Sample records for affermazioni seguenti sono

  1. SONOS Nonvolatile Memory Cell Programming Characteristics

    NASA Technical Reports Server (NTRS)

    MacLeod, Todd C.; Phillips, Thomas A.; Ho, Fat D.

    2010-01-01

    Silicon-oxide-nitride-oxide-silicon (SONOS) nonvolatile memory is gaining favor over conventional EEPROM FLASH memory technology. This paper characterizes the SONOS write operation using a nonquasi-static MOSFET model. This includes floating gate charge and voltage characteristics as well as tunneling current, voltage threshold and drain current characterization. The characterization of the SONOS memory cell predicted by the model closely agrees with experimental data obtained from actual SONOS memory cells. The tunnel current, drain current, threshold voltage and read drain current all closely agreed with empirical data.

  2. Modeling of Sonos Memory Cell Erase Cycle

    NASA Technical Reports Server (NTRS)

    Phillips, Thomas A.; MacLeond, Todd C.; Ho, Fat D.

    2010-01-01

    Silicon-oxide-nitride-oxide-silicon (SONOS) nonvolatile semiconductor memories (NVSMS) have many advantages. These memories are electrically erasable programmable read-only memories (EEPROMs). They utilize low programming voltages, endure extended erase/write cycles, are inherently resistant to radiation, and are compatible with high-density scaled CMOS for low power, portable electronics. The SONOS memory cell erase cycle was investigated using a nonquasi-static (NQS) MOSFET model. The SONOS floating gate charge and voltage, tunneling current, threshold voltage, and drain current were characterized during an erase cycle. Comparisons were made between the model predictions and experimental device data.

  3. SONOS technology for commercial and military nonvolatile memory applications

    NASA Astrophysics Data System (ADS)

    Adams, D.; Farrell, P.; Jacunski, M.; Williams, D.; Jakubczak, J.; Knoll, M.; Murray, J.

    Silicon Oxide Nitride Oxide Semiconductor (SONOS) technology is well suited for military and commercial nonvolatile memory applications. Excellent long term memory retention, radiation hardness, and endurance has been demonstrated with this technology. This paper summarizes our data in these areas for SONOS technology.

  4. Modeling of SONOS Memory Cell Erase Cycle

    NASA Technical Reports Server (NTRS)

    Phillips, Thomas A.; MacLeod, Todd C.; Ho, Fat H.

    2011-01-01

    Utilization of Silicon-Oxide-Nitride-Oxide-Silicon (SONOS) nonvolatile semiconductor memories as a flash memory has many advantages. These electrically erasable programmable read-only memories (EEPROMs) utilize low programming voltages, have a high erase/write cycle lifetime, are radiation hardened, and are compatible with high-density scaled CMOS for low power, portable electronics. In this paper, the SONOS memory cell erase cycle was investigated using a nonquasi-static (NQS) MOSFET model. Comparisons were made between the model predictions and experimental data.

  5. Effect of acoustic parameters on the cavitation behavior of SonoVue microbubbles induced by pulsed ultrasound.

    PubMed

    Lin, Yutong; Lin, Lizhou; Cheng, Mouwen; Jin, Lifang; Du, Lianfang; Han, Tao; Xu, Lin; Yu, Alfred C H; Qin, Peng

    2017-03-01

    SonoVue microbubbles could serve as artificial nuclei for ultrasound-triggered stable and inertial cavitation, resulting in beneficial biological effects for future therapeutic applications. To optimize and control the use of the cavitation of SonoVue bubbles in therapy while ensuring safety, it is important to comprehensively understand the relationship between the acoustic parameters and the cavitation behavior of the SonoVue bubbles. An agarose-gel tissue phantom was fabricated to hold the SonoVue bubble suspension. 1-MHz transmitting transducer calibrated by a hydrophone was used to trigger the cavitation of SonoVue bubbles under different ultrasonic parameters (i.e., peak rarefactional pressure (PRP), pulse repetition frequency (PRF), and pulse duration (PD)). Another 7.5-MHz focused transducer was employed to passively receive acoustic signals from the exposed bubbles. The ultraharmonics and broadband intensities in the acoustic emission spectra were measured to quantify the extent of stable and inertial cavitation of SonoVue bubbles, respectively. We found that the onset of both stable and inertial cavitation exhibited a strong dependence on the PRP and PD and a relatively weak dependence on the PRF. Approximate 0.25MPa PRP with more than 20μs PD was considered to be necessary for ultraharmonics emission of SonoVue bubbles, and obvious broadband signals started to appear when the PRP exceeded 0.40MPa. Moreover, the doses of stable and inertial cavitation varied with the PRP. The stable cavitation dose initially increased with increasing PRP, and then decreased rapidly after 0.5MPa. By contrast, the inertial cavitation dose continuously increased with increasing PRP. Finally, the doses of both stable and inertial cavitation were positively correlated with PRF and PD. These results could provide instructive information for optimizing future therapeutic applications of SonoVue bubbles. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Memristive device based on a depletion-type SONOS field effect transistor

    NASA Astrophysics Data System (ADS)

    Himmel, N.; Ziegler, M.; Mähne, H.; Thiem, S.; Winterfeld, H.; Kohlstedt, H.

    2017-06-01

    State-of-the-art SONOS (silicon-oxide-nitride-oxide-polysilicon) field effect transistors were operated in a memristive switching mode. The circuit design is a variation of the MemFlash concept and the particular properties of depletion type SONOS-transistors were taken into account. The transistor was externally wired with a resistively shunted pn-diode. Experimental current-voltage curves show analog bipolar switching characteristics within a bias voltage range of ±10 V, exhibiting a pronounced asymmetric hysteresis loop. The experimental data are confirmed by SPICE simulations. The underlying memristive mechanism is purely electronic, which eliminates an initial forming step of the as-fabricated cells. This fact, together with reasonable design flexibility, in particular to adjust the maximum R ON/R OFF ratio, makes these cells attractive for neuromorphic applications. The relative large set and reset voltage around ±10 V might be decreased by using thinner gate-oxides. The all-electric operation principle, in combination with an established silicon manufacturing process of SONOS devices at the Semiconductor Foundry X-FAB, promise reliable operation, low parameter spread and high integration density.

  7. Advanced oxidation of Reactive Blue 181 solution: a comparison between Fenton and Sono-Fenton process.

    PubMed

    Basturk, Emine; Karatas, Mustafa

    2014-09-01

    In this work, the decolorization of C.I. Reactive Blue 181 (RB181), an anthraquinone dye, by Ultrasound and Fe(2+) H2O2 processes was investigated. The effects of operating parameters, such as Fe(2+) dosage, H2O2 dosage, pH value, reaction time and temperature were examined. Process optimisation [pH, ferrous ion (Fe(2+)), hydrogen peroxide (H2O2), and reaction time], kinetic studies and their comparison were carried out for both of the processes. The Sono-Fenton process was performed by indirect sonication in an ultrasonic water bath, which was operated at a fixed 35-kHz frequency. The optimum conditions were determined as [Fe(2+)]=30 mg/L, [H2O2]=50 mg/L and pH=3 for the Fenton process and [Fe(2+)]=10 mg/L, [H2O2]=40 mg/L and pH=3 for the Sono-Fenton process. The colour removals were 88% and 93.5% by the Fenton and Sono-Fenton processes, respectively. The highest decolorization was achieved by the Sono-Fenton process because of the production of some oxidising agents as a result of sonication. The paper also discussed kinetic parameters. The decolorization kinetic of RB181 followed pseudo-second-order reaction (Fenton study) and Behnajady kinetics (Sono-Fenton study). Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Sono-photocatalytic production of hydrogen by interface modified metal oxide insulators.

    PubMed

    Senevirathne, Rushdi D; Abeykoon, Lahiru K; De Silva, Nuwan L; Yan, Chang-Feng; Bandara, Jayasundera

    2018-07-01

    Dielectric oxide materials are well-known insulators that have many applications in catalysis as well as in device manufacturing industries. However, these dielectric materials cannot be employed directly in photochemical reactions that are initiated by the absorption of UV-Vis photons. Despite their insensitivity to solar energy, dielectric materials can be made sono-photoactive even for low energy IR photons by modifications of the interfacial properties of dielectric materials by noble metals and metal oxides. In this investigation, by way of interface modification of dielectric MgO nanoparticles by Ag metal and Ag 2 O nanoparticles, IR photon initiated sono-photocatalytic activity of MgO is reported. The observed photocatalytic activity is found to be the synergic action of both IR light and sonication effect and sonication assisted a multi-step, sub-bandgap excitation of electrons in the MgO is proposed for the observed catalytic activity of Ag/Ag 2 O coated MgO nanoparticles. Our investigation reveals that other dielectric materials such as silver coated SiO 2 and Al 2 O 3 also exhibit IR active sono-photocatalytic activity. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Sono-photo-Fenton oxidation of bisphenol-A over a LaFeO3 perovskite catalyst.

    PubMed

    Dükkancı, Meral

    2018-01-01

    In this study, oxidation of bisphenol-A (IUPAC name - 2,2-(4,4-dihydroxyphenyl, BPA), which is an endocrine disrupting phenolic compound used in the polycarbonate plastic and epoxy resin industry, was investigated using sono-photo-Fenton process under visible light irradiation in the presence of an iron containing perovskite catalyst, LaFeO 3 . The catalyst prepared by sol-gel method, calcined at 500°C showed a catalytic activity in BPA oxidation using sono-photo-Fenton process with a degradation degree and a chemical oxygen demand (COD) reduction of 21.8% and 11.2%, respectively. Degradation of BPA was studied by using individual and combined advanced oxidation techniques including sonication, heterogeneous Fenton reaction and photo oxidation over this catalyst to understand the effect of each process on degradation of BPA. It was seen, the role of sonication was very important in hybrid sono-photo-Fenton process due to the pyrolysis and sonoluminescence effects caused by ultrasonic irradiation. The prepared LaFeO 3 perovskite catalyst was a good sonocatalyst rather than a photocatalyst. Sonication was not only the effective process to degrade BPA but also it was the cost effective process in terms of energy consumption. The studies show that the energy consumption is lower in the sono-Fenton process than those in the photo-Fenton and sono-photo- Fenton processes. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Sono-assisted adsorption of a textile dye on milk vetch-derived charcoal supported by silica nanopowder.

    PubMed

    Jorfi, Sahand; Darvishi Cheshmeh Soltani, Reza; Ahmadi, Mehdi; Khataee, Alireza; Safari, Mahdi

    2017-02-01

    This study was performed to assess the efficiency of silica nanopowder (SNP)/milk vetch-derived charcoal (MVDC) nanocomposite coupled with the ultrasonic irradiation named sono-adsorption process for treating water-contained Basic Red 46 (BR46) dye. Field emission scanning electron microscopy (FE-SEM), X-ray diffraction (XRD), Brunauer-Emmett-Teller (BET) and Fourier transform infrared spectroscopy (FT-IR) were performed for the characterization of as-prepared adsorbent. The sono-assisted adsorption process was optimized using response surface optimization on the basis of central composite design by the application of quadratic model. Accordingly, the color removal can be retained more than 93% by an initial BR46 concentration of 8 mg/L, sonication time of 31 min, adsorbent dosage of 1.2 g/L and initial pH of 9. The pseudo-second order kinetic model described the sono-assisted adsorption of BR46 reasonably well (R 2  > 0.99). The intra-particular diffusion kinetic model pointed out that the sono-assisted adsorption of BR46 onto SNP/MVDC nanocomposite was diffusion controlled as well as that ultrasonication enhanced the diffusion rate. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Sono-electro-magnetic therapy for treating chronic pelvic pain syndrome in men: a randomized, placebo-controlled, double-blind trial.

    PubMed

    Kessler, Thomas M; Mordasini, Livio; Weisstanner, Christian; Jüni, Peter; da Costa, Bruno R; Wiest, Roland; Thalmann, George N

    2014-01-01

    To assess the efficacy and safety of sono-electro-magnetic therapy compared to placebo in men with refractory CPPS. In a randomized, placebo-controlled, double-blind single center trial, we assessed the effect of sono-electro-magnetic therapy in men with treatment refractory CPPS. Sixty male patients were randomly assigned to treatment with either sono-electro-magnetic (n = 30) or placebo therapy (n = 30) for 12 weeks. The primary outcome was a change in the National Institutes of Health Chronic Prostatitis Symptom Index (NIH-CPSI) from baseline to 12 weeks. The 12-week difference between sono-electro-magnetic and placebo therapy in changes of the NIH-CPSI total score was -3.1 points (95% CI -6.8 to 0.6, p = 0.11). In secondary comparisons of NIH-CPSI sub-scores, we found differences between groups most pronounced for the quality-of-life sub-score (difference at 12 weeks -1.6, 95% CI -2.8 to -0.4, p = 0.015). In stratified analyses, the benefit of sono-electro-magnetic therapy appeared more pronounced among patients who had a symptom duration of 12 months or less (difference in NIH-CPSI total score -8.3, 95% CI -14.5 to 2.6) than in patients with a longer symptom duration (-0.8, 95% CI -4.6 to 3.1; p for interaction = 0.023). Sono-electro-magnetic therapy did not result in a significant improvement of symptoms in the overall cohort of treatment refractory CPPS patients compared to placebo treatment. Subgroup analysis indicates, however, that patients with a symptom-duration of 12 months or less may benefit from sono-electro-magnetic therapy, warranting larger randomized controlled trials in this subpopulation. ClinicalTrials.gov NCT00688506.

  12. Sono assisted electrocoagulation process for the removal of pollutant from pulp and paper industry effluent.

    PubMed

    Asaithambi, P; Aziz, Abdul Raman Abdul; Sajjadi, Baharak; Daud, Wan Mohd Ashri Bin Wan

    2017-02-01

    In the present work, the efficiency of the sonication, electrocoagulation, and sono-electrocoagulation process for removal of pollutants from the industrial effluent of the pulp and paper industry was compared. The experimental results showed that the sono-electrocoagulation process yielded higher pollutant removal percentage compared to the sonication and electrocoagulation process alone. The effect of the operating parameters in the sono-electrocoagulation process such as electrolyte concentration (1-5 g/L), current density (1-5 A/dm 2 ), effluent pH (3-11), COD concentration (1500-6000 mg/L), inter-electrode distance (1-3 cm), and electrode combination (Fe and Al) on the color removal, COD removal, and power consumption were studied. The maximum color and COD removal percentages of 100 and 95 %, respectively, were obtained at the current density of 4 A/dm 2 , electrolyte concentration of 4 g/L, effluent pH of 7, COD concentration of 3000 mg/L, electrode combination of Fe/Fe, inter-electrode distance of 1 cm, and reaction time of 4 h, respectively. The color and COD removal percentages were analyzed by using an UV/Vis spectrophotometer and closed reflux method. The results showed that the sono-electrocoagulation process could be used as an efficient and environmental friendly technique for complete pollutant removal.

  13. [Effectiveness of school-based interventions to prevent traffic accidents: an overview of secondary literature].

    PubMed

    Guerriero, Chiara; Verdina, Federico; Ferri, Chiara; Pizzaguerra, Martina; Silvestri, Silvia; Tober, Nastassja; Ristagno, Quenya; Costa, Alessandro; Cerasuolo, Michele; Faggiano, Fabrizio; Allara, Elias

    2016-01-01

    INTRODUZIONE: gli incidenti stradali sono l'ottava causa di morte al mondo e la prima tra i giovani di 15-29 anni. In Italia il Piano nazionale sicurezza stradale raccomanda l'educazione scolastica per la prevenzione degli incidenti stradali; ad oggi non esistono documenti che raccolgano evidenze di efficacia sugli interventi educativi stradali e le rapportino al contesto italiano. OBIETTIVI: riassumere e discutere ciò che è noto in letteratura riguardo agli interventi scolastici per la prevenzione degli incidenti stradali. METODI: sono state ricercate linee guida e revisioni sistematiche usando i seguenti criteri di inclusione: popolazione di età inferiore ai 25 anni di entrambi i sessi; interventi scolastici di educazione stradale; effetti su indicatori primari di esito come riduzione degli incidenti stradali, astinenza dalla guida sotto l'effetto di alcol e dall'accettare passaggi in macchina da guidatori che sono sotto l'effetto di alcol; effetti su indicatori secondari di esito come conoscenze e competenze sui comportamenti di guida sicura. RISULTATI: sono state identificate due revisioni sistematiche. L'educazione stradale nelle scuole non mostra evidenza di efficacia (rischio relativo 1,03; IC95% 0,98-1,08) nel ridurre gli incidenti. Programmi scolastici più specifici mostrano risultati solo in parte convincenti per l'adozione di comportamenti sicuri come l'astinenza dal guidare sotto l'effetto di alcol e dall'accettare passaggi in macchina da guidatori che sono sotto l'effetto di alcol. DISCUSSIONE: le revisioni incluse non hanno trovato programmi efficaci nella riduzione degli incidenti stradali o dei fattori che possano determinarli. Nell'attesa di studi più recenti, appare opportuno promuovere l'implementazione di interventi misti, scolastici e di comunità, che hanno mostrato maggiori prove di efficacia.

  14. Conductive diamond sono-electrochemical disinfection (CDSED) for municipal wastewater reclamation.

    PubMed

    Llanos, Javier; Cotillas, Salvador; Cañizares, Pablo; Rodrigo, Manuel A

    2015-01-01

    In the present work, the disinfection of actual effluents from a municipal wastewater treatment plant (WWTP) by a conductive diamond sono-electrochemical process was assessed. First, efficiency of single electrodisinfection process with diamond anodes (without the contribution of ultrasounds) was studied, finding that the total disinfection can be attained at current charges applied below 0.02kAhm(-3). It was also found that the main disinfection mechanism is the attack of Escherichia coli (E. coli) by the disinfectants produced in the electrochemical cell and that the production of chlorates is avoided when working at current densities not higher than 1.27Am(-2). Next, a marked synergistic effect was found when coupling ultrasound (US) irradiation to the electrochemical system (sono-electrochemical disinfection). This increase in the disinfection rate was found to be related to the suppression of the agglomeration of E. coli cells and the enhancement in the production of disinfectant species. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Investigation and process optimization of SONOS cell's drain disturb in 2-transistor structure flash arrays

    NASA Astrophysics Data System (ADS)

    Xu, Zhaozhao; Qian, Wensheng; Chen, Hualun; Xiong, Wei; Hu, Jun; Liu, Donghua; Duan, Wenting; Kong, Weiran; Na, Wei; Zou, Shichang

    2017-03-01

    The mechanism and distribution of drain disturb (DD) are investigated in silicon-oxide-nitride-oxide-silicon (SONOS) flash cells. It is shown that DD is the only concern in this paper. First, the distribution of trapped charge in nitride layer is found to be non-localized (trapped in entire nitride layer along the channel) after programming. Likewise, the erase is also non-localized. Then, the main disturb mechanism: Fowler Nordheim tunneling (FNT) has been confirmed in this paper with negligible disturb effect from hot-hole injection (HHI). And then, distribution of DD is confirmed to be non-localized similarly, which denotes that DD exists in entire tunneling oxide (Oxide for short). Next, four process optimization ways are proposed for minimization of DD, and VTH shift is measured. It reveals that optimized lightly doped drain (LDD), halo, and channel implant are required for the fabrication of a robust SONOS cell. Finally, data retention and endurance of the optimized SONOS are demonstrated.

  16. Functions of Discourse Markers "Ano and Sono" in Written Dialogue.

    ERIC Educational Resources Information Center

    Fujita, Yasuko

    Through examination of the discourse markers "ano" and "sono" in Japanese, this paper explores how these linguistic devices function differently in conversation. The focus of this analysis is the mental and social functions through which a speaker attempts to achieve an interpersonal rapport with a listener. In particular, the…

  17. Charge retention in scaled SONOS nonvolatile semiconductor memory devices—Modeling and characterization

    NASA Astrophysics Data System (ADS)

    Hu, Yin; White, Marvin H.

    1993-10-01

    A new analytical model is developed to investigate the influence of the charge loss processes in the retention mode of the SONOS NVSM device. The model considers charge loss by the following processes: (1) electron back-tunneling from the nitride traps to the Si conduction band, (2) electron back-tunneling from the nitride traps to the Si/SiO 2 interface traps and (3) hole injection from the Si valence band to the nitride traps. An amphoteric trap charge distribution is used in this model. The new charge retention model predicts that process (1) determines the short term retention, while processes (2) and (3) determine the long term retention. Good agreement has been reached between the results of analytical calculations and the experimental retention data on both surface channel and buried channel SONOS devices.

  18. Mechanistic investigations in sono-hybrid techniques for rice straw pretreatment.

    PubMed

    Suresh, Kelothu; Ranjan, Amrita; Singh, Shuchi; Moholkar, Vijayanand S

    2014-01-01

    This paper reports comparative study of two chemical techniques (viz. dilute acid/alkali treatment) and two physical techniques (viz. hot water bath and autoclaving) coupled with sonication, termed as sono-hybrid techniques, for hydrolysis of rice straw. The efficacy of each sono-hybrid technique was assessed on the basis of total sugar and reducing sugar release. The system of biomass pretreatment is revealed to be mass transfer controlled. Higher sugar release is obtained during dilute acid treatment than dilute alkali treatment. Autoclaving alone was found to increase sugar release marginally as compared to hot water bath. Sonication of the biomass solution after autoclaving and stirring resulted in significant rise of sugar release, which is attributed to strong convection generated during sonication that assists effective transport of sugar molecules. Discrimination between individual contributions of ultrasound and cavitation to mass transfer enhancement reveals that contribution of ultrasound (through micro-streaming) is higher. Micro-turbulence as well as acoustic waves generated by cavitation did not contribute much to enhancing of mass transfer in the system. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. FEM simulation of a sono-reactor accounting for vibrations of the boundaries.

    PubMed

    Louisnard, O; Gonzalez-Garcia, J; Tudela, I; Klima, J; Saez, V; Vargas-Hernandez, Y

    2009-02-01

    The chemical effects of acoustic cavitation are obtained in sono-reactors built-up from a vessel and an ultrasonic source. In this paper, simulations of an existing sono-reactor are carried out, using a linear acoustics model, accounting for the vibrations of the solid walls. The available frequency range of the generator (19-21 kHz) is systematically scanned. Global quantities are plotted as a function of frequency in order to obtain response curves, exhibiting several resonance peaks. In absence of the precise knowledge of the bubbles size distribution and spatial location, the attenuation coefficient of the wave is taken as a variable, but spatially uniform parameter, and its influence is studied. The concepts of acoustic energy, intensity, active power, and source impedance are recalled, along with the general balance equation for acoustic energy, which is used as a convergence check of the simulations. It is shown that the interface between the liquid and the solid walls cannot be correctly represented by the simple approximations of either infinitely soft, or infinitely hard boundaries. Moreover, the liquid-solid coupling allows the cooling jacket to receive a noticeable part of the input power, although it is not in direct contact with the sonotrode. It may therefore undergo cavitation and this feature opens the perspective to design sono-reactors which avoid direct contact between the working liquid and the sonotrode. Besides, the possibility to shift the main pressure antinode far from the sonotrode area by exciting a resonance of the system is examined.

  20. Treating soil-washing fluids polluted with oxyfluorfen by sono-electrolysis with diamond anodes.

    PubMed

    Vieira Dos Santos, E; Sáez, C; Cañizares, P; Martínez-Huitle, C A; Rodrigo, M A

    2017-01-01

    This works is focused on the treatment by sono-electrolysis of the liquid effluents produced during the Surfactant-Aided Soil-Washing (SASW) of soils spiked with herbicide oxyfluorfen. Results show that this combined technology is very efficient and attains the complete mineralization of the waste, regardless of the surfactant/soil radio applied in the SASW process (which is the main parameter of the soil remediation process and leads to very different wastes). Both the surfactant and the herbicide are completely degraded, even when single electrolysis is used; and only two intermediates are detected by HPLC in very low concentrations. Conversely, the efficiency of single sonolysis approach, for the oxidation of pollutant, is very low and just small changes in the herbicides and surfactant concentrations are observed during the tests carried out. Sono-electrolysis with diamond electrodes achieved higher degradation rates than those obtained by single sonolysis and/or single electrolysis with diamond anodes. A key role of sulfate is developed, when it is released after the electrochemical degradation of surfactant. The efficient catalytic effect observed which can be explained by the anodic formation of persulfate and the later, a sono-activation is attained to produce highly efficient sulfate radicals. The effect of irradiating US is more importantly observed in the pesticide than in the surfactant, in agreement with the well-known behavior of these radicals which are known to oxidize more efficiently aromatic compounds than aliphatic species. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Enhanced photo-, sono- and sonophotocatalysis of methylene blue via SnO2 nanoparticle supported on nanographene platelets (NGP)

    NASA Astrophysics Data System (ADS)

    Paramarta, V.; Taufik, A.; Saleh, R.

    2017-07-01

    In our previous study, we have reported the catalytic (photo- and sono-) performance of SnO2 nanoparticles in methylene blue (MB) removal from aqueous solution. In this study, SnO2/nanographene platelets (NGP) composites were fabricated by depositing SnO2 nanoparticle onto nanographene platelets surface to develop photo-, sono-, and sonophotocatalysts, SnO2 nanoparticle, and SnO2/NGP composites were successfully synthesized using the sol-gel and coprecipitation method, respectively. The nanographene platelets (NGP) content was varied from 5, 10, and 15 weight percentages (wt.%). The optical properties and thermal stability of the samples were characterized using X-ray Diffraction (XRD), Fourier Transform Infrared (FTIR), and Thermal Gravimetric Analysis (TGA). The catalytic ability of the samples was investigated using photo-, sono-, and sonophoto degradation of MB which was observed when nanographene platelets (NGP) were added into SnO2 nanocomposite. The photo-, sono- and sonophotocatalytic activities of SnO2/NGP composites on dyes were analyzed by measuring the change in absorbance of dyes under UV-spectrophotometer. The degradation of the organic dyes has been calculated by monitoring the degradation in concentration of the dyes before and after irradiation of UV light, ultrasound, and both of them respectively. The influence of other parameters such as catalyst dosage, pH, and scavenger have also been investigated. The results showed that SnO2/NGP composite with 10 weight percent (wt.%) has better catalytic performance than pure SnO2 nanoparticle. The reusability tests have also been done to ensure the stability of the used catalysts.

  2. Sono-elastography for Differentiating Benign and Malignant Cervical Lymph Nodes: A Systematic Review and Meta-Analysis.

    PubMed

    Ghajarzadeh, Mahsa; Mohammadifar, Mehdi; Azarkhish, Kamran; Emami-Razavi, Seyed Hassan

    2014-12-01

    We did this systematic review to determine diagnostic accuracy of sono-elastography in evaluating cervical lymph nodes (LNs). A highly sensitive search for sono-elastography and LNs was performed in MEDLINE, Cochrane Library, ACP Journal Club, EMBASE, Health Technology assessment, and ISI web of knowledge for studies published prior to December 2012. SPSS version 18 (SPSS Inc., Chicago, IL, USA) used for descriptive analysis and meta-disk version 1.4 applied for meta-analysis. Forest plots for pooled estimates and summery of receiver operating characteristic plots for different cut-offs were produced. The literature and manual search yielded 69 articles, of which 10 were eligible to include. A total of 578 individuals with a total number of 936 cervical LNs was evaluated (502 malignant and 434 benign). The summary sensitivity of the scoring and strain ratio (SR) measurements for the differentiation of benign and malignant LNs were 0.76 (95% CI: 0.71-0.8) and 0.83 (95% CI: 0.78-0.87). The summary specificities were 0.8 (95% confidence interval [CI]: 0.75-0.84) and 0.84 (95% CI: 0.79-0.88), respectively. Area under the curve for scoring system was 0.86 (standard error [SE] = 0.03) and 0.95 (SE = 0.02) for SR measurement. Sono-elastograohy has high accuracy in differentiating benign and malignant cervical LNs.

  3. Sono-elastography for Differentiating Benign and Malignant Cervical Lymph Nodes: A Systematic Review and Meta-Analysis

    PubMed Central

    Ghajarzadeh, Mahsa; Mohammadifar, Mehdi; Azarkhish, Kamran; Emami-Razavi, Seyed Hassan

    2014-01-01

    We did this systematic review to determine diagnostic accuracy of sono-elastography in evaluating cervical lymph nodes (LNs). A highly sensitive search for sono-elastography and LNs was performed in MEDLINE, Cochrane Library, ACP Journal Club, EMBASE, Health Technology assessment, and ISI web of knowledge for studies published prior to December 2012. SPSS version 18 (SPSS Inc., Chicago, IL, USA) used for descriptive analysis and meta-disk version 1.4 applied for meta-analysis. Forest plots for pooled estimates and summery of receiver operating characteristic plots for different cut-offs were produced. The literature and manual search yielded 69 articles, of which 10 were eligible to include. A total of 578 individuals with a total number of 936 cervical LNs was evaluated (502 malignant and 434 benign). The summary sensitivity of the scoring and strain ratio (SR) measurements for the differentiation of benign and malignant LNs were 0.76 (95% CI: 0.71–0.8) and 0.83 (95% CI: 0.78–0.87). The summary specificities were 0.8 (95% confidence interval [CI]: 0.75–0.84) and 0.84 (95% CI: 0.79–0.88), respectively. Area under the curve for scoring system was 0.86 (standard error [SE] = 0.03) and 0.95 (SE = 0.02) for SR measurement. Sono-elastograohy has high accuracy in differentiating benign and malignant cervical LNs. PMID:25709787

  4. Enhancing the anaerobic digestion potential of dairy waste activated sludge by two step sono-alkalization pretreatment.

    PubMed

    Rani, R Uma; Kumar, S Adish; Kaliappan, S; Yeom, Ick-Tae; Banu, J Rajesh

    2014-05-01

    High efficiency resource recovery from dairy waste activated sludge (WAS) has been a focus of attention. An investigation into the influence of two step sono-alkalization pretreatment (using different alkaline agents, pH and sonic reaction times) on sludge reduction potential in a semi-continuous anaerobic reactor was performed for the first time in literature. Firstly, effect of sludge pretreatment was evaluated by COD solubilization, suspended solids reduction and biogas production. At optimized condition (4172 kJ/kg TS of supplied energy for NaOH - pH 10), COD solubilization, suspended solids reduction and biogas production was 59%, 46% and 80% higher than control. In order to clearly describe the hydrolysis of waste activated sludge during sono-alkalization pretreatment by a two step process, concentrations of ribonucleic acid (RNA) and bound extracellular polymeric substance (EPS) were also measured. Secondly, semi-continuous process performance was studied in a lab-scale semi-continuous anaerobic reactor (5L), with 4 L working volume. With three operated SRTs, the SRT of 15 d was found to be most appropriate for economic operation of the reactor. Combining pretreatment with anaerobic digestion led to 58% and 62% of suspended solids and volatile solids reduction, respectively, with an improvement of 83% in biogas production. Thus, two step sono-alkalization pretreatment laid the basis in enhancing the anaerobic digestion potential of dairy WAS. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. A SONOS device with a separated charge trapping layer for improvement of charge injection

    NASA Astrophysics Data System (ADS)

    Ahn, Jae-Hyuk; Moon, Dong-Il; Ko, Seung-Won; Kim, Chang-Hoon; Kim, Jee-Yeon; Kim, Moon-Seok; Seol, Myeong-Lok; Moon, Joon-Bae; Choi, Ji-Min; Oh, Jae-Sub; Choi, Sung-Jin; Choi, Yang-Kyu

    2017-03-01

    A charge trapping layer that is separated from the primary gate dielectric is implemented on a FinFET SONOS structure. By virtue of the reduced effective oxide thickness of the primary gate dielectric, a strong gate-to-channel coupling is obtained and thus short-channel effects in the proposed device are effectively suppressed. Moreover, a high program/erase speed and a large shift in the threshold voltage are achieved due to the improved charge injection by the reduced effective oxide thickness. The proposed structure has potential for use in high speed flash memory.

  6. Sono-bromination of aromatic compounds based on the ultrasonic advanced oxidation processes.

    PubMed

    Fujita, Mitsue; Lévêque, Jean-Marc; Komatsu, Naoki; Kimura, Takahide

    2015-11-01

    A novel, mild "sono-halogenation" of various aromatic compounds with potassium halide was investigated under ultrasound in a biphasic carbon tetrachloride/water medium. The feasibility study was first undertaken with the potassium bromide and then extended to chloride and iodide analogues. This methodology could be considered as a new expansion of the ultrasonic advanced oxidation processes (UAOPs) into a synthetic aspect as the developed methodology is linked to the sonolytic disappearance of carbon tetrachloride. Advantages of the present method are not only that the manipulation of the bromination is simple and green, but also that the halogenating agents used are readily available, inexpensive, and easy-handling. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. [Health expenditure for prevention in Italy (2006-2013): descriptive analysis, regional trends and international comparisons].

    PubMed

    Signorelli, Carlo; Odone, Anna; Bianco, Daniela; Di Vivo, Natalia; Bevere, Francesco

    2016-01-01

    Il dato dell'Organizzazione per la cooperazione e lo sviluppo economico (OCSE) del 2012, che indicava l'Italia come il Paese con la più bassa spesa in prevenzione sanitaria, ha dato lo spunto per una raccolta sistematica e un'analisi critica dei flussi disponibili sulla spesa per le attività di prevenzione in Italia. Le statistiche correnti di spesa sanitaria sono raccolte centralmente dall'Agenzia nazionale per i servizi sanitari regionali (Agenas) attraverso i modelli di rilevazione dei costi dei livelli essenziali di assistenza (LEA) delle aziende USL. Le tre macroaree dei LEA sono: assistenza distrettuale, assistenza ospedaliera e assistenza sanitaria collettiva in ambiente di vita e di lavoro. Le spese per la prevenzione rientrano in quest'ultima e sono ripartite nelle seguenti voci: attività di prevenzione rivolte alle persone, igiene degli alimenti e della nutrizione, igiene e sanità pubblica, prevenzione e sicurezza negli ambienti di lavoro, sanità pubblica veterinaria, attività medico-legale per finalità pubblica. Tra il 2006 e il 2013, ultimo dato disponibile, la spesa per le attività di prevenzione del Servizio sanitario nazionale (SSN) è rimasta costante in rapporto alla spesa sanitaria totale (4,2%), pari a 4,9 miliardi nel 2013. Nel periodo di studio considerato (2006-2013) appaiono in aumento le spese per le attività rivolte alle persone (+8,7%), attribuibili soprattutto a vaccinazioni e screening, e in diminuzione le attività di igiene pubblica (-5,7%) e quelle della sanità pubblica veterinaria (-3,8%). I confronti internazionali indicano una spesa per la prevenzione del 2,9% rispetto alla spesa sanitaria totale, costante negli anni e nella media dei Paesi OCSE. Per la prevenzione, l'Italia spende tanto quanto i Paesi che non possiedono un servizio sanitario pubblico; il dato risulta inferiore del 5% rispetto alla programmazione nazionale, con poche eccezioni e molta variabilità regionale all'interno delle componenti delle voci di spesa

  8. Surface Charge Measurement of SonoVue, Definity and Optison: A Comparison of Laser Doppler Electrophoresis and Micro-Electrophoresis.

    PubMed

    Ja'afar, Fairuzeta; Leow, Chee Hau; Garbin, Valeria; Sennoga, Charles A; Tang, Meng-Xing; Seddon, John M

    2015-11-01

    Microbubble (MB) contrast-enhanced ultrasonography is a promising tool for targeted molecular imaging. It is important to determine the MB surface charge accurately as it affects the MB interactions with cell membranes. In this article, we report the surface charge measurement of SonoVue, Definity and Optison. We compare the performance of the widely used laser Doppler electrophoresis with an in-house micro-electrophoresis system. By optically tracking MB electrophoretic velocity in a microchannel, we determined the zeta potentials of MB samples. Using micro-electrophoresis, we obtained zeta potential values for SonoVue, Definity and Optison of -28.3, -4.2 and -9.5 mV, with relative standard deviations of 5%, 48% and 8%, respectively. In comparison, laser Doppler electrophoresis gave -8.7, +0.7 and +15.8 mV with relative standard deviations of 330%, 29,000% and 130%, respectively. We found that the reliability of laser Doppler electrophoresis is compromised by MB buoyancy. Micro-electrophoresis determined zeta potential values with a 10-fold improvement in relative standard deviation. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  9. Relationship of ultrasound signal intensity with SonoVue concentration at body temperature in vitro

    NASA Astrophysics Data System (ADS)

    Yang, Xin; Li, Jing; He, Xiaoling; Wu, Kaizhi; Yuan, Yun; Ding, Mingyue

    2014-04-01

    In this paper, the relationship between image intensity and ultrasound contrast agent (UCA) concentration is investigated. Experiments are conducted in water bath using a silicon tube filled with UCA (SonoVue) at different concentrations (100μl/l to 6000μl/l) at around 37 °C to simulate the temperature in human body. The mean gray-scale intensity within the region of interest (ROI) is calculated to obtain the plot of signal intensity to UCA concentration. The results show that the intensity firstly exhibits a linear increase to the peak at approximately 1500μl/l then appears a downward trend due to the multiple scattering (MS) effects.

  10. Sono- and photocatalytic activities of SnO2 nanoparticles for degradation of cationic and anionic dyes

    NASA Astrophysics Data System (ADS)

    Paramarta, Valentinus; Taufik, Ardiansyah; Munisa, Lusitra; Saleh, Rosari

    2017-01-01

    The current research work focuses on the catalytic activity of SnO2 nanoparticles (NPs) against degradation of both cationic dye (methylene blue) and anionic dye (Congo-red). SnO2 NPs were synthesized under the sol-gel method and were characterized by performing X-ray diffraction, Fourier Transform Infrared Spectroscopy (FT-IR), Transmission Electron Microscopy (TEM) Brunauer-Emmet-Teller (BET) surface area analysis and UV-Vis spectroscopy. The results demonstrate that SnO2 NPs has well crystalline structure with the crystallite size of 44 nm. The degradation of dyes was studied under ambient temperature using ultrasonicator and UV light, respectively. The sono- and photocatalytic activities of SnO2 NPs on dyes were analyzed by measuring the change in absorbance of dyes under UV-spectrophotometer. The degradation of the organic dyes has been calculated by monitoring the degradation in the concentration of the dyes before and after irradiation of ultrasonic and light, respectively. The influence of other parameters such as catalyst dosage, pH and scavenger have also been investigated. The catalytic activity is enhanced in the presence of ultrasonic irradiation. The degradation of both dyes follows pseudo-first order kinetics. The reusability tests have also been done to ensure the stability of the used catalysts. A reasonable mechanism of sono- and photocatalysis with SnO2 NPs has been proposed by correlating the active radical species involved with the physical properties of the as-synthesized samples.

  11. Sono-photoacoustic imaging of gold nanoemulsions: Part II. Real time imaging

    PubMed Central

    Arnal, Bastien; Wei, Chen-Wei; Perez, Camilo; Nguyen, Thu-Mai; Lombardo, Michael; Pelivanov, Ivan; Pozzo, Lilo D.; O’Donnell, Matthew

    2015-01-01

    Photoacoustic (PA) imaging using exogenous agents can be limited by degraded specificity due to strong background signals. This paper introduces a technique called sono-photoacoustics (SPA) applied to perfluorohexane nanodroplets coated with gold nanospheres. Pulsed laser and ultrasound (US) excitations are applied simultaneously to the contrast agent to induce a phase-transition ultimately creating a transient microbubble. The US field present during the phase transition combined with the large thermal expansion of the bubble leads to 20–30 dB signal enhancement. Aqueous solutions and phantoms with very low concentrations of this agent were probed using pulsed laser radiation at diagnostic exposures and a conventional US array used both for excitation and imaging. Contrast specificity of the agent was demonstrated with a coherent differential scheme to suppress US and linear PA background signals. SPA shows great potential for molecular imaging with ultrasensitive detection of targeted gold coated nanoemulsions and cavitation-assisted theranostic approaches. PMID:25893170

  12. [Studies on the degradation of paracetamol in sono-electrochemical oxidation].

    PubMed

    Dai, Qi-Zhou; Ma, Wen-Jiao; Shen, Hong; Chen, Jun; Chen, Jian-Meng

    2012-07-01

    A novel lead dioxide electrodes co-doped with rare earth and polytetrafluoroethylene (PTFE) were prepared by the electrode position method and applied as anodes in sono-electrochemical oxidation for pharmaceutical wastewater degradation. The results showed that the APAP removal and the mineralization efficiency reached an obvious increase, which meant that the catalytic efficiency showed a significant improvement in the use of rare-earth doped electrode. The effects of process factors showed that the condition of the electrode had the best degradation efficiency with doped with Ce2O3 under electrolyte concentration of 14.2 g x L(-1), 49.58 W x cm(-2), 50 Hz, pH = 3, 71.43 mA x cm(-2). The APAP of 500 mg x L(-1) removal rate reached 92.20% and its COD and TOC values declined to 79.95% and 58.04%, the current efficiency reached 45.83% after degradation process for 2.0 h. The intermediates were monitored by the methods of GC-MS, HPLC, and IC. The main intermediates of APAP were p-benzoquinone, benzoic acid, acetic acid, maleic acid, oxalic acid, formic acid etc, and the final products were carbon dioxide and water. The goal of completely degradation of pollutant was achieved and a possible degradation way was proposed.

  13. Comparison of transducers with different frequencies in breast contrast-enhanced ultrasound (CEUS) using SonoVue as contrast agent.

    PubMed

    Wang, Yong-Mei; Fan, Wei; Zhang, Kai; Zhang, Li; Tan, Zhen; Ma, Rong

    2016-07-01

    To explore the effectiveness of different transducers in breast contrast-enhanced ultrasound (CEUS) using SonoVue(®) (Bracco, Plan-Les-Ouates, Switzerland) as the contrast agent. Breast CEUS was performed in 51 patients with 51 breast lesions using a low-frequency transducer (probe C5-1) and a high-frequency transducer (probe L12-5) separately. All image processes were reviewed for the presence of local blood perfusion defects and surrounding vessels. McNemar's test was conducted to compare the detection effectiveness between these two transducers. Pathological results revealed 38 malignant and 13 benign lesions. The two transducers showed no difference in detecting benign lesions. Among malignant lesions, CEUS conducted by probe C5-1 (frequency range from 1 to 5 MHz) presented 23 (60.5%) lesions with local blood perfusion defects and 26 (68.4%) lesions with surrounding vessels. Meanwhile, probe L12-5 (frequency range from 5 to 12 MHz) showed only 12 (31.6%) lesions with local blood perfusion defects and 12 (31.6%) lesions with surrounding vessel. Probe C5-1 was more sensitive than probe L12-5 in detecting malignant CEUS characteristics (p-value < 0.05). The low-frequency transducer was more sensitive than the high-frequency transducer in breast CEUS using SonoVue as the contrast agent. A new contrast agent with a higher resonance frequency, specially designed for high-frequency transducers, may be helpful in improving the clinical value of breast CEUS. The first study comparing different frequency transducers in breast CEUS of the same patient lesions. We brought out the requirement for CEUS contrast agents which are more suitable for high-frequency examinations.

  14. Heterogeneous sono-Fenton-like process using martite nanocatalyst prepared by high energy planetary ball milling for treatment of a textile dye.

    PubMed

    Dindarsafa, Mahsa; Khataee, Alireza; Kaymak, Baris; Vahid, Behrouz; Karimi, Atefeh; Rahmani, Amir

    2017-01-01

    High energy planetary ball milling was applied to prepare sono-Fenton nanocatalyst from natural martite (NM). The NM samples were milled for 2-6h at the speed of 320rpm for production of various ball milled martite (BMM) samples. The catalytic performance of the BMMs was greater than the NM for treatment of Acid Blue 92 (AB92) in heterogeneous sono-Fenton-like process. The NM and the BMM samples were characterized by XRD, FT-IR, SEM, EDX and BET analyses. The particle size distribution of the 6h-milled martite (BMM 3 ) was in the range of 10-90nm, which had the highest surface area compared to the other samples. Then, the impact of main operational parameters was investigated on the process. Complete removal of the dye was obtained at the desired conditions including initial pH 7, 2.5g/L BMM 3 dosage, 10mg/L AB92 concentration, and 150W ultrasonic power after 30min of treatment. The treatment process followed pseudo-first order kinetic. Environmentally-friendly modification of the NM, low leached iron amount and repeated application at milder pH were the significant benefits of the BMM 3 . The GC-MS was successfully used to identify the generated intermediates. Eventually, an artificial neural network (ANN) was applied to predict the AB92 removal efficiency based upon the experimental data with a proper correlation coefficient (R 2 =0.9836). Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Multi-objective optimization of oxidative desulfurization in a sono-photochemical airlift reactor.

    PubMed

    Behin, Jamshid; Farhadian, Negin

    2017-09-01

    Response surface methodology (RSM) was employed to optimize ultrasound/ultraviolet-assisted oxidative desulfurization in an airlift reactor. Ultrasonic waves were incorporated in a novel-geometry reactor to investigate the synergistic effects of sono-chemistry and enhanced gas-liquid mass transfer. Non-hydrotreated kerosene containing sulfur and aromatic compounds was chosen as a case study. Experimental runs were conducted based on a face-centered central composite design and analyzed using RSM. The effects of two categorical factors, i.e., ultrasound and ultraviolet irradiation and two numerical factors, i.e., superficial gas velocity and oxidation time were investigated on two responses, i.e., desulfurization and de-aromatization yields. Two-factor interaction (2FI) polynomial model was developed for the responses and the desirability function associate with overlay graphs was applied to find optimum conditions. The results showed enhancement in desulfurization ability corresponds to more reduction in aromatic content of kerosene in each combination. Based on desirability approach and certain criteria considered for desulfurization/de-aromatization, the optimal desulfurization and de-aromatization yields of 91.7% and 48% were obtained in US/UV/O 3 /H 2 O 2 combination, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Development of a Sono-Assembled, Bifunctional Soy Peptide Nanoparticle for Cellular Delivery of Hydrophobic Active Cargoes.

    PubMed

    Zhang, Yuanhong; Zhao, Mouming; Ning, Zhengxiang; Yu, Shujuan; Tang, Ning; Zhou, Feibai

    2018-04-25

    Soy proteins are prone to aggregate upon proteolysis, hindering their sustainable development in food processing. Here, a continuous work on the large insoluble peptide aggregates was carried out, aiming to develop a new type of soy peptide-based nanoparticle (SPN) for active cargo delivery. Sono-assembled SPN in spherical appearance and core-shell structure maintained by noncovalent interactions was successfully fabricated, exhibiting small particle size (103.95 nm) in a homogeneous distribution state (PDI = 0.18). Curcumin as a model cargo was efficiently encapsulated into SPN upon sonication, showing high water dispersity (129.6 mg/L, 10 4 higher than its water solubility) and storage stability. Additionally, the pepsin-resistant SPN contributed to the controlled release of curcumin at the intestinal phase and thus significantly improved the bioaccessibility. Encapsulated curcumin was effective in protecting glutamate-induced toxicity in PC12 cells, where the matrix SPN can simultaneously reduce lipid peroxidation and elevate antioxidant enzymes levels, innovatively demonstrating its bifunctionality during cellular delivery.

  17. Polypyrrole coated phase-change contrast agents for sono-photoacoustic imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Li, David S.; Yoon, Soon Joon; Matula, Thomas J.; O'Donnell, Matthew; Pozzo, Lilo D.

    2017-03-01

    A new light and sound sensitive nanoemulsion contrast agent is presented. The agents feature a low boiling point liquid perfluorocarbon core and a broad light spectrum absorbing polypyrrole (PPy) polymer shell. The PPy coated nanoemulsions can reversibly convert from liquid to gas phase upon cavitation of the liquid perfluorocarbon core. Cavitation can be initiated using a sufficiently high intensity acoustic pulse or from heat generation due to light absorption from a laser pulse. The emulsions can be made between 150 and 350 nm in diameter and PPy has a broad optical absorption covering both the visible spectrum and extending into the near-infrared spectrum (peak absorption 1053 nm). The size, structure, and optical absorption properties of the PPy coated nanoemulsions were characterized and compared to PPy nanoparticles (no liquid core) using dynamic light scattering, ultraviolet-visible spectrophotometry, transmission electron microscopy, and small angle X-ray scattering. The cavitation threshold and signal intensity were measured as a function of both acoustic pressure and laser fluence. Overlapping simultaneous transmission of an acoustic and laser pulse can significantly reduce the activation energy of the contrast agents to levels lower than optical or acoustic activation alone. We also demonstrate that simultaneous light and sound cavitation of the agents can be used in a new sono-photoacoustic imaging method, which enables greater sensitivity than traditional photoacoustic imaging.

  18. Preparation of zeolite nanorods by corona discharge plasma for degradation of phenazopyridine by heterogeneous sono-Fenton-like process.

    PubMed

    Khataee, Alireza; Rad, Tannaz Sadeghi; Vahid, Behrouz; Khorram, Sirous

    2016-11-01

    The plasma-modified clinoptilolite (PMC) nanorods were prepared from natural clinoptilolite (NC) utilizing environmentally-friendly corona discharge plasma. The PMC and NC were characterized by XRD, FT-IR, SEM, EDX, XPS and BET, which confirmed the nanocatalyst formation. The catalytic performance of the PMC in the heterogeneous sono-Fenton-like process was greater than the NC for treatment of phenazopyridine (PhP). The desired amounts were obtained for experimental parameters including initial pH (5), PMC dosage (2g/L), K2S2O8 concentration (2mmol/L), ultrasonic power (300W) and PhP concentration (10mg/L). Reactive oxygen species scavengers decreased the removal efficiency of the PhP. The treatment process followed pseudo-first order kinetic and seven degradation intermediates were identified by the GC-MS technique. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. High performance SONOS flash memory with in-situ silicon nanocrystals embedded in silicon nitride charge trapping layer

    NASA Astrophysics Data System (ADS)

    Lim, Jae-Gab; Yang, Seung-Dong; Yun, Ho-Jin; Jung, Jun-Kyo; Park, Jung-Hyun; Lim, Chan; Cho, Gyu-seok; Park, Seong-gye; Huh, Chul; Lee, Hi-Deok; Lee, Ga-Won

    2018-02-01

    In this paper, SONOS-type flash memory device with highly improved charge-trapping efficiency is suggested by using silicon nanocrystals (Si-NCs) embedded in silicon nitride (SiNX) charge trapping layer. The Si-NCs were in-situ grown by PECVD without additional post annealing process. The fabricated device shows high program/erase speed and retention property which is suitable for multi-level cell (MLC) application. Excellent performance and reliability for MLC are demonstrated with large memory window of ∼8.5 V and superior retention characteristics of 7% charge loss for 10 years. High resolution transmission electron microscopy image confirms the Si-NC formation and the size is around 1-2 nm which can be verified again in X-ray photoelectron spectroscopy (XPS) where pure Si bonds increase. Besides, XPS analysis implies that more nitrogen atoms make stable bonds at the regular lattice point. Photoluminescence spectra results also illustrate that Si-NCs formation in SiNx is an effective method to form deep trap states.

  20. Modeling the oxidation kinetics of sono-activated persulfate's process on the degradation of humic acid.

    PubMed

    Songlin, Wang; Ning, Zhou; Si, Wu; Qi, Zhang; Zhi, Yang

    2015-03-01

    Ultrasound degradation of humic acid has been investigated in the presence of persulfate anions at ultrasonic frequency of 40 kHz. The effects of persulfate anion concentration, ultrasonic power input, humic acid concentration, reaction time, solution pH and temperature on humic acid removal efficiency were studied. It is found that up to 90% humic acid removal efficiency was achieved after 2 h reaction. In this system, sulfate radicals (SO₄⁻·) were considered to be the mainly oxidant to mineralize humic acid while persulfate anion can hardly react with humic acid directly. A novel kinetic model based on sulfate radicals (SO₄⁻·) oxidation was established to describe the humic acid mineralization process mathematically and chemically in sono-activated persulfate system. According to the new model, ultrasound power, persulfate dosage, solution pH and reaction temperature have great influence on humic acid degradation. Different initial concentration of persulfate anions and humic acid, ultrasonic power, initial pH and reaction temperature have been discussed to valid the effectiveness of the model, and the simulated data showed new model had good agreement with the experiments data.

  1. Oxidative degradation of phenols in sono-Fenton-like systems upon high-frequency ultrasound irradiation

    NASA Astrophysics Data System (ADS)

    Aseev, D. G.; Sizykh, M. R.; Batoeva, A. A.

    2017-12-01

    The kinetics of oxidative degradation of phenol and chlorophenols upon acoustic cavitation in the megahertz range (1.7 MHz) is studied experimentally in model systems, and the involvement of in situ generated reactive oxygen species (ROSs) is demonstrated. The phenols subjected to high frequency ultrasound (HFUS) are ranked in terms of their rate of conversion: 2,4,6-trichlorophenol > 2,4-dichlorophenol 2-chlorophenol > 4-chlorophenol phenol. Oxidative degradation upon HFUS irradiation is most efficient at low concentrations of pollutants, due to the low steady-state concentrations of the in situ generated ROSs. A dramatic increase is observed in the efficiency of oxidation in several sonochemical oxidative systems (HFUS in combination with other chemical oxidative factors). The system with added Fe2+ (a sono-Fenton system) derives its efficiency from hydrogen peroxide generated in situ as a result of the recombination of OH radicals. The S2O8 2-/Fe2+/HFUS system has a synergetic effect on substrate oxidation that is attributed to a radical chain mechanism. In terms of the oxidation rates, degrees of conversion, and specific energy efficiencies of 4-chlorophenol oxidation based on the amount of oxidized substance per unit of expended energy the considered sonochemical oxidative systems form the series HFUS < S2O8 2-/HFUS < S2O8 2-/Fe2+/HFUS.

  2. A new sono-electrochemical method for enhanced detoxification of hydrophilic chloroorganic pollutants in water.

    PubMed

    Yasman, Yakov; Bulatov, Valery; Gridin, Vladimir V; Agur, Sabina; Galil, Noah; Armon, Robert; Schechter, Israel

    2004-09-01

    A new method for detoxification of hydrophilic chloroorganic pollutants in effluent water was developed, using a combination of ultrasound waves, electrochemistry and Fenton's reagent. The advantages of the method are exemplified using two target compounds: the common herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) and its derivative 2,4-dichlorophenol (2,4-DCP). The high degradation power of this process is due to the large production of oxidizing hydroxyl radicals and high mass transfer due to sonication. Application of this sono-electrochemical Fenton process (SEF) treatment (at 20 kHz) with quite a small current density, accomplished almost 50% oxidation of 2,4-D solution (300 ppm, 1.2 mM) in just 60 s. Similar treatments ran for 600 s resulted in practically full degradation of the herbicide; sizable oxidation of 2,4-DCP also occurs. The main intermediate compounds produced in the SEF process were identified. Their kinetic profile was measured and a chemical reaction scheme was suggested. The efficiency of the SEF process is tentatively much higher than the reference degradation methods and the time required for full degradation is considerably shorter. The SEF process maintains high performance up to concentrations which are higher than reference methods. The optimum concentration of Fe2+ ions required for this process was found to be of about 2 mM, which is lower than that in reference techniques. These findings indicate that SEF process may be an effective method for detoxification of environmental water.

  3. Sono-photo-degradation of carbamazepine in a thin falling film reactor: Operation costs in pilot plant.

    PubMed

    Expósito, A J; Patterson, D A; Monteagudo, J M; Durán, A

    2017-01-01

    The photo-Fenton degradation of carbamazepine (CBZ) assisted with ultrasound radiation (US/UV/H 2 O 2 /Fe) was tested in a lab thin film reactor allowing high TOC removals (89% in 35min). The synergism between the UV process and the sonolytic one was quantified as 55.2%. To test the applicability of this reactor for industrial purposes, the sono-photo-degradation of CBZ was also tested in a thin film pilot plant reactor and compared with a 28L UV-C conventional pilot plant and with a solar Collector Parabolic Compound (CPC). At a pilot plant scale, a US/UV/H 2 O 2 /Fe process reaching 60% of mineralization would cost 2.1 and 3.8€/m 3 for the conventional and thin film plant respectively. The use of ultrasound (US) produces an extra generation of hydroxyl radicals, thus increasing the mineralization rate. In the solar process, electric consumption accounts for a maximum of 33% of total costs. Thus, for a TOC removal of 80%, the cost of this treatment is about 1.36€/m 3 . However, the efficiency of the solar installation decreases in cloudy days and cannot be used during night, so that a limited flow rate can be treated. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Binary metal oxide nanoparticle incorporated composite multilayer thin films for sono-photocatalytic degradation of organic pollutants

    NASA Astrophysics Data System (ADS)

    Gokul, Paramasivam; Vinoth, Ramalingam; Neppolian, Bernaurdshaw; Anandhakumar, Sundaramurthy

    2017-10-01

    We report reduced graphene oxide (rGO) supported binary metal oxide (CuO-TiO2/rGO) nanoparticle (NP) incorporated multilayer thin films based on Layer-by-Layer (LbL) assembly for enhanced sono-photocatalytic degradation of methyl orange under exposure to UV radiation. Multilayer thin films were fabricated on glass and quartz slides, and investigated using scanning electron microscopy and UV-vis spectroscopy. The loading of catalyst NPs on the film resulted in the change of morphology of the film from smooth to rough with uniformly distributed NPs on the surface. The growth of the control and NP incorporated films followed a linear regime as a function of number of layers. The%degradation of methyl orange as a function of time was investigated by UV-vis spectroscopy and total organic carbon (TOC) measurements. Complete degradation of methyl orange was achieved within 13 h. The amount of NP loading in the film significantly influenced the%degradation of methyl orange. Catalyst reusability studies revealed that the catalyst thin films could be repeatedly used for up to five times without any change in photocatalytic activity of the films. The findings of the present study support that the binary metal oxide catalyst films reported here are very useful for continuous systems, and thus, making it an option for scale up.

  5. Physics and Materials Science of High Temperature Superconductors

    DTIC Science & Technology

    1989-08-26

    30 L. Tessler: Critical Currents in YBaCuO of Thin Films Obtained by Seguential Evaporation 11:30 - 12:00 D. Mitzi : Ogen and Ion Doping~in... Mitzi , L. W. Lombardo and A. Kapitulnik, Department of Applied Physics, Stanford University, U Stanford, CA; and S. S. Laderman, Circuit Technology

  6. Sono- and photoelectrocatalytic processes for the removal of ionic liquids based on the 1-butyl-3-methylimidazolium cation.

    PubMed

    Mena, Ismael F; Cotillas, Salvador; Díaz, Elena; Sáez, Cristina; Mohedano, Ángel F; Rodrigo, Manuel A

    2017-12-06

    In this work, sono- and photoelectrolysis of synthetic wastewaters polluted with the ionic liquids 1-Butyl-3-methylimidazolium acetate (BmimAc) and chloride (BmimCl) were investigated with diamond anodes. The results were compared to those attained by enhancing bare electrolysis with irradiation by UV light or with the application of high-frequency ultrasound (US). Despite its complex heterocyclic structure, the Bmim + cation was successfully depleted with the three technologies that were tested and was mainly transformed into four different organic intermediates, an inorganic nitrogen species and carbon dioxide. Regardless of the technology that was evaluated, removal of the heterocyclic ring is much less efficient (and much slower) than oxidation of the counter ion. In turn, the counter ion influences the rate of removal of the ionic liquid cation. Thus, the electrolysis and photoelectrolysis of BmimAc are much less efficient than sonoelectrolysis, but their differences become much less important in the case of BmimCl. In this later case, the most efficient technology is photoelectrolysis. This result is directly related to the generation of free radicals in the solution by irradiation of the electrochemical system with UV light, which contributes significantly to the removal of Bmim + . Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Sinoporphyrin sodium triggered sono-photodynamic effects on breast cancer both in vitro and in vivo.

