Milking performance evaluation and factors affecting milking claw vacuum levels with flow simulator.
Enokidani, Masafumi; Kawai, Kazuhiro; Shinozuka, Yasunori; Watanabe, Aiko
2017-08-01
Milking performance of milking machines that matches the production capability of dairy cows is important in reducing the risk of mastitis, particularly in high-producing cows. This study used a simulated milking device to examine the milking performance of the milking system of 73 dairy farms and to analyze the factors affecting claw vacuum. Mean claw vacuum and range of fluctuation of claw vacuum (claw vacuum range) were measured at three different flow rates: 5.7, 7.6 and 8.7 kg/min. At the highest flow rate, only 16 farms (21.9%) met both standards of mean claw vacuum ≥35 kPa and claw vacuum range ≤ 7 kPa, showing that milking systems currently have poor milking performance. The factors affecting mean claw vacuum were claw type, milk-meter and vacuum shut-off device; the factor affecting claw vacuum range was claw type. Examination of the milking performance of the milking system using a simulated milking device allows an examination of the performance that can cope with high producing cows, indicating the possibility of reducing the risk of mastitis caused by inappropriate claw vacuum. © 2016 Japanese Society of Animal Science.
Factors Affecting Open-Set Word Recognition in Adults with Cochlear Implants
Holden, Laura K.; Finley, Charles C.; Firszt, Jill B.; Holden, Timothy A.; Brenner, Christine; Potts, Lisa G.; Gotter, Brenda D.; Vanderhoof, Sallie S.; Mispagel, Karen; Heydebrand, Gitry; Skinner, Margaret W.
2012-01-01
A monosyllabic word test was administered to 114 postlingually-deaf adult cochlear implant (CI) recipients at numerous intervals from two weeks to two years post-initial CI activation. Biographic/audiologic information, electrode position, and cognitive ability were examined to determine factors affecting CI outcomes. Results revealed that Duration of Severe-to-Profound Hearing Loss, Age at Implantation, CI Sound-field Threshold Levels, Percentage of Electrodes in Scala Vestibuli, Medio-lateral Electrode Position, Insertion Depth, and Cognition were among the factors that affected performance. Knowledge of how factors affect performance can influence counseling, device fitting, and rehabilitation for patients and may contribute to improved device design. PMID:23348845
Effects of input device and motion type on a cursor-positioning task.
Yau, Yi-Jan; Hwang, Sheue-Ling; Chao, Chin-Jung
2008-02-01
Many studies have investigated the performance of using nonkey-board input devices under static situations, but few have considered the effects of motion type on manipulating these input devices. In this study comparison of 12 mens' performance using four input devices (three trackballs: currently used, trackman wheel, and erectly held trackballs, as well as a touch screen) under five motion types of static, heave, roll, pitch, and random movements was conducted. The input device and motion type significantly affected movement speed and accuracy, and their interaction significantly affected the movement speed. The touch screen was the fastest but the least accurate input device. The erectly held trackball was the slowest, whereas the error rate of the currently used trackball was the lowest. Impairments of the random motion on movement time and error rate were larger than those of other motion types. Considering objective and subjective evaluations, the trackman wheel and currently used trackball were more efficient in operation than the erectly held trackball and touch screen under the motion environments.
CFD Design and Analysis of a Passively Suspended Tesla Pump Left Ventricular Assist Device
Medvitz, Richard B.; Boger, David A.; Izraelev, Valentin; Rosenberg, Gerson; Paterson, Eric G.
2012-01-01
This paper summarizes the use of computational fluid dynamics (CFD) to design a novelly suspended Tesla LVAD. Several design variants were analyzed to study the parameters affecting device performance. CFD was performed at pump speeds of 6500, 6750 and 7000 RPM and at flow rates varying from 3 to 7 liter-per-minute (LPM). The CFD showed that shortening the plates nearest the pump inlet reduced the separations formed beneath the upper plate leading edges and provided a more uniform flow distribution through the rotor gaps, both of which positively affected the device hydrodynamic performance. The final pump design was found to produce a head rise of 77 mmHg with a hydraulic efficiency of 16% at the design conditions of 6 LPM throughflow and a 6750 RPM rotation rate. To assess the device hemodynamics the strain rate fields were evaluated. The wall shear stresses demonstrated that the pump wall shear stresses were likely adequate to inhibit thrombus deposition. Finally, an integrated field hemolysis model was applied to the CFD results to assess the effects of design variation and operating conditions on the device hemolytic performance. PMID:21595722
Digital Devices, Distraction, and Student Performance: Does In-Class Cell Phone Use Reduce Learning?
ERIC Educational Resources Information Center
Duncan, Douglas K.; Hoekstra, Angel R.; Wilcox, Bethany R.
2012-01-01
The recent increase in use of digital devices such as laptop computers, iPads, and web-enabled cell phones has generated concern about how technologies affect student performance. Combining observation, survey, and interview data, this research assesses the effects of technology use on student attitudes and learning. Data were gathered in eight…
Inverse design engineering of all-silicon polarization beam splitters
NASA Astrophysics Data System (ADS)
Frandsen, Lars H.; Sigmund, Ole
2016-03-01
Utilizing the inverse design engineering method of topology optimization, we have realized high-performing all-silicon ultra-compact polarization beam splitters. We show that the device footprint of the polarization beam splitter can be as compact as ~2 μm2 while performing experimentally with a polarization splitting loss lower than ~0.82 dB and an extinction ratio larger than ~15 dB in the C-band. We investigate the device performance as a function of the device length and find a lower length above which the performance only increases incrementally. Imposing a minimum feature size constraint in the optimization is shown to affect the performance negatively and reveals the necessity for light to scatter on a sub-wavelength scale to obtain functionalities in compact photonic devices.
Seif, Johannes P.; Krishnamani, Gopal; Demaurex, Benedicte; ...
2015-03-02
Silicon heterojunction (SHJ) solar cells feature amorphous silicon passivation films, which enable very high voltages. We report how such passivation increases with operating temperature for amorphous silicon stacks involving doped layers and decreases for intrinsic-layer-only passivation. We discuss the implications of this phenomenon on the solar cell's temperature coefficient, which represents an important figure-of-merit for the energy yield of devices deployed in the field. We show evidence that both open-circuit voltage (Voc) and fill factor (FF) are affected by these variations in passivation and quantify these temperature-mediated effects, compared with those expected from standard diode equations. We confirm that devicesmore » with high Voc values at 25°C show better high-temperature performance. Thus, we also argue that the precise device architecture, such as the presence of charge-transport barriers, may affect the temperature-dependent device performance as well.« less
Bae, Sungwoo; Kim, Myungchin
2016-01-01
In order to realize a true WoT environment, a reliable power circuit is required to ensure interconnections among a range of WoT devices. This paper presents research on sensors and their effects on the reliability and response characteristics of power circuits in WoT devices. The presented research can be used in various power circuit applications, such as energy harvesting interfaces, photovoltaic systems, and battery management systems for the WoT devices. As power circuits rely on the feedback from voltage/current sensors, the system performance is likely to be affected by the sensor failure rates, sensor dynamic characteristics, and their interface circuits. This study investigated how the operational availability of the power circuits is affected by the sensor failure rates by performing a quantitative reliability analysis. In the analysis process, this paper also includes the effects of various reconstruction and estimation techniques used in power processing circuits (e.g., energy harvesting circuits and photovoltaic systems). This paper also reports how the transient control performance of power circuits is affected by sensor interface circuits. With the frequency domain stability analysis and circuit simulation, it was verified that the interface circuit dynamics may affect the transient response characteristics of power circuits. The verification results in this paper showed that the reliability and control performance of the power circuits can be affected by the sensor types, fault tolerant approaches against sensor failures, and the response characteristics of the sensor interfaces. The analysis results were also verified by experiments using a power circuit prototype. PMID:27608020
NASA Astrophysics Data System (ADS)
Xia, Yingdong; Chen, Yonghua; Smith, Gregory M.; Li, Yuan; Huang, Wenxiao; Carroll, David L.
2013-06-01
In this work, the effects of electrode modification by calcium (Ca) on the performance of AC field induced polymer electroluminescence (FIPEL) devices are studied. The FIPEL device with Ca/Al electrode exhibits 550 cd m-2, which is 27.5 times higher than that of the device with only an Al electrode (20 cd m-2). Both holes and electrons are injected from one electrode in our FIPEL device. We found that the electron injection can be significantly enhanced by a Ca modification on the Al electrode without greatly affecting the hole injection. Therefore, the electrons and holes can be effectively recombined in the emissive layer to form more excitons under the AC voltage, leading to effective light emission. The device emitted much brighter light than other AC-based organic EL devices. This result provides an easy and effective way to improve FIPEL performance.
Lee, John D; Roberts, Shannon C; Hoffman, Joshua D; Angell, Linda S
2012-04-01
The aim of this study was to assess how scrolling through playlists on an MP3 player or its aftermarket controller affects driving performance and to examine how drivers adapt device use to driving demands. Drivers use increasingly complex infotainment devices that can undermine driving performance. The goal activation hypothesis suggests that drivers might fail to compensate for these demands, particularly with long tasks and large search set sizes. A total of 50 participants searched for songs in playlists of varying lengths using either an MP3 player or an aftermarket controller while negotiating road segments with traffic and construction in a medium-fidelity driving simulator. Searching through long playlists (580 songs) resulted in poor driving performance and required more long glances (longer than 2 s) to the device compared with other playlist lengths. The aftermarket controller also led to more long glances compared with the MP3 player. Drivers did not adequately adapt their behavior to roadway demand, as evident in their degraded driving performance. No significant performance differences were found between short playlists, the radio-tuning task, and the no-task condition. Selecting songs from long playlists undermined driving performance, and drivers did not sufficiently adapt their use of the device to the roadway demands, consistent with the goal activation hypothesis. The aftermarket controller degraded rather than enhanced performance. Infotainment systems should support drivers in managing distraction. Aftermarket controllers can have the unintended effect of making devices carried into the car less compatible with driving.These results can motivate development of new interfaces as alternatives to scrolling lists.
Jones, R P; Conway, D H
2005-08-01
Electromagnetic interference produced by wireless communication can affect medical devices and hospital policies exist to address this risk. During the transfer of ventilated patients, these policies may be compromised by essential communication between base and receiving hospitals. Local wireless networks (e.g. Bluetooth) may reduce the 'spaghetti syndrome' of wires and cables seen on intensive care units, but also generate electromagnetic interference. The aim of this study was to investigate these effects on displayed and actual ventilator performance. Five ventilators were tested: Drager Oxylog 2000, BREAS LTV-1000, Respironics BiPAP VISION, Puritan Bennett 7200 and 840. Electromagnetic interference was generated by three devices: Simoco 8020 radio handset, Nokia 7210 and Nokia 6230 mobile phone, Nokia 6230 communicating via Bluetooth with a Palm Tungsten T Personal Digital Assistant. We followed the American National Standard Recommended Practice for On-Site, Ad Hoc Testing (ANSI C63) for electromagnetic interference. We used a ventilator tester, to simulate healthy adult lungs and measure ventilator performance. The communication device under test was moved in towards each ventilator from a distance of 1 m in six axes. Alarms or error codes on the ventilator were recorded, as was ventilator performance. All ventilators tested, except for the Respironics VISION, showed a display error when subjected to electromagnetic interference from the Nokia phones and Simoco radio. Ventilator performance was only affected by the radio which caused the Puritan Bennett 840 to stop functioning completely. The transfer ventilators' performance were not affected by radio or mobile phone, although the mobile phone did trigger a low-power alarm. Effects on intensive care ventilators included display reset, with the ventilator restoring normal display function within 2 s, and low-power/low-pressure alarms. Bluetooth transmission had no effect on the function of all the ventilators tested. In a clinical setting, high-power-output devices such as a two-way radio may cause significant interference in ventilator function. Medium-power-output devices such as mobile phones may cause minor alarm triggers. Low-power-output devices such as Bluetooth appear to cause no interference with ventilator function.
A Context-Aware Model to Provide Positioning in Disaster Relief Scenarios
Moreno, Daniel; Ochoa, Sergio F.; Meseguer, Roc
2015-01-01
The effectiveness of the work performed during disaster relief efforts is highly dependent on the coordination of activities conducted by the first responders deployed in the affected area. Such coordination, in turn, depends on an appropriate management of geo-referenced information. Therefore, enabling first responders to count on positioning capabilities during these activities is vital to increase the effectiveness of the response process. The positioning methods used in this scenario must assume a lack of infrastructure-based communication and electrical energy, which usually characterizes affected areas. Although positioning systems such as the Global Positioning System (GPS) have been shown to be useful, we cannot assume that all devices deployed in the area (or most of them) will have positioning capabilities by themselves. Typically, many first responders carry devices that are not capable of performing positioning on their own, but that require such a service. In order to help increase the positioning capability of first responders in disaster-affected areas, this paper presents a context-aware positioning model that allows mobile devices to estimate their position based on information gathered from their surroundings. The performance of the proposed model was evaluated using simulations, and the obtained results show that mobile devices without positioning capabilities were able to use the model to estimate their position. Moreover, the accuracy of the positioning model has been shown to be suitable for conducting most first response activities. PMID:26437406
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bradshaw, Nathan P.; Severt, Sean Y.; Wang, Zhaoying
Biocompatible materials capable of controlled actuation under biologically relevant conditions are in high demand for use in a number of biomedical applications. Recently, we demonstrated that a composite material composed of silk biopolymer and the conducting polymer poly(pyrrole) can bend under an applied voltage using a simple bilayer device. Here we present further characterization of these bilayer actuators using time of flight secondary ion mass spectrometry, and provide clarification on the mechanism of actuation and factors affecting device performance and stability. We will discuss the results of this study in the context of strategies for optimization of device performance.
Characterization of crosstalk in stereoscopic display devices.
Zafar, Fahad; Badano, Aldo
2014-12-01
Many different types of stereoscopic display devices are used for commercial and research applications. Stereoscopic displays offer the potential to improve performance in detection tasks for medical imaging diagnostic systems. Due to the variety of stereoscopic display technologies, it remains unclear how these compare with each other for detection and estimation tasks. Different stereo devices have different performance trade-offs due to their display characteristics. Among them, crosstalk is known to affect observer perception of 3D content and might affect detection performance. We measured and report the detailed luminance output and crosstalk characteristics for three different types of stereoscopic display devices. We recorded the effect of other issues on recorded luminance profiles such as viewing angle, use of different eye wear, and screen location. Our results show that the crosstalk signature for viewing 3D content can vary considerably when using different types of 3D glasses for active stereo displays. We also show that significant differences are present in crosstalk signatures when varying the viewing angle from 0 degrees to 20 degrees for a stereo mirror 3D display device. Our detailed characterization can help emulate the effect of crosstalk in conducting computational observer image quality assessment evaluations that minimize costly and time-consuming human reader studies.
DOT National Transportation Integrated Search
2017-12-01
The performance of pavement interface bonds affects the integrity of pavement structures. In current practice, tack coats are used to ensure sufficient bonding between asphalt concrete (AC) layers as well as AC and concrete or aggregate base layers. ...
Ju, Huanxin; Knesting, Kristina M; Zhang, Wei; Pan, Xiao; Wang, Chia-Hsin; Yang, Yaw-Wen; Ginger, David S; Zhu, Junfa
2016-01-27
A better understanding of how interfacial structure affects charge carrier recombination would benefit the development of highly efficient organic photovoltaic (OPV) devices. In this paper, transient photovoltage (TPV) and charge extraction (CE) measurements are used in combination with synchrotron radiation photoemission spectroscopy (SRPES) to gain insight into the correlation between interfacial properties and device performance. OPV devices based on PCDTBT/PC71BM with a Ca interlayer were studied as a reference system to investigate the interfacial effects on device performance. Devices with a Ca interlayer exhibit a lower recombination than devices with only an Al cathode at a given charge carrier density (n). In addition, the interfacial band structures indicate that the strong dipole moment produced by the Ca interlayer can facilitate the extraction of electrons and drive holes away from the cathode/polymer interface, resulting in beneficial reduction in interfacial recombination losses. These results help explain the higher efficiencies of devices made with Ca interlayers compared to that without the Ca interlayer.
Design of instructions for evacuating disabled adults.
Boyce, Michael W; Al-Awar Smither, Janan; Fisher, Daniel O; Hancock, P A
2017-01-01
We investigated how the design of instructions can affect performance in preparing emergency stair travel devices for the evacuation of disable individuals. We had three hypotheses: 1) Design of instructions would account for a significant portion of explained performance variance, 2) Improvements in design of instructions would reduce time on task across device type and age group, and 3) There would be a performance decrement for older adults compared to younger adults based on the slowing of older adult information processing abilities. Results showed that design of instructions does indeed account for a large portion of explained variance in the operation of emergency stair travel devices, and that improvements in design of instructions can reduce time on task across device type and age group. However, encouragingly for real-world operations, results did not indicate any significant differences between older versus younger adults. We look to explore ways that individuals with disabilities can exploit these insights to enhance the performance of emergency stair travel devices for use. Copyright © 2016 Elsevier Ltd. All rights reserved.
Unpacking the Black Box: Applications and Considerations for Using GPS Devices in Sport.
Malone, James J; Lovell, Ric; Varley, Matthew C; Coutts, Aaron J
2017-04-01
Athlete-tracking devices that include global positioning system (GPS) and microelectrical mechanical system (MEMS) components are now commonplace in sport research and practice. These devices provide large amounts of data that are used to inform decision making on athlete training and performance. However, the data obtained from these devices are often provided without clear explanation of how these metrics are obtained. At present, there is no clear consensus regarding how these data should be handled and reported in a sport context. Therefore, the aim of this review was to examine the factors that affect the data produced by these athlete-tracking devices and to provide guidelines for collecting, processing, and reporting of data. Many factors including device sampling rate, positioning and fitting of devices, satellite signal, and data-filtering methods can affect the measures obtained from GPS and MEMS devices. Therefore researchers are encouraged to report device brand/model, sampling frequency, number of satellites, horizontal dilution of precision, and software/firmware versions in any published research. In addition, details of inclusion/exclusion criteria for data obtained from these devices are also recommended. Considerations for the application of speed zones to evaluate the magnitude and distribution of different locomotor activities recorded by GPS are also presented, alongside recommendations for both industry practice and future research directions. Through a standard approach to data collection and procedure reporting, researchers and practitioners will be able to make more confident comparisons from their data, which will improve the understanding and impact these devices can have on athlete performance.
Oehl, M; Sutter, C
2015-05-01
With aging visual feedback becomes increasingly relevant in action control. Consequently, visual device and task characteristics should more and more affect tool use. Focussing on late working age, the present study aims to investigate age-related differences in processing task irrelevant (display size) and task relevant visual information (task difficulty). Young and middle-aged participants (20-35 and 36-64 years of age, respectively) sat in front of a touch screen with differently sized active touch areas (4″ to 12″) and performed pointing tasks with differing task difficulties (1.8-5 bits). Both display size and age affected pointing performance, but the two variables did not interact and aiming duration moderated both effects. Furthermore, task difficulty affected the pointing durations of middle-aged adults moreso than those of young adults. Again, aiming duration accounted for the variance in the data. The onset of an age-related decline in aiming duration can be clearly located in middle adulthood. Thus, the fine psychomotor ability "aiming" is a moderator and predictor for age-related differences in pointing tasks. The results support a user-specific design for small technical devices with touch interfaces. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Zabala-Travers, Silvina; Choi, Mina; Cheng, Wei-Chung
2015-01-01
Purpose: Even though the use of color in the interpretation of medical images has increased significantly in recent years, the ad hoc manner in which color is handled and the lack of standard approaches have been associated with suboptimal and inconsistent diagnostic decisions with a negative impact on patient treatment and prognosis. The purpose of this study is to determine if the choice of color scale and display device hardware affects the visual assessment of patterns that have the characteristics of functional medical images. Methods: Perfusion magnetic resonance imaging (MRI) was the basis for designing and performing experiments. Synthetic images resembling brain dynamic-contrast enhanced MRI consisting of scaled mixtures of white, lumpy, and clustered backgrounds were used to assess the performance of a rainbow (“jet”), a heated black-body (“hot”), and a gray (“gray”) color scale with display devices of different quality on the detection of small changes in color intensity. The authors used a two-alternative, forced-choice design where readers were presented with 600 pairs of images. Each pair consisted of two images of the same pattern flipped along the vertical axis with a small difference in intensity. Readers were asked to select the image with the highest intensity. Three differences in intensity were tested on four display devices: a medical-grade three-million-pixel display, a consumer-grade monitor, a tablet device, and a phone. Results: The estimates of percent correct show that jet outperformed hot and gray in the high and low range of the color scales for all devices with a maximum difference in performance of 18% (confidence intervals: 6%, 30%). Performance with hot was different for high and low intensity, comparable to jet for the high range, and worse than gray for lower intensity values. Similar performance was seen between devices using jet and hot, while gray performance was better for handheld devices. Time of performance was shorter with jet. Conclusions: Our findings demonstrate that the choice of color scale and display hardware affects the visual comparative analysis of pseudocolor images. Follow-up studies in clinical settings are being considered to confirm the results with patient images. PMID:26127048
Effect of semen preparation on casa motility results in cryopreserved bull spermatozoa.
Contri, Alberto; Valorz, Claudio; Faustini, Massimo; Wegher, Laura; Carluccio, Augusto
2010-08-01
Computer-assisted sperm analyzers (CASA) have become the standard tool for evaluating sperm motility and kinetic patterns because they provide objective data for thousands of sperm tracks. However, these devices are not ready-to-use and standardization of analytical practices is a fundamental requirement. In this study, we evaluated the effects of some settings, such as frame rate and frames per field, chamber and time of analysis, and samples preparations, including thawing temperature, sperm sample concentration, and media used for dilution, on the kinetic results of bovine frozen-thawed semen using a CASA. In Experiment 1, the frame rate (30-60 frame/s) significantly affected motility parameters, whereas the number of frames per field (30 or 45) did not seem to affect sperm kinetics. In Experiment 2, the thawing protocol affects sperm motility and kinetic parameters. Sperm sample concentration significantly limited the opportunity to perform the analysis and the kinetic results. A concentration of 100 and 50 x 10(6) sperm/mL limited the device's ability to perform the analysis or gave wrong results, whereas 5, 10, 20, and 30 x 10(6) sperm/mL concentrations allowed the analysis to be performed, but with different results (Experiment 3). The medium used for the dilution of the sample, which is fundamental for a correct sperm head detection, affects sperm motility results (Experiment 4). In this study, Makler and Leja chambers were used to perform the semen analysis with CASA devices. The chamber used significantly affected motility results (Experiment 5). The time between chamber loading and analysis affected sperm velocities, regardless of chamber used. Based on results recorded in this study, we propose that the CASA evaluation of motility of bovine frozen-thawed semen using Hamilton-Thorne IVOS 12.3 should be performed using a frame rate of 60 frame/s and 30 frames per field. Semen should be diluted at least at 20 x 10(6) sperm/mL using PBS. Furthermore, it is necessary to consider the type of chamber used and perform the analysis within 1 or 2 min, regardless of the chamber used. Copyright 2010 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Chen, Chih-Ming; Lin, Yu-Ju
2016-01-01
Despite the popularity of mobile reading devices, many studies have indicated that small screens restrict information transmission, adversely affecting reading performance on mobile devices. Moreover, mobile reading typically occurs in different reading contexts. Therefore, suitable text display type for mobile reading in different reading…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wendt, Joel Robert; Hadley, G. Ronald; Samora, Sally
Plasmonic structures open up new opportunities in photonic devices, sometimes offering an alternate method to perform a function and sometimes offering capabilities not possible with standard optics. In this LDRD we successfully demonstrated metal coatings on optical surfaces that do not adversely affect the transmission of those surfaces at the design frequency. This technology could be applied as an RF noise blocking layer across an optical aperture or as a method to apply an electric field to an active electro-optic device without affecting optical performance. We also demonstrated thin optical absorbers using similar patterned surfaces. These infrared optical antennas showmore » promise as a method to improve performance in mercury cadmium telluride detectors. Furthermore, these structures could be coupled with other components to lead to direct rectification of infrared radiation. This possibility leads to a new method for infrared detection and energy harvesting of infrared radiation.« less
Performance improvement of optical fiber coupler with electric heating versus gas heating.
Shuai, Cijun; Gao, Chengde; Nie, Yi; Peng, Shuping
2010-08-20
Gas heating has been widely used in the process of fused biconical tapering. However, as the instability and asymmetric flame temperature of gas heating exist, the performance of the optical devices fabricated by this method was affected. To overcome the problems resulting from gas combustion, an electric heater is designed and manufactured using a metal-ceramic (MoSi(2)) as a heating material. Our experimental data show that the fused-taper machine with an electric heater has improved the performance of optical devices by increasing the consistency of the extinction ratio, excess loss, and the splitting ratio over that of the previous gas heating mode. Microcrystallizations and microcracks were observed at the fused region of the polarization-maintaining (PM) fiber coupler and at the taper region with scanning electron microscopy and atomic force microscopy respectively. The distribution of the microcrystallizations and microcracks are nonuniform along the fiber with gas heating, while their distribution is rather uniform with electric heating. These findings show that the novel optical fiber coupler with an electric heater has improved the performance of optical fiber devices by affecting the consistency of the optical parameters and micromorphology of the surface of PM fiber.
Oosterhout, Stefan D.; Braunecker, Wade A.; Owczarczyk, Zbyslaw R.; ...
2017-04-27
The morphology of the bulk heterojunction absorber layer in an organic photovoltaic (OPV) device has a profound effect on the electrical properties and efficiency of the device. Previous work has consistently demonstrated that the solubilizing side-chains of the donor material affect these properties and device performance in a non-trivial way. Here, using Time-Resolved Microwave Conductivity (TRMC), we show by direct measurements of carrier lifetimes that the choice of side chains can also make a substantial difference in photocarrier dynamics. We have previously demonstrated a correlation between peak photoconductance measured by TRMC and device efficiencies; here, we demonstrate that TRMC photocarriermore » dynamics have an important bearing on device performance in a case study of devices made from donor materials with linear vs. branched side-chains and with variable active layer thicknesses. We use Grazing-Incidence Wide Angle X-ray Scattering to elucidate the cause of the different carrier lifetimes as a function of different aggregation behavior in the polymers. Consequently, the results help establish TRMC as a technique for screening OPV donor materials whose devices maintain performance in thick active layers (>250 nm) designed to improve light harvesting, film reproducibility, and ease of processing.« less
Lee, Tzu-Hsien
2005-12-01
This study examined the effects of operating a built-in touch-pad pointing device and a trackball mouse on participants' completion times, hand positions during operation, postural angles, and muscle activities. 8 young men were asked to perform a cursor travel task on a notebook computer using both 60- and 80-cm high table conditions. Analysis showed that the trackball mouse significantly decreased completion times. Participants selected a hand position farther from the table edge and larger elbow angle for the trackball mouse than for the built-in touch-pad pointing device. Participants' neck, thoracic, and arm angles, or splenius capitis, trapezius, deltoid, and erector spinae muscle activities were not significantly affected by the devices, but table height significantly affected participants' completion times, hand positions, and postural angles.
ERIC Educational Resources Information Center
Sun, Jerry Chih-Yuan; Martinez, Brandon; Seli, Helena
2014-01-01
This study examines how incorporating different electronic feedback devices (i.e., clickers versus web-based polling) may affect specific types of student engagement (i.e., behavioral, emotional, and cognitive engagement), whether students' self-efficacy for learning and performance may differ between courses that have integrated clickers and…
Current Radiation Issues for Programmable Elements and Devices
NASA Technical Reports Server (NTRS)
Katz, R.; Wang, J. J.; Koga, R.; LaBel, A.; McCollum, J.; Brown, R.; Reed, R. A.; Cronquist, B.; Crain, S.; Scott, T.;
1998-01-01
State of the an programmable devices are utilizing advanced processing technologies, non-standard circuit structures, and unique electrical elements in commercial-off-the-shelf (COTS)-based, high-performance devices. This paper will discuss that the above factors, coupled with the systems application environment, have a strong interplay that affect the radiation hardness of programmable devices and have resultant system impacts in (1) reliability of the unprogrammed, biased antifuse for heavy ions (rupture), (2) logic upset manifesting itself as clock upset, and (3) configuration upset. General radiation characteristics of advanced technologies are examined and manufacturers' modifications to their COTS-based and their impact on future programmable devices will be analyzed.
Study on light and thermal energy of illumination device for plant factory design
NASA Astrophysics Data System (ADS)
Yoshida, A.; Moriuchi, K.; Ueda, Y.; Kinoshita, S.
2018-01-01
To investigate the effect of illumination devices on the yield of crops cultivated in a plant factory, it is necessary to measure the actual cultivation environmental factors related to the plant growth and understand the distribution ratio of light and thermal energy to the electrical energy injected into the illumination device. Based on cultivation results, we found that light intensity greatly affected the growth of plant weight. Regarding the selection of illumination device, its spectral components also affected the morphological change. Lighting experiments using a high frequency (Hf) fluorescent lamp and a light emitting diode (LED) bulb were performed. A certain difference was found in the distribution ratio of light energy to electrical energy between Hf and LED. It was showed that by placing the safety equipment or internal circuits outside the cultivated site, the air conditioning load could be reduced.
Non-Invasive Tension Measurement Devices for Parachute Cordage
NASA Technical Reports Server (NTRS)
Litteken, Douglas A.; Daum, Jared S.
2016-01-01
The need for lightweight and non-intrusive tension measurements has arisen alongside the development of high-fidelity computer models of textile and fluid dynamics. In order to validate these computer models, data must be gathered in the operational environment without altering the design, construction, or performance of the test article. Current measurement device designs rely on severing a cord and breaking the load path to introduce a load cell. These load cells are very reliable, but introduce an area of high stiffness in the load path, directly affecting the structural response, adding excessive weight, and possibly altering the dynamics of the parachute during a test. To capture the required data for analysis validation without affecting the response of the system, non-invasive measurement devices have been developed and tested by NASA. These tension measurement devices offer minimal impact to the mass, form, fit, and function of the test article, while providing reliable, axial tension measurements for parachute cordage.
NASA Astrophysics Data System (ADS)
Kim, Kyo-Tae; Yun, Ryang-Young; Han, Moo-Jae; Heo, Ye-Ji; Song, Yong-Keun; Heo, Sung-Wook; Oh, Kyeong-Min; Park, Sung-Kwang
2017-10-01
Currently, in the radiation diagnosis field, mammography is used for the early detection of breast cancer. In addition, studies are being conducted on a grid to produce high-quality images. Although the grid ratio of the grid, which affects the scattering removal rate, must be increased to improve image quality, it increases the total exposure dose. While the use of automatic exposure control is recommended to minimize this problem, existing mammography equipment, unlike general radiography equipment, is mounted on the back of a detector. Therefore, the device is greatly affected by the detector and supporting device, and it is difficult to control the exposure dose. Accordingly, in this research, an integrated AEC-grid device that simultaneously performs AEC and grid functions was used to minimize the unnecessary exposure dose while removing scattering, thereby realizing superior image quality.
Theoretical considerations of soil retention. [dirtying of solar energy devices
NASA Technical Reports Server (NTRS)
Cuddihy, E. F.
1980-01-01
The performance of solar energy devices is adversely affected by surface soiling, and generally, the loss of performance increases with increases in the quantity of soil retained on their surfaces. To minimize performance losses caused by soiling, solar devices should not only be deployed in low soiling geographical areas, but employ surfaces or surfacing materials having low affinity for soil retention, maximum susceptibility to be naturally cleaned by wind, rain and snow, and to be readily cleanable by simple and inexpensive maintenance cleaning techniques. This article describes known and postulated mechanisms of soil retention on surfaces, and infers from these mechanisms that low soiling and easily cleanable surfaces should have low surface energy, and be hard, smooth, hydrophobic and chemically clean of sticky materials and water soluble salts.
The eye-tracking computer device for communication in amyotrophic lateral sclerosis.
Spataro, R; Ciriacono, M; Manno, C; La Bella, V
2014-07-01
To explore the effectiveness of communication and the variables affecting the eye-tracking computer system (ETCS) utilization in patients with late-stage amyotrophic lateral sclerosis (ALS). We performed a telephone survey on 30 patients with advanced non-demented ALS that were provisioned an ECTS device. Median age at interview was 55 years (IQR = 48-62), with a relatively high education (13 years, IQR = 8-13). A one-off interview was made and answers were later provided with the help of the caregiver. The interview included items about demographic and clinical variables affecting the daily ETCS utilization. The median time of ETCS device possession was 15 months (IQR = 9-20). The actual daily utilization was 300 min (IQR = 100-720), mainly for the communication with relatives/caregiver, internet surfing, e-mailing, and social networking. 23.3% of patients with ALS (n = 7) had a low daily ETCS utilization; most reported causes were eye-gaze tiredness and oculomotor dysfunction. Eye-tracking computer system is a valuable device for AAC in patients with ALS, and it can be operated with a good performance. The development of oculomotor impairment may limit its functional use. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
40 CFR 60.453 - Performance test and compliance provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
....45 Manual electrostatic spray 0.60 Flow coat 0.85 Dip coat 0.85 Nonrotational automatic electrostatic... applied (G) during the calendar month for each affected facility by the following equation: EC16NO91.038... affected facility that uses a capture system and a control device that destroys VOC's (e.g., incinerator...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Repins, Ingrid; Mansfield, Lorelle; Kanevce, Ana
Band-edge effects - including grading, electrostatic fluctuations, bandgap fluctuations, and band tails - affect chalcogenide device efficiency. These effects now require more careful consideration as efficiencies increase beyond 20%. Several aspects of the relationships between band-edge phenomena and device performance for NREL absorbers are examined. For Cu(In, Ga)Se2 devices, recent increases in diffusion length imply changes to the optimum bandgap profile. The origin, impact, and modification of electrostatic and bandgap fluctuations are also discussed. The application of the same principles to devices based on CdTe, kesterites, and emerging absorbers (Cu2SnS3, CuSbS2), considering differences in materials properties, is examined.
Electrothermal feedback in kinetic inductance detectors
NASA Astrophysics Data System (ADS)
Guruswamy, T.; Thomas, C. N.; Withington, S.; Goldie, D. J.
2017-06-01
In kinetic inductance detectors (KIDs) and other similar applications of superconducting microresonators, both the large and small-signal behaviour of the device may be affected by electrothermal feedback. Microwave power applied to read out the device is absorbed by and heats the superconductor quasiparticles, changing the superconductor conductivity and hence the readout power absorbed in a positive or negative feedback loop. In this work, we explore numerically the implications of an extensible theoretical model of a generic superconducting microresonator device for a typical KID, incorporating recent work on the power flow between superconductor quasiparticles and phonons. This model calculates the large-signal (changes in operating point) and small-signal behaviour of a device, allowing us to determine the effect of electrothermal feedback on device responsivity and noise characteristics under various operating conditions. We also investigate how thermally isolating the device from the bath, for example by designing the device on a membrane only connected to the bulk substrate by thin legs, affects device performance. We find that at a typical device operating point, positive electrothermal feedback reduces the effective thermal conductance from the superconductor quasiparticles to the bath, and so increases responsivity to signal (pair-breaking) power, increases noise from temperature fluctuations, and decreases the noise equivalent power (NEP). Similarly, increasing the thermal isolation of the device while keeping the quasiparticle temperature constant decreases the NEP, but also decreases the device response bandwidth.
Experimental Study of Lightweight Tracked Vehicle Performance on Dry Granular Materials
2013-09-12
agricultural tractor and found that the length of the ground contact area is the most important factor affecting tractive performance, while track...authors are grateful to Ce- cilia Cantu and to Meccanotecnica Riesi SRL for collaborating on designing and manufacturing the single track device
Optoelectronic device physics and technology of nitride semiconductors from the UV to the terahertz.
Moustakas, Theodore D; Paiella, Roberto
2017-10-01
This paper reviews the device physics and technology of optoelectronic devices based on semiconductors of the GaN family, operating in the spectral regions from deep UV to Terahertz. Such devices include LEDs, lasers, detectors, electroabsorption modulators and devices based on intersubband transitions in AlGaN quantum wells (QWs). After a brief history of the development of the field, we describe how the unique crystal structure, chemical bonding, and resulting spontaneous and piezoelectric polarizations in heterostructures affect the design, fabrication and performance of devices based on these materials. The heteroepitaxial growth and the formation and role of extended defects are addressed. The role of the chemical bonding in the formation of metallic contacts to this class of materials is also addressed. A detailed discussion is then presented on potential origins of the high performance of blue LEDs and poorer performance of green LEDs (green gap), as well as of the efficiency reduction of both blue and green LEDs at high injection current (efficiency droop). The relatively poor performance of deep-UV LEDs based on AlGaN alloys and methods to address the materials issues responsible are similarly addressed. Other devices whose state-of-the-art performance and materials-related issues are reviewed include violet-blue lasers, 'visible blind' and 'solar blind' detectors based on photoconductive and photovoltaic designs, and electroabsorption modulators based on bulk GaN or GaN/AlGaN QWs. Finally, we describe the basic physics of intersubband transitions in AlGaN QWs, and their applications to near-infrared and terahertz devices.
Optoelectronic device physics and technology of nitride semiconductors from the UV to the terahertz
NASA Astrophysics Data System (ADS)
Moustakas, Theodore D.; Paiella, Roberto
2017-10-01
This paper reviews the device physics and technology of optoelectronic devices based on semiconductors of the GaN family, operating in the spectral regions from deep UV to Terahertz. Such devices include LEDs, lasers, detectors, electroabsorption modulators and devices based on intersubband transitions in AlGaN quantum wells (QWs). After a brief history of the development of the field, we describe how the unique crystal structure, chemical bonding, and resulting spontaneous and piezoelectric polarizations in heterostructures affect the design, fabrication and performance of devices based on these materials. The heteroepitaxial growth and the formation and role of extended defects are addressed. The role of the chemical bonding in the formation of metallic contacts to this class of materials is also addressed. A detailed discussion is then presented on potential origins of the high performance of blue LEDs and poorer performance of green LEDs (green gap), as well as of the efficiency reduction of both blue and green LEDs at high injection current (efficiency droop). The relatively poor performance of deep-UV LEDs based on AlGaN alloys and methods to address the materials issues responsible are similarly addressed. Other devices whose state-of-the-art performance and materials-related issues are reviewed include violet-blue lasers, ‘visible blind’ and ‘solar blind’ detectors based on photoconductive and photovoltaic designs, and electroabsorption modulators based on bulk GaN or GaN/AlGaN QWs. Finally, we describe the basic physics of intersubband transitions in AlGaN QWs, and their applications to near-infrared and terahertz devices.
NASA Astrophysics Data System (ADS)
Wegrzyński, Wojciech; Krajewski, Grzegorz; Kimbar, Grzegorz
2018-01-01
This paper is a proposal of a new device that may be used as a component of natural smoke ventilation systems - an external aerodynamic baffle used to limit the wind effect at the most adverse angle. Natural ventilation is not only affected by the external wind, but also dependent on the angle of wind attack. It has been proven, that at angles between 45° to 60° the performance of such device is the lowest. This is the reason why additional device is proposed - external baffle that could hypothetically increase the performance at chosen angles. The purpose of this paper is to explore this idea by numerical modelling of such external elements on a validated natural ventilator model, with use of ANSYS® Fluent® CFD model.
NASA Astrophysics Data System (ADS)
Liu, Liang-kui; Shi, Cheng; Zhang, Yi-bo; Sun, Lei
2017-04-01
A tri gate Ge-based tunneling field-effect transistor (TFET) has been numerically studied with technology computer aided design (TCAD) tools. Dopant segregated Schottky source/drain is applied to the device structure design (DS-TFET). The characteristics of the DS-TFET are compared and analyzed comprehensively. It is found that the performance of n-channel tri gate DS-TFET with a positive bias is insensitive to the dopant concentration and barrier height at n-type drain, and that the dopant concentration and barrier height at a p-type source considerably affect the device performance. The domination of electron current in the entire BTBT current of this device accounts for this phenomenon and the tri-gate DS-TFET is proved to have a higher performance than its dual-gate counterpart.
NASA Astrophysics Data System (ADS)
Chattopadhyay, Avik; Mallik, Abhijit; Omura, Yasuhisa
2015-06-01
A gate-on-germanium source (GoGeS) tunnel field-effect transistor (TFET) shows great promise for low-power (sub-0.5 V) applications. A detailed investigation, with the help of a numerical device simulator, on the effects of variation in different structural parameters of a GoGeS TFET on its electrical performance is reported in this paper. Structural parameters such as κ-value of the gate dielectric, length and κ-value of the spacer, and doping concentrations of both the substrate and source are considered. A low-κ symmetric spacer and a high-κ gate dielectric are found to yield better device performance. The substrate doping influences only the p-i-n leakage floor. The source doping is found to significantly affect performance parameters such as OFF-state current, ON-state current and subthreshold swing, in addition to a threshold voltage shift. Results of the investigation on the gate length scaling of such devices are also reported in this paper.
Self-Heating Effects In Polysilicon Source Gated Transistors
Sporea, R. A.; Burridge, T.; Silva, S. R. P.
2015-01-01
Source-gated transistors (SGTs) are thin-film devices which rely on a potential barrier at the source to achieve high gain, tolerance to fabrication variability, and low series voltage drop, relevant to a multitude of energy-efficient, large-area, cost effective applications. The current through the reverse-biased source barrier has a potentially high positive temperature coefficient, which may lead to undesirable thermal runaway effects and even device failure through self-heating. Using numerical simulations we show that, even in highly thermally-confined scenarios and at high current levels, self-heating is insufficient to compromise device integrity. Performance is minimally affected through a modest increase in output conductance, which may limit the maximum attainable gain. Measurements on polysilicon devices confirm the simulated results, with even smaller penalties in performance, largely due to improved heat dissipation through metal contacts. We conclude that SGTs can be reliably used for high gain, power efficient analog and digital circuits without significant performance impact due to self-heating. This further demonstrates the robustness of SGTs. PMID:26351099
Pippi, Roberto
2013-01-01
The primary aim of the present study was to validate the effectiveness of a personalized device able to guide periodontal probing in evaluation of second molar periodontal healing after adjacent third molar surgical extraction. Secondarily, the study analyzed if any patient and tooth related factors affected the second molar periodontal healing as well as if they were able to affect the periodontal probing depth performed with or without the personalized device. Thirty-five lower second molars were evaluated after extraction of the adjacent third molar. Pre-operative as well as 3 and 12 month post-operative probing depths of the distal surface of the second molar were evaluated. All measurements were taken by two different methods: standard two-point and four-point probing using a personalized onlay-type guide. Periapical radiographs were also evaluated. The Pearson product moment and the general linear model with backward stepwise procedure were used for inferential statistics. The mean 12-month post-operative probing depth/mean pre-operative probing depth ratio obtained with the guided probing method showed a highly significant effect on the 12-month radiographic post-operative/pre-operative radiographic measure ratio. None of the examined patient- or tooth-related factors showed a significant effect on pre-operative/12-month post-operative radiographic measure ratio. The use of the proposed personalized device seems to provide a more reliable estimate of second molar periodontal healing after adjacent third molar surgical extraction. No patient-or tooth-related factors seem to be able to affect either second molar periodontal healing or probing depth measures obtained with or without the personalized device in individuals younger than 25 years old. It can be therefore recommended that lower third molar surgical extraction be performed in young adults.
The efficiency of gravity distribution devices for on-site wastewater treatment systems.
Patel, T; O'Luanaigh, N; Gill, L W
2008-01-01
A detailed analysis of different types of gravity distribution devices, designed to split on-site wastewater effluent equally between percolation trenches, has been carried out both in the laboratory and also in the field under realistic loading conditions. Five different types of distribution device have been compared: a V-notch distribution box, stilling chamber box, T-splitters with and without baffles and tipping bucket device. The trials carried out in the laboratory with clean water showed that flow distribution for all devices was sensitive to both the off-level installation angles and variable flow rates, with the most stable performance achieved using the T-splitters with baffles and tipping bucket devices. In parallel to this, the on-site flow regime experienced at two sites was continuously monitored using a tipping bucket and data-logger over eighteen month periods, finding that the most common flow rates at the distribution unit were in the range of 0.1-2.5 L/min. The on-site performance of these devices receiving both septic tank and secondary treated effluent showed that significant solid deposition and biofilm development had severely affected the equal distribution between the trenches, hence highlighting the need for regular maintenance to ensure efficient performance over time after installation. IWA Publishing 2008.
Baruselli, P S; Reis, E L; Marques, M O; Nasser, L F; Bó, G A
2004-07-01
Most of the world's bovine herd is found in tropical regions. Bos indicus predominates, due to their adaptation to the climate and management conditions. Anestrous is the main factor that negatively affects reproductive performance of animals bred in these regions of the globe. Several factors affect postpartum anestrous, including suckling and maternal-offspring bond, and pre- and postpartum nutritional status. The short duration of estrus and the tendency to show estrus during the night, greatly affect the efficiency of artificial insemination (AI) programs in B. indicus cattle managed in tropical areas. Several restricted suckling or weaning procedures (temporary or permanent), and hormonal treatments have been used to induce ovulation and cyclicity in postpartum cows. Most hormonal treatments are based on progesterone/progestogen (P4) releasing devices associated with estradiol benzoate (EB), or a combination of GnRH/PGF(2alpha)/GnRH (Ovsynch). Treatments with GnRH/PGF(2alpha)/GnRH has presented inconsistent results, probably due to the variable number of cows in anestrous. Treatments using P4 devices and EB have resulted in apparently more consistent results than Ovsynch programs in B. indicus cattle; however, pregnancy rates are low in herds presenting high anestrous rates and moderate to low body condition. The addition of an eCG treatment at the time of device removal, which increased plasma progesterone concentrations and pregnancy rates in anestrous postpartum suckled B. indicus cows, may be useful to improve reproductive performance of beef cattle in tropical climates.
Jahanmir, Said; Hunsberger, Andrew Z; Heshmat, Hooshang; Tomaszewski, Michael J; Walton, James F; Weiss, William J; Lukic, Branka; Pae, William E; Zapanta, Conrad M; Khalapyan, Tigran Z
2008-05-01
The MiTiHeart (MiTiHeart Corporation, Gaithersburg, MD, USA) left ventricular assist device (LVAD), a third-generation blood pump, is being developed for destination therapy for adult heart failure patients of small to medium frame that are not being served by present pulsatile devices. The pump design is based on a novel, patented, hybrid passive/active magnetic bearing system with backup hydrodynamic thrust bearing and exhibits low power loss, low vibration, and low hemolysis. Performance of the titanium alloy prototype was evaluated in a series of in vitro tests with blood analogue to map out the performance envelop of the pump. The LVAD prototype was implanted in a calf animal model, and the in vivo pump performance was evaluated. The animal's native heart imparted a strong pulsatility to the flow rate. These tests confirmed the efficacy of the MiTiHeart LVAD design and confirmed that the pulsatility does not adversely affect the pump performance.
Reading performance with large fonts on high-resolution displays
NASA Astrophysics Data System (ADS)
Powers, Maureen K.; Larimer, James O.; Gille, Jennifer; Liu, Hsien-Chang
2004-06-01
Reading is a fundamental task and skill in many environments including business, education, and the home. Today, reading often occurs on electronic displays in addition to traditional hard copy media such as books and magazines, presenting issues of legibility and other factors that can affect human performance [1]. In fact, the transition to soft copy media for text images is often met with worker complaints about their vision and comfort while reading [2-6]. Careful comparative evaluations of reading performance across hard and soft copy device types are rare, even though they are clearly important given the rapid and substantial improvements in soft copy devices available in the marketplace over the last 5 years. To begin to fill this evaluation gap, we compared reading performance on three different soft copy devices and traditional paper. This study does not investigate comfort factors such as display location, seating comfort, and more general issues of lighting, rather we focus instead on a narrow examination of reading performance differences across display types when font sizes are large.
NASA Astrophysics Data System (ADS)
Shin, Jong-Yeol; Kim, Tae Wan; Kim, Gwi-Yeol; Lee, Su-Min; Shrestha, Bhanu; Hong, Jin-Woong
2016-05-01
Performance of organic light-emitting diodes was investigated depending on the electron-injection materials of metal carbonates (Li2CO3 and Cs2CO3 ); and number of layers. In order to improve the device efficiency, two types of devices were manufactured by using the hole-injection material (Teflon-amorphous fluoropolymer -AF) and electron-injection materials; one is a two-layer reference device ( ITO/Teflon-AF/Alq3/Al ) and the other is a three-layer device (ITO/Teflon-AF/Alq3/metal carbonate/Al). From the results of the efficiency for the devices with hole-injection layer and electron-injection layer, it was found that the electron-injection layer affects the electrical properties of the device more than the hole-injection layer. The external-quantum efficiency for the three-layer device with Li2CO3 and Cs2CO3 layer is improved by approximately six and eight times, respectively, compared with that of the two-layer reference device. It is thought that a use of electron-injection layer increases recombination rate of charge carriers by the active injection of electrons and the blocking of holes.
NASA Technical Reports Server (NTRS)
Palsson, Olafur S. (Inventor); Harris, Randall L., Sr. (Inventor); Pope, Alan T. (Inventor)
2002-01-01
Apparatus and methods for modulating the control authority (i.e., control function) of a computer simulation or game input device (e.g., joystick, button control) using physiological information so as to affect the user's ability to impact or control the simulation or game with the input device. One aspect is to use the present invention, along with a computer simulation or game, to affect physiological state or physiological self-regulation according to some programmed criterion (e.g., increase, decrease, or maintain) in order to perform better at the game task. When the affected physiological state or physiological self-regulation is the target of self-regulation or biofeedback training, the simulation or game play reinforces therapeutic changes in the physiological signal(s).
Vapor-fed microfluidic hydrogen generator.
Modestino, M A; Dumortier, M; Hosseini Hashemi, S M; Haussener, S; Moser, C; Psaltis, D
2015-05-21
Water-splitting devices that operate with humid air feeds are an attractive alternative for hydrogen production as the required water input can be obtained directly from ambient air. This article presents a novel proof-of-concept microfluidic platform that makes use of polymeric ion conductor (Nafion®) thin films to absorb water from air and performs the electrochemical water-splitting process. Modelling and experimental tools are used to demonstrate that these microstructured devices can achieve the delicate balance between water, gas, and ionic transport processes required for vapor-fed devices to operate continuously and at steady state, at current densities above 3 mA cm(-2). The results presented here show that factors such as the thickness of the Nafion films covering the electrodes, convection of air streams, and water content of the ionomer can significantly affect the device performance. The insights presented in this work provide important guidelines for the material requirements and device designs that can be used to create practical electrochemical hydrogen generators that work directly under ambient air.
Hydrodynamics-induced variability in the USP apparatus II dissolution test.
Baxter, Jennifer L; Kukura, Joseph; Muzzio, Fernando J
2005-03-23
The USP tablet dissolution test is an analytical tool used for the verification of drug release processes and formulation selection within the pharmaceutical industry. Given the strong impact of this test, it is surprising that operating conditions and testing devices have been selected empirically. In fact, the flow phenomena in the USP test have received little attention in the past. An examination of the hydrodynamics in the USP apparatus II shows that the device is highly vulnerable to mixing problems that can affect testing performance and consistency. Experimental and computational techniques reveal that the flow field within the device is not uniform, and dissolution results can vary dramatically with the position of the tablet within the vessel. Specifically, computations predict sharp variations in the shear along the bottom of the vessel where the tablet is most likely to settle. Experiments in which the tablet location was carefully controlled reveal that the variation of shear within the testing device can affect the measured dissolution rate.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-19
... performing the technical analysis, management assessment, and program evaluation tasks required to address... premarket reviews that meet regulatory review standards. 2. Analysis of elements of the review process... process. This includes analysis of root causes for inefficiencies that may affect review performance and...
NASA Astrophysics Data System (ADS)
Nemec, Patrik; Malcho, Milan
2018-06-01
This work deal with experimental measurement and calculation cooling efficiency of the cooling device working with a heat pipe technology. The referred device in the article is cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description, working principle and construction of cooling device. The main factor affected the dissipation of high heat flux from electronic elements through the cooling device to the surrounding is condenser construction, its capacity and option of heat removal. Experimental part describe the measuring method cooling efficiency of the cooling device depending on ambient temperature in range -20 to 40°C and at heat load of electronic components 750 W. Measured results are compared with results calculation based on physical phenomena of boiling, condensation and natural convection heat transfer.
Meshinchi, Soheil; Hunger, Stephen P.; Aplenc, Richard; Adamson, Peter C.; Jessup, J. Milburn
2012-01-01
The FDA is now exerting its regulatory authority over molecular diagnostics and their assays used for medical-decision making in clinical trials by performing pre-Investigational Device Exemption (IDE) reviews in all phases of clinical trials. This review assesses the analytical performance of the assay for the diagnostic and considers how that performance affects the diagnostic and the patient and their risks and benefits from treatment. This manuscript reviews the process of the first review that was performed on a new Children's Oncology Group (COG) Phase III trial in Acute Myelogenous Leukemia. The lessons learned and recommendations for how to prepare for and incorporate this new level of regulatory review into the protocol development process are presented. PMID:22422407
Radiation Effects on Current Field Programmable Technologies
NASA Technical Reports Server (NTRS)
Katz, R.; LaBel, K.; Wang, J. J.; Cronquist, B.; Koga, R.; Penzin, S.; Swift, G.
1997-01-01
Manufacturers of field programmable gate arrays (FPGAS) take different technological and architectural approaches that directly affect radiation performance. Similar y technological and architectural features are used in related technologies such as programmable substrates and quick-turn application specific integrated circuits (ASICs). After analyzing current technologies and architectures and their radiation-effects implications, this paper includes extensive test data quantifying various devices total dose and single event susceptibilities, including performance degradation effects and temporary or permanent re-configuration faults. Test results will concentrate on recent technologies being used in space flight electronic systems and those being developed for use in the near term. This paper will provide the first extensive study of various configuration memories used in programmable devices. Radiation performance limits and their impacts will be discussed for each design. In addition, the interplay between device scaling, process, bias voltage, design, and architecture will be explored. Lastly, areas of ongoing research will be discussed.
Study of the properties of new SPM detectors
NASA Astrophysics Data System (ADS)
Stewart, A. G.; Greene-O'Sullivan, E.; Herbert, D. J.; Saveliev, V.; Quinlan, F.; Wall, L.; Hughes, P. J.; Mathewson, A.; Jackson, J. C.
2006-02-01
The operation and performance of multi-pixel, Geiger-mode APD structures referred to as Silicon Photomultiplier (SPM) are reported. The SPM is a solid state device that has emerged over the last decade as a promising alternative to vacuum PMTs. This is due to their comparable performance in addition to their lower bias operation and power consumption, insensitivity to magnetic fields and ambient light, smaller size and ruggedness. Applications for these detectors are numerous and include life sciences, nuclear medicine, particle physics, microscopy and general instrumentation. With SPM devices, many geometrical and device parameters can be adjusted to optimize their performance for a particular application. In this paper, Monte Carlo simulations and experimental results for 1mm2 SPM structures are reported. In addition, trade-offs involved in optimizing the SPM in terms of the number and size of pixels for a given light intensity, and its affect on the dynamic range are discussed.
NASA Astrophysics Data System (ADS)
Liu, Shengqiang; Zhao, Juan; Huang, Jiang; Yu, Junsheng
2016-12-01
Organic light-emitting devices (OLEDs) with three different exciton adjusting interlayers (EALs), which are inserted between two complementary blue and yellow emitting layers, are fabricated to demonstrate the relationship between the EAL and device performance. The results show that the variations of type and thickness of EAL have different adjusting capability and distribution control on excitons. However, we also find that the reverse Dexter transfer of triplet exciton from the light-emitting layer to the EAL is an energy loss path, which detrimentally affects electroluminescent (EL) spectral performance and device efficiency in different EAL-based devices. Based on exciton distribution and integration, an estimation of exciton reverse transfer is developed through a triplet energy level barrier to simulate the exciton behavior. Meanwhile, the estimation results also demonstrate the relationship between the EAL and device efficiency by a parameter of exciton reverse transfer probability. The estimation of exciton reverse transfer discloses a crucial role of the EALs in the interlayer-based OLEDs to achieve variable EL spectra and high efficiency.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Repins, Ingrid; Mansfield, Lorelle; Kanevce, Ana
Band-edge effects -- including grading, electrostatic fluctuations, bandgap fluctuations, and band tails -- affect chalcogenide device efficiency. These effects now require more careful consideration as efficiencies increase beyond 20%. Several aspects of the relationships between band-edge phenomena and device performance for NREL absorbers are examined. For Cu(In,Ga)Se2 devices, recent increases in diffusion length imply changes to optimum bandgap profile. The origin, impact, and modification of electrostatic and bandgap fluctuations are also discussed. The application of the same principles to devices based on CdTe, kesterites, and emerging absorbers (Cu2SnS3, CuSbS2), considering differences in materials properties and defect formation energies, is examined.
Müller, Corsin A.; Riemer, Stefanie; Range, Friederike; Huber, Ludwig
2014-01-01
Visible and invisible displacement tasks have been used widely for comparative studies of animals’ understanding of object permanence, with evidence accumulating that some species can solve invisible displacement tasks and thus reach Piagetian stage 6 of object permanence. In contrast, dogs appear to rely on associative cues, such as the location of the displacement device, during invisible displacement tasks. It remains unclear, however, whether dogs, and other species that failed in invisible displacement tasks, do so due to their inability to form a mental representation of the target object, or simply due to the involvement of a more salient but potentially misleading associative cue, the displacement device. Here we show that the use of a displacement device impairs the performance of dogs also in visible displacement tasks: their search accuracy was significantly lower when a visible displacement was performed with a displacement device, and only two of initially 42 dogs passed the sham-baiting control conditions. The negative influence of the displacement device in visible displacement tasks may be explained by strong associative cues overriding explicit information about the target object’s location, reminiscent of an overshadowing effect, and/or object individuation errors as the target object is placed within the displacement device and moves along a spatiotemporally identical trajectory. Our data suggest that a comprehensive appraisal of a species’ performance in object permanence tasks should include visible displacement tasks with the same displacement device used in invisible displacements, which typically has not been done in the past. PMID:24611641
Müller, Corsin A; Riemer, Stefanie; Range, Friederike; Huber, Ludwig
2014-08-01
Visible and invisible displacement tasks have been used widely for comparative studies of animals' understanding of object permanence, with evidence accumulating that some species can solve invisible displacement tasks and, thus, reach Piagetian stage 6 of object permanence. In contrast, dogs appear to rely on associative cues, such as the location of the displacement device, during invisible displacement tasks. It remains unclear, however, whether dogs, and other species that failed in invisible displacement tasks, do so because of their inability to form a mental representation of the target object, or simply because of the involvement of a more salient but potentially misleading associative cue, the displacement device. Here we show that the use of a displacement device impairs the performance of dogs also in visible displacement tasks: their search accuracy was significantly lower when a visible displacement was performed with a displacement device, and only two of initially 42 dogs passed the sham-baiting control conditions. The negative influence of the displacement device in visible displacement tasks may be explained by strong associative cues overriding explicit information about the target object's location, reminiscent of an overshadowing effect, and/or object individuation errors as the target object is placed within the displacement device and moves along a spatiotemporally identical trajectory. Our data suggest that a comprehensive appraisal of a species' performance in object permanence tasks should include visible displacement tasks with the same displacement device used in invisible displacements, which typically has not been done in the past.
Li, Jiangsheng; Duan, Chenghao; Wang, Ning; Zhao, Chengjie; Han, Wei; Jiang, Li; Wang, Jizheng; Zhao, Yingjie; Huang, Changshui; Jiu, Tonggang
2018-05-08
The molecular structure of cathode interface modification materials can affect the surface morphology of the active layer and key electron transfer processes occurring at the interface of polymer solar cells in inverted structures mostly due to the change of molecular configuration. To investigate the effects of spatial configuration of the cathode interfacial modification layer on polymer solar cells device performances, we introduced two novel organic ionic salts (linear NS2 and three-dimensional (3D) NS4) combined with the ZnO film to fabricate highly efficient inverted solar cells. Both organic ionic salts successfully decreased the surface traps of the ZnO film and made its work function more compatible. Especially NS4 in three-dimensional configuration increased the electron mobility and extraction efficiency of the interfacial film, leading to a significant improvement of device performance. Power conversion efficiency (PCE) of 10.09% based on NS4 was achieved. Moreover, 3D interfacial modification could retain about 92% of its initial PCE over 160 days. It is proposed that 3D interfacial modification retards the element penetration-induced degradation without impeding the electron transfer from the active layer to the ZnO film, which significantly improves device stability. This indicates that inserting three-dimensional organic ionic salt is an efficient strategy to enhance device performance.
Polli, Filippo Maria; Trungu, Sokol; Miscusi, Massimo; Forcato, Stefano; Visocchi, Massimiliano; Raco, Antonino
2017-01-01
Atlantoaxial joint distraction has been advocated for the decompression of the brain stem in patients affected by basilar invagination, avoiding direct transoral decompression. This technique requires C2 ganglion resection and it is often impossible to perform due to the peculiar bony anatomy. We describe a cadaveric anatomical study supporting the feasibility of C1-C2 distraction performed with an expandable device, allowing easier insertion of the tool and preservation of the C2 nerve root. In five adult cadaveric specimens, posterior atlantoaxial surgical exposure was performed and an expandable system was inserted within the C1-C2 joint. The expansion of the device, leading to active distraction of the joint space, together with all the surgical steps of the technique was recorded with anatomical pictures and the final results were checked with a computed tomography (CT) scan. Insertion of the device was easily performed in all cases without anatomical conflict with the C2 ganglion; CT scans confirmed the distraction of the C1-C2 joint. This cadaveric anatomical study confirms the feasibility of the introduction of an expandable and flexible device within the C1-C2 joint, allowing it's distraction and preservation of the C2 ganglion.
Adinolfi, Valerio; Peng, Wei; Walters, Grant; Bakr, Osman M; Sargent, Edward H
2018-01-01
Organometal halide perovskites are under intense study for use in optoelectronics. Methylammonium and formamidinium lead iodide show impressive performance as photovoltaic materials; a premise that has spurred investigations into light-emitting devices and photodetectors. Herein, the optical and electrical material properties of organometal halide perovskites are reviewed. An overview is given on how the material composition and morphology are tied to these properties, and how these properties ultimately affect device performance. Material attributes and techniques used to estimate them are analyzed for different perovskite materials, with a particular focus on the bandgap, mobility, diffusion length, carrier lifetime, and trap-state density. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Designing and testing a tool for evaluating electronic flight bags
DOT National Transportation Integrated Search
2004-09-29
The Federal Aviation Administration (FAA), system designers, and customers all recognize that Electronic Flight Bags (EFBs) are sophisticated devices whose use could affect pilot performance. As a result, human factors issues have received considerab...
Progress on Electronic and Optoelectronic Devices of 2D Layered Semiconducting Materials.
Wang, Feng; Wang, Zhenxing; Jiang, Chao; Yin, Lei; Cheng, Ruiqing; Zhan, Xueying; Xu, Kai; Wang, Fengmei; Zhang, Yu; He, Jun
2017-09-01
2D layered semiconducting materials (2DLSMs) represent the thinnest semiconductors, holding many novel properties, such as the absence of surface dangling bonds, sizable band gaps, high flexibility, and ability of artificial assembly. With the prospect of bringing revolutionary opportunities for electronic and optoelectronic applications, 2DLSMs have prospered over the past twelve years. From materials preparation and property exploration to device applications, 2DLSMs have been extensively investigated and have achieved great progress. However, there are still great challenges for high-performance devices. In this review, we provide a brief overview on the recent breakthroughs in device optimization based on 2DLSMs, particularly focussing on three aspects: device configurations, basic properties of channel materials, and heterostructures. The effects from device configurations, i.e., electrical contacts, dielectric layers, channel length, and substrates, are discussed. After that, the affect of the basic properties of 2DLSMs on device performance is summarized, including crystal defects, crystal symmetry, doping, and thickness. Finally, we focus on heterostructures based on 2DLSMs. Through this review, we try to provide a guide to improve electronic and optoelectronic devices of 2DLSMs for achieving practical device applications in the future. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
The Effects of the Removal of Electronic Devices for 48 Hours on Sleep in Elite Judo Athletes.
Dunican, Ian C; Martin, David T; Halson, Shona L; Reale, Reid J; Dawson, Brian T; Caldwell, John A; Jones, Maddison J; Eastwood, Peter R
2017-10-01
This study examined the effects of evening use of electronic devices (i.e., smartphones, etc.) on sleep quality and next-day athletic and cognitive performance in elite judo athletes. Over 6 consecutive days and nights, 23 elite Australian judo athletes were monitored while attending a camp at the Australian Institute of Sport (AIS). In 14 athletes, all electronic devices were removed on days 3 and 4 (i.e., for 48 hours: the "device-restricted group"), whereas 9 were permitted to use their devices throughout the camp (the "control group"). All athletes wore an activity monitor (Readiband) continuously to provide measures of sleep quantity and quality. Other self-reported (diary) measures included time in bed, electronic device use, and rate of perceived exertion during training periods. Cognitive performance (Cogstate) and physical performance (single leg triple hop test) were also measured. When considering night 2 as a "baseline" for each group, removal of electronic devices on nights 3 and 4 (device-restricted group) resulted in no significant differences in any sleep-related measure between the groups. When comparing actigraphy-based measures of sleep to subjective measures, all athletes significantly overestimated sleep duration by 58 ± 85 minutes (p = 0.001) per night and underestimated time of sleep onset by 37 ± 72 minutes (p = 0.001) per night. No differences in physical or cognitive function were observed between the groups. This study has shown that the removal of electronic devices for a period of two nights (48 hours) during a judo camp does not affect sleep quality or quantity or influence athletic or cognitive performance.
An Investigation of the Performance of Various Reaction Control Devices
NASA Technical Reports Server (NTRS)
Hunter, Paul A.
1959-01-01
An investigation of a small-scale reaction control devices in still air with both subsonic and supersonic internal flows has shown that lateral forces approaching 70 percent of the resultant force of the undeflected jet can be obtained. These results were obtained with a tilted extension at a deflection of 40 deg. The tests of tilted extensions indicated an optimum length-to-diameter ratio of approximately 0.75 to 1.00, dependent upon the deflection angle. For the two geometric types of spoiler tabs tested, blockage-area ratio appears to be the only variable affecting the lateral force developed. Usable values of lateral force were developed by the full-eyelid type of device with reasonably small losses in the thrust and weight flow. Somewhat larger values of lateral force were developed by injecting a secondary flow normal to the primary jet, but for conditions of these tests the losses in thrust and weight flow were large. Relatively good agreement with other investigations was obtained for several of the devices. The agreement of the present results with those of an investigation made with larger-scale equipment indicates that Reynolds number may not be critical for these tests. In as much as the effects of external flow could influence the performance and other factors affecting the choice of a reaction control for a specific use, it would appear desirable to make further tests of the devices described in this report in the presence of external flow.
1972-12-01
include filtering devices, venturi scrubbers , and electrostatic precipitators. These have been evaluated as unsatisfactory from considerations of...Early studies of pollution abatement systems have resulted in the selection and development of a nucleation scrubber [Ref. 47]. Other devices analyzed...the venturi system is its inability to operate efficiently over greater than a 10 percent interval away from its design point, which is an
Designing a tool to assess the usability of electronic flight bags (EFBs)
DOT National Transportation Integrated Search
2004-09-01
The Federal Aviation Administration (FAA), system designers, and customers all recognize that Electronic Flight Bags (EFBs) are sophisticated devices whose use could affect pilot performance. As a result, human factors issues have received considerab...
NASA Astrophysics Data System (ADS)
Kong, Weijing; Wan, Yuhang; Du, Kun; Zhao, Wenhui; Wang, Shuang; Zheng, Zheng
2016-11-01
The reflected intensity change of the Bloch-surface-wave (BSW) resonance influenced by the loss of a truncated onedimensional photonic crystal structure is numerically analyzed and studied in order to enhance the sensitivity of the Bloch-surface-wave-based sensors. The finite truncated one-dimensional photonic crystal structure is designed to be able to excite BSW mode for water (n=1.33) as the external medium and for p-polarized plane wave incident light. The intensity interrogation scheme which can be operated on a typical Kretschmann prism-coupling configuration by measuring the reflected intensity change of the resonance dip is investigated to optimize the sensitivity. A figure of merit (FOM) is introduced to measure the performance of the one-dimensional photonic crystal multilayer structure under the scheme. The detection sensitivities are calculated under different device parameters with a refractive index change corresponding to different solutions of glycerol in de-ionized (DI)-water. The results show that the intensity sensitivity curve varies similarly with the FOM curve and the sensitivity of the Bloch-surface-wave sensor is greatly affected by the device loss, where an optimized loss value can be got. For the low-loss BSW devices, the intensity interrogation sensing sensitivity may drop sharply from the optimal value. On the other hand, the performance of the detection scheme is less affected by the higher device loss. This observation is in accordance with BSW experimental sensing demonstrations as well. The results obtained could be useful for improving the performance of the Bloch-surface-wave sensors for the investigated sensing scheme.
Research and development of a heat-pump water heater. Volume 2. R and D task reports
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dunning, R.L.; Amthor, F.R.; Doyle, E.J.
1978-08-01
The heat pump water heater is a device that works much like a window air conditioner except that heat from the home is pumped into a water tank rather than to the outdoors. The objective established for the device is to operate with a Coefficient of Performance (COP) of 3 or, an input of one unit of electric energy would create three units of heat energy in the form of hot water. With such a COP, the device would use only one-third the energy and at one-third the cost of a standard resistance water heater. This Volume 2 contains themore » final reports of the three major tasks performed in Phase I. In Task 2, a market study identifies the future market and selects an initial target market and channel of distribution, all based on an analysis of the parameters affecting feasibility of the device and the factors that will affect its market acceptance. In the Task 3 report, the results of a design and test program to arrive at final designs of heat pumps for both new water heaters and for retrofitting existing water heaters are presented. In the Task 4 report, a plan for an extensive field demonstration involving use in actual homes is presented. Volume 1 contains a final summary report of the information in Volume 2.« less
Polymer-based doping control for performance enhancement of wet-processed short-channel CNTFETs
NASA Astrophysics Data System (ADS)
Hartmann, Martin; Schubel, René; Claus, Martin; Jordan, Rainer; Schulz, Stefan E.; Hermann, Sascha
2018-01-01
The electrical transport properties of short-channel transistors based on single-walled carbon nanotubes (CNT) are significantly affected by bundling along with solution processing. We report that especially high off currents of CNT transistors are not only related to the incorporation of metallic CNTs but also to the incorporation of CNT bundles. By applying device passivation with poly(4-vinylpyridine), the impact of CNT bundling on the device performance can be strongly reduced due to increased gate efficiency as well as reduced oxygen and water-induced p-type doping, boosting essential field-effect transistor performance parameters by several orders of magnitude. Moreover, this passivation approach allows the hysteresis and threshold voltage of CNT transistors to be tuned.
The optimization of design parameters for surge relief valve for pipeline systems
NASA Astrophysics Data System (ADS)
Kim, Hyunjun; Hur, Jisung; Kim, Sanghyun
2017-06-01
Surge is an abnormal pressure which induced by rapid changes of flow rate in pipeline systems. In order to protect pipeline system from the surge pressure, various hydraulic devices have been developed. Surge-relief valve(SRV) is one of the widely applied devices to control surge due to its feasibility in application, efficiency and cost-effectiveness. SRV is designed to automatically open under abnormal pressure and discharge the flow and makes pressure of the system drop to the allowable level. The performance of the SRV is influenced by hydraulics. According to previous studies, there are several affecting factors which determine performance of the PRV such as design parameters (e.g. size of the valve), system parameters (e.g. number of the valves and location of the valve), and operation parameters (e.g. set point and operation time). Therefore, the systematic consideration for factors affecting performance of SRV is required for the proper installation of SRV in the system. In this study, methodology for finding optimum parameters of the SRV is explored through the integration of Genetic Algorithm(GA) into surge analysis.
