NASA Technical Reports Server (NTRS)
Tellier, G. F.
1973-01-01
Tester investigates fundamental factors affecting cyclic life and sealing performance of valve seats and poppets. Tester provides for varying impact loading of poppet against seat and rate of cycling, and controls amount and type of relative motion between sealing faces of seat and poppet. Relative motion between seat and poppet can be varied in three modes.
Wöllner, Clemens; Hammerschmidt, David; Albrecht, Henning
2018-01-01
Slow motion scenes are ubiquitous in screen-based audiovisual media and are typically accompanied by emotional music. The strong effects of slow motion on observers are hypothetically related to heightened emotional states in which time seems to pass more slowly. These states are simulated in films and video clips, and seem to resemble such experiences in daily life. The current study investigated time perception and emotional response to media clips containing decelerated human motion, with or without music using psychometric and psychophysiological testing methods. Participants were presented with slow-motion scenes taken from commercial films, ballet and sports footage, as well as the same scenes converted to real-time. Results reveal that slow-motion scenes, compared to adapted real-time scenes, led to systematic underestimations of duration, lower perceived arousal but higher valence, lower respiration rates and smaller pupillary diameters. The presence of music compared to visual-only presentations strongly affected results in terms of higher accuracy in duration estimates, higher perceived arousal and valence, higher physiological activation and larger pupillary diameters, indicating higher arousal. Video genre affected responses in addition. These findings suggest that perceiving slow motion is not related to states of high arousal, but rather affects cognitive dimensions of perceived time and valence. Music influences these experiences profoundly, thus strengthening the impact of stretched time in audiovisual media.
Brian V. Smithers; Malcolm P. North; Constance I. Millar; Andrew M. Latimer
2017-01-01
In response to climate warming, subalpine treelines are expected to move up in elevation since treelines are generally controlled by growing season temperature. Where treeline is advancing, dispersal differences and early life stage environmental tolerances are likely to affect how species expand their ranges. Species with an establishment advantage will...
The effects of platform motion and target orientation on the performance of trackball manipulation.
Yau, Yi-Jan; Chao, Chin-Jung; Feng, Wen-Yang; Hwang, Sheue-Ling
2011-08-01
The trackball has been widely employed as a control/command input device on moving vehicles, but few studies have explored the effects of platform motion on its manipulation. Fewer still have considered this issue in designing the user interface and the arrangement of console location and orientation simultaneously. This work describes an experiment carried out to investigate the performance of trackball users on a simple point-and-click task in a motion simulator. By varying the orientation of onscreen targets, the effect of cursor movement direction on performance is investigated. The results indicate that the platform motion and target orientation both significantly affect the time required to point and click, but not the accuracy of target selection. The movement times were considerably longer under rolling and pitching motions and for targets located along the diagonal axes of the interface. Subjective evaluations carried out by the participants agree with these objective results. These findings could be used to optimise console and graphical menu design for use on maritime vessels. STATEMENT OF RELEVANCE: In military situations, matters of life or death may be decided in milliseconds. Any delay or error in classification and identification will thus affect the safety of the ship and its crew. This study demonstrates that performance of manipulating a trackball is affected by the platform motion and target orientation. The results of the present study can guide the arrangement of consoles and the design of trackball-based graphical user interfaces on maritime vessels.
[The human life cycle from a theoretical viewpoint].
Beier, W
1976-02-15
In the view of theoretical considerations the human course of life is regarded as a generalized motion. It is made an attempt to define terms, such as chronological age, biological age and ageing. In the model of ageing irreversible alterations affecting the organism are described by a complex variable, called vitality, which represents the state of systems. The rate of vitality dV/dt and the biomorphosis of systems are equivalent terms.
2007-01-01
laser cladding techniques. Customer: COMSUBPAC NAVSEASYSCOM Pearl Harbor Naval Shipyard...motion device to laser clad and re-dimension the affected tube to original specifications. Benefits: ° Reduce life cycle costs of tube...coatings via cold gas dynamic spraying and EB–PVD ° Spray-formed HT aluminum alloys ° Localized laser HT and cladding for wear
Ercan, Sabriye; Çetin, Cem; Yavuz, Turhan; Demir, Hilmi M; Atalay, Yurdagül B
2018-05-01
Objective The aim of this study was to observe the change of the ankle joint range of motion, the muscle strength values measured with an isokinetic dynamometer, pain scores, quality of life scale, and venous return time in chronic venous insufficiency diagnosed patients by prospective follow-up after 12-week exercise program including isokinetic exercises. Methods The patient group of this study comprised 27 patients (23 female, 4 male) who were diagnosed with chronic venous insufficiency. An exercise program including isokinetic exercise for the calf muscle was given to patients three days per week for 12 weeks. At the end of 12 weeks, five of the patients left the study due to inadequate compliance with the exercise program. As a result, control data of 22 patients were included. Ankle joint range of active motion, isokinetic muscle strength, pain, quality of life, and photoplethysmography measurements were assessed before starting and after the exercise program. Results Evaluating changes of the starting and control data depending on time showed that all isokinetic muscle strength measurement parameters, range of motion, and overall quality of life values of patients improved. Venous return time values have also increased significantly ( p < 0.05). Conclusion In conclusion, increase in muscle strength has been provided with exercise therapy in patients with chronic venous insufficiency. It has been determined that the increase in muscle strength affected the venous pump and this ensured improvement in venous function and range of motion of the ankle. In addition, it has been detected that pain reduced and quality of life improved after the exercise program.
The role of motion streaks in the perception of the kinetic Zollner illusion.
Khuu, Sieu K
2012-06-12
In classic geometric illusions such as the Zollner illusion, vertical lines superimposed on oriented background lines appear tilted in the direction opposite to the background. In kinetic forms of this illusion, an object moving over oriented background lines appears to follow a titled path, again in the direction opposite to the background. Existing literature does not proffer a complete explanation of the effect. Here, it is suggested that motion streaks underpin the illusion; that the effect is a consequence of interactions between detectors tuned to the orientation of background lines and those sensing the motion streaks that arise from fast object motion. This account was examined in the present study by measuring motion-tilt induction under different conditions in which the strength or salience of motion streaks was attenuated: by varying object speed (Experiment 1), contrast (Experiment 2), and trajectory/length by changing the element life-time within the stimulus (Experiment 3). It was predicted that, as motion streaks become less available, background lines would less affect the perceived direction of motion. Consistent with this prediction, the results indicated that, with a reduction in object speed below that required to generate motion streaks (< 1.12°/s), Weber contrast (< 0.125) and motion streak length (two frames) reduced or extinguished the motion-tilt-induction effect. The findings of the present study are consistent with previous reports and computational models that directly combine form and motion information to provide an effective determinant of motion direction.
Dreischarf, Marcel; Pries, Esther; Bashkuev, Maxim; Putzier, Michael; Schmidt, Hendrik
2016-03-21
The individual lumbar lordosis and lumbar motion have been identified to play an important role in pathogenesis of low back pain and are essential references for preoperative planning and postoperative evaluation. The clinical "gold-standard" for measuring lumbar lordosis and its motion are radiological "snap-shots" taken while standing and during upper-body flexion and extension. The extent to which these clinically assessed values characterise lumbar alignment and its motion in daily life merits discussion. A non-invasive measurement-system was employed to measure lumbar lordosis and lumbar motion in 208 volunteers (age: 20-74yrs; ♀/♂: 115/93). For an initial short-term measurement, comparable with the clinical "snap-shot", lumbar lordosis and its motion were assessed while standing and during flexion and extension. Subsequently, volunteers were released to their daily lives while wearing the device, and measurements were performed during the following 24h. The average lumbar lordosis during 24h (8.0°) differed significantly from the standardised measurement while standing (33.3°). Ranges of motion were significantly different throughout the day compared to standing measurements. The influence of the factors age and gender on lordosis and its motion resulted in conflicting results between long- and short-term-measurements. In conclusion, results of short-term examinations differ considerably from the average values during real-life. These findings might be important for surgical planning and increase the awareness of the biomechanical challenges that spinal structures and implants face in real-life. Furthermore, long-term assessments of spinal alignment and motion during daily life can provide valid data on spinal function and can reveal the importance of influential factors. Copyright © 2016 Elsevier Ltd. All rights reserved.
Lu, Hsuan-Lun; Lu, Tung-Wu; Lin, Hsiu-Chen; Chan, Wing P
2017-03-01
Treadmills have been used in rehabilitation settings to provide convenient protocols and continuous monitoring of movement over multiple cycles at well-controlled speeds for gait and balance training. However, the potential differences in the movement control may affect the translation of the training outcomes to real life over-ground walking (OW). The similarities and differences in the balance control between treadmill walking (TW) and OW have largely been unexplored. The current study bridged the gap by comparing the motions of the body's center of mass (COM) relative to the center of pressure (COP) between TW and OW, in terms of the COM-COP inclination angle (IA) and its rate of change (RCIA). The movement of the COM and COP separately were quite different between OW and TW, but when describing the COM motion relative to the COP, the COM motions became similar qualitatively with similar butterfly patterns. However, significantly increased peak values in themediolateral RCIA and greater ranges of mediolateral IA were found during TW (p<0.004). In the sagittal plane, the posterior velocity of the belt led to an anterior RCIA (posterior RCIA in OW) with increasing anterior IA during early double-limb support phase, and reduced posterior RCIA (p<0.009) with an increased anterior IA (p<0.001) during the remainder of the phase. These differences between TW and OW may have to be taken into account in future designs of strategies to optimize the translation of treadmill gait training outcomes into real life over-ground walking. Copyright © 2017. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Wang, Dong; Zhao, Yang; Yang, Fangfang; Tsui, Kwok-Leung
2017-09-01
Brownian motion with adaptive drift has attracted much attention in prognostics because its first hitting time is highly relevant to remaining useful life prediction and it follows the inverse Gaussian distribution. Besides linear degradation modeling, nonlinear-drifted Brownian motion has been developed to model nonlinear degradation. Moreover, the first hitting time distribution of the nonlinear-drifted Brownian motion has been approximated by time-space transformation. In the previous studies, the drift coefficient is the only hidden state used in state space modeling of the nonlinear-drifted Brownian motion. Besides the drift coefficient, parameters of a nonlinear function used in the nonlinear-drifted Brownian motion should be treated as additional hidden states of state space modeling to make the nonlinear-drifted Brownian motion more flexible. In this paper, a prognostic method based on nonlinear-drifted Brownian motion with multiple hidden states is proposed and then it is applied to predict remaining useful life of rechargeable batteries. 26 sets of rechargeable battery degradation samples are analyzed to validate the effectiveness of the proposed prognostic method. Moreover, some comparisons with a standard particle filter based prognostic method, a spherical cubature particle filter based prognostic method and two classic Bayesian prognostic methods are conducted to highlight the superiority of the proposed prognostic method. Results show that the proposed prognostic method has lower average prediction errors than the particle filter based prognostic methods and the classic Bayesian prognostic methods for battery remaining useful life prediction.
Research on a lubricating grease print process for cylindrical cylinder
NASA Astrophysics Data System (ADS)
Yang, Liu; Zhang, Xuan; Wang, XianYan; Tan, XiaoYan
2017-09-01
In vehicle braking system and clutch system of transmission, there is always a kind of cylindrical component dose reciprocating motion. The main working method is the reciprocating motion between the rubber sealing parts and cylindrical parts, the main factor affects the service life of the product is the lubricating performance of the moving parts. So the lubricating performance between cylinders and rubber sealing rings is particularly important, same as the quality of the grease applies on the surface of the surface of cylinder. Traditional method of manually applying grease has some defects such as applying unevenly, applying tools like brush and cloth easily falls off and affect the cleanness of products, contact skin easily cause allergy, waste grease due to the uncontrollable of grease quantity using in applying, low efficiency of manual operation. An automatic, quantitative and high pressure applying equipment is introduced in this document to replace the traditional manually applying method, which can guarantee the applying quality of the grease which are painted on the surface of cylinder and bring economic benefits to the company.
10 CFR 9.106 - Persons affected and motions for reconsideration.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Persons affected and motions for reconsideration. 9.106... Regulations § 9.106 Persons affected and motions for reconsideration. (a) Whenever any person whose interests.... (b) Any person may petition the Commission to reconsider its action under § 9.105(a) or paragraph (a...
Code of Federal Regulations, 2012 CFR
2012-01-01
... (d)(6) of this section. (c) Aliens eligible to reopen proceedings under section 1505(c) of the LIFE... LIFE Act Amendments, must establish that the alien: (1) Is prima facie eligible for suspension of... section 1505(c) of the LIFE Act Amendments. (1) An alien filing a motion to reopen proceedings pursuant to...
Code of Federal Regulations, 2013 CFR
2013-01-01
... (d)(6) of this section. (c) Aliens eligible to reopen proceedings under section 1505(c) of the LIFE... LIFE Act Amendments, must establish that the alien: (1) Is prima facie eligible for suspension of... section 1505(c) of the LIFE Act Amendments. (1) An alien filing a motion to reopen proceedings pursuant to...
Code of Federal Regulations, 2014 CFR
2014-01-01
... (d)(6) of this section. (c) Aliens eligible to reopen proceedings under section 1505(c) of the LIFE... LIFE Act Amendments, must establish that the alien: (1) Is prima facie eligible for suspension of... section 1505(c) of the LIFE Act Amendments. (1) An alien filing a motion to reopen proceedings pursuant to...
Wells, Stephen A; Crennell, Susan J; Danson, Michael J
2014-10-01
Citrate synthase (CS) catalyses the entry of carbon into the citric acid cycle and is highly-conserved structurally across the tree of life. Crystal structures of dimeric CSs are known in both "open" and "closed" forms, which differ by a substantial domain motion that closes the substrate-binding clefts. We explore both the static rigidity and the dynamic flexibility of CS structures from mesophilic and extremophilic organisms from all three evolutionary domains. The computational expense of this wide-ranging exploration is kept to a minimum by the use of rigidity analysis and rapid all-atom simulations of flexible motion, combining geometric simulation and elastic network modeling. CS structures from thermophiles display increased structural rigidity compared with the mesophilic enzyme. A CS structure from a psychrophile, stabilized by strong ionic interactions, appears to display likewise increased rigidity in conventional rigidity analysis; however, a novel modified analysis, taking into account the weakening of the hydrophobic effect at low temperatures, shows a more appropriate decreased rigidity. These rigidity variations do not, however, affect the character of the flexible dynamics, which are well conserved across all the structures studied. Simulation trajectories not only duplicate the crystallographically observed symmetric open-to-closed transitions, but also identify motions describing a previously unidentified antisymmetric functional motion. This antisymmetric motion would not be directly observed in crystallography but is revealed as an intrinsic property of the CS structure by modeling of flexible motion. This suggests that the functional motion closing the binding clefts in CS may be independent rather than symmetric and cooperative. © 2014 Wiley Periodicals, Inc.
Estimation of bio-signal based on human motion for integrated visualization of daily-life.
Umetani, Tomohiro; Matsukawa, Tsuyoshi; Yokoyama, Kiyoko
2007-01-01
This paper describes a method for the estimation of bio-signals based on human motion in daily life for an integrated visualization system. The recent advancement of computers and measurement technology has facilitated the integrated visualization of bio-signals and human motion data. It is desirable to obtain a method to understand the activities of muscles based on human motion data and evaluate the change in physiological parameters according to human motion for visualization applications. We suppose that human motion is generated by the activities of muscles reflected from the brain to bio-signals such as electromyograms. This paper introduces a method for the estimation of bio-signals based on neural networks. This method can estimate the other physiological parameters based on the same procedure. The experimental results show the feasibility of the proposed method.
Speed Biases With Real-Life Video Clips
Rossi, Federica; Montanaro, Elisa; de’Sperati, Claudio
2018-01-01
We live almost literally immersed in an artificial visual world, especially motion pictures. In this exploratory study, we asked whether the best speed for reproducing a video is its original, shooting speed. By using adjustment and double staircase methods, we examined speed biases in viewing real-life video clips in three experiments, and assessed their robustness by manipulating visual and auditory factors. With the tested stimuli (short clips of human motion, mixed human-physical motion, physical motion and ego-motion), speed underestimation was the rule rather than the exception, although it depended largely on clip content, ranging on average from 2% (ego-motion) to 32% (physical motion). Manipulating display size or adding arbitrary soundtracks did not modify these speed biases. Estimated speed was not correlated with estimated duration of these same video clips. These results indicate that the sense of speed for real-life video clips can be systematically biased, independently of the impression of elapsed time. Measuring subjective visual tempo may integrate traditional methods that assess time perception: speed biases may be exploited to develop a simple, objective test of reality flow, to be used for example in clinical and developmental contexts. From the perspective of video media, measuring speed biases may help to optimize video reproduction speed and validate “natural” video compression techniques based on sub-threshold temporal squeezing. PMID:29615875
Speed Biases With Real-Life Video Clips.
Rossi, Federica; Montanaro, Elisa; de'Sperati, Claudio
2018-01-01
We live almost literally immersed in an artificial visual world, especially motion pictures. In this exploratory study, we asked whether the best speed for reproducing a video is its original, shooting speed. By using adjustment and double staircase methods, we examined speed biases in viewing real-life video clips in three experiments, and assessed their robustness by manipulating visual and auditory factors. With the tested stimuli (short clips of human motion, mixed human-physical motion, physical motion and ego-motion), speed underestimation was the rule rather than the exception, although it depended largely on clip content, ranging on average from 2% (ego-motion) to 32% (physical motion). Manipulating display size or adding arbitrary soundtracks did not modify these speed biases. Estimated speed was not correlated with estimated duration of these same video clips. These results indicate that the sense of speed for real-life video clips can be systematically biased, independently of the impression of elapsed time. Measuring subjective visual tempo may integrate traditional methods that assess time perception: speed biases may be exploited to develop a simple, objective test of reality flow, to be used for example in clinical and developmental contexts. From the perspective of video media, measuring speed biases may help to optimize video reproduction speed and validate "natural" video compression techniques based on sub-threshold temporal squeezing.
Are visual peripheries forever young?
Burnat, Kalina
2015-01-01
The paper presents a concept of lifelong plasticity of peripheral vision. Central vision processing is accepted as critical and irreplaceable for normal perception in humans. While peripheral processing chiefly carries information about motion stimuli features and redirects foveal attention to new objects, it can also take over functions typical for central vision. Here I review the data showing the plasticity of peripheral vision found in functional, developmental, and comparative studies. Even though it is well established that afferent projections from central and peripheral retinal regions are not established simultaneously during early postnatal life, central vision is commonly used as a general model of development of the visual system. Based on clinical studies and visually deprived animal models, I describe how central and peripheral visual field representations separately rely on early visual experience. Peripheral visual processing (motion) is more affected by binocular visual deprivation than central visual processing (spatial resolution). In addition, our own experimental findings show the possible recruitment of coarse peripheral vision for fine spatial analysis. Accordingly, I hypothesize that the balance between central and peripheral visual processing, established in the course of development, is susceptible to plastic adaptations during the entire life span, with peripheral vision capable of taking over central processing.
Projectile motion in real-life situation: Kinematics of basketball shooting
NASA Astrophysics Data System (ADS)
Changjan, A.; Mueanploy, W.
2015-06-01
Basketball shooting is a basic practice for players. The path of the ball from the players to the hoop is projectile motion. For undergraduate introductory physics courses student must be taught about projectile motion. Basketball shooting can be used as a case study for learning projectile motion from real-life situation. In this research, we discuss the relationship between optimal angle, minimum initial velocity and the height of the ball before the player shoots the ball for basketball shooting problem analytically. We found that the value of optimal angle and minimum initial velocity decreases with increasing the height of the ball before the player shoots the ball.
Noise and range considerations for close-range radar sensing of life signs underwater.
Hafner, Noah; Lubecke, Victor
2011-01-01
Close-range underwater sensing of motion-based life signs can be performed with low power Doppler radar and ultrasound techniques. Corresponding noise and range performance trade-offs are examined here, with regard to choice of frequency and technology. The frequency range examined includes part of the UHF and microwave spectrum. Underwater detection of motion by radar in freshwater and saltwater are demonstrated. Radar measurements exhibited reduced susceptibility to noise as compared to ultrasound. While higher frequency radar exhibited better signal to noise ratio, propagation was superior for lower frequencies. Radar detection of motion through saltwater was also demonstrated at restricted ranges (1-2 cm) with low power transmission (10 dBm). The results facilitate the establishment of guidelines for optimal choice in technology for the underwater measurement motion-based life signs, with respect to trade offs involving range and noise.
Symons, J E; Hawkins, D A; Fyhrie, D P; Upadhyaya, S K; Stover, S M
2017-09-01
The metacarpophalangeal joint (fetlock) is the most commonly affected site of racehorse injury, with multiple observed pathologies consistent with extreme fetlock dorsiflexion. Race surface mechanics affect musculoskeletal structure loading and injury risk because surface forces applied to the hoof affect limb motions. Race surface mechanics are a function of controllable factors. Thus, race surface design has the potential to reduce the incidence of musculoskeletal injury through modulation of limb motions. However, the relationship between race surface mechanics and racehorse limb motions is unknown. To determine the effect of changing race surface and racehorse limb model parameters on distal limb motions. Sensitivity analysis of in silico fetlock motion to changes in race surface and racehorse limb parameters using a validated, integrated racehorse and race surface computational model. Fetlock motions were determined during gallop stance from simulations on virtual surfaces with differing average vertical stiffness, upper layer (e.g. cushion) depth and linear stiffness, horizontal friction, tendon and ligament mechanics, as well as fetlock position at heel strike. Upper layer depth produced the greatest change in fetlock motion, with lesser depths yielding greater fetlock dorsiflexion. Lesser fetlock changes were observed for changes in lower layer (e.g. base or pad) mechanics (nonlinear), as well as palmar ligament and tendon stiffness. Horizontal friction and fetlock position contributed less than 1° change in fetlock motion. Simulated fetlock motions are specific to one horse's anatomy reflected in the computational model. Anatomical differences among horses may affect the magnitude of limb flexion, but will likely have similar limb motion responses to varied surface mechanics. Race surface parameters affected by maintenance produced greater changes in fetlock motion than other parameters studied. Simulations can provide evidence to inform race surface design and management to reduce the incidence of injury. © 2017 EVJ Ltd.
Motion sickness prevalence in school children.
Henriques, Isadora Ferreira; Douglas de Oliveira, Dhelfeson Willya; Oliveira-Ferreira, Fernanda; Andrade, Peterson M O
2014-11-01
This study aimed to determine the prevalence of motion sickness in schoolchildren and related the finding to the postural balance and quality of life. A population-based cross-sectional study was carried out with 831 children aged 7 to 12 years. The frequency of motion sickness was evaluated based on the Motion Sickness Susceptibility Questionnaire-Short (MSSQ-short). Postural balance was assessed using the Romberg test under different sensory conditions. The Dizziness Handicap Inventory was used in order to assess the quality of life. The statistical analyses were performed using the chi-square, Kruskal-Wallis, Mann-Whitney, and Spearman correlation tests. The prevalence of motion sickness was 43.4 % in car, 43.2 % on bus, 11.7 % on park swing, and 11.6 % on Ferris wheel. Mean unadjusted scores on the MSSQ-short ranged from 5.0 (SE = 0.5) for 10-year-olds to 6.8 (SE = 0.5) for 9-year-olds. The most prevalent symptoms following the balance tests were dizziness (89.2 %), vertigo (54.9 %), headache (10.6 %), and nausea (8.2 %). Significant correlations were found between the MSSQ-short score and all postural balance tests. Significant correlations were found between the MSSQ and modified DHI (Dizziness Handicap Inventory) at all ages. The prevalence of motion sickness in schoolchildren is greater when in a car or on a bus. An association was found between motion sickness and postural balance tests and motion sickness and quality of life.
Relationships between clubshaft motions and clubface orientation during the golf swing.
Takagi, Tokio; Yokozawa, Toshiharu; Inaba, Yuki; Matsuda, Yuji; Shiraki, Hitoshi
2017-09-01
Since clubface orientation at impact affects ball direction and ball spin, the ability to control clubface orientation is one of the most important skills for golfers. This study presents a new method to describe clubface orientation as a function of the clubshaft motions (i.e., swing plane orientation, clubshaft angle in the swing plane, and clubshaft rolling angle) during a golf swing and investigates the relationships between the clubshaft motions and clubface orientation at impact. The club motion data of driver shots were collected from eight skilled golfers using a three-dimensional motion capture system. The degrees of influence of the clubshaft motions on the clubface orientation were investigated using sensitivity analysis. The sensitivity analysis revealed that the swing plane horizontal angle affected the clubface horizontal angle to an extent of 100%, that the clubshaft angle in the swing plane affected both the clubface vertical and horizontal angles to extents of 74 and 68%, respectively, and that the clubshaft rolling angle affected both the clubface vertical and horizontal angles to extents of -67 and 75%, respectively. Since the method presented here relates clubface orientation to clubshaft motions, it is useful for understanding the clubface control of a golfer.
Motion Pictures and Real-Life Violence; What the Research Says.
ERIC Educational Resources Information Center
Schramm, Wilbur
There is evidence that violence in motion pictures viewed by children on screen or television can contribute to violence in real life, although the movies can rarely be blamed as the sole cause of anti-social conduct. Clinical reports cite instances of the effect on "susceptible" youngsters; e.g., emotionally disturbed individuals. Long-term…
Design of Oil-Lubricated Machine for Life and Reliability
NASA Technical Reports Server (NTRS)
Zaretsky, Erwin V.
2007-01-01
In the post-World War II era, the major technology drivers for improving the life, reliability, and performance of rolling-element bearings and gears have been the jet engine and the helicopter. By the late 1950s, most of the materials used for bearings and gears in the aerospace industry had been introduced into use. By the early 1960s, the life of most steels was increased over that experienced in the early 1940s, primarily by the introduction of vacuum degassing and vacuum melting processes in the late 1950s. The development of elastohydrodynamic (EHD) theory showed that most rolling bearings and gears have a thin film separating the contacting bodies during motion and it is that film which affects their lives. Computer programs modeling bearing and gear dynamics that incorporate probabilistic life prediction methods and EHD theory enable optimization of rotating machinery based on life and reliability. With improved manufacturing and processing, the potential improvement in bearing and gear life can be as much as 80 times that attainable in the early 1950s. The work presented summarizes the use of laboratory fatigue data for bearings and gears coupled with probabilistic life prediction and EHD theories to predict the life and reliability of a commercial turboprop gearbox. The resulting predictions are compared with field data.
Visual/motion cue mismatch in a coordinated roll maneuver
NASA Technical Reports Server (NTRS)
Shirachi, D. K.; Shirley, R. S.
1981-01-01
The effects of bandwidth differences between visual and motion cueing systems on pilot performance for a coordinated roll task were investigated. Visual and motion cue configurations which were acceptable and the effects of reduced motion cue scaling on pilot performance were studied to determine the scale reduction threshold for which pilot performance was significantly different from full scale pilot performance. It is concluded that: (1) the presence or absence of high frequency error information in the visual and/or motion display systems significantly affects pilot performance; and (2) the attenuation of motion scaling while maintaining other display dynamic characteristics constant, affects pilot performance.
Altenbuchner, Amelie; Haug, Sonja; Kretschmer, Rainer; Weber, Karsten
2018-01-01
This preparatory study accelerates an implementation of individualized monitoring and feedback of physical motion using conventional motion trackers in the rehabilitation process of geriatric trauma patients. Regaining mobility is accompanied with improved quality of life in persons of very advanced age recovering from fragility fractures. Quantitative survey of regaining physical mobility provides recommendations for action on how to use motion trackers effectively in a clinical geriatric setting. Method mix of quantitative and qualitative interdisciplinary and mutual complementary research approaches (sociology, health research, philosophy/ethics, medical informatics, nursing science, gerontology and physical therapy). While validating motion tracker use in geriatric traumatology preliminary data are used to develop a target group oriented motion feedback. In addition measurement accuracy of a questionnaire about quality of life of multimorbid geriatric patients (FLQM) is tested. Implementing a new technology in a complex clinical setting needs to be based on a strong theoretical background but will not succeed without careful field testing.
Engstrand, Christina; Krevers, Barbro; Kvist, Joanna
2015-01-01
Prospective cohort study. The evidence of the relationship between functional recovery and impairment after surgery and hand therapy are inconsistent. To explore factors that were most related to functional recovery as measured by DASH in patients with Dupuytren's disease. Eighty-one patients undergoing surgery and hand therapy were consecutively recruited. Functional recovery was measured by the Disability of the Arm, Shoulder and Hand (DASH) questionnaire. Explanatory variables: range of motion of the finger joints, five questions regarding safety and social issues of hand function, and health-related quality of life (Euroqol). The three variables "need to take special precautions", "avoid using the hand in social context", and health-related quality of life (EQ-5D index) explained 62.1% of the variance in DASH, where the first variable had the greatest relative effect. Safety and social issues of hand function and quality of life had an evident association with functional recovery. IV. Copyright © 2015 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.
An upper limb robot model of children limb for cerebral palsy neurorehabilitation.
Pathak, Yagna; Johnson, Michelle
2012-01-01
Robot therapy has emerged in the last few decades as a tool to help patients with neurological injuries relearn motor tasks and improve their quality of life. The main goal of this study was to develop a simple model of the human arm for children affected with cerebral palsy (CP). The Simulink based model presented here shows a comparison for children with and without disabilities (ages 6-15) with normal and reduced range of motion in the upper limb. The model incorporates kinematic and dynamic considerations required for activities of daily living. The simulation was conducted using Matlab/Simulink and will eventually be integrated with a robotic counterpart to develop a physical robot that will provide assistance in activities of daily life (ADLs) to children with CP while also aiming to improve motor recovery.
Coherent modulation of stimulus colour can affect visually induced self-motion perception.
Nakamura, Shinji; Seno, Takeharu; Ito, Hiroyuki; Sunaga, Shoji
2010-01-01
The effects of dynamic colour modulation on vection were investigated to examine whether perceived variation of illumination affects self-motion perception. Participants observed expanding optic flow which simulated their forward self-motion. Onset latency, accumulated duration, and estimated magnitude of the self-motion were measured as indices of vection strength. Colour of the dots in the visual stimulus was modulated between white and red (experiment 1), white and grey (experiment 2), and grey and red (experiment 3). The results indicated that coherent colour oscillation in the visual stimulus significantly suppressed the strength of vection, whereas incoherent or static colour modulation did not affect vection. There was no effect of the types of the colour modulation; both achromatic and chromatic modulations turned out to be effective in inhibiting self-motion perception. Moreover, in a situation where the simulated direction of a spotlight was manipulated dynamically, vection strength was also suppressed (experiment 4). These results suggest that observer's perception of illumination is critical for self-motion perception, and rapid variation of perceived illumination would impair the reliabilities of visual information in determining self-motion.
Motion Correction in PROPELLER and Turboprop-MRI
Tamhane, Ashish A.; Arfanakis, Konstantinos
2009-01-01
PROPELLER and Turboprop-MRI are characterized by greatly reduced sensitivity to motion, compared to their predecessors, fast spin-echo and gradient and spin-echo, respectively. This is due to the inherent self-navigation and motion correction of PROPELLER-based techniques. However, it is unknown how various acquisition parameters that determine k-space sampling affect the accuracy of motion correction in PROPELLER and Turboprop-MRI. The goal of this work was to evaluate the accuracy of motion correction in both techniques, to identify an optimal rotation correction approach, and determine acquisition strategies for optimal motion correction. It was demonstrated that, blades with multiple lines allow more accurate estimation of motion than blades with fewer lines. Also, it was shown that Turboprop-MRI is less sensitive to motion than PROPELLER. Furthermore, it was demonstrated that the number of blades does not significantly affect motion correction. Finally, clinically appropriate acquisition strategies that optimize motion correction were discussed for PROPELLER and Turboprop-MRI. PMID:19365858
Barfod, Kristoffer Weisskirchner; Hansen, Maria Swennergren; Holmich, Per; Troelsen, Anders; Kristensen, Morten Tange
2016-11-29
Early controlled ankle motion is widely used in the non-operative treatment of acute Achilles tendon rupture, though its safety and efficacy have never been investigated in a randomized setup. The objectives of this study are to investigate if early controlled motion of the ankle affects functional and patient-reported outcomes. The study is performed as a blinded, randomized, controlled trial with patients allocated in a 1:1 ratio to one of two parallel groups. Patients aged from 18 to 70 years are eligible for inclusion. The intervention group performs early controlled motion of the ankle in weeks 3-8 after rupture. The control group is immobilized. In total, 130 patients will be included from one big orthopedic center over a period of 2½ years. The primary outcome is the patient-reported Achilles tendon Total Rupture Score evaluated at 12 months post-injury. Secondary outcome measures are the heel-rise work test, Achilles tendon elongation, and the rate of re-rupture. The primary analysis will be conducted as intention-to-treat analyses. This trial is the first to investigate the safety and efficacy of early controlled motion in the treatment of acute Achilles tendon rupture in a randomized setup. The study uses the patient-reported outcome measure, the Achilles tendon Total Rupture Score, as the primary endpoint, as it is believed to be the best surrogate measure for the tendon's actual capability to function in everyday life. ClinicalTrials.gov: NCT02015364 . Registered on 13 December 2013.
17 CFR 10.26 - Motions and other papers.
Code of Federal Regulations, 2011 CFR
2011-04-01
... procedural orders. Motions for procedural orders, including motions for extension of time, may be acted on at any time, without awaiting a response thereto. Any party adversely affected by such order may request reconsideration, vacation or modification of the order. (d) Dilatory motions. Repetitive or numerous motions...
17 CFR 10.26 - Motions and other papers.
Code of Federal Regulations, 2010 CFR
2010-04-01
... procedural orders. Motions for procedural orders, including motions for extension of time, may be acted on at any time, without awaiting a response thereto. Any party adversely affected by such order may request reconsideration, vacation or modification of the order. (d) Dilatory motions. Repetitive or numerous motions...
Fluid Flow in An Evaporating Droplet
NASA Technical Reports Server (NTRS)
Hu, H.; Larson, R.
1999-01-01
Droplet evaporation is a common phenomenon in everyday life. For example, when a droplet of coffee or salt solution is dropped onto a surface and the droplet dries out, a ring of coffee or salt particles is left on the surface. This phenomenon exists not only in everyday life, but also in many practical industrial processes and scientific research and could also be used to assist in DNA sequence analysis, if the flow field in the droplet produced by the evaporation could be understood and predicted in detail. In order to measure the fluid flow in a droplet, small particles can be suspended into the fluid as tracers. From the ratio of gravitational force to Brownian force a(exp 4)(delta rho)(g)/k(sub B)T, we find that particle's tendency to settle is proportional to a(exp 4) (a is particle radius). So, to keep the particles from settling, the droplet size should be chosen to be in a range 0.1 -1.0 microns in experiments. For such small particles, the Brownian force will affect the motion of the particle preventing accurate measurement of the flow field. This problem could be overcome by using larger particles as tracers to measure fluid flow under microgravity since the gravitational acceleration g is then very small. For larger particles, Brownian force would hardly affect the motion of the particles. Therefore, accurate flow field could be determined from experiments in microgravity. In this paper, we will investigate the fluid flow in an evaporating droplet under normal gravity, and compare experiments to theories. Then, we will present our ideas about the experimental measurement of fluid flow in an evaporating droplet under microgravity.
Martins da Silva, Renata Cristina; Rezende, Laura Ferreira
2014-01-01
Breast cancer is the second most common malignancy among women. Surgical and supplemental (or adjuvant) therapies to combat the disease may implicate physical functional consequences for the ipsilateral upper extremity. These dysfunctions may persist for many years and have repercussions on the performance of daily living activities. The aim of this study was to assess the impact of physical functional disabilities on quality of life in women after breast cancer surgery. Eighty-two women in the postoperative period of conservative surgery for breast cancer participated in the study. Axillary lymph node dissection was performed in all patients and mean time since surgery was 5.78 (± 4.60) years. The women responded to a questionnaire to assess quality of life (FACT-B) and to another to assess functional capacity (QuickDASH). They were then referred to physical therapy examination to measure shoulder range of motion (flexion, abduction and external rotation) and arm volume. Range of motion in the ipsilateral shoulder was limited: shoulder flexion range of motion reached a mean value of 155.44º (± 28.31), mean abduction was 149.05º (± 29.51), and mean external shoulder rotation was 58.44º (± 29.17). These limitations had a negative impact on functional capacity and global quality of life. Lymphedema was present in 28.04% of women assessed and did not impair quality of life or functional capacity. Physical functional disabilities were present in the late postoperative period of breast cancer survivors and limited shoulder range of motion negatively influenced their functional capacity and quality of life. The presence of lymphedema did not impair functional capacity or quality of life in the postoperative period.
NASA Astrophysics Data System (ADS)
Šprem, Jurica; de Vos, Bob D.; de Jong, Pim A.; Viergever, Max A.; Išgum, Ivana
2017-02-01
Coronary artery calcification (CAC) is a strong and independent predictor of cardiovascular events (CVEs). CAC can be quantified in chest CT scans acquired in lung screening. However, in these images the reproducibility of CAC quantification is compromised by cardiac motion that occurs during scanning, thereby limiting the reproducibility of CVE risk assessment. We present a system for the identification of CACs strongly affected by cardiac motion artifacts by using a convolutional neural network (CNN). This study included 125 chest CT scans from the National Lung Screening Trial (NLST). Images were acquired with CT scanners from four different vendors (GE, Siemens, Philips, Toshiba) with varying tube voltage, image resolution settings, and without ECG synchronization. To define the reference standard, an observer manually identified CAC lesions and labeled each according to the presence of cardiac motion: strongly affected (positive), mildly affected/not affected (negative). A CNN was designed to automatically label the identified CAC lesions according to the presence of cardiac motion by analyzing a patch from the axial CT slice around each lesion. From 125 CT scans, 9201 CAC lesions were analyzed. 8001 lesions were used for training (19% positive) and the remaining 1200 (50% positive) were used for testing. The proposed CNN achieved a classification accuracy of 85% (86% sensitivity, 84% specificity). The obtained results demonstrate that the proposed algorithm can identify CAC lesions that are strongly affected by cardiac motion. This could facilitate further investigation into the relation of CAC scoring reproducibility and the presence of cardiac motion artifacts.
The upper spatial limit for perception of displacement is affected by preceding motion.
Stefanova, Miroslava; Mateeff, Stefan; Hohnsbein, Joachim
2009-03-01
The upper spatial limit D(max) for perception of apparent motion of a random dot pattern may be strongly affected by another, collinear, motion that precedes it [Mateeff, S., Stefanova, M., &. Hohnsbein, J. (2007). Perceived global direction of a compound of real and apparent motion. Vision Research, 47, 1455-1463]. In the present study this phenomenon was studied with two-dimensional motion stimuli. A random dot pattern moved alternately in the vertical and oblique direction (zig-zag motion). The vertical motion was of 1.04 degrees length; it was produced by three discrete spatial steps of the dots. Thereafter the dots were displaced by a single spatial step in oblique direction. Each motion lasted for 57ms. The upper spatial limit for perception of the oblique motion was measured under two conditions: the vertical component of the oblique motion and the vertical motion were either in the same or in opposite directions. It was found that the perception of the oblique motion was strongly influenced by the relative direction of the vertical motion that preceded it; in the "same" condition the upper spatial limit was much shorter than in the "opposite" condition. Decreasing the speed of the vertical motion reversed this effect. Interpretations based on networks of motion detectors and on Gestalt theory are discussed.
The Thomas A. Edison Papers at Rutgers University
Contact Us Research Digital Edition Microfilm Edition Book Edition Motion Picture Catalogs Document Microfilm Edition Book Edition Motion Picture Catalogs Document Sampler Thomas Edison's Life Biography
Expressions of Different-Trajectory Caused Motion Events in Chinese
ERIC Educational Resources Information Center
Paul, Jing Z.
2013-01-01
We perform motion events in all aspects of our daily life, from walking home to jumping into a pool, from throwing a frisbee to pushing a shopping cart. The fact that languages may encode such motion events in different fashions has raised intriguing questions regarding the typological classifications of natural languages in relation to…
Aristotle, Motion, and Rhetoric.
ERIC Educational Resources Information Center
Sutton, Jane
Aristotle rejects a world vision of changing reality as neither useful nor beneficial to human life, and instead he reaffirms both change and eternal reality, fuses motion and rest, and ends up with "well-behaved" changes. This concept of motion is foundational to his world view, and from it emerges his theory of knowledge, philosophy of…
The Reproduction of Scientific Understanding about Pendulum Motion in the Public
ERIC Educational Resources Information Center
Manabu, Sumida
2004-01-01
This paper describes life-span development of understanding about pendulum motion and effects of school science. The subjects were 2,766 people ranging from kindergartners up to 88 years senior citizens. The conflict and consensus between children and their parent's understanding of pendulum motion were also analyzed. The kindergartner's…
78 FR 57570 - Safety Zone; Motion Picture Production; Chicago, Illinois
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-19
...-AA00 Safety Zone; Motion Picture Production; Chicago, Illinois AGENCY: Coast Guard, DHS. ACTION: Notice... motion picture filming in Calumet Harbor, Chicago, IL from 9 p.m. until 6 a.m., from September 15 through September 29, 2013. This action is necessary and intended to ensure safety of life on navigable waters...
Celebi, M.; Bazzurro, P.; Chiaraluce, L.; Clemente, P.; Decanini, L.; Desortis, A.; Ellsworth, W.; Gorini, A.; Kalkan, E.; Marcucci, S.; Milana, G.; Mollaioli, F.; Olivieri, M.; Paolucci, R.; Rinaldis, D.; Rovelli, A.; Sabetta, F.; Stephens, C.
2010-01-01
The normal-faulting earthquake of 6 April 2009 in the Abruzzo Region of central Italy caused heavy losses of life and substantial damage to centuriesold buildings of significant cultural importance and to modern reinforcedconcrete- framed buildings with hollow masonry infill walls. Although structural deficiencies were significant and widespread, the study of the characteristics of strong motion data from the heavily affected area indicated that the short duration of strong shaking may have spared many more damaged buildings from collapsing. It is recognized that, with this caveat of shortduration shaking, the infill walls may have played a very important role in preventing further deterioration or collapse of many buildings. It is concluded that better new or retrofit construction practices that include reinforcedconcrete shear walls may prove helpful in reducing risks in such seismic areas of Italy, other Mediterranean countries, and even in United States, where there are large inventories of deficient structures. ?? 2010, Earthquake Engineering Research Institute.
Long-term effects of antepartum bed rest on offspring.
Bellieni, Carlo Valerio; Bagnoli, Franco; Perrone, Serafina; Caparelli, Ninetta; Cordelli, Duccio Maria; Melissa, Bernardino; Buonocore, Giuseppe
2003-01-01
We studied the children of mothers who were confined to bed during pregnancy for more than 15 consecutive days (mean 3.69 months) in the years 1986-1990 (bed rest offspring; BRO). We studied 86 children: 43 BRO and 43 control children. Data were obtained by means of a 20-item questionnaire filled in by the mothers. The BRO group differed from the control group in incidence of allergies (p = 0.005), motion sickness (p = 0.03), and need to be rocked to fall asleep (p = 0.01). More BRO born at term than controls played musical instruments later in life. Two possible explanations for more allergies among the BRO group are the use of beta-stimulating drugs against premature delivery and the effects of prolonged stress on the developing immune system. Understimulation of the developing vestibular system during gestation may affect some aspects of its development and may explain the higher incidence of motion sickness and need for vigorous rocking in BRO. Copyright 2003 S. Karger AG, Basel
Modification of hemiplegic compensatory gait pattern by symmetry-based motion controller of HAL.
Kawamoto, Hiroaki; Kadone, Hideki; Sakurai, Takeru; Sankai, Yoshiyuki
2015-01-01
As one of several characteristics of hemiplegic patients after stroke, compensatory gait caused by affected limb is often seen. The purpose of this research is to apply a symmetry-based controller of a wearable type lower limb robot, Hybrid Assistive Limb (HAL) to hemiplegic patients with compensatory gait, and to investigate improvement of gait symmetry. The controller is designed respectively for swing phase and support phase according to characteristics of hemiplegic gait pattern. The controller during swing phase stores the motion of the unaffected limb and then provides motion support on the affected limb during the subsequent swing using the stored pattern to realize symmetric gait based on spontaneous limb swing. Moreover, the controller during support phase provides motion to extend hip and knee joints to support wearer's body. Clinical tests were conducted in order to assess the modification of gait symmetry. Our case study involved participation of one chronic stroke patient who performs abnormally-compensatory gait for both of the affected and unaffected limbs. As a result, the patient's gait symmetry was improved by providing motion support during the swing phase on the affected side and motion constraint during the support phase on the unaffected side. The study showed promising basis for the effectiveness of the controller for the future clinical study.
Tamhane, Ashish A; Arfanakis, Konstantinos
2009-07-01
Periodically-rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) and Turboprop MRI are characterized by greatly reduced sensitivity to motion, compared to their predecessors, fast spin-echo (FSE) and gradient and spin-echo (GRASE), respectively. This is due to the inherent self-navigation and motion correction of PROPELLER-based techniques. However, it is unknown how various acquisition parameters that determine k-space sampling affect the accuracy of motion correction in PROPELLER and Turboprop MRI. The goal of this work was to evaluate the accuracy of motion correction in both techniques, to identify an optimal rotation correction approach, and determine acquisition strategies for optimal motion correction. It was demonstrated that blades with multiple lines allow more accurate estimation of motion than blades with fewer lines. Also, it was shown that Turboprop MRI is less sensitive to motion than PROPELLER. Furthermore, it was demonstrated that the number of blades does not significantly affect motion correction. Finally, clinically appropriate acquisition strategies that optimize motion correction are discussed for PROPELLER and Turboprop MRI. (c) 2009 Wiley-Liss, Inc.
ERIC Educational Resources Information Center
MOSAIC, 1977
1977-01-01
Explores possibility of extra-terrestrial life, reviewing current hypotheses regarding where in space life would most likely occur. Discusses astrometry and spectroscopy as methods for determining stellar motions. Describes United States and Soviet projects for receiving stellar communications. Relates origin of life on earth to observed high…
A matter of motion or an emotional matter? Management of depression in Parkinson's disease.
Lagopoulos, Jim; Malhi, Gin S; Ivanovski, Belinda; Cahill, Catherine M; Morris, John G L
2005-11-01
Depression is one of the most frequent comorbidities occurring in Parkinson's disease, affecting up to 50% of patients. Depression is associated with severe negative symptoms and has been shown to contribute to an increased rate of decline of both cognitive and motor function, profoundly impacting on the patient's quality of life. The symptoms of depression overlap with the motor features of Parkinson's disease, making detection difficult. Moreover, the lack of specialized screening tools means that depression remains undiagnosed and untreated in a high percentage of patients. However, depression in Parkinson's disease, when identified early, can be effectively treated with a variety of antidepressant medications, improving quality of life and preserving daily function. The focus of this review is to provide an overview of current knowledge regarding depression in Parkinson's disease, followed by a practical discussion addressing the issues of the detection, diagnosis and treatment.
NASA Technical Reports Server (NTRS)
Rizzi, Stephen A.; Behnke, marlana N.; Przekop, Adam
2010-01-01
High-cycle fatigue of an elastic-plastic beam structure under the combined action of thermal and high-intensity non-Gaussian acoustic loadings is considered. Such loadings can be highly damaging when snap-through motion occurs between thermally post-buckled equilibria. The simulated non-Gaussian loadings investigated have a range of skewness and kurtosis typical of turbulent boundary layer pressure fluctuations in the vicinity of forward facing steps. Further, the duration and steadiness of high excursion peaks is comparable to that found in such turbulent boundary layer data. Response and fatigue life estimates are found to be insensitive to the loading distribution, with the minor exception of cases involving plastic deformation. In contrast, the fatigue life estimate was found to be highly affected by a different type of non-Gaussian loading having bursts of high excursion peaks.
Biological Motion Primes the Animate/Inanimate Distinction in Infancy
Poulin-Dubois, Diane; Crivello, Cristina; Wright, Kristyn
2015-01-01
Given that biological motion is both detected and preferred early in life, we tested the hypothesis that biological motion might be instrumental to infants’ differentiation of animate and inanimate categories. Infants were primed with either point-light displays of realistic biological motion, random motion, or schematic biological motion of an unfamiliar shape. After being habituated to these displays, 12-month-old infants categorized animals and vehicles as well as furniture and vehicles with the sequential touching task. The findings indicated that infants primed with point-light displays of realistic biological motion showed better categorization of animates than those exposed to random or schematic biological motion. These results suggest that human biological motion might be one of the motion cues that provide the building blocks for infants’ concept of animacy. PMID:25659077
The influence of ship motion of manual control skills
NASA Technical Reports Server (NTRS)
Mcleod, P.; Poulton, C.; Duross, H.; Lewis, W.
1981-01-01
The effects of ship motion on a range of typical manual control skills were examined on the Warren Spring ship motion simulator driven in heave, pitch, and roll by signals taken from the frigate HMS Avenger at 13 m/s (25 knots) into a force 4 wind. The motion produced a vertical r.m.s. acceleration of 0.024g, mostly between 0.1 and 0.3 Hz, with comparatively little pitch or roll. A task involving unsupported arm movements was seriously affected by the motion; a pursuit tracking task showed a reliable decrement although it was still performed reasonably well (pressure and free moving tracking controls were affected equally by the motion); a digit keying task requiring ballistic hand movements was unaffected. There was no evidence that these effects were caused by sea sickness. The differing response to motion of the different tasks, from virtual destruction to no effect, suggests that a major benefit could come from an attempt to design the man/control interface onboard ship around motion resistant tasks.
Multimodal Pilot Behavior in Multi-Axis Tracking Tasks with Time-Varying Motion Cueing Gains
NASA Technical Reports Server (NTRS)
Zaal, P. M. T; Pool, D. M.
2014-01-01
In a large number of motion-base simulators, adaptive motion filters are utilized to maximize the use of the available motion envelope of the motion system. However, not much is known about how the time-varying characteristics of such adaptive filters affect pilots when performing manual aircraft control. This paper presents the results of a study investigating the effects of time-varying motion filter gains on pilot control behavior and performance. An experiment was performed in a motion-base simulator where participants performed a simultaneous roll and pitch tracking task, while the roll and/or pitch motion filter gains changed over time. Results indicate that performance increases over time with increasing motion gains. This increase is a result of a time-varying adaptation of pilots' equalization dynamics, characterized by increased visual and motion response gains and decreased visual lead time constants. Opposite trends are found for decreasing motion filter gains. Even though the trends in both controlled axes are found to be largely the same, effects are less significant in roll. In addition, results indicate minor cross-coupling effects between pitch and roll, where a cueing variation in one axis affects the behavior adopted in the other axis.
NASA Astrophysics Data System (ADS)
Michioka, Takenobu; Sato, Ayumu; Sada, Koichi
2011-10-01
Large-scale turbulent motions enhancing horizontal gas spread in an atmospheric boundary layer are simulated in a wind-tunnel experiment. The large-scale turbulent motions can be generated using an active grid installed at the front of the test section in the wind tunnel, when appropriate parameters for the angular deflection and the rotation speed are chosen. The power spectra of vertical velocity fluctuations are unchanged with and without the active grid because they are strongly affected by the surface. The power spectra of both streamwise and lateral velocity fluctuations with the active grid increase in the low frequency region, and are closer to the empirical relations inferred from field observations. The large-scale turbulent motions do not affect the Reynolds shear stress, but change the balance of the processes involved. The relative contributions of ejections to sweeps are suppressed by large-scale turbulent motions, indicating that the motions behave as sweep events. The lateral gas spread is enhanced by the lateral large-scale turbulent motions generated by the active grid. The large-scale motions, however, do not affect the vertical velocity fluctuations near the surface, resulting in their having a minimal effect on the vertical gas spread. The peak concentration normalized using the root-mean-squared value of concentration fluctuation is remarkably constant over most regions of the plume irrespective of the operation of the active grid.
Liu, Guanlin; Leng, Qiang; Lian, Jiawei; Guo, Hengyu; Yi, Xi; Hu, Chenguo
2015-01-21
Great attention has been paid to nanogenerators that harvest energy from ambient environments lately. In order to give considerable output current, most nanogenerators require high-velocity motion that in most cases can hardly be provided in our daily life. Here we report a notepad-like triboelectric generator (NTEG), which uses simple notepad-like structure to generate elastic deformation so as to turn a low-velocity kinetic energy into high-velocity kinetic energy through the conversion of elastic potential energy. Therefore, the NTEG can achieve high current output under low-velocity motion, which completely distinguishes it from tribogenerators previously reported. The factors that may affect the output performance are explored, including the number of slices, active length of slice, press speed, and vertical displacement. In addition, the working mechanism is systematically studied, indicating that the efficiency of the generator can be greatly enhanced by interconversion between kinetic energy and elastic potential energy. The short-circuit current, the open-circuit voltage, and power density are 205 μA and 470 V and 9.86 W/m(2), respectively, which is powerful enough to light up hundreds of light-emitting diodes (LEDs) and charge a commercial capacitor. Besides, NTEGs have been successfully applied to a self-powered door monitor.
Piezoelectric actuator uses sequentially-excited multiple elements: A concept
NASA Technical Reports Server (NTRS)
Sabelman, E. E.
1972-01-01
Utilizing arrays of sequentially-excited piezoelectric elements to provide motion in a nonmagnetic motor provide built-in redundancy and long life required for deployment or actuation of devices on spacecraft. Linear-motion motor devices can also be fabricated.
Effects of input device and motion type on a cursor-positioning task.
Yau, Yi-Jan; Hwang, Sheue-Ling; Chao, Chin-Jung
2008-02-01
Many studies have investigated the performance of using nonkey-board input devices under static situations, but few have considered the effects of motion type on manipulating these input devices. In this study comparison of 12 mens' performance using four input devices (three trackballs: currently used, trackman wheel, and erectly held trackballs, as well as a touch screen) under five motion types of static, heave, roll, pitch, and random movements was conducted. The input device and motion type significantly affected movement speed and accuracy, and their interaction significantly affected the movement speed. The touch screen was the fastest but the least accurate input device. The erectly held trackball was the slowest, whereas the error rate of the currently used trackball was the lowest. Impairments of the random motion on movement time and error rate were larger than those of other motion types. Considering objective and subjective evaluations, the trackman wheel and currently used trackball were more efficient in operation than the erectly held trackball and touch screen under the motion environments.
Congruity Effects in Time and Space: Behavioral and ERP Measures
ERIC Educational Resources Information Center
Teuscher, Ursina; McQuire, Marguerite; Collins, Jennifer; Coulson, Seana
2008-01-01
Two experiments investigated whether motion metaphors for time affected the perception of spatial motion. Participants read sentences either about literal motion through space or metaphorical motion through time written from either the ego-moving or object-moving perspective. Each sentence was followed by a cartoon clip. Smiley-moving clips showed…
A New Approach for Human Forearm Motion Assist by Actuated Artificial Joint-An Inner Skeleton Robot
NASA Astrophysics Data System (ADS)
Kundu, Subrata Kumar; Kiguchi, Kazuo; Teramoto, Kenbu
In order to help the physical activities of the elderly or physically disabled persons, we propose a new concept of a power-assist inner skeleton robot (i.e., actuated artificial joint) that is supposed to assist the human daily life motion from inside of the human body. This paper presents an implantable 2 degree of freedom (DOF) inner skeleton robot that is designed to assist human elbow flexion-extension motion and forearm supination-pronation motion for daily life activities. We have developed a prototype of the inner skeleton robot that is supposed to assist the motion from inside of the body and act as an actuated artificial joint. The proposed system is controlled based on the activation patterns of the electromyogram (EMG) signals of the user's muscles by applying fuzzy-neuro control method. A joint actuator with angular position sensor is designed for the inner skeleton robot and a T-Mechanism is proposed to keep the bone arrangement similar to the normal human articulation after the elbow arthroplasty. The effectiveness of the proposed system has been evaluated by experiment.
NASA Astrophysics Data System (ADS)
Hast, Michael; Howe, Christine
2013-07-01
Events involving motion in fall are differentiated psychologically from events involving horizontal motion. Do children associate motion down inclines more with motion along horizontals or more with motion in fall, or do they even treat it as an integration of the two? The question was raised over 20 years ago but never satisfactorily answered, so the principal aim of the reported research was to take matters forward. Children (n = 144) aged 5-11 years were assessed while predicting natural dynamic events along a horizontal, in fall and down an incline. They were required to make predictions of speed with heavy and light balls and under changes in incline heights. The results show that, consistent with previous work, faster horizontal motion was associated with the light ball across all ages, whereas faster fall was associated with the heavy ball. However, while the younger children predicted faster incline motion for the lighter ball, there was a shift in this conception towards older children predicting faster motion for the heavier ball. Understanding of how changes in incline height affect speed was generally good, with this aspect of the study helping to establish how children perceive diagonal dimensions. How supported horizontal motion and unsupported fall motion may affect children's changing understanding of incline motion is discussed, thus providing more complete insight into children's understanding of natural object motion than has been established so far.
Lenssen, Anton F; Crijns, Yvonne H F; Waltjé, Eddie M H; Roox, George M; van Steyn, Mike J A; Geesink, Ruud J T; van den Brandt, Piet A; de Bie, Rob A
2006-02-23
Adequate and intensive rehabilitation is an important requirement for successful Total Knee Arthroplasty. The primary focus of early rehabilitation is ambulation of patients and regaining range of motion in the knee. Although research suggests that Continuous Passive Motion should be implemented in the first rehabilitation phase following surgery, there is substantial debate about the duration of each session and the total period of CPM application and. A Cochrane review on this topic concluded that short-term use of CPM leads to greater short-term range of motion. It also suggested, however, that future research should concentrate on the treatment period during which CPM should be administered. In a randomised controlled trial we intend to investigate the efficacy of prolonged use of a continuous passive motion (CPM) device in the home situation as an adjunct to standardised physical therapy. The experimental treatment is compared to standardised physical therapy, in patients with osteoarthritis of the knee undergoing Total Knee Arthroplasty (TKA). Efficacy will be assessed in terms of faster improvements in range of motion and functional recovery. Seventy patients with knee osteoarthritis undergoing TKA and experiencing early postoperative flexion impairment (less than 80 degrees of knee flexion at the time of discharge) will be randomised over two treatment groups, a usual care group and an experimental group. The experimental group will receive CPM + physiotherapy for 17 consecutive days after surgery, whereas the usual care group will receive the same treatment during the in-hospital phase (i.e. about four days), followed by physical therapy alone (usual care) in the first two weeks after hospital discharge. From 18 days to three months after discharge, both groups will receive standardised PT. The primary focus of rehabilitation will be functional recovery (e.g. ambulation) and regaining range of motion (ROM) in the knee. Because restricted knee ROM affects functional activities, knee ROM and knee function are regarded as the primary indicators of successful TKA. Potential effects of the intervention under study include rapid return of knee flexion accompanied by earlier return to functional activities of daily life. If patients benefit significantly from prolonged CPM use, this treatment should be added to the standard PT treatment at home. We expect the additional home CPM programme to be more effective than the usual physiotherapy programme, resulting in a difference in ROM of at least 5 degrees , 17 days after surgery. This clinically important difference, with a possible flexion ROM of about 100 degrees , is expected to lead to better functioning in activities of daily life, like walking, and earlier ability to cycle. These advantages should result in earlier and increasing independence.
Lenssen, Anton F; Crijns, Yvonne HF; Waltjé, Eddie MH; Roox, George M; van Steyn, Mike JA; Geesink, Ruud JT; van den Brandt, Piet A; de Bie, Rob A
2006-01-01
Background Adequate and intensive rehabilitation is an important requirement for successful Total Knee Arthroplasty. The primary focus of early rehabilitation is ambulation of patients and regaining range of motion in the knee. Although research suggests that Continuous Passive Motion should be implemented in the first rehabilitation phase following surgery, there is substantial debate about the duration of each session and the total period of CPM application and. A Cochrane review on this topic concluded that short-term use of CPM leads to greater short-term range of motion. It also suggested, however, that future research should concentrate on the treatment period during which CPM should be administered. Methods In a randomised controlled trial we intend to investigate the efficacy of prolonged use of a continuous passive motion (CPM) device in the home situation as an adjunct to standardised physical therapy. The experimental treatment is compared to standardised physical therapy, in patients with osteoarthritis of the knee undergoing Total Knee Arthroplasty (TKA). Efficacy will be assessed in terms of faster improvements in range of motion and functional recovery. Seventy patients with knee osteoarthritis undergoing TKA and experiencing early postoperative flexion impairment (less than 80° of knee flexion at the time of discharge) will be randomised over two treatment groups, a usual care group and an experimental group The experimental group will receive CPM + physiotherapy for 17 consecutive days after surgery, whereas the usual care group will receive the same treatment during the in-hospital phase (i.e. about four days), followed by physical therapy alone (usual care) in the first two weeks after hospital discharge. From 18 days to three months after discharge, both groups will receive standardised PT. The primary focus of rehabilitation will be functional recovery (e.g. ambulation) and regaining range of motion (ROM) in the knee. Discussion Because restricted knee ROM affects functional activities, knee ROM and knee function are regarded as the primary indicators of successful TKA. Potential effects of the intervention under study include rapid return of knee flexion accompanied by earlier return to functional activities of daily life. If patients benefit significantly from prolonged CPM use, this treatment should be added to the standard PT treatment at home. We expect the additional home CPM programme to be more effective than the usual physiotherapy programme, resulting in a difference in ROM of at least 5°, 17 days after surgery. This clinically important difference, with a possible flexion ROM of about 100°, is expected to lead to better functioning in activities of daily life, like walking, and earlier ability to cycle. These advantages should result in earlier and increasing independence. PMID:16504087
Carriot, Jerome; Jamali, Mohsen; Brooks, Jessica X.
2015-01-01
Traditionally, the neural encoding of vestibular information is studied by applying either passive rotations or translations in isolation. However, natural vestibular stimuli are typically more complex. During everyday life, our self-motion is generally not restricted to one dimension, but rather comprises both rotational and translational motion that will simultaneously stimulate receptors in the semicircular canals and otoliths. In addition, natural self-motion is the result of self-generated and externally generated movements. However, to date, it remains unknown how information about rotational and translational components of self-motion is integrated by vestibular pathways during active and/or passive motion. Accordingly, here, we compared the responses of neurons at the first central stage of vestibular processing to rotation, translation, and combined motion. Recordings were made in alert macaques from neurons in the vestibular nuclei involved in postural control and self-motion perception. In response to passive stimulation, neurons did not combine canal and otolith afferent information linearly. Instead, inputs were subadditively integrated with a weighting that was frequency dependent. Although canal inputs were more heavily weighted at low frequencies, the weighting of otolith input increased with frequency. In response to active stimulation, neuronal modulation was significantly attenuated (∼70%) relative to passive stimulation for rotations and translations and even more profoundly attenuated for combined motion due to subadditive input integration. Together, these findings provide insights into neural computations underlying the integration of semicircular canal and otolith inputs required for accurate posture and motor control, as well as perceptual stability, during everyday life. PMID:25716854
Tuning self-motion perception in virtual reality with visual illusions.
Bruder, Gerd; Steinicke, Frank; Wieland, Phil; Lappe, Markus
2012-07-01
Motion perception in immersive virtual environments significantly differs from the real world. For example, previous work has shown that users tend to underestimate travel distances in virtual environments (VEs). As a solution to this problem, researchers proposed to scale the mapped virtual camera motion relative to the tracked real-world movement of a user until real and virtual motion are perceived as equal, i.e., real-world movements could be mapped with a larger gain to the VE in order to compensate for the underestimation. However, introducing discrepancies between real and virtual motion can become a problem, in particular, due to misalignments of both worlds and distorted space cognition. In this paper, we describe a different approach that introduces apparent self-motion illusions by manipulating optic flow fields during movements in VEs. These manipulations can affect self-motion perception in VEs, but omit a quantitative discrepancy between real and virtual motions. In particular, we consider to which regions of the virtual view these apparent self-motion illusions can be applied, i.e., the ground plane or peripheral vision. Therefore, we introduce four illusions and show in experiments that optic flow manipulation can significantly affect users' self-motion judgments. Furthermore, we show that with such manipulations of optic flow fields the underestimation of travel distances can be compensated.
A New Way that Planets can Affect the Sun
NASA Technical Reports Server (NTRS)
Wolff, Charles; Patrone, Paul
2010-01-01
As planets orbit the Sun, the Sun also has to move to keep the total momentum of the solar system constant. The Sun's small orbital motion plus its 25 day rotation about its axis combine to invigorate some solar instabilities. Occasional convection cells at the proper phase in their short life can be strengthened by factors of two or more. This local burst of extra kinetic energy eventually reaches the surface where it can increase the intensity of solar activity. It might explain some reports in the last century of how planetary positions correlate with solar activity. This is the first effect of planets that is large enough to cause a significant response on the Sun.
Paradoxical physiological transitions from aging to late life in Drosophila.
Shahrestani, Parvin; Quach, Julie; Mueller, Laurence D; Rose, Michael R
2012-02-01
In a variety of organisms, adulthood is divided into aging and late life, where aging is a period of exponentially increasing mortality rates and late life is a period of roughly plateaued mortality rates. In this study we used ∼57,600 Drosophila melanogaster from six replicate populations to examine the physiological transitions from aging to late life in four functional characters that decline during aging: desiccation resistance, starvation resistance, time spent in motion, and negative geotaxis. Time spent in motion and desiccation resistance declined less quickly in late life compared to their patterns of decline during aging. Negative geotaxis declined at a faster rate in late life compared to its rate of decline during aging. These results yield two key findings: (1) Late-life physiology is distinct from the physiology of aging, in that there is not simply a continuation of the physiological trends which characterize aging; and (2) late life physiology is complex, in that physiological characters vary with respect to their stabilization, deceleration, or acceleration in the transition from aging to late life. These findings imply that a correct understanding of adulthood requires identifying and appropriately characterizing physiology during properly delimited late-life periods as well as aging periods.
Paradoxical Physiological Transitions from Aging to Late Life in Drosophila
Quach, Julie; Mueller, Laurence D.; Rose, Michael R.
2012-01-01
Abstract In a variety of organisms, adulthood is divided into aging and late life, where aging is a period of exponentially increasing mortality rates and late life is a period of roughly plateaued mortality rates. In this study we used ∼57,600 Drosophila melanogaster from six replicate populations to examine the physiological transitions from aging to late life in four functional characters that decline during aging: desiccation resistance, starvation resistance, time spent in motion, and negative geotaxis. Time spent in motion and desiccation resistance declined less quickly in late life compared to their patterns of decline during aging. Negative geotaxis declined at a faster rate in late life compared to its rate of decline during aging. These results yield two key findings: (1) Late-life physiology is distinct from the physiology of aging, in that there is not simply a continuation of the physiological trends which characterize aging; and (2) late life physiology is complex, in that physiological characters vary with respect to their stabilization, deceleration, or acceleration in the transition from aging to late life. These findings imply that a correct understanding of adulthood requires identifying and appropriately characterizing physiology during properly delimited late-life periods as well as aging periods. PMID:22233126
DOT National Transportation Integrated Search
2014-01-01
A comprehensive field detection method is proposed that is aimed at developing advanced capability for : reliable monitoring, inspection and life estimation of bridge infrastructure. The goal is to utilize Motion-Sensing Radio Transponders (RFIDS) on...