    PubMed

    Liu, Yichen; Wang, Pan; Liu, Quanhong; Wang, Xiaobing

    2016-07-01

    Sono-photodynamic therapy (SPDT) is a promising anti-cancer strategy. Briefly, SPDT combines ultrasound and light to activate sensitizers that produce mechanical, sonochemical and photochemical activities. Sinoporphyrin sodium (DVDMS) is a newly identified sensitizer that shows great potential in both sonodynamic therapy (SDT) and photodynamic therapy (PDT). In this study, we primarily evaluated the combined effects of SDT and PDT by using DVDMS on breast cancer both in vitro and in vivo. In vitro, DVDMS-SPDT elicits much serious cytotoxicity compared with either SDT or PDT alone by MTT and colony formation assays. 2',7'-Dichlorodihydrofluo-rescein-diacetate (DCFH-DA) and dihydroethidium (DHE) staining revealed that intracellular reactive oxygen species (ROS) were significantly increased in groups given combined therapy. Terephthalic acid (TA) method and FD500-uptake assay reflected that cavitational effects and cell membrane permeability changes after ultrasound irradiation were also involved in the enhancement of combination therapy. In vivo, DVDMS-SPDT markedly inhibits the tumor volume and tumor weight growth. Hematoxylin-eosin staining and immunohistochemistry analysis show DVDMS-SPDT greatly suppressed tumor proliferation. Further, DVDMS-SPDT significantly inhibits tumor lung metastasis in the highly metastatic 4T1 mouse xenograft model, which is consistent well with the in vitro findings evaluated by transwell assay. Moreover, DVDMS-SPDT did not produces obvious effect on body weight and major organs in 4T1 xenograft model. The results suggest that by combination SDT and PDT, the sensitizer DVDMS would produce much better therapeutic effects, and DVDMS-SPDT may be a potential strategy against highly metastatic breast cancer. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. A modified method using the SonoPrep ultrasonic skin permeation system for sampling human interstitial fluid is compatible with proteomic techniques.

    PubMed

    Lecomte, Marie M J; Atkinson, Kelly R; Kay, Daniel P; Simons, Joanne L; Ingram, John R

    2013-02-01

    The use of biomarkers in skin is a novel diagnostic tool. Interstitial fluid (ISF) from skin provides a snapshot of proteins secreted at the time of sampling giving insights into the patient's health status. A minimally invasive technique for the transdermal collection of human ISF proteins. A low frequency ultrasonic skin permeation device (SonoPrep ultrasonic skin permeation system) was used to produce micropores in the stratum corneum through which ISF was extracted using a portable pulsed vacuum ISF collection device. On average, protein concentrations recovered ranged between 0.064 and 4.792 μg/μL (mean 1.258 μg/μL). Two-dimensional gel electrophoresis revealed that this sample type was amenable to this type of analysis. Gel images indicated that both highly abundant proteins and lower abundance proteins were isolated from the skin. Western blot analysis confirmed the presence of proteins commonly found in plasma and the epidermis. A minimally invasive method for the transdermal recovery of ISF proteins has been developed. We have demonstrated that ISF samples obtained using this approach can be analysed with proteomic techniques, such as two-dimensional gel electrophoresis and western blots, providing another tool for the identification of disease specific protein biomarkers. © 2012 John Wiley & Sons A/S.

  9. Preparation of TiO2-ZnO and its activity test in sonophotocatalytic degradation of phenol

    NASA Astrophysics Data System (ADS)

    Fatimah, Is; Novitasari

    2016-02-01

    Synthesis of TiO2-ZnO and its activity test in Sono photocatalysis degradation of phenol has been conducted. The synthesis was performed by the sol-gel mechanism by using titanium isopropoxide and zinc acetate as precursors with the Ti: Zn ratio of 5:1. Characterization of material were conducted by x-ray diffraction analysis, surface area analysis and also diffuse reflectance UV-Visible spectrophotometry. The material obtained from the synthesis was tested in photocatalysis, Sono catalysis and Sono photocatalysis degradation of phenol solution. Results showed that material exhibited the activity of varied mechanism o- phenol degradation. In advance, the Sono photocatalysis degradation produced the synergy index of 1.169 compared to both photocatalysis and Sono catalysis.

  10. A Model of a Sudden-Death Field-Goal Football Game as a Sequential Duel,

    DTIC Science & Technology

    1985-05-25

    AD-RI58 232 A MODEL OF A SUDDEN-DEATH FIEL-D-GOAL FOOTBALL GAME AS A 1/1 SEGUENTIAL DUEL .. (U) VALE UNIV NEW HAVEN CT COWIES FOUNDATION FOR RESEARCH...author to pro- tect the tentative character of these papers. A MODEL OF A SUDDEN-DEATH FIELD-GOAL FOOTBALL GAME LUJ-. j AS A SEQUENTIAL DUEL S -ELECTE...abstraction. Yet an interesting extension of the military dueling literature appears to be feasible. Rather than claim Immediate relevance to football as

  11. Multibit Polycristalline Silicon-Oxide-Silicon Nitride-Oxide-Silicon Memory Cells with High Density Designed Utilizing a Separated Control Gate

    NASA Astrophysics Data System (ADS)

    Rok Kim, Kyeong; You, Joo Hyung; Dal Kwack, Kae; Kim, Tae Whan

    2010-10-01

    Unique multibit NAND polycrystalline silicon-oxide-silicon nitride-oxide-silicon (SONOS) memory cells utilizing a separated control gate (SCG) were designed to increase memory density. The proposed NAND SONOS memory device based on a SCG structure was operated as two bits, resulting in an increase in the storage density of the NVM devices in comparison with conventional single-bit memories. The electrical properties of the SONOS memory cells with a SCG were investigated to clarify the charging effects in the SONOS memory cells. When the program voltage was supplied to each gate of the NAND SONOS flash memory cells, the electrons were trapped in the nitride region of the oxide-nitride-oxide layer under the gate to supply the program voltage. The electrons were accumulated without affecting the other gate during the programming operation, indicating the absence of cross-talk between two trap charge regions. It is expected that the inference effect will be suppressed by the lower program voltage than the program voltage of the conventional NAND flash memory. The simulation results indicate that the proposed unique NAND SONOS memory cells with a SCG can be used to increase memory density.

  12. Characteristics and Echogenicity of Clinical Ultrasound Contrast Agents: An In Vitro and In Vivo Comparison Study.

    PubMed

    Hyvelin, Jean-Marc; Gaud, Emmanuel; Costa, Maria; Helbert, Alexandre; Bussat, Philippe; Bettinger, Thierry; Frinking, Peter

    2017-05-01

    To compare physicochemical characteristics and in vitro and in vivo contrast-enhanced ultrasound imaging performance of 3 commercially available ultrasound contrast agents: SonoVue (Bracco Imaging SpA, Colleretto Giacosa, Italy; also marketed as Lumason in the USA), Definity (Lantheus Medical Imaging, North Billerica, MA) and Optison (GE Healthcare AS, Oslo, Norway). Physicochemical characteristics were measured with a Multisizer Coulter Counter (Beckman Coulter, Fullerton, CA). Two ultrasound systems (Aplio 500; Toshiba Medical Systems Corp, Tochigi-ken, Japan; and Logiq E9; GE Healthcare, Little Chalfont, England) were used with different transducers. Contrast enhancement was measured in vitro by dose-ranging measurements using a custom-built beaker setup; in vivo imaging performances were compared in pigs (heart and liver) and rabbits (liver). Quantitative analyses were performed with VueBox quantification software (Bracco Suisse SA, Plan-les-Ouates, Switzerland). Measured physicochemical characteristics were in agreement with those provided by the manufacturers. In vitro data demonstrated that the performance of SonoVue was similar to or better than that of Definity but superior to Optison (normalized scattered power 2- to 10-fold higher with SonoVue). Similar results were obtained in vivo, although the duration of enhancement in the pig heart was longer for SonoVue compared to Definity, and quantitative analysis revealed higher enhancement for SonoVue (1.5-fold increase). For liver imaging, SonoVue and Definity showed similar contrast enhancement and duration of enhancement, but compared to Optison, both peak enhancement and duration of enhancement were superior for SonoVue (up to 2-fold increase). Imaging performance of SonoVue was similar to or slightly better than that of Definity, but it was superior to Optison for the conditions used in this study. © 2017 by the American Institute of Ultrasound in Medicine.

  13. [La combinazione di gemcitabina e oxaliplatino (GEMOX) nel trattamento del carcinoma pancreatico in fase avanzata di malattia: le notizie sulla mia morte sono state esagerate?

    PubMed

    Giuliani, Jacopo; Bonetti, Andrea

    2017-12-01

    Riassunto. L'analisi è stata condotta al fine di valutare l'effetto sia sulla sopravvivenza globale (OS) sia sulla sopravvivenza libera da progressione di malattia (PFS) della chemioterapia di combinazione in prima linea per il carcinoma pancreatico in fase avanzata di malattia. La presente analisi è limitata agli studi randomizzati controllati (RCT) di fase III. Successivamente è stata applicata la European Society for Medical Oncology Magnitude of Clinical Benefit Scale (ESMO-MCBS) agli RCT di fase III analizzati per ricavare uno score relativo all'entità del beneficio clinico ottenuto per ciascun RCT. Sono state calcolate inoltre le differenze in termini di PFS tra i diversi bracci di trattamento rapportandole con i costi dei farmaci necessari per ottenere il beneficio di PFS. La nostra analisi ha valutato 11 RCT di fase III, per un totale di 4572 pazienti. Combinando i costi della terapia con la misura dell'efficacia espressa dalla PFS, è stato ottenuto un costo di 74,12 euro (€) per mese di vita guadagnato in termini di PFS con la combinazione di 5-fluorouracil, leucovorin, irinotecan e oxaliplatino (FOLFIRINOX), 90,14 € per la combinazione di gemcitabina e oxaliplatino (GEMOX) e 4708,7 € per la combinazione di nab-paclitaxel e gemcitabina. Da questo punto di vista riteniamo che l'utilizzo delle "vecche chemioterapie di combinazione" (per es., GEMOX) non dovrebbe essere completamente abbandonato, ma valutato sul singolo paziente, sulla base di diversi fattori (età, ECOG PS, comorbilità, carico di malattia), al fine di ottenere una reale "tailored therapy".

  14. [Comparative study of sleep patterns in nurses working day and night shifts].

    PubMed

    De Martino, Milva Maria Figueiredo

    2002-08-01

    To compare sleep patterns in nurses working day and night shifts in a hospital in Campinas (SP), Brazil. Fifty-nine nurses between 23 and 59 years of age participated in the study. For day shift workers, the pattern of nocturnal sleep was examined; for night shift workers, nocturnal and diurnal sleep patterns were examined. During 1 week, participants filled out a sleep diary right after waking up. The following items were assessed: time going to bed, falling asleep, and waking up; sleep latency; duration in hours of nocturnal and diurnal sleep; naps; quality of sleep; mode of waking up; and comparison between the sleep recorded in the diary with the usual sleep. Personal and professional information was also collected. Day shift workers went to bed at 23h36min, and night workers at 23h52min (P > 0.05). The nurses working a day schedule woke up earlier (7h3min) than those working a night schedule when they slept at night (8h30min) (P sono de enfermeiros dos turnos diurno e noturno em um hospital de Campinas (SP

  15. [Population health surveillance of the general population living near Turin (Northern Italy) incinerator (SPoTT): methodology of the study].

    PubMed

    Bena, Antonella; Chiusolo, Monica; Orengia, Manuela; Cadum, Ennio; Farina, Elena; Musmeci, Loredana; Procopio, Enrico; Salamina, Giuseppe

    2016-01-01

    Si intende qui descrivere il sistema di sorveglianza sugli effetti sulla salute (SpoTT) dell'inquinamento ambientale nelle aree circostanti l'inceneritore di Torino. SPoTT ha 3 linee di attività: 1. monitoraggio epidemiologico degli effetti a breve termine attraverso analisi temporali e misura della correlazione tra livelli giornalieri di emissioni dell'impianto e andamento degli eventi individuati dagli archivi dei dimessi (SDO), di pronto soccorso e di mortalità; sono coinvolti coloro che nel 2013-2018 risiedevano nell'area di ricaduta delle emissioni; 2. sorveglianza epidemiologica degli effetti a lungo termine, stimando tassi standardizzati di mortalità e morbosità; a ogni soggetto è attribuito il valore stimato di esposizione cumulato nel tempo caratteristico della residenza anagrafica; le informazioni sulla salute sono reperite dagli archivi SDO, di mortalità e dai certificati di assistenza al parto; sono studiati due decenni pre-post l'avvio dell'impianto: 2003-2012 e 2013-2022; 3. monitoraggio biologico con misurazione pre-post di metalli, PCDD/F, PCB, OH-IPA; sono coinvolti 196 residenti esposti e 196 di controllo di 35-69 anni, campionati a caso dalle anagrafi comunali; sono effettuate misure di funzionalità endocrina e respiratoria, pressione arteriosa, rischio cardiovascolare; l'esposizione cumulativa sarà stimata per ciascuna persona campionata integrando l'indirizzo di residenza, il tempo di permanenza in ciascun indirizzo e i dati ricavati dai modelli di ricaduta; sarà costituita una biobanca per future indagini di laboratorio; sono coinvolti anche 20 allevatori e i lavoratori dell'impianto. Una quarta linea di attività, non descritta in questo articolo, riguarda il monitoraggio della salute dei lavoratori addetti all'impianto. SPoTT è il primo studio in Italia su inceneritori e salute che adotta un disegno di studio longitudinale di adeguata potenza sia per i residenti sia per i lavoratori. I primi risultati sono attesi nel corso del 2016.

  16. Non-Volatile High Speed & Low Power Charge Trapping Devices

    NASA Astrophysics Data System (ADS)

    Kim, Moon Kyung; Tiwari, Sandip

    2007-06-01

    We report the operational characteristics of ultra-small-scaled SONOS (below 50 nm gate width and length) and SiO2/SiO2 structural devices with 0.5 um gate width and length where trapping occurs in a very narrow region. The experimental work summarizes the memory characteristics of retention time, endurance cycles, and speed in SONOS and SiO2/SiO2 structures. Silicon nitride has many defects to hold electrons as charge storage media in SONOS memory. Defects are also incorporated during growth and deposition in device processing. Our experiments show that the interface between two oxides, one grown and one deposited, provides a remarkable media for electron storage with a smaller gate stack and thus lower operating voltage. The exponential dependence of the time on the voltage is reflected in the characteristic energy. It is ˜0.44 eV for the write process and ˜0.47 eV for the erase process in SiO2/SiO2 structural device which is somewhat more efficient than those of SONOS structure memory.

  17. Enhanced sonochemical degradation of azure B dye by the electroFenton process.

    PubMed

    Martínez, Susana Silva; Uribe, Edgar Velasco

    2012-01-01

    The degradation of azure B dye (C15H16ClN3S; AB) has been studied by Fenton, sonolysis and sono-electroFenton processes employing ultrasound at 23 kHz and the electrogeneration of H2O2 at the reticulated vitreous carbon electrode. It was found that the dye degradation followed apparent first-order kinetics in all the degradation processes tested. The rate constant was affected by both the pH of the solution and initial concentration of Fe2+, with the highest degradation obtained at pH between 2.6 and 3. The first-order rate constant decreased in the following order: sono-electroFenton>Fenton>sonolysis. The rate constant for AB degradation by sono-electroFenton is ∼10-fold that of sonolysis and ∼2-fold the one obtained by Fenton under silent conditions. The chemical oxygen demand was abated ∼68% and ∼85% by Fenton and sono-electroFenton respectively, achieving AB concentration removal over 90% with both processes. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Intraoperative Ultrasound to Assess for Pancreatic Duct Injuries

    DTIC Science & Technology

    2015-04-01

    cholecystocholangiopancreatography is often nondiagnostic, gastroenterologists may not be available for endoscopic retrograde cholangiopancreatography (ERCP...10MHz.We use the SonoSite MicroMaxx SLT 10-5 MHz 52mm broadband linear array intraoperative US probe ( FUJIFILM SonoSite, Inc., Bothell, WA). The duct...Intraoperative US Availability Is gastroenterology available? Is the fluoroscopic and endoscopic equipment available? Is MRCP available? Is a

  19. Acoustic Characterization and Enhanced Ultrasound Imaging of Long-Circulating Lipid-Coated Microbubbles.

    PubMed

    Li, Hongbo; Yang, Yanye; Zhang, Meimei; Yin, Liping; Tu, Juan; Guo, Xiasheng; Zhang, Dong

    2018-05-01

    A long-circulating lipid-coated ultrasound (US) contrast agent was fabricated to achieve a longer wash-out time and gain more resistance against higher-mechanical index sonication. Systemic physical, acoustic, and in vivo imaging experiments were performed to better understand the underlying mechanism enabling the improvement of contrast agent performance by adjusting the physical and acoustic properties of contrast agent microbubbles. By simply altering the gas core, a kind of US contrast agent microbubble was synthesized with a similar lipid-coating shell as SonoVue microbubbles (Bracco SpA, Milan, Italy) to achieve a longer wash-out time and higher inertial cavitation threshold. To bridge the structure-performance relationship of the synthesized microbubbles, the imaging performance of the microbubbles was assessed in vivo with SonoVue as a control group. The size distribution and inertial cavitation threshold of the synthesized microbubbles were characterized, and the shell parameters of the microbubbles were determined by acoustic attenuation measurements. All of the measurements were compared with SonoVue microbubbles. The synthesized microbubbles had a spherical shape, a smooth, consistent membrane, and a uniform distribution, with an average diameter of 1.484 μm. According to the measured attenuation curve, the synthesized microbubbles resonated at around 2.8 MHz. Although the bubble's shell elasticity (0.2 ± 0.09 N/m) was comparable with SonoVue, it had relatively greater viscosity and inertial cavitation because of the different gas core. Imaging studies showed that the synthesized microbubbles had a longer circulation time and a better chance of fighting against rapid collapse than SonoVue. Nano/micrometer long-circulating lipid-coated microbubbles could be fabricated by simply altering the core composition of SonoVue microbubbles with a higher-molecular weight gas. The smaller diameter and higher inertial cavitation threshold of the

  20. A FPGA-based Measurement System for Nonvolatile Semiconductor Memory Characterization

    NASA Astrophysics Data System (ADS)

    Bu, Jiankang; White, Marvin

    2002-03-01

    Low voltage, long retention, high density SONOS nonvolatile semiconductor memory (NVSM) devices are ideally suited for PCMCIA, FLASH and 'smart' cards. The SONOS memory transistor requires characterization with an accurate, rapid measurement system with minimum disturbance to the device. The FPGA-based measurement system includes three parts: 1) a pattern generator implemented with XILINX FPGAs and corresponding software, 2) a high-speed, constant-current, threshold voltage detection circuit, 3) and a data evaluation program, implemented with a LABVIEW program. Fig. 1 shows the general block diagram of the FPGA-based measurement system. The function generator is designed and simulated with XILINX Foundation Software. Under the control of the specific erase/write/read pulses, the analog detect circuit applies operational modes to the SONOS device under test (DUT) and determines the change of the memory-state of the SONOS nonvolatile memory transistor. The TEK460 digitizes the analog threshold voltage output and sends to the PC computer. The data is filtered and averaged with a LABVIEWTM program running on the PC computer and displayed on the monitor in real time. We have implemented the pattern generator with XILINX FPGAs. Fig. 2 shows the block diagram of the pattern generator. We realized the logic control by a method of state machine design. Fig. 3 shows a small part of the state machine. The flexibility of the FPGAs enhances the capabilities of this system and allows measurement variations without hardware changes. The characterization of the nonvolatile memory transistor device under test (DUT), as function of programming voltage and time, is achieved by a high-speed, constant-current threshold voltage detection circuit. The analog detection circuit incorporating fast analog switches controlled digitally with the FPGAs. The schematic circuit diagram is shown in Fig. 4. The various operational modes for the DUT are realized with control signals applied to the

  1. Low Power Resistive Oxygen Sensor Based on Sonochemical SrTi0.6Fe0.4O2.8 (STFO40)

    PubMed Central

    Stratulat, Alisa; Serban, Bogdan-Catalin; de Luca, Andrea; Avramescu, Viorel; Cobianu, Cornel; Brezeanu, Mihai; Buiu, Octavian; Diamandescu, Lucian; Feder, Marcel; Ali, Syed Zeeshan; Udrea, Florin

    2015-01-01

    The current paper reports on a sonochemical synthesis method for manufacturing nanostructured (typical grain size of 50 nm) SrTi0.6Fe0.4O2.8 (Sono-STFO40) powder. This powder is characterized using X ray-diffraction (XRD), Mössbauer spectroscopy and Scanning Electron Microscopy (SEM), and results are compared with commercially available SrTi0.4Fe0.6O2.8 (STFO60) powder. In order to manufacture resistive oxygen sensors, both Sono-STFO40 and STFO60 are deposited, by dip-pen nanolithography (DPN) method, on an SOI (Silicon-on-Insulator) micro-hotplate, employing a tungsten heater embedded within a dielectric membrane. Oxygen detection tests are performed in both dry (RH = 0%) and humid (RH = 60%) nitrogen atmosphere, varying oxygen concentrations between 1% and 16% (v/v), at a constant heater temperature of 650 °C. The oxygen sensor, based on the Sono-STFO40 sensing layer, shows good sensitivity, low power consumption (80 mW), and short response time (25 s). These performance are comparable to those exhibited by state-of-the-art O2 sensors based on STFO60, thus proving Sono-STFO40 to be a material suitable for oxygen detection in harsh environments. PMID:26205267

  2. Sono-thermal oxidation of dihydropyrimidinones.

    PubMed

    Memarian, Hamid Reza; Farhadi, Asadollah

    2008-09-01

    Combination of ultrasound and heat has been used for the oxidation of some ethyl 3,4-dihydropyrimidin-2(1H)-one-5-carboxylates to their corresponding ethyl pyrimidin-2(1H)-one-5-carboxylates by using potassium peroxydisulfate in aqueous acetonitrile. An ultrasonic probe of 24 kHz frequency has been used for this study. Whereas the use of ultrasound increases the rate of reactions compared with reactions at reflux conditions, the nature of 4-substituent on the dihydropyrimidinone ring affects also the rate of reaction.

  3. Colour Doppler and microbubble contrast agent ultrasonography do not improve cancer detection rate in transrectal systematic prostate biopsy sampling.

    PubMed

    Taverna, Gianluigi; Morandi, Giovanni; Seveso, Mauro; Giusti, Guido; Benetti, Alessio; Colombo, Piergiuseppe; Minuti, Francesco; Grizzi, Fabio; Graziotti, Pierpaolo

    2011-12-01

    What's known on the subject? and What does the study add? Transrectal gray-scale ultrasonography guided prostate biopsy sampling is the method for diagnosing prostate cancer (PC) in patients with an increased prostate specific antigen level and/or abnormal digital rectal examination. Several imaging strategies have been proposed to optimize the diagnostic value of biopsy sampling, although at the first biopsy nearly 10-30% of PC still remains undiagnosed. This study compares the PC detection rate when employing Colour Doppler ultransongraphy with or without the injection of SonoVue™ microbubble contrast agent, versus the transrectal ultrasongraphy-guided systematic biopsy sampling. The limited accuracy, sensitivity, specificity and the additional cost of using the contrast agent do not justify its routine application in PC detection. • To compare prostate cancer (PC) detection rate employing colour Doppler ultrasonography with or without SonoVue™ contrast agent with transrectal ultrasonography-guided systematic biopsy sampling. • A total of 300 patients with negative digital rectal examination and transrectal grey-scale ultrasonography, with PSA values ranging between 2.5 and 9.9 ng/mL, were randomized into three groups: 100 patients (group A) underwent transrectal ultrasonography-guided systematic bioptic sampling; 100 patients (group B) underwent colour Doppler ultrasonography, and 100 patients (group C) underwent colour Doppler ultrasonography before and during the injection of SonoVue™. • Contrast-enhanced targeted biopsies were sampled into hypervascularized areas of peripheral, transitional, apical or anterior prostate zones. • All the patients included in Groups B and C underwent a further 13 systematic prostate biopsies. The cancer detection rate was calculated for each group. • In 88 (29.3%) patients a histological diagnosis of PC was made, whereas 22 (7.4%) patients were diagnosed with high-grade prostatic intraepithelial

  4. Use of a decision-analytic model to support the use of a new oral US contrast agent in patients with abdominal pain.

    PubMed

    Bree, R L; Arnold, R J; Pettit, K G; Kaniecki, D J; O'haeri, C; LaFrance, N D; Toaff, A L

    2001-03-01

    The authors performed this study to compare the cost and diagnostic abilities of ultrasound (US) performed with and without the use of an oral contrast material recently approved by the U.S. Food and Drug Administration. An interactive decision-analytic model was constructed to compare US performed with and without contrast material (SonoRx; Bracco Diagnostics) for the evaluation of patients with abdominal pain who were suspected of having pancreatic disease. The model considered all resources that might be used to evaluate a patient suspected of having pancreatic disease (eg, US, computed tomography [CT], endoscopic retrograde cholangiopancreatography, fine-needle aspiration biopsy, and open biopsy). The literature and an expert panel were the clinical data sources. Cost estimates were based on Medicare and non-Medicare reimbursements. The primary cost-effectiveness measure was the cost to achieve a diagnosis. SonoRx-enhanced US was less expensive than unenhanced US ($714 vs $808, respectively, with Medicare costs; $1,612 vs $1,878, respectively, with non-Medicare costs) and as effective (0.785 vs 0.782, respectively). SonoRx-enhanced US was more cost-effective than unenhanced US ($909 vs $1,034, respectively, with Medicare costs; $2,052 vs $2,401, respectively, with non-Medicare costs). This relationship was maintained throughout extensive sensitivity analyses. SonoRx-enhanced US is more cost-effective than unenhanced US, primarily because it avoids the need for CT. CT may be avoided owing to the higher probability of obtaining optimal US scans with oral contrast material.

  5. Needle echogenicity in ultrasound-guided lumbar spine injections: a cadaveric study.

    PubMed

    Gofeld, Michael; Krashin, Daniel L; Ahn, Sangmin

    2013-01-01

    Echogenicity of regional anesthesia needles has been tested on different preclinical models; however, previous studies were done in an ideal experimental setting utilizing high-frequency insonation and superficially located targets. Because steep-angle deep injections are typically required for spinal and other chronic pain procedures, and low-frequency transducers are used, further feasibility study is warranted. To determine effectiveness of steep-angle deep injections, typically required for spinal and other chronic pain procedures. Experimental laboratory study. Willed Body Program, University of Washington. In-plane lumbar spine procedures with 50° and 70° angles were performed on a human cadaver. The images and video clips of a non-echogenic (Quincke-type) and echogenic (SonoPlex, StimuQuick, and EchoStim) needle placements were presented to 3 blinded assessors who rated the needle visibility on a 4-point scale. The data was statistically analyzed to determine the differences in visibility between the needles with and without the digital image enhancement, and to compare the video clips to captured images. ANOVA analysis demonstrated that overall SonoPlex was significantly better (P = 0.02) than other needles. SonoPlex maintained its superiority in the subset of facet joint injections (P = 0.02), followed by Quincke-type, then the StimuQuik, and EchoStim needles. In deep procedures, EchoStim was comparable with SonoPlex (P = 0.03), and they both were better than the other 2 needles. The enhanced images received higher rates, with a 0.6 point mean improved rating (P = 0). This study is limited by choice of needles, number of experiments performed, and potential postmortem changes of echogenicity. The SonoPlex needle appeared to have better echogenicity in this study. While non-echogenic Quincke-type needle visibility was adequate in superficial placements, it was limited in deep injections. An imaging enhancement is effective in improving needle visibility

  6. Il ruolo svolto dall’attività lavorativa sull’ipertensione arteriosa

    PubMed Central

    Barbini, N.; Gorini, G.; Ferrucci, L.; Biggeri, A.

    2009-01-01

    RIASSUNTO Introduzione I parametri di pressione arteriosa, sistolica (PAS) o diastolica (PAD) hanno costituito I’oggetto di numerosi studi, alcuni dei quali stabiliscono un’associazione tra I’aumnto di tali parametri e la mortalità, in particolare alle età medie. I fattori di rischio di ipertensione più frequentemente studiati sono il consumo di alcol, il fumo e I’origine etnica in riferimento sia alle differenze genetiche che nella condotta alimentare, mentre i fattori di origine professionale sono stati presi in considerazione più raramente e in maniera poco approfondita, inoltre sono state riferite notevoli differenze nelle pressioni arteriose medie di individui che svolgono professioni diverse. Sembra infatti che i “colletti blu” siano più a rischio dei “colletti bianchi”. Obiettivi Il nostro scopo è valutare se determinati rischi o vincoli connessi con l’attività professionale o determinati stili di vita rappresentano un fattore di rischio per l’ipertensione arteriosa in considerazioni dell’aumentare dell’età. Elementi specifici che rendano conto di questa relazione non sono stati ancora completamente chiariti e soprattutto i dati sulla popolazione italiana sono molto limitati. Metodi La metodologia di ricerca utilizzata è stata quella dell’indagine francese ESTEV (Derriennic, Touranchet, Volkoff) - VISAT (Marquie, Janson), studio epidemiologico longitudinale su oltre 23000 lavoratori attivata in Francia nel 1990 al fine di indagare gli effetti a lungo termine delle condizioni di lavoro, riferite all’intera vita professionale, sia sull’invecchiamento sia sulla salute dei lavoratori. Analoga indagine è stata avviata in Italia, nel 2000, in 6 Regioni, prendendo in esame i lavoratori dipendenti di diversi settori produttivi appartenenti a 5 coorti di età: da 32 a 52 anni con intervallo di 5 anni. Le rilevazioni sono state effettuate dai medici del lavoro di azienda attraverso 3 questionari: 1. sulle condizioni

  7. [National epidemiological surveillance systems of mesothelioma cases].

    PubMed

    Ferrante, Pierpaolo; Binazzi, Alessandra; Branchi, Claudia; Marinaccio, Alessandro

    2016-01-01

    INTRODUZIONE: sebbene la relazione causale tra esposizione ad amianto e malattie neoplastiche sia ben nota, in molti Paesi il consumo del materiale è ancora rilevante e crescente. A causa della lunga latenza, nei Paesi dove è stato bandito (come in Italia) è oggi in corso un'epidemia di malattie correlate ad amianto. OBIETTIVI: descrivere i sistemi di sorveglianza dei mesoteliomi attivi nel mondo mediante un'analisi comparativa. è stata condotta una revisione bibliografica della letteratura disponibile sui sistemi di sorveglianza epidemiologica dei mesoteliomi attivi nel mondo, comparando metodi e risultati disponibili. RISULTATI: sistemi di ricerca dei casi incidenti e di analisi anamnestica dei soggetti ammalati sono attivi solo in Italia, Francia e Corea del Sud. I Paesi presso i quali sono attivi sistemi di rilevazione e controllo dei casi incidenti di mesotelioma sono quelli in cui vige il bando dell'amianto e che hanno sperimentato consumi rilevanti in passato. Non sono stati istituiti sistemi epidemiologici di sorveglianza in molti Paesi dove il consumo di amianto è ancora importante (inclusi Russia, Cina, India e Brasile). CONCLUSIONI: si conferma l'importanza dei sistemi di sorveglianza epidemiologica dei mesoteliomi per la sanità pubblica, il sostegno alle politiche di welfare e la prevenzione dei rischi. Lo sviluppo di progetti per tendere a una maggiore uniformità nei metodi di ricerca dei casi, di classificazione delle diagnosi e dell'esposizione e nelle tecniche di analisi dei dati potrebbe consentire una maggiore fruibilità dei dati aggregati. La disponibilità di dati internazionali confrontabili può essere di stimolo all'adozione di provvedimenti di bando internazionale.

  8. Education in children's sleep hygiene: which approaches are effective? A systematic review.

    PubMed

    Halal, Camila S E; Nunes, Magda L

    2014-01-01

    To analyze the interventions aimed at the practice of sleep hygiene, as well as their applicability and effectiveness in the clinical scenario, so that they may be used by pediatricians and family physicians for parental advice. A search of the PubMed database was performed using the following descriptors: sleep hygiene OR sleep education AND children or school-aged. In the LILACS and SciELO databases, the descriptors in Portuguese were: higiene E sono, educação E sono, educação E sono E crianças, e higiene E sono E infância, with no limitations of the publication period. In total, ten articles were reviewed, in which the main objectives were to analyze the effectiveness of behavioral approaches and sleep hygiene techniques on children's sleep quality and parents' quality of life. The techniques used were one or more of the following: positive routines; controlled comforting and gradual extinction or sleep remodeling; as well as written diaries to monitor children's sleep patterns. All of the approaches yielded positive results. Although behavioral approaches to pediatric sleep hygiene are easy to apply and adhere to, there have been very few studies evaluating the effectiveness of the available techniques. This review demonstrated that these methods are effective in providing sleep hygiene for children, thus reflecting on parents' improved quality of life. It is of utmost importance that pediatricians and family physicians are aware of such methods in order to adequately advise patients and their families. Copyright © 2014 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  9. Sleep-disordered breathing in patients with COPD and mild hypoxemia: prevalence and predictive variables.

    PubMed

    Silva, José Laerte Rodrigues; Conde, Marcus Barreto; Corrêa, Krislainy de Sousa; Rabahi, Helena; Rocha, Arthur Alves; Rabahi, Marcelo Fouad

    2017-01-01

    To infer the prevalence and variables predictive of isolated nocturnal hypoxemia and obstructive sleep apnea (OSA) in patients with COPD and mild hypoxemia. This was a cross-sectional study involving clinically stable COPD outpatients with mild hypoxemia (oxygen saturation = 90-94%) at a clinical center specializing in respiratory diseases, located in the city of Goiânia, Brazil. The patients underwent clinical evaluation, spirometry, polysomnography, echocardiography, arterial blood gas analysis, six-minute walk test assessment, and chest X-ray. The sample included 64 patients with COPD and mild hypoxemia; 39 (61%) were diagnosed with sleep-disordered breathing (OSA, in 14; and isolated nocturnal hypoxemia, in 25). Correlation analysis showed that PaO2 correlated moderately with mean sleep oxygen saturation (r = 0.45; p = 0.0002), mean rapid eye movement (REM) sleep oxygen saturation (r = 0.43; p = 0.001), and mean non-REM sleep oxygen saturation (r = 0.42; p = 0.001). A cut-off point of PaO2 ≤ 70 mmHg in the arterial blood gas analysis was significantly associated with sleep-disordered breathing (OR = 4.59; 95% CI: 1.54-13.67; p = 0.01). The model showed that, for identifying sleep-disordered breathing, the cut-off point had a specificity of 73.9% (95% CI: 51.6-89.8%), a sensitivity of 63.4% (95% CI: 46.9-77.9%), a positive predictive value of 81.3% (95% CI: 67.7-90.0%), and a negative predictive value of 53.1% (95% CI: 41.4-64.4%), with an area under the ROC curve of 0.69 (95% CI: 0.57-0.80), correctly classifying the observations in 67.2% of the cases. In our sample of patients with COPD and mild hypoxemia, the prevalence of sleep-disordered breathing was high (61%), suggesting that such patients would benefit from sleep studies. Inferir a prevalência e as variáveis preditivas de hipoxemia noturna e apneia obstrutiva do sono (AOS) em pacientes portadores de DPOC com hipoxemia leve. Estudo transversal realizado em pacientes ambulatoriais, clinicamente est

  10. The use of contrasted transvaginal sonography in the diagnosis of gynecologic diseases: a preliminary study.

    PubMed

    Testa, Antonia Carla; Ferrandina, Gabriella; Fruscella, Erika; Van Holsbeke, Caroline; Ferrazzi, Enrico; Leone, Francesco P G; Arduini, Domenico; Exacoustos, Caterina; Bokor, Daniela; Scambia, Giovanni; Timmerman, Dirk

    2005-09-01

    The purpose of this study was to evaluate the efficacy of a new contrast-dedicated ultrasound technology, contrast-tuned imaging (CnTI), implemented on an endovaginal probe and using the second-generation contrast agent SonoVue (Bracco International BV, Amsterdam, the Netherlands), compared with the standard ultrasound examination in different gynecologic diseases. Eighty-nine patients were enrolled in the study in 4 different clinical centers. The study included 40 patients with uncertain pelvic adnexal masses, 10 patients with pelvic masses indicative of recurrences of gynecologic tumors, 26 patients with uterine pathologic features, and 13 patients with cervical lesions. Application of CnTI technology after the SonoVue injection gave a picture of the intralesional microvascularization dramatically different from that obtained during color Doppler examination. Of the 40 pelvic masses, 15 (37.5%) were considered benign and 25 (62.5%) were considered malignant at B-mode and color Doppler examinations. Contrast-enhanced sonography showed no intralesional contrast perfusion in 11 (73%) of 15 cases, and all these were benign at final diagnosis. Of the 4 (27%) cases that had perfusion, 2 were malignant. Conversely, of the 25 cases with positive findings at color Doppler examination and therefore expected to show the appearance of contrast tissue-filling morphologic characteristics, 13 (52%) were malignant at final diagnosis. For evaluation of uterine pathologic features, the CnTI-SonoVue technology did not appear to be superior to the B-mode and color Doppler examinations; however, for the evaluation of cervical cancer, CnTI-SonoVue technology revealed a better definition of the margins of the neoplastic lesions in 4 (40%) of 10 cases. In the evaluation of uncertain pelvic masses, the CnTI technology led to an improvement in the ability of the practitioner to differentiate benign from malignant adnexal lesions.

  11. Influence of temperature, needle gauge and injection rate on the size distribution, concentration and acoustic responses of ultrasound contrast agents at high frequency.

    PubMed

    Sun, Chao; Panagakou, Ioanna; Sboros, Vassilis; Butler, Mairead B; Kenwright, David; Thomson, Adrian J W; Moran, Carmel M

    2016-08-01

    This paper investigated the influence of needle gauge (19G and 27G), injection rate (0.85ml·min(-1), 3ml·min(-1)) and temperature (room temperature (RT) and body temperature (BT)) on the mean diameter, concentration, acoustic attenuation, contrast to tissue ratio (CTR) and normalised subharmonic intensity (NSI) of three ultrasound contrast agents (UCAs): Definity, SonoVue and MicroMarker (untargeted). A broadband substitution technique was used to acquire the acoustic properties over the frequency range 17-31MHz with a preclinical ultrasound scanner Vevo770 (Visualsonics, Canada). Significant differences (P<0.001-P<0.05) between typical in vitro setting (19G needle, 3ml·min(-1) at RT) and typical in vivo setting (27G needle, 0.85ml·min(-1) at BT) were found for SonoVue and MicroMarker. Moreover we found that the mean volume-based diameter and concentration of both SonoVue and Definity reduced significantly when changing from typical in vitro to in vivo experimental set-ups, while those for MicroMarker did not significantly change. From our limited measurements of Definity, we found no significant change in attenuation, CTR and NSI with needle gauge. For SonoVue, all the measured acoustic properties (attenuation, CTR and NSI) reduced significantly when changing from typical in vitro to in vivo experimental conditions, while for MicroMarker, only the NSI reduced, with attenuation and CTR increasing significantly. These differences suggest that changes in physical compression and temperature are likely to alter the shell structure of the UCAs resulting in measureable and significant changes in the physical and high frequency acoustical properties of the contrast agents under typical in vitro and preclinical in vivo experimental conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. [Trattamento della dipendenza da alcol. Alcol e persone senza fissa dimora: punto di vista sociale].

    PubMed

    Alessandrini, Giovanni; Ciccarelli, Rosaria; Battagliese, Gemma; Cereatti, Federica; Gencarelli, Simona; Messina, Marisa Patrizia; Vitali, Mario; De Rosa, Francesca; Ledda, Roberta; Mancini, Serena; Attilia, Maria Luisa

    2018-01-01

    RIASSUNTO. Il fenomeno delle persone senza fissa dimora sta assumendo in questi anni una rilevanza sociale devastante, con una prevalenza stimata in USA e in Europa compresa tra il 5,6% e il 13,9%. Queste persone hanno una scarsa qualità di vita, una limitata o assente vita sociale, sono spesso disoccupate o lavorano solo saltuariamente. Sono a rischio di problemi con la legge, sono spesso affette da dipendenza da droghe, da patologie psichiatriche e internistiche. L'alcol spesso non rappresenta la causa della loro condizione sociale, ma solo la conseguenza, contribuendo in questo modo al loro degrado bio-psico-sociale. Nel 2009 lo US Department of Housing and Urban Development's Homelessness Assistance Programs e nel 2010 la European Consensus Conference on Homelessness hanno segnato un grande passo avanti nella riabilitazione sociale di queste persone, utilizzando il concetto del "case management". In particolare lo Standard Case Management si è dimostrato in grado di migliorare la stabilità abitativa, di ridurre l'uso di droghe e di rimuovere le barriere lavorative. L'Assertive Community Treatment si è dimostrato, invece, in grado di migliorare la stabilità abitativa e ha un rapporto costo/beneficio migliore per i pazienti affetti da doppia diagnosi.

  13. [Analysis of factors predicting early unplanned readmissions].

    PubMed

    Di Domenico, Gabriella; Tersigni, Ivan; Federico, Bruno; Leuter, Cinzia

    2016-01-01

    OBIETTIVI: determinare i fattori associati ai ricoveri ripetuti per identificare i pazienti a rischio di riospedalizzazione entro i 30 giorni dalla dimissione. DISEGNO: analisi retrospettiva delle dimissioni nell'anno 2013 attraverso le schede di dimissione ospedaliera (SDO). 3.900 pazienti ricoverati presso il presidio ospedaliero "Fabrizio Spaziani" di Frosinone. PRINCIPALI MISURE DI OUTCOME: analisi bivariata per l'analisi dell'associazione tra variabili. La regressione logistica è stata utilizzata per identificare i fattori di rischio associati al ricovero ripetuto. RISULTATI: tra i 3.900 pazienti considerati, il 12,8% ha avuto una riammissione non programmata entro un mese dalla dimissione precedente per le stesse categorie diagnostiche principali (MCD). Sono state rilevate differenze statisticamente significative tra i pazienti con e senza ricovero ripetuto per età, durata della degenza, titolo di studio, condizione occupazionale e diagnosi. I fattori che aumentano la probabilità di una riospedalizzazione sono il vivere da solo, la condizione di pensionato o casalinga, una degenza più lunga e alcune diagnosi, fra cui malattie dell'apparato respiratorio, del sistema nervoso e dell'apparato urinario. CONCLUSIONE: alcune caratteristiche sociodemografiche e la diagnosi dei pazienti ospedalizzati sono associate al rischio di riospedalizzazione entro 30 giorni dalla dimissione. I dati disponibili nell'archivio delle SDO possono essere utilizzati per un'identificazione dei pazienti a rischio sui quali definire specifici piani di dimissione.

  14. Ultrasound active nanoscaled lipid formulations for thrombus lysis.

    PubMed

    Becker, Andreas; Marxer, Elena; Brüssler, Jana; Hoormann, Anne Sophia; Kuhnt, Daniela; Bakowsky, Udo; Nimsky, Christopher

    2011-04-01

    In the present study, we investigated the sonothrombolytic effect of new nanoscaled lipid formulations in human blood clots, using diagnostic ultrasound. Human blood clots of 1 ml were incubated with 1 μl of the different lipid dispersions DPPC/CH, DPPC/PEG40S, DSPC/PEG40S and the commercially available ultrasound contrast agent SonoVue®. Clots were stored for 3 days at 5 °C to obtain maximal clot retraction and lytic resistance. Each clot weight was determined before and after continuous insonation for 1h of insonation at 1.4 MHz. The pressure in the insonation chamber was 80 mm Hg to mimic middle arterial blood pressure. There were no significant differences in thrombus weight before insonation. All nanoscaled formulations and SonoVue® were able to reduce thrombus weight compared to the weight loss of clots that were not insonated but kept under pressure for one hour (p < 0.001). We found a highly significant weight reduction with DSPC/PEG40S compared to SonoVue® (p = 0.007). Nanoscaled DSPC/PEG40S dispersion could be a promising formulation in ultrasound enhanced thrombolysis even without thrombolytic drugs. Stable cavitation is a crucial parameter in fragmentation of thrombus architecture. Further studies of physicochemical properties of DSPC/PEG40S are necessary to corroborate our hypothesis. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Technical and social evaluation of arsenic mitigation in rural Bangladesh.

    PubMed

    Shafiquzzaman, Md; Azam, Md Shafiul; Mishima, Iori; Nakajima, Jun

    2009-10-01

    Technical and social performances of an arsenic-removal technology--the sono arsenic filter--in rural areas of Bangladesh were investigated. Results of arsenic field-test showed that filtered water met the Bangladesh standard (< 50 microg/L) after two years of continuous use. A questionnaire was administrated among 198 sono arsenic filter-user and 230 non-user families. Seventy-two percent of filters (n = 198) were working at the time of the survey. Another 28% of the filters were abandoned due to breakage. The abandonment percentage (28%) was lower than other mitigation options currently implemented in Bangladesh. Households were reluctant to repair the broken filters on their own. High cost, problems with maintenance of filters, weak sludge-disposal guidance, and slow flow rate were the other demerits of the filter. These results indicate that the implementation approaches of the sono arsenic filter suffered from lack of ownership and long-term sustainability. Continuous use of arsenic-contaminated tubewells by the non-user households demonstrated the lack of alternative water supply in the survey area. Willingness of households to pay (about 30%) and preference of household filter (50%) suggest the need to develop a low-cost household arsenic filter. Development of community-based organization would be also necessary to implement a long-term, sustainable plan for household-based technology.

  16. Engineering design and prototype development of a full scale ultrasound system for virgin olive oil by means of numerical and experimental analysis.

    PubMed

    Clodoveo, Maria Lisa; Moramarco, Vito; Paduano, Antonello; Sacchi, Raffaele; Di Palmo, Tiziana; Crupi, Pasquale; Corbo, Filomena; Pesce, Vito; Distaso, Elia; Tamburrano, Paolo; Amirante, Riccardo

    2017-07-01

    The aim of the virgin olive oil extraction process is mainly to obtain the best quality oil from fruits, by only applying mechanical actions while guaranteeing the highest overall efficiency. Currently, the mechanical methods used to extract virgin oils from olives are basically of two types: the discontinuous system (obsolete) and the continuous one. Anyway the system defined as "continuous" is composed of several steps which are not all completely continuous, due to the presence of the malaxer, a device that works in batch. The aim of the paper was to design, realize and test the first full scale sono-exchanger for the virgin olive oil industry, to be placed immediately after the crusher and before the malaxer. The innovative device is mainly composed of a triple concentric pipe heat exchanger combined with three ultrasound probes. This mechanical solution allows both the cell walls (which release the oil droplets) along with the minor compounds to be destroyed more effectively and the heat exchange between the olive paste and the process water to be accelerated. This strategy represents the first step towards the transformation of the malaxing step from a batch operation into a real continuous process, thus improving the working capacity of the industrial plants. Considering the heterogeneity of the olive paste, which is composed of different tissues, the design of the sono-exchanger required a thorough fluid dynamic analysis. The thermal effects of the sono-exchanger were monitored by measuring the temperature of the product at the inlet and the outlet of the device; in addition, the measurement of the pigments concentration in the product allowed monitoring the mechanical effects of the sono-exchanger. The effects of the innovative process were also evaluated in terms of extra virgin olive oil yields and quality, evaluating the main legal parameters, the polyphenol and tocopherol content. Moreover, the activity of the polyphenol oxidase enzyme in the olive

  17. Work zone intrusion alarm effectiveness.

    DOT National Transportation Integrated Search

    2010-09-01

    16. Abstract : The New Jersey Department of Transportation (NJDOT) commissioned a study to evaluate how : effective a work zone safety device known as the SonoBlaster! Work Zone Intrusion Alarm would be : in protecting maintenance workers fro...

  18. DFT studies on the multi-channel reaction of CH3S+NO2

    NASA Astrophysics Data System (ADS)

    Tang, Yi-Zhen; Sun, Hao; Pan, Ya-Ru; Pan, Xiu-Mei; Wang, Rong-Shun

    The mechanisms for the reaction of CH3S with NO2 are investigated at the QCISD(T)/6-311++G(d,p)//B3LYP/6-311++G(d,p) on both single and triple potential energy surfaces (PESs). The geometries, vibrational frequencies, and zero-point energy (ZPE) correction of all stationary points involved in the title reaction are calculated at the B3LYP/6-311++G(d,p) level. More accurate energies are obtained at the QCISD(T)/6-311++G(d,p). The results show that 5 intermediates and 14 transition states are found. The reaction is more predominant on the single PES, while it is negligible on the triple PES. Without any barrier height for the whole process, the main channel of the reaction is to form CH3SONO and then dissociate to CH3SO+NO.

  19. [Ecological study on the mortality of residents in Manfredonia (Apulia Region, Southern Italy) from 1970 to 2013].

    PubMed

    Gianicolo, Emilio Antonio Luca; Mangia, Cristina; Cervino, Marco; Bruni, Antonella; De Marchi, Bruna; Biggeri, Annibale; Porcu, Rosa; Vigotti, Maria Angela

    2016-01-01

    OBIETTIVI: valutare lo stato di salute della popolazione residente nel comune di Manfredonia dal 1970 al 2013. DISEGNO: analisi descrittiva dell'andamento temporale della mortalità generale, per gruppi di cause, dal 1970 al 2013. SETTING E PARTECIPANTI: i dati di mortalità e le popolazioni residenti sono di fonte Istat. Sono state esaminate 55 cause di decesso. Le analisi sono disaggregate per sesso e periodo. PRINCIPALI MISURE DI OUTCOME: sono stati elaborati i rapporti standardizzati di mortalità (SMR%), con i rispettivi intervalli di confidenza al 90% (IC90%), e i tassi di mortalità standardizzati col metodo diretto (TSD ). RISULTATI: lo stato di salute misurato dal tasso di mortalità per tutte le cause migliora nel tempo: i TSD passano da 92 x10.000 negli anni 1970-1974 a 52 x10.000 nel biennio 2012-2013 negli uomini, da 70 x10.000 a 39 x10.000 nelle donne. Tuttavia, rispetto alla media regionale Manfredonia perde progressivamente il suo vantaggio, passando da -20% a -10% negli uomini, e da -20% a +1,5% nelle donne. Questo andamento è molto evidente per il complesso delle cause cardiovascolari, mentre i tumori maligni sono in generale nella media regionale. Nell'ultimo periodo disponibile per causa di decesso (2006-2011), la mortalità per infarto miocardico è stata più alta della media regionale (uomini: +35%; donne: +54%). I rapporti standardizzati di mortalità (SMR) mostrano tra gli uomini valori in crescita, in particolar modo rispetto al riferimento provinciale, con un eccesso a cominciare dal periodo 2006-2011 (22 decessi/anno e 19 attesi; SMR%: 117,2; IC90% 101,1-135,2; riferimento: provincia di Foggia). Anche tra le donne gli SMR% superano i riferimenti provinciali negli ultimi periodi esaminati (nel 2012-2013: 7 decessi/ anno e 4,2 attesi; SMR%: 116,4; IC90% 97,0-260,7; riferimento: provincia di Foggia). CONCLUSIONI: la mortalità a Manfredonia è diminuita in misura minore rispetto a quella osservata nei riferimenti provinciali e regionali

  20. Real-time sono-photoacoustic imaging of gold nanoemulsions

    NASA Astrophysics Data System (ADS)

    Arnal, Bastien; Wei, Chen-Wei; Perez, Camilo; Lombardo, Michael; Pelivanov, Ivan M.; Pozzo, Danilo; O'Donnell, Matthew

    2015-03-01

    Phase transition contrast agents were first introduced in ultrasound (US) in the form of perfluorocarbon droplets. When their size is reduced to the nanoscale, surface tension dominates their stability and high pressure is required to vaporize them using long US emissions at high frequencies. Our group recently showed that nanoemulsion beads (100-300 nm) coated with gold nanopsheres could be used as non-linear contrast agents. Beads can be vaporized with light only, inducing stronger photoacoustic signals by increasing thermal expansion. A photoacoustic cavitation threshold study (US: 1.2 MHz, Laser 750 nm and 10-ns pulse) shows that the vaporization thresholds of NEB-GNS can be greatly reduced using simultaneous light and US excitations. The resulting signal is driven only by the pressure amplitude for a fluence higher than 2.4 mJ/cm2. At diagnostic exposures, it is possible to capture very high signals from the vaporized beads at concentrations reduced to 10 pM with optical absorption smaller than 0.01 cm-1. A real-time imaging mode selectively isolating vaporization signals was implemented on a Verasonics system. A linear US probe (L74, 3 MHz) launched short US bursts before light was emitted from the laser. Vaporization of NEB-GNS resulted in a persistent 30-dB signal enhancement compared to a dye with the same absorption. Specific vaporization signals were retrieved in phantom experiments with US scatterers. This technique, called sonophotoacoustics, has great potential for targeted molecular imaging and therapy using compact nanoprobes with potentially high-penetrability into tissue.

  1. The Role of Ultrasound on Advanced Oxidation Processes.

    PubMed

    Babu, Sundaram Ganesh; Ashokkumar, Muthupandian; Neppolian, Bernaurdshaw

    2016-10-01

    This chapter describes the use of ultrasound in remediation of wastewater contaminated with organic pollutants in the absence and presence of other advanced oxidation processes (AOPs) such as sonolysis, sono-ozone process, sonophotocatalysis, sonoFenton systems and sonophoto-Fenton methods in detail. All these methods are explained with the suitable literature illustrations. In most of the cases, hybrid AOPs (combination of ultrasound with one or more AOPs) resulted in superior efficacy to that of individual AOP. The advantageous effects such as additive and synergistic effects obtained by operating the hybrid AOPs are highlighted with appropriate examples. It is worth to mention here that the utilization of ultrasound is not only restricted in preparation of modern active catalysts but also extensively used for the wastewater treatment. Interestingly, ultrasound coupled AOPs are operationally simple, efficient, and environmentally benign, and can be readily applied for large scale industrial processes which make them economically viable.

  2. Arsenic removal with composite iron matrix filters in Bangladesh: a field and laboratory study.

    PubMed

    Neumann, Anke; Kaegi, Ralf; Voegelin, Andreas; Hussam, Abul; Munir, Abul K M; Hug, Stephan J

    2013-05-07

    The main arsenic mitigation measures in Bangladesh, well-switching and deep tube wells, have reduced As exposure, but water treatment is important where As-free water is not available. Zero-valent iron (ZVI) based SONO household filters, developed in Bangladesh, remove As by corrosion of locally available inexpensive surplus iron and sand filtration in two buckets. We investigated As removal in SONO filters in the field and laboratory, covering a range of typical groundwater concentrations (in mg/L) of As (0.14-0.96), Fe (0-17), P (0-4.4), Ca (45-162), and Mn (0-2.8). Depending on influent Fe(II) concentrations, 20-80% As was removed in the top sand layer, but As removal to safe levels occurred in the ZVI-layer of the first bucket. Residual As, Fe, and Mn were removed after re-aeration in the sand of the second bucket. New and over 8-year-old filters removed As to <50 μg/L and mostly to <10 μg/L and Mn to <0.2 mg/L. Vertical concentration profiles revealed formation of Fe(II) by corrosion of Fe(0) with O2 and incorporation of As into forming amorphous Fe phases in the composite iron matrix (CIM) of newer filters and predominantly magnetite in older filters. As mass balances indicated that users filtered less than reported volumes of water, pointing to the need for more educational efforts. All tested SONO filters provided safe drinking water without replacement for up to over 8 years of use.

  3. Investigation on the inertial cavitation threshold and shell properties of commercialized ultrasound contrast agent microbubbles.

    PubMed

    Guo, Xiasheng; Li, Qian; Zhang, Zhe; Zhang, Dong; Tu, Juan

    2013-08-01

    The inertial cavitation (IC) activity of ultrasound contrast agents (UCAs) plays an important role in the development and improvement of ultrasound diagnostic and therapeutic applications. However, various diagnostic and therapeutic applications have different requirements for IC characteristics. Here through IC dose quantifications based on passive cavitation detection, IC thresholds were measured for two commercialized UCAs, albumin-shelled KangRun(®) and lipid-shelled SonoVue(®) microbubbles, at varied UCA volume concentrations (viz., 0.125 and 0.25 vol. %) and acoustic pulse lengths (viz., 5, 10, 20, 50, and 100 cycles). Shell elastic and viscous coefficients of UCAs were estimated by fitting measured acoustic attenuation spectra with Sarkar's model. The influences of sonication condition (viz., acoustic pulse length) and UCA shell properties on IC threshold were discussed based on numerical simulations. Both experimental measurements and numerical simulations indicate that IC thresholds of UCAs decrease with increasing UCA volume concentration and acoustic pulse length. The shell interfacial tension and dilatational viscosity estimated for SonoVue (0.7 ± 0.11 N/m, 6.5 ± 1.01 × 10(-8) kg/s) are smaller than those of KangRun (1.05 ± 0.18 N/m, 1.66 ± 0.38 × 10(-7) kg/s); this might result in lower IC threshold for SonoVue. The current results will be helpful for selecting and utilizing commercialized UCAs for specific clinical applications, while minimizing undesired IC-induced bioeffects.

  4. Estimation of intra-operator variability in perfusion parameter measurements using DCE-US.

    PubMed

    Gauthier, Marianne; Leguerney, Ingrid; Thalmensi, Jessie; Chebil, Mohamed; Parisot, Sarah; Peronneau, Pierre; Roche, Alain; Lassau, Nathalie

    2011-03-28

    To investigate intra-operator variability of semi-quantitative perfusion parameters using dynamic contrast-enhanced ultrasonography (DCE-US), following bolus injections of SonoVue(®). The in vitro experiments were conducted using three in-house sets up based on pumping a fluid through a phantom placed in a water tank. In the in vivo experiments, B16F10 melanoma cells were xenografted to five nude mice. Both in vitro and in vivo, images were acquired following bolus injections of the ultrasound contrast agent SonoVue(®) (Bracco, Milan, Italy) and using a Toshiba Aplio(®) ultrasound scanner connected to a 2.9-5.8 MHz linear transducer (PZT, PLT 604AT probe) (Toshiba, Japan) allowing harmonic imaging ("Vascular Recognition Imaging") involving linear raw data. A mathematical model based on the dye-dilution theory was developed by the Gustave Roussy Institute, Villejuif, France and used to evaluate seven perfusion parameters from time-intensity curves. Intra-operator variability analyses were based on determining perfusion parameter coefficients of variation (CV). In vitro, different volumes of SonoVue(®) were tested with the three phantoms: intra-operator variability was found to range from 2.33% to 23.72%. In vivo, experiments were performed on tumor tissues and perfusion parameters exhibited values ranging from 1.48% to 29.97%. In addition, the area under the curve (AUC) and the area under the wash-out (AUWO) were two of the parameters of great interest since throughout in vitro and in vivo experiments their variability was lower than 15.79%. AUC and AUWO appear to be the most reliable parameters for assessing tumor perfusion using DCE-US as they exhibited the lowest CV values.

  5. Use of ultrasonography to identify late-stage maturity in rainbow trout Oncorhynchus mykiss

    USDA-ARS?s Scientific Manuscript database

    Morphometric measurements by ultrasonography has been used to determine gonad and follicle size in many species of fish for purposes of identifying sex and estimating stage of maturation. We have been using a portable ultrasound system (SonoSite MicroMaxx, L25e/13-6 MHz transducer) to identify fem...

  6. FE Yurchikhin poses for a photo with SonoCard

    NASA Image and Video Library

    2010-06-25

    ISS024-E-006664 (25 June 2010) --- With most of his body tucked away in a sleeping bag, Russian cosmonaut Fyodor Yurchikhin, Expedition 24 flight engineer, is pictured in his crew quarters compartment in the Zvezda Service Module of the International Space Station.

