMS acquired line-of-sight (LOS) direct solar irradiance spectra during the sunlit portions of ten science flights of the DC-8 between 12 January and 4 February 2003. Differential line-of-sight (DLOS) optical depth spectra are produced from the GAMS raw solar irradiance spectra. Then, DLOS ozone number densities are retrieved from the GAMS spectra using a multiple linear regression spectral fitting technique. Both the DLOS optical depth spectra and retrieved ozone data are compared with coincident measurements from two other solar instruments aboard the DC-8 platform to demonstrate the robustness and stability of the GAMS data. The GAMS ozone measurements are then utilized to evaluate the quality of the Wulf band ozone cross sections, a critical component of the SAGE III aerosol, water vapor, and temperature/pressure retrievals. Results suggest the ozone cross section compilation of Shettle and Anderson currently used operationally in SAGE III data processing may be in error by as much as 10-20% in theWulf bands, and their lack of reported temperature dependence is a significant deficiency. A second, more recent, cross section database compiled for the SCIAMACHY satellite mission appears to be of much better quality in the Wulf bands, but still may have errors as large as 5% near the Wulf band absorption peaks, which is slightly larger than their stated uncertainty. Additional laboratory measurements of the Wulf band cross sections should be pursued to further reduce their uncertainty and better quantify their temperature dependence.

  15. Evaluation of anthropogenic influence on thermodynamics, gas and aerosol composition of city air

    NASA Astrophysics Data System (ADS)

    Uzhegova, Nina; Belan, Boris; Antokhin, Pavel; Zhidovkhin, Evgenii; Ivlev, Georgii; Kozlov, Artem; Fofonov, Aleksandr

    2010-05-01

    In the last 40-50 years there is a global tendency of urbanisation, which is a consequence of most countries' economical development. Concurrently, the issue of environment's ecological state has become critical. Urban air pollution is among the most important ecological problems nowadays. World Health Organization (WHO) points out certain "classical" polluting agents: carbon monoxide (CO), nitric oxide (NO), nitrogen dioxide (NO2), sulphur dioxide (SO2), troposphere ozone (O3) (studied here), as well as lead, carbon dioxide (CO2), aldehydes, soot, benzpyrene and dredges (including dust, haze and smoke) [1]. An evaluation of antropogenic component's weight in the thermodynamical conditions and gas and aerosol composition of a city's atmosphere (by the example of Tomsk) is given in this paper. Tomsk is located at the South of West Siberia and is the administrative center of Tomsk region. The city's area is equal to 294,6 km2. Its population is 512.6 thousands of people. The overall number of registered motor vehicles in the city in 2008 was 131 700. That is, every fourth city inhabitant has a personal car. From 2002 to 2008 the number of motor vehicles in Tomsk has increased by 25 thousands units [2]. This increase consists mostly of passenger cars. There is also a positive trend in fuel consumtion by the city's industries and motor vehicles - from 2004 to 2007 it has increased by 10%. Such a quick rate of transport quantity's increase in the city provides reason to suggest an unfavorable ecological situation in Tomsk. For this study we have used the AKV-2 mobile station designed by the SB RAS Institute of Atmospheric Optics. The station's equipment provides the following measurements [3]: air temperature and humidity; aerosol disperse composition in 15 channels with a particle size range of 0.3-20 µm by use of the Grimm-1.108 aerosol spectrometer; NO, NO2, O3, SO2, CO, CO2 concentration. This paper describes a single experiment conducted in Tomsk. Date of

  16. Measurement of Gas and Aerosol Phase Absorption Spectra across the Visible and Near-IR Using Supercontinuum Photoacoustic Spectroscopy.

    PubMed

    Radney, James G; Zangmeister, Christopher D

    2015-07-21

    We demonstrate a method to measure the absorption spectra of gas and aerosol species across the visible and near-IR (500 to 840 nm) using a photoacoustic (PA) spectrometer and a pulsed supercontinuum laser source. Measurements of gas phase absorption spectra were demonstrated using H2O(g) as a function of relative humidity (RH). The measured absorption intensities and peak shapes were able to be quantified and compared to spectra calculated using the 2012 High Resolution Transmission (HITRAN2012) database. Size and mass selected nigrosin aerosol was used to measure absorption spectra across the visible and near-IR. Spectra were measured as a function of aerosol size/mass and show good agreement to Mie theory calculations. Lastly, we measured the broadband absorption spectrum of flame generated soot aerosol at 5% and 70% RH. For the high RH case, we are able to quantifiably separate the soot and water absorption contributions. For soot, we observe an enhancement in the mass specific absorption cross section ranging from 1.5 at 500 nm (p < 0.01) to 1.2 at 840 nm (p < 0.2) and a concomitant increase in the absorption Ångström exponent from 1.2 ± 0.4 (5% RH) to 1.6 ± 0.3 (70% RH). PMID:26098142

  17. Improved solid aerosol generator

    DOEpatents

    Prescott, D.S.; Schober, R.K.; Beller, J.

    1988-07-19

    An improved solid aerosol generator used to produce a gas borne stream of dry, solid particles of predetermined size and concentration. The improved solid aerosol generator nebulizes a feed solution of known concentration with a flow of preheated gas and dries the resultant wet heated aerosol in a grounded, conical heating chamber, achieving high recovery and flow rates. 2 figs.

  18. Solid aerosol generator

    DOEpatents

    Prescott, Donald S.; Schober, Robert K.; Beller, John

    1992-01-01

    An improved solid aerosol generator used to produce a gas borne stream of dry, solid particles of predetermined size and concentration. The improved solid aerosol generator nebulizes a feed solution of known concentration with a flow of preheated gas and dries the resultant wet heated aerosol in a grounded, conical heating chamber, achieving high recovery and flow rates.

  19. Solid aerosol generator

    DOEpatents

    Prescott, D.S.; Schober, R.K.; Beller, J.

    1992-03-17

    An improved solid aerosol generator used to produce a gas borne stream of dry, solid particles of predetermined size and concentration is disclosed. The improved solid aerosol generator nebulizes a feed solution of known concentration with a flow of preheated gas and dries the resultant wet heated aerosol in a grounded, conical heating chamber, achieving high recovery and flow rates. 2 figs.

  20. Improvement and further development in CESM/CAM5: gas-phase chemistry and inorganic aerosol treatments

    NASA Astrophysics Data System (ADS)

    He, J.; Zhang, Y.

    2014-09-01

    Gas-phase chemistry and subsequent gas-to-particle conversion processes such as new particle formation, condensation, and thermodynamic partitioning have large impacts on air quality, climate, and public health through influencing the amounts and distributions of gaseous precursors and secondary aerosols. Their roles in global air quality and climate are examined in this work using the Community Earth System Model version 1.0.5 (CESM1.0.5) with the Community Atmosphere Model version 5.1 (CAM5.1) (referred to as CESM1.0.5/CAM5.1). CAM5.1 includes a simple chemistry that is coupled with a 7-mode prognostic Modal Aerosol Model (MAM7). MAM7 includes classical homogenous nucleation (binary and ternary) and activation nucleation (empirical first-order power law) parameterizations, and a highly simplified inorganic aerosol thermodynamics treatment that only simulates particulate-phase sulfate and ammonium. In this work, a new gas-phase chemistry mechanism based on the 2005 Carbon Bond Mechanism for Global Extension (CB05_GE) and several advanced inorganic aerosol treatments for condensation of volatile species, ion-mediated nucleation (IMN), and explicit inorganic aerosol thermodynamics for sulfate, ammonium, nitrate, sodium, and chloride have been incorporated into CESM/CAM5.1-MAM7. Compared to the simple gas-phase chemistry, CB05_GE can predict many more gaseous species, and thus could improve model performance for PM2.5, PM10, PM components, and some PM gaseous precursors such as SO2 and NH3 in several regions as well as aerosol optical depth (AOD) and cloud properties (e.g., cloud fraction (CF), cloud droplet number concentration (CDNC), and shortwave cloud forcing, SWCF) on the global scale. The modified condensation and aqueous-phase chemistry could further improve the prediction of additional variables such as HNO3, NO2, and O3 in some regions, and new particle formation rate (J) and AOD on the global scale. IMN can improve the prediction of secondary PM2

  1. Inference of the aerosol Angstrom coefficient from SAGE short-wavelength data. [Stratospheric Aerosol and Gas Experiment

    NASA Technical Reports Server (NTRS)

    Lenoble, J.; Pruvost, P.

    1983-01-01

    SAGE four-channel transmission profiles are inverted to retrieve the extinction profiles from which the aerosol Angstrom coefficient alpha is obtained. The procedure allows one to check the influence of the NO2 absorption profile, which is small below 25 km. The results compare well with those obtained by a completely different procedure at NASA Langley Research Center, and the main features of the alpha profiles seem to be significant, even considering the rather large error bars. The relation between the retrieved Angstrom coefficient, the particle effective radius and the asymmetry factor is considered.

  2. Authentication of geographical origin of palm oil by chromatographic fingerprinting of triacylglycerols and partial least square-discriminant analysis.

    PubMed

    Ruiz-Samblás, Cristina; Arrebola-Pascual, Cristina; Tres, Alba; van Ruth, Saskia; Cuadros-Rodríguez, Luis

    2013-11-15

    Main goals of the present work were to develop authentication models based on liquid and gas chromatographic fingerprinting of triacylglycerols (TAGs) from palm oil of different geographical origins in order to compare them. For this purpose, a set of palm oil samples were collected from different continents: South eastern Asia, Africa and South America. For the analysis of the information in these fingerprint profiles, a pattern recognition technique such as partial least square discriminant analysis (PLS-DA) was applied to discriminate the geographical origin of these oils, at continent level. The liquid chromatography, coupled to a charged aerosol detector, (HPLC-CAD) TAGs separation was optimized in terms of mobile phase composition and by means of a solid silica core column. The gas chromatographic method with a mass spectrometer was applied under high temperature (HTGC-MS) in order to analyze the intact TAGs. Satisfactory chromatographic resolution within a short total analysis time was achieved with both chromatographic approaches and without any prior sample treatment. The rates of successful in prediction of the geographical origin of the 85 samples varied between 70% and 100%. PMID:24148475

  3. Improvement and further development in CESM/CAM5: gas-phase chemistry and inorganic aerosol treatments

    NASA Astrophysics Data System (ADS)

    He, J.; Zhang, Y.