NASA Astrophysics Data System (ADS)
Liang, Xiaoci; Wang, Chengcai; Liang, Jun; Liu, Chuan; Pei, Yanli
2017-09-01
The oxygen related defects in the solution combustion-processed InZnO vitally affect the field-effect mobility and on-off characteristics in thin film transistors (TFTs). We use photoelectron spectroscopy to reveal that these defects can be well controlled by adjusting the atmosphere and flow rate during the combustion reaction, but are hardly affected by further post-annealing after the reaction. In device performance, the threshold voltage of the InZnO-TFTs was regulated in a wide range from 3.5 V to 11.0 V. To compromise the high field-effect mobility and good subthreshold properties, we fabricate the TFTs with double active layers of InZnO to achieve vertical gradience in defect distribution. The resulting TFT exhibits much higher field-effect mobility as 17.5 cm2 · V-1 · s-1, a low reversed sub-threshold slope as 0.35 V/decade, and a high on-off ratio as 107. The presented understandings and methods on defect engineering are efficient in improving the device performance of TFTs made from the combustion reaction process.
Pippi, Roberto
2013-01-01
Summary Aim The primary aim of the present study was to validate the effectiveness of a personalized device able to guide periodontal probing in evaluation of second molar periodontal healing after adjacent third molar surgical extraction. Secondarily, the study analyzed if any patient and tooth related factors affected the second molar periodontal healing as well as if they were able to affect the periodontal probing depth performed with or without the personalized device. Materials and methods Thirty-five lower second molars were evaluated after extraction of the adjacent third molar. Pre-operative as well as 3 and 12 month post-operative probing depths of the distal surface of the second molar were evaluated. All measurements were taken by two different methods: standard two-point and four-point probing using a personalized onlay-type guide. Periapical radiographs were also evaluated. The Pearson product moment and the general linear model with backward stepwise procedure were used for inferential statistics. Results The mean 12-month post-operative probing depth/mean pre-operative probing depth ratio obtained with the guided probing method showed a highly significant effect on the 12-month radiographic post-operative/pre-operative radiographic measure ratio. None of the examined patient- or tooth-related factors showed a significant effect on pre-operative/12-month post-operative radiographic measure ratio. Conclusions The use of the proposed personalized device seems to provide a more reliable estimate of second molar periodontal healing after adjacent third molar surgical extraction. No patient-or tooth-related factors seem to be able to affect either second molar periodontal healing or probing depth measures obtained with or without the personalized device in individuals younger than 25 years old. It can be therefore recommended that lower third molar surgical extraction be performed in young adults. PMID:24611086
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karim, Alamgir; Bucknall, David; Raghavan, Dharmaraj
2015-02-23
High efficiency solar energy devices can potentially meet all global energy requirements by efficiently harvesting energy from the solar spectrum. However, for solar technologies to be ubiquitous and meet the global power requirements, innovative and revolutionary approaches to trap solar energy are needed. In this regard, organic photovoltaics (OPVs) have drawn much attention, largely due to the ease with which OPVs can be manufactured at much lower costs compared to conventional inorganic PVs. Currently the most efficient OPV devices (at ~10%) are still below a technologically useful efficiency (~15%). It can be argued that to date most of the developmentmore » of the OPVs has been driven by their electronic properties, without much consideration or understanding of the structure and morphology of the organic components and in particular how these affect the performance of the solar cell devices. It is only in the last few years that the latter has begun to be addressed. Arguably, without a complete understanding of the effect of morphology and structure on device performance, the theoretical maximum efficiency of these devices is unlikely to ever be realized. A thorough understanding of the structure and morphology of the polymers and how this affects device efficiency is vital to achieve the full potential of OPVs. If OPV devices with 15% efficiency can be achieved, coupled with the predicted low cost of processing, such devices would create an enabling technology, making these types of solar cells significant power generators and thereby reduce the dependency on conventional energy sources. This would fulfill the economic solar energy challenge identified by the NAE in their Grand Challenges of the 21st Century. In this project, we conducted a directed series of experiments to determine morphology-property correlations in bulk heterojunction films by careful control of the OPV structure and morphology. Unlike most research undertaken in the PV arena, this is mostly a fundamental study that does not set out to evaluate new materials or produce devices, but rather we wish to understand from first principles how the molecular structure of polymer-fullerene mixtures determined using neutron scattering (small angle neutron scattering and neutron reflection) affects device characteristics and consequently performance. While this seems a very obvious question to ask, this critical understanding is far from being realized despite the wealth of studies into OPV’s and is severely limiting organic PV devices from achieving their theoretical potential. Despite the fundamental nature of proposed work, it is essential to remain technologically relevant and therefore to ensure we address these issues we have developed relationships on the fundamental nature of structure-processing-property paradigm as applied to future need for large area, flexible OPV devices. Nanoscale heterojunction systems consisting of fullerenes dispersed in conjugated polymers are promising materials candidates for achieving high performance organic photovoltaic (OPV) devices. In order to understand the phase behavior in these devices, neutron reflection is used to determine the behavior of model conjugated polymer-fullerene mixtures. Neutron reflection is particularly useful for these types of thin film studies since the fullerene generally have a high scattering contrast with respect to most polymers. We are studying model bulk heterojunction (BHJ) films based on mixtures of poly(3-hexyl thiophene)s (P3HT), a widely used photoconductive polymer, and different fullerenes (C60, PCBM and bis-PCBM). The characterization technique of neutron reflectivity measurements have been used to determine film morphology in a direction normal to the film surfaces. The novelty of the approach over previous studies is that the BHJ layer is sandwiched between a PEDOT/PSS and Al layers in real device configuration. Using this model system, the effect of typical thermal annealing processes on the film development as a function of the polythiophene-fullerene mixtures is measured.« less
NASA Astrophysics Data System (ADS)
Shi, Li-Bin; Li, Ming-Biao; Xiu, Xiao-Ming; Liu, Xu-Yang; Zhang, Kai-Cheng; Li, Chun-Ran; Dong, Hai-Kuan
2017-04-01
La2O3 is a potential dielectric material with high permittivity (high-κ) for metal-oxide-semiconductor (MOS) devices. However, band offsets and oxide defects should still be concerned. Smaller band offsets and carrier traps increase leakage current, and degenerate performance of the devices. In this paper, the interface behaviors of La2O3/GaAs under biaxial strain and hydrostatic pressure are investigated, which is performed by first principles calculations based on density functional theory (DFT). Strain engineering is attempted to improve performance of the metal/La2O3/GaAs devices. First of all, we creatively realize band alignment of La2O3/GaAs interface under biaxial strain and hydrostatic pressure. The proper biaxial tensile strain can effectively increase valence band offsets (VBO) and conduction band offsets (CBO), which can be used to suppress leakage current. However, the VBO will decrease with the increase of hydrostatic pressure, indicating that performance of the devices is degenerated. Then, a direct tunneling leakage current model is used to investigate current and voltage characteristics of the metal/La2O3/GaAs. The impact of biaxial strain and hydrostatic pressure on leakage current is discussed. At last, formation energies and transition levels of oxygen interstitial (Oi) and oxygen vacancy (VO) in La2O3 are assessed. We investigate how they will affect performance of the devices.
Nakashima, Ann; Farinaccio, Rocco
2015-04-01
Noise-induced hearing loss resulting from weapon noise exposure has been studied for decades. A summary of recent work in weapon noise signal analysis, current knowledge of hearing damage risk criteria, and auditory performance in impulse noise is presented. Most of the currently used damage risk criteria are based on data that cannot be replicated or verified. There is a need to address the effects of combined noise exposures, from similar or different weapons and continuous background noise, in future noise exposure regulations. Advancements in hearing protection technology have expanded the options available to soldiers. Individual selection of hearing protection devices that are best suited to the type of exposure, the auditory task requirements, and hearing status of the user could help to facilitate their use. However, hearing protection devices affect auditory performance, which in turn affects situational awareness in the field. This includes communication capability and the localization and identification of threats. Laboratory training using high-fidelity weapon noise recordings has the potential to improve the auditory performance of soldiers in the field, providing a low-cost tool to enhance readiness for combat. Reprint & Copyright © 2015 Association of Military Surgeons of the U.S.
[Performance dependence of organic light-emitting devices on the thickness of Alq3 emitting layer].
Lian, Jia-rong; Liao, Qiao-sheng; Yang, Rui-bo; Zheng, Wei; Zeng, Peng-ju
2010-10-01
The dependence of opto-electronical characteristics in organic light-emitting devices on the thickness of Alq3 emitter layer was studied, where MoO3, NPB, and Alq3 were used as hole injector, hole transporter, and emitter/electron transporter, respectively. By increasing the thickness of Alq3 layer from 20 to 100 nm, the device current decreased gradually, and the EL spectra of devices performed a little red shift with an obvious broadening in long wavelength range but a little decrease in intensity of short wavelength range. The authors simulated the EL spectra using the photoluminescence (PL) spectra of Alq3 as Alq3 intrinsic emission, which coincided with the experimental EL spectra well. The simulated results suggested that the effect of interference takes the major role in broadening the long wavelength range of EL spectra, and the distribution of emission zone largely affects the profile of EL spectra in short wavelength range.
Hand rehabilitation after stroke using a wearable, high DOF, spring powered exoskeleton.
Tianyao Chen; Lum, Peter S
2016-08-01
Stroke patients often have inappropriate finger flexor activation and finger extensor weakness, which makes it difficult to open their affected hand for functional grasp. The goal was to develop a passive, lightweight, wearable device to enable improved hand function during performance of activities of daily living. The device, HandSOME II, assists with opening the patient's hand using 11 elastic actuators that apply extension torques to finger and thumb joints. Device design and initial testing are described. A novel mechanical design applies forces orthogonal to the finger segments despite the fact that all of the device DOFs are not aligned with human joint DOF. In initial testing with seven stroke subjects with impaired hand function, use of HandSOME II significantly increased maximum extension angles and range of motion in all of the index finger joints (P<;0.05). HandSOME II allows performance of all the grip patterns used in daily activities and can be used as part of home-based therapy programs.
MEMS Actuators for Improved Performance and Durability
NASA Astrophysics Data System (ADS)
Yearsley, James M.
Micro-ElectroMechanical Systems (MEMS) devices take advantage of force-scaling at length scales smaller than a millimeter to sense and interact with directly with phenomena and targets at the microscale. MEMS sensors found in everyday devices like cell-phones and cars include accelerometers, gyros, pressure sensors, and magnetic sensors. MEMS actuators generally serve more application specific roles including micro- and nano-tweezers used for single cell manipulation, optical switching and alignment components, and micro combustion engines for high energy density power generation. MEMS rotary motors are actuators that translate an electric drive signal into rotational motion and can serve as rate calibration inputs for gyros, stages for optical components, mixing devices for micro-fluidics, etc. Existing rotary micromotors suffer from friction and wear issues that affect lifetime and performance. Attempts to alleviate friction effects include surface treatment, magnetic and electrostatic levitation, pressurized gas bearings, and micro-ball bearings. The present work demonstrates a droplet based liquid bearing supporting a rotary micromotor that improves the operating characteristics of MEMS rotary motors. The liquid bearing provides wear-free, low-friction, passive alignment between the rotor and stator. Droplets are positioned relative to the rotor and stator through patterned superhydrophobic and hydrophilic surface coatings. The liquid bearing consists of a central droplet that acts as the motor shaft, providing axial alignment between rotor and stator, and satellite droplets, analogous to ball-bearings, that provide tip and tilt stable operation. The liquid bearing friction performance is characterized through measurement of the rotational drag coefficient and minimum starting torque due to stiction and geometric effects. Bearing operational performance is further characterized by modeling and measuring stiffness, environmental survivability, and high-speed alignment capability. The superhydrophobic coatings developed for droplet containment are also discussed and measurements of contact angle are shown to affect device performance through correlation to models of bearing friction and stiffness.
NASA Astrophysics Data System (ADS)
Shekhar, Himanshu; Tzabari, Lior; Solomeshch, Olga; Tessler, Nir
2016-10-01
We have investigated the influence of the active layer thickness on the balance of the internal mechanisms affecting the efficiency of copper phthalocyanine - fullerene (C60) based vacuum deposited bulk heterojunction organic photocell. We fabricated a range of devices for which we varied the thickness of the active layer from 40 to 120 nm and assessed their performance using optical and electrical characterization techniques. As reported previously for phthalocyanine:C60, the performance of the device is highly dependent on the active layer thickness and of all the thicknesses we tried, the 40 nm thin active layer device showed the best solar cell characteristic parameters. Using the transfer matrix based optical model, which includes interference effects, we calculated the optical power absorbed in the active layers for the entire absorption band, and we found that this cannot explain the trend with thickness. Measurement of the cell quantum efficiency as a function of light intensity showed that the relative weight of the device internal processes changes when going from 40 nm to 120 nm thick active layer. Electrical modeling of the device, which takes different internal processes into account, allowed to quantify the changes in the processes affecting the generation - recombination balance. Sub gap external quantum efficiency and morphological analysis of the surface of the films agree with the model's result. We found that as the thickness grows the density of charge transfer states and of dark carriers goes up and the uniformity in the vertical direction is reduced.
Factors affecting the use and perceived benefit of ITE and BTE hearing aids.
Baumfield, A; Dillon, H
2001-08-01
The aim of the present study was to investigate factors that might affect hearing aid use, satisfaction and perceived benefit. A further aim was to look at which variables affect the choice of hearing aid, in particular, an in-the-ear (ITE) versus a behind-the-ear (BTE) device. Twenty-nine elderly hearing-impaired people with a mild-to-moderate hearing loss were fitted with both an ITE and a BTE hearing aid with similar electroacoustic performance. Both hearing aids were linear with output compression limiting and were fitted in a randomized order. After wearing each device for a six-week period, subj ets were asked to select the hearing aid they preferred. Variables significantly related to hearing aid choice, use and perceived benefit included ease of management, accuracy with which the NAL-R insertion gain target was achieved, earmould comfort and the type of hearing aid the client preferred initially.
Modelling of nanoscale multi-gate transistors affected by atomistic interface roughness
NASA Astrophysics Data System (ADS)
Nagy, Daniel; Aldegunde, Manuel; Elmessary, Muhammad A.; García-Loureiro, Antonio J.; Seoane, Natalia; Kalna, Karol
2018-04-01
Interface roughness scattering (IRS) is one of the major scattering mechanisms limiting the performance of non-planar multi-gate transistors, like Fin field-effect transistors (FETs). Here, two physical models (Ando’s and multi-sub-band) of electron scattering with the interface roughness induced potential are investigated using an in-house built 3D finite element ensemble Monte Carlo simulation toolbox including parameter-free 2D Schrödinger equation quantum correction that handles all relevant scattering mechanisms within highly non-equilibrium carrier transport. Moreover, we predict the effect of IRS on performance of FinFETs with realistic channel cross-section shapes with respect to the IRS correlation length (Λ) and RMS height (Δ_RMS ). The simulations of the n-type SOI FinFETs with the multi-sub-band IRS model shows its very strong effect on electron transport in the device channel compared to the Ando’s model. We have also found that the FinFETs are strongly affected by the IRS in the ON-region. The limiting effect of the IRS significantly increases as the Fin width is reduced. The FinFETs with <1 1 0> channel orientation are affected more by the IRS than those with the <1 0 0> crystal orientation. Finally, Λ and Δ_RMS are shown to affect the device performance similarly. A change in values by 30% (Λ) or 20% (Δ_RMS ) results in an increase (decrease) of up to 13% in the drive current.
Modelling of nanoscale multi-gate transistors affected by atomistic interface roughness.
Nagy, Daniel; Aldegunde, Manuel; Elmessary, Muhammad A; García-Loureiro, Antonio J; Seoane, Natalia; Kalna, Karol
2018-04-11
Interface roughness scattering (IRS) is one of the major scattering mechanisms limiting the performance of non-planar multi-gate transistors, like Fin field-effect transistors (FETs). Here, two physical models (Ando's and multi-sub-band) of electron scattering with the interface roughness induced potential are investigated using an in-house built 3D finite element ensemble Monte Carlo simulation toolbox including parameter-free 2D Schrödinger equation quantum correction that handles all relevant scattering mechanisms within highly non-equilibrium carrier transport. Moreover, we predict the effect of IRS on performance of FinFETs with realistic channel cross-section shapes with respect to the IRS correlation length (Λ) and RMS height ([Formula: see text]). The simulations of the n-type SOI FinFETs with the multi-sub-band IRS model shows its very strong effect on electron transport in the device channel compared to the Ando's model. We have also found that the FinFETs are strongly affected by the IRS in the ON-region. The limiting effect of the IRS significantly increases as the Fin width is reduced. The FinFETs with [Formula: see text] channel orientation are affected more by the IRS than those with the [Formula: see text] crystal orientation. Finally, Λ and [Formula: see text] are shown to affect the device performance similarly. A change in values by 30% (Λ) or [Formula: see text] ([Formula: see text]) results in an increase (decrease) of up to [Formula: see text] in the drive current.
Hydrophobic interaction and charge accumulation at the diamond-electrolyte interface.
Dankerl, M; Lippert, A; Birner, S; Stützel, E U; Stutzmann, M; Garrido, J A
2011-05-13
The hydrophobic interaction of surfaces with water is a well-known phenomenon, but experimental evidence of its influence on biosensor devices has been lacking. In this work we investigate diamond field-effect devices, reporting on Hall effect experiments and complementary simulations of the interfacial potential at the hydrogen-terminated diamond/aqueous electrolyte interface. The interfacial capacitance, derived from the gate-dependent Hall carrier concentration, can be modeled only when considering the hydrophobic nature of this surface and its influence on the structure of interfacial water. Our work demonstrates how profoundly the performance of potentiometric biosensor devices can be affected by their surfaces' hydrophobicity.
Property influence of polyanilines on photovoltaic behaviors of dye-sensitized solar cells.
Tan, Shuxin; Zhai, Jin; Xue, Bofei; Wan, Meixiang; Meng, Qingbo; Li, Yuliang; Jiang, Lei; Zhu, Daoben
2004-03-30
The influence of polyanilines (PANIs) as hole conductors on the photovoltaic behaviors of dye-sensitized solar cells is studied. The current-voltage (I-V) characteristics and the incident photon to current conversion efficiency (IPCE) curves of the devices are determined as the function of different conductivities and morphologies of PANIs. The results show that the conductivity of PANIs affects the performance of the devices greatly, and PANI with the intermediate conductivity value (3.5 S/cm) is optimum. In addition, the effects of both the film formation property and the cluster size of polyanilines on the photovoltaic behaviors of the devices are also discussed.
Effects of ethylene oxide sterilization on 82: 18 PLLA/PGA copolymer craniofacial fixation plates.
Pietrzak, William S
2010-01-01
Bioabsorbable devices are generally susceptible to some form of degradation or alteration of material properties in response to exposure to the terminal sterilization cycle. In addition to affecting the material strength, sterilization can also increase the rate of hydrolysis, both of which can impact clinical performance. The impact of sterilization on the material/device is unpredictable and must be empirically determined. This study examined the effects of ethylene oxide treatment on the material properties of LactoSorb 82:18 poly(L-lactic acid)-poly(glycolic acid) craniofacial plates. Compared with untreated control plates, there was no effect on the initial inherent viscosity (1.3 dL/g), the glass transition temperature (58 degrees C), or on the flexural mechanical properties. Furthermore, there was no effect on the in vitro rate of hydrolysis and mechanical strength loss profile. This provides evidence that the ethylene oxide sterilization cycle is compatible with these copolymer plates and that such treatment should not affect the clinical performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ok, Kyung-Chul; Park, Jin-Seong, E-mail: hkim-2@naver.com, E-mail: jsparklime@hanyang.ac.kr; Ko Park, Sang-Hee
We demonstrated the fabrication of flexible amorphous indium gallium zinc oxide thin-film transistors (TFTs) on high-temperature polyimide (PI) substrates, which were debonded from the carrier glass after TFT fabrication. The application of appropriate buffer layers on the PI substrates affected the TFT performance and stability. The adoption of the SiN{sub x}/AlO{sub x} buffer layers as water and hydrogen diffusion barriers significantly improved the device performance and stability against the thermal annealing and negative bias stress, compared to single SiN{sub x} or SiO{sub x} buffer layers. The substrates could be bent down to a radius of curvature of 15 mm and themore » devices remained normally functional.« less
Jensen, J L; Appel, L E; Clair, J H; Zentner, G M
1995-05-01
The feasibility of using modified Eudragit acrylic latexes as microporous coatings for osmotic devices was investigated. Potassium chloride tablets were coated with mixtures of Eudragit RS30D and RL30D acrylic latexes that also contained a plasticizer (triethyl citrate or acetyl tributyl citrate) and a pore-forming agent (urea). A 2(5-1) fractional factorial experimental design was employed to determine the effect of five formulation variables (RS30D:RL30D polymer ratio plasticizer type, plasticizer level, urea level, and cure) on the in vitro release rate of KCl in deionized water (di water), lag time, and coat burst strength. The RS30D:RL30D polymer ratio had the greatest effect on the release rate, and both lag time and burst strength were most affected by the urea level. Statistical optimization was performed, and a coat formulation with predicted desirable in vitro performance was prepared and tested. The in vitro release rate (di water), lag time, and coat burst strength agreed well with the prediction. Dissolutions were also performed in phosphate buffered saline (PBS; pH 7.4); several formulations released markedly slower in PBS than in di water. This discrepancy was dependent on the type of plasticizer and the amount of pore former. Only those coat formulations containing acetyl tributyl citrate as the plasticizer and a 100% urea [(g urea/g polymer solids) x 100] level exhibited similar release rates in di water and PBS. The mechanism of release from these devices was primarily osmotic, whereas the release from devices coated with a formulation containing triethyl citrate and 50% urea was not dependent on the osmotic pressure difference. Devices with an osmotic release mechanism behaved similarly in vivo and in vitro.(ABSTRACT TRUNCATED AT 250 WORDS)
Ejector Enhanced Pulsejet Based Pressure Gain Combustors: An Old Idea With a New Twist
NASA Technical Reports Server (NTRS)
Paxson, Daniel E.; Dougherty, Kevin T.
2005-01-01
An experimental investigation of pressure-gain combustion for gas turbine application is described. The test article consists of an off-the-shelf valved pulsejet, and an optimized ejector, both housed within a shroud. The combination forms an effective can combustor across which there is a modest total pressure rise rather than the usual loss found in conventional combustors. Although the concept of using a pulsejet to affect semi-constant volume (i.e., pressure-gain) combustion is not new, that of combining it with a well designed ejector to efficiently mix the bypass flow is. The result is a device which to date has demonstrated an overall pressure rise of approximately 3.5 percent at an overall temperature ratio commensurate with modern gas turbines. This pressure ratio is substantially higher than what has been previously reported in pulsejet-based combustion experiments. Flow non-uniformities in the downstream portion of the device are also shown to be substantially reduced compared to those within the pulsejet itself. The standard deviation of total pressure fluctuations, measured just downstream of the ejector was only 5.0 percent of the mean. This smoothing aspect of the device is critical to turbomachinery applications since turbine performance is, in general, negatively affected by flow non-uniformities and unsteadiness. The experimental rig will be described and details of the performance measurements will be presented. Analyses showing the thermodynamic benefits from this level of pressure-gain performance in a gas turbine will also be assessed for several engine types. Issues regarding practical development of such a device are discussed, as are potential emissions reductions resulting from the rich burning nature of the pulsejet and the rapid mixing (quenching) associated with unsteady ejectors.
NASA Astrophysics Data System (ADS)
Mei, Yang; Xu, Rong-Bin; Xu, Huan; Ying, Lei-Ying; Zheng, Zhi-Wei; Zhang, Bao-Ping; Li, Mo; Zhang, Jian
2018-01-01
Thermal characteristics of GaN-based vertical cavity surface emitting lasers (VCSELs) with three typical structures were investigated both theoretically and experimentally. The simulation results based on a steady state quasi three-dimensional cylindrical model show that the thermal resistance (R th) is affected by cavity length, mesa size, as well as the bottom distributed Bragg reflector (DBR) size, and the detail further depends on different structures. Among different devices, GaN VCSEL with a hybrid cavity formed by one nitride bottom DBR and another dielectric top DBR is featured with lower R th, which is meanwhile affected strongly by the materials of the epitaxial bottom DBR. The main issues affecting the thermal dissipation in VCSELs with double dielectric DBRs are the bottom dielectric DBR and the dielectric current-confinement layer. To validate the simulation results, GaN-based VCSEL bonded on a copper plate was fabricated. R th of this device was measured and the results agreed well with the simulation. This work provides a better understanding of the thermal characteristics of GaN-based VCSELs and is useful in optimizing the structure design and improving the device performance.
Tang, Tao; Tian, Jing; Zhong, Daijun; Fu, Chengyu
2016-06-25
A rate feed forward control-based sensor fusion is proposed to improve the closed-loop performance for a charge couple device (CCD) tracking loop. The target trajectory is recovered by combining line of sight (LOS) errors from the CCD and the angular rate from a fiber-optic gyroscope (FOG). A Kalman filter based on the Singer acceleration model utilizes the reconstructive target trajectory to estimate the target velocity. Different from classical feed forward control, additive feedback loops are inevitably added to the original control loops due to the fact some closed-loop information is used. The transfer function of the Kalman filter in the frequency domain is built for analyzing the closed loop stability. The bandwidth of the Kalman filter is the major factor affecting the control stability and close-loop performance. Both simulations and experiments are provided to demonstrate the benefits of the proposed algorithm.
Analysis of casing treatment’s impact on the axial compressor model stage characteristics
NASA Astrophysics Data System (ADS)
Tribunskaia, K.; Kozhukhov, Y. V.
2017-08-01
There are special requirements for the compressors of aircraft engines. They must ensure maximum efficiency in a maximally large stable work zone Due to a high pressure ratio these stages are more susceptible to the losses from radial clearance. One of the approaches to reduce such losses is the application of above-rotor devices. In the following study there is considered the impact of such treatments on the compressor stage performance. Despite the fact that there is a sufficient amount of research about this issue, their results are contradictory. The use of these devices can affect the characteristics of compressor stage performance both positively and negatively. This study was conducted using the methods of computational fluid dynamics and was based on the NASA Rotor-37 geometry model stage. Results were obtained through the comparison of the characteristics of stages with and without above-rotor devices.
Selective excitation of window and buffer layers in chalcopyrite devices and modules
Glynn, Stephen; Repins, Ingrid L.; Burst, James M.; ...
2018-02-02
Window and buffer layers in chalcopyrite devices are well known to affect junctions, conduction, and photo-absorption properties of the device. Some of these layers, particularly 'buffers,' which are deposited directly on top of the absorber, exhibit metastable effects upon exposure to light. Thus, to understand device performance and/or metastability, it is sometimes desirable to selectively excite different layers in the device stack. Absorption characteristics of various window and buffer layers used in chalcopyrite devices are measured. These characteristics are compared with emission spectra of common and available light sources that might be used to optically excite such layers. Effects ofmore » the window and buffer absorption on device quantum efficiency and metastability are discussed. For the case of bath-deposited Zn(O,S) buffers, we conclude that this layer is not optically excited in research devices or modules. Furthermore, this provides a complimentary mechanism to the chemical differences that may cause long time constants (compared to devices with CdS buffers) associated with reaching a stable 'light-soaked' state.« less
Selective excitation of window and buffer layers in chalcopyrite devices and modules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glynn, Stephen; Repins, Ingrid L.; Burst, James M.
Window and buffer layers in chalcopyrite devices are well known to affect junctions, conduction, and photo-absorption properties of the device. Some of these layers, particularly 'buffers,' which are deposited directly on top of the absorber, exhibit metastable effects upon exposure to light. Thus, to understand device performance and/or metastability, it is sometimes desirable to selectively excite different layers in the device stack. Absorption characteristics of various window and buffer layers used in chalcopyrite devices are measured. These characteristics are compared with emission spectra of common and available light sources that might be used to optically excite such layers. Effects ofmore » the window and buffer absorption on device quantum efficiency and metastability are discussed. For the case of bath-deposited Zn(O,S) buffers, we conclude that this layer is not optically excited in research devices or modules. Furthermore, this provides a complimentary mechanism to the chemical differences that may cause long time constants (compared to devices with CdS buffers) associated with reaching a stable 'light-soaked' state.« less
Jayaraman, C; Mummidisetty, C K; Jayaraman, A
2016-08-01
Accuracy of physical activity estimates predicted by activity monitoring technologies may be affected by device location, analysis algorithms, type of technology (i.e. wearable/stickable) and population demographics (disability) being studied. Consequently, the main purpose of this investigation was to study such sensor dynamics (i.e. effect of device location, type and population demographics on energy expenditure estimates) of two commercial activity monitors. It was hypothesized that device location, population studied (disability), choice of proprietary algorithm and type of technology used will significantly impact the accuracy of the predicted physical activity metrics. 10 healthy controls and eight individuals with spinal cord injury (SCI) performed structured activities in a laboratory environment. All participants wore, (i) three ActiGraph-G3TX's one each on their wrist, waist & ankle, (ii) a stickable activity monitor (Metria-IH1) on their upper-arm and (3) a Cosmed-K4B 2 metabolic unit, while performing sedentary (lying), low intensity (walk 50 steps at self-speed) and vigorous activity (a 6 minute walk test). To validate the hypothesis, the energy expenditures (EE) predicted by ActiGraph-GT3X and Metria-IH1 were benchmarked with estimated EE per Cosmed K4B 2 metabolic unit. To verify the step count accuracy predicted by ActiGraph-GT3X's and Metria-IH1, the manually calculated step count during the low intensity activity were compared to estimates from both devices. Results suggest that Metria-IH1 out-performed ActiGraph-GT3X in estimating EE during sedentary activity in both groups. The device location and population demographics, significantly affected the accuracy of predicted estimates. In conclusion, selecting activity monitor locations, analysis algorithm and choice of technology plays based on the movement threshold of population being studied can pave a better way for reliable healthcare decisions and data analytics in population with SCI.
Pestana Passos, S; Dias Vanderlei, A; Ozcan, M; Felipe Valandro, L F; Felipe Valandro, L
2011-03-01
This study evaluated, by scanning electron microscope (SEM) and EDS, the effect of different strategies for silica coating (sandblasters, time and distance) of a glass-infiltrated ceramic (In-Ceram Alumina). Forty-one ceramic blocks were produced. For comparison of the three air-abrasion devices, 15 ceramic samples were divided in three groups (N.=5): Bioart, Microetcher and Ronvig (air-abrasion parameters: 20 s at a distance of 10 mm). For evaluation of the time and distance factors, ceramic samples (N.=5) were allocated in groups considering three applied times (5 s, 13 s and 20 s) and two distances (10 mm and 20 mm), using the Ronvig device. In a control sample, no surface treatment was performed. After that, the micro-morphologic analyzes of the ceramic surfaces were made using SEM. EDS analyzes were carried out to detect the % of silica on representative ceramic surface. ANOVA and Tukey tests were used to analyze the results. One-way ANOVA showed the silica deposition was different for different devices (P=0.0054). The Ronvig device promoted the highest silica coating compared to the other devices (Tukey test). Two-way ANOVA showed the distance and time factors did not affect significantly the silica deposition (application time and distance showed no statistical difference). The Ronvig device provided the most effective silica deposition on glass-infiltrated alumina ceramic surface and the studied time and distance for air-abrasion did not affect the silica coating.
40 CFR 60.713 - Compliance provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... operator of the affected coating operation shall perform a liquid-liquid VOC material balance over each and... emission control device (other than a fixed-bed carbon adsorption system with individual exhaust stacks for...) when a fixed-bed carbon adsorption system with individual exhaust stacks for each adsorber vessel is...
40 CFR 60.713 - Compliance provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... operator of the affected coating operation shall perform a liquid-liquid VOC material balance over each and... emission control device (other than a fixed-bed carbon adsorption system with individual exhaust stacks for...) when a fixed-bed carbon adsorption system with individual exhaust stacks for each adsorber vessel is...
40 CFR 60.713 - Compliance provisions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... operator of the affected coating operation shall perform a liquid-liquid VOC material balance over each and... emission control device (other than a fixed-bed carbon adsorption system with individual exhaust stacks for...) when a fixed-bed carbon adsorption system with individual exhaust stacks for each adsorber vessel is...
Numerical and experimental investigations of micro air bearings for micro systems
NASA Astrophysics Data System (ADS)
Zhang, Qide; Shan, X. C.
2006-04-01
The paper investigated performance of air bearing system in a micro device. A parametric study is carried out. The dynamic performance of a very short journal bearing (L/D < 0.1) and thrust bearing is studied. The parameters that affect the performance of the air bearing are discussed. The optimum values of the important parameters are explored, and the stability of the thrust bearing is discussed. The prototype and test result are presented.
On the Properties and Design of Organic Light-Emitting Devices
NASA Astrophysics Data System (ADS)
Erickson, Nicholas C.
Organic light-emitting devices (OLEDs) are attractive for use in next-generation display and lighting technologies. In display applications, OLEDs offer a wide emission color gamut, compatibility with flexible substrates, and high power efficiencies. In lighting applications, OLEDs offer attractive features such as broadband emission, high-performance, and potential compatibility with low-cost manufacturing methods. Despite recent demonstrations of near unity internal quantum efficiencies (photons out per electron in), OLED adoption lags conventional technologies, particularly in large-area displays and general lighting applications. This thesis seeks to understand the optical and electronic properties of OLED materials and device architectures which lead to not only high peak efficiency, but also reduced device complexity, high efficiency under high excitation, and optimal white-light emission. This is accomplished through the careful manipulation of organic thin film compositions fabricated via vacuum thermal evaporation, and the introduction of a novel device architecture, the graded-emissive layer (G-EML). This device architecture offers a unique platform to study the electronic properties of varying compositions of organic semiconductors and the resulting device performance. This thesis also introduces an experimental technique to measure the spatial overlap of electrons and holes within an OLED's emissive layer. This overlap is an important parameter which is affected by the choice of materials and device design, and greatly impacts the operation of the OLED at high excitation densities. Using the G-EML device architecture, OLEDs with improved efficiency characteristics are demonstrated, achieving simultaneously high brightness and high efficiency.
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, E. R., E-mail: ewhite@physics.ucla.edu; Kerelsky, Alexander; Hubbard, William A.
2015-11-30
Heterostructure devices with specific and extraordinary properties can be fabricated by stacking two-dimensional crystals. Cleanliness at the inter-crystal interfaces within a heterostructure is crucial for maximizing device performance. However, because these interfaces are buried, characterizing their impact on device function is challenging. Here, we show that electron-beam induced current (EBIC) mapping can be used to image interfacial contamination and to characterize the quality of buried heterostructure interfaces with nanometer-scale spatial resolution. We applied EBIC and photocurrent imaging to map photo-sensitive graphene-MoS{sub 2} heterostructures. The EBIC maps, together with concurrently acquired scanning transmission electron microscopy images, reveal how a device's photocurrentmore » collection efficiency is adversely affected by nanoscale debris invisible to optical-resolution photocurrent mapping.« less
Tippey, Kathryn G; Sivaraj, Elayaraj; Ferris, Thomas K
2017-06-01
This study evaluated the individual and combined effects of voice (vs. manual) input and head-up (vs. head-down) display in a driving and device interaction task. Advances in wearable technology offer new possibilities for in-vehicle interaction but also present new challenges for managing driver attention and regulating device usage in vehicles. This research investigated how driving performance is affected by interface characteristics of devices used for concurrent secondary tasks. A positive impact on driving performance was expected when devices included voice-to-text functionality (reducing demand for visual and manual resources) and a head-up display (HUD) (supporting greater visibility of the driving environment). Driver behavior and performance was compared in a texting-while-driving task set during a driving simulation. The texting task was completed with and without voice-to-text using a smartphone and with voice-to-text using Google Glass's HUD. Driving task performance degraded with the addition of the secondary texting task. However, voice-to-text input supported relatively better performance in both driving and texting tasks compared to using manual entry. HUD functionality further improved driving performance compared to conditions using a smartphone and often was not significantly worse than performance without the texting task. This study suggests that despite the performance costs of texting-while-driving, voice input methods improve performance over manual entry, and head-up displays may further extend those performance benefits. This study can inform designers and potential users of wearable technologies as well as policymakers tasked with regulating the use of these technologies while driving.
High performance quantum cascade lasers: Loss, beam stability, and gain engineering
NASA Astrophysics Data System (ADS)
Bouzi, Pierre Michel
Quantum Cascade (QC) lasers are semiconductor devices emitting in the mid-infrared (3-30 micron) and terahertz (30-300 micron) regions of the electromagnetic spectrum. Since their first demonstration by Jerome Faist et. al. in 1994, they have evolved very quickly into high performance devices and given rise to many applications such as trace-gas sensing, medical diagnosis, free-space communication, and light detection and ranging (LIDAR). In this thesis, we investigate a further increase of the performance of QC devices and, through meticulous device modeling and characterizations, gain a deeper understanding of several of their unique characteristics, especially their carrier transport and lifetime, their characteristic temperature, their waveguide loss and modal gain, their leakage current, and their transverse mode profile. First, in our quest to achieve higher performance, we investigate the effect of growth asymmetries on device transport characteristics. This investigation stems from recent studies on the role of interface roughness on intersubband scattering and device performance. Through a symmetric active core design, we find that interface roughness and ionized impurity scattering induced by dopant migration play a significant role in carrier transport through the device. Understanding how interface roughness affects intersubband scattering, in turn, we engineer the gain in QC devices by placing monolayer barriers at specific locations within the device band structure. These strategically placed additional thin barrier layers introduce roughness scattering into the device active region, thereby selectively decreasing the lower laser state lifetime and increasing population inversion necessary for laser action. Preliminary measurement results from modified devices reveal a 50% decrease in the emission broadening compared to the control structures, which should lead to a two-fold increase in gain. A special class of so-called "strong coupling" QC lasers recently emerged with high optical power and high efficiency at cryogenic temperatures. However their performances decay rather rapidly with temperature in both pulsed and continuous wave modes. Through detailed measurements and analysis, we investigate several possible causes of this shortcoming and propose design modifications for temperature performance improvement. While the strong coupling devices are efficient and powerful, their performance often suffers from unintentional and potentially harmful beam steering at high power. Here, we identify the root of this pointing instability to be from non-linear interactions between multiple transverse modes. And, to resolve this issue, we employ focused ion beam (FIB) milling to etch small lateral constrictions on top of the devices and fill them with metal. This has the effect of greatly reducing the intensity of higher order transverse modes as they propagate through the cavity. A good grasp of the microscopic details involved in QC device operations will result in better lasers, with high beam quality. This, in turn, will enable new applications, such as the detection of SO2 isotopologues near 7.4 micron, which is of particular importance for the study of ultraviolet photolysis and the sulfur cycle on Venus.
Yang, Qing; Wu, Yuanpeng; Liu, Ying; Pan, Caofeng; Wang, Zhong Lin
2014-02-21
The piezo-phototronic effect, a three way coupling effect of piezoelectric, semiconductor and photonic properties in non-central symmetric semiconductor materials, utilizing the piezo-potential as a "gate" voltage to tune the charge transport/generation/recombination and modulate the performance of optoelectronic devices, has formed a new field and attracted lots of interest recently. The mechanism was verified in various optoelectronic devices such as light emitting diodes (LEDs), photodetectors and solar cells etc. The fast development and dramatic increasing interest in the piezo-phototronic field not only demonstrate the way the piezo-phototronic effects work, but also indicate the strong need for further research in the physical mechanism and potential applications. Furthermore, it is important to distinguish the contribution of the piezo-phototronic effect from other factors induced by external strain such as piezoresistance, band shifting or contact area change, which also affect the carrier behaviour and device performance. In this perspective, we review our recent progress on piezo-phototronics and especially focus on pointing out the features of piezo-phototronic effect in four aspects: I-V characteristics; c-axis orientation; influence of illumination; and modulation of carrier behaviour. Finally we proposed several criteria for describing the contribution made by the piezo-phototronic effect to the performance of optoelectronic devices. This systematic analysis and comparison will not only help give an in-depth understanding of the piezo-phototronic effect, but also work as guide for the design of devices in related areas.
Superconducting hot electron bolometers for terahertz sensing
NASA Astrophysics Data System (ADS)
Reese, Matthew Owen
Superconducting Hot Electron Bolometers (HEBs) are good candidates for detecting weak signals in the submillimeter or terahertz range. In this thesis work, a novel fabrication method was developed to make two types of niobium HEBs for different applications. HEBs were designed, fabricated, and then characterized at dc, microwave, and THz frequencies. The first type is a diffusion-cooled HEB, made with a short bridge that determines its cooling time. In this thesis, bridges were typically 400 nm long with bandwidths of about 1 GHz. These diffusion-cooled HEBs were developed as part of a collaboration with the University of Arizona (UA), to develop a proof-of-concept heterodyne array submillimeter camera. Devices were fabricated on thin fused quartz and silica substrates for waveguide coupling in the UA system for the astrophysically interesting 345 and 810 GHz atmospheric windows. The goal of this collaboration is to provide a basis of comparison between Nb diffusion-cooled HEB mixers and superconductorinsulator-superconductor mixers at these frequencies. The second type is a phonon-cooled HEB, made with a ˜3 mum long bridge. Its thermal response is dictated by the electron-phonon relaxation time. These devices were developed in collaboration with Prof. C. Schmuttenmaer's lab in the Yale Chemistry department, Prof. G. Blake at Caltech, and Dr. J. Pearson at the Jet Propulsion Laboratory. These devices were developed for use in quasi-optic systems to be used as fast (>100 MHz) direct detectors that can view room temperature sources without saturating. A variety of experimental applications are envisioned for these detectors including charge transport measurements of novel materials. A series of dc and microwave measurements were performed on the diffusion-cooled devices. A better understanding of the resistance vs. temperature profile was realized, including what design/fabrication parameters affect it and insight into how it affects device performance. This led to a do screening process that can identify good quality devices. The Nb phonon-cooled HEBs studied in this thesis were fully carried through the design, fabrication, and characterization process at dc, microwave and THz frequencies. The saturation power, responsivity, thermal response time, and noise performance were all measured to be within the expected range predicted by the initial design parameters.
Development of Magnetorheological Resistive Exercise Device for Rowing Machine
Žiliukas, Pranas
2016-01-01
Training equipment used by professional sportsmen has a great impact on their sport performance. Most universal exercisers may help only to improve the general physical condition due to the specific kinematics and peculiar resistance generated by their loading units. Training of effective techniques and learning of psychomotor skills are possible only when exercisers conform to the movements and resistance typical for particular sports kinematically and dynamically. Methodology of developing a magnetorheological resistive exercise device for generating the desired law of passive resistance force and its application in a lever-type rowing machine are described in the paper. The structural parameters of a controllable hydraulic cylinder type device were found by means of the computational fluid dynamics simulation performed by ANSYS CFX software. Parameters describing the magnetorheological fluid as non-Newtonian were determined by combining numerical and experimental research of the resistance force generated by the original magnetorheological damper. A structural scheme of the device control system was developed and the variation of the strength of magnetic field that affects the magnetorheological fluid circulating in the device was determined, ensuring a variation of the resistance force on the oar handle adequate for the resistance that occurs during a real boat rowing stroke. PMID:27293479
Development of Magnetorheological Resistive Exercise Device for Rowing Machine.
Grigas, Vytautas; Šulginas, Anatolijus; Žiliukas, Pranas
2015-01-01
Training equipment used by professional sportsmen has a great impact on their sport performance. Most universal exercisers may help only to improve the general physical condition due to the specific kinematics and peculiar resistance generated by their loading units. Training of effective techniques and learning of psychomotor skills are possible only when exercisers conform to the movements and resistance typical for particular sports kinematically and dynamically. Methodology of developing a magnetorheological resistive exercise device for generating the desired law of passive resistance force and its application in a lever-type rowing machine are described in the paper. The structural parameters of a controllable hydraulic cylinder type device were found by means of the computational fluid dynamics simulation performed by ANSYS CFX software. Parameters describing the magnetorheological fluid as non-Newtonian were determined by combining numerical and experimental research of the resistance force generated by the original magnetorheological damper. A structural scheme of the device control system was developed and the variation of the strength of magnetic field that affects the magnetorheological fluid circulating in the device was determined, ensuring a variation of the resistance force on the oar handle adequate for the resistance that occurs during a real boat rowing stroke.
NASA Astrophysics Data System (ADS)
Kashiwagi, Takanari; Tanaka, Taiga; Watanabe, Chiharu; Kubo, Hiroyuki; Komori, Yuki; Yuasa, Takumi; Tanabe, Yuki; Ota, Ryusei; Kuwano, Genki; Nakamura, Kento; Tsujimoto, Manabu; Minami, Hidetoshi; Yamamoto, Takashi; Klemm, Richard A.; Kadowaki, Kazuo
2017-12-01
Joule heating is the central issue in order to develop high-power and high-performance terahertz (THz) emission from mesa devices employing the intrinsic Josephson junctions in a layered high transition-temperature Tc superconductor. Here, we describe a convenient local thermal measurement technique using charge-coupled-device-based thermoreflectance microscopy, with the highest spatial resolution to date. This technique clearly proves that the relative temperature changes of the mesa devices between different bias points on the current-voltage characteristics can be measured very sensitively. In addition, the heating characteristics on the surface of the mesa devices can be detected more directly without any special treatment of the mesa surface such as previous coatings with SiC micro-powders. The results shown here clearly indicate that the contact resistance strongly affects the formation of an inhomogeneous temperature distribution on the mesa structures. Since the temperature and sample dependencies of the Joule heating characteristics can be measured quickly, this simple thermal evaluation technique is a useful tool to check the quality of the electrical contacts, electrical wiring, and sample defects. Thus, this technique could help to reduce the heating problems and to improve the performance of superconducting THz emitter devices.
Engineering of superconductors and superconducting devices using artificial pinning sites
NASA Astrophysics Data System (ADS)
Wördenweber, Roger
2017-08-01
Vortex matter in superconducting films and devices is not only an interesting topic for basic research but plays a substantial role in the applications of superconductivity in general. We demonstrate, that in most electronic applications, magnetic flux penetrates the superconductor and affects the performance of superconducting devices. Therefore, vortex manipulation turns out to be a useful tool to avoid degradation of superconducting device properties. Moreover, it can also be used to analyze and understand novel and interesting physical properties and develop new concepts for superconductor applications. In this review, various concepts for vortex manipulation are sketched. For example, the use of micro- and nanopatterns (especially, antidots) for guiding and trapping of vortices in superconducting films and thin film devices is discussed and experimental evidence of their vortex guidance and vortex trapping by various arrangements of antidots is given. We demonstrate, that the vortex state of matter is very important in applications of superconductivity. A better understanding does not only lead to an improvement of the performance of superconductor components, such as reduced noise, better power handling capability, or improved reliability, it also promises deeper insight into the basic physics of vortices and vortex matter.
Broadband temperature-insensitivity of dispersion-engineered waveguides and resonators
NASA Astrophysics Data System (ADS)
Xu, Lijuan; He, Liuqing; Guo, Yuhao; Li, Guifang; Zhang, Lin
2018-02-01
Photonic circuits suffer from thermal drift of device performance, which is a key obstacle to the development of commercial optoelectronic products. Temperature-insensitive integrated waveguides and resonators have been demonstrated by using materials with a negative TOC at a single wavelength, which are not suitable for WDM devices and wideband nonlinear devices. Here, we propose a waveguide structure with temperature-insensitivity over a bandwidth of 780 nm (1280 to 2060 nm) with an ultra-small effective TOC within +/-1×10-6/K. Uniquely, the waveguide has small anomalous dispersion (from 66 to 329 ps/nm/km) over the same band and is suitable for frequency comb generation without being affected by intra-cavity thermal dynamics.
Reformulation as a Measure of Student Expression in Classroom Interaction.
ERIC Educational Resources Information Center
Dobson, James J.
1995-01-01
Investigates teacher reformulation of student talk in order to determine the manner in which teachers affect student meaning and expression. Findings indicate that reformulation is a device used by teachers to control classroom dialog and that teachers disproportionately perform the language functions most commonly associated with higher-order…
Layout-aware simulation of soft errors in sub-100 nm integrated circuits
NASA Astrophysics Data System (ADS)
Balbekov, A.; Gorbunov, M.; Bobkov, S.
2016-12-01
Single Event Transient (SET) caused by charged particle traveling through the sensitive volume of integral circuit (IC) may lead to different errors in digital circuits in some cases. In technologies below 180 nm, a single particle can affect multiple devices causing multiple SET. This fact adds the complexity to fault tolerant devices design, because the schematic design techniques become useless without their layout consideration. The most common layout mitigation technique is a spatial separation of sensitive nodes of hardened circuits. Spatial separation decreases the circuit performance and increases power consumption. Spacing should thus be reasonable and its scaling follows the device dimensions' scaling trend. This paper presents the development of the SET simulation approach comprised of SPICE simulation with "double exponent" current source as SET model. The technique uses layout in GDSII format to locate nearby devices that can be affected by a single particle and that can share the generated charge. The developed software tool automatizes multiple simulations and gathers the produced data to present it as the sensitivity map. The examples of conducted simulations of fault tolerant cells and their sensitivity maps are presented in this paper.
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, Santhisagar; Burgess, Diane J; Tomazos, Ioannis; Jain, Faquir C; Papadimitrakopoulos, Fotios
2010-01-01
Devices for continuous glucose monitoring (CGM) are currently a major focus of research in the area of diabetes management. It is envisioned that such devices will have the ability to alert a diabetes patient (or the parent or medical care giver of a diabetes patient) of impending hypoglycemic/hyperglycemic events and thereby enable the patient to avoid extreme hypoglycemic/hyperglycemic excursions as well as minimize deviations outside the normal glucose range, thus preventing both life-threatening events and the debilitating complications associated with diabetes. It is anticipated that CGM devices will utilize constant feedback of analytical information from a glucose sensor to activate an insulin delivery pump, thereby ultimately realizing the concept of an artificial pancreas. Depending on whether the CGM device penetrates/breaks the skin and/or the sample is measured extracorporeally, these devices can be categorized as totally invasive, minimally invasive, and noninvasive. In addition, CGM devices are further classified according to the transduction mechanisms used for glucose sensing (i.e., electrochemical, optical, and piezoelectric). However, at present, most of these technologies are plagued by a variety of issues that affect their accuracy and long-term performance. This article presents a critical comparison of existing CGM technologies, highlighting critical issues of device accuracy, foreign body response, calibration, and miniaturization. An outlook on future developments with an emphasis on long-term reliability and performance is also presented. PMID:21129353
Performance of GPS-devices for environmental exposure assessment.
Beekhuizen, Johan; Kromhout, Hans; Huss, Anke; Vermeulen, Roel
2013-01-01
Integration of individual time-location patterns with spatially resolved exposure maps enables a more accurate estimation of personal exposures to environmental pollutants than using estimates at fixed locations. Current global positioning system (GPS) devices can be used to track an individual's location. However, information on GPS-performance in environmental exposure assessment is largely missing. We therefore performed two studies. First, a commute-study, where the commute of 12 individuals was tracked twice, testing GPS-performance for five transport modes and two wearing modes. Second, an urban-tracking study, where one individual was tracked repeatedly through different areas, focused on the effect of building obstruction on GPS-performance. The median error from the true path for walking was 3.7 m, biking 2.9 m, train 4.8 m, bus 4.9 m, and car 3.3 m. Errors were larger in a high-rise commercial area (median error=7.1 m) compared with a low-rise residential area (median error=2.2 m). Thus, GPS-performance largely depends on the transport mode and urban built-up. Although ~85% of all errors were <10 m, almost 1% of the errors were >50 m. Modern GPS-devices are useful tools for environmental exposure assessment, but large GPS-errors might affect estimates of exposures with high spatial variability.
Traveling-wave tube reliability estimates, life tests, and space flight experience
NASA Technical Reports Server (NTRS)
Lalli, V. R.; Speck, C. E.
1977-01-01
Infant mortality, useful life, and wearout phase of twt life are considered. The performance of existing developmental tubes, flight experience, and sequential hardware testing are evaluated. The reliability history of twt's in space applications is documented by considering: (1) the generic parts of the tube in light of the manner in which their design and operation affect the ultimate reliability of the device, (2) the flight experience of medium power tubes, and (3) the available life test data for existing space-qualified twt's in addition to those of high power devices.
Simulation of thermal management in AlGaN/GaN HEMTs with integrated diamond heat spreaders
NASA Astrophysics Data System (ADS)
Wang, A.; Tadjer, M. J.; Calle, F.
2013-05-01
We investigated the impact of diamond heat spreading layers on the performance of AlGaN/GaN high-electron-mobility-transistors (HEMTs). A finite element method was used to simulate the thermal and electrical characteristics of the devices under dc and pulsed operation conditions. The results show that the device performance can be improved significantly by optimized heat spreading, an effect strongly dependent on the lateral thermal conductivity of the initial several micrometers of diamond deposition. Of crucial importance is the proximity of the diamond layer to the heat source, which makes this method advantageous over other thermal management procedures, especially for the device in pulsed operation. In this case, the self-heating effect can be suppressed, and it is not affected by either the substrate or its thermal boundary resistance at the GaN/substrate at wider pulses. The device with a 5 µm diamond layer can present 10.5% improvement of drain current, and the self-heating effect can be neglected for a 100 ns pulse width at 1 V gate and 20 V drain voltage.
Lee, Woongki; Song, Myeonghun; Park, Soohyung; Nam, Sungho; Seo, Jooyeok; Kim, Hwajeong; Kim, Youngkyoo
2016-01-01
Organic thermoelectric devices (OTEDs) are recognized one of the next generation energy conversion platforms because of their huge potentials for securing electricity continuously from even tiny heat sources in our daily life. The advantage of OTEDs can be attributable to the design freedom in device shapes and the low-cost fabrication by employing solution coating processes at low temperatures. As one of the major OTE materials to date, poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) has been used, but no study has been yet carried out on its acidity control even though the acidic components in OTEDs can seriously affect the device performance upon operation. Here we demonstrate that the addition of aniline (a weak base) can control the acidity of PEDOT:PSS and enhance the performance of OTEDs. In particular, the vertical OTEDs with aniline-doped PEDOT:PSS films (active area = 1.0 cm2) could continuously generate electricity (0.06 nW) even at low temperatures (<38 °C) when they were mounted on a desk lamp (power = 24 W). PMID:27667013
NASA Astrophysics Data System (ADS)
Lee, Woongki; Song, Myeonghun; Park, Soohyung; Nam, Sungho; Seo, Jooyeok; Kim, Hwajeong; Kim, Youngkyoo
2016-09-01
Organic thermoelectric devices (OTEDs) are recognized one of the next generation energy conversion platforms because of their huge potentials for securing electricity continuously from even tiny heat sources in our daily life. The advantage of OTEDs can be attributable to the design freedom in device shapes and the low-cost fabrication by employing solution coating processes at low temperatures. As one of the major OTE materials to date, poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) has been used, but no study has been yet carried out on its acidity control even though the acidic components in OTEDs can seriously affect the device performance upon operation. Here we demonstrate that the addition of aniline (a weak base) can control the acidity of PEDOT:PSS and enhance the performance of OTEDs. In particular, the vertical OTEDs with aniline-doped PEDOT:PSS films (active area = 1.0 cm2) could continuously generate electricity (0.06 nW) even at low temperatures (<38 °C) when they were mounted on a desk lamp (power = 24 W).
NASA Technical Reports Server (NTRS)
Schwartz, Robert W.; Ballato, J.; Northwang, W. D.; Laoratanakul, P.
2000-01-01
Dome formation in Rainbow and Thunder actuators occurs to relieve thermal expansion mismatch stress between the metallic and piezoelectric layers during cooling from device fabrication temperatures. Accompanying this process is the generation of an internal stress profile within the devices and the development of significant tensile stresses within the surface region of the piezoelectric. These tensile stresses affect the domain configuration (ratio of c-to-a domains), and improve the 90 deg. domain wall movement response of the device in this region of the piezoelectric. This results in improved electromechanical performance compared to standard direct extensional and flextensional devices, presumably because of the contributions of stress to the non-linearity of the piezoelectric d-coefficients. 1 Interestingly, this improvement in response seems counterintuitive; a stress perpendicular to the direction of the applied electric field should impede, not contribute to 90' domain switching. Further consideration of the lower region of the piezoelectric that is under compressive stress thus appears warranted. The specified objectives of the research were to: 1. Conduct finite element and equivalent circuit simulation-based investigations to understand the effects of actuator geometry on internal stress distribution and actuator performance (displacement and load-bearing capabilities). 2. Use the results of the modeling studies to predict the processing conditions (geometry and thickness ratio) required for the fabrication of Rainbow ceramics with optimized performance.
Thermal engineering of FAPbI3 perovskite material via radiative thermal annealing and in situ XRD
Pool, Vanessa L.; Dou, Benjia; Van Campen, Douglas G.; Klein-Stockert, Talysa R.; Barnes, Frank S.; Shaheen, Sean E.; Ahmad, Md I.; van Hest, Maikel F. A. M.; Toney, Michael F.
2017-01-01
Lead halide perovskites have emerged as successful optoelectronic materials with high photovoltaic power conversion efficiencies and low material cost. However, substantial challenges remain in the scalability, stability and fundamental understanding of the materials. Here we present the application of radiative thermal annealing, an easily scalable processing method for synthesizing formamidinium lead iodide (FAPbI3) perovskite solar absorbers. Devices fabricated from films formed via radiative thermal annealing have equivalent efficiencies to those annealed using a conventional hotplate. By coupling results from in situ X-ray diffraction using a radiative thermal annealing system with device performances, we mapped the processing phase space of FAPbI3 and corresponding device efficiencies. Our map of processing-structure-performance space suggests the commonly used FAPbI3 annealing time, 10 min at 170 °C, can be significantly reduced to 40 s at 170 °C without affecting the photovoltaic performance. The Johnson-Mehl-Avrami model was used to determine the activation energy for decomposition of FAPbI3 into PbI2. PMID:28094249
Thermal engineering of FAPbI 3 perovskite material via radiative thermal annealing and in situ XRD
Pool, Vanessa L.; Dou, Benjia; Van Campen, Douglas G.; ...
2017-01-17
Lead halide perovskites have emerged as successful optoelectronic materials with high photovoltaic power conversion efficiencies and low material cost. However, substantial challenges remain in the scalability, stability and fundamental understanding of the materials. Here we present the application of radiative thermal annealing, an easily scalable processing method for synthesizing formamidinium lead iodide (FAPbI 3) perovskite solar absorbers. Devices fabricated from films formed via radiative thermal annealing have equivalent efficiencies to those annealed using a conventional hotplate. By coupling results from in situ X-ray diffraction using a radiative thermal annealing system with device performances, we mapped the processing phase space ofmore » FAPbI 3 and corresponding device efficiencies. Our map of processing-structure-performance space suggests the commonly used FAPbI 3 annealing time, 10 min at 170 degrees C, can be significantly reduced to 40 s at 170 degrees C without affecting the photovoltaic performance. Lastly, the Johnson-Mehl-Avrami model was used to determine the activation energy for decomposition of FAPbI 3 into PbI 2.« less
Investigation of low glass transition temperature on COTS PEMs reliability
NASA Technical Reports Server (NTRS)
Sandor, M.; Agarwal, S.
2002-01-01
Many factors influence PEM component reliability.One of the factors that can affect PEM performance and reliability is the glass transition temperature (Tg) and the coefficient of thermal expansion (CTE) of the encapsulant or underfill. JPL/NASA is investigating how the Tg and CTE for PEMs affect device reliability under different temperature and aging conditions. Other issues with Tg are also being investigated. Some preliminary data will be presented on glass transition temperature test results conducted at JPL.
NASA Astrophysics Data System (ADS)
Lu, Zhengda; Erickson, David
2017-03-01
Vitamin A and iron deficiency are common malnutrition affecting billions of people worldwide. However, in infrastructure limited settings, access to blood vitamin A and iron status test is limited because of the complexity and cost of traditional diagnostic methods. Direct measurements of vitamin A and iron level is not easy to perform, and it is necessary to measure approximate marker for obtaining vitamin A and iron deficiency status. Measurement of inflammatory marker is also necessary because the vitamin A and iron level are altered by inflammation status. Here we introduced a multiplex rapid point-of-care (POC) diagnostic devices that simultaneously characterize three markers relevant to vitamin A, iron and inflammation status: retinol binding protein 4, ferritin and C-reactive protein with lateral flow immunoassay test strips. Level of retinol binding protein 4, ferritin and C-reactive protein are indicated by excitation intensity of fluorescence tags with three different colors. The test can be done within 15 minutes and a complete sample-answer quantitative results of vitamin A, iron and inflammation status level can be obtained with assists of a smartphone and an external device. We also demonstrated the device is able to perform colorimetric analysis on single test area. which gives the device potential to perform more tests simultaneously at the same time.
Current-induced changes of migration energy barriers in graphene and carbon nanotubes
NASA Astrophysics Data System (ADS)
Obodo, J. T.; Rungger, I.; Sanvito, S.; Schwingenschlögl, U.
2016-05-01
An electron current can move atoms in a nanoscale device with important consequences for the device operation and breakdown. We perform first principles calculations aimed at evaluating the possibility of changing the energy barriers for atom migration in carbon-based systems. In particular, we consider the migration of adatoms and defects in graphene and carbon nanotubes. Although the current-induced forces are large for both the systems, in graphene the force component along the migration path is small and therefore the barrier height is little affected by the current flow. In contrast, the same barrier is significantly reduced in carbon nanotubes as the current increases. Our work also provides a real-system numerical demonstration that current-induced forces within density functional theory are non-conservative.An electron current can move atoms in a nanoscale device with important consequences for the device operation and breakdown. We perform first principles calculations aimed at evaluating the possibility of changing the energy barriers for atom migration in carbon-based systems. In particular, we consider the migration of adatoms and defects in graphene and carbon nanotubes. Although the current-induced forces are large for both the systems, in graphene the force component along the migration path is small and therefore the barrier height is little affected by the current flow. In contrast, the same barrier is significantly reduced in carbon nanotubes as the current increases. Our work also provides a real-system numerical demonstration that current-induced forces within density functional theory are non-conservative. Electronic supplementary information (ESI) available. See DOI: 10.1039/C6NR00534A
Lim, Tae Ho; Oh, Jaehoon; Lee, Juncheol; Shin, Hyungoo
2018-01-01
Emergency physicians are at risk of infection during invasive procedures, and wearing a respirator can reduce this risk. The aim of this study was to determine whether the protection afforded by a respirator during intubation is affected by the type of airway device used. In this randomized crossover study, 26 emergency physicians underwent quantitative fit tests for a N95 respirator (cup-type or fold-type) before and during intubation with a direct laryngoscope, GlideScope®, or i-gel® airway device. The primary outcome was the fit factor value of the respirator and the secondary outcome was the level of acceptable protection provided (percentage of fit factor scores above 100). Compared with the GlideScope and i-gel device, the fit factor values and level of acceptable protection provided were lower when physicians wore the cup-type respirator while intubating using the direct laryngoscope (200 fit factor [152–200] and 200 fit factor [121.25–200] versus 166 fit factor [70–200], 100% and 100% versus 75%, respectively; all P < 0.001). There were no significant differences in the fit factor value or level of acceptable protection provided when the physicians wore the fold-type respirator while intubating using any of the three airway devices (all P > 0.05). The type of airway device used for endotracheal intubation may influence the protective performance of some types of respirators. Emergency physicians should consider the effects of airway device types on fit factor of N95 respirators, when they perform intubation at risk of infection. PMID:29672533
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tittmann-Otto, J., E-mail: jana.tittmann-otto@zfm.tu-chemnitz.de; Hermann, S.; Hartmann, M.
The interface between a carbon nanotube (CNT) and its environment can dramatically affect the electrical properties of CNT-based field-effect transistors (FETs). For such devices, the channel environment plays a significant role inducing doping or charge traps giving rise to hysteresis in the transistor characteristics. Thereby the fabrication process strongly determines the extent of those effects and the final device performance. In CNT-based devices obtained from dispersions, a proper individualization of the nanotubes is mandatory. This is generally realized by an ultrasonic treatment combined with surfactant molecules, which enwrap nanotubes forming micelle aggregates. To minimize impact on device performance, it ismore » of vital importance to consider post-deposition treatments for removal of surfactant molecules and other impurities. In this context, we investigated the effect of several wet chemical cleaning and thermal post treatments on the electrical characteristics as well as physical properties of more than 600 devices fabricated only by wafer-level compatible technologies. We observed that nitric acid and water treatments improved the maximum-current of devices. Additionally, we found that the ethanol treatment successfully lowered hysteresis in the transfer characteristics. The effect of the chemical cleaning procedures was found to be more significant on CNT-metal contacts than for the FET channels. Moreover, we investigated the effect of an additional thermal cleaning step under vacuum after the chemical cleaning, which had an exceptional impact on the hysteresis behavior including hysteresis reversal. The presence of surfactant molecules on CNT was evidenced by X-ray photoelectron and Raman spectroscopies. By identifying the role of surfactant molecules and assessing the enhancement of device performance as a direct consequence of several cleaning procedures, these results are important for the development of CNT-based electronics at the wafer-level.« less
NASA Astrophysics Data System (ADS)
Tittmann-Otto, J.; Hermann, S.; Kalbacova, J.; Hartmann, M.; Toader, M.; Rodriguez, R. D.; Schulz, S. E.; Zahn, D. R. T.; Gessner, T.
2016-03-01
The interface between a carbon nanotube (CNT) and its environment can dramatically affect the electrical properties of CNT-based field-effect transistors (FETs). For such devices, the channel environment plays a significant role inducing doping or charge traps giving rise to hysteresis in the transistor characteristics. Thereby the fabrication process strongly determines the extent of those effects and the final device performance. In CNT-based devices obtained from dispersions, a proper individualization of the nanotubes is mandatory. This is generally realized by an ultrasonic treatment combined with surfactant molecules, which enwrap nanotubes forming micelle aggregates. To minimize impact on device performance, it is of vital importance to consider post-deposition treatments for removal of surfactant molecules and other impurities. In this context, we investigated the effect of several wet chemical cleaning and thermal post treatments on the electrical characteristics as well as physical properties of more than 600 devices fabricated only by wafer-level compatible technologies. We observed that nitric acid and water treatments improved the maximum-current of devices. Additionally, we found that the ethanol treatment successfully lowered hysteresis in the transfer characteristics. The effect of the chemical cleaning procedures was found to be more significant on CNT-metal contacts than for the FET channels. Moreover, we investigated the effect of an additional thermal cleaning step under vacuum after the chemical cleaning, which had an exceptional impact on the hysteresis behavior including hysteresis reversal. The presence of surfactant molecules on CNT was evidenced by X-ray photoelectron and Raman spectroscopies. By identifying the role of surfactant molecules and assessing the enhancement of device performance as a direct consequence of several cleaning procedures, these results are important for the development of CNT-based electronics at the wafer-level.
Alam, Mian Bilal; Munir, Muhammad Bilal; Rattan, Rohit; Adelstein, Evan; Jain, Sandeep; Saba, Samir
2017-03-01
Cardiac resynchronization therapy (CRT) is an important treatment for heart failure that requires constant ventricular pacing, placing a high energy burden on CRT defibrillators (CRT-D). Longer battery life reduces the need for device changes and associated complications, thereby affecting patient outcomes and cost of care. We therefore investigated the time to battery depletion of CRT-D from different manufacturers and compared these results with manufacturers' published product performance reports (PPRs). All CRT-D recipients at our institution between January 2008 and December 2010 were included in this study cohort. The patients were followed up to the endpoint of battery depletion and were otherwise censored at the time of death, last follow-up, or device removal for any reason other than battery depletion. A total of 621 patients [173 Boston Scientific (BSC), 391 Medtronic (MDT), and 57 St. Jude Medical (SJM)] were followed up for a median of 3.7 (IQR 1.6-5.0) years, during which time 253 (41%) devices were replaced for battery depletion. Compared with MDT devices, battery depletion was 85 and 54% less likely to happen with BSC and SJM devices, respectively (P < 0.001 for pairwise comparisons). Product performance reports from all manufacturers significantly overestimated battery longevity by more than 20% 6 years after device implantation. Large differences in CRT-D battery longevity exist between manufacturers. Industry-published PPRs significantly overestimate device longevity. These data have important implications to patients, healthcare professionals, hospitals, and third-party payers. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Dwivedi, Prashant Povel; Kumar, Challa Sesha Sai Pavan; Choi, Hee Joo; Cha, Myoungsik
2016-02-01
Random duty-cycle error (RDE) is inherent in the fabrication of ferroelectric quasi-phase-matching (QPM) gratings. Although a small RDE may not affect the nonlinearity of QPM devices, it enhances non-phase-matched parasitic harmonic generations, limiting the device performance in some applications. Recently, we demonstrated a simple method for measuring the RDE in QPM gratings by analyzing the far-field diffraction pattern obtained by uniform illumination (Dwivedi et al. in Opt Express 21:30221-30226, 2013). In the present study, we used a Gaussian beam illumination for the diffraction experiment to measure noise spectra that are less affected by the pedestals of the strong diffraction orders. Our results were compared with our calculations based on a random grating model, demonstrating improved resolution in the RDE estimation.
A "place n play" modular pump for portable microfluidic applications.
Li, Gang; Luo, Yahui; Chen, Qiang; Liao, Lingying; Zhao, Jianlong
2012-03-01
This paper presents an easy-to-use, power-free, and modular pump for portable microfluidic applications. The pump module is a degassed particle desorption polydimethylsiloxane (PDMS) slab with an integrated mesh-shaped chamber, which can be attached on the outlet port of microfluidic device to absorb the air in the microfluidic system and then to create a negative pressure for driving fluid. Different from the existing monolithic degassed PDMS pumps that are generally restricted to limited pumping capacity and are only compatible with PDMS-based microfluidic devices, this pump can offer various possible configures of pumping power by varying the geometries of the pump or by combining different pump modules and can also be employed in any material microfluidic devices. The key advantage of this pump is that its operation only requires the user to place the degassed PDMS slab on the outlet ports of microfluidic devices. To help design pumps with a suitable pumping performance, the effect of pump module geometry on its pumping capacity is also investigated. The results indicate that the performance of the degassed PDMS pump is strongly dependent on the surface area of the pump chamber, the exposure area and the volume of the PDMS pump slab. In addition, the initial volume of air in the closed microfluidic system and the cross-linking degree of PDMS also affect the performance of the degassed PDMS pump. Finally, we demonstrated the utility of this modular pumping method by applying it to a glass-based microfluidic device and a PDMS-based protein crystallization microfluidic device.