  7. Factors associated with poor sleep quality in women with cancer.

    PubMed

    Mansano-Schlosser, Thalyta Cristina; Ceolim, Maria Filomena

    2017-03-02

    Ecuaciones de Estimación Generalizada. la depresión y el dolor contribuyeron para el aumento del puntaje del Índice de Calidad del Sueño de Pittsburgh y la esperanza para la reducción del puntaje, de manera independiente, a lo largo del seguimiento. Los trastornos del sueño fueron el componente con puntuación más elevada, a lo largo del seguimiento. la presencia de la depresión y del dolor, previos a la cirugía, contribuyeron para el aumento del puntaje global del Índice de Calidad del Sueño de Pittsburgh, lo que indica peor calidad del sueño, a lo largo del seguimiento y, la mayor esperanza, a su vez, influenció en la reducción del puntaje del Índice de Calidad del Sueño de Pittsburgh. analisar os fatores associados à má qualidade do sono, suas características e componentes em mulheres com câncer de mama antes da cirurgia de retirada do tumor e ao longo do seguimento. estudo longitudinal, em hospital universitário com amostra de 102 mulheres. Foram utilizados: questionário de caracterização sociodemográfica e clínica, Índice de Qualidade do Sono de Pittsburgh; Inventário de Depressão de Beck; Escala de Esperança de Herth. Coleta compreendeu antes da cirurgia de retirada do tumor (T0) em T1, em média 3,2 meses; T2, em média 6,1 meses; T3, em média 12,4 meses. Utilizou-se estatística descritiva e o modelo de Equações de Estimação Generalizada. a depressão e a dor contribuíram para o aumento do escore do Índice de Qualidade de Sono de Pittsburgh, e a esperança, para a redução do escore, de maneira independente, ao longo do seguimento. Os transtornos do sono foram o componente com pontuação mais elevada, ao longo do seguimento. a presença de depressão e de dor, previamente à cirurgia, contribuiu para o aumento do escore global do Índice de Qualidade do Sono de Pittsburgh, o que indica pior qualidade do sono, ao longo do seguimento e, a maior esperança, por sua vez, influenciou na redução do escore do Índice de Qualidade do

  8. Estimation of intra-operator variability in perfusion parameter measurements using DCE-US

    PubMed Central

    Gauthier, Marianne; Leguerney, Ingrid; Thalmensi, Jessie; Chebil, Mohamed; Parisot, Sarah; Peronneau, Pierre; Roche, Alain; Lassau, Nathalie

    2011-01-01

    AIM: To investigate intra-operator variability of semi-quantitative perfusion parameters using dynamic contrast-enhanced ultrasonography (DCE-US), following bolus injections of SonoVue®. METHODS: The in vitro experiments were conducted using three in-house sets up based on pumping a fluid through a phantom placed in a water tank. In the in vivo experiments, B16F10 melanoma cells were xenografted to five nude mice. Both in vitro and in vivo, images were acquired following bolus injections of the ultrasound contrast agent SonoVue® (Bracco, Milan, Italy) and using a Toshiba Aplio® ultrasound scanner connected to a 2.9-5.8 MHz linear transducer (PZT, PLT 604AT probe) (Toshiba, Japan) allowing harmonic imaging (“Vascular Recognition Imaging”) involving linear raw data. A mathematical model based on the dye-dilution theory was developed by the Gustave Roussy Institute, Villejuif, France and used to evaluate seven perfusion parameters from time-intensity curves. Intra-operator variability analyses were based on determining perfusion parameter coefficients of variation (CV). RESULTS: In vitro, different volumes of SonoVue® were tested with the three phantoms: intra-operator variability was found to range from 2.33% to 23.72%. In vivo, experiments were performed on tumor tissues and perfusion parameters exhibited values ranging from 1.48% to 29.97%. In addition, the area under the curve (AUC) and the area under the wash-out (AUWO) were two of the parameters of great interest since throughout in vitro and in vivo experiments their variability was lower than 15.79%. CONCLUSION: AUC and AUWO appear to be the most reliable parameters for assessing tumor perfusion using DCE-US as they exhibited the lowest CV values. PMID:21512654

  9. Improving ovarian cancer imaging with LHRH-NBs: an experimental study.

    PubMed

    Li, Wenjuan; Zhang, Lingping; Zhu, Yuanfang; Zhang, Jinyi; Shen, Li; Huang, Shuying; Fang, Shanyu

    2016-09-01

    Our previous study used freeze-drying and biotin-avidin binding methods and obtained nontargeted nanobubbles (N-NBs) and ovarian cancer-targeting nanobubbles (LHRH-NBs, luteinizing hormone-releasing hormone nanobubbles). Our study also identified the physical and chemical properties of these two contrast agents, and validated the targeting ability and underlying mechanisms of LHRH-NBs in vitro. The present study investigated the imaging of N-NBs and LHRH-NBs in nude mice and their binding with tissues. The nude mice models of xenografts were divided into three groups, N-NB, LHRH-NB, and SonoVue. These contrast agents were injected via the caudal vein to observe the imaging of ovarian cancer. Fluorescence microscope was used to observe the penetration of N-NBs and LHRH-NBs through the vascular endothelial gaps. Immunofluorescence was used to observe the penetration of N-NBs and LHRH-NBs through vascular endothelial gaps and binding to the tumor cells. The imaging intensity and duration were not significantly different between N-NBs and LHRH-NBs. The imaging intensity in the N-NB and LHRH-NB groups was not significantly different compared with the SonoVue group; however, the imaging duration in the N-NB and LHRH-NB groups was significantly longer than in the SonoVue group (P < 0.001). Both N-NBs and LHRH-NBs penetrated through the vascular endothelial gaps. After penetrating through the vascular endothelial gapes, LHRH-NBs could target and bind to the tumor cells. N-NBs and LHRH-NBs are of good imaging effectiveness and relatively long imaging duration. LHRH-NB is a potent contrast agent for imaging ovarian cancer, while achieving targeted delivery of drugs to the site of ovarian cancer.

  10. Evaluation of optimal parameters for using low-dose computed tomography to diagnose urolithiasis

    NASA Astrophysics Data System (ADS)

    Chen, Hui-Hsien; Yu, Cheng-Ching; Hsu, Fang-Yuh

    2017-11-01

    Urolithiasis is a common disease; patients suspected of suffering from urolithiasis will be examined by abdomen x-ray, Sono, Intraudio Videonous Urography (IVU) and Computed Tomography (CT). The detection rates for calculus in above examinations are respectively: 50-70% (x-ray), 50-60% (Sono), 70-90% (IVU) and 97% (CT). In addition, the effective doses are respectively: 0.63 mSv (x-ray), no radiation dose (Sono), 2.6 mSv (IVU) and 8-16 mSv (CT). Although CT has the highest detection rate for calculus, it also has the highest radiation dose. This research sought to lower the radiation dose by using CT scans with different dose conditions of standard dose (SD), 50% SD, 25% SD, and 15% SD to diagnose patients who suffer from urolithiasis and thus explore the feasibility of examining urolithiasis via CT with lower dose conditions. This research simulated the examination of patients with RANDO phantom, collocating PMMA slice phantom and pig's kidney. Fake calculuses made of five different materials of different sizes were put into the phantom and scanned individually. The results of the scanned images were given to two physicians who had many years of diagnostic experience to interpret the urolithiasis images. This study explored the different image qualities of CT with different dose conditions. In addition, this research used thermoluminescent dosimeters (TLD) to measure the radiation doses and compared the results with the dose values shown on the screen of the CT scanner to estimate the dose conversion factor (k). The research results showed that a low-dose CT was able to provide good image quality and thus have a lower radiation dose. Therefore, a low-dose CT is suggested the main examination method to diagnose patients with urolithiasis.

  11. [Mortality from respiratory diseases in the provinces of Apulia Region (Southern Italy) from 1933 to 2010].

    PubMed

    Montinari, Maria Rosa; Gianicolo, Emilio Antonio Luca; Vigotti, Maria Angela

    2016-01-01

    OBIETTIVI: valutare l'andamento temporale della mortalità per patologie respiratorie nelle province pugliesi utilizzando dati omogenei per fonte e metodologia di calcolo. DISEGNO: analisi ecologica storica degli andamenti temporali di mortalità per tumori e patologie dell'apparato respiratorio nelle province pugliesi, in Puglia e nelle ripartizioni geografiche italiane dal 1933 al 2010. SETTING E PARTECIPANTI: i dati di mortalità e le popolazioni residenti sono di fonte Istat. Sono state esaminate tutte le cause di decesso, il tumore della laringe, il tumore del polmone, l'insieme dei tumori respiratori, la bronchite, la polmonite e la broncopolmonite considerate congiuntamente, e l'insieme delle patologie respiratorie. Le analisi sono disaggregate per sesso dal 1969. PRINCIPALI MISURE DI OUTCOME: rapporti standardizzati di mortalità (SMR%) in riferimento all'Italia, con intervalli di confidenza al 95%, e tassi di mortalità standardizzati col metodo diretto (TSD ) in riferimento alla popolazione standard europea. RISULTATI: dal 1933 al 2010, i TSD per tumori respiratori e per bronchiti diminuiscono in tutte le aree analizzate. Tuttavia, nelle province di Taranto, Brindisi e Lecce, l'SMR% per tumori respiratori, inferiore al riferimento nazionale fino agli anni Sessanta, si allinea (a Brindisi) e supera (a Lecce e Taranto) il riferimento negli anni successivi. Nelle province di Foggia e Bari il numero dei decessi per tumore del polmone è costantemente inferiore all'atteso. CONCLUSIONI: la ricostruzione storica e l'analisi dei trend temporali di mortalità dal 1933 al 2010 mostrano alcune criticità sanitarie in periodi specifici. L'elaborazione dei dati di mortalità per un arco temporale di circa 80 anni ha messo in evidenza la maggiore rilevanza di queste criticità con l'avvio dello sviluppo industriale.

  12. Central radio galaxies in groups: cavities, bubbles and the history of AGN heating

    NASA Astrophysics Data System (ADS)

    Giacintucci, S.; Venturi, T.; Raychaudhury, S.; Vrtilek, J.

    2008-10-01

    E' noto che le regioni centrali degli ammassi e gruppi di galassie costituiscono un ambiente in cui gas caldo e plasma radioemittente proveniente dalle galassie dominanti interagiscono tra loro. In particolare, si pensa che la radioemissione dell'AGN centrale ed i suoi possibili cicli di attivita', siano strettamente legati alla presenza di cavita' e "bubbles" nel gas intergalattico. Si presentera' lo status di un progetto osservativo effettuato con il Giant Metrewave Radio Telescope (GMRT, India) su di un campione di 18 gruppi di galassie, osservati a tre frequenze radio (235 MHz, 325 MHz e 610 MHz). Lo studio della morfologia radio degli AGN centrali e la relativa analisi spettrale permettono di ottenere stime sull'eta' di questi oggetti, e sulla loro energia totale, che a loro volta sono in relazione con le proprieta' X dei gruppi stessi. Per tutti gli oggetti del campione sono disponibili osservazioni Chandra di proprieta'. Per due oggetti del campione, 4C+24.36 (al centro di AWM04) e NGC741 (al centro di RSOG17) verra' presentato uno studio dettagliato.

  13. DFT studies on the mechanism of the reaction of C2H5S with NO2

    NASA Astrophysics Data System (ADS)

    Tang, Yi-Zhen; Sun, Hao; Pan, Ya-Ru; Pan, Xiu-Mei; Wang, Rong-Shun

    The mechanisms for the reaction of C2H5S with NO2 are investigated at the QCISD(T)/6-311++G(d, p)//B3LYP/6-311++G(d, p) level on both single and triple potential energy surfaces. The geometries, vibrational frequencies and zero-point energy (ZPE) corrections of all stationary points involved in the title reaction are calculated at the B3LYP/6-311++G(d, p) level. The results show that the reaction is more predominant on the single potential energy surface, while it is negligible on the triple potential energy surface. Without barrier height in the whole process, the major channel is R ? C2H5SONO (IM1 and IM2) ? P1 (C2H5SO+NO). With much heat released in the formation of C2H5SNO2 (IM3) and the transition state involved in the subsequent step more stable than reactants, P4 (CH3CHS + t-HONO) is subdominant product energetically.

  14. Microbubbles in macrocysts - Contrast-enhanced ultrasound assisted sclerosant therapy of a congenital macrocystic lymphangioma: a case report.

    PubMed

    Menendez-Castro, Carlos; Zapke, Maren; Fahlbusch, Fabian; von Goessel, Heiko; Rascher, Wolfgang; Jüngert, Jörg

    2017-07-06

    Congenital cystic lymphangiomas are benign malformations due to a developmental disorder of lymphatic vessels. Besides surgical excision, sclerosant therapy of these lesions by intracavitary injection of OK-432 (Picibanil®), a lyophilized mixture of group A Streptococcus pyogenes, is a common therapeutical option. For an appropriate application of OK-432, a detailed knowledge about the structure and composition of the congenital cystic lymphangioma is essential. SonoVue® is a commercially available contrast agent commonly used in sonography by intravenous and intracavitary application. Here we report the case of 2 month old male patient with a large thoracic congenital cystic lymphangioma. Preinterventional imaging of the malformation was performed by contrast-enhanced ultrasound after intracavitary application of SonoVue® immediately followed by a successful sclerotherapy with OK-432. Contrast agent-enhanced ultrasound imaging offers a valuable option to preinterventionally clarify the anatomic specifications of a congenital cystic lymphangioma in more detail than by single conventional sonography. By the exact knowledge about the composition and especially about the intercystic communications of the lymphangioma sclerosant therapy becomes safer and more efficient.

  15. Comparison of catalytic activities for photocatalytic and sonocatalytic degradation of organic dye in the presence of ternary Fe{sub 3}O{sub 4}/ZnO/CuO magnetic heteregenous nanocatalyst

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taufik, Ardiansyah; Saleh, Rosari, E-mail: rosari.saleh@gmail.com, E-mail: rosari.saleh@ui.ac.id; Integrated Laboratory of Energy and Environment, Fakultas MIPA-Universitas Indonesia, 16424 Depok

    2016-04-19

    The Fe{sub 3}O{sub 4}/ZnO/CuO nanocatalyst with various CuO loading were synthesized by sol-gel method and were characterized by powder X-ray diffraction, field emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, UV-Vis spectroscopy, and vibrating sample magnetometry. The findings demonstrate that all samples exhibit ferromagnetic behavior at room temperatureand containa well-crystalline ternary oxide nanocatalyst. Methylene blue was taken as the model of organic dye to evaluate its photocatalytic and sonocatalytic degradation in the presence of Fe{sub 3}O{sub 4}/ZnO/CuO nanocatalyst. The observed degradation activity indicate that the order of degradation of methylene blue issonocatalysis> photocatalysis. Fe{sub 3}O{sub 4}/ZnO/CuO nanocatalyst with the lowest CuOmore » loading exhibit the highest rate of degradation of methylene blue during the sono- and photocatalytic processes. The experimental data shows that holes are the predominant oxidative species involved in the sono- and photodegradation of methylene blue.« less

  16. Electrosynthesis of hydrogen peroxide via the reduction of oxygen assisted by power ultrasound.

    PubMed

    González-García, José; Banks, Craig E; Sljukić, Biljana; Compton, Richard G

    2007-04-01

    The electrosynthesis of hydrogen peroxide using the oxygen reduction reaction has been studied in the absence and presence of power ultrasound in a non-optimized sono-electrochemical flow reactor (20 cm cathodic compartment length with 6.5 cm inner diameter) with reticulated vitreous glassy carbon electrode (30 x 40 x 10 mm, 10 ppi, 7 cm(2)cm(-3)) as the cathode. The effect of several electrochemical operational variables (pH, volumetric flow, potential) and of the sono-electrochemical parameters (ultrasound amplitude and horn-to-electrode distance) on the cumulative concentration of hydrogen peroxide and current efficiency of the electrosynthesis process have been explored. The application of power ultrasound was found to increase both the cumulative concentration of hydrogen peroxide and the current efficiency. The application of ultrasound is therefore a promising approach to the increased efficiency of production of hydrogen peroxide by electrosynthesis, even in the solutions of lower pH (<12). The results demonstrate the feasibility of at-site-of-use green synthesis of hydrogen peroxide.

  17. [Trattamento del disturbo da uso di alcol da un punto di vista psicologico].

    PubMed

    Coriale, Giovanna; Fiorentino, Daniela; De Rosa, Francesca; Solombrino, Simona; Scalese, Bruna; Ciccarelli, Rosaria; Attilia, Fabio; Vitali, Mario; Musetti, Alessia; Fiore, Marco; Ceccanti, Mauro

    2018-01-01

    RIASSUNTO. L'elaborazione del piano di trattamento rappresenta un momento molto delicato e complesso del processo terapeutico del disturbo da abuso di alcol (DUA). È la fase in cui le informazioni raccolte da un'équipe di professionisti (medici, psicologi e assistenti sociali) (modello bio-psico-sociale del DUA) vengono messe insieme per decidere il percorso terapeutico più adatto. Per quanto riguarda la parte psicologica, è di notevole importanza scegliere un trattamento clinico in grado di ridurre al minimo la mancata adesione al trattamento e, per i soggetti che rimangono in trattamento, di garantirne l'efficacia. Se da una parte, le tecniche psicoanalitiche e comportamentali hanno fornito le basi della terapia psicologica dell'alcolismo, dall'altra, gli approcci basati sull'evidenza scientifica sono stati elaborati a partire dai principi del colloquio motivazionale e della terapia cognitivo-comportamentale. In questo articolo viene fornita una panoramica dei trattamenti che sono risultati più efficaci nel trattare il DUA e delle modalità temporali più adeguate per monitorare l'efficacia del trattamento.

  18. Misura della sezione d'urto totale e Dello scattering elastico all'energia Nel centro di massa di $$\\sqrt{s}=1.8$$ TeV (in Italian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paoletti, Riccardo

    La produzione di eventi elastici è stata misurata al Collider Tevatron del Fermi National Accelerator Laboratory (Batavia. 11.~ U .S.A.) alla energia nel centro di massa. di √s = 1800 GeV, nell'intervallo 0.06 < I t I< 0.24. Sono forniti dettagli sull'esperimento CDF che ha compiuto la misura e sui criteri di selezione degli eventi.

  19. Aortopexy for the treatment of tracheomalacia in children: review of the literature

    PubMed Central

    2012-01-01

    delicate is represented by those with associated gastro-esophageal reflux, in whom a fundoplication should be performed. Other treatments of tracheomalacia, particularly tracheal stenting, were associated with a higher rate of failure, severe morbidity and mortality. Non english abstract La tracheomalacia severa rappresenta una sfida per Pediatri, Intensivisti, Pneumologi, Otorinolaringoiatri, Chirurghi Pediatri. Il trattamento della tracheomalacia è tuttora controverso. L’aortopessi è considerata da molti la migliore opzione terapeutica. Abbiamo condotto una revisione della letteratura di lingua inglese su tale argomento. Di 125 lavori, 40 sono stati inclusi nella revisione. Tra 758 pazienti (62% maschi) affetti da tracheomalacia, 581 sono stati sottoposti ad aortopessi tra il 1968 e il 2008. In 659 pazienti alcune comorbidità erano presenti. L’associazione più frequente era con l’atresia esofagea (44%), l’anello vascolare o un’anomalia dei grossi vasi (18%), la compressione da parte dell’arteria innominata (16%); nel 9% la tracheomalacia era idiopatica. I sintomi riportati sono stati variabili, ma l’indicazione più importante all’aortopessi sono stati eventi di ALTE, osservati nel 43% dei pazienti. Lo studio diagnostico preoperatorio principale è stato la broncoscopia. L’approccio chirurgico è avvenuto attraverso una toracotomia anteriore sinistra nel 72% dei pazienti, mentre un approccio mediano è stato scelto nel 14% e nell’1.3% dei casi è stato eseguito un approccio toracoscopico. Al follow-up (mediana di 47 mesi) la maggioranza dei pazienti sono migliorati significativamente, ma l’8% di essi non è migliorato, il 4% è peggiorato e il 6% è morto. Complicazioni sono state riportate nel 15% dei pazienti, nell’1% un nuovo intervento di aortopessi è stato necessario. In questa revisione abbiamo trovato che non c’è un consenso generale sulla valutazione e sulla descrizione dei sintomi, sulle indicazioni chirurgiche ed esami

  20. Study and Characterization of Subharmonic Emissions by Using Shaped Ultrasonic Driving Pulse

    NASA Astrophysics Data System (ADS)

    Masotti, L.; Biagi, E.; Breschi, L.; Vannacci, E.

    Subharmonic emissions from Ultrasound Contrast Agents (UCAs) were studied by a Pulse Inversion method in order to assess the feasibility of implementation of this technique to subharmonic imaging. Interesting results concerning the dependence of the subharmonic emission with respect to initial pulse shape are presented. The experimentation was performed also by varying the acoustic pressure and concentration of the contrast agent (SonoVue®)

  1. [Validation of a new hand-carried ultrasound device equipped with directional color power Doppler and continuous wave Doppler].

    PubMed

    Kawai, Junichi; Tanabe, Kazuaki; Matsuzaki, Masashi; Yamaguchi, Kazuto; Yagi, Toshikazu; Fujii, Yoko; Konda, Toshiko; Ui, Kazuyo; Sumida, Toshiaki; Okada, Midori; Tani, Tomoko; Morioka, Shigefumi

    2003-10-01

    This study evaluated the accuracy of the directional color power Doppler (DCPD) and continuous wave Doppler (CWD) methods incorporated in the new hand-carried SonoSite 180PLUS ultrasound device. The hand-held ultrasound system with 2.5 MHz transducer and SONOS 5500 was used as a standard ultrasound system with a 2 to 4 MHz wideband transducer. The experimental study used a Doppler wire phantom to evaluate the influence of target wire speed and angle of transducer on DCPD imaging. The clinical study included 48 consecutive patients. DCPD assessment of valvular regurgitation measured the distances of DCPD signals of mitral, aortic and tricuspid valve regurgitation using the apical four-chamber view for comparison with standard echocardiography. CWD assessment measured the peak velocities of the aortic flow and tricuspid valve regurgitant flow for comparison with standard echocardiography. In the experimental study, DCPD signals were not influenced by target wire speed changes and transducer incident angles. In the clinical study, agreements for mitral, aortic and tricuspid regurgitation between the two methods were 89.6%, 81.8% and 78.7%, respectively. The distances of DCPD valve regurgitant signals by the hand-carried ultrasound device showed good correlation (mitral regurgitation: y = 0.84x + 0.55; r = 0.93, aortic regurgitation: y = 0.95x + 0.27; r = 0.94, tricuspid regurgitation: y = 0.86x + 0.61; r = 0.90) with those by standard echocardiography. Evaluation of CWD velocity measurements showed good agreement for the lower flow velocities (< 2.0 m/sec). However, underestimation occurred for the high flow velocities (> 2.0 m/sec) compared with those by standard echocardiography (aortic flow: y = 0.80x + 0.11; r = 0.95, tricuspid regurgitation: y = 1.00x - 0.23; r = 0.90). The new hand-carried ultrasound device (SonoSite 180PLUS equipped with DCPD and CWD) is clinically useful for evaluating valvular regurgitations and flow velocities. Further studies are needed to

  2. [Evaluation of mercury exposure in populations living near the industrial Augusta Bay (Sicily Region, Southern Italy)].

    PubMed

    Bonsignore, Maria; Andolfi, Nunzia; Quinci, Enza Maria; Madeddu, Anselmo; Tisano, Francesco; Ingallinella, Vincenzo; Castorina, Maria; Sprovieri, Mario

    2016-01-01

    OBIETTIVI: valutare e quantificare l'esposizione umana al mercurio (Hg) ed esplorare i fattori chiave che influenzano la contaminazione nelle popolazioni residenti in prossimità della Rada di Augusta, un'area a elevato rischio ambientale a causa degli effetti degli sversamenti incontrollati di Hg da parte di uno dei più grandi impianti cloro-soda d'Europa. DISEGNO: un campione di residenti nei comuni di Augusta, Priolo e Melilli (Sicilia orientale) è stato selezionato per lo studio di biomonitoraggio umano. Un questionario dettagliato è stato somministrato a ogni partecipante per raccogliere informazioni anagrafiche sulle abitudini di vita e alimentari. I livelli di Hg in sangue e capelli, usati come traccianti di esposizione a metilmercurio, sono stati messi in relazione al consumo di pesce locale. Il contenuto di Hg nelle urine è stato utilizzato per esplorare eventuali esposizioni atmosferiche a Hg inorganico. Una regressione lineare multivariata è stata applicata con l'obiettivo di esplorare i fattori che influenzano l'esposizione umana al Hg. L'approccio tossicocinetico è stato impiegato al fine di calcolare la dose settimanale provvisoria tollerabile ( provisional tolerable weekly intake, PTWI) e di predire le concentrazioni di Hg attese nel sangue degli individui con una dieta alimentare basata esclusivamente su pesce locale. 224 individui residenti nei comuni di Augusta, Melilli e Priolo. RISULTATI: eccessi di Hg sono stati misurati nel sangue e nei capelli del campione considerato. I più alti livelli sono stati rilevati ad Augusta, dove anche il consumo di pesce locale risulta maggiore. I valori di dose settimanale tollerabile provvisoria (PTWI) calcolati eccedono, nella maggior parte dei casi, le raccomandazioni internazionali, specialmente nei residenti ad Augusta. CONCLUSIONI: gli elevati livelli di Hg registrati nei campioni di sangue e capelli derivano, con ogni probabilità, dal consumo di pesce locale. Rispetto ad Augusta, gli individui di

  3. Sleep, quality of life and mood of nursing professionals of pediatric intensive care units.

    PubMed

    Guerra, Priscilla Caetano; Oliveira, Nilton Ferraro; Terreri, Maria Teresa de Sande E Lemos Ramos Ascensão; Len, Claudio Arnaldo

    2016-04-01

    To assess sleep, quality of life and mood of nursing professionals of pediatric intensive care units. Quantitative, cross-sectional and descriptive study. Professionals grouped by morning, afternoon and evening shifts were assessed by means of the instruments: Morningness-Eveningness Questionnaire; Pittsburgh Sleep Quality Index; Epworth Sleepiness Scale; Generic questionnaire for the assessment of quality of life (SF-36); Beck Depression Inventory; Beck Anxiety Inventory; State-Trait Anxiety Inventory. Sample consisted of 168 professionals, with prevalence of neutral typology (57.49%). There was no statistical significance regarding sleep, despite scores showing a poor quality of sleep and excessive daytime sleepiness for the three shifts. Quality of life did not reveal any statistical significance, but in the field "social role functioning" of the evening shift, a lower score was observed (p<0.007). There was no statistical significance regarding levels of anxiety and depression. The results suggest that these professionals may present sleeping problems, but they do not have lower scores of quality of life or mood disorders. Likely explanations for these findings may include an adaptation to their work type over time and the fact that working with children is rewarding. Avaliar sono, qualidade de vida e humor em profissionais de enfermagem em Unidades de Terapia Intensiva Infantil. Estudo quantitativo, transversal e descritivo. Profissionais agrupados por turnos matutino, vespertino e noturno foram avaliados pelos instrumentos: Questionário de identificação Matutinidade-Vespertinidade; Índice de qualidade do sono de Pittsburgh; Escala de sonolência Epworth; Questionário genérico de avaliação de qualidade de vida - SF-36; Inventário de depressão de Beck; Inventário de ansiedade de Beck; Inventário de ansiedade Traço-Estado. Amostra composta por 168 profissionais, predominando tipologia neutra, 57,49%. Não houve significância estatística quanto ao

  4. Improving the sludge disintegration efficiency of sonication by combining with alkalization and thermal pre-treatment methods.

    PubMed

    Şahinkaya, S; Sevimli, M F; Aygün, A

    2012-01-01

    One of the most serious problems encountered in biological wastewater treatment processes is the production of waste activated sludge (WAS). Sonication, which is an energy-intensive process, is the most powerful sludge pre-treatment method. Due to lack of information about the combined pre-treatment methods of sonication, the combined pre-treatment methods were investigated and it was aimed to improve the disintegration efficiency of sonication by combining sonication with alkalization and thermal pre-treatment methods in this study. The process performances were evaluated based on the quantities of increases in soluble chemical oxygen demand (COD), protein and carbohydrate. The releases of soluble COD, carbohydrate and protein by the combined methods were higher than those by sonication, alkalization and thermal pre-treatment alone. Degrees of sludge disintegration in various options of sonication were in the following descending order: sono-alkalization > sono-thermal pre-treatment > sonication. Therefore, it was determined that combining sonication with alkalization significantly improved the sludge disintegration and decreased the required energy to reach the same yield by sonication. In addition, effects on sludge settleability and dewaterability and kinetic mathematical modelling of pre-treatment performances of these methods were investigated. It was proven that the proposed model accurately predicted the efficiencies of ultrasonic pre-treatment methods.

  5. Thermal dependence of ultrasound contrast agents scattering efficiency for echographic imaging techniques

    NASA Astrophysics Data System (ADS)

    Biagioni, Angelo; Bettucci, Andrea; Passeri, Daniele; Alippi, Adriano

    2015-06-01

    Ultrasound contrast agents are used in echographic imaging techniques to enhance image contrast. In addition, they may represent an interesting solution to the problem of non-invasive temperature monitoring inside the human body, based on some thermal variations of their physical properties. Contrast agents, indeed, are inserted into blood circulation and they reach the most important organs inside the human body; consequently, any thermometric property that they may possess, could be exploited for realizing a non-invasive thermometer. They essentially are a suspension of microbubbles containing a gas enclosed in a phospholipid membrane; temperature variations induce structural modifications of the microbubble phospholipid shell, thus causing thermal dependence of contrast agent's elastic characteristics. In this paper, the acoustic scattering efficiency of a bulk suspension of of SonoVue® (Bracco SpA Milan, Italy) has been studied using a pulse-echo technique in the frequency range 1-17 MHz, as it depends upon temperatures between 25 and 65°C. Experimental data confirm that the ultrasonic attenuation coefficient of SonoVue® depends on temperature between 25 and 60°C. Chemical composition of the bubble shell seem to support the hypothesis that a phase transition in the microstructure of lipid-coated microbubbles could play a key role in explaining such effect.

  6. A hot hole-programmed and low-temperature-formed SONOS flash memory

    PubMed Central

    2013-01-01

    In this study, a high-performance TixZrySizO flash memory is demonstrated using a sol–gel spin-coating method and formed under a low annealing temperature. The high-efficiency charge storage layer is formed by depositing a well-mixed solution of titanium tetrachloride, silicon tetrachloride, and zirconium tetrachloride, followed by 60 s of annealing at 600°C. The flash memory exhibits a noteworthy hot hole trapping characteristic and excellent electrical properties regarding memory window, program/erase speeds, and charge retention. At only 6-V operation, the program/erase speeds can be as fast as 120:5.2 μs with a 2-V shift, and the memory window can be up to 8 V. The retention times are extrapolated to 106 s with only 5% (at 85°C) and 10% (at 125°C) charge loss. The barrier height of the TixZrySizO film is demonstrated to be 1.15 eV for hole trapping, through the extraction of the Poole-Frenkel current. The excellent performance of the memory is attributed to high trapping sites of the low-temperature-annealed, high-κ sol–gel film. PMID:23899050

  7. Improved extraction of avocado oil by application of sono-physical processes.

    PubMed

    Martínez-Padilla, Laura Patricia; Franke, Lisa; Xu, Xin-Qing; Juliano, Pablo

    2018-01-01

    Ultrasound treatment is known to increase the oil extractability in olive and palm oil processes. This work examined the effect of ultrasound conditioning of avocado puree on oil extractability and quality, at low (18+40kHz) and high (2MHz) frequencies, at litre-scale. Other ultrasound parameters evaluated included high frequency effect (0.4, 0.6, and 2MHz; 5min; 90kJ/kg) and sonication time (2.5-10min at 2MHz), without malaxation. Finally, a megasonic post-malaxation intervention was assessed at selected malaxation times (15, 30, and 60min). Both low and high frequency ultrasound treatments of the non-malaxed avocado puree improved extractability by 15-24% additional oil recovery, with the highest extractability achieved after 2MHz treatments, depending on the fruit maturity and oil content. There was no preferential improvement on oil extractability observed across high frequencies, even though extractability increased with sonication time. Ultrasound treatment also showed a positive effect after puree malaxation. Oils obtained from sonicated purees showed peroxide and free fatty acid values below the industrial specification levels and an increase in total phenolic compounds after 2MHz treatment. High frequency ultrasound conditioning of avocado puree can enhance oil separation and potentially decrease the malaxation time in industrial processes without impacting on oil quality. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Disegno dello studio genomico, ambientale, microbiomico e metabolomico sulla celiachia: un approccio al futuro della prevenzione personalizzata della celiachia

    PubMed Central

    SERENA, GLORIA; LEONARD, MAUREEN M.; CAMHI, STEPHANIE; HUEDO-MEDINA, TANIA B.; FASANO, ALESSIO

    2017-01-01

    Riassunto Negli ultimi anni abbiamo assistito a un fiorire di novità cliniche e scientifiche sulla celiachia (CE), ma forse la novità più importante che influenzerà il futuro della ricerca e della clinica in questo campo riguarda la storia naturale della malattia. Per molti anni si è creduto che la predisposizione genetica e l’esposizione al glutine fossero necessarie e sufficienti allo sviluppo della CE. Studi recenti, però suggeriscono che la perdita di tolleranza al glutine possa apparire in qualsiasi momento della vita a seguito di altri elementi. Inoltre, diversi fattori ambientali conosciuti per il loro ruolo nell’influenzare la composizione della microflora intestinale sono anche stati considerati legati allo sviluppo della CE. Tra questi fattori sono inclusi la modalità di parto, la dieta dell’infante e l’uso di antibiotici. A tutt’oggi, nessuno studio longitudinale di ampia scala ha determinato se e come la composizione del microbioma e il suo profilo metabolomico possano influenzare la perdita di tolleranza al glutine e il successivo sviluppo della CE in soggetti geneticamente predisposti. In questo articolo descriviamo uno studio prospettico, multicentrico e longitudinale su infanti a rischio per la CE che utilizzerà diverse tecniche per approfondire il ruolo che il microbioma intestinale ha durante i primi passaggi dello sviluppo della malattia autoimmune. PMID:27362724

  9. Investigation of Microbubble Cavitation-Induced Calcein Release from Cells In Vitro.

    PubMed

    Maciulevičius, Martynas; Tamošiūnas, Mindaugas; Jakštys, Baltramiejus; Jurkonis, Rytis; Venslauskas, Mindaugas Saulius; Šatkauskas, Saulius

    2016-12-01

    In the present study, microbubble (MB) cavitation signal analysis was performed together with calcein release evaluation in both pressure and exposure duration domains of the acoustic field. A passive cavitation detection system was used to simultaneously measure MB scattering and attenuation signals for subsequent extraction efficiency relative to MB cavitation activity. The results indicate that the decrease in the efficiency of extraction of calcein molecules from Chinese hamster ovary cells, as well as cell viability, is associated with MB cavitation activity and can be accurately predicted using inertial cavitation doses up to 0.18 V × s (R 2  > 0.9, p < 0.0001). No decrease in additional calcein release or cell viability was observed after complete MB sonodestruction was achieved. This indicates that the optimal exposure duration within which maximal sono-extraction efficiency is obtained coincides with the time necessary to achieve complete MB destruction. These results illustrate the importance of MB inertial cavitation in the sono-extraction process. To our knowledge, this study is the first to (i) investigate small molecule extraction from cells via sonoporation and (ii) relate the extraction process to the quantitative characteristics of MB cavitation acoustic spectra. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  10. Calibrazioni a terra e prestazioni in volo di spettrometri ad immagine nel visibile e nel vicino infrarosso per l'esplorazione planetaria

    NASA Astrophysics Data System (ADS)

    Filacchione, Gianrico

    2006-10-01

    Nel corso dell’ultimo decennio l’esplorazione planetaria ha potuto beneficiare dei dati prodotti dagli spettrometri ad immagine: grazie a questa nuova classe di strumenti, realizzati per l’osservazione in remoto di superfici ed atmosfere planetarie, è possibile acquisire dati iperspettrali con elevati poteri risolutivi spaziali e spettrali. Il principale vantaggio offerto dagli spettrometri ad immagine, rispetto alle camere ed agli spettrometri puntuali, è rappresentato dalla capacità di misurare, identificare e mappare le unità composizionali delle superfici planetarie; queste informazioni permettono di investigare sia l’evoluzione geochimica delle superfici sia la dinamica e la composizione delle atmosfere. Sebbene i primi spettrometri ad immagine siano stati francesi (Phobos/ISM, Imaging Spectrometer for Mars) e statunitensi (Galileo/NIMS, Near Infrared Mapping Spectrometer), il nostro paese nel corso degli ultimi anni è stato in grado di proporre alla com unità spaziale internazionale degli strumenti dalle elevate prestazioni che sono stati infatti accettati come payload scientifici su diverse missioni interplanetarie: dai canali visibili di VIMS (Visual and Infrared Mapping Spectrometer) su Cassini (Nasa, JPL, ESA, ASI) e di OMEGA (Observatoire pour la Minéralogie, l’Eau, les Glacies et l’Activitè de Mars) su MarsExpress (ESA) ai due VIRTIS (Visible and Infrared Thermal Imaging Spectrometer) su Rosetta (ESA) e VenusExpress (ESA) fino a VIR-MS (Visible and Infrared Mapping Spectrometer) su Dawn (Nasa). In questo momento inoltre altri due spettrometri sono in avanzata fase di studio: JIRAM (Jovian InfraRed Auroral Mapper) su Juno (missione New Discovery Nasa) e VIHI (Visible and Infrared Hyperspectral Imager) integrato nel payload italiano di remote sensing SIMBIO-SYS di BepiColombo (missione cornerstone ESA). La realizzazione di uno spettrometro ad immagini da utilizzare su una missione interplanetaria richiede un’accurata analisi in fase

  11. Association of subclinical inflammation, glycated hemoglobin and risk for obstructive sleep apnea syndrome.

    PubMed

    D'Aurea, Carolina Vicaria Rodrigues; Cerazi, Bruno Gion de Andrade; Laurinavicius, Antonio Gabriele; Janovsky, Carolina Castro Porto Silva; Conceição, Raquel Dilguerian de Oliveira; Santos, Raul D; Bittencourt, Márcio Sommer

    2017-01-01

    To investigate the inter-relation between high sensitivity C-reactive protein and glycated hemoglobin in prediction of risk of obstructive sleep apnea. We included all individuals participating in a check-up program at the Preventive Medicine Center of Hospital Israelita Albert Einstein in 2014. The Berlin questionnaire for risk of obstructive sleep apnea was used, and the high sensitivity C-reactive protein and glycated hemoglobin levels were evaluated. The sample included 7,115 participants (age 43.4±9.6 years, 24.4% women). The Berlin questionnaire showed changes in 434 (6.1%) individuals. This finding was associated with high sensitivity C-reactive protein and glycated hemoglobin levels (p<0.001). However, only the association between the Berlin questionnaire result and glycated hemoglobin remained significant in the adjusted multivariate analysis, for the traditional risk factors and for an additional model, including high-density lipoprotein cholesterol and triglycerides. The glycated hemoglobin, even below the threshold for diagnosis of diabetes, is independently associated with obstructive sleep apnea syndrome, even after adjustment for obesity and C-reactive protein. These findings suggest a possible pathophysiological link between changes in insulin resistance and obstructive sleep apnea syndrome, independently from obesity or low-grade inflammation. Investigar a inter-relação entre proteína C-reativa de alta sensibilidade e hemoglobina glicada na predição do risco de apneia obstrutiva do sono. Foram incluídos todos os indivíduos participantes do programa de check-up do Centro de Medicina Preventiva Hospital Israelita Albert Einstein em 2014. Foi aplicado o questionário de Berlin sobre risco de apneia do sono, e avaliadas as dosagens de hemoglobina glicada e proteína C-reativa de alta sensibilidade. Foram incluídos 7.115 participantes (idade 43,4±9,6 anos, 24,4% mulheres). A prevalência de alteração no questionário de Berlin foi de 434 (6

  12. Sono-chemical synthesis of cellulose nanocrystals from wood sawdust using Acid hydrolysis.

    PubMed

    Shaheen, Th I; Emam, Hossam E

    2018-02-01

    Cellulose nanocrystal (CNC) is a unique material obtained from naturally occurring cellulose fibers. Owing to their mechanical, optical, chemical, and rheological properties, CNC gained significant interest. Herein, we investigate the potential of commercially non-recyclable wood waste, in particular, sawdust as a new resource for CNC. Isolation of CNC from sawdust was conducted as per acid hydrolysis which induced by ultrasonication technique. Thus, sawdust after being alkali delignified prior sodium chlorite bleaching, was subjected to sulfuric acid with concentration of 65% (w/w) at 60 ° C for 60min. After complete reaction, CNC were collected by centrifugation followed by dialyzing against water and finally dried via using lyophilization technique. The CNC yield attained values of 15% from purified sawdust. Acid hydrolysis mechanism exactly referred that, the amorphous regions along with thinner as well as shorter crystallites spreaded throughout the cellulose structure are digested by the acid leaving CNC suspension. The latter was freeze-dried to produce CNC powder. A thorough investigation pertaining to nanostructural characteristics of CNC was performed. These characteristics were monitored using TEM, SEM, AFM, XRD and FTIR spectra for following the changes in functionality. Based on the results obtained, the combination of sonication and chemical treatment was great effective in extraction of CNC with the average dimensions (diameter×length) of 35.2±7.4nm×238.7±81.2nm as confirmed from TEM. Whilst, the XRD study confirmed the crystal structure of CNC is obeyed cellulose type I with crystallinity index ∼90%. Cellulose nanocrystals are nominated as the best candidate within the range studied in the area of reinforcement by virtue of their salient textural features. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Merging microfluidics and sonochemistry: towards greener and more efficient micro-sono-reactors.

    PubMed

    Fernandez Rivas, David; Cintas, Pedro; Gardeniers, Han J G E

    2012-11-18

    Microfluidics enable the manipulation of chemical reactions using very small amounts of fluid, in channels with dimensions of tens to hundreds of micrometers; so-called microstructured devices, from which the iconic image of chips emerges. The immediate attraction of microfluidics lies in its greenness: use of small quantities of reagents and solvents, and hence less waste, a precise control of reaction conditions, integration of functionality for process intensification, safer and often faster protocols, reliable scale-up, and possibility of performing multiphase reactions. Among the limitations found in microfluidics the facile formation of precipitating products should be highlighted, and in this context, the search for efficient mass and energy transfers is a must. Such limitations have been partially overcome with the aid of ultrasound in conventional flow systems, and can now be successfully used in microreactors, which provide new capabilities. Novel applications and a better understanding of the physical and chemical aspects of sonochemistry can certainly be achieved by combining microfluidics and ultrasound. We will review this nascent area of research, paying attention to the latest developments and showing future directions, which benefit both from the existing microfluidic technology and sonochemistry itself.

  14. Elaborazione dei dati sperimentali

    NASA Astrophysics Data System (ADS)

    Dapor, M.; Ropele, M.

    L'analisi statistica dei dati sperimentali, la loro elaborazione ed una corretta stima degli errori sono conoscenze necessarie agli studenti di fisica, biologia, chimica, ingegneria e dei corsi di specializzazione tecnico-scientifici in cui a di laboratorio. Chi si occupa di problemi tecnici e di misure, per studio o per lavoro, deve possedere gli strumenti matematici di calcolo e di analisi necessari ad una corretta interpretazione dei dati sperimentali. Il testo fornisce in modo sintetico, chiaro ed esaustivo, tutte le nozioni e le conoscenze utili allo scopo.

  15. Combination of Sonodynamic and Photodynamic Therapy against Cancer Would Be Effective through Using a Regulated Size of Nanoparticles

    PubMed Central

    Miyoshi, N.; Kundu, S. K.; Tuziuti, T.; Yasui, K.; Shimada, I.; Ito, Y.

    2016-01-01

    Nanoparticles have been used for many functional materials in nano-sciences and photo-catalyzing surface chemistry. The titanium oxide nanoparticles will be useful for the treatment of tumor by laser and/or ultrasound as the sensitizers in nano-medicine. We have studied the combination therapy of photo- and sono-dynamic therapies in an animal tumor model. Oral-administration of two sensitizers titanium oxide, 0.2%-TiO2 nanoparticles for sono-dynamic and 1 mM 5-aminolevulinic acid for photodynamic therapies have resulted in the best combination therapeutic effects for the cancer treatment. Our light microscopic and Raman spectroscopic studies revealed that the titanium nanoparticles were distributed inside the blood vessel of the cancer tissue (1–3 μm sizes). Among these nanoparticles with a broad size distribution, only particular-sized particles could penetrate through the blood vessel of the cancer tissue, while other particles may only exhibit the side effects in the model mouse. Therefore, it may be necessary to separate the optimum size particles. For this purpose we have separated TiO2 nanoparticles by countercurrent chromatography with a flat coiled column (1.6 mm ID) immersed in an ultrasonic bath (42 KHz). Separation was performed with a two-phase solvent system composed of 1-butanol-acetic acid-water at a volume ratio of 4:1:5 at a flow rate of 0.1 ml/min. Countercurrent chromatographic separation yielded fractions containing particle aggregates at 31 and 4400 nm in diameter. PMID:27088115

  16. Comparison microbial killing efficacy between sonodynamic therapy and photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Drantantiyas, Nike Dwi Grevika; Astuti, Suryani Dyah; Nasution, Aulia M. T.

    2016-11-01

    Biofilm is a way used by bacteria to survive from their environmental conditions by forming colony of bacteria. Specific characteristic in biofilm formation is the availability of matrix layer, known as extracellular polymer substance. Treatment using antibiotics may lead bacteria to be to resistant. Other treatments to reduce microbial, like biofilm, can be performed by using photodynamic therapy. Successful of this kind of therapy is induced by penetration of light and photosensitizer into target cells. The sonodynamic therapy offers greater penetrating capability into tissues. This research aimed to use sonodynamic therapy in reducing biofilm. Moreover, it compares also the killing efficacy of photodynamic therapy, sonodynamic therapy, and the combination of both therapeutic schemes (known as sono-photodynamic) to achieve higher microbial killing efficacy. Samples used are Staphylococcus aureus biofilm. Treatments were divided into 4 groups, i.e. group under ultrasound treatment with variation of 5 power levels, group of light treatment with exposure of 75s, group of combined ultrasound-light with variation of ultrasound power levels, and group of combined lightultrasound with variation of ultrasound power levels. Results obtained for each treatment, expressed in % efficacy of log CFU/mL, showed that the treatment of photo-sonodynamic provides greater killing efficacy in comparison to either sonodynamic and sono-photodynamic. The photo-sonodynamic shows also greater efficacy to photodynamic. So combination of light-ultrasound (photo-sonodynamic) can effectively kill microbial biofilm. The combined therapy will provide even better efficacy using exogenous photosensitizer.

  17. Characterisation of retention properties of charge-trapping memory cells at low temperatures

    NASA Astrophysics Data System (ADS)

    Yurchuk, E.; Bollmann, J.; Mikolajick, T.

    2009-09-01

    The density of states of deep level centers in silicon oxynitride layer of SONOS memory cells are calculated from temperature dependent retention measurement. The dominating charge loss mechanisms are direct trap-to-band tunneling (TB) and thermally stimulated emission (TE). Retention measurements at low temperatures (80 - 300K) will be dominated by TE from more "shallow" traps with energies below 1eV and by TB. Taking into account both independent and rival processes the density of states could be calculated self consisting. The results are in excellent agreement with elsewhere published data.

  18. Association between poor clinical prognosis and sleep duration among breast cancer patients.

    PubMed

    Mansano-Schlosser, Thalyta Cristina; Ceolim, Maria Filomena

    2017-06-05

    to investigate the association between clinical progression and the quality and duration of sleep in women with breast cancer. longitudinal study, with 114 participants, conducted in a hospital in Brazil. The instruments used were: questionnaire for sociodemographic and clinical characterization, Pittsburgh Sleep Quality Index; Beck Depression Inventory and Herth Hope Scale. Data were analyzed through descriptive statistics and survival analyses (outcome: poor clinical progression), using the Kaplan-Meier curve, Log-rank test and Cox proportional model. a higher probability of poor clinical progression was verified in women with sleep durations of less than six hours or nine hours and over (p=.0173). the results suggest the importance of further studies that seek to verify whether the quantitative management of sleep disorders would have an impact on the progression of breast cancer. Women should be encouraged to report sleep problems to nurses. mensurar a associação entre evolução clínica e qualidade e duração do sono em mulheres com câncer de mama. estudo longitudinal, com 114 participantes, realizado em um hospital do Brasil. Os instrumentos utilizados foram: questionário para caracterização sociodemográfica e clínica, Índice de Qualidade do Sono de Pittsburgh; Inventário de Depressão de Beck e Escala de Esperança de Herth. Os dados foram analisados via análises descritivas e de sobrevivência (resultado: evolução clínica desfavorável), utilizando-se a curva de Kaplan-Meier, o teste log-rank e o modelo proporcional de Cox. verificou-se maior probabilidade de evolução clínica desfavorável em mulheres com duração de sono inferior a seis ou mais de nove horas (p = 0,0173). os resultados sugerem a importância de mais estudos que buscam verificar se a gestão quantitativa dos distúrbios do sono teria um impacto sobre a evolução do câncer de mama. As mulheres devem ser encorajadas a relatar isso espontaneamente aos enfermeiros. medir

  19. Inertial cavitation to non-invasively trigger and monitor intratumoral release of drug from intravenously delivered liposomes.

    PubMed

    Graham, Susan M; Carlisle, Robert; Choi, James J; Stevenson, Mark; Shah, Apurva R; Myers, Rachel S; Fisher, Kerry; Peregrino, Miriam-Bazan; Seymour, Len; Coussios, Constantin C

    2014-03-28

    The encapsulation of cytotoxic drugs within liposomes enhances pharmacokinetics and allows passive accumulation within tumors. However, liposomes designed to achieve good stability during the delivery phase often have compromised activity at the target site. This problem of inefficient and unpredictable drug release is compounded by the present lack of low-cost, non-invasive methods to measure such release. Here we show that focused ultrasound, used at pressures similar to those applied during diagnostic ultrasound scanning, can be utilised to both trigger and monitor release of payload from liposomes. Notably, drug release was influenced by liposome composition and the presence of SonoVue® microbubbles, which provided the nuclei for the initiation of an event known as inertial cavitation. In vitro studies demonstrated that liposomes formulated with a high proportion of 1,2 distearoyl-sn-glycero-3-phosphoethanolamine (DSPE) released up to 30% of payload following ultrasound exposure in the presence of SonoVue®, provided that the exposure created sufficient inertial cavitation events, as characterised by violent bubble collapse and the generation of broadband acoustic emissions. In contrast a 'Doxil'-like liposome formulation gave no such triggered release. In pre-clinical studies, ultrasound was used as a non-invasive, targeted stimulus to trigger a 16-fold increase in the level of payload release within tumors following intravenous delivery. The inertial cavitation events driving this release could be measured remotely in real-time and were a reliable predictor of drug release. Copyright © 2013 The Authors. Published by Elsevier B.V. All rights reserved.

  20. Lateral spread of heat during thyroidectomy using different haemostatic devices.

    PubMed

    Adamczewski, Zbigniew; Król, Aleksander; Kałużna-Markowska, Karolina; Brzeziński, Jan; Lewiński, Andrzej; Dedecjus, Marek

    2015-01-01

    The presented study is an attempt to comprehensively analyze the lateral spread of heat during thyroidectomy. Obtained results may be valuable in other surgical disciplines in which thermal analysis is difficult or impossible. The aim of the study was to evaluate the temperature distribution in the operating field during thyroidectomy performed with the use of modern haemostatic instruments, and to define the safety margin for the investigated devices. Ninety-three patients were thyroidectomised due to thyroid neoplasm. During all the operations the thermovisual measurements were carried out along with continuous intraoperative neuromonitoring of the recurrent laryngeal nerve (CIONM). Investigated patients were divided into 5 groups, named according to the applied haemostatic technique: LigaSure (N=17); ThermoStapler (N=20); Focus (N=19); SonoSurg (N=17) and Monopolar (N=20). At maximal performance settings, the highest working temperature was observed for the ThermoStapler, while the lowest temperature was recorded for the Monopolar. Safety margin and working time were increased in Focus and SonoSurg, compared to LigaSure and ThermoStapler. The differences in the necrosis thickness were negligible. The largest distance of the midline of the active blade from isotherm of 42ºC observed in the study was 5.51 mm; none of investigated devices used at a bigger distance had influence on the morphology of the electric signal of CIONM. The thermo-visual camera allows non-invasive, safe, and real-time monitoring and analysis of temperature distribution in the operation area during thyroidectomy. Proposed minimal safety margin for the analysed devices is 5.51 mm.

  1. Localized corrosion of 316L stainless steel with SiO2-CaO films obtained by means of sol-gel treatment.

    PubMed

    Vallet-Regí, M; Izquierdo-Barba, I; Gil, F J

    2003-11-01

    Sol-gel films on austenitic stainless steel (AISI 316L) polished wafer were prepared from sono-sols obtained from tetraethylorthosilane and hydrated calcium nitrate. However, pitting was observed in different places on the stainless steel surfaces. The corrosion resistance was evaluated by the polarization resistance in simulated body fluid environment at 37 degrees C. The critical current density, the passive current density, the corrosion potential, and the critical pitting potential were studied. The austenitic stainless steel 316L treated presents important electrochemical corrosion and consequently its application as endosseous implants is not possible. Copyright 2003 Wiley Periodicals, Inc.

  2. Ultrasound (US), Ultraviolet light (UV) and combination (US+UV) assisted semiconductor catalysed degradation of organic pollutants in water: oscillation in the concentration of hydrogen peroxide formed in situ.

    PubMed

    Jyothi, K P; Yesodharan, Suguna; Yesodharan, E P

    2014-09-01

    Application of Advanced Oxidation Processes (AOP) such as sono, photo and sonophoto catalysis in the purification of polluted water under ambient conditions involve the formation and participation of Reactive Oxygen Species (ROS) like ·OH, HO2·, O2(-), H2O2 etc. Among these, H2O2 is the most stable and is also a precursor for the reactive free radicals. Current investigations on the ZnO mediated sono, photo and sonophoto catalytic degradation of phenol pollutant in water reveal that H2O2 formed in situ cannot be quantitatively correlated with the degradation of the pollutant. The concentration of H2O2 formed does not increase corresponding to phenol degradation and reaches a plateau or varies in a wave-like fashion (oscillation) with well defined crests and troughs, indicating concurrent formation and decomposition. The concentration at which decomposition overtakes formation or formation overtakes decomposition is sensitive to the reaction conditions. Direct photolysis of H2O2 in the absence of catalyst or the presence of pre-equilibrated (with the adsorption of H2O2) catalyst in the absence of light does not lead to the oscillation. The phenomenon is more pronounced in sonocatalysis, the intensity of oscillation being in the order sonocatalysis>photocatalysis⩾sonophotocatalysis while the degradation of phenol follows the order sonophotocatalysis>photocatalysis>sonocatalysis>sonolysis>photolysis. In the case of sonocatalysis, the oscillation continues for some more time after discontinuing the US irradiation indicating that the reactive free radicals as well as the trapped electrons and holes which interact with H2O2 have longer life time (memory effect). Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Meningococco B: controllo di due focolai epidemici mediante vaccinazione

    PubMed Central

    2014-01-01

    Riassunto La problematica di un efficace approccio vaccinale nei confronti del Meningococco B (MenB) è stata superata identificando con la metodica della "reverse vaccinology" alcuni antigeni capaci di indurre una risposta verso la maggior parte dei ceppi di MenB circolanti nel mondo. Il nuovo vaccino MenB a 4 componenti (4CMenB) è stato autorizzato in Europa, Australia e Canada, ed è entrato nei calendari di immunizzazione pediatrica internazionali: Australia, Canada, UK. In Italia, le prime regioni che hanno raccomandato la vaccinazione contro il MenB sono state Basilicata e Puglia. La gestione di epidemie/focolai epidemici richiede la messa in atto di una risposta rapida da parte delle autorità sanitarie nei confronti di una emergenza sanitaria ad elevato impatto, anche emotivo, sulla popolazione, come recentemente dimostrato in due università americane. Alla dichiarazione di focolaio epidemico in atto, in entrambi i contesti si è attivata una procedura per l'uso del vaccino 4CMenB non ancora autorizzato negli USA. È stato così possibile organizzare gli interventi di profilassi attiva nei due campus universitari, adottando il primo impiego su larga scala del nuovo vaccino 4CMenB e conseguendo, in tempi relativamente brevi, elevati tassi di copertura vaccinale. A fronte di circa 14000 studenti immunizzati con almeno una dose, non è stata segnalata alcuna problematica di eventi avversi conseguenti all'immunizzazione; ad oggi non si sono verificati casi nei soggetti che hanno ricevuto il vaccino. Come conseguenza dei due focolai descritti, è oggi in corso la valutazione da parte dell'FDA per l'estensione dell'uso del vaccino 4CMenB negli Stati Uniti negli adolescenti e giovani adulti. PMID:25916017

  4. Sonochemical coating of textile fabrics with antibacterial nanoparticles

    NASA Astrophysics Data System (ADS)

    Beddow, Jamie; Singh, Gagandeep; Blanes, María; Molla, Korina; Perelshtein, Ilana; Gedanken, Aharon; Joyce, Eadaoin; Mason, Timothy

    2012-05-01

    The high incidence of hospital-acquired infections places a huge financial burden on our healthcare systems. These infections are also responsible for many millions of deaths each year. Antibacterial fabrics for use in medical textiles, such as hospital uniforms, bedding and wound dressings, can provide a useful weapon in the on-going fight against these infections. The aim of this EU funded Framework 7 project is to develop a pilot line sonochemical coating machine for the production of antibacterial fabrics. The sonochemical coating technology under development is based on a lab scale process that was developed at Bar-Ilan University (BIU). It involves two processes that are driven by acoustic cavitation; the in situ generation of the metal oxide (MO) nanoparticles and the simultaneous high velocity propulsion of these nanoparticles onto a fabric leading to impregnation. Here we report on a comparison of 2 different MO nanoparticle coatings, ZnO and CuO, that were sonochemically applied on to a plain cotton fabric. Both of these coatings were prepared by BIU. In this work, the antibacterial efficacy of the coated fabrics was quantitatively assessed using the absorption method from BS EN ISO 20743:2007. Both types of metal oxide nanoparticle displayed antibacterial activity against all of the test bacteria with particularly high levels of bacterial reduction observed with the CuO coating. The results presented here are from an EU Framework 7 funded project (SONO, EU Project Number: 228730). The project is a collaboration between 17 partner organizations from 10 different European countries. Further details can be found on the project website at: www.fp7-sono.eu.