    2013-10-01

    Gas-phase chemistry and subsequent gas-to-particle conversion processes such as new particle formation, condensation, and thermodynamic partitioning have large impacts on air quality, climate, and public health through influencing the amounts and distributions of gaseous precursors and secondary aerosols. Their roles in global air quality and climate are examined in this work using the Community Earth System Model version 1.0.5 (CESM1.0.5) with the Community Atmosphere Model version 5.1 (CAM5.1) (referred to as CESM1.0.5/CAM5.1). CAM5.1 includes a simple chemistry that is coupled with a 7-mode prognostic Modal Aerosol Model (MAM7). MAM7 includes classical homogenous nucleation (binary and ternary) and activation nucleation (empirical first-order power law) parameterizations, and a highly-simplified inorganic aerosol thermodynamics treatment that only simulates sulfate (SO42-) and ammonium (NH4+). In this work, a new gas-phase chemistry mechanism based on the 2005 Carbon Bond Mechanism for Global Extension (CB05_GE) and several advanced inorganic aerosol treatments for condensation of volatile species, ion-mediated nucleation (IMN), and explicit inorganic aerosol thermodynamics have been incorporated into CESM/CAM5.1-MAM7. Comparing to the simple gas-phase chemistry, CB05_GE can predict many more gaseous species, and improve model performance for PM2.5, PM10, PM2.5 components, and some PM gaseous precursors such as SO2 and NH3 in several regions, as well as aerosol optical depth (AOD) and cloud properties (e.g., cloud fraction (CF), cloud droplet number concentration (CDNC), and shortwave cloud forcing (SWCF)) on globe. The modified condensation and aqueous-phase chemistry further improves the predictions of additional variables such as HNO3, NO2, and O3 in some regions, and new particle formation rate (J) and AOD over globe. IMN can improve the predictions of secondary PM2.5 components, PM2.5, and PM10 over Europe, as well as AOD and CDNC over globe. The explicit

  4. Aerosol and trace gas vehicle emission factors measured in a tunnel using an Aerosol Mass Spectrometer and other on-line instrumentation

    NASA Astrophysics Data System (ADS)

    Chirico, Roberto; Prevot, Andre S. H.; DeCarlo, Peter F.; Heringa, Maarten F.; Richter, Rene; Weingartner, Ernest; Baltensperger, Urs

    2011-04-01

    In this study we present measurements of gas and aerosol phase composition for a mixed vehicle fleet in the Gubrist tunnel (Switzerland) in June 2008. PM 1 composition measurements were made with a High-Resolution Time-of-Flight Aerosol Mass Spectrometer (AMS) and a Multi Angle Absorption Photometer (MAAP). Gas-phase measurements of CO, CO 2, NO x and total hydrocarbons (THC) were performed with standard instrumentation. Weekdays had a characteristic diurnal pattern with 2 peaks in concentrations for all traffic related species corresponding to high vehicle density (˜300 ± 30 vehicles per 5 min) in the morning rush hour between 06:00 and 09:00 and in the afternoon rush hours from approximately 15:30 to 18:30. The emission factors (EF) of OA were heavily influenced by the OA mass loading. To exclude this partitioning effect, only organic aerosol mass concentrations from 60 μg m -3 to 90 μg m -3 were considered and for these conditions the EF(OA) value for HDV was 33.7 ± 2.3 mg km -1 for a temperature inside the tunnel of 20-25 °C. This value is not directly applicable to ambient conditions because it is derived from OA mass concentrations that are roughly a factor of 10 higher than typical ambient concentrations. An even higher EF(OA) HDV value of 47.4 ± 1.6 mg km -1 was obtained when the linear fit was applied to all data points including OA concentrations up to 120 μg m -3. Similar to the increasing EF, the OA/BC ratio in the tunnel was also affected by the organic loading and it increased by a factor of ˜3 over the OA range 10-120 μg m -3. This means that also the OA emission factors at ambient concentrations of around 5-10 μg m -3 would be 2-3 times lower than the emission factor given above. For OA concentrations lower than 40 μg m -3 the OA/BC mass ratio was below 1, while at an OA concentration of 100-120 μg m -3 the OA/BC ratio was ˜1.5. The AMS mass spectra (MS) acquired in the tunnel were highly correlated with the primary organic aerosol

  5. Sudden changes in aerosol and gas concentrations in the central Arctic marine boundary layer: Causes and consequences

    NASA Astrophysics Data System (ADS)

    Bigg, E. Keith; Leck, Caroline; Nilsson, E. Douglas

    2001-12-01

    Measurements of aerosol number size distributions and concentrations of the precursor gases dimethyl sulfide, sulfur dioxide and ammonia were made within the pack ice region of the central Arctic Ocean during July and August 1996 from the icebreaker Oden. Changes in concentration, sometimes exceeding the entire seasonal variation, often occurred within an hour and attempts to find the reasons for them are described. Vertical profiles of aerosol concentration in Aitken and accumulation mode particles obtained on helicopter flights revealed intense concentration gradients in the lowest 1000 m. Those below 100 m were common. Concentrations of accumulation mode particles were usually greater near the surface than at 100 m. Four representative case studies for which vertical aerosol profiles were obtained are presented. Observations of rapid large changes in near-surface concentration of aerosols in different size ranges are compared with the vertical profiles, meteorological information, and acoustic or optical remote sensing to infer processes causing the changes. Comparison of simultaneous variations in aerosols and precursor gas concentrations are used to define the vertical profiles of the gases. It was found that dimethyl sulfide and ammonia concentrations usually must have been strongly depleted near the surface relative to concentrations at about 100 m. Sulfur dioxide profiles appeared to be more complex. Turbulence or vertical air motions initiated by atmospheric wave motions trapped within the stable boundary layer appeared to be directly responsible for many of the sudden concentration changes, through interaction with concentration gradients close to the surface. The presence of low-level jets also had direct or indirect influences on mixing in the lowest few hundred meters. The extent to which aerosols measured near the surface can determine the microphysics of central Arctic marine boundary layer clouds is examined.

  6. Airborne Trace Gas and Aerosol Measurements in Several Shale Gas Basins during the SONGNEX (Shale Oil and Natural Gas Nexus) Campaign 2015

    NASA Astrophysics Data System (ADS)

    Warneke, C.; Trainer, M.; De Gouw, J. A.

    2015-12-01

    Oil and natural gas from tight sand and shale formations has increased strongly over the last decade. This increased production has been associated with emissions of methane, non-methane hydrocarbons and other trace gases to the atmosphere, which are concerns for air quality, climate and air toxics. The NOAA Shale Oil and Natural Gas Nexus (SONGNEX) aircraft campaign took place in 2015, when the NOAA WP-3 aircraft conducted 20 research flights between March 19 and April 27, 2015 in the following shale gas regions: Denver-Julesberg, Uintah, Upper Green River, San Juan, Bakken, Barnett, Eagle Ford, Haynesville, Woodford, and Permian. The NOAA P3 was equipped with an extensive set of gas phase measurements, including instruments for methane, ethane, CO, CO2, a new H3O+CIMS, canister and cartridge samples for VOCs, HCHO, glyoxal, HNO3, NH3, NOx, NOy, PANs, ozone, and SO2. Aerosol number and size distributions were also measured. This presentation will focus on an overview of all the measurements onboard the NOAA WP-3 aircraft and discuss the differences between the shale gas regions. Due to a drop in oil prices, drilling for oil decreased in the months prior to the mission, but nevertheless the production of oil and natural gas were near the all-time high. Many of the shale gas basins investigated during SONGNEX have quite different characteristics. For example, the Permian Basin is a well-established field, whereas the Eagle Ford and the Bakken saw an almost exponential increase in production over the last few years. The basins differ by the relative amounts of natural gas versus oil that is being produced. Previous work had shown a large variability in methane emissions relative to the production (leak rate) between different basins. By including more and qualitatively different basins during SONGNEX, the study has provided an extensive data set to address how emissions depend on raw gas composition, extraction techniques and regulation. The influence of these

  7. Bulk, surface, and gas-phase limited water transport in aerosol.

    PubMed

    Davies, James F; Haddrell, Allen E; Miles, Rachael E H; Bull, Craig R; Reid, Jonathan P

    2012-11-15

    The influence of solute species on mass transfer to and from aqueous aerosol droplets is investigated using an electrodynamic balance coupled with light scattering techniques. In particular, we explore the limitations imposed on water evaporation by slow bulk phase diffusion and by the formation of surface organic films. Measurements of evaporation from ionic salt solutions, specifically sodium chloride and ammonium sulfate, are compared with predictions from an analytical model framework, highlighting the uncertainties associated with quantifying gas diffusional transport. The influence of low solubility organic acids on mass transfer is reported and compared to both model predictions and previous work. The limiting value of the evaporation coefficient that can be resolved by this approach, when uncertainties in key thermophysical quantities are accounted for, is estimated. The limitation of slow bulk phase diffusion on the evaporation rate is investigated for gel and glass states formed during the evaporation of magnesium sulfate and sucrose droplets, respectively. Finally, the effect of surfactants on evaporation has been probed, with soluble surfactants (such as sodium dodecyl sulfate) leading to little or no retardation of evaporation through slowing of surface layer kinetics. PMID:23095147

  8. Simulating gas and aerosol concentrations in the Paris area using different land surface models

    NASA Astrophysics Data System (ADS)

    Khvorostyanov, Dmitry; Menut, Laurent; Dupont, Jean-Charles; Morille, Yoann; Haeffelin, Martial

    2010-05-01

    Regional air quality forecasting depends on the performance of weather forecast models used to drive chemistry-transport models. The widely used Weather Research and Forecasting (WRF) model provides a few land surface schemes (LSMs) to compute heat and moisture fluxes over land surface. The LSMs differ in complexity and approaches used. We performed WRF simulations for 15 and 5 km resolution nested domains over the North of France and Paris, respectively, for summer 2008. We used the four LSMs provided with WRF: 6-layer Rapid Update Cycle (RUC), 5-layer thermal diffusion, 2-layer Pleim-Xiu scheme (together with the Pleim-Xiu surface layer and the ACM boundary layer models), and 4-layer Noah scheme. The SIRTA atmospheric observatory located in Paris area provides in situ data of measurements for a number of meteorological parameters, as well as vertical profiles measured by a lidar. The simulation results were compared to the SIRTA measurement data. In order to quantify possible impacts of the LSMs to simulated gas and aerosol concentrations in the Paris region, we use a chemistry-transport model CHIMERE forced by the corresponding WRF meteorological fields. Implications for the regional air quality forecasting will be discussed.

  9. Stratospheric ozone variations in the equatorial region as seen in Stratiospheric Aerosol and Gas Experiment data

    SciTech Connect

    Shiotani, M.; Hasebe, F. |

    1994-07-01

    An analysis is made of equatorial ozone variations for 5 years, 1984-1989, using the ozone profile data derived from the Stratospheric Aerosol and Gas Experiment II (SAGE II) instrument. Attention is focused on the annual cycle and also on interannual variability, particularly the quasi-biennial oscillation (QBO) and El Nino-Southern Oscillation (ENSO) variations in the lower stratosphere, where the largest contribution to total column ozone takes place. The annual variation in zonal mean total ozone around the equator is composed of symmetric and asymmetric modes with respect to the equator, with maximum contributions being around 19 km for the symmetric mode and around 25 km for the asymmetric mode. The persistent zonal wavenumber 1 structure observed by the total ozone mapping spectrometer over the equator is almost missing in the SAGE-derived column amounts integrated in the stratosphere, suggesting a significant contribution from tropospheric ozone. Interannual variations in the equatorial ozone are dominated by the QBO above 20 km and the ENSO-related variation below 20 km. The ozone QBO is characterized by zonally uniform phase changes in association with the zonal wind QBO in the equatorial lower stratosphere. The ENSO-related ozone variation consists of both the east-west vacillation and the zonally uniform phase variation. During the El Nino event, the east-west contrast with positive (negative) deviations in the eastern (western) hemisphere is conspicuous, while the decreasing tendency of the zonal mean values is maximum at the same time.