Lebel, Karina; Boissy, Patrick; Hamel, Mathieu; Duval, Christian
2013-01-01
Background Inertial measurement of motion with Attitude and Heading Reference Systems (AHRS) is emerging as an alternative to 3D motion capture systems in biomechanics. The objectives of this study are: 1) to describe the absolute and relative accuracy of multiple units of commercially available AHRS under various types of motion; and 2) to evaluate the effect of motion velocity on the accuracy of these measurements. Methods The criterion validity of accuracy was established under controlled conditions using an instrumented Gimbal table. AHRS modules were carefully attached to the center plate of the Gimbal table and put through experimental static and dynamic conditions. Static and absolute accuracy was assessed by comparing the AHRS orientation measurement to those obtained using an optical gold standard. Relative accuracy was assessed by measuring the variation in relative orientation between modules during trials. Findings Evaluated AHRS systems demonstrated good absolute static accuracy (mean error < 0.5o) and clinically acceptable absolute accuracy under condition of slow motions (mean error between 0.5o and 3.1o). In slow motions, relative accuracy varied from 2o to 7o depending on the type of AHRS and the type of rotation. Absolute and relative accuracy were significantly affected (p<0.05) by velocity during sustained motions. The extent of that effect varied across AHRS. Interpretation Absolute and relative accuracy of AHRS are affected by environmental magnetic perturbations and conditions of motions. Relative accuracy of AHRS is mostly affected by the ability of all modules to locate the same global reference coordinate system at all time. Conclusions Existing AHRS systems can be considered for use in clinical biomechanics under constrained conditions of use. While their individual capacity to track absolute motion is relatively consistent, the use of multiple AHRS modules to compute relative motion between rigid bodies needs to be optimized according to the conditions of operation. PMID:24260324
Motion perception without Nystagmus--a novel manifestation of cerebellar stroke.
Shaikh, Aasef G
2014-01-01
The motion perception and the vestibulo-ocular reflex (VOR) each serve distinct functions. The VOR keeps the gaze steady on the target of interest, whereas vestibular perception serves a number of tasks, including awareness of self-motion and orientation in space. VOR and motion perception might abide the same neurophysiological principles, but their distinct anatomical correlates were proposed. In patients with cerebellar stroke in distribution of medial division of posterior inferior cerebellar artery, we asked whether specific location of the focal lesion in vestibulocerebellum could cause impaired perception of motion but normal eye movements. Thirteen patients were studied, 5 consistently perceived spinning of surrounding environment (vertigo), but the eye movements were normal. This group was called "disease model." Remaining 8 patients were also symptomatic for vertigo, but they had spontaneous nystagmus. The latter group was called "disease control." Magnetic resonance imaging in both groups consistently revealed focal cerebellar infarct affecting posterior cerebellar vermis (lobule IX). In the "disease model" group, only part of lobule IX was affected. In the disease control group, however, complete lobule IX was involved. This study discovered a novel presentation of cerebellar stroke where only motion perception was affected, but there was an absence of objective neurologic signs. Copyright © 2014 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Lattice Boltzmann for Simulation of Gases Mixture in Fruit Storage Chambers
NASA Astrophysics Data System (ADS)
Fabero, J. C.; Barreiro, P.; Casasús, L.
2003-04-01
Fluid Dynamics can be modelled through the Navier-Stokes equations. This description corresponds to a macroscopic definition of the fluid motion phenomena. During the past 20 year new simulation procedures are emerging from Statistical Physics and Computer Science domains. One of them is the Lattice Gas Cellular Automata (LGCA) method. This approach, which is considered to be a microscopic description of the world, in spite of its intuitiveness and numerical efficiency, fails to simulate the real Navier-Stokes equations. Another classical simulation procedure for the fluid motion phenomena is the so called Lattice Boltzmann method [1]. This corresponds to a meso-scale description of the world [2]. Simulation of laminar and turbulent motions of fluids, specially when considering several gas species is still an ongoing research [3]. Nowadays, the use of Low Oxygen and Ultra Low Oxygen Controlled Atmospheres has been recognized as a reliable method to extend the storage life of fruits an vegetables. However, small spatial gradients in gas concentration during storage may generate internal disorders in the commodities. In this work, four different gases will be considered: oxygen, carbon dioxide, water vapor and ethylene. Physiological effects such as transpiration, which affects the level of water vapor, respiration, which modifies both oxygen and carbon dioxide concentrations, and ethylene emission, must be taken into account in the hole model. The numerical model, based on that proposed by Shan and Chen, is implemented, being able to consider the behavior of multiple mixable gas species. Forced air motion, needed to obtain a correct ventilation of the chamber, has also been modelled.
Seno, Takeharu; Fukuda, Haruaki
2012-01-01
Over the last 100 years, numerous studies have examined the effective visual stimulus properties for inducing illusory self-motion (known as vection). This vection is often experienced more strongly in daily life than under controlled experimental conditions. One well-known example of vection in real life is the so-called 'train illusion'. In the present study, we showed that this train illusion can also be generated in the laboratory using virtual computer graphics-based motion stimuli. We also demonstrated that this vection can be modified by altering the meaning of the visual stimuli (i.e., top down effects). Importantly, we show that the semantic meaning of a stimulus can inhibit or facilitate vection, even when there is no physical change to the stimulus.
Ball motion and sliding friction in an arched outer-race ball bearing
NASA Technical Reports Server (NTRS)
Hamrock, B. J.
1974-01-01
The motion of the ball and sliding friction in an arched outer-race ball bearing under thrust load is analyzed. Fatigue life evaluations were made. The analysis is applied to a 150-millimeter-bore ball bearing. The results indicated that for high-speed light-load applications the arched bearing has significant improvement in fatigue life over that of a conventional bearing. An arching of 0.254 mm (0.01 in.) was found to be optimal. Also, for an arched bearing a considerable amount of spinning occurs at the outer-race contacts.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 12 Banks and Banking 6 2011-01-01 2011-01-01 false Motions. 747.23 Section 747.23 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING CREDIT UNIONS ADMINISTRATIVE ACTIONS... Procedure § 747.23 Motions. (a) In writing. (1) Except as otherwise provided herein, an application or...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Motions. 747.23 Section 747.23 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING CREDIT UNIONS ADMINISTRATIVE ACTIONS... Procedure § 747.23 Motions. (a) In writing. (1) Except as otherwise provided herein, an application or...
“What Women Like”: Influence of Motion and Form on Esthetic Body Perception
Cazzato, Valentina; Siega, Serena; Urgesi, Cosimo
2012-01-01
Several studies have shown the distinct contribution of motion and form to the esthetic evaluation of female bodies. Here, we investigated how variations of implied motion and body size interact in the esthetic evaluation of female and male bodies in a sample of young healthy women. Participants provided attractiveness, beauty, and liking ratings for the shape and posture of virtual renderings of human bodies with variable body size and implied motion. The esthetic judgments for both shape and posture of human models were influenced by body size and implied motion, with a preference for thinner and more dynamic stimuli. Implied motion, however, attenuated the impact of extreme body size on the esthetic evaluation of body postures, while body size variations did not affect the preference for more dynamic stimuli. Results show that body form and action cues interact in esthetic perception, but the final esthetic appreciation of human bodies is predicted by a mixture of perceptual and affective evaluative components. PMID:22866044
NASA Astrophysics Data System (ADS)
Marumo, Yoshitaka; Katayama, Tsuyoshi
This study uses the energy flow method to analyze how structural flexibility affects the motorcycle wobble and weave modes. Lateral bending of the front fork and torsion of the main frame affect the wobble mode stability. These are based on the gyroscopic effect of the front wheel in the steering motion by considering structural flexibility. At high speeds, lateral bending of the front fork and torsion of the rear swing arm more significantly affect the weave mode stability. These are primarily due to the phase changes of the external force generated by the yaw rate in the lateral motion. The phase change of the yaw rate force in the lateral motion originates from the phase change of the tire side forces.
8 CFR 245a.12 - Filing and applications.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 4, 2003. To benefit from the provisions of LIFE Legalization, an alien must properly file an... or motion to reconsider. An alien who is prima facie eligible for adjustment of status under LIFE... unrelated to this Subpart B, the alien may apply before the Service for LIFE Legalization adjustment of...
8 CFR 245a.12 - Filing and applications.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 4, 2003. To benefit from the provisions of LIFE Legalization, an alien must properly file an... or motion to reconsider. An alien who is prima facie eligible for adjustment of status under LIFE... unrelated to this Subpart B, the alien may apply before the Service for LIFE Legalization adjustment of...
8 CFR 245a.12 - Filing and applications.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 4, 2003. To benefit from the provisions of LIFE Legalization, an alien must properly file an... or motion to reconsider. An alien who is prima facie eligible for adjustment of status under LIFE... unrelated to this Subpart B, the alien may apply before the Service for LIFE Legalization adjustment of...
Reading Emotion From Mouse Cursor Motions: Affective Computing Approach.
Yamauchi, Takashi; Xiao, Kunchen
2018-04-01
Affective computing research has advanced emotion recognition systems using facial expressions, voices, gaits, and physiological signals, yet these methods are often impractical. This study integrates mouse cursor motion analysis into affective computing and investigates the idea that movements of the computer cursor can provide information about emotion of the computer user. We extracted 16-26 trajectory features during a choice-reaching task and examined the link between emotion and cursor motions. Participants were induced for positive or negative emotions by music, film clips, or emotional pictures, and they indicated their emotions with questionnaires. Our 10-fold cross-validation analysis shows that statistical models formed from "known" participants (training data) could predict nearly 10%-20% of the variance of positive affect and attentiveness ratings of "unknown" participants, suggesting that cursor movement patterns such as the area under curve and direction change help infer emotions of computer users. Copyright © 2017 Cognitive Science Society, Inc.
Jiang, Fang; Stecker, G. Christopher; Boynton, Geoffrey M.; Fine, Ione
2016-01-01
Early blind subjects exhibit superior abilities for processing auditory motion, which are accompanied by enhanced BOLD responses to auditory motion within hMT+ and reduced responses within right planum temporale (rPT). Here, by comparing BOLD responses to auditory motion in hMT+ and rPT within sighted controls, early blind, late blind, and sight-recovery individuals, we were able to separately examine the effects of developmental and adult visual deprivation on cortical plasticity within these two areas. We find that both the enhanced auditory motion responses in hMT+ and the reduced functionality in rPT are driven by the absence of visual experience early in life; neither loss nor recovery of vision later in life had a discernable influence on plasticity within these areas. Cortical plasticity as a result of blindness has generally be presumed to be mediated by competition across modalities within a given cortical region. The reduced functionality within rPT as a result of early visual loss implicates an additional mechanism for cross modal plasticity as a result of early blindness—competition across different cortical areas for functional role. PMID:27458357
Nonlinear circuits for naturalistic visual motion estimation
Fitzgerald, James E; Clark, Damon A
2015-01-01
Many animals use visual signals to estimate motion. Canonical models suppose that animals estimate motion by cross-correlating pairs of spatiotemporally separated visual signals, but recent experiments indicate that humans and flies perceive motion from higher-order correlations that signify motion in natural environments. Here we show how biologically plausible processing motifs in neural circuits could be tuned to extract this information. We emphasize how known aspects of Drosophila's visual circuitry could embody this tuning and predict fly behavior. We find that segregating motion signals into ON/OFF channels can enhance estimation accuracy by accounting for natural light/dark asymmetries. Furthermore, a diversity of inputs to motion detecting neurons can provide access to more complex higher-order correlations. Collectively, these results illustrate how non-canonical computations improve motion estimation with naturalistic inputs. This argues that the complexity of the fly's motion computations, implemented in its elaborate circuits, represents a valuable feature of its visual motion estimator. DOI: http://dx.doi.org/10.7554/eLife.09123.001 PMID:26499494
[Change of host's behavior including man under the influence of parasites].
Sergiev, V P
2010-01-01
Directed modulation of hosts' behavior favouring transmission of pathogen was noted in many parasites and, above all, in helminthes, which life cycle includes the consequent change of several hosts. It turned out that parasites use the same neuromediators for change of behavior of both mammals and hosts belonging to other animal classes. In fishes as well as in mammals, monoamines-neurotransmitters assist in brain functioning. Norepinephrine, dopamine and serotonin affect the alimentation, motion activity, aggression and social behaviour. Changes in concentration ratio of serotonin and its metabolites in invaded species were more pronounced, which pointed to directed effects of pathogens on serotonin activity. The same effect of some pathogens on human behaviour does not have selective significance because humans are not an essential link in life cycle of many parasites. Although the mentioned effect on behaviour could lead to negative consequences. For examples, persons with latent toxoplasmosis are significantly more frequent become members or victims of traffic accidents due to decreased ability for concentration of attention.
Assessment and rehabilitation of chronic low back pain in baseball: part II
Wasser, Joseph G.; Zaremski, Jason L.; Herman, Daniel C.; Vincent, Heather K.
2017-01-01
Repetitive throwing and hitting motions in baseball place mechanical stresses to the lumbar spine which may cause low back pain (LBP). Pain may be due to vertebral stress reactions or insufficiency fractures, intervertebral disc degeneration or intervertebral disc herniation. Untreated chronic conditions have high potential to lead to a more significant injury such as spondylolysis. Chronic LBP increases the risk for missed playing time, early career termination and lower quality of life after retirement. Proper clinical assessment and prevention/rehabilitation of LBP in this population is thus important for performance, play time and overall long-term quality of life. This narrative review synopsizes the available evidence for assessment and rehabilitation of baseball players with LBP, including the structured rehabilitative techniques and programmes which should be administered to affected players. The state of the evidence suggests that there are deficits in identifying the optimal prevention and rehabilitation prescription components for the variety of LBP-inducing injuries in this athletic population. PMID:28128000
Assessment and rehabilitation of chronic low back pain in baseball: part II.
Wasser, Joseph G; Zaremski, Jason L; Herman, Daniel C; Vincent, Heather K
2017-01-01
Repetitive throwing and hitting motions in baseball place mechanical stresses to the lumbar spine which may cause low back pain (LBP). Pain may be due to vertebral stress reactions or insufficiency fractures, intervertebral disc degeneration or intervertebral disc herniation. Untreated chronic conditions have high potential to lead to a more significant injury such as spondylolysis. Chronic LBP increases the risk for missed playing time, early career termination and lower quality of life after retirement. Proper clinical assessment and prevention/rehabilitation of LBP in this population is thus important for performance, play time and overall long-term quality of life. This narrative review synopsizes the available evidence for assessment and rehabilitation of baseball players with LBP, including the structured rehabilitative techniques and programmes which should be administered to affected players. The state of the evidence suggests that there are deficits in identifying the optimal prevention and rehabilitation prescription components for the variety of LBP-inducing injuries in this athletic population.
End-of-life disposal of high elliptical orbit missions: The case of INTEGRAL
NASA Astrophysics Data System (ADS)
Armellin, Roberto; San-Juan, Juan F.; Lara, Martin
2015-08-01
Nowadays there is international consensus that space activities must be managed to minimize debris generation and risk. The paper presents a method for the end-of-life (EoL) disposal of spacecraft in high elliptical orbits (HEO). The time evolution of HEO is strongly affected by Earth's oblateness and luni-solar perturbation, and this can cause in the long-term to extended interferences with low Earth orbit (LEO) protected region and uncontrolled Earth re-entry. An EoL disposal concept that exploits the effect of orbital perturbations to reduce the disposal cost is presented. The problem is formulated as a multiobjective optimization problem, which is solved with an evolutionary algorithm. To explore at the best the search space a semi-analytical orbit propagator, which allows the propagation of the orbit motion for 100 years in few seconds, is adopted. The EoL disposal of the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL) mission is used as a practical test-case to show the effectiveness of the proposed methodology.
Reconfigurable paramagnetic microswimmers: Brownian motion affects non-reciprocal actuation.
Du, Di; Hilou, Elaa; Biswal, Sibani Lisa
2018-05-09
Swimming at low Reynolds number is typically dominated by a large viscous drag, therefore microscale swimmers require non-reciprocal body deformation to generate locomotion. Purcell described a simple mechanical swimmer at the microscale consisting of three rigid components connected together with two hinges. Here we present a simple microswimmer consisting of two rigid paramagnetic particles with different sizes. When placed in an eccentric magnetic field, this simple microswimmer exhibits non-reciprocal body motion and its swimming locomotion can be directed in a controllable manner. Additional components can be added to create a multibody microswimmer, whereby the particles act cooperatively and translate in a given direction. For some multibody swimmers, the stochastic thermal forces fragment the arm, which therefore modifies the swimming strokes and changes the locomotive speed. This work offers insight into directing the motion of active systems with novel time-varying magnetic fields. It also reveals that Brownian motion not only affects the locomotion of reciprocal swimmers that are subject to the Scallop theorem, but also affects that of non-reciprocal swimmers.
Correction for human head motion in helical x-ray CT
NASA Astrophysics Data System (ADS)
Kim, J.-H.; Sun, T.; Alcheikh, A. R.; Kuncic, Z.; Nuyts, J.; Fulton, R.
2016-02-01
Correction for rigid object motion in helical CT can be achieved by reconstructing from a modified source-detector orbit, determined by the object motion during the scan. This ensures that all projections are consistent, but it does not guarantee that the projections are complete in the sense of being sufficient for exact reconstruction. We have previously shown with phantom measurements that motion-corrected helical CT scans can suffer from data-insufficiency, in particular for severe motions and at high pitch. To study whether such data-insufficiency artefacts could also affect the motion-corrected CT images of patients undergoing head CT scans, we used an optical motion tracking system to record the head movements of 10 healthy volunteers while they executed each of the 4 different types of motion (‘no’, slight, moderate and severe) for 60 s. From these data we simulated 354 motion-affected CT scans of a voxelized human head phantom and reconstructed them with and without motion correction. For each simulation, motion-corrected (MC) images were compared with the motion-free reference, by visual inspection and with quantitative similarity metrics. Motion correction improved similarity metrics in all simulations. Of the 270 simulations performed with moderate or less motion, only 2 resulted in visible residual artefacts in the MC images. The maximum range of motion in these simulations would encompass that encountered in the vast majority of clinical scans. With severe motion, residual artefacts were observed in about 60% of the simulations. We also evaluated a new method of mapping local data sufficiency based on the degree to which Tuy’s condition is locally satisfied, and observed that areas with high Tuy values corresponded to the locations of residual artefacts in the MC images. We conclude that our method can provide accurate and artefact-free MC images with most types of head motion likely to be encountered in CT imaging, provided that the motion can be accurately determined.
8 CFR 245a.20 - Decisions, appeals, motions, and certifications.
Code of Federal Regulations, 2014 CFR
2014-01-01
... aliens previously in proceedings—(1) Upon the granting of an application. If the application for LIFE... 8 Aliens and Nationality 1 2014-01-01 2014-01-01 false Decisions, appeals, motions, and certifications. 245a.20 Section 245a.20 Aliens and Nationality DEPARTMENT OF HOMELAND SECURITY IMMIGRATION...
8 CFR 245a.20 - Decisions, appeals, motions, and certifications.
Code of Federal Regulations, 2012 CFR
2012-01-01
... aliens previously in proceedings—(1) Upon the granting of an application. If the application for LIFE... 8 Aliens and Nationality 1 2012-01-01 2012-01-01 false Decisions, appeals, motions, and certifications. 245a.20 Section 245a.20 Aliens and Nationality DEPARTMENT OF HOMELAND SECURITY IMMIGRATION...
8 CFR 245a.20 - Decisions, appeals, motions, and certifications.
Code of Federal Regulations, 2010 CFR
2010-01-01
... aliens previously in proceedings—(1) Upon the granting of an application. If the application for LIFE... 8 Aliens and Nationality 1 2010-01-01 2010-01-01 false Decisions, appeals, motions, and certifications. 245a.20 Section 245a.20 Aliens and Nationality DEPARTMENT OF HOMELAND SECURITY IMMIGRATION...
8 CFR 245a.20 - Decisions, appeals, motions, and certifications.
Code of Federal Regulations, 2013 CFR
2013-01-01
... aliens previously in proceedings—(1) Upon the granting of an application. If the application for LIFE... 8 Aliens and Nationality 1 2013-01-01 2013-01-01 false Decisions, appeals, motions, and certifications. 245a.20 Section 245a.20 Aliens and Nationality DEPARTMENT OF HOMELAND SECURITY IMMIGRATION...
8 CFR 245a.20 - Decisions, appeals, motions, and certifications.
Code of Federal Regulations, 2011 CFR
2011-01-01
... aliens previously in proceedings—(1) Upon the granting of an application. If the application for LIFE... 8 Aliens and Nationality 1 2011-01-01 2011-01-01 false Decisions, appeals, motions, and certifications. 245a.20 Section 245a.20 Aliens and Nationality DEPARTMENT OF HOMELAND SECURITY IMMIGRATION...
Advancing Adventure Education Using Digital Motion-Sensing Games
ERIC Educational Resources Information Center
Shih, Ju-Ling; Hsu, Yu-Jen
2016-01-01
This study used the Xbox Kinect and Unity 3D game engine to develop two motion-sensing games in which the participants, in simulated scenarios, could experience activities that are unattainable in real life, become immersed in collaborative activities, and explore the value of adventure education. Adventure Education involves courses that…
Demonstrating the Direction of Angular Velocity in Circular Motion
ERIC Educational Resources Information Center
Demircioglu, Salih; Yurumezoglu, Kemal; Isik, Hakan
2015-01-01
Rotational motion is ubiquitous in nature, from astronomical systems to household devices in everyday life to elementary models of atoms. Unlike the tangential velocity vector that represents the instantaneous linear velocity (magnitude and direction), an angular velocity vector is conceptually more challenging for students to grasp. In physics…
Motion characteristics of the lumbar spine in the normal population.
McGregor, A H; McCarthy, I D; Hughes, S P
1995-11-15
The present study investigated the dynamic motion characteristics of the lumbar spine in the normal population using a potentiometric analysis system. To assess the ability of a triaxial potentiometric analysis system to measure dynamic motion in the lumbar spine, and to use this system to form a database of dynamic motion characteristics from which normal parameters of motion and the factors affecting this motion could be defined. Spinal motion has been studied using a variety of different methods, the majority of which have been limited either in terms of reliability, accuracy, or invasiveness and many have been only of a static nature. There has been no previous study into the normal dynamic motion characteristics of the lumbar spine. The accuracy of the system was determined by a series of tests against a calibrated engineering mill, and the reliability of the system was assessed on 10 subjects with repeated measurements over a 3-day period. Values of range of motion and angular velocity were obtained from 203 normal subjects during flexion and extension, lateral flexion, and rotation. The results of the calibration testing revealed excellent accuracy, and it was shown that the system was repeatable. Initial analysis of the results indicated that sex differences did exist with men having 58.4 degrees of flexion and women having 53.4 degrees. Age appeared to have an influence on motion, and a gradual reduction was seen with each decade (P < 0.001), with the 20-29-year age range having 59.5 degrees mean flexion, the 30-39-year group having 58.1 degrees, the 40-49-year group having 53.7 degrees, the 50-60-year group having 57.5 degrees, and the 60-70-year group having 45.9 degrees. Multiple regression techniques revealed that only a few factors are important with respect to motion and that these varied according to the characteristic being defined. Range of motion tended to be affected by age and sex, whereas velocity was only affected by distance moved, with occupation and body mass index having little or no influence on the motion. The factors identified could only account for a small proportion of the variation seen, suggesting that it is difficult to predict the motion characteristics with any degree of sensitivity.
Brownian motion with adaptive drift for remaining useful life prediction: Revisited
NASA Astrophysics Data System (ADS)
Wang, Dong; Tsui, Kwok-Leung
2018-01-01
Linear Brownian motion with constant drift is widely used in remaining useful life predictions because its first hitting time follows the inverse Gaussian distribution. State space modelling of linear Brownian motion was proposed to make the drift coefficient adaptive and incorporate on-line measurements into the first hitting time distribution. Here, the drift coefficient followed the Gaussian distribution, and it was iteratively estimated by using Kalman filtering once a new measurement was available. Then, to model nonlinear degradation, linear Brownian motion with adaptive drift was extended to nonlinear Brownian motion with adaptive drift. However, in previous studies, an underlying assumption used in the state space modelling was that in the update phase of Kalman filtering, the predicted drift coefficient at the current time exactly equalled the posterior drift coefficient estimated at the previous time, which caused a contradiction with the predicted drift coefficient evolution driven by an additive Gaussian process noise. In this paper, to alleviate such an underlying assumption, a new state space model is constructed. As a result, in the update phase of Kalman filtering, the predicted drift coefficient at the current time evolves from the posterior drift coefficient at the previous time. Moreover, the optimal Kalman filtering gain for iteratively estimating the posterior drift coefficient at any time is mathematically derived. A discussion that theoretically explains the main reasons why the constructed state space model can result in high remaining useful life prediction accuracies is provided. Finally, the proposed state space model and its associated Kalman filtering gain are applied to battery prognostics.
Effect of Space Vehicle Structure Vibration on Control Moment Gyroscope Dynamics
NASA Technical Reports Server (NTRS)
Dobrinskaya, Tatiana
2008-01-01
Control Moment Gyroscopes (CMGs) are used for non-propulsive attitude control of satellites and space stations, including the International Space Station (ISS). CMGs could be essential for future long duration space missions due to the fact that they help to save propellant. CMGs were successfully tested on the ground for many years, and have been successfully used on satellites. However, operations have shown that the CMG service life on the ISS is significantly shorter than predicted. Since the dynamic environment of the ISS differs greatly from the nominal environment of satellites, it was important to analyze how operations specific to the station (dockings and undockings, huge solar array motion, crew exercising, robotic operations, etc) can affect the CMG performance. This task became even more important since the first CMG failure onboard the ISS. The CMG failure resulted in the limitation of the attitude control capabilities, more propellant consumption, and additional operational issues. Therefore, the goal of this work was to find out how the vibrations of a space vehicle structure, caused by a variety of onboard operations, can affect the CMG dynamics and performance. The equations of CMG motion were derived and analyzed for the case when the gyro foundation can vibrate in any direction. The analysis was performed for unbalanced CMG gimbals to match the CMG configuration on ISS. The analysis showed that vehicle structure vibrations can amplify and significantly change the CMG motion if the gyro gimbals are unbalanced in flight. The resonance frequencies were found. It was shown that the resonance effect depends on the magnitude of gimbal imbalance, on the direction of a structure vibration, and on gimbal bearing friction. Computer modeling results of CMG dynamics affected by the external vibration are presented. The results can explain some of the CMG vibration telemetry observed on ISS. This work shows that balancing the CMG gimbals decreases the effect of vehicle structure vibration on CMGs. Additionally, the effect of external vibrations may also be decreased by increasing the gimbal bearing friction. With the suggested modifications there may be no need to lower the gimbal rates below the nominal design requirements as it is currently done on ISS. The conclusions of this work
The effects of cyclical axial motion on rotary endodontic instrument fatigue.
Dederich, D N; Zakariasen, K L
1986-02-01
A potential problem with the use of rotary engine-driven files to flare canals is metal fatigue and subsequent breakage. This study analyzes the effects of cyclical axial motion on instrument failure by fatigue testing of endodontic files with and without cyclical axial motion. Eighteen new instruments, sizes 15 to 45, were mounted in a lathe and turned at 1650 rpm in the lubricated lumen of a curved Pyrex capillary tube until failure occurred. Nine instruments of each size were turned with cyclical axial motion and nine were turned without it. The results indicated that cyclical axial motion can significantly extend the life span of rotary engine files. Torsional forces were not considered in this study.
Synchrony in Joint Action Is Directed by Each Participant’s Motor Control System
Noy, Lior; Weiser, Netta; Friedman, Jason
2017-01-01
In this work, we ask how the probability of achieving synchrony in joint action is affected by the choice of motion parameters of each individual. We use the mirror game paradigm to study how changes in leader’s motion parameters, specifically frequency and peak velocity, affect the probability of entering the state of co-confidence (CC) motion: a dyadic state of synchronized, smooth and co-predictive motions. In order to systematically study this question, we used a one-person version of the mirror game, where the participant mirrored piece-wise rhythmic movements produced by a computer on a graphics tablet. We systematically varied the frequency and peak velocity of the movements to determine how these parameters affect the likelihood of synchronized joint action. To assess synchrony in the mirror game we used the previously developed marker of co-confident (CC) motions: smooth, jitter-less and synchronized motions indicative of co-predicative control. We found that when mirroring movements with low frequencies (i.e., long duration movements), the participants never showed CC, and as the frequency of the stimuli increased, the probability of observing CC also increased. This finding is discussed in the framework of motor control studies showing an upper limit on the duration of smooth motion. We confirmed the relationship between motion parameters and the probability to perform CC with three sets of data of open-ended two-player mirror games. These findings demonstrate that when performing movements together, there are optimal movement frequencies to use in order to maximize the possibility of entering a state of synchronized joint action. It also shows that the ability to perform synchronized joint action is constrained by the properties of our motor control systems. PMID:28443047
How a life-like system emerges from a simplistic particle motion law.
Schmickl, Thomas; Stefanec, Martin; Crailsheim, Karl
2016-11-30
Self-structuring patterns can be observed all over the universe, from galaxies to molecules to living matter, yet their emergence is waiting for full understanding. We discovered a simple motion law for moving and interacting self-propelled particles leading to a self-structuring, self-reproducing and self-sustaining life-like system. The patterns emerging within this system resemble patterns found in living organisms. The emergent cells we found show a distinct life cycle and even create their own ecosystem from scratch. These structures grow and reproduce on their own, show self-driven behavior and interact with each other. Here we analyze the macroscopic properties of the emerging ecology, as well as the microscopic properties of the mechanism that leads to it. Basic properties of the emerging structures (size distributions, longevity) are analyzed as well as their resilience against sensor or actuation noise. Finally, we explore parameter space for potential other candidates of life. The generality and simplicity of the motion law provokes the thought that one fundamental rule, described by one simple equation yields various structures in nature: it may work on different time- and size scales, ranging from the self-structuring universe, to emergence of living beings, down to the emergent subatomic formation of matter.
How a life-like system emerges from a simple particle motion law
Schmickl, Thomas; Stefanec, Martin; Crailsheim, Karl
2016-01-01
Self-structuring patterns can be observed all over the universe, from galaxies to molecules to living matter, yet their emergence is waiting for full understanding. We discovered a simple motion law for moving and interacting self-propelled particles leading to a self-structuring, self-reproducing and self-sustaining life-like system. The patterns emerging within this system resemble patterns found in living organisms. The emergent cells we found show a distinct life cycle and even create their own ecosystem from scratch. These structures grow and reproduce on their own, show self-driven behavior and interact with each other. Here we analyze the macroscopic properties of the emerging ecology, as well as the microscopic properties of the mechanism that leads to it. Basic properties of the emerging structures (size distributions, longevity) are analyzed as well as their resilience against sensor or actuation noise. Finally, we explore parameter space for potential other candidates of life. The generality and simplicity of the motion law provokes the thought that one fundamental rule, described by one simple equation yields various structures in nature: it may work on different time- and size scales, ranging from the self-structuring universe, to emergence of living beings, down to the emergent subatomic formation of matter. PMID:27901107
Apparent diffusion coefficient measurement in a moving phantom simulating linear respiratory motion.
Kwee, Thomas C; Takahara, Taro; Muro, Isao; Van Cauteren, Marc; Imai, Yutaka; Nievelstein, Rutger A J; Mali, Willem P T M; Luijten, Peter R
2010-10-01
The aim of this study was to examine the effect of simulated linear respiratory motion on apparent diffusion coefficient (ADC) measurements. Six rectangular test tubes (14 × 92 mm) filled with either water, tomato ketchup, or mayonnaise were positioned in a box containing agarose gel. This box was connected to a double-acting pneumatic cylinder, capable of inducing periodic linear motion in the long-axis direction of the magnetic bore (23-mm stroke). Diffusion-weighted magnetic resonance imaging was performed for both the static and moving phantoms, and ADC measurements were made in the six test tubes in both situations. In the three test tubes whose long axes were parallel to the direction of motion, ADCs agreed well between the moving and static phantom situations. However, in two test tubes that were filled with fluids that had a considerably lower diffusion coefficient than the surrounding agarose gel, and whose long axes were perpendicular to the direction of motion, the ADCs agreed poorly between the moving and static phantom situations. ADC measurements of large homogeneous structures are not affected by linear respiratory motion. However, ADC measurements of inhomogeneous or small structures are affected by linear respiratory motion due to partial volume effects.
Fikentscher, T; Springorum, H R; Grifka, J; Götz, J
2017-04-01
Due to the frequent presence of comorbidities in patients suffering from rheumatism with increased perioperative risk factors, conservative treatment is often needed. Besides pharmacological treatment, physiotherapy and occupational therapy, a variety of orthoses are available depending on the individual indications. They can be used to stabilize or support joints, limit the range of motion, prevent unphysiological movements or provide relief for affected limbs. In order to choose the right kind of orthosis, the physician should know the underlying cause of disease. Furthermore, for patients with rheumatism many devices are available for daily living that use ergonomic handles or improved leverage effects to compensate for the often severe limitations and to improve the quality of life.
Ball motion and sliding friction in an arched outer race ball bearing
NASA Technical Reports Server (NTRS)
Hamrock, B. J.
1973-01-01
The motion of the ball and sliding friction in an arched outer race ball bearing under thrust loads is determined. Fatigue life evaluations were made. The analysis is applied to a 150 millimeter bore ball bearing. The results indicated that for high speed-light load applications the arched bearing has significant improvement in fatigue life over that of a conventional bearing. An arching of 0.254 mm (0.01 in.) was found to be an optimal. For an arched bearing it was also found that a considerable amount of spinning occurs at the outer race contacts.
Ball motion and sliding friction in an arched outer race ball bearing
NASA Technical Reports Server (NTRS)
Hamrock, B. J.
1974-01-01
The motion of the ball and sliding friction in an arched outer-race ball bearing under thrust load is determined. Fatigue life evaluations were made. The analysis is applied to a 150 millimeter bore ball bearing. The results indicated that for high speed-light load applications the arched bearing has significant improvement in fatigue life over that of a conventional bearing. An arching of 0.254 mm (0.01 in.) was found to be an optimal. For an arched bearing it was also found that a considerable amount of spinning occurs at the outer race contacts.
A research on motion design for APP's loading pages based on time perception
NASA Astrophysics Data System (ADS)
Cao, Huai; Hu, Xiaoyun
2018-04-01
Due to restrictions caused by objective reasons like network bandwidth, hardware performance and etc., waiting is still an inevitable phenomenon that appears in our using mobile-terminal products. Relevant researches show that users' feelings in a waiting scenario can affect their evaluations on the whole product and services the product provides. With the development of user experience and inter-facial design subjects, the role of motion effect in the interface design has attracted more and more scholars' attention. In the current studies, the research theory of motion design in a waiting scenario is imperfect. This article will use the basic theory and experimental research methods of cognitive psychology to explore the motion design's impact on user's time perception when users are waiting for loading APP pages. Firstly, the article analyzes the factors that affect waiting experience of loading APP pages based on the theory of time perception, and then discusses motion design's impact on the level of time-perception when loading pages and its design strategy. Moreover, by the operation analysis of existing loading motion designs, the article classifies the existing loading motions and designs an experiment to verify the impact of different types of motions on the user's time perception. The result shows that the waiting time perception of mobile's terminals' APPs is related to the loading motion types, the combination type of loading motions can effectively shorten the waiting time perception as it scores a higher mean value in the length of time perception.
Kaplan, Janna; Ventura, Joel; Bakshi, Avijit; Pierobon, Alberto; Lackner, James R; DiZio, Paul
2017-01-01
Our goal was to determine how sleep deprivation, nauseogenic motion, and a combination of motion and sleep deprivation affect cognitive vigilance, visual-spatial perception, motor learning and retention, and balance. We exposed four groups of subjects to different combinations of normal 8h sleep or 4h sleep for two nights combined with testing under stationary conditions or during 0.28Hz horizontal linear oscillation. On the two days following controlled sleep, all subjects underwent four test sessions per day that included evaluations of fatigue, motion sickness, vigilance, perceptual discrimination, perceptual learning, motor performance and learning, and balance. Sleep loss and exposure to linear oscillation had additive or multiplicative relationships to sleepiness, motion sickness severity, decreases in vigilance and in perceptual discrimination and learning. Sleep loss also decelerated the rate of adaptation to motion sickness over repeated sessions. Sleep loss degraded the capacity to compensate for novel robotically induced perturbations of reaching movements but did not adversely affect adaptive recovery of accurate reaching. Overall, tasks requiring substantial attention to cognitive and motor demands were degraded more than tasks that were more automatic. Our findings indicate that predicting performance needs to take into account in addition to sleep loss, the attentional demands and novelty of tasks, the motion environment in which individuals will be performing and their prior susceptibility to motion sickness during exposure to provocative motion stimulation. Copyright © 2016 Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-07-01
... DISABILITIES Disability Ratings The Musculoskeletal System § 4.59 Painful motion. With any form of arthritis... manipulation, should be carefully noted and definitely related to affected joints. Muscle spasm will greatly...
Code of Federal Regulations, 2010 CFR
2010-07-01
... DISABILITIES Disability Ratings The Musculoskeletal System § 4.59 Painful motion. With any form of arthritis... manipulation, should be carefully noted and definitely related to affected joints. Muscle spasm will greatly...
Code of Federal Regulations, 2014 CFR
2014-07-01
... DISABILITIES Disability Ratings The Musculoskeletal System § 4.59 Painful motion. With any form of arthritis... manipulation, should be carefully noted and definitely related to affected joints. Muscle spasm will greatly...
Code of Federal Regulations, 2013 CFR
2013-07-01
... DISABILITIES Disability Ratings The Musculoskeletal System § 4.59 Painful motion. With any form of arthritis... manipulation, should be carefully noted and definitely related to affected joints. Muscle spasm will greatly...
Code of Federal Regulations, 2012 CFR
2012-07-01
... DISABILITIES Disability Ratings The Musculoskeletal System § 4.59 Painful motion. With any form of arthritis... manipulation, should be carefully noted and definitely related to affected joints. Muscle spasm will greatly...
A Simon Effect With Stationary Moving Stimuli
ERIC Educational Resources Information Center
Bosbach, Simone; Prinz, Wolfgang; Kerzel, Dirk
2004-01-01
To clarify whether motion information per se has a separable influence on action control, the authors investigated whether irrelevant direction of motion of stimuli whose overall position was constant over time would affect manual left-right responses (i.e., reveal a motion-based Simon effect). In Experiments 1 and 2, significant Simon effects…
Generation of Shear Motion from an Isotropic Explosion Source by Scattering in Heterogeneous Media
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirakawa, Evan; Pitarka, Arben; Mellors, Robert
One challenging task in explosion seismology is the development of physical models for explaining the generation of S waves during underground explosions. Recent analysis of ground motion from chemical explosions during the Source Physics Experiment (Pitarka et al., 2015) suggests that, although a large component of shear motion was generated directly at the source, additional scattering from heterogeneous velocity structure and topography is necessary to better match the recorded data. In our paper, we used a stochastic representation of small-scale velocity variability to produce high-frequency scattering and to analyze its implication on shear-motion generation during underground explosions. In our stochasticmore » velocity model, the key parameters that affect scattering are the correlation length and the relative amplitude of velocity perturbations. Finally, based on finite-difference simulations of elastic wave propagation from an isotropic explosion source, we find that higher velocity perturbations result in larger shear motion, whereas the correlation length, which controls the scatterers size, affects the frequency range at which relative transverse motion is larger.« less
Generation of Shear Motion from an Isotropic Explosion Source by Scattering in Heterogeneous Media
Hirakawa, Evan; Pitarka, Arben; Mellors, Robert
2016-07-19
One challenging task in explosion seismology is the development of physical models for explaining the generation of S waves during underground explosions. Recent analysis of ground motion from chemical explosions during the Source Physics Experiment (Pitarka et al., 2015) suggests that, although a large component of shear motion was generated directly at the source, additional scattering from heterogeneous velocity structure and topography is necessary to better match the recorded data. In our paper, we used a stochastic representation of small-scale velocity variability to produce high-frequency scattering and to analyze its implication on shear-motion generation during underground explosions. In our stochasticmore » velocity model, the key parameters that affect scattering are the correlation length and the relative amplitude of velocity perturbations. Finally, based on finite-difference simulations of elastic wave propagation from an isotropic explosion source, we find that higher velocity perturbations result in larger shear motion, whereas the correlation length, which controls the scatterers size, affects the frequency range at which relative transverse motion is larger.« less
Bioavailability of Promethazine during Spaceflight
NASA Technical Reports Server (NTRS)
Boyd, Jason L.; Wang, Zuwei; Putcha, Lakshmi
2009-01-01
Promethazine (PMZ) is the choice anti-motion sickness medication for treating space motion sickness (SMS) during flight. The side effects associated with PMZ include dizziness, drowsiness, sedation, and impaired psychomotor performance which could impact crew performance and mission operations. Early anecdotal reports from crewmembers indicate that these central nervous system side effects of PMZ are absent or greatly attenuated in microgravity, potentially due to changes in pharmacokinetics (PK) and pharmacodynamics in microgravity. These changes could also affect the therapeutic effectiveness of drugs in general and PMZ, in particular. In this investigation, we examined bioavailability and associated pharmacokinetics of PMZ in astronauts during and after space flight. Methods. Nine astronauts received, per their preference, PMZ (25 or 50 mg as intramuscular injection, oral tablet, or rectal suppository) on flight day one for the treatment of SMS and subsequently collected saliva samples and completed sleepiness scores for 72 h post dose. Thirty days after the astronauts returned to Earth, they repeated the protocol. Bioavailability and PK parameters were calculated and compared between flight and ground. Results. Maximum concentration (Cmax) was lower and time to reach Cmax (tmax) was longer in flight than on the ground. Area under the curve (AUC), a measure of bioavailability, was lower and biological half-life (t1/2) was longer in flight than on the ground. Conclusion. Results indicate that bioavailability of PMZ is reduced during spaceflight. Number of samples, sampling method, and sampling schedule significantly affected PK parameter estimates.
Pavan, Andrea; Ghin, Filippo; Donato, Rita; Campana, Gianluca; Mather, George
2017-08-15
A long-held view of the visual system is that form and motion are independently analysed. However, there is physiological and psychophysical evidence of early interaction in the processing of form and motion. In this study, we used a combination of Glass patterns (GPs) and repetitive Transcranial Magnetic Stimulation (rTMS) to investigate in human observers the neural mechanisms underlying form-motion integration. GPs consist of randomly distributed dot pairs (dipoles) that induce the percept of an oriented stimulus. GPs can be either static or dynamic. Dynamic GPs have both a form component (i.e., orientation) and a non-directional motion component along the orientation axis. GPs were presented in two temporal intervals and observers were asked to discriminate the temporal interval containing the most coherent GP. rTMS was delivered over early visual area (V1/V2) and over area V5/MT shortly after the presentation of the GP in each interval. The results showed that rTMS applied over early visual areas affected the perception of static GPs, but the stimulation of area V5/MT did not affect observers' performance. On the other hand, rTMS was delivered over either V1/V2 or V5/MT strongly impaired the perception of dynamic GPs. These results suggest that early visual areas seem to be involved in the processing of the spatial structure of GPs, and interfering with the extraction of the global spatial structure also affects the extraction of the motion component, possibly interfering with early form-motion integration. However, visual area V5/MT is likely to be involved only in the processing of the motion component of dynamic GPs. These results suggest that motion and form cues may interact as early as V1/V2. Copyright © 2017 Elsevier Inc. All rights reserved.
2015-09-30
phone: +44 1334 462624 fax: +44 1334 463443 e-mail: markjohnson@st-andrews.ac.uk Todd Lindstrom Wildlife Computers 8345 154th Avenue NE...in situ processing algorithms for sound and motion data. In a parallel project Dr. Andrews at the Alaska SeaLife Center teamed with Wildlife ...from Wildlife Computers to produce a highly integrated Sound and Motion Recording and Telemetry (SMRT) tag. The complete tag development is expected
Kong, Lingyu; Zhao, Yunshan; Dasgupta, Binayak; Ren, Yi; Hippalgaonkar, Kedar; Li, Xiuling; Chim, Wai Kin; Chiam, Sing Yang
2017-06-21
The instability of isolate catalysts during metal-assisted chemical etching is a major hindrance to achieve high aspect ratio structures in the vertical and directional etching of silicon (Si). In this work, we discussed and showed how isolate catalyst motion can be influenced and controlled by the semiconductor doping type and the oxidant concentration ratio. We propose that the triggering event in deviating isolate catalyst motion is brought about by unequal etch rates across the isolate catalyst. This triggering event is indirectly affected by the oxidant concentration ratio through the etching rates. While the triggering events are stochastic, the doping concentration of silicon offers a good control in minimizing isolate catalyst motion. The doping concentration affects the porosity at the etching front, and this directly affects the van der Waals (vdWs) forces between the metal catalyst and Si during etching. A reduction in the vdWs forces resulted in a lower bending torque that can prevent the straying of the isolate catalyst from its directional etching, in the event of unequal etch rates. The key understandings in isolate catalyst motion derived from this work allowed us to demonstrate the fabrication of large area and uniformly ordered sub-500 nm nanoholes array with an unprecedented high aspect ratio of ∼12.
Motion onset does not capture attention when subsequent motion is "smooth".
Sunny, Meera Mary; von Mühlenen, Adrian
2011-12-01
Previous research on the attentional effects of moving objects has shown that motion per se does not capture attention. However, in later studies it was argued that the onset of motion does capture attention. Here, we show that this motion-onset effect critically depends on motion jerkiness--that is, the rate at which the moving stimulus is refreshed. Experiment 1 used search displays with a static, a motion-onset, and an abrupt-onset stimulus, while systematically varying the refresh rate of the moving stimulus. The results showed that motion onset only captures attention when subsequent motion is jerky (8 and 17 Hz), not when it is smooth (33 and 100 Hz). Experiment 2 replaced motion onset with continuous motion, showing that motion jerkiness does not affect how continuous motion is processed. These findings do not support accounts that assume a special role for motion onset, but they are in line with the more general unique-event account.
Calamita, Simone Aparecida Penimpedo; Biasotto-Gonzalez, Daniela Aparecida; De Melo, Nivea Cristina; dos Santos, Douglas Meira; de Lassa, Roberta; de Mendonça, Fabiana Sarilho; Oliveira, Claudia Santos; Amorim, César Ferreira; Gonzalez, Tabajara Oliveira; Fumagalli, Marco Antônio; de Gomes, Cid André Fidelis Paula; Politti, Fabiano
2015-03-19
Nonspecific neck pain can cause considerable suffering, possible disability and reductions in quality of life and productivity. The aim of the proposed study is to evaluate the immediate effect of acupuncture on pain, cervical range of motion and electromyographic activity of the upper trapezius muscle in patients with nonspecific neck pain. A total of 12 patients with nonspecific neck pain and 12 healthy subjects will be enrolled in a randomized, single-blind crossover study. Each subject will receive two forms of treatment in random order: a single session of traditional acupuncture (acupoints: triple energizer 5, 'Wai-guan' and large intestine 11, 'Qu-chi') and sham acupuncture. To eliminate carry-over treatment effects, a one-week wash-out period will be respected between sessions. Surface electromyography will be used to determine motor control in the upper trapezius muscle before and after treatment. The outcome measures in the group with neck pain will be a numerical pain rating scale (range: 0 (no pain) to 10 (maximum pain)), documentation of the pain area on a body chart and cervical range of motion. Comparisons before and after acupuncture treatment will demonstrate whether acupoints affect the activity of the upper trapezius muscle, pain and cervical range of motion. The purpose of this randomized clinical trial is to evaluate the immediate effect of acupuncture on pain, cervical range of motion and electromyographic activity of the upper trapezius muscle in patients with nonspecific neck pain. Data will be published after the study is completed. The study will support the practice of evidence-based physical therapy for individuals with nonspecific neck pain. This trial was registered with Clinicaltrials.gov (identifier: NCT0984021 ) on 7 November 2013 ( https://clinicaltrials.gov/ct2/show/NCT01984021 ).
Boonruab, Jurairat; Nimpitakpong, Netraya; Damjuti, Watchara
2018-01-01
This randomized controlled trial aimed to investigate the distinctness after treatment among hot herbal compress, hot compress, and topical diclofenac. The registrants were equally divided into groups and received the different treatments including hot herbal compress, hot compress, and topical diclofenac group, which served as the control group. After treatment courses, Visual Analog Scale and 36-Item Short Form Health survey were, respectively, used to establish the level of pain intensity and quality of life. In addition, cervical range of motion and pressure pain threshold were also examined to identify the motional effects. All treatments showed significantly decreased level of pain intensity and increased cervical range of motion, while the intervention groups exhibited extraordinary capability compared with the topical diclofenac group in pressure pain threshold and quality of life. In summary, hot herbal compress holds promise to be an efficacious treatment parallel to hot compress and topical diclofenac.
Range of motion of diabetic frozen shoulder recovers to the contralateral level
Vastamäki, Heidi; Ristolainen, Leena
2016-01-01
Objective To determine whether frozen shoulder heals equally well in patients with and without diabetes and whether dependency on insulin affects the outcome. Methods We retrospectively examined 178 patients with idiopathic frozen shoulder; 27 patients had diabetes. We evaluated range of motion, pain, and functional results. The mean follow-up was 9.7 years (SD, 7.1 years). Results In the presence of frozen shoulder, range of motion did not differ between patients with and without diabetes. At follow-up, range of motion in all directions of both the affected and unaffected shoulders of patients with diabetes was inferior to that of patients without diabetes. Among patients with diabetes, range of motion of the once-frozen shoulder reached the level of the unaffected shoulder. Patients with and without diabetes experienced similar pain except during exertion. The Constant–Murley score was not significantly different between the two groups, and insulin dependency did not lead to worse outcomes. Conclusion Frozen shoulder heals well in patients with diabetes. PMID:27856934
Thought Speed, Mood, and the Experience of Mental Motion.
Pronin, Emily; Jacobs, Elana
2008-11-01
This article presents a theoretical account relating thought speed to mood and psychological experience. Thought sequences that occur at a fast speed generally induce more positive affect than do those that occur slowly. Thought speed constitutes one aspect of mental motion. Another aspect involves thought variability, or the degree to which thoughts in a sequence either vary widely from or revolve closely around a theme. Thought sequences possessing more motion (occurring fast and varying widely) generally produce more positive affect than do sequences possessing little motion (occurring slowly and repetitively). When speed and variability oppose each other, such that one is low and the other is high, predictable psychological states also emerge. For example, whereas slow, repetitive thinking can prompt dejection, fast, repetitive thinking can prompt anxiety. This distinction is related to the fact that fast thinking involves greater actual and felt energy than slow thinking does. Effects of mental motion occur independent of the specific content of thought. Their consequences for mood and energy hold psychotherapeutic relevance. © 2008 Association for Psychological Science.
Li, Zhi; Milutinović, Dejan; Rosen, Jacob
2017-05-01
Reach-to-grasp arm postures differ from those in pure reaching because they are affected by grasp position/orientation, rather than simple transport to a position during a reaching motion. This paper investigates this difference via an analysis of experimental data collected on reaching and reach-to-grasp motions. A seven-degree-of-freedom (DOFs) kinematic arm model with the swivel angle is used for the motion analysis. Compared to a widely used anatomical arm model, this model distinguishes clearly the four grasping-relevant DOFs (GR-DOFs) that are affected by positions and orientations of the objects to be grasped. These four GR-DOFs include the swivel angle that measures the elbow rotation about the shoulder-wrist axis, and three wrist joint angles. For each GR-DOF, we quantify position vs orientation task-relevance bias that measures how much the DOF is affected by the grasping position vs orientation. The swivel angle and forearm supination have similar bias, and the analysis of their motion suggests two hypotheses regarding the synergistic coordination of the macro- and micro-structures of the human arm (1) DOFs with similar task-relevance are synergistically coordinated; and (2) such synergy breaks when a task-relevant DOF is close to its joint limit without necessarily reaching the limit. This study provides a motion analysis method to reduce the control complexity for reach-to-grasp tasks, and suggests using dynamic coupling to coordinate the hand and arm of upper-limb exoskeletons.
Advancing the dual reciprocating drill design for efficient planetary subsurface exploration
NASA Astrophysics Data System (ADS)
Pitcher, Craig
Accessing the subsurface of planetary bodies with drilling systems is vital for furthering our understanding of the solar system and in the search for life and volatiles. The extremely stringent mass and sizing mission constraints have led to the examination of novel low-mass drilling techniques. One such system is the Dual-Reciprocating Drill (DRD), inspired by the ovipositor of the sirex noctilio, which uses the reciprocation of two halves lined with backwards-facing teeth to engage with and grip the surrounding substrate. For the DRD to become a viable alternative technique, further work is required to expand its testing, improve its efficiency and evolve it from the current proof-of-concept to a system prototype. To do this, three areas of research were identified. This involved examining how the drill head design affects the drilling depth, exploring the effects of ice content in regolith on its properties and drilling performance, and determining the benefits of additional controlled lateral motions in an integrated actuation mechanism. The tests performed in this research revealed that the cross-sectional area of the drill head was by far the most significant geometrical parameter with regards to drilling performance, while the teeth shape had a negligible effect. An ice content of 5 +/- 1% in the regolith corresponded to an increase in drilling time and a clear change in the regolith's physical properties. Finally, it was demonstrated that the addition of lateral motions allowed the drill to achieve greater depths. This work has advanced both the understanding and design of the DRD considerably. It has continued the exploration of the geometrical and substrate parameters that affect drilling performance and provided the first characterisation of the properties of an icy lunar polar simulant. The construction and testing of the complex motion internal actuation mechanism has both evolved the DRD design and opened a new avenue through which the system can be further optimised.
Investigating motion sickness using the conditioned taste aversion paradigm
NASA Technical Reports Server (NTRS)
Fox, Robert A.
1990-01-01
The use of conditioned taste aversion (CTA) to study motion sickness is reviewed. The use of CTA to measure motion sickness is supported by studies showing that an intact vestibular system is essential for the production of CTA when motion is the unconditioned stimulus. The magnitude of CTA is assessed at a time removed from exposure to motion, and therefore is not affected by residual effects of motion. Since the magnitude of CTA is assessed as volume or weight of flood or fluid, the degree of sickness is reflected in a continuous measure rather than in the discrete, all-or-none fashion characteristic of vomiting.
Motion of Solid Grains During Magnetic Field-Assisted Directional Solidification
NASA Astrophysics Data System (ADS)
Wang, Jiang; Lin, Xin; Fautrelle, Yves; Nguyen-Thi, Henri; Ren, Zhongming
2018-06-01
In this paper, we report the visible evidence for thermoelectric magnetic forces (TEMFs) during magnetic field-assisted directional solidification, and their potential to control the motion of solid grains (dendrite fragments or equiaxed grains). These motions are observed by means of synchrotron X-ray radiography and compared with analytic calculations for a spherical particle's motion driven only by TEMFs, which confirms that the observed solid grain motions are the combined result of the TEMFs and gravity. We also carried out corresponding 3D numerical simulations to validate the calculations and further prove our conclusion that TEMF acts on the solid grain and affects its motion trajectory.
Revisions to some parameters used in stochastic-method simulations of ground motion
Boore, David; Thompson, Eric M.
2015-01-01
The stochastic method of ground‐motion simulation specifies the amplitude spectrum as a function of magnitude (M) and distance (R). The manner in which the amplitude spectrum varies with M and R depends on physical‐based parameters that are often constrained by recorded motions for a particular region (e.g., stress parameter, geometrical spreading, quality factor, and crustal amplifications), which we refer to as the seismological model. The remaining ingredient for the stochastic method is the ground‐motion duration. Although the duration obviously affects the character of the ground motion in the time domain, it also significantly affects the response of a single‐degree‐of‐freedom oscillator. Recently published updates to the stochastic method include a new generalized double‐corner‐frequency source model, a new finite‐fault correction, a new parameterization of duration, and a new duration model for active crustal regions. In this article, we augment these updates with a new crustal amplification model and a new duration model for stable continental regions. Random‐vibration theory (RVT) provides a computationally efficient method to compute the peak oscillator response directly from the ground‐motion amplitude spectrum and duration. Because the correction factor used to account for the nonstationarity of the ground motion depends on the ground‐motion amplitude spectrum and duration, we also present new RVT correction factors for both active and stable regions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lips, Irene M., E-mail: i.m.lips@umcutrecht.nl; Gils, Carla H. van; Kotte, Alexis N.T.J.
2012-06-01
Purpose: To investigate whether magnesium oxide during external-beam radiotherapy for prostate cancer reduces intrafraction prostate motion in a double-blind, placebo-controlled randomized trial. Methods and Materials: At the Department of Radiotherapy, prostate cancer patients scheduled for intensity-modulated radiotherapy (77 Gy in 35 fractions) using fiducial marker-based position verification were randomly assigned to receive magnesium oxide (500 mg twice a day) or placebo during radiotherapy. The primary outcome was the proportion of patients with clinically relevant intrafraction prostate motion, defined as the proportion of patients who demonstrated in {>=}50% of the fractions an intrafraction motion outside a range of 2 mm. Secondarymore » outcome measures included quality of life and acute toxicity. Results: In total, 46 patients per treatment arm were enrolled. The primary endpoint did not show a statistically significant difference between the treatment arms with a percentage of patients with clinically relevant intrafraction motion of 83% in the magnesium oxide arm as compared with 80% in the placebo arm (p = 1.00). Concerning the secondary endpoints, exploratory analyses demonstrated a trend towards worsened quality of life and slightly more toxicity in the magnesium oxide arm than in the placebo arm; however, these differences were not statistically significant. Conclusions: Magnesium oxide is not effective in reducing the intrafraction prostate motion during external-beam radiotherapy, and therefore there is no indication to use it in clinical practice for this purpose.« less
Head motion during MRI acquisition reduces gray matter volume and thickness estimates.
Reuter, Martin; Tisdall, M Dylan; Qureshi, Abid; Buckner, Randy L; van der Kouwe, André J W; Fischl, Bruce
2015-02-15
Imaging biomarkers derived from magnetic resonance imaging (MRI) data are used to quantify normal development, disease, and the effects of disease-modifying therapies. However, motion during image acquisition introduces image artifacts that, in turn, affect derived markers. A systematic effect can be problematic since factors of interest like age, disease, and treatment are often correlated with both a structural change and the amount of head motion in the scanner, confounding the ability to distinguish biology from artifact. Here we evaluate the effect of head motion during image acquisition on morphometric estimates of structures in the human brain using several popular image analysis software packages (FreeSurfer 5.3, VBM8 SPM, and FSL Siena 5.0.7). Within-session repeated T1-weighted MRIs were collected on 12 healthy volunteers while performing different motion tasks, including two still scans. We show that volume and thickness estimates of the cortical gray matter are biased by head motion with an average apparent volume loss of roughly 0.7%/mm/min of subject motion. Effects vary across regions and remain significant after excluding scans that fail a rigorous quality check. In view of these results, the interpretation of reported morphometric effects of movement disorders or other conditions with increased motion tendency may need to be revisited: effects may be overestimated when not controlling for head motion. Furthermore, drug studies with hypnotic, sedative, tranquilizing, or neuromuscular-blocking substances may contain spurious "effects" of reduced atrophy or brain growth simply because they affect motion distinct from true effects of the disease or therapeutic process. Copyright © 2014 Elsevier Inc. All rights reserved.
Young Children with Autism Spectrum Disorder Do Not Preferentially Attend to Biological Motion
ERIC Educational Resources Information Center
Annaz, Dagmara; Campbell, Ruth; Coleman, Mike; Milne, Elizabeth; Swettenham, John
2012-01-01
Preferential attention to biological motion can be seen in typically developing infants in the first few days of life and is thought to be an important precursor in the development of social communication. We examined whether children with autism spectrum disorder (ASD) aged 3-7 years preferentially attend to point-light displays depicting…
Teaching an Old Robot New Tricks: Learning Novel Tasks via Interaction with People and Things
2003-06-01
visions behind the Cog Project were to build a "robot baby ", which could interact with people and objects, imitate the motions of its teachers, and even...though. A very elaborate animatronic motor controller can produce very life-like canned motion, although the controller itself bears little resemblance
Motion on an Inclined Plane and the Nature of Science
ERIC Educational Resources Information Center
Pendrill, Ann-Marie; Ekström, Peter; Hansson, Lena; Mars, Patrik; Ouattara, Lassana; Ryan, Ulrika
2014-01-01
Friction is an important phenomenon in everyday life. All children are familiar with playground slides, which may thus be a good starting point for investigating friction. Motion on an inclined plane is a standard physics example. This paper presents an investigation of friction by a group of 11-year olds. How did they plan their investigations?…
NASA Astrophysics Data System (ADS)
Sun, Zhuangzhi; Zhao, Gang; Qiao, Dongpan; Song, Wenlong
2017-12-01
Artificial muscles have attracted great attention for their potentials in intelligent robots, biomimetic devices, and micro-electromechanical system. However, there are many performance bottlenecks restricting the development of artificial muscles in engineering applications, e.g., the little blocking force and short working life. Focused on the larger requirements of the output force and the lack characteristics of the linear motion, an innovative muscle-like linear actuator based on two segmented IPMC strips was developed to imitate linear motion of artificial muscles. The structures of the segmented IPMC strip of muscle-like linear actuator were developed and the established mathematical model was to determine the appropriate segmented proportion as 1:2:1. The muscle-like linear actuator with two segmented IPMC strips assemble by two supporting link blocks was manufactured for the study of electromechanical properties. Electromechanical properties of muscle-like linear actuator under the different technological factors were obtained to experiment, and the corresponding changing rules of muscle-like linear actuators were presented to research. Results showed that factors of redistributed resistance and surface strain on both end-sides were two main reasons affecting the emergence of different electromechanical properties of muscle-like linear actuators.
Kinetic energy budgets during the life cycle of intense convective activity
NASA Technical Reports Server (NTRS)
Fuelberg, H. E.; Scoggins, J. R.
1978-01-01
Synoptic-scale data at three- and six-hour intervals are employed to study the relationship between changing kinetic energy variables and the life cycles of two severe squall lines. The kinetic energy budgets indicate a high degree of kinetic energy generation, especially pronounced near the jet-stream level. Energy losses in the storm environment are due to the transfer of kinetic energy from grid to subgrid scales of motion; large-scale upward vertical motion carries aloft the kinetic energy generated by storm activity at lower levels. In general, the time of maximum storm intensity is also the time of maximum energy conversion and transport.
Age and sex differences in ranges of motion and motion patterns.
Hwang, Jaejin; Jung, Myung-Chul
2015-01-01
This study investigated the effects of age and sex on joint ranges of motion (ROMs) and motion patterns. Forty participants performed 18 motions using eight body segments at self-selected speeds. Older subjects showed smaller ROMs than younger subjects for 11 motions; the greatest difference in ROM was 44.9% for eversion/inversion of the foot. Older subjects also required more time than younger subjects to approach the peak angular velocity for six motions. In contrast, sex significantly affected ROMs but not motion patterns. Male subjects exhibited smaller ROMs than female subjects for four motions; the greatest sex-dependent difference in ROM was 29.7% for ulnar/radial deviation of the hand. The age and sex effects depended on the specific segments used and motions performed, possibly because of differences in anatomical structures and frequencies of use of the joints in habitual physical activities between the groups.
Quantication and analysis of respiratory motion from 4D MRI
NASA Astrophysics Data System (ADS)
Aizzuddin Abd Rahni, Ashrani; Lewis, Emma; Wells, Kevin
2014-11-01
It is well known that respiratory motion affects image acquisition and also external beam radiotherapy (EBRT) treatment planning and delivery. However often the existing approaches for respiratory motion management are based on a generic view of respiratory motion such as the general movement of organ, tissue or fiducials. This paper thus aims to present a more in depth analysis of respiratory motion based on 4D MRI for further integration into motion correction in image acquisition or image based EBRT. Internal and external motion was first analysed separately, on a per-organ basis for internal motion. Principal component analysis (PCA) was then performed on the internal and external motion vectors separately and the relationship between the two PCA spaces was analysed. The motion extracted from 4D MRI on general was found to be consistent with what has been reported in literature.
Effect of pressure and padding on motion artifact of textile electrodes.
Cömert, Alper; Honkala, Markku; Hyttinen, Jari
2013-04-08
With the aging population and rising healthcare costs, wearable monitoring is gaining importance. The motion artifact affecting dry electrodes is one of the main challenges preventing the widespread use of wearable monitoring systems. In this paper we investigate the motion artifact and ways of making a textile electrode more resilient against motion artifact. Our aim is to study the effects of the pressure exerted onto the electrode, and the effects of inserting padding between the applied pressure and the electrode. We measure real time electrode-skin interface impedance, ECG from two channels, the motion artifact related surface potential, and exerted pressure during controlled motion by a measurement setup designed to estimate the relation of motion artifact to the signals. We use different foam padding materials with various mechanical properties and apply electrode pressures between 5 and 25 mmHg to understand their effect. A QRS and noise detection algorithm based on a modified Pan-Tompkins QRS detection algorithm estimates the electrode behaviour in respect to the motion artifact from two channels; one dominated by the motion artifact and one containing both the motion artifact and the ECG. This procedure enables us to quantify a given setup's susceptibility to the motion artifact. Pressure is found to strongly affect signal quality as is the use of padding. In general, the paddings reduce the motion artifact. However the shape and frequency components of the motion artifact vary for different paddings, and their material and physical properties. Electrode impedance at 100 kHz correlates in some cases with the motion artifact but it is not a good predictor of the motion artifact. From the results of this study, guidelines for improving electrode design regarding padding and pressure can be formulated as paddings are a necessary part of the system for reducing the motion artifact, and further, their effect maximises between 15 mmHg and 20 mmHg of exerted pressure. In addition, we present new methods for evaluating electrode sensitivity to motion, utilizing the detection of noise peaks that fall into the same frequency band as R-peaks.
NASA Astrophysics Data System (ADS)
Bai, Yang; Tofel, Pavel; Hadas, Zdenek; Smilek, Jan; Losak, Petr; Skarvada, Pavel; Macku, Robert
2018-06-01
The capability of using a linear kinetic energy harvester - A cantilever structured piezoelectric energy harvester - to harvest human motions in the real-life activities is investigated. The whole loop of the design, simulation, fabrication and test of the energy harvester is presented. With the smart wristband/watch sized energy harvester, a root mean square of the output power of 50 μW is obtained from the real-life hand-arm motion in human's daily life. Such a power is enough to make some low power consumption sensors to be self-powered. This paper provides a good and reliable comparison to those with nonlinear structures. It also helps the designers to consider whether to choose a nonlinear structure or not in a particular energy harvester based on different application scenarios.
Objective Motion Cueing Criteria Investigation Based on Three Flight Tasks
NASA Technical Reports Server (NTRS)
Zaal, Petrus M. T.; Schroeder, Jeffery A.; Chung, William W.
2015-01-01
This paper intends to help establish fidelity criteria to accompany the simulator motion system diagnostic test specified by the International Civil Aviation Organization. Twelve air- line transport pilots flew three tasks in the NASA Vertical Motion Simulator under four different motion conditions. The experiment used three different hexapod motion configurations, each with a different tradeoff between motion filter gain and break frequency, and one large motion configuration that utilized as much of the simulator's motion space as possible. The motion condition significantly affected: 1) pilot motion fidelity ratings, and sink rate and lateral deviation at touchdown for the approach and landing task, 2) pilot motion fidelity ratings, roll deviations, maximum pitch rate, and number of stick shaker activations in the stall task, and 3) heading deviation after an engine failure in the takeoff task. Significant differences in pilot-vehicle performance were used to define initial objective motion cueing criteria boundaries. These initial fidelity boundaries show promise but need refinement.
4D dose simulation in volumetric arc therapy: Accuracy and affecting parameters
Werner, René
2017-01-01
Radiotherapy of lung and liver lesions has changed from normofractioned 3D-CRT to stereotactic treatment in a single or few fractions, often employing volumetric arc therapy (VMAT)-based techniques. Potential unintended interference of respiratory target motion and dynamically changing beam parameters during VMAT dose delivery motivates establishing 4D quality assurance (4D QA) procedures to assess appropriateness of generated VMAT treatment plans when taking into account patient-specific motion characteristics. Current approaches are motion phantom-based 4D QA and image-based 4D VMAT dose simulation. Whereas phantom-based 4D QA is usually restricted to a small number of measurements, the computational approaches allow simulating many motion scenarios. However, 4D VMAT dose simulation depends on various input parameters, influencing estimated doses along with mitigating simulation reliability. Thus, aiming at routine use of simulation-based 4D VMAT QA, the impact of such parameters as well as the overall accuracy of the 4D VMAT dose simulation has to be studied in detail–which is the topic of the present work. In detail, we introduce the principles of 4D VMAT dose simulation, identify influencing parameters and assess their impact on 4D dose simulation accuracy by comparison of simulated motion-affected dose distributions to corresponding dosimetric motion phantom measurements. Exploiting an ITV-based treatment planning approach, VMAT treatment plans were generated for a motion phantom and different motion scenarios (sinusoidal motion of different period/direction; regular/irregular motion). 4D VMAT dose simulation results and dose measurements were compared by local 3% / 3 mm γ-evaluation, with the measured dose distributions serving as ground truth. Overall γ-passing rates of simulations and dynamic measurements ranged from 97% to 100% (mean across all motion scenarios: 98% ± 1%); corresponding values for comparison of different day repeat measurements were between 98% and 100%. Parameters of major influence on 4D VMAT dose simulation accuracy were the degree of temporal discretization of the dose delivery process (the higher, the better) and correct alignment of the assumed breathing phases at the beginning of the dose measurements and simulations. Given the high γ-passing rates between simulated motion-affected doses and dynamic measurements, we consider the simulations to provide a reliable basis for assessment of VMAT motion effects that–in the sense of 4D QA of VMAT treatment plans–allows to verify target coverage in hypofractioned VMAT-based radiotherapy of moving targets. Remaining differences between measurements and simulations motivate, however, further detailed studies. PMID:28231337
4D dose simulation in volumetric arc therapy: Accuracy and affecting parameters.