  5. Acute effects of sono-activated photocatalytic titanium dioxide nanoparticles on oral squamous cell carcinoma.

    PubMed

    Moosavi Nejad, S; Takahashi, Hiromasa; Hosseini, Hamid; Watanabe, Akiko; Endo, Hitomi; Narihira, Kyoichi; Kikuta, Toshihiro; Tachibana, Katsuro

    2016-09-01

    Sonodynamic therapy (SDT) is a new treatment modality using ultrasound to activate certain chemical sensitizers for cancer therapy. In this study, effects of high intensity focused ultrasound (HIFU) combined with photocatalytic titanium dioxide (TiO2) nanoparticles on human oral squamous cell line HSC-2 were investigated. Viability of HSC-2 cells after 0, 0.1, 1, or 3s of HIFU irradiation with 20, 32, 55 and 73Wcm(-2) intensities in the presence or absence of TiO2 was measured immediately after the exposures in vitro. Immediate effects of HIFU (3s, 73Wcm(-2)) combined with TiO2 on solid tumors were also examined by histological study. Cytotoxic effect of HIFU+TiO2in vitro was significantly higher than that of TiO2 or HIFU alone with the tendency to increase for higher HIFU intensity, duration, and TiO2 concentration in the suspension. In vivo results showed significant necrosis and tissue damage in HIFU and HIFU+TiO2 treated samples. However, penetration of TiO2 nanoparticles into the cell cytoplasm was only observed in HIFU+TiO2 treated tissues. In this study, our findings provide a rational basis for the development of an effective HIFU based sonodynamic activation method. This approach offers an attractive non-invasive therapy technique for oral cancer in future. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Sono-assisted extraction of alcohol-insoluble extract from Althaea rosea: purification and chemical analysis.

    PubMed

    Eskandari, Meghdad; Samavati, Vahid

    2015-01-01

    A Box-Behnken design (BBD) was used to evaluate the effects of ultrasonic power, extraction time, extraction temperature, and water to raw material ratio on extraction yield of alcohol-insoluble polysaccharide of Althaea rosea leaf (ARLP). Purification was carried out by dialysis method. Chemical analysis of ARLP revealed contained 12.69 ± 0.48% moisture, 79.33 ± 0.51% total sugar, 3.82 ± 0.21% protein, 11.25 ± 0.37% uronic acid and 3.77 ± 0.15% ash. The response surface methodology (RSM) showed that the significant quadratic regression equation with high R(2) (=0.9997) was successfully fitted for extraction yield of ARLP as function of independent variables. The overall optimum region was found to be at the combined level of ultrasonic power 91.85 W, extraction time 29.94 min, extraction temperature 89.78 °C, and the ratio of water to raw material 28.77 (mL/g). At this optimum point, extraction yield of ARLP was 19.47 ± 0.41%. No significant (p>0.05) difference was found between the actual and predicted (19.30 ± 0.075%) values. The results demonstrated that ARLP had strong scavenging activities on DPPH and hydroxyl radicals. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Chirp resonance spectroscopy of single lipid-coated microbubbles using an "acoustical camera".

    PubMed

    Renaud, G; Bosch, J G; van der Steen, A F W; de Jong, N

    2012-12-01

    An acoustical method was developed to study the resonance of single lipid-coated microbubbles. The response of 127 SonoVue microbubbles to a swept sine excitation between 0.5 and 5.5 MHz with a peak acoustic pressure amplitude of 70 kPa was measured by means of a 25 MHz probing wave. The relative amplitude modulation in the signal scattered in response to the probing wave is approximately equal to the radial strain induced by the swept sine excitation. An average damping coefficient of 0.33 and an average resonance frequency of 2.5 MHz were measured. Microbubbles experienced an average peak radial strain of 20%.

  8. EUS Needle Identification Comparison and Evaluation study (with videos).

    PubMed

    Tang, Shou-Jiang; Vilmann, Andreas S; Saftoiu, Adrian; Wang, Wanmei; Streba, Costin Teodor; Fink, Peter P; Griswold, Michael; Wu, Ruonan; Dietrich, Christoph F; Jenssen, Christian; Hocke, Michael; Kantowski, Marcus; Pohl, Jürgen; Fockens, Paul; Annema, Jouke T; van der Heijden, Erik H F M; Havre, Roald Flesland; Pham, Khanh Do-Cong; Kunda, Rastislav; Deprez, Pierre H; Mariana, Jinga; Vazquez-Sequeiros, Enrique; Larghi, Alberto; Buscarini, Elisabetta; Fusaroli, Pietro; Lahav, Maor; Puri, Rajesh; Garg, Pramod Kumar; Sharma, Malay; Maluf-Filho, Fauze; Sahai, Anand; Brugge, William R; Lee, Linda S; Aslanian, Harry R; Wang, Andrew Y; Shami, Vanessa M; Markowitz, Arnold; Siddiqui, Ali A; Mishra, Girish; Scheiman, James M; Isenberg, Gerard; Siddiqui, Uzma D; Shah, Raj J; Buxbaum, James; Watson, Rabindra R; Willingham, Field F; Bhutani, Manoop S; Levy, Michael J; Harris, Cynthia; Wallace, Michael B; Nolsøe, Christian Pállson; Lorentzen, Torben; Bang, Niels; Sørensen, Sten Mellerup; Gilja, Odd Helge; D'Onofrio, Mirko; Piscaglia, Fabio; Gritzmann, Norbert; Radzina, Maija; Sparchez, Zeno Adrian; Sidhu, Paul S; Freeman, Simon; McCowan, Timothy C; de Araujo, Cyrillo Rodrigues; Patel, Akash; Ali, Mohammad Adel; Campbell, Garth; Chen, Edward; Vilmann, Peter

    2016-09-01

    EUS-guided FNA or biopsy sampling is widely practiced. Optimal sonographic visualization of the needle is critical for image-guided interventions. Of the several commercially available needles, bench-top testing and direct comparison of these needles have not been done to reveal their inherent echogenicity. The aims are to provide bench-top data that can be used to guide clinical applications and to promote future device research and development. Descriptive bench-top testing and comparison of 8 commonly used EUS-FNA needles (all size 22 gauge): SonoTip Pro Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition (Cook Medical); ClearView (Conmed); EZ Shot 2 (Olympus); and BNX (Beacon Endoscopic), and 2 new prototype needles, SonoCoat (Medi-Globe), coated by echogenic polymers made by Encapson. Blinded evaluation of standardized and unedited videos by 43 EUS endoscopists and 17 radiologists specialized in GI US examination who were unfamiliar with EUS needle devices. There was no significant difference in the ratings and rankings of these needles between endosonographers and radiologists. Overall, 1 prototype needle was rated as the best, ranking 10% to 40% higher than all other needles (P < .01). Among the commercially available needles, the EchoTip Ultra needle and the ClearView needle were top choices. The EZ Shot 2 needle was ranked statistically lower than other needles (30%-75% worse, P < .001). All FNA needles have their inherent and different echogenicities, and these differences are similarly recognized by EUS endoscopists and radiologists. Needles with polymeric coating from the entire shaft to the needle tip may offer better echogenicity. Copyright © 2016 American Society for Gastrointestinal Endoscopy. All rights reserved.

  9. [Levels of trace elements in the fruits and vegetables from the so-called Land of fires in Campania Region (Southern Italy)].

    PubMed

    Esposito, Mauro; Cavallo, Stefania; Rosato, Guido; Chiaravalle, Eugenio; Miedico, Oto; Pellicanò, Roberta; Soprano, Vittorio; Baldi, Loredana

    2016-01-01

    INTRODUZIONE: una vasta area compresa tra le province di Napoli e Caserta nella regione Campania ha negli ultimi anni attirato l'attenzione dei mass media a causa degli interramenti illeciti di rifiuti di varia origine nei campi o del loro abbandono lungo le strade. A tali pratiche illecite si aggiunge il fenomeno dei roghi incontrollati di questo materiale, motivo per il quale la zona è stata soprannominata "Terra dei fuochi". OBIETTIVI: ricerca di elementi in tracce presenti nei prodotti alimentari di origine vegetale prodotti nella Terra dei fuochi. DISEGNO E SETTING: piano di monitoraggio per il rilevamento dei livelli di alcuni metalli tossici ed essenziali nei vegetali coltivati in Campania nella Terra dei fuochi. La determinazione dei microelementi è stata effettuata dopo mineralizzazione della sostanza organica mediante microonde, utilizzando la spettrometria di massa a plasma induttivamente accoppiato (ICP-MS). RISULTATI: durante l'attività di monitoraggio sono stati raccolti 65 campioni di ortaggi e 49 campioni di frutta in 43 comuni rientranti nella Terra dei fuochi. Il contenuto medio di metalli tossici, cadmio e piombo nei prodotti ortofrutticoli è risultato ben lontano dai limiti massimi fissati dalla normativa europea. I valori delle concentrazioni sono significativamente inferiori rispetto a quanto riscontrato in zone ad alto impatto ambientale a causa della presenza di impianti industriali. CONCLUSIONI: la presenza di elementi tossici o potenzialmente tali nei campioni vegetali prodotti nella Terra dei fuochi è attribuibile a una varietà di fattori ambientali rilevanti (caratteristiche geologiche dell'area, inquinamento del suolo, dell'atmosfera e delle acque di irrigazione, pratiche illecite di smaltimento dei rifiuti industriali); non sembra, tuttavia, sussistere un rischio per la salute dei consumatori. Resta comunque l'allerta per la loro presenza nell'ambiente e la necessità che le attività di monitoraggio continuino.

  10. Non-pharmacological interventions to promote the sleep of patients after cardiac surgery: a systematic review.

    PubMed

    Machado, Fernanda de Souza; Souza, Regina Claudia da Silva; Poveda, Vanessa Brito; Costa, Ana Lucia Siqueira

    2017-09-12

    to analyze evidence available in the literature concerning non-pharmacological interventions that are effective to treat altered sleep patterns among patients who underwent cardiac surgery. systematic review conducted in the National Library of Medicine-National Institutes of Health, Cochrane Central Register of Controlled Trials, Latin American and Caribbean Health Sciences Literature, Scopus, Embase, Cumulative Index to Nursing and Allied Health Literature and PsycINFO databases, and also grey literature. ten controlled, randomized clinical trials were included in this review. Non-pharmacological interventions were grouped into three main categories, namely: relaxation techniques, devices or equipment to minimize sleep interruptions and/or induce sleep, and educational strategies. Significant improvement was found in the scores assessing sleep quality among studies testing interventions such as earplugs, sleeping masks, muscle relaxation, posture and relaxation training, white noise, and educational strategies. In regard to the studies' methodological quality, high quality studies as established by Jadad scoring were not found. significant improvement was found among the scores assessing sleep in the studies testing interventions such as earplugs, sleeping masks, muscle relaxation, posture and relaxation training, white noise and music, and educational strategies. analisar as evidências disponíveis, na literatura, sobre as intervenções não farmacológicas, efetivas para o tratamento da alteração do padrão do sono em pacientes submetidos à cirurgia cardíaca. revisão sistemática realizada por meio de busca nas bases de dados National Library of Medicine National Institutes of Health, Cochrane Central Register of Controlled Trials, Literatura Latino-Americana e do Caribe em Ciências da Saúde, Scopus, Embase, Cumulative Index to Nursing and Allied Health Literature e PsycINFO, e na literatura cinzenta. dez ensaios clínicos controlados e randomizados

  11. SonoNet: Real-Time Detection and Localisation of Fetal Standard Scan Planes in Freehand Ultrasound.

    PubMed

    Baumgartner, Christian F; Kamnitsas, Konstantinos; Matthew, Jacqueline; Fletcher, Tara P; Smith, Sandra; Koch, Lisa M; Kainz, Bernhard; Rueckert, Daniel

    2017-11-01

    Identifying and interpreting fetal standard scan planes during 2-D ultrasound mid-pregnancy examinations are highly complex tasks, which require years of training. Apart from guiding the probe to the correct location, it can be equally difficult for a non-expert to identify relevant structures within the image. Automatic image processing can provide tools to help experienced as well as inexperienced operators with these tasks. In this paper, we propose a novel method based on convolutional neural networks, which can automatically detect 13 fetal standard views in freehand 2-D ultrasound data as well as provide a localization of the fetal structures via a bounding box. An important contribution is that the network learns to localize the target anatomy using weak supervision based on image-level labels only. The network architecture is designed to operate in real-time while providing optimal output for the localization task. We present results for real-time annotation, retrospective frame retrieval from saved videos, and localization on a very large and challenging dataset consisting of images and video recordings of full clinical anomaly screenings. We found that the proposed method achieved an average F1-score of 0.798 in a realistic classification experiment modeling real-time detection, and obtained a 90.09% accuracy for retrospective frame retrieval. Moreover, an accuracy of 77.8% was achieved on the localization task.

  12. Removal of reactive blue 19 dye by sono, photo and sonophotocatalytic oxidation using visible light.

    PubMed

    Khan, Muhammad Abdul Nasir; Siddique, Maria; Wahid, Fazli; Khan, Romana

    2015-09-01

    An efficient sonophotocatalytic degradation of reactive blue 19 (RB 19) dye was successfully carried out using sulfur-doped TiO2 (S-TiO2) nanoparticles. The effect of various treatment processes that is sonolysis, photolysis, catalysis, sonocatalysis, photocatalysis, and sonophotocatalysis were investigated for RB 19 removal. S-TiO2 were synthesized in 1, 3 and 5 wt.% of sulfur by sol-gel process and characterized by X-ray diffraction (XRD) and scanning electron microscopy coupled with energy dispersive X-ray (SEM-EDX), UV-Visible diffuse reflectance spectra (DRS). The results confirm anatase phase of TiO2, porous agglomerate structure, and a red shift in the absorbance spectra of S-TiO2. The dye degradation was studied by using UV-Vis spectrophotometer at λ max=594 nm. The reaction parameters such as pH, catalyst dosage, initial dye concentration, ultrasonic power and effect of sulfur doping in different weight percent were studied to find out the optimum degradation conditions. Optimum conditions were found as: S-TiO2=5 wt.%, catalyst (S-TiO2 5 wt.%)=50mg, RB 19 solution concentration=20 mg L(-1), pH=3, ultrasound power=100 and operating temperature=25°C. The response of 5 wt.% S-TiO2 was found better than 1 and 3 wt.% S-TiO2 and other forms TiO2. The sonophotocatalysis process was superior to other methods. During this process the ultrasound cavitation and photocatalysis water splitting takes place which leads to the generation of OH. As reveled by the GCMS results the reactive blue 19 (20 mg L(-1)) was degraded to 90% within 120 min. The S-TiO2 sonophotocatalysis system was studied for the first time for dye degradation and was found practicable, efficient and cost effective for the degradation of complex and resistant dyes such as RB19. Copyright © 2015. Published by Elsevier B.V.

  13. Results from On-Orbit Testing of the Fram Memory Test Experiment on the Fastsat Micro-Satellite

    NASA Technical Reports Server (NTRS)

    MacLeod, Todd C.; Sims, W. Herb; Varnavas, Kosta A.; Ho, Fat D.

    2011-01-01

    NASA is planning on going beyond Low Earth orbit with manned exploration missions. The radiation environment for most Low Earth orbit missions is harsher than at the Earth's surface but much less harsh than deep space. Development of new electronics is needed to meet the requirements of high performance, radiation tolerance, and reliability. The need for both Volatile and Non-volatile memory has been identified. Emerging Non-volatile memory technologies (FRAM, C-RAM,M-RAM, R-RAM, Radiation Tolerant FLASH, SONOS, etc.) need to be investigated for use in Space missions. An opportunity arose to fly a small memory experiment on a high inclination satellite (FASTSAT). An off-the-shelf 512K Ramtron FRAM was chosen to be tested in the experiment.

  14. The role of physical exercise in obstructive sleep apnea.

    PubMed

    Andrade, Flávio Maciel Dias de; Pedrosa, Rodrigo Pinto

    2016-01-01

    Obstructive sleep apnea (OSA) is a common clinical condition, with a variable and underestimated prevalence. OSA is the main condition associated with secondary systemic arterial hypertension, as well as with atrial fibrillation, stroke, and coronary artery disease, greatly increasing cardiovascular morbidity and mortality. Treatment with continuous positive airway pressure is not tolerated by all OSA patients and is often not suitable in cases of mild OSA. Hence, alternative methods to treat OSA and its cardiovascular consequences are needed. In OSA patients, regular physical exercise has beneficial effects other than weight loss, although the mechanisms of those effects remain unclear. In this population, physiological adaptations due to physical exercise include increases in upper airway dilator muscle tone and in slow-wave sleep time; and decreases in fluid accumulation in the neck, systemic inflammatory response, and body weight. The major benefits of exercise programs for OSA patients include reducing the severity of the condition and daytime sleepiness, as well as increasing sleep efficiency and maximum oxygen consumption. There are few studies that evaluated the role of physical exercise alone for OSA treatment, and their protocols are quite diverse. However, aerobic exercise, alone or combined with resistance training, is a common point among the studies. In this review, the major studies and mechanisms involved in OSA treatment by means of physical exercise are presented. In addition to systemic clinical benefits provided by physical exercise, OSA patients involved in a regular, predominantly aerobic, exercise program have shown a reduction in disease severity and in daytime sleepiness, as well as an increase in sleep efficiency and in peak oxygen consumption, regardless of weight loss. RESUMO A apneia obstrutiva do sono (AOS) é uma condição clínica comum, possuindo prevalência variável e subestimada. Principal condição associada à hipertens

  15. High stable suspension of magnetite nanoparticles in ethanol by using sono-synthesized nanomagnetite in polyol medium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bastami, Tahereh Rohani; Entezari, Mohammad H., E-mail: moh_entezari@yahoo.com

    2013-09-01

    Graphical abstract: - Highlights: • The sonochemical synthesis of magnetite nanoparticles was carried out in EG without any surfactant. • The nanoparticles with sizes ∼24 nm were composed of small building blocks with sizes ∼2 nm. • The hydrophilic magnetite nanoparticles were stable in ethanol even after 8 months. • Ultrasonic intensity showed a crucial role on the obtained high stable magnetite nanoparticles in ethanol. - Abstract: The sonochemical synthesis of magnetite nanoparticles was carried out at relatively low temperature (80 °C) in ethylene glycol (EG) as a polyol solvent. The particle size was determined by transmission electron microscopy (TEM).more » The magnetite nanoparticles with an average size of 24 nm were composed of small building blocks with an average size of 2–3 nm and the particles exhibited nearly spherical shape. The surface characterization was investigated by using Fourier transform infrared (FTIR) spectroscopy, X-ray photoelectron spectroscopy (XPS), and thermogravimetric analysis (TGA). The stability of magnetite nanoparticles was studied in ethanol as a polar solvent. The nanoparticles showed an enhanced stability in ethanol which is due to the hydrophilic surface of the particles. The colloidal stability of magnetite nanoparticles in ethanol was monitored by UV–visible spectrophotometer. According to the results, the nanoparticles synthesized in 30 min of sonication with intensity of 35 W/cm{sup 2} (50%) led to a maximum stability in ethanol as a polar solvent with respect to the other applied intensities. The obtained magnetite nanoparticles were stable for more than12 months.« less

  16. Sono-activated persulfate oxidation of diclofenac: Degradation, kinetics, pathway and contribution of the different radicals involved.

    PubMed

    Monteagudo, J M; El-Taliawy, H; Durán, A; Caro, G; Bester, K

    2018-06-20

    Degradation of a diclofenac aqueous solution was performed using persulfate anions activated by ultrasound. The objective of this study was to analyze different parameters affecting the diclofenac (DCF) removal reaction by the ultrasonic persulfate (US/PS) process and to evaluate the role played by various intermediate oxidative species such as hydroxyl- and sulfate radicals, superoxide radical anion or singlet oxygen in the removal process as well as to determine a possible reaction pathway. The effects of pH, initial persulfate anion concentration, ultrasonic amplitude and temperature on DCF degradation were examined. Sulfate and hydroxyl radicals were involved in the main reaction pathway of diclofenac. Diclofenac amide and three hydroxy-diclofenac isomers (3´-hydroxy diclofenac, 4´-hydroxy diclofenac and 5-hydroxy diclofenac) were identified as reaction intermediates. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Preparation of nanobubbles carrying androgen receptor siRNA and their inhibitory effects on androgen-independent prostate cancer when combined with ultrasonic irradiation.

    PubMed

    Wang, Luofu; Zhang, Miao; Tan, Kaibin; Guo, Yanli; Tong, Haipeng; Fan, Xiaozhou; Fang, Kejing; Li, Rui

    2014-01-01

    The objective of this study was to investigate nanobubbles carrying androgen receptor (AR) siRNA and their in vitro and in vivo anti-tumor effects, when combined with ultrasonic irradiation, on androgen-independent prostate cancer (AIPC). Nanobubbles carrying AR siRNA were prepared using poly-L-lysine and electrostatic adsorption methods. Using C4-2 cell activity as a testing index, the optimal irradiation parameters (including the nanobubble number/cell number ratio, mechanical index [MI], and irradiation time) were determined and used for transfection of three human prostate cancer cell lines (C4-2, LNCaP, and PC-3 cells). The AR expression levels were investigated with RT-PCR and Western blot analysis. Additionally, the effects of the nanobubbles and control microbubbles named SonoVue were assessed via imaging in a C4-2 xenograft model. Finally, the growth and AR expression of seven groups of tumor tissues were assessed using the C4-2 xenograft mouse model. The nanobubbles had an average diameter of 609.5±15.6 nm and could effectively bind to AR siRNA. Under the optimized conditions of a nanobubble number/cell number ratio of 100∶1, an MI of 1.2, and an irradiation time of 2 min, the highest transfection rates in C4-2, LNCaP, and PC-3 cells were 67.4%, 74.0%, and 63.96%, respectively. In the C4-2 and LNCaP cells, treatment with these binding nanobubbles plus ultrasonic irradiation significantly inhibited cell growth and resulted in the suppression of AR mRNA and protein expression. Additionally, contrast-enhanced ultrasound showed that the nanobubbles achieved stronger signals than the SonoVue control in the central hypovascular area of the tumors. Finally, the anti-tumor effect of these nanobubbles plus ultrasonic irradiation was most significant in the xenograft tumor model compared with the other groups. Nanobubbles carrying AR siRNA could be potentially used as gene vectors in combination with ultrasonic irradiation for the treatment of AIPC.

  18. Preparation of Nanobubbles Carrying Androgen Receptor siRNA and Their Inhibitory Effects on Androgen-Independent Prostate Cancer when Combined with Ultrasonic Irradiation

    PubMed Central

    Tan, Kaibin; Guo, Yanli; Tong, Haipeng; Fan, Xiaozhou; Fang, Kejing; Li, Rui

    2014-01-01

    Objective The objective of this study was to investigate nanobubbles carrying androgen receptor (AR) siRNA and their in vitro and in vivo anti-tumor effects, when combined with ultrasonic irradiation, on androgen-independent prostate cancer (AIPC). Materials and Methods Nanobubbles carrying AR siRNA were prepared using poly-L-lysine and electrostatic adsorption methods. Using C4-2 cell activity as a testing index, the optimal irradiation parameters (including the nanobubble number/cell number ratio, mechanical index [MI], and irradiation time) were determined and used for transfection of three human prostate cancer cell lines (C4-2, LNCaP, and PC-3 cells). The AR expression levels were investigated with RT-PCR and Western blot analysis. Additionally, the effects of the nanobubbles and control microbubbles named SonoVue were assessed via imaging in a C4-2 xenograft model. Finally, the growth and AR expression of seven groups of tumor tissues were assessed using the C4-2 xenograft mouse model. Results The nanobubbles had an average diameter of 609.5±15.6 nm and could effectively bind to AR siRNA. Under the optimized conditions of a nanobubble number/cell number ratio of 100∶1, an MI of 1.2, and an irradiation time of 2 min, the highest transfection rates in C4-2, LNCaP, and PC-3 cells were 67.4%, 74.0%, and 63.96%, respectively. In the C4-2 and LNCaP cells, treatment with these binding nanobubbles plus ultrasonic irradiation significantly inhibited cell growth and resulted in the suppression of AR mRNA and protein expression. Additionally, contrast-enhanced ultrasound showed that the nanobubbles achieved stronger signals than the SonoVue control in the central hypovascular area of the tumors. Finally, the anti-tumor effect of these nanobubbles plus ultrasonic irradiation was most significant in the xenograft tumor model compared with the other groups. Conclusion Nanobubbles carrying AR siRNA could be potentially used as gene vectors in combination with ultrasonic

  19. Comparison of conventional versus three-dimensional ultrasound in fetal renal pelvis measurement and their potential prediction of neonatal uropathies.

    PubMed

    Duin, L K; Nijhuis, J G; Scherjon, S A; Vossen, M; Willekes, C

    2016-01-01

    To establish a threshold value for fetal renal pelvis dilatation measured by automatic volume calculation (SonoAVC) in the third trimester of pregnancy to predict neonatal uropathies, and to compare these results with conventional antero-posterior (AP) measurement, fetal kidney 3D volume and renal parenchymal thickness. In a prospective cohort study, 125 fetuses with renal pelvis AP diameter of ≥5 mm both at 20 weeks of gestation and in the third trimester, underwent an additional 3D volume measurement of the fetal kidney in the third trimester. Receiver operating characteristic (ROC) curves for establishing threshold values for fetal renal pelvis volume, AP measurement, fetal kidney volume and renal parenchymal thickness to predict neonatal uropathies were analyzed. Also, sensitivity, specificity, area under the curve (AUC) and likelihood ratios were calculated. A cut-off point of 1.58 cm³ was identified in the third trimester of pregnancy (AUC 0.865 (95% CI 0.789-0.940), sensitivity 76.3%, specificity 87.4%, LR+ 6.06, LR- 0.27) for measurements with SonoAVC. A cut-off value of 11.5 mm was established in the third trimester of pregnancy (AUC 0.828 (95% CI 0.737-0.918), sensitivity 71.1%, specificity 85.1%, LR+ 4.77, LR- 0.34) for the conventional AP measurement. A cut-off point for fetal kidney volume was calculated at 13.29 cm³ (AUC 0.769 (95% CI 0.657-0.881), sensitivity 71%, specificity 66%, LR+ 2.09, LR- 0.44). For renal parenchymal thickness, a cut-off point of 8.4 mm was established (AUC 0.216 (95% CI 0.117-0.315), sensitivity 31.6%, specificity 32.6%, LR+ 0.47, LR- 2.10). This study demonstrates that 3D fetal renal pelvis volume measurements and AP measurements both have a good and comparable diagnostic performance, fetal renal volume a fair accuracy and renal parenchymal thickness a poor accuracy in predicting postnatal renal outcome.

  20. [Assessment of a project for integrated management of care given to patients with type-2 diabetes in the Local Health Authority 21 of Legnago (Veneto Region, Northern Italy) in the period 2010-2012].

    PubMed

    Marcon, Alessandro; Vaona, Alberto; Rigon, Giulio; Carazzolo, Marco; Del Zotti, Franco; Girotto, Sandro; Marafetti, Claudio

    2016-01-01

    OBIETTIVI: descrivere, nella ASL 21 di Legnago (VR), l'andamento di alcuni indicatori sanitari tra il 2009, anno precedente all'avvio di un progetto triennale per la gestione integrata dell'assistenza al paziente con diabete mellito di tipo 2, e il 2012, ultimo anno del progetto. DISEGNO: studio longitudinale trasversale ripetuto. SETTING E PARTECIPANTI: tutti i pazienti diabetici di tipo 2 della ASL 21, identificati nei database aziendali (in base a esenzioni per patologia, accessi al servizio diabetologico, consumo di farmaci antidiabetici e strisce per la determinazione della glicemia) e nelle cartelle cliniche dei medici di famiglia. PRINCIPALI MISURE DI OUTCOME: numero di test diagnostici e di follow-up erogati, consumo di farmaci, prestazioni specialistiche, accessi al pronto soccorso, ricoveri e mortalità. RISULTATI: nonostante un calo generalizzato (-3,1%) nei test erogati dalla ASL 21 ai suoi assistititi nel periodo 2009-2012, l'analisi ha documentato un marcato aumento per gli esami previsti nella gestione del diabete, quali curve da carico glicemico (+104,3%), emoglobina glicata (+19,0%) e microalbuminuria (+296,1%). I soggetti identificati come diabetici sono aumentati da 8.084 nel 2009 (5,2%) a 9.221 nel 2012 (5,9%). Sono stati osservati aumenti nella prevalenza di pazienti visitati presso un servizio diabetologico (dal 22,6% al 39,0%), nonché negli utilizzatori di metformina (dal 28,0% al 37,5%), insuline (dal 13,5% al 18,3%) e incretine (dall'1,4% al 9,0%). Il consumo di sulfaniluree è, invece, calato (dal 49,9% al 40,8%), come anche l'erogazione di alcune prestazioni specialistiche, gli accessi al pronto soccorso e i ricoveri, mentre il tasso di mortalità è rimasto stabile (29,6 decessi x1.000/anno). CONCLUSIONE: durante il periodo di implementazione del progetto sembra essersi verificato un aumento della sensibilità diagnostica e una maggiore presa in carico del paziente diabetico. Anche se la natura osservazionale dello studio non consente

  1. Early fetal heart ultrasonography as additional indicator for chromosomopathies.

    PubMed

    Dmitrovic, A; Jeremic, K; Babic, U M; Perovic, M; Mihailovic, T; Opric, D; Zecevic, N; Gojnić-Dugalić, M

    2016-01-01

    First trial of estimating values of scans of fetal heart structures (FHS) in first trimester of pregnancy, as more primary facts of possible chromosomopathies. The study included 2,643 fetuses that were examined in first trimester of pregnancy on Sono CT convex (C5-2MHz), endovaginal (ev 8-4MHz), and linear transducers (L12-5MHz) during a period of eight years. Fetal heart was evaluated using appropriate software with broad-band transducers and color Doppler, Sono CT, and HD ZOOM technologies. The scan was performed by three experienced physicians. FHS were based on: left and right ventricle morphology; AV valves (atrioventricular) position and existence of primal ostium; relationship of left ventricle outflow tract (LVOT) and right ventricle outflow tract (RVOT) and great vessels on three vessel view (3VV) and estimation of ductal and aortic arch. Several developments, one being the ability to identify fetuses at risk for cardiac defects combining nuchal translucency (NT), ductus venosus (DV) Doppler, and evaluation of tricuspid regurgitation, have prompted reconsideration of the role of the first trimester prognostic factor of fetal evaluation. In low-risk pregnancies group, 36 (1.8%) fetuses were found to have congenital heart disease (CHD), and in high-risk pregnancies the number of fetuses with CHD was 75 (12%). Genetic amniocentesis or chorionic villus sampling (CVS) was performed in all fetuses with CHD. Forty-two (37.8%) fetuses with CHD were found to have chromosomal anomalies. Out of 111 fetuses with CHD 39 (35.1%) had an nuchal translucency (NT) above three mm. Out of 42 fetuses with chromosomal anomalies and CHD, 29 (69%) had an increased NT. Using first trimester fetal echosonography constitutes a further step in the earlier recognition of chromosomopathies, even in low risk groups. Still further steps are necessary as all facts of good clinical practice. In order to offer further benefits during pregnancies, improvements in diagnostics are still

  2. Satellite and mobile wireless transmission of focused assessment with sonography in trauma.

    PubMed

    Strode, Christofer A; Rubal, Bernard J; Gerhardt, Robert T; Christopher, Frank L; Bulgrin, James R; Kinkler, E Sterling; Bauch, Terry D; Boyd, Sheri Y N

    2003-12-01

    Focused assessment with sonography in trauma (FAST) can define life-threatening injuries in austere settings with remote real-time review by experienced physicians. This study evaluates vest-mounted microwave, satellite, and LifeLink communications technology for image clarity and diagnostic accuracy during remote transmission of FAST examinations. Using a SonoSite, FAST was obtained on three patients with pericardial and intraperitoneal effusions and two control subjects in a remotely located U.S. Army Combat Support Hospital. A miniature vest-mounted video transmitter attached to the SonoSite sent wireless ultrasound video 20 m to a receiving antenna. The signal was then transferred over VSAT satellite systems at 512 kilobaud per second (kbps), INMARSAT satellite systems at 64 kbps, and over LifeLink on a moving ambulance through a metropolitan wireless traffic-management network. Clarity and absence or presence of effusions were recorded by 15 staff emergency physicians. Average sensitivity, specificity, and accuracy were 87% (95% confidence interval [CI]=79% to 95%), 85% (95% CI=81% to 89%), and 86% (95% CI=82% to 90%) for the Premier Wireless Vest; 98% (95% CI=97% to 99%), 83% (95% CI=75% to 91%), and 86% (95% CI=82% to 90%) for VSAT; 95% (95% CI=94% to 96%), 70% (95% CI=58% to 82%), and 75% (95% CI=70% to 80%) for INMARSAT; and 82% (95% CI=73% to 91%), 83% (95% CI=74% to 92%), and 82% (95% CI=78% to 86%) for LifeLink with clarity of 3.0 (95% CI=2.7 to 3.3), 2.9 (95% CI=2.6 to 3.2), 1.3 (95% CI=1.2 to 1.4), and 2.1 (95% CI=1.8 to 2.4), respectively. Accuracy correlated with clarity. Roaming vest transmission of FAST provides interpretable, diagnostic imagery at the distances used in this study. VSAT provided the best clarity and diagnostic value with the lighter, more portable INMARSAT serving a lesser role for remote clinical interpretation. LifeLink performed well, and further infrastructure improvements may increase clarity and accuracy.

  3. Using iPads to Teach Communication Skills of Students with Autism.

    PubMed

    Xin, Joy F; Leonard, Deborah A

    2015-12-01

    The purpose of this study was to examine the effects of using an iPad to assist students with autism in learning communication skills. Three, 10 years old learners diagnosed with autism who present little or no functional speech, participated in the study. A multiple baseline design with AB phases across academic and social settings was used. During the baseline, students were given access to an iPad with the SonoFlex speech-generating device application, while no communicative attempts were observed. During the intervention, the students were taught to use the iPad to communicate with their teacher and peers for 6 weeks. With a least-to-most prompting hierarchy, all students increased initiating requests, responding to questions and making social comments in both class and recess settings.

  4. Tunnel field-effect transistor charge-trapping memory with steep subthreshold slope and large memory window

    NASA Astrophysics Data System (ADS)

    Kino, Hisashi; Fukushima, Takafumi; Tanaka, Tetsu

    2018-04-01

    Charge-trapping memory requires the increase of bit density per cell and a larger memory window for lower-power operation. A tunnel field-effect transistor (TFET) can achieve to increase the bit density per cell owing to its steep subthreshold slope. In addition, a TFET structure has an asymmetric structure, which is promising for achieving a larger memory window. A TFET with the N-type gate shows a higher electric field between the P-type source and the N-type gate edge than the conventional FET structure. This high electric field enables large amounts of charges to be injected into the charge storage layer. In this study, we fabricated silicon-oxide-nitride-oxide-semiconductor (SONOS) memory devices with the TFET structure and observed a steep subthreshold slope and a larger memory window.

  5. How changes in nutrition have influenced the development of allergic diseases in childhood

    PubMed Central

    2012-01-01

    possono prevenire lo sviluppo di respiro sibilante (wheezing) attraverso i loro effetti antiossidanti contengono vitamina C e selenio; i livelli ematici di questi elementi sono correlati negativamente con il rischio di wheezing. Inoltre l'assunzione di vitamina E durante la gravidanza sembra essere correlato con un rischio ridotto di respiro sibilante per il nascituro. Allo stesso modo, basso apporto di zinco e di carotenoidi in donne in gravidanza è associata ad un aumentato rischio di wheezing e asma nell'infanzia. Anche le fibre hanno proprietà anti-infiammatorie ed effetti protettivi contro le malattie allergiche come la dermatite atopica e l’asma. Il consumo di grassi influenza lo sviluppo delle vie aeree. Le popolazioni dei paesi occidentali hanno aumentato il loro consumo di n-6 PUFA e, parallelamente, ridotto n-3 PUFA. Ciò ha portato alla diminuzione della produzione di PGE2, che si ritiene abbia un effetto protettivo contro l'infiammazione delle vie aeree. Ipotesi contrastanti riguardano la vitamina D, sia un eccesso che una carenza di vitamina D, infatti, sono stati associati ad un aumentato rischio di asma. Ulteriori studi sul ruolo di queste sostanze sono necessari prima di trarre conclusioni sul piano clinico. PMID:22651129

  6. 3D gate-all-around bandgap-engineered SONOS flash memory in vertical silicon pillar with metal gate

    NASA Astrophysics Data System (ADS)

    Oh, Jae-Sub; Yang, Seong-Dong; Lee, Sang-Youl; Kim, Young-Su; Kang, Min-Ho; Lim, Sung-Kyu; Lee, Hi-Deok; Lee, Ga-Won

    2013-08-01

    In this paper, a gate-all-around bandgap-engineered silicon-oxide-nitride-oxide-silicon device with a vertical silicon pillar structure and a Ti metal gate are demonstrated for a potential solution to overcome the scaling-down of flash memory device. The devices were fabricated using CMOS-compatible technology and exhibited well-behaved memory characteristics in terms of the program/erase window, retention, and endurance properties. Moreover, the integration of the Ti metal gate demonstrated a significant improvement in the erase characteristics due to the efficient suppression of the electron back tunneling through the blocking oxide.

  7. An FPGA-Based Test-Bed for Reliability and Endurance Characterization of Non-Volatile Memory

    NASA Technical Reports Server (NTRS)

    Rao, Vikram; Patel, Jagdish; Patel, Janak; Namkung, Jeffrey

    2001-01-01

    Memory technologies are divided into two categories. The first category, nonvolatile memories, are traditionally used in read-only or read-mostly applications because of limited write endurance and slow write speed. These memories are derivatives of read only memory (ROM) technology, which includes erasable programmable ROM (EPROM), electrically-erasable programmable ROM (EEPROM), Flash, and more recent ferroelectric non-volatile memory technology. Nonvolatile memories are able to retain data in the absence of power. The second category, volatile memories, are random access memory (RAM) devices including SRAM and DRAM. Writing to these memories is fast and write endurance is unlimited, so they are most often used to store data that change frequently, but they cannot store data in the absence of power. Nonvolatile memory technologies with better future potential are FRAM, Chalcogenide, GMRAM, Tunneling MRAM, and Silicon-Oxide-Nitride-Oxide-Silicon (SONOS) EEPROM.

  8. Targeted nanobubbles in low-frequency ultrasound-mediated gene transfection and growth inhibition of hepatocellular carcinoma cells.

    PubMed

    Wu, Bolin; Qiao, Qiang; Han, Xue; Jing, Hui; Zhang, Hao; Liang, Hongjian; Cheng, Wen

    2016-09-01

    The use of SonoVue combined with ultrasound exposure increases the transfection efficiency of short interfering RNA (siRNA). The objective of this study was to prepare targeted nanobubbles (TNB) conjugated with NET-1 siRNA and an antibody GPC3 to direct nanobubbles to hepatocellular carcinoma cells. SMMC-7721 human hepatocellular carcinoma cells were treated with six different groups. The transfection efficiency and cellular apoptosis were measured by flow cytometry. The protein and messenger RNA (mRNA) expression were measured by Western blot and quantitative real-time PCR, respectively. The migration and invasion potential of the cells were determined by Transwell analysis. The results show that US-guided siRNA-TNB transfection effectively enhanced gene silencing. In summary, siRNA-TNB may be an effective delivery vector to mediate highly effective RNA interference in tumor treatment.

  9. Complete penile corporeal septation: evaluation with contrast enhanced US.

    PubMed

    Bertolotto, Michele; Bucci, Stefano; Quaia, Emilio; Coss, Matteo; Liguori, Giovanni

    2008-01-01

    Complete penile corporeal septation is a rare malformation in which the corpora cavernosa are completely isolated. We describe a new method to reach the diagnosis of this malformation using contrast enhanced US. Two patients with complete penile corporeal septation underwent color Doppler and contrast enhanced US after bilateral cavernosal injection of 10 microg prostaglandin E1. Contrast enhanced US was performed using a contrast specific software (Contrast-Tuned imaging, EsaOte, Genoa, Italy) and a linear transducer designed to evaluate superficial structures. Microbubbles of SonoVue (Bracco, Milan, Italy) were injected in one corpus cavernosum. After cavernosal injection of microbubbles no adverse events were observed. Contrast enhanced US showed unilateral enhancement of the corpus cavernosum in which microbubbles were injected. Cavernosography confirmed unilateral corporeal opacification. Contrast enhanced US can be used effectively to diagnose complete penile corporeal septation.

  10. Study Trapped Charge Distribution in P-Channel Silicon-Oxide-Nitride-Oxide-Silicon Memory Device Using Dynamic Programming Scheme

    NASA Astrophysics Data System (ADS)

    Li, Fu-Hai; Chiu, Yung-Yueh; Lee, Yen-Hui; Chang, Ru-Wei; Yang, Bo-Jun; Sun, Wein-Town; Lee, Eric; Kuo, Chao-Wei; Shirota, Riichiro

    2013-04-01

    In this study, we precisely investigate the charge distribution in SiN layer by dynamic programming of channel hot hole induced hot electron injection (CHHIHE) in p-channel silicon-oxide-nitride-oxide-silicon (SONOS) memory device. In the dynamic programming scheme, gate voltage is increased as a staircase with fixed step amplitude, which can prohibits the injection of holes in SiN layer. Three-dimensional device simulation is calibrated and is compared with the measured programming characteristics. It is found, for the first time, that the hot electron injection point quickly traverses from drain to source side synchronizing to the expansion of charged area in SiN layer. As a result, the injected charges quickly spread over on the almost whole channel area uniformly during a short programming period, which will afford large tolerance against lateral trapped charge diffusion by baking.

  11. Dam and Dcm methylations prevent gene transfer into Clostridium pasteurianum NRRL B-598: development of methods for electrotransformation, conjugation, and sonoporation.

    PubMed

    Kolek, Jan; Sedlar, Karel; Provaznik, Ivo; Patakova, Petra

    2016-01-01

    Butanol is currently one of the most discussed biofuels. Its use provides many benefits in comparison to bio-ethanol, but the price of its fermentative production is still high. Genetic improvements could help solve many problems associated with butanol production during ABE fermentation, such as its toxicity, low concentration achievable in the cultivation medium, the need for a relatively expensive substrate, and many more. Clostridium pasteurianum NRRL B-598 is non-type strain producing butanol, acetone, and a negligible amount of ethanol. Its main benefits are high oxygen tolerance, utilization of a wide range of carbon and nitrogen sources, and the availability of its whole genome sequence. However, there is no established method for the transfer of foreign DNA into this strain; this is the next step necessary for progress in its use for butanol production. We have described functional protocols for conjugation and transformation of the bio-butanol producer C. pasteurianum NRRL B-598 by foreign plasmid DNA. We show that the use of unmethylated plasmid DNA is necessary for efficient transformation or successful conjugation. Genes encoding DNA methylation and those for restriction-modification systems and antibiotic resistance were searched for in the whole genome sequence and their homologies with other clostridial bacteria were determined. Furthermore, activity of described novel type I restriction system was proved experimentally. The described electrotransformation protocol achieved an efficiency 1.2 × 10(2) cfu/μg DNA after step-by-step optimization and an efficiency of 1.6 × 10(2) cfu/μg DNA was achieved by the sonoporation technique using a standard laboratory ultrasound bath. The highest transformation efficiency was achieved using a combination of these approaches; sono/electroporation led to an increase in transformation efficiency, to 5.3 × 10(2) cfu/μg DNA. Both Dam and Dcm methylations are detrimental for transformation of C

  12. Working hours associated with unintentional sleep at work among airline pilots.

    PubMed

    Marqueze, Elaine Cristina; Nicola, Ana Carolina B; Diniz, Dag Hammarskjoeld M D; Fischer, Frida Marina

    2017-06-26

    Tto identify factors associated with unintentional sleep at work of airline pilots. This is a cross-sectional epidemiological study conducted with 1,235 Brazilian airline pilots, who work national or international flights. Data collection has been performed online. We carried out a bivariate and multiple logistic regression analysis, having as dependent variable unintentional sleep at work. The independent variables were related to biodemographic data, characteristics of the work, lifestyle, and aspects of sleep. The prevalence of unintentional sleep while flying the airplane was 57.8%. The factors associated with unintentional sleep at work were: flying for more than 65 hours a month, frequent technical delays, greater need for recovery after work, work ability below optimal, insufficient sleep, and excessive sleepiness. The occurrence of unintentional sleep at work of airline pilots is associated with factors related to the organization of the work and health. Identificar fatores associados aos cochilos não intencionais durante as jornadas de trabalho de pilotos da aviação regular. Estudo epidemiológico transversal conduzido com 1.235 pilotos brasileiros de avião do transporte aéreo regular, que realizavam voos nacionais ou internacionais, sendo a coleta de dados realizada on-line. Foi realizada análise de regressão logística bivariada e múltipla, tendo como variável dependente o cochilo não intencional durante o horário de trabalho. As variáveis independentes foram relacionadas a dados biodemográficos, características do trabalho, estilo de vida e aspectos do sono. A prevalência do cochilo não intencional enquanto pilotava o avião foi de 57,8%. Os fatores associados ao cochilo não intencional foram: voar por mais de 65 horas por mês, atrasos técnicos frequentes, maior necessidade de recuperação após o trabalho, capacidade para o trabalho inferior à ótima, sono insuficiente e sonolência excessiva. A ocorrência do cochilo n

  13. Recent advancements in the sonophotocatalysis (SPC) and doped-sonophotocatalysis (DSPC) for the treatment of recalcitrant hazardous organic water pollutants.

    PubMed

    Panda, Debabrata; Manickam, Sivakumar

    2017-05-01

    Sonophotocatalysis (SPC) is considered to be one of the important wastewater treatment techniques and hence attracted the attention of researchers to eliminate recalcitrant hazardous organic pollutants from aqueous phase. In general, SPC refers to the integrated use of ultrasonic sound waves, ultraviolet radiation and the addition of a semiconductor material which functions as a photocatalyst. Current research has brought numerous improvements in the SPC based treatment by opting visible light irradiation, nanocomposite catalysts and numerous catalyst supports for better stability and performance. This review accomplishes a critical analysis with respect to the recent advancements. The efficiency of SPC based treatments has been analyzed by considering the individual methods i.e. sonolysis, photocatalysis, sonophotolysis, sono-ozone, photo-Fenton and sono-Fenton. Besides, the essential parameters such as solution temperature, concentrations of initial pollutant and catalyst, initial pH, dosages of Fenton's reagent and hydrogen peroxide (H 2 O 2 ), ultrasonic power density, gas sparging, addition of radical scavenger, addition of carbon tetrachloride and methanol have been discussed with suggestions for the selection of optimum parameters. A higher synergistic pollutant removal rate has been reported during SPC treatment as compared to individual methods and the implementation of numerous doping materials and supports for the photocatalyst enhances the degradation rate of pollutants using DSPC under both visible and UV irradiation. Overall, SPC and DSPC based wastewater treatments are emerging as potential techniques as they provide effective solution in removing the recalcitrant organic pollutants and progressive research is expected to bring out superior treatment efficiency using these advanced technologies. The review has accomplished a thorough and a critical analysis of sonophotocatalysis (SPC) based on the recently published journals. Recent advancements in

  14. The Rotator Interval – A Link Between Anatomy and Ultrasound

    PubMed Central

    Tamborrini, Giorgio; Möller, Ingrid; Bong, David; Miguel, Maribel; Marx, Christian; Müller, Andreas Marc; Müller-Gerbl, Magdalena

    2017-01-01

    Shoulder pathologies of the rotator cuff of the shoulder are common in clinical practice. The focus of this pictorial essay is to discuss the anatomical details of the rotator interval of the shoulder, correlate the anatomy with normal ultrasound images and present selected pathologies. We focus on the imaging of the rotator interval that is actually the anterosuperior aspect of the glenohumeral joint capsule that is reinforced externally by the coracohumeral ligament, internally by the superior glenohumeral ligament and capsular fibers which blend together and insert medially and laterally to the bicipital groove. In this article we demonstrate the capability of high-resolution musculoskeletal ultrasound to visualize the detailed anatomy of the rotator interval. MSUS has a higher spatial resolution than other imaging techniques and the ability to examine these structures dynamically and to utilize the probe for precise anatomic localization of the patient’s pain by sono-palpation. PMID:28845477

  15. The Rotator Interval - A Link Between Anatomy and Ultrasound.

    PubMed

    Tamborrini, Giorgio; Möller, Ingrid; Bong, David; Miguel, Maribel; Marx, Christian; Müller, Andreas Marc; Müller-Gerbl, Magdalena

    2017-06-01

    Shoulder pathologies of the rotator cuff of the shoulder are common in clinical practice. The focus of this pictorial essay is to discuss the anatomical details of the rotator interval of the shoulder, correlate the anatomy with normal ultrasound images and present selected pathologies. We focus on the imaging of the rotator interval that is actually the anterosuperior aspect of the glenohumeral joint capsule that is reinforced externally by the coracohumeral ligament, internally by the superior glenohumeral ligament and capsular fibers which blend together and insert medially and laterally to the bicipital groove. In this article we demonstrate the capability of high-resolution musculoskeletal ultrasound to visualize the detailed anatomy of the rotator interval. MSUS has a higher spatial resolution than other imaging techniques and the ability to examine these structures dynamically and to utilize the probe for precise anatomic localization of the patient's pain by sono-palpation.

  16. [Trattamento farmacologico del disturbo da uso di alcol. Evidenze scientifiche].

    PubMed

    Attilia, Fabio; Perciballi, Roberta; Rotondo, Claudia; Capriglione, Ida; Iannuzzi, Silvia; Attilia, Maria Luisa; Vitali, Mario; Alessandrini, Giovanni; Scamporrino, Maria Concetta Marcella; Fiore, Marco; Ceccanti, Mauro

    2018-01-01

    RIASSUNTO. La terapia farmacologica nei pazienti con disturbo da uso di alcol riveste un ruolo centrale nel progetto terapeutico, altamente contestualizzato in un approccio multidisciplinare. Sebbene i trattamenti non farmacologici per la dipendenza da alcol risultino ben strutturati e in continua evoluzione, dal punto di vista medico le possibilità di intervento sono realmente ristrette, con poche molecole a disposizione approvate per il disturbo da uso di alcol: nello specifico, l'acamprostato, il naltrexone e, più recentemente, il nalmefene tra gli anticraving; il disulfiram tra gli avversivanti. Nuovi approcci sperimentali stanno cercando di ampliare tale gamma attraverso l'utilizzo di farmaci off-label. Evidenze scientifiche devono supportare l'indicazione terapeutica, quest'ultima deve dimostrarsi "cucita" sulle esigenze del paziente e sulle comorbilità presenti tenendo conto del profilo bio-psico-sociale individuale. Fondamentale risulta il follow-up per valutare la ritenzione in trattamento e il monitoraggio degli outcome alcologici.

  17. Photo-, sono- and sonophotocatalytic degradation of methylene blue using Fe3O4/ZrO2 composites catalysts

    NASA Astrophysics Data System (ADS)

    Kristianto, Y.; Taufik, A.; Saleh, R.

    2017-07-01

    In the present work, magnetite material Fe3O4/ZrO2 with various molar ratios was prepared by the two-step method (sol-gel followed by the ultrasonic-assisted method). The as-prepared samples were fairly characterized by various characterization methods, such as X-ray Diffraction (XRD), Vibrating Sample Magnetometer (VSM), Fourier Transform Infrared (FT-IR) and Thermal Gravimetric Analysis (TGA). The catalytic performance of the as-prepared samples was evaluated based on the degradation of methylene blue under UV light, ultrasound and combination of UV and ultrasound irradiation. The results revealed that the sample with Fe3O4:ZrO2 molar ratio of 0.5:1 showed the best catalytic performance under UV, ultrasound and UV + ultrasound irradiation. The degradation of methylene blue follows the order: sonophotocatalytic > sonocatalytic > photocatalytic. In addition, the effect of various scavengers has also been studied. Furthermore, all prepared samples could be used as a convenient recyclable catalyst.

  18. Photochemistry of matrix isolated (trifluoromethyl)sulfonyl azide, CF₃SO₂N₃.

    PubMed

    Zeng, Xiaoqing; Beckers, Helmut; Willner, Helge; Neuhaus, Patrik; Grote, Dirk; Sander, Wolfram

    2015-03-19

    The photochemistry of matrix isolated (trifluoromethylsulfonyl) azide, CF3SO2N3, has been studied at low temperatures. Upon ArF laser irradiation (λ = 193 nm), the azide eliminates N2 and furnishes triplet [(trifluoromethyl)sulfonyl]nitrene, CF3SO2N, which has been characterized by IR and EPR spectroscopy. Upon subsequent UV light irradiation (λ = 260-400 nm) the nitrene converts to CF3N═SO2 and CF3S(O)NO through a Curtius-type rearrangement. Further two new species CF2N═SO2F and FSNO were identified together with CF2NF, SO2, F2CO, CF3NO, and SO as side products. In addition, triplet nitrene CF3N was detected by its EPR and IR spectra. The complex stepwise photodecomposition of matrix isolated CF3SO2N3 is discussed in terms of the observed photolysis products and quantum chemical calculations.

  19. Videodensitometric Methods for Cardiac Output Measurements

    NASA Astrophysics Data System (ADS)

    Mischi, Massimo; Kalker, Ton; Korsten, Erik

    2003-12-01

    Cardiac output is often measured by indicator dilution techniques, usually based on dye or cold saline injections. Developments of more stable ultrasound contrast agents (UCA) are leading to new noninvasive indicator dilution methods. However, several problems concerning the interpretation of dilution curves as detected by ultrasound transducers have arisen. This paper presents a method for blood flow measurements based on UCA dilution. Dilution curves are determined by real-time densitometric analysis of the video output of an ultrasound scanner and are automatically fitted by the Local Density Random Walk model. A new fitting algorithm based on multiple linear regression is developed. Calibration, that is, the relation between videodensity and UCA concentration, is modelled by in vitro experimentation. The flow measurement system is validated by in vitro perfusion of SonoVue contrast agent. The results show an accurate dilution curve fit and flow estimation with determination coefficient larger than 0.95 and 0.99, respectively.

  20. [The role of endoscopy in gastroenteropancreatic neuroendocrine tumors].

    PubMed

    Magno, L; Sivero, L; Napolitano, V; Ruggiero, S; Fontanarosa, G; Massa, S

    2010-01-01

    Versione italiana Riassunto: Il ruolo dell'endoscopia nei tumori neuroendocrini gastroenteropancreatici. L. Magno, L. Sivero, V. Napolitano, S. Ruggiero, G. Fontanarosa, S. Massa I tumori neuroendocrini (NET) gastro-entero-pancreatici (GEP) sono neoplasie rare che originano dalle cellule neuroendocrine del tubo digerente e del pancreas. L'endoscopia digestiva e l'ecoendoscopia rivestono un ruolo importante nella diagnosi, stadiazione e sorveglianza dei pazienti con NET. Inoltre, in casi selezionati, le tecniche endoscopiche operative consentono il trattamento di queste neoplasie in fase precoce. English version Summary: The role of endoscopy in gastroenteropancreatic neuroendocrine tumors. L. Magno, L. Sivero, V. Napolitano, S. Ruggiero, G. Fontanarosa, S. Massa Gastroenteropancreatic (GEP) neuroendocrine tumors (NET) are rare neoplasia arisen from neuroendocrine cells present in the gut mucosa and pancreas. Digestive endoscopy and endoscopic ultrasonography play a relevant role in NET diagnosis, stadiation and surveillance. Moreover, in selected patients, surgical endoscopy allows the tratment of these cancers at an early stage.

  1. Design and Production of an Articulating Needle Guide for Ultrasound-Guided Needle Block Manufactured With a Three-Dimensional Printer: Technical Communication.

    PubMed

    Bigeleisen, Paul E

    2017-05-15

    Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.

  2. Integrative literature review: sleep patterns in infants attending nurseries.

    PubMed

    Cerqueira, Ana Carolina Dantas Rocha; Cardoso, Maria Vera Lúcia Moreira Leitão; Viana, Tamires Rebeca Forte; Lopes, Márcia Maria Coelho Oliveira

    2018-01-01

    To identify evidence available in the literature about sleep patterns of infants attending nurseries. An integrative review of studies published in Portuguese, English or Spanish available in full text on LILACS, CINAHL, and PubMed databases. The following descriptors sono, lactente and creches or berçários (in Portuguese) and sleep, infant and childcare or nurseries were used for LILACS, CINAHL and Pubmed, respectively. Nine studies were selected and analyzed. The main component explored in the studies about sleep pattern is the sleep position of the infants, due to its association with sudden infant death syndrome. The results pointed to the need to promote and develop written guidelines regarding behavioral practices to reduce the risk of this phenomenon. Evidence has identified sleep issues, mainly regarding the sleep position of the infant and the environment where the infant sleeps, showing that it is critical to set routines and interventions to improve the quality of sleep care of infants attending nurseries.

  3. Kinetic modeling and determination role of sono/photo nanocatalyst-generated radical species on degradation of hydroquinone in aqueous solution.

    PubMed

    Rahimi, Sajad; Ayati, Bita; Rezaee, Abbas

    2016-06-01

    Experimental findings of sonophotocatalytic process were used in degradation of hydroquinone to assess kinetic modeling and determine the effect of various active radical species. First, the effects of three photocatalytic, sonocatalytic, and sonophotocatalytic processes were studied for hydroquinone removal to determine kinetic constants and calculate the activation energy of reactions, and then the selected process was evaluated to determine active radical species. The reactor was composed of two parts, one included ultrasonic probe (sonocatalytic part) with powers 22, 80, and 176 W and the second part was the location of UV lamp (photocatalytic part) with tubular flow and power 15 W. After three systems were examined and the efficient system was selected, the role of different active species such as hydroxyl radical (OH(·)), superoxide radical (O2 (·-)), hole (h(+)), electrons (e (-)), and single oxygen molecule ((1)O2) and contribution of each of them were determined in hydroquinone degradation. According to tests, the results of this study showed that sonophotocatalytic integrated method as selected system among three systems studied followed the first-order equation for hydroquinone degradation and active hydroxyl species with 45 % and electron and hole with 15 and 10 %, respectively, had the highest and lowest contributions to conversion of hydroquinone. The findings showed that dissolved oxygen increases the capability of active radical formation so that 28.2 % of hydroquinone removal was increased under aeration compared to without aeration. Also, removal efficiency decreased 62 % with N2 injection due to the withdrawal of oxygen from the sample. By adding 25 Mm of sodium azide (NaN3) to stock solution, 46.5 % reduction was developed because single oxygen ((1)O2) played the role of an active species. The advantages of integrated sonocatalytic and photocatalytic method are the generation of active radical species with more variety and ultimately the formation of higher amounts of powerful hydroxyl radical that increases degradation rates of refractory compounds and low-risk internal and final products. It has an appropriate performance in the degradation of refractory compounds by optimizing effective operational factors.

  4. Calorimetria nucleare in collisioni tra ioni pesanti ad energie intermedie

    NASA Astrophysics Data System (ADS)

    Spezzi, L.