A “place n play” modular pump for portable microfluidic applications
Li, Gang; Luo, Yahui; Chen, Qiang; Liao, Lingying; Zhao, Jianlong
2012-01-01
This paper presents an easy-to-use, power-free, and modular pump for portable microfluidic applications. The pump module is a degassed particle desorption polydimethylsiloxane (PDMS) slab with an integrated mesh-shaped chamber, which can be attached on the outlet port of microfluidic device to absorb the air in the microfluidic system and then to create a negative pressure for driving fluid. Different from the existing monolithic degassed PDMS pumps that are generally restricted to limited pumping capacity and are only compatible with PDMS-based microfluidic devices, this pump can offer various possible configures of pumping power by varying the geometries of the pump or by combining different pump modules and can also be employed in any material microfluidic devices. The key advantage of this pump is that its operation only requires the user to place the degassed PDMS slab on the outlet ports of microfluidic devices. To help design pumps with a suitable pumping performance, the effect of pump module geometry on its pumping capacity is also investigated. The results indicate that the performance of the degassed PDMS pump is strongly dependent on the surface area of the pump chamber, the exposure area and the volume of the PDMS pump slab. In addition, the initial volume of air in the closed microfluidic system and the cross-linking degree of PDMS also affect the performance of the degassed PDMS pump. Finally, we demonstrated the utility of this modular pumping method by applying it to a glass-based microfluidic device and a PDMS-based protein crystallization microfluidic device. PMID:22685507
Mobility and orientation aid for blind persons using artificial vision
NASA Astrophysics Data System (ADS)
Costa, Gustavo; Gusberti, Adrián; Graffigna, Juan Pablo; Guzzo, Martín; Nasisi, Oscar
2007-11-01
Blind or vision-impaired persons are limited in their normal life activities. Mobility and orientation of blind persons is an ever-present research subject because no total solution has yet been reached for these activities that pose certain risks for the affected persons. The current work presents the design and development of a device conceived on capturing environment information through stereoscopic vision. The images captured by a couple of video cameras are transferred and processed by configurable and sequential FPGA and DSP devices that issue action signals to a tactile feedback system. Optimal processing algorithms are implemented to perform this feedback in real time. The components selected permit portability; that is, to readily get used to wearing the device.
Reticle variation influence on manufacturing line and wafer device performance
NASA Astrophysics Data System (ADS)
Nistler, John L.; Spurlock, Kyle
1994-01-01
Cost effective manufacturing of devices at 0.5, 0.35 and 0.25μm geometries will be highly dependent on a companys' ability to obtain an economic return on investment. The high capital investment in equipment and facilities, not to mention the related chemical and wafer costs, for producing 200mm silicon wafers requires aspects of wafer processing to be tightly controlled. Reduction in errors and enhanced yield management requires early correction or avoidance of reticle problems. It is becoming increasingly important to recognize and track all pertinent factors impacting both the technical and financial viability of a wafer manufacturing fabrication area. Reticle related effects on wafer manufacturing can be costly and affect the total quality perceived by the device customer.
Ultra-slim flexible glass for roll-to-roll electronic device fabrication
NASA Astrophysics Data System (ADS)
Garner, Sean; Glaesemann, Scott; Li, Xinghua
2014-08-01
As displays and electronics evolve to become lighter, thinner, and more flexible, the choice of substrate continues to be critical to their overall optimization. The substrate directly affects improvements in the designs, materials, fabrication processes, and performance of advanced electronics. With their inherent benefits such as surface quality, optical transmission, hermeticity, and thermal and dimensional stability, glass substrates enable high-quality and long-life devices. As substrate thicknesses are reduced below 200 μm, ultra-slim flexible glass continues to provide these inherent benefits to high-performance flexible electronics such as displays, touch sensors, photovoltaics, and lighting. In addition, the reduction in glass thickness also allows for new device designs and high-throughput, continuous manufacturing enabled by R2R processes. This paper provides an overview of ultra-slim flexible glass substrates and how they enable flexible electronic device optimization. Specific focus is put on flexible glass' mechanical reliability. For this, a combination of substrate design and process optimizations has been demonstrated that enables R2R device fabrication on flexible glass. Demonstrations of R2R flexible glass processes such as vacuum deposition, photolithography, laser patterning, screen printing, slot die coating, and lamination have been made. Compatibility with these key process steps has resulted in the first demonstration of a fully functional flexible glass device fabricated completely using R2R processes.
NASA Astrophysics Data System (ADS)
Gamzina, Diana
Diana Gamzina March 2016 Mechanical and Aerospace Engineering Multiscale Thermo-Mechanical Design and Analysis of High Frequency and High Power Vacuum Electron Devices Abstract A methodology for performing thermo-mechanical design and analysis of high frequency and high average power vacuum electron devices is presented. This methodology results in a "first-pass" engineering design directly ready for manufacturing. The methodology includes establishment of thermal and mechanical boundary conditions, evaluation of convective film heat transfer coefficients, identification of material options, evaluation of temperature and stress field distributions, assessment of microscale effects on the stress state of the material, and fatigue analysis. The feature size of vacuum electron devices operating in the high frequency regime of 100 GHz to 1 THz is comparable to the microstructure of the materials employed for their fabrication. As a result, the thermo-mechanical performance of a device is affected by the local material microstructure. Such multiscale effects on the stress state are considered in the range of scales from about 10 microns up to a few millimeters. The design and analysis methodology is demonstrated on three separate microwave devices: a 95 GHz 10 kW cw sheet beam klystron, a 263 GHz 50 W long pulse wide-bandwidth sheet beam travelling wave tube, and a 346 GHz 1 W cw backward wave oscillator.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Varley, J. B.; Conway, A. M.; Voss, L. F.
Thallium bromide (TlBr) crystals subjected to hydrochloric acid (HCl) chemical treatments have been shown to advantageously affect device performance and longevity in TlBr-based room temperature radiation detectors, yet the exact mechanisms of the improvements remain poorly understood. Here in this paper, we investigate the influence of several HCl chemical treatments on device-grade TlBr and describe the changes in the composition and electronic structure of the surface. Composition analysis and depth profiles obtained from secondary ion mass spectrometry (SIMS) identify the extent to which each HCl etch condition affects the detector surface region and forms of a graded TlBr/TlBr 1-xCL xmore » surface heterojunction. Using a combination of X-ray photoemission spectroscopy (XPS) and hybrid density functional calculations, we are able to determine the valence band offsets, band gaps, and conduction band offsets as a function of Cl content over the entire composition range of TIBr 1-xC1 X. This study establishes a strong correlation between device process conditions, surface chemistry, and electronic structure with the goal of further optimizing the long-term stability and radiation response of TlBr-based detectors.« less
Effects of Contact-Induced Doping on the Behaviors of Organic Photovoltaic Devices
Wang, Jian; Xu, Liang; Lee, Yun -Ju; ...
2015-10-09
Substrates can significantly affect the electronic properties of organic semiconductors. In this paper, we report the effects of contact-induced doping, arising from charge transfer between a high work function hole extraction layer (HEL) and the organic active layer, on organic photovoltaic device performance. Employing a high work function HEL is found to increase doping in the active layer and decrease photocurrent. Combined experimental and modeling investigations reveal that higher doping increases polaron–exciton quenching and carrier recombination within the field-free region. Consequently, there exists an optimal HEL work function that enables a large built-in field while keeping the active layer dopingmore » low. This value is found to be ~0.4 eV larger than the pinning level of the active layer material. As a result, these understandings establish a criterion for optimal design of the HEL when adapting a new active layer system and can shed light on optimizing performance in other organic electronic devices.« less
Optical silicones for use in harsh operating environments
NASA Astrophysics Data System (ADS)
Riegler, Bill; Bruner, Stephen J.; Elgin, Randall
2004-12-01
The optics industry widely uses silcones for various fiber optic cable potting applications and light emitting diode protection. Optics manufacturers know traditional silicone elastomers, gels, thixotropic gels, and fluids not only perform extremely well in high temperature applications, but also offer refractive index matching so that silicones can transmit light with admirable efficiency. However, because environmental conditions may affect a material's performance over time, one must also consider the conditions the device operates in to ensure long-term reliability. External environments may include exposure to a combination of UV light and temperature, while other environments may expose devices to hydrocarbon based fuels. This paper will delve into the chemistry of silicones and functional groups that lend themselves to properties such as temperature, fuel, and radiation resistance to show shy silicone is the material of choice for optic applications under normally harmful forms of exposure. Data will be presented to examine silicone's performance in these environment.
Tan, Michael Loong Peng; Lentaris, Georgios; Amaratunga Aj, Gehan
2012-08-19
The performance of a semiconducting carbon nanotube (CNT) is assessed and tabulated for parameters against those of a metal-oxide-semiconductor field-effect transistor (MOSFET). Both CNT and MOSFET models considered agree well with the trends in the available experimental data. The results obtained show that nanotubes can significantly reduce the drain-induced barrier lowering effect and subthreshold swing in silicon channel replacement while sustaining smaller channel area at higher current density. Performance metrics of both devices such as current drive strength, current on-off ratio (Ion/Ioff), energy-delay product, and power-delay product for logic gates, namely NAND and NOR, are presented. Design rules used for carbon nanotube field-effect transistors (CNTFETs) are compatible with the 45-nm MOSFET technology. The parasitics associated with interconnects are also incorporated in the model. Interconnects can affect the propagation delay in a CNTFET. Smaller length interconnects result in higher cutoff frequency.
Carbon Based Transistors and Nanoelectronic Devices
NASA Astrophysics Data System (ADS)
Rouhi, Nima
Carbon based materials (carbon nanotube and graphene) has been extensively researched during the past decade as one of the promising materials to be used in high performance device technology. In long term it is thought that they may replace digital and/or analog electronic devices, due to their size, near-ballistic transport, and high stability. However, a more realistic point of insertion into market may be the printed nanoelectronic circuits and sensors. These applications include printed circuits for flexible electronics and displays, large-scale bendable electrical contacts, bio-membranes and bio sensors, RFID tags, etc. In order to obtain high performance thin film transistors (as the basic building block of electronic circuits) one should be able to manufacture dense arrays of all semiconducting nanotubes. Besides, graphene synthesize and transfer technology is in its infancy and there is plenty of room to improve the current techniques. To realize the performance of nanotube and graphene films in such systems, we need to economically fabricate large-scale devices based on these materials. Following that the performance control over such devices should also be considered for future design variations for broad range of applications. Here we have first investigated carbon nanotube ink as the base material for our devices. The primary ink used consisted of both metallic and semiconducting nanotubes which resulted in networks suitable for moderate-resistivity electrical connections (such as interconnects) and rfmatching circuits. Next, purified all-semiconducting nanotube ink was used to fabricate waferscale, high performance (high mobility, and high on/off ratio) thin film transistors for printed electronic applications. The parameters affecting device performance were studied in detail to establish a roadmap for the future of purified nanotube ink printed thin film transistors. The trade of between mobility and on/off ratio of such devices was studied and the effect of nanotube network density was explained in detail. On the other hand, graphene transfer technology was explored here as well. Annealing techniques were utilized to deposit clean graphene on arbitrary substrates. Raman spectroscopy and Raman data analysis was used to confirm the clean process. Furthermore, suspended graphene membrane was fabricated using single and multi-layer graphene films. This can make a major impact on graphene based transistors and bio-nano sensors technology.
An MRF-based device for the torque stiffness control of all movable vertical tails
NASA Astrophysics Data System (ADS)
Ameduri, Salvatore; Concilio, Antonio; Gianvito, Antonio; Lemme, Manuel
2005-05-01
Aerodynamic control surfaces efficiency is among the major parameters defining the performance of generic aircraft and is strongly affected by geometric and stiffness characteristics. A target of the '3AS' European Project is to estimate the eventual benefits coming from the adaptive control of the torque rigidity of the vertical tail of the EuRAM wind tunnel model. The specific role of CIRA inside the Project is the design of a device based on the "Smart Structures and Materials" concept, able to produce required stiffness variations. Numerical and experimental investigations pointed out that wide excursions of the tail torque rigidity may assure higher efficiency, for several flight regimes. Stiffness variations may be obtained through both classical mechanic-hydraulic and smart systems. In this case, the attainable weight and reliability level may be the significant parameters to drive the choice. For this reason, CIRA focused its efforts also on the design of devices without heavy mechanical parts. The device described in this work is schematically constituted by linear springs linked in a suitably way to the tail shaft. Required stiffness variations are achieved by selectively locking one or more springs, through a hydraulic system, MRF-based. An optimisation process was performed to find the spring features maximising the achievable stiffness range. Then, the hydraulic MRF design was dealt with. Finally, basing on numerical predictions, a prototype was manufactured and an experimental campaign was performed to estimate the device static and dynamic behaviour.
The role of visual deprivation and experience on the performance of sensory substitution devices.
Stronks, H Christiaan; Nau, Amy C; Ibbotson, Michael R; Barnes, Nick
2015-10-22
It is commonly accepted that the blind can partially compensate for their loss of vision by developing enhanced abilities with their remaining senses. This visual compensation may be related to the fact that blind people rely on their other senses in everyday life. Many studies have indeed shown that experience plays an important role in visual compensation. Numerous neuroimaging studies have shown that the visual cortices of the blind are recruited by other functional brain areas and can become responsive to tactile or auditory input instead. These cross-modal plastic changes are more pronounced in the early blind compared to late blind individuals. The functional consequences of cross-modal plasticity on visual compensation in the blind are debated, as are the influences of various etiologies of vision loss (i.e., blindness acquired early or late in life). Distinguishing between the influences of experience and visual deprivation on compensation is especially relevant for rehabilitation of the blind with sensory substitution devices. The BrainPort artificial vision device and The vOICe are assistive devices for the blind that redirect visual information to another intact sensory system. Establishing how experience and different etiologies of vision loss affect the performance of these devices may help to improve existing rehabilitation strategies, formulate effective selection criteria and develop prognostic measures. In this review we will discuss studies that investigated the influence of training and visual deprivation on the performance of various sensory substitution approaches. Copyright © 2015 Elsevier B.V. All rights reserved.
Temperature Dependence of Photoluminescence in InGaAs/InP Strained MQW Heterostructures
NASA Technical Reports Server (NTRS)
Raisky, O. Y.; Wang, W. B.; Alfano, R. R.; Reynolds, C. L., Jr.; Swaminathan, V.
1996-01-01
Multiple quantum well (MQW) InGaAsP/InP heterostructure systems have been drawn considerable research interest in recent years due to its suitability for long wavelength optoelectronic devices. The performance of such devices is strongly affected by peculiarities of recombination processes in the quantum wells (QW). The goal of this study was to investigate the effect of barrier width on the radiative recombination of carriers. In our study, the photoluminescence spectra from InGaAsP/lnP MQW double heterostructures have been measured in the 77-290 K temperature range with different excitation intensities.
Evaluation of flip-flop jet nozzles for use as practical excitation devices
NASA Technical Reports Server (NTRS)
Raman, Ganesh; Rice, Edward J.; Cornelius, David M.
1994-01-01
This paper describes the flowfield characteristics of the flip-flop jet nozzle and the potential for using this nozzle as a practical excitation device. It appears from the existing body of published information that there is a lack of data on the parameters affecting the operation of such nozzles and on the mechanism of operation of these nozzles. An attempt is made in the present work to study the important parameters affecting the operation and performance of a flip-flop jet nozzle. Measurements were carried out to systematically assess the effect of varying the nozzle pressure ratio (NPR) as well as the length and volume of the feedback tube on the frequency of oscillation of this device. Flow visualization was used to obtain a better understanding of the jet flowfield and of the processes occurring within the feedback tube. The frequency of oscillation of the flip-flop jet depended significantly on the feedback tube length and volume as well as on the nozzle pressure ratio. In contrast, the coherent velocity perturbation levels did not depend on the above mentioned parameters. The data presented in this paper would be useful for modeling such flip-flop excitation devices that are potentially useful for controlling practical shear flows.
Giesbrecht, Ed M; Ripat, Jacquie D; Cooper, Juliette E; Quanbury, Arthur O
2011-04-01
Occupational therapists strive to engage individuals in occupation and enhance community access through wheelchair prescription. Previous research with pushrim-activated, power-assisted wheelchairs identifies a reduction in the physical demands of manual wheelchair propulsion but limited evidence exists regarding user evaluation in context. This study explored the experience of using a power-assisted wheelchair in the community. Eight individuals who used both a power and manual device participated in focus groups after trialing a power-assist wheelchair for three weeks. Data were analyzed using a qualitative description approach. Three themes emerged from our analysis: relative advantages and disadvantages; environmental factors that affect accessibility; and evaluation of mobility device. Participants perceived the power-assist as improving performance and accessibility compared with the manual wheelchair, increasing the potential scope of occupations and environments, but not replacing their power mobility device. Sufficient time for adjustment of both user and device was important.
NASA Technical Reports Server (NTRS)
Kadivar, Zahra; Beck, Christopher E.; Rovekamp, Roger N.; O'Malley, Marcia K.; Joyce, Charles A.
2016-01-01
Treatment intensity has a profound effect on motor recovery following neurological injury. The use of robotics has potential to automate these labor-intensive therapy procedures that are typically performed by physical therapists. Further, the use of wearable robotics offers an aspect of portability that may allow for rehabilitation outside the clinic. The authors have developed a soft, portable, lightweight upper extremity wearable robotic device to provide motor rehabilitation of patients with affected upper limbs due to traumatic brain injury (TBI). A key feature of the device demonstrated in this paper is the isolation of shoulder and elbow movements necessary for effective rehabilitation interventions. Herein is presented a feasibility study with one subject and demonstration of the device's ability to provide safe, comfortable, and controlled upper extremity movements. Moreover, it is shown that by decoupling shoulder and elbow motions, desired isolated joint actuation can be achieved.
Small area silicon diffused junction X-ray detectors
NASA Technical Reports Server (NTRS)
Walton, J. T.; Pehl, R. H.; Larsh, A. E.
1982-01-01
The low-temperature performance of silicon diffused junction detectors in the measurement of low energy X-rays is reported. The detectors have an area of 0.04 sq cm and a thickness of 100 microns. The spectral resolutions of these detectors were found to be in close agreement with expected values, indicating that the defects introduced by the high-temperature processing required in the device fabrication were not deleteriously affecting the detection of low-energy X-rays. Device performance over a temperature range of 77 K to 150 K is given. These detectors were designed to detect low-energy X-rays in the presence of minimum ionizing electrons. The successful application of silicon-diffused junction technology to X-ray detector fabrication may facilitate the development of other novel silicon X-ray detector designs.
The use of piezosurgery in cranial surgery in children.
Ramieri, Valerio; Saponaro, Gianmarco; Lenzi, Jacopo; Caporlingua, Federico; Polimeni, Antonella; Silvestri, Alessandro; Pizzuti, Antonio; Roggini, Mario; Tarani, Luigi; Papoff, Paola; Giancotti, Antonella; Castori, Marco; Manganaro, Lucia; Cascone, Piero; Piero, Cascone
2015-05-01
Piezosurgery is an alternative surgical technique, now widely tested, that uses ultrasounds for bone cutting. This device uses ultrasounds to section hard tissues without harming surrounding soft tissues. The authors analyzed their experience in craniomaxillofacial procedures with piezosurgery. A comparison between operation timing and complication rates between piezosurgery and traditional cutting instruments has been performed. A total of 27 patients were examined (15 females and 12 males; average age, of 5.5 months) affected by craniosynostosis. The aim of this study was to analyze the advantages and disadvantages of piezosurgery in pediatric craniofacial procedures. Piezoelectric device in this study has shown being a valid instrument for bone cutting in accurate procedures, because it allows performing a more precise and safer cutting, without the risk of harming surrounding tissues.
Transparent resistive switching memory using aluminum oxide on a flexible substrate
NASA Astrophysics Data System (ADS)
Yeom, Seung-Won; Shin, Sang-Chul; Kim, Tan-Young; Ha, Hyeon Jun; Lee, Yun-Hi; Shim, Jae Won; Ju, Byeong-Kwon
2016-02-01
Resistive switching memory (ReRAM) has attracted much attention in recent times owing to its fast switching, simple structure, and non-volatility. Flexible and transparent electronic devices have also attracted considerable attention. We therefore fabricated an Al2O3-based ReRAM with transparent indium-zinc-oxide (IZO) electrodes on a flexible substrate. The device transmittance was found to be higher than 80% in the visible region (400-800 nm). Bended states (radius = 10 mm) of the device also did not affect the memory performance because of the flexibility of the two transparent IZO electrodes and the thin Al2O3 layer. The conduction mechanism of the resistive switching of our device was explained by ohmic conduction and a Poole-Frenkel emission model. The conduction mechanism was proved by oxygen vacancies in the Al2O3 layer, as analyzed by x-ray photoelectron spectroscopy analysis. These results encourage the application of ReRAM in flexible and transparent electronic devices.
Weksler, Marc E; Weksler, Babette B
2012-01-01
Multitasking is a rapidly growing phenomenon affecting all segments of the population but is rarely as successful as its proponents believe. The use of mobile electronic devices contributes importantly to multitasking and cognitive overload. Although personal electronic devices provide many benefits, their adverse effects are frequently overlooked. Personal observation and a review of the scientific literature supports the view that overuse or misuse of personal electronic devices promotes cognitive overload, impairs multitasking and lowers performance at all ages but particularly in the elderly. This phenomenon appears to be rapidly increasing and threatens to become a tsunami as spreading electronic waves cause an 'epidemic of distraction'. Mobile electronic devices often bring benefits to their users in terms of rapid access to information. However, there is a dark side to the increasing addiction to these devices that challenges the health and well-being of the entire population, targeting, in particular, the aged and infirm. New approaches to information gathering can foster creativity if cognitive overload is avoided. Copyright © 2012 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Chang, Tien-Li; Chen, Zhao-Chi
2015-12-01
The study presents a direct process for surface patterning of multilayer graphene on the glass substrate as a biosensing device. In contrast to lithography with etching, the proposed process provides simultaneous surface patterning of multilayer graphene through nanosecond laser irradiation. In this study, the multilayer graphene was prepared by a screen printing process. Additionally, the wavelength of the laser beam was 355 nm. To perform the effective laser process with the small heat affected zone, the surface patterns on the sensing devices could be directly fabricated using the laser with optimal control of the pulse overlap at a fluence threshold of 0.63 J/cm2. The unique patterning of the laser-ablated surface exhibits their electrical and hydrophilic characteristics. The hydrophilic surface of graphene-based sensing devices was achieved in the process with the pulse overlap of 90%. Furthermore, the sensing devices for controlling the electrical response of glucose by using glucose oxidase can be used in sensors in commercial medical applications.
Jones, Maddison J; Peeling, Peter; Dawson, Brian; Halson, Shona; Miller, Joanna; Dunican, Ian; Clarke, Michael; Goodman, Carmel; Eastwood, Peter
2018-01-01
The aim of the present study was to investigate the influence of different types of tasks performed with or without an electronic device (tablet) on pre-sleep alertness, subsequent sleep quality and next-day athletic performance. Eight highly trained netball players attended a sleep laboratory for pre-sleep testing, polysomnographic sleep monitoring and next-day physical performance testing on 5 separate occasions (1 familiarisation and 4 experimental sessions). For 2 h prior to bedtime, athletes completed cognitively stimulating tasks (puzzles) or passive tasks (reading) with or without a tablet. Sleepiness tended to be greater after reading compared to completing puzzles without a tablet (d = 0.80), but not with a tablet. Melatonin concentration increased more so after reading compared to completing puzzles on a tablet (P = 0.02). There were no significant differences in sleep quality or quantity or next-day athletic performance between any of the conditions. These data suggest that using a tablet for 2 h prior to sleep does not negatively affect subsequent sleep or next-day performance in athletes.
Neuromorphic Learning From Noisy Data
NASA Technical Reports Server (NTRS)
Merrill, Walter C.; Troudet, Terry
1993-01-01
Two reports present numerical study of performance of feedforward neural network trained by back-propagation algorithm in learning continuous-valued mappings from data corrupted by noise. Two types of noise considered: plant noise which affects dynamics of controlled process and data-processing noise, which occurs during analog processing and digital sampling of signals. Study performed with view toward use of neural networks as neurocontrollers to substitute for, or enhance, performances of human experts in controlling mechanical devices in presence of sensor and actuator noise and to enhance performances of more-conventional digital feedback electronic process controllers in noisy environments.
Evaluation of control and display configurations for helicopter shipboard operations
NASA Technical Reports Server (NTRS)
Paulk, C. H., Jr.; Donley, S. T.; Hollis, M. K.
1983-01-01
A simulation evaluation of several approach and landing flight-control configurations and of two out-of-the-cockpit display devices (a head-up display and a helmet-mounted display) was performed for the task of landing a helicopter on a destroyer in adverse weather. The results indicated that the ship airwake turbulence was the most significant environmental variable affecting hover performance. In addition, to achieve adequate landing performance, attitude-command control compensation was required for the pilot regardless of the display used. For improved performance with reduced pilot effort, a velocity-command, position-hold control system was desired.
Performance Gains of Propellant Management Devices for Liquid Hydrogen Depots
NASA Technical Reports Server (NTRS)
Hartwig, Jason W.; McQuillen, John B.; Chato, David J.
2013-01-01
This paper presents background, experimental design, and preliminary experimental results for the liquid hydrogen bubble point tests conducted at the Cryogenic Components Cell 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. The purpose of the test series was to investigate the parameters that affect liquid acquisition device (LAD) performance in a liquid hydrogen (LH2) propellant tank, to mitigate risk in the final design of the LAD for the Cryogenic Propellant Storage and Transfer Technology Demonstration Mission, and to provide insight into optimal LAD operation for future LH2 depots. Preliminary test results show an increase in performance and screen retention over the low reference LH2 bubble point value for a 325 2300 screen in three separate ways, thus improving fundamental LH2 LAD performance. By using a finer mesh screen, operating at a colder liquid temperature, and pressurizing with a noncondensible pressurant gas, a significant increase in margin is achieved in bubble point pressure for LH2 screen channel LADs.
Latzel, M; Büttner, P; Sarau, G; Höflich, K; Heilmann, M; Chen, W; Wen, X; Conibeer, G; Christiansen, S H
2017-02-03
Nanotextured surfaces provide an ideal platform for efficiently capturing and emitting light. However, the increased surface area in combination with surface defects induced by nanostructuring e.g. using reactive ion etching (RIE) negatively affects the device's active region and, thus, drastically decreases device performance. In this work, the influence of structural defects and surface states on the optical and electrical performance of InGaN/GaN nanorod (NR) light emitting diodes (LEDs) fabricated by top-down RIE of c-plane GaN with InGaN quantum wells was investigated. After proper surface treatment a significantly improved device performance could be shown. Therefore, wet chemical removal of damaged material in KOH solution followed by atomic layer deposition of only 10 [Formula: see text] alumina as wide bandgap oxide for passivation were successfully applied. Raman spectroscopy revealed that the initially compressively strained InGaN/GaN LED layer stack turned into a virtually completely relaxed GaN and partially relaxed InGaN combination after RIE etching of NRs. Time-correlated single photon counting provides evidence that both treatments-chemical etching and alumina deposition-reduce the number of pathways for non-radiative recombination. Steady-state photoluminescence revealed that the luminescent performance of the NR LEDs is increased by about 50% after KOH and 80% after additional alumina passivation. Finally, complete NR LED devices with a suspended graphene contact were fabricated, for which the effectiveness of the alumina passivation was successfully demonstrated by electroluminescence measurements.
Haggerty, Christopher M; Fynn-Thompson, Francis; McElhinney, Doff B; Valente, Anne Marie; Saikrishnan, Neelakantan; Del Nido, Pedro J; Yoganathan, Ajit P
2012-09-01
This study sought to evaluate the performance of microaxial ventricular assist devices for the purposes of supporting failing Fontan physiology by decreasing central venous pressure. Three Abiomed Impella pumps (Abiomed, Inc, Danvers, Mass) were evaluated in a mock circulatory system of the Fontan circuit. The local response of pressures and flows to pump function was assessed as a function of pump speed and pulmonary vascular resistance at a high baseline central venous pressure. For one device, subsequent modeling studies were conducted using a lumped parameter model of the single ventricle circuit. The left ventricular devices (Impella 2.5, 5.0) were shown to be suboptimal as single device solutions for cavopulmonary support. The small area of these devices relative to vessel diameter led to significant flow recirculation without an obstructive separator in place. Furthermore, downstream pressure augmentation adversely affected the pressure in the superior vena cava. The use of 2 devices would be mandatory for successful support. The right-sided device (Impella RP), whose outflow was positioned in the left pulmonary artery, demonstrated decreased flow recirculation and did not impede superior caval venous flow. Although static pressure is still required to drive flow through the opposite lung, numeric modeling demonstrated the potential for modest but significant improvements in lowering the central venous pressure (2-8 mm Hg). Left-sided microaxial pumps are not well suited for cavopulmonary support because of severe flow recirculation and the need for multiple devices. The right-ventricular Impella device provides improved performance by directing flow into the pulmonary artery, resulting in modest decreases in central venous pressure. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
INTEGRATING DATA ANALYTICS AND SIMULATION METHODS TO SUPPORT MANUFACTURING DECISION MAKING
Kibira, Deogratias; Hatim, Qais; Kumara, Soundar; Shao, Guodong
2017-01-01
Modern manufacturing systems are installed with smart devices such as sensors that monitor system performance and collect data to manage uncertainties in their operations. However, multiple parameters and variables affect system performance, making it impossible for a human to make informed decisions without systematic methodologies and tools. Further, the large volume and variety of streaming data collected is beyond simulation analysis alone. Simulation models are run with well-prepared data. Novel approaches, combining different methods, are needed to use this data for making guided decisions. This paper proposes a methodology whereby parameters that most affect system performance are extracted from the data using data analytics methods. These parameters are used to develop scenarios for simulation inputs; system optimizations are performed on simulation data outputs. A case study of a machine shop demonstrates the proposed methodology. This paper also reviews candidate standards for data collection, simulation, and systems interfaces. PMID:28690363
Molecular Strategies for Morphology Control in Semiconducting Polymers for Optoelectronics.
Rahmanudin, Aiman; Sivula, Kevin
2017-06-28
Solution-processable semiconducting polymers have been explored over the last decades for their potential applications in inexpensively fabricated transistors, diodes and photovoltaic cells. However, a remaining challenge in the field is to control the solid-state self-assembly of polymer chains in thin films devices, as the aspects of (semi)crystallinity, grain boundaries, and chain entanglement can drastically affect intra-and inter-molecular charge transport/transfer and thus device performance. In this short review we examine how the aspects of molecular weight and chain rigidity affect solid-state self-assembly and highlight molecular engineering strategies to tune thin film morphology. Side chain engineering, flexibly linking conjugation segments, and block co-polymer strategies are specifically discussed with respect to their effect on field effect charge carrier mobility in transistors and power conversion efficiency in solar cells. Example systems are taken from recent literature including work from our laboratories to illustrate the potential of molecular engineering semiconducting polymers.
Investigations on response time of magnetorheological elastomer under compression mode
NASA Astrophysics Data System (ADS)
Zhu, Mi; Yu, Miao; Qi, Song; Fu, Jie
2018-05-01
For efficient fast control of vibration system with magnetorheological elastomer (MRE)-based smart device, the response time of MRE material is the key parameter which directly affects the control performance of the vibration system. For a step coil current excitation, this paper proposed a Maxwell behavior model with time constant λ to describe the normal force response of MRE, and the response time of MRE was extracted through the separation of coil response time. Besides, the transient responses of MRE under compression mode were experimentally investigated, and the effects of (i) applied current, (ii) particle distribution and (iii) compressive strain on the response time of MRE were addressed. The results revealed that the three factors can affect the response characteristic of MRE quite significantly. Besides the intrinsic importance for contributing to the response evaluation and effective design of MRE device, this study may conduce to the optimal design of controller for MRE control system.
Fabrication of solar beam steering electrowetting devices—present status and future prospects
NASA Astrophysics Data System (ADS)
Khan, I.; Castelletto, S.; Rosengarten, G.
2017-10-01
Many different technologies are used to track the movement of the sun to both enable concentration of its energy and maximize the yearly energy capture. Their present main limitations are the cost, size, visual impact and wind loading, particularly for applications involving mounting to a building. A parabolic concentrator, for example, along with its steering equipment is heavy and bulky, and is not suitable for rooftop applications. Instead, thin and flat solar concentration devices are required for hassle-free rooftop applications. The use of electrowetting-controlled liquid lenses has emerged as a novel approach for solar tracking and concentration. By steering sunlight using thin electrowetting cell arrays, bulky mechanical equipment is not required. The basic concept of this technology is to change the shape of a liquid interface that is formed by two immiscible fluids of different refractive indices, by simply applying an electric field. An important challenge in electrowetting beam steering devices is the optimization of the design and fabrication process for each of their main constituent components, to maximize optical efficiency. In this paper, we report on the state-of-the-art fabrication methods for electrowetting devices for solar beam steering. We have reviewed the present status of different components types and related fabrication methods, and how they affect the efficiency and performance of such devices. The work identifies future prospects in using electrowetting beam steering devices for solar energy applications. This paper will help researchers and developers in the field to determine the components and fabrication process that affect the development of efficient beam steering electrowetting devices.
Degree of bioresorbable vascular scaffold expansion modulates loss of essential function.
Ferdous, Jahid; Kolachalama, Vijaya B; Kolandaivelu, Kumaran; Shazly, Tarek
2015-10-01
Drug-eluting bioresorbable vascular scaffolds (BVSs) have the potential to restore lumen patency, enable recovery of the native vascular environment, and circumvent late complications associated with permanent endovascular devices. To ensure therapeutic effects persist for sufficient times prior to scaffold resorption and resultant functional loss, many factors dictating BVS performance must be identified, characterized and optimized. While some factors relate to BVS design and manufacturing, others depend on device deployment and intrinsic vascular properties. Importantly, these factors interact and cannot be considered in isolation. The objective of this study is to quantify the extent to which degree of radial expansion modulates BVS performance, specifically in the context of modifying device erosion kinetics and evolution of structural mechanics and local drug elution. We systematically varied degree of radial expansion in model BVS constructs composed of poly dl-lactide-glycolide and generated in vitro metrics of device microstructure, degradation, erosion, mechanics and drug release. Experimental data permitted development of computational models that predicted transient concentrations of scaffold-derived soluble species and drug in the arterial wall, thus enabling speculation on the short- and long-term effects of differential expansion. We demonstrate that degree of expansion significantly affects scaffold properties critical to functionality, underscoring its relevance in BVS design and optimization. Bioresorbable vascular scaffold (BVS) therapy is beginning to transform the treatment of obstructive artery disease, owing to effective treatment of short term vessel closure while avoiding long term consequences such as in situ, late stent thrombosis - a fatal event associated with permanent implants such as drug-eluting stents. As device scaffolding and drug elution are temporary for BVS, the notion of using this therapy in lieu of existing, clinically approved devices seems attractive. However, there is still a limited understanding regarding the optimal lifetime and performance characteristics of erodible endovascular implants. Several engineering criteria must be met and clinical endpoints confirmed to ensure these devices are both safe and effective. In this manuscript, we sought to establish general principles for the design and deployment of erodible, drug-eluting endovascular scaffolds, with focus on how differential expansion can modulate device performance. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Tsutsumi, Naoto; Hirano, Yoshinori; Kinashi, Kenji; Sakai, Wataru
2018-06-12
The fluorescent properties of dyes and fluorophores in condensed matter significantly affect the laser performance of organic dye lasers and fluorescent polymer lasers. Concentration quenching of fluorescence is commonly observed in condensed matter. Several approaches have been presented to suppress such quenching, such as the use of a dendrimer and the use of effective energy transfer in a guest-host system. The enhanced fluorescence of rhodamine 6G (R6G) dye on a vinylidene fluoride polymer is an alternative method for enhancing laser performance because of the roughness of the P(VDF-TrFE) surface and the interaction between polar β-crystals of P(VDF-TrFE) and R6G dye. In this paper, a significant improvement in slope efficiency (SE) is demonstrated without a significant depression in the lasing threshold for distributed feedback (DFB) and distributed Bragg reflector (DBR) lasers fabricated using an R6G-dispersed cellulose acetate (CA) matrix spin-coated onto a copolymer of vinylidene fluoride and trifluoroethylene P(VDF-TrFE) thin film. SEs of 3.4 and 1.3% were measured for DBR and DFB laser devices with CA/R6G on a P(VDF-TrFE) thin film, respectively, whereas an SE of less than 1.0% was measured for both corresponding laser devices without a P(VDF-TrFE) thin film. From the aspect of simple fabrication procedures, repeatability in device fabrication and performance, stability of the device, time for device fabrication, the present approach is the most preferable way for industrial applications, requiring only the additional step of spin-coating of a P(VDF-TrFE) thin film.
Analysis of DC and analog/RF performance on Cyl-GAA-TFET using distinct device geometry
NASA Astrophysics Data System (ADS)
Vishvakarma, S. K.; Beohar, Ankur; Vijayvargiya, Vikas; Trivedi, Priyal
2017-07-01
In this paper, analysis of DC and analog/RF performance on cylindrical gate-all-around tunnel field-effect transistor (TFET) has been made using distinct device geometry. Firstly, performance parameters of GAA-TFET are analyzed in terms of drain current, gate capacitances, transconductance, source-drain conductance at different radii and channel length. Furthermore, we also produce the geometrical analysis towards the optimized investigation of radio frequency parameters like cut-off frequency, maximum oscillation frequency and gain bandwidth product using a 3D technology computer-aided design ATLAS. Due to band-to-band tunneling based current mechanism unlike MOSFET, gate-bias dependence values as primary parameters of TFET differ. We also analyze that the maximum current occurs when radii of Si is around 8 nm due to high gate controllability over channel with reduced fringing effects and also there is no change in the current of TFET on varying its length from 100 to 40 nm. However current starts to increase when channel length is further reduced for 40 to 30 nm. Both of these trades-offs affect the RF performance of the device. Project supported by the Council of Scientific and Industrial Research (CSIR) Funded Research Project, Grant No. 22/0651/14/EMR-II, Government of India.
NASA Technical Reports Server (NTRS)
Young, L. R.
1975-01-01
Preliminary tests and evaluation are presented of pilot performance during landing (flight paths) using computer generated images (video tapes). Psychophysiological factors affecting pilot visual perception were measured. A turning flight maneuver (pitch and roll) was specifically studied using a training device, and the scaling laws involved were determined. Also presented are medical studies (abstracts) on human response to gravity variations without visual cues, acceleration stimuli effects on the semicircular canals, and neurons affecting eye movements, and vestibular tests.
On the theory of Carriers's Electrostatic Interaction near an Interface
NASA Astrophysics Data System (ADS)
Waters, Michael; Hashemi, Hossein; Kieffer, John
2015-03-01
Heterojunction interfaces are common in non-traditional photovoltaic device designs, such as those based small molecules, polymers, and perovskites. We have examined a number of the effects of the heterojunction interface region on carrier/exciton energetics using a mixture of both semi-classical and quantum electrostatic methods, ab initio methods, and statistical mechanics. Our theoretical analysis has yielded several useful relationships and numerical recipes that should be considered in device design regardless of the particular materials system. As a demonstration, we highlight these formalisms as applied to carriers and polaron pairs near a C60/subphthalocyanine interface. On the regularly ordered areas of the heterojunction, the effect of the interface is a significant set of corrections to the carrier energies, which in turn directly affects device performance.
Comparative study of graphene and its derivative materials as an electrode in OLEDs
NASA Astrophysics Data System (ADS)
Srivastava, Anshika; Kumar, Brijesh
2018-04-01
In current scenario, the organic materials have given a revolutionary evolution in the electronics industry. As, the organic light emitting diodes (OLEDs) have almost replaced the conventional technologies due to the use of organic based materials. However, the next generations OLEDs are intensively desired nowadays for high definition display technology. There are various concern involved in the successful design of OLEDs. Electrodes are one of the electrical conductors, which play a vital role in the construction of OLEDs. The performance of OLED is majorly affected by the material used for electrodes. Due to the requirement of transparent, flexible and inexpensive anodes in bottom emissive OLEDs, ITO was replaced by graphene material. Graphene is a single layer 2-dimensional transparent carbon allotrope which showed prodigious potential to escalate the device performance. Although graphene demonstrated impressive characteristics in various applications, it showed unfavorable work function for many other devices. Thus, derivative materials of graphene such as graphene oxide, graphane and β - graphdiyne were synthesized by several researchers. By comparing graphene and its derivatives as an anode of OLEDs, it has been found that graphene oxide showed the preeminent performance among all. In this paper, all the comparisons are investigated by using a standard device constructed by piling layers of anode/ m_MTDATA/ NPB/ Alq3: QAD/ Alq3/ cathode in TCAD ATLAS device simulator.
Histological evaluation and optimization of surgical vessel sealing systems
NASA Astrophysics Data System (ADS)
Lathrop, Robert; Ryan, Thomas; Gaspredes, Jonathan; Woloszko, Jean; Coad, James E.
2017-02-01
Surgical vessel sealing systems are widely used to achieve hemostasis and dissection in open surgery and minimally invasive, laparoscopic surgery. This enabling technology was developed about 17 years ago and continues to evolve with new devices and systems achieving improved outcomes. Histopathological assessment of thermally sealed tissues is a valuable tool for refining and comparing performance among surgical vessel sealing systems. Early work in this field typically assessed seal time, burst rate, and failure rate (in-situ). Later work compared histological staining methods with birefringence to assess the extent of thermal damage to tissues adjacent to the device. Understanding the microscopic architecture of a sealed vessel is crucial to optimizing the performance of power delivery algorithms and device design parameters. Manufacturers rely on these techniques to develop new products. A system for histopathological evaluation of vessels and sealing performance was established, to enable the direct assessment of a treatment's tissue effects. The parameters included the commonly used seal time, pressure burst rate and failure rate, as well as extensions of the assessment to include its likelihood to form steam vacuoles, adjacent thermal effect near the device, and extent of thermally affected tissue extruded back into the vessel lumen. This comprehensive assessment method provides an improved means of assessing the quality of a sealed vessel and understanding the exact mechanisms which create an optimally sealed vessel.
Energetic mapping of oxide traps in MoS2 field-effect transistors
NASA Astrophysics Data System (ADS)
Illarionov, Yury Yu; Knobloch, Theresia; Waltl, Michael; Rzepa, Gerhard; Pospischil, Andreas; Polyushkin, Dmitry K.; Furchi, Marco M.; Mueller, Thomas; Grasser, Tibor
2017-06-01
The performance of MoS2 transistors is strongly affected by charge trapping in oxide traps with very broad distributions of time constants. These defects degrade the mobility and additionally lead to the hysteresis of the gate transfer characteristics, which presents a crucial performance and reliability issue for these new technologies. Here we perform a detailed study of the hysteresis in double-gated MoS2 FETs and show that this issue is nothing else than a combination of threshold voltage shifts resulting from positive and negative bias-temperature instabilities. While these instabilities are well known from silicon devices, they are even more important in 2D devices given the considerably larger defect densities. Most importantly, the magnitudes of these threshold voltage shifts depend strongly on the density and energetic alignment of the active oxide traps. Based on this, we introduce the incremental hysteresis sweep method which allows for an accurate mapping of these defects and extract their energy distributions from simulations. By applying our method to analyze the impact of oxide traps situated in the Al2O3 top gate of several devices, we confirm its versatility. Since all 2D devices investigated so far suffer from a similar hysteresis behavior, the incremental hysteresis sweep method provides a unique and powerful way for the detailed characterization of their defect bands.
Correlating Microstructure and Optoelectronic Performance of Carbon-Based Nanomaterials
NASA Astrophysics Data System (ADS)
Rochford, Caitlin
There is a great deal of interest in carbon nanostructures such as graphene and various forms of carbon nanotubes due to their exceptional physical, electronic, and optical properties. Many technological applications have been proposed for these nanostructures, but despite the promise many carbon nanostructure-based optoelectronic devices fail to compete with their conventional counterparts. This is often due in large part to a non-optimized material or device microstructure. Factors such as crystallinity, contact quality, defect structure, and device configuration can critically affect device performance due to the high sensitivity and extreme surface to volume ratio of carbon nanostructures. In order for the exceptional intrinsic properties of the nanostructures to be exploited, a clear understanding of the microstructure and its correlation with device-relevant optoelectronic properties is needed. This dissertation presents four projects which demonstrate this principle. First, a TiO 2-coated carbon nanofiber is studied in order to optimize its structure for use in a novel dye-sensitized solar cell. Second, the electrode configuration of an individual multiwall carbon nanotube infrared sensor is investigated in order to surpass the limitations of disordered nanotube film-based infrared sensors. Third, the properties of defect structures in large area transferred graphene films grown by chemical vapor deposition are correlated with carrier diffusion in order to understand the film's low mobility compared to exfoliated graphene. Fourth, the effect of deposition conditions on graphene-metal contact was studied with the goal of achieving sufficiently transparent contacts for investigation of the superconducting proximity effect. All four projects highlight the unique properties of carbon nanostructures as well as the need to correlate their optoelectronic properties with microstructural details in order to achieve the desired device performance.
Wells, Sue; Rafter, Natasha; Kenealy, Timothy; Herd, Geoff; Eggleton, Kyle; Lightfoot, Rose; Arcus, Kim; Wadham, Angela; Jiang, Yannan; Bullen, Chris
2017-01-01
To assess the effect of a point of care (POC) device for testing lipids and HbA1c in addition to testing by community laboratory facilities (usual practice) on the completion of cardiovascular disease (CVD) risk assessments in general practice. We conducted a pragmatic, cluster randomised controlled trial in 20 New Zealand general practices stratified by size and rurality and randomised to POC device plus usual practice or usual practice alone (controls). Patients aged 35-79 years were eligible if they met national guideline criteria for CVD risk assessment. Data on CVD risk assessments were aggregated using a web-based decision support programme common to each practice. Data entered into the on-line CVD risk assessment form could be saved pending blood test results. The primary outcome was the proportion of completed CVD risk assessments. Qualitative data on practice processes for CVD risk assessment and feasibility of POC testing were collected at the end of the study by interviews and questionnaire. The POC testing was supported by a comprehensive quality assurance programme. A CVD risk assessment entry was recorded for 7421 patients in 10 POC practices and 6217 patients in 10 control practices; 99.5% of CVD risk assessments had complete data in both groups (adjusted odds ratio 1.02 [95%CI 0.61-1.69]). There were major external influences that affected the trial: including a national performance target for CVD risk assessment and changes to CVD guidelines. All practices had invested in systems and dedicated staff time to identify and follow up patients to completion. However, the POC device was viewed by most as an additional tool rather than as an opportunity to review practice work flow and leverage the immediate test results for patient education and CVD risk management discussions. Shortly after commencement, the trial was halted due to a change in the HbA1c test assay performance. The trial restarted after the manufacturing issue was rectified but this affected the end use of the device. Performance incentives and external influences were more powerful modifiers of practice behaviours than the POC device in relation to CVD risk assessment completion. The promise of combining risk assessment, communication and management within one consultation was not realised. With shifts in policy focus, the utility of POC devices for patient engagement in CVD preventive care may be demonstrated if fully integrated into the clinical setting. Australian New Zealand Clinical Trials Registry ACTRN12613000607774.
Mercury in coal and the impact of coal quality on mercury emissions from combustion systems
Kolker, A.; Senior, C.L.; Quick, J.C.
2006-01-01
The proportion of Hg in coal feedstock that is emitted by stack gases of utility power stations is a complex function of coal chemistry and properties, combustion conditions, and the positioning and type of air pollution control devices employed. Mercury in bituminous coal is found primarily within Fe-sulfides, whereas lower rank coal tends to have a greater proportion of organic-bound Hg. Preparation of bituminous coal to reduce S generally reduces input Hg relative to in-ground concentrations, but the amount of this reduction varies according to the fraction of Hg in sulfides and the efficiency of sulfide removal. The mode of occurrence of Hg in coal does not directly affect the speciation of Hg in the combustion flue gas. However, other constituents in the coal, notably Cl and S, and the combustion characteristics of the coal, influence the species of Hg that are formed in the flue gas and enter air pollution control devices. The formation of gaseous oxidized Hg or particulate-bound Hg occurs post-combustion; these forms of Hg can be in part captured in the air pollution control devices that exist on coal-fired boilers, without modification. For a given coal type, the capture efficiency of Hg by pollution control systems varies according to type of device and the conditions of its deployment. For bituminous coal, on average, more than 60% of Hg in flue gas is captured by fabric filter (FF) and flue-gas desulfurization (FGD) systems. Key variables affecting performance for Hg control include Cl and S content of the coal, the positioning (hot side vs. cold side) of the system, and the amount of unburned C in coal ash. Knowledge of coal quality parameters and their effect on the performance of air pollution control devices allows optimization of Hg capture co-benefit. ?? 2006 Elsevier Ltd. All rights reserved.
TiO2 Nanotubes: Recent Advances in Synthesis and Gas Sensing Properties
Galstyan, Vardan; Comini, Elisabetta; Faglia, Guido; Sberveglieri, Giorgio
2013-01-01
Synthesis—particularly by electrochemical anodization-, growth mechanism and chemical sensing properties of pure, doped and mixed titania tubular arrays are reviewed. The first part deals on how anodization parameters affect the size, shape and morphology of titania nanotubes. In the second part fabrication of sensing devices based on titania nanotubes is presented, together with their most notable gas sensing performances. Doping largely improves conductivity and enhances gas sensing performances of TiO2 nanotubes. PMID:24184919
NASA Technical Reports Server (NTRS)
Harper, Richard E.; Butler, Bryan P.
1990-01-01
The Draper fault-tolerant processor with fault-tolerant shared memory (FTP/FTSM), which is designed to allow application tasks to continue execution during the memory alignment process, is described. Processor performance is not affected by memory alignment. In addition, the FTP/FTSM incorporates a hardware scrubber device to perform the memory alignment quickly during unused memory access cycles. The FTP/FTSM architecture is described, followed by an estimate of the time required for channel reintegration.
Evolution and update on current devices for prosthetic breast reconstruction
2015-01-01
Over the past decade, the leading breast reconstruction modality has shifted from autologous tissue to implants. This trend reversal is multi-factorial but includes increasing bilateral mastectomies and the more widespread acceptance of implants due to stringent quality and safety regulatory surveillance by the US Food and Drug Administration (FDA). Since 2012, the US FDA has approved several new implant styles, shapes and textures, increasing the choices for patients and surgeons. Predictable, superior aesthetic results after prosthetic breast reconstruction are attainable, but require thoughtful planning, precise surgical technique and appropriate device selection based on several different patient and surgeon parameters, such as patient desires, body mass index, breast shape, mastectomy flap quality and tissue based bio-dimensional assessment. This article briefly reviews historic devices used in prosthetic breast reconstruction beginning in the 1960s through the modern generation devices used today. We reflect on the rigorous hurdles endured over the last several decades leading to the approval of silicone gel devices, along with their well-established safety and efficacy. The various implant characteristics can affect feel and performance of the device. The many different styles and features of implants and expanders are described emphasizing surgical indications, advantages and disadvantages of each device. PMID:26005642
Performance predictors of brain-computer interfaces in patients with amyotrophic lateral sclerosis
NASA Astrophysics Data System (ADS)
Geronimo, A.; Simmons, Z.; Schiff, S. J.
2016-04-01
Objective. Patients with amyotrophic lateral sclerosis (ALS) may benefit from brain-computer interfaces (BCI), but the utility of such devices likely will have to account for the functional, cognitive, and behavioral heterogeneity of this neurodegenerative disorder. Approach. In this study, a heterogeneous group of patients with ALS participated in a study on BCI based on the P300 event related potential and motor-imagery. Results. The presence of cognitive impairment in these patients significantly reduced the quality of the control signals required to use these communication systems, subsequently impairing performance, regardless of progression of physical symptoms. Loss in performance among the cognitively impaired was accompanied by a decrease in the signal-to-noise ratio of task-relevant EEG band power. There was also evidence that behavioral dysfunction negatively affects P300 speller performance. Finally, older participants achieved better performance on the P300 system than the motor-imagery system, indicating a preference of BCI paradigm with age. Significance. These findings highlight the importance of considering the heterogeneity of disease when designing BCI augmentative and alternative communication devices for clinical applications.
Tom, James
2016-01-01
The prevalence of cardiovascular implantable electronic devices as life-prolonging and life-saving devices has evolved from a treatment of last resort to a first-line therapy for an increasing number of patients. As these devices become more and more popular in the general population, dental providers utilizing instruments and medications should be aware of dental equipment and medications that may affect these devices and understand the management of patients with these devices. This review article will discuss the various types and indications for pacemakers and implantable cardioverter-defibrillators, common drugs and instruments affecting these devices, and management of patients with these devices implanted for cardiac dysrhythmias.
Tom, James
2016-01-01
The prevalence of cardiovascular implantable electronic devices as life-prolonging and life-saving devices has evolved from a treatment of last resort to a first-line therapy for an increasing number of patients. As these devices become more and more popular in the general population, dental providers utilizing instruments and medications should be aware of dental equipment and medications that may affect these devices and understand the management of patients with these devices. This review article will discuss the various types and indications for pacemakers and implantable cardioverter-defibrillators, common drugs and instruments affecting these devices, and management of patients with these devices implanted for cardiac dysrhythmias. PMID:27269668
Feasibility and Limitations of Vaccine Two-Dimensional Barcoding Using Mobile Devices.
Bell, Cameron; Guerinet, Julien; Atkinson, Katherine M; Wilson, Kumanan
2016-06-23
Two-dimensional (2D) barcoding has the potential to enhance documentation of vaccine encounters at the point of care. However, this is currently limited to environments equipped with dedicated barcode scanners and compatible record systems. Mobile devices may present a cost-effective alternative to leverage 2D vaccine vial barcodes and improve vaccine product-specific information residing in digital health records. Mobile devices have the potential to capture product-specific information from 2D vaccine vial barcodes. We sought to examine the feasibility, performance, and potential limitations of scanning 2D barcodes on vaccine vials using 4 different mobile phones. A unique barcode scanning app was developed for Android and iOS operating systems. The impact of 4 variables on the scan success rate, data accuracy, and time to scan were examined: barcode size, curvature, fading, and ambient lighting conditions. Two experimenters performed 4 trials 10 times each, amounting to a total of 2160 barcode scan attempts. Of the 1832 successful scans performed in this evaluation, zero produced incorrect data. Five-millimeter barcodes were the slowest to scan, although only by 0.5 seconds on average. Barcodes with up to 50% fading had a 100% success rate, but success rate deteriorated beyond 60% fading. Curved barcodes took longer to scan compared with flat, but success rate deterioration was only observed at a vial diameter of 10 mm. Light conditions did not affect success rate or scan time between 500 lux and 20 lux. Conditions below 20 lux impeded the device's ability to scan successfully. Variability in scan time was observed across devices in all trials performed. 2D vaccine barcoding is possible using mobile devices and is successful under the majority of conditions examined. Manufacturers utilizing 2D barcodes should take into consideration the impact of factors that limit scan success rates. Future studies should evaluate the effect of mobile barcoding on workflow and vaccine administrator acceptance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lawson, M.; Yu, Y. H.; Nelessen, A.
2014-05-01
Wave energy converters (WECs) are commonly designed and analyzed using numerical models that combine multi-body dynamics with hydrodynamic models based on the Cummins Equation and linearized hydrodynamic coefficients. These modeling methods are attractive design tools because they are computationally inexpensive and do not require the use of high performance computing resources necessitated by high-fidelity methods, such as Navier Stokes computational fluid dynamics. Modeling hydrodynamics using linear coefficients assumes that the device undergoes small motions and that the wetted surface area of the devices is approximately constant. WEC devices, however, are typically designed to undergo large motions in order to maximizemore » power extraction, calling into question the validity of assuming that linear hydrodynamic models accurately capture the relevant fluid-structure interactions. In this paper, we study how calculating buoyancy and Froude-Krylov forces from the instantaneous position of a WEC device (referred to as instantaneous buoyancy and Froude-Krylov forces from herein) changes WEC simulation results compared to simulations that use linear hydrodynamic coefficients. First, we describe the WEC-Sim tool used to perform simulations and how the ability to model instantaneous forces was incorporated into WEC-Sim. We then use a simplified one-body WEC device to validate the model and to demonstrate how accounting for these instantaneously calculated forces affects the accuracy of simulation results, such as device motions, hydrodynamic forces, and power generation.« less
A Self-Validation Method for High-Temperature Thermocouples Under Oxidizing Atmospheres
NASA Astrophysics Data System (ADS)
Mokdad, S.; Failleau, G.; Deuzé, T.; Briaudeau, S.; Kozlova, O.; Sadli, M.
2015-08-01
Thermocouples are prone to significant drift in use particularly when they are exposed to high temperatures. Indeed, high-temperature exposure can affect the response of a thermocouple progressively by changing the structure of the thermoelements and inducing inhomogeneities. Moreover, an oxidizing atmosphere contributes to thermocouple drift by changing the chemical nature of the metallic wires by the effect of oxidation. In general, severe uncontrolled drift of thermocouples results from these combined influences. A periodic recalibration of the thermocouple can be performed, but sometimes it is not possible to remove the sensor out of the process. Self-validation methods for thermocouples provide a solution to avoid this drawback, but there are currently no high-temperature contact thermometers with self-validation capability at temperatures up to . LNE-Cnam has developed fixed-point devices integrated to the thermocouples consisting of machined alumina-based devices for operation under oxidizing atmospheres. These devices require small amounts of pure metals (typically less than 2 g). They are suitable for self-validation of high-temperature thermocouples up to . In this paper the construction and the characterization of these integrated fixed-point devices are described. The phase-transition plateaus of gold, nickel, and palladium, which enable coverage of the temperature range between and , are assessed with this self-validation technique. Results of measurements performed at LNE-Cnam with the integrated self-validation module at several levels of temperature will be presented. The performance of the devices are assessed and discussed, in terms of robustness and metrological characteristics. Uncertainty budgets are also proposed and detailed.
Thermally responsive polymer electrolytes for inherently safe electrochemical energy storage
NASA Astrophysics Data System (ADS)
Kelly, Jesse C.
Electrochemical double layer capacitors (EDLCs), supercapacitors and Li-ion batteries have emerged as premier candidates to meet the rising demands in energy storage; however, such systems are limited by thermal hazards, thermal runaway, fires and explosions, all of which become increasingly more dangerous in large-format devices. To prevent such scenarios, thermally-responsive polymer electrolytes (RPEs) that alter properties in electrochemical energy storage devices were designed and tested. These RPEs will be used to limit or halt device operation when temperatures increase beyond a predetermined threshold, therefore limiting further heating. The development of these responsive systems will offer an inherent safety mechanism in electrochemical energy storage devices, while preserving the performance, lifetimes, and versatility that large-format systems require. Initial work focused on the development of a model system that demonstrated the concept of RPEs in an electrochemical device. Aqueous electrolyte solutions of polymers exhibiting properties that change in response to temperature were developed for applications in EDLCs and supercapacitors. These "smart materials" provide a means to control electrochemical systems where polymer phase separation at high temperatures affects electrolyte properties and inhibits device performance. Aqueous RPEs were synthesized using N-isopropylacrylamide, which governs the thermal properties, and fractions of acrylic acid or vinyl sulfonic acids, which provide ions to the solution. The molecular properties of these aqueous RPEs, specifically the ionic composition, were shown to influence the temperature-dependent electrolyte properties and the extent to which these electrolytes control the energy storage characteristics of a supercapacitor device. Materials with high ionic content provided the highest room temperature conductivity and electrochemical activity; however, RPEs with low ionic content provided the highest "on-off" ratio in electrochemical activity at elevated temperatures. Overall, solution pH and conductivity were altered by an order of magnitude and device performance (ability to store charge) decreased by over 70%. After demonstration of a model responsive electrolyte in an aqueous system, ionic liquid (IL) based electrolytes were developed as a means of controlling the electrochemical performance in the non-aqueous environments that batteries, specifically Li-ion, require. Here, two systems were developed: (1) an electrolyte comprising poly(ethylene oxide) (PEO), the IL, [EMIM][BF4], and a lithium salt and (2) an electrolyte comprising poly(benzyl methacrylate) (PBzMA), the IL, [EMIM][TFSI], and a lithium salt. In each system, the polymer-IL phase separation inhibited device operation at elevated temperatures. For the PEO/IL electrolyte, the thermally induced liquid-liquid phase separation was shown to decrease the ionic conductivity, thereby affecting the concentration of ions at the electrode. Additionally, an increasing charge transfer resistance associated with the phase separated polymer coating the porous electrode was shown to limit electrochemical activity significantly. For the PBzMA/IL electrolyte, the solid-liquid phase separation did not show a change in conductivity, but did cause a drastic increase in charge transfer resistance, effectively shutting off Li-ion battery operation at high temperatures. Such responsive mixtures provide a transformative approach to regulating electrochemical processes, which is necessary to achieve inherently safe operation in large format energy storage with EDLCs, supercapacitors and Li-ion batteries.
1993-08-15
interferometric modulators has been shown [1 ],[2] to be affected by device annealing, with increased sensitivity demonstrated at annealing temperatures...changes in modulator performance. The measurements reported here were all made on Mach-Zehnder interferometric modula- tors fabricated on X-cut, Y...cooled under an arsine flow to the growth temperature used for InAs. The surface morphology of the InAs layers was examined by Nomarski contrast
40 CFR Table 2 to Subpart Ooo - Stack Emission Limits for Affected Facilities With Capture Systems
Code of Federal Regulations, 2010 CFR
2010-07-01
... 60.671) that commenced construction, modification, or reconstruction after August 31, 1983 but before April 22, 2008 0.05 g/dscm (0.022 gr/dscf) a 7 percent for dry control devices b An initial performance....670 and 60.671) that commence construction, modification, or reconstruction on or after April 22, 2008...
Does Sleeve Shape Make a Difference in Outcomes?
Alhaj Saleh, Adel; Janik, Michal R; Mustafa, Rami R; Alshehri, Mohammed; Khan, Adil H; Kalantar Motamedi, Seyed Mohammad; Rahim, Shiraz; Patel, Indravadan; Aryaie, Amir; Abbas, Mujjahid; Rogula, Tomasz; Khaitan, Leena
2018-06-01
Sleeve gastrectomy (SG) is one of the most common procedures performed for weight loss. Many seek the "perfect sleeve" with the notion that the type of calibrating device affects sleeve shape, and this in turn will affect outcomes and complications. Two major concerns after SG are amount of weight loss and acid reflux. Our aim was to determine if the various calibration methods could impact sleeve shape and thereby allow for better outcomes of weight loss and reflux. A retrospective chart review was performed of 210 patients who underwent SG and had postoperative upper gastrointestinal (UGI) study from 2011 to 2015 in a single center by a single (fellowship-trained) bariatric surgeon. Data regarding demographics, calibrating devices and clinical outcomes at 1 year (weight loss and de novo acid reflux) were collected. UGIs were reviewed by two radiologists blinded to the clinical outcomes. Sleeve shape was classified according to a previously described classification as tubular, dumbbell, upper pouch, or lower pouch. The types of calibrating devices used to guide the sleeve size intraoperatively were endoscopy, large-bore orogastric tube, and fenestrated suction tube. One hundred ninety-nine patients met inclusion criteria (11 had no esophagram). Demographics revealed age 45.76 ± 10.6 years, BMI 47 ± 8.6 kg/m 2 , and 82% female. Calibration devices used were endoscopic guidance (7.6%), large bore orogastric tube (41.4%), and fenestrated suction tube (50.5%). Sleeve shape was reported as 32.6% tubular, 20.6% dumbbell, 39.2% lower pouch, and 7.5% upper pouch (100% interrater reliability). No correlation was seen with type of calibration used. Of patients, 62.0% had > 50% excess weight loss at 1 year. Twenty-three percent of patients remained on PPI at 1 year (of which 43.3% did not have reflux preoperatively). The lower pouch shape showed a trend toward less reflux and more weight loss. This study showed no clear association between uniformity of sleeve shape and the type of calibration device used. The study showed a trend toward decreased reflux and improved weight loss with the lower pouch shape, regardless of calibration device.
NASA Astrophysics Data System (ADS)
Smith, Kathryn Leigh
This dissertation presents research results demonstrating the efficacy of fractal-inspired subwavelength geometric inclusions for improvement of high-frequency electromagnetic devices. It begins with a review of the open literature in the area of fractal applications in antennas and metamaterials. This is followed by a detailed discussion of three high-frequency electromagnetic devices that demonstrate performance improvement through incorporation of subwavelength geometric design elements. The first of these devices is a spherical spiral metamaterial unit cell that was developed as a three-dimensional fractal expansion of the traditional split ring resonator, and is shown to be capable of producing broadband negative permeability, negative permittivity, or both, depending solely on the orientation of the unit cells with respect to the incident electric field. The second device is a ringed rectangular patch antenna that has four resonant frequencies. All four of these operative frequencies are shown to produce similar radiation patterns, which also closely match the pattern of a traditional patch antenna. Several minor geometric modifications of the basic shape of the device are also presented, and are shown to enable modification of the number of resonances, as well as tuning of frequencies of resonance. The third and final topic is a modified horn antenna that incorporates a spiral metamaterial as a phase-shifting device in order to achieve circularly polarized radiation. The handedness of the radiated wave is shown to be tunable through simple reorientation of the loading unit cells. In each of these cases, electrically-small geometric modification of existing device geometries is shown to greatly affect performance, either by increasing bandwidth, by inducing multiband behavior, or by enabling exotic radiation characteristics.
Gonzalez-Suarez, Alan Mauricio; Peña-Del Castillo, Johanna G; Hernandez-Cruz, Arturo; Garcia-Cordero, Jose Luis
2018-06-19
Intracellular signaling pathways are affected by the temporal nature of external chemical signaling molecules such as neuro-transmitters or hormones. Developing high-throughput technologies to mimic these time-varying chemical signals and to analyze the response of single cells would deepen our understanding of signaling networks. In this work, we introduce a microfluidic platform to stimulate hundreds of single cells with chemical waveforms of tunable frequency and amplitude. Our device produces a linear gradient of 9 concentrations that are delivered to an equal number of chambers, each containing 492 microwells, where individual cells are captured. The device can alternate between the different stimuli concentrations and a control buffer, with a maximum operating frequency of 33 mHz that can be adjusted from a computer. Fluorescent time-lapse microscopy enables to obtain hundreds of thousands of data points from one experiment. We characterized the gradient performance and stability by staining hundreds of cells with calcein AM. We also assessed the capacity of our device to introduce periodic chemical stimuli of different amplitudes and frequencies. To demonstrate our device performance, we studied the dynamics of intracellular Ca2+ release from intracellular stores of HEK cells when stimulated with carbachol at 4.5 and 20 mHz. Our work opens the possibility of characterizing the dynamic responses in real time of signaling molecules to time-varying chemical stimuli with single cell resolution.
Reducing the net torque and flow ripple effects of multiple hydraulic piston motor drives
NASA Technical Reports Server (NTRS)
Bartos, R. D.
1992-01-01
The torque and flow ripple effects which result when multiple hydraulic motors are used to drive a single motion of a mechanical device can significantly affect the way in which the device performs. This article presents a mathematical model describing the torque and flow ripple effects of a bent-axis hydraulic piston motor. The model is used to show how the ripple magnitude can be reduced when multiple motors are used to drive a motion. A discussion of the hydraulic servo system of the 70-m antennas located with the Deep Space Network is included to demonstrate the application of the concepts presented.
Colorimetry Technique for Scalable Characterization of Suspended Graphene.
Cartamil-Bueno, Santiago J; Steeneken, Peter G; Centeno, Alba; Zurutuza, Amaia; van der Zant, Herre S J; Houri, Samer
2016-11-09
Previous statistical studies on the mechanical properties of chemical-vapor-deposited (CVD) suspended graphene membranes have been performed by means of measuring individual devices or with techniques that affect the material. Here, we present a colorimetry technique as a parallel, noninvasive, and affordable way of characterizing suspended graphene devices. We exploit Newton's rings interference patterns to study the deformation of a double-layer graphene drum 13.2 μm in diameter when a pressure step is applied. By studying the time evolution of the deformation, we find that filling the drum cavity with air is 2-5 times slower than when it is purged.
Cavitation in centrifugal pump with rotating walls of axial inlet device
NASA Astrophysics Data System (ADS)
Moloshnyi, O.; Sotnyk, M.
2017-08-01
The article deals with the analysis of cavitation processes in the flowing part of the double entry centrifugal pump. The analysis is conducted using numerical modeling of the centrifugal pump operating process in the software environment ANSYS CFX. Two models of the axial inlet device is researched. It is shaped by a cylindrical section and diffuser section in front of the impeller, which includes fairing. The walls of the axial inlet device rotate with the same speed as the pump rotor. The numerical experiment is conducted under the condition of the flow rate change and absolute pressure at the inlet. The analysis shows that the pump has the average statistical cavitation performance. The occurrence of the cavitation in the axial inlet device is after narrowing the cross-section of flow channel and at the beginning of the diffuser section. Additional sudden expansion at the outlet of the axial inlet diffuser section does not affect the cavitation characteristics of the impeller, however, improves cavitation characteristics of the axial inlet device. For considered geometric parameters of the axial inlet device the cavitation in the impeller begins earlier than in the axial inlet device. That is, the considered design of the axial inlet device will not be subjected to destruction at the ensuring operation without cavitation in the impeller.
Elongational Flow Assists with the Assembly of Protein Nanofibrils
NASA Astrophysics Data System (ADS)
Mittal, Nitesh; Kamada, Ayaka; Lendel, Christofer; Lundell, Fredrik; Soderberg, Daniel
2016-11-01
Controlling the aggregation process of protein-based macromolecular structures in a confined environment using small-scale flow devices and understanding their assembly mechanisms is essential to develop bio-based materials. Whey protein, a protein mixture with β-lactoglobulin as main component, is able to self-assemble into amyloid-like protein nanofibers which are stabilized by hydrogen bonds. The conditions at which the fibrillation process occurs can affect the properties and morphology of the fibrils. Here, we show that the morphology of protein nanofibers greatly affects their assembly. We used elongational flow based double flow-focusing device for this study. In-situ behavior of the straight and flexible fibrils in the flow channel is determined using small-angle X-ray scattering (SAXS) technique. Our process combines hydrodynamic alignment with dispersion to gel-transition that produces homogeneous and smooth fibers. Moreover, successful alignment before gelation demands a proper separation of the time-scales involved, which we tried to identify in the current study. The presented approach combining small scale flow devices with in-situ synchrotron X-ray studies and protein engineering is a promising route to design high performance protein-based materials with controlled physical and chemical properties. We acknowledge the support from Wallenberg Wood Science Center.
Aroul, A L Praveen; Bhatia, Dinesh
2011-01-01
Continued miniaturization of electronic devices and technological advancements in wireless communications has made wearable body-centric telemedicine systems viable. Antennas play a crucial role in characterizing the efficiency and reliability of these systems. The performance characteristics such as the radiation pattern, gain, efficiency of the antennas get adversely affected due to the presence of lossy human body tissues. In this paper we investigate the above mentioned performance parameters and radio frequency transmission properties of wire and planar structures operating at ISM frequency band of 2.40-2.50 GHz in the proximity of human body.
Using Mason number to predict MR damper performance from limited test data
NASA Astrophysics Data System (ADS)
Becnel, Andrew C.; Wereley, Norman M.
2017-05-01
The Mason number can be used to produce a single master curve which relates MR fluid stress versus strain rate behavior across a wide range of shear rates, temperatures, and applied magnetic fields. As applications of MR fluid energy absorbers expand to a variety of industries and operating environments, Mason number analysis offers a path to designing devices with desired performance from a minimal set of preliminary test data. Temperature strongly affects the off-state viscosity of the fluid, as the passive viscous force drops considerably at higher temperatures. Yield stress is not similarly affected, and stays relatively constant with changing temperature. In this study, a small model-scale MR fluid rotary energy absorber is used to measure the temperature correction factor of a commercially-available MR fluid from LORD Corporation. This temperature correction factor is identified from shear stress vs. shear rate data collected at four different temperatures. Measurements of the MR fluid yield stress are also obtained and related to a standard empirical formula. From these two MR fluid properties - temperature-dependent viscosity and yield stress - the temperature-corrected Mason number is shown to predict the force vs. velocity performance of a full-scale rotary MR fluid energy absorber. This analysis technique expands the design space of MR devices to high shear rates and allows for comprehensive predictions of overall performance across a wide range of operating conditions from knowledge only of the yield stress vs. applied magnetic field and a temperature-dependent viscosity correction factor.