Sothmann, Thilo; Gauer, Tobias; Werner, René
2017-01-01
Radiotherapy of lung and liver lesions has changed from normofractioned 3D-CRT to stereotactic treatment in a single or few fractions, often employing volumetric arc therapy (VMAT)-based techniques. Potential unintended interference of respiratory target motion and dynamically changing beam parameters during VMAT dose delivery motivates establishing 4D quality assurance (4D QA) procedures to assess appropriateness of generated VMAT treatment plans when taking into account patient-specific motion characteristics. Current approaches are motion phantom-based 4D QA and image-based 4D VMAT dose simulation. Whereas phantom-based 4D QA is usually restricted to a small number of measurements, the computational approaches allow simulating many motion scenarios. However, 4D VMAT dose simulation depends on various input parameters, influencing estimated doses along with mitigating simulation reliability. Thus, aiming at routine use of simulation-based 4D VMAT QA, the impact of such parameters as well as the overall accuracy of the 4D VMAT dose simulation has to be studied in detail-which is the topic of the present work. In detail, we introduce the principles of 4D VMAT dose simulation, identify influencing parameters and assess their impact on 4D dose simulation accuracy by comparison of simulated motion-affected dose distributions to corresponding dosimetric motion phantom measurements. Exploiting an ITV-based treatment planning approach, VMAT treatment plans were generated for a motion phantom and different motion scenarios (sinusoidal motion of different period/direction; regular/irregular motion). 4D VMAT dose simulation results and dose measurements were compared by local 3% / 3 mm γ-evaluation, with the measured dose distributions serving as ground truth. Overall γ-passing rates of simulations and dynamic measurements ranged from 97% to 100% (mean across all motion scenarios: 98% ± 1%); corresponding values for comparison of different day repeat measurements were between 98% and 100%. Parameters of major influence on 4D VMAT dose simulation accuracy were the degree of temporal discretization of the dose delivery process (the higher, the better) and correct alignment of the assumed breathing phases at the beginning of the dose measurements and simulations. Given the high γ-passing rates between simulated motion-affected doses and dynamic measurements, we consider the simulations to provide a reliable basis for assessment of VMAT motion effects that-in the sense of 4D QA of VMAT treatment plans-allows to verify target coverage in hypofractioned VMAT-based radiotherapy of moving targets. Remaining differences between measurements and simulations motivate, however, further detailed studies.
1978-06-01
stimulate at-least three levels of crew function. At the most complex level, visual cues are used to discriminate the presence or activities of...limited to motion on- set cues washed out at subliminal levels.. Because of the cues they provide the driver, gunner, and commander, and the dis...motion, i.e.,which physiological receptors are affected, how they function,and how they may be stimulated by a simulator motion system. I Motion is
NASA Technical Reports Server (NTRS)
Cowings, Patricia S.; Toscano, William B.
1993-01-01
Finding an effective treatment for the motion sickness-like symptoms that occur in space has become a high priority for NASA. The background research is reviewed and the experimental design of a formal life sciences shuttle flight experiment designed to prevent space motion sickness in shuttle crew members is presented. This experiment utilizes a behavioral medicine approach to solving this problem. This method, Autogenic-Feedback Training (AFT), involves training subjects to voluntarily control several of their own physiological responses to environmental stressors. AFT has been used reliably to increase tolerance to motion sickness during ground-based tests in over 200 men and women under a variety of conditions that induce motion sickness, and preliminary evidence from space suggests that AFT may be an effective treatment for space motion sickness as well. Proposed changes to this experiment for future manifests are included.
Real-time weigh-in-motion measurement using fiber Bragg grating sensors
NASA Astrophysics Data System (ADS)
Huang, Ying; Palek, Leonard; Strommen, Robert; Worel, Ben; Chen, Genda
2014-03-01
Overloading truck loads have long been one of the key reasons for accelerating road damage, especially in rural regions where the design loads are expected to be small and in the cold regions where the wet-and-dry cycle places a significant role. To control the designed traffic loads and further guide the road design in future, periodical weight stations have been implemented for double check of the truck loads. The weight stations give chances for missing measurement of overloaded vehicles, slow down the traffic, and require additional labors. Infrastructure weight-in-motion sensors, on the other hand, keep consistent traffic flow and monitor all types of vehicles on roads. However, traditional electrical weight-in-motion sensors showed high electromagnetic interference (EMI), high dependence on environmental conditions such as moisture, and relatively short life cycle, which are unreliable for long-term weigh-inmotion measurements. Fiber Bragg grating (FBG) sensors, with unique advantages of compactness, immune to EMI and moisture, capability of quasi-distributed sensing, and long life cycle, will be a perfect candidate for long-term weigh-in-motion measurements. However, the FBG sensors also surfer from their frangible nature of glass materials for a good survive rate during sensor installation. In this study, the FBG based weight-in-motion sensors were packaged by fiber reinforced polymer (FRP) materials and further validated at MnROAD facility, Minnesota DOT (MnDOT). The design and layout of the FRP-FBG weight-in-motion sensors, their field test setup, data acquisition, and data analysis will be presented. Upon validation, the FRP-FBG sensors can be applied weigh-in-motion measurement to assistant road managements.
Historical Development of Newton's Laws of Motion and Suggestions for Teaching Content
ERIC Educational Resources Information Center
Chang, Wheijen; Bell, Beverley; Jones, Allister
2014-01-01
A review of the history of Newton's Laws of Motion illustrates that the historical development gradually shifted away from intuitive experiences and daily life conventions towards a scientific regulated perspective. Three stages of the historical development are discussed, i.e. prior to the Principia, the 3rd (last) edition of the Principia,…
Audiovisual associations alter the perception of low-level visual motion
Kafaligonul, Hulusi; Oluk, Can
2015-01-01
Motion perception is a pervasive nature of vision and is affected by both immediate pattern of sensory inputs and prior experiences acquired through associations. Recently, several studies reported that an association can be established quickly between directions of visual motion and static sounds of distinct frequencies. After the association is formed, sounds are able to change the perceived direction of visual motion. To determine whether such rapidly acquired audiovisual associations and their subsequent influences on visual motion perception are dependent on the involvement of higher-order attentive tracking mechanisms, we designed psychophysical experiments using regular and reverse-phi random dot motions isolating low-level pre-attentive motion processing. Our results show that an association between the directions of low-level visual motion and static sounds can be formed and this audiovisual association alters the subsequent perception of low-level visual motion. These findings support the view that audiovisual associations are not restricted to high-level attention based motion system and early-level visual motion processing has some potential role. PMID:25873869
Hybrid-PIC simulation of sputtering product distribution in a Hall thruster
NASA Astrophysics Data System (ADS)
Cao, Xifeng; Hang, Guanrong; Liu, Hui; Meng, Yingchao; Luo, Xiaoming; Yu, Daren
2017-10-01
Hall thrusters have been widely used in orbit correction and the station-keeping of geostationary satellites due to their high specific impulse, long life, and high reliability. During the operating life of a Hall thruster, high-energy ions will bombard the discharge channel and cause serious erosion. As time passes, this sputtering process will change the macroscopic surface morphology of the discharge channel, especially near the exit, thus affecting the performance of the thruster. Therefore, it is necessary to carry out research on the motion of the sputtering products and erosion process of the discharge wall. To better understand the moving characteristics of sputtering products, based on the hybrid particle-in-cell (PIC) numerical method, this paper simulates the different erosion states of the thruster discharge channel in different moments and analyzes the moving process of different particles, such as B atoms and B+ ions. In this paper, the main conclusion is that B atoms are mainly produced on both sides of the channel exit, and B+ ions are mainly produced in the middle of the channel exit. The ionization rate of B atoms is approximately 1%.
NASA Astrophysics Data System (ADS)
Lin, Jieqiong; Guan, Liang; Lu, Mingming; Han, Jinguo; Kan, Yudi
2017-12-01
In traditional diamond cutting, the cutting force is usually large and it will affect tool life and machining quality. Elliptical vibration cutting (EVC) as one of the ultra-precision machining technologies has a lot of advantages, such as reduces cutting force, extend tool life and so on. It's difficult to predict the transient cutting force of EVC due to its unique elliptical motion trajectory. Study on chip formation will helpfully to predict cutting force. The geometric feature of chip has important effects on cutting force, however, few scholars have studied the chip formation. In order to investigate the time-varying cutting force of EVC, the geometric feature model of chip is established based on analysis of chip formation, and the effects of cutting parameters on the geometric feature of chip are analyzed. To predict transient force quickly and effectively, the geometric feature of chip is introduced into the cutting force model. The calculated results show that the error between the predicted cutting force in this paper and that in the literature is less than 2%, which proves its feasibility.
Modeling perceived stress via HRV and accelerometer sensor streams.
Wu, Min; Cao, Hong; Nguyen, Hai-Long; Surmacz, Karl; Hargrove, Caroline
2015-08-01
Discovering and modeling of stress patterns of human beings is a key step towards achieving automatic stress monitoring, stress management and healthy lifestyle. As various wearable sensors become popular, it becomes possible for individuals to acquire their own relevant sensory data and to automatically assess their stress level on the go. Previous studies for stress analysis were conducted in the controlled laboratory and clinic settings. These studies are not suitable for stress monitoring in one's daily life as various physical activities may affect the physiological signals. In this paper, we address such issue by integrating two modalities of sensors, i.e., HRV sensors and accelerometers, to monitor the perceived stress levels in daily life. We gathered both the heart and the motion data from 8 participants continuously for about 2 weeks. We then extracted features from both sensory data and compared the existing machine learning methods for learning personalized models to interpret the perceived stress levels. Experimental results showed that Bagging classifier with feature selection is able to achieve a prediction accuracy 85.7%, indicating our stress monitoring on daily basis is fairly practical.
Hastrup, Kirsten; Mosbech, Anders; Grønnow, Bjarne
2018-04-01
The North Water is a recurrent polynya in the High Arctic situated between Northwest Greenland and Ellesmere Island of Canada. The North Water makes a dynamic space, where various processes may enhance or obstruct each other, accelerating or halting particular modes of human-animal relations in the region, where life itself depends on the North Water. This will be discussed in four steps. The first step posits the North Water as a perceived oasis for explorers and whalers hailing from Europe or America in the nineteenth century. The second step concentrates on the diverse rhythms inherent in the ice conditions, as affected by trends that are set in motion elsewhere. The third step highlights the implications of the dynamics of the ice and sea currents for animal life in the region. The fourth step gives an overview of human settlement patterns around the North Water across the ages. The article shows how natural and social features are deeply implicated in each other, even if they are not directly co-variant.
Learned Non-Rigid Object Motion is a View-Invariant Cue to Recognizing Novel Objects
Chuang, Lewis L.; Vuong, Quoc C.; Bülthoff, Heinrich H.
2012-01-01
There is evidence that observers use learned object motion to recognize objects. For instance, studies have shown that reversing the learned direction in which a rigid object rotated in depth impaired recognition accuracy. This motion reversal can be achieved by playing animation sequences of moving objects in reverse frame order. In the current study, we used this sequence-reversal manipulation to investigate whether observers encode the motion of dynamic objects in visual memory, and whether such dynamic representations are encoded in a way that is dependent on the viewing conditions. Participants first learned dynamic novel objects, presented as animation sequences. Following learning, they were then tested on their ability to recognize these learned objects when their animation sequence was shown in the same sequence order as during learning or in the reverse sequence order. In Experiment 1, we found that non-rigid motion contributed to recognition performance; that is, sequence-reversal decreased sensitivity across different tasks. In subsequent experiments, we tested the recognition of non-rigidly deforming (Experiment 2) and rigidly rotating (Experiment 3) objects across novel viewpoints. Recognition performance was affected by viewpoint changes for both experiments. Learned non-rigid motion continued to contribute to recognition performance and this benefit was the same across all viewpoint changes. By comparison, learned rigid motion did not contribute to recognition performance. These results suggest that non-rigid motion provides a source of information for recognizing dynamic objects, which is not affected by changes to viewpoint. PMID:22661939
ERIC Educational Resources Information Center
JOHNSON, EDWINA C.
THE MEANING OF INTEGRATION AND SOME CHANGES WHICH SHOULD OCCUR IN AMERICAN LIFE ARE EXAMINED. THE DEFAMATION OF THE NEGRO IN THE PRINTED WORD, NOVELS, MOTION PICTURES, AND PARTICULARLY IN SCHOOL TEXTBOOKS IS ILLUSTRATED. MANY TEXTBOOKS OMIT NEGRO CONTRIBUTIONS TO AMERICAN LIFE AND NULLIFY CHILDREN'S ASPIRATIONS BY RELEGATING NEGROES TO A PASSIVE…
Pharmacotherapeutic Aspects of Space Medicine
NASA Technical Reports Server (NTRS)
Putcha, Lakshmi
2004-01-01
Medications are used for a wide variety of indications during space flight. For example, astronauts have taken drugs in flight to ameliorate or prevent symptoms of space motion sickness, headache, sleeplessness, backache, nasal congestion, and constipation. Russian cosmonauts reportedly take medications to prevent metabolic disturbances of the myocardium and intestinal flora, and to optimize their work capacity. Although the discomfort associated with some acute responses to microgravity (e.g., space motion sickness) is expected to diminish with length of time in flight, other responses that have delayed onset (e.g., maintaining nutritional status, bone and muscle strength, and perhaps immune response) may affect health and quality of life during longer missions. Therefore, as the duration of space flights increases, the need for treatment with medications is expected to increase accordingly. Medications carried on Space Shuttle missions have varied somewhat from flight to flight, depending on the individual needs of the crewmembers. Medications use during Shuttle flights seems to be more prevalent than during earlier programs, perhaps because drugs are provided in easy-to-use forms. In fact, nearly all medications taken to date have been ingested orally in tablet form. However, given that the oral route may not be ideal for those suffering motion-sickness symptoms, intramuscular and intranasal preparations are being tested. For example, intramuscular administration of promethazine hydrochloride (Phenergan(Registered TradeMark)) has been reported to be more effective in alleviating motion-sickness symptoms. The difficulties involved in conducting definitive studies of drug efficacy during U.S. space flights have been compounded by the absence of a systematic approach to determining which drugs were taken by whom and under what circumstances. The use of some drugs in space has been less efficacious than expected. The onset, intensity, and duration of the response produced by any drug depend upon rates of absorption, distribution, metabolism, and elimination of the drug; space flight-induced changes in blood flow and the function of the gastrointestinal (GI) tract, liver, or kidneys may alter these processes. Another important aspect of clinical efficacy of medications in space is the stability of pharmaceuticals. As the U.S. space program is moving toward extended Space Shuttle flights and beyond, to space station missions and planetary explorations, understanding how space flight affects organ systems and clinical pharmacology is necessary to optimize pharmacotherapeutics in space and ensure adequate safety and health of crewmembers.
Cycle life machine for AX-5 space suit
NASA Technical Reports Server (NTRS)
Schenberger, Deborah S.
1990-01-01
In order to accurately test the AX-5 space suit, a complex series of motions needed to be performed which provided a unique opportunity for mechanism design. The cycle life machine design showed how 3-D computer images can enhance mechanical design as well as help in visualizing mechanisms before manufacturing them. In the early stages of the design, potential problems in the motion of the joint and in the four bar linkage system were resolved using CAD. Since these problems would have been very difficult and tedious to solve on a drawing board, they would probably not have been addressed prior to fabrication, thus limiting the final design or requiring design modification after fabrication.
Pilot-Induced Oscillation Prediction With Three Levels of Simulation Motion Displacement
NASA Technical Reports Server (NTRS)
Schroeder, Jeffery A.; Chung, William W. Y.; Tran, Duc T.; Laforce, Soren; Bengford, Norman J.
2001-01-01
Simulator motion platform characteristics were examined to determine if the amount of motion affects pilot-induced oscillation (PIO) prediction. Five test pilots evaluated how susceptible 18 different sets of pitch dynamics were to PIOs with three different levels of simulation motion platform displacement: large, small, and none. The pitch dynamics were those of a previous in-flight experiment, some of which elicited PIOs These in-flight results served as truth data for the simulation. As such, the in-flight experiment was replicated as much as possible. Objective and subjective data were collected and analyzed With large motion, PIO and handling qualities ratings matched the flight data more closely than did small motion or no motion. Also, regardless of the aircraft dynamics, large motion increased pilot confidence in assigning handling qualifies ratings, reduced safety pilot trips, and lowered touchdown velocities. While both large and small motion provided a pitch rate cue of high fidelity, only large motion presented the pilot with a high fidelity vertical acceleration cue.
Being Moved by the Self and Others: Influence of Empathy on Self-Motion Perception
Lopez, Christophe; Falconer, Caroline J.; Mast, Fred W.
2013-01-01
Background The observation of conspecifics influences our bodily perceptions and actions: Contagious yawning, contagious itching, or empathy for pain, are all examples of mechanisms based on resonance between our own body and others. While there is evidence for the involvement of the mirror neuron system in the processing of motor, auditory and tactile information, it has not yet been associated with the perception of self-motion. Methodology/Principal Findings We investigated whether viewing our own body, the body of another, and an object in motion influences self-motion perception. We found a visual-vestibular congruency effect for self-motion perception when observing self and object motion, and a reduction in this effect when observing someone else's body motion. The congruency effect was correlated with empathy scores, revealing the importance of empathy in mirroring mechanisms. Conclusions/Significance The data show that vestibular perception is modulated by agent-specific mirroring mechanisms. The observation of conspecifics in motion is an essential component of social life, and self-motion perception is crucial for the distinction between the self and the other. Finally, our results hint at the presence of a “vestibular mirror neuron system”. PMID:23326302
Cömert, Alper; Hyttinen, Jari
2015-05-15
With advances in technology and increasing demand, wearable biosignal monitoring is developing and new applications are emerging. One of the main challenges facing the widespread use of wearable monitoring systems is the motion artifact. The sources of the motion artifact lie in the skin-electrode interface. Reducing the motion and deformation at this interface should have positive effects on signal quality. In this study, we aim to investigate whether the structure supporting the electrode can be designed to reduce the motion artifact with the hypothesis that this can be achieved by stabilizing the skin deformations around the electrode. We compare four textile electrodes with different support structure designs: a soft padding larger than the electrode area, a soft padding larger than the electrode area with a novel skin deformation restricting design, a soft padding the same size as the electrode area, and a rigid support the same size as the electrode. With five subjects and two electrode locations placed over different kinds of tissue at various mounting forces, we simultaneously measured the motion artifact, a motion affected ECG, and the real-time skin-electrode impedance during the application of controlled motion to the electrodes. The design of the electrode support structure has an effect on the generated motion artifact; good design with a skin stabilizing structure makes the electrodes physically more motion artifact resilient, directly affecting signal quality. Increasing the applied mounting force shows a positive effect up to 1,000 gr applied force. The properties of tissue under the electrode are an important factor in the generation of the motion artifact and the functioning of the electrodes. The relationship of motion artifact amplitude to the electrode movement magnitude is seen to be linear for smaller movements. For larger movements, the increase of motion generated a disproportionally larger artifact. The motion artifact and the induced impedance change were caused by the electrode motion and contained the same frequency components as the applied electrode motion pattern. We found that stabilizing the skin around the electrode using an electrode structure that manages to successfully distribute the force and movement to an area beyond the borders of the electrical contact area reduces the motion artifact when compared to structures that are the same size as the electrode area.
ERIC Educational Resources Information Center
Brunkan, Melissa C.
2016-01-01
The purpose of this study was to validate previous research that suggests using movement in conjunction with singing tasks can affect intonation and perception of the task. Singers (N = 49) were video and audio recorded, using a motion capture system, while singing a phrase from a familiar song, first with no motion, and then while doing a low,…
Autogenic feedback training experiment: A preventative method for space motion sickness
NASA Technical Reports Server (NTRS)
Cowings, Patricia S.
1993-01-01
Space motion sickness is a disorder which produces symptoms similar to those of motion sickness on Earth. This syndrome has affected approximately 50 percent of all astronauts and cosmonauts exposed to microgravity in space, but it differs from what is commonly known as motion sickness in a number of critical ways. There is currently no ground-based method for predicting susceptibility to motion sickness in space. Antimotion sickness drugs have had limited success in preventing or counteracting symptoms in space, and frequently caused debilitating side effects. The objectives were: (1) to evaluate the effectiveness of Autogenic-Feedback Training as a countermeasure for space motion sickness; (2) to compare physiological data and in-flight symptom reports to ground-based motion sickness data; and (3) to predict susceptibility to space motion sickness based on pre-flight data of each treatment group crew member.
Integrative cortical dysfunction and pervasive motion perception deficit in fragile X syndrome.
Kogan, C S; Bertone, A; Cornish, K; Boutet, I; Der Kaloustian, V M; Andermann, E; Faubert, J; Chaudhuri, A
2004-11-09
Fragile X syndrome (FXS) is associated with neurologic deficits recently attributed to the magnocellular pathway of the lateral geniculate nucleus. To test the hypotheses that FXS individuals 1) have a pervasive visual motion perception impairment affecting neocortical circuits in the parietal lobe and 2) have deficits in integrative neocortical mechanisms necessary for perception of complex stimuli. Psychophysical tests of visual motion and form perception defined by either first-order (luminance) or second-order (texture) attributes were used to probe early and later occipito-temporal and occipito-parietal functioning. When compared to developmental- and age-matched controls, FXS individuals displayed severe impairments in first- and second-order motion perception. This deficit was accompanied by near normal perception for first-order form stimuli but not second-order form stimuli. Impaired visual motion processing for first- and second-order stimuli suggests that both early- and later-level neurologic function of the parietal lobe are affected in Fragile X syndrome (FXS). Furthermore, this deficit likely stems from abnormal input from the magnocellular compartment of the lateral geniculate nucleus. Impaired visual form and motion processing for complex visual stimuli with normal processing for simple (i.e., first-order) form stimuli suggests that FXS individuals have normal early form processing accompanied by a generalized impairment in neurologic mechanisms necessary for integrating all early visual input.
Kaneoke, Y; Urakawa, T; Kakigi, R
2009-05-19
We investigated whether direction information is represented in the population-level neural response evoked by the visual motion stimulus, as measured by magnetoencephalography. Coherent motions with varied speed, varied direction, and different coherence level were presented using random dot kinematography. Peak latency of responses to motion onset was inversely related to speed in all directions, as previously reported, but no significant effect of direction on latency changes was identified. Mutual information entropy (IE) calculated using four-direction response data increased significantly (>2.14) after motion onset in 41.3% of response data and maximum IE was distributed at approximately 20 ms after peak response latency. When response waveforms showing significant differences (by multivariate discriminant analysis) in distribution of the three waveform parameters (peak amplitude, peak latency, and 75% waveform width) with stimulus directions were analyzed, 87 waveform stimulus directions (80.6%) were correctly estimated using these parameters. Correct estimation rate was unaffected by stimulus speed, but was affected by coherence level, even though both speed and coherence affected response amplitude similarly. Our results indicate that speed and direction of stimulus motion are represented in the distinct properties of a response waveform, suggesting that the human brain processes speed and direction separately, at least in part.
Kaiser, Alexander; Ismailova, Oksana; Koskela, Antti; Huber, Stefan E.; Ritter, Marcel; Cosenza, Biagio; Benger, Werner; Nazmutdinov, Renat; Probst, Michael
2014-01-01
Molecular dynamics simulations of liquid ethylene glycol described by the OPLS-AA force field were performed to gain insight into its hydrogen-bond structure. We use the population correlation function as a statistical measure for the hydrogen-bond lifetime. In an attempt to understand the complicated hydrogen-bonding, we developed new molecular visualization tools within the Vish Visualization shell and used it to visualize the life of each individual hydrogen-bond. With this tool hydrogen-bond formation and breaking as well as clustering and chain formation in hydrogen-bonded liquids can be observed directly. Liquid ethylene glycol at room temperature does not show significant clustering or chain building. The hydrogen-bonds break often due to the rotational and vibrational motions of the molecules leading to an H-bond half-life time of approximately 1.5 ps. However, most of the H-bonds are reformed again so that after 50 ps only 40% of these H-bonds are irreversibly broken due to diffusional motion. This hydrogen-bond half-life time due to diffusional motion is 80.3 ps. The work was preceded by a careful check of various OPLS-based force fields used in the literature. It was found that they lead to quite different angular and H-bond distributions. PMID:24748697
EFFECTS OF TUMORS ON INHALED PHARMACOLOGIC DRUGS: II. PARTICLE MOTION
ABSTRACT
Computer simulations were conducted to describe drug particle motion in human lung bifurcations with tumors. The computations used FIDAP with a Cray T90 supercomputer. The objective was to better understand particle behavior as affected by particle characteristics...
2013-01-01
Background Cervical dystonia is characterized by involuntary muscle contractions of the neck and abnormal head positions that affect daily life activities and social life of patients. Patients are usually treated with botulinum toxin injections into affected neck muscles to relief pain and improve control of head postures. In addition, many patients are referred for physical therapy to improve their ability to perform activities of daily living. A recent review on allied health interventions in cervical dystonia showed a lack of randomized controlled intervention studies regarding the effectiveness of physical therapy interventions. Methods/design The (cost-) effectiveness of a standardized physical therapy program compared to regular physical therapy, both as add-on treatment to botulinum toxin injections will be determined in a multi-centre, single blinded randomized controlled trial with 100 cervical dystonia patients. Primary outcomes are disability in daily functioning assessed with the disability subscale of the Toronto Western Spasmodic Torticollis Rating Scale. Secondary outcomes are pain, severity of dystonia, active range of motion of the head, quality of life, anxiety and depression. Data will be collected at baseline, after six months and one year by an independent blind assessor just prior to botulinum toxin injections. For the cost effectiveness, an additional economic evaluation will be performed with the costs per quality adjusted life-year as primary outcome parameter. Discussion Our study will provide new evidence regarding the (cost-) effectiveness of a standardized, tailored physical therapy program for patients with cervical dystonia. It is widely felt that allied health interventions, including physical therapy, may offer a valuable supplement to the current therapeutic options. A positive outcome will lead to a greater use of the standardized physical therapy program. For the Dutch situation a positive outcome implies that the standardized physical therapy program forms the basis for a national treatment guideline for cervical dystonia. Trial registration Number Dutch Trial registration (Nederlands Trial Register): NTR3437 PMID:23855591
van den Dool, Joost; Visser, Bart; Koelman, J Hans T M; Engelbert, Raoul H H; Tijssen, Marina A J
2013-07-15
Cervical dystonia is characterized by involuntary muscle contractions of the neck and abnormal head positions that affect daily life activities and social life of patients. Patients are usually treated with botulinum toxin injections into affected neck muscles to relief pain and improve control of head postures. In addition, many patients are referred for physical therapy to improve their ability to perform activities of daily living. A recent review on allied health interventions in cervical dystonia showed a lack of randomized controlled intervention studies regarding the effectiveness of physical therapy interventions. The (cost-) effectiveness of a standardized physical therapy program compared to regular physical therapy, both as add-on treatment to botulinum toxin injections will be determined in a multi-centre, single blinded randomized controlled trial with 100 cervical dystonia patients. Primary outcomes are disability in daily functioning assessed with the disability subscale of the Toronto Western Spasmodic Torticollis Rating Scale. Secondary outcomes are pain, severity of dystonia, active range of motion of the head, quality of life, anxiety and depression. Data will be collected at baseline, after six months and one year by an independent blind assessor just prior to botulinum toxin injections. For the cost effectiveness, an additional economic evaluation will be performed with the costs per quality adjusted life-year as primary outcome parameter. Our study will provide new evidence regarding the (cost-) effectiveness of a standardized, tailored physical therapy program for patients with cervical dystonia. It is widely felt that allied health interventions, including physical therapy, may offer a valuable supplement to the current therapeutic options. A positive outcome will lead to a greater use of the standardized physical therapy program. For the Dutch situation a positive outcome implies that the standardized physical therapy program forms the basis for a national treatment guideline for cervical dystonia. Number Dutch Trial registration (Nederlands Trial Register): NTR3437.
The effect of social interactions in the primary consumption life cycle of motion pictures
NASA Astrophysics Data System (ADS)
Hidalgo R, César A.; Castro, Alejandra; Rodriguez-Sickert, Carlos
2006-04-01
We develop a 'basic principles' model which accounts for the primary life cycle consumption of films as a social coordination problem in which information transmission is governed by word of mouth. We fit the analytical solution of such a model to aggregated consumption data from the film industry and derive a quantitative estimator of its quality based on the structure of the life cycle.
Vestibular signals in primate cortex for self-motion perception.
Gu, Yong
2018-04-21
The vestibular peripheral organs in our inner ears detect transient motion of the head in everyday life. This information is sent to the central nervous system for automatic processes such as vestibulo-ocular reflexes, balance and postural control, and higher cognitive functions including perception of self-motion and spatial orientation. Recent neurophysiological studies have discovered a prominent vestibular network in the primate cerebral cortex. Many of the areas involved are multisensory: their neurons are modulated by both vestibular signals and visual optic flow, potentially facilitating more robust heading estimation through cue integration. Combining psychophysics, computation, physiological recording and causal manipulation techniques, recent work has addressed both the encoding and decoding of vestibular signals for self-motion perception. Copyright © 2018. Published by Elsevier Ltd.
Restoration of motion blurred images
NASA Astrophysics Data System (ADS)
Gaxiola, Leopoldo N.; Juarez-Salazar, Rigoberto; Diaz-Ramirez, Victor H.
2017-08-01
Image restoration is a classic problem in image processing. Image degradations can occur due to several reasons, for instance, imperfections of imaging systems, quantization errors, atmospheric turbulence, relative motion between camera or objects, among others. Motion blur is a typical degradation in dynamic imaging systems. In this work, we present a method to estimate the parameters of linear motion blur degradation from a captured blurred image. The proposed method is based on analyzing the frequency spectrum of a captured image in order to firstly estimate the degradation parameters, and then, to restore the image with a linear filter. The performance of the proposed method is evaluated by processing synthetic and real-life images. The obtained results are characterized in terms of accuracy of image restoration given by an objective criterion.
Image deblurring in smartphone devices using built-in inertial measurement sensors
NASA Astrophysics Data System (ADS)
Šindelář, Ondřej; Šroubek, Filip
2013-01-01
Long-exposure handheld photography is degraded with blur, which is difficult to remove without prior information about the camera motion. In this work, we utilize inertial sensors (accelerometers and gyroscopes) in modern smartphones to detect exact motion trajectory of the smartphone camera during exposure and remove blur from the resulting photography based on the recorded motion data. The whole system is implemented on the Android platform and embedded in the smartphone device, resulting in a close-to-real-time deblurring algorithm. The performance of the proposed system is demonstrated in real-life scenarios.
Hsu, Patty; Taylor, J Eric T; Pratt, Jay
2015-01-01
The Ternus effect is a robust illusion of motion that produces element motion at short interstimulus intervals (ISIs; < 50 ms) and group motion at longer ISIs (> 50 ms). Previous research has shown that the nature of the stimuli (e.g., similarity, grouping), not just ISI, can influence the likelihood of perceiving element or group motion. We examined if semantic knowledge can also influence what type of illusory motion is perceived. In Experiment I, we used a modified Ternus display with pictures of frogs in a jump-ready pose facing forwards or backwards to the direction of illusory motion. Participants perceived more element motion with the forward-facing frogs and more group motion with the backward-facing frogs. Experiment 2 tested whether this effect would still occur with line drawings of frogs, or if a more life-like image was necessary. Experiment 3 tested whether this effect was due to visual asymmetries inherent in the jumping pose. Experiment 4 tested whether frogs in a "non-jumping," sedentary pose would replicate the original effect. These experiments elucidate the role of semantic knowledge in the Ternus effect. Prior knowledge of the movement of certain animate objects, in this case, frogs can also bias the perception of element or group motion.
Application of BCI systems in neurorehabilitation: a scoping review.
Bamdad, Mahdi; Zarshenas, Homayoon; Auais, Mohammad A
2015-01-01
To review various types of electroencephalographic activities of the brain and present an overview of brain-computer interface (BCI) systems' history and their applications in rehabilitation. A scoping review of published English literature on BCI application in the field of rehabilitation was undertaken. IEEE Xplore, ScienceDirect, Google Scholar and Scopus databases were searched since inception up to August 2012. All experimental studies published in English and discussed complete cycle of the BCI process was included in the review. In total, 90 articles met the inclusion criteria and were reviewed. Various approaches that improve the accuracy and performance of BCI systems were discussed. Based on BCI's clinical application, reviewed articles were categorized into three groups: motion rehabilitation, speech rehabilitation and virtual reality control (VRC). Almost half of the reviewed papers (48%) concentrated on VRC. Speech rehabilitation and motion rehabilitation made up 33% and 19% of the reviewed papers, respectively. Among different types of electroencephalography signals, P300, steady state visual evoked potentials and motor imagery signals were the most common. This review discussed various applications of BCI in rehabilitation and showed how BCI can be used to improve the quality of life for people with neurological disabilities. It will develop and promote new models of communication and finally, will create an accurate, reliable, online communication between human brain and computer and reduces the negative effects of external stimuli on BCI performance. Implications for Rehabilitation The field of brain-computer interfaces (BCI) is rapidly advancing and it is expected to fulfill a critical role in rehabilitation of neurological disorders and in movement restoration in the forthcoming years. In the near future, BCI has notable potential to become a major tool used by people with disabilities to control locomotion and communicate with surrounding environment and, consequently, improve the quality of life for many affected persons. Electrical field recording at the scalp (i.e. electroencephalography) is the most likely method to be of practical value for clinical use as it is simple and non-invasive. However, some aspects need future improvements, such as the ability to separate close imagery signal (motion of extremities and phalanges that are close together).
Perceived health from biological motion predicts voting behaviour.
Kramer, Robin S S; Arend, Isabel; Ward, Robert
2010-04-01
Body motion signals socially relevant traits like the sex, age, and even the genetic quality of actors and may therefore facilitate various social judgements. By examining ratings and voting decisions based solely on body motion of political candidates, we considered how the candidates' motion affected people's judgements and voting behaviour. In two experiments, participants viewed stick figure motion displays made from videos of politicians in public debate. Participants rated the motion displays for a variety of social traits and then indicated their vote preference. In both experiments, perceived physical health was the single best predictor of vote choice, and no two-factor model produced significant improvement. Notably, although attractiveness and leadership correlated with voting behaviour, neither provided additional explanatory power to a single-factor model of health alone. Our results demonstrate for the first time that motion can produce systematic vote preferences.
Mobile user identity sensing using the motion sensor
NASA Astrophysics Data System (ADS)
Zhao, Xi; Feng, Tao; Xu, Lei; Shi, Weidong
2014-05-01
Employing mobile sensor data to recognize user behavioral activities has been well studied in recent years. However, to adopt the data as a biometric modality has rarely been explored. Existing methods either used the data to recognize gait, which is considered as a distinguished identity feature; or segmented a specific kind of motion for user recognition, such as phone picking-up motion. Since the identity and the motion gesture jointly affect motion data, to fix the gesture (walking or phone picking-up) definitively simplifies the identity sensing problem. However, it meanwhile introduces the complexity from gesture detection or requirement on a higher sample rate from motion sensor readings, which may draw the battery fast and affect the usability of the phone. In general, it is still under investigation that motion based user authentication in a large scale satisfies the accuracy requirement as a stand-alone biometrics modality. In this paper, we propose a novel approach to use the motion sensor readings for user identity sensing. Instead of decoupling the user identity from a gesture, we reasonably assume users have their own distinguishing phone usage habits and extract the identity from fuzzy activity patterns, represented by a combination of body movements whose signals in chains span in relative low frequency spectrum and hand movements whose signals span in relative high frequency spectrum. Then Bayesian Rules are applied to analyze the dependency of different frequency components in the signals. During testing, a posterior probability of user identity given the observed chains can be computed for authentication. Tested on an accelerometer dataset with 347 users, our approach has demonstrated the promising results.
Medical aspects of ambulance design.
Snook, R
1972-09-02
Various observations have shown that the interior layout of many ambulances leaves much to be desired. The lighting levels are inadequate, heat loss could be prevented, vehicle identification and passage through traffic could be improved, and measurable differences exist between the ride characteristics of commercially available ambulances, a prototype purpose-built ambulance, and a private car. Moreover the condition of some patients may be affected by the motion of the vehicle either directly or indirectly. Even though they form a small percentage of the total number carried, they represent a very considerable financial risk. A personally conducted survey of ambulance chief officers showed a deep interest and involvement in the upgrading of the service with a general dissatisfaction with many of the vehicles currently available. Hence there is a market for the purpose-built ambulance, which would benefit the patient and the ambulanceman alike.The inadequacies of many vehicles currently in use as ambulances have been shown to work against the interests of the patient requiring life support treatment, and it is suggested that this warrants urgent attention and action. A more extensive research project involving medical observations on the supine sick and injured, attendant task performance, and instrumentation analysis of linear and angular vehicle motions should enable the harmful effects of ride motion to be identified.None of these investigations, however, will be of any value unless they are used in developing future ambulances. Such development must also parallel an increase in the awareness of the importance of ambulance design and its relation to the increased comfort and chance of survival of the patients carried.
Medical Aspects of Ambulance Design
Snook, Roger
1972-01-01
Various observations have shown that the interior layout of many ambulances leaves much to be desired. The lighting levels are inadequate, heat loss could be prevented, vehicle identification and passage through traffic could be improved, and measurable differences exist between the ride characteristics of commercially available ambulances, a prototype purpose-built ambulance, and a private car. Moreover the condition of some patients may be affected by the motion of the vehicle either directly or indirectly. Even though they form a small percentage of the total number carried, they represent a very considerable financial risk. A personally conducted survey of ambulance chief officers showed a deep interest and involvement in the upgrading of the service with a general dissatisfaction with many of the vehicles currently available. Hence there is a market for the purpose-built ambulance, which would benefit the patient and the ambulanceman alike. The inadequacies of many vehicles currently in use as ambulances have been shown to work against the interests of the patient requiring life support treatment, and it is suggested that this warrants urgent attention and action. A more extensive research project involving medical observations on the supine sick and injured, attendant task performance, and instrumentation analysis of linear and angular vehicle motions should enable the harmful effects of ride motion to be identified. None of these investigations, however, will be of any value unless they are used in developing future ambulances. Such development must also parallel an increase in the awareness of the importance of ambulance design and its relation to the increased comfort and chance of survival of the patients carried. ImagesFIG. 2FIG. 4 PMID:5069643
Unukovych, Dmytro; Johansson, Hemming; Johansson, Elizabeth; Arver, Brita; Liljegren, Annelie; Brandberg, Yvonne
2014-08-01
The rate of prophylactic mastectomies (PM) is increasing. Patients generally report high levels of health related quality of life and satisfaction after the procedure, whereas body image perception and sexuality may be negatively affected. The aim of the study was to evaluate the interest in physical therapy as a means of improving body image and sexuality in women after PM. Patients undergoing PM at Karolinska University Hospital between 2006 and 2010 were eligible. The following patient-reported outcome measures were used at study baseline and 2 years postoperatively: the body image scale (BIS), the sexual activity questionnaire (SAQ), the short-form health survey (SF-36), the hospital anxiety and depression scale (HAD), and a study specific "pain/motion/sensation scale". Out of 125 patients invited to participate in this prospective randomized study, 43 (34%) consented and were randomized into the intervention (n = 24, 56%) or control (n = 19, 44%) groups. There were no statistically significant between-group differences found with respect to BIS, SAQ, SF-36, HAD, and "pain/motion/sensation". Two years postoperatively, more than half of the patients in both groups reported problems like feeling less attractive, less sexually attractive, their body feeling less whole, and being dissatisfied with their body. A majority marked a decreased sensation in breast area. The interest in a physiotherapy intervention was limited among women who had undergone PM. The intervention did not show any substantial effects. A large proportion of patients reported specific body image related and pain/motion/sensation problems postoperatively. Copyright © 2014 Elsevier Ltd. All rights reserved.
Project Physics Reader 2, Motion in the Heavens.
ERIC Educational Resources Information Center
Harvard Univ., Cambridge, MA. Harvard Project Physics.
As a supplement to Project Physics Unit 2, specially selected articles are presented in this reader for student browsing. Eight excerpts are given under headings: the starry messenger, Newton and the principia, an appreciation of the earth, space the unconquerable, "Is there intelligent life beyond the earth?," the life story of a…
ERIC Educational Resources Information Center
Journal of College Science Teaching, 2005
2005-01-01
A recent study by Zara Ambadar and Jeffrey F. Cohn of the University of Pittsburgh and Jonathan W. Schooler of the University of British Columbia, examined how motion affects people's judgment of subtle facial expressions. Two experiments demonstrated robust effects of motion in facilitating the perception of subtle facial expressions depicting…
Slow motion increases perceived intent
Caruso, Eugene M.; Burns, Zachary C.; Converse, Benjamin A.
2016-01-01
To determine the appropriate punishment for a harmful action, people must often make inferences about the transgressor’s intent. In courtrooms and popular media, such inferences increasingly rely on video evidence, which is often played in “slow motion.” Four experiments (n = 1,610) involving real surveillance footage from a murder or broadcast replays of violent contact in professional football demonstrate that viewing an action in slow motion, compared with regular speed, can cause viewers to perceive an action as more intentional. This slow motion intentionality bias occurred, in part, because slow motion video caused participants to feel like the actor had more time to act, even when they knew how much clock time had actually elapsed. Four additional experiments (n = 2,737) reveal that allowing viewers to see both regular speed and slow motion replay mitigates the bias, but does not eliminate it. We conclude that an empirical understanding of the effect of slow motion on mental state attribution should inform the life-or-death decisions that are currently based on tacit assumptions about the objectivity of human perception. PMID:27482091
NASA Technical Reports Server (NTRS)
Reschke, M. F.; Parker, D. E.; Arrott, A. P.
1986-01-01
Report discusses physiological and physical concepts of proposed training system to precondition astronauts to weightless environment. System prevents motion sickness, often experienced during early part of orbital flight. Also helps prevent seasickness and other forms of terrestrial motion sickness, often experienced during early part of orbital flight. Training affects subject's perception of inner-ear signals, visual signals, and kinesthetic motion perception. Changed perception resembles that of astronauts who spent many days in space and adapted to weightlessness.
The Reproduction of Scientific Understanding about Pendulum Motion in the Public
NASA Astrophysics Data System (ADS)
Manabu, Sumida
This paper describes life-span development of understanding about pendulum motion and effects of school science. The subjects were 2,766 people ranging from kindergartners up to 88 years senior citizens. The conflict and consensus between children and their parent's understanding of pendulum motion were also analyzed. The kindergartner's understanding, mostly non-scientific, made a marked developmental change to another type of non-scientific understanding by the time they reach G 4. Parents with scientific understanding do not presumably nurture scientifically minded children,even though about half of them can apply scientific conceptions that shorter pendulums swing faster, and the amplitude and speed of pendulum motion do not depend on its weight. There seems to be another type of developmental change from scientific understanding to non-scientific understanding around their fifties. Itis suggested that the scientific understanding in the public about pendulum motion become predominant due to the educational intervention through school science.
Autogenic-Feedback Training for the Control of Space Motion Sickness
NASA Technical Reports Server (NTRS)
Cowings, Patricia S.; Toscano, W. B.
1994-01-01
This paper presents case-studies of 9 shuttle crewmembers (prime and alternates) and one U.S. Navy F-18 pilot, as they participated in all preflight training and testing activities in support of a life sciences flight experiment aboard Spacelab-J, and Spacelab-3. The primary objective of the flight experiment was to determine if Autogenic-feedback training (AFT), a physiological self-regulation training technique would be an effective treatment for motion sickness and space motion sickness in these crewmembers. Additional objectives of this study involved the examining human physiological responses to motion sickness on Earth and in space, as well as developing predictive criteria for susceptibility to space motion sickness based on ground-based data. Comparisons of these crewmembers are made to a larger set of subjects from previous experiments (treatment and "test-only" controls subjects). This paper describes all preflight methods, results and proposed changes for future tests.
Effects of Autonomic Conditioning on Motion Sickness Tolerance
NASA Technical Reports Server (NTRS)
Cowings, P. S.; Toscano, W. B.
1994-01-01
This paper presents case-studies of 9 shuttle crewmembers (prime and alternates) and one U.S. Navy F-18 pilot, as they participated in all preflight training and testing activities in support of a life sciences flight experiment aboard Spacelab-J, and Spacelab-3. The primary objective of the flight experiment was to determine if Autogenic-feedback training (AFT), a physiological self-regulation training technique would be an effective treatment for motion sickness and space motion sickness in these crewmembers. Additional objectives of this study involved the examining human Physiological- responses to motion sickness on Earth and in space, as well as developing predictive criteria for susceptibility to space motion sickness based on ground-based data. Comparisons of these crewmembers are made to a larger set of subjects from previous experiments (treatment and test-only controls subjects). This paper describes all preflight methods, results and proposed changes for future tests.
An ordination of life histories using morphological proxies: capital vs. income breeding in insects.
Davis, Robert B; Javoiš, Juhan; Kaasik, Ants; Õunap, Erki; Tammaru, Toomas
2016-08-01
Predictive classifications of life histories are essential for evolutionary ecology. While attempts to apply a single approach to all organisms may be overambitious, recent advances suggest that more narrow ordination schemes can be useful. However, these schemes mostly lack easily observable proxies of the position of a species on respective axes. It has been proposed that, in insects, the degree of capital (vs. income) breeding, reflecting the importance of adult feeding for reproduction, correlates with various ecological traits at the level of among-species comparison. We sought to prove these ideas via rigorous phylogenetic comparative analyses. We used experimentally derived life-history data for 57 species of European Geometridae (Lepidoptera), and an original phylogenetic reconstruction. The degree of capital breeding was estimated based on morphological proxies, including relative abdomen size of females. Applying Brownian-motion-based comparative analyses (with an original update to include error estimates), we demonstrated the associations between the degree of capital breeding and larval diet breadth, sexual size dimorphism, and reproductive season. Ornstein-Uhlenbeck model based phylogenetic analysis suggested a causal relationship between the degree of capital breeding and diet breadth. Our study indicates that the gradation from capital to income breeding is an informative axis to ordinate life-history strategies in flying insects which are affected by the fecundity vs. mobility trade off, with the availability of easy to record proxies contributing to its predictive power in practical contexts. © 2016 by the Ecological Society of America.
Liquid rocket actuators and operators. [in spacecraft control systems
NASA Technical Reports Server (NTRS)
1973-01-01
All the types of actuators and associated operators used in booster, upper stage, and spacecraft propulsion and reaction-control systems except for chemical-explosive actuators and turbine actuators are discussed. Discussion of static and dynamic seals, mechanical transmission of motion, and instrumentation is included to the extent that actuator or operator design is affected. Selection of the optimum actuator configuration is discussed for specific application which require a tradeoff study that considers all the relevant factors: available energy sources, load capacity, stroke, speed of response, leakage limitations, environmental conditions, chemical compatibility, storage life and conditions, size, weight, and cost. These factors are interrelated with overall control-system design evaluations that are beyond the scope of this monograph; however, literature references are cited for a detailed review of the general considerations. Perinent advanced-state-of-the-art design concepts are surveyed briefly.
Ghasemzadeh, Hassan; Loseu, Vitali; Jafari, Roozbeh
2010-03-01
Mobile sensor-based systems are emerging as promising platforms for healthcare monitoring. An important goal of these systems is to extract physiological information about the subject wearing the network. Such information can be used for life logging, quality of life measures, fall detection, extraction of contextual information, and many other applications. Data collected by these sensor nodes are overwhelming, and hence, an efficient data processing technique is essential. In this paper, we present a system using inexpensive, off-the-shelf inertial sensor nodes that constructs motion transcripts from biomedical signals and identifies movements by taking collaboration between the nodes into consideration. Transcripts are built of motion primitives and aim to reduce the complexity of the original data. We then label each primitive with a unique symbol and generate a sequence of symbols, known as motion template, representing a particular action. This model leads to a distributed algorithm for action recognition using edit distance with respect to motion templates. The algorithm reduces the number of active nodes during every classification decision. We present our results using data collected from five normal subjects performing transitional movements. The results clearly illustrate the effectiveness of our framework. In particular, we obtain a classification accuracy of 84.13% with only one sensor node involved in the classification process.
Hoffman, David M.; Karasev, Vasiliy I.; Banks, Martin S.
2011-01-01
Most stereoscopic displays rely on field-sequential presentation to present different images to the left and right eyes. With sequential presentation, images are delivered to each eye in alternation with dark intervals, and each eye receives its images in counter phase with the other eye. This type of presentation can exacerbate image artifacts including flicker, and the appearance of unsmooth motion. To address the flicker problem, some methods repeat images multiple times before updating to new ones. This greatly reduces flicker visibility, but makes motion appear less smooth. This paper describes an investigation of how different presentation methods affect the visibility of flicker, motion artifacts, and distortions in perceived depth. It begins with an examination of these methods in the spatio-temporal frequency domain. From this examination, it describes a series of predictions for how presentation rate, object speed, simultaneity of image delivery to the two eyes, and other properties ought to affect flicker, motion artifacts, and depth distortions, and reports a series of experiments that tested these predictions. The results confirmed essentially all of the predictions. The paper concludes with a summary and series of recommendations for the best approach to minimize these undesirable effects. PMID:21572544
A theoretical analysis of airplane longitudinal stability and control as affected by wind shear
NASA Technical Reports Server (NTRS)
Sherman, W. L.
1977-01-01
The longitudinal equations of motion with wind shear terms were used to analyze the stability and motions of a jet transport. A positive wind shear gives a decreasing head wind or changes a head wind into a tail wind. A negative wind shear gives a decreasing tail wind or changes a tail wind into a head wind. It was found that wind shear had very little effect on the short period mode and that negative wind shear, although it affected the phugoid, did not cause stability problems. On the other hand, it was found that positive wind shear can cause the phugoid to become aperiodic and unstable. In this case, a stability boundary for the phugoid was found that is valid for most aircraft at all flight speeds. Calculations of aircraft motions confirmed the results of the stability analysis. It was found that a flight path control automatic pilot and an airspeed control system provide good control in all types of wind shear. Appendixes give equations of motion that include the effects of downdrafts and updrafts and extend the longitudinal equations of motion for shear to six degrees of freedom.
Motion transparency: making models of motion perception transparent.
Snowden; Verstraten
1999-10-01
In daily life our visual system is bombarded with motion information. We see cars driving by, flocks of birds flying in the sky, clouds passing behind trees that are dancing in the wind. Vision science has a good understanding of the first stage of visual motion processing, that is, the mechanism underlying the detection of local motions. Currently, research is focused on the processes that occur beyond the first stage. At this level, local motions have to be integrated to form objects, define the boundaries between them, construct surfaces and so on. An interesting, if complicated case is known as motion transparency: the situation in which two overlapping surfaces move transparently over each other. In that case two motions have to be assigned to the same retinal location. Several researchers have tried to solve this problem from a computational point of view, using physiological and psychophysical results as a guideline. We will discuss two models: one uses the traditional idea known as 'filter selection' and the other a relatively new approach based on Bayesian inference. Predictions from these models are compared with our own visual behaviour and that of the neural substrates that are presumed to underlie these perceptions.
Fluid models and simulations of biological cell phenomena
NASA Technical Reports Server (NTRS)
Greenspan, H. P.
1982-01-01
The dynamics of coated droplets are examined within the context of biofluids. Of specific interest is the manner in which the shape of a droplet, the motion within it as well as that of aggregates of droplets can be controlled by the modulation of surface properties and the extent to which such fluid phenomena are an intrinsic part of cellular processes. From the standpoint of biology, an objective is to elucidate some of the general dynamical features that affect the disposition of an entire cell, cell colonies and tissues. Conventionally averaged field variables of continuum mechanics are used to describe the overall global effects which result from the myriad of small scale molecular interactions. An attempt is made to establish cause and effect relationships from correct dynamical laws of motion rather than by what may have been unnecessary invocation of metabolic or life processes. Several topics are discussed where there are strong analogies droplets and cells including: encapsulated droplets/cell membranes; droplet shape/cell shape; adhesion and spread of a droplet/cell motility and adhesion; and oams and multiphase flows/cell aggregates and tissues. Evidence is presented to show that certain concepts of continuum theory such as suface tension, surface free energy, contact angle, bending moments, etc. are relevant and applicable to the study of cell biology.
Khedr, Maan; El-Sheimy, Nasser
2017-01-01
The growing market of smart devices make them appealing for various applications. Motion tracking can be achieved using such devices, and is important for various applications such as navigation, search and rescue, health monitoring, and quality of life-style assessment. Step detection is a crucial task that affects the accuracy and quality of such applications. In this paper, a new step detection technique is proposed, which can be used for step counting and activity monitoring for health applications as well as part of a Pedestrian Dead Reckoning (PDR) system. Inertial and Magnetic sensors measurements are analyzed and fused for detecting steps under varying step modes and device pose combinations using a free-moving handheld device (smartphone). Unlike most of the state of the art research in the field, the proposed technique does not require a classifier, and adaptively tunes the filters and thresholds used without the need for presets while accomplishing the task in a real-time operation manner. Testing shows that the proposed technique successfully detects steps under varying motion speeds and device use cases with an average performance of 99.6%, and outperforms some of the state of the art techniques that rely on classifiers and commercial wristband products. PMID:29117143
Long period nodal motion of sun synchronous orbits
NASA Technical Reports Server (NTRS)
Duck, K. I.
1975-01-01
An approximative model is formulated for assessing these perturbations that significantly affect long term modal motion of sun synchronous orbits. Computer simulations with several independent computer programs consider zonal and tesseral gravitational harmonics, third body gravitational disturbances induced by the sun and the moon, and atmospheric drag. A pendulum model consisting of evenzonal harmonics through order 4 and solar gravity dominated nodal motion approximation. This pendulum motion results from solar gravity inducing an inclination oscillation which couples into the nodal precession induced by the earth's oblateness. The pendulum model correlated well with simulations observed flight data.
Improvement in gait following combined ankle and subtalar arthrodesis.
Tenenbaum, Shay; Coleman, Scott C; Brodsky, James W
2014-11-19
This study assessed the hypothesis that arthrodesis of both the ankle and the hindfoot joints produces an objective improvement of function as measured by gait analysis of patients with severe ankle and hindfoot arthritis. Twenty-one patients with severe ankle and hindfoot arthritis who underwent unilateral tibiotalocalcaneal arthrodesis with an intramedullary nail were prospectively studied with three-dimensional (3D) gait analysis at a minimum of one year postoperatively. The mean age at the time of the operation was fifty-nine years, and the mean duration of follow-up was seventeen months (range, twelve to thirty-one months). Temporospatial measurements included cadence, step length, walking velocity, and total support time. The kinematic parameters were sagittal plane motion of the ankle, knee, and hip. The kinetic parameters were sagittal plane ankle power and moment and hip power. Symmetry of gait was analyzed by comparing the step lengths on the affected and unaffected sides. There was significant improvement in multiple parameters of postoperative gait as compared with the patients' own preoperative function. Temporospatial data showed significant increases in cadence (p = 0.03) and walking speed (p = 0.001) and decreased total support time (p = 0.02). Kinematic results showed that sagittal plane ankle motion had decreased, from 13.2° preoperatively to 10.2° postoperatively, in the operatively treated limb (p = 0.02), and increased from 22.2° to 24.1° (p = 0.01) in the contralateral limb. Hip motion on the affected side increased from 39° to 43° (p = 0.007), and knee motion increased from 56° to 60° (p = 0.054). Kinetic results showed significant increases in ankle moment (p < 0.0001) of the operatively treated limb, ankle power of the contralateral limb (p = 0.009), and hip power on the affected side (p = 0.005) postoperatively. There was a significant improvement in gait symmetry (p = 0.01). There was a small loss of sagittal plane motion in the affected limb postoperatively. There were marked increases in gait velocity, ankle moment, and hip motion and power, documenting objective improvements in ambulatory function. The data showed that preoperative ankle motion was greatly diminished. This may suggest that pain is more important than stiffness in asymmetric gait. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
Interactions between motion and form processing in the human visual system.
Mather, George; Pavan, Andrea; Bellacosa Marotti, Rosilari; Campana, Gianluca; Casco, Clara
2013-01-01
The predominant view of motion and form processing in the human visual system assumes that these two attributes are handled by separate and independent modules. Motion processing involves filtering by direction-selective sensors, followed by integration to solve the aperture problem. Form processing involves filtering by orientation-selective and size-selective receptive fields, followed by integration to encode object shape. It has long been known that motion signals can influence form processing in the well-known Gestalt principle of common fate; texture elements which share a common motion property are grouped into a single contour or texture region. However, recent research in psychophysics and neuroscience indicates that the influence of form signals on motion processing is more extensive than previously thought. First, the salience and apparent direction of moving lines depends on how the local orientation and direction of motion combine to match the receptive field properties of motion-selective neurons. Second, orientation signals generated by "motion-streaks" influence motion processing; motion sensitivity, apparent direction and adaptation are affected by simultaneously present orientation signals. Third, form signals generated by human body shape influence biological motion processing, as revealed by studies using point-light motion stimuli. Thus, form-motion integration seems to occur at several different levels of cortical processing, from V1 to STS.
Interactions between motion and form processing in the human visual system
Mather, George; Pavan, Andrea; Bellacosa Marotti, Rosilari; Campana, Gianluca; Casco, Clara
2013-01-01
The predominant view of motion and form processing in the human visual system assumes that these two attributes are handled by separate and independent modules. Motion processing involves filtering by direction-selective sensors, followed by integration to solve the aperture problem. Form processing involves filtering by orientation-selective and size-selective receptive fields, followed by integration to encode object shape. It has long been known that motion signals can influence form processing in the well-known Gestalt principle of common fate; texture elements which share a common motion property are grouped into a single contour or texture region. However, recent research in psychophysics and neuroscience indicates that the influence of form signals on motion processing is more extensive than previously thought. First, the salience and apparent direction of moving lines depends on how the local orientation and direction of motion combine to match the receptive field properties of motion-selective neurons. Second, orientation signals generated by “motion-streaks” influence motion processing; motion sensitivity, apparent direction and adaptation are affected by simultaneously present orientation signals. Third, form signals generated by human body shape influence biological motion processing, as revealed by studies using point-light motion stimuli. Thus, form-motion integration seems to occur at several different levels of cortical processing, from V1 to STS. PMID:23730286
Prevalence, Predictors, and Prevention of Motion Sickness in Zero-G Parabolic Flights.
Golding, John F; Paillard, Aurore C; Normand, Hervé; Besnard, Stéphane; Denise, Pierre
2017-01-01
Zero-G parabolic flight reproduces the weightlessness of space for short periods. However, motion sickness may affect some fliers. The aim was to assess the extent of this problem and to find possible predictors and modifying factors. Airbus zero-G flights consist of 31 parabolas performed in blocks. Each parabola consisted of 20 s of 0 g sandwiched by 20 s of hypergravity of 1.5-1.8 g. The survey covered N = 246 person-flights (193 men, 53 women), ages (M ± SD) 36.0 ± 11.3 yr. An anonymous questionnaire included motion sickness rating (1 = OK to 6 = vomiting), Motion Sickness Susceptibility Questionnaire (MSSQ), antimotion sickness medication, prior zero-G experience, anxiety level, and other characteristics. Participants had lower MSSQ percentile scores (27.4 ± 28.0) than the population norm of 50. Motion sickness was experienced by 33% and 12% vomited. Less motion sickness was predicted by older age, greater prior zero-G flight experience, medication with scopolamine, lower MSSQ scores, but not gender or anxiety. Sickness ratings in fliers pretreated with scopolamine (1.81 ± 1.58) were lower than for nonmedicated fliers (2.93 ± 2.16), and incidence of vomiting in fliers using scopolamine treatment was reduced by half to a third. Possible confounding factors including age, sex, flight experience, and MSSQ could not account for this. Motion sickness affected one-third of zero-G fliers despite being intrinsically less motion sickness susceptible compared to the general population. Susceptible individuals probably try to avoid such a provocative environment. Risk factors for motion sickness included younger age and higher MSSQ scores. Protective factors included prior zero-G flight experience (habituation) and antimotion sickness medication.Golding JF, Paillard AC, Normand H, Besnard S, Denise P. Prevalence, predictors, and prevention of motion sickness in zero-G parabolic flights. Aerosp Med Hum Perform. 2017; 88(1):3-9.
Kinetics of the Shanghai Maglev: Kinematical Analysis of a Real "Textbook" Case of Linear Motion
NASA Astrophysics Data System (ADS)
Hsu, Tung
2014-10-01
A vehicle starts from rest at constant acceleration, then cruises at constant speed for a time. Next, it decelerates at a constant rate.… This and similar statements are common in elementary physics courses. Students are asked to graph the motion of the vehicle or find the velocity, acceleration, and distance traveled by the vehicle from a given graph.1 However, a "constant acceleration-constant velocity-constant deceleration" motion, which gives us an ideal trapezoidal shape in the velocity-time graph, is not common in everyday life. Driving a car or riding a bicycle for a short distance can be much more complicated. Therefore, it is interesting to take a look at a real case of "constant acceleration-constant velocity-constant deceleration" motion.
Assessing Motion Induced Interruptions Using a Motion Platform
2013-09-01
same way that cars have shock absorbers to decrease jolt from potholes and bumps in the road, ships may have the potential to be designed to better...Integration (HSI) seeks to assure human performance to reduce operating costs. This thesis seeks to develop a model for ship design in relation to Motion...Induced Interruptions (MII). The model is based on the premise that MIIs affect specific domains of HSI in an adverse way. Future ship design
Matsumoto, Yukiko; Takahashi, Hideyuki; Murai, Toshiya; Takahashi, Hidehiko
2015-01-01
Schizophrenia patients have impairments at several levels of cognition including visual attention (eye movements), perception, and social cognition. However, it remains unclear how lower-level cognitive deficits influence higher-level cognition. To elucidate the hierarchical path linking deficient cognitions, we focused on biological motion perception, which is involved in both the early stage of visual perception (attention) and higher social cognition, and is impaired in schizophrenia. Seventeen schizophrenia patients and 18 healthy controls participated in the study. Using point-light walker stimuli, we examined eye movements during biological motion perception in schizophrenia. We assessed relationships among eye movements, biological motion perception and empathy. In the biological motion detection task, schizophrenia patients showed lower accuracy and fixated longer than healthy controls. As opposed to controls, patients exhibiting longer fixation durations and fewer numbers of fixations demonstrated higher accuracy. Additionally, in the patient group, the correlations between accuracy and affective empathy index and between eye movement index and affective empathy index were significant. The altered gaze patterns in patients indicate that top-down attention compensates for impaired bottom-up attention. Furthermore, aberrant eye movements might lead to deficits in biological motion perception and finally link to social cognitive impairments. The current findings merit further investigation for understanding the mechanism of social cognitive training and its development. Copyright © 2014 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.
Backhausen, Lea L.; Herting, Megan M.; Buse, Judith; Roessner, Veit; Smolka, Michael N.; Vetter, Nora C.
2016-01-01
In structural magnetic resonance imaging motion artifacts are common, especially when not scanning healthy young adults. It has been shown that motion affects the analysis with automated image-processing techniques (e.g., FreeSurfer). This can bias results. Several developmental and adult studies have found reduced volume and thickness of gray matter due to motion artifacts. Thus, quality control is necessary in order to ensure an acceptable level of quality and to define exclusion criteria of images (i.e., determine participants with most severe artifacts). However, information about the quality control workflow and image exclusion procedure is largely lacking in the current literature and the existing rating systems differ. Here, we propose a stringent workflow of quality control steps during and after acquisition of T1-weighted images, which enables researchers dealing with populations that are typically affected by motion artifacts to enhance data quality and maximize sample sizes. As an underlying aim we established a thorough quality control rating system for T1-weighted images and applied it to the analysis of developmental clinical data using the automated processing pipeline FreeSurfer. This hands-on workflow and quality control rating system will aid researchers in minimizing motion artifacts in the final data set, and therefore enhance the quality of structural magnetic resonance imaging studies. PMID:27999528
How Do Changes in Speed Affect the Perception of Duration?
ERIC Educational Resources Information Center
Matthews, William J.
2011-01-01
Six experiments investigated how changes in stimulus speed influence subjective duration. Participants saw rotating or translating shapes in three conditions: constant speed, accelerating motion, and decelerating motion. The distance moved and average speed were the same in all three conditions. In temporal judgment tasks, the constant-speed…
Cross-cultural aging in cognitive and affective components of subjective well-being.
Pethtel, Olivia; Chen, Yiwei
2010-09-01
The present study examined age and cultural differences in cognitive and affective components of subjective well-being. A sample of 188 American and Chinese young and older adults completed surveys measuring self-life satisfaction, perceived family's life satisfaction, positive affect, and negative affect. Across cultures, older adults reported lower negative affect than did young adults. Americans reported higher self-life satisfaction, perceived family's life satisfaction, and positive affect than did Chinese. In addition, perceived family's life satisfaction was more related to self-life satisfaction for Chinese than for Americans. Findings are discussed in light of socioemotional selectivity theory and theories on culture and self-construal. (c) 2010 APA, all rights reserved.
with greater range of motion and active power, will translate into improved functional performance, ambulatory safety (risk of falls) and quality of... life in trans-tibial amputees (TTA) who function as limited community ambulators. We will assess these outcomes in 54 veterans with TTA by randomizing
Kong, Dali; Lin, Wei; Pan, Yongxin; Zhang, Keke
2014-01-01
We investigate the swimming motion of rod-shaped magnetotactic bacteria affiliated with the Nitrospirae phylum in a viscous liquid under the influence of an externally imposed, time-dependent magnetic field. By assuming that fluid motion driven by the translation and rotation of a swimming bacterium is of the Stokes type and that inertial effects of the motion are negligible, we derive a new system of the twelve coupled equations that govern both the motion and orientation of a swimming rod-shaped magnetotactic bacterium with a growing magnetic moment in the laboratory frame of reference. It is revealed that the initial pattern of swimming motion can be strongly affected by the rate of the growing magnetic moment. It is also revealed, through comparing mathematical solutions of the twelve coupled equations to the swimming motion observed in our laboratory experiments with rod-shaped magnetotactic bacteria, that the laboratory trajectories of the swimming motion can be approximately reproduced using an appropriate set of the parameters in our theoretical model. PMID:24523716
Collective Motion in Bacterial Populations with Mixed Phenotypic Behaviors
NASA Astrophysics Data System (ADS)
Hoeger, Kentaro; Strickland, Ben; Shoup, Daniel; Ursell, Tristan
The motion of large, densely packed groups of organisms is often qualitatively distinct from the motion of individuals, yet hinges on individual properties and behaviors. Collective motion of bacteria depends strongly on the phenotypic behaviors of individual cells, the physical interactions between cells, and the geometry of their environment, often with multiple phenotypes coexisting in a population. Thus, to characterize how these selectively important interactions affect group traits, such as cell dispersal, spatial segregation of phenotypes, and material transport in groups, we use a library of Bacillus subtilis mutants that modulate chemotaxis, motility, and biofilm formation. By mixing phenotypes and observing bacterial behaviors and motion at single cell resolution, we probe collective motion as a function of phenotypic mixture and environmental geometry. Our work demonstrates that collective microbial motion exhibits a transition, from `turbulence' to semiballistic burrowing, as phenotypic composition varies. This work illuminates the role that individual cell behaviors play in the emergence of collective motion, and may signal qualitatively distinct regimes of material transport in bacterial populations. University of Oregon.