    2002-07-01

    Nel presente lavoro di tesi ci si e' occupati di uno studio sistematico di misure di temperatura ed energia di eccitazione in sistemi nucleari formati in reazioni tra ioni pesanti ad energie intermedie. La temperatura a stata misurata tramite due diversi metodi: rapporto tra le rese di isotopi che differiscono di uno stesso numero di nucleoni ( d/t-3He/4He , 3He/4He -6Li/7Li) - temperatura isotopica -, e rapporto tra le popolazioni degli stati eccitati in frammenti instabili (5Li e 6Li) che decadono in particelle leggere in coincidenza - temperatura di emissione. Le misure in esame sono state effettuate presso i Laboratori Nazionali del Sud per i sistemi 93Nb+93Nb, 93Nb+116,124Sn, 116,120Sn+116,124Sn e 116Sn+93Nb ad energie comprese tra 17 e 40 A MeV. L'apparato di rivelazione era costituito da un odoscopio ad alta granularite (96 telescopi Si (50micron)-Si(300micron)-CsI(Tl) ) e basse soglie di rivelazione, utilizzato sia per identificare risonanze in frammenti eccitati che per misure di rese di isotopi di frammenti con 2<=Z<=6, e dal multirivelatore FIASCO che, grazie alla misura contemporanea di posizione e tempo di volo dei frammenti provenienti dal proiettile (PLF - Projectile Like Fragments) e dal bersaglio (TLF - Target Like Fragment), e' stato utilizzato per misurare direttamente l'energia di eccitazione del sistema in studio. Analisi precedenti, condotte nell'ambito di varie collaborazioni, hanno messo in evidenza la possible esistenza di una transizione di fase liquido-gas del primo ordine nella materia nucleare. In tale contesto, ci siamo occupati di una verifica della curva calorica nucleare, ovvero della correlazione esistente fra temperatura ed energia di eccitazione del sistema, indagando, nel contempo, sulla sua dipendenza dalla massa del sistema che si frammenta. Si e' effettuato, inoltre, un confronto fra i due diversi metodi di misura della temperatura (temperatura isotopica e di emissione): l'andamento plateau-like della curva calorica e' stato

  5. Synthesis, characterization and electrocatalytic properties of delafossite CuGaO2

    NASA Astrophysics Data System (ADS)

    Ahmed, Jahangeer; Mao, Yuanbing

    2016-10-01

    Delafossite CuGaO2 has been employed as photocatalysts for solar cells, but their electrocatalytic properties have not been extensively studied, especially no comparison among samples made by different synthesis routes. Herein, we first reported the successful synthesis of delafossite CuGaO2 particles with three different morphologies, i.e. nanocrystalline hexagons, sub-micron sized plates and micron-sized particles by a modified hydrothermal method at 190 °C for 60 h [1-3], a sono-chemical method followed by firing at 850 °C for 48 h, and a solid state route at 1150 °C, respectively. Morphology, composition and phase purity of the synthesized samples was confirmed by powder X-ray diffraction and Raman spectroscopic studies, and then their electrocatalytic performance as active and cost effective electrode materials to the oxygen and hydrogen evolution reactions in 0.5 M KOH electrolyte versus Ag/AgCl was investigated and compared under the same conditions for the first time. The nanocrystalline CuGaO2 hexagons show enhanced electrocatalytic activity than the counterpart sub-micron sized plates and micron-sized particles.

  6. Ultrasonographic assessment of the equine palmar tendons

    PubMed Central

    Padaliya, N. R.; Ranpariya, J. J.; Kumar, Dharmendra; Javia, C. B.; Barvalia, D. R.

    2015-01-01

    Aim: The present study was conducted to evaluate the equine palmar tendon by ultrasonography (USG) in standing the position. Materials and Methods: USG of palmar tendons was performed in 40 adult horses using linear transducer having frequency of 10-18 MHz (e-soate, My Lab FIVE) and L52 linear array transducer (Titan, SonoSite) with frequencies ranging from 8 to 10 MHz. Palmar tendon was divided into 7 levels from distal to accessory carpal bone up to ergot in transverse scanning and 3 levels in longitudinal scanning. Results: The USG evaluation was very useful for diagnosis of affections of the conditions such as chronic bowed tendon, suspensory ligament desmitis, carpal sheath tenosynovitis and digital sheath effusions. The mean cross-sectional area (cm2) of affected tendons was significantly increased in affected than normal tendons. The echogenicity was also found reduced in affected tendons and ligaments along with disorganization of fiber alignment depending on the severity of lesion and injury. Conclusion: USG proved ideal diagnostic tool for diagnosis and post-treatment healing assessment of tendon injuries in horses. PMID:27047074

  7. Biodegradable double-targeted PTX-mPEG-PLGA nanoparticles for ultrasound contrast enhanced imaging and antitumor therapy in vitro.

    PubMed

    Ma, Jing; Shen, Ming; Xu, Chang Song; Sun, Ying; Duan, You Rong; Du, Lian Fang

    2016-11-29

    A porous-structure nano-scale ultrasound contrast agent (UCA) was made of monomethoxypoly (ethylene glycol)-poly (lactic-co-glycolic acid) (mPEG-PLGA), and modified by double-targeted antibody: anti-carcinoembryonic antigen (CEA) and anti-carbohydrate antigen 19-9 (CA19-9), as a double-targeted nanoparticles (NPs). Anti-tumor drug paclitaxel (PTX) was encapsulated in the double-targeted nanoparticles (NPs). The morphor and release curve were characterized. We verified a certain anticancer effect of PTX-NPs through cytotoxicity experiments. The cell uptake result showed much more NPs may be facilitated to ingress the cells or tissues with ultrasound (US) or ultrasound targeted microbubble destruction (UTMD) transient sonoporation in vitro. Ultrasound contrast-enhanced images in vitro and in vivo were investigated. Compared with SonoVue, the NPs prolonged imaging time in rabbit kidneys and tumor of nude mice, which make it possible to further enhance anti-tumor effects by extending retention time in the tumor region. The novel double-targeted NPs with the function of ultrasound contrast enhanced imaging and anti-tumor therapy can be a promising way in clinic.

  8. Preparation of amorphous cefuroxime axetil nanoparticles by sonoprecipitation for enhancement of bioavailability.

    PubMed

    Dhumal, Ravindra S; Biradar, Shailesh V; Yamamura, Shigeo; Paradkar, Anant R; York, Peter

    2008-09-01

    The aim of the present work was to prepare amorphous discreet nanoparticles by sonoprecipitation method for enhancing oral bioavailability of cefuroxime axetil (CA), a poorly water-soluble drug. CA nanoparticles (SONO-CA) were prepared by sonoprecipitation and compared with particles obtained by precipitation without sonication (PPT-CA) and amorphous CA obtained by spray drying. Spray drying present broad particle size distribution (PSD) with mean particle size of 10 microm and low percent yield, whereas, precipitation without sonication resulted in large amorphous aggregates with broad PSD. During sonoprecipitation, particle size and yield improve with an increase in the amplitude of sonication and lowering the operation temperature due to instantaneous supersaturation and nucleation. The overall symmetry and purity of CA molecule was maintained as confirmed by FTIR and HPLC, respectively. All the three methods resulted in the formation of amorphous CA with only sonoprecipitation resulting in uniform sized nanoparticles. Sonoprecipitated CA nanoparticles showed enhanced dissolution rate and oral bioavailability in Wistar rat due to an increased solubility attributed to combination of effects like amorphization and nanonization with increased surface area and reduced diffusion pathway.

  9. Physiotherapy interventions for patients with chronic pelvic pain: A systematic review of the literature.

    PubMed

    Fuentes-Márquez, Pedro; Cabrera-Martos, Irene; Valenza, Marie Carmen

    2018-05-14

    To summarize the available scientific evidence on physiotherapy interventions in the management of chronic pelvic pain (CPP). A systematic review of randomized controlled trials was performed. An electronic search of MEDLINE, CINAHL, and Web of Science databases was performed to identify relevant randomized trials from 2010-2016. Manuscripts were included if at least one of the comparison groups received a physiotherapy intervention. Studies were assessed in duplicate for data extraction and risk of bias using the Physiotherapy Evidence Database scale PEDro. Eight of the studies screened met the inclusion criteria. Four manuscripts studied the effects of electrotherapy including intravaginal electrical stimulation, short wave diathermy, respiratory-gated auricular vagal afferent nerve stimulation, percutaneous tibial nerve stimulation, and sono-electro-magnetic therapy with positive results. Three studies focused on manual assessing the efficacy of myofascial versus massage therapy in two of them and ischemic compression for trigger points. Although physiotherapy interventions show some beneficial effects, evidence cannot support the results. Heterogeneity in terms of population phenotype, methodological quality, interpretation of results, and operational definition result in little overall evidence to guide treatment.

  10. Effect of sonically induced deflocculation on the efficiency of ozone mediated partial sludge disintegration for improved production of biogas.

    PubMed

    Sowmya Packyam, G; Kavitha, S; Adish Kumar, S; Kaliappan, S; Yeom, Ick Tae; Rajesh Banu, J

    2015-09-01

    In this study, ultrasonication was used for sludge deflocculation, followed by cell disintegration using ozone. The effect of this phase separated sono-ozone pretreatment is evaluated based on extra polymeric substances release, deoxyribonucleic acid (DNA) in the medium, solubilization of intra cellular components and suspended solids (SS) reduction. Ultrasonically induced deflocculation was optimized at an energy dosage of 76.4(log 1.88)kJ/kg TS. During cell disintegration (ozone dosage 0.0011 mgO3/mgSS), chemical oxygen demand solubilization (COD) and SS reduction of sonic mediated ozone pretreated sludge were 25.4% and 17.8% comparatively higher than ozone pretreated sludge, respectively. Further, biogas production potential of control (raw), flocculated (ozone pretreated), and deflocculated (sonic mediated ozone pretreated) sludges were observed to be 0.202, 0.535 and 0.637 L/(gVS), respectively. Thus, the phase separated pretreatment at lower ultrasonic specific energy and low dose ozone proved to enhance the anaerobic biodegradability efficiently. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Cardiac elastography: detecting pathological changes in myocardium tissues

    NASA Astrophysics Data System (ADS)

    Konofagou, Elisa E.; Harrigan, Timothy; Solomon, Scott

    2003-05-01

    Estimation of the mechanical properties of the cardiac muscle has been shown to play a crucial role in the detection of cardiovascular disease. Elastography was recently shown feasible on RF cardiac data in vivo. In this paper, the role of elastography in the detection of ischemia/infarct is explored with simulations and in vivo experiments. In finite-element simulations of a portion of the cardiac muscle containing an infarcted region, the cardiac cycle was simulated with successive compressive and tensile strains ranging between -30% and 20%. The incremental elastic modulus was also mapped uisng adaptive methods. We then demonstrated this technique utilizing envelope-detected sonographic data (Hewlett-Packard Sonos 5500) in a patient with a known myocardial infarction. In cine-loop and M-Mode elastograms from both normal and infarcted regions in simulations and experiments, the infarcted region was identifed by the up to one order of magnitude lower incremental axial displacements and strains, and higher modulus. Information on motion, deformation and mechanical property should constitute a unique tool for noninvasive cardiac diagnosis.

  12. Temperature-dependent differences in the nonlinear acoustic behavior of ultrasound contrast agents revealed by high-speed imaging and bulk acoustics.

    PubMed

    Mulvana, Helen; Stride, Eleanor; Tang, Mengxing; Hajnal, Jo V; Eckersley, Robert

    2011-09-01

    Previous work by the authors has established that increasing the temperature of the suspending liquid from 20°C to body temperature has a significant impact on the bulk acoustic properties and stability of an ultrasound contrast agent suspension (SonoVue, Bracco Suisse SA, Manno, Lugano, Switzerland). In this paper the influence of temperature on the nonlinear behavior of microbubbles is investigated, because this is one of the most important parameters in the context of diagnostic imaging. High-speed imaging showed that raising the temperature significantly influences the dynamic behavior of individual microbubbles. At body temperature, microbubbles exhibit greater radial excursion and oscillate less spherically, with a greater incidence of jetting and gas expulsion, and therefore collapse, than they do at room temperature. Bulk acoustics revealed an associated increase in the harmonic content of the scattered signals. These findings emphasize the importance of conducting laboratory studies at body temperature if the results are to be interpreted for in vivo applications. Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. Theoretical model of ice nucleation induced by acoustic cavitation. Part 1: Pressure and temperature profiles around a single bubble.

    PubMed

    Cogné, C; Labouret, S; Peczalski, R; Louisnard, O; Baillon, F; Espitalier, F

    2016-03-01

    This paper deals with the inertial cavitation of a single gas bubble in a liquid submitted to an ultrasonic wave. The aim was to calculate accurately the pressure and temperature at the bubble wall and in the liquid adjacent to the wall just before and just after the collapse. Two different approaches were proposed for modeling the heat transfer between the ambient liquid and the gas: the simplified approach (A) with liquid acting as perfect heat sink, the rigorous approach (B) with liquid acting as a normal heat conducting medium. The time profiles of the bubble radius, gas temperature, interface temperature and pressure corresponding to the above models were compared and important differences were observed excepted for the bubble size. The exact pressure and temperature distributions in the liquid corresponding to the second model (B) were also presented. These profiles are necessary for the prediction of any physical phenomena occurring around the cavitation bubble, with possible applications to sono-crystallization. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Dynamic 3D echocardiography in virtual reality

    PubMed Central

    van den Bosch, Annemien E; Koning, Anton HJ; Meijboom, Folkert J; McGhie, Jackie S; Simoons, Maarten L; van der Spek, Peter J; Bogers, Ad JJC

    2005-01-01

    Background This pilot study was performed to evaluate whether virtual reality is applicable for three-dimensional echocardiography and if three-dimensional echocardiographic 'holograms' have the potential to become a clinically useful tool. Methods Three-dimensional echocardiographic data sets from 2 normal subjects and from 4 patients with a mitral valve pathological condition were included in the study. The three-dimensional data sets were acquired with the Philips Sonos 7500 echo-system and transferred to the BARCO (Barco N.V., Kortrijk, Belgium) I-space. Ten independent observers assessed the 6 three-dimensional data sets with and without mitral valve pathology. After 10 minutes' instruction in the I-Space, all of the observers could use the virtual pointer that is necessary to create cut planes in the hologram. Results The 10 independent observers correctly assessed the normal and pathological mitral valve in the holograms (analysis time approximately 10 minutes). Conclusion this report shows that dynamic holographic imaging of three-dimensional echocardiographic data is feasible. However, the applicability and use-fullness of this technology in clinical practice is still limited. PMID:16375768

  15. Durable antimicrobial cotton textiles coated sonochemically with ZnO nanoparticles embedded in an in-situ enzymatically generated bioadhesive.

    PubMed

    Salat, Marc; Petkova, Petya; Hoyo, Javier; Perelshtein, Ilana; Gedanken, Aharon; Tzanov, Tzanko

    2018-06-01

    An important preventive measure for providing a bacteria-free environment for the patients is the introduction of highly efficient and durable antibacterial textiles in hospitals. This work describes a single step sono-enzymatic process for coating of cotton medical textiles with antibacterial ZnO nanoparticles (NPs) and gallic acid (GA) to produce biocompatible fabrics with durable antibacterial properties. Cellulose substrates, however, need pre-activation to achieve sufficient stability of the NPs on their surface. Herein, this drawback is overcome by the simultaneous sonochemical deposition of ZnO NPs and the synthesis of a bio-based adhesive generated by the enzymatic cross-linking of GA in which the NPs were embedded. GA possesses the multiple functions of an antibacterial agent, a building block of the cross-linked phenolic network, and as a compound providing the safe contact of the coated materials with human skin. The ZnO NPs-GA coated fabrics maintained above 60% antibacterial efficacy even after 60 washing cycles at 75 °C hospital laundry regime. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Elettrodinamica classica

    NASA Astrophysics Data System (ADS)

    Lechner, Kurt

    Nella scoperta della Relatività Ristretta l'Elettrodinamica, rappresentando una teoria relativistica per eccellenza, ha giocato un ruolo fondamentale. Il principio di relativit` a einsteiniana, che afferma che tutte le leggi della fisica devono avere la stessa forma in tutti i sistemi di riferimento inerziali, è emerso con forza da questa teoria ed è andato consolidandosi sempre di più, man mano che le nostre conoscenze del mondo microscopico sono diventate più complete: tutte le interazioni fondamentali rispettano infatti tale principio. Il modo più semplice ed elegante per implementarlo — difatti l'unico di un'utilità concreta — è rappresentato dal paradigma della covarianza a vista nell'ambito del calcolo tensoriale. Questo paradigma è stato applicato con successo a tutte le teorie di carattere fondamentale, come le teorie che descrivono le quattro interazioni fondamentali e le più speculative teorie di superstringa, e mantiene la sua piena efficacia anche in teoria quantistica. La nostra esposizione dell'Elettrodinamica classica si baserà dunque a ragione su questo paradigma.

  17. Homogeneous sonophotolysis of food processing industry wastewater: Study of synergistic effects, mineralization and toxicity removal.

    PubMed

    Durán, A; Monteagudo, J M; Sanmartín, I; Gómez, P

    2013-03-01

    The mineralization of industrial wastewater coming from food industry using an emerging homogeneous sonophotolytic oxidation process was evaluated as an alternative to or a rapid pretreatment step for conventional anaerobic digestion with the aim of considerably reducing the total treatment time. At the selected operation conditions ([H(2)O(2)]=11,750ppm, pH=8, amplitude=50%, pulse length (cycles)=1), 60% of TOC is removed after 60min and 98% after 180min when treating an industrial effluent with 2114ppm of total organic carbon (TOC). This process removed completely the toxicity generated during storing or due to intermediate compounds. An important synergistic effect between sonolysis and photolysis (H(2)O(2)/UV) was observed. Thus the sonophotolysis (ultrasound/H(2)O(2)/UV) technique significantly increases TOC removal when compared with each individual process. Finally, a preliminary economical analysis confirms that the sono-photolysis with H(2)O(2) and pretreated water is a profitable system when compared with the same process without using ultrasound waves and with no pretreatment. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. [Trattamento della dipendenza da alcol. Alcol e giovani: punto di vista sociale].

    PubMed

    Alessandrini, Giovanni; Ciccarelli, Rosaria; Battagliese, Gemma; Lombardo, Giuseppe; De Rosa, Francesca; Messina, Marisa Patrizia; Vitali, Mario; Pisciotta, Fabiola; Nanut, Miriana; Attilia, Maria Luisa; Ceccanti, Mauro

    2018-01-01

    RIASSUNTO. Gli adolescenti rappresentano la fascia di età più vulnerabile ai danni causati dall'abuso di alcol, in quanto iniziare a bere in giovane età è associato a un aumento del rischio di dipendenza da alcolici in età adulta. I giovani tendono a bere grandi quantità di alcolici al fine di ricercare forti emozioni e nel tentativo di raggiungere il divertimento a ogni costo, tramite le proprietà psicotrope degli alcolici. Le cause che li inducono ad assumere questi comportamenti sono da ricercare nella non conoscenza degli effetti dannosi dell'alcol, nel rito di convivialità sociale (evenienza per la quale si attribuisce all'alcol la funzione di facilitatore dell'aggregazione tra giovani), nella mancanza di interessi personali, nella scarsità dei controlli e nelle abitudini familiari. Le azioni da intraprendere per limitare o arrestare il consumo nocivo di alcol nei giovani si devono basare su interventi finalizzati a ritardare l'età del primo contatto con le bevande alcoliche, mediante la realizzazione di campagne educazionali rivolte ai giovani stessi, ai loro familiari e alla società intera.

  19. Threshold voltage variation depending on single grain boundary and stored charges in an adjacent cell for vertical silicon–oxide–nitride–oxide–silicon NAND flash memory

    NASA Astrophysics Data System (ADS)

    Oh, Hyeongwan; Kim, Jiwon; Baek, Rock-Hyun; Lee, Jeong-Soo

    2018-04-01

    The effects of single grain boundary (SGB) position and stored electron charges in an adjacent cell in silicon–oxide–nitride–oxide–silicon (SONOS) structures on the variations of threshold voltage (V th) were investigated using technology computer-aided design (TCAD) simulation. As the bit line voltage increases, the SGB position causing the maximum V th variation was shifted from the center to the source side in the channel, owing to the drain-induced grain barrier lowering effect. When the SGB is located in the spacer region, the potential interaction from both the SGB and the stored electron charges in the adjacent cell becomes significant and thus resulting in larger V th variation. In contrast, when the SGB is located at the center of the channel, the peak position of potential barrier is shifted to the center, so that the influence of the adjacent cell is diminished. As the gate length is scaled down to 20 nm, the influence of stored charges in adjacent cells becomes significant, resulting in larger V th variations.

  20. Non-invasive magnetic resonance imaging follow-up of sono-sensitive liposome tumor delivery and controlled release after high-intensity focused ultrasound.

    PubMed

    Fowler, Robert Andrew; Fossheim, Sigrid L; Mestas, Jean-Louis; Ngo, Jacqueline; Canet-Soulas, Emmanuelle; Lafon, Cyril

    2013-12-01

    This work examines the use of lanthanide-based contrast agents and magnetic resonance imaging in monitoring liposomal behavior in vivo. Dysprosium (Dy) and gadolinium (Gd) chelates, Dy-diethylenetriaminepentaacetic acid bismethylamide (Dy-DTPA-BMA) and Gd-DTPA-BMA, were encapsulated in pegylated distearoylphosphatidylethanolamine-based (saturated) liposomes, and then intravenously injected into Copenhagen rats with subcutaneous Dunning AT2 xenografts. Liposome-encapsulated Dy chelate shortens transverse relaxation times (T(2) and T(2)*) of tissue; thus, liposomal accumulation in the tumor can be monitored by observing the decrease in T(2)* relaxation time over time. The tumor was treated at the time of maximum liposomal accumulation (48 h) with confocal, cavitating high-intensity focused ultrasound to induce liposomal payload release. Using liposome-encapsulated Gd chelate at high enough concentrations and saturated liposomal phospholipids induces an exchange-limited longitudinal (T(1)) relaxation when the liposomes are intact; when the liposomes are released, exchange limitation is relieved, thus allowing in vivo observation of payload release as a decrease in tumor T(1). Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. Experimental study of three-dimensional fin-channel charge trapping flash memories with titanium nitride and polycrystalline silicon gates

    NASA Astrophysics Data System (ADS)

    Liu, Yongxun; Matsukawa, Takashi; Endo, Kazuhiko; O'uchi, Shinichi; Tsukada, Junichi; Yamauchi, Hiromi; Ishikawa, Yuki; Mizubayashi, Wataru; Morita, Yukinori; Migita, Shinji; Ota, Hiroyuki; Masahara, Meishoku

    2014-01-01

    Three-dimensional (3D) fin-channel charge trapping (CT) flash memories with different gate materials of physical-vapor-deposited (PVD) titanium nitride (TiN) and n+-polycrystalline silicon (poly-Si) have successfully been fabricated by using (100)-oriented silicon-on-insulator (SOI) wafers and orientation-dependent wet etching. Electrical characteristics of the fabricated flash memories including statistical threshold voltage (Vt) variability, endurance, and data retention have been comparatively investigated. It was experimentally found that a larger memory window and a deeper erase are obtained in PVD-TiN-gated metal-oxide-nitride-oxide-silicon (MONOS)-type flash memories than in poly-Si-gated poly-Si-oxide-nitride-oxide-silicon (SONOS)-type memories. The larger memory window and deeper erase of MONOS-type flash memories are contributed by the higher work function of the PVD-TiN metal gate than of the n+-poly-Si gate, which is effective for suppressing electron back tunneling during erase operation. It was also found that the initial Vt roll-off due to the short-channel effect (SCE) is directly related to the memory window roll-off when the gate length (Lg) is scaled down to 46 nm or less.

  2. Experimental investigation of the penetration of ultrasound nanobubbles in a gastric cancer xenograft.

    PubMed

    Fan, Xiaozhou; Wang, Luofu; Guo, Yanli; Tong, Haipeng; Li, Lang; Ding, Jun; Huang, Haiyun

    2013-08-16

    Nanobubbles as a type of ultrasound contrast agent have attracted much interest in recent years due to their many advantages, such as strong penetrating power and high stability. However, there is still insufficient morphological evidence concerning gas-filled nanobubbles in tumor tissue spaces and tumor angiogenesis. We used a gastric cancer xenograft as an example to study this question. Nanobubbles with a particle size of 435.2 ± 60.53 nm were prepared and compared with SonoVue® microbubbles in vitro and in vivo, and they exhibited a superior contrast imaging effect. After excluding the impact of the nanobubbles in blood vessels through saline flush, we used an ultrasound burst and frozen sectioning to investigate the distribution of nanobubbles in the gastric cancer xenografts and confirmed this by transmission electron microscopy. Preliminary results showed that the nanobubbles were able to pass through the gaps between the endothelial cells in the tumor vascular system to enter the tissue space. These findings could provide morphological evidence for extravascular ultrasound imaging of tumors and serve as a foundation for the application of nanobubbles in extravascular tumor-targeted ultrasonic diagnostics and therapy.

  3. How close are we? An audit of biometry of a tertiary care hospital in Karachi.

    PubMed

    Siddiqui, Abdul Hameed; Khan, Maria; Hussain, Marium

    2018-01-01

    To evaluate the accuracy of biometry in the post-op phase of cataract surgery. This study was conducted at Liaquat National Hospital, Karachi, from June 2015 to July 2016, and comprised the audit of patients who underwent cataract surgery during the period. Keratometry was done on Haag-Strait manual keratometer and A-scan was done by applanation contact method on SonoMed machine. Theoretic-T formula was used to calculate desired intraocular lens power for all kinds of axial lengths. A single surgeon operated upon the same Alcon Constellation phacoemulsification machine. Postoperative follow-up was done by monitoring auto refraction and visual acuity on days 1, 7, 30 and 90. SPSS 21 was used for data analysis.. Of 244 patients, 121(49.60%) were males and 123(50.40%) were females. There were 123(50.40%) right eyes and 121(49.60%) left eyes. Overall, 132(54.10%) achieved postoperative refraction within ±0.5 D of target and 193(79.10%) within ±1 D of target. Age, gender and laterality had no significant effect on outcomes (p>0.05 each). Postoperative refraction corresponded quite closely with global recommendations.

  4. Quiescent Volcano-Chest Wall Hemangioma.

    PubMed

    Saldanha, Elroy; Martis, John J S; Kumar, B Vinod; D'Cunha, Rithesh J; Vijin, V

    2017-08-01

    Chest wall hemangiomas are rare tumors that may originate within the soft tissue or from the ribs. Intramuscular hemangioma is infrequent, representing less than 1 % of all hemangiomas, and the localization in the chest wall is even less frequent. They are typically cutaneous in location, large, and poorly circumscribed and can be locally destructive. We present a case of a 34-year-old lady presented with firm lump 3 × 3 cm in left upper and inner quadrant of left breast well defined borders, non-pulsatile and restricted mobility. Sono-mammogram was suggestive of ill-defined lesion at 10 o'clock position. CT chest was conclusive of chest wall hemangioma. The patient underwent excision of the lump. HPE was suggestive of cavernous hemangioma. Cavernous hemangioma typically manifest at birth or before the age of 30 years. CT is more sensitive than plain radiography in detecting phleboliths, which are present in approximately 30 % of cavernous hemangiomas. Surgical excision would be treatment of choice. In this case, the site of the lesion was in the breast clinically mimicking that of a fibroadenoma which warrants hemangioma as a differential diagnosis.

  5. Highly Sensitive Nanostructured SnO2 Thin Films For Hydrogen Sensing

    NASA Astrophysics Data System (ADS)

    Patil, L. A.; Shinde, M. D.; Bari, A. R.; Deo, V. V.

    2010-10-01

    Nanostructured SnO2 thin films were prepared by ultrasonic spray pyrolysis technique. Aqueous solution (0.05 M) of SnCl4ṡ5H2O in double distilled water was chosen as the starting solution for the preparation of the films. The stock solution was delivered to nozzle with constant and uniform flow rate of 70 ml/h by Syringe pump SK5001. Sono-tek spray nozzle, driven by ultrasonic frequency of 120 kHz, converts the solution into fine spray. The aerosol produced by nozzle was sprayed on glass substrate heated at 150 °C. The sensing performance of the films was tested for various gases such as LPG, hydrogen, ethanol, carbon dioxide and ammonia. The sensor (30 min) showed high gas response (S = 3040 at 350 °C) on exposure of 1000 ppm of hydrogen and high selectivity against other gases. Its response time was short (2 s) and recovery was also fast (12 s). To understand reasons behind this uncommon gas sensing performance of the films, their structural, microstructural, and optical properties were studied using X-ray diffraction, electron microscopy (SEM and TEM) respectively. The results are interpreted

  6. Complete diagnostics and clinical approach for a female patient with unusual glioblastoma: A case study.

    PubMed

    Samal, Filip; Stanek, Libor; Filip, Michal; Haninec, Pavel; Vícha, Ales; Musil, Zdenek; Tesarova, Petra; Petruzelka, Lubos; Springer, Drahomira; Kralickova, Milena; Kohoutova, Milada; Zima, Tomas

    2016-07-01

    The present study reports a case of a 44-year-old female patient with a large frontal lobe tumor who underwent surgery using a modern navigation system SonoWand that combines the advantages of a non-frame navigation system with intraoperative real-time ultrasound imaging. The right frontal lobe tumor consisted of two morphologically different sections. A diffuse astrocytoma grade II and a glioblastoma grade IV were identified. These tumors were relatively substantially separated. A 17 p deletion, including TP53 , was detected in a diffuse astrocytoma but not in a glioblastoma. EGFR and MDM2 amplifications were detected only in a glioblastoma. Detection of these amplifications is typical for primary glioblastomas. These findings support our assumption of two independent tumors. The KRAS , BRAF and EGFR gene mutations were also detected in a glioblastoma. Such an accumulation of molecular mutations is rare in one tumor. Following oncological treatment the patient was cared for in the oncological center and survived for 15 months after the surgery without any signs of a disease. This is an unusual case, and to the best of our knowledge, is not frequently published in literature.

  7. Experimental investigation of the penetration of ultrasound nanobubbles in a gastric cancer xenograft

    NASA Astrophysics Data System (ADS)

    Fan, Xiaozhou; Wang, Luofu; Guo, Yanli; Tong, Haipeng; Li, Lang; Ding, Jun; Huang, Haiyun

    2013-08-01

    Nanobubbles as a type of ultrasound contrast agent have attracted much interest in recent years due to their many advantages, such as strong penetrating power and high stability. However, there is still insufficient morphological evidence concerning gas-filled nanobubbles in tumor tissue spaces and tumor angiogenesis. We used a gastric cancer xenograft as an example to study this question. Nanobubbles with a particle size of 435.2 ± 60.53 nm were prepared and compared with SonoVue® microbubbles in vitro and in vivo, and they exhibited a superior contrast imaging effect. After excluding the impact of the nanobubbles in blood vessels through saline flush, we used an ultrasound burst and frozen sectioning to investigate the distribution of nanobubbles in the gastric cancer xenografts and confirmed this by transmission electron microscopy. Preliminary results showed that the nanobubbles were able to pass through the gaps between the endothelial cells in the tumor vascular system to enter the tissue space. These findings could provide morphological evidence for extravascular ultrasound imaging of tumors and serve as a foundation for the application of nanobubbles in extravascular tumor-targeted ultrasonic diagnostics and therapy.

  8. Duration of ultrasound-mediated enhanced plasma membrane permeability.

    PubMed

    Lammertink, Bart; Deckers, Roel; Storm, Gert; Moonen, Chrit; Bos, Clemens

    2015-03-30

    Ultrasound (US) induced cavitation can be used to enhance the intracellular delivery of drugs by transiently increasing the cell membrane permeability. The duration of this increased permeability, termed temporal window, has not been fully elucidated. In this study, the temporal window was investigated systematically using an endothelial- and two breast cancer cell lines. Model drug uptake was measured as a function of time after sonication, in the presence of SonoVue™ microbubbles, in HUVEC, MDA-MB-468 and 4T1 cells. In addition, US pressure amplitude was varied in MDA-MB-468 cells to investigate its effect on the temporal window. Cell membrane permeability of HUVEC and MDA-MB-468 cells returned to control level within 1-2 h post-sonication, while 4T1 cells needed over 3h. US pressure affected the number of cells with increased membrane permeability, as well as the temporal window in MDA-MB-468 cells. This study shows that the duration of increased membrane permeability differed between the cell lines and US pressures used here. However, all were consistently in the order of 1-3 h after sonication. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Lo Gnomone Clementino Astronomia Meridiana in Basilica

    NASA Astrophysics Data System (ADS)

    Sigismondi, Costantino

    2014-05-01

    Costruito per chiara volontà del papa 70 anni dopo il caso Galileo, lo Gnomone Clementino è un grande telescopio solare che non fa uso di lenti a 92 anni dall’invenzione del cannocchiale. Queste due caratteristiche basterebbero da sole a giustificare l’interesse verso questo strumento. L’astronomia meridiana è alla base dell’astrometria e dell’astrofisica moderna. Lo Gnomone Clementino sta oggi all’astronomia, come il veliero “Amerigo Vespucci” sta alla Marina Italiana. E’ possibile svolgere ogni genere di osservazione e studio su questo strumento, e dal 2002 vi tengo lezioni teorico-pratiche del corso di Storia dell’Astronomia e La Terra nel Sistema Solare della Sapienza, Università di Roma, Facoltà di Lettere e Filosofia. Questo testo aggiunge alcuni tasselli alla ricerca storica sulla meridiana, appoggiandosi, com’è naturale, sulle spalle di giganti che mi hanno preceduto in questi studi. In particolare la misura dell’azimut della meridiana, ed il suo inquadramento tra gli strumenti simili ed alcuni studi di astrometria sui dati del 1701-1703 di Bianchini, che sono apparsi fin’ora soltanto su riviste specializzate ed in Inglese vengono qui proposti in Italiano e semplificati, per valorizzare sempre più questa straordinaria opera d’arte e di scienza.

  10. Transrectal contrast-enhanced ultrasonography, transrectal ultrasonography and retrograde cystography for the detection of vesicourethral anastomosis leakage after radical retropubic prostatectomy: a prospective comparative evaluation.

    PubMed

    Cantiello, Francesco; Cicione, Antonio; Autorino, Riccardo; De Nunzio, Cosimo; Tubaro, Andrea; Damiano, Rocco

    2013-01-01

    To evaluate the diagnostic accuracy of cystography (CG), transrectal ultrasonography (TRUS) and transrectal contrast-enhanced ultrasonography (CEUS) for the detection of vesicourethral extravasation (VE) after radical retropubic prostatectomy (RRP). In 80 consecutive patients who underwent RRP, the strength of the vesicourethral anastomosis (VUA) was assessed by CG, TRUS and transrectal CEUS. The investigation started with a conventional CG evaluated by an experienced uroradiologist. Following this, patients underwent TRUS which was performed by an experienced urologist who was blinded to the CG findings. The examination started with a conventional B-scan and, subsequently, a CEUS was performed by emptying and refilling the bladder with 90 ml of NaCl 0.9% + 10 ml suspension of 1:10 SonoVue and NaCl 0.9%. 26 patients (32.5%) presented urinary VE and 54 (67.5%) a watertight VUA. In 16 patients (61%) we observed a small leakage, 9 patients (35%) presented a moderate VE, and a large VE was detected in 1 patient (4%). No statistically significant difference in detection of VE was found among the three tests (p = 0.472). TRUS and CEUS are able to provide information about the integrity of the VUA that is comparable with that of CG. Copyright © 2013 S. Karger AG, Basel.

  11. Preparation of protamine cationic nanobubbles and experimental study of their physical properties and in vivo contrast enhancement.

    PubMed

    Tong, Hai-Peng; Wang, Luo-Fu; Guo, Yan-Li; Li, Lang; Fan, Xiao-Zhou; Ding, Jun; Huang, Hai-Yun

    2013-11-01

    In this study, we aimed to prepare a novel type of microbubble (MB), protamine cationic nanobubble (NB), to provide a new vector for tumor gene therapy. We prepared cationic NBs with protamine and other lipid components using mechanical oscillation. The protamine cationic NBs had a mean diameter of 521.2 ± 37.57 nm, a zeta potential of +18.5 mV, and a gene-carrying capacity of 15.69 μg androgen receptor (AR) siRNA per 10(8) NBs. The cationic NBs exhibited superior contrast enhancement for in vivo imaging compared with SonoVue (Bracco, Geneva, Switzerland), and their physical properties did not change significantly after 1 wk; meanwhile, the transfection efficiency of the cationic NBs in androgen-independent prostate cancer cells mediated by ultrasound irradiation was better than that of liposomes (82.17 ± 7.4% vs. 55.04 ± 5.4%, p < 0.01). Therefore, the protamine cationic NB can be considered for use as a novel type of gene-loading MB for ultrasound imaging and MB-mediated gene therapy of tumors. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  12. Cancer survivors exhibit a different relationship between muscle strength and health-related quality of life/fatigue compared to healthy subjects.

    PubMed

    Morishita, S; Tsubaki, A; Fu, J B; Mitobe, Y; Onishi, H; Tsuji, T

    2018-05-16

    We investigated the difference in relationship between muscle strength and quality of life (QOL)/fatigue in long-term cancer survivors and healthy subjects. Thirty-six cancer survivors and 29 healthy subjects were assessed for body composition and bone status at the calcaneus using the Osteo Sono Assessment Index. Muscle strength was evaluated via handgrip and knee extensor strength. Health-related QOL was assessed using the Medical Outcome Study 36-item Short-Form Health Survey. Fatigue was measured using the brief fatigue inventory. Cancer survivors exhibited lower QOL scores in the physical functioning, physical role function, bodily pain and general health domains (p < .05). Grip and knee extension muscle strength in cancer survivors was positively correlated with the physical function and bodily pain of QOL (p < .05). The usual fatigue subscale score was only significantly higher in cancer survivors than in healthy subjects (p < .05). However, there were no correlations between muscle strength and fatigue in cancer survivors. Our results showed that muscle strength was an important factor for improving QOL in cancer survivors. We believe that the findings of this study will be relevant in the context of planning rehabilitation for cancer survivors. © 2018 John Wiley & Sons Ltd.

  13. FG Width Scalability of the 3-D Vertical FG NAND Using the Sidewall Control Gate (SCG)

    NASA Astrophysics Data System (ADS)

    Seo, Moon-Sik; Endoh, Tetsuo

    Recently, the 3-D vertical Floating Gate (FG) type NAND cell arrays with the Sidewall Control Gate (SCG), such as ESCG, DC-SF and S-SCG, are receiving attention to overcome the reliability issues of Charge Trap (CT) type device. Using this novel cell structure, highly reliable flash cell operations were successfully implemented without interference effect on the FG type cell. However, the 3-D vertical FG type cell has large cell size by about 60% for the cylindrical FG structure. In this point of view, we intensively investigate the scalability of the FG width of the 3-D vertical FG NAND cells. In case of the planar FG type NAND cell, the FG height cannot be scaled down due to the necessity of obtaining sufficient coupling ratio and high program speed. In contrast, for the 3-D vertical FG NAND with SCG, the FG is formed cylindrically, which is fully covered with surrounded CG, and very high CG coupling ratio can be achieved. As results, the scaling of FG width of the 3-D vertical FG NAND cell with S-SCG can be successfully demonstrated at 10nm regime, which is almost the same as the CT layer of recent BE-SONOS NAND.

  14. Physiologically Persistent Corpora lutea in Eurasian Lynx (Lynx lynx) – Longitudinal Ultrasound and Endocrine Examinations Intra-Vitam

    PubMed Central

    Painer, Johanna; Jewgenow, Katarina; Dehnhard, Martin; Arnemo, Jon M.; Linnell, John D. C.; Odden, John; Hildebrandt, Thomas B.; Goeritz, Frank

    2014-01-01

    Felids generally follow a poly-estrous reproductive strategy. Eurasian lynx (Lynx lynx) display a different pattern of reproductive cyclicity where physiologically persistent corpora lutea (CLs) induce a mono-estrous condition which results in highly seasonal reproduction. The present study was based around a sono-morphological and endocrine study of captive Eurasian lynx, and a control-study on free-ranging lynx. We verified that CLs persist after pregnancy and pseudo-pregnancy for at least a two-year period. We could show that lynx are able to enter estrus in the following year, while CLs from the previous years persisted in structure and only temporarily reduced their function for the period of estrus onset or birth, which is unique among felids. The almost constant luteal progesterone secretion (average of 5 ng/ml serum) seems to prevent folliculogenesis outside the breeding season and has converted a poly-estrous general felid cycle into a mono-estrous cycle specific for lynx. The hormonal regulation mechanism which causes lynx to have the longest CL lifespan amongst mammals remains unclear. The described non-felid like ovarian physiology appears to be a remarkably non-plastic system. The lynx's reproductive ability to adapt to environmental and anthropogenic changes needs further investigation. PMID:24599348

  15. Characterization of Different Microbubbles in Assisting Focused Ultrasound-Induced Blood-Brain Barrier Opening

    NASA Astrophysics Data System (ADS)

    Wu, Sheng-Kai; Chu, Po-Chun; Chai, Wen-Yen; Kang, Shih-Tsung; Tsai, Chih-Hung; Fan, Ching-Hsiang; Yeh, Chih-Kuang; Liu, Hao-Li

    2017-04-01

    Microbubbles (MBs) serve as a critical catalyst to amplify local cavitation in CNS capillary lumen to facilitate focused ultrasound (FUS) to transiently open the blood-brain barrier (BBB). However, limited understanding is available regarding the effect of different microbubbles to induce BBB opening. The aim of this study is to characterize different MBs on their effect in FUS-induced BBB opening. Three MBs, SonoVue, Definity, and USphere, were tested, with 0.4-MHz FUS exposure at 0.62-1.38 of mechanical index (MI) on rats. Evans blue, dynamic contrast-enhanced (DCE) MRI and small-animal ultrasound imaging were used as surrogates to allow molecule-penetrated quantification, BBB-opened observation, and MBs circulation/persistence. Cavitation activity was measured via the passive cavitation detection (PCD) setup to correlate with the exposure level and the histological effect. Under given and identical MB concentrations, the three MBs induced similar and equivalent BBB-opening effects and persistence. In addition, a treatment paradigm by adapting exposure time is proposed to compensate MB decay to retain the persistence of BBB-opening efficiency in multiple FUS exposures. The results potentially improve understanding of the equivalence among MBs in focused ultrasound CNS drug delivery, and provide an effective strategy for securing persistence in this treatment modality.

  16. EVALUATION OF CONTRAST-ENHANCED ULTRASONOGRAPHY AS A METHOD FOR DETECTING GALLBLADDER NECROSIS OR RUPTURE IN DOGS.

    PubMed

    Bargellini, Paolo; Orlandi, Riccardo; Paloni, Chiara; Rubini, Giuseppe; Fonti, Paolo; Peterson, Mark E; Rishniw, Mark; Boiti, Cristiano

    2016-11-01

    Gall bladder necrosis and rupture are life-threatening conditions in dogs requiring surgical intervention and early diagnosis is essential. Human patients with suspected gall bladder necrosis/rupture are commonly evaluated with contrast-enhanced ultrasonography (CEUS), however this procedure has not been described in dogs with suspected gall bladder necrosis/rupture. In a prospective diagnostic cohort study, CEUS (using SonoVue contrast medium) was performed in 93 dogs with gallbladder lesions identified by abdominal conventional ultrasonography. Necrosis/rupture was identified by CEUS as a focal lack of enhancement of the gallbladder wall. Dogs with positive CEUS finding for necrosis/rupture (complete lack of regional wall enhancement) underwent immediate surgery as did dogs with other biliary disorders requiring surgery. Dogs with negative CEUS findings or those not requiring surgery were managed medically. In cases undergoing surgery, necrosis/rupture was confirmed intraoperatively (and via histopathology). Absence of necrosis/rupture was confirmed either intraoperatively (via histopathology) or was assumed to be absent by complete recovery with medical management. Forty-nine dogs underwent surgery and cholecystectomy: 24 had necrosis/rupture. CEUS was more accurate (100% sensitive and specific) in diagnosing gallbladder wall necrosis/rupture than conventional ultrasonography (75% sensitive and 81% specific) (P < 0.03). In conclusion, CEUS provides accurate characterization of gallbladder wall integrity that can impact decisions regarding clinical management, either surgical or medical. © 2016 American College of Veterinary Radiology.

  17. Assessment of skeletal muscle microcirculation in type 2 diabetes mellitus using dynamic contrast-enhanced ultrasound: a pilot study.

    PubMed

    Amarteifio, Erick; Wormsbecher, Stephanie; Demirel, Serdar; Krix, Martin; Braun, Simone; Rehnitz, Christoph; Delorme, Stefan; Kauczor, Hans-Ulrich; Weber, Marc-André

    2013-09-01

    To investigate muscular micro-perfusion by employing dynamic contrast-enhanced ultrasound (CEUS) and performing transient arterial occlusion in patients with type 2 diabetes mellitus (DM-2). Twenty DM-2 patients (mean age, 58 ± 8.6 years; duration of diabetes, 15.4 ± 12.1 years) and 20 healthy volunteers (mean age, 54 ± 5.4 years) participated. CEUS was applied to the calf, while 4.8 mL of SonoVue(®) was injected intravenously. At the thigh level, arterial occlusion (60 s) was performed. CEUS parameters (tmax, max, AUCpost and m) were evaluated and Pearson-product-moment correlation coefficients were computed. A moderate negative correlation of HbA1c and max was established (-0.53). Max in patients with DM-2 >10 years was 79.89 ± 37.4. Max in patients with DM-2 duration <10 years was 137.62 ± 71.72 (p = 0.04). AUCpost in patients with DM-2 duration >10 years was 3924.01 ± 1630.52. AUCpost in patients with DM-2 duration <10 years was 6453.59 ± 3206.23 (p = 0.04). Patients with long history of DM-2 present with impaired muscular perfusion. CEUS and transient arterial occlusion may provide appropriate methods for semi-quantitative evaluation of muscular micro-perfusion in patients with DM-2.

  18. The Optimized Fabrication of Nanobubbles as Ultrasound Contrast Agents for Tumor Imaging.

    PubMed

    Cai, Wen Bin; Yang, Heng Li; Zhang, Jian; Yin, Ji Kai; Yang, Yi Lin; Yuan, Li Jun; Zhang, Li; Duan, Yun You

    2015-09-03

    Nanobubbles, which have the potential for ultrasonic targeted imaging and treatment in tumors, have been a research focus in recent years. With the current methods, however, the prepared uniformly sized nanobubbles either undergo post-formulation manipulation, such as centrifugation, after the mixture of microbubbles and nanobubbles, or require the addition of amphiphilic surfactants. These processes influence the nanobubble stability, possibly create material waste, and complicate the preparation process. In the present work, we directly prepared uniformly sized nanobubbles by modulating the thickness of a phospholipid film without the purification processes or the addition of amphiphilic surfactants. The fabricated nanobubbles from the optimal phospholipid film thickness exhibited optimal physical characteristics, such as uniform bubble size, good stability, and low toxicity. We also evaluated the enhanced imaging ability of the nanobubbles both in vitro and in vivo. The in vivo enhancement intensity in the tumor was stronger than that of SonoVue after injection (UCA; 2 min: 162.47 ± 8.94 dB vs. 132.11 ± 5.16 dB, P < 0.01; 5 min: 128.38.47 ± 5.06 dB vs. 68.24 ± 2.07 dB, P < 0.01). Thus, the optimal phospholipid film thickness can lead to nanobubbles that are effective for tumor imaging.

  19. The Optimized Fabrication of Nanobubbles as Ultrasound Contrast Agents for Tumor Imaging

    PubMed Central

    Cai, Wen Bin; Yang, Heng Li; Zhang, Jian; Yin, Ji Kai; Yang, Yi Lin; Yuan, Li Jun; Zhang, Li; Duan, Yun You

    2015-01-01

    Nanobubbles, which have the potential for ultrasonic targeted imaging and treatment in tumors, have been a research focus in recent years. With the current methods, however, the prepared uniformly sized nanobubbles either undergo post-formulation manipulation, such as centrifugation, after the mixture of microbubbles and nanobubbles, or require the addition of amphiphilic surfactants. These processes influence the nanobubble stability, possibly create material waste, and complicate the preparation process. In the present work, we directly prepared uniformly sized nanobubbles by modulating the thickness of a phospholipid film without the purification processes or the addition of amphiphilic surfactants. The fabricated nanobubbles from the optimal phospholipid film thickness exhibited optimal physical characteristics, such as uniform bubble size, good stability, and low toxicity. We also evaluated the enhanced imaging ability of the nanobubbles both in vitro and in vivo. The in vivo enhancement intensity in the tumor was stronger than that of SonoVue after injection (UCA; 2 min: 162.47 ± 8.94 dB vs. 132.11 ± 5.16 dB, P < 0.01; 5 min: 128.38.47 ± 5.06 dB vs. 68.24 ± 2.07 dB, P < 0.01). Thus, the optimal phospholipid film thickness can lead to nanobubbles that are effective for tumor imaging. PMID:26333917

  20. Solar photo-Fenton mineralization of antipyrine in aqueous solution.

    PubMed

    Durán, A; Monteagudo, J M; Sanmartín, I; Carrasco, A

    2013-11-30

    The mineralization of an aqueous solution of antipyrine (C11H12N2O), an emerging contaminant, using a solar photocatalytic oxidation process assisted with ferrioxalate was evaluated in a compound parabolic collector (CPC) pilot plant. Under the selected operating conditions ([H2O2] = 250 ppm, [Fe] = 14 ppm, pH = 2.7, and [(COOH)2·2H2O] = 80 ppm), 60% of TOC is removed just 5 min after treating an aqueous solution containing 50 ppm of antipyrine. The addition of oxalic acid up to a maximum concentration of 80 ppm significantly increases the mineralization rate during the first 15 min of the reaction. The synergism between the solar and dark H2O2/ferrioxalate process was quantified at 79%, calculated from the pseudo first-order mineralization rate constants. The operational costs due to the consumption of electrical energy, reagents and catalysts were calculated from the optimal conditions and compared with a novel sono-photocatalytic process using artificial UV-light. The results showed that the ferrioxalate-assisted solar photo-Fenton process was economically feasible, being able to achieve up to 60% mineralization with a total cost of 4.5 cent €/g TOC removed (1.1 €/m(3)). Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Modeling complicated rheological behaviors in encapsulating shells of lipid-coated microbubbles accounting for nonlinear changes of both shell viscosity and elasticity.

    PubMed

    Li, Qian; Matula, Thomas J; Tu, Juan; Guo, Xiasheng; Zhang, Dong

    2013-02-21

    It has been accepted that the dynamic responses of ultrasound contrast agent (UCA) microbubbles will be significantly affected by the encapsulating shell properties (e.g., shell elasticity and viscosity). In this work, a new model is proposed to describe the complicated rheological behaviors in an encapsulating shell of UCA microbubbles by applying the nonlinear 'Cross law' to the shell viscous term in the Marmottant model. The proposed new model was verified by fitting the dynamic responses of UCAs measured with either a high-speed optical imaging system or a light scattering system. The comparison results between the measured radius-time curves and the numerical simulations demonstrate that the 'compression-only' behavior of UCAs can be successfully simulated with the new model. Then, the shell elastic and viscous coefficients of SonoVue microbubbles were evaluated based on the new model simulations, and compared to the results obtained from some existing UCA models. The results confirm the capability of the current model for reducing the dependence of bubble shell parameters on the initial bubble radius, which indicates that the current model might be more comprehensive to describe the complex rheological nature (e.g., 'shear-thinning' and 'strain-softening') in encapsulating shells of UCA microbubbles by taking into account the nonlinear changes of both shell elasticity and shell viscosity.

  2. Modeling complicated rheological behaviors in encapsulating shells of lipid-coated microbubbles accounting for nonlinear changes of both shell viscosity and elasticity

    NASA Astrophysics Data System (ADS)

    Li, Qian; Matula, Thomas J.; Tu, Juan; Guo, Xiasheng; Zhang, Dong

    2013-02-01

    It has been accepted that the dynamic responses of ultrasound contrast agent (UCA) microbubbles will be significantly affected by the encapsulating shell properties (e.g., shell elasticity and viscosity). In this work, a new model is proposed to describe the complicated rheological behaviors in an encapsulating shell of UCA microbubbles by applying the nonlinear ‘Cross law’ to the shell viscous term in the Marmottant model. The proposed new model was verified by fitting the dynamic responses of UCAs measured with either a high-speed optical imaging system or a light scattering system. The comparison results between the measured radius-time curves and the numerical simulations demonstrate that the ‘compression-only’ behavior of UCAs can be successfully simulated with the new model. Then, the shell elastic and viscous coefficients of SonoVue microbubbles were evaluated based on the new model simulations, and compared to the results obtained from some existing UCA models. The results confirm the capability of the current model for reducing the dependence of bubble shell parameters on the initial bubble radius, which indicates that the current model might be more comprehensive to describe the complex rheological nature (e.g., ‘shear-thinning’ and ‘strain-softening’) in encapsulating shells of UCA microbubbles by taking into account the nonlinear changes of both shell elasticity and shell viscosity.

  3. Effect of ultrasonic waves on the water turbidity during the oxidation of phenol. Formation of (hydro)peroxo complexes.

    PubMed

    Villota, Natalia; Lomas, Jose M; Camarero, Luis M

    2017-11-01

    Analysis of the kinetics of aqueous phenol oxidation by a sono-Fenton process reveals that the via involving ortho-substituted intermediates prevails: catechol (25.0%), hydroquinone (7.7%) and resorcinol (0.6%). During the oxidation, water rapidly acquires color that reaches its maximum intensity at the maximum concentration of p-benzoquinone. Turbidity formation occurs at a slower rate. Oxidant dosage determines the nature of the intermediates, being trihydroxylated benzenes (pyrogallol, hydroxyhydroquinone) and muconic acid the main precursors causing turbidity. It is found that the concentration of iron species and ultrasonic waves affects the intensity of the turbidity. The pathway of (hydro)peroxo-iron(II) complexes formation is proposed. Operating with 20.0-27.8mgFe 2+ /kW rates leads to formation of (hydro)peroxo-iron(II) complexes, which induce high turbidity levels. These species would dissociate into ZZ-muconic acid and ferrous ions. Applying relationships around 13.9mgFe 2+ /kW, the formation of (hydro)peroxo-iron(III) complexes would occur, which could react with carboxylic acids (2,5-dioxo-3-hexenedioic acid). That reaction induces turbidity slower. This is due to the organic substrate reacting with two molecules of the (hydro)peroxo complex. Therefore, it is necessary to accelerate the iron regeneration, intensifying the ultrasonic irradiation. Afterwards, this complex would dissociate into maleic acid and ferric ions. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Neural analysis of bovine ovaries ultrasound images in the identification process of the corpus luteum

    NASA Astrophysics Data System (ADS)

    Górna, K.; Jaśkowski, B. M.; Okoń, P.; Czechlowski, M.; Koszela, K.; Zaborowicz, M.; Idziaszek, P.

    2017-07-01

    The aim of the paper is to shown the neural image analysis as a method useful for identifying the development stage of the domestic bovine corpus luteum on digital USG (UltraSonoGraphy) images. Corpus luteum (CL) is a transient endocrine gland that develops after ovulation from the follicle secretory cells. The aim of CL is the production of progesterone, which regulates many reproductive functions. In the presented studies, identification of the corpus luteum was carried out on the basis of information contained in ultrasound digital images. Development stage of the corpus luteum was considered in two aspects: just before and middle of domination phase and luteolysis and degradation phase. Prior to the classification, the ultrasound images have been processed using a GLCM (Gray Level Co-occurence Matrix). To generate a classification model, a Neural Networks module implemented in the STATISTICA was used. Five representative parameters describing the ultrasound image were used as learner variables. On the output of the artificial neural network was generated information about the development stage of the corpus luteum. Results of this study indicate that neural image analysis combined with GLCM texture analysis may be a useful tool for identifying the bovine corpus luteum in the context of its development phase. Best-generated artificial neural network model was the structure of MLP (Multi Layer Perceptron) 5:5-17-1:1.

  5. Spatiotemporal evolution of cavitation dynamics exhibited by flowing microbubbles during ultrasound exposure.

    PubMed

    Choi, James J; Coussios, Constantin-C

    2012-11-01

    Ultrasound and microbubble-based therapies utilize cavitation to generate bioeffects, yet cavitation dynamics during individual pulses and across consecutive pulses remain poorly understood under physiologically relevant flow conditions. SonoVue(®) microbubbles were made to flow (fluid velocity: 10-40 mm/s) through a vessel in a tissue-mimicking material and were exposed to ultrasound [frequency: 0.5 MHz, peak-rarefactional pressure (PRP): 150-1200 kPa, pulse length: 1-100,000 cycles, pulse repetition frequency (PRF): 1-50 Hz, number of pulses: 10-250]. Radiated emissions were captured on a linear array, and passive acoustic mapping was used to spatiotemporally resolve cavitation events. At low PRPs, stable cavitation was maintained throughout several pulses, thus generating a steady rise in energy with low upstream spatial bias within the focal volume. At high PRPs, inertial cavitation was concentrated in the first 6.3 ± 1.3 ms of a pulse, followed by an energy reduction and high upstream bias. Multiple pulses at PRFs below a flow-dependent critical rate (PRF(crit)) produced predictable and consistent cavitation dynamics. Above the PRF(crit), energy generated was unpredictable and spatially biased. In conclusion, key parameters in microbubble-seeded flow conditions were matched with specific types, magnitudes, distributions, and durations of cavitation; this may help in understanding empirically observed in vivo phenomena and guide future pulse sequence designs.

  6. Comparison of sand-based water filters for point-of-use arsenic removal in China.

    PubMed

    Smith, Kate; Li, Zhenyu; Chen, Bohan; Liang, Honggang; Zhang, Xinyi; Xu, Ruifei; Li, Zhilin; Dai, Huanfang; Wei, Caijie; Liu, Shuming

    2017-02-01

    Contamination of groundwater wells by arsenic is a major problem in China. This study compared arsenic removal efficiency of five sand-based point-of-use filters with the aim of selecting the most effective filter for use in a village in Shanxi province, where the main groundwater source had arsenic concentration >200 μg/L. A biosand filter, two arsenic biosand filters, a SONO-style filter and a version of the biosand filter with nails embedded in the sand were tested. The biosand filter with embedded nails was the most consistent and effective under the study conditions, likely due to increased contact time between water and nails and sustained corrosion. Effluent arsenic was below China's standard of 50 μg/L for more than six months after construction. The removal rate averaged 92% and was never below 86%. In comparison, arsenic removal for the nail-free biosand filter was never higher than 53% and declined with time. The arsenic biosand filter, in which nails sit in a diffuser basin above the sand, performed better but effluent arsenic almost always exceeded the standard. This highlights the positive impact on arsenic removal of embedding nails within the top layer of biosand filter sand and the promise of this low-cost filtration method for rural areas affected by arsenic contamination. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Detection of vascularity in wrist tenosynovitis: power doppler ultrasound compared with contrast-enhanced grey-scale ultrasound.

    PubMed

    Klauser, Andrea S; Franz, Magdalena; Arora, Rohit; Feuchtner, Gudrun M; Gruber, Johann; Schirmer, Michael; Jaschke, Werner R; Gabl, Markus F

    2010-01-01

    We sought to assess vascularity in wrist tenosynovitis by using power Doppler ultrasound (PDUS) and to compare detection of intra- and peritendinous vascularity with that of contrast-enhanced grey-scale ultrasound (CEUS). Twenty-six tendons of 24 patients (nine men, 15 women; mean age ± SD, 54.4 ± 11.8 years) with a clinical diagnosis of tenosynovitis were examined with B-mode ultrasonography, PDUS, and CEUS by using a second-generation contrast agent, SonoVue (Bracco Diagnostics, Milan, Italy) and a low-mechanical-index ultrasound technique. Thickness of synovitis, extent of vascularized pannus, intensity of peritendinous vascularisation, and detection of intratendinous vessels was incorporated in a 3-score grading system (grade 0 to 2). Interobserver variability was calculated. With CEUS, a significantly greater extent of vascularity could be detected than by using PDUS (P < 0.001). In terms of peri- and intratendinous vessels, CEUS was significantly more sensitive in the detection of vascularization compared with PDUS (P < 0.001). No significant correlation between synovial thickening and extent of vascularity could be found (P = 0.089 to 0.097). Interobserver reliability was calculated to be excellent when evaluating the grading score (κ = 0.811 to 1.00). CEUS is a promising tool to detect tendon vascularity with higher sensitivity than PDUS by improved detection of intra- and peritendinous vascularity.