  10. Stratospheric ozone variations in the equatorial region as seen in Stratiospheric Aerosol and Gas Experiment data

    NASA Technical Reports Server (NTRS)

    Shiotani, Masato; Hasebe, Fumio

    1994-01-01

    An analysis is made of equatorial ozone variations for 5 years, 1984-1989, using the ozone profile data derived from the Stratospheric Aerosol and Gas Experiment II (SAGE II) instrument. Attention is focused on the annual cycle and also on interannual variability, particularly the quasi-biennial oscillation (QBO) and El Nino-Southern Oscillation (ENSO) variations in the lower stratosphere, where the largest contribution to total column ozone takes place. The annual variation in zonal mean total ozone around the equator is composed of symmetric and asymmetric modes with respect to the equator, with maximum contributions being around 19 km for the symmetric mode and around 25 km for the asymmetric mode. The persistent zonal wavenumber 1 structure observed by the total ozone mapping spectrometer over the equator is almost missing in the SAGE-derived column amounts integrated in the stratosphere, suggesting a significant contribution from tropospheric ozone. Interannual variations in the equatorial ozone are dominated by the QBO above 20 km and the ENSO-related variation below 20 km. The ozone QBO is characterized by zonally uniform phase changes in association with the zonal wind QBO in the equatorial lower stratosphere. The ENSO-related ozone variation consists of both the east-west vacillation and the zonally uniform phase variation. During the El Nino event, the east-west contrast with positive (negative) deviations in the eastern (western) hemisphere is conspicuous, while the decreasing tendency of the zonal mean values is maximum at the same time.

  11. Near-highway aerosol and gas-phase measurements in a high-diesel environment

    NASA Astrophysics Data System (ADS)

    DeWitt, H. L.; Hellebust, S.; Temime-Roussel, B.; Ravier, S.; Polo, L.; Jacob, V.; Buisson, C.; Charron, A.; André, M.; Pasquier, A.; Besombes, J. L.; Jaffrezo, J. L.; Wortham, H.; Marchand, N.

    2015-04-01

    Diesel-powered passenger cars currently outnumber gasoline-powered cars in many countries, particularly in Europe. In France, diesel cars represented 61% of light duty vehicles in 2011 and this percentage is still increasing (French Environment and Energy Management Agency, ADEME). As part of the September 2011 joint PM-DRIVE (Particulate Matter - DiRect and Indirect on-road Vehicular Emissions) and MOCOPO (Measuring and mOdeling traffic COngestion and POllution) field campaign, the concentration and high-resolution chemical composition of aerosols and volatile organic carbon species were measured adjacent to a major urban highway south of Grenoble, France. Alongside these atmospheric measurements, detailed traffic data were collected from nearby traffic cameras and loop detectors, which allowed the vehicle type, traffic concentration, and traffic speed to be quantified. Six aerosol age and source profiles were resolved using the positive matrix factorization model on real-time high-resolution aerosol mass spectra. These six aerosol source/age categories included a hydrocarbon-like organic aerosol (HOA) commonly associated with primary vehicular emissions, a nitrogen-containing aerosol with a diurnal pattern similar to that of HOA, oxidized organic aerosol (OOA), and biomass burning aerosol. While quantitatively separating the influence of diesel from that of gasoline proved impossible, a low HOA : black carbon ratio, similar to that measured in other high-diesel environments, and high levels of NOx, also indicative of diesel emissions, were observed. Although the measurement site was located next to a large source of primary emissions, which are typically found to have low oxygen incorporation, OOA was found to comprise the majority of the measured organic aerosol, and isotopic analysis showed that the measured OOA contained mainly modern carbon, not fossil-derived carbon. Thus, even in this heavily vehicular-emission-impacted environment, photochemical processes

  12. Acquisition of a Gas Chromatograph/Mass Spectrometer System for Laboratory Study of Prebiotic Organic Geochemical Processes on the Early Earth, Mars, and Meteorites

    NASA Technical Reports Server (NTRS)

    McCollom, Thomas

    2004-01-01

    This was a major equipment grant that provided funds ($72K) for purchase of a benchtop gas chromatograph-mass spectrometer (GC-MS) for use in experimental studies of prebiotic organic compounds. An Agilent model 689015973 GC-MS was purchased and installed in the PI's lab in August of 2003. The instrument is now being used for a variety of research projects. The primary use of the instrument is to analyze and quantify organic products of laboratory experiments conducted by the PI. One example is shown, which shows organic products (predominantly n-alkanes) formed during Fischer-Tropsch-type abiotic synthesis under hydrothermal conditions. The analytical capabilities of the GC- MS allowed identification of the numerous organic products of this as well as other laboratory experiments. A key use of the instrument in this research is that the mass spectrometer capabilities allow use of isotopically labeled reactants to trace the progress of reactions and evaluate background contaminants. collaborative projects with other scientists involved in exobiology & astrobiology research (e.g., Mitch Schulte, NASA Ames; Katrina Edwards, Woods Hole Oceanographic Institution). For instance, an analysis of membrane lipids of an lithoautotrophic iron-oxidizing bacteria being grown on basalt as a source of metabolic energy, a project where the instrument is being used to evaluate possible biomarker compounds from these organisms is shown. These iron oxidizers are thought to be similar to those living within the ocean crust, and are being investigated as possible analog organisms to those on the early Earth or crust of Mars. The instrument has also been used by an outside investigator (graduate student Brandon Canfeld, Arizona State University) for identification and isotopic characterization of experimental products of abiotic organic synthesis experiments he is conducting with Dr. John Holloway. analysis of quality control samples for other NASA-funded projects. For instance, an

  13. Search for organic molecules on Mars with the Gas Chromatograph-Mass Spectrometer of the Sample Analysis at Mars experiment onboard the MSL 2011 Curiosity rover

    NASA Astrophysics Data System (ADS)

    Szopa, C.; Francois, P.; Coll, P. J.; Cabane, M.; Coscia, D.; Teinturier, S.; Stalport, F.; Buch, A.; Mahaffy, P. R.; Glavin, D. P.; Freissinet, C.; Eigenbrode, J. L.

    2012-12-01

    In past times, life might have emerged under Martian conditions milder than the present ones, and left some remnants at the surface. Even if this did not happen, prebiotic molecules may have been preserved in the soil, and they might be similar to those that prevailed on the Earth surface some 3.5 to 4 billion years ago. NASA's MSL2011 rover Curiosity will explore the surface and subsurface of Mars, seeking traces of prebiotic or biological activity. Organic signatures are among the main signatures of interest in this frame, and they will be among the main targets of the Gas Chromatograph Quadrupole Mass Spectrometer (GC-QMS) which constitutes the core of the Sample Analysis at Mars (SAM) analytical laboratory, developed by the NASA/GSFC in collaboration with the University of Paris (Fr) and the JPL. The main goal of this instrumentation is indeed to determine molecular abundances and isotopic ratios of organic molecules present in the collected samples, by analyzing gases either sampled from the atmosphere, or obtained from soil processing, either by physical heating or chemical reactions. In order to prepare for the interpretation of the data obtained in situ with the GCQMS of SAM, and due to the complexity of this instrumentation, a number of calibrations are required to determine the exact behaviour of each part of this instrumentation, that is required to correctly treat the signal and obtain a correct interpretation of it. In order to prepare the SAM-GC in situ results treatment and interpretation, it is necessary: (1) to determine the instrument ability to detect targets molecules under the instrument operating conditions and (2) to create data bases to help for the identification and quantification of the molecules that could be detected with SAM. With this aim we first selected molecules which might be analyzed with SAM-GC using the following criteria: (1) abundance at the Mars surface (2) astrobiological interest, (3) formation during the sample

  14. Modelling non-equilibrium secondary organic aerosol formation and evaporation with the aerosol dynamics, gas- and particle-phase chemistry kinetic multi-layer model ADCHAM

    NASA Astrophysics Data System (ADS)

    Roldin, P.; Eriksson, A. C.; Nordin, E. Z.; Hermansson, E.; Mogensen, D.; Rusanen, A.; Boy, M.; Swietlicki, E.; Svenningsson, B.; Zelenyuk, A.; Pagels, J.

    2014-01-01

    We have developed the novel Aerosol Dynamics, gas- and particle-phase chemistry model for laboratory CHAMber studies (ADCHAM). The model combines the detailed gas phase Master Chemical Mechanism version 3.2, an aerosol dynamics and particle phase chemistry module (which considers acid catalysed oligomerization, heterogeneous oxidation reactions in the particle phase and non-ideal interactions between organic compounds, water and inorganic ions) and a kinetic multilayer module for diffusion limited transport of compounds between the gas phase, particle surface and particle bulk phase. In this article we describe and use ADCHAM to study: (1) the mass transfer limited uptake of ammonia (NH3) and formation of organic salts between ammonium (NH4+) and carboxylic acids (RCOOH), (2) the slow and almost particle size independent evaporation of α-pinene secondary organic aerosol (SOA) particles, and (3) the influence of chamber wall effects on the observed SOA formation in smog chambers. ADCHAM is able to capture the observed α-pinene SOA mass increase in the presence of NH3(g). Organic salts of ammonium and carboxylic acids predominantly form during the early stage of SOA formation. These salts contribute substantially to the initial growth of the homogeneously nucleated particles. The model simulations of evaporating α-pinene SOA particles support the recent experimental findings that these particles have a semi-solid tar like amorphous phase state. ADCHAM is able to reproduce the main features of the observed slow evaporation rates if low-volatility and viscous oligomerized SOA material accumulates in the particle surface layer upon evaporation. The evaporation rate is mainly governed by the reversible decomposition of oligomers back to monomers. Finally, we demonstrate that the mass transfer limited uptake of condensable organic compounds onto wall deposited particles or directly onto the Teflon chamber walls of smog chambers can have profound influence on the

  15. Top-down constraints to aerosol emissions from open biomass burning: the role of gas-particle partitioning and secondary organic aerosol formation

    NASA Astrophysics Data System (ADS)

    Konovalov, Igor B.; Beekmann, Matthias; Berezin, Evgeny V.; Petetin, Hervé

    2014-05-01

    Open biomass burning (BB), including wildfires and controlled burns in agriculture and foresty, is known to provide an important contribution to organic aerosol (OA) and black carbon (BC) emissions on the global scale. However, quantitative estimates of BB aerosol emissions and their effects on climate and environment remain rather uncertain. A useful way to constrain the OA&BC emissions involves using atmospheric measurements in the framework of the inverse modeling approach. In such an approach, the relationship between the emissions and the measurements is simulated by a chemistry transport model; this means that top-down estimates may be sensitive to possible model uncertainties. As a result of assimilation of satellite measurements of aerosol optical depth, several recent studies (e.g. [1,2]) indicated that aerosol emissions provided by bottom-up emission inventories may be strongly underestimated relative to emissions of gaseous species (such as CO). Meanwhile, it was earlier shown (e.g. [3]) that the relationship between primary organic aerosol emissions and aerosol concentration in the atmosphere can be significantly affected by gas-particle partitioning and oxidation of lower-volatility organic emissions; these processes are usually not taken into account in typical chemistry transport models. The main goal of this study was to examine to what degree the discrepancy between the OA&BC/CO emission ratios predicted by the bottom-up inventories and derived from satellite observations can be associated with the mentioned processes and explained in the framework of the volatility basis set approach (VBS) [3] to OA modelling. To achieve this goal, a VBS scheme, which was recently implemented in the CHIMERE chemistry transport model (CTM), was first modified to account for OA emissions from biomass burning. An ensemble of simulations with the CHIMERE CTM was then performed for the case of the 2010 mega-fire event in European Russia [4]; each of the simulations

  16. Aerosol and gas re-distribution by shallow cumulus clouds: An investigation using airborne measurements

    NASA Astrophysics Data System (ADS)

    Wonaschuetz, Anna; Sorooshian, Armin; Ervens, Barbara; Chuang, Patrick Y.; Feingold, Graham; Murphy, Shane M.; de Gouw, Joost; Warneke, Carsten; Jonsson, Haflidi H.