Embodied affectivity: on moving and being moved
Fuchs, Thomas; Koch, Sabine C.
2014-01-01
There is a growing body of research indicating that bodily sensation and behavior strongly influences one's emotional reaction toward certain situations or objects. On this background, a framework model of embodied affectivity1 is suggested: we regard emotions as resulting from the circular interaction between affective qualities or affordances in the environment and the subject's bodily resonance, be it in the form of sensations, postures, expressive movements or movement tendencies. Motion and emotion are thus intrinsically connected: one is moved by movement (perception; impression; affection2) and moved to move (action; expression; e-motion). Through its resonance, the body functions as a medium of emotional perception: it colors or charges self-experience and the environment with affective valences while it remains itself in the background of one's own awareness. This model is then applied to emotional social understanding or interaffectivity which is regarded as an intertwinement of two cycles of embodied affectivity, thus continuously modifying each partner's affective affordances and bodily resonance. We conclude with considerations of how embodied affectivity is altered in psychopathology and can be addressed in psychotherapy of the embodied self. PMID:24936191
Raabe, D; Harrison, A; Ireland, A; Alemzadeh, K; Sandy, J; Dogramadzi, S; Melhuish, C; Burgess, S
2012-03-01
This paper presents a new in vitro wear simulator based on spatial parallel kinematics and a biologically inspired implicit force/position hybrid controller to replicate chewing movements and dental wear formations on dental components, such as crowns, bridges or a full set of teeth. The human mandible, guided by passive structures such as posterior teeth and the two temporomandibular joints, moves with up to 6 degrees of freedom (DOF) in Cartesian space. The currently available wear simulators lack the ability to perform these chewing movements. In many cases, their lack of sufficient DOF enables them only to replicate the sliding motion of a single occlusal contact point by neglecting rotational movements and the motion along one Cartesian axis. The motion and forces of more than one occlusal contact points cannot accurately be replicated by these instruments. Furthermore, the majority of wear simulators are unable to control simultaneously the main wear-affecting parameters, considering abrasive mechanical wear, which are the occlusal sliding motion and bite forces in the constraint contact phase of the human chewing cycle. It has been shown that such discrepancies between the true in vivo and the simulated in vitro condition influence the outcome and the quality of wear studies. This can be improved by implementing biological features of the human masticatory system such as tooth compliance realized through the passive action of the periodontal ligament and active bite force control realized though the central nervous system using feedback from periodontal preceptors. The simulator described in this paper can be used for single- and multi-occlusal contact testing due to its kinematics and ability to exactly replicate human translational and rotational mandibular movements with up to 6 DOF without neglecting movements along or around the three Cartesian axes. Recorded human mandibular motion and occlusal force data are the reference inputs of the simulator. Experimental studies of wear using this simulator demonstrate that integrating the biological feature of combined force/position hybrid control in dental material testing improves the linearity and reduces the variability of results. In addition, it has been shown that present biaxially operated dental wear simulators are likely to provide misleading results in comparative in vitro/in vivo one-contact studies due to neglecting the occlusal sliding motion in one plane which could introduce an error of up to 49% since occlusal sliding motion D and volumetric wear loss V(loss) are proportional.
Simulation of ground motion using the stochastic method
Boore, D.M.
2003-01-01
A simple and powerful method for simulating ground motions is to combine parametric or functional descriptions of the ground motion's amplitude spectrum with a random phase spectrum modified such that the motion is distributed over a duration related to the earthquake magnitude and to the distance from the source. This method of simulating ground motions often goes by the name "the stochastic method." It is particularly useful for simulating the higher-frequency ground motions of most interest to engineers (generally, f>0.1 Hz), and it is widely used to predict ground motions for regions of the world in which recordings of motion from potentially damaging earthquakes are not available. This simple method has been successful in matching a variety of ground-motion measures for earthquakes with seismic moments spanning more than 12 orders of magnitude and in diverse tectonic environments. One of the essential characteristics of the method is that it distills what is known about the various factors affecting ground motions (source, path, and site) into simple functional forms. This provides a means by which the results of the rigorous studies reported in other papers in this volume can be incorporated into practical predictions of ground motion.
Life expectancy of modular Ti6Al4V hip implants: influence of stress and environment.
Chandra, A; Ryu, J J; Karra, P; Shrotriya, P; Tvergaard, V; Gaisser, M; Weik, T
2011-11-01
Stress dependent electrochemical dissolution is identified as one of the key mechanisms governing surface degradation in fretting and crevice corrosion of biomedical implants. The present study focuses on delineating the roles of mechanical stress and chemical conditions on the life expectancy of modular hip implants. First, material removal on a stressed surface of Ti6Al4V subjected to single asperity contact is investigated experimentally to identify the influence of contact load, in-plane stress and chemical environment on mean wear rates. A range of known stress levels are applied to the specimen while its surface is mechanically stimulated in different non-reactive to oxidizing aqueous environments. Evolution of surface degradation is monitored, and its mechanism is elucidated. This phase allows estimation of Preston Constant which is later used in the analysis. Second phase of the work is semi-analytical and computational, where, based on the estimated Preston constant and other material and process parameters, the scratch propensity (consisting of magnitude of scratch depth and their frequency per unit area) due to micro-motion in modular hip implants is estimated. The third phase views these scratches as initial notches and utilizes a mixed-mode fatigue crack propagation model to estimate the critical crack length for onset of instability. The number of loading cycles needed to reach this critical crack length is then labeled as the expected life of the implant under given mechanical and chemical conditions. Implications of different material and process conditions to life expectancy of orthopedic implants are discussed. It is observed that transverse micro-motion, compared to longitudinal micro-motion, plays a far more critical role in determining the implant life. Patient body weight, as well as proximity of the joint fluid to its iso-electric point play key roles in determining wear rates and associated life expectancies of modular hip implants. Sustained aeration of joint fluid, as well as proper tolerancing of mating surfaces, along with a proper choice of material microstructure may be utilized to extend implant life. Copyright © 2011 Elsevier Ltd. All rights reserved.
Motion processing with two eyes in three dimensions.
Rokers, Bas; Czuba, Thaddeus B; Cormack, Lawrence K; Huk, Alexander C
2011-02-11
The movement of an object toward or away from the head is perhaps the most critical piece of information an organism can extract from its environment. Such 3D motion produces horizontally opposite motions on the two retinae. Little is known about how or where the visual system combines these two retinal motion signals, relative to the wealth of knowledge about the neural hierarchies involved in 2D motion processing and binocular vision. Canonical conceptions of primate visual processing assert that neurons early in the visual system combine monocular inputs into a single cyclopean stream (lacking eye-of-origin information) and extract 1D ("component") motions; later stages then extract 2D pattern motion from the cyclopean output of the earlier stage. Here, however, we show that 3D motion perception is in fact affected by the comparison of opposite 2D pattern motions between the two eyes. Three-dimensional motion sensitivity depends systematically on pattern motion direction when dichoptically viewing gratings and plaids-and a novel "dichoptic pseudoplaid" stimulus provides strong support for use of interocular pattern motion differences by precluding potential contributions from conventional disparity-based mechanisms. These results imply the existence of eye-of-origin information in later stages of motion processing and therefore motivate the incorporation of such eye-specific pattern-motion signals in models of motion processing and binocular integration.
Analysis of Motorcycle Weave Mode by using Energy Flow Method
NASA Astrophysics Data System (ADS)
Marumo, Yoshitaka; Katayama, Tsuyoshi
The activation mechanism of motorcycle weave mode is clarified within the framework of the energy flow method, which calculates energy flow of mechanical forces in each motion. It is demonstrated that only a few mechanical forces affect the stability of the weave mode from among a total of about 40 mechanical forces. The activation of the lateral, yawing and rolling motions destabilize the weave mode, while activation of the steering motion stabilizes the weave mode. A detailed investigation of the energy flow of the steering motion reveals that the steering motion plays an important role in clarifying the characteristics of the weave mode. As activation of the steering motion progresses the phase of the front tire side force, and the weave mode is consequently stabilized. This paper provides a design guide for stabilizing the weave mode and the wobble mode compatibility.
Flight Simulator Platform Motion and Air Transport Pilot Training
NASA Technical Reports Server (NTRS)
Lee, Alfred T.; Bussolari, Steven R.
1989-01-01
The influence of flight simulator platform motion on pilot training and performance was examined In two studies utilizing a B-727-200 aircraft simulator. The simulator, located at Ames Research Center, Is certified by the FAA for upgrade and transition training in air carrier operations. Subjective ratings and objective performance of experienced B-727 pilots did not reveal any reliable effects of wide variations In platform motion de- sign. Motion platform variations did, however, affect the acquisition of control skill by pilots with no prior heavy aircraft flying experience. The effect was limited to pitch attitude control inputs during the early phase of landing training. Implications for the definition of platform motion requirements in air transport pilot training are discussed.
Strong motion deficits in dyslexia associated with DCDC2 gene alteration.
Cicchini, Guido Marco; Marino, Cecilia; Mascheretti, Sara; Perani, Daniela; Morrone, Maria Concetta
2015-05-27
Dyslexia is a specific impairment in reading that affects 1 in 10 people. Previous studies have failed to isolate a single cause of the disorder, but several candidate genes have been reported. We measured motion perception in two groups of dyslexics, with and without a deletion within the DCDC2 gene, a risk gene for dyslexia. We found impairment for motion particularly strong at high spatial frequencies in the population carrying the deletion. The data suggest that deficits in motion processing occur in a specific genotype, rather than the entire dyslexia population, contributing to the large variability in impairment of motion thresholds in dyslexia reported in the literature. Copyright © 2015 the authors 0270-6474/15/358059-06$15.00/0.
Symeonidou, Evangelia-Regkina; Nordin, Andrew D; Hairston, W David; Ferris, Daniel P
2018-04-03
More neuroscience researchers are using scalp electroencephalography (EEG) to measure electrocortical dynamics during human locomotion and other types of movement. Motion artifacts corrupt the EEG and mask underlying neural signals of interest. The cause of motion artifacts in EEG is often attributed to electrode motion relative to the skin, but few studies have examined EEG signals under head motion. In the current study, we tested how motion artifacts are affected by the overall mass and surface area of commercially available electrodes, as well as how cable sway contributes to motion artifacts. To provide a ground-truth signal, we used a gelatin head phantom with embedded antennas broadcasting electrical signals, and recorded EEG with a commercially available electrode system. A robotic platform moved the phantom head through sinusoidal displacements at different frequencies (0-2 Hz). Results showed that a larger electrode surface area can have a small but significant effect on improving EEG signal quality during motion and that cable sway is a major contributor to motion artifacts. These results have implications in the development of future hardware for mobile brain imaging with EEG.
Forward and backward motion of artificial helical swimmers in cylindrical channels
NASA Astrophysics Data System (ADS)
Acemoglu, Alperen; Temel, Fatma Zeynep; Yesilyurt, Serhat
2013-11-01
Motion of micro swimmers in confined geometries such as channels is important due to its relevance in in vivo medical applications such as minimally invasive surgery and drug delivery. Here, swimmers with diameters 0.8 mm and lengths 2 to 3 mm are produced with a 3D printer and cylindrical Nd2Fe14B magnets are placed inside the bodies. Rotating external magnetic field is used for the actuation of artificial swimmers. Different body and tail geometries are produced and experiments are conducted with a glycerol filled circular channel. Result demonstrate that decreasing channel diameter directly affects the forward motion of the swimmer due to the increasing drag. It is observed that step-out frequency, which defines maximum frequency at which the swimmer can establish a synchronous rotation with the external magnetic field, depends on the geometry of the swimmer and the channel diameter. There are significant differences between low and high frequency motion and forward and backward swimming. Longer tails enable higher forward velocities in high frequencies than backward ones, whereas forward and backward velocities are approximately the same at low frequencies. Furthermore backward motion is more stable than the forward one; at high frequencies, swimmers travel almost at the center of the channel for backward motion, and follow a helical trajectory near the wall during the forward motion. According to simulation results there is a flow which is induced by the rotation of the swimmer rotation that affects the swimmer's trajectory. We acknowledge the support from TUBITAK (Techonological & Research Council of Turkey) under the grant no: 111M376.
Goal-directed action is automatically biased towards looming motion
Moher, Jeff; Sit, Jonathan; Song, Joo-Hyun
2014-01-01
It is known that looming motion can capture attention regardless of an observer’s intentions. Real-world behavior, however, frequently involves not just attentional selection, but selection for action. Thus, it is important to understand the impact of looming motion on goal-directed action to gain a broader perspective on how stimulus properties bias human behavior. We presented participants with a visually-guided reaching task in which they pointed to a target letter presented among non-target distractors. On some trials, one of the pre-masks at the location of the upcoming search objects grew rapidly in size, creating the appearance of a “looming” target or distractor. Even though looming motion did not predict the target location, the time required to reach to the target was shorter when the target loomed compared to when a distractor loomed. Furthermore, reach movement trajectories were pulled towards the location of a looming distractor when one was present, a pull that was greater still when the looming motion was on a collision path with the participant. We also contrast reaching data with data from a similarly designed visual search task requiring keypress responses. This comparison underscores the sensitivity of visually-guided reaching data, as some experimental manipulations, such as looming motion path, affected reach trajectories but not keypress measures. Together, the results demonstrate that looming motion biases visually-guided action regardless of an observer’s current behavioral goals, affecting not only the time required to reach to targets but also the path of the observer’s hand movement itself. PMID:25159287
Using Nonlinearity and Contact Lines to Control Fluid Flow in Microgravity
NASA Technical Reports Server (NTRS)
Perlin, M.; Schultz, W. W.; Bian, X.; Agarwal, M.
2002-01-01
Slug flows in a tube are affected by surface tension and contact lines, especially under microgravity. Numerical analyses and experiments are conducted of slug flows in small-diameter tubes with horizontal, inclined and vertical orientations. A PID-controlled, meter-long platform capable of following specified motions is used. An improved understanding of the contact line boundary condition for steady and unsteady contact-line motion is expected. Lastly, a direct fluid-handling method using nonlinear oscillatory motion of a tube is presented.
Flight simulator platform motion and air transport pilot training
NASA Technical Reports Server (NTRS)
Lee, Alfred T.; Bussolari, Steven R.
1987-01-01
The effect of a flight simulator platform motion on the performance and training of a pilot was evaluated using subjective ratings and objective performance data obtained on experienced B-727 pilots and pilots with no prior heavy aircraft flying experience flying B-727-200 aircraft simulator used by the FAA in the upgrade and transition training for air carrier operations. The results on experienced pilots did not reveal any reliable effects of wide variations in platform motion design. On the other hand, motion variations significantly affected the behavior of pilots without heavy-aircraft experience. The effect was limited to pitch attitude control inputs during the early phase of landing training.
Effect of micro-stirring on enzymatic reaction kinetics inside a biomimetic container
NASA Astrophysics Data System (ADS)
Gozen, Irep; Horowitz, Viva; Chambers, Zachary; Manoharan, Vinothan
The intracellular environment is dynamic, influenced by the motion of active machinery such as cytoskeleton filaments and molecular motors. To understand whether and how such activity affects the rates of diffusion-limited reactions, we construct a model system consisting of a phospholipid vesicle encapsulating a small number of micro- or nanoparticles, the active motion of which can be induced by chemical or magnetic cues. We aim to determine a relation between active motion of particles and rates of enzymatic reactions in the confined volume. Our findings might illuminate how active motion influences cytoplasmic reaction dynamics, or may have played a role in protocell genetics.
Altered sensory-motor control of the head as an etiological factor in space-motion sickness
NASA Technical Reports Server (NTRS)
Lackner, J. R.; DiZio, P.
1989-01-01
Mechanical unloading during head movements in weightlessness may be an etiological factor in space-motion sickness. We simulated altered head loading on Earth without affecting vestibular stimulation by having subjects wear a weighted helmet. Eight subjects were exposed to constant velocity rotation about a vertical axis with direction reversals every 60 sec. for eight reversals with the head loaded and eight with the head unloaded. The severity of motion sickness elicited was significantly higher when the head was loaded. This suggests that altered sensory-motor control of the head is also an etiological factor in space-motion sickness.
ERIC Educational Resources Information Center
Darling, Gerald
2012-01-01
Whether playing soccer at recess, walking to lunch, or sitting at their desk, children encounter forces every moment of their lives. The connection between force and motion is absolutely amazing to children, so anyone working with them better be prepared for the battery of tough questions they ask: "What made the ball move that way? Why does a…
Use of cues in virtual reality depends on visual feedback.
Fulvio, Jacqueline M; Rokers, Bas
2017-11-22
3D motion perception is of central importance to daily life. However, when tested in laboratory settings, sensitivity to 3D motion signals is found to be poor, leading to the view that heuristics and prior assumptions are critical for 3D motion perception. Here we explore an alternative: sensitivity to 3D motion signals is context-dependent and must be learned based on explicit visual feedback in novel environments. The need for action-contingent visual feedback is well-established in the developmental literature. For example, young kittens that are passively moved through an environment, but unable to move through it themselves, fail to develop accurate depth perception. We find that these principles also obtain in adult human perception. Observers that do not experience visual consequences of their actions fail to develop accurate 3D motion perception in a virtual reality environment, even after prolonged exposure. By contrast, observers that experience the consequences of their actions improve performance based on available sensory cues to 3D motion. Specifically, we find that observers learn to exploit the small motion parallax cues provided by head jitter. Our findings advance understanding of human 3D motion processing and form a foundation for future study of perception in virtual and natural 3D environments.
Helton, Kristen L; Ratner, Buddy D; Wisniewski, Natalie A
2011-01-01
This article is the second part of a two-part review in which we explore the biomechanics of the sensor–tissue interface as an important aspect of continuous glucose sensor biocompatibility. Part I, featured in this issue of Journal of Diabetes Science and Technology, describes a theoretical framework of how biomechanical factors such as motion and pressure (typically micromotion and micropressure) affect tissue physiology around a sensor and in turn, impact sensor performance. Here in Part II, a literature review is presented that summarizes examples of motion or pressure affecting sensor performance. Data are presented that show how both acute and chronic forces can impact continuous glucose monitor signals. Also presented are potential strategies for countering the ill effects of motion and pressure on glucose sensors. Improved engineering and optimized chemical biocompatibility have advanced sensor design and function, but we believe that mechanical biocompatibility, a rarely considered factor, must also be optimized in order to achieve an accurate, long-term, implantable sensor. PMID:21722579
NASA Astrophysics Data System (ADS)
Kulkarni, Sandip; Ramaswamy, Bharath; Horton, Emily; Gangapuram, Sruthi; Nacev, Alek; Depireux, Didier; Shimoji, Mika; Shapiro, Benjamin
2015-11-01
This article presents a method to investigate how magnetic particle characteristics affect their motion inside tissues under the influence of an applied magnetic field. Particles are placed on top of freshly excised tissue samples, a calibrated magnetic field is applied by a magnet underneath each tissue sample, and we image and quantify particle penetration depth by quantitative metrics to assess how particle sizes, their surface coatings, and tissue resistance affect particle motion. Using this method, we tested available fluorescent particles from Chemicell of four sizes (100 nm, 300 nm, 500 nm, and 1 μm diameter) with four different coatings (starch, chitosan, lipid, and PEG/P) and quantified their motion through freshly excised rat liver, kidney, and brain tissues. In broad terms, we found that the applied magnetic field moved chitosan particles most effectively through all three tissue types (as compared to starch, lipid, and PEG/P coated particles). However, the relationship between particle properties and their resulting motion was found to be complex. Hence, it will likely require substantial further study to elucidate the nuances of transport mechanisms and to select and engineer optimal particle properties to enable the most effective transport through various tissue types under applied magnetic fields.
The Role of Large-Scale Motions in Catalysis by Dihydrofolate Reductase
2011-01-01
Dihydrofolate reductase has long been used as a model system to study the coupling of protein motions to enzymatic hydride transfer. By studying environmental effects on hydride transfer in dihydrofolate reductase (DHFR) from the cold-adapted bacterium Moritella profunda (MpDHFR) and comparing the flexibility of this enzyme to that of DHFR from Escherichia coli (EcDHFR), we demonstrate that factors that affect large-scale (i.e., long-range, but not necessarily large amplitude) protein motions have no effect on the kinetic isotope effect on hydride transfer or its temperature dependence, although the rates of the catalyzed reaction are affected. Hydrogen/deuterium exchange studies by NMR-spectroscopy show that MpDHFR is a more flexible enzyme than EcDHFR. NMR experiments with EcDHFR in the presence of cosolvents suggest differences in the conformational ensemble of the enzyme. The fact that enzymes from different environmental niches and with different flexibilities display the same behavior of the kinetic isotope effect on hydride transfer strongly suggests that, while protein motions are important to generate the reaction ready conformation, an optimal conformation with the correct electrostatics and geometry for the reaction to occur, they do not influence the nature of the chemical step itself; large-scale motions do not couple directly to hydride transfer proper in DHFR. PMID:22060818
Holistic processing of static and moving faces.
Zhao, Mintao; Bülthoff, Isabelle
2017-07-01
Humans' face ability develops and matures with extensive experience in perceiving, recognizing, and interacting with faces that move most of the time. However, how facial movements affect 1 core aspect of face ability-holistic face processing-remains unclear. Here we investigated the influence of rigid facial motion on holistic and part-based face processing by manipulating the presence of facial motion during study and at test in a composite face task. The results showed that rigidly moving faces were processed as holistically as static faces (Experiment 1). Holistic processing of moving faces persisted whether facial motion was presented during study, at test, or both (Experiment 2). Moreover, when faces were inverted to eliminate the contributions of both an upright face template and observers' expertise with upright faces, rigid facial motion facilitated holistic face processing (Experiment 3). Thus, holistic processing represents a general principle of face perception that applies to both static and dynamic faces, rather than being limited to static faces. These results support an emerging view that both perceiver-based and face-based factors contribute to holistic face processing, and they offer new insights on what underlies holistic face processing, how information supporting holistic face processing interacts with each other, and why facial motion may affect face recognition and holistic face processing differently. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Research and technology activities at Ames Research Center's Biomedical Research Division
NASA Technical Reports Server (NTRS)
Martello, N.
1985-01-01
Various research and technology activities at Ames Research Center's Biomedical Research Division are described. Contributions to the Space Administration's goals in the life sciences include descriptions of research in operational medicine, cardiovascular deconditioning, motion sickness, bone alterations, muscle atrophy, fluid and electrolyte changes, radiation effects and protection, behavior and performance, gravitational biology, and life sciences flight experiments.
A novel approach to simulate chest wall micro-motion for bio-radar life detection purpose
NASA Astrophysics Data System (ADS)
An, Qiang; Li, Zhao; Liang, Fulai; Chen, Fuming; Wang, Jianqi
2016-10-01
Volunteers are often recruited to serve as the detection targets during the research process of bio-radar life detection technology, in which the experiment results are highly susceptible to the physical status of different individuals (shape, posture, etc.). In order to objectively evaluate the radar system performance and life detection algorithms, a standard detection target is urgently needed. The paper first proposed a parameter quantitatively controllable system to simulate the chest wall micro-motion caused mainly by breathing and heart beating. Then, the paper continued to analyze the material and size selection of the scattering body mounted on the simulation system from the perspective of back scattering energy. The computational electromagnetic method was employed to determine the exact scattering body. Finally, on-site experiments were carried out to verify the reliability of the simulation platform utilizing an IR UWB bioradar. Experimental result shows that the proposed system can simulate a real human target from three aspects: respiration frequency, amplitude and body surface scattering energy. Thus, it can be utilized as a substitute for a human target in radar based non-contact life detection research in various scenarios.
A longitudinal analysis of chronic arm morbidity following breast cancer surgery.
Boquiren, Virginia M; Hack, Thomas F; Thomas, Roanne L; Towers, Anna; Kwan, Winkle B; Tilley, Andrea; Quinlan, Elizabeth; Miedema, Baukje
2016-06-01
Arm morbidity (AM) arising from breast cancer (BC) treatment can detrimentally impact quality of life; often limiting a survivor's ability to participate in valued activities. The present study explored (a) the developmental time course of AM [restricted range of motion (ROM), pain, and arm volume changes], negative affect, and perceived disability in the immediate years post-surgery, and (b) the mediating role of perceived disability on the relationship between AM and negative affect over time. In this 5-year longitudinal study, BC survivors from four Canadian oncology clinics (n = 431) completed five annual clinical assessments, where differences in ROM (shoulder abduction, external rotation) and arm volume between the affected and non-affected arm were measured. The profile of mood states (POMS), disability of arm, shoulder, hand, and McGill Pain Questionnaire-Short form were completed. Results from general linear modeling showed that AM, negative affect, and perceived disability were greatest 1-year post-surgery, declined, and with the exception of arm volume changes, were significantly lower 5 years later. Negative affect was significantly associated with restrictions in shoulder abduction and external rotation (average r = -0.15; p < 0.05) and present arm pain (average r = 0.28, p < 0.01) at most assessments. The mediating role of perceived disability on the relationship between AM and negative affect was statistically significant in a majority of assessments. Perceived disability is the underlying factor driving the relationship between AM and mood disturbance over time. Rehabilitative therapy to improve survivors' functional well-being might mitigate the negative impacts of AM on emotional health.
Strategies to minimize sedation in pediatric body magnetic resonance imaging.
Jaimes, Camilo; Gee, Michael S
2016-05-01
The high soft-tissue contrast of MRI and the absence of ionizing radiation make it a valuable tool for assessment of body pathology in children. Infants and young children are often unable to cooperate with awake MRI so sedation or general anesthesia might be required. However, given recent data on the costs and potential risks of anesthesia in young children, there is a need to try to decrease or avoid sedation in this population when possible. Child life specialists in radiology frequently use behavioral techniques and audiovisual support devices, and they practice with children and families using mock scanners to improve child compliance with MRI. Optimization of the MR scanner environment is also important to create a child-friendly space. If the child can remain inside the MRI scanner, a variety of emerging techniques can reduce the effect of involuntary motion. Using sequences with short acquisition times such as single-shot fast spin echo and volumetric gradient echo can decrease artifacts and improve image quality. Breath-holding, respiratory triggering and signal averaging all reduce respiratory motion. Emerging techniques such as radial and multislice k-space acquisition, navigator motion correction, as well as parallel imaging and compressed sensing reconstruction methods can further accelerate acquisition and decrease motion. Collaboration among radiologists, anesthesiologists, technologists, child life specialists and families is crucial for successful performance of MRI in young children.
Robust real-time extraction of respiratory signals from PET list-mode data.
Salomon, Andre; Zhang, Bin; Olivier, Patrick; Goedicke, Andreas
2018-05-01
Respiratory motion, which typically cannot simply be suspended during PET image acquisition, affects lesions' detection and quantitative accuracy inside or in close vicinity to the lungs. Some motion compensation techniques address this issue via pre-sorting ("binning") of the acquired PET data into a set of temporal gates, where each gate is assumed to be minimally affected by respiratory motion. Tracking respiratory motion is typically realized using dedicated hardware (e.g. using respiratory belts and digital cameras). Extracting respiratory signalsdirectly from the acquired PET data simplifies the clinical workflow as it avoids to handle additional signal measurement equipment. We introduce a new data-driven method "Combined Local Motion Detection" (CLMD). It uses the Time-of-Flight (TOF) information provided by state-of-the-art PET scanners in order to enable real-time respiratory signal extraction without additional hardware resources. CLMD applies center-of-mass detection in overlapping regions based on simple back-positioned TOF event sets acquired in short time frames. Following a signal filtering and quality-based pre-selection step, the remaining extracted individual position information over time is then combined to generate a global respiratory signal. The method is evaluated using 7 measured FDG studies from single and multiple scan positions of the thorax region, and it is compared to other software-based methods regarding quantitative accuracy and statistical noise stability. Correlation coefficients around 90% between the reference and the extracted signal have been found for those PET scans where motion affected features such as tumors or hot regions were present in the PET field-of-view. For PET scans with a quarter of typically applied radiotracer doses, the CLMD method still provides similar high correlation coefficients which indicates its robustness to noise. Each CLMD processing needed less than 0.4s in total on a standard multi-core CPU and thus provides a robust and accurate approach enabling real-time processing capabilities using standard PC hardware. © 2018 Institute of Physics and Engineering in Medicine.
Robust real-time extraction of respiratory signals from PET list-mode data
NASA Astrophysics Data System (ADS)
Salomon, André; Zhang, Bin; Olivier, Patrick; Goedicke, Andreas
2018-06-01
Respiratory motion, which typically cannot simply be suspended during PET image acquisition, affects lesions’ detection and quantitative accuracy inside or in close vicinity to the lungs. Some motion compensation techniques address this issue via pre-sorting (‘binning’) of the acquired PET data into a set of temporal gates, where each gate is assumed to be minimally affected by respiratory motion. Tracking respiratory motion is typically realized using dedicated hardware (e.g. using respiratory belts and digital cameras). Extracting respiratory signals directly from the acquired PET data simplifies the clinical workflow as it avoids handling additional signal measurement equipment. We introduce a new data-driven method ‘combined local motion detection’ (CLMD). It uses the time-of-flight (TOF) information provided by state-of-the-art PET scanners in order to enable real-time respiratory signal extraction without additional hardware resources. CLMD applies center-of-mass detection in overlapping regions based on simple back-positioned TOF event sets acquired in short time frames. Following a signal filtering and quality-based pre-selection step, the remaining extracted individual position information over time is then combined to generate a global respiratory signal. The method is evaluated using seven measured FDG studies from single and multiple scan positions of the thorax region, and it is compared to other software-based methods regarding quantitative accuracy and statistical noise stability. Correlation coefficients around 90% between the reference and the extracted signal have been found for those PET scans where motion affected features such as tumors or hot regions were present in the PET field-of-view. For PET scans with a quarter of typically applied radiotracer doses, the CLMD method still provides similar high correlation coefficients which indicates its robustness to noise. Each CLMD processing needed less than 0.4 s in total on a standard multi-core CPU and thus provides a robust and accurate approach enabling real-time processing capabilities using standard PC hardware.
Roughness Effects on Fretting Fatigue
NASA Astrophysics Data System (ADS)
Yue, Tongyan; Abdel Wahab, Magd
2017-05-01
Fretting is a small oscillatory relative motion between two normal loaded contact surfaces. It may cause fretting fatigue, fretting wear and/or fretting corrosion damage depending on various fretting couples and working conditions. Fretting fatigue usually occurs at partial slip condition, and results in catastrophic failure at the stress levels below the fatigue limit of the material. Many parameters may affect fretting behaviour, including the applied normal load and displacement, material properties, roughness of the contact surfaces, frequency, etc. Since fretting damage is undesirable due to contacting, the effect of rough contact surfaces on fretting damage has been studied by many researchers. Experimental method on this topic is usually focusing on rough surface effects by finishing treatment and random rough surface effects in order to increase fretting fatigue life. However, most of numerical models on roughness are based on random surface. This paper reviewed both experimental and numerical methodology on the rough surface effects on fretting fatigue.
An error-based micro-sensor capture system for real-time motion estimation
NASA Astrophysics Data System (ADS)
Yang, Lin; Ye, Shiwei; Wang, Zhibo; Huang, Zhipei; Wu, Jiankang; Kong, Yongmei; Zhang, Li
2017-10-01
A wearable micro-sensor motion capture system with 16 IMUs and an error-compensatory complementary filter algorithm for real-time motion estimation has been developed to acquire accurate 3D orientation and displacement in real life activities. In the proposed filter algorithm, the gyroscope bias error, orientation error and magnetic disturbance error are estimated and compensated, significantly reducing the orientation estimation error due to sensor noise and drift. Displacement estimation, especially for activities such as jumping, has been the challenge in micro-sensor motion capture. An adaptive gait phase detection algorithm has been developed to accommodate accurate displacement estimation in different types of activities. The performance of this system is benchmarked with respect to the results of VICON optical capture system. The experimental results have demonstrated effectiveness of the system in daily activities tracking, with estimation error 0.16 ± 0.06 m for normal walking and 0.13 ± 0.11 m for jumping motions. Research supported by the National Natural Science Foundation of China (Nos. 61431017, 81272166).
Human Age Estimation Method Robust to Camera Sensor and/or Face Movement
Nguyen, Dat Tien; Cho, So Ra; Pham, Tuyen Danh; Park, Kang Ryoung
2015-01-01
Human age can be employed in many useful real-life applications, such as customer service systems, automatic vending machines, entertainment, etc. In order to obtain age information, image-based age estimation systems have been developed using information from the human face. However, limitations exist for current age estimation systems because of the various factors of camera motion and optical blurring, facial expressions, gender, etc. Motion blurring can usually be presented on face images by the movement of the camera sensor and/or the movement of the face during image acquisition. Therefore, the facial feature in captured images can be transformed according to the amount of motion, which causes performance degradation of age estimation systems. In this paper, the problem caused by motion blurring is addressed and its solution is proposed in order to make age estimation systems robust to the effects of motion blurring. Experiment results show that our method is more efficient for enhancing age estimation performance compared with systems that do not employ our method. PMID:26334282
The Verriest Lecture: Color lessons from space, time, and motion
Shevell, Steven K.
2012-01-01
The appearance of a chromatic stimulus depends on more than the wavelengths composing it. The scientific literature has countless examples showing that spatial and temporal features of light influence the colors we see. Studying chromatic stimuli that vary over space, time or direction of motion has a further benefit beyond predicting color appearance: the unveiling of otherwise concealed neural processes of color vision. Spatial or temporal stimulus variation uncovers multiple mechanisms of brightness and color perception at distinct levels of the visual pathway. Spatial variation in chromaticity and luminance can change perceived three-dimensional shape, an example of chromatic signals that affect a percept other than color. Chromatic objects in motion expose the surprisingly weak link between the chromaticity of objects and their physical direction of motion, and the role of color in inducing an illusory motion direction. Space, time and motion – color’s colleagues – reveal the richness of chromatic neural processing. PMID:22330398
Defining the computational structure of the motion detector in Drosophila
Clark, Damon A.; Bursztyn, Limor; Horowitz, Mark; Schnitzer, Mark J.; Clandinin, Thomas R.
2011-01-01
SUMMARY Many animals rely on visual motion detection for survival. Motion information is extracted from spatiotemporal intensity patterns on the retina, a paradigmatic neural computation. A phenomenological model, the Hassenstein-Reichardt Correlator (HRC), relates visual inputs to neural and behavioral responses to motion, but the circuits that implement this computation remain unknown. Using cell-type specific genetic silencing, minimal motion stimuli, and in vivo calcium imaging, we examine two critical HRC inputs. These two pathways respond preferentially to light and dark moving edges. We demonstrate that these pathways perform overlapping but complementary subsets of the computations underlying the HRC. A numerical model implementing differential weighting of these operations displays the observed edge preferences. Intriguingly, these pathways are distinguished by their sensitivities to a stimulus correlation that corresponds to an illusory percept, “reverse phi”, that affects many species. Thus, this computational architecture may be widely used to achieve edge selectivity in motion detection. PMID:21689602
Flies and humans share a motion estimation strategy that exploits natural scene statistics
Clark, Damon A.; Fitzgerald, James E.; Ales, Justin M.; Gohl, Daryl M.; Silies, Marion A.; Norcia, Anthony M.; Clandinin, Thomas R.
2014-01-01
Sighted animals extract motion information from visual scenes by processing spatiotemporal patterns of light falling on the retina. The dominant models for motion estimation exploit intensity correlations only between pairs of points in space and time. Moving natural scenes, however, contain more complex correlations. Here we show that fly and human visual systems encode the combined direction and contrast polarity of moving edges using triple correlations that enhance motion estimation in natural environments. Both species extract triple correlations with neural substrates tuned for light or dark edges, and sensitivity to specific triple correlations is retained even as light and dark edge motion signals are combined. Thus, both species separately process light and dark image contrasts to capture motion signatures that can improve estimation accuracy. This striking convergence argues that statistical structures in natural scenes have profoundly affected visual processing, driving a common computational strategy over 500 million years of evolution. PMID:24390225
Motion and gravity effects in the precision of quantum clocks.
Lindkvist, Joel; Sabín, Carlos; Johansson, Göran; Fuentes, Ivette
2015-05-19
We show that motion and gravity affect the precision of quantum clocks. We consider a localised quantum field as a fundamental model of a quantum clock moving in spacetime and show that its state is modified due to changes in acceleration. By computing the quantum Fisher information we determine how relativistic motion modifies the ultimate bound in the precision of the measurement of time. While in the absence of motion the squeezed vacuum is the ideal state for time estimation, we find that it is highly sensitive to the motion-induced degradation of the quantum Fisher information. We show that coherent states are generally more resilient to this degradation and that in the case of very low initial number of photons, the optimal precision can be even increased by motion. These results can be tested with current technology by using superconducting resonators with tunable boundary conditions.
Picosecond molecular motions in bacteriorhodopsin from neutron scattering.
Fitter, J; Lechner, R E; Dencher, N A
1997-01-01
The characteristics of internal molecular motions of bacteriorhodopsin in the purple membrane have been studied by quasielastic incoherent neutron scattering. Because of the quasihomogeneous distribution of hydrogen atoms in biological molecules, this technique enables one to study a wide variety of intramolecular motions, especially those occurring in the picosecond to nanosecond time scale. We performed measurements at different energy resolutions with samples at various hydration levels within a temperature range of 10-300 K. The analysis of the data revealed a dynamical transition at temperatures Td between 180 K and 220 K for all motions resolved at time scales ranging from 0.1 to a few hundred picoseconds. Whereas below Td the motions are purely vibrational, they are predominantly diffusive above Td, characterized by an enormously broad distribution of correlation times. The variation of the hydration level, on the other hand, mainly affects motions slower than a few picoseconds. PMID:9336208
Motion and gravity effects in the precision of quantum clocks
Lindkvist, Joel; Sabín, Carlos; Johansson, Göran; Fuentes, Ivette
2015-01-01
We show that motion and gravity affect the precision of quantum clocks. We consider a localised quantum field as a fundamental model of a quantum clock moving in spacetime and show that its state is modified due to changes in acceleration. By computing the quantum Fisher information we determine how relativistic motion modifies the ultimate bound in the precision of the measurement of time. While in the absence of motion the squeezed vacuum is the ideal state for time estimation, we find that it is highly sensitive to the motion-induced degradation of the quantum Fisher information. We show that coherent states are generally more resilient to this degradation and that in the case of very low initial number of photons, the optimal precision can be even increased by motion. These results can be tested with current technology by using superconducting resonators with tunable boundary conditions. PMID:25988238
Guilt leads to enhanced facing-the-viewer bias
Shen, Mowei; Zhu, Chengfeng; Liao, Huayu; Zhang, Haihang; Zhou, Jifan
2018-01-01
As an important moral emotion, guilt plays a critical role in social interaction. It has been found that people tended to exhibit prosocial behavior under circumstances of guilt. However, all extant studies have predominantly focused on the influence of guilt on macro-level behavior. So far, no study has investigated whether guilt affects people’s micro-level perception. The current study closes this gap by examining whether guilt affects one’s inclination to perceive approaching motion. We achieved this aim by probing a facing-the-viewer bias (FTV bias). Specifically, when an ambiguous walking biological motion display is presented to participants via the point-light display technique, participants tend to perceive a walking agent approaching them. We hypothesized that guilt modulated FTV bias. To test this hypothesis, we adopted a two-person situation induction task to induce guilt, whereby participants were induced to feel that because of their poor task performance, their partner did not receive a satisfactory payment. We found that when participants were told that the perceived biological motion was motion-captured from their partner, the FTV bias was significantly increased for guilty participants relative to neutral participants. However, when participants were informed that the perceived biological motion was from a third neutral agent, the FTV bias was not modulated by guilt. These results suggest that guilt influences one’s inclination to perceive approaching motion, but this effect is constrained to the person towards whom guilt is directed. PMID:29649338
Cognitive Rehabilitation in Bilateral Vestibular Patients: A Computational Perspective.
Ellis, Andrew W; Schöne, Corina G; Vibert, Dominique; Caversaccio, Marco D; Mast, Fred W
2018-01-01
There is evidence that vestibular sensory processing affects, and is affected by, higher cognitive processes. This is highly relevant from a clinical perspective, where there is evidence for cognitive impairments in patients with peripheral vestibular deficits. The vestibular system performs complex probabilistic computations, and we claim that understanding these is important for investigating interactions between vestibular processing and cognition. Furthermore, this will aid our understanding of patients' self-motion perception and will provide useful information for clinical interventions. We propose that cognitive training is a promising way to alleviate the debilitating symptoms of patients with complete bilateral vestibular loss (BVP), who often fail to show improvement when relying solely on conventional treatment methods. We present a probabilistic model capable of processing vestibular sensory data during both passive and active self-motion. Crucially, in our model, knowledge from multiple sources, including higher-level cognition, can be used to predict head motion. This is the entry point for cognitive interventions. Despite the loss of sensory input, the processing circuitry in BVP patients is still intact, and they can still perceive self-motion when the movement is self-generated. We provide computer simulations illustrating self-motion perception of BVP patients. Cognitive training may lead to more accurate and confident predictions, which result in decreased weighting of sensory input, and thus improved self-motion perception. Using our model, we show the possible impact of cognitive interventions to help vestibular rehabilitation in patients with BVP.
Effects of Crowding and Attention on High-Levels of Motion Processing and Motion Adaptation
Pavan, Andrea; Greenlee, Mark W.
2015-01-01
The motion after-effect (MAE) persists in crowding conditions, i.e., when the adaptation direction cannot be reliably perceived. The MAE originating from complex moving patterns spreads into non-adapted sectors of a multi-sector adapting display (i.e., phantom MAE). In the present study we used global rotating patterns to measure the strength of the conventional and phantom MAEs in crowded and non-crowded conditions, and when attention was directed to the adapting stimulus and when it was diverted away from the adapting stimulus. The results show that: (i) the phantom MAE is weaker than the conventional MAE, for both non-crowded and crowded conditions, and when attention was focused on the adapting stimulus and when it was diverted from it, (ii) conventional and phantom MAEs in the crowded condition are weaker than in the non-crowded condition. Analysis conducted to assess the effect of crowding on high-level of motion adaptation suggests that crowding is likely to affect the awareness of the adapting stimulus rather than degrading its sensory representation, (iii) for high-level of motion processing the attentional manipulation does not affect the strength of either conventional or phantom MAEs, neither in the non-crowded nor in the crowded conditions. These results suggest that high-level MAEs do not depend on attention and that at high-level of motion adaptation the effects of crowding are not modulated by attention. PMID:25615577
Jeon, Jae-Hyung; Metzler, Ralf
2010-02-01
Motivated by subdiffusive motion of biomolecules observed in living cells, we study the stochastic properties of a non-Brownian particle whose motion is governed by either fractional Brownian motion or the fractional Langevin equation and restricted to a finite domain. We investigate by analytic calculations and simulations how time-averaged observables (e.g., the time-averaged mean-squared displacement and displacement correlation) are affected by spatial confinement and dimensionality. In particular, we study the degree of weak ergodicity breaking and scatter between different single trajectories for this confined motion in the subdiffusive domain. The general trend is that deviations from ergodicity are decreased with decreasing size of the movement volume and with increasing dimensionality. We define the displacement correlation function and find that this quantity shows distinct features for fractional Brownian motion, fractional Langevin equation, and continuous time subdiffusion, such that it appears an efficient measure to distinguish these different processes based on single-particle trajectory data.
Electromagnetic torques in the core and resonant excitation of decadal polar motion
NASA Astrophysics Data System (ADS)
Mound, Jon E.
2005-02-01
Motion of the rotation axis of the Earth contains decadal variations with amplitudes on the order of 10 mas. The origin of these decadal polar motions is unknown. A class of rotational normal modes of the core-mantle system termed torsional oscillations are known to affect the length of day (LOD) at decadal periods and have also been suggested as a possible excitation source for the observed decadal polar motion. Torsional oscillations involve relative motion between the outer core and the surrounding solid bodies, producing electromagnetic torques at the inner-core boundary (ICB) and core-mantle boundary (CMB). It has been proposed that the ICB torque can explain the excitation of the approximately 30-yr-period polar motion termed the Markowitz wobble. This paper uses the results of a torsional oscillation model to calculate the torques generated at Markowitz and other decadal periods and finds, in contrast to previous results, that electromagnetic torques at the ICB can not explain the observed polar motion.
Multichannel techniques for motion artifacts removal from electrocardiographic signals.
Milanesi, M; Martini, N; Vanello, N; Positano, V; Santarelli, M F; Paradiso, R; De Rossi, D; Landini, L
2006-01-01
Electrocardiographic (ECG) signals are affected by several kinds of artifacts, that may hide vital signs of interest. Motion artifacts, due to the motion of the electrodes in relation to patient skin, are particularly frequent in bioelectrical signals acquired by wearable systems. In this paper we propose different approaches in order to get rid of motion confounds. The first approach we follow starts from measuring electrode motion provided by an accelerometer placed on the electrode and use this measurement in an adaptive filtering system to remove the noise present in the ECG. The second approach is based on independent component analysis methods applied to multichannel ECG recordings; we propose to use both instantaneous model and a frequency domain implementation of the convolutive model that accounts for different paths of the source signals to the electrodes.
Motion Alters Color Appearance
Hong, Sang-Wook; Kang, Min-Suk
2016-01-01
Chromatic induction compellingly demonstrates that chromatic context as well as spectral lights reflected from an object determines its color appearance. Here, we show that when one colored object moves around an identical stationary object, the perceived saturation of the stationary object decreases dramatically whereas the saturation of the moving object increases. These color appearance shifts in the opposite directions suggest that normalization induced by the object’s motion may mediate the shift in color appearance. We ruled out other plausible alternatives such as local adaptation, attention, and transient neural responses that could explain the color shift without assuming interaction between color and motion processing. These results demonstrate that the motion of an object affects both its own color appearance and the color appearance of a nearby object, suggesting a tight coupling between color and motion processing. PMID:27824098
Abraham, Anke
2008-06-01
According to the special view of natural sciences, ageing processes are connected with measurable changes in the body. At the same time we know little about how bodily change is experienced and the subjective acceptance of the body during aging. Therefore a perspective with respect to the body has to be systematically embraced in gerontology. Knowledge perspectives and the view of the body are exemplified in theory and by analysing a case. The knowledge of experience and sense of body and motion in a person's life allows the creation of stimulating offers of growth development and health in age.
Demonstrating the Direction of Angular Velocity in Circular Motion
NASA Astrophysics Data System (ADS)
Demircioglu, Salih; Yurumezoglu, Kemal; Isik, Hakan
2015-09-01
Rotational motion is ubiquitous in nature, from astronomical systems to household devices in everyday life to elementary models of atoms. Unlike the tangential velocity vector that represents the instantaneous linear velocity (magnitude and direction), an angular velocity vector is conceptually more challenging for students to grasp. In physics classrooms, the direction of an angular velocity vector is taught by the right-hand rule, a mnemonic tool intended to aid memory. A setup constructed for instructional purposes may provide students with a more easily understood and concrete method to observe the direction of the angular velocity. This article attempts to demonstrate the angular velocity vector using the observable motion of a screw mounted to a remotely operated toy car.
Juvenile arthritis (JA) is arthritis that happens in children. It causes joint swelling, pain, stiffness, and loss of motion. It can affect any joint, but ... of JA that children get is juvenile idiopathic arthritis. There are several other forms of arthritis affecting ...
Kan, Andrey; Tan, Yan-Hong; Angrisano, Fiona; Hanssen, Eric; Rogers, Kelly L; Whitehead, Lachlan; Mollard, Vanessa P; Cozijnsen, Anton; Delves, Michael J; Crawford, Simon; Sinden, Robert E; McFadden, Geoffrey I; Leckie, Christopher; Bailey, James; Baum, Jake
2014-05-01
Motility is a fundamental part of cellular life and survival, including for Plasmodium parasites--single-celled protozoan pathogens responsible for human malaria. The motile life cycle forms achieve motility, called gliding, via the activity of an internal actomyosin motor. Although gliding is based on the well-studied system of actin and myosin, its core biomechanics are not completely understood. Currently accepted models suggest it results from a specifically organized cellular motor that produces a rearward directional force. When linked to surface-bound adhesins, this force is passaged to the cell posterior, propelling the parasite forwards. Gliding motility is observed in all three life cycle stages of Plasmodium: sporozoites, merozoites and ookinetes. However, it is only the ookinetes--formed inside the midgut of infected mosquitoes--that display continuous gliding without the necessity of host cell entry. This makes them ideal candidates for invasion-free biomechanical analysis. Here we apply a plate-based imaging approach to study ookinete motion in three-dimensional (3D) space to understand Plasmodium cell motility and how movement facilitates midgut colonization. Using single-cell tracking and numerical analysis of parasite motion in 3D, our analysis demonstrates that ookinetes move with a conserved left-handed helical trajectory. Investigation of cell morphology suggests this trajectory may be based on the ookinete subpellicular cytoskeleton, with complementary whole and subcellular electron microscopy showing that, like their motion paths, ookinetes share a conserved left-handed corkscrew shape and underlying twisted microtubular architecture. Through comparisons of 3D movement between wild-type ookinetes and a cytoskeleton-knockout mutant we demonstrate that perturbation of cell shape changes motion from helical to broadly linear. Therefore, while the precise linkages between cellular architecture and actomyosin motor organization remain unknown, our analysis suggests that the molecular basis of cell shape may, in addition to motor force, be a key adaptive strategy for malaria parasite dissemination and, as such, transmission. © 2014 The Authors. Cellular Microbiology published by John Wiley & Sons Ltd.
Dziuda, Lukasz; Biernacki, Marcin P; Baran, Paulina M; Truszczyński, Olaf E
2014-05-01
In the study, we checked: 1) how the simulator test conditions affect the severity of simulator sickness symptoms; 2) how the severity of simulator sickness symptoms changes over time; and 3) whether the conditions of the simulator test affect the severity of these symptoms in different ways, depending on the time that has elapsed since the performance of the task in the simulator. We studied 12 men aged 24-33 years (M = 28.8, SD = 3.26) using a truck simulator. The SSQ questionnaire was used to assess the severity of the symptoms of simulator sickness. Each of the subjects performed three 30-minute tasks running along the same route in a driving simulator. Each of these tasks was carried out in a different simulator configuration: A) fixed base platform with poor visibility; B) fixed base platform with good visibility; and C) motion base platform with good visibility. The measurement of the severity of the simulator sickness symptoms took place in five consecutive intervals. The results of the analysis showed that the simulator test conditions affect in different ways the severity of the simulator sickness symptoms, depending on the time which has elapsed since performing the task on the simulator. The simulator sickness symptoms persisted at the highest level for the test conditions involving the motion base platform. Also, when performing the tasks on the motion base platform, the severity of the simulator sickness symptoms varied depending on the time that had elapsed since performing the task. Specifically, the addition of motion to the simulation increased the oculomotor and disorientation symptoms reported as well as the duration of the after-effects. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Carmo, A.A.; Kleiner, A.F.R.; Lobo da Costa, P.H.; Barros, R.M.L.
2012-01-01
The aim of this study was to analyze the alterations of arm and leg movements of patients during stroke gait. Joint angles of upper and lower limbs and spatiotemporal variables were evaluated in two groups: hemiparetic group (HG, 14 hemiparetic men, 53 ± 10 years) and control group (CG, 7 able-bodied men, 50 ± 4 years). The statistical analysis was based on the following comparisons (P ≤ 0.05): 1) right versus left sides of CG; 2) affected (AF) versus unaffected (UF) sides of HG; 3) CG versus both the affected and unaffected sides of HG, and 4) an intracycle comparison of the kinematic continuous angular variables between HG and CG. This study showed that the affected upper limb motion in stroke gait was characterized by a decreased range of motion of the glenohumeral (HG: 6.3 ± 4.5, CG: 20.1 ± 8.2) and elbow joints (AF: 8.4 ± 4.4, UF: 15.6 ± 7.6) on the sagittal plane and elbow joint flexion throughout the cycle (AF: 68.2 ± 0.4, CG: 46.8 ± 2.7). The glenohumeral joint presented a higher abduction angle (AF: 14.2 ± 1.6, CG: 11.5 ± 4.0) and a lower external rotation throughout the cycle (AF: 4.6 ± 1.2, CG: 22.0 ± 3.0). The lower limbs showed typical alterations of the stroke gait patterns. Thus, the changes in upper and lower limb motion of stroke gait were identified. The description of upper limb motion in stroke gait is new and complements gait analysis. PMID:22473324
Al Nima, Ali; Kjell, Oscar N.E.
2014-01-01
Background. An important outcome from the debate on whether wellness equals happiness, is the need of research focusing on how psychological well-being might influence humans’ ability to adapt to the changing environment and live in harmony. To get a detailed picture of the influence of positive and negative affect, the current study employed the affective profiles model in which individuals are categorised into groups based on either high positive and low negative affect (self-fulfilling); high positive and high negative affect (high affective); low positive and low negative affect (low affective); and high negative and low positive affect (self-destructive). The aims were to (1) investigate differences between affective profiles in psychological well-being and harmony and (2) how psychological well-being and its dimensions relate to harmony within the four affective profiles. Method. 500 participants (mean age = 34.14 years, SD. = ±12.75 years; 187 males and 313 females) were recruited online and required to answer three self-report measures: The Positive Affect and Negative Affect Schedule; The Scales of Psychological Well-Being (short version) and The Harmony in Life Scale. We conducted a Multivariate Analysis of Variance where the affective profiles and gender were the independent factors and psychological well-being composite score, its six dimensions as well as the harmony in life score were the dependent factors. In addition, we conducted four multi-group (i.e., the four affective profiles) moderation analyses with the psychological well-being dimensions as predictors and harmony in life as the dependent variables. Results. Individuals categorised as self-fulfilling, as compared to the other profiles, tended to score higher on the psychological well-being dimensions: positive relations, environmental mastery, self-acceptance, autonomy, personal growth, and purpose in life. In addition, 47% to 66% of the variance of the harmony in life was explained by the dimensions of psychological well-being within the four affective profiles. Specifically, harmony in life was significantly predicted by environmental mastery and self-acceptance across all affective profiles. However, for the low affective group high purpose in life predicted low levels of harmony in life. Conclusions. The results demonstrated that affective profiles systematically relate to psychological well-being and harmony in life. Notably, individuals categorised as self-fulfilling tended to report higher levels of both psychological well-being and harmony in life when compared with the other profiles. Meanwhile individuals in the self-destructive group reported the lowest levels of psychological well-being and harmony when compared with the three other profiles. It is proposed that self-acceptance and environmental acceptance might enable individuals to go from self-destructive to a self-fulfilling state that also involves harmony in life. PMID:24688843
Pilates and Dance to Breast Cancer Patients Undergoing Treatment
2017-08-12
Breast Cancer; Quality of Life; Lymphedema; Fatigue; Depressive Symptoms; Body Image; Self Esteem; Optimism; Sexual Function Disturbances; Stress; Sleep Disturbance; Pain; Muscular Weakness; Postural Balance; Range of Motion; Cardiorespiratory Fitness
Becoming Dragon: a mixed reality durational performance in Second Life
NASA Astrophysics Data System (ADS)
Cárdenas, Micha; Head, Christopher; Margolis, Todd; Greco, Kael
2009-02-01
The goal for Becoming Dragon was to develop a working, immersive Mixed Reality system by using a motion capture system and head mounted display to control a character in Second Life - a Massively Multiplayer Online 3D environment - in order to examine a number of questions regarding identity, gender and the transformative potential of technology. This performance was accomplished through a collaboration between Micha Cardenas, the performer and technical director, Christopher Head, Kael Greco, Benjamin Lotan, Anna Storelli and Elle Mehrmand. The plan for this project was to model the performer's physical environment to enable them to live in the virtual environment for extended amounts of time, using an approach of Mixed Reality, where the physical world is mapped into the virtual. I remain critical of the concept of Mixed Reality, as it presents an idea of realities as totalities and as objective essences independent of interpretation through the symbolic order. Part of my goal with this project is to explore identity as a process of social feedback, in the sense that Donna Haraway describes "becoming with"iii, as well as to explore the concept of Reality Spectrum that Augmentology.com discusses, thinking about states such as AFK (Away From Keyboard) that are in-between virtual and corporeal presence.iv Both of these ideas are ways of overcoming the dualisms of mind/body, real/virtual and self/other that have been a problematic part of thinking about technology for so long. Towards thinking beyond these binaries, Anna Munster offers a concept of enfolding the body and technologyv, building on Gilles Deleuze's notion of the baroque fold. She says "the superfold... opens up for us a twisted topology of code folding back upon itself without determinate start or end points: we now live in a time and space in which body and information are thoroughly imbricated."vi She elaborates on this notion of body and code as becoming with each other saying "the incorporeal vectors of digital information draw out the capacities of our bodies to become other than matter conceived as a mere vessel for consciousness or a substrate for signal... we may also conceive of these experiences as a new territory made possible by the fact that our bodies are immanently open to these kinds of technically symbiotic transformations"vii. A number of the technologies used in this performance were used in an attempt to blur the line between the actual and the digital, such as motion capture, live video streaming into Second Life and 3D fabrication of physical copies of Second Life avatars. The performance was developed using the following components: - An Emagin Z800 immersive head mounted display (HMD) allowed the performer to move around in the physical environment within Calit2 and still remain "in game". Head tracking and stereoscopic imagery help to provide a realistic feeling of immersion. We built on the University of Michigan 3D (UM3D) lab's stereoscopic patch for the Second Life client, updating it to work with the latest version of Second Life. - A motion tracking system. A Vicon MX40+ motion capture system was installed into the Visiting Artist Lab at CRCA, which served as the physical performance space, to allow real-time motion tracking data to be sent to a PC running Windows. Using this data, the plan was to map the physical motion in the real world back into game space, so that, for example, the performer could easily get to their food source or to the restroom. We developed a C++ bridge that includes a parser for the Vicon real time data stream in order to communicate this to the Second Life server to produce changes in avatar and object positions based on real physical movement. The goal was to get complete body gestures into Second Life in near real time. - A Puredata patch called Lila, developed by Shahrokh Yadegadi of UCSD, which was used to modulate the performer's voice, to provide a voice system that allowed chat ability in Second Life, which was less gendered and less human.
ERIC Educational Resources Information Center
Hynd, Cynthia; And Others
1997-01-01
Investigates changes in preservice teachers' conceptions about projectile motion brought about by a combination of reading and demonstration and appeal to usefulness. Results indicate the effectiveness of a combined Demo-Text condition on immediate posttests and effectiveness of text in producing long-term change. Analysis also indicates an…
ERIC Educational Resources Information Center
Kim, Nam-Gyoon; Park, Jong-Hee
2010-01-01
Recent research has demonstrated that Alzheimer's disease (AD) affects the visual sensory pathways, producing a variety of visual deficits, including the capacity to perceive structure-from-motion (SFM). Because the sensory areas of the adult brain are known to retain a large degree of plasticity, the present study was conducted to explore whether…
17 CFR 201.210 - Parties, limited participants and amici curiae.
Code of Federal Regulations, 2010 CFR
2010-04-01
... protection of investors or consumers, may be admitted as a party upon the filing of a written motion setting... proceeding may be in the public interest or for the protection of investors, may be admitted as a party upon... affecting the person's interests: (1) Procedure. Motions for leave to participate shall be in writing, shall...
Applying the Science of Learning to the Learning of Science: Newton's Second Law of Motion
ERIC Educational Resources Information Center
Lemmer, Miriam
2018-01-01
Science teaching and learning require knowledge about how learning takes place (cognition) and how learners interact with their surroundings (affective and sociocultural factors). The study reported on focussed on learning for understanding of Newton's second law of motion from a cognitive perspective that takes social factors into account. A…
ERIC Educational Resources Information Center
Hirai, Masahiro; Hiraki, Kazuo
2006-01-01
We investigated how the spatiotemporal structure of animations of biological motion (BM) affects brain activity. We measured event-related potentials (ERPs) during the perception of BM under four conditions: normal spatial and temporal structure; scrambled spatial and normal temporal structure; normal spatial and scrambled temporal structure; and…
Feng, Jing; Pierce, Rosemary; Do, K Patrick; Aiona, Michael
2014-01-01
Asymmetry between limbs in people with spastic hemiplegic cerebral palsy (HEMI) adversely affects limb coordination and energy generation and consumption. This study compared how the affected leg and the unaffected leg of children with HEMI would differ based on which leg trails. Full-body gait analysis data and force-plate data were analyzed for 31 children (11.9 ± 3.8 years) with HEMI and 23 children (11.1 ± 3.1 years) with typical development (TD). Results showed that peak posterior center of mass-center of pressure (COM-COP) inclination angles of HEMI were smaller than TD when the affected leg trailed but not when the unaffected leg trailed. HEMI showed greater peak medial COM-COP inclination angles and wider step width than TD, no matter which leg trailed. More importantly, when the affected leg of HEMI trailed, it did not perform enough positive work during double support to propel COM motion. Consequently, the unaffected leg had to perform additional positive work during the early portion of single support, which costs more energy. When the unaffected leg trailed, the affected leg performed more negative work during double support; therefore, more positive work was still needed during early single support, but energy efficiency was closer to that of TD. Energy recovery factor was lower when the affected leg trailed than when the unaffected leg trailed; both were lower than TD. These findings suggest that the trailing leg plays a significant role in propelling COM motion during double support, and the 'unaffected' side of HEMI may not be completely unaffected. It is important to strengthen both legs. Copyright © 2013 Elsevier B.V. All rights reserved.
Lindsey, Derek P; Kiapour, Ali; Yerby, Scott A; Goel, Vijay K
2018-03-18
To analyze how various implants placement variables affect sacroiliac (SI) joint range of motion. An experimentally validated finite element model of the lumbar spine and pelvis was used to simulate a fusion of the SI joint using various placement configurations of triangular implants (iFuse Implant System ® ). Placement configurations were varied by changing implant orientation, superior implant length, and number of implants. The range of motion of the SI joint was calculated using a constant moment of 10 N-m with a follower load of 400 N. The changes in motion were compared between the treatment groups to assess how the different variables affected the overall motion of the SI joint. Transarticular placement of 3 implants with superior implants that end in the middle of the sacrum resulted in the greatest reduction in range of motion (flexion/extension = 73%, lateral bending = 42%, axial rotation = 72%). The range of motions of the SI joints were reduced with use of transarticular orientation (9%-18%) when compared with an inline orientation. The use of a superior implant that ended mid-sacrum resulted in median reductions of (8%-14%) when compared with a superior implant that ended in the middle of the ala. Reducing the number of implants, resulted in increased SI joint range of motions for the 1 and 2 implant models of 29%-133% and 2%-39%, respectively, when compared with the 3 implant model. Using a validated finite element model we demonstrated that placement of 3 implants across the SI joint using a transarticular orientation with superior implant reaching the sacral midline resulted in the most stable construct. Additional clinical studies may be required to confirm these results.
Lindsey, Derek P; Kiapour, Ali; Yerby, Scott A; Goel, Vijay K
2018-01-01
AIM To analyze how various implants placement variables affect sacroiliac (SI) joint range of motion. METHODS An experimentally validated finite element model of the lumbar spine and pelvis was used to simulate a fusion of the SI joint using various placement configurations of triangular implants (iFuse Implant System®). Placement configurations were varied by changing implant orientation, superior implant length, and number of implants. The range of motion of the SI joint was calculated using a constant moment of 10 N-m with a follower load of 400 N. The changes in motion were compared between the treatment groups to assess how the different variables affected the overall motion of the SI joint. RESULTS Transarticular placement of 3 implants with superior implants that end in the middle of the sacrum resulted in the greatest reduction in range of motion (flexion/extension = 73%, lateral bending = 42%, axial rotation = 72%). The range of motions of the SI joints were reduced with use of transarticular orientation (9%-18%) when compared with an inline orientation. The use of a superior implant that ended mid-sacrum resulted in median reductions of (8%-14%) when compared with a superior implant that ended in the middle of the ala. Reducing the number of implants, resulted in increased SI joint range of motions for the 1 and 2 implant models of 29%-133% and 2%-39%, respectively, when compared with the 3 implant model. CONCLUSION Using a validated finite element model we demonstrated that placement of 3 implants across the SI joint using a transarticular orientation with superior implant reaching the sacral midline resulted in the most stable construct. Additional clinical studies may be required to confirm these results. PMID:29564210
NASA Astrophysics Data System (ADS)
Sothmann, T.; Gauer, T.; Wilms, M.; Werner, R.
2017-12-01
The purpose of this study is to introduce a novel approach to incorporate patient-specific breathing variability information into 4D dose simulation of volumetric arc therapy (VMAT)-based stereotactic body radiotherapy (SBRT) of extracranial metastases. Feasibility of the approach is illustrated by application to treatment planning and motion data of lung and liver metastasis patients. The novel 4D dose simulation approach makes use of a regression-based correspondence model that allows representing patient motion variability by breathing signal-steered interpolation and extrapolation of deformable image registration motion fields. To predict the internal patient motion during treatment with only external breathing signal measurements being available, the patients’ internal motion information and external breathing signals acquired during 4D CT imaging were correlated. Combining the correspondence model, patient-specific breathing signal measurements during treatment and time-resolved information about dose delivery, reconstruction of a motion variability-affected dose becomes possible. As a proof of concept, the proposed approach is illustrated by a retrospective 4D simulation of VMAT-based SBRT treatment of ten patients with 15 treated lung and liver metastases and known clinical endpoints for the individual metastases (local metastasis recurrence yes/no). Resulting 4D-simulated dose distributions were compared to motion-affected dose distributions estimated by standard 4D CT-only dose accumulation and the originally (i.e. statically) planned dose distributions by means of GTV D98 indices (dose to 98% of the GTV volume). A potential linkage of metastasis-specific endpoints to differences between GTV D98 indices of planned and 4D-simulated dose distributions was analyzed.
Schlottmann, Anne; Cole, Katy; Watts, Rhianna; White, Marina
2013-01-01
Humans, even babies, perceive causality when one shape moves briefly and linearly after another. Motion timing is crucial in this and causal impressions disappear with short delays between motions. However, the role of temporal information is more complex: it is both a cue to causality and a factor that constrains processing. It affects ability to distinguish causality from non-causality, and social from mechanical causality. Here we study both issues with 3- to 7-year-olds and adults who saw two computer-animated squares and chose if a picture of mechanical, social or non-causality fit each event best. Prior work fit with the standard view that early in development, the distinction between the social and physical domains depends mainly on whether or not the agents make contact, and that this reflects concern with domain-specific motion onset, in particular, whether the motion is self-initiated or not. The present experiments challenge both parts of this position. In Experiments 1 and 2, we showed that not just spatial, but also animacy and temporal information affect how children distinguish between physical and social causality. In Experiments 3 and 4 we showed that children do not seem to use spatio-temporal information in perceptual causality to make inferences about self- or other-initiated motion onset. Overall, spatial contact may be developmentally primary in domain-specific perceptual causality in that it is processed easily and is dominant over competing cues, but it is not the only cue used early on and it is not used to infer motion onset. Instead, domain-specific causal impressions may be automatic reactions to specific perceptual configurations, with a complex role for temporal information. PMID:23874308
Motion on an inclined plane and the nature of science
NASA Astrophysics Data System (ADS)
Pendrill, Ann-Marie; Ekström, Peter; Hansson, Lena; Mars, Patrik; Ouattara, Lassana; Ryan, Ulrika
2014-03-01
Friction is an important phenomenon in everyday life. All children are familiar with playground slides, which may thus be a good starting point for investigating friction. Motion on an inclined plane is a standard physics example. This paper presents an investigation of friction by a group of 11-year olds. How did they plan their investigations? What aspects of friction could they discern? What understanding of the nature of science was revealed—and developed—during their investigation and subsequent discussion with the teacher?