  8. Energetic balance in an ultrasonic reactor using focused or flat high frequency transducers.

    PubMed

    Hallez, L; Touyeras, F; Hihn, J Y; Klima, J

    2007-09-01

    In order to undertake irradiation of polymer blocks or films by ultrasound, this paper deals with the measurements of ultrasonic power and its distribution within the cell by several methods. The electric power measured at the transducer input is compared to the ultrasonic power input to the cell evaluated by calorimetry and radiation force measurement for different generator settings. Results obtained in the specific case of new transducer types (composites and focused composites i.e., HIFU: high intensity focused ultrasound) provide an opportunity to conduct a discussion about measurement methods. It has thus been confirmed that these measurement techniques can be applied to HIFU transducers. For all cases, results underlined the fact that measurement of radiation pressure for power evaluation is more adapted to low powers (<15 W) and that measurement by calorimetry is a valid technique for global energy measurements. Composites and monocomponent transducers were compared and it appears that the presence of an adaptation glass plate reduces the efficiency of the monocomponent transducers. The distribution of ultrasonic intensity is qualitatively depicted by sono-chemiluminescence of luminol. Finally, the quantity of energy absorbed by samples placed in the sound field is determined and the temperature distribution monitored as a function of wall distance. This energetic balance allows us to understand the global behaviour of all experimental set-ups made up of a generator-transducer-liquid and sample.

  9. Diffused sunlight driven highly synergistic pathway for complete mineralization of organic contaminants using reduced graphene oxide supported photocatalyst.

    PubMed

    Babu, Sundaram Ganesh; Ramalingam Vinoth; Neppolian, Bernaurdshaw; Dionysiou, Dionysios D; Ashokkumar, Muthupandian

    2015-06-30

    Diffused sunlight is found to be an effective light source for the efficient degradation and mineralization of organic pollutant (methyl orange as a probe) by sono-photocatalytic degradation using reduced graphene oxide (rGO) supported CuO-TiO2 photocatalyst. The prepared catalysts are characterized by XRD, XPS, UV-vis DRS, PL, photoelectrochemical, SEM-EDS and TEM. A 10 fold synergy is achieved for the first time by combining sonochemical and photocatalytic degradation under diffused sunlight. rGO loading augments the activity of bare CuO-TiO2 more than two fold. The ability of rGO in storing, transferring, and shuttling electrons at the heterojunction between TiO2 and CuO facilitates the separation of photogenerated electron-hole pairs, as evidenced by the photoluminescence results. The complete mineralization of MO and the by-products within a short span of time is confirmed by TOC analysis. Further, hydroxyl radical mediated degradation under diffused sunlight is confirmed by LC-MS. This system shows similar activity for the degradation of methylene blue and 4-chlorophenol indicating the versatility of the catalyst for the degradation of various pollutants. This investigation is likely to open new possibilities for the development of highly efficient diffused sunlight driven TiO2 based photocatalysts for the complete mineralization of organic contaminants. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Sono-synthesis of solar light responsive S-N-C-tri doped TiO2 photo-catalyst under optimized conditions for degradation and mineralization of Diclofenac.

    PubMed

    Ramandi, Sara; Entezari, Mohammad H; Ghows, Narjes

    2017-09-01

    C-N-S-tri doped TiO 2 anatase phase was synthesized using a facile, effective and novel sonochemical method at low frequency (20kHz) and at room temperature. Titanium butoxide as the titanium precursor and thiourea as the dopant source were used in the synthesis of the photo-catalyst. The effects of important parameters such as thiourea/Ti molar ratio, ultrasound intensity, sonication time and temperature were studied on the synthesis of tri-doped TiO 2 . The XPS results confirmed the presence of N, S, and C in the photo-catalyst. The photo-catalytic efficiency of the synthesized catalyst was studied toward the removal of Diclofenac as a model pharmaceutical organic pollutant. The results confirmed that the photo-catalyst synthesized with narrower band gap energy, shorter sonication time and higher ultrasound intensity leads to a rapid removal of Diclofenac. The effect of operational variables on the photo-catalytic activity of C-N-S tri doped TiO 2 nanoparticles was studied and optimized using the Taguchi method as a statistical technique. Additionally, the degradation process followed the pseudo-first-order kinetics model and the highest apparent rate constant of 0.0632min -1 achieved in 90min. Chemical oxygen demand (COD) analysis confirmed that the mineralization took place completely (100%) under the optimized conditions in 180min. Different scavengers were applied during the degradation process and active species such as OH and O 2 - had key roles in the photo-catalytic process. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Sono-leather technology with ultrasound: a boon for unit operations in leather processing - review of our research work at Central Leather Research Institute (CLRI), India.

    PubMed

    Sivakumar, Venkatasubramanian; Swaminathan, Gopalaraman; Rao, Paruchuri Gangadhar; Ramasami, Thirumalachari

    2009-01-01

    Ultrasound is a sound wave with a frequency above the human audible range of 16 Hz to 16 kHz. In recent years, numerous unit operations involving physical as well as chemical processes are reported to have been enhanced by ultrasonic irradiation. There have been benefits such as improvement in process efficiency, process time reduction, performing the processes under milder conditions and avoiding the use of some toxic chemicals to achieve cleaner processing. These could be a better way of augmentation for the processes as an advanced technique. The important point here is that ultrasonic irradiation is physical method activation rather than using chemical entities. Detailed studies have been made in the unit operations related to leather such as diffusion rate enhancement through porous leather matrix, cleaning, degreasing, tanning, dyeing, fatliquoring, oil-water emulsification process and solid-liquid tannin extraction from vegetable tanning materials as well as in precipitation reaction in wastewater treatment. The fundamental mechanism involved in these processes is ultrasonic cavitation in liquid media. In addition to this there also exist some process specific mechanisms for the enhancement of the processes. For instance, possible real-time reversible pore-size changes during ultrasound propagation through skin/leather matrix could be a reason for diffusion rate enhancement in leather processing as reported for the first time. Exhaustive scientific research work has been carried out in this area by our group working in Chemical Engineering Division of CLRI and most of these benefits have been proven with publications in valued peer-reviewed international journals. The overall results indicate that about 2-5-fold increase in the process efficiency due to ultrasound under the given process conditions for various unit operations with additional benefits. Scale-up studies are underway for converting these concepts in to a real viable larger scale operation. In the present paper, summary of our research findings from employing this technique in various unit operations such as cleaning, diffusion, emulsification, particle-size reduction, solid-liquid leaching (tannin and natural dye extraction) as well as precipitation has been presented.

  12. Diagnostic performance of power doppler and ultrasound contrast agents in early imaging-based diagnosis of organ-confined prostate cancer: Is it possible to spare cores with contrast-guided biopsy?

    PubMed

    Delgado Oliva, F; Arlandis Guzman, S; Bonillo García, M; Broseta Rico, E; Boronat Tormo, F

    2016-10-01

    To evaluate the diagnostic performance of gray scale transrectal ultrasound-B-mode US (BMUS), power Doppler (PDUS), and sonographic contrast (CEUS) in early imaging-based diagnosis of localized prostate cancer (PCa) and to compare the diagnostic profitability of randomized biopsy (RB), US-targeted prostate biopsy by means of PDUS and CEUS. A single-center, prospective, transversal, epidemiological study was conducted from January 2010 to January 2014. We consecutively included patients who an imaging study of the prostate with BMUS, PDUS, and CEUS was performed, followed by prostate biopsy due to clinical suspicion of prostate cancer (PSA 4-20ng/mL and/or rectal exam suggestive of malignancy). The diagnostic performance of BMUS, PDUS, and CEUS was determined by calculating the Sensitivity (S), Specificity (Sp), Predictive values (PV), and diagnostic odds ratio (OR) of the diagnosis tests and, for these variables, in the population general and based on their clinical stage according to rectal exam (cT1 and cT2). PCa detection rates determined by means of a randomized 10-core biopsy scheme were compared with detection rates of CEUS-targeted (SonoVue) 2-core biopsies. Of the initial 984 patients, US contrast SonoVue was administered to 179 (18.2%). The PCa detection rate by organ of BMUS/PDUS in the global population was 38% versus 43% in the subpopulation with CEUS. The mean age of the patients was 64.3±7.01years (95% CI, 63.75-64.70); mean total PSA was 8.9±3.61ng/mL (95% CI, 8.67-9.13) and the mean prostate volume was 56.2±29cc (95% CI, 54.2-58.1). The detection rate by organ of targeted biopsy with BMUS, PDUS, and CEUS were as follows: Global population (10.6, 8.2, 24.5%), stage cT1 (5.6, 4.2, 16.4%), and stage cT2 (32.4, 22.3, 43.5%). Comparing the detection rates of the CEUS-targeted biopsy and randomized biopsy, the following results were obtained: Global population (24.5% vs. 41.8%), stage cT1 (16% vs. 35%), and stage cT2 (43.5% vs. 66.6%), with a p value<0

  13. Role of acoustic radiation force impulse and shear wave velocity in prediction of preterm birth: a prospective study.

    PubMed

    Agarwal, Arjit; Agarwal, Shubhra; Chandak, Shruti

    2018-06-01

    Background Preterm birth is one of the important causes of neonatal morbidity where we rely on subjective criteria such as modified Bishop's scoring and contemporary sonographic measurement of cervical length. Acoustic radiation force impulse (ARFI) is a technological advancement in elastography that can be employed in prediction of cervical softening and preterm labor. Purpose To evaluate the role of ARFI technique and shear wave velocity (SWV) estimates as a predictor of preterm birth and its comparison with other clinical and sono-elastographic measures. Material and Methods Thirty-four pregnant women (gestation age = 28-37 weeks age) showing features suggestive of preterm labor were included and evaluated with modified Bishop's score, cervical length by ultrasound (US), ARFI to derive Elastography index (EI), and SWV of the cervix. The patients were later divided into two groups, using the clinical outcome of preterm or term delivery. Results Twenty patients delivered at term (gestational age > 37 weeks) and 14 were preterm. Receiver operating characteristics (ROC) curves showed SWV with highest sensitivity and specificity (93% and 90%, respectively) for the prediction of preterm birth at a cutoff value of 2.83 m/s. EI and modified Bishop's score were comparable to each other, but were less sensitive techniques. Conclusion Elastographic assessment of antenatal cervix is a novel technique of virtual palpation of internal os and can be utilized as an objective criterion for preterm birth prediction.

  14. HematoPorphyrin Monomethyl Ether polymer contrast agent for ultrasound/photoacoustic dual-modality imaging-guided synergistic high intensity focused ultrasound (HIFU) therapy

    NASA Astrophysics Data System (ADS)

    Yan, Sijing; Lu, Min; Ding, Xiaoya; Chen, Fei; He, Xuemei; Xu, Chunyan; Zhou, Hang; Wang, Qi; Hao, Lan; Zou, Jianzhong

    2016-08-01

    This study is to prepare a hematoporphyrin monomethyl ether (HMME)-loaded poly(lactic-co-glycolic acid) (PLGA) microcapsules (HMME/PLGA), which could not only function as efficient contrast agent for ultrasound (US)/photoacoustic (PA) imaging, but also as a synergistic agent for high intensity focused ultrasound (HIFU) ablation. Sonosensitizer HMME nanoparticles were integrated into PLGA microcapsules with the double emulsion evaporation method. After characterization, the cell-killing and cell proliferation-inhibiting effects of HMME/PLGA microcapsules on ovarian cancer SKOV3 cells were assessed. The US/PA imaging-enhancing effects and synergistic effects on HIFU were evaluated both in vitro and in vivo. HMME/PLGA microcapsules were highly dispersed with well-defined spherical morphology (357 ± 0.72 nm in diameter, PDI = 0.932). Encapsulation efficiency and drug-loading efficiency were 58.33 ± 0.95% and 4.73 ± 0.15%, respectively. The HMME/PLGA microcapsules remarkably killed the SKOV3 cells and inhibited the cell proliferation, significantly enhanced the US/PA imaging results and greatly enhanced the HIFU ablation effects on ovarian cancer in nude mice by the HMME-mediated sono-dynamic chemistry therapy (SDT). HMME/PLGA microcapsules represent a potential multifunctional contrast agent for HIFU diagnosis and treatment, which might provide a novel strategy for the highly efficient imaging-guided non-invasive HIFU synergistic therapy for cancers by SDT in clinic.

  15. HematoPorphyrin Monomethyl Ether polymer contrast agent for ultrasound/photoacoustic dual-modality imaging-guided synergistic high intensity focused ultrasound (HIFU) therapy

    PubMed Central

    Yan, Sijing; LU, Min; Ding, Xiaoya; Chen, Fei; He, Xuemei; Xu, Chunyan; Zhou, Hang; Wang, Qi; Hao, Lan; Zou, Jianzhong

    2016-01-01

    This study is to prepare a hematoporphyrin monomethyl ether (HMME)-loaded poly(lactic-co-glycolic acid) (PLGA) microcapsules (HMME/PLGA), which could not only function as efficient contrast agent for ultrasound (US)/photoacoustic (PA) imaging, but also as a synergistic agent for high intensity focused ultrasound (HIFU) ablation. Sonosensitizer HMME nanoparticles were integrated into PLGA microcapsules with the double emulsion evaporation method. After characterization, the cell-killing and cell proliferation-inhibiting effects of HMME/PLGA microcapsules on ovarian cancer SKOV3 cells were assessed. The US/PA imaging-enhancing effects and synergistic effects on HIFU were evaluated both in vitro and in vivo. HMME/PLGA microcapsules were highly dispersed with well-defined spherical morphology (357 ± 0.72 nm in diameter, PDI = 0.932). Encapsulation efficiency and drug-loading efficiency were 58.33 ± 0.95% and 4.73 ± 0.15%, respectively. The HMME/PLGA microcapsules remarkably killed the SKOV3 cells and inhibited the cell proliferation, significantly enhanced the US/PA imaging results and greatly enhanced the HIFU ablation effects on ovarian cancer in nude mice by the HMME-mediated sono-dynamic chemistry therapy (SDT). HMME/PLGA microcapsules represent a potential multifunctional contrast agent for HIFU diagnosis and treatment, which might provide a novel strategy for the highly efficient imaging-guided non-invasive HIFU synergistic therapy for cancers by SDT in clinic. PMID:27535093

  16. Objective diagnosis of arrested labor on transperineal ultrasound.

    PubMed

    Nishimura, Kazuaki; Yoshimura, Kazuaki; Kubo, Tatsuhiko; Hachisuga, Toru

    2016-07-01

    Recent developments in transperineal ultrasound imaging of the pelvis have prompted trials to objectively evaluate labor progression for labor management. We evaluated the accuracy of transperineal ultrasound in diagnosing arrest of labor. Transperineal ultrasound and digital pelvic examinations were performed simultaneously in 63 term laboring patients (singleton fetuses in cephalic presentation). We analyzed a total of 216 ultrasound images (Sonography Volume Computer Aided Display Labor [Sono VCAD Labor®] installed in Voluson E8 ultrasound). We examined the correlation between the three ultrasound parameters head direction (HD), progression distance (PD), and progression angle (PA), and digital pelvic examination findings during labor in a transvaginal delivery group and an arrested labor group. The coefficient of correlations between HD/PD/PA and cervical dilation/fetal station were 0.667/0.657/0.706 and 0.667/0.751/0.803, respectively. The three parameters had strong correlations with digital pelvic examination (P < 0.05). In the 11 cases (17%) of cesarean section due to arrested labor, the position of the fetal head was visually unchanged on sequential ultrasound images. According to receiver operating characteristic curves, the significant cut-offs for HD, PD, and PA for arrested labor were 105° (P = 0.048), 35 mm (P = 0.048), and 120° (P = 0.001), respectively. Transperineal ultrasound imaging is helpful for objective evaluation of labor progression and the diagnosis of arrested labor. © 2016 Japan Society of Obstetrics and Gynecology.

  17. Precise spatial control of cavitation erosion in a vessel phantom by using an ultrasonic standing wave.

    PubMed

    Shi, Aiwei; Huang, Peixuan; Guo, Shifang; Zhao, Lu; Jia, Yingjie; Zong, Yujin; Wan, Mingxi

    2016-07-01

    In atherosclerotic inducement in animal models, the conventionally used balloon injury is invasive, produces excessive vessel injuries at unpredictable locations and is inconvenient in arterioles. Fortunately, cavitation erosion, which plays an important role in therapeutic ultrasound in blood vessels, has the potential to induce atherosclerosis noninvasively at predictable sites. In this study, precise spatial control of cavitation erosion for superficial lesions in a vessel phantom was realised by using an ultrasonic standing wave (USW) with the participation of cavitation nuclei and medium-intensity ultrasound pulses. The superficial vessel erosions were restricted between adjacent pressure nodes, which were 0.87 mm apart in the USW field of 1 MHz. The erosion positions could be shifted along the vessel by nodal modulation under a submillimetre-scale accuracy without moving the ultrasound transducers. Moreover, the cavitation erosion of the proximal or distal wall could be determined by the types of cavitation nuclei and their corresponding cavitation pulses, i.e., phase-change microbubbles with cavitation pulses of 5 MHz and SonoVue microbubbles with cavitation pulses of 1 MHz. Effects of acoustic parameters of the cavitation pulses on the cavitation erosions were investigated. The flow conditions in the experiments were considered and discussed. Compared to only using travelling waves, the proposed method in this paper improves the controllability of the cavitation erosion and reduces the erosion depth, providing a more suitable approach for vessel endothelial injury while avoiding haemorrhage. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. HematoPorphyrin Monomethyl Ether polymer contrast agent for ultrasound/photoacoustic dual-modality imaging-guided synergistic high intensity focused ultrasound (HIFU) therapy.

    PubMed

    Yan, Sijing; Lu, Min; Ding, Xiaoya; Chen, Fei; He, Xuemei; Xu, Chunyan; Zhou, Hang; Wang, Qi; Hao, Lan; Zou, Jianzhong

    2016-08-18

    This study is to prepare a hematoporphyrin monomethyl ether (HMME)-loaded poly(lactic-co-glycolic acid) (PLGA) microcapsules (HMME/PLGA), which could not only function as efficient contrast agent for ultrasound (US)/photoacoustic (PA) imaging, but also as a synergistic agent for high intensity focused ultrasound (HIFU) ablation. Sonosensitizer HMME nanoparticles were integrated into PLGA microcapsules with the double emulsion evaporation method. After characterization, the cell-killing and cell proliferation-inhibiting effects of HMME/PLGA microcapsules on ovarian cancer SKOV3 cells were assessed. The US/PA imaging-enhancing effects and synergistic effects on HIFU were evaluated both in vitro and in vivo. HMME/PLGA microcapsules were highly dispersed with well-defined spherical morphology (357 ± 0.72 nm in diameter, PDI = 0.932). Encapsulation efficiency and drug-loading efficiency were 58.33 ± 0.95% and 4.73 ± 0.15%, respectively. The HMME/PLGA microcapsules remarkably killed the SKOV3 cells and inhibited the cell proliferation, significantly enhanced the US/PA imaging results and greatly enhanced the HIFU ablation effects on ovarian cancer in nude mice by the HMME-mediated sono-dynamic chemistry therapy (SDT). HMME/PLGA microcapsules represent a potential multifunctional contrast agent for HIFU diagnosis and treatment, which might provide a novel strategy for the highly efficient imaging-guided non-invasive HIFU synergistic therapy for cancers by SDT in clinic.

  19. [Cyberstalking among Italian nurses: a large multicentric study].

    PubMed

    Comparcini, Dania; Simonetti, Valentina; Lupo, Roberto; Galli, Francesco; Bocij, Paul; Cicolini, Giancarlo

    2016-01-01

    Determinare la prevalenza di cyberstalking tra gli infermieri italiani e valutare il livello di ansia e depressione nelle vittime. Da aprile a settembre 2014 è stato condotto uno studio multicentrico trasversale in un campione di infermieri italiani (n=997) utilizzando il questionario "Cyberstalking" per analizzare il fenomeno del cyberstalking. Ai partecipanti, che si sono autodefinite vittime di cyberstalking, è stato chiesto anche di compilare gli strumenti "Beck Depression Inventory" e "State-Trait Anxiety Inventory" per valutare, rispettivamente, i livelli di depressione ed ansia. La prevalenza di cyberstalking tra gli infermieri italiani è risultata pari al 23.3%. Il 42.7% ha dovuto cambiare il proprio stile di vita e lavorativo. Il cyberstalker era prevalentemente di sesso maschile (52%) e, nel 49% dei casi, era un paziente. Le vittime hanno riferito moderati livelli di ansia (media=28.4, SD=23.2) e depressione (media=92.7, SD=18.3); i risultati hanno mostrato un aumento dei livelli di depressione negli infermieri esperti nell'utilizzo del computer, gestori di siti web o blog, e una correlazione negativa tra il livello di ansia e gli infermieri esperti (r = -0.264). Il cyberstalking è un fenomeno che si riscontra frequentemente tra gli infermieri. Il rapporto infermiere - paziente gioca un ruolo centrale nello sviluppo del fenomeno e le vittime hanno riferito disordini correlati allo stress che influenzano la vita lavorativa. Questi risultati preliminari potrebbero sensibilizzare, i dirigenti ospedalieri, la politica e i centri antiviolenza al fine di sviluppare strategie risolutiv.

  20. Effect of Ni doping on structural and optical properties of Zn{sub 1−x}Ni{sub x}O nanopowder synthesized via low cost sono-chemical method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Budhendra, E-mail: bksingh@ua.pt; Kaushal, Ajay, E-mail: ajay.kaushal@ua.pt; Bdikin, Igor

    2015-10-15

    Highlights: • Pure and Ni doped ZnO nanopowders were synthesized by low cost sonochemical method. • The optical properties of Zn{sub 1−x}Ni{sub x}O nanopowders can be tuned by varying Ni content. • The results reveal the solubility limit of Ni into ZnO matrix as below 8%. - Abstract: Zn{sub 1−x}Ni{sub x}O nanopowders with different Ni contents of x = 0.0, 0.04 and 0.08 were synthesized via cost effective sonochemical reaction method. X-ray diffraction (XRD) pattern reveals pure wurtzite phase of prepared nanostructures with no additional impurity peaks. The morphology and dimensions of nanoparticles were investigated using scanning electron microscope (SEM).more » A sharp and strong peak for first order optical mode for wurtzite zinc oxide (ZnO) structure was observed at ∼438 cm{sup −1} in Raman spectra. The calculated optical band gap (E{sub g}) from UV–vis transmission data was found to decrease with increase in Ni content. The observed red shift in E{sub g} with increasing Ni content in ZnO nanopowders were in agreement with band gap behaviours found in their photoluminescence (PL) spectra. The synthesised ZnO nanopowders with controlled band gap on Ni doping reveals their potential for use in various electronic and optical device applications. The results were discussed in detail.« less

  1. A randomised trial of the analgesic efficacy of ultrasound-guided transversus abdominis plane block after caesarean delivery under general anaesthesia.

    PubMed

    Tan, Terry T; Teoh, Wendy H L; Woo, David C M; Ocampo, Cecilia E; Shah, Mukesh K; Sia, Alex T H

    2012-02-01

    Previous studies examining the efficacy of transversus abdominis plane block after caesarean section have mostly been in parturients under spinal anaesthesia. We postulated that the advantage of performing transversus abdominis plane block after caesarean section might be even more obvious after general anaesthesia, resulting in reduced 24-h consumption of morphine. DESIGN, SETTING, PATIENTS AND INTERVENTIONS: In this single centre, randomised double-blind controlled trial, 40 women who underwent caesarean delivery under general anaesthesia were allocated randomly to receive a transversus abdominis plane block or no block. In those who received the block, 20 ml of levobupivacaine 2.5 mg ml was deposited bilaterally into the transversus abdominis plane under ultrasound guidance using a Sonosite Titan (SonoSite, Bothell, Washington, USA) 7-13 MHz linear transducer at the end of surgery when the patient was still anaesthetised. We recorded patient-controlled intravenous morphine use for 24 h, pain scores at rest and activity, sedation, nausea and vomiting, use of antiemetic medication and overall maternal satisfaction. The primary outcome was 24-h morphine consumption. Patients who received the transversus abdominis plane block used significantly less morphine in 24 h than those in the control group [12.3 (2.6) vs. 31.4 mg (3.1), P<0.001) and had higher satisfaction scores [16 (80%) vs. 5 (25%), P = 0.012). There were no differences between groups in the visual analogue pain scores, sedation level, nausea and vomiting or the use of antiemetic medication. Ultrasound-guided transversus abdominis plane block reduced morphine consumption following caesarean section under general anaesthesia, with increased maternal satisfaction.

  2. Approaches for Sustainable Mitigation of Arsenic Calamity in Bangladesh: Search for Safe Drinking Water

    NASA Astrophysics Data System (ADS)

    Alauddin, M.; Bhattacharjee, M.; Zakaria, A. B.; Rahman, M. M.; Seraji, M. S.

    2008-05-01

    Arsenic contamination of groundwater in Gangetic plain of Bihar, West Bengal in India and Bengal delta plain Bangladesh is shaping up as the greatest environmental health disaster in the current century. About 450 million combined population in these regions are at risk of developing adverse health effects due to arsenic contamination in groundwater. For an effective and sustainable mitigation, it is essential that we improve our understanding of fundamental processes of arsenic mobilization in sediments, biogeochemistry of arsenic in aquifer sediments and weigh a wide range of options for arsenic safe water for the vast population. In this paper, aspects of arsenic removal technology from groundwater in affected areas, sustainable development of household water filtration systems, deep aquifer water as potential arsenic safe water will be presented. In addition, sustainable development of water purification systems such as pond sand filtration (PSF), river sand filtration (RSF), rain water harvesting (RWH), dug well and their acceptability by the community will be discussed. A recent development of indigenous technology by local masons involves searching safe water through bore hole sediment color. The viability of this option in certain areas of Bangladesh will be discussed. Also, one of the household filtration systems approved by the government and locally known as SONO filter was recognized recently by the National Academy of Engineering -Grainger Challenge Prize for sustainability. Over 30, 000 of this unit were deployed in arsenic affected areas of Bangladesh. The affordability, ease of maintenance, social acceptability and environmental friendliness of all options will be addressed in the presentation.

  3. Cumulative phase delay imaging - A new contrast enhanced ultrasound modality

    NASA Astrophysics Data System (ADS)

    Demi, Libertario; van Sloun, Ruud J. G.; Wijkstra, Hessel; Mischi, Massimo

    2015-10-01

    Recently, a new acoustic marker for ultrasound contrast agents (UCAs) has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental pressure wave field components is in fact observable for ultrasound propagating through UCAs. This phenomenon is absent in the case of tissue nonlinearity and is dependent on insonating pressure and frequency, UCA concentration, and propagation path length through UCAs. In this paper, ultrasound images based on this marker are presented. The ULA-OP research platform, in combination with a LA332 linear array probe (Esaote, Firenze Italy), were used to image a gelatin phantom containing a PVC plate (used as a reflector) and a cylindrical cavity measuring 7 mm in diameter (placed in between the observation point and the PVC plate). The cavity contained a 240 µL/L SonoVueO® UCA concentration. Two insonating frequencies (3 MHz and 2.5 MHz) were used to scan the gelatine phantom. A mechanical index MI = 0.07, measured in water at the cavity location with a HGL-0400 hydrophone (Onda, Sunnyvale, CA), was utilized. Processing the ultrasound signals backscattered from the plate, ultrasound images were generated in a tomographic fashion using the filtered back-projection method. As already observed in previous studies, significantly higher CPD values are measured when imaging at a frequency of 2.5 MHz, as compared to imaging at 3 MHz. In conclusion, these results confirm the applicability of the discussed CPD as a marker for contrast imaging. Comparison with standard contrast-enhanced ultrasound imaging modalities will be the focus of future work.

  4. Scienza dei servizi

    NASA Astrophysics Data System (ADS)

    Cavenago, Dario; Mezzanzanica, Mario

    I servizi sono oramai centrali nella vita sociale di ogni Paese. L'aspettativa di ogni attore sociale, sia esso cittadino/utente e/o istituzione, è quella di ricevere da uno scambio che ha alla base un servizio un contributo che si caratterizza per una qualità intrinseca. Il mantenimento di tale promessa richiede all'azienda erogatrice un forte coinvolgimento, nel disegno del servizio, degli utenti ed una capacità di gestione della conoscenza; ciò è particolarmente significativo per quei servizi che si caratterizzano per una forte personalizzazione o complessità progettuale. Disegnare un servizio, metterlo in produzione e gestirne l'erogazione ha una complessità variabile in base al grado di coinvolgimento dei destinati ed alle dimensioni critiche che esprimono le condizioni di fattibilità di un servizio di qualità appropriato alle attese degli utilizzatori. Ugualmente la globalizzazione dell'economia e la scarsità delle risorse ha portato l'attenzione, ai fini della sostenibilità delle condizioni sopra richiamate, di una ricerca di modelli e strumenti che permettano una valutazione e una standardizzazione dei processi di produzione ed erogazione secondo condizioni di economicità. Tali primi e sintetici elementi hanno condotto diversi attori istituzionali, grandi imprese ed università attraverso i loro centri di ricerca, ad una azione di riflessione sul grado di "ingegnerizzazione" dei processi sottesi alla erogazione dei servizi ed in particolare ai servizi che attuano le politiche dei grandi settori di base dell'economia di una Nazione: educazione, sanità, sociale, sviluppo infrastrutture ecc.

  5. Harmonic responses and cavitation activity of encapsulated microbubbles coupled with magnetic nanoparticles.

    PubMed

    Gu, Yuyang; Chen, Chuyi; Tu, Juan; Guo, Xiasheng; Wu, Hongyi; Zhang, Dong

    2016-03-01

    Encapsulated microbubbles coupled with magnetic nanoparticles, one kind of hybrid agents that can integrate both ultrasound and magnetic resonance imaging/therapy functions, have attracted increasing interests in both research and clinic communities. However, there is a lack of comprehensive understanding of their dynamic behaviors generated in diagnostic and therapeutic applications. In the present work, a hybrid agent was synthesized by integrating superparamagnetic iron oxide nanoparticles (SPIOs) into albumin-shelled microbubbles (named as SPIO-albumin microbubbles). Then, both the stable and inertial cavitation thresholds of this hybrid agent were measured at varied SPIO concentrations and ultrasound parameters (e.g., frequency, pressure amplitude, and pulse length). The results show that, at a fixed acoustic driving frequency, both the stable and inertial cavitation thresholds of SPIO-albumin microbubble should decrease with the increasing SPIO concentration and acoustic driving pulse length. The inertial cavitation threshold of SPIO-albumin microbubbles also decreases with the raised driving frequency, while the minimum sub- and ultra-harmonic thresholds appear at twice and two thirds resonance frequency, respectively. It is also noticed that both the stable and inertial cavitation thresholds of SonoVue microbubbles are similar to those measured for hybrid microbubbles with a SPIO concentration of 114.7 μg/ml. The current work could provide better understanding on the impact of the integrated SPIOs on the dynamic responses (especially the cavitation activities) of hybrid microbubbles, and suggest the shell composition of hybrid agents should be appropriately designed to improve their clinical diagnostic and therapeutic performances of hybrid microbubble agents. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Novel fluorescence nanobubbles for contrast-enhanced ultrasound imaging in rabbit VX2 hepatocellular carcinoma model

    NASA Astrophysics Data System (ADS)

    Yu, Houqiang; Wang, Wei; He, Xiaoling; Zhou, Qibing; Ding, Mingyue

    2017-03-01

    Ultrasound contrast agents (UCAs) such as SonoVue or Optison have been used widely in clinic for contrast-enhanced vascular imaging. However, microbubbles UCAs display limitations in tumor-targeted imaging due to the large sizes, nanoscaled UCAs has consequently attracted increasing attentions. In this work, we synthesized nanobubbles (NBs) by ultrasonic cavitation method, then a fluorescent marker of Alexa Fluor 680 was conjugated to the shell in order to observe the localization of NBs in tumor tissue. Measurement of fundamental characteristics showed that the NBs had homogeneous distribution of mean diameter of 267.9 +/- 19.2 nm and polydispersity index of 0.410 +/- 0.056. To assess in vivo tumor-selectivity of NBs, we established the rabbits VX2 hepatocellular carcinoma model though surgical implantation method. After the rabbits were intravenous administered of NBs, contrast-enhanced sonograms was observed in the surrounding of VX2 tumor, which showed there are rich capillaries in the tumor periphery. We additionally investigated the toxic of the NBs by hematoxylin-eosin staining. The results indicated that the NBs is a biocompatible non-toxic lipid system. Furthermore, the VX2 tumors and major organs were analyzed using ex vivo fluorescence imaging to confirm the targeted selectivity of NBs, and the results verified that the NBs were capable of targeting VX2 tumor. Confocal laser scanning microscopy examination showed that the NBs can traverse the VX2 tumor capillaries and target to the hepatocellular carcinoma tumor cells. All these results suggested that the newly prepared NBs have a potential application in molecular imaging and tumor-targeting therapy.

  7. Dual-high-frequency ultrasound excitation on microbubble destruction volume.

    PubMed

    Shen, Che-Chou; Su, Shin-Yuan; Cheng, Chih-Hao; Yeh, Chih-Kuang

    2010-06-01

    The goal of this work was to test experimentally that exposing air bubbles or ultrasound contrast agents in water to amplitude modulated wave allows control of inertial cavitation affected volume and hence could limit the undesirable bioeffects. Focused transducer operating at the center frequency of 10 MHz and having about 65% fractional bandwidth was excited by 3 micros 8.5 and 11.5 MHz tone-bursts to produce 3 MHz envelope signal. The 3 MHz frequency was selected because it corresponds to the resonance frequency of the microbubbles used in the experiment. Another 5 MHz transducer was used as a receiver to produce B-mode image. Peak negative acoustic pressure was adjusted in the range from 0.5 to 3.5 MPa. The spectrum amplitudes obtained from the imaging of SonoVue contrast agent when using the envelope and a separate 3 MHz transducer were compared to determine their cross-section at the -6 dB level. The conventional 3 MHz tone-burst excitation resulted in the region of interest (ROI) cross-section of 2.47 mm while amplitude modulated, dual-frequency excitation with difference frequency of 3 MHz produced cross-section equal to 1.2mm. These results corroborate our hypothesis that, in addition to the considerably higher penetration depth of dual-frequency excitation due to the lower attenuation at 3 MHz than that at 8.5 and 11.5 MHz, the sample volume of dual-frequency excitation is also smaller than that of linear 3-MHz method for more spatially confined destruction of microbubbles. 2010 Elsevier B.V. All rights reserved.

  8. Automated flow quantification in valvular heart disease based on backscattered Doppler power analysis: implementation on matrix-array ultrasound imaging systems.

    PubMed

    Buck, Thomas; Hwang, Shawn M; Plicht, Björn; Mucci, Ronald A; Hunold, Peter; Erbel, Raimund; Levine, Robert A

    2008-06-01

    Cardiac ultrasound imaging systems are limited in the noninvasive quantification of valvular regurgitation due to indirect measurements and inaccurate hemodynamic assumptions. We recently demonstrated that the principle of integration of backscattered acoustic Doppler power times velocity can be used for flow quantification in valvular regurgitation directly at the vena contracta of a regurgitant flow jet. We now aimed to accomplish implementation of automated Doppler power flow analysis software on a standard cardiac ultrasound system utilizing novel matrix-array transducer technology with detailed description of system requirements, components and software contributing to the system. This system based on a 3.5 MHz, matrix-array cardiac ultrasound scanner (Sonos 5500, Philips Medical Systems) was validated by means of comprehensive experimental signal generator trials, in vitro flow phantom trials and in vivo testing in 48 patients with mitral regurgitation of different severity and etiology using magnetic resonance imaging (MRI) for reference. All measurements displayed good correlation to the reference values, indicating successful implementation of automated Doppler power flow analysis on a matrix-array ultrasound imaging system. Systematic underestimation of effective regurgitant orifice areas >0.65 cm(2) and volumes >40 ml was found due to currently limited Doppler beam width that could be readily overcome by the use of new generation 2D matrix-array technology. Automated flow quantification in valvular heart disease based on backscattered Doppler power can be fully implemented on board a routinely used matrix-array ultrasound imaging systems. Such automated Doppler power flow analysis of valvular regurgitant flow directly, noninvasively, and user independent overcomes the practical limitations of current techniques.

  9. Parametri, Variabili e altro: Un ripensamento su come questi concetti sono presentati in classe (Variable Parameters and Other Issues: A Review of How These Concepts Are Presented in Class).

    ERIC Educational Resources Information Center

    Chiarugi, Ivana; And Others

    1995-01-01

    This paper considers the problem of variables, in particular parameters, analyzes how these concepts are presented in textbooks, comments on paradigms of exercises in which parameters intervene, and points out difficulties encountered by students. Discusses results of teacher interviews concerning their dealing with parameters in class.…

  10. Sono-incorporation of CuO nanoparticles on the surface and into the mesoporous hexatitanate layers: Enhanced Fenton-like activity in degradation of orange-G at its neutral pH

    NASA Astrophysics Data System (ADS)

    Sehati, S.; Entezari, M. H.

    2017-03-01

    In this work, for the first time, CuO/Ti6O13 mesoporous nanocomposite was synthesized by direct intercalation of CuO nanoparticles into hexatitanate layers in the presence of ultrasound. In fact mesoporous potassium hexatitanate with high pore size (44.94 nm) was used as a support. CuO nanoparticles were grown into the titanate pores which caused formation of ultra small CuO with uniform size and high surface area. In fact, titanate is considered as a substrate for better dispersion and nucleation of the CuO nanoparticles which prevented the agglomeration and overgrowth of guest molecules. The prepared sample was characterized by XRD, FE-SEM, TEM, UV-vis spectra, N2 adsorption-desorption, Raman spectra and FT-IR techniques. The product was used as a heterogeneous Fenton-like catalyst for the degradation of Orang G (OG). The effect of important parameters, including pH, H2O2 addition rate and catalyst loading on the decolorization of OG were investigated. Based on the results, CuO/Ti6O13 catalyst exhibited high catalytic activity for OG degradation in aqueous solution at neutral pH of the dye. Moreover, breaking of H2O2 during the catalytic reaction was monitored by spectroscopic method. The results confirmed the decomposition of H2O2 to produce rad OH which is the main active species for the degradation of OG.

  11. Simultaneous Assessment of Myocardial Perfusion, Wall Motion, and Deformation during Myocardial Contrast Echocardiography: A Feasibility Study.

    PubMed

    Zoppellaro, Giacomo; Venneri, Lucia; Khattar, Rajdeep S; Li, Wei; Senior, Roxy

    2016-06-01

    Ultrasound contrast agents may be used for the assessment of regional wall motion and myocardial perfusion, but are generally considered not suitable for deformation analysis. The aim of our study was to assess the feasibility of deformation imaging on contrast-enhanced images using a novel methodology. We prospectively enrolled 40 patients who underwent stress echocardiography with continuous intravenous infusion of SonoVue for the assessment of myocardial perfusion imaging with flash replenishment technique. We compared longitudinal strain (Lε) values, assessed with a vendor-independent software (2D CPA), on 68 resting contrast-enhanced and 68 resting noncontrast recordings. Strain analysis on contrast recordings was evaluated in the first cardiac cycles after the flash. Tracking of contrast images was deemed feasible in all subjects and in all views. Contrast administration improved image quality and increased the number of segments used for deformation analysis. Lε of noncontrast and contrast-enhanced images were statistically different (-18.8 ± 4.5% and -22.8 ± 5.4%, respectively; P < 0.001), but their correlation was good (ICC 0.65, 95%CI 0.42-0.78). Patients with resting wall-motion abnormalities showed lower Lε values on contrast recordings (-18.6 ± 6.0% vs. -24.2 ± 5.5%, respectively; P < 0.01). Intra-operator and inter-operator reproducibility was good for both noncontrast and contrast images with no statistical differences. Our study shows that deformation analysis on postflash contrast-enhanced images is feasible and reproducible. Therefore, it would be possible to perform a simultaneous evaluation of wall-motion abnormalities, volumes, ejection fraction, perfusion defects, and cardiac deformation on the same contrast recording. © 2016, Wiley Periodicals, Inc.

  12. Synthesis and structural characterization of magnetic cadmium sulfide-cobalt ferrite nanocomposite, and study of its activity for dyes degradation under ultrasound

    NASA Astrophysics Data System (ADS)

    Farhadi, Saeed; Siadatnasab, Firouzeh

    2016-11-01

    Cadmium sulfide-cobalt ferrite (CdS/CFO) nanocomposite was easily synthesized by one-step hydrothermal decomposition of cadmium diethyldithiocarbamate complex on the CoFe2O4 nanoparticles at 200 °C. Spectroscopic techniques of powder X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FT-IR), UV-visible spectroscopy, field emission scanning electron microscopy (FESEM), energy-dispersive X-ray spectroscopy (EDX), Brunauer-Emmett-Teller (BET), and magnetic measurements were applied for characterizing the structure and morphology of the product. The results of FT-IR, XRD and EDX indicated that the CdS/CFO was highly pure. SEM and TEM results revealed that the CdS/CFO nanocomposite was formed from nearly uniform and sphere-like nanoparticles with the size of approximately 20 nm. The UV-vis absorption spectrum of the CdS/CFO nanocomposite showed the band gap of 2.21 eV, which made it suitable for sono-/photo catalytic purposes. By using the obtained CdS/CFO nanocomposite, an ultrasound-assisted advanced oxidation process (AOP) has been developed for catalytic degradation of methylene blue (MB), Rhodamine B (RhB), and methyl orange (MO)) in the presence of H2O2 as a green oxidant. CdS/CFO nanocomposite exhibited excellent sonocatalytic activity, so that, dyes were completely degraded in less than 10 min. The influences of crucial factors such as the H2O2 amount and catalyst dosage on the degradation efficiency were evaluated. The as-prepared CdS/CFO nanocomposite exhibited higher catalytic activity than pure CdS nanoparticles. Moreover, the magnetic property of CoFe2O4 made the nanocomposite recyclable.

  13. Ultrasound-mediated gene delivery of naked plasmid DNA in skeletal muscles: a case for bolus injections.

    PubMed

    Sanches, Pedro Gomes; Mühlmeister, Mareike; Seip, Ralf; Kaijzel, Eric; Löwik, Clemens; Böhmer, Marcel; Tiemann, Klaus; Grüll, Holger

    2014-12-10

    Localized gene delivery has many potential clinical applications. However, the nucleic acids (e.g. pDNA and siRNA) are incapable of passively crossing the endothelium, cell membranes and other biological barriers which must be crossed to reach their intracellular targets. A possible solution is the use of ultrasound to burst circulating microbubbles inducing transient permeabilization of surrounding tissues which mediates nucleic acid extravasation and cellular uptake. In this study we report on an optimization of the ultrasound gene delivery technique. Naked pDNA (200 μg) encoding luciferase and SonoVue® microbubbles were co-injected intravenously in mice. The hindlimb skeletal muscles were exposed to ultrasound from a non-focused transducer (1 MHz, 1.25 MPa, PRI 30s) and injection protocols and total amounts as well as ultrasound parameters were systemically varied. Gene expression was quantified relative to a control using a bioluminescence camera system at day 7 after sonication. Bioluminescence ratios in sonicated/control muscles of up to 101× were obtained. In conclusion, we were able to specifically deliver genetic material to the selected skeletal muscles and overall, the use of bolus injections and high microbubble numbers resulted in increased gene expression reflected by stronger bioluminescence signals. Based on our data, bolus injections seem to be required in order to achieve transient highly concentrated levels of nucleic acids and microbubbles at the tissue of interest which upon ultrasound exposure should lead to increased levels of gene delivery. Thus, ultrasound mediated gene delivery is a promising technique for the clinical translation of localized drug delivery. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. NOR-SASS (Norwegian Sonothrombolysis in Acute Stroke Study): Randomized Controlled Contrast-Enhanced Sonothrombolysis in an Unselected Acute Ischemic Stroke Population.

    PubMed

    Nacu, Aliona; Kvistad, Christopher E; Naess, Halvor; Øygarden, Halvor; Logallo, Nicola; Assmus, Jörg; Waje-Andreassen, Ulrike; Kurz, Kathinka D; Neckelmann, Gesche; Thomassen, Lars

    2017-02-01

    The NOR-SASS (Norwegian Sonothrombolysis in Acute Stroke Study) aimed to assess effect and safety of contrast-enhanced ultrasound treatment in an unselected acute ischemic stroke population. Patients treated with intravenous thrombolysis within 4.5 hours after symptom onset were randomized 1:1 to either contrast-enhanced sonothrombolysis (CEST) or sham CEST. A visible arterial occlusion on baseline computed tomography angiography was not a prerequisite for inclusion. Pulse-wave 2 MHz ultrasound was given for 1 hour and contrast (SonoVue) as an infusion for ≈30 minutes. Magnetic resonance imaging and angiography were performed after 24 to 36 hours. Primary study end points were neurological improvement at 24 hours defined as National Institutes of Health Stroke Scale score 0 or reduction of ≥4 National Institutes of Health Stroke Scale points compared with baseline National Institutes of Health Stroke Scale and favorable functional outcome at 90 days defined as modified Rankin scale score 0 to 1. A total of 183 patients were randomly assigned to either CEST (93 patient) or sham CEST (90 patients). The rates of symptomatic intracerebral hemorrhage, asymptomatic intracerebral hemorrhage, or mortality were not increased in the CEST group. Neurological improvement at 24 hours and functional outcome at 90 days was similar in the 2 groups both in the intention-to-treat analysis and in the per-protocol analysis. CEST is safe among unselected ischemic stroke patients with or without a visible occlusion on computed tomography angiography and with varying grades of clinical severity. There was, however, statistically no significant clinical effect of sonothrombolysis in this prematurely stopped trial. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01949961. © 2016 The Authors.

  15. Buccal mucosal graft urethroplasty in long segment anterior urethral stricture - is it gold standard?

    PubMed

    Kumar, Suresh; Bansal, Punit; Vijay, Mukesh K; Dutta, Arindam; Tiwari, Punit; Sharma, Pramod K; Goel, Amit; Bera, Malay K; Kundu, Anup K; Hazra, Avijit

    2013-01-01

    To assess the success of dorsal onlay buccal mucosal graft (BMG) urethroplasty in long segment anterior urethral stricture extending from external meatus to bulbar urethra). We studied 40 patients with long segment anterior urethral stricture, who underwent substitution urethroplasty using dorsal onlay BMG from January 2002 to December 2007. The patients were in the age range of 15-65 years (mean 35 years) in the LS group and 16-63 years (mean 34 years) in the non-lichen sclerosus (NLS) group. The cause of stricture was LS in 20 and NLS (inflammatory and idiopathic) in the other 20 patients. The mean stricture length was 14.5 cm (range 12-17 cm) in the LS group while it was 14.0 cm (range 12-16 cm) in the NLS group. The patients were evaluated with antegrade, retrograde urethrograms and sono-urethrograms and they were followed- up with uroflometery at three months for one year, then six- monthly for two years and then annually. The contrast studies were repeated at six-monthly intervals for one year and then annually for one year. Success was defined as normal voiding pattern without any intervention post-operatively. Median follow-up was 48 months (18-72 months) in the LS group, while it was 42 months (12-72 months) in the NLS group. Among the NLS group patients, three patients developed restricture on follow-up, while seven patients among the LS group developed restricture. We conclude that the high percentage of recurrence of strictures (35%) among the LS group renders BMG urethroplasty in long segment anterior urethral stricture an unacceptable solution, and it needs further study.

  16. Physical interpretation and development of ultrasonic nondestructive evaluation techniques applied to the quantitative characterization of textile composite materials

    NASA Technical Reports Server (NTRS)

    Miller, James G.

    1994-01-01

    In this Progress Report, we describe our continuing research activities concerning the development and implementation of advanced ultrasonic nondestructive evaluation methods applied to the inspection and characterization of complex composite structures. We explore the feasibility of implementing medical linear array imaging technology as a viable ultrasonic-based nondestructive evaluation method to inspect and characterize complex materials. As an initial step toward the application of linear array imaging technology to the interrogation of a wide range of complex composite structures, we present images obtained using an unmodified medical ultrasonic imaging system of two epoxy-bonded aluminum plate specimens, each with intentionally disbonded regions. These images are compared with corresponding conventional ultrasonic contact transducer measurements in order to assess whether these images can detect disbonded regions and provide information regarding the nature of the disbonded region. We present a description of a standoff/delay fixture which has been designed, constructed, and implemented on a Hewlett-Packard SONOS 1500 medical imaging system. This standoff/delay fixture, when attached to a 7.5 MHz linear array probe, greatly enhances our ability to interrogate flat plate specimens. The final section of this Progress Report describes a woven composite plate specimen that has been specially machined to include intentional flaws. This woven composite specimen will allow us to assess the feasibility of applying linear array imaging technology to the inspection and characterization of complex textile composite materials. We anticipate the results of this on-going investigation may provide a step toward the development of a rapid, real-time, and portable method of ultrasonic inspection and characterization based on linear array technology.

  17. Relationship between ultrasound estimated fetal gestational age and cerebellar appearance in healthy pregnant Nigerian women.

    PubMed

    Adeyekun, Ademola A; Orji, Michael O

    2015-01-01

    Fetal biometry by ultrasound provides reliable and important information about fetal growth and wellbeing. Evaluation of the fetal posterior fossa is useful in the assessment of neural tube-defects. Studies on normal ultrasound fetal cerebellar appearance and diameter across gestational age (GA) are scanty in the Nigerian medical literature. This study was carried out to study normal fetal cerebellar appearance and diameter at various GAs among healthy pregnant Nigerian Africans. This was a prospective study of 450 healthy singleton pregnant women between 13 and 42 weeks gestation. A curvilinear probe with a 3.5 MHz transducer of a SonoAce X6 (Medison Inc., Korea 2010) scanner was used to assess fetal transcerebellar diameter (TCD) and appearance. GA was also determined using fetal biometric parameters such as the biparietal diameter, femur length, and abdominal circumference. Fetal cerebellar appearance was correlated against GA. The cerebellar appearance was graded into: Grade I: 164 fetuses (36.4%), Grade II; 102 fetuses (22.7%) and Grade III: 184 fetuses (40.9%). Mean GA and TCD was 21 weeks and 21.2 mm for Grade I; 28 weeks and 32.6 mm for Grade II; and 35 weeks and 47.1 mm for Grade III. There was significance difference among the cerebellar grades at the GA groups and transverse cerebellar diameter (P < 0.000). There is a gradual and steady change in ultrasonographic appearance of the fetal cerebellar and diameter appearance with advancing gestation. The changes ranged from anechoic, "pair of eye glass" appearance at second trimester to relatively echogenic, "dumb-bell" appearance at early third trimester, and solid, "fan-shape" in late third trimester.

  18. Cumulative phase delay imaging - A new contrast enhanced ultrasound modality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demi, Libertario, E-mail: l.demi@tue.nl; Sloun, Ruud J. G. van; Mischi, Massimo

    Recently, a new acoustic marker for ultrasound contrast agents (UCAs) has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental pressure wave field components is in fact observable for ultrasound propagating through UCAs. This phenomenon is absent in the case of tissue nonlinearity and is dependent on insonating pressure and frequency, UCA concentration, and propagation path length through UCAs. In this paper, ultrasound images based on this marker are presented. The ULA-OP research platform, in combination with a LA332 linear array probe (Esaote, Firenze Italy), were used to image a gelatin phantom containing a PVC platemore » (used as a reflector) and a cylindrical cavity measuring 7 mm in diameter (placed in between the observation point and the PVC plate). The cavity contained a 240 µL/L SonoVueO{sup ®} UCA concentration. Two insonating frequencies (3 MHz and 2.5 MHz) were used to scan the gelatine phantom. A mechanical index MI = 0.07, measured in water at the cavity location with a HGL-0400 hydrophone (Onda, Sunnyvale, CA), was utilized. Processing the ultrasound signals backscattered from the plate, ultrasound images were generated in a tomographic fashion using the filtered back-projection method. As already observed in previous studies, significantly higher CPD values are measured when imaging at a frequency of 2.5 MHz, as compared to imaging at 3 MHz. In conclusion, these results confirm the applicability of the discussed CPD as a marker for contrast imaging. Comparison with standard contrast-enhanced ultrasound imaging modalities will be the focus of future work.« less

  19. Real time myocardial contrast echocardiography during supine bicycle stress and continuous infusion of contrast agent. Cutoff values for myocardial contrast replenishment discriminating abnormal myocardial perfusion.

    PubMed

    Miszalski-Jamka, Tomasz; Kuntz-Hehner, Stefanie; Schmidt, Harald; Hammerstingl, Christoph; Tiemann, Klaus; Ghanem, Alexander; Troatz, Clemens; Lüderitz, Berndt; Omran, Heyder

    2007-07-01

    Myocardial contrast echocardiography (MCE) is a new imaging modality for diagnosing coronary artery disease (CAD). The aim of our study was to evaluate feasibility of qualitative myocardial contrast replenishment (RP) assessment during supine bicycle stress MCE and find out cutoff values for such analysis, which could allow accurate detection of CAD. Forty-four consecutive patients, scheduled for coronary angiography (CA) underwent supine bicycle stress two-dimensional echocardiography (2DE). During the same session, MCE was performed at peak stress and post stress. Ultrasound contrast agent (SonoVue) was administered in continuous mode using an infusion pump (BR-INF 100, Bracco Research). Seventeen-segment model of left ventricle was used in analysis. MCE was assessed off-line in terms of myocardial contrast opacification and RP. RP was evaluated on the basis of the number of cardiac cycles required to refill the segment with contrast after its prior destruction with high-power frames. Determination of cutoff values for RP assessment was performed by means of reference intervals and receiver operating characteristic analysis. Quantitative CA was carried out using CAAS system. MCE could be assessed in 42 patients. CA revealed CAD in 25 patients. Calculated cutoff values for RP-analysis (peak-stress RP >3 cardiac cycles and difference between peak stress and post stress RP >0 cardiac cycles) provided sensitive (88%) and accurate (88%) detection of CAD. Sensitivity and accuracy of 2DE were 76% and 79%, respectively. Qualitative RP-analysis based on the number of cardiac cycles required to refill myocardium with contrast is feasible during supine bicycle stress MCE and enables accurate detection of CAD.

  20. In Search of the Optimal Heart Perfusion Ultrasound Imaging Platform.

    PubMed

    Grishenkov, Dmitry; Gonon, Adrian; Janerot-Sjoberg, Birgitta

    2015-09-01

    Quantification of myocardial perfusion by contrast echocardiography remains a challenge. Existing imaging phantoms used to evaluate the performance of ultrasound scanners do not comply with perfusion basics in the myocardium, where perfusion and motion are inherently coupled. To contribute toward an improvement, we developed a contrast echocardiographic perfusion imaging platform based on an isolated rat heart coupled to an ultrasound scanner. Perfusion was assessed by using 3 different types of contrast agents: dextran-based Promiten (Meda AB, Solna, Sweden), phospholipid-shelled SonoVue (Bracco Diagnostics, Inc, Princeton, NJ), and polymer-shelled MB-pH5-RT, developed in-house. The myocardial video intensity was monitored over time from contrast agent administration to peak, and 2 characteristic constants were calculated by using an exponential fit: A, representing capillary volume; and β, representing inflow velocity. Acquired experimental evidence demonstrates that the application of all 3 contrast agents allows sonographic estimation of myocardial perfusion in the isolated rat heart. Video intensity maps show that an increase in contrast concentration increases the late-plateau values, A, mimicking increased capillary volume. Estimated values of the flow, proportional to A × β, increase when the pressure of the perfusate column increases from 80 to 110 cm of water. This finding is in agreement with the true values of the coronary flow increase measured by a flowmeter attached to the aortic cannula. The contrast echocardiographic perfusion imaging platform described holds promise for standardized evaluation and optimization of contrast perfusion ultrasound imaging in which real-time inflow curves at low acoustic power semiquantitatively reflect coronary flow. © 2015 by the American Institute of Ultrasound in Medicine.

  1. Unenhanced and Contrast-Enhanced Ultrasonography During Hepatic Transarterial Embolization and Chemoembolization With Drug-Eluting Beads

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moschouris, Hippocrates, E-mail: hipmosch@gmail.co; Malagari, Katerina; Kornezos, Ioannis

    2010-12-15

    The purpose of this study was to describe and evaluate the findings of unenhanced ultrasonography (US) and contrast-enhanced ultrasonography (CEUS) when these modalities are applied during transarterial embolization (TAE) or transarterial chemoembolization (TACE) of liver tumors. Sixteen tumors (9 hepatocellular carcinomas, 5 metastases from colorectal cancer, and 2 hemangiomas) were treated with TAE with microspheres and/or TACE with drug-eluting beads. All of these lesions were studied with intraprocedural unenhanced US and 12 were studied with intraprocedural CEUS. For the latter, a second-generation echo-enhancer (SonoVue; Bracco, Milan, Italy) and a low mechanical index technique were used. Intraprocedural findings were classified accordingmore » to an arbitrary scale and were compared with pretreatment imaging (CEUS and computed tomography or CEUS and magnetic resonance imaging), with postembolization angiography, and with follow-up results. On unenhanced intraprocedural US, 13 of 16 tumors demonstrated intralesional high-level echoes of varying extent. These feature correlated poorly (r = 0.33, p = 0.097) with and generally underestimated the actual extent of necrosis. Exceptionally, high-level echoes that occupied the largest part of the treated lesions were associated with >50% tumor necrosis. Intraprocedural CEUS clearly depicted immediate partial or complete disappearance of tumor enhancement as a result of TAE/TACE. Three of 6 tumors with complete devascularization on postembolization angiogram showed residual enhancement on intraprocedural CEUS. Intraprocedural CEUS findings correlated closely (r = 0.91, p = 0.002) with follow-up findings. Intraprocedural sonography, particularly with echo-enhancers, could be used for intraprocedural monitoring in selected cases of liver tumors that undergo TAE or TACE.« less

  2. Therapy-related longitudinal brain perfusion changes in patients with chronic pelvic pain syndrome.

    PubMed

    Weisstanner, Christian; Mordasini, Livio; Thalmann, George N; Verma, Rajeev K; Rummel, Christian; Federspiel, Andrea; Kessler, Thomas M; Wiest, Roland

    2017-08-03

    The imaging method most frequently employed to identify brain areas involved in neuronal processing of nociception and brain pain perception is blood oxygenation level-dependent (BOLD) magnetic resonance imaging (MRI). Arterial spin labelling (ASL), in contrast, offers advantages when slow varying changes in brain function are investigated. Chronic pelvic pain syndrome (CPPS) is a disorder of, mostly, young males that leads to altered pain perceptions in structures related to the pelvis. We aimed to investigate the potential of ASL to monitor longitudinal cranial blood flow (CBF) changes in patients with CPPS. In a randomised, placebo-controlled, double-blind single centre trial, we investigated treatment effects in CPPS after 12 weeks in patients that underwent sono-electro-magnetic therapy vs placebo. We investigated changes of CBF related to treatment outcome using pseudo-continuous arterial spin labelling (pCASL)-MRI. We observed CBF downregulation in the prefrontal cortex and anterior cingulate cortex and upregulation in the dorsolateral prefrontal cortex in responders. Nonresponders presented with CBF upregulation in the hippocampus. In patients with a history of CPPS of less than 12 months, there were significant correlations between longitudinal CBF changes and the Chronic Prostatitis Symptom Index pain subscore within the joint clusters anterior cingulate cortex and left anterior prefrontal cortex in responders, and the right hippocampus in nonresponders. We demonstrated therapy-related and stimulus-free longitudinal CBF changes in core areas of the pain matrix using ASL. ASL may act as a complementary noninvasive method to functional MRI and single-photon emission computed tomography / positron emission tomography, especially in the longitudinal assessment of pain response in clinical trials.