Wang, Jing; Qi, Minghao; Xuan, Yi; Huang, Haiyang; Li, You; Li, Ming; Chen, Xin; Jia, Qi; Sheng, Zhen; Wu, Aimin; Li, Wei; Wang, Xi; Zou, Shichang; Gan, Fuwan
2014-01-01
A novel silicon-on-insulator (SOI) polarization splitter-rotator (PSR) with a large fabrication tolerance is proposed based on cascaded multimode interference (MMI) couplers and an assisted mode-evolution taper. The tapers are designed to adiabatically convert the input TM0 mode into the TE1 mode, which will output as the TE0 mode after processed by the subsequent MMI mode converter, 90-degree phase shifter (PS) and MMI 3 dB coupler. The numerical simulation results show that the proposed device has a < 0.5 dB insertion loss with < −17 dB crosstalk in C optical communication band. Fabrication tolerance analysis is also performed with respect to the deviations of MMI coupler width, PS width, slab height and upper-cladding refractive index, showing that this device could work well even when affected by considerable fabrication errors. With such a robust performance with a large bandwidth, this device offers potential applications for CMOS-compatible polarization diversity, especially in the booming 100 Gb/s coherent optical communications based on silicon photonics technology. PMID:25402029
Wang, Jing; Qi, Minghao; Xuan, Yi; Huang, Haiyang; Li, You; Li, Ming; Chen, Xin; Jia, Qi; Sheng, Zhen; Wu, Aimin; Li, Wei; Wang, Xi; Zou, Shichang; Gan, Fuwan
2014-11-17
A novel silicon-on-insulator (SOI) polarization splitter-rotator (PSR) with a large fabrication tolerance is proposed based on cascaded multimode interference (MMI) couplers and an assisted mode-evolution taper. The tapers are designed to adiabatically convert the input TM(0) mode into the TE(1) mode, which will output as the TE(0) mode after processed by the subsequent MMI mode converter, 90-degree phase shifter (PS) and MMI 3 dB coupler. The numerical simulation results show that the proposed device has a < 0.5 dB insertion loss with < -17 dB crosstalk in C optical communication band. Fabrication tolerance analysis is also performed with respect to the deviations of MMI coupler width, PS width, slab height and upper-cladding refractive index, showing that this device could work well even when affected by considerable fabrication errors. With such a robust performance with a large bandwidth, this device offers potential applications for CMOS-compatible polarization diversity, especially in the booming 100 Gb/s coherent optical communications based on silicon photonics technology.
INK-JET PRINTING OF PF6 FOR OLED APPLICATIONS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burrasca, G.; Fasolino, T.; Miscioscia, R.
2008-08-28
In the last years there has been much interest in applying ink-jet printing (IJP) technology to the deposition of several materials for organic electronics applications, including metals, polymers and nanoparticles dispersions on flexible substrates. The aim of this work is to study the effect of ink-jet deposition of polymer films in the manufacturing of OLED devices comparing their performances to standard technologies. The ink-jet printed polymer is introduced in an hybrid structure in which other layers are deposited by vacuum thermal evaporation. The electrical and optical properties of the obtained devices are investigated.OLEDs with the same structure were fabricated bymore » spin-coating a polymer film by the same solution used as ink. Results have been compared to the above ones to determine how the deposition method affects the device optoelectronic properties.« less
Combinatorial study of zinc tin oxide thin-film transistors
NASA Astrophysics Data System (ADS)
McDowell, M. G.; Sanderson, R. J.; Hill, I. G.
2008-01-01
Groups of thin-film transistors using a zinc tin oxide semiconductor layer have been fabricated via a combinatorial rf sputtering technique. The ZnO :SnO2 ratio of the film varies as a function of position on the sample, from pure ZnO to SnO2, allowing for a study of zinc tin oxide transistor performance as a function of channel stoichiometry. The devices were found to have mobilities ranging from 2to12cm2/Vs, with two peaks in mobility in devices at ZnO fractions of 0.80±0.03 and 0.25±0.05, and on/off ratios as high as 107. Transistors composed predominantly of SnO2 were found to exhibit light sensitivity which affected both the on/off ratios and threshold voltages of these devices.
TEM-nanoindentation studies of semiconducting structures.
Le Bourhis, E; Patriarche, G
2007-01-01
This paper reviews the application of nanoindentation coupled with transmission electron microscopy (TEM) to investigations of the plastic behaviour of semiconducting structures and its implication for device design. Instrumented nanoindentation has been developed to extract the mechanical behaviour of small volumes scaled to those encountered in semiconductor heterostructures. We illustrate that TEM is a powerful complementary tool for the study of local plasticity induced by nanoindentation. TEM-nanoindentation allows for detailed understanding of the plastic deformation in semiconducting structures and opens practical routes for improvement of devices. Performances of heterostructures are deteriously affected by dislocations that relax the lattice mismatched layers. Different ways to obtain compliant substructures are being developed in order to concentrate the plastic relaxation underneath the heterostructure. Such approaches allow for mechanical design of micro- and opto-electronic devices to be considered throughout the fabrication process.
Studies on fully transparent Al-Sn-Zn-O thin-film transistors fabricated on glass at low temperature
NASA Astrophysics Data System (ADS)
Cong, Yingying; Han, Dedong; Wu, Jing; Zhao, Nannan; Chen, Zhuofa; Zhao, Feilong; Dong, Junchen; Zhang, Shengdong; Zhang, Xing; Wang, Yi
2015-04-01
High-performance fully transparent Al-Sn-Zn-O thin-film transistors (ATZO TFTs) with excellent electrical performance have been successfully fabricated by RF magnetron sputtering on glass at low temperatures. Two kinds of appropriate ATZO compositions are compared from several perspectives, including film material characteristics, device electrical performances, and fabrication process conditions. Finally, we achieve two excellent ATZO TFTs with competitive advantages. The ATZO TFT with larger amounts of dopants exhibits a superior field effect mobility μFE of 102.38 cm2 V-1 s-1, an ON/OFF current ratio (Ion/Ioff) of 1.18 × 107, and a threshold voltage VT of 1.35 V. The device with smaller amounts of dopants demonstrates better crystal quality and an excellent subthreshold swing SS of 155 mV/dec. Furthermore, it is less affected by oxygen partial pressure. The ATZO thin films display a high transmittance of over 80% in the visible light range.
Dependence of Grain Size on the Performance of a Polysilicon Channel TFT for 3D NAND Flash Memory.
Kim, Seung-Yoon; Park, Jong Kyung; Hwang, Wan Sik; Lee, Seung-Jun; Lee, Ki-Hong; Pyi, Seung Ho; Cho, Byung Jin
2016-05-01
We investigated the dependence of grain size on the performance of a polycrystalline silicon (poly-Si) channel TFT for application to 3D NAND Flash memory devices. It has been found that the device performance and memory characteristics are strongly affected by the grain size of the poly-Si channel. Higher on-state current, faster program speed, and poor endurance/reliability properties are observed when the poly-Si grain size is large. These are mainly attributed to the different local electric field induced by an oxide valley at the interface between the poly-Si channel and the gate oxide. In addition, the trap density at the gate oxide interface was successfully measured using a charge pumping method by the separation between the gate oxide interface traps and traps at the grain boundaries in the poly-Si channel. The poly-Si channel with larger grain size has lower interface trap density.
2012-01-01
The performance of a semiconducting carbon nanotube (CNT) is assessed and tabulated for parameters against those of a metal-oxide-semiconductor field-effect transistor (MOSFET). Both CNT and MOSFET models considered agree well with the trends in the available experimental data. The results obtained show that nanotubes can significantly reduce the drain-induced barrier lowering effect and subthreshold swing in silicon channel replacement while sustaining smaller channel area at higher current density. Performance metrics of both devices such as current drive strength, current on-off ratio (Ion/Ioff), energy-delay product, and power-delay product for logic gates, namely NAND and NOR, are presented. Design rules used for carbon nanotube field-effect transistors (CNTFETs) are compatible with the 45-nm MOSFET technology. The parasitics associated with interconnects are also incorporated in the model. Interconnects can affect the propagation delay in a CNTFET. Smaller length interconnects result in higher cutoff frequency. PMID:22901374
Game-based, portable, upper extremity rehabilitation in chronic stroke.
Schuck, Sarah O; Whetstone, Amy; Hill, Valerie; Levine, Peter; Page, Stephen J
2011-01-01
This case series pilot study evaluates the efficacy of the Core:Tx gaming device on 2 chronic stroke survivors. Intervention was provided 3 times a week for 3 weeks. Outcome measures, administered 1 week before and 1 week after intervention, included the Stroke Impact Scale (SIS), the Canadian Occupational Performance Measure (COPM), the Fugl-Meyer Assessment of Motor Recovery (Fugl-Meyer [FM]), and the Box and Block Test (BB). Participant A exhibited an 11-point increase on the SIS, a 1.2-point change on each of the performance and satisfaction scores of the COPM, a 1-point increase on the FM, and no change on the BB. Participant B exhibited a 3-point increase on the SIS and no change on the COPM, FM, or BB. The participants experienced increased quality of life, a greater propensity to use their affected arm, and enhanced task performance without exhibiting motor changes. Additionally, the Core:Tx gaming device was reported by the participants to be a motivating modality in the therapy setting.
NASA Astrophysics Data System (ADS)
Kim, Taeho; Hur, Jihyun; Jeon, Sanghun
2016-05-01
Defects in oxide semiconductors not only influence the initial device performance but also affect device reliability. The front channel is the major carrier transport region during the transistor turn-on stage, therefore an understanding of defects located in the vicinity of the interface is very important. In this study, we investigated the dynamics of charge transport in a nanocrystalline hafnium-indium-zinc-oxide thin-film transistor (TFT) by short pulse I-V, transient current and 1/f noise measurement methods. We found that the fast charging behavior of the tested device stems from defects located in both the front channel and the interface, following a multi-trapping mechanism. We found that a silicon-nitride stacked hafnium-indium-zinc-oxide TFT is vulnerable to interfacial charge trapping compared with silicon-oxide counterpart, causing significant mobility degradation and threshold voltage instability. The 1/f noise measurement data indicate that the carrier transport in a silicon-nitride stacked TFT device is governed by trapping/de-trapping processes via defects in the interface, while the silicon-oxide device follows the mobility fluctuation model.
Katz, Ira; Pichelin, Marine; Montesantos, Spyridon; Kang, Min-Yeong; Sapoval, Bernard; Zhu, Kaixian; Thevenin, Charles-Philippe; McCoy, Robert; Martin, Andrew R; Caillibotte, Georges
2016-01-01
Oxygen treatment based on intermittent-flow devices with pulse delivery modes available from portable oxygen concentrators (POCs) depends on the characteristics of the delivered pulse such as volume, pulse width (the time of the pulse to be delivered), and pulse delay (the time for the pulse to be initiated from the start of inhalation) as well as a patient’s breathing characteristics, disease state, and respiratory morphology. This article presents a physiological-based analysis of the performance, in terms of blood oxygenation, of a commercial POC at different settings using an in silico model of a COPD patient at rest and during exercise. The analysis encompasses experimental measurements of pulse volume, width, and time delay of the POC at three different settings and two breathing rates related to rest and exercise. These experimental data of device performance are inputs to a physiological-based model of oxygen uptake that takes into account the real dynamic nature of gas exchange to illustrate how device- and patient-specific factors can affect patient oxygenation. This type of physiological analysis that considers the true effectiveness of oxygen transfer to the blood, as opposed to delivery to the nose (or mouth), can be instructive in applying therapies and designing new devices. PMID:27729783
Training Deep Convolutional Neural Networks with Resistive Cross-Point Devices
Gokmen, Tayfun; Onen, Murat; Haensch, Wilfried
2017-01-01
In a previous work we have detailed the requirements for obtaining maximal deep learning performance benefit by implementing fully connected deep neural networks (DNN) in the form of arrays of resistive devices. Here we extend the concept of Resistive Processing Unit (RPU) devices to convolutional neural networks (CNNs). We show how to map the convolutional layers to fully connected RPU arrays such that the parallelism of the hardware can be fully utilized in all three cycles of the backpropagation algorithm. We find that the noise and bound limitations imposed by the analog nature of the computations performed on the arrays significantly affect the training accuracy of the CNNs. Noise and bound management techniques are presented that mitigate these problems without introducing any additional complexity in the analog circuits and that can be addressed by the digital circuits. In addition, we discuss digitally programmable update management and device variability reduction techniques that can be used selectively for some of the layers in a CNN. We show that a combination of all those techniques enables a successful application of the RPU concept for training CNNs. The techniques discussed here are more general and can be applied beyond CNN architectures and therefore enables applicability of the RPU approach to a large class of neural network architectures. PMID:29066942
Training Deep Convolutional Neural Networks with Resistive Cross-Point Devices.
Gokmen, Tayfun; Onen, Murat; Haensch, Wilfried
2017-01-01
In a previous work we have detailed the requirements for obtaining maximal deep learning performance benefit by implementing fully connected deep neural networks (DNN) in the form of arrays of resistive devices. Here we extend the concept of Resistive Processing Unit (RPU) devices to convolutional neural networks (CNNs). We show how to map the convolutional layers to fully connected RPU arrays such that the parallelism of the hardware can be fully utilized in all three cycles of the backpropagation algorithm. We find that the noise and bound limitations imposed by the analog nature of the computations performed on the arrays significantly affect the training accuracy of the CNNs. Noise and bound management techniques are presented that mitigate these problems without introducing any additional complexity in the analog circuits and that can be addressed by the digital circuits. In addition, we discuss digitally programmable update management and device variability reduction techniques that can be used selectively for some of the layers in a CNN. We show that a combination of all those techniques enables a successful application of the RPU concept for training CNNs. The techniques discussed here are more general and can be applied beyond CNN architectures and therefore enables applicability of the RPU approach to a large class of neural network architectures.
Advanced plasma etch technologies for nanopatterning
NASA Astrophysics Data System (ADS)
Wise, Rich
2013-10-01
Advances in patterning techniques have enabled the extension of immersion lithography from 65/45 nm through 14/10 nm device technologies. A key to this increase in patterning capability has been innovation in the subsequent dry plasma etch processing steps. Multiple exposure techniques, such as litho-etch-litho-etch, sidewall image transfer, line/cut mask, and self-aligned structures, have been implemented to solution required device scaling. Advances in dry plasma etch process control across wafer uniformity and etch selectivity to both masking materials have enabled adoption of vertical devices and thin film scaling for increased device performance at a given pitch. Plasma etch processes, such as trilayer etches, aggressive critical dimension shrink techniques, and the extension of resist trim processes, have increased the attainable device dimensions at a given imaging capability. Precise control of the plasma etch parameters affecting across-design variation, defectivity, profile stability within wafer, within lot, and across tools has been successfully implemented to provide manufacturable patterning technology solutions. IBM has addressed these patterning challenges through an integrated total patterning solutions team to provide seamless and synergistic patterning processes to device and integration internal customers. We will discuss these challenges and the innovative plasma etch solutions pioneered by IBM and our alliance partners.
Advanced plasma etch technologies for nanopatterning
NASA Astrophysics Data System (ADS)
Wise, Rich
2012-03-01
Advances in patterning techniques have enabled the extension of immersion lithography from 65/45nm through 14/10nm device technologies. A key to this increase in patterning capability has been innovation in the subsequent dry plasma etch processing steps. Multiple exposure techniques such as litho-etch-litho-etch, sidewall image transfer, line/cut mask and self-aligned structures have been implemented to solution required device scaling. Advances in dry plasma etch process control, across wafer uniformity and etch selectivity to both masking materials and have enabled adoption of vertical devices and thin film scaling for increased device performance at a given pitch. Plasma etch processes such as trilayer etches, aggressive CD shrink techniques, and the extension of resist trim processes have increased the attainable device dimensions at a given imaging capability. Precise control of the plasma etch parameters affecting across design variation, defectivity, profile stability within wafer, within lot, and across tools have been successfully implemented to provide manufacturable patterning technology solutions. IBM has addressed these patterning challenges through an integrated Total Patterning Solutions team to provide seamless and synergistic patterning processes to device and integration internal customers. This paper will discuss these challenges and the innovative plasma etch solutions pioneered by IBM and our alliance partners.
Fu, L; Rochette, M; Ta'eed, V; Moss, D; Eggleton, B
2005-09-19
We investigate the feasibility of all-optical regeneration based on self-phase modulation in single mode As2Se3 chalcogenide fiber. By combining the chalcogenide fiber with a bandpass filter, we achieve a near step-like power transfer function with no pulse distortion. The device is shown to operate with 5.8 ps duration pulses, thus demonstrating the feasibility of this device operating with high bit-rate data signals. These results are achieved with pulse peak powers <10 W in a fully passive device, including only 2.8 m of chalcogenide fiber. We obtain an excellent agreement between theory and experiment and show that both the high nonlinearity of the chalcogenide glass along with its high normal dispersion near 1550 nm enables a significant device length reduction in comparison with silica-based devices, without compromise on the performance. We find that even for only a few meters of fiber, the large normal dispersion of the chalcogenide glass inhibits spectral oscillations that would appear with self-phase modulation alone. We measure the two photon absorption attenuation coefficient and find that it advantageously affects the device transfer function.
NASA Technical Reports Server (NTRS)
Campbell, Bryan A.; Applin, Zachary T.; Kemmerly, Guy T.
1999-01-01
An experimental investigation of the effects of leading-edge vortex management devices on the subsonic performance of a high-speed civil transport (HSCT) configuration was conducted in the Langley 14- by 22-Foot Subsonic Tunnel. Data were obtained over a Mach number range of 0.14 to 0.27, with corresponding chord Reynolds numbers of 3.08 x 10 (sup 6) to 5.47 x 10 (sup 6). The test model was designed for a cruise Mach number of 2.7. During the subsonic high-lift phase of flight, vortical flow dominates the upper surface flow structure, and during vortex breakdown, this flow causes adverse pitch-up and a reduction of usable lift. The experimental results showed that the beneficial effects of small leading-edge vortex management devices located near the model reference center were insufficient to substantially affect the resulting aerodynamic forces and moments. However, devices located at or near the wiring apex region demonstrated potential for pitch control with little effect on overall lift.
NASA Astrophysics Data System (ADS)
Cortese, Simone; Khiat, Ali; Carta, Daniela; Light, Mark E.; Prodromakis, Themistoklis
2016-01-01
Resistive random access memory (ReRAM) crossbar arrays have become one of the most promising candidates for next-generation non volatile memories. To become a mature technology, the sneak path current issue must be solved without compromising all the advantages that crossbars offer in terms of electrical performances and fabrication complexity. Here, we present a highly integrable access device based on nickel and sub-stoichiometric amorphous titanium dioxide (TiO2-x), in a metal insulator metal crossbar structure. The high voltage margin of 3 V, amongst the highest reported for monolayer selector devices, and the good current density of 104 A/cm2 make it suitable to sustain ReRAM read and write operations, effectively tackling sneak currents in crossbars without compromising fabrication complexity in a 1 Selector 1 Resistor (1S1R) architecture. Furthermore, the voltage margin is found to be tunable by an annealing step without affecting the device's characteristics.
Normally-off Al2O3/GaN MOSFET: Role of border traps on the device transport characteristics
NASA Astrophysics Data System (ADS)
Wang, Hongyue; Wang, Jinyan; Liu, Jingqian; He, Yandong; Wang, Maojun; Yu, Min; Wu, Wengang
2018-03-01
Based on the self-terminating gate recess technique, two different processes featuring gate-recess-first (GF) and ohmic-contact-first (OF) were proposed for E-mode Al2O3/GaN MOSFETs. Increased maximum drain current (Idmax) ∼30% (420 vs 325 mA/mm), field-effect mobility (μFEmax) ∼67% (150 vs 90 cm2/Vs) and reduced on-state resistance (Ron) ∼42% (9.7 vs 16.8 Ω·mm) were observed in the devices fabricated by GF process. Such significant performance difference of GF- and OF-devices resulted from the presence of border traps at Al2O3/GaN interface with a time constant ∼7 × 10-6 s. Experimental results indicated that: (1) the near interface border traps in Al2O3 dielectric significantly affect device channel mobility; (2) a high temperature post-deposition annealing process could effective suppress generation of border traps.
NASA Astrophysics Data System (ADS)
Yang, Liping; Wang, Xiaoping; Kou, Zhiqi; Ji, Changyan
2017-04-01
The electro-optical properties of the blue phosphorescent organic light-emitting diodes (PHOLEDs) can be affected by the stepwise doping structure in the emitting layer (EML). A series of multi-EML devices with different doping concentration of blue dopant (FIrpic) are fabricated. The effect of the stepwise doping structure close to the electron transport layer is more obvious than that close to the hole transport layer. When the doping concentration increases gradually from the hole injection side to the electron injection side, the maximum values of the luminance, current and power efficiency can reach to 9745 cd/m2 (at 9 V), 32.0 cd/A and 25.1 lm/W in the device with the asymmetric tri-EML structure, which is improved by about 10% compared with that in the bi-EML device. When the number of the EML is four, the performance of the device becomes worse because of the interface effect resulting from different concentration of dopant.
Wide-area-distributed storage system for a multimedia database
NASA Astrophysics Data System (ADS)
Ueno, Masahiro; Kinoshita, Shigechika; Kuriki, Makato; Murata, Setsuko; Iwatsu, Shigetaro
1998-12-01
We have developed a wide-area-distribution storage system for multimedia databases, which minimizes the possibility of simultaneous failure of multiple disks in the event of a major disaster. It features a RAID system, whose member disks are spatially distributed over a wide area. Each node has a device, which includes the controller of the RAID and the controller of the member disks controlled by other nodes. The devices in the node are connected to a computer, using fiber optic cables and communicate using fiber-channel technology. Any computer at a node can utilize multiple devices connected by optical fibers as a single 'virtual disk.' The advantage of this system structure is that devices and fiber optic cables are shared by the computers. In this report, we first described our proposed system, and a prototype was used for testing. We then discussed its performance; i.e., how to read and write throughputs are affected by data-access delay, the RAID level, and queuing.
[Point-of-care Coagulation Testing in Neurosurgery].
Adam, Elisabeth Hannah; Füllenbach, Christoph; Lindau, Simone; Konczalla, Jürgen
2018-06-01
Disorders of the coagulation system can seriously impact the clinical course and outcome of neurosurgical patients. Due to the anatomical location of the central nervous system within the closed skull, bleeding complications can lead to devastating consequences such as an increase in intracranial pressure or enlargement of intracranial hematoma. Point-of-care (POC) devices for the testing of haemostatic parameters have been implemented in various fields of medicine. Major advantages of these devices are that results are available quickly and that analysis can be performed at the bedside, directly affecting patient management. POC devices allow identification of increased bleeding tendencies and therefore may enable an assessment of hemorrhagic risks in neurosurgical patients. Although data regarding the use of POC testing in neurosurgical patients are limited, they suggest that coagulation testing and hemostatic therapy using POC devices might have beneficial effects in this patient population. This article provides an overview of the application of point-of-care coagulation testing in clinical practice in neurosurgical patients. Georg Thieme Verlag KG Stuttgart · New York.
Large contact noise in graphene field-effect transistors
NASA Astrophysics Data System (ADS)
Karnatak, Paritosh; Sai, Phanindra; Goswami, Srijit; Ghatak, Subhamoy; Kaushal, Sanjeev; Ghosh, Arindam
Fluctuations in the electrical resistance at the interface of atomically thin materials and metals, or the contact noise, can adversely affect the device performance but remains largely unexplored. We have investigated contact noise in graphene field effect transistors of varying device geometry and contact configuration, with channel carrier mobility ranging from 5,000 to 80,000 cm2V-1s-1. A phenomenological model developed for contact noise due to current crowding for two dimensional conductors, shows a dominant contact contribution to the measured resistance noise in all graphene field effect transistors when measured in the two-probe or invasive four probe configurations, and surprisingly, also in nearly noninvasive four probe (Hall bar) configuration in the high mobility devices. We identify the fluctuating electrostatic environment of the metal-channel interface as the major source of contact noise, which could be generic to two dimensional material-based electronic devices. The work was financially supported by the Department of Science and Technology, India and Tokyo Electron Limited.
ERIC Educational Resources Information Center
Riley McKee, Megan
2012-01-01
Floating describes the act of staff moving from one unit to another based on the needs of the patients in a hospital. Many staff who float to different units express negative feelings, including anxiety and lack in self-efficacy. However, floating is both an economical and efficient method to use staff across the hospital, especially with current…
Design of optimal buffer layers for CuInGaSe2 thin-film solar cells(Conference Presentation)
NASA Astrophysics Data System (ADS)
Lordi, Vincenzo; Varley, Joel B.; He, Xiaoqing; Rockett, Angus A.; Bailey, Jeff; Zapalac, Geordie H.; Mackie, Neil; Poplavskyy, Dmitry; Bayman, Atiye
2016-09-01
Optimizing the buffer layer in manufactured thin-film PV is essential to maximize device efficiency. Here, we describe a combined synthesis, characterization, and theory effort to design optimal buffers based on the (Cd,Zn)(O,S) alloy system for CIGS devices. Optimization of buffer composition and absorber/buffer interface properties in light of several competing requirements for maximum device efficiency were performed, along with process variations to control the film and interface quality. The most relevant buffer properties controlling performance include band gap, conduction band offset with absorber, dopability, interface quality, and film crystallinity. Control of an all-PVD deposition process enabled variation of buffer composition, crystallinity, doping, and quality of the absorber/buffer interface. Analytical electron microscopy was used to characterize the film composition and morphology, while hybrid density functional theory was used to predict optimal compositions and growth parameters based on computed material properties. Process variations were developed to produce layers with controlled crystallinity, varying from amorphous to fully epitaxial, depending primarily on oxygen content. Elemental intermixing between buffer and absorber, particularly involving Cd and Cu, also is controlled and significantly affects device performance. Secondary phase formation at the interface is observed for some conditions and may be detrimental depending on the morphology. Theoretical calculations suggest optimal composition ranges for the buffer based on a suite of computed properties and drive process optimizations connected with observed film properties. Prepared by LLNL under Contract DE-AC52-07NA27344.
Grisorio, Roberto; Iacobellis, Rosabianca; Listorti, Andrea; De Marco, Luisa; Cipolla, Maria Pia; Manca, Michele; Rizzo, Aurora; Abate, Antonio; Gigli, Giuseppe; Suranna, Gian Paolo
2017-07-26
Due to a still limited understanding of the reasons making 2,2',7,7'-tetrakis(N,N-di-p-methoxyphenylamine)-9,9'-spirobifluorene (Spiro-OMeTAD) the state-of-the-art hole-transporting material (HTM) for emerging photovoltaic applications, the molecular tailoring of organic components for perovskite solar cells (PSCs) lacks in solid design criteria. Charge delocalization in radical cationic states can undoubtedly be considered as one of the essential prerequisites for an HTM, but this aspect has been investigated to a relatively minor extent. In marked contrast with the 3-D structure of Spiro-OMeTAD, truxene-based HTMs Trux1 and Trux2 have been employed for the first time in PSCs fabricated with a direct (n-i-p) or inverted (p-i-n) architecture, exhibiting a peculiar behavior with respect to the referential HTM. Notwithstanding the efficient hole extraction from the perovskite layer exhibited by Trux1 and Trux2 in direct configuration devices, their photovoltaic performances were detrimentally affected by their poor hole transport. Conversely, an outstanding improvement of the photovoltaic performances in dopant-free inverted configuration devices compared to Spiro-OMeTAD was recorded, ascribable to the use of thinner HTM layers. The rationalization of the photovoltaic performances exhibited by different configuration devices discussed in this paper can provide new and unexpected prospects for engineering the interface between the active layer of perovskite-based solar cells and the hole transporters.
Shahrokhi, A; Burghele, B D; Fábián, F; Kovács, T
2015-12-01
The influence of high geogenic carbon dioxide concentrations on monitoring devices might present a significant challenge to the measurement of radon concentrations in environments with a high level of carbon dioxide concentration such as volcano sites, mofettes, caves, etc. In this study, the influence of carbon dioxide concentration on several different types of radon monitor devices - including Alpha Spectrometry (Sarad RTM 2200, EQF 3220, RAD7), Ionizing Chamber (AlphaGUARD PQ2000 PRO) and Active Cell (Active scintillation cell, Pylon 300A) - was examined to represent new aspects of radon measuring in environments with carbon dioxide. In light of the results, all measuring devices were exposed to variable conditions affected by carbon dioxide concentration, except for the AlphaGUARD, which was kept in a steady state throughout the experiment. It was observed that alpha spectroscopy devices were affected by carbon dioxide, since measured radon concentrations decreased in the presence of 70% and 90% carbon dioxide concentrations by 26.5 ± 2% and 14.5 ± 2.5% for EQF 3220, and 32 ± 2% and 35.5 ± 2% for RTM 2200. However, the ionizing chamber instrument was unaffected by changes in carbon dioxide concentration. It was determined that the RAD7 performed relatively inefficiently in the presence of carbon dioxide concentrations higher than 67% by an overall efficiency factor of approximately 0.52, confirming that it is not an admissible radon monitor instrument in environments with high carbon dioxide concentrations. Copyright © 2015 Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2014 CFR
2014-07-01
... monitoring requirements for my storage vessel or centrifugal compressor affected facility? 60.5417 Section 60... requirements for my storage vessel or centrifugal compressor affected facility? You must meet the applicable... standards for your storage vessel or centrifugal compressor affected facility. (a) For each control device...
NASA Astrophysics Data System (ADS)
Szelag, Bertrand; Abraham, Alexis; Brision, Stéphane; Gindre, Paul; Blampey, Benjamin; Myko, André; Olivier, Segolene; Kopp, Christophe
2017-05-01
Silicon photonic is becoming a reality for next generation communication system addressing the increasing needs of HPC (High Performance Computing) systems and datacenters. CMOS compatible photonic platforms are developed in many foundries integrating passive and active devices. The use of existing and qualified microelectronics process guarantees cost efficient and mature photonic technologies. Meanwhile, photonic devices have their own fabrication constraints, not similar to those of cmos devices, which can affect their performances. In this paper, we are addressing the integration of PN junction Mach Zehnder modulator in a 200mm CMOS compatible photonic platform. Implantation based device characteristics are impacted by many process variations among which screening layer thickness, dopant diffusion, implantation mask overlay. CMOS devices are generally quite robust with respect to these processes thanks to dedicated design rules. For photonic devices, the situation is different since, most of the time, doped areas must be carefully located within waveguides and CMOS solutions like self-alignment to the gate cannot be applied. In this work, we present different robust integration solutions for junction-based modulators. A simulation setup has been built in order to optimize of the process conditions. It consist in a Mathlab interface coupling process and device electro-optic simulators in order to run many iterations. Illustrations of modulator characteristic variations with process parameters are done using this simulation setup. Parameters under study are, for instance, X and Y direction lithography shifts, screening oxide and slab thicknesses. A robust process and design approach leading to a pn junction Mach Zehnder modulator insensitive to lithography misalignment is then proposed. Simulation results are compared with experimental datas. Indeed, various modulators have been fabricated with different process conditions and integration schemes. Extensive electro-optic characterization of these components will be presented.
Designing for scale: development of the ReMotion Knee for global emerging markets.
Hamner, Samuel R; Narayan, Vinesh G; Donaldson, Krista M
2013-09-01
Amputees living in developing countries have a profound need for affordable and reliable lower limb prosthetic devices. The World Health Organization estimates there are approximately 30 million amputees living in low-income countries, with up to 95% lacking access to prosthetic devices. Effective prosthetics can significantly affect the lives of these amputees by increasing opportunity for employment and providing improvements to long-term health and well-being. However, current solutions are inadequate: state-of-the-art solutions from the US and Europe are cost-prohibitive, while low-cost devices have been challenged by poor quality and/or unreliable performance, and have yet to achieve large scale impact. The introduction of new devices is hampered by the lack of a cohesive prosthetics industry in low-income areas; the current network of low-cost prosthetic clinics is informal and loosely organized with significant disparities in geography, patient volume and demographics, device procurement, clinical and logistical infrastructure, and funding. At D-Rev (Design Revolution) we are creating the ReMotion Knee, which is an affordable polycentric prosthetic knee joint that performs on par with devices in more industrialized regions, like the US and Europe. As of September 2012, over 4200 amputees have been fitted with the initial version of the ReMotion Knee through a partnership with the JaipurFoot Organization, with an 79% compliance rate after 2 years. We are currently scaling production of the ReMotion Knee using centralized manufacturing and distribution to serve the existing clinics in low-income countries and increase the availability of devices for amputees without access to appropriate care. At D-Rev, we develop products that target these customers through economically-sustainable models and provide a measurable impact in the lives of the world's amputees.
Schober, P; Krage, R; Lagerburg, V; Van Groeningen, D; Loer, S A; Schwarte, L A
2014-04-01
Current cardiopulmonary resuscitation (CPR)-guidelines recommend an increased chest compression depth and rate compared to previous guidelines, and the use of automatic feedback devices is encouraged. However, it is unclear whether this compression depth can be maintained at an increased frequency. Moreover, the underlying surface may influence accuracy of feedback devices. We investigated compression depths over time and evaluated the accuracy of a feedback device on different surfaces. Twenty-four volunteers performed four two-minute blocks of CPR targeting at current guideline recommendations on different surfaces (floor, mattress, 2 backboards) on a patient simulator. Participants rested for 2 minutes between blocks. Influences of time and different surfaces on chest compression depth (ANOVA, mean [95% CI]) and accuracy of a feedback device to determine compression depth (Bland-Altman) were assessed. Mean compression depth did not reach recommended depth and decreased over time during all blocks (first block: from 42 mm [39-46 mm] to 39 mm [37-42 mm]). A two-minute resting period was insufficient to restore compression depth to baseline. No differences in compression depth were observed on different surfaces. The feedback device slightly underestimated compression depth on the floor (bias -3.9 mm), but markedly overestimated on the mattress (bias +12.6 mm). This overestimation was eliminated after correcting compression depth by a second sensor between manikin and mattress. Strategies are needed to improve chest compression depth, and more than two providers should alternate with chest compressions. The underlying surface does not necessarily adversely affect CPR performance but influences accuracy of feedback devices. Accuracy is improved by a second, posterior, sensor.
NASA Astrophysics Data System (ADS)
Varley, J. B.; Lordi, V.; Ogitsu, T.; Deangelis, A.; Horsley, K.; Gaillard, N.
2018-04-01
Understanding the impact of impurities in solar absorbers is critical to engineering high-performance in devices, particularly over extended periods of time. Here, we use hybrid functional calculations to explore the role of hydrogen interstitial (Hi) defects in the electronic properties of a number of attractive solar absorbers within the chalcopyrite and kesterite families to identify how this common impurity may influence device performance. Our results identify that Hi can inhibit the highly p-type conditions desirable for several higher-band gap absorbers and that H incorporation could detrimentally affect the open-circuit voltage (Voc) and limit device efficiencies. Additionally, we find that Hi can drive the Fermi level away from the valence band edge enough to lead to n-type conductivity in a number of chalcopyrite and kesterite absorbers, particularly those containing Ag rather than Cu. We find that these effects can lead to interfacial Fermi-level pinning that can qualitatively explain the observed performance in high-Ga content CIGSe solar cells that exhibit saturation in the Voc with increasing band gap. Our results suggest that compositional grading rather than bulk alloying, such as by creating In-rich surfaces, may be a better strategy to favorably engineering improved thin-film photovoltaics with larger-band gap absorbers.
Evidence of soft bound behaviour in analogue memristive devices for neuromorphic computing.
Frascaroli, Jacopo; Brivio, Stefano; Covi, Erika; Spiga, Sabina
2018-05-08
The development of devices that can modulate their conductance under the application of electrical stimuli constitutes a fundamental step towards the realization of synaptic connectivity in neural networks. Optimization of synaptic functionality requires the understanding of the analogue conductance update under different programming conditions. Moreover, properties of physical devices such as bounded conductance values and state-dependent modulation should be considered as they affect storage capacity and performance of the network. This work provides a study of the conductance dynamics produced by identical pulses as a function of the programming parameters in an HfO 2 memristive device. The application of a phenomenological model that considers a soft approach to the conductance boundaries allows the identification of different operation regimes and to quantify conductance modulation in the analogue region. Device non-linear switching kinetics is recognized as the physical origin of the transition between different dynamics and motivates the crucial trade-off between degree of analog modulation and memory window. Different kinetics for the processes of conductance increase and decrease account for device programming asymmetry. The identification of programming trade-off together with an evaluation of device variations provide a guideline for the optimization of the analogue programming in view of hardware implementation of neural networks.
Park, Woon Ik; Kim, Jong Min; Jeong, Jae Won; ...
2015-03-17
Phase change memory (PCM) is one of the most promising candidates for next-generation nonvolatile memory devices because of its high speed, excellent reliability, and outstanding scalability. But, the high switching current of PCM devices has been a critical hurdle to realize low-power operation. Although one solution is to reduce the switching volume of the memory, the resolution limit of photolithography hinders further miniaturization of device dimensions. Here, we employed unconventional self-assembly geometries obtained from blends of block copolymers (BCPs) to form ring-shaped hollow PCM nanostructures with an ultrasmall contact area between a phase-change material (Ge 2Sb 2Te 5) and amore » heater (TiN) electrode. The high-density (approximately 0.1 terabits per square inch) PCM nanoring arrays showed extremely small switching current of 2-3 mu A. Furthermore, the relatively small reset current of the ring-shaped PCM compared to the pillar-shaped devices is attributed to smaller switching volume, which is well supported by electro-thermal simulation results. Our approach may also be extended to other nonvolatile memory device applications such as resistive switching memory and magnetic storage devices, where the control of nanoscale geometry can significantly affect device performances.« less
Kim, Hyojin; Choi, Jee Woong; Kim, Jun Young; Shin, Jung Won; Lee, Seok-Jong; Huh, Chang-Hun
2013-08-01
Androgenetic alopecia (AGA) is a common disorder affecting men and women. Finasteride and minoxidil are well-known, effective treatment methods, but patients who exhibit a poor response to these methods have no additional adequate treatment modalities. To evaluate the efficacy and safety of a low-level light therapy (LLLT) device for the treatment of AGA. This study was designed as a 24-week, randomized, double-blind, sham device-controlled trial. Forty subjects with AGA were enrolled and scheduled to receive treatment with a helmet-type, home-use LLLT device emitting wavelengths of 630, 650, and 660 nm or a sham device for 18 minutes daily. Investigator and subject performed phototrichogram assessment (hair density and thickness) and global assessment of hair regrowth for evaluation. After 24 weeks of treatment, the LLLT group showed significantly greater hair density than the sham device group. Mean hair diameter improved statistically significantly more in the LLLT group than in the sham device group. Investigator global assessment showed a significant difference between the two groups, but that of the subject did not. No serious adverse reactions were detected. LLLT could be an effective treatment for AGA. © 2013 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Linke, J.
2006-04-01
The plasma exposed components in existing and future fusion devices are strongly affected by the plasma material interaction processes. These mechanisms have a strong influence on the plasma performance; in addition they have major impact on the lifetime of the plasma facing armour and the joining interface between the plasma facing material (PFM) and the heat sink. Besides physical and chemical sputtering processes, high heat quasi-stationary fluxes during normal and intense thermal transients are of serious concern for the engineers who develop reliable wall components. In addition, the material and component degradation due to intense fluxes of energetic neutrons is another critical issue in D-T-burning fusion devices which requires extensive R&D. This paper presents an overview on the materials development and joining, the testing of PFMs and components, and the analysis of the neutron irradiation induced degradation.
NASA Astrophysics Data System (ADS)
Serranti, S.; Bonifazi, G.; Luciani, V.; D'Aniello, L.
2017-05-01
The present work explores the possible utilization of hyperspectral devices, following a proximity based approach, for the diagnosis of Peronospora infection in the vineyards. It compares the performance of two hyperspectral cameras, characterized by different spectral acquisition ranges, in the identification of different levels of infection as detectable from the analysis of the leaf surface. For this purpose, healthy grapevine leaves and leaves affected by a different grade of Peronospora infection have been acquired in laboratory conditions using two different sensing devices: a Specim Imspector V10™ and a Specim Spectral Camera N17™ working in the region between 400-1000 nm and 1000-1700 nm, respectively. A Partial Least Squares Discriminant Analysis (PLS-DA) model has been built to perform the classification of healthy, infected and necrotic leaves.
Facile Dry Surface Cleaning of Graphene by UV Treatment
NASA Astrophysics Data System (ADS)
Kim, Jin Hong; Haidari, Mohd Musaib; Choi, Jin Sik; Kim, Hakseong; Yu, Young-Jun; Park, Jonghyurk
2018-05-01
Graphene has been considered an ideal material for application in transparent lightweight wearable electronics due to its extraordinary mechanical, optical, and electrical properties originating from its ordered hexagonal carbon atomic lattice in a layer. Precise surface control is critical in maximizing its performance in electronic applications. Graphene grown by chemical vapor deposition is widely used but it produces polymeric residue following wet/chemical transfer process, which strongly affects its intrinsic electrical properties and limits the doping efficiency by adsorption. Here, we introduce a facile dry-cleaning method based on UV irradiation to eliminate the organic residues even after device fabrication. Through surface topography, Raman analysis, and electrical transport measurement characteristics, we confirm that the optimized UV treatment can recover the clean graphene surface and improve graphene-FET performance more effectively than thermal treatment. We propose our UV irradiation method as a systematically controllable and damage-free post process for application in large-area devices.
NASA Astrophysics Data System (ADS)
Arab Bafrani, Hamidreza; Ebrahimi, Mahdi; Bagheri Shouraki, Saeed; Moshfegh, Alireza Z.
2018-01-01
Memristor devices have attracted tremendous interest due to different applications ranging from nonvolatile data storage to neuromorphic computing units. Exploring the role of surface roughness of the bottom electrode (BE)/active layer interface provides useful guidelines for the optimization of the memristor switching performance. This study focuses on the effect of surface roughness of the BE electrode on the switching characteristics of Au/TiO2/Au three-layer memristor devices. An optimized wet-etching treatment condition was found to modify the surface roughness of the Au BE where the measurement results indicate that the roughness of the Au BE is affected by both duration time and solution concentrations of the wet-etching process. Then we fabricated arrays of TiO2-based nanostructured memristors sandwiched between two sets of cross-bar Au electrode lines (junction area 900 μm2). The results revealed a reduction in the working voltages in current-voltage characteristic of the device performance when increasing the surface roughness at the Au(BE)/TiO2 active layer interface. The set voltage of the device (Vset) significantly decreased from 2.26-1.93 V when we increased the interface roughness from 4.2-13.1 nm. The present work provides information for better understanding the switching mechanism of titanium-dioxide-based devices, and it can be inferred that enhancing the roughness of the Au BE/TiO2 active layer interface leads to a localized non-uniform electric field distribution that plays a vital role in reducing the energy consumption of the device.
Sorbello, Massimiliano; Petrini, Flavia
2017-04-01
In the crowded world of supraglottic airway devices (SADs), many papers compare the easiness of insertion based on the different endpoints of an operator's satisfaction: first pass success, ventilation effectiveness, complications and morbidity. Proseal LMA ™ (Laryngeal Mask Airway, Teleflex Medical, Dublin, Ireland) has been extensively studied because on one hand it has a steeper learning curve and more complex insertion when compared with other SADs and on the other hand many alternative techniques are available to facilitate insertion. This research is part of a larger body of studies exploring the issue that some devices are more difficult to insert because of many features related to sizing, constructive material, airway conduit and cuff design, performance and last but not least experience. Nevertheless, the biggest question might be the search for a systematic categorization of insertion difficulty features and identification of criteria allowing the choice for the best device and consequently for the best insertion technique. Given that, as a result of many intrinsic characteristics of the device we are using, insertion might become the secondary issue to be considered only after we clearly identify what makes it difficult, and to be counterbalanced on the results we expect from the device, performance we can achieve and degree of airway protection it could grant. The aim of this narrative review is to consider which factors might affect or condition SAD insertion difficulty and to try identifying some criteria addressing physicians pertaining to the use of SADs in clinical practice.
Studying Light Color using White LED Lighting
NASA Astrophysics Data System (ADS)
Yamagishi, Misako; Yamaba, Kazuo; Nagata, Manori; Kubo, Chiho; Nokura, Kunihiro
Recently, white Light Emitting Diodes (LEDs) are receiving attention worldwide as new lighting devices. This study examined effects of a lighting application on performance using white LEDs. The light color—the correlated color temperature (CCT) —was assessed. It affected to psychological states and physiological conditions. Three CCT conditions were respectively set for the experiment: 2500 K, 5000 K, and 8200 K. In all, 20 younger subjects (20-30 years old), 15 middle-aged to elderly subjects (45-60 years old) and 12 elderly subjects (over 65 years-old) participated. They were presented a Numerical Verification (NV) task for performance measurement. The psychological states on performance were evaluated using the lighting assessment questionnaire. The physiological conditions were recorded using an electrocardiograph. Results show that the effects of CCT differ among age groups. Especially, the performance of younger subjects might differ from CCT conditions; elderly subjects are affected by CCT condition because of their visual acuity or response to contrast of objects.
Bowen, Raffick A R; Adcock, Dorothy M
2016-12-01
Blood collection tubes (BCTs) are an often under-recognized variable in the preanalytical phase of clinical laboratory testing. Unfortunately, even the best-designed and manufactured BCTs may not work well in all clinical settings. Clinical laboratories, in collaboration with healthcare providers, should carefully evaluate BCTs prior to putting them into clinical use to determine their limitations and ensure that patients are not placed at risk because of inaccuracies due to poor tube performance. Selection of the best BCTs can be achieved through comparing advertising materials, reviewing the literature, observing the device at a scientific meeting, receiving a demonstration, evaluating the device under simulated conditions, or testing the device with patient samples. Although many publications have discussed method validations, few detail how to perform experiments for tube verification and validation. This article highlights the most common and impactful variables related to BCTs and discusses the validation studies that a typical clinical laboratory should perform when selecting BCTs. We also present a brief review of how in vitro diagnostic devices, particularly BCTs, are regulated in the United States, the European Union, and Canada. The verification and validation of BCTs will help to avoid the economic and human costs associated with incorrect test results, including poor patient care, unnecessary testing, and delays in test results. We urge laboratorians, tube manufacturers, diagnostic companies, and other researchers to take all the necessary steps to protect against the adverse effects of BCT components and their additives on clinical assays. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Santarpia, Giuseppe; Passafaro, Francesco; Pasceri, Eugenia; Mongiardo, Annalisa; Curcio, Antonio; Indolfi, Ciro
2018-05-01
Inadvertent pacemaker/defibrillator lead placement into the left ventricle is an unusual cardiac device-related complication and its diagnosis is not always easy and often misunderstood. Thromboembolic events are frequently associated with this procedural complication. Percutaneous lead extraction should be performed when diagnosis is made early after device implantation while long-life oral anticoagulation is a wise option when the diagnosis is delayed and the lead is not removed. A 65-year-old man affected by dilated cardiomyopathy, previously treated with a percutaneous mitral valve repair, with 2 MitraClip devices, and later with dual chamber cardioverter/defibrillator implantation, returned in outpatient clinics 2 months after discharge for deterioration of dyspnea; transthoracic echocardiography revealed that the shock lead had been accidentally placed in the apex of the left ventricle. The unintentional lead malposition through the iatrogenic atrial septal defect and its presence into the mitral valve orifice, together with the 2 clip devices implanted, generated an acceleration of transvalvular diastolic flow, determining a moderate stenosis of the mitral valve, as well as promoting a worsening of the degree of valvular regurgitation. Oral anticoagulation therapy was started and a mechanical lead extraction was percutaneously performed. A new defibrillator lead was later appropriately positioned in the apex of the right ventricle. The patient was discharged 3 days after intervention and the follow-up, performed 1 month after discharge, was uneventful. Complex interventional procedures and implantation of multiple devices can increase procedural troubles and the risk of mechanical complications related to pacemaker/defibrillator implantation. Careful observation of the QRS complex morphology on the electrocardiogram (ECG), during paced rhythm, and the achievement of the echocardiographic examination, in the postprocedural phase, allow an early diagnosis of lead malposition.
McBride, Deborah L; LeVasseur, Sandra A
2017-04-13
Coincident with the proliferation of employer-provided mobile communication devices, personal communication devices, including basic and enhanced mobile phones (smartphones) and tablet computers that are owned by the user, have become ubiquitous among registered nurses working in hospitals. While there are numerous benefits of personal communication device use by nurses at work, little is known about the impact of these devices on in-patient care. Our aim was to examine how hospital-registered nurses use their personal communication devices while doing both work-related and non‒work-related activities and to assess the impact of these devices on in-patient care. A previously validated survey was emailed to 14,797 members of two national nursing organizations. Participants were asked about personal communication device use and their opinions about the impact of these devices on their own and their colleagues' work. Of the 1268 respondents (8.57% response rate), only 5.65% (70/1237) never used their personal communication device at work (excluding lunch and breaks). Respondents self-reported using their personal communication devices at work for work-related activities including checking or sending text messages or emails to health care team members (29.02%, 363/1251), as a calculator (25.34%, 316/1247), and to access work-related medical information (20.13%, 251/1247). Fewer nurses reported using their devices for non‒work-related activities including checking or sending text messages or emails to friends and family (18.75%, 235/1253), shopping (5.14%, 64/1244), or playing games (2.73%, 34/1249). A minority of respondents believe that their personal device use at work had a positive effect on their work including reducing stress (29.88%, 369/1235), benefiting patient care (28.74%, 357/1242), improving coordination of patient care among the health care team (25.34%, 315/1243), or increasing unit teamwork (17.70%, 220/1243). A majority (69.06%, 848/1228) of respondents believe that on average personal communication devices have a more negative than positive impact on patient care and 39.07% (481/1231) reported that personal communication devices were always or often a distraction while working. Respondents acknowledged their own device use negatively affected their work performance (7.56%, 94/1243), or caused them to miss important clinical information (3.83%, 47/1225) or make a medical error (0.90%, 11/1218). Respondents reported witnessing another nurse's use of devices negatively affect their work performance (69.41%, 860/1239), or cause them to miss important clinical information (30.61%, 378/1235) or make a medical error (12.51%, 155/1239). Younger respondents reported greater device use while at work than older respondents and generally had more positive opinions about the impact of personal communication devices on their work. The majority of registered nurses believe that the use of personal communication devices on hospital units raises significant safety issues. The high rate of respondents who saw colleagues distracted by their devices compared to the rate who acknowledged their own distraction may be an indication that nurses are unaware of their own attention deficits while using their devices. There were clear generational differences in personal communication device use at work and opinions about the impact of these devices on patient care. Professional codes of conduct for personal communication device use by hospital nurses need to be developed that maximize the benefits of personal communication device use, while reducing the potential for distraction and adverse outcomes. ©Deborah L McBride, Sandra A LeVasseur. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 13.04.2017.
Carlson, Dawn S; Thompson, Merideth J; Crawford, Wayne S; Boswell, Wendy R; Whitten, Dwayne
2017-12-07
The use of mobile technology for work purposes during family time has been found to affect employees' work and family lives. Using a matched sample of 344 job incumbents and their spouses, we examined the role of mobile device (MD) use for work during family time in the job incumbent-spouse relationship and how this MD use crosses over to affect the spouse's work life. Integrating the work-home resources model with family systems theory, we found that as job incumbents engage in MD use for work during family time, work-to-family conflict increases, as does the combined experience of relationship tension between job incumbents and spouses. This tension serves as a crossover mechanism, which then contributes to spouses' experience of family-to-work conflict and, subsequently, family spills over to work outcomes for the spouse in the form of reduced job satisfaction and performance. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Carbon nanotube and graphene device modeling and simulation
NASA Astrophysics Data System (ADS)
Yoon, Young Ki
The performance of the semiconductors has been improved and the price has gone down for decades. It has been continuously scaled down in size year by year, and now it encounters the fundamental scaling limit. We, therefore, should prepare a new era beyond the conventional semiconductor technologies. One of the most promising devices is possible by carbon nanotube (CNT) or graphene nanoribbon (GNR) in terms of its excellent charge transport properties. Their fundamental material properties and device physics are totally different to those of the conventional devices. In this nano-regime, more sophisticated device modeling and simulation are really needed to elucidate nano-device operation and to save our resources from errors. The numerical simulation works in this dissertation will provide novel view points on the emerging devices. In this dissertation, CNT and GNR devices are numerically studied. The first part of this work is on CNT devices, and a common structure of CNT device has CNT channel, metal source and drain contacts, and gate electrode. We investigate the strain, geometry, and scattering effects on the device performance of CNT field-effect transistors (FETs). It is shown that even a small amount of strain can result in a large effect on the performance of CNTFETs due to the variation of the bandgap and band-structure-limited velocity. A type of strain which produces a larger bandgap results in increased Schottky barrier (SB) height and decreased band-structure-limited velocity, and hence a smaller minimum leakage current, smaller on current, larger maximum achievable Ion/Ioff, and larger intrinsic delay. We also examine geometry effect of partial gate CNTFETs. In the growth process of vertical CNT, underlap between the gate and the bottom electrode is advantageous for transistor operation because it suppresses ambipolar conduction of SBFETs. Both n-type and p-type transistor operations with balanced performance metrics can be achieved on a single partial gate FET by using proper bias schemes. The effect of phonon scattering on the intrinsic delay and cut-off frequency of Schottky barrier CNTFETs is also examined. Carriers are mostly scattered by optical and zone boundary phonons beyond the beginning of the channel. The scattering has a small direct effect on the DC on current of the CNTFET, but it results in significant decrease of intrinsic cut-off frequency and increase of intrinsic delay. Semiconducting CNT is useful for the channel in CNTFETs, whereas metallic CNT can be used as an electrode. If a porous CNT film is used as a source electrode, vertical thin-film transistors (TFTs) can be constructed. Vertical organic FET (OFET) shows clear transistor switching behavior allowing orders of magnitude modulation of the source-drain current even in the presence of electrostatic screening by the source electrode. The channel length should be carefully engineered due to the trade-off between device characteristics in the subthreshold and above-threshold regions. The second subject is device simulations of GNRFETs. Even though GNR is also graphene-based quasi-1D nanostructure like CNT, the differences in shape, boundary condition, and existence of edges and dangling bonds make it operate in a different way. Atomistic 3D simulation study of the performance of GNR SBFETs is presented. The impacts of non-idealities on device performance have been investigated. The edges of GNR, which do not exist in CNT, can be advantages or disadvantages. If an appropriate control by different edge atoms is possible, it would be definitely positive. Totally new electronic band structure is obtained by different edge-termination atoms. In addition, only a fraction of impurity atom can also much affect on the material properties of GNR. In order to perform device simulations of non-uniform GNR devices, multiscale simulation scheme can be used in non-equilibrium Green's function (NEGF) formalism and density-functional method.
The effects of radiation on the outer planets grand tour
NASA Technical Reports Server (NTRS)
1971-01-01
A handbook is presented which was designed to accompany an oral presentation on the effects of radiation on the outer planets grand tour (OPGT). A summary of OPGT radiation environments expected from natural sources and the radioisotope thermoelectric generators and basic radiation effects and processes are reviewed, and ionization and displacement effects are examined. The presentation summarizes the effects of radiation on miscellaneous spacecraft materials and devices. The annealing and hardening of electronics are described. Special emphasis is placed on microcircuits. Mathematical modeling of circuits affected by radiation and radiation environmental testing are discussed. A review of means of evaluating the performance and correcting failures of irradiated devices is also presented.
Two-pole microring weight banks.
Tait, Alexander N; Wu, Allie X; Ferreira de Lima, Thomas; Nahmias, Mitchell A; Shastri, Bhavin J; Prucnal, Paul R
2018-05-15
Weighted addition is an elemental multi-input to single-output operation that can be implemented with high-performance photonic devices. Microring (MRR) weight banks bring programmable weighted addition to silicon photonics. Prior work showed that their channel limits are affected by coherent inter-channel effects that occur uniquely in weight banks. We fabricate two-pole designs that exploit this inter-channel interference in a way that is robust to dynamic tuning and fabrication variation. Scaling analysis predicts a channel count improvement of 3.4-fold, which is substantially greater than predicted by incoherent analysis used in conventional MRR devices. Advances in weight bank design expand the potential of reconfigurable analog photonic networks and multivariate microwave photonics.
Physical mechanisms affecting hot carrier-induced degradation in gallium nitride HEMTs
NASA Astrophysics Data System (ADS)
Mukherjee, Shubhajit
Gallium Nitride or GaN-based high electron mobility transistors (HEMTs) is currently the most promising device technology in several key military and civilian applications due to excellent high-power as well as high-frequency performance. Even though the performance figures are outstanding, GaN-based HEMTs are not as mature as some competing technologies, which means that establishing the reliability of the technology is important to enable use in critical applications. The objective of this research is to understand the physical mechanisms affecting the reliability of GaN HEMTs at moderate drain biases (typically VDS < 30 V in the devices considered here). The degradation in device performance is believed to be due to the formation or modification of charged defects near the interface by hydrogen depassivation processes (due to electron-activated hydrogen removal) from energetic carriers. A rate-equation describing the defect generation process is formulated based on this assumption. A combination of ensemble Monte-Carlo (EMC) simulation statistics, ab-initio density functional theory (DFT) calculations, and accelerated stress experiments is used to relate the candidate defects to the overall degradation behavior (VT and gm). The focus of this work is on the 'semi-ON' mode of transistor operation in which the degradation is usually observed to be at its highest. This semi-ON state is reasonably close to the biasing region of class-AB high power amplifiers, which are popular because of the combination of high efficiency and low distortion that is associated with this configuration. The carrier-energy distributions are obtained using an EMC simulator that was developed specifically for III-V HFETs. The rate equation is used to model the degradation at different operating conditions as well as longer stress times from the result of one short duration stress test, by utilizing the carrier-energy distribution obtained from EMC simulations for one baseline condition. This work also attempts to identify the spatial location of these defects, and how this impacts the V T shift and gm degradation of the devices.
Zhang, Jie; Xiao, Wendong; Zhang, Sen; Huang, Shoudong
2017-04-17
Device-free localization (DFL) is becoming one of the new technologies in wireless localization field, due to its advantage that the target to be localized does not need to be attached to any electronic device. In the radio-frequency (RF) DFL system, radio transmitters (RTs) and radio receivers (RXs) are used to sense the target collaboratively, and the location of the target can be estimated by fusing the changes of the received signal strength (RSS) measurements associated with the wireless links. In this paper, we will propose an extreme learning machine (ELM) approach for DFL, to improve the efficiency and the accuracy of the localization algorithm. Different from the conventional machine learning approaches for wireless localization, in which the above differential RSS measurements are trivially used as the only input features, we introduce the parameterized geometrical representation for an affected link, which consists of its geometrical intercepts and differential RSS measurement. Parameterized geometrical feature extraction (PGFE) is performed for the affected links and the features are used as the inputs of ELM. The proposed PGFE-ELM for DFL is trained in the offline phase and performed for real-time localization in the online phase, where the estimated location of the target is obtained through the created ELM. PGFE-ELM has the advantages that the affected links used by ELM in the online phase can be different from those used for training in the offline phase, and can be more robust to deal with the uncertain combination of the detectable wireless links. Experimental results show that the proposed PGFE-ELM can improve the localization accuracy and learning speed significantly compared with a number of the existing machine learning and DFL approaches, including the weighted K-nearest neighbor (WKNN), support vector machine (SVM), back propagation neural network (BPNN), as well as the well-known radio tomographic imaging (RTI) DFL approach.
Zhang, Jie; Xiao, Wendong; Zhang, Sen; Huang, Shoudong
2017-01-01
Device-free localization (DFL) is becoming one of the new technologies in wireless localization field, due to its advantage that the target to be localized does not need to be attached to any electronic device. In the radio-frequency (RF) DFL system, radio transmitters (RTs) and radio receivers (RXs) are used to sense the target collaboratively, and the location of the target can be estimated by fusing the changes of the received signal strength (RSS) measurements associated with the wireless links. In this paper, we will propose an extreme learning machine (ELM) approach for DFL, to improve the efficiency and the accuracy of the localization algorithm. Different from the conventional machine learning approaches for wireless localization, in which the above differential RSS measurements are trivially used as the only input features, we introduce the parameterized geometrical representation for an affected link, which consists of its geometrical intercepts and differential RSS measurement. Parameterized geometrical feature extraction (PGFE) is performed for the affected links and the features are used as the inputs of ELM. The proposed PGFE-ELM for DFL is trained in the offline phase and performed for real-time localization in the online phase, where the estimated location of the target is obtained through the created ELM. PGFE-ELM has the advantages that the affected links used by ELM in the online phase can be different from those used for training in the offline phase, and can be more robust to deal with the uncertain combination of the detectable wireless links. Experimental results show that the proposed PGFE-ELM can improve the localization accuracy and learning speed significantly compared with a number of the existing machine learning and DFL approaches, including the weighted K-nearest neighbor (WKNN), support vector machine (SVM), back propagation neural network (BPNN), as well as the well-known radio tomographic imaging (RTI) DFL approach. PMID:28420187
Theoretical study of modulated multi-layer SPR device for improved refractive index sensing
NASA Astrophysics Data System (ADS)
Mohapatra, Saswat; Moirangthem, Rakesh S.
2018-02-01
In the present work, a theoretical investigation of Surface Plasmon Resonance (SPR) properties of a multilayer film (Au-SiO2-Au) coated on a glass prism is being carried out. In this multilayer structure, each interface corresponds to multiple SPR modes. To obtain the maximum reflection dips in the SPR modes, the thickness of SiO2 layer is optimized by varying it from 100-600 nm. Our calculation also reveals that SPR mode corresponding to Au-ambient interface is very sensitive to the changes in the surrounding medium, least affecting other SPR modes. The sensing performance of the proposed nano-plasmonic sensor is theoretically calculated using bulk refractive index sensing. Such multilayer SPR sensing device has advantages over conventional SPR devices in terms of their bulk sensitivity and self-referencing, claiming itself as a potential candidate for the development of highly sensitive biological sensor.
Kratzer, Markus; Lasnik, Michael; Röhrig, Sören; Teichert, Christian; Deluca, Marco
2018-01-11
Lead zirconate titanate (PZT) is one of the prominent materials used in polycrystalline piezoelectric devices. Since the ferroelectric domain orientation is the most important parameter affecting the electromechanical performance, analyzing the domain orientation distribution is of great importance for the development and understanding of improved piezoceramic devices. Here, vector piezoresponse force microscopy (vector-PFM) has been applied in order to reconstruct the ferroelectric domain orientation distribution function of polished sections of device-ready polycrystalline lead zirconate titanate (PZT) material. A measurement procedure and a computer program based on the software Mathematica have been developed to automatically evaluate the vector-PFM data for reconstructing the domain orientation function. The method is tested on differently in-plane and out-of-plane poled PZT samples, and the results reveal the expected domain patterns and allow determination of the polarization orientation distribution function at high accuracy.
Short-wavelength InAlGaAs/AlGaAs quantum dot superluminescent diodes
NASA Astrophysics Data System (ADS)
Liang, De-Chun; An, Qi; Jin, Peng; Li, Xin-Kun; Wei, Heng; Wu, Ju; Wang, Zhan-Guo
2011-10-01
This paper reports the fabrication of J-shaped bent-waveguide superluminescent diodes utilizing an InAlGaAs/AlGaAs quantum dot active region. The emission spectrum of the device is centred at 884 nm with a full width at half maximum of 37 nm and an output power of 18 mW. By incorporating an Al composition into the quantum dot active region, short-wavelength superluminescent diode devices can be obtained. An intersection was found for the light power-injection current curves measured from the straight-waveguide facet and the bent-waveguide facet, respectively. The result is attributed to the conjunct effects of the gain and the additional loss of the bent waveguide. A numerical simulation is performed to verify the qualitative explanation. It is shown that bent waveguide loss is an important factor that affects the output power of J-shaped superluminescent diode devices.
Crystal growth of device quality GaAs in space
NASA Technical Reports Server (NTRS)
Gatos, H. C.; Lagowski, J.
1985-01-01
The present program has been aimed at solving the fundamental and technological problems associated with Crystal Growth of Device Quality in Space. The initial stage of the program was devoted strictly to ground-based research. The unsolved problems associated with the growth of bulk GaAs in the presence of gravitational forces were explored. Reliable chemical, structural and electronic characterization methods were developed which would permit the direct relation of the salient materials parameters (particularly those affected by zero gravity conditions) to the electronic characteristics of single crystal GaAs, in turn to device performance. These relationships are essential for the development of optimum approaches and techniques. It was concluded that the findings on elemental semiconductors Ge and Si regarding crystal growth, segregation, chemical composition, defect interactions, and materials properties-electronic properties relationships are not necessarily applicable to GaAs (and to other semiconductor compounds). In many instances totally unexpected relationships were found to prevail.
NASA Technical Reports Server (NTRS)
Hofer, O. C.
1982-01-01
Closed cycle, CW waveform and short wavelength laser devices are desirable characteristics for laser propulsion. The choice of specific wavelengths for hydrogen fuel affects the operational conditions under which a laser supported absorption (LSA) wave is initiated and maintained. The mechanisms of initiating and maintaining LSA waves depend on the wavelength of the laser. Consequently, the shape and size of the hot core plasma is also dependent on wavelength and pressure. Detailed modeling of these mechanisms must be performed before their actual significance can be ascertained. Inverse bremsstrahlung absorption mechanism is the dominant mechanism for coupling energy into the plasma, but other mechanisms which are wavelength dependent can dictate the LSA wave plasma initiation and maintenance conditions. Multiphoton mechanisms become important at visible or shorter wavelengths. These are important mechanisms in creating the initial H2 gas breakdown and supplying the precursor electrons required to sustain the plasma.
Interface Prostheses With Classifier-Feedback-Based User Training.
Fang, Yinfeng; Zhou, Dalin; Li, Kairu; Liu, Honghai
2017-11-01
It is evident that user training significantly affects performance of pattern-recognition-based myoelectric prosthetic device control. Despite plausible classification accuracy on offline datasets, online accuracy usually suffers from the changes in physiological conditions and electrode displacement. The user ability in generating consistent electromyographic (EMG) patterns can be enhanced via proper user training strategies in order to improve online performance. This study proposes a clustering-feedback strategy that provides real-time feedback to users by means of a visualized online EMG signal input as well as the centroids of the training samples, whose dimensionality is reduced to minimal number by dimension reduction. Clustering feedback provides a criterion that guides users to adjust motion gestures and muscle contraction forces intentionally. The experiment results have demonstrated that hand motion recognition accuracy increases steadily along the progress of the clustering-feedback-based user training, while conventional classifier-feedback methods, i.e., label feedback, hardly achieve any improvement. The result concludes that the use of proper classifier feedback can accelerate the process of user training, and implies prosperous future for the amputees with limited or no experience in pattern-recognition-based prosthetic device manipulation.It is evident that user training significantly affects performance of pattern-recognition-based myoelectric prosthetic device control. Despite plausible classification accuracy on offline datasets, online accuracy usually suffers from the changes in physiological conditions and electrode displacement. The user ability in generating consistent electromyographic (EMG) patterns can be enhanced via proper user training strategies in order to improve online performance. This study proposes a clustering-feedback strategy that provides real-time feedback to users by means of a visualized online EMG signal input as well as the centroids of the training samples, whose dimensionality is reduced to minimal number by dimension reduction. Clustering feedback provides a criterion that guides users to adjust motion gestures and muscle contraction forces intentionally. The experiment results have demonstrated that hand motion recognition accuracy increases steadily along the progress of the clustering-feedback-based user training, while conventional classifier-feedback methods, i.e., label feedback, hardly achieve any improvement. The result concludes that the use of proper classifier feedback can accelerate the process of user training, and implies prosperous future for the amputees with limited or no experience in pattern-recognition-based prosthetic device manipulation.
Numerical investigations of MRI RF field induced heating for external fixation devices
2013-01-01
Background The magnetic resonance imaging (MRI) radio frequency (RF) field induced heating on external fixation devices can be very high in the vicinity of device screws. Such induced RF heating is related to device constructs, device placements, as well as the device insertion depth into human subjects. In this study, computational modeling is performed to determine factors associated with such induced heating. Methods Numerical modeling, based on the finite-difference time-domain (FDTD) method, is used to evaluate the temperature rises near external device screw tips inside the ASTM phantom for both 1.5-T and 3-T MRI systems. The modeling approach consists of 1) the development of RF coils for 1.5-T and 3-T, 2) the electromagnetic simulations of energy deposition near the screw tips of external fixation devices, and 3) the thermal simulations of temperature rises near the tips of these devices. Results It is found that changing insertion depth and screw spacing could largely affect the heating of these devices. In 1.5-T MRI system, smaller insertion depth and larger pin spacing will lead to higher temperature rise. However, for 3-T MRI system, the relation is not very clear when insertion depth is larger than 5 cm or when pin spacing became larger than 20 cm. The effect of connection bar material on device heating is also studied and the heating mechanism of the device is analysed. Conclusions Numerical simulation is used to study RF heating for external fixation devices in both 1.5-T and 3-T MRI coils. Typically, shallower insertion depth and larger pin spacing with conductive bar lead to higher RF heating. The heating mechanism is explained using induced current along the device and power decay inside ASTM phantom. PMID:23394173
Ceriotti, Ferruccio; Kaczmarek, Ewa; Guerra, Elena; Mastrantonio, Fabrizio; Lucarelli, Fausto; Valgimigli, Francesco; Mosca, Andrea
2015-03-01
Point-of-care (POC) testing devices for monitoring glucose and ketones can play a key role in the management of dysglycemia in hospitalized diabetes patients. The accuracy of glucose devices can be influenced by biochemical changes that commonly occur in critically ill hospital patients and by the medication prescribed. Little is known about the influence of these factors on ketone POC measurements. The aim of this study was to assess the analytical performance of POC hospital whole-blood glucose and ketone meters and the extent of glucose interference factors on the design and accuracy of ketone results. StatStrip glucose/ketone, Optium FreeStyle glucose/ketone, and Accu-Chek Performa glucose were also assessed and results compared to a central laboratory reference method. The analytical evaluation was performed according to Clinical and Laboratory Standards Institute (CLSI) protocols for precision, linearity, method comparison, and interference. The interferences assessed included acetoacetate, acetaminophen, ascorbic acid, galactose, maltose, uric acid, and sodium. The accuracies of both Optium ketone and glucose measurements were significantly influenced by varying levels of hematocrit and ascorbic acid. StatStrip ketone and glucose measurements were unaffected by the interferences tested with exception of ascorbic acid, which reduced the higher level ketone value. The accuracy of Accu-Chek glucose measurements was affected by hematocrit, by ascorbic acid, and significantly by galactose. The method correlation assessment indicated differences between the meters in compliance to ISO 15197 and CLSI 12-A3 performance criteria. Combined POC glucose/ketone methods are now available. The use of these devices in a hospital setting requires careful consideration with regard to the selection of instruments not sensitive to hematocrit variation and presence of interfering substances. © 2014 Diabetes Technology Society.
Utilization of penile prosthesis and male incontinence prosthetics in Saudi Arabia.