    2012-09-01

    Aircraft measurements during the 2006 Gulf of Mexico Atmospheric Composition and Climate Study (GoMACCS) are used to examine the influence of shallow cumulus clouds on vertical profiles of aerosol chemical composition, size distributions, and secondary aerosol precursor gases. The data show signatures of convective transport of particles, gases and moisture from near the surface to higher altitudes, and of aqueous-phase production of aerosol mass (sulfate and organics) in cloud droplets and aerosol water. In cloudy conditions, the average aerosol volume concentration at an altitude of 2850 m, above typical cloud top levels, was found to be 34% of that at 450 m; for clear conditions, the same ratio was 13%. Both organic and sulfate mass fractions were on average constant with altitude (around 50%); however, the ratio of oxalate to organic mass increased with altitude (from 1% at 450 m to almost 9% at 3450 m), indicative of the influence of in-cloud production on the vertical abundance and characteristics of secondary organic aerosol (SOA) mass. A new metric termed "residual cloud fraction" is introduced as a way of quantifying the "cloud processing history" of an air parcel. Results of a parcel model simulating aqueous phase production of sulfate and organics reproduce observed trends and point at a potentially important role of SOA production, especially oligomers, in deliquesced aerosols. The observations emphasize the importance of shallow cumulus clouds in altering the vertical distribution of aerosol properties that influence both their direct and indirect effect on climate.

  17. Evaluation of Meso-NH and WRF/CHEM simulated gas and aerosol chemistry over Europe based on hourly observations

    NASA Astrophysics Data System (ADS)

    Berger, A.; Barbet, C.; Leriche, M.; Deguillaume, L.; Mari, C.; Chaumerliac, N.; Bègue, N.; Tulet, P.; Gazen, D.; Escobar, J.

    2016-07-01

    Gas chemistry and aerosol chemistry of 10 km-resolution mesoscale models Meso-NH and WRF/CHEM were evaluated on three cases over Europe. These one-day duration cases were selected from Freney et al. (2011) and occurred on contrasted meteorological conditions and at different seasons: a cyclonic circulation with a well-marked frontal zone on winter, an anti-cyclonic situation with local storm precipitations on summer and a cold front in the northwest of Europe associated to a convergence of air masses over eastern Europe and conflicting air masses over Spain and France on autumn. To assess the performance of the two models, surface hourly databases from observation stations over Europe were used, together with airborne measurements. For both models, the meteorological fields were in good agreement with the measurements for the three days. Winds presented the largest normalised mean bias integrated over all European stations for both models. Daily gas chemistry was reproduced with normalised mean biases between - 14 and 11%, a level of accuracy that is acceptable for policy support. The two models' performances were degraded during night-time quite likely due to the constant primary species emissions. The PM2.5 bulk mass concentration was overestimated by Meso-NH over Europe and slightly underestimated by WRF/CHEM. The absence of wet deposition in the models partly explains the local discrepancies with the observations. More locally, the systematic low mixing ratio of volatile organic compounds in the gas phase simulated by WRF/CHEM at three stations was correlated with the underestimation of OM (organic matter) mass in the aerosol phase. Moreover, this mass of OM was mainly composed of anthropogenic POAs (primary organic aerosols) in WRF/CHEM, suggesting a missing source for SOAs (secondary organic aerosols) mass in WRF/CHEM aerosol parameterisation. The contribution of OM was well simulated by Meso-NH, with a higher contribution for the summer case. For Meso

  18. Comparison of stratospheric aerosol and gas experiment I (SAGE I) and Umkehr ozone profiles including a search for Umkehr aerosol effects

    SciTech Connect

    Newchurch, M.J.

    1986-01-01

    After briefly reviewing ozone depletion predictions from atmospheric models and results from trend analysis of Umkehr data, this paper outlines the Umkehr method for deducing the vertical profile of ozone and reviews the theoretical and empirical studies of the aerosol effect on Umkehr measurements. A brief description of the Stratospheric Aerosol and Gas Experiment I (SAGE I) is followed by a method for approximating the best representation of the conditions over the Umkehr ground site as seen by the SAGE I satellite. Using a spatially weighted average of SAGE I events derived from an autocorrelation analysis, the authors find 337 co-located SAGE I and Umkehr events. The approximate total column ozone measured by SAGE I is 5% higher than that measured by Umkehr on average. Most of this difference resides in Umkehr layer two, three, and four, while layers seven, eight, and nine contain small differences in average ozone content. Intercomparison with four other ozone studies indicates agreement between SAGE I and SBUV in most layers and at most Umkehr stations north of 30/sup 0/. However, significant differences in Umkehr layer eight between SAGE I and SBUV remain. Ozone differences between SAGE I and Umkehr are strong functions of both total column ozone and season in the lower layers but not in the upper layers.

  19. "Virtual injector" flow tube method for measuring relative rates kinetics of gas-phase and aerosol species.

    PubMed

    Renbaum-Wolff, Lindsay; Smith, Geoffrey D

    2012-06-28

    A new method for measuring gas-phase and aerosol reaction kinetics is described in which the gas flow, itself, acts as a "virtual injector" continuously increasing the contact time in analogy to conventional movable-injector kinetics techniques. In this method a laser is directed down the length of a flow tube, instantly initiating reaction by photodissociation of a precursor species at every point throughout the flow tube. Key tropospheric reactants such as OH, Cl, NO(3), and O(3) can be generated with nearly uniform concentrations along the length of the flow tube in this manner using 355 nm radiation from the third harmonic of a Nd:YAG laser. As the flow travels down the flow tube, both the gas-phase and particle-phase species react with the photogenerated radicals or O(3) for increasingly longer time before exiting and being detected. The advantages of this method are that (1) any wall loss of gas-phase and particle species is automatically accounted for, (2) the reactions are conducted under nearly pseudo-first-order conditions, (3) the progress of the reaction is followed as a continuous function of reaction time instead of reactant concentration, (4) data collection is quick with an entire decay trace being collected in as little as 1 min, (5) relative rates of several species can be measured simultaneously, and (6) bimolecular rate constants at least as small as k = 10(-17) (cm(3)/molecule)/s, or aerosol uptake coefficients at least as small as γ = 10(-4), can be measured. Using the virtual injector technique with an aerosol chemical ionization mass spectrometer (CIMS) as a detector, examples of gas-phase relative rates and uptake by oleic acid particles are given for OH, Cl, NO(3), and O(3) reactions with most agreeing to within 20% of published values, where available.

  20. Air pollution from gas flaring: new emission factor estimates and detection in a West African aerosol remote-sensing climatology

    NASA Astrophysics Data System (ADS)

    MacKenzie, Rob; Fawole, Olusegun Gabriel; Levine, James; Cai, Xiaoming

    2016-04-01

    Gas flaring, the disposal of gas through stacks in an open-air flame, is a common feature in the processing of crude oil, especially in oil-rich regions of the world. Gas flaring is a prominent source of volatile organic compounds (VOCs), polycyclic aromatic hydrocarbons (PAH), CO, CO2, nitrogen oxides (NOx), SO2 (in "sour" gas only), and soot (black carbon), as well as the release of locally significant amounts of heat. The rates of emission of these pollutants from gas flaring depend on a number of factors including, but not limited to, fuel composition and quantity, stack geometry, flame/combustion characteristics, and prevailing meteorological conditions. Here, we derive new estimated emission factors (EFs) for carbon-containing pollutants (excluding PAH). The air pollution dispersion model, ADMS5, is used to simulate the dispersion of the pollutants from flaring stacks in the Niger delta. A seasonal variation of the dispersion pattern of the pollutant within a year is studied in relation to the movements of the West Africa Monsoon (WAM) and other prevailing meteorological factors. Further, we have clustered AERONET aerosol signals using trajectory analysis to identify dominant aerosol sources at the Ilorin site in West Africa (4.34 oE, 8.32 oN). A 10-year trajectory-based analysis was undertaken (2005-2015, excluding 2010). Of particular interest are air masses that have passed through the gas flaring region in the Niger Delta area en-route the AERONET site. 7-day back trajectories were calculated using the UK Universities Global Atmospheric Modelling Programme (UGAMP) trajectory model which is driven by analyses from the European Centre for Medium-Range Weather Forecasts (ECMWF). From the back-trajectory calculations, dominant sources are identified, using literature classifications: desert dust (DD); Biomass burning (BB); and Urban-Industrial (UI). We use a combination of synoptic trajectories and aerosol optical properties to distinguish a fourth source

  1. Constraining the volatility distribution and gas-particle partitioning of combustion aerosols using isothermal dilution and thermodenuder measurements.

    PubMed

    Grieshop, Andrew P; Miracolo, Marissa A; Donahue, Niel M; Robinson, Allen L

    2009-07-01

    The gas-particle partitioning of primary organic aerosol (POA) emissions from a diesel engine and the combustion of hard- and soft-woods in a stove was investigated by isothermally diluting them in a smog chamber or by passing them through a thermodenuder and measuring the extent of evaporation. The experiments were conducted at atmospherically relevant conditions: low concentrations and small temperature perturbations. The partitioning of the POA emissions from both sources varied continuously with changing concentration and temperature. Although the POA emissions are semivolatile, they do not completely evaporate at typical atmospheric conditions. The overall partitioning characteristics of diesel and wood smoke POA are similar, with wood smoke being somewhat less volatile than the diesel exhaust. The gas-particle partitioning of aerosols formed from flash-vaporized engine lubricating oil was also studied; diesel POA is somewhat more volatile than the oil aerosol. The experimental data from the dilution- and thermodenuder-based techniques were fit using absorptive partitioning theory to derive a volatility distribution of the POA emissions from each source. These distributions are suitable for use in chemical transport models that simulate POA concentrations.

  2. Top-down constraints to aerosol emissions from open biomass burning: the role of gas-particle partitioning and secondary organic aerosol formation

    NASA Astrophysics Data System (ADS)

    Konovalov, Igor B.; Beekmann, Matthias; Berezin, Evgeny V.; Petetin, Hervé

    2014-05-01

    Open biomass burning (BB), including wildfires and controlled burns in agriculture and foresty, is known to provide an important contribution to organic aerosol (OA) and black carbon (BC) emissions on the global scale. However, quantitative estimates of BB aerosol emissions and their effects on climate and environment remain rather uncertain. A useful way to constrain the OA&BC emissions involves using atmospheric measurements in the framework of the inverse modeling approach. In such an approach, the relationship between the emissions and the measurements is simulated by a chemistry transport model; this means that top-down estimates may be sensitive to possible model uncertainties. As a result of assimilation of satellite measurements of aerosol optical depth, several recent studies (e.g. [1,2]) indicated that aerosol emissions provided by bottom-up emission inventories may be strongly underestimated relative to emissions of gaseous species (such as CO). Meanwhile, it was earlier shown (e.g. [3]) that the relationship between primary organic aerosol emissions and aerosol concentration in the atmosphere can be significantly affected by gas-particle partitioning and oxidation of lower-volatility organic emissions; these processes are usually not taken into account in typical chemistry transport models. The main goal of this study was to examine to what degree the discrepancy between the OA&BC/CO emission ratios predicted by the bottom-up inventories and derived from satellite observations can be associated with the mentioned processes and explained in the framework of the volatility basis set approach (VBS) [3] to OA modelling. To achieve this goal, a VBS scheme, which was recently implemented in the CHIMERE chemistry transport model (CTM), was first modified to account for OA emissions from biomass burning. An ensemble of simulations with the CHIMERE CTM was then performed for the case of the 2010 mega-fire event in European Russia [4]; each of the simulations

  3. Liquid chromatographic extraction medium

    DOEpatents

    Horwitz, E. Philip; Dietz, Mark L.