  3. Contrast-enhanced harmonic endoscopic ultrasound in solid lesions of the pancreas: results of a pilot study.

    PubMed

    Napoleon, B; Alvarez-Sanchez, M V; Gincoul, R; Pujol, B; Lefort, C; Lepilliez, V; Labadie, M; Souquet, J C; Queneau, P E; Scoazec, J Y; Chayvialle, J A; Ponchon, T

    2010-07-01

    Distinguishing pancreatic adenocarcinoma from other pancreatic masses remains challenging with current imaging techniques. This prospective study aimed to evaluate the accuracy of a new procedure, imaging the microcirculation pattern of the pancreas by contrast-enhanced harmonic endoscopic ultrasound (CEH-EUS) with a new Olympus prototype echo endoscope. 35 patients presenting with solid pancreatic lesions were prospectively enrolled. All patients had conventional B mode and power Doppler EUS. After an intravenous bolus injection of 2.4 ml of a second-generation ultrasound contrast agent (SonoVue) CEH-EUS was then performed with a new Olympus prototype echo endoscope (xGF-UCT 180). The microvascular pattern was compared with the final diagnosis based on the pathological examination of specimens from surgery or EUS-guided fine-needle aspiration (EUS-FNA) or on follow-up for at least 12 months. The final diagnoses were: 18 adenocarcinomas, 9 neuroendocrine tumors, 7 chronic pancreatitis, and 1 stromal tumor. Power Doppler failed to display microcirculation, whereas harmonic imaging demonstrated it in all cases. Out of 18 lesions with a hypointense signal on CEH-EUS, 16 were adenocarcinomas. The sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), and accuracy of hypointensity for diagnosing pancreatic adenocarcinoma were 89 %, 88 %, 88 %, 89 %, and 88.5 %, compared with corresponding values of 72 %, 100 %, 77 %, 100 %, and 86 % for EUS-FNA. Of five adenocarcinomas with false-negative results at EUS-FNA, four had a hypointense echo signal at CEH-EUS. CEH-EUS with the new Olympus prototype device successfully visualizes the microvascular pattern in pancreatic solid lesions, and may be useful for distinguishing adenocarcinomas from other pancreatic masses.

  4. An assessment of the vulnerability of carotid plaques: a comparative study between intraplaque neovascularization and plaque echogenicity

    PubMed Central

    2013-01-01

    Background Carotid plaque echolucency as detected by Color Doppler ultrasonography (CDUS) has been used as a potential marker of plaque vulnerability. However, contrast-enhanced ultrasound (CEUS) has recently been shown to be a valuable method to evaluate the vulnerability and neovascularization within carotid atherosclerotic plaques. The aim of this study was to compare CEUS and CDUS in the assessment of plaque vulnerability using transcranial color Doppler (TCD) monitoring of microembolic signals (MES) as a reference technique. Methods A total of 46 subjects with arterial stenosis (≥ 50%) underwent a carotid duplex ultrasound, TCD monitoring of MES and CEUS (SonoVue doses of 2.0 mL) within a span of 3 days. The agreement between the CEUS, CDUS, and MES findings was assessed with a chi-square test. A p-value less than 0.05 was considered statistically significant. Results Neovascularization was observed in 30 lesions (44.4%). The vascular risk factors for stroke were similar and there were no age or gender differences between the 2 groups. Using CEUS, MES were identified in 2 patients (12.5%) within class 1 (non-neovascularization) as opposed to 15 patients (50.0%) within class 2 (neovascularization) (p = 0.023). CDUS revealed no significant differences in the appearance of the MES between the 2 groups (hyperechoic and hypoechoic) (p = 0.237). Conclusion This study provides preliminary evidence to suggest that intraplaque neovascularization detected by CEUS is associated with the presence of MESs, where as plaque echogenicity on traditional CDUS does not. These findings argue that CEUS may better identify high-risk plaques. PMID:23537052

  5. Gel pillow designed specifically for obstructive sleep apnea treatment with continuous positive airway pressure.

    PubMed

    Salvaggio, Adriana; Lo Bue, Anna; Isidoro, Serena Iacono; Romano, Salvatore; Marrone, Oreste; Insalaco, Giuseppe

    2016-01-01

    To determine whether the use of a gel pillow with side cutouts designed to accommodate a continuous positive airway pressure (CPAP) mask and reduce head temperature improves the efficacy of and adherence to auto-CPAP therapy. Twenty-three consecutive CPAP-naïve patients with obstructive sleep apnea were enrolled in the study. Patients were given an auto-CPAP machine with an appropriate CPAP mask and were instructed to use CPAP for 15 nights. They were instructed to sleep with their own pillow (the control pillow) from nights 1 to 5 and with either a foam pillow or a gel pillow, both of which had side cutouts, for 5 consecutive nights each, in random order. After night 15, auto-CPAP machine data were downloaded and patients rated their satisfaction with each pillow on a visual analog scale. Twenty-two patients completed the protocol. The pressures administered, residual apnea-hypopnea index, air leaks, and mean duration of CPAP use did not differ among the periods during which each pillow was used. Patients were significantly more satisfied with the gel pillow than with the control pillow and the foam pillow (p = 0.022 and p = 0.004, respectively), their level of satisfaction with the gel pillow correlating significantly with excessive daytime sleepiness (r2 = 0.19; p = 0.0443). Among obstructive sleep apnea patients treated with nasal CPAP, the use of a gel pillow with side cutouts appears to have no impact on treatment effectiveness. Nevertheless, such patients seem to prefer a gel pillow over other types of pillows. Determinar se o uso de um travesseiro de gel com recortes laterais para acomodar a máscara de continuous positive airway pressure (CPAP, pressão positiva contínua nas vias aéreas) e diminuir a temperatura em torno da cabeça melhora a eficácia do tratamento com auto-CPAP e a adesão dos pacientes ao tratamento. Foram incluídos no estudo 23 pacientes consecutivos com apneia obstrutiva do sono que nunca haviam recebido tratamento com CPAP. Os

  6. Capacity of mesoporous bioactive glass nanoparticles to deliver therapeutic molecules

    NASA Astrophysics Data System (ADS)

    El-Fiqi, Ahmed; Kim, Tae-Hyun; Kim, Meeju; Eltohamy, Mohamed; Won, Jong-Eun; Lee, Eun-Jung; Kim, Hae-Won

    2012-11-01

    Inorganic bioactive nanomaterials are attractive for hard tissue regeneration, including nanocomponents for bone replacement composites and nanovehicles for delivering therapeutics. Bioactive glass nanoparticles (BGn) have recently gained potential usefulness as bone and tooth regeneratives. Here we demonstrate the capacity of the BGn with mesopores to load and deliver therapeutic molecules (drugs and particularly genes). Spherical BGn with sizes of 80-90 nm were produced to obtain 3-5 nm sized mesopores through a sono-reacted sol-gel process. A simulated body fluid test of the mesoporous BGn confirmed their excellent apatite forming ability and the cellular toxicity study demonstrated their good cell viability up to 100 μg ml-1. Small molecules like chemical drug (Na-ampicillin) and gene (small interfering RNA; siRNA) were introduced as model drugs considering the mesopore size of the nanoparticles. Moreover, amine-functionalization allowed switchable surface charge property of the BGn (from -20-30 mV to +20-30 mV). Loading of ampicillin or siRNA saturated within a few hours (~2 h) and reflected the mesopore structure. While the ampicillin released relatively rapidly (~12 h), the siRNA continued to release up to 3 days with almost zero-order kinetics. The siRNA-nanoparticles were easily taken up by the cells, with a transfection efficiency as high as ~80%. The silencing effect of siRNA delivered from the BGn, as examined by using bcl-2 model gene, showed dramatic down-regulation (~15% of control), suggesting the potential use of BGn as a new class of nanovehicles for genes. This, in conjunction with other attractive properties, including size- and mesopore-related high surface area and pore volume, tunable surface chemistry, apatite-forming ability, good cell viability and the possible ion-related stimulatory effects, will potentiate the usefulness of the BGn in hard tissue regeneration.Inorganic bioactive nanomaterials are attractive for hard tissue regeneration

  7. Contrast-Enhanced Ultrasonography of Hepatocellular Carcinoma After Chemoembolisation Using Drug-Eluting Beads: A Pilot Study Focused on Sustained Tumor Necrosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moschouris, Hippocrates; Malagari, Katerina; Papadaki, Marina Georgiou

    The purpose of this study was to assess the use of contrast-enhanced ultrasonography (CEUS) and the sustained antitumor effect of drug-eluting beads used for transarterial chemoembolisation (TACE) of unresectable hepatocellular carcinoma (HCC). Ten patients with solitary, unresectable HCC underwent CEUS before, 2 days after, and 35 to 40 days after TACE using a standard dose (4 ml) of drug-eluting beads (DC Beads; Biocompatibles, Surrey, UK) preloaded with doxorubicin (25 mg doxorubicin/ml hydrated beads). For CEUS, a second-generation contrast agent (SonoVue, Bracco, Milan, Italy) and a low mechanical-index technique were used. A part of the tumor was characterized as necrotic ifmore » it showed complete lack of enhancement. The percentage of necrosis was calculated at the sonographic section that depicted the largest diameter of the tumor. Differences in the extent of early (2 days after TACE) and delayed (35 to 40 days after TACE) necrosis were quantitatively and subjectively assessed. Early post-TACE tumor necrosis ranged from 21% to 70% (mean 43.5% {+-} 19%). There was a statistically significant (p = 0.0012, paired Student t test) higher percentage of delayed tumor necrosis, which ranged from 24% to 88% (mean 52.3% {+-} 20.3%). Subjective evaluation showed a delayed obvious increase of the necrotic areas in 5 patients. In 2 patients, tumor vessels that initially remained patent disappeared on the delayed follow-up. A part of tumor necrosis after chemoembolisation of HCC with DEB seems to take place later than 2 days after TACE. CEUS may provide evidence for the sustained antitumor effect of DEB-TACE. Nevertheless, the ideal time for the imaging evaluation of tumor response remains to be defined.« less

  8. Correlations with operative anatomy of real time three-dimensional echocardiographic imaging of congenital aortic valvar stenosis.

    PubMed

    Sadagopan, Shankar N; Veldtman, Gruschen R; Sivaprakasam, Muthukumaran C; Keeton, Barry R; Gnanapragasam, James P; Salmon, Anthony P; Haw, Marcus P; Vettukattil, Joseph J

    2006-10-01

    To define the anatomic characteristics of the congenitally malformed and severely stenotic aortic valve using trans-thoracic real time three-dimensional echocardiography, and to compare and contrast this with the valvar morphology as seen at surgery. Prospective cross-sectional observational study. Tertiary centre for paediatric cardiology. All patients requiring aortic valvotomy between December 2003 and July 2004 were evaluated prior to surgery with three-dimensional echocardiography. Full volume loop images were acquired using the Phillips Sonos 7500 system. A single observer analysed the images using "Q lab 4.1" software. The details were then compared with operative findings. We identified 8 consecutive patients, with a median age of 16 weeks, ranging from 1 day to 11 years, with median weight of 7.22 kilograms, ranging from 2.78 to 22 kilograms. The measured diameter of the valvar orifice, and the number of leaflets identified, corresponded closely with surgical assessment. The sites of fusion of the leaflets were correctly identified by the echocardiographic imaging in all cases. Fusion between the right and non-coronary leaflets was identified in half the patients. Dysplasia was observed in 3 patients, with 1 patient having nodules and 2 shown to have excrescences. At surgery, nodules were excised, and excrescences were trimmed. The dysplastic changes correlated well with operative findings, though statistically not significant. We recommend trans-thoracic real time three-dimensional echocardiography for the assessment of the congenitally malformed aortic valve, particularly to identify sites of fusion between leaflets and to measure the orificial diameter. The definition of nodularity, and the prognosis of nodules based on the mode of intervention, will need a comparative study of patients submitted to balloon dilation as well as those undergoing surgical valvotomy.

  9. Sviluppi di Ricevitori E di Componentistica Per Banda 3 mm Ad INAF-OA Cagliari

    NASA Astrophysics Data System (ADS)

    Navarrini, Alessandro

    2017-11-01

    L'INAF-OA Cagliari (OACa) sta sviluppando un ricevitore criogenico a basso rumore basato su un mixer SSB (Single Side Band) a superconduttore SIS (Superconductor-Insulator-Superconductor) per la banda 3 mm. Il ricevitore, acquistato da IRAM, è stato fortemente modificato per essere adattato al fuoco Gregoriano di SRT (Sardinia Radio Telescope). Lo strumento è caratterizzato da una nuova criogenia a ciclo chiuso 4 K (per evitare l'uso di elio liquido in antenna), da un nuovo oscillatore locale (di tipo ALMA Banda 3) e da un nuovo sistema di controllo e di monitoraggio basato su schede Raspberry ed Arduino sviluppato ad OACa. Verranno presentati i recenti sviluppi sul ricevitore, inclusi i risultati preliminari della misura della temperatura di rumore, che raggiunge un valore pari a Trec=66 K alla frequenza di 86 GHz, nonostante la criogenia non sia ancora ottimizzata. L'INAF-OACa è coinvolto nel progetto AETHRA (Advanced European Technologies for Heterodyne Receivers for Astronomy) nel quadro del programma Radionet/Horizon2020 per il quale sta contribuendo al WP1 (Work Package 1). Lo scopo del WP1 è di sviluppare e costruire un dimostratore di un array di ricevitori a doppia polarizzazione per la banda 3 mm basato su amplificatori criogenici a basso rumore (LNA) in tecnologia a semiconduttore MMIC. Nell'ambito del WP1 l'OACa ha in carico il progetto di un OrthomodeTransducer (OMT) in guida d'onda o in tecnologia planare per la banda 72-116 GHz che sia integrabile con amplificatori MMICs ed adatto all'integrazione in un array da installare nel piano focale di un radiotelescopio. Verranno presentati i design preliminari degli OMT per AETHRA, che sono basati su prototipi sviluppati in passato da OACa.

  10. Effects of Fok-I polymorphism in vitamin D receptor gene on serum 25-hydroxyvitamin D, bone-specific alkaline phosphatase and calcaneal quantitative ultrasound parameters in young adults.

    PubMed

    Tanabe, Rieko; Kawamura, Yuka; Tsugawa, Naoko; Haraikawa, Mayu; Sogabe, Natsuko; Okano, Toshio; Hosoi, Takayuki; Goseki-Sone, Masae

    2015-01-01

    Several genes have been implicated as genetic determinants of osteoporosis. Vitamin D receptor (VDR) is an intracellular hormone receptor that specifically binds to the biologically active form of vitamin D, 1-alpha, 25- dihydroxyvitamin D3 [1, 25(OH)2D], and mediates its effects. One of the most frequently studied single nucleotide polymorphisms is the restriction fragment length polymorphism (RFLP) Fok-I (rs2228570). The presence of a Fok-I site, designated f, allows protein translation to initiate from the first ATG. An allele lacking the site (ATG>ACG: designated F), initiates from a second ATG site. In the present study, we explored the effect of the VDR Fok-I genotype on associations among serum bone-specific alkaline phosphatase (ALP), 25- hydroxyvitamin D3 [25(OH)D], 1, 25(OH)2D, and the dietary nutrient intake in healthy young Japanese subjects (n=193). Dietary nutrient intakes were calculated based on 3-day food records before the day of blood examinations. Quantitative ultrasound (QUS) parameters at the right calcaneus (heel bone) were measured. The allele frequencies were 0.622 for the F allele and 0.378 for the f allele in all subjects. Grouped by the VDR genotype, a significant positive correlation between the levels of serum bone-specific ALP and 25(OH)D was observed in the FF-type (p=0.005), but not in the ff-type. In addition, there was a significant positive correlation between the level of serum 25(OH)D and osteo-sono assessment index (OSI) in the FF-type (p=0.008), but not in the ff-type. These results suggest that the level of circulating 25(OH)D is an important factor when assessing the VDR Fok-I polymorphism to prevent osteoporosis.

  11. Contrast-Enhanced Ultrasound (CEUS) and Quantitative Perfusion Analysis in Patients with Suspicion for Prostate Cancer.

    PubMed

    Maxeiner, Andreas; Fischer, Thomas; Schwabe, Julia; Baur, Alexander Daniel Jacques; Stephan, Carsten; Peters, Robert; Slowinski, Torsten; von Laffert, Maximilian; Marticorena Garcia, Stephan Rodrigo; Hamm, Bernd; Jung, Ernst-Michael

    2018-06-06

     The aim of this study was to investigate contrast-enhanced ultrasound (CEUS) parameters acquired by software during magnetic resonance imaging (MRI) US fusion-guided biopsy for prostate cancer (PCa) detection and discrimination.  From 2012 to 2015, 158 out of 165 men with suspicion for PCa and with at least 1 negative biopsy of the prostate were included and underwent a multi-parametric 3 Tesla MRI and an MRI/US fusion-guided biopsy, consecutively. CEUS was conducted during biopsy with intravenous bolus application of 2.4 mL of SonoVue ® (Bracco, Milan, Italy). In the latter CEUS clips were investigated using quantitative perfusion analysis software (VueBox, Bracco). The area of strongest enhancement within the MRI pre-located region was investigated and all available parameters from the quantification tool box were collected and analyzed for PCa and its further differentiation was based on the histopathological results.  The overall detection rate was 74 (47 %) PCa cases in 158 included patients. From these 74 PCa cases, 49 (66 %) were graded Gleason ≥ 3 + 4 = 7 (ISUP ≥ 2) PCa. The best results for cancer detection over all quantitative perfusion parameters were rise time (p = 0.026) and time to peak (p = 0.037). Within the subgroup analysis (> vs ≤ 3 + 4 = 7a (ISUP 2)), peak enhancement (p = 0.012), wash-in rate (p = 0.011), wash-out rate (p = 0.007) and wash-in perfusion index (p = 0.014) also showed statistical significance.  The quantification of CEUS parameters was able to discriminate PCa aggressiveness during MRI/US fusion-guided prostate biopsy. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Ultrasonic contrast agents in transcranial perfusion sonography (TPS) for follow-up of patients with high grade gliomas.

    PubMed

    Ickenstein, G W; Valaikiene, J; Koch, H; Hau, P; Erban, P; Schlachetzki, F

    2008-04-01

    The aim of this study was to evaluate brain perfusion differences in patients with high grade gliomas after partial tumor resection and irradiation/chemotherapy between tumor and non-tumor hemisphere by transcranial perfusion sonography (TPS) employing a contrast burst imaging (CBI) technique. Six patients with glioblastoma (WHO Grade IV) in the temporoparietal region within the defined axial diencephalic scanning plane were examined by TPS during follow-up. All subjects had an adequate acoustic temporal bone window. Transtemporal insonation on brain tumor and non-tumor hemisphere was performed with a bolus-injection of sulphur hexafluoride-based contrast agent (10 mg i.v., 5mg/ml--SonoVue, Bracco, Altana, Switzerland). Recorded images were analysed off-line by Quanticon Software (3D-Echotech, Munich, Germany) and time intensity curve parameters [area under the curve (AUC, dB s), peak intensity (PI, dB), time to peak (TTP, s)] in five regions of interest (ROI) [thalamus anterior, thalamus posterior, nucleus lentiformis, white matter, whole hemisphere] were evaluated. Statistical analyses were performed. Perfusion differences between brain tumor and non-tumor hemispheres were detected with contrast burst imaging (CBI) technique with a significantly greater mean AUC (5343.69 dB s vs. 4625.04 dB s, p<0.028) and a significantly prolonged TTP (32.72 s vs. 28.91 s, p<0.046) in the tumor hemisphere. Within our study population, TTP and AUC seem to be the most robust parameters for the evaluation of cerebral perfusion differences assessed by transcranial perfusion sonography with CBI technique. We hypothesize that these results correlate with microvascular changes due to treatment regimens, such as microvessel necrosis after irradiation and chemotherapy. Above that, TPS may be of value for the long-term follow-up of brain tumor therapy concept.

  13. Quantitative Assessment of Free Flap Viability with CEUS Using an Integrated Perfusion Software.

    PubMed

    Geis, S; Klein, S; Prantl, L; Dolderer, J; Lamby, P; Jung, E-M

    2015-12-01

    New treatment strategies in oncology and trauma surgery lead to an increasing demand for soft tissue reconstruction with free tissue transfer. In previous studies, CEUS was proven to detect early flap failure. The aim of this study was to detect and quantify vascular disturbances after free flap transplantation using a fast integrated perfusion software tool. From 2011 to 2013, 33 patients were examined by one experienced radiologist using CEUS after a bolus injection of 1-2.4 ml of SonoVue(®). Flap perfusion was analysed qualitatively regarding contrast defects or delayed wash-in. Additionally, an integrated semi-quantitative analysis using time-intensity curve analysis (TIC) was performed. TIC analysis of the transplant was conducted on a centimetre-by-centimetre basis up to a penetration depth of 4 cm. The 2 perfusion parameters "Time to PEAK" and "Area under the Curve" were compared in patients without complications vs. patients with minor complications or complete flap loss to figure out significant differences. TtoPk is given in seconds (s) and Area is given in relative units (rU) Results: A regular postoperative process was observed in 26 (79%) patients. In contrast, 5 (15%) patients with partial superficial flap necrosis, 1 patient (3%) with complete flap loss and 1 patient (3%) with haematoma were observed. TtoPk revealed no significant differences, whereas Area revealed significantly lower perfusion values in the corresponding areas in patients with complications. The critical threshold for sufficient flap perfusion was set below 150 rU. In conclusion, CEUS is a mobile and cost-effective opportunity to quantify tissue perfusion and can even be used almost without any restrictions in multi-morbid patients with renal and hepatic failure. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Synthesis, characterization and electrocatalytic properties of delafossite CuGaO{sub 2}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmed, Jahangeer; Department of Chemistry, College of Science, King Saud University, Riyadh 11451; Mao, Yuanbing, E-mail: yuanbing.mao@utrgv.edu

    2016-10-15

    Delafossite CuGaO{sub 2} has been employed as photocatalysts for solar cells, but their electrocatalytic properties have not been extensively studied, especially no comparison among samples made by different synthesis routes. Herein, we first reported the successful synthesis of delafossite CuGaO{sub 2} particles with three different morphologies, i.e. nanocrystalline hexagons, sub-micron sized plates and micron–sized particles by a modified hydrothermal method at 190 °C for 60 h [1–3], a sono-chemical method followed by firing at 850 °C for 48 h, and a solid state route at 1150 °C, respectively. Morphology, composition and phase purity of the synthesized samples was confirmed bymore » powder X-ray diffraction and Raman spectroscopic studies, and then their electrocatalytic performance as active and cost effective electrode materials to the oxygen and hydrogen evolution reactions in 0.5 M KOH electrolyte versus Ag/AgCl was investigated and compared under the same conditions for the first time. The nanocrystalline CuGaO{sub 2} hexagons show enhanced electrocatalytic activity than the counterpart sub-micron sized plates and micron-sized particles. - Graphical abstract: Representative delafossite CuGaO2 samples with sub-micron sized plate and nanocrystalline hexagon morphologies accompanying with chronoamperometric voltammograms for oxygen evolution reaction and hydrogen evolution reaction in 0.5 M KOH electrolyte after purged with N{sub 2} gas. - Highlights: • Delafossite CuGaO{sub 2} with three morphologies has been synthesized. • Phase purity of the synthesized samples was confirmed. • Comparison on their electrocatalytic properties was made for the first time. • Their use as electrodes for oxygen and hydrogen evolution reactions was evaluated. • Nanocrystalline CuGaO{sub 2} hexagons show highest electrocatalytic activity.« less

  15. Is the area under blood pressure curve the best parameter to evaluate 24-h ambulatory blood pressure monitoring data?

    PubMed

    Nobre, Fernando; Mion, Décio

    2005-10-01

    Ambulatory blood pressure monitoring (ABPM) provides relevant data about blood pressure over a 24-h period. The analysis of parameters to determine the blood pressure profile from these data is of great importance. To calculate areas under systolic and diastolic blood pressure curves (SBP-AUC/DBP-AUC) and compare with systolic and diastolic blood pressure load (SBPL/DBPL) and 24-h systolic and diastolic blood pressure (24-h SBP/24-h DBP) in order to determine which provides the best correlation with left ventricular mass index (LVMI). ABPM measurements (1143 individuals) were analyzed to obtain 24-h SBP/24-h DBP, SBPL/DBPL, and SBP-AUC/ DBP-AUC, using Spacelabs (90207) and CardioSistemas devices. Left ventricular mass was determined using an echocardiograph HP Sonos 5500 and LVMI was calculated. The correlations between all possible pairs within the group 24-h SBP/SBPL/SBP-AUC and 24-h DBP/DBPL/DBP-AUC were high and statistically significant. The correlations between 24-h SBP/24-h DBP and SBP-AUC/DBP-AUC with SBPL/DBPL close to 100%, were lower than those mentioned above. The correlations of the parameters obtained by ABPM with LVMI were also high and statistically significant, except for blood pressure load between 90 and 100%, and for 24-h SBP of 135 mmHg or less and SBPL higher than 50%. SBPL/DBPL and SBP-AUC/DBP-AUC can be used for the evaluation of ABPM data owing to the strong correlation with 24-h SBP/24-h DBP and with LVMI, except when SBPL is close to 100% or 24-h SBP is below 135 mmHg but SBPL is above 50%. SBP-AUC/DBP-AUC, however, are a better alternative because they do not have the limitations of blood pressure load or even of 24-h blood pressure present.

  16. Potential value of contrast-enhanced intraoperative ultrasonography during partial hepatectomy for metastases: an essential investigation before resection?

    PubMed

    Leen, Edward; Ceccotti, Piercarlo; Moug, Susan J; Glen, Paul; MacQuarrie, John; Angerson, Wilson J; Albrecht, Thomas; Hohmann, Joachim; Oldenburg, Anja; Ritz, Jorg Peter; Horgan, Paul G

    2006-02-01

    The aim of the study was to assess the clinical value of contrast-enhanced intraoperative ultrasound (CE-IOUS) as a novel tool in the hepatic staging of patients undergoing liver resection. Sixty patients scheduled to undergo liver resection for metastatic disease were studied. Preoperative staging with contrast-enhanced CT and/or MR scans was performed within 2 to 6 weeks of operation. Following exploration, intraoperative ultrasound (IOUS) was performed using an HDI-5000 scanner (Philips) and a finger-probe with pulse inversion harmonic (PIH) capability. CE-IOUS in the PIH mode was performed in a standardized protocol (low MI: 0.02-0.04) after intravenous injection of 3-4 mL of SonoVue (Bracco spa, Milan); all detected lesions on precontrast and postcontrast scans were counted and mapped. Any alteration in surgical management was documented following CE-IOUS compared with IOUS. Three patients were excluded due to disseminated disease on exploration. CE-IOUS was significantly more sensitive than CT/MR and IOUS in detecting liver metastases (96.1% versus 76.7% and 81.5%, respectively) (P<0.05); it altered surgical management in 29.8% (17 of 57) of cases, due to 1) additional metastases in 19.3% (11 of 57), 2) less metastases in 3.5% (2 of 57), 3) benign lesions wrongly diagnosed as metastasis on IOUS/CT in 5.3% (3 of 57), and 4) vascular proximity in 1.8% (1 of 57). Management was unchanged in 70.2% (40 of 57) despite additional lesions detected in 3.5% (2 of 57) and benign lesion wrongly diagnosed on IOUS and CT as metastasis in 1.8% (1 of 57). CE-IOUS altered combined IOUS/CT/MR staging in 35.1%. These preliminary results suggest CE-IOUS is an essential tool prior to liver resection for metastases.

  17. [Linee guida italiane per il trattamento dell'alcolismo].

    PubMed

    Ceccanti, Mauro; Iannitelli, Angela; Fiore, Marco

    2018-01-01

    RIASSUNTO. L'Europa è la regione con il più forte consumo di alcol al mondo, con la più elevata percentuale di malattie totali e morti premature alcol-correlate. In Italia, questo fenomeno coinvolge circa il 13% della popolazione oltre i 18 anni e oltre il 25% dei pazienti ospedalizzati. Sfortunatamente, solo il 5% di questi pazienti vengono riconosciuti come persone affette da disturbo da uso di alcol (DUA). Una scarsa conoscenza della malattia, la mancanza di accesso alle cure e le poche risorse messe a disposizione nella gestione del problema sono tra le principali cause di ritardo nella diagnosi, alla fine con conseguenze cliniche molto più importanti e costose da gestire. Alla luce di ciò, abbiamo deciso di dedicare questo numero speciale della Rivista di psichiatria a una serie di articoli riguardanti le linee guida italiane per il trattamento della dipendenza da alcol. Realizzate in collaborazione con numerosi esperti e importanti società scientifiche italiane come il Centro di Riferimento Alcologico della Regione Lazio (CRARL), la Società Italiana Tossicodipendenze (SITD), la Società italiana per il Trattamento dell'Alcolismo e le sue Complicanze (SITAC), la Società Italiana Psichiatria delle Dipendenze (SIPDip), la Società Italiana Patologie da Dipendenza (SIPaD) e l'Istituto di Biologia Cellulare e Neurobiologia (IBCN-CNR), queste linee guida forniscono agli operatori una serie di raccomandazioni basate su prove di efficacia volte ad aumentare la conoscenza e un uso appropriato dei farmaci per le persone affette da DUA. Con la possibilità di un continuo aggiornamento, l'obiettivo principale di queste linee guida sarà quello di garantire l'omogeneità dei trattamenti e un incremento qualitativo nell'assistenza dei pazienti affetti da DUA, così da ridurre le conseguenze psicosociali e sulla salute pubblica di questa importante malattia psichiatrica.

  18. Analysis of the stability of housekeeping gene expression in the left cardiac ventricle of rats submitted to chronic intermittent hypoxia.

    PubMed

    Julian, Guilherme Silva; Oliveira, Renato Watanabe de; Tufik, Sergio; Chagas, Jair Ribeiro

    2016-01-01

    Obstructive sleep apnea (OSA) has been associated with oxidative stress and various cardiovascular consequences, such as increased cardiovascular disease risk. Quantitative real-time PCR is frequently employed to assess changes in gene expression in experimental models. In this study, we analyzed the effects of chronic intermittent hypoxia (an experimental model of OSA) on housekeeping gene expression in the left cardiac ventricle of rats. Analyses via four different approaches-use of the geNorm, BestKeeper, and NormFinder algorithms; and 2-ΔCt (threshold cycle) data analysis-produced similar results: all genes were found to be suitable for use, glyceraldehyde-3-phosphate dehydrogenase and 18S being classified as the most and the least stable, respectively. The use of more than one housekeeping gene is strongly advised. RESUMO A apneia obstrutiva do sono (AOS) tem sido associada ao estresse oxidativo e a várias consequências cardiovasculares, tais como risco aumentado de doença cardiovascular. A PCR quantitativa em tempo real é frequentemente empregada para avaliar alterações na expressão gênica em modelos experimentais. Neste estudo, analisamos os efeitos da hipóxia intermitente crônica (um modelo experimental de AOS) na expressão de genes de referência no ventrículo cardíaco esquerdo de ratos. Análises a partir de quatro abordagens - uso dos algoritmos geNorm, BestKeeper e NormFinder e análise de dados 2-ΔCt (ciclo limiar) - produziram resultados semelhantes: todos os genes mostraram-se adequados para uso, sendo que gliceraldeído-3-fosfato desidrogenase e 18S foram classificados como o mais e o menos estável, respectivamente. A utilização de mais de um gene de referência é altamente recomendada.

  19. Lumbar spondylosis, lumbar spinal stenosis, knee pain, back muscle strength are associated with the locomotive syndrome: Rural population study in Japan.

    PubMed

    Chiba, Daisuke; Tsuda, Eiichi; Wada, Kanichiro; Kumagai, Gentaro; Sasaki, Eiji; Nawata, Atsushi; Nakagomi, Sho; Takahashi, Ippei; Nakaji, Shigeyuki; Ishibashi, Yasuyuki

    2016-05-01

    To comprehensively investigate the clinical and physical factors associating with locomotive syndrome (Loc-S); the locomotorium-disability for daily life. 647 volunteers participated (247 males, 400 females, Age: 58.4 ± 11.0, BMI: 22.5 ± 3.3). Three self-assessment questionnaires were administered: 1) "25-question Geriatric Locomotive Function Scale" (GFLS-25) for evaluating Loc-S (GLFS-25 ≥ 16 defined as Loc-S); 2) "diagnostic support tool for LSS" (LSS-DST) for evaluating the prevalence of lumbar spinal stenosis (LSS); 3) Knee injury and Osteoarthritis Outcome Score (KOOS). Plain radiographs of the bilateral knees and lumbar spine were evaluated, and the severity of lumbar spondylosis (LS) and knee osteoarthritis (KOA) defined by Kellgren-Lawrence grade. Bone status was evaluated by using the osteo-sono assessment index (OSI) at the calcaneus. Isometric muscle strength of trunk and leg (Nm/kg, both extension and flexion) were evaluated. Linear regression analysis was performed to elucidate the factors concerned with GFLS-25 including age, sex, and BMI. Thirty-nine subjects (6.0%, 13 males, 26 females) were defined as having Loc-S. Single regression model showed that age, height, BMI, skeletal muscle mass, OSI, LSS, KOOS, the severity of LS and KOA, and trunk- and leg-muscle strength were correlated with the degree of GLFS-25. Stepwise multiple regression model showed that sex, height, LSS, KOOS, the severity of LS, and back muscle strength were significantly correlated with that of GLFS-25. In this cross-sectional study, pain status associated with LSS and knee joint, structural severity for LS, and back muscle strength primarily affected the degree of GFLS-25. For managing Loc-S, we must pay more intensive attention to these factors. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  20. Application of imaging fusion combining contrast-enhanced ultrasound and magnetic resonance imaging in detection of hepatic cellular carcinomas undetectable by conventional ultrasound.

    PubMed

    Dong, Yi; Wang, Wen-Ping; Mao, Feng; Ji, Zheng-Biao; Huang, Bei-Jian

    2016-04-01

    The aim of this study is to explore the value of volume navigation image fusion-assisted contrast-enhanced ultrasound (CEUS) in detection for radiofrequency ablation guidance of hepatocellular carcinomas (HCCs), which were undetectable on conventional ultrasound. From May 2012 to May 2014, 41 patients with 49 HCCs were included in this study. All lesions were detected by dynamic magnetic resonance imaging (MRI) and planned for radiofrequency ablation but were undetectable on conventional ultrasound. After a bolus injection of 2.4 ml SonoVue® (Bracco, Italy), LOGIQ E9 ultrasound system with volume navigation system (version R1.0.5, GE Healthcare, Milwaukee, WI, USA) was used to fuse CEUS and MRI images. The fusion time, fusion success rate, lesion enhancement pattern, and detection rate were analyzed. Image fusions were conducted successfully in 49 HCCs, the technical success rate was 100%. The average fusion time was (9.2 ± 2.1) min (6-12 min). The mean diameter of HCCs was 25.2 ± 5.3 mm (mean ± SD), and mean depth was 41.8 ± 17.2 mm. The detection rate of HCCs using CEUS/MRI imaging fusion (95.9%, 47/49) was significantly higher than CEUS (42.9%, 21/49) (P < 0.05). For small HCCs (diameter, 1-2 cm), the detection rate using imaging fusion (96.9%, 32/33) was also significantly higher than CEUS (18.2%, 6/33) (P < 0.01). All HCCs displayed a rapid wash-in pattern in the arterial phase of CEUS. Imaging fusion combining CEUS and MRI is a promising technique to improve the detection, precise localization, and accurate diagnosis of undetectable HCCs on conventional ultrasound, especially small and atypical HCCs. © 2015 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  1. Usefulness of myocardial parametric imaging to evaluate myocardial viability in experimental and in clinical studies

    PubMed Central

    Korosoglou, G; Hansen, A; Bekeredjian, R; Filusch, A; Hardt, S; Wolf, D; Schellberg, D; Katus, H A; Kuecherer, H

    2006-01-01

    Objective To evaluate whether myocardial parametric imaging (MPI) is superior to visual assessment for the evaluation of myocardial viability. Methods and results Myocardial contrast echocardiography (MCE) was assessed in 11 pigs before, during, and after left anterior descending coronary artery occlusion and in 32 patients with ischaemic heart disease by using intravenous SonoVue administration. In experimental studies perfusion defect area assessment by MPI was compared with visually guided perfusion defect planimetry. Histological assessment of necrotic tissue was the standard reference. In clinical studies viability was assessed on a segmental level by (1) visual analysis of myocardial opacification; (2) quantitative estimation of myocardial blood flow in regions of interest; and (3) MPI. Functional recovery between three and six months after revascularisation was the standard reference. In experimental studies, compared with visually guided perfusion defect planimetry, planimetric assessment of infarct size by MPI correlated more significantly with histology (r2  =  0.92 versus r2  =  0.56) and had a lower intraobserver variability (4% v 15%, p < 0.05). In clinical studies, MPI had higher specificity (66% v 43%, p < 0.05) than visual MCE and good accuracy (81%) for viability detection. It was less time consuming (3.4 (1.6) v 9.2 (2.4) minutes per image, p < 0.05) than quantitative blood flow estimation by regions of interest and increased the agreement between observers interpreting myocardial perfusion (κ  =  0.87 v κ  =  0.75, p < 0.05). Conclusion MPI is useful for the evaluation of myocardial viability both in animals and in patients. It is less time consuming than quantification analysis by regions of interest and less observer dependent than visual analysis. Thus, strategies incorporating this technique may be valuable for the evaluation of myocardial viability in clinical routine. PMID:15939722

  2. Usefulness of myocardial parametric imaging to evaluate myocardial viability in experimental and in clinical studies.

    PubMed

    Korosoglou, G; Hansen, A; Bekeredjian, R; Filusch, A; Hardt, S; Wolf, D; Schellberg, D; Katus, H A; Kuecherer, H

    2006-03-01

    To evaluate whether myocardial parametric imaging (MPI) is superior to visual assessment for the evaluation of myocardial viability. Myocardial contrast echocardiography (MCE) was assessed in 11 pigs before, during, and after left anterior descending coronary artery occlusion and in 32 patients with ischaemic heart disease by using intravenous SonoVue administration. In experimental studies perfusion defect area assessment by MPI was compared with visually guided perfusion defect planimetry. Histological assessment of necrotic tissue was the standard reference. In clinical studies viability was assessed on a segmental level by (1) visual analysis of myocardial opacification; (2) quantitative estimation of myocardial blood flow in regions of interest; and (3) MPI. Functional recovery between three and six months after revascularisation was the standard reference. In experimental studies, compared with visually guided perfusion defect planimetry, planimetric assessment of infarct size by MPI correlated more significantly with histology (r2 = 0.92 versus r2 = 0.56) and had a lower intraobserver variability (4% v 15%, p < 0.05). In clinical studies, MPI had higher specificity (66% v 43%, p < 0.05) than visual MCE and good accuracy (81%) for viability detection. It was less time consuming (3.4 (1.6) v 9.2 (2.4) minutes per image, p < 0.05) than quantitative blood flow estimation by regions of interest and increased the agreement between observers interpreting myocardial perfusion (kappa = 0.87 v kappa = 0.75, p < 0.05). MPI is useful for the evaluation of myocardial viability both in animals and in patients. It is less time consuming than quantification analysis by regions of interest and less observer dependent than visual analysis. Thus, strategies incorporating this technique may be valuable for the evaluation of myocardial viability in clinical routine.

  3. Microcapsules: Reverse Sonoporation and Long-lasting, Safe Contrast

    NASA Astrophysics Data System (ADS)

    Wrenn, Steven; Dicker, Stephen; Small, Eleanor; Maghnouj, Abdelouahid; Hahn, Stephan A.; Mleczko, Michał; Hensel, Karin; Schmitz, Georg

    We present a novel vehicle designed to serve the dual roles of enhanced ultrasound contrast and ultrasound-triggered drug delivery. The vehicle is comprised of a microcapsule that is filled with water in whose aqueous core a population of freely floating, phospholipid-coated microbubbles is suspended. At ultrasound intensities below the inertial cavitation threshold of the microbubbles, the microbubbles provide enhanced ultrasound contrast. The measured contrast is comparable in strength with SonoVue®. Encapsulation of microbubbles within microcapsules putatively eliminates - or at least significantly slows - dissolution of gas in the bulk aqueous medium, thereby avoiding disappearance of microbubbles that would otherwise occur due to pressure-induced gas diffusion across the surfactant monolayer coating the microbubble-water interface. Results suggest that our vehicle might provide longer lasting contrast in a clinical setting. We demonstrate that encapsulation of the microbubbles within microcapsules causes at least a doubling of the ultrasound intensity necessary to induce inertial cavitation. Moreover, no cell death was observed when cells were insonified in the presence of microbubble-containing microcapsules, whereas appreciable cell death occurs with unencapsulated microbubbles. These results point toward a potential safety benefit during ultrasound contrast imaging by using encapsulated microbubbles. Studies are underway to investigate the feasibility of ultrasound-triggered release of drug from the microcapsules, owing to inertial- or stable-cavitation, or both. Whereas leakage from polymeric microcapsule shells, such as poly(lactic acid), seemingly requires shell rupture and is exceedingly difficult to achieve, leakage across a lipid bilayer microcapsule shells appears feasible. Leakage across a bilayer shell has the additional benefit that the leakage mechanism can be tuned via phase behavior (liquid-ordered versus liquid-disordered) and cavitation

  4. Results of vardenafil mediated power Doppler ultrasound, contrast enhanced ultrasound and systematic random biopsies to detect prostate cancer.

    PubMed

    Morelli, Girolamo; Pagni, Riccardo; Mariani, Chiara; Minervini, Riccardo; Morelli, Andrea; Gori, Francesco; Ferdeghini, Ezio Maria; Paterni, Marco; Mauro, Eva; Guidi, Elisa; Armillotta, Nicola; Canale, Domenico; Vitti, Paolo; Caramella, Davide; Minervini, Andrea

    2011-06-01

    We evaluated the ability of the phosphodiesterase-5 inhibitor vardenafil to increase prostate microcirculation during power Doppler ultrasound. We also evaluated the results of contrast and vardenafil enhanced targeted biopsies compared to those of standard 12-core random biopsies to detect cancer. Between May 2008 and January 2010, 150 consecutive patients with prostate specific antigen more than 4 ng/ml at first diagnosis with negative digital rectal examination and transrectal ultrasound, and no clinical history of prostatitis underwent contrast enhanced power Doppler ultrasound (bolus injection of 2.4 ml SonoVue® contrast agent), followed by vardenafil enhanced power Doppler ultrasound (1 hour after oral administration of vardenafil 20 mg). All patients underwent standard 12-core transrectal ultrasound guided random prostate biopsy plus 1 further sampling from each suspected hypervascular lesion detected by contrast and vardenafil enhanced power Doppler ultrasound. Prostate cancer was detected in 44 patients (29.3%). Contrast and vardenafil enhanced power Doppler ultrasound detected suspicious, contrast enhanced and vardenafil enhanced areas in 112 (74.6%) and 110 patients (73.3%), and was diagnostic for cancer in 32 (28.5%) and 42 (38%), respectively. Analysis of standard technique, and contrast and vardenafil enhanced power Doppler ultrasound findings by biopsy core showed significantly higher detection using vardenafil vs contrast enhanced power Doppler ultrasound and standard technique (41.2% vs 22.7% and 8.1%, p <0.005 and <0.001, respectively). The detection rate of standard plus contrast or vardenafil enhanced power Doppler ultrasound was 10% and 11.7% (p not significant). Vardenafil enhanced power Doppler ultrasound enables excellent visualization of the microvasculature associated with cancer and can improve the detection rate compared to contrast enhanced power Doppler ultrasound and the random technique. Copyright © 2011 American Urological

  5. Color-coded perfusion analysis of CEUS for pre-interventional diagnosis of microvascularisation in cases of vascular malformations.

    PubMed

    Teusch, V I; Wohlgemuth, W A; Piehler, A P; Jung, E M

    2014-01-01

    Aim of our pilot study was the application of a contrast-enhanced color-coded ultrasound perfusion analysis in patients with vascular malformations to quantify microcirculatory alterations. 28 patients (16 female, 12 male, mean age 24.9 years) with high flow (n = 6) or slow-flow (n = 22) malformations were analyzed before intervention. An experienced examiner performed a color-coded Doppler sonography (CCDS) and a Power Doppler as well as a contrast-enhanced ultrasound after intravenous bolus injection of 1 - 2.4 ml of a second-generation ultrasound contrast medium (SonoVue®, Bracco, Milan). The contrast-enhanced examination was documented as a cine sequence over 60 s. The quantitative analysis based on color-coded contrast-enhanced ultrasound (CEUS) images included percentage peak enhancement (%peak), time to peak (TTP), area under the curve (AUC), and mean transit time (MTT). No side effects occurred after intravenous contrast injection. The mean %peak in arteriovenous malformations was almost twice as high as in slow-flow-malformations. The area under the curve was 4 times higher in arteriovenous malformations compared to the mean value of other malformations. The mean transit time was 1.4 times higher in high-flow-malformations compared to slow-flow-malformations. There was no difference regarding the time to peak between the different malformation types. The comparison between all vascular malformation and surrounding tissue showed statistically significant differences for all analyzed data (%peak, TTP, AUC, MTT; p < 0.01). High-flow and slow-flow vascular malformations had statistically significant differences in %peak (p < 0.01), AUC analysis (p < 0.01), and MTT (p < 0.05). Color-coded perfusion analysis of CEUS seems to be a promising technique for the dynamic assessment of microvasculature in vascular malformations.

  6. Transient permeabilization of cell membranes by ultrasound-exposed microbubbles is related to formation of hydrogen peroxide.

    PubMed

    Juffermans, L J M; Dijkmans, P A; Musters, R J P; Visser, C A; Kamp, O

    2006-10-01

    In the present study, we addressed the interactions among ultrasound, microbubbles, and living cells as well as consequent arising bioeffects. We specifically investigated whether hydrogen peroxide (H(2)O(2)) is involved in transient permeabilization of cell membranes in vitro after ultrasound exposure at low diagnostic power, in the presence of stable oscillating microbubbles, by measuring the generation of H(2)O(2) and Ca(2+) influx. Ultrasound, in the absence or presence of SonoVue microbubbles, was applied to H9c2 cells at 1.8 MHz with a mechanical index (MI) of 0.1 or 0.5 during 10 s. This was repeated every minute, for a total of five times. The production of H(2)O(2) was measured intracellularly with CM-H(2)DCFDA. Cell membrane permeability was assessed by measuring real-time changes in intracellular Ca(2+) concentration with fluo-4 using live-cell fluorescence microscopy. Ultrasound, in the presence of microbubbles, caused a significant increase in intracellular H(2)O(2) at MI 0.1 of 50% and MI 0.5 of 110% compared with control (P < 0.001). Furthermore, we found increases in intracellular Ca(2+) levels at both MI 0.1 and MI 0.5 in the presence of microbubbles, which was not detected in the absence of extracellular Ca(2+). In addition, in the presence of catalase, Ca(2+) influx immediately following ultrasound exposure was completely blocked at MI 0.1 (P < 0.01) and reduced by 50% at MI 0.5 (P < 0.001). Finally, cell viability was not significantly affected, not even 24 h later. These results implicate a role for H(2)O(2) in transient permeabilization of cell membranes induced by ultrasound-exposed microbubbles.

  7. STOP-Bang questionnaire: translation to Portuguese and cross-cultural adaptation for use in Brazil.

    PubMed

    Fonseca, Lorena Barbosa de Moraes; Silveira, Erika Aparecida; Lima, Nathalia Meireles; Rabahi, Marcelo Fouad

    2016-01-01

    falada no Brasil, de forma a possibilitar sua aplicação como instrumento de triagem para o diagnóstico da apneia obstrutiva do sono. Embasado nos princípios de boas práticas para a tradução e adaptação transcultural desses instrumentos, o protocolo incluiu os seguintes passos: obtenção de autorização da autora principal do questionário original; tradução, realizada por dois tradutores; reconciliação; tradução retrógrada realizada por dois professores de inglês procedentes de países de língua inglesa e fluentes na língua portuguesa; revisão da tradução retrógrada; harmonização; revisão e aprovação do questionário pela autora original; desdobramento cognitivo com 14 pacientes que responderam ao questionário; análise dos resultados; e revisão e preparação da versão final do instrumento pelo comitê revisor. A versão final do questionário STOP-Bang traduzida para a língua portuguesa falada no Brasil apresentou uma média de clareza > 9 (em uma escala de 1-10) em todas as questões. O coeficiente alfa de Cronbach foi de 0,62, demonstrando a consistência interna do instrumento. As médias e desvios-padrão da idade, do índice de massa corpórea e da circunferência de pescoço dos pacientes foram de, respectivamente, 46,8 ± 11,2 anos, 43,7 ± 8,5 kg/m² e 41,3 ± 3,6 cm. O questionário STOP-Bang mostrou-se compreensível, claro e aplicável. Houve consistência na equivalência do questionário original com o traduzido e adaptado para uso no Brasil, podendo esse se tornar um instrumento de triagem amplamente utilizado para pacientes com suspeita de apneia obstrutiva do sono.

  8. Stable cavitation using acoustic phase-change dodecafluoropentane nanoparticles for coronary micro-circulation thrombolysis.

    PubMed

    Hu, Bo; Jiang, Nan; Zhou, Qing; Cao, Sheng; Gao, Shunji; Zhang, Binghong; Chen, Jinling; Guo, Ruiqiang

    2018-06-11

    The thrombolysis in micro-circulation after acute myocardial infarction has been an unsolved issue, as elimination effect of acute thrombolysis and primary intervention were unsatisfied. Stable cavitation using acoustic phase-change nanoparticles may have potential for thrombolysis. Therefore, we sought to investigate a novel treatment method with dodecafluoropentane (DDFP) nanoparticles for rapid and effective thrombolysis in an in-vitro artificial vascular system, as a mimicking preparation of coronary circulation. To simulate thrombus embolism in coronary circulation, an in-vitro artificial vascular system was established with cavitation effect using DDFP nanoparticles. For PBS blank control (group A), SonoVue microbubbles (group B) and DDFP nanoparticles (group C), the durations for cavitation effect were recorded and the thrombolysis efficiency with low intensity focused ultrasound irradiation in the in-vitro vascular system were analyzed with weight loss and pathological changes of thrombus before and after thrombolysis. The optimal conditions for acoustic cavitation effect were power of 6 W for 20 min by ultrasound irradiation at 37 °C. The weight loss and weight loss rates of thrombus in group C (189.4 ± 30.2 mg and 34.2 ± 5.7%) were higher than those in group A (30.2 ± 16.0 mg and 5.2 ± 2.1%) and group B (84.0 ± 20.4 mg and 14.6 ± 1.5%) (P < 0.01, all). The duration for cavitation effect in group C (32.8 ± 3.9 min) was also longer than those in group A (0.0 ± 0.0 min) and group B (5.3 ± 0.3 min) (P < 0.01, all). By stable and sustaining cavitation in targeted area, DDFP nanoparticles with ultrasound irradiation have significantly increased the thrombolysis efficiency, which has provided a powerful experimental foundation for potential coronary thrombolysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Value of contrast-enhanced ultrasound in differential diagnosis of solid lesions of pancreas (SLP): A systematic review and a meta-analysis.

    PubMed

    Ran, Li; Zhao, Wenli; Zhao, Ye; Bu, Huaien

    2017-07-01

    Contrast-enhanced ultrasound (CEUS) is considered a novel method for diagnosing pancreatic cancer, but currently, there is no conclusive evidence of its accuracy. Using CEUS in discriminating between pancreatic carcinoma and other pancreatic lesions, we aimed to evaluate the diagnostic accuracy of CEUS in predicting pancreatic tumours. Relevant studies were selected from the PubMed, Cochrane Library, Elsevier, CNKI, VIP, and WANFANG databases dating from January 2006 to May 2017. The following terms were used as keywords: "pancreatic cancer" OR "pancreatic carcinoma," "contrast-enhanced ultrasonography" OR "contrast-enhanced ultrasound" OR "CEUS," and "diagnosis." The selection criteria are as follows: pancreatic carcinomas diagnosed by CEUS while the main reference standard was surgical pathology or biopsy (if it involved a clinical diagnosis, particular criteria emphasized); SonoVue or Levovist was the contrast agent; true positive, false positive, false negative, and true negative rates were obtained or calculated to construct the 2 × 2 contingency table; English or Chinese articles; at least 20 patients were enrolled in each group. The Quality Assessment for Studies of Diagnostic Accuracy was employed to evaluate the quality of articles. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, summary receiver-operating characteristic curves, and the area under curve were evaluated to estimate the overall diagnostic efficiency. Pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio with 95% confidence intervals (CIs) were calculated with fixed-effect models. Eight of 184 records were eligible for a meta-analysis after independent scrutinization by 2 reviewers. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratios were 0.86 (95% CI 0.81-0.90), 0.75 (95% CI 0.68-0.82), 3.56 (95% CI 2.64-4.78), 0.19 (95% CI 0

  10. Novel lactoferrin-conjugated amphiphilic poly(aminoethyl ethylene phosphate)/poly(L-lactide) copolymer nanobubbles for tumor-targeting ultrasonic imaging

    PubMed Central

    Luo, Binhua; Liang, Huageng; Zhang, Shengwei; Qin, Xiaojuan; Liu, Xuhan; Liu, Wei; Zeng, Fuqing; Wu, Yun; Yang, Xiangliang

    2015-01-01

    In the study reported here, a novel amphiphilic poly(aminoethyl ethylene phosphate)/poly(L-lactide) (PAEEP-PLLA) copolymer was synthesized by ring-opening polymerization reaction. The perfluoropentane-filled PAEEP-PLLA nanobubbles (NBs) were prepared using the O1/O2/W double-emulsion and solvent-evaporation method, with the copolymer as the shell and liquid perfluoropentane as the core of NBs. The prepared NBs were further conjugated with lactoferrin (Lf) for tumor-cell targeting. The resulting Lf-conjugated amphiphilic poly(aminoethyl ethylene phosphate)/poly(L-lactide) nanobubbles (Lf-PAEEP-PLLA NBs) were characterized by photon correlation spectroscopy, polyacrylamide gel electrophoresis, Fourier transform infrared spectroscopy, and transmission electron microscopy. The average size of the Lf-PAEEP-PLLA NBs was 328.4±5.1 nm, with polydispersity index of 0.167±0.020, and zeta potential of −12.6±0.3 mV. Transmission electron microscopy imaging showed that the Lf-PAEEP-PLLA NBs had a near-spherical structure, were quite monodisperse, and there was a clear interface between the copolymer shell and the liquid core inside the NBs. The Lf-PAEEP-PLLA NBs also exhibited good biocompatibility in cytotoxicity and hemolysis studies and good stability during storage. The high cellular uptake of Lf-PAEEP-PLLA NBs in C6 cells (low-density lipoprotein receptor-related protein 1-positive cells) at concentrations of 0–20 µg/mL indicated that the Lf provided effective targeting for brain-tumor cells. The in vitro acoustic behavior of Lf-PAEEP-PLLA NBs was evaluated using a B-mode clinical ultrasound imaging system. In vivo ultrasound imaging was performed on tumor-bearing BALB/c nude mice, and compared with SonoVue® microbubbles, a commercial ultrasonic contrast agent. Both in vitro and in vivo ultrasound imaging indicated that the Lf-PAEEP-PLLA NBs possessed strong, long-lasting, and tumor-enhanced ultrasonic contrast ability. Taken together, these results indicate that

  11. Novel lactoferrin-conjugated amphiphilic poly(aminoethyl ethylene phosphate)/poly(L-lactide) copolymer nanobubbles for tumor-targeting ultrasonic imaging.

    PubMed

    Luo, Binhua; Liang, Huageng; Zhang, Shengwei; Qin, Xiaojuan; Liu, Xuhan; Liu, Wei; Zeng, Fuqing; Wu, Yun; Yang, Xiangliang

    2015-01-01

    In the study reported here, a novel amphiphilic poly(aminoethyl ethylene phosphate)/poly(L-lactide) (PAEEP-PLLA) copolymer was synthesized by ring-opening polymerization reaction. The perfluoropentane-filled PAEEP-PLLA nanobubbles (NBs) were prepared using the O1/O2/W double-emulsion and solvent-evaporation method, with the copolymer as the shell and liquid perfluoropentane as the core of NBs. The prepared NBs were further conjugated with lactoferrin (Lf) for tumor-cell targeting. The resulting Lf-conjugated amphiphilic poly(aminoethyl ethylene phosphate)/poly(L-lactide) nanobubbles (Lf-PAEEP-PLLA NBs) were characterized by photon correlation spectroscopy, polyacrylamide gel electrophoresis, Fourier transform infrared spectroscopy, and transmission electron microscopy. The average size of the Lf-PAEEP-PLLA NBs was 328.4±5.1 nm, with polydispersity index of 0.167±0.020, and zeta potential of -12.6±0.3 mV. Transmission electron microscopy imaging showed that the Lf-PAEEP-PLLA NBs had a near-spherical structure, were quite monodisperse, and there was a clear interface between the copolymer shell and the liquid core inside the NBs. The Lf-PAEEP-PLLA NBs also exhibited good biocompatibility in cytotoxicity and hemolysis studies and good stability during storage. The high cellular uptake of Lf-PAEEP-PLLA NBs in C6 cells (low-density lipoprotein receptor-related protein 1-positive cells) at concentrations of 0-20 µg/mL indicated that the Lf provided effective targeting for brain-tumor cells. The in vitro acoustic behavior of Lf-PAEEP-PLLA NBs was evaluated using a B-mode clinical ultrasound imaging system. In vivo ultrasound imaging was performed on tumor-bearing BALB/c nude mice, and compared with SonoVue(®) microbubbles, a commercial ultrasonic contrast agent. Both in vitro and in vivo ultrasound imaging indicated that the Lf-PAEEP-PLLA NBs possessed strong, long-lasting, and tumor-enhanced ultrasonic contrast ability. Taken together, these results indicate that Lf

  12. Anti-metastatic and pro-apoptotic effects elicited by combination photodynamic therapy with sonodynamic therapy on breast cancer both in vitro and in vivo.

    PubMed

    Wang, Pan; Li, Caifeng; Wang, Xiaobing; Xiong, Wenli; Feng, Xiaolan; Liu, Quanhong; Leung, Albert Wingnang; Xu, Chuanshan

    2015-03-01

    Sono-Photodynamic therapy (SPDT), a new modality for cancer treatment, is aimed at enhancing anticancer effects by the combination of sonodynamic therapy (SDT) and photodynamic therapy (PDT). In this study, we investigated the antitumor effect and possible mechanisms of Chlorin e6 (Ce6) mediated SPDT (Ce6-SPDT) on breast cancer both in vitro and in vivo. MTT assay revealed that the combined therapy markedly enhanced cell viability loss of breast cancer cell lines (MDA-MB-231, MCF-7 and 4T1) compared with SDT and PDT alone. Propidium iodide/hoechst33342 double staining reflected that 4T1 cells with apoptotic morphological characteristics were significantly increased in groups given combined therapy. Besides, the combined therapy caused obvious mitochondrial membrane potential (MMP) loss at early 1 h post SPDT treatment. The generation of intracellular reactive oxygen species (ROS) detected by flow cytometry was greatly increased in 4T1 cells treated with the combination therapy, and the loss of cell viability and MMP could be effectively rescued by pre-treatment with the ROS scavenger N-acetylcysteine (NAC). Further, Ce6-SPDT markedly inhibited the tumor growth (volume and weight) and lung metastasis in 4T1 tumor-bearing mice, but had no effect on the body weight. Hematoxylin and eosin staining revealed obvious tissue destruction with large spaces in the Ce6-SPDT groups, and TUNEL staining indicated tumor cell apoptosis after treatment. Immunohistochemistry analysis showed that the expression level of VEGF and MMP were significantly decreased in the combined groups. These results indicated that Ce6-mediated SPDT enhanced the antitumor efficacy on 4T1 cells compared with SDT and PDT alone, loss of MMP and generation of ROS might be involved. In addition, Ce6-mediated SPDT significantly inhibited tumor growth and metastasis in mouse breast cancer 4T1 xenograft model, in which MMP-9 and VEGF may play a crucial role.