2016-02-16
Force should consider approaching the motion picture industry to produce a film about the life of Legendary Ace Robin Olds. This approach could capture...option must be investigated. Teaming with film producers is a valid way to promote the history of the Air Force, shaping a positive public image, and...morale. As a solution to increase Air Force warrior morale, the Air Force should consider approaching the motion picture industry to produce a film
Kiryu, Tohru; Yamada, Hiroshi; Jimbo, Masahiro; Bando, Takehiko
2004-01-01
Virtual reality (VR) is a promising technology in biomedical engineering, but at the same time enlarges another problem called cybersickness. Aiming at suppression of cybersicknes, we are investigating the influences of vection-induced images on the autonomic regulation quantitatively. We used the motion vectors to quantify image scenes and measured electrocardiogram, blood pressure, and respiration for evaluating the autonomic regulation. Using the estimated motion vectors, we further synthesized random-dot pattern images to survey which component of the global motion vectors seriously affected the autonomic regulation. The results showed that the zoom component with a specific frequency band (0.1-3.0 Hz) would induce sickness.
NASA Technical Reports Server (NTRS)
Rosenberg, M. J. F.; Kreutzberg, G. A.; Peters, B. T.; Reschke, M. F.
2017-01-01
Gravity transitions cause changes in the vestibulo-occular reflex (VOR), which manifests as poor gaze control, a decrement in dynamic visual acuity (the ability to maintain gaze while in motion), both of which are caused by retinal slip. Retinal slip, the inability to keep an image focused on the retina, can drive or worsen sensory conflict, resulting in motion sickness (MS). Currently 100% of returning crewmembers report MS symptoms, which might affect their ability to perform mission critical tasks immediately after landing. Reschke et al. (2007) demonstrate that stroboscopic vision goggles improve motion sickness onset and symptom severity in motion sickness driven by retinal slip.
Symeonidou, Evangelia-Regkina; Nordin, Andrew D.; Hairston, W. David
2018-01-01
More neuroscience researchers are using scalp electroencephalography (EEG) to measure electrocortical dynamics during human locomotion and other types of movement. Motion artifacts corrupt the EEG and mask underlying neural signals of interest. The cause of motion artifacts in EEG is often attributed to electrode motion relative to the skin, but few studies have examined EEG signals under head motion. In the current study, we tested how motion artifacts are affected by the overall mass and surface area of commercially available electrodes, as well as how cable sway contributes to motion artifacts. To provide a ground-truth signal, we used a gelatin head phantom with embedded antennas broadcasting electrical signals, and recorded EEG with a commercially available electrode system. A robotic platform moved the phantom head through sinusoidal displacements at different frequencies (0–2 Hz). Results showed that a larger electrode surface area can have a small but significant effect on improving EEG signal quality during motion and that cable sway is a major contributor to motion artifacts. These results have implications in the development of future hardware for mobile brain imaging with EEG. PMID:29614020
Satterthwaite, Theodore D.; Elliott, Mark A.; Gerraty, Raphael T.; Ruparel, Kosha; Loughead, James; Calkins, Monica E.; Eickhoff, Simon B.; Hakonarson, Hakon; Gur, Ruben C.; Gur, Raquel E.; Wolf, Daniel H.
2013-01-01
Several recent reports in large, independent samples have demonstrated the influence of motion artifact on resting-state functional connectivity MRI (rsfc-MRI). Standard rsfc-MRI preprocessing typically includes regression of confounding signals and band-pass filtering. However, substantial heterogeneity exists in how these techniques are implemented across studies, and no prior study has examined the effect of differing approaches for the control of motion-induced artifacts. To better understand how in-scanner head motion affects rsfc-MRI data, we describe the spatial, temporal, and spectral characteristics of motion artifacts in a sample of 348 adolescents. Analyses utilize a novel approach for describing head motion on a voxelwise basis. Next, we systematically evaluate the efficacy of a range of confound regression and filtering techniques for the control of motion-induced artifacts. Results reveal that the effectiveness of preprocessing procedures on the control of motion is heterogeneous, and that improved preprocessing provides a substantial benefit beyond typical procedures. These results demonstrate that the effect of motion on rsfc-MRI can be substantially attenuated through improved preprocessing procedures, but not completely removed. PMID:22926292
JPRS Report, Soviet Union, Kommunist.
1988-01-22
despite all trials. Today our literature, graphic arts, music , motion pictures and theater have their own Soviet clas- sics which embody the best...of the most sensitive and emotional aspects of social life: increased impressionability and responsiveness and a sharpened moral feeling "func- tion... musical life is becoming richer and filled with more individuality. It is as though culture and art are being restored in their truly complex
Chui, Chen-Shou; Yorke, Ellen; Hong, Linda
2003-07-01
Intensity-modulated radiation therapy can be conveniently delivered with a multileaf collimator. With this method, the entire field is not delivered at once, but rather it is composed of many subfields defined by the leaf positions as a function of beam on time. At any given instant, only these subfields are delivered. During treatment, if the organ moves, part of the volume may move in or out of these subfields. Due to this interplay between organ motion and leaf motion the delivered dose may be different from what was planned. In this work, we present a method that calculates the effects of organ motion on delivered dose. The direction of organ motion may be parallel or perpendicular to the leaf motion, and the effect can be calculated for a single fraction or for multiple fractions. Three breast patients and four lung patients were included in this study,with the amplitude of the organ motion varying from +/- 3.5 mm to +/- 10 mm, and the period varying from 4 to 8 seconds. Calculations were made for these patients with and without organ motion, and results were examined in terms of isodose distribution and dose volume histograms. Each calculation was repeated ten times in order to estimate the statistical uncertainties. For selected patients, calculations were also made with conventional treatment technique. The effects of organ motion on conventional techniques were compared relative to that on IMRT techniques. For breast treatment, the effect of organ motion primarily broadened the penumbra at the posterior field edge. The dose in the rest of the treatment volume was not significantly affected. For lung treatment, the effect also broadened the penumbra and degraded the coverage of the planning target volume (PTV). However, the coverage of the clinical target volume (CTV) was not much affected, provided the PTV margin was adequate. The same effects were observed for both IMRT and conventional treatment techniques. For the IMRT technique, the standard deviations of ten samples of a 30-fraction calculation were very small for all patients, implying that over a typical treatment course of 30 fractions, the delivered dose was very close to the expected value. Hence, under typical clinical conditions, the effect of organ motion on delivered dose can be calculated without considering the interplay between the organ motion and the leaf motion. It can be calculated as the weighted average of the dose distribution without organ motion with the distribution of organ motion. Since the effects of organ motion on dose were comparable for both IMRT and conventional techniques, the PTV margin should remain the same for both techniques.
Acceleration or deceleration of self-motion by the Marangoni effect
NASA Astrophysics Data System (ADS)
Matsuda, Yui; Suematsu, Nobuhiko J.; Kitahata, Hiroyuki; Ikura, Yumihiko S.; Nakata, Satoshi
2016-06-01
We investigated the water-depth dependence of the self-motion of a camphor disk and camphor boat. With increasing water depth, the speed of motion of the camphor disk increased, but that of the camphor boat decreased in an annular one-dimensional system. We discussed the difference in the water-depth dependence of the speed of the camphor objects in relation to Marangoni flow. We concluded that Marangoni flow, which became stronger with increasing the water depth, positively and negatively affected the speed of the disk and boat, respectively.
Air motions accompanying the development of a planetary wave critical layer
NASA Technical Reports Server (NTRS)
Salby, Murry L.; O'Sullivan, Donal; Callaghan, Patrick; Garcia, Rolando R.
1990-01-01
The horizontal air motions accompanying the development of a planetary wave critical layer are presently investigated on the sphere, in terms of wave amplitude, the characteristics of the zonal flow, and dissipation. While attention is given to adiabatic motions, which should furnish an upper bound on the redistribution of conserved quantities by eddy stirring, nonconservative processes may be important in determining how large a role eddy stirring actually plays in the redistribution of atmospheric constituents. Nonconservative processes may also influence tracer distributions by directly affecting dynamics.
Human Classification Based on Gestural Motions by Using Components of PCA
NASA Astrophysics Data System (ADS)
Aziz, Azri A.; Wan, Khairunizam; Za'aba, S. K.; B, Shahriman A.; Adnan, Nazrul H.; H, Asyekin; R, Zuradzman M.
2013-12-01
Lately, a study of human capabilities with the aim to be integrated into machine is the famous topic to be discussed. Moreover, human are bless with special abilities that they can hear, see, sense, speak, think and understand each other. Giving such abilities to machine for improvement of human life is researcher's aim for better quality of life in the future. This research was concentrating on human gesture, specifically arm motions for differencing the individuality which lead to the development of the hand gesture database. We try to differentiate the human physical characteristic based on hand gesture represented by arm trajectories. Subjects are selected from different type of the body sizes, and then acquired data undergo resampling process. The results discuss the classification of human based on arm trajectories by using Principle Component Analysis (PCA).
An efficient motion-resistant method for wearable pulse oximeter.
Yan, Yong-Sheng; Zhang, Yuan-Ting
2008-05-01
Reduction of motion artifact and power saving are crucial in designing a wearable pulse oximeter for long-term telemedicine application. In this paper, a novel algorithm, minimum correlation discrete saturation transform (MCDST) has been developed for the estimation of arterial oxygen saturation (SaO2), based on an optical model derived from photon diffusion analysis. The simulation shows that the new algorithm MCDST is more robust under low SNRs than the clinically verified motion-resistant algorithm discrete saturation transform (DST). Further, the experiment with different severity of motions demonstrates that MCDST has a slightly better performance than DST algorithm. Moreover, MCDST is more computationally efficient than DST because the former uses linear algebra instead of the time-consuming adaptive filter used by latter, which indicates that MCDST can reduce the required power consumption and circuit complexity of the implementation. This is vital for wearable devices, where the physical size and long battery life are crucial.
High correlation between performance on a virtual-reality simulator and real-life cataract surgery.
Thomsen, Ann Sofia Skou; Smith, Phillip; Subhi, Yousif; Cour, Morten la; Tang, Lilian; Saleh, George M; Konge, Lars
2017-05-01
To investigate the correlation in performance of cataract surgery between a virtual-reality simulator and real-life surgery using two objective assessment tools with evidence of validity. Cataract surgeons with varying levels of experience were included in the study. All participants performed and videorecorded three standard cataract surgeries before completing a proficiency-based test on the EyeSi virtual-reality simulator. Standard cataract surgeries were defined as: (1) surgery performed under local anaesthesia, (2) patient age >60 years, and (3) visual acuity >1/60 preoperatively. A motion-tracking score was calculated by multiplying average path length and average number of movements from the three real-life surgical videos of full procedures. The EyeSi test consisted of five abstract and two procedural modules: intracapsular navigation, antitremor training, intracapsular antitremor training, forceps training, bimanual training, capsulorhexis and phaco divide and conquer. Eleven surgeons were enrolled. After a designated warm-up period, the proficiency-based test on the EyeSi simulator was strongly correlated to real-life performance measured by motion-tracking software of cataract surgical videos with a Pearson correlation coefficient of -0.70 (p = 0.017). Performance on the EyeSi simulator is significantly and highly correlated to real-life surgical performance. However, it is recommended that performance assessments are made using multiple data sources. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Investigation on the radial micro-motion about piston of axial piston pump
NASA Astrophysics Data System (ADS)
Xu, Bing; Zhang, Junhui; Yang, Huayong; Zhang, Bin
2013-03-01
The limit working parameters and service life of axial piston pump are determined by the carrying ability and lubrication characteristic of its key friction pairs. Therefore, the design and optimization of the key friction pairs are always a key and difficult problem in the research on axial piston pump. In the traditional research on piston/cylinder pair, the assembly relationship of piston and cylinder bore is simplified into ideal cylindrical pair, which can not be used to analyze the influences of radial micro-motion of piston on the distribution characteristics of oil-film thickness and pressure in details. In this paper, based on the lubrication theory of the oil film, a numerical simulation model is built, taking the influences of roughness, elastic deformation of piston and pressure-viscosity effect into consideration. With the simulation model, the dynamic characteristics of the radial micro-motion and pressure distribution are analyzed, and the relationships between radial micro-motion and carrying ability, lubrication condition, and abrasion are discussed. Furthermore, a model pump for pressure distribution measurement of oil film between piston and cylinder bore is designed. The comparison of simulation and experimental results of pressure distribution shows that the simulation model has high accuracy. The experiment and simulation results demonstrate that the pressure distribution has peak values that are much higher than the boundary pressure in the piston chamber due to the radial micro-motion, and the abrasion of piston takes place mainly on the hand close to piston ball. In addition, improvement of manufacturing roundness and straightness of piston and cylinder bore is helpful to improve the carrying ability of piston/cylinder pair. The proposed research provides references for designing piston/cylinder pair, and helps to prolong the service life of axial piston pump.
Approximate stresses in 2-D flat elastic contact fretting problems
NASA Astrophysics Data System (ADS)
Urban, Michael Rene
Fatigue results from the cyclic loading of a solid body. If the body subject to fatigue is in contact with another body and relative sliding motion occurs between these two bodies, then rubbing surface damage can accelerate fatigue failure. The acceleration of fatigue failure is especially important if the relative motion between the two bodies results in surface damage without excessive surface removal via wear. The situation just described is referred to as fretting fatigue. Understanding of fretting fatigue is greatly enhanced if the stress state associated with fretting can be characterized. For Hertzian contact, this can readily be done. Unfortunately, simple stress formulae are not available for flat body contact. The primary result of the present research is the development of a new, reasonably accurate, approximate closed form expression for 2-dimensional contact stresses which has been verified using finite element modeling. This expression is also combined with fracture mechanics to provide a simple method of determining when a crack is long enough to no longer be affected by the contact stress field. Lower bounds on fatigue life can then easily be calculated using fracture mechanics. This closed form expression can also be used to calculate crack propagation within the contact stress field. The problem of determining the cycles required to generate an initial crack and what to choose as an initial crack size is unresolved as it is in non-fretting fatigue.
A Unified Global Reference Frame of Vertical Crustal Movements by Satellite Laser Ranging.
Zhu, Xinhui; Wang, Ren; Sun, Fuping; Wang, Jinling
2016-02-08
Crustal movement is one of the main factors influencing the change of the Earth system, especially in its vertical direction, which affects people's daily life through the frequent occurrence of earthquakes, geological disasters, and so on. In order to get a better study and application of the vertical crustal movement,as well as its changes, the foundation and prerequisite areto devise and establish its reference frame; especially, a unified global reference frame is required. Since SLR (satellite laser ranging) is one of the most accurate space techniques for monitoring geocentric motion and can directly measure the ground station's geocentric coordinates and velocities relative to the centre of the Earth's mass, we proposed to take the vertical velocity of the SLR technique in the ITRF2008 framework as the reference frame of vertical crustal motion, which we defined as the SLR vertical reference frame (SVRF). The systematic bias between other velocity fields and the SVRF was resolved by using the GPS (Global Positioning System) and VLBI (very long baseline interferometry) velocity observations, and the unity of other velocity fields and SVRF was realized,as well. The results show that it is feasible and suitable to take the SVRF as a reference frame, which has both geophysical meanings and geodetic observations, so we recommend taking the SLR vertical velocity under ITRF2008 as the global reference frame of vertical crustal movement.
Meso-scale turbulence in living fluids
Wensink, Henricus H.; Dunkel, Jörn; Heidenreich, Sebastian; Drescher, Knut; Goldstein, Raymond E.; Löwen, Hartmut; Yeomans, Julia M.
2012-01-01
Turbulence is ubiquitous, from oceanic currents to small-scale biological and quantum systems. Self-sustained turbulent motion in microbial suspensions presents an intriguing example of collective dynamical behavior among the simplest forms of life and is important for fluid mixing and molecular transport on the microscale. The mathematical characterization of turbulence phenomena in active nonequilibrium fluids proves even more difficult than for conventional liquids or gases. It is not known which features of turbulent phases in living matter are universal or system-specific or which generalizations of the Navier–Stokes equations are able to describe them adequately. Here, we combine experiments, particle simulations, and continuum theory to identify the statistical properties of self-sustained meso-scale turbulence in active systems. To study how dimensionality and boundary conditions affect collective bacterial dynamics, we measured energy spectra and structure functions in dense Bacillus subtilis suspensions in quasi-2D and 3D geometries. Our experimental results for the bacterial flow statistics agree well with predictions from a minimal model for self-propelled rods, suggesting that at high concentrations the collective motion of the bacteria is dominated by short-range interactions. To provide a basis for future theoretical studies, we propose a minimal continuum model for incompressible bacterial flow. A detailed numerical analysis of the 2D case shows that this theory can reproduce many of the experimentally observed features of self-sustained active turbulence. PMID:22908244
Meso-scale turbulence in living fluids.
Wensink, Henricus H; Dunkel, Jörn; Heidenreich, Sebastian; Drescher, Knut; Goldstein, Raymond E; Löwen, Hartmut; Yeomans, Julia M
2012-09-04
Turbulence is ubiquitous, from oceanic currents to small-scale biological and quantum systems. Self-sustained turbulent motion in microbial suspensions presents an intriguing example of collective dynamical behavior among the simplest forms of life and is important for fluid mixing and molecular transport on the microscale. The mathematical characterization of turbulence phenomena in active nonequilibrium fluids proves even more difficult than for conventional liquids or gases. It is not known which features of turbulent phases in living matter are universal or system-specific or which generalizations of the Navier-Stokes equations are able to describe them adequately. Here, we combine experiments, particle simulations, and continuum theory to identify the statistical properties of self-sustained meso-scale turbulence in active systems. To study how dimensionality and boundary conditions affect collective bacterial dynamics, we measured energy spectra and structure functions in dense Bacillus subtilis suspensions in quasi-2D and 3D geometries. Our experimental results for the bacterial flow statistics agree well with predictions from a minimal model for self-propelled rods, suggesting that at high concentrations the collective motion of the bacteria is dominated by short-range interactions. To provide a basis for future theoretical studies, we propose a minimal continuum model for incompressible bacterial flow. A detailed numerical analysis of the 2D case shows that this theory can reproduce many of the experimentally observed features of self-sustained active turbulence.
McCammon, J. Andrew
2011-01-01
Chagas' disease, caused by the protozoan parasite Trypanosoma cruzi (T. cruzi), is a life-threatening illness affecting 11–18 million people. Currently available treatments are limited, with unacceptable efficacy and safety profiles. Recent studies have revealed an essential T. cruzi proline racemase enzyme (TcPR) as an attractive candidate for improved chemotherapeutic intervention. Conformational changes associated with substrate binding to TcPR are believed to expose critical residues that elicit a host mitogenic B-cell response, a process contributing to parasite persistence and immune system evasion. Characterization of the conformational states of TcPR requires access to long-time-scale motions that are currently inaccessible by standard molecular dynamics simulations. Here we describe advanced accelerated molecular dynamics that extend the effective simulation time and capture large-scale motions of functional relevance. Conservation and fragment mapping analyses identified potential conformational epitopes located in the vicinity of newly identified transient binding pockets. The newly identified open TcPR conformations revealed by this study along with knowledge of the closed to open interconversion mechanism advances our understanding of TcPR function. The results and the strategy adopted in this work constitute an important step toward the rationalization of the molecular basis behind the mitogenic B-cell response of TcPR and provide new insights for future structure-based drug discovery. PMID:22022240
de Oliveira, César Augusto F; Grant, Barry J; Zhou, Michelle; McCammon, J Andrew
2011-10-01
Chagas' disease, caused by the protozoan parasite Trypanosoma cruzi (T. cruzi), is a life-threatening illness affecting 11-18 million people. Currently available treatments are limited, with unacceptable efficacy and safety profiles. Recent studies have revealed an essential T. cruzi proline racemase enzyme (TcPR) as an attractive candidate for improved chemotherapeutic intervention. Conformational changes associated with substrate binding to TcPR are believed to expose critical residues that elicit a host mitogenic B-cell response, a process contributing to parasite persistence and immune system evasion. Characterization of the conformational states of TcPR requires access to long-time-scale motions that are currently inaccessible by standard molecular dynamics simulations. Here we describe advanced accelerated molecular dynamics that extend the effective simulation time and capture large-scale motions of functional relevance. Conservation and fragment mapping analyses identified potential conformational epitopes located in the vicinity of newly identified transient binding pockets. The newly identified open TcPR conformations revealed by this study along with knowledge of the closed to open interconversion mechanism advances our understanding of TcPR function. The results and the strategy adopted in this work constitute an important step toward the rationalization of the molecular basis behind the mitogenic B-cell response of TcPR and provide new insights for future structure-based drug discovery.
A Unified Global Reference Frame of Vertical Crustal Movements by Satellite Laser Ranging
Zhu, Xinhui; Wang, Ren; Sun, Fuping; Wang, Jinling
2016-01-01
Crustal movement is one of the main factors influencing the change of the Earth system, especially in its vertical direction, which affects people’s daily life through the frequent occurrence of earthquakes, geological disasters, and so on. In order to get a better study and application of the vertical crustal movement, as well as its changes, the foundation and prerequisite areto devise and establish its reference frame; especially, a unified global reference frame is required. Since SLR (satellite laser ranging) is one of the most accurate space techniques for monitoring geocentric motion and can directly measure the ground station’s geocentric coordinates and velocities relative to the centre of the Earth’s mass, we proposed to take the vertical velocity of the SLR technique in the ITRF2008 framework as the reference frame of vertical crustal motion, which we defined as the SLR vertical reference frame (SVRF). The systematic bias between other velocity fields and the SVRF was resolved by using the GPS (Global Positioning System) and VLBI (very long baseline interferometry) velocity observations, and the unity of other velocity fields and SVRF was realized, as well. The results show that it is feasible and suitable to take the SVRF as a reference frame, which has both geophysical meanings and geodetic observations, so we recommend taking the SLR vertical velocity under ITRF2008 as the global reference frame of vertical crustal movement. PMID:26867197
Khan, Sara; Farooq, Umar; Kurnikova, Maria
2016-11-28
In the present studies, we analyzed the influence of temperature on the stability and dynamics of the α subunit of tryptophan synthase (TRPS) from hyperthermophilic, mesophilic, and psychrophilic homologues at different temperatures by molecular dynamics simulations. Employing different indicators such as root-mean-square deviations, root-mean-square fluctuations, principal component analysis, and free energy landscapes, this study manifests the diverse behavior of these homologues with changes in temperature. Especially, an enhancement in the collective motions, classified as representative motions, is observed at high temperature. Similarly, the criterion for the selection of electrostatic interactions in terms of their life span (duty cycle) has indeed helped in identifying the short- and long-lived electrostatic interactions and how they affect the protein's overall stability at different temperatures. Rigidity and flexibility patterns of the homologous proteins are examined using FIRST software along with the calculation of duty cycles with various threshold limits at different temperatures. Rigid cluster decomposition in TRPS of psychrophilic, mesophilic, and hyperthermophilic origin identifies the flexible and rigid regions in the protein. Early loss of rigidity is observed in mesophilic TRPS via loss of contact between the major fragments of the protein compared with the other homologues. In spite of the high similarity of their three-dimensional structures, the overall responses of the three proteins to varying temperatures are significantly different.
Sangtarash, F; Manshadi, F D; Sadeghi, A
2015-08-01
Thoracic kyphosis angle (TKA) increases with osteoporosis. This study aimed to investigate the relationship between magnitude of TKA and quality of life and gait performance in 34 osteoporotic women. Our results suggest that increasing TKA is significantly associated with decreasing quality of life (r = -0.48, p < 0.005) and gait performance (r = -0.74, p < 0.0005). Osteoporosis and its related effects are threatening health and quality of life especially in postmenopausal women. Increased thoracic kyphosis angle (TKA), as one of the most common adverse musculoskeletal changes, could be regarded as a quantitative index for osteoporotic patients' assessment. Dual digital inclinometer (DDI) is one of the latest tools for non-invasive TKA measurement. The main purpose of this study was to determine whether a relationship existed between the magnitude of TKA, gait performance, and quality of life in a group of osteoporotic women. Thirty-four osteoporotic women, aged 50-68, participated in this descriptive analytic study. The magnitude of TKA measured by using DDI and expressed as the kyphosis index (KI). Quality of life and gait performance were assessed using short form 36 (SF36) questionnaire and functional gait assessment test, respectively. Back extension range of motion (ROM) and back extensor strength were also assessed. Pearson's correlation test was used to analyze the data, with the significance level of p < 0.05. The findings revealed a statistically significant negative correlation between KI and quality of life (r = -0.48, p < 0.005) and KI and gait performance (r = -0.74, p < 0.0005). There was also a significantly negative relation between KI and back extension ROM and back extensor strength (p < 0.05). The results of this study demonstrated that increased thoracic kyphosis negatively affects gait performance and quality of life. This finding could be regarded as an important implication for therapist to pay more attention to the magnitude of thoracic kyphosis angle and its changes, when selecting appropriate therapeutic methods to improve gait performance and quality of life in osteoporosis women.
Pengpen, T; Soleimani, M
2015-06-13
Cone beam computed tomography (CBCT) is an imaging modality that has been used in image-guided radiation therapy (IGRT). For applications such as lung radiation therapy, CBCT images are greatly affected by the motion artefacts. This is mainly due to low temporal resolution of CBCT. Recently, a dual modality of electrical impedance tomography (EIT) and CBCT has been proposed, in which the high temporal resolution EIT imaging system provides motion data to a motion-compensated algebraic reconstruction technique (ART)-based CBCT reconstruction software. High computational time associated with ART and indeed other variations of ART make it less practical for real applications. This paper develops a motion-compensated conjugate gradient least-squares (CGLS) algorithm for CBCT. A motion-compensated CGLS offers several advantages over ART-based methods, including possibilities for explicit regularization, rapid convergence and parallel computations. This paper for the first time demonstrates motion-compensated CBCT reconstruction using CGLS and reconstruction results are shown in limited data CBCT considering only a quarter of the full dataset. The proposed algorithm is tested using simulated motion data in generic motion-compensated CBCT as well as measured EIT data in dual EIT-CBCT imaging. © 2015 The Author(s) Published by the Royal Society. All rights reserved.
Relaxing USOS Solar Array Constraints for Russian Vehicle Undocking
NASA Technical Reports Server (NTRS)
Menkin, Evgeny; Schrock, Mariusz; Schrock, Rita; Zaczek, Mariusz; Gomez, Susan; Lee, Roscoe; Bennet, George
2011-01-01
With the retirement of Space Shuttle cargo delivery capability and the ten year life extension of the International Space Station (ISS) more emphasis is being put on preservation of the service life of ISS critical components. Current restrictions on the United States Orbital Segment (USOS) Solar Array (SA) positioning during Russian Vehicle (RV) departure from ISS nadir and zenith ports cause SA to be positioned in the plume field of Service Module thrusters and lead to degradation of SAs as well as potential damage to Sun tracking Beta Gimbal Assemblies (BGA). These restrictions are imposed because of the single fault tolerant RV Motion Control System (MCS), which does not meet ISS Safety requirements for catastrophic hazards and dictates 16 degree Solar Array Rotary Joint position, which ensures that ISS and RV relative motion post separation, does lead to collision. The purpose of this paper is to describe a methodology and the analysis that was performed to determine relative motion trajectories of the ISS and separating RV for nominal and contingency cases. Analysis was performed in three phases that included ISS free drift prior to Visiting Vehicle separation, ISS and Visiting Vehicle relative motion analysis and clearance analysis. First, the ISS free drift analysis determined the worst case attitude and attitude rate excursions prior to RV separation based on a series of different configurations and mass properties. Next, the relative motion analysis calculated the separation trajectories while varying the initial conditions, such as docking mechanism performance, Visiting Vehicle MCS failure, departure port location, ISS attitude and attitude rates at the time of separation, etc. The analysis employed both orbital mechanics and rigid body rotation calculations while accounting for various atmospheric conditions and gravity gradient effects. The resulting relative motion trajectories were then used to determine the worst case separation envelopes during the clearance analysis. Analytical models were developed individually for each stage and the results were used to build initial conditions for the following stages. In addition to the analysis approach, this paper also discusses the analysis results, showing worst case relative motion envelopes, the recommendations for ISS appendage positioning and the suggested approach for future analyses.
Motion Artifact Quantification and Sensor Fusion for Unobtrusive Health Monitoring.
Hoog Antink, Christoph; Schulz, Florian; Leonhardt, Steffen; Walter, Marian
2017-12-25
Sensors integrated into objects of everyday life potentially allow unobtrusive health monitoring at home. However, since the coupling of sensors and subject is not as well-defined as compared to a clinical setting, the signal quality is much more variable and can be disturbed significantly by motion artifacts. One way of tackling this challenge is the combined evaluation of multiple channels via sensor fusion. For robust and accurate sensor fusion, analyzing the influence of motion on different modalities is crucial. In this work, a multimodal sensor setup integrated into an armchair is presented that combines capacitively coupled electrocardiography, reflective photoplethysmography, two high-frequency impedance sensors and two types of ballistocardiography sensors. To quantify motion artifacts, a motion protocol performed by healthy volunteers is recorded with a motion capture system, and reference sensors perform cardiorespiratory monitoring. The shape-based signal-to-noise ratio SNR S is introduced and used to quantify the effect on motion on different sensing modalities. Based on this analysis, an optimal combination of sensors and fusion methodology is developed and evaluated. Using the proposed approach, beat-to-beat heart-rate is estimated with a coverage of 99.5% and a mean absolute error of 7.9 ms on 425 min of data from seven volunteers in a proof-of-concept measurement scenario.
Sparse Coding of Natural Human Motion Yields Eigenmotions Consistent Across People
NASA Astrophysics Data System (ADS)
Thomik, Andreas; Faisal, A. Aldo
2015-03-01
Providing a precise mathematical description of the structure of natural human movement is a challenging problem. We use a data-driven approach to seek a generative model of movement capturing the underlying simplicity of spatial and temporal structure of behaviour observed in daily life. In perception, the analysis of natural scenes has shown that sparse codes of such scenes are information theoretic efficient descriptors with direct neuronal correlates. Translating from perception to action, we identify a generative model of movement generation by the human motor system. Using wearable full-hand motion capture, we measure the digit movement of the human hand in daily life. We learn a dictionary of ``eigenmotions'' which we use for sparse encoding of the movement data. We show that the dictionaries are generally well preserved across subjects with small deviations accounting for individuality of the person and variability in tasks. Further, the dictionary elements represent motions which can naturally describe hand movements. Our findings suggest the motor system can compose complex movement behaviours out of the spatially and temporally sparse activation of ``eigenmotion'' neurons, and is consistent with data on grasp-type specificity of specialised neurons in the premotor cortex. Andreas is supported by the Luxemburg Research Fund (1229297).
Enhancement of vortex induced forces and motion through surface roughness control
Bernitsas, Michael M [Saline, MI; Raghavan, Kamaldev [Houston, TX
2011-11-01
Roughness is added to the surface of a bluff body in a relative motion with respect to a fluid. The amount, size, and distribution of roughness on the body surface is controlled passively or actively to modify the flow around the body and subsequently the Vortex Induced Forces and Motion (VIFM). The added roughness, when designed and implemented appropriately, affects in a predetermined way the boundary layer, the separation of the boundary layer, the level of turbulence, the wake, the drag and lift forces, and consequently the Vortex Induced Motion (VIM), and the fluid-structure interaction. The goal of surface roughness control is to increase Vortex Induced Forces and Motion. Enhancement is needed in such applications as harnessing of clean and renewable energy from ocean/river currents using the ocean energy converter VIVACE (Vortex Induced Vibration for Aquatic Clean Energy).
de Oliveira, Riza Rute; do Nascimento, Simony Lira; Derchain, Sophie F M; Sarian, Luís Otávio
2013-05-01
Mastectomy negatively affects scapulothoracic and glenohumeral kinematics. Breast reconstructive methods such as the latissimus dorsi flap can result in anatomical modifications that may in theory further affect the shoulder apparatus. The purpose of this study was to examine the effects of latissimus dorsi flap reconstruction on the recovery of shoulder motion and other postsurgical problems during the first year after mastectomy. This was a prospective cohort study of 104 consecutive mastectomies (47 with immediate latissimus dorsi flaps). Shoulder range of motion was assessed before and at 1, 3, 6, and 12 months after surgery. Pain, tissue adhesion, scar enlargement, and web syndrome were assessed during follow-up. There was a 30 percent decrease of shoulder range of motion 1 month after surgery, with gradual recovery over time. However, mean abduction and flexion capacities did not reach baseline levels and were on average 5 to 10 percent lower than baseline, even after 1 year. Over time, the latissimus dorsi flap was not associated with restriction of flexion or abduction. Scar enlargement (at the first month, p = 0.009) and tissue adhesion (at month 12, p = 0.032) were significantly less common in the latissimus dorsi flap group. The authors' study clearly suggests that the additional anatomical manipulation required for the latissimus dorsi flap procedure does not further affect shoulder kinematics and is associated with a lower incidence of tissue adhesion. Therapeutic, II.
The effect of mild motion sickness and sopite syndrome on multitasking cognitive performance.
Matsangas, Panagiotis; McCauley, Michael E; Becker, William
2014-09-01
In this study, we investigated the effects of mild motion sickness and sopite syndrome on multitasking cognitive performance. Despite knowledge on general motion sickness, little is known about the effect of motion sickness and sopite syndrome on multitasking cognitive performance. Specifically, there is a gap in existing knowledge in the gray area of mild motion sickness. Fifty-one healthy individuals performed a multitasking battery. Three independent groups of participants were exposed to two experimental sessions. Two groups received motion only in the first or the second session, whereas the control group did not receive motion. Measurements of motion sickness, sopite syndrome, alertness, and performance were collected during the experiment Only during the second session, motion sickness and sopite syndrome had a significant negative association with cognitive performance. Significant performance differences between symptomatic and asymptomatic participants in the second session were identified in composite (9.43%), memory (31.7%), and arithmetic (14.7%) task scores. The results suggest that performance retention between sessions was not affected by mild motion sickness. Multitasking cognitive performance declined even when motion sickness and soporific symptoms were mild. The results also show an order effect. We postulate that the differential effect of session on the association between symptomatology and multitasking performance may be related to the attentional resources allocated to performing the multiple tasks. Results suggest an inverse relationship between motion sickness effects on performance and the cognitive effort focused on performing a task. Even mild motion sickness has potential implications for multitasking operational performance.
Experience affects the use of ego-motion signals during 3D shape perception.
Jain, Anshul; Backus, Benjamin T
2010-12-29
Experience has long-term effects on perceptual appearance (Q. Haijiang, J. A. Saunders, R. W. Stone, & B. T. Backus, 2006). We asked whether experience affects the appearance of structure-from-motion stimuli when the optic flow is caused by observer ego-motion. Optic flow is an ambiguous depth cue: a rotating object and its oppositely rotating, depth-inverted dual generate similar flow. However, the visual system exploits ego-motion signals to prefer the percept of an object that is stationary over one that rotates (M. Wexler, F. Panerai, I. Lamouret, & J. Droulez, 2001). We replicated this finding and asked whether this preference for stationarity, the "stationarity prior," is modulated by experience. During training, two groups of observers were exposed to objects with identical flow, but that were either stationary or moving as determined by other cues. The training caused identical test stimuli to be seen preferentially as stationary or moving by the two groups, respectively. We then asked whether different priors can exist independently at different locations in the visual field. Observers were trained to see objects either as stationary or as moving at two different locations. Observers' stationarity bias at the two respective locations was modulated in the directions consistent with training. Thus, the utilization of extraretinal ego-motion signals for disambiguating optic flow signals can be updated as the result of experience, consistent with the updating of a Bayesian prior for stationarity.
NASA Astrophysics Data System (ADS)
Graizer, V.
2012-12-01
The MW 5.8 Mineral, Virginia earthquake was recorded at a relatively short epicentral distance of about 18 km at the North Anna Nuclear Power Plant (NPP) by the SMA-3 magnetic tape digital accelerographs installed inside the plant's containment at the foundation and deck levels. The North Anna NPP is operated by the Virginia Electric and Power Company (VEPCO) and has two pressurized water reactors (PWR) units that began operation in 1978 and 1980, respectively. Following the earthquake, both units were safely shutdown. The strong-motion records were processed to get velocity, displacement, Fourier and 5% damped response spectra. The basemat record demonstrated relatively high amplitudes of acceleration of 0.26 g and velocity of 13.8 cm/sec with a relatively short duration of strong motion of 2-3 sec. Recorded 5% damped Response Spectra exceed Design Basis Earthquake for the existing Units 1 and 2, while comprehensive plant inspections performed by VEPCO and U.S. Nuclear Regulatory Commission have concluded that the damage to the plant was minimal not affecting any structures and equipment significant to plant operation. This can be explained in part by short duration of the earthquake ground motion at the plant. The North Anna NPP did not have free-field strong motion instrumentation at the time of the earthquake. Since the containment is founded on rock there is a tendency to consider basemat record as an approximation of the free-field recording. However, comparisons of deck and basemat records demonstrate that the basemat recording is also affected by structural resonance frequencies higher than 3 Hz. Structural resonances in the frequency range of 3-4 Hz can at least partially explain significant exceedance of observed motions relative to ground motion calculated using ground motion prediction equations.cceleration, velocity and displacement at the North Anna NPP basemat level. Amplitudes of acceleration, velocity and displacement at basemat and deck levels
Ma, Yingliang; Paterson, Helena M; Pollick, Frank E
2006-02-01
We present the methods that were used in capturing a library of human movements for use in computer-animated displays of human movement. The library is an attempt to systematically tap into and represent the wide range of personal properties, such as identity, gender, and emotion, that are available in a person's movements. The movements from a total of 30 nonprofessional actors (15 of them female) were captured while they performed walking, knocking, lifting, and throwing actions, as well as their combination in angry, happy, neutral, and sad affective styles. From the raw motion capture data, a library of 4,080 movements was obtained, using techniques based on Character Studio (plug-ins for 3D Studio MAX, AutoDesk, Inc.), MATLAB The MathWorks, Inc.), or a combination of these two. For the knocking, lifting, and throwing actions, 10 repetitions of the simple action unit were obtained for each affect, and for the other actions, two longer movement recordings were obtained for each affect. We discuss the potential use of the library for computational and behavioral analyses of movement variability, of human character animation, and of how gender, emotion, and identity are encoded and decoded from human movement.
Jaeger, Gayle H; Wosar, Marc A; Marcellin-Little, Denis J; Lascelles, B Duncan X
2005-08-15
To describe placement of hinged transarticular external fixation (HTEF) frames and evaluate their ability to protect the primary repair of unstable joints while allowing joint mobility in dogs and cats. Retrospective study. 8 cats and 6 dogs. HTEF frames were composed of metal or epoxy connecting rods and a hinge. Measurements of range of motion of affected and contralateral joints and radiographs were made after fixator application and removal. 9 animals (4 cats and 5 dogs) had tarsal and 5 (4 cats and 1 dog) had stifle joint injuries. Treatment duration ranged from 45 to 100 days (median, 57 days). Ranges of motion in affected stifle and tarsal joints were 57% and 72% of control while HTEF was in place and 79% and 84% of control after frame removal. Complications were encountered in 3 cats and 2 dogs and included breakage of pins and connecting rods, hinge loosening, and failure at the hinge-epoxy interface. HTEF in animals with traumatic joint instability provided adjunctive joint stabilization during healing and protection of the primary repair and maintained joint motion during healing, resulting in early weight bearing of the affected limb.
Gaidhani, Apoorva; Moon, Kee S.; Ozturk, Yusuf; Lee, Sung Q.; Youm, Woosub
2017-01-01
Respiratory activity is an essential vital sign of life that can indicate changes in typical breathing patterns and irregular body functions such as asthma and panic attacks. Many times, there is a need to monitor breathing activity while performing day-to-day functions such as standing, bending, trunk stretching or during yoga exercises. A single IMU (inertial measurement unit) can be used in measuring respiratory motion; however, breathing motion data may be influenced by a body trunk movement that occurs while recording respiratory activity. This research employs a pair of wireless, wearable IMU sensors custom-made by the Department of Electrical Engineering at San Diego State University. After appropriate sensor placement for data collection, this research applies principles of robotics, using the Denavit-Hartenberg convention, to extract relative angular motion between the two sensors. One of the obtained relative joint angles in the “Sagittal” plane predominantly yields respiratory activity. An improvised version of the proposed method and wearable, wireless sensors can be suitable to extract respiratory information while performing sports or exercises, as they do not restrict body motion or the choice of location to gather data. PMID:29258214
Representation of particle motion in the auditory midbrain of a developing anuran.
Simmons, Andrea Megela
2015-07-01
In bullfrog tadpoles, a "deaf period" of lessened responsiveness to the pressure component of sounds, evident during the end of the late larval period, has been identified in the auditory midbrain. But coding of underwater particle motion in the vestibular medulla remains stable over all of larval development, with no evidence of a "deaf period." Neural coding of particle motion in the auditory midbrain was assessed to determine if a "deaf period" for this mode of stimulation exists in this brain area in spite of its absence from the vestibular medulla. Recording sites throughout the developing laminar and medial principal nuclei show relatively stable thresholds to z-axis particle motion, up until the "deaf period." Thresholds then begin to increase from this point up through the rest of metamorphic climax, and significantly fewer responsive sites can be located. The representation of particle motion in the auditory midbrain is less robust during later compared to earlier larval stages, overlapping with but also extending beyond the restricted "deaf period" for pressure stimulation. The decreased functional representation of particle motion in the auditory midbrain throughout metamorphic climax may reflect ongoing neural reorganization required to mediate the transition from underwater to amphibious life.
Knowledge on Accelerated Motion as Measured by Implicit and Explicit Tasks in 5 to 16 Year Olds
ERIC Educational Resources Information Center
Ebersbach, Mirjam; Van Dooren, Wim; Verschaffel, Lieven
2011-01-01
The present study aimed at investigating children's and adolescents' understanding of constant and accelerated motions. The main objectives were (1) to investigate whether different task formats would affect the performance and (2) to track developmental changes in this domain. Five to 16 year olds (N = 157) predicted the distances of a moving…
ERIC Educational Resources Information Center
Johnson, Kerri L.; McKay, Lawrie S.; Pollick, Frank E.
2011-01-01
Gender stereotypes have been implicated in sex-typed perceptions of facial emotion. Such interpretations were recently called into question because facial cues of emotion are confounded with sexually dimorphic facial cues. Here we examine the role of visual cues and gender stereotypes in perceptions of biological motion displays, thus overcoming…
The Effective Mass of a Ball in the Air
ERIC Educational Resources Information Center
Messer, J.; Pantaleone, J.
2010-01-01
The air surrounding a projectile affects the projectile's motion in three very different ways: the drag force, the buoyant force, and the added mass. The added mass is an increase in the projectile's inertia from the motion of the air around it. Here we experimentally measure the added mass of a spherical projectile in air. The results agree well…
Stimulus and response conflict processing during perceptual decision making.
Wendelken, Carter; Ditterich, Jochen; Bunge, Silvia A; Carter, Cameron S
2009-12-01
Encoding and dealing with conflicting information is essential for successful decision making in a complex environment. In the present fMRI study, stimulus conflict and response conflict are contrasted in the context of a perceptual decision-making dot-motion discrimination task. Stimulus conflict was manipulated by varying dot-motion coherence along task-relevant and task-irrelevant dimensions. Response conflict was manipulated by varying whether or not competing stimulus dimensions provided evidence for the same or different responses. The right inferior frontal gyrus was involved specifically in the resolution of stimulus conflict, whereas the dorsal anterior cingulate cortex was shown to be sensitive to response conflict. Additionally, two regions that have been linked to perceptual decision making with dot-motion stimuli in monkey physiology studies were differentially engaged by stimulus conflict and response conflict. The middle temporal area, previously linked to processing of motion, was strongly affected by the presence of stimulus conflict. On the other hand, the superior parietal lobe, previously associated with accumulation of evidence for a response, was affected by the presence of response conflict. These results shed light on the neural mechanisms that support decision making in the presence of conflict, a cognitive operation fundamental to both basic survival and high-level cognition.
Postural and Spatial Orientation Driven by Virtual Reality
Keshner, Emily A.; Kenyon, Robert V.
2009-01-01
Orientation in space is a perceptual variable intimately related to postural orientation that relies on visual and vestibular signals to correctly identify our position relative to vertical. We have combined a virtual environment with motion of a posture platform to produce visual-vestibular conditions that allow us to explore how motion of the visual environment may affect perception of vertical and, consequently, affect postural stabilizing responses. In order to involve a higher level perceptual process, we needed to create a visual environment that was immersive. We did this by developing visual scenes that possess contextual information using color, texture, and 3-dimensional structures. Update latency of the visual scene was close to physiological latencies of the vestibulo-ocular reflex. Using this system we found that even when healthy young adults stand and walk on a stable support surface, they are unable to ignore wide field of view visual motion and they adapt their postural orientation to the parameters of the visual motion. Balance training within our environment elicited measurable rehabilitation outcomes. Thus we believe that virtual environments can serve as a clinical tool for evaluation and training of movement in situations that closely reflect conditions found in the physical world. PMID:19592796
Maziero, Danilo; Velasco, Tonicarlo R; Hunt, Nigel; Payne, Edwin; Lemieux, Louis; Salmon, Carlos E G; Carmichael, David W
2016-09-01
The simultaneous acquisition of electroencephalography and functional magnetic resonance imaging (EEG-fMRI) is a multimodal technique extensively applied for mapping the human brain. However, the quality of EEG data obtained within the MRI environment is strongly affected by subject motion due to the induction of voltages in addition to artefacts caused by the scanning gradients and the heartbeat. This has limited its application in populations such as paediatric patients or to study epileptic seizure onset. Recent work has used a Moiré-phase grating and a MR-compatible camera to prospectively update image acquisition and improve fMRI quality (prospective motion correction: PMC). In this study, we use this technology to retrospectively reduce the spurious voltages induced by motion in the EEG data acquired inside the MRI scanner, with and without fMRI acquisitions. This was achieved by modelling induced voltages from the tracking system motion parameters; position and angles, their first derivative (velocities) and the velocity squared. This model was used to remove the voltages related to the detected motion via a linear regression. Since EEG quality during fMRI relies on a temporally stable gradient artefact (GA) template (calculated from averaging EEG epochs matched to scan volume or slice acquisition), this was evaluated in sessions both with and without motion contamination, and with and without PMC. We demonstrate that our approach is capable of significantly reducing motion-related artefact with a magnitude of up to 10mm of translation, 6° of rotation and velocities of 50mm/s, while preserving physiological information. We also demonstrate that the EEG-GA variance is not increased by the gradient direction changes associated with PMC. Provided a scan slice-based GA template is used (rather than a scan volume GA template) we demonstrate that EEG variance during motion can be supressed towards levels found when subjects are still. In summary, we show that PMC can be used to dramatically improve EEG quality during large amplitude movements, while benefiting from previously reported improvements in fMRI quality, and does not affect EEG data quality in the absence of large amplitude movements. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Principles for selecting earthquake motions in engineering design of large dams
Krinitzsky, E.L.; Marcuson, William F.
1983-01-01
This report gives a synopsis of the various tools and techniques used in selecting earthquake ground motion parameters for large dams. It presents 18 charts giving newly developed relations for acceleration, velocity, and duration versus site earthquake intensity for near- and far-field hard and soft sites and earthquakes having magnitudes above and below 7. The material for this report is based on procedures developed at the Waterways Experiment Station. Although these procedures are suggested primarily for large dams, they may also be applicable for other facilities. Because no standard procedure exists for selecting earthquake motions in engineering design of large dams, a number of precautions are presented to guide users. The selection of earthquake motions is dependent on which one of two types of engineering analyses are performed. A pseudostatic analysis uses a coefficient usually obtained from an appropriate contour map; whereas, a dynamic analysis uses either accelerograms assigned to a site or specified respunse spectra. Each type of analysis requires significantly different input motions. All selections of design motions must allow for the lack of representative strong motion records, especially near-field motions from earthquakes of magnitude 7 and greater, as well as an enormous spread in the available data. Limited data must be projected and its spread bracketed in order to fill in the gaps and to assure that there will be no surprises. Because each site may have differing special characteristics in its geology, seismic history, attenuation, recurrence, interpreted maximum events, etc., as integrated approach gives best results. Each part of the site investigation requires a number of decisions. In some cases, the decision to use a 'least ork' approach may be suitable, simply assuming the worst of several possibilities and testing for it. Because there are no standard procedures to follow, multiple approaches are useful. For example, peak motions at a site may be obtained from several methods that involve magnitude of earthquake, distance from source, and corresponding motions; or, alternately, peak motions may be assigned from other correlations based on earthquake intensity. Various interpretations exist to account for duration, recurrence, effects of site conditions, etc. Comparison of the various interpretations can be very useful. Probabilities can be assigned; however, they can present very serious problems unless appropriate care is taken when data are extrapolated beyond their data base. In making deterministic judgments, probabilistic data can provide useful guidance in estimating the uncertainties of the decision. The selection of a design ground motion for large dams is based in the end on subjective judgments which should depend, to an important extent, on the consequences of failure. Usually, use of a design value of ground motion representing a mean plus one standard deviation of possible variation in the mean of the data puts one in a conservative position. If failure presents no hazard to life, lower values of design ground motion may be justified, providing there are cost benefits and the risk is acceptable to the owner. Where a large hazard to life exists (i.e., a dam above an urbanized area) one may wish to use values of design ground motion that approximate the very worst case. The selection of a design ground motion must be appropriate for its particular set of circumstances.
How Wearable Sensors Can Support Parkinson's Disease Diagnosis and Treatment: A Systematic Review
Rovini, Erika; Maremmani, Carlo; Cavallo, Filippo
2017-01-01
Background: Parkinson's disease (PD) is a common and disabling pathology that is characterized by both motor and non-motor symptoms and affects millions of people worldwide. The disease significantly affects quality of life of those affected. Many works in literature discuss the effects of the disease. The most promising trends involve sensor devices, which are low cost, low power, unobtrusive, and accurate in the measurements, for monitoring and managing the pathology. Objectives: This review focuses on wearable devices for PD applications and identifies five main fields: early diagnosis, tremor, body motion analysis, motor fluctuations (ON–OFF phases), and home and long-term monitoring. The concept is to obtain an overview of the pathology at each stage of development, from the beginning of the disease to consider early symptoms, during disease progression with analysis of the most common disorders, and including management of the most complicated situations (i.e., motor fluctuations and long-term remote monitoring). Data sources: The research was conducted within three databases: IEEE Xplore®, Science Direct®, and PubMed Central®, between January 2006 and December 2016. Study eligibility criteria: Since 1,429 articles were found, accurate definition of the exclusion criteria and selection strategy allowed identification of the most relevant papers. Results: Finally, 136 papers were fully evaluated and included in this review, allowing a wide overview of wearable devices for the management of Parkinson's disease. PMID:29056899
How Wearable Sensors Can Support Parkinson's Disease Diagnosis and Treatment: A Systematic Review.
Rovini, Erika; Maremmani, Carlo; Cavallo, Filippo
2017-01-01
Background: Parkinson's disease (PD) is a common and disabling pathology that is characterized by both motor and non-motor symptoms and affects millions of people worldwide. The disease significantly affects quality of life of those affected. Many works in literature discuss the effects of the disease. The most promising trends involve sensor devices, which are low cost, low power, unobtrusive, and accurate in the measurements, for monitoring and managing the pathology. This review focuses on wearable devices for PD applications and identifies five main fields: early diagnosis, tremor, body motion analysis, motor fluctuations (ON-OFF phases), and home and long-term monitoring. The concept is to obtain an overview of the pathology at each stage of development, from the beginning of the disease to consider early symptoms, during disease progression with analysis of the most common disorders, and including management of the most complicated situations (i.e., motor fluctuations and long-term remote monitoring). The research was conducted within three databases: IEEE Xplore®, Science Direct®, and PubMed Central®, between January 2006 and December 2016. Since 1,429 articles were found, accurate definition of the exclusion criteria and selection strategy allowed identification of the most relevant papers. Finally, 136 papers were fully evaluated and included in this review, allowing a wide overview of wearable devices for the management of Parkinson's disease.
The equations of motion for moist atmospheric air
NASA Astrophysics Data System (ADS)
Makarieva, Anastassia M.; Gorshkov, Victor G.; Nefiodov, Andrei V.; Sheil, Douglas; Nobre, Antonio Donato; Bunyard, Peter; Nobre, Paulo; Li, Bai-Lian
2017-07-01
How phase transitions affect the motion of moist atmospheric air remains controversial. In the early 2000s two distinct differential equations of motion were proposed. Besides their contrasting formulations for the acceleration of condensate, the equations differ concerning the presence/absence of a term equal to the rate of phase transitions multiplied by the difference in velocity between condensate and air. This term was interpreted in the literature as the "reactive motion" associated with condensation. The reasoning behind this reactive motion was that when water vapor condenses and droplets begin to fall the remaining gas must move upward to conserve momentum. Here we show that the two contrasting formulations imply distinct assumptions about how gaseous air and condensate particles interact. We show that these assumptions cannot be simultaneously applicable to condensation and evaporation. Reactive motion leading to an upward acceleration of air during condensation does not exist. The reactive motion term can be justified for evaporation only; it describes the downward acceleration of air. We emphasize the difference between the equations of motion (i.e., equations constraining velocity) and those constraining momentum (i.e., equations of motion and continuity combined). We show that owing to the imprecise nature of the continuity equations, consideration of total momentum can be misleading and that this led to the reactive motion controversy. Finally, we provide a revised and generally applicable equation for the motion of moist air.
Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer.
Nehmeh, S A; Erdi, Y E; Ling, C C; Rosenzweig, K E; Squire, O D; Braban, L E; Ford, E; Sidhu, K; Mageras, G S; Larson, S M; Humm, J L
2002-03-01
Positron emission tomography (PET) has shown an increase in both sensitivity and specificity over computed tomography (CT) in lung cancer. However, motion artifacts in the 18F fluorodioxydoglucose (FDG) PET images caused by respiration persists to be an important factor in degrading PET image quality and quantification. Motion artifacts lead to two major effects: First, it affects the accuracy of quantitation, producing a reduction of the measured standard uptake value (SUV). Second, the apparent lesion volume is overestimated. Both impact upon the usage of PET images for radiation treatment planning. The first affects the visibility, or contrast, of the lesion. The second results in an increase in the planning target volume, and consequently a greater radiation dose to the normal tissues. One way to compensate for this effect is by applying a multiple-frame capture technique. The PET data are then acquired in synchronization with the respiratory motion. Reduction in smearing due to gating was investigated in both phantoms and patient studies. Phantom studies showed a dependence of the reduction in smearing on the lesion size, the motion amplitude, and the number of bins used for data acquisition. These studies also showed an improvement in the target-to-background ratio, and a more accurate measurement of the SUV. When applied to one patient, respiratory gating showed a 28% reduction in the total lesion volume, and a 56.5% increase in the SUV. This study was conducted as a proof of principle that a gating technique can effectively reduce motion artifacts in PET image acquisition.
The portrayal of coma in contemporary motion pictures.
Wijdicks, Eelco F M; Wijdicks, Coen A
2006-05-09
Coma has been a theme of screenplays in motion pictures, but there is no information about its accuracy. The authors reviewed 30 movies from 1970 to 2004 with actors depicting prolonged coma. Accurate depiction of comatose patients was defined by appearance, the complexity of care, accurate cause of coma and probability of awakening, and appropriate compassionate discussion between the physician and family members. Twenty-two key scenes from 17 movies were rated for accuracy by a panel of neurointensivists and neuroscience nurses and then were shown to 72 nonmedical viewers. Accuracy of the scenes was assessed using a Likert Scale. Coma was most often caused by motor vehicle accidents or violence (63%). The time in a comatose state varied from days to 10 years. Awakening occurred in 18 of 30 motion pictures (60%). Awakening was sudden with cognition intact, even after prolonged time in a coma. Actors personified "Sleeping Beauty" (eyes closed, beautifully groomed). Physicians appeared as caricatures. Only two movies had a reasonable accurate representation (Dream Life of Angels and Reversal of Fortune). The majority of the surveyed viewers identified inaccuracy of representation of coma, awakenings, and conversations on the experience of being in a coma, except in 8 of the 22 scenes (36%). Twenty-eight of the 72 viewers (39%) could potentially allow these scenes to influence decisions in real life. Misrepresentation of coma and awakening was common in motion pictures and impacted on the public perception of coma. Neurologic advice regarding prolonged coma is needed.
An Open Architecture for Defense Virtual Environment Training Systems
2003-09-01
Additionally, in the process, preventing the loss of life is also an important result. VRTEs can provide needed training that might otherwise not be...training is directly valuable in mission accomplishment and in preventing loss of life. "One of the biggest problems in both the military and...simplified; unique bones motion offers lifelike bouncing and twisting. 43 o Complete skeletal and muscle control features. o Inverse Kinematics
Individualistic weight perception from motion on a slope
Zintus-art, K.; Shin, D.; Kambara, H.; Yoshimura, N.; Koike, Y.
2016-01-01
Perception of an object’s weight is linked to its form and motion. Studies have shown the relationship between weight perception and motion in horizontal and vertical environments to be universally identical across subjects during passive observation. Here we show a contradicting finding in that not all humans share the same motion-weight pairing. A virtual environment where participants control the steepness of a slope was used to investigate the relationship between sliding motion and weight perception. Our findings showed that distinct, albeit subjective, motion-weight relationships in perception could be identified for slope environments. These individualistic perceptions were found when changes in environmental parameters governing motion were introduced, specifically inclination and surface texture. Differences in environmental parameters, combined with individual factors such as experience, affected participants’ weight perception. This phenomenon may offer evidence of the central nervous system’s ability to choose and combine internal models based on information from the sensory system. The results also point toward the possibility of controlling human perception by presenting strong sensory cues to manipulate the mechanisms managing internal models. PMID:27174036
Application and assessment of a robust elastic motion correction algorithm to dynamic MRI.
Herrmann, K-H; Wurdinger, S; Fischer, D R; Krumbein, I; Schmitt, M; Hermosillo, G; Chaudhuri, K; Krishnan, A; Salganicoff, M; Kaiser, W A; Reichenbach, J R
2007-01-01
The purpose of this study was to assess the performance of a new motion correction algorithm. Twenty-five dynamic MR mammography (MRM) data sets and 25 contrast-enhanced three-dimensional peripheral MR angiographic (MRA) data sets which were affected by patient motion of varying severeness were selected retrospectively from routine examinations. Anonymized data were registered by a new experimental elastic motion correction algorithm. The algorithm works by computing a similarity measure for the two volumes that takes into account expected signal changes due to the presence of a contrast agent while penalizing other signal changes caused by patient motion. A conjugate gradient method is used to find the best possible set of motion parameters that maximizes the similarity measures across the entire volume. Images before and after correction were visually evaluated and scored by experienced radiologists with respect to reduction of motion, improvement of image quality, disappearance of existing lesions or creation of artifactual lesions. It was found that the correction improves image quality (76% for MRM and 96% for MRA) and diagnosability (60% for MRM and 96% for MRA).
Düzgün, İrem; Baltacı, Gül; Turgut, Elif; Atay, O Ahmet
2014-01-01
The aim of the study was to investigate the effects of the early initiation of passive and active range of motion exercises following arthroscopic rotator cuff repair. The study included 40 patients who underwent arthroscopic rotator cuff repair. Patients were quasi-randomly assigned into accelerated (ACCEL) protocol (n=19) and slow (SLOW) protocol (n=21) groups. Patients in both groups were treated with the same protocol. Active range of motion was begun at the 3rd week in the ACCEL group and the 6th week in the SLOW group. Range of motion was recorded at postoperative weeks 3, 5, 8, 12, and 24. While active range of motion for all measurements improved across weeks, there were no differences between groups, with the exception of active total elevation which was greater at all time point measurements in the ACCEL group (p<0.05). The early initiation of passive and gentle controlled active motion exercise following rotator cuff repairs does not appear to affect range of motion in the first 6 postoperative months.
Earthquakes: Risk, Detection, Warning, and Research
2010-01-14
which affect taller , multi-story buildings. Ground motion that affects shorter buildings of a few stories, called short-period seismic waves, is...places in a single fault, or jump between connected faults. Earthquakes that occur along the Sierra Madre fault in southern California, for example
Effect of a Near Fault on the Seismic Response of a Base-Isolated Structure with a Soft Storey
NASA Astrophysics Data System (ADS)
Athamnia, B.; Ounis, A.; Abdeddaim, M.
2017-12-01
This study focuses on the soft-storey behavior of RC structures with lead core rubber bearing (LRB) isolation systems under near and far-fault motions. Under near-fault ground motions, seismic isolation devices might perform poorly because of large isolator displacements caused by large velocity and displacement pulses associated with such strong motions. In this study, four different structural models have been designed to study the effect of soft-storey behavior under near-fault and far-fault motions. The seismic analysis for isolated reinforced concrete buildings is carried out using a nonlinear time history analysis method. Inter-story drifts, absolute acceleration, displacement, base shear forces, hysteretic loops and the distribution of plastic hinges are examined as a result of the analysis. These results show that the performance of a base isolated RC structure is more affected by increasing the height of a story under nearfault motion than under far-fault motion.
Defining the computational structure of the motion detector in Drosophila.
Clark, Damon A; Bursztyn, Limor; Horowitz, Mark A; Schnitzer, Mark J; Clandinin, Thomas R
2011-06-23
Many animals rely on visual motion detection for survival. Motion information is extracted from spatiotemporal intensity patterns on the retina, a paradigmatic neural computation. A phenomenological model, the Hassenstein-Reichardt correlator (HRC), relates visual inputs to neural activity and behavioral responses to motion, but the circuits that implement this computation remain unknown. By using cell-type specific genetic silencing, minimal motion stimuli, and in vivo calcium imaging, we examine two critical HRC inputs. These two pathways respond preferentially to light and dark moving edges. We demonstrate that these pathways perform overlapping but complementary subsets of the computations underlying the HRC. A numerical model implementing differential weighting of these operations displays the observed edge preferences. Intriguingly, these pathways are distinguished by their sensitivities to a stimulus correlation that corresponds to an illusory percept, "reverse phi," that affects many species. Thus, this computational architecture may be widely used to achieve edge selectivity in motion detection. Copyright © 2011 Elsevier Inc. All rights reserved.
Structure preserving clustering-object tracking via subgroup motion pattern segmentation
NASA Astrophysics Data System (ADS)
Fan, Zheyi; Zhu, Yixuan; Jiang, Jiao; Weng, Shuqin; Liu, Zhiwen
2018-01-01
Tracking clustering objects with similar appearances simultaneously in collective scenes is a challenging task in the field of collective motion analysis. Recent work on clustering-object tracking often suffers from poor tracking accuracy and terrible real-time performance due to the neglect or the misjudgment of the motion differences among objects. To address this problem, we propose a subgroup motion pattern segmentation framework based on a multilayer clustering structure and establish spatial constraints only among objects in the same subgroup, which entails having consistent motion direction and close spatial position. In addition, the subgroup segmentation results are updated dynamically because crowd motion patterns are changeable and affected by objects' destinations and scene structures. The spatial structure information combined with the appearance similarity information is used in the structure preserving object tracking framework to track objects. Extensive experiments conducted on several datasets containing multiple real-world crowd scenes validate the accuracy and the robustness of the presented algorithm for tracking objects in collective scenes.
Observing the overall rocking motion of a protein in a crystal
NASA Astrophysics Data System (ADS)
Ma, Peixiang; Xue, Yi; Coquelle, Nicolas; Haller, Jens D.; Yuwen, Tairan; Ayala, Isabel; Mikhailovskii, Oleg; Willbold, Dieter; Colletier, Jacques-Philippe; Skrynnikov, Nikolai R.; Schanda, Paul
2015-10-01
The large majority of three-dimensional structures of biological macromolecules have been determined by X-ray diffraction of crystalline samples. High-resolution structure determination crucially depends on the homogeneity of the protein crystal. Overall `rocking' motion of molecules in the crystal is expected to influence diffraction quality, and such motion may therefore affect the process of solving crystal structures. Yet, so far overall molecular motion has not directly been observed in protein crystals, and the timescale of such dynamics remains unclear. Here we use solid-state NMR, X-ray diffraction methods and μs-long molecular dynamics simulations to directly characterize the rigid-body motion of a protein in different crystal forms. For ubiquitin crystals investigated in this study we determine the range of possible correlation times of rocking motion, 0.1-100 μs. The amplitude of rocking varies from one crystal form to another and is correlated with the resolution obtainable in X-ray diffraction experiments.
Helicopter Flight Simulation Motion Platform Requirements
NASA Technical Reports Server (NTRS)
Schroeder, Jeffery Allyn
1999-01-01
To determine motion fidelity requirements, a series of piloted simulations was performed. Several key results were found. First, lateral and vertical translational platform cues had significant effects on fidelity. Their presence improved performance and reduced pilot workload. Second, yaw and roll rotational platform cues were not as important as the translational platform cues. In particular, the yaw rotational motion platform cue did not appear at all useful in improving performance or reducing workload. Third, when the lateral translational platform cue was combined with visual yaw rotational cues, pilots believed the platform was rotating when it was not. Thus, simulator systems can be made more efficient by proper combination of platform and visual cues. Fourth, motion fidelity specifications were revised that now provide simulator users with a better prediction of motion fidelity based upon the frequency responses of their motion control laws. Fifth, vertical platform motion affected pilot estimates of steady-state altitude during altitude repositioning. Finally, the combined results led to a general method for configuring helicopter motion systems and for developing simulator tasks that more likely represent actual flight. The overall results can serve as a guide to future simulator designers and to today's operators.