Alwaal, Amjad; Al-Sayyad, Ahmad J
2017-01-01
Erectile dysfunction is a prevalent disease affecting over 50% of men between the ages of 40 and 70 years. Penile prosthesis represents the end of the line treatment when other less invasive therapies fail or are contraindicated. Male stress urinary incontinence can significantly diminish quality of life and lead to embarrassment and social withdrawal. Surgical therapies, such as male urethral slings and artificial urinary sphincters (AUS), are considered effective and safe treatments for male stress incontinence. No data exist on the utilization of penile prosthesis or male incontinence surgical treatment in Saudi Arabia. Generally, urological prosthetic surgery is performed either in private hospitals or in government hospitals. Our aim was to assess the trend of penile prosthesis and male incontinence device utilization in Saudi Arabia. We utilized sales' data of penile prosthetics, male slings, and AUS from the only two companies selling these devices in Saudi Arabia (AMS ® and Coloplast ® ), from January 2013 to December 2016. There were 2599 penile prosthesis implantation procedures done in the study period, with 67% of them performed in private institutions. There was a progressively increased use of penile prosthetics which nearly doubled from 2013 to 2016. The main type of prosthesis utilized was the semirigid type 70% versus 11% of the 2-piece inflatable and 17% of the 3-piece inflatable device. Only 10 slings and 31 AUS were inserted during the same study period. There is an increased utilization of penile prosthetics in Saudi Arabia. The private sector performs the majority of penile prosthesis procedures, and most of them are of the semirigid type. The governmental sector is more likely to perform inflatable penile prosthesis and male incontinence device procedures. Male incontinence prosthetics' use is very limited in Saudi Arabia.
Harada, Mikio; Takahara, Masatoshi; Maruyama, Masahiro; Nemoto, Tadanobu; Koseki, Kazuhiko; Kato, Yoshihiro
2014-04-01
Valgus instability was reported to be higher with the elbow in 60° of flexion, rather than in 30° of flexion, although there are no studies using valgus stress radiography by gravity (gravity radiography) with the elbow in 60° of flexion. Fifty-seven patients with medial elbow pain participated. For both elbows, valgus stress radiography by use of a Telos device (Telos radiography) and gravity radiography, with the elbow in 60° of flexion, were performed for the assessment of medial elbow laxity. In both radiographs, the medial elbow joint space (MJS) on the affected side was compared with that on the opposite side, and the increase in the MJS on the affected side was assessed. For the Telos radiographs, the mean MJS was 4.7 mm on the affected side and 4.0 mm on the opposite side, with the mean increase in the MJS on the affected side being 0.7 mm. For the gravity radiographs, the mean MJS was 5.0 mm on the affected side and 4.2 mm on the opposite side, with the mean increase in the MJS on the affected side being 0.8 mm. There were significant correlations between the Telos and gravity radiographs in the MJS on the affected side, the MJS on the opposite side, and the increase in the MJS on the affected side (respectively, P < .0001). There was also a high level of intraobserver and interobserver reliability for the assessment of the gravity radiographs. Gravity radiography is useful for assessment of medial elbow laxity, similar to Telos radiography. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
ERIC Educational Resources Information Center
Bing, Mark N.; Stewart, Susan M.; Davison, H. Kristl
2009-01-01
Handheld calculators have been used on the job for more than 30 years, yet the degree to which these devices can affect performance on employment tests of mathematical ability has not been thoroughly examined. This study used a within-subjects research design (N = 167) to investigate the effects of calculator use on test score reliability, test…
Buttini, Francesca; Pasquali, Irene; Brambilla, Gaetano; Copelli, Diego; Alberi, Massimiliano Dagli; Balducci, Anna Giulia; Bettini, Ruggero; Sisti, Viviana
2016-03-01
The aim of this work was to evaluate the effect of two different dry powder inhalers, of the NGI induction port and Alberta throat and of the actual inspiratory profiles of asthmatic patients on in-vitro drug inhalation performances. The two devices considered were a reservoir multidose and a capsule-based inhaler. The formulation used to test the inhalers was a combination of formoterol fumarate and beclomethasone dipropionate. A breath simulator was used to mimic inhalatory patterns previously determined in vivo. A multivariate approach was adopted to estimate the significance of the effect of the investigated variables in the explored domain. Breath simulator was a useful tool to mimic in vitro the in vivo inspiratory profiles of asthmatic patients. The type of throat coupled with the impactor did not affect the aerodynamic distribution of the investigated formulation. However, the type of inhaler and inspiratory profiles affected the respirable dose of drugs. The multivariate statistical approach demonstrated that the multidose inhaler, released efficiently a high fine particle mass independently from the inspiratory profiles adopted. Differently, the single dose capsule inhaler, showed a significant decrease of fine particle mass of both drugs when the device was activated using the minimum inspiratory volume (592 mL).
Integrated micro thermoelectric cooler: Theory, fabrication and characterization
NASA Astrophysics Data System (ADS)
da Silva, Luciana Wasnievski
The flows of heat and electricity in a column-type micro thermoelectric (TE) cooler that uses telluride compounds for the n- and p-type elements, are analyzed by modeling the various interfacial resistances. Electron (barrier tunneling) and phonon (diffuse mismatch) boundary resistances at the TE/metal interface, and thermal non-equilibrium between electrons and phonons adjacent to this interface (cooling length), increase the thermal conduction resistance and decrease the Seebeck coefficient of the TE elements. These in turn reduce the device cooling performance, which is also affected by the thermal and electrical contact resistances at the TE/metal and the metal/electrical-insulator interfaces. From the device optimization, it is predicted (for an available voltage of 3 V) that a micro TE cooler with 50 TE pairs (Bi2Te3 and Sb2Te3 high performance TE films), column thickness of 4 mum (limited by the current fabrication process), and column cross-section area of 7 mum x 7 mum, should produce a temperature drop of 10 K with a cooling load of 10 mW. This device will operate with a current of 11 mA and will require a power of 34 mW. The coefficient of performance is 0.3. Co-evaporated Bi-Te and Sb-Te films were fabricated at various deposition conditions (evaporation rate of individual species and substrate temperature), and their TE properties (Seebeck coefficient, electrical resistivity, and carrier concentration) were measured, in search of optimal TE performance. The deposition rates were controlled such that the tellurium atomic composition changed from 48 to 74%, and the substrate temperature ranged from 130 to 300°C. The chemical composition and crystal structure of the films were recorded (using a microprobe and a X-ray diffractomer, respectively), analyzed, and compared with standard Bi2Te3 and Sb2Te 3 single crystal samples. High performance TE films had a tellurium atomic concentration around 60% and were deposited at a substrate temperature between 260 and 270°C. Due to degradation of the photoresist used for patterning the TE films, in the first-generation device, they were deposited with a maximum substrate temperature of 130°C. The TE columns were connected using Cr/Au/Ti/Pt layers at the hot junctions, and Cr/Au layers at the cold junctions. A device with 60 TE pairs and column width of 40 mum (finer device structures had limited yield) was tested using infrared thermometry. The average cooling achieved was about 1 K, which was close to the predicted value. A future-generation device is proposed, where high performance TE films can be patterned with optimized geometries (high density micro TE coolers), allowing these devices to fulfill the requirements for a wireless environmental monitor application.
Varley, J. B.; Conway, A. M.; Voss, L. F.; ...
2015-02-09
Thallium bromide (TlBr) crystals subjected to hydrochloric acid (HCl) chemical treatments have been shown to advantageously affect device performance and longevity in TlBr-based room temperature radiation detectors, yet the exact mechanisms of the improvements remain poorly understood. Here in this paper, we investigate the influence of several HCl chemical treatments on device-grade TlBr and describe the changes in the composition and electronic structure of the surface. Composition analysis and depth profiles obtained from secondary ion mass spectrometry (SIMS) identify the extent to which each HCl etch condition affects the detector surface region and forms of a graded TlBr/TlBr 1-xCL xmore » surface heterojunction. Using a combination of X-ray photoemission spectroscopy (XPS) and hybrid density functional calculations, we are able to determine the valence band offsets, band gaps, and conduction band offsets as a function of Cl content over the entire composition range of TIBr 1-xC1 X. This study establishes a strong correlation between device process conditions, surface chemistry, and electronic structure with the goal of further optimizing the long-term stability and radiation response of TlBr-based detectors.« less
Nerenz, Robert D; Song, Haowei; Gronowski, Ann M
2014-04-01
The predominant hCG variant in urine, hCG β core fragment (hCGβcf), has been demonstrated to cause false-negative results in qualitative point-of-care (POC) hCG devices. This is a major concern for healthcare professionals using POC pregnancy tests. We developed a screening method to evaluate qualitative POC hCG devices for their susceptibility to inhibition by hCGβcf. Using this method, we evaluated the performance of 11 commonly used devices. A wide range of purified hCG and hCGβcf concentrations were mixed and tested on 2 POC devices. By use of those results, a screening method was defined and 9 additional POC devices were evaluated. Two solutions containing (a) 500 pmol/L (171 IU/L) intact hCG with 0 pmol/L hCGβcf and (b) 500 pmol/L intact hCG with 500 000 pmol/L hCGβcf were used to screen all POC devices. The OSOM and Cen-Med Elite devices were found to be most susceptible to false-negative results due to hCGβcf. The BC Icon 20 and the Alere were the least susceptible. The remaining 7 were moderately affected. Devices that gave the strongest signal with hCGβcf alone were those that were least likely to show a hook effect. The screening method put forth here can be used by device users and manufacturers to evaluate POC devices for inhibition by hCGβcf. Of 11 devices evaluated, only 2 have been identified that exhibit minimal to no susceptibility to hCGβcf.
Positive current collector for Li||Sb-Pb liquid metal battery
NASA Astrophysics Data System (ADS)
Ouchi, Takanari; Sadoway, Donald R.
2017-07-01
Corrosion in grid-scale energy storage devices adversely affects service lifetime and thus has a significant economic impact on their deployment. In this work, we investigate the corrosion of steel and stainless steels (SSs) as positive current collectors in the Li||Sb-Pb liquid metal battery. The erosion and formation of new phases on low-carbon steel, SS301, and SS430 were evaluated both in static conditions and under cell operating conditions. The cell performance is not adversely affected by the dissolution of iron or chromium but rather nickel. Furthermore, the in situ formation of a Fe-Cr-Sb layer helps mitigate the recession of SS430.
Yang, Mengjin; Zhang, Taiyang; Schulz, Philip; Li, Zhen; Li, Ge; Kim, Dong Hoe; Guo, Nanjie; Berry, Joseph J.; Zhu, Kai; Zhao, Yixin
2016-01-01
Organometallic halide perovskite solar cells (PSCs) have shown great promise as a low-cost, high-efficiency photovoltaic technology. Structural and electro-optical properties of the perovskite absorber layer are most critical to device operation characteristics. Here we present a facile fabrication of high-efficiency PSCs based on compact, large-grain, pinhole-free CH3NH3PbI3−xBrx (MAPbI3−xBrx) thin films with high reproducibility. A simple methylammonium bromide (MABr) treatment via spin-coating with a proper MABr concentration converts MAPbI3 thin films with different initial film qualities (for example, grain size and pinholes) to high-quality MAPbI3−xBrx thin films following an Ostwald ripening process, which is strongly affected by MABr concentration and is ineffective when replacing MABr with methylammonium iodide. A higher MABr concentration enhances I–Br anion exchange reaction, yielding poorer device performance. This MABr-selective Ostwald ripening process improves cell efficiency but also enhances device stability and thus represents a simple, promising strategy for further improving PSC performance with higher reproducibility and reliability. PMID:27477212
Krueger, Wesley W O
2011-01-01
An eyewear mounted visual display ("User-worn see-through display") projecting an artificial horizon aligned with the user's head and body position in space can prevent or lessen motion sickness in susceptible individuals when in a motion provocative environment as well as aid patients undergoing vestibular rehabilitation. In this project, a wearable display device, including software technology and hardware, was developed and a phase I feasibility study and phase II clinical trial for safety and efficacy were performed. Both phase I and phase II were prospective studies funded by the NIH. The phase II study used repeated measures for motion intolerant subjects and a randomized control group (display device/no display device) pre-posttest design for patients in vestibular rehabilitation. Following technology and display device development, 75 patients were evaluated by test and rating scales in the phase II study; 25 subjects with motion intolerance used the technology in the display device in provocative environments and completed subjective rating scales, whereas 50 patients were evaluated before and after vestibular rehabilitation (25 using the display device and 25 in a control group) using established test measures. All patients with motion intolerance rated the technology as helpful for nine symptoms assessed, and 96% rated the display device as simple and easy to use. Duration of symptoms significantly decreased with use of the technology displayed. In patients undergoing vestibular rehabilitation, there were no significant differences in amount of change from pre- to posttherapy on objective balance tests between display device users and controls. However, those using the technology required significantly fewer rehabilitation sessions to achieve those outcomes than the control group. A user-worn see-through display, utilizing a visual fixation target coupled with a stable artificial horizon and aligned with user movement, has demonstrated substantial benefit for individuals susceptible to motion intolerance and spatial disorientation and those undergoing vestibular rehabilitation. The technology developed has applications in any environment where motion sensitivity affects human performance.
Photodamage and the importance of photoprotection in biomolecular-powered device applications.
Vandelinder, Virginia; Bachand, George D
2014-01-07
In recent years, an enhanced understanding of the mechanisms underlying photobleaching and photoblinking of fluorescent dyes has led to improved photoprotection strategies, such as reducing and oxidizing systems (ROXS) that reduce blinking and oxygen scavenging systems to reduce bleaching. Excitation of fluorescent dyes can also result in damage to catalytic proteins (e.g., biomolecular motors), affecting the performance of integrated devices. Here, we characterized the motility of microtubules driven by kinesin motor proteins using various photoprotection strategies, including a microfluidic deoxygenation device. Impaired motility of microtubules was observed at high excitation intensities in the absence of photoprotection as well as in the presence of an enzymatic oxygen scavenging system. In contrast, using a polydimethylsiloxane (PDMS) microfluidic deoxygenation device and ROXS, not only were the fluorophores slower to bleach but also moving the velocity and fraction of microtubules over time remained unaffected even at high excitation intensities. Further, we demonstrate the importance of photoprotection by examining the effect of photodamage on the behavior of a switchable mutant of kinesin. Overall, these results demonstrate that improved photoprotection strategies may have a profound impact on functional fluorescently labeled biomolecules in integrated devices.
Thaler, Lore; Castillo-Serrano, Josefina
2016-01-01
Echolocation is the ability to use reflected sound to obtain information about the spatial environment. Echolocation is an active process that requires both the production of the emission as well as the sensory processing of the resultant sound. Appreciating the general usefulness of echo-acoustic cues for people, in particular those with vision impairments, various devices have been built that exploit the principle of echolocation to obtain and provide information about the environment. It is common to all these devices that they do not require the person to make a sound. Instead, the device produces the emission autonomously and feeds a resultant sound back to the user. Here we tested if echolocation performance in a simple object detection task was affected by the use of a head-mounted loudspeaker as compared to active clicking. We found that 27 sighted participants new to echolocation did generally better when they used a loudspeaker as compared to mouth-clicks, and that two blind participants with experience in echolocation did equally well with mouth clicks and the speaker. Importantly, performance of sighted participants' was not statistically different from performance of blind experts when they used the speaker. Based on acoustic click data collected from a subset of our participants, those participants whose mouth clicks were more similar to the speaker clicks, and thus had higher peak frequencies and sound intensity, did better. We conclude that our results are encouraging for the consideration and development of assistive devices that exploit the principle of echolocation.
Thaler, Lore; Castillo-Serrano, Josefina
2016-01-01
Echolocation is the ability to use reflected sound to obtain information about the spatial environment. Echolocation is an active process that requires both the production of the emission as well as the sensory processing of the resultant sound. Appreciating the general usefulness of echo-acoustic cues for people, in particular those with vision impairments, various devices have been built that exploit the principle of echolocation to obtain and provide information about the environment. It is common to all these devices that they do not require the person to make a sound. Instead, the device produces the emission autonomously and feeds a resultant sound back to the user. Here we tested if echolocation performance in a simple object detection task was affected by the use of a head-mounted loudspeaker as compared to active clicking. We found that 27 sighted participants new to echolocation did generally better when they used a loudspeaker as compared to mouth-clicks, and that two blind participants with experience in echolocation did equally well with mouth clicks and the speaker. Importantly, performance of sighted participants’ was not statistically different from performance of blind experts when they used the speaker. Based on acoustic click data collected from a subset of our participants, those participants whose mouth clicks were more similar to the speaker clicks, and thus had higher peak frequencies and sound intensity, did better. We conclude that our results are encouraging for the consideration and development of assistive devices that exploit the principle of echolocation. PMID:27135407
Ortenzi, Monica; Ghiselli, Roberto; Baldarelli, Maddalena; Cardinali, Luca; Guerrieri, Mario
2018-04-01
The latest robotic bipolar vessel sealing tools have been described to be effective allowing to perform procedures with reduced blood loss and shorter operative times. The aim of this study was to assess the efficacy and reliability of these devices applied in different robotic procedures. All robotic operations, between 2014 and 2016, were performed using the EndoWrist One VesselSealer (EWO, Intuitive Surgical, Sunnyvale, CA), a bipolar fully wristed device. Data, including age, gender, body mass index (BMI), were collected. Robot docking time, intraoperative blood loss, robot malfunctioning and overall operative time were analyzed. A meta-analysis of the literature was carried out to point the attention to three different parameters (mean blood loss, operating time and hospital stay) trying to identify how different coagulation devices may affect them. In 73 robotic procedures, the mean operative time was 118.2 minutes (75-125 minutes). Mean hospital stay was four days (2-10 days). There were two post-operative complications (2.74%). The bipolar vessel sealer offers the efficacy of bipolar diathermy and the advantages of a fully wristed instrument. It does not require any change of instruments for coagulation or involvement of the bedside assistant surgeon. These characteristics lead to a reduction in operative time.
Current topics in surgery for multiple ventricular septal defects.
Yoshimura, Naoki; Fukahara, Kazuaki; Yamashita, Akio; Doki, Yoshinori; Takeuchi, Katsunori; Higuma, Tomonori; Senda, Kazutaka; Toge, Masayoshi; Matsuo, Tatsuro; Nagura, Saori; Aoki, Masaya; Sakata, Kimimasa; Sakai, Mari
2016-04-01
In this review article, we describe several topics, including the sandwich technique, the transatrial re-endocardialization technique, the limited apical left ventriculotomy approach and device closure. The sandwich technique was introduced for the closure of muscular ventricular septal defects (VSD) by sandwiching the septum between two felt patches placed in the left and right ventricle. This technique requires neither the transection of muscular trabeculae nor ventriculotomy. Although the sandwich technique has resulted in the improvement of surgical outcomes, cases of postoperative cardiac dysfunction have been reported. Multiple smaller VSDs have been closed with transatrial re-endocardialization. Septal dysfunction may be avoided through this technique, in which the septal trabeculae are approximated in two layers of superficial, endocardial running sutures. Recently, a number of reports have recommended a limited apical left ventriculotomy approach. With this technique, a much shorter incision of around 1 cm at the apex of the left ventricle may be sufficient for achieving the complete closure of apical muscular VSDs. The transcatheter or perventricular device closure of muscular VSDs has increasingly been performed with good results. Although favorable early and mid-term results of device closure have been reported, this method is not always safer or less invasive than surgical closure. Long-term evaluations should be performed to determine whether the right and left ventricular functions are affected by treatment with relatively large devices in the heart.
Smoking Through a Topography Device Diminishes Some of the Acute Rewarding Effects of Smoking.
Ross, Kathryn C; Juliano, Laura M
2016-05-01
Smoking topography (ST) devices are an important methodological tool for quantifying puffing behavior (eg, puff volume, puff velocity) as well as identifying puffing differences across individuals and situations. Available ST devices are designed such that the smoker's mouth and hands have direct contact with the device rather than the cigarette itself. Given the importance of the sensorimotor aspects of cigarette smoking in smoking reward, it is possible that ST devices may interfere with the acute rewarding effects of smoking. Despite the methodological importance of this issue, few studies have directly compared subjective reactions to smoking through a topography device to naturalistic smoking. Smokers (N = 58; 38% female) smoked their preferred brand of cigarettes one time through a portable topography device and one time naturalistically, in counterbalanced order across two laboratory sessions. Smoking behavior (eg, number of puffs) and subjective effects (eg, urge reduction, affect, smoking satisfaction) were assessed. Negative affect reduction was greater in the natural smoking condition relative to the topography condition, but differences were not significant on measures of urge, withdrawal, or positive affect. Self-reported smoking satisfaction, enjoyment of respiratory tract sensations, psychological reward, craving reduction, and other rewarding effects of smoking were also significantly greater in the naturalistic smoking condition. The effects of using a ST device on the smoking experience should be considered when it is used in research as it may diminish some of the rewarding effects of smoking. When considering the inclusion of a smoking topography device in one's research, it is important to know if use of that device will alter the smoker's experience. This study assessed affective and subjective reactions to smoking through a topography device compared to naturalistic smoking. We found that smoking satisfaction, psychological reward, enjoyment of respiratory tract sensations and other rewarding effects were all diminished when smoking through the topography device. The effects of using a smoking topography device on the smoking experience should be considered when it is used in future research. © The Author 2015. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Smoking Through a Topography Device Diminishes Some of the Acute Rewarding Effects of Smoking
Juliano, Laura M.
2016-01-01
Abstract Background: Smoking topography (ST) devices are an important methodological tool for quantifying puffing behavior (eg, puff volume, puff velocity) as well as identifying puffing differences across individuals and situations. Available ST devices are designed such that the smoker’s mouth and hands have direct contact with the device rather than the cigarette itself. Given the importance of the sensorimotor aspects of cigarette smoking in smoking reward, it is possible that ST devices may interfere with the acute rewarding effects of smoking. Despite the methodological importance of this issue, few studies have directly compared subjective reactions to smoking through a topography device to naturalistic smoking. Methods: Smokers ( N = 58; 38% female) smoked their preferred brand of cigarettes one time through a portable topography device and one time naturalistically, in counterbalanced order across two laboratory sessions. Smoking behavior (eg, number of puffs) and subjective effects (eg, urge reduction, affect, smoking satisfaction) were assessed. Results: Negative affect reduction was greater in the natural smoking condition relative to the topography condition, but differences were not significant on measures of urge, withdrawal, or positive affect. Self-reported smoking satisfaction, enjoyment of respiratory tract sensations, psychological reward, craving reduction, and other rewarding effects of smoking were also significantly greater in the naturalistic smoking condition. Conclusions: The effects of using a ST device on the smoking experience should be considered when it is used in research as it may diminish some of the rewarding effects of smoking. Implications: When considering the inclusion of a smoking topography device in one’s research, it is important to know if use of that device will alter the smoker’s experience. This study assessed affective and subjective reactions to smoking through a topography device compared to naturalistic smoking. We found that smoking satisfaction, psychological reward, enjoyment of respiratory tract sensations and other rewarding effects were all diminished when smoking through the topography device. The effects of using a smoking topography device on the smoking experience should be considered when it is used in future research. PMID:26209851
NASA Astrophysics Data System (ADS)
Latzel, M.; Büttner, P.; Sarau, G.; Höflich, K.; Heilmann, M.; Chen, W.; Wen, X.; Conibeer, G.; Christiansen, S. H.
2017-02-01
Nanotextured surfaces provide an ideal platform for efficiently capturing and emitting light. However, the increased surface area in combination with surface defects induced by nanostructuring e.g. using reactive ion etching (RIE) negatively affects the device’s active region and, thus, drastically decreases device performance. In this work, the influence of structural defects and surface states on the optical and electrical performance of InGaN/GaN nanorod (NR) light emitting diodes (LEDs) fabricated by top-down RIE of c-plane GaN with InGaN quantum wells was investigated. After proper surface treatment a significantly improved device performance could be shown. Therefore, wet chemical removal of damaged material in KOH solution followed by atomic layer deposition of only 10 {nm} alumina as wide bandgap oxide for passivation were successfully applied. Raman spectroscopy revealed that the initially compressively strained InGaN/GaN LED layer stack turned into a virtually completely relaxed GaN and partially relaxed InGaN combination after RIE etching of NRs. Time-correlated single photon counting provides evidence that both treatments—chemical etching and alumina deposition—reduce the number of pathways for non-radiative recombination. Steady-state photoluminescence revealed that the luminescent performance of the NR LEDs is increased by about 50% after KOH and 80% after additional alumina passivation. Finally, complete NR LED devices with a suspended graphene contact were fabricated, for which the effectiveness of the alumina passivation was successfully demonstrated by electroluminescence measurements.
ARM-based visual processing system for prosthetic vision.
Matteucci, Paul B; Byrnes-Preston, Philip; Chen, Spencer C; Lovell, Nigel H; Suaning, Gregg J
2011-01-01
A growing number of prosthetic devices have been shown to provide visual perception to the profoundly blind through electrical neural stimulation. These first-generation devices offer promising outcomes to those affected by degenerative disorders such as retinitis pigmentosa. Although prosthetic approaches vary in their placement of the stimulating array (visual cortex, optic-nerve, epi-retinal surface, sub-retinal surface, supra-choroidal space, etc.), most of the solutions incorporate an externally-worn device to acquire and process video to provide the implant with instructions on how to deliver electrical stimulation to the patient, in order to elicit phosphenized vision. With the significant increase in availability and performance of low power-consumption smart phone and personal device processors, the authors investigated the use of a commercially available ARM (Advanced RISC Machine) device as an externally-worn processing unit for a prosthetic neural stimulator for the retina. A 400 MHz Samsung S3C2440A ARM920T single-board computer was programmed to extract 98 values from a 1.3 Megapixel OV9650 CMOS camera using impulse, regional averaging and Gaussian sampling algorithms. Power consumption and speed of video processing were compared to results obtained to similar reported devices. The results show that by using code optimization, the system is capable of driving a 98 channel implantable device for the restoration of visual percepts to the blind.
Safety of capsule endoscopy using human body communication in patients with cardiac devices.
Chung, Joo Won; Hwang, Hye Jin; Chung, Moon Jae; Park, Jeong Youp; Pak, Hui-Nam; Song, Si Young
2012-06-01
The MiroCam (IntroMedic, Ltd., Seoul, Korea) is a small-bowel capsule endoscope that uses human body communication to transmit data. The potential interactions between cardiac devices and the capsule endoscope are causes for concern, but no data are available for this matter. This clinical study was designed to evaluate the potential influence of the MiroCam capsules on cardiac devices. Patients with cardiac pacemakers or implantable cardiac defibrillators referred for evaluation of small bowel disease were prospectively enrolled in this study. Before capsule endoscopy, a cardiologist checked baseline electrocardiograms and functions of the cardiac devices. Cardiac rhythms were continuously monitored by 24-h telemetry during capsule endoscopy in the hospital. After completion of procedures, functions of the cardiac devices were checked again for interference. Images from the capsule endoscopy were reviewed and analyzed for technical problems. Six patients, three with pacemakers and three with implantable cardiac defibrillators, were included in the study. We identified no disturbances in the cardiac devices and no arrhythmias detected on telemetry monitoring during capsule endoscopy. No significant changes in the programmed parameters of the cardiac devices were noted after capsule endoscopy. There were no imaging disturbances from the cardiac devices on capsule endoscopy. Capsule endoscopy using human body communication to transmit data was safely performed in patients with cardiac pacemakers or implantable cardiac defibrillators. Images from the capsule endoscopy were not affected by cardiac devices. A further large-scale study is required to confirm the safety of capsule endoscopy with various types of cardiac devices.
Simulating ideal assistive devices to reduce the metabolic cost of walking with heavy loads.
Dembia, Christopher L; Silder, Amy; Uchida, Thomas K; Hicks, Jennifer L; Delp, Scott L
2017-01-01
Wearable robotic devices can restore and enhance mobility. There is growing interest in designing devices that reduce the metabolic cost of walking; however, designers lack guidelines for which joints to assist and when to provide the assistance. To help address this problem, we used musculoskeletal simulation to predict how hypothetical devices affect muscle activity and metabolic cost when walking with heavy loads. We explored 7 massless devices, each providing unrestricted torque at one degree of freedom in one direction (hip abduction, hip flexion, hip extension, knee flexion, knee extension, ankle plantarflexion, or ankle dorsiflexion). We used the Computed Muscle Control algorithm in OpenSim to find device torque profiles that minimized the sum of squared muscle activations while tracking measured kinematics of loaded walking without assistance. We then examined the metabolic savings provided by each device, the corresponding device torque profiles, and the resulting changes in muscle activity. We found that the hip flexion, knee flexion, and hip abduction devices provided greater metabolic savings than the ankle plantarflexion device. The hip abduction device had the greatest ratio of metabolic savings to peak instantaneous positive device power, suggesting that frontal-plane hip assistance may be an efficient way to reduce metabolic cost. Overall, the device torque profiles generally differed from the corresponding net joint moment generated by muscles without assistance, and occasionally exceeded the net joint moment to reduce muscle activity at other degrees of freedom. Many devices affected the activity of muscles elsewhere in the limb; for example, the hip flexion device affected muscles that span the ankle joint. Our results may help experimentalists decide which joint motions to target when building devices and can provide intuition for how devices may interact with the musculoskeletal system. The simulations are freely available online, allowing others to reproduce and extend our work.
Simulating ideal assistive devices to reduce the metabolic cost of walking with heavy loads
Silder, Amy; Uchida, Thomas K.; Hicks, Jennifer L.; Delp, Scott L.
2017-01-01
Wearable robotic devices can restore and enhance mobility. There is growing interest in designing devices that reduce the metabolic cost of walking; however, designers lack guidelines for which joints to assist and when to provide the assistance. To help address this problem, we used musculoskeletal simulation to predict how hypothetical devices affect muscle activity and metabolic cost when walking with heavy loads. We explored 7 massless devices, each providing unrestricted torque at one degree of freedom in one direction (hip abduction, hip flexion, hip extension, knee flexion, knee extension, ankle plantarflexion, or ankle dorsiflexion). We used the Computed Muscle Control algorithm in OpenSim to find device torque profiles that minimized the sum of squared muscle activations while tracking measured kinematics of loaded walking without assistance. We then examined the metabolic savings provided by each device, the corresponding device torque profiles, and the resulting changes in muscle activity. We found that the hip flexion, knee flexion, and hip abduction devices provided greater metabolic savings than the ankle plantarflexion device. The hip abduction device had the greatest ratio of metabolic savings to peak instantaneous positive device power, suggesting that frontal-plane hip assistance may be an efficient way to reduce metabolic cost. Overall, the device torque profiles generally differed from the corresponding net joint moment generated by muscles without assistance, and occasionally exceeded the net joint moment to reduce muscle activity at other degrees of freedom. Many devices affected the activity of muscles elsewhere in the limb; for example, the hip flexion device affected muscles that span the ankle joint. Our results may help experimentalists decide which joint motions to target when building devices and can provide intuition for how devices may interact with the musculoskeletal system. The simulations are freely available online, allowing others to reproduce and extend our work. PMID:28700630
Mizokuro, Toshiko; Tanigaki, Nobutaka; Miyadera, Tetsuhiko; Shibata, Yousei; Koganezawa, Tomoyuki
2018-04-01
The molecular orientation of π-conjugated molecules has been reported to significantly affect the performance of organic photovoltaic devices (OPVs) based on molecular films. Hence, the control of molecular orientation is a key issue toward the improvement of OPV performance. In this research, oriented thin films of an n-type molecule, 3,4,9,10-Perylenetetracarboxylic Bisbenzimida-zole (PTCBI), were formed by deposition on in-plane oriented polythiophene (PT) films. Orientation of the PTCBI films was evaluated by polarized UV-vis spectroscopy and 2D-Grazing incidence X-ray diffraction. Results indicated that PTCBI molecules on PT film exhibit nearly edge-on and in-plane orientation (with molecular long axis along the substrate), whereas PTCBI molecules without PT film exhibit neither. OPVs composed of PTCBI molecular film with and without PT were fabricated and evaluated for correlation of orientation with performance. The OPVs composed of PTCBI film with PT showed higher power conversion efficiency (PCE) than that of film without PT. The experiment indicated that in-plane orientation of PTCBI molecules absorbs incident light more efficiently, leading to increase in PCE.
Numerical investigation of performance of vane-type propellant management device by VOF methods
NASA Astrophysics Data System (ADS)
Liu, J. T.; Zhou, C.; Wu, Y. L.; Zhuang, B. T.; Li, Y.
2015-01-01
The orbital propellant management performance of the vane-type tank is so important for the propellant system and it determines the lifetime of the satellite. The propellant in the tank can be extruded by helium gas. To study the two phase distribution in the vane-type surface tension tank and the capability of the vane-type propellant management device (PMD), a large volume vane-type surface tension tank is analysed using 3-D unsteady numerical simulations. VOF methods are used to analyse the location of the interface of the two phase. Performances of the propellant acquisition vanes and propellant refillable reservoir in the tank are investigated. The flow conductivity of the propellant acquisition vanes and the liquid storage capacity of propellant refillable reservoir can be affected by the value of the gravity and the volume of the propellant in the tank. To avoid the large resistance causing by surface tension in an outflow of a small hole, the design of the vanes in a propellant refillable reservoir should have suitable space.
Implications of Weak-Link Behavior on the Performance of Mo/Au Bilayer Transition-Edge Sensors
NASA Technical Reports Server (NTRS)
Smith, Stephen J.
2011-01-01
Understanding the physical properties of the superconducting-to-normal transition is fundamental for optimizing the design and performance of transition-edge sensors (TESs). Recent critical current measurements of Mol Au bilayer test structures show that they act as weak superconducting links, exhibiting oscillatory, Fraunhofer-like behavior with applied magnetic field. In this paper we investigate the implications of this behavior for TES X-ray detectors, under operational bias conditions. These devices include normal metal features used for absorber attachment and unexplained noise suppression, which result in modifications to the previously reported critical current behavior. We present measurements of the logarithmic resistance sensitivity with temperature, a, and current, b, as a function of applied magnetic field and bias point within the resistive transition. Results show that these important device parameters exhibit similar oscillatory behavior with applied magnetic field, which in turn affects the signal responsivity and noise, and hence the energy resolution. These results show the significance of the critical current in determining the performance of TESs and hold promise to improve future.
Effect of p-GaN layer doping on the photoresponse of GaN-based p-i-n ultraviolet photodetectors
NASA Astrophysics Data System (ADS)
Wang, Jun; Guo, Jin; Xie, Feng; Wang, Wanjun; Wang, Guosheng; Wu, Haoran; Wang, Tanglin; Song, Man
2015-08-01
We report on two-dimensional (2D) numerical simulations of photoresponse characteristics for GaN based p-i-n ultraviolet (UV) photodetectors. Effects of doping density of p-GaN layer on the photoresponse have been investigated. In order to accurately simulate the device performance, the theoretical calculation includes doping-dependent mobility degradation by Arora model and high field saturation model. Theoretical modeling shows that the doping density of p- GaN layer can significantly affect the photoresponse of GaN based p-i-n UV photodetectors, especially at schottky contact. We have to make a suitable choice of the doping in the device design according to the simulation results.
High Stability Pentacene Transistors Using Polymeric Dielectric Surface Modifier.
Wang, Xiaohong; Lin, Guangqing; Li, Peng; Lv, Guoqiang; Qiu, Longzhen; Ding, Yunsheng
2015-08-01
1,6-bis(trichlorosilyl)hexane (C6Cl), polystyrene (PS), and cross-linked polystyrene (CPS) were investigated as gate dielectric modified layers for high performance organic transistors. The influence of the surface energy, roughness and morphology on the charge transport of the organic thin-film transistors (OTFTs) was investigated. The surface energy and roughness both affect the grain size of the pentacene films which will control the charge carrier mobility of the devices. Pentacene thin-film transistors fabricated on the CPS modified dielectric layers exhibited charge carrier mobility as high as 1.11 cm2 V-1 s-1. The bias stress stability for the CPS devices shows that the drain current only decays 1% after 1530 s and the mobility never decreases until 13530 s.
NASA Astrophysics Data System (ADS)
John, R.
The merits of the peening effect in improving the fatigue resistance of ferrous and non-ferrous media is discussed. The machines that perform the peening task are also discussed, including the rotating-wheel plant, pressure-type air-assisted peening machines, and suction systems. The peening process itself is discussed briefly, and an outline of the parameters that affect the product specification is presented. The merits of the Almen test strip as a measure of correct treatment are evaluated, and the two types of devices are discussed for monitoring the flow of peening media. The two types of feed control devices (one for ferrous media and the other for non-ferrous media) for accurately controlling the feed of peening media are also briefly examined.
Sharma, Alka; Srivastava, A K; Senguttuvan, T D; Husale, Sudhir
2017-12-20
Due to miniaturization of device dimensions, the next generation's photodetector based devices are expected to be fabricated from robust nanostructured materials. Hence there is an utmost requirement of investigating exotic optoelectronic properties of nanodevices fabricated from new novel materials and testing their performances at harsh conditions. The recent advances on 2D layered materials indicate exciting progress on broad spectral photodetection (BSP) but still there is a great demand for fabricating ultra-high performance photodetectors made from single material sensing broad electromagnetic spectrum since the detection range 325 nm-1550 nm is not covered by the conventional Si or InGaAs photodetectors. Alternatively, Bi 2 Te 3 is a layered material, possesses exciting optoelectronic, thermoelectric, plasmonics properties. Here we report robust photoconductivity measurements on Bi 2 Te 3 nanosheets and nanowires demonstrating BSP from UV to NIR. The nanosheets of Bi 2 Te 3 show the best ultra-high photoresponsivity (~74 A/W at 1550 nm). Further these nanosheets when transform into nanowires using harsh FIB milling conditions exhibit about one order enhancement in the photoresponsivity without affecting the performance of the device even after 4 months of storage at ambient conditions. An ultra-high photoresponsivity and BSP indicate exciting robust nature of topological insulator based nanodevices for optoelectronic applications.
Pillai, Krishna; Akhter, Javid; Chua, Terence C; Shehata, Mena; Alzahrani, Nayef; Al-Alem, Issan; Morris, David L
2015-03-01
Thermal ablation of liver tumors near large blood vessels is affected by the cooling effect of blood flow, leading to incomplete ablation. Hence, we conducted a comparative investigation of heat sink effect in monopolar (MP) and bipolar (BP) radiofrequency ablation (RFA), and microwave (MW) ablation devices.With a perfused calf liver, the ablative performances (volume, mass, density, dimensions), with and without heat sink, were measured. Heat sink was present when the ablative tip of the probes were 8.0 mm close to a major hepatic vein and absent when >30 mm away. Temperatures (T1 and T2) on either side of the hepatic vein near the tip of the probes, heating probe temperature (T3), outlet perfusate temperature (T4), and ablation time were monitored.With or without heat sink, BP radiofrequency ablated a larger volume and mass, compared with MP RFA or MW ablation, with latter device producing the highest density of tissue ablated. MW ablation produced an ellipsoidal shape while radiofrequency devices produced spheres.Percentage heat sink effect in Bipolar radiofrequency : Mono-polar radiofrequency : Microwave was (Volume) 33:41:22; (mass) 23:56:34; (density) 9.0:26:18; and (relative elipscity) 5.8:12.9:1.3, indicating that BP and MW devices were less affected.Percentage heat sink effect on time (minutes) to reach maximum temperature (W) = 13.28:9.2:29.8; time at maximum temperature (X) is 87:66:16.66; temperature difference (Y) between the thermal probes (T3) and the temperature (T1 + T2)/2 on either side of the hepatic vessel was 100:87:20; and temperature difference between the (T1 + T2)/2 and temperature of outlet circulating solution (T4), Z was 20.33:30.23:37.5.MW and BP radiofrequencies were less affected by heat sink while MP RFA was the most affected. With a single ablation, BP radiofrequency ablated a larger volume and mass regardless of heat sink.
Pillai, Krishna; Akhter, Javid; Chua, Terence C.; Shehata, Mena; Alzahrani, Nayef; Al-Alem, Issan; Morris, David L.
2015-01-01
Abstract Thermal ablation of liver tumors near large blood vessels is affected by the cooling effect of blood flow, leading to incomplete ablation. Hence, we conducted a comparative investigation of heat sink effect in monopolar (MP) and bipolar (BP) radiofrequency ablation (RFA), and microwave (MW) ablation devices. With a perfused calf liver, the ablative performances (volume, mass, density, dimensions), with and without heat sink, were measured. Heat sink was present when the ablative tip of the probes were 8.0 mm close to a major hepatic vein and absent when >30 mm away. Temperatures (T1 and T2) on either side of the hepatic vein near the tip of the probes, heating probe temperature (T3), outlet perfusate temperature (T4), and ablation time were monitored. With or without heat sink, BP radiofrequency ablated a larger volume and mass, compared with MP RFA or MW ablation, with latter device producing the highest density of tissue ablated. MW ablation produced an ellipsoidal shape while radiofrequency devices produced spheres. Percentage heat sink effect in Bipolar radiofrequency : Mono-polar radiofrequency : Microwave was (Volume) 33:41:22; (mass) 23:56:34; (density) 9.0:26:18; and (relative elipscity) 5.8:12.9:1.3, indicating that BP and MW devices were less affected. Percentage heat sink effect on time (minutes) to reach maximum temperature (W) = 13.28:9.2:29.8; time at maximum temperature (X) is 87:66:16.66; temperature difference (Y) between the thermal probes (T3) and the temperature (T1 + T2)/2 on either side of the hepatic vessel was 100:87:20; and temperature difference between the (T1 + T2)/2 and temperature of outlet circulating solution (T4), Z was 20.33:30.23:37.5. MW and BP radiofrequencies were less affected by heat sink while MP RFA was the most affected. With a single ablation, BP radiofrequency ablated a larger volume and mass regardless of heat sink. PMID:25738477
Aarts, M P J; Rosemann, A L P
2018-08-01
For treating affective disorders like SAD, light therapy is used although the underlying mechanism explaining this success remains unclear. To accelerate the research on defining the light characteristics responsible for inducing a specific effect a uniform manner for specifying the irradiance at the eye should be defined. This allows a genuine comparison between light-affect studies. An important factor impacting the irradiance at the eye are the radiant characteristics of the used light therapy device. In this study the radiant fluxes of five different light therapy devices were measured. The values were weighted against the spectral sensitivity of the five photopigments present in the human eye. A measurement was taken every five minutes to control for a potential stabilizing effect. The results show that all five devices show large differences in radiant flux. The devices equipped with blue LED lights have a much lower spectral radiant flux than the devices equipped with a fluorescent light source or a white LED. The devices with fluorescent lamps needed 30 min to stabilize to a constant radiant flux. In this study only five devices were measured. Radiant flux is just the first step to identify uniform specifications for light therapy devices. It is recommended to provide all five α-opic radiant fluxes. Preferably, the devices should come with a spectral power distribution of the radiant flux. For the devices equipped with a fluorescent lamp it is recommended to provide information on the stabilization time. Copyright © 2018 Elsevier B.V. All rights reserved.
Formally verifying human–automation interaction as part of a system model: limitations and tradeoffs
Bass, Ellen J.
2011-01-01
Both the human factors engineering (HFE) and formal methods communities are concerned with improving the design of safety-critical systems. This work discusses a modeling effort that leveraged methods from both fields to perform formal verification of human–automation interaction with a programmable device. This effort utilizes a system architecture composed of independent models of the human mission, human task behavior, human-device interface, device automation, and operational environment. The goals of this architecture were to allow HFE practitioners to perform formal verifications of realistic systems that depend on human–automation interaction in a reasonable amount of time using representative models, intuitive modeling constructs, and decoupled models of system components that could be easily changed to support multiple analyses. This framework was instantiated using a patient controlled analgesia pump in a two phased process where models in each phase were verified using a common set of specifications. The first phase focused on the mission, human-device interface, and device automation; and included a simple, unconstrained human task behavior model. The second phase replaced the unconstrained task model with one representing normative pump programming behavior. Because models produced in the first phase were too large for the model checker to verify, a number of model revisions were undertaken that affected the goals of the effort. While the use of human task behavior models in the second phase helped mitigate model complexity, verification time increased. Additional modeling tools and technological developments are necessary for model checking to become a more usable technique for HFE. PMID:21572930
Kumble, Sowmya; Zink, Elizabeth K; Burch, Mackenzie; Deluzio, Sandra; Stevens, Robert D; Bahouth, Mona N
2017-08-01
Recent trials have challenged the notion that very early mobility benefits patients with acute stroke. It is unclear how cerebral autoregulatory impairments, prevalent in this population, could be affected by mobilization. The safety of mobilizing patients who have external ventricular drainage (EVD) devices for cerebrospinal fluid diversion and intracranial pressure (ICP) monitoring is another concern due to risk of device dislodgment and potential elevation in ICP. We report hemodynamic and ICP responses during progressive, device-assisted mobility interventions performed in a critically ill patient with intracerebral hemorrhage (ICH) requiring two EVDs. A 55-year-old man was admitted to the Neuroscience Critical Care Unit with an acute thalamic ICH and complex intraventricular hemorrhage requiring placement of two EVDs. Progressive mobilization was achieved using mobility technology devices. Range of motion exercises were performed initially, progressing to supine cycle ergometry followed by incremental verticalization using a tilt table. Physiological parameters were recorded before and after the interventions. All mobility interventions were completed without any adverse event or clinically detectable change in the patient's neurological state. Physiological parameters including hemodynamic variables and ICP remained within prescribed goals throughout. Progressive, device-assisted early mobilization was feasible and safe in this critically ill patient with hemorrhagic stroke when titrated by an interdisciplinary team of skilled healthcare professionals. Studies are needed to gain insight into the hemodynamic and neurophysiological responses associated with early mobility in acute stroke to identify subsets of patients who are most likely to benefit from this intervention.
RF Exposure Analysis for Multiple Wi-Fi Devices In Enclosed Environment
NASA Technical Reports Server (NTRS)
Hwu, Shian U.; Rhodes, Bryan A.; deSilva, B. Kanishka; Sham, Catherine C.; Keiser, James R.
2013-01-01
Wi-Fi devices operated inside a metallic enclosure have been investigation in the recent years. A motivation for this study is to investigate wave propagation inside an enclosed environment such as elevator, car, aircraft, and spacecraft. There are performances and safety concerned that when the RF transmitters are used in the metallic enclosed environments. In this paper, the field distributions inside a confined room were investigated with multiple portable Wi-Fi devices. Computer simulations were performed using the rigorous computational electromagnetics (CEM). The method of moments (MoM) was used to model the mutual coupling among antennas. The geometrical theory of diffraction (GTD) was applied for the multiple reflections off the ground and walls. The prediction of the field distribution inside such environment is useful for the planning and deployment of a wireless radio and sensor system. Factors that affect the field strengths and distributions of radio waves in confined space were analyzed. The results could be used to evaluate the RF exposure safety in confined environment. By comparing the field distributions for various scenarios, it was observed that the Wi-Fi device counts, spacing and relative locations in the room are important factors in such environments. The RF Keep Out Zone (KOZ), where the electric field strengths exceed the permissible RF exposure limit, could be used to assess the RF human exposure compliance. As shown in this study, it s possible to maximize or minimize field intensity in specific area by arranging the Wi-Fi devices as a function of the relative location and spacing in a calculated manner.
2016-01-01
Background Online health education has expanded its reach due to cost-effective implementation and demonstrated effectiveness. However, a limitation exists with the evaluation of online health education implementations and how the impact of the system is attenuated by the extent to which a user engages with it. Moreover, the current online health education research does not consider how this engagement has been affected by the transition from fixed to mobile user access over the last decade. Objective This paper focuses on comparing the impact mobile versus fixed devices have on user engagement key performance indicators (KPI) associated with the wichealth website (.org), an Internet-based parent-child feeding intervention offered to clients associated with the US Department of Agriculture’s Special Supplemental Nutrition Program for Women, Infants, and Children (WIC). Methods Data were collected from 612,201 nutrition education lessons completed by 305,735 unique WIC participants in 21 states over a 1-year period. Data consisted of system-collected measures, profile items, and items from an exit survey administered at the conclusion of each lesson. User engagement was defined based on 3 KPIs associated with usage of the wichealth website: number of link views, link view time, and progression in stage of readiness to change. Independent samples t tests were used to compare KPIs between fixed only and mobile only device users and paired samples t tests were used to compare KPIs within users who completed at least one lesson each on both a fixed and mobile device. A logistic regression was performed to estimate the odds of KPI performance thresholds in the independent samples study group given access device type while controlling for confounding of user characteristics associated with these KPIs. Results Analysis of 8 user characteristics (lessons completed, race, ethnicity, language, state of residence, pregnancy status, beginning stage of change, and preferred nutrition education method) were significantly (P<.001) related to various KPI differences between mobile and fixed device access. Non-mobile users were significantly (P<.001) more likely to engage based on all 3 KPIs, even after logistic regression control for the potential confounding related to the strongly associated user characteristics identified. Conclusions The findings of this study support the idea that online health education developers need to seriously consider access device when creating programs. Online health education developers need to take extra effort to truly understand access patterns of populations being served, and whether or not access device will influence user engagement performance indicators. PMID:27847351
Characterization of Defects in Scaled Mis Dielectrics with Variable Frequency Charge Pumping
NASA Astrophysics Data System (ADS)
Paulsen, Ronald Eugene
1995-01-01
Historically, the interface trap has been extensively investigated to determine the effects on device performance. Recently, much attention has been paid to trapping in near-interface oxide traps. Performance of high precision analog circuitry is affected by charge trapping in near-interface oxide traps which produces hysteresis, charge redistribution errors, and dielectric relaxation effects. In addition, the performance of low power digital circuitry, with reduced noise margins, may be drastically affected by the threshold voltage shifts associated with charge trapping in near -interface oxide traps. Since near-interface oxide traps may substantially alter the performance of devices, complete characterization of these defects is necessary. In this dissertation a new characterization technique, variable frequency charge pumping, is introduced which allows charge trapped at the interface to be distinguished from the charge trapped within the oxide. The new experimental technique is an extension of the charge pumping technique to low frequencies such that tunneling may occur from interface traps to near-interface oxide traps. A generalized charge pumping model, based on Shockley-Read-Hall statistics and trap-to-trap tunneling theory, has been developed which allows a more complete characterization of near-interface oxide traps. A pair of coupled differential equations governing the rate of change of occupied interface and near-interface oxide traps have been developed. Due to the experimental conditions in the charge pumping technique the equations may be decoupled, leading to an equation governing the rate of change of occupied interface traps and an equation governing the rate of change of occcupied near-interface oxide traps. Solving the interface trap equation and applying non-steady state charge dynamics leads to an interface trap component of the charge pumping current. In addition, solution to the near-interface oxide trap equation leads to an additional oxide trap component to the charge pumping current. Numerical simulations have been performed to support the analytical development of the generalized charge pumping model. By varying the frequency of the applied charge pumping waveform and monitoring the charge recombined per cycle, the contributions from interface traps may be separated from the contributions of the near-interface oxide traps. The generalized charge pumping model allows characterization of the density and spatial distribution of near-interface oxide traps from this variable frequency charge pumping technique. Characterization of interface and near-interface oxide trap generation has been performed on devices exposed to ionizing radiation, hot electron injection, and high -field/Fowler-Nordheim stressing. Finally, using SONOS nonvolatile memory devices, a framework has been established for experimentally determining not only the spatial distribution of near-interface oxide traps, but also the energetic distribution. An experimental approach, based on tri-level charge pumping, is discussed which allows the energetic distribution of near-interface oxide traps to be determined.
NASA Astrophysics Data System (ADS)
Wang, Shuying; Huang, Xiaona; Sun, Haoxuan; Wu, Chunyang
2017-12-01
Inverted planar perovskite solar cells (PSCs), which are regarded as promising devices for new generation of photovoltaic systems, show many advantages, such as low-temperature film formation, low-cost fabrication, and smaller hysteresis compared with those of traditional n-i-p PSCs. As an important carrier transport layer in PSCs, the hole transport layer (HTL) considerably affects the device performance. Therefore, HTL modification becomes one of the most critical issues in improving the performance of PSCs. In this paper, we report an effective and environmentally friendly UV-ozone treatment method to enhance the hydrophilia of reduced graphene oxide (rGO) with its excellent electrical performance. The treated rGO was applied to doped poly(3,4-ethylenedioxythiophene) poly(styrene-sulfonate) (PEDOT:PSS) as HTL material of PSCs. Consequently, the performance of rGO/PEDOT:PSS-doped PSCs was improved significantly, with power conversion efficiency (PCE) of 10.7%, Jsc of 16.75 mA/cm2, Voc of 0.87 V, and FF of 75%. The PCE of this doped PSCs was 27% higher than that of the PSCs with pristine PEDOT:PSS as HTL. This performance was attributed to the excellent surface morphology and optimized hole mobility of the solution-processable rGO-modified PEDOT:PSS.
Raabe, A; Stöckel, R; Hohrein, D; Schöche, J
1998-01-01
The failure of intraventricular pressure measurement in cases of catheter blockage or dislodgement is thought to be eliminated by using intraventricular microtransducers. We report on an avoidable methodological error that may affect the reliability of intraventricular pressure measurement with these devices. Intraventricular fiberoptic or solid-state devices were implanted in 43 patients considered to be at risk for developing catheter occlusion. Two different types were used, i.e., devices in which the transducer is placed inside the ventriculostomy catheter (Type A) and devices in which the transducer is integrated in the external surface of the catheter (Type B). Type A devices were used in 15 patients and Type B devices in 28 patients. Pressure recordings were checked at bedside for the validity and reliability of the measurement. Of the 15 patients treated with Type A devices, no reliable pressure recordings were able to be obtained in three patients in whom ventricular punctures were not successful. In 4 of the remaining 12 patients, periods of erroneous pressure readings were detected. After opening of cerebrospinal fluid drainage, all Type A devices failed to reflect real intraventricular pressure. In patients treated with Type B devices, no erroneous pressure recordings were able to be identified, irrespective of whether cerebrospinal fluid drainage was performed. Even when ventricular puncture failed, pressure measurement was correct each time. Transducers that are simply placed inside the ventriculostomy catheter require fluid-coupling. They may fail, either during cerebrospinal fluid drainage or when the catheter is blocked or placed within the parenchyma.
A hybrid plasmonic waveguide terahertz quantum cascade laser
NASA Astrophysics Data System (ADS)
Degl'Innocenti, Riccardo; Shah, Yash D.; Wallis, Robert; Klimont, Adam; Ren, Yuan; Jessop, David S.; Beere, Harvey E.; Ritchie, David A.
2015-02-01
We present the realization of a quantum cascade laser emitting at around 2.85 THz, based on a hybrid plasmonic waveguide with a low refractive index dielectric cladding. This hybrid waveguide design allows the performance of a double-metal waveguide to be retained, while improving the emission far-field. A set of lasers based on the same active region material were fabricated with different metal layer thicknesses. A detailed characterization of the performance of these lasers revealed that there is an optimal trade-off that yields the best far-field emission and the maximum temperature of operation. By exploiting the pure plasmonic mode of these waveguides, the standard operation conditions of a double-metal quantum cascade laser were retrieved, such that the maximum operating temperature of these devices is not affected by the process. These results pave the way to realizing a class of integrated devices working in the terahertz range which could be further exploited to fabricate terahertz on-chip circuitry.
Control of epitaxial defects for optimal AlGaN/GaN HEMT performance and reliability
NASA Astrophysics Data System (ADS)
Green, D. S.; Gibb, S. R.; Hosse, B.; Vetury, R.; Grider, D. E.; Smart, J. A.
2004-12-01
High-quality GaN epitaxy continues to be challenged by the lack of matched substrates. Threading dislocations that result from heteroepitaxy are responsible for leakage currents, trapping effects, and may adversely affect device reliability. We have studied the impact of AlN nucleation conditions on the density and character of threading dislocations on SiC substrates. Variation of the nucleation temperature, V/III ratio, and thickness are seen to have a dramatic effect on the balance between edge, screw and mixed character dislocation densities. Electrical and structural properties have been assessed by AFM and XRD on a material level and through DC and RF performance at the device level. The ratio between dislocation characteristics has been established primarily through comparison of symmetric and asymmetric XRD rocking curve widths. The effect of each dislocation type on leakage current, RF power and reliability at 2 GHz, the targeted band for cell phone infrastructure applications, is discussed.
Sarritzu, Valerio; Sestu, Nicola; Marongiu, Daniela; Chang, Xueqing; Masi, Sofia; Rizzo, Aurora; Colella, Silvia; Quochi, Francesco; Saba, Michele; Mura, Andrea; Bongiovanni, Giovanni
2017-01-01
Metal-halide perovskite solar cells rival the best inorganic solar cells in power conversion efficiency, providing the outlook for efficient, cheap devices. In order for the technology to mature and approach the ideal Shockley-Queissier efficiency, experimental tools are needed to diagnose what processes limit performances, beyond simply measuring electrical characteristics often affected by parasitic effects and difficult to interpret. Here we study the microscopic origin of recombination currents causing photoconversion losses with an all-optical technique, measuring the electron-hole free energy as a function of the exciting light intensity. Our method allows assessing the ideality factor and breaks down the electron-hole recombination current into bulk defect and interface contributions, providing an estimate of the limit photoconversion efficiency, without any real charge current flowing through the device. We identify Shockley-Read-Hall recombination as the main decay process in insulated perovskite layers and quantify the additional performance degradation due to interface recombination in heterojunctions. PMID:28317883
A hybrid plasmonic waveguide terahertz quantum cascade laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Degl'Innocenti, Riccardo, E-mail: rd448@cam.ac.uk; Shah, Yash D.; Wallis, Robert
2015-02-23
We present the realization of a quantum cascade laser emitting at around 2.85 THz, based on a hybrid plasmonic waveguide with a low refractive index dielectric cladding. This hybrid waveguide design allows the performance of a double-metal waveguide to be retained, while improving the emission far-field. A set of lasers based on the same active region material were fabricated with different metal layer thicknesses. A detailed characterization of the performance of these lasers revealed that there is an optimal trade-off that yields the best far-field emission and the maximum temperature of operation. By exploiting the pure plasmonic mode of thesemore » waveguides, the standard operation conditions of a double-metal quantum cascade laser were retrieved, such that the maximum operating temperature of these devices is not affected by the process. These results pave the way to realizing a class of integrated devices working in the terahertz range which could be further exploited to fabricate terahertz on-chip circuitry.« less
NASA Astrophysics Data System (ADS)
Ratti, Lodovico; Gaioni, Luigi; Manghisoni, Massimo; Traversi, Gianluca; Pantano, Devis
2008-08-01
The purpose of this paper is to study the mechanisms underlying performance degradation in 130 nm and 90 nm commercial CMOS technologies exposed to high doses of ionizing radiation. The investigation has been mainly focused on their noise properties in view of applications to the design of low-noise, low-power analog circuits to be operated in harsh environment. Experimental data support the hypothesis that charge trapping in shallow trench isolation (STI), besides degrading the static characteristics of interdigitated NMOS transistors, also affects their noise performances in a substantial fashion. The model discussed in this paper, presented in a previous work focused on CMOS devices irradiated with a 10 Mrad(SiO2) gamma -ray dose, has been applied here also to transistors exposed to much higher (up to 100 Mrad(SiO2 )) doses of X-rays. Such a model is able to account for the extent of the observed noise degradation as a function of the device polarity, dimensions and operating point.
Graphene/h-BN/GaAs sandwich diode as solar cell and photodetector.
Li, Xiaoqiang; Lin, Shisheng; Lin, Xing; Xu, Zhijuan; Wang, Peng; Zhang, Shengjiao; Zhong, Huikai; Xu, Wenli; Wu, Zhiqian; Fang, Wei
2016-01-11
In graphene/semiconductor heterojunction, the statistic charge transfer between graphene and semiconductor leads to decreased junction barrier height and limits the Fermi level tuning effect in graphene, which greatly affects the final performance of the device. In this work, we have designed a sandwich diode for solar cells and photodetectors through inserting 2D hexagonal boron nitride (h-BN) into graphene/GaAs heterostructure to suppress the static charge transfer. The barrier height of graphene/GaAs heterojunction can be increased from 0.88 eV to 1.02 eV by inserting h-BN. Based on the enhanced Fermi level tuning effect with interface h-BN, through adopting photo-induced doping into the device, power conversion efficiency (PCE) of 10.18% has been achieved for graphene/h-BN/GaAs compared with 8.63% of graphene/GaAs structure. The performance of graphene/h-BN/GaAs based photodetector is also improved with on/off ratio increased by one magnitude compared with graphene/GaAs structure.
Novel application of a Wii remote to measure spasticity with the pendulum test: Proof of concept
Yeh, Chien-Hung; Hung, Chi-Yao; Wang, Yung-Hung; Hsu, Wei-Tai; Chang, Yi-Chung; Yeh, Jia-Rong; Lee, Po-Lei; Hu, Kun; Kang, Jiunn-Horng; Lo, Men-Tzung
2016-01-01
Background The pendulum test is a standard clinical test for quantifying the severity of spasticity. In the test, an electrogoniometer is typically used to measure the knee angular motion. The device is costly and difficult to set up such that the pendulum test is normally time consuming. Objective The goal of this study is to determine whether a Nintendo Wii remote can replace the electrogroniometer for reliable assessment of the angular motion of the knee in the pendulum test. Methods The pendulum test was performed in three control participants and 13 hemiplegic stroke patients using both a Wii remote and an electrogoniometer. The correlation coefficient and the Bland–Altman difference plot were used to compare the results obtained from the two devices. The Wilcoxon signed-rank test was used to compare the difference between hemiplegia-affected and nonaffected sides in the hemiplegic stroke patients. Results There was a fair to strong correlation between measurements from the Wii remote and the electrogoniometer (0.513 < R2 < 0.800). Small but consistent differences between the Wii remote and electrogoniometer were identified from the Bland–Altman difference plot. Within the hemiplegic stroke patients, both devices successfully distinguished the hemiplegia-affected (spastic) side from the nonaffected (nonspastic) side (both with p < .0001*). In addition, the intraclass correlation coefficient, standard error of measurement, and minimum detectable differences were highly consistent for both devices. Conclusion Our findings suggest that the Wii remote may serve as a convenient and cost-efficient tool for the assessment of spasticity. PMID:26669955
Novel application of a Wii remote to measure spasticity with the pendulum test: Proof of concept.
Yeh, Chien-Hung; Hung, Chi-Yao; Wang, Yung-Hung; Hsu, Wei-Tai; Chang, Yi-Chung; Yeh, Jia-Rong; Lee, Po-Lei; Hu, Kun; Kang, Jiunn-Horng; Lo, Men-Tzung
2016-01-01
The pendulum test is a standard clinical test for quantifying the severity of spasticity. In the test, an electrogoniometer is typically used to measure the knee angular motion. The device is costly and difficult to set up such that the pendulum test is normally time consuming. The goal of this study is to determine whether a Nintendo Wii remote can replace the electrogroniometer for reliable assessment of the angular motion of the knee in the pendulum test. The pendulum test was performed in three control participants and 13 hemiplegic stroke patients using both a Wii remote and an electrogoniometer. The correlation coefficient and the Bland-Altman difference plot were used to compare the results obtained from the two devices. The Wilcoxon signed-rank test was used to compare the difference between hemiplegia-affected and nonaffected sides in the hemiplegic stroke patients. There was a fair to strong correlation between measurements from the Wii remote and the electrogoniometer (0.513
NASA Astrophysics Data System (ADS)
Shi, Sheng-bing; Chen, Zhen-xing; Qin, Shao-gang; Song, Chun-yan; Jiang, Yun-hong
2014-09-01
With the development of science and technology, photoelectric equipment comprises visible system, infrared system, laser system and so on, integration, information and complication are higher than past. Parallelism and jumpiness of optical axis are important performance of photoelectric equipment,directly affect aim, ranging, orientation and so on. Jumpiness of optical axis directly affect hit precision of accurate point damage weapon, but we lack the facility which is used for testing this performance. In this paper, test system which is used fo testing parallelism and jumpiness of optical axis is devised, accurate aim isn't necessary and data processing are digital in the course of testing parallelism, it can finish directly testing parallelism of multi-axes, aim axis and laser emission axis, parallelism of laser emission axis and laser receiving axis and first acuualizes jumpiness of optical axis of optical sighting device, it's a universal test system.
NASA Astrophysics Data System (ADS)
Watson, Brett; Yeo, Leslie; Friend, James
2010-06-01
Making use of mechanical resonance has many benefits for the design of microscale devices. A key to successfully incorporating this phenomenon in the design of a device is to understand how the resonant frequencies of interest are affected by changes to the geometric parameters of the design. For simple geometric shapes, this is quite easy, but for complex nonlinear designs, it becomes significantly more complex. In this paper, two novel modeling techniques are demonstrated to extract the axial and torsional resonant frequencies of a complex nonlinear geometry. The first decomposes the complex geometry into easy to model components, while the second uses scaling techniques combined with the finite element method. Both models overcome problems associated with using current analytical methods as design tools, and enable a full investigation of how changes in the geometric parameters affect the resonant frequencies of interest. The benefit of such models is then demonstrated through their use in the design of a prototype piezoelectric ultrasonic resonant micromotor which has improved performance characteristics over previous prototypes.
Digital disruption? Maternal mobile device use is related to infant social-emotional functioning.
Myruski, Sarah; Gulyayeva, Olga; Birk, Samantha; Pérez-Edgar, Koraly; Buss, Kristin A; Dennis-Tiwary, Tracy A
2017-09-24
Mobile device use has become increasingly prevalent, yet its impact on infant development remains largely unknown. When parents use mobile devices in front of infants, the parent is physically present but most likely distracted and unresponsive. Research using the classic Still Face Paradigm (SFP) suggests that parental withdrawal and unresponsiveness may have negative consequences for children's social-emotional development. In the present study, 50 infants aged 7.20 to 23.60 months (M = 15.40, SD = 4.74) and their mothers completed a modified SFP. The SFP consisted of three phases: free play (FP; parent and infant play and interact), still face (SF; parent withdraws attention and becomes unresponsive), and reunion (RU; parent resumes normal interaction). The modified SFP incorporated mobile device use in the SF phase. Parents reported on their typical mobile device use and infant temperament. Consistent with the standard SFP, infants showed more negative affect and less positive affect during SF versus FP. Infants also showed more toy engagement and more engagement with mother during FP versus SF and RU. Infants showed the most social bids during SF and more room exploration in SF than RU. More frequent reported mobile device use was associated with less room exploration and positive affect during SF, and less recovery (i.e., engagement with mother, room exploration positive affect) during RU, even when controlling for individual differences in temperament. Findings suggest that the SFP represents a promising theoretical framework for understanding the impact of parent's mobile device use on infant social-emotional functioning and parent-infant interactions. © 2017 John Wiley & Sons Ltd.
The Role of a Mental Model in Learning to Operate a Device.
ERIC Educational Resources Information Center
Kieras, David E.; Bovair, Susan
1984-01-01
Describes three studies concerned with learning to operate a control panel device and how this learning is affected by understanding a device model that describes its internal mechanism. Results indicate benefits of a device model depend on whether it supports direct inference of exact steps required to operate the device. (Author/MBR)
Interconnection network architectures based on integrated orbital angular momentum emitters
NASA Astrophysics Data System (ADS)
Scaffardi, Mirco; Zhang, Ning; Malik, Muhammad Nouman; Lazzeri, Emma; Klitis, Charalambos; Lavery, Martin; Sorel, Marc; Bogoni, Antonella
2018-02-01
Novel architectures for two-layer interconnection networks based on concentric OAM emitters are presented. A scalability analysis is done in terms of devices characteristics, power budget and optical signal to noise ratio by exploiting experimentally measured parameters. The analysis shows that by exploiting optical amplifications, the proposed interconnection networks can support a number of ports higher than 100. The OAM crosstalk induced-penalty, evaluated through an experimental characterization, do not significantly affect the interconnection network performance.
NASA Technical Reports Server (NTRS)
Clancy, H. M.
1972-01-01
Vacuum stability screening tests were performed on the Apollo 15 Scientific Instrument Module (SIM) bay nonmetallic materials in accordance with the NASA document SP-R-0022. The testing was necessary to support the evaluation to determine the effect material outgassing contamination would have on the SIM bay optical lenses and sensing devices. The Apollo 15 SIM experiments were highly successful, therefore, it is assumed that contamination due to the outgassing of nonmetallic materials did not affect equipment operation. A related problem, the reversion of a silicone rubber grommet which affected an electrical motor switch operation is also reported.
Morone, Giovanni; Annicchiarico, Roberta; Iosa, Marco; Federici, Alessia; Paolucci, Stefano; Cortés, Ulises; Caltagirone, Carlo
2016-05-26
Patients affected by mild stroke benefit more from physiological overground walking training than walking-like training performed in place using specific devices. The aim of the study was to evaluate the effects of overground robotic walking training performed with the servo-assistive robotic rollator (i-Walker) on walking, balance, gait stability and falls in a community setting in patients with mild subacute stroke. Forty-four patients were randomly assigned to two different groups that received the same therapy in two daily 40-min sessions 5 days a week for 4 weeks. Twenty sessions of standard therapy were performed by both groups. In the other 20 sessions the subjects enrolled in the i-Walker-Group (iWG) performed with the i-Walker and the Control-Group patients (CG) performed the same amount of conventional walking oriented therapy. Clinical and instrumented gait assessments were made pre- and post-treatment. The follow-up observation consisted of recording the number of fallers in the community setting after 6 months. Treatment effectiveness was higher in the iWG group in terms of balance improvement (Tinetti: 68.4 ± 27.6 % vs. 48.1 ± 33.9 %, p = 0.033) and 10-m and 6-min timed walking tests (significant interaction between group and time: F(1,40) = 14.252, p = 0.001; and F(1,40) = 7.883, p = 0.008, respectively). When measured, latero-lateral upper body accelerations were reduced in iWG (F = 4.727, p = 0.036), suggesting increased gait stability, which was supported by a reduced number of falls at home. A robotic servo-assisted i-Walker improved walking performance and balance in patients affected by mild/moderate stroke, leading to increased gait stability and reduced falls in the community. This study was registered on anzctr.org.au (July 1, 2015; ACTRN12615000681550 ).
Comparison of hardness of three temporary filling materials cured by two light-curing devices.
Bodrumlu, E; Koçak, M M; Hazar Bodrumlu, E; Ozcan, S; Koçak, S
2014-01-01
Polymerization ability of light-curing devices can affect the light-cured material hardness. The purpose of the present study was to evaluate and compare the hardness of three temporary filling materials that had been light-cured by either a light emitting diode (LED) or a halogen light-curing unit. The temporary filling materials, First Fill, Voco Clip and Bioplic, were placed in wells in a Teflon plate. The 24 specimens of each material were divided into two groups (N.=12/group) for photo-activation by either of the two light-curing units. The LED or halogen device was applied for 40s to the top surface of each specimen. A Knoop hardness test was performed on the top and bottom surface of each specimen, with five measurements per specimen. The highest hardness values for both the LED and halogen treated groups were observed for First Fill and the lowest values were for Voco Clip in top and bottom surfaces. The hardness obtained for the three materials with the halogen unit were significantly higher than the values obtained with the LED unit in both surfaces (P<0.05). First Fill light-cured temporary material exhibited the highest hardness values on the top and bottom surfaces than Voco Clip and Bioplic temporary materials. The hardness of light-cured temporary filling materials can be affected by the type of light-curing unit.