    1994-01-01

    A method and apparatus for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column is described. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water.

  4. Liquid chromatographic extraction medium

    DOEpatents

    Horwitz, E.P.; Dietz, M.L.

    1994-09-13

    A method and apparatus are disclosed for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water. 1 fig.

  5. Seasonal variations in Titan's stratosphere observed with Cassini/CIRS: temperature, trace molecular gas and aerosol mixing ratio profiles

    NASA Astrophysics Data System (ADS)

    Vinatier, S.; Bézard, B.; Anderson, C.; Teanby, N.; Lebonnois, S.; Rannou, P.; de Kok, R.; T. CIRS Team

    2013-09-01

    Titan's northern spring equinox occurred in August 2009. General Circulation Models (e.g. [1]) predict strong modifications of the global circulation in this period, with formation of two circulation cells instead of the pole-to-pole cell that occurred during northern winter. This winter single cell, which had its descending branch at the north pole, was at the origin of the enrichment of molecular abundances and high stratopause temperatures observed by Cassini/CIRS at high northern latitudes (e.g., [2], [3], [4], [5]). The predicted dynamical seasonal variations after the equinox have strong impact on the spatial distributions of trace gas, temperature and aerosol abundances. We will present here an analysis of CIRS limbgeometry datasets acquired in 2010, 2011 and 2012 that we used to monitor the seasonal evolution of the vertical profiles of temperature, molecular (C2H2, C2H6, HCN, ...) and aerosol abundances.

  6. Greenhouse gas aerosols and pollutants over Siberia: the YAK-AEROSIB French Russian Joint International Laboratory

    NASA Astrophysics Data System (ADS)

    Paris, Jean-Daniel; Belan, Boris D.; Ancellet, Gérard; Nédélec, Philippe; Arshinov, Mikhail Yu.; Pruvost, Arnaud; Berchet, Antoine; Arzoumanian, Emmanuel; Pison, Isabelle; Ciais, Philippe; Law, Kathy

    2014-05-01

    Despite the unique scientific value of better knowing atmospheric composition over Siberia, regional observations of the tropospheric composition over this region are still lacking. Large local anthropogenic emissions, strong ecosystem gas exchange across the vast forest expanse, and processes feeding back to global climate such as wetlands CH4 emissions, seabed hydrates destabilization and degrading permafrost make this region particularly crucial to investigate. We aim at addressing this need in the YAK-AEROSIB program by collecting high-precision in-situ measurements of the vertical distribution of CO2, CH4, CO, O3, black carbon and ultrafine particles distribution in the Siberian troposphere, as well as other parameters including aerosol lidar profiles, on a pan-Siberian aircraft transect. Campaigns are performed almost annually since 2006 until now on this regular route, while special campaigns are occasionnally arranged to sample the troposphere elsewere (e.g. Russian Arctic coast). We show the background tropospheric composition obtained from these surveys, the variability and the impact of large-scale transport of anthropogenic emissions from Europe and Asia, as well as the impact of biomass burning plumes both from local wildfires (2012) and from remote sources elsewhere in Asia. Long range transport of anthropogenic emissions is shown to have a discernible impact on O3 distribution, although its lower-tropospheric variability is largely driven by surface deposition. Regional sources and sinks drive the lower troposphere CO2 and CH4 concentrations. Recent efforts aim at better understanding the respective role of CH4 emission processes (including methanogenesis in wetlands and emissions by wildfires) in driving its large scale atmospheric variability over the region. Generally, the YAK AEROSIB provide unique observations over Siberia, documenting both direct impact of regional sources and aged air masses experiencing long range transport toward the high

  7. A comparison of the Stratospheric Aerosol and Gas Experiment II tropospheric water vapor to radiosonde measurements

    SciTech Connect

    Larsen, J.C.; Chiou, E.W. ); Chu, W.P.; McCormick, M.P.; McMaster, L.R. ); Oltmans, S. ); Rind, D. )

    1993-03-20

    Upper tropospheric Stratospheric Aerosol and Gas Experiment II (SAGE II) water vapor observations are compared to correlative radiosonde observations and radiosonde based climatologies. The SAGE II 1987 monthly zonal mean water vapor climatology is compared to both the Global Atmospheric Circulation Statistics (1963-1973) climatology and to the 1987 radiosonde climatology. The clear sky SAGE II climatology is found to be approximately half the level of both the clear/cloudy sky radiosonde climatologies. To determine whether this is realistic for these two different climatologies or includes additional observational and instrumental biases, the authors took the 1987 radiosonde data set and identified approximately 800 correlative profile pairs. The observational biases inherent to SAGE II and the radiosondes produce a set of profile pairs characteristic of clear sky, land conditions. A critical review of the radiosonde measurement capability was carried out to establish the operating range and accuracy in the upper troposphere. The authors show that even with tight coincidence criterion, the quality of the profile pair comparisons varies considerably because of strong water vapor variability occurring on small time and space scales. Annual zonal means calculated from the set of profile pairs again finds SAGE II significantly drier in many latitude bands. Resolving the radiosonde data base by hygrometer type shows this to be true for all hygrometers except for the thin film capacitive type (Vaisala Humicap). For this hygrometer, between 4.5 and 6.5 km SAGE II is drier by approximately 25.%, and from 8.5 to 11.5 km they are nearly equivalent when global annual means are compared. The good agreement with the Vaisala Humicap, currently the most accurate and responsive hygrometer in operational use, suggests existing radiosonde climatologies contain a significant moist bias in the upper troposphere. 31 refs., 16 figs., 6 tabs.

  8. Aerosol lidar observations of atmospheric mixing in Los Angeles: Climatology and implications for greenhouse gas observations

    NASA Astrophysics Data System (ADS)

    Ware, John; Kort, Eric A.; DeCola, Phil; Duren, Riley

    2016-08-01

    Atmospheric observations of greenhouse gases provide essential information on sources and sinks of these key atmospheric constituents. To quantify fluxes from atmospheric observations, representation of transport—especially vertical mixing—is a necessity and often a source of error. We report on remotely sensed profiles of vertical aerosol distribution taken over a 2 year period in Pasadena, California. Using an automated analysis system, we estimate daytime mixing layer depth, achieving high confidence in the afternoon maximum on 51% of days with profiles from a Sigma Space Mini Micropulse LiDAR (MiniMPL) and on 36% of days with a Vaisala CL51 ceilometer. We note that considering ceilometer data on a logarithmic scale, a standard method, introduces, an offset in mixing height retrievals. The mean afternoon maximum mixing height is 770 m Above Ground Level in summer and 670 m in winter, with significant day-to-day variance (within season σ = 220m≈30%). Taking advantage of the MiniMPL's portability, we demonstrate the feasibility of measuring the detailed horizontal structure of the mixing layer by automobile. We compare our observations to planetary boundary layer (PBL) heights from sonde launches, North American regional reanalysis (NARR), and a custom Weather Research and Forecasting (WRF) model developed for greenhouse gas (GHG) monitoring in Los Angeles. NARR and WRF PBL heights at Pasadena are both systematically higher than measured, NARR by 2.5 times; these biases will cause proportional errors in GHG flux estimates using modeled transport. We discuss how sustained lidar observations can be used to reduce flux inversion error by selecting suitable analysis periods, calibrating models, or characterizing bias for correction in post processing.

  9. A Theoretical Study on Gas-Phase Coating of Aerosol Particles

    PubMed

    Jain; Fotou; Kodas

    1997-01-01

    In situ coating of aerosol particles by gas-phase and surface reaction in a flow reactor is modeled accounting for scavenging (capture of small particles by large particles) and simultaneous surface reaction along with the finite sintering rate of the scavenged particles. A log-normal size distribution is assumed for the host and coating particles to describe coagulation and a monodisperse size distribution is used for the coating particles to describe sintering. As an example, coating of titania particles with silica in a continuous flow hot-wall reactor was modeled. High temperatures, low reactant concentrations, and large host particle surface areas favored smoother coatings in the parameter range: temperature 1700-1800 K, host particle number concentration 1 x 10(5)-1 x 10(7) #/cm3, average host particle size 1 &mgr;m, inlet coating reactant concentration (SiCl4) 2 x 10(-7)-2 x 10(-10) mol/cm3, and various surface reaction rates. The fraction of silica deposited on the TiO2 particles decreased by more than seven times with a hundredfold increase in SiCl4 inlet concentration because of the resulted increase in the average SiO2 particle size under the assumed coating conditions. Increasing the TiO2 particle number concentration resulted in higher scavenging efficiency of SiO2. In the TiO2/SiO2 system it is likely that surface reaction as well as scavenging play important roles in the coating process. The results agree qualitatively with experimental observations of TiO2 particles coated in situ with silica.

  10. Ion mobility spectrometry-mass spectrometry (IMS-MS) for on- and offline analysis of atmospheric gas and aerosol species

    NASA Astrophysics Data System (ADS)

    Krechmer, Jordan E.; Groessl, Michael; Zhang, Xuan; Junninen, Heikki; Massoli, Paola; Lambe, Andrew T.; Kimmel, Joel R.; Cubison, Michael J.; Graf, Stephan; Lin, Ying-Hsuan; Budisulistiorini, Sri H.; Zhang, Haofei; Surratt, Jason D.; Knochenmuss, Richard; Jayne, John T.; Worsnop, Douglas R.; Jimenez, Jose-Luis; Canagaratna, Manjula R.