Imaging a moving lung tumor with megavoltage cone beam computed tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gayou, Olivier, E-mail: ogayou@wpahs.org; Colonias, Athanasios
2015-05-15
Purpose: Respiratory motion may affect the accuracy of image guidance of radiation treatment of lung cancer. A cone beam computed tomography (CBCT) image spans several breathing cycles, resulting in a blurred object with a theoretical size equal to the sum of tumor size and breathing motion. However, several factors may affect this theoretical relationship. The objective of this study was to analyze the effect of tumor motion on megavoltage (MV)-CBCT images, by comparing target sizes on simulation and pretreatment images of a large cohort of lung cancer patients. Methods: Ninety-three MV-CBCT images from 17 patients were analyzed. Internal target volumesmore » were contoured on each MV-CBCT dataset [internal target volume (ITV{sub CB})]. Their extent in each dimension was compared to that of two volumes contoured on simulation 4-dimensional computed tomography (4D-CT) images: the combination of the tumor contours of each phase of the 4D-CT (ITV{sub 4D}) and the volume contoured on the average CT calculated from the 4D-CT phases (ITV{sub ave}). Tumor size and breathing amplitude were assessed by contouring the tumor on each CBCT raw projection where it could be unambiguously identified. The effect of breathing amplitude on the quality of the MV-CBCT image reconstruction was analyzed. Results: The mean differences between the sizes of ITV{sub CB} and ITV{sub 4D} were −1.6 ± 3.3 mm (p < 0.001), −2.4 ± 3.1 mm (p < 0.001), and −7.2 ± 5.3 mm (p < 0.001) in the anterior/posterior (AP), left/right (LR), and superior/inferior (SI) directions, respectively, showing that MV-CBCT underestimates the full target size. The corresponding mean differences between ITV{sub CB} and ITV{sub ave} were 0.3 ± 2.6 mm (p = 0.307), 0.0 ± 2.4 mm (p = 0.86), and −4.0 ± 4.3 mm (p < 0.001), indicating that the average CT image is more representative of what is visible on MV-CBCT in the AP and LR directions. In the SI directions, differences between ITV{sub CB} and ITV{sub ave} could be separated into two groups based on tumor motion: −3.2 ± 3.2 mm for tumor motion less than 15 mm and −10.9 ± 6.3 mm for tumor motion greater than 15 mm. Deviations of measured target extents from their theoretical values derived from tumor size and motion were correlated with motion amplitude similarly for both MV-CBCT and average CT images, suggesting that the two images were subject to similar motion artifacts for motion less than 15 mm. Conclusions: MV-CBCT images are affected by tumor motion and tend to under-represent the full target volume. For tumor motion up to 15 mm, the volume contoured on average CT is comparable to that contoured on the MV-CBCT. Therefore, the average CT should be used in image registration for localization purposes, and the standard 5 mm PTV margin seems adequate. For tumor motion greater than 15 mm, an additional setup margin may need to be used to account for the increased uncertainty in tumor localization.« less
Four-Dimensional CT of the Diaphragm in Children: Initial Experience
2018-01-01
Objective To evaluate the technical feasibility of four-dimensional (4D) CT for the functional evaluation of the pediatric diaphragm. Materials and Methods In 22 consecutive children (median age 3.5 months, age range 3 days–3 years), 4D CT was performed to assess diaphragm motion. Diaphragm abnormalities were qualitatively evaluated and diaphragm motion was quantitatively measured on 4D CT. Lung density changes between peak inspiration and expiration were measured in the basal lung parenchyma. The diaphragm motions and lung density changes measured on 4D CT were compared between various diaphragm conditions. In 11 of the 22 children, chest sonography was available for comparison. Results Four-dimensional CT demonstrated normal diaphragm (n = 8), paralysis (n = 10), eventration (n = 3), and diffusely decreased motion (n = 1). Chest sonography demonstrated normal diaphragm (n = 2), paralysis (n = 6), eventration (n = 2), and right pleural effusion (n = 1). The sonographic findings were concordant with the 4D CT findings in 90.9% (10/11) of the patients. In diaphragm paralysis, the affected diaphragm motion was significantly decreased compared with the contralateral normal diaphragm motion (−1.1 ± 2.2 mm vs. 7.6 ± 3.8 mm, p = 0.005). The normal diaphragms showed significantly greater motion than the paralyzed diaphragms (4.5 ± 2.1 mm vs. −1.1 ± 2.2 mm, p < 0.0001), while the normal diaphragm motion was significantly smaller than the motion of the contralateral normal diaphragm in paralysis (4.5 ± 2.1 mm vs. 7.6 ± 3.8 mm, p = 0.01). Basal lung density change of the affected side was significantly smaller than that of the contralateral side in diaphragm paralysis (89 ± 73 Hounsfield units [HU] vs. 180 ± 71 HU, p = 0.03), while no significant differences were found between the normal diaphragms and the paralyzed diaphragms (136 ± 66 HU vs. 89 ± 73 HU, p = 0.1) or between the normal diaphragms and the contralateral normal diaphragms in paralysis (136 ± 66 HU vs. 180 ± 71 HU, p = 0.1). Conclusion The functional evaluation of the pediatric diaphragm is feasible with 4D CT in select children. PMID:29354007
Merging analytic and empirical GEO debris synchronization dynamics
NASA Astrophysics Data System (ADS)
Anderson, Paul V.; McKnight, Darren S.; Di Pentino, Frank; Schaub, Hanspeter
2016-09-01
The motion of abandoned satellites near the geostationary (GEO) region has been extensively studied, modeled, and compared to the motion of station-kept, operational satellites, providing insights into the evolution of uncontrolled orbits at GEO. Analytic developments produced a family of curves represented in the ascending node versus inclination space describing the long-term precession of the orbit plane at GEO, and forecasted the clustering of objects at the geopotential wells. However, recent investigations were undertaken to characterize apparent anomalistic behavior of GEO objects and classification of objects into related families. This paper provides a unifying summary of early bottom-up analytical theory with more recent top-down operational observations, highlighting the common linkage between these dimensions of GEO object behavior. This paper also identifies the relevance of these patterns of life tendencies for future operations at and near GEO, and discusses the long-term implications of these patterns of life for space situational awareness activities in this regime.
Human error identification for laparoscopic surgery: Development of a motion economy perspective.
Al-Hakim, Latif; Sevdalis, Nick; Maiping, Tanaphon; Watanachote, Damrongpan; Sengupta, Shomik; Dissaranan, Charuspong
2015-09-01
This study postulates that traditional human error identification techniques fail to consider motion economy principles and, accordingly, their applicability in operating theatres may be limited. This study addresses this gap in the literature with a dual aim. First, it identifies the principles of motion economy that suit the operative environment and second, it develops a new error mode taxonomy for human error identification techniques which recognises motion economy deficiencies affecting the performance of surgeons and predisposing them to errors. A total of 30 principles of motion economy were developed and categorised into five areas. A hierarchical task analysis was used to break down main tasks of a urological laparoscopic surgery (hand-assisted laparoscopic nephrectomy) to their elements and the new taxonomy was used to identify errors and their root causes resulting from violation of motion economy principles. The approach was prospectively tested in 12 observed laparoscopic surgeries performed by 5 experienced surgeons. A total of 86 errors were identified and linked to the motion economy deficiencies. Results indicate the developed methodology is promising. Our methodology allows error prevention in surgery and the developed set of motion economy principles could be useful for training surgeons on motion economy principles. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Visual gravitational motion and the vestibular system in humans
Lacquaniti, Francesco; Bosco, Gianfranco; Indovina, Iole; La Scaleia, Barbara; Maffei, Vincenzo; Moscatelli, Alessandro; Zago, Myrka
2013-01-01
The visual system is poorly sensitive to arbitrary accelerations, but accurately detects the effects of gravity on a target motion. Here we review behavioral and neuroimaging data about the neural mechanisms for dealing with object motion and egomotion under gravity. The results from several experiments show that the visual estimates of a target motion under gravity depend on the combination of a prior of gravity effects with on-line visual signals on target position and velocity. These estimates are affected by vestibular inputs, and are encoded in a visual-vestibular network whose core regions lie within or around the Sylvian fissure, and are represented by the posterior insula/retroinsula/temporo-parietal junction. This network responds both to target motions coherent with gravity and to vestibular caloric stimulation in human fMRI studies. Transient inactivation of the temporo-parietal junction selectively disrupts the interception of targets accelerated by gravity. PMID:24421761
Visual gravitational motion and the vestibular system in humans.
Lacquaniti, Francesco; Bosco, Gianfranco; Indovina, Iole; La Scaleia, Barbara; Maffei, Vincenzo; Moscatelli, Alessandro; Zago, Myrka
2013-12-26
The visual system is poorly sensitive to arbitrary accelerations, but accurately detects the effects of gravity on a target motion. Here we review behavioral and neuroimaging data about the neural mechanisms for dealing with object motion and egomotion under gravity. The results from several experiments show that the visual estimates of a target motion under gravity depend on the combination of a prior of gravity effects with on-line visual signals on target position and velocity. These estimates are affected by vestibular inputs, and are encoded in a visual-vestibular network whose core regions lie within or around the Sylvian fissure, and are represented by the posterior insula/retroinsula/temporo-parietal junction. This network responds both to target motions coherent with gravity and to vestibular caloric stimulation in human fMRI studies. Transient inactivation of the temporo-parietal junction selectively disrupts the interception of targets accelerated by gravity.
Space adaptation syndrome: multiple etiological factors and individual differences
NASA Technical Reports Server (NTRS)
Lackner, J. R.; DiZio, P.
1991-01-01
Space motion sickness is a significant operational concern in the American and Soviet space programs. Nearly 70% of all astronauts and cosmonauts are affected to some degree during their first several days of flight. It is now beginning to appear that space motion sickness like terrestrial motion sickness is the consequence of multiple etiological factors. As we come to understand basic mechanisms of spatial orientation and sensory-motor adaptation we can begin to predict etiological factors in different motion environments. Individuals vary greatly in the extent to which they are susceptible to these different factors. However, individuals seem to be relatively self-consistent in terms of their rates of adaptation to provocative stimulation and their retention of adaptation. Attempts to relate susceptibility to motion sickness during the microgravity phases of parabolic flight maneuvers to vestibular function under 1G and 0G test conditions are described.
Reduction of vortex induced forces and motion through surface roughness control
Bernitsas, Michael M; Raghavan, Kamaldev
2014-04-01
Roughness is added to the surface of a bluff body in a relative motion with respect to a fluid. The amount, size, and distribution of roughness on the body surface is controlled passively or actively to modify the flow around the body and subsequently the Vortex Induced Forces and Motion (VIFM). The added roughness, when designed and implemented appropriately, affects in a predetermined way the boundary layer, the separation of the boundary layer, the level of turbulence, the wake, the drag and lift forces, and consequently the Vortex Induced Motion (VIM), and the fluid-structure interaction. The goal of surface roughness control is to decrease/suppress Vortex Induced Forces and Motion. Suppression is required when fluid-structure interaction becomes destructive as in VIM of flexible cylinders or rigid cylinders on elastic support, such as underwater pipelines, marine risers, tubes in heat exchangers, nuclear fuel rods, cooling towers, SPAR offshore platforms.
Continuous quantum measurement and the quantum to classical transition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhattacharya, Tanmoy; Habib, Salman; Jacobs, Kurt
2003-04-01
While ultimately they are described by quantum mechanics, macroscopic mechanical systems are nevertheless observed to follow the trajectories predicted by classical mechanics. Hence, in the regime defining macroscopic physics, the trajectories of the correct classical motion must emerge from quantum mechanics, a process referred to as the quantum to classical transition. Extending previous work [Bhattacharya, Habib, and Jacobs, Phys. Rev. Lett. 85, 4852 (2000)], here we elucidate this transition in some detail, showing that once the measurement processes that affect all macroscopic systems are taken into account, quantum mechanics indeed predicts the emergence of classical motion. We derive inequalities thatmore » describe the parameter regime in which classical motion is obtained, and provide numerical examples. We also demonstrate two further important properties of the classical limit: first, that multiple observers all agree on the motion of an object, and second, that classical statistical inference may be used to correctly track the classical motion.« less
Research and implementation of group animation based on normal cloud model
NASA Astrophysics Data System (ADS)
Li, Min; Wei, Bin; Peng, Bao
2011-12-01
Group Animation is a difficult technology problem which always has not been solved in computer Animation technology, All current methods have their limitations. This paper put forward a method: the Motion Coordinate and Motion Speed of true fish group was collected as sample data, reverse cloud generator was designed and run, expectation, entropy and super entropy are gotten. Which are quantitative value of qualitative concept. These parameters are used as basis, forward cloud generator was designed and run, Motion Coordinate and Motion Speed of two-dimensional fish group animation are produced, And two spirit state variable about fish group : the feeling of hunger, the feeling of fear are designed. Experiment is used to simulated the motion state of fish Group Animation which is affected by internal cause and external cause above, The experiment shows that the Group Animation which is designed by this method has strong Realistic.
Gastrointestinal motility in space motion sickness
NASA Technical Reports Server (NTRS)
Thornton, William E.; Linder, Barry J.; Moore, Thomas P.; Pool, Sam L.
1987-01-01
Gastrointestinal symptoms in space motion sickness (SMS) are significantly different from those in ordinary motion sickness (MS). Recording and tabulation of sounds was the only technique that could be used as a measure of motility during spaceflight operations. There were 17 subjects, six unaffected by SMS, who made ambulatory recordings preflight and inflight. With one exception, all those affected had sharply reduced sounds, while those unaffected had increases or moderate reductions. The mechanism of vomiting in SMS appears to be secondary to this ileus, in contrast to vomiting in ordinary MS, where the emesis center is thought to be directly triggered by the vestibular system.
Electrogastrograms during motion sickness in fasted and fed subjects
NASA Technical Reports Server (NTRS)
Stewart, John J.; Wood, Mary J.; Wood, Charles D.
1989-01-01
Seven human volunteers were subjected to stressful Coriolis stimulation (rotating chair) either during the fasted state or following the ingestion of yogurt (6 oz). Subjects tested after yogurt reached a malaise-III (M-III) endpoint of motion sickness after significantly (p smaller than 0.01) fewer head movements than subjects tested in the fasted state. Surface electrogastrogram (EGG) recordings at M-III were similar for both dietary stats and consisted of a brief period of tachygastria, followed by a period of low-amplitude EGG waves. Ingestion of yogurt enhanced susceptibility to motion sickness but did not affect the associated pattern of EGG.
Note: Attenuation motion of acoustically levitated spherical rotor
NASA Astrophysics Data System (ADS)
Lü, P.; Hong, Z. Y.; Yin, J. F.; Yan, N.; Zhai, W.; Wang, H. P.
2016-11-01
Here we observe the attenuation motion of spherical rotors levitated by near-field acoustic radiation force and analyze the factors that affect the duration time of free rotation. It is found that the rotating speed of freely rotating rotor decreases exponentially with respect to time. The time constant of exponential attenuation motion depends mainly on the levitation height, the mass of rotor, and the depth of concave ultrasound emitter. Large levitation height, large mass of rotor, and small depth of concave emitter are beneficial to increase the time constant and hence extend the duration time of free rotation.
Note: Attenuation motion of acoustically levitated spherical rotor.
Lü, P; Hong, Z Y; Yin, J F; Yan, N; Zhai, W; Wang, H P
2016-11-01
Here we observe the attenuation motion of spherical rotors levitated by near-field acoustic radiation force and analyze the factors that affect the duration time of free rotation. It is found that the rotating speed of freely rotating rotor decreases exponentially with respect to time. The time constant of exponential attenuation motion depends mainly on the levitation height, the mass of rotor, and the depth of concave ultrasound emitter. Large levitation height, large mass of rotor, and small depth of concave emitter are beneficial to increase the time constant and hence extend the duration time of free rotation.
Human Factors Vehicle Displacement Analysis: Engineering In Motion
NASA Technical Reports Server (NTRS)
Atencio, Laura Ashley; Reynolds, David; Robertson, Clay
2010-01-01
While positioned on the launch pad at the Kennedy Space Center, tall stacked launch vehicles are exposed to the natural environment. Varying directional winds and vortex shedding causes the vehicle to sway in an oscillating motion. The Human Factors team recognizes that vehicle sway may hinder ground crew operation, impact the ground system designs, and ultimately affect launch availability . The objective of this study is to physically simulate predicted oscillation envelopes identified by analysis. and conduct a Human Factors Analysis to assess the ability to carry out essential Upper Stage (US) ground operator tasks based on predicted vehicle motion.
Motion coherence affects human perception and pursuit similarly.
Beutter, B R; Stone, L S
2000-01-01
Pursuit and perception both require accurate information about the motion of objects. Recovering the motion of objects by integrating the motion of their components is a difficult visual task. Successful integration produces coherent global object motion, while a failure to integrate leaves the incoherent local motions of the components unlinked. We compared the ability of perception and pursuit to perform motion integration by measuring direction judgments and the concomitant eye-movement responses to line-figure parallelograms moving behind stationary rectangular apertures. The apertures were constructed such that only the line segments corresponding to the parallelogram's sides were visible; thus, recovering global motion required the integration of the local segment motion. We investigated several potential motion-integration rules by using stimuli with different object, vector-average, and line-segment terminator-motion directions. We used an oculometric decision rule to directly compare direction discrimination for pursuit and perception. For visible apertures, the percept was a coherent object, and both the pursuit and perceptual performance were close to the object-motion prediction. For invisible apertures, the percept was incoherently moving segments, and both the pursuit and perceptual performance were close to the terminator-motion prediction. Furthermore, both psychometric and oculometric direction thresholds were much higher for invisible apertures than for visible apertures. We constructed a model in which both perception and pursuit are driven by a shared motion-processing stage, with perception having an additional input from an independent static-processing stage. Model simulations were consistent with our perceptual and oculomotor data. Based on these results, we propose the use of pursuit as an objective and continuous measure of perceptual coherence. Our results support the view that pursuit and perception share a common motion-integration stage, perhaps within areas MT or MST.
Motion coherence affects human perception and pursuit similarly
NASA Technical Reports Server (NTRS)
Beutter, B. R.; Stone, L. S.
2000-01-01
Pursuit and perception both require accurate information about the motion of objects. Recovering the motion of objects by integrating the motion of their components is a difficult visual task. Successful integration produces coherent global object motion, while a failure to integrate leaves the incoherent local motions of the components unlinked. We compared the ability of perception and pursuit to perform motion integration by measuring direction judgments and the concomitant eye-movement responses to line-figure parallelograms moving behind stationary rectangular apertures. The apertures were constructed such that only the line segments corresponding to the parallelogram's sides were visible; thus, recovering global motion required the integration of the local segment motion. We investigated several potential motion-integration rules by using stimuli with different object, vector-average, and line-segment terminator-motion directions. We used an oculometric decision rule to directly compare direction discrimination for pursuit and perception. For visible apertures, the percept was a coherent object, and both the pursuit and perceptual performance were close to the object-motion prediction. For invisible apertures, the percept was incoherently moving segments, and both the pursuit and perceptual performance were close to the terminator-motion prediction. Furthermore, both psychometric and oculometric direction thresholds were much higher for invisible apertures than for visible apertures. We constructed a model in which both perception and pursuit are driven by a shared motion-processing stage, with perception having an additional input from an independent static-processing stage. Model simulations were consistent with our perceptual and oculomotor data. Based on these results, we propose the use of pursuit as an objective and continuous measure of perceptual coherence. Our results support the view that pursuit and perception share a common motion-integration stage, perhaps within areas MT or MST.
Srikesavan, Cynthia Swarnalatha; Shay, Barbara; Robinson, David B; Szturm, Tony
2013-03-09
Significant restriction in the ability to participate in home, work and community life results from pain, fatigue, joint damage, stiffness and reduced joint range of motion and muscle strength in people with rheumatoid arthritis or osteoarthritis of the hand. With modest evidence on the therapeutic effectiveness of conventional hand exercises, a task-oriented training program via real life object manipulations has been developed for people with arthritis. An innovative, computer-based gaming platform that allows a broad range of common objects to be seamlessly transformed into therapeutic input devices through instrumentation with a motion-sense mouse has also been designed. Personalized objects are selected to target specific training goals such as graded finger mobility, strength, endurance or fine/gross dexterous functions. The movements and object manipulation tasks that replicate common situations in everyday living will then be used to control and play any computer game, making practice challenging and engaging. The ongoing study is a 6-week, single-center, parallel-group, equally allocated and assessor-blinded pilot randomized controlled trial. Thirty people with rheumatoid arthritis or osteoarthritis affecting the hand will be randomized to receive either conventional hand exercises or the task-oriented training. The purpose is to determine a preliminary estimation of therapeutic effectiveness and feasibility of the task-oriented training program. Performance based and self-reported hand function, and exercise compliance are the study outcomes. Changes in outcomes (pre to post intervention) within each group will be assessed by paired Student t test or Wilcoxon signed-rank test and between groups (control versus experimental) post intervention using unpaired Student t test or Mann-Whitney U test. The study findings will inform decisions on the feasibility, safety and completion rate and will also provide preliminary data on the treatment effects of the task-oriented training compared with conventional hand exercises in people with rheumatoid arthritis or osteoarthritis of the hand. ClinicalTrials.gov: NCT01635582.
ERIC Educational Resources Information Center
Ridgeway, Dori
The ways in which knowledge of mechanical motion is affected by contextual factors of assessment such as means of depiction (ranging from abstract to contextualized) and the effect of sequencing of contexts (from abstract to contextualized or contextualized to abstract) on students' display of knowledge were studied for 40 fifth graders in two…
Demonstrating the Potential for Dynamic Auditory Stimulation to Contribute to Motion Sickness
Keshavarz, Behrang; Hettinger, Lawrence J.; Kennedy, Robert S.; Campos, Jennifer L.
2014-01-01
Auditory cues can create the illusion of self-motion (vection) in the absence of visual or physical stimulation. The present study aimed to determine whether auditory cues alone can also elicit motion sickness and how auditory cues contribute to motion sickness when added to visual motion stimuli. Twenty participants were seated in front of a curved projection display and were exposed to a virtual scene that constantly rotated around the participant's vertical axis. The virtual scene contained either visual-only, auditory-only, or a combination of corresponding visual and auditory cues. All participants performed all three conditions in a counterbalanced order. Participants tilted their heads alternately towards the right or left shoulder in all conditions during stimulus exposure in order to create pseudo-Coriolis effects and to maximize the likelihood for motion sickness. Measurements of motion sickness (onset, severity), vection (latency, strength, duration), and postural steadiness (center of pressure) were recorded. Results showed that adding auditory cues to the visual stimuli did not, on average, affect motion sickness and postural steadiness, but it did reduce vection onset times and increased vection strength compared to pure visual or pure auditory stimulation. Eighteen of the 20 participants reported at least slight motion sickness in the two conditions including visual stimuli. More interestingly, six participants also reported slight motion sickness during pure auditory stimulation and two of the six participants stopped the pure auditory test session due to motion sickness. The present study is the first to demonstrate that motion sickness may be caused by pure auditory stimulation, which we refer to as “auditorily induced motion sickness”. PMID:24983752
A study of longitudinal tumor motion in helical tomotherapy using a cylindrical phantom
Klein, Michael; Gaede, Stewart
2013-01-01
Tumor motion during radiation treatment on a helical tomotherapy unit may create problems due to interplay with motion of the multileaf collimator, gantry rotation, and patient couch translation through the gantry. This study evaluated this interplay effect for typical clinical parameters using a cylindrical phantom consisting of 1386 diode detectors placed on a respiratory motion platform. All combinations of radiation field widths (1, 2.5, and 5 cm) and gantry rotation periods (16, 30, and 60 s) were considered for sinusoidal motions with a period of 4 s and amplitudes of 5, 6, 7, 8, 9, and 10 mm, as well as real patient breathing pattern. Gamma comparisons with 2% dose difference and 2 mm distance to agreement and dose profiles were used for evaluation. The required motion margins were determined for each set of parameters. The required margin size increased with decreasing field width and increasing tumor motion amplitude, but was not affected by rotation period. The plans with the smallest field width of 1 cm have required motion margins approximately equal to the amplitude of motion (±25%), while those with the largest field width of 5 cm had required motion margins approximately equal to 20% of the motion amplitude (±20%). For tumor motion amplitudes below 6 mm and field widths above 1 cm, the required additional motion margins were very small, at a maximum of 2.5 mm for sinusoidal breathing patterns and 1.2 mm for the real patient breathing pattern. PACS numbers: 87.55.km, 87.55.Qr, 87.56.Fc
Hotspot motion caused the Hawaiian-Emperor Bend and LLSVPs are not fixed
NASA Astrophysics Data System (ADS)
Tarduno, J. A.; Bono, R. K.
2017-12-01
Paleomagnetic study of volcanic rocks remains the gold standard on which to assess hotspot motion, true polar wander and plate motion recorded by oceanic plates. There is remarkable consistency between paleomagnetic results from basaltic lavas recovered by ocean drilling of the Emperor seamounts, and independent predictions of plate circuits. Both reveal greater than 40 mm/yr of southward hotspot motion; thus the dominant reason for the distinct bend morphology the Hawaiian-Emperor track is hotspot motion rather than plate motion. These findings provide the motivation for moving beyond hotspot fixity to understand mantle processes responsible for the observed motions. Global analyses as well as comparisons between the Hawaiian-Emperor and Louisville tracks indicate only a minor (if any) role for true polar wander. Two viable, non-mutually exclusive processes to explain the observed Hawaiian plume motion are: i. plume-ridge and ii plume-LLSVP interaction. Here we further explore these issues by paleomagnetic analyses of basalts from the Cenozoic Hawaiian chain and Late Cretaceous basalts of the southernmost Pacific Plate. The latter yield paleolatitudes consistent with those from the northern Pacific, indicating that long-standing non-dipole fields cannot have been large enough to affect conclusions on hotspot drift. Data from the former suggest some relative motions between the LLSVPs on tens-of-millions of year time scales, which probably record the continual reshaping of these provinces by plume motion in the lower mantle.
Unconscious Local Motion Alters Global Image Speed
Khuu, Sieu K.; Chung, Charles Y. L.; Lord, Stephanie; Pearson, Joel
2014-01-01
Accurate motion perception of self and object speed is crucial for successful interaction in the world. The context in which we make such speed judgments has a profound effect on their accuracy. Misperceptions of motion speed caused by the context can have drastic consequences in real world situations, but they also reveal much about the underlying mechanisms of motion perception. Here we show that motion signals suppressed from awareness can warp simultaneous conscious speed perception. In Experiment 1, we measured global speed discrimination thresholds using an annulus of 8 local Gabor elements. We show that physically removing local elements from the array attenuated global speed discrimination. However, removing awareness of the local elements only had a small effect on speed discrimination. That is, unconscious local motion elements contributed to global conscious speed perception. In Experiment 2 we measured the global speed of the moving Gabor patterns, when half the elements moved at different speeds. We show that global speed averaging occurred regardless of whether local elements were removed from awareness, such that the speed of invisible elements continued to be averaged together with the visible elements to determine the global speed. These data suggest that contextual motion signals outside of awareness can both boost and affect our experience of motion speed, and suggest that such pooling of motion signals occurs before the conscious extraction of the surround motion speed. PMID:25503603
Local motion adaptation enhances the representation of spatial structure at EMD arrays
Lindemann, Jens P.; Egelhaaf, Martin
2017-01-01
Neuronal representation and extraction of spatial information are essential for behavioral control. For flying insects, a plausible way to gain spatial information is to exploit distance-dependent optic flow that is generated during translational self-motion. Optic flow is computed by arrays of local motion detectors retinotopically arranged in the second neuropile layer of the insect visual system. These motion detectors have adaptive response characteristics, i.e. their responses to motion with a constant or only slowly changing velocity decrease, while their sensitivity to rapid velocity changes is maintained or even increases. We analyzed by a modeling approach how motion adaptation affects signal representation at the output of arrays of motion detectors during simulated flight in artificial and natural 3D environments. We focused on translational flight, because spatial information is only contained in the optic flow induced by translational locomotion. Indeed, flies, bees and other insects segregate their flight into relatively long intersaccadic translational flight sections interspersed with brief and rapid saccadic turns, presumably to maximize periods of translation (80% of the flight). With a novel adaptive model of the insect visual motion pathway we could show that the motion detector responses to background structures of cluttered environments are largely attenuated as a consequence of motion adaptation, while responses to foreground objects stay constant or even increase. This conclusion even holds under the dynamic flight conditions of insects. PMID:29281631
NASA Astrophysics Data System (ADS)
Saharan, Lokesh; Sharma, Ashvath; Jung de Andrade, Monica; Baughman, Ray H.; Tadesse, Yonas
2017-04-01
Partial or total upper extremity impairment affects the quality of life of a vast number of people due to stroke, neuromuscular disease, or trauma. Many researchers have presented hand orthosis to address the needs of rehabilitation or assistance on upper extremity function. Most of the devices available commercially and in literature are powered by conventional actuators such as DC motors, servomotors or pneumatic actuators. Some prototypes are developed based on shape memory alloy (SMA) and dielectric elastomers (DE). This study presents a customizable, 3D printed, a lightweight exoskeleton (iGrab) based on recently reported Twisted and Coiled Polymer (TCP) muscles, which are lightweight, provide high power to weight ratio and large stroke. We used silver coated nylon 6, 6 threads to make the TCP muscles, which can be easily actuated electrothermally. We reviewed briefly hand orthosis created with various actuation technologies and present our design of tendon-driven exoskeleton with the muscles confined in the forearm area. A single muscle is used to facilitate the motion of all three joints namely DIP (Distal interphalangeal), PIP (Proximal Interphalangeal) and MCP (Metacarpophalangeal) using passive tendons though circular rings. The grasping capabilities, along with TCP muscle properties utilized in the design such as life cycle, actuation under load and power inputs are discussed.
Field station as stage: Re-enacting scientific work and life in Amani, Tanzania.
Geissler, P Wenzel; Kelly, Ann H
2016-12-01
Located high in Tanzania's Usambara Mountains, Amani Hill Station has been a site of progressive scientific endeavours for over a century, pushing the boundaries of botanical, zoological and medical knowledge, and providing expertise for imperial expansion, colonial welfare, national progress and international development efforts. The station's heyday was from the 1950s to the 1970s, a period of global disease eradication campaigns and the 'Africanization' of science. Today, Amani lies in a state of suspended motion. Officially part of a national network of medical research stations, its buildings and vegetation are only minimally maintained, and although some staff report for duty, scientific work has ceased. Neither ruin nor time capsule, Amani has become a quiet site of remains and material traces. This article examines the methodological potentials of re-enactment - on-site performances of past research practices - to engage ethnographically with the distinct temporalities and affective registers of life at the station. The heuristic power of re-enactment resides in its anachronicity, the tensions it introduces between immediacy and theatricality, authenticity and artifice, fidelity and futility. We suggest that re-enacting early post-colonial science as events unfolding in the present disrupts straightforward narratives about the promises and shortfalls of scientific progress, raising provocative questions about the sentiments and stakes of research in 'the tropics'.
Senses, Erkan; Tyagi, Madhusudan; Natarajan, Bharath; Narayanan, Suresh; Faraone, Antonio
2017-11-08
The effect of large deformation on the chain dynamics in attractive polymer nanocomposites was investigated using neutron scattering techniques. Quasi-elastic neutron backscattering measurements reveal a substantial reduction of polymer mobility in the presence of attractive, well-dispersed nanoparticles. In addition, large deformations are observed to cause a further slowing down of the Rouse rates at high particle loadings, where the interparticle spacings are slightly smaller than the chain dimensions, i.e. in the strongly confined state. No noticeable change, however, was observed for a lightly confined system. The reptation tube diameter, measured by neutron spin echo, remained unchanged after shear, suggesting that the level of chain-chain entanglements is not significantly affected. The shear-induced changes in the interparticle bridging reflect the slow nanoparticle motion measured by X-ray photon correlation spectroscopy. These results provide a first step for understanding how large shear can significantly affect the segmental motion in nanocomposites and open up new opportunities for designing mechanically responsive soft materials.
Senses, Erkan; Tyagi, Madhusudan; Natarajan, Bharath; ...
2017-09-28
The effect of large deformation on the chain dynamics in attractive polymer nanocomposites was investigated using neutron scattering techniques. Quasielastic neutron backscattering measurements reveal a substantial reduction of polymer mobility in the presence of attractive, well-dispersed nanoparticles. Additionally, large deformations are observed to cause a further slowing down of the Rouse rates at high particle loadings, where the interparticle spacings are slightly smaller than the chain dimensions, i.e. in the strongly confined state. No noticeable change, however, was observed for a lightly confined system. The reptation tube diameter, measured by neutron spin echo, remained unchanged after shear, suggesting that themore » level of chain-chain entanglements is not significantly affected. The shearinduced changes in the interparticle bridging reflects on the slow nanoparticle motion measured by X-ray photon correlation spectroscopy. These results provide a first step for understanding how large shear can significantly affect the segmental motion in nanocomposites and open up new opportunities for designing mechanically responsive soft materials.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Senses, Erkan; Tyagi, Madhusudan; Natarajan, Bharath
The effect of large deformation on the chain dynamics in attractive polymer nanocomposites was investigated using neutron scattering techniques. Quasielastic neutron backscattering measurements reveal a substantial reduction of polymer mobility in the presence of attractive, well-dispersed nanoparticles. Additionally, large deformations are observed to cause a further slowing down of the Rouse rates at high particle loadings, where the interparticle spacings are slightly smaller than the chain dimensions, i.e. in the strongly confined state. No noticeable change, however, was observed for a lightly confined system. The reptation tube diameter, measured by neutron spin echo, remained unchanged after shear, suggesting that themore » level of chain-chain entanglements is not significantly affected. The shearinduced changes in the interparticle bridging reflects on the slow nanoparticle motion measured by X-ray photon correlation spectroscopy. These results provide a first step for understanding how large shear can significantly affect the segmental motion in nanocomposites and open up new opportunities for designing mechanically responsive soft materials.« less
Johnson, Kerri L; McKay, Lawrie S; Pollick, Frank E
2011-05-01
Gender stereotypes have been implicated in sex-typed perceptions of facial emotion. Such interpretations were recently called into question because facial cues of emotion are confounded with sexually dimorphic facial cues. Here we examine the role of visual cues and gender stereotypes in perceptions of biological motion displays, thus overcoming the morphological confounding inherent in facial displays. In four studies, participants' judgments revealed gender stereotyping. Observers accurately perceived emotion from biological motion displays (Study 1), and this affected sex categorizations. Angry displays were overwhelmingly judged to be men; sad displays were judged to be women (Studies 2-4). Moreover, this pattern remained strong when stimuli were equated for velocity (Study 3). We argue that these results were obtained because perceivers applied gender stereotypes of emotion to infer sex category (Study 4). Implications for both vision sciences and social psychology are discussed. Copyright © 2011 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Veerendra K.; Mamontov, Eugene; Anunciado, Divina B.
Antimicrobial peptides are universal in all forms of life and are well known for their strong interaction with the cell membrane. This makes them a popular target for investigation of peptide-lipid interactions. Here we report the effect of melittin, an important antimicrobial peptide, on the dynamics of membranes based on 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) lipid in both the solid gel and fluid phases. To probe the phase transition, elastic neutron intensity temperature scans have been carried out on DMPC-based unilamellar vesicles (ULV) with and without melittin. We have found that addition of a small amount (0.2 mol%) melittin eliminates the steep fallmore » in the elastic intensity at 296 K associated with the solid gel to fluid phase transition, which is observed for pure DMPC vesicles. Quasielastic neutron scattering (QENS) experiments have been carried out on DMPC ULV in the solid gel and fluid phases with and without 0.2 mol % melittin. The data analysis invariably shows the presence of lateral and internal motions of the DMPC molecule. We found that melittin does have a profound effect on the dynamics of lipid molecules, especially on the lateral motion, and affects it in a different way, depending on the phase of the bilayers. In the solid gel phase, it acts as a plasticizer, enhancing the lateral motion of DMPC. However, in the fluid phase it acts as a stiffening agent, restricting the lateral motion of the lipid molecules. These observations are consistent with the mean squared displacements extracted from the elastic intensity temperature scans. Cholesterol is a vital component of eukaryotic membrane, which is a natural target for melittin. To investigate the effect of melittin on vesicles supplemented with cholesterol, QENS experiments have also been carried out on DMPC ULV with 20 mol% cholesterol in the presence and absence of 0.2 mol% melittin. Remarkably, the effects of melittin on the membrane dynamics disappear in the presence of 20 mol % cholesterol. Thus, our measurements indicate that the destabilizing effect of the peptide melittin on membranes can be mitigated by the presence of cholesterol.« less
Sharma, Veerendra K.; Mamontov, Eugene; Anunciado, Divina B.; ...
2015-06-24
Antimicrobial peptides are universal in all forms of life and are well known for their strong interaction with the cell membrane. This makes them a popular target for investigation of peptide-lipid interactions. Here we report the effect of melittin, an important antimicrobial peptide, on the dynamics of membranes based on 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) lipid in both the solid gel and fluid phases. To probe the phase transition, elastic neutron intensity temperature scans have been carried out on DMPC-based unilamellar vesicles (ULV) with and without melittin. We have found that addition of a small amount (0.2 mol%) melittin eliminates the steep fallmore » in the elastic intensity at 296 K associated with the solid gel to fluid phase transition, which is observed for pure DMPC vesicles. Quasielastic neutron scattering (QENS) experiments have been carried out on DMPC ULV in the solid gel and fluid phases with and without 0.2 mol % melittin. The data analysis invariably shows the presence of lateral and internal motions of the DMPC molecule. We found that melittin does have a profound effect on the dynamics of lipid molecules, especially on the lateral motion, and affects it in a different way, depending on the phase of the bilayers. In the solid gel phase, it acts as a plasticizer, enhancing the lateral motion of DMPC. However, in the fluid phase it acts as a stiffening agent, restricting the lateral motion of the lipid molecules. These observations are consistent with the mean squared displacements extracted from the elastic intensity temperature scans. Cholesterol is a vital component of eukaryotic membrane, which is a natural target for melittin. To investigate the effect of melittin on vesicles supplemented with cholesterol, QENS experiments have also been carried out on DMPC ULV with 20 mol% cholesterol in the presence and absence of 0.2 mol% melittin. Remarkably, the effects of melittin on the membrane dynamics disappear in the presence of 20 mol % cholesterol. Thus, our measurements indicate that the destabilizing effect of the peptide melittin on membranes can be mitigated by the presence of cholesterol.« less
Ceca, Diego; Elvira, Laura; Guzmán, José F; Pablos, Ana
2017-01-01
Fibromyalgia (FM) is a disease with symptoms that significantly limit the life of affected patients. Earlier studies have shown that the application of self-myofascial release provides benefits in variables such as fatigue, range of motion (ROM) or perceived muscle pain in a healthy population. Despite this, the self-myofascial release technique has not yet been used in people with FM. This study aimed to find out the benefits of applying a self-myofascial release program on health-related quality of life in people with FM. Sixty-six participants with FM were randomized into two groups, intervention (N.=33) and control (N.=33). The intervention group (IG) participated in the self-myofascial release program for twenty weeks. The study assessed the impact of a self-myofascial release program on cervical spine, shoulder and hip ROM and self-reported disease impact. Two measurements were performed, one at baseline (preintervention) and one postintervention. Two-way mixed-effect (between-within) ANOVA was used for the statistical analysis. Significant changes (P<0.05) were achieved between the two measurements and between groups for final Fibromyalgia Impact Questionnaire (FIQ-S) Score and for five of its seven subscales, including: days per week feeling good, pain intensity, fatigue, stiffness and depression/sadness, as well as all the ROM variables evaluated (neck flexion, neck extension, lateral neck flexion and rotation (bilateral), shoulder flexion and abduction and hip abduction) excluding hip flexion. The application of a self-myofascial release program can improve the health-related quality of life of people with FM, provided that regular, structured practice is carried out.
Conzo, Giovanni; Allaria, Alfredo; Stanzione, Francesco; Rossetti, Gianluca; Candela, Giancarlo; Mauriello, Claudio; Fei, Landino; Santini, Luigi
2012-01-01
The Authors present their experience with laparoscopic total or subtotal colectomy (TC or SC) in three patients operated for intractable chronic slow transit constipation (STC), together with a review of literature. From July 2005 to July 2009 three young patients affected by STC, after meticulous preoperative instrumental work-up and after failure of medical treatment, were submitted to laparoscopic TC and ideo rectal anastomosis (IRA) in two cases and to laparo assisted SC followed by Ceco Rectal Anastomosis (CRA) in one case. Number of daily bowel motions, urgency soiling, incontinence, abdominal pain, bloating with special regard to patient's quality of life, were analyzed. All the interventions were completed via laparoscopic approach. No postoperative morbidity or mortality were observed. After twelve months, the patients referred two-three daily evacuation of soft stool, with a good continence and disappearance of abdominal pain and other relatives symptoms. They reported excellent satisfaction with the surgical results and a significant improvement of their quality of life. TC with IRA and CRA after SC represent the most effective and widely used surgical operations in the treatment of STC, in well selected patients, after failure of conservative treatment. According to Literature data, and in our experience, no significant differences in terms of postoperative morbidity or mortality neither in quality of life were observed between the two operations. It is well demonstrated the feasibility of the laparoscopic approach in treatment of colorectal pathologies with typically advantages of less invasive surgery, respect of parietal integrity, less postoperative pain and ileus, fewer postoperative adhesions, a reduced hospitalisation and finally a better cosmesis. Laparoscopic TC and IRA and CRA after laparo assisted SC represent efficacious operations in the treatment of STC offering a good postoperative quality of life and reduced morbidity compared to open surgery.
Cullen, Kathleen E.
2014-01-01
The vestibular system is vital for maintaining an accurate representation of self-motion. As one moves (or is moved) toward a new place in the environment, signals from the vestibular sensors are relayed to higher-order centers. It is generally assumed the vestibular system provides a veridical representation of head motion to these centers for the perception of self-motion and spatial memory. In support of this idea, evidence from lesion studies suggests that vestibular inputs are required for the directional tuning of head direction cells in the limbic system as well as neurons in areas of multimodal association cortex. However, recent investigations in monkeys and mice challenge the notion that early vestibular pathways encode an absolute representation of head motion. Instead, processing at the first central stage is inherently multimodal. This minireview highlights recent progress that has been made towards understanding how the brain processes and interprets self-motion signals encoded by the vestibular otoliths and semicircular canals during everyday life. The following interrelated questions are considered. What information is available to the higher-order centers that contribute to self-motion perception? How do we distinguish between our own self-generated movements and those of the external world? And lastly, what are the implications of differences in the processing of these active vs. passive movements for spatial memory? PMID:24454282
Johansson, Adam; Balter, James; Cao, Yue
2018-03-01
Respiratory motion can affect pharmacokinetic perfusion parameters quantified from liver dynamic contrast-enhanced MRI. Image registration can be used to align dynamic images after reconstruction. However, intra-image motion blur remains after alignment and can alter the shape of contrast-agent uptake curves. We introduce a method to correct for inter- and intra-image motion during image reconstruction. Sixteen liver dynamic contrast-enhanced MRI examinations of nine subjects were performed using a golden-angle stack-of-stars sequence. For each examination, an image time series with high temporal resolution but severe streak artifacts was reconstructed. Images were aligned using region-limited rigid image registration within a region of interest covering the liver. The transformations resulting from alignment were used to correct raw data for motion by modulating and rotating acquired lines in k-space. The corrected data were then reconstructed using view sharing. Portal-venous input functions extracted from motion-corrected images had significantly greater peak signal enhancements (mean increase: 16%, t-test, P < 0.001) than those from images aligned using image registration after reconstruction. In addition, portal-venous perfusion maps estimated from motion-corrected images showed fewer artifacts close to the edge of the liver. Motion-corrected image reconstruction restores uptake curves distorted by motion. Motion correction also reduces motion artifacts in estimated perfusion parameter maps. Magn Reson Med 79:1345-1353, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Mercury: The World Closest to the Sun.
ERIC Educational Resources Information Center
Cordell, Bruce M.
1984-01-01
Discusses various topics related to the geology of Mercury including the origin of Mercury's magnetism, Mercury's motions, volcanism, scarps, and Mercury's violent birth and early life. Includes a table comparing Mercury's orbital and physical data to that of earth's. (JN)
People can understand descriptions of motion without activating visual motion brain regions
Dravida, Swethasri; Saxe, Rebecca; Bedny, Marina
2013-01-01
What is the relationship between our perceptual and linguistic neural representations of the same event? We approached this question by asking whether visual perception of motion and understanding linguistic depictions of motion rely on the same neural architecture. The same group of participants took part in two language tasks and one visual task. In task 1, participants made semantic similarity judgments with high motion (e.g., “to bounce”) and low motion (e.g., “to look”) words. In task 2, participants made plausibility judgments for passages describing movement (“A centaur hurled a spear … ”) or cognitive events (“A gentleman loved cheese …”). Task 3 was a visual motion localizer in which participants viewed animations of point-light walkers, randomly moving dots, and stationary dots changing in luminance. Based on the visual motion localizer we identified classic visual motion areas of the temporal (MT/MST and STS) and parietal cortex (inferior and superior parietal lobules). We find that these visual cortical areas are largely distinct from neural responses to linguistic depictions of motion. Motion words did not activate any part of the visual motion system. Motion passages produced a small response in the right superior parietal lobule, but none of the temporal motion regions. These results suggest that (1) as compared to words, rich language stimuli such as passages are more likely to evoke mental imagery and more likely to affect perceptual circuits and (2) effects of language on the visual system are more likely in secondary perceptual areas as compared to early sensory areas. We conclude that language and visual perception constitute distinct but interacting systems. PMID:24009592
Impaired Perception of Biological Motion in Parkinson’s Disease
Jaywant, Abhishek; Shiffrar, Maggie; Roy, Serge; Cronin-Golomb, Alice
2016-01-01
Objective We examined biological motion perception in Parkinson’s disease (PD). Biological motion perception is related to one’s own motor function and depends on the integrity of brain areas affected in PD, including posterior superior temporal sulcus. If deficits in biological motion perception exist, they may be specific to perceiving natural/fast walking patterns that individuals with PD can no longer perform, and may correlate with disease-related motor dysfunction. Method 26 non-demented individuals with PD and 24 control participants viewed videos of point-light walkers and scrambled versions that served as foils, and indicated whether each video depicted a human walking. Point-light walkers varied by gait type (natural, parkinsonian) and speed (0.5, 1.0, 1.5 m/s). Participants also completed control tasks (object motion, coherent motion perception), a contrast sensitivity assessment, and a walking assessment. Results The PD group demonstrated significantly less sensitivity to biological motion than the control group (p<.001, Cohen’s d=1.22), regardless of stimulus gait type or speed, with a less substantial deficit in object motion perception (p=.02, Cohen’s d=.68). There was no group difference in coherent motion perception. Although individuals with PD had slower walking speed and shorter stride length than control participants, gait parameters did not correlate with biological motion perception. Contrast sensitivity and coherent motion perception also did not correlate with biological motion perception. Conclusion PD leads to a deficit in perceiving biological motion, which is independent of gait dysfunction and low-level vision changes, and may therefore arise from difficulty perceptually integrating form and motion cues in posterior superior temporal sulcus. PMID:26949927
Helicopter flight simulation motion platform requirements
NASA Astrophysics Data System (ADS)
Schroeder, Jeffery Allyn
Flight simulators attempt to reproduce in-flight pilot-vehicle behavior on the ground. This reproduction is challenging for helicopter simulators, as the pilot is often inextricably dependent on external cues for pilot-vehicle stabilization. One important simulator cue is platform motion; however, its required fidelity is unknown. To determine the required motion fidelity, several unique experiments were performed. A large displacement motion platform was used that allowed pilots to fly tasks with matched motion and visual cues. Then, the platform motion was modified to give cues varying from full motion to no motion. Several key results were found. First, lateral and vertical translational platform cues had significant effects on fidelity. Their presence improved performance and reduced pilot workload. Second, yaw and roll rotational platform cues were not as important as the translational platform cues. In particular, the yaw rotational motion platform cue did not appear at all useful in improving performance or reducing workload. Third, when the lateral translational platform cue was combined with visual yaw rotational cues, pilots believed the platform was rotating when it was not. Thus, simulator systems can be made more efficient by proper combination of platform and visual cues. Fourth, motion fidelity specifications were revised that now provide simulator users with a better prediction of motion fidelity based upon the frequency responses of their motion control laws. Fifth, vertical platform motion affected pilot estimates of steady-state altitude during altitude repositionings. This refutes the view that pilots estimate altitude and altitude rate in simulation solely from visual cues. Finally, the combined results led to a general method for configuring helicopter motion systems and for developing simulator tasks that more likely represent actual flight. The overall results can serve as a guide to future simulator designers and to today's operators.
NASA Technical Reports Server (NTRS)
Toscano, William B.; Cowings, Patricia S.
1994-01-01
Space motion sickness (SMS) affects 50 percent of all people during early days of spaceflight. This study describes the results of two Shuttle flight experiments in which autogenic-feedback training (AFT), a physiological conditioning method, was tested as a treatment for this disorder. Of the six who were designated as flight subjects (two women and four men), three were given treatment and three served as controls (i.e., no AFT). Treatment subjects were given 6 hours of preflight AFT. Preflight results showed that AFT produced a significant increase in tolerance to rotating chair motion sickness tests. Further, this increased tolerance was associated with changes in specific physiological responses and reports of reduced malaise. Flight results showed that two of the three control subjects experienced repeated vomiting on the first mission day, while one subject experienced only moderate malaise. Of the three treatment subjects, one experienced mild discomfort, one moderate discomfort, and one severe motion sickness. Only the three control subjects took medication for symptom suppression. Measures of cardiac function reflective of vagal control were shown to be affected especially strongly on the first day of space flight. AFT given for control of heart rate, respiration, and other autonomic activity influenced both the vagal control measures and SMS. These data suggest that AFT may be an effective treatment for space motion sickness; however, this cannot be demonstrated conclusively with the small number of subjects described.
Does the anthropometric model influence whole-body center of mass calculations in gait?
Catena, Robert D; Chen, Szu-Hua; Chou, Li-Shan
2017-07-05
Examining whole-body center of mass (COM) motion is one of method being used to quantify dynamic balance and energy during gait. One common method for estimating the COM position is to apply an anthropometric model to a marker set and calculate the weighted sum from known segmental COM positions. Several anthropometric models are available to perform such a calculation. However, to date there has been no study of how the anthropometric model affects whole-body COM calculations during gait. This information is pertinent to researchers because the choice of anthropometric model may influence gait research findings and currently the trend is to consistently use a single model. In this study we analyzed a single stride of gait data from 103 young adult participants. We compared the whole-body COM motion calculated from 4 different anthropometric models (Plagenhoef et al., 1983; Winter, 1990; de Leva, 1996; Pavol et al., 2002). We found that anterior-posterior motion calculations are relatively unaffected by the anthropometric model. However, medial-lateral and vertical motions are significantly affected by the use of different anthropometric models. Our findings suggest that the researcher carefully choose an anthropometric model to fit their study populations when interested in medial-lateral or vertical motions of the COM. Our data can provide researchers a priori information on the model determination depending on the particular variable and how conservative they may want to be with COM comparisons between groups. Copyright © 2017 Elsevier Ltd. All rights reserved.
Bottom boundary layer spectral dissipation estimates in the presence of wave motions
NASA Astrophysics Data System (ADS)
Gross, T. F.; Williams, A. J.; Terray, E. A.
1994-08-01
Turbulence measurements are an essential element of the Sediment TRansport Events on Shelves and Slopes experiment (STRESS). Sediment transport under waves is initiated within the wave boundary layer at the seabed, at most a few tens of centimeters deep. The suspended load is carried by turbulent diffusion above the wave boundary layer. Quantification of the turbulent diffusion active above the wave boundary layer requires estimates of shear stress or energy dissipation in the presence of oscillating flows. Measurements by Benthic Acoustic Stress Sensors of velocity fluctuations were used to derive the dissipation rate from the energy level of the spectral inertial range (the -5/3 spectrum). When the wave orbital velocity is of similar magnitude to the mean flow, kinematic effects on the estimation techniques of stress and dissipation must be included. Throughout the STRESS experiment there was always significant wave energy affecting the turbulent bottom boundary layer. LUMLEY and TERRAY [(1983) Journal of Physical Oceanography, 13, 2000-2007] presented a theory describing the effect of orbital motions on kinetic energy spectra. Their model is used here with observations of spectra taken within a turbulent boundary layer which is affected by wave motion. While their method was an explicit solution for circular wave orbits aligned with mean current we extrapolated it to the case of near bed horizontal motions, not aligned with the current. The necessity of accounting for wave orbital motion is demonstrated, but variability within the field setting limited our certainty of the improvement in accuracy the corrections afforded.
Experience affects the use of ego-motion signals during 3D shape perception
Jain, Anshul; Backus, Benjamin T.
2011-01-01
Experience has long-term effects on perceptual appearance (Q. Haijiang, J. A. Saunders, R. W. Stone, & B. T. Backus, 2006). We asked whether experience affects the appearance of structure-from-motion stimuli when the optic flow is caused by observer ego-motion. Optic flow is an ambiguous depth cue: a rotating object and its oppositely rotating, depth-inverted dual generate similar flow. However, the visual system exploits ego-motion signals to prefer the percept of an object that is stationary over one that rotates (M. Wexler, F. Panerai, I. Lamouret, & J. Droulez, 2001). We replicated this finding and asked whether this preference for stationarity, the “stationarity prior,” is modulated by experience. During training, two groups of observers were exposed to objects with identical flow, but that were either stationary or moving as determined by other cues. The training caused identical test stimuli to be seen preferentially as stationary or moving by the two groups, respectively. We then asked whether different priors can exist independently at different locations in the visual field. Observers were trained to see objects either as stationary or as moving at two different locations. Observers’ stationarity bias at the two respective locations was modulated in the directions consistent with training. Thus, the utilization of extraretinal ego-motion signals for disambiguating optic flow signals can be updated as the result of experience, consistent with the updating of a Bayesian prior for stationarity. PMID:21191132
Mawase, Firas; Karniel, Amir; Donchin, Opher; Rothwell, John; Nisky, Ilana; Davare, Marco
2016-01-01
How motion and sensory inputs are combined to assess an object's stiffness is still unknown. Here, we provide evidence for the existence of a stiffness estimator in the human posterior parietal cortex (PPC). We showed previously that delaying force feedback with respect to motion when interacting with an object caused participants to underestimate its stiffness. We found that applying theta-burst transcranial magnetic stimulation (TMS) over the PPC, but not the dorsal premotor cortex, enhances this effect without affecting movement control. We explain this enhancement as an additional lag in force signals. This is the first causal evidence that the PPC is not only involved in motion control, but also has an important role in perception that is disassociated from action. We provide a computational model suggesting that the PPC integrates position and force signals for perception of stiffness and that TMS alters the synchronization between the two signals causing lasting consequences on perceptual behavior. SIGNIFICANCE STATEMENT When selecting an object such as a ripe fruit or sofa, we need to assess the object's stiffness. Because we lack dedicated stiffness sensors, we rely on an as yet unknown mechanism that generates stiffness percepts by combining position and force signals. Here, we found that the posterior parietal cortex (PPC) contributes to combining position and force signals for stiffness estimation. This finding challenges the classical view about the role of the PPC in regulating position signals only for motion control because we highlight a key role of the PPC in perception that is disassociated from action. Altogether this sheds light on brain mechanisms underlying the interaction between action and perception and may help in the development of better teleoperation systems and rehabilitation of patients with sensory impairments. PMID:27733607
Electrokinetic motion of a rectangular nanoparticle in a nanochannel
NASA Astrophysics Data System (ADS)
Movahed, Saeid; Li, Dongqing
2012-08-01
This article presents a theoretical study of electrokinetic motion of a negatively charged cubic nanoparticle in a three-dimensional nanochannel with a circular cross-section. Effects of the electrophoretic and the hydrodynamic forces on the nanoparticle motion are examined. Because of the large applied electric field over the nanochannel, the impact of the Brownian force is negligible in comparison with the electrophoretic and the hydrodynamic forces. The conventional theories of electrokinetics such as the Poisson-Boltzmann equation and the Helmholtz-Smoluchowski slip velocity approach are no longer applicable in the small nanochannels. In this study, and at each time step, first, a set of highly coupled partial differential equations including the Poisson-Nernst-Plank equation, the Navier-Stokes equations, and the continuity equation was solved to find the electric potential, ionic concentration field, and the flow field around the nanoparticle. Then, the electrophoretic and hydrodynamic forces acting on the negatively charged nanoparticle were determined. Following that, the Newton second law was utilized to find the velocity of the nanoparticle. Using this model, effects of surface electric charge of the nanochannel, bulk ionic concentration, the size of the nanoparticle, and the radius of the nanochannel on the nanoparticle motion were investigated. Increasing the bulk ionic concentration or the surface charge of the nanochannel will increase the electroosmotic flow, and hence affect the particle's motion. It was also shown that, unlike microchannels with thin EDL, the change in nanochannel size will change the EDL field and the ionic concentration field in the nanochannel, affecting the particle's motion. If the nanochannel size is fixed, a larger particle will move faster than a smaller particle under the same conditions.
Oh, Hyun Seung; Kim, Eun Joo; Kim, Doo Young; Kim, Soo Jeong
2016-06-01
To investigate the effects of adjuvant mental practice (MP) on affected upper limb function following a stroke using three-dimensional (3D) motion analysis. In this AB/BA crossover study, we studied 10 hemiplegic patients who had a stroke within the past 6 months. The patients were randomly allocated to two groups: one group received MP combined with conventional rehabilitation therapy for the first 3 weeks followed by conventional rehabilitation therapy alone for the final 3 weeks; the other group received the same therapy but in reverse order. The MP tasks included drinking from a cup and opening a door. MP was individually administered for 20 minutes, 3 days a week for 3 weeks. To assess the tasks, we used 3D motion analysis and three additional tests: the Fugl-Meyer Assessment of the upper extremity (FMA-UE) and the motor activity logs for amount of use (MAL-AOU) and quality of movement (MAL-QOM). Assessments were performed immediately before treatment (T0), 3 weeks into treatment (T1), and 6 weeks into treatment (T2). Based on the results of the 3D motion analysis and the FMA-UE index (p=0.106), the MAL-AOU scale (p=0.092), and MAL-QOM scale (p=0.273), adjuvant MP did not result in significant improvements. Adjuvant MP had no significant effect on upper limb function following a stroke, according to 3D motion analysis and three clinical assessment tools (the FMA-UE index and the two MAL scales). The importance of this study is its use of objective 3D motion analysis to evaluate the effects of MP. Further studies will be needed to validate these findings.
Fukushima, Kikuro; Barnes, Graham R; Ito, Norie; Olley, Peter M; Warabi, Tateo
2014-07-01
Aging affects virtually all functions including sensory/motor and cognitive activities. While retinal image motion is the primary input for smooth-pursuit, its efficiency/accuracy depends on cognitive processes. Elderly subjects exhibit gain decrease during initial and steady-state pursuit, but reports on latencies are conflicting. Using a cue-dependent memory-based smooth-pursuit task, we identified important extra-retinal mechanisms for initial pursuit in young adults including cue information priming and extra-retinal drive components (Ito et al. in Exp Brain Res 229:23-35, 2013). We examined aging effects on parameters for smooth-pursuit using the same tasks. Elderly subjects were tested during three task conditions as previously described: memory-based pursuit, simple ramp-pursuit just to follow motion of a single spot, and popping-out of the correct spot during memory-based pursuit to enhance retinal image motion. Simple ramp-pursuit was used as a task that did not require visual motion working memory. To clarify aging effects, we then compared the results with the previous young subject data. During memory-based pursuit, elderly subjects exhibited normal working memory of cue information. Most movement-parameters including pursuit latencies differed significantly between memory-based pursuit and simple ramp-pursuit and also between young and elderly subjects. Popping-out of the correct spot motion was ineffective for enhancing initial pursuit in elderly subjects. However, the latency difference between memory-based pursuit and simple ramp-pursuit in individual subjects, which includes decision-making delay in the memory task, was similar between the two groups. Our results suggest that smooth-pursuit latencies depend on task conditions and that, although the extra-retinal mechanisms were functional for initial pursuit in elderly subjects, they were less effective.
Psarakis, Michael; Greene, David; Moresi, Mark; Baker, Michael; Stubbs, Peter; Brodie, Matthew; Lord, Stephen; Hoang, Phu
2017-11-01
Gait impairment in people with Multiple Sclerosis results from neurological impairment, muscle weakness and reduced range of motion. Restrictions in passive ankle range of motion can result in abnormal heel-to-toe progression (weight transfer) and inefficient gait patterns in people with Multiple Sclerosis. The purpose of this study was to determine the associations between gait impairment, heel-to-toe progression and ankle range of motion in people with Multiple Sclerosis. Twelve participants with Multiple Sclerosis and twelve healthy age-matched participants were assessed. Spatiotemporal parameters of gait and individual footprint data were used to investigate group differences. A pressure sensitive walkway was used to divide each footprint into three phases (contact, mid-stance, propulsive) and calculate the heel-to-toe progression during the stance phase of gait. Compared to healthy controls, people with Multiple Sclerosis spent relatively less time in contact phase (7.8% vs 25.1%) and more time in the mid stance phase of gait (57.3% vs 33.7%). Inter-limb differences were observed in people with Multiple Sclerosis between the affected and non-affected sides for contact (7.8% vs 15.3%) and mid stance (57.3% and 47.1%) phases. Differences in heel-to-toe progression remained significant after adjusting for walking speed and were correlated with walking distance and ankle range of motion. Impaired heel-to-toe progression was related to poor ankle range of motion in people with Multiple Sclerosis. Heel-to-toe progression provided a sensitive measure for assessing gait impairments that were not detectable using standard spatiotemporal gait parameters. Copyright © 2017 Elsevier Ltd. All rights reserved.
Leib, Raz; Mawase, Firas; Karniel, Amir; Donchin, Opher; Rothwell, John; Nisky, Ilana; Davare, Marco
2016-10-12
How motion and sensory inputs are combined to assess an object's stiffness is still unknown. Here, we provide evidence for the existence of a stiffness estimator in the human posterior parietal cortex (PPC). We showed previously that delaying force feedback with respect to motion when interacting with an object caused participants to underestimate its stiffness. We found that applying theta-burst transcranial magnetic stimulation (TMS) over the PPC, but not the dorsal premotor cortex, enhances this effect without affecting movement control. We explain this enhancement as an additional lag in force signals. This is the first causal evidence that the PPC is not only involved in motion control, but also has an important role in perception that is disassociated from action. We provide a computational model suggesting that the PPC integrates position and force signals for perception of stiffness and that TMS alters the synchronization between the two signals causing lasting consequences on perceptual behavior. When selecting an object such as a ripe fruit or sofa, we need to assess the object's stiffness. Because we lack dedicated stiffness sensors, we rely on an as yet unknown mechanism that generates stiffness percepts by combining position and force signals. Here, we found that the posterior parietal cortex (PPC) contributes to combining position and force signals for stiffness estimation. This finding challenges the classical view about the role of the PPC in regulating position signals only for motion control because we highlight a key role of the PPC in perception that is disassociated from action. Altogether this sheds light on brain mechanisms underlying the interaction between action and perception and may help in the development of better teleoperation systems and rehabilitation of patients with sensory impairments. Copyright © 2016 Leib et al.
Ways that Social Change Predicts Personal Quality of Life
ERIC Educational Resources Information Center
Cheung, Chau-Kiu; Leung, Kwok
2010-01-01
A notable way that social change affects personal quality of life would rely on the person's experience with social change. This experience may influence societal quality of life and quality of work life, which may in turn affect personal quality of life. Additionally, the experience of social change is possibly less detrimental to personal…
Social forces for team coordination in ball possession game
NASA Astrophysics Data System (ADS)
Yokoyama, Keiko; Shima, Hiroyuki; Fujii, Keisuke; Tabuchi, Noriyuki; Yamamoto, Yuji
2018-02-01
Team coordination is a basic human behavioral trait observed in many real-life communities. To promote teamwork, it is important to cultivate social skills that elicit team coordination. In the present work, we consider which social skills are indispensable for individuals performing a ball possession game in soccer. We develop a simple social force model that describes the synchronized motion of offensive players. Comparing the simulation results with experimental observations, we uncovered that the cooperative social force, a measure of perception skill, has the most important role in reproducing the harmonized collective motion of experienced players in the task. We further developed an experimental tool that facilitates real players' perceptions of interpersonal distance, revealing that the tool improves novice players' motions as if the cooperative social force were imposed.
Lubiatowski, Przemyslaw; Kaczmarek, Piotr; Cisowski, Pawel; Breborowicz, Ewa; Grygorowicz, Monika; Dzianach, Marcin; Krupecki, Tomasz; Laver, Lior; Romanowski, Leszek
2018-01-01
Glenohumeral range of motion adaptations may affect throwing athletes and contribute to shoulder injury. The purpose of this study was to evaluate shoulder rotation deficits among elite professional handball players and its correlation to the presence of shoulder pain and morphological changes. Eighty-seven elite professional handball players and 41 healthy non-athlete volunteers participated in the study. Evaluations included measurement of range of internal and external rotation, total arch of motion, identification of shoulder pain and ultrasound scan for diagnosis of rotator cuff tears and internal impingement. Glenohumeral rotational deficits (>20-25°) were found among 11 players group (13%). The throwing shoulders in the players group showed a decrease in internal rotation and an increase in external rotation with significantly larger ranges among players compared to the non-athlete group. Internal rotation deficit >20° was associated with higher incidence of shoulder pain among players. Both internal rotation deficits (>25°) and total arch of motion deficit (>20°) co-existed with higher incidence of internal impingement. Shoulder pain was common (36/97-41%) and was associated with decreased external rotation and total arch of motion. Internal impingement (found in 13/87-15%) correlated with decreased rotation ranges and a greater deficit in total arch of motion, whereas higher gain in external rotation correlated with a partial rotator cuff tear (found in 12/87-14%). Shoulder pathologies and problems commonly affected the group of handball players. Greater glenohumeral rotational deficits in throwing shoulders of handball players correlate with shoulder pain and internal impingement, while increased external rotation with partial rotator cuff tears. Such deficits affect 13% of the athlete population. Major clinical relevance of the study is to monitor handball players' shoulders both clinically and by proper imaging. Evaluation of range of rotation seems to identify shoulders at risk of the pathology. Cross-Sectional study with control group, Level II.
Cheng, Wei; Cornwall, Roger; Crouch, Dustin L; Li, Zhongyu; Saul, Katherine R
2015-06-01
Two potential mechanisms leading to postural and osseous shoulder deformity after brachial plexus birth palsy are muscle imbalance between functioning internal rotators and paralyzed external rotators and impaired longitudinal growth of paralyzed muscles. Our goal was to evaluate the combined and isolated effects of these 2 mechanisms on transverse plane shoulder forces using a computational model of C5-6 brachial plexus injury. We modeled a C5-6 injury using a computational musculoskeletal upper limb model. Muscles expected to be denervated by C5-6 injury were classified as affected, with the remaining shoulder muscles classified as unaffected. To model muscle imbalance, affected muscles were given no resting tone whereas unaffected muscles were given resting tone at 30% of maximal activation. To model impaired growth, affected muscles were reduced in length by 30% compared with normal whereas unaffected muscles remained normal in length. Four scenarios were simulated: normal, muscle imbalance only, impaired growth only, and both muscle imbalance and impaired growth. Passive shoulder rotation range of motion and glenohumeral joint reaction forces were evaluated to assess postural and osseous deformity. All impaired scenarios exhibited restricted range of motion and increased and posteriorly directed compressive glenohumeral joint forces. Individually, impaired muscle growth caused worse restriction in range of motion and higher and more posteriorly directed glenohumeral forces than did muscle imbalance. Combined muscle imbalance and impaired growth caused the most restricted joint range of motion and the highest joint reaction force of all scenarios. Both muscle imbalance and impaired longitudinal growth contributed to range of motion and force changes consistent with clinically observed deformity, although the most substantial effects resulted from impaired muscle growth. Simulations suggest that treatment strategies emphasizing treatment of impaired longitudinal growth are warranted for reducing deformity after brachial plexus birth palsy. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Comparison of pitch rate history effects on dynamic stall
NASA Technical Reports Server (NTRS)
Chandrasekhara, M. S.; Carr, Lawrence W.; Ahmed, S.
1992-01-01
Dynamic stall of an airfoil is a classic case of forced unsteady separated flow. Flow separation is brought about by large incidences introduced by the large amplitude unsteady pitching motion of an airfoil. One of the parameters that affects the dynamic stall process is the history of the unsteady motion. In addition, the problem is complicated by the effects of compressibility that rapidly appear over the airfoil even at low Mach numbers at moderately high angles of attack. Consequently, it is of interest to know the effects of pitch rate history on the dynamic stall process. This abstract compares the results of a flow visualization study of the problem with two different pitch rate histories, namely, oscillating airfoil motion and a linear change in the angle of attack due to a transient pitching motion.
Suppression of extraneous thermal noise in cavity optomechanics.
Zhao, Yi; Wilson, Dalziel J; Ni, K-K; Kimble, H J
2012-02-13
Extraneous thermal motion can limit displacement sensitivity and radiation pressure effects, such as optical cooling, in a cavity-optomechanical system. Here we present an active noise suppression scheme and its experimental implementation. The main challenge is to selectively sense and suppress extraneous thermal noise without affecting motion of the oscillator. Our solution is to monitor two modes of the optical cavity, each with different sensitivity to the oscillator's motion but similar sensitivity to the extraneous thermal motion. This information is used to imprint "anti-noise" onto the frequency of the incident laser field. In our system, based on a nano-mechanical membrane coupled to a Fabry-Pérot cavity, simulation and experiment demonstrate that extraneous thermal noise can be selectively suppressed and that the associated limit on optical cooling can be reduced.
Simmons, Andrea Megela; Flores, Victoria
2012-04-01
In their shallow-water habitats, bullfrog (Rana catesbeiana) tadpoles are exposed to both underwater and airborne sources of acoustic stimulation. We probed the representation of underwater particle motion throughout the tadpole's dorsal medulla to determine its spatial extent over larval life. Using neurobiotin-filled micropipettes, we recorded neural activity to z-axis particle motion (frequencies of 40-200 Hz) in the medial vestibular nucleus, lateral vestibular nucleus, dorsal medullary nucleus (DMN), and along the dorsal arcuate pathway. Sensitivity was comparable in the medial and lateral vestibular nuclei, with estimated thresholds between 0.016 and 12.5 μm displacement. Neither best responding frequency nor estimated threshold varied significantly over larval stage. Transport of neurobiotin from active recording sites was also stable over development. The DMN responded poorly to z-axis particle motion, but did respond to low-frequency pressure stimulation. These data suggest that particle motion is represented widely and stably in the tadpole's vestibular medulla. This is in marked contrast to the representation of pressure stimulation in the auditory midbrain, where a transient "deaf period" of non-responsiveness and decreased connectivity occurs immediately prior to metamorphic climax. We suggest that, in bullfrogs, sensitivity to particle motion and to pressure follows different developmental trajectories.