Paxton, Elizabeth W; Inacio, Maria Cs; Kiley, Mary-Lou
2012-01-01
Considering the high cost, volume, and patient safety issues associated with medical devices, monitoring of medical device performance is critical to ensure patient safety and quality of care. The purpose of this article is to describe the Kaiser Permanente (KP) implant registries and to highlight the benefits of these implant registries on patient safety, quality, cost effectiveness, and research. Eight KP implant registries leverage the integrated health care system's administrative databases and electronic health records system. Registry data collected undergo quality control and validation as well as statistical analysis. Patient safety has been enhanced through identification of affected patients during major recalls, identification of risk factors associated with outcomes of interest, development of risk calculators, and surveillance programs for infections and adverse events. Effective quality improvement activities included medical center- and surgeon-specific profiles for use in benchmarking reports, and changes in practice related to registry information output. Among the cost-effectiveness strategies employed were collaborations with sourcing and contracting groups, and assistance in adherence to formulary device guidelines. Research studies using registry data included postoperative complications, resource utilization, infection risk factors, thromboembolic prophylaxis, effects of surgical delay on concurrent injuries, and sports injury patterns. The unique KP implant registries provide important information and affect several areas of our organization, including patient safety, quality improvement, cost-effectiveness, and research.
Robertson, Frederick A; Hoffman, George M
2004-03-01
Pulse oximetry manufacturers have introduced technologies that claim improved detection of hypoxemic events. Because improvements in signal processing and data rejection algorithms may differentially affect data reporting, we compared the data reporting and signal heuristic performance and agreement among the Nellcor N-395, Masimo SET, and GE Solar 8000 oximeters under a spectrum of conditions of signal integrity and arterial oxygen saturations. A blinded side-by-side comparison of technologies was performed in 27 patients, and data were analyzed for time of data availability, measures of agreement and signal heuristics, and warnings stratified by signal integrity and SpO(2). The Solar 8000 had less total data dropout than either of the new technologies. Masimo's LoSIQ (signal quality) heuristic rejected less data than Nellcor's MOT/PS (motion/pulse search) flag. When no signal heuristic was displayed, there was little difference in precision and bias between the two newer technologies; however, agreement between devices deteriorated in the presence of SIQ, MOT, or hypoxemia. Both newer devices flagged questionable data, but their use of different rejection algorithms resulted in different probabilities of presenting data. Therefore, with poor SIQ or during hypoxemia, the Nellcor N-395 and Masimo oximeters are not clinically equivalent to each other or to the older Solar 8000 oximeter. We compared new pulse oximeters from Nellcor and Masimo and found that, with good signal conditions, both new devices performed similarly to older technology. Overall, Masimo reported less data as questionable than Nellcor. With poor signal conditions or during hypoxemia, the new devices are not clinically equivalent to each other or to the older technology.
Lead-Free MA2CuCl(x)Br(4-x) Hybrid Perovskites.
Cortecchia, Daniele; Dewi, Herlina Arianita; Yin, Jun; Bruno, Annalisa; Chen, Shi; Baikie, Tom; Boix, Pablo P; Grätzel, Michael; Mhaisalkar, Subodh; Soci, Cesare; Mathews, Nripan
2016-02-01
Despite their extremely good performance in solar cells with efficiencies approaching 20% and the emerging application for light-emitting devices, organic-inorganic lead halide perovskites suffer from high content of toxic, polluting, and bioaccumulative Pb, which may eventually hamper their commercialization. Here, we present the synthesis of two-dimensional (2D) Cu-based hybrid perovskites and study their optoelectronic properties to investigate their potential application in solar cells and light-emitting devices, providing a new environmental-friendly alternative to Pb. The series (CH3NH3)2CuCl(x)Br(4-x) was studied in detail, with the role of Cl found to be essential for stabilization. By exploiting the additional Cu d-d transitions and appropriately tuning the Br/Cl ratio, which affects ligand-to-metal charge transfer transitions, the optical absorption in this series of compounds can be extended to the near-infrared for optimal spectral overlap with the solar irradiance. In situ formation of Cu(+) ions was found to be responsible for the green photoluminescence of this material set. Processing conditions for integrating Cu-based perovskites into photovoltaic device architectures, as well as the factors currently limiting photovoltaic performance, are discussed: among them, we identified the combination of low absorption coefficient and heavy mass of the holes as main limitations for the solar cell efficiency. To the best of our knowledge, this is the first demonstration of the potential of 2D copper perovskite as light harvesters and lays the foundation for further development of perovskite based on transition metals as alternative lead-free materials. Appropriate molecular design will be necessary to improve the material's properties and solar cell performance filling the gap with the state-of-the-art Pb-based perovskite devices.
Trudeau, Matthieu B.; Catalano, Paul J.; Jindrich, Devin L.; Dennerlein, Jack T.
2013-01-01
When holding a tablet computer with two hands, the touch keyboard configuration imposes postural constraints on the user because of the need to simultaneously hold the device and type with the thumbs. Designers have provided users with several possible keyboard configurations (device orientation, keyboard layout and location). However, potential differences in performance, usability and postures among these configurations have not been explored. We hypothesize that (1) the narrower standard keyboard layout in the portrait orientation leads to lower self-reported discomfort and less reach than the landscape orientation; (2) a split keyboard layout results in better overall outcomes compared to the standard layout; and (3) the conventional bottom keyboard location leads to the best outcomes overall compared to other locations. A repeated measures laboratory experiment of 12 tablet owners measured typing speed, discomfort, task difficulty, and thumb/wrist joint postures using an active marker system during typing tasks for different combinations of device orientation (portrait and landscape), keyboard layout (standard and split), and keyboard location (bottom, middle, top). The narrower standard keyboard with the device in the portrait orientation was associated with less discomfort (least squares mean (and S.E.) 2.9±0.6) than the landscape orientation (4.5±0.7). Additionally, the split keyboard decreased the amount of reaching required by the thumb in the landscape orientation as defined by a reduced range of motion and less MCP extension, which may have led to reduced discomfort (2.7±0.6) compared to the standard layout (4.5±0.7). However, typing speed was greater for the standard layout (127±5 char./min.) compared to the split layout (113±4 char./min.) regardless of device orientation and keyboard location. Usage guidelines and designers can incorporate these findings to optimize keyboard design parameters and form factors that promote user performance and usability for thumb interaction. PMID:23840730
Unified Numerical Solver for Device Metastabilities in CdTe Thin-Film PV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vasileska, Dragica
Thin-film modules of all technologies often suffer from performance degradation over time. Some of the performance changes are reversible and some are not, which makes deployment, testing, and energy-yield prediction more challenging. Manufacturers de-vote significant empirical efforts to study these phenomena and to improve semiconduc-tor device stability. Still, understanding the underlying reasons of these instabilities re-mains clouded due to the lack of ability to characterize materials at atomistic levels and the lack of interpretation from the most fundamental material science. The most com-monly alleged causes of metastability in CdTe device, such as “migration of Cu,” have been investigated rigorously overmore » the past fifteen years. Still, the discussion often ended prematurely with stating observed correlations between stress conditions and changes in atomic profiles of impurities or CV doping concentration. Multiple hypotheses sug-gesting degradation of CdTe solar cell devices due to interaction and evolution of point defects and complexes were proposed, and none of them received strong theoretical or experimental confirmation. It should be noted that atomic impurity profiles in CdTe pro-vide very little intelligence on active doping concentrations. The same elements could form different energy states, which could be either donors or acceptors, depending on their position in crystalline lattice. Defects interact with other extrinsic and intrinsic de-fects; for example, changing the state of an impurity from an interstitial donor to a sub-stitutional acceptor often is accompanied by generation of a compensating intrinsic in-terstitial donor defect. Moreover, all defects, intrinsic and extrinsic, interact with the elec-trical potential and free carriers so that charged defects may drift in the electric field and the local electrical potential affects the formation energy of the point defects. Such complexity of interactions in CdTe makes understanding of temporal changes in device performance even more challenging and a closed solution that can treat the entire sys-tem and its interactions is required.« less
Trudeau, Matthieu B; Catalano, Paul J; Jindrich, Devin L; Dennerlein, Jack T
2013-01-01
When holding a tablet computer with two hands, the touch keyboard configuration imposes postural constraints on the user because of the need to simultaneously hold the device and type with the thumbs. Designers have provided users with several possible keyboard configurations (device orientation, keyboard layout and location). However, potential differences in performance, usability and postures among these configurations have not been explored. We hypothesize that (1) the narrower standard keyboard layout in the portrait orientation leads to lower self-reported discomfort and less reach than the landscape orientation; (2) a split keyboard layout results in better overall outcomes compared to the standard layout; and (3) the conventional bottom keyboard location leads to the best outcomes overall compared to other locations. A repeated measures laboratory experiment of 12 tablet owners measured typing speed, discomfort, task difficulty, and thumb/wrist joint postures using an active marker system during typing tasks for different combinations of device orientation (portrait and landscape), keyboard layout (standard and split), and keyboard location (bottom, middle, top). The narrower standard keyboard with the device in the portrait orientation was associated with less discomfort (least squares mean (and S.E.) 2.9±0.6) than the landscape orientation (4.5±0.7). Additionally, the split keyboard decreased the amount of reaching required by the thumb in the landscape orientation as defined by a reduced range of motion and less MCP extension, which may have led to reduced discomfort (2.7±0.6) compared to the standard layout (4.5±0.7). However, typing speed was greater for the standard layout (127±5 char./min.) compared to the split layout (113±4 char./min.) regardless of device orientation and keyboard location. Usage guidelines and designers can incorporate these findings to optimize keyboard design parameters and form factors that promote user performance and usability for thumb interaction.
Marchal, Wouter; Verboven, Inge; Kesters, Jurgen; Moeremans, Boaz; De Dobbelaere, Christopher; Bonneux, Gilles; Elen, Ken; Conings, Bert; Maes, Wouter; Boyen, Hans Gerd; Deferme, Wim; Van Bael, Marlies; Hardy, An
2017-01-01
The identification, fine-tuning, and process optimization of appropriate hole transporting layers (HTLs) for organic solar cells is indispensable for the production of efficient and sustainable functional devices. In this study, the optimization of a solution-processed molybdenum oxide (MoOx) layer fabricated from a combustion precursor is carried out via the introduction of zirconium and tin additives. The evaluation of the output characteristics of both organic photovoltaic (OPV) and organic light emitting diode (OLED) devices demonstrates the beneficial influence upon the addition of the Zr and Sn ions compared to the generic MoOx precursor. A dopant effect in which the heteroatoms and the molybdenum oxide form a chemical identity with fundamentally different structural properties could not be observed, as the additives do not affect the molybdenum oxide composition or electronic band structure. An improved surface roughness due to a reduced crystallinity was found to be a key parameter leading to the superior performance of the devices employing modified HTLs. PMID:28772483
Brans, Toon; Strubbe, Filip; Schreuer, Caspar; Vandewiele, Stijn; Neyts, Kristiaan; Beunis, Filip
2015-09-01
Electric fields offer a variety of functionalities to Lab-on-a-Chip devices. The use of these fields often results in significant Joule heating, affecting the overall performance of the system. Precise knowledge of the temperature profile inside a microfluidic device is necessary to evaluate the implications of heat dissipation. This article demonstrates how an optically trapped microsphere can be used as a temperature probe to monitor Joule heating in these devices. The Brownian motion of the bead at room temperature is compared with the motion when power is dissipated in the system. This gives an estimate of the temperature increase at a specific location in a microfluidic channel. We demonstrate this method with solutions of different ionic strengths, and establish a precision of 0.9 K and an accuracy of 15%. Furthermore, it is demonstrated that transient heating processes can be monitored with this technique, albeit with a limited time resolution. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A Microfluidic Cell Concentrator
Warrick, Jay; Casavant, Ben; Frisk, Megan; Beebe, David
2010-01-01
Cell concentration via centrifugation is a ubiquitous step in many cell culture procedures. At the macroscale, centrifugation suffers from a number of limitations particularly when dealing with small numbers of cells (e.g., less than 50,000). On the other hand, typical microscale methods for cell concentration can affect cell physiology and bias readouts of cell behavior and function. In this paper, we present a microfluidic concentrator device that utilizes the effects of gravity to allow cells to gently settle out of a suspension into a collection region without the use of specific adhesion ligands. Dimensional analysis was performed to compare different device designs and was verified with flow modeling to optimize operational parameters. We are able to concentrate low-density cell suspensions in a microfluidic chamber, achieving a cell loss of only 1.1 ± 0.6% (SD, n=7) with no observed loss during a subsequent cell staining protocol which incorporates ~36 complete device volume replacements. This method provides a much needed interface between rare cell samples and microfluidic culture assays. PMID:20843010
Marchal, Wouter; Verboven, Inge; Kesters, Jurgen; Moeremans, Boaz; De Dobbelaere, Christopher; Bonneux, Gilles; Elen, Ken; Conings, Bert; Maes, Wouter; Boyen, Hans Gerd; Deferme, Wim; Van Bael, Marlies; Hardy, An
2017-01-30
The identification, fine-tuning, and process optimization of appropriate hole transporting layers (HTLs) for organic solar cells is indispensable for the production of efficient and sustainable functional devices. In this study, the optimization of a solution-processed molybdenum oxide (MoOx) layer fabricated from a combustion precursor is carried out via the introduction of zirconium and tin additives. The evaluation of the output characteristics of both organic photovoltaic (OPV) and organic light emitting diode (OLED) devices demonstrates the beneficial influence upon the addition of the Zr and Sn ions compared to the generic MoOx precursor. A dopant effect in which the heteroatoms and the molybdenum oxide form a chemical identity with fundamentally different structural properties could not be observed, as the additives do not affect the molybdenum oxide composition or electronic band structure. An improved surface roughness due to a reduced crystallinity was found to be a key parameter leading to the superior performance of the devices employing modified HTLs.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-23
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-1073] Complex Issues in Developing Medical Devices for Pediatric Patients Affected by Rare Diseases; Public Workshop; Request for Comments AGENCY: Food and Drug Administration, HHS. ACTION: Notice of public workshop...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steinmann, Vera; Chakraborty, Rupak; Rekemeyer, Paul
2016-11-21
As novel absorber materials are developed and screened for their photovoltaic (PV) properties, the challenge remains to rapidly test promising candidates in high-performing PV devices. There is a need to engineer new compatible device architectures, including the development of novel transparent conductive oxides and buffer layers. Here, we consider the two approaches of a substrate-style and a superstrate-style device architecture for novel thin-film solar cells. We use tin sulfide as a test absorber material. Upon device engineering, we demonstrate new approaches to improve device performance and performance reproducibility.
Customizing inhaled therapy to meet the needs of COPD patients.
Fromer, Leonard; Goodwin, Elizabeth; Walsh, John
2010-03-01
Chronic obstructive pulmonary disease (COPD) is a progressive disease characterized by airflow limitation resulting from emphysema and chronic bronchitis. Inhaled therapy is the major therapeutic approach for treating COPD. Multiple inhaler medications are available in the United States and are delivered by a variety of different devices: metered-dose inhalers, dry powdered inhalers, and nebulizers. Each inhaler device has unique requirements for use that must be correctly performed by the patient for successful drug delivery. Patients with COPD represent a medically diverse population, with each patient having distinct characteristics, such as lung function, comorbidities, cognitive functions, hand strength, and lifestyle. These characteristics impact the patient's ability to properly use specific inhaler devices and therefore affect adherence to therapy, therapeutic outcomes, and quality of life. It is estimated that between 28% to 68% of patients do not use metered-dose inhalers or dry powder inhalers correctly. Worsening symptoms or increased frequency of exacerbations may not always indicate disease progression but may indicate a patient's inability to use their inhaler device properly. This review discusses the patient- and device-specific factors to be considered when choosing an inhaled therapy, which will be concordant with the patient's medical needs, preferences, and lifestyle. The review also considers how the ideas underlying the patient-centered medical home model can be incorporated into the choice and use of inhaler device for a given patient with COPD to improve treatment outcomes.
Locata Performance Evaluation in the Presence of Wide- and Narrow-Band Interference
NASA Astrophysics Data System (ADS)
Khan, Faisal A.; Rizos, Chris; Dempster, Andrew G.
Classically difficult positioning environments often call for augmentation technology to assist the GPS, or more generally the Global Navigation Satellite System (GNSS) technology. The ground-based ranging technology offers augmentation, and even replacement, to GPS in such environments. However, like any other system relying on wireless technology, a Locata positioning network also faces issues in the presence of RF interference (RFI). This problem is magnified due to the fact that Locata operates in the licence-free 2·4 GHz Industrial, Scientific and Medical (ISM) band. The licence-free nature of this band attracts a much larger number of devices using a wider range of signal types than for licensed bands, resulting in elevation of the noise floor. Also, harmonics from out-of-band signals can act as potential interferers. WiFi devices operating in this band have been identified as the most likely potential interferer, due partially to their use of the whole ISM band, but also because Locata applications often also may use a wireless network. This paper evaluates the performance of Locata in the presence of both narrow- and wide-band interfering signals. Effects of received interference on both raw measurements and final solutions are reported and analysed. Test results show that Locata performance degrades in the presence of received interference. It is also identified that high levels of received interference can affect Locata carriers even if the interference is not in co-frequency situation with the affected carrier. Finally, Locata characteristics have been identified which can be exploited to mitigate RFI issues.
Anderson, Ted L; Yunker, Amanda C; Scheib, Stacey A; Callahan, Tamara L
2013-01-01
To determine factors associated with hysteroscopic sterilization success and whether it differs between the operating room and office settings. Retrospective cohort analysis (Canadian Task Force classification II-2). Major university medical center. Six hundred thirty-eight women who underwent hysteroscopic sterilization between July 1, 2005, and June 30, 2011. Data collected included age, body mass index, previous office procedures, previous cesarean section, and presence of myomas or retroverted uterus. Place of surgery, experience of surgeon, insurance type, bilateral device placement, compliance with hysterosalpingography, and confirmation of occlusion were also recorded. Bivariate analysis of patient characteristics between groups was performed using χ(2) and independent t tests, and identified confounders and associated variables. Multivariate analysis was performed using logistic regression to assess for association and to adjust for confounders. Procedures were performed in the operating room (57%) or in the office (43%). There was no association between success in bilateral device placement or occlusion and any patient characteristic, regardless of surgery setting. Private insurance, patient age, and performance of procedures in the office setting were positively associated with likelihood of compliance with hysterosalpingography. Successful device placement and tubal occlusion are independent of patient age, body mass index, or setting of the procedure. Association between insurance type and completing hysterosalpingography illustrates an important public health problem. Patients who fail to undergo hysterosalpingography to confirm tubal occlusion may unknowingly be at risk of pregnancy and increased risk of ectopic pregnancy. Copyright © 2013 AAGL. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Zulqarnain Haider, Syed; Anwar, Hafeez; Wang, Mingqing
2018-03-01
Hole transport material (HTM) plays an important role in the efficiency and stability of perovskite solar cells (PSCs). Spiro-MeOTAD, the commonly used HTM, is costly and can be easily degraded by heat and moisture, thus offering hindrance to commercialize PSCs. There is dire need to find an alternate inorganic and stable HTM to exploit PSCs with their maximum capability. In this paper, a comprehensive device simulation is used to study various possible parameters that can influence the performance of perovskite solar cell with CuI as HTM. These include the effect of doping density, defect density and thickness of absorber layer, along with the influence of diffusion length of carriers as well as electron affinity of electron transport layer (ETM) and HTM on the performance of PSCs. In addition, hole mobility and doping density of HTM is also investigated. CuI is a p-type inorganic material with low cost and relatively high stability. It is found that concentration of dopant in absorber layer and HTM, the electron affinity of HTM and ETM affect the performance of solar cell minutely, while cell performance improves greatly with the reduction of defect density. Upon optimization of parameters, power conversion efficiency for this device is found to be 21.32%. The result shows that lead-based PSC with CuI as HTM is an efficient system. Enhancing the stability and reduction of defect density are critical factors for future research. These factors can be improved by better fabrication process and proper encapsulation of solar cell.
Bourke, Henry E; Read, Jeremy; Kampa, Rebecca; Hearnden, Anthony; Davey, Paul A
2011-01-01
INTRODUCTION Carpal tunnel syndrome is the most common compression neuropathy affecting the upper limb. Clinical diagnosis is not always clear and electrophysiological testing can be indicated when considering a patient for decompression surgery. The downside of electrophysiological testing is cost and increased time to surgery. Newer methods of performing nerve conduction studies in clinic have become available. MATERIALS AND METHODS We investigated the use of a clinic-based, handheld, non-invasive electrophysiological device (NC-stat®) in 71 patients with suspected carpal tunnel syndrome presenting to our hand clinic in a district general hospital. We compared this to a similar cohort of 71 age-matched patients also presenting to our unit in whom formal nerve conduction studies were performed at a local neurophysiology unit. Our outcome measures were time from presentation to carpal tunnel decompression, the cost of each pathway and the practicalities of using the device in a busy hand unit. RESULTS AND CONCLUSIONS The NC-stat® proved to be a successful device when compared with referring patients out for more formal nerve conduction studies, shortening the time from presentation to surgery from 198 days to 102 days (p<0.0001). It was also cost effective with a calculated saving to the hospital of more than £70 per patient. The device is easy to use and acceptable to patients and no adverse effects were noted. PMID:21477439
Quantifying losses and thermodynamic limits in nanophotonic solar cells
NASA Astrophysics Data System (ADS)
Mann, Sander A.; Oener, Sebastian Z.; Cavalli, Alessandro; Haverkort, Jos E. M.; Bakkers, Erik P. A. M.; Garnett, Erik C.
2016-12-01
Nanophotonic engineering shows great potential for photovoltaics: the record conversion efficiencies of nanowire solar cells are increasing rapidly and the record open-circuit voltages are becoming comparable to the records for planar equivalents. Furthermore, it has been suggested that certain nanophotonic effects can reduce costs and increase efficiencies with respect to planar solar cells. These effects are particularly pronounced in single-nanowire devices, where two out of the three dimensions are subwavelength. Single-nanowire devices thus provide an ideal platform to study how nanophotonics affects photovoltaics. However, for these devices the standard definition of power conversion efficiency no longer applies, because the nanowire can absorb light from an area much larger than its own size. Additionally, the thermodynamic limit on the photovoltage is unknown a priori and may be very different from that of a planar solar cell. This complicates the characterization and optimization of these devices. Here, we analyse an InP single-nanowire solar cell using intrinsic metrics to place its performance on an absolute thermodynamic scale and pinpoint performance loss mechanisms. To determine these metrics we have developed an integrating sphere microscopy set-up that enables simultaneous and spatially resolved quantitative absorption, internal quantum efficiency (IQE) and photoluminescence quantum yield (PLQY) measurements. For our record single-nanowire solar cell, we measure a photocurrent collection efficiency of >90% and an open-circuit voltage of 850 mV, which is 73% of the thermodynamic limit (1.16 V).
Maxillary-driven simultaneous maxillo-mandibular distraction for hemifacial microsomia.
Nakajima, Hideo; Sakamoto, Yoshiaki; Tamada, Ikkei; Ogata, Hisao; Kishi, Kazuo; Sakamoto, Teruo
2011-12-01
We treat hemifacial microsomia with a combination of surgery and orthodontic treatment during the growth period, resulting in early improvement in facial asymmetry and the induction of normal growth. We previously used gradual distraction of the mandibular ramus for Pruzansky's type II classification (Pruzansky, 1969). In type II cases, the maxilla should also be treated actively as, using this technique, improvement of the occlusal plane is difficult to achieve, resulting in a cross bite and difficulties in post-operative orthodontic treatment-especially in older patients. Morphologically, the mandibular angle region of the operative side is flat, and the angle of the mouth remains elevated. We performed mandibular-driven simultaneous maxillo-mandibular distraction while the occlusion was maintained using intermaxillary anchorage. However, mandibular-driven distraction tended to elongate the face because the mandible only elongated downwards and the mandibular ramus did not reach the glenoid. Furthermore, external distraction devices produce significant distress for patients until removal of the device and cause scars on the face. We developed a new internal distraction device with a variable angle and performed maxillary-driven simultaneous maxillo-mandibular distraction using this device. The result was morphologically satisfactory and solved the above problems. Because the patient was in the growth period, careful follow-up and induction to normal growth were important while the inferior growth of the affected side was monitored. Copyright © 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Pathak, Anupam; Brei, Diann; Luntz, Jonathan
2009-03-01
Essential Tremor is a debilitating disorder that in the US alone is estimated to affect up to ten million people. Unfortunately current treatments (i.e. drug therapy and surgical procedures), are limited in effectiveness and often pose a risk of adverse side-effects. In response to this problem, this paper describes an active cancellation device based on a hand-held Shape Memory Alloy (SMA) actuated stabilization platform. The assistive device is designed to hold and stabilize various objects (e.g. eating utensils, tools, pointing implements, etc.) by sensing the user's tremor and moving the object in an opposite direction using SMA actuators configured in biologically inspired antagonistic pairs. To aid in the design, performance prediction and control of the device, a device model is described that accounts for the device kinematics, SMA thermo-mechanics, and the heat transfer resulting from electrical heating and convective cooling. The system of differential equations in this device model coupled with the controller gain can be utilized to design the operation given a frequency range and power requirement. To demonstrate this, a prototype was built and experimentally tested under external disturbances in the range of 1-5 Hz, resulting in amplitude reduction of up to 80%. The extent of cancellation measured for both single-frequencies and actual human tremor disturbances demonstrate the promise of this approach as a broadly used assistive device for the multitudes afflicted by tremor.
Dooley, Christopher J; Tenore, Francesco V; Gayzik, F Scott; Merkle, Andrew C
2018-04-27
Biological tissue testing is inherently susceptible to the wide range of variability specimen to specimen. A primary resource for encapsulating this range of variability is the biofidelity response corridor or BRC. In the field of injury biomechanics, BRCs are often used for development and validation of both physical, such as anthropomorphic test devices, and computational models. For the purpose of generating corridors, post-mortem human surrogates were tested across a range of loading conditions relevant to under-body blast events. To sufficiently cover the wide range of input conditions, a relatively small number of tests were performed across a large spread of conditions. The high volume of required testing called for leveraging the capabilities of multiple impact test facilities, all with slight variations in test devices. A method for assessing similitude of responses between test devices was created as a metric for inclusion of a response in the resulting BRC. The goal of this method was to supply a statistically sound, objective method to assess the similitude of an individual response against a set of responses to ensure that the BRC created from the set was affected primarily by biological variability, not anomalies or differences stemming from test devices. Copyright © 2018 Elsevier Ltd. All rights reserved.
Ureteroscopic biopsy of upper tract urothelial carcinoma: comparison of basket and forceps.
Kleinmann, Nir; Healy, Kelly A; Hubosky, Scott G; Margel, David; Bibbo, Marluce; Bagley, Demetrius H
2013-12-01
To compare two different biopsy devices for upper tract urothelial carcinoma (UTUC) and evaluate the pathologic result obtained by these devices. From January 2008 to December 2010, 414 ureteroscopies were performed and 504 biopsies were taken for evaluation of UTUC. Two biopsy devices were compared: 2.4F stainless steel flat wire basket and 3F cup biopsy forceps. The effect of the biopsy device on obtaining an adequate pathologic specimen was evaluated using univariate and multivariate binary logistic regression analysis. We also investigated whether tumor grade determination was affected by the biopsy device among patients with a diagnostic biopsy. Diagnosis was successful in 63% and 94% in the forceps and basket groups, respectively (P < 0.0001). Among biopsies with a definite diagnosis of UTUC, specific grade was determined in 80% and 93% in the forceps and basket groups, respectively (P = 0.033). In subgroup analysis of tumors larger than 10 mm in diameter, diagnosis was obtained in 80% and 94% in the forceps and basket groups, respectively (P = 0.037). Cytologic evaluation was found to increase diagnostic rates. The stainless steel flat wire basket was shown to be superior to the 3F cup biopsy forceps in terms of obtaining tissue diagnosis and providing specific grade.
Khedr, Maan; El-Sheimy, Nasser
2017-01-01
The growing market of smart devices make them appealing for various applications. Motion tracking can be achieved using such devices, and is important for various applications such as navigation, search and rescue, health monitoring, and quality of life-style assessment. Step detection is a crucial task that affects the accuracy and quality of such applications. In this paper, a new step detection technique is proposed, which can be used for step counting and activity monitoring for health applications as well as part of a Pedestrian Dead Reckoning (PDR) system. Inertial and Magnetic sensors measurements are analyzed and fused for detecting steps under varying step modes and device pose combinations using a free-moving handheld device (smartphone). Unlike most of the state of the art research in the field, the proposed technique does not require a classifier, and adaptively tunes the filters and thresholds used without the need for presets while accomplishing the task in a real-time operation manner. Testing shows that the proposed technique successfully detects steps under varying motion speeds and device use cases with an average performance of 99.6%, and outperforms some of the state of the art techniques that rely on classifiers and commercial wristband products. PMID:29117143
Gilger, B C; Wilkie, D A; Davidson, M G; Allen, J B
2001-12-01
To evaluate the use of an intravitreal sustained-release cyclosporine (CsA) delivery device for treatment of horses with naturally occurring recurrent uveitis. 16 horses with recurrent uveitis. Horses with frequent recurrent episodes of uveitis or with disease that was progressing despite appropriate medication were selected for this study. Additional inclusion criteria included adequate retinal function as determined by use of electroretinography, lack of severe cataract formation, and no vision-threatening ocular complications (eg, retinal detachment, severe retinal degeneration, and posterior synechia). Sustained-release CsA delivery devices (4 microg of CsA/d) were implanted into the vitreous through a sclerotomy at the pars plana. Reexaminations were performed 1, 3, 6, and 12 months after implantation, then continued annually. Ophthalmic changes, number of recurrent episodes of uveitis, and vision were recorded. The rate of recurrent episodes after device implantation (0.36 episodes/y) was less than prior to surgery (75 episodes/y). In addition, only 3 horses developed episodes of recurrent uveitis after surgery. Vision was detected in 14 of 16 affected eyes at a mean follow-up time of 13.8 months (range, 6 to 24 months). This intravitreal sustained-release CsA delivery device may be a safe and important tool for long-term treatment of horses with chronic recurrent uveitis.
Horn, Kevin M [Albuquerque, NM
2006-03-28
A scanned, pulsed, focused laser irradiation apparatus can measure and image the photocurrent collection resulting from a dose-rate equivalent exposure to infrared laser light across an entire silicon die. Comparisons of dose-rate response images or time-delay images from before, during, and after accelerated aging of a device, or from periodic sampling of devices from fielded operational systems allows precise identification of those specific age-affected circuit structures within a device that merit further quantitative analysis with targeted materials or electrical testing techniques. Another embodiment of the invention comprises a broad-beam, dose rate-equivalent exposure apparatus. The broad-beam laser irradiation apparatus can determine if aging has affected the device's overall functionality. This embodiment can be combined with the synchronized introduction of external electrical transients into a device under test to simulate the electrical effects of the surrounding circuitry's response to a radiation exposure.
NASA Astrophysics Data System (ADS)
Ozana, Nisan; Beiderman, Yevgeny; Anand, Arun; Javidi, Baharam; Polani, Sagi; Schwarz, Ariel; Shemer, Amir; Garcia, Javier; Zalevsky, Zeev
2016-06-01
We experimentally verify a speckle-based technique for noncontact measurement of glucose concentration in the bloodstream. The final device is intended to be a single wristwatch-style device containing a laser, a camera, and an alternating current (ac) electromagnet generated by a solenoid. The experiments presented are performed in vitro as proof of the concept. When a glucose substance is inserted into a solenoid generating an ac magnetic field, it exhibits Faraday rotation, which affects the temporal changes of the secondary speckle pattern distributions. The temporal frequency resulting from the ac magnetic field was found to have a lock-in amplification role, which increased the observability of the relatively small magneto-optic effect. Experimental results to support the proposed concept are presented.
Current at Metal-Organic Interfaces
NASA Astrophysics Data System (ADS)
Kern, Klaus
2012-02-01
Charge transport through atomic and molecular constrictions greatly affects the operation and performance of organic electronic devices. Much of our understanding of the charge injection and extraction processes in these systems relays on our knowledge of the electronic structure at the metal-organic interface. Despite significant experimental and theoretical advances in studying charge transport in nanoscale junctions, a microscopic understanding at the single atom/molecule level is missing. In the present talk I will present our recent results to probe directly the nanocontact between single molecules and a metal electrode using scanning probe microscopy and spectroscopy. The experiments provide unprecedented microscopic details of single molecule and atom junctions and open new avenues to study quantum critical and many body phenomena at the atomic scale. Implications for energy conversion devices and carbon based nanoelectronics will also be discussed.
Microfluidic PMMA interfaces for rectangular glass capillaries
NASA Astrophysics Data System (ADS)
Evander, Mikael; Tenje, Maria
2014-02-01
We present the design and fabrication of a polymeric capillary fluidic interface fabricated by micro-milling. The design enables the use of glass capillaries with any kind of cross-section in complex microfluidic setups. We demonstrate two different designs of the interface; a double-inlet interface for hydrodynamic focusing and a capillary interface with integrated pneumatic valves. Both capillary interfaces are presented together with examples of practical applications. This communication shows the design optimization and presents details of the fabrication process. The capillary interface opens up for the use of complex microfluidic systems in single-use glass capillaries. They also enable simple fabrication of glass/polymer hybrid devices that can be beneficial in many research fields where a pure polymer chip negatively affects the device's performance, e.g. acoustofluidics.
Probing molecular orientations in thin films by x-ray photoelectron spectroscopy
NASA Astrophysics Data System (ADS)
Li, Y.; Li, P.; Lu, Z.-H.
2018-03-01
A great number of functional organic molecules in active thin-film layers of optoelectronic devices have highly asymmetric structures, such as plate-like, rod-like, etc. This makes molecular orientation an important aspect in thin-films as it can significantly affect both the optical and electrical performance of optoelectronic devices. With a combination of in-situ ultra violet photoelectron spectroscopy (UPS) and x-ray photoelectron spectroscopy (XPS) investigations for organic molecules having a broad range of structural properties, we discovered a rigid connection of core levels and frontier highest occupied molecular orbital levels at organic interfaces. This finding opens up opportunities of using X-ray photoemission spectroscopy as an alternative tool to UPS for providing an easy and unambiguous data interpretation in probing molecular orientations.
Hyperbranched quasi-1D TiO2 nanostructure for hybrid organic-inorganic solar cells.
Ghadirzadeh, Ali; Passoni, Luca; Grancini, Giulia; Terraneo, Giancarlo; Li Bassi, Andrea; Petrozza, Annamaria; Di Fonzo, Fabio
2015-04-15
The performance of hybrid solar cells is strongly affected by the device morphology. In this work, we demonstrate a poly(3-hexylthiophene-2,5-diyl)/TiO2 hybrid solar cell where the TiO2 photoanode comprises an array of tree-like hyperbranched quasi-1D nanostructures self-assembled from the gas phase. This advanced architecture enables us to increase the power conversion efficiency to over 1%, doubling the efficiency with respect to state of the art devices employing standard mesoporous titania photoanodes. This improvement is attributed to several peculiar features of this array of nanostructures: high interfacial area; increased optical density thanks to the enhanced light scattering; and enhanced crystallization of poly(3-hexylthiophene-2,5-diyl) inside the quasi-1D nanostructure.
Current-induced changes of migration energy barriers in graphene and carbon nanotubes.
Obodo, J T; Rungger, I; Sanvito, S; Schwingenschlögl, U
2016-05-21
An electron current can move atoms in a nanoscale device with important consequences for the device operation and breakdown. We perform first principles calculations aimed at evaluating the possibility of changing the energy barriers for atom migration in carbon-based systems. In particular, we consider the migration of adatoms and defects in graphene and carbon nanotubes. Although the current-induced forces are large for both the systems, in graphene the force component along the migration path is small and therefore the barrier height is little affected by the current flow. In contrast, the same barrier is significantly reduced in carbon nanotubes as the current increases. Our work also provides a real-system numerical demonstration that current-induced forces within density functional theory are non-conservative.
Augmented Reality versus Virtual Reality for 3D Object Manipulation.
Krichenbauer, Max; Yamamoto, Goshiro; Taketom, Takafumi; Sandor, Christian; Kato, Hirokazu
2018-02-01
Virtual Reality (VR) Head-Mounted Displays (HMDs) are on the verge of becoming commodity hardware available to the average user and feasible to use as a tool for 3D work. Some HMDs include front-facing cameras, enabling Augmented Reality (AR) functionality. Apart from avoiding collisions with the environment, interaction with virtual objects may also be affected by seeing the real environment. However, whether these effects are positive or negative has not yet been studied extensively. For most tasks it is unknown whether AR has any advantage over VR. In this work we present the results of a user study in which we compared user performance measured in task completion time on a 9 degrees of freedom object selection and transformation task performed either in AR or VR, both with a 3D input device and a mouse. Our results show faster task completion time in AR over VR. When using a 3D input device, a purely VR environment increased task completion time by 22.5 percent on average compared to AR ( ). Surprisingly, a similar effect occurred when using a mouse: users were about 17.3 percent slower in VR than in AR ( ). Mouse and 3D input device produced similar task completion times in each condition (AR or VR) respectively. We further found no differences in reported comfort.
Yang, Mengjin; Zhang, Taiyang; Schulz, Philip; ...
2016-08-01
Organometallic halide perovskite solar cells (PSCs) have shown great promise as a low-cost, high-efficiency photovoltaic technology. Structural and electro-optical properties of the perovskite absorber layer are most critical to device operation characteristics. Here we present a facile fabrication of high-efficiency PSCs based on compact, large-grain, pinhole-free CH 3NH 3PbI 3-xBr x (MAPbI 3-xBr x) thin films with high reproducibility. A simple methylammonium bromide (MABr) treatment via spin-coating with a proper MABr concentration converts MAPbI 3 thin films with different initial film qualities (for example, grain size and pinholes) to high-quality MAPbI 3-xBr x thin films following an Ostwald ripening process,more » which is strongly affected by MABr concentration and is ineffective when replacing MABr with methylammonium iodide. A higher MABr concentration enhances I-Br anion exchange reaction, yielding poorer device performance. Lastly, this MABr-selective Ostwald ripening process improves cell efficiency but also enhances device stability and thus represents a simple, promising strategy for further improving PSC performance with higher reproducibility and reliability.« less
Raskin, Daniel; Khaitovich, Boris; Balan, Shmuel; Silverberg, Daniel; Halak, Moshe; Rimon, Uri
2018-01-01
To assess the technical success of the Outback reentry device in contralateral versus ipsilateral approaches for femoropopliteal arterial occlusion. A retrospective review of patients treated for critical limb ischemia (CLI) using the Outback between January 2013 and July 2016 was performed. Age, gender, length and site of the occlusion, approach site, aortic bifurcation angle, and reentry site were recorded. Calcification score was assigned at both aortic bifurcation and reentry site. Technical success was assessed. During the study period, a total of 1300 endovascular procedures were performed on 489 patients for CLI. The Outback was applied on 50 femoropopliteal chronic total occlusions. Thirty-nine contralateral and 11 ipsilateral antegrade femoral were accessed. The device was used successfully in 41 patients (82%). There were nine failures, all in the contralateral approach group. Six due to inability to deliver the device due to acute aortic bifurcation angle and three due to failure to achieve luminal reentry. Procedural success was significantly affected by the aortic bifurcation angle (p = 0.013). The Outback has high technical success rates in treatment of femoropopliteal occlusion, when applied from either an ipsi- or contralateral approach. When applied in contralateral access, acute aortic bifurcation angle predicts procedural failure.
NASA Astrophysics Data System (ADS)
Wohlschlögel, Markus; Steegmüller, Rainer; Schüßler, Andreas
2014-07-01
Nonmetallic inclusions in Nitinol, such as carbides (TiC) and intermetallic oxides (Ti4Ni2O x ), are known to be triggers for fatigue failure of Nitinol medical devices. These mechanically brittle inclusions are introduced during the melting process. As a result of hot and cold working in the production of Nitinol tubing inclusions are fractionalized due to the mechanical deformation imposed. While the role of inclusions regarding Nitinol fatigue performance has been studied extensively in the past, their effect on Nitinol corrosion behavior was investigated in only a limited number of studies. The focus of the present work was to understand the effect of inclusion size and distribution on the corrosion behavior of medical-device grade Nitinol tubing made from three different ingot sources during different manufacturing stages: (i) for the initial stage (hollow: round bar with centric hole), (ii) after hot drawing, and (iii) after the final drawing step (final tubing dimensions: outer diameter 0.3 mm, wall thickness 0.1 mm). For one ingot source, two different material qualities were investigated. Potentiodynamic polarization tests were performed for electropolished samples of the above-mentioned stages. Results indicate that inclusion size rather than inclusion quantity affects the susceptibility of electropolished Nitinol to pitting corrosion.
Sawtooth mitigation in 3D MHD tokamak modelling with applied magnetic perturbations
NASA Astrophysics Data System (ADS)
Bonfiglio, D.; Veranda, M.; Cappello, S.; Chacón, L.; Escande, D. F.
2017-01-01
The effect of magnetic perturbations (MPs) on the sawtoothing dynamics of the internal kink mode in the tokamak is discussed in the framework of nonlinear 3D MHD modelling. Numerical simulations are performed with the pixie3d code (Chacón 2008 Phys. Plasmas 15 056103) based on a D-shaped configuration in toroidal geometry. MPs are applied as produced by two sets of coils distributed along the toroidal direction, one set located above and the other set below the outboard midplane, like in experimental devices such as DIII-D and ASDEX Upgrade. The capability of n = 1 MPs to affect quasi-periodic sawteeth is shown to depend on the toroidal phase difference Δ φ between the perturbations produced by the two sets of coils. In particular, sawtooth mitigation is obtained for the Δ φ =π phasing, whereas no significant effect is observed for Δ φ =0 . Numerical findings are explained by the interplay between different poloidal harmonics in the spectrum of applied MPs, and appear to be consistent with experiments performed in the DIII-D device. Sawtooth mitigation and stimulation of self-organized helical states by applied MPs have been previously demonstrated in both circular tokamak and reversed-field pinch (RFP) experiments in the RFX-mod device, and in related 3D MHD modelling.
Buzzi, Jacopo; Ferrigno, Giancarlo; Jansma, Joost M.; De Momi, Elena
2017-01-01
Teleoperated robotic systems are widely spreading in multiple different fields, from hazardous environments exploration to surgery. In teleoperation, users directly manipulate a master device to achieve task execution at the slave robot side; this interaction is fundamental to guarantee both system stability and task execution performance. In this work, we propose a non-disruptive method to study the arm endpoint stiffness. We evaluate how users exploit the kinetic redundancy of the arm to achieve stability and precision during the execution of different tasks with different master devices. Four users were asked to perform two planar trajectories following virtual tasks using both a serial and a parallel link master device. Users' arm kinematics and muscular activation were acquired and combined with a user-specific musculoskeletal model to estimate the joint stiffness. Using the arm kinematic Jacobian, the arm end-point stiffness was derived. The proposed non-disruptive method is capable of estimating the arm endpoint stiffness during the execution of virtual teleoperated tasks. The obtained results are in accordance with the existing literature in human motor control and show, throughout the tested trajectory, a modulation of the arm endpoint stiffness that is affected by task characteristics and hand speed and acceleration. PMID:29018319
NASA Astrophysics Data System (ADS)
Sait, Usha; Muthuswamy, Sreekumar
2016-05-01
Dielectric electro active polymer (DEAP) is a suitable actuator material that finds wide applications in the field of robotics and medical areas. This material is highly controllable, flexible, and capable of developing large strain. The influence of geometrical behavior becomes critical when the material is used as miniaturized actuation devices in robotic applications. The present work focuses on the effect of surface topography on the performance of flat (single sheet) and stacked-rolled DEAP actuators. The non-active areas in the form of elliptical spots that affect the performance of the actuator are identified using scanning electron microscope (SEM) and energy dissipated X-ray (EDX) experiments. Performance of DEAP actuation is critically evaluated, compared, and presented with analytical and experimental results.
NASA Astrophysics Data System (ADS)
Badano, Aldo
1999-11-01
This thesis addresses the characterization of light scattering processes that degrade image quality in high performance electronic display devices for digital radiography. Using novel experimental and computational tools, we study the lateral diffusion of light in emissive display devices that causes extensive veiling glare and significant reduction of the physical contrast. In addition, we examine the deleterious effects of ambient light reflections that affect the contrast of low luminance regions, and superimpose unwanted structured signal. The analysis begins by introducing the performance limitations of the human visual system to define high fidelity requirements. It is noted that current devices severely suffer from image quality degradation due to optical transport processes. To model the veiling glare and reflectance characteristics of display devices, we introduce a Monte Carlo light transport simulation code, DETECT-II, that tracks individual photons through multiple scattering events. The simulation accounts for the photon polarization state at each scattering event, and provides descriptions for rough surfaces and thin film coatings. A new experimental method to measure veiling glare is described next, based on a conic collimated probe that minimizes contamination from bright areas. The measured veiling glare ratio is taken to be the luminance in the surrounding bright field divided by the luminance in the dark circle. We show that veiling glare ratios in the order of a few hundreds can be measured with an uncertainty of a few percent. The veiling glare response function is obtained by measuring the small spot contrast ratio of test patterns having varying dark spot radius. Using DETECT-II, we then estimate the ring response functions for a high performance medical imaging monitor of current design, and compare the predictions of the model with the experimentally measured response function. The data presented in this thesis demonstrate that although absorption in the faceplate of high performance monochrome cathode-ray tube monitors have reduced glare, a black matrix design is needed for high fidelity applications. For a high performance medical imaging monitor with anti-reflective coating, the glare ratio for a 1 cm diameter dark spot was measured to be 240. Finally, we introduce experimental techniques for measurements of specular and diffuse display reflectance, and we compare measured reflection coefficients with Monte Carlo estimates. A specular reflection coefficient of 0.0012, and a diffuse coefficient of 0.005 nits/lux are required to minimize degradation from ambient light in rooms with 100 lux illumination. In spite of having comparable reflection coefficients, the low maximum luminance of current devices worsens the effect of ambient light reflections when compared to radiographic film. Flat panel technologies with optimized designs can perform even better than film due to a thin faceplate, increased light absorption, and high brightness.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Xi; School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332; Thadesar, Paragkumar A.
2014-09-15
In-situ microscale thermomechanical strain measurements have been performed in combination with synchrotron x-ray microdiffraction to understand the fundamental cause of failures in microelectronics devices with through-silicon vias. The physics behind the raster scan and data analysis of the measured strain distribution maps is explored utilizing the energies of indexed reflections from the measured data and applying them for beam intensity analysis and effective penetration depth determination. Moreover, a statistical analysis is performed for the beam intensity and strain distributions along the beam penetration path to account for the factors affecting peak search and strain refinement procedure.
Ex-PRESS glaucoma filter: an MRI compatible metallic orbital foreign body imaged at 1.5 and 3T.
Mabray, M C; Uzelac, A; Talbott, J F; Lin, S C; Gean, A D
2015-05-01
To report on the MRI compatibility of the Ex-PRESS glaucoma filtration device, a tiny metallic implant placed into the anterior chamber of the eye that is much smaller than traditional glaucoma shunts, and to educate the radiology community regarding its appearance. Seven patients with Ex-PRESS glaucoma filtration devices were identified that had undergone MRI at San Francisco General Hospital/University of California San Francisco Medical Center by searching and cross-referencing the radiology reporting system and the electronic medical record. MRI images were reviewed for artefact interfering with interpretation. Ophthalmology examinations were reviewed for evidence of complications. Eighteen individual MRI examinations were performed during 12 unique MRI events on these 7 patients. 13/18 individual MRI examinations and 7/12 MRI events were performed at 3 T with the others performed at 1.5 T. Mean time from Ex-PRESS implantation to MRI was 17.5 months. Mean time from MRI to first ophthalmology examination was 1.1 months and from MRI to latest ophthalmology examination was 6.6 months. Susceptibility artefact did not interfere with image interpretation and no complications related to MRI were encountered. The Ex-PRESS glaucoma filtration device appears to be safe for MRI at 1.5 and 3 T and does not produce significant susceptibility artefact to affect diagnostic interpretation adversely. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Wang, Hao-Yi; Hao, Ming-Yang; Han, Jun; Yu, Man; Qin, Yujun; Zhang, Pu; Guo, Zhi-Xin; Ai, Xi-Cheng; Zhang, Jian-Ping
2017-03-17
Organic-inorganic halide perovskite solar cells have rapidly come to prominence in the photovoltaic field. In this context, CH 3 NH 3 PbI 3 , as the most widely adopted active layer, has been attracting great attention. Generally, in a CH 3 NH 3 PbI 3 layer, unreacted PbI 2 inevitably coexists with the perovskite crystals, especially following a two-step fabrication process. There appears to be a consensus that an appropriate amount of unreacted PbI 2 is beneficial to the overall photovoltaic performance of a device, the only disadvantageous aspect of excess residual PbI 2 being viewed as its insulating nature. However, the further development of such perovskite-based devices requires a deeper understanding of the role of residual PbI 2 . In this work, PbI 2 -enriched and PbI 2 -controlled perovskite films, as two extreme cases, have been prepared by modulating the crystallinity of a pre-deposited PbI 2 film. The effects of excess residual PbI 2 have been elucidated on the basis of spectroscopic and optoelectronic studies. The initial charge separation, the trap-state density, and the trap-state distribution have all been found to be adversely affected in PbI 2 -enriched devices, to the detriment of photovoltaic performance. This leads to a biphasic recombination process and accelerates the charge carrier recombination dynamics. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Pregnancy in women with Fowler's syndrome treated with sacral neuromodulation.
Khunda, Azar; Karmarkar, Roopali; Abtahi, Bahareh; Gonzales, Gwen; Elneil, Sohier
2013-07-01
Our aim was to determine the impact of pregnancy on sacral neuromodulation (SNM) and vice versa in patients with Fowler's syndrome (FS), which is typified by chronic urinary retention (CUR). We performed a retrospective study of pregnancy in patients with FS who underwent a two-stage SNM implantation. Data were obtained using a standard questionnaire and clinical interview. There were a total of ten patients with 13 pregnancies. The SNM was switched off in ten of the 13 pregnancies, with CUR recurring in nine of the ten pregnancies and recurrent urinary tract infections (UTI) occurring in four of these pregnancies (more than three UTI in the pregnancy). Those in whom the device was left on continued to void normally. One woman had a first trimester miscarriage, eight pregnancies went to term, and four deliveries were premature. Caesarean section was performed in eight pregnancies for obstetric reasons. Four pregnancies resulted in a vaginal delivery. There were no congenital anomalies reported. Following delivery, four of nine women experienced dysfunction of their SNM device when it was switched back on. Turing off the SNM during pregnancy results in recurrence of CUR, with an increased risk of recurrent UTI associated with preterm delivery. This did not impact foetal well-being. The option of keeping the SNM on during pregnancy should therefore be considered, and as caesarean section affects the SNM device, we advise that caesarean section should only be performed for obstetric reasons.
A Study of Al-Mn Transition Edge Sensor Engineering for Stability
DOE Office of Scientific and Technical Information (OSTI.GOV)
George, E. M.; et al.
2013-11-10
The stability of Al-Mn transition edge sensor (TES) bolometers is studied as we vary the engineered TES transition, heat capacity, and/or coupling between the heat capacity and TES. We present thermal structure measurements of each of the 39 designs tested. The data is accurately fit by a two-body bolometer model, which allows us to extract the basic TES parameters that affect device stability. We conclude that parameters affecting device stability can be engineered for optimal device operation, and present the model parameters extracted for the different TES designs.
Development of an ultra-low-shock separation nut
NASA Technical Reports Server (NTRS)
Woebkenberg, W.; Matteo, D. N.; Williams, V. D.
1982-01-01
The technical problems encountered in the development of an advanced separation nut design are described. The nut is capable of sustaining a large preload and releasing that load with a low level of induced pyrotechnic shock, while demonstrating a tolerance for extremely high shock imposed by other pyrotechnic devices. The analysis of the separation nut was performed to acquire additional understanding of the phenomena affecting operation of the nut and to provide quantitative evaluation of design modification for aerospace applications.
Samu, Gergely F.; Janaky, Csaba; Kamat, Prashant V.
2017-07-24
Photoinduced segregation in mixed halide perovskites has a direct influence on decreasing the solar cell efficiency as segregated I-rich domains serve as charge recombination centers. Here, the changes in the external quantum efficiency mirror the spectral loss in the absorption; however, the time scale of the IPCE recovery in the dark is slower than the absorption recovery, showing the intricate nature of the photoinduced halide segregation and charge collection in solar cell devices.
Operation of SOI P-Channel Field Effect Transistors, CHT-PMOS30, under Extreme Temperatures
NASA Technical Reports Server (NTRS)
Patterson, Richard; Hammoud, Ahmad
2009-01-01
Electronic systems are required to operate under extreme temperatures in NASA planetary exploration and deep space missions. Electronics on-board spacecraft must also tolerate thermal cycling between extreme temperatures. Thermal management means are usually included in today s spacecraft systems to provide adequate temperature for proper operation of the electronics. These measures, which may include heating elements, heat pipes, radiators, etc., however add to the complexity in the design of the system, increases its cost and weight, and affects its performance and reliability. Electronic parts and circuits capable of withstanding and operating under extreme temperatures would reflect in improvement in system s efficiency, reducing cost, and improving overall reliability. Semiconductor chips based on silicon-on-insulator (SOI) technology are designed mainly for high temperature applications and find extensive use in terrestrial well-logging fields. Their inherent design offers advantages over silicon devices in terms of reduced leakage currents, less power consumption, faster switching speeds, and good radiation tolerance. Little is known, however, about their performance at cryogenic temperatures and under wide thermal swings. Experimental investigation on the operation of SOI, N-channel field effect transistors under wide temperature range was reported earlier [1]. This work examines the performance of P-channel devices of these SOI transistors. The electronic part investigated in this work comprised of a Cissoid s CHT-PMOS30, high temperature P-channel MOSFET (metal-oxide semiconductor field-effect transistor) device [2]. This high voltage, medium-power transistor is designed for geothermal well logging applications, aerospace and avionics, and automotive industry, and is specified for operation in the temperature range of -55 C to +225 C. Table I shows some specifications of this transistor [2]. The CHT-PMOS30 device was characterized at various temperatures over the range of -190 C to +225 C in terms of its voltage/current characteristic curves. The test temperatures included +22, -50, -100, -150, -175, -190, +50, +100, +150, +175, +200, and +225 C. Limited thermal cycling testing was also performed on the device. These tests consisted of subjecting the transistor to a total of twelve thermal cycles between -190 C and +225 C. A temperature rate of change of 10 C/min and a soak time at the test temperature of 10 minutes were used throughout this work. Post-cycling measurements were also performed at selected temperatures. In addition, re-start capability at extreme temperatures, i.e. power switched on while the device was soaking for a period of 20 minutes at the test temperatures of -190 C and +225 C, was investigated.
Colcuc, Christian; Blank, Marc; Stein, Thomas; Raimann, Florian; Weber-Spickschen, Sanjay; Fischer, Sebastian; Hoffmann, Reinhard
2017-12-09
Suture button devices for tibiofibular syndesmosis injuries provide semirigid dynamic stabilization, but complications including knot irritation have been reported. No randomized trials of the new knotless suture button devices have been performed. We hypothesized that knotless suture button devices eliminate knot irritation and facilitate quicker return to sports. This study was performed to compare the clinical outcomes, complication rates, and time to return to sports between a new knotless suture button device and syndesmotic screw fixation. This study included 54 patients treated for ankle syndesmotic injury from 2012 to 2014 with a knotless suture button device or syndesmotic screw fixation. Clinical outcomes were measured using the American Orthopaedics Foot and Ankle Society score, Foot and Ankle Disability Index, Olerud and Molander score, and visual analog scale for pain and function. Secondary outcome measures were the complication rate and time required to return to sports. Patients underwent clinical and radiological evaluations preoperatively and three times during the 1-year postoperative follow-up. 54 of 62 eligible patients were analyzed, median age 37 (18-60) and underwent the 1-year follow-up. The screw fixation and knotless suture button groups comprised 26 and 28 patients, respectively. The complication rate was significantly lower (p = 0.03) and time to return to sports was significantly shorter in the knotless suture button than screw fixation group (average, 14 versus 19 weeks, respectively; p = 0.006). No significant differences were identified in clinical outcomes or visual analog scale scores for pain and function between the groups. Age, injury mechanism, and body mass index did not significantly affect the time required to return to sports activities. The type of fixation was the only independent variable that reached statistical significance (p = 0.006). Syndesmotic screw fixation and the new knotless suture button device both resulted in good clinical results. Lower complication rate and the earlier time to return to sports make the new knotless suture button device recommendable especially for highly active patients. Randomized controlled trial, Level I.
Krueger, Wesley W.O.
2010-01-01
Objectives/Hypotheses An eyewear mounted visual display (“User-worn see-through display”) projecting an artificial horizon aligned with the user's head and body position in space can prevent or lessen motion sickness in susceptible individuals when in a motion provocative environment as well as aid patients undergoing vestibular rehabilitation. In this project, a wearable display device, including software technology and hardware, was developed and a phase I feasibility study and phase II clinical trial for safety and efficacy were performed. Study Design Both phase I and phase II were prospective studies funded by the NIH. The phase II study used repeated measures for motion intolerant subjects and a randomized control group (display device/no display device) pre-post test design for patients in vestibular rehabilitation. Methods Following technology and display device development, 75 patients were evaluated by test and rating scales in the phase II study; 25 subjects with motion intolerance used the technology in the display device in provocative environments and completed subjective rating scales while 50 patients were evaluated before and after vestibular rehabilitation (25 using the display device and 25 in a control group) using established test measures. Results All patients with motion intolerance rated the technology as helpful for nine symptoms assessed, and 96% rated the display device as simple and easy to use. Duration of symptoms significantly decreased with use of the technology displayed. In patients undergoing vestibular rehabilitation, there were no significant differences in amount of change from pre- to post-therapy on objective balance tests between display device users and controls. However, those using the technology required significantly fewer rehabilitation sessions to achieve those outcomes than the control group. Conclusions A user-worn see-through display, utilizing a visual fixation target coupled with a stable artificial horizon and aligned with user movement, has demonstrated substantial benefit for individuals susceptible to motion intolerance and spatial disorientation and those undergoing vestibular rehabilitation. The technology developed has applications in any environment where motion sensitivity affects human performance. PMID:21181963
Yandell, Matthew B; Quinlivan, Brendan T; Popov, Dmitry; Walsh, Conor; Zelik, Karl E
2017-05-18
Wearable assistive devices have demonstrated the potential to improve mobility outcomes for individuals with disabilities, and to augment healthy human performance; however, these benefits depend on how effectively power is transmitted from the device to the human user. Quantifying and understanding this power transmission is challenging due to complex human-device interface dynamics that occur as biological tissues and physical interface materials deform and displace under load, absorbing and returning power. Here we introduce a new methodology for quickly estimating interface power dynamics during movement tasks using common motion capture and force measurements, and then apply this method to quantify how a soft robotic ankle exosuit interacts with and transfers power to the human body during walking. We partition exosuit end-effector power (i.e., power output from the device) into power that augments ankle plantarflexion (termed augmentation power) vs. power that goes into deformation and motion of interface materials and underlying soft tissues (termed interface power). We provide empirical evidence of how human-exosuit interfaces absorb and return energy, reshaping exosuit-to-human power flow and resulting in three key consequences: (i) During exosuit loading (as applied forces increased), about 55% of exosuit end-effector power was absorbed into the interfaces. (ii) However, during subsequent exosuit unloading (as applied forces decreased) most of the absorbed interface power was returned viscoelastically. Consequently, the majority (about 75%) of exosuit end-effector work over each stride contributed to augmenting ankle plantarflexion. (iii) Ankle augmentation power (and work) was delayed relative to exosuit end-effector power, due to these interface energy absorption and return dynamics. Our findings elucidate the complexities of human-exosuit interface dynamics during transmission of power from assistive devices to the human body, and provide insight into improving the design and control of wearable robots. We conclude that in order to optimize the performance of wearable assistive devices it is important, throughout design and evaluation phases, to account for human-device interface dynamics that affect power transmission and thus human augmentation benefits.
Mechanical and Controlled PRP Injections in Patients Affected by Androgenetic Alopecia.
Gentile, Pietro; Garcovich, Simone; Scioli, Maria Giovanna; Bielli, Alessandra; Orlandi, Augusto; Cervelli, Valerio
2018-01-27
23 patients (18 male and 5 female) aged 21-70 years who displayed male pattern hair loss (MPHL) in Stage 1 to Stage 5 as determined by the Norwood-Hamilton classification scale, and female pattern hair loss (FPHL) in Stage 1 to Stage 2 as determined by the Ludwig classification scale, were treated with non-activated autologous platelet-rich plasma (A-PRP). Autologous blood (55 mL) was harvested using sodium citrate as an anticoagulant. A-PRP (23 mL) was produced for all cases using a closed system according to the transfusion service protocol. Following centrifugation (260 x g for 10 min) the A-PRP was inserted in a laser light selector device, and after the centrifugation, 9 mL of A-PRP was collected. The scalp of the patients affected by androgenetic alopecia (AGA) was divided into four areas (frontal, parietal, vertex, and occipital); local anesthesia was not performed. Interfollicular A-PRP injections (0.2 mL x cm 2 ) were performed by controlled and mechanical injections scheduled at a depth of 5 mm using a medical injector gun. Treatment sessions were performed with a 30-day interval. For each patient, three treatment sessions were performed. PRP was injected in the androgen-related areas of scalp affected by hair loss. Placebo (normal saline solution) was loaded in another syringe (10 mL) and injected on the adjacent side in a similar fashion.
Improving the indoor air quality by using a surface emissions trap
NASA Astrophysics Data System (ADS)
Markowicz, Pawel; Larsson, Lennart
2015-04-01
The surface emissions trap, an adsorption cloth developed for reducing emissions of volatile organic compounds and particulate matter from surfaces while allowing evaporation of moisture, was used to improve the indoor air quality of a school building with elevated air concentrations of 2-ethyl-1-hexanol. An improvement of the perceived air quality was noticed a few days after the device had been attached on the PVC flooring. In parallel, decreased air concentrations of 2-ethyl-1-hexanol were found as well as a linear increase of the amounts of the same compound adsorbed on the installed cloth as observed up to 13 months after installation. Laboratory studies revealed that the performance of the device is not affected by differences in RH (35-85%), temperature (30-40 °C) or by accelerated aging simulating up to 10 years product lifetime, and, from a blinded exposure test, that the device efficiently blocks chemical odors. This study suggests that the device may represent a fast and efficient means of restoring the indoor air quality in a building e.g. after water damage leading to irritating and potentially harmful emissions from building material surfaces indoors.
Electrical gain in interband cascade infrared photodetectors
NASA Astrophysics Data System (ADS)
Huang, Wenxiang; Li, Lu; Lei, Lin; Massengale, Jeremy A.; Yang, Rui Q.; Mishima, Tetsuya D.; Santos, Michael B.
2018-03-01
In order to achieve improved understanding and gain insights into the device operation of interband cascade infrared photodetectors (ICIPs) and ultimately to optimize the design, we present a comparative study of five long-wavelength (LW) ICIPs based on a type-II InAs/GaSb superlattice. This study shows how the device responsivity is affected by the individual absorber thicknesses and the number of cascade stages, through the impact of light attenuation. Additionally, this study further validates that the electrical gain universally exists in non-current-matched ICIPs. With multiple cascade stages to suppress noise, these LW ICIPs achieved superior device performance at high temperatures, in terms of Johnson-noise limited detectivities, compared to commercial MCT detectors. Furthermore, a theory is developed to quantitatively describe the electrical gain in ICIPs and our calculations are in good agreement with the experimental results. Based on the theory, the optimal number of stages for maximizing the device detectivity D* is identified with inclusion of the electrical gain. Our calculation shows that this optimal number of stages is relatively large in the presence of the gain and the maximized D* has a relatively weak dependence on the absorber thickness when it is sufficiently thin.
Pogorzelec, Marta; Piekarska, Katarzyna
2018-08-01
The primary goal of the presented study was the investigation of occurrence and concentration of sixteen selected polycyclic aromatic hydrocarbons in samples from various stages of water treatment and verification of the applicability of semi-permeable membrane devices in the monitoring of drinking water. Another objective was to verify if weather seasons affect the concentration and complexity of PAHs. For these purposes, semipermeable membrane devices were installed in a surface water treatment plant located in Lower Silesia (Poland). Samples were collected monthly over a period of one year. To determine the effect of water treatment on PAH concentrations, four sampling sites were selected: raw water input, a stream of water in the pipe just before ozonation, treated water output and water after passing through the distribution system. After each month of sampling, SPMDs were exchanged for fresh ones and prepared for instrumental analysis. Concentrations of polycyclic aromatic hydrocarbons were determined by high-performance liquid chromatography (HPLC). The presented study indicates that semipermeable membrane devices can be an effective tool for the analysis of drinking water, in which organic micropollutants occur at very low concentrations. Copyright © 2018 Elsevier B.V. All rights reserved.
On electrode pinning and charge blocking layers in organic solar cells
NASA Astrophysics Data System (ADS)
Magen, Osnat; Tessler, Nir
2017-05-01
We use device modelling for studying the losses introduced by metallic electrodes in organic solar cells' device structure. We first discuss the inclusion of pinning at the integer charge transfer state in device models, with and without using the image charge potential. In the presence of disorder, the space charge introduced due to the image potential enhances the pinning by more than 0.2 eV. The explicit introduction of the image potential creates band-gap narrowing at the contact, thus affecting both dark leakage current and photo conversion efficiency. We find that there are two regimes in which the contacts may limit the performance. For low (moderate) barriers, the contacts introduce minority carrier recombination at the contacts that adds to the bulk recombination channels. Only for high barriers, the contacts directly limit the open circuit voltage and impose a value that is equal to the contact's energy difference. Examining the device structures with blocking layers, we find that these are mainly useful for the low to moderate contacts' barriers and that for the high barrier case, the enhancement of open circuit voltage may be accompanied by the introduction of serial resistance or S shape.
Smartphone-based fluorescence spectroscopy device aiding in preliminary skin screening
NASA Astrophysics Data System (ADS)
Sahoo, Aparajita; Wahi, Akshat; Das, Anshuman
2018-02-01
Preliminary diagnosis of closely resembling skin conditions can be highly subjective for dermatologists. In ambiguous cases, it often leads to performing invasive procedures like biopsies. Different skin conditions, however, have varying concentrations of fluorophores (like collagen, NADH) and chromophores (like melanin, hemoglobin) which can alter their fluorescence spectra. We demonstrate a handheld, portable, smartphone-based spectrometer that leverages these alterations in skin autofluorescence spectra for rapid screening of skin conditions. This methodology involves excitation of affected skin areas with ultraviolet (UV-A) 385 nm light, capturing the generated fluorescence spectra and sending the data wirelessly to a companion mobile application for data storage, analysis and visualization. By collecting the fluorescence spectral signals from healthy and unhealthy skin conditions, we establish that the signals collected using this portable device can be used to develop a classification method to help in differentially diagnosing these conditions. It shows promise as a useful skin screening tool for both dermatologists and primary health care workers. This device can enable quick, non-invasive and a more objective preliminary examination. We envision the device to be especially useful in primary healthcare centers of developing countries where availability of dermatologists is limited.
Harnessing Wind Power in Moving Reference Frames with Application to Vehicles
NASA Astrophysics Data System (ADS)
Goushcha, Oleg; Felicissimo, Robert; Danesh-Yazdi, Amir; Andreopoulos, Yiannis
2017-11-01
The extraction of wind power from unique configurations embedded in moving vehicles by using micro-turbine devices has been investigated. In such moving environments, the specific power of the air motion is much greater and less intermittent than in stationary wind turbines anchored to the ground in open atmospheric conditions. In a translational frame of reference, the rate of work done by the drag force acting on the wind harnessing device due the relative motion of air should be taken into account in the overall performance evaluation through an energy balance. A device with a venting tube has been tested that connects a high-pressure stagnating flow region in the front of the vehicle with a low-pressure region at its rear. Our analysis identified two key areas to focus on for potentially significant rewards: (1) Vehicles with high energy conversion efficiency which require a high mass flow rate through the venting duct, and (2) low efficiency vehicles with wakes, which will be globally affected by the introduction of the venting duct device in a manner that reduces their drag so that there is a net gain in power generation.
Electromagnetic Interference in Implantable Defibrillators in Single-Engine Fixed-Wing Aircraft.
de Rotte, Alexandra A J; van der Kemp, Peter; Mundy, Peter A; Rienks, Rienk; de Rotte, August A
2017-01-01
Little is known about the possible electromagnetic interferences (EMI) in the single-engine fixed-wing aircraft environment with implantable cardio-defibrillators (ICDs). Our hypothesis is that EMI in the cockpit of a single-engine fixed-wing aircraft does not result in erroneous detection of arrhythmias and the subsequent delivery of an inappropriate device therapy. ICD devices of four different manufacturers, incorporated in a thorax phantom, were transported in a Piper Dakota Aircraft with ICAO type designator P28B during several flights. The devices under test were programmed to the most sensitive settings for detection of electromagnetic signals from their environment. After the final flight the devices under test were interrogated with the dedicated programmers in order to analyze the number of tachycardias detected. Cumulative registration time of the devices under test was 11,392 min, with a mean of 2848 min per device. The registration from each one of the devices did not show any detectable "tachycardia" or subsequent inappropriate device therapy. This indicates that no external signals, which could be originating from electromagnetic fields from the aircraft's avionics, were detected by the devices under test. During transport in the cockpit of a single-engine fixed-wing aircraft, the tested ICDs did not show any signs of being affected by electromagnetic fields originating from the avionics of the aircraft. This current study indicates that EMI is not a potential safety issue for transportation of passengers with an ICD implanted in a single-engine fixed-wing aircraft.de Rotte AAJ, van der Kemp P, Mundy PA, Rienks R, de Rotte AA. Electromagnetic interference in implantable defibrillators in single-engine fixed-wing aircraft. Aerosp Med Hum Perform. 2017; 88(1):52-55.
The study of VOPc thin film transistors on modified substrates
NASA Astrophysics Data System (ADS)
Song, De; Xu, Qi; Cheng, Hongcang; Li, Bao-zeng; Shang, Yubin
2018-02-01
The vanadyl phthalocyanine (VOPc) organic thin film transistors (OTFTs) were fabricated on the various organosilane self-assembled monolayer (SAM) modified substrates. And the effect of the surface properties on the performance of these transistors was studied. The atomic force morphologies and X-ray diffraction (XRD) spectrums of vanadyl phthalocyanine films on different SAM-modified surfaces were studied. They reveal that the terminal functional groups of organosilane affect the growth of VOPc film and device performance. The VOPc film on octadecyltrichlorosilane (OTS) modified substrate has larger crystal size and effective crystal thickness than those on phenyltrichlorosilane (PTS), 1H,1H,2H,2H-Perfluorodec-yltrichlorosilane (FDTS) as well as non-modified substrate, which contributes the mobility of corresponding device several and several dozen times relative to other ones. The effective crystal thickness and crystal grain size of VOPc film on PTS is between that on OTS treated and that on non-modified substrate due to the stronger attractive force between VOPc and SiO2. The VOPc films' performance and effective crystal thickness on FDTS treated are worse than that on PTS due to the existents of attractive force between -CF3 and VOPc.
New getter configuration at wafer level for assuring long term stability of MEMs
NASA Astrophysics Data System (ADS)
Moraja, Marco; Amiotti, Marco; Kullberg, Richard C.