  13. Contrast-enhanced transrectal ultrasound (CE-TRUS) with cadence-contrast pulse sequence (CPS) technology for the identification of prostate cancer.

    PubMed

    Seitz, Michael; Gratzke, Christian; Schlenker, Boris; Buchner, Alexander; Karl, Alexander; Roosen, Alexander; Singer, Bernhard B; Bastian, Patrick J; Ergün, Süleyman; Stief, Christian G; Reich, Oliver; Tilki, Derya

    2011-01-01

    Various imaging modalities, such as magnetic resonance imaging (MRI), have been assessed with regard to their value in the detection of prostate cancer (CaP). However, there is a need for less time-consuming and more cost effective procedures in urology. In order to determine the ability of contrast-enhanced transrectal ultrasound (CE-TRUS) to identify CaP, we investigated patients scheduled for radical prostatectomy for CaP and radical cystoprostatectomy for bladder cancer. Between May and August 2008, 35 consecutive patients with CaP and muscle-invasive bladder carcinoma were prospectively enrolled in this single center study. All patients underwent B-mode TRUS and CE-TRUS (Sequoia 512 unit with an endocavity probe EV8C4, 8 MHz; Siemens, Erlangen, Germany) by one investigator blinded to any clinical data before radical surgery. Contrast-enhanced images were obtained after intravenous infusion of a bolus (2.4 ml) of the contrast agent SonoVue (Bracco, Milan, Italy). Ultrasound findings (CE-TRUS and B-mode TRUS) were correlated with step-section histology. On a per-patient basis, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for detecting CaP with CE-TRUS were 71.0%, 50.0%, 91.7%, and 18.2%, respectively. In comparison with B-mode TRUS (sensitivity 45.2%, specificity 75.0%, PPV 93.3%, and NPV 18.0%), CE-TRUS performed significantly better (P=0.004, McNemar test). On a per-prostate-lobe basis sensitivity, specificity, PPV, and NPV were 69.0%, 33.3%, 83.3%, and 18.2%. CE-TRUS detected prostate cancer with a modest sensitivity and a high PPV in a selected patient cohort. Future randomized-controlled multicenter studies are needed to further validate the value of CE-TRUS in the detection of CaP. Based on our results, CE-TRUS may not be recommended as a routine procedure in the diagnosis of CaP at present. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. Comparative sonographic evaluation of the anteroposterior dimensions of the pancreas in diabetics and nondiabetics.

    PubMed

    Agabi, J O; Akhigbe, A O

    2016-01-01

    The pancreas is an insulin-producing gland and is prone to varying degrees of destruction and change in patients with diabetes mellitus (DM). Various morphological changes including reduction in the pancreas dimensions have been described in DM. To determine pancreatic anteroposterior (AP) dimensions in diabetics by sonography and compare with nondiabetics. To also evaluate the correlation of the AP dimensions with patient's anthropometry, as well as the duration of the disease in comparison with nondiabetics. This is a comparative cross-sectional study involving 150 diabetics with 150 sex and age matched healthy normoglycemic group used as controls. Sonographic measurements of the AP dimensions of the pancreatic head, body, and tail of both study groups were performed with the use of 3.5 MHz curvilinear array transducer of a SonoAce X4 ultrasound machine. Data were analyzed using Statistical Package for Social Sciences version 17 (SPSS Inc., Chicago, IL, USA). A statistical test was considered significant at P ≤ 0.05 and 95% confidence interval. Pancreas AP dimensions were significantly smaller in diabetics compared to those of the controls. The mean dimensions were 1.91 ± 0.26 cm, 0.95 ± 0.12 cm, and 0.91 ± 0.11 cm for the head, body, and tail, respectively, in diabetics and 2.32 ± 0.22 cm, 1.43 ± 0.19 cm, and 1.34 ± 0.20 cm in the control (P < 0.001 in all cases). The dimensions were also significantly smaller in the Type 1 diabetics compared to Type 2 (P < 0.001 in all cases). The mean duration of illness for the Types 1 and 2 diabetics were 3.09 ± 1.38 and 3.78 ± 3.12 years, respectively. Longer duration of illness was associated with smaller pancreas body and tail dimensions, while pancreas head dimension was not significantly affected by the duration of illness. Diabetics have smaller pancreas AP dimensions compared to the normal population.

  15. The effect of repeated altitude exposures on the incidence of decompression sickness

    NASA Technical Reports Server (NTRS)

    Pilmanis, Andrew A.; Webb, James T.; Kannan, Nandini; Balldin, Ulf

    2002-01-01

    INTRODUCTION: Repeated altitude exposures in a single day occur during special operations parachute training, hypobaric chamber training, unpressurized flight, and extravehicular space activity. Inconsistent and contradictory information exists regarding the risk of decompression sickness (DCS) during such hypobaric exposures. HYPOTHESIS: We hypothesized that four short exposures to altitude with and without ground intervals would result in a lower incidence of DCS than a single exposure of equal duration. METHODS: The 32 subjects were exposed to 3 different hypobaric exposures--condition A: 2 h continuous exposure (control); condition B: four 30-min exposures with descent/ascent but no ground interval between the exposures; condition C: four 30-min exposures with descent/ascent and 60 min of ground interval breathing air between exposures. All exposures were to 25,000 ft with 100% oxygen breathing. Subjects were observed for symptoms of DCS, and precordial monitoring of venous gas emboli (VGE) was accomplished with a SONOS 1000 echo-imaging system. RESULTS: DCS occurred in 19 subjects during A (mean onset 70+/-29 min), 7 subjects in B (60+/-34 min), and 2 subjects in C (40+/-18 min). There was a significant difference in DCS incidence between B and A (p = 0.0015) and C and A (p = 0.0002), but no significant difference between B and C. There were 28 cases of VGE in A (mean onset 30+/-23 min), 21 in B (41+/-35 min), and 21 in C (41+/-32 min) with a significant onset curve difference between B and A and between C and A, but not between B and C. Exposure A resulted in four cases of serious respiratory/neurological symptoms, while B had one and C had none. All symptoms resolved during recompression to ground level. CONCLUSION: Data indicate that repeated simulated altitude exposures to 25,000 ft significantly reduce DCS and VGE incidence compared with a single continuous altitude exposure.

  16. Development of Next Generation Memory Test Experiment for Deployment on a Small Satellite

    NASA Technical Reports Server (NTRS)

    MacLeod, Todd; Ho, Fat D.

    2012-01-01

    The original Memory Test Experiment successfully flew on the FASTSAT satellite launched in November 2010. It contained a single Ramtron 512K ferroelectric memory. The memory device went through many thousands of read/write cycles and recorded any errors that were encountered. The original mission length was schedule to last 6 months but was extended to 18 months. New opportunities exist to launch a similar satellite and considerations for a new memory test experiment should be examined. The original experiment had to be designed and integrated in less than two months, so the experiment was a simple design using readily available parts. The follow-on experiment needs to be more sophisticated and encompass more technologies. This paper lays out the considerations for the design and development of this follow-on flight memory experiment. It also details the results from the original Memory Test Experiment that flew on board FASTSAT. Some of the design considerations for the new experiment include the number and type of memory devices to be used, the kinds of tests that will be performed, other data needed to analyze the results, and best use of limited resources on a small satellite. The memory technologies that are considered are FRAM, FLASH, SONOS, Resistive Memory, Phase Change Memory, Nano-wire Memory, Magneto-resistive Memory, Standard DRAM, and Standard SRAM. The kinds of tests that could be performed are read/write operations, non-volatile memory retention, write cycle endurance, power measurements, and testing Error Detection and Correction schemes. Other data that may help analyze the results are GPS location of recorded errors, time stamp of all data recorded, radiation measurements, temperature, and other activities being perform by the satellite. The resources of power, volume, mass, temperature, processing power, and telemetry bandwidth are extremely limited on a small satellite. Design considerations must be made to allow the experiment to not interfere

  17. Parametric imaging of clear cell and papillary renal cell carcinoma using contrast-enhanced ultrasound (CEUS).

    PubMed

    Rübenthaler, J; Reimann, R; Hristova, P; Staehler, M; Reiser, M; Clevert, D A

    2015-10-16

    The aim of this study was to analyse clear cell and papillary renal cell carcinoma (RCC) examined with contrast-enhanced ultrasound (CEUS) and a second generation blood pool agent (SonoVue®, Bracco, Milan, Italy) before clinical intervention. A total of 41 patients with histologically proven subtypes of RCC were examined. 29 patients had a clear cell RCC and 12 patients showed a papillary RCC. Average size in the clear cell RCC group was 6.07 cm and 1.88 cm in the papillary RCC group. An experienced radiologist examined all patients with CEUS. The following parameters were analysed: maximum signal intensity (PEAK), time elapsed until PEAK is reached (MTT), local blood flow (RBF), area under the time intensity curve (AUC) and the signal intensity (SI) during the course of time. For both groups all comparisons were made based on healthy renal parenchyma. In the clear cell RCC significant differences (significance level p < 0.05) between cancerous tissue and the healthy renal parenchyma were noticed in all four parameters. The clear cell RCC showed a significant reduced blood volume. It reached the PEAK reading relatively rapidly and its signal intensity was always lower than that of the healthy renal parenchyma. In the arterial phase retarded absorption of the contrast agent was observed, followed by fast washing out of the contrast agent bubbles.In the papillary RCC group, significant findings as to PEAK and RBF as well as a slightly significant difference as to AUC were recorded. The papillary RCC had a lower blood supply and reached its PEAK reading later. Its signal intensity was also reduced. The signal intensity of papillary NCC was significantly lower compared with clear cell RCC; absorption and washing out of the contrast agent was delayed. CEUS seems to be an useful additional method to clinically differentiate between clear cell and papillary RCC. In daily clinical use, patients with contraindication for other imaging methods, especially the

  18. Characterization of histological subtypes of clear cell renal cell carcinoma using contrast-enhanced ultrasound (CEUS).

    PubMed

    Reimann, R; Rübenthaler, J; Hristova, P; Staehler, M; Reiser, M; Clevert, D A

    2015-10-16

    The aim of this study was to analyze the histological subtypes of clear cell renal cell carcinoma (RCC) examined by means of contrast-enhanced ultrasound (CEUS) and a second generation blood pool agent (SonoVue®, Bracco, Milan, Italy) during the pre-operative phase. 29 patients with histologically proven subtypes of clear cell RCC were examined. A total of three patients were diagnosed with highly differentiated clear cell RCC, 21 out of 29 cases with moderately differentiated clear cell RCC and five out of 29 patients had insufficiently differentiated clear cell RCC. An experienced radiologist examined the patients with CEUS. The following parameters were analyzed: maximum signal intensity (PEAK), time elapsed until PEAK is reached (MTT), local blood flow (RBF), area under the time intensity curve (AUC) and the signal intensity (SI) during the course of time. For the groups all comparisons are made based on healthy renal parenchyma. In the clear cell RCC significant differences (significance level p < 0.05) between cancerous tissue and the healthy renal parenchyma were noticed in all four parameters. Therefore, the clear cell RCC stands out due to its reduced blood volume. However, it reached the PEAK reading relatively rapidly and its signal intensity was always lower than that of the healthy renal parenchyma. In the arterial phase retarded absorption of the contrast agent was observed, followed by fast washing out of the contrast agent bubbles.In all three histological subgroups no significant differences were noticed in PEAK and SI. However, the diagrams showed the possible bias, that the group of the insufficiently differentiated clear cell RCC had the highest PEAK-value and the highest signal intensity when compared with highly and moderately differentiated clear cell RCC. Our study suggests that CEUS may be an additional tool for non-invasive characterisation and differentiation of the three histological subtypes of clear cell RCC. Furthermore, it seems

  19. [Comparative volumetry of human testes using special types of testicular sonography, Prader's orchidometer, Schirren's circle and sliding caliber].

    PubMed

    Dörnberger, V; Dörnberger, G

    1987-01-01

    On 99 testes of corpses (death had occurred between 26 und 86 years) comparative volumetry was done. In the left surrounding capsules (without scrotal skin and tunica dartos) the testes were measured via real time sonography in a waterbath (7.5 MHz linear-scan), afterwards length, breadth and height were measured by a sliding calibre, the largest diameter (the length) of the testis was determined by Schirren's circle and finally the size of the testis was measured via Prader's orchidometer. After all the testes were surgically exposed, their volume (by litres) was determined according to Archimedes' principle. As for the Archimedes' principle a random mean error of 7% must be accepted, sonographic determination of the volume showed a random mean error of 15%. Whereas the accuracy of measurement increases with increasing volumes, both methods should be used with caution if the volumes are below 4 ml, since the possibilities of error are rather great. According to Prader's orchidometer the measured volumes on average were higher (+ 27%) with a random mean error of 19.5%. With Schirren's circle the obtained mean value was even higher (+ 52%) in comparison to the "real" volume by Archimedes' principle with a random mean error of 19%. The measurements of the testes in the left capsules by sliding calibre can be optimized, if one applies a correcting factor f (sliding calibre) = 0.39 for calculation of the testis volume corresponding to an ellipsoid. Here you will get the same mean value as in Archimedes' principle with a standard mean error of only 9%. If one applies the correction factor of real time sonography of testis f (sono) = 0.65 the mean value of sliding calibre measurements would be 68.8% too high with a standard mean error of 20.3%. For measurements via sliding calibre the calculation of the testis volume corresponding to an ellipsoid one should apply the smaller factor f (sliding calibre) = 0.39, because in this way the left capsules of testis and the

  20. Image fusion of contrast enhanced ultrasound (CEUS) with computed tomography (CT) or magnetic resonance imaging (MRI) using volume navigation for detection, characterization and planning of therapeutic interventions of liver tumors.

    PubMed

    Rennert, J; Georgieva, M; Schreyer, A G; Jung, W; Ross, C; Stroszczynski, C; Jung, E M

    2011-01-01

    To evaluate, whether image fusion of contrast enhanced ultrasound (CEUS) with CT or MRI affects the diagnosis and characterization of liver lesions or the therapeutic strategy of surgical or interventional procedures compared to the preliminary diagnosis. In a retrospective study the image fusion scans of CEUS with contrast enhanced CT or MRI of 100 patients (71 male, mean age 59 years, 0.3-85 years) with benign or malignant liver lesions were evaluated. Fundamental B-scan, color Doppler imaging and CEUS were performed in all patients by an experienced examiner using a multifrequency convex transducer (1-5 MHz, LOGIQ 9/GE) and volume navigation (Vnav). After a bolus injections of up to 2.4 ml SonoVue® (BRACCO, Italy) digital raw data was stored as cine-loops up to 5 min. In 74 patients, CEUS was fused with a pre-existing ceCT, in 26 patients a ceMRI was used. In all 100 patients (100%) the image quality in all modalities (ceCT, ceMRI and CEUS) was excellent or with only minor diagnostic limitations. Regarding the number of lesions revealed in image fusion of CEUS/ceCT/ceMRI and the preceding diagnostic method, concordant results were found in 84 patients. In 12 patients, additional lesions were found using fusion imaging causing subsequently a change of the therapeutical strategy. In 15 out of 21 patients with either concordant or discordant results regarding the number of lesions, image fusion allowed a definite diagnosis due to a continuous documentation of the microcirculation of the tumor and its contrast enhancement. A significant coherency (p < 0.05) among image fusion with either ceCT or ceMRI and CEUS and a subsequent change of therapeutic strategy was found. Image fusion with volume navigation (VNav) of CEUS with ceCT or ceMRI frequently allows a definite localization and diagnosis of hepatic lesions in patients with primary hepatic carcinoma or metastatic diseases. This might cause a change of the therapeutic strategy in many patients with hepatic

  1. Combined steam-ultrasound treatment of 2 seconds achieves significant high aerobic count and Enterobacteriaceae reduction on naturally contaminated food boxes, crates, conveyor belts, and meat knives.

    PubMed

    Musavian, Hanieh S; Butt, Tariq M; Larsen, Annette Baltzer; Krebs, Niels

    2015-02-01

    Food contact surfaces require rigorous sanitation procedures for decontamination, although these methods very often fail to efficiently clean and disinfect surfaces that are visibly contaminated with food residues and possible biofilms. In this study, the results of a short treatment (1 to 2 s) of combined steam (95°C) and ultrasound (SonoSteam) of industrial fish and meat transportation boxes and live-chicken transportation crates naturally contaminated with food and fecal residues were investigated. Aerobic counts of 5.0 to 6.0 log CFU/24 cm(2) and an Enterobacteriaceae spp. level of 2.0 CFU/24 cm(2) were found on the surfaces prior to the treatment. After 1 s of treatment, the aerobic counts were significantly (P < 0.0001) reduced, and within 2 s, reductions below the detection limit (<10 CFU) were reached. Enterobacteriaceae spp. were reduced to a level below the detection limit with only 1 s of treatment. Two seconds of steam-ultrasound treatment was also applied on two different types of plastic modular conveyor belts with hinge pins and one type of flat flexible rubber belt, all visibly contaminated with food residues. The aerobic counts of 3.0 to 5.0 CFU/50 cm(2) were significantly (P < 0.05) reduced, while Enterobacteriaceae spp. were reduced to a level below the detection limit. Industrial meat knives were contaminated with aerobic counts of 6.0 log CFU/5 cm(2) on the handle and 5.2 log CFU/14 cm(2) on the steel. The level of Enterobacteriaceae spp. contamination was approximately 2.5 log CFU on the handle and steel. Two seconds of steam-ultrasound treatment reduced the aerobic counts and Enterobacteriaceae spp. to levels below the detection limit on both handle and steel. This study shows that the steam-ultrasound treatment may be an effective replacement for disinfection processes and that it can be used for continuous disinfection at fast process lines. However, the treatment may not be able to replace efficient cleaning processes used to remove high

  2. Clinical utility of three-dimensional contrast-enhanced ultrasound in the differentiation between noninvasive and invasive neoplasms of urinary bladder.

    PubMed

    Li, Qiu-yang; Tang, Jie; He, En-hui; Li, Yan-mi; Zhou, Yun; Zhang, Xu; Chen, Guangfu

    2012-11-01

    The purpose of this study was to evaluate the effectiveness of three-dimensional contrast-enhanced ultrasound in differentiating invasive and noninvasive neoplasms of urinary bladder. A total of 60 lesions in 60 consecutive patients with bladder tumors received three dimensional ultrasonography, low acoustic power contrast enhanced ultrasonography and low acoustic power three-dimensional contrast-enhanced ultrasound examination. The IU22 ultrasound scanner and a volume transducer were used and the ultrasound contrast agent was SonoVue. The contrast-specific sonographic imaging modes were PI (pulse inversion) and PM (power modulation). The three dimensional ultrasonography, contrast enhanced ultrasonography, and three-dimensional contrast-enhanced ultrasound images were independently reviewed by two readers who were not in the images acquisition. Images were analyzed off-site. A level of confidence in the diagnosis of tumor invasion of the muscle layer was assigned on a 5° scale. Receiver operating characteristic analysis was used to assess overall confidence in the diagnosis of muscle invasion by tumor. Kappa values were used to assess inter-readers agreement. Histologic diagnosis was obtained for all patients. Final pathologic staging revealed 44 noninvasive tumors and 16 invasive tumors. Three-dimensional contrast-enhanced ultrasound depicted all 16 muscle-invasive tumors. The diagnostic performance of three-dimensional contrast-enhanced ultrasound was better than those of three dimensional ultrasonography and contrast enhanced ultrasonography. The receiver operating characteristic curves were 0.976 and 0.967 for three-dimensional contrast-enhanced ultrasound, those for three dimensional ultrasonography were 0.881 and 0.869, those for contrast enhanced ultrasonography were 0.927 and 0.929. The kappa values in the three dimensional ultrasonography, contrast enhanced ultrasonography and three-dimensional contrast-enhanced ultrasound for inter-reader agreements

  3. Contrast-enhanced power Doppler endosonography and pathological assessment of vascularization in advanced gastric carcinomas--a feasibility study.

    PubMed

    Iordache, Sevastiţa; Filip, Maria-Monalisa; Georgescu, Claudia-Valentina; Angelescu, Cristina; Ciurea, Tudorel; Săftoiu, Adrian

    2012-06-01

    Besides representing angiogenesis markers, microvascular density (MVD) and vascular endothelial growth factor (VEGF) are two important tools for the assessment of prognosis in patients with gastric cancer. The aim of our study was to assess the Doppler parameters (resistivity and pulsatility indexes) and vascularity index (VI) calculated by contrast-enhanced power Doppler endoscopic ultrasound (CEPD-EUS) in correlation with the expression of intra-tumoral MVD and VEGF in patients with gastric cancer. The study included 20 consecutive patients with advanced gastric carcinoma, but without distant metastasis at initial assessment. All the patients were assessed by contrast-enhanced power Doppler endoscopic ultrasound (EUS) combined with pulsed Doppler examinations in the late venous phase. The vascularity index (VI) was calculated before and after injection of second generation microbubble contrast specific agent (SonoVue 2.4 mL), used as a Doppler signal enhancer. Moreover, pulsed Doppler parameters (resistivity and pulsatility indexes) were further calculated. The correlation between power Doppler parameters and pathological/molecular parameters (MVD assessed through immunohistochemistry with CD31 and CD34, as well as VEGF assessed through real-time PCR) was assessed. Kaplan-Meier survival analysis was used for the assessment of prognosis. Significantly statistical correlations were found between post-contrast VI and CD34 (p=0.0226), VEGF (p=0.0231), VEGF-A (p=0.0464) and VEGF-B (p=0.0022) while pre-contrast VI was correlated only with CD34 expression. Pulsatility index and resistivity index were not correlated with MVD or VEGF expression. Survival analysis demonstrated that VEGF-A is an accurate parameter for survival rate (p=0.045), as compared to VEGF (p=0.085) and VEGF-B (p=0.230). We did not find any correlation between the survival rate and ultrasound parameters (RI, PI, pre-contrast VI or post-contrast VI). Assessment of tumor vascularity using contrast

  4. Experimental characterization and modeling for the growth rate of oxide coatings from liquid solutions of metalorganic precursors by ultrasonic pulsed injection in a cold-wall low-pressure reactor

    NASA Astrophysics Data System (ADS)

    Krumdieck, Susan Pran

    Several years ago, a method for depositing ceramic coatings called the Pulsed-MOCVD system was developed by the Raj group at Cornell University in association with Dr. Harvey Berger and Sono-Tek Corporation. The process was used to produce epitaxial thin films of TiO2 on sapphire substrates under conditions of low pressure, relatively high temperature, and very low growth rate. The system came to CU-Boulder when Professor Raj moved here in 1997. It is quite a simple technique and has several advantages over typical CVD systems. The purpose of this dissertation is two-fold; (1) understand the chemical processes, thermodynamics, and kinetics of the Pulsed-MOCVD technique, and (2) determine the possible applications by studying the film structure and morphology over the entire range of deposition conditions. Polycrystalline coatings of ceramic materials were deposited on nickel in the low-pressure, cold-wall reactor from metalorganic precursors, titanium isopropoxide, and a mixture of zirconium isopropoxide and yttria isopropoxide. The process utilized pulsed liquid injection of a dilute precursor solution with atomization by ultrasonic nozzle. Thin films (less than 1mum) with fine-grained microstructure and thick coatings (up to 1mum) with columnar-microstructure were deposited on heated metal substrates by thermal decomposition of a single liquid precursor. The influence of each of the primary deposition parameters, substrate temperature, total flow rate, and precursor concentration on growth rate, conversion efficiency and morphology were investigated. The operating conditions were determined for kinetic, mass transfer, and evaporation process control regimes. Kinetic controlled deposition was found to produce equiaxed morphology while mass transfer controlled deposition produced columnar morphology. A kinetic model of the deposition process was developed and compared to data for deposition of TiO2 from Ti(OC3H7) 4 precursor. The results demonstrate that growth

  5. Opening of the blood-brain barrier with an unfocused ultrasound device in rabbits.

    PubMed

    Beccaria, Kevin; Canney, Michael; Goldwirt, Lauriane; Fernandez, Christine; Adam, Clovis; Piquet, Julie; Autret, Gwennhael; Clément, Olivier; Lafon, Cyril; Chapelon, Jean-Yves; Carpentier, Alexandre

    2013-10-01

    The blood-brain barrier (BBB) is a major impediment to the intracerebral diffusion of drugs used in the treatment of gliomas. Previous studies have demonstrated that pulsed focused ultrasound (US) in conjunction with a microbubble contrast agent can be used to open the BBB. To apply the US-induced opening of the BBB in clinical practice, the authors designed an innovative unfocused US device that can be implanted in the skull and used to transiently and repeatedly open the BBB during a standard chemotherapy protocol. The goal of this preliminary work was to study the opening of the BBB induced by the authors' small unfocused US transducer and to evaluate the effects of the sonications on brain parenchyma. Craniectomy was performed in 16 healthy New Zealand White rabbits; epidural application of a single-element planar ultrasonic transducer operating at 1 MHz was then used with a pulse-repetition frequency of 1 Hz, pulse lengths of 10-35 msec, in situ acoustic pressure levels of 0.3-0.8 MPa, and sonication for 60-120 seconds. SonoVue was intravenously injected during the US applications, and opening of the BBB was determined by detecting extravasation of Evans blue dye (EBD) in brain tissues, quantitative measurement of EBD with UV-visible spectrophotometry, and contrast enhancement after Gd injection in 4.7-T MRI. A histological study was performed to determine adverse effects. An opening of the BBB was observed over a large extent of the US beam in the brain corresponding to in situ pressures of greater than 0.2 MPa. The BBB opening observed was highly significant for both EBD (p < 0.01) and MRI Gd enhancement (p < 0.0001). The BBB opening was associated with minor adverse effects that included perivascular red blood cell extravasations that were less than 150 μm in size and not visible on MR images. Moderate edema was visible on FLAIR sequences and limited to the extent of the sonication field. The results demonstrate that the BBB can be opened in large areas of

  6. The dynamic of FUS-induced BBB Opening in Mouse Brain assessed by contrast enhanced MRI

    NASA Astrophysics Data System (ADS)

    Jenne, Jürgen W.; Krafft, Axel J.; Maier, Florian; Krause, Marie N.; Kleber, Susanne; Huber, Peter E.; Martin-Villalba, Ana; Bock, Michael

    2010-03-01

    Focused ultrasound (FUS) in combination with the administration of gas-filled microbubbles, can induce a localized and reversible opening of the blood brain barrier (BBB). Contrast enhanced magnetic resonance imaging (MRI) has been demonstrated as a precise tool to monitor such a local BBB disruption. However, the opening/closing mechanisms of the BBB with FUS are still largely unknown. In this ongoing project, we study the BBB opening dynamics in mouse brain comparing an interstitial and an intravascular MR contrast agent (CA). FUS in mouse brain was performed with an MRI compatible treatment setup (1.7 MHz fix-focus US transducer, f' = 68 mm, NA = 0.44; focus: 8.1 mm length; O/ = 1.1 mm) in a 1.5 T whole body MRI system. For BBB opening, forty 10 ms-long FUS-pulses were applied at a repetition rate of 1 Hz at 1 MPa. The i.v. administration of the micro bubbles (50 μl SonoVue®) was started simultaneously with FUS exposure. To analyze the BBB opening process, short-term and long-term MRI signal dynamics of the interstitial MR contrast agent Magnevist® and the intravascular CA Vasovist® (Bayer-Schering) were studied. To assess short-term signal dynamics, T1-weighted inversion recovery turbo FLASH images (1s) were repeatedly acquired. Repeated 3D FLASH acquisitions (90 s) were used to assess long-term MRI signal dynamics. The short-term MRI signal enhancements showed comparable time constants for both types of MR contrast agents: 1.1 s (interstitial) vs. 0.8 s (intravascular). This time constant may serve as a time constant of the BBB opening process with the given FUS exposure parameters. For the long-term signal dynamics the intravascular CA (62±10 min) showed a fife times greater time constant as the interstitial contrast agent (12±10 min). This might be explained by the high molecular weight (˜60 kDa) of the intravascular Vasovist due to its reversible binding to blood serum albumin resulting in a prolonged half-life in the blood stream compared to the

  7. What proportions of focal liver lesions detected by unenhanced ultrasound are inconclusive?

    PubMed Central

    Willits, Iain; Burn, Julie; Cole, Helen; Hoare, Tim

    2014-01-01

    In August 2012, the National Institute for Health and Care Excellence produced positive diagnostics guidance on the ultrasound contrast agent SonoVue®, but recommended further research involving an estimation of the proportion of unenhanced ultrasound scans reporting, but not characterising, focal liver lesions, particularly in cirrhotic livers. Patient records from the Radiology Information System of an acute hospital trust were progressively filtered based on categorical fields and keywords in the free text reports, to obtain ultrasound records including the liver that were appropriate for manual analysis. In total, 21,731 records referred from general practice or out-patient clinics were analysed. Patients described as having cirrhosis were analysed as a subgroup. After automatic exclusion of records considered likely to be negative, 5812 records were manually read and categorised as focal liver lesion inconclusive, benign or malignant. In the general practice cohort of 9175 records, 746 reported the presence of one or more focal liver lesions, with 18.4% (95% CI 15.7% to 21.3%) of these records mentioning an inconclusive focal liver lesion. In the out-patient cohort of 12,556 records, 1437 reported one or more focal liver lesions, and 29.4% (95% CI 26.9% to 32.0%) of these were inconclusive. Cirrhosis was reported in 10.8% of the out-patient scans that also reported a focal liver lesion, and 47.4% (95% CI 39.3% to 55.6%) of these scans had an inconclusive focal liver lesion, compared with 27.3% (95% CI 24.9% to 29.8%) that were inconclusive in non-cirrhotic livers (odds ratio 2.4; 95% CI 1.7 to 3.4). This retrospective study indicates that unenhanced ultrasound scans, in which a focal liver lesion is detected, are frequently inconclusive, with the probability of an inconclusive scan being greater in out-patient than general practice referrals. Inconclusive focal liver lesions were also reported in greater proportions of cirrhotic than non-cirrhotic livers. The

  8. Serum pentosidine concentration is associated with radiographic severity of lumbar spondylosis in a general Japanese population.

    PubMed

    Chiba, Daisuke; Wada, Kanichiro; Tanaka, Toshihiro; Kumagai, Gentaro; Sasaki, Eiji; Takahashi, Ippei; Nakaji, Shigeyuki; Ishibashi, Yasuyuki

    2017-01-01

    The aim of this study was to investigate the relationship between the radiographic severity of lumbar spondylosis (LS) and serum bone metabolic markers. A total of 681 individuals volunteered for this study (269 men, 412 women; age: 54.9 ± 14.3; body mass index [BMI]: 23.1 ± 3.3 kg/m 2 ). Lateral lumbar radiographs were evaluated in each intervertebral section (L1/2 to L5/S1) using the Kellgren-Lawrence grade (KL). If at least one intervertebral section was graded as KL 2 or greater, the participants were considered to have LS. The summation of each section of intervertebral section was used as the radiographic severity value of LS. In addition, bone status was evaluated with an osteo-sono assessment index (OSI) at the calcaneus. Serum bone alkaline phosphatase (μg/mL), N-telopeptide of type I collagen (nMBCE/L), and pentosidine (pmol/mL) concentrations were examined and used as the bone metabolism index. Stepwise multiple linear regression analysis was conducted with the radiographic severity value of LS as the dependent variable and age, sex, BMI, OSI, and the value of serum bone metabolic markers as the independent variables. The total number of LS participants was 470 (69.0 %); the frequency of LS was higher in men (n = 198) than in women (n = 272; P = 0.036, χ 2 test). The mean severity value of LS was 7.1 ± 4.4, and the mean value of pentosidine was 120.7 ± 54.8 pmol/mL. On multiple regression analysis, age (B = 0.190, β = 0.611), sex (men = 1, women = 2; B = -0.900, β = -0.099), BMI (B = 0.185, β = 0.136), and pentosidine (B = 0.009, β = 0.115) were significantly correlated with the severity of LS. Serum pentosidine concentration was positively correlated with the radiographic severity of LS in this cross-sectional study.

  9. [Contrast-enhanced Ultrasound in Diagnostic Imaging of Muscle Injuries: Perfusion Imaging in the Early Arterial Phase].

    PubMed

    Hotfiel, T; Carl, H D; Swoboda, B; Engelhardt, M; Heinrich, M; Strobel, D; Wildner, D

    2016-03-01

    Ultrasound is a standard procedure widely used in the diagnostic investigation of muscle injuries and widely described in the literature. Its advantages include rapid availability, cost effectiveness and the possibility to perform a real-time dynamic examination with the highest possible spatial resolution. In the diagnostic work-up of minor lesions (muscle stiffness, muscle strain), plain ultrasound has so far been inferior to MRI. The case presented by us is an example of the possibilities offered by contrast-enhanced ultrasound (CEUS) in the imaging of muscle injuries compared with plain B-mode image ultrasound and MRI imaging of the affected region. This case report is about a high-performance football player who sustained a muscle injury. He underwent an ultrasound examination (S 2000, 9L4 Probe, Siemens, Germany), which was performed simultaneously in the conventional and contrast-enhanced mode at the level of the lesion. An intravenous bolus injection of 4.8 ml of intravascular contrast agent (SonoVue(®), Bracco, Italy) was given via a cubital intravenous line. After that, the distribution of contrast agent was visualised in the early arterial phase. In addition, a plain magnetic resonance imaging scan of both thighs was performed for reference. On conventional ultrasound, the lesion was not clearly distinguishable from neighbouring tissue, whereas contrast-enhanced ultrasound demonstrated a well delineated, circumscribed area of impaired perfusion with hypoenhancement compared with the surrounding muscles at the clinical level of the lesion in the arterial wash-in phase (0-30 sec, after intravenous administration). The MRI scan revealed an edema signal with perifascial fluid accumulation in the corresponding site. The use of intravascular contrast agent enabled the sensitive detection of a minor injury by ultrasound for the first time. An intramuscular edema seen in the MRI scan showed a functional arterial perfusion impairment on ultrasound, which was

  10. A diagnostic expert system for structured reports, quality assessment, and training of residents in sonography.

    PubMed

    Huettig, Matthias; Buscher, Georg; Menzel, Thomas; Scheppach, Wolfgang; Puppe, Frank; Buscher, Hans-Peter

    2004-03-15

    The quality of medical reports on diagnostic procedures has a considerable impact on the quality of medical care. Handwritten or otherwise unstructured reports tend to be incomplete, whereas structured questionnaires are of limited flexibility and not considered case-adequate. Thus, medical reports of this kind may promote an incomplete and misleading documentation and, therefore, be problematic with respect to their reliability. SonoConsult (SC), an expert system for structured and case-adequate documentation of sonographic findings with an additional diagnostic component, was evaluated with respect to user acceptance and suitability for enhancing the quality of reports and supporting sonographic beginners. The expectations and the attitudes of the users toward the program were evaluated by anonymous questionnaires. The documentation of findings and the diagnostic conclusions in 103 free text reports made by experienced examiners were evaluated by subjecting their information to a subsequent input into SC. Free text reports were checked for information that was asked by SC but not mentioned in the reports. In a series of 150 cases, the system diagnoses were blinded during input of findings into SC-questionnaires and the examiners' diagnostic conclusions were compared with the uncovered SC-diagnoses with respect to forgotten diagnoses. The structured and data-driven acquisition of information by the program was well accepted by the users. However, only a medium interest in the system-delivered diagnoses was noted. The program-generated reports were characterized by a more detailed description of the findings and a higher number of diagnoses in comparison to the unstructured reports before introduction of SC as the only documentation system. When unaware of the system diagnoses, information was entered into the questionnaires, and SC generated some diagnoses which were not mentioned by the examiners in their conclusions. The possibility to inspect the system

  11. A pragmatic approach to sonothrombolysis in acute ischaemic stroke: the Norwegian randomised controlled sonothrombolysis in acute stroke study (NOR-SASS).

    PubMed

    Nacu, Aliona; Kvistad, Christopher E; Logallo, Nicola; Naess, Halvor; Waje-Andreassen, Ulrike; Aamodt, Anne Hege; Solhoff, Ragnar; Lund, Christian; Tobro, Håkon; Rønning, Ole Morten; Salvesen, Rolf; Idicula, Titto T; Thomassen, Lars

    2015-07-11

    Ultrasound accelerates thrombolysis with tPA (sonothrombolysis). Ultrasound in the absence of tPA also accelerates clot break-up (sonolysis). Adding intravenous gaseous microbubbles may potentiate the effect of ultrasound in both sonothrombolysis and sonolysis. The Norwegian Sonothrombolysis in Acute Stroke Study aims in a pragmatic approach to assess the effect and safety of contrast enhanced ultrasound treatment in unselected acute ischaemic stroke patients. Acute ischaemic stroke patients ≥ 18 years, with or without visible arterial occlusion on computed tomography angiography (CTA) and treatable ≤ 4(½) hours after symptom onset, are included in NOR-SASS. NOR-SASS is superimposed on a separate trial randomising patients with acute ischemic stroke to either tenecteplase or alteplase (The Norwegian Tenecteplase Stroke Trial NOR-TEST). The NOR-SASS trial has two arms: 1) the thrombolysis-arms (NOR-SASS A and B) includes patients given intravenous thrombolysis (tenecteplase or alteplase), and 2) the no-thrombolysis-arm (NOR-SASS C) includes patients with contraindications to thrombolysis. First step randomisation of NOR-SASS A is embedded in NOR-TEST as a 1:1 randomisation to either tenecteplase or alteplase. Second step NOR-SASS randomisation is 1:1 to either contrast enhanced sonothrombolysis (CEST) or sham CEST. Randomisation in NOR-SASS B (routine alteplase group) is 1:1 to either CEST or sham CEST. Randomisation of NOR-SASS C is 1:1 to either contrast enhanced sonolysis (CES) or sham CES. Ultrasound is given for one hour using a 2-MHz pulsed-wave diagnostic ultrasound probe. Microbubble contrast (SonoVue®) is given as a continuous infusion for ~30 min. Recanalisation is assessed at 60 min after start of CEST/CES. Magnetic resonance imaging and angiography is performed after 24 h of stroke onset. Primary study endpoints are 1) major neurological improvement measured with NIHSS score at 24 h and 2) favourable functional outcome defined as mRS 0-1 at 90 days

  12. A prospective comparison of procedural sedation and ultrasound-guided interscalene nerve block for shoulder reduction in the emergency department.

    PubMed

    Blaivas, Michael; Adhikari, Srikar; Lander, Lina

    2011-09-01

    Emergency physicians (EPs) are beginning to use ultrasound (US) guidance to perform regional nerve blocks. The primary objective of this study was to compare length of stay (LOS) in patients randomized to US-guided interscalene block or procedural sedation to facilitate reduction of shoulder dislocation in the emergency department (ED). The secondary objectives were to compare one-on-one health care provider time, pain experienced by the patient during reduction, and patient satisfaction between the two groups. This was a prospective, randomized study of patients presenting to the ED with shoulder dislocation. The study was conducted at an academic Level I trauma center ED with an annual census of approximately 80,000. Patients were eligible for the study if they were at least 18 years of age and required reduction of a shoulder dislocation. A convenience sample of patients was randomized to either traditional procedural sedation or US-guided interscalene nerve block. Procedural sedation was performed with etomidate as the sole agent. Interscalene blocks were performed by hospital-credentialed EPs using sterile technique and a SonoSite MicroMaxx US machine with a high-frequency linear array transducer. Categorical variables were evaluated using Fisher's exact test, and continuous variables were analyzed using the Wilcoxon rank sum test. Forty-two patients were enrolled, with 21 patients randomized to each group. The groups were not significantly different with respect to sex or age. The mean (±SD) LOS in the ED was significantly higher in the procedural sedation group (177.3 ± 37.9 min) than in the US-guided interscalene block group (100.3 ± 28.2 minutes; p < 0.0001). The mean (±SD) one-on-one health care provider time was 47.1 (±9.8) minutes for the sedation group and 5 (±0.7) minutes for the US-guided interscalene block group (p < 0.0001). There was no statistically significant difference between the two groups in patient satisfaction or pain experienced

  13. The spectroscopy analyses of PpIX by ultrasound irradiation and its sonotoxicity in vitro.

    PubMed

    Wang, Pan; Wang, Xiaobing; Zhang, Kun; Gao, Kaili; Song, Ming; Liu, Quanhong

    2013-07-01

    Protoporphyrin IX (PpIX) has been used as a sensitizer in photodynamic therapy (PDT) as well as in sonodynamic therapy (SDT). The photo-bleaching of PpIX has been well investigated in many experimental systems and some photo-products have also been identified in PDT. But until now, little information has been reported about the sono-damage of PpIX in SDT. So, the present study was to investigate changes of PpIX properties before and after different ultrasound treatment, and the potential interactions between PpIX, ultrasound and the irradiated cells. In cell-free system, the absorption and fluorescence spectra of PpIX in different solutions were measured by ultraviolet spectrometer and fluorescence spectrophotometer, respectively. The terephthalic acid dosimetry was applied to evaluate the efficiency of ultrasound cavitation by monitoring hydroxyl radical (OH) production on the thermolysis of H2O in the ultrasound field. In in vitro study, confocal microscopy was applied to detect the sub-cellular localization of PpIX in S180 cells before and after ultrasound exposure. Flow cytometry was used to detect the reactive oxygen species (ROS) generation during PpIX-SDT. MTT assay was performed to evaluate the cell viability of S180 cells after SDT treatment with or without ROS scavengers. The results show that PpIX displayed different spectral patterns in different solutions. PpIX was decomposed by ultrasound exposure as measured by the decreased absorption and fluorescence peak values in RPMI-1640 medium. In addition, the decomposition of PpIX was found to be simultaneously accompanied by OH production with increasing output power from ultrasound generator. PpIX at 1μg/ml significantly enhanced the ultrasound induced cavitation as measured by OH generation, and which was greatly eliminated by NaN3, histidine, mannitol, EDTA and catalase, but not by SOD. The in vitro study indicates more PpIX entered into S180 cells after ultrasound exposure. And, the extra-cellular Pp

  14. PREFACE: IUMRS-ICA 2008 Symposium, Sessions 'X. Applications of Synchrotron Radiation and Neutron Beam to Soft Matter Science' and 'Y. Frontier of Polymeric Nano-Soft-Materials - Precision Polymer Synthesis, Self-assembling and Their Functionalization'

    NASA Astrophysics Data System (ADS)

    Takahara, Atsushi; Kawahara, Seiichi

    2009-09-01

    Applications of Synchrotron Radiation and Neutron Beam to Soft Matter Science (Symposium X of IUMRS-ICA2008) Toshiji Kanaya, Kohji Tashiro, Kazuo Sakura Keiji Tanaka, Sono Sasaki, Naoya Torikai, Moonhor Ree, Kookheon Char, Charles C Han, Atsushi Takahara This volume contains peer-reviewed invited and contributed papers that were presented in Symposium X 'Applications of Synchrotron Radiation and Neutron Beam to Soft Matter Science' at the IUMRS International Conference in Asia 2008 (IUMRS-ICA 2008), which was held on 9-13 December 2008, at Nagoya Congress Center, Nagoya, Japan. Structure analyses of soft materials based on synchrotron radiation (SR) and neutron beam have been developed steadily. Small-angle scattering and wide-angle diffraction techniques clarified the higher-order structure as well as time dependence of structure development such as crystallization and microphase-separation. On the other hand, reflectivity, grazing-incidence scattering and diffraction techniques revealed the surface and interface structural features of soft materials. From the viewpoint of strong interests on the development of SR and neutron beam techniques for soft materials, the objective of this symposium is to provide an interdisciplinary forum for the discussion of recent advances in research, development, and applications of SR and neutron beams to soft matter science. In this symposium, 21 oral papers containing 16 invited papers and 14 poster papers from China, India, Korea, Taiwan, and Japan were presented during the three-day symposium. As a result of the review of poster and oral presentations of young scientists by symposium chairs, Dr Kummetha Raghunatha Reddy (Toyota Technological Institute) received the IUMRS-ICA 2008 Young Researcher Award. We are grateful to all invited speakers and many participants for valuable contributions and active discussions. Organizing committee of Symposium (IUMRS-ICA 2008) Professor Toshiji Kanaya (Kyoto University) Professor Kohji

  15. Aspetti deontologici e giuridici della Responsabilità professionale del chirurgo in Italia. Evoluzione storica a partire dal '900.

    PubMed

    Picardi, Nicola

    2018-01-01

    È pleonastico ricordare che ogni individuo raziocinante delle essere responsabile delle sue azioni: deve agire con la coscienza degli scopi che si propone evitando possibili conseguenze negative dei suoi atti. In ambito medico questo tipo di responsabilità è codificata con le norme della "deontologia". Per secoli l'arte terapeutica è stata praticata da individui dotati di una particolare vocazione ed una particolare cultura acquisita da Maestri dell'arte ancor prima che dalla propria esperienza, con nozioni di erboristeria e di elementari conoscenze anatomiche e di fisiologia, circondati da un'aura sacerdotale e da un rispetto derivante dal timore e dall'ammirazione per il coraggio e auspicabilmente dai successi, e facendo riferimento nell'occidente mediterraneo alle regole operative fissate nel Giuramento di Ippocrate, di significato tra il sacro ed il deontologico. Lo sviluppo delle tecniche anestesiologiche a partire dalla seconda metà dell'800 ha determinato l'ampliamento delle iniziative chirurgiche di tipo elettivo, a fianco con gli storici interventi in emergenza per la cura di lesioni traumatiche, ancor prima delle acquisizioni riguardanti le infezioni. Con l'espansione del campo di azione della chirurgia, le possibili complicanze ed i possibili insuccessi hanno fatto da contrappeso ai sentimenti di rispetto e di fiducia nei confronti dei chirurghi, giungendo a far assimilare in tali casi la loro opera quale causa all'origine di danni, provocati rientrando quindi nella categoria dei reati sottoposti alla Legge penale. Così, al termine deontologico di "responsabilità" valido per ogni iniziativa ed ogni professione, per i medici è venuto ad associarsi la qualifica di "professionale", con un significato di presunta colpevolezza. Da una parte le regole deontologiche si sono ampliate, ed hanno coinvolto direttamente il paziente nella fase decisionale delle terapie chirurgiche, formalizzate programmaticamente in moderni codici deontologici ed

  16. [Correlation analysis between biochemical and biophysical markers of endothelium damage in children with diabetes type 1].

    PubMed

    Głowińska-Olszewska, Barbara; Urban, Mirosława; Tołwińska, Joanna; Peczyńska, Jadwiga; Florys, Bozena

    2005-01-01

    Endothelial damage is one of the earliest stages in the atherosclerosis process. Adhesion molecules, secreted from dysfunctional endothelial cells are considered as early markers of atherosclerotic disease. Ultrasonographic evaluation of brachial arteries serves to detect biophysical changes in endothelial function, and evaluation of carotid arteries intima-media thickness allows to evaluate the earliest structural changes in the vessels. The aim of the study was to the evaluate levels of selected adhesion molecules (sICAM-1, sVCAM-1, sE-selectin, sP-selectin) and endothelial function with use of brachial artery dilatation study (flow mediated dilation--FMD, nitroglycerine mediated dilation--NTGMD) and IMT in carotid arteries in children and adolescents with diabetes type 1, as well as the correlation analysis between biochemical and biophysical markers of endothelial dysfunction. We studied 76 children and adolescents, with mean age--15.6+/-2.5 years, suffering from diabetes mean 7.8+/-2.8 years, mean HbA1c--8.4+/-1.5%. Control group consisted of 33 healthy children age and gender matched. Adhesion molecules levels were estimated with the use of immunoenzymatic methods (R&D Systems). Endothelial function was evaluated by study of brachial arteries dilation--FMD, NTGMD, with ultrasonographic evaluation (Hewlett Packard Sonos 4500) after Celermajer method, and IMT after Pignoli method. In the study group we found elevated levels of sICAM-1: 309.54+/-64 vs. 277.85+/-52 ng/ml in the control group (p<00.05) and elevated level of sE-selectin: 87.81+/-35 vs. 66.21+/-22 ng/ml (p<00.05). We found significantly impaired FMD in brachial arteries in the study group--7.51+/-4.52 vs. 12.61+/-4.65% (p<00.05) and significantly higher IMT value: 0.51+/-0.07 vs. 0.42+/-0.05 mm (p<00.001). Correlation analysis revealed a significant negative correlation between sE-selectin and FMD - r=-0.33 (p=0.004), and a positive correlation between E-selectin and IMT: r=0.32 (p=0.005). 1. In

  17. Characterization of Defects in Scaled Mis Dielectrics with Variable Frequency Charge Pumping

    NASA Astrophysics Data System (ADS)

    Paulsen, Ronald Eugene

    1995-01-01

    oxide trap component to the charge pumping current. Numerical simulations have been performed to support the analytical development of the generalized charge pumping model. By varying the frequency of the applied charge pumping waveform and monitoring the charge recombined per cycle, the contributions from interface traps may be separated from the contributions of the near-interface oxide traps. The generalized charge pumping model allows characterization of the density and spatial distribution of near-interface oxide traps from this variable frequency charge pumping technique. Characterization of interface and near-interface oxide trap generation has been performed on devices exposed to ionizing radiation, hot electron injection, and high -field/Fowler-Nordheim stressing. Finally, using SONOS nonvolatile memory devices, a framework has been established for experimentally determining not only the spatial distribution of near-interface oxide traps, but also the energetic distribution. An experimental approach, based on tri-level charge pumping, is discussed which allows the energetic distribution of near-interface oxide traps to be determined.

  18. Association between Obstructive Sleep Apnea and Myocardial Infarction: A Systematic Review.

    PubMed

    Porto, Fernanda; Sakamoto, Yuri Saho; Salles, Cristina

    2017-04-01

    Obstructive sleep apnea (OSA) has been associated to cardiovascular risk factors. However, the association between OSA and cardiovascular disease is still controversial. The objective of the present study was to verify the association between OSA and myocardial infarction (MI). This is a systematic review of the literature performed through electronic data sources MEDLINE/PubMed, PubMed Central, Web of Science and BVS -Biblioteca Virtual em Saúde (Virtual Health Library). The descriptors used were: 'obstructive sleep apnea' AND 'polysomnography' AND 'myocardial infarction' AND 'adults NOT 'treatment.' The present work analysed three prospective studies, selected from 142 articles. The studies followed a total sample of 5,067 OSA patients, mostly composed by male participants. All patients underwent night polysomnography, and all studies found an association between OSA and fatal and non-fatal cardiovascular outcomes. Thus, we were able to observe that 644 (12.7%) of the 5,067 patients suffered MI or stroke, or required a revascularization procedure, and 25.6% of these cardiovascular events were fatal. MI was responsible for 29.5% of all 644 analysed outcomes. There is an association between OSA and MI, in male patients, and apnea and hypopnea index (AHI) are the most reliable markers. Resumo A apneia obstrutiva do sono (AOS) tem sido associada a fatores de risco cardiovascular, porém a relação entre a AOS e doença cardiovascular ainda é controversa. O objetivo do presente estudo foi verificar a associação entre AOS e infarto do miocárdio (IM). Revisão sistemática de literatura por meio das fontes de dados eletrônicas MEDLINE/PubMed, PubMed Central, Web of Science e Biblioteca Virtual em Saúde (BVS). Os descritores utilizados foram: "obstructive sleep apnea" AND "polysomnography" AND "myocardial infarction" AND "adults" NOT "treatment".O presente trabalho analisou três estudos prospectivos, selecionados dentre 142 artigos encontrados. Os estudos

  19. Comparison of group motor control training versus individual training for people suffering from back pain.

    PubMed

    Streicher, Heike; Mätzold, Franz; Hamilton, Christine; Wagner, Petra

    2014-07-01

    This study investigated the effects of "motor-control training" (MCT) using the model of deficits in the activation of transversus abdominis (TrA) in people with recurrent back pain. The purpose of this investigation was to establish whether MCT - implemented within a new group intervention (experimental group) - is able to produce results similar to those of a conventional intervention applied individually (control group) to people suffering from back pain. Using the form of an experimental pre-post-test design, the study consisted of an experimental group (N = 18, mean age M = 45.2; SD = 18.4; 9 ♂, 9 ♀) and a comparison group (N = 13; age = 56.6; SD = 18.5; 6 ♂, 7 ♀). The training covered a period of six weeks, with two training sessions per week. The amount of training was the same in both groups. Aside from the same extent of training, the participants in the experimental group completed training content in the group interventions identical to that completed by the comparison group in the individual treatments. To clarify: The difference between the two groups was that the participants in the individual-therapy control group received individual feedback on their exercise performance and correction notes from the instructor. This degree of individual attention was not given within the group therapy. The selective activation of the M. transversus abdominis (TrA) was the main focus of the intervention, with the intent of improving its stabilising corset function, especially within the lumbar region, via increased tension of the thoracolumbar fascia. To record the progress of both groups, the anterolateral abdominal muscle recruitment of the M. transversus abdominis (TrA) was measured as a main influencing factor for anterolateral stabilisation of the spine. For measurements of muscle recruitment, rehabilitative ultrasound imaging (M-Turbo™ SonoSite(®) Erlangen in B-Mode) according to Whittaker (2007) was used. Furthermore, the relationship between pain

  20. Precipitation Estimation from Remotely Sensed Information using Artificial Neural Network-Cloud Classification System

    NASA Astrophysics Data System (ADS)

    Hong, Yang

    Precipitation estimation from satellite information (VISIBLE , IR, or microwave) is becoming increasingly imperative because of its high spatial/temporal resolution and board coverage unparalleled by ground-based data. After decades' efforts of rainfall estimation using IR imagery as basis, it has been explored and concluded that the limitations/uncertainty of the existing techniques are: (1) pixel-based local-scale feature extraction; (2) IR temperature threshold to define rain/no-rain clouds; (3) indirect relationship between rain rate and cloud-top temperature; (4) lumped techniques to model high variability of cloud-precipitation processes; (5) coarse scales of rainfall products. As continuing studies, a new version of Precipitation Estimation from Remotely Sensed Information using Artificial Neural Network (PERSIANN), called Cloud Classification System (CCS), has been developed to cope with these limitations in this dissertation. CCS includes three consecutive components: (1) a hybrid segmentation algorithm, namely Hierarchically Topographical Thresholding and Stepwise Seeded Region Growing (HTH-SSRG), to segment satellite IR images into separated cloud patches; (2) a 3D feature extraction procedure to retrieve both pixel-based local-scale and patch-based large-scale features of cloud patch at various heights; (3) an ANN model, Self-Organizing Nonlinear Output (SONO) network, to classify cloud patches into similarity-based clusters, using Self-Organizing Feature Map (SOFM), and then calibrate hundreds of multi-parameter nonlinear functions to identify the relationship between every cloud types and their underneath precipitation characteristics using Probability Matching Method and Multi-Start Downhill Simplex optimization techniques. The model was calibrated over the Southwest of United States (100°--130°W and 25°--45°N) first and then adaptively adjusted to the study region of North America Monsoon Experiment (65°--135°W and 10°--50°N) using

  1. Assessment of peripheral skeletal muscle microperfusion in a porcine model of peripheral arterial stenosis by steady-state contrast-enhanced ultrasound and Doppler flow measurement.

    PubMed

    Naehle, Claas P; Steinberg, Verena A; Schild, Hans; Mommertz, Gottfried

    2015-05-01

    Noninvasive measurement of peripheral muscle microperfusion could potentially improve diagnosis, management, and treatment of peripheral arterial disease (PAD) and thus improve patient care. Contrast-enhanced ultrasound (CEUS) as a noninvasive diagnostic tool allows quantification of muscle perfusion. Increasing data on bolus technique CEUS reflecting microperfusion are becoming available, but only limited data on steady-state CEUS for assessment of muscle microperfusion are available. Therefore, the aim of this study was to evaluate steady-state CEUS for assessment of peripheral muscle microperfusion in a PAD animal model. In a porcine animal model, peripheral muscle microperfusion was quantified by steady-state CEUS replenishment kinetics (mean transit time [mTT] and wash-in rate [WiR]) of the biceps femoris muscle during intravenous steady-state infusion of INN-sulfur hexafluoride (SonoVue; Bracco, Geneva, Switzerland). In addition, macroperfusion was quantified at the external femoral artery with a Doppler flow probe. Peripheral muscle microperfusion and Doppler flow measurements were performed bilaterally at rest and under adenosine stress (70 μg/kg body weight) before and after unilateral creation of a moderate external iliac artery stenosis. All measurements could be performed completely in 10 pigs. Compared with baseline measurements, peripheral muscle microperfusion decreased significantly during adenosine stress (rest vs adenosine stress: mTT, 7.8 ± 3.3 vs 21.2 ± 17.8 s, P = .0006; WiR, 58.4 ± 38.1 vs 25.3 ± 15.6 arbitrary units [a.u.]/s, P < .0001; Doppler flow, 122.3 ± 31.4 vs 83.6 ± 28.1 mL/min, P = .0067) and after stenosis creation (no stenosis vs stenosis: mTT, 8.1 ± 3.1 vs 29.2 ± 18.0 s, P = .0469; WiR, 53.0 ± 22.7 vs 13.6 ± 8.4 a.u./s, P = .0156; Doppler flow, 124.2 ± 41.8 vs 65.9 ± 40.0 mL/min, P = .0313). After stenosis creation, adenosine stress led to a further significant decrease of peripheral muscle microperfusion but had no

  2. Advanced Materials and Processing 2010

    NASA Astrophysics Data System (ADS)

    Zhang, Yunfeng; Su, Chun Wei; Xia, Hui; Xiao, Pengfei

    2011-06-01

    Strain sensors made from MWNT/polymer nanocomposites / Gang Yin, Ning Hu and Yuan Li -- Shear band evolution and nanostructure formation in titanium by cold rolling / Dengke Yang, Peter D. Hodgson and Cuie Wen -- Biodegradable Mg-Zr-Ca alloys for bone implant materials / Yuncang Li ... [et al.] -- Hydroxyapatite synthesized from nanosized calcium carbonate via hydrothermal method / Yu-Shiang Wu, Wen-Ku Chang and Min Jou -- Modeling of the magnetization process and orthogonal fluxgate sensitivity of ferromagnetic micro-wire arrays / Fan Jie ... [et al.] -- Fabrication of silicon oxide nanowires on Ni coated silicon substrate by simple heating process / Bo Peng and Kwon-Koo Cho -- Deposition of TiOxNy thin films with various nitrogen flow rate: growth behavior and structural properties / S.-J. Cho ... [et al.] -- Observation on photoluminescence evolution in 300 KeV self-ion implanted and annealed silicon / Yu Yang ... [et al.] -- Facile synthesis of lithium niobate from a novel precursor H[symbol] / Meinan Liu ... [et al.] -- Effects of the buffer layers on the adhesion and antimicrobial properties of the amorphous ZrAlNiCuSi films / Pai-Tsung Chiang ... [et al.] -- Fabrication of ZnO nanorods by electrochemical deposition process and its photovoltaic properties / Jin-Hwa Kim ... [et al.] -- Cryogenic resistivities of NbTiAlVTaLax, CoCrFeNiCu and CoCrFeNiAl high entropy alloys / Xiao Yang and Yong Zhang -- Modeling of centrifugal force field and the effect on filling and solidification in centrifugal casting / Wenbin Sheng, Chunxue Ma and Wanli Gu -- Electrochemical properties of TiO[symbol] nanotube arrays film prepared by anodic oxidation / Young-Jin Choi ... [et al.] -- Effect of Ce additions on high temperature properties of Mg-5Sn-3Al-1Zn alloy / Byoung Soo Kang ... [et al.] -- Sono-electroless plating of Ni-Mo-P film / Atsushi Chiba, Masato Kanou and Wen-Chang Wu -- Diameter dependence of giant magneto-impedance effect in co-based melt extracted amorphous