Flores, Victoria
2012-01-01
In their shallow-water habitats, bullfrog (Rana catesbeiana) tadpoles are exposed to both underwater and airborne sources of acoustic stimulation. We probed the representation of underwater particle motion throughout the tadpole’s dorsal medulla to determine its spatial extent over larval life. Using neurobiotin-filled micropipettes, we recorded neural activity to z-axis particle motion (frequencies of 40–200 Hz) in the medial vestibular nucleus, lateral vestibular nucleus, dorsal medullary nucleus (DMN), and along the dorsal arcuate pathway. Sensitivity was comparable in the medial and lateral vestibular nuclei, with estimated thresholds between 0.016 and 12.5 μm displacement. Neither best responding frequency nor estimated threshold varied significantly over larval stage. Transport of neurobiotin from active recording sites was also stable over development. The DMN responded poorly to z-axis particle motion, but did respond to low-frequency pressure stimulation. These data suggest that particle motion is represented widely and stably in the tadpole’s vestibular medulla. This is in marked contrast to the representation of pressure stimulation in the auditory midbrain, where a transient “deaf period” of non-responsiveness and decreased connectivity occurs immediately prior to metamorphic climax. We suggest that, in bullfrogs, sensitivity to particle motion and to pressure follows different developmental trajectories. PMID:22198742
Reactive Resonances in N+N2 Exchange Reaction
NASA Technical Reports Server (NTRS)
Wang, Dunyou; Huo, Winifred M.; Dateo, Christopher E.; Schwenke, David W.; Stallcop, James R.
2003-01-01
Rich reactive resonances are found in a 3D quantum dynamics study of the N + N2 exchange reaction using a recently developed ab initio potential energy surface. This surface is characterized by a feature in the interaction region called Lake Eyring , that is, two symmetric transition states with a shallow minimum between them. An L2 analysis of the quasibound states associated with the shallow minimum confirms that the quasibound states associated with oscillations in all three degrees of freedom in Lake Eyring are responsible for the reactive resonances in the state-to-state reaction probabilities. The quasibound states, mostly the bending motions, give rise to strong reasonance peaks, whereas other motions contribute to the bumps and shoulders in the resonance structure. The initial state reaction probability further proves that the bending motions are the dominating factors of the reaction probability and have longer life times than the stretching motions. This is the first observation of reactive resonances from a "Lake Eyring" feature in a potential energy surface.
General features of the retinal connectome determine the computation of motion anticipation
Johnston, Jamie; Lagnado, Leon
2015-01-01
Motion anticipation allows the visual system to compensate for the slow speed of phototransduction so that a moving object can be accurately located. This correction is already present in the signal that ganglion cells send from the retina but the biophysical mechanisms underlying this computation are not known. Here we demonstrate that motion anticipation is computed autonomously within the dendritic tree of each ganglion cell and relies on feedforward inhibition. The passive and non-linear interaction of excitatory and inhibitory synapses enables the somatic voltage to encode the actual position of a moving object instead of its delayed representation. General rather than specific features of the retinal connectome govern this computation: an excess of inhibitory inputs over excitatory, with both being randomly distributed, allows tracking of all directions of motion, while the average distance between inputs determines the object velocities that can be compensated for. DOI: http://dx.doi.org/10.7554/eLife.06250.001 PMID:25786068
a Study on Impact Analysis of Side Kick in Taekwondo
NASA Astrophysics Data System (ADS)
Lee, Jung-Hyun; Lee, Young-Shin; Han, Kyu-Hyun
Taekwondo is a martial art form and sport that uses the hands and feet for attack and defense. Taekwondo basic motion is composed of the breaking, competition and poomsea motions. The side kick is one of the most important breaking motions. The side kick with the front foot can be made in two steps. In the first step, the front foot is extended forward from the back stance free-fighting position. For the second step, the rear foot is followed simultaneously. Then, the side kick is executed while the entire body weight rests on the rear foot. In this paper, the impact analysis on a human model for kicking posture was carried out. The ADAMS/LifeMOD used numerical modeling and simulation for the side kick. The numerical human models for assailant and opponent in competition motion were developed. The maximum impact force on the human body was obtained by experiment and was applied to impact simulation. As a result, the impact displacement and velocity of the numerical human model were investigated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elliott, Stephen J.; Ni, Guangjian
The pressure distribution in each of the fluid chambers of the cochlea can be decomposed into a 1D, or plane wave, component and a near field component, which decays rapidly away from the excitation point. The transverse motion of the basilar membrane, BM, for example, generates both a 1D pressure field, which couples into the slow wave, and a local near field pressure, proportional to the BM acceleration, that generates an added mass on the BM due to the fluid motion. When the organ of Corti, OC, undergoes internal motion, due for example to outer hair cell activity, this motionmore » will not itself generate any 1D pressure if the OC is incompressible and the BM is constrained not to move volumetrically, and so will not directly couple into the slow wave. This motion will, however, generate a near field pressure, proportional to the OC acceleration, which will act on the OC and thus increases its effective mass. The near field pressure due to this OC motion will also act on the BM, generating a force on the BM proportional to the acceleration of the OC, and thus create a “coupling mass” effect. By reciprocity, this coupling mass is the same as that acting on the OC due to the motion of the BM. This near field fluid coupling is initially observed in a finite element model of a slice of the cochlea. These simulations suggest a simple analytical formulation for the fluid coupling, using higher order beam modes across the width of the cochlear partition. It is well known that the added mass due to the near field pressure dominates the overall mass of the BM, and thus significantly affects the micromechanical dynamics. This work not only quantifies the added mass of the OC due its own motion in the fluid, and shows that this is important, but also demonstrates that the coupling mass effect between the BM and OC significantly affects the dynamics of simple micromechanical models.« less
Motion Tracker: Camera-Based Monitoring of Bodily Movements Using Motion Silhouettes
Westlund, Jacqueline Kory; D’Mello, Sidney K.; Olney, Andrew M.
2015-01-01
Researchers in the cognitive and affective sciences investigate how thoughts and feelings are reflected in the bodily response systems including peripheral physiology, facial features, and body movements. One specific question along this line of research is how cognition and affect are manifested in the dynamics of general body movements. Progress in this area can be accelerated by inexpensive, non-intrusive, portable, scalable, and easy to calibrate movement tracking systems. Towards this end, this paper presents and validates Motion Tracker, a simple yet effective software program that uses established computer vision techniques to estimate the amount a person moves from a video of the person engaged in a task (available for download from http://jakory.com/motion-tracker/). The system works with any commercially available camera and with existing videos, thereby affording inexpensive, non-intrusive, and potentially portable and scalable estimation of body movement. Strong between-subject correlations were obtained between Motion Tracker’s estimates of movement and body movements recorded from the seat (r =.720) and back (r = .695 for participants with higher back movement) of a chair affixed with pressure-sensors while completing a 32-minute computerized task (Study 1). Within-subject cross-correlations were also strong for both the seat (r =.606) and back (r = .507). In Study 2, between-subject correlations between Motion Tracker’s movement estimates and movements recorded from an accelerometer worn on the wrist were also strong (rs = .801, .679, and .681) while people performed three brief actions (e.g., waving). Finally, in Study 3 the within-subject cross-correlation was high (r = .855) when Motion Tracker’s estimates were correlated with the movement of a person’s head as tracked with a Kinect while the person was seated at a desk (Study 3). Best-practice recommendations, limitations, and planned extensions of the system are discussed. PMID:26086771
SU-F-J-116: Clinical Experience-Based Verification and Improvement of a 4DCT Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fogg, P; West, M; Aland, T
2016-06-15
Purpose: To demonstrate the role of continuous improvement fulfilled by the Medical Physicist in clinical 4DCT and CBCT scanning. Methods: Lung (SABR and Standard) patients’ 4D respiratory motion and image data were reviewed over a 3, 6 and 12 month period following commissioning testing. By identifying trends of clinically relevant parameters and respiratory motions, variables were tested with a programmable motion phantom and assessed. Patient traces were imported to a motion phantom and 4DCT and CBCT imaging were performed. Cos6 surrogate and sup-inf motion was also programmed into the phantom to simulate the long exhale of patients for image contrastmore » tests. Results: Patient surrogate motion amplitudes were 9.9+5.2mm (3–35) at 18+6bpm (6–30). Expiration/Inspiration time ratios of 1.4+0.5second (0.6–2.9) showed image contrast effects evident in the AveCT and 3DCBCT images. Small differences were found for patients with multiple 4DCT data sets. Patient motion assessments were simulated and verified with the phantom within 2mm. Initial image reviews to check for reconstructed artefacts and data loss identified a small number of patients with irregularities in the automatic placement of inspiration and expiration points. Conclusion: The Physicist’s involvement in the continuous improvements of a clinically commissioned technique, processes and workflows continues beyond the commissioning stage of a project. Our experience with our clinical 4DCT program shows that Physics presence is required at the clinical 4DCT scan to assist with technical aspects of the scan and also for clinical image quality assessment prior to voluming. The results of this work enabled the sharing of information from the Medical Physics group with the Radiation Oncologists and Radiation Therapists. This results in an improved awareness of clinical patient respiration variables and how they may affect 4D simulation images and also may also affect the treatment verification images.« less
Classifying prosthetic use via accelerometry in persons with transtibial amputations.
Redfield, Morgan T; Cagle, John C; Hafner, Brian J; Sanders, Joan E
2013-01-01
Knowledge of how persons with amputation use their prostheses and how this use changes over time may facilitate effective rehabilitation practices and enhance understanding of prosthesis functionality. Perpetual monitoring and classification of prosthesis use may also increase the health and quality of life for prosthetic users. Existing monitoring and classification systems are often limited in that they require the subject to manipulate the sensor (e.g., attach, remove, or reset a sensor), record data over relatively short time periods, and/or classify a limited number of activities and body postures of interest. In this study, a commercially available three-axis accelerometer (ActiLife ActiGraph GT3X+) was used to characterize the activities and body postures of individuals with transtibial amputation. Accelerometers were mounted on prosthetic pylons of 10 persons with transtibial amputation as they performed a preset routine of actions. Accelerometer data was postprocessed using a binary decision tree to identify when the prosthesis was being worn and to classify periods of use as movement (i.e., leg motion such as walking or stair climbing), standing (i.e., standing upright with limited leg motion), or sitting (i.e., seated with limited leg motion). Classifications were compared to visual observation by study researchers. The classifier achieved a mean +/- standard deviation accuracy of 96.6% +/- 3.0%.
Classifying Prosthetic Use via Accelerometry in Persons with Trans-Tibial Amputations
Redfield, Morgan T.; Cagle, John C.; Hafner, Brian J.; Sanders, Joan E.
2014-01-01
Knowledge of how persons with amputation use their prostheses and how this use changes over time may facilitate effective rehabilitation practices and enhance understanding of prosthesis functionality. Perpetual monitoring and classification of prosthesis use may also increase the health and quality of life for prosthetic users. Existing monitoring and classification systems are often limited in that they require the subject to manipulate the sensor (e.g., attach, remove, or reset a sensor), record data over relatively short time periods, and/or classify a limited number of activities and body postures of interest. In this study, a commercially-available three-axis accelerometer (ActiLife ActiGraph GT3X+) was used to characterize the activities and body postures of individuals with trans-tibial amputation. Accelerometers were mounted on prosthetic pylons of ten persons with trans-tibial amputation as they performed a preset routine of actions. Accelerometer data was post-processed using a Binary Decision Tree to identify when the prosthesis was being worn and to classify periods of use as movement (i.e., leg motion like walking or stair climbing), standing (i.e., standing upright with limited leg motion), or sitting (i.e., seated with limited leg motion). Classifications were compared to visual observation by study researchers. The classifier achieved a mean accuracy of 96.6% (SD=3.0%). PMID:24458961
Grouping of optic flow stimuli during binocular rivalry is driven by monocular information.
Holten, Vivian; Stuit, Sjoerd M; Verstraten, Frans A J; van der Smagt, Maarten J
2016-10-01
During binocular rivalry, perception alternates between two dissimilar images, presented dichoptically. Although binocular rivalry is thought to result from competition at a local level, neighboring image parts with similar features tend to be perceived together for longer durations than image parts with dissimilar features. This simultaneous dominance of two image parts is called grouping during rivalry. Previous studies have shown that this grouping depends on a shared eye-of-origin to a much larger extent than on image content, irrespective of the complexity of a static image. In the current study, we examine whether grouping of dynamic optic flow patterns is also primarily driven by monocular (eye-of-origin) information. In addition, we examine whether image parameters, such as optic flow direction, and partial versus full visibility of the optic flow pattern, affect grouping durations during rivalry. The results show that grouping of optic flow is, as is known for static images, primarily affected by its eye-of-origin. Furthermore, global motion can affect grouping durations, but only under specific conditions. Namely, only when the two full optic flow patterns were presented locally. These results suggest that grouping during rivalry is primarily driven by monocular information even for motion stimuli thought to rely on higher-level motion areas. Copyright © 2016 Elsevier Ltd. All rights reserved.
The Development of Humeral Retrotorsion and Its Relationship to Throwing Sports.
Greenberg, Elliot M; Fernandez-Fernandez, Alicia; Lawrence, J Todd R; McClure, Philip
2015-01-01
Several investigations have noted that throwing athletes exhibit a more posteriorly oriented humeral head (humeral retrotorsion) in the dominant arm. This asymmetry is believed to represent an adaptive response to the stress of throwing that occurs during childhood. The significance of this alteration and factors that affect its development are currently not clear. Basic science, research studies, and review articles were searched through PubMed with search terms including humeral torsion, humeral retrotorsion, and with 1 of the following: pediatric, adult, baseball, pitching, shoulder, and range of motion. The references from each article were reviewed for further inclusion. This review included articles through March 2015. Clinical review. Level 4. The throwing motion creates stressors that result in bony adaptations that occur while skeletally immature. These osseous changes likely contribute to the observed shift in the arc of rotational range of motion noted in throwing athletes and may play a protective role against injury. However, too much or too little retrotorsion may predispose the shoulder to injury. The degree of "optimal" humeral retrotorsion and factors that influence its development are not fully understood. Evidence supports the assertion that the throwing motion creates stressors that alter bony anatomy while young. It is important to determine what specific factors affect this adaptation and its relationship to injury. © 2015 The Author(s).
Does insertion of intramuscular electromyographic electrodes alter motor behavior during locomotion?
Armour Smith, Jo; Kulig, Kornelia
2015-06-01
Intramuscular electromyography (EMG) is commonly used to quantify activity in the trunk musculature. However, it is unclear if the discomfort or fear of pain associated with insertion of intramuscular EMG electrodes results in altered motor behavior. This study examined whether intramuscular EMG affects locomotor speed and trunk motion, and examined the anticipated and actual pain associated with electrode insertion in healthy individuals and individuals with a history of low back pain (LBP). Before and after insertion of intramuscular electrodes into the lumbar and thoracic paraspinals, participants performed multiple repetitions of a walking turn at self-selected and controlled average speed. Low levels of anticipated and actual pain were reported in both groups. Self-selected locomotor speed was significantly increased following insertion of the electrodes. At the controlled speed, the amplitude of sagittal plane lumbo-pelvic motion decreased significantly post-insertion, but the extent of this change was the same in both groups. Lumbo-pelvic motion in the frontal and axial planes and thoraco-lumbar motion in all planes were not affected by the insertions. This study demonstrates that intramuscular EMG is an appropriate methodology to selectively quantify the activation patterns of the individual muscles in the paraspinal group, both in healthy individuals and individuals with a history of LBP. Copyright © 2015 Elsevier Ltd. All rights reserved.
A qualitative study of work-life balance amongst specialist orthodontists in the United Kingdom.
Bateman, Lindsey E; Collins, Joanne M; Cunningham, Susan J
2016-12-01
To identify factors affecting work-life balance amongst male and female orthodontists in the UK. A qualitative interview-based study with a cross-sectional design. Specialist orthodontists working in specialist practice and the hospital service in the UK were selected by purposive sampling. In-depth semi-structured interviews were conducted with 18 orthodontic specialists. Interview transcripts were analyzed using Framework Analysis. Four main themes pertaining to work-life balance in orthodontics were identified: work factors affecting work-life balance, life factors affecting work-life balance, perception and effects of work-life balance and suggestions for managing work-life balance within the profession. There was substantial variation in the work-life balance of the orthodontists interviewed in this study; however the majority reported high levels of career satisfaction despite difficulties maintaining a good work-life balance. Whilst there were some clear distinctions in the factors affecting work-life balance between the hospital environment and specialist practice (including additional professional commitments and teaching/training-related issues), there were also a number of similarities. These included, the lack of flexibility in the working day, managing patient expectations, taking time off work at short notice and the ability to work part-time.
Motion of glossy objects does not promote separation of lighting and surface colour
2017-01-01
The surface properties of an object, such as texture, glossiness or colour, provide important cues to its identity. However, the actual visual stimulus received by the eye is determined by both the properties of the object and the illumination. We tested whether operational colour constancy for glossy objects (the ability to distinguish changes in spectral reflectance of the object, from changes in the spectrum of the illumination) was affected by rotational motion of either the object or the light source. The different chromatic and geometric properties of the specular and diffuse reflections provide the basis for this discrimination, and we systematically varied specularity to control the available information. Observers viewed animations of isolated objects undergoing either lighting or surface-based spectral transformations accompanied by motion. By varying the axis of rotation, and surface patterning or geometry, we manipulated: (i) motion-related information about the scene, (ii) relative motion between the surface patterning and the specular reflection of the lighting, and (iii) image disruption caused by this motion. Despite large individual differences in performance with static stimuli, motion manipulations neither improved nor degraded performance. As motion significantly disrupts frame-by-frame low-level image statistics, we infer that operational constancy depends on a high-level scene interpretation, which is maintained in all conditions. PMID:29291113
The effect of spatial orientation on detecting motion trajectories in noise.
Pavan, Andrea; Casco, Clara; Mather, George; Bellacosa, Rosilari M; Cuturi, Luigi F; Campana, Gianluca
2011-09-15
A series of experiments investigated the extent to which the spatial orientation of a signal line affects discrimination of its trajectory from the random trajectories of background noise lines. The orientation of the signal line was either parallel (iso-) or orthogonal (ortho-) to its motion direction and it was identical in all respects to the noise (orientation, length and speed) except for its motion direction, rendering the signal line indistinguishable from the noise on a frame-to-frame basis. We found that discrimination of ortho-trajectories was generally better than iso-trajectories. Discrimination of ortho-trajectories was largely immune to the effects of spatial jitter in the trajectory, and to variations in step size and line-length. Discrimination of iso-trajectories was reliable provided that step-size was not too short and did not exceed line length, and that the trajectory was straight. The new result that trajectory discrimination in moving line elements is modulated by line orientation suggests that ortho- and iso-trajectory discrimination rely upon two distinct mechanisms: iso-motion discrimination involves a 'motion-streak' process that combines motion information with information about orientation parallel to the motion trajectory, while ortho-motion discrimination involves extended trajectory facilitation in a network of receptive fields with orthogonal orientation tuning. Copyright © 2011 Elsevier Ltd. All rights reserved.
Discrimination of animate and inanimate motion in 9-month-old infants: an ERP study.
Kaduk, Katharina; Elsner, Birgit; Reid, Vincent M
2013-10-01
Simple geometric shapes moving in a self-propelled manner, and violating Newtonian laws of motion by acting against gravitational forces tend to induce a judgement that an object is animate. Objects that change their motion only due to external causes are more likely judged as inanimate. How the developing brain is employed in the perception of animacy in early ontogeny is currently unknown. The aim of this study was to use ERP techniques to determine if the negative central component (Nc), a waveform related to attention allocation, was differentially affected when an infant observed animate or inanimate motion. Short animated movies comprising a marble moving along a marble run either in an animate or an inanimate manner were presented to 15 infants who were 9 months of age. The ERPs were time-locked to a still frame representing animate or inanimate motion that was displayed following each movie. We found that 9-month-olds are able to discriminate between animate and inanimate motion based on motion cues alone and most likely allocate more attentional resources to the inanimate motion. The present data contribute to our understanding of the animate-inanimate distinction and the Nc as a correlate of infant cognitive processing. Copyright © 2013 Elsevier Ltd. All rights reserved.
Global Motions of the Nuclear Pore Complex: Insights from Elastic Network Models
Lezon, Timothy R.; Sali, Andrej; Bahar, Ivet
2009-01-01
The nuclear pore complex (NPC) is the gate to the nucleus. Recent determination of the configuration of proteins in the yeast NPC at ∼5 nm resolution permits us to study the NPC global dynamics using coarse-grained structural models. We investigate these large-scale motions by using an extended elastic network model (ENM) formalism applied to several coarse-grained representations of the NPC. Two types of collective motions (global modes) are predicted by the ENMs to be intrinsically favored by the NPC architecture: global bending and extension/contraction from circular to elliptical shapes. These motions are shown to be robust against tested variations in the representation of the NPC, and are largely captured by a simple model of a toroid with axially varying mass density. We demonstrate that spoke multiplicity significantly affects the accessible number of symmetric low-energy modes of motion; the NPC-like toroidal structures composed of 8 spokes have access to highly cooperative symmetric motions that are inaccessible to toroids composed of 7 or 9 spokes. The analysis reveals modes of motion that may facilitate macromolecular transport through the NPC, consistent with previous experimental observations. PMID:19730674
Global motions of the nuclear pore complex: insights from elastic network models.
Lezon, Timothy R; Sali, Andrej; Bahar, Ivet
2009-09-01
The nuclear pore complex (NPC) is the gate to the nucleus. Recent determination of the configuration of proteins in the yeast NPC at approximately 5 nm resolution permits us to study the NPC global dynamics using coarse-grained structural models. We investigate these large-scale motions by using an extended elastic network model (ENM) formalism applied to several coarse-grained representations of the NPC. Two types of collective motions (global modes) are predicted by the ENMs to be intrinsically favored by the NPC architecture: global bending and extension/contraction from circular to elliptical shapes. These motions are shown to be robust against tested variations in the representation of the NPC, and are largely captured by a simple model of a toroid with axially varying mass density. We demonstrate that spoke multiplicity significantly affects the accessible number of symmetric low-energy modes of motion; the NPC-like toroidal structures composed of 8 spokes have access to highly cooperative symmetric motions that are inaccessible to toroids composed of 7 or 9 spokes. The analysis reveals modes of motion that may facilitate macromolecular transport through the NPC, consistent with previous experimental observations.
Modulation frequency as a cue for auditory speed perception.
Senna, Irene; Parise, Cesare V; Ernst, Marc O
2017-07-12
Unlike vision, the mechanisms underlying auditory motion perception are poorly understood. Here we describe an auditory motion illusion revealing a novel cue to auditory speed perception: the temporal frequency of amplitude modulation (AM-frequency), typical for rattling sounds. Naturally, corrugated objects sliding across each other generate rattling sounds whose AM-frequency tends to directly correlate with speed. We found that AM-frequency modulates auditory speed perception in a highly systematic fashion: moving sounds with higher AM-frequency are perceived as moving faster than sounds with lower AM-frequency. Even more interestingly, sounds with higher AM-frequency also induce stronger motion aftereffects. This reveals the existence of specialized neural mechanisms for auditory motion perception, which are sensitive to AM-frequency. Thus, in spatial hearing, the brain successfully capitalizes on the AM-frequency of rattling sounds to estimate the speed of moving objects. This tightly parallels previous findings in motion vision, where spatio-temporal frequency of moving displays systematically affects both speed perception and the magnitude of the motion aftereffects. Such an analogy with vision suggests that motion detection may rely on canonical computations, with similar neural mechanisms shared across the different modalities. © 2017 The Author(s).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hutchings, L J; Foxall, W; Rambo, J
2005-02-14
Yucca Mountain licensing will require estimation of ground motions from probabilistic seismic hazard analyses (PSHA) with annual probabilities of exceedance on the order of 10{sup -6} to 10{sup -7} per year or smaller, which correspond to much longer earthquake return periods than most previous PSHA studies. These long return periods for the Yucca Mountain PSHA result in estimates of ground motion that are extremely high ({approx} 10 g) and that are believed to be physically unrealizable. However, there is at present no generally accepted method to bound ground motions either by showing that the physical properties of materials cannot maintainmore » such extreme motions, or the energy release by the source for such large motions is physically impossible. The purpose of this feasibility study is to examine recorded ground motion and rock property data from nuclear explosions to determine its usefulness for studying the ground motion from extreme earthquakes. The premise is that nuclear explosions are an extreme energy density source, and that the recorded ground motion will provide useful information about the limits of ground motion from extreme earthquakes. The data were categorized by the source and rock properties, and evaluated as to what extent non-linearity in the material has affected the recordings. They also compiled existing results of non-linear dynamic modeling of the explosions carried out by LLNL and other institutions. They conducted an extensive literature review to outline current understanding of extreme ground motion. They also analyzed the data in terms of estimating maximum ground motions at Yucca Mountain.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hutchings, L H; Foxall, W; Rambo, J
2005-03-09
Yucca Mountain licensing will require estimation of ground motions from probabilistic seismic hazard analyses (PSHA) with annual probabilities of exceedance on the order of 10{sup -6} to 10{sup -7} per year or smaller, which correspond to much longer earthquake return periods than most previous PSHA studies. These long return periods for the Yucca Mountain PSHA result in estimates of ground motion that are extremely high ({approx} 10 g) and that are believed to be physically unrealizable. However, there is at present no generally accepted method to bound ground motions either by showing that the physical properties of materials cannot maintainmore » such extreme motions, or the energy release by the source for such large motions is physically impossible. The purpose of this feasibility study is to examine recorded ground motion and rock property data from nuclear explosions to determine its usefulness for studying the ground motion from extreme earthquakes. The premise is that nuclear explosions are an extreme energy density source, and that the recorded ground motion will provide useful information about the limits of ground motion from extreme earthquakes. The data were categorized by the source and rock properties, and evaluated as to what extent non-linearity in the material has affected the recordings. They also compiled existing results of non-linear dynamic modeling of the explosions carried out by LLNL and other institutions. They conducted an extensive literature review to outline current understanding of extreme ground motion. They also analyzed the data in terms of estimating maximum ground motions at Yucca Mountain.« less
NASA Astrophysics Data System (ADS)
Tang, Jing; Wang, Xinhui; Gao, Xiangzhen; Segars, W. Paul; Lodge, Martin A.; Rahmim, Arman
2017-06-01
ECG gated cardiac PET imaging measures functional parameters such as left ventricle (LV) ejection fraction (EF), providing diagnostic and prognostic information for management of patients with coronary artery disease (CAD). Respiratory motion degrades spatial resolution and affects the accuracy in measuring the LV volumes for EF calculation. The goal of this study is to systematically investigate the effect of respiratory motion correction on the estimation of end-diastolic volume (EDV), end-systolic volume (ESV), and EF, especially on the separation of normal and abnormal EFs. We developed a respiratory motion incorporated 4D PET image reconstruction technique which uses all gated-frame data to acquire a motion-suppressed image. Using the standard XCAT phantom and two individual-specific volunteer XCAT phantoms, we simulated dual-gated myocardial perfusion imaging data for normally and abnormally beating hearts. With and without respiratory motion correction, we measured the EDV, ESV, and EF from the cardiac-gated reconstructed images. For all the phantoms, the estimated volumes increased and the biases significantly reduced with motion correction compared with those without. Furthermore, the improvement of ESV measurement in the abnormally beating heart led to better separation of normal and abnormal EFs. The simulation study demonstrated the significant effect of respiratory motion correction on cardiac imaging data with motion amplitude as small as 0.7 cm. The larger the motion amplitude the more improvement respiratory motion correction brought about on the EF measurement. Using data-driven respiratory gating, we also demonstrated the effect of respiratory motion correction on estimating the above functional parameters from list mode patient data. Respiratory motion correction has been shown to improve the accuracy of EF measurement in clinical cardiac PET imaging.
Magallares, Alejandro; Benito de Valle, Pilar; Irles, Jose Antonio; Jauregui-Lobera, Ignacio
2014-10-27
Obesity represents a serious health issue affecting millions of people in Western industrialized countries. The severity of the medical problems it causes is paralleled by the fact that obesity has become a social stigma that affects the psychological health-related quality of life of individuals with weight problems. Our study, with 111 obese patients of a Spanish hospital, focused specifically on how overt and subtle discrimination is related to subjective well-being (affect balance and life satisfaction) and physical health-related quality of life. It was shown that overt (r = -.28, p < .01 with affect balance; r = -.26, p < .01 with life satisfaction) and subtle discrimination (r = -.28, p < .01 with affect balance; r = -.27, p < .01 with life satisfaction) were negatively linked with subjective well-being, and that there was a negative correlation between overt discrimination and physical health-related quality of life (r = -.26, p < .01). Additionally, it was found that overt discrimination was a mediator variable in the relationship between physical health-related quality of life and subjective well-being using the Baron and Kenny procedure. Finally, it is discussed the relationship between discrimination, subjective well-being and physical health-related quality of life in obese people.
NASA Astrophysics Data System (ADS)
Schwarz, A. J.; Leach, M. O.
2000-08-01
Magnetic resonance spectroscopic imaging (MRSI) studies in the abdomen or breast are acquired in the presence of respiratory motion. This modifies the point spread function (PSF) and hence the reconstructed spectra. We evaluated the quantitative effects of both periodic and aperiodic motion on spectra localized by MRSI. Artefactual signal changes, both the modification of native to a voxel and spurious signals arising elsewhere, depend primarily upon the motion amplitude relative to the voxel dimension. A similar dependence on motion amplitude was observed for simple harmonic motion (SHM), quasi-periodic motion and random displacements. No systematic dependence upon the period or initial phase of SHM or on the array size was found. There was also no significant variation with motion direction relative to the internal and external phase-encoding directions. In measured excursion ranges of 20 breast and abdominal tumours, 70% moved ≤ 5 mm, while 30% moved 6-23 mm. The diaphragm and fatty tissues in the gut typically moved ~ 15-20 mm. While tumour/organ excursions less than half the voxel dimension do not substantially affect native signals, the bleeding in of strong lipid signals will be problematic in 1H studies. MRSI studies in the abdomen, even of relatively well-anchored tumours, are thus likely to benefit from the addition of respiratory triggering or other motion compensation strategies.
Local collective motion analysis for multi-probe dynamic imaging and microrheology
NASA Astrophysics Data System (ADS)
Khan, Manas; Mason, Thomas G.
2016-08-01
Dynamical artifacts, such as mechanical drift, advection, and hydrodynamic flow, can adversely affect multi-probe dynamic imaging and passive particle-tracking microrheology experiments. Alternatively, active driving by molecular motors can cause interesting non-Brownian motion of probes in local regions. Existing drift-correction techniques, which require large ensembles of probes or fast temporal sampling, are inadequate for handling complex spatio-temporal drifts and non-Brownian motion of localized domains containing relatively few probes. Here, we report an analytical method based on local collective motion (LCM) analysis of as few as two probes for detecting the presence of non-Brownian motion and for accurately eliminating it to reveal the underlying Brownian motion. By calculating an ensemble-average, time-dependent, LCM mean square displacement (MSD) of two or more localized probes and comparing this MSD to constituent single-probe MSDs, we can identify temporal regimes during which either thermal or athermal motion dominates. Single-probe motion, when referenced relative to the moving frame attached to the multi-probe LCM trajectory, provides a true Brownian MSD after scaling by an appropriate correction factor that depends on the number of probes used in LCM analysis. We show that LCM analysis can be used to correct many different dynamical artifacts, including spatially varying drifts, gradient flows, cell motion, time-dependent drift, and temporally varying oscillatory advection, thereby offering a significant improvement over existing approaches.
Kandala, Sridhar; Nolan, Dan; Laumann, Timothy O.; Power, Jonathan D.; Adeyemo, Babatunde; Harms, Michael P.; Petersen, Steven E.; Barch, Deanna M.
2016-01-01
Abstract Like all resting-state functional connectivity data, the data from the Human Connectome Project (HCP) are adversely affected by structured noise artifacts arising from head motion and physiological processes. Functional connectivity estimates (Pearson's correlation coefficients) were inflated for high-motion time points and for high-motion participants. This inflation occurred across the brain, suggesting the presence of globally distributed artifacts. The degree of inflation was further increased for connections between nearby regions compared with distant regions, suggesting the presence of distance-dependent spatially specific artifacts. We evaluated several denoising methods: censoring high-motion time points, motion regression, the FMRIB independent component analysis-based X-noiseifier (FIX), and mean grayordinate time series regression (MGTR; as a proxy for global signal regression). The results suggest that FIX denoising reduced both types of artifacts, but left substantial global artifacts behind. MGTR significantly reduced global artifacts, but left substantial spatially specific artifacts behind. Censoring high-motion time points resulted in a small reduction of distance-dependent and global artifacts, eliminating neither type. All denoising strategies left differences between high- and low-motion participants, but only MGTR substantially reduced those differences. Ultimately, functional connectivity estimates from HCP data showed spatially specific and globally distributed artifacts, and the most effective approach to address both types of motion-correlated artifacts was a combination of FIX and MGTR. PMID:27571276
Chapter A. The Loma Prieta, California, Earthquake of October 17, 1989 - Strong Ground Motion
Borcherdt, Roger D.
1994-01-01
Strong ground motion generated by the Loma Prieta, Calif., earthquake (MS~7.1) of October 17, 1989, resulted in at least 63 deaths, more than 3,757 injuries, and damage estimated to exceed $5.9 billion. Strong ground motion severely damaged critical lifelines (freeway overpasses, bridges, and pipelines), caused severe damage to poorly constructed buildings, and induced a significant number of ground failures associated with liquefaction and landsliding. It also caused a significant proportion of the damage and loss of life at distances as far as 100 km from the epicenter. Consequently, understanding the characteristics of the strong ground motion associated with the earthquake is fundamental to understanding the earthquake's devastating impact on society. The papers assembled in this chapter address this problem. Damage to vulnerable structures from the earthquake varied substantially with the distance from the causative fault and the type of underlying geologic deposits. Most of the damage and loss of life occurred in areas underlain by 'soft soil'. Quantifying these effects is important for understanding the tragic concentrations of damage in such areas as Santa Cruz and the Marina and Embarcadero Districts of San Francisco, and the failures of the San Francisco-Oakland Bay Bridge and the Interstate Highway 880 overpass. Most importantly, understanding these effects is a necessary prerequisite for improving mitigation measures for larger earthquakes likely to occur much closer to densely urbanized areas in the San Francisco Bay region. The earthquake generated an especially important data set for understanding variations in the severity of strong ground motion. Instrumental strong-motion recordings were obtained at 131 sites located from about 6 to 175 km from the rupture zone. This set of recordings, the largest yet collected for an event of this size, was obtained from sites on various geologic deposits, including a unique set on 'soft soil' deposits (artificial fill and bay mud). These exceptional ground-motion data are used by the authors of the papers in this chapter to infer radiation characteristics of the earthquake source, identify dominant propagation characteristics of the Earth?s crust, quantify amplification characteristics of near-surface geologic deposits, develop general amplification factors for site-dependent building-code provisions, and revise earthquake-hazard assessments for the San Francisco Bay region. Interpretations of additional data recorded in well-instrumented buildings, dams, and freeway overpasses are provided in other chapters of this report.
Brownian motion of solitons in a Bose-Einstein condensate.
Aycock, Lauren M; Hurst, Hilary M; Efimkin, Dmitry K; Genkina, Dina; Lu, Hsin-I; Galitski, Victor M; Spielman, I B
2017-03-07
We observed and controlled the Brownian motion of solitons. We launched solitonic excitations in highly elongated [Formula: see text] Bose-Einstein condensates (BECs) and showed that a dilute background of impurity atoms in a different internal state dramatically affects the soliton. With no impurities and in one dimension (1D), these solitons would have an infinite lifetime, a consequence of integrability. In our experiment, the added impurities scatter off the much larger soliton, contributing to its Brownian motion and decreasing its lifetime. We describe the soliton's diffusive behavior using a quasi-1D scattering theory of impurity atoms interacting with a soliton, giving diffusion coefficients consistent with experiment.
Brownian motion of solitons in a Bose–Einstein condensate
Aycock, Lauren M.; Hurst, Hilary M.; Efimkin, Dmitry K.; Genkina, Dina; Lu, Hsin-I; Galitski, Victor M.; Spielman, I. B.
2017-01-01
We observed and controlled the Brownian motion of solitons. We launched solitonic excitations in highly elongated Rb87 Bose–Einstein condensates (BECs) and showed that a dilute background of impurity atoms in a different internal state dramatically affects the soliton. With no impurities and in one dimension (1D), these solitons would have an infinite lifetime, a consequence of integrability. In our experiment, the added impurities scatter off the much larger soliton, contributing to its Brownian motion and decreasing its lifetime. We describe the soliton’s diffusive behavior using a quasi-1D scattering theory of impurity atoms interacting with a soliton, giving diffusion coefficients consistent with experiment. PMID:28196896
Critical role of foreground stimuli in perceiving visually induced self-motion (vection).
Nakamura, S; Shimojo, S
1999-01-01
The effects of a foreground stimulus on vection (illusory perception of self-motion induced by a moving background stimulus) were examined in two experiments. The experiments reveal that the presentation of a foreground pattern with a moving background stimulus may affect vection. The foreground stimulus facilitated vection strength when it remained stationary or moved slowly in the opposite direction to that of the background stimulus. On the other hand, there was a strong inhibition of vection when the foreground stimulus moved slowly with, or quickly against, the background. These results suggest that foreground stimuli, as well as background stimuli, play an important role in perceiving self-motion.
[Motion control of moving mirror based on fixed-mirror adjustment in FTIR spectrometer].
Li, Zhong-bing; Xu, Xian-ze; Le, Yi; Xu, Feng-qiu; Li, Jun-wei
2012-08-01
The performance of the uniform motion of the moving mirror, which is the only constant motion part in FTIR spectrometer, and the performance of the alignment of the fixed mirror play a key role in FTIR spectrometer, and affect the interference effect and the quality of the spectrogram and may restrict the precision and resolution of the instrument directly. The present article focuses on the research on the uniform motion of the moving mirror and the alignment of the fixed mirror. In order to improve the FTIR spectrometer, the maglev support system was designed for the moving mirror and the phase detection technology was adopted to adjust the tilt angle between the moving mirror and the fixed mirror. This paper also introduces an improved fuzzy PID control algorithm to get the accurate speed of the moving mirror and realize the control strategy from both hardware design and algorithm. The results show that the development of the moving mirror motion control system gets sufficient accuracy and real-time, which can ensure the uniform motion of the moving mirror and the alignment of the fixed mirror.
Kim, Hyun K; Park, Jaehyun; Choi, Yeongcheol; Choe, Mungyeong
2018-05-01
This study aims to develop a motion sickness measurement index in a virtual reality (VR) environment. The VR market is in an early stage of market formation and technological development, and thus, research on the side effects of VR devices such as simulator motion sickness is lacking. In this study, we used the simulator sickness questionnaire (SSQ), which has been traditionally used for simulator motion sickness measurement. To measure the motion sickness in a VR environment, 24 users performed target selection tasks using a VR device. The SSQ was administered immediately after each task, and the order of work was determined using the Latin square design. The existing SSQ was revised to develop a VR sickness questionnaire, which is used as the measurement index in a VR environment. In addition, the target selection method and button size were found to be significant factors that affect motion sickness in a VR environment. The results of this study are expected to be used for measuring and designing simulator sickness using VR devices in future studies. Copyright © 2018 Elsevier Ltd. All rights reserved.
Neural dynamics of motion processing and speed discrimination.
Chey, J; Grossberg, S; Mingolla, E
1998-09-01
A neural network model of visual motion perception and speed discrimination is presented. The model shows how a distributed population code of speed tuning, that realizes a size-speed correlation, can be derived from the simplest mechanisms whereby activations of multiple spatially short-range filters of different size are transformed into speed-turned cell responses. These mechanisms use transient cell responses to moving stimuli, output thresholds that covary with filter size, and competition. These mechanisms are proposed to occur in the V1-->MT cortical processing stream. The model reproduces empirically derived speed discrimination curves and simulates data showing how visual speed perception and discrimination can be affected by stimulus contrast, duration, dot density and spatial frequency. Model motion mechanisms are analogous to mechanisms that have been used to model 3-D form and figure-ground perception. The model forms the front end of a larger motion processing system that has been used to simulate how global motion capture occurs, and how spatial attention is drawn to moving forms. It provides a computational foundation for an emerging neural theory of 3-D form and motion perception.
NASA Astrophysics Data System (ADS)
Jin, Zhibin; Pei, Shiling; Li, Xiaozhen; Liu, Hongyan; Qiang, Shizhong
2016-11-01
The running safety of railway vehicles on bridges can be negatively affected by earthquake events. This phenomenon has traditionally been investigated with only the lateral ground excitation component considered. This paper presented results from a numerical investigation on the contribution of vertical ground motion component to the derailment of vehicles on simply-supported bridges. A full nonlinear wheel-rail contact model was used in the investigation together with the Hertzian contact theory and nonlinear creepage theory, which allows the wheel to jump vertically and separate from the rail. The wheel-rail relative displacement was used as the criterion for derailment events. A total of 18 ground motion records were used in the analysis to account for the uncertainty of ground motions. The results showed that inclusion of vertical ground motion will likely increase the chance of derailment. It is recommended to include vertical ground motion component in earthquake induced derailment analysis to ensure conservative estimations. The derailment event on bridges was found to be more closely related to the deck acceleration rather than the ground acceleration.
Real-time motion analytics during brain MRI improve data quality and reduce costs.
Dosenbach, Nico U F; Koller, Jonathan M; Earl, Eric A; Miranda-Dominguez, Oscar; Klein, Rachel L; Van, Andrew N; Snyder, Abraham Z; Nagel, Bonnie J; Nigg, Joel T; Nguyen, Annie L; Wesevich, Victoria; Greene, Deanna J; Fair, Damien A
2017-11-01
Head motion systematically distorts clinical and research MRI data. Motion artifacts have biased findings from many structural and functional brain MRI studies. An effective way to remove motion artifacts is to exclude MRI data frames affected by head motion. However, such post-hoc frame censoring can lead to data loss rates of 50% or more in our pediatric patient cohorts. Hence, many scanner operators collect additional 'buffer data', an expensive practice that, by itself, does not guarantee sufficient high-quality MRI data for a given participant. Therefore, we developed an easy-to-setup, easy-to-use Framewise Integrated Real-time MRI Monitoring (FIRMM) software suite that provides scanner operators with head motion analytics in real-time, allowing them to scan each subject until the desired amount of low-movement data has been collected. Our analyses show that using FIRMM to identify the ideal scan time for each person can reduce total brain MRI scan times and associated costs by 50% or more. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Garcia-Fernandez, Mariano; Assatourians, Karen; Jimenez, Maria-Jose
2018-01-01
Extreme natural hazard events have the potential to cause significant disruption to critical infrastructure (CI) networks. Among them, earthquakes represent a major threat as sudden-onset events with limited, if any, capability of forecast, and high damage potential. In recent years, the increased exposure of interdependent systems has heightened concern, motivating the need for a framework for the management of these increased hazards. The seismic performance level and resilience of existing non-nuclear CIs can be analyzed by identifying the ground motion input values leading to failure of selected key elements. Main interest focuses on the ground motions exceeding the original design values, which should correspond to low probability occurrence. A seismic hazard methodology has been specifically developed to consider low-probability ground motions affecting elongated CI networks. The approach is based on Monte Carlo simulation, which allows for building long-duration synthetic earthquake catalogs to derive low-probability amplitudes. This approach does not affect the mean hazard values and allows obtaining a representation of maximum amplitudes that follow a general extreme-value distribution. This facilitates the analysis of the occurrence of extremes, i.e., very low probability of exceedance from unlikely combinations, for the development of, e.g., stress tests, among other applications. Following this methodology, extreme ground-motion scenarios have been developed for selected combinations of modeling inputs including seismic activity models (source model and magnitude-recurrence relationship), ground motion prediction equations (GMPE), hazard levels, and fractiles of extreme ground motion. The different results provide an overview of the effects of different hazard modeling inputs on the generated extreme motion hazard scenarios. This approach to seismic hazard is at the core of the risk analysis procedure developed and applied to European CI transport networks within the framework of the European-funded INFRARISK project. Such an operational seismic hazard framework can be used to provide insight in a timely manner to make informed risk management or regulating further decisions on the required level of detail or on the adoption of measures, the cost of which can be balanced against the benefits of the measures in question.
Stout, Jeffrey N; Tisdall, M Dylan; McDaniel, Patrick; Gagoski, Borjan; Bolar, Divya S; Grant, Patricia Ellen; Adalsteinsson, Elfar
2017-12-01
Subject motion may cause errors in estimates of blood T 2 when using the T 2 -relaxation under spin tagging (TRUST) technique on noncompliant subjects like neonates. By incorporating 3D volume navigators (vNavs) into the TRUST pulse sequence, independent measurements of motion during scanning permit evaluation of these errors. The effects of integrated vNavs on TRUST-based T 2 estimates were evaluated using simulations and in vivo subject data. Two subjects were scanned with the TRUST+vNav sequence during prescribed movements. Mean motion scores were derived from vNavs and TRUST images, along with a metric of exponential fit quality. Regression analysis was performed between T 2 estimates and mean motion scores. Also, motion scores were determined from independent neonatal scans. vNavs negligibly affected venous blood T 2 estimates and better detected subject motion than fit quality metrics. Regression analysis showed that T 2 is biased upward by 4.1 ms per 1 mm of mean motion score. During neonatal scans, mean motion scores of 0.6 to 2.0 mm were detected. Motion during TRUST causes an overestimate of T 2 , which suggests a cautious approach when comparing TRUST-based cerebral oxygenation measurements of noncompliant subjects. Magn Reson Med 78:2283-2289, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Smyth, Joshua M; Zawadzki, Matthew J; Juth, Vanessa; Sciamanna, Christopher N
2017-04-01
Global life satisfaction has been linked with long-term health advantages, yet how life satisfaction impacts the trajectory of long-term health is unclear. This paper examines one such possible mechanism-that greater life satisfaction confers momentary benefits in daily life that accumulate over time. A community sample of working adults (n = 115) completed a measure of life satisfaction and then three subsequent days of ecological momentary assessment surveys (6 times/day) measuring affect (i.e., emotional valence, arousal), and perceived stress, and also provided salivary cortisol samples. Multilevel models indicated that people with higher (vs. lower) levels of life satisfaction reported better momentary affect, less stress, marginally lower momentary levels and significantly altered diurnal slopes of cortisol. Findings suggest individuals with high global life satisfaction have advantageous daily experiences, providing initial evidence for potential mechanisms through which global life satisfaction may help explain long-term health benefits.
Embryonic Exposure to Valproic Acid Impairs Social Predispositions of Newly-Hatched Chicks.
Sgadò, Paola; Rosa-Salva, Orsola; Versace, Elisabetta; Vallortigara, Giorgio
2018-04-12
Biological predispositions to attend to visual cues, such as those associated with face-like stimuli or with biological motion, guide social behavior from the first moments of life and have been documented in human neonates, infant monkeys and domestic chicks. Impairments of social predispositions have been recently reported in neonates at high familial risk of Autism Spectrum Disorder (ASD). Using embryonic exposure to valproic acid (VPA), an anticonvulsant associated to increased risk of developing ASD, we modeled ASD behavioral deficits in domestic chicks. We then assessed their spontaneous social predispositions by comparing approach responses to a stimulus containing a face configuration, a stuffed hen, vs. a scrambled version of it. We found that this social predisposition was abolished in VPA-treated chicks, whereas experience-dependent mechanisms associated with filial imprinting were not affected. Our results suggest a specific effect of VPA on the development of biologically-predisposed social orienting mechanisms, opening new perspectives to investigate the neurobiological mechanisms involved in early ASD symptoms.
[Fetal bone and joint disorders].
Jakobovits, Akos
2008-12-21
The article discusses the physiology and pathology of fetal bone and joint development and functions. The bones provide static support for the body. The skull and the bones of spinal column encase the central and part of the peripheral nervous system. The ribs and the sternum shield the heart and the lungs, while the bones of the pelvis protect the intraabdominal organs. Pathological changes of these bony structures may impair the functions of the respective systems or internal organs. Movements of the bones are brought about by muscles. The deriving motions are facilitated by joints. Bony anomalies of the extremities limit their effective functions. Apart from skeletal and joint abnormalities, akinesia may also be caused by neurological, muscular and skin diseases that secondarily affect the functions of bones and joints. Such pathological changes may lead to various degrees of physical disability and even to death. Some of the mentioned anomalies are recognizable in utero by ultrasound. The diagnosis may serve as medical indication for abortion in those instances when the identified abnormality is incompatible with independent life.
3D optical imagery for motion compensation in a limb ultrasound system
NASA Astrophysics Data System (ADS)
Ranger, Bryan J.; Feigin, Micha; Zhang, Xiang; Mireault, Al; Raskar, Ramesh; Herr, Hugh M.; Anthony, Brian W.
2016-04-01
Conventional processes for prosthetic socket fabrication are heavily subjective, often resulting in an interface to the human body that is neither comfortable nor completely functional. With nearly 100% of amputees reporting that they experience discomfort with the wearing of their prosthetic limb, designing an effective interface to the body can significantly affect quality of life and future health outcomes. Active research in medical imaging and biomechanical tissue modeling of residual limbs has led to significant advances in computer aided prosthetic socket design, demonstrating an interest in moving toward more quantifiable processes that are still patient-specific. In our work, medical ultrasonography is being pursued to acquire data that may quantify and improve the design process and fabrication of prosthetic sockets while greatly reducing cost compared to an MRI-based framework. This paper presents a prototype limb imaging system that uses a medical ultrasound probe, mounted to a mechanical positioning system and submerged in a water bath. The limb imaging is combined with three-dimensional optical imaging for motion compensation. Images are collected circumferentially around the limb and combined into cross-sectional axial image slices, resulting in a compound image that shows tissue distributions and anatomical boundaries similar to magnetic resonance imaging. In this paper we provide a progress update on our system development, along with preliminary results as we move toward full volumetric imaging of residual limbs for prosthetic socket design. This demonstrates a novel multi-modal approach to residual limb imaging.
Daily life activity routine discovery in hemiparetic rehabilitation patients using topic models.
Seiter, J; Derungs, A; Schuster-Amft, C; Amft, O; Tröster, G
2015-01-01
Monitoring natural behavior and activity routines of hemiparetic rehabilitation patients across the day can provide valuable progress information for therapists and patients and contribute to an optimized rehabilitation process. In particular, continuous patient monitoring could add type, frequency and duration of daily life activity routines and hence complement standard clinical scores that are assessed for particular tasks only. Machine learning methods have been applied to infer activity routines from sensor data. However, supervised methods require activity annotations to build recognition models and thus require extensive patient supervision. Discovery methods, including topic models could provide patient routine information and deal with variability in activity and movement performance across patients. Topic models have been used to discover characteristic activity routine patterns of healthy individuals using activity primitives recognized from supervised sensor data. Yet, the applicability of topic models for hemiparetic rehabilitation patients and techniques to derive activity primitives without supervision needs to be addressed. We investigate, 1) whether a topic model-based activity routine discovery framework can infer activity routines of rehabilitation patients from wearable motion sensor data. 2) We compare the performance of our topic model-based activity routine discovery using rule-based and clustering-based activity vocabulary. We analyze the activity routine discovery in a dataset recorded with 11 hemiparetic rehabilitation patients during up to ten full recording days per individual in an ambulatory daycare rehabilitation center using wearable motion sensors attached to both wrists and the non-affected thigh. We introduce and compare rule-based and clustering-based activity vocabulary to process statistical and frequency acceleration features to activity words. Activity words were used for activity routine pattern discovery using topic models based on Latent Dirichlet Allocation. Discovered activity routine patterns were then mapped to six categorized activity routines. Using the rule-based approach, activity routines could be discovered with an average accuracy of 76% across all patients. The rule-based approach outperformed clustering by 10% and showed less confusions for predicted activity routines. Topic models are suitable to discover daily life activity routines in hemiparetic rehabilitation patients without trained classifiers and activity annotations. Activity routines show characteristic patterns regarding activity primitives including body and extremity postures and movement. A patient-independent rule set can be derived. Including expert knowledge supports successful activity routine discovery over completely data-driven clustering.
Price, Marcella R; Bratton, Donna L; Klinnert, Mary D
2002-12-01
Quality of life has increased in popularity as an outcome measure in health research. However, the measurement of quality of life has been questioned on methodologic grounds, as it often shows little association with objective measures of disease status. For this report we studied the determinants of pediatric asthma caregiver report of quality of life and its relationship to disease burden. Ninety-eight children who were admitted to a Pediatric Day Program for an asthma evaluation were enrolled in an outcome study. A complete set of medical records for the 2-year period before and after the admission was collected and systematically coded for health care utilization. Using the Pediatric Asthma Caregiver's Quality of Life Questionnaire, data were collected at baseline, discharge, and year after the admission. Caregiver negative affect (anxiety and depression), measured with the Brief Symptom Inventory, was also collected at baseline and discharge. Caregiver report of quality of life was unrelated to health care utilization at baseline but instead was significantly related to baseline caregiver negative affect. A significant relationship between health care utilization and quality of life was present at followup. The Emotional Function scale from the quality of life measure can account for most of the relationship between quality of life and negative affect. Caregiver affect may have a considerable influence on report of quality of life. Understanding the individual characteristics of the respondent is important when using a quality of life instrument as an outcome measure.
Yu, Xiao-Guang; Li, Yuan-Qing; Zhu, Wei-Bin; Huang, Pei; Wang, Tong-Tong; Hu, Ning; Fu, Shao-Yun
2017-05-25
Melamine sponge, also known as nano-sponge, is widely used as an abrasive cleaner in our daily life. In this work, the fabrication of a wearable strain sensor for human motion detection is first demonstrated with a commercially available nano-sponge as a starting material. The key resistance sensitive material in the wearable strain sensor is obtained by the encapsulation of a carbonized nano-sponge (CNS) with silicone resin. The as-fabricated CNS/silicone sensor is highly sensitive to strain with a maximum gauge factor of 18.42. In addition, the CNS/silicone sensor exhibits a fast and reliable response to various cyclic loading within a strain range of 0-15% and a loading frequency range of 0.01-1 Hz. Finally, the CNS/silicone sensor as a wearable device for human motion detection including joint motion, eye blinking, blood pulse and breathing is demonstrated by attaching the sensor to the corresponding parts of the human body. In consideration of the simple fabrication technique, low material cost and excellent strain sensing performance, the CNS/silicone sensor is believed to have great potential in the next-generation of wearable devices for human motion detection.
Kang, Yue; Wang, Bo; Dai, Shuge; Liu, Guanlin; Pu, Yanping; Hu, Chenguo
2015-09-16
A folded elastic strip-based triboelectric nanogenerator (FS-TENG) made from two folded double-layer elastic strips of Al/PET and PTFE/PET can achieve multiple functions by low frequency mechanical motion. A single FS-TENG with strip width of 3 cm and length of 27 cm can generate a maximum output current, open-circuit voltage, and peak power of 55 μA, 840 V, and 7.33 mW at deformation frequency of 4 Hz with amplitude of 2.5 cm, respectively. This FS-TENG can work as a weight sensor due to its good elasticity. An integrated generator assembled by four FS-TENGs (IFS-TENG) can harvest the energy of human motion like flapping hands and walking steps. In addition, the IFS-TENG combined with electromagnetically induced electricity can achieve a completely self-driven doorbell with flashing lights. Moreover, a box-like generator integrated by four IFS-TENGs inside can work in horizontal or random motion modes and can be improved to harvest energy in all directions. This work promotes the research of completely self-driven systems and energy harvesting of human motion for applications in our daily life.
Brownian motion, old and new, and Irwin's role in my academic life
NASA Astrophysics Data System (ADS)
Lindenberg, Katja
2015-03-01
Irwin Oppenheim's early work on Langevin equations, master equations, and Brownian motion was one of the earliest and strongest reasons for my change of direction from my PhD work in condensed matter theory to my later and lifelong interest in Brownian motion and, more broadly, statistical mechanics. I will talk about some of my most recent work on subdiffusion, a form of anomalous diffusion that describes random motions in crowded or disordered media where motions are hindered by the medium. On a personal note, I knew Irwin for decades, from the time before he had a family (he was a sworn bachelor...until he met his wife) until shortly before his death. For many years, first alone and then with family, Irwin would spend some portion of the cold Boston winter in warm La Jolla, and we would always get together during these visits. For a period of a number of years we decided to take advantage of these visits to write the definitive text in traditional Thermodynamics. We did not make it past about 2/3 of the project, but it was a great learning experience for me while it lasted. Irwin's knowledge and understanding of the subject were breathtaking.
Deniz, M Engin; Işik, Erkan
2010-10-01
The purpose was to investigate positive and negative affect, life satisfaction, and coping with stress in relation to attachment styles. Undergraduate students (N=421) completed the Relationship Scales Questionnaire, the Positive and Negative Affect Scale, the Satisfaction With Life Scale, and the Coping with Stress Scale. Results indicated that secure attachment style was the unique predictor of positive affect while fearful and preoccupied attachment styles significantly predicted negative affect. Regarding life satisfaction, a positive correlation with secure attachment style and a negative correlation with fearful and preoccupied styles were seen. However, the unique predictor of life satisfaction was preoccupied attachment style. In terms of coping with stress, there was no significant association between attachment variables and avoidance coping style, but significant links were observed between problem-focused coping and dismissing, and fearful and preoccupied attachment styles.
Hydration dynamics promote bacterial coexistence on rough surfaces
Wang, Gang; Or, Dani
2013-01-01
Identification of mechanisms that promote and maintain the immense microbial diversity found in soil is a central challenge for contemporary microbial ecology. Quantitative tools for systematic integration of complex biophysical and trophic processes at spatial scales, relevant for individual cell interactions, are essential for making progress. We report a modeling study of competing bacterial populations cohabiting soil surfaces subjected to highly dynamic hydration conditions. The model explicitly tracks growth, motion and life histories of individual bacterial cells on surfaces spanning dynamic aqueous networks that shape heterogeneous nutrient fields. The range of hydration conditions that confer physical advantages for rapidly growing species and support competitive exclusion is surprisingly narrow. The rapid fragmentation of soil aqueous phase under most natural conditions suppresses bacterial growth and cell dispersion, thereby balancing conditions experienced by competing populations with diverse physiological traits. In addition, hydration fluctuations intensify localized interactions that promote coexistence through disproportional effects within densely populated regions during dry periods. Consequently, bacterial population dynamics is affected well beyond responses predicted from equivalent and uniform hydration conditions. New insights on hydration dynamics could be considered in future designs of soil bioremediation activities, affect longevity of dry food products, and advance basic understanding of bacterial diversity dynamics and its role in global biogeochemical cycles. PMID:23051694
Zooplankton intermittency and turbulence
NASA Astrophysics Data System (ADS)
Schmitt, François G.
2010-05-01
Planktonic organisms usually live in a turbulent world. Since marine turbulence is characterized by very high Reynolds numbers, it possesses very intermittent fluctuations which in turn affect marine life. We consider here such influence on zooplankton on 2 aspects. First we consider zooplankton motion in the lab. Many copepods display swimming abilities. More and more species have been recently recorded using normal or high speed cameras, and many trajectories have been extracted from these movies and are now available for analysis. These trajectories can be complex, stochastic, with random switching from low velocity to high velocity events and even jumps. These complex trajectories show that an adequate modeling is necessary to understand and characterize them. Here we review the results published in the literature on copepod trajectories. We discuss the random walk, Levy walk modeling and introduce also multifractal random walks. We discuss the way to discriminate between these different walks using experimental data. Stochastic simulations will be performed to illustrate the different families. Second, we consider zooplankton contact rates in the framework of intermittent turbulence. Intermittency may have influence on plankton contact rates. We consider the Particle Stokes number of copepods, in a intermediate dissipation range affected by intermittent fluctuations. We show that they may display preferential concentration effects, and we consider the influence on contact rates of this effect in the intermediate dissipation range.
ERIC Educational Resources Information Center
Riddick, Carol Cutler; Stewart, Debra Gonder
1994-01-01
Study compared black and white female retirees' (n=618) life satisfaction and determinants of life satisfaction. Survey results found differences between the groups in life satisfaction. Perceived health and leisure repertoire planning directly affected both groups' life satisfaction. Leisure activity directly affected whites. Leisure repertoire…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ali, I; Ahmad, S; Alsbou, N
Purpose: A motion algorithm was developed to extract actual length, CT-numbers and motion amplitude of a mobile target imaged with cone-beam-CT (CBCT) retrospective to image-reconstruction. Methods: The motion model considered a mobile target moving with a sinusoidal motion and employed three measurable parameters: apparent length, CT number level and gradient of a mobile target obtained from CBCT images to extract information about the actual length and CT number value of the stationary target and motion amplitude. The algorithm was verified experimentally with a mobile phantom setup that has three targets with different sizes manufactured from homogenous tissue-equivalent gel material embeddedmore » into a thorax phantom. The phantom moved sinusoidal in one-direction using eight amplitudes (0–20mm) and a frequency of 15-cycles-per-minute. The model required imaging parameters such as slice thickness, imaging time. Results: This motion algorithm extracted three unknown parameters: length of the target, CT-number-level, motion amplitude for a mobile target retrospective to CBCT image reconstruction. The algorithm relates three unknown parameters to measurable apparent length, CT-number-level and gradient for well-defined mobile targets obtained from CBCT images. The motion model agreed with measured apparent lengths which were dependent on actual length of the target and motion amplitude. The cumulative CT-number for a mobile target was dependent on CT-number-level of the stationary target and motion amplitude. The gradient of the CT-distribution of mobile target is dependent on the stationary CT-number-level, actual target length along the direction of motion, and motion amplitude. Motion frequency and phase did not affect the elongation and CT-number distributions of mobile targets when imaging time included several motion cycles. Conclusion: The motion algorithm developed in this study has potential applications in diagnostic CT imaging and radiotherapy to extract actual length, size and CT-numbers distorted by motion in CBCT imaging. The model provides further information about motion of the target.« less
Alsbou, Nesreen; Ahmad, Salahuddin; Ali, Imad
2016-05-17
A motion algorithm has been developed to extract length, CT number level and motion amplitude of a mobile target from cone-beam CT (CBCT) images. The algorithm uses three measurable parameters: Apparent length and blurred CT number distribution of a mobile target obtained from CBCT images to determine length, CT-number value of the stationary target, and motion amplitude. The predictions of this algorithm are tested with mobile targets having different well-known sizes that are made from tissue-equivalent gel which is inserted into a thorax phantom. The phantom moves sinusoidally in one-direction to simulate respiratory motion using eight amplitudes ranging 0-20 mm. Using this motion algorithm, three unknown parameters are extracted that include: Length of the target, CT number level, speed or motion amplitude for the mobile targets from CBCT images. The motion algorithm solves for the three unknown parameters using measured length, CT number level and gradient for a well-defined mobile target obtained from CBCT images. The motion model agrees with the measured lengths which are dependent on the target length and motion amplitude. The gradient of the CT number distribution of the mobile target is dependent on the stationary CT number level, the target length and motion amplitude. Motion frequency and phase do not affect the elongation and CT number distribution of the mobile target and could not be determined. A motion algorithm has been developed to extract three parameters that include length, CT number level and motion amplitude or speed of mobile targets directly from reconstructed CBCT images without prior knowledge of the stationary target parameters. This algorithm provides alternative to 4D-CBCT without requirement of motion tracking and sorting of the images into different breathing phases. The motion model developed here works well for tumors that have simple shapes, high contrast relative to surrounding tissues and move nearly in regular motion pattern that can be approximated with a simple sinusoidal function. This algorithm has potential applications in diagnostic CT imaging and radiotherapy in terms of motion management.
Predicting pedestrian flow: a methodology and a proof of concept based on real-life data.
Davidich, Maria; Köster, Gerta
2013-01-01
Building a reliable predictive model of pedestrian motion is very challenging: Ideally, such models should be based on observations made in both controlled experiments and in real-world environments. De facto, models are rarely based on real-world observations due to the lack of available data; instead, they are largely based on intuition and, at best, literature values and laboratory experiments. Such an approach is insufficient for reliable simulations of complex real-life scenarios: For instance, our analysis of pedestrian motion under natural conditions at a major German railway station reveals that the values for free-flow velocities and the flow-density relationship differ significantly from widely used literature values. It is thus necessary to calibrate and validate the model against relevant real-life data to make it capable of reproducing and predicting real-life scenarios. In this work we aim at constructing such realistic pedestrian stream simulation. Based on the analysis of real-life data, we present a methodology that identifies key parameters and interdependencies that enable us to properly calibrate the model. The success of the approach is demonstrated for a benchmark model, a cellular automaton. We show that the proposed approach significantly improves the reliability of the simulation and hence the potential prediction accuracy. The simulation is validated by comparing the local density evolution of the measured data to that of the simulated data. We find that for our model the most sensitive parameters are: the source-target distribution of the pedestrian trajectories, the schedule of pedestrian appearances in the scenario and the mean free-flow velocity. Our results emphasize the need for real-life data extraction and analysis to enable predictive simulations.
Effects of tether attachments on the Shuttle/Tethered Satellite System dynamics
NASA Technical Reports Server (NTRS)
Gresham, L. L.; Rupp, C. C.
1979-01-01
The dynamics of the Shuttle Tethered Satellite System are influenced by attaching the tether at some point other than the center-of-masses of the Shuttle and the subsatellite. At the Shuttle, the tether attachment is made at the end of a boom deployed out of the payload bay. This attachment noticeably affects retrieval dynamics of the satellite pendulous motion. At the satellite, the tether attachment is assumed to be made on the circumference of the satellite. This attachment greatly affects the attitude motion of the satellite about its own center-of-mass. Computer simulation results are presented showing the effects of the Shuttle boom in a three-dimensional model and the effects of satellite attachment in a planar model.
Computer simulations of ions in radio-frequency traps
NASA Technical Reports Server (NTRS)
Williams, A.; Prestage, J. D.; Maleki, L.; Djomehri, J.; Harabetian, E.
1990-01-01
The motion of ions in a trapped-ion frequency standard affects the stability of the standard. In order to study the motion and structures of large ion clouds in a radio-frequency (RF) trap, a computer simulation of the system that incorporates the effect of thermal excitation of the ions was developed. Results are presented from the simulation for cloud sizes up to 512 ions, emphasizing cloud structures in the low-temperature regime.
Propulsion by sinusoidal locomotion: A motion inspired by Caenorhabditis elegans
NASA Astrophysics Data System (ADS)
Ulrich, Xialing
Sinusoidal locomotion is commonly seen in snakes, fish, nematodes, or even the wings of some birds and insects. This doctoral thesis presents the study of sinusoidal locomotion of the nematode C. elegans in experiments and the application of the state-space airloads theory to the theoretical forces of sinusoidal motion. An original MATLAB program has been developed to analyze the video records of C. elegans' movement in different fluids, including Newtonian and non-Newtonian fluids. The experimental and numerical studies of swimming C. elegans has revealed three conclusions. First, though the amplitude and wavelength are varying with time, the motion of swimming C. elegans can still be viewed as sinusoidal locomotion with slips. The average normalized wavelength is a conserved character of the locomotion for both Newtonian and non-Newtonian fluids. Second, fluid viscosity affects the frequency but not the moving speed of C. elegans, while fluid elasticity affects the moving speed but not the frequency. Third, by the resistive force theory, for more elastic fluids the ratio of resistive coefficients becomes smaller. Inspired by the motion of C. elegans and other animals performing sinusoidal motion, we investigated the sinusoidal motion of a thin flexible wing in theory. Given the equation of the motion, we have derived the closed forms of propulsive force, lift and other generalized forces applying on the wing. We also calculated the power required to perform the motion, the power lost due to the shed vortices and the propulsive efficiency. These forces and powers are given as functions of reduced frequency k, dimensionless wavelength z, dimensionless amplitude A/b, and time. Our results show that a positive, time-averaged propulsive force is produced for all k>k0=pi/ z. At k=k0, which implies the moment when the moving speed of the wing is the same as the wave speed of its undulation, the motion reaches a steady state with all forces being zero. If there were no shed vorticity effects, the propulsive force would be zero at z = 0.569 and z = 1.3 for all k, and for a fixed k the wing would gain the optimal propulsive force when z = 0.82. With the effects of shed vorticity, the propulsive efficiency decreases from 1.0 to 0.5 as k goes to infinity, and the propulsive efficiency increases almost in a linear relationship with k0.