2003-01-01
The evolution from ceramic packages to wafer to wafer hermetic sealing poses tremendous technical challenges to integrate a proper getter inside the MEMs to assure a long term stability and reliability of the devices. The state of the art solution to integrate a getter inside the MEMs of the last generation consists in patterning the getter material with a specific geometry onto the Si cap wafer. The practical implementation of this solution consists in a 4" or 6" Si wafers with grooves or particular incisures, where the getter material is placed in form of a thick film. The typical thickness of these thick films is in the range of few microns, depending on the gas load to be handled during the lifetime of the device. The structure of the thick getter film is highly porous in order to improve sorption performances, but at the same time there are no loose particles thanks to a proprietary manufacturing method. The getter thick film is composed of a Zr special alloy with a proper composition to optimize the sorption performances. The getter thick film can be placed selectively into grooves without affecting the lateral regions, surrounding the grooves where the hermetic sealing is performed.
Multiphase flows with digital and traditional microfluidics
NASA Astrophysics Data System (ADS)
Nilsson, Michael A.
Multi-phase fluid systems are an important concept in fluid mechanics, seen every day in how fluids interact with solids, gases, and other fluids in many industrial, medical, agricultural, and other regimes. In this thesis, the development of a two-dimensional digital microfluidic device is presented, followed by the development of a two-phase microfluidic diagnostic tool designed to simulate sandstone geometries in oil reservoirs. In both instances, it is possible to take advantage of the physics involved in multiphase flows to affect positive outcomes in both. In order to make an effective droplet-based digital microfluidic device, one must be able to precisely control a number of key processes including droplet positioning, motion, coalescence, mixing, and sorting. For planar or open microfluidic devices, many of these processes have yet to be demonstrated. A suitable platform for an open system is a superhydrophobic surface, as suface characteristics are critical. Great efforts have been spent over the last decade developing hydrophobic surfaces exhibiting very large contact angles with water, and which allow for high droplet mobility. We demonstrate that sanding Teflon can produce superhydrophobic surfaces with advancing contact angles of up to 151° and contact angle hysteresis of less than 4°. We use these surfaces to characterize droplet coalescence, mixing, motion, deflection, positioning, and sorting. This research culminates with the presentation of two digital microfluidic devices: a droplet reactor/analyzer and a droplet sorter. As global energy usage increases, maximizing oil recovery from known reserves becomes a crucial multiphase challenge in order to meet the rising demand. This thesis presents the development of a microfluidic sandstone platform capable of quickly and inexpensively testing the performance of fluids with different rheological properties on the recovery of oil. Specifically, these microfluidic devices are utilized to examine how shear-thinning, shear-thickening, and viscoelastic fluids affect oil recovery. This work begins by looking at oil displacement from a microfluidic sandstone device, then investigates small-scale oil recovery from a single pore, and finally investigates oil displacement from larger scale, more complex microfluidic sandstone devices of varying permeability. The results demonstrate that with careful fluid design, it is possible to outperform current commercial additives using the patent-pending fluid we developed. Furthermore, the resulting microfluidic sandstone devices can reduce the time and cost of developing and testing of current and new enhanced oil recovery fluids.
Electrochemical sensing using voltage-current time differential
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woo, Leta Yar-Li; Glass, Robert Scott; Fitzpatrick, Joseph Jay
2017-02-28
A device for signal processing. The device includes a signal generator, a signal detector, and a processor. The signal generator generates an original waveform. The signal detector detects an affected waveform. The processor is coupled to the signal detector. The processor receives the affected waveform from the signal detector. The processor also compares at least one portion of the affected waveform with the original waveform. The processor also determines a difference between the affected waveform and the original waveform. The processor also determines a value corresponding to a unique portion of the determined difference between the original and affected waveforms.more » The processor also outputs the determined value.« less
49 CFR 232.405 - Design and performance standards for two-way end-of-train devices.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Design and performance standards for two-way end... Design and performance standards for two-way end-of-train devices. Two-way end-of-train devices shall be designed and perform with the features applicable to one-way end-of-train devices described in § 232.403...
49 CFR 232.405 - Design and performance standards for two-way end-of-train devices.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Design and performance standards for two-way end... Design and performance standards for two-way end-of-train devices. Two-way end-of-train devices shall be designed and perform with the features applicable to one-way end-of-train devices described in § 232.403...
49 CFR 232.405 - Design and performance standards for two-way end-of-train devices.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Design and performance standards for two-way end... Design and performance standards for two-way end-of-train devices. Two-way end-of-train devices shall be designed and perform with the features applicable to one-way end-of-train devices described in § 232.403...
49 CFR 232.405 - Design and performance standards for two-way end-of-train devices.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Design and performance standards for two-way end... Design and performance standards for two-way end-of-train devices. Two-way end-of-train devices shall be designed and perform with the features applicable to one-way end-of-train devices described in § 232.403...
Brusk, John J; Bensley, Robert J
2016-11-15
Online health education has expanded its reach due to cost-effective implementation and demonstrated effectiveness. However, a limitation exists with the evaluation of online health education implementations and how the impact of the system is attenuated by the extent to which a user engages with it. Moreover, the current online health education research does not consider how this engagement has been affected by the transition from fixed to mobile user access over the last decade. This paper focuses on comparing the impact mobile versus fixed devices have on user engagement key performance indicators (KPI) associated with the wichealth website (.org), an Internet-based parent-child feeding intervention offered to clients associated with the US Department of Agriculture's Special Supplemental Nutrition Program for Women, Infants, and Children (WIC). Data were collected from 612,201 nutrition education lessons completed by 305,735 unique WIC participants in 21 states over a 1-year period. Data consisted of system-collected measures, profile items, and items from an exit survey administered at the conclusion of each lesson. User engagement was defined based on 3 KPIs associated with usage of the wichealth website: number of link views, link view time, and progression in stage of readiness to change. Independent samples t tests were used to compare KPIs between fixed only and mobile only device users and paired samples t tests were used to compare KPIs within users who completed at least one lesson each on both a fixed and mobile device. A logistic regression was performed to estimate the odds of KPI performance thresholds in the independent samples study group given access device type while controlling for confounding of user characteristics associated with these KPIs. Analysis of 8 user characteristics (lessons completed, race, ethnicity, language, state of residence, pregnancy status, beginning stage of change, and preferred nutrition education method) were significantly (P<.001) related to various KPI differences between mobile and fixed device access. Non-mobile users were significantly (P<.001) more likely to engage based on all 3 KPIs, even after logistic regression control for the potential confounding related to the strongly associated user characteristics identified. The findings of this study support the idea that online health education developers need to seriously consider access device when creating programs. Online health education developers need to take extra effort to truly understand access patterns of populations being served, and whether or not access device will influence user engagement performance indicators. ©John J Brusk, Robert J Bensley. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 15.11.2016.
Shared performance monitor in a multiprocessor system
Chiu, George; Gara, Alan G.; Salapura, Valentina
2012-07-24
A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU comprises: a plurality of performance counters each for counting signals representing occurrences of events from one or more the plurality of processor units in the multiprocessor system; and, a plurality of input devices for receiving the event signals from one or more processor devices of the plurality of processor units, the plurality of input devices programmable to select event signals for receipt by one or more of the plurality of performance counters for counting, wherein the PMU is shared between multiple processing units, or within a group of processors in the multiprocessing system. The PMU is further programmed to monitor event signals issued from non-processor devices.
Hengge, Ulrich R; Röschmann, Kristina; Candler, Henning
2017-01-01
Psoriasis is a frequent inflammatory skin disease affecting ~2%-3% of the population in western countries. Scaling of the psoriatic lesions is the most impairing symptom in patients with psoriasis. In contrast to conventional keratolytic treatment concepts containing salicylic acid or urea, a dimeticone-based medical device (Loyon ® ) removes scales in a physical way without any pharmacological effect. To assess the efficacy and tolerability of a dimeticone-based medical device in removal of scales in patients with psoriasis corporis/capitis under real-life conditions. Forty patients with psoriasis capitis or corporis were included and received once-daily treatments for 7 days. Clinical assessment of the psoriasis area severity index score (psoriasis corporis) and the psoriasis scalp severity index score (psoriasis capitis) was performed and evaluated at baseline, after 3 and 7 days of treatment. Baseline scaling scores and redness scores were calculated for two target lesions of the scalp or the body on a 5-point scale each. For the primary efficacy variable scaling score, a statistically significant decrease was observed after treatment, with a relative reduction in scaling of 36.8% after 7 days of treatment within patients affected by psoriasis capitis. Treatment success was achieved in 76.8% of patients with psoriasis capitis, and time to treatment success was evaluated to be 4.14 days for these patients and 4.33 days for patients suffering from psoriasis corporis. In conclusion, this trial demonstrated that the dimeticone-based medical device is a safe, well-tolerated, practicable, and efficient keratolytic compound, which can be well implemented in and recommended for standard therapy of psoriasis.
Hengge, Ulrich R; Röschmann, Kristina; Candler, Henning
2017-01-01
Introduction Psoriasis is a frequent inflammatory skin disease affecting ~2%–3% of the population in western countries. Scaling of the psoriatic lesions is the most impairing symptom in patients with psoriasis. In contrast to conventional keratolytic treatment concepts containing salicylic acid or urea, a dimeticone-based medical device (Loyon®) removes scales in a physical way without any pharmacological effect. Objective To assess the efficacy and tolerability of a dimeticone-based medical device in removal of scales in patients with psoriasis corporis/capitis under real-life conditions. Methods Forty patients with psoriasis capitis or corporis were included and received once-daily treatments for 7 days. Clinical assessment of the psoriasis area severity index score (psoriasis corporis) and the psoriasis scalp severity index score (psoriasis capitis) was performed and evaluated at baseline, after 3 and 7 days of treatment. Baseline scaling scores and redness scores were calculated for two target lesions of the scalp or the body on a 5-point scale each. Results For the primary efficacy variable scaling score, a statistically significant decrease was observed after treatment, with a relative reduction in scaling of 36.8% after 7 days of treatment within patients affected by psoriasis capitis. Treatment success was achieved in 76.8% of patients with psoriasis capitis, and time to treatment success was evaluated to be 4.14 days for these patients and 4.33 days for patients suffering from psoriasis corporis. Conclusion In conclusion, this trial demonstrated that the dimeticone-based medical device is a safe, well-tolerated, practicable, and efficient keratolytic compound, which can be well implemented in and recommended for standard therapy of psoriasis. PMID:29387607
An Exploration of Pre-Service Teachers' Intention to Use Mobile Devices for Teaching
ERIC Educational Resources Information Center
Hur, Jung Won; Shen, Ying W.; Kale, Ugur; Cullen, Theresa A.
2015-01-01
Teachers in the US have been increasingly adopting mobile devices for teaching, but little research has examined how pre-service teachers perceive mobile device integration in classrooms. To address this issue, the study developed a research model that explained factors affecting pre-service teachers' intention to use mobile devices and the…
40 CFR 1700.14 - Marine Pollution Control Device (MPCD) Performance Standards. [Reserved
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Marine Pollution Control Device (MPCD... UNIFORM NATIONAL DISCHARGE STANDARDS FOR VESSELS OF THE ARMED FORCES Marine Pollution Control Device (MPCD) Performance Standards § 1700.14 Marine Pollution Control Device (MPCD) Performance Standards. [Reserved] ...
40 CFR 1700.14 - Marine Pollution Control Device (MPCD) Performance Standards. [Reserved
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Marine Pollution Control Device (MPCD... UNIFORM NATIONAL DISCHARGE STANDARDS FOR VESSELS OF THE ARMED FORCES Marine Pollution Control Device (MPCD) Performance Standards § 1700.14 Marine Pollution Control Device (MPCD) Performance Standards. [Reserved] ...
40 CFR 1700.14 - Marine Pollution Control Device (MPCD) Performance Standards. [Reserved
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Marine Pollution Control Device (MPCD... UNIFORM NATIONAL DISCHARGE STANDARDS FOR VESSELS OF THE ARMED FORCES Marine Pollution Control Device (MPCD) Performance Standards § 1700.14 Marine Pollution Control Device (MPCD) Performance Standards. [Reserved] ...
40 CFR 1700.14 - Marine Pollution Control Device (MPCD) Performance Standards. [Reserved
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Marine Pollution Control Device (MPCD... UNIFORM NATIONAL DISCHARGE STANDARDS FOR VESSELS OF THE ARMED FORCES Marine Pollution Control Device (MPCD) Performance Standards § 1700.14 Marine Pollution Control Device (MPCD) Performance Standards. [Reserved] ...
40 CFR 1700.14 - Marine Pollution Control Device (MPCD) Performance Standards. [Reserved
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Marine Pollution Control Device (MPCD... UNIFORM NATIONAL DISCHARGE STANDARDS FOR VESSELS OF THE ARMED FORCES Marine Pollution Control Device (MPCD) Performance Standards § 1700.14 Marine Pollution Control Device (MPCD) Performance Standards. [Reserved] ...
Voluntary Enhancement of Neural Signatures of Affiliative Emotion Using fMRI Neurofeedback
Moll, Jorge; Weingartner, Julie H.; Bado, Patricia; Basilio, Rodrigo; Sato, João R.; Melo, Bruno R.; Bramati, Ivanei E.; de Oliveira-Souza, Ricardo; Zahn, Roland
2014-01-01
In Ridley Scott’s film “Blade Runner”, empathy-detection devices are employed to measure affiliative emotions. Despite recent neurocomputational advances, it is unknown whether brain signatures of affiliative emotions, such as tenderness/affection, can be decoded and voluntarily modulated. Here, we employed multivariate voxel pattern analysis and real-time fMRI to address this question. We found that participants were able to use visual feedback based on decoded fMRI patterns as a neurofeedback signal to increase brain activation characteristic of tenderness/affection relative to pride, an equally complex control emotion. Such improvement was not observed in a control group performing the same fMRI task without neurofeedback. Furthermore, the neurofeedback-driven enhancement of tenderness/affection-related distributed patterns was associated with local fMRI responses in the septohypothalamic area and frontopolar cortex, regions previously implicated in affiliative emotion. This demonstrates that humans can voluntarily enhance brain signatures of tenderness/affection, unlocking new possibilities for promoting prosocial emotions and countering antisocial behavior. PMID:24847819
Shared performance monitor in a multiprocessor system
Chiu, George; Gara, Alan G; Salapura, Valentina
2014-12-02
A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU is further programmed to monitor event signals issued from non-processor devices.
78 FR 68714 - Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-15
... the device materials must be performed; (iv) Performance data must demonstrate acceptable mechanical properties under simulated clinical use conditions including insertion and removal of the device; (v...
Khatiwada, Devendra; Venkatesan, Swaminathan; Chen, QIliang; ...
2015-07-03
In this work, we report improved performance by controlling morphology using different fullerene derivatives in poly{2-octyldodecyloxy-benzo[1,2-b;3,4-b]dithiophene-alt-5,6-bis(dodecyloxy)-4,7- di(thieno[3,2-b]thiophen-2-yl)-benzo[c][1,2,5]thiadiazole} (PBDT-TBT-alkoBT) based organic solar cells. PC60BM and PC70BM fullerenes were used to investigate the characteristic change in morphology and device performance. Fullerene affects device efficiency by changing active layer morphology. PC70BM with broader absorption than PC 60BM resulted in reduced device performance which was elucidated by the intermixed granular morphology separating each larger grain in the PC70BM/polymer composite layer which created higher density of traps. However after adding additive 1,8-diiodooctane (DIO), the fibrous morphology was observed due to reduced solubility of polymer andmore » increased solubility of PC 70BM in chloroform. The fibrous morphology improved charge transport leading to increase in overall device performance. Atomic force microscopies (AFM), photo induced charge extraction by linearly increasing voltage (photo-CELIV), and Kelvin prove force microscope (KPFM) were used to investigate nanoscale morphology of active layer with different fullerene derivatives. For PC 60BM based active layer, AFM images revealed dense fibrous morphology and more distinct fibrous morphology was observed by adding DIO. The PC 70BM based active layer only exhibited intermixed granular morphology instead of fibrous morphology observed in PC60BM based active layer. However, addition of DIO in PC 70BM based active layer led to fibrous morphology. When additive DIO was not used, a wider distribution of surface potential was observed for PC 70BM than PC 60BM based active layer by KPFM measurements, indicating 2 polymer and fullerene domains are separated. When DIO was used, narrower distribution of surface potential for both PC 70BM and PC 60BM based active layers was observed. Photo-CELIV experiment showed larger extracted charge carrier density and mobility in PC 70BM/DIO film.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khatiwada, Devendra; Venkatesan, Swaminathan; Chen, QIliang
In this work, we report improved performance by controlling morphology using different fullerene derivatives in poly{2-octyldodecyloxy-benzo[1,2-b;3,4-b]dithiophene-alt-5,6-bis(dodecyloxy)-4,7- di(thieno[3,2-b]thiophen-2-yl)-benzo[c][1,2,5]thiadiazole} (PBDT-TBT-alkoBT) based organic solar cells. PC60BM and PC70BM fullerenes were used to investigate the characteristic change in morphology and device performance. Fullerene affects device efficiency by changing active layer morphology. PC70BM with broader absorption than PC 60BM resulted in reduced device performance which was elucidated by the intermixed granular morphology separating each larger grain in the PC70BM/polymer composite layer which created higher density of traps. However after adding additive 1,8-diiodooctane (DIO), the fibrous morphology was observed due to reduced solubility of polymer andmore » increased solubility of PC 70BM in chloroform. The fibrous morphology improved charge transport leading to increase in overall device performance. Atomic force microscopies (AFM), photo induced charge extraction by linearly increasing voltage (photo-CELIV), and Kelvin prove force microscope (KPFM) were used to investigate nanoscale morphology of active layer with different fullerene derivatives. For PC 60BM based active layer, AFM images revealed dense fibrous morphology and more distinct fibrous morphology was observed by adding DIO. The PC 70BM based active layer only exhibited intermixed granular morphology instead of fibrous morphology observed in PC60BM based active layer. However, addition of DIO in PC 70BM based active layer led to fibrous morphology. When additive DIO was not used, a wider distribution of surface potential was observed for PC 70BM than PC 60BM based active layer by KPFM measurements, indicating 2 polymer and fullerene domains are separated. When DIO was used, narrower distribution of surface potential for both PC 70BM and PC 60BM based active layers was observed. Photo-CELIV experiment showed larger extracted charge carrier density and mobility in PC 70BM/DIO film.« less
Optical-to-optical interface device
NASA Technical Reports Server (NTRS)
Jacobson, A. D.; Bleha, W. P.; Miller, L.; Grinberg, J.; Fraas, L.; Margerum, D.
1975-01-01
An investigation was conducted to develop an optical-to-optical interface device capable of performing real-time incoherent-to-incoherent optical image conversion. The photoactivated liquid crystal light valve developed earlier represented a prototype liquid crystal light valve device capable of performing these functions. A device was developed which had high performance and extended lifetime.
Spontaneous vortex nanodomain arrays at ferroelectric heterointerfaces.
Nelson, Christopher T; Winchester, Benjamin; Zhang, Yi; Kim, Sung-Joo; Melville, Alexander; Adamo, Carolina; Folkman, Chad M; Baek, Seung-Hyub; Eom, Chang-Beom; Schlom, Darrell G; Chen, Long-Qing; Pan, Xiaoqing
2011-02-09
The polarization of the ferroelectric BiFeO(3) sub-jected to different electrical boundary conditions by heterointerfaces is imaged with atomic resolution using a spherical aberration-corrected transmission electron microscope. Unusual triangular-shaped nanodomains are seen, and their role in providing polarization closure is understood through phase-field simulations. Heterointerfaces are key to the performance of ferroelectric devices, and this first observation of spontaneous vortex nanodomain arrays at ferroelectric heterointerfaces reveals properties unlike the surrounding film including mixed Ising-Néel domain walls, which will affect switching behavior, and a drastic increase of in-plane polarization. The importance of magnetization closure has long been appreciated in multidomain ferromagnetic systems; imaging this analogous effect with atomic resolution at ferroelectric heterointerfaces provides the ability to see device-relevant interface issues. Extension of this technique to visualize domain dynamics is envisioned.
Guilbert, Anne A Y; Zbiri, Mohamed; Jenart, Maud V C; Nielsen, Christian B; Nelson, Jenny
2016-06-16
The molecular dynamics of organic semiconductor blend layers are likely to affect the optoelectronic properties and the performance of devices such as solar cells. We study the dynamics (5-50 ps) of the poly(3-hexylthiophene) (P3HT): phenyl-C61-butyric acid methyl ester (PCBM) blend by time-of-flight quasi-elastic neutron scattering, at temperatures in the range 250-360 K, thus spanning the glass transition temperature region of the polymer and the operation temperature of an OPV device. The behavior of the QENS signal provides evidence for the vitrification of P3HT upon blending, especially above the glass transition temperature, and the plasticization of PCBM by P3HT, both dynamics occurring on the picosecond time scale.
Potentiometric sensors using cotton yarns, carbon nanotubes and polymeric membranes.
Guinovart, Tomàs; Parrilla, Marc; Crespo, Gastón A; Rius, F Xavier; Andrade, Francisco J
2013-09-21
A simple and generalized approach to build electrochemical sensors for wearable devices is presented. Commercial cotton yarns are first turned into electrical conductors through a simple dyeing process using a carbon nanotube ink. These conductive yarns are then partially coated with a suitable polymeric membrane to build ion-selective electrodes. Potentiometric measurements using these yarn-potentiometric sensors are demonstrated. Examples of yarns that can sense pH, K(+) and NH4(+) are presented. In all cases, these sensing yarns show limits of detection and linear ranges that are similar to those obtained with lab-made solid-state ion-selective electrodes. Through the immobilization of these sensors in a band-aid, it is shown that this approach could be easily implemented in a wearable device. Factors affecting the performance of the sensors and future potential applications are discussed.
Transparent Conducting Oxides: Status and Opportunities in Basic Research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coutts, T. J.; Perkins, J. D.; Ginley, D.S.
1999-08-01
In this paper, we begin by discussing the historical background of transparent conducting oxides and then make some general remarks about their typical properties. This is followed by a short discussion of the desired properties for future applications (particularly photovoltaic devices). These are ambitious objectives but they provide targets for future basic research and development. Although it may be possible to obtain these properties in the laboratory, it is vital to ensure that account is taken of industrial perceptions to the development of the next generation of materials. Hence, we spend some time discussing industrial criteria. Next, we discuss keymore » physical properties that determine the macroscopic physical properties that, in turn, affect the performance of devices. Finally, we select several key topics that ought to be included in future basic research programs.« less
Measuring the orbital angular momentum spectrum of an electron beam
Grillo, Vincenzo; Tavabi, Amir H.; Venturi, Federico; Larocque, Hugo; Balboni, Roberto; Gazzadi, Gian Carlo; Frabboni, Stefano; Lu, Peng-Han; Mafakheri, Erfan; Bouchard, Frédéric; Dunin-Borkowski, Rafal E.; Boyd, Robert W.; Lavery, Martin P. J.; Padgett, Miles J.; Karimi, Ebrahim
2017-01-01
Electron waves that carry orbital angular momentum (OAM) are characterized by a quantized and unbounded magnetic dipole moment parallel to their propagation direction. When interacting with magnetic materials, the wavefunctions of such electrons are inherently modified. Such variations therefore motivate the need to analyse electron wavefunctions, especially their wavefronts, to obtain information regarding the material's structure. Here, we propose, design and demonstrate the performance of a device based on nanoscale holograms for measuring an electron's OAM components by spatially separating them. We sort pure and superposed OAM states of electrons with OAM values of between −10 and 10. We employ the device to analyse the OAM spectrum of electrons that have been affected by a micron-scale magnetic dipole, thus establishing that our sorter can be an instrument for nanoscale magnetic spectroscopy. PMID:28537248
Paper-Based Quantification of Male Fertility Potential.
Nosrati, Reza; Gong, Max M; San Gabriel, Maria C; Pedraza, Claudio E; Zini, Armand; Sinton, David
2016-03-01
More than 70 million couples worldwide are affected by infertility, with male-factor infertility accounting for about half of the cases. Semen analysis is critical for determining male fertility potential, but conventional testing is costly and complex. Here, we demonstrate a paper-based microfluidic approach to quantify male fertility potential, simultaneously measuring 3 critical semen parameters in 10 min: live and motile sperm concentrations and sperm motility. The device measures the colorimetric change of yellow tetrazolium dye to purple formazan by the diaphorase flavoprotein enzyme present in metabolically active human sperm to quantify live and motile sperm concentration. Sperm motility was determined as the ratio of motile to live sperm. We assessed the performance of the device by use of clinical semen samples, in parallel with standard clinical approaches. Detection limits of 8.46 and 15.18 million/mL were achieved for live and motile sperm concentrations, respectively. The live and motile sperm concentrations and motility values from our device correlated with those of the standard clinical approaches (R(2) ≥ 0.84). In all cases, our device provided 100% agreement in terms of clinical outcome. The device was also robust and could tolerate conditions of high absolute humidity (22.8 g/m(3)) up to 16 weeks when packaged with desiccant. Our device outperforms existing commercial paper-based assays by quantitatively measuring live and motile sperm concentrations and motility, in only 10 min. This approach is applicable to current clinical practices as well as self-diagnostic applications. © 2015 American Association for Clinical Chemistry.
Design features that affect the maneuverability of wheelchairs and scooters.
Koontz, Alicia M; Brindle, Eric D; Kankipati, Padmaja; Feathers, David; Cooper, Rory A
2010-05-01
To determine the minimum space required for wheeled mobility device users to perform 4 maneuverability tasks and to investigate the impact of selected design attributes on space. Case series. University laboratory, Veterans Affairs research facility, vocational training center, and a national wheelchair sport event. The sample of convenience included manual wheelchair (MWC; n=109), power wheelchair (PWC; n=100), and scooter users (n=14). A mock environment was constructed to create passageways to form an L-turn, 360 degrees -turn in place, and a U-turn with and without a barrier. Passageway openings were increased in 5-cm increments until the user could successfully perform each task without hitting the walls. Structural dimensions of the device and user were collected using an electromechanical probe. Mobility devices were grouped into categories based on design features and compared using 1-way analysis of variance and post hoc pairwise Bonferroni-corrected tests. Minimum passageway widths for the 4 maneuverability tasks. Ultralight MWCs with rear axles posterior to the shoulder had the shortest lengths and required the least amount of space compared with all other types of MWCs (P<.05). Mid-wheel-drive PWCs required the least space for the 360 degrees -turn in place compared with front-wheel-drive and rear-wheel-drive PWCs (P<.01) but performed equally as well as front-wheel-drive models on all other turning tasks. PWCs with seat functions required more space to perform the tasks. Between 10% and 100% of users would not be able to maneuver in spaces that meet current Accessibility Guidelines for Buildings and Facilities specifications. This study provides data that can be used to support wheelchair prescription and home modifications and to update standards to improve the accessibility of public areas.
III-V Compound Detectors for CO2 DIAL Measurements
NASA Technical Reports Server (NTRS)
Refaat, Tamer F.; Abedin, M. Nurul; Sulima, Oleg V.; Ismail, Syed; Singh, Upendra N.
2005-01-01
Profiling of atmospheric carbon dioxide (CO2) is important for understanding the natural carbon cycle on Earth and its influence on global warming and climate change. Differential absorption lidar is a powerful remote sensing technique used for profiling and monitoring atmospheric constituents. Recently there has been an interest to apply this technique, at the 2 m wavelength, for investigating atmospheric CO2. This drives the need for high quality detectors at this wavelength. Although 2 m detectors are commercially available, the quest for a better detector is still on. The detector performance, regarding quantum efficiency, gain and associated noise, affects the DIAL signal-to-noise ratio and background signal, thereby influencing the instrument sensitivity and dynamic range. Detectors based on the III-V based compound materials shows a strong potential for such application. In this paper the detector requirements for a long range CO2 DIAL profiles will be discussed. These requirements were compared to newly developed III-V compound infrared detectors. The performance of ternary InGaSb pn junction devices will be presented using different substrates, as well as quaternary InGaAsSb npn structure. The performance study was based on experimental characterization of the devices dark current, spectral response, gain and noise. The final results are compared to the current state-of-the-art InGaAs technology. Npn phototransistor structure showed the best performance, regarding the internal gain and therefore the device signal-to-noise ratio. 2-micrometers detectivity as high as 3.9 x 10(exp 11) cmHz(sup 1/2)/W was obtained at a temperature of -20 C and 4 V bias voltage. This corresponds to a responsivity of 2650 A/W with about 60% quantum efficiency.
Performance of correlation receivers in the presence of impulse noise.
NASA Technical Reports Server (NTRS)
Moore, J. D.; Houts, R. C.
1972-01-01
An impulse noise model, which assumes that each noise burst contains a randomly weighted version of a basic waveform, is used to derive the performance equations for a correlation receiver. The expected number of bit errors per noise burst is expressed as a function of the average signal energy, signal-set correlation coefficient, bit time, noise-weighting-factor variance and probability density function, and a time range function which depends on the crosscorrelation of the signal-set basis functions and the noise waveform. Unlike the performance results for additive white Gaussian noise, it is shown that the error performance for impulse noise is affected by the choice of signal-set basis function, and that Orthogonal signaling is not equivalent to On-Off signaling with the same average energy. Furthermore, it is demonstrated that the correlation-receiver error performance can be improved by inserting a properly specified nonlinear device prior to the receiver input.
Safety of an intra-oral hearing device utilizing a split-mouth research design.
Miller, Ross; Hujoel, Philippe; Murray, Michael; Popelka, Gerald R
2011-01-01
The auditory deficits of Single Sided Deafness (SSD) can be treated effectively with a novel device, SoundBite, that delivers sound by applying imperceptible vibratory signals to the teeth (hereafter referred to as an intra-oral hearing device). The intra-oral hearing device is placed around two maxillary teeth and is similar to a small partial denture or retainer. The goal of this study was to report how this removable hearing device affects the oral structures. Twenty-two SSD patients wearing an intra-oral hearing device were enrolled in a prospective study for six months. Differences (delta) between the device-anchoring teeth and the equivalent contralateral non-device teeth were evaluated with four dental parameters using a paired t-test. Hearing thresholds were evaluated as a function of alveolar bone support using linear regression. Compared to the non-device teeth, the hearing device teeth did not exhibit any increased recession (delta = 0.1 mm, p-value = 0.48), increased pocket depth (delta = 0.0 mm, p-value = 0.48), increased root resorption (delta = 4%, p-value = 0.43), or increased alveolar bone loss (delta = 0.0 %, p-value = 0.43). There was no association between the amount of alveolar support and hearing thresholds (delta = 0.2, p-value = 0.34). The intra-oral component of the hearing device did not adversely affect the dental structures of the subjects in this trial.
Thermoelectric Air/Soil Energy-Harvesting Device
NASA Technical Reports Server (NTRS)
Snyder, Jeffrey; Fleurial, Jean-Pierre; Lawrence, Eric
2005-01-01
A proposed thermoelectric device would exploit natural temperature differences between air and soil to harvest small amounts of electric energy. Because the air/soil temperature difference fluctuates between nighttime and daytime, it is almost never zero, and so there is almost always some energy available for harvesting. Unlike photovoltaic cells, the proposed device could operate in the absence of sunlight. Unlike a Stirling engine, which could be designed to extract energy from the air/soil temperature difference, the proposed device would contain no moving parts. The main attractive feature of the proposed device would be high reliability. In a typical application, this device would be used for low-power charging of a battery that would, in turn, supply high power at brief, infrequent intervals for operating an instrumentation package containing sensors and communication circuits. The device (see figure) would include a heat exchanger buried in soil and connected to a heat pipe extending up to a short distance above the ground surface. A thermoelectric microgenerator (TEMG) would be mounted on top of the heat pipe. The TEMG could be of an advanced type, now under development, that could maintain high (relative to prior thermoelectric generators) power densities at small temperature differentials. A heat exchanger exposed to the air would be mounted on top of the TEMG. It would not matter whether the air was warmer than the soil or the soil warmer than the air: as long as there was a nonzero temperature difference, heat would flow through the device and electricity would be generated. A study of factors that could affect the design and operation of the device has been performed. These factors include the thermal conductances of the soil, the components of the device, the contacts between the components of the device, and the interfaces between the heat exchangers and their environments. The study included experiments that were performed on a model of the device to demonstrate feasibility. Because a TEMG suitable for this device was not available, a brass dummy component having a known thermal conductance of 1.68 W/K was substituted for the TEMG in the models to enable measurement of heat flows. The model included a water-based heat pipe 30 in. (76.2 cm) long and 1 in. (2.54 cm) in diameter, wrapped with polyethylene insulation to reduce radial heat flow. Several different side heat exchangers were tested. On the basis of the measurements, it was predicted that if a prototype of the device were equipped with a TEMG, daily temperature fluctuations would cause its output power to fluctuate between 0 and about 0.1 mW, peaking to 0.35 mW during early afternoon.
High Sensitive pH Sensor Based on AlInN/GaN Heterostructure Transistor.
Dong, Yan; Son, Dong-Hyeok; Dai, Quan; Lee, Jun-Hyeok; Won, Chul-Ho; Kim, Jeong-Gil; Chen, Dunjun; Lee, Jung-Hee; Lu, Hai; Zhang, Rong; Zheng, Youdou
2018-04-24
The AlInN/GaN high-electron-mobility-transistor (HEMT) indicates better performances compared with the traditional AlGaN/GaN HEMTs. The present work investigated the pH sensor functionality of an analogous HEMT AlInN/GaN device with an open gate. It was shown that the Al 0.83 In 0.17 N/GaN device demonstrates excellent pH sense functionality in aqueous solutions, exhibiting higher sensitivity (−30.83 μA/pH for AlInN/GaN and −4.6 μA/pH for AlGaN/GaN) and a faster response time, lower degradation and good stability with respect to the AlGaN/GaN device, which is attributed to higher two-dimensional electron gas (2DEG) density and a thinner barrier layer in Al 0.83 In 0.17 N/GaN owning to lattice matching. On the other hand, the open gate geometry was found to affect the pH sensitivity obviously. Properly increasing the width and shortening the length of the open gate area could enhance the sensitivity. However, when the open gate width is too larger or too small, the pH sensitivity would be suppressed conversely. Designing an optimal ratio of the width to the length is important for achieving high sensitivity. This work suggests that the AlInN/GaN-based 2DEG carrier modulated devices would be good candidates for high-performance pH sensors and other related applications.
Loss reduction in silicon nanophotonic waveguide micro-bends through etch profile improvement
NASA Astrophysics Data System (ADS)
Selvaraja, Shankar Kumar; Bogaerts, Wim; Van Thourhout, Dries
2011-04-01
Single mode silicon photonic wire waveguides allow low-loss sharp micro-bends, which enables compact photonic devices and circuits. The circuit compactness is achieved at the cost of loss induced by micro-bends, which can seriously affect the device performance. The bend loss strongly depends on the bend radius, polarization, waveguide dimension and profile. In this paper, we present the effect of waveguide profile on the bend loss. We present waveguide profile improvement with optimized etch chemistry and the role of etch chemistry in adapting the etch profile of silicon is investigated. We experimentally demonstrate that by making the waveguide sidewalls vertical, the bend loss can be reduced up to 25% without affecting the propagation loss of the photonic wires. The bend loss of a 2 μm bend has been reduced from 0.039dB/90° bend to 0.028dB/90° bend by changing the sidewall angle from 81° to 90°, respectively. The propagation loss of 2.7 ± 0.1dB/cm and 3 ± 0.09dB/cm was observed for sloped and vertical photonic wires respectively was obtained.
The effect of mechanical loads on the degradation of aliphatic biodegradable polyesters.
Li, Ying; Chu, Zhaowei; Li, Xiaoming; Ding, Xili; Guo, Meng; Zhao, Haoran; Yao, Jie; Wang, Lizhen; Cai, Qiang; Fan, Yubo
2017-06-01
Aliphatic biodegradable polyesters have been the most widely used synthetic polymers for developing biodegradable devices as alternatives for the currently used permanent medical devices. The performances during biodegradation process play crucial roles for final realization of their functions. Because physiological and biochemical environment in vivo significantly affects biodegradation process, large numbers of studies on effects of mechanical loads on the degradation of aliphatic biodegradable polyesters have been launched during last decades. In this review article, we discussed the mechanism of biodegradation and several different mechanical loads that have been reported to affect the biodegradation process. Other physiological and biochemical factors related to mechanical loads were also discussed. The mechanical load could change the conformational strain energy and morphology to weaken the stability of the polymer. Besides, the load and pattern could accelerate the loss of intrinsic mechanical properties of polymers. This indicated that investigations into effects of mechanical loads on the degradation should be indispensable. More combination condition of mechanical loads and multiple factors should be considered in order to keep the degradation rate controllable and evaluate the degradation process in vivo accurately. Only then can the degradable devise achieve the desired effects and further expand the special applications of aliphatic biodegradable polyesters.
Long-wave plasma radiofrequency ablation for treatment of xanthelasma palpebrarum.
Baroni, Adone
2018-03-01
Xanthelasma palpebrarum is the most common type of xanthoma affecting the eyelids. It is characterized by asymptomatic soft yellowish macules, papules, or plaques over the upper and lower eyelids. Many treatments are available for management of xanthelasma palpebrarum, the most commonly used include surgical excision, ablative CO 2 or erbium lasers, nonablative Q-switched Nd:YAG laser, trichloroacetic acid peeling, and radiofrequency ablation. This study aims to evaluate the effectiveness of RF ablation in the treatment of xanthelasma palpebrarum, with D.A.S. Medical portable device (Technolux, Italia), a radiofrequency tool working with long-wave plasma energy and without anesthesia. Twenty patients, 15 female and 5 male, affected by xanthelasma palpebrarum, were enrolled for long-wave plasma radiofrequency ablation treatment. The treatment consisted of 3/4 sessions that were carried out at intervals of 30 days. Treatments were well tolerated by all patients with no adverse effects and optimal aesthetic results. The procedure is very fast and can be performed without anesthesia because of the low and tolerable pain stimulation. Long-wave plasma radiofrequency ablation is an effective option for treatment of xanthelasma palpebrarum and adds an additional tool to the increasing list of medical devices for aesthetic treatments. © 2018 Wiley Periodicals, Inc.
Taaffe, Margaret; Fischer, Evelyn; Baranowski, Andreas; Majunke, Nicolas; Heinisch, Corinna; Leetz, Michaela; Hein, Ralph; Bayard, Yves; Büscheck, Franziska; Reschke, Madlen; Hoffmann, Ilona; Wunderlich, Nina; Wilson, Neil; Sievert, Horst
2008-05-01
This randomized trial compared procedural complications and 30-day clinical outcomes of 3 patent foramen ovale (PFO) closure devices (Amplatzer, Helex, and CardioSEAL-STARflex). It examined 660 patients (361 men, 299 women, mean age 49.3+/-1.9 years), with 220 patients per group. All patients had a history of paradoxical embolism. All PFO closures were successful technically. Exchange of devices for others was most frequently required for the Helex occluder (7 of 220) and 2 of 220 in either of the other groups. Three device embolizations in the Helex group were retrieved and replaced successfully. One patient with a Helex occluder developed a transient ischemic attack and recovered without treatment. A hemopericardium in that group was punctured without affecting the device. One tamponade in the Amplatzer group required surgical device explantation. In 8 of 660 patients in the CardioSEAL-STARflex group, thrombi resolved after anticoagulation. Sixteen patients (11 in the CardioSEAL-STARflex group, 3 in the Amplatzer group, and 2 in the Helex group) had episodes of atrial fibrillation. PFOs were closed completely in 143 of 220 patients (65%) in the Amplatzer group, 116 of 220 patients (52.7%) in the Helex group, and 137 of 220 patients (62.3%) in the CardioSEAL-STARflex group at 30 days with significant differences between the Helex and Amplatzer occluders (p=0.0005) and the Helex and CardioSEAL-STARflex occluders (p=0.0003). PFO closure can be performed safely with each device. In conclusion, the Helex occluder embolized more frequently. Device thrombus formation and paroxysmal atrial fibrillation were more common with the CardioSEAL-STARflex occluder.
Investigations on the role of mixed-solvent for improved efficiency in perovskite solar cell
NASA Astrophysics Data System (ADS)
Singh, Ranbir; Suranagi, Sanjaykumar R.; Kumar, Manish; Shukla, Vivek Kumar
2017-12-01
The morphology of the spin-coated photoactive layer is one of the major factors affecting the performance of perovskite solar cells. In this work, we have employed a mixed-solvent strategy to obtain a high quality MAPbI3 (MA = CH3NH3) perovskite film, without pinholes and reduced grain boundaries. Perovskite films formed with single and mixed-solvents are systematically characterized for their optical, structural, and morphological properties using UV-vis absorption, photoluminescence (PL), X-ray diffraction (XRD), atomic force microscopy (AFM), and scanning electron microscopy (SEM) tools. The power conversion efficiency (PCE) of the devices fabricated using the mixed-solvent showed better performance than the devices made using the single solvent. The best-optimized mixed-solvent perovskite film exhibited a PCE of 15.2% with uniform film coverage on the substrate, better charge generation, and a high hole mobility of 1.16 × 10-4cm2/V s. The disparities in photovoltaic properties have been analyzed with the intensity dependent current density-voltage (J-V), transient photovoltage (TPV), and relationship between photocurrent (Jph) and effective voltage (Veff).
Morón, María José; Luque, Rafael; Casilari, Eduardo
2014-01-01
This paper evaluates and characterizes the technical performance of medical wireless personal area networks (WPANs) that are based on smartphones. For this purpose, a prototype of a health telemonitoring system is presented. The prototype incorporates a commercial Android smartphone, which acts as a relay point, or “gateway”, between a set of wireless medical sensors and a data server. Additionally, the paper investigates if the conventional capabilities of current commercial smartphones can be affected by their use as gateways or “Holters” in health monitoring applications. Specifically, the profiling has focused on the CPU and power consumption of the mobile devices. These metrics have been measured under several test conditions modifying the smartphone model, the type of sensors connected to the WPAN, the employed Bluetooth profile (SPP (serial port profile) or HDP (health device profile)), the use of other peripherals, such as a GPS receiver, the impact of the use of the Wi-Fi interface or the employed method to encode and forward the data that are collected from the sensors. PMID:24451456
Morón, María José; Luque, Rafael; Casilari, Eduardo
2014-01-02
This paper evaluates and characterizes the technical performance of medical wireless personal area networks (WPANs) that are based on smartphones. For this purpose,a prototype of a health telemonitoring system is presented. The prototype incorporates a commercial Android smartphone, which acts as a relay point, or "gateway", between a set of wireless medical sensors and a data server. Additionally, the paper investigates if the conventional capabilities of current commercial smartphones can be affected by their use as gateways or "Holters" in health monitoring applications. Specifically, the profiling has focused on the CPU and power consumption of the mobile devices. These metrics have been measured under several test conditions modifying the smartphone model, the type of sensors connected to the WPAN, the employed Bluetooth profile (SPP (serial port profile) orHDP (health device profile)), the use of other peripherals, such as a GPS receiver, the impact of the use of the Wi-Fi interface or the employed method to encode and forward the data that are collected from the sensors.
III-Nitride Blue Laser Diode with Photoelectrochemically Etched Current Aperture
NASA Astrophysics Data System (ADS)
Megalini, Ludovico
Group III-nitride is a remarkable material system to make highly efficient and high-power optoelectronics and electronic devices because of the unique electrical, physical, chemical and structural properties it offers. In particular, InGaN-based blue Laser Diodes (LDs) have been successfully employed in a variety of applications ranging from biomedical and military devices to scientific instrumentation and consumer electronics. Recently their use in highly efficient Solid State Lighting (SSL) has been proposed because of their superior beam quality and higher efficiency at high input power density. Tremendous advances in research of GaN semi-polar and non-polar crystallographic planes have led both LEDs and LDs grown on these non-basal planes to rival with, and with the promise to outperform, their equivalent c-plane counterparts. However, still many issues need to be addressed, both related to material growth and device fabrication, including a lack of conventional wet etching techniques. GaN and its alloys with InN and AlN have proven resistant essentially to all known standard wet etching techniques, and the predominant etching methods rely on chlorine-based dry etching (RIE). These introduce sub-surface damage which can degrade the electrical properties of the epitaxial structure and reduce the reliability and lifetime of the final device. Such reasons and the limited effectiveness of passivation techniques have so far suggested to etch the LD ridges before the active region, although it is well-known that this can badly affect the device performance, especially in narrow stripe width LDs, because the gain guiding obtained in the planar configuration is weak and the low index step and high lateral current leakage result in devices with threshold current density higher than devices whose ridge is etched beyond the active region. Moreover, undercut etching of III-nitride layers has proven even more challenging, with limitations in control of the lateral etch distance. In this dissertation it is presented the first nitride blue edge emitting LD with a photoelectrochemical etched current aperture (CA-LD) into the device active region. Photoelectrochemical etching (PECE) has emerged as a powerful wet etching technique for III-nitride compounds. Beyond the advantages of wet etching technique, PECE offers bandgap selectivity, which is particularly desirable because it allows more freedom in designing new and advanced devices with higher performances. In the first part of this thesis a review of PECE is presented, and it is shown how it can be used to achieve a selective and controllable deep undercut of the active region of LEDs and LDs, in particular the selective PECE of MQW active region of (10-10) m-plane and (20-2-1) plane structures is reported. In the second part of this thesis, the fabrication flow process of the CA-LD is described. The performance of these devices is compared with that of shallow etched ridge LDs with a nominally identical epitaxial structure and active region width and it is experimentally shown that the CA-LD design has superior performance. CW operation of a (20-2-1) CA-LD with a 1.5 microm wide active region is demonstrated. Finally, in the third and last part of this thesis, the CA-LD performance is discussed in more details, in particular, an analysis of optical scattering losses caused by the rough edges of the remnant PEC etched active region is presented.
Validity and reliability of a new ankle dorsiflexion measurement device.
Gatt, Alfred; Chockalingam, Nachiappan
2013-08-01
The assessment of the maximum ankle dorsiflexion angle is an important clinical examination procedure. Evidence shows that the traditional goniometer is highly unreliable, and various designs of goniometers to measure the maximum ankle dorsiflexion angle rely on the application of a known force to obtain reliable results. Hence, an innovative ankle dorsiflexion measurement device was designed to make this measurement more reliable by holding the foot in a selected posture without the application of a known moment. To report on the comprehensive validity and reliability testing carried out on the new device. Following validity testing, four different trials to test reliability of the ankle dorsiflexion measurement device were performed. These trials included inter-rater and intra-rater testings with a controlled moment, intra-rater reliability testing with knees flexed and extended without a controlled moment, intra-rater testing with a patient population, and inter-rater reliability testing between four raters of varying experience without controlling moment. All raters were blinded. A series of trials to test intra-rater and inter-rater reliabilities. Intra-rater reliability intraclass correlation coefficient was 0.98 and inter-rater reliability intraclass correlation coefficient (2,1) was 0.953 with a controlled moment. With uncontrolled moment, very high reliability for intra-tester was also achieved (intraclass correlation coefficient = 0.94 with knees extended and intraclass correlation coefficient = 0.95 with knees flexed). For the trial investigating test-retest reliability with actual patients, intraclass correlation coefficient of 0.99 was obtained. In the trial investigating four different raters with uncontrolled moment, intraclass correlation coefficient of 0.91 was achieved. The new ankle dorsiflexion measurement device is a valid and reliable device for measuring ankle dorsiflexion in both healthy subjects and patients, with both controlled and uncontrolled moments, even by multiple raters of varying experience when the foot is dorsiflexed to its end of range of motion. An ankle dorsiflexion measuring device has been designed to increase the reliability of ankle dorsiflexion measurement and replace the traditional goniometer. While the majority of similar devices rely on application of a known moment to perform this measurement, it has been shown that this is not required with the new ankle dorsiflexion measurement device and, rather, foot posture should be taken into consideration as this affects the maximum ankle dorsiflexion angle.
NASA Astrophysics Data System (ADS)
Pollard, Thomas B
Recent advances in microbiology, computational capabilities, and microelectromechanical-system fabrication techniques permit modeling, design, and fabrication of low-cost, miniature, sensitive and selective liquid-phase sensors and lab-on-a-chip systems. Such devices are expected to replace expensive, time-consuming, and bulky laboratory-based testing equipment. Potential applications for devices include: fluid characterization for material science and industry; chemical analysis in medicine and pharmacology; study of biological processes; food analysis; chemical kinetics analysis; and environmental monitoring. When combined with liquid-phase packaging, sensors based on surface-acoustic-wave (SAW) technology are considered strong candidates. For this reason such devices are focused on in this work; emphasis placed on device modeling and packaging for liquid-phase operation. Regarding modeling, topics considered include mode excitation efficiency of transducers; mode sensitivity based on guiding structure materials/geometries; and use of new piezoelectric materials. On packaging, topics considered include package interfacing with SAW devices, and minimization of packaging effects on device performance. In this work novel numerical models are theoretically developed and implemented to study propagation and transduction characteristics of sensor designs using wave/constitutive equations, Green's functions, and boundary/finite element methods. Using developed simulation tools that consider finite-thickness of all device electrodes, transduction efficiency for SAW transducers with neighboring uniform or periodic guiding electrodes is reported for the first time. Results indicate finite electrode thickness strongly affects efficiency. Using dense electrodes, efficiency is shown to approach 92% and 100% for uniform and periodic electrode guiding, respectively; yielding improved sensor detection limits. A numerical sensitivity analysis is presented targeting viscosity using uniform-electrode and shear-horizontal mode configurations on potassium-niobate, langasite, and quartz substrates. Optimum configurations are determined yielding maximum sensitivity. Results show mode propagation-loss and sensitivity to viscosity are correlated by a factor independent of substrate material. The analysis is useful for designing devices meeting sensitivity and signal level requirements. A novel, rapid and precise microfluidic chamber alignment/bonding method was developed for SAW platforms. The package is shown to have little effect on device performance and permits simple macrofluidic interfacing. Lastly, prototypes were designed, fabricated, and tested for viscosity and biosensor applications; results show ability to detect as low as 1% glycerol in water and surface-bound DNA crosslinking.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woo, Leta Yar-Li; Glass, Robert Scott; Fitzpatrick, Joseph Jay
2018-01-02
A device for signal processing. The device includes a signal generator, a signal detector, and a processor. The signal generator generates an original waveform. The signal detector detects an affected waveform. The processor is coupled to the signal detector. The processor receives the affected waveform from the signal detector. The processor also compares at least one portion of the affected waveform with the original waveform. The processor also determines a difference between the affected waveform and the original waveform. The processor also determines a value corresponding to a unique portion of the determined difference between the original and affected waveforms.more » The processor also outputs the determined value.« less
Zhang, Feng; Xu, Yuetong; Chou, Jarong
2016-01-01
The service of sensor device in Emerging Sensor Networks (ESNs) is the extension of traditional Web services. Through the sensor network, the service of sensor device can communicate directly with the entity in the geographic environment, and even impact the geographic entity directly. The interaction between the sensor device in ESNs and geographic environment is very complex, and the interaction modeling is a challenging problem. This paper proposed a novel Petri Nets-based modeling method for the interaction between the sensor device and the geographic environment. The feature of the sensor device service in ESNs is more easily affected by the geographic environment than the traditional Web service. Therefore, the response time, the fault-tolerant ability and the resource consumption become important factors in the performance of the whole sensor application system. Thus, this paper classified IoT services as Sensing services and Controlling services according to the interaction between IoT service and geographic entity, and classified GIS services as data services and processing services. Then, this paper designed and analyzed service algebra and Colored Petri Nets model to modeling the geo-feature, IoT service, GIS service and the interaction process between the sensor and the geographic enviroment. At last, the modeling process is discussed by examples. PMID:27681730
NASA Astrophysics Data System (ADS)
Huang, Jinhua; Lu, Yuehui; Wu, Wenxuan; Li, Jia; Zhang, Xianpeng; Zhu, Chaoting; Yang, Ye; Xu, Feng; Song, Weijie
2017-11-01
Various flexible transparent conducting electrodes (FTCEs) have been studied for promising applications in flexible optoelectronic devices, but there are still challenges in achieving higher transparency and conductivity, lower thickness, better mechanical flexibility, and lower preparation temperatures. In this work, we prepared a sub-40 nm Ag(9 nm)/ZnO(30 nm) FTCE at room temperature, where each layer played a relatively independent role in the tailoring of the optoelectronic properties. A continuous and smooth 9-nm Ag thin film was grown on amino-functionalized glass and polyethylene terephthalate (PET) substrates to provide good conductivity. A 30-nm ZnO cladding, as an antireflection layer, further improved the transmittance while hardly affecting the conductivity. The room-temperature grown sub-40 nm Ag/ZnO thin films on PET substrate exhibited a transmittance of 88.6% at 550 nm and a sheet resistance of 7.6 Ω.sq-1, which were superior to those of the commercial ITO. The facile preparation benefits the integration of FTCEs into various flexible optoelectronic devices, where the excellent performance of the sub-40 nm Ag/ZnO FTCEs in a flexible polymer dispersed liquid crystal device was demonstrated. Sub-40 nm Ag/ZnO FTCEs that have the characteristics of simple structure, room-temperature preparation, and easily tailored optoelectronic properties would provide flexible optoelectronic devices with more degrees of freedom.
Development, validation and application of a device to measure e-cigarette users’ puffing topography
Cunningham, Anthony; Slayford, Sandra; Vas, Carl; Gee, Jodie; Costigan, Sandra; Prasad, Krishna
2016-01-01
With the rapidly rising popularity and substantial evolution of electronic cigarettes (e-cigarettes) in the past 5–6 years, how these devices are used by vapers and consumers’ exposure to aerosol emissions need to be understood. We used puffing topography to measure directly product use. We adapted a cigarette puffing topography device for use with e-cigarettes. We performed validation using air and e-cigarette aerosol under multiple regimes. Consumer puffing topography was measured for 60 vapers provided with rechargeable “cig-a-like” or larger button-activated e-cigarettes, to use ad-libitum in two sessions. Under all regimes, air puff volumes were within 1 mL of the target and aerosol volumes within 5 mL for all device types, serving to validate the device. Vapers’ mean puff durations (2.0 s and 2.2 s) were similar with both types of e-cigarette, but mean puff volumes (52.2 mL and 83.0 mL) and mean inter-puff intervals (23.2 s and 29.3 s) differed significantly. The differing data show that product characteristics influence puffing topography and, therefore, the results obtained from a given e-cigarette might not read across to other products. Understanding the factors that affect puffing topography will be important for standardising testing protocols for e-cigarette emissions. PMID:27721496
NASA Astrophysics Data System (ADS)
Zhu, Jianxiong; Wang, Hai; Zhu, Yali
2018-01-01
This work presents the design, fabrication, and measurement of a piezoresistive device with a carbon black (CB) particle network in a highly flexible silicone rubber for large deformation and wide range strain sensing. The piezoresistive composite film was fabricated with a mixture of silicone rubber and CB filler particles. The test results showed that the CB particle network in the silicone rubber strongly affected the resistance of the device during the process of drawing and its recovery. We found that the 50% volume ratio of CB filler particles showed a lower relative resistance than the 33.3% volume ratio of CB filler particles, but with an advantage of good resistance recovery stability and a smaller perturbation error (smaller changed resistance) during the periodic back and forth linear motor test. With both having a 50% volume ratio of CB filler particles and a 33.3% volume ratio of CB filler particles, one can reach up to 200% strain with resistances 18 kΩ and 110 kΩ, respectively. We also found that the relative resistance increased in an approximately linear relationship corresponding to the value of step-increased instantaneous length for the reported device. Moreover, an application test through hand drawing was used to demonstrate the piezoresistive performance of the device, which showed that the reported device was capable of measuring the instantaneous length with large deformation.
Cunningham, Anthony; Slayford, Sandra; Vas, Carl; Gee, Jodie; Costigan, Sandra; Prasad, Krishna
2016-10-10
With the rapidly rising popularity and substantial evolution of electronic cigarettes (e-cigarettes) in the past 5-6 years, how these devices are used by vapers and consumers' exposure to aerosol emissions need to be understood. We used puffing topography to measure directly product use. We adapted a cigarette puffing topography device for use with e-cigarettes. We performed validation using air and e-cigarette aerosol under multiple regimes. Consumer puffing topography was measured for 60 vapers provided with rechargeable "cig-a-like" or larger button-activated e-cigarettes, to use ad-libitum in two sessions. Under all regimes, air puff volumes were within 1 mL of the target and aerosol volumes within 5 mL for all device types, serving to validate the device. Vapers' mean puff durations (2.0 s and 2.2 s) were similar with both types of e-cigarette, but mean puff volumes (52.2 mL and 83.0 mL) and mean inter-puff intervals (23.2 s and 29.3 s) differed significantly. The differing data show that product characteristics influence puffing topography and, therefore, the results obtained from a given e-cigarette might not read across to other products. Understanding the factors that affect puffing topography will be important for standardising testing protocols for e-cigarette emissions.
Saboury, Aboulfazl; Sadr, Seyed Jalil; Fayaz, Ali; Mahshid, Minoo
2013-01-01
Objective: High variability in delivering the target torque is reported for friction-style mechanical torque limiting devices (F-S MTLDs). The effect of aging (number of use) on the accuracy of these devices is not clear. The purpose of this study was to assess the effect of aging on the accuracy (±10% of the target torque) of F-S MTLDs. Materials and Methods: Fifteen new F-S MTLDs and their appropriate drivers from three different implant manufacturers (Astra Tech, Biohorizon and Dr Idhe), five for each type, were selected. The procedure of peak torque measurement was performed in ten sequences before and after aging. In each sequence, ten repetitions of peak torque values were registered for the aging procedure. To measure the output of each device, a Tohnichi torque gauge was used. Results: Before aging, peak torque measurements of all the devices tested in this study falled within 10% of their preset target values. After aging, a significant difference was seen between raw error values of three groups of MTLDs (P<0.05). More than 50% of all peak torque measurements demonstrated more than 10% difference from their torque values after aging. Conclusion: Within the limitation of this study, aging as an independent factor affects the accuracy of F-S MTLDs. Astra Tech MTLDs presented the most consistent torque output for 25 Ncm target torque. PMID:23724202
Study on initiative vibration absorbing technology of optics in strong disturbed environment
NASA Astrophysics Data System (ADS)
Jia, Si-nan; Xiong, Mu-di; Zou, Xiao-jie
2007-12-01
Strong disturbed environment is apt to cause irregular vibration, which seriously affects optical collimation. To improve the performance of laser beam, three-point dynamic vibration absorbing method is proposed, and laser beam initiative vibration absorbing system is designed. The maladjustment signal is detected by position sensitive device (PSD), three groups of PZT are driven to adjust optical element in real-time, so the performance of output-beam is improved. The coupling model of the system is presented. Multivariable adaptive closed-loop decoupling arithmetic is used to design three-input-three-output decoupling controller, so that high precision dynamic adjusting is realized. Experiments indicate that the system has good shock absorbing efficiency.
Noiseless optical amplification in quasi-phase-matched bulk lithium niobate
NASA Astrophysics Data System (ADS)
Lovering, D. J.; Levenson, J. A.; Vidakovic, P.; Webjörn, J.; Russell, P. St. J.
1996-09-01
An optical parametric amplifier (OPA) has been demonstrated in bulk, periodically poled lithium niobate and is shown to operate with a noise figure well below the classical limit. In contrast to conventional OPA's, this device uses quasi-phase matching to provide the coupling between the pump and the signal. Comparison of the measured performance with that of a theoretical model reveals that the main intrinsic contribution to the output noise is due to spatial and temporal mode mixing, which arises as a consequence of tight focusing of the incident beams. Factors that affect the performance of this amplifier are identified theoretically and their relative importance investigated for both amplification and squeezing.
Effect of display size on visual attention.
Chen, I-Ping; Liao, Chia-Ning; Yeh, Shih-Hao
2011-06-01
Attention plays an important role in the design of human-machine interfaces. However, current knowledge about attention is largely based on data obtained when using devices of moderate display size. With advancement in display technology comes the need for understanding attention behavior over a wider range of viewing sizes. The effect of display size on test participants' visual search performance was studied. The participants (N = 12) performed two types of visual search tasks, that is, parallel and serial search, under three display-size conditions (16 degrees, 32 degrees, and 60 degrees). Serial, but not parallel, search was affected by display size. In the serial task, mean reaction time for detecting a target increased with the display size.
Long, Guankui; Wu, Bo; Yang, Xuan; Kan, Bin; Zhou, Ye-Cheng; Chen, Li-Chuan; Wan, Xiangjian; Zhang, Hao-Li; Sum, Tze Chien; Chen, Yongsheng
2015-09-30
Both solution-processed polymers and small molecule based solar cells have achieved PCEs over 9% with the conventional device structure. However, for the practical applications of photovoltaic technology, further enhancement of both device performance and stability are urgently required, particularly for the inverted structure devices, since this architecture will probably be most promising for the possible coming commercialization. In this work, we have fabricated both conventional and inverted structure devices using the same small molecular donor/acceptor materials and compared the performance of both device structures, and found that the inverted structure based device gave significantly improved performance, the highest PCE so far for inverted structure based device using small molecules as the donor. Furthermore, the inverted device shows a remarkable stability with almost no obvious degradation after three months. Systematic device physics and charge generation dynamics studies, including optical simulation, light-intensity-dependent current-voltage experiments, photocurrent density-effective voltage analyses, transient absorption measurements, and electrical simulations, indicate that the significantly enhanced performance using inverted device is ascribed to the increasing of Jsc compared to the conventional device, which in turn is mainly attributed to the increased absorption of photons in the active layers, rather than the reduced nongeminate recombination.
Impact of various operating modes on performance and emission parameters of small heat source
NASA Astrophysics Data System (ADS)
Vician, Peter; Holubčík, Michal; Palacka, Matej; Jandačka, Jozef
2016-06-01
Thesis deals with the measurement of performance and emission parameters of small heat source for combustion of biomass in each of its operating modes. As the heat source was used pellet boiler with an output of 18 kW. The work includes design of experimental device for measuring the impact of changes in air supply and method for controlling the power and emission parameters of heat sources for combustion of woody biomass. The work describes the main factors that affect the combustion process and analyze the measurements of emissions at the heat source. The results of experiment demonstrate the values of performance and emissions parameters for the different operating modes of the boiler, which serve as a decisive factor in choosing the appropriate mode.
Development and testing of an artificial arterial and venous pulse oximeter.
Cloete, G; Fourie, P R; Scheffer, C
2013-01-01
The monitoring of patients healthcare is of a prime importance to ensure their efficient and effective treatment. Monitoring blood oxygen saturation is a field which has grown significantly in recent times and more specifically in tissues affected by diseases or conditions that may negatively affect the function of the tissue. This study involved the development and testing of a highly sensitive non-invasive blood oxygen saturation monitoring device. A device that can be used to continuously monitor the condition of tissue affected by diseases which affect the blood flow through the tissue, and the oxygen usage in tissue. The device's system was designed to specifically monitor occluded tissue which has low oxygen saturations and low perfusion. Although with limitted validation the system was unable to accurately measure the venous oxygenation specifically, but it was able to measure the mixed oxygen saturation. With further research it would be possible to validate the system for measuring both the arterial and venous oxygen saturations.
Sub-Shot Noise Power Source for Microelectronics
NASA Technical Reports Server (NTRS)
Strekalov, Dmitry V.; Yu, Nan; Mansour, Kamjou
2011-01-01
Low-current, high-impedance microelectronic devices can be affected by electric current shot noise more than they are affected by Nyquist noise, even at room temperature. An approach to implementing a sub-shot noise current source for powering such devices is based on direct conversion of amplitude-squeezed light to photocurrent. The phenomenon of optical squeezing allows for the optical measurements below the fundamental shot noise limit, which would be impossible in the domain of classical optics. This becomes possible by affecting the statistical properties of photons in an optical mode, which can be considered as a case of information encoding. Once encoded, the information describing the photon (or any other elementary excitations) statistics can be also transmitted. In fact, it is such information transduction from optics to an electronics circuit, via photoelectric effect, that has allowed the observation of the optical squeezing. It is very difficult, if not technically impossible, to directly measure the statistical distribution of optical photons except at extremely low light level. The photoelectric current, on the other hand, can be easily analyzed using RF spectrum analyzers. Once it was observed that the photocurrent noise generated by a tested light source in question is below the shot noise limit (e.g. produced by a coherent light beam), it was concluded that the light source in question possess the property of amplitude squeezing. The main novelty of this technology is to turn this well-known information transduction approach around. Instead of studying the statistical property of an optical mode by measuring the photoelectron statistics, an amplitude-squeezed light source and a high-efficiency linear photodiode are used to generate photocurrent with sub-Poissonian electron statistics. By powering microelectronic devices with this current source, their performance can be improved, especially their noise parameters. Therefore, a room-temperature sub-shot noise current source can be built that will be beneficial for a very broad range of low-power, low-noise electronic instruments and applications, both cryogenic and room-temperature. Taking advantage of recent demonstrations of the squeezed light sources based on optical micro-disks, this sub-shot noise current source can be made compatible with the size/power requirements specific of the electronic devices it will support.
Fischer, Paul; Knauer, Stefan; Marx, Gerrit; Schweikhard, Lutz
2018-01-01
The recently introduced method of ion separation by transversal ejection of unwanted species in electrostatic ion-beam traps and multi-reflection time-of-flight devices has been further studied in detail. As this separation is performed during the ion storage itself, there is no need for additional external devices such as ion gates or traps for either pre- or postselection of the ions of interest. The ejection of unwanted contaminant ions is performed by appropriate pulses of the potentials of deflector electrodes. These segmented ring electrodes are located off-center in the trap, i.e., between one of the two ion mirrors and the central drift tube, which also serves as a potential lift for capturing incoming ions and axially ejecting ions of interest after their selection. The various parameters affecting the selection effectivity and resolving power are illustrated with tin-cluster measurements, where isotopologue ion species provide mass differences down to a single atomic mass unit at ion masses of several hundred. Symmetric deflection voltages of only 10 V were found sufficient for the transversal ejection of ion species with as few as three deflection pulses. The duty cycle, i.e., the pulse duration with respect to the period of ion revolution, has been varied, resulting in resolving powers of up to several tens of thousands for this selection technique.
NASA Astrophysics Data System (ADS)
Fischer, Paul; Knauer, Stefan; Marx, Gerrit; Schweikhard, Lutz
2018-01-01
The recently introduced method of ion separation by transversal ejection of unwanted species in electrostatic ion-beam traps and multi-reflection time-of-flight devices has been further studied in detail. As this separation is performed during the ion storage itself, there is no need for additional external devices such as ion gates or traps for either pre- or postselection of the ions of interest. The ejection of unwanted contaminant ions is performed by appropriate pulses of the potentials of deflector electrodes. These segmented ring electrodes are located off-center in the trap, i.e., between one of the two ion mirrors and the central drift tube, which also serves as a potential lift for capturing incoming ions and axially ejecting ions of interest after their selection. The various parameters affecting the selection effectivity and resolving power are illustrated with tin-cluster measurements, where isotopologue ion species provide mass differences down to a single atomic mass unit at ion masses of several hundred. Symmetric deflection voltages of only 10 V were found sufficient for the transversal ejection of ion species with as few as three deflection pulses. The duty cycle, i.e., the pulse duration with respect to the period of ion revolution, has been varied, resulting in resolving powers of up to several tens of thousands for this selection technique.
Low vision goggles: optical design studies
NASA Astrophysics Data System (ADS)
Levy, Ofer; Apter, Boris; Efron, Uzi
2006-08-01
Low Vision (LV) due to Age Related Macular Degeneration (AMD), Glaucoma or Retinitis Pigmentosa (RP) is a growing problem, which will affect more than 15 million people in the U.S alone in 2010. Low Vision Aid Goggles (LVG) have been under development at Ben-Gurion University and the Holon Institute of Technology. The device is based on a unique Image Transceiver Device (ITD), combining both functions of imaging and Display in a single chip. Using the ITD-based goggles, specifically designed for the visually impaired, our aim is to develop a head-mounted device that will allow the capture of the ambient scenery, perform the necessary image enhancement and processing, and re-direct it to the healthy part of the patient's retina. This design methodology will allow the Goggles to be mobile, multi-task and environmental-adaptive. In this paper we present the optical design considerations of the Goggles, including a preliminary performance analysis. Common vision deficiencies of LV patients are usually divided into two main categories: peripheral vision loss (PVL) and central vision loss (CVL), each requiring different Goggles design. A set of design principles had been defined for each category. Four main optical designs are presented and compared according to the design principles. Each of the designs is presented in two main optical configurations: See-through system and Video imaging system. The use of a full-color ITD-Based Goggles is also discussed.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-28
...] Establishing the Performance Characteristics of In Vitro Diagnostic Devices for the Detection of Antibodies to... announcing the availability of the guidance entitled ``Establishing the Performance Characteristics of In... document entitled ``Establishing the Performance Characteristics of In Vitro Diagnostic Devices for the...
Device Performance | Photovoltaic Research | NREL
Device Performance Device Performance PV Calibrations Blog Check out the latest updates from the PV than 190 person-years. Capabilities Our capabilities for measuring key performance parameters of solar cells and modules include the use of various solar simulators and tools to measure current-voltage and
Effect of traps on the charge transport in semiconducting polymer PCDTBT
NASA Astrophysics Data System (ADS)
Khan, Mohd Taukeer; Agrawal, Vikash; Almohammedi, Abdullah; Gupta, Vinay
2018-07-01
Organic semiconductors (OSCs) are nowadays called upon as promising candidates for next generation electronics devices. Due to disorder structure of these materials, a high density of traps are present in their energy band gap which affect the performance of these devices. In the present manuscript, we have investigated the role of traps on charge transport in PCDTBT thin film by measuring the temperature dependent J(V) characteristics in hole only device configuration. The obtained results were analyzed by space charge limited (SCL) conduction model. It has been found that the room temperature J(V) characteristics follow Mott-Gurney square law for trap-free SCL conduction. But below 278 K, the current increases according to trap-filling SCL law with traps distributed exponentially in the band gap of semiconductor. Furthermore, after reaching a crossover voltage of VC ∽ 12 V, all the traps filled by injected carriers and the trap-filling SCL current switch to trap-free SCL current. The hole mobility of trap-free SCL current is about one order higher as compared trap-filling SCL current and remains constant with temperature.
Numerical Study on the Thermal Stress and its Formation Mechanism of a Thermoelectric Device
NASA Astrophysics Data System (ADS)
Pan, Tao; Gong, Tingrui; Yang, Wei; Wu, Yongjia
2018-06-01
The strong thermo-mechanical stress is one of the most critical failure mechanisms that affect the durability of thermoelectric devices. In this study, numerical simulations on the formation mechanism of the maximum thermal stress inside the thermoelectric device have been performed by using finite element method. The influences of the material properties and the thermal radiation on the thermal stress have been examined. The results indicate that the maximum thermal stress was located at the contact position between the two materials and occurred due to differential thermal expansions and displacement constraints of the materials. The difference in the calculated thermal stress value between the constant and the variable material properties was between 3% and 4%. At a heat flux of 1 W·cm-2 and an emissivity of 0.5, the influence of the radiation heat transfer on the thermal stress was only about 5%; however, when the heat flux was 20 W·cm-2 and the emissivity was 0.7, the influence of the radiation heat transfer was more than 30%.
Homoepitaxial graphene tunnel barriers for spin transport
NASA Astrophysics Data System (ADS)
Friedman, Adam L.; van't Erve, Olaf M. J.; Robinson, Jeremy T.; Whitener, Keith E.; Jonker, Berend T.