    2016-07-01

    Measurement techniques that provide molecular-level information are needed to elucidate the multiphase processes that produce secondary organic aerosol (SOA) species in the atmosphere. Here we demonstrate the application of ion mobility spectrometry-mass spectrometry (IMS-MS) to the simultaneous characterization of the elemental composition and molecular structures of organic species in the gas and particulate phases. Molecular ions of gas-phase organic species are measured online with IMS-MS after ionization with a custom-built nitrate chemical ionization (CI) source. This CI-IMS-MS technique is used to obtain time-resolved measurements (5 min) of highly oxidized organic molecules during the 2013 Southern Oxidant and Aerosol Study (SOAS) ambient field campaign in the forested SE US. The ambient IMS-MS signals are consistent with laboratory IMS-MS spectra obtained from single-component carboxylic acids and multicomponent mixtures of isoprene and monoterpene oxidation products. Mass-mobility correlations in the 2-D IMS-MS space provide a means of identifying ions with similar molecular structures within complex mass spectra and are used to separate and identify monoterpene oxidation products in the ambient data that are produced from different chemical pathways. Water-soluble organic carbon (WSOC) constituents of fine aerosol particles that are not resolvable with standard analytical separation methods, such as liquid chromatography (LC), are shown to be separable with IMS-MS coupled to an electrospray ionization (ESI) source. The capability to use ion mobility to differentiate between isomers is demonstrated for organosulfates derived from the reactive uptake of isomers of isoprene epoxydiols (IEPOX) onto wet acidic sulfate aerosol. Controlled fragmentation of precursor ions by collisionally induced dissociation (CID) in the transfer region between the IMS and the MS is used to validate MS peak assignments, elucidate structures of oligomers, and confirm the

  11. Ion mobility spectrometry–mass spectrometry (IMS–MS) for on- and offline analysis of atmospheric gas and aerosol species

    DOE PAGES

    Krechmer, Jordan E.; Groessl, Michael; Zhang, Xuan; Junninen, Heikki; Massoli, Paola; Lambe, Andrew T.; Kimmel, Joel R.; Cubison, Michael J.; Graf, Stephan; Lin, Ying-Hsuan; et al

    2016-07-25

    Measurement techniques that provide molecular-level information are needed to elucidate the multiphase processes that produce secondary organic aerosol (SOA) species in the atmosphere. Here we demonstrate the application of ion mobility spectrometry-mass spectrometry (IMS–MS) to the simultaneous characterization of the elemental composition and molecular structures of organic species in the gas and particulate phases. Molecular ions of gas-phase organic species are measured online with IMS–MS after ionization with a custom-built nitrate chemical ionization (CI) source. This CI–IMS–MS technique is used to obtain time-resolved measurements (5 min) of highly oxidized organic molecules during the 2013 Southern Oxidant and Aerosol Study (SOAS) ambientmore » field campaign in the forested SE US. The ambient IMS–MS signals are consistent with laboratory IMS–MS spectra obtained from single-component carboxylic acids and multicomponent mixtures of isoprene and monoterpene oxidation products. Mass-mobility correlations in the 2-D IMS–MS space provide a means of identifying ions with similar molecular structures within complex mass spectra and are used to separate and identify monoterpene oxidation products in the ambient data that are produced from different chemical pathways. Water-soluble organic carbon (WSOC) constituents of fine aerosol particles that are not resolvable with standard analytical separation methods, such as liquid chromatography (LC), are shown to be separable with IMS–MS coupled to an electrospray ionization (ESI) source. The capability to use ion mobility to differentiate between isomers is demonstrated for organosulfates derived from the reactive uptake of isomers of isoprene epoxydiols (IEPOX) onto wet acidic sulfate aerosol. Controlled fragmentation of precursor ions by collisionally induced dissociation (CID) in the transfer region between the IMS and the MS is used to validate MS peak assignments, elucidate structures of

  12. Gas-particle partitioning of organic acids during the Southern Oxidant and Aerosol Study (SOAS): measurements and modeling

    NASA Astrophysics Data System (ADS)

    Thompson, S.; Yatavelli, R.; Stark, H.; Kimmel, J.; Krechmer, J.; Day, D. A.; Isaacman, G. A.; Goldstein, A. H.; Khan, M. A. H.; Holzinger, R.; Lopez-Hilfiker, F.; Mohr, C.; Thornton, J. A.; Jayne, J. T.; Worsnop, D. R.; Jimenez, J. L.

    2014-12-01

    Gas-Particle partitioning measurements of organic acids were carried out during the Southern Oxidant and Aerosol Study (SOAS, June-July 2013) at the Centerville, AL Supersite in the Southeast US, a region with significant isoprene and terpene emissions. Organic acid measurements were made with a Chemical Ionization High Resolution Time-of-Flight Mass Spectrometer (HRToF-CIMS) with a Filter Inlet for Gases and AEROsols (FIGAERO) and acetate (CH3COO-) as the reagent ion. We investigate both individual species and bulk organic acids and partitioning to organic and water phases in the aerosol. Measured partitioning is compared to data from three other instruments that can also quantify gas-particle partitioning with high time resolution: another HRToF-CIMS using iodide (I-) as the reagent ion to ionize acids and other highly oxidized compounds, a Semivolatile Thermal Desorption Aerosol GC/MS (SV-TAG), and a Thermal Desorption Proton Transfer Time-of-Flight Mass Spectrometer (TD-PTRMS The partitioning measurements for three of the instruments are generally consistent, with results in the same range for most species and following similar temporal trends and diurnal cycles. The TD-PTRMS measures on average ½ the partitioning to the particle phase of the acetate CIMS. Both the measurements and the model of partitioning to the organic phase respond quickly to temperature, and the model agrees with the measured partitioning within the error of the measurement for multiple compounds, although many compounds do not match the modeled partitioning, especially at lower m/z. This discrepancy may be due to thermal decomposition of larger molecules into smaller ones when heated.

  13. Field detection of bacillus spore aerosols with stand-alone pyrolysis-gas chromatography and ion mobility spectrometry

    NASA Astrophysics Data System (ADS)

    Snyder, A.; Maswadeh, Waleed M.; Parsons, John A.; Tripathi, Ashish; Meuzelaar, Henk L. C.; Dworzanski, Jacek P.; Kim, Man-Goo

    1999-12-01

    A commercially available, hand-held chemical vapor detector was modified to detect Gram-positive Bacillus subtilis var. globigii spores (BG) in outdoor field scenarios. An Airborne Vapor Monitor (AVM) ion mobility spectrometry (IMS) vapor detector was interfaced to a biological sample processing and transfer introduction system. The biological sample processing was accomplished by quartz tube pyrolysis (Py), and the resultant vapor was transferred by gas chromatography (GC) to the IMS detector. The Py-GC/IMS system can be described as a hyphenated device where two analytical dimensions, in series, allow the separation and isolation of individual components from the pyrolytic decomposition of biological analytes. Gram positive spores such as BG contain 5 - 15% by weight of dipicolinic acid (DPA), and picolinic acid is a pyrolysis product of DPA. Picolinic acid has a high proton affinity, and it is detected in a sensitive fashion by the atmospheric pressure-based IMS device. Picolinic acid occupies a unique region in the GC/IMS data domain with respect to other bacterial pyrolysis products. A 1000 to 1, air-to-air, aerosol concentrator was interfaced to the Py-GC/IMS instrument, and the system was placed in an open-air, Western United States desert environment. The system was tested with BG spore aerosol releases, and the instrument was remotely operated during a trial. A Met-One aerosol particle counter was placed next to the Py-GC/IMS so as to obtain a real-time record of the ambient and bacterial aerosol challenges. The presence/absence of an aerosol event, determined by an aerosol particle counter and a slit sampler-agar plate system, was compared to the presence/absence of a picolinic acid response in a GC/IMS data window at selected times in a trial with respect to a BG challenge. In the 21 BG trials, the Py-GC/IMS instrument experienced two true negatives, no false positives, and the instrument developed a software failure in one trial. The remaining 18 trials

  14. The Stratospheric Aerosol and Gas Experiment III/International Space Station Mission: Science Objectives and Mission Status

    NASA Astrophysics Data System (ADS)

    Eckman, R.; Zawodny, J. M.; Cisewski, M. S.; Flittner, D. E.; McCormick, M. P.; Gasbarre, J. F.; Damadeo, R. P.; Hill, C. A.

    2015-12-01

    The Stratospheric Aerosol and Gas Experiment III/International Space Station (SAGE III/ISS) is a strategic climate continuity mission which was included in NASA's 2010 plan, "Responding to the Challenge of Climate and Environmental Change: NASA's Plan for a Climate-Centric Architecture for Earth Observations and Applications from Space." SAGE III/ISS continues the long-term, global measurements of trace gases and aerosols begun in 1979 by SAGE I and continued by SAGE II and SAGE III on Meteor 3M. Using a well characterized occultation technique, the SAGE III instrument's spectrometer will measure vertical profiles of ozone, aerosols, water vapor, nitrogen dioxide, and other trace gases relevant to ozone chemistry. The mission will launch in 2016 aboard a Falcon 9 spacecraft.The primary objective of SAGE III/ISS is to monitor the vertical distribution of aerosols, ozone, and other trace gases in the Earth's stratosphere and troposphere to enhance our understanding of ozone recovery and climate change processes in the stratosphere and upper troposphere. SAGE III/ISS will provide data necessary to assess the state of the recovery in the distribution of ozone, extend the SAGE III aerosol measurement record that is needed by both climate models and ozone models, and gain further insight into key processes contributing to ozone and aerosol variability. The multi-decadal SAGE ozone and aerosol data sets have undergone intense community scrutiny for accuracy and stability. SAGE ozone data have been used to monitor the effectiveness of the Montreal Protocol.The ISS inclined orbit of 51.6 degrees is ideal for SAGE III measurements because the orbit permits solar occultation measurement coverage to approximately +/- 70 degrees of latitude. SAGE III/ISS will make measurements using the solar occultation measurement technique, lunar occultation measurement technique, and the limb scattering measurement technique. In this presentation, we describe the SAGE III/ISS mission, its

  15. Response of North Pacific eastern subtropical mode water to greenhouse gas versus aerosol forcing

    NASA Astrophysics Data System (ADS)

    Li, Xiang; Luo, Yiyong

    2016-04-01

    Mode water is a distinct water mass characterized by a near vertical homogeneous layer or low potential vorticity, and is considered essential for understanding ocean climate variability. Based on the output of GFDL CM3, this study investigates the response of eastern subtropical mode water (ESTMW) in the North Pacific to two different single forcings: greenhouse gases (GHGs) and aerosol. Under GHG forcing, ESTMW is produced on lighter isopycnal surfaces and is decreased in volume. Under aerosol forcing, in sharp contrast, it is produced on denser isopycnal surfaces and is increased in volume. The main reason for the opposite response is because surface ocean-to-atmosphere latent heat flux change over the ESTMW formation region shoals the mixed layer and thus weakens the lateral induction under GHG forcing, but deepens the mixed layer and thus strengthens the lateral induction under aerosol forcing. In addition, local wind changes are also favorable to the opposite response of ESTMW production to GHG versus aerosol.

  16. An electrostatic precipitator for preparative gas-liquid chromatography.

    PubMed

    Borka, L; Privett, O S

    1966-03-01

    The effect of the operating variables of electrostatic precipitators on the recovery and structure of methyl esters and related aerosol forming compounds collected in preparative gas-liquid chromatography was studied.Aerosol formation was prevented by AC or DC voltages of 5000 to 12000 volts. AC was more effective than DC but caused changes in structure which were detectable by both thin-layer and gas-liquid chromatographic methods of analysis.An apparatus of simple construction and operation was designed for the collection of methyl esters and its use demonstrated with several model compounds.

  17. A Comprehensive Archive of Aerosol and Trace Gas Spatial Distributions for Model and Satellite Validation

    NASA Astrophysics Data System (ADS)

    Wilson, J. C.; Meland, B. S.; Axisa, D.