Motion correction options in PET/MRI.
Catana, Ciprian
2015-05-01
Subject motion is unavoidable in clinical and research imaging studies. Breathing is the most important source of motion in whole-body PET and MRI studies, affecting not only thoracic organs but also those in the upper and even lower abdomen. The motion related to the pumping action of the heart is obviously relevant in high-resolution cardiac studies. These two sources of motion are periodic and predictable, at least to a first approximation, which means certain techniques can be used to control the motion (eg, by acquiring the data when the organ of interest is relatively at rest). Additionally, nonperiodic and unpredictable motion can also occur during the scan. One obvious limitation of methods relying on external devices (eg, respiratory bellows or the electrocardiogram signal to monitor the respiratory or cardiac cycle, respectively) to trigger or gate the data acquisition is that the complex motion of internal organs cannot be fully characterized. However, detailed information can be obtained using either the PET or MRI data (or both) allowing the more complete characterization of the motion field so that a motion model can be built. Such a model and the information derived from simple external devices can be used to minimize the effects of motion on the collected data. In the ideal case, all the events recorded during the PET scan would be used to generate a motion-free or corrected PET image. The detailed motion field can be used for this purpose by applying it to the PET data before, during, or after the image reconstruction. Integrating all these methods for motion control, characterization, and correction into a workflow that can be used for routine clinical studies is challenging but could potentially be extremely valuable given the improvement in image quality and reduction of motion-related image artifacts. Copyright © 2015 Elsevier Inc. All rights reserved.
Effect of multilayer high-compression bandaging on ankle range of motion and oxygen cost of walking
Roaldsen, K S; Elfving, B; Stanghelle, J K; Mattsson, E
2012-01-01
Objective To evaluate the effects of multilayer high-compression bandaging on ankle range of motion, oxygen consumption and subjective walking ability in healthy subjects. Method A volunteer sample of 22 healthy subjects (10 women and 12 men; aged 67 [63–83] years) were studied. The intervention included treadmill-walking at self-selected speed with and without multilayer high-compression bandaging (Proforeº), randomly selected. The primary outcome variables were ankle range of motion, oxygen consumption and subjective walking ability. Results Total ankle range of motion decreased 4% with compression. No change in oxygen cost of walking was observed. Less than half the subjects reported that walking-shoe comfort or walking distance was negatively affected. Conclusion Ankle range of motion decreased with compression but could probably be counteracted with a regular exercise programme. There were no indications that walking with compression was more exhausting than walking without. Appropriate walking shoes could seem important to secure gait efficiency when using compression garments. PMID:21810941
Mapping cardiogenic oscillations using synchrotron-based phase contrast CT imaging
NASA Astrophysics Data System (ADS)
Thurgood, Jordan; Dubsky, Stephen; Siu, Karen K. W.; Wallace, Megan; Siew, Melissa; Hooper, Stuart; Fouras, Andreas
2012-10-01
In many animals, including humans, the lungs encase the majority of the heart thus the motion of each organ affects the other. The effects of the motion of the heart on the lungs potentially provides information with regards to both lung and heart health. We present a novel technique that is capable of measuring the effect of the heart on the surrounding lung tissue through the use of advanced synchrotron imaging techniques and recently developed X-ray velocimetry methods. This technique generates 2D frequency response maps of the lung tissue motion at multiple projection angles from projection X-ray images. These frequency response maps are subsequently used to generate 3D reconstructions of the lung tissue exhibiting motion at the frequency of ventilation and the lung tissue exhibiting motion at the frequency of the heart. This technique has a combined spatial and temporal resolution sufficient to observe the dynamic and complex 3D nature of lung-heart interactions.
Motion-oriented 3D analysis of body measurements
NASA Astrophysics Data System (ADS)
Loercher, C.; Morlock, S.; Schenk, A.
2017-10-01
The aim of this project is to develop an ergonomically based and motion-oriented size system. New concepts are required in order to be able to deal competently with complex requirements of function-oriented workwear and personal protective equipment (PPE). Body dimensions change through movement, which are basis for motion optimized clothing development. This affects fit and ergonomic comfort. The situation has to be fundamentally researched in order to derive well-founded anthropometric body data, taking into account kinematic requirements of humans and to define functional dimensions for clothing industry. Research focus shall be on ergonomic design of workwear and PPE. There are huge differences in body forms, proportions and muscle manifestations between genders. An improved basic knowledge can be provided as a result, supporting development as well as sales of motion-oriented clothing with perfect fit for garment manufacturers.
NASA Astrophysics Data System (ADS)
Shao, Xinxing; Zhu, Feipeng; Su, Zhilong; Dai, Xiangjun; Chen, Zhenning; He, Xiaoyuan
2018-03-01
The strain errors in stereo-digital image correlation (DIC) due to camera calibration were investigated using precisely controlled numerical experiments and real experiments. Three-dimensional rigid body motion tests were conducted to examine the effects of camera calibration on the measured results. For a fully accurate calibration, rigid body motion causes negligible strain errors. However, for inaccurately calibrated camera parameters and a short working distance, rigid body motion will lead to more than 50-μɛ strain errors, which significantly affects the measurement. In practical measurements, it is impossible to obtain a fully accurate calibration; therefore, considerable attention should be focused on attempting to avoid these types of errors, especially for high-accuracy strain measurements. It is necessary to avoid large rigid body motions in both two-dimensional DIC and stereo-DIC.
Field signature for apparently superluminal particle motion
NASA Astrophysics Data System (ADS)
Land, Martin
2015-05-01
In the context of Stueckelberg's covariant symplectic mechanics, Horwitz and Aharonovich [1] have proposed a simple mechanism by which a particle traveling below light speed almost everywhere may exhibit a transit time that suggests superluminal motion. This mechanism, which requires precise measurement of the particle velocity, involves a subtle perturbation affecting the particle's recorded time coordinate caused by virtual pair processes. The Stueckelberg framework is particularly well suited to such problems, because it permits pair creation/annihilation at the classical level. In this paper, we study a trajectory of the type proposed by Horwitz and Aharonovich, and derive the Maxwell 4-vector potential associated with the motion. We show that the resulting fields carry a signature associated with the apparent superluminal motion, providing an independent test for the mechanism that does not require direct observation of the trajectory, except at the detector.
Aati, Opetaia; Taylor, William J; Horne, Anne; Dalbeth, Nicola
2014-08-01
Although tophi are known to affect physical function, the impact of tophi on the lives of people with gout has not been explored in detail. The aim of this qualitative study was to understand the experience of people living with tophaceous gout, as the first step to developing a patient-reported Tophus Impact Questionnaire. Twenty-five people with tophaceous gout (22 men; median age, 66 years; median gout disease duration, 26 years) participated in semistructured interviews that explored their experiences and perceptions of tophi. Interviews were recorded and transcribed. The transcripts were analyzed and coded to identify themes using content analysis. Three major interrelated themes arose from the interviews. The first theme was functional impact affecting body structures and functions (causing pain, restricted joint range of motion and deformity, and complications), and causing activity limitation and participation restriction (affecting day-to-day activities, leisure activities, employment participation, and family participation). The second theme was psychological impact including low self-esteem, embarrassment, resignation, but also optimism. The third theme was the lack of impact in some participants. Gouty tophi can have an important impact on many aspects of the patient's life. In addition to the impact of tophi on physical function, tophi may also influence social and psychological functioning. Capturing these aspects of the patient experience will be important in the development of a patient-reported outcome measure of tophus burden.
Near-surface wave velocity structure of Faial (Azores - Portugal) Island for site effect studies
NASA Astrophysics Data System (ADS)
Borges, José; Neves, Samuel; Caldeira, Bento; Bezzeghoud, Mourad; Carvalho, João; Carvalho, Alexandra
2015-04-01
Throughout history, the life of the Azorean people has been marked by earthquakes that have had different effects depending on their proximity and magnitude. This seismic activity, which may have volcanic or tectonic origins, has affected the population of these islands by destroying infrastructure and claiming lives. The social and economic impacts of these phenomena are enormous. The last significant event affecting the Azores (Portugal) was the July 1998 Mw=6.2 earthquake causing major destruction affecting more than 5000 people, causing 8 deaths, 150 persons injured and 1500 homeless. Ground motion simulations are mainly based on source characteristics and are heavily dependent on the medium, which is still poorly understood. Subsurface soil condition can amplify the seismic waves, so, for seismic response analysis, it is necessary to know the shallow soil properties and its spatial variability. For this purpose, we applied P and S-wave refraction, Multichannel Analysis of Surface Waves (MASW) to characterize shear wave velocity at different sites in the Faial Island, in particular, in sites where already occurred amplification. Ambient vibrations can also be used to estimate physical properties of the shallower geological formations. With this goal, the obtained velocity models were confirmed by comparison between real H/V curves with synthetic ones. We concluded that the anomalous intensities observed in some sites are strongly related to thick layers of soft sediments of pyroclastic deposits produced by old volcanic eruptions occurred in the Faial Island.
Cervical range of motion discriminates between asymptomatic persons and those with whiplash.
Dall'Alba, P T; Sterling, M M; Treleaven, J M; Edwards, S L; Jull, G A
2001-10-01
A comparative study of cervical range of motion in asymptomatic persons and those with whiplash. To compare the primary and conjunct ranges of motion of the cervical spine in asymptomatic persons and those with persistent whiplash-associated disorders, and to investigate the ability of these measures of range of motion to discriminate between the groups. Evidence that range of motion is an effective indicator of physical impairment in the cervical spine is not conclusive. Few studies have evaluated the ability to discriminate between asymptomatic persons and those with whiplash on the basis of range of motion or compared three-dimensional in vivo measures of range of motion in asymptomatic persons and those with whiplash-associated disorders. The study participants were 89 asymptomatic volunteers (41 men, 48 women; mean age 39.2 years) and 114 patients with persistent whiplash-associated disorders (22 men, 93 women; mean age 37.2 years) referred to a whiplash research unit for assessment of their cervical region. Range of cervical motion was measured in three dimensions with a computerized, electromagnetic, motion-tracking device. The movements assessed were flexion, extension, left and right lateral flexion, and left and right rotation. Range of motion was reduced in all primary movements in patients with persistent whiplash-associated disorder. Sagittal plane movements were proportionally the most affected. On the basis of primary and conjunct range of motion, age, and gender, 90.3% of study participants could be correctly categorized as asymptomatic or as having whiplash (sensitivity 86.2%, specificity 95.3%). Range of motion was capable of discriminating between asymptomatic persons and those with persistent whiplash-associated disorders.
An EMG-Based Control for an Upper-Limb Power-Assist Exoskeleton Robot.
Kiguchi, K; Hayashi, Y
2012-08-01
Many kinds of power-assist robots have been developed in order to assist self-rehabilitation and/or daily life motions of physically weak persons. Several kinds of control methods have been proposed to control the power-assist robots according to user's motion intention. In this paper, an electromyogram (EMG)-based impedance control method for an upper-limb power-assist exoskeleton robot is proposed to control the robot in accordance with the user's motion intention. The proposed method is simple, easy to design, humanlike, and adaptable to any user. A neurofuzzy matrix modifier is applied to make the controller adaptable to any users. Not only the characteristics of EMG signals but also the characteristics of human body are taken into account in the proposed method. The effectiveness of the proposed method was evaluated by the experiments.
NASA Technical Reports Server (NTRS)
Jackson, Mariea Dunn; Dischinger, Charles; Stambolian, Damon; Henderson, Gena
2012-01-01
Spacecraft and launch vehicle ground processing activities require a variety of unique human activities. These activities are being documented in a Primitive motion capture library. The Library will be used by the human factors engineering in the future to infuse real to life human activities into the CAD models to verify ground systems human factors requirements. As the Primitive models are being developed for the library the project has selected several current human factors issues to be addressed for the SLS and Orion launch systems. This paper explains how the Motion Capture of unique ground systems activities are being used to verify the human factors analysis requirements for ground system used to process the STS and Orion vehicles, and how the primitive models will be applied to future spacecraft and launch vehicle processing.
Postures and Motions Library Development for Verification of Ground Crew Human Factors Requirements
NASA Technical Reports Server (NTRS)
Stambolian, Damon; Henderson, Gena; Jackson, Mariea Dunn; Dischinger, Charles
2013-01-01
Spacecraft and launch vehicle ground processing activities require a variety of unique human activities. These activities are being documented in a primitive motion capture library. The library will be used by human factors engineering analysts to infuse real to life human activities into the CAD models to verify ground systems human factors requirements. As the primitive models are being developed for the library, the project has selected several current human factors issues to be addressed for the Space Launch System (SLS) and Orion launch systems. This paper explains how the motion capture of unique ground systems activities is being used to verify the human factors engineering requirements for ground systems used to process the SLS and Orion vehicles, and how the primitive models will be applied to future spacecraft and launch vehicle processing.
NASA Astrophysics Data System (ADS)
Lee, K. C.
2013-02-01
Multifractional Brownian motions have become popular as flexible models in describing real-life signals of high-frequency features in geoscience, microeconomics, and turbulence, to name a few. The time-changing Hurst exponent, which describes regularity levels depending on time measurements, and variance, which relates to an energy level, are two parameters that characterize multifractional Brownian motions. This research suggests a combined method of estimating the time-changing Hurst exponent and variance using the local variation of sampled paths of signals. The method consists of two phases: initially estimating global variance and then accurately estimating the time-changing Hurst exponent. A simulation study shows its performance in estimation of the parameters. The proposed method is applied to characterization of atmospheric stability in which descriptive statistics from the estimated time-changing Hurst exponent and variance classify stable atmosphere flows from unstable ones.
Sailer, Uta; Rosenberg, Patricia; Nima, Ali Al; Gamble, Amelie; Gärling, Tommy; Archer, Trevor; Garcia, Danilo
2014-01-01
Background. Previous studies have established a link between how people relate to their past, present, and future (i.e., time perspective) and subjective well-being (i.e., life satisfaction, positive and negative affect). Time perspective comprises five dimensions: Past Positive, Past Negative, Present Hedonistic, Present Fatalistic, and Future. Life satisfaction can also be evaluated in relation to different time frames. Moreover, approach related positive affect is associated to a different concept of well-being labeled psychological well-being. In the present study we extend previous findings by investigating the effect of time perspective on the time frame of evaluations of life satisfaction (past, present, future) and by investigating the relationship between time perspective and psychological well-being. Method. Questionnaires on time perspective (Zimbardo's Time Perspective Inventory), temporal life satisfaction (Temporal Satisfaction with Life Scale), affect (Positive Affect and Negative Affect Schedule), and psychological well-being (Scales of Psychological Well-Being-short version) were answered by 453 individuals. Two different structural equation models were tested, one of the relationship between time perspective and temporal life satisfaction, and the other of the relationship between time perspective, affect and psychological well-being. Results. Time perspective affected life satisfaction depending on the time scale on which it was evaluated-memory of a negative past influenced life satisfaction in all time frames, and a positive view of the past influenced both past and future life satisfaction. Moreover, less rumination about past negative events (i.e., low score on Past Negative), the tendency to take risks in the present to achieve happy feelings and/or avoid boredom (i.e., high scores on Present Hedonistic), and a less hopeless and pessimistic view about the present (low scores on Present Fatalistic) were associated with higher levels of psychological well-being and positive affect. These same time perspective dimensions were associated with lower levels of negative affect. The Future time perspective dimension (i.e., approaching life with self-control, punctuality, and planning for the future) was associated with both psychological well-being and positive affect. Conclusions. High levels of both subjective and psychological well-being are related to a happier and a less sinister past, a more hedonistic and less fatalistic present, as well as to a more structured future.
Sailer, Uta; Rosenberg, Patricia; Nima, Ali Al; Gamble, Amelie; Gärling, Tommy; Archer, Trevor
2014-01-01
Background. Previous studies have established a link between how people relate to their past, present, and future (i.e., time perspective) and subjective well-being (i.e., life satisfaction, positive and negative affect). Time perspective comprises five dimensions: Past Positive, Past Negative, Present Hedonistic, Present Fatalistic, and Future. Life satisfaction can also be evaluated in relation to different time frames. Moreover, approach related positive affect is associated to a different concept of well-being labeled psychological well-being. In the present study we extend previous findings by investigating the effect of time perspective on the time frame of evaluations of life satisfaction (past, present, future) and by investigating the relationship between time perspective and psychological well-being. Method. Questionnaires on time perspective (Zimbardo’s Time Perspective Inventory), temporal life satisfaction (Temporal Satisfaction with Life Scale), affect (Positive Affect and Negative Affect Schedule), and psychological well-being (Scales of Psychological Well-Being—short version) were answered by 453 individuals. Two different structural equation models were tested, one of the relationship between time perspective and temporal life satisfaction, and the other of the relationship between time perspective, affect and psychological well-being. Results. Time perspective affected life satisfaction depending on the time scale on which it was evaluated—memory of a negative past influenced life satisfaction in all time frames, and a positive view of the past influenced both past and future life satisfaction. Moreover, less rumination about past negative events (i.e., low score on Past Negative), the tendency to take risks in the present to achieve happy feelings and/or avoid boredom (i.e., high scores on Present Hedonistic), and a less hopeless and pessimistic view about the present (low scores on Present Fatalistic) were associated with higher levels of psychological well-being and positive affect. These same time perspective dimensions were associated with lower levels of negative affect. The Future time perspective dimension (i.e., approaching life with self-control, punctuality, and planning for the future) was associated with both psychological well-being and positive affect. Conclusions. High levels of both subjective and psychological well-being are related to a happier and a less sinister past, a more hedonistic and less fatalistic present, as well as to a more structured future. PMID:24688878
Wang, Zun-Rong; Wang, Ping; Xing, Liang; Mei, Li-Ping; Zhao, Jun; Zhang, Tong
2017-11-01
Virtual reality is nowadays used to facilitate motor recovery in stroke patients. Most virtual reality studies have involved chronic stroke patients; however, brain plasticity remains good in acute and subacute patients. Most virtual reality systems are only applicable to the proximal upper limbs (arms) because of the limitations of their capture systems. Nevertheless, the functional recovery of an affected hand is most difficult in the case of hemiparesis rehabilitation after a stroke. The recently developed Leap Motion controller can track the fine movements of both hands and fingers. Therefore, the present study explored the effects of a Leap Motion-based virtual reality system on subacute stroke. Twenty-six subacute stroke patients were assigned to an experimental group that received virtual reality training along with conventional occupational rehabilitation, and a control group that only received conventional rehabilitation. The Wolf motor function test (WMFT) was used to assess the motor function of the affected upper limb; functional magnetic resonance imaging was used to measure the cortical activation. After four weeks of treatment, the motor functions of the affected upper limbs were significantly improved in all the patients, with the improvement in the experimental group being significantly better than in the control group. The action performance time in the WMFT significantly decreased in the experimental group. Furthermore, the activation intensity and the laterality index of the contralateral primary sensorimotor cortex increased in both the experimental and control groups. These results confirmed that Leap Motion-based virtual reality training was a promising and feasible supplementary rehabilitation intervention, could facilitate the recovery of motor functions in subacute stroke patients. The study has been registered in the Chinese Clinical Trial Registry (registration number: ChiCTR-OCH-12002238).
Wang, Zun-rong; Wang, Ping; Xing, Liang; Mei, Li-ping; Zhao, Jun; Zhang, Tong
2017-01-01
Virtual reality is nowadays used to facilitate motor recovery in stroke patients. Most virtual reality studies have involved chronic stroke patients; however, brain plasticity remains good in acute and subacute patients. Most virtual reality systems are only applicable to the proximal upper limbs (arms) because of the limitations of their capture systems. Nevertheless, the functional recovery of an affected hand is most difficult in the case of hemiparesis rehabilitation after a stroke. The recently developed Leap Motion controller can track the fine movements of both hands and fingers. Therefore, the present study explored the effects of a Leap Motion-based virtual reality system on subacute stroke. Twenty-six subacute stroke patients were assigned to an experimental group that received virtual reality training along with conventional occupational rehabilitation, and a control group that only received conventional rehabilitation. The Wolf motor function test (WMFT) was used to assess the motor function of the affected upper limb; functional magnetic resonance imaging was used to measure the cortical activation. After four weeks of treatment, the motor functions of the affected upper limbs were significantly improved in all the patients, with the improvement in the experimental group being significantly better than in the control group. The action performance time in the WMFT significantly decreased in the experimental group. Furthermore, the activation intensity and the laterality index of the contralateral primary sensorimotor cortex increased in both the experimental and control groups. These results confirmed that Leap Motion-based virtual reality training was a promising and feasible supplementary rehabilitation intervention, could facilitate the recovery of motor functions in subacute stroke patients. The study has been registered in the Chinese Clinical Trial Registry (registration number: ChiCTR-OCH-12002238). PMID:29239328
Hand function and quality of life before and after fasciectomy for Dupuytren contracture.
Engstrand, Christina; Krevers, Barbro; Nylander, Göran; Kvist, Joanna
2014-07-01
To describe changes in joint motion, sensibility, and scar pliability and to investigate the patients' expectations, self-reported recovery, and satisfaction with hand function, disability, and quality of life after surgery and hand therapy for Dupuytren disease. This prospective cohort study collected measurements before surgery and 3, 6, and 12 months after surgery and hand therapy. Ninety patients with total active extension deficits of 60° or more from Dupuytren contracture were included. Outcomes measures were range of motion; sensibility; scar pliability; self-reported outcomes on expectations, recovery, and satisfaction with hand function; Disabilities of the Arm, Shoulder, and Hand scores; safety and social issues of hand function; physical activity habits; and quality of life with the Euroqol. The extension deficit decreased, and there was a transient decrease in active finger flexion during the first year after surgery. Sensibility remained unaffected. Generally, patients with surgery on multiple fingers had worse scar pliability. The majority of the patients had their expectations met, and at 6 months, 32% considered hand function as fully recovered, and 73% were satisfied with their hand function. Fear of hurting the hand and worry about not trusting the hand function were of greatest concern among safety and social issues. The Disability of the Arm, Shoulder, and Hand score and the Euroqol improved over time. After surgery and hand therapy, disability decreased independent of single or multiple operated fingers. The total active finger extension improved enough for the patients to reach a functional range of motion despite an impairment of active finger flexion still present 12 months after treatment. Therapeutic IV. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Tefner, Ildikó Katalin; Kovács, Csaba; Gaál, Ramóna; Koroknai, András; Horváth, Remény; Badruddin, Rakib Mohammed; Borbély, Ildikó; Nagy, Katalin; Bender, Tamás
2015-06-01
The effects of balneotherapy on chronic shoulder pain were studied. In this single-blind, randomized, follow-up study involving 46 patients with chronic shoulder pain, one group of patients received physiotherapy--exercise and transcutaneous electrical nerve stimulation--and the other group received balneotherapy in addition to physiotherapy for 4 weeks on 15 occasions. The following parameters were recorded before treatment (at week 0) and after treatment (at weeks 4, 7, and 13): Shoulder Pain and Disability Index (SPADI), the Short Form (36) Health Survey (SF-36) and EuroQuol-5D (EQ-5D) quality of life questionnaires, pain at rest and on movement on the visual analog scale (VAS), and active and passive range of motion. The SPADI pain, function, and total scores and the VAS scores at rest and on movement significantly improved in both groups after treatments. A greater improvement was observed in the balneotherapy group compared to the control group; regarding some parameters (VAS score on movement and SPADI function score at visit 2; VAS score at rest at visits 3 and 4), the difference between the groups was significant. The improvement of SF-36 and EQ-5D quality of life scores and the active range of motion was more pronounced in the balneotherapy group, the difference between the groups was not significant, except for EQ-5D at visit 2. Improvement of passive range of motion was not significant. Balneotherapy may have a beneficial effect on the clinical parameters and quality of life of patients with chronic shoulder pain. The number of patients should be increased.
The nature of water within bacterial spores: protecting life in extreme environments
NASA Astrophysics Data System (ADS)
Rice, Charles V.; Friedline, Anthony; Johnson, Karen; Zachariah, Malcolm M.; Thomas, Kieth J., III
2011-10-01
The bacterial spore is a formidable container of life, protecting the vital contents from chemical attack, antimicrobial agents, heat damage, UV light degradation, and water dehydration. The exact role of the spore components remains in dispute. Nevertheless, water molecules are important in each of these processes. The physical state of water within the bacterial spore has been investigated since the early 1930's. The water is found two states, free or bound, in two different areas, core and non-core. It is established that free water is accessible to diffuse and exchange with deuterated water and that the diffusible water can access all areas of the spore. The presence of bound water has come under recent scrutiny and has been suggested the water within the core is mobile, rather than bound, based on the analysis of deuterium relaxation rates. Using an alternate method, deuterium quadrupole-echo spectroscopy, we are able to distinguish between mobile and immobile water molecules. In the absence of rapid motion, the deuterium spectrum of D2O is dominated by a broad line, whose line shape is used as a characteristic descriptor of molecular motion. The deuterium spectrum of bacterial spores reveals three distinct features: the broad peak of immobilized water, a narrow line of water in rapid motion, and a signal of intermediate width. This third signal is assigned this peak from partially deuterated proteins with the spore in which N-H groups have undergone exchange with water deuterons to form N-D species. As a result of these observations, the nature of water within the spore requires additional explanation to understand how the spore and its water preserve life.
Two-year-olds with autism orient to non-social contingencies rather than biological motion.
Klin, Ami; Lin, David J; Gorrindo, Phillip; Ramsay, Gordon; Jones, Warren
2009-05-14
Typically developing human infants preferentially attend to biological motion within the first days of life. This ability is highly conserved across species and is believed to be critical for filial attachment and for detection of predators. The neural underpinnings of biological motion perception are overlapping with brain regions involved in perception of basic social signals such as facial expression and gaze direction, and preferential attention to biological motion is seen as a precursor to the capacity for attributing intentions to others. However, in a serendipitous observation, we recently found that an infant with autism failed to recognize point-light displays of biological motion, but was instead highly sensitive to the presence of a non-social, physical contingency that occurred within the stimuli by chance. This observation raised the possibility that perception of biological motion may be altered in children with autism from a very early age, with cascading consequences for both social development and the lifelong impairments in social interaction that are a hallmark of autism spectrum disorders. Here we show that two-year-olds with autism fail to orient towards point-light displays of biological motion, and their viewing behaviour when watching these point-light displays can be explained instead as a response to non-social, physical contingencies--physical contingencies that are disregarded by control children. This observation has far-reaching implications for understanding the altered neurodevelopmental trajectory of brain specialization in autism.
Two-year-olds with autism orient to nonsocial contingencies rather than biological motion
Klin, Ami; Lin, David J.; Gorrindo, Phillip; Ramsay, Gordon; Jones, Warren
2009-01-01
Typically-developing human infants preferentially attend to biological motion within the first days of life1. This ability is highly conserved across species2,3 and is believed to be critical for filial attachment and for detection of predators4. The neural underpinnings of biological motion perception are overlapping with brain regions involved in perception of basic social signals such as facial expression and gaze direction5, and preferential attention to biological motion is seen as a precursor to the capacity for attributing intentions to others6. However, in a serendipitous observation7, we recently found that an infant with autism failed to recognize point-light displays of biological motion but was instead highly sensitive to the presence of a non-social, physical contingency that occurred within the stimuli by chance. This observation raised the hypothesis that perception of biological motion may be altered in children with autism from a very early age, with cascading consequences for both social development and for the lifelong impairments in social interaction that are a hallmark of autism spectrum disorders8. Here we show that two-year-olds with autism fail to orient towards point-light displays of biological motion, and that their viewing behavior when watching these point-light displays can be explained instead as a response to non-social, physical contingencies physical contingencies that are disregarded by control children. This observation has far-reaching implications for understanding the altered neurodevelopmental trajectory of brain specialization in autism9. PMID:19329996
Meier, Kimberly; Sum, Brian; Giaschi, Deborah
2016-10-01
Global motion sensitivity in typically developing children depends on the spatial (Δx) and temporal (Δt) displacement parameters of the motion stimulus. Specifically, sensitivity for small Δx values matures at a later age, suggesting it may be the most vulnerable to damage by amblyopia. To explore this possibility, we compared motion coherence thresholds of children with amblyopia (7-14years old) to age-matched controls. Three Δx values were used with two Δt values, yielding six conditions covering a range of speeds (0.3-30deg/s). We predicted children with amblyopia would show normal coherence thresholds for the same parameters on which 5-year-olds previously demonstrated mature performance, and elevated coherence thresholds for parameters on which 5-year-olds demonstrated immaturities. Consistent with this, we found that children with amblyopia showed deficits with amblyopic eye viewing compared to controls for small and medium Δx values, regardless of Δt value. The fellow eye showed similar results at the smaller Δt. These results confirm that global motion perception in children with amblyopia is particularly deficient at the finer spatial scales that typically mature later in development. An additional implication is that carefully designed stimuli that are adequately sensitive must be used to assess global motion function in developmental disorders. Stimulus parameters for which performance matures early in life may not reveal global motion perception deficits. Copyright © 2016 Elsevier Ltd. All rights reserved.
An exploration of antecedents of positive affect among the elderly: a cross-sectional study
2016-01-01
Abstract Background: Positive affect contributes to the healthy life style, which, in turn, explains life satisfaction and psychological well-being among the elderly. Existent literature has reinforced that physical activity participation influences development of positive affect for the elderly. Because of the increased life constraints and physical problems, however, maintenance of positive affect might be challenging for elderly people. Methods : Data were drawn from a sample of the Survey of Health, Ageing and Retirement in Europe. A total sample of 3845 males and 3912 females aged between 65 and 103 years from 16 European countries was analyzed. Perception of life constraints, health problems, physical activity engagement and positive affect were measured by a structured questionnaire. Confirmatory factor analysis and a technique of structural equation modelling were employed using Amos 18 to examine the hypothesized relationships between study variables. Results: Perceived life constraints and physical problems significantly affected the acquisition of positive affect among the elderly. Physical activity was found to have a significant path coefficient towards the measure of positive attitude and emotion. Physical activity was also a significant mediator between physical problems and positive affect. Conclusions: This study extended our understanding of how the perception of life constraints and health problems influence the elderly’s daily experience. Study finding reinforced the goodness of physical activity participation to enhance positive affect among the elderly. We should administer sustainable and evidence-based physical activity including interventions and infrastructure to improve positive affect and psychological well-bing among the elderly. PMID:25829500
An exploration of antecedents of positive affect among the elderly: a cross-sectional study.
Lee, Sunwoo
2016-02-01
Positive affect contributes to the healthy life style, which, in turn, explains life satisfaction and psychological well-being among the elderly. Existent literature has reinforced that physical activity participation influences development of positive affect for the elderly. Because of the increased life constraints and physical problems, however, maintenance of positive affect might be challenging for elderly people. Data were drawn from a sample of the Survey of Health, Ageing and Retirement in Europe. A total sample of 3845 males and 3912 females aged between 65 and 103 years from 16 European countries was analyzed. Perception of life constraints, health problems, physical activity engagement and positive affect were measured by a structured questionnaire. Confirmatory factor analysis and a technique of structural equation modelling were employed using Amos 18 to examine the hypothesized relationships between study variables. Perceived life constraints and physical problems significantly affected the acquisition of positive affect among the elderly. Physical activity was found to have a significant path coefficient towards the measure of positive attitude and emotion. Physical activity was also a significant mediator between physical problems and positive affect. This study extended our understanding of how the perception of life constraints and health problems influence the elderly's daily experience. Study finding reinforced the goodness of physical activity participation to enhance positive affect among the elderly. We should administer sustainable and evidence-based physical activity including interventions and infrastructure to improve positive affect and psychological well-bing among the elderly. © The Author 2015. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.
Attachment Style Is Related to Quality of Life for Assistance Dog Owners.
White, Naomi; Mills, Daniel; Hall, Sophie
2017-06-19
Attachment styles have been shown to affect quality of life. Growing interest in the value of companion animals highlights that owning a dog can also affect quality of life, yet little research has explored the role of the attachment bond in affecting the relationship between dog ownership and quality of life. Given that the impact of dog ownership on quality of life may be greater for assistance dog owners than pet dog owners, we explored how anxious attachment and avoidance attachment styles to an assistance dog affected owner quality of life ( n = 73). Regression analysis revealed that higher anxious attachment to the dog predicted enhanced quality of life. It is suggested that the unique, interdependent relationship between an individual and their assistance dog may mean that an anxious attachment style is not necessarily detrimental. Feelings that indicate attachment insecurity in other relationships may reflect more positive aspects of the assistance dog owner relationship, such as the level of support that the dog provides its owner.
Casla, Soraya; López-Tarruella, Sara; Jerez, Yolanda; Marquez-Rodas, Iván; Galvão, Daniel A; Newton, Robert U; Cubedo, Ricardo; Calvo, Isabel; Sampedro, Javier; Barakat, Rubén; Martín, Miguel
2015-09-01
Breast cancer patients suffer impairment in cardiorespiratory fitness after treatment for primary disease, affecting patients' health and survival. The aim of this study was to evaluate the ability of a pragmatic exercise intervention to improve cardiorespiratory fitness of breast cancer patients after primary treatment. Between February 2013 and December 2014, 94 women with early stage (I-III) breast cancer, 1-36 months post-chemotherapy, and radiotherapy were randomly assigned to an intervention program (EX) combining supervised aerobic and resistance exercise (n = 44) or usual care (CON) (n = 45) for 12 weeks. Primary study endpoint was VO2max. Secondary endpoints were muscle strength, shoulder range of motion, body composition, and quality of life (QoL). Assessments were undertaken at baseline, 12-week, and 6-month follow-ups. Eighty-nine patients aged 29-69 years were assessed at baseline and 12 weeks. The EX group showed significant improvements in VO2max, muscle strength, percent fat, and lean mass (p ≤ 0.001 in all cases) and QoL compared with usual care (CON). Apart from body composition, improvements were maintained for the EX at 6-month follow-up. There were no adverse events during the testing or exercise intervention program. A combined exercise intervention produced considerable improvement in cardiorespiratory fitness, physical function, and quality of life in breast cancer patients previously treated with chemotherapy and radiation therapy. Importantly, most of these benefits were maintained 6 months after ceasing the supervised exercise intervention.
Osmotic characteristics and fertility of murine spermatozoa collected in different solutions.
Si, Wei; Men, Hongsheng; Benson, James D; Critser, John K
2009-02-01
Osmotic stress is an important factor that can result in cell damage during cryopreservation. Before ejaculation or collection for cryopreservation, murine spermatozoa are stored in epididymal fluid, a physiologically hyperosmotic environment (approximately 415 mmol/kg). The objectives of this study were to determine the osmotic tolerance limits of sperm motion parameters of ICR and C57BL/6 mouse spermatozoa collected in isosmotic (290 mmol/kg) and hyperosmotic (415 mmol/kg) media, and the effect of the osmolality of sperm collection media on sperm fertility after cryopreservation. Our results indicate that murine spermatozoa collected in media with different osmolalities (290 and 415 mmol/kg Dulbecco's phosphate buffered saline (DPBS)) appeared to have different osmotic tolerances for the maintenance of sperm motility and other motion parameters in both mouse strains. The hypo- and hyperosmotic treatments decreased motility and affected other motion parameters of spermatozoa collected in 290 mmol/kg DPBS. The extent of the change of motion parameters after treatments corresponded with the levels of osmotic stress. However, for spermatozoa collected in 415 mmol/kg DPBS, exposure to 290 mmol/kg DPBS tended to increase sperm motility and the quality of their motion parameters. The osmolality of sperm collection medium can affect murine sperm fertility. Spermatozoa collected in 415 mmol/kg medium showed higher fertility compared with spermatozoa collected in 290 mmol/kg as assessed by IVF. Results characterizing murine sperm osmotic tolerance collected in media with different osmolalities from different strains and the effect of collection media osmolality on sperm fertility after cryopreservation will be useful in designing cryopreservation protocols.
NASA Astrophysics Data System (ADS)
Dhindsa, Gurpreet K.
Neutron scattering has been proved to be a powerful tool to study the dynamics of biological systems under various conditions. This thesis intends to utilize neutron scattering techniques, combining with MD simulations, to develop fundamental understanding of several biologically interesting systems. Our systems include a drug delivery system containing Nanodiamonds with nucleic acid (RNA), and two specific model proteins, beta-Casein and Inorganic Pyrophosphatase (IPPase). RNA and nanodiamond (ND) both are suitable for drug-delivery applications in nano-biotechnology. The architecturally flexible RNA with catalytic functionality forms nanocomposites that can treat life-threatening diseases. The non-toxic ND has excellent mechanical and optical properties and functionalizable high surface area, and thus actively considered for biomedical applications. In this thesis, we utilized two tools, quasielastic neutron scattering (QENS) and Molecular Dynamics Simulations to probe the effect of ND on RNA dynamics. Our work provides fundamental understanding of how hydrated RNA motions are affected in the RNA-ND nanocomposites. From the experimental and Molecular Dynamics Simulation (MD), we found that hydrated RNA motion is faster on ND surface than a freestanding one. MD Simulation results showed that the failure of Stokes Einstein relation results the presence of dynamic heterogeneities in the biomacromolecules. Radial pair distribution function from MD Simulation confirmed that the hydrophilic nature of ND attracts more water than RNA results the de-confinement of RNA on ND. Therefore, RNA exhibits faster motion in the presence of ND than freestanding RNA. In the second project, we studied the dynamics of a natively disordered protein beta-Casein which lacks secondary structures. In this study, the temperature and hydration effects on the dynamics of beta-Casein are explored by Quasielastic Neutron Scattering (QENS). We investigated the mean square displacement (MSD) of hydrated and dry beta-Casein as a function of temperature, to study the effect of hydration on their flexibility. The Elastic Incoherent Structure Factor (EISF) in the energy domain reveals the fraction of hydrogen atoms participating in motion in a sphere of diffusion. In the time domain analysis, a logarithmic-like decay is observed in the range of picosecond to nanosecond (beta-relaxation time) in the dynamics of hydrated beta-Casein. Our temperature dependent QENS experiments provide evidence that lack of secondary structure in beta-Casein results in higher flexibility in its dynamics and easier reversible thermal unfolding compared to other rigid biomolecules. Lastly, we studied the domain motion of IPPase protein by Neutron Spin Echo Spectroscopy (NSE). We found that decrease in diffusion coefficient belongs to domain motion of IPPase. Moreover, Rg is varied by temperature and concentration.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-15
... to Regulations Regarding Major Life-Changing Events Affecting Income-Related Monthly Adjustment... major life-changing events for the Medicare Part B income- related monthly adjustment amount (IRMAA) and what evidence we require to support a claim of a major life-changing event. Recent changes in the...
Reader, Arran T; Holmes, Nicholas P
2015-01-01
Imitation is an important form of social behavior, and research has aimed to discover and explain the neural and kinematic aspects of imitation. However, much of this research has featured single participants imitating in response to pre-recorded video stimuli. This is in spite of findings that show reduced neural activation to video vs. real life movement stimuli, particularly in the motor cortex. We investigated the degree to which video stimuli may affect the imitation process using a novel motion tracking paradigm with high spatial and temporal resolution. We recorded 14 positions on the hands, arms, and heads of two individuals in an imitation experiment. One individual freely moved within given parameters (moving balls across a series of pegs) and a second participant imitated. This task was performed with either simple (one ball) or complex (three balls) movement difficulty, and either face-to-face or via a live video projection. After an exploratory analysis, three dependent variables were chosen for examination: 3D grip position, joint angles in the arm, and grip aperture. A cross-correlation and multivariate analysis revealed that object-directed imitation task accuracy (as represented by grip position) was reduced in video compared to face-to-face feedback, and in complex compared to simple difficulty. This was most prevalent in the left-right and forward-back motions, relevant to the imitator sitting face-to-face with the actor or with a live projected video of the same actor. The results suggest that for tasks which require object-directed imitation, video stimuli may not be an ecologically valid way to present task materials. However, no similar effects were found in the joint angle and grip aperture variables, suggesting that there are limits to the influence of video stimuli on imitation. The implications of these results are discussed with regards to previous findings, and with suggestions for future experimentation.
Johanson, Suzanne; Bejerholm, Ulrika
2017-09-01
Sick leave and unemployment are highly prevalent among people with affective disorders. Their depression severity is disabling and inversely related to having employment. No evidence-based vocational rehabilitation exists for this target group. Knowledge is therefore needed to understand the psychosocial factors that affect depression severity in order to develop new rehabilitation interventions. This study examined relationships between depression severity and empowerment, working life aspirations, occupational engagement, and quality of life in unemployed people with affective disorders receiving mental healthcare. In this cross-sectional study of 61 participants, instruments on psychosocial factors and questions on descriptive sociodemographic and clinical characteristics were administered. Descriptive, correlation, and regression statistics were applied. Correlation and regression analyses showed significant inverse relations between depression severity and empowerment and quality of life. The odds for more severe depression decreased with higher empowerment and quality of life. However, neither extent of engagement in daily life nor working life aspiration was related to depression severity. An empowerment approach and strategies, which support the quality of life, are needed in development of vocational rehabilitation interventions, and bridging of mental healthcare and vocational services. Implications for Rehabilitation Enhancing empowerment and quality life in the return to work process can decrease depression severity in unemployed people with affective disorder. There is a need to address work issues in addition to symptom reduction in primary and mental healthcare. Bridging the service and time gap between vocational rehabilitation and healthcare is recommended for mitigating long-term unemployment for people with affective disorders who want to work.
The movement ecology and dynamics of plant communities in fragmented landscapes.
Damschen, Ellen I; Brudvig, Lars A; Haddad, Nick M; Levey, Douglas J; Orrock, John L; Tewksbury, Joshua J
2008-12-09
A conceptual model of movement ecology has recently been advanced to explain all movement by considering the interaction of four elements: internal state, motion capacity, navigation capacities, and external factors. We modified this framework to generate predictions for species richness dynamics of fragmented plant communities and tested them in experimental landscapes across a 7-year time series. We found that two external factors, dispersal vectors and habitat features, affected species colonization and recolonization in habitat fragments and their effects varied and depended on motion capacity. Bird-dispersed species richness showed connectivity effects that reached an asymptote over time, but no edge effects, whereas wind-dispersed species richness showed steadily accumulating edge and connectivity effects, with no indication of an asymptote. Unassisted species also showed increasing differences caused by connectivity over time, whereas edges had no effect. Our limited use of proxies for movement ecology (e.g., dispersal mode as a proxy for motion capacity) resulted in moderate predictive power for communities and, in some cases, highlighted the importance of a more complete understanding of movement ecology for predicting how landscape conservation actions affect plant community dynamics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damschen, Ellen I.; Brudvig, Lars A.; Haddad, Nick M.
A conceptual model of movement ecology has recently been advanced to explain all movement by considering the interaction of four elements: internal state, motion capacity, navigation capacities,and external factors. We modified this framework togenerate predictions for species richness dynamics of fragmented plant communities and tested them in experimental landscapes across a 7-year time series. We found that two external factors, dispersal vectors and habitat features, affected species colonization and recolonization in habitat fragments and their effects varied and depended on motion capacity. Bird-dispersed species richness showed connectivity effects that reached an asymptote over time, but no edge effects, whereas wind-dispersedmore » species richness showed steadily accumulating edge and connectivity effects, with no indication of an asymptote. Unassisted species also showed increasing differences caused by connectivity over time,whereas edges had no effect. Our limited use of proxies for movement ecology (e.g., dispersal mode as a proxy for motion capacity) resulted in moderate predictive power for communities and, in some cases, highlighted the importance of a more complete understanding of movement ecology for predicting how landscape conservation actions affect plant community dynamics.« less
Single molecule detection, thermal fluctuation and life
YANAGIDA, Toshio; ISHII, Yoshiharu
2017-01-01
Single molecule detection has contributed to our understanding of the unique mechanisms of life. Unlike artificial man-made machines, biological molecular machines integrate thermal noises rather than avoid them. For example, single molecule detection has demonstrated that myosin motors undergo biased Brownian motion for stepwise movement and that single protein molecules spontaneously change their conformation, for switching to interactions with other proteins, in response to thermal fluctuation. Thus, molecular machines have flexibility and efficiency not seen in artificial machines. PMID:28190869
ERIC Educational Resources Information Center
Olson, Catherine Applefeld
2008-01-01
Travel of any sort--to performances, competitions, or other events--can be a bonding, life-broadening experience for students and teachers alike. For students, travel offers unparalleled learning opportunities. However, for teachers, travel can sometimes be a logistical nightmare. Gearing up for trips requires plenty of advance planning, precise…
Rep. Woolsey, Lynn C. [D-CA-6
2010-03-16
House - 06/15/2010 On motion to suspend the rules and pass the bill, as amended Failed by the Yeas and Nays: (2/3 required): 249 - 163 (Roll no. 360). (All Actions) Tracker: This bill has the status Failed HouseHere are the steps for Status of Legislation:
Emergence of Life-Like Properties from Dissipative Self-Assembly of Nanoparticles
NASA Astrophysics Data System (ADS)
Ilday, Serim; Makey, Ghaith; Akguc, Gursoy B.; Yavuz, Ozgun; Tokel, Onur; Pavlov, Ihor; Gulseren, Oguz; Ilday, F. Omer
A profoundly fundamental question at the interface between physics and biology remains open: What are the minimum requirements for emergence of life-like properties from non-living systems? Here, we address this question and report emergent complex behavior of tens to thousands of colloidal nanoparticles in a system designed to be as plain as possible: The system is driven far from equilibrium by ultrafast laser pulses, which create spatiotemporal temperature gradients, inducing Marangoni-type flow that drags the particles towards aggregation; strong Brownian motion, used as source of fluctuations, opposes aggregation. Nonlinear feedback mechanisms naturally arise between the flow, the aggregate, and Brownian motion, allowing fast external control with minimal intervention. Consequently, complex behavior, analogous to those commonly seen in living organisms, emerges, whereby the aggregates can self-sustain, self-regulate, self-replicate, self-heal and can be transferred from one location to another, all within seconds. Aggregates can comprise of only one pattern or bifurcated patterns can co-exist, compete, survive or die.
An unsupervised method for summarizing egocentric sport videos
NASA Astrophysics Data System (ADS)
Habibi Aghdam, Hamed; Jahani Heravi, Elnaz; Puig, Domenec
2015-12-01
People are getting more interested to record their sport activities using head-worn or hand-held cameras. This type of videos which is called egocentric sport videos has different motion and appearance patterns compared with life-logging videos. While a life-logging video can be defined in terms of well-defined human-object interactions, notwithstanding, it is not trivial to describe egocentric sport videos using well-defined activities. For this reason, summarizing egocentric sport videos based on human-object interaction might fail to produce meaningful results. In this paper, we propose an unsupervised method for summarizing egocentric videos by identifying the key-frames of the video. Our method utilizes both appearance and motion information and it automatically finds the number of the key-frames. Our blind user study on the new dataset collected from YouTube shows that in 93:5% cases, the users choose the proposed method as their first video summary choice. In addition, our method is within the top 2 choices of the users in 99% of studies.
Microstructures and fatigue life of SnAgCu solder joints bearing Nano-Al particles in QFP devices
NASA Astrophysics Data System (ADS)
Zhang, Liang; Fan, Xi-ying; Guo, Yong-huan; He, Cheng-wen
2014-05-01
Microstructures and fatigue life of SnAgCu and SnAgCu bearing nano-Al particles in QFP (Quad flat package) devices were investigated, respectively. Results show that the addition of nano-Al particles into SnAgCu solder can refine the microstructures of matrix microstructure. Moreover, the nano-Al particles present in the solder matrix, act as obstacles which can create a back stress, resisting the motion of dislocations. In QFP device, it is found that the addition of nano-Al particles can increase the fatigue life by 32% compared with the SnAgCu solder joints during thermal cycling loading.
Numeric calculation of celestial bodies with spreadsheet analysis
NASA Astrophysics Data System (ADS)
Koch, Alexander
2016-04-01
The motion of the planets and moons in our solar system can easily be calculated for any time by the Kepler laws of planetary motion. The Kepler laws are a special case of the gravitational law of Newton, especially if you consider more than two celestial bodies. Therefore it is more basic to calculate the motion by using the gravitational law. But the problem is, that by gravitational law it is not possible to calculate the state of motion with only one step of calculation. The motion has to be numerical calculated for many time intervalls. For this reason, spreadsheet analysis is helpful for students. Skills in programmes like Excel, Calc or Gnumeric are important in professional life and can easily be learnt by students. These programmes can help to calculate the complex motions with many intervalls. The more intervalls are used, the more exact are the calculated orbits. The sutdents will first get a quick course in Excel. After that they calculate with instructions the 2-D-coordinates of the orbits of Moon and Mars. Step by step the students are coding the formulae for calculating physical parameters like coordinates, force, acceleration and velocity. The project is limited to 4 weeks or 8 lessons. So the calcualtion will only include the calculation of one body around the central mass like Earth or Sun. The three-body problem can only be shortly discussed at the end of the project.
Evaluation of seismic performance of reinforced concrete (RC) buildings under near-field earthquakes
NASA Astrophysics Data System (ADS)
Moniri, Hassan
2017-03-01
Near-field ground motions are significantly severely affected on seismic response of structure compared with far-field ground motions, and the reason is that the near-source forward directivity ground motions contain pulse-long periods. Therefore, the cumulative effects of far-fault records are minor. The damage and collapse of engineering structures observed in the last decades' earthquakes show the potential of damage in existing structures under near-field ground motions. One important subject studied by earthquake engineers as part of a performance-based approach is the determination of demand and collapse capacity under near-field earthquake. Different methods for evaluating seismic structural performance have been suggested along with and as part of the development of performance-based earthquake engineering. This study investigated the results of illustrious characteristics of near-fault ground motions on the seismic response of reinforced concrete (RC) structures, by the use of Incremental Nonlinear Dynamic Analysis (IDA) method. Due to the fact that various ground motions result in different intensity-versus-response plots, this analysis is done again under various ground motions in order to achieve significant statistical averages. The OpenSees software was used to conduct nonlinear structural evaluations. Numerical modelling showed that near-source outcomes cause most of the seismic energy from the rupture to arrive in a single coherent long-period pulse of motion and permanent ground displacements. Finally, a vulnerability of RC building can be evaluated against pulse-like near-fault ground motions effects.
Modeling a space-variant cortical representation for apparent motion.
Wurbs, Jeremy; Mingolla, Ennio; Yazdanbakhsh, Arash
2013-08-06
Receptive field sizes of neurons in early primate visual areas increase with eccentricity, as does temporal processing speed. The fovea is evidently specialized for slow, fine movements while the periphery is suited for fast, coarse movements. In either the fovea or periphery discrete flashes can produce motion percepts. Grossberg and Rudd (1989) used traveling Gaussian activity profiles to model long-range apparent motion percepts. We propose a neural model constrained by physiological data to explain how signals from retinal ganglion cells to V1 affect the perception of motion as a function of eccentricity. Our model incorporates cortical magnification, receptive field overlap and scatter, and spatial and temporal response characteristics of retinal ganglion cells for cortical processing of motion. Consistent with the finding of Baker and Braddick (1985), in our model the maximum flash distance that is perceived as an apparent motion (Dmax) increases linearly as a function of eccentricity. Baker and Braddick (1985) made qualitative predictions about the functional significance of both stimulus and visual system parameters that constrain motion perception, such as an increase in the range of detectable motions as a function of eccentricity and the likely role of higher visual processes in determining Dmax. We generate corresponding quantitative predictions for those functional dependencies for individual aspects of motion processing. Simulation results indicate that the early visual pathway can explain the qualitative linear increase of Dmax data without reliance on extrastriate areas, but that those higher visual areas may serve as a modulatory influence on the exact Dmax increase.
Cinnarizine for Sea Sickness During a Remote Pacific Ocean Rescue Mission.
Lyon, Regan F; Rush, Stephen C; Roland, J Thomas; Jethanamest, Daniel; Schwan, Christopher P; Kharon, Chetan U
2015-01-01
Motion sickness can be a limiting factor for sea and air missions. We report the experience of a Pararescue (PJ) team on a Pacific Ocean rescue mission in which motion sickness was prevalent. Cinnarizine, an antagonist of H1-histamine receptors, was used to treat affected PJs. We also report findings of a survey of PJs regarding motion sickness. A family of four on a disabled sailboat 900 miles off the coast of Mexico sent out a distress call because their 1-year-old daughter became severely ill with fever and diarrhea. Four PJs were deployed on a C-130, performed a free-fall parachute insertion into the ocean, and boarded the sailboat. All four PJs experienced onset of motion sickness at some point during the early part of the mission and symptoms persisted through the first 24 hours. Three PJs experienced ongoing nausea, vomiting, dizziness, and sensory imbalances. The captain of the sailboat offered the three sick PJs approximately 18mg of cinnarizine two or three times a day with relief of symptoms and improvement on operational effectiveness. A new, anonymous, voluntary survey of Air National Guard PJs and combat rescue officers revealed that 78.4% of Operators have experienced motion sickness at sea. We discuss the current theories on motion sickness, the effect of motion sickness on operational effectiveness, and research on treatment of motion sickness, including the medication cinnarizine. 2015.
Design and characterisation of a wall motion phantom.
Dineley, J; Meagher, S; Poepping, T L; McDicken, W N; Hoskins, P R
2006-09-01
Arterial wall motion is an essential feature of a healthy cardiovascular system and it is known that wall motion is affected by age and disease. In recent years, methods have been developed for measurement of wall motion with the intention of providing diagnostically useful information. An issue with all of these techniques is the accuracy and variability of both wall motion and derived quantities such as elasticity, which requires the development of suitable test tools. In this paper, a vessel wall phantom is described for use in ultrasound studies of wall motion. The vessel was made from polyvinyl alcohol (PVA) subjected to a freeze-thaw process to form a cryogel (PVA-C). The elastic modulus, acoustic velocity and attenuation coefficient varied from 57 kPa, 1543 m s(-1) and 0.18 dB cm(-1) MHz(-1) for one freeze-thaw cycle to 330 kPa, 1583 m s(-1) and 0.42 dB cm(-1) MHz(-1) for 10 freeze-thaw cycles. Wall motion was effected by the use of pulsatile flow produced from a gear pump. The use of a downstream flow resistor removed gross distortions in the wall motion waveform, possibly by removal of reflected pressure waves. However, a low amplitude 20 Hz oscillation remained, which is unphysiologic and thought to be caused by the vibration of the distended PVA-C vessel.
Motion of Air Bubbles in Water Subjected to Microgravity Accelerations
NASA Technical Reports Server (NTRS)
DeLombard, Richard; Kelly, Eric M.; Hrovat, Kenneth; Nelson, Emily S.; Pettit, Donald R.
2006-01-01
The International Space Station (ISS) serves as a platform for microgravity research for the foreseeable future. A microgravity environment is one in which the effects of gravity are drastically reduced which then allows physical experiments to be conducted without the over powering effects of gravity. During his 6-month stay on the ISS, astronaut Donald R. Pettit performed many informal/impromptu science experiments with available equipment. One such experiment focused on the motion of air bubbles in a rectangular container nearly filled with de-ionized water. Bubbles were introduced by shaking and then the container was secured in place for several hours while motion of the bubbles was recorded using time-lapse photography. This paper shows correlation between bubble motion and quasi-steady acceleration levels during one such experiment operation. The quasi-steady acceleration vectors were measured by the Microgravity Acceleration Measurement System (MAMS). Essentially linear motion was observed in the condition considered here. Dr. Pettit also created other conditions which produced linear and circulating motion, which are the subjects of further study. Initial observations of this bubble motion agree with calculations from many microgravity physical science experiments conducted on shuttle microgravity science missions. Many crystal-growth furnaces involve heavy metals and high temperatures in which undesired acceleration-driven convection during solidification can adversely affect the crystal. Presented in this paper will be results showing correlation between bubble motion and the quasi-steady acceleration vector.
Indovina, Iole; Maffei, Vincenzo; Lacquaniti, Francesco
2013-09-01
By simulating self-motion on a virtual rollercoaster, we investigated whether acceleration cued by the optic flow affected the estimate of time-to-passage (TTP) to a target. In particular, we studied the role of a visual acceleration (1 g = 9.8 m/s(2)) simulating the effects of gravity in the scene, by manipulating motion law (accelerated or decelerated at 1 g, constant speed) and motion orientation (vertical, horizontal). Thus, 1-g-accelerated motion in the downward direction or decelerated motion in the upward direction was congruent with the effects of visual gravity. We found that acceleration (positive or negative) is taken into account but is overestimated in module in the calculation of TTP, independently of orientation. In addition, participants signaled TTP earlier when the rollercoaster accelerated downward at 1 g (as during free fall), with respect to when the same acceleration occurred along the horizontal orientation. This time shift indicates an influence of the orientation relative to visual gravity on response timing that could be attributed to the anticipation of the effects of visual gravity on self-motion along the vertical, but not the horizontal orientation. Finally, precision in TTP estimates was higher during vertical fall than when traveling at constant speed along the vertical orientation, consistent with a higher noise in TTP estimates when the motion violates gravity constraints.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ali, I; Algan, O; Ahmad, S
Purpose: To model patient motion and produce four-dimensional (4D) optimized dose distributions that consider motion-artifacts in the dose calculation during the treatment planning process. Methods: An algorithm for dose calculation is developed where patient motion is considered in dose calculation at the stage of the treatment planning. First, optimal dose distributions are calculated for the stationary target volume where the dose distributions are optimized considering intensity-modulated radiation therapy (IMRT). Second, a convolution-kernel is produced from the best-fitting curve which matches the motion trajectory of the patient. Third, the motion kernel is deconvolved with the initial dose distribution optimized for themore » stationary target to produce a dose distribution that is optimized in four-dimensions. This algorithm is tested with measured doses using a mobile phantom that moves with controlled motion patterns. Results: A motion-optimized dose distribution is obtained from the initial dose distribution of the stationary target by deconvolution with the motion-kernel of the mobile target. This motion-optimized dose distribution is equivalent to that optimized for the stationary target using IMRT. The motion-optimized and measured dose distributions are tested with the gamma index with a passing rate of >95% considering 3% dose-difference and 3mm distance-to-agreement. If the dose delivery per beam takes place over several respiratory cycles, then the spread-out of the dose distributions is only dependent on the motion amplitude and not affected by motion frequency and phase. This algorithm is limited to motion amplitudes that are smaller than the length of the target along the direction of motion. Conclusion: An algorithm is developed to optimize dose in 4D. Besides IMRT that provides optimal dose coverage for a stationary target, it extends dose optimization to 4D considering target motion. This algorithm provides alternative to motion management techniques such as beam-gating or breath-holding and has potential applications in adaptive radiation therapy.« less
SME Worker Affective (SWA) index based on environmental ergonomics
NASA Astrophysics Data System (ADS)
Ushada, M.; Kusuma Aji, G.; Okayama, T.; Khidir, M.
2018-04-01
Small-Medium sized (SME) is a focal type of Indonesian industry which contributes to national emerging economies. Indonesian goverment has developed employee social security system (BPJS Ketenagakerjaan) to support worker quality of life. However, there were limited research which could assist BPJS Ketenagakerjaan in evaluating worker quality of life. Worker quality of life could be categorized as the highest worker needs or affective states. SME Worker Affective (SWA) index is being concerned as a basic tool to make balance between worker performance and quality of life in workstation of SMEs. The research objectives are: 1) To optimize the environmental ergonomics in SMEs; 2) To quantify SME Worker Affective (SWA) index based on optimized environmental ergonomics. The research advantage is to support Indonesian goverment in monitoring SMEs good practices to its worker quality of life. Simulated annealing optimized the heart rate and environmental ergonomics parameters. SWA index was determined based on comparison between optimized heart rate and environmental ergonomics parameters. SWA index were quantified for 380 data of worker. The evaluation indicated 51.3% worker in affective and 48.7% in non-affective condition. Research results indicated that stakeholders of SMEs should put more attention on environmental ergonomics and worker affective.
Tidal Effects on the Oort Cloud Comets and Dynamics of the Sun in the Spiral Arms of the Galaxy
NASA Astrophysics Data System (ADS)
De Biasi, Alice
2014-01-01
The Solar System presents a complex dynamical structure and is not isolated from the Galaxy. In particular the comet reservoir of our planetary system, the Oort cloud, is extremely sensitive to the the galactic environment due to its peripheral collocation inside the Solar System. In this framework, the growing evidences about a possible migration of the Sun open new research scenarios relative to the effects that such kind of migration might induce on the cometary motion. Following several previous studied, we identified the spiral arm structure as the main perturbation that is able to produce an efficient solar migration through the disk. Widening the classical model for the spiral arms, provided by Lin& Shu to a 3D formalism, we verified the compatibility between the presence of the spiral perturbation and a significant solar motion for an inner Galactic position to the current one, in agreement with the constrains in position, velocity and metallicity due to the present conditions of our star. The main perturbers of the Oort cloud, the close stellar passages and the tidal field of the Galaxy, might be both affected by the variation of Galactic environment that the solar migration entails. Despite that, in order to isolate the effects to the two different perturbators, we decided to focus our attention only on the Galactic tide. The perturbation due to the spiral structure was included in the study on the cometary motion, introducing the solar migration and adding the direct presence of the non-axisymmetric component in the Galactic potential of the tidal field. The results show a significant influence of the spiral arm in particular on cometary objects belonged to the outer shell of the Oort cloud, for which provides an injection rate three times bigger than the integration performed without the spiral arms. The introduction of the spiral perturbation seems to bolster the planar component of the tide, indeed it produces the most significant variation of the perihelion distance for moderate inclination orbits with respect to the plane. The peak for the cometary injections has been registered between 6 and 7 kpc. If this evidence will be confirmed by more realistic cometary sample, it might involve a redefinition of the habitability edges in the Galaxy (GHZ). In particular regions not precluded to the formation of life, may compromise the development of the life with a high cometary impact risk
Wilms, M; Werner, R; Blendowski, M; Ortmüller, J; Handels, H
2014-01-01
A major problem associated with the irradiation of thoracic and abdominal tumors is respiratory motion. In clinical practice, motion compensation approaches are frequently steered by low-dimensional breathing signals (e.g., spirometry) and patient-specific correspondence models, which are used to estimate the sought internal motion given a signal measurement. Recently, the use of multidimensional signals derived from range images of the moving skin surface has been proposed to better account for complex motion patterns. In this work, a simulation study is carried out to investigate the motion estimation accuracy of such multidimensional signals and the influence of noise, the signal dimensionality, and different sampling patterns (points, lines, regions). A diffeomorphic correspondence modeling framework is employed to relate multidimensional breathing signals derived from simulated range images to internal motion patterns represented by diffeomorphic non-linear transformations. Furthermore, an automatic approach for the selection of optimal signal combinations/patterns within this framework is presented. This simulation study focuses on lung motion estimation and is based on 28 4D CT data sets. The results show that the use of multidimensional signals instead of one-dimensional signals significantly improves the motion estimation accuracy, which is, however, highly affected by noise. Only small differences exist between different multidimensional sampling patterns (lines and regions). Automatically determined optimal combinations of points and lines do not lead to accuracy improvements compared to results obtained by using all points or lines. Our results show the potential of multidimensional breathing signals derived from range images for the model-based estimation of respiratory motion in radiation therapy.
Heavy enzymes--experimental and computational insights in enzyme dynamics.
Swiderek, Katarzyna; Ruiz-Pernía, J Javier; Moliner, Vicent; Tuñón, Iñaki
2014-08-01
The role of protein motions in the chemical step of enzyme-catalyzed reactions is the subject of an open debate in the scientific literature. The systematic use of isotopically substituted enzymes has been revealed as a useful tool to quantify the role of these motions. According to the Born-Oppenheimer approximation, changing the mass of the protein does not change the forces acting on the system but alters the frequencies of the protein motions, which in turn can affect the rate constant. Experimental and theoretical studies carried out in this field are presented in this article and discussed in the framework of Transition State Theory. Copyright © 2014 Elsevier Ltd. All rights reserved.
Puerto Rico Strong Motion Seismic Network
NASA Astrophysics Data System (ADS)
Huerta-Lopez, C. I.; Martínez-Cruzado, J. A.; Martínez-Pagan, J.; Santana-Torres, E. X.; Torres-O, D. M.
2014-12-01
The Puerto Rico Strong Motion Seismic Network is currently in charge of the operation of: (i) free-field (ff) strong motion stations, (ii) instrumented structures (STR) (Dams, Bridges, Buildings), and (iii) the data acquisition/monitoring and analysis of earthquakes considered strong from the point of view of their intensity and magnitude. All these instruments are deployed in the Puerto Rico Island (PRI), US-, and British-Virgin Islands (BVI), and Dominican Republic (DR). The Puerto Rico Island and the Caribbean region have high potential to be affected by earthquakes that could be catastrophic for the area. The Puerto Rico Strong Motion Seismic Network (actually Puerto Rico Strong Motion Program, PRSMP) has grown since 1970's from 7 ff strong motion stations and one instrumented building with analog accelerographs to 111 ff strong motion stations and 16 instrumented buildings with digital accelerographs: PRI: 88 ff, 16 STR., DR: 13 ff, BVI: 5 ff, 2 STR collecting data via IP (internet), DU (telephone), and stand alone stations The current stage of the PRSMP seismic network, the analysis of moderate earthquakes that were recorded and/or occurred on the island, results of the intensity distribution of selected earthquakes, as well as results of dynamic parameter identification of some of the instrumented structures are here presented.
Plenoptic Image Motion Deblurring.
Chandramouli, Paramanand; Jin, Meiguang; Perrone, Daniele; Favaro, Paolo
2018-04-01
We propose a method to remove motion blur in a single light field captured with a moving plenoptic camera. Since motion is unknown, we resort to a blind deconvolution formulation, where one aims to identify both the blur point spread function and the latent sharp image. Even in the absence of motion, light field images captured by a plenoptic camera are affected by a non-trivial combination of both aliasing and defocus, which depends on the 3D geometry of the scene. Therefore, motion deblurring algorithms designed for standard cameras are not directly applicable. Moreover, many state of the art blind deconvolution algorithms are based on iterative schemes, where blurry images are synthesized through the imaging model. However, current imaging models for plenoptic images are impractical due to their high dimensionality. We observe that plenoptic cameras introduce periodic patterns that can be exploited to obtain highly parallelizable numerical schemes to synthesize images. These schemes allow extremely efficient GPU implementations that enable the use of iterative methods. We can then cast blind deconvolution of a blurry light field image as a regularized energy minimization to recover a sharp high-resolution scene texture and the camera motion. Furthermore, the proposed formulation can handle non-uniform motion blur due to camera shake as demonstrated on both synthetic and real light field data.
Effects of attention and laterality on motion and orientation discrimination in deaf signers.
Bosworth, Rain G; Petrich, Jennifer A F; Dobkins, Karen R
2013-06-01
Previous studies have asked whether visual sensitivity and attentional processing in deaf signers are enhanced or altered as a result of their different sensory experiences during development, i.e., auditory deprivation and exposure to a visual language. In particular, deaf and hearing signers have been shown to exhibit a right visual field/left hemisphere advantage for motion processing, while hearing nonsigners do not. To examine whether this finding extends to other aspects of visual processing, we compared deaf signers and hearing nonsigners on motion, form, and brightness discrimination tasks. Secondly, to examine whether hemispheric lateralities are affected by attention, we employed a dual-task paradigm to measure form and motion thresholds under "full" vs. "poor" attention conditions. Deaf signers, but not hearing nonsigners, exhibited a right visual field advantage for motion processing. This effect was also seen for form processing and not for the brightness task. Moreover, no group differences were observed in attentional effects, and the motion and form visual field asymmetries were not modulated by attention, suggesting they occur at early levels of sensory processing. In sum, the results show that processing of motion and form, believed to be mediated by dorsal and ventral visual pathways, respectively, are left-hemisphere dominant in deaf signers. Published by Elsevier Inc.