2016-05-01
Tunnel barriers are key elements for both charge-and spin-based electronics, offering devices with reduced power consumption and new paradigms for information processing. Such devices require mating dissimilar materials, raising issues of heteroepitaxy, interface stability, and electronic states that severely complicate fabrication and compromise performance. Graphene is the perfect tunnel barrier. It is an insulator out-of-plane, possesses a defect-free, linear habit, and is impervious to interdiffusion. Nonetheless, true tunneling between two stacked graphene layers is not possible in environmental conditions usable for electronics applications. However, two stacked graphene layers can be decoupled using chemical functionalization. Here, we demonstrate that hydrogenation or fluorination of graphene can be used to create a tunnel barrier. We demonstrate successful tunneling by measuring non-linear IV curves and a weakly temperature dependent zero-bias resistance. We demonstrate lateral transport of spin currents in non-local spin-valve structures, and determine spin lifetimes with the non-local Hanle effect. We compare the results for hydrogenated and fluorinated tunnel and we discuss the possibility that ferromagnetic moments in the hydrogenated graphene tunnel barrier affect the spin transport of our devices.
Design and Implementation of RF Energy Harvesting System for Low-Power Electronic Devices
NASA Astrophysics Data System (ADS)
Uzun, Yunus
2016-08-01
Radio frequency (RF) energy harvester systems are a good alternative for energizing of low-power electronics devices. In this work, an RF energy harvester is presented to obtain energy from Global System for Mobile Communications (GSM) 900 MHz signals. The energy harvester, consisting of a two-stage Dickson voltage multiplier circuit and L-type impedance matching circuits, was designed, simulated, fabricated and tested experimentally in terms of its performance. Simulation and experimental works were carried out for various input power levels, load resistances and input frequencies. Both simulation and experimental works have been carried out for this frequency band. An efficiency of 45% is obtained from the system at 0 dBm input power level using the impedance matching circuit. This corresponds to the power of 450 μW and this value is sufficient for many low-power devices. The most important parameters affecting the efficiency of the RF energy harvester are the input power level, frequency band, impedance matching and voltage multiplier circuits, load resistance and the selection of diodes. RF energy harvester designs should be optimized in terms of these parameters.
Theoretical studies on stability and feasibility of 0.34 THz EIK
NASA Astrophysics Data System (ADS)
Li, Shuang; Wang, Jianguo; Wang, Guangqiang; Wang, Dongyang
2017-05-01
The stability of the circuit and the tolerance during the manufacture process are theoretically studied in the design of 0.34 THz extended interaction klystron, which are helpful to increase the feasibility of the device. By using the small signal theory, the beam-loading conductance is studied to increase the efficiency of the beam-wave interaction. Combined with the study of start current for oscillation modes, the analysis of stability in multi-gap cavity is proposed, leading to the optimization of cavity. As a crucial factor affecting the ultimate performance of device, the inaccuracy during the fabrication process is researched. The acceptable tolerance is summarized through discussion of various geometrical dimensions' influences on cavity's characteristics. The study of power loss in the conductive wall is presented and the copper is believed to be adapted in making the device practicable with low attenuation. The physical design is simulated and verified by the particle-in-cell (PIC) method, and the results show that the output power of 142 W can be reached steadily at the frequency of 347.7 GHz, approaching the gain of 37.9 dB.
Kim, Hyun K; Park, Jaehyun; Choi, Yeongcheol; Choe, Mungyeong
2018-05-01
This study aims to develop a motion sickness measurement index in a virtual reality (VR) environment. The VR market is in an early stage of market formation and technological development, and thus, research on the side effects of VR devices such as simulator motion sickness is lacking. In this study, we used the simulator sickness questionnaire (SSQ), which has been traditionally used for simulator motion sickness measurement. To measure the motion sickness in a VR environment, 24 users performed target selection tasks using a VR device. The SSQ was administered immediately after each task, and the order of work was determined using the Latin square design. The existing SSQ was revised to develop a VR sickness questionnaire, which is used as the measurement index in a VR environment. In addition, the target selection method and button size were found to be significant factors that affect motion sickness in a VR environment. The results of this study are expected to be used for measuring and designing simulator sickness using VR devices in future studies. Copyright © 2018 Elsevier Ltd. All rights reserved.
Electronic-Reconstruction-Enhanced Tunneling Conductance at Terrace Edges of Ultrathin Oxide Films.
Wang, Lingfei; Kim, Rokyeon; Kim, Yoonkoo; Kim, Choong H; Hwang, Sangwoon; Cho, Myung Rae; Shin, Yeong Jae; Das, Saikat; Kim, Jeong Rae; Kalinin, Sergei V; Kim, Miyoung; Yang, Sang Mo; Noh, Tae Won
2017-11-01
Quantum mechanical tunneling of electrons across ultrathin insulating oxide barriers has been studied extensively for decades due to its great potential in electronic-device applications. In the few-nanometers-thick epitaxial oxide films, atomic-scale structural imperfections, such as the ubiquitously existed one-unit-cell-high terrace edges, can dramatically affect the tunneling probability and device performance. However, the underlying physics has not been investigated adequately. Here, taking ultrathin BaTiO 3 films as a model system, an intrinsic tunneling-conductance enhancement is reported near the terrace edges. Scanning-probe-microscopy results demonstrate the existence of highly conductive regions (tens of nanometers wide) near the terrace edges. First-principles calculations suggest that the terrace-edge geometry can trigger an electronic reconstruction, which reduces the effective tunneling barrier width locally. Furthermore, such tunneling-conductance enhancement can be discovered in other transition metal oxides and controlled by surface-termination engineering. The controllable electronic reconstruction can facilitate the implementation of oxide electronic devices and discovery of exotic low-dimensional quantum phases. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Bae, Yoon Cheol; Lee, Ah Rahm; Baek, Gwang Ho; Chung, Je Bock; Kim, Tae Yoon; Park, Jea Gun; Hong, Jin Pyo
2015-01-01
Three-dimensional (3D) stackable memory devices including nano-scaled crossbar array are central for the realization of high-density non-volatile memory electronics. However, an essential sneak path issue affecting device performance in crossbar array remains a bottleneck and a grand challenge. Therefore, a suitable bidirectional selector as a two-way switch is required to facilitate a major breakthrough in the 3D crossbar array memory devices. Here, we show the excellent selectivity of all oxide p-/n-type semiconductor-based p-n-p open-based bipolar junction transistors as selectors in crossbar memory array. We report that bidirectional nonlinear characteristics of oxide p-n-p junctions can be highly enhanced by manipulating p-/n-type oxide semiconductor characteristics. We also propose an associated Zener tunneling mechanism that explains the unique features of our p-n-p selector. Our experimental findings are further extended to confirm the profound functionality of oxide p-n-p selectors integrated with several bipolar resistive switching memory elements working as storage nodes. PMID:26289565
Bienek, Diane R; Charlton, David G
2012-05-01
Being able to test for the presence of blood pathogens at forward locations could reduce morbidity and mortality in the field. Rapid, user-friendly blood typing kits for detecting Human Immunodeficiency Virus (HIV), Hepatitis C Virus (HCV), and Hepatitis B Virus (HBV) were evaluated to determine their accuracy after storage at various temperatures/humidities. Rates of positive tests of control groups, experimental groups, and industry standards were compared (Fisher's exact chi2, p < or = 0.05). Compared to the control group, 2 of 10 HIV detection devices were adversely affected by exposure to high temperature/high humidity or high temperature/low humidity. With one exception, none of the environmentally exposed HCV or HBV detection devices exhibited significant differences compared to those stored under control conditions. For HIV, HCV, and HBV devices, there were differences compared to the industry standard. Collectively, this evaluation of pathogen detection kits revealed that diagnostic performance varies among products and storage conditions, and that the tested products cannot be considered to be approved for use to screen blood, plasma, cell, or tissue donors.
40 CFR 610.21 - Device functional category and vehicle system effects.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 1 Device categories Characteristics adversely affected Fuel-Air System Carburetors and fuel injection systems All. Air-fuel ratio modifiers (e.g., air bleeds) All. Atomization devices (acoustic and mechanical) All. Vapor Injectors All. Choke controls 1, 2, and 4. Air filters 1, 2, and 4. Fuel-air...
40 CFR 610.21 - Device functional category and vehicle system effects.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 1 Device categories Characteristics adversely affected Fuel-Air System Carburetors and fuel injection systems All. Air-fuel ratio modifiers (e.g., air bleeds) All. Atomization devices (acoustic and mechanical) All. Vapor Injectors All. Choke controls 1, 2, and 4. Air filters 1, 2, and 4. Fuel-air...
Treatment of a unicameral bone cyst in a dog using a customized titanium device.
Nojiri, Ayami; Akiyoshi, Hideo; Ohashi, Fumihito; Ijiri, Atsuki; Sawase, Osamu; Matsushita, Tomiharu; Takemoto, Mitsuru; Fujibayashi, Shunsuke; Nakamura, Takashi; Yamaguchi, Tsutomu
2015-01-01
A 4-year-old Shih-Tzu, referred for an enlarged left carpus, was diagnosed with a unicameral bone cyst. A customized titanium device was inserted into cystic lesion and fixed by titanium screws. Sufficient strength of the affected bone with the device inserted to maintain limb function was established after resection of contents of cystic lesion. There was no deterioration of the lesion of bone cyst, and acceptable function of the affected limb with no clinical signs of lameness was maintained during 36 months follow-up. The results of this study demonstrated that bone cyst curettage and use of a customized titanium device could provide an effective alternative treatment of huge lesion of unicameral bone cysts with the intent of preventing pathologic fractures.
Treatment of a unicameral bone cyst in a dog using a customized titanium device
NOJIRI, Ayami; AKIYOSHI, Hideo; OHASHI, Fumihito; IJIRI, Atsuki; SAWASE, Osamu; MATSUSHITA, Tomiharu; TAKEMOTO, Mitsuru; FUJIBAYASHI, Shunsuke; NAKAMURA, Takashi; YAMAGUCHI, Tsutomu
2014-01-01
ABSTRACT A 4-year-old Shih-Tzu, referred for an enlarged left carpus, was diagnosed with a unicameral bone cyst. A customized titanium device was inserted into cystic lesion and fixed by titanium screws. Sufficient strength of the affected bone with the device inserted to maintain limb function was established after resection of contents of cystic lesion. There was no deterioration of the lesion of bone cyst, and acceptable function of the affected limb with no clinical signs of lameness was maintained during 36 months follow-up. The results of this study demonstrated that bone cyst curettage and use of a customized titanium device could provide an effective alternative treatment of huge lesion of unicameral bone cysts with the intent of preventing pathologic fractures. PMID:25319515
Code of Federal Regulations, 2010 CFR
2010-07-01
... device operating limits during the performance test? 63.3167 Section 63.3167 Protection of Environment... Limitations § 63.3167 How do I establish the add-on control device operating limits during the performance.... (a) Thermal oxidizers. If your add-on control device is a thermal oxidizer, establish the operating...
Morgan, Jeremy P; Miller, Ashley L; Thompson, Paul A; Asfora, Wilson T
2016-04-01
Low back pain and degeneration of the intervertebral disc are an integrated malady that affects millions of Americans. Cage devices used in association with posterior lumbar interbody fusion (PLIF) have been shown to be an effective approach in the treatment of a number of lower spine disorders attributed to degenerative disc disease (DDD). This study was undertaken as part of a U.S. Food and Drug Administration (FDA) Investigational Device Exemption (IDE) study and compares the effectiveness of the Asfora Bullet Cage System (ABCS) to successfully fuse vertebra at one or two levels between L2 and S1 in patients with DDD to an FDA approved comparison device, the Medtronic-Sofamor Danek Inter Fix Threaded Fusion Device (MSDIFD). A total of 257 randomized participants were implanted with either the ABCS device (n = 132) or the MSDIFD device (n = 125) through an open posterior approach using autogenous local bone graft without the use of pedicle screws. Patients were evaluated prior to surgery and at the 24 month (24-M) visit for fusion status, deep tendon reflex status, sensory function, motor function, straight leg raise status, pain, disability, and device safety. Radiological evaluation and statistical analysis were performed by independent professionals. Evaluation of device success was performed at 24-M visit. From the original group of 257 patients, 59 were lost to follow-up. Primary measures of success at the 24-M visit involved pain and function, fusion, neurological status, and device-related adverse events measures. Pain and function improved in both (MSDIFD: 75.7 percent; ABCS: 82.6 percent). Fusion success with all radiographic points at 24-M visits was 79.4 percent MSDIFD and 88.2 percent ABCS. Neurological improvement was seen in both (MSDIFD: 77.0 percent; ABCS: 87.8 percent). One device-related grade 1 adverse event was reported in the MSDIFD group. Disc height preservation was equivalent for single level fusions (MSDIFD: 16.1 percent; ABCS: 20.0 percent) and second level fusions (MSDIFD: 10.7 percent; ABCS: 14.3 percent). General health and well-being improvement was the same (MSDIFD: 37.0 percent; ABCS: 40.0 percent). Subsequent fusion, up to 10 years, was equivalent (MSDIFD: 83.8 percent; ABCS: 91.2). Results for both devices were considered to be satisfactory, with a slight non-significant superiority for the ABCS. From the ABCS device FDA IDE sanctioned study and the review of the literature, we concluded that the Asfora Bullet Cage System is safe, effective and comparable to other interbody fusion devices which are used stand-alone or in conjunction with pedicle screws, rhBMP-2, or autogenous bone harvested from the iliac crest inserted through anterior, lateral or posterior approaches.
NASA Astrophysics Data System (ADS)
Pang, Huan; Li, Xinran; Li, Bing; Zhang, Yizhou; Zhao, Qunxing; Lai, Wen-Yong; Huang, Wei
2016-06-01
Dimanganese trioxide microflowers are easily obtained from a Mn(ii) 8-hydroxyquinoline microcoordination after calcination in air. We also look into the possible formation mechanism of the flower-like morphology, and find that the reaction time affects the morphology of the coordination. Furthermore, the as-prepared porous Mn2O3 microflowers are made of many nanoplates which form many nanogaps and nanochannels. Interestingly, the assembled electrode based on the as-prepared porous Mn2O3 microflowers proves to be a high-performance electrode material for supercapacitors. The electrode shows a specific capacitance of 994 F g-1, which can work well even after 4000 cycles at 0.75 A g-1. More importantly, the porous Mn2O3 microflowers and activated carbons are assembled into a high-performance flexible solid-state asymmetric supercapacitor with a specific capacitance of 312.5 mF cm-2. The cycle test shows that the device can offer 95.6% capacity of the initial capacitance at 2.0 mA cm-2 after 5000 cycles with little decay. The maximum energy density of the device can achieve 6.56 mWh cm-3 and the maximum power density can also achieve 283.5 mW cm-3, which are among the best results for manganese based materials.Dimanganese trioxide microflowers are easily obtained from a Mn(ii) 8-hydroxyquinoline microcoordination after calcination in air. We also look into the possible formation mechanism of the flower-like morphology, and find that the reaction time affects the morphology of the coordination. Furthermore, the as-prepared porous Mn2O3 microflowers are made of many nanoplates which form many nanogaps and nanochannels. Interestingly, the assembled electrode based on the as-prepared porous Mn2O3 microflowers proves to be a high-performance electrode material for supercapacitors. The electrode shows a specific capacitance of 994 F g-1, which can work well even after 4000 cycles at 0.75 A g-1. More importantly, the porous Mn2O3 microflowers and activated carbons are assembled into a high-performance flexible solid-state asymmetric supercapacitor with a specific capacitance of 312.5 mF cm-2. The cycle test shows that the device can offer 95.6% capacity of the initial capacitance at 2.0 mA cm-2 after 5000 cycles with little decay. The maximum energy density of the device can achieve 6.56 mWh cm-3 and the maximum power density can also achieve 283.5 mW cm-3, which are among the best results for manganese based materials. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr02267g
Electronic medication packaging devices and medication adherence: a systematic review.
Checchi, Kyle D; Huybrechts, Krista F; Avorn, Jerry; Kesselheim, Aaron S
2014-09-24
Medication nonadherence, which has been estimated to affect 28% to 31% of US patients with hypertension, hyperlipidemia, and diabetes, may be improved by electronic medication packaging (EMP) devices (adherence-monitoring devices incorporated into the packaging of a prescription medication). To investigate whether EMP devices are associated with improved adherence and to identify and describe common features of EMP devices. Systematic review of peer-reviewed studies testing the effectiveness of EMP systems in the MEDLINE, EMBASE, PsycINFO, CINAHL, International Pharmaceutical Abstracts, and Sociological Abstracts databases from searches conducted to June 13, 2014, with extraction of associations between the interventions and adherence, as well as other key findings. Each study was assessed for bias using the Cochrane Handbook for Systematic Reviews of Interventions; features of EMP devices and interventions were qualitatively assessed. Thirty-seven studies (32 randomized and 5 nonrandomized) including 4326 patients met inclusion criteria (10 patient interface-only "simple" interventions and 29 "complex" interventions integrated into the health care system [2 qualified for both categories]). Overall, the effect estimates for differences in mean adherence ranged from a decrease of 2.9% to an increase of 34.0%, and the those for differences in the proportion of patients defined as adherent ranged from a decrease of 8.0% to an increase of 49.5%. We identified 5 common EMP characteristics: recorded dosing events and stored records of adherence, audiovisual reminders to cue dosing, digital displays, real-time monitoring, and feedback on adherence performance. Many varieties of EMP devices exist. However, data supporting their use are limited, with variability in the quality of studies testing EMP devices. Devices integrated into the care delivery system and designed to record dosing events are most frequently associated with improved adherence, compared with other devices. Higher-quality evidence is needed to determine the effect, if any, of these low-cost interventions on medication nonadherence and to identify their most useful components.
Exer-Genie(Registered Trademark) Exercise Device Hardware Evaluation
NASA Technical Reports Server (NTRS)
Schaffner, Grant; Sharp,Carwyn; Stroud, Leah
2008-01-01
An engineering evaluation was performed on the ExerGenie(r) exercise device to quantify its capabilities and limitations to address questions from the Constellation Program. Three subjects performed rowing and circuit training sessions to assess the suitability of the device for aerobic exercise. Three subjects performed a resistive exercise session to assess the suitability of the device for resistive exercise. Since 1 subject performed both aerobic and resistive exercise sessions, a total of 5 subjects participated.
The effects of platform motion and target orientation on the performance of trackball manipulation.
Yau, Yi-Jan; Chao, Chin-Jung; Feng, Wen-Yang; Hwang, Sheue-Ling
2011-08-01
The trackball has been widely employed as a control/command input device on moving vehicles, but few studies have explored the effects of platform motion on its manipulation. Fewer still have considered this issue in designing the user interface and the arrangement of console location and orientation simultaneously. This work describes an experiment carried out to investigate the performance of trackball users on a simple point-and-click task in a motion simulator. By varying the orientation of onscreen targets, the effect of cursor movement direction on performance is investigated. The results indicate that the platform motion and target orientation both significantly affect the time required to point and click, but not the accuracy of target selection. The movement times were considerably longer under rolling and pitching motions and for targets located along the diagonal axes of the interface. Subjective evaluations carried out by the participants agree with these objective results. These findings could be used to optimise console and graphical menu design for use on maritime vessels. STATEMENT OF RELEVANCE: In military situations, matters of life or death may be decided in milliseconds. Any delay or error in classification and identification will thus affect the safety of the ship and its crew. This study demonstrates that performance of manipulating a trackball is affected by the platform motion and target orientation. The results of the present study can guide the arrangement of consoles and the design of trackball-based graphical user interfaces on maritime vessels.
DE SOUZA, Grace; BRAGA, Roberto Ruggiero; CESAR, Paulo Francisco; LOPES, Guilherme Carpena
2015-01-01
Resin-based cements have been frequently employed in clinical practice to lute indirect restorations. However, there are numerous factors that may compromise the clinical performance of those cements. The aim of this literature review is to present and discuss some of the clinical factors that may affect the performance of current resin-based luting systems. Resin cements may have three different curing mechanisms: chemical curing, photo curing or a combination of both. Chemically cured systems are recommended to be used under opaque or thick restorations, due to the reduced access of the light. Photo-cured cements are mainly indicated for translucent veneers, due to the possibility of light transmission through the restoration. Dual-cured are more versatile systems and, theoretically, can be used in either situation, since the presence of both curing mechanisms might guarantee a high degree of conversion (DC) under every condition. However, it has been demonstrated that clinical procedures and characteristics of the materials may have many different implications in the DC of currently available resin cements, affecting their mechanical properties, bond strength to the substrate and the esthetic results of the restoration. Factors such as curing mechanism, choice of adhesive system, indirect restorative material and light-curing device may affect the degree of conversion of the cement and, therefore, have an effect on the clinical performance of resin-based cements. Specific measures are to be taken to ensure a higher DC of the luting system to be used. PMID:26398507
NASA Astrophysics Data System (ADS)
Barbieri, Enrico; Tanganelli, Pietro; Taddei, Giuseppe; Perbellini, Antonio; Attino, Vito; Destro, Gianni; Zardini, Piero
1991-05-01
Laser balloon angioplasty has been used in recent years to treat peripheral artery disease. Despite a primary success the technique is plagued by a high restenosis rate. Directional atherectomy was performed in a small group of patients affected by primitive stenosis or restenosis after an invasive procedure. Light microscopy, immunohistochemistry, and transmission electron microscopy have identified the cellular component of intimal hyperplasia as smooth muscle cells in an active synthetic phenotype. The arterial healing process after invasive procedures seems to develop similarly independently of the device employed.
Xu, Ke; Butlin, Mark; Avolio, Alberto P
2012-01-01
Timing of biventricular pacing devices employed in cardiac resynchronization therapy (CRT) is a critical determinant of efficacy of the procedure. Optimization is done by maximizing function in terms of arterial pressure (BP) or cardiac output (CO). However, BP and CO are also determined by the hemodynamic load of the pulmonary and systemic vasculature. This study aims to use a lumped parameter circulatory model to assess the influence of the arterial load on the atrio-ventricular (AV) and inter-ventricular (VV) delay for optimal CRT performance.
Progress toward an advanced condition monitoring system for reusable rocket engines
NASA Technical Reports Server (NTRS)
Maram, J.; Barkhoudarian, S.
1987-01-01
A new generation of advanced sensor technologies will allow the direct measurement of critical/degradable rocket engine components' health and the detection of degraded conditions before component deterioration affects engine performance, leading to substantial improvements in reusable engines' operation and maintenance. When combined with a computer-based engine condition-monitoring system, these sensors can furnish a continuously updated data base for the prediction of engine availability and advanced warning of emergent maintenance requirements. Attention is given to the case of a practical turbopump and combustion device diagnostic/prognostic health-monitoring system.
Static power reduction for midpoint-terminated busses
Coteus, Paul W [Yorktown Heights, NY; Takken, Todd [Brewster, NY
2011-01-18
A memory system is disclosed which is comprised of a memory controller and addressable memory devices such as DRAMs. The invention provides a programmable register to control the high vs. low drive state of each bit of a memory system address and control bus during periods of bus inactivity. In this way, termination voltage supply current can be minimized, while permitting selected bus bits to be driven to a required state. This minimizes termination power dissipation while not affecting memory system performance. The technique can be extended to work for other high-speed busses as well.
Force and power characteristics of a resistive exercise device for use in space
NASA Astrophysics Data System (ADS)
Berg, Hans E.; Tesch, Per A.
We have developed a non-gravity dependent mechanical device, which provides resistance during coupled concentric and eccentric muscle actions, through the inertia of a spinning fly-wheel (Fly-Wheel Ergometry; FWE). Our research shows that lower-limb FWE exercise can produce forces and thus muscular stress comparable to what is typical of advanced resistance training using free weights. FWE also offers greater training stimuli during eccentric relative to concentric muscle actions, as evidenced by force and electromyographic (EMG) measurements. Muscle use of specific muscle groups, as assessed by the exercise-induced contrast shift of magnetic resonance images, is similar during lower-limb FWE and the barbell squat. Unlike free-weight exercise, FWE allows for maximal voluntary effort in each repetition of an exercise bout. Likewise, FWE exercise, not unassisted free-weight exercise, produces eccentric "overload". Collectively, the inherent features of this resistive exercise device and the results of the physiological evaluations we have performed, suggest that resistance exercise using FWE could be used as an effective exercise counter-measure in space. The flywheel principle can be employed to any exercise configuration and designed into a compact device allowing for exercises stressing those muscles and bone structures, which are thought to be most affected by long-duration spaceflight.
NASA Astrophysics Data System (ADS)
Alim, Mohammad A.; Ali, Mayahsa M.; Haris, Norshakila; Kyabaggu, Peter B. K.; Rezazadeh, Ali A.
2017-05-01
This study focuses on the characterization of two 0.5 μm gate-length double heterojunction AlGaAs/InGaAs/GaAs pHEMTs using pre and post fabricated vertical oriented multilayer 3D monolithic microwave integrated (MMIC) circuit technology. The effects of the presence of 3D components above the active layer were accomplished by means of capacitance-voltage measurement, on-wafer DC and S-parameter measurements and two-tone intermodulation distortion measurement. The barrier height, donor concentration in the barrier layer, existing two-dimensional electron gas, output current, off and on state leakage, transconductance, cut-off frequency, small signal model parameters, gain, minimum noise figures and nonlinear distortion behavior reveals no significant performance degradation. Furthermore the fundamental device properties such as the depletion depth d, the sheet charge densities of the 2-DEG, n s, filed dependent mobility, μ, and the effective carrier velocity, v eff is not much affected due to multilayer processing. Less than 5% changes in magnitude of the device parameters are realized between the pre and post fabricated multilayer 3D MMIC technology. These effective comparisons of the both device are useful for future designs and optimizations of multilayer vertical stacked 3D MMICs.
Characterization of Zinc Oxide (ZnO) piezoelectric properties for Surface Acoustic Wave (SAW) device
NASA Astrophysics Data System (ADS)
Rosydi Zakaria, Mohd; Johari, Shazlina; Hafiz Ismail, Mohd; Hashim, Uda
2017-11-01
In fabricating Surface Acoustic Wave (SAW) biosensors device, the substrate is one of important factors that affected to performance device. there are many types of piezoelectric substrate in the markets and the cheapest is zinc Oxide substrate. Zinc Oxide (ZnO) with its unique properties can be used as piezoelectric substrate along with SAW devices for detection of DNA in this research. In this project, ZnO thin film is deposited onto silicon oxide substrate using electron beam evaporation (E-beam) and Sol-Gel technique. Different material structure is used to compare the roughness and best piezoelectric substrate of ZnO thin film. Two different structures of ZnO target which are pellet and granular are used for e-beam deposition and one sol-gel liquid were synthesize and compared. Parameter for thickness of ZnO e-beam deposition is fixed to a 0.1kÅ for both materials structure and sol-gel was coat using spin coat technique. After the process is done, samples are annealed at temperature of 500°C for 2 hours. The structural properties of effect of post annealing using different material structure of ZnO are studied using Atomic Force Microscopic (AFM) for surface morphology and X-ray Diffraction (XRD) for phase structure.
16 CFR 1750.5 - Detailed requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... effects from spillage, cleaning, defrosting, and condensation. Devices shall be designed so that spillage... normal condensation will not so adversely affect the operation of the device as to result in its failure...
16 CFR 1750.5 - Detailed requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... effects from spillage, cleaning, defrosting, and condensation. Devices shall be designed so that spillage... normal condensation will not so adversely affect the operation of the device as to result in its failure...
16 CFR 1750.5 - Detailed requirements.
Code of Federal Regulations, 2014 CFR
2014-01-01
... effects from spillage, cleaning, defrosting, and condensation. Devices shall be designed so that spillage... normal condensation will not so adversely affect the operation of the device as to result in its failure...
Parietal neural prosthetic control of a computer cursor in a graphical-user-interface task
NASA Astrophysics Data System (ADS)
Revechkis, Boris; Aflalo, Tyson NS; Kellis, Spencer; Pouratian, Nader; Andersen, Richard A.
2014-12-01
Objective. To date, the majority of Brain-Machine Interfaces have been used to perform simple tasks with sequences of individual targets in otherwise blank environments. In this study we developed a more practical and clinically relevant task that approximated modern computers and graphical user interfaces (GUIs). This task could be problematic given the known sensitivity of areas typically used for BMIs to visual stimuli, eye movements, decision-making, and attentional control. Consequently, we sought to assess the effect of a complex, GUI-like task on the quality of neural decoding. Approach. A male rhesus macaque monkey was implanted with two 96-channel electrode arrays in area 5d of the superior parietal lobule. The animal was trained to perform a GUI-like ‘Face in a Crowd’ task on a computer screen that required selecting one cued, icon-like, face image from a group of alternatives (the ‘Crowd’) using a neurally controlled cursor. We assessed whether the crowd affected decodes of intended cursor movements by comparing it to a ‘Crowd Off’ condition in which only the matching target appeared without alternatives. We also examined if training a neural decoder with the Crowd On rather than Off had any effect on subsequent decode quality. Main results. Despite the additional demands of working with the Crowd On, the animal was able to robustly perform the task under Brain Control. The presence of the crowd did not itself affect decode quality. Training the decoder with the Crowd On relative to Off had no negative influence on subsequent decoding performance. Additionally, the subject was able to gaze around freely without influencing cursor position. Significance. Our results demonstrate that area 5d recordings can be used for decoding in a complex, GUI-like task with free gaze. Thus, this area is a promising source of signals for neural prosthetics that utilize computing devices with GUI interfaces, e.g. personal computers, mobile devices, and tablet computers.
Parietal neural prosthetic control of a computer cursor in a graphical-user-interface task.
Revechkis, Boris; Aflalo, Tyson N S; Kellis, Spencer; Pouratian, Nader; Andersen, Richard A
2014-12-01
To date, the majority of Brain-Machine Interfaces have been used to perform simple tasks with sequences of individual targets in otherwise blank environments. In this study we developed a more practical and clinically relevant task that approximated modern computers and graphical user interfaces (GUIs). This task could be problematic given the known sensitivity of areas typically used for BMIs to visual stimuli, eye movements, decision-making, and attentional control. Consequently, we sought to assess the effect of a complex, GUI-like task on the quality of neural decoding. A male rhesus macaque monkey was implanted with two 96-channel electrode arrays in area 5d of the superior parietal lobule. The animal was trained to perform a GUI-like 'Face in a Crowd' task on a computer screen that required selecting one cued, icon-like, face image from a group of alternatives (the 'Crowd') using a neurally controlled cursor. We assessed whether the crowd affected decodes of intended cursor movements by comparing it to a 'Crowd Off' condition in which only the matching target appeared without alternatives. We also examined if training a neural decoder with the Crowd On rather than Off had any effect on subsequent decode quality. Despite the additional demands of working with the Crowd On, the animal was able to robustly perform the task under Brain Control. The presence of the crowd did not itself affect decode quality. Training the decoder with the Crowd On relative to Off had no negative influence on subsequent decoding performance. Additionally, the subject was able to gaze around freely without influencing cursor position. Our results demonstrate that area 5d recordings can be used for decoding in a complex, GUI-like task with free gaze. Thus, this area is a promising source of signals for neural prosthetics that utilize computing devices with GUI interfaces, e.g. personal computers, mobile devices, and tablet computers.
Development of GaInP Solar Cells Grown by Hydride Vapor Phase Epitaxy
Schulte, Kevin L.; Simon, John; Mangum, John; ...
2017-04-30
We demonstrate the growth of homojunction GaInP solar cells by dynamic hydride vapor phase epitaxy for the first time. Simple unpassivated n-on-p structures grown in an inverted configuration with gold back reflectors were analyzed. Short wavelength performance varied strongly with emitter thickness, since collection in the emitter was limited by the lack of surface passivation. Collection in the base increased strongly with decreasing doping density, in the range 1 x 10 16 - 5 x 10 17 cm -3. Optical modeling indicated that, in our best device, doped ~1 x 10 16 cm -3, almost 94% of photons that passedmore » through the emitter were collected. Modeling also indicated that the majority of collection occurs in the depletion region with this design, suggesting that nonradiative recombination there might limit device performance. In agreement with this observation, the experimental dark J-V curve exhibited an ideality factor near n = 2. Thus, limitation of deep level carrier traps in the material is a path to improved performance. Preliminary experiments indicate that a reduced V/III ratio, which potentially affects the density of these presumed traps, improves cell performance. With reduced V/III ratio, we demonstrate a ~13% efficient GaInP cell measured under the 1-sun AM1.5G spectrum. In conclusion, this cell had an antireflective coating, but no front surface passivation.« less
Progress and Design Concerns of Nanostructured Solar Energy Harvesting Devices.
Leung, Siu-Fung; Zhang, Qianpeng; Tavakoli, Mohammad Mahdi; He, Jin; Mo, Xiaoliang; Fan, Zhiyong
2016-05-01
Integrating devices with nanostructures is considered a promising strategy to improve the performance of solar energy harvesting devices such as photovoltaic (PV) devices and photo-electrochemical (PEC) solar water splitting devices. Extensive efforts have been exerted to improve the power conversion efficiencies (PCE) of such devices by utilizing novel nanostructures to revolutionize device structural designs. The thicknesses of light absorber and material consumption can be substantially reduced because of light trapping with nanostructures. Meanwhile, the utilization of nanostructures can also result in more effective carrier collection by shortening the photogenerated carrier collection path length. Nevertheless, performance optimization of nanostructured solar energy harvesting devices requires a rational design of various aspects of the nanostructures, such as their shape, aspect ratio, periodicity, etc. Without this, the utilization of nanostructures can lead to compromised device performance as the incorporation of these structures can result in defects and additional carrier recombination. The design guidelines of solar energy harvesting devices are summarized, including thin film non-uniformity on nanostructures, surface recombination, parasitic absorption, and the importance of uniform distribution of photo-generated carriers. A systematic view of the design concerns will assist better understanding of device physics and benefit the fabrication of high performance devices in the future. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Li, Qian; Li, Shilong; Yang, Dehua; Su, Wei; Wang, Yanchun; Zhou, Weiya; Liu, Huaping; Xie, Sishen
2017-10-01
The electrical characteristics of carbon nanotube (CNT) thin-film transistors (TFTs) strongly depend on the properties of the gate dielectric that is in direct contact with the semiconducting CNT channel materials. Here, we systematically investigated the dielectric effects on the electrical characteristics of fully printed semiconducting CNT-TFTs by introducing the organic dielectrics of poly(methyl methacrylate) (PMMA) and octadecyltrichlorosilane (OTS) to modify SiO2 dielectric. The results showed that the organic-modified SiO2 dielectric formed a favorable interface for the efficient charge transport in s-SWCNT-TFTs. Compared to single-layer SiO2 dielectric, the use of organic-inorganic hybrid bilayer dielectrics dramatically improved the performances of SWCNT-TFTs such as mobility, threshold voltage, hysteresis and on/off ratio due to the suppress of charge scattering, gate leakage current and charge trapping. The transport mechanism is related that the dielectric with few charge trapping provided efficient percolation pathways for charge carriers, while reduced the charge scattering. High density of charge traps which could directly act as physical transport barriers and significantly restrict the charge carrier transport and, thus, result in decreased mobile carriers and low device performance. Moreover, the gate leakage phenomenon is caused by conduction through charge traps. So, as a component of TFTs, the gate dielectric is of crucial importance to the manufacture of high quality TFTs from the aspects of affecting the gate leakage current and device operation voltage, as well as the charge carrier transport. Interestingly, the OTS-modified SiO2 allows to directly print horizontally aligned CNT film, and the corresponding devices exhibited a higher mobility than that of the devices with the hybrid PMMA/SiO2 dielectric although the thickness of OTS layer is only ˜2.5 nm. Our present result may provide key guidance for the further development of printed nanomaterial electronics.
Metastability and reliability of CdTe solar cells
NASA Astrophysics Data System (ADS)
Guo, Da; Brinkman, Daniel; Shaik, Abdul R.; Ringhofer, Christian; Vasileska, Dragica
2018-04-01
Thin-film modules of all technologies often suffer from performance degradation over time. Some of the performance changes are reversible and some are not, which makes deployment, testing, and energy-yield prediction more challenging. Manufacturers devote significant empirical efforts to study these phenomena and to improve semiconductor device stability. Still, understanding the underlying reasons of these instabilities remains clouded due to the lack of ability to characterize materials at atomistic levels and the lack of interpretation from the most fundamental material science. The most commonly alleged causes of metastability in CdTe devices, such as ‘migration of Cu’, have been investigated rigorously over the past fifteen years. Still, the discussion often ended prematurely with stating observed correlations between stress conditions and changes in atomic profiles of impurities or CV doping concentration. Multiple hypotheses suggesting degradation of CdTe solar cell devices due to interaction and evolution of point defects and complexes were proposed, and none of them received strong theoretical or experimental confirmation. It should be noted that atomic impurity profiles in CdTe provide very little intelligence on active doping concentrations. The same elements could form different energy states, which could be either donors or acceptors, depending on their position in crystalline lattice. Defects interact with other extrinsic and intrinsic defects; for example, changing the state of an impurity from an interstitial donor to a substitutional acceptor often is accompanied by generation of a compensating intrinsic interstitial donor defect. Moreover, all defects, intrinsic and extrinsic, interact with the electrical potential and free carriers so that charged defects may drift in the electric field and the local electrical potential affects the formation energy of the point defects. Such complexity of interactions in CdTe makes understanding of temporal changes in device performance even more challenging and a closed solution that can treat the entire system and its interactions is required.
Fabricating Germanium Interfaces for Battery Applications
NASA Astrophysics Data System (ADS)
Serino, Andrew Clark
The experimental results presented herein detail the importance of material surfaces in device performance. We have demonstrated this importance by furthering and applying our understanding of germanium surfaces to a number of real-world applications. Pure and stable dispersions of germanane, an "all-surface" form of germanium, were created through solid-state synthesis followed by ultrasonication and centrifugation. These dispersions were used to fabricate germanane-based, high-performance, Li-ion anodes with capacities of ˜1100 mA-h/g, capacity retention over 100 cycles, and Coulombic efficiency of 99%. Additionally, carborane monolayers were self-assembled on Ge(100) and Ge(111) surfaces through carboxylic acid tethers, and found to be capable of tuning the surface work function by ˜0.4 eV without significantly affecting surface wettability. These capabilities are important for increasing device efficiency while minimizing complications associated with processing. Lastly, we introduce the concept of the molecular battery, a possible design using a layer-by-layer deposition approach, and our steps toward its realization. In this pursuit, we explored the assembly of metal-organic coordination of carborane-based linkers, as well as the capabilities of a film of benzene-based linkers (<50 nm) as a Li-ion battery separator using a Ge anode as a tool for analyzing performance.
Design of Supercapacitor Electrodes Using Molecular Dynamics Simulations
NASA Astrophysics Data System (ADS)
Bo, Zheng; Li, Changwen; Yang, Huachao; Ostrikov, Kostya; Yan, Jianhua; Cen, Kefa
2018-06-01
Electric double-layer capacitors (EDLCs) are advanced electrochemical devices for energy storage and have attracted strong interest due to their outstanding properties. Rational optimization of electrode-electrolyte interactions is of vital importance to enhance device performance for practical applications. Molecular dynamics (MD) simulations could provide theoretical guidelines for the optimal design of electrodes and the improvement of capacitive performances, e.g., energy density and power density. Here we discuss recent MD simulation studies on energy storage performance of electrode materials containing porous to nanostructures. The energy storage properties are related to the electrode structures, including electrode geometry and electrode modifications. Altering electrode geometry, i.e., pore size and surface topography, can influence EDL capacitance. We critically examine different types of electrode modifications, such as altering the arrangement of carbon atoms, doping heteroatoms and defects, which can change the quantum capacitance. The enhancement of power density can be achieved by the intensified ion dynamics and shortened ion pathway. Rational control of the electrode morphology helps improve the ion dynamics by decreasing the ion diffusion pathway. Tuning the surface properties (e.g., the affinity between the electrode and the ions) can affect the ion-packing phenomena. Our critical analysis helps enhance the energy and power densities of EDLCs by modulating the corresponding electrode structures and surface properties.[Figure not available: see fulltext.
Literature Review on Needs of Upper Limb Prosthesis Users.
Cordella, Francesca; Ciancio, Anna Lisa; Sacchetti, Rinaldo; Davalli, Angelo; Cutti, Andrea Giovanni; Guglielmelli, Eugenio; Zollo, Loredana
2016-01-01
The loss of one hand can significantly affect the level of autonomy and the capability of performing daily living, working and social activities. The current prosthetic solutions contribute in a poor way to overcome these problems due to limitations in the interfaces adopted for controlling the prosthesis and to the lack of force or tactile feedback, thus limiting hand grasp capabilities. This paper presents a literature review on needs analysis of upper limb prosthesis users, and points out the main critical aspects of the current prosthetic solutions, in terms of users satisfaction and activities of daily living they would like to perform with the prosthetic device. The ultimate goal is to provide design inputs in the prosthetic field and, contemporary, increase user satisfaction rates and reduce device abandonment. A list of requirements for upper limb prostheses is proposed, grounded on the performed analysis on user needs. It wants to (i) provide guidelines for improving the level of acceptability and usefulness of the prosthesis, by accounting for hand functional and technical aspects; (ii) propose a control architecture of PNS-based prosthetic systems able to satisfy the analyzed user wishes; (iii) provide hints for improving the quality of the methods (e.g., questionnaires) adopted for understanding the user satisfaction with their prostheses.
Influence of silicon oxide on the performance of TiN bottom electrode in phase change memory
NASA Astrophysics Data System (ADS)
Gao, Dan; Liu, Bo; Xu, Zhen; Wang, Heng; Xia, Yangyang; Wang, Lei; Zhu, Nanfei; Li, Ying; Zhan, Yipeng; Song, Zhitang; Feng, Songlin
2016-10-01
The stability of TiN which is the preferred bottom electrode contact (BEC) of phase change memory (PCM) due to its low thermal conductivity and suitable electrical conductivity, is very essential to the reliability of PCM devices. In this work, in order to investigate the effect of high aspect ratio process (HARP) SiO2 on the performance of TiN, both TiN/SiO2, TiN/SiN thin films and TiN BEC device structures are analyzed. By combining transmission electron microscopy (TEM) and energy dispersive X-ray spectroscopy (EDS), we found that the TiN would be oxidized after the deposition of HARP SiO2 and there exist a thin ( 4 nm) oxidation interfacial layer between TiN and SiO2. Electrical measurements were performed on the 1R PCM test-key die with 7 nm and 10 nm BEC-only cells. The statistical initial resistances of BEC have wide distribution and it is confirmed that the non-uniform oxidation of TiN BEC affects the astringency of the resistance of TiN BEC. The experimental results help to optimize the process of TiN BEC, and SiN is recommended as a better choice as the linear layer.
Literature Review on Needs of Upper Limb Prosthesis Users
Cordella, Francesca; Ciancio, Anna Lisa; Sacchetti, Rinaldo; Davalli, Angelo; Cutti, Andrea Giovanni; Guglielmelli, Eugenio; Zollo, Loredana
2016-01-01
The loss of one hand can significantly affect the level of autonomy and the capability of performing daily living, working and social activities. The current prosthetic solutions contribute in a poor way to overcome these problems due to limitations in the interfaces adopted for controlling the prosthesis and to the lack of force or tactile feedback, thus limiting hand grasp capabilities. This paper presents a literature review on needs analysis of upper limb prosthesis users, and points out the main critical aspects of the current prosthetic solutions, in terms of users satisfaction and activities of daily living they would like to perform with the prosthetic device. The ultimate goal is to provide design inputs in the prosthetic field and, contemporary, increase user satisfaction rates and reduce device abandonment. A list of requirements for upper limb prostheses is proposed, grounded on the performed analysis on user needs. It wants to (i) provide guidelines for improving the level of acceptability and usefulness of the prosthesis, by accounting for hand functional and technical aspects; (ii) propose a control architecture of PNS-based prosthetic systems able to satisfy the analyzed user wishes; (iii) provide hints for improving the quality of the methods (e.g., questionnaires) adopted for understanding the user satisfaction with their prostheses. PMID:27242413
NASA Astrophysics Data System (ADS)
Zhu, Banghe; Rasmussen, John C.; Litorja, Maritoni; Sevick-Muraca, Eva M.
2017-03-01
All medical devices for Food and Drug market approval require specifications of performance based upon International System of Units (SI) or units derived from SI for reasons of traceability. Recently, near-infrared fluorescence (NIRF) imaging devices of a variety of designs have emerged on the market and in investigational clinical studies. Yet the design of devices used in the clinical studies vary widely, suggesting variable device performance. Device performance depends upon optimal excitation of NIRF imaging agents, rejection of backscattered excitation and ambient light, and selective collection of fluorescence emanating from the fluorophore. There remains no traceable working standards with SI units of radiance to enable prediction that a given molecular imaging agent can be detected in humans by a given NIRF imaging device. Furthermore, as technologies evolve and as NIRF imaging device components change, there remains no standardized means to track device improvements over time and establish clinical performance without involving clinical trials, often costly. In this study, we deployed a methodology to calibrate luminescent radiance of a stable, solid phantom in SI units of mW/cm2/sr for characterizing the measurement performance of ICCD and IsCMOS camera based NIRF imaging devices, such as signal-to-noise ratio (SNR) and contrast. The methodology allowed determination of superior SNR of the ICCD over the IsCMOS system; comparable contrast of ICCD and IsCMOS depending upon binning strategies.
16 CFR § 1750.5 - Detailed requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
... effects from spillage, cleaning, defrosting, and condensation. Devices shall be designed so that spillage... normal condensation will not so adversely affect the operation of the device as to result in its failure...
On the short circuit resilience of organic solar cells: prediction and validation.
Oostra, A Jolt; Smits, Edsger C P; de Leeuw, Dago M; Blom, Paul W M; Michels, Jasper J
2015-09-07
The operational characteristics of organic solar cells manufactured with large area processing methods suffers from the occurrence of short-circuits due to defects in the photoactive thin film stack. In this work we study the effect of a shunt resistance on an organic solar cell and demonstrate that device performance is not affected negatively as long as the shunt resistance is higher than approximately 1000 Ohm. By studying charge transport across PSS-lithium fluoride/aluminum (LiF/Al) shunting junctions we show that this prerequisite is already met by applying a sufficiently thick (>1.5 nm) LiF layer. We demonstrate that this remarkable shunt-resilience stems from the formation of a significant charge transport barrier at the PSS-LiF/Al interface. We validate our predictions by fabricating devices with deliberately severed photoactive layers and find an excellent agreement between the calculated and experimental current-voltage characteristics.
Highly repeatable nanoscale phase coexistence in vanadium dioxide films
NASA Astrophysics Data System (ADS)
Huffman, T. J.; Lahneman, D. J.; Wang, S. L.; Slusar, T.; Kim, Bong-Jun; Kim, Hyun-Tak; Qazilbash, M. M.
2018-02-01
It is generally believed that in first-order phase transitions in materials with imperfections, the formation of phase domains must be affected to some extent by stochastic (probabilistic) processes. The stochasticity would lead to unreliable performance in nanoscale devices that have the potential to exploit the transformation of physical properties in a phase transition. Here we show that stochasticity at nanometer length scales is completely suppressed in the thermally driven metal-insulator transition (MIT) in sputtered vanadium dioxide (V O2 ) films. The nucleation and growth of domain patterns of metallic and insulating phases occur in a strikingly reproducible way. The completely deterministic nature of domain formation and growth in films with imperfections is a fundamental and unexpected finding about the kinetics of this material. Moreover, it opens the door for realizing reliable nanoscale devices based on the MIT in V O2 and similar phase-change materials.
Titanium-based, fenestrated, in-plane microneedles for passive ocular drug delivery.
Khandan, Omid; Famili, Amin; Kahook, Malik Y; Rao, Masaru P
2012-01-01
Drug delivery to the eye remains a key challenge, due to limitations inherent to prevailing delivery techniques. For example, while topical delivery offers simplicity and safety, its efficacy is often limited by poor bioavailability, due to natural transport barriers and clearance mechanisms. Similarly, while intravitreal injections performed across the ocular tunic provide means for circumventing such limitations, non-negligible potential for retinal detachment and other complications adversely affects safety. Herein, we discuss our initial efforts to address these limitations through development of titanium-based microneedles (MNs) which seek to provide a safer, simpler, and more efficacious means of ocular drug delivery. Devices with in-plane geometry and through-thickness fenestrations that serve as drug reservoirs for passive delivery via diffusive transport from fast-dissolving coatings are demonstrated. Details regarding device design, fabrication, and mechanical testing are presented, as are results from preliminary coating characterization and insertion testing in ex vivo rabbit cornea.
An open circuit voltage decay system for performing injection dependent lifetime spectroscopy
NASA Astrophysics Data System (ADS)
Lacouture, Shelby; Schrock, James; Hirsch, Emily; Bayne, Stephen; O'Brien, Heather; Ogunniyi, Aderinto A.
2017-09-01
Of all of the material parameters associated with a semiconductor, the carrier lifetime is by far the most complex and dynamic, being a function of the dominant recombination mechanism, the equilibrium number of carriers, the perturbations in carriers (e.g., carrier injection), and the temperature, to name the most prominent variables. The carrier lifetime is one of the most important parameters in bipolar devices, greatly affecting conductivity modulation, on-state voltage, and reverse recovery. Carrier lifetime is also a useful metric for device fabrication process control and material quality. As it is such a dynamic quantity, carrier lifetime cannot be quoted in a general range such as mobility; it must be measured. The following describes a stand-alone, wide-injection range open circuit voltage decay system with unique lifetime extraction algorithms. The system is initially used along with various lifetime spectroscopy techniques to extract fundamental recombination parameters from a commercial high-voltage PIN diode.
Non-contact optical sensor for detection of glucose concentration using a magneto-optic effect
NASA Astrophysics Data System (ADS)
Ozana, Nisan; Beiderman, Yevgeny; Anand, Arun; Javidi, Baharam; Polani, Sagi; Schwarz, Ariel; Shemer, Amir; García, Javier; Zalevsky, Zeev
2016-03-01
In this paper we aim to experimentally verify a speckle based technique for non-contact measurement of glucose concentration in blood stream while the vision for the final device aims to contain a single wristwatch-style device containing an AC (alternating) electro-magnet generated by a solenoid, a laser and a camera. The experiments presented in work are performed in-vitro in order to verify the effects that are responsible for the operation principle. When a glucose substance is inserted into a solenoid generating an alternating magnetic field it exhibits Faraday rotation which affects the temporal changes of the secondary speckle patterns distribution. The temporal frequency resulting from the AC magnetic field was found to have a lock-in amplification role which increased the observability of the relatively small magneto-optic effect. Experimental results to support the proposed concept are presented.
Maffiodo, Daniela; De Nisco, Giuseppe; Gallo, Diego; Audenino, Alberto; Morbiducci, Umberto; Ferraresi, Carlo
2016-04-01
This work investigates the effect that the application of intermittent pneumatic compression to lower limbs has on the cardiovascular system. Intermittent pneumatic compression can be applied to subjects with reduced or null mobility and can be useful for therapeutic purposes in sports recovery, deep vein thrombosis prevention and lymphedema drainage. However, intermittent pneumatic compression performance and the effectiveness are often difficult to predict. This study presents a reduced-order numerical model of the interaction between the cardiovascular system and the intermittent pneumatic compression device. The effect that different intermittent pneumatic compression operating conditions have on the overall circulation is investigated. Our findings confirm (1) that an overall positive effect on hemodynamics can be obtained by properly applying the intermittent pneumatic compression device and (2) that using intermittent pneumatic compression for cardiocirculatory recovery is feasible in subjects affected by lower limb disease. © IMechE 2016.
Li, Xinying; Yu, Jianjun; Zhang, Junwen; Dong, Ze; Chi, Nan
2013-06-15
We experimentally demonstrate 2×56 Gb/s two-channel polarization-division-multiplexing quadrature-phase-shift-keying signal delivery over 80 km single-mode fiber-28 and 2 m Q-band (33-50 GHz) wireless link, adopting antenna horizontal- (H-) and vertical-polarization (V-polarization) multiplexing. At the wireless receiver, classic constant-modulus-algorithm equalization based on digital signal processing can realize polarization demultiplexing and remove the crosstalk at the same antenna polarization. By adopting antenna polarization multiplexing, the signal baud rate and performance requirements for optical and wireless devices can be reduced but at the cost of double antennas and devices, while wireless transmission capacity can also be increased but at the cost of stricter requirements for V-polarization. The isolation is only about 19 dB when V-polarization deviation approaches 10°, which will affect high-speed (>50 Gb/s) wireless delivery.
Evaluation of advanced cooling therapy's esophageal cooling device for core temperature control.
Naiman, Melissa; Shanley, Patrick; Garrett, Frank; Kulstad, Erik
2016-05-01
Managing core temperature is critical to patient outcomes in a wide range of clinical scenarios. Previous devices designed to perform temperature management required a trade-off between invasiveness and temperature modulation efficiency. The Esophageal Cooling Device, made by Advanced Cooling Therapy (Chicago, IL), was developed to optimize warming and cooling efficiency through an easy and low risk procedure that leverages heat transfer through convection and conduction. Clinical data from cardiac arrest, fever, and critical burn patients indicate that the Esophageal Cooling Device performs very well both in terms of temperature modulation (cooling rates of approximately 1.3°C/hour, warming of up to 0.5°C/hour) and maintaining temperature stability (variation around goal temperature ± 0.3°C). Physicians have reported that device performance is comparable to the performance of intravascular temperature management techniques and superior to the performance of surface devices, while avoiding the downsides associated with both.
Performance and breakdown characteristics of irradiated vertical power GaN P-i-N diodes
King, M. P.; Armstrong, A. M.; Dickerson, J. R.; ...
2015-10-29
Electrical performance and defect characterization of vertical GaN P-i-N diodes before and after irradiation with 2.5 MeV protons and neutrons is investigated. Devices exhibit increase in specific on-resistance following irradiation with protons and neutrons, indicating displacement damage introduces defects into the p-GaN and n- drift regions of the device that impact on-state device performance. The breakdown voltage of these devices, initially above 1700 V, is observed to decrease only slightly for particle fluence <; 10 13 cm -2. Furthermore, the unipolar figure of merit for power devices indicates that while the on-resistance and breakdown voltage degrade with irradiation, vertical GaNmore » P-i-Ns remain superior to the performance of the best available, unirradiated silicon devices and on-par with unirradiated modern SiC-based power devices.« less
Device Performance Capabilities | Photovoltaic Research | NREL
multijunction cells and modules. We use I-V measurement systems to assess the main performance parameters for PV cells and modules. I-V measurement systems determine the output performance of devices, including: open the device (η). Some I-V systems may also be used to perform dark I-V measurements to determine diode
Surface chemistry relevant to material processing for semiconductor devices
NASA Astrophysics Data System (ADS)
Okada, Lynne Aiko
Metal-oxide-semiconductor (MOS) structures are the core of many modern integrated circuit (IC) devices. Each material utilized in the different regions of the device has its own unique chemistry. Silicon is the base semiconductor material used in the majority of these devices. With IC device complexity increasing and device dimensions decreasing, understanding material interactions and processing becomes increasingly critical. Hsb2 desorption is the rate-limiting step in silicon growth using silane under low temperature conditions. Activation energies for Hsb2 desorption measured during Si chemical vapor deposition (CVD) versus single-crystal studies are found to be significantly lower. It has been proposed that defect sites on the silicon surface could explain the observed differences. Isothermal Hsb2 desorption studies using laser induced thermal desorption (LITD) techniques have addressed this issue. The growth of low temperature oxides is another relevant issue for fabrication of IC devices. Recent studies using 1,4-disilabutane (DSB) (SiHsb3CHsb2CHsb2SiHsb3) at 100sp°C in ambient Osb2 displayed the successful low temperature growth of silicon dioxide (SiOsb2). However, these studies provided no information about the deposition mechanism. We performed LITD and Fourier transform infrared (FTIR) studies on single-crystal and porous silicon surfaces to examine the adsorption, decomposition, and desorption processes to determine the deposition mechanism. Titanium nitride (TiN) diffusion barriers are necessary in modern metallization structures. Controlled deposition using titanium tetrachloride (TiClsb4) and ammonia (NHsb3) has been demonstrated using atomic layered processing (ALP) techniques. We intended to study the sequential deposition method by monitoring the surface intermediates using LITD techniques. However, formation of a Cl impurity source, ammonium chloride (NHsb4sp+Clsp-), was observed, thereby, limiting our ability for effective studies. Tetrakis(dimethylamino)titanium (Tilbrack N\\{CHsb3\\}sb2rbracksb4) (TDMAT) is another precursor used in the CVD deposition of TiN films in IC devices. Thermal decomposition studies have demonstrated deviations from conformal deposition. Successful conformal deposition may be affected by readsorption of the reaction product, dimethylamine (HNlbrack CHsb3rbracksb2). Detailed studies were performed using LITD techniques in order to understand the adsorption and desorption kinetics of TDMAT and dimethylamine to gain insights about the conformal deposition of TiN.
NASA Technical Reports Server (NTRS)
Hunt, W. D.; Brennan, K. F.; Summers, C. J.; Yun, Ilgu
1994-01-01
Reliability modeling and parametric yield prediction of GaAs/AlGaAs multiple quantum well (MQW) avalanche photodiodes (APDs), which are of interest as an ultra-low noise image capture mechanism for high definition systems, have been investigated. First, the effect of various doping methods on the reliability of GaAs/AlGaAs multiple quantum well (MQW) avalanche photodiode (APD) structures fabricated by molecular beam epitaxy is investigated. Reliability is examined by accelerated life tests by monitoring dark current and breakdown voltage. Median device lifetime and the activation energy of the degradation mechanism are computed for undoped, doped-barrier, and doped-well APD structures. Lifetimes for each device structure are examined via a statistically designed experiment. Analysis of variance shows that dark-current is affected primarily by device diameter, temperature and stressing time, and breakdown voltage depends on the diameter, stressing time and APD type. It is concluded that the undoped APD has the highest reliability, followed by the doped well and doped barrier devices, respectively. To determine the source of the degradation mechanism for each device structure, failure analysis using the electron-beam induced current method is performed. This analysis reveals some degree of device degradation caused by ionic impurities in the passivation layer, and energy-dispersive spectrometry subsequently verified the presence of ionic sodium as the primary contaminant. However, since all device structures are similarly passivated, sodium contamination alone does not account for the observed variation between the differently doped APDs. This effect is explained by the dopant migration during stressing, which is verified by free carrier concentration measurements using the capacitance-voltage technique.
fMRI-Compatible Electromagnetic Haptic Interface.
Riener, R; Villgrattner, T; Kleiser, R; Nef, T; Kollias, S
2005-01-01
A new haptic interface device is suggested, which can be used for functional magnetic resonance imaging (fMRI) studies. The basic component of this 1 DOF haptic device are two coils that produce a Lorentz force induced by the large static magnetic field of the MR scanner. A MR-compatible optical angular encoder and a optical force sensor enable the implementation of different control architectures for haptic interactions. The challenge was to provide a large torque, and not to affect image quality by the currents applied in the device. The haptic device was tested in a 3T MR scanner. With a current of up to 1A and a distance of 1m to the focal point of the MR-scanner it was possible to generate torques of up to 4 Nm. Within these boundaries image quality was not affected.
A study of charged particles/radiation damage to VLSI device materials
NASA Technical Reports Server (NTRS)
Okyere, John G.
1987-01-01
Future spacecraft systems such as the manned space station will be subjected to low-dose long term radiation particles. Most electronic systems are affected by such particles. There is therefore a great need to understand device physics and failure mechanisms affected by radiation and to design circuits that would be less susceptible to radiation. Using 2 MeV electron radiation and bias temperature aging, it was found that MOS capacitors that were prepositively biased have lower flatband voltage shift and lesser increase in density of surface state charge than those that were not prepositively biased. In addition, it was shown that there is continued recovery of flatband voltage and density of state charge in irradiated capacitors during both room temperature anneal and 137 degree anneal. When nMOS transistors were subjected to 1 MeV proton radiation, charge pumping and current versus voltage measurements indicated that transconductance degradation, threshold voltage shifts and changes in interface states density may be the primary cause of nMOS transistor failure after radiation. Simulation studies using SPICE were performed on CMOS SRAM cells of various transistor sizes. It is shown that transistor sizing affects the noise margins of CMOS SRAM cells, and that as the beta ratio of the transistors of the CMOS SRAM cell decreases, the effective noise margin of the SRAM cell increases. Some suggestions were made in connection with the design of CMOS SRAMS that are hardened against single event upsets.
Sirota, Benjamin; Glavin, Nicholas; Krylyuk, Sergiy; Davydov, Albert V; Voevodin, Andrey A
2018-06-06
Environmental and thermal stability of two-dimensional (2D) transition metal dichalcogenides (TMDs) remains a fundamental challenge towards enabling robust electronic devices. Few-layer 2H-MoTe 2 with an amorphous boron nitride (a-BN) covering layer was synthesized as a channel for back-gated field effect transistors (FET) and compared to uncovered MoTe 2 . A systematic approach was taken to understand the effects of heat treatment in air on the performance of FET devices. Atmospheric oxygen was shown to negatively affect uncoated MoTe 2 devices while BN-covered FETs showed considerably enhanced chemical and electronic characteristic stability. Uncapped MoTe 2 FET devices, which were heated in air for one minute, showed a polarity switch from n- to p-type at 150 °C, while BN-MoTe 2 devices switched only after 200 °C of heat treatment. Time-dependent experiments at 100 °C showed that uncapped MoTe 2 samples exhibited the polarity switch after 15 min of heat treatment while the BN-capped device maintained its n-type conductivity for the maximum 60 min duration of the experiment. X-ray photoelectron spectroscopy (XPS) analysis suggests that oxygen incorporation into MoTe 2 was the primary doping mechanism for the polarity switch. This work demonstrates the effectiveness of an a-BN capping layer in preserving few-layer MoTe 2 material quality and controlling its conductivity type at elevated temperatures in an atmospheric environment.
Wang, Lingyu; Yu, Linfen; Grist, Samantha; Cheung, Karen C; Chen, David D Y
2017-11-15
Cell culture systems based on polydimethylsiloxane (PDMS) microfluidic devices offer great flexibility because of their simple fabrication and adaptability. PDMS devices also make it straightforward to set up parallel experiments and can facilitate process automation, potentially speeding up the drug discovery process. However, cells grown in PDMS-based systems can develop in different ways to those grown with conventional culturing systems because of the differences in the containers' surfaces. Despite the growing number of studies on microfluidic cell culture devices, the differences in cellular behavior in PDMS-based devices and normal cell culture systems are poorly characterized. In this work, we investigated the proliferation and autophagy of MCF7 cells cultured in uncoated and Parylene-C coated PDMS wells. Using a quantitative method combining solid phase extraction and liquid chromatography mass spectrometry we developed, we showed that Tamoxifen uptake into the surfaces of uncoated PDMS wells can change the drug's effective concentration in the culture medium, affecting the results of Tamoxifen-induced autophagy and cytotoxicity assays. Such changes must be carefully analyzed before transferring in vitro experiments from a traditional culture environment to a PDMS-based microfluidic system. We also found that cells cultured in Parylene-C coated PDMS wells showed similar proliferation and drug response characteristics to cells cultured in standard polystyrene (PS) plates, indicating that Parylene-C deposition offers an easy way of limiting the uptake of small molecules into porous PDMS materials and significantly improves the performance of PDMS-based device for cell related research. Copyright © 2017 Elsevier B.V. All rights reserved.
Nickel-related adverse reactions in the treatment of cerebral aneurysms: a literature review.
Tsang, Anderson Chun On; Nicholson, Patrick; Pereira, Vitor Mendes
2018-04-20
Nickel is the most common metal allergen and predominantly affects women. It is also the ubiquitous component in the alloys used to manufacture intracranial devices for aneurysm treatments, including aneurysm clips, self-expanding stents, flow-diverting stents and endosaccular occlusion devices. Adverse events related to nickel-allergy after deployment of such devices are uncommon but can be severe, resulting in dilemmas in the choice of treatment strategies and devices in managing nickel-sensitive patients with intracranial aneurysms. A literature search in accordance with the PRISMA guidelines was performed to identify studies reporting on nickel-related adverse events in cerebral aneurysm treatment. The material of the culprit devices, clinical presentation, histological feature and treatment were reviewed. The clinical consideration and management options for nickel allergy patients were discussed. Nickel is a major component of the cobalt-alloy used in aneurysm clips, and of nitinol which is commonly used in flow-diverters and intracranial stents. There were 9 papers reporting 10 unique cases of nickel-related adverse events after aneurysm treatment. Half of the cases occurred after aneurysm clipping and the remaining 5 was attributed to endovascular devices. Two presented with dermatological and 8 with neurological manifestations including cerebral edema and cerebritis. Neurological complication related to nickel in cerebral aneurysm treatments is rare but remains a concern due to the high prevalence of nickel allergy in the population. Surgeons and interventionists should consider the metal-allergy history and its potential clinical significance in managing nickel-allergic patients with aneurysms. Copyright © 2018 Elsevier Inc. All rights reserved.
Zhang, Peng; Zhang, Wu; Wang, Junyong; Jiang, Kai; Zhang, Jinzhong; Li, Wenwu; Wu, Jiada; Hu, Zhigao; Chu, Junhao
2017-06-30
Active and widely controllable phase transition optical materials have got rapid applications in energy-efficient electronic devices, field of meta-devices and so on. Here, we report the optical properties of the vanadium dioxide (VO 2 )/aluminum-doped zinc oxide (Al:ZnO) hybrid n-n type heterojunctions and the corresponding electro-optic performances of the devices. Various structures are fabricated to compare the discrepancy of the optical and electrical characteristics. It was found that the reflectance spectra presents the wheel phenomenon rather than increases monotonically with temperature at near-infrared region range. The strong interference effects was found in the hybrid multilayer heterojunction. In addition, the phase transition temperature decreases with increasing the number of the Al:ZnO layer, which can be ascribed to the electron injection to the VO 2 film from the Al:ZnO interface. Affected by the double layer Al:ZnO, the abnormal Raman vibration mode was presented in the insulator region. By adding the external voltage on the Al 2 O 3 /Al:ZnO/VO 2 /Al:ZnO, Al 2 O 3 /Al:ZnO/VO 2 and Al 2 O 3 /VO 2 /Al:ZnO thin-film devices, the infrared optical spectra of the devices can be real-time manipulated by an external voltage. The main effect of joule heating and assistant effect of electric field are illustrated in this work. It is believed that the results will add a more thorough understanding in the application of the VO 2 /transparent conductive film device.
30 CFR 75.1714-3 - Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.
Code of Federal Regulations, 2010 CFR
2010-07-01
... devices by a person trained to perform such functions. (b) After each time a self-rescue device is worn or... person trained to perform this function. Self-rescue devices with broken seals or which are damaged so... accurate to within +1 gram. A device that weighs more than 10 grams over its original weight shall be...
Manycore Performance-Portability: Kokkos Multidimensional Array Library
Edwards, H. Carter; Sunderland, Daniel; Porter, Vicki; ...
2012-01-01
Large, complex scientific and engineering application code have a significant investment in computational kernels to implement their mathematical models. Porting these computational kernels to the collection of modern manycore accelerator devices is a major challenge in that these devices have diverse programming models, application programming interfaces (APIs), and performance requirements. The Kokkos Array programming model provides library-based approach to implement computational kernels that are performance-portable to CPU-multicore and GPGPU accelerator devices. This programming model is based upon three fundamental concepts: (1) manycore compute devices each with its own memory space, (2) data parallel kernels and (3) multidimensional arrays. Kernel executionmore » performance is, especially for NVIDIA® devices, extremely dependent on data access patterns. Optimal data access pattern can be different for different manycore devices – potentially leading to different implementations of computational kernels specialized for different devices. The Kokkos Array programming model supports performance-portable kernels by (1) separating data access patterns from computational kernels through a multidimensional array API and (2) introduce device-specific data access mappings when a kernel is compiled. An implementation of Kokkos Array is available through Trilinos [Trilinos website, http://trilinos.sandia.gov/, August 2011].« less
To twist, roll, stroke or poke? A study of input devices for menu navigation in the cockpit.
Stanton, Neville A; Harvey, Catherine; Plant, Katherine L; Bolton, Luke
2013-01-01
Modern interfaces within the aircraft cockpit integrate many flight management system (FMS) functions into a single system. The success of a user's interaction with an interface depends upon the optimisation between the input device, tasks and environment within which the system is used. In this study, four input devices were evaluated using a range of Human Factors methods, in order to assess aspects of usability including task interaction times, error rates, workload, subjective usability and physical discomfort. The performance of the four input devices was compared using a holistic approach and the findings showed that no single input device produced consistently high performance scores across all of the variables evaluated. The touch screen produced the highest number of 'best' scores; however, discomfort ratings for this device were high, suggesting that it is not an ideal solution as both physical and cognitive aspects of performance must be accounted for in design. This study evaluated four input devices for control of a screen-based flight management system. A holistic approach was used to evaluate both cognitive and physical performance. Performance varied across the dependent variables and between the devices; however, the touch screen produced the largest number of 'best' scores.
Results of a customer-based, post-market surveillance survey of the HeRO access device.
Fusselman, Maureen
2010-08-01
In order to supplement post-market surveillance data on the HeRO vascular access device, a non-scientific customer survey was conducted to obtain quantitative data from dialysis providers caring for patients implanted with the device. Dialysis nurses involved in the care of HeRO patients were contacted in order to obtain post-implant device performance information for 10% of patients implanted with the device at the time of the survey. Thirty-eight dialysis units with a total of 65 HeRO patients participated in the survey. The total duration of HeRO device use was 348.4 months with an average use of 5.4 months. Thirty-eight of the 65 HeRO patients (58.5%) were reported to not have experienced any performance issues. There were 28 device performance incidents reported for the remaining 27 patients included in the survey. Occlusion was the single most commonly reported device-related performance issue with 18 patients (27.7%) experiencing 25 occlusive episodes. The majority of the patients who had an occlusion (66.7%) only experienced one occlusive event. Infections occurred in 4 patients (6.2%) with an overall infection rate of 0.38 per 1,000 patient days. Post-market clinical experience during the first 18 months of commercialization of the HeRO device were in line with expectations based on the results from initial clinical studies with the device. Device occlusion remains the most commonly reported performance issue with the reported rate in this survey less than that which was reported in earlier published studies with the device.
NASA Technical Reports Server (NTRS)
Neudeck, P. G.; Huang, W.; Dudley, M.
1998-01-01
It is well-known that SiC wafer quality deficiencies are delaying the realization of outstandingly superior 4H-SiC power electronics. While efforts to date have centered on eradicating micropipes (i.e., hollow core super-screw dislocations with Burgers vector greater than 2c), 4H-SiC wafers and epilayers also contain elementary screw dislocations (i.e., Burgers vector = lc with no hollow core) in densities on the order of thousands per sq cm, nearly 100-fold micropipe densities. This paper describes an initial study into the impact of elementary screw dislocations on the reverse-bias current-voltage (I-V) characteristics of 4H-SiC p(+)n diodes. First, Synchrotron White Beam X-ray Topography (SWBXT) was employed to map the exact locations of elementary screw dislocations within small-area 4H-SiC p(+)n mesa diodes. Then the high-field reverse leakage and breakdown properties of these diodes were subsequently characterized on a probing station outfitted with a dark box and video camera. Most devices without screw dislocations exhibited excellent characteristics, with no detectable leakage current prior to breakdown, a sharp breakdown I-V knee, and no visible concentration of breakdown current. In contrast devices that contained at least one elementary screw dislocation exhibited a 5% to 35% reduction in breakdown voltage, a softer breakdown I-V knee, and visible microplasmas in which highly localized breakdown current was concentrated. The locations of observed breakdown microplasmas corresponded exactly to the locations of elementary screw dislocations identified by SWBXT mapping. While not as detrimental to SiC device performance as micropipes, the undesirable breakdown characteristics of elementary screw dislocations could nevertheless adversely affect the performance and reliability of 4H-SiC power devices.