    2015-12-01

    The University of Denver Aerosol Group has assembled measured aerosol size distributions, gaseous concentrations, and atmospheric state variables covering a 30 year time period into one comprehensive archive. Measurements were made during the period 1987-2013 and include data from a total of 21 NASA field campaigns. Measurements were taken from the ground to over 21 km in altitude, from 72 S Latitude to 90 N latitude on over 300 individual flights on NASA Research Aircraft. Aerosol measurements were made with the University of Denver's Nucleation-Mode Aerosol Size Spectrometer (NMASS), Focused Cavity Aerosol Spectrometer, and/or a low-pressure Condensation Particle Counter (CPC) depending on the specific campaign. The science payloads varied with the campaign objectives, but the aerosol data were invariably acquired in conjunction with measurements by other investigators placing them in the context of atmospheric composition. The archive includes location and time of the measurements along with the tropopause heights and selected atmospheric composition and state data such as ambient temperatures and pressures, abundances of ozone, N2O, oxides of nitrogen, water vapor, CO2 etc. The data archive is stored in NetCDF format and includes all relevant metadata for measured quantities. This archive will be hosted by NASA and will be available to the public for model validation. The data includes indexing by scientific campaign, date, and spatial coordinates. This will facilitate comparisons across the available range of times, locations and related measurements. This data set has been used for validation of satellite remote sensing data. Coincident measurements of aerosol size distributions were used to calculate extinction profiles which were compared to those retrieved with the SAGE II satellite. Agreement between extinctions derived from the in situ size measurements and those provided by SAGE II was good for the 452, 525, and 1020 nm wavelength channels, but poor for

  18. Water uptake by organic aerosol and its influence on gas/particle partitioning of secondary organic aerosol in the United States

    NASA Astrophysics Data System (ADS)

    Jathar, Shantanu H.; Mahmud, Abdullah; Barsanti, Kelley C.; Asher, William E.; Pankow, James F.; Kleeman, Michael J.

    2016-03-01

    Organic aerosol (OA) is at least partly hygroscopic, i.e., water partitions into the organic phase to a degree determined by the relative humidity (RH), the organic chemical composition, and the particle size. This organic-phase water increases the aerosol mass and provides a larger absorbing matrix while decreasing its mean molecular weight, which can encourage additional condensation of semi-volatile organic compounds. Most regional and global atmospheric models account for water uptake by inorganic salts but do not explicitly account for organic-phase water and its subsequent impact on gas/particle partitioning of semi-volatile OA. In this work, we incorporated the organic-phase water model described by Pankow et al. (2015) into the UCD/CIT air quality model to simulate water uptake by OA and assessed its influence on total OA mass concentrations. The model was run for one summer month over two distinct regions: South Coast Air Basin (SoCAB) surrounding Los Angeles, California and the eastern United States (US). In SoCAB where the OA was dominated by non-hygroscopic primary OA (POA), there was very little organic-phase water uptake (0.1-0.2 μg m-3) and consequently very little enhancement (or growth) in total OA concentrations (OA + organic-phase water): a 3% increase in total OA mass was predicted for a 0.1 increase in relative humidity. In contrast, in the eastern US where secondary OA (SOA) from biogenic sources dominated the OA, substantial organic-phase water uptake and enhancement in total OA concentrations was predicted, even in urban locations. On average, the model predicted a 20% growth in total OA mass for a 0.1 increase in relative humidity; the growth was equivalent to a 250 nm particle with a hygroscopicity parameter (κ) of 0.15. Further, for the same relative humidity, the exact extent of organic-phase water uptake and total OA enhancement was found to be dependent on the particle mixing state. When the source-oriented mixing state of aerosols

  19. Predicting the aerosol performance of dry powder inhalation formulations by interparticulate interaction analysis using inverse gas chromatography.

    PubMed

    Tong, Henry H Y; Shekunov, Boris Y; York, Peter; Chow, Albert H L

    2006-01-01

    Previous studies have demonstrated the utility of inverse gas chromatography (IGC) in discriminating the differences in surface energy between salmeterol xinafoate (SX) powders prepared by conventional sequential batch crystallization and micronization and by supercritical fluid crystallization. In the present study, solubility parameters derived from IGC analysis at infinite dilution (zero coverage) were further utilized to evaluate the influence of solid-solid interactions on the in vitro aerosol performance of these SX samples, with or without the inclusion of a lactose carrier. To this end, the strength of cohesive SX-SX interactions and that of adhesive SX-lactose interactions were computed for the samples from the corresponding solubility parameters, and their fine particle fractions determined using a multi-stage liquid impinger. It was found that the aerosol performance of SX could be substantially improved by the addition of lactose carrier only if the adhesive SX-lactose interactions were stronger than the cohesive SX-SX interactions. The difference in strength between these two forms of interactions also displayed a significant correlation with the increase in fine particle fraction after the addition of lactose carrier. These results suggest that IGC-based interparticulate interaction measurements may serve as a useful means for predicting the aerosol performance of dry powder inhalation formulations.

  20. Earth Science With the Stratospheric Aerosol and Gas Experiment III (SAGE III) on the International Space Station

    NASA Technical Reports Server (NTRS)

    Zawodny, Joe; Vernier, Jean-Paul; Thomason, Larry; Roell, Marilee; Pitts, Mike; Moore, Randy; Hill, Charles; Flittner, David; Damadeo, Rob; Cisewski, Mike

    2015-01-01

    The Stratospheric Aerosol and Gas Experiment (SAGE) III is the fourth generation of solar occultation instruments operated by NASA, the first coming under a different acronym, to investigate the Earth's upper atmosphere. Three flight-ready SAGE III instruments were built by Ball Aerospace in the late 1990s, with one launched aboard the former Russian Aviation and Space Agency (now known as Roskosmos) Meteor-3M platform on 10 December 2001 (continuing until the platform lost power in 2006). Another of the original instruments was manifested for the ISS in the 2004 time frame, but was delayed because of budgetary considerations. Fortunately, that SAGE III/ISS mission was restarted in 2009 with a major focus upon filling an anticipated gap in ozone and aerosol observation in the second half of this decade. Here we discuss the mission architecture, its implementation, and data that will be produced by SAGE III/ISS, including their expected accuracy and coverage. The 52-degree inclined orbit of the ISS is well-suited for solar occultation and provides near-global observations on a monthly basis with excellent coverage of low and mid-latitudes. This is similar to that of the SAGE II mission (1985-2005), whose data set has served the international atmospheric science community as a standard for stratospheric ozone and aerosol measurements. The nominal science products include vertical profiles of trace gases, such as ozone, nitrogen dioxide and water vapor, along with multi-wavelength aerosol extinction. Though in the visible portion of the spectrum the brightness of the Sun is one million times that of the full Moon, the SAGE III instrument is designed to cover this large dynamic range and also perform lunar occultations on a routine basis to augment the solar products. The standard lunar products were demonstrated during the SAGE III/M3M mission and include ozone, nitrogen dioxide & nitrogen trioxide. The operational flexibility of the SAGE III spectrometer accomplishes

  1. Modelling non-equilibrium secondary organic aerosol formation and evaporation with the aerosol dynamics, gas- and particle-phase chemistry kinetic multilayer model ADCHAM

    NASA Astrophysics Data System (ADS)

    Roldin, P.; Eriksson, A. C.; Nordin, E. Z.; Hermansson, E.; Mogensen, D.; Rusanen, A.; Boy, M.; Swietlicki, E.; Svenningsson, B.; Zelenyuk, A.; Pagels, J.

    2014-08-01

    We have developed the novel Aerosol Dynamics, gas- and particle-phase chemistry model for laboratory CHAMber studies (ADCHAM). The model combines the detailed gas-phase Master Chemical Mechanism version 3.2 (MCMv3.2), an aerosol dynamics and particle-phase chemistry module (which considers acid-catalysed oligomerization, heterogeneous oxidation reactions in the particle phase and non-ideal interactions between organic compounds, water and inorganic ions) and a kinetic multilayer module for diffusion-limited transport of compounds between the gas phase, particle surface and particle bulk phase. In this article we describe and use ADCHAM to study (1) the evaporation of liquid dioctyl phthalate (DOP) particles, (2) the slow and almost particle-size-independent evaporation of α-pinene ozonolysis secondary organic aerosol (SOA) particles, (3) the mass-transfer-limited uptake of ammonia (NH3) and formation of organic salts between ammonium (NH4+) and carboxylic acids (RCOOH), and (4) the influence of chamber wall effects on the observed SOA formation in smog chambers. ADCHAM is able to capture the observed α-pinene SOA mass increase in the presence of NH3(g). Organic salts of ammonium and carboxylic acids predominantly form during the early stage of SOA formation. In the smog chamber experiments, these salts contribute substantially to the initial growth of the homogeneously nucleated particles. The model simulations of evaporating α-pinene SOA particles support the recent experimental findings that these particles have a semi-solid tar-like amorphous-phase state. ADCHAM is able to reproduce the main features of the observed slow evaporation rates if the concentration of low-volatility and viscous oligomerized SOA material at the particle surface increases upon evaporation. The evaporation rate is mainly governed by the reversible decomposition of oligomers back to monomers. Finally, we demonstrate that the mass-transfer-limited uptake of condensable organic compounds

  2. Chromatographic hydrogen isotope separation

    DOEpatents

    Aldridge, F.T.

    Intermetallic compounds with the CaCu/sub 5/ type of crystal structure, particularly LaNiCo/sub 4/ and CaNi/sub 5/, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation column. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale multi-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen cn produce large quantities of heavy water at an effective cost for use in heavy water reactors.

  3. Chromatographic hydrogen isotope separation

    DOEpatents

    Aldridge, Frederick T.

    1981-01-01

    Intermetallic compounds with the CaCu.sub.5 type of crystal structure, particularly LaNiCo.sub.4 and CaNi.sub.5, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation colum. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale mutli-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen can produce large quantities of heavy water at an effective cost for use in heavy water reactors.

  4. A study on characterization of stratospheric aerosol and gas parameters with the spacecraft solar occultation experiment

    NASA Technical Reports Server (NTRS)

    Chu, W. P.

    1977-01-01

    Spacecraft remote sensing of stratospheric aerosol and ozone vertical profiles using the solar occultation experiment has been analyzed. A computer algorithm has been developed in which a two step inversion of the simulated data can be performed. The radiometric data are first inverted into a vertical extinction profile using a linear inversion algorithm. Then the multiwavelength extinction profiles are solved with a nonlinear least square algorithm to produce aerosol and ozone vertical profiles. Examples of inversion results are shown illustrating the resolution and noise sensitivity of the inversion algorithms.

  5. Application of mobile aerosol and trace gas measurements for the investigation of megacity air pollution emissions: the Paris metropolitan area

    NASA Astrophysics Data System (ADS)

    von der Weiden-Reinmüller, S.-L.; Drewnick, F.; Crippa, M.; Prévôt, A. S. H.; Meleux, F.; Baltensperger, U.; Beekmann, M.; Borrmann, S.

    2014-01-01

    For the investigation of megacity emission development and the impact outside the source region, mobile aerosol and trace gas measurements were carried out in the Paris metropolitan area between 1 July and 31 July 2009 (summer conditions) and 15 January and 15 February 2010 (winter conditions) in the framework of the European Union FP7 MEGAPOLI project. Two mobile laboratories, MoLa and MOSQUITA, were deployed, and here an overview of these measurements and an investigation of the applicability of such measurements for the analysis of megacity emissions are presented. Both laboratories measured physical and chemical properties of fine and ultrafine aerosol particles as well as gas phase constituents of relevance for urban pollution scenarios. The applied measurement strategies include cross-section measurements for the investigation of plume structure and quasi-Lagrangian measurements axially along the flow of the city's pollution plume to study plume aging processes. Results of intercomparison measurements between the two mobile laboratories represent the adopted data quality assurance procedures. Most of the compared measurement devices show sufficient agreement for combined data analysis. For the removal of data contaminated by local pollution emissions a video tape analysis method was applied. Analysis tools like positive matrix factorization and peak integration by key analysis applied to high-resolution time-of-flight aerosol mass spectrometer data are used for in-depth data analysis of the organic particulate matter. Several examples, including a combination of MoLa and MOSQUITA measurements on a cross section through the Paris emission plume, are provided to demonstrate how such mobile measurements can be used to investigate the emissions of a megacity. A critical discussion of advantages and limitations of mobile measurements for the investigation of megacity emissions completes this work.

  6. Design and characterization of a smog chamber for studying gas-phase chemical mechanisms and aerosol formation

    NASA Astrophysics Data System (ADS)

    Wang, X.; Liu, T.; Bernard, F.; Ding, X.; Wen, S.; Zhang, Y.; Zhang, Z.; He, Q.; Lü, S.; Chen, J.; Saunders, S.; Yu, J.

    2014-01-01

    We describe here characterization of a new state-of-the-art smog chamber facility for studying atmospheric gas-phase and aerosol chemistry. The chamber consists of a 30 m3 fluorinated ethylene propylene (FEP) Teflon film reactor housed in a temperature-controlled enclosure equipped with black lamps as the light source. Temperature can be set in the range from -10 to 40 °C at accuracy of ±1 °C as measured by eight temperature sensors inside the enclosure and one just inside the reactor. Matrix air can be purified with non-methane hydrocarbons (NMHCs) < 0.5 ppb, NOx/O3/carbonyls < 1 ppb and particles < 1 cm-3. The photolysis rate of NO2 is adjustable between 0 and 0.49 min-1. At 298 K under dry conditions, the average wall loss rates of NO, NO2 and O3 were measured to be 1.41 × 10-4 min-1, 1.39 × 10-4 min-1 and 1.31 × 10-4 min-1, respectively, and the particle number wall loss rate was measured to be 0.17 h-1. Auxiliary mechanisms of this chamber are determined and included in the Master Chemical Mechanism to evaluate and model propene-NOx-air irradiation experiments. The results indicate that this new smog chamber can provide high-quality data for mechanism evaluation. Results of α-pinene dark ozonolysis experiments revealed secondary organic aerosol (SOA) yields comparable to those from other chamber studies, and the two-product model gives a good fit for the yield data obtained in this work. Characterization experiments demonstrate that our Guangzhou Institute of Geochemistry, Chinese Academy Sciences (GIG-CAS), smog chamber facility can be used to provide valuable data for gas-phase chemistry and secondary aerosol formation.

  7. Application of mobile aerosol and trace gas measurements for the investigation of megacity air pollution emissions: the Paris metropolitan area

    NASA Astrophysics Data System (ADS)

    von der Weiden-Reinmüller, S.-L.; Drewnick, F.; Crippa, M.; Prévôt, A. S. H.; Meleux, F.; Baltensperger, U.; Beekmann, M.; Borrmann, S.

    2013-08-01

    For the investigation of megacity emission development and impact outside the source region mobile aerosol and trace gas measurements were carried out in the Paris metropolitan area between 1 July and 31 July 2009 (summer conditions) and 15 January and 15 February 2010 (winter conditions) in the framework of the European Union FP7 MEGAPOLI project. Two mobile laboratories, MoLa and MOSQUITA, were deployed, and here an overview of these measurements and an investigation of the applicability of such measurements for the analysis of megacity emissions are presented. Both laboratories measured physical and chemical properties of fine and ultrafine aerosol particles as well as gas phase constituents of relevance for urban pollution scenarios. The applied measurement strategies include cross section measurements for the investigation of plume structure and quasi-Lagrangian measurements radially away from the city center to study plume aging processes. Results of intercomparison measurements between the two mobile laboratories represent the adopted data quality assurance procedures. Most of the compared measurement devices show sufficient agreement for combined data analysis. For the removal of data contaminated by local pollution emissions a video tape analysis method was applied. Analysis tools like positive matrix factorization and peak integration by key analysis applied to high-resolution time-of-flight aerosol mass spectrometer data are used for in-depth data analysis of the organic particulate matter. Several examples, including a combination of MoLa and MOSQUITA measurements on a cross section through the Paris emission plume are provided to demonstrate how such mobile measurements can be used to investigate the emissions of a megacity. A critical discussion of advantages and limitations of mobile measurements for the investigation of megacity emissions completes this work.

  8. Trace Gas/Aerosol Boundary Concentrations and their Impacts on Continental-scale AQMEII Modelling Domains

    EPA Science Inventory

    Over twenty modeling groups are participating in the Air Quality Model Evaluation International Initiative (AQMEII) in which a variety of mesoscale photochemical and aerosol air quality modeling systems are being applied to continental-scale domains in North America and Europe fo...

  9. The effect of interactive gas-phase chemistry and aerosols on climate simulations over the last millennium

    NASA Astrophysics Data System (ADS)

    Tsigaridis, K.; LeGrande, A. N.; Healy, R. J.; Schmidt, G. A.

    2013-12-01

    Significant computational resources are required for long transient simulations using coupled atmosphere-ocean general circulation models. Individual simulations from the NINT version of GISS ModelE-R (part of the CMIP5 archive) of the last millennium, from year 850 to 2005, enabled with only 3 water isotopologue tracers, required ~9 months of computational time on the state-of-the-art parallel computing cluster of NCCS. The additional requirements of the full chemistry module would increase this by a factor of ~3. And yet, it is well known that chemistry and aerosols are very important on climate, both regional and global. Therefore, we have designed a set of experiments where the ocean and sea ice boundary conditions of the coupled model, paired with the land surface, greenhouse gases, insolation, and total solar irradiance (TSI) forcing from the PMIP3 protocol are applied to a series of full-chemistry GISS ModelE snap-shots each 50-years through the last millennium. We will present results from atmosphere-only model simulations with the GISS ModelE, which includes interactive gas-phase chemistry and aerosols at decadal-scale time slices, driven by millennial-length simulations performed with the same model when coupled with an ocean model. The boundary conditions for the transient simulations follow the last millennium coordinated PMIP3 experiment protocol. This experiment directly links in with other pre-industrial experiments being completed as part of IPCC AR5, using the same model and resolution as in GISS IPCC AR5. The impact of the presence of short-lived gases and aerosols on the simulated climate is studied. The role of previously omitted forcing mechanisms will be performed during the whole simulated period. The results presented are the initial runs from a larger set of experiments that will assess the climate impact of changes to dust, sea-salt, and ocean-derived sulfate, biomass burning ozone-precursors and aerosols, organic carbon, wetland methane

  10. Chromatographic methods in the study of autism.

    PubMed

    Żurawicz, Ewa; Kałużna-Czaplińska, Joanna; Rynkowski, Jacek

    2013-10-01

    Research into biomarkers of autism is a new means of medical intervention in this disease. Chromatographic techniques, especially coupled with mass spectrometry, are widely used in determination of biomarkers and assessment of effectiveness of autism therapy owing to their sensitivity and selectivity. Among the chromatographic techniques gas chromatography and liquid chromatography, especially high-performance liquid chromatography, have found application in clinical trials. The high-performance liquid chromatography technique allows an analysis of liquid samples with a wide range of molecules, small and large, providing an opportunity to perform advanced assays within a short time frame. Gas chromatography with the appropriate preparation of samples (gaseous and liquid) and a selection of analysis conditions enables the separation of thermally stable, volatile and non-volatile organic substances in short runtimes. The chromatographic techniques that are currently used in metabolic studies in autism are designed to identify abnormalities in three areas: the metabolism of neurotransmitters, nutritional and metabolic status and manifestations of oxidative stress. This review presents a necessary theoretical introduction and examples of applications of chromatographic studies of disorder markers in autism.

  11. Kinetic regimes and limiting cases of gas uptake and heterogeneous reactions in atmospheric aerosols and clouds: a general classification scheme

    NASA Astrophysics Data System (ADS)

    Berkemeier, Thomas; Huisman, Andrew J.; Ammann, Markus; Shiraiwa, Manabu; Koop, Thomas; Pöschl, Ulrich

    2013-04-01

    Heterogeneous reactions are important to atmospheric chemistry and are therefore an area of intense research. In multiphase systems such as aerosols and clouds, chemical reactions are usually strongly coupled to a complex sequence of mass transport processes and results are often not easy to interpret. Here we present a systematic classification scheme for gas uptake by aerosol or cloud particles which distinguishes two major regimes: a reaction-diffusion regime and a mass-transfer regime. Each of these regimes includes four distinct limiting cases, characterized by a dominant reaction location (surface or bulk) and a single rate-limiting process: chemical reaction, bulk diffusion, gas-phase diffusion or mass accommodation. The conceptual framework enables efficient comparison of different studies and reaction systems, going beyond the scope of previous classification schemes by explicitly resolving interfacial transport processes and surface reactions limited by mass transfer from the gas phase. The use of kinetic multi-layer models instead of resistor model approaches increases the flexibility and enables a broader treatment of the subject, including cases which do not fit into the strict limiting cases typical of most resistor model formulations. The relative importance of different kinetic parameters such as diffusion, reaction rate and accommodation coefficients in this system is evaluated by a quantitative global sensitivity analysis. We outline the characteristic features of each limiting case and discuss the potential relevance of different regimes and limiting cases for various reaction systems. In particular, the classification scheme is applied to three different data sets for the benchmark system of oleic acid reacting with ozone. In light of these results, future directions of research needed to elucidate the multiphase chemical kinetics in this and other reaction systems are discussed. Reference: Berkemeier, T., Huisman, A. J., Ammann, M., Shiraiwa, M

  12. Megacity emission plume characteristics in summer and winter investigated by mobile aerosol and trace gas measurements: the Paris metropolitan area

    NASA Astrophysics Data System (ADS)

    von der Weiden-Reinmüller, S.-L.; Drewnick, F.; Zhang, Q. J.; Freutel, F.; Beekmann, M.; Borrmann, S.

    2014-12-01

    For the investigation of megacity emission plume characteristics mobile aerosol and trace gas measurements were carried out in the greater Paris region in July 2009 and January-February 2010 within the EU FP7 MEGAPOLI project (Megacities: Emissions, urban, regional and Global Atmospheric POLlution and climate effects, and Integrated tools for assessment and mitigation). The deployed instruments measured physical and chemical properties of sub-micron aerosol particles, gas phase constituents of relevance for urban air pollution studies and meteorological parameters. The emission plume was identified based on fresh pollutant (e.g., particle-bound polycyclic aromatic hydrocarbons, black carbon, CO2 and NOx) concentration changes in combination with wind direction data. The classification into megacity influenced and background air masses allowed a characterization of the emission plume during summer and winter environmental conditions. On average, a clear increase of fresh pollutant concentrations in plume compared to background air masses was found for both seasons. For example, an average increase of 190% (+ 8.8 ng m-3) in summer and of 130% (+ 18.1 ng m-3) in winter was found for particle-bound polycyclic aromatic hydrocarbons in plume air masses. The aerosol particle size distribution in plume air masses was influenced by nucleation and growth due to coagulation and condensation in summer, while in winter only the latter process (i.e., particle growth) seemed to be initiated by urban pollution. The observed distribution of fresh pollutants in the emission plume - its cross sectional Gaussian-like profile and the exponential decrease of pollutant concentrations with increasing distance to the megacity - are in agreement with model results. Differences between model and measurements were found for plume center location, plume width and axial plume extent. In general, dilution was identified as the dominant process determining the axial variations within the Paris

  13. Megacity emission plume characteristics in summer and winter investigated by mobile